Sample records for passive control measures

  1. The passive control of air pollution exposure in Dublin, Ireland: a combined measurement and modelling case study.

    PubMed

    Gallagher, J; Gill, L W; McNabola, A

    2013-08-01

    This study investigates the potential real world application of passive control systems to reduce personal pollutant exposure in an urban street canyon in Dublin, Ireland. The implementation of parked cars and/or low boundary walls as a passive control system has been shown to minimise personal exposure to pollutants on footpaths in previous investigations. However, previous research has been limited to generic numerical modelling studies. This study combines real-time traffic data, meteorological conditions and pollution concentrations, in a real world urban street canyon before and after the implementation of a passive control system. Using a combination of field measurements and numerical modelling this study assessed the potential impact of passive controls on personal exposure to nitric oxide (NO) concentrations in the street canyon in winter conditions. A calibrated numerical model of the urban street canyon was developed, taking into account the variability in traffic and meteorological conditions. The modelling system combined the computational fluid dynamic (CFD) simulations and a semi-empirical equation, and demonstrated a good agreement with measured field data collected in the street canyon. The results indicated that lane distribution, fleet composition and vehicular turbulence all affected pollutant dispersion, in addition to the canyon geometry and local meteorological conditions. The introduction of passive controls displayed mixed results for improvements in air quality on the footpaths for different wind and traffic conditions. Parked cars demonstrated the most comprehensive passive control system with average improvements in air quality of up to 15% on the footpaths. This study highlights the potential of passive controls in a real street canyon to increase dispersion and improve air quality at street level. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Concern about passive smoking and tobacco control policies in European countries: An ecological study

    PubMed Central

    2012-01-01

    Background Because of the magnitude of the global tobacco epidemic, the World Health Organisation developed the Framework Convention on Tobacco Control (FCTC), an international legally binding treaty to control tobacco use. Adoption and implementation of specific tobacco control measures within FCTC is an outcome of a political process, where social norms and public opinion play important roles. The objective of our study was to examine how a country’s level of tobacco control is associated with smoking prevalence, two markers of denormalisation of smoking (social disapproval of smoking and concern about passive smoking), and societal support for tobacco control. Methods An ecological study was conducted, using data from two sources. The first source was the Tobacco Control Scale (TCS) from 2011, which quantifies the implementation of tobacco control policies in European Union (EU) countries. Data on smoking prevalence, societal disapproval of smoking, concern about passive smoking, and societal support for policy measures were taken from the Eurobarometer survey of 2009. Data from Eurobarometer surveys were aggregated to country level. Data from the 27 European Union member states were used. Results Smoking prevalence rates in 2009 were negatively associated with a country’s TCS 2011 score, although not statistically significant (r = −.25; p = .21). Experience of societal disapproval was positively associated with higher TCS scores, though not significantly (r = .14; p = .48). The same was true for societal support for tobacco control (r = .27; p = .18). The TCS score in 2011 was significantly correlated with concern about passive smoking (r = .42; p =.03). Support for tobacco control measures was also strongly correlated with concern about passive smoking (r = .52, p = .006). Conclusions Smokers in countries with a higher TCS score were more concerned about whether their smoke harms others. Further, support for tobacco control measures is higher in countries that have more of these concerned smokers. Concerns about passive smoking seem central in the implementation of tobacco control measures, stressing the importance of continuing to educate the public about the harm from passive smoking. PMID:23067145

  3. Anti-collision radio-frequency identification system using passive SAW tags

    NASA Astrophysics Data System (ADS)

    Sorokin, A. V.; Shepeta, A. P.

    2017-06-01

    Modern multi sensor systems should have high operating speed and resistance to climate impacts. Radiofrequency systems use passive SAW tags for identification items and vehicles. These tags find application in industry, traffic remote control systems, and railway remote traffic control systems for identification and speed measuring. However, collision of the passive SAW RFID tags hinders development passive RFID SAW technology in Industry. The collision problem for passive SAW tags leads for incorrect identification and encoding each tag. In our researching, we suggest approach for identification of several passive SAW tags in collision case.

  4. Surface passivation and aging of InGaAs/InP heterojunction phototransistors

    NASA Astrophysics Data System (ADS)

    Park, Min-Su; Razaei, Mohsen; Barnhart, Katie; Tan, Chee Leong; Mohseni, Hooman

    2017-06-01

    We report the effect of different surface treatment and passivation techniques on the stability of InGaAs/InP heterojunction phototransistors (HPTs). An In0.53Ga0.47As surface passivated with aqueous ammonium sulfide ((NH4)2S), aluminum oxide (Al2O3) grown by atomic layer deposition (ALD), and their combination is evaluated by using Raman spectroscopy and X-ray photoelectron spectroscopy (XPS). All samples were kept in the air ambient, and their performances were periodically measured to investigate their long-term stability. Raman spectroscopy revealed that the peak intensity of the GaAs-like longitudinal optical phonon of all passivated samples is decreased compared with that of the control sample. This is attributable to the diminution of the carriers near the passivated surfaces, which was proven by extracted surface potential (Vs). The Vs of all passivated samples was decreased to less than half of that for the control sample. XPS evaluation of As3d spectra showed that arsenic oxides (As2O3 and As2O5) on the surfaces of the samples can be removed by passivation. However, both Raman and XPS spectra show that the (NH4)2S passivated sample reverts back over time and will resemble the untreated control sample. When capped with ALD-grown Al2O3, passivated samples irrespective of the pretreatment show no degradation over the measured time of 4 weeks. Similar conclusions are made from our experimental measurement of the performance of differently passivated HPTs. The ALD-grown Al2O3 passivated devices show an improved optical gain at low optical powers and long-term stability.

  5. A randomized controlled trial for the effect of passive stretching on measures of hamstring extensibility, passive stiffness, strength, and stretch tolerance.

    PubMed

    Marshall, Paul W M; Cashman, Anthony; Cheema, Birinder S

    2011-11-01

    To measure hamstring extensibility, stiffness, stretch tolerance, and strength following a 4-week passive stretching program. Randomized controlled trial. Twenty-two healthy participants were randomly assigned to either a 4-week stretching program consisting of 4 hamstring and hip stretches performed 5 times per week, or a non-stretching control group. Hamstring extensibility and stiffness were measured before and after training using the instrumented straight leg raise test (iSLR). Stretch tolerance was measured as the pain intensity (visual analog scale; VAS) elicited during the maximal stretch. Hamstring strength was measured using isokinetic dynamometry at 30 and 120° s(-1). Hamstring extensibility increased by 20.9% in the intervention group following 4 weeks of training (p<0.001; d=0.86). Passive stiffness was reduced by 31% in the intervention group (p<0.05; d=-0.89). Stretch tolerance VAS scores were not different between groups at either time point, and no changes were observed following training. There were no changes in hamstring concentric strength measured at 30 and 120° s(-1). Passive stretching increases hamstring extensibility and decreases passive stiffness, with no change in stretch tolerance defined by pain intensity during the stretch. Compared to previous research, the volume of stretching was higher in this study. The volume of prescribed stretching is important for eliciting the strong clinical effect observed in this study. Copyright © 2011 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  6. Field intercomparison of ammonia passive samplers: results and lessons learned.

    NASA Astrophysics Data System (ADS)

    Stephens, Amy; Leeson, Sarah; Jones, Matthew; van Dijk, Netty; Kentisbeer, John; Twigg, Marsailidh; Simmons, Ivan; Braban, Christine; Martin, Nick; Poskitt, Janet; Ferm, Martin; Seitler, Eva; Sacco, Paolo; Gates, Linda; Stolk, Ariën; Stoll, Jean-Marc; Tang, Sim

    2017-04-01

    Ammonia pollution contributes significantly to eutrophication and acidification of ecosystems with resultant losses of biodiversity and ecosystem changes. Monitoring of ambient ammonia over a wide spatial and long temporal scales is primarily done with low-cost diffusive samplers. Less frequently, surface flux measurements of ammonia can be made using passive samplers at plot scale. This paper will present a field intercomparison conducted within the MetNH3 project to assess the performance of passive samplers for ambient measurements of ammonia. Eight different designs of commercial passive samplers housed in shelters provided by the manufacturer/laboratory were exposed over an 8-week period at the Whim experimental field site in Scotland between August and October 2016. Whim Bog has a facility in place for controlled releases of ammonia (http://www.whimbog.ceh.ac.uk/). Automated conditional release from the line source occurs when the wind direction in the preceding minute is from the northeast (wind sector 180-215°) and wind speed is > 5 m s-1. The passive samplers were exposed at different distances from the release source (16, 32 and 60 m) and also at a background location. Most were exposed for 2 x 4-week long periods and some for 4 x 2-week long periods. At the 32 m position, an active denuder method, the CEH DELTA sampler and a continuous high temporal resolution wet chemistry ammonia instrument (AiRRmonia, Mechatronics, NL.) were also deployed alongside the passive samplers to provide reference measurements of ammonia. Results are presented within the context of the MetNH3 CATFAC controlled laboratory exposure assessments. The results are discussed in terms of typical deployments of passive samplers and quality control. Measurement for policy evidence for both local and regional studies using passive samplers are discussed.

  7. Active and passive vibration suppression for space structures

    NASA Technical Reports Server (NTRS)

    Hyland, David C.

    1991-01-01

    The relative benefits of passive and active vibration suppression for large space structures (LSS) are discussed. The intent is to sketch the true ranges of applicability of these approaches using previously published technical results. It was found that the distinction between active and passive vibration suppression approaches is not as sharp as might be thought at first. The relative simplicity, reliability, and cost effectiveness touted for passive measures are vitiated by 'hidden costs' bound up with detailed engineering implementation issues and inherent performance limitations. At the same time, reliability and robustness issues are often cited against active control. It is argued that a continuum of vibration suppression measures offering mutually supporting capabilities is needed. The challenge is to properly orchestrate a spectrum of methods to reap the synergistic benefits of combined advanced materials, passive damping, and active control.

  8. Shaking table experimentation on adjacent structures controlled by passive and semi-active MR dampers

    NASA Astrophysics Data System (ADS)

    Basili, M.; De Angelis, M.; Fraraccio, G.

    2013-06-01

    This paper presents the results of shaking table tests on adjacent structures controlled by passive and semi-active MR dampers. The aim was to demonstrate experimentally the effectiveness of passive and semi-active strategies in reducing structural vibrations due to seismic excitation. The physical model at issue was represented by two adjacent steel structures, respectively of 4 and 2 levels, connected at the second level by a MR damper. When the device operated in semi-active mode, an ON-OFF control algorithm, derived by the Lyapunov stability theory, was implemented and experimentally validated. Since the experimentation concerned adjacent structures, two control objectives have been reached: global and selective protection. In case of global protection, the attention was focused on protecting both structures, whereas, in case of selective protection, the attention was focused on protecting only one structure. For each objective the effectiveness of passive control has been compared with the situation of no control and then the effectiveness of semi-active control has been compared with the passive one. The quantities directly compared have been: measured displacements, accelerations and force-displacement of the MR damper, moreover some global response quantities have been estimated from experimental measures, which are the base share force and the base bending moment, the input energy and the energy dissipated by the device. In order to evaluate the effectiveness of the control action in both passive and semi-active case, an energy index EDI, previously defined and already often applied numerically, has been utilized. The aspects investigated in the experimentation have been: the implementation and validation of the control algorithm for selective and global protection, the MR damper input voltage influence, the kind of seismic input and its intensity.

  9. [A cross sectional study of passive smoking of non-smoking women and analysis of influence factors on women passive smoking].

    PubMed

    Han, Jing-Xiu; Ma, Ling; Zhang, Hong-Wei; Liu, Xi; Zheng, Su-hua; Gan, De-kun; Fang, Jun

    2006-09-01

    To fund out the state of passive smoking of non-smoking women and search for measures of controlling women passive smoking. 3500 non-smoking women in Beijing, Shanghai, Chengdu city were interviewed. Analyses were performed by chi2 test Fisher test and ANOVA test. 92.7% passive smoking women exposure to ETS at home, 40.8% at workplace. 38.9% exposed to ETS from birthday, and 42.3% from 18 - 30 age. The average exposure time of passive smoking is (1.17 +/- 1.10) hours per day. The proportion of passive-smoking time over 2 hours at home is higher than work place. In passive-smoking group, the proportion of 30 - 50 age group, secondary education, married, merchant/service, principal of units, and manufacture/transport workers were higher than non-smoking group. 97.5% think that passive smoking is harmful to health, and the proportion of thinking passive smoking has severe harm to health in non-passive-smoking group is higher than passive-smoking group. 70.0% open windows when someone smokes around her, but only 16.9% ask the smokers do not smoke around her forwardly. Suppose that someone were smoking around yourself, the consciousness of avoiding passive smoking forwardly in non-passive-smoking group is stronger than passive-smoking group. 95.1% believe the content of smoking-harm propagandized by medium. The main places of controlling passive smoking are the home and the department, commerce, service, and manufacture/ transport workplace. The rate of passive smoking was influenced by the consciousness of the serious level of harms by passive smoking. Propagandizing the serious harm of passive smoking by medium and strengthening the consciousness of avoiding passive smoking were one of feasible measures to lower the rate of smoking and passive smoking.

  10. Passive stiffness of the gastrocnemius muscle in athletes with spastic hemiplegic cerebral palsy.

    PubMed

    Hussain, A W; Onambele, G L; Williams, A G; Morse, C I

    2013-09-01

    The passive properties of the muscle-tendon unit are regularly assessed in individuals with cerebral palsy (CP). However, no information is available on the passive properties of adult muscle, and whether any differences exist between the paretic and control muscles. Eleven ambulant male athletes with spastic hemiplegic CP (21.2 ± 3.0 years) and controls without neurological impairment (age = 21.8 ± 2.2 years) completed two and one passive stretch session, respectively. During each session, the ankle was passively dorsiflexed until end range of motion (ROM), whilst recording passive ankle angle, torque and gastrocnemius medialis (GM) myotendinous junction (MTJ) displacement. In addition, GM cross-sectional area (CSA) and length were measured. Subsequently, in vivo stress and strain were determined to calculate elastic modulus. Passive stiffness, MTJ displacement and ROM of the paretic GM were not different from the control muscles. However, the elastic modulus of the paretic GM was two times stiffer than the control GM muscles. In conclusion, athletes with CP exhibit absolute passive muscle stiffness similar to the controls; however, the elastic modulus of the CP muscle was significantly greater. Therefore, throughout the same ROM a smaller GM CSA in CP athletes has to dissipate larger relative torque compared to the control muscles, consequently causing the muscle to elongate to the same extent as the non-paretic muscle under stretch.

  11. Performance of Passive Samplers Analyzed by Computer-Controlled Scanning Electron Microscopy to Measure PM10-2.5.

    PubMed

    Peters, Thomas M; Sawvel, Eric J; Willis, Robert; West, Roger R; Casuccio, Gary S

    2016-07-19

    We report on the precision and accuracy of measuring PM10-2.5 and its components with particles collected by passive aerosol samplers and analyzed by computer-controlled scanning electron microscopy with energy dispersive X-ray spectroscopy. Passive samplers were deployed for week-long intervals in triplicate and colocated with a federal reference method sampler at three sites and for 5 weeks in summer 2009 and 5 weeks in winter 2010 in Cleveland, OH. The limit of detection of the passive method for PM10-2.5 determined from blank analysis was 2.8 μg m(-3). Overall precision expressed as root-mean-square coefficient of variation (CVRMS) improved with increasing concentrations (37% for all samples, n = 30; 19% for PM10-2.5 > 10 μg m(-3), n = 9; and 10% for PM10-2.5 > 15 μg m(-3), n = 4). The linear regression of PM10-2.5 measured passively on that measured with the reference sampler exhibited an intercept not statistically different than zero (p = 0.46) and a slope not statistically different from unity (p = 0.92). Triplicates with high CVs (CV > 40%, n = 5) were attributed to low particle counts (and mass concentrations), spurious counts attributed to salt particles, and Al-rich particles. This work provides important quantitative observations that can help guide future development and use of passive samplers for measuring atmospheric particulate matter.

  12. Influence of Passive Stiffness of Hamstrings on Postural Stability

    PubMed Central

    Kuszewski, Michał; Gnat, Rafał; Sobota, Grzegorz; Myśliwiec, Andrzej

    2015-01-01

    The aim of the study was to explore whether passive stiffness of the hamstrings influences the strategy of maintaining postural stability. A sample of 50 subjects was selected; the final analyses were based on data of 41 individuals (33 men, 8 women) aged 21 to 29 (mean = 23.3, SD = 1.1) years. A quasi- experimental ex post facto design with repeated measures was used. Categories of independent variables were obtained directly prior to the measurement of the dependent variables. In stage one of the study, passive knee extension was measured in the supine position to assess hamstring stiffness. In stage two, the magnitude of postural sway in antero-posterior direction was measured, while varying the body position on a stabilometric platform, both with and without visual control. The margin of safety was used as a measure of postural control. The magnitude of the margin of safety increased significantly between the open-eye and closed-eye trials. However, although we registered a visible tendency for a larger increase of the margin of safety associated with lower levels of passive hamstrings stiffness, no significant differences were found. Therefore, this study demonstrated that hamstring stiffness did not influence the strategy used to maintain postural stability. PMID:25964809

  13. Influence of passive stiffness of hamstrings on postural stability.

    PubMed

    Kuszewski, Michał; Gnat, Rafał; Sobota, Grzegorz; Myśliwiec, Andrzej

    2015-03-29

    The aim of the study was to explore whether passive stiffness of the hamstrings influences the strategy of maintaining postural stability. A sample of 50 subjects was selected; the final analyses were based on data of 41 individuals (33 men, 8 women) aged 21 to 29 (mean = 23.3, SD = 1.1) years. A quasi- experimental ex post facto design with repeated measures was used. Categories of independent variables were obtained directly prior to the measurement of the dependent variables. In stage one of the study, passive knee extension was measured in the supine position to assess hamstring stiffness. In stage two, the magnitude of postural sway in antero-posterior direction was measured, while varying the body position on a stabilometric platform, both with and without visual control. The margin of safety was used as a measure of postural control. The magnitude of the margin of safety increased significantly between the open-eye and closed-eye trials. However, although we registered a visible tendency for a larger increase of the margin of safety associated with lower levels of passive hamstrings stiffness, no significant differences were found. Therefore, this study demonstrated that hamstring stiffness did not influence the strategy used to maintain postural stability.

  14. Mixed H∞ and passive control for linear switched systems via hybrid control approach

    NASA Astrophysics Data System (ADS)

    Zheng, Qunxian; Ling, Youzhu; Wei, Lisheng; Zhang, Hongbin

    2018-03-01

    This paper investigates the mixed H∞ and passive control problem for linear switched systems based on a hybrid control strategy. To solve this problem, first, a new performance index is proposed. This performance index can be viewed as the mixed weighted H∞ and passivity performance. Then, the hybrid controllers are used to stabilise the switched systems. The hybrid controllers consist of dynamic output-feedback controllers for every subsystem and state updating controllers at the switching instant. The design of state updating controllers not only depends on the pre-switching subsystem and the post-switching subsystem, but also depends on the measurable output signal. The hybrid controllers proposed in this paper can include some existing ones as special cases. Combine the multiple Lyapunov functions approach with the average dwell time technique, new sufficient conditions are obtained. Under the new conditions, the closed-loop linear switched systems are globally uniformly asymptotically stable with a mixed H∞ and passivity performance index. Moreover, the desired hybrid controllers can be constructed by solving a set of linear matrix inequalities. Finally, a numerical example and a practical example are given.

  15. Eigenvalue assignment strategies in rotor systems

    NASA Technical Reports Server (NTRS)

    Youngblood, J. N.; Welzyn, K. J.

    1986-01-01

    The work done to establish the control and direction of effective eigenvalue excursions of lightly damped, speed dependent rotor systems using passive control is discussed. Both second order and sixth order bi-axis, quasi-linear, speed dependent generic models were investigated. In every case a single, bi-directional control bearing was used in a passive feedback stabilization loop to resist modal destabilization above the rotor critical speed. Assuming incomplete state measurement, sub-optimal control strategies were used to define the preferred location of the control bearing, the most effective measurement locations, and the best set of control gains to extend the speed range of stable operation. Speed dependent control gains were found by Powell's method to maximize the minimum modal damping ratio for the speed dependent linear model. An increase of 300 percent in stable speed operation was obtained for the sixth order linear system using passive control. Simulations were run to examine the effectiveness of the linear control law on nonlinear rotor models with bearing deadband. The maximum level of control effort (force) required by the control bearing to stabilize the rotor at speeds above the critical was determined for the models with bearing deadband.

  16. Measurement of the passive stiffness of ankle joint in 3 DOF using stewart platform type ankle foot device.

    PubMed

    Nomura, Kenta; Yonezawa, Teru; Mizoguchi, Hiroshi; Takemura, Hiroshi

    2016-08-01

    This paper presents a method to measure the passive stiffness of an ankle joint in three degrees of freedom (DOF) under two motion speeds (1 Hz and 5 degree/s) using a developed Stewart platform-type device. The developed device can reproduce input motions of the foot in 6 DOF by controlling six pneumatic linear motion actuators. We used the device to measure the passive stiffness of an ankle joint undergoing three kinds of motion, namely dorsi-plantar flexion, inversion-eversion, and adduction-abduction. The measured values of the passive stiffness of the ankle joint in dorsiflexion that we obtained agreed well with that obtained in a previous study, indicating that the developed device is useful for measuring the passive stiffness of ankle joint. In addition, the developed device can be used to measure the stiffness in inversion-eversion and adduction-abduction motions as well, parameters that have never been measured. The results we obtained demonstrated certain interesting features as we varied both the direction and pace of motion (e.g., there were significant differences in the stiffness not only between adduction and abduction during the faster pace, but also between these and the other motions).

  17. Active controllers and the time duration to learn a task

    NASA Technical Reports Server (NTRS)

    Repperger, D. W.; Goodyear, C.

    1986-01-01

    An active controller was used to help train naive subjects involved in a compensatory tracking task. The controller is called active in this context because it moves the subject's hand in a direction to improve tracking. It is of interest here to question whether the active controller helps the subject to learn a task more rapidly than the passive controller. Six subjects, inexperienced to compensatory tracking, were run to asymptote root mean square error tracking levels with an active controller or a passive controller. The time required to learn the task was defined several different ways. The results of the different measures of learning were examined across pools of subjects and across controllers using statistical tests. The comparison between the active controller and the passive controller as to their ability to accelerate the learning process as well as reduce levels of asymptotic tracking error is reported here.

  18. Motor vehicle driver injury severity study under various traffic control at highway-rail grade crossings in the United States.

    PubMed

    Hao, Wei; Daniel, Janice

    2014-12-01

    Based on the Federal Railway Administration (FRA) database, approximately 62% of the collisions at highway-rail crossings occurred at locations with active controls (gate and flashing lights), followed by passive controls (cross bucks and stop signs) with approximately 28% of accidents. The study applied an ordered probit model to explore the determinants of driver injury severity under various control measures at highway-rail grade crossing in the United States. The analysis found that schedule factor (peak hour), visibility, motor vehicle speed, train speed, driver's age, area type, traffic volume and highway pavement impact driver injury severity at both active and passive highway-rail crossings. For both active and passive control highway-rail grade crossings, speed control for both trains and vehicles will significantly reduce driver injury severity. However, the level of influence by vehicle speed and train speed at passive control is higher compared with active control. Paving highways at highway-rail grade crossings will also help to reduce driver injury severity at highway-rail crossing accidents. Published by Elsevier Ltd.

  19. Effects of ipsilateral anterior thigh soft tissue stretching on passive unilateral straight-leg raise.

    PubMed

    Clark, S; Christiansen, A; Hellman, D F; Hugunin, J W; Hurst, K M

    1999-01-01

    Randomized 3-group pretest-posttest with blind assessment of outcome. The purpose of this study was to examine the effect of sagittal plane hold-relax exercise applied to the ipsilateral anterior thigh, and prone positioning on passive unilateral straight-leg raise measurements. Straight-leg raising has been viewed as a measurement for hamstring muscle length, but literature suggests that other structures may affect this measurement. Sixty subjects (45 men, 15 women) qualified for inclusion into the study based on a straight-leg raise measurement of < or = 65 degrees. Subjects were randomly assigned to one of three groups: control, static stretch, or sagittal plane hold-relax exercise. Pretest and posttest straight-leg raise measurements of the right lower extremity were performed for each subject. A 1-way ANOVA of the change scores showed a significant difference between groups. A Tukey post hoc analysis of the change scores showed that both treatment groups' means differed significantly from the control group and from each other, with the sagittal plane hold-relax group exhibiting the largest change (mean of 7.8 degrees +/- 2.8 degrees). The results of this study show that sagittal plane hold-relax exercise and passive prone results of this study show that sagittal plane hold-relax and passive prone positioning can significantly increase straight-leg raise range of motion, however the sagittal plane hold-relax stretching of the anterior thigh is more effective than passive prone positioning.

  20. Design for active and passive flutter suppression and gust alleviation. Ph.D. Thesis

    NASA Technical Reports Server (NTRS)

    Karpel, M.

    1981-01-01

    Analytical design techniques for active and passive control of aeroelastic systems are based on a rational approximation of the unsteady aerodynamic loads in the entire Laplace domain, which yields matrix equations of motion with constant coefficients. Some existing schemes are reviewed, the matrix Pade approximant is modified, and a technique which yields a minimal number of augmented states for a desired accuracy is presented. The state-space aeroelastic model is used to design an active control system for simultaneous flutter suppression and gust alleviation. The design target is for a continuous controller which transfers some measurements taken on the vehicle to a control command applied to a control surface. Structural modifications are formulated in a way which enables the treatment of passive flutter suppression system with the same procedures by which active control systems are designed.

  1. Operation of passive membrane systems for drinking water treatment.

    PubMed

    Oka, P A; Khadem, N; Bérubé, P R

    2017-05-15

    The widespread adoption of submerged hollow fibre ultrafiltration (UF) for drinking water treatment is currently hindered by the complexity and cost of these membrane systems, especially in small/remote communities. Most of the complexity is associated with auxiliary fouling control measures, which include backwashing, air sparging and chemical cleaning. Recent studies have demonstrated that sustained operation without fouling control measures is possible, but little is known regarding the conditions under which extended operation can be sustained with minimal to no fouling control measures. The present study investigated the contribution of different auxiliary fouling control measures to the permeability that can be sustained, with the intent of minimizing the mechanical and operational complexity of submerged hollow fiber UF membrane systems while maximizing their throughput capacity. Sustained conditions could be achieved without backwashing, air sparging or chemical cleaning (i.e. passive operation), indicating that these fouling control measures can be eliminated, substantially simplifying the mechanical and operational complexity of submerged hollow fiber UF systems. The adoption of hydrostatic pressure (i.e. gravity) to provide the driving force for permeation further reduced the system complexity. Approximately 50% of the organic material in the raw water was removed during treatment. The sustained passive operation and effective removal of organic material was likely due to the microbial community that established itself on the membrane surface. The permeability that could be sustained was however only approximately 20% of that which can be maintained with fouling control measures. Retaining a small amount of air sparging (i.e. a few minutes daily) and incorporating a daily 1-h relaxation (i.e. permeate flux interruption) period prior to sparging more than doubled the permeability that could be sustained. Neither the approach used to interrupt the permeate flux nor that developed to draw air into the system for sparging using gravity add substantial mechanical or operational complexity to the system. The high throughput capacity that can be sustained by eliminating all but a couple of simple fouling control measures make passive membrane systems ideally suited to provide high quality water especially where access to financial resources, technical expertise and/or electrical power is limited. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Immediate effect of passive and active stretching on hamstrings flexibility: a single-blinded randomized control trial.

    PubMed

    Nishikawa, Yuichi; Aizawa, Junya; Kanemura, Naohiko; Takahashi, Tetsuya; Hosomi, Naohisa; Maruyama, Hirofumi; Kimura, Hiroaki; Matsumoto, Masayasu; Takayanagi, Kiyomi

    2015-10-01

    [Purpose] This study compared the efficacy of passive and active stretching techniques on hamstring flexibility. [Subjects] Fifty-four healthy young subjects were randomly assigned to one of three groups (2 treatment groups and 1 control group). [Methods] Subjects in the passive stretching group had their knees extended by an examiner while lying supine 90° of hip flexion. In the same position, subjects in the active stretching group extended their knees. The groups performed 3 sets of the assigned stretch, with each stretch held for 10 seconds at the point where tightness in the hamstring muscles was felt. Subjects in the control group did not perform stretching. Before and immediately after stretching, hamstring flexibility was assessed by a blinded assessor, using the active knee-extension test. [Results] After stretching, there was a significant improvement in the hamstring flexibilities of the active and passive stretching groups compared with the control group. Furthermore, the passive stretching group showed significantly greater improvement in hamstring flexibility than the active stretching group. [Conclusion] Improvement in hamstring flexibility measured by the active knee-extension test was achieved by both stretching techniques; however, passive stretching was more effective than active stretching at achieving an immediate increase in hamstring flexibility.

  3. Energetic Passivity of the Human Ankle Joint.

    PubMed

    Lee, Hyunglae; Hogan, Neville

    2016-12-01

    Understanding the passive or nonpassive behavior of the neuromuscular system is important to design and control robots that physically interact with humans, since it provides quantitative information to secure coupled stability while maximizing performance. This has become more important than ever apace with the increasing demand for robotic technologies in neurorehabilitation. This paper presents a quantitative characterization of passive and nonpassive behavior of the ankle of young healthy subjects, which provides a baseline for future studies in persons with neurological impairments and information for future developments of rehabilitation robots, such as exoskeletal devices and powered prostheses. Measurements using a wearable ankle robot actuating 2 degrees-of-freedom of the ankle combined with curl analysis and passivity analysis enabled characterization of both quasi-static and steady-state dynamic behavior of the ankle, unavailable from single DOF studies. Despite active neuromuscular control over a wide range of muscle activation, in young healthy subjects passive or dissipative ankle behavior predominated.

  4. Folding in and out: passive morphing in flapping wings.

    PubMed

    Stowers, Amanda K; Lentink, David

    2015-03-25

    We present a new mechanism for passive wing morphing of flapping wings inspired by bat and bird wing morphology. The mechanism consists of an unactuated hand wing connected to the arm wing with a wrist joint. Flapping motion generates centrifugal accelerations in the hand wing, forcing it to unfold passively. Using a robotic model in hover, we made kinematic measurements of unfolding kinematics as functions of the non-dimensional wingspan fold ratio (2-2.5) and flapping frequency (5-17 Hz) using stereo high-speed cameras. We find that the wings unfold passively within one to two flaps and remain unfolded with only small amplitude oscillations. To better understand the passive dynamics, we constructed a computer model of the unfolding process based on rigid body dynamics, contact models, and aerodynamic correlations. This model predicts the measured passive unfolding within about one flap and shows that unfolding is driven by centrifugal acceleration induced by flapping. The simulations also predict that relative unfolding time only weakly depends on flapping frequency and can be reduced to less than half a wingbeat by increasing flapping amplitude. Subsequent dimensional analysis shows that the time required to unfold passively is of the same order of magnitude as the flapping period. This suggests that centrifugal acceleration can drive passive unfolding within approximately one wingbeat in small and large wings. Finally, we show experimentally that passive unfolding wings can withstand impact with a branch, by first folding and then unfolding passively. This mechanism enables flapping robots to squeeze through clutter without sophisticated control. Passive unfolding also provides a new avenue in morphing wing design that makes future flapping morphing wings possibly more energy efficient and light-weight. Simultaneously these results point to possible inertia driven, and therefore metabolically efficient, control strategies in bats and birds to morph or recover within a beat.

  5. Noise levels from a model turbofan engine with simulated noise control measures applied

    NASA Technical Reports Server (NTRS)

    Hall, David G.; Woodward, Richard P.

    1993-01-01

    A study of estimated full-scale noise levels based on measured levels from the Advanced Ducted Propeller (ADP) sub-scale model is presented. Testing of this model was performed in the NASA Lewis Low Speed Anechoic Wind Tunnel at a simulated takeoff condition of Mach 0.2. Effective Perceived Noise Level (EPNL) estimates for the baseline configuration are documented, and also used as the control case in a study of the potential benefits of two categories of noise control. The effect of active noise control is evaluated by artificially removing various rotor-stator interaction tones. Passive noise control is simulated by applying a notch filter to the wind tunnel data. Cases with both techniques are included to evaluate hybrid active-passive noise control. The results for EPNL values are approximate because the original source data was limited in bandwidth and in sideline angular coverage. The main emphasis is on comparisons between the baseline and configurations with simulated noise control measures.

  6. Investigating the optimal passive and active vibration controls of adjacent buildings based on performance indices using genetic algorithms

    NASA Astrophysics Data System (ADS)

    Hadi, Muhammad N. S.; Uz, Mehmet E.

    2015-02-01

    This study proposes the optimal passive and active damper parameters for achieving the best results in seismic response mitigation of coupled buildings connected to each other by dampers. The optimization to minimize the H2 and H∞ norms in the performance indices is carried out by genetic algorithms (GAs). The final passive and active damper parameters are checked for adjacent buildings connected to each other under El Centro NS 1940 and Kobe NS 1995 excitations. Using real coded GA in H∞ norm, the optimal controller gain is obtained by different combinations of the measurement as the feedback for designing the control force between the buildings. The proposed method is more effective than other metaheuristic methods and more feasible, although the control force increased. The results in the active control system show that the response of adjacent buildings is reduced in an efficient manner.

  7. Whole body vibration improves cognition in healthy young adults.

    PubMed

    Regterschot, G Ruben H; Van Heuvelen, Marieke J G; Zeinstra, Edzard B; Fuermaier, Anselm B M; Tucha, Lara; Koerts, Janneke; Tucha, Oliver; Van Der Zee, Eddy A

    2014-01-01

    This study investigated the acute effects of passive whole body vibration (WBV) on executive functions in healthy young adults. Participants (112 females, 21 males; age: 20.5±2.2 years) underwent six passive WBV sessions (frequency 30 Hz, amplitude approximately 0.5 mm) and six non-vibration control sessions of two minutes each while sitting on a chair mounted on a vibrating platform. A passive WBV session was alternated with a control session. Directly after each session, performance on the Stroop Color-Block Test (CBT), Stroop Color-Word Interference Test (CWIT), Stroop Difference Score (SDS) and Digit Span Backward task (DSBT) was measured. In half of the passive WBV and control sessions the test order was CBT-CWIT-DSBT, and DSBT-CBT-CWIT in the other half. Passive WBV improved CWIT (p = 0.009; effect size r = 0.20) and SDS (p = 0.034; r = 0.16) performance, but only when the CBT and CWIT preceded the DSBT. CBT and DSBT performance did not change. This study shows that two minutes passive WBV has positive acute effects on attention and inhibition in young adults, notwithstanding their high cognitive functioning which could have hampered improvement. This finding indicates the potential of passive WBV as a cognition-enhancing therapy worth further evaluation, especially in persons unable to perform active forms of exercise.

  8. Passive event-related potentials to a single tone in treatment-resistant depression, generalized anxiety disorder, and borderline personality disorder patients.

    PubMed

    Xu, Shaofang; Chai, Hao; Hu, Jing; Xu, You; Chen, Wanzhen; Wang, Wei

    2014-10-01

    Treatment-resistant depression is comorbid with personality or anxiety disorder; how passive attention functions in these disorders remains unknown. A single tone-elicited event-related potential P3 component (passive P3) might help to characterize the passive attention in these disorders. The passive P3 test was applied to 32 patients with treatment-resistant depression, 35 with generalized anxiety disorder, and 21 with borderline personality disorder, as well as to 31 healthy volunteers. The Zung Self-rating Depression and Anxiety Scales were used to measure the respective depression and anxiety levels in these participants. All patients scored significantly higher on depression and anxiety than the healthy participants did. P3 amplitude was significantly reduced in groups with treatment-resistant depression and generalized anxiety disorder but not in the group with borderline personality disorder or healthy controls. Anxiety level was negatively correlated with P3 amplitude in healthy controls rather than in other groups. This study did not discriminate treatment-resistant depression and generalized anxiety disorder regarding the passive P3 but suggested that there was a generalized impairment of passive attention in these disorders.

  9. Biomechanical Comparison of 3 Ankle Braces With and Without Free Rotation in the Sagittal Plane

    PubMed Central

    Alfuth, Martin; Klein, Dieter; Koch, Raphael; Rosenbaum, Dieter

    2014-01-01

    Context: Various designs of braces including hinged and nonhinged models are used to provide external support of the ankle. Hinged ankle braces supposedly allow almost free dorsiflexion and plantar flexion of the foot in the sagittal plane. It is unclear, however, whether this additional degree of freedom affects the stabilizing effect of the brace in the other planes of motion. Objective: To investigate the dynamic and passive stabilizing effects of 3 ankle braces, 2 hinged models that provide free plantar flexion–dorsiflexion in the sagittal plane and 1 ankle brace without a hinge. Design: Crossover study. Setting: University Movement Analysis Laboratory. Patients or Other Participants: Seventeen healthy volunteers (5 women, 12 men; age = 25.4 ± 4.8 years; height = 180.3 ± 6.5 cm; body mass = 75.5 ± 10.4 kg). Intervention(s): We dynamically induced foot inversion on a tilting platform and passively induced foot movements in 6 directions via a custom-built apparatus in 3 brace conditions and a control condition (no brace). Main Outcome Measure(s): Maximum inversion was determined dynamically using an in-shoe electrogoniometer. Passively induced maximal joint angles were measured using a torque and angle sensor. We analyzed differences among the 4 ankle-brace conditions (3 braces, 1 control) for each of the dependent variables with Friedman and post hoc tests (P < .05). Results: Each ankle brace restricted dynamic foot-inversion movements on the tilting platform as compared with the control condition, whereas only the 2 hinged ankle braces differed from each other, with greater movement restriction caused by the Ankle X model. Passive foot inversion was reduced with all ankle braces. Passive plantar flexion was greater in the hinged models as compared with the nonhinged brace. Conclusions: All ankle braces showed stabilizing effects against dynamic and passive foot inversion. Differences between the hinged braces and the nonhinged brace did not appear to be clinically relevant. PMID:25098661

  10. An experimentally based nonlinear viscoelastic model of joint passive moment.

    PubMed

    Esteki, A; Mansour, J M

    1996-04-01

    Previous investigations have not converged on a generally accepted model of the dissipative part of joint passive moment. To provide a basis for developing a model, a series of measurements were performed to characterize the passive moment at the metacarpophalangeal joint of the index finger. Two measurement procedures were used, one in moment relaxation over a range of fixed joint angles and the other at a series of constant joint velocities. Fung's quasi-linear viscoelastic theory motivated the development of the passive moment model. Using this approach, it was not necessary to make restrictive assumptions regarding the viscoelastic behavior of the passive moment. The generality of the formulation allowed specific functions to be chosen based on experimental data rather than finding coefficients which attempted to fit a preselected model of the data. It was shown that a nonlinear viscoelastic model described the passive stiffness. No significant frictional effects were found. Of particular importance was the nonlinear behavior of the dissipative part of the passive moment which was modeled by joint speed raised to a power less than one. This result could explain the differing findings among previous investigations, and may have important implications for control of limb movement.

  11. Supersonic impinging jet noise reduction using a hybrid control technique

    NASA Astrophysics Data System (ADS)

    Wiley, Alex; Kumar, Rajan

    2015-07-01

    Control of the highly resonant flowfield associated with supersonic impinging jet has been experimentally investigated. Measurements were made in the supersonic impinging jet facility at the Florida State University for a Mach 1.5 ideally expanded jet. Measurements included unsteady pressures on a surface plate near the nozzle exit, acoustics in the nearfield and beneath the impingement plane, and velocity field using particle image velocimetry. Both passive control using porous surface and active control with high momentum microjet injection are effective in reducing nearfield noise and flow unsteadiness over a range of geometrical parameters; however, the type of noise reduction achieved by the two techniques is different. The passive control reduces broadband noise whereas microjet injection attenuates high amplitude impinging tones. The hybrid control, a combination of two control methods, reduces both broadband and high amplitude impinging tones and surprisingly its effectiveness is more that the additive effect of the two control techniques. The flow field measurements show that with hybrid control the impinging jet is stabilized and the turbulence quantities such as streamwise turbulence intensity, transverse turbulence intensity and turbulent shear stress are significantly reduced.

  12. A simultaneous deep micromachining and surface passivation method suitable for silicon-based devices

    NASA Astrophysics Data System (ADS)

    Babaei, E.; Gharooni, M.; Mohajerzadeh, S.; Soleimani, E. A.

    2018-07-01

    Three novel methods for simultaneous micromachining and surface passivation of silicon are reported. A thin passivation layer is achieved using continuous and sequential plasma processes based on SF6, H2 and O2 gases. Reducing the recombination by surface passivation is crucial for the realization of high-performance nanosized optoelectronic devices. The passivation of the surface as an important step, is feasible by plasma processing based on hydrogen pulses in proper time-slots or using a mixture of H2 and O2, and SF6 gases. The passivation layer which is formed in situ during the micromachining process obviates a separate passivation step needed in conventional methods. By adjusting the plasma parameters such as power, duration, and flows of gases, the process can be controlled for the best results and acceptable under-etching at the same time. Moreover, the pseudo-oxide layer which is formed during the micromachining processes will also improve the electrical characteristics of the surface, which can be used as an add-on for micro and nanowire applications. To quantify the effect of surface passivation in our method, ellipsometry, lifetime measurements, x-ray photoelectron spectroscopy, current–voltage and capacitance–voltage measurements and solar cell testing have been employed.

  13. Assessment of passive knee stiffness and viscosity in individuals with spinal cord injury using pendulum test

    PubMed Central

    Joghtaei, Mahmoud; Arab, Amir Massoud; Hashemi-Nasl, Hamed; Joghataei, Mohammad Taghi; Tokhi, Mohammad Osman

    2015-01-01

    Objective Stiffness and viscosity represent passive resistances to joint motion related with the structural properties of the joint tissue and of the musculotendinous complex. Both parameters can be affected in patients with spinal cord injury (SCI). The purpose of this study was to measure passive knee stiffness and viscosity in patients with SCI with paraplegia and healthy subjects using Wartenberg pendulum test. Design Non-experimental, cross-sectional, case–control design. Setting An outpatient physical therapy clinic, University of social welfare and Rehabilitation Science, Iran. Patients A sample of convenience sample of 30 subjects participated in the study. Subjects were categorized into two groups: individuals with paraplegic SCI (n = 15, age: 34.60 ± 9.18 years) and 15 able-bodied individuals as control group (n = 15, age: 30.66 ± 11.13 years). Interventions Not applicable. Main measures Passive pendulum test of Wartenberg was used to measure passive viscous-elastic parameters of the knee (stiffness, viscosity) in all subjects. Results Statistical analysis (independent t-test) revealed significant difference in the joint stiffness between healthy subjects and those with paraplegic SCI (P = 0.01). However, no significant difference was found in the viscosity between two groups (P = 0.17). Except for first peak flexion angle, all other displacement kinematic parameters exhibited no statistically significant difference between normal subjects and subjects with SCI. Conclusions Patients with SCI have significantly greater joint stiffness compared to able-bodied subjects. PMID:25437824

  14. Influence of Temperature and Chloride Concentration on Passivation Mechanism and Corrosion of a DSS2209 Welded Joint

    NASA Astrophysics Data System (ADS)

    Hachemi, Hania; Azzaz, Mohamed; Djeghlal, Mohamed Elamine

    2016-10-01

    The passivity behavior of a 2209 duplex stainless steel welded joint was investigated using potentiodynamic polarization, Mott-Schottky analysis and EIS measurements. In order to evaluate the contribution of temperature, chloride concentration and microstructure, a sequence of polarization tests were carried out in aerated NaCl solutions selected according to robust design of a three level-three factors Taguchi L9 orthogonal array. Analysis of signal-to-noise ratio and ANOVA were achieved on all measured data, and the contribution of every control factor was estimated. The results showed that the corrosion resistance of 2209 duplex stainless steel welded joint is related to the evolution of the passive film formed on the surface. It was found that the passive film on the welded zone possessed n- and p-type semiconductor characteristics. With the increase of solution temperature and chlorides concentration, the corrosion resistance of the passive film is more affected in the weldment than in the base metal.

  15. Comparison of the effects of local cryotherapy and passive cross-body stretch on extensibility in subjects with posterior shoulder tightness.

    PubMed

    Park, Kyue-Nam; Kwon, Oh-Yun; Weon, Jong-Hyuck; Choung, Sung-Dae; Kim, Si-Hyun

    2014-01-01

    The objective was to compare the immediate effects of local cryotherapy (LC) and passive cross-body stretch on the extensibility of the posterior shoulder muscle in individuals with posterior shoulder tightness. Eighty-seven healthy subjects with a between-shoulder difference in internal rotation (IR) range of motion (ROM) greater than 10° were randomly divided into three groups: LC group, stretching group, and control group (n = 29 in each group). Subjects in the LC group received LC on infraspinatus and posterior deltoid muscles and subjects in the stretching group performed passive cross-body stretch. Stretch sensation was measured at the end range of passive IR and horizontal adduction (HA) using numerical rating scale, and the pressure pain threshold (PPT) at the infraspinatus and posterior deltoid muscles was measured using pressure algometry. Passive and active ROM of IR and HA of the glenohumeral joint were measured using an inclinometer. All measurements were performed at pre-intervention, post- intervention, and 10-min follow-up. Stretch sensation was significantly decreased and PPT was significantly increased in the LC and stretching groups at post-intervention, and these effects were maintained at 10-min follow-up, compared to the control group. Both the LC group and stretching group had a significantly greater increase in passive and active ROM of IR and HA, compared to the control group at post-intervention and 10-min follow-up. However, there were no significant differences in stretch sensation, PPT, or ROM of IR and HA between the LC group and stretching group. LC can be used to decrease the stretch sensation and increase PPT and ROM of IR and HA as much as a stretching exercise. LC could be an alternative method for increasing the restricted ROM of glenohumeral IR and HA for individuals with posterior shoulder tightness, especially for patients and sports players who have severe stretching discomfort. Key PointsLocal cryotherapy (LC) decreased the uncomfortable stretch sensation, and increased the pressure pain threshold (PPT) of infraspinatus and posterior deltoid muscles in subjects with posterior shoulder tightness.Decreased stretch sensation by LC without passive stretching could improve the passive and active ROM of internal rotation and horizontal adduction in subjects with posterior shoulder tightness, similar to cross-body stretch.LC can be an alternative method to increase extensibility when individuals with posterior shoulder tightness have high stretch sensitivity and low PPT in the infraspinatus and posterior deltoid muscles.

  16. Comparison of the Effects of Local Cryotherapy and Passive Cross-Body Stretch on Extensibility in Subjects with Posterior Shoulder Tightness

    PubMed Central

    Park, Kyue-nam; Kwon, Oh-yun; Weon, Jong-hyuck; Choung, Sung-dae; Kim, Si-hyun

    2014-01-01

    The objective was to compare the immediate effects of local cryotherapy (LC) and passive cross-body stretch on the extensibility of the posterior shoulder muscle in individuals with posterior shoulder tightness. Eighty-seven healthy subjects with a between-shoulder difference in internal rotation (IR) range of motion (ROM) greater than 10° were randomly divided into three groups: LC group, stretching group, and control group (n = 29 in each group). Subjects in the LC group received LC on infraspinatus and posterior deltoid muscles and subjects in the stretching group performed passive cross-body stretch. Stretch sensation was measured at the end range of passive IR and horizontal adduction (HA) using numerical rating scale, and the pressure pain threshold (PPT) at the infraspinatus and posterior deltoid muscles was measured using pressure algometry. Passive and active ROM of IR and HA of the glenohumeral joint were measured using an inclinometer. All measurements were performed at pre-intervention, post- intervention, and 10-min follow-up. Stretch sensation was significantly decreased and PPT was significantly increased in the LC and stretching groups at post-intervention, and these effects were maintained at 10-min follow-up, compared to the control group. Both the LC group and stretching group had a significantly greater increase in passive and active ROM of IR and HA, compared to the control group at post-intervention and 10-min follow-up. However, there were no significant differences in stretch sensation, PPT, or ROM of IR and HA between the LC group and stretching group. LC can be used to decrease the stretch sensation and increase PPT and ROM of IR and HA as much as a stretching exercise. LC could be an alternative method for increasing the restricted ROM of glenohumeral IR and HA for individuals with posterior shoulder tightness, especially for patients and sports players who have severe stretching discomfort. Key Points Local cryotherapy (LC) decreased the uncomfortable stretch sensation, and increased the pressure pain threshold (PPT) of infraspinatus and posterior deltoid muscles in subjects with posterior shoulder tightness. Decreased stretch sensation by LC without passive stretching could improve the passive and active ROM of internal rotation and horizontal adduction in subjects with posterior shoulder tightness, similar to cross-body stretch. LC can be an alternative method to increase extensibility when individuals with posterior shoulder tightness have high stretch sensitivity and low PPT in the infraspinatus and posterior deltoid muscles. PMID:24570610

  17. Measurement of Passive Uptake Rates for Volatile Organic Compounds on Commercial Thermal Desorption Tubes and the Effect of Ozone on Sampling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maddalena, Randy; Parra, Amanda; Russell, Marion

    Diffusive or passive sampling methods using commercially filled axial-sampling thermal desorption tubes are widely used for measuring volatile organic compounds (VOCs) in air. The passive sampling method provides a robust, cost effective way to measure air quality with time-averaged concentrations spanning up to a week or more. Sampling rates for VOCs can be calculated using tube geometry and Fick’s Law for ideal diffusion behavior or measured experimentally. There is evidence that uptake rates deviate from ideal and may not be constant over time. Therefore, experimentally measured sampling rates are preferred. In this project, a calibration chamber with a continuous stirredmore » tank reactor design and constant VOC source was combined with active sampling to generate a controlled dynamic calibration environment for passive samplers. The chamber air was augmented with a continuous source of 45 VOCs ranging from pentane to diethyl phthalate representing a variety of chemical classes and physiochemical properties. Both passive and active samples were collected on commercially filled Tenax TA thermal desorption tubes over an 11-day period and used to calculate passive sampling rates. A second experiment was designed to determine the impact of ozone on passive sampling by using the calibration chamber to passively load five terpenes on a set of Tenax tubes and then exposing the tubes to different ozone environments with and without ozone scrubbers attached to the tube inlet. During the sampling rate experiment, the measured diffusive uptake was constant for up to seven days for most of the VOCs tested but deviated from linearity for some of the more volatile compounds between seven and eleven days. In the ozone experiment, both exposed and unexposed tubes showed a similar decline in terpene mass over time indicating back diffusion when uncapped tubes were transferred to a clean environment but there was no indication of significant loss by ozone reaction.« less

  18. The nonlinearity of passive extraocular muscles

    PubMed Central

    Quaia, Christian; Ying, Howard S.; Optican, Lance M.

    2011-01-01

    Passive extraocular muscles (EOMs), like most biological tissues, are hyper-elastic, i.e., their stiffness increases as they are stretched. It has always been assumed, and in a few occasions argued, that this is their only nonlinearity and that it can be ignored in central gaze. However, using novel measurement techniques in anesthetized paralyzed monkeys, we have recently demonstrated that EOMs are characterized by another prominent nonlinearity: the forces induced by sequences of stretches do not sum. Thus, superposition, a central tenet of linear and quasi-linear models, does not hold in passive EOMs. Here, we outline the implications of this finding, especially in light of the common assumption that it is easier for the brain to control a linear than a nonlinear plant. We argue against this common belief: the specific nonlinearity of passive EOMs may actually make it easier for the brain to control the plant than if muscles were linear. PMID:21950971

  19. On the Control of the Fixed Charge Densities in Al2O3-Based Silicon Surface Passivation Schemes.

    PubMed

    Simon, Daniel K; Jordan, Paul M; Mikolajick, Thomas; Dirnstorfer, Ingo

    2015-12-30

    A controlled field-effect passivation by a well-defined density of fixed charges is crucial for modern solar cell surface passivation schemes. Al2O3 nanolayers grown by atomic layer deposition contain negative fixed charges. Electrical measurements on slant-etched layers reveal that these charges are located within a 1 nm distance to the interface with the Si substrate. When inserting additional interface layers, the fixed charge density can be continuously adjusted from 3.5 × 10(12) cm(-2) (negative polarity) to 0.0 and up to 4.0 × 10(12) cm(-2) (positive polarity). A HfO2 interface layer of one or more monolayers reduces the negative fixed charges in Al2O3 to zero. The role of HfO2 is described as an inert spacer controlling the distance between Al2O3 and the Si substrate. It is suggested that this spacer alters the nonstoichiometric initial Al2O3 growth regime, which is responsible for the charge formation. On the basis of this charge-free HfO2/Al2O3 stack, negative or positive fixed charges can be formed by introducing additional thin Al2O3 or SiO2 layers between the Si substrate and this HfO2/Al2O3 capping layer. All stacks provide very good passivation of the silicon surface. The measured effective carrier lifetimes are between 1 and 30 ms. This charge control in Al2O3 nanolayers allows the construction of zero-fixed-charge passivation layers as well as layers with tailored fixed charge densities for future solar cell concepts and other field-effect based devices.

  20. A passive heat maintenance strategy implemented during a simulated half-time improves lower body power output and repeated sprint ability in professional Rugby Union players.

    PubMed

    Russell, Mark; West, Daniel J; Briggs, Marc A; Bracken, Richard M; Cook, Christian J; Giroud, Thibault; Gill, Nicholas; Kilduff, Liam P

    2015-01-01

    Reduced physical performance has been observed following the half-time period in team sports players, likely due to a decrease in muscle temperature during this period. We examined the effects of a passive heat maintenance strategy employed between successive exercise bouts on core temperature (Tcore) and subsequent exercise performance. Eighteen professional Rugby Union players completed this randomised and counter-balanced study. After a standardised warm-up (WU) and 15 min of rest, players completed a repeated sprint test (RSSA 1) and countermovement jumps (CMJ). Thereafter, in normal training attire (Control) or a survival jacket (Passive), players rested for a further 15 min (simulating a typical half-time) before performing a second RSSA (RSSA 2) and CMJ's. Measurements of Tcore were taken at baseline, post-WU, pre-RSSA 1, post-RSSA 1 and pre-RSSA 2. Peak power output (PPO) and repeated sprint ability was assessed before and after the simulated half-time. Similar Tcore responses were observed between conditions at baseline (Control: 37.06±0.05°C; Passive: 37.03±0.05°C) and for all other Tcore measurements taken before half-time. After the simulated half-time, the decline in Tcore was lower (-0.74±0.08% vs. -1.54±0.06%, p<0.001) and PPO was higher (5610±105 W vs. 5440±105 W, p<0.001) in the Passive versus Control condition. The decline in PPO over half-time was related to the decline in Tcore (r = 0.632, p = 0.005). In RSSA 2, best, mean and total sprint times were 1.39±0.17% (p<0.001), 0.55±0.06% (p<0.001) and 0.55±0.06% (p<0.001) faster for Passive versus Control. Passive heat maintenance reduced declines in Tcore that were observed during a simulated half-time period and improved subsequent PPO and repeated sprint ability in professional Rugby Union players.

  1. Knee joint laxity and passive stiffness in meniscectomized patients compared with healthy controls.

    PubMed

    Thorlund, Jonas B; Creaby, Mark W; Wrigley, Tim V; Metcalf, Ben R; Bennell, Kim L

    2014-10-01

    Passive mechanical behavior of the knee in the frontal plane, measured as angular laxity and mechanical stiffness, may play an important role in the pathogenesis of knee osteoarthritis (OA). Little is known about knee laxity and stiffness prior to knee OA onset. We investigated knee joint angular laxity and passive stiffness in meniscectomized patients at high risk of knee OA compared with healthy controls. Sixty patients meniscectomized for a medial meniscal tear (52 men, 41.4 ± 5.5 years, 175.3 ± 7.9 cm, 83.6 ± 12.8 kg, mean ± SD) and 21 healthy controls (18 men, 42.0 ± 6.7 years, 176.8 ± 5.7 cm, 77.8 ± 13.4 kg) had their knee joint angular laxity and passive stiffness assessed twice ~2.3 years apart. Linear regression models including age, sex, height and body mass as covariates in the adjusted model were used to assess differences between groups. Greater knee joint varus (-10.1 vs. -7.3°, p<0.001), valgus (7.1 vs. 5.6°, p=0.001) and total (17.2 vs. 12.9°, p<0.001) angular laxity together with reduced midrange passive stiffness (1.71 vs. 2.36 Nm/°, p<0.001) were observed in patients vs. healthy controls. No differences were observed in change in stiffness over time between patients and controls, however a tendency towards increased laxity in patients was seen. Meniscectomized patients showed increased knee joint angular laxity and reduced passive stiffness ~3 months post surgery compared with controls. In addition, the results indicated that knee joint laxity may increase over time in meniscectomized patients. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. [Population characteristics and impact on heart rate variability, heart rate and blood pressure of passive smoking].

    PubMed

    Zhao, Jing; He, Fei; Hu, Da-yi; Ding, Rong-jing; Yu, Xiao-jun; Wang, Long; Zhang, Ping; Li, Xue-bin; Guo, Ji-hong; Liu, Wen-ling; Li, Cui-lan; Li, Lei; Gao, Chuan-yu; Zhao, Luo-sha; Chu, Ying-jie; Huang, Zhen-wen; Wei, Jing-han; Hua, Shao-hua; Liu, Rui-yun; Zhuang, Xiao-feng

    2013-05-01

    To investigate the basic characteristics of passive smoking population, and the impact of passive smoking on heart rate variability, heart rate and blood pressure. Eighty-six passive smokers [mean age: (52.4 ± 7.6) years] were recruited from patients and their relatives who visited cardiovascular outpatient department and excluded structural heart disease between June 2010 and June 2012, 80 normal subjects who were not exposed to smoking served as controls. Questionnaire survey, 24 hours ambulatory electrocardiogram examination and blood pressure measurement were performed in all recruited subjects. (1) Non-marriage rate [18.60% (16/86) vs. 3.75% (3/80), P < 0.01] was significantly higher while education level were significantly lower in passive smoking group than in control group. Passive smokers were more likely service industry workers [29.07% (25/86) vs. 15.00% (12/80), P < 0.05] and had longer daily working time [(7.56 ± 1.24) h vs. (6.02 ± 0.96) h, P < 0.01], and were less likely to be professional technology industry employers [20.93% (18/86) vs. 36.25% (29/80), P < 0.05] and managers [13.95% (12/86) vs. 38.75% (31/80), P < 0.01] compared to controls. The main place of passive smoking was workplace (67.44%, 58/86), entertainment venues (63.95%,55/86), restaurants (48.84%, 42/86). (2) Standard of the normal sinus RR intervals (SDNN), the normal consecutive sinus RR interval difference between the root-mean-square (rMSSD) and adjacent the difference between the RR interval>50 ms the number of share the percentage (PNN50) were significantly lower in passive smoking group than in the control group (all P < 0.05). Every 5 min average of the standard deviation of sinus RR cycle (SDNN index) and 24 h every 5 min sinus RR interval mean standard deviation (SDANN) were similar between the 2 groups (all P > 0.05). Ultra-low-frequency power (VLF), low frequency power (LF), high frequency power (HF) and LF/HF were significantly lower in passive smoking group than in the control group (all P < 0.01). (3) Heart rate and diastolic blood pressure were significantly higher in passive smoking group than in control group (all P < 0.05) while systolic blood pressure was similar between the 2 groups (P > 0.05). Marriage status, education level, profession and daily working time are independent determinants for passive smoking. Passive smoking mainly occurred in the workplace, entertainment venues and restaurants. Passive smoking is linked with reduced heart rate variability, increased 24 h average heart rate and diastolic blood pressure.

  3. Increased oxidative stress in infants exposed to passive smoking.

    PubMed

    Aycicek, Ali; Erel, Ozcan; Kocyigit, Abdurrahim

    2005-12-01

    The purpose of this study was to assess the effect of passive cigarette smoking on the oxidative and anti-oxidative status of plasma in infants. Eighty-four infants aged 6-28 weeks were divided into two groups: the study group included infants who had been exposed to passive smoking via at least five cigarettes per day for at least the past 6 weeks at home, while the control group included infants who had never been exposed to passive smoking. The antioxidative status of plasma was assessed by the measurement of individual antioxidant components: vitamin C, albumin, bilirubin, uric acid, thiol contents and total antioxidant capacity (TAC 1 and TAC 2). Oxidative status was assessed by the determination of total peroxide levels and the oxidative stress index (OSI 1 and OSI 2). Plasma vitamin C, thiol concentration and TAC 1 and TAC 2 levels were significantly lower, whereas plasma total peroxide levels and OSI 1 and OSI 2 were significantly higher, in passive smoking infants than in the controls (P<0.01). We conclude that passive smoking has a negative impact on numerous parts of the antioxidant defence system in infants, and exposes them to potent oxidative stress.

  4. Dynamic analysis to evaluate viscoelastic passive damping augmentation for the Space Shuttle Remote Manipulator System

    NASA Technical Reports Server (NTRS)

    Alberts, Thomas E.; Xia, Houchun; Chen, Yung

    1992-01-01

    The effectiveness of constrained viscoelastic layer damping treatment designs is evaluated separately as passive control measures for low frequency joint dominated modes and higher frequency boom flexure dominated modes using a NASTRAN finite element analysis. Passive damping augmentation is proposed which is based on a constrained viscoelastic layer damping treatment applied to the surface of the manipulators's flexible booms. It is pointed out that even the joint compliance dominated modes can be damped to some degree through appropriate design of the treatment.

  5. Pupil measures of alertness and mental load

    NASA Technical Reports Server (NTRS)

    Backs, Richard W.; Walrath, Larry C.

    1988-01-01

    A study of eight adults given active and passive search tasks showed that evoked pupillary response was sensitive to information processing demands. In particular, large pupillary diameter was observed in the active search condition where subjects were actively processing information relevant to task performance, as opposed to the passive search (control) condition where subjects passively viewed the displays. However, subjects may have simply been more aroused in the active search task. Of greater importance was that larger pupillary diameter, corresponding to longer search time, was observed for noncoded than for color-coded displays in active search. In the control condition, pupil diameter was larger with the color displays. The data indicate potential usefulness of pupillary responses in evaluating the information processing requirements of visual displays.

  6. Maternal active or passive smoking causes oxidative stress in placental tissue.

    PubMed

    Aycicek, Ali; Varma, Mustafa; Ahmet, Koc; Abdurrahim, Kocyigit; Erel, Ozcan

    2011-05-01

    The aim of this study was to assess the influence of active and passive maternal smoking on placenta total oxidant/antioxidant status in term infants. The levels of cord blood total antioxidant capacity (TAC), total oxidant status (TOS), and oxidative stress index (OSI) were measured in samples of fetal placental tissue, cord blood, and the maternal peripheral blood serum and from 19 mothers who were active smokers, 19 who were passive smokers, and 22 who were nonsmokers (not exposed to active or passive smoking). The pregnancies were between 37 and 40 weeks' gestation, were uncomplicated, and the infants were delivered vaginally. Birth weight and head circumference in the active smokers were significantly (P < 0.001) lower than those in the controls. Placenta, cord blood, and the maternal peripheral TAC levels were significantly lower in the active smokers compared with the controls (P < 0.001), while TOS and OSI levels were significantly higher in the active and passive smokers than in the controls (P < 0.001). A positive significant correlation was found between active maternal smoking and placenta TOS and OSI levels (P < 0.016), and a significant negative correlation was found between number of cigarettes exposed to and birthweight and head circumference (P < 0.05). In conclusion, active or passive maternal smoking is associated with important alterations in oxidant and antioxidant balance in fetal placental tissue and causes potent oxidative stress.

  7. Assessment of passive knee stiffness and viscosity in individuals with spinal cord injury using pendulum test.

    PubMed

    Joghtaei, Mahmoud; Arab, Amir Massoud; Hashemi-Nasl, Hamed; Joghataei, Mohammad Taghi; Tokhi, Mohammad Osman

    2015-03-01

    Stiffness and viscosity represent passive resistances to joint motion related with the structural properties of the joint tissue and of the musculotendinous complex. Both parameters can be affected in patients with spinal cord injury (SCI). The purpose of this study was to measure passive knee stiffness and viscosity in patients with SCI with paraplegia and healthy subjects using Wartenberg pendulum test. Non-experimental, cross-sectional, case-control design. An outpatient physical therapy clinic, University of social welfare and Rehabilitation Science, Iran. A sample of convenience sample of 30 subjects participated in the study. Subjects were categorized into two groups: individuals with paraplegic SCI (n = 15, age: 34.60 ± 9.18 years) and 15 able-bodied individuals as control group (n = 15, age: 30.66 ± 11.13 years). Not applicable. Passive pendulum test of Wartenberg was used to measure passive viscous-elastic parameters of the knee (stiffness, viscosity) in all subjects. Statistical analysis (independent t-test) revealed significant difference in the joint stiffness between healthy subjects and those with paraplegic SCI (P = 0.01). However, no significant difference was found in the viscosity between two groups (P = 0.17). Except for first peak flexion angle, all other displacement kinematic parameters exhibited no statistically significant difference between normal subjects and subjects with SCI. Patients with SCI have significantly greater joint stiffness compared to able-bodied subjects.

  8. Task-dependent V1 responses in human retinitis pigmentosa.

    PubMed

    Masuda, Yoichiro; Horiguchi, Hiroshi; Dumoulin, Serge O; Furuta, Ayumu; Miyauchi, Satoru; Nakadomari, Satoshi; Wandell, Brian A

    2010-10-01

    During measurement with functional MRI (fMRI) during passive viewing, subjects with macular degeneration (MD) have a large unresponsive lesion projection zone (LPZ) in V1. fMRI responses can be evoked from the LPZ when subjects engage in a stimulus-related task. The authors report fMRI measurements on a different class of subjects, those with retinitis pigmentosa (RP), who have intact foveal vision but peripheral visual field loss. The authors measured three RP subjects and two control subjects. fMRI was performed while the subjects viewed drifting contrast pattern stimuli. The subjects passively viewed the stimuli or performed a stimulus-related task. During passive viewing, the BOLD response in the posterior calcarine cortex of all RP subjects was in phase with the stimulus. A bordering, anterior LPZ could be identified by responses that were in opposite phase to the stimulus. When the RP subjects made stimulus-related judgments, however, the LPZ responses changed: the responses modulated in phase with the stimulus and task. In control subjects, the responses in a simulated V1 LPZ were unchanged between the passive and the stimulus-related judgment conditions. Task-dependent LPZ responses are present in RP subjects, similar to responses measured in MD subjects. The results are consistent with the hypothesis that deleting the retinal input to the LPZ unmasks preexisting extrastriate feedback signals that are present across V1. The authors discuss the implications of this hypothesis for visual therapy designed to replace the missing V1 LPZ inputs and to restore vision.

  9. Local Probing Spinel and Perovskite Complex Magnetic Systems

    NASA Astrophysics Data System (ADS)

    Oliveira, Goncalo Nuno de Pinho

    Noise is defined as unwanted sound, when perceived in excess can cause many harmful effects such as annoyance, interference with speech, and hearing loss, hence there is a need to control noise in practical situations. Noise can be controlled actively and/or passively, here we discuss the passive noise control techniques. Passive noise control involves using energy dissipating or reflecting materials such as absorbers or barriers respectively. Damping and isolating materials are also used in eliminating structure-borne noise. These materials exhibit properties such as reflection, absorption and transmission loss when incidence is by a sound source. Thus, there is a need to characterize the acoustical properties of these materials for practical use. The theoretical background of the random incident sound absorption with reverberation room and normal incident sound absorption using impedance tube are well documented. The Transfer Matrix method for measuring transmission loss and absorption coefficient using impedance tube is very attractive since it is rather inexpensive and fast. In this research, a low-cost Impedance Tube is constructed using transfer function method to measure both absorption and transmissibility of materials. Equipment and measurement instruments available in the laboratory were used in the construction of the tube, adhering to cost-effectiveness. Care has been taken for precise construction of tube to ensure better measurement results. Further various samples varying from hard non-porous to soft porous materials were tested for absorption and sound transmission loss. Absorption values were also compared with reverberation room method with the available samples further ensuring the reliability of the newly constructed tube for future measurements.

  10. Effect of passive concentration as instructional set for training enhancement of EEG alpha.

    PubMed

    Knox, S S

    1980-12-01

    The technique of passive concentration, employed by autogenic training and Transcendental Meditation for achieving relaxation, was tested here as a technique for enhancing EEG alpha. Of 30 subjects displaying between 15% and 74% alpha in their resting EEGs recruited, 10 had to be eliminated. The remaining 20 constituted two groups. One was instructed only to attempt to maintain a tone indicating alpha but given no information about technique (control group). The other was given additional instructions in passive concentration (experimental group). Both were given four 5-min. trials a day for 4 consecutive days. Heart rate and skin conductance were measured to monitor autonomic arousal. The group receiving instructions in passive concentration had significantly less alpha than the control group, which did not increase amount of alpha above baseline. The reduction of alpha in the experimental group was interpreted as resulting from beginning long training periods (20 min. per day), a practice advocated by Transcendental Meditation but discouraged by autogenic training. It was concluded that the relevance of passive concentration for alpha enhancement is doubtful.

  11. Effects of high-intensity pulse irradiation with linear polarized near-infrared rays and stretching on muscle tone in patients with cerebrovascular disease: a randomized controlled trial.

    PubMed

    Takeuchi, Nobuyuki; Takezako, Nobuhiro; Shimonishi, Yuko; Usuda, Shigeru

    2017-08-01

    [Purpose] The purpose of this study was to clarify the influence of high-intensity pulse irradiation with linear polarized near-infrared rays (HI-LPNR) and stretching on hypertonia in cerebrovascular disease patients. [Subjects and Methods] The subjects were 40 cerebrovascular disease patients with hypertonia of the ankle joint plantar flexor muscle. The subjects were randomly allocated to groups undergoing treatment with HI-LPNR irradiation (HI-LPNR group), stretching (stretching group), HI-LPNR irradiation followed by stretching (combination group), and control group (10 subjects each). In all groups, the passive range of motion of ankle dorsiflexion and passive resistive joint torque of ankle dorsiflexion were measured before and after the specified intervention. [Results] The changes in passive range of motion, significant increase in the stretching and combination groups compared with that in the control group. The changes in passive resistive joint torque, significant decrease in HI-LPNR, stretching, and combination groups compared with that in the control group. [Conclusion] HI-LPNR irradiation and stretching has effect of decrease muscle tone. However, combination of HI-LPNR irradiation and stretching has no multiplier effect.

  12. Stiffness and Damping in Postural Control Increase with Age

    PubMed Central

    Cenciarini, Massimo; Loughlin, Patrick J.; Sparto, Patrick J.; Redfern, Mark S.

    2011-01-01

    Upright balance is believed to be maintained through active and passive mechanisms, both of which have been shown to be impacted by aging. A compensatory balance response often observed in older adults is increased co-contraction, which is generally assumed to enhance stability by increasing joint stiffness. We investigated the effect of aging on standing balance by fitting body sway data to a previously-developed postural control model that includes active and passive stiffness and damping parameters. Ten young (24 ± 3 y) and seven older (75 ± 5 y) adults were exposed during eyes-closed stance to perturbations consisting of lateral pseudorandom floor tilts. A least-squares fit of the measured body sway data to the postural control model found significantly larger active stiffness and damping model parameters in the older adults. These differences remained significant even after normalizing to account for different body sizes between the young and older adult groups. An age effect was also found for the normalized passive stiffness, but not for the normalized passive damping parameter. This concurrent increase in active stiffness and damping was shown to be more stabilizing than an increase in stiffness alone, as assessed by oscillations in the postural control model impulse response. PMID:19770083

  13. Effects of robot-guided passive stretching and active movement training of ankle and mobility impairments in stroke.

    PubMed

    Waldman, Genna; Yang, Chung-Yong; Ren, Yupeng; Liu, Lin; Guo, Xin; Harvey, Richard L; Roth, Elliot J; Zhang, Li-Qun

    2013-01-01

    To investigate the effects of controlled passive stretching and active movement training using a portable rehabilitation robot on stroke survivors with ankle and mobility impairment. Twenty-four patients at least 3 months post stroke were assigned to receive 6 week training using the portable robot in a research laboratory (robot group) or an instructed exercise program at home (control group). All patients underwent clinical and biomechanical evaluations in the laboratory at pre-evaluation, post-evaluation, and 6-week follow-up. Subjects in the robot group improved significantly more than that in the control group in reduction in spasticity measured by modified Ashworth scale, mobility by Stroke Rehabilitation Assessment of Movement (STREAM), the balance by Berg balance score, dorsiflexion passive range of motion, dorsiflexion strength, and load bearing on the affected limb during gait after 6-week training. Both groups improved in the STREAM, dorsiflexion active range of motion and dorsiflexor strength after the training, which were retained in the follow-up evaluation. Robot-assisted passive stretching and active movement training is effective in improving motor function and mobility post stroke.

  14. A GNC Perspective of the Launch and Commissioning of NASA's SMAP (Soil Moisture Active Passive) Spacecraft

    NASA Technical Reports Server (NTRS)

    Brown, Todd S.

    2016-01-01

    The NASA Soil Moisture Active Passive (SMAP) spacecraft was designed to use radar and radiometer measurements to produce global soil moisture measurements every 2-3 days. The SMAP spacecraft is a complicated dual-spinning design with a large 6 meter deployable mesh reflector mounted on a platform that spins at 14.6 rpm while the Guidance Navigation and Control algorithms maintain precise nadir pointing for the de-spun portion of the spacecraft. After launching in early 2015, the Guidance Navigation and Control software and hardware aboard the SMAP spacecraft underwent an intensive spacecraft checkout and commissioning period. This paper describes the activities performed by the Guidance Navigation and Control team to confirm the health and phasing of subsystem hardware and the functionality of the guidance and control modes and algorithms. The operations tasks performed, as well as anomalies that were encountered during the commissioning, are explained and results are summarized.

  15. Nitric oxide and passive limb movement: a new approach to assess vascular function

    PubMed Central

    Trinity, Joel D; Groot, H Jonathan; Layec, Gwenael; Rossman, Matthew J; Ives, Stephen J; Runnels, Sean; Gmelch, Ben; Bledsoe, Amber; Richardson, Russell S

    2012-01-01

    Passive limb movement elicits a robust increase in limb blood flow (LBF) and limb vascular conductance (LVC), but the peripheral vascular mechanisms associated with this increase in LBF and LVC are unknown. This study sought to determine the contribution of nitric oxide (NO) to movement-induced LBF and LVC and document the potential for passive-limb movement to assess NO-mediated vasodilatation and therefore NO bioavailability. Six subjects underwent passive knee extension with and without nitric oxide synthase (NOS) inhibition via intra-arterial infusion of NG-monomethyl-l-arginine (l-NMMA). LBF was determined second-by-second by Doppler ultrasound, and central haemodynamics were measured by finger photoplethysmography. Although l-NMMA did not alter the immediate increase (initial ∼9 s) in LBF and LVC, NOS blockade attenuated the peak increase in LBF (control: 653 ± 81; l-NMMA: 399 ± 112 ml−1 min−1, P= 0.03) and LVC (control: 7.5 ± 0.8; l-NMMA: 4.1 ± 1.1 ml min−1 mmHg−1, P= 0.02) and dramatically reduced the overall vasodilatory and hyperaemic response (area under the curve) by nearly 80% (LBF: control: 270 ± 51; l-NMMA: 75 ± 32 ml, P= 0.001; LVC: control: 2.9 ± 0.5; l-NMMA: 0.8 ± 0.3 ml mmHg−1, P < 0.001). Passive movement in control and l-NMMA trials evoked similar increases in heart rate, stroke volume, cardiac output and a reduction in mean arterial pressure. As movement-induced increases in LBF and LVC are predominantly NO dependent, passive limb movement appears to have significant promise as a new approach to assess NO-mediated vascular function, an important predictor of cardiovascular disease risk. PMID:22310310

  16. Design And Construction of an Impedance Tube for Measuring Sound Absorptivity and Transmissibility of Materials Using Transfer Function Method

    NASA Astrophysics Data System (ADS)

    Gowda, Haarish Kapaninaikappa

    Noise is defined as unwanted sound, when perceived in excess can cause many harmful effects such as annoyance, interference with speech, and hearing loss, hence there is a need to control noise in practical situations. Noise can be controlled actively and/or passively, here we discuss the passive noise control techniques. Passive noise control involves using energy dissipating or reflecting materials such as absorbers or barriers respectively. Damping and isolating materials are also used in eliminating structure-borne noise. These materials exhibit properties such as reflection, absorption and transmission loss when incidence is by a sound source. Thus, there is a need to characterize the acoustical properties of these materials for practical use. The theoretical background of the random incident sound absorption with reverberation room and normal incident sound absorption using impedance tube are well documented. The Transfer Matrix method for measuring transmission loss and absorption coefficient using impedance tube is very attractive since it is rather inexpensive and fast. In this research, a low-cost Impedance Tube is constructed using transfer function method to measure both absorption and transmissibility of materials. Equipment and measurement instruments available in the laboratory were used in the construction of the tube, adhering to cost-effectiveness. Care has been taken for precise construction of tube to ensure better measurement results. Further various samples varying from hard non-porous to soft porous materials were tested for absorption and sound transmission loss. Absorption values were also compared with reverberation room method with the available samples further ensuring the reliability of the newly constructed tube for future measurements.

  17. A Comparison of Active and Passive Methods for Control of Hypersonic Boundary Layers on Airbreathing Configurations

    NASA Technical Reports Server (NTRS)

    Berry, Scott A.; Nowak, Robert J.

    2003-01-01

    Active and passive methods for control of hypersonic boundary layers have been experimentally examined in NASA Langley Research Center wind tunnels on a Hyper-X model. Several configurations for forcing transition using passive discrete roughness elements and active mass addition, or blowing, methods were compared in two hypersonic facilities, the 20-Inch Mach 6 Air and the 31-Inch Mach 10 Air tunnels. Heat transfer distributions, obtained via phosphor thermography, shock system details, and surface streamline patterns were measured on a 0.333-scale model of the Hyper-X forebody. The comparisons between the active and passive methods for boundary layer control were conducted at test conditions that nearly match the nominal Mach 7 flight trajectory of an angle-of-attack of 2-deg and length Reynolds number of 5.6 million. For the passive roughness examination, the primary parametric variation was a range of trip heights within the calculated boundary layer thickness for several trip concepts. The prior passive roughness study resulted in a swept ramp configuration being selected for the Mach 7 flight vehicle that was scaled to be roughly 0.6 of the calculated boundary layer thickness. For the active jet blowing study, the blowing manifold pressure was systematically varied for each configuration, while monitoring the mass flow, to determine the jet penetration height with schlieren and transition movement with the phosphor system for comparison to the passive results. All the blowing concepts tested were adequate for providing transition onset near the trip location with manifold stagnation pressures on the order of 40 times the model static pressure or higher.

  18. Thermal control materials on EOIM-3

    NASA Technical Reports Server (NTRS)

    Finckenor, Miria M.; Linton, Roger C.; Kamenetzky, Rachel R.; Vaughn, Jason A.

    1995-01-01

    Thermal control paints, anodized aluminum, and beta cloth samples were flown on STS-46 as part of the Evaluation of Oxygen Interaction with Materials Experiment (EOIM-3). The thermal control paints flown on EOIM-3 include ceramic and polyurethane-based paints. Passively exposed samples are compared to actively heated samples and controlled exposure samples. Optical property measurements of absorptivity, emissivity, and spectrofluorescence are presented for each paint. Several variations of anodized aluminum, including chromic acid anodize, sulfuric acid anodize, and boric/sulfuric acid anodize were flown on the actively heated trays and the passive exposure trays. The post-flight optical properties are within tolerances for these materials. Also flown were two samples of yellow anodized aluminum. The yellow anodized aluminum samples darkened noticeably. Samples of aluminized and unaluminized beta cloth, a fiberglass woven mat impregnated with TFE Teflon, were flown with passive exposure to the space environment. Data from this part of the experiment is correlated to observations from LDEF and erosion of the Teflon thin film samples also flown on EOIM-3 and LDEF.

  19. Active and Passive Fatigue in Simulated Driving: Discriminating Styles of Workload Regulation and Their Safety Impacts

    PubMed Central

    Saxby, Dyani J.; Matthews, Gerald; Warm, Joel S.; Hitchcock, Edward M.; Neubauer, Catherine

    2015-01-01

    Despite the known dangers of driver fatigue, it is a difficult construct to study empirically. Different forms of task-induced fatigue may differ in their effects on driver performance and safety. Desmond and Hancock (2001) defined active and passive fatigue states that reflect different styles of workload regulation. In 2 driving simulator studies we investigated the multidimensional subjective states and safety outcomes associated with active and passive fatigue. Wind gusts were used to induce active fatigue, and full vehicle automation to induce passive fatigue. Drive duration was independently manipulated to track the development of fatigue states over time. Participants were undergraduate students. Study 1 (N = 108) focused on subjective response and associated cognitive stress processes, while Study 2 (N = 168) tested fatigue effects on vehicle control and alertness. In both studies the 2 fatigue manipulations produced different patterns of subjective response reflecting different styles of workload regulation, appraisal, and coping. Active fatigue was associated with distress, overload, and heightened coping efforts, whereas passive fatigue corresponded to large-magnitude declines in task engagement, cognitive underload, and reduced challenge appraisal. Study 2 showed that only passive fatigue reduced alertness, operationalized as speed of braking and steering responses to an emergency event. Passive fatigue also increased crash probability, but did not affect a measure of vehicle control. Findings support theories that see fatigue as an outcome of strategies for managing workload. The distinction between active and passive fatigue is important for assessment of fatigue and for evaluating automated driving systems which may induce dangerous levels of passive fatigue. PMID:24041288

  20. Quantitative passive soil vapor sampling for VOCs--Part 4: Flow-through cell.

    PubMed

    McAlary, Todd; Groenevelt, Hester; Seethapathy, Suresh; Sacco, Paolo; Crump, Derrick; Tuday, Michael; Schumacher, Brian; Hayes, Heidi; Johnson, Paul; Parker, Louise; Górecki, Tadeusz

    2014-05-01

    This paper presents a controlled experiment comparing several quantitative passive samplers for monitoring concentrations of volatile organic compound (VOC) vapors in soil gas using a flow-through cell. This application is simpler than conventional active sampling using adsorptive tubes because the flow rate does not need to be precisely measured and controlled, which is advantageous because the permeability of subsurface materials affects the flow rate and the permeability of geologic materials is highly variable. Using passive samplers in a flow-through cell, the flow rate may not need to be known exactly, as long as it is sufficient to purge the cell in a reasonable time and minimize any negative bias attributable to the starvation effect. An experiment was performed in a 500 mL flow-through cell using a two-factor, one-half fraction fractional factorial test design with flow rates of 80, 670 and 930 mL min(-1) and sample durations of 10, 15 and 20 minutes for each of five different passive samplers (passive Automatic Thermal Desorption Tube, Radiello®, SKC Ultra, Waterloo Membrane Sampler™ and 3M™ OVM 3500). A Summa canister was collected coincident with each passive sampler and analyzed by EPA Method TO-15 to provide a baseline for comparison of the passive sampler concentrations. The passive sampler concentrations were within a factor of 2 of the Summa canister concentrations in 32 of 35 cases. Passive samples collected at the low flow rate and short duration showed low concentrations, which is likely attributable to insufficient purging of the cell after sampler placement.

  1. Optical Pointing Sensor

    NASA Technical Reports Server (NTRS)

    Shields, Joel F.; Metz, Brandon C.

    2010-01-01

    The optical pointing sensor provides a means of directly measuring the relative positions of JPL s Formation Control Testbed (FCT) vehicles without communication. This innovation is a steerable infrared (IR) rangefinder that gives measurements in terms of range and bearing to a passive retroreflector.

  2. Novel Concrete Temperature Monitoring Method Based on an Embedded Passive RFID Sensor Tag.

    PubMed

    Liu, Yongsheng; Deng, Fangming; He, Yigang; Li, Bing; Liang, Zhen; Zhou, Shuangxi

    2017-06-22

    This paper firstly introduces the importance of temperature control in concrete measurement, then a passive radio frequency identification (RFID) sensor tag embedded for concrete temperature monitoring is presented. In order to reduce the influences of concrete electromagnetic parameters during the drying process, a T-type antenna is proposed to measure the concrete temperature at the required depth. The proposed RFID sensor tag is based on the EPC generation-2 ultra-high frequency (UHF) communication protocol and operates in passive mode. The temperature sensor can convert the sensor signals to corresponding digital signals without an external reference clock due to the adoption of phase-locked loop (PLL)-based architecture. Laboratory experimentation and on-site testing demonstrate that our sensor tag embedded in concrete can provide reliable communication performance in passive mode. The maximum communicating distance between reader and tag is 7 m at the operating frequency of 915 MHz and the tested results show high consistency with the results tested by a thermocouple.

  3. Novel Concrete Temperature Monitoring Method Based on an Embedded Passive RFID Sensor Tag

    PubMed Central

    Liu, Yongsheng; Deng, Fangming; He, Yigang; Li, Bing; Liang, Zhen; Zhou, Shuangxi

    2017-01-01

    This paper firstly introduces the importance of temperature control in concrete measurement, then a passive radio frequency identification (RFID) sensor tag embedded for concrete temperature monitoring is presented. In order to reduce the influences of concrete electromagnetic parameters during the drying process, a T-type antenna is proposed to measure the concrete temperature at the required depth. The proposed RFID sensor tag is based on the EPC generation-2 ultra-high frequency (UHF) communication protocol and operates in passive mode. The temperature sensor can convert the sensor signals to corresponding digital signals without an external reference clock due to the adoption of phase-locked loop (PLL)-based architecture. Laboratory experimentation and on-site testing demonstrate that our sensor tag embedded in concrete can provide reliable communication performance in passive mode. The maximum communicating distance between reader and tag is 7 m at the operating frequency of 915 MHz and the tested results show high consistency with the results tested by a thermocouple. PMID:28640188

  4. [CLINICAL STUDIES ON EFFECT OF ARTHROSCOPIC INTERCONDYLAR FOSSA ANGIOPLASTY ON ABILITY OF NEUROMUSCULAR CONTROL IN ELDERLY PATIENTS WITH KNEE OSTEOARTHRITIS].

    PubMed

    Huang, Jingmin; Wang, Haijiao; Wu, Jiang; Li, Dongchao; Li, Yuhong

    2015-08-01

    To study the effect of arthroscopic intercondylar fossa angioplasty on the ability of neuromuscular control of the knee joint in elderly patients with knee osteoarthritis (KOA). Between June 2012 and March 2013, 20 elderly patients with KOA and in accordance with inclusion and exclusion criteria underwent arthroscopic intercondylar fossa angioplasty (operation group), and 20 healthy elderly people served as control group. There was no significant difference in age, height, weight, and body mass index between 2 groups (P > 0.05). The proprioception capability (using passive regeneration test at measurement angles of 15, 30, and 60°) and quadriceps mobilization [including maximum voluntary contraction (MVC), central activation ratio (CAR), and activation deficit (AD)] were measured to avaluate the neuromuscular control of the knee; the Lysholm score was used to evaluate knee function. The above indexes were measured to assess the knee neuromuscular control and recovery of joint function in patients of operation group at 3, 6, and 9 months after operation. Compared with the control group, MVC, CAR, and Lysholm scores were significantly decreased, and the AD and passive knee angle difference were significantly increased in operation group (P < 0.05) before operation. With the time after operation, the Lysholm score, CAR, and MVC increased gradually, and the AD and the passive knee angle difference decreased gradually. There was no significant difference in the indexes between 2 groups at 9 months after operation (P > 0.05). Arthroscopic intercondylar fossa angioplasty can relieve ACL pressure, abrasion, and impact, which will recover the ability of neuromuscular control, increase proprioception and quadriceps mobilization capacity, and improve the joint function.

  5. Passive Baited Sequential Fly Trap

    USDA-ARS?s Scientific Manuscript database

    Sampling fly populations associated with human populations is needed to understand diel behavior and to monitor population densities before and after control operations. Population control measures are dependent on the results of monitoring efforts as they may provide insight into the fly behavior ...

  6. Passivation mechanism of thermal atomic layer-deposited Al2O3 films on silicon at different annealing temperatures.

    PubMed

    Zhao, Yan; Zhou, Chunlan; Zhang, Xiang; Zhang, Peng; Dou, Yanan; Wang, Wenjing; Cao, Xingzhong; Wang, Baoyi; Tang, Yehua; Zhou, Su

    2013-03-02

    Thermal atomic layer-deposited (ALD) aluminum oxide (Al2O3) acquires high negative fixed charge density (Qf) and sufficiently low interface trap density after annealing, which enables excellent surface passivation for crystalline silicon. Qf can be controlled by varying the annealing temperatures. In this study, the effect of the annealing temperature of thermal ALD Al2O3 films on p-type Czochralski silicon wafers was investigated. Corona charging measurements revealed that the Qf obtained at 300°C did not significantly affect passivation. The interface-trapping density markedly increased at high annealing temperature (>600°C) and degraded the surface passivation even at a high Qf. Negatively charged or neutral vacancies were found in the samples annealed at 300°C, 500°C, and 750°C using positron annihilation techniques. The Al defect density in the bulk film and the vacancy density near the SiOx/Si interface region decreased with increased temperature. Measurement results of Qf proved that the Al vacancy of the bulk film may not be related to Qf. The defect density in the SiOx region affected the chemical passivation, but other factors may dominantly influence chemical passivation at 750°C.

  7. Passivation mechanism of thermal atomic layer-deposited Al2O3 films on silicon at different annealing temperatures

    PubMed Central

    2013-01-01

    Thermal atomic layer-deposited (ALD) aluminum oxide (Al2O3) acquires high negative fixed charge density (Qf) and sufficiently low interface trap density after annealing, which enables excellent surface passivation for crystalline silicon. Qf can be controlled by varying the annealing temperatures. In this study, the effect of the annealing temperature of thermal ALD Al2O3 films on p-type Czochralski silicon wafers was investigated. Corona charging measurements revealed that the Qf obtained at 300°C did not significantly affect passivation. The interface-trapping density markedly increased at high annealing temperature (>600°C) and degraded the surface passivation even at a high Qf. Negatively charged or neutral vacancies were found in the samples annealed at 300°C, 500°C, and 750°C using positron annihilation techniques. The Al defect density in the bulk film and the vacancy density near the SiOx/Si interface region decreased with increased temperature. Measurement results of Qf proved that the Al vacancy of the bulk film may not be related to Qf. The defect density in the SiOx region affected the chemical passivation, but other factors may dominantly influence chemical passivation at 750°C. PMID:23452508

  8. A novel active-passive sampling approach for measuring time-averaged concentrations of pollutants in water.

    PubMed

    Amato, Elvio D; Covaci, Adrian; Town, Raewyn M; Hereijgers, Jonas; Bellekens, Ben; Giacometti, Valentina; Breugelmans, Tom; Weyn, Maarten; Dardenne, Freddy; Bervoets, Lieven; Blust, Ronny

    2018-06-14

    Passive sampling with in situ devices offers several advantages over traditional sampling methods (i.e., discrete spot sampling), however, data interpretation from conventional passive samplers is hampered by difficulties in estimating the thickness of the diffusion layer at the sampler/medium interface (δ), often leading to inaccurate determinations of target analyte concentrations. In this study, the performance of a novel device combining active and passive sampling was investigated in the laboratory. The active-passive sampling (APS) device is comprised of a diffusion cell fitted with a pump and a flowmeter. Three receiving phases traditionally used in passive sampling devices (i.e., chelex resin, Oasis HLB, and silicone rubber), were incorporated in the diffusion cell and allowed the simultaneous accumulation of cationic metals, polar, and non-polar organic compounds, respectively. The flow within the diffusion cell was accurately controlled and monitored, and, combined with diffusion coefficients measurements, enabled the average δ to be estimated. Strong agreement between APS and time-averaged total concentrations measured in discrete water samples was found for most of the substances investigated. Accuracies for metals ranged between 87 and 116%, except Cu and Pb (∼50%), whilst accuracies between 64 and 101%, and 92 and 151% were achieved for polar and non-polar organic compounds, respectively. These results indicate that, via a well-defined in situ preconcentration step, the proposed APS approach shows promise for monitoring the concentration of a range of pollutants in water. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. The Effect of Light-Intensity Cycling on Mood and Working Memory in Response to a Randomized, Placebo-Controlled Design.

    PubMed

    Lindheimer, Jacob B; OʼConnor, Patrick J; McCully, Kevin K; Dishman, Rod K

    Prior attempts to measure psychological responses to exercise are potentially limited by a failure to account for participants' expectations, the absence of a valid exercise placebo, and demand characteristics. The purpose of this study was to explore the main and interactive effects of a manipulation designed to increase expectations about the psychological benefits of an acute bout of active, light-intensity (treatment), and passive (placebo) cycling on mood and cognition. Demand characteristics were attenuated during recruitment, informed consent, and interactions with test administrators by communicating to participants that the study purpose was to assess the effects of active and passive cycling on respiration, heart rate, and muscle activation. A repeated-measures, randomized, placebo-controlled design (n = 60) was used with cycling (active, passive) and information (informed, not informed) as between-subjects factors. State anxiety, feelings of energy, and working memory (percent accuracy and reaction time for correct responses) were measured at baseline (time 1), immediately after cycling (time 2) and 20 minutes after cycling (time 3). Most participants did not guess the purpose of the study (~92%) or expect a reduction in state anxiety (85%) or an increase in energy (80%) or cognitive performance (~93%). Mood and cognitive performance were not improved by active or passive cycling (all p values ≥ .12). The methods used here to disguise the experimental hypotheses provide a potential framework for reducing demand characteristics and placebo responses in future investigations of psychological responses to exercise.

  10. Passive immunisation, an old idea revisited: Basic principles and application to modern animal production systems.

    PubMed

    Hedegaard, Chris J; Heegaard, Peter M H

    2016-06-01

    Immunisation by administration of antibodies (immunoglobulins) has been known for more than one hundred years as a very efficient means of obtaining immediate, short-lived protection against infection and/or against the disease-causing effects of toxins from microbial pathogens and from other sources. Thus, due to its rapid action, passive immunisation is often used to treat disease caused by infection and/or toxin exposure. However immunoglobulins may also be administered prior to exposure to infection and/or toxin, although they will not provide long-lasting protection as is seen with active immunisation (vaccination) in which an immunological memory is established by controlled exposure of the host to the pathogen in question. With multi-factorial infectious diseases in production animals, especially those that have proven hard to control by vaccination, the potential of passive immunisation remains big. This review highlights a number of examples on the use of passive immunisation for the control of infectious disease in the modern production of a range of animals, including pigs, cattle, sheep, goat, poultry and fish. Special emphasis is given on the enablement of passive immunisation strategies in these production systems through low cost and ease of use as well as on the sources, composition and purity of immunoglobulin preparations used and their benefits as compared to current measures, including vaccination (also comprising maternal vaccination), antibiotics and feed additives such as spray-dried plasma. It is concluded that provided highly efficient, relatively low-price immunoglobulin products are available, passive immunisation has a clear role in the modern animal production sector as a means of controlling infectious diseases, importantly with a very low risk of causing development of bacterial resistance, thus constituting a real and widely applicable alternative to antibiotics. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Passivity-based Robust Control of Aerospace Systems

    NASA Technical Reports Server (NTRS)

    Kelkar, Atul G.; Joshi, Suresh M. (Technical Monitor)

    2000-01-01

    This report provides a brief summary of the research work performed over the duration of the cooperative research agreement between NASA Langley Research Center and Kansas State University. The cooperative agreement which was originally for the duration the three years was extended by another year through no-cost extension in order to accomplish the goals of the project. The main objective of the research was to develop passivity-based robust control methodology for passive and non-passive aerospace systems. The focus of the first-year's research was limited to the investigation of passivity-based methods for the robust control of Linear Time-Invariant (LTI) single-input single-output (SISO), open-loop stable, minimum-phase non-passive systems. The second year's focus was mainly on extending the passivity-based methodology to a larger class of non-passive LTI systems which includes unstable and nonminimum phase SISO systems. For LTI non-passive systems, five different passification. methods were developed. The primary effort during the years three and four was on the development of passification methodology for MIMO systems, development of methods for checking robustness of passification, and developing synthesis techniques for passifying compensators. For passive LTI systems optimal synthesis procedure was also developed for the design of constant-gain positive real controllers. For nonlinear passive systems, numerical optimization-based technique was developed for the synthesis of constant as well as time-varying gain positive-real controllers. The passivity-based control design methodology developed during the duration of this project was demonstrated by its application to various benchmark examples. These example systems included longitudinal model of an F-18 High Alpha Research Vehicle (HARV) for pitch axis control, NASA's supersonic transport wind tunnel model, ACC benchmark model, 1-D acoustic duct model, piezo-actuated flexible link model, and NASA's Benchmark Active Controls Technology (BACT) Wing model. Some of the stability results for linear passive systems were also extended to nonlinear passive systems. Several publications and conference presentations resulted from this research.

  12. films on silicon at different annealing temperatures

    NASA Astrophysics Data System (ADS)

    Zhao, Yan; Zhou, Chunlan; Zhang, Xiang; Zhang, Peng; Dou, Yanan; Wang, Wenjing; Cao, Xingzhong; Wang, Baoyi; Tang, Yehua; Zhou, Su

    2013-03-01

    Thermal atomic layer-deposited (ALD) aluminum oxide (Al2O3) acquires high negative fixed charge density ( Q f) and sufficiently low interface trap density after annealing, which enables excellent surface passivation for crystalline silicon. Q f can be controlled by varying the annealing temperatures. In this study, the effect of the annealing temperature of thermal ALD Al2O3 films on p-type Czochralski silicon wafers was investigated. Corona charging measurements revealed that the Q f obtained at 300°C did not significantly affect passivation. The interface-trapping density markedly increased at high annealing temperature (>600°C) and degraded the surface passivation even at a high Q f. Negatively charged or neutral vacancies were found in the samples annealed at 300°C, 500°C, and 750°C using positron annihilation techniques. The Al defect density in the bulk film and the vacancy density near the SiO x /Si interface region decreased with increased temperature. Measurement results of Q f proved that the Al vacancy of the bulk film may not be related to Q f. The defect density in the SiO x region affected the chemical passivation, but other factors may dominantly influence chemical passivation at 750°C.

  13. Active and passive fatigue in simulated driving: discriminating styles of workload regulation and their safety impacts.

    PubMed

    Saxby, Dyani J; Matthews, Gerald; Warm, Joel S; Hitchcock, Edward M; Neubauer, Catherine

    2013-12-01

    Despite the known dangers of driver fatigue, it is a difficult construct to study empirically. Different forms of task-induced fatigue may differ in their effects on driver performance and safety. Desmond and Hancock (2001) defined active and passive fatigue states that reflect different styles of workload regulation. In 2 driving simulator studies we investigated the multidimensional subjective states and safety outcomes associated with active and passive fatigue. Wind gusts were used to induce active fatigue, and full vehicle automation to induce passive fatigue. Drive duration was independently manipulated to track the development of fatigue states over time. Participants were undergraduate students. Study 1 (N = 108) focused on subjective response and associated cognitive stress processes, while Study 2 (N = 168) tested fatigue effects on vehicle control and alertness. In both studies the 2 fatigue manipulations produced different patterns of subjective response reflecting different styles of workload regulation, appraisal, and coping. Active fatigue was associated with distress, overload, and heightened coping efforts, whereas passive fatigue corresponded to large-magnitude declines in task engagement, cognitive underload, and reduced challenge appraisal. Study 2 showed that only passive fatigue reduced alertness, operationalized as speed of braking and steering responses to an emergency event. Passive fatigue also increased crash probability, but did not affect a measure of vehicle control. Findings support theories that see fatigue as an outcome of strategies for managing workload. The distinction between active and passive fatigue is important for assessment of fatigue and for evaluating automated driving systems which may induce dangerous levels of passive fatigue. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  14. Online measurement of bead geometry in GMAW-based additive manufacturing using passive vision

    NASA Astrophysics Data System (ADS)

    Xiong, Jun; Zhang, Guangjun

    2013-11-01

    Additive manufacturing based on gas metal arc welding is an advanced technique for depositing fully dense components with low cost. Despite this fact, techniques to achieve accurate control and automation of the process have not yet been perfectly developed. The online measurement of the deposited bead geometry is a key problem for reliable control. In this work a passive vision-sensing system, comprising two cameras and composite filtering techniques, was proposed for real-time detection of the bead height and width through deposition of thin walls. The nozzle to the top surface distance was monitored for eliminating accumulated height errors during the multi-layer deposition process. Various image processing algorithms were applied and discussed for extracting feature parameters. A calibration procedure was presented for the monitoring system. Validation experiments confirmed the effectiveness of the online measurement system for bead geometry in layered additive manufacturing.

  15. Acoustic absorbance measurements in neonates exposed to smoking during pregnancy.

    PubMed

    Pucci, Beatriz Paloma Corrêa; Roque, Nayara Michelle Costa de Freitas; Gamero, Marcella Scigliano; Durante, Alessandra Spada

    2017-04-01

    To analyze acoustic absorbance using wideband tympanometry in neonates exposed to passive smoking during pregnancy. A study comprising 54 neonates in the control group (CG - unexposed) and 19 in the study group (SG - exposed) was carried out. Subjects were submitted to the wideband tympanometry test and subsequent analysis of absorbance of 17 frequencies. Low frequencies had a lower level of absorbance compared to high frequencies for both ambient and peak pressures, with no difference between the groups. No effect of passive smoking on acoustic absorbance measurements in neonates was observed. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Atomic level characterization in corrosion studies

    NASA Astrophysics Data System (ADS)

    Marcus, Philippe; Maurice, Vincent

    2017-06-01

    Atomic level characterization brings fundamental insight into the mechanisms of self-protection against corrosion of metals and alloys by oxide passive films and into how localized corrosion is initiated on passivated metal surfaces. This is illustrated in this overview with selected data obtained at the subnanometre, i.e. atomic or molecular, scale and also at the nanometre scale on single-crystal copper, nickel, chromium and stainless steel surfaces passivated in well-controlled conditions and analysed in situ and/or ex situ by scanning tunnelling microscopy/spectroscopy and atomic force microscopy. A selected example of corrosion modelling by ab initio density functional theory is also presented. The discussed aspects include the surface reconstruction induced by hydroxide adsorption and formation of two-dimensional (hydr)oxide precursors, the atomic structure, orientation and surface hydroxylation of three-dimensional ultrathin oxide passive films, the effect of grain boundaries in polycrystalline passive films acting as preferential sites of passivity breakdown, the differences in local electronic properties measured at grain boundaries of passive films and the role of step edges at the exposed surface of oxide grains on the dissolution of the passive film. This article is part of the themed issue 'The challenges of hydrogen and metals'.

  17. Passive Sampling in Regulatory Chemical Monitoring of Nonpolar Organic Compounds in the Aquatic Environment.

    PubMed

    Booij, Kees; Robinson, Craig D; Burgess, Robert M; Mayer, Philipp; Roberts, Cindy A; Ahrens, Lutz; Allan, Ian J; Brant, Jan; Jones, Lisa; Kraus, Uta R; Larsen, Martin M; Lepom, Peter; Petersen, Jördis; Pröfrock, Daniel; Roose, Patrick; Schäfer, Sabine; Smedes, Foppe; Tixier, Céline; Vorkamp, Katrin; Whitehouse, Paul

    2016-01-05

    We reviewed compliance monitoring requirements in the European Union, the United States, and the Oslo-Paris Convention for the protection of the marine environment of the North-East Atlantic, and evaluated if these are met by passive sampling methods for nonpolar compounds. The strengths and shortcomings of passive sampling are assessed for water, sediments, and biota. Passive water sampling is a suitable technique for measuring concentrations of freely dissolved compounds. This method yields results that are incompatible with the EU's quality standard definition in terms of total concentrations in water, but this definition has little scientific basis. Insufficient quality control is a present weakness of passive sampling in water. Laboratory performance studies and the development of standardized methods are needed to improve data quality and to encourage the use of passive sampling by commercial laboratories and monitoring agencies. Successful prediction of bioaccumulation based on passive sampling is well documented for organisms at the lower trophic levels, but requires more research for higher levels. Despite the existence of several knowledge gaps, passive sampling presently is the best available technology for chemical monitoring of nonpolar organic compounds. Key issues to be addressed by scientists and environmental managers are outlined.

  18. Can passive mobilization provide clinically-relevant brain stimulation? A pilot EEG and NIRS study on healthy subjects.

    PubMed

    Pittaccio, Simone; Garavaglia, Lorenzo; Molteni, Erika; Guanziroli, Eleonora; Zappasodi, Filippo; Beretta, Elena; Strazzer, Sandra; Molteni, Franco; Villa, Elena; Passaretti, Francesca

    2013-01-01

    Lower limb rehabilitation is a fundamental part of post-acute care in neurological disease. Early commencement of active workout is often prevented by paresis, thus physical treatment may be delayed until patients regain some voluntary command of their muscles. Passive mobilization of the affected joints is mostly delivered in order to safeguard tissue properties and shun circulatory problems. The present paper investigates the potential role of early passive motion in stimulating cortical areas of the brain devoted to the control of the lower limb. An electro-mechanical mobilizer for the ankle joint (Toe-Up!) was implemented utilizing specially-designed shape-memory-alloy-based actuators. This device was constructed to be usable by bedridden subjects. Besides, the slowness and gentleness of the imparted motion, make it suitable for patients in a very early stage of their recovery. The mobilizer underwent technical checks to confirm reliability and passed the required safety tests for electric biomedical devices. Four healthy volunteers took part in the pre-clinical phase of the study. The protocol consisted in measuring of brain activity by EEG and NIRS in four different conditions: rest, active dorsiflexion of the ankle, passive mobilization of the ankle, and assisted motion of the same joint. The acquired data were processed to obtain maps of cortical activation, which were then compared. The measurements collected so far show that there is a similar pattern of activity between active and passive/assisted particularly in the contralateral premotor areas. This result, albeit based on very few observations, might suggest that passive motion provides somatosensory afferences that are processed in a similar manner as for voluntary control. Should this evidence be confirmed by further trials on healthy individuals and neurological patients, it could form a basis for a clinical use of early passive exercise in supporting central functional recovery.

  19. Multiple-layered effective medium approximation approach to modeling environmental effects on alumina passivated highly porous silicon nanostructured thin films measured by in-situ Mueller matrix ellipsometry

    NASA Astrophysics Data System (ADS)

    Mock, Alyssa; Carlson, Timothy; VanDerslice, Jeremy; Mohrmann, Joel; Woollam, John A.; Schubert, Eva; Schubert, Mathias

    2017-11-01

    Optical changes in alumina passivated highly porous silicon slanted columnar thin films during controlled exposure to toluene vapor are reported. Electron-beam evaporation glancing angle deposition and subsequent atomic layer deposition are utilized to deposit alumina passivated nanostructured porous silicon thin films. In-situ Mueller matrix generalized spectroscopic ellipsometry in an environmental cell is then used to determine changes in optical properties of the nanostructured thin films by inspection of individual Mueller matrix elements, each of which exhibit sensitivity to adsorption. The use of a multiple-layered effective medium approximation model allows for accurate description of the inhomogeneous nature of toluene adsorption onto alumina passivated highly porous silicon slanted columnar thin films.

  20. Demonstration of Passive Fuel Cell Thermal Management Technology

    NASA Technical Reports Server (NTRS)

    Burke, Kenneth A.; Jakupca, Ian; Colozza, Anthony; Wynne, Robert; Miller, Michael; Meyer, Al; Smith, William

    2012-01-01

    The NASA Glenn Research Center is developing advanced passive thermal management technology to reduce the mass and improve the reliability of space fuel cell systems for the NASA Exploration program. The passive thermal management system relies on heat conduction within highly thermally conductive cooling plates to move the heat from the central portion of the cell stack out to the edges of the fuel cell stack. Using the passive approach eliminates the need for a coolant pump and other cooling loop components within the fuel cell system which reduces mass and improves overall system reliability. Previous development demonstrated the performance of suitable highly thermally conductive cooling plates and integrated heat exchanger technology to collect the heat from the cooling plates (Ref. 1). The next step in the development of this passive thermal approach was the demonstration of the control of the heat removal process and the demonstration of the passive thermal control technology in actual fuel cell stacks. Tests were run with a simulated fuel cell stack passive thermal management system outfitted with passive cooling plates, an integrated heat exchanger and two types of cooling flow control valves. The tests were run to demonstrate the controllability of the passive thermal control approach. Finally, successful demonstrations of passive thermal control technology were conducted with fuel cell stacks from two fuel cell stack vendors.

  1. Power spectrum analysis of cardiovascular variability during passive heating in conscious rats.

    PubMed

    Moura, Anselmo Gomes; Pires, Washington; Leite, Laura Hora Rios; da Cunha, Daise Nunes Queiroz; Peçanha, Tiago; de Lima, Jorge Roberto Peurrot; Natali, Antônio José; Prímola-Gomes, Thales Nicolau

    2016-12-01

    The cardiovascular system plays a direct role in the maintenance of body temperature. Whether passive heating alters cardiovascular autonomic modulation in conscious rats is still unknown. This study investigated the effects of passive heating on systolic blood pressure variability (SBPV) and heart rate variability (HRV) in conscious rats and the involvement of the renin-angiotensin system in the passive heating effects on SBPV and HRV. Fourteen male Wistar rats were randomly assigned to the control group or the losartan treatment group. A catheter was implanted in the left carotid artery to record pulsatile arterial pressure (PAP), and a telemetry sensor was implanted in the abdominal cavity to measure body temperature (T body ). After recovering from surgery, the animals were subjected to a passive heating protocol (35°C; 30min) in resting conditions, during which T body , tail skin temperature and PAP were measured. The mean arterial pressure, systolic and diastolic blood pressure, heart rate, double product (i.e., the product of systolic blood pressure by heart rate), SBPV and HRV were calculated from the PAP. SBPV and HRV were analyzed in terms of both time and frequency domains. Increases in the thermoregulatory and cardiovascular parameters were observed during passive heating in both groups, and those increases were reflected in the higher time and frequency domains of the SBPV. However, passive heating was not effective in altering HRV. Passive heating altered SBPV but not HRV in conscious rats when they were treated with losartan. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Synthesis of Optimal Constant-Gain Positive-Real Controllers for Passive Systems

    NASA Technical Reports Server (NTRS)

    Mao, Y.; Kelkar, A. G.; Joshi, S. M.

    1999-01-01

    This paper presents synthesis methods for the design of constant-gain positive real controllers for passive systems. The results presented in this paper, in conjunction with the previous work by the authors on passification of non-passive systems, offer a useful synthesis tool for the design of passivity-based robust controllers for non-passive systems as well. Two synthesis approaches are given for minimizing an LQ-type performance index, resulting in optimal controller gains. Two separate algorithms, one for each of these approaches, are given. The synthesis techniques are demonstrated using two numerical examples: control of a flexible structure and longitudinal control of a fighter aircraft.

  3. Enhanced damping for bridge cables using a self-sensing MR damper

    NASA Astrophysics Data System (ADS)

    Chen, Z. H.; Lam, K. H.; Ni, Y. Q.

    2016-08-01

    This paper investigates enhanced damping for protecting bridge stay cables from excessive vibration using a newly developed self-sensing magnetorheological (MR) damper. The semi-active control strategy for effectively operating the self-sensing MR damper is formulated based on the linear-quadratic-Gaussian (LQG) control by further considering a collocated control configuration, limited measurements and nonlinear damper dynamics. Due to its attractive feature of sensing-while-damping, the self-sensing MR damper facilitates the collocated control. On the other hand, only the sensor measurements from the self-sensing device are employed in the feedback control. The nonlinear dynamics of the self-sensing MR damper, represented by a validated Bayesian NARX network technique, are further accommodated in the control formulation to compensate for its nonlinearities. Numerical and experimental investigations are conducted on stay cables equipped with the self-sensing MR damper operated in passive and semi-active control modes. The results verify that the collocated self-sensing MR damper facilitates smart damping for inclined cables employing energy-dissipative LQG control with only force and displacement measurements at the damper. It is also demonstrated that the synthesis of nonlinear damper dynamics in the LQG control enhances damping force tracking efficiently, explores the features of the self-sensing MR damper, and achieves better control performance over the passive MR damping control and the Heaviside step function-based LQG control that ignores the damper dynamics.

  4. In-house experiments in large space structures at the Air Force Wright Aeronautical Laboratories Flight Dynamics Laboratory

    NASA Technical Reports Server (NTRS)

    Gordon, Robert W.; Ozguner, Umit; Yurkovich, Steven

    1989-01-01

    The Flight Dynamics Laboratory is committed to an in-house, experimental investigation of several technical areas critical to the dynamic performance of future Air Force large space structures. The advanced beam experiment was successfully completed and provided much experience in the implementation of active control approaches on real hardware. A series of experiments is under way in evaluating ground test methods on the 12 meter trusses with significant passive damping. Ground simulated zero-g response data from the undamped truss will be compared directly with true zero-g flight test data. The performance of several leading active control approaches will be measured and compared on one of the trusses in the presence of significant passive damping. In the future, the PACOSS dynamic test article will be set up as a test bed for the evaluation of system identification and control techniques on a complex, representative structure with high modal density and significant passive damping.

  5. Increased muscle belly and tendon stiffness in patients with Parkinson's disease, as measured by myotonometry.

    PubMed

    Marusiak, Jarosław; Jaskólska, Anna; Budrewicz, Sławomir; Koszewicz, Magdalena; Jaskólski, Artur

    2011-09-01

    Based on Davis's law, greater tonus of the muscle belly in individuals with Parkinson's disease can create greater tension in the tendon, leading to structural adjustment and an increase in tendon stiffness. Our study aimed to separately assess passive stiffness in the muscle belly and tendon in medicated patients with Parkinson's disease, using myotonometry. We tested 12 patients with Parkinson's disease and 12 healthy matched controls. Passive stiffness of muscle belly and tendon was estimated by myotonometry, electromyography, and mechanomyography in relaxed biceps and triceps brachii muscles. Compared with controls, patients with Parkinson's disease had higher stiffness in the muscle belly and tendon of the biceps brachii and in the tendon of the triceps brachii. In patients with Parkinson's disease, there was a positive correlation between muscle belly stiffness and parkinsonian rigidity in the biceps brachii. Patients with Parkinson's disease have higher passive stiffness of the muscle belly and tendon than healthy matched controls. Copyright © 2011 Movement Disorder Society.

  6. Integrated active and passive control design methodology for the LaRC CSI evolutionary model

    NASA Technical Reports Server (NTRS)

    Voth, Christopher T.; Richards, Kenneth E., Jr.; Schmitz, Eric; Gehling, Russel N.; Morgenthaler, Daniel R.

    1994-01-01

    A general design methodology to integrate active control with passive damping was demonstrated on the NASA LaRC CSI Evolutionary Model (CEM), a ground testbed for future large, flexible spacecraft. Vibration suppression controllers designed for Line-of Sight (LOS) minimization were successfully implemented on the CEM. A frequency-shaped H2 methodology was developed, allowing the designer to specify the roll-off of the MIMO compensator. A closed loop bandwidth of 4 Hz, including the six rigid body modes and the first three dominant elastic modes of the CEM was achieved. Good agreement was demonstrated between experimental data and analytical predictions for the closed loop frequency response and random tests. Using the Modal Strain Energy (MSE) method, a passive damping treatment consisting of 60 viscoelastically damped struts was designed, fabricated and implemented on the CEM. Damping levels for the targeted modes were more than an order of magnitude larger than for the undamped structure. Using measured loss and stiffness data for the individual damped struts, analytical predictions of the damping levels were very close to the experimental values in the (1-10) Hz frequency range where the open loop model matched the experimental data. An integrated active/passive controller was successfully implemented on the CEM and was evaluated against an active-only controller. A two-fold increase in the effective control bandwidth and further reductions of 30 percent to 50 percent in the LOS RMS outputs were achieved compared to an active-only controller. Superior performance was also obtained compared to a High-Authority/Low-Authority (HAC/LAC) controller.

  7. Effect of passive sensitization on the mechanical activity of human isolated bronchial smooth muscle induced by substance P, neurokinin A and VIP.

    PubMed Central

    Ben-Jebria, A.; Marthan, R.; Rossetti, M.; Savineau, J. P.

    1993-01-01

    1. The effect of passive sensitization on the mechanical activity of human isolated bronchial smooth muscle induced by the following neuropeptides substance P (SP), neurokinin A (NKA) and vasoactive intestinal peptide (VIP) was studied both in the absence and in the presence of the neutral endopeptidase (NEP) inhibitor, phosphoramidon. 2. Cumulative concentration-response curves (CCRC) to these neuropeptides were constructed in human passively sensitized isolated bronchial rings and compared to those in paired controls. Passively sensitized human isolated bronchial rings were tissues incubated overnight in serum from asthmatic patients atopic to Dermatophagoides pteronyssinus and paired controls were tissues originating from the same lung specimens but incubated overnight in serum from healthy donors. 3. In the absence of phosphoramidon, passive sensitization significantly increased the amplitude of the contractile responses to SP and NKA including that to the maximal concentration given from 50 +/- 5% to 76 +/- 6% (n = 5, P < 0.05) and from 70 +/- 7% to 101 +/- 6% (n = 5, P < 0.05) of the maximal response to acetylcholine, respectively. Passive sensitization significantly shifted to the left the CCRC for both tachykinins as measured by the geometric means dose-ratios which were 8.5 (95% confidence limits (CL): 3.1-13.9) and 7.3 (95% CL: 4.2-10.3) for SP and NKA, respectively.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:7684296

  8. Re-Active Passive devices for control of noise transmission through a panel

    NASA Astrophysics Data System (ADS)

    Carneal, James P.; Giovanardi, Marco; Fuller, Chris R.; Palumbo, Dan

    2008-01-01

    Re-Active Passive devices have been developed to control low-frequency (<1000 Hz) noise transmission through a panel. These devices use a combination of active, re-active, and passive technologies packaged into a single unit to control a broad frequency range utilizing the strength of each technology over its best suited frequency range. The Re-Active Passive device uses passive constrained layer damping to cover relatively high-frequency range (>150 Hz), reactive distributed vibration absorber to cover the medium-frequency range (50-200 Hz), and active control for controlling low frequencies (<150 Hz). The actuator was applied to control noise transmission through a panel mounted in the Transmission Loss Test Facility at Virginia Tech. Experimental results are presented for the bare panel, and combinations of passive treatment, reactive treatment, and active control. Results indicate that three Re-Active Passive devices were able to increase the overall broadband (15-1000 Hz) transmission loss by 9.4 dB. These three devices added a total of 285 g to the panel mass of 6.0 kg, or approximately 5%, not including control electronics.

  9. Mechanical behaviour of hamstring muscles in low-back pain patients and control subjects.

    PubMed

    Tafazzoli, F; Lamontagne, M

    1996-01-01

    The purpose of this study was to measure and compare the passive elastic moment, the stiffness and the damping coefficient of the hip joint, as functions of the hip and knee joint angles in men with and without low-back pain. Two conventional tests, the straight-leg-raising test and the trunk forward flexion, were also performed and compared between these subjects. The passive elastic moment was measured using an isokinetic device in the passive mode. This device raised the lower limb from the horizontal position to the straight-leg-raising angle at a slow and constant angular velocity. A custom-made splint connected with the lever arm of the isokinetic device maintained the knee in extension and the ankle in the neutral position. The damping coefficient of the hip joint was measured for 0, 15, 45, 60, 75 and 90% of straight leg raising angle of each subject, using the suspension method based on small oscillation theory. To ensure that muscles were inactive during the passive hip moment tests, muscle activity was monitored with surface EMG. The stiffness was computed as the ratio of the change in passive elastic moment to the change in the hip angle. The passive elastic moment, the stiffness and the normalized trunk flexion were significantly different between the two groups respectively. There was, however, no difference between the two groups in the results of straight-leg-raise and damping coefficient of the hip. The passive elastic moment was a nonlinear function of the hip flexion angle and showed large intersubject differences, especially as the joint limit was approached. The damping coefficient was a polynomial function of the hip flexion angle. The measured variables were analysed using a discriminant function and it was shown that the two groups were clearly discriminable in a meaningful manner.

  10. The effect of continuous passive motion and sling exercise training on clinical and functional outcomes following total knee arthroplasty: a randomized active-controlled clinical study.

    PubMed

    Mau-Moeller, Anett; Behrens, Martin; Finze, Susanne; Bruhn, Sven; Bader, Rainer; Mittelmeier, Wolfram

    2014-05-09

    The parallel-group randomized active-controlled clinical study was conducted to compare the effectiveness of two in-hospital range of motion (ROM) exercise programs following total knee arthroplasty (TKA). Continuous passive motion (CPM) is frequently used to increase ROM and improve postoperative recovery despite little conclusive scientific evidence. In contrast, a new active sling-based ROM therapy requires the activation of the knee joint muscles and dynamic joint stabilization. It was hypothesized that higher demands on muscle strength and muscle coordination during sling exercise training (ST) might be advantageous for early recovery following TKA. A total of 125 patients undergoing primary TKA were assessed for eligibility. Thirty-eight patients were randomly assigned to receive ST or CPM (control intervention) during hospital stay. Patients were assessed before TKA for baseline measurement (pretest), 1 day before discharge (posttest) and 3 months after TKA (follow-up). The passive knee flexion range of motion (pFL) was the primary outcome measure. Secondary outcome measures included active knee flexion range of motion, active and passive knee extension ROM, static postural control, physical activity, pain, length of hospital stay as well as clinical, functional and quality-of-life outcomes (SF-36, HSS and WOMAC scores). Data were analyzed according to the intention-to-treat principle. Differences between the groups were tested for significance by the unpaired Student's t test or an analysis of covariance (ANCOVA) adjusted for baseline, weight, sex, age, pain and physical activity. A between-group difference could be determined at posttest. The pFL was significantly higher by 6.0° (95% CI 0.9 to 11.2°; P = 0.022) in the ST group. No difference between groups in pFL was documented at follow-up. Furthermore, no significant differences could be observed for any secondary outcome measure at posttest and follow-up. ST seems to have a clinically relevant beneficial short-term effect on pFL compared to CPM. The results support the implementation of ST in rehabilitation programs following TKA. Therapy, level 2b.

  11. The relationship between cell phone use and management of driver fatigue: It's complicated.

    PubMed

    Saxby, Dyani Juanita; Matthews, Gerald; Neubauer, Catherine

    2017-06-01

    Voice communication may enhance performance during monotonous, potentially fatiguing driving conditions (Atchley & Chan, 2011); however, it is unclear whether safety benefits of conversation are outweighed by costs. The present study tested whether personalized conversations intended to simulate hands-free cell phone conversation may counter objective and subjective fatigue effects elicited by vehicle automation. A passive fatigue state (Desmond & Hancock, 2001), characterized by disengagement from the task, was induced using full vehicle automation prior to drivers resuming full control over the driving simulator. A conversation was initiated shortly after reversion to manual control. During the conversation an emergency event occurred. The fatigue manipulation produced greater task disengagement and slower response to the emergency event, relative to a control condition. Conversation did not mitigate passive fatigue effects; rather, it added worry about matters unrelated to the driving task. Conversation moderately improved vehicle control, as measured by SDLP, but it failed to counter fatigue-induced slowing of braking in response to an emergency event. Finally, conversation appeared to have a hidden danger in that it reduced drivers' insights into performance impairments when in a state of passive fatigue. Automation induced passive fatigue, indicated by loss of task engagement; yet, simulated cell phone conversation did not counter the subjective automation-induced fatigue. Conversation also failed to counter objective loss of performance (slower braking speed) resulting from automation. Cell phone conversation in passive fatigue states may impair drivers' awareness of their performance deficits. Practical applications: Results suggest that conversation, even using a hands-free device, may not be a safe way to reduce fatigue and increase alertness during transitions from automated to manual vehicle control. Copyright © 2017 Elsevier Ltd and National Safety Council. All rights reserved.

  12. Control of Flow Structure on Non-Slender Delta Wing: Bio-inspired Edge Modifications, Passive Bleeding, and Pulsed Blowing

    NASA Astrophysics Data System (ADS)

    Yavuz, Mehmet Metin; Celik, Alper; Cetin, Cenk

    2016-11-01

    In the present study, different flow control approaches including bio-inspired edge modifications, passive bleeding, and pulsed blowing are introduced and applied for the flow over non-slender delta wing. Experiments are conducted in a low speed wind tunnel for a 45 degree swept delta wing using qualitative and quantitative measurement techniques including laser illuminated smoke visualization, particle image velocimety (PIV), and surface pressure measurements. For the bio-inspired edge modifications, the edges of the wing are modified to dolphin fluke geometry. In addition, the concept of flexion ratio, a ratio depending on the flexible length of animal propulsors such as wings, is introduced. For passive bleeding, directing the free stream air from the pressure side of the planform to the suction side of the wing is applied. For pulsed blowing, periodic air injection through the leading edge of the wing is performed in a square waveform with 25% duty cycle at different excitation frequencies and compared with the steady and no blowing cases. The results indicate that each control approach is quite effective in terms of altering the overall flow structure on the planform. However, the success level, considering the elimination of stall or delaying the vortex breakdown, depends on the parameters in each method.

  13. Handbook on passive thermal control coatings

    NASA Technical Reports Server (NTRS)

    Mookherji, T. K.; Hayes, J. D.

    1973-01-01

    A handbook of passive thermal control surfaces data pertaining to the heat transfer requirements of spacecraft is presented. Passive temperature control techniques and the selection of control surfaces are analyzed. The space environmental damage mechanisms in passive thermal control surfaces are examined. Data on the coatings for which technical information is available are presented in tabular form. Emphasis was placed on consulting only those references where the experimental simulation of the space environment appeared to be more appropriate.

  14. Tension-referenced measures of gastrocnemius slack length and stiffness in Parkinson's disease.

    PubMed

    Tan, Benedict; Double, Kay L; Burne, John; Diong, Joanna

    2016-12-01

    It is not known how passive muscle length and stiffness contribute to rigidity in Parkinson's disease. The objective of this study was to compare passive gastrocnemius muscle-tendon slack length and stiffness at known tension in Parkinson's disease subjects with ankle rigidity and in able-bodied people. Passive ankle torque-angle curves were obtained from 15 Parkinson's disease subjects with rigidity and 15 control subjects. Torque-angle data were used to derive passive gastrocnemius length-tension data and calculate slack length and stiffness of the gastrocnemius muscle. Between-group comparisons were made with linear models. Gastrocnemius muscle-tendon slack lengths (adjusted between-group difference, 0.01 m; 95% CI, -0.02 to 0.04 m; P = 0.37) and stiffness (adjusted between-group difference, 15.7 m -1 ; 95% CI, -8.5 to 39.9 m -1 ; P = 0.19) were not significantly different between groups. Parkinson's disease subjects with ankle rigidity did not have significantly shorter or stiffer gastrocnemius muscles compared with control subjects. © 2016 International Parkinson and Movement Disorder Society. © 2016 International Parkinson and Movement Disorder Society.

  15. Time domain passivity controller for 4-channel time-delay bilateral teleoperation.

    PubMed

    Rebelo, Joao; Schiele, Andre

    2015-01-01

    This paper presents an extension of the time-domain passivity control approach to a four-channel bilateral controller under the effects of time delays. Time-domain passivity control has been used successfully to stabilize teleoperation systems with position-force and position-position controllers; however, the performance with such control architectures is sub-optimal both with and without time delays. This work extends the network representation of the time-domain passivity controller to the four-channel architecture, which provides perfect transparency to the user without time delay. The proposed architecture is based on modelling the controllers as dependent voltage sources and using only series passivity controllers. The obtained results are shown on a one degree-of-freedom setup and illustrate the stabilization behaviour of the proposed controller when time delay is present in the communication channel.

  16. Determinants of passive smoking in children in Edinburgh, Scotland.

    PubMed Central

    Jarvis, M J; Strachan, D P; Feyerabend, C

    1992-01-01

    OBJECTIVES. Using saliva cotinine as a quantitative marker, we examined the contribution of factors other than parental smoking to children's passive exposure to tobacco smoke. METHODS. Saliva specimens from a random sample of 734 7-year-old schoolchildren in Edinburgh, Scotland, were analyzed for cotinine. Their parents completed a questionnaire covering smoking habits and conditions in the home. RESULTS. A number of independent predictors of cotinine were identified in addition to the main one of smoking by household members. These predictors included home ownership, social class, day of the week, season of the year, number of parents present, crowding in the home, the number of children in the household, and sex. Cotinine was higher in children from less advantaged backgrounds, during winter, on Mondays, in girls, and when fewer other children were present. The effects were similar between children from nonsmoking and smoking homes. CONCLUSIONS. Questionnaire measures of parental smoking are insufficient to fully characterize young children's exposure to passive smoking. Because socioeconomic variables contribute to measured exposure, passive-smoking studies that treat class as a confounder and control for it may be overcontrolling. PMID:1503162

  17. The influence of lower limb impairments on RaceRunning performance in athletes with hypertonia, ataxia or athetosis.

    PubMed

    van der Linden, Marietta L; Jahed, Sadaf; Tennant, Nicola; Verheul, Martine H G

    2018-03-01

    RaceRunning enables athletes with limited or no walking ability to propel themselves independently using a three-wheeled running bike that has a saddle and a chest plate for support but no pedals. For RaceRunning to be included as a Para athletics event, an evidence-based classification system is required. Therefore, the aim of this study was to assess the association between a range of impairment measures and RaceRunning performance. The following impairment measures were recorded: lower limb muscle strength assessed using Manual Muscle Testing (MMT), selective voluntary motor control assessed using the Selective Control Assessment of the Lower Extremity (SCALE), spasticity recorded using both the Australian Spasticity Assessment Score (ASAS) and Modified Ashworth Scale (MAS), passive range of motion (ROM) of the lower extremities and the maximum static step length achieved on a stationary bike (MSSL). Associations between impairment measures and 100-meter race speed were assessed using Spearman's correlation coefficients. Sixteen male and fifteen female athletes (27 with cerebral palsy), aged 23 (SD = 7) years, Gross Motor Function Classification System levels ranging from II to V, participated. The MSSL averaged over both legs and the ASAS, MAS, SCALE, and MMT summed over all joints and both legs, significantly correlated with 100 m race performance (rho: 0.40-0.54). Passive knee extension was the only ROM measure that was significantly associated with race speed (rho = 0.48). These results suggest that lower limb spasticity, isometric leg strength, selective voluntary motor control and passive knee extension impact performance in RaceRunning athletes. This supports the potential use of these measures in a future evidence-based classification system. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Active control of an innovative seat suspension system with acceleration measurement based friction estimation

    NASA Astrophysics Data System (ADS)

    Ning, Donghong; Sun, Shuaishuai; Li, Hongyi; Du, Haiping; Li, Weihua

    2016-12-01

    In this paper, an innovative active seat suspension system for vehicles is presented. This seat suspension prototype is built with two low cost actuators each of which has one rotary motor and one gear reducer. A H∞ controller with friction compensation is designed for the seat suspension control system where the friction is estimated and compensated based on the measurement of seat acceleration. This principal aim of this research was to control the low frequency vibration transferred or amplified by the vehicle (chassis) suspension, and to maintain the passivity of the seat suspension at high frequency (isolation vibration) while taking into consideration the trade-off between the active seat suspension cost and its high frequency performance. Sinusoidal excitations of 1-4.5 Hz were applied to test the active seat suspension both when controlled and when uncontrolled and this is compared with a well-tuned passive heavy duty vehicle seat suspension. The results indicate the effectiveness of the proposed control algorithm within the tested frequencies. Further tests were conducted using the excitations generated from a quarter-car model under bump and random road profiles. The bump road tests indicate the controlled active seat suspension has good transient response performance. The Power Spectral Density (PSD) method and ISO 2631-1 standards were applied to analyse the seat suspension's acceleration under random road conditions. Although some low magnitude and high frequency noise will inevitably be introduced by the active system, the weighted-frequency Root Mean Square (RMS) acceleration shows that this may not have a large effect on ride comfort. In fact, the ride comfort is improved from being an 'a little uncomfortable' to a 'not uncomfortable' level when compared with the well-tuned passive seat suspension. This low cost active seat suspension design and the proposed controller with the easily measured feedback signals are very practical for real applications.

  19. Advanced Aerodynamic Design of Passive Porosity Control Effectors

    NASA Technical Reports Server (NTRS)

    Hunter, Craig A.; Viken, Sally A.; Wood, Richard M.; Bauer, Steven X. S.

    2001-01-01

    This paper describes aerodynamic design work aimed at developing a passive porosity control effector system for a generic tailless fighter aircraft. As part of this work, a computational design tool was developed and used to layout passive porosity effector systems for longitudinal and lateral-directional control at a low-speed, high angle of attack condition. Aerodynamic analysis was conducted using the NASA Langley computational fluid dynamics code USM3D, in conjunction with a newly formulated surface boundary condition for passive porosity. Results indicate that passive porosity effectors can provide maneuver control increments that equal and exceed those of conventional aerodynamic effectors for low-speed, high-alpha flight, with control levels that are a linear function of porous area. This work demonstrates the tremendous potential of passive porosity to yield simple control effector systems that have no external moving parts and will preserve an aircraft's fixed outer mold line.

  20. Electronic gaming as pain distraction

    PubMed Central

    Jameson, Eleanor; Trevena, Judy; Swain, Nic

    2011-01-01

    The current study investigated whether active distraction reduces participants’ experience of pain more than passive distraction during a cold pressor task. In the first experiment, 60 participants were asked to submerge their hand in cold (2°C) water for as long as they could tolerate. They did this with no distraction, and then with active (electronic gaming system) and passive (television) distraction, in randomly assigned order. Tolerance time, pain intensity ratings and task absorption ratings were measured for each condition. A second experiment attempted to control for participants’ expectations about the effects of distraction on pain. Forty participants underwent the same experimental procedure, but were given verbal suggestions about the effects of distraction by the experimenter before each distraction condition. Participants in both experiments had a significantly higher pain tolerance and reported less pain with the active distraction compared with passive or no distraction. Participants reported being more absorbed, and were significantly more willing to do the task again when they had the active distraction compared with both passive distraction and no distraction. They also had more enjoyment, less anxiety and greater reduction in pain with active distraction than with passive distraction. There was no effect of suggestion. These experiments offer further support for the use of electronic games as a method of pain control. PMID:21369538

  1. Electronic gaming as pain distraction.

    PubMed

    Jameson, Eleanor; Trevena, Judy; Swain, Nic

    2011-01-01

    The current study investigated whether active distraction reduces participants' experience of pain more than passive distraction during a cold pressor task. In the first experiment, 60 participants were asked to submerge their hand in cold (2°C) water for as long as they could tolerate. They did this with no distraction, and then with active (electronic gaming system) and passive (television) distraction, in randomly assigned order. Tolerance time, pain intensity ratings and task absorption ratings were measured for each condition. A second experiment attempted to control for participants' expectations about the effects of distraction on pain. Forty participants underwent the same experimental procedure, but were given verbal suggestions about the effects of distraction by the experimenter before each distraction condition. Participants in both experiments had a significantly higher pain tolerance and reported less pain with the active distraction compared with passive or no distraction. Participants reported being more absorbed, and were significantly more willing to do the task again when they had the active distraction compared with both passive distraction and no distraction. They also had more enjoyment, less anxiety and greater reduction in pain with active distraction than with passive distraction. There was no effect of suggestion. These experiments offer further support for the use of electronic games as a method of pain control.

  2. Effects of myofascial release leg pull and sagittal plane isometric contract-relax techniques on passive straight-leg raise angle.

    PubMed

    Hanten, W P; Chandler, S D

    1994-09-01

    Experimental evidence does not currently exist to support the claims of clinical effectiveness for myofascial release techniques. This presents an obvious need to document the effects of myofascial release. The purpose of this study was to compare the effects of two techniques, sagittal plane isometric contract-relax and myofascial release leg pull for increasing hip flexion range of motion (ROM) as measured by the angle of passive straight-leg raise. Seventy-five nondisabled, female subjects 18-29 years of age were randomly assigned to contract-relax, leg pull, or control groups. Pretest hip flexion ROM was measured for each subject's right hip with a passive straight-leg raise test using a fluid-filled goniometer. Subjects in the treatment groups received either contract-relax or leg pull treatment applied to the right lower extremity; subjects in the control group remained supine quietly for 5 minutes. Following treatment, posttest straight-leg raise measurements were performed. A one-way analysis of variance followed by a Newman-Keuls post hoc comparison of mean gain scores showed that subjects receiving contract-relax treatment increased their ROM significantly more than those who received leg pull treatment, and the increase in ROM of subjects in both treatment groups was significantly higher than those of the control group. The results suggest that while both contract-relax and leg pull techniques can significantly increase hip flexion ROM in normal subjects, contract-relax treatment may be more effective and efficient than leg pull treatment.

  3. 40 CFR 194.43 - Passive institutional controls.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., design, and contents of the disposal system. Such measures shall include: (1) Identification of the controlled area by markers that have been designed and will be fabricated and emplaced to be as permanent as... system; (ii) The design of the disposal system; (iii) The nature and hazard of the waste; (iv) Geologic...

  4. 40 CFR 194.43 - Passive institutional controls.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., design, and contents of the disposal system. Such measures shall include: (1) Identification of the controlled area by markers that have been designed and will be fabricated and emplaced to be as permanent as... system; (ii) The design of the disposal system; (iii) The nature and hazard of the waste; (iv) Geologic...

  5. Sway‐dependent changes in standing ankle stiffness caused by muscle thixotropy

    PubMed Central

    Sakanaka, Tania E.; Lakie, Martin

    2016-01-01

    Key points The passive stiffness of the calf muscles contributes to standing balance, although the properties of muscle tissue are highly labile.We investigated the effect of sway history upon intrinsic ankle stiffness and demonstrated reductions in stiffness of up to 43% during conditions of increased baseline sway.This sway dependence was most apparent when using low amplitude stiffness‐measuring perturbations, and the short‐range stiffness component was smaller during periods of high sway.These characteristics are consistent with the thixotropic properties of the calf muscles causing the observed changes in ankle stiffness.Periods of increased sway impair the passive stabilization of standing, demanding more active neural control of balance. Abstract Quiet standing is achieved through a combination of active and passive mechanisms, consisting of neural control and intrinsic mechanical stiffness of the ankle joint, respectively. The mechanical stiffness is partly determined by the calf muscles. However, the viscoelastic properties of muscle are highly labile, exhibiting a strong dependence on movement history. By measuring the effect of sway history upon ankle stiffness, the present study determines whether this lability has consequences for the passive stabilization of human standing. Ten subjects stood quietly on a rotating platform whose axis was collinear with the ankle joint. Ankle sway was increased by slowly tilting this platform in a random fashion, or decreased by fixing the body to a board. Ankle stiffness was measured by using the same platform to simultaneously apply small, brief perturbations (<0.6 deg; 140 ms) at the same time as the resulting torque response was recorded. The results show that increasing sway reduces ankle stiffness by up to 43% compared to the body‐fixed condition. Normal quiet stance was associated with intermediate values. The effect was most apparent when using smaller perturbation amplitudes to measure stiffness (0.1 vs. 0.6 deg). Furthermore, torque responses exhibited a biphasic pattern, consisting of an initial steep rise followed by a shallower increase. This transition occurred earlier during increased levels of ankle sway. These results are consistent with a movement‐dependent change in passive ankle stiffness caused by thixotropic properties of the calf muscle. The consequence is to place increased reliance upon active neural control during times when increased sway renders ankle stiffness low. PMID:26607292

  6. A programmable broadband low frequency active vibration isolation system for atom interferometry.

    PubMed

    Tang, Biao; Zhou, Lin; Xiong, Zongyuan; Wang, Jin; Zhan, Mingsheng

    2014-09-01

    Vibration isolation at low frequency is important for some precision measurement experiments that use atom interferometry. To decrease the vibrational noise caused by the reflecting mirror of Raman beams in atom interferometry, we designed and demonstrated a compact stable active low frequency vibration isolation system. In this system, a digital control subsystem is used to process and feedback the vibration measured by a seismometer. A voice coil actuator is used to control and cancel the motion of a commercial passive vibration isolation platform. With the help of field programmable gate array-based control subsystem, the vibration isolation system performed flexibly and accurately. When the feedback is on, the intrinsic resonance frequency of the system will change from 0.8 Hz to about 0.015 Hz. The vertical vibration (0.01-10 Hz) measured by the in-loop seismometer is reduced by an additional factor of up to 500 on the basis of a passive vibration isolation platform, and we have proved the performance by adding an additional seismometer as well as applying it in the atom interferometry experiment.

  7. Investigation of remote sensing techniques of measuring soil moisture

    NASA Technical Reports Server (NTRS)

    Newton, R. W. (Principal Investigator); Blanchard, A. J.; Nieber, J. L.; Lascano, R.; Tsang, L.; Vanbavel, C. H. M.

    1981-01-01

    Major activities described include development and evaluation of theoretical models that describe both active and passive microwave sensing of soil moisture, the evaluation of these models for their applicability, the execution of a controlled field experiment during which passive microwave measurements were acquired to validate these models, and evaluation of previously acquired aircraft microwave measurements. The development of a root zone soil water and soil temperature profile model and the calibration and evaluation of gamma ray attenuation probes for measuring soil moisture profiles are considered. The analysis of spatial variability of soil information as related to remote sensing is discussed as well as the implementation of an instrumented field site for acquisition of soil moisture and meteorologic information for use in validating the soil water profile and soil temperature profile models.

  8. Precise fiber length measurement using harmonic detection of phase-locked cavity modes

    NASA Astrophysics Data System (ADS)

    Terra, Osama

    2018-06-01

    In this paper, precise length measurements of optical fibers are performed by employing harmonic detection of the pulse-train frequency of a passively mode-locked fiber laser. This frequency is proportional to the length of the laser cavity in which the measured fiber is installed. Our proposed technique enables length measurement of long fibers from 1 to 40 km with precision from 0.4 to 8 mm and short fibers of few meters with precision as low as 26 μm. Such superior precision is achieved not only by the selection of higher harmonics of up to 1410, but also by the careful control of the wavelength at which the passive mode-locking occur, because of the broadband nature of the used gain medium.

  9. Lumbopelvic Core Stabilization Exercise and Pain Modulation Among Individuals with Chronic Nonspecific Low Back Pain.

    PubMed

    Paungmali, Aatit; Joseph, Leonard H; Sitilertpisan, Patraporn; Pirunsan, Ubon; Uthaikhup, Sureeporn

    2017-11-01

    Lumbopelvic stabilization training (LPST) may provide therapeutic benefits on pain modulation in chronic nonspecific low back pain conditions. This study aimed to examine the effects of LPST on pain threshold and pain intensity in comparison with the passive automated cycling intervention and control intervention among patients with chronic nonspecific low back pain. A within-subject, repeated-measures, crossover randomized controlled design was conducted among 25 participants (7 males and 18 females) with chronic nonspecific low back pain. All the participants received 3 different types of experimental interventions, which included LPST, the passive automated cycling intervention, and the control intervention randomly, with 48 hours between the sessions. The pressure pain threshold (PPT), hot-cold pain threshold, and pain intensity were estimated before and after the interventions. Repeated-measures analysis of variance showed that LPST provided therapeutic effects as it improved the PPT beyond the placebo and control interventions (P < 0.01). The pain intensity under the LPST condition was significantly better than that under the passive automated cycling intervention and controlled intervention (P < 0.001). Heat pain threshold under the LPST condition also showed a significant trend of improvement beyond the control (P < 0.05), but no significant effects on cold pain threshold were evident. Lumbopelvic stabilization training may provide therapeutic effects by inducing pain modulation through an improvement in the pain threshold and reduction in pain intensity. LPST may be considered as part of the management programs for treatment of chronic low back pain. © 2017 World Institute of Pain.

  10. Effect of water-based recovery on blood lactate removal after high-intensity exercise.

    PubMed

    Lucertini, Francesco; Gervasi, Marco; D'Amen, Giancarlo; Sisti, Davide; Rocchi, Marco Bruno Luigi; Stocchi, Vilberto; Benelli, Piero

    2017-01-01

    This study assessed the effectiveness of water immersion to the shoulders in enhancing blood lactate removal during active and passive recovery after short-duration high-intensity exercise. Seventeen cyclists underwent active water- and land-based recoveries and passive water and land-based recoveries. The recovery conditions lasted 31 minutes each and started after the identification of each cyclist's blood lactate accumulation peak, induced by a 30-second all-out sprint on a cycle ergometer. Active recoveries were performed on a cycle ergometer at 70% of the oxygen consumption corresponding to the lactate threshold (the control for the intensity was oxygen consumption), while passive recoveries were performed with subjects at rest and seated on the cycle ergometer. Blood lactate concentration was measured 8 times during each recovery condition and lactate clearance was modeled over a negative exponential function using non-linear regression. Actual active recovery intensity was compared to the target intensity (one sample t-test) and passive recovery intensities were compared between environments (paired sample t-tests). Non-linear regression parameters (coefficients of the exponential decay of lactate; predicted resting lactates; predicted delta decreases in lactate) were compared between environments (linear mixed model analyses for repeated measures) separately for the active and passive recovery modes. Active recovery intensities did not differ significantly from the target oxygen consumption, whereas passive recovery resulted in a slightly lower oxygen consumption when performed while immersed in water rather than on land. The exponential decay of blood lactate was not significantly different in water- or land-based recoveries in either active or passive recovery conditions. In conclusion, water immersion at 29°C would not appear to be an effective practice for improving post-exercise lactate removal in either the active or passive recovery modes.

  11. Hood River Passive House, Hood River, Oregon (Fact Sheet)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None, None

    2014-02-01

    The Hood River Passive Project was developed by Root Design Build of Hood River Oregon using the Passive House Planning Package (PHPP) to meet all of the requirements for certification under the European Passive House standards. The Passive House design approach has been gaining momentum among residential designers for custom homes and BEopt modeling indicates that these designs may actually exceed the goal of the U.S. Department of Energy's (DOE) Building America program to "reduce home energy use by 30%-50%" (compared to 2009 energy codes for new homes). This report documents the short term test results of the Shift Housemore » and compares the results of PHPP and BEopt modeling of the project. The design includes high R-Value assemblies, extremely tight construction, high performance doors and windows, solar thermal DHW, heat recovery ventilation, moveable external shutters and a high performance ductless mini-split heat pump. Cost analysis indicates that many of the measures implemented in this project did not meet the BA standard for cost neutrality. The ductless mini-split heat pump, lighting and advanced air leakage control were the most cost effective measures. The future challenge will be to value engineer the performance levels indicated here in modeling using production based practices at a significantly lower cost.« less

  12. New Whole-House Solutions Case Study: Hood River Passive House

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2014-02-01

    The Hood River Passive Project was developed by Root Design Build of Hood River Oregon using the Passive House Planning Package (PHPP) to meet all of the requirements for certification under the European Passive House standards. The Passive House design approach has been gaining momentum among residential designers for custom homes and BEopt modeling indicates that these designs may actually exceed the goal of the U.S. Department of Energy's (DOE) Building America program to "reduce home energy use by 30%-50%" (compared to 2009 energy codes for new homes). This report documents the short term test results of the Shift Housemore » and compares the results of PHPP and BEopt modeling of the project. The design includes high R-Value assemblies, extremely tight construction, high performance doors and windows, solar thermal DHW, heat recovery ventilation, moveable external shutters and a high performance ductless mini-split heat pump. Cost analysis indicates that many of the measures implemented in this project did not meet the BA standard for cost neutrality. The ductless mini-split heat pump, lighting and advanced air leakage control were the most cost effective measures. The future challenge will be to value engineer the performance levels indicated here in modeling using production based practices at a significantly lower cost.« less

  13. Disturbance observer based Takagi-Sugeno fuzzy control for an active seat suspension

    NASA Astrophysics Data System (ADS)

    Ning, Donghong; Sun, Shuaishuai; Zhang, Fei; Du, Haiping; Li, Weihua; Zhang, Bangji

    2017-09-01

    In this paper, a disturbance observer based Takagi-Sugeno (TS) fuzzy controller is proposed for an active seat suspension; both simulations and experiments have been performed verifying the performance enhancement and stability of the proposed controller. The controller incorporates closed-loop feedback control using the measured acceleration of the seat and deflection of the suspension; these two variables can be easily measured in practical applications, thus allowing the proposed controller to be robust and adaptable. A disturbance observer that can estimate the disturbance caused by friction, model simplification, and controller output error has also been used to compensate a H∞ state feedback controller. The TS fuzzy control method is applied to enhance the controller's performance by considering the variation of driver's weight during operation. The vibration of a heavy duty vehicle seat is largest in the frequency range between 2 Hz and 4 Hz, in the vertical direction; therefore, it is reasonable to focus on controlling low frequency vibration amplitudes and maintain the seat suspensions passivity at high frequency. Moreover, both the simulation and experimental results show that the active seat suspension with the proposed controller can effectively isolate unwanted vibration amplitudes below 4.5 Hz, when compared with a well-tuned passive seat suspension. The active controller has been further validated under bump and random road tests with both a 55 kg and a 70 kg loads. The bump road test demonstrated the controller has good transient response capabilities. The random road test result has been presented both in the time domain and the frequency domain. When with the above two loads, the controlled seat suspensions root-mean-square (RMS) accelerations were reduced by 45.5% and 49.5%, respectively, compared with a well-tuned passive seat suspension. The proposed active seat suspension controller has great potential and is very practical for application as it can significantly improve heavy duty driver's ride comfort.

  14. Extended Abstracts, International Society of Electrochemistry (36th) Held at Salamanca, Spain on 23-28 September 1985.

    DTIC Science & Technology

    1985-09-28

    INTERFACE USING HIGH POWER LASER PULSES 07220 R. Kndier IMPEDANCE OF A SODIUMPOLYSULPHIDE ELECTRODE DURING THE PHA- SE TRANSITIOJ MOLTEN/SOLID 723C...life. They are: 1. Corrosion case history evaluation and corrosion control measures 2. Determination of corrosion rates for given corrosion systems 3...theu~ re>M;ivat at ia ia o aae~be orea-o ob-fre ewe h 1.4-2 a high rate reaching passive current densities after several milliseconds. In this passive

  15. A comparison of whole body vibration and moist heat on lower extremity skin temperature and skin blood flow in healthy older individuals.

    PubMed

    Lohman, Everett B; Sackiriyas, Kanikkai Steni Balan; Bains, Gurinder S; Calandra, Giovanni; Lobo, Crystal; Nakhro, Daniel; Malthankar, Gauri; Paul, Sherwine

    2012-07-01

    Tissue healing is an intricate process that is regulated by circulation. Heat modalities have been shown to improve skin circulation. Recent research supports that passive vibration increases circulation without risk of burns. Study purpose is to compare and determine effects of short duration vibration, moist heat, and a combination of the two on skin blood flow (SBF) and skin temperature (ST) in elderly, non-diabetic individuals following short-term exposure. Ten subjects, 3 female and 7 male (55-73 years of age), received two interventions over three days: 1--Active vibration, 2--passive vibration, 3--moist heat, 4--moist heat combined with passive vibration (MHPV), 5--a commercial massaging heating pad, and 6--no intervention. SBF and ST were measured using a MOOR Laser Doppler before and after the intervention and the third measurement were taken 10 minutes following. Mean SBF following a ten-minute intervention were significantly different in the combination of moist heat and passive vibration from the control, active vibration, and the commercial massaging heating pad. Compared to baseline measurements, this resulted in mean SBF elevation to 450% (at conclusion of 10 minutes of intervention) and 379% (10 minutes post). MHPV (p=0.02) showed significant changes in ST from the commercial massaging heating pad, passive vibration, and active vibration interventions. SBF in the lower legs showed greatest increase with MHPV. Interventions should be selected that are low risk while increasing lower extremity skin blood flow.

  16. Uniformity and passivation research of Al2O3 film on silicon substrate prepared by plasma-enhanced atom layer deposition.

    PubMed

    Jia, Endong; Zhou, Chunlan; Wang, Wenjing

    2015-01-01

    Plasma-enhanced atom layer deposition (PEALD) can deposit denser films than those prepared by thermal ALD. But the improvement on thickness uniformity and the decrease of defect density of the films deposited by PEALD need further research. A PEALD process from trimethyl-aluminum (TMA) and oxygen plasma was investigated to study the influence of the conditions with different plasma powers and deposition temperatures on uniformity and growth rate. The thickness and refractive index of films were measured by ellipsometry, and the passivation effect of alumina on n-type silicon before and after annealing was measured by microwave photoconductivity decay method. Also, the effects of deposition temperature and annealing temperature on effective minority carrier lifetime were investigated. Capacitance-voltage and conductance-voltage measurements were used to investigate the interface defect density of state (D it) of Al2O3/Si. Finally, Al diffusion P(+) emitter on n-type silicon was passivated by PEALD Al2O3 films. The conclusion is that the condition of lower substrate temperature accelerates the growth of films and that the condition of lower plasma power controls the films' uniformity. The annealing temperature is higher for samples prepared at lower substrate temperature in order to get the better surface passivation effects. Heavier doping concentration of Al increased passivation quality after annealing by the effective minority carrier lifetime up to 100 μs.

  17. Effect of passive sensitization on the mechanical activity of human isolated bronchial smooth muscle induced by substance P, neurokinin A and VIP.

    PubMed

    Ben-Jebria, A; Marthan, R; Rossetti, M; Savineau, J P

    1993-05-01

    1. The effect of passive sensitization on the mechanical activity of human isolated bronchial smooth muscle induced by the following neuropeptides substance P (SP), neurokinin A (NKA) and vasoactive intestinal peptide (VIP) was studied both in the absence and in the presence of the neutral endopeptidase (NEP) inhibitor, phosphoramidon. 2. Cumulative concentration-response curves (CCRC) to these neuropeptides were constructed in human passively sensitized isolated bronchial rings and compared to those in paired controls. Passively sensitized human isolated bronchial rings were tissues incubated overnight in serum from asthmatic patients atopic to Dermatophagoides pteronyssinus and paired controls were tissues originating from the same lung specimens but incubated overnight in serum from healthy donors. 3. In the absence of phosphoramidon, passive sensitization significantly increased the amplitude of the contractile responses to SP and NKA including that to the maximal concentration given from 50 +/- 5% to 76 +/- 6% (n = 5, P < 0.05) and from 70 +/- 7% to 101 +/- 6% (n = 5, P < 0.05) of the maximal response to acetylcholine, respectively. Passive sensitization significantly shifted to the left the CCRC for both tachykinins as measured by the geometric means dose-ratios which were 8.5 (95% confidence limits (CL): 3.1-13.9) and 7.3 (95% CL: 4.2-10.3) for SP and NKA, respectively. 4. In the presence of phosphoramidon (10 microM), passive sensitization still increased significantly the amplitude of the contractile responses to SP and NKA including that to the maximal concentration given from 74 +/- 4% to 115 +/- 7% (n = 5, P<0.05) and from 104 +/- 9% to 146 +/- 16% (n = 5, P<0.05)of the maximal response to acetylcholine, respectively. Passive sensitization still significantly shifted to the left the CCRC for both tachykinins as measured by the dose-ratios which were 9.0 (95% CL:4.3-13.6) and 5.4 (95% CL: 2.9-7.9) for SP and NKA, respectively.5. The relaxant response to the maximal concentration of VIP given in tissues precontracted with histamine (0.5 mM) was significantly reduced by passive sensitization from 41 +/- 4% to 25 +/- 3% (n = 5,P <0.05) of the amplitude of the precontraction in the absence of phosphoramidon and from 72 +/- 1%to 49 +/- 4% (n = 5, P<0.05) in the presence of phosphoramidon (10 microM). Passive sensitization significantly shifted to the right the CCRC for VIP as measured by the dose-ratios which were 10.4(95% CL: 6.6-14.1) and 6.4 (95% CL: 3.0-9.8) in the absence and in the presence of phosphoramidon,respectively.6. We conclude that passive sensitization enhances the mechanical response to neuropeptides which contract human isolated bronchial smooth muscle and reduces that to a neuropeptide which relaxes it.The mechanism of passive sensitization-induced changes in the mechanical activity appears to be independent of a decrease in NEP activity since these changes persist in the presence of the NEP inhibitor, phosphoramidon.

  18. Synthesis Methods for Robust Passification and Control

    NASA Technical Reports Server (NTRS)

    Kelkar, Atul G.; Joshi, Suresh M. (Technical Monitor)

    2000-01-01

    The research effort under this cooperative agreement has been essentially the continuation of the work from previous grants. The ongoing work has primarily focused on developing passivity-based control techniques for Linear Time-Invariant (LTI) systems. During this period, there has been a significant progress made in the area of passivity-based control of LTI systems and some preliminary results have also been obtained for nonlinear systems, as well. The prior work has addressed optimal control design for inherently passive as well as non- passive linear systems. For exploiting the robustness characteristics of passivity-based controllers the passification methodology was developed for LTI systems that are not inherently passive. Various methods of passification were first proposed in and further developed. The robustness of passification was addressed for multi-input multi-output (MIMO) systems for certain classes of uncertainties using frequency-domain methods. For MIMO systems, a state-space approach using Linear Matrix Inequality (LMI)-based formulation was presented, for passification of non-passive LTI systems. An LMI-based robust passification technique was presented for systems with redundant actuators and sensors. The redundancy in actuators and sensors was used effectively for robust passification using the LMI formulation. The passification was designed to be robust to an interval-type uncertainties in system parameters. The passification techniques were used to design a robust controller for Benchmark Active Control Technology wing under parametric uncertainties. The results on passive nonlinear systems, however, are very limited to date. Our recent work in this area was presented, wherein some stability results were obtained for passive nonlinear systems that are affine in control.

  19. Goal setting, using goal attainment scaling, as a method to identify patient selected items for measuring arm function.

    PubMed

    Ashford, Stephen; Jackson, Diana; Turner-Stokes, Lynne

    2015-03-01

    Following stroke or brain injury, goals for rehabilitation of the hemiparetic upper limb include restoring active function if there is return of motor control or, if none is possible, improving passive function, and facilitating care for the limb. To inform development of a new patient reported outcome measure (PROM) of active and passive function in the hemiparetic upper limb, the Arm Activity measure, we examined functional goals for the upper limb, identified during goal setting for spasticity intervention (physical therapy and concomitant botulinum toxin A interventions). Using secondary analysis of a prospective observational cohort study, functional goals determined between patients, their carers and the clinical team were assigned into categories by two raters. Goal category identification, followed by assignment of goals to a category, was undertaken and then confirmed by a second reviewer. Participants comprised nine males and seven females of mean (SD) age 54.5 (15.7) years and their carers. Fifteen had sustained a stroke and one a traumatic brain injury. Goals were used to identify five categories: passive function, active function, symptoms, cosmesis and impairment. Two passive function items not previously identified by a previous systematic review were identified. Analysis of goals important to patients and carers revealed items for inclusion in a new measure of arm function and provide a useful alternative method to involve patients and carers in standardised measure development. Copyright © 2014 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  20. A Passive Cavity Concept for Improving the Off-Design Performance of Fixed-Geometry Exhaust Nozzles

    NASA Technical Reports Server (NTRS)

    Asbury, Scott C.; Gunther, Christopher L.; Hunter, Craig A.

    1996-01-01

    An investigation was conducted in the model preparation area of the Langley 16-Foot Transonic Tunnel to study a passive cavity concept for improving the off-design performance of fixed-geometry exhaust nozzles. Passive cavity ventilation (through a porous surface) was applied to divergent flap surfaces and tested at static conditions in a sub-scale, nonaxisymmetric, convergent-divergent nozzle. As part of a comprehensive investigation, force, moment and pressure measurements were taken and focusing schlieren flow visualization was obtained for a baseline configuration and D passive cavity configurations. All tests were conducted with no external flow and high-pressure air was used to simulate jet-exhaust flow at nozzle pressure ratios from 1.25 to approximately 9.50. Results indicate that baseline nozzle performance was dominated by unstable shock-induced boundary-layer separation at off-design conditions, which came about through the natural tendency of overexpanded exhaust flow to satisfy conservation requirements by detaching from the nozzle divergent flaps. Passive cavity ventilation added the ability to control off-design separation in the nozzle by either alleviating separation or encouraging stable separation of the exhaust flow. Separation alleviation offers potential for installed nozzle performance benefits by reducing drag at forward flight speeds, even though it may reduce off-design static thrust efficiency as much as 3.2 percent. Encouraging stable separation of the exhaust flow offers significant performance improvements at static, low NPR and low Mach number flight conditions by improving off-design static thrust efficiency as much as 2.8 percent. By designing a fixed-geometry nozzle with fully porous divergent flaps, where both cavity location and percent open porosity of the flaps could be varied, passive flow control would make it possible to improve off-design nozzle performance across a wide operating range. In addition, the ability to encourage separation on one flap while alleviating it on the other makes it possible to generate thrust vectoring in the nozzle through passive flow control.

  1. Passivity and Dissipativity as Design and Analysis Tools for Networked Control Systems

    ERIC Educational Resources Information Center

    Yu, Han

    2012-01-01

    In this dissertation, several control problems are studied that arise when passive or dissipative systems are interconnected and controlled over a communication network. Since communication networks can impact the systems' stability and performance, there is a need to extend the results on control of passive or dissipative systems to networked…

  2. Reactive Flow Control of Delta Wing Vortex (Postprint)

    DTIC Science & Technology

    2006-08-01

    wing aircraft. A substantial amount of research has been dedicated to the control of aerodynamic flows using both passive and active control mechanisms...Passive vortex control devices such as vortex generators and winglets attach to the wing and require no energy input. Passive vortex control...leading edges is also effective for changing the aerodynamic characteristics of delta wings [2] [3]. Gutmark and Guillot [5] proposed controlling

  3. Integrated passive/active vibration absorber for multi-story buildings

    NASA Technical Reports Server (NTRS)

    Lee-Glauser, Gina J.; Ahmadi, Goodarz; Horta, Lucas G.

    1995-01-01

    Passive isolator, active vibration absorber, and an integrated passive/active (hybrid) control are studied for their effectiveness in reducing structural vibration under seismic excitations. For the passive isolator, a laminated rubber bearing base isolator which has been studied and used extensively by researchers and seismic designers is considered. An active vibration absorber concept, which can provide guaranteed closed-loop stability with minimum knowledge of the controlled system, is used to reduce the passive isolator displacement and to suppress the top floor vibration. A three-story building model is used for the numerical simulation. The performance of an active vibration absorber and a hybrid vibration controller in reducing peak structural responses is compared with the passively isolated structural response and with absence of vibration control systems under the N00W component of El Centro 1940 and N90W component of the Mexico City earthquake excitation records. The results show that the integrated passive/active vibration control system is most effective in suppressing the peak structural acceleration for the El Centro 1940 earthquake when compared with the passive or active vibration absorber alone. The active vibration absorber, however, is the only system that suppresses the peak acceleration of the structure for the Mexico City 1985 earthquake.

  4. Efficacy of sonic and ultrasonic activation for removal of calcium hydroxide from mesial canals of mandibular molars: a microtomographic study.

    PubMed

    Wiseman, Anne; Cox, Timothy C; Paranjpe, Avina; Flake, Natasha M; Cohenca, Nestor; Johnson, James D

    2011-02-01

    The purpose of this study was to use micro-computed tomography (micro-CT) scanning to evaluate the efficacy of sonic and passive ultrasonic irrigation (PUI) on calcium hydroxide (Ca[OH](2)) removal and to measure the volume and percentage of Ca(OH)(2) remaining in the root canal system. The root canals of 46 extracted human mandibular molar teeth were prepared with rotary instruments and randomly assigned to two experimental groups (n = 40) as well as positive and negative controls (n = 6). In each experimental group, 20 teeth were assigned to each irrigation protocol, sonic or passive ultrasonic irrigation. All experimental teeth and the positive controls were filled with Ca(OH)(2), whereas the negative control teeth did not receive Ca(OH)(2). All teeth were scanned using micro-CT scanning to determine the dressing volume. After 7 days, the Ca(OH)(2) was removed in the experimental groups using rotary instrumentation only, and the teeth were again scanned using micro-CT scanning to calculate volume and percentage of Ca(OH)(2) removed. Positive control teeth were not subjected to rotary instrumentation. Experimental samples were then irrigated using either sonic or passive ultrasonic and the volume of remaining Ca(OH)(2) was calculated using micro-CT. Remnants of Ca(OH)(2) were found in all experimental groups. No Ca(OH)(2) was found in the negative controls, whereas a mean of 8.7 mm(3) of Ca(OH)(2) was recorded in the positive controls. Rotary plus passive ultrasonic irrigation removed significantly more Ca(OH)(2) (85.7%) than rotary plus sonic irrigation (71.5%) (p < 0.001). The combination of rotary instrumentation and passive ultrasonic activation for 3 periods of 20 seconds results in significantly lower amounts of Ca(OH)(2) remnants in the canal compared with sonic irrigation. Copyright © 2011. Published by Elsevier Inc.

  5. The Planned Soil Moisture Active Passive (SMAP) Mission L-Band Radar/Radiometer Instrument

    NASA Technical Reports Server (NTRS)

    Spencer, Michael; Wheeler, Kevin; Chan, Samuel; Piepmeier, Jeffrey; Hudson, Derek; Medeiros, James

    2011-01-01

    The Soil Moisture Active/Passive (SMAP) mission is a NASA mission identified by the NRC 'decadal survey' to measure both soil moisture and freeze/thaw state from space. The mission will use both active radar and passive radiometer instruments at L-Band. In order to achieve a wide swath at sufficiently high resolution for both active and passive channels, an instrument architecture that uses a large rotating reflector is employed. The instrument system has completed the preliminary design review (PDR) stage, and detailed instrument design has begun. In addition to providing an overview of the instrument design, two recent design modifications are discussed: 1) The addition of active thermal control to the instrument spun side to provide a more stable, settable thermal environment for the radiometer electronics, and 2) A 'sequential transmit' strategy for the two radar polarization channels which allows a single high-power amplifier to be used.

  6. Anodized aluminum on LDEF: A current status of measurements on chromic acid anodized aluminum

    NASA Technical Reports Server (NTRS)

    Golden, Johnny L.

    1992-01-01

    Chromic acid anodize was used as the exterior coating for aluminum surfaces on LDEF to provide passive thermal control. Chromic acid anodized aluminum was also used as test specimens in thermal control coatings experiments. The following is a compilation and analysis of the data obtained thus far.

  7. Evaluation of a passive method for determining particle penetration through protective clothing materials.

    PubMed

    Jaques, Peter A; Portnoff, Lee

    2017-12-01

    The risk of workers' exposure to aerosolized particles has increased with the upsurge in the production of engineered nanomaterials. Currently, a whole-body standard test method for measuring particle penetration through protective clothing ensembles is not available. Those available for respirators neglect the most common challenges to ensembles, because they use active vacuum-based filtration, designed to simulate breathing, rather than the positive forces of wind experienced by workers. Thus, a passive method that measures wind-driven particle penetration through ensemble fabric has been developed and evaluated. The apparatus includes a multidomain magnetic passive aerosol sampler housed in a shrouded penetration cell. Performance evaluation was conducted in a recirculation aerosol wind tunnel using paramagnetic Fe 3 O 4 (i.e., iron (II, III) oxide) particles for the challenge aerosol. The particles were collected on a PVC substrate and quantified using a computer-controlled scanning electron microscope. Particle penetration levels were determined by taking the ratio of the particle number collected on the substrate with a fabric (sample) to that without a fabric (control). Results for each fabric obtained by this passive method were compared to previous results from an automated vacuum-based active fractional efficiency tester (TSI 3160), which used sodium chloride particles as the challenge aerosol. Four nonwoven fabrics with a range of thicknesses, porosities, and air permeabilities were evaluated. Smoke tests and flow modeling showed the passive sampler shroud provided smooth (non-turbulent) air flow along the exterior of the sampler, such that disturbance of flow stream lines and distortion of the particle size distribution were reduced. Differences between the active and passive approaches were as high as 5.5-fold for the fabric with the lowest air permeability (0.00067 m/sec-Pa), suggesting the active method overestimated penetration in dense fabrics because the active method draws air at a constant flow rate regardless of the resistance of the test fabric. The passive method indicated greater sensitivity since penetration decreased in response to the increase in permeability.

  8. Effectiveness analyses may underestimate protection of infants after group C meningococcal immunization.

    PubMed

    Vu, David M; Kelly, Dominic; Heath, Paul T; McCarthy, Noel D; Pollard, Andrew J; Granoff, Dan M

    2006-07-15

    Group C meningococcal conjugate-vaccine effectiveness in the United Kingdom declines from ~90% in the first year to 0% between 1 and 4 years after immunization in infants immunized at 2, 3, and 4 months of age and to 61% in toddlers given a single dose. Confidence intervals are wide, and the extent of protection is uncertain. Serum samples were obtained from children 3-5 years of age who were participants in a preschool booster-vaccine trial. Serum bactericidal activity was measured with human complement. Group C anticapsular antibody concentrations were measured by a radioantigen binding assay. Passive protection was analyzed in an infant rat bacteremia model. Serum samples from UK children who had been immunized 2-3 years earlier as infants or toddlers had higher levels of radioantigen binding, bactericidal activity, and passive protection than did historical control serum samples from unimmunized children (P<.05). A higher proportion of children immunized as infants had serum bactericidal activity titers > or =1 : 4 (considered to be protective) than those immunized as toddlers (61% vs. 24%; P<.01), but there were no significant differences in the proportion of serum samples conferring passive protection (50% and 41%, respectively; P=.4). We found no evidence of lower immunity in children immunized as infants than as toddlers. On the basis of serum bactericidal activity and/or passive protection, 40%-50% of both age groups are protected at 2-3 years after immunization, which was significantly greater than in unimmunized historical controls (<5%).

  9. A passivity criterion for sampled-data bilateral teleoperation systems.

    PubMed

    Jazayeri, Ali; Tavakoli, Mahdi

    2013-01-01

    A teleoperation system consists of a teleoperator, a human operator, and a remote environment. Conditions involving system and controller parameters that ensure the teleoperator passivity can serve as control design guidelines to attain maximum teleoperation transparency while maintaining system stability. In this paper, sufficient conditions for teleoperator passivity are derived for when position error-based controllers are implemented in discrete-time. This new analysis is necessary because discretization causes energy leaks and does not necessarily preserve the passivity of the system. The proposed criterion for sampled-data teleoperator passivity imposes lower bounds on the teleoperator's robots dampings, an upper bound on the sampling time, and bounds on the control gains. The criterion is verified through simulations and experiments.

  10. Incremental passivity and output regulation for switched nonlinear systems

    NASA Astrophysics Data System (ADS)

    Pang, Hongbo; Zhao, Jun

    2017-10-01

    This paper studies incremental passivity and global output regulation for switched nonlinear systems, whose subsystems are not required to be incrementally passive. A concept of incremental passivity for switched systems is put forward. First, a switched system is rendered incrementally passive by the design of a state-dependent switching law. Second, the feedback incremental passification is achieved by the design of a state-dependent switching law and a set of state feedback controllers. Finally, we show that once the incremental passivity for switched nonlinear systems is assured, the output regulation problem is solved by the design of global nonlinear regulator controllers comprising two components: the steady-state control and the linear output feedback stabilising controllers, even though the problem for none of subsystems is solvable. Two examples are presented to illustrate the effectiveness of the proposed approach.

  11. Muscle sympathetic nerve responses to passive and active one-legged cycling: insights into the contributions of central command.

    PubMed

    Doherty, Connor J; Incognito, Anthony V; Notay, Karambir; Burns, Matthew J; Slysz, Joshua T; Seed, Jeremy D; Nardone, Massimo; Burr, Jamie F; Millar, Philip J

    2018-01-01

    The contribution of central command to the peripheral vasoconstrictor response during exercise has been investigated using primarily handgrip exercise. The purpose of the present study was to compare muscle sympathetic nerve activity (MSNA) responses during passive (involuntary) and active (voluntary) zero-load cycling to gain insights into the effects of central command on sympathetic outflow during dynamic exercise. Hemodynamic measurements and contralateral leg MSNA (microneurography) data were collected in 18 young healthy participants at rest and during 2 min of passive and active zero-load one-legged cycling. Arterial baroreflex control of MSNA burst occurrence and burst area were calculated separately in the time domain. Blood pressure and stroke volume increased during exercise ( P < 0.0001) but were not different between passive and active cycling ( P > 0.05). In contrast, heart rate, cardiac output, and total vascular conductance were greater during the first and second minute of active cycling ( P < 0.001). MSNA burst frequency and incidence decreased during passive and active cycling ( P < 0.0001), but no differences were detected between exercise modes ( P > 0.05). Reductions in total MSNA were attenuated during the first ( P < 0.0001) and second ( P = 0.0004) minute of active compared with passive cycling, in concert with increased MSNA burst amplitude ( P = 0.02 and P = 0.005, respectively). The sensitivity of arterial baroreflex control of MSNA burst occurrence was lower during active than passive cycling ( P = 0.01), while control of MSNA burst strength was unchanged ( P > 0.05). These results suggest that central feedforward mechanisms are involved primarily in modulating the strength, but not the occurrence, of a sympathetic burst during low-intensity dynamic leg exercise. NEW & NOTEWORTHY Muscle sympathetic nerve activity burst frequency decreased equally during passive and active cycling, but reductions in total muscle sympathetic nerve activity were attenuated during active cycling. These results suggest that central command primarily regulates the strength, not the occurrence, of a muscle sympathetic burst during low-intensity dynamic leg exercise.

  12. Hysteresis in the Active Oxidation of SiC

    NASA Technical Reports Server (NTRS)

    Jacobson, Nathan S.; Harder, Bryan J.; Myers, Dwight L.

    2011-01-01

    Si and SiC show both passive oxidation behavior where a protective film of SiO2 forms and active oxidation behavior where a volatile suboxide SiO(g) forms. The active-to-passive and passive-to-active oxidation transitions are explored for both Si and SiC. Si shows a dramatic difference between the P(O2) for the two transitions of 10-4 bar. The active-to-passive transition is controlled by the condition for SiO2/Si equilibrium and the passive-to-active transition is controlled by the decomposition of SiO2. In the case of SiC, the P(O2) for these transitions are much closer. The active-to-passive transition appears to be controlled by the condition for SiO2/SiC equilibrium. The passive-to-active transition appears to be controlled by the interfacial reaction of SiC and SiO2 and subsequent generation of gases at the interface which leads to scale breakdown.

  13. Passive and Active Control of Space Structures (PACOSS)

    NASA Astrophysics Data System (ADS)

    Morosow, G.; Harcrow, H.; Rogers, L.

    1985-04-01

    Passive and Active Control of Space Structures (PACOSS) is a five-year program designed to investigate highly damped structures in conjunction with active control systems, and in particular to develop technology that integrates passive damping and active control to achieve precise pointing control. Major areas of research include metal matrix composites; viscoelastic materials; damping devices; dynamic test article design, fabrication and testing; and active damping.

  14. Commissioning a passive-scattering proton therapy nozzle for accurate SOBP delivery.

    PubMed

    Engelsman, M; Lu, H M; Herrup, D; Bussiere, M; Kooy, H M

    2009-06-01

    Proton radiotherapy centers that currently use passively scattered proton beams do field specific calibrations for a non-negligible fraction of treatment fields, which is time and resource consuming. Our improved understanding of the passive scattering mode of the IBA universal nozzle, especially of the current modulation function, allowed us to re-commission our treatment control system for accurate delivery of SOBPs of any range and modulation, and to predict the output for each of these fields. We moved away from individual field calibrations to a state where continued quality assurance of SOBP field delivery is ensured by limited system-wide measurements that only require one hour per week. This manuscript reports on a protocol for generation of desired SOBPs and prediction of dose output.

  15. Poststroke agitation and aggression and social quality of life: a case control study.

    PubMed

    Lau, Chieh Grace; Tang, Wai Kwong; Liu, Xiang Xin; Liang, Hua Jun; Liang, Yan; Wong, Adrian; Mok, Vincent; Ungvari, Gabor S; Wong, Ka Sing; Kim, Jong S; Paradiso, Sergio

    2017-03-01

    Aggression and agitation are common after a stroke. The association between agitation/aggression following stroke and Health-Related Quality of Life (HRQoL) in stroke survivors is unknown. This study aimed to examine the association between agitation/aggression and HRQoL in Chinese stroke survivors. Three hundred and twenty-four stroke patients entered this cross-sectional study. Agitation/aggression was assessed using the Chinese version of Neuropsychiatric Inventory (CNPI). HRQoL was measured with the Stroke Specific Quality of Life (SSQoL). Three months after the index stroke, agitation/aggression was found in 60 (18.5%) patients. In the agitation/aggression group, 44 patients (73.3%) showed passive agitation/aggression, whereas 16 (26.7%) displayed passive and active agitation/aggression. No patients showed only active agitation/aggression. Patients with agitation/aggression were more likely to have history of diabetes and greater severity of depression, as well as lower SSQoL total score and Personality Changes and Social Role scores. Controlling for diabetes and depression severity did not alter the above results. The Energy and Thinking scores of the SSQoL were significantly lower in the passive/active agitation/aggression group relative to the passive agitation/aggression group (adjusted for CNPI aggression/agitation score). In this study sample, agitation/aggression was preponderantly of the passive type and was associated with poorer HRQoL independently from depression or medical conditions. Patients with both passive and active agitation/aggression had lower Quality of Life (QoL) than patients with only passive agitation/aggression. The causality of the association between low QoL and agitation/aggression needs to be explored in future studies.

  16. Boundary Layer Control for Hypersonic Airbreathing Vehicles

    NASA Technical Reports Server (NTRS)

    Berry, Scott A.; Nowak, Robert J.; Horvath, Thomas J.

    2004-01-01

    Active and passive methods for tripping hypersonic boundary layers have been examined in NASA Langley Research Center wind tunnels using a Hyper-X model. This investigation assessed several concepts for forcing transition, including passive discrete roughness elements and active mass addition (or blowing), in the 20-Inch Mach 6 Air and the 31-Inch Mach 10 Air Tunnels. Heat transfer distributions obtained via phosphor thermography, shock system details, and surface streamline patterns were measured on a 0.333-scale model of the Hyper-X forebody. The comparisons between the active and passive methods for boundary layer control were conducted at test conditions that nearly match the Hyper-X nominal Mach 7 flight test-point of an angle-of-attack of 2-deg and length Reynolds number of 5.6 million. For passive roughness, the primary parametric variation was a range of trip heights within the calculated boundary layer thickness for several trip concepts. The passive roughness study resulted in a swept ramp configuration, scaled to be roughly 0.6 of the calculated boundary layer thickness, being selected for the Mach 7 flight vehicle. For the active blowing study, the manifold pressure was systematically varied (while monitoring the mass flow) for each configuration to determine the jet penetration height, with schlieren, and transition movement, with the phosphor system, for comparison to the passive results. All the blowing concepts tested, which included various rows of sonic orifices (holes), two- and three-dimensional slots, and random porosity, provided transition onset near the trip location with manifold stagnation pressures on the order of 40 times the model surface static pressure, which is adequate to ensure sonic jets. The present results indicate that the jet penetration height for blowing was roughly half the height required with passive roughness elements for an equivalent amount of transition movement.

  17. Potential Relationship between Passive Plantar Flexor Stiffness and Running Performance.

    PubMed

    Ueno, Hiromasa; Suga, Tadashi; Takao, Kenji; Tanaka, Takahiro; Misaki, Jun; Miyake, Yuto; Nagano, Akinori; Isaka, Tadao

    2018-02-01

    The present study aimed to determine the relationship between passive stiffness of the plantar flexors and running performance in endurance runners. Forty-eight well-trained male endurance runners and 24 untrained male control subjects participated in this study. Plantar flexor stiffness during passive dorsiflexion was calculated from the slope of the linear portion of the torque-angle curve. Of the endurance runners included in the present study, running economy in 28 endurance runners was evaluated by measuring energy cost during three 4-min trials (14, 16, and 18 km/h) of submaximal treadmill running. Passive stiffness of the plantar flexors was significantly higher in endurance runners than in untrained subjects. Moreover, passive plantar flexor stiffness in endurance runners was significantly correlated with a personal best 5000-m race time. Furthermore, passive plantar flexor stiffness in endurance runners was significantly correlated with energy cost during submaximal running at 16 km/h and 18 km/h, and a trend towards such significance was observed at 14 km/h. The present findings suggest that stiffer plantar flexors may help achieve better running performance, with greater running economy, in endurance runners. Therefore, in the clinical setting, passive stiffness of the plantar flexors may be a potential parameter for assessing running performance. © Georg Thieme Verlag KG Stuttgart · New York.

  18. Changes in passive tactile sensibility associated with dental implants following their placement.

    PubMed

    El-Sheikh, Ali M; Hobkirk, John A; Howell, Peter G T; Gilthorpe, Mark S

    2003-01-01

    This study investigated the changes that might occur in passive tactile sensibility during a period of 3 months following Implant placement in a group of edentulous subjects treated with dental implants. The effect of changing the velocity of force application on passive tactile sensibility was also investigated. Five edentulous subjects who had been treated (as a part of an immediate loading study) with 2 or more Nobel Biocare dental implants in the anterior mandible were studied. Pushing forces were applied directly and perpendicular to the long axes of the abutments until the subjects felt the first sensation of pressure, using a computer-controlled, custom-made device. The force was measured with an integral transducer. The applied force had a ramped staircase pattern, which was used at 2 different tip velocities. The measurements were taken on 4 occasions: 1, 2, 4, and 12 weeks after fitting the abutments. Statistical analysis, using multilevel modeling, demonstrated that there was a significant decrease In the tactile threshold over successive weeks following implant placement. It also demonstrated that high velocity exhibited a higher threshold than low velocity. It could be concluded that there was a significant increase In passive tactile sensibility during the healing phase following implant placement.

  19. Measurement of the passive fast-ion D-alpha emission on the NSTX-U tokamak

    DOE PAGES

    Hao, G. Z.; Heidbrink, W. W.; Liu, D.; ...

    2018-01-08

    On National Spherical Torus Experiment Upgrade, the passive fast-ion D-alpha (passive-FIDA) spectra from charge exchange (CX) between the beam ions and the background neutrals are measured and simulated. The results indicate that the passive-FIDA signal is measurable and comparable to the active-FIDA on several channels, such as at the major radius R = 117 cm. For this, active-FIDA means the active D-alpha emission from the fast ions that CX with the injected neutrals. The shapes of measured spectra are in agreement with FIDASIM simulations on many fibers. Furthermore, the passive-FIDA spatial profile agrees with the simulation. When making measurements ofmore » active-FIDA in the edge region using time-slice subtraction, variations in the passive-FIDA contribution to the signal should be considered.« less

  20. Measurement of the passive fast-ion D-alpha emission on the NSTX-U tokamak

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hao, G. Z.; Heidbrink, W. W.; Liu, D.

    On National Spherical Torus Experiment Upgrade, the passive fast-ion D-alpha (passive-FIDA) spectra from charge exchange (CX) between the beam ions and the background neutrals are measured and simulated. The results indicate that the passive-FIDA signal is measurable and comparable to the active-FIDA on several channels, such as at the major radius R = 117 cm. For this, active-FIDA means the active D-alpha emission from the fast ions that CX with the injected neutrals. The shapes of measured spectra are in agreement with FIDASIM simulations on many fibers. Furthermore, the passive-FIDA spatial profile agrees with the simulation. When making measurements ofmore » active-FIDA in the edge region using time-slice subtraction, variations in the passive-FIDA contribution to the signal should be considered.« less

  1. Experiments on integral length scale control in atmospheric boundary layer wind tunnel

    NASA Astrophysics Data System (ADS)

    Varshney, Kapil; Poddar, Kamal

    2011-11-01

    Accurate predictions of turbulent characteristics in the atmospheric boundary layer (ABL) depends on understanding the effects of surface roughness on the spatial distribution of velocity, turbulence intensity, and turbulence length scales. Simulation of the ABL characteristics have been performed in a short test section length wind tunnel to determine the appropriate length scale factor for modeling, which ensures correct aeroelastic behavior of structural models for non-aerodynamic applications. The ABL characteristics have been simulated by using various configurations of passive devices such as vortex generators, air barriers, and slot in the test section floor which was extended into the contraction cone. Mean velocity and velocity fluctuations have been measured using a hot-wire anemometry system. Mean velocity, turbulence intensity, turbulence scale, and power spectral density of velocity fluctuations have been obtained from the experiments for various configuration of the passive devices. It is shown that the integral length scale factor can be controlled using various combinations of the passive devices.

  2. Passive wick fluxmeters: Design considerations and field applications

    NASA Astrophysics Data System (ADS)

    Gee, G. W.; Newman, B. D.; Green, S. R.; Meissner, R.; Rupp, H.; Zhang, Z. F.; Keller, J. M.; Waugh, W. J.; van der Velde, M.; Salazar, J.

    2009-04-01

    Optimization of water use in agriculture and quantification of percolation from landfills and watersheds require reliable estimates of vadose zone water fluxes. Current technology is limited primarily to lysimeters, which directly measure water flux but are expensive and may in some way disrupt flow, causing errors in the measured drainage. We report on design considerations and field tests of an alternative approach, passive wick fluxmeters, which use a control tube to minimize convergent or divergent flow. Design calculations with a quasi-three-dimensional model illustrate how convergence and divergence can be minimized for a range of soil and climatic conditions under steady state and transient fluxes using control tubes of varying heights. There exists a critical recharge rate for a given wick length, where the fluxmeter collection efficiency is 100% regardless of the height of the control tube. Otherwise, convergent or divergent flow will occur, especially when the control tube height is small. While divergence is eliminated in coarse soils using control tubes, it is reduced but not eliminated in finer soils, particularly for fluxes <100 mm/a. Passive wick fluxmeters were tested in soils ranging from nonvegetated semiarid settings in the United States to grasslands in Germany and rain-fed crops in New Zealand and the South Pacific. Where side-by-side comparisons of drainage were made between passive wick fluxmeters and conventional lysimeters in the United States and Germany, agreement was very good. In semiarid settings, drainage was found to depend upon precipitation distribution, surface soil, topographic relief, and the type and amount of vegetation. In Washington State, United States, soil texture dominated all factors controlling drainage from test landfill covers. As expected, drainage was greatest (>60% annual precipitation) from gravel surfaces and least (no drainage) from silt loam soils. In Oregon and New Mexico, United States, and in New Zealand, drainage showed substantial spatial variability. The New Mexico tests were located in semiarid canyon bottom terraces, with flash flood prone locations having extremely high drainage/precipitation ratios. In the wettest environments, drainage was found to be closely linked to the rate and duration of precipitation events.

  3. Passivity-based control with collision avoidance for a hub-beam spacecraft

    NASA Astrophysics Data System (ADS)

    Wen, Hao; Chen, Ti; Jin, Dongping; Hu, Haiyan

    2017-01-01

    For the application of robotically assembling large space structures, a feedback control law is synthesized for transitional and rotational maneuvers of a 'tug' spacecraft in order to transport a flexible element to a desired position without colliding with other space bodies. The flexible element is treated as a long beam clamped to the 'tug' spacecraft modelled as a rigid hub. First, the physical property of passivity of Euler-Lagrange system is exploited to design the position and attitude controllers by taking a simpler obstacle-free control problem into account. To reduce sensing and actuating requirements, the vibration modes of the beam appendage are supposed to be not directly measured and actuated on. Besides, the requirements of measuring velocities are removed with the aid of a dynamic extension technique. Second, the bounding boxes in the form of super-quadric surfaces are exploited to enclose the maximal extents of the obstacles and the hub-beam spacecraft. The collision avoidance between bounding boxes is achieved by applying additional repulsive force and torque to the spacecraft based on the method of artificial potential field. Finally, the effectiveness of proposed control scheme is numerically demonstrated via case studies.

  4. A comparison of whole body vibration and moist heat on lower extremity skin temperature and skin blood flow in healthy older individuals

    PubMed Central

    Lohman, Everett B.; Sackiriyas, Kanikkai Steni Balan; Bains, Gurinder S.; Calandra, Giovanni; Lobo, Crystal; Nakhro, Daniel; Malthankar, Gauri; Paul, Sherwine

    2012-01-01

    Summary Background Tissue healing is an intricate process that is regulated by circulation. Heat modalities have been shown to improve skin circulation. Recent research supports that passive vibration increases circulation without risk of burns. Study purpose is to compare and determine effects of short duration vibration, moist heat, and a combination of the two on skin blood flow (SBF) and skin temperature (ST) in elderly, non-diabetic individuals following short-term exposure. Material/Methods Ten subjects, 3 female and 7 male (55–73 years of age), received two interventions over three days: 1 – Active vibration, 2 – passive vibration, 3 – moist heat, 4 – moist heat combined with passive vibration (MHPV), 5 – a commercial massaging heating pad, and 6 – no intervention. SBF and ST were measured using a MOOR Laser Doppler before and after the intervention and the third measurement were taken 10 minutes following. Results Mean SBF following a ten-minute intervention were significantly different in the combination of moist heat and passive vibration from the control, active vibration, and the commercial massaging heating pad. Compared to baseline measurements, this resulted in mean SBF elevation to 450% (at conclusion of 10 minutes of intervention) and 379% (10 minutes post). MHPV (p=0.02) showed significant changes in ST from the commercial massaging heating pad, passive vibration, and active vibration interventions. Conclusions SBF in the lower legs showed greatest increase with MHPV. Interventions should be selected that are low risk while increasing lower extremity skin blood flow. PMID:22739731

  5. A new passive radon-thoron discriminative measurement system.

    PubMed

    Sciocchetti, G; Sciocchetti, A; Giovannoli, P; DeFelice, P; Cardellini, F; Cotellessa, G; Pagliari, M

    2010-10-01

    A new passive radon-thoron discriminative measurement system has been developed for monitoring radon and thoron individually. It consists of a 'couple' of passive integrating devices with a CR39 nuclear track detector (NTD). The experimental prototype is based on the application of a new concept of NTD instrument developed at ENEA, named Alpha-PREM, acronym of piston radon exposure meter, which allows controlling the detector exposure with a patented sampling technique (Int. Eu. Pat. and US Pat.). The 'twin diffusion chambers system' was based on two A-PREM devices consisting of the standard device, named NTD-Rn, and a modified version, named NTD-Rn/Tn, which was set up to improve thoron sampling efficiency of the diffusion chamber, without changing the geometry and the start/stop function of the NTD-Rn device. Coupling devices fitted on each device allowed getting a system, which works as a double-chamber structure when deployed at the monitoring position. In this paper both technical and physical aspects are considered.

  6. Equilibrium Passive Sampling of POP in Lipid-Rich and Lean Fish Tissue: Quality Control Using Performance Reference Compounds.

    PubMed

    Rusina, Tatsiana P; Carlsson, Pernilla; Vrana, Branislav; Smedes, Foppe

    2017-10-03

    Passive sampling is widely used to measure levels of contaminants in various environmental matrices, including fish tissue. Equilibrium passive sampling (EPS) of persistent organic pollutants (POP) in fish tissue has been hitherto limited to application in lipid-rich tissue. We tested several exposure methods to extend EPS applicability to lean tissue. Thin-film polydimethylsiloxane (PDMS) passive samplers were exposed statically to intact fillet and fish homogenate and dynamically by rolling with cut fillet cubes. The release of performance reference compounds (PRC) dosed to passive samplers prior to exposure was used to monitor the exchange process. The sampler-tissue exchange was isotropic, and PRC were shown to be good indicators of sampler-tissue equilibration status. The dynamic exposures demonstrated equilibrium attainment in less than 2 days for all three tested fish species, including lean fish containing 1% lipid. Lipid-based concentrations derived from EPS were in good agreement with lipid-normalized concentrations obtained using conventional solvent extraction. The developed in-tissue EPS method is robust and has potential for application in chemical monitoring of biota and bioaccumulation studies.

  7. Brief Report: Compliance and Noncompliance to Parental Control Strategies in Children with High-Functioning Autism and Their Typical Peers

    ERIC Educational Resources Information Center

    Bryce, Crystal I.; Jahromi, Laudan B.

    2013-01-01

    The present study examined children's compliance and noncompliance behaviors in response to parental control strategies in 20 children with high-functioning autism (HFA) and 20 matched typically-developing children. Observational coding was used to measure child compliance (committed, situational), noncompliance (passive, defiance, self-assertion,…

  8. Design, analysis, and testing of high frequency passively damped struts

    NASA Technical Reports Server (NTRS)

    Yiu, Y. C.; Davis, L. Porter; Napolitano, Kevin; Ninneman, R. Rory

    1993-01-01

    Objectives of the research are: (1) to develop design requirements for damped struts to stabilize control system in the high frequency cross-over and spill-over range; (2) to design, fabricate and test viscously damped strut and viscoelastically damped strut; (3) to verify accuracy of design and analysis methodology of damped struts; and (4) to design and build test apparatus, and develop data reduction algorithm to measure strut complex stiffness. In order to meet the stringent performance requirements of the SPICE experiment, the active control system is used to suppress the dynamic responses of the low order structural modes. However, the control system also inadvertently drives some of the higher order modes unstable in the cross-over and spill-over frequency range. Passive damping is a reliable and effective way to provide damping to stabilize the control system. It also improves the robustness of the control system. Damping is designed into the SPICE testbed as an integral part of the control-structure technology.

  9. Changes in passive tension of muscle in humans and animals after eccentric exercise

    PubMed Central

    Whitehead, N P; Weerakkody, N S; Gregory, J E; Morgan, D L; Proske, U

    2001-01-01

    This is a report of experiments on ankle extensor muscles of human subjects and a parallel series on the medial gastrocnemius of the anaesthetised cat, investigating the origin of the rise in passive tension after a period of eccentric exercise. Subjects exercised their triceps surae of one leg eccentrically by walking backwards on an inclined, forward-moving treadmill. Concentric exercise required walking forwards on a backwards-moving treadmill. For all subjects the other leg acted as a control. Immediately after both eccentric and concentric exercise there was a significant drop in peak active torque, but only after eccentric exercise was this accompanied by a shift in optimum angle for torque generation and a rise in passive torque. In the eccentrically exercised group some swelling and soreness developed but not until 24 h post-exercise. In the animal experiments the contracting muscle was stretched by 6 mm at 50 mm s−1 over a length range symmetrical about the optimum length for tension generation. Measurements of passive tension were made before and after the eccentric contractions, using small stretches to a range of muscle lengths, or with large stretches covering the full physiological range. After 150 eccentric contractions, passive tension was significantly elevated over most of the range of lengths. Measurements of work absorption during stretch-release cycles showed significant increases after the contractions. It is suggested that the rise in passive tension in both human and animal muscles after eccentric contractions is the result of development of injury contractures in damaged muscle fibres. PMID:11389215

  10. AMPS data management requirements study. [user manuals (computer programs)/display devices - computerized simulation/experimentation/ionosphere

    NASA Technical Reports Server (NTRS)

    1975-01-01

    A data simulation is presented for instruments and associated control and display functions required to perform controlled active experiments of the atmosphere. A comprehensive user's guide is given for the data requirements and software developed for the following experiments: (1) electromagnetic wave transmission; (2) passive observation of ambient plasmas; (3) ionospheric measurements with a subsatellite; (4) electron accelerator beam measurements; and (5) measurement of acoustic gravity waves in the sodium layer using lasers. A complete description of each experiment is given.

  11. Commissioning a passive-scattering proton therapy nozzle for accurate SOBP delivery

    PubMed Central

    Engelsman, M.; Lu, H.-M.; Herrup, D.; Bussiere, M.; Kooy, H. M.

    2009-01-01

    Proton radiotherapy centers that currently use passively scattered proton beams do field specific calibrations for a non-negligible fraction of treatment fields, which is time and resource consuming. Our improved understanding of the passive scattering mode of the IBA universal nozzle, especially of the current modulation function, allowed us to re-commission our treatment control system for accurate delivery of SOBPs of any range and modulation, and to predict the output for each of these fields. We moved away from individual field calibrations to a state where continued quality assurance of SOBP field delivery is ensured by limited system-wide measurements that only require one hour per week. This manuscript reports on a protocol for generation of desired SOBPs and prediction of dose output. PMID:19610306

  12. A New Method for the Adaptive Control of Vortex-Wall Interactions

    NASA Technical Reports Server (NTRS)

    Koumoutsakos, P.

    1996-01-01

    The control of vortical flows is gaining significance in the design of aeronautical and marine structures. While passive devices have been used effectively in the past, active control strategies have the potential of allowing a leap in the performance of future configurations. The efficiency of control schemes is strongly dependent on the development of accurate flow models that can be devised using information that is available not only from numerical solutions of the governing Navier-Stokes equations but also can be measured experimentally. In that context it is desirable to construct adaptive control schemes using information that can be measured at the wall.

  13. Passivity-Based Control for Two-Wheeled Robot Stabilization

    NASA Astrophysics Data System (ADS)

    Uddin, Nur; Aryo Nugroho, Teguh; Agung Pramudito, Wahyu

    2018-04-01

    A passivity-based control system design for two-wheeled robot (TWR) stabilization is presented. A TWR is a statically-unstable non-linear system. A control system is applied to actively stabilize the TWR. Passivity-based control method is applied to design the control system. The design results in a state feedback control law that makes the TWR closed loop system globally asymptotically stable (GAS). The GAS is proven mathematically. The TWR stabilization is demonstrated through computer simulation. The simulation results show that the designed control system is able to stabilize the TWR.

  14. Development of a Passive Liquid Valve (PLV) Utilizing a Pressure Equilibrium Phenomenon on the Centrifugal Microfluidic Platform

    PubMed Central

    Al-Faqheri, Wisam; Ibrahim, Fatimah; Thio, Tzer Hwai Gilbert; Bahari, Norulain; Arof, Hamzah; Rothan, Hussin A.; Yusof, Rohana; Madou, Marc

    2015-01-01

    In this paper, we propose an easy-to-implement passive liquid valve (PLV) for the microfluidic compact-disc (CD). This valve can be implemented by introducing venting chambers to control the air flow of the source and destination chambers. The PLV mechanism is based on equalizing the main forces acting on the microfluidic CD (i.e., the centrifugal and capillary forces) to control the burst frequency of the source chamber liquid. For a better understanding of the physics behind the proposed PLV, an analytical model is described. Moreover, three parameters that control the effectiveness of the proposed valve, i.e., the liquid height, liquid density, and venting chamber position with respect to the CD center, are tested experimentally. To demonstrate the ability of the proposed PLV valve, microfluidic liquid switching and liquid metering are performed. In addition, a Bradford assay is performed to measure the protein concentration and evaluated in comparison to the benchtop procedure. The result shows that the proposed valve can be implemented in any microfluidic process that requires simplicity and accuracy. Moreover, the developed valve increases the flexibility of the centrifugal CD platform for passive control of the liquid flow without the need for an external force or trigger. PMID:25723143

  15. Development of a passive liquid valve (PLV) utilizing a pressure equilibrium phenomenon on the centrifugal microfluidic platform.

    PubMed

    Al-Faqheri, Wisam; Ibrahim, Fatimah; Thio, Tzer Hwai Gilbert; Bahari, Norulain; Arof, Hamzah; Rothan, Hussin A; Yusof, Rohana; Madou, Marc

    2015-02-25

    In this paper, we propose an easy-to-implement passive liquid valve (PLV) for the microfluidic compact-disc (CD). This valve can be implemented by introducing venting chambers to control the air flow of the source and destination chambers. The PLV mechanism is based on equalizing the main forces acting on the microfluidic CD (i.e., the centrifugal and capillary forces) to control the burst frequency of the source chamber liquid. For a better understanding of the physics behind the proposed PLV, an analytical model is described. Moreover, three parameters that control the effectiveness of the proposed valve, i.e., the liquid height, liquid density, and venting chamber position with respect to the CD center, are tested experimentally. To demonstrate the ability of the proposed PLV valve, microfluidic liquid switching and liquid metering are performed. In addition, a Bradford assay is performed to measure the protein concentration and evaluated in comparison to the benchtop procedure. The result shows that the proposed valve can be implemented in any microfluidic process that requires simplicity and accuracy. Moreover, the developed valve increases the flexibility of the centrifugal CD platform for passive control of the liquid flow without the need for an external force or trigger.

  16. Seven Passive 1-h Hypoxia Exposures Do Not Prevent AMS in Susceptible Individuals.

    PubMed

    Faulhaber, Martin; Pocecco, Elena; Gatterer, Hannes; Niedermeier, Martin; Huth, Maike; Dünnwald, Tobias; Menz, Verena; Bernardi, Luciano; Burtscher, Martin

    2016-12-01

    The present study evaluated the effects of a preacclimatization program comprising seven passive 1-h exposures to 4500-m normobaric hypoxia on the prevalence and severity of acute mountain sickness (AMS) during a subsequent exposure to real high altitude in persons susceptible to AMS. The project was designed as a randomized controlled trial including 32 healthy female and male participants with known susceptibility to AMS symptoms. After baseline measurements, participants were randomly assigned to the hypoxia or the control group to receive the preacclimatization program (seven passive 1-h exposures within 7 d to normobaric hypoxia or sham hypoxia). After completing preacclimatization, participants were transported (bus, cog railway) to real high altitude (3650 m, Mönchsjoch Hut, Switzerland) and stayed there for 45 h (two nights). Symptoms of AMS and physiological responses were determined repeatedly. AMS incidence and severity did not significantly differ between groups during the high-altitude exposure. In total, 59% of the hypoxia and 67% of the control group suffered from AMS at one or more time points during the high-altitude exposure. Hypoxic and hypercapnic ventilatory responses were not affected by the preacclimatization program. Resting ventilation at high altitude tended to be higher (P = 0.06) in the hypoxia group compared with the control group. No significant between-group differences were detected for heart rate variability, arterial oxygen saturation, and hematological and ventilatory parameters during the high-altitude exposure. Preacclimatization using seven passive 1-h exposures to normobaric hypoxia corresponding to 4500 m did not prevent AMS development during a subsequent high-altitude exposure in AMS-susceptible persons.

  17. How do PDMS-coated stir bars used as passive samplers integrate concentration peaks of pesticides in freshwater?

    PubMed

    Assoumani, A; Margoum, C; Lombard, A; Guillemain, C; Coquery, M

    2017-03-01

    Passive samplers are theoretically capable of integrating variations of concentrations of micropollutants in freshwater and providing accurate average values. However, this property is rarely verified and quantified experimentally. In this study, we investigated, in controlled conditions, how the polydimethylsiloxane-coated stir bars (passive Twisters) can integrate fluctuating concentrations of 20 moderately hydrophilic to hydrophobic pesticides (2.18 < Log K ow  < 5.51). In the first two experiments, we studied the pesticide accumulation in the passive Twisters during high concentration peaks of various durations in tap water. We then followed their elimination from the passive Twisters placed in non-contaminated water (experiment no. 1) or in water spiked at low concentrations (experiment no. 2) for 1 week. In the third experiment, we assessed the accuracy of the time-weighted average concentrations (TWAC) obtained from the passive Twisters exposed for 4 days to several concentration variation scenarios. We observed little to no elimination of hydrophobic pesticides from the passive Twisters placed in non-contaminated water and additional accumulation when placed in water spiked at low concentrations. Moreover, passive Twisters allowed determining accurate TWAC (accuracy, determined by TWAC-average measured concentrations ratios, ranged from 82 to 127 %) for the pesticides with Log K ow higher than 4.2. In contrast, fast and large elimination was observed for the pesticides with Log K ow lower than 4.2 and poorer TWAC accuracy (ranging from 32 to 123 %) was obtained.

  18. Re-active Passive (RAP) Devices for Control of Noise Transmission through a Panel

    NASA Technical Reports Server (NTRS)

    Carneal, James P.; Giovanardi, Marco; Fuller, Chris R.; Palumbo, Daniel L.

    2008-01-01

    Re-Active Passive (RAP) devices have been developed to control low frequency (<1000 Hz) noise transmission through a panel. These devices use a combination of active, re-active, and passive technologies packaged into a single unit to control a broad frequency range utilizing the strength of each technology over its best suited frequency range. The RAP device uses passive constrained layer damping to cover the relatively high frequency range (>200 Hz), reactive distributed vibration absorber) to cover the medium frequency range (75 to 250 Hz), and active control for controlling low frequencies (<200 Hz). The device was applied to control noise transmission through a panel mounted in a transmission loss test facility. Experimental results are presented for the bare panel, and combinations of passive treatment, reactive treatment, and active control. Results indicate that three RAP devices were able to increase the overall broadband (15-1000 Hz) transmission loss by 9.4 dB. These three devices added a total of 285 grams to the panel mass of 6.0 kg, or approximately 5%, not including control electronics.

  19. Turbulent flow separation control through passive techniques

    NASA Technical Reports Server (NTRS)

    Lin, J. C.; Howard, F. G.; Selby, G. V.

    1989-01-01

    Several passive separation control techniques for controlling moderate two-dimensional turbulent flow separation over a backward-facing ramp are studied. Small transverse and swept grooves, passive porous surfaces, large longitudinal grooves, and vortex generators were among the techniques used. It was found that, unlike the transverse and longitudinal grooves of an equivalent size, the 45-deg swept-groove configurations tested tended to enhance separation.

  20. Comparing glycaemic benefits of Active Versus passive lifestyle Intervention in kidney Allograft Recipients (CAVIAR): study protocol for a randomised controlled trial.

    PubMed

    Wilcox, Joanne; Waite, Chantelle; Tomlinson, Lyndsey; Driscoll, Joanne; Karim, Asra; Day, Edward; Sharif, Adnan

    2016-08-22

    Lifestyle modification is widely recommended to kidney allograft recipients post transplantation due to the cardiometabolic risks associated with immunosuppression including new-onset diabetes, weight gain and cardiovascular events. However, we have no actual evidence that undertaking lifestyle modification protects from any adverse outcomes post transplantation. The aim of this study is to compare whether a more proactive versus passive interventional approach to modify lifestyle is associated with superior outcomes post kidney transplantation. We designed this prospective, single-centre, open-label, randomised controlled study to compare the efficacy of active versus passive lifestyle intervention for kidney allograft recipients early post transplantation. A total of 130 eligible patients, who are stable, nondiabetic and between 3 and 24 months post kidney transplantation, will be recruited. Randomisation is being undertaken by random block permutations into passive (n = 65, leaflet guidance only) versus active lifestyle modification (n = 65, supervised intervention) over a 6-month period. Supervised intervention is being facilitated by two dietitians during the 6-month intervention period to provide continuous lifestyle intervention guidance, support and encouragement. Both dietitians are accredited with behavioural intervention skills and will utilise motivational aids to support study recruits randomised to active intervention. The primary outcome is change in abnormal glucose metabolism parameters after 6 months of comparing active versus passive lifestyle intervention. Secondary outcomes include changes in a wide array of cardiometabolic parameters, kidney allograft function and patient-reported outcome measures. Long-term tracking of patients via data linkage to electronic patient records and national registries will facilitate long-term comparison of outcomes after active versus passive lifestyle intervention beyond the 6-month intervention period. This is the first randomised controlled study to investigate the benefits of active versus passive lifestyle intervention in kidney allograft recipients for the prevention of abnormal cardiometabolic outcomes. In addition, this is the first example of utilising behaviour therapy intervention post kidney transplantation to achieve clinically beneficial outcomes, which has potential implications on many spheres of post-transplant care. This study was registered with the Clinical Trials Registry on 27 August 2014 (ClinicalTrials.org Identifier: NCT02233491 ).

  1. Gait and balance of transfemoral amputees using passive mechanical and microprocessor-controlled prosthetic knees.

    PubMed

    Kaufman, K R; Levine, J A; Brey, R H; Iverson, B K; McCrady, S K; Padgett, D J; Joyner, M J

    2007-10-01

    Microprocessor-controlled knee joints appeared on the market a decade ago. These joints are more sophisticated and more expensive than mechanical ones. The literature is contradictory regarding changes in gait and balance when using these sophisticated devices. This study employed a crossover design to assess the comparative performance of a passive mechanical knee prosthesis compared to a microprocessor-controlled knee joint in 15 subjects with an above-knee amputation. Objective measurements of gait and balance were obtained. Subjects demonstrated significantly improved gait characteristics after receiving the microprocessor-controlled prosthetic knee joint (p<0.01). Improvements in gait were a transition from a hyperextended knee to a flexed knee during loading response which resulted in a change from an internal knee flexor moment to a knee extensor moment. The participants' balance also improved (p<0.01). All conditions of the Sensory Organization Test (SOT) demonstrated improvements in equilibrium score. The composite score also increased. Transfemoral amputees using a microprocessor-controlled knee have significant improvements in gait and balance.

  2. Design and application of ion-implanted polySi passivating contacts for interdigitated back contact c-Si solar cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Guangtao; Ingenito, Andrea; Hameren, Nienke van

    2016-01-18

    Ion-implanted passivating contacts based on poly-crystalline silicon (polySi) are enabled by tunneling oxide, optimized, and used to fabricate interdigitated back contact (IBC) solar cells. Both n-type (phosphorous doped) and p-type (boron doped) passivating contacts are fabricated by ion-implantation of intrinsic polySi layers deposited via low-pressure chemical vapor deposition and subsequently annealed. The impact of doping profile on the passivation quality of the polySi doped contacts is studied for both polarities. It was found that an excellent surface passivation could be obtained by confining as much as possible the implanted-and-activated dopants within the polySi layers. The doping profile in the polySimore » was controlled by modifying the polySi thickness, the energy and dose of ion-implantation, and the temperature and time of annealing. An implied open-circuit voltage of 721 mV for n-type and 692 mV for p-type passivating contacts was achieved. Besides the high passivating quality, the developed passivating contacts exhibit reasonable high conductivity (R{sub sh n-type} = 95 Ω/□ and R{sub sh p-type} = 120 Ω/□). An efficiency of 19.2% (V{sub oc} = 673 mV, J{sub sc} = 38.0 mA/cm{sup 2}, FF = 75.2%, and pseudo-FF = 83.2%) was achieved on a front-textured IBC solar cell with polySi passivating contacts as both back surface field and emitter. By improving the front-side passivation, a V{sub OC} of 696 mV was also measured.« less

  3. Passive sampler for PM10-2.5 aerosol.

    PubMed

    Leith, David; Sommerlatt, Darrell; Boundy, Maryanne G

    2007-03-01

    This study investigates the use of a small passive sampler for aerosol particles to determine particulate matter (PM)10-2.5 concentrations in outdoor air. The passive sampler collects particles by gravity, diffusion, and convective diffusion onto a glass coverslip that is then examined with an optical microscope; digital images are processed with free software and the resultant PM10-2.5 concentrations determined. Both the samplers and the analyses are relatively inexpensive. Passive samplers were collocated with Federal Reference Method (FRM) samplers in Chapel Hill, NC; Phoenix, AZ; and Birmingham, AL; for periods from 5 to 15 days. Particles consisted primarily of inorganic dusts at some sites and a mix of industrial and inorganic materials at other sites. Measured concentrations ranged from < 10 microg/m3 to approximately 40 microg/m3. Overall, PM10-2.5 concentrations measured with the passive samplers were within approximately 1 standard deviation of concentrations measured with the FRM samplers. Concentrations determined with passive samplers depend on assumptions about particle density and shape factors and may also depend somewhat on local wind speed and turbulence; accurate values for these parameters may not be known. The degree of agreement between passive and FRM concentrations measured here suggests that passive measurements may not be overly dependent on accurate knowledge of these parameters.

  4. Thick-Filament Strain and Interfilament Spacing in Passive Muscle: Effect of Titin-Based Passive Tension

    PubMed Central

    Irving, Thomas; Wu, Yiming; Bekyarova, Tanya; Farman, Gerrie P.; Fukuda, Norio; Granzier, Henk

    2011-01-01

    We studied the effect of titin-based passive tension on sarcomere structure by simultaneously measuring passive tension and low-angle x-ray diffraction patterns on passive fiber bundles from rabbit skinned psoas muscle. We used a stretch-hold-release protocol with measurement of x-ray diffraction patterns at various passive tension levels during the hold phase before and after passive stress relaxation. Measurements were performed in relaxing solution without and with dextran T-500 to compress the lattice toward physiological levels. The myofilament lattice spacing was measured in the A-band (d1,0) and Z-disk (dZ) regions of the sarcomere. The axial spacing of the thick-filament backbone was determined from the sixth myosin meridional reflection (M6) and the equilibrium positions of myosin heads from the fourth myosin layer line peak position and the I1,1/I1,0 intensity ratio. Total passive tension was measured during the x-ray experiments, and a differential extraction technique was used to determine the relations between collagen- and titin-based passive tension and sarcomere length. Within the employed range of sarcomere lengths (∼2.2–3.4 μm), titin accounted for >80% of passive tension. X-ray results indicate that titin compresses both the A-band and Z-disk lattice spacing with viscoelastic behavior when fibers are swollen after skinning, and elastic behavior when the lattice is reduced with dextran. Titin also increases the axial thick-filament spacing, M6, in an elastic manner in both the presence and absence of dextran. No changes were detected in either I1,1/I1,0 or the position of peaks on the fourth myosin layer line during passive stress relaxation. Passive tension and M6 measurements were converted to thick-filament compliance, yielding a value of ∼85 m/N, which is several-fold larger than the thick-filament compliance determined by others during the tetanic tension plateau of activated intact muscle. This difference can be explained by the fact that thick filaments are more compliant at low tension (passive muscle) than at high tension (tetanic tension). The implications of our findings are discussed. PMID:21402032

  5. Evaluating the Relationship between Equilibrium Passive ...

    EPA Pesticide Factsheets

    This review evaluates passive sampler uptake of hydrophobic organic contaminants (HOCs) as it relates to organism bioaccumulation in the water column and interstitial water. Fifty-five studies were found where both passive samplers and organism bioaccumulation were used to measured water quality. Of these investigations, 19 provided direct comparisons relating passive sampler concentrations and organism bioaccumulation. Passive sampling polymers included in the review were: low density polyethylene (LDPE); polyoxymethylene (POM); and polydimethylsiloxane (PDMS), and organisms ranged from polychaetes and oligochaetes to bivalves, aquatic insects, and gastropods. Log-linear regressions correlating bioaccumulation (CL) and passive sampler concentration (CPS) were used to assess the strength of observed relationships. In general, the passive sampler concentrations resulted in statistically-significant, logarithmic, predictive relationships, most of which were within one to two orders of magnitude of measured bioaccumulation. Overall, bioaccumulation values were greater than passive sampler concentrations. A mean ratio of CL to CPS was 10.8 ± 18.4 (n = 609) for available data. Given that all studies presented resulted in a strong CL versus CPS relationship suggests that using passive sampling as a surrogate for organism bioaccumulation is viable when biomonitoring organisms are not available. Passive sampling based measurements can provide useful information for ma

  6. Bone structure and quality preserved by active versus passive muscle exercise in 21 days tail-suspended rats

    NASA Astrophysics Data System (ADS)

    Luan, Huiqin; Sun, Lian-wen; Fan, Yu-bo

    2012-07-01

    Humans in Space suffer from microgravity-induced attenuated bone strength that needs to be addressed by on-orbit exercise countermeasures. However, exercise prescriptions so far did not adequately counteract the bone loss of astronauts in spaceflight because even active muscle contractions were converted to passive mode during voluntary bouts. We tested our hypothesis in unloaded rat hind limb following twenty-one days of tail-suspension (TS) combined with exercise using a hind limb stepper device designed by our group. Female Sprague Dawley rats (250g b.wt.) were divided into four groups (n=5, each): TS-only (hind limb unloading), TS plus passive mode exercise (TSP) induced by mechanically-forced passive hind limb lifting, TS plus active mode exercise (TSA) entrained by plantar electrostimulation, and control (CON) group. Standard measures of bone (e.g., mineral density, trabecular microstructure, biomechanics and ash weight) were monitored. Results provided that the attenuated properties of unloaded hind limb bone in TS-rats were more effectively supported by active mode than by passive mode motions. We here propose a modified exercise regimen combined with spontaneous muscle contractions thereby considering the biodynamic demands of both muscle and bone during resistive-load exercise in microgravity. Keywords: rat, BMD, DXA, passive exercise, active exercise, bone loss, tail suspension, spaceflight analogue, exercise countermeasure.

  7. Control Model for Dampening Hand Vibrations Using Information of Internal and External Coordinates

    PubMed Central

    Togo, Shunta; Kagawa, Takahiro; Uno, Yoji

    2015-01-01

    In the present study, we investigate a control mechanism that dampens hand vibrations. Here, we propose a control method with two components to suppress hand vibrations. The first is a passive suppression method that lowers the joint stiffness to passively dampen the hand vibrations. The second is an active suppression method that adjusts an equilibrium point based on skyhook control to actively dampen the hand vibrations. In a simulation experiment, we applied these two methods to dampen hand vibrations during the shoulder’s horizontal oscillation. We also conducted a measurement experiment wherein a subject’s shoulder was sinusoidally oscillated by a platform that generated horizontal oscillations. The results of the measurement experiments showed that the jerk of each part of the arm in a task using a cup filled with water was smaller than the shoulder jerk and that in a task with a cup filled with stones was larger than the shoulder jerk. Moreover, the amplitude of the hand trajectory in both horizontal and vertical directions was smaller in a task using a cup filled with water than in a task using a cup filled with stones. The results of the measurement experiments were accurately reproduced by the active suppression method based on skyhook control. These results suggest that humans dampen hand vibrations by controlling the equilibrium point through the information of the external workspace and the internal body state rather than by lowering joint stiffness only by using internal information. PMID:25876037

  8. Relationships Between Varus–Valgus Laxity of the Severely Osteoarthritic Knee and Gait, Instability, Clinical Performance, and Function

    PubMed Central

    Freisinger, Gregory M.; Hutter, Erin E.; Lewis, Jacqueline; Granger, Jeffrey F.; Glassman, Andrew H.; Beal, Matthew D.; Pan, Xueliang; Schmitt, Laura C.; Siston, Robert A.; Chaudhari, Ajit M.W.

    2017-01-01

    Increased varus–valgus laxity has been reported in individuals with knee osteoarthritis (OA) compared to controls. However, the majority of previous investigations may not report truly passive joint laxity, as their tests have been performed on conscious participants who could be guarding against motion with muscle contraction during laxity evaluation. The purpose of this study was to investigate how a measure of passive knee laxity, recorded when the participant is under anesthesia, is related to varus–valgus excursion during gait, clinical measures of performance, perceived instability, and self-reported function in participants with severe knee OA. We assessed passive varus–valgus knee laxity in 29 participants (30 knees) with severe OA, as they underwent total knee arthroplasty (TKA). Participants also completed gait analysis, clinical assessment of performance (6-min walk (6 MW), stair climbing test (SCT), isometric knee strength), and self-reported measures of function (perceived instability, Knee injury, and Osteoarthritis Outcome Score (KOOS) a median of 18 days before the TKA procedure. We observed that greater passive varus–valgus laxity was associated with greater varus–valgus excursion during gait (R2 =0.34, p =0.002). Significant associations were also observed between greater laxity and greater isometric knee extension strength (p =0.014), farther 6 MW distance (p =0.033) and shorter SCT time (p =0.046). No relationship was observed between passive varus–valgus laxity and isometric knee flexion strength, perceived instability, or any KOOS subscale. The conflicting associations between laxity, frontal excursion during gait, and functional performance suggest a complex relationship between laxity and knee cartilage health, clinical performance, and self-reported function that merits further study. PMID:27664972

  9. The Passive Series Stiffness That Optimizes Torque Tracking for a Lower-Limb Exoskeleton in Human Walking

    PubMed Central

    Zhang, Juanjuan; Collins, Steven H.

    2017-01-01

    This study uses theory and experiments to investigate the relationship between the passive stiffness of series elastic actuators and torque tracking performance in lower-limb exoskeletons during human walking. Through theoretical analysis with our simplified system model, we found that the optimal passive stiffness matches the slope of the desired torque-angle relationship. We also conjectured that a bandwidth limit resulted in a maximum rate of change in torque error that can be commanded through control input, which is fixed across desired and passive stiffness conditions. This led to hypotheses about the interactions among optimal control gains, passive stiffness and desired quasi-stiffness. Walking experiments were conducted with multiple angle-based desired torque curves. The observed lowest torque tracking errors identified for each combination of desired and passive stiffnesses were shown to be linearly proportional to the magnitude of the difference between the two stiffnesses. The proportional gains corresponding to the lowest observed errors were seen inversely proportional to passive stiffness values and to desired stiffness. These findings supported our hypotheses, and provide guidance to application-specific hardware customization as well as controller design for torque-controlled robotic legged locomotion. PMID:29326580

  10. Significantly enhanced thermal conductivity of indium arsenide nanowires via sulfur passivation.

    PubMed

    Xiong, Yucheng; Tang, Hao; Wang, Xiaomeng; Zhao, Yang; Fu, Qiang; Yang, Juekuan; Xu, Dongyan

    2017-10-16

    In this work, we experimentally investigated the effect of sulfur passivation on thermal transport in indium arsenide (InAs) nanowires. Our measurement results show that thermal conductivity can be enhanced by a ratio up to 159% by sulfur passivation. Current-voltage (I-V) measurements were performed on both unpassivated and S-passivated InAs nanowires to understand the mechanism of thermal conductivity enhancement. We observed a remarkable improvement in electrical conductivity upon sulfur passivation and a significant contribution of electrons to thermal conductivity, which account for the enhanced thermal conductivity of the S-passivated InAs nanowires.

  11. Carryover effects associated with the single-trial passive avoidance learning task in the young chick.

    PubMed

    Crowe, Simon F; Hale, Matthew W

    2002-09-01

    The single-trial passive avoidance task is a useful procedure for examining learning and memory in the young chick. However, it has recently been suggested that discrepant results reported by different laboratories are due to differences in training procedure. The present study investigated a number of parameters surrounding the passive avoidance task, using day-old White Leghorn, Black Australorp cockerels. The results suggested that presentation of a water-dipped bead immediately after the aversive bead significantly altered retention levels. In addition, when the water-dipped bead was presented after the aversive bead, chicks failed to discriminate between beads for a period of 10 min following exposure to the aversant experience. A novel variant of the passive avoidance procedure, involving pretraining with a water-dipped red bead, training with an aversant-coated red bead, and testing with a dry red bead, was evaluated. A measure of avoidance was calculated using all three trials. It is suggested that the use of a single bead, measured both before and after the training experience and using both aversant- and water-trained controls, results in the most concise characterization of memory-related phenomena in the chick which is not contaminated by a carryover effect from the aversive training experience to the nonaversive bead.

  12. Patellofemoral pain syndrome and its association with hip, ankle, and foot function in 16- to 18-year-old high school students: a single-blind case-control study.

    PubMed

    Mølgaard, Carsten; Rathleff, Michael Skovdal; Simonsen, Ole

    2011-01-01

    An increased pronated foot posture is believed to contribute to patellofemoral pain syndrome (PFPS), but the relationship between these phenomena is still controversial. The objectives of this study were to investigate the prevalence of PFPS in high school students and to compare passive internal and external hip rotation, passive dorsiflexion, and navicular drop and drift between healthy high school students and students with PFPS. All 16- to 18-year-old students in a Danish high school were invited to join this single-blind case-control study (N = 299). All of the students received a questionnaire regarding knee pain. The main outcome measurements were prevalence of PFPS, navicular drop and drift, passive ankle dorsiflexion, passive hip rotation in the prone position, and activity level. The case group consisted of all students with PFPS. From the same population, a randomly chosen control group was formed. The prevalence of knee pain was 25%. Of the 24 students with knee pain, 13 were diagnosed as having PFPS. This corresponds to a PFPS prevalence of 6%. Mean navicular drop and drift were higher in the PFPS group versus the control group (navicular drop: 4.2 mm [95% confidence interval (CI), 3.2-5.3 mm] versus 2.9 mm [95% CI, 2.5-3.3 mm]; and navicular drift: 2.6 mm [95% CI, 1.6-3.7 mm] versus 1.4 mm [95% CI, 0.9-2.0 mm]). Higher passive ankle dorsiflexion was also identified in the PFPS group (22.2° [95% CI, 18°-26°] versus 17.7° [95% CI, 15°-20°]). This study demonstrated greater navicular drop, navicular drift, and dorsiflexion in high school students with PFPS compared with healthy students and highlights that foot posture is important to consider as a factor where patients with PFPS diverge from healthy individuals.

  13. A comparison of the effect of a variety of thermal and vibratory modalities on skin temperature and blood flow in healthy volunteers

    PubMed Central

    Lohman, Everett B.; Bains, Gurinder S.; Lohman, Trevor; DeLeon, Michael; Petrofsky, Jerrold Scott

    2011-01-01

    Summary Background Circulation plays an essential role in tissue healing. Moist heat and warm water immersion have been shown to increase skin circulation; however, these heating modalities can cause burns. Recent research has shown that passive vibration can also increase circulation but without the risk of burns. Material/Methods The aim of this study is to compare the effects of short-duration vibration, moist heat, and a combination of the two on skin blood flow (SBF) and skin temperature (ST). Ten (10) subjects, 5 female and 5 male, aged 20–30 years of age, received two interventions a day for 3 consecutive days: Intervention 1 – Active vibration only (vibration exercise), Intervention 2 – passive vibration only, Intervention 3 – moist heat only, Intervention 4 – passive vibration combined with moist heat, Intervention 5 – a commercial massaging heating pad, and Intervention 6 – no intervention, resting in supine only (control). SBF and ST were measured using a laser Doppler imager during the 10 minute intervention and then throughout the nine minute recovery period. Results The mean skin blood flow following a ten-minute intervention of the combination of passive vibration and moist heat was significantly different from the control, active vibration, and the commercial massaging heating pad. Skin temperature following the ten-minute interventions of moist heat alone and passive vibration alone were both significantly different from the commercial massaging heating pad and active vibration interventions. Conclusions The combination of passive vibration and moist heat produced the greatest increase in skin blood flow and the second highest increase in skin blood flow nine minutes post application. PMID:21873956

  14. 26 CFR 1.267(a)-3 - Deduction of amounts owed to related foreign persons.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... company, controlled foreign corporation, or passive foreign investment company—(i) Foreign personal... requirements of the controlled foreign corporation provisions (sections 951 through 964). (iii) Passive foreign... related foreign person that is a passive foreign investment company within the meaning of section 1296...

  15. Strategy for Passivating Char Efficiently at the Pilot Scale

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dunning, Timothy C

    Fast pyrolysis is a promising pathway for the commercialization of liquid transportation fuels from biomass. Fast pyrolysis is performed at moderate heat (450-600 degrees Celcius) in an oxygen-deficient environment. One of the products of fast pyrolysis is biochar, which is often used as a heat source or as a soil amendment. Biochar is a partially reacted solid that is created in the production of bio-oil during fast pyrolysis. Biochar produced at these conditions contains significant quantities of carbon that adsorb oxygen when exposed to air. Biochar adsorption of oxygen is an exothermic process that may generate sufficient heat for combustionmore » in ambient air. Biochar is also a self-insulating material which compounds the effects of heat generated internally. These factors lead to safety concerns and material handling difficulties. The Thermochemical Process Development Unit at the National Renewable Energy Laboratory operates a pilot plant that may be configured for fast pyrolysis, gasification, and will be introducing catalytic fast pyrolysis capabilities in 2018. The TCPDU designed and installed a system to introduce oxygen to collected biochar systematically for a controlled passivation. Biochar is collected and cooled in an oxygen deficient environment during fast pyrolysis. Oxygen is then introduced to the biochar on a mass flow basis. A sparger imbedded within the biochar sample near the bottom of the bed flows air diluted with nitrogen into the char bed, and excess gasses are removed from the top of the collection drum, above the char bed. Pressure within the collection drum is measured indicating adequate flow through filters. Sample weight is recorded before and after passivation. During passivation, temperature is measured at 18 points within the char bed. Oxygen content and temperature are measured leaving the char bed. Maximum temperature parameters were established to ensure operator safety during biochar passivation. Extensive passivation data was collected on pine and blended feedstocks and has been analyzed to characterize the exotherm of char samples. Observations and data collected while passivating char will be discussed.« less

  16. Descriptive profile of hip range of motion in elite tennis players.

    PubMed

    Moreno-Pérez, Victor; Ayala, Francisco; Fernandez-Fernandez, Jaime; Vera-Garcia, Francisco J

    2016-05-01

    To describe the range of motion (ROM) profile (flexion, extension, abduction, internal and external rotation) of the hip in elite tennis players; and (b) to analyse if there are sex-related differences in the hip ROM. Cohort study. Controlled laboratory environment. 81 male and 28 female tennis players completed this study. Descriptive measures of passive hip flexion, extension and abduction, and internal and external active and passive hip rotation ROM were taken. Magnitude-based inferences on differences between sex (males vs. females) and hip (dominant vs. non-dominant) were made by standardising differences. No clinically meaningful bilateral and sex-related differences in any of the hip ROM measures. In addition, it was found that both males and females had restricted mobility measures on hip flexion (<80°), extension (<0°) and abduction (<40°). Furthermore, the 30% of males also presented restricted active and passive hip internal rotation ROM values (<25°). Finally, both males and females had normal mobility measures of hip external rotation ROM (active [>25°] and passive [35°]) Asymmetric hip joint ROM measures found during clinical examination and screening may indicate abnormalities and the need of rehabilitation (e.g., flexibility training). In addition, clinicians should include specific exercises (e.g., stretching) in their conditioning, prevention and rehabilitation programmes aiming to avoid restricted mobility of hip flexion (males = 74°; females = 78°), extension (males = -1.5; females = -0.4), abduction (males = 35°; females = 34°) and internal rotation (males = 30°; females = 35) that might be generated as a consequence of playing tennis. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Adaptation to nonlinear frequency compression in normal-hearing adults: a comparison of training approaches.

    PubMed

    Dickinson, Ann-Marie; Baker, Richard; Siciliano, Catherine; Munro, Kevin J

    2014-10-01

    To identify which training approach, if any, is most effective for improving perception of frequency-compressed speech. A between-subject design using repeated measures. Forty young adults with normal hearing were randomly allocated to one of four groups: a training group (sentence or consonant) or a control group (passive exposure or test-only). Test and training material differed in terms of material and speaker. On average, sentence training and passive exposure led to significantly improved sentence recognition (11.0% and 11.7%, respectively) compared with the consonant training group (2.5%) and test-only group (0.4%), whilst, consonant training led to significantly improved consonant recognition (8.8%) compared with the sentence training group (1.9%), passive exposure group (2.8%), and test-only group (0.8%). Sentence training led to improved sentence recognition, whilst consonant training led to improved consonant recognition. This suggests learning transferred between speakers and material but not stimuli. Passive exposure to sentence material led to an improvement in sentence recognition that was equivalent to gains from active training. This suggests that it may be possible to adapt passively to frequency-compressed speech.

  18. The potential of hybrid micro-vortex generators to control flow separation of NACA 4415 airfoil in subsonic flow

    NASA Astrophysics Data System (ADS)

    Jumahadi, Muhammad Taufiq; Saad, Mohd Rashdan; Idris, Azam Che; Sujipto, Suriyadi; Rahman, Mohd Rosdzimin Abdul

    2018-02-01

    Boundary layer separation is detrimental to the lift and drag of most aeronautical applications. Many vortex generators (VG), both passive and active have been designed to reduce these drawbacks. This study targets to investigate the effectiveness of hybrid micro-VGs, which combine both active and passive micro-VGs in controlling separation under subsonic conditions. NACA 4415 airfoils installed with passive, active and hybrid micro-VGs each are designed, 3D printed, and tested in a wind tunnel at 26.19 m/s under Re = 2.5x105. The lift and drag measurements from a 3-component force balance prove that hybrid micro-VGs increase lift by up to 21.2%, increase drag by more than 11.3% and improve lift-to-drag ratio by at least 8.6% until up to 33.7%. From this research, it is believed that hybrid micro-VGs are competitive to the performance of active VGs and a better configuration is to be considered to reduce parasitic drag and outstand active VGs.

  19. Photoluminescence and capacitance voltage characterization of GaAs surface passivated by an ultrathin GaN interface control layer

    NASA Astrophysics Data System (ADS)

    Anantathanasarn, Sanguan; Hasegawa, Hideki

    2002-05-01

    A novel surface passivation technique for GaAs using an ultrathin GaN interface control layer (GaN ICL) formed by surface nitridation was characterized by ultrahigh vacuum (UHV) photoluminescence (PL) and capacitance-voltage ( C- V) measurements. The PL quantum efficiency was dramatically enhanced after being passivated by the GaN ICL structure, reaching as high as 30 times of the initial clean GaAs surface. Further analysis of PL data was done by the PL surface state spectroscopy (PLS 3) simulation technique. PL and C- V results are in good agreement indicating that ultrathin GaN ICL reduces the gap states and unpins the Fermi level, realizing a wide movement of Fermi level within the midgap region and reduction of the effective surface recombination velocity by a factor of 1/60. GaN layer also introduced a large negative surface fixed charge of about 10 12 cm -2. A further improvement took place by depositing a Si 3N 4 layer on GaN ICL/GaAs structure.

  20. SiC formation for a solar cell passivation layer using an RF magnetron co-sputtering system

    PubMed Central

    2012-01-01

    In this paper, we describe a method of amorphous silicon carbide film formation for a solar cell passivation layer. The film was deposited on p-type silicon (100) and glass substrates by an RF magnetron co-sputtering system using a Si target and a C target at a room-temperature condition. Several different SiC [Si1-xCx] film compositions were achieved by controlling the Si target power with a fixed C target power at 150 W. Then, structural, optical, and electrical properties of the Si1-xCx films were studied. The structural properties were investigated by transmission electron microscopy and secondary ion mass spectrometry. The optical properties were achieved by UV-visible spectroscopy and ellipsometry. The performance of Si1-xCx passivation was explored by carrier lifetime measurement. PMID:22221730

  1. Humidity Sensing Properties of Paper Substrates and Their Passivation with ZnO Nanoparticles for Sensor Applications

    PubMed Central

    Niarchos, Georgios; Dubourg, Georges; Afroudakis, Georgios; Georgopoulos, Markos; Tsouti, Vasiliki; Makarona, Eleni; Crnojevic-Bengin, Vesna; Tsamis, Christos

    2017-01-01

    In this paper, we investigated the effect of humidity on paper substrates and propose a simple and low-cost method for their passivation using ZnO nanoparticles. To this end, we built paper-based microdevices based on an interdigitated electrode (IDE) configuration by means of a mask-less laser patterning method on simple commercial printing papers. Initial resistive measurements indicate that a paper substrate with a porous surface can be used as a cost-effective, sensitive and disposable humidity sensor in the 20% to 70% relative humidity (RH) range. Successive spin-coated layers of ZnO nanoparticles then, control the effect of humidity. Using this approach, the sensors become passive to relative humidity changes, paving the way to the development of ZnO-based gas sensors on paper substrates insensitive to humidity. PMID:28273847

  2. The design, effectiveness and construction of passive-thermal-control roofing shingles

    NASA Astrophysics Data System (ADS)

    Wolf, L., Jr.

    1982-09-01

    The concept of a passive thermal control roofing shingle, which is a shingle that reflects the summer sun and absorbs the winter sun, is discussed. It is indicated that it is possible to design shingles for particular latitudes and styles of roof which absorb nearly all of the winter solar energy and reflect nearly all of the summer solar energy. Calculations of the energy savings and cost effectiveness of the passive thermal control roofing shingle indicate that it is most cost effective on all south facing pitched roofs regardless of heating fuel type, and on flat or east or west facing roofs that are heated with costly fuels such as electricity or heating oil. The shingle is most effective on poorly insulated structures. The feasibility of using the passive thermal control roofing shingle in conjunction with a heat pump to pump heat absorbed by the shingle into a well insulated structure is demonstrated. Construction of a variety of models of the passive thermal control roofing shingle illustrate numerous alternate methods of manufacture. A profile extruded, plastic, glazed shingle appears to be the most promising approach. Use of a glazed shingle can increase the effectiveness of the passive thermal control roofing shingle by reducing convective heat losses.

  3. Simulation and analysis of vertical displacement characteristics of three wheels reverse trike vehicle with PID controller application

    NASA Astrophysics Data System (ADS)

    Wibowo, Lambang, Lullus; Erick Chandra, N.; Muhayat, Nurul; Jaka S., B.

    2017-08-01

    The purpose of this research is to obtain a mathematical model (Full Vehicle Model) and compare the performance of passive and active suspension systems of a Three-Wheels Reverse Trike vehicle. Vehicle suspension system should able to provide good steering handling and passenger comfort. Vehicle suspension system generally only uses passive suspension components with fix spring and damper coefficients. An active suspension developed from the traditional (passive) suspension design can directly control the actuator force in the suspension system. In this paper, modeling and simulation of passive and active suspension system for a Full Vehicle Model is performed using Simulink-MATLAB software. Ziegler & Nichols tuning method is used to obtain controller parameters of Proportional Integral Derivative (PID) controller. Comparison between passive and active suspension with PID controller is conducted for disturbances input of single bump road surface profile 0.1 meters. The results are the displacement and acceleration of the vehicle body in the vertical direction of active suspension system with PID control is better in providing handling capabilities and comfort for the driver than of passive suspension system. The acceleration of 1,8G with the down time of 2.5 seconds is smaller than the acceleration of 2.5G with down time of 5.5 seconds.

  4. Using a Ventilation Controller to Optimize Residential Passive Ventilation For Energy and Indoor Air Quality

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Turner, William; Walker, Iain

    One way to reduce the energy impact of providing residential ventilation is to use passive and hybrid systems. However, these passive and hybrid (sometimes called mixed-mode) systems must still meet chronic and acute health standards for ventilation. This study uses a computer simulation approach to examine the energy and indoor air quality (IAQ) implications of passive and hybrid ventilation systems, in 16 California climate zones. Both uncontrolled and flow controlled passive stacks are assessed. A new hybrid ventilation system is outlined that uses an intelligent ventilation controller to minimise energy use, while ensuring chronic and acute IAQ standards are met.more » ASHRAE Standard 62.2-2010 – the United States standard for residential ventilation - is used as the chronic standard, and exposure limits for PM 2.5, formaldehyde and NO 2 are used as the acute standards.The results show that controlled passive ventilation and hybrid ventilation can be used in homes to provide equivalent IAQ to continuous mechanical ventilation, for less use of energy.« less

  5. Drag reduction in a turbulent channel flow using a passivity-based approach

    NASA Astrophysics Data System (ADS)

    Heins, Peter; Jones, Bryn; Sharma, Atul

    2013-11-01

    A new active feedback control strategy for attenuating perturbation energy in a turbulent channel flow is presented. Using a passivity-based approach, a controller synthesis procedure has been devised which is capable of making the linear dynamics of a channel flow as close to passive as is possible given the limitations on sensing and actuation. A controller that is capable of making the linearized flow passive is guaranteed to globally stabilize the true flow. The resulting controller is capable of greatly restricting the amount of turbulent energy that the nonlinearity can feed back into the flow. DNS testing of a controller using wall-sensing of streamwise and spanwise shear stress and actuation via wall transpiration acting upon channel flows with Reτ = 100 - 250 showed significant reductions in skin-friction drag.

  6. Jet flow issuing from an axisymmetric pipe-cavity-orifice nozzle

    NASA Astrophysics Data System (ADS)

    Broučková, Zuzana; Pušková, Pavlína; Trávníček, Zdeněk; Šafařík, Pavel

    2016-03-01

    An axisymmetric air jet flow is experimentally investigated under passive flow control. The jet issues from a pipe of the inner diameter and length of 10 mm and 150 mm which is equipped with an axisymmetric cavity at the pipe end. The cavity operates as a resonator creating self-sustained acoustic excitations of the jet flow. A mechanism of excitations is rather complex - in comparison with a common Helmholtz resonator. The experiments were performed using flow visualization, microphone measurements and time-mean velocity measurements by the Pitot probe. The power spectral density (PSD) and the sound pressure level (SPL) were evaluated from microphone measurements. The jet Reynolds number ranged Re = 1600-18 000. Distinguishable peaks in PSD indicated a function of the resonator. Because the most effective acoustic response was found at higher Re, a majority of experiments focused on higher Re regime. The results demonstrate effects of the passive control on the jet behavior. Fluid mixing and velocity decay along the axis is intensified. It causes shortening of the jet transition region. On the other hand, an inverse proportionality of the velocity decay (u ~ 1/x) in the fully developed region is not changed. The momentum and kinetic energy fluxes decrease more intensively in the controlled jets in comparison with common jets.

  7. A vadose zone water fluxmeter with divergence control

    NASA Astrophysics Data System (ADS)

    Gee, G. W.; Ward, A. L.; Caldwell, T. G.; Ritter, J. C.

    2002-08-01

    Unsaturated water flux densities are needed to quantify water and contaminant transfer within the vadose zone. However, water flux densities are seldom measured directly and often are predicted with uncertainties of an order or magnitude or more. A water fluxmeter was designed, constructed, and tested to directly measure drainage fluxes in field soils. The fluxmeter was designed to minimize divergence. It concentrates flow into a narrow sensing region filled with a fiberglass wick. The wick applies suction, proportional to its length, and passively drains the meter. The meter can be installed in an augured borehole at almost any depth below the root zone. Water flux through the meter is measured with a self-calibrating tipping bucket, with a sensitivity of ~4 mL tip-1. For our meter this is equivalent to detection limit of ~0.1 mm. Passive-wick devices previously have not properly corrected for flow divergence. Laboratory measurements supported predictions of a two-dimensional (2-D) numerical model, which showed that control of the collector height H and knowledge of soil hydraulic properties are required for improving divergence control, particularly at fluxes below 1000 mm yr-1. The water fluxmeter is simple in concept, is inexpensive, and has the capability of providing continuous and reliable monitoring of unsaturated water fluxes ranging from less than 1 mm yr-1 to more than 1000 mm yr-1.

  8. Making working memory work: a meta-analysis of executive-control and working memory training in older adults.

    PubMed

    Karbach, Julia; Verhaeghen, Paul

    2014-11-01

    This meta-analysis examined the effects of process-based executive-function and working memory training (49 articles, 61 independent samples) in older adults (> 60 years). The interventions resulted in significant effects on performance on the trained task and near-transfer tasks; significant results were obtained for the net pretest-to-posttest gain relative to active and passive control groups and for the net effect at posttest relative to active and passive control groups. Far-transfer effects were smaller than near-transfer effects but were significant for the net pretest-to-posttest gain relative to passive control groups and for the net gain at posttest relative to both active and passive control groups. We detected marginally significant differences in training-induced improvements between working memory and executive-function training, but no differences between the training-induced improvements observed in older adults and younger adults, between the benefits associated with adaptive and nonadaptive training, or between the effects in active and passive control conditions. Gains did not vary with total training time. © The Author(s) 2014.

  9. Modeling of Passive Forces of Machine Tool Covers

    NASA Astrophysics Data System (ADS)

    Kolar, Petr; Hudec, Jan; Sulitka, Matej

    The passive forces acting against the drive force are phenomena that influence dynamical properties and precision of linear axes equipped with feed drives. Covers are one of important sources of passive forces in machine tools. The paper describes virtual evaluation of cover passive forces using the cover complex model. The model is able to compute interaction between flexible cover segments and sealing wiper. The result is deformation of cover segments and wipers which is used together with measured friction coefficient for computation of cover total passive force. This resulting passive force is dependent on cover position. Comparison of computational results and measurement on the real cover is presented in the paper.

  10. A Passive Magnetic Bearing Flywheel

    NASA Technical Reports Server (NTRS)

    Siebert, Mark; Ebihara, Ben; Jansen, Ralph; Fusaro, Robert L.; Morales, Wilfredo; Kascak, Albert; Kenny, Andrew

    2002-01-01

    A 100 percent passive magnetic bearing flywheel rig employing no active control components was designed, constructed, and tested. The suspension clothe rotor was provided by two sets of radial permanent magnetic bearings operating in the repulsive mode. The axial support was provided by jewel bearings on both ends of the rotor. The rig was successfully operated to speeds of 5500 rpm, which is 65 percent above the first critical speed of 3336 rpm. Operation was not continued beyond this point because of the excessive noise generated by the air impeller and because of inadequate containment in case of failure. Radial and axial stiffnesses of the permanent magnetic bearings were experimentally measured and then compared to finite element results. The natural damping of the rotor was measured and a damping coefficient was calculated.

  11. Plasma Streamwise Vortex Generators in an Adverse Pressure Gradient

    NASA Astrophysics Data System (ADS)

    Kelley, Christopher; Corke, Thomas; Thomas, Flint

    2013-11-01

    A wind tunnel experiment was conducted to compare plasma streamwise vortex generators (PSVGs) and passive vortex generators (VGs). These devices were installed on a wing section by which the angle of attack could be used to vary the streamwise pressure gradient. The experiment was performed for freestream Mach numbers 0.1-0.2. Three-dimensional velocity components were measured using a 5-hole Pitot probe in the boundary layer. These measurements were used to quantify the production of streamwise vorticity and the magnitude of the reorientation term from the vorticity transport equation. The effect of Mach number, pressure gradient, operating voltage, and electrode length was then investigated for the PSVGs. The results indicate that the PSVGs could easily outperform the passive VGs and provide a suitable alternative for flow control.

  12. Passive coherent location system simulation and evaluation

    NASA Astrophysics Data System (ADS)

    Slezák, Libor; Kvasnička, Michael; Pelant, Martin; Vávra, Jiř; Plšek, Radek

    2006-02-01

    Passive Coherent Location (PCL) is going to be important and perspective system of passive location of non cooperative and stealth targets. It works with the sources of irradiation of opportunity. PCL is intended to be a part of mobile Air Command and Control System (ACCS) as a Deployable ACCS Component (DAC). The company ERA works on PCL system parameters verification program by complete PCL simulator development since the year 2003. The Czech DoD takes financial participation on this program. The moving targets scenario, the RCS calculation by method of moment, ground clutter scattering and signal processing method (the bottle neck of the PCL) are available up to now in simulator tool. The digital signal (DSP) processing algorithms are performed both on simulated data and on real data measured at NATO C3 Agency in their Haag experiment. The Institute of Information Theory and Automation of the Academy of Sciences of the Czech Republic takes part on the implementation of the DSP algorithms in FPGA. The paper describes the simulator and signal processing structure and results both on simulated and measured data.

  13. Postural vascular response in human skin: passive and active reactions to alteration of transmural pressure.

    PubMed

    Jepsen, H; Gaehtgens, P

    1993-09-01

    Laser-Doppler (LD) fluxmetry was performed in the palmar finger skin of healthy subjects to study the mechanisms contributing to the postural vascular response. Local transmural pressure in the skin blood vessels of the region studied was altered for 1 min in two experimental series either by passive movement of the arm to different vertical hand positions relative to heart level or by application of external pressure (-120-180 mmHg) to the finger. Heart and respiratory rate, arterial blood pressure, and LD flux in the contralateral finger (kept at heart level) were measured. The measurements suggest a compound reaction of local (myogenic) and systemic (neurogenic) mechanisms: the local regulatory component appears as a graded active vascular response elicited by passive vessel distension or compression. A systemic component, associated with a single deep inspiration, is frequently observed during the actual movement of the arm. In addition, prolonged holding of the test hand in a given vertical position also elicits a delayed vascular response in the control hand at heart level, which may be generated by volume receptors in the intrathoracic low-pressure system.

  14. Implementation of Active Thermal Control (ATC) for the Soil Moisture Active and Passive (SMAP) Radiometer

    NASA Technical Reports Server (NTRS)

    Mikhaylov, Rebecca; Kwack, Eug; French, Richard; Dawson, Douglas; Hoffman, Pamela

    2014-01-01

    NASA's Earth Observing Soil Moisture Active and Passive (SMAP) Mission is scheduled to launch in November 2014 into a 685 kilometer near-polar, sun-synchronous orbit. SMAP will provide comprehensive global mapping measurements of soil moisture and freeze/thaw state in order to enhance understanding of the processes that link the water, energy, and carbon cycles. The primary objectives of SMAP are to improve worldwide weather and flood forecasting, enhance climate prediction, and refine drought and agriculture monitoring during its three year mission. The SMAP instrument architecture incorporates an L-band radar and an L-band radiometer which share a common feed horn and parabolic mesh reflector. The instrument rotates about the nadir axis at approximately 15 revolutions per minute, thereby providing a conically scanning wide swath antenna beam that is capable of achieving global coverage within three days. In order to make the necessary precise surface emission measurements from space, the electronics and hardware associated with the radiometer must meet tight short-term (instantaneous and orbital) and long-term (monthly and mission) thermal stabilities. Maintaining these tight thermal stabilities is quite challenging because the sensitive electronics are located on a fast spinning platform that can either be in full sunlight or total eclipse, thus exposing them to a highly transient environment. A passive design approach was first adopted early in the design cycle as a low-cost solution. With careful thermal design efforts to cocoon and protect all sensitive components, all stability requirements were met passively. Active thermal control (ATC) was later added after the instrument Preliminary Design Review (PDR) to mitigate the threat of undetected gain glitches, not for thermal-stability reasons. Gain glitches are common problems with radiometers during missions, and one simple way to avoid gain glitches is to use the in-flight set point programmability that ATC affords to operate the radiometer component away from the problematic temperature zone. A simple ThermXL model (10 nodes) was developed to exercise quick trade studies among various proposed control algorithms: Modified P control vs. PI control. The ThermXL results were then compared with the detailed Thermal Desktop (TD) model for corroboration. Once done, the simple ThermXL model was used to evaluate parameter effects such as temperature digitization, heater size and gain margin, time step, and voltage variation of power supply on the ATC performance. A Modified P control algorithm was implemented into the instrument flight electronics based on the ThermXL results. The thermal short-term stability margin decreased by 10 percent with ATC and a wide temperature error band (plus or minus 0.1 degrees Centigrade) compared to the original passive thermal design. However, a tighter temperature error band (plus or minus 0.1 degrees Centigrade) increased the thermal short-term stability margin by a factor of three over the passive thermal design. The current ATC design provides robust thermal control, tighter stability, and greater in-flight flexibility even though its implementation was prompted by non-thermal performance concerns.

  15. Adaptive fuzzy control of a class of nonaffine nonlinear system with input saturation based on passivity theorem.

    PubMed

    Molavi, Ali; Jalali, Aliakbar; Ghasemi Naraghi, Mahdi

    2017-07-01

    In this paper, based on the passivity theorem, an adaptive fuzzy controller is designed for a class of unknown nonaffine nonlinear systems with arbitrary relative degree and saturation input nonlinearity to track the desired trajectory. The system equations are in normal form and its unforced dynamic may be unstable. As relative degree one is a structural obstacle in system passivation approach, in this paper, backstepping method is used to circumvent this obstacle and passivate the system step by step. Because of the existence of uncertainty and disturbance in the system, exact passivation and reference tracking cannot be tackled, so the approximate passivation or passivation with respect to a set is obtained to hold the tracking error in a neighborhood around zero. Furthermore, in order to overcome the non-smoothness of the saturation input nonlinearity, a parametric smooth nonlinear function with arbitrary approximation error is used to approximate the input saturation. Finally, the simulation results for the theoretical and practical examples are given to validate the proposed controller. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  16. Inlet Flow Control and Prediction Technologies for Embedded Propulsion Systems

    NASA Technical Reports Server (NTRS)

    McMillan, Michelle L.; Gissen, Abe; Vukasinovic, Bojan; Lakebrink, Matthew T.; Glezer, Ari; Mani, Mori; Mace, James

    2010-01-01

    Fail-safe inlet flow control may enable high-speed cruise efficiency, low noise signature, and reduced fuel-burn goals for hybrid wing-body aircraft. The objectives of this program are to develop flow control and prediction methodologies for boundary-layer ingesting (BLI) inlets used in these aircraft. This report covers the second of a three year program. The approach integrates experiments and numerical simulations. Both passive and active flow-control devices were tested in a small-scale wind tunnel. Hybrid actuation approaches, combining a passive microvane and active synthetic jet, were tested in various geometric arrangements. Detailed flow measurements were taken to provide insight into the flow physics. Results of the numerical simulations were correlated against experimental data. The sensitivity of results to grid resolution and turbulence models was examined. Aerodynamic benefits from microvanes and microramps were assessed when installed in an offset BLI inlet. Benefits were quantified in terms of recovery and distortion changes. Microvanes were more effective than microramps at improving recovery and distortion.

  17. Cigarettes vs. e-cigarettes: Passive exposure at home measured by means of airborne marker and biomarkers.

    PubMed

    Ballbè, Montse; Martínez-Sánchez, Jose M; Sureda, Xisca; Fu, Marcela; Pérez-Ortuño, Raúl; Pascual, José A; Saltó, Esteve; Fernández, Esteve

    2014-11-01

    There is scarce evidence about passive exposure to the vapour released or exhaled from electronic cigarettes (e-cigarettes) under real conditions. The aim of this study is to characterise passive exposure to nicotine from e-cigarettes' vapour and conventional cigarettes' smoke at home among non-smokers under real-use conditions. We conducted an observational study with 54 non-smoker volunteers from different homes: 25 living at home with conventional smokers, 5 living with nicotine e-cigarette users, and 24 from control homes (not using conventional cigarettes neither e-cigarettes). We measured airborne nicotine at home and biomarkers (cotinine in saliva and urine). We calculated geometric mean (GM) and geometric standard deviations (GSD). We also performed ANOVA and Student's t tests for the log-transformed data. We used Bonferroni-corrected t-tests to control the family error rate for multiple comparisons at 5%. The GMs of airborne nicotine were 0.74 μg/m(3) (GSD=4.05) in the smokers' homes, 0.13 μg/m(3) (GSD=2.4) in the e-cigarettes users' homes, and 0.02 μg/m(3) (GSD=3.51) in the control homes. The GMs of salivary cotinine were 0.38 ng/ml (GSD=2.34) in the smokers' homes, 0.19 ng/ml (GSD=2.17) in the e-cigarettes users' homes, and 0.07 ng/ml (GSD=1.79) in the control homes. Salivary cotinine concentrations of the non-smokers exposed to e-cigarette's vapour at home (all exposed ≥ 2 h/day) were statistically significant different that those found in non-smokers exposed to second-hand smoke ≥ 2 h/day and in non-smokers from control homes. The airborne markers were statistically higher in conventional cigarette homes than in e-cigarettes homes (5.7 times higher). However, concentrations of both biomarkers among non-smokers exposed to conventional cigarettes and e-cigarettes' vapour were statistically similar (only 2 and 1.4 times higher, respectively). The levels of airborne nicotine and cotinine concentrations in the homes with e-cigarette users were higher than control homes (differences statistically significant). Our results show that non-smokers passively exposed to e-cigarettes absorb nicotine. Copyright © 2014. Published by Elsevier Inc.

  18. Wireless SAW passive tag temperature measurement in the collision case

    NASA Astrophysics Data System (ADS)

    Sorokin, A.; Shepeta, A.; Wattimena, M.

    2018-04-01

    This paper describes temperature measurement in the multisensor systems based on the radio-frequency identification SAW passive tags which are currently applied in the electric power systems and the switchgears. Different approaches of temperature measurement in the collision case are shown here. The study is based on the tag model with specific topology, which allows us to determine temperature through the response signal with time-frequency information. This research considers the collision case for several passive tags as the temperature sensors which are placed in the switchgear. This research proposal is to analyze the possibility of using several SAW passive sensors in the collision case. We consider the using of the different typical elements for passive surface acoustic wave tag which applies as an anticollision passive sensor. These wireless sensors based on the surface acoustic waves tags contain specifically coded structures. This topology makes possible the reliability of increasing tag identification and the temperature measurement in the collision case. As the results for this case we illustrate simultaneous measurement of at least six sensors.

  19. Semi-active tuned liquid column damper implementation with real-time hybrid simulations

    NASA Astrophysics Data System (ADS)

    Riascos, Carlos; Marulanda Casas, Johannio; Thomson, Peter

    2016-04-01

    Real-time hybrid simulation (RTHS) is a modern cyber-physical technique used for the experimental evaluation of complex systems, that treats the system components with predictable behavior as a numerical substructure and the components that are difficult to model as an experimental substructure. Therefore it is an attractive method for evaluation of the response of civil structures under earthquake, wind and anthropic loads. In this paper, the response of three-story shear frame controlled by a tuned liquid column damper (TLCD) and subject to base excitation is considered. Both passive and semi-active control strategies were implemented and are compared. While the passive TLCD achieved a reduction of 50% in the acceleration response of the main structure in comparison with the structure without control, the semi-active TLCD achieved a reduction of 70%, and was robust to variations in the dynamic properties of the main structure. In addition, a RTHS was implemented with the main structure modeled as a linear, time-invariant (LTI) system through a state space representation and the TLCD, with both control strategies, was evaluated on a shake table that reproduced the displacement of the virtual structure. Current assessment measures for RTHS were used to quantify the performance with parameters such as generalized amplitude, equivalent time delay between the target and measured displacement of the shake table, and energy error using the measured force, and prove that the RTHS described in this paper is an accurate method for the experimental evaluation of structural control systems.

  20. Ammonia Generation and Utilization in a Passive SCR (TWC+SCR) System on Lean Gasoline Engine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prikhodko, Vitaly Y; Parks, II, James E; Pihl, Josh A

    Lean gasoline engines offer greater fuel economy than the common stoichiometric gasoline engine, but the current three-way catalyst (TWC) on stoichiometric engines is unable to control nitrogen oxide (NOX) emissions in the oxygen-rich exhaust. Thus, lean NOX emission control is required to meet existing Tier 2 and upcoming Tier 3 emission regulations set by the U.S. Environmental Protection Agency (EPA). While urea-based selective catalytic reduction (SCR) has proven effective in controlling NOX from diesel engines, the urea storage and delivery components can add significant size and cost. As such, onboard NH3 production via a passive SCR approach is of interest.more » In a passive SCR system, NH3 is generated over a close-coupled TWC during periodic slightly rich engine operation and subsequently stored on an underfloor SCR catalyst. Upon switching to lean operation, NOX passes through the TWC and is reduced by the stored NH3 on the SCR catalyst. In this work, a passive SCR system was evaluated on a 2.0-liter BMW lean burn gasoline direct injection engine to assess NH3 generation over a Pd-only TWC and utilization over a Cu-based SCR catalyst. System NOX reduction efficiency and fuel efficiency improvement compared to stoichiometric engine operation were measured. A feedback control strategy based on cumulative NH3 produced by the TWC during rich operation and NOX emissions during lean operation was implemented on the engine to control lean/rich cycle timing. 15% excess NH3 production over a 1:1 NH3:NOX ratio was required (via longer rich cycle timing) to achieve 99.7% NOX conversion at an SCR average inlet temperature of 350 C. Increasing NH3 generation further resulted in even higher NOX conversion; however, tailpipe NH3 emissions resulted. At higher temperatures, NH3 oxidation becomes important and limits NH3 availability for NOX reduction. At the engine conditions studied here, greater than 99% NOX conversion was achieved with passive SCR while delivering fuel efficiency benefits ranging between 6-11% compared with stoichiometric operation.« less

  1. Effect of scapular stabilization during horizontal adduction stretching on passive internal rotation and posterior shoulder tightness in young women volleyball athletes: a randomized controlled trial.

    PubMed

    Salamh, Paul A; Kolber, Morey J; Hanney, William J

    2015-02-01

    To evaluate the effect of scapular stabilization during horizontal adduction stretching (cross-body) on posterior shoulder tightness (PST) and passive internal rotation (IR). Randomized controlled trial with single blinding. Athletic club. Asymptomatic volleyball players who are women with glenohumeral internal rotation deficit (N=60). Subjects were randomly assigned to either horizontal adduction stretching with manual scapular stabilization (n=30) or horizontal adduction stretching without stabilization (n=30). Passive stretching was performed for 3- to 30-second holds in both groups. Range of motion measurements of PST and IR were performed on the athlete's dominant shoulder prior to and immediately after the intervention. Baseline mean angular measurements of PST and IR for all athletes involved in the study were 62°±14° and 40°±10°, respectively, with no significant difference between groups (P=.598 and P=.734, respectively). Mean PST measurements were significantly different between groups after the horizontal adduction stretch, with a mean angle of 83°±17° among the scapular stabilization group and 65°±13° among the nonstabilization group (P<.001). Measurements of IR were also significantly different between groups, with a mean angle of 51°±14° among the scapular stabilization group and 43°±9° among the nonstabilization group (P=.006). Horizontal adduction stretches performed with scapular stabilization produced significantly greater improvements in IR and PST than horizontal adduction stretching without scapular stabilization. Copyright © 2015 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  2. Plant chlorophyll fluorescence: active and passive measurements at canopy and leaf scales with different nitrogen treatments

    PubMed Central

    Cendrero-Mateo, M. Pilar; Moran, M. Susan; Papuga, Shirley A.; Thorp, K.R.; Alonso, L.; Moreno, J.; Ponce-Campos, G.; Rascher, U.; Wang, G.

    2016-01-01

    Most studies assessing chlorophyll fluorescence (ChlF) have examined leaf responses to environmental stress conditions using active techniques. Alternatively, passive techniques are able to measure ChlF at both leaf and canopy scales. However, the measurement principles of both techniques are different, and only a few datasets concerning the relationships between them are reported in the literature. In this study, we investigated the potential for interchanging ChlF measurements using active techniques with passive measurements at different temporal and spatial scales. The ultimate objective was to determine the limits within which active and passive techniques are comparable. The results presented in this study showed that active and passive measurements were highly correlated over the growing season across nitrogen treatments at both canopy and leaf-average scale. At the single-leaf scale, the seasonal relation between techniques was weaker, but still significant. The variability within single-leaf measurements was largely related to leaf heterogeneity associated with variations in CO2 assimilation and stomatal conductance, and less so to variations in leaf chlorophyll content, leaf size or measurement inputs (e.g. light reflected and emitted by the leaf and illumination conditions and leaf spectrum). This uncertainty was exacerbated when single-leaf analysis was limited to a particular day rather than the entire season. We concluded that daily measurements of active and passive ChlF at the single-leaf scale are not comparable. However, canopy and leaf-average active measurements can be used to better understand the daily and seasonal behaviour of passive ChlF measurements. In turn, this can be used to better estimate plant photosynthetic capacity and therefore to provide improved information for crop management. PMID:26482242

  3. Improved Assessment Strategies for Vapor Intrusion Passive Samplers and Building Pressure Control

    DTIC Science & Technology

    2013-09-01

    pressure control. Matrix Analyte Method Container Holding Time (Days) Vapor Radon McHugh , Hammond, Nickels , and Hartman, 2008 Tedlar ® bag 14...2: Diffusive Sampling,” ISO 16017-2:2003. McHugh T. E., D. E. Hammond, T. Nickels , and B. Hartman. 2008. “Use of Radon Measurements for Evaluation...Control I. D. Rivera-Duarte D. B. Chadwick SSC Pacific T. McAlary H. Groenevelt T. Creamer D. Bertrand Geosyntec Consultants, Inc. T. McHugh

  4. Passivation of pigment particles for thermal control coatings

    NASA Technical Reports Server (NTRS)

    Sancier, K. M.; Morrison, S. R.; Farley, E. P.

    1975-01-01

    The preparation of a matrix of 48 samples consisting of pigments and pigmented paints is described. The results obtained from testing these samples by electron spin resonance and by in situ spectral reflectance measurements in space simulation tests are presented. Conclusions and recommendations for further research are given.

  5. Ankle manual therapy for individuals with post-acute ankle sprains: description of a randomized, placebo-controlled clinical trial.

    PubMed

    Davenport, Todd E; Kulig, Kornelia; Fisher, Beth E

    2010-10-19

    Ankle sprains are common within the general population and can result in prolonged disablement. Limited talocrural dorsiflexion range of motion (DF ROM) is a common consequence of ankle sprain. Limited talocrural DF ROM may contribute to persistent symptoms, disability, and an elevated risk for re-injury. As a result, many health care practitioners use hands-on passive procedures with the intention of improving talocrural joint DF ROM in individuals following ankle sprains. Dosage of passive hands-on procedures involves a continuum of treatment speeds. Recent evidence suggests both slow- and fast-speed treatments may be effective to address disablement following ankle sprains. However, these interventions have yet to be longitudinally compared against a placebo study condition. We developed a randomized, placebo-controlled clinical trial designed to test the hypotheses that hands-on treatment procedures administered to individuals following ankle sprains during the post-acute injury period can improve short-, intermediate-, and long-term disablement, as well as reduce the risk for re-injury. This study is designed to measure the clinical effects of hands-on passive stretching treatment procedures directed to the talocrural joint that vary in treatment speed during the post-acute injury period, compared to hands-on placebo control intervention. http://www.clinicaltrials.gov identifier NCT00888498.

  6. Intrinsic and Extrinsic Contributions to Seated Balance in the Sagittal and Coronal Planes: Implications for Trunk Control After Spinal Cord Injury.

    PubMed

    Audu, Musa L; Triolo, Ronald J

    2015-08-01

    The contributions of intrinsic (passive) and extrinsic (active) properties of the human trunk, in terms of the simultaneous actions about the hip and spinal joints, to the control of sagittal and coronal seated balance were examined. Able-bodied (ABD) and spinal-cord-injured (SCI) volunteers sat on a moving platform which underwent small amplitude perturbations in the anterior-posterior (AP) and medial-lateral (ML) directions while changes to trunk orientation were measured. A linear parametric model that related platform movement to trunk angle was fit to the experimental data by identifying model parameters in the time domain. The results showed that spinal cord injury leads to a systematic reduction in the extrinsic characteristics, while most of the intrinsic characteristics were rarely affected. In both SCI and ABD individuals, passive characteristics alone were not enough to maintain seated balance. Passive stiffness in the ML direction was almost 3 times that in the AP direction, making more extrinsic mechanisms necessary for balance in the latter direction. Proportional and derivative terms of the extrinsic model made the largest contribution to the overall output from the active system, implying that a simple proportional plus derivative (PD) controller structure will suffice for restoring seated balance after spinal cord injury.

  7. Screen time and passive school travel as independent predictors of cardiorespiratory fitness in youth.

    PubMed

    Sandercock, Gavin R H; Ogunleye, Ayodele A

    2012-05-01

    The most prevalent sedentary behaviours in children and adolescents are engagement with small screen media (screen-time) and passive travel (by motorised vehicle). The objective of this research was to assess the independence of these behaviours from one another and from physical activity as predictors of cardiorespiratory fitness in youth. We measured cardiorespiratory fitness in n=6819 10-16 year olds (53% male) who self-reported their physical activity (7-day recall) school travel and screen time habits. Travel was classified as active (walking, cycling) or passive; screen time as <2 h, 2-4 h or >4 h. The multivariate odds of being fit were higher in active travel (Boys: OR 1.32, 95% CI: 1.09-1.59; Girls: OR 1.46, 1.15-1.84) than in passive travel groups. Boys reporting low screen time were more likely to be fit than those reporting >4 h (OR 2.11, 95% CI: 1.68-2.63) as were girls (OR 1.66, 95% CI: 1.24-2.20). These odds remained significant after additionally controlling for physical activity. Passive travel and high screen time are independently associated with poor cardiorespiratory fitness in youth, and this relationship is independent of physical activity levels. A lifestyle involving high screen time and habitual passive school travel appears incompatible with healthful levels of cardiorespiratory fitness in youth. Copyright © 2012 Elsevier Inc. All rights reserved.

  8. Gas-cell measurements for evaluating longwave-infrared passive-sensor performance

    NASA Astrophysics Data System (ADS)

    Cummings, Alan S.; Combs, Roger J.; Thomas, Mark J.; Curry, Timothy; Kroutil, Robert T.

    2006-10-01

    A longwave-infrared (LWIR) passive-spectrometer performance was evaluated with a short-pathlength gas cell. This cell was accurately positioned between the sensor and a NIST-traceable blackbody radiance source. Cell contents were varied over the Beer's Law absorbance range from the limit of detection to saturation for the gas analytes of sulfur hexafluoride and hexafluoroethane. The spectral impact of saturation on infrared absorbance was demonstrated for the passive sensor configuration. The gas-cell contents for all concentration-pathlength products was monitored with an active traditional-laboratory Fourier Transform Infrared (FTIR) spectrometer and was verified by comparison with the established PNNL/DOE vapor-phase infrared (IR) spectral database. For the passive FTIR measurements, the blackbody source employed a range of background temperatures from 5 °C to 50 °C. The passive measurements without the presence of a gas cell permitted a determination of the noise equivalent spectral noise (NESR) for each set of passive gas-cell measurements. In addition, the no-cell condition allowed the evaluation of the effect of gas cell window materials of low density poly(ethylene), potassium chloride, potassium bromide, and zinc selenide. The components of gas cell, different window materials, temperature differentials, and absorbances of target-analyte gases supplied the means of evaluating the LWIR performance of a passive FTIR spectrometer. The various LWIR-passive measurements were found to simulate those often encountered in open-air scenarios important to both industrial and environmental monitoring applications.

  9. Passive exposure to electronic cigarette (e-cigarette) use increases desire for combustible and e-cigarettes in young adult smokers

    PubMed Central

    King, Andrea C; Smith, Lia J; McNamara, Patrick J; Matthews, Alicia K; Fridberg, Daniel J

    2016-01-01

    Background Passive exposure to combustible cigarette use has been shown to act as a cue to increase smoking urge. Given the resemblance of e-cigarettes and other electronic nicotine delivery systems (ENDS) to combustible cigarettes, we examined whether these devices could also act as a cue to increase smoking desire and urges in those passively exposed. Methods Young adult daily smokers (age 18–35 years; N=60) completed subjective ratings before and after exposure to a study confederate drinking bottled water (control cue) and then smoking either a combustible or e-cigarette (active cue). Smoking desire and urge ratings were measured with visual analogue scale items for desire for a regular and an e-cigarette and the Brief Questionnaire of Smoking Urges. Results Passive exposure to both the e-cigarette and combustible cigarette cue significantly increased observers’ ratings of desire and urge to smoke a regular cigarette (all ps<0.05). Exposure to the e-cigarette cue but not the regular cigarette cue also increased desire to smoke an e-cigarette (p<0.01). Conclusions The results provide the first evidence in a controlled setting that electronic cigarette exposure may evoke smoking urges in young adult daily smokers. With replication, these findings may have relevance for ENDS regulation and policy. PMID:24848637

  10. The Role of Motor Learning in Spatial Adaptation near a Tool

    PubMed Central

    Brown, Liana E.; Doole, Robert; Malfait, Nicole

    2011-01-01

    Some visual-tactile (bimodal) cells have visual receptive fields (vRFs) that overlap and extend moderately beyond the skin of the hand. Neurophysiological evidence suggests, however, that a vRF will grow to encompass a hand-held tool following active tool use but not after passive holding. Why does active tool use, and not passive holding, lead to spatial adaptation near a tool? We asked whether spatial adaptation could be the result of motor or visual experience with the tool, and we distinguished between these alternatives by isolating motor from visual experience with the tool. Participants learned to use a novel, weighted tool. The active training group received both motor and visual experience with the tool, the passive training group received visual experience with the tool, but no motor experience, and finally, a no-training control group received neither visual nor motor experience using the tool. After training, we used a cueing paradigm to measure how quickly participants detected targets, varying whether the tool was placed near or far from the target display. Only the active training group detected targets more quickly when the tool was placed near, rather than far, from the target display. This effect of tool location was not present for either the passive-training or control groups. These results suggest that motor learning influences how visual space around the tool is represented. PMID:22174944

  11. Passivity-based sliding mode control for a polytopic stochastic differential inclusion system.

    PubMed

    Liu, Leipo; Fu, Zhumu; Song, Xiaona

    2013-11-01

    Passivity-based sliding mode control for a polytopic stochastic differential inclusion (PSDI) system is considered. A control law is designed such that the reachability of sliding motion is guaranteed. Moreover, sufficient conditions for mean square asymptotic stability and passivity of sliding mode dynamics are obtained by linear matrix inequalities (LMIs). Finally, two examples are given to illustrate the effectiveness of the proposed method. © 2013 ISA. Published by ISA. All rights reserved.

  12. Comparing passive angle-torque curves recorded simultaneously with a load cell versus an isokinetic dynamometer during dorsiflexion stretch tolerance assessments.

    PubMed

    Buckner, Samuel L; Jenkins, Nathaniel D M; Costa, Pablo B; Ryan, Eric D; Herda, Trent J; Cramer, Joel T

    2015-05-01

    The purpose of the present study was to compare the passive angle-torque curves and the passive stiffness (PS, N m °(-)(1)) values recorded simultaneously from a load cell versus an isokinetic dynamometer during dorsiflexion stretch tolerance assessments in vivo. Nine healthy men (mean ± SD age = 21.4 ± 1.6 years) completed stretch tolerance assessments on a custom-built apparatus where passive torque was measured simultaneously from an isokinetic dynamometer and a load cell. Passive torque values that corresponded with the last 10° of dorsiflexion, verified by surface electromyographic amplitude, were analyzed for each device (θ1, θ2, θ3, …, θ10). Passive torque values measured with the load cell were greater (p ≤ 0.05) than the dynamometer torque values for θ4 through θ10. There were more statistical differentiations among joint angles for passive torque measured by the load cell, and the load cell measured a greater (p ≤ 0.01) increase in passive torque and PS than the isokinetic dynamometer. These findings suggested that when examining the angle-torque curves from passive dorsiflexion stretch tolerance tests, a load cell placed under the distal end of the foot may be more sensitive than the torque recorded from an isokinetic dynamometer. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  13. Unsteady aerodynamics of membrane wings with adaptive compliance

    NASA Astrophysics Data System (ADS)

    Kiser, Jillian; Breuer, Kenneth

    2016-11-01

    Membrane wings are known to provide superior aerodynamic performance at low Reynolds numbers (Re =104 -105), primarily due to passive shape adaptation to flow conditions. In addition to this passive deformation, active control of the fluid-structure interaction and resultant aerodynamic properties can be achieved through the use of dielectric elastomer actuators as the wing membrane material. When actuated, membrane pretension is decreased and wing camber increases. Additionally, actuation at resonance frequencies allows additional control over wing camber. We present results using synchronized (i) time-resolved particle image velocimetry (PIV) to resolve the flow field, (ii) 3D direct linear transformation (DLT) to recover membrane shape, (iii) lift/drag/torque measurements and (iv) near-wake hot wire anemometry measurements to characterize the fluid-structure interactions. Particular attention is paid to cases in which the vortex shedding frequency, the membrane resonance, and the actuation frequency coincide. In quantitatively examining both flow field and membrane shape at a range of actuation frequencies and vortex shedding frequencies, this work seeks to find actuation parameters that allow for active control of boundary layer separation over a range of flow conditions. Also at Naval Undersea Warfare Center, Division Newport.

  14. Variable Cadence Walking and Ground Adaptive Standing with a Powered Ankle Prosthesis

    PubMed Central

    Shultz, Amanda H.; Lawson, Brian E.; Goldfarb, Michael

    2015-01-01

    Abstract This paper describes a control approach that provides walking and standing functionality for a powered ankle prosthesis, and demonstrates the efficacy of the approach in experiments in which a unilateral transtibial amputee subject walks with the prosthesis at variable cadences, and stands on various slopes. Both controllers incorporate a finite-state structure that emulates healthy ankle joint behavior via a series of piecewise passive impedance functions. The walking controller incorporates an algorithm to modify impedance parameters based on estimated cadence, while the standing controller incorporates an algorithm to modulate the ankle equilibrium angle in order to adapt to the ground slope and user posture, and the supervisory controller selects between the walking and standing controllers. The system is shown to reproduce several essential biomechanical features of the healthy joint during walking, particularly relative to a passive prosthesis, and is shown to adapt to variable cadences. The system is also shown to adapt to slopes over a range of ± 15 deg and to provide support to the user in a manner that is biomimetic, as validated by quasi-static stiffness measurements recorded by the prosthesis. Data from standing trials indicate that the user places more weight on the powered prosthesis than on his passive prosthesis when standing on sloped surfaces, particularly at angles of 10 deg or greater. The authors also demonstrated that the prosthesis typically began providing support within 1 s of initial contact with the ground. Further, the supervisory controller was shown to be effective in switching between walking and standing, as well as in determining ground slope just prior to the transition from the standing controller to the walking controller, where the estimated ground slope was within 1.25 deg of the actual ground slope for all trials. PMID:25955789

  15. Effects of active, passive and motor imagery paradigms on cerebral and peripheral hemodynamics in older volunteers: a functional TCD study.

    PubMed

    Salinet, Angela S M; Panerai, Ronney B; Robinson, Thompson G

    2012-06-01

    This study aimed to compare the response of metabolic-induced cerebral hemodynamic changes measured using transcranial Doppler (TCD) ultrasonography during passive, active and motor imagery paradigms, and associated peripheral hemodynamic responses. Continuous recordings of bilateral cerebral blood flow velocity (CBFv), blood pressure, heart rate and end-tidal CO(2) were performed in 12 right-handed subjects (aged ≥45 y) before, during and after 60 s of active, passive and mental-imagined paradigms. The results revealed no significant difference in CBFv responses between the paradigms and, furthermore, the temporal patterns of the hemodynamic responses showed some degree of similarity. Moreover, significant changes were seen in cerebral and peripheral hemodynamic responses for all paradigms. Our results suggest that active, passive and motor imagery paradigms can be used interchangeably to assess hemodynamic responses. This will enable more detailed noninvasive assessment in patients, where voluntary movement is not possible, but where abnormalities of cerebral hemodynamic control mechanisms can be anticipated. Copyright © 2012 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  16. Disrupted sensory gating in pathological gambling.

    PubMed

    Stojanov, Wendy; Karayanidis, Frini; Johnston, Patrick; Bailey, Andrew; Carr, Vaughan; Schall, Ulrich

    2003-08-15

    Some neurochemical evidence as well as recent studies on molecular genetics suggest that pathologic gambling may be related to dysregulated dopamine neurotransmission. The current study examined sensory (motor) gating in pathologic gamblers as a putative measure of endogenous brain dopamine activity with prepulse inhibition of the acoustic startle eye-blink response and the auditory P300 event-related potential. Seventeen pathologic gamblers and 21 age- and gender-matched healthy control subjects were assessed. Both prepulse inhibition measures were recorded under passive listening and two-tone prepulse discrimination conditions. Compared to the control group, pathologic gamblers exhibited disrupted sensory (motor) gating on all measures of prepulse inhibition. Sensory motor gating deficits of eye-blink responses were most profound at 120-millisecond prepulse lead intervals in the passive listening task and at 240-millisecond prepulse lead intervals in the two-tone prepulse discrimination task. Sensory gating of P300 was also impaired in pathologic gamblers, particularly at 500-millisecond lead intervals, when performing the discrimination task on the prepulse. In the context of preclinical studies on the disruptive effects of dopamine agonists on prepulse inhibition, our findings suggest increased endogenous brain dopamine activity in pathologic gambling in line with previous neurobiological findings.

  17. Bio-inspired passive actuator simulating an abalone shell mechanism for structural control

    NASA Astrophysics Data System (ADS)

    Yang, Henry T. Y.; Lin, Chun-Hung; Bridges, Daniel; Randall, Connor J.; Hansma, Paul K.

    2010-10-01

    An energy dispersion mechanism called 'sacrificial bonds and hidden length', which is found in some biological systems, such as abalone shells and bones, is the inspiration for new strategies for structural control. Sacrificial bonds and hidden length can substantially increase the stiffness and enhance energy dissipation in the constituent molecules of abalone shells and bone. Having been inspired by the usefulness and effectiveness of such a mechanism, which has evolved over millions of years and countless cycles of evolutions, the authors employ the conceptual underpinnings of this mechanism to develop a bio-inspired passive actuator. This paper presents a fundamental method for optimally designing such bio-inspired passive actuators for structural control. To optimize the bio-inspired passive actuator, a simple method utilizing the force-displacement-velocity (FDV) plots based on LQR control is proposed. A linear regression approach is adopted in this research to find the initial values of the desired parameters for the bio-inspired passive actuator. The illustrative examples, conducted by numerical simulation with experimental validation, suggest that the bio-inspired passive actuator based on sacrificial bonds and hidden length may be comparable in performance to state-of-the-art semi-active actuators.

  18. Method and system to perform energy-extraction based active noise control

    NASA Technical Reports Server (NTRS)

    Kelkar, Atul (Inventor); Joshi, Suresh M. (Inventor)

    2009-01-01

    A method to provide active noise control to reduce noise and vibration in reverberant acoustic enclosures such as aircraft, vehicles, appliances, instruments, industrial equipment and the like is presented. A continuous-time multi-input multi-output (MIMO) state space mathematical model of the plant is obtained via analytical modeling and system identification. Compensation is designed to render the mathematical model passive in the sense of mathematical system theory. The compensated system is checked to ensure robustness of the passive property of the plant. The check ensures that the passivity is preserved if the mathematical model parameters are perturbed from nominal values. A passivity-based controller is designed and verified using numerical simulations and then tested. The controller is designed so that the resulting closed-loop response shows the desired noise reduction.

  19. Methodology for the passive control of orbital inclination and mean local time to meet sun-synchronous orbit requirements

    NASA Technical Reports Server (NTRS)

    Folta, David; Kraft, Lauri

    1992-01-01

    The mean local time (MLT) of equatorial crossing of a sun-synchronous Earth-observing spacecraft orbit drifts with inclination; therefore, in order to maintain the MLT, the inclination must be controlled. Inclination may be maintained actively by costly out-of-plane maneuvers or passively by using the perturbing forces due to the sun and moon. This paper examines the passive control approach using the Earth Observing System (EOS) as a basis for the discussion. Applications to Landsat and National Oceanic and Atmospheric Administration (NOAA) spacecraft are presented for comparison. This technique is especially beneficial to spacecraft lacking propulsion systems. The results indicate that passive inclination control appears to be the preferable maintenance method when spacecraft weight restrictions, operational considerations, and scientific requirements apply.

  20. Semi Active Control of Civil Structures, Analytical and Numerical Studies

    NASA Astrophysics Data System (ADS)

    Kerboua, M.; Benguediab, M.; Megnounif, A.; Benrahou, K. H.; Kaoulala, F.

    Structural control for civil structures was born out of a need to provide safer and more efficient designs with the reality of limited resources. The purpose of structural control is to absorb and to reflect the energy introduced by dynamic loads such as winds, waves, earthquakes, and traffic. Today, the protection of civil structures from severe dynamic loading is typically achieved by allowing the structures to be damaged. Semi-active control devices, also called "smart" control devices, assume the positive aspects of both the passive and active control devices. A semi-active control strategy is similar to the active control strategy. Only here, the control actuator does not directly apply force to the structure, but instead it is used to control the properties of a passive energy device, a controllable passive damper. Semi-active control strategies can be used in many of the same civil applications as passive and active control. One method of operating smart cable dampers is in a purely passive capacity, supplying the dampers with constant optimal voltage. The advantages to this strategy are the relative simplicity of implementing the control strategy as compared to a smart or active control strategy and that the dampers are more easily optimally tuned in- place, eliminating the need to have passive dampers with unique optimal damping coefficients. This research investigated semi-active control of civil structures for natural hazard mitigation. The research has two components, the seismic protection of buildings and the mitigation of wind-induced vibration in structures. An ideal semi-active motion equation of a composite beam that consists of a cantilever beam bonded with a PZT patch using Hamilton's principle and Galerkin's method was treated. A series R-L and a parallel R-L shunt circuits are coupled into the motion equation respectively by means of the constitutive relation of piezoelectric material and Kirchhoff's law to control the beam vibration. A numerical example of the parallel R-L piezoelectric vibration shunt control simulated with MATLAB® is presented. An analytical study of the resistor-inductor (R-L) passive piezoelectric vibration shunt control of a cantilever beam was undertaken. The modal and strain analyses were performed by varying the material properties and geometric configurations of the piezoelectric transducer in relation to the structure in order to maximize the mechanical strain produced in the piezoelectric transducer.

  1. Sciatic nerve stiffness is not changed immediately after a slump neurodynamics technique.

    PubMed

    Neto, Tiago; Freitas, Sandro R; Andrade, Ricardo J; Gomes, João; Vaz, João; Mendes, Bruno; Firmino, Telmo; Nordez, Antoine; Oliveira, Raúl

    2017-01-01

    Neurodynamics techniques aim to assess and improve neural mechanosensitivity. However, there is no in vivo evidence regarding the mechanical effects of these techniques in the nerve stiffness. This study examined the immediate effects of a slump neurodynamics technique in the sciatic nerve shear wave velocity (SWV. i.e. an index of stiffness) using ultrasound-based elastography. Fourteen healthy participants were included in this experiment. Sciatic SWV and ankle passive torque were measured during a passive ankle dorsiflexion motion (2°/s), before and immediately after 3 minutes of slump neurodynamics technique, randomly applied to one lower limb. The contralateral limb served as control. The slump intervention did not change the sciatic SWV (P=0.78), nor the dorsiflexion passive torque (P=0.14), throughout the ankle dorsiflexion motion. Excellent values of intra-rater repeatability (ICC=0.88, 0.68-0.96), and low values of standard error of measurement (0.59 m/s, 0.35-1.15m/s), were observed for the SWV measurements. The sciatic nerve stiffness of healthy participants did not change immediately after a slump neurodynamics technique, suggesting a compliance of the neural tissue to tensile loads. However, these results ought to be confirmed using other neurodynamics techniques and in other populations (e.g. peripheral neuropathies). III.

  2. Microrobot with passive diamagnetic levitation for microparticle manipulations

    NASA Astrophysics Data System (ADS)

    Feng, Lin; Zhang, Shengyuan; Jiang, Yonggang; Zhang, Deyuan; Arai, Fumihito

    2017-12-01

    In this paper, an innovative microrobot with passive diamagnetic levitation is presented. Based on theoretical analysis, finite element method simulation, and experiments, the shape of pyrolytic graphite is redesigned, which improves the stability of passive diamagnetic levitation significantly. Therefore, passive diamagnetic levitation is able to be applied for 3-D control of the microrobot. Compared with the traditional microrobots driven by permanent magnets in a microfluidic chip, the microrobot made of pyrolytic graphite and driven by magnetic force has two advantages, no friction and 3-D control, which is able to expand the scope of the microrobot applications. Finally, the microrobot with passive diamagnetic levitation was demonstrated by being encapsulated in a microfluidic chip for microparticle manipulations.

  3. Physics validation for design change of KSTAR passive stabilizer

    NASA Astrophysics Data System (ADS)

    Jeon, Y. M.; Kim, J. Y.; Oh, Y. K.; Yang, H. L.; Kim, W. C.; Kim, H. K.; Sabbagh, S. A.; Bialek, J. M.; Humphreys, D. A.; Welander, A. S.; Walker, M. L.

    2009-11-01

    Recently, the design of the passive stabilizer in KSTAR has been changed to improve controllability of the active control system and reduce the possibility of producing an additional error field. Originally the passive stabilizer in KSTAR was designed for RWM and vertical instability (or VDE) stabilizations and plasma startup efficiency, so that current bridges were designed and combined through 3D saddle-loop connections. Since the key design change is removing the current bridges, it's essential to assure satisfactory control performance for these instabilities under the design change. Control capability for n=1 RWM and achievable βN will be addressed as a primary goal of the passive stabilizer together with vertical instability control and effects on plasma startup. In addition, the changes in electro-magnetic force on conducting structures will be discussed qualitatively as a key engineering issue of the design change.

  4. Self- and other-agency in people with passivity (first rank) symptoms in schizophrenia.

    PubMed

    Graham-Schmidt, Kyran T; Martin-Iverson, Mathew T; Waters, Flavie A V

    2018-02-01

    Individuals with passivity (first-rank) symptoms report that their actions, thoughts and sensations are influenced or controlled by an external (non-self) agent. Passivity symptoms are closely linked to schizophrenia and related disorders yet they remain poorly understood. One dominant framework posits a role for deficits in the sense of agency. An important question is whether deficits in self-agency can be differentiated from other-agency in schizophrenia and passivity symptoms. This study aimed to evaluate self- and other-agency in 51 people with schizophrenia (n=20 current, 10 past, 21 no history of passivity symptoms), and 48 healthy controls. Participants completed the projected hand illusion (PHI) with active and passive movements, as well as immediate and delayed visual feedback. Experiences of agency and loss of agency over the participant's hand and the image ('the other hand') were assessed with a self-report questionnaire. Those with passivity symptoms (current and past) reported less difference in agency between active and passive movements on items assessing agency over their own hand (but not agency over the other hand). Relative to the healthy controls, the current and never groups continued to experience the illusion with delayed visual feedback suggesting impaired timing mechanisms regardless of symptom profile. These findings are consistent with a reduced contribution of proprioceptive predictive cues to agency judgements specific to self representations in people with passivity symptoms, and a subsequent reliance on external visual cues in these judgements. Altogether, these findings emphasise the multifactorial nature of agency and the contribution of multiple impairments to passivity symptoms. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Reliability of dynamometric passive properties of the pelvic floor muscles in postmenopausal women with stress urinary incontinence.

    PubMed

    Morin, Mélanie; Gravel, Denis; Bourbonnais, Daniel; Dumoulin, Chantale; Ouellet, Stéphane

    2008-01-01

    The passive properties of the pelvic floor muscles (PFM) might play a role in stress urinary incontinence (SUI) pathophysiology. To investigate the test-retest reliability of the dynamometric passive properties of the PFM in postmenopausal SUI women. Thirty-two SUI postmenopausal women were convened to two sessions 2 weeks apart. In each session, the measurements were repeated twice. The pelvic floor musculature was evaluated in four different conditions: (1) forces recorded at minimal aperture (initial passive resistance); (2) passive resistance at maximal aperture; (3) five lengthening and shortening cycles (Forces and passive elastic stiffness (PES) were evaluated at different vaginal apertures. Hysteresis was also calculated.); (4) Percentage of passive resistance loss after 1 min of sustained stretching was computed. The generalizability theory was used to calculate two reliability estimates, the dependability indices (Phi) and the standard error of measurement (SEM), for one session involving one measurement or the mean of two measurements. Overall, the reliability of the passive properties was good with indices of dependability of 0.75-0.93. The SEMs for forces and PES were 0.24-0.67 N and 0.03-0.10 N/mm, respectively, for mean, maximal and 20-mm apertures, representing an error between 13% and 23%. Passive forces at minimal aperture showed lower reliability (Phi = 0.51-0.57) compared with other vaginal openings. The aperture at a common force of 0.5 N was the only parameter demonstrating a poor reliability (Phi = 0.35). This new approach for assessing PFM passive properties showed enough reliability for highly recommending its inclusion in the PFM assessment of SUI postmenopausal women. (c) 2008 Wiley-Liss, Inc.

  6. Orion Passive Thermal: Control Overview

    NASA Technical Reports Server (NTRS)

    Alvarez-Hermandez, Angel; Miller, Stephen W.

    2009-01-01

    A general overview of the NASA Orion Passive Thermal Control System (PTCS) is presented. The topics include: 1) Orion in CxP Hierarchy; 2) General Orion Description/Orientation; and 3) Orion PTCS Overview.

  7. Attenuation of muscle damage by preconditioning with muscle hyperthermia 1-day prior to eccentric exercise.

    PubMed

    Nosaka, K; Muthalib, M; Lavender, A; Laursen, P B

    2007-01-01

    This study investigated the hypothesis that muscle damage would be attenuated in muscles subjected to passive hyperthermia 1 day prior to exercise. Fifteen male students performed 24 maximal eccentric actions of the elbow flexors with one arm; the opposite arm performed the same exercise 2-4 weeks later. The elbow flexors of one arm received a microwave diathermy treatment that increased muscle temperature to over 40 degrees C, 16-20 h prior to the exercise. The contralateral arm acted as an untreated control. Maximal voluntary isometric contraction strength (MVC), range of motion (ROM), upper arm circumference, muscle soreness, plasma creatine kinase activity and myoglobin concentration were measured 1 day prior to exercise, immediately before and after exercise, and daily for 4 days following exercise. Changes in the criterion measures were compared between conditions (treatment vs. control) using a two-way repeated measures ANOVA with a significance level of P < 0.05. All measures changed significantly following exercise, but the treatment arm showed a significantly faster recovery of MVC, a smaller change in ROM, and less muscle soreness compared with the control arm. However, the protective effect conferred by the diathermy treatment was significantly less effective compared with that seen in the second bout performed 4-6 weeks after the initial bout by a subgroup of the subjects (n = 11) using the control arm. These results suggest that passive hyperthermia treatment 1 day prior to eccentric exercise-induced muscle damage has a prophylactic effect, but the effect is not as strong as the repeated bout effect.

  8. A mathematical model of an active control landing gear for load control during impact and roll-out

    NASA Technical Reports Server (NTRS)

    Mcgehee, J. R.; Carden, H. D.

    1976-01-01

    A mathematical model of an active control landing gear (ACOLAG) was developed and programmed for operation on a digital computer. The mathematical model includes theoretical subsonic aerodynamics; first-mode wing bending and torsional characteristics; oleo-pneumatic shock strut with fit and binding friction; closed-loop, series-hydraulic control; empirical tire force-deflection characteristics; antiskid braking; and sinusoidal or random runway roughness. The mathematical model was used to compute the loads and motions for a simulated vertical drop test and a simulated landing impact of a conventional (passive) main landing gear designed for a 2268-kg (5000-lbm) class airplane. Computations were also made for a simply modified version of the passive gear including a series-hydraulic active control system. Comparison of computed results for the passive gear with experimental data shows that the active control landing gear analysis is valid for predicting the loads and motions of an airplane during a symmetrical landing. Computed results for the series-hydraulic active control in conjunction with the simply modified passive gear show that 20- to 30-percent reductions in wing force, relative to those occurring with the modified passive gear, can be obtained during the impact phase of the landing. These reductions in wing force could result in substantial increases in fatigue life of the structure.

  9. Effects of hamstring stretching on passive muscle stiffness vary between hip flexion and knee extension maneuvers.

    PubMed

    Miyamoto, N; Hirata, K; Kanehisa, H

    2017-01-01

    The purpose of this study was to examine whether the effects of hamstring stretching on the passive stiffness of each of the long head of the biceps femoris (BFl), semitendinosus (ST), and semimembranosus (SM) vary between passive knee extension and hip flexion stretching maneuvers. In 12 male subjects, before and after five sets of 90 s static stretching, passive lengthening measurements where knee or hip joint was passively rotated to the maximal range of motion (ROM) were performed. During the passive lengthening, shear modulus of each muscle was measured by ultrasound shear wave elastography. Both stretching maneuvers significantly increased maximal ROM and decreased passive torque at a given joint angle. Passive knee extension stretching maneuver significantly reduced shear modulus at a given knee joint angle in all of BFl, ST, and SM. In contrast, the stretching effect by passive hip flexion maneuver was significant only in ST and SM. The present findings indicate that the effects of hamstring stretching on individual passive muscles' stiffness vary between passive knee extension and hip flexion stretching maneuvers. In terms of reducing the muscle stiffness of BFl, stretching of the hamstring should be performed by passive knee extension rather than hip flexion. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. General Aviation Interior Noise. Part 2; In-Flight Source/Verification

    NASA Technical Reports Server (NTRS)

    Unruh, James F.; Till, Paul D.; Palumbo, Daniel L. (Technical Monitor)

    2002-01-01

    The technical approach made use of the Cessna Model 182E aircraft used in the previous effort as a test bed for noise control application. The present phase of the project reports on flight test results during application of various passive noise treatments in an attempt to verify the noise sources and paths for the aircraft. The data presented establishes the level of interior noise control that can be expected for various passive noise control applications within the aircraft cabin. Subsequent testing will address specific testing to demonstrate the technology available to meet a specified level of noise control by application of passive and/or active noise control technology.

  11. Control of Combustion-Instabilities Through Various Passive Devices

    NASA Technical Reports Server (NTRS)

    Frendi, Abdelkader; Nesman, Tom; Canabal, Francisco

    2005-01-01

    Results of a computational study on the effectiveness of various passive devices for the control of combustion instabilities are presented. An axi-symmetric combustion chamber is considered. The passive control devices investigated are, baffles, Helmholtz resonators and quarter-waves. The results show that a Helmholtz resonator with a smooth orifice achieves the best control results, while a baffle is the least effective for the frequency tested. At high sound pressure levels, the Helmholtz resonator is less effective. It is also found that for a quarter wave, the smoothness of the orifice has the opposite effect than the Helmholtz resonator, i.e. results in less control.

  12. Passive dynamics is a good basis for robot design and control, not!

    NASA Astrophysics Data System (ADS)

    Ruina, Andy

    Many airplanes can, or nearly can, glide stably without control. So, it seems natural that the first successful powered flight followed from mastery of gliding. Many bicycles can, or nearly can, balance themselves when in motion. Bicycle design seems to have evolved to gain this feature. Also, we can make toys and 'robots' that, like a stable glider or coasting bicycle, stably walk without motors or control in a remarkably human-like way. Again, it seems to make sense to use `passive-dynamics' as a core for developing the control of walking robots and to gain understanding of the control of walking people. That's what I used to think. But, so far, this has not led to robust walking robots. What about human evolution? We didn't evolve dynamic bodies and then learn to control them. Rather, people had elaborate control systems way back when we were fish and even worms. However: if control is paramount, why is it that uncontrolled passive-dynamic walkers walk so much like humans? It seems that energy optimal, yet robust, control, perhaps a proxy for evolutionary development, arrives at solutions that have some features in common with passive-dynamics. Rather than thinking of good powered walking as passive walking with a small amount of control added, I now think of good powered walking, human or robotic, as highly controlled, while optimized for, in part, minimal actuator use. Thus, much of the motor effort, always at the ready, is usually titrated out.

  13. Wind-tunnel evaluation of NASA developed control laws for flutter suppression on a DC-10 derivative wing

    NASA Technical Reports Server (NTRS)

    Abel, I.; Newsom, J. R.

    1981-01-01

    Two flutter suppression control laws were synthesized, implemented, and tested on a low speed aeroelastic wing model of a DC-10 derivative. The methodology used to design the control laws is described. Both control laws demonstrated increases in flutter speed in excess of 25 percent above the passive wing flutter speed. The effect of variations in gain and phase on the closed loop performance was measured and compared with analytical predictions. The analytical results are in good agreement with experimental data.

  14. A Review of International Space Station Habitable Element Equipment Offgassing Characteristics

    NASA Technical Reports Server (NTRS)

    Perry, Jay L.

    2010-01-01

    Crewed spacecraft trace contaminant control employs both passive and active methods to achieve acceptable cabin atmospheric quality. Passive methods include carefully selecting materials of construction, employing clean manufacturing practices, and minimizing systems and payload operational impacts to the cabin environment. Materials selection and manufacturing processes constitute the first level of equipment offgassing control. An element-level equipment offgassing test provides preflight verification that passive controls have been successful. Offgassing test results from multiple International Space Station (ISS) habitable elements and cargo vehicles are summarized and implications for active contamination control equipment design are discussed

  15. Identifying genetic loci controlling neonatal passive transfer of immunity using a hybrid genotyping strategy

    USDA-ARS?s Scientific Manuscript database

    Colostrum intake is critical to a piglet’s survival and can be measured by precipitating out the gamma-immunoglobulins from serum with ammonium sulfate (immunocrit). Genetic analysis of immunocrits on 5,312 piglets indicated that the heritabilities (se) for direct and maternal effects were 0.13(0.06...

  16. Passive stiffness of rat skeletal muscle undernourished during fetal development

    PubMed Central

    Toscano, Ana Elisa; Ferraz, Karla Mônica; de Castro, Raul Manhães; Canon, Francis

    2010-01-01

    OBJECTIVES: The aim of the study was to investigate the effect of fetal undernutrition on the passive mechanical properties of skeletal muscle of weaned and young adult rats. INTRODUCTION: A poor nutrition supply during fetal development affects physiological functions of the fetus. From a mechanical point of view, skeletal muscle can be also characterized by its resistance to passive stretch. METHODS: Male Wistar rats were divided into two groups according to their mother's diet during pregnancy: a control group (mothers fed a 17% protein diet) and an isocaloric low‐protein group (mothers fed a 7.8% protein diet). At birth, all mothers received a standardized meal ad libitum. At the age of 25 and 90 days, the soleus muscle and extensor digitorum longus (EDL) muscles were removed in order to test the passive mechanical properties. A first mechanical test consisted of an incremental stepwise extension test using fast velocity stretching (500 mm/s) enabling us to measure, for each extension stepwise, the dynamic stress (σd) and the steady stress (σs). A second test consisted of a slow velocity stretch in order to calculate normalized stiffness and tangent modulus from the stress–strain relationship. RESULTS: The results for the mechanical properties showed an important increase in passive stiffness in both the soleus and EDL muscles in weaned rat. In contrast, no modification was observed in young adult rats. CONCLUSIONS: The increase in passive stiffness in skeletal muscle of weaned rat submitted to intrauterine undernutrition it is most likely due to changes in muscle passive stiffness. PMID:21340228

  17. Influence of Passive Joint Stiffness on Proprioceptive Acuity in Individuals With Functional Instability of the Ankle.

    PubMed

    Marinho, Hellen Veloso Rocha; Amaral, Giovanna Mendes; de Souza Moreira, Bruno; Araújo, Vanessa Lara; Souza, Thales Rezende; Ocarino, Juliana Melo; da Fonseca, Sérgio Teixeira

    2017-12-01

    Study Design Controlled laboratory study, cross-sectional. Background Deficits in ankle proprioceptive acuity have been reported in persons with functional instability of the ankle. Passive stiffness has been proposed as a possible mechanism underlying proprioceptive acuity. Objective To compare proprioceptive acuity and passive ankle stiffness in persons with and without functional ankle instability, and to assess the influence of passive joint stiffness on proprioceptive acuity in persons with functional ankle instability. Methods A sample of 18 subjects with and 18 without complaints of functional ankle instability following lateral ankle sprain participated. An isokinetic dynamometer was used to compare motion perception threshold, passive position sense, and passive ankle stiffness between groups. To evaluate the influence of passive stiffness on proprioceptive acuity, individuals in the lateral functional ankle instability group were divided into 2 subgroups: "high" and "low" passive ankle stiffness. Results The functional ankle instability group exhibited increased motion perception threshold when compared with the corresponding limb of the control group. Between-group differences were not found for passive position sense and passive ankle stiffness. Those in the functional ankle instability group with higher passive ankle stiffness had smaller motion perception thresholds than those with lower passive ankle stiffness. Conclusion Unlike motion perception threshold, passive position sense is not affected by the presence of functional ankle instability. Passive ankle stiffness appears to influence proprioceptive acuity in persons with functional ankle instability. J Orthop Sports Phys Ther 2017;47(12):899-905. Epub 7 Oct 2017. doi:10.2519/jospt.2017.7030.

  18. Response to a combination of oxygen and a hypnotic as treatment for obstructive sleep apnoea is predicted by a patient's therapeutic CPAP requirement.

    PubMed

    Landry, Shane A; Joosten, Simon A; Sands, Scott A; White, David P; Malhotra, Atul; Wellman, Andrew; Hamilton, Garun S; Edwards, Bradley A

    2017-08-01

    Upper airway collapsibility predicts the response to several non-continuous positive airway pressure (CPAP) interventions for obstructive sleep apnoea (OSA). Measures of upper airway collapsibility cannot be easily performed in a clinical context; however, a patient's therapeutic CPAP requirement may serve as a surrogate measure of collapsibility. The present work aimed to compare the predictive use of CPAP level with detailed physiological measures of collapsibility. Therapeutic CPAP levels and gold-standard pharyngeal collapsibility measures (passive pharyngeal critical closing pressure (P crit ) and ventilation at CPAP level of 0 cmH 2 O (V passive )) were retrospectively analysed from a randomized controlled trial (n = 20) comparing the combination of oxygen and eszopiclone (treatment) versus placebo/air control. Responders (9/20) to treatment were defined as those who exhibited a 50% reduction in apnoea/hypopnoea index (AHI) plus an AHI<15 events/h on-therapy. Responders to treatment had a lower therapeutic CPAP requirement compared with non-responders (6.6 (5.4-8.1)  cmH 2 O vs 8.9 (8.4-10.4) cmH 2 O, P = 0.007), consistent with their reduced collapsibility (lower P crit , P = 0.017, higher V passive P = 0.025). Therapeutic CPAP level provided the highest predictive accuracy for differentiating responders from non-responders (area under the curve (AUC) = 0.86 ± 0.9, 95% CI: 0.68-1.00, P = 0.007). However, both P crit (AUC = 0.83 ± 0.11, 95% CI: 0.62-1.00, P = 0.017) and V passive (AUC = 0.77 ± 0.12, 95% CI: 0.53-1.00, P = 0.44) performed well, and the difference in AUC for these three metrics was not statistically different. A therapeutic CPAP level ≤8 cmH 2 O provided 78% sensitivity and 82% specificity (positive predictive value = 78%, negative predictive value = 82%) for predicting a response to these therapies. Therapeutic CPAP requirement, as a surrogate measure of pharyngeal collapsibility, predicts the response to non-anatomical therapy (oxygen and eszopiclone) for OSA. © 2017 Asian Pacific Society of Respirology.

  19. Extensibility of the hamstrings is best explained by mechanical components of muscle contraction, not behavioral measures in individuals with chronic low back pain.

    PubMed

    Marshall, Paul W M; Mannion, Jamie; Murphy, Bernadette A

    2009-08-01

    To examine the relationship between hamstring extensibility by use of the instrumented straight leg raise; mechanical components of muscle contraction, including muscle recruitment, passive torque measures of tissue stiffness, and eccentric strength; and self-reported measures of pain and disability. Cross-sectional study. University laboratory. Twenty-one individuals with chronic nonspecific axial lower back pain and 15 healthy control subjects. Instrumented straight leg raise, concentric and eccentric hamstring strength, self-reported measures of pain, disability, fear avoidance, general health and well-being Objective measures included hamstring extensibility, hamstring muscle stiffness, absolute and relative concentric/eccentric strength, concentric/eccentric strength ratios. Self-reported measures included Oswestry disability index, visual analog pain scale, fear avoidance beliefs, and general health and well being. Patients with lower back pain had lower range of motion, greater changes in muscle stiffness, and impaired concentric-to-eccentric strength levels. Stepwise regression identified measures of stiffness as significantly predicting hamstring extensibility (adjusted r(2) = 0.58, F = 23.76, P < .001). Self-reported measures were not associated with extensibility. Gender differences were noted for passive stiffness and absolute strength. For women, later onset of the medial hamstrings also was associated with greater hamstring extensibility. Decreased extensibility of the hamstrings was associated with increased passive stiffness during the common range of motion (20 to 50 degrees ). Impaired stretch tolerance is associated with actual mechanical restriction, not behavioral measures indicating increased pain or fear-avoidant behavior. With no relationship to actual disability and contradictory findings in the literature for the relationship of the hamstrings to the mechanics of the low back, it is unclear whether decreased hamstring extensibility should be targeted in rehabilitation programs for axial lower back pain.

  20. Afferent and Efferent Aspects of Mandibular Sensorimotor Control in Adults who Stutter

    PubMed Central

    Daliri, Ayoub; Prokopenko, Roman A.; Max, Ludo

    2013-01-01

    Purpose Individuals who stutter show sensorimotor deficiencies in speech and nonspeech movements. For the mandibular system, we dissociated the sense of kinesthesia from the efferent control component to examine whether kinesthetic integrity itself is compromised in stuttering or whether deficiencies occur only when generating motor commands. Method We investigated 11 stuttering and 11 nonstuttering adults’ kinesthetic sensitivity threshold and kinesthetic accuracy for passive jaw movements as well as their minimal displacement threshold and positioning accuracy for active jaw movements. We also investigated the correlation with an anatomical index of jaw size. Results The groups showed no statistically significant differences on sensory measures for passive jaw movements. Although some stuttering individuals performed more poorly than any nonstuttering participants on the active movement tasks, between-group differences for active movements were also not statistically significant. Unlike fluent speakers, however, the stuttering group showed a statistically significant correlation between mandibular size and performance in the active and passive near-threshold tasks. Conclusions Previously reported minimal movement differences were not replicated. Instead, stuttering individuals’ performance varied with anatomical properties. These correlational results are consistent with the hypothesis that stuttering participants generate and perceive movements based on less accurate internal models of the involved neuromechanical systems. PMID:23816664

  1. Sustained Cutaneous Vasoconstriction during and Following Cyrotherapy Treatment: Role of Oxidative Stress and Rho Kinase

    PubMed Central

    Christmas, Kevin M.; Patik, Jordan C.; Khoshnevis, Sepideh; Diller, Kenneth R.; Brothers, R. Matthew

    2016-01-01

    Cryotherapy is a therapeutic technique using ice or cold water applied to the skin to reduce bleeding, inflammation, pain, and swelling following soft tissue trauma and injury. While beneficial, there are some side effects such as pronounced vasoconstriction and tissue ischemia that are sustained for hours post-treatment. This study tested the hypothesis that this vasoconstriction is mediated by 1) the Rho-kinase pathway and/or 2) elevated oxidative stress. 9 subjects were fitted with a commercially available cryotherapy unit with a water perfused bladder on the lateral portion of the right calf. Participants were instrumented with three microdialysis probes underneath the bladder. One site received lactated ringers (control site), one received the Rho-Kinase inhibitor Fasudil, and one received Ascorbic Acid. Skin temperature (Tskin) and cutaneous vascular conductance (CVC) was measured at each site. Subjects had 1 °C water perfused through the bladder for 30 min, followed by passive rewarming for 90 min. Tskin fell from ~ 34 °C to ~ 18.0 °C during active cooling across all sites and this response was similar for all sites (P>0.05 for all comparisons). During passive rewarming Tskin rose to a similar degree in all sites (P>0.05 relative to the end of cooling). %CVC was reduced during active cooling in all sites; however, the magnitude of this response was blunted in the Fasudil site relative to control (P<0.001 for all comparisons) and min 25 and 30 of cooling in the Ascorbic Acid site (P<0.05). During passive rewarming %CVC at the control and Ascorbic Acid sites did not change such that values were similar to the end of cooling (P>0.05 for each comparison). %CVC at the Fasudil site remained elevated during passive rewarming such that values were higher compared to the control and Ascorbic Acid sites throughout the 90 min of passive rewarming (P<0.001 main effect of Fasudi). These findings indicate that the Rho-kinase pathway contributes to pronounced vasoconstriction during cryotherapy as well as the sustained vasoconstriction during the subsequent rewarming period post treatment. PMID:27089823

  2. The Effects of Interactive and Passive Distraction on Cold Pressor Pain in Preschool-aged Children

    PubMed Central

    Dahlquist, Lynnda M.; Wohlheiter, Karen

    2011-01-01

    Objective Using a mixed model design, this study examined the effects of interactive versus passive distraction on healthy preschool-aged children’s cold pressor pain tolerance. Methods Sixty-one children aged 3–5 years were randomly assigned to one of the following: interactive distraction, passive distraction, or no distraction control. Participants underwent a baseline cold pressor trial followed by interactive distraction trial, passive distraction trial, or second baseline trial. One or two additional trials followed. Children originally assigned to distraction received the alternate distraction intervention. Controls participated in both interactive and passive distraction trials in counterbalanced order. Results Participants showed significantly higher pain tolerance during both interactive and passive distraction relative to baseline. The two distraction conditions did not differ. Conclusions Interactive and passive video game distraction appear to be effective for preschool-aged children during laboratory pain exposure. Future studies should examine whether more extensive training would enhance effects of interactive video game distraction. PMID:21278378

  3. Electronic properties of Al xGa 1- xAs surface passivated by ultrathin silicon interface control layer

    NASA Astrophysics Data System (ADS)

    Adamowicz, B.; Miczek, M.; Ikeya, K.; Mutoh, M.; Saitoh, T.; Fujikura, H.; Hasegawa, H.

    1999-03-01

    The photoluminescence surface state spectroscopy (PLS 3) method was applied to a study of the surface state distribution ( NSS), effective surface recombination velocity ( Seff), electron ( EFn) and hole ( EFp) quasi-Fermi levels and band bending ( VS) on the Al 0.33Ga 0.67As surface air-exposed and passivated by the Si interface control layer (ICL) technique. Using the detailed measurements of the PL quantum efficiency for different excitation intensities, combined with the rigorous computer simulations of the bulk and surface recombination processes, the behavior and correlation among the surface characteristics under photo-excitation was determined. The present analysis indicated that forming of a Si 3N 4/Si ICL double layer (with a monolayer level control) on AlGaAs surface reduces the minimum interface state density down to 10 10 cm -2 eV -1 and surface recombination velocity to the range of 10 4 cm/s under low excitations.

  4. Passive Smoking and Breast Cancer Risk among Non-Smoking Women: A Case-Control Study in China.

    PubMed

    Li, Bin; Wang, Lian; Lu, Min-Shan; Mo, Xiong-Fei; Lin, Fang-Yu; Ho, Suzanne C; Zhang, Cai-Xia

    2015-01-01

    The role of passive smoking on breast cancer risk was unclear. This study aimed to evaluate the association between passive smoking and breast cancer risk among Chinese women. A hospital-based case-control study, including 877 breast cancer cases and 890 controls, frequency-matched by age and residence, was conducted. A structured questionnaire was used to collect information on passive smoking history through face-to-face interview by trained interviewers. Unconditional logistic regression models were used to estimate the association between passive smoking and breast cancer risk. A positive association between any passive smoking exposure and breast cancer risk was observed. Compared with women who were never exposed to passive smoking, women who were ever exposed had a higher breast cancer risk, with the adjusted odds ratio (OR) and 95% confidence interval (CI) of 1.35 (1.11-1.65). Similar result was found on home passive smoking exposure and breast cancer risk, but not on workplace passive smoking exposure. Women who were ever exposed to tobacco smoke at home had a higher risk of breast cancer compared with never exposed women, with the adjusted OR (95% CI) of 1.30 (1.05-1.61). Home passive smoking exposure showed significant dose-response relationships with breast cancer risk in smoker-years, cigarettes/day and total pack-years (Ptrend=0.003, 0.006 and 0.009, respectively). An increased total smoker-years of any passive exposure significantly elevated the risk of breast cancer (Ptrend<0.001). Positive associations and dose-response relationships were found among postmenopausal women and all subtypes of estrogen receptor (ER) and progesterone receptor (PR) status of breast cancer. Passive smoking was associated with an increased risk of breast cancer among non-smoking Chinese women. A stronger positive association with breast cancer risk was seen mainly among postmenopausal women.

  5. Passive Smoking and Breast Cancer Risk among Non-Smoking Women: A Case-Control Study in China

    PubMed Central

    Li, Bin; Wang, Lian; Lu, Min-Shan; Mo, Xiong-Fei; Lin, Fang-Yu; Ho, Suzanne C.; Zhang, Cai-Xia

    2015-01-01

    Background The role of passive smoking on breast cancer risk was unclear. This study aimed to evaluate the association between passive smoking and breast cancer risk among Chinese women. Methods/Principal Findings A hospital-based case-control study, including 877 breast cancer cases and 890 controls, frequency-matched by age and residence, was conducted. A structured questionnaire was used to collect information on passive smoking history through face-to-face interview by trained interviewers. Unconditional logistic regression models were used to estimate the association between passive smoking and breast cancer risk. A positive association between any passive smoking exposure and breast cancer risk was observed. Compared with women who were never exposed to passive smoking, women who were ever exposed had a higher breast cancer risk, with the adjusted odds ratio (OR) and 95% confidence interval (CI) of 1.35 (1.11-1.65). Similar result was found on home passive smoking exposure and breast cancer risk, but not on workplace passive smoking exposure. Women who were ever exposed to tobacco smoke at home had a higher risk of breast cancer compared with never exposed women, with the adjusted OR (95% CI) of 1.30 (1.05-1.61). Home passive smoking exposure showed significant dose-response relationships with breast cancer risk in smoker-years, cigarettes/day and total pack-years (P trend=0.003, 0.006 and 0.009, respectively). An increased total smoker-years of any passive exposure significantly elevated the risk of breast cancer (P trend<0.001). Positive associations and dose-response relationships were found among postmenopausal women and all subtypes of estrogen receptor (ER) and progesterone receptor (PR) status of breast cancer. Conclusions Passive smoking was associated with an increased risk of breast cancer among non-smoking Chinese women. A stronger positive association with breast cancer risk was seen mainly among postmenopausal women. PMID:25915759

  6. Probing the critical zone using passive- and active-source estimates of subsurface shear-wave velocities

    NASA Astrophysics Data System (ADS)

    Callahan, R. P.; Taylor, N. J.; Pasquet, S.; Dueker, K. G.; Riebe, C. S.; Holbrook, W. S.

    2016-12-01

    Geophysical imaging is rapidly becoming popular for quantifying subsurface critical zone (CZ) architecture. However, a diverse array of measurements and measurement techniques are available, raising the question of which are appropriate for specific study goals. Here we compare two techniques for measuring S-wave velocities (Vs) in the near surface. The first approach quantifies Vs in three dimensions using a passive source and an iterative residual least-squares tomographic inversion. The second approach uses a more traditional active-source seismic survey to quantify Vs in two dimensions via a Monte Carlo surface-wave dispersion inversion. Our analysis focuses on three 0.01 km2 study plots on weathered granitic bedrock in the Southern Sierra Critical Zone Observatory. Preliminary results indicate that depth-averaged velocities from the two methods agree over the scales of resolution of the techniques. While the passive- and active-source techniques both quantify Vs, each method has distinct advantages and disadvantages during data acquisition and analysis. The passive-source method has the advantage of generating a three dimensional distribution of subsurface Vs structure across a broad area. Because this method relies on the ambient seismic field as a source, which varies unpredictably across space and time, data quality and depth of investigation are outside the control of the user. Meanwhile, traditional active-source surveys can be designed around a desired depth of investigation. However, they only generate a two dimensional image of Vs structure. Whereas traditional active-source surveys can be inverted quickly on a personal computer in the field, passive source surveys require significantly more computations, and are best conducted in a high-performance computing environment. We use data from our study sites to compare these methods across different scales and to explore how these methods can be used to better understand subsurface CZ architecture.

  7. Does long-term passive stretching alter muscle-tendon unit mechanics in children with spastic cerebral palsy?

    PubMed

    Theis, Nicola; Korff, Thomas; Mohagheghi, Amir A

    2015-12-01

    Cerebral palsy causes motor impairments during development and many children may experience excessive neural and mechanical muscle stiffness. The clinical assumption is that excessive stiffness is thought to be one of the main reasons for functional impairments in cerebral palsy. As such, passive stretching is widely used to reduce stiffness, with a view to improving function. However, current research evidence on passive stretching in cerebral palsy is not adequate to support or refute the effectiveness of stretching as a management strategy to reduce stiffness and/or improve function. The purpose was to identify the effect of six weeks passive ankle stretching on muscle-tendon unit parameters in children with spastic cerebral palsy. Thirteen children (8-14 y) with quadriplegic/diplegic cerebral palsy were randomly assigned to either an experimental group (n=7) or a control group (n=6). The experimental group underwent an additional six weeks of passive ankle dorsiflexion stretching for 15 min (per leg), four days per week, whilst the control group continued with their normal routine, which was similar for the two groups. Measures of muscle and tendon stiffness, strain and resting length were acquired pre- and post-intervention. The experimental group demonstrated a 3° increase in maximum ankle dorsiflexion. This was accompanied by a 13% reduction in triceps surae muscle stiffness, with no change in tendon stiffness. Additionally, there was an increase in fascicle strain with no changes in resting length, suggesting muscle stiffness reductions were a result of alterations in intra/extra-muscular connective tissue. The results demonstrate that stretching can reduce muscle stiffness by altering fascicle strain but not resting fascicle length. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Controlling adsorption and passivation properties of bovine serum albumin on silica surfaces by ionic strength modulation and cross-linking.

    PubMed

    Park, Jae Hyeon; Sut, Tun Naw; Jackman, Joshua A; Ferhan, Abdul Rahim; Yoon, Bo Kyeong; Cho, Nam-Joon

    2017-03-29

    Understanding the physicochemical factors that influence protein adsorption onto solid supports holds wide relevance for fundamental insights into protein structure and function as well as for applications such as surface passivation. Ionic strength is a key parameter that influences protein adsorption, although how its modulation might be utilized to prepare well-coated protein adlayers remains to be explored. Herein, we investigated how ionic strength can be utilized to control the adsorption and passivation properties of bovine serum albumin (BSA) on silica surfaces. As protein stability in solution can influence adsorption kinetics, the size distribution and secondary structure of proteins in solution were first characterized by dynamic light scattering (DLS), nanoparticle tracking analysis (NTA), and circular dichroism (CD) spectroscopy. A non-monotonic correlation between ionic strength and protein aggregation was observed and attributed to colloidal agglomeration, while the primarily α-helical character of the protein in solution was maintained in all cases. Quartz crystal microbalance-dissipation (QCM-D) experiments were then conducted in order to track protein adsorption onto silica surfaces as a function of ionic strength, and the measurement responses indicated that total protein uptake at saturation coverage is lower with increasing ionic strength. In turn, the QCM-D data and the corresponding Voigt-Voinova model analysis support that the surface area per bound protein molecule is greater with increasing ionic strength. While higher protein uptake under lower ionic strengths by itself did not result in greater surface passivation under subsequent physiologically relevant conditions, the treatment of adsorbed protein layers with a gluteraldehyde cross-linking agent stabilized the bound protein in this case and significantly improved surface passivation. Collectively, our findings demonstrate that ionic strength modulation influences BSA adsorption uptake on account of protein spreading and can be utilized in conjunction with covalent cross-linking strategies to prepare well-coated protein adlayers for improved surface passivation.

  9. Status of the nuclear measurement stations for the process control of spent fuel reprocessing at AREVA NC/La Hague

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eleon, Cyrille; Passard, Christian; Hupont, Nicolas

    2015-07-01

    Nuclear measurements are used at AREVA NC/La Hague for the monitoring of spent fuel reprocessing. The process control is based on gamma-ray spectroscopy, passive neutron counting and active neutron interrogation, and gamma transmission measurements. The main objectives are criticality and safety, online process monitoring, and the determination of the residual fissile mass and activities in the metallic waste remained after fuel shearing and dissolution (empty hulls, grids, end pieces), which are put in radioactive waste drums before compaction. The whole monitoring system is composed of eight measurement stations which will be described in this paper. The main measurement stations no.more » 1, 3 and 7 are needed for criticality control. Before fuel element shearing for dissolution, station no. 1 allows determining the burn-up of the irradiated fuel by gamma-ray spectroscopy with HP Ge (high purity germanium) detectors. The burn-up is correlated to the {sup 137}Cs and {sup 134}Cs gamma emission rates. The fuel maximal mass which can be loaded in one bucket of the dissolver is estimated from the lowest burn-up fraction of the fuel element. Station no. 3 is dedicated to the control of the correct fuel dissolution, which is performed with a {sup 137}Cs gamma ray measurement with a HP Ge detector. Station no. 7 allows estimating the residual fissile mass in the drums filled with the metallic residues, especially in the hulls, from passive neutron counting (spontaneous fission and alpha-n reactions) and active interrogation (fission prompt neutrons induced by a pulsed neutron generator) with proportional {sup 3}He detectors. The measurement stations have been validated for the reprocessing of Uranium Oxide (UOX) fuels with a burn-up rate up to 60 GWd/t. This paper presents a brief overview of the current status of the nuclear measurement stations. (authors)« less

  10. Improving general flexibility with a mind-body approach: a randomized, controlled trial using neuro emotional Technique®.

    PubMed

    Jensen, Anne M; Ramasamy, Adaikalavan; Hall, Michael W

    2012-08-01

    General flexibility is a key component of health, well-being, and general physical conditioning. Reduced flexibility has both physical and mental/emotional etiologies and can lead to musculoskeletal injuries and athletic underperformance. Few studies have tested the effectiveness of a mind-body therapy on general flexibility. The aim of this study was to investigate if Neuro Emotional Technique® (NET), a mind-body technique shown to be effective in reducing stress, can also improve general flexibility. The sit-and-reach test (SR) score was used as a measure of general flexibility. Forty-five healthy participants were recruited from the general population and assessed for their initial SR score before being randomly allocated to receive (a) two 20-minute sessions of NET (experimental group); (b) two 20-minute sessions of stretching instruction (active control group); or (c) no intervention or instruction (passive control group). After intervention, the participants were reassessed in a similar manner by the same blind assessor. The participants also answered questions about demographics, usual water and caffeine consumption, and activity level, and they completed an anxiety/mood psychometric preintervention and postintervention. The mean (SD) change in the SR score was +3.1 cm (2.5) in the NET group, +1.2 cm (2.3) in the active control group and +1.0 cm (2.6) in the passive control group. Although all the 3 groups showed some improvement, the improvement in the NET group was statistically significant when compared with that of either the passive controls (p = 0.015) or the active controls (p = 0.021). This study suggests that NET could provide an effective treatment in improving general flexibility. A larger study is required to confirm these findings and also to assess longer term effectiveness of this therapy on general flexibility.

  11. Semiconductor laser having a non-absorbing passive region with beam guiding

    NASA Technical Reports Server (NTRS)

    Botez, Dan (Inventor)

    1986-01-01

    A laser comprises a semiconductor body having a pair of end faces and including an active region comprising adjacent active and guide layers which is spaced a distance from the end face and a passive region comprising adjacent non-absorbing guide and mode control layers which extends between the active region and the end face. The combination of the guide and mode control layers provides a weak positive index waveguide in the lateral direction thereby providing lateral mode control in the passive region between the active region and the end face.

  12. Impact of Active Control on Passive Safety Response Characteristics of Sodium-cooled Fast Reactors: I - Theoretical background

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Passerini, Stefano; Ponciroli, Roberto; Vilim, Richard B.

    Here, the interaction of the active control system with passive safety behavior is investigated for sodium-cooled fast reactors. A claim often made of advanced reactors is that they are passively safe against unprotected upset events. In practice, such upset events are not analyzed in the context of the plant control system, but rather the analyses are performed without considering the normally programmed response of the control system (open-loop approach). This represents an oversimplification of the safety case. The issue of passive safety override arises since the control system commands actuators whose motions have safety consequences. Depending on the upset involvingmore » the control system ( operator error, active control system failure, or inadvertent control system override), an actuator does not necessarily go in the same direction as needed for safety. So neglecting to account for control system action during an unprotected upset is nonconservative from a safety standpoint. It is important then, during the design of the plant, to consider the potential for the control system to work against the inherent and safe regulating effects of purposefully engineered temperature feedbacks.« less

  13. Impact of Active Control on Passive Safety Response Characteristics of Sodium-cooled Fast Reactors: I - Theoretical background

    DOE PAGES

    Passerini, Stefano; Ponciroli, Roberto; Vilim, Richard B.

    2017-06-21

    Here, the interaction of the active control system with passive safety behavior is investigated for sodium-cooled fast reactors. A claim often made of advanced reactors is that they are passively safe against unprotected upset events. In practice, such upset events are not analyzed in the context of the plant control system, but rather the analyses are performed without considering the normally programmed response of the control system (open-loop approach). This represents an oversimplification of the safety case. The issue of passive safety override arises since the control system commands actuators whose motions have safety consequences. Depending on the upset involvingmore » the control system ( operator error, active control system failure, or inadvertent control system override), an actuator does not necessarily go in the same direction as needed for safety. So neglecting to account for control system action during an unprotected upset is nonconservative from a safety standpoint. It is important then, during the design of the plant, to consider the potential for the control system to work against the inherent and safe regulating effects of purposefully engineered temperature feedbacks.« less

  14. Comparison of epicardial deformation in passive and active isolated rabbit hearts

    NASA Astrophysics Data System (ADS)

    Ho, Andrew; Tang, Liang; Chiang, Fu-Pen; Lin, Shien-Fong

    2007-02-01

    Mechanical deformation of isolated rabbit hearts through passive inflation techniques have been a viable form of replicating heart motion, but its relation to the heart's natural active contractions remain unclear. The mechanical properties of the myocardium may show diverse characteristics while in tension and compression. In this study, epicardial strain was measured with the assistance of computer-aided speckle interferometry (CASI)1. CASI tracks the movement of clusters of particles for measuring epicardial deformation. The heart was cannulated and perfused with Tyrode's solution. Silicon carbide particles were applied onto the myocardium to form random speckle pattern images while the heart was allowed to actively contract and stabilize. High resolution videos (1000x1000 pixels) of the left ventricle were taken with a complementary metal oxide semiconductor (CMOS) camera as the heart was actively contracting through electrical pacing at various cycle lengths between 250-800 ms. A latex balloon was then inserted into the left ventricle via left atrium and videos were taken as the balloon was repeatedly inflated and deflated at controlled volumes (1-3 ml/cycle). The videos were broken down into frames and analyzed through CASI. Active contractions resulted in non-uniform circular epicardial and uniaxial contractions at different stages of the motion. In contrast, the passive heart demonstrated very uniform expansion and contraction originating from the source of the latex balloon. The motion of the active heart caused variations in deformation, but in comparison to the passive heart, had a more enigmatic displacement field. The active heart demonstrated areas of large displacement and others with relatively no displacement. Application of CASI was able to successfully distinguish the motions between the active and passive hearts.

  15. Design of an Embedded CMOS Temperature Sensor for Passive RFID Tag Chips.

    PubMed

    Deng, Fangming; He, Yigang; Li, Bing; Zhang, Lihua; Wu, Xiang; Fu, Zhihui; Zuo, Lei

    2015-05-18

    This paper presents an ultra-low embedded power temperature sensor for passive RFID tags. The temperature sensor converts the temperature variation to a PTAT current, which is then transformed into a temperature-controlled frequency. A phase locked loop (PLL)-based sensor interface is employed to directly convert this temperature-controlled frequency into a corresponding digital output without an external reference clock. The fabricated sensor occupies an area of 0.021 mm2 using the TSMC 0.18 1P6M mixed-signal CMOS process. Measurement results of the embedded sensor within the tag system shows a 92 nW power dissipation under 1.0 V supply voltage at room temperature, with a sensing resolution of 0.15 °C/LSB and a sensing accuracy of -0.7/0.6 °C from -30 °C to 70 °C after 1-point calibration at 30 °C.

  16. Design of an Embedded CMOS Temperature Sensor for Passive RFID Tag Chips

    PubMed Central

    Deng, Fangming; He, Yigang; Li, Bing; Zhang, Lihua; Wu, Xiang; Fu, Zhihui; Zuo, Lei

    2015-01-01

    This paper presents an ultra-low embedded power temperature sensor for passive RFID tags. The temperature sensor converts the temperature variation to a PTAT current, which is then transformed into a temperature-controlled frequency. A phase locked loop (PLL)-based sensor interface is employed to directly convert this temperature-controlled frequency into a corresponding digital output without an external reference clock. The fabricated sensor occupies an area of 0.021 mm2 using the TSMC 0.18 1P6M mixed-signal CMOS process. Measurement results of the embedded sensor within the tag system shows a 92 nW power dissipation under 1.0 V supply voltage at room temperature, with a sensing resolution of 0.15 °C/LSB and a sensing accuracy of −0.7/0.6 °C from −30 °C to 70 °C after 1-point calibration at 30 °C. PMID:25993518

  17. Effects that passive cycling exercise have on muscle strength, duration of mechanical ventilation, and length of hospital stay in critically ill patients: a randomized clinical trial

    PubMed Central

    Machado, Aline dos Santos; Pires-Neto, Ruy Camargo; Carvalho, Maurício Tatsch Ximenes; Soares, Janice Cristina; Cardoso, Dannuey Machado; de Albuquerque, Isabella Martins

    2017-01-01

    ABSTRACT Objective: To evaluate the effects that passive cycling exercise, in combination with conventional physical therapy, have on peripheral muscle strength, duration of mechanical ventilation, and length of hospital stay in critically ill patients admitted to the ICU of a tertiary care university hospital. Methods: This was a randomized clinical trial involving 38 patients (≥ 18 years of age) on mechanical ventilation who were randomly divided into two groups: control (n = 16), receiving conventional physical therapy; and intervention (n = 22), receiving conventional physical therapy and engaging in passive cycling exercise five days per week. The mean age of the patients was 46.42 ± 16.25 years, and 23 were male. The outcomes studied were peripheral muscle strength, as measured by the Medical Research Council scale, duration of mechanical ventilation, and length of hospital stay. Results: There was a significant increase in peripheral muscle strength (baseline vs. final) in both groups (control: 40.81 ± 7.68 vs. 45.00 ± 6.89; and intervention: 38.73 ± 11.11 vs. 47.18 ± 8.75; p < 0.001 for both). However, the range of increase in strength was higher in the intervention group than in the control group (8.45 ± 5.20 vs. 4.18 ± 2.63; p = 0.005). There were no significant differences between the groups in terms of duration of mechanical ventilation or length of hospital stay. Conclusions: The results suggest that the performance of continuous passive mobilization on a cyclical basis helps to recover peripheral muscle strength in ICU patients. (ClinicalTrials.gov Identifier: NCT01769846 [http://www.clinicaltrials.gov/]) PMID:28538781

  18. Chronic cyanidin-3-glucoside administration improves short-term spatial recognition memory but not passive avoidance learning and memory in streptozotocin-diabetic rats.

    PubMed

    Nasri, Sima; Roghani, Mehrdad; Baluchnejadmojarad, Tourandokht; Balvardi, Mahboubeh; Rabani, Tahereh

    2012-08-01

    This research study was conducted to evaluate the efficacy of chronic cyanidin-3-glucoside (C3G) on alleviation of learning and memory deficits in diabetic rats as a result of the observed antidiabetic and antioxidant activity of C3G. Male Wistar rats were divided into control, diabetic, C3G-treated-control and -diabetic groups. The C3G was administered i.p. at a dose of 10 mg/kg on alternate days for eight weeks. For evaluation of learning and memory, initial latency (IL) and step-through latency (STL) were determined at the end of study using passive avoidance test. Meanwhile, spatial recognition memory was assessed as alternation in the Y-maze task. Oxidative stress markers in brain tissue were also measured. It was found that the alternation score of the diabetic rats was lower than that of control (p < 0.01) and C3G-treated diabetic rats showed a higher alternation score as compared to diabetic group (p < 0.05). Diabetic rats also developed a significant impairment in retention and recall in passive avoidance test (p < 0.01) and C3G treatment of diabetic rats did not produce any significant improvement. Meanwhile, increased level of malondialdehyde (MDA) in diabetic rats was significantly reduced following C3G treatment (p < 0.05). Taken together, chronic C3G could improve short-term spatial recognition memory disturbance in the Y-maze test but not retention and recall capability in passive avoidance test in STZ-diabetic rats. Copyright © 2012 John Wiley & Sons, Ltd.

  19. A Null Space Control of Two Wheels Driven Mobile Manipulator Using Passivity Theory

    NASA Astrophysics Data System (ADS)

    Shibata, Tsuyoshi; Murakami, Toshiyuki

    This paper describes a control strategy of null space motion of a two wheels driven mobile manipulator. Recently, robot is utilized in various industrial fields and it is preferable for the robot manipulator to have multiple degrees of freedom motion. Several studies of kinematics for null space motion have been proposed. However stability analysis of null space motion is not enough. Furthermore, these approaches apply to stable systems, but they do not apply unstable systems. Then, in this research, base of manipulator equips with two wheels driven mobile robot. This robot is called two wheels driven mobile manipulator, which becomes unstable system. In the proposed approach, a control design of null space uses passivity based stabilizing. A proposed controller is decided so that closed-loop system of robot dynamics satisfies passivity. This is passivity based control. Then, control strategy is that stabilizing of the robot system applies to work space observer based approach and null space control while keeping end-effector position. The validity of the proposed approach is verified by simulations and experiments of two wheels driven mobile manipulator.

  20. Processing implicit control: evidence from reading times

    PubMed Central

    McCourt, Michael; Green, Jeffrey J.; Lau, Ellen; Williams, Alexander

    2015-01-01

    Sentences such as “The ship was sunk to collect the insurance” exhibit an unusual form of anaphora, implicit control, where neither anaphor nor antecedent is audible. The non-finite reason clause has an understood subject, PRO, that is anaphoric; here it may be understood as naming the agent of the event of the host clause. Yet since the host is a short passive, this agent is realized by no audible dependent. The putative antecedent to PRO is therefore implicit, which it normally cannot be. What sorts of representations subserve the comprehension of this dependency? Here we present four self-paced reading time studies directed at this question. Previous work showed no processing cost for implicit vs. explicit control, and took this to support the view that PRO is linked syntactically to a silent argument in the passive. We challenge this conclusion by reporting that we also find no processing cost for remote implicit control, as in: “The ship was sunk. The reason was to collect the insurance.” Here the dependency crosses two independent sentences, and so cannot, we argue, be mediated by syntax. Our Experiments 1–4 examined the processing of both implicit (short passive) and explicit (active or long passive) control in both local and remote configurations. Experiments 3 and 4 added either “3 days ago” or “just in order” to the local conditions, to control for the distance between the passive and infinitival verbs, and for the predictability of the reason clause, respectively. We replicate the finding that implicit control does not impose an additional processing cost. But critically we show that remote control does not impose a processing cost either. Reading times at the reason clause were never slower when control was remote. In fact they were always faster. Thus, efficient processing of local implicit control cannot show that implicit control is mediated by syntax; nor, in turn, that there is a silent but grammatically active argument in passives. PMID:26579016

  1. Confocal imaging to quantify passive transport across biomimetic lipid membranes.

    PubMed

    Li, Su; Hu, Peichi; Malmstadt, Noah

    2010-09-15

    The ability of a molecule to pass through the plasma membrane without the aid of any active cellular mechanisms is central to that molecule's pharmaceutical characteristics. Passive transport has been understood in the context of Overton's rule, which states that more lipophilic molecules cross membrane lipid bilayers more readily. Existing techniques for measuring passive transport lack reproducibility and are hampered by the presence of an unstirred layer (USL) that dominates transport across the bilayer. This report describes assays based on spinning-disk confocal microscopy (SDCM) of giant unilamellar vesicles (GUVs) that allow for the detailed investigation of passive transport processes and mechanisms. This approach allows the concentration field to be directly observed, allowing membrane permeability to be determined easily from the transient concentration profile data. A series of molecules of increasing hydrophilicity was constructed, and the transport of these molecules into GUVs was observed. The observed permeability trend is consistent with Overton's rule. However, the values measured depart from the simple partition-diffusion proportionality model of passive transport. This technique is easy to implement and has great promise as an approach to measure membrane transport. It is optimally suited to precise quantitative measurements of the dependence of passive transport on membrane properties.

  2. Passive exposure to electronic cigarette (e-cigarette) use increases desire for combustible and e-cigarettes in young adult smokers.

    PubMed

    King, Andrea C; Smith, Lia J; McNamara, Patrick J; Matthews, Alicia K; Fridberg, Daniel J

    2015-09-01

    Passive exposure to combustible cigarette use has been shown to act as a cue to increase smoking urge. Given the resemblance of e-cigarettes and other electronic nicotine delivery systems (ENDS) to combustible cigarettes, we examined whether these devices could also act as a cue to increase smoking desire and urges in those passively exposed. Young adult daily smokers (age 18-35 years; N=60) completed subjective ratings before and after exposure to a study confederate drinking bottled water (control cue) and then smoking either a combustible or e-cigarette (active cue). Smoking desire and urge ratings were measured with visual analogue scale items for desire for a regular and an e-cigarette and the Brief Questionnaire of Smoking Urges. Passive exposure to both the e-cigarette and combustible cigarette cue significantly increased observers' ratings of desire and urge to smoke a regular cigarette (all ps<0.05). Exposure to the e-cigarette cue but not the regular cigarette cue also increased desire to smoke an e-cigarette (p<0.01). The results provide the first evidence in a controlled setting that electronic cigarette exposure may evoke smoking urges in young adult daily smokers. With replication, these findings may have relevance for ENDS regulation and policy. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  3. Ankle manual therapy for individuals with post-acute ankle sprains: description of a randomized, placebo-controlled clinical trial

    PubMed Central

    2010-01-01

    Background Ankle sprains are common within the general population and can result in prolonged disablement. Limited talocrural dorsiflexion range of motion (DF ROM) is a common consequence of ankle sprain. Limited talocrural DF ROM may contribute to persistent symptoms, disability, and an elevated risk for re-injury. As a result, many health care practitioners use hands-on passive procedures with the intention of improving talocrural joint DF ROM in individuals following ankle sprains. Dosage of passive hands-on procedures involves a continuum of treatment speeds. Recent evidence suggests both slow- and fast-speed treatments may be effective to address disablement following ankle sprains. However, these interventions have yet to be longitudinally compared against a placebo study condition. Methods/Design We developed a randomized, placebo-controlled clinical trial designed to test the hypotheses that hands-on treatment procedures administered to individuals following ankle sprains during the post-acute injury period can improve short-, intermediate-, and long-term disablement, as well as reduce the risk for re-injury. Discussion This study is designed to measure the clinical effects of hands-on passive stretching treatment procedures directed to the talocrural joint that vary in treatment speed during the post-acute injury period, compared to hands-on placebo control intervention. Trial Registration http://www.clinicaltrials.gov identifier NCT00888498. PMID:20958995

  4. An Ultra-Low-Power RFID/NFC Frontend IC Using 0.18 μm CMOS Technology for Passive Tag Applications.

    PubMed

    Bhattacharyya, Mayukh; Gruenwald, Waldemar; Jansen, Dirk; Reindl, Leonhard; Aghassi-Hagmann, Jasmin

    2018-05-07

    Battery-less passive sensor tags based on RFID or NFC technology have achieved much popularity in recent times. Passive tags are widely used for various applications like inventory control or in biotelemetry. In this paper, we present a new RFID/NFC frontend IC (integrated circuit) for 13.56 MHz passive tag applications. The design of the frontend IC is compatible with the standard ISO 15693/NFC 5. The paper discusses the analog design part in details with a brief overview of the digital interface and some of the critical measured parameters. A novel approach is adopted for the demodulator design, to demodulate the 10% ASK (amplitude shift keying) signal. The demodulator circuit consists of a comparator designed with a preset offset voltage. The comparator circuit design is discussed in detail. The power consumption of the bandgap reference circuit is used as the load for the envelope detection of the ASK modulated signal. The sub-threshold operation and low-supply-voltage are used extensively in the analog design—to keep the power consumption low. The IC was fabricated using 0.18 μ m CMOS technology in a die area of 1.5 mm × 1.5 mm and an effective area of 0.7 m m 2 . The minimum supply voltage desired is 1.2 V, for which the total power consumption is 107 μ W. The analog part of the design consumes only 36 μ W, which is low in comparison to other contemporary passive tags ICs. Eventually, a passive tag is developed using the frontend IC, a microcontroller, a temperature and a pressure sensor. A smart NFC device is used to readout the sensor data from the tag employing an Android-based application software. The measurement results demonstrate the full passive operational capability. The IC is suitable for low-power and low-cost industrial or biomedical battery-less sensor applications. A figure-of-merit (FOM) is proposed in this paper which is taken as a reference for comparison with other related state-of-the-art researches.

  5. An Ultra-Low-Power RFID/NFC Frontend IC Using 0.18 μm CMOS Technology for Passive Tag Applications

    PubMed Central

    Gruenwald, Waldemar; Jansen, Dirk; Aghassi-Hagmann, Jasmin

    2018-01-01

    Battery-less passive sensor tags based on RFID or NFC technology have achieved much popularity in recent times. Passive tags are widely used for various applications like inventory control or in biotelemetry. In this paper, we present a new RFID/NFC frontend IC (integrated circuit) for 13.56 MHz passive tag applications. The design of the frontend IC is compatible with the standard ISO 15693/NFC 5. The paper discusses the analog design part in details with a brief overview of the digital interface and some of the critical measured parameters. A novel approach is adopted for the demodulator design, to demodulate the 10% ASK (amplitude shift keying) signal. The demodulator circuit consists of a comparator designed with a preset offset voltage. The comparator circuit design is discussed in detail. The power consumption of the bandgap reference circuit is used as the load for the envelope detection of the ASK modulated signal. The sub-threshold operation and low-supply-voltage are used extensively in the analog design—to keep the power consumption low. The IC was fabricated using 0.18 μm CMOS technology in a die area of 1.5 mm × 1.5 mm and an effective area of 0.7 mm2. The minimum supply voltage desired is 1.2 V, for which the total power consumption is 107 μW. The analog part of the design consumes only 36 μW, which is low in comparison to other contemporary passive tags ICs. Eventually, a passive tag is developed using the frontend IC, a microcontroller, a temperature and a pressure sensor. A smart NFC device is used to readout the sensor data from the tag employing an Android-based application software. The measurement results demonstrate the full passive operational capability. The IC is suitable for low-power and low-cost industrial or biomedical battery-less sensor applications. A figure-of-merit (FOM) is proposed in this paper which is taken as a reference for comparison with other related state-of-the-art researches. PMID:29735939

  6. Application of a passivity based control methodology for flexible joint robots to a simplified Space Shuttle RMS

    NASA Technical Reports Server (NTRS)

    Sicard, Pierre; Wen, John T.

    1992-01-01

    A passivity approach for the control design of flexible joint robots is applied to the rate control of a three-link arm modeled after the shoulder yaw joint of the Space Shuttle Remote Manipulator System (RMS). The system model includes friction and elastic joint couplings modeled as nonlinear springs. The basic structure of the proposed controller is the sum of a model-based feedforward and a model-independent feedback. A regulator approach with link state feedback is employed to define the desired motor state. Passivity theory is used to design a motor state-based controller to stabilize the error system formed by the feedforward. Simulation results show that greatly improved performance was obtained by using the proposed controller over the existing RMS controller.

  7. Finite-time robust passive control for a class of switched reaction-diffusion stochastic complex dynamical networks with coupling delays and impulsive control

    NASA Astrophysics Data System (ADS)

    Syed Ali, M.; Yogambigai, J.; Kwon, O. M.

    2018-03-01

    Finite-time boundedness and finite-time passivity for a class of switched stochastic complex dynamical networks (CDNs) with coupling delays, parameter uncertainties, reaction-diffusion term and impulsive control are studied. Novel finite-time synchronisation criteria are derived based on passivity theory. This paper proposes a CDN consisting of N linearly and diffusively coupled identical reaction- diffusion neural networks. By constructing of a suitable Lyapunov-Krasovskii's functional and utilisation of Jensen's inequality and Wirtinger's inequality, new finite-time passivity criteria for the networks are established in terms of linear matrix inequalities (LMIs), which can be checked numerically using the effective LMI toolbox in MATLAB. Finally, two interesting numerical examples are given to show the effectiveness of the theoretical results.

  8. Field-testing a new directional passive air sampler for fugitive dust in a complex industrial source environment.

    PubMed

    Ferranti, E J S; Fryer, M; Sweetman, A J; Garcia, M A Solera; Timmis, R J

    2014-01-01

    Quantifying the sources of fugitive dusts on complex industrial sites is essential for regulation and effective dust management. This study applied two recently-patented Directional Passive Air Samplers (DPAS) to measure the fugitive dust contribution from a Metal Recovery Plant (MRP) located on the periphery of a major steelworks site. The DPAS can collect separate samples for winds from different directions (12 × 30° sectors), and the collected dust may be quantified using several different measurement methods. The DPASs were located up and down-prevailing-wind of the MRP processing area to (i) identify and measure the contribution made by the MRP processing operation; (ii) monitor this contribution during the processing of a particularly dusty material; and (iii) detect any changes to this contribution following new dust-control measures. Sampling took place over a 12-month period and the amount of dust was quantified using photographic, magnetic and mass-loading measurement methods. The DPASs are able to effectively resolve the incoming dust signal from the wider steelworks complex, and also different sources of fugitive dust from the MRP processing area. There was no confirmable increase in the dust contribution from the MRP during the processing of a particularly dusty material, but dust levels significantly reduced following the introduction of new dust-control measures. This research was undertaken in a regulatory context, and the results provide a unique evidence-base for current and future operational or regulatory decisions.

  9. Realization of Intelligent Measurement and Control System for Limb Rehabilitation Based on PLC and Touch Screen

    NASA Astrophysics Data System (ADS)

    Liu, Xiangquan

    According to the treatment needs of patients with limb movement disorder, on the basis of the limb rehabilitative training prototype, function of measure and control system are analyzed, design of system hardware and software is completed. The touch screen which is adopt as host computer and man-machine interaction window is responsible for sending commands and training information display; The PLC which is adopt as slave computer is responsible for receiving control command from touch screen, collecting the sensor data, regulating torque and speed of motor by analog output according to the different training mode, realizing ultimately active and passive training for limb rehabilitation therapy.

  10. Sound source measurement by using a passive sound insulation and a statistical approach

    NASA Astrophysics Data System (ADS)

    Dragonetti, Raffaele; Di Filippo, Sabato; Mercogliano, Francesco; Romano, Rosario A.

    2015-10-01

    This paper describes a measurement technique developed by the authors that allows carrying out acoustic measurements inside noisy environments reducing background noise effects. The proposed method is based on the integration of a traditional passive noise insulation system with a statistical approach. The latter is applied to signals picked up by usual sensors (microphones and accelerometers) equipping the passive sound insulation system. The statistical approach allows improving of the sound insulation given only by the passive sound insulation system at low frequency. The developed measurement technique has been validated by means of numerical simulations and measurements carried out inside a real noisy environment. For the case-studies here reported, an average improvement of about 10 dB has been obtained in a frequency range up to about 250 Hz. Considerations on the lower sound pressure level that can be measured by applying the proposed method and the measurement error related to its application are reported as well.

  11. Wireless passive radiation sensor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pfeifer, Kent B; Rumpf, Arthur N; Yelton, William G

    2013-12-03

    A novel measurement technique is employed using surface acoustic wave (SAW) devices, passive RF, and radiation-sensitive films to provide a wireless passive radiation sensor that requires no batteries, outside wiring, or regular maintenance. The sensor is small (<1 cm.sup.2), physically robust, and will operate unattended for decades. In addition, the sensor can be insensitive to measurement position and read distance due to a novel self-referencing technique eliminating the need to measure absolute responses that are dependent on RF transmitter location and power.

  12. Comparing Active and Passive Distraction-Based Music Therapy Interventions on Preoperative Anxiety in Pediatric Patients and Their Caregivers.

    PubMed

    Millett, Christopher R; Gooding, Lori F

    2018-01-13

    Young children who experience high levels of preoperative anxiety often exhibit distress behaviors, experience more surgical complications, and are at a higher risk for developing a variety of negative postoperative consequences. A significant factor in pediatric preoperative anxiety is the level of anxiety present in their caregivers. Active and passive music therapy interventions addressing anxiety prior to invasive procedures have been met with success. The purpose of this study was to investigate the comparative effectiveness of two distraction-based music therapy interventions on reducing preoperative anxiety in young pediatric surgical patients and their caregivers. A total of 40 pediatric patient and caregiver dyads undergoing ambulatory surgery were included in this study. Pediatric preoperative anxiety was measured pre- and post-intervention using the modified Yale Pediatric Anxiety Scale, while caregiver anxiety was measured through self-report using the short-form Strait-Trait Anxiety Inventory-Y6. Participants were randomized to either an active or passive intervention group for a preoperative music therapy session. Results indicated a significant reduction in preoperative anxiety for both patients and their caregivers regardless of intervention type. Neither active nor passive music therapy interventions were significantly more effective than the other. For future studies, the researchers recommend an increased sample size, controlling for various factors such as sedative premedication use, and testing interventions with patients in various stages of development. © the American Music Therapy Association 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  13. The effect of subthalamic stimulation on viscoelastic stiffness of skeletal muscles in patients with Parkinson's disease.

    PubMed

    Rätsep, Tõnu; Asser, Toomas

    2017-05-01

    Myotonometric evaluation of viscoelastic stiffness of skeletal muscles has been proposed to document the effect of surgical or pharmacological treatment on rigidity in patients with Parkinson's disease. The aim of the study was to analyze the changes of viscoelastic stiffness induced by deep brain stimulation. Fifteen patients in an advanced stage of Parkinson's disease participated in the study. The study took place in the off-medication conditions after one night of drug withdrawal. The Unified Parkinson's Disease Rating Scale was used for clinical assessment of the disease. Myotonometry was used to measure viscoelastic stiffness in the resting muscles before and directly after passive wrist movements, commonly used for clinical evaluation of rigidity. The measurements were repeated during the stimulation-on and stimulation-off periods and compared with fifteen healthy control persons. The clinical scores for wrist rigidity improved from 3.0 (1-4) to 0.93 (0-2) (P<0.05) due to brain stimulation. The mean values of viscoelastic stiffness were similar before and after passive wrist movements, but the differences between the patients with high vs. low rigidity values (354.9 vs 310.2N/m; P<0.05) and in stimulation-off vs. stimulation-on conditions (342.7 vs 310.5N/m; P<0.05) were significant only if the measurements had been performed after passive wrist movements. Effective deep brain stimulation and increased rigidity can significantly change viscoelastic stiffness in the resting muscles in patients with Parkinson's disease, especially if evaluated after passive wrist movements. This paper supports the use of myotonometry for objective quantification of parkinsonian rigidity at rest. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. The intra-day dynamics of affect, self-esteem, tiredness, and suicidality in Major Depression.

    PubMed

    Crowe, Eimear; Daly, Michael; Delaney, Liam; Carroll, Susan; Malone, Kevin M

    2018-02-21

    Despite growing interest in the temporal dynamics of Major Depressive Disorder (MDD), we know little about the intra-day fluctuations of key symptom constructs. In a study of momentary experience, the Experience Sampling Method captured the within-day dynamics of negative affect, positive affect, self-esteem, passive suicidality, and tiredness across clinical MDD (N= 31) and healthy control groups (N= 33). Ten symptom measures were taken per day over 6 days (N= 2231 observations). Daily dynamics were modeled via intra-day time-trends, variability, and instability in symptoms. MDD participants showed significantly increased variability and instability in negative affect, positive affect, self-esteem, and suicidality. Significantly different time-trends were found in positive affect (increased diurnal variation and an inverted U-shaped pattern in MDD, compared to a positive linear trend in controls) and tiredness (decreased diurnal variation in MDD). In the MDD group only, passive suicidality displayed a negative linear trend and self-esteem displayed a quadratic inverted U trend. MDD and control participants thus showed distinct dynamic profiles in all symptoms measured. As well as the overall severity of symptoms, intra-day dynamics appear to define the experience of MDD symptoms. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Effects of a capacitive-resistive electric transfer therapy on physiological and biomechanical parameters in recreational runners: A randomized controlled crossover trial.

    PubMed

    Duñabeitia, Iratxe; Arrieta, Haritz; Torres-Unda, Jon; Gil, Javier; Santos-Concejero, Jordan; Gil, Susana M; Irazusta, Jon; Bidaurrazaga-Letona, Iraia

    2018-05-26

    This study compared the effects of a capacitive-resistive electric transfer therapy (Tecar) and passive rest on physiological and biomechanical parameters in recreational runners when performed shortly after an exhausting training session. Randomized controlled crossover trial. University biomechanical research laboratory. Fourteen trained male runners MAIN OUTCOME MEASURES: Physiological (running economy, oxygen uptake, respiratory exchange ratio, ventilation, heart rate, blood lactate concentration) and biomechanical (step length; stride angle, height, frequency, and contact time; swing time; contact phase; support phase; push-off phase) parameters were measured during two incremental treadmill running tests performed two days apart after an exhaustive training session. When running at 14 km/h and 16 km/h, the Tecar treatment group presented greater increases in stride length (p < 0.001), angle (p < 0.05) and height (p < 0.001) between the first and second tests than the control group and, accordingly, greater decreases in stride frequency (p < 0.05). Physiological parameters were similar between groups. The present study suggests that a Tecar therapy intervention enhances biomechanical parameters in recreational runners after an exhaustive training session more than passive rest, generating a more efficient running pattern without affecting selected physiological parameters. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. Evaluating the Relationship between Equilibrium Passive ...

    EPA Pesticide Factsheets

    This Critcal Review evaluates passive sampler uptake of hydrophobic organic contaminants (HOCs) in water column and interstitial water exposures as a surrogate for organism bioaccumulation. Fifty-seven studies were found where both passive sampler uptake and organism bioaccumulation were measured and 19 of these investigations provided direct comparisons relating passive sampler uptake and organism bioaccumulation. Polymers compared included low-density polyethylene (LDPE), polyoxymethylene (POM), and polydimethylsiloxane (PDMS), and organisms ranged from polychaetes and oligochaetes to bivalves, aquatic insects, and gastropods. Regression equations correlating bioaccumulation (CL) and passive sampler uptake (CPS) were used to assess the strength of observed relationships. Passive sampling based concentrations resulted in log–log predictive relationships, most of which were within one to 2 orders of magnitude of measured bioaccumulation. Mean coefficients of determination (r2) for LDPE, PDMS, and POM were 0.68, 0.76, and 0.58, respectively. For the available raw, untransformed data, the mean ratio of CL and CPS was 10.8 ± 18.4 (n = 609). Using passive sampling as a surrogate for organism bioaccumulation is viable when biomonitoring organisms are not available. Passive sampling based estimates of bioaccumulation provide useful information for making informed decisions about the bioavailability of HOCs. This review evaluates passive sampler uptake of hydrophobi

  17. Development of a passive doas system to retrieve atmospheric pollution columns in the 200 to 355 nm region.

    PubMed

    Mejía, Rubén Galicia; Vázquez, Josémanueldelarosa; Isakina, Suren Stolik; García, Edgard Moreno; Iglesias, Gustavo Sosa

    2013-01-08

    In recent years several techniques have been developed to measure and monitor the pollution of the air. Among these techniques, remote sensing using optical methods stands out due to several advantages for air quality control applications. A Passive Differential Optical Absorption Spectroscopy system that uses the ultraviolet region from 200 to 355 nm of the solar radiation is presented. The developed system is portable; therefore it is practical for real time and in situ measurements. The enhanced wavelength range of the system is intended to detect the ultraviolet light penetration in the Mexican Valley considering the solar zenith angle and the altitude. The system was applied to retrieve atmospheric SO2 columns emitted either by anthropogenic (power plant) or natural sources (volcano), reaching a detection limit of about 1 ppm. The measurement of the penetrating solar radiation on the earth surface at the UVC range is presented and the possibility to measure pollution traces of some contaminants as O3, NO2 and aromatic compounds in real time and in situ in the ultraviolet region is discussed.

  18. Development of a passive doas system to retrieve atmospheric pollution columns in the 200 to 355 nm region

    PubMed Central

    2013-01-01

    In recent years several techniques have been developed to measure and monitor the pollution of the air. Among these techniques, remote sensing using optical methods stands out due to several advantages for air quality control applications. A Passive Differential Optical Absorption Spectroscopy system that uses the ultraviolet region from 200 to 355 nm of the solar radiation is presented. The developed system is portable; therefore it is practical for real time and in situ measurements. The enhanced wavelength range of the system is intended to detect the ultraviolet light penetration in the Mexican Valley considering the solar zenith angle and the altitude. The system was applied to retrieve atmospheric SO2 columns emitted either by anthropogenic (power plant) or natural sources (volcano), reaching a detection limit of about 1 ppm. The measurement of the penetrating solar radiation on the earth surface at the UVC range is presented and the possibility to measure pollution traces of some contaminants as O3, NO2 and aromatic compounds in real time and in situ in the ultraviolet region is discussed. PMID:23369629

  19. Silicon surface passivation by silicon nitride deposition

    NASA Technical Reports Server (NTRS)

    Olsen, L. C.

    1984-01-01

    Silicon nitride deposition was studied as a method of passivation for silicon solar cell surfaces. The following three objectives were the thrust of the research: (1) the use of pecvd silicon nitride for passivation of silicon surfaces; (2) measurement techniques for surface recombination velocity; and (3) the importance of surface passivation to high efficiency solar cells.

  20. The Onset Time of the Ownership Sensation in the Moving Rubber Hand Illusion.

    PubMed

    Kalckert, Andreas; Ehrsson, H H

    2017-01-01

    The rubber hand illusion (RHI) is a perceptual illusion whereby a model hand is perceived as part of one's own body. This illusion has been extensively studied, but little is known about the temporal evolution of this perceptual phenomenon, i.e., how long it takes until participants start to experience ownership over the model hand. In the present study, we investigated a version of the rubber hand experiment based on finger movements and measured the average onset time in active and passive movement conditions. This comparison enabled us to further explore the possible role of intentions and motor control processes that are only present in the active movement condition. The results from a large group of healthy participants ( n = 117) showed that the illusion of ownership took approximately 23 s to emerge (active: 22.8; passive: 23.2). The 90th percentile occurs in both conditions within approximately 50 s (active: 50; passive: 50.6); therefore, most participants experience the illusion within the first minute. We found indirect evidence of a facilitatory effect of active movements compared to passive movements, and we discuss these results in the context of our current understanding of the processes underlying the moving RHI.

  1. Translational damping on high-frequency flapping wings

    NASA Astrophysics Data System (ADS)

    Parks, Perry A.

    Flapping fliers such as insects and birds depend on passive translational and rotational damping to terminate quick maneuvers and to provide a source of partial stability in an otherwise unstable dynamic system. Additionally, passive translational and rotational damping reduce the amount of active kinematic changes that must be made to terminate maneuvers and maintain stability. The study of flapping-induced damping phenomena also improves the understanding of micro air vehicle (MAV) dynamics needed for the synthesis of effective flight control strategies. Aerodynamic processes which create passive translational and rotational damping as a direct result of symmetric flapping with no active changes in wing kinematics have been previously studied and were termed flapping counter-force (FCF) and flapping counter-torque (FCT), respectively. In this first study of FCF measurement in air, FCF generation is measured using a pendulum system designed to isolate and measure the relationship of translational flapping-induced damping with wingbeat frequency for a 2.86 gram mechanical flapper equipped with real cicada wings. Analysis reveals that FCF generation and wingbeat frequency are directly proportional, as expected from previous work. The quasi-steady FCF model using Blade-Element-Theory is used as an estimate for translational flapping-induced damping. In most cases, the model proves to be accurate in predicting the relationship between flapping-induced damping and wingbeat frequency. "Forward-backward" motion proves to have the strongest flapping-induced damping while "up-down" motion has the weakest.

  2. Sciatic nerve stiffness is not changed immediately after a slump neurodynamics technique

    PubMed Central

    Neto, Tiago; Freitas, Sandro R; Andrade, Ricardo J; Gomes, João; Vaz, João; Mendes, Bruno; Firmino, Telmo; Nordez, Antoine; Oliveira, Raúl

    2017-01-01

    Summary Background Neurodynamics techniques aim to assess and improve neural mechanosensitivity. However, there is no in vivo evidence regarding the mechanical effects of these techniques in the nerve stiffness. This study examined the immediate effects of a slump neurodynamics technique in the sciatic nerve shear wave velocity (SWV. i.e. an index of stiffness) using ultrasound-based elastography. Methods Fourteen healthy participants were included in this experiment. Sciatic SWV and ankle passive torque were measured during a passive ankle dorsiflexion motion (2°/s), before and immediately after 3 minutes of slump neurodynamics technique, randomly applied to one lower limb. The contralateral limb served as control. Results The slump intervention did not change the sciatic SWV (P=0.78), nor the dorsiflexion passive torque (P=0.14), throughout the ankle dorsiflexion motion. Excellent values of intra-rater repeatability (ICC=0.88, 0.68–0.96), and low values of standard error of measurement (0.59 m/s, 0.35–1.15m/s), were observed for the SWV measurements. Conclusions The sciatic nerve stiffness of healthy participants did not change immediately after a slump neurodynamics technique, suggesting a compliance of the neural tissue to tensile loads. However, these results ought to be confirmed using other neurodynamics techniques and in other populations (e.g. peripheral neuropathies). Level of evidence III. PMID:29387655

  3. Time-to-impact estimation in passive missile warning systems

    NASA Astrophysics Data System (ADS)

    Şahıngıl, Mehmet Cihan

    2017-05-01

    A missile warning system can detect the incoming missile threat(s) and automatically cue the other Electronic Attack (EA) systems in the suit, such as Directed Infrared Counter Measure (DIRCM) system and/or Counter Measure Dispensing System (CMDS). Most missile warning systems are currently based on passive sensor technology operating in either Solar Blind Ultraviolet (SBUV) or Midwave Infrared (MWIR) bands on which there is an intensive emission from the exhaust plume of the threatening missile. Although passive missile warning systems have some clear advantages over pulse-Doppler radar (PDR) based active missile warning systems, they show poorer performance in terms of time-to-impact (TTI) estimation which is critical for optimizing the countermeasures and also "passive kill assessment". In this paper, we consider this problem, namely, TTI estimation from passive measurements and present a TTI estimation scheme which can be used in passive missile warning systems. Our problem formulation is based on Extended Kalman Filter (EKF). The algorithm uses the area parameter of the threat plume which is derived from the used image frame.

  4. Intercomparison of active and passive instruments for radon and radon progeny in North America

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    George, A.C.; Tu, Keng-Wu; Knutson, E.O.

    1995-02-01

    An intercomparison exercise for radon and radon progeny instruments and methods was held at the Environmental Measurements Laboratory (EML) from April 22--May 2, 1994. The exercise was conducted in the new EML radon test and calibration facility in which conditions of exposure are very well controlled. The detection systems of the intercompared instruments consisted of. (1) pulse ionization chambers, (2) electret ionization chambers, (3) scintillation detectors, (4) alpha particle spectrometers with silicon diodes, surface barrier or diffused junction detectors, (5) registration of nuclear tracks in solid-state materials, and (6) activated carbon collectors counted by gamma-ray spectrometry or by alpha- andmore » beta-liquid scintillation counting. 23 private firms, government laboratories and universities participated with a 165 passive integrating devices consisting of: Activated carbon collectors, nuclear alpha track detectors and electret ionization chambers, and 11 active and passive continuous radon monitors. Five portable integrating and continuous instruments were intercompared for radon progeny. Forty grab samples for radon progeny were taken by five groups that participated in person to test and evaluate their primary instruments and methods that measure individual radon progeny and the potential alpha energy concentration (PAEC) in indoor air. Results indicate that more than 80% of the measurements for radon performed with a variety of instruments, are within {plus_minus}10% of actual value. The majority of the instruments that measure individual radon progeny and the PAEC gave results that are in good agreement with the EML reference value. Radon progeny measurements made with continuous and integrating instruments are satisfactory with room for improvement.« less

  5. A family of asymptotically stable control laws for flexible robots based on a passivity approach

    NASA Technical Reports Server (NTRS)

    Lanari, Leonardo; Wen, John T.

    1991-01-01

    A general family of asymptotically stabilizing control laws is introduced for a class of nonlinear Hamiltonian systems. The inherent passivity property of this class of systems and the Passivity Theorem are used to show the closed-loop input/output stability which is then related to the internal state space stability through the stabilizability and detectability condition. Applications of these results include fully actuated robots, flexible joint robots, and robots with link flexibility.

  6. Modelling and study of active vibration control for off-road vehicle

    NASA Astrophysics Data System (ADS)

    Zhang, Junwei; Chen, Sizhong

    2014-05-01

    In view of special working characteristics and structure, engineering machineries do not have conventional suspension system typically. Consequently, operators have to endure severe vibrations which are detrimental both to their health and to the productivity of the loader. Based on displacement control, a kind of active damping method is developed for a skid-steer loader. In this paper, the whole hydraulic system for active damping method is modelled which include swash plate dynamics model, proportional valve model, piston accumulator model, pilot-operated check valve model, relief valve model, pump loss model, and cylinder model. A new road excitation model is developed for the skid-steer loader specially. The response of chassis vibration acceleration to road excitation is verified through simulation. The simulation result of passive accumulator damping is compared with measurements and the comparison shows that they are close. Based on this, parallel PID controller and track PID controller with acceleration feedback are brought into the simulation model, and the simulation results are compared with passive accumulator damping. It shows that the active damping methods with PID controllers are better in reducing chassis vibration acceleration and pitch movement. In the end, the test work for active damping method is proposed for the future work.

  7. Long-term performance of the passive thermal control systems of the IRAS spacecraft

    NASA Technical Reports Server (NTRS)

    Mason, P. V.

    1988-01-01

    Degradation of passive thermal control systems in space is a matter of serious concern and has been observed in many missions. The performance of the passive thermal control systems of the Infrared Astronomical Satellite (IRAS) over a period of three years is reported here. An exterior temperature of 200 K and a sunshade temperature of approximately 100 K were maintained over this period without significant degradation. The temperature of the telescope contained in the IRAS cryostat was also observed for two years after expenditure of the helium cryogen. It remained at 100 K with no degradation.

  8. A comparative analysis of passive twin tube and skyhook MRF dampers for motorcycle front suspensions

    NASA Astrophysics Data System (ADS)

    Ahmadian, Mehdi; Gravatt, John

    2004-07-01

    A comparative analysis between conventional passive twin tube dampers and skyhook-controlled magneto-rheological fluid (MRF) dampers for motorcycle front suspensions is provided, based on single axis testing in a damper test rig and suspension performance testing in road trials. Performance motorcycles, while boasting extremely light suspension components and competition-ready performance, have an inherent weakness in comfort, as the suspension systems are designed primarily for racing purposes. Front suspension acceleration and shock loading transmit directly through the front suspension triple clamp into the rider's arms and shoulders, causing rapid fatigue in shoulder muscles. Magneto-rheological fluid dampers and skyhook control systems offer an alternative to conventional sport motorcycle suspensions - both performance and comfort can be combined in the same package. Prototype MRF dampers designed and manufactured specifically for this application require no more space than conventional twin tube designs while adding only 1.7 pounds total weight to the system. The MRF dampers were designed for high controllability and low power consumption, two vital considerations for a motorcycle application. The tests conducted include the dampers' force-velocity curve testing in a damper test rig and suspension performance based on damper position, velocity, and acceleration measurement. Damper test rig results show the MRF dampers have a far greater range of adjustability than the test vehicle's OEM dampers. Combined with a modified sky-hook control system, the MRF dampers can greatly decrease the acceleration and shock loading transmitted to the rider through the handlebars while contributing performance in manners such as anti-dive under braking. Triple clamp acceleration measurements from a variety of staged road conditions, such as sinusoidal wave inputs, will be compared to subjective test-rider field reports to establish a correlation between rider fatigue and the front suspension performance. This testing will be conducted on the OEM vehicle suspension, the passive MRF dampers, and the skyhook-controlled MRF damper front suspension. The results of this test will determine the viability of skyhook-controlled MRF damper systems on motorcycles for performance gain and fatigue reduction.

  9. Acute Lower Extremity Running Kinematics After a Hamstring Stretch

    PubMed Central

    Davis Hammonds, Autumn L.; Laudner, Kevin G.; McCaw, Steve; McLoda, Todd A.

    2012-01-01

    Context: Limited passive hamstring flexibility might affect kinematics, performance, and injury risk during running. Pre-activity static straight-leg raise stretching often is used to gain passive hamstring flexibility. Objective: To investigate the acute effects of a single session of passive hamstring stretching on pelvic, hip, and knee kinematics during the swing phase of running. Design: Randomized controlled clinical trial. Setting: Biomechanics research laboratory. Patients or Other Participants: Thirty-four male (age = 21.2 ± 1.4 years) and female (age = 21.3±2.0 years) recreational athletes. Intervention(s): Participants performed treadmill running pretests and posttests at 70% of their age-predicted maximum heart rate. Pelvis, hip, and knee joint angles during the swing phase of 5 consecutive gait cycles were collected using a motion analysis system. Right and left hamstrings of the intervention group participants were passively stretched 3 times for 30 seconds in random order immediately after the pretest. Control group participants performed no stretching or movement between running sessions. Main Outcome Measure(s): Six 2-way analyses of variance to determine joint angle differences between groups at maximum hip flexion and maximum knee extension with an α level of .008. Results: Flexibility increased between pretest and post-test in all participants (F1,30 = 80.61, P<.001). Anterior pelvic tilt (F1,30 = 0.73, P=.40), hip flexion (F1,30 = 2.44, P=.13), and knee extension (F1,30 = 0.06, P=.80) at maximum hip flexion were similar between groups throughout testing. Anterior pelvic tilt (F1,30 = 0.69, P=.41), hip flexion (F1,30 = 0.23, P=.64), and knee extension (F1,30 = 3.38, P=.62) at maximum knee extension were similar between groups throughout testing. Men demonstrated greater anterior pelvic tilt than women at maximum knee extension (F1,30 = 13.62, P=.001). Conclusions: A single session of 3 straight-leg raise hamstring stretches did not change pelvis, hip, or knee running kinematics. PMID:22488225

  10. Acute effects of electronic and tobacco cigarette smoking on complete blood count.

    PubMed

    Flouris, Andreas D; Poulianiti, Konstantina P; Chorti, Maria S; Jamurtas, Athanasios Z; Kouretas, Dimitrios; Owolabi, Emmanuel O; Tzatzarakis, Manolis N; Tsatsakis, Aristidis M; Koutedakis, Yiannis

    2012-10-01

    The World Health Organisation called for research assessing the safety of electronic cigarette (e-cigarette). We evaluated the acute effect of active and passive e-cigarette and tobacco cigarette smoking on complete blood count (CBC) markers in 15 smokers and 15 never-smokers, respectively. Smokers underwent a control session, an active tobacco cigarette smoking session, and an active e-cigarette smoking session. Never-smokers underwent a control session, a passive tobacco cigarette smoking session, and a passive e-cigarette smoking session. The results demonstrated that CBC indices remained unchanged during the control session and the active and passive e-cigarette smoking sessions (P>0.05). Active and passive tobacco cigarette smoking increased white blood cell, lymphocyte, and granulocyte counts for at least one hour in smokers and never smokers (P<0.05). It is concluded that acute active and passive smoking using the e-cigarettes tested in the current study does not influence CBC indices in smokers and never smokers, respectively. In contrast, acute active and passive tobacco cigarette smoking increase the secondary proteins of acute inflammatory load for at least one hour. More research is needed to evaluate chemical safety issues and other areas of consumer product safety of e-cigarettes, because the nicotine content in the liquids used may vary considerably. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. Effects of Functional Training and Calf Stretching on Risk of Falls in Older People: A Pilot Study.

    PubMed

    do Rosario, Jailton Thulher; da Fonseca Martins, Natalia Santos; Peixinho, Carolina Carneiro; Oliveira, Liliam Fernandes

    2017-04-01

    This study aimed to determine the effects of a functional training and ankle stretching program in triceps surae torque, passive stiffness index, and in the risk for fall indicators in older adults. Twenty women (73.4 ± 7.3 years) were allocated into an intervention or control group. The 12-week intervention consisted of functional training and calf stretching exercises performed twice a week. Measurements of peak passive and active torque, passive stiffness, maximum dorsiflexion angle, and indexes of risk for falls (Timed Up and Go, functional reach test, QuickScreen-test) were collected. There were no significant differences for all variables, except the maximum dorsiflexion angle, which increased in the intervention group from 33.78 ± 8.57° to 38.89 ± 7.52°. The exercise program was not sufficient to enhance performance on functional tests and decrease the risk for falls in older adults. The significant increase in the maximum dorsiflexion indicates a positive impact of stretching exercises.

  12. Prediction of primary somatosensory neuron activity during active tactile exploration

    PubMed Central

    Campagner, Dario; Evans, Mathew Hywel; Bale, Michael Ross; Erskine, Andrew; Petersen, Rasmus Strange

    2016-01-01

    Primary sensory neurons form the interface between world and brain. Their function is well-understood during passive stimulation but, under natural behaving conditions, sense organs are under active, motor control. In an attempt to predict primary neuron firing under natural conditions of sensorimotor integration, we recorded from primary mechanosensory neurons of awake, head-fixed mice as they explored a pole with their whiskers, and simultaneously measured both whisker motion and forces with high-speed videography. Using Generalised Linear Models, we found that primary neuron responses were poorly predicted by whisker angle, but well-predicted by rotational forces acting on the whisker: both during touch and free-air whisker motion. These results are in apparent contrast to previous studies of passive stimulation, but could be reconciled by differences in the kinematics-force relationship between active and passive conditions. Thus, simple statistical models can predict rich neural activity elicited by natural, exploratory behaviour involving active movement of sense organs. DOI: http://dx.doi.org/10.7554/eLife.10696.001 PMID:26880559

  13. Sensorless Load Torque Estimation and Passivity Based Control of Buck Converter Fed DC Motor

    PubMed Central

    Kumar, S. Ganesh; Thilagar, S. Hosimin

    2015-01-01

    Passivity based control of DC motor in sensorless configuration is proposed in this paper. Exact tracking error dynamics passive output feedback control is used for stabilizing the speed of Buck converter fed DC motor under various load torques such as constant type, fan type, propeller type, and unknown load torques. Under load conditions, sensorless online algebraic approach is proposed, and it is compared with sensorless reduced order observer approach. The former produces better response in estimating the load torque. Sensitivity analysis is also performed to select the appropriate control variables. Simulation and experimental results fully confirm the superiority of the proposed approach suggested in this paper. PMID:25893208

  14. Deep influence of passive low energy consumption multi-storey residential building in cold region

    NASA Astrophysics Data System (ADS)

    Shuai, Zhang; Lihua, Zhao; Rong, Jin; Dong, Junyan

    2018-02-01

    The example of passive architecture demonstration building in Jilin Province, China, based on the practical experience of this project, the control index of passive and low energy consumption residential buildings in cold and passive buildings is referenced by reference to the German construction standard and the Chinese residence construction document, “passive ultra-low energy consumption green Building Technology Guide (Trial)”. The requirement of passive low energy residential buildings on the ground heat transfer coefficient limits is determined, and the performance requirements of passive residential buildings are discussed. This paper analyzes the requirement of the passive low energy residential building on the ground heat transfer coefficient limit, and probes into the influence factors of the ground thermal insulation of the passive low energy consumption residential building. The construction method of passive low energy consumption residential building is proposed.

  15. Laser Pyrometer For Spot Temperature Measurements

    NASA Technical Reports Server (NTRS)

    Elleman, D. D.; Allen, J. L.; Lee, M. C.

    1988-01-01

    Laser pyrometer makes temperature map by scanning measuring spot across target. Scanning laser pyrometer passively measures radiation emitted by scanned spot on target and calibrated by similar passive measurement on blackbody of known temperature. Laser beam turned on for active measurements of reflectances of target spot and reflectance standard. From measurements, temperature of target spot inferred. Pyrometer useful for non-contact measurement of temperature distributions in processing of materials.

  16. Hydrogen passivation of polycrystalline silicon thin films

    NASA Astrophysics Data System (ADS)

    Scheller, L.-P.; Weizman, M.; Simon, P.; Fehr, M.; Nickel, N. H.

    2012-09-01

    The influence of post-hydrogenation on the electrical and optical properties of solid phase crystallized polycrystalline silicon (poly-Si) was examined. The passivation of grain-boundary defects was measured as a function of the passivation time. The silicon dangling-bond concentration decreases with increasing passivation time due to the formation of Si-H complexes. In addition, large H-stabilized platelet-like clusters are generated. The influence of H on the electrical properties was investigated using temperature dependent conductivity and Hall-effect measurements. For poly-Si on Corning glass, the dark conductivity decreases upon hydrogenation, while it increases when the samples are fabricated on silicon-nitride covered Borofloat glass. Hall-effect measurements reveal that for poly-Si on Corning glass the hole concentration and the mobility decrease upon post-hydrogenation, while a pronounced increase is observed for poly-Si on silicon-nitride covered Borofloat glass. This indicates the formation of localized states in the band gap, which is supported by sub band-gap absorption measurments. The results are discussed in terms of hydrogen-induced defect passivation and generation mechanisms.

  17. Trapping behavior of Shockley-Read-Hall recombination centers in silicon solar cells

    NASA Astrophysics Data System (ADS)

    Gogolin, R.; Harder, N. P.

    2013-08-01

    We investigate the correlation between increased apparent carrier lifetime in photoconductance-based lifetime measurements and actually reduced recombination lifetime as measured by photoluminescence measurements. These findings are further reconfirmed by I-V curve measurements of solar cells. In particular, we show experimental results for lifetime samples and solar cells with and without hydrogen passivation. In the samples and solar cells without hydrogen passivation, we find both a stronger trapping behavior and a lower recombination lifetime. Our model provides a consistent description of the observation of both, the increased apparent lifetime from carrier trapping and the decreasing recombination lifetime. In our model, both are caused by a single physical mechanism; i.e., by Recombination-Active-Trap (RAT) states. Upon fitting the experimental lifetime data, we find that the RAT-defect parameters for the hydrogen-passivated and non-hydrogen-passivated lifetime samples and solar cells are identical except for the defect concentration: hydrogen-passivation reduced the defect density by 50% in both, the lifetime samples and solar cells. We conclude that trapping should be considered as an indication for hidden, yet potentially strongly increased, low injection recombination activity.

  18. Comparing the Effects of Peroneal Muscle Fatigue and Cyclic Loading on Ankle Neuromuscular Control During Lateral-Hop Landing.

    PubMed

    Malmir, Kazem; Olyaei, Gholam Reza; Talebian, Saeed; Jamshidi, Ali Ashraf

    2015-08-01

    Cyclic movements and muscle fatigue may result in musculoskeletal injuries by inducing changes in neuromuscular control. Ankle frontal-plane neuromuscular control has rarely been studied in spite of its importance. To compare the effects of peroneal muscle fatigue and a cyclic passive-inversion (CPI) protocol on ankle neuromuscular control during a lateral hop. Quasi-experimental, repeated measures. University laboratory. 22 recreationally active, healthy men with no history of ankle sprain or giving way. Participants performed a lateral hop before and after 2 interventions on a Biodex dynamometer. They were randomly assigned to intervention order and interventions were 1 wk apart. A passive intervention included 40 CPIs at 5°/s through 80% of maximum range of motion, and a fatigue intervention involved an isometric eversion at 40% of the maximal voluntary isometric contraction until the torque decreased to 50% of its initial value. Median frequency of the peroneus longus during the fatigue protocol, energy absorption by the viscoelastic tissues during the CPI protocol, and feedforward onset and reaction time of the peroneus longus during landing. A significant fall in median frequency (P < .05) and a significant decrease in energy absorption (P < .05) confirmed fatigue and a change in viscoelastic behavior, respectively. There was a significant main effect of condition on feedforward onset and reaction time (P < .05). No significant main effect of intervention or intervention × condition interaction was noted (P > .05). There was a significant difference between pre- and postintervention measures (P < .0125), but no significant difference was found between postintervention measures (P > .0125). Both fatigue and the CPI may similarly impair ankle neuromuscular control. Thus, in prolonged sports competitions and exercises, the ankle may be injured due to either fatigue or changes in the biomechanical properties of the viscoelastic tissues.

  19. Comparative Measurements of Radon Concentration in Soil Using Passive and Active Methods in High Level Natural Radiation Area (HLNRA) of Ramsar

    PubMed Central

    Amanat, B; Kardan, M R; Faghihi, R; Hosseini Pooya, S M

    2013-01-01

    Background: Radon and its daughters are amongst the most important sources of natural exposure in the world. Soil is one of the significant sources of radon/thoron due to both radium and thorium so that the emanated thoron from it may cause increased uncertainties in radon measurements. Recently, a diffusion chamber has been designed and optimized for passive discriminative measurements of radon/thoron concentrations in soil. Objective: In order to evaluate the capability of the passive method, some comparative measurements (with active methods) have been performed. Method: The method is based upon measurements by a diffusion chamber, including two Lexan polycarbonate SSNTDs, which can discriminate the emanated radon/thorn from the soil by delay method. The comparative measurements have been done in ten selected points of HLNRA of Ramsar in Iran. The linear regression and correlation between the results of two methods have been studied. Results: The results show that the radon concentrations are within the range of 12.1 to 165 kBq/m3 values. The correlation between the results of active and passive methods was measured by 0.99 value. As well, the thoron concentrations have been measured between 1.9 to 29.5 kBq/m3 values at the points. Conclusion: The sensitivity as well as the strong correlation with active measurements shows that the new low-cost passive method is appropriate for accurate seasonal measurements of radon and thoron concentration in soil. PMID:25505760

  20. Measurement of gastrocnemius muscle elasticity by shear wave elastography: association with passive ankle joint stiffness and sex differences.

    PubMed

    Chino, Kentaro; Takahashi, Hideyuki

    2016-04-01

    Passive joint stiffness is an important quantitative measure of flexibility, but is affected by muscle volume and all of the anatomical structures located within and over the joint. Shear wave elastography can assess muscle elasticity independent of the influences of muscle volume and the other nearby anatomical structures. We determined how muscle elasticity, as measured using shear wave elastography, is associated with passive joint stiffness and patient sex. Twenty-six healthy men (24.4 ± 5.9 years) and 26 healthy women (25.2 ± 4.8 years) participated in this study. The passive ankle joint stiffness and tissue elasticity of the medial gastrocnemius (MG) were quantified with the ankle in 30° plantar flexion (PF), a neutral anatomical position (NE), and 20° dorsiflexion (DF). No significant difference in passive joint stiffness by sex was observed with the ankle in PF, but significantly greater passive ankle joint stiffness in men than in women was observed in NE and DF. The MG elasticity was not significantly associated with joint stiffness in PF or NE, but it was significantly associated with joint stiffness in DF. There were no significant differences in MG elasticity by sex at any ankle position. Muscle elasticity, measured independent of the confounding effects of muscle volume and the other nearby anatomical structures, is associated with passive joint stiffness in the joint position where the muscle is sufficiently lengthened, but does not vary by sex in any joint position tested.

  1. Adaptive Structures Programs for the Strategic Defense Initiative Organization

    DTIC Science & Technology

    1992-01-01

    Advanced Control Technology Experiment ( ACTEX ) Modular Control Patch High Frequency Passive Damping Strut Development Optional PZT Passive...on this space test bed in FY95. The Advanced Control Technology Experiment ( ACTEX ) will demonstrate many of the adaptive structures technologies...Accelerometer Bi-ax Accelerometer Smart Strut Figure 7. Schematic of Advanced Control Technology Experiment ( ACTEX ) 6-28-91-2M 1-6-92-5M PZ Stack

  2. Aspects and Some Results on Passivity and Positivity of Dynamic Systems

    NASA Astrophysics Data System (ADS)

    De la Sen, M.

    2017-12-01

    This paper is devoted to discuss certain aspects of passivity results in dynamic systems and the characterization of the regenerative systems counterparts. In particular, the various concepts of passivity as standard passivity, strict input passivity, strict output passivity and very strict passivity (i.e. joint strict input and output passivity) are given and related to the existence of a storage function and a dissipation function. Later on, the obtained results are related to external positivity of systems and positivity or strict positivity of the transfer matrices and transfer functions in the time-invariant case. On the other hand, it is discussed how to achieve or how eventually to increase the passivity effects via linear feedback by the synthesis of the appropriate feed-forward or feedback controllers or, simply, by adding a positive parallel direct input-output matrix interconnection gain.

  3. Contribution of titin and extracellular matrix to passive pressure and measurement of sarcomere length in the mouse left ventricle

    PubMed Central

    Chung, Charles S; Granzier, Henk L

    2011-01-01

    It remains to be established to what degree titin and the extracellular matrix (ECM) contribute to passive pressure in the left ventricle (LV). Thus, we aimed to elucidate the contribution of major molecular determinants of passive pressure in the normal mouse LV. Furthermore, we determined the working sarcomere length (SL) range of the LV to bridge our findings to earlier work in skinned muscle fibers. We utilized Frank-Starling type protocols to obtain diastolic pressure-volume relationships (PVR) in Langendorff perfused isolated LVs. To quantify the molecular contribution of titin and ECM, we innovated on methods of fiber mechanics to chemically permeabilize intact LVs and measure a fully passive PVR. To differentially dissect the contributions of the ECM and titin, we utilized myofilament extraction techniques in permeabilized LVs, measuring passive PVRs at each stage in the protocol. Myofilament extraction suggests that titin contributes ~80% of passive pressures in the heart. Langendorff perfusion was also used to chemically fix passive and BaCl2 activated hearts at specific volumes to determine that the maximal working SL range of the midwall LV fibers is approximately 1.8-2.2 μm. A model of the passive SL-Volume relationship was then used to estimate the pressure-SL relationships, indicating that the ECM contribution does not exceed titin's contribution until large volumes with SLs>~2.2μm. In conclusion, within physiological volumes titin is the dominant contributor to LV passive pressure, and ECM-based pressures dominates at larger volumes. PMID:21255582

  4. Active/Passive Control of Sound Radiation from Panels using Constrained Layer Damping

    NASA Technical Reports Server (NTRS)

    Gibbs, Gary P.; Cabell, Randolph H.

    2003-01-01

    A hybrid passive/active noise control system utilizing constrained layer damping and model predictive feedback control is presented. This system is used to control the sound radiation of panels due to broadband disturbances. To facilitate the hybrid system design, a methodology for placement of constrained layer damping which targets selected modes based on their relative radiated sound power is developed. The placement methodology is utilized to determine two constrained layer damping configurations for experimental evaluation of a hybrid system. The first configuration targets the (4,1) panel mode which is not controllable by the piezoelectric control actuator, and the (2,3) and (5,2) panel modes. The second configuration targets the (1,1) and (3,1) modes. The experimental results demonstrate the improved reduction of radiated sound power using the hybrid passive/active control system as compared to the active control system alone.

  5. Terahertz-bandwidth coherence measurements of a quantum dash laser in passive and active mode-locking operation.

    PubMed

    Martin, Eamonn; Watts, Regan; Bramerie, Laurent; Shen, Alexandre; Gariah, Harry; Blache, Fabrice; Lelarge, Francois; Barry, Liam

    2012-12-01

    This research carries out coherence measurements of a 42.7 GHz quantum dash (QDash) semiconductor laser when passively, electrically, and optically mode-locked. Coherence of the spectral lines from the mode-locked laser is determined by examining the radio frequency beat-tone linewidth as the mode spacing is increased up to 1.1 THz. Electric-field measurements of the QDash laser are also presented, from which a comparison between experimental results and accepted theory for coherence in passively mode-locked lasers has been performed.

  6. Local-Level Prognostics Health Management Systems Framework for Passive AdvSMR Components. Interim Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ramuhalli, Pradeep; Roy, Surajit; Hirt, Evelyn H.

    2014-09-12

    This report describes research results to date in support of the integration and demonstration of diagnostics technologies for prototypical AdvSMR passive components (to establish condition indices for monitoring) with model-based prognostics methods. The focus of the PHM methodology and algorithm development in this study is at the localized scale. Multiple localized measurements of material condition (using advanced nondestructive measurement methods), along with available measurements of the stressor environment, enhance the performance of localized diagnostics and prognostics of passive AdvSMR components and systems.

  7. Cigarettes vs. e-cigarettes: Passive exposure at home measured by means of airborne marker and biomarkers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ballbè, Montse; Catalan Network of Smoke-free Hospitals, L'Hospitalet de Llobregat, Barcelona; Cancer Prevention and Control Group, Institut d'Investigació Biomèdica de Bellvitge – IDIBELL, L’Hospitalet de Llobregat, Barcelona

    Background: There is scarce evidence about passive exposure to the vapour released or exhaled from electronic cigarettes (e-cigarettes) under real conditions. The aim of this study is to characterise passive exposure to nicotine from e-cigarettes' vapour and conventional cigarettes' smoke at home among non-smokers under real-use conditions. Methods: We conducted an observational study with 54 non-smoker volunteers from different homes: 25 living at home with conventional smokers, 5 living with nicotine e-cigarette users, and 24 from control homes (not using conventional cigarettes neither e-cigarettes). We measured airborne nicotine at home and biomarkers (cotinine in saliva and urine). We calculated geometricmore » mean (GM) and geometric standard deviations (GSD). We also performed ANOVA and Student's t tests for the log-transformed data. We used Bonferroni-corrected t-tests to control the family error rate for multiple comparisons at 5%. Results: The GMs of airborne nicotine were 0.74 μg/m{sup 3} (GSD=4.05) in the smokers’ homes, 0.13 μg/m{sup 3} (GSD=2.4) in the e-cigarettes users’ homes, and 0.02 μg/m{sup 3} (GSD=3.51) in the control homes. The GMs of salivary cotinine were 0.38 ng/ml (GSD=2.34) in the smokers’ homes, 0.19 ng/ml (GSD=2.17) in the e-cigarettes users’ homes, and 0.07 ng/ml (GSD=1.79) in the control homes. Salivary cotinine concentrations of the non-smokers exposed to e-cigarette's vapour at home (all exposed ≥2 h/day) were statistically significant different that those found in non-smokers exposed to second-hand smoke ≥2 h/day and in non-smokers from control homes. Conclusions: The airborne markers were statistically higher in conventional cigarette homes than in e-cigarettes homes (5.7 times higher). However, concentrations of both biomarkers among non-smokers exposed to conventional cigarettes and e-cigarettes’ vapour were statistically similar (only 2 and 1.4 times higher, respectively). The levels of airborne nicotine and cotinine concentrations in the homes with e-cigarette users were higher than control homes (differences statistically significant). Our results show that non-smokers passively exposed to e-cigarettes absorb nicotine. - Highlights: • This is the first study of e-cigarette exposure at home under real-use conditions. • Airborne nicotine in homes with smokers were 5.7 times higher than in e-cig homes. • Cotinine of non-smokers exposed to e-cig and conventional cigarettes was similar. • Airborne nicotine in homes with e-cig users was higher than control homes. • Cotinine of non-smokers exposed to e-cig users was higher than in those no exposed.« less

  8. Preliminary design of a simple passive toe exercise apparatus with a flexible metal hydride actuator for pressure ulcer prevention.

    PubMed

    Ino, Shuichi; Sato, Mitsuru; Hosono, Minako; Nakajima, Sawako; Yamashita, Kazuhiko; Izumi, Takashi

    2010-01-01

    In an aging society, social demands for home-based rehabilitation and assistive technologies by healthcare and welfare services are globally increasing. The progress of quality-of-life technologies and rehabilitation science is a very important and urgent issue for elderly and disabled individuals as well as for their caregivers. Thus, there is a substantial need to develop simple bedside apparatuses for both continuous exercise of joints and for power assistance for standing to prevent and manage disuse syndromes (e.g., pressure ulcers, joint contractures and muscular atrophy). Unfortunately, there are currently no commercially-available actuators compatible with the human requirements of flexibility, quietness, lightness and a high power-to-weight ratio. To fulfill the above demands, we have developed a novel actuation device using a metal hydride (MH) alloy and a laminate film, called the flexible MH actuator, as a human-friendly force generator for healthcare and welfare services. In this paper, we show the basic structure and characteristics of the flexible MH actuator used to create a passive exercise system for preventing disuse syndromes. To evaluate the efficiency of passive exercise for bedsore prevention, subcutaneous blood flow during passive exercise at common pressure-ulcer sites is measured by a laser blood flow meter. The force and range-of-motion angle required for a passive exercise apparatus is also examined with the help of a professional physical therapist. Based on these findings, a prototype of a passive exercise apparatus is fabricated using the flexible MH actuator technology, and its operation characteristics are preliminarily verified using a thermoelectric control system.

  9. The Effect of Patella Eversion on Clinical Outcome Measures in Simultaneous Bilateral Total Knee Arthroplasty: A Prospective Randomized Controlled Trial.

    PubMed

    Zan, Pengfei; Wu, Zhong; Yu, Xiao; Fan, Lin; Xu, Tianyang; Li, Guodong

    2016-03-01

    During total knee arthroplasty (TKA), surgical exposure requires mobilization technique of the patella. With this trial, we intended to investigate the effect of patella eversion on clinical outcome measures in simultaneous bilateral TKA. We prospectively enrolled 44 patients (88 knees) from April 2008 to June 20l4.One knee was operated with patella eversion (group A) and the other with patella lateral retraction (group B) randomly. Follow-up results, including the operation time, complications, and the time of achieving straight leg raise (SLR) and 90° knee flexion, were recorded. The data of range of motion (ROM) and Visual Analogue Scale score were collected separately at 7 days, 3 months, 6 months, and 1 year postoperatively. The time of achieving SLR was 2.7 ± 0.8 days in group A and 2.1 ± 0.7 DAYS in group B, which were significantly different (P = .032). Significant difference was found on active and passive ROM during the follow-up times between groups A and B, except the passive ROM at 6 months postoperatively. No significant difference was found on operation time, complications, patella baja or tilt, time of achieving 90°knee flexion, and Visual Analogue Scale score during the follow-up times. Patellar eversion was adverse to the early knee function recovery after TKA; it would delay the time of achieving SLR and decrease the passive and active ROM. In addition, more carefully and scientifically designed randomized controlled trials are still required to further prove the claim. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Effect of long-term isometric training on core/torso stiffness.

    PubMed

    Lee, Benjamin C Y; McGill, Stuart M

    2015-06-01

    Although core stiffness enhances athletic performance traits, controversy exists regarding the effectiveness of isometric vs. dynamic core training methods. This study aimed to determine whether long-term changes in stiffness can be trained, and if so, what is the most effective method. Twenty-four healthy male subjects (23 ± 3 years; 1.8 ± 0.06 m; 77.5 ± 10.8 kg) were recruited for passive and active stiffness measurements before and after a 6-week core training intervention. Twelve subjects (22 ± 2 years; 1.8 ± 0.08 m; 78.3 ± 12.3 kg) were considered naive to physical and core exercise. The other 12 subjects (24 ± 3 years; 1.8 ± 0.05 m; 76.8 ± 9.7 kg) were Muay Thai athletes (savvy). A repeated-measures design compared core training methods (isometric vs. dynamic, with a control group) and subject training experience (naive vs. savvy) before and after a 6-week training period. Passive stiffness was assessed on a "frictionless" bending apparatus and active stiffness assessed through a quick release mechanism. Passive stiffness increased after the isometric training protocol. Dynamic training produced a smaller effect, and as expected, there was no change in the control group. Active stiffness did not change in any group. Comparisons between subject and training groups did not reveal any interactions. Thus, an isometric training approach was superior in terms of enhancing core stiffness. This is important since increased core stiffness enhances load bearing ability, arrests painful vertebral micromovements, and enhances ballistic distal limb movement. This may explain the efficacy reported for back and knee injury reduction.

  11. Comparison between active (pumped) and passive (diffusive) sampling methods for formaldehyde in pathology and histology laboratories.

    PubMed

    Lee, Eun Gyung; Magrm, Rana; Kusti, Mohannad; Kashon, Michael L; Guffey, Steven; Costas, Michelle M; Boykin, Carie J; Harper, Martin

    2017-01-01

    This study was to determine occupational exposures to formaldehyde and to compare concentrations of formaldehyde obtained by active and passive sampling methods. In one pathology and one histology laboratories, exposure measurements were collected with sets of active air samplers (Supelco LpDNPH tubes) and passive badges (ChemDisk Aldehyde Monitor 571). Sixty-six sample pairs (49 personal and 17 area) were collected and analyzed by NIOSH NMAM 2016 for active samples and OSHA Method 1007 (using the manufacturer's updated uptake rate) for passive samples. All active and passive 8-hr time-weighted average (TWA) measurements showed compliance with the OSHA permissible exposure limit (PEL-0.75 ppm) except for one passive measurement, whereas 78% for the active and 88% for the passive samples exceeded the NIOSH recommended exposure limit (REL-0.016 ppm). Overall, 73% of the passive samples showed higher concentrations than the active samples and a statistical test indicated disagreement between two methods for all data and for data without outliers. The OSHA Method cautions that passive samplers should not be used for sampling situations involving formalin solutions because of low concentration estimates in the presence of reaction products of formaldehyde and methanol (a formalin additive). However, this situation was not observed, perhaps because the formalin solutions used in these laboratories included much less methanol (3%) than those tested in the OSHA Method (up to 15%). The passive samplers in general overestimated concentrations compared to the active method, which is prudent for demonstrating compliance with an occupational exposure limit, but occasional large differences may be a result of collecting aerosolized droplets or splashes on the face of the samplers. In the situations examined in this study the passive sampler generally produces higher results than the active sampler so that a body of results from passive samplers demonstrating compliance with the OSHA PEL would be a valid conclusion. However, individual passive samples can show lower results than a paired active sampler so that a single result should be treated with caution.

  12. Distributed structural control using multilayered piezoelectric actuators

    NASA Technical Reports Server (NTRS)

    Cudney, Harley H.; Inman, Daniel J.; Oshman, Yaakov

    1990-01-01

    A method of segmenting piezoelectric sensors and actuators is proposed which can preclude the currently experienced cancelation of sensor signals, or the reduction of actuator effectiveness, due to the integration of the property undergoing measurement or control. The segmentation method is demonstrated by a model developed for beam structures, to which multiple layers of piezoelectric materials are attached. A numerical study is undertaken of increasing active and passive damping of a beam using the segmented sensors and actuators over unsegmented sensors and actuators.

  13. Jet outflow and open field line measurements on the C-2U advanced beam-driven field-reversed configuration plasma experiment.

    PubMed

    Sheftman, D; Gupta, D; Roche, T; Thompson, M C; Giammanco, F; Conti, F; Marsili, P; Moreno, C D

    2016-11-01

    Knowledge and control of the axial outflow of plasma particles and energy along open-magnetic-field lines are of crucial importance to the stability and longevity of the advanced beam-driven field-reversed configuration plasma. An overview of the diagnostic methods used to perform measurements on the open field line plasma on C-2U is presented, including passive Doppler impurity spectroscopy, microwave interferometry, and triple Langmuir probe measurements. Results of these measurements provide the jet ion temperature and axial velocity, electron density, and high frequency density fluctuations.

  14. Effect of space exposure on pyroelectric infrared detectors

    NASA Technical Reports Server (NTRS)

    Robertson, James B.; Clark, Ivan O.

    1991-01-01

    Twenty pyroelectric type infrared detectors were flown onboard the Long Duration Exposure Facility (LDEF). The detector chips were of three different pyroelectric materials: lithium-tantalate, strontium-barium-niobate, and triglycine-sulfide. The experiment was passive; no measurements were taken during the flight. Performance of the detectors was measured before and after flight. Postflight measurements revealed that detectors made of lithium-tantalate and strontium-barium-niobate suffered no measureable loss in performance. Detectors made of triglycine-sulfide suffered complete loss of performance, but so did the control samples of the same material. Repoling of the triglycine-sulfide failed to revive the detectors.

  15. Jet outflow and open field line measurements on the C-2U advanced beam-driven field-reversed configuration plasma experiment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheftman, D., E-mail: dsheftman@trialphaenergy.com; Gupta, D.; Roche, T.

    Knowledge and control of the axial outflow of plasma particles and energy along open-magnetic-field lines are of crucial importance to the stability and longevity of the advanced beam-driven field-reversed configuration plasma. An overview of the diagnostic methods used to perform measurements on the open field line plasma on C-2U is presented, including passive Doppler impurity spectroscopy, microwave interferometry, and triple Langmuir probe measurements. Results of these measurements provide the jet ion temperature and axial velocity, electron density, and high frequency density fluctuations.

  16. Music chills: The eye pupil as a mirror to music's soul.

    PubMed

    Laeng, Bruno; Eidet, Lise Mette; Sulutvedt, Unni; Panksepp, Jaak

    2016-08-01

    This study evaluated whether music-induced aesthetic "chill" responses, which typically correspond to peak emotional experiences, can be objectively monitored by degree of pupillary dilation. Participants listened to self-chosen songs versus control songs chosen by other participants. The experiment included an active condition where participants made key presses to indicate when experiencing chills and a passive condition (without key presses). Chills were reported more frequently for self-selected songs than control songs. Pupil diameter was concurrently measured by an eye-tracker while participants listened to each of the songs. Pupil size was larger within specific time-windows around the chill events, as monitored by key responses, than in comparison to pupil size observed during 'passive' song listening. In addition, there was a clear relationship between pupil diameter within the chills-related time-windows during both active and passive conditions, thus ruling out the possibility that chills-related pupil dilations were an artifact of making a manual response. These findings strongly suggest that music chills can be visible in the moment-to-moment changes in the size of pupillary responses and that a neuromodulatory role of the central norepinephrine system is thereby implicated in this phenomenon. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  17. Comparison of performance of high-power mid-IR QCL modules in actively and passively cooled mode

    NASA Astrophysics Data System (ADS)

    Münzhuber, F.; Denzel, H.; Tholl, H. D.

    2017-10-01

    We report on the effects of active and passive cooling on the performance of high power mid-IR QCL modules (λ ≈ 3.9 μm) in quasi-cw mode. In active cooling mode, a thermo-electrical cooler attached with its hot side to a heat sink of constant temperature, a local thermometer in close proximity to the QCL chip (epi-down mounted) as well as a control unit has been used for temperature control of the QCL submount. In contrast, the passive cooling was performed by attaching the QCL module solely to the heat sink. Electro-optical light-current- (L-I-) curves are measured in a quasi-cw mode, from which efficiencies can be deduced. Waiving of the active cooling elements results in a drop of the maximum intensity of less than 5 %, compared to the case wherein the temperature of the submount is stabilized to the temperature of the heat sink. The application of a model of electro-optical performance to the data shows good agreement and captures the relevant observations. We further determine the heat resistance of the module and demonstrate that the system performance is not limited by the packaging of the module, but rather by the heat dissipation on the QCL chip itself.

  18. Application of passive sampling for measuring dissolved concentrations of organic contaminants in the water column at three marine superfund sites.

    PubMed

    Burgess, Robert M; Lohmann, Rainer; Schubauer-Berigan, Joseph P; Reitsma, Pamela; Perron, Monique M; Lefkovitz, Lisa; Cantwell, Mark G

    2015-08-01

    Currently, there is an effort under way to encourage remedial project managers at contaminated sites to use passive sampling to collect freely dissolved concentrations (Cfree ) of hydrophobic organic contaminants to improve site assessments. The objective of the present study was to evaluate the use of passive sampling for measuring water column Cfree for several hydrophobic organic contaminants at 3 US Environmental Protection Agency Superfund sites. Sites investigated included New Bedford Harbor (New Bedford, MA, USA), Palos Verdes Shelf (Los Angeles, CA, USA), and Naval Station Newport (Newport, RI, USA); and the passive samplers evaluated were polyethylene, polydimethylsiloxane-coated solid-phase microextraction fibers, semipermeable membrane devices, and polyoxymethylene. In general, the different passive samplers demonstrated good agreement, with Cfree values varying by a factor of 2 to 3. Further, at New Bedford Harbor, where conventional water sample concentrations were also measured (i.e., grab samples), passive sampler-based Cfree values agreed within a factor of 2. These findings suggest that all of the samplers were experiencing and measuring similar Cfree during their respective deployments. Also, at New Bedford Harbor, a strong log-linear, correlative, and predictive relationship was found between polyethylene passive sampler accumulation and lipid-normalized blue mussel bioaccumulation of polychlorinated biphenyls (r(2)  = 0.92, p < 0.05). The present study demonstrates the utility of passive sampling for generating scientifically accurate water column Cfree values, which is critical for making informed environmental management decisions at contaminated sediment sites. Published 2015 SETAC. This article is a US Government work and is in the public domain in the USA.

  19. Progress on FIR interferometry and Thomson Scattering measurements on HIT-SI3

    NASA Astrophysics Data System (ADS)

    Everson, Christopher; Jarboe, Thomas; Morgan, Kyle

    2017-10-01

    Spatially resolved measurements of the electron temperature (Te) and density (ne) will be fundamental in assessing the degree to which HIT-SI3 demonstrates closed magnetic flux and energy confinement. Further, electron temperature measurements have not yet been made on an inductively-driven spheromak. Far infrared (FIR) interferometer and Thomson Scattering (TS) systems have been installed on the HIT-SI3 spheromak. The TS system currently implemented on HIT-SI3 was originally designed for other magnetic confinement experiments, and progress continues toward modifying and optimizing for HIT-SI3 plasmas. Initial results suggest that the electron temperature is of order 10 eV. Plans to modify the TS system to provide more sensitivity and accuracy at low temperatures are presented. The line-integrated ne is measured on one chord by the FIR interferometer, with densities near 5x1019 m-3. Four cylindrical volumes have been added to the HIT-SI3 apparatus to enhance passive pumping. It is hoped that this will allow for more control of the density during the 2 ms discharges. Density measurements from before and after the installation of the passive pumping volumes are presented for comparison.

  20. Implementation of a six-degree-of-freedom manual controller with passive force feedback

    NASA Astrophysics Data System (ADS)

    Will, Carol C.; Crane, Carl D., III; Adsit, Phillip

    1995-12-01

    Force reflective controllers can be divided into two classes; active and passive with the most common being active. Active force-feedback controllers are prone to self-actuation which can generate unintended commands and may injure the user. A six-degree-of-freedom positional input device was designed and constructed that was capable of providing force-feedback passively through the use of six magnetic hysteresis brakes. Special hardware and control strategies were developed to account for some of the limitations of a passive system and the characteristics of hysteresis brakes. The force-feedback input device has been interfaced to a six-degree-of-freedom robot to perform a variety of tasks. Initial research was conducted with a peg-in-hole task. Future research is to include contour following and bead-on-wire tests. Initial results indicated that force-feedback may only be an improvement in situations where visual cues are not clear, and may actually be a hindrance when a clear line of sight exists.

  1. Controllable self-induced passivation of hybrid lead iodide perovskites toward high performance solar cells.

    PubMed

    Chen, Qi; Zhou, Huanping; Song, Tze-Bin; Luo, Song; Hong, Ziruo; Duan, Hsin-Sheng; Dou, Letian; Liu, Yongsheng; Yang, Yang

    2014-07-09

    To improve the performance of the polycrystalline thin film devices, it requires a delicate control of its grain structures. As one of the most promising candidates among current thin film photovoltaic techniques, the organic/inorganic hybrid perovskites generally inherit polycrystalline nature and exhibit compositional/structural dependence in regard to their optoelectronic properties. Here, we demonstrate a controllable passivation technique for perovskite films, which enables their compositional change, and allows substantial enhancement in corresponding device performance. By releasing the organic species during annealing, PbI2 phase is presented in perovskite grain boundaries and at the relevant interfaces. The consequent passivation effects and underlying mechanisms are investigated with complementary characterizations, including scanning electron microscopy (SEM), X-ray diffraction (XRD), time-resolved photoluminescence decay (TRPL), scanning Kelvin probe microscopy (SKPM), and ultraviolet photoemission spectroscopy (UPS). This controllable self-induced passivation technique represents an important step to understand the polycrystalline nature of hybrid perovskite thin films and contributes to the development of perovskite solar cells judiciously.

  2. The link between exercise and titin passive stiffness.

    PubMed

    Lalande, Sophie; Mueller, Patrick J; Chung, Charles S

    2017-09-01

    What is the topic of this review? This review focuses on how in vivo and molecular measurements of cardiac passive stiffness can predict exercise tolerance and how exercise training can reduce cardiac passive stiffness. What advances does it highlight? This review highlights advances in understanding the relationship between molecular (titin-based) and in vivo (left ventricular) passive stiffness, how passive stiffness modifies exercise tolerance, and how exercise training may be therapeutic for cardiac diseases with increased passive stiffness. Exercise can help alleviate the negative effects of cardiovascular disease and cardiovascular co-morbidities associated with sedentary behaviour; this may be especially true in diseases that are associated with increased left ventricular passive stiffness. In this review, we discuss the inverse relationship between exercise tolerance and cardiac passive stiffness. Passive stiffness is the physical property of cardiac muscle to produce a resistive force when stretched, which, in vivo, is measured using the left ventricular end diastolic pressure-volume relationship or is estimated using echocardiography. The giant elastic protein titin is the major contributor to passive stiffness at physiological muscle (sarcomere) lengths. Passive stiffness can be modified by altering titin isoform size or by post-translational modifications. In both human and animal models, increased left ventricular passive stiffness is associated with reduced exercise tolerance due to impaired diastolic filling, suggesting that increased passive stiffness predicts reduced exercise tolerance. At the same time, exercise training itself may induce both short- and long-term changes in titin-based passive stiffness, suggesting that exercise may be a treatment for diseases associated with increased passive stiffness. Direct modification of passive stiffness to improve exercise tolerance is a potential therapeutic approach. Titin passive stiffness itself may be a treatment target based on the recent discovery of RNA binding motif 20, which modifies titin isoform size and passive stiffness. Translating these discoveries that link exercise and left ventricular passive stiffness may provide new methods to enhance exercise tolerance and treat patients with cardiovascular disease. © 2017 The Authors. Experimental Physiology © 2017 The Physiological Society.

  3. Antireflection and SiO2 Surface Passivation by Liquid-Phase Chemistry for Efficient Black Silicon Solar Cells: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yuan, H. C.; Oh, J.; Zhang, Y.

    2012-06-01

    We report solar cells with both black Si antireflection and SiO2 surface passivation provided by inexpensive liquid-phase chemistry, rather than by conventional vacuum-based techniques. Preliminary cell efficiency has reached 16.4%. Nanoporous black Si antireflection on crystalline Si by aqueous etching promises low surface reflection for high photon utilization, together with lower manufacturing cost compared to vacuum-based antireflection coating. Ag-nanoparticle-assisted black Si etching and post-etching chemical treatment recently developed at NREL enables excellent control over the pore diameter and pore separation. Performance of black Si solar cells, including open-circuit voltage, short-circuit current density, and blue response, has benefited from these improvements.more » Prior to this study, our black Si solar cells were all passivated by thermal SiO2 produced in tube furnaces. Although this passivation is effective, it is not yet ideal for ultra-low-cost manufacturing. In this study, we report, for the first time, the integration of black Si with a proprietary liquid-phase deposition (LPD) passivation from Natcore Technology. The Natcore LPD forms a layer of <10-nm SiO2 on top of the black Si surface in a relatively mild chemical bath at room temperature. We demonstrate black Si solar cells with LPD SiO2 with a spectrum-weighted average reflection lower than 5%, similar to the more costly thermally grown SiO2 approach. However, LPD SiO2 provides somewhat better surface-passivation quality according to the lifetime analysis by the photo-conductivity decay measurement. Moreover, black Si solar cells with LPD SiO2 passivation exhibit higher spectral response at short wavelength compared to those passivated by thermally grown SiO2. With further optimization, the combination of aqueous black Si etching and LPD could provide a pathway for low-cost, high-efficiency crystalline Si solar cells.« less

  4. Evaluation of a passive flame-height sensor to estimate forest fire intensity.

    Treesearch

    Kevin C. Ryan

    1981-01-01

    The length of flames of wildland fires is a relative indicator of fireline intensity and an important index to fire effects and difficulty of control. A technique for measuring flame height and flame-tilt angle for the purpose of calculating flame length is described. Laboratory tests determined the feasibility of using cotton string treated with ammonium phosphate...

  5. p-Type and n-type doping of ZnSe: Effects of hydrogen incorporation

    NASA Astrophysics Data System (ADS)

    Fisher, P. A.; Ho, E.; House, J. L.; Petrich, G. S.; Kolodziejski, L. A.; Walker, J.; Johnson, N. M.

    1995-05-01

    The hydrogenation behavior of p- and n-type ZnSe grown on GaAs by gas source molecular beam epitaxy (GSMBE) is presented. Recent advances in p-type doping, using a radio frequency (RF) plasma source with nitrogen, have led to the successful fabrication of blue/green light emitters based on the (Zn,Mg)(S,Se) material system grown by molecular beam epitaxy (MBE). GSMBE replaces the high vapor pressure group VI elements with hydride gases which are amenable to regulation using precision mass flow controllers, and has the potential to deliver improved compositional control and reproducibility. We have found that the presence of hydrogen does not affect the electrical conductivity of ZnSe:Cl grown by GSMBE. In contrast, nitrogen-doped ZnSe is speculated to be electrically passivated by hydrogen for certain growth conditions as evidenced by: (1) coherent tracking of the hydrogen concentration with variations in the nitrogen concentration, which is measured by secondary ion mass spectrometry (SIMS), and (2) indications of high resistivity determined by capacitance-voltage ( C-V) measurements. Conventional and rapid thermal annealing (RTA) have been investigated to modify the degree of hydrogen passivation.

  6. Stomatal dynamics are limited by leaf hydraulics in ferns and conifers: results from simultaneous measurements of liquid and vapour fluxes in leaves.

    PubMed

    Martins, Samuel C V; McAdam, Scott A M; Deans, Ross M; DaMatta, Fábio M; Brodribb, Tim J

    2016-03-01

    Stomatal responsiveness to vapour pressure deficit (VPD) results in continuous regulation of daytime gas-exchange directly influencing leaf water status and carbon gain. Current models can reasonably predict steady-state stomatal conductance (gs ) to changes in VPD but the gs dynamics between steady-states are poorly known. Here, we used a diverse sample of conifers and ferns to show that leaf hydraulic architecture, in particular leaf capacitance, has a major role in determining the gs response time to perturbations in VPD. By using simultaneous measurements of liquid and vapour fluxes into and out of leaves, the in situ fluctuations in leaf water balance were calculated and appeared to be closely tracked by changes in gs thus supporting a passive model of stomatal control. Indeed, good agreement was found between observed and predicted gs when using a hydropassive model based on hydraulic traits. We contend that a simple passive hydraulic control of stomata in response to changes in leaf water status provides for efficient stomatal responses to VPD in ferns and conifers, leading to closure rates as fast or faster than those seen in most angiosperms. © 2015 John Wiley & Sons Ltd.

  7. Measurement of indoor formaldehyde concentrations with a passive sampler

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gillett, R.W.; Kreibich, H.; Ayers, G.P.

    2000-05-15

    An existing Ferm-type passive sampler technique has been further developed to measure concentrations of formaldehyde gas in indoor air. Formaldehyde forms a derivative after reaction with a filter coated with 2,4-dinitrophenylhydrazine (2,4-DNPH). The formaldehyde 2,4-dinitrophenylhydrazine derivative (formaldehyde-2,4-DNPH) is extracted from the filter, and the concentration is determined by high-performance liquid chromatography. The technique has been validated against an active sampling method, and the agreement is close when the appropriate laminar boundary layer depth is applied to the passive measurement. For this technique an exposure period of 3 days is equivalent to a limit of detection of formaldehyde of 3.4 ppbvmore » and a limit of quantification of 7.6 ppbv. To test the performance of the passive samplers ambient formaldehyde measurements were carried out inside homes and in a range of workplace environments.« less

  8. The application of active side arm controllers in helicopters

    NASA Technical Reports Server (NTRS)

    Knorr, R.; Melz, C.; Faulkner, A.; Obermayer, M.

    1993-01-01

    Eurocopter Deutschland (ECD) started simulation trials to investigate the particular problems of Side Arm Controllers (SAC) applied to helicopters. Two simulation trials have been performed. In the first trial, the handling characteristics of a 'passive' SAC and the basic requirements for the application of an 'active' SAC were evaluated in pilot-in-the-loop simulations, performing the tasks in a realistic scenario representing typical phases of a transport mission. The second simulation trial investigated the general control characteristics of the 'active' in comparison to the 'passive' control principle. A description of the SACs developed by ECD and the principle of the 'passive' and 'active' control concept is given, as well as specific ratings for the investigated dynamic and ergonomic parameters effecting SAC characteristics. The experimental arrangements, as well as the trials procedures of both simulation phases, are described and the results achieved are discussed emphasizing the advantages of the 'active' as opposed to the 'passive' SAC concept. This also includes the presentation of some critical aspects still to be improved and proposals to solve them.

  9. Active prospective control is required for effective sensorimotor learning.

    PubMed

    Snapp-Childs, Winona; Casserly, Elizabeth; Mon-Williams, Mark; Bingham, Geoffrey P

    2013-01-01

    Passive modeling of movements is often used in movement therapy to overcome disabilities caused by stroke or other disorders (e.g. Developmental Coordination Disorder or Cerebral Palsy). Either a therapist or, recently, a specially designed robot moves or guides the limb passively through the movement to be trained. In contrast, action theory has long suggested that effective skill acquisition requires movements to be actively generated. Is this true? In view of the former, we explicitly tested the latter. Previously, a method was developed that allows children with Developmental Coordination Disorder to produce effective movements actively, so as to improve manual performance to match that of typically developing children. In the current study, we tested practice using such active movements as compared to practice using passive movement. The passive movement employed, namely haptic tracking, provided a strong test of the comparison, one that showed that the mere inaction of the muscles is not the problem. Instead, lack of prospective control was. The result was no effective learning with passive movement while active practice with prospective control yielded significant improvements in performance.

  10. Plant Chlorophyll fluorescence: active and passive measurements at canopy and leaf scales with different nitrogen treatments

    USDA-ARS?s Scientific Manuscript database

    Most studies assessing chlorophyll fluorescence (ChlF) have examined leaf responses to environmental stress conditions using active techniques. Alternatively, passive techniques are able to measure ChlF at both leaf and canopy scales. However, although the measurement principles of both techniques a...

  11. Using passive capillary lysimeter water flux measurements to improve flow predictions in variably saturated soils.

    USDA-ARS?s Scientific Manuscript database

    Passive capillary lysimeters (PCLs) are uniquely suited for measuring water fluxes in variably-saturated soils. The objective of this work was to compare PCL flux measurements with simulated fluxes obtained with a calibrated unsaturated flow model. The Richards equation-based model was calibrated us...

  12. Evaluating the Relationship between Equilibrium Passive ...

    EPA Pesticide Factsheets

    This review evaluates passive sampler uptake of hydrophobic organic contaminants (HOCs) in water column and interstitial water exposures as a surrogate for organism bioaccumulation. Fifty-four studies were found where both passive sampler uptake and organism bioaccumulation were measured and 19 of these investigations provided direct comparisons relating passive sampler uptake and organism bioaccumulation. Polymers compared included low density polyethylene (LDPE), polyoxymethylene (POM), and polydimethylsiloxane (PDMS), and organisms ranged from polychaetes and oligochaetes to bivalves, aquatic insects, and gastropods. Regression equations correlating bioaccumulation (CL) and passive sampler uptake (CPS) were used to assess the strength of observed relationships. Passive sampling based concentrations resulted in logarithmic predictive relationships, most of which were within one to two orders of magnitude of measured bioaccumulation. Mean coefficients of determination (r2) for LDPE, PDMS and POM were 0.68, 0.76 and 0.58, respectively. For the available raw data, the mean ratio of CL and CPS was 10.8 ± 18.4 (n = 609). This review concludes that in many applications passive sampling may serve as a reliable surrogate for biomonitoring organisms when biomonitoring organisms are not available. When applied properly, passive sampling based estimates of bioaccumulation provide useful information for making informed decisions about the bioavailability of HOCs

  13. Engineering Photonic Devices and Materials Through Quantum Confinement and Electromagnetic Design

    DTIC Science & Technology

    2010-12-20

    selectivity based on the Al concentration in AlGaAs films [27]. Preliminary calibration has demonstrated that a 4:1 ratio of citric acid to hydrogen...positioning the mode near 800 nm. We first simulated the reflectance of the proposed device in a passive FDTD simulation by introducing a Gaussian pulse... passively , enabling us to measure much higher quality factors than was possible using our spectrometer. The passive measurements were conducted by

  14. Application of Shark Skin Flow Control Techniques to Airflow

    NASA Astrophysics Data System (ADS)

    Morris, Jackson Alexander

    Due to millions of years of evolution, sharks have evolved to become quick and efficient ocean apex predators. Shark skin is made up of millions of microscopic scales, or denticles, that are approximately 0.2 mm in size. Scales located on the shark's body where separation control is paramount (such as behind the gills or the trailing edge of the pectoral fin) are capable of bristling. These scales are hypothesized to act as a flow control mechanism capable of being passively actuated by reversed flow. It is believed that shark scales are strategically sized to interact with the lower 5% of a boundary layer, where reversed flow occurs at the onset of boundary layer separation. Previous research has shown shark skin to be capable of controlling separation in water. This thesis aims to investigate the same passive flow control techniques in air. To investigate this phenomenon, several sets of microflaps were designed and manufactured with a 3D printer. The microflaps were designed in both 2D (rectangular) and 3D (mirroring shark scale geometry) variants. These microflaps were placed in a low-speed wind tunnel in the lower 5% of the boundary layer. Solid fences and a flat plate diffuser with suction were placed in the tunnel to create different separated flow regions. A hot film probe was used to measure velocity magnitude in the streamwise plane of the separated regions. The results showed that low-speed airflow is capable of bristling objects in the boundary layer. When placed in a region of reverse flow, the microflaps were passively actuated. Microflaps fluctuated between bristled and flat states in reverse flow regions located close to the reattachment zone.

  15. High LET, passive space radiation dosimetry and spectrometry

    NASA Technical Reports Server (NTRS)

    Benton, E. V.; Frank, A. L.; Benton, E. R.; Keegan, R. P.; Frigo, L. A.; Sanner, D.; Rowe, V.

    1995-01-01

    The development of high linear energy transfer (LET), passive radiation dosimetry and spectrometry is needed for the purpose of accurate determination of equivalent doses and assessment of health risks to astronauts on long duration missions. Progress in the following research areas is summerized: intercomparisons of cosmic ray equivalent dose and LET spectra measurements between STS missions and between astronauts; increases LET spectra measurement accuracy with ATAS; space radiation measurements for intercomparisons of passive (PNTD, TLD, TRND, Emulsion) and active (TEPC, RME-111) dosimeters; interaction of cosmic ray particles with nuclei in matter; radiation measurements after long duration space exposures; ground based dosimeter calibrations; neutron detector calibrations; radiation measurements on Soviet/Russian spacecraft; space radiation measurements under thin shielding; and space radiation.

  16. Laser angle measurement system

    NASA Technical Reports Server (NTRS)

    Pond, C. R.; Texeira, P. D.; Wilbert, R. E.

    1980-01-01

    The design and fabrication of a laser angle measurement system is described. The instrument is a fringe counting interferometer that monitors the pitch attitude of a model in a wind tunnel. A laser source and detector are mounted above the mode. Interference fringes are generated by a small passive element on the model. The fringe count is accumulated and displayed by a processor in the wind tunnel control room. Optical and electrical schematics, system maintenance and operation procedures are included, and the results of a demonstration test are given.

  17. Hybrid Damping System for an Electronic Equipment Mounting Shelf

    NASA Technical Reports Server (NTRS)

    Voracek, David; Kolkailah, Faysal A.; Cavalli, J. R.; Elghandour, Eltahry

    1997-01-01

    The objective of this study was to design and construct a vibration control system for an electronic equipment shelf to be evaluated in the NASA Dryden FTF-II. The vibration control system was a hybrid system which included passive and active damping techniques. Passive damping was fabricated into the equipment shelf using ScothDamp(trademark) damping film and aluminum constraining layers. Active damping was achieved using a two channel active control circuit employing QuickPack(trademark) sensors and actuators. Preliminary Chirp test results indicated passive damping smoothed the frequency response while active damping reduced amplitudes of the frequency response for most frequencies below 500Hz.

  18. Hybrid Damping System for an Electronic Equipment Mounting Shelf

    NASA Technical Reports Server (NTRS)

    Voracek, David; Kolkailah, Faysal A.; Cavalli, J. R.; Elghandour, Eltahry

    1997-01-01

    The objective of this study was to design and construct a vibration control system for an electronic equipment shelf to be evaluated in the NASA Dryden FTF-11. The vibration control system was a hybrid system which included passive and active damping techniques. Passive damping was fabricated into the equipment shelf using ScothDamp(trademark) damping film and aluminum constraining layers. Active damping was achieved using a two channel active control circuit employing QuickPack(trademark) sensors and actuators. Preliminary Chirp test results indicated passive damping smoothed the frequency response while active damping reduced amplitudes of the frequency response for most frequencies below 500Hz.

  19. Passive and active floating torque during swimming.

    PubMed

    Kjendlie, Per-Ludvik; Stallman, Robert Keig; Stray-Gundersen, James

    2004-10-01

    The purpose of this study was to examine the effect of passive underwater torque on active body angle with the horizontal during front crawl swimming and to assess the effect of body size on passive torque and active body angle. Additionally, the effects of passive torque, body angle and hydrostatic lift on maximal sprinting performance were addressed. Ten boys [aged 11.7 (0.8) years] and 12 male adult [aged 21.4 (3.7) years] swimmers volunteered to participate. Their body angle with the horizontal was measured at maximal velocity, and at two submaximal velocities using an underwater video camera system. Passive torque and hydrostatic lift were measured during an underwater weighing procedure, and the center of mass and center of volume were determined. The results showed that passive torque correlated significantly with the body angle at a velocity 63% of v(max) ( alpha(63) r=-0.57), and that size-normalized passive torque correlated significantly with the alpha(63) and alpha(77) (77% of v(max)) with r=-0.59 and r=-0.54 respectively. Hydrostatic lift correlated with alpha(63) with r=-0.45. The negative correlation coefficients are suggested to be due to the adults having learned to overcome passive torque when swimming at submaximal velocities by correcting their body angle. It is concluded that at higher velocities the passive torque and hydrostatic lift do not influence body angle during swimming. At a velocity of 63% of v(max), hydrostatic lift and passive torque influences body angle. Passive torque and size-normalized passive torque increases with body size. When corrected for body size, hydrostatic lift and passive torque did not influence the maximal sprinting velocity.

  20. Design of a vibration isolation system for a cycle ergometer to be used onboard the Space Shuttle

    NASA Technical Reports Server (NTRS)

    Pearson, Lillian; Tait, Steven; Trevino, Maurice

    1991-01-01

    Low frequency vibrations generated during exercise using the cycle ergometer onboard the Space Shuttle are disrupting sensitive microgravity experiments. The design team is asked by NASA/USRA to generate alternatives for the design of a vibration isolation system for the cycle ergometer. It is the design team's objective to present alternative designs and a problem solution for a vibration isolation system for an exercise cycle ergometer to be used onboard the Space Shuttle. In the development of alternative designs, the design team emphasizes passive systems as opposed to active control systems. This decision is made because the team feels that passive systems are less complex than active control systems, external energy sources are not required, and mass is reduced due to the lack of machinery such as servomotors or compressors typical of active control systems. Eleven alternative designs are developed by the design team. From these alternatives, three active control systems are included to compare the benefits of active and passive systems. Also included in the alternatives is an isolation system designed by an independent engineer that was acquired late in the project. The eight alternatives using passive isolation systems are narrowed down by selection criteria to four considered to be the most promising by the design team. A feasibility analysis is performed on these four passive isolation systems. Based on the feasibility analysis, a final design solution is chosen and further developed. From the development of the design, the design team has concluded that passive systems are not effective at isolating vibrations for the low frequencies considered for this project. Recommendations are made for guidelines of passive isolation design and application of such systems.

  1. A Closed-Loop Optimal Neural-Network Controller to Optimize Rotorcraft Aeromechanical Behaviour. Volume 1; Theory and Methodology

    NASA Technical Reports Server (NTRS)

    Leyland, Jane Anne

    2001-01-01

    Given the predicted growth in air transportation, the potential exists for significant market niches for rotary wing subsonic vehicles. Technological advances which optimise rotorcraft aeromechanical behaviour can contribute significantly to both their commercial and military development, acceptance, and sales. Examples of the optimisation of rotorcraft aeromechanical behaviour which are of interest include the minimisation of vibration and/or loads. The reduction of rotorcraft vibration and loads is an important means to extend the useful life of the vehicle and to improve its ride quality. Although vibration reduction can be accomplished by using passive dampers and/or tuned masses, active closed-loop control has the potential to reduce vibration and loads throughout a.wider flight regime whilst requiring less additional weight to the aircraft man that obtained by using passive methads. It is ernphasised that the analysis described herein is applicable to all those rotorcraft aeromechanical behaviour optimisation problems for which the relationship between the harmonic control vector and the measurement vector can be adequately described by a neural-network model.

  2. Passive and semi-active heave compensator: Project design methodology and control strategies.

    PubMed

    Cuellar Sanchez, William Humberto; Linhares, Tássio Melo; Neto, André Benine; Fortaleza, Eugênio Libório Feitosa

    2017-01-01

    Heave compensator is a system that mitigates transmission of heave movement from vessels to the equipment in the vessel. In drilling industry, a heave compensator enables drilling in offshore environments. Heave compensator attenuates movement transmitted from the vessel to the drill string and drill bit ensuring security and efficiency of the offshore drilling process. Common types of heave compensators are passive, active and semi-active compensators. This article presents 4 main points. First, a bulk modulus analysis obtains a simple condition to determine if the bulk modulus can be neglected in the design of hydropneumatic passive heave compensator. Second, the methodology to design passive heave compensators with the desired frequency response. Third, four control methodologies for semi-active heave compensator are tested and compared numerically. Lastly, we show experimental results obtained from a prototype with the methodology developed to design passive heave compensator.

  3. A Cr4+:YAG passively Q-switched Nd:YVO4 microchip laser for controllable high-order Hermite-Gaussian modes

    NASA Astrophysics Data System (ADS)

    Dong, Jun; He, Yu; Bai, Sheng-Chuang; Ueda, Ken-ichi; Kaminskii, Alexander A.

    2016-09-01

    A nanosecond, high peak power, passively Q-switched laser for controllable Hermite-Gaussian (HG) modes has been achieved by manipulating the saturated inversion population inside the gain medium. The stable HG modes are generated in a Cr4+:YAG passively Q-switched Nd:YVO4 microchip laser by applying a tilted pump beam. The asymmetrical saturated inversion population distribution inside the Nd:YVO4 crystal for desirable HG modes is manipulated by choosing the proper pump beam diameter and varying pump power. A HG9,8 mode passively Q-switched Nd:YVO4 microchip laser with average output power of 265 mW has been obtained. Laser pulses with a pulse width of 7.3 ns and peak power of over 1.7 kW working at 21 kHz have been generated in the passively Q-switched Nd:YVO4 microchip laser.

  4. Passive and semi-active heave compensator: Project design methodology and control strategies

    PubMed Central

    Cuellar Sanchez, William Humberto; Neto, André Benine; Fortaleza, Eugênio Libório Feitosa

    2017-01-01

    Heave compensator is a system that mitigates transmission of heave movement from vessels to the equipment in the vessel. In drilling industry, a heave compensator enables drilling in offshore environments. Heave compensator attenuates movement transmitted from the vessel to the drill string and drill bit ensuring security and efficiency of the offshore drilling process. Common types of heave compensators are passive, active and semi-active compensators. This article presents 4 main points. First, a bulk modulus analysis obtains a simple condition to determine if the bulk modulus can be neglected in the design of hydropneumatic passive heave compensator. Second, the methodology to design passive heave compensators with the desired frequency response. Third, four control methodologies for semi-active heave compensator are tested and compared numerically. Lastly, we show experimental results obtained from a prototype with the methodology developed to design passive heave compensator. PMID:28813494

  5. Independent and joint exposure to passive smoking and cooking oil fumes on oral cancer in Chinese women: a hospital-based case-control study.

    PubMed

    He, Baochang; Chen, Fa; Yan, Lingjun; Huang, Jiangfeng; Liu, Fangping; Qiu, Yu; Lin, Lisong; Zhang, Zuofeng; Cai, Lin

    2016-10-01

    Passive smoking and COF exposure are independent risk factors for oral cancer in Chinese women, with the multiplicative interactions from combined exposures. Avoiding exposure to environmental tobacco smoke and COF may contribute to the prevention of oral cancer in Chinese women. To evaluate the independent and joint effects of passive smoking and cooking oil fumes (COF) on oral cancer in Chinese women. A case-control study was performed including 238 female patients with pathologically confirmed oral cancer and 470 controls as age-matched controls. Face-to-face interviews were conducted based on a structured questionnaire. The effects of passive smoking and COF exposure were analyzed using non-conditional logistic regression models. Passive smoking significantly increased the risk of oral cancer in Chinese women: adjusted ORs were 2.12 (95% CI = 1.11-4.07) for those only exposed before age 18, 1.52 (95% CI = 1.01-2.31) for those only exposed after age 18, and 2.38 (95% CI = 1.47-3.85) for those both exposed before and after age 18. In addition, COF exposure was significantly associated with a risk of oral cancer (adjusted ORs were 1.69 (95% CI = 1.03-2.78) for light exposure and 2.06 (95% CI = 1.21-3.50) for heavy exposure). Furthermore, there was a significantly multiplicative interaction between passive smoking and COF for oral cancer.

  6. Addition of Passive Dynamics to a Flapping Airfoil to Improve Performance

    NASA Astrophysics Data System (ADS)

    Asselin, Daniel; Young, Jay; Williamson, C. H. K.

    2017-11-01

    Animals which fly or swim typically employ flapping motions of their wings and fins in order to produce thrust and to maneuver. Small, unmanned vehicles might also exploit such motions and are of considerable interest for the purposes of surveillance, environmental monitoring, and search and rescue. Flapping refers to a combination of pitch and heave and has been shown to provide good thrust and efficiency (Read, et al. 2003) when both axes are independently controlled (an Active-Active system). In this study, we examine the performance of an airfoil actuated only in the heave direction but allowed to pitch passively under the control of a torsion spring (an Active-Passive system). The presence of the spring is simulated in software using a force-feedback control system called Cyber-Physical Fluid Dynamics, or CPFD (Mackowski & Williamson 2011, 2015, 2016). Adding passive pitch to active heave provides significantly improved thrust and efficiency compared with heaving alone, especially when the torsion spring stiffness is selected so that the system operates near resonance (in an Active-Passive system). In many cases, values of thrust and efficiency are comparable to or better than those obtained with two actively controlled degrees of freedom. By using carefully-designed passive dynamics in the pitch direction, we can eliminate one of the two actuators, saving cost, complexity, and weight, while maintaining performance. This work was supported by the Air Force Office of Scientific Research Grant No. FA9550-15-1-0243, monitored by Dr. Douglas Smith.

  7. Ammonia Generation and Utilization in a Passive SCR (TWC+SCR) System on Lean Gasoline Engine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prikhodko, Vitaly Y.; James E. Parks, II; Pihl, Josh A.

    Lean gasoline engines offer greater fuel economy than the common stoichiometric gasoline engine, but the current three way catalyst (TWC) on stoichiometric engines is unable to control nitrogen oxide (NOX) emissions in oxidizing exhaust. For these lean gasoline engines, lean NOX emission control is required to meet existing Tier 2 and upcoming Tier 3 emission regulations set by the U.S. Environmental Protection Agency (EPA). While urea-based selective catalytic reduction (SCR) has proven effective in controlling NOX from diesel engines, the urea storage and delivery components can add significant size and cost. As such, onboard NH 3 production via a passivemore » SCR approach is of interest. In a passive SCR system, NH 3 is generated over a close-coupled TWC during periodic slightly rich engine operation and subsequently stored on an underfloor SCR catalyst. Upon switching to lean operation, NOX passes through the TWC and is reduced by the stored NH 3 on the SCR catalyst. In this work, a passive SCR system was evaluated on a 2.0-liter BMW lean burn gasoline direct injection engine to assess NH 3 generation over a Pd-only TWC and utilization over a Cu-based SCR catalyst. System NOX reduction efficiency and fuel efficiency improvement compared to stoichiometric engine operation were measured. A feedback control strategy based on cumulative NH 3 produced by the TWC during rich operation and NOX emissions during lean operation was implemented on the engine to control lean/rich cycle timing. At an SCR average inlet temperature of 350 °C, an NH 3:NOX ratio of 1.15:1 (achieved through longer rich cycle timing) resulted in 99.7 % NOX conversion. Increasing NH 3 generation further resulted in even higher NOX conversion; however, tailpipe NH 3 emissions resulted. At higher underfloor temperatures, NH 3 oxidation over the SCR limited NH 3 availability for NOX reduction. At the engine conditions studied, greater than 99 % NOX conversion was achieved with passive SCR while delivering fuel efficiency benefits ranging between 6-11 % compared with stoichiometric operation.« less

  8. Ammonia Generation and Utilization in a Passive SCR (TWC+SCR) System on Lean Gasoline Engine

    DOE PAGES

    Prikhodko, Vitaly Y.; James E. Parks, II; Pihl, Josh A.; ...

    2016-04-05

    Lean gasoline engines offer greater fuel economy than the common stoichiometric gasoline engine, but the current three way catalyst (TWC) on stoichiometric engines is unable to control nitrogen oxide (NOX) emissions in oxidizing exhaust. For these lean gasoline engines, lean NOX emission control is required to meet existing Tier 2 and upcoming Tier 3 emission regulations set by the U.S. Environmental Protection Agency (EPA). While urea-based selective catalytic reduction (SCR) has proven effective in controlling NOX from diesel engines, the urea storage and delivery components can add significant size and cost. As such, onboard NH 3 production via a passivemore » SCR approach is of interest. In a passive SCR system, NH 3 is generated over a close-coupled TWC during periodic slightly rich engine operation and subsequently stored on an underfloor SCR catalyst. Upon switching to lean operation, NOX passes through the TWC and is reduced by the stored NH 3 on the SCR catalyst. In this work, a passive SCR system was evaluated on a 2.0-liter BMW lean burn gasoline direct injection engine to assess NH 3 generation over a Pd-only TWC and utilization over a Cu-based SCR catalyst. System NOX reduction efficiency and fuel efficiency improvement compared to stoichiometric engine operation were measured. A feedback control strategy based on cumulative NH 3 produced by the TWC during rich operation and NOX emissions during lean operation was implemented on the engine to control lean/rich cycle timing. At an SCR average inlet temperature of 350 °C, an NH 3:NOX ratio of 1.15:1 (achieved through longer rich cycle timing) resulted in 99.7 % NOX conversion. Increasing NH 3 generation further resulted in even higher NOX conversion; however, tailpipe NH 3 emissions resulted. At higher underfloor temperatures, NH 3 oxidation over the SCR limited NH 3 availability for NOX reduction. At the engine conditions studied, greater than 99 % NOX conversion was achieved with passive SCR while delivering fuel efficiency benefits ranging between 6-11 % compared with stoichiometric operation.« less

  9. THE PASSIVE PROPERTIES OF MUSCLE FIBERS ARE VELOCITY DEPENDENT

    PubMed Central

    Rehorn, Michael R.; Schroer, Alison K.; Blemker, Silvia S.

    2014-01-01

    The passive properties of skeletal muscle play an important role in muscle function. While the passive quasi-static elastic properties of muscle fibers have been well characterized, the dynamic visco-elastic passive behavior of fibers has garnered less attention. In particular, it is unclear how the visco-elastic properties are influenced by lengthening velocity, in particular for the range of physiologically relevant velocities. The goals of this work were to: (i) measure the effects of lengthening velocity on the peak stresses within single muscle fibers to determine how passive behavior changes over a range of physiologically relevant lengthening rates (0.1–10 Lo/s), and (ii) develop a mathematical model of fiber viscoelasticity based on these measurements. We found that passive properties depend on strain rate, in particular at the low loading rates (0.1–3 Lo/s), and that the measured behavior can be predicted across a range of loading rates and time histories with a quasi-linear viscoelastic model. In the future, these results can be used to determine the impact of viscoelastic behavior on intramuscular stresses and forces during a variety of dynamic movements. PMID:24360198

  10. Active-passive vibration absorber of beam-cart-seesaw system with piezoelectric transducers

    NASA Astrophysics Data System (ADS)

    Lin, J.; Huang, C. J.; Chang, Julian; Wang, S.-W.

    2010-09-01

    In contrast with fully controllable systems, a super articulated mechanical system (SAMS) is a controlled underactuated mechanical system in which the dimensions of the configuration space exceed the dimensions of the control input space. The objectives of the research are to develop a novel SAMS model which is called beam-cart-seesaw system, and renovate a novel approach for achieving a high performance active-passive piezoelectric vibration absorber for such system. The system consists of two mobile carts, which are coupled via rack and pinion mechanics to two parallel tracks mounted on pneumatic rodless cylinders. One cart carries an elastic beam, and the other cart acts as a counterbalance. One adjustable counterweight mass is also installed underneath the seesaw to serve as a passive damping mechanism to absorb impact and shock energy. The motion and control of a Bernoulli-Euler beam subjected to the modified cart/seesaw system are analyzed first. Moreover, gray relational grade is utilized to investigate the sensitivity of tuning the active proportional-integral-derivative (PID) controller to achieve desired vibration suppression performance. Consequently, it is shown that the active-passive vibration absorber can not only provide passive damping, but can also enhance the active action authority. The proposed software/hardware platform can also be profitable for the standardization of laboratory equipment, as well as for the development of entertainment tools.

  11. CAN CONTINGENT VALUATION MEASURE PASSIVE USE VALUES

    EPA Science Inventory

    Contingent valuation (CV) is the only method currently available for practically measuring passive-use values. Because proposed laws may require that environmental regulations pass a benefit-cost test, CV has become central to the policy debate on environmental protection. Crit...

  12. Mars 1064-nm Spectral Radiance Measurements from the Receiver Noise Response of the Mars Orbiter Laser Altimeter

    NASA Technical Reports Server (NTRS)

    Sun, Xiaoli; Neumann, Gregory A.; Abshire, James B.; Zuber, Maria T.

    2005-01-01

    The Mars Orbiter Laser Altimeter not only provides surface topography from the laser pulse time-of-flight, but also two radiometric measurements, the active measurement of transmitted and reflected laser pulse energy, and the passive measurement of reflected solar illumination. The passive radiometry measurement is accomplished in a novel fashion by monitoring the noise density at the output of the photodetector and solving for the amount of background light. The passive radiometry measurements provide images of Mars at 1064-nm wavelength over a 2 nm bandwidth with sub-km spatial resolution and with 2% or better precision under full illumination. We describe in this paper the principle of operation, the receiver mathematical model, its calibration, and performance assessment from sample measurement data.

  13. Associations between antioxidant vitamins and the risk of invasive cervical cancer in Chinese women: A case-control study

    PubMed Central

    Guo, Liyuan; Zhu, Hong; Lin, Chengjun; Che, Jianhua; Tian, Xiujuan; Han, Shiyu; Zhao, Honghui; Zhu, Yumei; Mao, Dongwei

    2015-01-01

    Previous studies on the associations between dietary antioxidant vitamins and the risk of cervical cancer remain inconsistent, and little evidence is available for serum antioxidant vitamins, which provide more accurate measurements of these nutrients. We conducted a case-control study of 458 incident cases with invasive cervical cancer and 742 controls to assess the effects of diet or serum antioxidant vitamins. Higher serum antioxidant vitamins were associated with a lower risk of cervical cancer after adjusting for potential confounders. The odds ratios (ORs) for the highest (vs. lowest) quartile were 0.66 (95% confidence interval [CI] = 0.46–0.93; P = 0.024) for α-carotene, 0.63 (95% CI = 0.45–0.90; P = 0.006) for β-carotene, 0.53 (95% CI = 0.37–0.74; P < 0.001) for vitamin E, and 0.48 (95% CI = 0.33–0.69; P < 0.001) for vitamin C. Dietary intakes of vitamins E and C were inversely associated with the risk of cervical cancer. Risk of cervical cancer from serum antioxidant vitamins was more evident in passive smokers than non-passive smokers. These findings indicated that antioxidant vitamins (mainly α-carotene, β-carotene, and vitamins E and C) might be beneficial in reducing the risk of invasive cervical cancer in Chinese women, especially in passive smokers. PMID:26337940

  14. Control issues of microgravity vibration isolation

    NASA Technical Reports Server (NTRS)

    Knospe, Carl R.; Hampton, Richard D.

    1991-01-01

    Active vibration isolation systems contemplated for microgravity space experiments may be designed to reach given performance requirements in a variety of ways. An analogy to passive isolation systems proves to be illustrative but lacks the flexibility as a design tool of a control systems approach and may lead to poor design. Control theory as applied to vibration isolation is reviewed and passive analogies discussed.

  15. ERP correlates of object recognition memory in Down syndrome: Do active and passive tasks measure the same thing?

    PubMed

    Van Hoogmoed, A H; Nadel, L; Spanò, G; Edgin, J O

    2016-02-01

    Event related potentials (ERPs) can help to determine the cognitive and neural processes underlying memory functions and are often used to study populations with severe memory impairment. In healthy adults, memory is typically assessed with active tasks, while in patient studies passive memory paradigms are generally used. In this study we examined whether active and passive continuous object recognition tasks measure the same underlying memory process in typically developing (TD) adults and in individuals with Down syndrome (DS), a population with known hippocampal impairment. We further explored how ERPs in these tasks relate to behavioral measures of memory. Data-driven analysis techniques revealed large differences in old-new effects in the active versus passive task in TD adults, but no difference between these tasks in DS. The group with DS required additional processing in the active task in comparison to the TD group in two ways. First, the old-new effect started 150 ms later. Second, more repetitions were required to show the old-new effect. In the group with DS, performance on a behavioral measure of object-location memory was related to ERP measures across both tasks. In total, our results suggest that active and passive ERP memory measures do not differ in DS and likely reflect the use of implicit memory, but not explicit processing, on both tasks. Our findings highlight the need for a greater understanding of the comparison between active and passive ERP paradigms before they are inferred to measure similar functions across populations (e.g., infants or intellectual disability). Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Passive immunization with Pneumovax® 23 and pneumolysin in combination with vancomycin for pneumococcal endophthalmitis.

    PubMed

    Sanders, Melissa E; Taylor, Sidney; Tullos, Nathan; Norcross, Erin W; Moore, Quincy C; Thompson, Hilary; King, Lauren B; Marquart, Mary E

    2013-03-11

    Capsule and pneumolysin (PLY) are two major virulence factors of Streptococcus pneumoniae. S. pneumoniae is one of the leading causes of bacterial endophthalmitis. The aim of this study is to determine whether passive immunization with the 23-valent pneumococcal polysaccharide vaccine (Pneumovax® 23; PPSV23) or PLY protects against pneumococcal endophthalmitis. New Zealand white rabbits were passively immunized with antiserum to PLY, PPSV23, a mixture of PPSV23/PLY, or PBS (mock). Vitreous was infected with a clinical strain of S. pneumoniae. In a separate group of experiments, vancomycin was injected 4 hours post-infection (PI) for each passively immunized group. Severity of infection, bacterial recovery, myeloperoxidase (MPO) activity and percent loss of retinal function were determined. Passive immunization with each antiserum significantly lowered clinical severity compared to mock immunization (PPSV23 = 9.19, PPSV23/PLY = 10.45, PLY = 8.71, Mock = 16.83; P = 0.0467). A significantly higher bacterial load was recovered from the vitreous of PLY passively immunized rabbits 24 hours PI (7.87 log10 CFU) compared to controls (7.10 log10 CFU; P = 0.0134). Retinas from immunized rabbits were more intact. Vitreous of PLY (2.88 MPO untis/mL) and PPSV23/PLY (2.17) passively immunized rabbits had less MPO activity compared to controls (5.64; P = 0.0480), and both passive immunizations (PLY = 31.34% loss of retinal function, PPSV23/PLY = 27.44%) helped to significantly preserve retinal function compared to controls (64.58%; P = 0.0323). When vancomycin was administered 4 hours PI, all eyes were sterile at 24 hours PI. A significantly lower clinical severity was observed for rabbits administered the combination immunization (5.29) or PPSV23 (5.29) with vancomycin treatment compared to controls (17.68; P = 0.0469). Passive immunization with antisera to these antigens is effective in reducing clinical severity of pneumococcal endophthalmitis in rabbits. Addition of vancomycin to immunization is effective at eliminating the bacteria.

  17. Determining Passive Sampler Partition Coefficients for Dissolved-phase Organic Contaminants

    EPA Science Inventory

    Passive samplers are used for environmental and analytical purposes to measure dissolved nonionic organic contaminants (NOCs) by absorption from a contaminated medium into a clean phase, usually in the form of a synthetic organic film. Recently developed passive sampler techniqu...

  18. Water hammer caused by closure of turbine safety spherical valves

    NASA Astrophysics Data System (ADS)

    Karadžić, U.; Bergant, A.; Vukoslavčević, P.

    2010-08-01

    This paper investigates water hammer effects caused by closure of spherical valves against the discharge. During the first phase of modernisation of Perućica high-head hydropower plant (HPP), Montenegro, safety spherical valves (inlet turbine valves) have been refurbished on the first two Pelton turbine units. The valve closure is controlled by the valve actuator (hydraulic servomotor). Because the torque acting on the valve body is dependent on flow conditions the valve closing time may vary significantly for different flow velocities (passive valve). For the passive valve the torques acting on the valve body should be considered in the valve model. The valve closing time results from numerical simulation. On the contrary, for the active valve the valve closing time is assumed prior to simulation. The spherical valve boundary condition is incorporated into the method of characteristics (MOC) algorithm. The staggered (diamond) grid in applying the MOC is used in this paper. The passive valve boundary condition is described by the water hammer equations, the valve equation that relates discharge to pressure head drop and the dynamic equation of the valve body motion (torque equation). The active valve boundary condition is described by the first two equations, respectively. Standard quasi-steady friction model is used for estimating friction losses in plant's tunnel and penstocks. Numerical results using both the active and the passive spherical valve models are compared with results of measurements. It has been found that the influence of flow conditions on the spherical valve closing time is minor for the cases considered. Computed and measured results agree reasonably well.

  19. Study of thickness and uniformity of oxide passivation with DI-O3 on silicon substrate for electronic and photonic applications

    NASA Astrophysics Data System (ADS)

    Sharma, Mamta; Hazra, Purnima; Singh, Satyendra Kumar

    2018-05-01

    Since the beginning of semiconductor fabrication technology evolution, clean and passivated substrate surface is one of the prime requirements for fabrication of Electronic and optoelectronic device fabrication. However, as the scale of silicon circuits and device architectures are continuously decreased from micrometer to nanometer (from VLSI to ULSI technology), the cleaning methods to achieve better wafer surface qualities has raised research interests. The development of controlled and uniform silicon dioxide is the most effective and reliable way to achieve better wafer surface quality for fabrication of electronic devices. On the other hand, in order to meet the requirement of high environment safety/regulatory standards, the innovation of cleaning technology is also in demand. The controlled silicon dioxide layer formed by oxidant de-ionized ozonated water has better uniformity. As the uniformity of the controlled silicon dioxide layer is improved on the substrate, it enhances the performance of the devices. We can increase the thickness of oxide layer, by increasing the ozone time treatment. We reported first time to measurement of thickness of controlled silicon dioxide layer and obtained the uniform layer for same ozone time.

  20. Water equivalent hydrogen estimates from the first 200 sols of Curiosity's traverse (Bradbury Landing to Yellowknife Bay): Results from the Dynamic Albedo of Neutrons (DAN) passive mode experiment

    NASA Astrophysics Data System (ADS)

    Tate, C. G.; Moersch, J.; Jun, I.; Ming, D. W.; Mitrofanov, I.; Litvak, M.; Behar, A.; Boynton, W. V.; Deflores, L.; Drake, D.; Ehresmann, B.; Fedosov, F.; Golovin, D.; Hardgrove, C.; Harshman, K.; Hassler, D. M.; Kozyrev, A. S.; Kuzmin, R.; Lisov, D.; Malakhov, A.; Milliken, R.; Mischna, M.; Mokrousov, M.; Nikiforov, S.; Sanin, A. B.; Starr, R.; Varenikov, A.; Vostrukhin, A.; Zeitlin, C.

    2015-12-01

    The Dynamic Albedo of Neutrons (DAN) experiment on the Mars Science Laboratory (MSL) rover Curiosity is designed to detect neutrons to determine hydrogen abundance within the subsurface of Mars (Mitrofanov, I.G. et al. [2012]. Space Sci. Rev. 170, 559-582. http://dx.doi.org/10.1007/s11214-012-9924-y; Litvak, M.L. et al. [2008]. Astrobiology 8, 605-613. http://dx.doi.org/10.1089/ast.2007.0157). While DAN has a pulsed neutron generator for active measurements, in passive mode it only measures the leakage spectrum of neutrons produced by the Multi-Mission Radioisotope Thermoelectric Generator (MMRTG) and Galactic Cosmic Rays (GCR). DAN passive measurements provide better spatial coverage than the active measurements because they can be acquired while the rover is moving. Here we compare DAN passive-mode data to models of the instrument's response to compositional differences in a homogeneous regolith in order to estimate the water equivalent hydrogen (WEH) content along the first 200 sols of Curiosity's traverse in Gale Crater, Mars. WEH content is shown to vary greatly along the traverse. These estimates range from 0.5 ± 0.1 wt.% to 3.9 ± 0.2 wt.% for fixed locations (usually overnight stops) investigated by the rover and 0.6 ± 0.2 wt.% to 7.6 ± 1.3 wt.% for areas that the rover has traversed while continuously acquiring DAN passive data between fixed locations. Estimates of WEH abundances at fixed locations based on passive mode data are in broad agreement with those estimated at the same locations using active mode data. Localized (meter-scale) anomalies in estimated WEH values from traverse measurements have no particular surface expression observable in co-located images. However at a much larger scale, the hummocky plains and bedded fractured units are shown to be distinct compositional units based on the hydrogen content derived from DAN passive measurements. DAN passive WEH estimates are also shown to be consistent with geologic models inferred from other MSL instruments, which indicate that fluvial/lacustrine activity occurred at certain locations (e.g., Yellowknife Bay).

  1. Effect of thumb joint mobilization on pressure pain threshold in elderly patients with thumb carpometacarpal osteoarthritis.

    PubMed

    Villafañe, Jorge H; Silva, Guillermo B; Fernandez-Carnero, Josue

    2012-02-01

    This study evaluated the effects of Maitland's passive accessory mobilization on local hypoalgesia and strength in thumb carpometacarpal osteoarthritis (TCOA). Twenty-eight patients between 70 and 90 years old with secondary TCOA were randomized into glide mobilization and sham groups. This study was designed as a double-blind, randomized controlled trial. Therapy consisted of Maitland's passive accessory mobilization of the dominant hand during 4 sessions over 2 weeks. We measured pressure pain threshold (PPT) at the trapeziometacarpal joint (TMJ), the tubercle of the scaphoid bone, and the unciform apophysis of the hamate bone by algometry. The tip and tripod pinch strength was also measured. Grip strength was measured by a grip dynamometer. Measurements were taken before treatment and after 1 week (first follow-up [FU]) and 2 weeks (second FU). All values in sham group remained unchanged along the treatment period. In the treated group, the PPT in the TMJ was 3.85 ± 0.35 kg/cm(2), which increased after treatment to 3.99 ± 0.37 and was maintained at the same level during the first FU 3.94 ± 0.39 and second FU 4.74 ± 0.40. In contrast, we found no differences in PPT in the other studied structures after treatment. Similarly, tip, tripod pinch, and grip strength remained without change after treatment. Passive accessory mobilization increased PPT in the TMJ; however, it did not increase motor function in patients with TCOA. Copyright © 2012 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.

  2. Orion Passive Thermal Control Overview

    NASA Technical Reports Server (NTRS)

    Miller, Stephen W.

    2007-01-01

    An viewgraph presentation of Orion's passive thermal control system is shown. The topics include: 1) Orion in CxP Hierarchy; 2) General Orion Description/Orientation; 3) Module Descriptions and Images; 4) Orion PTCS Overview; 5) Requirements/Interfaces; 6) Design Reference Missions; 7) Natural Environments; 8) Thermal Models; 9) Challenges/Issues; and 10) Testing

  3. Ge{sub 0.83}Sn{sub 0.17} p-channel metal-oxide-semiconductor field-effect transistors: Impact of sulfur passivation on gate stack quality

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lei, Dian; Wang, Wei; Gong, Xiao, E-mail: elegong@nus.edu.sg, E-mail: yeo@ieee.org

    2016-01-14

    The effect of room temperature sulfur passivation of the surface of Ge{sub 0.83}Sn{sub 0.17} prior to high-k dielectric (HfO{sub 2}) deposition is investigated. X-ray photoelectron spectroscopy (XPS) was used to examine the chemical bonding at the interface of HfO{sub 2} and Ge{sub 0.83}Sn{sub 0.17}. Sulfur passivation is found to be effective in suppressing the formation of both Ge oxides and Sn oxides. A comparison of XPS results for sulfur-passivated and non-passivated Ge{sub 0.83}Sn{sub 0.17} samples shows that sulfur passivation of the GeSn surface could also suppress the surface segregation of Sn atoms. In addition, sulfur passivation reduces the interface trapmore » density D{sub it} at the high-k dielectric/Ge{sub 0.83}Sn{sub 0.17} interface from the valence band edge to the midgap of Ge{sub 0.83}Sn{sub 0.17}, as compared with a non-passivated control. The impact of the improved D{sub it} is demonstrated in Ge{sub 0.83}Sn{sub 0.17} p-channel metal-oxide-semiconductor field-effect transistors (p-MOSFETs). Ge{sub 0.83}Sn{sub 0.17} p-MOSFETs with sulfur passivation show improved subthreshold swing S, intrinsic transconductance G{sub m,int}, and effective hole mobility μ{sub eff} as compared with the non-passivated control. At a high inversion carrier density N{sub inv} of 1 × 10{sup 13 }cm{sup −2}, sulfur passivation increases μ{sub eff} by 25% in Ge{sub 0.83}Sn{sub 0.17} p-MOSFETs.« less

  4. Load attenuating passively adaptive wind turbine blade

    DOEpatents

    Veers, Paul S.; Lobitz, Donald W.

    2003-01-07

    A method and apparatus for improving wind turbine performance by alleviating loads and controlling the rotor. The invention employs the use of a passively adaptive blade that senses the wind velocity or rotational speed, and accordingly modifies its aerodynamic configuration. The invention exploits the load mitigation prospects of a blade that twists toward feather as it bends. The invention includes passively adaptive wind turbine rotors or blades with currently preferred power control features. The apparatus is a composite fiber horizontal axis wind-turbine blade, in which a substantial majority of fibers in the blade skin are inclined at angles of between 15 and 30 degrees to the axis of the blade, to produces passive adaptive aeroelastic tailoring (bend-twist coupling) to alleviate loading without unduly jeopardizing performance.

  5. Load attenuating passively adaptive wind turbine blade

    DOEpatents

    Veers, Paul S.; Lobitz, Donald W.

    2003-01-01

    A method and apparatus for improving wind turbine performance by alleviating loads and controlling the rotor. The invention employs the use of a passively adaptive blade that senses the wind velocity or rotational speed, and accordingly modifies its aerodynamic configuration. The invention exploits the load mitigation prospects of a blade that twists toward feather as it bends. The invention includes passively adaptive wind turbine rotors or blades with currently preferred power control features. The apparatus is a composite fiber horizontal axis wind-turbine blade, in which a substantial majority of fibers in the blade skin are inclined at angles of between 15 and 30 degrees to the axis of the blade, to produces passive adaptive aeroelastic tailoring (bend-twist coupling) to alleviate loading without unduly jeopardizing performance.

  6. Some comments on passive microwave measurement of rain

    NASA Technical Reports Server (NTRS)

    Wilheit, Thomas T.

    1986-01-01

    It is argued that because microwave radiation interacts much more strongly with hydrometeors than with cloud particles, microwave measurements from space offer a significant chance of making global precipitation estimates. Over oceans, passive microwave measurements are essentially attenuation measurements that can be very closely related to the rain rate independently of the details of the drop-size distribution. Over land, scattering of microwave radiation by the hydrometeors, especially in the ice phase, can be used to estimate rainfall. In scattering, the details of the drop-size distribution are very important and it is therefore more difficult to achieve a high degree of accuracy. The SSM/I (Special Sensor Microwave Imager), a passive microwave imaging sensor that will be launched soon, will have dual-polarized channels at 85.5 GHz that will be very sensitive to scattering by frozen hydrometeors. Other sensors being considered for the future space missions would extend the ability to estimate rain rates from space. The ideal spaceborne precipitation-measurement system would use the complementary strengths of passive microwave, radar, and visible/infrared measurements.

  7. Evaluating the Relationship between Equilibrium Passive Sampler Uptake and Aquatic Organism Bioaccumulation (IPSW)

    EPA Science Inventory

    This review evaluates passive sampler uptake of hydrophobic organic contaminants (HOCs) as it relates to organism bioaccumulation in the water column and interstitial water. Fifty-five studies were found where both passive samplers and organism bioaccumulation were used to measur...

  8. RADON MITIGATION EFFECTS OF PASSIVE STACKS IN RESIDENTIAL NEW CONSTRUCTION

    EPA Science Inventory

    The paper discusses the effects of passive stacks in mitigating radon levels in residential new construction. Although passive stacks have been installed as a radon resistant measure in new houses, little quantitative data on their performance has been collected. This study invol...

  9. Symptom profile of multiple chemical sensitivity in actual life.

    PubMed

    Saito, Mariko; Kumano, Hiroaki; Yoshiuchi, Kazuhiro; Kokubo, Naomi; Ohashi, Kyoko; Yamamoto, Yoshiharu; Shinohara, Naohide; Yanagisawa, Yukio; Sakabe, Kou; Miyata, Mikio; Ishikawa, Satoshi; Kuboki, Tomifusa

    2005-01-01

    This study was conducted to confirm the definition of multiple chemical sensitivity (MCS) in actual life: that multiple symptoms are provoked in multiple organs by exposure to, and ameliorated by avoidance of, multiple chemicals at low levels. We used the Ecological Momentary Assessment to monitor everyday symptoms and the active sampling and passive sampling methods to measure environmental chemical exposure. Eighteen patients with MCS, diagnosed according to the 1999 consensus criteria, and 12 healthy controls participated in this study. Fourteen patients and 12 controls underwent 1-week measurement of physical and psychologic symptoms and of the levels of exposure to various chemicals. Linear mixed models were used to test the hypotheses regarding the symptom profile of MCS patients. Some causative chemicals were detected in 11 of 14 MCS patients. Two other patients did not report any hypersensitivity episodes, whereas passive sampling showed far less exposure to chemicals than control subjects. Another subject reported episodic symptoms but was excluded from the following analyses because no possible chemical was detected. Eleven of the 17 physical symptoms and all four mood subscales examined were significantly aggravated in the interview based on "patient-initiated symptom prompts." On the other hand, there were no differences in physical symptoms or mood subscales between MCS patients and control subjects in the interview based on "random prompts." MCS patients do not have either somatic or psychologic symptoms under chemical-free conditions, and symptoms may be provoked only when exposed to chemicals.

  10. Induced conductivity in sol-gel ZnO films by passivation or elimination of Zn vacancies

    NASA Astrophysics Data System (ADS)

    Winarski, D. J.; Anwand, W.; Wagner, A.; Saadatkia, P.; Selim, F. A.; Allen, M.; Wenner, B.; Leedy, K.; Allen, J.; Tetlak, S.; Look, D. C.

    2016-09-01

    Undoped and Ga- and Al- doped ZnO films were synthesized using sol-gel and spin coating methods and characterized by X-ray diffraction, high-resolution scanning electron microscopy (SEM), optical spectroscopy and Hall-effect measurements. SEM measurements reveal an average grain size of 20 nm and distinct individual layer structure. Measurable conductivity was not detected in the unprocessed films; however, annealing in hydrogen or zinc environment induced significant conductivity (˜10-2 Ω .cm) in most films. Positron annihilation spectroscopy measurements provided strong evidence that the significant enhancement in conductivity was due to hydrogen passivation of Zn vacancy related defects or elimination of Zn vacancies by Zn interstitials which suppress their role as deep acceptors. Hydrogen passivation of cation vacancies is shown to play an important role in tuning the electrical conductivity of ZnO, similar to its role in passivation of defects at the Si/SiO2 interface that has been essential for the successful development of complementary metal-oxide-semiconductor (CMOS) devices. By comparison with hydrogen effect on other oxides, we suggest that hydrogen may play a universal role in oxides passivating cation vacancies and modifying their electronic properties.

  11. Effects of Passive Physical Exercise on Peripheral Vision in Muscular Dystrophic Children.

    ERIC Educational Resources Information Center

    Eickelberg, Warren; And Others

    1983-01-01

    The effects of passive exercise of the extremities on peripheral vision of muscular dystrophic children aged 9 to 13 years was investigated. Compared to control subjects, those who experienced six minutes of passive exercise evidenced increased peripheral vision. Curriculum revisions for muscular dystrophic children indicate the importance of…

  12. Controlled motion in an elastic world. Research project: Manipulation strategies for massive space payloads

    NASA Technical Reports Server (NTRS)

    Book, Wayne J.

    1992-01-01

    The flexibility of the drives and structures of controlled motion systems are presented as an obstacle to be overcome in the design of high performance motion systems, particularly manipulator arms. The task and the measure of performance to be applied determine the technology appropriate to overcome this obstacle. Included in the technologies proposed are control algorithms (feedback and feed forward), passive damping enhancement, operational strategies, and structural design. Modeling of the distributed, nonlinear system is difficult, and alternative approaches are discussed. The author presents personal perspectives on the history, status, and future directions in this area.

  13. Changes in Passive Tension of the Hamstring Muscles During a Simulated Soccer Match.

    PubMed

    Marshall, Paul W; Lovell, Ric; Siegler, Jason C

    2016-07-01

    Passive muscle tension is increased after damaging eccentric exercise. Hamstring-strain injury is associated with damaging eccentric muscle actions, but no research has examined changes in hamstring passive muscle tension throughout a simulated sport activity. The authors measured hamstring passive tension throughout a 90-min simulated soccer match (SAFT90), including the warm-up period and every 15 min throughout the 90-min simulation. Passive hamstring tension of 15 amateur male soccer players was measured using the instrumented straight-leg-raise test. Absolute torque (Nm) and slope (Nm/°) of the recorded torque-angular position curve were used for data analysis, in addition to total leg range of motion (ROM). Players performed a 15-min prematch warm-up, then performed the SAFT90 including a 15-min halftime rest period. Reductions in passive stiffness of 20-50° of passive hip flexion of 22.1-29.2% (P < .05) were observed after the warm-up period. During the SAFT90, passive tension increased in the latter 20% of the range of motion of 10.1-10.9% (P < .05) concomitant to a 4.5% increase in total hamstring ROM (P = .0009). The findings of this study imply that hamstring passive tension is reduced after an active warm-up that includes dynamic stretching but does not increase in a pattern suggestive of eccentric induced muscle damage during soccer-specific intermittent exercise. Hamstring ROM and passive tension increases are best explained by improved stretch tolerance.

  14. Investigation of sulfonated polysulfone membranes as electrolyte in a passive-mode direct methanol fuel cell mini-stack

    NASA Astrophysics Data System (ADS)

    Lufrano, F.; Baglio, V.; Staiti, P.; Stassi, A.; Aricò, A. S.; Antonucci, V.

    This paper reports on the development of polymer electrolyte membranes (PEMs) based on sulfonated polysulfone for application in a DMFC mini-stack operating at room temperature in passive mode. The sulfonated polysulfone (SPSf) with two degrees of sulfonation (57 and 66%) was synthesized by a well-known sulfonation process. SPSf membranes with different thicknesses were prepared and investigated. These membranes were characterized in terms of methanol/water uptake, proton conductivity, and fuel cell performance in a DMFC single cell and mini-stack operating at room temperature. The study addressed (a) control of the synthesis of sulfonated polysulfone, (b) optimization of the assembling procedure, (c) a short lifetime investigation and (d) a comparison of DMFC performance in active-mode operation vs. passive-mode operation. The best passive DMFC performance was 220 mW (average cell power density of about 19 mW cm -2), obtained with a thin SPSf membrane (70 μm) at room temperature, whereas the performance of the same membrane-based DMFC in active mode was 38 mW cm -2. The conductivity of this membrane, SPSf (IEC = 1.34 mequiv. g -1) was 2.8 × 10 -2 S cm -1. A preliminary short-term test (200 min) showed good stability during chrono-amperometry measurements.

  15. Cost-benefit analysis of passive fire protections in road LPG transportation.

    PubMed

    Paltrinieri, Nicola; Bonvicini, Sarah; Spadoni, Gigliola; Cozzani, Valerio

    2012-02-01

    The cost-benefit evaluation of passive fire protection adoption in the road transport of liquefied petroleum gas (LPG) was investigated. In a previous study, mathematical simulations of real scale fire scenarios proved the effectiveness of passive fire protections in preventing the "fired" boiling liquid expanding vapor explosion (BLEVE), thus providing a significant risk reduction. In the present study the economical aspects of the adoption of fire protections are analyzed and an approach to cost-benefit analysis (CBA) is proposed. The CBA model is based on the comparison of the risk reduction due to fire protections (expressed in monetary terms by the value of a statistical life) and the cost of the application of fire protections to a fleet of tankers. Different types of fire protections were considered, as well as the possibility to apply protections to the entire fleet or only to a part of it. The application of the proposed model to a real-life case study is presented and discussed. Results demonstrate that the adoption of passive fire protections on road tankers, though not compulsory in Europe, can be economically feasible, thus representing a concrete measure to achieve control of the "major hazard accidents" cited by the European legislation. © 2011 Society for Risk Analysis.

  16. Impact of Active Control on Passive Safety Response Characteristics of Sodium-Cooled Fast Reactors: II-Model Implementation and Simulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ponciroli, Roberto; Passerini, Stefano; Vilim, Richard B.

    Advanced reactors are often claimed to be passively safe against unprotected upset events. In common practice, these events are not considered in the context of the plant control system, i.e., the reactor is subjected to classes of unprotected upset events while the normally programmed response of the control system is assumed not to be present. However, this approach constitutes an oversimplification since, depending on the upset involving the control system, an actuator does not necessarily go in the same direction as needed for safety. In this work, dynamic simulations are performed to assess the degree to which the inherent self-regulatingmore » plant response is safe from active control system override. The simulations are meant to characterize the resilience of the plant to unprotected initiators. The initiators were represented and modeled as an actuator going to a hard limit. Consideration of failure is further limited to individual controllers as there is no cross-connect of signals between these controllers. The potential for passive safety override by the control system is then relegated to the single-input single-output controllers. Here, the results show that when the plant control system is designed by taking into account and quantifying the impact of the plant control system on accidental scenarios there is very limited opportunity for the preprogrammed response of the control system to override passive safety protection in the event of an unprotected initiator.« less

  17. Impact of Active Control on Passive Safety Response Characteristics of Sodium-Cooled Fast Reactors: II-Model Implementation and Simulations

    DOE PAGES

    Ponciroli, Roberto; Passerini, Stefano; Vilim, Richard B.

    2017-06-21

    Advanced reactors are often claimed to be passively safe against unprotected upset events. In common practice, these events are not considered in the context of the plant control system, i.e., the reactor is subjected to classes of unprotected upset events while the normally programmed response of the control system is assumed not to be present. However, this approach constitutes an oversimplification since, depending on the upset involving the control system, an actuator does not necessarily go in the same direction as needed for safety. In this work, dynamic simulations are performed to assess the degree to which the inherent self-regulatingmore » plant response is safe from active control system override. The simulations are meant to characterize the resilience of the plant to unprotected initiators. The initiators were represented and modeled as an actuator going to a hard limit. Consideration of failure is further limited to individual controllers as there is no cross-connect of signals between these controllers. The potential for passive safety override by the control system is then relegated to the single-input single-output controllers. Here, the results show that when the plant control system is designed by taking into account and quantifying the impact of the plant control system on accidental scenarios there is very limited opportunity for the preprogrammed response of the control system to override passive safety protection in the event of an unprotected initiator.« less

  18. Cotinine analytical workshop report: consideration of analytical methods for determining cotinine in human body fluids as a measure of passive exposure to tobacco smoke.

    PubMed Central

    Watts, R R; Langone, J J; Knight, G J; Lewtas, J

    1990-01-01

    A two-day technical workshop was convened November 10-11, 1986, to discuss analytical approaches for determining trace amounts of cotinine in human body fluids resulting from passive exposure to environmental tobacco smoke (ETS). The workshop, jointly sponsored by the U.S. Environmental Protection Agency and Centers for Disease Control, was attended by scientists with expertise in cotinine analytical methodology and/or conduct of human monitoring studies related to ETS. The workshop format included technical presentations, separate panel discussions on chromatography and immunoassay analytical approaches, and group discussions related to the quality assurance/quality control aspects of future monitoring programs. This report presents a consensus of opinion on general issues before the workshop panel participants and also a detailed comparison of several analytical approaches being used by the various represented laboratories. The salient features of the chromatography and immunoassay analytical methods are discussed separately. PMID:2190812

  19. Passive smoking in babies: The BIBE study (Brief Intervention in babies. Effectiveness)

    PubMed Central

    2010-01-01

    Background There is evidence that exposure to passive smoking in general, and in babies in particular, is an important cause of morbimortality. Passive smoking is related to an increased risk of pediatric diseases such as sudden death syndrome, acute respiratory diseases, worsening of asthma, acute-chronic middle ear disease and slowing of lung growth. The objective of this article is to describe the BIBE study protocol. The BIBE study aims to determine the effectiveness of a brief intervention within the context of Primary Care, directed to mothers and fathers that smoke, in order to reduce the exposure of babies to passive smoking (ETS). Methods/Design Cluster randomized field trial (control and intervention group), multicentric and open. Subject: Fathers and/or mothers who are smokers and their babies (under 18 months) that attend pediatric services in Primary Care in Catalonia. The measurements will be taken at three points in time, in each of the fathers and/or mothers who respond to a questionnaire regarding their baby's clinical background and characteristics of the baby's exposure, together with variables related to the parents' tobacco consumption. A hair sample of the baby will be taken at the beginning of the study and at six months after the initial visit (biological determination of nicotine). The intervention group will apply a brief intervention in passive smoking after specific training and the control group will apply the habitual care. Discussion Exposure to ETS is an avoidable factor related to infant morbimortality. Interventions to reduce exposure to ETS in babies are potentially beneficial for their health. The BIBE study evaluates an intervention to reduce exposure to ETS that takes advantage of pediatric visits. Interventions in the form of advice, conducted by pediatric professionals, are an excellent opportunity for prevention and protection of infants against the harmful effects of ETS. Trial Registration Clinical Trials.gov Identifier: NCT00788996. PMID:21171981

  20. Control of Stationary Cross-Flow Modes in a Mach 3.5 Boundary Layer Using Patterned Passive and Active Roughness

    NASA Technical Reports Server (NTRS)

    Schuele, Chan Yong

    2011-01-01

    Spanwise-periodic roughness designed to excite selected wavelengths of stationary cross- ow modes was investigated in a 3-D boundary layer at Mach 3.5. The test model was a sharp-tipped 14deg right-circular cone. The model and integrated sensor traversing system were placed in the Mach 3.5 Supersonic Low Disturbance Tunnel (SLDT) equipped with a "quiet design" nozzle at the NASA Langley Research Center. The model was oriented at a 4:2deg angle of attack to produce a mean cross-fl ow velocity component in the boundary layer over the cone. Five removable cone tips have been investigated. One has a smooth surface that is used to document the baseline ("natural") conditions. Two had minute (20 - 40 micron) "dimples" that are equally spaced around the circumference, at a streamwise location that is just upstream of the linear stability neutral growth branch for cross- ow modes. The azimuthal mode numbers of the dimpled tips were selected to either enhance the most amplified wave numbers, or to suppress the growth of the most amplified wave numbers. Two of the cone tips had an array of plasma streamwise vortex generators that were designed to simulate the disturbances produced by the passive patterned roughness. The results indicate that the stationary cross-fl ow modes were highly receptive to the patterned roughness of both passive and active types. The patterned passive roughness that was designed to suppress the growth of the most amplified modes had an azimuthal wavelength that was 66% smaller that that of the most amplified stationary cross- ow mode. This had the effect to increase the transition Reynolds number from 25% to 50% depending on the measurement technique. The application of the research is on turbulent transition control on swept wings of supersonic aircraft. The plasma-based roughness has the advantage over the passive roughness of being able to be adaptable to different conditions that would occur during a flight mission.

  1. Comparison of analytical and wind-tunnel results for flutter and gust response of a transport wing with active controls

    NASA Technical Reports Server (NTRS)

    Abel, I.; Perry, B., III; Newsom, J. R.

    1982-01-01

    Two flutter suppression control laws wre designed and tested on a low speed aeroelastic model of a DC-10 derivative wing. Both control laws demontrated increases in flutter speed in excess of 25 percent above the passive wing flutter speed. In addition, one of the control laws was effective in reducing loads due to turbulence generated in the wind tunnel. The effect of variations in gain and phase on the closed-loop performance was measured and is compared with predictions. In general, both flutter and gust response predictions agree reasonably well with experimental data.

  2. Nicotine cut-off value in human hair as a tool to distinguish active from passive smokers: A cross-sectional study in Japanese men.

    PubMed

    Tsuji, Masayoshi; Kanda, Hideyuki; Hayakawa, Takehito; Mori, Yayoi; Ito, Teruna; Hidaka, Tomoo; Kakamu, Takeyasu; Kumagai, Tomohiro; Osaki, Yoneatsu; Kawazoe, Miki; Sato, Sei; Fukushima, Tetsuhito

    2017-07-19

    Nicotine concentration in hair is a useful marker of tobacco exposure. Detection of nicotine in the hair of non-smokers indicates passive smoking. Accurate measurement of nicotine among active and passive smokers can help in smoking cessation programs or programs designed to prevent secondhand smoke exposure. To establish, using high-performance liquid chromatography-ultraviolet detection (HPLC/UV), a hair nicotine cut-off value to distinguish active from passive smokers. Hair samples were collected from randomly chosen Japanese men (n= 192) between 2009 and 2011. Nicotine and cotinine levels in hair were measured using HPLC/UV with column-switching. T-tests and chi-square tests were performed to compare active and passive smokers, while receiver operating characteristic curves were used to evaluate the effectiveness of the cut-off value. There were 69 active smokers and 123 passive smokers. The nicotine and cotinine concentrations in hair were significantly higher in active than in passive smokers (p< 0.01). The area under the curve for nicotine was 0.92. A hair nicotine cut-off value of 5.68 ng/mg, with a sensitivity of 94.2% and specificity of 87.0%, was identified as the optimal cut-off value for separating active from passive smokers. Nicotine and cotinine concentrations in hair clearly distinguished active from passive smokers.

  3. Survival and growth of age-0 steelhead after surgical implantation of 23-mm passive integrated transponders

    USGS Publications Warehouse

    Bateman, D.S.; Gresswell, R.E.

    2006-01-01

    Little information is available on the effects of implanting 23-mm passive integrated transponder (PIT) tags in salmonids less than 90 mm fork length (FL). Using juvenile steelhead Oncorhynchus mykiss (range, 73–97 mm FL), we compared instantaneous growth rates and survival among three experimental groups: control, surgery with no tag, and surgery with tag. Survival rate was lower for tagged fish (86%) than for control and surgery−no tag fish (virtually 100% in each group). Approximately 90% of the mortalities occurred during days 1–3. Growth rate for the tagged group was lower for the first two 10-d measurement intervals; however, during the third 10-d interval, growth rates for tagged fish equaled or exceeded values for the other groups. These results suggest that tagged fish recovered by day 20. Growth rates for the control and surgery−no tag groups did not differ from one another during any measurement interval. Tag retention rate was 97% over the 30-d period of the study. It appears that the combination of fish length and tag size in this study resulted in short-term negative effects on growth rate and survival; however, 23-mm PIT tags may still be useful for studies of salmonids 80–90 mm FL when survival is not the parameter of interest.

  4. Microwave remote sensing of sea ice in the AIDJEX Main Experiment. [Arctic Ice Dynamics Joint Experiment

    NASA Technical Reports Server (NTRS)

    Campbell, W. J.; Wayenberg, J.; Ramseyer, J. B.; Ramseier, R. O.; Vant, M. R.; Weaver, R.; Redmond, A.; Arsenault, L.; Gloersen, P.; Zwally, H. J.

    1978-01-01

    A microwave remote sensing program of sea ice in the Beaufort Sea was conducted during the Arctic Ice Dynamics Joint Experiment (AIDJEX). Several types of both passive and active sensors were used to perform surface and aircraft measurements during all seasons of the year. In situ observations were made of physical properties (salinity, temperature, density, surface roughness), dielectric properties, and passive microwave measurements were made of first-year, multiyear, and first-year/multiyear mixtures. Airborne passive microwave measurements were performed with the electronically scanning microwave radiometer while airborne active microwave measurements were performed by synthetic aperture radar, X- and L-band radar, and a scatterometer.

  5. Deriving sediment Interstitial Water Remediation Goals (IWRGs) for the protection of benthic organisms from direct toxicity

    EPA Science Inventory

    Background/Objectives. Passive sampling is becoming a frequently used measurement technique at Superfund sites with contaminated sediments. Passive sampling measures the concentrations of freely dissolved chemicals (Cfrees) in the sediment interstitial water. The freely dissol...

  6. South Philadelphia Passive Sampler and Sensor Study

    EPA Science Inventory

    Starting in June 2013, the United States Environmental Protection Agency (U.S. EPA) and the City of Philadelphia Air Measurements Services began collaborative research on the use of passive samplers (PSs) and stand-alone air measurement (SAM) systems to improve information on the...

  7. THE IMPACT OF PASSIVE SAMPLING METHODOLOGIES USED IN THE DEARS

    EPA Science Inventory

    This abstract details the use of passive sampling methodologies in the Detroit Exposure and Aerosol Research Study (DEARS). A discussion about the utility of various gas-phase passive samplers used in the study will be described along with examples of field data measurements empl...

  8. Advances in the epidemiology of injuries as a basis for public policy.

    PubMed Central

    Haddon, W

    1980-01-01

    Successful injury control measures (stoplights, sprinkler systems, electrical insulation, evacuation) have long been commonplace. However, progress in injury control has been hampered by the failure to recognize that injuries cannot occur without the action of specific agents analogous to those of the infectious diseases and likewise transmitted by vehicles and vectors. These agents are the several forms of injury. Varying and interacting with the characteristics of the host and the environment, they constitute the classic epidemiologic triads that determine injury distributions, none of which are random. The injury-disease dichotomy, a universal in most of the world's major languages, may have resulted from the fact that at least some of the causes of injuries (for example, wild animals or falling trees) are more identifiable and proximate than the causes of diseases. The etiology of injuries suggests that for epidemiologic and public health purposes, the term injury should probably be defined so as to encompass those kinds of damage to the body that are produced by energy exchanges and that are manifested within 48 hours, or usually within considerably shorter periods. Strategies for injury control can be extended to the control of other pathological conditions. The active-passive distinction (the dimension expressing the extent to which control measures require people to do something) has a direct bearing on the success of public health programs, because passive approaches have historically had a far better record of success than active ones. Ten basic strategies have been identified that provide options for reducing the damage to people (and property) caused by all kinds of environmental hazards. PMID:7422807

  9. Error in measuring radon in soil gas by means of passive detectors

    USGS Publications Warehouse

    Tanner, A.B.

    1991-01-01

    Passive detection of radon isotopes depends on diffusion of radon atoms from the sites of their generation to the location of the detecting or collecting device. Because some radon decays en route to a passive detector in soil, the radon concentration measured by the detector must be less than the concentration in those soil pores where it is undiminished by diffusion to the detector cavity. The true radon concentration may be significantly underestimated in moist soils. -Author

  10. The 4-8 GHz Microwave Active and Passive Spectrometer (MAPS). Volume 1: Radar section

    NASA Technical Reports Server (NTRS)

    Ulaby, F. T.

    1973-01-01

    The performance characteristics of the radar section of the prototype 4-8 GHz Microwave Active and Passive Spectrometer system are reported. Active and passive spectral responses were measured of natural, cultivated, and human-made surfaces over the 4-18 GHz region of frequencies for look angles between zero and 70 degrees and for all possible linear polarization combinations. Soil and plant samples were collected to measure their dielectric properties and moisture content. The FORTRAN program for area calculation is provided.

  11. Measurements of the radiation dose to LDEF by means of passive dosimetry

    NASA Astrophysics Data System (ADS)

    Blake, J. B.; Imamoto, S. S.

    1992-06-01

    A very simple experiment was fielded on LDEF to measure the energetic radiation dose by means of passive dosimetry. It consisted of two identical packets of 16 LiF thermoluminescent dosimeters (TLD) arranged in planar arrays. One array was placed on the leading edge of the spacecraft, the other on the trailing edge. These arrays were installed in opaque packets of 1 mil Al foil and Kapton tape mounted behind an Al plate of 30 mils thickness. The nominal energy thresholds were 14 MeV for protons and 650 keV for electrons. In addition to the flight arrays, two control arrays were prepared which were kept with the flight arrays as long as possible during experimental integration and then stored in the lab. The flight and control arrays were read out alternating in groups of four; it was found that the control dose was negligible. The flight and control detectors were exposed to a 55 MeV proton beam in order to provide a recalibration of the detectors. It was found that the post-flight and pre-flight calibrations were in good agreement. A comparison of results with the prediction shows that the measured dose was a factor of 4 to 5 low. It is possible that there was in-flight annealing of the TLDs as a result of the long mission and perhaps temperature excursions of the sensors. The East-West effect was larger than expected. The ratio of 1.65 is approximately what was expected for the protons alone. Electrons should reduce the dose ratio since electrons add equally to the leading and trailing edge dose. A possible explanation is that the electron dose was negligible compared to the proton dose.

  12. Measurements of the radiation dose to LDEF by means of passive dosimetry

    NASA Technical Reports Server (NTRS)

    Blake, J. B.; Imamoto, S. S.

    1992-01-01

    A very simple experiment was fielded on LDEF to measure the energetic radiation dose by means of passive dosimetry. It consisted of two identical packets of 16 LiF thermoluminescent dosimeters (TLD) arranged in planar arrays. One array was placed on the leading edge of the spacecraft, the other on the trailing edge. These arrays were installed in opaque packets of 1 mil Al foil and Kapton tape mounted behind an Al plate of 30 mils thickness. The nominal energy thresholds were 14 MeV for protons and 650 keV for electrons. In addition to the flight arrays, two control arrays were prepared which were kept with the flight arrays as long as possible during experimental integration and then stored in the lab. The flight and control arrays were read out alternating in groups of four; it was found that the control dose was negligible. The flight and control detectors were exposed to a 55 MeV proton beam in order to provide a recalibration of the detectors. It was found that the post-flight and pre-flight calibrations were in good agreement. A comparison of results with the prediction shows that the measured dose was a factor of 4 to 5 low. It is possible that there was in-flight annealing of the TLDs as a result of the long mission and perhaps temperature excursions of the sensors. The East-West effect was larger than expected. The ratio of 1.65 is approximately what was expected for the protons alone. Electrons should reduce the dose ratio since electrons add equally to the leading and trailing edge dose. A possible explanation is that the electron dose was negligible compared to the proton dose.

  13. Evaluating the Relationship between Equilibrium Passive ...

    EPA Pesticide Factsheets

    Objectives. This review evaluates passive sampler uptake of hydrophobic organic contaminants (HOCs) in water column and interstitial water exposures as a surrogate for organism bioaccumulation. Approach/Activities. Fifty-five studies were found where both passive sampler uptake and organism bioaccumulation were measured and 19 of these investigations provided direct comparisons relating passive sampler uptake and organism bioaccumulation. Polymers compared included low density polyethylene (LDPE), polyoxymethylene (POM), and polydimethylsiloxane (PDMS), and organisms ranged from polychaetes and oligochaetes to bivalves, aquatic insects, and gastropods. Regression equations correlating bioaccumulation (CL) and passive sampler uptake (CPS) were used to assess the strength of observed relationships. Results/Lessons Learned. Passive sampling based concentrations resulted in strong logarithmic regression relationships, most of which were within one to two orders of magnitude of measured bioaccumulation. Mean coefficients of determination (r2) for LDPE, PDMS and POM were 0.68, 0.76 and 0.58, respectively. For the available raw data, the mean ratio of CL and CPS was 10.8 ± 18.4 (n = 609). Passive sampler uptake and bioaccumulation were not found to be identical (i.e., CPS ≠ CL) but the logarithmic-based relationships between these values were consistently linear and predictive. This review concludes that in many applications passive sampling may serve as a

  14. Target detection using microwave irradiances from natural sources: A passive, local and global surveillance system

    NASA Technical Reports Server (NTRS)

    Stacey, J. M.

    1984-01-01

    Detection of metal objects on or near the Earth's surface was investigated using existing, passive, microwave sensors operating from Earth orbit. The range equations are derived from basic microwave principles and theories and the expressions are given explicitly to estimate the signal to noise ratio for detecting metal targets operating as bistatic scatterers. Actual measurements are made on a range of metal objects observed from orbit using existing passive microwave receiving systems. The details of the measurements and the results are tabulated and discussed. The advantages of a passive microwave sensor as it is applied to surveillance of metal objects as viewed from aerial platforms or from orbit, are examined.

  15. A hybrid active/passive exhaust noise control system for locomotives.

    PubMed

    Remington, Paul J; Knight, J Scott; Hanna, Doug; Rowley, Craig

    2005-01-01

    A prototype hybrid system consisting of active and passive components for controlling far-field locomotive exhaust noise has been designed, assembled, and tested on a locomotive. The system consisted of a resistive passive silencer for controlling high-frequency broadband noise and a feedforward multiple-input, multiple-output active control system for suppressing low-frequency tonal noise. The active system used ten roof-mounted bandpass speaker enclosures with 2-12-in. speakers per enclosure as actuators, eight roof-mounted electret microphones as residual sensors, and an optical tachometer that sensed locomotive engine speed as a reference sensor. The system was installed on a passenger locomotive and tested in an operating rail yard. Details of the system are described and the near-field and far-field noise reductions are compared against the design goal.

  16. Passive Isolators for use on the International Space Station

    NASA Technical Reports Server (NTRS)

    Houston, Janice; Gattis, Christy

    2003-01-01

    The value of the International Space Station (ISS) as a premier microgravity environment is currently at risk due to structure-borne vibration. The vibration sources are varied and include crew activities such as exercising or simply moving from module to module, and electro- mechanical equipment such as fans and pumps. Given such potential degradation of usable microgravity, anything that can be done to dampen vibration on-orbit will significantly benefit microgravity users. Most vibration isolation schemes, both active and passive, have proven to be expensive - both operationally and from the cost of integrating isolation systems into primary/secondary structural interfaces (e.g., the ISS module/rack interface). Recently, passively absorptive materials have been tested at the bolt interfaces between the operating equipment and support structure (secondary/tertiary structural interfaces). The results indicate that these materials may prove cost-effective in mitigating the vibrational problems of the ISS. We report herein tests of passive absorbers placed at the interface of a vibration-inducing component: the Development Distillation Assembly, a subassembly of the Urine Processing Assembly, which is a rotating centrifuge and cylinder assembly attached to a mounting plate. Passive isolators were installed between this mounting plate and its support shelf. Three materials were tested: BISCO HT-800, Sorbothane 30 and Sorbothane 50, plus a control test with a hard shim. In addition, four distinct combinations of the HT-800 and Sorbothane 50 were tested. Results show a significant (three orders of magnitude) reduction of transmitted energy, as measured in power spectral density (PSD), using the isolation materials. It is noted, however, that passive materials cannot prevent the transmission of very strong forces or absorb the total energy induced from structural resonances.

  17. Psychological interventions influence patients' attitudes and beliefs about their chronic pain.

    PubMed

    Vanhaudenhuyse, Audrey; Gillet, Aline; Malaise, Nicole; Salamun, Irène; Grosdent, Stéphanie; Maquet, Didier; Nyssen, Anne-Sophie; Faymonville, Marie-Elisabeth

    2018-04-01

    Patients' changing attitudes and beliefs about pain are considered as improvements in the treatment of chronic pain. Multidisciplinary approaches to pain allow modifications of coping strategies of patients, from passive to active. We investigate how two therapeutic treatments impact patients' attitudes and beliefs regarding pain, as measured with the Survey of Pain Attitudes (SOPA). We allocated 415 patients with chronic pain either to psychoeducation combined with physiotherapy, self-hypnosis combined with self-care learning, or to control groups. Pain intensity, global impression of change, and beliefs and attitudes regarding pain were assessed before and after treatment. Our main results showed a significant effect of psychoeducation/physiotherapy on control, harm, and medical cure SOPA subscales; and a significant effect of self-hypnosis/self-care on control, disability and medical cure subscales. Correlation results showed that pain perception was negatively associated with control, while positively associated with disability, and a belief that hurt signifies harm. Patients' impression of improvement was associated with greater control, lower disability, and lower belief that hurt signifies harm. The present study showed that self-hypnosis/self-care and psychoeducation/physiotherapy were associated with patients' evolution of coping strategies from passive to active, allowing them to reduce pain perception and improve their global impression of treatment effectiveness.

  18. Transcranial Doppler ultrasonographic evaluation of cerebral circulation during passive tilting in patients with Parkinson's disease.

    PubMed

    Mihci, Ebru; Dora, Babür; Balkan, Sevin

    2007-01-01

    To assess the effects of the tilt test on cerebral blood flow velocity (CBFV), blood pressure, and heart rate in patients with Parkinson's disease (PD) without symptomatic orthostatic dysautonomia. Thirty patients with idiopathic PD and 15 healthy controls were included. Mean middle cerebral artery blood flow velocity (CBFV) was recorded with transcranial Doppler sonography, while systolic (SBP), diastolic (DBP), and mean (MBP) blood pressure and heart rate were measured in the supine position and after passive tilting. There was no difference in resting SBP, DBP, or MBP between patients and controls. CBFV was lower at rest in patients than in controls and dropped significantly and similarly after tilting in both groups. SBP decreased in patients during the first 5 minutes of tilting (p < 0.05), whereas it increased progressively after the first minute in controls. In patients, DBP decreased slightly and MBP dropped during the first 2 minutes, then increased. Baseline heart rate was higher in patients than in controls (p < 0.05) and increased in both groups during tilting. Our results suggest that cardiovascular responses to tilting are delayed in PD patients and that subclinical autonomic dysfunction may be present even in the absence of symptomatic orthostatic dysautonomia. Copyright 2007 Wiley Periodicals, Inc.

  19. Energy-Efficient Next-Generation Passive Optical Networks Based on Sleep Mode and Heuristic Optimization

    NASA Astrophysics Data System (ADS)

    Zulai, Luis G. T.; Durand, Fábio R.; Abrão, Taufik

    2015-05-01

    In this article, an energy-efficiency mechanism for next-generation passive optical networks is investigated through heuristic particle swarm optimization. Ten-gigabit Ethernet-wavelength division multiplexing optical code division multiplexing-passive optical network next-generation passive optical networks are based on the use of a legacy 10-gigabit Ethernet-passive optical network with the advantage of using only an en/decoder pair of optical code division multiplexing technology, thus eliminating the en/decoder at each optical network unit. The proposed joint mechanism is based on the sleep-mode power-saving scheme for a 10-gigabit Ethernet-passive optical network, combined with a power control procedure aiming to adjust the transmitted power of the active optical network units while maximizing the overall energy-efficiency network. The particle swarm optimization based power control algorithm establishes the optimal transmitted power in each optical network unit according to the network pre-defined quality of service requirements. The objective is controlling the power consumption of the optical network unit according to the traffic demand by adjusting its transmitter power in an attempt to maximize the number of transmitted bits with minimum energy consumption, achieving maximal system energy efficiency. Numerical results have revealed that it is possible to save 75% of energy consumption with the proposed particle swarm optimization based sleep-mode energy-efficiency mechanism compared to 55% energy savings when just a sleeping-mode-based mechanism is deployed.

  20. Learned Helplessness at Fifty: Insights from Neuroscience

    PubMed Central

    Maier, Steven F.; Seligman, Martin E. P.

    2016-01-01

    Learned helplessness, the failure to escape shock induced by uncontrollable aversive events, was discovered half a century ago. Seligman and Maier (1967) theorized that animals learned that outcomes were independent of their responses—that nothing they did mattered – and that this learning undermined trying to escape. The mechanism of learned helplessness is now very well-charted biologically and the original theory got it backwards. Passivity in response to shock is not learned. It is the default, unlearned response to prolonged aversive events and it is mediated by the serotonergic activity of the dorsal raphe nucleus, which in turn inhibits escape. This passivity can be overcome by learning control, with the activity of the medial prefrontal cortex, which subserves the detection of control leading to the automatic inhibition of the dorsal raphe nucleus. So animals learn that they can control aversive events, but the passive failure to learn to escape is an unlearned reaction to prolonged aversive stimulation. In addition, alterations of the ventromedial prefrontal cortex-dorsal raphe pathway can come to subserve the expectation of control. We speculate that default passivity and the compensating detection and expectation of control may have substantial implications for how to treat depression. PMID:27337390

  1. Learned helplessness at fifty: Insights from neuroscience.

    PubMed

    Maier, Steven F; Seligman, Martin E P

    2016-07-01

    Learned helplessness, the failure to escape shock induced by uncontrollable aversive events, was discovered half a century ago. Seligman and Maier (1967) theorized that animals learned that outcomes were independent of their responses-that nothing they did mattered-and that this learning undermined trying to escape. The mechanism of learned helplessness is now very well-charted biologically, and the original theory got it backward. Passivity in response to shock is not learned. It is the default, unlearned response to prolonged aversive events and it is mediated by the serotonergic activity of the dorsal raphe nucleus, which in turn inhibits escape. This passivity can be overcome by learning control, with the activity of the medial prefrontal cortex, which subserves the detection of control leading to the automatic inhibition of the dorsal raphe nucleus. So animals learn that they can control aversive events, but the passive failure to learn to escape is an unlearned reaction to prolonged aversive stimulation. In addition, alterations of the ventromedial prefrontal cortex-dorsal raphe pathway can come to subserve the expectation of control. We speculate that default passivity and the compensating detection and expectation of control may have substantial implications for how to treat depression. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  2. Passive stability and actuation of micro aerial vehicles

    NASA Astrophysics Data System (ADS)

    Piccoli, Matthew

    Micro Aerial Vehicles (MAVs) have increased in popularity in recent years. The most common platform, the quadrotor, has surpassed other MAVs like traditional helicopters and ornithopters in popularity mainly due to their simplicity. Yet the quadrotor design is a century old and was intended to carry people. We set out to design a MAV that is designed specifically to be a MAV, i.e. a vehicle not intended to carry humans as a payload. With this constraint lifted the vehicle can continuously rotate, which would dizzy a human, can sustain larger forces, which would damage a human, or can take advantage of scaling properties, where it may not work at human scale. Furthermore, we aim for simplicity by removing vehicle controllers and reducing the number of actuators, such that the vehicle can be made cost effective, if not disposable. We begin by studying general equations of motion for hovering MAVs. We search for vehicle configurations that exhibit passive stability, allowing the MAV to operate without a controller or actuators to apply control, ideally a single actuator. The analysis suggests two distinct types of passively stabilized MAVs and we create test vehicles for both. With simple hovering achieved, we concentrate on controlled motion with an emphasis on doing so without adding actuators. We find we can attain three degree of freedom control using separation of time scales with our actuator via low frequency for control in the vertical direction and high frequency for control in the horizontal plane. We explore techniques for achieving high frequency actuator control, which also allow the compensation of motor defects, specifically cogging torque. We combine passive stability with the motion control into two vehicles, UNO and Piccolissimo. UNO, the Underactuated-propeller Naturally-stabilized One-motor vehicle, demonstrates the capabilities of simple vehicles by performing maneuvers like conventional quadrotors. Piccolissimo, Italian for very little, demonstrates the merits of passive stability and single actuator control by being the smallest, self-powered, controllable MAV.

  3. Acute response to hydrotherapy after a simulated game of rugby.

    PubMed

    Higgins, Trevor R; Cameron, Melainie L; Climstein, Mike

    2013-10-01

    Despite lacking clear scientific evidence, hydrotherapies (water treatments) are accepted techniques to help team sport athletes recover from the physical effects of games. The purpose of this study was to assess the comparative effectiveness of cold water immersions (CWIs) and hot-and-cold contrast baths on athletes' recovery after a simulated game of rugby union. Twenty-four experienced, well-trained, male rugby union players were divided into 3 groups to receive recovery interventions: CWI for 1 group, contrast baths for a second group, and passive recovery for a third (control) group. Pregame and postgame measurements included a countermovement jump (normalized as a ratio to body weight), a sit-and-stretch flexibility test (centimeters), thigh circumference (to detect swelling; centimeters), and participants' perception of delayed-onset muscular soreness (DOMS, 100-mm visual analog scale). Statistical analysis included analysis of variance, and the calculation of omnibus effect sizes for each group ((Equation is included in full-text article.)) and the magnitudes of change within and between groups (Cohen's d). The participants in the contrast bath group reported statistically significantly greater measures of DOMS than participants in the control group did at 1 hour postintervention (p = 0.05, control group: d = 1.80; contrast bath: d = 4.75), and than participants in the CWI group did at 48 hours postintervention (p = 0.02, CWI: d = 1.17; contrast bath: d = 1.97). These findings provide modest evidence that contrast baths are a less effective strategy for recovery from rugby union than are CWI or passive recovery. Specifically, 2 × 5-minute CWI is superior to both contrasts baths and passive recovery in alleviating DOMS after exercise-induced muscle damage. Our recommendation for rugby union players aiming to attenuate the effects of DOMS postgames is to take 2 × 5-minute CWIs baths immediately after the game.

  4. Impact of Elevated Core Body Temperature on Attention Networks.

    PubMed

    Liu, Kai; Jiang, Qingjun; Li, Li; Li, Bo; Yang, Zhen; Qian, Shaowen; Li, Min; Sun, Gang

    2015-12-01

    Cognitive function can be impaired after passive heat exposure and with an elevation in core body temperature (Tcore). This study examined the dynamic correlation among passive heat exposure, Tcore, and cognition. We gave the Attention Network Test of alerting, orienting, and executive control to five groups of five young men who were being exposed to a hyperthermic condition (50°C, 40% relative humidity) for 0, 10, 20, 30, or 40 minutes. We used the participants' reaction time, accuracy (correct responses), efficiency (accuracy÷reaction time), and Tcore to estimate optimal curve models for best fit of data. We could not estimate an appropriate curve model for either alerting or orienting with Tcore, change in Tcore, or duration of passive heat exposure. We estimated quadratic models for Tcore and duration (adjusted R=0.752), change in Tcore and duration (0.906), executive control score and duration (0.509), and efficiency of executive control and duration (0.293). We estimated linear models for executive control score and Tcore (0.479), efficiency of executive control and Tcore (0.261), executive control score and change in Tcore (0.279), and efficiency of executive control and change in Tcore (0.262). Different attentional abilities had different sensitivities to thermal stress. Executive control of attention deteriorated linearly with a rise in Tcore within the normal physiologic range, but deteriorated nonlinearly with longer passive heat exposure.

  5. South Philadelphia Passive Sampler and Sensor Study: Interim Report

    EPA Science Inventory

    Starting in June 2013, the United States Environmental Protection Agency (U.S. EPA) and the City of Philadelphia Air Measurements Services began collaborative research on the use of passive samplers (PSs) and stand-alone air measurement (SAM) systems to improve information on the...

  6. VOLATILE ORGANIC COMPOUNDS AS BREATH BIOMARKERS FOR ACTIVE AND PASSIVE SMOKING

    EPA Science Inventory

    Real-time breath measurement technology was used to investigate the suitability of some volatile organic compounds (VOCs) to serve as breath biomarkers for active and passive smoking and to measure actual exposures and resulting breath concentrations for persons exposed to toba...

  7. South Philadelphia Passive Sampler and Sensor Study - Interim Report

    EPA Science Inventory

    Starting in the June 2013, the U.S. EPA and the City of Philadelphia Air Measurements Services (AMS) began a collaborative research project to investigate how sensor-based, stand-alone air measurements (SAMs) and passive samplers (PSs) can help improve information on air pollutan...

  8. Performance Evaluation of Automated Passive Capillary Sampler for Estimating Water Drainage in the Vadose Zone

    USDA-ARS?s Scientific Manuscript database

    Passive capillary samplers (PCAPs) are widely used to monitor, measure and sample drainage water under saturated and unsaturated soil conditions in the vadose zone. The objective of this study was to evaluate the performance and accuracy of automated passive capillary sampler for estimating drainage...

  9. Using bioavailability to assess contaminated sediment risk: Passive sampling and Pore Water Remedial Guidelines (PWRGs)

    EPA Science Inventory

    Hosted by the Contaminated Sediment Forum, this half-day course will introduce the RPM to the use of passive samplers to assess bioavailability and in ecological risk assessment. Passive sampling devices (PSD) are a technology with growing acceptance for measuring porewater conce...

  10. Measurement of gaseous PAHs with an innovative passive sampler in community exposure studies

    EPA Science Inventory

    A sensitive, simple, and cost-effective passive sampling methodology was developed to quantify gaseous polycyclic aromatic hydrocarbons (PAHs) in personal, indoor and outdoor air. A Fan-Lioy passive PAH sampler (FL-PPS) is constructed from four 80 sections of 1 cm long SPB-5 GC c...

  11. Effect of temperature on the passivation behavior of steel rebar

    NASA Astrophysics Data System (ADS)

    Chen, Shan-meng; Cao, Bei; Wu, Yin-shun; Ma, Ke

    2014-05-01

    Steel rebar normally forms an oxide or rusty skin before it is embedded into concrete and the passivation properties of this skin will be heavily influenced by temperature. To study the effect of temperature on the passivation properties of steel rebar under different surface conditions, we conducted scanning electron microscopy (SEM) observations and electrochemical measurements, such as measurements of the free corrosion potential and polarization curves of HPB235 steel rebar. These measurements identified three kinds of surfaces: polished, oxide skin, and rusty skin. Our results show that the passivation properties of all the surface types decrease with the increase of temperature. Temperature has the greatest effect on the rusty-skin rebar and least effect on the polished steel rebar, because of cracks and crevices on the mill scale on the steel rebar's surface. The rusty-skin rebar exhibits the highest corrosion rate because crevice corrosion can accelerate the corrosion of the steel rebar, particularly at high temperature. The results also indicate that the threshold temperatures of passivation for the oxide-skin rebar and the rusty-skin rebar are 37°C and 20°C, respectively.

  12. Small is big: Interactive Trumps passive information in breaking information barriers and impacting behavioral antecedents

    DOE PAGES

    Beck, Ariane L.; Lakkaraju, Kiran; Rai, Varun; ...

    2017-01-18

    The wealth of information available on seemingly every topic creates a considerable challenge both for information providers trying to rise above the noise and discerning individuals trying to find relevant, trustworthy information. We approach this information problem by investigating how passive versus interactive information interventions can impact the antecedents of behavior change using the context of solar energy adoption, where persistent information gaps are known to reduce market potential. We use two experiments to investigate the impact of both passive and interactive approaches to information delivery on the antecedents (attitudes, subjective norms, and perceived behavioral control in the Theory ofmore » Planned Behavior) of intentions and behavior, as well as their effect on intentions and behavior directly. The passive information randomized control trial delivered via Amazon Mechanical Turk tests the effectiveness of delivering the same content in a single message versus multiple shorter messages. The interactive information delivery uses an online (mobile and PC) trivia-style gamification platform. Both experiments use the same content and are carried out over a two-week time period. Lastly, our findings suggest that interactive, gamified information has greater impact than passive information, and that shorter multiple messages of passive information are more effective than a single passive message.« less

  13. Small is big: Interactive Trumps passive information in breaking information barriers and impacting behavioral antecedents

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beck, Ariane L.; Lakkaraju, Kiran; Rai, Varun

    The wealth of information available on seemingly every topic creates a considerable challenge both for information providers trying to rise above the noise and discerning individuals trying to find relevant, trustworthy information. We approach this information problem by investigating how passive versus interactive information interventions can impact the antecedents of behavior change using the context of solar energy adoption, where persistent information gaps are known to reduce market potential. We use two experiments to investigate the impact of both passive and interactive approaches to information delivery on the antecedents (attitudes, subjective norms, and perceived behavioral control in the Theory ofmore » Planned Behavior) of intentions and behavior, as well as their effect on intentions and behavior directly. The passive information randomized control trial delivered via Amazon Mechanical Turk tests the effectiveness of delivering the same content in a single message versus multiple shorter messages. The interactive information delivery uses an online (mobile and PC) trivia-style gamification platform. Both experiments use the same content and are carried out over a two-week time period. Lastly, our findings suggest that interactive, gamified information has greater impact than passive information, and that shorter multiple messages of passive information are more effective than a single passive message.« less

  14. Small Is Big: Interactive Trumps Passive Information in Breaking Information Barriers and Impacting Behavioral Antecedents.

    PubMed

    Beck, Ariane L; Lakkaraju, Kiran; Rai, Varun

    2017-01-01

    The wealth of information available on seemingly every topic creates a considerable challenge both for information providers trying to rise above the noise and discerning individuals trying to find relevant, trustworthy information. We approach this information problem by investigating how passive versus interactive information interventions can impact the antecedents of behavior change using the context of solar energy adoption, where persistent information gaps are known to reduce market potential. We use two experiments to investigate the impact of both passive and interactive approaches to information delivery on the antecedents (attitudes, subjective norms, and perceived behavioral control in the Theory of Planned Behavior) of intentions and behavior, as well as their effect on intentions and behavior directly. The passive information randomized control trial delivered via Amazon Mechanical Turk tests the effectiveness of delivering the same content in a single message versus multiple shorter messages. The interactive information delivery uses an online (mobile and PC) trivia-style gamification platform. Both experiments use the same content and are carried out over a two-week time period. Our findings suggest that interactive, gamified information has greater impact than passive information, and that shorter multiple messages of passive information are more effective than a single passive message.

  15. Controlling under-actuated robot arms using a high speed dynamics process

    NASA Technical Reports Server (NTRS)

    Jain, Abhinandan (Inventor); Rodriguez, Guillermo (Inventor)

    1994-01-01

    The invention controls an under-actuated manipulator by first obtaining predetermined active joint accelerations of the active joints and the passive joint friction forces of the passive joints, then computing articulated body qualities for each of the joints from the current positions of the links, and finally computing from the articulated body qualities and from the active joint accelerations and the passive joint forces, active joint forces of the active joints. Ultimately, the invention transmits servo commands to the active joint forces thus computed to the respective ones of the joint servos. The computation of the active joint forces is accomplished using a recursive dynamics algorithm. In this computation, an inward recursion is first carried out for each link, beginning with the outermost link in order to compute the residual link force of each link from the active joint acceleration if the corresponding joint is active, or from the known passive joint force if the corresponding joint is passive. Then, an outward recursion is carried out for each link in which the active joint force is computed from the residual link force if the corresponding joint is active or the passive joint acceleration is computed from the residual link force if the corresponding joint is passive.

  16. Small Is Big: Interactive Trumps Passive Information in Breaking Information Barriers and Impacting Behavioral Antecedents

    PubMed Central

    2017-01-01

    The wealth of information available on seemingly every topic creates a considerable challenge both for information providers trying to rise above the noise and discerning individuals trying to find relevant, trustworthy information. We approach this information problem by investigating how passive versus interactive information interventions can impact the antecedents of behavior change using the context of solar energy adoption, where persistent information gaps are known to reduce market potential. We use two experiments to investigate the impact of both passive and interactive approaches to information delivery on the antecedents (attitudes, subjective norms, and perceived behavioral control in the Theory of Planned Behavior) of intentions and behavior, as well as their effect on intentions and behavior directly. The passive information randomized control trial delivered via Amazon Mechanical Turk tests the effectiveness of delivering the same content in a single message versus multiple shorter messages. The interactive information delivery uses an online (mobile and PC) trivia-style gamification platform. Both experiments use the same content and are carried out over a two-week time period. Our findings suggest that interactive, gamified information has greater impact than passive information, and that shorter multiple messages of passive information are more effective than a single passive message. PMID:28099478

  17. Parsing the Passive: Comparing Children with Specific Language Impairment to Sequential Bilingual Children

    ERIC Educational Resources Information Center

    Marinis, Theodoros; Saddy, Douglas

    2013-01-01

    Twenty-five monolingual (L1) children with specific language impairment (SLI), 32 sequential bilingual (L2) children, and 29 L1 controls completed the Test of Active & Passive Sentences-Revised (van der Lely 1996) and the Self-Paced Listening Task with Picture Verification for actives and passives (Marinis 2007). These revealed important…

  18. Virtual Passive Controller for Robot Systems Using Joint Torque Sensors

    NASA Technical Reports Server (NTRS)

    Aldridge, Hal A.; Juang, Jer-Nan

    1997-01-01

    This paper presents a control method based on virtual passive dynamic control that will stabilize a robot manipulator using joint torque sensors and a simple joint model. The method does not require joint position or velocity feedback for stabilization. The proposed control method is stable in the sense of Lyaponov. The control method was implemented on several joints of a laboratory robot. The controller showed good stability robustness to system parameter error and to the exclusion of nonlinear dynamic effects on the joints. The controller enhanced position tracking performance and, in the absence of position control, dissipated joint energy.

  19. Coping Styles, Well-Being and Self-Care Behaviors Among African Americans With Type 2 Diabetes

    PubMed Central

    Samuel-Hodge, Carmen D.; Watkins, Daphne C.; Rowell, Kyrel L.; Hooten, Elizabeth G.

    2009-01-01

    Purpose The purpose of this study was to describe how coping styles among African Americans with type 2 diabetes relate to diabetes appraisals, self-care behaviors, and health-related quality of life or well-being. Methods This cross-sectional analysis of baseline measures from 185 African Americans with type 2 diabetes enrolled in a church-based randomized controlled trial uses the theoretical framework of the transactional model of stress and coping to describe bivariate and multivariate associations among coping styles, psychosocial factors, self-care behaviors, and well-being, as measured by validated questionnaires. Results Among participants who were on average 59 years of age with 9 years of diagnosed diabetes, passive and emotive styles of coping were used most frequently, with older and less educated participants using more often passive forms of coping. Emotive styles of coping were significantly associated with greater perceived stress, problem areas in diabetes, and negative appraisals of diabetes control. Both passive and active styles of coping were associated with better diabetes self-efficacy and competence in bivariate analysis. In multivariate analysis, significant proportions of the variance in dietary behaviors and mental well-being outcomes (general and diabetes specific) were explained, with coping styles among the independent predictors. A positive role for church involvement in the psychological adaptation to living with diabetes was also observed. Conclusions In this sample of older African Americans with diabetes, coping styles were important factors in diabetes appraisals, self-care behaviors, and psychological outcomes. These findings suggest potential benefits in emphasizing cognitive and behavioral strategies to promote healthy coping outcomes in persons living with diabetes. PMID:18535323

  20. Effect of intermittent normobaric hypoxia on aerobic capacity and cognitive function in older people.

    PubMed

    Schega, Lutz; Peter, Beate; Brigadski, Tanja; Leßmann, Volkmar; Isermann, Berend; Hamacher, Dennis; Törpel, Alexander

    2016-11-01

    Physical exercise, especially aerobic training, improves physical performance and cognitive function of older people. Furthermore, it has been speculated that age-associated deteriorations in physical performance and cognitive function could be counteracted through exposures to passive intermittent normobaric hypoxia (IH). Thus, the present investigation aimed at investigating the effect of passive IH combined with subsequent aerobic training on hematological parameters and aerobic physical performance (V˙O 2max ) as well as peripheral levels of the neurotrophin brain-derived neurotrophic factor (BDNF) and cognitive function. Randomized controlled trial in a repeated measure design. 34 older participants were randomly assigned to an intervention group (IG) or control group (CG). While IG was supplied with passive IH for 90min, CG breathed ambient air. Subsequently, both groups underwent 30min of aerobic training three times per week for four consecutive weeks. Aerobic physical performance and cognitive function was tested with spiroergometry and the Stroop test. Blood samples were taken to measure hematological parameters and the peripheral serum BDNF-level. We found increases in the values of hematological parameters, the time to exhaustion in the load test and an augmented and sustainable improvement in cognitive function within the IG of the older people only. However, in both groups, the V˙O 2max and serum BDNF-level did not increase. Based on these results, hypoxic training seems to be beneficial to enhance hematological parameters, physical performance and cognitive function in older people. The current hypoxic-dose was not able to enhance the serum BDNF-level or V˙O 2max . Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  1. The corrosion behavior of technetium metal exposed to aqueous sulfate and chloride solutions

    DOE PAGES

    Kolman, David Gary; Goff, George Scott; Cisneros, Michael Ruben; ...

    2017-04-19

    Here, metal waste forms are being studied as possible disposal forms for technetium and other fission products from spent nuclear fuel. As an initial step in assessing the viability of waste forms, technetium corrosion and passivity behavior was assessed across a broad pH spectrum (pH –1 to pH 13). Measurements indicate that the open circuit potential falls into the region of Tc +7 stability, more noble than the region of presumed passivity. Potentiodynamic polarization tests indicate that the Tc samples are not passive. Both electrochemical results and visual inspection suggest the presence of a nonprotective film. The corrosion rate ismore » relatively independent of pH and low, as measured by linear polarization resistance. No evidence of passivity was observed in the Tc +4 region of the potential-pH diagram following in-situ abrasion, suggesting that Tc does not passivate, regardless of potential.« less

  2. The corrosion behavior of technetium metal exposed to aqueous sulfate and chloride solutions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kolman, David Gary; Goff, George Scott; Cisneros, Michael Ruben

    Here, metal waste forms are being studied as possible disposal forms for technetium and other fission products from spent nuclear fuel. As an initial step in assessing the viability of waste forms, technetium corrosion and passivity behavior was assessed across a broad pH spectrum (pH –1 to pH 13). Measurements indicate that the open circuit potential falls into the region of Tc +7 stability, more noble than the region of presumed passivity. Potentiodynamic polarization tests indicate that the Tc samples are not passive. Both electrochemical results and visual inspection suggest the presence of a nonprotective film. The corrosion rate ismore » relatively independent of pH and low, as measured by linear polarization resistance. No evidence of passivity was observed in the Tc +4 region of the potential-pH diagram following in-situ abrasion, suggesting that Tc does not passivate, regardless of potential.« less

  3. Space charge dosimeters for extremely low power measurements of radiation in shipping containers

    DOEpatents

    Britton, Jr., Charles L.; Buckner, Mark A [Oak Ridge, TN; Hanson, Gregory R [Clinton, TN; Bryan, William L [Knoxville, TN

    2011-05-03

    Methods and apparatus are described for space charge dosimeters for extremely low power measurements of radiation in shipping containers. A method includes insitu polling a suite of passive integrating ionizing radiation sensors including reading-out dosimetric data from a first passive integrating ionizing radiation sensor and a second passive integrating ionizing radiation sensor, where the first passive integrating ionizing radiation sensor and the second passive integrating ionizing radiation sensor remain situated where the dosimetric data was integrated while reading-out. Another method includes arranging a plurality of ionizing radiation sensors in a spatially dispersed array; determining a relative position of each of the plurality of ionizing radiation sensors to define a volume of interest; collecting ionizing radiation data from at least a subset of the plurality of ionizing radiation sensors; and triggering an alarm condition when a dose level of an ionizing radiation source is calculated to exceed a threshold.

  4. Space charge dosimeters for extremely low power measurements of radiation in shipping containers

    DOEpatents

    Britton, Jr; Charles, L [Alcoa, TN; Buckner, Mark A [Oak Ridge, TN; Hanson, Gregory R [Clinton, TN; Bryan, William L [Knoxville, TN

    2011-04-26

    Methods and apparatus are described for space charge dosimeters for extremely low power measurements of radiation in shipping containers. A method includes in situ polling a suite of passive integrating ionizing radiation sensors including reading-out dosimetric data from a first passive integrating ionizing radiation sensor and a second passive integrating ionizing radiation sensor, where the first passive integrating ionizing radiation sensor and the second passive integrating ionizing radiation sensor remain situated where the dosimetric data was integrated while reading-out. Another method includes arranging a plurality of ionizing radiation sensors in a spatially dispersed array; determining a relative position of each of the plurality of ionizing radiation sensors to define a volume of interest; collecting ionizing radiation data from at least a subset of the plurality of ionizing radiation sensors; and triggering an alarm condition when a dose level of an ionizing radiation source is calculated to exceed a threshold.

  5. Standing with electrical stimulation and splinting is no better than standing alone for management of ankle plantarflexion contractures in people with traumatic brain injury: a randomised trial.

    PubMed

    Leung, Joan; Harvey, Lisa A; Moseley, Anne M; Whiteside, Bhavini; Simpson, Melissa; Stroud, Katarina

    2014-12-01

    Is a combination of standing, electrical stimulation and splinting more effective than standing alone for the management of ankle contractures after severe brain injury? A multi-centre randomised trial with concealed allocation, assessor blinding and intention-to-treat analysis. Thirty-six adults with severe traumatic brain injury and ankle plantarflexion contractures. All participants underwent a 6-week program. The experimental group received tilt table standing, electrical stimulation and ankle splinting. The control group received tilt table standing alone. The primary outcome was passive ankle dorsiflexion with a 12Nm torque. Secondary outcomes included: passive dorsiflexion with lower torques (3, 5, 7 and 9Nm); spasticity; the walking item of the Functional Independence Measure; walking speed; global perceived effect of treatment; and perceived treatment credibility. OUTCOME MEASURES were taken at baseline (Week 0), end of intervention (Week 6), and follow-up (Week 10). The mean between-group differences (95% CI) for passive ankle dorsiflexion at Week 6 and Week 10 were -3 degrees (-8 to 2) and -1 degrees (-6 to 4), respectively, in favour of the control group. There was a small mean reduction of 1 point in spasticity at Week 6 (95% CI 0.1 to 1.8) in favour of the experimental group, but this effect disappeared at Week 10. There were no differences for other secondary outcome measures except the physiotherapists' perceived treatment credibility. Tilt table standing with electrical stimulation and splinting is not better than tilt table standing alone for the management of ankle contractures after severe brain injury. ACTRN12608000637347. [Leung J, Harvey LA, Moseley AM, Whiteside B, Simpson M, Stroud K (2014) Standing with electrical stimulation and splinting is no better than standing alone for management of ankle plantarflexion contractures in people with traumatic brain injury: a randomised trial.Journal of Physiotherapy60: 201-208]. Copyright © 2014 Australian Physiotherapy Association. Published by Elsevier B.V. All rights reserved.

  6. Intracochlear Scala Media Pressure Measurement: Implications for Models of Cochlear Mechanics.

    PubMed

    Kale, Sushrut S; Olson, Elizabeth S

    2015-12-15

    Models of the active cochlea build upon the underlying passive mechanics. Passive cochlear mechanics is based on physical and geometrical properties of the cochlea and the fluid-tissue interaction between the cochlear partition and the surrounding fluid. Although the fluid-tissue interaction between the basilar membrane and the fluid in scala tympani (ST) has been explored in both active and passive cochleae, there was no experimental data on the fluid-tissue interaction on the scala media (SM) side of the partition. To this aim, we measured sound-evoked intracochlear pressure in SM close to the partition using micropressure sensors. All the SM pressure data are from passive cochleae, likely because the SM cochleostomy led to loss of endocochlear potential. Thus, these experiments are studies of passive cochlear mechanics. SM pressure close to the tissue showed a pattern of peaks and notches, which could be explained as an interaction between fast and slow (i.e., traveling wave) pressure modes. In several animals SM and ST pressure were measured in the same cochlea. Similar to previous studies, ST-pressure was dominated by a slow, traveling wave mode at stimulus frequencies in the vicinity of the best frequency of the measurement location, and by a fast mode above best frequency. Antisymmetric pressure between SM and ST supported the classic single-partition cochlear models, or a dual-partition model with tight coupling between partitions. From the SM and ST pressure we calculated slow and fast modes, and from active ST pressure we extrapolated the passive findings to the active case. The passive slow mode estimated from SM and ST data was low-pass in nature, as predicted by cochlear models. Copyright © 2015 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  7. Comprehensive neuromechanical assessment in stroke patients: reliability and responsiveness of a protocol to measure neural and non-neural wrist properties.

    PubMed

    van der Krogt, Hanneke; Klomp, Asbjørn; de Groot, Jurriaan H; de Vlugt, Erwin; van der Helm, Frans Ct; Meskers, Carel Gm; Arendzen, J Hans

    2015-03-13

    Understanding movement disorder after stroke and providing targeted treatment for post stroke patients requires valid and reliable identification of biomechanical (passive) and neural (active and reflexive) contributors. Aim of this study was to assess test-retest reliability of passive, active and reflexive parameters and to determine clinical responsiveness in a cohort of stroke patients with upper extremity impairments and healthy volunteers. Thirty-two community-residing chronic stroke patients with an impairment of an upper limb and fourteen healthy volunteers were assessed with a comprehensive neuromechanical assessment protocol consisting of active and passive tasks and different stretch reflex-eliciting measuring velocities, using a haptic manipulator and surface electromyography of wrist flexor and extensor muscles (Netherlands Trial Registry number NTR1424). Intraclass correlation coefficients (ICC) and Standard Error of Measurement were calculated to establish relative and absolute test-retest reliability of passive, active and reflexive parameters. Clinical responsiveness was tested with Kruskal Wallis test for differences between groups. ICC of passive parameters were fair to excellent (0.45 to 0.91). ICC of active parameters were excellent (0.88-0.99). ICC of reflexive parameters were fair to good (0.50-0.74). Only the reflexive loop time of the extensor muscles performed poor (ICC 0.18). Significant differences between chronic stroke patients and healthy volunteers were found in ten out of fourteen parameters. Passive, active and reflexive parameters can be assessed with high reliability in post-stroke patients. Parameters were responsive to clinical status. The next step is longitudinal measurement of passive, active and reflexive parameters to establish their predictive value for functional outcome after stroke.

  8. Intracochlear Scala Media Pressure Measurement: Implications for Models of Cochlear Mechanics

    PubMed Central

    Kale, Sushrut S.; Olson, Elizabeth S.

    2015-01-01

    Models of the active cochlea build upon the underlying passive mechanics. Passive cochlear mechanics is based on physical and geometrical properties of the cochlea and the fluid-tissue interaction between the cochlear partition and the surrounding fluid. Although the fluid-tissue interaction between the basilar membrane and the fluid in scala tympani (ST) has been explored in both active and passive cochleae, there was no experimental data on the fluid-tissue interaction on the scala media (SM) side of the partition. To this aim, we measured sound-evoked intracochlear pressure in SM close to the partition using micropressure sensors. All the SM pressure data are from passive cochleae, likely because the SM cochleostomy led to loss of endocochlear potential. Thus, these experiments are studies of passive cochlear mechanics. SM pressure close to the tissue showed a pattern of peaks and notches, which could be explained as an interaction between fast and slow (i.e., traveling wave) pressure modes. In several animals SM and ST pressure were measured in the same cochlea. Similar to previous studies, ST-pressure was dominated by a slow, traveling wave mode at stimulus frequencies in the vicinity of the best frequency of the measurement location, and by a fast mode above best frequency. Antisymmetric pressure between SM and ST supported the classic single-partition cochlear models, or a dual-partition model with tight coupling between partitions. From the SM and ST pressure we calculated slow and fast modes, and from active ST pressure we extrapolated the passive findings to the active case. The passive slow mode estimated from SM and ST data was low-pass in nature, as predicted by cochlear models. PMID:26682824

  9. Strength training alone, exercise therapy alone, and exercise therapy with passive manual mobilisation each reduce pain and disability in people with knee osteoarthritis: a systematic review.

    PubMed

    Jansen, Mariette J; Viechtbauer, Wolfgang; Lenssen, Antoine F; Hendriks, Erik J M; de Bie, Rob A

    2011-01-01

    What are the effects of strength training alone, exercise therapy alone, and exercise with additional passive manual mobilisation on pain and function in people with knee osteoarthritis compared to control? What are the effects of these interventions relative to each other? A meta-analysis of randomised controlled trials. Adults with osteoarthritis of the knee. INTERVENTION TYPES: Strength training alone, exercise therapy alone (combination of strength training with active range of motion exercises and aerobic activity), or exercise with additional passive manual mobilisation, versus any non-exercise control. Comparisons between the three interventions were also sought. The primary outcome measures were pain and physical function. 12 trials compared one of the interventions against control. The effect size on pain was 0.38 (95% CI 0.23 to 0.54) for strength training, 0.34 (95% CI 0.19 to 0.49) for exercise, and 0.69 (95% CI 0.42 to 0.96) for exercise plus manual mobilisation. Each intervention also improved physical function significantly. No randomised comparisons of the three interventions were identified. However, meta-regression indicated that exercise plus manual mobilisations improved pain significantly more than exercise alone (p = 0.03). The remaining comparisons between the three interventions for pain and physical function were not significant. Exercise therapy plus manual mobilisation showed a moderate effect size on pain compared to the small effect sizes for strength training or exercise therapy alone. To achieve better pain relief in patients with knee osteoarthritis physiotherapists or manual therapists might consider adding manual mobilisation to optimise supervised active exercise programs. Copyright © 2011 Australian Physiotherapy Association. Published by .. All rights reserved.

  10. The effect of uncontrolled moment and short-term, repeated passive stretching on maximum ankle joint dorsiflexion angle.

    PubMed

    Gatt, Alfred; Chockalingam, Nachiappan

    2012-06-01

    Trials investigating ankle joint measurement normally apply a known moment. Maximum ankle angle is affected by foot posture and stretching characteristics of the calf muscles. To investigate whether consistent maximum ankle angles could be achieved without applying a constant moment to all subjects, and whether short, repetitive stretching of the calf muscle tendon unit would produce a difference in the maximum ankle angle. Passive dorsiflexion in 14 healthy participants was captured using an optoelectronic motion analysis system, with the foot placed in 3 postures. The maximum ankle angles for both the neutral and supinated positions did not differ significantly. In general, the majority of subjects (92.8%) showed no increase in the maximum ankle dorsiflexion angle following repetitive brief passive stretching. Only one subject exhibited a significant increase in maximum ankle angle at the neutral position. Since the range of motion of the ankle joint is clearly determined by other physical factors, the maximum ankle dorsiflexion angle can be assessed at both neutral and supinated positions without moment being controlled. Copyright © 2011 Elsevier Ltd. All rights reserved.

  11. [Passive tactile stimulation and its clinical and neurophysiological repercussions (P300) in blind children with symptoms of attention deficit disorder].

    PubMed

    Serrano-Marugán, Isabel; Herrera, Begoña; Romero, Sara; Nogales, Ramón; Poch-Broto, Joaquín; Quintero, Javier; Ortiz, Tomás

    2014-02-24

    Tactile stimulation is key for the posterior brain re-organization activity and attention processes, however the impact of tactile stimulation on attention deficit disorder (ADD) in blind children remains unexplored. We carried out a study with children having or not ADD (four per group). The subjects have been exposed during six months to tactile stimulation protocol consisting in two daily sessions (morning and afternoon sessions) of 30 minutes each. We have measured the ability to detect an infrequent tactile stimulus, reaction time, latency of P300, sources of brain activity, and ADD clinical symptoms, before and after tactile training. Passive tactile stimulation significantly improves ADD clinical symptoms, particularly attention, behavior and self-control of involuntary movements and tics. In addition, tactile stimulation changes the pattern of brain activity in ADD blind children inducing activity in frontal and occipital areas, which could be associated to a compensation of the attention deficit. Passive tactile stimulation training may improve ADD clinical symptoms and can reorganize the pattern of brain activity in blind ADD children.

  12. TV exposure associated with sleep disturbances in 5- to 6-year-old children.

    PubMed

    Paavonen, E Juulia; Pennonen, Marjo; Roine, Mira; Valkonen, Satu; Lahikainen, Anja Riitta

    2006-06-01

    The aim of this study was to investigate the effects of various forms of TV exposure on the quality of children's sleep. In this randomized population-based survey questionnaires concerning TV viewing, sleep disturbances, and psychiatric symptoms were administered to 321 parents of children aged 5-6 years. Sleep disturbance scores were the main outcome measures. Active TV viewing and passive TV exposure were related to sleeping difficulties, especially sleep-wake transition disorders and overall sleep disturbances. Particularly, passive TV exposure and viewing adult-targeted TV programs were strongly related to sleep disturbances. The association remained significant when socioeconomic status, family income, family conflicts, the father's work schedule, and the child's psychiatric symptoms were controlled statistically. The adjusted odds ratios were 2.91 (95% CI 1.03-8.17) and 3.01 (95% CI 1.13-8.05), respectively. TV viewing and particularly passive TV exposure and viewing adult-targeted programs significantly increase the risk of sleeping difficulties. The results suggest that health-care professionals should be aware of the association between TV exposure and sleep disturbances.

  13. A simple linear model for estimating ozone AOT40 at forest sites from raw passive sampling data.

    PubMed

    Ferretti, Marco; Cristofolini, Fabiana; Cristofori, Antonella; Gerosa, Giacomo; Gottardini, Elena

    2012-08-01

    A rapid, empirical method is described for estimating weekly AOT40 from ozone concentrations measured with passive samplers at forest sites. The method is based on linear regression and was developed after three years of measurements in Trentino (northern Italy). It was tested against an independent set of data from passive sampler sites across Italy. It provides good weekly estimates compared with those measured by conventional monitors (0.85 ≤R(2)≤ 0.970; 97 ≤ RMSE ≤ 302). Estimates obtained using passive sampling at forest sites are comparable to those obtained by another estimation method based on modelling hourly concentrations (R(2) = 0.94; 131 ≤ RMSE ≤ 351). Regression coefficients of passive sampling are similar to those obtained with conventional monitors at forest sites. Testing against an independent dataset generated by passive sampling provided similar results (0.86 ≤R(2)≤ 0.99; 65 ≤ RMSE ≤ 478). Errors tend to accumulate when weekly AOT40 estimates are summed to obtain the total AOT40 over the May-July period, and the median deviation between the two estimation methods based on passive sampling is 11%. The method proposed does not require any assumptions, complex calculation or modelling technique, and can be useful when other estimation methods are not feasible, either in principle or in practice. However, the method is not useful when estimates of hourly concentrations are of interest.

  14. Structural Damage Detection Using Virtual Passive Controllers

    NASA Technical Reports Server (NTRS)

    Lew, Jiann-Shiun; Juang, Jer-Nan

    2001-01-01

    This paper presents novel approaches for structural damage detection which uses the virtual passive controllers attached to structures, where passive controllers are energy dissipative devices and thus guarantee the closed-loop stability. The use of the identified parameters of various closed-loop systems can solve the problem that reliable identified parameters, such as natural frequencies of the open-loop system may not provide enough information for damage detection. Only a small number of sensors are required for the proposed approaches. The identified natural frequencies, which are generally much less sensitive to noise and more reliable than the identified natural frequencies, are used for damage detection. Two damage detection techniques are presented. One technique is based on the structures with direct output feedback controllers while the other technique uses the second-order dynamic feedback controllers. A least-squares technique, which is based on the sensitivity of natural frequencies to damage variables, is used for accurately identifying the damage variables.

  15. Spent fuel measurements. passive neutron albedo reactivity (PNAR) and photon signatures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eigenbrodt, Julia; Menlove, Howard Olsen

    2016-03-29

    The International Atomic Energy Agency’s (IAEA) safeguards technical objective is the timely detection of a diversion of a significant quantity of nuclear material from peaceful activities to the manufacture of nuclear weapons or of other nuclear explosive devices or for purposes unknown, and deterrence of such diversion by the risk of early detection. An important IAEA task towards meeting this objective is the ability to accurately and reliably measure spent nuclear fuel (SNF) to verify reactor operating parameters and verify that the fuel has not been removed from reactors or SNF storage facilities. This dissertation analyzes a method to improvemore » the state-of-the-art of nuclear material safeguards measurements using two combined measurement techniques: passive neutron albedo reactivity (PNAR) and passive spectral photon measurements.« less

  16. Passive Seismic for Hydrocarbon Indicator : Between Expectation and Reality

    NASA Astrophysics Data System (ADS)

    Pandito, Riky H. B.

    2018-03-01

    In between 5 – 10 years, in our country, passive seismic method became more popular to finding hydrocarbon. Low price, nondestructive acquisition and easy to mobilization is the best reason for choose the method. But in the other part, some people are pessimistically to deal with the result. Instrument specification, data condition and processing methods is several points which influence characteristic and interpretation passive seismic result. In 2010 one prospect in East Java Basin has been measurement constist of 112 objective points and several calibration points. Data measurement results indicate a positive response. Furthermore, in 2013 exploration drliing conducted on the prospect. Drill steam test showes 22 MMCFD in objective zone, upper – late oligocene. In 2015, remeasurement taken in objective area and show consistent responses with previous measurement. Passive seismic is unique method, sometimes will have difference results on dry, gas and oil area, in field production and also temporary suspend area with hidrocarbon content.

  17. Porcelain enamel passive thermal control coatings

    NASA Technical Reports Server (NTRS)

    Leggett, H.; King, H. M.

    1978-01-01

    This paper discusses the development and evaluation of a highly adherent, low solar absorptance, porcelain enamel thermal control coating applied to 6061 and 1100 aluminum for space vehicle use. The coating consists of a low index of refraction, transparent host frit and a high volume fraction of titania as rutile, crystallized in-situ, as the scattering medium. Solar absorptance is 0.21 at a coating thickness of 0.013 cm. Hemispherical emittance is 0.88. The change in solar absorptance is 0.03, as measured in-situ, after an exposure of 1000 equivalent sun hours in vacuum.

  18. Role of optical computers in aeronautical control applications

    NASA Technical Reports Server (NTRS)

    Baumbick, R. J.

    1981-01-01

    The role that optical computers play in aircraft control is determined. The optical computer has the potential high speed capability required, especially for matrix/matrix operations. The optical computer also has the potential for handling nonlinear simulations in real time. They are also more compatible with fiber optic signal transmission. Optics also permit the use of passive sensors to measure process variables. No electrical energy need be supplied to the sensor. Complex interfacing between optical sensors and the optical computer is avoided if the optical sensor outputs can be directly processed by the optical computer.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Jinyuan

    A digitization scheme of sub-microampere current using a commercial comparator with adjustable hysteresis and FPGA-based Wave Union TDC has been tested. The comparator plus a few passive components forms a current controlled oscillator and the input current is sent into the hysteresis control pin. The input current is converted into the transition times of the oscillations, which are digitized with a Wave Union TDC in FPGA and the variation of the transition times reflects the variation of the input current. Preliminary tests show that input charges < 25 fC can be measured at > 50 M samples/s without a preamplifier.

  20. Effect of radio-frequency electromagnetic radiations (RF-EMR) on passive avoidance behaviour and hippocampal morphology in Wistar rats.

    PubMed

    Narayanan, Sareesh Naduvil; Kumar, Raju Suresh; Potu, Bhagath Kumar; Nayak, Satheesha; Bhat, P Gopalakrishna; Mailankot, Maneesh

    2010-05-01

    The interaction of mobile phone radio-frequency electromagnetic radiation (RF-EMR) with the brain is a serious concern of our society. We evaluated the effect of RF-EMR from mobile phones on passive avoidance behaviour and hippocampal morphology in rats. Healthy male albino Wistar rats were exposed to RF-EMR by giving 50 missed calls (within 1 hour) per day for 4 weeks, keeping a GSM (0.9 GHz/1.8 GHz) mobile phone in vibratory mode (no ring tone) in the cage. After the experimental period, passive avoidance behaviour and hippocampal morphology were studied. Passive avoidance behaviour was significantly affected in mobile phone RF-EMR-exposed rats demonstrated as shorter entrance latency to the dark compartment when compared to the control rats. Marked morphological changes were also observed in the CA(3) region of the hippocampus of the mobile phone-exposed rats in comparison to the control rats. Mobile phone RF-EMR exposure significantly altered the passive avoidance behaviour and hippocampal morphology in rats.

  1. Understanding the rates of nonpolar organic chemical accumulation into passive samplers deployed in the environment: Guidance for passive sampler deployments.

    PubMed

    Apell, Jennifer N; Tcaciuc, A Patricia; Gschwend, Philip M

    2016-07-01

    Polymeric passive samplers have become a common method for estimating freely dissolved concentrations in environmental media. However, this approach has not yet been adopted by investigators conducting remedial investigations of contaminated environmental sites. Successful adoption of this sampling methodology relies on an understanding of how passive samplers accumulate chemical mass as well as developing guidance for the design and deployment of passive samplers. Herein, we outline the development of a simple mathematical relationship of the environmental, polymer, and chemical properties that control the uptake rate. This relationship, called a timescale, is then used to illustrate how each property controls the rate of equilibration in samplers deployed in the water or in the sediment. Guidance is also given on how to use the timescales to select an appropriate polymer, deployment time, and suite of performance reference compounds. Integr Environ Assess Manag 2016;12:486-492. © 2015 SETAC. © 2015 SETAC.

  2. Actuator with built-in viscous damping for isolation and structural control

    NASA Astrophysics Data System (ADS)

    Hyde, T. Tupper; Anderson, Eric H.

    1994-05-01

    This paper describes the development and experimental application of an actuator with built-in viscous damping. An existing passive damper was modified for use as a novel actuation device for isolation and structural control. The device functions by using the same fluid for viscous damping and as a hydraulic lever for a voice coil actuator. Applications for such an actuator include structural control and active isolation. Lumped parameter models capturing structural and fluid effects are presented. Component tests of free stroke, blocked force, and passive complex stiffness are used to update the assumed model parameters. The structural damping effectiveness of the new actuator is shown to be that of a regular D-strut passively and that of a piezoelectric strut with load cell feedback actively in a complex testbed structure. Open and closed loop results are presented for a force isolation application showing an 8 dB passive and 20 dB active improvement over an undamped mount. An optimized design for a future experimental testbed is developed.

  3. Separating Active and Passive Influences on Stomatal Control of Transpiration[OPEN

    PubMed Central

    McAdam, Scott A.M.; Brodribb, Timothy J.

    2014-01-01

    Motivated by studies suggesting that the stomata of ferns and lycophytes do not conform to the standard active abscisic acid (ABA) -mediated stomatal control model, we examined stomatal behavior in a conifer species (Metasequoia glyptostroboides) that is phylogenetically midway between the fern and angiosperm clades. Similar to ferns, daytime stomatal closure in response to moderate water stress seemed to be a passive hydraulic process in M. glyptostroboides immediately alleviated by rehydrating excised shoots. Only after prolonged exposure to more extreme water stress did active ABA-mediated stomatal closure become important, because foliar ABA production was triggered after leaf turgor loss. The influence of foliar ABA on stomatal conductance and stomatal aperture was highly predictable and additive with the passive hydraulic influence. M. glyptostroboides thus occupies a stomatal behavior type intermediate between the passively controlled ferns and the characteristic ABA-dependent stomatal closure described in angiosperm herbs. These results highlight the importance of considering phylogeny as a major determinant of stomatal behavior. PMID:24488969

  4. Separating active and passive influences on stomatal control of transpiration.

    PubMed

    McAdam, Scott A M; Brodribb, Timothy J

    2014-04-01

    Motivated by studies suggesting that the stomata of ferns and lycophytes do not conform to the standard active abscisic acid (ABA) -mediated stomatal control model, we examined stomatal behavior in a conifer species (Metasequoia glyptostroboides) that is phylogenetically midway between the fern and angiosperm clades. Similar to ferns, daytime stomatal closure in response to moderate water stress seemed to be a passive hydraulic process in M. glyptostroboides immediately alleviated by rehydrating excised shoots. Only after prolonged exposure to more extreme water stress did active ABA-mediated stomatal closure become important, because foliar ABA production was triggered after leaf turgor loss. The influence of foliar ABA on stomatal conductance and stomatal aperture was highly predictable and additive with the passive hydraulic influence. M. glyptostroboides thus occupies a stomatal behavior type intermediate between the passively controlled ferns and the characteristic ABA-dependent stomatal closure described in angiosperm herbs. These results highlight the importance of considering phylogeny as a major determinant of stomatal behavior.

  5. Measuring freely dissolved water concentrations of PCBs using LDPE passive samplers and performance reference compounds (PRCs)

    EPA Science Inventory

    Low-Density polyethylene (LDPE) sheets are often used as passive samplers for aquatic environmental monitoring to measure the dissolved concentrations of hydrophobic organic contaminants (HOCs). These concentrations are then used to evaluate the potential for ecological and human...

  6. Experimental Methodology for Determining Turbomachinery Blade Damping Using Magnetic Bearing Excitation and Non-Contacting Optical Measurements

    NASA Technical Reports Server (NTRS)

    Provenza, Andrew J.; Duffy, Kirsten P.

    2010-01-01

    Experiments to determine the effects of turbomachinery fan blade damping concepts such as passively shunted piezoelectric materials on blade response are ongoing at the NASA Glenn Research Center. A vertical rotor is suspended and excited with active magnetic bearings (AMBs) usually in a vacuum chamber to eliminate aerodynamic forces. Electromagnetic rotor excitation is superimposed onto rotor PD-controlled support and can be fixed to either a stationary or rotating frame of reference. The rotor speed is controlled with an air turbine system. Blade vibrations are measured using optical probes as part of a Non-Contacting Stress Measurement System (NSMS). Damping is calculated from these measurements. It can be difficult to get accurate damping measurements using this experimental setup and some of the details of how to obtain quality results are seemingly nontrivial. The intent of this paper is to present those details.

  7. Microbial communities in methane seep sediments along US Atlantic Margin are structured by organic matter and seepage dynamics

    NASA Astrophysics Data System (ADS)

    Graw, M. F.; Pohlman, J.; Treude, T.; Ruppel, C. D.; Colwell, F. S.

    2016-12-01

    Methane seeps are dynamic environments on continental margins where subsurface methane reaches the ocean. Microbial communities play a critical role in carbon cycling within seep sediments via organic carbon degradation, methane production, and anaerobic oxidation of methane (AOM), which consumes 20-80% of methane in seep sediments. However, biogeochemical controls on microbial community structure at seeps on a margin-wide scale remain unclear. The passive US Atlantic Margin (USAM) has been identified as a region of active methane seepage. Passive margin seeps have traditionally been understudied relative to seeps on active margins. Passive margins exhibit large cross-margin variability in organic carbon deposition and are anticipated to have divergent seep dynamics from active margins. Thus, the USAM offers a unique opportunity to investigate controls on microbial communities in seep sediments. We undertook analysis of microbial communities inhabiting seep sediments at 6 biogeochemically distinct sites along the USAM. Microbiological samples were co-located with measurements of sediment geochemistry and AOM and sulfate reduction rates. Illumina sequencing of the 16S rRNA gene, using both universal (83 samples) and archaeal-specific (64 samples) primers, and the mcrA gene (18 samples) identified 44 bacterial phyla and 7 archaeal phyla. Seeps in canyons and on open slope, likely representing high and low organic content sediments, hosted distinct communities; the former was dominated by ammonia-oxidizing Marine Group I Thaumarchaeota and the latter by mixotrophic Hadesarchaeota. Seep stability also impacted microbial community structure, and in particular the establishment of an AOM community rather than a Bathyarchaeota-dominated community. These findings contribute to understanding how microbial communities are structured within methane seep sediments and pave the way for investigating broad differences in carbon cycling between seeps on passive and active margins.

  8. The effect of postoperative passive motion on rotator cuff healing in a rat model.

    PubMed

    Peltz, Cathryn D; Dourte, Leann M; Kuntz, Andrew F; Sarver, Joseph J; Kim, Soung-Yon; Williams, Gerald R; Soslowsky, Louis J

    2009-10-01

    Surgical repairs of torn rotator cuff tendons frequently fail. Immobilization has been shown to improve tissue mechanical properties in an animal model of rotator cuff repair, and passive motion has been shown to improve joint mechanics in animal models of flexor tendon repair. Our objective was to determine if daily passive motion would improve joint mechanics in comparison with continuous immobilization in a rat rotator cuff repair model. We hypothesized that daily passive motion would result in improved passive shoulder joint mechanics in comparison with continuous immobilization initially and that there would be no differences in passive joint mechanics or insertion site mechanical properties after four weeks of remobilization. A supraspinatus injury was created and was surgically repaired in sixty-five Sprague-Dawley rats. Rats were separated into three postoperative groups (continuous immobilization, passive motion protocol 1, and passive motion protocol 2) for two weeks before all underwent a remobilization protocol for four weeks. Serial measurements of passive shoulder mechanics (internal and external range of motion and joint stiffness) were made before surgery and at two and six weeks after surgery. After the animals were killed, collagen organization and mechanical properties of the tendon-to-bone insertion site were determined. Total range of motion for both passive motion groups (49% and 45% of the pre-injury values) was less than that for the continuous immobilization group (59% of the pre-injury value) at two weeks and remained significantly less following four weeks of remobilization exercise. Joint stiffness at two weeks was increased for both passive motion groups in comparison with the continuous immobilization group. At both two and six weeks after repair, internal range of motion was significantly decreased whereas external range of motion was not. There were no differences between the groups in terms of collagen organization or mechanical properties. In this model, immediate postoperative passive motion was found to be detrimental to passive shoulder mechanics. We speculate that passive motion results in increased scar formation in the subacromial space, thereby resulting in decreased range of motion and increased joint stiffness. Passive motion had no effect on collagen organization or tendon mechanical properties measured six weeks after surgery.

  9. DFL, Canada's Space AIT Facilities - Current and Planned Capabilities

    NASA Astrophysics Data System (ADS)

    Singhal, R.; Mishra, S.; Choueiry, E.; Dumoulin, J.; Ahmed, S.

    2004-08-01

    The David Florida Laboratory (DFL) of the Canadian Space Agency is the Canadian national ISO 9001:2000 registered facility for the assembly, integration, and (environmental) testing of space hardware. This paper briefly describes the three main qualification facilities: Structural Qualification Facilities (SQF); Radio Frequency Qualification Facilities (RFQF); and Thermal Qualification Facilities (TQF). The paper also describes the planned/new upgrades/improvements to the DFL's existing capabilities. These include: cylindrical near-field antenna measurement system, current capabilities in multi-frequency multi-band passive intermodulation (PIM) measurement; combined thermal/vibration test facility, improvement in efficiency and performance of the photogrammetry capability, acquisition of an additional mass properties measurement system for small and micro-satellites; combined control and data acquisition system for all existing thermal vacuum facilities, plus a new automatic thermal control system and hypobaric chamber.

  10. Electrophysiological Correlates of the Threshold to Detection of Passive Motion: An Investigation in Professional Volleyball Athletes with and without Atrophy of the Infraspinatus Muscle

    PubMed Central

    Salles, José Inácio; Cossich, Victor Rodrigues Amaral; Amaral, Marcus Vinicius; Monteiro, Martim T.; Cagy, Maurício; Motta, Geraldo; Velasques, Bruna; Piedade, Roberto; Ribeiro, Pedro

    2013-01-01

    The goal of the present study is to compare the electrophysiological correlates of the threshold to detection of passive motion (TTDPM) among three groups: healthy individuals (control group), professional volleyball athletes with atrophy of the infraspinatus muscle on the dominant side, and athletes with no shoulder pathologies. More specifically, the study aims at assessing the effects of infraspinatus muscle atrophy on the cortical representation of the TTDPM. A proprioception testing device (PTD) was used to measure the TTDPM. The device passively moved the shoulder and participants were instructed to respond as soon as movement was detected (TTDPM) by pressing a button switch. Response latency was established as the delay between the stimulus (movement) and the response (button press). Electroencephalographic (EEG) and electromyographic (EMG) activities were recorded simultaneously. An analysis of variance (ANOVA) and subsequent post hoc tests indicated a significant difference in latency between the group of athletes without the atrophy when compared both to the group of athletes with the atrophy and to the control group. Furthermore, distinct patterns of cortical activity were observed in the three experimental groups. The results suggest that systematically trained motor abilities, as well as the atrophy of the infraspinatus muscle, change the cortical representation of the different stages of proprioceptive information processing and, ultimately, the cortical representation of the TTDPM. PMID:23484136

  11. Reversing flow causes passive shark scale actuation in a separating turbulent boundary layer

    NASA Astrophysics Data System (ADS)

    Lang, Amy; Gemmell, Bradford; Motta, Phil; Habegger, Laura; Du Clos, Kevin; Devey, Sean; Stanley, Caleb; Santos, Leo

    2017-11-01

    Control of flow separation by shortfin mako skin in experiments has been demonstrated, but the mechanism is still poorly understood yet must be to some extent Re independent. The hypothesized mechanisms inherent in the shark skin for controlling flow separation are: (1) the scales, which are capable of being bristled only by reversing flow, inhibit flow reversal events from further development into larger-scale separation and (2) the cavities formed when scales bristle induces mixing of high momentum flow towards the wall thus energizing the flow close to the surface. Two studies were carried out to measure passive scale actuation caused by reversing flow. A small flow channel induced an unsteady, wake flow over the scales prompting reversing flow events and scale actuation. To resolve the flow and scale movements simultaneously we used specialized optics at high magnification (1 mm field of view) at 50,000 fps. In another study, 3D printed models of shark scales, or microflaps (bristling capability up to 50 degrees), were set into a flat plate. Using a tripped, turbulent boundary layer grown over the long flat plate and a localized adverse pressure gradient, a separation bubble was generated within which the microflaps were placed. Passive flow actuation of both shark scales and microflaps by reversing flow was observed. Funding from Army Research Office and NSF REU site Grant.

  12. Calibrated Passive Sampling--Multi-plot Field Measurements of NH3 Emissions with a Combination of Dynamic Tube Method and Passive Samplers.

    PubMed

    Pacholski, Andreas

    2016-03-21

    Agricultural ammonia (NH3) emissions (90% of total EU emissions) are responsible for about 45% airborne eutrophication, 31% soil acidification and 12% fine dust formation within the EU15. But NH3 emissions also mean a considerable loss of nutrients. Many studies on NH3 emission from organic and mineral fertilizer application have been performed in recent decades. Nevertheless, research related to NH3 emissions after application fertilizers is still limited in particular with respect to relationships to emissions, fertilizer type, site conditions and crop growth. Due to the variable response of crops to treatments, effects can only be validated in experimental designs including field replication for statistical testing. The dominating ammonia loss methods yielding quantitative emissions require large field areas, expensive equipment or current supply, which restricts their application in replicated field trials. This protocol describes a new methodology for the measurement of NH3 emissions on many plots linking a simple semi-quantitative measuring method used in all plots, with a quantitative method by simultaneous measurements using both methods on selected plots. As a semi-quantitative measurement method passive samplers are used. The second method is a dynamic chamber method (Dynamic Tube Method) to obtain a transfer quotient, which converts the semi-quantitative losses of the passive sampler to quantitative losses (kg nitrogen ha(-1)). The principle underlying this approach is that passive samplers placed in a homogeneous experimental field have the same NH3 absorption behavior under identical environmental conditions. Therefore, a transfer co-efficient obtained from single passive samplers can be used to scale the values of all passive samplers used in the same field trial. The method proved valid under a wide range of experimental conditions and is recommended to be used under conditions with bare soil or small canopies (<0.3 m). Results obtained from experiments with taller plants should be treated more carefully.

  13. Calibrated Passive Sampling - Multi-plot Field Measurements of NH3 Emissions with a Combination of Dynamic Tube Method and Passive Samplers

    PubMed Central

    Pacholski, Andreas

    2016-01-01

    Agricultural ammonia (NH3) emissions (90% of total EU emissions) are responsible for about 45% airborne eutrophication, 31% soil acidification and 12% fine dust formation within the EU15. But NH3 emissions also mean a considerable loss of nutrients. Many studies on NH3 emission from organic and mineral fertilizer application have been performed in recent decades. Nevertheless, research related to NH3 emissions after application fertilizers is still limited in particular with respect to relationships to emissions, fertilizer type, site conditions and crop growth. Due to the variable response of crops to treatments, effects can only be validated in experimental designs including field replication for statistical testing. The dominating ammonia loss methods yielding quantitative emissions require large field areas, expensive equipment or current supply, which restricts their application in replicated field trials. This protocol describes a new methodology for the measurement of NH3 emissions on many plots linking a simple semi-quantitative measuring method used in all plots, with a quantitative method by simultaneous measurements using both methods on selected plots. As a semi-quantitative measurement method passive samplers are used. The second method is a dynamic chamber method (Dynamic Tube Method) to obtain a transfer quotient, which converts the semi-quantitative losses of the passive sampler to quantitative losses (kg nitrogen ha-1). The principle underlying this approach is that passive samplers placed in a homogeneous experimental field have the same NH3 absorption behavior under identical environmental conditions. Therefore, a transfer co-efficient obtained from single passive samplers can be used to scale the values of all passive samplers used in the same field trial. The method proved valid under a wide range of experimental conditions and is recommended to be used under conditions with bare soil or small canopies (<0.3 m). Results obtained from experiments with taller plants should be treated more carefully. PMID:27023010

  14. Partitioning of fluoranthene between free and bound forms in stormwater runoff and other urban discharges using passive dosing.

    PubMed

    Birch, Heidi; Mayer, Philipp; Lützhøft, Hans-Christian Holten; Mikkelsen, Peter Steen

    2012-11-15

    Partitioning of fluoranthene in stormwater runoff and other urban discharges was measured by a new analytical method based on passive dosing. Samples were collected at the inlet (n = 11) and outlet (n = 8) from a stormwater retention pond in Albertslund (Denmark), and for comparison samples were also obtained at a municipal wastewater treatment plant, a power plant, a contaminated site and a waste deposit in Copenhagen (n = 1 at each site). The freely dissolved concentration of (14)C-fluoranthene in the samples was controlled by equilibrium partitioning from a pre-loaded polymer and the total sample concentration measured. The measurements yielded free fractions of fluoranthene in stormwater in the range 0.04-0.15 in the inlet during the first part of the runoff events increasing to 0.3-0.5 at the end of the events and in the outlet from the retention pond. The enhanced capacity of the different stormwater samples for carrying fluoranthene was 2-23 relative to pure water and decreasing during rain events. The enhanced capacity of stormwater showed a different relationship with suspended solid concentrations than the other types of urban discharges. Partitioning of fluoranthene to dissolved organic carbon was lower than partitioning to particulate organic carbon. Partitioning of fluoranthene to particulate organic matter in the 19 stormwater samples yielded a log K(POM) of 5.18. The presented results can be used in stormwater quality modeling and assessment of efficiency of stormwater treatment systems. This work also shows the potential of the passive dosing method to obtain conversion factors between total concentrations, which are needed for comparison with water quality criteria, and freely dissolved concentrations, which are more related to toxicity and obtained by the use of most passive samplers. Copyright © 2012 Elsevier Ltd. All rights reserved.

  15. Estimation of Snow Parameters Based on Passive Microwave Remote Sensing and Meteorological Information

    NASA Technical Reports Server (NTRS)

    Tsang, Leung; Hwang, Jenq-Neng

    1996-01-01

    A method to incorporate passive microwave remote sensing measurements within a spatially distributed snow hydrology model to provide estimates of the spatial distribution of Snow Water Equivalent (SWE) as a function of time is implemented. The passive microwave remote sensing measurements are at 25 km resolution. However, in mountain regions the spatial variability of SWE over a 25 km footprint is large due to topographic influences. On the other hand, the snow hydrology model has built-in topographic information and the capability to estimate SWE at a 1 km resolution. In our work, the snow hydrology SWE estimates are updated and corrected using SSM/I passive microwave remote sensing measurements. The method is applied to the Upper Rio Grande River Basin in the mountains of Colorado. The change in prediction of SWE from hydrology modeling with and without updating is compared with measurements from two SNOTEL sites in and near the basin. The results indicate that the method incorporating the remote sensing measurements into the hydrology model is able to more closely estimate the temporal evolution of the measured values of SWE as a function of time.

  16. Passive Measurements of Thoron and its Progeny in some Dwellings in Ireland

    NASA Astrophysics Data System (ADS)

    Choncubhair, Órlaith Ní; Laughlin, James Mc; Tokonami, Shinji

    2008-08-01

    In this paper, an account is given of the development, calibration and field use of a passive alpha track detector sensitive to thoron as well as to radon. No database of thoron and thoron progeny concentrations in dwellings in Ireland exists and, as a result, the level of exposure of the Irish population to thoron and its progeny is unknown. As an initial or pilot stage in establishing such a data base measurements of thoron and thoron progeny concentrations (the latter expressed in Equilibrium Equivalent Thoron Concentration (EETC)) were made in 40 randomly chosen Irish dwellings. The EETC measurements were made using a passive thoron progeny deposition rate monitor designed and supplied by NIRS (Japan). In addition standard unmodified SSI passive radon detectors were used to measure radon in these dwellings. The measured thoron concentrations ranged from below the level of detection to 154 Bq/m3 while the radon gas ranged from 15 to 179 Bq/m3. The thoron progeny EETC values for these dwellings ranged from 0.03 to 7.7 Bq/m3. An account is also given of the dosimetric implications of these measurements.

  17. Research on LQR optimal control method of active engine mount

    NASA Astrophysics Data System (ADS)

    Huan, Xie; Yu, Duan

    2018-04-01

    In this paper, the LQR control method is applied to the active mount of the engine, and a six-cylinder engine excitation model is established. Through the joint simulation of AMESim and MATLAB, the vibration isolation performance of the active mount system and the passive mount system is analyzed. Excited by the multi-engine operation, the simulation results of the vertical displacement, acceleration and dynamic deflection of the vehicle body show that the vibration isolation capability of the active mount system is superior to that of the passive mount system. It shows that compared with the passive mount, LQR active mount can greatly improve the vibration isolation performance, which proves the feasibility and effectiveness of the LQR control method.

  18. The surface characterization and passive behavior of Type 316L stainless steel in H2S-containing conditions

    NASA Astrophysics Data System (ADS)

    Wang, Zhu; Zhang, Lei; Tang, Xian; Zhang, Ziru; Lu, Minxu

    2017-11-01

    The protectiveness and characterization of passive films formed at various potentials in H2S-containing environments were studied using electrochemical measurements and surface analysis method. The corrosion resistance of 316L in H2S-containing environment decreases with the applied potential. The Auger electron spectroscopy (AES) and X-ray photoelectron spectroscopy (XPS) results indicate that Ni participates in the film formation, which results in the corresponding enrichment in the passive film. The oxidization degree analysis indicates that metallic elements are present in the passive film. Sulfide ions are significantly favored in the passive film at higher potentials, which is responsible for the breakdown of passive film.

  19. Lexically Specific Knowledge and Individual Differences in Adult Native Speakers' Processing of the English Passive

    ERIC Educational Resources Information Center

    Street, James A.; Dabrowska, Ewa

    2014-01-01

    This article provides experimental evidence for the role of lexically specific representations in the processing of passive sentences and considerable education-related differences in comprehension of the passive construction. The experiment measured response time and decision accuracy of participants with high and low academic attainment using an…

  20. PASSIVE AEROSOL SAMPLER FOR CHARACTERIZATION, AMBIENT CONCENTRATION, AND PARTICLE SIZE MEASUREMENT

    EPA Science Inventory

    This is an extended abstract of a presentation made at the Air and Waste Management Association's Symposium on Air Quality Measurement Methods and Technology, Durham, NC, May 9-11, 2006. The abstract describes the theory, design, and initial testing of a passive aerosol sampler f...

  1. Overview of the NASA soil moisture active/passive mission

    USDA-ARS?s Scientific Manuscript database

    The NASA Soil Moisture Active Passive (SMAP) Mission is currently in design Phase C and scheduled for launch in October 2014. Its mission concept is based on combined L-band radar and radiometry measurements obtained from a shared, rotating 6-meter antennae. These measurements will be used to retrie...

  2. Numerical simulation of the control of the three-dimensional transition process in boundary layers

    NASA Technical Reports Server (NTRS)

    Kral, L. D.; Fasel, H. F.

    1990-01-01

    Surface heating techniques to control the three-dimensional laminar-turbulent transition process are numerically investigated for a water boundary layer. The Navier-Stokes and energy equations are solved using a fully implicit finite difference/spectral method. The spatially evolving boundary layer is simulated. Results of both passive and active methods of control are shown for small amplitude two-dimensional and three-dimensional disturbance waves. Control is also applied to the early stages of the secondary instability process using passive or active control techniques.

  3. A comparative study of frictional force in self-ligating brackets according to the bracket-archwire angulation, bracket material, and wire type

    PubMed Central

    Lee, Souk Min

    2015-01-01

    Objective This study aimed to compare the frictional force (FR) in self-ligating brackets among different bracket-archwire angles, bracket materials, and archwire types. Methods Passive and active metal self-ligating brackets and active ceramic self-ligating brackets were included as experimental groups, while conventional twin metal brackets served as a control group. All brackets were maxillary premolar brackets with 0.022 inch [in] slots and a -7° torque. The orthodontic wires used included 0.018 round and 0.019 × 0.025 in rectangular stainless steel wires. The FR was measured at 0°, 5°, and 10° angulations as the wire was drawn through the bracket slots after attaching brackets from each group to the universal testing machine. Static and kinetic FRs were also measured. Results The passive self-ligating brackets generated a lower FR than all the other brackets. Static and kinetic FRs generally increased with an increase in the bracket-archwire angulation, and the rectangular wire caused significantly higher static and kinetic FRs than the round wire (p < 0.001). The metal passive self-ligating brackets exhibited the lowest static FR at the 0° angulation and a lower increase in static and kinetic FRs with an increase in bracket-archwire angulation than the other brackets, while the conventional twin brackets showed a greater increase than all three experimental brackets. Conclusions The passive self-ligating brackets showed the lowest FR in this study. Self-ligating brackets can generate varying FRs in vitro according to the wire size, surface characteristics, and bracket-archwire angulation. PMID:25667913

  4. PASSIVE MECHANICAL PROPERTIES AND RELATED PROTEINS CHANGE WITH BOTULINUM NEUROTOXIN A INJECTION OF NORMAL SKELETAL MUSCLE

    PubMed Central

    Thacker, Bryan E.; Tomiya, Akihito; Hulst, Jonah B.; Suzuki, Kentaro P.; Bremner, Shannon N.; Gastwirt, Randy F.; Greaser, Marion L.; Lieber, Richard L.; Ward, Samuel R.

    2011-01-01

    Summary The effects of botulinum neurotoxin A on the passive mechanical properties of skeletal muscle have not been investigated, but may have significant impact in the treatment of neuromuscular disorders including spasticity. Single fiber and fiber bundle passive mechanical testing was performed on rat muscles treated with botulinum neurotoxin A. Myosin heavy chain and titin composition of single fibers was determined by gel electrophoresis. Muscle collagen content was determined using a hydroxyproline assay. Neurotoxin-treated single fiber passive elastic modulus was reduced compared to control fibers (53.00 kPa versus 63.43 kPa). Fiber stiffness and slack sarcomere length were also reduced compared to control fibers and myosin heavy chain composition shifted from faster to slower isoforms. Average titin molecular weight increased 1.77% after treatment. Fiber bundle passive elastic modulus increased following treatment (168.83 kPa versus 75.14 kPa). Bundle stiffness also increased while collagen content per mass of muscle tissue increased 38%. Injection of botulinum neurotoxin A produces an effect on the passive mechanical properties of normal muscle that is opposite to the changes observed in spastic muscles. PMID:21853457

  5. Passive mechanical properties and related proteins change with botulinum neurotoxin A injection of normal skeletal muscle.

    PubMed

    Thacker, Bryan E; Tomiya, Akihito; Hulst, Jonah B; Suzuki, Kentaro P; Bremner, Shannon N; Gastwirt, Randy F; Greaser, Marion L; Lieber, Richard L; Ward, Samuel R

    2012-03-01

    The effects of botulinum neurotoxin A on the passive mechanical properties of skeletal muscle have not been investigated, but may have significant impact in the treatment of neuromuscular disorders including spasticity. Single fiber and fiber bundle passive mechanical testing was performed on rat muscles treated with botulinum neurotoxin A. Myosin heavy chain and titin composition of single fibers was determined by gel electrophoresis. Muscle collagen content was determined using a hydroxyproline assay. Neurotoxin-treated single fiber passive elastic modulus was reduced compared to control fibers (53.00 kPa vs. 63.43 kPa). Fiber stiffness and slack sarcomere length were also reduced compared to control fibers and myosin heavy chain composition shifted from faster to slower isoforms. Average titin molecular weight increased 1.77% after treatment. Fiber bundle passive elastic modulus increased following treatment (168.83  kPa vs. 75.14 kPa). Bundle stiffness also increased while collagen content per mass of muscle tissue increased 38%. Injection of botulinum neurotoxin A produces an effect on the passive mechanical properties of normal muscle that is opposite to the changes observed in spastic muscles. Copyright © 2011 Orthopaedic Research Society.

  6. Etching radical controlled gas chopped deep reactive ion etching

    DOEpatents

    Olynick, Deidre; Rangelow, Ivo; Chao, Weilun

    2013-10-01

    A method for silicon micromachining techniques based on high aspect ratio reactive ion etching with gas chopping has been developed capable of producing essentially scallop-free, smooth, sidewall surfaces. The method uses precisely controlled, alternated (or chopped) gas flow of the etching and deposition gas precursors to produce a controllable sidewall passivation capable of high anisotropy. The dynamic control of sidewall passivation is achieved by carefully controlling fluorine radical presence with moderator gasses, such as CH.sub.4 and controlling the passivation rate and stoichiometry using a CF.sub.2 source. In this manner, sidewall polymer deposition thicknesses are very well controlled, reducing sidewall ripples to very small levels. By combining inductively coupled plasmas with controlled fluorocarbon chemistry, good control of vertical structures with very low sidewall roughness may be produced. Results show silicon features with an aspect ratio of 20:1 for 10 nm features with applicability to nano-applications in the sub-50 nm regime. By comparison, previous traditional gas chopping techniques have produced rippled or scalloped sidewalls in a range of 50 to 100 nm roughness.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Passerini, Stefano; Ponciroli, Roberto; Vilim, Richard B.

    Here, the interaction of the active control system with passive safety behavior is investigated for sodium-cooled fast reactors. A claim often made of advanced reactors is that they are passively safe against unprotected upset events. In practice, such upset events are not analyzed in the context of the plant control system, but rather the analyses are performed without considering the normally programmed response of the control system (open-loop approach). This represents an oversimplification of the safety case. The issue of passive safety override arises since the control system commands actuators whose motions have safety consequences. Depending on the upset involvingmore » the control system ( operator error, active control system failure, or inadvertent control system override), an actuator does not necessarily go in the same direction as needed for safety. So neglecting to account for control system action during an unprotected upset is nonconservative from a safety standpoint. It is important then, during the design of the plant, to consider the potential for the control system to work against the inherent and safe regulating effects of purposefully engineered temperature feedbacks.« less

  8. Epidemiologic methods in mastitis treatment and control.

    PubMed

    Thurmond, M C

    1993-11-01

    Methods and concepts of epidemiology offer means whereby udder health can be monitored and evaluated. Prerequisite to a sound epidemiologic approach is development of measures of mastitis that minimize biases and that account for sensitivity and specificity of diagnostic tests. Mastitis surveillance offers an ongoing and passive system for evaluation of udder health, whereas clinical and observational trials offer a more proactive and developmental approach to improving udder health.

  9. Silicone passive equilibrium samplers as 'chemometers' in eels and sediments of a Swedish lake.

    PubMed

    Jahnke, Annika; Mayer, Philipp; McLachlan, Michael S; Wickström, Håkan; Gilbert, Dorothea; MacLeod, Matthew

    2014-03-01

    Passive equilibrium samplers deployed in two or more media of a system and allowed to come to equilibrium can be viewed as 'chemometers' that reflect the difference in chemical activities of contaminants between the media. We applied silicone-based equilibrium samplers to measure relative chemical activities of seven 'indicator' polychlorinated biphenyls (PCBs) and hexachlorobenzene in eels and sediments from a Swedish lake. Chemical concentrations in eels and sediments were also measured using exhaustive extraction methods. Lipid-normalized concentrations in eels were higher than organic carbon-normalized concentrations in sediments, with biota-sediment accumulation factors (BSAFs) of five PCBs ranging from 2.7 to 12.7. In contrast, chemical activities of the same pollutants inferred by passive sampling were 3.5 to 31.3 times lower in eels than in sediments. The apparent contradiction between BSAFs and activity ratios is consistent with the sorptive capacity of lipids exceeding that of sediment organic carbon from this ecosystem by up to 50-fold. Factors that may contribute to the elevated activity in sediments are discussed, including slower response of sediments than water to reduced emissions, sediment diagenesis and sorption to phytoplankton. The 'chemometer' approach has the potential to become a powerful tool to study the thermodynamic controls on persistent organic chemicals in the environment and should be extended to other environmental compartments.

  10. Yoga leads to multiple physical improvements after stroke, a pilot study.

    PubMed

    Schmid, Arlene A; Miller, Kristine K; Van Puymbroeck, Marieke; DeBaun-Sprague, Erin

    2014-12-01

    To assess change in physical functioning (pain, range of motion (ROM), strength, and endurance) after 8 weeks of therapeutic-yoga. Planned analyses of data from a randomized pilot study of yoga after stroke. University-based research laboratory. People with chronic stroke (N=47) randomized to therapeutic-yoga (n=37) or wait-list control (n=10). 16 sessions of therapeutic yoga (twice a week/8 weeks). Yoga was delivered in a standardized and progressive format with postures, breathing, and meditation, and relaxation in sitting, standing, and supine. Pain was assessed with the PEG, a 3-item functional measure of the interference of pain. ROM included neck and hip active and passive ROM measurements). Upper and lower extremity strength were assessed with the arm curl test and chair-to-stand test, respectively. Endurance was assessed with the 6-minute walk and modified 2-min step test. After a Bonferroni Correction, pain, neck ROM, hip passive ROM, upper extremity strength, and the 6-min walk scores all significantly improved after 8 weeks of engaging in yoga. No changes occurred in the wait-list control group. A group therapeutic-yoga intervention may improve multiple aspects of physical functioning after stroke. Such an intervention may be complementary to traditional rehabilitation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Fiber-optic sensing in cryogenic environments. [for rocket propellant tank monitoring

    NASA Technical Reports Server (NTRS)

    Sharma, M.; Brooks, R. E.

    1980-01-01

    Passive optical sensors using fiber-optic signal transmission to a remote monitoring station are explored as an alternative to electrical sensors used to monitor the status of explosive propellants. The designs of passive optical sensors measuring liquid level, pressure, and temperature in cryogenic propellant tanks are discussed. Test results for an experimental system incorporating these sensors and operating in liquid nitrogen demonstrate the feasibility of passive sensor techniques and indicate that they can serve as non-hazardous replacements for more conventional measuring equipment in explosive environments.

  12. Active Flexion in Weight Bearing Better Correlates with Functional Outcomes of Total Knee Arthroplasty than Passive Flexion.

    PubMed

    Song, Young Dong; Jain, Nimash; Kang, Yeon Gwi; Kim, Tae Yune; Kim, Tae Kyun

    2016-06-01

    Correlations between maximum flexion and functional outcomes in total knee arthroplasty (TKA) patients are reportedly weak. We investigated whether there are differences between passive maximum flexion in nonweight bearing and other types of maximum flexion and whether the type of maximum flexion correlates with functional outcomes. A total of 210 patients (359 knees) underwent preoperative evaluation and postoperative follow-up evaluations (6, 12, and 24 months) for the assessment of clinical outcomes including maximum knee flexion. Maximum flexion was measured under five conditions: passive nonweight bearing, passive weight bearing, active nonweight bearing, and active weight bearing with or without arm support. Data were analyzed for relationships between passive maximum flexion in nonweight bearing by Pearson correlation analyses, and a variance comparison between measurement techniques via paired t test. We observed substantial differences between passive maximum flexion in nonweight bearing and the other four maximum flexion types. At all time points, passive maximum flexion in nonweight bearing correlated poorly with active maximum flexion in weight bearing with or without arm support. Active maximum flexion in weight bearing better correlated with functional outcomes than the other maximum flexion types. Our study suggests active maximum flexion in weight bearing should be reported together with passive maximum flexion in nonweight bearing in research on the knee motion arc after TKA.

  13. Active Flexion in Weight Bearing Better Correlates with Functional Outcomes of Total Knee Arthroplasty than Passive Flexion

    PubMed Central

    Song, Young Dong; Jain, Nimash; Kang, Yeon Gwi; Kim, Tae Yune

    2016-01-01

    Purpose Correlations between maximum flexion and functional outcomes in total knee arthroplasty (TKA) patients are reportedly weak. We investigated whether there are differences between passive maximum flexion in nonweight bearing and other types of maximum flexion and whether the type of maximum flexion correlates with functional outcomes. Materials and Methods A total of 210 patients (359 knees) underwent preoperative evaluation and postoperative follow-up evaluations (6, 12, and 24 months) for the assessment of clinical outcomes including maximum knee flexion. Maximum flexion was measured under five conditions: passive nonweight bearing, passive weight bearing, active nonweight bearing, and active weight bearing with or without arm support. Data were analyzed for relationships between passive maximum flexion in nonweight bearing by Pearson correlation analyses, and a variance comparison between measurement techniques via paired t test. Results We observed substantial differences between passive maximum flexion in nonweight bearing and the other four maximum flexion types. At all time points, passive maximum flexion in nonweight bearing correlated poorly with active maximum flexion in weight bearing with or without arm support. Active maximum flexion in weight bearing better correlated with functional outcomes than the other maximum flexion types. Conclusions Our study suggests active maximum flexion in weight bearing should be reported together with passive maximum flexion in nonweight bearing in research on the knee motion arc after TKA. PMID:27274468

  14. Effects of NOX Storage Component on Ammonia Formation in TWC for Passive SCR NOX Control in Lean Gasoline Engines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prikhodko, Vitaly Y.; Pihl, Josh A.; Toops, Todd J.

    A prototype three-way catalyst (TWC) with NOX storage component was evaluated for ammonia (NH3) generation on a 2.0-liter BMW lean burn gasoline direct injection engine as a component in a passive ammonia selective catalytic reduction (SCR) system. The passive NH3 SCR system is a potential approach for controlling nitrogen oxides (NOX) emissions from lean burn gasoline engines. In this system, NH3 is generated over a close-coupled TWC during periodic slightly-rich engine operation and subsequently stored on an underfloor SCR catalyst. Upon switching to lean, NOX passes through the TWC and is reduced by the stored NH3 on the SCR catalyst.more » Adding a NOX storage component to a TWC provides two benefits in the context of a passive SCR system: (1) enabling longer lean operation by storing NOX upstream and preserving NH3 inventory on the downstream SCR catalyst; and (2) increasing the quantity and rate of NH3 production during rich operation. Since the fuel penalty associated with passive SCR NOX control depends on the fraction of time that the engine is running rich rather than lean, both benefits (longer lean times and shorter rich times achieved via improved NH3 production) will decrease the passive SCR fuel penalty. However, these benefits are primarily realized at low to moderate temperatures (300-500 °C), where the NOX storage component is able to store NOX, with little to no benefit at higher temperatures (>500 °C), where NOX storage is no longer effective. This study discusses engine parameters and control strategies affecting the NH3 generation over a TWC with NOX storage component.« less

  15. Pressure oscillations occurring in a centrifugal compressor system with and without passive and active surge control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jungowski, W.M.; Weiss, M.H.; Price, G.R.

    1996-01-01

    A study of pressure oscillations occurring in small centrifugal compressor systems without a plenum is presented. Active and passive surge control were investigated theoretically and experimentally for systems with various inlet and discharge piping configurations. The determination of static and dynamic stability criteria was based on Greitzer`s (1981) lumped parameter model modified to accommodate capacitance of the piping. Experimentally, passive control using globe valves closely coupled to the compressor prevented the occurrence of surge even with the flow reduced to zero. Active control with a sleeve valve located at the compressor was effective but involved a significant component of passivemore » throttling which reduced the compressor efficiency. With an oscillator connected to a short side branch at the compressor, effective active control was achieved without throttling. Both methods of active control reduced the flow rate at surge onset by about 30%. In general, the experiments qualitatively confirmed the derived stability criteria.« less

  16. Reducing model uncertainty effects in flexible manipulators through the addition of passive damping

    NASA Technical Reports Server (NTRS)

    Alberts, T. E.

    1987-01-01

    An important issue in the control of practical systems is the effect of model uncertainty on closed loop performance. This is of particular concern when flexible structures are to be controlled, due to the fact that states associated with higher frequency vibration modes are truncated in order to make the control problem tractable. Digital simulations of a single-link manipulator system are employed to demonstrate that passive damping added to the flexible member reduces adverse effects associated with model uncertainty. A controller was designed based on a model including only one flexible mode. This controller was applied to larger order systems to evaluate the effects of modal truncation. Simulations using a Linear Quadratic Regulator (LQR) design assuming full state feedback illustrate the effect of control spillover. Simulations of a system using output feedback illustrate the destabilizing effect of observation spillover. The simulations reveal that the system with passive damping is less susceptible to these effects than the untreated case.

  17. Deficits in agency in schizophrenia, and additional deficits in body image, body schema, and internal timing, in passivity symptoms.

    PubMed

    Graham, Kyran T; Martin-Iverson, Mathew T; Holmes, Nicholas P; Jablensky, Assen; Waters, Flavie

    2014-01-01

    Individuals with schizophrenia, particularly those with passivity symptoms, may not feel in control of their actions, believing them to be controlled by external agents. Cognitive operations that contribute to these symptoms may include abnormal processing in agency as well as body representations that deal with body schema and body image. However, these operations in schizophrenia are not fully understood, and the questions of general versus specific deficits in individuals with different symptom profiles remain unanswered. Using the projected-hand illusion (a digital video version of the rubber-hand illusion) with synchronous and asynchronous stroking (500 ms delay), and a hand laterality judgment task, we assessed sense of agency, body image, and body schema in 53 people with clinically stable schizophrenia (with a current, past, and no history of passivity symptoms) and 48 healthy controls. The results revealed a stable trait in schizophrenia with no difference between clinical subgroups (sense of agency) and some quantitative (specific) differences depending on the passivity symptom profile (body image and body schema). Specifically, a reduced sense of self-agency was a common feature of all clinical subgroups. However, subgroup comparisons showed that individuals with passivity symptoms (both current and past) had significantly greater deficits on tasks assessing body image and body schema, relative to the other groups. In addition, patients with current passivity symptoms failed to demonstrate the normal reduction in body illusion typically seen with a 500 ms delay in visual feedback (asynchronous condition), suggesting internal timing problems. Altogether, the results underscore self-abnormalities in schizophrenia, provide evidence for both trait abnormalities and state changes specific to passivity symptoms, and point to a role for internal timing deficits as a mechanistic explanation for external cues becoming a possible source of self-body input.

  18. Increased oxidative stress in preschool children exposed to passive smoking.

    PubMed

    Yıldırım, Faruk; Sermetow, Kabil; Aycicek, Ali; Kocyigit, Abdurrahim; Erel, Ozcan

    2011-01-01

    To study the effect of passive cigarette smoking on plasma oxidative and antioxidative status in passive smoking preschool children and to compare them with controls. Thirty-four passive smoking (five to 50 cigarettes per day) preschool children (study group) and 32 controls who had never been exposed to cigarette smoke were randomly chosen from children aged from 4 to 6 years. Urinary cotinine and plasma indicators of oxidative and antioxidative status, i.e., total oxidant status (TOS), total antioxidant capacity (TAC), and oxidative stress index (OSI), were determined. Mean environmental cigarette consumption was 22±13 cigarettes per day in passive smoking children. Mean urinary cotinine levels were 77.6±41.4 ng/mL and 11.9±2.3 ng/mL in the study and control groups, respectively (p < 0.001). Mean plasma TAC levels were 0.95±0.13 mmol Trolox equivalent/L and 1.01±0.09 mmol Trolox equivalent/L, respectively (p = 0.039). Mean plasma TOS levels were 28.6±7.9 µmol H2O2 equivalent/L and 18.5±6.3 µmol H2O2 equivalent/L, respectively (p < 0.001). Mean OSI levels were 3.08±0.98 arbitrary units and 1.84±0.64 arbitrary units, respectively (p < 0.001). A small amount of cigarette smoke (five to 10 cigarettes per day) causes considerable oxidative stress. There were significant correlations between number of cigarettes consumed and oxidant status and OSI levels. Passive smoke is a potent oxidant in preschool children. Its deleterious effects are not limited just to heavy passive smoking, but also occur with exposure to small amounts of smoke.

  19. Predicting Fluid Responsiveness by Passive Leg Raising: A Systematic Review and Meta-Analysis of 23 Clinical Trials.

    PubMed

    Cherpanath, Thomas G V; Hirsch, Alexander; Geerts, Bart F; Lagrand, Wim K; Leeflang, Mariska M; Schultz, Marcus J; Groeneveld, A B Johan

    2016-05-01

    Passive leg raising creates a reversible increase in venous return allowing for the prediction of fluid responsiveness. However, the amount of venous return may vary in various clinical settings potentially affecting the diagnostic performance of passive leg raising. Therefore we performed a systematic meta-analysis determining the diagnostic performance of passive leg raising in different clinical settings with exploration of patient characteristics, measurement techniques, and outcome variables. PubMed, EMBASE, the Cochrane Database of Systematic Reviews, and citation tracking of relevant articles. Clinical trials were selected when passive leg raising was performed in combination with a fluid challenge as gold standard to define fluid responders and non-responders. Trials were included if data were reported allowing the extraction of sensitivity, specificity, and area under the receiver operating characteristic curve. Twenty-three studies with a total of 1,013 patients and 1,034 fluid challenges were included. The analysis demonstrated a pooled sensitivity of 86% (95% CI, 79-92), pooled specificity of 92% (95% CI, 88-96), and a summary area under the receiver operating characteristic curve of 0.95 (95% CI, 0.92-0.98). Mode of ventilation, type of fluid used, passive leg raising starting position, and measurement technique did not affect the diagnostic performance of passive leg raising. The use of changes in pulse pressure on passive leg raising showed a lower diagnostic performance when compared with passive leg raising-induced changes in flow variables, such as cardiac output or its direct derivatives (sensitivity of 58% [95% CI, 44-70] and specificity of 83% [95% CI, 68-92] vs sensitivity of 85% [95% CI, 78-90] and specificity of 92% [95% CI, 87-94], respectively; p < 0.001). Passive leg raising retains a high diagnostic performance in various clinical settings and patient groups. The predictive value of a change in pulse pressure on passive leg raising is inferior to a passive leg raising-induced change in a flow variable.

  20. Modelling and Vibration Control of Beams with Partially Debonded Active Constrained Layer Damping Patch

    NASA Astrophysics Data System (ADS)

    SUN, D.; TONG, L.

    2002-05-01

    A detailed model for the beams with partially debonded active constraining damping (ACLD) treatment is presented. In this model, the transverse displacement of the constraining layer is considered to be non-identical to that of the host structure. In the perfect bonding region, the viscoelastic core is modelled to carry both peel and shear stresses, while in the debonding area, it is assumed that no peel and shear stresses be transferred between the host beam and the constraining layer. The adhesive layer between the piezoelectric sensor and the host beam is also considered in this model. In active control, the positive position feedback control is employed to control the first mode of the beam. Based on this model, the incompatibility of the transverse displacements of the active constraining layer and the host beam is investigated. The passive and active damping behaviors of the ACLD patch with different thicknesses, locations and lengths are examined. Moreover, the effects of debonding of the damping layer on both passive and active control are examined via a simulation example. The results show that the incompatibility of the transverse displacements is remarkable in the regions near the ends of the ACLD patch especially for the high order vibration modes. It is found that a thinner damping layer may lead to larger shear strain and consequently results in a larger passive and active damping. In addition to the thickness of the damping layer, its length and location are also key factors to the hybrid control. The numerical results unveil that edge debonding can lead to a reduction of both passive and active damping, and the hybrid damping may be more sensitive to the debonding of the damping layer than the passive damping.

  1. Air pollution measurements from satellites

    NASA Technical Reports Server (NTRS)

    Ludwig, C. B.; Griggs, M.; Malkmus, W.; Bartle, E. R.

    1973-01-01

    A study is presented on the remote sensing of gaseous and particulate air pollutants which is an extension of a previous report. Pollutants can be observed by either active or passive remote sensing systems. Calculations discussed herein indicate that tropospheric CO, CO2, SO2, NO2, NH3, HCHO, and CH4 can be measured by means of nadir looking passive systems. Additional species such as NO, HNO3, O3, and H2O may be measured in the stratosphere through a horizon experiment. A brief theoretical overview of resonance Raman scattering and resonance fluorescence is given. It is found that radiance measurements are most promising for general global applications, and that stratospheric aerosols may be measured using a sun occultation technique. The instrumentation requirements for both active and passive systems are examined and various instruments now under development are described.

  2. Air sampling procedures to evaluate microbial contamination: a comparison between active and passive methods in operating theatres.

    PubMed

    Napoli, Christian; Marcotrigiano, Vincenzo; Montagna, Maria Teresa

    2012-08-02

    Since air can play a central role as a reservoir for microorganisms, in controlled environments such as operating theatres regular microbial monitoring is useful to measure air quality and identify critical situations. The aim of this study is to assess microbial contamination levels in operating theatres using both an active and a passive sampling method and then to assess if there is a correlation between the results of the two different sampling methods. The study was performed in 32 turbulent air flow operating theatres of a University Hospital in Southern Italy. Active sampling was carried out using the Surface Air System and passive sampling with settle plates, in accordance with ISO 14698. The Total Viable Count (TVC) was evaluated at rest (in the morning before the beginning of surgical activity) and in operational (during surgery). The mean TVC at rest was 12.4 CFU/m3 and 722.5 CFU/m2/h for active and passive samplings respectively. The mean in operational TVC was 93.8 CFU/m3 (SD = 52.69; range = 22-256) and 10496.5 CFU/m2/h (SD = 7460.5; range = 1415.5-25479.7) for active and passive samplings respectively. Statistical analysis confirmed that the two methods correlate in a comparable way with the quality of air. It is possible to conclude that both methods can be used for general monitoring of air contamination, such as routine surveillance programs. However, the choice must be made between one or the other to obtain specific information.

  3. Development of a silicone-membrane passive sampler for monitoring cylindrospermopsin and microcystin LR-YR-RR in natural waters

    NASA Astrophysics Data System (ADS)

    Nyoni, Hlengilizwe; Mamba, Bhekie B.; Msagati, Titus A. M.

    2017-08-01

    Silicone membrane tubes were functionalised by filling them with synthesised γ-Fe2O3 nanoparticles and used as a passive sampling device for monitoring microcystins and cylindrospermopsin in aquatic environments. This novel device was calibrated for the measurement of microcystin and cylindrospermopsin concentrations in water. The effect of temperature and hydrodynamics on the sampler performance was studied in a flow-through system under controlled conditions. The chemical uptake of microcystins (MCs) and cylindrospermopsin (CYN) into the passive sampler remained linear and integrative throughout the exposure period. The rate of accumulation of most of the MC compounds tested was dependent on temperature and flow velocity. The use of 13C labelled polychlorinated biphenyls as performance reference compounds (PRCs) in silicone membrane/γ-Fe2O3 nanoparticle passive sampler, Chemcatcher and polar organic chemical integrative sampler (POCIS) was evaluated. The majority of PRCs improved the semi quantitative nature of water concentration estimated by the three samplers. The corrected sampling rate values of model biotoxin compounds were used to estimate the time-weighted average concentrations in natural cyanobacterial water blooms of the Hartbeespoort dam. The corrected sampling rates RScorr values varied from 0.1140 to 0.5628 Ld-1 between samplers with silicone membrane having the least RScorr values compared to the Chemcatcher and POCIS. The three passive sampling devises provided a more relevant picture of the biotoxin concentration in the Hartbeespoort dam. The results suggested that the three sampling devices are suitable for use in monitoring microcystins and cylindrospermopsin concentrations in aquatic environments.

  4. Vibration isolation analysis of new design OEM damper for malaysia vehicle suspension system featuring MR fluid

    NASA Astrophysics Data System (ADS)

    Unuh, M. H.; Muhamad, P.; Norfazrina, H. M. Y.; Ismail, M. A.; Tanasta, Z.

    2018-01-01

    The applications of semi-active damper employing magnetorheological (MR) fluids keep increasing in fulfilling the demand to control undesired vibration effect. The aim of this study is to introduce the new design of damper for Malaysian vehicle model as well to evaluate its effectiveness in promoting comfort. The vibration isolation performance of the OEM damper featuring MR fluid was analysed physically under real road profile excitation experimentally. An experiment using quarter car rig suspension and LMS SCADAS Mobile was conducted to demonstrate the influence of current in controlling the characteristics of MR fluid in alter the damping behaviour under 5 cm bump impact. Subsequently, the displacement values were measured with respect to time. The new design OEM damper featuring MR fluid was validated by comparing the data with original equipment manufacturer (OEM) passive damper results under the same approach of testing. Comparison of numerical data of the new design OEM damper shown that it can reduce the excitation amplitude up to 40% compared to those obtained by OEM passive damper. Finally, the new design OEM damper featuring MR fluid has effectively isolated the disturbance from the road profile and control the output force.

  5. Modular Wideband Active Vibration Absorber

    NASA Technical Reports Server (NTRS)

    Zewari, Wahid; Lee, Kenneth Y.; Smith, David R.

    1999-01-01

    A comparison of space experiments with previous missions shows a common theme. Some of the recent experiments are based on the scientific fundamentals of instruments of prior years. However, the main distinguishing characteristic is the embodiment of advances in engineering and manufacturing in order to extract clearer and sharper images and extend the limits of measurement. One area of importance to future missions is providing vibration free observation platforms at acceptable costs. It has been shown by researchers that vibration problems cannot be eliminated by passive isolation techniques alone. Therefore, various organizations have conducted research in the area of combining active and passive vibration control techniques. The essence of this paper is to present progress in what is believed to be a new concept in this arena. It is based on the notion that if one active element in a vibration transmission path can provide a reasonable vibration attenuation, two active elements in series may provide more control options and better results. The paper presents the functions of a modular split shaft linear actuator developed by NASA's Goddard Space Flight Center and University of Massachusetts Lowell. It discusses some of the control possibilities facilitated by the device. Some preliminary findings and problems are also discussed.

  6. An equivalent method of mixed dielectric constant in passive microwave/millimeter radiometric measurement

    NASA Astrophysics Data System (ADS)

    Su, Jinlong; Tian, Yan; Hu, Fei; Gui, Liangqi; Cheng, Yayun; Peng, Xiaohui

    2017-10-01

    Dielectric constant is an important role to describe the properties of matter. This paper proposes This paper proposes the concept of mixed dielectric constant(MDC) in passive microwave radiometric measurement. In addition, a MDC inversion method is come up, Ratio of Angle-Polarization Difference(RAPD) is utilized in this method. The MDC of several materials are investigated using RAPD. Brightness temperatures(TBs) which calculated by MDC and original dielectric constant are compared. Random errors are added to the simulation to test the robustness of the algorithm. Keywords: Passive detection, microwave/millimeter, radiometric measurement, ratio of angle-polarization difference (RAPD), mixed dielectric constant (MDC), brightness temperatures, remote sensing, target recognition.

  7. Synergistic method for boreal soil moisture and soil freeze retrievals using active and passive microwave instruments

    NASA Astrophysics Data System (ADS)

    Smolander, Tuomo; Lemmetyinen, Juha; Rautiainen, Kimmo; Schwank, Mike; Pulliainen, Jouni

    2017-04-01

    Soil moisture and soil freezing are important for diverse hydrological, biogeochemical, and climatological applications. They affect surface energy balance, surface and subsurface water flow, and exchange rates of carbon with the atmosphere. Soil freezing controls important biogeochemical processes, like photosynthetic activity of plants and microbial activity within soils. Permafrost covers approximately 24% of the land surface in the Northern Hemisphere and seasonal freezing occurs on approximately 51% of the area. The retrieval method presented is based on an inversion technique and applies a semiempirical backscattering model that describes the dependence of radar backscattering of forest as a function of stem volume, soil permittivity, the extinction coefficient of forest canopy, surface roughness, incidence angle, and radar frequency. It gives an estimate of soil permittivity using active microwave measurements. Applying a Bayesian assimilation scheme, it is also possible to use other soil permittivity retrievals to regulate this estimate to combine for example low resolution passive observations with high resolution active observations for a synergistic retrieval. This way the higher variance in the active retrieval can be constricted with the passive retrieval when at the same time the spatial resolution of the product is improved compared to the passive-only retrieval. The retrieved soil permittivity estimate can be used to detect soil freeze/thaw state by considering the soil to be frozen when the estimate is below a threshold value. The permittivity retrieval can also be used to estimate the relative moisture of the soil. The method was tested using SAR (Synthetic Aperture Radar) measurements from ENVISAT ASAR instrument for the years 2010-2012 and from Sentinel-1 satellite for the years 2015-2016 in Sodankylä area in Northern Finland. The synergistic method was tested combining the SAR measurements with a SMOS (Soil Moisture Ocean Salinity) radiometer based retrieval. The results were validated using in situ measurements from automatic soil state observation stations in Sodankylä calibration and validation (CAL-VAL) site, which is a reference site for several EO (Earth Observation) data products.

  8. Performance of active and passive control of an airfoil using CPFD

    NASA Astrophysics Data System (ADS)

    Asselin, Daniel; Young, Jay; Williamson, C. H. K.

    2016-11-01

    Birds and fish employ flapping motions of their wings and fins in order to produce thrust and maneuver in flight and underwater. There is considerable interest in designing aerial and submersible systems that mimic these motions for the purposes of surveillance, environmental monitoring, and search and rescue, among other applications. Flapping motions are typically composed of combined pitch and heave and can provide good thrust and efficiency (Read, et al. 2003). In this study, we examine the performance of an airfoil actuated only in the heave direction. Using a cyber-physical fluid dynamics system (Mackowski & Williamson 2011, 2015, 2016), we simulate the presence of a torsion spring to enable the airfoil to undergo a passively controlled pitching motion. The addition of passive pitching combined with active heaving ("Active-Passive" or AP) provides significantly improved thrust and efficiency compared with heaving alone. In many cases, values of thrust and efficiency are comparable to or better than those obtained with two actively controlled degrees of freedom ("Active-Active" or AA). By using carefully-designed passive dynamics in the pitch direction, we can eliminate one of the two actuators, saving cost, complexity, and weight, while maintaining or improving performance. This work was supported by the Air Force Office of Scientific Research Grant No. FA9550-15-1-0243, monitored by Dr. Douglas Smith.

  9. Excessive motor overflow reveals abnormal inter-hemispheric connectivity in Friedreich ataxia.

    PubMed

    Low, Sze-Cheen; Corben, Louise A; Delatycki, Martin B; Ternes, Anne-Marie; Addamo, Patricia K; Georgiou-Karistianis, Nellie

    2013-07-01

    This study sought to characterise force variability and motor overflow in 12 individuals with Friedreich ataxia (FRDA) and 12 age- and gender-matched controls. Participants performed a finger-pressing task by exerting 30 and 70 % of their maximum finger force using the index finger of the right and left hand. Control of force production was measured as force variability, while any involuntary movements occurring on the finger of the other, passive hand, was measured as motor overflow. Significantly greater force variability in individuals with FRDA compared with controls is indicative of cortico-cerebellar disruption affecting motor control. Meanwhile, significantly greater motor overflow in this group provides the first evidence of possible abnormal inter-hemispheric activity that may be attributable to asymmetrical neuronal loss in the dentate nucleus. Overall, this study demonstrated a differential engagement in the underlying default processes of the motor system in FRDA.

  10. Passive vs. Active Control of Rhythmic Ball Bouncing: The Role of Visual Information

    ERIC Educational Resources Information Center

    Siegler, Isabelle A.; Bardy, Benoit G.; Warren, William H.

    2010-01-01

    The simple task of bouncing a ball on a racket offers a model system for studying how human actors exploit the physics and information of the environment to control their behavior. Previous work shows that people take advantage of a passively stable solution for ball bouncing but can also use perceptual information to actively stabilize bouncing.…

  11. Recovering Signals from Optical Fiber Interferometric Sensors

    DTIC Science & Technology

    1991-06-01

    GROUP SUB* GROUp Demodulation-, optical fiber, fi ber optic, sensors, passive -homodyne demodulation, symmetric demodul -ation, asymmetric demodulation...interferomeler without feedback control or modulation ofl th laser itself and without requiring the use of electronics withi -n the interferometer. One of...the 3x3 coupler permits Passive Homodyne Demodulation -of the phase-modulated signals provided by the interferometcr without feedback control or

  12. Powered ankle-foot prosthesis to assist level-ground and stair-descent gaits.

    PubMed

    Au, Samuel; Berniker, Max; Herr, Hugh

    2008-05-01

    The human ankle varies impedance and delivers net positive work during the stance period of walking. In contrast, commercially available ankle-foot prostheses are passive during stance, causing many clinical problems for transtibial amputees, including non-symmetric gait patterns, higher gait metabolism, and poorer shock absorption. In this investigation, we develop and evaluate a myoelectric-driven, finite state controller for a powered ankle-foot prosthesis that modulates both impedance and power output during stance. The system employs both sensory inputs measured local to the external prosthesis, and myoelectric inputs measured from residual limb muscles. Using local prosthetic sensing, we first develop two finite state controllers to produce biomimetic movement patterns for level-ground and stair-descent gaits. We then employ myoelectric signals as control commands to manage the transition between these finite state controllers. To transition from level-ground to stairs, the amputee flexes the gastrocnemius muscle, triggering the prosthetic ankle to plantar flex at terminal swing, and initiating the stair-descent state machine algorithm. To transition back to level-ground walking, the amputee flexes the tibialis anterior muscle, triggering the ankle to remain dorsiflexed at terminal swing, and initiating the level-ground state machine algorithm. As a preliminary evaluation of clinical efficacy, we test the device on a transtibial amputee with both the proposed controller and a conventional passive-elastic control. We find that the amputee can robustly transition between the finite state controllers through direct muscle activation, allowing rapid transitioning from level-ground to stair walking patterns. Additionally, we find that the proposed finite state controllers result in a more biomimetic ankle response, producing net propulsive work during level-ground walking and greater shock absorption during stair descent. The results of this study highlight the potential of prosthetic leg controllers that exploit neural signals to trigger terrain-appropriate, local prosthetic leg behaviors.

  13. Electrolyte and Electrode Passivation for Thin Film Batteries

    NASA Technical Reports Server (NTRS)

    West, W.; Whitacre, J.; Ratnakumar, B.; Brandon, E.; Blosiu, J.; Surampudi, S.

    2000-01-01

    Passivation films for thin film batteries have been prepared and the conductivity and voltage stability window have been measured. Thin films of Li2CO3 have a large voltage stability window of 4.8V, which facilitates the use of this film as a passivation at both the lithium anode-electrolyte interface at high cathodic potentials.

  14. Evaluation of recruitment methods for a trial targeting childhood obesity: Families for Health randomised controlled trial.

    PubMed

    Fleming, J; Kamal, A; Harrison, E; Hamborg, T; Stewart-Brown, S; Thorogood, M; Griffiths, F; Robertson, W

    2015-11-25

    Recruitment to trials evaluating the effectiveness of childhood obesity management interventions is challenging. We report our experience of recruitment to the Families for Health study, a randomised controlled trial evaluating the effectiveness of a family-based community programme for children aged 6-11 years, versus usual care. We evaluated the effectiveness of active recruitment (contacting eligible families directly) versus passive recruitment (informing the community through flyers, public events, media). Initial approaches included passive recruitment via the media (newspapers and radio) and two active recruitment methods: National Child Measurement Programme (letters to families with overweight children) and referrals from health-care professionals. With slow initial recruitment, further strategies were employed, including active (e.g. targeted letters from general practices) and passive (e.g. flyers, posters and public events) methods. At first enquiry from a potential participant, families were asked where they heard about the study. Further quantitative (questionnaire) and qualitative data (one-to-one interviews with parents/carers), were collected from recruited families at baseline and 3-month follow-up and included questions about recruitment. In total, 194 families enquired about Families for Health, and 115 (59.3 %) were recruited and randomised. Active recruitment yielded 85 enquiries, with 43 families recruited (50.6 %); passive recruitment yielded 99 enquiries with 72 families recruited (72.7 %). Information seen at schools or GP surgeries accounted for over a quarter of enquiries (28.4 %) and over a third (37.4 %) of final recruitment. Eight out of ten families who enquired this way were recruited. Media-led enquiries were low (5 %), but all were recruited. Children of families recruited actively were more likely to be Asian or mixed race. Despite extensive recruitment methods, the trial did not recruit as planned, and was awarded a no-cost extension to complete the 12-month follow-up. The higher number of participants recruited through passive methods may be due to the large number of potential participants these methods reached and because participants may see the information more than once. Recruiting to a child obesity treatment study is complex and it is advisable to use multiple recruitment strategies, some aiming at blanket coverage and some targeted at families with children who are overweight. Current Controlled Trials ISRCTN45032201 (Date: 18 August 2011).

  15. Transpleural ventilation of explanted human lungs

    PubMed Central

    Choong, Cliff K; Macklem, Peter T; Pierce, John A; Lefrak, Stephen S; Woods, Jason C; Conradi, Mark S; Yablonskiy, Dimitry A; Hogg, James C; Chino, Kimiaki; Cooper, Joel D

    2007-01-01

    Background The hypothesis that ventilation of emphysematous lungs would be enhanced by communication with the parenchyma through holes in the pleural surface was tested. Methods Fresh human lungs were obtained from patients with emphysema undergoing lung transplantation. Control human lungs were obtained from organ donors whose lungs, for technical reasons, were not considered suitable for implantation. Lungs were ventilated through the bronchial tree or transpleurally via a small hole communicating with the underlying parenchyma over which a flanged silicone tube had been cemented to the surface of the lung (spiracle). Measurements included flow‐volume‐time curves during passive deflation via each pathway; volume of trapped gas recovered from lungs via spiracles when no additional gas was obtainable passively from the airways; and magnetic resonance imaging assessment of spatial distribution of hyperpolarised helium (3He) administered through either the airways or spiracles. Results In emphysematous lungs, passively expelled volumes at 20 s were 94% greater through spiracles than via the airways. Following passive deflation from the airways, an average of 1.07 litres of trapped gas volume was recoverable via spiracles. Regions were ventilated by spiracles that were less well ventilated via bronchi. Conclusions Because of the extensive collateral ventilation present in emphysematous lungs, direct communication with the lung parenchyma through non‐anatomical pathways has the potential to improve the mechanics of breathing and hence ventilation. PMID:17412776

  16. Comparison of 2 Dosages of Stretching Treatment in Infants with Congenital Muscular Torticollis: A Randomized Trial.

    PubMed

    He, Lu; Yan, Xiaohua; Li, Jinling; Guan, Buyun; Ma, Liying; Chen, Ying; Mai, Jianning; Xu, Kaishou

    2017-05-01

    To compare the short-term efficacy of 2 dosages of stretching treatment on the clinical outcomes in infants with congenital muscular torticollis. This was a prospective randomized controlled study. Fifty infants with congenital muscular torticollis who were randomly assigned to 100-times stretching group and 50-times stretching group received stretching treatment for the affected sternocleidomastoid muscle. The outcomes including the head tilt, the cervical passive range of motion, and the muscle function of cervical lateral flexors determined by the muscle function scale were assessed at baseline and at 4 and 8 weeks after treatment. The sternocleidomastoid muscle growth analyzed by the thickness ratio of sternocleidomastoid muscles was measured using ultrasonography at baseline and 8 weeks after treatment. Except the ratio of muscle function scale scores, the postintervention outcomes were all significantly improved in both groups compared with baseline (P < 0.05). The 100-times stretching group showed greater improvement compared with 50-times stretching group in head tilt and cervical passive range of motion at 4 and 8 weeks after treatment (P < 0.05). Stretching treatment of 2 dosages may effectively improve head tilt, cervical passive range of motion, and sternocleidomastoid muscle growth in infants with congenital muscular torticollis. The stretching treatment of 100 times per day is likely to associate with greater improvement in head tilt and cervical passive range of motion.

  17. Prostate cancer survivors with a passive role preference in treatment decision-making are less satisfied with information received: Results from the PROFILES registry.

    PubMed

    Cuypers, Maarten; Lamers, Romy E D; de Vries, Marieke; Husson, Olga; Kil, Paul J M; van de Poll-Franse, Lonneke V

    2016-11-01

    To investigate decision-making role preferences and their association with the evaluation of information received in a sample of low-risk and intermediate-risk prostate cancer (Pca) survivors. Cross-sectional study involved 562 men diagnosed with low-risk or intermediate-risk Pca (median time since diagnosis, 48mo), measuring preferred decision-making role (Control Preference Scale) and the evaluation of information received (EORTC QLQ-INFO25). Analyses were performed using analysis of variance, chi-square tests, and multivariable linear regression models. Men who preferred a passive role were older and less educated than other preference groups and more often selected a noninvasive treatment option (all with P<0.001). The passive role preference group reported having received less information, judged the received information as less helpful, and indicated lower overall satisfaction with information received (all with P<0.05). Role preference groups did not differ in their desire to receive more information. Compared with nonpassive preference groups, the preference for a passive role in Pca treatment decision-making is associated with less satisfaction with the information received. Assessment of role preferences and tailored information provision could improve satisfaction with information received and perhaps may ultimately lead to improved patient participation in treatment decision-making. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Risk reduction in road and rail LPG transportation by passive fire protection.

    PubMed

    Paltrinieri, Nicola; Landucci, Gabriele; Molag, Menso; Bonvicini, Sarah; Spadoni, Gigliola; Cozzani, Valerio

    2009-08-15

    The potential reduction of risk in LPG (Liquefied Petroleum Gas) road transport due to the adoption of passive fire protections was investigated. Experimental data available for small scale vessels fully engulfed by a fire were extended to real scale road and rail tankers through a finite elements model. The results of mathematical simulations of real scale fire engulfment scenarios that may follow accidents involving LPG tankers proved the effectiveness of the thermal protections in preventing the "fired" BLEVE (Boiling Liquid Expanding Vapour Explosion) scenario. The presence of a thermal coating greatly increases the "time to failure", providing a time lapse that in the European experience may be considered sufficient to allow the start of effective mitigation actions by fire brigades. The results obtained were used to calculate the expected reduction of individual and societal risk due to LPG transportation in real case scenarios. The analysis confirmed that the introduction of passive fire protections turns out in a significant reduction of risk, up to an order of magnitude in the case of individual risk and of about 50% if the expectation value is considered. Thus, the adoption of passive fire protections, not compulsory in European regulations, may be an effective technical measure for risk reduction, and may contribute to achieve the control of "major accidents hazards" cited by the European legislation.

  19. [Interventions on the exposure of non-smoking pregnant women to passive smoking].

    PubMed

    Yao, Ting-ting; Chen, Xue-yun; Hu, De-wei; Mao, Zheng-zhong

    2008-09-01

    To investigate the extent of exposure of non-smoking pregnant women to passive smoking; to undertake interventions on the knowledge, attitudes and behaviors of those women toward passive smoking; and to evaluate the effectiveness of the interventions. A total of 128 non-smoking pregnant women participated in the survey. Their knowledge, attitudes and behaviors towards passive smoking were measured by a self-administered questionnaire. A sixteen-week intervention was undertaken. The knowledge and attitudes of the non-smoking pregnant women towards passive smoking improved significantly, as well as their attempts to avoid exposure to the passive smoking brought by their smoking husbands or other family members. Telephone counseling, booklets and doctors' advices were the most acceptable approaches of health education. The comprehensive interventions are effective for improving the knowledge, attitudes and behaviors of non-smoking women toward passive smoking.

  20. Effect of intermittent feedback control on robustness of human-like postural control system

    NASA Astrophysics Data System (ADS)

    Tanabe, Hiroko; Fujii, Keisuke; Suzuki, Yasuyuki; Kouzaki, Motoki

    2016-03-01

    Humans have to acquire postural robustness to maintain stability against internal and external perturbations. Human standing has been recently modelled using an intermittent feedback control. However, the causality inside of the closed-loop postural control system associated with the neural control strategy is still unknown. Here, we examined the effect of intermittent feedback control on postural robustness and of changes in active/passive components on joint coordinative structure. We implemented computer simulation of a quadruple inverted pendulum that is mechanically close to human tiptoe standing. We simulated three pairs of joint viscoelasticity and three choices of neural control strategies for each joint: intermittent, continuous, or passive control. We examined postural robustness for each parameter set by analysing the region of active feedback gain. We found intermittent control at the hip joint was necessary for model stabilisation and model parameters affected the robustness of the pendulum. Joint sways of the pendulum model were partially smaller than or similar to those of experimental data. In conclusion, intermittent feedback control was necessary for the stabilisation of the quadruple inverted pendulum. Also, postural robustness of human-like multi-link standing would be achieved by both passive joint viscoelasticity and neural joint control strategies.

Top