  1. Passive shut-down heat removal system

    DOEpatents

    Hundal, Rolv; Sharbaugh, John E.

    1988-01-01

    An improved shut-down heat removal system for a liquid metal nuclear reactor of the type having a vessel for holding hot and cold pools of liquid sodium is disclosed herein. Generally, the improved system comprises a redan or barrier within the reactor vessel which allows an auxiliary heat exchanger to become immersed in liquid sodium from the hot pool whenever the reactor pump fails to generate a metal-circulating pressure differential between the hot and cold pools of sodium. This redan also defines an alternative circulation path between the hot and cold pools of sodium in order to equilibrate the distribution of the decay heat from the reactor core. The invention may take the form of a redan or barrier that circumscribes the inner wall of the reactor vessel, thereby defining an annular space therebetween. In this embodiment, the bottom of the annular space communicates with the cold pool of sodium, and the auxiliary heat exchanger is placed in this annular space just above the drawn-down level that the liquid sodium assumes during normal operating conditions. Alternatively, the redan of the invention may include a pair of vertically oriented, concentrically disposed standpipes having a piston member disposed between them that operates somewhat like a pressure-sensitive valve. In both embodiments, the cessation of the pressure differential that is normally created by the reactor pump causes the auxiliary heat exchanger to be immersed in liquid sodium from the hot pool. Additionally, the redan in both embodiments forms a circulation flow path between the hot and cold pools so that the decay heat from the nuclear core is uniformly distributed within the vessel.

  2. Horizontal Heat Exchanger Design and Analysis for Passive Heat Removal Systems

    SciTech Connect

    Vierow, Karen

    2005-08-29

    This report describes a three-year project to investigate the major factors of horizontal heat exchanger performance in passive containment heat removal from a light water reactor following a design basis accident LOCA (Loss of Coolant Accident). The heat exchanger studied in this work may be used in advanced and innovative reactors, in which passive heat removal systems are adopted to improve safety and reliability The application of horizontal tube-bundle condensers to passive containment heat removal is new. In order to show the feasibility of horizontal heat exchangers for passive containment cooling, the following aspects were investigated: 1. the condensation heat transfer characteristics when the incoming fluid contains noncondensable gases 2. the effectiveness of condensate draining in the horizontal orientation 3. the conditions that may lead to unstable condenser operation or highly degraded performance 4. multi-tube behavior with the associated secondary-side effects This project consisted of two experimental investigations and analytical model development for incorporation into industry safety codes such as TRAC and RELAP. A physical understanding of the flow and heat transfer phenomena was obtained and reflected in the analysis models. Two gradute students (one funded by the program) and seven undergraduate students obtained research experience as a part of this program.

  3. Passive decay heat removal system for water-cooled nuclear reactors

    DOEpatents

    Forsberg, Charles W.

    1991-01-01

    A passive decay-heat removal system for a water-cooled nuclear reactor employs a closed heat transfer loop having heat-exchanging coils inside an open-topped, insulated box located inside the reactor vessel, below its normal water level, in communication with a condenser located outside of containment and exposed to the atmosphere. The heat transfer loop is located such that the evaporator is in a position where, when the water level drops in the reactor, it will become exposed to steam. Vapor produced in the evaporator passes upward to the condenser above the normal water level. In operation, condensation in the condenser removes heat from the system, and the condensed liquid is returned to the evaporator. The system is disposed such that during normal reactor operations where the water level is at its usual position, very little heat will be removed from the system, but during emergency, low water level conditions, substantial amounts of decay heat will be removed.

  4. Passive decay heat removal by natural air convection after severe accidents

    SciTech Connect

    Erbacher, F.J.; Neitzel, H.J.; Cheng, X.

    1995-09-01

    The composite containment proposed by the Research Center Karlsruhe and the Technical University Karlsruhe is to cope with severe accidents. It pursues the goal to restrict the consequences of core meltdown accidents to the reactor plant. One essential of this new containment concept is its potential to remove the decay heat by natural air convection and thermal radiation in a passive way. To investigate the coolability of such a passive cooling system and the physical phenomena involved, experimental investigations are carried out at the PASCO test facility. Additionally, numerical calculations are performed by using different codes. A satisfying agreement between experimental data and numerical results is obtained.

  5. BWR passive plant heat removal assessment (joint EPRI/CRIEPI advanced LWR studies)

    SciTech Connect

    Abdollahian, D.; Gillis, J.; Petrokas, R. , Inc., Campbell, CA )

    1991-03-01

    An independent assessment of the simplified boiling water reactor (SBWR) passive heat removal systems was performed. Information concerning required characteristics of the 600 MWe SBWR was gathered to form a basis for this assessment. Computerized models were then formulated to predict the operation of the gravity driven cooling system (GDCS), passive containment cooling system (PCCS), and the isolation condenser system. Investigation of the GDCS resulted in prediction of GDCS performance for a range of LOCAs and single failures. The ability of the GDCS to keep the core covered with a two phase mixture was determined. It was concluded that for all conditions which formed a basis for this study, the GDCS will keep the core covered and cooled. The evaluation of the PCCS showed that the containment will be cooled and that the system can operate in the presence of a significant amount of non-condensible gases. However, the PCCS will not be capable of reducing the containment pressure below approximately 40 psia. This is still significantly below the containment design pressure of 55 psig. Calculations performed to determine isolation condenser performance during reactor isolation events show that the isolation condensers remove enough decay heat to prevent the safety/relief valves from lifting. A study of the test program for the SBWR concluded that additional large scale tests may be needed to verify GDCS and PCCS performance. Finally, an investigation of larger power ratings showed that the passive systems are technically feasible for plant sizes of up to 1,000 MWe. 2 refs.

  6. Confirmatory analysis of the AP1000 passive residual heat removal heat exchanger with 3-D computational fluid dynamic analysis

    SciTech Connect

    Schwall, James R.; Karim, Naeem U.; Thakkar, Jivan G.; Taylor, Creed; Schulz, Terry; Wright, Richard F.

    2006-07-01

    The AP1000 is an 1100 MWe advanced nuclear power plant that uses passive safety features to enhance plant safety and to provide significant and measurable improvements in plant simplification, reliability, investment protection and plant costs. The AP1000 received final design approval from the US-NRC in 2004. The AP1000 design is based on the AP600 design that received final design approval in 1999. Wherever possible, the AP1000 plant configuration and layout was kept the same as AP600 to take advantage of the maturity of the design and to minimize new design efforts. As a result, the two-loop configuration was maintained for AP1000, and the containment vessel diameter was kept the same. It was determined that this significant power up-rate was well within the capability of the passive safety features, and that the safety margins for AP1000 were greater than those of operating PWRs. A key feature of the passive core cooling system is the passive residual heat removal heat exchanger (PRHR HX) that provides decay heat removal for postulated LOCA and non-LOCA events. The PRHR HX is a C-tube heat exchanger located in the in-containment refueling water storage tank (IRWST) above the core promoting natural circulation heat removal between the reactor cooling system and the tank. Component testing was performed for the AP600 PRHR HX to determine the heat transfer characteristics and to develop correlations to be used for the AP1000 safety analysis codes. The data from these tests were confirmed by subsequent integral tests at three separate facilities including the ROSA facility in Japan. Owing to the importance of this component, an independent analysis has been performed using the ATHOS-based computational fluid dynamics computer code PRHRCFD. Two separate models of the PRHR HX and IRWST have been developed representing the ROSA test geometry and the AP1000 plant geometry. Confirmation of the ROSA test results were used to validate PRHRCFD, and the AP1000 plant model

  7. Progress in the studies of passive heat removal in the next European torus under accident conditions

    SciTech Connect

    Soria, A. ); Renda, V.; Papa, L. . Joint Research Centre); Fenoglio, F. )

    1989-12-01

    Within the framework of safety analysis for the next European torus, a decay heat hazards assessment is under way in Ispra. Undercooling accidents (loss-of-coolant and loss-of-flow accidents (LOCAs and LOFAs)) due to pump failure have been investigated assuming an automatic plasma shutdown in both cases. The passive heat removal mechanisms considered include radiation between components and residual cooling by the thermosyphon effect in the main cooling circuits. Conservative thermohydraulic calculations have been made to determine coolant velocity and temperature transients to avoid water boiling int he circuits. Results show that during a LOFA, water boiling can be avoided provided that the water inertia is large enough, and material melting temperatures are not reached during a LOCA.

  8. Study on natural convection capability of liquid gallium for passive decay heat removal system (PDHRS)

    SciTech Connect

    Kang, S.; Ha, K. S.; Lee, S. W.; Park, S. D.; Kim, S. M.; Seo, H.; Kim, J. H.; Bang, I. C.

    2012-07-01

    The safety issues of the SFRs are important due to the fact that it uses sodium as a nuclear coolant, reacting vigorously with water and air. For that reason, there are efforts to seek for alternative candidates of liquid metal coolants having excellent heat transfer property and to adopt improved safety features to the SFR concepts. This study considers gallium as alternative liquid metal coolant applicable to safety features in terms of chemical activity issue of the sodium and aims to experimentally investigate the natural convection capability of gallium as a feasibility study for the development of gallium-based passive safety features in SFRs. In this paper, the design and construction of the liquid gallium natural convection loop were carried out. The experimental results of heat transfer coefficient of liquid gallium resulting in heat removal {approx}2.53 kW were compared with existing correlations and they were much lower than the correlations. To comparison of the experimental data with computer code analysis, gallium property code was developed for employing MARS-LMR (Korea version of RELAP) based on liquid gallium as working fluid. (authors)

  9. Passive solar heating

    NASA Astrophysics Data System (ADS)

    Claridge, David E.; Mowris, Robert J.

    1985-11-01

    Buildings have been designed to use solar gains for winter heating for several millenia, but the quantitative basis for passive solar design has only been developed in the last decade. A simplified lumped capacitance model is used to provide insight into the physics of passive building behavior. Three passive design methods are described: the Solar Load Ratio (SLR) method based on correlations to simulation results; the Gordon/Zarmi closed form analytical mode;; and the ``unutilizability'' model of Monsen and Klein. Model predictions are compared with measured results; agreement is good if measured building characteristics are used. Numerous passive houses use less than 2 Btu/ft2-DD for auxiliary heating and consensus is developing that modest levels of passive glazing combined with superinsulation techniques can provide the best feature of both approaches.

  10. COMBINED ACTIVE/PASSIVE DECAY HEAT REMOVAL APPROACH FOR THE 24 MWt GAS-COOLED FAST REACTOR

    SciTech Connect

    CHENG,L.Y.; LUDEWIG, H.

    2007-06-01

    Decay heat removal at depressurized shutdown conditions has been regarded as one of the key areas where significant improvement in passive response was targeted for the GEN IV GFR over the GCFR designs of thirty years ago. It has been recognized that the poor heat transfer characteristics of gas coolant at lower pressures needed to be accommodated in the GEN IV design. The design envelope has therefore been extended to include a station blackout sequence simultaneous with a small break/leak. After an exploratory phase of scoping analysis in this project, together with CEA of France, it was decided that natural convection would be selected as the passive decay heat removal approach of preference. Furthermore, a double vessel/containment option, similar to the double vessel/guard vessel approach of the SFR, was selected as the means of design implementation to reduce the PRA risks of the depressurization accident. However additional calculations in conjunction with CEA showed that there was an economic penalty in terms of decay heat removal system heat exchanger size, elevation heights for thermal centers, and most of all in guard containment back pressure for complete reliance on natural convection only. The back pressure ranges complicated the design requirements for the guard containment. Recognizing that the definition of a loss-of-coolant-accident in the GFR is a misnomer, since gas coolant will always be present, and the availability of some driven blower would reduce fuel temperature transients significantly; it was decided instead to aim for a hybrid active/passive combination approach to the selected BDBA. Complete natural convection only would still be relied on for decay heat removal but only after the first twenty four hours after the initiation of the accident. During the first twenty four hour period an actively powered blower would be relied on to provide the emergency decay power removal. However the power requirements of the active blower

  11. Passive Vaporizing Heat Sink

    NASA Technical Reports Server (NTRS)

    Knowles, TImothy R.; Ashford, Victor A.; Carpenter, Michael G.; Bier, Thomas M.

    2011-01-01

    A passive vaporizing heat sink has been developed as a relatively lightweight, compact alternative to related prior heat sinks based, variously, on evaporation of sprayed liquids or on sublimation of solids. This heat sink is designed for short-term dissipation of a large amount of heat and was originally intended for use in regulating the temperature of spacecraft equipment during launch or re-entry. It could also be useful in a terrestrial setting in which there is a requirement for a lightweight, compact means of short-term cooling. This heat sink includes a hermetic package closed with a pressure-relief valve and containing an expendable and rechargeable coolant liquid (e.g., water) and a conductive carbon-fiber wick. The vapor of the liquid escapes when the temperature exceeds the boiling point corresponding to the vapor pressure determined by the setting of the pressure-relief valve. The great advantage of this heat sink over a melting-paraffin or similar phase-change heat sink of equal capacity is that by virtue of the =10x greater latent heat of vaporization, a coolant-liquid volume equal to =1/10 of the paraffin volume can suffice.

  12. Gap between active and passive solar heating

    SciTech Connect

    Balcomb, J.D.

    1985-01-01

    The gap between active and passive solar could hardly be wider. The reasons for this are discussed and advantages to narrowing the gap are analyzed. Ten years of experience in both active and passive systems are reviewed, including costs, frequent problems, performance prediction, performance modeling, monitoring, and cooling concerns. Trends are analyzed, both for solar space heating and for service water heating. A tendency for the active and passive technologies to be converging is observed. Several recommendations for narrowing the gap are presented.

  13. Passive heat transfer means for nuclear reactors

    DOEpatents

    Burelbach, James P.

    1984-01-01

    An improved passive cooling arrangement is disclosed for maintaining adjacent or related components of a nuclear reactor within specified temperature differences. Specifically, heat pipes are operatively interposed between the components, with the vaporizing section of the heat pipe proximate the hot component operable to cool it and the primary condensing section of the heat pipe proximate the other and cooler component operable to heat it. Each heat pipe further has a secondary condensing section that is located outwardly beyond the reactor confinement and in a secondary heat sink, such as air ambient the containment, that is cooler than the other reactor component. Means such as shrouding normally isolated the secondary condensing section from effective heat transfer with the heat sink, but a sensor responds to overheat conditions of the reactor to open the shrouding, which thereby increases the cooling capacity of the heat pipe. By having many such heat pipes, an emergency passive cooling system is defined that is operative without electrical power.

  14. Passive ice freezing-releasing heat pipe

    DOEpatents

    Gorski, Anthony J.; Schertz, William W.

    1982-01-01

    A heat pipe device has been developed which permits completely passive ice formation and periodic release of ice without requiring the ambient temperature to rise above the melting point of water. This passive design enables the maximum amount of cooling capacity to be stored in the tank.

  15. Apparatus for passive removal of subsurface contaminants

    DOEpatents

    Pemberton, Bradley E.; May, Christopher P.; Rossabi, Joseph

    1997-01-01

    An apparatus is provided which passively removes contaminated gases from a subsurface. The apparatus includes a riser pipe extending into a subsurface which has an exterior end in fluid communication with a valve. When well pressure is greater than atmospheric pressure, the valve opens to release contaminants into the atmosphere, and when well pressure is less than atmospheric pressure, the valve closes to prevent flow of air into the well. The valve assembly of the invention comprises a lightweight ball which is lifted from its valve seat with a slight pressure drop between the well and the atmosphere.

  16. Apparatus for passive removal of subsurface contaminants

    DOEpatents

    Pemberton, B.E.; May, C.P.; Rossabi, J.

    1997-06-24

    An apparatus is provided which passively removes contaminated gases from a subsurface. The apparatus includes a riser pipe extending into a subsurface which has an exterior end in fluid communication with a valve. When well pressure is greater than atmospheric pressure, the valve opens to release contaminants into the atmosphere, and when well pressure is less than atmospheric pressure, the valve closes to prevent flow of air into the well. The valve assembly of the invention comprises a lightweight ball which is lifted from its valve seat with a slight pressure drop between the well and the atmosphere. 7 figs.

  17. Integrated bias removal in passive radar systems

    NASA Astrophysics Data System (ADS)

    Subramaniam, M.; Punithakumar, K.; McDonald, M.; Kirubarajan, T.

    2008-04-01

    A passive coherent location (PCL) system exploits the ambient FM radio or television signals from powerful local transmitters, which makes it ideal for covert tracking. In a passive radar system, also known as PCL system, a variety of measurements can be used to estimate target states such as direction of arrival (DOA), time difference of arrival (TDOA) or Doppler shift. Noise and the precision of DOA estimation are main issues in a PCL system and methods such as conventional beam forming (CBF) algorithm, algebraic constant modulus algorithm (ACMA) are widely analyzed in literature to address them. In practical systems, although it is necessary to reduce the directional ambiguities, the placement of receivers closed to each other results in larger bias in the estimation of DOA of signals, especially when the targets move off bore-sight. This phenomenon leads to degradation in the performance of the tracking algorithm. In this paper, we present a method for removing the bias in DOA to alleviate the aforementioned problem. The simulation results are presented to show the effectiveness of the proposed algorithm with an example of tracking airborne targets.

  18. Passive heating of the ground surface

    NASA Astrophysics Data System (ADS)

    Tyburczyk, Anna

    2016-03-01

    The phenomenon of phase change is one of the most important contemporary issues of thermal engineering. In particular, this applies to all kinds of heat exchanger systems, which should achieve the highest possible efficiency while reducing investment and operating costs. Some of these systems are heat pipes or thermosyphons, which, among others, are used for the heat transfer, temperature stabilization and the regulation of heat flux density. Additionally, they are passive systems, and therefore do not require an external power supply. Heat pipes can be used to stabilize the surface temperature of roads and driveways. Large heat tubes can be applied for heating the surface of bridges and overpasses, which become icy in unfavorable climatic conditions. The paper presents research on the test facility, whose main component is a long vertical copper fin. The temperature at the base of the fin was kept constant for a given series of measurements. Heat receiving fluid was ethanol at atmospheric pressure. The measurement methodology and the results of investigations were discussed. The surface temperature distribution was measured with the infrared camera, and on this basis the local values of heat flow and the heat transfer coefficient were determined. The results were presented as boiling curves for both the fin with the smooth surface and the one covered with a metal capillary-porous structure. The results obtained are useful in the design of heat exchangers, including passive heating of the ground.

  19. Carbon Dioxide Removal via Passive Thermal Approaches

    NASA Technical Reports Server (NTRS)

    Lawson, Michael; Hanford, Anthony; Conger, Bruce; Anderson, Molly

    2011-01-01

    A paper describes a regenerable approach to separate carbon dioxide from other cabin gases by means of cooling until the carbon dioxide forms carbon dioxide ice on the walls of the physical device. Currently, NASA space vehicles remove carbon dioxide by reaction with lithium hydroxide (LiOH) or by adsorption to an amine, a zeolite, or other sorbent. Use of lithium hydroxide, though reliable and well-understood, requires significant mass for all but the shortest missions in the form of lithium hydroxide pellets, because the reaction of carbon dioxide with lithium hydroxide is essentially irreversible. This approach is regenerable, uses less power than other historical approaches, and it is almost entirely passive, so it is more economical to operate and potentially maintenance- free for long-duration missions. In carbon dioxide removal mode, this approach passes a bone-dry stream of crew cabin atmospheric gas through a metal channel in thermal contact with a radiator. The radiator is pointed to reject thermal loads only to space. Within the channel, the working stream is cooled to the sublimation temperature of carbon dioxide at the prevailing cabin pressure, leading to formation of carbon dioxide ice on the channel walls. After a prescribed time or accumulation of carbon dioxide ice, for regeneration of the device, the channel is closed off from the crew cabin and the carbon dioxide ice is sublimed and either vented to the environment or accumulated for recovery of oxygen in a fully regenerative life support system.

  20. Experimental Breeder Reactor II inherent shutdown and heat removal tests - test results and analysis

    SciTech Connect

    Planchon, H.P.; Singer, R.M.; Mohr, D.; Feldman, E.E.; Chang, L.K.; Betten, P.R.

    1985-01-01

    A test program is being conducted to demonstrate that a power producing Liquid Metal Reactor (LMR) can passively remove shutdown heat by natural convection; passively reduce power in response to a loss of reactor flow and passively reduce power in response to a loss of the balance of plant heat sink. Measurements and pretest predictions confirm that natural convection is a reliable, predictable method of shutdown heat removal and suggest that safety-related pumps or pony motors are not necessary for safe, shutdown heat removal in a LMR. Measurements from tests in which reactor flow and heat rejection to the balance of plant were perturbed show that reactivity feedbacks can passively control power and temperature. This data is a basis for additional tests including a complete loss-of-flow without scram and a complete loss of heat sink without scram.

  1. Passive ice freezing-releasing heat pipe. [Patent application

    DOEpatents

    Gorski, A.J.; Schertz, W.W.

    1980-09-29

    A heat pipe device has been developed which permits completely passive ice formation and periodic release of ice without requiring the ambient temperature to rise above the melting point of water. This passive design enables the maximum amount of cooling capacity to be stored in the tank.

  2. Heating Unsaturated Sediments Using Solar Energy to Enhance Passive Sediment Remediation Technologies

    NASA Astrophysics Data System (ADS)

    Rossman, A.

    2002-12-01

    Sediment heating has been shown to enhance passive sediment remediation technologies such as bioremediation and barometric pumping (passive soil venting). Sediment heating raises the slow remediation rates that often limit the widespread use of these technologies. In bioremediation applications, a 10 degree C increase in subsurface temperature is expected to double the microbial activity, and thus the remediation rate. The removal rate of tetracholorethylene (PCE - a common subsurface contaminant) by passive soil vapor extraction is expected to nearly double in low-permeable sediments when the subsurface is heated 10 degree C from ambient temperatures due to an increased vapor pressure in the PCE. When the sediment is heated using renewable energy sources, these thermally enhanced remediation technologies can be environmentally benign alternatives to conventional remediation techniques that rely on large external energy inputs. The thermally enhanced passive technologies may be particularly useful for remediating unsaturated, low-permeable lenses that are troublesome to most conventional remediation technologies such as conventional soil vapor extraction and co-solvent flushes. The main objective of this work was to quantify subsurface sediment heating using a solar powered heat injection well. To do this, a pilot sediment heating system was installed in Vermont and high resolution meteorological and sediment temperature data were collected using a stand-alone data acquisition system. Unsaturated, silty sediments were heated in-situ by converting the direct and indirect solar energy available at the surface to heat energy in the subsurface using stand-alone renewable energy sources and a resistive element heat injection well. The heat injection well was powered by a 600-W passively tracking photovoltaic (PV) array and a small 1.2-m swept area wind turbine. It is envisioned that the heat injection well would be placed directly into an area of high subsurface

  3. Passive heat-transfer means for nuclear reactors. [LMFBR

    DOEpatents

    Burelbach, J.P.

    1982-06-10

    An improved passive cooling arrangement is disclosed for maintaining adjacent or related components of a nuclear reactor within specified temperature differences. Specifically, heat pipes are operatively interposed between the components, with the vaporizing section of the heat pipe proximate the hot component operable to cool it and the primary condensing section of the heat pipe proximate the other and cooler component operable to heat it. Each heat pipe further has a secondary condensing section that is located outwardly beyond the reactor confinement and in a secondary heat sink, such as air ambient the containment, that is cooler than the other reactor component. By having many such heat pipes, an emergency passive cooling system is defined that is operative without electrical power.

  4. Position paper -- Waste storage tank heat removal

    SciTech Connect

    Stine, M.D.

    1995-01-03

    The purpose of this paper is to develop and document a position on the heat removal system to be used on the waste storage tanks currently being designed for the Multi-Function Waste Tank Facility (MWTF), project W-236A. The current preliminary design for the waste storage primary tank heat removal system consists of the following subsystems: (1) a once-through dome space ventilation system; (2) a recirculation dome space ventilation system; and (3) an annulus ventilation system. Recently completed and ongoing studies have evaluated alternative heat removal systems in an attempt to reduce system costs and to optimize heat removal capabilities. In addition, a thermal/heat transfer analysis is being performed that will provide assurance that the heat removal systems selected will be capable of removing the total primary tank design heat load of 1.25 MBtu/hr at an allowable operating temperature of 190 F. Although 200 F is the design temperature limit, 190 F has been selected as the maximum allowable operating temperature limit based on instrumentation sensitivity, instrumentation location sensitivity, and other factors. Seven options are discussed and recommendations are made.

  5. Heat exchanger with a removable tube section

    DOEpatents

    Wolowodiuk, W.; Anelli, J.

    1975-07-29

    A heat exchanger is described in which the tube sheet is secured against primary liquid pressure, but which allows for easy removal of the tube section. The tube section is supported by a flange which is secured by a number of shear blocks, each of which extends into a slot which is immovable with respect to the outer shell of the heat exchanger. (auth)

  6. Human cardiovascular responses to passive heat stress.

    PubMed

    Crandall, Craig G; Wilson, Thad E

    2015-01-01

    Heat stress increases human morbidity and mortality compared to normothermic conditions. Many occupations, disease states, as well as stages of life are especially vulnerable to the stress imposed on the cardiovascular system during exposure to hot ambient conditions. This review focuses on the cardiovascular responses to heat stress that are necessary for heat dissipation. To accomplish this regulatory feat requires complex autonomic nervous system control of the heart and various vascular beds. For example, during heat stress cardiac output increases up to twofold, by increases in heart rate and an active maintenance of stroke volume via increases in inotropy in the presence of decreases in cardiac preload. Baroreflexes retain the ability to regulate blood pressure in many, but not all, heat stress conditions. Central hypovolemia is another cardiovascular challenge brought about by heat stress, which if added to a subsequent central volumetric stress, such as hemorrhage, can be problematic and potentially dangerous, as syncope and cardiovascular collapse may ensue. These combined stresses can compromise blood flow and oxygenation to important tissues such as the brain. It is notable that this compromised condition can occur at cardiac outputs that are adequate during normothermic conditions but are inadequate in heat because of the increased systemic vascular conductance associated with cutaneous vasodilation. Understanding the mechanisms within this complex regulatory system will allow for the development of treatment recommendations and countermeasures to reduce risks during the ever-increasing frequency of severe heat events that are predicted to occur.

  7. Human Cardiovascular Responses to Passive Heat Stress

    PubMed Central

    Crandall, Craig G.; Wilson, Thad E.

    2016-01-01

    Heat stress increases human morbidity and mortality compared to normothermic conditions. Many occupations, disease states, as well as stages of life are especially vulnerable to the stress imposed on the cardiovascular system during exposure to hot ambient conditions. This review focuses on the cardiovascular responses to heat stress that are necessary for heat dissipation. To accomplish this regulatory feat requires complex autonomic nervous system control of the heart and various vascular beds. For example, during heat stress cardiac output increases up to twofold, by increases in heart rate and an active maintenance of stroke volume via increases in inotropy in the presence of decreases in cardiac preload. Baroreflexes retain the ability to regulate blood pressure in many, but not all, heat stress conditions. Central hypovolemia is another cardiovascular challenge brought about by heat stress, which if added to a subsequent central volumetric stress, such as hemorrhage, can be problematic and potentially dangerous, as syncope and cardiovascular collapse may ensue. These combined stresses can compromise blood flow and oxygenation to important tissues such as the brain. It is notable that this compromised condition can occur at cardiac outputs that are adequate during normothermic conditions but are inadequate in heat because of the increased systemic vascular conductance associated with cutaneous vasodilation. Understanding the mechanisms within this complex regulatory system will allow for the development of treatment recommendations and countermeasures to reduce risks during the ever-increasing frequency of severe heat events that are predicted to occur. PMID:25589263

  8. Passive gas-gap heat switch for adiabatic demagnetization refrigerator

    NASA Technical Reports Server (NTRS)

    Shirron, Peter J. (Inventor); Di Pirro, Michael J. (Inventor)

    2005-01-01

    A passive gas-gap heat switch for use with a multi-stage continuous adiabatic demagnetization refrigerator (ADR). The passive gas-gap heat switch turns on automatically when the temperature of either side of the switch rises above a threshold value and turns off when the temperature on either side of the switch falls below this threshold value. One of the heat switches in this multistage process must be conductive in the 0.25? K to 0.3? K range. All of the heat switches must be capable of switching off in a short period of time (1-2 minutes), and when off to have a very low thermal conductance. This arrangement allows cyclic cooling cycles to be used without the need for separate heat switch controls.

  9. Development of Passive Fuel Cell Thermal Management Heat Exchanger

    NASA Technical Reports Server (NTRS)

    Burke, Kenneth A.; Jakupca, Ian J.; Colozza, Anthony J.

    2010-01-01

    The NASA Glenn Research Center is developing advanced passive thermal management technology to reduce the mass and improve the reliability of space fuel cell systems for the NASA Exploration program. The passive thermal management system relies on heat conduction within highly thermally conductive cooling plates to move the heat from the central portion of the cell stack out to the edges of the fuel cell stack. Using the passive approach eliminates the need for a coolant pump and other cooling loop components within the fuel cell system which reduces mass and improves overall system reliability. Previous development demonstrated the performance of suitable highly thermally conductive cooling plates that could conduct the heat, provide a sufficiently uniform temperature heat sink for each cell of the fuel cell stack, and be substantially lighter than the conventional thermal management approach. Tests were run with different materials to evaluate the design approach to a heat exchanger that could interface with the edges of the passive cooling plates. Measurements were made during fuel cell operation to determine the temperature of individual cooling plates and also to determine the temperature uniformity from one cooling plate to another.

  10. Passive thermosyphon solar heating and cooling module with supplementary heating

    NASA Technical Reports Server (NTRS)

    1977-01-01

    A collection of three quarterly reports from Sigma Research, Inc., covering progress and status from January through September 1977 are presented. Three heat exchangers are developed for use in a solar heating and cooling system for installation into single-family dwellings. Each exchanger consists of one heating and cooling module and one submerged electric water heating element.

  11. Entirely passive heat pipe apparatus capable of operating against gravity

    DOEpatents

    Koenig, Daniel R.

    1982-01-01

    The disclosure is directed to an entirely passive heat pipe apparatus capable of operating against gravity for vertical distances in the order of 3 to 7 meters and more. A return conduit into which an inert gas is introduced is used to lower the specific density of the working fluid so that it may be returned a greater vertical distance from condenser to evaporator.

  12. Passive vapor transport solar heating systems

    SciTech Connect

    Hedstrom, J.C.; Neeper, D.A.

    1985-01-01

    In the systems under consideration, refrigerant is evaporated in a solar collector and condensed in thermal storage for space or water heating located within the building at a level below that of the collector. Condensed liquid is lifted to an accumulator above the collector by the vapor pressure generated in the collector. Tests of two systems are described, and it is concluded that one of these systems offers distinct advantages.

  13. Heat treatment of exchangers to remove coke

    SciTech Connect

    Turner, J.D.

    1990-02-20

    This patent describes a process for preparing furfural coke for removal from metallic surfaces. It comprises: heating the furfural coke without causing an evolution of heat capable of undesirably altering metallurgical properties of the surfaces in the presence of a gas containing molecular oxygen at a sufficient temperature below 800{degrees}F (427{degrees}C) for a sufficient time to change the crush strength of the coke so as to permit removal with a water jet at a pressure of five thousand pounds per square inch.

  14. Emergency Decay Heat Removal in a GEN-IV Gas-Cooled Fast Reactor

    SciTech Connect

    Cheng, Lap Y.; Ludewig, Hans; Jo, Jae

    2006-07-01

    A series of transient analyses using the system code RELAP5-3d has been performed to confirm the efficacy of a proposed hybrid active/passive combination approach to the decay heat removal for an advanced 2400 MWt GEN-IV gas-cooled fast reactor. The accident sequence of interest is a station blackout simultaneous with a small break (10 sq.inch/0.645 m{sup 2}) in the reactor vessel. The analyses cover the three phases of decay heat removal in a depressurization accident: (1) forced flow cooling by the power conversion unit (PCU) coast down, (2) active forced flow cooling by a battery powered blower, and (3) passive cooling by natural circulation. The blower is part of an emergency cooling system (ECS) that by design is to sustain passive decay heat removal via natural circulation cooling 24 hours after shutdown. The RELAP5 model includes the helium-cooled reactor, the ECS (primary and secondary side), the PCU with all the rotating machinery (turbine and compressors) and the heat transfer components (recuperator, pre-cooler and inter-cooler), and the guard containment that surrounds the reactor and the PCU. The transient analysis has demonstrated the effectiveness of passive decay heat removal by natural circulation cooling when the guard containment pressure is maintained at or above 800 kPa. (authors)

  15. Incremental cooling load determination for passive direct gain heating systems

    NASA Astrophysics Data System (ADS)

    Sullivan, P. W.; Mahone, D.; Fuller, W.; Gruber, J.; Kammerud, R.; Place, W.; Anderson, B.

    1981-05-01

    The applicability of the National Association of Home Builders (NAHB) full load compressor hour method for predicting the cooling load increase in a residence attributable to direct gain passive heating systems is examined. The NAHB method predictions are compared with the results of 200 hour-by-hour simulations using BLAST, and the two methods show reasonable agreement. The degree of agreement and the limitations of the NAHB method are discussed.

  16. The Gas-Cooled Fast Reactor: Report on Safety System Design for Decay Heat Removal

    SciTech Connect

    K. D. Weaver; T. Marshall; T. Y. C. Wei; E. E. Feldman; M. J. Driscoll; H. Ludewig

    2003-09-01

    The gas-cooled fast reactor (GFR) was chosen as one of the Generation IV nuclear reactor systems to be developed based on its excellent potential for sustainability through reduction of the volume and radiotoxicity of both its own fuel and other spent nuclear fuel, and for extending/utilizing uranium resources orders of magnitude beyond what the current open fuel cycle can realize. In addition, energy conversion at high thermal efficiency is possible with the current designs being considered, thus increasing the economic benefit of the GFR. However, research and development challenges include the ability to use passive decay heat removal systems during accident conditions, survivability of fuels and in-core materials under extreme temperatures and radiation, and economical and efficient fuel cycle processes. This report addresses/discusses the decay heat removal options available to the GFR, and the current solutions. While it is possible to design a GFR with complete passive safety (i.e., reliance solely on conductive and radiative heat transfer for decay heat removal), it has been shown that the low power density results in unacceptable fuel cycle costs for the GFR. However, increasing power density results in higher decay heat rates, and the attendant temperature increase in the fuel and core. Use of active movers, or blowers/fans, is possible during accident conditions, which only requires 3% of nominal flow to remove the decay heat. Unfortunately, this requires reliance on active systems. In order to incorporate passive systems, innovative designs have been studied, and a mix of passive and active systems appears to meet the requirements for decay heat removal during accident conditions.

  17. Solar passive ceiling system. Final report. [Passive solar heating system with venetian blind reflectors and latent heat storage in ceiling

    SciTech Connect

    Schneider, A.R.

    1980-01-01

    The construction of a 1200 square foot building, with full basement, built to be used as a branch library in a rural area is described. The primary heating source is a passive solar system consisting of a south facing window system. The system consists of: a set of windows located in the south facing wall only, composed of double glazed units; a set of reflectors mounted in each window which reflects sunlight up to the ceiling (the reflectors are similar to venetian blinds); a storage area in the ceiling which absorbs the heat from the reflected sunlight and stores it in foil salt pouches laid in the ceiling; and an automated curtain which automatically covers and uncovers the south facing window system. The system is totally passive and uses no blowers, pumps or other active types of heat distribution equipment. The building contains a basement which is normally not heated, and the north facing wall is bermed four feet high around the north side.

  18. Sympathetic activity during passive heat stress in healthy aged humans

    PubMed Central

    Gagnon, Daniel; Schlader, Zachary J; Crandall, Craig G

    2015-01-01

    Abstract Cardiovascular adjustments during heat stress are generally attenuated in healthy aged humans, which could be due to lower increases in sympathetic activity compared to the young. We compared muscle sympathetic nerve activity (MSNA) between 11 young (Y: 28 ± 4 years) and 10 aged (A: 70 ± 5 years) subjects prior to and during passive heating. Furthermore, MSNA responses were compared when a cold pressor test (CPT) and lower body negative pressure (LBNP) were superimposed upon heating. Baseline MSNA burst frequency (Y: 15 ± 4 vs. A: 31 ± 3 bursts min−1, P ≤ 0.01) and burst incidence (Y: 26 ± 8 vs. A: 50 ± 7 bursts (100 cardiac cycles (CC))−1, P ≤ 0.01) were greater in the aged. Heat stress increased core temperature to a similar extent in both groups (Y: +1.2 ± 0.1 vs. A: +1.2 ± 0.0°C, P = 0.99). Absolute levels of MSNA remained greater in the aged during heat stress (burst frequency: Y: 47 ± 6 vs. A: 63 ± 11 bursts min−1, P ≤ 0.01; burst incidence: Y: 48 ± 8 vs. A: 67 ± 9 bursts (100 CC)−1, P ≤ 0.01); however, the increase in both variables was similar between groups (both P ≥ 0.1). The CPT and LBNP further increased MSNA burst frequency and burst incidence, although the magnitude of increase was similar between groups (both P ≥ 0.07). These results suggest that increases in sympathetic activity during heat stress are not attenuated in healthy aged humans. Key points Cardiovascular adjustments to heat stress are attenuated in healthy aged individuals, which could contribute to their greater prevalence of heat-related illnesses and deaths during heat waves. The attenuated cardiovascular adjustments in the aged could be due to lower increases in sympathetic nerve activity during heat stress. We examined muscle sympathetic nerve activity (MSNA) and plasma catecholamine concentrations in healthy young and aged individuals during whole-body passive heat stress. The main finding

  19. Optimization of storage in passive solar heating systems. Final report

    SciTech Connect

    Bahm, R.J.

    1980-05-01

    The search for a simple method of estimating the optimum amount of storage for passive solar space heating system designs and the results of that search are described. The project goals, and why the project is important are described. The major project results are presented in the order of their importance with respect to meeting the project goal. A narrative description of the project is given. Here the various approaches attempted are described, giving the reasons for failure in those areas that were not successful. The Appendices contain the bulk of data generated by this project. Most of the data is presented in graphical form. (MHR)

  20. Condensate removal device for heat exchanger

    NASA Technical Reports Server (NTRS)

    Trusch, R. B.; Oconnor, E. W. (Inventor)

    1975-01-01

    A set of perforated tubes disposed at the gas output side of a heat exchanger, in a position not to affect the rate of flow of the air or other gas is described. The tubes are connected to a common manifold which is connected to a sucking device. Where it is necessary to conserve and recirculate the air sucked through the tubes, the output of the manifold is run through a separator to remove the condensate from the gas. The perforations in the slurper tubes are small, lying in the range of 0.010 inch to 0.100 inch. The tubes are disposed in contact with the surfaces of the heat exchanger on which the condensate is precipitated, whether fins or plates, so that the water may be directed to the tube openings by means of surface effects, together with the assistance of the air flow. Only about 5 percent of the air output need be thus diverted, and it effectively removes virtually all of the condensate.

  1. Germanium oxide removal by citric acid and thiol passivation from citric acid-terminated Ge(100).

    PubMed

    Collins, Gillian; Aureau, Damien; Holmes, Justin D; Etcheberry, Arnaud; O'Dwyer, Colm

    2014-12-01

    Many applications of germanium (Ge) are underpinned by effective oxide removal and surface passivation. This important surface treatment step often requires H-X (X = Cl, Br, I) or HF etchants. Here, we show that aqueous citric acid solutions are effective in the removal of GeOx. The stability of citric acid-treated Ge(100) is compared to HF and HCl treated surfaces and analyzed by X-ray photoelectron spectroscopy. Further Ge surface passivation was investigated by thiolation using alkane monothiols and dithiols. The organic passivation layers show good stability with no oxide regrowth observed after 3 days of ambient exposure.

  2. Wallboard with Latent Heat Storage for Passive Solar Applications

    SciTech Connect

    Kedl, R.J.

    2001-05-31

    Conventional wallboard impregnated with octadecane paraffin [melting point-23 C (73.5 F)] is being developed as a building material with latent heat storage for passive solar and other applications. Impregnation was accomplished simply by soaking the wallboard in molten wax. Concentrations of wax in the combined product as high as 35% by weight can be achieved. Scale-up of the soaking process, from small laboratory samples to full-sized 4- by 8-ft sheets, has been successfully accomplished. The required construction properties of wallboard are maintained after impregnation, that is, it can be painted and spackled. Long-term, high-temperature exposure tests and thermal cycling tests showed no tendency of the paraffin to migrate within the wallboard, and there was no deterioration of thermal energy storage capacity. In support of this concept, a computer model was developed to handle thermal transport and storage by a phase change material (PCM) dispersed in a porous media. The computer model was confirmed by comparison with known analytical solutions and also by comparison with temperatures measured in wallboard during an experimentally generated thermal transient. Agreement between the model and known solution was excellent. Agreement between the model and thermal transient was good, only after the model was modified to allow the PCM to melt over a temperature range, rather than at a specific melting point. When the melting characteristics of the PCM (melting point, melting range, and heat of fusion), as determined from a differential scanning calorimeter plot, were used in the model, agreement between the model and transient data was very good. The confirmed computer model may now be used in conjunction with a building heating and cooling code to evaluate design parameters and operational characteristics of latent heat storage wallboard for passive solar applications.

  3. Effects of passive heat stress on human somatosensory processing.

    PubMed

    Nakata, Hiroki; Oshiro, Misaki; Namba, Mari; Shibasaki, Manabu

    2015-12-01

    Herein, we investigated the effects of passive heat stress on human somatosensory processing recorded by somatosensory-evoked potentials (SEPs). Fifteen healthy subjects received a median nerve stimulation at the left wrist under two thermal conditions: Heat Stress and normothermic Time Control. The latencies and amplitudes of P14, N20, P25, N35, P45, and N60 at C4' and P14, N18, P22, and N30 at Fz were evaluated. Under the Heat Stress condition, SEPs were recorded at normothermic baseline (1st), early in heat stress (2nd), when esophageal temperature had increased by ~1.0°C (3rd) and ~2.0°C (4th), and after heat stress (5th). In the Time Control condition, SEPs were measured at the same time intervals as those in the Heat Stress condition. The peak latencies and amplitudes of SEPs did not change early in heat stress. However, the latencies of P14, N20, and N60 at C4' and P14, N18, and P22 at Fz were significantly shorter in the 4th session than in the 1st session. Furthermore, the peak amplitudes of P25 and N60 at C4', and P22 and N30 at Fz decreased with increases in body temperature. On the other hand, under the Time Control condition, no significant differences were observed in the amplitudes or latencies of any component of SEPs. These results suggested that the conduction velocity of the ascending somatosensory input was accelerated by increases in body temperature, and hyperthermia impaired the neural activity of cortical somatosensory processing. PMID:26468258

  4. Nuclear reactor with makeup water assist from residual heat removal system

    DOEpatents

    Corletti, M.M.; Schulz, T.L.

    1993-12-07

    A pressurized water nuclear reactor uses its residual heat removal system to make up water in the reactor coolant circuit from an in-containment refueling water supply during staged depressurization leading up to passive emergency cooling by gravity feed from the refueling water storage tank, and flooding of the containment building. When depressurization commences due to inadvertence or a manageable leak, the residual heat removal system is activated manually and prevents flooding of the containment when such action is not necessary. Operation of the passive cooling system is not impaired. A high pressure makeup water storage tank is coupled to the reactor coolant circuit, holding makeup coolant at the operational pressure of the reactor. The staged depressurization system vents the coolant circuit to the containment, thus reducing the supply of makeup coolant. The level of makeup coolant can be sensed to trigger opening of successive depressurization conduits. The residual heat removal pumps move water from the refueling water storage tank into the coolant circuit as the coolant circuit is depressurized, preventing reaching the final depressurization stage unless the makeup coolant level continues to drop. The residual heat removal system can also be coupled in a loop with the refueling water supply tank, for an auxiliary heat removal path. 2 figures.

  5. Nuclear reactor with makeup water assist from residual heat removal system

    DOEpatents

    Corletti, Michael M.; Schulz, Terry L.

    1993-01-01

    A pressurized water nuclear reactor uses its residual heat removal system to make up water in the reactor coolant circuit from an in-containment refueling water supply during staged depressurization leading up to passive emergency cooling by gravity feed from the refueling water storage tank, and flooding of the containment building. When depressurization commences due to inadvertence or a manageable leak, the residual heat removal system is activated manually and prevents flooding of the containment when such action is not necessary. Operation of the passive cooling system is not impaired. A high pressure makeup water storage tank is coupled to the reactor coolant circuit, holding makeup coolant at the operational pressure of the reactor. The staged depressurization system vents the coolant circuit to the containment, thus reducing the supply of makeup coolant. The level of makeup coolant can be sensed to trigger opening of successive depressurization conduits. The residual heat removal pumps move water from the refueling water storage tank into the coolant circuit as the coolant circuit is depressurized, preventing reaching the final depressurization stage unless the makeup coolant level continues to drop. The residual heat removal system can also be coupled in a loop with the refueling water supply tank, for an auxiliary heat removal path.

  6. Passive removal of manganese from acid mine drainage

    SciTech Connect

    Brant, D.L.; Ziemkiewicz, P.F.

    1997-12-31

    Removal of manganese (Mn) from mine drainage is difficult due to the abnormal chemistry of the element. The removal requires the oxidation of Mn(II) (the form found in mine drainage) to the more oxidized forms (Mn(III) or Mn(IV)). The more oxidized forms exist only as solids and will not return to Mn(II) spontaneously. Chemical treatment of Mn often requires a pH near 10 to initiate the oxidation quickly. A stabilized pH of 10 normally causes more harm to aquatic organisms than the Mn and is not desirable, making additional steps in the treatment necessary. Biological removal of Mn can be achieved at near neutral pH levels. The Shade Mining site in Somerset County, PA has been treating Mn to discharge limits since the early 1990`s (reducing Mn concentrations from 12 - 25 mg/L in the influent to <2 mg/L in the effluent). The treatment system consists of an anoxic limestone drain discharging into a wetland to remove iron, aluminum, and acidity, while increasing pH and alkalinity. The wetland effluent flows into two limestone beds (Mn removal). The limestone beds developed a black slime coating as the Mn removal increased. This system continues to remove Mn in all weather conditions and has not required chemical treatment since the black coating appeared on the limestone. A laboratory study was conducted using limestone collected from the Shade site to use the same naturally occurring Mn oxidizing microbes. The lab study compared W removal rates of microbial oxidation, MnO{sub 2} catalyzed limestone, and fresh uncoated limestone. The microbial removal performed the best (25 mg/L Mn reduced to <2 mg/L in 72 hours).

  7. Solution of heat removal from nuclear reactors by natural convection

    NASA Astrophysics Data System (ADS)

    Zitek, Pavel; Valenta, Vaclav

    2014-03-01

    This paper summarizes the basis for the solution of heat removal by natural convection from both conventional nuclear reactors and reactors with fuel flowing coolant (such as reactors with molten fluoride salts MSR).The possibility of intensification of heat removal through gas lift is focused on. It might be used in an MSR (Molten Salt Reactor) for cleaning the salt mixture of degassed fission products and therefore eliminating problems with iodine pitting. Heat removal by natural convection and its intensification increases significantly the safety of nuclear reactors. Simultaneously the heat removal also solves problems with lifetime of pumps in the primary circuit of high-temperature reactors.

  8. Design and Scaling of the Natural Convection Shutdown Heat Removal Test Facility

    SciTech Connect

    Lisowski, Darius D.; Gerardi, Craig D.; Bremer, Nathan C.; Farmer, Mitchell T.

    2014-01-01

    The Natural convection Shutdown heat removal Test Facility (NSTF) at Argonne National Laboratory (ANL) reflects a 1/2 scale model of one conceptual design for passive safety in advanced reactors. The project was initiated in 2010 primarily to conduct ex-vessel, passive decay heat removal experiments in support of the Advanced Reactor Concepts (ARC), Small Modular Reactor (SMR), and Next Generation Nuclear Plant (NGNP) programs while also generating data for code validation purposes. The facility successfully demonstrated scoping objectives in late 2013, and is expected to begin testing by early 2014. The following paper summarizes some of the key design and scaling considerations used in construction of the experimental facility, along with an overview of the current instrumentation and data acquisition methods. Details of the distributed fiber optic temperature system will be presented, which introduces a level of data density suitable for CFD validation and is a first-of-its-kind for largescale thermal hydraulics facilities.

  9. Emergency heat removal system for a nuclear reactor

    DOEpatents

    Dunckel, Thomas L.

    1976-01-01

    A heat removal system for nuclear reactors serving as a supplement to an Emergency Core Cooling System (ECCS) during a Loss of Coolant Accident (LOCA) comprises a plurality of heat pipes having one end in heat transfer relationship with either the reactor pressure vessel, the core support grid structure or other in-core components and the opposite end located in heat transfer relationship with a heat exchanger having heat transfer fluid therein. The heat exchanger is located external to the pressure vessel whereby excessive core heat is transferred from the above reactor components and dissipated within the heat exchanger fluid.

  10. Age alters the cardiovascular response to direct passive heating

    NASA Technical Reports Server (NTRS)

    Minson, C. T.; Wladkowski, S. L.; Cardell, A. F.; Pawelczyk, J. A.; Kenney, W. L.

    1998-01-01

    During direct passive heating in young men, a dramatic increase in skin blood flow is achieved by a rise in cardiac output (Qc) and redistribution of flow from the splanchnic and renal vascular beds. To examine the effect of age on these responses, seven young (Y; 23 +/- 1 yr) and seven older (O; 70 +/- 3 yr) men were passively heated with water-perfused suits to their individual limit of thermal tolerance. Measurements included heart rate (HR), Qc (by acetylene rebreathing), central venous pressure (via peripherally inserted central catheter), blood pressures (by brachial auscultation), skin blood flow (from increases in forearm blood flow by venous occlusion plethysmography), splanchnic blood flow (by indocyanine green clearance), renal blood flow (by p-aminohippurate clearance), and esophageal and mean skin temperatures. Qc was significantly lower in the older than in the young men (11.1 +/- 0.7 and 7.4 +/- 0.2 l/min in Y and O, respectively, at the limit of thermal tolerance; P < 0. 05), despite similar increases in esophageal and mean skin temperatures and time to reach the limit of thermal tolerance. A lower stroke volume (99 +/- 7 and 68 +/- 4 ml/beat in Y and O, respectively, P < 0.05), most likely due to an attenuated increase in inotropic function during heating, was the primary factor for the lower Qc observed in the older men. Increases in HR were similar in the young and older men; however, when expressed as a percentage of maximal HR, the older men relied on a greater proportion of their chronotropic reserve to obtain the same HR response (62 +/- 3 and 75 +/- 4% maximal HR in Y and O, respectively, P < 0.05). Furthermore, the older men redistributed less blood flow from the combined splanchnic and renal circulations at the limit of thermal tolerance (960 +/- 80 and 720 +/- 100 ml/min in Y and O, respectively, P < 0. 05). As a result of these combined attenuated responses, the older men had a significantly lower increase in total blood flow directed to

  11. Wallboard with latent heat storage for passive solar applications

    SciTech Connect

    Kedl, R.J.

    1991-05-01

    Conventional wallboard impregnated with octadecane paraffin is being developed as a building material with latent heat storage for passive solar and other applications. Impregnation was accomplished simply by soaking the wallboard in molten wax. Concentrations of wax in the combined product as high as 35% by weight can be achieved. Scale-up of the soaking process, from small laboratory samples to full-sized 4- by 8-ft sheets, has been successfully accomplished. The required construction properties of wallboard are maintained after impregnation, that is, it can be painted and spackled. Long-term, high-temperature exposure tests and thermal cycling tests showed no tendency of the paraffin to migrate within the wallboard, and there was no deterioration of thermal energy storage capacity. In support of this concept, a computer model was developed to handle thermal transport and storage by a phase change material (PCM) dispersed in a porous media. The computer model was confirmed by comparison with known analytical solutions and also by comparison with temperatures measured in wallboard during an experimentally generated thermal transient. Agreement between the model and known solution was excellent. Agreement between the model and thermal transient was good, only after the model was modified to allow the PCM to melt over a temperature range, rather than at a specific melting point. When the melting characteristics of the PCM, as determined from a differential scanning calorimeter plot, were used in the model, agreement between the model and transient data was very good. 11 refs., 25 figs., 2 tabs.

  12. Heat exchanger device and method for heat removal or transfer

    SciTech Connect

    Koplow, Jeffrey P

    2015-03-24

    Systems and methods for a forced-convection heat exchanger are provided. In one embodiment, heat is transferred to or from a thermal load in thermal contact with a heat conducting structure, across a narrow air gap, to a rotating heat transfer structure immersed in a surrounding medium such as air.

  13. Heat exchanger device and method for heat removal or transfer

    SciTech Connect

    Koplow, Jeffrey P.

    2015-12-08

    Systems and methods for a forced-convection heat exchanger are provided. In one embodiment, heat is transferred to or from a thermal load in thermal contact with a heat conducting structure, across a narrow air gap, to a rotating heat transfer structure immersed in a surrounding medium such as air.

  14. Heat exchanger device and method for heat removal or transfer

    SciTech Connect

    Koplow, Jeffrey P

    2013-12-10

    Systems and methods for a forced-convection heat exchanger are provided. In one embodiment, heat is transferred to or from a thermal load in thermal contact with a heat conducting structure, across a narrow air gap, to a rotating heat transfer structure immersed in a surrounding medium such as air.

  15. Heat exchanger device and method for heat removal or transfer

    DOEpatents

    Koplow, Jeffrey P.

    2012-07-24

    Systems and methods for a forced-convection heat exchanger are provided. In one embodiment, heat is transferred to or from a thermal load in thermal contact with a heat conducting structure, across a narrow air gap, to a rotating heat transfer structure immersed in a surrounding medium such as air.

  16. Observation of trapped gas during electrical resistance heating of trichloroethylene under passive venting conditions.

    PubMed

    Martin, E J; Kueper, B H

    2011-11-01

    A two-dimensional experiment employing a heterogeneous sand pack incorporating two pools of trichloroethylene (TCE) was performed to assess the efficacy of electrical resistance heating (ERH) under passive venting conditions. Temperature monitoring displayed the existence of a TCE-water co-boiling plateau at 73.4°C, followed by continued heating to 100°C. A 5cm thick gas accumulation formed beneath a fine-grained capillary barrier during and after co-boiling. The capillary barrier did not desaturate during the course of the experiment; the only pathway for gas escape being through perforated wells traversing the barrier. The thickness of the accumulation was dictated by the entry pressure of the perforated well. The theoretical maximum TCE soil concentration within the region of gas accumulation, following gas collapse, was estimated to be 888mg/kg. Post-heating soil sampling revealed TCE concentrations in this region ranging from 27mg/kg to 96.7mg/kg, indicating removal of aqueous and gas phase TCE following co-boiling as a result of subsequent boiling of water. The equilibrium concentrations of TCE in water corresponding to the range of post-treatment concentrations in soil (6.11mg/kg to 136mg/kg) are calculated to range from 19.8mg/l to 440mg/l. The results of this experiment illustrate the importance of providing gas phase venting during the application of ERH in heterogeneous porous media.

  17. Decision Document for Heat Removal from High Level Waste Tanks

    SciTech Connect

    WILLIS, W.L.

    2000-07-31

    This document establishes the combination of design and operational configurations that will be used to provide heat removal from high-level waste tanks during Phase 1 waste feed delivery to prevent the waste temperature from exceeding tank safety requirement limits. The chosen method--to use the primary and annulus ventilation systems to remove heat from the high-level waste tanks--is documented herein.

  18. Passive cryogenic cooling of electrooptics with a heat pipe/radiator.

    PubMed

    Nelson, B E; Goldstein, G A

    1974-09-01

    The current status of the heat pipe is discussed with particular emphasis on applications to cryogenic thermal control. The competitive nature of the passive heat pipe/radiator system is demonstrated through a comparative study with other candidate systems for a 1-yr mission. The mission involves cooling a spaceborne experiment to 100 K while it dissipates 10 W.

  19. Experimental and theoretical study of horizontal tube bundle for passive condensation heat transfer

    NASA Astrophysics Data System (ADS)

    Song, Yong Jae

    The research in this thesis supports the design of a horizontal tube bundle condenser for passive heat removal system in nuclear reactors. From nuclear power plant containment, condensation of steam from a steam/noncondensable gas occurs on the primary side and boiling occurs on the secondary side; thus, heat exchanger modeling is a challenge. For the purpose of this experimental study, a six-tube bundle is used, where the outer diameter, inner diameter, and length of each stainless steel tube measures 38.10mm (1.5 inches), 31.75mm (1.25 inches) and 3.96m (156 inches), respectively. The pitch to diameter ratio was determined based on information gathered from literature surveys, and the dimensions were determined from calculations and experimental data. The objective of the calculations, correlations, and experimental data was to obtain complete condensation within the tube bundle. Experimental conditions for the tests in this thesis work were determined from Design Basis Accident (DBA). The applications are for an actual Passive Containment Cooling Systems (PCCS) condenser under postulated accident conditions in future light water reactors. In this research, steady state and transient experiments were performed to investigate the effect of noncondensable gas on steam condensation inside and boiling outside a tube bundle heat exchanger. The condenser tube inlet steam mass flow rate varied from 18.0 to 48.0 g/s, the inlet pressure varied from 100 kPa to 400 kPa, and the inlet noncondensable gas mass fraction varied from 1% to 10%. The effect of the noncondensable gas was examined by comparing the tube centerline temperatures for various inlet and system conditions. As a result, it was determined that the noncondensable gas accumulated near the condensate film causing a decrease of mass and energy transfer. In addition, the effect of the inlet steam flow rate gas was investigated by comparing the tube centerline temperatures, the conclusion being that, as the inlet

  20. Report on tests of a passive phase change solar diode for space heating

    SciTech Connect

    Maloney, T.J.; Wattles, G.S.

    1982-01-01

    Passive solar space conditioning systems suffer from the need for, and high cost of movable insulation devices to limit nighttime losses. Additionally, phase change materials (PCM) which melt only partially have been found to be less than cost-effective when compared to the low cost and predictable performance of water mass. Current PCM products used in passive applications suffer from low melt percentages due to insufficient exposure to insolation. Flow visualization tests under heating and cooling cycles have shown a unique diode device to show promise for space heating, cooling and water heating applications.

  1. Effects of one-sided heat input and removal on axially grooved heat pipe performance

    NASA Technical Reports Server (NTRS)

    Kamotani, Y.

    1977-01-01

    The performance of an axially grooved heat pipe with one-sided heat input and removal was investigated analytically. Under zero-g condition the maximum heat transport of the pipe may decrease as much as 30% depending on the liquid slug behavior in the condenser section. In one-g environment the performance depends mainly on the fluid charge. The maximum heat transport, if over-charged, is almost equal to the value for uniform heating and cooling due to puddling effect. However, for some heater-cooler combinations the temperature drop across the heat pipe becomes very large. Computed results for tilted heat pipes compare favorably with available experimental data.

  2. Heat exchanger and water tank arrangement for passive cooling system

    SciTech Connect

    Gillett, James E.; Johnson, F. Thomas; Orr, Richard S.; Schulz, Terry L.

    1993-01-01

    A water storage tank in the coolant water loop of a nuclear reactor contains a tubular heat exchanger. The heat exchanger has tubesheets mounted to the tank connections so that the tubesheets and tubes may be readily inspected and repaired. Preferably, the tubes extend from the tubesheets on a square pitch and then on a rectangular pitch therebetween. Also, the heat exchanger is supported by a frame so that the tank wall is not required to support all of its weight.

  3. Passive solar space heating and cooling. (Latest citations from the NTIS Bibliographic database). NewSearch

    SciTech Connect

    Not Available

    1994-10-01

    The bibliography contains citations concerning the passive use of solar energy for space heating and cooling in buildings, houses, and homes. Citations discuss the design, performance, models, and economic analysis of heating and cooling systems. Topics include solar architecture, energy consumption analysis, energy conservation, and heat recovery. Also included are thermal comfort, quality of life, and housing for the elderly. (Contains a minimum of 209 citations and includes a subject term index and title list.)

  4. No effects of acclimation to heat on immune and hormonal responses to passive heating in healthy volunteers

    NASA Astrophysics Data System (ADS)

    Kanikowska, Dominika; Sato, Maki; Sugenoya, Junichi; Iwase, Satoshi; Shimizu, Yuuki; Nishimura, Naoki; Inukai, Yoko

    2012-01-01

    Heat acclimation results in whole body-adaptations that increase heat tolerance, and might also result in changed immune responses. We hypothesized that, after heat acclimation, tumor necrosis factor alpha, interleukin 6 and the lymphocyte count would be altered. Heat acclimation was induced in 6 healthy men by 100 min of heat exposure for 9 days. Heat exposure consisted of (1) 10 min of immersion up to chest-level in water at 42°C and (2) 90 min of passive heating by a warm blanket to maintain tympanic temperature at 37.5°C. The climatic chamber was maintained at 40°C and a relative humidity of 50%. Blood samples were analyzed before and after heat acclimation for natural killer (NK) cell activity, counts of lymphocytes B and T, before and after heat acclimation for peripheral blood morphology, interleukin 6, tumor necrosis factor alpha, and cortisol. A Japanese version of the profile of mood states questionnaire was also administered before and after acclimation. The concentrations of white blood cells, lymphocytes B and T, cortisol, interleukin 6, tumor necrosis factor alpha and NK cell activity showed no significant differences between pre- and post-acclimation, but there was a significantly lower platelet count after acclimation and, with the profile of mood states questionnaire, there was a significant rise in anger after acclimation. It is concluded that heat acclimation by passive heating does not induce alterations in immune or endocrine responses.

  5. Observation of trapped gas during electrical resistance heating of trichloroethylene under passive venting conditions.

    PubMed

    Martin, E J; Kueper, B H

    2011-11-01

    A two-dimensional experiment employing a heterogeneous sand pack incorporating two pools of trichloroethylene (TCE) was performed to assess the efficacy of electrical resistance heating (ERH) under passive venting conditions. Temperature monitoring displayed the existence of a TCE-water co-boiling plateau at 73.4°C, followed by continued heating to 100°C. A 5cm thick gas accumulation formed beneath a fine-grained capillary barrier during and after co-boiling. The capillary barrier did not desaturate during the course of the experiment; the only pathway for gas escape being through perforated wells traversing the barrier. The thickness of the accumulation was dictated by the entry pressure of the perforated well. The theoretical maximum TCE soil concentration within the region of gas accumulation, following gas collapse, was estimated to be 888mg/kg. Post-heating soil sampling revealed TCE concentrations in this region ranging from 27mg/kg to 96.7mg/kg, indicating removal of aqueous and gas phase TCE following co-boiling as a result of subsequent boiling of water. The equilibrium concentrations of TCE in water corresponding to the range of post-treatment concentrations in soil (6.11mg/kg to 136mg/kg) are calculated to range from 19.8mg/l to 440mg/l. The results of this experiment illustrate the importance of providing gas phase venting during the application of ERH in heterogeneous porous media. PMID:22115093

  6. Heat transfer measurements in ONERA supersonic and hypersonic wind tunnels using passive and active infrared thermography

    NASA Astrophysics Data System (ADS)

    Balageas, D.; Boscher, D.; Deom, A.; Gardette, G.

    Over the past few years, a major intellectual and technical investment has been made at ONERA to use data acquisition systems and data reduction procedures using an infrared camera as a detector under routine wind tunnel conditions. This allows a really quantitative mapping of heat transfer rate distributions on models in supersonic and hypersonic flows. Sufficient experience has now been acquired to allow us to give an overview of: (1) the systems and data reduction procedures developed for both passive and active methods; (2) typical results obtained on various configurations such as supersonic axisymmetrical flow around an ogival body (passive and active thermography), heat flux modulation in the reattachment zone of a flap in hypersonic regime, transitional heating on very slightly blunted spheroconical bodies in hypersonic flows, and materials testing in high-enthalpy hypersonic flow (passive thermography).

  7. Passive Removal of Silicone Oil with Temporal Head Position through Two 23-Gauge Cannulas.

    PubMed

    Lin, Zhong; Ke, Zhi Sheng; Zheng, Qian; Zhao, Zhen Quan; Song, Zong Ming

    2016-01-01

    Purpose. To report a new approach for removal of silicone oil. Methods. All surgeries were performed using 23-gauge vitrectomy system with two transconjunctival sutureless cannulas. At the beginning, most of the silicone oil was removed by traditional microinvasive vitrectomy system through inferior-temporal cannula. Then, the blood transfusion tube is removed from the inferior-temporal cannula, and the fluid-air exchange is performed. A passive fluid-air exchange was performed to aspirate the residual silicone oil after gradually turning the patient's head temporally by approximately 90° gradually. Results. After the surgery, all patients had a clear anterior chamber and vitreous cavity on slit lamp and B scan examination, respectively. The mean time taken for silicone oil removal and total surgery was 8.0 ± 1.4 minutes and 12.4 ± 2.5 minutes, respectively. The mean intraocular pressure 1 day, 3 days, 1 week, 1 month, and 3 months after surgery was 9.0 ± 5.8 mmHg, 11.3 ± 7.6 mmHg, 16.1 ± 6.9 mmHg, 17.7 ± 4.8 mmHg, and 17.1 ± 3.5 mmHg, respectively. Conclusion. This new approach may provide a safe and fast method to remove the silicone oil.

  8. Passive Removal of Silicone Oil with Temporal Head Position through Two 23-Gauge Cannulas

    PubMed Central

    Lin, Zhong; Ke, Zhi Sheng; Zheng, Qian; Zhao, Zhen Quan; Song, Zong Ming

    2016-01-01

    Purpose. To report a new approach for removal of silicone oil. Methods. All surgeries were performed using 23-gauge vitrectomy system with two transconjunctival sutureless cannulas. At the beginning, most of the silicone oil was removed by traditional microinvasive vitrectomy system through inferior-temporal cannula. Then, the blood transfusion tube is removed from the inferior-temporal cannula, and the fluid-air exchange is performed. A passive fluid-air exchange was performed to aspirate the residual silicone oil after gradually turning the patient's head temporally by approximately 90° gradually. Results. After the surgery, all patients had a clear anterior chamber and vitreous cavity on slit lamp and B scan examination, respectively. The mean time taken for silicone oil removal and total surgery was 8.0 ± 1.4 minutes and 12.4 ± 2.5 minutes, respectively. The mean intraocular pressure 1 day, 3 days, 1 week, 1 month, and 3 months after surgery was 9.0 ± 5.8 mmHg, 11.3 ± 7.6 mmHg, 16.1 ± 6.9 mmHg, 17.7 ± 4.8 mmHg, and 17.1 ± 3.5 mmHg, respectively. Conclusion. This new approach may provide a safe and fast method to remove the silicone oil. PMID:27418976

  9. Heat exchanger and water tank arrangement for passive cooling system

    DOEpatents

    Gillett, J.E.; Johnson, F.T.; Orr, R.S.; Schulz, T.L.

    1993-11-30

    A water storage tank in the coolant water loop of a nuclear reactor contains a tubular heat exchanger. The heat exchanger has tube sheets mounted to the tank connections so that the tube sheets and tubes may be readily inspected and repaired. Preferably, the tubes extend from the tube sheets on a square pitch and then on a rectangular pitch there between. Also, the heat exchanger is supported by a frame so that the tank wall is not required to support all of its weight. 6 figures.

  10. Device for removing heat of decomposition in a steam power plant heated by nuclear energy

    SciTech Connect

    Emsperger, W.; Werker, E.

    1980-12-02

    Device for removing heat of decomposition in a steam power plant heated by nuclear energy and having a steam generator with a water-steam separating tank connected downstream of the steam generator in travel direction of the steam generated thereby includes a start-up circulatory loop for the steam power plant connected to the steam generator and including the water-steam separating tank therein, the start-up circulatory loop being formed of a feed water line and an outlet line from the water-steam separating tank and further including an externally cooled heat exchanger connected therein for removing after-heat.

  11. Alternative cooling resource for removing the residual heat of reactor

    SciTech Connect

    Park, H. C.; Lee, J. H.; Lee, D. S.; Jung, C. Y.; Choi, K. Y.

    2012-07-01

    The Recirculated Cooling Water (RCW) system of a Candu reactor is a closed cooling system which delivers demineralized water to coolers and components in the Service Building, the Reactor Building, and the Turbine Building and the recirculated cooling water is designed to be cooled by the Raw Service Water (RSW). During the period of scheduled outage, the RCW system provides cooling water to the heat exchangers of the Shutdown Cooling System (SDCS) in order to remove the residual heat of the reactor, so the RCW heat exchangers have to operate at all times. This makes it very hard to replace the inlet and outlet valves of the RCW heat exchangers because the replacement work requires the isolation of the RCW. A task force was formed to prepare a plan to substitute the recirculated water with the chilled water system in order to cool the SDCS heat exchangers. A verification test conducted in 2007 proved that alternative cooling was possible for the removal of the residual heat of the reactor and in 2008 the replacement of inlet and outlet valves of the RCW heat exchangers for both Wolsong unit 3 and 4 were successfully completed. (authors)

  12. Decay heat removal systems: design criteria and options. [PWR; BWR

    SciTech Connect

    Berry, D.L.

    1980-01-01

    Design criteria and alternate decay heat removal system concepts which have evolved in several different countries throughout the world were compared. The conclusion was reached that the best way to improve the reliability of pressurized water reactor (PWR) decay heat removal is first to focus on improving the reliability of the auxiliary feedwater and high pressure injection systems to cope with certain loss of feedwater transients and small loss of coolant accidents and then to assess how well these systems can handle special emergencies (e.g., sabotage, earthquake, airplane crash). For boiling water reactors (BWRs), it was concluded that emphasis should be placed first on improving the reliability of the residual heat removal and high pressure service water systems to cope with a loss of suppression pool cooling following a loss of feedwater transient and then to assess how well these systems can handle special emergencies. It was found that, for both PWRs and BWRs, a design objective for alternate decay heat removal systems should be at least an order of magnitude reduction in core meltdown probability.

  13. Long-term performance of passive materials for removal of ozone from indoor air.

    PubMed

    Cros, C J; Morrison, G C; Siegel, J A; Corsi, R L

    2012-02-01

    The health effects associated with exposure to ozone range from respiratory irritation to increased mortality. In this paper, we explore the use of three green building materials and an activated carbon (AC) mat that remove ozone from indoor air. We studied the effects of long-term exposure of these materials to real environments on ozone removal capability and pre- and post-ozonation emissions. A field study was completed over a 6-month period, and laboratory testing was intermittently conducted on material samples retrieved from the field. The results show sustained ozone removal for all materials except recycled carpet, with greatest ozone deposition velocity for AC mat (2.5-3.8 m/h) and perlite-based ceiling tile (2.2-3.2 m/h). Carbonyl emission rates were low for AC across all field sites. Painted gypsum wallboard and perlite-based ceiling tile had similar overall emission rates over the 6-month period, while carpet had large initial emission rates of undesirable by-products that decayed rapidly but remained high compared with other materials. This study confirms that AC mats and perlite-based ceiling tile are viable surfaces for inclusion in buildings to remove ozone without generating undesirable by-products. PRACTICAL IMPLICATIONS The use of passive removal materials for ozone control could decrease the need for, or even render unnecessary, active but energy consuming control solutions. In buildings where ozone should be controlled (high outdoor ozone concentrations, sensitive populations), materials specifically designed or selected for removing ozone could be implemented, as long as ozone removal is not associated with large emissions of harmful by-products. We find that activated carbon mats and perlite-based ceiling tiles can provide substantial, long-lasting, ozone control.

  14. Decay Heat Removal in GEN IV Gas-Cooled Fast Reactors

    DOE PAGESBeta

    Cheng, Lap-Yan; Wei, Thomas Y. C.

    2009-01-01

    The safety goal of the current designs of advanced high-temperature thermal gas-cooled reactors (HTRs) is that no core meltdown would occur in a depressurization event with a combination of concurrent safety system failures. This study focused on the analysis of passive decay heat removal (DHR) in a GEN IV direct-cycle gas-cooled fast reactor (GFR) which is based on the technology developments of the HTRs. Given the different criteria and design characteristics of the GFR, an approach different from that taken for the HTRs for passive DHR would have to be explored. Different design options based on maintaining core flow weremore » evaluated by performing transient analysis of a depressurization accident using the system code RELAP5-3D. The study also reviewed the conceptual design of autonomous systems for shutdown decay heat removal and recommends that future work in this area should be focused on the potential for Brayton cycle DHRs.« less

  15. Characterization of robotic system passive path repeatability during specimen removal and reinstallation for in vitro knee joint testing.

    PubMed

    Goldsmith, Mary T; Smith, Sean D; Jansson, Kyle S; LaPrade, Robert F; Wijdicks, Coen A

    2014-10-01

    Robotic testing systems are commonly utilized for the study of orthopaedic biomechanics. Quantification of system error is essential for reliable use of robotic systems. Therefore, the purpose of this study was to quantify a 6-DOF robotic system's repeatability during knee biomechanical testing and characterize the error induced in passive path repeatability by removing and reinstalling the knee. We hypothesized removing and reinstalling the knee would substantially alter passive path repeatability. Testing was performed on four fresh-frozen cadaver knees. To determine repeatability and reproducibility, the passive path was collected three times per knee following the initial setup (intra-setup), and a single time following two subsequent re-setups (inter-setup). Repeatability was calculated as root mean square error. The intra-setup passive path had a position repeatability of 0.23 mm. In contrast, inter-setup passive paths had a position repeatability of 0.89 mm. When a previously collected passive path was replayed following re-setup of the knee, resultant total force repeatability across the passive path increased to 28.2N (6.4N medial-lateral, 25.4N proximal-distal, and 10.5 N anterior-posterior). This study demonstrated that removal and re-setup of a knee can have substantial, clinically significant changes on our system's repeatability and ultimately, accuracy of the reported results.

  16. Cognitive and perceptual responses during passive heat stress in younger and older adults

    PubMed Central

    Schlader, Zachary J.; Gagnon, Daniel; Adams, Amy; Rivas, Eric; Cullum, C. Munro

    2015-01-01

    We tested the hypothesis that attention, memory, and executive function are impaired to a greater extent in passively heat-stressed older adults than in passively heat-stressed younger adults. In a randomized, crossover design, 15 older (age: 69 ± 5 yr) and 14 younger (age: 30 ± 4 yr) healthy subjects underwent passive heat stress and time control trials. Cognitive tests (outcomes: accuracy and reaction time) from the CANTAB battery evaluated attention [rapid visual processing (RVP), choice reaction time (CRT)], memory [spatial span (SSP), pattern recognition memory (PRM)], and executive function [one touch stockings of Cambridge (OTS)]. Testing was undertaken on two occasions during each trial, at baseline and after internal temperature had increased by 1.0 ± 0.2°C or after a time control period. For tests that measured attention, reaction time during RVP and CRT was slower (P ≤ 0.01) in the older group. During heat stress, RVP reaction time improved (P < 0.01) in both groups. Heat stress had no effect (P ≥ 0.09) on RVP or CRT accuracy in either group. For tests that measured memory, accuracy on SSP and PRM was lower (P < 0.01) in the older group, but there was no effect of heat stress (P ≥ 0.14). For tests that measured executive function, overall, accuracy on OTS was lower, and reaction time was slower in the older group (P ≤ 0.05). Reaction time generally improved during heat stress, but there was no effect of heat stress on accuracy in either group. These data indicate that moderate increases in body temperature during passive heat stress do not differentially compromise cognitive function in younger and older adults. PMID:25786484

  17. Cognitive and perceptual responses during passive heat stress in younger and older adults.

    PubMed

    Schlader, Zachary J; Gagnon, Daniel; Adams, Amy; Rivas, Eric; Cullum, C Munro; Crandall, Craig G

    2015-05-15

    We tested the hypothesis that attention, memory, and executive function are impaired to a greater extent in passively heat-stressed older adults than in passively heat-stressed younger adults. In a randomized, crossover design, 15 older (age: 69 ± 5 yr) and 14 younger (age: 30 ± 4 yr) healthy subjects underwent passive heat stress and time control trials. Cognitive tests (outcomes: accuracy and reaction time) from the CANTAB battery evaluated attention [rapid visual processing (RVP), choice reaction time (CRT)], memory [spatial span (SSP), pattern recognition memory (PRM)], and executive function [one touch stockings of Cambridge (OTS)]. Testing was undertaken on two occasions during each trial, at baseline and after internal temperature had increased by 1.0 ± 0.2°C or after a time control period. For tests that measured attention, reaction time during RVP and CRT was slower (P ≤ 0.01) in the older group. During heat stress, RVP reaction time improved (P < 0.01) in both groups. Heat stress had no effect (P ≥ 0.09) on RVP or CRT accuracy in either group. For tests that measured memory, accuracy on SSP and PRM was lower (P < 0.01) in the older group, but there was no effect of heat stress (P ≥ 0.14). For tests that measured executive function, overall, accuracy on OTS was lower, and reaction time was slower in the older group (P ≤ 0.05). Reaction time generally improved during heat stress, but there was no effect of heat stress on accuracy in either group. These data indicate that moderate increases in body temperature during passive heat stress do not differentially compromise cognitive function in younger and older adults.

  18. Ethnic differences in thermoregulatory responses during resting, passive and active heating: application of Werner's adaptation model.

    PubMed

    Lee, Joo-Young; Wakabayashi, Hitoshi; Wijayanto, Titis; Hashiguchi, Nobuko; Saat, Mohamed; Tochihara, Yutaka

    2011-12-01

    For the coherent understanding of heat acclimatization in tropical natives, we compared ethnic differences between tropical and temperate natives during resting, passive and active heating conditions. Experimental protocols included: (1) a resting condition (an air temperature of 28°C with 50% RH), (2) a passive heating condition (28°C with 50% RH; leg immersion in a hot tub at a water temperature of 42°C), and (3) an active heating condition (32°C with 70% RH; a bicycle exercise). Morphologically and physically matched tropical natives (ten Malaysian males, MY) and temperate natives (ten Japanese males, JP) participated in all three trials. The results saw that: tropical natives had a higher resting rectal temperature and lower hand and foot temperatures at rest, smaller rise of rectal temperature and greater temperature rise in bodily extremities, and a lower sensation of thirst during passive and active heating than the matched temperate natives. It is suggested that tropical natives' homeostasis during heating is effectively controlled with the improved stability in internal body temperature and the increased capability of vascular circulation in extremities, with a lower thirst sensation. The enhanced stability of internal body temperature and the extended thermoregulatory capability of vascular circulation in the extremities of tropical natives can be interpreted as an interactive change to accomplish a thermal dynamic equilibrium in hot environments. These heat adaptive traits were explained by Wilder's law of initial value and Werner's process and controller adaptation model.

  19. Heat Deposition and Heat Removal in the UCLA Continuous Current Tokamak

    NASA Astrophysics Data System (ADS)

    Brown, Michael Lee

    1990-01-01

    Energy transfer processes in a steady-state tokamak are examined both theoretically and experimentally in order to determine the patterns of plasma heat deposition to material surfaces and the methods of heat removal. Heat transfer experiments involving actively cooled limiters and heat flux probes were performed in the UCLA Continuous Current Tokamak (CCT). The simple exponential model of plasma power deposition was extended to describe the global heat deposition to the first wall of a steady-state tokamak. The heat flux distribution in CCT was determined from measurements of heat flow to 32 large-area water-cooled Faraday shield panels. Significant toroidal and poloidal asymmetries were observed, with the maximum heat fluxes tending to fall on the lower outside panels. Heat deposition to the water-cooled guard limiters of an ion Bernstein wave antenna in CCT was measured during steady-state operation. Very strong asymmetries were observed. The heat distribution varied greatly with magnetic field. Copper heat flux sensors incorporating internal thermocouples were developed to measure plasma power deposition to exterior probe surfaces and heat removal from water -cooled interior surfaces. The resulting inverse heat conduction problem was solved using the function specification method. Cooling by an impinging liquid jet was investigated. One end of a cylindrical copper heat flux sensor was heated by a DC electrical arc and the other end was cooled by a low velocity water jet at 1 atm. Critical heat flux (CHF) values for the 55-80 ^circC sub-cooled free jets were typically 2.5 times published values for saturated free jets. For constrained jets, CHF values were about 20% lower. Heat deposition and heat removal in thick (3/4 inch diameter) cylindrical metal probes (SS304 or copper) inserted into a steady-state tokamak plasma were measured for a broad range of heat loads. The probes were cooled internally by a constrained jet of either air or water. Steady -state heat

  20. Passive cigarette smoke, coal heating, and respiratory symptoms of nonsmoking women in China

    SciTech Connect

    Pope, C.A. III Brigham Young Univ., Provo, UT ); Xu, X. )

    1993-09-01

    In this study the authors evaluated data from a sample of 973 never-smoking women, ages 20-40, who worked in three similar textile mills in Anhui Province, China. They compared prevalence rates of respiratory symptoms across homes with and without coal heating and homes with different numbers of smokers. Multiple logistic regression models that controlled for age, job title, and mill of employment were also estimated. Respiratory symptoms were associated with combined exposure to passive cigarette smoke and coal heating. Effects of passive cigarette smoke and coal heating on respiratory symptoms appeared to be nearly additive, suggesting a dose-response relationship between respiratory symptoms and home indoor air pollution from these two sources. The prevalence of chest illness, cough, phlegm, and shortness of breath (but not wheeze) was significantly elevated for women living in homes with both smokers and coal heating.

  1. Study of thermosiphon and radiant panel passive heating systems for metal buildings

    SciTech Connect

    Biehl, F.A.; Schnurr, N.M.; Wray, W.O.

    1983-01-01

    A study of passive-heating systems appropriate for use on metal buildings is being conducted at Los Alamos National Laboratory for the Naval Civil Engineering Laboratory, Port Hueneme, California. The systems selected for study were chosen on the basis of their appropriateness for retrofit applications, although they are also suitable for new construction: simple radiant panels that communicate directly with the building interior and a backflow thermosiphon that provides heat indirectly.

  2. Function of human eccrine sweat glands during dynamic exercise and passive heat stress

    NASA Technical Reports Server (NTRS)

    Kondo, N.; Shibasaki, M.; Aoki, K.; Koga, S.; Inoue, Y.; Crandall, C. G.

    2001-01-01

    The purpose of this study was to identify the pattern of change in the density of activated sweat glands (ASG) and sweat output per gland (SGO) during dynamic constant-workload exercise and passive heat stress. Eight male subjects (22.8 +/- 0.9 yr) exercised at a constant workload (117.5 +/- 4.8 W) and were also passively heated by lower-leg immersion into hot water of 42 degrees C under an ambient temperature of 25 degrees C and relative humidity of 50%. Esophageal temperature, mean skin temperature, sweating rate (SR), and heart rate were measured continuously during both trials. The number of ASG was determined every 4 min after the onset of sweating, whereas SGO was calculated by dividing SR by ASG. During both exercise and passive heating, SR increased abruptly during the first 8 min after onset of sweating, followed by a slower increase. Similarly for both protocols, the number of ASG increased rapidly during the first 8 min after the onset of sweating and then ceased to increase further (P > 0.05). Conversely, SGO increased linearly throughout both perturbations. Our results suggest that changes in forearm sweating rate rely on both ASG and SGO during the initial period of exercise and passive heating, whereas further increases in SR are dependent on increases in SGO.

  3. Entirely passive heat-pipe apparatus capable of operating against gravity

    DOEpatents

    Koenig, D.R.

    1981-02-11

    The disclosure is directed to an entirely passive heat pipe apparatus capable of operating against gravity for vertical distances in the order of 3 to 7 and more. A return conduit into which an inert gas is introduced is used to lower the specific density of the working fluid so that it may be returned a greater vertical distance from condenser to evaporator.

  4. (Use of rainwater and greywater and hybrid passive/wood fire water heating). Final report

    SciTech Connect

    Pritchard, D.C.

    1985-01-01

    The work reported involves three phases. The first addresses water heating using a woodstove and a passive solar hot water system. The second deals with recycling greywater. The purpose of the third phase is to use rainwater to fulfill all hot water needs. (LEW)

  5. Effect of plants on sunspace passive solar heating

    SciTech Connect

    Best, E.D.; McFarland, R.D.

    1985-01-01

    The effect of plants on sunspace thermal performance is investigated, based on experiments done in Los Alamos using two test rooms with attached sunspaces, which were essentially identical except for the presence of plants in one. Performance is related to plant transpiration, evaporation from the soil, condensation on the glazing and the absorbtance of solar energy by the lightweight leaves. Performance effects have been quantified by measurements of auxiliary heat consumption in the test rooms and analyzed by means of energy balance calculations. A method for estimating the transpiration rate is presented.

  6. Modeling of Material Removal by Solid State Heat Capacity Lasers

    SciTech Connect

    Boley, C D; Rubenchik, A M

    2002-04-17

    Pulsed lasers offer the capability of rapid material removal. Here we present simulations of steel coupon tests by two solid state heat capacity lasers built at LLNL. Operating at 1.05 pm, these deliver pulse energies of about 80 J at 10 Hz, and about 500 J at 20 Hz. Each is flashlamp-pumped. The first laser was tested at LLNL, while the second laser has been delivered to HELSTF, White Sands Missile Range. Liquid ejection appears to be an important removal mechanism. We have modeled these experiments via a time-dependent code called THALES, which describes heat transport, melting, vaporization, and the hydrodynamics of liquid, vapor, and air. It was previously used, in a less advanced form, to model drilling by copper vapor lasers [1] . It was also used to model vaporization in beam dumps for a high-power laser [2]. The basic model is in 1D, while the liquid hydrodynamics is handled in 2D.

  7. Control system analysis for off-peak auxiliary heating of passive solar systems

    SciTech Connect

    Murray, H.S.; Melsa, J.L.; Balcomb, J.D.

    1980-01-01

    A computer simulation method is presented for the design of an electrical auxiliary energy system for passive solar heated structures. The system consists of electrical mats buried in the ground underneath the structure. Energy is stored in the ground during utility off-peak hours and released passively to the heated enclosure. An optimal control strategy is used to determine the system design parameters of depth of mat placement and minimum instaled electrical heating capacity. The optimal control applies combinations of fixed duration energy pulses to the heater, which minimize the room temperature error-squared for each day, assuming advance knowledge of the day's weather. Various realizable control schemes are investigated in an attempt to find a system that approaches the performance of the optimal control system.

  8. Natural/passive solar heating and cooling for poultry sheds

    SciTech Connect

    Abd El-Salam, E.M.

    1980-12-01

    Arid climates, as in Egypt and the Middle-East regions, are characterized by large durinal and seasonal temperature variation coupled with clear skies and ample sunshine duration. Partial stabilization of indoor thermal environment in habitation is of great comfort for human and have large effects on animals or birds productivities. In case of poultry or animal sheds, can have some economical turn over in terms of increased egg or animal productivity and reduction of mortality rates if their indoor thermal environment is favorably controlled. Poultry birds are sensitive to changes of ambient temperatures, humidity and other environmental variables. This investigation describes an unconventional method of maintaining moderate thermal environment within poultry sheds by using the roof for storage of heat and coolness in appropriate seasons. During winter, underground water is circulated through specially designed pipe matrix imbeded in the roof slab and through radiant wall panels.

  9. Multiple pollutant removal using the condensing heat exchanger

    SciTech Connect

    Jankura, B. J.; Kudlac, G. A.; Bailey, R. T.

    1998-06-01

    The Integrated Flue Gas Treatment (IFGT) system is a new concept whereby a Teflon ® covered condensing heat exchanger is adapted to remove certain flue gas constituents, both particulate and gaseous, while recovering low level heat. The pollutant removal performance and durability of this device is the subject of a USDOE sponsored program to develop this technology. The program was conducted under contract to the United States Department of Energy's Fossil Energy Technology Center (DOE-FETC) and was supported by the Ohio Coal Development Office (OCDO) within the Ohio Department of Development, the Electric Power Research Institute's Environmental Control Technology Center (EPRI-ECTC) and Babcock and Wilcox - a McDermott Company (B&W). This report covers the results of the first phase of this program. This Phase I project has been a two year effort. Phase I includes two experimental tasks. One task dealt principally with the pollutant removal capabilities of the IFGT at a scale of about 1.2MWt. The other task studied the durability of the Teflon ® covering to withstand the rigors of abrasive wear by fly ash emitted as a result of coal combustion. The pollutant removal characteristics of the IFGT system were measured over a wide range of operating conditions. The coals tested included high, medium and low-sulfur coals. The flue gas pollutants studied included ammonia, hydrogen chloride, hydrogen fluoride, particulate, sulfur dioxide, gas phase and particle phase mercury and gas phase and particle phase trace elements. The particulate removal efficiency and size distribution was investigated. These test results demonstrated that the IFGT system is an effective device for both acid gas absorption and fine particulate collection. Although soda ash was shown to be the most effective reagent for acid gas absorption, comparative cost analyses suggested that magnesium enhanced lime was the most promising avenue for future study. The durability of the Teflon

  10. Shellfish mariculture facility which employs passive solar heating and heat pump systems. Performance and cost analysis study. Final report

    SciTech Connect

    Zoto, G.A.; Krabach, M.H.

    1984-06-01

    This report incorporates operations data such as clam growth rates, clam biomass buildup, water volume, and algal food requirements compiled while developing a year-round production schedule for production of hard clam seed. The facility includes a passive solar hatchery and heat pump. Three major areas which affect development of energy-efficient mariculture are addressed: biological operation parameters, energy requirements, and system economics. (LEW)

  11. Damp and dry heat degradation of thermal oxide passivation of p+ silicon

    NASA Astrophysics Data System (ADS)

    Thomson, Andrew; Gardner, Matthew; McIntosh, Keith; Shalav, Avi; Bullock, James

    2014-03-01

    Thermal SiO2 passivates both moderately and heavily doped silicon surfaces irrespective of the dopant type, which is advantageous in high-efficiency solar cell designs. Commercial photovoltaic cells are submitted to accelerated ageing tests, such as damp-heat exposure, to ensure they maintain their performance for at least 20 yr. We find damp-heat exposure causes a severe and rapid degradation of thermal SiO2 passivation on p+ silicon surfaces. The reaction is so severe that the diffused-region recombination in the degraded state is limited by the diffusion of minority carriers to the Si-SiO2 interface not the density of interface defects Dit. Certainly, this effect renders the thermal-oxide passivation useless if employed on a solar cell. To study the cause of the degradation, we also test the effects of storage in dry heat and room ambient conditions. Examination of the rate of degradation in the tested storage conditions in comparison with modelled diffusion of moisture in SiO2, we find a significant correlation between the time dependent J0e and moisture supplied to the interface, leading us to the conclusion that moisture ingression and subsequent reaction at the SiO2-Si interface are the cause of both damp-heat and room- ambient degradation.

  12. Design and testing of a passive, feedback-controlled, variable conductance heat pipe

    NASA Technical Reports Server (NTRS)

    Schlitt, K. R.

    1973-01-01

    A passive feedback system, which stabilizes the heat source temperature (T sub s) of a gas loaded heat pipe, was designed and tested. The control of T sub s is accomplished by an auxiliary liquid that senses the heat source and actuates a metal bellows system due to the liquid's thermal expansion. The movement of the bellows varies the gas reservoir volume and leads to a corresponding change of the condensation area of the heat pipe. With methanol as the heat pipe working fluid and perfluoro-n-pentane as the auxiliary liquid, the control capability was found to be T sub s = 31.5 + or - 1.5 C in a power range from 3 to 30 W, compared to T sub s = 33 + or - 3 C with methanol as auxiliary liquid. The change in T sub s was 35 + or - 5.5 C with the bellows held in the closed position.

  13. Two step meso-acidophilic bioleaching of chalcopyrite containing ball mill spillage and removal of the surface passivation layer.

    PubMed

    Panda, S; Parhi, P K; Nayak, B D; Pradhan, N; Mohapatra, U B; Sukla, L B

    2013-02-01

    Meso-acidophilic bacterial leaching of ball mill spillage (containing chalcopyrite >80%) was carried out in an innovative two-step bioleaching method. The major drawback of meso-acidophilic bioleaching limiting industrial application is the passivation phenomenon over the ore surfaces in iron-sulfur rich environments. In the present study, we present a novel wash solution that efficiently removed the passivation layer. FTIR characterization of the bioleached sample indicated that the residues could be further leached to recover extra copper after wash solution application. XRD study indicated accumulation of sulfates (SO(4)(-)) of Na, K, Fe and oxy hydroxides of iron [FeO(OH)] in the form of jarosite outlining the passivation layer. SEM, FESEM-EDS studies indicated severe corrosion effects of the wash solution on the passivation layer. Two step bioleaching of the ore sample yielded 32.6% copper in 68days in the first interlude and post wash solution application yielded 10.8% additional copper.

  14. Condensate removal mechanisms in a constrained vapor bubble heat exchanger.

    PubMed

    Zheng, Ling; Wang, Yingxin; Wayner, Peter C; Plawsky, Joel L

    2002-10-01

    Microgravity experiments on the constrained vapor bubble heat exchanger (CVB) are being developed for the space station. Herein, ground-based experimental studies on condensate removal in the condenser region of the vertical CVB were conducted and the mechanism of condensate removal in microgravity was found to be the capillary force. The effects of curvature and contact angle on the driving forces for condensate removal is studied. The Nusselt correlations are derived for the film condensation and the flow from the drop to the meniscus at the moment of merging. These new correlations scale as forced convection with h proportional to L(1/2) or h proportional to L(1/2)(cd). For the partially wetting ethanol system studied, the heat transfer coefficient for film condensation was found to be 4.25 x 10(4) W/m(2)K; for dropwise condensation at moment of merging it was found to be 9.64 x 10(4) W/m(2)K; and for single drops it was found to be 1.33 x 10(5) W/m(2)K.

  15. Temperature and blood flow distribution in the human leg during passive heat stress

    PubMed Central

    Chiesa, Scott T.; Trangmar, Steven J.

    2016-01-01

    The influence of temperature on the hemodynamic adjustments to direct passive heat stress within the leg's major arterial and venous vessels and compartments remains unclear. Fifteen healthy young males were tested during exposure to either passive whole body heat stress to levels approaching thermal tolerance [core temperature (Tc) + 2°C; study 1; n = 8] or single leg heat stress (Tc + 0°C; study 2; n = 7). Whole body heat stress increased perfusion and decreased oscillatory shear index in relation to the rise in leg temperature (Tleg) in all three major arteries supplying the leg, plateauing in the common and superficial femoral arteries before reaching severe heat stress levels. Isolated leg heat stress increased arterial blood flows and shear patterns to a level similar to that obtained during moderate core hyperthermia (Tc + 1°C). Despite modest increases in great saphenous venous (GSV) blood flow (0.2 l/min), the deep venous system accounted for the majority of returning flow (common femoral vein 0.7 l/min) during intense to severe levels of heat stress. Rapid cooling of a single leg during severe whole body heat stress resulted in an equivalent blood flow reduction in the major artery supplying the thigh deep tissues only, suggesting central temperature-sensitive mechanisms contribute to skin blood flow alone. These findings further our knowledge of leg hemodynamic responses during direct heat stress and provide evidence of potentially beneficial vascular alterations during isolated limb heat stress that are equivalent to those experienced during exposure to moderate levels of whole body hyperthermia. PMID:26823344

  16. Preliminary model for heat transport within a tongue-and-reservoir liquid diode for passive solar heating

    SciTech Connect

    Jones, G.F.

    1984-01-01

    A preliminary model is presented for heat transport within a tongue-and-reservoir liquid diode for passive solar heating. The diode consists of a rectangular vertical slot (tongue) extending from the bottom of a rectangular-shaped reservoir at the reservoir's front face. Water is used as the working fluid in the tongue and reservoir. Solar radiation is incident on the front face of the tongue, which also loses heat to the outside, while radiation and convection transport heat from the back of the reservoir to the building. Convection transports heat when the tongue is irradiated; however, when convection ceases and the temperature of the tongue cools below that of the reservoir (from exposure to the outside temperature), the reservoir stratifies, and the primary heat loss mechanism is conduction through the tongue and its fluid. The result is a passive solar component that may outperform most others. Flow in the tongue is treated as boundary layer flow; the integral forms of the governing equations are combined to form a single equation governing the local boundary layer thickness. The results are shown to depend upon the Grashof, Prandtl, and heat-loss Biot numbers. Results from this model agree well with those from our flow visualization experiments. A model is also proposed for diode heat transport processes during cool-down. In this model, and empirical coefficient accounts for the weak convective mixing that occurs in the reservoir during this phase. Preliminary results indicate the coefficient to be spatially dependent but independent of time and reservoir temperature. More experiments are planned to further validate both of the models described above.

  17. Liquid metal cooled nuclear reactors with passive cooling system

    DOEpatents

    Hunsbedt, Anstein; Fanning, Alan W.

    1991-01-01

    A liquid metal cooled nuclear reactor having a passive cooling system for removing residual heat resulting from fuel decay during reactor shutdown. The passive cooling system comprises a plurality of cooling medium flow circuits which cooperate to remove and carry heat away from the fuel core upon loss of the normal cooling flow circuit to areas external thereto.

  18. Kinetics of soluble chromium removal from contaminated water by zerovalent iron media: corrosion inhibition and passive oxide effects.

    PubMed

    Melitas, N; Chuffe-Moscoso, O; Farrell, J

    2001-10-01

    Permeable reactive barriers containing zerovalent iron are being increasingly employed for in situ remediation of groundwater contaminated with redox active metals and chlorinated organic compounds. This research investigated the effect of chromate concentration on its removal from solution by zerovalent iron. Removal rates of aqueous Cr(VI) by iron wires were measured in batch experiments for initial chromium concentrations ranging from 100 to 10 000 microg/L. Chromate removal was also measured in columns packed with zerovalent iron filings over this same concentration range. Electrochemical measurements were made to determine the free corrosion potential and corrosion rate of the iron reactants. In both the batch and column reactors, absolute rates of chromium removal declined with increasing chromate concentration. Corrosion current measurements indicated that the rate of iron corrosion decreased with increasing Cr(VI) concentrations between 0 and 5000 microg/L. At a Cr(VI) concentration of 10 000 microg/L, Tafel polarization diagrams showed that chromium removal was affected by its diffusion rate through a passivating oxide film and by the ability of iron to release Fe2+ at anodic sites. In contrast, water reduction was not mass transfer limited, but chromium did decrease the exchange current for the hydrogen evolution reaction. Even at the most passivating concentration of 10 000 microng/L, effluent Cr(VI) concentrations in the column reactors reached a steady state, indicating that passivation had also reached a steady state. Although chromate contributes to iron surface passivation, the removal rates are still sufficiently fast for in situ iron barriers to be effective for Cr(VI) removal at most environmentally relevant concentrations.

  19. System Study: Residual Heat Removal 1998–2013

    SciTech Connect

    Schroeder, John Alton

    2015-02-01

    This report presents an unreliability evaluation of the residual heat removal (RHR) system in two modes of operation (low-pressure injection in response to a large loss-of-coolant accident and post-trip shutdown-cooling) at 104 U.S. commercial nuclear power plants. Demand, run hours, and failure data from fiscal year 1998 through 2013 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10-year period while yearly estimates for system unreliability are provided for the entire active period. No statistically significant trends were identified in the RHR results.

  20. Methods of Helium Injection and Removal for Heat Transfer Augmentation

    NASA Technical Reports Server (NTRS)

    Haight, Harlan; Kegley, Jeff; Bourdreaux, Meghan

    2008-01-01

    While augmentation of heat transfer from a test article by helium gas at low pressures is well known, the method is rarely employed during space simulation testing because the test objectives usually involve simulation of an orbital thermal environment. Test objectives of cryogenic optical testing at Marshall Space Flight Center's X-ray Cryogenic Facility (XRCF) have typically not been constrained by orbital environment parameters. As a result, several methods of helium injection have been utilized at the XRCF since 1999 to decrease thermal transition times. A brief synopsis of these injection (and removal) methods including will be presented.

  1. Methods of Helium Injection and Removal for Heat Transfer Augmentation

    NASA Technical Reports Server (NTRS)

    Kegley, Jeffrey

    2008-01-01

    While augmentation of heat transfer from a test article by helium gas at low pressures is well known, the method is rarely employed during space simulation testing because the test objectives are to simulate an orbital thermal environment. Test objectives of cryogenic optical testing at Marshall Space Flight Center's X-ray Calibration Facility (XRCF) have typically not been constrained by orbital environment parameters. As a result, several methods of helium injection have been utilized at the XRCF since 1999 to decrease thermal transition times. A brief synopsis of these injection (and removal) methods including will be presented.

  2. Effect of passive heat stress on arterial stiffness in smokers versus non-smokers

    NASA Astrophysics Data System (ADS)

    Moyen, N. E.; Ganio, M. S.; Burchfield, J. M.; Tucker, M. A.; Gonzalez, M. A.; Dougherty, E. K.; Robinson, F. B.; Ridings, C. B.; Veilleux, J. C.

    2016-04-01

    In non-smokers, passive heat stress increases shear stress and vasodilation, decreasing arterial stiffness. Smokers, who reportedly have arterial dysfunction, may have similar improvements in arterial stiffness with passive heat stress. Therefore, we examined the effects of an acute bout of whole-body passive heat stress on arterial stiffness in smokers vs. non-smokers. Thirteen smokers (8.8 ± 5.5 [median = 6] cigarettes per day for >4 years) and 13 non-smokers matched for age, mass, height, and exercise habits (27 ± 8 years; 78.8 ± 15.4 kg; 177.6 ± 6.7 cm) were passively heated to 1.5 °C core temperature ( T C) increase. At baseline and each 0.5 °C T C increase, peripheral (pPWV) and central pulse wave velocity (cPWV) were measured via Doppler ultrasound. No differences existed between smokers and non-smokers for any variables (all p > 0.05), except cPWV slightly increased from baseline (526.7 ± 81.7 cm · s-1) to 1.5 °C Δ T C (579.7 ± 69.8 cm · s-1; p < 0.005), suggesting heat stress acutely increased central arterial stiffness. pPWV did not change with heating (grand mean: baseline = 691.9 ± 92.9 cm · s-1; 1.5 °C Δ T C = 691.9 ± 79.5 cm · s-1; p > 0.05). Changes in cPWV and pPWV during heating correlated ( p < 0.05) with baseline PWV in smokers (cPWV: r = -0.59; pPWV: r = -0.62) and non-smokers (cPWV: r = -0.45; pPWV: r = -0.77). Independent of smoking status, baseline stiffness appears to mediate the magnitude of heating-induced changes in arterial stiffness.

  3. Passivation of organic light emitting diode anode grid lines by pulsed Joule heating

    NASA Astrophysics Data System (ADS)

    Janka, M.; Gierth, R.; Rubingh, J.-E.; Abendroth, M.; Eggert, M.; Moet, D. J. D.; Lupo, D.

    2015-09-01

    We report the self-aligned passivation of a current distribution grid for an organic light emitting diode (OLED) anode using a pulsed Joule heating method to align the passivation layer accurately on the metal grid. This method involves passing an electric current through the grid to cure a polymer dielectric. Uncured polymer is then rinsed away, leaving a patterned dielectric layer that conforms to the shape of the grid lines. To enhance the accuracy of the alignment, heat conduction into the substrate and the transparent electrode is limited by using short current pulses instead of a constant current. Excellent alignment accuracy of the dielectric layer on printed metal grid lines has been achieved, with a typical 4-μm dielectric overhang. In addition to good accuracy, pulsed Joule heating significantly cuts down process time and energy consumption compared to heating with a constant current. The feasibility of using a printed current distribution grid and Joule heating was demonstrated in an OLED device.

  4. Energy-conserving passive solar multi-family retrofit projects. Cycle 5, category 1: HUD Solar Heating and Cooling Demonstration Program

    NASA Astrophysics Data System (ADS)

    1981-10-01

    A total of 14 passive solar retrofit buildings are described. The concept of passive solar energy and the various types of passive systems found in the Cycle 5 projects are discussed. Each of the 14 solar designs is described, and some of the key points raised in the discussion of passive concepts are illustrated. Each project description cites the location of the passive solar home and presents the following information: grantee/builder, designer, solar designer, price, number of units, net heated area, heat load, degree days, solar fraction of the total heat load, and auxiliary heat required. Project descriptions also include data on recognition factors (the five passive elements necessary for a complete passive system), the type of auxiliary heating system used in the building, the solar water heating system (if any), and the passive cooling techniques used (if any).

  5. Tritium Removal by Laser Heating and Its Application to Tokamaks

    SciTech Connect

    C.H. Skinner; C.A. Gentile; G. Guttadora; A. Carpe; S. Langish; K.M. Young; M. Nishi; W. Shu

    2001-11-16

    A novel laser heating technique has recently been applied to removing tritium from carbon tiles that had been exposed to deuterium-tritium (DT) plasmas in the Tokamak Test Fusion Reactor (TFTR). A continuous wave neodymium laser, of power up to 300 watts, was used to heat the surface of the tiles. The beam was focused to an intensity, typically 8 kW/cm{sup 2}, and rapidly scanned over the tile surface by galvanometer-driven scanning mirrors. Under the laser irradiation, the surface temperature increased dramatically, and temperatures up to 2,300 degrees C were recorded by an optical pyrometer. Tritium was released and circulated in a closed-loop system to an ionization chamber that measured the tritium concentration. Most of the tritium (up to 84%) could be released by the laser scan. This technique appears promising for tritium removal in a next-step DT device as it avoids oxidation, the associated deconditioning of the plasma facing surfaces, and the expense of processing large quantities of tritium oxide. Some engineering aspects of the implementation of this method in a next-step fusion device will be discussed.

  6. Evaluation of a Passive Heat Exchanger Based Cooling System for Fuel Cell Applications

    NASA Technical Reports Server (NTRS)

    Colozza, Anthony J.; Burke, Kenneth A.

    2011-01-01

    Fuel cell cooling is conventionally performed with an actively controlled, dedicated coolant loop that exchanges heat with a separate external cooling loop. To simplify this system the concept of directly cooling a fuel cell utilizing a coolant loop with a regenerative heat exchanger to preheat the coolant entering the fuel cell with the coolant exiting the fuel cell was analyzed. The preheating is necessary to minimize the temperature difference across the fuel cell stack. This type of coolant system would minimize the controls needed on the coolant loop and provide a mostly passive means of cooling the fuel cell. The results indicate that an operating temperature of near or greater than 70 C is achievable with a heat exchanger effectiveness of around 90 percent. Of the heat exchanger types evaluated with the same type of fluid on the hot and cold side, a counter flow type heat exchanger would be required which has the possibility of achieving the required effectiveness. The number of heat transfer units required by the heat exchanger would be around 9 or greater. Although the analysis indicates the concept is feasible, the heat exchanger design would need to be developed and optimized for a specific fuel cell operation in order to achieve the high effectiveness value required.

  7. Combined Active and Passive Solar Space Heating and Solar Hot Water Systems for an Elementary School in Boise, Idaho.

    ERIC Educational Resources Information Center

    Smull, Neil A.; Armstrong, Gerald L.

    1979-01-01

    Amity Elementary School in Boise, Idaho, features a solar space heating and domestic hot water system along with an earth covering to accommodate the passive aspects of energy conservation. (Author/MLF)

  8. Cleaning and passivation of copper surfaces to remove surface radioactivity and prevent oxide formation

    SciTech Connect

    Hoppe, Eric W.; Seifert, Allen; Aalseth, Craig E.; Bachelor, Paula P.; Day, Anthony R.; Edwards, Danny J.; Hossbach, Todd W.; Litke, Kevin E.; McIntyre, Justin I.; Miley, Harry S.; Schulte, Shannon M.; Smart, John E.; Warren, Glen A.

    2007-08-21

    High-purity copper is an attractive material for constructing ultra-low-background radiation measurement devices. Many low-background experiments using high-purity copper have indicated surface contamination emerges as the dominant background. Radon daughters plate out on exposed surfaces, leaving a residual 210Pb background that is difficult to avoid. Dust is also a problem; even under cleanroom conditions, the amount of U and Th deposited on surfaces can represent the largest remaining background. To control these backgrounds, a copper cleaning chemistry has been developed. Designed to replace an effective, but overly aggressive concentrated nitric acid etch, this peroxide-based solution allows for a more controlled cleaning of surfaces. The acidified hydrogen peroxide solution will generally target the Cu+/Cu2+ species which are the predominant surface participants, leaving the bulk of copper metal intact. This preserves the critical tolerances of parts and eliminates significant waste disposal issues. Accompanying passivation chemistry has also been developed that protects copper surfaces from oxidation. Using a high-activity polonium surface spike, the most difficult-to-remove daughter isotope of radon, the performance of these methods are quantified. © 2001 Elsevier Science. All rights reserved

  9. Effect of short-term exercise-heat acclimation on ventilatory and cerebral blood flow responses to passive heating at rest in humans.

    PubMed

    Fujii, Naoto; Tsuji, Bun; Honda, Yasushi; Kondo, Narihiko; Nishiyasu, Takeshi

    2015-09-01

    Hyperthermia induces hyperventilation and cerebral hypoperfusion in resting humans. We tested the hypothesis that short-term exercise-heat acclimation would alleviate those effects. Twenty healthy male subjects were divided into two groups that performed exercise training in the heat (TR-HEAT, n = 10) or cold (TR-COLD, n = 10). Before and after the training, the subjects in both groups participated in passive-heat tests at rest. Training was performed at 37°C (TR-HEAT) or 10°C (TR-COLD) and entailed four 20-min bouts of cycling at 50% peak oxygen uptake separated by 10-min recoveries daily for 6 consecutive days. After TR-HEAT, esophageal temperature was lowered when measured before and during passive heating, as was the esophageal temperature threshold for cutaneous active vasodilation, whereas plasma volume was increased (all P < 0.05). These traditional indices of successful heat acclimation were not all induced by TR-COLD (all P > 0.05). TR-HEAT had no significant effect on passive heating-induced increases in minute ventilation, even when evaluated as the esophageal temperature threshold for increases in minute ventilation and the slope relating minute ventilation to esophageal temperature (all P > 0.05). By contrast, TR-HEAT attenuated the passive heating-induced reduction in the cerebral vascular conductance index (middle cerebral artery mean blood velocity/mean arterial pressure) (all P < 0.05). TR-COLD did not attenuate the increase in minute ventilation or the decrease in the cerebral vascular conductance index observed during passive heating (all P > 0.05). These data suggest that in resting heated humans, short-term heat acclimation achieved through moderate-intensity exercise training (i.e., 50% peak oxygen uptake) in the heat does not influence hyperthermia-induced hyperventilation, but it does potentially attenuate cerebral hypoperfusion.

  10. Method for passive cooling liquid metal cooled nuclear reactors, and system thereof

    DOEpatents

    Hunsbedt, Anstein; Busboom, Herbert J.

    1991-01-01

    A liquid metal cooled nuclear reactor having a passive cooling system for removing residual heat resulting from fuel decay during reactor shutdown. The passive cooling system comprises a plurality of partitions surrounding the reactor vessel in spaced apart relation forming intermediate areas for circulating heat transferring fluid which remove and carry away heat from the reactor vessel.

  11. Advanced phase change materials and systems for solar passive heating and cooling of residential buildings

    SciTech Connect

    Salyer, I.O.; Sircar, A.K.; Dantiki, S.

    1988-01-01

    During the last three years under the sponsorship of the DOE Solar Passive Division, the University of Dayton Research Institute (UDRI) has investigated four phase change material (PCM) systems for utility in thermal energy storage for solar passive heating and cooling applications. From this research on the basis of cost, performance, containment, and environmental acceptability, we have selected as our current and most promising series of candidate phase change materials, C-15 to C-24 linear crystalline alkyl hydrocarbons. The major part of the research during this contract period was directed toward the following three objectives. Find, test, and develop low-cost effective phase change materials (PCM) that melt and freeze sharply in the comfort temperature range of 73--77{degree}F for use in solar passive heating and cooling of buildings. Define practical materials and processes for fire retarding plasterboard/PCM building products. Develop cost-effective methods for incorporating PCM into building construction materials (concrete, plasterboard, etc.) which will lead to the commercial manufacture and sale of PCM-containing products resulting in significant energy conservation.

  12. Passive Gas-Gap Heat Switches for Use in Adiabatic Demagnetization Refrigerators

    NASA Technical Reports Server (NTRS)

    Shirron, P. J.; Canavan, E. R.; DiPirro, M. J.; Jackson, M.; Panek, J.; Tuttle, J. G.; Krebs, Carolyn (Technical Monitor)

    2001-01-01

    We have designed, built, and tested a gas gap heat switch that works passively, without the need for a separate, thermally activated getter. This switch uses He-3 condensed as a thin film on alternating plates of copper. The switch is thermally conductive at temperatures above about 0.2 K, and is insulating if either end of the switch is below about 0.15 K. The "on" conductance (7 mW/K at 0.25K) is limited by the surface area and gap between the copper leaves, the saturated vapor pressure of the He-3, and the Kapitza boundary resistance between the He-3 and the copper. The "off" conductance is determined by the helium containment shell which physically supports the two conductive ends. We have also designed and are building passive gas gap heat switches which will passively turn off near 1 K and 4 K. For these switches we rely on the rapidly changing vapor pressure of He-4 above neon or copper substrates, respectively, when the coverage is less than one monolayer. The different binding energies of the He-4 to the neon or copper give rise to the different temperatures where the switches transition between the on and off states.

  13. Baroreceptor unloading does not limit forearm sweat rate during severe passive heat stress.

    PubMed

    Schlader, Zachary J; Gagnon, Daniel; Lucas, Rebekah A I; Pearson, James; Crandall, Craig G

    2015-02-15

    This study tested the hypothesis that sweat rate during passive heat stress is limited by baroreceptor unloading associated with heat stress. Two protocols were performed in which healthy subjects underwent passive heat stress that elicited an increase in intestinal temperature of ∼1.8°C. Upon attaining this level of hyperthermia, in protocol 1 (n = 10, 3 females) a bolus (19 ml/kg) of warm (∼38°C) isotonic saline was rapidly (5-10 min) infused intravenously to elevate central venous pressure (CVP), while in protocol 2 (n = 11, 5 females) phenylephrine was infused intravenously (60-120 μg/min) to return mean arterial pressure (MAP) to normothermic levels. In protocol 1, heat stress reduced CVP from 3.9 ± 1.9 mmHg (normothermia) to -0.6 ± 1.4 mmHg (P < 0.001), while saline infusion returned CVP to normothermic levels (5.1 ± 1.7 mmHg; P > 0.999). Sweat rate was elevated by heat stress (1.21 ± 0.44 mg·cm(-2)·min(-1)) but remained unchanged during rapid saline infusion (1.26 ± 0.47 mg·cm(-2)·min(-1), P = 0.5), whereas cutaneous vascular conductance increased from 77 ± 10 to 101 ± 20% of local heating max (P = 0.029). In protocol 2, MAP was reduced with heat stress from 85 ± 7 mmHg to 76 ± 8 mmHg (P = 0.048). Although phenylephrine infusion returned MAP to normothermic levels (88 ± 7 mmHg; P > 0.999), sweat rate remained unchanged during phenylephrine infusion (1.39 ± 0.22 vs. 1.41 ± 0.24 mg·cm(-2)·min(-1); P > 0.999). These data indicate that both cardiopulmonary and arterial baroreceptor unloading do not limit increases in sweat rate during passive heat stress.

  14. Enhancing ultra-high CPV passive cooling using least-material finned heat sinks

    NASA Astrophysics Data System (ADS)

    Micheli, Leonardo; Fernandez, Eduardo F.; Almonacid, Florencia; Reddy, K. S.; Mallick, Tapas K.

    2015-09-01

    Ultra-high concentrating photovoltaic (CPV) systems aim to increase the cost-competiveness of CPV by increasing the concentrations over 2000 suns. In this work, the design of a heat sink for ultra-high concentrating photovoltaic (CPV) applications is presented. For the first time, the least-material approach, widely used in electronics to maximize the thermal dissipation while minimizing the weight of the heat sink, has been applied in CPV. This method has the potential to further decrease the cost of this technology and to keep the multijunction cell within the operative temperature range. The designing procedure is described in the paper and the results of a thermal simulation are shown to prove the reliability of the solution. A prediction of the costs is also reported: a cost of 0.151/Wp is expected for a passive least-material heat sink developed for 4000x applications.

  15. Enhancing ultra-high CPV passive cooling using least-material finned heat sinks

    SciTech Connect

    Micheli, Leonardo Mallick, Tapas K.; Fernandez, Eduardo F.; Almonacid, Florencia; Reddy, K. S.

    2015-09-28

    Ultra-high concentrating photovoltaic (CPV) systems aim to increase the cost-competiveness of CPV by increasing the concentrations over 2000 suns. In this work, the design of a heat sink for ultra-high concentrating photovoltaic (CPV) applications is presented. For the first time, the least-material approach, widely used in electronics to maximize the thermal dissipation while minimizing the weight of the heat sink, has been applied in CPV. This method has the potential to further decrease the cost of this technology and to keep the multijunction cell within the operative temperature range. The designing procedure is described in the paper and the results of a thermal simulation are shown to prove the reliability of the solution. A prediction of the costs is also reported: a cost of 0.151$/W{sub p} is expected for a passive least-material heat sink developed for 4000x applications.

  16. System Study: Residual Heat Removal 1998-2014

    SciTech Connect

    Schroeder, John Alton

    2015-12-01

    This report presents an unreliability evaluation of the residual heat removal (RHR) system in two modes of operation (low-pressure injection in response to a large loss-of-coolant accident and post-trip shutdown-cooling) at 104 U.S. commercial nuclear power plants. Demand, run hours, and failure data from fiscal year 1998 through 2014 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10 year period, while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing trends were identified in the RHR results. A highly statistically significant decreasing trend was observed for the RHR injection mode start-only unreliability. Statistically significant decreasing trends were observed for RHR shutdown cooling mode start-only unreliability and RHR shutdown cooling model 24-hour unreliability.

  17. The use of segregated heat sink structures to achieve enhanced passive cooling for outdoor wireless devices

    NASA Astrophysics Data System (ADS)

    O'Flaherty, K.; Punch, J.

    2014-07-01

    Environmental standards which govern outdoor wireless equipment can stipulate stringent conditions: high solar loads (up to 1 kW/m2), ambient temperatures as high as 55°C and negligible wind speeds (0 m/s). These challenges result in restrictions on power dissipation within a given envelope, due to the limited heat transfer rates achievable with passive cooling. This paper addresses an outdoor wireless device which features two segregated heat sink structures arranged vertically within a shielded chimney structure: a primary sink to cool temperature-sensitive components; and a secondary sink for high power devices. Enhanced convective cooling of the primary sink is achieved due to the increased mass flow within the chimney generated by the secondary sink. An unshielded heat sink was examined numerically, theoretically and experimentally, to verify the applicability of the methods employed. Nusselt numbers were compared for three cases: an unshielded heat sink; a sink located at the inlet of a shield; and a primary heat sink in a segregated structure. The heat sink, when placed at the inlet of a shield three times the length of the sink, augmented the Nusselt number by an average of 64% compared to the unshielded case. The Nusselt number of the primary was found to increase proportionally with the temperature of the secondary sink, and the optimum vertical spacing between the primary and secondary sinks was found to be close to zero, provided that conductive transfer between the sinks was suppressed.

  18. Passivation of silicon surfaces by heat treatment in liquid water at 110 °C

    NASA Astrophysics Data System (ADS)

    Nakamura, Tomohiko; Sameshima, Toshiyuki; Hasumi, Masahiko; Mizuno, Tomohisa

    2015-10-01

    We report the effective passivation of silicon surfaces by heating single-crystalline silicon substrates in liquid water at 110 °C for 1 h. High photo-induced effective minority carrier lifetimes τeff were obtained ranging from 8.3 × 10-4 to 3.1 × 10-3 s and from 1.2 × 10-4 to 6.0 × 10-4 s for the n- and p-type samples, respectively, under 635 nm light illumination, while the τeff values of the initial bare samples were lower than 1.2 × 10-5 s. The heat treatment in liquid water at 110 °C for 1 h resulted in low surface recombination velocities ranging from 7 to 34 cm/s and from 49 to 250 cm/s for the n- and p-type samples, respectively. The photo-conductivity of the n-type sample was increased from 3.8 × 10-3 (initial) to 1.4 × 10-1 S/cm by the present heat treatment under air-mass (AM) 1.5 light illumination at 100 mW/cm2. The thickness of the passivation layer was estimated to be only approximately 0.7 nm. Metal-insulator-semiconductor-type solar cells were demonstrated with Al and Au metal formation on the passivated surface. Rectified current voltage and solar cell characteristics were observed. The open circuit voltages were obtained to be 0.52 and 0.49 V under AM 1.5 light illumination at 100 mW/cm2 for the n- and p-type samples, respectively.

  19. Simulations of polarization dependent contrast during the diurnal heating cycle for passive millimeter-wave imagery

    NASA Astrophysics Data System (ADS)

    Wilson, John P.; Murakowski, Maciej; Schuetz, Christopher A.; Prather, Dennis W.

    2013-09-01

    Passive millimeter-wave (mmW) sensors are especially suited to persistent surveillance applications due to their ability to operate during day/night conditions and through transient atmospheric obscurants such as clouds, rain and fog. The contrast of targets will change throughout a diurnal heating cycle and this change will be polarization dependent. Simulations are presented from a ray tracing program developed for the mmW regime that has been modified to account for polarization information. Results are shown demonstrating periods during the day when the contrast of certain targets drop to zero for a linear polarization state while the orthogonal state still maintains a high contrast.

  20. Mathematical modeling of heat and mass transfer in a passive autocatalytic recombiner

    NASA Astrophysics Data System (ADS)

    Anpilov, S. V.; Grigoruk, D. G.; Kondratenko, P. S.; Khristenko, E. B.; Chizhov, M. E.

    2013-11-01

    A mathematical model of heat and mass transfer in a passive autocatalytic recombiner (PAR) is developed. Three-dimensional calculations of convection of a hydrogen-containing medium in a hydrogen recombiner of the RVK-315 model series are performed using the ANSYS Fluent commercial code. Due to the periodic structure of the catalytic block, calculations were performed for one rod arranged in its middle. The results of calculations are correlated with the experimental data acquired using the OAO VTI stand. The mismatch between the calculated and experimental data does not exceed 30% in the range of bulk hydrogen concentrations of 1.5-6.5%.

  1. Analysis of a passive heat sink for temperature stabilization of high-power LED bulbs

    NASA Astrophysics Data System (ADS)

    Balvís, Eduardo; Bendaña, Ricardo; Michinel, Humberto; Fernández de Córdoba, Pedro; Paredes, Angel

    2015-04-01

    In this paper we present a numerical analysis and experimental measurements of the temperature stabilization of high-power LED chips that we have obtained by employing an aluminum passive heat sink, designed to be used in a compact light bulb configuration. We demonstrate that our system keeps the temperature of the LED chip well-below 70° C yielding long-term operation of the device. Our simulations have been performed for a low-cost device ready to install in public streetlights. The experimental measurements performed in different configurations show a nice agreement with the numerical calculations.

  2. Metal Removal Efficiency And Ecotoxicological Assessment Of Field-Scale Passive Treatment Biochemical Reactors

    EPA Science Inventory

    Anaerobic biochemical reactors (BCRs) are useful for removing metals from mining-impacted water at remote sites. Removal processes include sorption and precipitation of metal sulfides, carbonates, and hydroxides. A question of interest is whether BCRs remove aquatic toxicity. ...

  3. Metal removal efficiency and ecotoxicological assessment of field-scale passive treatment biochemical reactors

    EPA Science Inventory

    Anaerobic biochemical reactors (BCRs) are useful for removing metals from mining-impacted water (MIW) at remote sites. Removal processes include sorption and precipitation of metal sulfides, carbonates and hydroxides. A question of interest is whether BCRs remove aquatic toxicit...

  4. Passive body heating improves sleep patterns in female patients with fibromyalgia

    PubMed Central

    Silva, Andressa; de Queiroz, Sandra Souza; Andersen, Monica Levy; Mônico-Neto, Marcos; da Silveira Campos, Raquel Munhoz; Roizenblatt, Suely; Tufik, Sergio; de Mello, Marco Túlio

    2013-01-01

    OBJECTIVE: To assess the effect of passive body heating on the sleep patterns of patients with fibromyalgia. METHODS: Six menopausal women diagnosed with fibromyalgia according to the criteria determined by the American College of Rheumatology were included. All women underwent passive immersion in a warm bath at a temperature of 36±1°C for 15 sessions of 30 minutes each over a period of three weeks. Their sleep patterns were assessed by polysomnography at the following time-points: pre-intervention (baseline), the first day of the intervention (acute), the last day of the intervention (chronic), and three weeks after the end of the intervention (follow-up). Core body temperature was evaluated by a thermistor pill during the baseline, acute, chronic, and follow-up periods. The impact of this treatment on fibromyalgia was assessed via a specific questionnaire termed the Fibromyalgia Impact Questionnaire. RESULTS: Sleep latency, rapid eye movement sleep latency and slow wave sleep were significantly reduced in the chronic and acute conditions compared with baseline. Sleep efficiency was significantly increased during the chronic condition, and the awakening index was reduced at the chronic and follow-up time points relative to the baseline values. No significant differences were observed in total sleep time, time in sleep stages 1 or 2 or rapid eye movement sleep percentage. The core body temperature and Fibromyalgia Impact Questionnaire responses did not significantly change over the course of the study. CONCLUSION: Passive body heating had a positive effect on the sleep patterns of women with fibromyalgia. PMID:23525306

  5. An analysis of manganese as an indicator for heavy metal removal in passive treatment using laboratory spent mushroom compost columns

    SciTech Connect

    Jacobson, B.A.; Unz, R.F.; Dempsey, B.A.

    1999-07-01

    The National Pollution Discharge Elimination System (NPDES) dictates removal of manganese in mine drainage to less than 4 mg/1 daily or less than 2 mg/1 on a monthly average. Owing to its high solubility at low and circumneutral pH, removal of manganese is often the most difficult of the NPDES discharge standards. This has lead to the use of Mn(II) as a surrogate for metal removal. However, recent studies concluded that zinc or nickel may be more appropriate indicators for removal of other metals. Previous field studies showed zinc removal to be highly correlated to the removal of copper, cobalt, and nickel in a sulfate reducing subsurface loaded wetland, whereas manganese removal was poorly correlated. The objective of this study was to evaluate zinc and manganese retention under sulfate reducing conditions in bench scale columns containing fresh spent mushroom compost. Column effluent data were analyzed using an EPA geochemical computer model (MINTEQ) over the pH range of 6.0 to 6.8. Under these conditions, zinc and manganese displayed distinctly reactivities. Zn(II) was supersaturated with respect to ZnS{sub s} and the Zn(HS){sub 2}{degree} and Zn(HS){sub 3}{sup minus} complexes dominated solubility. Soluble zinc concentrations were inversely correlated to sulfide. Mn(II) remained as soluble Mn{sup +2}. During early column operation at pH > 7, MnCO{sup 3(s)} was supersaturated. Manganese concentrations did not correlate with pH or sulfide. Given these fundamental differences in removal mechanisms between Zn and Mn under sulfate reducing conditions, the use of manganese removal as a surrogate for heavy metal removal in passive treatment of mine drainage seems unjustified.

  6. Design and Test of Passively Operated Heat Switches for 0.2 to 15 K

    NASA Technical Reports Server (NTRS)

    DiPirro, M. J.; Shirron, P. J.; Canavan, E. R.; Francis, J. J.; Tuttle, J. G.

    2003-01-01

    Heat switches have many uses in cryogenics, from regulating heat flow between refrigeration stages to thermally isolating components once they have cooled to low temperature. Among the techniques one can use for thermal switching, the gas-gap technique has the advantages of wide operating temperature range, high switching ratio, and no moving parts. The traditional gas-gap switch uses copper conductors separated by a small gap and an external getter. The switch is activated by heating and cooling the getter by moving gas into and out of the gap, turning the switch on and off. We have designed, built and tested heat switches that use an internal getter to passively turn off at temperatures between 0.2 and 15 K. The getter is thermally anchored to one side of the switch, and when that side of the switch cools through a transition region, gas adsorbs onto the getter and the switch turns off. The challenges are to make the transition region very narrow and tailorable to a wide range of applications, and to achieve high gas conductance when the switch is on. We have made switches using He-3, He-4, hydrogen, and neon gas, and have used charcoal and various metal substrates as getters. Switching ratios range from 1000 to over 10,000. Design and performance of these switches will be discussed in detail.

  7. Heat Removal from Bipolar Transistor by Loop Heat Pipe with Nickel and Copper Porous Structures

    PubMed Central

    Smitka, Martin; Malcho, Milan

    2014-01-01

    Loop heat pipes (LHPs) are used in many branches of industry, mainly for cooling of electrical elements and systems. The loop heat pipe is a vapour-liquid phase-change device that transfers heat from evaporator to condenser. One of the most important parts of the LHP is the porous wick structure. The wick structure provides capillary force to circulate the working fluid. To achieve good thermal performance of LHP, capillary wicks with high permeability and porosity and fine pore radius are expected. The aim of this work was to develop porous structures from copper and nickel powder with different grain sizes. For experiment copper powder with grain size of 50 and 100 μm and nickel powder with grain size of 10 and 25 μm were used. Analysis of these porous structures and LHP design are described in the paper. And the measurements' influences of porous structures in LHP on heat removal from the insulated gate bipolar transistor (IGBT) have been made. PMID:24959622

  8. Grouping of light water reactors for evaluation of decay heat removal capability

    SciTech Connect

    Karol, R.; Fresco, A.; Perkins, K.R.

    1984-06-01

    This grouping report provides a compilation of decay heat removal systems (DHRS) data for operating commercial light water reactors. The reactors have been divided into 12 groups based on similarity of the DHRS and related systems as part of the NRC Task Action Plan on Shutdown Decay Heat Removal Requirements.

  9. Alternatives Generation and Analysis for Heat Removal from High Level Waste Tanks

    SciTech Connect

    WILLIS, W.L.

    2000-06-15

    This document addresses the preferred combination of design and operational configurations to provide heat removal from high-level waste tanks during Phase 1 waste feed delivery to prevent the waste temperature from exceeding tank safety requirement limits. An interim decision for the preferred method to remove the heat from the high-level waste tanks during waste feed delivery operations is presented herein.

  10. Results from evaporation tests to support the MWTF heat removal system design

    SciTech Connect

    Crea, B.A.

    1994-12-22

    An experimental tests program was conducted to measure the evaporative heat removal from the surface of a tank of simulated waste. The results contained in this report constitute definition design data for the latest heat removal function of the MWTF primary ventilation system.

  11. Impact of heating on passive and active biomechanics of suspended cells

    PubMed Central

    Chan, C. J.; Whyte, G.; Boyde, L.; Salbreux, G.; Guck, J.

    2014-01-01

    A cell is a complex material whose mechanical properties are essential for its normal functions. Heating can have a dramatic effect on these mechanical properties, similar to its impact on the dynamics of artificial polymer networks. We investigated such mechanical changes by the use of a microfluidic optical stretcher, which allowed us to probe cell mechanics when the cells were subjected to different heating conditions at different time scales. We find that HL60/S4 myeloid precursor cells become mechanically more compliant and fluid-like when subjected to either a sudden laser-induced temperature increase or prolonged exposure to higher ambient temperature. Above a critical temperature of 52 ± 1°C, we observed active cell contraction, which was strongly correlated with calcium influx through temperature-sensitive transient receptor potential vanilloid 2 (TRPV2) ion channels, followed by a subsequent expansion in cell volume. The change from passive to active cellular response can be effectively described by a mechanical model incorporating both active stress and viscoelastic components. Our work highlights the role of TRPV2 in regulating the thermomechanical response of cells. It also offers insights into how cortical tension and osmotic pressure govern cell mechanics and regulate cell-shape changes in response to heat and mechanical stress. PMID:24748957

  12. Impact of the amount of working fluid in loop heat pipe to remove waste heat from electronic component

    NASA Astrophysics Data System (ADS)

    Smitka, Martin; Kolková, Z.; Nemec, Patrik; Malcho, M.

    2014-03-01

    One of the options on how to remove waste heat from electronic components is using loop heat pipe. The loop heat pipe (LHP) is a two-phase device with high effective thermal conductivity that utilizes change phase to transport heat. It was invented in Russia in the early 1980's. The main parts of LHP are an evaporator, a condenser, a compensation chamber and a vapor and liquid lines. Only the evaporator and part of the compensation chamber are equipped with a wick structure. Inside loop heat pipe is working fluid. As a working fluid can be used distilled water, acetone, ammonia, methanol etc. Amount of filling is important for the operation and performance of LHP. This work deals with the design of loop heat pipe and impact of filling ratio of working fluid to remove waste heat from insulated gate bipolar transistor (IGBT).

  13. Passive amplification of the pyroelectric current in thin films on a heat-conducting substrate

    SciTech Connect

    Yablonskii, S. V.; Soto-Bustamante, E. A.

    2010-11-15

    We show both theoretically and experimentally that passive amplification of the pyroelectric current takes place when modulated radiation is recorded by a pyroelectric detector in some range of modulation frequencies. The amplification effect manifests itself in the fact that the current generated by a thin pyroelectric film lying on a massive heat-conducting substrate exceeds that in a freely suspended film. We use a ferroelectric 70:30 P(VDF-TrFE) copolymer, a crystalline guanidine pyroelectric, and a 70:30 composition of an achiral liquid-crystal polymer and its monomer PM6R14n-M6R14n to illustrate the frequency dependence of the pyroelectric current.

  14. Passive solar-heating retrofit of a maintenance facility: First-year performance

    NASA Astrophysics Data System (ADS)

    Jackson, D. R.; Callahan, J. M.

    1982-09-01

    A 12,000 sf maintenance facility in Connecticut was retrofitted with a 1,500 sf passive solar Trombe wall, 2 in. of foam roof insulation and a new control system that allows night/weekend temperature setback. A new separate boiler was installed to heat an office/locker wing of the facility. An energy-consumption monitoring system was installed and collected data for 11/2 years before the retrofit and one complete year after the retrofit. Actual energy consumption for the facility was very close to that predicted using simple analytic methods. After the solar wall was installed and other energy-conservation measures implemented the yearly oil consumption was reduced to 2744 gallons/year.

  15. Passive cooling safety system for liquid metal cooled nuclear reactors

    DOEpatents

    Hunsbedt, Anstein; Boardman, Charles E.; Hui, Marvin M.; Berglund, Robert C.

    1991-01-01

    A liquid metal cooled nuclear reactor having a passive cooling system for removing residual heat resulting from fuel decay during reactor shutdown. The passive cooling system comprises a plurality of partitions surrounding the reactor vessel in spaced apart relation forming intermediate areas for circulating heat transferring fluid which remove and carry away heat from the reactor vessel. The passive cooling system includes a closed primary fluid circuit through the partitions surrounding the reactor vessel and a partially adjoining secondary open fluid circuit for carrying transferred heat out into the atmosphere.

  16. Indirect passive cooling system for liquid metal cooled nuclear reactors

    DOEpatents

    Hunsbedt, Anstein; Boardman, Charles E.

    1990-01-01

    A liquid metal cooled nuclear reactor having a passive cooling system for removing residual heat resulting from fuel decay during reactor shutdown. The passive cooling system comprises a plurality of partitions surrounding the reactor vessel in spaced apart relation forming intermediate areas for circulating heat transferring fluid which remove and carry away heat from the reactor vessel. The passive cooling system includes a closed primary fluid circuit through the partitions surrounding the reactor vessel and a partially adjoining secondary open fluid circuit for carrying transferred heat out into the atmosphere.

  17. Precipitation and Latent Heating Distributions from Satellite Passive Microwave Radiometry. Part 1; Method and Uncertainties

    NASA Technical Reports Server (NTRS)

    Olson, William S.; Kummerow, Christian D.; Yang, Song; Petty, Grant W.; Tao, Wei-Kuo; Bell, Thomas L.; Braun, Scott A.; Wang, Yansen; Lang, Stephen E.; Johnson, Daniel E.

    2004-01-01

    A revised Bayesian algorithm for estimating surface rain rate, convective rain proportion, and latent heating/drying profiles from satellite-borne passive microwave radiometer observations over ocean backgrounds is described. The algorithm searches a large database of cloud-radiative model simulations to find cloud profiles that are radiatively consistent with a given set of microwave radiance measurements. The properties of these radiatively consistent profiles are then composited to obtain best estimates of the observed properties. The revised algorithm is supported by an expanded and more physically consistent database of cloud-radiative model simulations. The algorithm also features a better quantification of the convective and non-convective contributions to total rainfall, a new geographic database, and an improved representation of background radiances in rain-free regions. Bias and random error estimates are derived from applications of the algorithm to synthetic radiance data, based upon a subset of cloud resolving model simulations, and from the Bayesian formulation itself. Synthetic rain rate and latent heating estimates exhibit a trend of high (low) bias for low (high) retrieved values. The Bayesian estimates of random error are propagated to represent errors at coarser time and space resolutions, based upon applications of the algorithm to TRMM Microwave Imager (TMI) data. Errors in instantaneous rain rate estimates at 0.5 deg resolution range from approximately 50% at 1 mm/h to 20% at 14 mm/h. These errors represent about 70-90% of the mean random deviation between collocated passive microwave and spaceborne radar rain rate estimates. The cumulative algorithm error in TMI estimates at monthly, 2.5 deg resolution is relatively small (less than 6% at 5 mm/day) compared to the random error due to infrequent satellite temporal sampling (8-35% at the same rain rate).

  18. Thermal control system. [removing waste heat from industrial process spacecraft

    NASA Technical Reports Server (NTRS)

    Hewitt, D. R. (Inventor)

    1983-01-01

    The temperature of an exothermic process plant carried aboard an Earth orbiting spacecraft is regulated using a number of curved radiator panels accurately positioned in a circular arrangement to form an open receptacle. A module containing the process is insertable into the receptacle. Heat exchangers having broad exterior surfaces extending axially above the circumference of the module fit within arcuate spacings between adjacent radiator panels. Banks of variable conductance heat pipes partially embedded within and thermally coupled to the radiator panels extend across the spacings and are thermally coupled to broad exterior surfaces of the heat exchangers by flanges. Temperature sensors monitor the temperature of process fluid flowing from the module through the heat exchanges. Thermal conduction between the heat exchangers and the radiator panels is regulated by heating a control fluid within the heat pipes to vary the effective thermal length of the heat pipes in inverse proportion to changes in the temperature of the process fluid.

  19. Heat treatment in 110 °C liquid water used for passivating silicon surfaces

    NASA Astrophysics Data System (ADS)

    Nakamura, Tomohiko; Motoki, Takayuki; Ubukata, Junya; Sameshima, Toshiyuki; Hasumi, Masahiko; Mizuno, Tomohisa

    2016-04-01

    The simple passivation method of heat treatment in liquid water is discussed. Photo-induced effective minority carrier lifetime τ eff increased to 3.3 × 10-3 s above 110 °C for 1 h for 17-Ωcm n-type crystalline silicon. Increase in τ eff was observed ranging from 3.5 × 10-4 to 3.7 × 10-3 s for n-type silicon with resistivity ranging from 2 to 17 Ωcm. τ eff maintained high values ranging from 1.5 × 10-4 to 1.4 × 10-3 s for 1270 h. The metal-insulator-semiconductor-type diodes were formed on the top surfaces of the n-type and p-type substrates by forming Al and Au metals on the 0.7-nm-thin passivated layers. Rectified and Fowler-Nordheim current characteristics were observed in the dark field because of the difference of the work function between Al and Au. High photo-induced current density of 31.1 mA/cm2 and photovoltaic effect were observed in case of light illumination of AM 1.5 at 100 mW/cm2 to the rear surface. The recombination velocity in the regions under the metal electrode in the MIS structure was determined by lateral diffusion of photo-induced carriers. They were 1000 and 11,000 cm/s under Al and Au, respectively, in the n-type Si substrate.

  20. Methodology for characterizing heat removal mechanism in human skin during cryogen spray cooling.

    PubMed

    Pikkula, Brian M; Tunnell, James W; Anvari, Bahman

    2003-05-01

    Cryogen spray cooling (CSC) reduces epidermal damage during laser treatment of various dermatoses. The goal of this study was to determine the heat removal mechanism in skin and quantify the amount in response to CSC. Thermocouples were imbedded in four model substrates with a range of thermal diffusivities, greater than three orders of magnitude in difference, to measure the temperature profiles in response to CSC and sapphire contact cooling, which removes heat completely by conduction. An algorithm solving an inverse heat conduction problem was subsequently used to quantify the amount of heat removal from the substrates using the measured temperatures. The interface thermal conductance and internal temperatures within the substrates were computed by a finite difference algorithm that solved the heat conduction equation. Results verify a marked increase in heat removal and interface thermal conductance with increasing thermal diffusivity. By estimation from the model substrate results, heat removal and interface thermal conductance values for skin were obtained. Data demonstrate that during CSC, evaporation is the dominant heat transfer mechanism in materials with higher thermal diffusivities; however, conductive cooling dominates in substrates with lower thermal diffusivities such as skin. PMID:12757194

  1. Scalability of the natural convection shutdown heat removal test facility (NSTF) data to VHTR/NGNP RCCS designs.

    SciTech Connect

    Vilim, R .B.; Feldman, E. E.; Nuclear Engineering Division

    2007-08-07

    Passive safety in the Very High Temperature Reactor (VHTR) is strongly dependent on the thermal performance of the Reactor Cavity Cooling System (RCCS). Scaled experiments performed in the Natural Shutdown Test Facility (NSTF) are to provide data for assessing and/or improving computer code models for RCCS phenomena. Design studies and safety analyses that are to support licensing of the VHTR will rely on these models to achieve a high degree of certainty in predicted design heat removal rate. To guide in the selection and development of an appropriate set of experiments a scaling analysis has been performed for the air-cooled RCCS option. The goals were to (1) determine the phenomena that dominate the behavior of the RCCS, (2) determine the general conditions that must be met so that these phenomena and their relative importance are preserved in the experiments, (3) identify constraints specific to the NSTF that potentially might prevent exact similitude, and (4) then to indicate how the experiments can be scaled to prevent distortions in the phenomena of interest. The phenomena identified as important to RCCS operation were also the subject of a recent PIRT study. That work and the present work collectively indicate that the main phenomena influencing RCCS heat removal capability are (1) radiation heat transport from the vessel to the air ducts, (2) the integral effects of momentum and heat transfer in the air duct, (3) buoyancy at the wall inside the air duct giving rise to mixed convection, and (4) multidimensional effects inside the air duct caused by non-uniform circumferential heat flux and non-circular geometry.

  2. Method of high heat flux removal by usage of liquid spray cooling

    NASA Astrophysics Data System (ADS)

    Smakulski, Przemysław

    2013-09-01

    High heat flux removal are important issue in many perspective applications such as computer chips, laser diode arrays, or boilers working on supercritical parameters. Electronic microchips constructed nowadays are model example of high heat flux removal, where the cooling system have to maintain the temperature below 358 K and take heat flux up to 300 W/cm2. One of the most efficient methods of microchips cooling turns out to be the spray cooling method. Review of installations has been accomplished for removal at high heat flux with liquid sprays. In the article are shown high flux removal characteristic and dependences, boiling critical parameters, as also the numerical method of spray cooling analysis.

  3. Passive and Active Microwave Remote Sensing of Precipitation and Latent Heating Distributions in the Tropics from TRMM

    NASA Technical Reports Server (NTRS)

    Olson, William S.; Kummerow, Christian D.; Yang, Song; Haddad, Ziad S.; Tao, Wei-Kuo; Wang, Yansen; Lang, Stephen E.; Braun, Scott A.; Chiu, Christine; Wang, Jian-Jian

    2002-01-01

    Passive and active microwave remote sensing data are analyzed to identify signatures of precipitation and vertical motion in tropical convection. A database of cloud/radiative model simulations is used to quantify surface rain rates and latent heating profiles that are consistent with these signatures. At satellite footprint-scale (approximately 10 km), rain rate and latent heating estimates are subject to significant random errors, but by averaging the estimates in space and time, random errors are substantially reduced, Bias errors have been minimized by improving the microphysics in the supporting cloud/radiative model simulations, and by imposing a consistent definition of remotely-sensed and model-simulated convective/stratiform rain coverage. Remotely-sensed precipitation and latent heating distributions in the tropics are derived from Tropical Rainfall Measuring Mission (TRMM) and Special Sensor Microwave/ Imager (SSM/ I) sensor data. The prototype Version 6 TRMM passive microwave algorithm typically yields average heating profiles with maxima between 6 and 7 km altitude for organized mesoscale convective systems. Retrieved heating profiles for individual convective systems are compared to coincident estimates based upon a combination of dual-Doppler radar and rawinsonde data. Also, large-scale latent heating distributions are compared to estimates derived from a simpler technique that utilizes observations of surface rain rate and stratiform rain proportion to infer vertical heating structure. Results of these tests will be presented at the conference.

  4. Monitoring Organic Contaminant Fluxes Following Dam Removal Utilizing Passive Sampler Technology

    EPA Science Inventory

    Restoration of riverine habitats and their associated ecosystems is a growing priority for government agencies (e.g., USEPA, NOAA, USDA), as well as non-profit conservation organizations (e.g., American Rivers). Dam removal is a major component of many restoration projects credi...

  5. TRITIUM IN-BED ACCOUNTABILITY FOR A PASSIVELY COOLED, ELECTRICALLY HEATED HYDRIDE BED

    SciTech Connect

    Klein, J.; Foster, P.

    2011-01-21

    A PAssively Cooled, Electrically heated hydride (PACE) Bed has been deployed into tritium service in the Savannah River Site (SRS) Tritium Facilities. The bed design, absorption and desorption performance, and cold (non-radioactive) in-bed accountability (IBA) results have been reported previously. Six PACE Beds were fitted with instrumentation to perform the steady-state, flowing gas calorimetric inventory method. An IBA inventory calibration curve, flowing gas temperature rise ({Delta}T) versus simulated or actual tritium loading, was generated for each bed. Results for non-radioactive ('cold') tests using the internal electric heaters and tritium calibration results are presented. Changes in vacuum jacket pressure significantly impact measured IBA {Delta}T values. Higher jacket pressures produce lower IBA {Delta}T values which underestimate bed tritium inventories. The exhaust pressure of the IBA gas flow through the bed's U-tube has little influence on measured IBA {Delta}T values, but larger gas flows reduce the time to reach steady-state conditions and produce smaller tritium measurement uncertainties.

  6. Benchmark specifications for EBR-II shutdown heat removal tests

    SciTech Connect

    Sofu, T.; Briggs, L. L.

    2012-07-01

    Argonne National Laboratory (ANL) is hosting an IAEA-coordinated research project on benchmark analyses of sodium-cooled fast reactor passive safety tests performed at the Experimental Breeder Reactor-II (EBR-II). The benchmark project involves analysis of a protected and an unprotected loss of flow tests conducted during an extensive testing program within the framework of the U.S. Integral Fast Reactor program to demonstrate the inherently safety features of EBR-II as a pool-type, sodium-cooled fast reactor prototype. The project is intended to improve the participants' design and safety analysis capabilities for sodium-cooled fast reactors through validation and qualification of safety analysis codes and methods. This paper provides a description of the EBR-II tests included in the program, and outlines the benchmark specifications being prepared to support the IAEA-coordinated research project. (authors)

  7. Investigations on natural circulation in reactor models and shutdown heat removal systems for LMFBRs (liquid metal fast breeder reactors)

    SciTech Connect

    Hoffmann, H.; Weinberg, D.; Marten, K. ); Ieda, Yoshiaki )

    1989-11-01

    For sodium-cooled pool-type reactors, studies have been undertaken to remove the decay heat by natural convection alone, as in the case of failure of all power supplies. For this purpose, four immersion coolers (ICs), two each installed at a 180-deg circumferential position with respect to the others, are arranged within the reactor tank. They are connected with natural-drift air coolers through independent intermediate circuits. The primary sodium in the tank as well as the secondary sodium in the intermediate loop circulate by natural convection. The general functioning of this passive shutdown decay heat removal (DHR) system is demonstrated in 1:20 and 1:5 scale test models using water as a simulant fluid for sodium. The model design is based on the thermohydraulics similarity criteria. In the RAMONA three-dimensional 1:20 scale model, experiments were carried out to clarify the steady-state in-vessel thermohydraulics for different parameter combinations (core power, radial power distribution across the core, DHR by 2 or 4 ICs in operation, above-core structure geometry and position, different IC designs). For all mentioned parameters, temperatures and their fluctuations were measured and used to indicate isotherms and lines of identical temperature fluctuations. The flow patterns were observed visually. The experiments were recalculated by an updated version of the single-phase three-dimensional thermohydraulics code COMMIX.

  8. Cryogenic Heat-Exchanger Design for Freeze-out Removal of Carbon Dioxide from Landfill Gas

    NASA Astrophysics Data System (ADS)

    Chang, Ho-Myung; Chung, Myung Jin; Park, Seong Bum

    A cryogenic heat exchanger to remove carbon dioxide from landfill gas (LFG) is proposed and designed for applications to LNG production in distributed-scale. Since the major components of LFG are methane and carbon dioxide, CO2 removal is a significant pre-process in the liquefaction systems. A new and simple approach is proposed to directly remove carbon dioxide as frost on the surface wall along the cooling passage in a liquefying heat exchanger and to install two identical heat exchangers in parallel for alternative switching. As a first step of feasibility study, combined heat and mass transfer analysis is performed on the freeze-out process of CO2 in a counterflow heat exchanger, where CH4-CO2 mixture is cooled below its frost temperature in thermal contact with cold refrigerant. Engineering correlations for the analogy of heat and mass transfer are incorporated into numerical heat exchanger analysis with detailed fluid properties. The developed analytical model is used to estimate the distribution of CO2 accumulation and the required heat exchanger size with latent thermal load for the cryogenic CO2 removal in various operating conditions.

  9. Design Report for the ½ Scale Air-Cooled RCCS Tests in the Natural convection Shutdown heat removal Test Facility (NSTF)

    SciTech Connect

    Lisowski, D. D.; Farmer, M. T.; Lomperski, S.; Kilsdonk, D. J.; Bremer, N.; Aeschlimann, R. W.

    2014-06-01

    The Natural convection Shutdown heat removal Test Facility (NSTF) is a large scale thermal hydraulics test facility that has been built at Argonne National Laboratory (ANL). The facility was constructed in order to carry out highly instrumented experiments that can be used to validate the performance of passive safety systems for advanced reactor designs. The facility has principally been designed for testing of Reactor Cavity Cooling System (RCCS) concepts that rely on natural convection cooling for either air or water-based systems. Standing 25-m in height, the facility is able to supply up to 220 kW at 21 kW/m2 to accurately simulate the heat fluxes at the walls of a reactor pressure vessel. A suite of nearly 400 data acquisition channels, including a sophisticated fiber optic system for high density temperature measurements, guides test operations and provides data to support scaling analysis and modeling efforts. Measurements of system mass flow rate, air and surface temperatures, heat flux, humidity, and pressure differentials, among others; are part of this total generated data set. The following report provides an introduction to the top level-objectives of the program related to passively safe decay heat removal, a detailed description of the engineering specifications, design features, and dimensions of the test facility at Argonne. Specifications of the sensors and their placement on the test facility will be provided, along with a complete channel listing of the data acquisition system.

  10. Device for the removal of heat from waste water

    SciTech Connect

    Kalberer, F.

    1983-12-27

    Waste water is led into a container (1) through a inlet (4) at the top. A connection (20) between the inlet (4) and an outlet (21) having a check valve (22) comprises adjacent to the inlet (4) two inverted frusto-conical hollow bodies (24, 25) which are directly connected to each other. The connecting surface between the two hollow bodies (24, 25) is formed as a coarse screen (26). A round fine screen (30), which diverges downwardly, surrounds the hollow bodies (24,25). Heat exchangers (31) are located in the space between the fine screen (30) and the wall (2) of the container (1). An outlet (5) terminates at the bottom of the container and connects with a riser (6) and via a bend (7) with the sewerage conduit (8). Through the coarse screen (26) the waste water reaches the container, and the heat can reach the heat exchangers (31) through the fine screen (30), so that practically uncontaminated water is present at the heat exchangers, and the need for cleansing is substantially diminished.

  11. Heat removal characteristics of a primary containment vessel external spray

    SciTech Connect

    Kataoka, Yoshiyuki; Fujii, Tadashi; Murase, Michio

    1996-10-01

    To evaluate the heat release characteristics of a primary containment vessel (PCV) external spray (one of the PCV cooling systems utilizing the steel PCV wall as the heat transfer medium), the thermal-hydraulic characteristics of the falling liquid film on the PCV surface have been investigated experimentally. Then, the performance of the PCV external spray cooling system was evaluated using the experimental findings. The following results were obtained: (1) Heat transfer coefficients of the falling liquid film under steady-state conditions were increased as the film flow rate per unit length of the liquid film width increased, and they agreed with Wilke`s correlation within about {+-}15%. (2) The PCV surface temperature, when preheated up to 150 C, which is the supposed PCV temperature under a severe accident, decreased below 100 C within a few seconds when the PCV external spray was initiated, and boiling on the PCV surface could not be maintained. (3) Heat transfer coefficients of the falling liquid film under transient conditions were higher initially due to the boiling effect; however, they decreased rapidly and approached those under steady-state conditions. (4) The PCV external spray for the conceptually designed PCV could suppress the PCV pressure below the design goal under a severe accident.

  12. Nuclear energy plant with improved device for removing after-heat and emergency heat

    SciTech Connect

    Buscher, E.; Vinzens, K.

    1980-01-29

    The nuclear energy installation includes a nuclear reactor core, a primary circulatory loop connected to the reactor core and a circulating liquid metal medium therein heated by the reactor core. A first heat exchanger has a primary side connected in the primary circulatory loop, and a secondary side, a secondary circulatory loop connected to the secondary side of the first heat exchanger and a circulating liquid metal medium therein heated by heat transfer in the first heat exchanger from the liquid metal medium of the primary circulatory loop. A second heat exchanger has a primary side connected in the secondary circulatory loop, and a secondary side, a tertiary circulatory loop connected to the secondary side of the second heat exchanger and a circulating water/steam medium therein heated by heat transfer in the second heat exchanger from the liquid metal medium of the secondary circulatory loop. A condenser has a vapor/condensate side thereof connected in the tertiary circulatory loop, and a coolant side thereof connectible to a heat sink outside the installation. A third heat exchanger has a primary side connected to the primary side of the first heat exchanger, and a secondary side, a quaternary coolant loop connected to the secondary side of the third heat exchanger and connectible through the condenser to the heat sink.

  13. Aft Engine shop worker removes a heat shield on Columbia's main engines

    NASA Technical Reports Server (NTRS)

    2002-01-01

    KENNEDY SPACE CENTER, FLA. - Doug Buford, with the Aft Engine shop, works at removing a heat shield on Columbia, in the Orbiter Processing Facility. After small cracks were discovered on the LH2 Main Propulsion System (MPS) flow liners in two other orbiters, program managers decided to move forward with inspections on Columbia before clearing it for flight on STS-107. After removal of the heat shields, the three main engines will be removed. Inspections of the flow liners will follow. The July 19 launch of Columbia on STS-107 has been delayed a few weeks

  14. Aft Engine shop worker removes a heat shield on Columbia's main engines

    NASA Technical Reports Server (NTRS)

    2002-01-01

    KENNEDY SPACE CENTER, FLA. -- Doug Buford, with the Aft Engine shop, works at removing a heat shield on Columbia, in the Orbiter Processing Facility. After small cracks were discovered on the LH2 Main Propulsion System (MPS) flow liners in two other orbiters, program managers decided to move forward with inspections on Columbia before clearing it for flight on STS-107. After removal of the heat shields, the three main engines will be removed. Inspections of the flow liners will follow. The July 19 launch of Columbia on STS-107 has been delayed a few weeks

  15. Transient analysis of containment heat removal at Prairie Island with boiling in the fan coil tubes

    SciTech Connect

    Elicson, T.; Fraser, B.; Anderson, D.; Thomas, S.

    1996-12-31

    An analysis has been performed to determine the equilibrium cooling water flow rates and heat removal rates through the Prairie Island Nuclear Generating Plant containment fan coil units (CFCUs) under postulated accident conditions which leads to boiling in the CFCUs. Key components of the analysis include a detailed fan coil heat exchanger model, mass and energy conservation in the cooling tubes, two-phase flow effects on heat transfer and pressure drop, and pipe network modeling.

  16. Dose maintenance for Partial Liquid Ventilation: passive heat-and-moisture exchangers.

    PubMed

    Nugent, L J; Mazzoni, M C; Flaim, S F; Hoffman, J K; Sekins, K M

    1999-01-01

    Partial Liquid Ventilation (PLV), a promising method for the treatment of acute lung failure, has been evaluated in many animal studies. It has recently progressed to the point of controlled clinical trials in which patients of all ages on conventional mechanical ventilation (CMV) have their lungs substantially filled with a perfluorochemical (PFC) liquid, perflubron (PFB). During PLV, it is desirable to both maintain humidification and minimize the evaporation of PFB in order to maintain a desired dose in the lung and to reduce dose consumption and redosing effort. Heat-and-moisture exchangers (HMEs) have been used for years as a passive means of minimizing water vapor loss from the respiratory tract during CMV support of intensive care and surgical patients. In the current study, research was undertaken to leverage the operating principles of existing HMEs such that specialized "fluorophilic" HMEs (FHMEs), devices optimized for both water and PFB conservation, could be realized. A patient simulator (involving both water vapor and PFB vapor sources) was constructed and used in the in-vitro evaluation of various FHME concepts. Dose-retention efficiencies were determined with the aid of an infrared instrument and a digital thermohygrometer. Although no larger than commercial HMEs in terms of dead space (gas-occupying volume), efficient FHMEs resulted, offering less flow resistance (delta P) than their commercial counterparts. Additionally, the presence of PFB vapor did not appear to compromise the water-exchange efficiency of certain HME configurations. One promising FHME design was also tested in swine undergoing 12-hour PLV treatments. A mean conservation efficiency of 63% at an average tidal volume of 550 mL was shown, although somewhat lower efficiencies may result in adult patients because efficiency was found to trend downward with increasing tidal volume. The use of an FHME is expected to sustain dose levels in patients for longer periods with less frequent

  17. Effectiveness of laser-assisted irrigation and passive ultrasonic irrigation techniques on smear layer removal in middle and apical thirds.

    PubMed

    Ayranci, L B; Arslan, H; Akcay, M; Capar, I D; Gok, T; Saygili, G

    2016-01-01

    The purpose of this study was to investigate the evaluation of laser-assisted irrigation (LAI) on the removal of the smear layer as compared to passive ultrasonic irrigation (PUI). Forty-eight single-rooted, upper-central incisor teeth were selected and prepared with ProTaper rotary instruments up to size #40 (F4) at the working lengths. Specimens were divided into four groups, as follows: (a) PUI with 5 mL of 2.5% NaOCl for 60 s; (b) PUI with 2.5 mL of 17% EDTA and 2.5 mL of 2.5% NaOCl each for 30 s; (c) LAI with 5 mL of 2.5% NaOCl for 60 s; and (d) LAI with 2.5 mL of 17% EDTA and 2.5 mL of 2.5% NaOCl each for 30 s. In the PUI groups, the ultrasonically activated file was inserted 1 mm short of the working length, but in the LAI groups, the fiber tip was applied into the pulp chamber. LAI in the pulp chamber with the combination of 17% EDTA and 2.5% NaOCl removed more of the smear layer than the other groups (p < 0.018). LAI in the pulp chamber with the combination of 2.5% NaOCl and 17% EDTA better removed the smear layer than LAI applied similarly but without EDTA or PUI with the same NaOCl and EDTA combinations using an ultrasonically activated file inserted 1 mm short of the working length. PMID:26183211

  18. Passive heat therapy improves cutaneous microvascular function in sedentary humans via improved nitric oxide-dependent dilation.

    PubMed

    Brunt, Vienna E; Eymann, Taylor M; Francisco, Michael A; Howard, Matthew J; Minson, Christopher T

    2016-09-01

    Passive heat therapy (repeated hot tub or sauna use) reduces cardiovascular risk, but its effects on the mechanisms underlying improvements in microvascular function have yet to be studied. We investigated the effects of heat therapy on microvascular function and whether improvements were related to changes in nitric oxide (NO) bioavailability using cutaneous microdialysis. Eighteen young, sedentary, otherwise healthy subjects participated in 8 wk of heat therapy (hot water immersion to maintain rectal temperature ≥38.5°C for 60 min/session; n = 9) or thermoneutral water immersion (sham, n = 9), and participated in experiments before and after the 8-wk intervention in which forearm cutaneous hyperemia to 39°C local heating was assessed at three microdialysis sites receiving 1) Lactated Ringer's (Control), 2) N(ω)-nitro-l-arginine (l-NNA; nonspecific NO synthase inhibitor), and 3) 4-hydroxy-2,2,6,6-tetramethylpiperidine-1-oxyl (Tempol), a superoxide dismutase mimetic. The arm used for microdialysis experiments remained out of the water at all times. Data are means ± SE cutaneous vascular conductance (CVC = laser Doppler flux/mean arterial pressure), presented as percent maximal CVC (% CVCmax). Heat therapy increased local heating plateau from 42 ± 6 to 53 ± 6% CVCmax (P < 0.001) and increased NO-dependent dilation (difference in plateau between Control and l-NNA sites) from 26 ± 6 to 38 ± 4% CVCmax (P < 0.01), while no changes were observed in the sham group. When data were pooled across all subjects at 0 wk, Tempol had no effect on the local heating response (P = 0.53 vs. Control). There were no changes at the Tempol site across interventions (P = 0.58). Passive heat therapy improves cutaneous microvascular function by improving NO-dependent dilation, which may have clinical implications. PMID:27418688

  19. Jet pump-drive system for heat removal

    NASA Technical Reports Server (NTRS)

    French, James R. (Inventor)

    1987-01-01

    The invention does away with the necessity of moving parts such as a check valve in a nuclear reactor cooling system. Instead, a jet pump, in combination with a TEMP, is employed to assure safe cooling of a nuclear reactor after shutdown. A main flow exists for a reactor coolant. A point of withdrawal is provided for a secondary flow. A TEMP, responsive to the heat from said coolant in the secondary flow path, automatically pumps said withdrawn coolant to a higher pressure and thus higher velocity compared to the main flow. The high velocity coolant is applied as a driver flow for the jet pump which has a main flow chamber located in the main flow circulation pump. Upon nuclear shutdown and loss of power for the main reactor pumping system, the TEMP/jet pump combination continues to boost the coolant flow in the direction it is already circulating. During the decay time for the nuclear reactor, the jet pump keeps running until the coolant temperature drops to a lower and safe temperature where the heat is no longer a problem. At this lower temperature, the TEMP/jet pump combination ceases its circulation boosting operation. When the nuclear reactor is restarted and the coolant again exceeds the lower temperature setting, the TEMP/jet pump automatically resumes operation. The TEMP/jet pump combination is thus automatic, self-regulating and provides an emergency pumping system free of moving parts.

  20. Passive CO{sub 2} removal using a carbon fiber composite molecular sieve

    SciTech Connect

    Burchell, T.D.; Judkins, R.R.

    1995-12-01

    Manufacture and characterization of a carbon fiber composite molecular sieve (CFCMS), and its efficacy as a CO{sub 2} gas adsorbent are reported. The CFCMS consists of an isotropic pitch derived carbon fiber and a phenolic resin derived carbon binder. Activation (selective gasification) of the CFCMS creates microporosity in the carbon fibers, yielding high micropore volumes (>0.5 cm{sup 3}/g) and BET surface areas (>1000 m{sup 2}/g). Moreover, the CFCMS material is a rigid, strong, monolith with an open structure that allows the free-flow of fluids through the material. This combination of properties provides an adsorbent material that has several distinct advantages over granular adsorbents in gas separation systems such as pressure swing adsorption (PSA) units. The results of our initial evaluations of the CO{sub 2} adsorption capacity and kinetics of CFCMS are reported. The room temperature CO{sub 2} adsorption capacity of CFCMS is >120 mg of CO{sub 2} per g of CFCMS. A proposed project is described that targets the development, over a three-year period, of a demonstration separation system based on CFCMS for the removal of CO{sub 2} from a flue gas slip stream at a coal-fired power plant. The proposed program would be conducted jointly with industrial and utility partners.

  1. Effects of droplet velocity, diameter, and film height on heat removal during cryogen spray cooling.

    PubMed

    Pikkula, Brian M; Tunnell, James W; Chang, David W; Anvari, Bahman

    2004-08-01

    Cryogen spray cooling (CSC) is an effective method to reduce or eliminate epidermal damage during laser treatment of various dermatoses. This study sought to determine the effects of specific cryogen properties on heat removal. Heat removal was quantified using an algorithm that solved an inverse heat conduction problem from internal temperature measurements made within a skin phantom. A nondimensional parameter, the Weber number, characterized the combined effects of droplet velocity, diameter, and surface tension. CSC experiments with laser irradiation were conducted on ex vivo human skin samples to assess the effect of Weber number on epidermal protection. An empirical relationship between heat removal and the difference in droplet temperature and the substrate, droplet velocity, and diameter was obtained. Histological sections of irradiated ex vivo human skin demonstrated that sprays with higher Weber numbers increased epidermal protection. Results indicate that the cryogen film acts as an impediment to heat transfer between the impinging droplets and the substrate. This study offers the importance of Weber number in heat removal and epidermal protection. PMID:15446509

  2. Multiple pollutant removal using the condensing heat exchanger. Task 2, Pilot scale IFGT testing

    SciTech Connect

    Jankura, B.J.

    1996-01-01

    The purpose of Task 2 (IFGT Pilot-Scale Tests at the B&W Alliance Research Center) is to evaluate the emission reduction performance of the Integrated flue Gas Treatment (IFGT) process for coal-fired applications. The IFGT system is a two-stage condensing heat exchanger that captures multiple pollutants - while recovering waste heat. The IFGT technology offers the potential of a addressing the emission of SO{sub 2} and particulate from electric utilities currently regulated under the Phase I and Phase II requirements defined in Title IV, and many of the air pollutants that will soon be regulated under Title III of the Clean Air Act. The performance data will be obtained at pilot-scale conditions similar to full-scale operating systems. The task 2 IFGT tests have been designed to investigate several aspects of IFGT process conditions at a broader range of variable than would be feasible at a larger scale facility. The performance parameters that will be investigated are as follows: SO{sub 2} removal; particulate removal; removal of mercury and other heavy metals; NO{sub x} removal; HF and HCl removal; NH{sub 3} removal; ammonia-sulfur compounds generation; and steam injection for particle removal. For all of the pollutant removal tests, removal efficiency will be based on measurements at the inlet and outlet of the IFGT facility. Heat recovery measurements will also be made during these tests to demonstrate the heat recovery provided by the IFGT technology. This report provides the Final Test Plan for the first coal tested in the Task 2 pilot-scale IFGT tests.

  3. Analysis of heat generation using ultrasonic vibration for post removal.

    PubMed

    Dominici, John T; Clark, Stephen; Scheetz, James; Eleazer, Paul D

    2005-04-01

    This study measured the temperature of the root surface and post during the application of ultrasonic vibration to cemented posts to simulate post removal procedure. Root canal therapy was performed on ten extracted maxillary incisors. A stainless steel Parapost was cemented into each prepared post space. Ultrasonic vibration was applied to the post and temperatures were recorded at the coronal post and the cervical root surface. Data were analyzed with ANOVA using the independent variables of (a) time of ultrasonic application (15, 30, 45 and 60 s) and 2) location (post and root surface). Greater temperature increase was observed at the post (52.6 degrees C, SD 11.1; 82.6 degrees C, SD 20.1; 111.0 degrees C, SD 29.1; 125.3 degrees C, SD 33.2) compared to the root surface (9.5 degrees C, SD 4.6; 17.5 degrees C, SD 4.8; 25.4 degrees C, SD 7.3; 32.2 degrees C, SD 8.1) for each time period, P < 0.001. Ultrasonic application to the post for longer than 15 s generates high temperature on the root surface.

  4. Organic Fluids and Passive Cooling in a Supercritical Rankine Cycle for Power Generation from Low Grade Heat Sources

    NASA Astrophysics Data System (ADS)

    Vidhi, Rachana

    Low grade heat sources have a large amount of thermal energy content. Due to low temperature, the conventional power generation technologies result in lower efficiency and hence cannot be used. In order to efficiently generate power, alternate methods need to be used. In this study, a supercritical organic Rankine cycle was used for heat source temperatures varying from 125°C to 200°C. Organic refrigerants with zero ozone depletion potential and their mixtures were selected as working fluid for this study while the cooling water temperature was changed from 10-25°C. Operating pressure of the cycle has been optimized for each fluid at every heat source temperature to obtain the highest thermal efficiency. Energy and exergy efficiencies of the thermodynamic cycle have been obtained as a function of heat source temperature. Efficiency of a thermodynamic cycle depends significantly on the sink temperature. At areas where water cooling is not available and ambient air temperature is high, efficient power generation from low grade heat sources may be a challenge. Use of passive cooling systems coupled with the condenser was studied, so that lower sink temperatures could be obtained. Underground tunnels, buried at a depth of few meters, were used as earth-air-heat-exchanger (EAHE) through which hot ambient air was passed. It was observed that the air temperature could be lowered by 5-10°C in the EAHE. Vertical pipes were used to lower the temperature of water by 5°C by passing it underground. Nocturnal cooling of stored water has been studied that can be used to cool the working fluid in the thermodynamic cycle. It was observed that the water temperature can be lowered by 10-20°C during the night when it is allowed to cool. The amount of water lost was calculated and was found to be approximately 0.1% over 10 days. The different passive cooling systems were studied separately and their effects on the efficiency of the thermodynamic cycle were investigated. They were

  5. Jet pump-drive system for heat removal

    NASA Technical Reports Server (NTRS)

    French, J. R. (Inventor)

    1985-01-01

    A jet pump, in combination with a TEMP, is employed to assure safe cooling of a nuclear reactor after shutdown. A TEMP, responsive to the heat from the coolant in the secondary flow path, automatically pumps the withdrawn coolant to a higher pressure and thus higher velocity compared to the main flow. The high velocity coolant is applied as a driver flow for the jet pump which has a main flow chamber located in the main flow circulation pump. Upon nuclear shutdown and loss of power for the main reactor pumping system, the TEMP/jet pump combination continues to boost the coolant flow in the direction it is already circulating. During the decay time for the nuclear reactor, the jet pump keeps running until the coolant temperature drops to a lower and safe temperature. At this lower temperature, the TEMP/jet jump combination ceases its circulation boosting operation. The TEMP/jet pump combination is automatic, self-regulating and provides an emergency pumping system free of moving parts.

  6. Use of caustic magnesia to remove cadmium, nickel, and cobalt from water in passive treatment systems: column experiments

    SciTech Connect

    Tobias Stefan Roetting; Jordi Cama; Carlos Ayora; Jose-Luis Cortina; Joan De Pablo

    2006-10-15

    In the present study caustic magnesia obtained from calcination of magnesium carbonate was tested in column experiments as an alternative material for passive remediation systems to remove divalent metals. Caustic magnesia reacts with water to form magnesium hydroxide, which dissolves increasing the pH to values higher than 8.5. At these pH values, cadmium is precipitated as otavite and to a minor amount as a hydroxide. Cobalt and nickel are precipitated as hydroxides which form isostructural solids with brucite. Thus, metal concentrations as high as 75 mg/L in the inflowing water are depleted to values below 10 {mu}g/L. Magnesia dissolution is sufficiently fast to treat flows as high as 0.5 m{sup 3}/m{sup 2} per day. For reactive grain size of 2-4 mm, the column efficiency ends due to coating of the grains by precipitates, especially when iron and aluminum are present in the solution. 23 refs., 7 figs., 1 tab.

  7. Passive Fourier-transform infrared spectroscopy of chemical plumes: an algorithm for quantitative interpretation and real-time background removal

    NASA Astrophysics Data System (ADS)

    Polak, Mark L.; Hall, Jeffrey L.; Herr, Kenneth C.

    1995-08-01

    We present a ratioing algorithm for quantitative analysis of the passive Fourier-transform infrared spectrum of a chemical plume. We show that the transmission of a near-field plume is given by tau plume = (Lobsd - Lbb-plume)/(Lbkgd - Lbb-plume), where tau plume is the frequency-dependent transmission of the plume, L obsd is the spectral radiance of the scene that contains the plume, Lbkgd is the spectral radiance of the same scene without the plume, and Lbb-plume is the spectral radiance of a blackbody at the plume temperature. The algorithm simultaneously achieves background removal, elimination of the spectrometer internal signature, and quantification of the plume spectral transmission. It has applications to both real-time processing for plume visualization and quantitative measurements of plume column densities. The plume temperature (Lbb-plume ), which is not always precisely known, can have a profound effect on the quantitative interpretation of the algorithm and is discussed in detail. Finally, we provide an illustrative example of the use of the algorithm on a trichloroethylene and acetone plume.

  8. Method and apparatus for removing heat from electronic devices using synthetic jets

    SciTech Connect

    Sharma, Rajdeep; Weaver, Jr., Stanton Earl; Seeley, Charles Erklin; Arik, Mehmet; Icoz, Tunc; Wolfe, Jr., Charles Franklin; Utturkar, Yogen Vishwas

    2014-04-15

    An apparatus for removing heat comprises a heat sink having a cavity, and a synthetic jet stack comprising at least one synthetic jet mounted within the cavity. At least one rod and at least one engaging structure to provide a rigid positioning of the at least one synthetic jet with respect to the at least one rod. The synthetic jet comprises at least one orifice through which a fluid is ejected.

  9. Method and apparatus for removing heat from electronic devices using synthetic jets

    SciTech Connect

    Sharma, Rajdeep; Weaver, Stanton Earl; Seeley, Charles Erklin; Arik, Mehmet; Icoz, Tunc; Wolfe, Jr., Charles Franklin; Utturkar, Yogen Vishwas

    2015-11-24

    An apparatus for removing heat comprises a heat sink having a cavity, and a synthetic jet stack comprising at least one synthetic jet mounted within the cavity. At least one rod and at least one engaging structure to provide a rigid positioning of the at least one synthetic jet with respect to the at least one rod. The synthetic jet comprises at least one orifice through which a fluid is ejected.

  10. Multiple pollutant removal using the condensing heat exchanger. Task 3, Long term testing at the ECTC

    SciTech Connect

    Schulze, K.H.

    1996-01-01

    The objective of this task is to demonstrate long term operation of a condensing heat exchanger for coal-fired conditions. A small condensing heat exchanger will be installed at the Environmental Control Technology Center in Barker, New York. It will be installed downstream of the flue gas particulate removal system. The test will determine the amount of wear, if any, on the Teflon{trademark} covered internals of the heat exchanger. Visual inspection and measurements will be obtained for the Teflon{trademark} covered tubes during the test. The material wear study will conducted over a one year calendar period, and the CHX equipment will be operated to the fullest extent allowable.

  11. Modeling of heat transfer in a rotary kiln thermal desorder for removal of petroleum from soils

    SciTech Connect

    Chern, Hsien-Tsung; Krasnoperov, L.V.; Bozzelli, J.W.

    1996-10-01

    A continuous feed rotary kiln thermal desorber was designed and constructed to study the heat transfer in removal of petroleum hydrocarbons from contaminated soils. A mathematical model of heat transfer that correlates temperatures of gas, soil, and kiln wall will purge gas flow, soil feed rate, kiln rotation speed and soil residence time in the kiln desorber is developed. A fourth order Runge-Kutta method was used to numerically integrate the heat transfer process along the kiln length and to calculate the temperature profiles. Comparison of predicted and measured gas and soil temperature profile is presented.

  12. Influence of wick properties in a vertical LHP on remove waste heat from electronic equipment

    SciTech Connect

    Smitka, Martin E-mail: patrik.nemec@fstroj.uniza.sk Nemec, Patrik E-mail: patrik.nemec@fstroj.uniza.sk Malcho, Milan E-mail: patrik.nemec@fstroj.uniza.sk

    2014-08-06

    The loop heat pipe is a vapour-liquid phase-change device that transfers heat from evaporator to condenser. One of the most important parts of the LHP is the porous wick structure. The wick structure provides capillary force to circulate the working fluid. To achieve good thermal performance of LHP, capillary wicks with high permeability and porosity and fine pore radius are expected. The aim of this work is to develop porous wick of sintered nickel powder with different grain sizes. These porous wicks were used in LHP and there were performed a series of measurements to remove waste heat from the insulated gate bipolar transistor (IGBT)

  13. Influence of wick properties in a vertical LHP on remove waste heat from electronic equipment

    NASA Astrophysics Data System (ADS)

    Smitka, Martin; Nemec, Patrik; Malcho, Milan

    2014-08-01

    The loop heat pipe is a vapour-liquid phase-change device that transfers heat from evaporator to condenser. One of the most important parts of the LHP is the porous wick structure. The wick structure provides capillary force to circulate the working fluid. To achieve good thermal performance of LHP, capillary wicks with high permeability and porosity and fine pore radius are expected. The aim of this work is to develop porous wick of sintered nickel powder with different grain sizes. These porous wicks were used in LHP and there were performed a series of measurements to remove waste heat from the insulated gate bipolar transistor (IGBT).

  14. Heated stainless steel tube for ozone removal in the ambient air measurements of mono- and sesquiterpenes

    NASA Astrophysics Data System (ADS)

    Hellén, H.; Kuronen, P.; Hakola, H.

    2012-09-01

    Heated stainless steel inlets were optimized for the ozone removal and for the measurements of mono- and sesquiterpenes in ambient air. Five different inlets were used with different flows, temperatures and ozone and biogenic volatile organic compound (BVOC) concentrations. Both ozone removal capacities and recoveries of BVOCs were determined. Ozone and BVOCs were flushed through the inlet and recoveries were measured by an ozone monitor and adsorbent tube sampling of BVOCs with subsequent analysis with thermal desorption - gas chromatograph (GC) - mass spectrometer (MS). Recovery tests of BVOCs were conducted both with zero air and with ozone rich air. Inlets were optimized especially for online-GC and adsorbent tube measurements of mono- and sesquiterpenes. The results of this study show that it was possible to remove ozone without removing most VOCs with this set-up. Setting the temperature, stainless steel grade and flow correctly for different inlet lengths was found to have a crucial role. The results show that the ozone removal capacity increases with increasing temperature and inlet length. Stainless steel grade 316 was found to be more efficient than grade 304 with respect to ozone removal. Based only on the ozone removal capacity, the longest possible stainless steel inlet with heating would be the optimum solution. However, the recoveries of studied compounds had to be considered too. Of the tested set-ups, a 3 m inlet (¼ in. grade 304) heated to 120 °C with a flow of 1 or 2 l min-1 was found to give the best results with respect to the ozone removal efficiency and compound recovery. This inlet was removing ozone efficiently for at least 4 months when used for ambient air sampling at a rural forested site with a flow of 1 l min-1 (˜170 m3 of air flushed through the tube). A heated (140 °C) 1 m inlet (¼ in. grade 304 or ⅛ in. grade 316) was able to remove ozone with a constant flow of 0.8-1 l min-1 for about two weeks (˜18 m3 of air) and had

  15. Metabolic Heat Regenerated Temperature Swing Adsorption for CO(sub 2) and Heat Removal/Rejection in a Martian PLSS

    NASA Technical Reports Server (NTRS)

    Iacomini, Christine; Powers, Aaron; Bowers, Chad; Straub-Lopez, Katie; Anderson, Grant; MacCallum, Taber; Paul, Heather

    2007-01-01

    Two of the fundamental problems facing the development of a Portable Life Support System (PLSS) for use on Mars, are (i) heat rejection (because traditional technologies use sublimation of water, which wastes a scarce resource and contaminates the premises), and (ii) rejection of CO2 in an environment with a ppCO2 of 0.4-0.9 kPa. Patent-pending Metabolic heat regenerated Temperature Swing Adsorption (MTSA) technology is being developed to address both these challenges. The technology utilizes an adsorbent that when cooled with liquid CO2 to near sublimation temperatures (195K) removes metabolically-produced CO2 in the vent loop. Once fully loaded, the adsorbent is then warmed externally by the vent loop (approx. 300K), rejecting the captured CO2 to Mars ambient. Two beds are used to effect a continuous cycle of CO2 removal/rejection as well as facilitate heat exchange out of the vent loop. Any cryogenic fluid can be used in the application; however, since CO2 is readily available at Mars and can be easily produced and stored on the Martian surface, the solution is rather elegant and less complicated when employing liquid CO2. As some metabolic heat will need to be rejected anyway, finding a practical use for metabolic heat is also an overall benefit to the PLSS. To investigate the feasibility of the technology, a series of experiments was conducted which lead to the selection and partial characterization of an appropriate adsorbent. The adsorbent NaX successfully removed CO2 from a simulated vent loop at the prescribed temperature swing anticipated during PLSS operating conditions on Mars using a cryogenic fluid. Thermal conductivity of the adsorbent was also measured to eventually aid in a demonstrator design of the technology. These results provide no show stoppers to the development of MTSA technology and allow its development to focus on other design challenges as listed in the conclusions.

  16. Moisture removal characteristics of thin layer rough rice under sequenced infrared radiation heating and cooling

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Rice drying with infrared (IR) radiation has been investigated during recent years and showed promising potential with improved quality and energy efficiency. The objective of this study was to further investigate the moisture removal characteristics of thin layer rough rice heated by IR and cooled ...

  17. A&M. Radioactive parts security storage area, heat removal storage casks. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    A&M. Radioactive parts security storage area, heat removal storage casks. Plan, section, and details. Ralph M. Parsons 1480-7 ANP/GE-3-720-S-1. Date: November 1958. Approved by INEEL Classification Office for public release. INEEL index no. 034-0720-60-693-107459 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  18. Demonstration of Passive Fuel Cell Thermal Management Technology

    NASA Technical Reports Server (NTRS)

    Burke, Kenneth A.; Jakupca, Ian; Colozza, Anthony; Wynne, Robert; Miller, Michael; Meyer, Al; Smith, William

    2012-01-01

    The NASA Glenn Research Center is developing advanced passive thermal management technology to reduce the mass and improve the reliability of space fuel cell systems for the NASA Exploration program. The passive thermal management system relies on heat conduction within highly thermally conductive cooling plates to move the heat from the central portion of the cell stack out to the edges of the fuel cell stack. Using the passive approach eliminates the need for a coolant pump and other cooling loop components within the fuel cell system which reduces mass and improves overall system reliability. Previous development demonstrated the performance of suitable highly thermally conductive cooling plates and integrated heat exchanger technology to collect the heat from the cooling plates (Ref. 1). The next step in the development of this passive thermal approach was the demonstration of the control of the heat removal process and the demonstration of the passive thermal control technology in actual fuel cell stacks. Tests were run with a simulated fuel cell stack passive thermal management system outfitted with passive cooling plates, an integrated heat exchanger and two types of cooling flow control valves. The tests were run to demonstrate the controllability of the passive thermal control approach. Finally, successful demonstrations of passive thermal control technology were conducted with fuel cell stacks from two fuel cell stack vendors.

  19. Passive cooling system for liquid metal cooled nuclear reactors with backup coolant flow path

    DOEpatents

    Hunsbedt, Anstein; Boardman, Charles E.

    1993-01-01

    A liquid metal cooled nuclear fission reactor plant having a passive auxiliary safety cooling system for removing residual heat resulting from fuel decay during reactor shutdown, or heat produced during a mishap. This reactor plant is enhanced by a backup or secondary passive safety cooling system which augments the primary passive auxiliary cooling system when in operation, and replaces the primary system when rendered inoperable.

  20. Passive cooling system for top entry liquid metal cooled nuclear reactors

    DOEpatents

    Boardman, Charles E.; Hunsbedt, Anstein; Hui, Marvin M.

    1992-01-01

    A liquid metal cooled nuclear fission reactor plant having a top entry loop joined satellite assembly with a passive auxiliary safety cooling system for removing residual heat resulting from fuel decay during shutdown, or heat produced during a mishap. This satellite type reactor plant is enhanced by a backup or secondary passive safety cooling system which augments the primary passive auxiliary cooling system when in operation, and replaces the primary cooling system when rendered inoperative.

  1. Inorganic compounds for passive solar energy storage: Solid-state dehydration materials and high specific heat materials

    NASA Astrophysics Data System (ADS)

    Struble, L. J.; Brown, P. W.

    1986-04-01

    Two classes of hydrated inorganic salts have been studied to assess their potential as materials for passive solar energy storage. The materials are part of the quaternary system CaO-Al2O3-SO3-H2O and related chemical systems, and the two classes are typified by ettringite, a trisubstituted salt, and Friedel's salt, a monosubstituted salt. The trisubstituted salts were studied for their possible application in latent heat storage, utilizing a low-temperature dehydration reaction, and both classes were studies for their application in sensible heat storage. In order to assess their potential for energy storage, the salts have been synthesized, characterized by several analytical techniques, and thermal properties measured. The dehydration data of that the trisubstituted salts vary somewhat with chemical composition, with the temperature of the onset of dehydration ranging from 6(0)C to 33(0)C, and enthalpy changes on dehydration ranging from 60 to 200 cal/g. Heat capacity is less variable with composition; values for the trisubstituted phases are 30 cal/g/(0)C and for the monosubstituted phases between 0.23 and 0.28 cal/g/(0)C. Preliminary experiments indicate that the dehydration is reversible, and suggest that the materials might have additional potential as solar desiccant materials. These thermal data demonstrate the trisubstituted salts have potential as latent heat storage materials, and that both classes of salts have potential as sensible heat storage materials.

  2. Distinct Skeletal Muscle Gene Regulation from Active Contraction, Passive Vibration, and Whole Body Heat Stress in Humans

    PubMed Central

    Petrie, Michael A.; Kimball, Amy L.; McHenry, Colleen L.; Suneja, Manish; Yen, Chu-Ling; Sharma, Arpit; Shields, Richard K.

    2016-01-01

    Skeletal muscle exercise regulates several important metabolic genes in humans. We know little about the effects of environmental stress (heat) and mechanical stress (vibration) on skeletal muscle. Passive mechanical stress or systemic heat stress are often used in combination with many active exercise programs. We designed a method to deliver a vibration stress and systemic heat stress to compare the effects with active skeletal muscle contraction. Purpose: The purpose of this study is to examine whether active mechanical stress (muscle contraction), passive mechanical stress (vibration), or systemic whole body heat stress regulates key gene signatures associated with muscle metabolism, hypertrophy/atrophy, and inflammation/repair. Methods: Eleven subjects, six able-bodied and five with chronic spinal cord injury (SCI) participated in the study. The six able-bodied subjects sat in a heat stress chamber for 30 minutes. Five subjects with SCI received a single dose of limb-segment vibration or a dose of repetitive electrically induced muscle contractions. Three hours after the completion of each stress, we performed a muscle biopsy (vastus lateralis or soleus) to analyze mRNA gene expression. Results: We discovered repetitive active muscle contractions up regulated metabolic transcription factors NR4A3 (12.45 fold), PGC-1α (5.46 fold), and ABRA (5.98 fold); and repressed MSTN (0.56 fold). Heat stress repressed PGC-1α (0.74 fold change; p < 0.05); while vibration induced FOXK2 (2.36 fold change; p < 0.05). Vibration similarly caused a down regulation of MSTN (0.74 fold change; p < 0.05), but to a lesser extent than active muscle contraction. Vibration induced FOXK2 (p < 0.05) while heat stress repressed PGC-1α (0.74 fold) and ANKRD1 genes (0.51 fold; p < 0.05). Conclusion: These findings support a distinct gene regulation in response to heat stress, vibration, and muscle contractions. Understanding these responses may assist in developing regenerative

  3. Modes of mantle convection and the removal of heat from the earth's interior

    NASA Technical Reports Server (NTRS)

    Spohn, T.; Schubert, G.

    1982-01-01

    Thermal histories for two-layer and whole-mantle convection models are calculated and presented, based on a parameterization of convective heat transport. The model is composed of two concentric spherical shells surrounding a spherical core. The models were constrained to yield the observed present-day surface heat flow and mantle viscosity, in order to determine parameters. These parameters were varied to determine their effects on the results. Studies show that whole-mantle convection removes three times more primordial heat from the earth interior and six times more from the core than does two-layer convection (in 4.5 billion years). Mantle volumetric heat generation rates for both models are comparable to that of a potassium-depleted chondrite, and thus surface heat-flux balance does not require potassium in the core. Whole and two-layer mantle convection differences are primarily due to lower mantle thermal insulation and the lower heat removal efficiency of the upper mantle as compared with that of the whole mantle.

  4. GEOMETRY, HEAT REMOVAL AND KINETICS SCOPING MODELS FOR HYDROGEN STORAGE SYSTEMS

    SciTech Connect

    Hardy, B

    2007-11-16

    It is recognized that detailed models of proposed hydrogen storage systems are essential to gain insight into the complex processes occurring during the charging and discharging processes. Such insight is an invaluable asset for both assessing the viability of a particular system and/or for improving its design. The detailed models, however, require time to develop and run. Clearly, it is much more efficient to begin a modeling effort with a good system design and to progress from that point. To facilitate this approach, it is useful to have simplified models that can quickly estimate optimal loading and discharge kinetics, effective hydrogen capacities, system dimensions and heat removal requirements. Parameters obtained from these models can then be input to the detailed models to obtain an accurate assessment of system performance that includes more complete integration of the physical processes. This report describes three scoping models that assess preliminary system design prior to invoking a more detailed finite element analysis. The three models address the kinetics, the scaling and heat removal parameters of the system, respectively. The kinetics model is used to evaluate the effect of temperature and hydrogen pressure on the loading and discharge kinetics. As part of the kinetics calculations, the model also determines the mass of stored hydrogen per mass of hydride (in a particular reference form). As such, the model can determine the optimal loading and discharge rates for a particular hydride and the maximum achievable loading (over an infinite period of time). The kinetics model developed with the Mathcad{reg_sign} solver, runs in a mater of seconds and can quickly be used to identify the optimal temperature and pressure for either the loading or discharge processes. The geometry scoping model is used to calculate the size of the system, the optimal placement of heat transfer elements, and the gravimetric and volumetric capacities for a particular

  5. Multiple pollutant removal using the condensing heat exchanger: Phase 1 final report, October 1995--July 1997

    SciTech Connect

    Bailey, R.T.; Jankura, B.J.; Kudlac, G.A.

    1998-06-01

    The Integrated Flue Gas Treatment (IFGT) system is a new concept whereby a Teflon{reg_sign} covered condensing heat exchanger is adapted to remove certain flue gas constitutents, both particulate and gaseous, while recovering low level heat. Phase 1 includes two experimental tasks. One task dealt principally with the pollutant removal capabilities of the IFGT at a scale of about 1.2MW{sub t}. The other task studied the durability of the Teflon{reg_sign} covering to withstand the rigors of abrasive wear by fly ash emitted as a result of coal combustion. The pollutant removal characteristics of the IFGT system were measured over a wide range of operating conditions. The coals tested included high, medium and low-sulfur coals. The flue gas pollutants studied included ammonia, hydrogen chloride, hydrogen fluoride, particulate, sulfur dioxide, gas phase and particle phase mercury and gas phase and particle phase trace elements. The particulate removal efficiency and size distribution was investigated. These test results demonstrated that the IFGT system is an effective device for both acid gas absorption and fine particulate collection. The durability of the Teflon{reg_sign} covered heat exchanger tubes was studied on a pilot-scale single-stage condensing heat exchanger (CHX{reg_sign}). Data from the test indicate that virtually no decrease in Teflon{reg_sign} thickness was observed for the coating on the first two rows of heat exchanger tubes, even at high inlet particulate loadings. Evidence of wear was present only at the microscopic level, and even then was very minor in severity.

  6. Resistively-Heated Microlith-based Adsorber for Carbon Dioxide and Trace Contaminant Removal

    NASA Technical Reports Server (NTRS)

    Roychoudhury, S.; Walsh, D.; Perry, J.

    2005-01-01

    An integrated sorber-based Trace Contaminant Control System (TCCS) and Carbon Dioxide Removal Assembly (CDRA) prototype was designed, fabricated and tested. It corresponds to a 7-person load. Performance over several adsorption/regeneration cycles was examined. Vacuum regenerations at effective time/temperature conditions, and estimated power requirements were experimentally verified for the combined CO2/trace contaminant removal prototype. The current paper details the design and performance of this prototype during initial testing at CO2 and trace contaminant concentrations in the existing CDRA, downstream of the drier. Additional long-term performance characterization is planned at NASA. Potential system design options permitting associated weight, volume savings and logistic benefits, especially as relevant for long-duration space flight, are reviewed. The technology consisted of a sorption bed with sorbent- coated metal meshes, trademarked and patented as Microlith by Precision Combustion, Inc. (PCI). By contrast the current CO2 removal system on the International Space Station employs pellet beds. Preliminary bench scale performance data (without direct resistive heating) for simultaneous CO2 and trace contaminant removal was reviewed in SAE 2004-01-2442. In the prototype, the meshes were directly electrically heated for rapid response and accurate temperature control. This allowed regeneration via resistive heating with the potential for shorter regeneration times, reduced power requirement, and net energy savings vs. conventional systems. A novel flow arrangement, for removing both CO2 and trace contaminants within the same bed, was demonstrated. Thus, the need for a separate trace contaminant unit was eliminated resulting in an opportunity for significant weight savings. Unlike the current disposable charcoal bed, zeolites for trace contaminant removal are amenable to periodic regeneration.

  7. Natural circulation decay heat removal from an SP-100, 550 kWe power system for a lunar outpost

    NASA Technical Reports Server (NTRS)

    El-Genk, Mohamed S.; Xue, Huimin

    1992-01-01

    This research investigated the decay heat removal from the SP-100 reactor core of a 550-kWe power system for a lunar outpost by natural circulation of lithium coolant. A transient model that simulates the decay heat removal loop (DHRL) of the power system was developed and used to assess the system's decay heat removal capability. The effects of the surface area of the decay heat rejection radiator, the dimensions of the decay heat exchanger (DHE) flow duct, the elevation of the DHE, and the diameter of the rise and down pipes in the DHRL on the decay heat removal capability were examined. Also, to determine the applicability of test results at earth gravity to actual system performance on the lunar surface, the effect of the gravity constant (1 g and 1/6 g) on the thermal behavior of the system after shutdown was investigated.

  8. Cyclic process for producing methane from carbon monoxide with heat removal

    DOEpatents

    Frost, Albert C.; Yang, Chang-lee

    1982-01-01

    Carbon monoxide-containing gas streams are converted to methane by a cyclic, essentially two-step process in which said carbon monoxide is disproportionated to form carbon dioxide and active surface carbon deposited on the surface of a catalyst, and said carbon is reacted with steam to form product methane and by-product carbon dioxide. The exothermic heat of reaction generated in each step is effectively removed during each complete cycle so as to avoid a build up of heat from cycle-to-cycle, with particularly advantageous techniques being employed for fixed bed, tubular and fluidized bed reactor operations.

  9. Cyclic process for producing methane in a tubular reactor with effective heat removal

    DOEpatents

    Frost, Albert C.; Yang, Chang-Lee

    1986-01-01

    Carbon monoxide-containing gas streams are converted to methane by a cyclic, essentially two-step process in which said carbon monoxide is disproportionated to form carbon dioxide and active surface carbon deposited on the surface of a catalyst, and said carbon is reacted with steam to form product methane and by-product carbon dioxide. The exothermic heat of reaction generated in each step is effectively removed during each complete cycle so as to avoid a build up of heat from cycle-to-cycle, with particularly advantageous techniques being employed for fixed bed, tubular and fluidized bed reactor operations.

  10. Changes in arterial blood pressure elicited by severe passive heating at rest is associated with hyperthermia-induced hyperventilation in humans.

    PubMed

    Fujii, Naoto; Ichinose, Masashi; Honda, Yasushi; Tsuji, Bun; Watanabe, Kazuhito; Kondo, Narihiko; Nishiyasu, Takeshi

    2013-01-01

    The arterial blood pressure and ventilatory responses to severe passive heating at rest varies greatly among individuals. We tested the hypothesis that the increase in ventilation seen during severe passive heating of resting humans is associated with a decrease in arterial blood pressure. Passive heating was performed on 18 healthy males using hot water immersion to the level of the iliac crest and a water-perfused suit. We then divided the subjects into two groups: MAP(NOTINC) (n = 8), whose mean arterial blood pressure (MAP) at the end of heating had increased by ≤3 mmHg, and MAP(INC) (n = 10), whose MAP increased by >3 mmHg. Increases in esophageal temperature (T (es)) elicited by the heating were similar in the two groups (+2.3 ± 0.3 vs. +2.4 ± 0.4 °C). Early during heating (increase in T (es) was <1.5 °C), MAP, minute ventilation ([Formula: see text]), and end-tidal CO(2) pressure ([Formula: see text]) were similar between the groups. However, during the latter part of heating (increase in T (es) was ≥1.5 °C), the increase in [Formula: see text] and decrease in [Formula: see text] were significantly greater or tended to be greater, while the increase in MAP was significantly smaller in MAP(NOTINC) than MAP(INC). Among all subjects, heating-induced changes in [Formula: see text] significantly and negatively correlated with heating-induced changes in MAP during the latter part of heating (r = -0.52 to -0.74, P < 0.05). These results suggest that, in resting humans, 25-50 % of the variation in the magnitude of the arterial blood pressure response to severe passive heating can be explained by the magnitude of hyperthermia-induced hyperventilation.

  11. Origin of Surface-Driven Passive Liquid Flows.

    PubMed

    Yd, Sumith; Maroo, Shalabh C

    2016-08-30

    Passive liquid flow occurs in nature in the transport of water up tall trees and is desired for high-heat flux removal in thermal management devices. Typically, liquid-vapor surface tension is used to generate passive flows (e.g., capillary and Marangoni flows). In this work, we perform a fundamental molecular study on passive liquid flow driven by the solid-liquid surface tension force. Such surface tension values are first estimated by placing a liquid film over the surface and simulating various surface temperatures, followed by which simulations are performed by differential heating of the liquid film over the surface. Very strong passive liquid flows are obtained that lead to steady-state, continuous, and high-heat flux removal close to the maximum theoretical limit, as predicted by the kinetic theory of evaporation. Nondimensional empirical relations are developed for surface tension gradient, flow velocity, and evaporation rate. PMID:27483012

  12. Metabolic Heat Regenerated Temperature Swing Adsorption for CO2 and Heat Removal/Rejection in a Martian PLSS

    NASA Technical Reports Server (NTRS)

    Iacomini, Christine; Powers, Aaron; Bower, Chad; Straub-Lopez, Kathrine; Anderson, Grant; MacCallum, Taber; Paul, Heather L.

    2007-01-01

    Two of the fundamental problems facing the development of a Portable Life Support System (PLSS) for use on Mars, are (i) heat rejection (because traditional technologies use sublimation of water, which wastes a scarce resource and contaminates the premises), and (ii) rejection of carbon dioxide (CO2) in an environment with a CO2 partial pressure (ppCO2) of 0.4-0.9 kPa. Patent-pending Metabolic heat regenerated Temperature Swing Adsorption (MTSA) technology is being developed to address both these challenges. The technology utilizes an adsorbent that when cooled with liquid CO2 to near sublimation temperatures (195K) removes metabolically-produced CO2 in the ventilation loop. Once fully loaded, the adsorbent is then warmed externally by the ventilation loop (300K), rejecting the captured CO2 to Mars ambient. Two beds are used to provide a continuous cycle of CO2 removal/rejection as well as facilitate heat exchange out of the ventilation loop. Any cryogenic fluid can be used in the application; however, since CO2 is readily available on Mars and can be easily produced and stored on the Martian surface, the solution is rather elegant and less complicated when employing liquid CO2. As some metabolic heat will need to be rejected anyway, finding a practical use for metabolic heat is also an overall benefit to the PLSS. To investigate the feasibility of the technology, a series of experiments were conducted which lead to the selection and partial characterization of an appropriate adsorbent. The Molsiv Adsorbents 13X 8x12 (also known as NaX zeolite) successfully removed CO2 from a simulated ventilation loop at the prescribed temperature swing anticipated during PLSS operating conditions on Mars using a cryogenic fluid. Thermal conductivity of the adsorbent was also measured to eventually aid in a demonstrator design of the technology. These results provide no show stoppers to the development of MTSA technology and allow its development to focus on other design

  13. The effect of passive heating and head cooling on perception, cardiovascular function and cognitive performance in the heat.

    PubMed

    Simmons, Shona E; Saxby, Brian K; McGlone, Francis P; Jones, David A

    2008-09-01

    The present study examined the effects of raising both skin temperature and core temperature, separately and in combination, on perceptions of heat-related fatigue (alertness, contentment, calmness and thermal comfort), cardiovascular function and on objective measures of cognitive performance (reaction time and accuracy). Ten (six males) subjects had cognitive performance assessed in three conditions; at low skin and low core temperature (LL), at high skin and low core temperature (HL) and at high skin and high core temperatures (HH). In one trial, subjects had their head and neck cooled (HC); the other trial was a control (CON). Raising skin temperature increased heart rate and decreased perception of thermal comfort (P < 0.05), whereas raising both skin and core temperature decreased perception of heat-related fatigue (P < 0.05) and increased cardiovascular strain (P < 0.05) resulting in decrements in cognitive performance shown by faster reaction times (P < 0.05) and a loss of accuracy (P < 0.05). At high skin and core temperatures, cooling the head and neck improved feelings of heat-related fatigue (P < 0.05) and cardiovascular strain (P < 0.05), but had no effect on cognitive performance. In conclusion, the results of this study suggest that feelings of heat-related fatigue and cardiovascular strain can be attributed to a combination of elevated skin and core body temperature, whereas decrements in cognitive performance can be attributed to an elevated core temperature.

  14. Heat removal (wetting, heat transfer, T/H, secondary circuit, code validation etc.)

    SciTech Connect

    Dury, T.; Siman-Tov, M.

    1996-06-01

    This working group provided a comprehensive list of feasibility and uncertainty issues. Most of the issues seem to fall into the `needed but can be worked out` category. They feel these can be worked out as the project develops. A few issues can be considered critical or feasibility issues (that must be proven to be feasible). Those include: (1) Thermal shock and its mitigation (>1 MW); how to inject the He bubbles (if used) - back pressure into He lines - mercury traces in He lines; how to maintain proper bubble distribution and size (static and dynamic; if used); vibrations and fatigue (dynamic); possibility of cavitation from thermal shock. (2) Wetting and/or non-wetting of mercury on containment walls with or without gases and its effect on heat transfer (and materials). (3) Prediction capabilities in the CFD code; bubbles behavior in mercury (if used) - cross stream turbulence (ESS only) - wetting/non-wetting effects. (4) Cooling of beam `windows`; concentration of local heat deposition at center, especially if beam is of parabolic profile.

  15. Comparative study of chemical and physical methods for distinguishing between passive and metabolically active mechanisms of water contaminant removal by biofilms.

    PubMed

    Adapa, L M; Azimi, Y; Singh, S; Porcelli, D; Thompson, I P

    2016-09-15

    In this study, physical and chemical approaches were employed to distinguish between passive and active mechanisms in biofilms removing contaminants in waste waters and their relative merits were assessed. Respiration, post-exposure recovery and scanning electron microscopic analysis demonstrated that both ultraviolet (UV) treatment (300 mJ/cm(2)) and sodium azide (10 mM) completely inhibited metabolic activity at 5 and 24 h exposure, respectively, whilst not damaging the integrity of the biofilms. Amongst the commonly used chemical inhibitors, only sodium azide showed complete inhibition after 24 h incubation with only about 10% (±4%) of biofilm carbon released into the bulk solution, compared to 33-41% (±8%) when exposed to 5 mM and 10 mM 2,4-dinitrophenol (DNP) and 69-80% (±5%) when exposed to 2% and 5% w/v formalin, respectively. Biofilm inhibition with UV and sodium azide was found to be equally effective at inhibiting biofilms for treatment of triethanolamine (TEA) and benzotriazole (BTA): the results confirming that the dominant removal mechanism was biodegradation. However, the rates of glucose removal by sodium azide-inhibited biofilms were similar to controls, suggesting that chemical inhibitors were not effective for distinguishing the removal mechanisms of simple sugars. Statistically similar amounts of metal were removed by biofilms treated with UV and sodium azide in zinc, copper and cadmium single-systems: the results indicated that the removal mechanism is predominantly a passive biosorption process.

  16. Thermal performance of plate-fin heat exchanger using passive techniques: vortex-generator and nanofluid

    NASA Astrophysics Data System (ADS)

    Khoshvaght-Aliabadi, Morteza

    2016-04-01

    This experimental study investigates the effects of vortex-generator (VG) and Cu/water nanofluid flow on performance of plate-fin heat exchangers. The Cu/water nanofluids are produced by using a one-step method, namely electro-exploded wire technique, with four nanoparticles weight fractions (i.e. 0.1, 0.2, 0.3, and 0.4 %). Required properties of nanofluids are systematically measured, and empirical correlations are developed. A highly precise test loop is fabricated to obtain accurate results of the heat transfer and pressure drop characteristics. Experiments are conducted for nanofluids flow inside the plain and VG channels. Based on the experimental results, utilizing the VG channel instead of the plain channel enhances the heat transfer rate, remarkably. Also, the results show that the VG channel is more effective than the nanofluid on the performance of plate-fin heat exchangers. It is observed that the combination of the two heat transfer enhancement techniques has a noticeably high thermal-hydraulic performance, about 1.67. Finally, correlations are developed to predict Nusselt number and friction factor of nanofluids flow inside the VG channel.

  17. Reflex control of the cutaneous circulation during passive body core heating in humans.

    PubMed

    Peters, J K; Nishiyasu, T; Mack, G W

    2000-05-01

    The impact of body core heating on the interaction between the cutaneous and central circulation during blood pressure challenges was examined in eight adults. Subjects were exposed to -10 to -90 mmHg lower body negative pressure (LBNP) in thermoneutral conditions and -10 to -60 mmHg LBNP during heat stress. We measured forearm vascular conductance (FVC; ml. min(-1). 100 ml(-1). mmHg(-1)) by plethysmography; cutaneous vascular conductance (CVC) by laser-Doppler techniques; and central venous pressure, arterial blood pressure, and cardiac output by impedance cardiography. Heat stress increased FVC from 5.7 +/- 0.9 to 18.8 +/- 1.3 conductance units (CU) and CVC from 0.21 +/- 0.07 to 1.02 +/- 0.20 CU. The FVC-CVP relationship was linear over the entire range of LBNP and was shifted upward during heat stress with a slope increase from 0. 46 +/- 0.10 to 1.57 +/- 0.3 CU/mmHg CVP (P < 0.05). Resting CVP was lower during heat stress (6.3 +/- 0.6 vs. 7.7 +/- 0.6 mmHg; P < 0. 05) but fell to similar levels during LBNP as in normothermic conditions. Data analysis indicates an increased capacity, but not sensitivity, of peripheral baroreflex responses during heat stress. Laser-Doppler techniques detected thermoregulatory responses in the skin, but no significant change in CVC occurred during mild-to-moderate LBNP. Interestingly, very high levels of LBNP produced cutaneous vasodilation in some subjects.

  18. Passive solar heating and natural cooling of an earth-integrated design

    SciTech Connect

    Barnes, P. R.; Shapira, H. B.

    1980-01-01

    The Joint Institute for Heavy Ion Research is being designed with innovative features that will greatly reduce its energy consumption for heating, cooling, and lighting. A reference design has been studied and the effects of extending the overhang during summer and fall, varying glazing area, employing RIB, and reducing internal heat by natural lighting have been considered. The use of RIB and the extendable overhang increases the optimum window glazing area and the solar heating fraction. A mass-storage wall which will likely be included in the final design has also been considered. A figure of merit for commercial buildings is the total annual energy consumption per unit area of floor space. A highly efficient office building in the Oak Ridge area typically uses 120 to 160 kWhr/m/sup 2/. The Joint Institute reference design with natural lighting, an annual average heat pump coefficient of performance (COP) equal to 1.8, RIB, and the extendable overhang uses 71 kWhr/m/sup 2/. This figure was determined from NBSLD simulations corrected for the saving from RIB. The internal heat energy from lighting and equipment used in the simulation was 1653 kWhrs/month (high natural lighting case) which is much lower than conventional office buildings. This value was adopted because only a portion of the building will be used as office space and efforts will be made to keep internal heat generation low. The mass-storage wall and ambient air cooling will reduce energy consumption still further. The combined savings of the innovative features in the Joint Institute building are expected to result in a very energy efficient design. The building will be instrumented to monitor its performance and the measured data will provide a means of evaluating the energy-saving features. The efficiency of the design will be experimentally verified over the next several years.

  19. Control of reactor coolant flow path during reactor decay heat removal

    DOEpatents

    Hunsbedt, Anstein N.

    1988-01-01

    An improved reactor vessel auxiliary cooling system for a sodium cooled nuclear reactor is disclosed. The sodium cooled nuclear reactor is of the type having a reactor vessel liner separating the reactor hot pool on the upstream side of an intermediate heat exchanger and the reactor cold pool on the downstream side of the intermediate heat exchanger. The improvement includes a flow path across the reactor vessel liner flow gap which dissipates core heat across the reactor vessel and containment vessel responsive to a casualty including the loss of normal heat removal paths and associated shutdown of the main coolant liquid sodium pumps. In normal operation, the reactor vessel cold pool is inlet to the suction side of coolant liquid sodium pumps, these pumps being of the electromagnetic variety. The pumps discharge through the core into the reactor hot pool and then through an intermediate heat exchanger where the heat generated in the reactor core is discharged. Upon outlet from the heat exchanger, the sodium is returned to the reactor cold pool. The improvement includes placing a jet pump across the reactor vessel liner flow gap, pumping a small flow of liquid sodium from the lower pressure cold pool into the hot pool. The jet pump has a small high pressure driving stream diverted from the high pressure side of the reactor pumps. During normal operation, the jet pumps supplement the normal reactor pressure differential from the lower pressure cold pool to the hot pool. Upon the occurrence of a casualty involving loss of coolant pump pressure, and immediate cooling circuit is established by the back flow of sodium through the jet pumps from the reactor vessel hot pool to the reactor vessel cold pool. The cooling circuit includes flow into the reactor vessel liner flow gap immediate the reactor vessel wall and containment vessel where optimum and immediate discharge of residual reactor heat occurs.

  20. PKL experiments on loss of residual heat removal under shutdown conditions in PWRS

    SciTech Connect

    Umminger, Klaus; Schoen, Bernhard; Mull, Thomas

    2006-07-01

    When a pressurized water reactor (PWR) is shutdown for refueling, the main coolant inventory is reduced so that the level is at mid-loop elevation. Removal of the decay heat from the core is maintained by the residual heat removal system (RHRS), which under these conditions represents the only heat sink. Loss of RHRS under shutdown conditions has occurred several times worldwide and still plays an important role in risk studies for PWRs. The experimental investigation on loss of RHRS is one mayor topic in the current PKL test program which is included in an international project set up by the OECD. PKL is an integral test facility simulating a typical western-type 1300 MW PWR and is used to investigate the thermal-hydraulic system behavior of PWRs under accident situations. The PKL test facility is operated in the Technical Center of Framatome ANP in Erlangen, Germany. The tests on loss of RHRS have been performed with borated water and special measurement techniques for the determination of the boron concentration (online measurements). The PKL tests demonstrate that, as long as the primary circuit is closed, a failure of the residual heat removal system can be compensated by one or more steam generators, which remain filled with water on the secondary side and stay ready for use during refueling and other outages. However, the tests showed also that accumulations of large condensate inventories (with low boron concentration) can occur in the cold leg piping during mid-loop operation after loss of the RHRS. This paper summarizes the most important results of a PKL experiment dealing with loss of RHRS during mid-loop operation with closed primary circuit. Issues still open and needs for further investigations are also discussed. (authors)

  1. Multiple pollutant removal using the condensing heat exchanger: Phase 1 final report, November 1995--May 1997. Addendum 1: Task 2 topical report -- Pollutant removal tests

    SciTech Connect

    Bailey, R.T.; Jankura, B.J.

    1998-06-01

    Integrated Flue Gas Treatment (IFGT) uses two Condensing Heat Exchangers (CHXs{reg_sign}) in series to recover waste heat from the flue gas and remove a variety of pollutants from the flue gas. The Teflon{reg_sign}-covered internals of the condensing heat exchanger permit heat recovery at temperatures below the acid dew-point of the flue gas. The pollutant removal characteristics of the IFGT system were measured over a wide range of operating conditions in a pilot Integrated Flue Gas Treatment System rated at 1.2 MW{sub t} (4 million Btu/hr) using a wide range of coals. The coals tested included a high-sulfur coal, a medium-sulfur coal and a low-sulfur coal. The flue gas pollutants investigated included ammonia, hydrogen chloride, hydrogen fluoride, particulate, sulfur dioxide, gas phase and particle phase mercury and gas phase and particle phase trace elements. The particulate removal efficiency and size distribution was also investigated. Soda ash, lime and magnesium-lime scrubbing reagents were investigated. The test results show that the IFGT system can remove greater than 95% removal of acid gases with a liquid-to-gas ratio less than 1.34 l/m{sup 3} (10 gal/1,000 ft{sup 3}), and that lime reagents show promise as a substitute for soda ash. Particulate and ammonia gas removal was also very high. Ionic mercury removal averaged 80%, while elemental mercury removal was very low. Trace metals were found to be concentrated in the fine particulate with removal efficiencies in the range of 50% to 80%. The data measured in this task provides the basis for predictions of the performance of an IFGT system for both utility and industrial applications.

  2. A feasible way to remove the heat during adsorptive methane storage.

    PubMed

    Gütlein, Stefan; Burkard, Christoph; Zeilinger, Johannes; Niedermaier, Matthias; Klumpp, Michael; Kolb, Veronika; Jess, Andreas; Etzold, Bastian J M

    2015-01-01

    Methane originating from biogas or natural gas is an attractive and environmentally friendly alternative to gasoline. Adsorption is seen as promising storage technology, but the heat released limits fast filling of these systems. Here a lab scale adsorptive methane storage tank, capable to study the temperature increase during fast filling, was realized. A variation of the filling time from 1 h to 31 s, showed a decrease of the storage capacity of 14% and temperature increase of 39.6 °C. The experimental data could be described in good accordance with a finite element simulation solving the transient mass, energy, and impulse balance. The simulation was further used to extrapolate temperature development in real sized car tanks and for different heat pipe scenarios, resulting in temperature rises of approximately 110 °C. It could be clearly shown, that with heat conductivity as solei mechanism the heat cannot be removed in acceptable time. By adding an outlet to the tank a feed flow cooling with methane as heat carrier was realized. This setup was proofed in simulation and lab scale experiments to be a promising technique for fast adsorbent cooling and can be crucial to leverage the full potential of adsorptive methane gas storage. PMID:25485691

  3. A feasible way to remove the heat during adsorptive methane storage.

    PubMed

    Gütlein, Stefan; Burkard, Christoph; Zeilinger, Johannes; Niedermaier, Matthias; Klumpp, Michael; Kolb, Veronika; Jess, Andreas; Etzold, Bastian J M

    2015-01-01

    Methane originating from biogas or natural gas is an attractive and environmentally friendly alternative to gasoline. Adsorption is seen as promising storage technology, but the heat released limits fast filling of these systems. Here a lab scale adsorptive methane storage tank, capable to study the temperature increase during fast filling, was realized. A variation of the filling time from 1 h to 31 s, showed a decrease of the storage capacity of 14% and temperature increase of 39.6 °C. The experimental data could be described in good accordance with a finite element simulation solving the transient mass, energy, and impulse balance. The simulation was further used to extrapolate temperature development in real sized car tanks and for different heat pipe scenarios, resulting in temperature rises of approximately 110 °C. It could be clearly shown, that with heat conductivity as solei mechanism the heat cannot be removed in acceptable time. By adding an outlet to the tank a feed flow cooling with methane as heat carrier was realized. This setup was proofed in simulation and lab scale experiments to be a promising technique for fast adsorbent cooling and can be crucial to leverage the full potential of adsorptive methane gas storage.

  4. Effects of obesity and mild hypohydration on local sweating and cutaneous vascular responses during passive heat stress in females.

    PubMed

    Moyen, Nicole E; Burchfield, Jenna M; Butts, Cory L; Glenn, Jordan M; Tucker, Matthew A; Treece, Keeley; Smith, Amber J; McDermott, Brendon P; Ganio, Matthew S

    2016-08-01

    The purpose of this study was to evaluate the effect of obesity and mild hypohydration on local sweating (LSR) and cutaneous vascular conductance (CVC) responses during passive heat stress in females. Thirteen obese (age, 24 ± 4 years; 45.4% ± 5.2% body fat) and 12 nonobese (age, 22 ± 2 years; 25.1% ± 3.9% body fat) females were passively heated (1.0 °C rectal temperature increase) while either euhydrated (EUHY) or mildly hypohydrated (HYPO; via fluid restriction). Chest and forearm LSR (ventilated capsule) and CVC (Laser Doppler flowmetry) onset, sensitivity, and plateau/steady state were recorded as mean body temperature increased (ΔTb). Participants began trials EUHY (urine specific gravity, Usg = 1.009 ± 0.006) or HYPO (Usg = 1.025 ± 0.004; p < 0.05), and remained EUHY or HYPO. Independent of obesity, HYPO decreased sweat sensitivity at the chest (HYPO = 0.79 ± 0.35, EUHY = 0.95 ± 0.39 Δmg·min(-1)·cm(-2)/°C ΔTb) and forearm (HYPO = 0.82 ± 0.39, EUHY = 1.06 ± 0.34 Δmg·min(-1)·cm(-2)/°C ΔTb); forearm LSR plateau was also decreased (HYPO = 0.66 ± 0.19, EUHY = 0.78 ± 0.23 mg·min(-1)·cm(-2); all p < 0.05). Overall, obese females had lower chest-sweat sensitivity (0.72 ± 0.35 vs. 1.01 ± 0.33 Δmg·min(-1)·cm(-2)/°C ΔTb) and plateau (0.55 ± 0.27 vs. 0.80 ± 0.25 mg·min(-1)·cm(-2); p < 0.05). While hypohydrated, obese females had a lower chest LSR (p < 0.05) versus nonobese females midway (0.45 ± 0.26 vs. 0.73 ± 0.23 mg·min(-1)·cm(-2)) and at the end (0.53 ± 0.27 vs. 0.81 ± 0.24 mg·min(-1)·cm(-2)) of heating. Furthermore, HYPO (relative to the EUHY trials) led to a greater decrease in CVC sensitivity in obese (-28 ± 27 Δ% maximal CVC/°C ΔTb) versus nonobese females (+9.2 ± 33 Δ% maximal CVC/°C ΔTb; p < 0.05). In conclusion, mild hypohydration impairs females' sweating responses during passive heat stress, and this effect is exacerbated when obese. PMID:27455036

  5. Removal of histological sections from glass for electron microscopy - Use of Quetol 651 resin and heat

    NASA Technical Reports Server (NTRS)

    Kraft, L. M.; Joyce, K.; Dantoni Damelio, E.

    1983-01-01

    A number of approaches have been used to separate stained conventional histological sections from glass slides in preparation for a study with the electron microscope. However, in each reported case some problems were encountered with respect to the separation process. The present investigation is concerned with the use of the epoxy resin Quetol 651 as an embedding medium for this procedure, taking into account the simple application of heat (62-64 C) for performing the separation step. After the tissue has been removed from the glass by the considered technique, it is thin sectioned, and stained with uranyl acetate-lead citrate.

  6. EFFECT OF SHORT-TERM HEAT ACCLIMATION TRAINING ON KINETICS OF LACTATE REMOVAL FOLLOWING MAXIMAL EXERCISE

    PubMed Central

    DiLeo, T.D.; Powell, J.B.; Kang, H-K.; Roberge, R.J.; Coca, A.; Kim, J-H.

    2016-01-01

    AIM Heat acclimation (HA) evokes numerous physiological adaptations, improves heat tolerance and has also been shown to enhance lactate (LA) responses during exercise, similar to that seen with endurance training. The purpose of this study was to examine whether HA improves the body’s ability to remove LA during recovery following maximal exercise. METHODS Ten healthy men completed two trials of maximal treadmill exercise (PRE- and POST-HA) separated by 5 days of HA. Each day of HA consisted of two 45 minute periods of cycling at ~50% VO2max separated by a 15min rest period in an environmental chamber (Tdb 45°C, RH 20%). In PRE-/POST-HA trials, venous blood was collected during 60 minutes of recovery to determine LA concentrations and removal kinetics (A2: amplitude and y2: velocity constant) using bi-exponential curve fitting. RESULTS Physiological adaptation to heat was significantly developed during HA, as evidenced by end-exercise Tre (DAY 1 vs. 5) (38.89±0.56 vs. 38.66±0.44 °C), Tsk (38.07±.51 vs. 37.66±.48 °C), HR (175.0±9.9 vs. 165.0±18.5 beats·min−1), and sweat rate (1.24 ±.26 vs. 1.47 ±.27 L·min−1) (p<.05). However, there was no significant difference in either LA concentrations (LA0min: 8.78±1.08 vs. 8.69±1.23; LApeak: 10.97±1.77 vs. 10.95±1.46; and La60min; 2.88±.82 vs. 2.96±.93 mmol·L−1) or removal kinetics (A2: −13.05±7.05 vs −15.59±7.90 mmol.L−1 and y2: .02±.01 vs .03±.01 min−1). CONCLUSION The present study concluded that, while effective in inducing thermo-physiological adaptations to heat stress, short-term HA does not improve the body’s ability to remove LA following maximal exercise. Therefore, athletes and workers seeking faster LA recovery from intense physical activity may not benefit from short-term HA. PMID:25286892

  7. Cooling system for removing metabolic heat from an hermetically sealed spacesuit

    NASA Technical Reports Server (NTRS)

    Webbon, B. W.; Vykukal, H. C.; Williams, B. A. (Inventor)

    1978-01-01

    An improved cooling and ventilating system is described for removing metabolic heat, waste gases and water vapor generated by a wearer of an hermetically sealed spacesuit. The cooling system was characterized by a body suit, having a first circuit for simultaneously establishing a cooling flow of water through the thorax and head sections of the body suit. Circulation patches were included mounted in the thorax section and head section of the body suit. A second circuit for discharing a flow of gas throughout the spacesuit and a disconnect unit for coupling the circuits with a life support system externally related to the spacesuit were provided.

  8. Parametric Study to Characterize Low Activity Waste Tank Heat Removal Alternatives for Phase 1 Specification Development

    SciTech Connect

    GRENARD, C.E.

    2000-09-11

    Alternative for removing heat from Phase 1, low-activity waste feed double-shell tanks using the ventilation systems have been analyzed for Phase 1 waste feed delivery. The analysis was a parametric study using a model that predicted the waste temperatures for a range of primary and annulus ventilation system flow rates. The analysis was performed to determine the ventilation flow required to prevent the waste temperature from exceeding the Limiting Conditions for Operation limits during normal operation and the Safety Limits during off-normal events.

  9. Performance predictions for passive solar water heating systems. Report 1: Performance monitoring to validate site-specific estimates of passive solar water heaters. Report 2: Laboratory report. Passive solar water heater tests

    NASA Astrophysics Data System (ADS)

    Robinson, David; Martin, Ken

    1988-05-01

    The two reports included in this publication describe work done to validate performance prediction procedures and test methods for passive solar domestic hot water systems. The reports assess established prediction procedures and investigate the validity of testing techniques. The intent is to develop methodologies for passive solar systems at a level similar to that already in place for active solar systems.

  10. Precipitation and Latent Heating Distributions from Satellite Passive Microwave Radiometry. Part II: Evaluation of Estimates Using Independent Data

    NASA Astrophysics Data System (ADS)

    Yang, Song; Olson, William S.; Wang, Jian-Jian; Bell, Thomas L.; Smith, Eric A.; Kummerow, Christian D.

    2006-05-01

    Rainfall rate estimates from spaceborne microwave radiometers are generally accepted as reliable by a majority of the atmospheric science community. One of the Tropical Rainfall Measuring Mission (TRMM) facility rain-rate algorithms is based upon passive microwave observations from the TRMM Microwave Imager (TMI). In Part I of this series, improvements of the TMI algorithm that are required to introduce latent heating as an additional algorithm product are described. Here, estimates of surface rain rate, convective proportion, and latent heating are evaluated using independent ground-based estimates and satellite products. Instantaneous, 0.5°-resolution estimates of surface rain rate over ocean from the improved TMI algorithm are well correlated with independent radar estimates (r ˜0.88 over the Tropics), but bias reduction is the most significant improvement over earlier algorithms. The bias reduction is attributed to the greater breadth of cloud-resolving model simulations that support the improved algorithm and the more consistent and specific convective/stratiform rain separation method utilized. The bias of monthly 2.5°-resolution estimates is similarly reduced, with comparable correlations to radar estimates. Although the amount of independent latent heating data is limited, TMI-estimated latent heating profiles compare favorably with instantaneous estimates based upon dual-Doppler radar observations, and time series of surface rain-rate and heating profiles are generally consistent with those derived from rawinsonde analyses. Still, some biases in profile shape are evident, and these may be resolved with (a) additional contextual information brought to the estimation problem and/or (b) physically consistent and representative databases supporting the algorithm. A model of the random error in instantaneous 0.5°-resolution rain-rate estimates appears to be consistent with the levels of error determined from TMI comparisons with collocated radar. Error

  11. Precipitation and Latent Heating Distributions from Satellite Passive Microwave Radiometry. Part 2; Evaluation of Estimates Using Independent Data

    NASA Technical Reports Server (NTRS)

    Yang, Song; Olson, William S.; Wang, Jian-Jian; Bell, Thomas L.; Smith, Eric A.; Kummerow, Christian D.

    2004-01-01

    Rainfall rate estimates from space-borne k&ents are generally accepted as reliable by a majority of the atmospheric science commu&y. One-of the Tropical Rainfall Measuring Mission (TRh4M) facility rain rate algorithms is based upon passive microwave observations fiom the TRMM Microwave Imager (TMI). Part I of this study describes improvements in the TMI algorithm that are required to introduce cloud latent heating and drying as additional algorithm products. Here, estimates of surface rain rate, convective proportion, and latent heating are evaluated using independent ground-based estimates and satellite products. Instantaneous, OP5resolution estimates of surface rain rate over ocean fiom the improved TMI algorithm are well correlated with independent radar estimates (r approx. 0.88 over the Tropics), but bias reduction is the most significant improvement over forerunning algorithms. The bias reduction is attributed to the greater breadth of cloud-resolving model simulations that support the improved algorithm, and the more consistent and specific convective/stratiform rain separation method utilized. The bias of monthly, 2.5 deg. -resolution estimates is similarly reduced, with comparable correlations to radar estimates. Although the amount of independent latent heating data are limited, TMI estimated latent heating profiles compare favorably with instantaneous estimates based upon dual-Doppler radar observations, and time series of surface rain rate and heating profiles are generally consistent with those derived from rawinsonde analyses. Still, some biases in profile shape are evident, and these may be resolved with: (a) additional contextual information brought to the estimation problem, and/or; (b) physically-consistent and representative databases supporting the algorithm. A model of the random error in instantaneous, 0.5 deg-resolution rain rate estimates appears to be consistent with the levels of error determined from TMI comparisons to collocated radar

  12. Removal of ammonium-nitrogen from groundwater using a fully passive permeable reactive barrier with oxygen-releasing compound and clinoptilolite.

    PubMed

    Huang, Guoxin; Liu, Fei; Yang, Yingzhao; Deng, Wei; Li, Shengpin; Huang, Yuanying; Kong, Xiangke

    2015-05-01

    A novel fully passive permeable reactive barrier (PRB) with oxygen-releasing compound (ORC) and clinoptilolite was proposed for the removal of ammonium-nitrogen from groundwater. The PRB involves a combination of oxygen release, biological nitrification, ion exchange, and bioregeneration. A pilot-scale performance comparison experiment was carried out employing three parallel columns to assess the proposed PRB. The results showed that the PRB achieved nearly complete [Formula: see text] depletion (>99%). [Formula: see text] of 5.23-10.88 mg/L was removed, and [Formula: see text] of <1.93 mg/L and [Formula: see text] of 2.03-19.67 mg/L were generated. Ion exchange and biological nitrification both contributed to [Formula: see text] removal, and the latter played a dominant role under the condition of sufficient oxygen. Biological nitrification favored a delay in sorption saturation and a release of exchange sites. The ORC could sufficiently, efficiently supply oxygen for approximately 120 pore volumes. The clinoptilolite ensured a robust [Formula: see text] removal in case of temporary insufficient biological activities. No external alkalinity sources had to be supplied and no inhibition of aerobic metabolism occurred. The ceramicite had a negligible effect on the biomass growth. Based on the research findings, a full-scale continuous wall PRB was installed in Shenyang, China in 2012.

  13. Passivation of nitinol wire for vascular implants--a demonstration of the benefits.

    PubMed

    O'Brien, B; Carroll, W M; Kelly, M J

    2002-04-01

    This study investigated a passivation process for polished nitinol wires and vascular stent components, after being given a typical shape setting heat treatment. Heat treated samples were passivated in a nitric acid solution and a series of corrosion tests, surface analysis and chemical analysis was performed. Potentiodynamic polarization tests demonstrated a significant increase in breakdown potential for passivated samples, compared to heat treated surfaces. Surface analysis indicated that the passivation reduces Ni and NiO content in the oxide and increases TiO2 content. Chemical analysis of passivation solutions suggests that the improvement in corrosion resistance is proportional to the quantity of nickel removed. Long term immersion tests demonstrate that nickel release from the surface of the material decreases with time and the quantity of nickel released is lower for passivated samples. The improved corrosion resistance is maintained after extended periods of immersion in saline solution.

  14. Ultrafine particle removal by residential heating, ventilating, and air-conditioning filters.

    PubMed

    Stephens, B; Siegel, J A

    2013-12-01

    This work uses an in situ filter test method to measure the size-resolved removal efficiency of indoor-generated ultrafine particles (approximately 7-100 nm) for six new commercially available filters installed in a recirculating heating, ventilating, and air-conditioning (HVAC) system in an unoccupied test house. The fibrous HVAC filters were previously rated by the manufacturers according to ASHRAE Standard 52.2 and ranged from shallow (2.5 cm) fiberglass panel filters (MERV 4) to deep-bed (12.7 cm) electrostatically charged synthetic media filters (MERV 16). Measured removal efficiency ranged from 0 to 10% for most ultrafine particles (UFP) sizes with the lowest rated filters (MERV 4 and 6) to 60-80% for most UFP sizes with the highest rated filter (MERV 16). The deeper bed filters generally achieved higher removal efficiencies than the panel filters, while maintaining a low pressure drop and higher airflow rate in the operating HVAC system. Assuming constant efficiency, a modeling effort using these measured values for new filters and other inputs from real buildings shows that MERV 13-16 filters could reduce the indoor proportion of outdoor UFPs (in the absence of indoor sources) by as much as a factor of 2-3 in a typical single-family residence relative to the lowest efficiency filters, depending in part on particle size. PMID:23590456

  15. Ultrafine particle removal by residential heating, ventilating, and air-conditioning filters.

    PubMed

    Stephens, B; Siegel, J A

    2013-12-01

    This work uses an in situ filter test method to measure the size-resolved removal efficiency of indoor-generated ultrafine particles (approximately 7-100 nm) for six new commercially available filters installed in a recirculating heating, ventilating, and air-conditioning (HVAC) system in an unoccupied test house. The fibrous HVAC filters were previously rated by the manufacturers according to ASHRAE Standard 52.2 and ranged from shallow (2.5 cm) fiberglass panel filters (MERV 4) to deep-bed (12.7 cm) electrostatically charged synthetic media filters (MERV 16). Measured removal efficiency ranged from 0 to 10% for most ultrafine particles (UFP) sizes with the lowest rated filters (MERV 4 and 6) to 60-80% for most UFP sizes with the highest rated filter (MERV 16). The deeper bed filters generally achieved higher removal efficiencies than the panel filters, while maintaining a low pressure drop and higher airflow rate in the operating HVAC system. Assuming constant efficiency, a modeling effort using these measured values for new filters and other inputs from real buildings shows that MERV 13-16 filters could reduce the indoor proportion of outdoor UFPs (in the absence of indoor sources) by as much as a factor of 2-3 in a typical single-family residence relative to the lowest efficiency filters, depending in part on particle size.

  16. Los Alamos PWR decay-heat-removal studies. Summary results and conclusions

    SciTech Connect

    Boyack, B E; Henninger, R J; Horley, E; Lime, J F; Nassersharif, B; Smith, R

    1986-03-01

    The adequacy of shutdown-decay-heat removal in pressurized water reactors (PWRs) is currently under investigation by the Nuclear Regulatory Commission. One part of this effort is the review of feed-and-bleed procedures that could be used if the normal cooling mode through the steam generators were unavailable. Feed-and-bleed cooling is effected by manually activating the high-pressure injection (HPI) system and opening the power-operated relief valves (PORVs) to release the core decay energy. The feasibility of the feed-and-bleed concept as a diverse mode of heat removal has been evaluated at the Los Alamos National Laboratory. The TRAC-PF1 code has been used to predict the expected performance of the Oconee-1 and Calvert Cliffs-1 reactors of Bobcock and Wilcox and Combustion Engineering, respectively, and the Zion-1 and H.B. Robinson-2 plants of Westinghouse. Feed and bleed was successfully applied in each of the four plants studied, provided it was initiated no later than the time of loss of secondary heat sink. Feed and bleed was successfully applied in two of the plants, Oconee-1 and Zion-1, provided it was initiated no later than the time of primary system saturation. Feed and bleed in Calvert Cliffs-1 when initiated at the time of primary system saturation did result in core dryout; however, the core heatup was eventually terminated by coolant injection. Feed-and-bleed initiation at primary system saturation was not studied for H.B. Robinson-2. Insights developed during the analyses of specific plant transients have been identified and documented. 33 refs., 107 figs., 26 tabs.

  17. Mitigation Measures Following a Loss-of-Residual-Heat-Removal Event During Shutdown

    SciTech Connect

    Seul, Kwang Won; Bang, Young Seok; Kim, Hho Jung

    2000-10-15

    The transient following a loss-of-residual-heat-removal event during shutdown was analyzed to determine the containment closure time (CCT) to prevent uncontrolled release of fission products and the gravity-injection path and rate (GIPR) for effective core cooling using the RELAP5/MOD3.2 code. The plant conditions of Yonggwang Units 3 and 4, a pressurized water reactor (PWR) of 2815-MW(thermal) power in Korea, were reviewed, and possible event sequences were identified. From the CCT analysis for the five cases of typical plant configurations, it was estimated for the earliest CCT to be 40 min after the event in a case with a large cold-leg opening and emptied steam generators (SGs). However, the case with water-filled SGs significantly delayed the CCT through the heat removal to the secondary side. From the GIPR analysis for the six possible gravity-injection paths from the refueling water storage tank (RWST), the case with the injection point and opening on the other leg side was estimated to be the most suitable path to avoid core boiling. In addition, from the sensitivity study, it was evaluated for the plant to be capable of providing the core cooling for the long-term transient if nominal RWST water is available. As a result, these analysis methods and results will provide useful information in understanding the plant behavior and preparing the mitigation measures after the event, especially for Combustion Engineering-type PWR plants. However, to directly apply the analysis results to the emergency procedure for such an event, additional case studies are needed for a wide range of operating conditions such as reactor coolant inventory, RWST water temperature, and core decay heat rate.

  18. Use of DRACS to Enhance HTGRs Passive Safety and Economy

    SciTech Connect

    Haihua Zhao; Hongbin Zhang; Ling Zou

    2011-06-01

    This paper discusses the use of DRACS to Enhance HTGRs Passive Safety and Economy. One of the important requirements for Gen. IV High Temperature Gas Cooled Reactors (HTGR) is passive safety. Currently all the HTGR designs use Reactor Vessel Auxiliary Cooling System (RVACS) for passive decay heat removal. [1] The decay heat first is transferred to core barrel by conduction and radiation, and then to reactor vessel by thermal radiation and convection; finally the decay heat is transferred to natural circulated air or water systems. RVACS can be characterized as a surface based decay heat removal system. Similar concepts have been widely used in sodium cooled fast reactor (SFR) designs, advanced light water reactors like AP1000. The RVACS is especially suitable for smaller power reactors since small systems have relatively larger surface area. RVACS tends to be less expensive. However, it limits the largest achievable power level for modular HTGRs due to the mismatch between the reactor power (proportional to volume) and decay heat removal capability (proportional to surface). When the relative decay heat removal capability is reduced, the peak fuel temperature increases, even close to the design limit. Annual designs with internal reflector can mitigate this effect therefore further increase the power. Another way to increase power is to increase power density. However, it is also limited by the decay heat removal capability. Besides safety, HTGRs also need to be economical in order to compete with other reactor designs. The limit of decay heat removal capability set by using RVACS has affected the economy of HTGRs. Forsberg [2] pointed out other disadvantages of using RVACS such as conflicting functional requirements for the reactor vessel and scaling distortion for integral effect test of the system performance. A potential alternative solution is to use a volume based passive decay removal system, call Direct Reactor Auxiliary Cooling Systems (DRACS), to remove

  19. Detection of heat-stable antigens of Campylobacter jejuni and C. coli by direct agglutination and passive hemagglutination.

    PubMed

    Oza, A N; Thwaites, R T; Wareing, D R A; Bolton, F J; Frost, J A

    2002-03-01

    The two serotyping schemes for the detection of heat-stable antigens of Campylobacter jejuni and Campylobacter coli use the same strains for antiserum production but differ in the detection systems used for identifying agglutination. The Penner method uses passive hemagglutination (PHA) while the Laboratory of Enteric Pathogens method uses the same antisera but in a whole-bacterial-cell direct agglutination (DA) protocol. C. jejuni produces a polysaccharide capsule, which is antigenic, and is the main component detected by the PHA method. The DA method will detect both capsule antigens and lipopolysaccharide (LPS) or lipooligosaccharide (LOS) surface antigens. Comparison of both methods by using a selection of isolates from human infection has shown a range of variation in agglutination specificity, reflecting the differences in antigens detected by the two methods. While 27.4% of the 416 C. jejuni isolates reacted with the antisera raised against the same type strains by either method, the majority showed a range of more complex relationships. None of the 37 C. coli isolates reacted with the same antiserum by both methods. Together the two schemes gave a total of 102 distinct combined serogroups for C. jejuni and 16 for C. coli. Thus, while some clonally related isolates share the same capsule and LOS or LPS antigens, other strains appear to have a common capsule antigen but differ in their LPS or LOS structures or vice versa.

  20. Hepatic heat shock protein 70 and plasma cortisol levels in rainbow trout after tagging with a passive integrated transponder

    USGS Publications Warehouse

    Feldhaus, J.W.; Heppell, S.A.; Mesa, M.G.; Li, H.

    2008-01-01

    This study examined the potentially stressful effects of tagging juvenile rainbow trout Oncorhynchus mykiss with passive integrated transponder (PIT) tags by measuring short-term (<120-h) changes in plasma concentrations of cortisol and hepatic heat shock protein 70 (hsp70). In a laboratory experiment, plasma cortisol levels were measured in fish before they were tagged (0 h) and at 2, 6, 24, and 120 h after being tagged. Hepatic hsp70 levels were measured at 0, 24, and 120 h. All results were compared with those for fish that were handled but not tagged. Plasma cortisol levels were significantly higher in both treatment groups (tagged and handled but not tagged) at 2 h than in the pretreatment groups (0 h). Plasma cortisol levels in the treatment groups returned to near pretreatment levels by 6 h. However, there was a significant difference in plasma cortisol levels between treatment groups at 6 h. There were no significant differences in hepatic hsp70 levels among the two treatment groups, and hepatic hsp70 levels did not change through time. Our results suggest that PIT tagging is a low-impact tagging procedure for juvenile salmonids. ?? Copyright by the American Fisheries Society 2008.

  1. Multiple pollutant removal using the condensing heat exchanger: Preliminary test plan for Task 2, Pilot scale IFGT testing

    SciTech Connect

    Jankura, B.J.

    1995-11-01

    The purpose of Task 2 (IFGT Pilot-Scale Tests at the B&W Alliance Research Center) is to evaluate the emission reduction performance of the Integrated Flue Gas Treatment (IFGT) process for coal-fired applications. The IFGT system is a two-stage condensing heat exchanger that captures multiple pollutants -- while recovering waste heat. The IFGT technology offers the potential of addressing the emission of S0{sub 2} and particulate from electric utilities currently regulated under the Phase 1 and Phase 2 requirements defined in Title IV, and many of the air pollutants that will soon be regulated under Title III of the Clean Air Act. The performance data will be obtained at pilot-scale conditions similar to full-scale operating systems. The Task 2 IFGT tests have been designed to investigate several aspects of IFGT process conditions at a broader range of variables than would be feasible at a larger scale facility. The data from these tests greatly expands the IFGT performance database for coals and is needed for the technology to progress from the component engineering phase to system integration and commercialization. The performance parameters that will be investigated are as follows: SO{sub 2} removal; particulate removal; removal of mercury and other heavy metals; NO{sub x} removal; HF and HCl removal; NH{sub 3} removal; ammonia-sulfur compounds generation; and steam injection for particle removal. For all of the pollutant removal tests, removal efficiency will be based on measurements at the inlet and outlet of the IFGT facility. Heat recovery measurements will also be made during these tests to demonstrate the heat recovery provided by the IFGT technology. This report provides a preliminary test plan for all of the Task 2 pilot-scale IFGT tests.

  2. Thermal-hydraulic processes involved in loss of residual heat removal during reduced inventory operation

    SciTech Connect

    Fletcher, C.D.; McHugh, P.R.; Naff, S.A.; Johnsen, G.W.

    1991-02-01

    This paper identifies the topics needed to understand pressurized water reactor response to an extended loss of residual heat removal event during refueling and maintenance outages. By identifying the possible plant conditions and cooling methods that would be used for each cooling mode, the controlling thermal-hydraulic processes and phenomena were identified. Controlling processes and phenomena include: gravity drain, core water boil-off, and reflux cooling processes. Important subcategories of the reflux cooling processes include: the initiation of reflux cooling from various plant conditions, the effects of air on reflux cooling, core level depression effects, issues regarding the steam generator secondaries, and the special case of boiler-condenser cooling with once-through steam generators. 25 refs., 6 figs., 1 tab.

  3. Evaluation of contaminant removal of reverse osmosis and advanced oxidation in full-scale operation by combining passive sampling with chemical analysis and bioanalytical tools.

    PubMed

    Escher, Beate I; Lawrence, Michael; Macova, Miroslava; Mueller, Jochen F; Poussade, Yvan; Robillot, Cedric; Roux, Annalie; Gernjak, Wolfgang

    2011-06-15

    Advanced water treatment of secondary treated effluent requires stringent quality control to achieve a water quality suitable for augmenting drinking water supplies. The removal of micropollutants such as pesticides, industrial chemicals, endocrine disrupting chemicals (EDC), pharmaceuticals, and personal care products (PPCP) is paramount. As the concentrations of individual contaminants are typically low, frequent analytical screening is both laborious and costly. We propose and validate an approach for continuous monitoring by applying passive sampling with Empore disks in vessels that were designed to slow down the water flow, and thus uptake kinetics, and ensure that the uptake is only marginally dependent on the chemicals' physicochemical properties over a relatively narrow molecular size range. This design not only assured integrative sampling over 27 days for a broad range of chemicals but also permitted the use of a suite of bioanalytical tools as sum parameters, representative of mixtures of chemicals with a common mode of toxic action. Bioassays proved to be more sensitive than chemical analysis to assess the removal of organic micropollutants by reverse osmosis, followed by UV/H₂O₂ treatment, as many individual compounds fell below the quantification limit of chemical analysis, yet still contributed to the observed mixture toxicity. Nonetheless in several cases, the responses in the bioassays were also below their quantification limits and therefore only three bioassays were evaluated here, representing nonspecific toxicity and two specific end points for estrogenicity and photosynthesis inhibition. Chemical analytical techniques were able to quantify 32 pesticides, 62 PCPPs, and 12 EDCs in reverse osmosis concentrate. However, these chemicals could explain only 1% of the nonspecific toxicity in the Microtox assay in the reverse osmosis concentrate and 0.0025% in the treated water. Likewise only 1% of the estrogenic effect in the E-SCREEN could be

  4. Evaluation of contaminant removal of reverse osmosis and advanced oxidation in full-scale operation by combining passive sampling with chemical analysis and bioanalytical tools.

    PubMed

    Escher, Beate I; Lawrence, Michael; Macova, Miroslava; Mueller, Jochen F; Poussade, Yvan; Robillot, Cedric; Roux, Annalie; Gernjak, Wolfgang

    2011-06-15

    Advanced water treatment of secondary treated effluent requires stringent quality control to achieve a water quality suitable for augmenting drinking water supplies. The removal of micropollutants such as pesticides, industrial chemicals, endocrine disrupting chemicals (EDC), pharmaceuticals, and personal care products (PPCP) is paramount. As the concentrations of individual contaminants are typically low, frequent analytical screening is both laborious and costly. We propose and validate an approach for continuous monitoring by applying passive sampling with Empore disks in vessels that were designed to slow down the water flow, and thus uptake kinetics, and ensure that the uptake is only marginally dependent on the chemicals' physicochemical properties over a relatively narrow molecular size range. This design not only assured integrative sampling over 27 days for a broad range of chemicals but also permitted the use of a suite of bioanalytical tools as sum parameters, representative of mixtures of chemicals with a common mode of toxic action. Bioassays proved to be more sensitive than chemical analysis to assess the removal of organic micropollutants by reverse osmosis, followed by UV/H₂O₂ treatment, as many individual compounds fell below the quantification limit of chemical analysis, yet still contributed to the observed mixture toxicity. Nonetheless in several cases, the responses in the bioassays were also below their quantification limits and therefore only three bioassays were evaluated here, representing nonspecific toxicity and two specific end points for estrogenicity and photosynthesis inhibition. Chemical analytical techniques were able to quantify 32 pesticides, 62 PCPPs, and 12 EDCs in reverse osmosis concentrate. However, these chemicals could explain only 1% of the nonspecific toxicity in the Microtox assay in the reverse osmosis concentrate and 0.0025% in the treated water. Likewise only 1% of the estrogenic effect in the E-SCREEN could be

  5. Removal of FePO4 and Fe3(PO4)2 crystals on the surface of passive fillers in Fe0/GAC reactor using the acclimated bacteria.

    PubMed

    Lai, Bo; Zhou, Yuexi; Yang, Ping; Wang, Juling; Yang, Jinghui; Li, Huiqiang

    2012-11-30

    As past studies presented, there is obvious defect that the fillers in the Fe(0)/GAC reactor begin to be passive after about 60 d continuous running, although the complicated, toxic and refractory ABS resin wastewater can be pretreated efficiently by the Fe(0)/GAC reactor. During the process, the Fe(3)(PO(4))(2) and FePO(4) crystals with high density in the passive film are formed by the reaction between PO(4)(3-) and Fe(2+)/Fe(3+). Meanwhile, they obstruct the formation of macroscopic galvanic cells between Fe(0) and GAC, which will lower the wastewater treatment efficiency of Fe(0)/GAC reactor. In this study, in order to remove the Fe(3)(PO(4))(2) and FePO(4) crystals on the surface of the passive fillers, the bacteria were acclimated in the passive Fe(0)/GAC reactor. According to the results, it can be concluded that the Fe(3)(PO(4))(2) and FePO(4) crystals with high density in the passive film could be decomposed or removed by the joint action between the typical propionic acid type fermentation bacteria and sulfate reducing bacteria (SRB), whereas the PO(4)(3-) ions from the decomposition of the Fe(3)(PO(4))(2) and FePO(4) crystals were released into aqueous solution which would be discharged from the passive Fe(0)/GAC reactor. Furthermore, the remained FeS and sulfur (S) in the passive film also can be decomposed or removed easily by the oxidation of the sulfur-oxidizing bacteria. This study provides some theoretical references for the further study of a cost-effective bio-regeneration technology to solve the passive problems of the fillers in the zero-valent iron (ZVI) or Fe(0)/GAC reactor.

  6. Capillary-Pumped Passive Reactor Concept for Space Nuclear Power

    SciTech Connect

    Dr. Thomas F. Lin; Dr. Thomas G. Hughes; Christopher G. Miller

    2008-05-30

    To develop the passively-cooled space reactor concept using the capillary-induced lithium flow, since molten lithium possesses a very favorable surface tension characteristic. In space where the gravitational field is minimal, the gravity-assisted natural convection cooling is not effective nor an option for reactor heat removal, the capillary induced cooling becomes an attractive means of providing reactor cooling.

  7. Thermophysiological responses induced by a body heat removal system with Peltier devices in a hot environment.

    PubMed

    Suzurikawa, Jun; Fujimoto, Sho; Mikami, Kousei; Jonai, Hiroshi; Inoue, Takenobu

    2013-01-01

    Individuals with spinal cord injuries often experience thermoregulation disorders as well as sensory and motor disabilities. In order to prevent such individuals from becoming hyperthermic, we developed a body heat removal system (BHRS) with thermoelectric devices. Our BHRS comprises four Peltier devices mounted on a wheelchair backrest and continuously transfers body heat through the contacting interface to the external environment. Here, we characterized thermophysiological responses induced by this novel contact-type cooling system. A cooling experiment in a hot environment with five able-bodied subjects demonstrated that sweating and systolic blood pressure in the back-cooling (BC) trial were significantly suppressed compared with those in no-cooling (NC) trial, while no difference was found in oral and skin temperatures. A correlation was observed between chest skin temperature and blood flow in the NC trial; this was not observed in the BC trial. These results suggest that BHRS modulates normal thermoregulatory responses, including sweating and vascular dilation and has the capability to partly replace these functions.

  8. Optimization of residual heat removal pump axial thrust and axial bearing

    SciTech Connect

    Schubert, F.

    1996-12-01

    The residual heat removal (RHR) pumps of German 1300 megawatt pressurized-water reactor (PWR) power plants are of the single stage end suction type with volute casing or with diffuser and forged circular casing. Due to the service conditions the pumps have to cover the full capacity range as well as a big variation in suction static pressure. This results in a big difference in the axial thrust that has to be borne by the axial bearing. Because these pumps are designed to operate without auxiliary systems (things that do not exist can not fail), they are equipped with antifriction bearings and sump oil lubrication. To minimize the heat production within the bearing casing, a number of PWR plants have pumps with combined axial/radial bearings of the ball type. Due to the fact that the maximum axial thrust caused by static pressure and hydrodynamic forces on the impeller is too big to be borne by that type of axial bearing, the impellers were designed to produce a hydrodynamic axial force that counteracts the static axial force. Thus, the resulting axial thrust may change direction when the static pressure varies.

  9. Attached-sunspace passive solar-heated residences: A study of nationwide patterns of economic feasibility for the existing housing stock

    NASA Astrophysics Data System (ADS)

    Roach, F.; Kirschner, C.

    1981-06-01

    Performance estimates for attached-sunspace passive solar-heated residences were incorporated into the Los Alamos/UNM EASE 3 Model. These estimates are used to analyze the economic performance of a passive sunspace design when retrofitting onto an existing single-family home. Several key parameters are evaluated, including loan or mortgage terms, ownership period, resale potential, and competing conventional fuel prices. General economic and design parameters are combined in one version of life-cycle costing to evaluate the feasibility of both owner-built and contractor-built attached sunspaces for 220 regions in the contiguous US. The conventional fuel alternatives are natural gas, heating oil, electric resistance, and electric heat pump. The optimal sunspace design in determined for the fuel alternatives by minimizing the combined solar and conventional delivered cost of heat. An analysis of fuel used for space heating in existing homes is used to discuss the retrofit potential for the 220 regions. Results show that the prospect for conventional fuel displacement through retrofit of attached sunspace is very good, and that the design's economic performance is enhanced in regions with expensive conventional fuel alternatives.

  10. Enhancing VHTR passive safety and economy with thermal radiation based direct reactor auxiliary cooling system

    SciTech Connect

    Zhao, H.; Zhang, H.; Zou, L.; Sun, X.

    2012-07-01

    One of the most important requirements for Gen. IV Very High Temperature Reactor (VHTR) is passive safety. Currently all the gas cooled version of VHTR designs use Reactor Vessel Auxiliary Cooling System (RVACS) for passive decay heat removal. The RVACS can be characterized as a surface-based decay heat removal system. It is especially suitable for smaller power reactors since small systems have relatively larger surface area to volume ratio. However, RVACS limits the maximum achievable power level for modular VHTRs due to the mismatch between the reactor power (proportional to the core volume) and decay heat removal capability (proportional to the vessel surface area). Besides the safety considerations, VHTRs also need to be economical in order to compete with other reactor concepts and other types of energy sources. The limit of decay heat removal capability set by using RVACS has affected the economy of VHTRs. A potential alternative solution is to use a volume-based passive decay heat removal system, called Direct Reactor Auxiliary Cooling Systems (DRACS), to remove or mitigate the limitation on decay heat removal capability. DRACS composes of natural circulation loops with two sets of heat exchangers, one on the reactor side and another on the environmental side. For the reactor side, cooling pipes will be inserted into holes made in the outer or inner graphite reflector blocks. There will be gaps or annular regions formed between these cooling pipes and their corresponding surrounding graphite surfaces. Graphite has an excellent heat conduction property. By taking advantage of this feature, we can have a volume-based method to remove decay heat. The scalability can be achieved, if needed, by employing more rows of cooling pipes to accommodate higher decay heat rates. Since heat can easily conduct through the graphite regions among the holes made for the cooling pipes, those cooling pipes located further away from the active core region can still be very

  11. On the passivation mechanism of Fe3O4 nanoparticles during Cr(VI) removal from water: A XAFS study

    NASA Astrophysics Data System (ADS)

    Pinakidou, F.; Katsikini, M.; Simeonidis, K.; Kaprara, E.; Paloura, E. C.; Mitrakas, M.

    2016-01-01

    X-Ray Absorption Spectroscopies (XAFS) are employed in order to gather a thorough insight on the uptake mechanism of Cr(VI) by Fe3O4 nanoparticles under water treatment conditions. The XANES measurements identify that the reducing potential of Fe3O4 activates the precipitation of Cr(VI) in the form of insoluble and non-toxic Cr(III). However, electron donation from Fe(II) is responsible for its gradual consumption, resulting in the presence of a surface maghemite layer and the formation of structural vacancies. EXAFS analysis reveal that adsorption of Cr(III)-oxyanions occurs on sorption sites provided by the vacancies in the maghemite layer, where Cr(III) is involved in a bidentate binuclear (2E) geometry with Fe-octahedra while it also forms monodentate (1V) complexes with the Fe(III)O4 tetrahedra. The surface maghemitization along with the reduced Cr(III) adsorption into the vacancies, tracks the degree of Cr-reduction, since this surface structural modifications hinder Cr(VI) access to the Fe(II) ions of the magnetite nanoparticles. Thus, high surface coverage leads to the passivation of the reduction ability since physisorbed Cr(VI) is also detected through the formation of outer sphere complexes.

  12. A concept of JAERI passive safety light water reactor system (JPSR)

    SciTech Connect

    Murao, Y.; Araya, F.; Iwamura, T.

    1995-09-01

    The Japan Atomic Energy Research Institute (JAERI) proposed a passive safety reactor system concept, JPSR, which was developed for reducing manpower in operation and maintenance and influence of human errors on reactor safety. In the concept the system was extremely simplified. The inherent matching nature of core generation and heat removal rate within a small volume change of the primary coolant is introduced by eliminating chemical shim and adopting in-vessel control rod drive mechanism units, a low power density core and once-through steam generators. In order to simplify the system, a large pressurizer, canned pumps, passive engineered-safety-features-system (residual heat removal system and coolant injection system) are adopted and the total system can be significantly simplified. The residual heat removal system is completely passively actuated in non-LOCAs and is also used for depressurization of the primary coolant system to actuate accumulators in small break LOCAs and reactor shutdown cooling system in normal operation. All of systems for nuclear steam supply system are built in the containment except for the air coolers as a the final heat sink of the passive residual heat removal system. Accordingly the reliability of the safety system and the normal operation system is improved, since most of residual heat removal system is always working and a heat sink for normal operation system is {open_quotes}safety class{close_quotes}. In the passive coolant injection system, depressurization of the primary cooling system by residual heat removal system initiates injection from accumulators designed for the MS-600 in medium pressure and initiates injection from the gravity driven coolant injection pool at low pressure. Analysis with RETRAN-02/MOD3 code demonstrated the capability of passive load-following, self-power-controllability, cooling and depressurization.

  13. Effectiveness of conventional syringe irrigation, vibringe, and passive ultrasonic irrigation performed with different irrigation regimes in removing triple antibiotic paste from simulated root canal irregularities

    PubMed Central

    Topçuoğlu, Hüseyin Sinan; Aktı, Ahmet; Topçuoğlu, Gamze; Düzgün, Salih; Ulusan, Özge; Akpek, Firdevs

    2016-01-01

    Background: This study evaluated the efficacy of a sonic device (Vibringe), passive ultrasonic irrigation (PUI), and conventional syringe irrigation (CSI) in the removal of triple antibiotic paste (TAP) from artificial standardized grooves in the apical and coronal thirds of a root canal. Materials and Methods: One-hundred eighteen root canals were prepared using the ProTaper system. The roots were split longitudinally, and a standardized groove was prepared in the apical and coronal parts of one segment. The grooves were filled with TAP, and the roots were reassembled. The roots were randomly divided into nine experimental groups and two control groups, according to the following irrigation methods: (1) CSI with sodium hypochlorite (NaOCl) + ethylenediaminetetraacetic acid (EDTA), (2) CSI/EDTA, (3) CSI/NaOCl, (4) PUI/NaOCl + EDTA, (5) PUI/EDTA, (6) PUI/NaOCl, (7) Vibringe/NaOCl + EDTA, (8) Vibringe/EDTA, and (9) Vibringe/NaOCl. The amount of remaining medicament was evaluated under a stereomicroscope. Results: In the apical third, Vibringe/NaOCl + EDTA and PUI/NaOCl + EDTA were superior to the other groups (P < 0.05); there was no significant difference between the other experimental groups (P > 0.05). In the coronal third, there was no significant difference between the experimental groups (P > 0.05). Conclusions: The use of the NaOCl/EDTA combination together with sonic or ultrasonic agitation improved the removal of TAP from the apical third. PMID:27563179

  14. A Passive EMI Filter with Access to the Ungrounded Motor Neutral Line-Its Effect on Eliminating Leakage Current from the Inverter Heat Sink-

    NASA Astrophysics Data System (ADS)

    Doumoto, Takafumi; Akagi, Hirofumi

    This paper deals with a leakage current flowing out of the heat sink of a voltage-source PWM inverter. The heat-sink leakage current is caused by a steep change in the common-mode voltage produced by the inverter. It flows through parasitic capacitors between the heat sink and power semiconductor devices when no EMI filter is connected. Experimental results reveal that the heat-sink leakage current flows not into the supply side, but into the motor side. These understandings succeed in describing an equivalent common-mode circuit taking the parasitic capacitors into account. The authors have proposed a passive EMI filter that is unique in access to the ungrounded motor neutral line. It is discussed from this equivalent circuit that the passive EMI filter is effective in preventing the leakage current from flowing. Moreover, installation of another small-sized common-mode inductor at the ac side of the diode rectifier prevents the leakage current from flowing into the supply side. Experimental results obtained from a 200-V, 3.7-kW laboratory system confirm the effectiveness and viability of the EMI filter.

  15. Temperature initiated passive cooling system

    DOEpatents

    Forsberg, C.W.

    1994-11-01

    A passive cooling system for cooling an enclosure only when the enclosure temperature exceeds a maximum standby temperature comprises a passive heat transfer loop containing heat transfer fluid having a particular thermodynamic critical point temperature just above the maximum standby temperature. An upper portion of the heat transfer loop is insulated to prevent two phase operation below the maximum standby temperature. 1 fig.

  16. Temperature initiated passive cooling system

    DOEpatents

    Forsberg, Charles W.

    1994-01-01

    A passive cooling system for cooling an enclosure only when the enclosure temperature exceeds a maximum standby temperature comprises a passive heat transfer loop containing heat transfer fluid having a particular thermodynamic critical point temperature just above the maximum standby temperature. An upper portion of the heat transfer loop is insulated to prevent two phase operation below the maximum standby temperature.

  17. Passive heat exposure induced by hot water leg immersion increased oxyhemoglobin in pre-frontal cortex to preserve oxygenation and did not contribute to impaired cognitive functioning.

    PubMed

    Wijayanto, Titis; Toramoto, Sayo; Tochihara, Yutaka

    2013-07-01

    This study investigated the effects of passive heat exposure on pre-frontal cortex oxygenation and cognitive functioning, specifically to examine whether the change in pre-frontal cortex oxygenation coincided with cognitive functioning during heat exposure. Eleven male students who participated in this study immersed their lower legs to the knees in three different water temperatures, 38 °C, 40 °C, and 42 °C water in an air temperature of 28 º C and 50 % relative humidity for 60 min. After 45 min of leg immersion they performed cognitive functioning tasks assessing their short-term memory while immersing their lower legs. There were higher rectal temperature (P < 0.05) and higher increase of oxyhemoglobin in both left (P < 0.05) and right (P < 0.05) pre-frontal cortex at the final stage of 45-min leg immersion in the 42 °C condition with unaltered tissue oxygenation index among the three conditions (P > 0.05). No statistical difference in cognitive functioning among the three conditions was observed with a higher increase of oxyhemoglobin during the cognitive functioning in the 42 °C condition for the left (P = 0.05) and right (P < 0.05) pre-frontal cortex. The findings of this study suggest, first, passive heat exposure increases oxygen delivery in the pre-frontal cortex to maintain pre-frontal cortex oxygenation; second, there is no evidence of passive heat exposure in cognitive functioning in this study; and third, the greater increases of oxyhemoglobin in the pre-frontal cortex during cognitive functioning at the hottest condition suggests a recruitment of available neural resources or greater effort to maintain the same performance at the same level as when they felt thermally comfortable.

  18. Passive heat exposure induced by hot water leg immersion increased oxyhemoglobin in pre-frontal cortex to preserve oxygenation and did not contribute to impaired cognitive functioning

    NASA Astrophysics Data System (ADS)

    Wijayanto, Titis; Toramoto, Sayo; Tochihara, Yutaka

    2013-07-01

    This study investigated the effects of passive heat exposure on pre-frontal cortex oxygenation and cognitive functioning, specifically to examine whether the change in pre-frontal cortex oxygenation coincided with cognitive functioning during heat exposure. Eleven male students who participated in this study immersed their lower legs to the knees in three different water temperatures, 38 °C, 40 °C, and 42 °C water in an air temperature of 28 º C and 50 % relative humidity for 60 min. After 45 min of leg immersion they performed cognitive functioning tasks assessing their short-term memory while immersing their lower legs. There were higher rectal temperature ( P < 0.05) and higher increase of oxyhemoglobin in both left ( P < 0.05) and right ( P < 0.05) pre-frontal cortex at the final stage of 45-min leg immersion in the 42 °C condition with unaltered tissue oxygenation index among the three conditions ( P > 0.05). No statistical difference in cognitive functioning among the three conditions was observed with a higher increase of oxyhemoglobin during the cognitive functioning in the 42 °C condition for the left ( P = 0.05) and right ( P < 0.05) pre-frontal cortex. The findings of this study suggest, first, passive heat exposure increases oxygen delivery in the pre-frontal cortex to maintain pre-frontal cortex oxygenation; second, there is no evidence of passive heat exposure in cognitive functioning in this study; and third, the greater increases of oxyhemoglobin in the pre-frontal cortex during cognitive functioning at the hottest condition suggests a recruitment of available neural resources or greater effort to maintain the same performance at the same level as when they felt thermally comfortable.

  19. Quantitative analysis of methamphetamine in hair of children removed from clandestine laboratories--evidence of passive exposure?

    PubMed

    Bassindale, T

    2012-06-10

    In New Zealand many children have been removed from clandestine laboratories following Police intervention. In the last few years it has become standard procedure that these children have hair samples taken and these samples are submitted to the laboratory for analysis. There are various mechanisms for the incorporation of drugs into hair. The hair follicle has a rich blood supply, so any drug that may be circulating in the blood can be incorporated into the growing hair. Another mechanism is via external contamination, such as spilling a drug on the hair or through exposure to fumes or vapours. Hair samples were analysed for methamphetamine and amphetamine. From the 52 cases analysed 38 (73%) were positive for methamphetamine (>0.1 ng/mg) and amphetamine was detected in 34 of these cases. In no case was amphetamine detected without methamphetamine. The hair washes (prior to extraction) were also analysed (quantified in 30 of the positive cases) and only 3 had a wash to hair ratio of >0.1 (all were <0.5), which may be indicative of a low level of external contamination. This low level of evidence of external contamination suggests that the children are exposed to methamphetamine and are incorporating it into the hair through the blood stream.

  20. Fly ash carbon passivation

    DOEpatents

    La Count, Robert B; Baltrus, John P; Kern, Douglas G

    2013-05-14

    A thermal method to passivate the carbon and/or other components in fly ash significantly decreases adsorption. The passivated carbon remains in the fly ash. Heating the fly ash to about 500 and 800 degrees C. under inert gas conditions sharply decreases the amount of surfactant adsorbed by the fly ash recovered after thermal treatment despite the fact that the carbon content remains in the fly ash. Using oxygen and inert gas mixtures, the present invention shows that a thermal treatment to about 500 degrees C. also sharply decreases the surfactant adsorption of the recovered fly ash even though most of the carbon remains intact. Also, thermal treatment to about 800 degrees C. under these same oxidative conditions shows a sharp decrease in surfactant adsorption of the recovered fly ash due to the fact that the carbon has been removed. This experiment simulates the various "carbon burnout" methods and is not a claim in this method. The present invention provides a thermal method of deactivating high carbon fly ash toward adsorption of AEAs while retaining the fly ash carbon. The fly ash can be used, for example, as a partial Portland cement replacement in air-entrained concrete, in conductive and other concretes, and for other applications.

  1. Experimental evaluation of a breadboard heat and product-water removal system for a space-power fuel cell designed with static water removal and evaporative cooling

    NASA Technical Reports Server (NTRS)

    Hagedorn, N. H.; Prokipius, P. R.

    1977-01-01

    A test program was conducted to evaluate the design of a heat and product-water removal system to be used with fuel cell having static water removal and evaporative cooling. The program, which was conducted on a breadboard version of the system, provided a general assessment of the design in terms of operational integrity and transient stability. This assessment showed that, on the whole, the concept appears to be inherently sound but that in refining this design, several facets will require additional study. These involve interactions between pressure regulators in the pumping loop that occur when they are not correctly matched and the question of whether an ejector is necessary in the system.

  2. Removal of As, Mn, Mo, Se, U, V and Zn from groundwater by zero-valent iron in a passive treatment cell: reaction progress modeling.

    PubMed

    Morrison, Stan J; Metzler, Donald R; Dwyer, Brian P

    2002-05-01

    Three treatment cells were operated at a site near Durango, CO. One treatment cell operated for more than 3 years. The treatment cells were used for passive removal of contamination from groundwater at a uranium mill tailings repository site. Zero-valent iron [Fe(0)] that had been powdered, bound with aluminosilicate and molded into plates was used as a reactive material in one treatment cell. The others used granular Fe(0) and steel wool. The treatment cells significantly reduced concentrations of As, Mn, Mo, Se, U, V and Zn in groundwater that flowed through it. Zero-valent iron [Fe(0)], magnetite (Fe3O4), calcite (CaCO3), goethite (FeOOH) and mixtures of contaminant-bearing phases were identified in the solid fraction of one treatment cell. A reaction progress approach was used to model chemical evolution of water chemistry as it reacted with the Fe(0). Precipitation of calcite, ferrous hydroxide [Fe(OH)2] and ferrous sulfide (FeS) were used to simulate observed changes in major-ion aqueous chemistry. The amount of reaction progress differed for each treatment cell. Changes in contaminant concentrations were consistent with precipitation of reduced oxides (UO2, V2O3), sulfides (As2S3, ZnS), iron minerals (FeSe2, FeMoO4) and carbonate (MnCO3). Formation of a free gas phase and precipitation of minerals contributed to loss of hydraulic conductivity in one treatment cell.

  3. GaN as an interfacial passivation layer: tuning band offset and removing fermi level pinning for III-V MOS devices.

    PubMed

    Zhang, Zhaofu; Cao, Ruyue; Wang, Changhong; Li, Hao-Bo; Dong, Hong; Wang, Wei-Hua; Lu, Feng; Cheng, Yahui; Xie, Xinjian; Liu, Hui; Cho, Kyeongjae; Wallace, Robert; Wang, Weichao

    2015-03-11

    The use of an interfacial passivation layer is one important strategy for achieving a high quality interface between high-k and III-V materials integrated into high-mobility metal-oxide-semiconductor field-effect transistor (MOSFET) devices. Here, we propose gallium nitride (GaN) as the interfacial layer between III-V materials and hafnium oxide (HfO2). Utilizing first-principles calculations, we explore the structural and electronic properties of the GaN/HfO2 interface with respect to the interfacial oxygen contents. In the O-rich condition, an O8 interface (eight oxygen atoms at the interface, corresponding to 100% oxygen concentration) displays the most stability. By reducing the interfacial O concentration from 100 to 25%, we find that the interface formation energy increases; when sublayer oxygen vacancies exist, the interface becomes even less stable compared with O8. The band offset is also observed to be highly dependent on the interfacial oxygen concentration. Further analysis of the electronic structure shows that no interface states are present at the O8 interface. These findings indicate that the O8 interface serves as a promising candidate for high quality III-V MOS devices. Moreover, interfacial states are present when such interfacial oxygen is partially removed. The interface states, leading to Fermi level pinning, originate from unsaturated interfacial Ga atoms. PMID:25639492

  4. Design tool survey. IEA Solar Heating and Cooling - Task 8. Passive and hybrid solar low-energy buildings, Subtask C: design methods

    SciTech Connect

    Rittelmann, P.R.; Ahmed, S.F.

    1985-05-01

    This document presents the results of a survey of design tools conducted as part of Subtask C (Design Methods) of Task VIII of the IAE Solar Heating and Cooling Program. At the start of the task, the participants agreed that it would be useful to identify and characterize the various design tools which existed for predicting the energy performance of passive and hybrid solar low energy buildings. A standard survey form was adopted, and Subtask C representatives from the member countries collected and submitted information on the design tools in use in each country. These responses were compiled into the present survey document.

  5. A 31 mW, 280 fs passively mode-locked fiber soliton laser using a high heat-resistant SWNT/P3HT saturable absorber coated with siloxane.

    PubMed

    Ono, Takato; Hori, Yuichiro; Yoshida, Masato; Hirooka, Toshihiko; Nakazawa, Masataka; Mata, Junji; Tsukamoto, Jun

    2012-10-01

    We report a substantial increase in the heat resistance in a connector-type single-wall carbon nanotube (SWNT) saturable absorber by sealing SWNT/P3HT composite with siloxane. By applying the saturable absorber to a passively mode-locked Er fiber laser, we successfully demonstrated 280 fs, 31 mW pulse generation with a fivefold improvement in heat resistance.

  6. Institute for High Heat Flux Removal (IHHFR). Phases I, II, and III

    SciTech Connect

    Boyd, Ronald D.

    2014-08-31

    The IHHFR focused on interdisciplinary applications as it relates to high heat flux engineering issues and problems which arise due to engineering systems being miniaturized, optimized, or requiring increased high heat flux performance. The work in the IHHFR focused on water as a coolant and includes: (1) the development, design, and construction of the high heat flux flow loop and facility; (2) test section development, design, and fabrication; and, (3) single-side heat flux experiments to produce 2-D boiling curves and 3-D conjugate heat transfer measurements for single-side heated test sections. This work provides data for comparisons with previously developed and new single-side heated correlations and approaches that address the single-side heated effect on heat transfer. In addition, this work includes the addition of single-side heated circular TS and a monoblock test section with a helical wire insert. Finally, the present work includes: (1) data base expansion for the monoblock with a helical wire insert (only for the latter geometry), (2) prediction and verification using finite element, (3) monoblock model and methodology development analyses, and (4) an alternate model development for a hypervapotron and related conjugate heat transfer controlling parameters.

  7. Feasibility study for use of the natural convection shutdown heat removal test facility (NSTF) for VHTR water-cooled RCCS shutdown.

    SciTech Connect

    Tzanos, C.P.; Farmer, M.T.; Nuclear Engineering Division

    2007-08-31

    -normal operating conditions. The standpipes are headered (in groups of four in the prototype) to water supply (header) tanks that are situated well above the reactor vessel to facilitate natural convection cooling during a loss of forced flow event. During normal operations, the water is pumped from a heat sink located outside the containment to the headered inlets to the standpipes. The water is then delivered to each standpipe through a centrally located downcomer that passes the coolant to the bottom of each pipe. The water then turns 180{sup o} and rises up through the annular gap while extracting heat from the reactor cavity due to a combination of natural convection and radiation across the gap between the reactor vessel and standpipes. The water exits the standpipes at the top where it is headered (again in groups of four) into a return line that passes the coolant to the top of the header tank. Coolant is drawn from each tank through a fitting located near the top of the tank where it flows to the heat rejection system located outside the containment. This completes the flow circuit for normal operations. During off-normal conditions, forced convection water cooling in the RCCS is presumed to be lost, as well as the ultimate heat sink outside the containment. In this case, water is passively drawn from an open line located at the bottom of the header tank. This line is orificed so that flow bypass during normal operations is small, yet the line is large enough to provide adequate flow during passive operations to remove decay heat while maintaining acceptable fuel temperatures. In the passive operating mode, water flows by natural convection from the bottom of the supply tank to the standpipes, and returns through the normal pathway to the top of the tanks. After the water reaches saturation and boiling commences, steam will pass through the top of the tanks and be vented to atmosphere. In the experiment system shown in Fig. 4, a steam condensation and collection system is

  8. Topical report : CFD analysis for the applicability of the natural convection shutdown heat removal test facility (NSTF) for the simulation of the VHTR RCCS.

    SciTech Connect

    Tzanos, C. P.

    2007-05-16

    The Very High Temperature gas cooled reactor (VHTR) is one of the GEN IV reactor concepts that have been proposed for thermochemical hydrogen production and other process-heat applications like coal gasification. The United States Department of Energy has selected the VHTR for further research and development, aiming to demonstrate emissions-free electricity and hydrogen production at a future time. One of the major safety advantages of the VHTR is the potential for passive decay heat removal by natural circulation of air in a Reactor Cavity Cooling System (RCCS). The air-side of the RCCS is very similar to the Reactor Vessel Auxiliary Cooling System (RVACS) that has been proposed for the PRISM reactor design. The design and safety analysis of the RVACS have been based on extensive analytical and experimental work performed at ANL. The Natural Convection Shutdown Heat Removal Test Facility (NSTF) at ANL that simulates at full scale the air-side of the RVACS was built to provide experimental support for the design and analysis of the PRISM RVACS system. The objective of this work is to demonstrate that the NSTF facility can be used to generate RCCS experimental data: to validate CFD and systems codes for the analysis of the RCCS; and to support the design and safety analysis of the RCCS. At this time no reference design is available for the NGNP. The General Atomics (GA) gas turbine - modular helium reactor (GT-MHR) has been used in many analyses as a starting reference design. In the GT-MHR the reactor outlet temperature is 850 C, while the target outlet reactor temperature in VHTR is 1000 C. VHTR scoping studies with a reactor outlet temperature of 1000 C have been performed at GA and INEL. Although the reactor outlet temperature in the VHTR is significantly higher than in the GT-MHR, the peak temperature in the reactor vessel (which is the heat source for the RCCS) is not drastically different. In this work, analyses have been performed using reactor vessel

  9. Pilot-scale passive bioreactors for the treatment of acid mine drainage: efficiency of mushroom compost vs. mixed substrates for metal removal.

    PubMed

    Song, Hocheol; Yim, Gil-Jae; Ji, Sang-Woo; Neculita, Carmen Mihaela; Hwang, Taewoon

    2012-11-30

    Pilot-scale field-testing of passive bioreactors was performed to evaluate the efficiency of a mixture of four substrates (cow manure compost, mushroom compost, sawdust, and rice straw) relative to mushroom compost alone, and of the effect of the Fe/Mn ratio, during the treatment of acid mine drainage (AMD) over a 174-day period. Three 141 L columns, filled with either mushroom compost or the four substrate mixture (in duplicate), were set-up and fed with AMD from a closed mine site, in South Korea, using a 4-day hydraulic retention time. In the former bioreactor, effluent deterioration was observed over 1-2 months, despite the good efficiency predicted by the physicochemical characterization of mushroom compost. Steady state effluent quality was then noted for around 100 days before worsening in AMD source water occurred in response to seasonal variations in precipitation. Such changes in AMD quality resulted in performance deterioration in all reactors followed by a slow recovery toward the end of testing. Both substrates (mushroom compost and mixtures) gave satisfactory performance in neutralizing pH (6.1-7.8). Moreover, the system was able to consistently reduce sulfate from day 49, after the initial leaching out from organic substrates. Metal removal efficiencies were on the order of Al (∼100%) > Fe (68-92%) > Mn (49-61%). Overall, the mixed substrates showed comparable performance to mushroom compost, while yielding better effluent quality upon start-up. The results also indicated mushroom compost could release significant amounts of Mn and sulfate during bioreactor operation.

  10. Coolability of stratified UO/sub 2/ debris in sodium with downward heat removal: The D13 experiment

    SciTech Connect

    Ottinger, C.A.; Mitchell, G.W.; Reed, A.W.; Meister, H.

    1987-03-01

    The LMFBR Debris Coolability Program at Sandia National Laboratories investigates the coolability of particle beds that may form following a severe accident involving core disassembly in a nuclear reactor. The D series experiments utilize fission heating of fully enriched UO/sub 2/ particles submerged in sodium to realistically simulate decay heating. The D13 experiment is the first in the series to study the effects of bottom cooling of stratified debris, which could be provided in an actual accident condition by structural materials onto which the debris might settle. Additionally, the D13 experiment was designed to achieve maximum temperatures in the debris approaching the melting point of UO/sub 2/. The experiment was operated for over 40 hours and investigated downward heat removal at specific powers of 0.22 to 2.58 W/g. Channeled dryout in the debris was achieved at powers from 0.94 to 2.58 W/g. Maximum temperatures approaching 2700/sup 0/C were attained. Bottom heat removal was up to 750 kW/m/sup 2/ as compared to 450 kW/m/sup 2/ in the D10 experiment.

  11. Experimental investigations on decay heat removal in advanced nuclear reactors using single heater rod test facility: Air alone in the annular gap

    SciTech Connect

    Bopche, Santosh B.; Sridharan, Arunkumar

    2010-11-15

    During a loss of coolant accident in nuclear reactors, radiation heat transfer accounts for a significant amount of the total heat transfer in the fuel bundle. In case of heavy water moderator nuclear reactors, the decay heat of a fuel bundle enclosed in the pressure tube and outer concentric calandria tube can be transferred to the moderator. Radiation heat transfer plays a significant role in removal of decay heat from the fuel rods to the moderator, which is available outside the calandria tube. A single heater rod test facility is designed and fabricated as a part of preliminary investigations. The objective is to anticipate the capability of moderator to remove decay heat, from the reactor core, generated after shut down. The present paper focuses mainly on the role of moderator in removal of decay heat, for situation with air alone in the annular gap of pressure tube and calandria tube. It is seen that the naturally aspirated air is capable of removing the heat generated in the system compared to the standstill air or stagnant water situations. It is also seen that the flowing moderator is capable of removing a greater fraction of heat generated by the heater rod compared to a stagnant pool of boiling moderator. (author)

  12. Development of Passive Fuel Cell Thermal Management Technology

    NASA Technical Reports Server (NTRS)

    Burke, Kenneth A.; Jakupca, Ian; Colozza, Anthony

    2011-01-01

    The NASA Glenn Research Center is developing advanced passive thermal management technology to reduce the mass and improve the reliability of space fuel cell systems for the NASA exploration program. The passive thermal management system relies on heat conduction within the cooling plate to move the heat from the central portion of the cell stack out to the edges of the fuel cell stack rather than using a pumped loop cooling system to convectively remove the heat. Using the passive approach eliminates the need for a coolant pump and other cooling loop components which reduces fuel cell system mass and improves overall system reliability. Previous analysis had identified that low density, ultra-high thermal conductivity materials would be needed for the cooling plates in order to achieve the desired reductions in mass and the highly uniform thermal heat sink for each cell within a fuel cell stack. A pyrolytic graphite material was identified and fabricated into a thin plate using different methods. Also a development project with Thermacore, Inc. resulted in a planar heat pipe. Thermal conductivity tests were done using these materials. The results indicated that lightweight passive fuel cell cooling is feasible.

  13. Influence of circulating cytokines on prolactin during slow vs. fast exertional heat stress followed by active or passive recovery.

    PubMed

    Wright, Heather E; McLellan, Tom M; Friesen, Brian J; Casa, Douglas J; Kenny, Glen P

    2012-08-15

    Prolactin (PRL) has been suggested as an indicator of fatigue during exertional heat stress (EHS), given its strong relationship with body core temperature (T(c)); however, the strength of this relationship during different rates of T(c) increase and subsequent recovery is unknown. In addition, given the influence that systemic cytokines, such as interleukin (IL)-6 and tumor necrosis factor (TNF)-α, have on the pituitary gland, it would be of interest to determine the relationship between PRL, IL-6, and TNF-α during EHS. The purpose was to examine the PRL, IL-6, and TNF-α heat stress responses during slow and fast heating and subsequent resting or cold water immersion recovery. On 4 days, nine individuals walked at ≈ 45% (slow heating) or ran at ≈ 65% (fast heating) maximal oxygen consumption on a treadmill in the heat (40°C, 30% relative humidity) until rectal temperature (T(re)) reached 39.5°C (esophageal temperature; fast = 39.41 ± 0.04°C, slow = 39.82 ± 0.09°C). Post-EHS, subjects were either immersed in 2°C water or rested seated until T(re) returned to 38.0°C. Venous blood, analyzed for PRL, IL-6, and TNF-α, was obtained at rest, during exercise (T(re) 38.0, 39.0, 39.5°C), the start of recovery (≈ 5 min after 39.5°C), and subsequent recovery (T(re) 39.0, 38.0°C). IL-6 exhibited myokine properties, given the greater increases with slow heating and lack of increase in TNF-α. A strong temperature-dependent PRL response during slow and fast heating provides additional support for the use of PRL as a peripheral marker of impending fatigue, which is independent of IL-6 and TNF-α cytokine responses.

  14. Passive Warming using a Heat-Band versus a Resistive Heating Blanket for the Prevention of Inadvertent Perioperative Hypothermia during Laparotomy for Gynaecological Surgery

    PubMed Central

    Wan Fadzlina, Wan Muhd Shukeri; Wan Mohd Nazaruddin, Wan Hassan; Rhendra Hardy, Mohamad Zaini

    2016-01-01

    Background Inadvertent perioperative hypothermia (IPH) is a common problem, despite advancements in a variety of warming systems. The use of a resistive heating blanket (RHB) is a common but costly approach to patient warming. We have introduced the use of a heat-band in our centre as a cost-effective alternative to the RHB for patient warming. The efficacy of the heat-band in preventing IPH during laparotomy for gynaecological surgeries was compared with that of the RHB. Methods Thirty-two patients undergoing surgeries under combined general-epidural anaesthesia, with an expected duration of surgery of 2–4 h, were randomised to receive either the heat-band or RHB. The core body temperatures of the two groups were compared at several perioperative times, in addition to the incidence of post-anaesthesia shivering, time to extubation and intraoperative blood loss. Results The core body temperatures were comparable between the two groups in the pre-operative period, immediately after the induction of anaesthesia and skin incision, 1 h after the incision, at the time of complete skin closing, at extubation, upon arrival to the recovery room and 1 h post-operatively. There were no significant between-group differences in the incidence of post-anaesthesia shivering, time to extubation and intra-operative blood loss. Conclusion The heat-band is as effective as the RHB in preventing IPH and its complications in gynaecological laparotomies. PMID:27547112

  15. Comparison of Tobacco Host Cell Protein Removal Methods by Blanching Intact Plants or by Heat Treatment of Extracts.

    PubMed

    Buyel, Johannes F; Hubbuch, Jürgen; Fischer, Rainer

    2016-01-01

    Plants not only provide food, feed and raw materials for humans, but have also been developed as an economical production system for biopharmaceutical proteins, such as antibodies, vaccine candidates and enzymes. These must be purified from the plant biomass but chromatography steps are hindered by the high concentrations of host cell proteins (HCPs) in plant extracts. However, most HCPs irreversibly aggregate at temperatures above 60 °C facilitating subsequent purification of the target protein. Here, three methods are presented to achieve the heat precipitation of tobacco HCPs in either intact leaves or extracts. The blanching of intact leaves can easily be incorporated into existing processes but may have a negative impact on subsequent filtration steps. The opposite is true for heat precipitation of leaf extracts in a stirred vessel, which can improve the performance of downstream operations albeit with major changes in process equipment design, such as homogenizer geometry. Finally, a heat exchanger setup is well characterized in terms of heat transfer conditions and easy to scale, but cleaning can be difficult and there may be a negative impact on filter capacity. The design-of-experiments approach can be used to identify the most relevant process parameters affecting HCP removal and product recovery. This facilitates the application of each method in other expression platforms and the identification of the most suitable method for a given purification strategy. PMID:27584939

  16. Comparison of Tobacco Host Cell Protein Removal Methods by Blanching Intact Plants or by Heat Treatment of Extracts.

    PubMed

    Buyel, Johannes F; Hubbuch, Jürgen; Fischer, Rainer

    2016-01-01

    Plants not only provide food, feed and raw materials for humans, but have also been developed as an economical production system for biopharmaceutical proteins, such as antibodies, vaccine candidates and enzymes. These must be purified from the plant biomass but chromatography steps are hindered by the high concentrations of host cell proteins (HCPs) in plant extracts. However, most HCPs irreversibly aggregate at temperatures above 60 °C facilitating subsequent purification of the target protein. Here, three methods are presented to achieve the heat precipitation of tobacco HCPs in either intact leaves or extracts. The blanching of intact leaves can easily be incorporated into existing processes but may have a negative impact on subsequent filtration steps. The opposite is true for heat precipitation of leaf extracts in a stirred vessel, which can improve the performance of downstream operations albeit with major changes in process equipment design, such as homogenizer geometry. Finally, a heat exchanger setup is well characterized in terms of heat transfer conditions and easy to scale, but cleaning can be difficult and there may be a negative impact on filter capacity. The design-of-experiments approach can be used to identify the most relevant process parameters affecting HCP removal and product recovery. This facilitates the application of each method in other expression platforms and the identification of the most suitable method for a given purification strategy.

  17. Enhancing VHTR Passive Safety and Economy with Thermal Radiation Based Direct Reactor Auxiliary Cooling System

    SciTech Connect

    Haihua Zhao; Hongbin Zhang; Ling Zou; Xiaodong Sun

    2012-06-01

    One of the most important requirements for Gen. IV Very High Temperature Reactor (VHTR) is passive safety. Currently all the gas cooled version of VHTR designs use Reactor Vessel Auxiliary Cooling System (RVACS) for passive decay heat removal. The decay heat first is transferred to the core barrel by conduction and radiation, and then to the reactor vessel by thermal radiation and convection; finally the decay heat is transferred to natural circulated air or water systems. RVACS can be characterized as a surface based decay heat removal system. The RVACS is especially suitable for smaller power reactors since small systems have relatively larger surface area to volume ratio. However, RVACS limits the maximum achievable power level for modular VHTRs due to the mismatch between the reactor power (proportional to volume) and decay heat removal capability (proportional to surface area). When the relative decay heat removal capability decreases, the peak fuel temperature increases, even close to the design limit. Annular core designs with inner graphite reflector can mitigate this effect; therefore can further increase the reactor power. Another way to increase the reactor power is to increase power density. However, the reactor power is also limited by the decay heat removal capability. Besides the safety considerations, VHTRs also need to be economical in order to compete with other reactor concepts and other types of energy sources. The limit of decay heat removal capability set by using RVACS has affected the economy of VHTRs. A potential alternative solution is to use a volume-based passive decay heat removal system, called Direct Reactor Auxiliary Cooling Systems (DRACS), to remove or mitigate the limitation on decay heat removal capability. DRACS composes of natural circulation loops with two sets of heat exchangers, one on the reactor side and another on the environment side. For the reactor side, cooling pipes will be inserted into holes made in the outer or

  18. Conceptual Design of Passive Safety System for Lead-Bismuth Cooled Fast Reactor

    NASA Astrophysics Data System (ADS)

    Abdullah, A. G.; Nandiyanto, A. B. D.

    2016-04-01

    This paper presents the results of the conceptual design of passive safety systems for reactor power 225 MWth using Pb-Bi coolant. Main purpose of this research is to design of heat removal system from the reactor wall. The heat from the reactor wall is removed by RVACS system using the natural circulation from the atmosphere around the reactor at steady state. The calculation is performed numerically using Newton-Raphson method. The analysis involves the heat transfer systems in a radiation, conduction and natural convection. Heat transfer calculations is performed on the elements of the reactor vessel, outer wall of guard vessel and the separator plate. The simulation results conclude that the conceptual design is able to remove heat 1.33% to 4.67% from the thermal reactor power. It’s can be hypothesized if the reactor had an accident, the system can still overcome the heat due to decay.

  19. Heat removal from high temperature tubular solid oxide fuel cells utilizing product gas from coal gasifiers.

    SciTech Connect

    Parkinson, W. J. ,

    2003-01-01

    In this work we describe the results of a computer study used to investigate the practicality of several heat exchanger configurations that could be used to extract heat from tubular solid oxide fuel cells (SOFCs) . Two SOFC feed gas compositions were used in this study. They represent product gases from two different coal gasifier designs from the Zero Emission Coal study at Los Alamos National Laboratory . Both plant designs rely on the efficient use of the heat produced by the SOFCs . Both feed streams are relatively rich in hydrogen with a very small hydrocarbon content . One feed stream has a significant carbon monoxide content with a bit less hydrogen . Since neither stream has a significant hydrocarbon content, the common use of the endothermic reforming reaction to reduce the process heat is not possible for these feed streams . The process, the method, the computer code, and the results are presented as well as a discussion of the pros and cons of each configuration for each process .

  20. Economic analysis of the integrated heating and cooling potential of a residential passive-solar water wall design

    NASA Astrophysics Data System (ADS)

    Roach, F.; Mangeng, C.; Kirschner, C.; Ben-David, S.

    Preliminary performance estimates for the heating and cooling potential of water walls were made. These estimates include the Btu displacement that is attributable to a 300-square foot water wall design in a 1200-square foot residence. The design is for a forced ventalation water wall system that includes the fans and ducting necessary to achieve a 3000-cfm flow of air. The cooling and heating energy displacement estimates are combined with appropriate region-specific fuel prices, system costs, and general economic parameters in a lifecycle cost analysis of this fixed-size water wall design. The economic indicators used to discusse the results include net present value and a total cost goal. Input data and results are presented in mapped form and used to assess the energy savings potential of the water wall in 220 regions of the continental United States.

  1. A passively-fed methanol steam reformer heated with two-stage bi-fueled catalytic combustor

    NASA Astrophysics Data System (ADS)

    Lo, Kai-Fan; Wong, Shwin-Chung

    2012-09-01

    This paper presents further progress on our simple novel passively-fed methanol steam reformer. The present study focuses on the development of a catalytic combustor workable with both hydrogen and methanol fuels. The aim is to reutilize the exhaust hydrogen from a fuel cell under stable operation but burn methanol during the start-up. On a copper plate, the catalytic combustor in a u-turn channel is integrally machined under a two-turn serpentine-channel reformer. To resolve the highly different fuel reactivities, a suitably diluted catalyst formula demonstrates uniform temperature distributions burning with either liquid methanol or an H2/CO2 mixture simulating the exhaust gas from a fuel cell. In a two-stage process, it first takes 25 min to reach 270 °C by burning methanol. After the fuel is switched to the H2/CO2 mixture, another 20 min is needed to attain an optimal steady state which yields a high methanol conversion of 95% and acceptably low CO fraction of 1.04% at a reaction temperature of 278 °C. The H2 and CO2 concentrations are 75.1% and 23.6%.

  2. Impact of Sn(S,Se) secondary phases in Cu2ZnSn(S,Se)4 solar cells: a chemical route for their selective removal and absorber surface passivation.

    PubMed

    Xie, Haibing; Sánchez, Yudania; López-Marino, Simón; Espíndola-Rodríguez, Moisés; Neuschitzer, Markus; Sylla, Diouldé; Fairbrother, Andrew; Izquierdo-Roca, Victor; Pérez-Rodríguez, Alejandro; Saucedo, Edgardo

    2014-08-13

    The control and removal of secondary phases is one of the major challenges for the development of Cu2ZnSn(S,Se)4 (CZTSSe)-based solar cells. Although etching processes have been developed for Cu(S,Se), Zn(S,Se), and CuSn(S,Se) secondary phases, so far very little attention has been given to the role of Sn(S,Se). In this paper, we report a chemical route using a yellow (NH4)2S solution to effectively remove Sn(S,Se). We found that Sn(S,Se) can form on the surface either because of stoichiometric deviation or by condensation. After etching, the efficiency of devices typically increases between 20 and 65% relative to the before etch efficiencies. We achieved a maximum 5.9% efficiency in Se-rich CZTSSe-based devices. It is confirmed that this feature is related not only to the removal of Sn(S,Se) but also to the unexpected passivation of the surface. We propose a phenomenological model for this passivation, which may open new perspectives for the development of CZTSSe-based solar cells. PMID:25033026

  3. Impact of Sn(S,Se) secondary phases in Cu2ZnSn(S,Se)4 solar cells: a chemical route for their selective removal and absorber surface passivation.

    PubMed

    Xie, Haibing; Sánchez, Yudania; López-Marino, Simón; Espíndola-Rodríguez, Moisés; Neuschitzer, Markus; Sylla, Diouldé; Fairbrother, Andrew; Izquierdo-Roca, Victor; Pérez-Rodríguez, Alejandro; Saucedo, Edgardo

    2014-08-13

    The control and removal of secondary phases is one of the major challenges for the development of Cu2ZnSn(S,Se)4 (CZTSSe)-based solar cells. Although etching processes have been developed for Cu(S,Se), Zn(S,Se), and CuSn(S,Se) secondary phases, so far very little attention has been given to the role of Sn(S,Se). In this paper, we report a chemical route using a yellow (NH4)2S solution to effectively remove Sn(S,Se). We found that Sn(S,Se) can form on the surface either because of stoichiometric deviation or by condensation. After etching, the efficiency of devices typically increases between 20 and 65% relative to the before etch efficiencies. We achieved a maximum 5.9% efficiency in Se-rich CZTSSe-based devices. It is confirmed that this feature is related not only to the removal of Sn(S,Se) but also to the unexpected passivation of the surface. We propose a phenomenological model for this passivation, which may open new perspectives for the development of CZTSSe-based solar cells.

  4. Removal of Pb(II) from water by the activated carbon modified by nitric acid under microwave heating.

    PubMed

    Yao, Shuheng; Zhang, Jiajun; Shen, Dekui; Xiao, Rui; Gu, Sai; Zhao, Ming; Liang, Junyu

    2016-02-01

    The rice husk based activated carbon (RH-AC) was treated by nitric acid under microwave heating, in order to improve its capability for the removal of heavy metal ions from water. The optimal conditions for the modification of RH-AC (M-RH-AC) were determined by means of orthogonal array experimental design, giving those as the concentration of nitric acid of 8mol/L, modification time of 15min, modification temperature of 130°C and microwave power of 800W. The characteristics of the M-RH-AC and RH-AC were examined by BET, XRD, Raman spectrum, pH titration, zeta potential, Boehm titration and FTIR analysis. The M-RH-AC has lower pore surface area, smaller crystallite, lower pHIEP and more oxygen-containing functional groups than the RH-AC. Removal capacity of Pb(II) ions by the M-RH-AC and RH-AC from water solution was estimated concerning the influence of contact time, pH value, and initial concentration. The equilibrium time of Pb(II) removal was found to be around 90min after modification process. Two kinetic models are adopted to describe the possible Pb(II) adsorption mechanism, finding that the adsorption rate of Pb(II) ions by the M-RH-AC is larger than that of RH-AC. PMID:26520818

  5. Regional relation between skin blood flow and sweating to passive heating and local administration of acetylcholine in young, healthy humans

    PubMed Central

    Kenney, W. Larry; Alexander, Lacy M.

    2013-01-01

    Regional variation in sweating over the human body is widely recognized yet variation in vasomotor responses and mechanisms causing this variation remain unclear. This study aimed to explore the relation between regional sweating rates (RSR) and skin blood flow (SkBF) responses to thermal and pharmacological stimuli in young, healthy subjects. In nine subjects (23 ± 3 yr), intradermal microdialysis (MD) probes were inserted into the ventral forearm, abdomen, thigh, and lower back and perfused with lactated Ringer solution. RSR over each MD membrane were measured using ventilated capsules with a laser Doppler probe housed in each capsule for measurement of red cell flux (laser Doppler flux, LDF) as an index of SkBF. Subjects completed a whole body heating protocol to 1°C rise in oral temperature and an acetylcholine dose response (ACh 1 × 10−7-0.1 M; mean skin temperature 34°C). Maximal LDF were obtained at the end of both protocols (50 mM sodium nitroprusside).During heating RSR varied among sites (P < 0.0001) and was greater on the back versus other sites (P < 0.05), but LDF was similar between sites (P = 0.343). RSR and SkBF showed a strong relation during initial (arm: r = 0.77 ± 0.09, thigh: r = 0.81 ± 0.08, abdomen: r = 0.89 ± 0.04, back: r = 0.86 ± 0.04) but not latter stages of heating. No differences in RSR (P = 0.160) or SkBF (LDF, P = 0.841) were observed between sites during ACh perfusion. Taken together, these data suggest that increases in SkBF are necessary to initiate and increase sweating, but further rises in RSR are not fully dependent on SkBF in a dose-response manner. Furthermore, RSR cannot be explained by cholinergic sensitivity or variation in SkBF. PMID:23389110

  6. Removal of PCDDs/DFs and dl-PCBs in MWI fly ash by heating under vacuum.

    PubMed

    Misaka, Youhei; Yamanaka, Kazushi; Takeuchi, Kazuhiko; Sawabe, Kyoichi; Shobatake, Kosuke

    2006-07-01

    Temperature dependence of PCDD/DF and dioxin-like polychlorinated biphenyl (dl-PCB) concentrations in fly ash from a municipal waste incinerator (MWI) heated under vacuum has been investigated as a function of sample temperature ranging from T(s)=425 to 800 K to find out if PCDDs/DFs in fly ash evaporate and are trapped in a liquid nitrogen-cooled trap. The results show that more than 99.98% of PCDDs/DFs in TEQ is removed from fly ash by vacuum heat treatment at T(s)>650 K for 4 h. Almost no PCDDs/DFs were detected in the liquid nitrogen-cooled trap. Homologue distributions indicate that dechlorination/hydrogenation (DCH) reactions proceed in fly ash at T(s)>450 K. Arrhenius rate parameters for the DCH reactions have been determined for each homologue assuming that only DCH reactions occur. The fly ash heated under vacuum at 650 or 800 K was reheated at 573 K (300 degrees C) in a stream of dry or humid air to see how much PCDDs/DFs and dl-PCBs are regenerated. We have found that (1) PCDDs/DFs are regenerated in both 650 K and 800 K treated fly ash, whereas dl-PCBs are regenerated in 650 K treated fly ash, (2) formation of PCDFs predominates over that of PCDDs or dl-PCBs, and (3) less chlorinated homologues are abundant for PCDDs/DFs and dl-PCBs. PMID:16384596

  7. D10 experiment: coolability of UO/sub 2/ debris in sodium with downward heat removal. [LMFBR

    SciTech Connect

    Mitchell, G.W.; Ottinger, C.A.; Meister, H.

    1984-12-01

    The LMFBR Debris Coolability Program at Sandia National Laboratories investigates the coolability of particle beds which may form following a severe accident involving core disassembly in a nuclear reactor. The D series experiments utilize fission heating of fully enriched UO/sub 2/ particles submerged in sodium to realistically simulate decay heating. The D10 experiment is the first in the series to study the effects of bottom cooling of the debris that could be provided in an actual accident condition by structural materials onto which the debris might settle. Additionally, the D10 experiment was designed to achieve maximum temperatures in the debris approaching the melting point of UO/sub 2/. The experiment was successfully operated for over 50 hours and investigated downward heat removal in a packed bed at specific powers of 0.16 to 0.58 W/g. Dryout in the debris was achieved at powers from 0.42 to 0.58 W/g. Channels were induced in the bed and channeled bed dryout was achieved at powers of 1.06 to 1.77 W/g. Maximum temperatures in excess of 2500/sup 0/C were attained.

  8. Passive heat transfer augmentation in a cylindrical annulus utilizing multiple perturbations on the inner and outer cylinders

    SciTech Connect

    Iyer, S.V.; Vafai, K.

    1999-05-14

    The study of natural convection flow and heat transfer within a cylindrical annulus has received considerable attention because of its numerous applications, such as in nuclear reactor design, electronic component cooling, thermal storage systems, energy conservation, energy storage, and energy transmission. Here, the effects of multiple geometric perturbations on the inner and outer cylinders of an annulus with impermeable end walls are investigated in this work. A three-dimensional study was done using a numerical scheme based on a Galerkin method of finite element formulation. The nature of the buoyancy-induced flow field has been analyzed in detail. The flow fields for the cases considered were found to be qualitatively similar, and the introduction of each additional perturbation altered the flow field in a regular and recurring manner. The introduction of each perturbation on the outer cylinder causes clockwise and counterclock-wise rotating patterns on either side of the perturbation in the upper circumferential regions of the annulus. The motion of the fluid entrained by these circulatory patterns constitutes the key features of the flow pattern observed in the annulus. It is observed that the presence of multiple perturbations on the inner and outer cylinders substantially increases the overall heat transfer rate as compared to the regular annulus without any perturbation. Key qualitative and quantitative effects of the introduction of perturbations on both the inner and outer cylinders of the annulus are discussed.

  9. Effectiveness of photocatalytic filter for removing volatile organic compounds in the heating, ventilation, and air conditioning system.

    PubMed

    Yu, Kuo-Pin; Lee, Grace Whei-May; Huang, Wei-Ming; Wu, Chih-Cheng; Lou, Chia-ling; Yang, Shinhao

    2006-05-01

    Nowadays, the heating, ventilation, and air conditioning (HVAC) system has been an important facility for maintaining indoor air quality. However, the primary function of typical HVAC systems is to control the temperature and humidity of the supply air. Most indoor air pollutants, such as volatile organic compounds (VOCs), cannot be removed by typical HVAC systems. Thus, some air handling units for removing VOCs should be added in typical HVAC systems. Among all of the air cleaning techniques used to remove indoor VOCs, photocatalytic oxidation is an attractive alternative technique for indoor air purification and deodorization. The objective of this research is to investigate the VOC removal efficiency of the photocatalytic filter in a HVAC system. Toluene and formaldehyde were chosen as the target pollutants. The experiments were conducted in a stainless steel chamber equipped with a simplified HVAC system. A mechanical filter coated with Degussa P25 titania photocatalyst and two commercial photocatalytic filters were used as the photocatalytic filters in this simplified HVAC system. The total air change rates were controlled at 0.5, 0.75, 1, 1.25, and 1.5 hr(-1), and the relative humidity (RH) was controlled at 30%, 50%, and 70%. The ultraviolet lamp used was a 4-W, ultraviolet-C (central wavelength at 254 nm) strip light bulb. The first-order decay constant of toluene and formaldehyde found in this study ranged from 0.381 to 1.01 hr(-1) under different total air change rates, from 0.34 to 0.433 hr(-1) under different RH, and from 0.381 to 0.433 hr(-1) for different photocatalytic filters.

  10. Enhancement of heat removal using concave liquid metal targets for high-power accelerators.

    SciTech Connect

    Konkashbaev, I.; Fischer, P.; Hassanein, A.; Mokhov, N. V.; Mathematics and Computer Science; FNAL

    2007-01-01

    The need is increasing for development of high-power targets and beam dump areas for the production of intense beams of secondary particles. The severe constraints arising from a megawatt beam deposited on targets and absorbers call for nontrivial procedures to dilute the beam. This study describes the development of targets and absorbers and the advantages of using flowing liquid metal in concave channels first proposed by IFMIF to raise the liquid metal boiling point by increasing the pressure in liquid supported by a centrifugal force. Such flow with a back-wall is subject to Taylor-Couette instability. The instability can play a positive role of increasing the heat transfer from the hottest region in the target/absorber to the back-wall cooled by water. Results of theoretical analysis and numerical modeling of both targets and dump areas for the IFMIF, ILC, and RIA facilities are presented.

  11. Thermal-hydraulic processes involved in loss of residual heat removal during reduced inventory operation. Revision 1

    SciTech Connect

    Fletcher, C.D.; McHugh, P.R.; Naff, S.A.; Johnsen, G.W.

    1991-02-01

    This paper identifies the topics needed to understand pressurized water reactor response to an extended loss of residual heat removal event during refueling and maintenance outages. By identifying the possible plant conditions and cooling methods that would be used for each cooling mode, the controlling thermal-hydraulic processes and phenomena were identified. Controlling processes and phenomena include: gravity drain, core water boil-off, and reflux cooling processes. Important subcategories of the reflux cooling processes include: the initiation of reflux cooling from various plant conditions, the effects of air on reflux cooling, core level depression effects, issues regarding the steam generator secondaries, and the special case of boiler-condenser cooling with once-through steam generators. 25 refs., 6 figs., 1 tab.

  12. Passive containment cooling system

    DOEpatents

    Conway, Lawrence E.; Stewart, William A.

    1991-01-01

    A containment cooling system utilizes a naturally induced air flow and a gravity flow of water over the containment shell which encloses a reactor core to cool reactor core decay heat in two stages. When core decay heat is greatest, the water and air flow combine to provide adequate evaporative cooling as heat from within the containment is transferred to the water flowing over the same. The water is heated by heat transfer and then evaporated and removed by the air flow. After an initial period of about three to four days when core decay heat is greatest, air flow alone is sufficient to cool the containment.

  13. Effects of differential wall heating in street canyons on dispersion and ventilation characteristics of a passive scalar

    NASA Astrophysics Data System (ADS)

    Cai, Xiaoming

    2012-05-01

    This paper presents the first large-eddy simulation (LES) study of transfer and dispersion of a scalar released from a rough urban facet, either the street surface, the upstream-wall, or the downstream-wall, under the thermo-dynamical conditions of either the upstream-wall or the downstream-wall, plus the roof, heated by solar radiation. The boundary condition of a constant value is adopted for the scalars on the rough urban facets and a wall function is proposed for the scalars. The LES results demonstrate that dispersion inside the street canyon possesses distinctive characteristics for two conditions: the assisting condition in which the thermal-driven flow has the same direction as that of the wind-driven vortex and the opposing condition in which the thermal-driven flow has the opposite direction as that of the wind-driven vortex. For the street-released scalar under the opposing condition, the concentration fluctuations relative to the mean concentration can reach 50% and in general they are much larger than those for the assisting cases which are in the range of 25-30%. The exchange velocity of a scalar between the street canyon air and the urban boundary layer (UBL), wCB(c), is one order of magnitude larger than the exchange velocity between a facet and the urban boundary layer, UBL, w0B(c), indicating quantitatively that the resistance to the transfer of a facet-released scalar is dominated by the near-facet processes. As the temperature difference between the wall and the UBL, ΔT, increases, the total resistance to street canyon ventilation becomes more dominated by the near-facet resistance. The assisting conditions are favourable to ventilating the scalars from both walls, whereas the opposing conditions are only favourable to the ventilation of the downstream-wall released scalar. In the range of ΔT tested in this study, the exchange velocity, wCB(c), linearly increases with ΔT and can be well parameterised. For the assisting cases, the advective

  14. TRANSIENT HEAT TRANSFER ANALYSIS FOR ION-EXCHANGE WASTE REMOVAL PROCESS

    SciTech Connect

    Lee, S.

    2010-07-12

    The small column ion exchange (SCIX) process treats low curie salt (LCS) waste before feeding it to the saltstone facility to be made into grout. Through this process, radioactive cesium from the salt solution is absorbed into the CST bed. A CST column loaded with radioactive cesium will generate significant heat from radiolytic decay. If engineering designs of the CST sorption column can not handle this thermal load, hot spots may develop locally within the column and degrade the performance of the ion-exchange process. The CST starts to degrade at about 80 to 85 C, and the CST completely changes to another material above 120 C. In addition, the process solution will boil around 130 C. If the column boiled dry, the sorbent could plug the column and require replacement of the column module. The objective of the present work is to compute temperature distributions across the column as a function of transit time after the initiation of accidents when there is loss of the salt solution flow in the CST column under abnormal conditions of the process operations. In this situation, the customer requested that the calculations should be conservative in that the model results would show the maximum centerline temperatures achievable by the CST design configurations. The thermal analysis results will be used to evaluate the fluid temperature distributions and the process component temperatures within the ion exchange system. This information will also assist in the system design and maintenance.

  15. Passive broadband acoustic thermometry

    NASA Astrophysics Data System (ADS)

    Anosov, A. A.; Belyaev, R. V.; Klin'shov, V. V.; Mansfel'd, A. D.; Subochev, P. V.

    2016-04-01

    The 1D internal (core) temperature profiles for the model object (plasticine) and the human hand are reconstructed using the passive acoustothermometric broadband probing data. Thermal acoustic radiation is detected by a broadband (0.8-3.5 MHz) acoustic radiometer. The temperature distribution is reconstructed using a priori information corresponding to the experimental conditions. The temperature distribution for the heated model object is assumed to be monotonic. For the hand, we assume that the temperature distribution satisfies the heat-conduction equation taking into account the blood flow. The average error of reconstruction determined for plasticine from the results of independent temperature measurements is 0.6 K for a measuring time of 25 s. The reconstructed value of the core temperature of the hand (36°C) generally corresponds to physiological data. The obtained results make it possible to use passive broadband acoustic probing for measuring the core temperatures in medical procedures associated with heating of human organism tissues.

  16. Chromatographic removal and heat inactivation of hepatitis A virus during manufacture of human albumin.

    PubMed

    Adcock, W L; MacGregor, A; Davies, J R; Hattarki, M; Anderson, D A; Goss, N H

    1998-08-01

    CSL Limited, an Australian biopharmaceutical company, has recently converted its method of manufacture for human albumin from a traditional Cohn-ethanol fractionation method to a method employing chromatographic techniques. Studies were undertaken to determine the efficiency of the chromatographic and pasteurization steps used in the manufacture of Albumex(R) (CSL's trade name for albumin) in removing and inactivating the potential viral contaminant, hepatitis A virus (HAV). The manufacturing process for Albumex(R) includes three chromatographic steps, two of which are ion-exchange steps (DEAE-Sepharose(R) Fast Flow and CM-Sepharose(R) Fast Flow) and the third is a gel-filtration step (Sephacryl(R) S200 HR). The final stage of the Albumex(R) process involves a bulk pasteurization step where product is held at 60 degrees C for 10 h. HAV partitioning experiments on the DEAE-Sepharose(R) FF and CM-Sepharose(R) FF ion-exchange and Sephacryl(R) S200 HR gel-filtration columns were performed with scaled-down models of the production-scale chromatographic Albumex(R) process. Production samples collected before each of the chromatographic steps were spiked with HAV and processed through each of the scaled-down chromatographic columns. Samples collected during processing were assayed and the log10 reduction factors calculated. Inactivation kinetics of HAV were examined during the pasteurization of Albumex(R) 5 and 20 [5% and 20% (w/v) albumin solutions] held at 60 degrees C for 10 h. Log10 reductions for HAV through the DEAE-Sepharose(R) FF, CM-Sepharose(R) FF and Sephacryl(R) S200 HR chromatographic columns were 5.3, 1.5 and 4.2 respectively, whereas a 4.4 and a greater than 3.9 log10 reduction in HAV in Albumex(R) 5 and 20 respectively were achieved during pasteurization.

  17. Safety significance of ATR (Advanced Test Reactor) passive safety response attributes

    SciTech Connect

    Atkinson, S.A.

    1989-01-01

    The Advanced Test Reactor (ATR) at the Idaho National Engineering Laboratory was designed with some passive safety response attributes which contribute to the safety posture of the facility. The three passive safety attributes being evaluated in the paper are: (1) In-core and in-vessel natural convection cooling, (2) a passive heat sink capability of the ATR primary coolant system (PCS) for the transfer of decay power from the uninsulated piping to the confinement, and (3) gravity feed of emergency coolant makeup. The safety significance of the ATR passive safety response attributes is that the reactor can passively respond for most transients, given a reactor scram, to provide adequate decay power removal and a significant time for operator action should the normal active heat removal systems and their backup systems both fail. The ATR Interim Level 1 Probabilistic Risk Assessment (PRA) model ands results were used to evaluate the significance to ATR fuel damage frequency (or probability) of the above three passive response attributes. The results of the evaluation indicate that the first attribute is a major safety characteristic of the ATR. The second attribute has a noticeable but only minor safety significance. The third attribute has no significant influence on the ATR Level 1 PRA because of the diversity and redundancy of the ATR firewater injection system (emergency coolant system). 8 refs., 4 figs., 1 tab.

  18. Hood River Passive House

    SciTech Connect

    Hales, David

    2014-01-01

    The Hood River Passive Project was developed by Root Design Build of Hood River Oregon using the Passive House Planning Package (PHPP) to meet all of the requirements for certification under the European Passive House standards. The Passive House design approach has been gaining momentum among residential designers for custom homes and BEopt modeling indicates that these designs may actually exceed the goal of the U.S. Department of Energy's (DOE) Building America program to "reduce home energy use by 30%-50% (compared to 2009 energy codes for new homes). This report documents the short term test results of the Shift House and compares the results of PHPP and BEopt modeling of the project. The design includes high R-Value assemblies, extremely tight construction, high performance doors and windows, solar thermal DHW, heat recovery ventilation, moveable external shutters and a high performance ductless mini-split heat pump. Cost analysis indicates that many of the measures implemented in this project did not meet the BA standard for cost neutrality. The ductless mini-split heat pump, lighting and advanced air leakage control were the most cost effective measures. The future challenge will be to value engineer the performance levels indicated here in modeling using production based practices at a significantly lower cost.

  19. Hood River Passive House

    SciTech Connect

    Hales, D.

    2014-01-01

    The Hood River Passive Project was developed by Root Design Build of Hood River Oregon using the Passive House Planning Package (PHPP) to meet all of the requirements for certification under the European Passive House standards. The Passive House design approach has been gaining momentum among residential designers for custom homes and BEopt modeling indicates that these designs may actually exceed the goal of the U.S. Department of Energy's (DOE) Building America program to reduce home energy use by 30%-50% (compared to 2009 energy codes for new homes). This report documents the short term test results of the Shift House and compares the results of PHPP and BEopt modeling of the project. The design includes high R-Value assemblies, extremely tight construction, high performance doors and windows, solar thermal DHW, heat recovery ventilation, moveable external shutters and a high performance ductless mini-split heat pump. Cost analysis indicates that many of the measures implemented in this project did not meet the BA standard for cost neutrality. The ductless mini-split heat pump, lighting and advanced air leakage control were the most cost effective measures. The future challenge will be to value engineer the performance levels indicated here in modeling using production based practices at a significantly lower cost.

  20. A study of the heat-removal process at the semiconductor-ceramics interface in solar cells by the laser thermal-wave method

    NASA Astrophysics Data System (ADS)

    Glazov, A. L.; Kalinovskii, V. S.; Kontrosh, E. V.; Muratikov, K. L.

    2016-06-01

    The influence of the solder layer between a semiconductor solar cell and heat-removing ceramics on the nonstationary heat-transfer processes has been investigated by the laser thermal-wave method. A theoretical model taking into account the presence of additional thermal resistance and thermal capacitance at the soldered junction is proposed. Different soldering modes are considered. It is shown that the laser thermal- wave methods within the developed model allow one to correctly estimate the thermophysical properties of multilayer structures.

  1. Passivated niobium cavities

    SciTech Connect

    Myneni, Ganapati Rao; Hjorvarsson, Bjorgvin; Ciovati, Gianluigi

    2006-12-19

    A niobium cavity exhibiting high quality factors at high gradients is provided by treating a niobium cavity through a process comprising: 1) removing surface oxides by plasma etching or a similar process; 2) removing hydrogen or other gases absorbed in the bulk niobium by high temperature treatment of the cavity under ultra high vacuum to achieve hydrogen outgassing; and 3) assuring the long term chemical stability of the niobium cavity by applying a passivating layer of a superconducting material having a superconducting transition temperature higher than niobium thereby reducing losses from electron (cooper pair) scattering in the near surface region of the interior of the niobium cavity. According to a preferred embodiment, the passivating layer comprises niobium nitride (NbN) applied by reactive sputtering.

  2. Measurement of convectional heat transfer coefficients in a primary containment vessel with outer pool

    SciTech Connect

    Fukui, Toru; Kataoka, Yoshiyuki; Hatamiya, Shigeo

    1990-01-01

    New concepts with passive safety systems that use no active compounds, such as pumps, have been recently developed for next-generation nuclear power plants. In these concepts, several ideas and their combination of passive components were adopted for emergency core cooling and residual heat removal systems. For the residual heat removal system, utilization of natural circulation heat transfer in water pools was proposed as a passive containment cooling system (PCCS), which removes decay heat from the primary containment vessel (PCV) during loss-of-coolant accidents (LOCAs). This system consists of a suppression pool (S/P) and an outer pool (O/P), which are set adjacently inside and outside of the steel PCV wall. The core decay heat during LOCA is released through a break as steam and is led into the S/P. The injected steam condenses there, resulting a pool temperature rise. The adsorbed heat in the S/P is transferred to the O/P by convection in both pools and thermal conduction through the steel PCV wall. The heat transferred to the O/P is finally released to the atmosphere by vaporization of the O/P water. Estimation of the convectional heat transfer coefficients in both pools is necessary to predict the heat removal capability in this system precisely. The heat transfer coefficients measured in this study are useful for the design of the next-generation nuclear reactor as the fundamental thermal-hydraulic data in the primary containment vessel with the outer pool.

  3. Generation of a homozygous fertilization-defective gcs1 mutant by heat-inducible removal of a rescue gene.

    PubMed

    Nagahara, Shiori; Takeuchi, Hidenori; Higashiyama, Tetsuya

    2015-03-01

    Key message: New gametic homozygous mutants. In angiosperms, a haploid male gamete (sperm cell) fuses with a haploid female gamete (egg cell) during fertilization to form a zygote carrying paternally and maternally derived chromosomes. Several fertilization-defective mutants in Arabidopsis thaliana, including a generative cell-specific 1 (gcs1)/hapless 2 mutant, the sperm cells of which are unable to fuse with female gametes, can only be maintained as heterozygous lines due to the infertile male or female gametes. Here, we report successful generation of a gcs1 homozygous mutant by heat-inducible removal of the GCS1 transgene. Using the gcs1 homozygous mutant as male, the defect in gamete fusion was observed with great frequency; in our direct observation by semi-in vivo fertilization assay using ovules, 100 % of discharged sperm cells in culture failed to show gamete fusion. More than 70 % of ovules in the pistil received a second pollen tube as attempted fertilization recovery. Moreover, gcs1 mutant sperm cells could fertilize female gametes at a low frequency in the pistil. This strategy to generate homozygous fertilization-defective mutants will facilitate novel approaches in plant reproduction research.

  4. Theoretical Design of a Thermosyphon for Efficient Process Heat Removal from Next Generation Nuclear Plant (NGNP) for Production of Hydrogen

    SciTech Connect

    Piyush Sabharwall; Fred Gunnerson; Akira Tokuhiro; Vivek Utgiker; Kevan Weaver; Steven Sherman

    2007-10-01

    The work reported here is the preliminary analysis of two-phase Thermosyphon heat transfer performance with various alkali metals. Thermosyphon is a device for transporting heat from one point to another with quite extraordinary properties. Heat transport occurs via evaporation and condensation, and the heat transport fluid is re-circulated by gravitational force. With this mode of heat transfer, the thermosyphon has the capability to transport heat at high rates over appreciable distances, virtually isothermally and without any requirement for external pumping devices. For process heat, intermediate heat exchangers (IHX) are required to transfer heat from the NGNP to the hydrogen plant in the most efficient way possible. The production of power at higher efficiency using Brayton Cycle, and hydrogen production requires both heat at higher temperatures (up to 1000oC) and high effectiveness compact heat exchangers to transfer heat to either the power or process cycle. The purpose for selecting a compact heat exchanger is to maximize the heat transfer surface area per volume of heat exchanger; this has the benefit of reducing heat exchanger size and heat losses. The IHX design requirements are governed by the allowable temperature drop between the outlet of the NGNP (900oC, based on the current capabilities of NGNP), and the temperatures in the hydrogen production plant. Spiral Heat Exchangers (SHE’s) have superior heat transfer characteristics, and are less susceptible to fouling. Further, heat losses to surroundings are minimized because of its compact configuration. SHEs have never been examined for phase-change heat transfer applications. The research presented provides useful information for thermosyphon design and Spiral Heat Exchanger.

  5. Simulation of decay heat removal by natural convection in a pool type fast reactor model-ramona-with coupled 1D/2D thermal hydraulic code system

    SciTech Connect

    Kasinathan, N.; Rajakumar, A.; Vaidyanathan, G.; Chetal, S.C.

    1995-09-01

    Post shutdown decay heat removal is an important safety requirement in any nuclear system. In order to improve the reliability of this function, Liquid metal (sodium) cooled fast breeder reactors (LMFBR) are equipped with redundant hot pool dipped immersion coolers connected to natural draught air cooled heat exchangers through intermediate sodium circuits. During decay heat removal, flow through the core, immersion cooler primary side and in the intermediate sodium circuits are also through natural convection. In order to establish the viability and validate computer codes used in making predictions, a 1:20 scale experimental model called RAMONA with water as coolant has been built and experimental simulation of decay heat removal situation has been performed at KfK Karlsruhe. Results of two such experiments have been compiled and published as benchmarks. This paper brings out the results of the numerical simulation of one of the benchmark case through a 1D/2D coupled code system, DHDYN-1D/THYC-2D and the salient features of the comparisons. Brief description of the formulations of the codes are also included.

  6. Surfactants for Bubble Removal against Buoyancy.

    PubMed

    Raza, Md Qaisar; Kumar, Nirbhay; Raj, Rishi

    2016-01-01

    The common phenomenon of buoyancy-induced vapor bubble lift-off from a heated surface is of importance to many areas of science and technology. In the absence of buoyancy in zero gravity of space, non-departing bubbles coalesce to form a big dry patch on the heated surface and heat transfer deteriorates despite the high latent heat of vaporization of water. The situation is worse on an inverted heater in earth gravity where both buoyancy and surface tension act upwards to oppose bubble removal. Here we report a robust passive technique which uses surfactants found in common soaps and detergents to avoid coalescence and remove bubbles downwards, away from an inverted heater. A force balance model is developed to demonstrate that the force of repulsion resulting from the interaction of surfactants adsorbed at the neighboring liquid-vapor interfaces of the thin liquid film contained between bubbles is strong enough to overcome buoyancy and surface tension. Bubble removal frequencies in excess of ten Hz resulted in more than twofold enhancement in heat transfer in comparison to pure water. We believe that this novel bubble removal mechanism opens up opportunities for designing boiling-based systems for space applications. PMID:26743179

  7. Surfactants for Bubble Removal against Buoyancy

    PubMed Central

    Raza, Md. Qaisar; Kumar, Nirbhay; Raj, Rishi

    2016-01-01

    The common phenomenon of buoyancy-induced vapor bubble lift-off from a heated surface is of importance to many areas of science and technology. In the absence of buoyancy in zero gravity of space, non-departing bubbles coalesce to form a big dry patch on the heated surface and heat transfer deteriorates despite the high latent heat of vaporization of water. The situation is worse on an inverted heater in earth gravity where both buoyancy and surface tension act upwards to oppose bubble removal. Here we report a robust passive technique which uses surfactants found in common soaps and detergents to avoid coalescence and remove bubbles downwards, away from an inverted heater. A force balance model is developed to demonstrate that the force of repulsion resulting from the interaction of surfactants adsorbed at the neighboring liquid-vapor interfaces of the thin liquid film contained between bubbles is strong enough to overcome buoyancy and surface tension. Bubble removal frequencies in excess of ten Hz resulted in more than twofold enhancement in heat transfer in comparison to pure water. We believe that this novel bubble removal mechanism opens up opportunities for designing boiling-based systems for space applications. PMID:26743179

  8. Surfactants for Bubble Removal against Buoyancy

    NASA Astrophysics Data System (ADS)

    Raza, Md. Qaisar; Kumar, Nirbhay; Raj, Rishi

    2016-01-01

    The common phenomenon of buoyancy-induced vapor bubble lift-off from a heated surface is of importance to many areas of science and technology. In the absence of buoyancy in zero gravity of space, non-departing bubbles coalesce to form a big dry patch on the heated surface and heat transfer deteriorates despite the high latent heat of vaporization of water. The situation is worse on an inverted heater in earth gravity where both buoyancy and surface tension act upwards to oppose bubble removal. Here we report a robust passive technique which uses surfactants found in common soaps and detergents to avoid coalescence and remove bubbles downwards, away from an inverted heater. A force balance model is developed to demonstrate that the force of repulsion resulting from the interaction of surfactants adsorbed at the neighboring liquid-vapor interfaces of the thin liquid film contained between bubbles is strong enough to overcome buoyancy and surface tension. Bubble removal frequencies in excess of ten Hz resulted in more than twofold enhancement in heat transfer in comparison to pure water. We believe that this novel bubble removal mechanism opens up opportunities for designing boiling-based systems for space applications.

  9. Passive Accelerometer

    NASA Technical Reports Server (NTRS)

    Naumann, Robert J.; Baugher, Charles; Alexander, Iwan

    1992-01-01

    Motion of ball in liquid indicates acceleration. Passive accelerometer measures small accelerations along cylindrical axis. Principle of operation based on Stokes' law. Provides accurate measurements of small quasi-steady accelerations. Additional advantage, automatically integrates out unwanted higher-frequency components of acceleration.

  10. Multiple pollutant removal using the condensing heat exchanger: Phase 1 final report, November 1995--June 1997. Addendum 2: Task 3 topical report -- Long term wear test

    SciTech Connect

    Kudlac, G.A.

    1998-06-01

    Long-term operation of a condensing heat exchanger under typical coal-fired flue gas conditions was investigated in Phase 1, Task 3 of the Multiple Pollutant Removal Using the Condensing Heat Exchanger test program. The specific goal of this task was to determine the amount of wear, if any, on the Teflon{reg_sign}-covered heat transfer tubes in a condensing heat exchanger. A pilot-scale single-stage condensing heat exchanger (CHX{reg_sign}) was operated under typical coal-fired flue gas conditions on a continuous basis for a period of approximately 10 months. Operating conditions and particulate loadings for the test unit were monitored, Teflon{reg_sign} film thickness measurements were conducted, and surface replications (which duplicate the surface finish at the microscopic level) were taken at various times during the test. Data from the test indicate that virtually no decrease in Teflon{reg_sign} thickness was observed for the coating on the first two rows of heat exchanger tubes, even at high inlet particulate loadings (400 mg/dscm [0.35 lb/10{sup 6} Btu]). Evidence of wear was present only at the microscopic level, and even then was very minor in severity. Operation at high inlet particulate loadings resulted in accumulated ash deposits within the heat exchanger. Installation of a modified (higher flow rate) wash nozzle manifold substantially reduced subsequent deposit formation.

  11. Preservation of FFTF Data Related to Passive Safety Testing

    SciTech Connect

    Wootan, David W.; Butner, R. Scott; Omberg, Ronald P.; Makenas, Bruce J.; Nielsen, Deborah L.

    2010-10-01

    One of the goals of the Fuel Cycle Research and Development Program (FCRD) is to preserve the knowledge that has been gained in the United States on Liquid Metal Reactors (LMR). A key area deserving special attention for preservation is the data relating to passive safety testing that was conducted in FFTF and EBR-II during the 1980’s. Accidents at Unit 4 of the Chernobyl Station and Unit 2 at Three Mile Island changed the safety paradigm of the nuclear power industry. New emphasis was placed on assured safety based on intrinsic plant characteristics that protect not only the public, but the significant investment in the plant as well. Plants designated to perform in this manner are considered to be passively safe since no active sensor/alarm system or human intervention is required to bring the reactor to a safe shutdown condition. The liquid metal reactor (LMR) has several key characteristics needed for a passively safe reactor: reactor coolant with superior heat transfer capability and very high boiling point, low (atmospheric) system pressures, and reliable negative reactivity feedback. The credibility of the design for a passively safe LMR rests on two issues: the validity of analytic methods used to predict passive safety performance and the availability of relevant test data to calibrate design tools. Safety analysis methods used to analyze LMRs under the old safety paradigm were focused on calculating the source term for the Core Disruptive Accident. Passive safety design requires refined analysis methods for transient events because treatment of the detailed reactivity feedbacks is important in predicting the response of the reactor. Similarly, analytic tools should be calibrated against actual test experience in existing LMR facilities. The principal objectives of the combined FFTF natural circulation and Passive Safety Testing program were: 1) to verify natural circulation as a reliable means to safely remove decay heat, 2) to extend passive safety

  12. Passive air cooling of liquid metal-cooled reactor with double vessel leak accommodation capability

    DOEpatents

    Hunsbedt, A.; Boardman, C.E.

    1995-04-11

    A passive and inherent shutdown heat removal method with a backup air flow path which allows decay heat removal following a postulated double vessel leak event in a liquid metal-cooled nuclear reactor is disclosed. The improved reactor design incorporates the following features: (1) isolation capability of the reactor cavity environment in the event that simultaneous leaks develop in both the reactor and containment vessels; (2) a reactor silo liner tank which insulates the concrete silo from the leaked sodium, thereby preserving the silo`s structural integrity; and (3) a second, independent air cooling flow path via tubes submerged in the leaked sodium which will maintain shutdown heat removal after the normal flow path has been isolated. 5 figures.

  13. Passive air cooling of liquid metal-cooled reactor with double vessel leak accommodation capability

    DOEpatents

    Hunsbedt, Anstein; Boardman, Charles E.

    1995-01-01

    A passive and inherent shutdown heat removal method with a backup air flow path which allows decay heat removal following a postulated double vessel leak event in a liquid metal-cooled nuclear reactor. The improved reactor design incorporates the following features: (1) isolation capability of the reactor cavity environment in the event that simultaneous leaks develop in both the reactor and containment vessels; (2) a reactor silo liner tank which insulates the concrete silo from the leaked sodium, thereby preserving the silo's structural integrity; and (3) a second, independent air cooling flow path via tubes submerged in the leaked sodium which will maintain shutdown heat removal after the normal flow path has been isolated.

  14. Gas-Cooled Fast Breeder Reactor Preliminary Safety Information Document, Amendment 10. GCFR residual heat removal system criteria, design, and performance

    SciTech Connect

    Not Available

    1980-09-01

    This report presents a comprehensive set of safety design bases to support the conceptual design of the gas-cooled fast breeder reactor (GCFR) residual heat removal (RHR) systems. The report is structured to enable the Nuclear Regulatory Commission (NRC) to review and comment in the licensability of these design bases. This report also presents information concerning a specific plant design and its performance as an auxiliary part to assist the NRC in evaluating the safety design bases.

  15. Evaluation of catalyzed and electrically heated filters for removal of particulate emissions from diesel-A- and JP-8-fueled engines.

    PubMed

    Kelly, Kerry E; Wagner, David A; Lighty, JoAnn S; Sarofim, Adel F; Bretecher, Brad; Holden, Bruce; Helgeson, Norm; Sahay, Keshav; Nardi, Zack

    2004-01-01

    In-service diesel engines are a significant source of particulate matter (PM) emissions, and they have been subjected to increasingly strict emissions standards. Consequently, the wide-scale use of some type of particulate filter is expected. This study evaluated the effect of an Engelhard catalyzed soot filter (CSF) and a Rypos electrically heated soot filter on the emissions from in-service diesel engines in terms of PM mass, black carbon concentration, particle-bound polycyclic aromatic hydrocarbon concentration, and size distribution. Both filters capture PM. The CSF relies on the engine's exhaust to reach the catalyst regeneration temperature and oxidize soot, whereas the electrically heated filter contains a heating element to oxidize soot. The filters were installed on several military diesel engines. Particle concentrations and compositions were measured before and after installation of the filter and again after several months of operation. Generally, the CSF removed at least 90% of total PM, and the removal efficiency improved or remained constant after several months of operation. In contrast, the electrical filters removed 44-69% of PM mass. In addition to evaluating the soot filters, the sampling team also compared the results of several real-time particle measurement instruments to traditional filter measurements of total mass.

  16. [Passive smoking].

    PubMed

    Grandjean, E; Weber, A; Fischer, T

    1979-03-01

    Passive smoking is the involuntary inspiration of smoky indoor air. Based on the information available today, it may be assumed that passive smoking normally is no health hazard as far as the classical smoker's diseases (lung cancer, myocardial infarct, etc.) are concerned. Nevertheless, it is probable that irritations caused by tobacco smoke have an unfavorable influence on the health of small children and that of already sick persons. The main problem of passive smoking is annoyance due to odor and irritations of eyes and respiratory organs. Our investigations in a climatic chamber with healthy subjects show that air pollution caused by tobacco smoke as indicated by 5 ppm CO leads to marked eye irritations--objectively as well as subjectively--in 15 to 20% of the subjects. This corresponds to smoking 10 cigarettes per hour in a small room with an air ventilation rate of four times per hour. If air pollution caused by tobacco smoke lies below the level of 2 ppm CO, irritations and annoyance for healthy persons are regarded as low and tolerable. This corresponds to about four cigarettes per hour under the same circumstances.

  17. Off-peak power use in passive solar homes: Performance, monitoring, and analysis of periodic heating and cooling in high mass homes

    NASA Astrophysics Data System (ADS)

    Peck, J. F.

    1981-08-01

    The thermal performance of two passive solar homes and an identical standard home used as a control are described. The peak hour electrical demand rates of these homes are compared and off peak refrigeration of homes with large quantities of thermal mass is discussed. A computer model which is being developed to assess the potential of off peak refrigeration is also described.

  18. Natural Circulation in the Blanket Heat Removal System During a Loss-of-Pumping Accident (LOFA) Based on Initial Conceptual Design

    SciTech Connect

    Hamm, L.L.

    1998-10-07

    A transient natural convection model of the APT blanket primary heat removal (HR) system was developed to demonstrate that the blanket could be cooled for a sufficient period of time for long term cooling to be established following a loss-of-flow accident (LOFA). The particular case of interest in this report is a complete loss-of-pumping accident. For the accident scenario in which pumps are lost in both the target and blanket HR systems, natural convection provides effective cooling of the blanket for approximately 68 hours, and, if only the blanket HR systems are involved, natural convection is effective for approximately 210 hours. The heat sink for both of these accident scenarios is the assumed stagnant fluid and metal on the secondary sides of the heat exchangers.

  19. Heat generated by Er:YAG laser in the pulp chamber of teeth submitted to removal of dental tissue and composite resin

    NASA Astrophysics Data System (ADS)

    Zanin, Fatima; Brugnera, Aldo, Jr.; Pecora, Jesus D.; Pinheiro, Antonio; Spano, Julio; Barbin, Eduardo; Marchesan, Melissa A.

    2004-05-01

    The knowledge about and control of thermal energy produced by Er:YAG laser after irradiating hard dental tissues and compound resin is important because the pulp, like all vital biological tissue, has a certain capacity for supporting stimulus. The objective of this study was to analyze the thermal variation generated by Er:YAG laser (λ=2.94μm) during the preparation of a Class I cavity in the dental structure and in the removal of microhybrid Z100 (3M) compound resin. An evaluation was made of 30 maxillary human pre-molar teeth from the bank of the Endodontic Laboratory Center of Ribeirao Preto Dental School, Brasil. The sample was divided into 6 groups of 5 teeth each: Group 1, preparation of Class I cavity with Er:YAG laser (350mJ, 3Hz, 343 impulses, 120J, 113 seconds); Group 2, preparation of Class I cavity with Er:YAG laser (350mJ, 4Hz, 343 impulses, 120J, 81 seconds); Group 3, preparation of Class I cavity with Er:YAG laser (350mJ, 6Hz, 343 impulses, 120J, 58 seconds); Group 4, removal of compound resin from Class I preparation with Er:YAG laser (350mJ, 3Hz, 258 impulses, 90J, 85 seconds); Group 5, removal of compound resin from Class I preparation with Er:YAG laser (350mJ, 4Hz, 258 impulses, 90J, 67 seconds); Group 6, removal of compound resin from Class I preparation with Er:YAG laser (350mJ, 6Hz, 258 impulses, 42 seconds). The laser used was KaVo Key 2 (Biberach, Germany), λ=2,94μm, P=3 Watts, pulse duration of 250μs, with air-water cooling. The increase in temperature during dental preparation and the removal of the compound resin was evaluated by means of a Tektronix DMM916 Thermocouple (Consitec, Brasil). The results showed that the application of laser for the removal of the hard dental tissues and for the removal of compound resins with the pulse frequencies 3, 4 and 6 Hz did not generate heating greater than 3.1°C and remained within the histopathological limits permitted for pulp tissue (5.5°C) and there was a significant statistical

  20. Studies of Forced-Convection Heat Transfer Augmentation in Large Containment Enclosures

    SciTech Connect

    Kuhn, S.Z.; Peterson, P.F.

    2001-06-17

    Heat transfer enhancement due to jet mixing inside a cylindrical enclosure is discussed. This work addresses conservative heat transfer assumptions regarding mixing and condensation that have typically been incorporated into passive containment design analyses. This research presents the possibility for increasing decay heat removal of passive containment systems under combined natural and forced convection. Eliminating these conservative assumptions could result in a changed containment design and reduce the construction cost. It is found that the ratio of forced- and free-convection Nusselt numbers can be predicted as a function of the Archimedes number and a correlated factor accounting for jet orientation and enclosure geometry.

  1. Monitored passive-solar buildings

    NASA Astrophysics Data System (ADS)

    Jones, R. W.

    1982-06-01

    Selected performance results from six monitored passive and hybrid solar heated buildings are presented. These employ: a two story trombe wall; a thermosyphoning solar air heater with rock bin storage; a greenhouse; a composite concrete and water trombe wall; two story sunspace; and, for a mobile/modular home, direct gain and roof pond.

  2. Passive solar technology aids biogas digesters

    SciTech Connect

    Not Available

    1988-07-01

    Farming communities throughout China rely on biogas generators as a primary source of light and heat, as well as using the sludge as a nitrogen-rich fertilizer. Now researchers at Beijing's Solar Energy Laboratory have improved efficiency by building a rectangular tank out of concrete slabs, with one slanted surface painted black and covered with glass. According to a report in New Scientist, this passive solar panel generates heat in the same way as a greenhouse, raising inside temperatures by 10{degree}C and increasing biogas production by 50%. Another advantage of the new tanks is easy access, since the tank's lid sites in wells of water which form a seal against oxygen. (Old biogas tanks were made of soil, sand and a little concrete, prone to developing severe cracks which would allow oxygen to enter thus slowing down anaerobic reaction). Explains Debora MacKenzie of New Scientist: with the new tank, the farmer can simply remove the lid and attack the contents with a spade. This means that the mixture can comprise more than 10% solids. Greater density allows smaller tanks. Rural families need one cubic meter of biogas daily for light and heat; instead of the former 8 cm biogas generator, the new tanks need only be 1 cm. The prediction is that the smaller size could make biogas more popular in China's crowded towns. The biogas department is headed by He Shao Qi, who is also investigating ways to reduce production costs for the tanks.

  3. Passive environmental temperature control system

    DOEpatents

    Corliss, John M.; Stickford, George H.

    1981-01-01

    Passive environmental heating and cooling systems are described, which utilize heat pipes to transmit heat to or from a thermal reservoir. In a solar heating system, a heat pipe is utilized to carry heat from a solar heat absorber plate that receives sunlight, through a thermal insulation barrier, to a heat storage wall, with the outer end of the pipe which is in contact with the solar absorber being lower than the inner end. The inclining of the heat pipe assures that the portion of working fluid, such as Freon, which is in a liquid phase will fall by gravity to the outer end of the pipe, thereby assuring diode action that prevents the reverse transfer of heat from the reservoir to the outside on cool nights. In a cooling system, the outer end of the pipe which connects to a heat dissipator, is higher than the inner end that is coupled to a cold reservoir, to allow heat transfer only out of the reservoir to the heat dissipator, and not in the reverse direction.

  4. Tests of a protective shell passive release mechanism for hypersonic wind-tunnel models

    NASA Technical Reports Server (NTRS)

    Puster, R. L.; Dunn, J. E.

    1979-01-01

    A protective shell mechanism for wind tunnel models was developed and tested. The mechanism is passive in operation, reliable, and imposes no new structural design changes for wind tunnel models. Methods of predicting the release time and the measured loads associated with the release of the shell are given. The mechanism was tested in a series of wind tunnel tests to validate the removal process and measure the pressure loads on the model. The protective shell can be used for wind tunnel models that require a step input of heating and loading such as a thin skin heat transfer model. The mechanism may have other potential applications.

  5. Corrosive resistant heat exchanger

    DOEpatents

    Richlen, Scott L.

    1989-01-01

    A corrosive and errosive resistant heat exchanger which recovers heat from a contaminated heat stream. The heat exchanger utilizes a boundary layer of innocuous gas, which is continuously replenished, to protect the heat exchanger surface from the hot contaminated gas. The innocuous gas is conveyed through ducts or perforations in the heat exchanger wall. Heat from the heat stream is transferred by radiation to the heat exchanger wall. Heat is removed from the outer heat exchanger wall by a heat recovery medium.

  6. Enhancement of n-butanol production by in situ butanol removal using permeating-heating-gas stripping in acetone-butanol-ethanol fermentation.

    PubMed

    Chen, Yong; Ren, Hengfei; Liu, Dong; Zhao, Ting; Shi, Xinchi; Cheng, Hao; Zhao, Nan; Li, Zhenjian; Li, Bingbing; Niu, Huanqing; Zhuang, Wei; Xie, Jingjing; Chen, Xiaochun; Wu, Jinglan; Ying, Hanjie

    2014-07-01

    Butanol recovery from acetone-butanol-ethanol (ABE) fed-batch fermentation using permeating-heating-gas was determined in this study. Fermentation was performed with Clostridium acetobutylicum B3 in a fibrous bed bioreactor and permeating-heating-gas stripping was used to eliminate substrate and product inhibition, which normally restrict ABE production and sugar utilization to below 20 g/L and 60 g/L, respectively. In batch fermentation (without permeating-heating-gas stripping), C. acetobutylicum B3 utilized 60 g/L glucose and produced 19.9 g/L ABE and 12 g/L butanol, while in the integrated process 290 g/L glucose was utilized and 106.27 g/L ABE and 66.09 g/L butanol were produced. The intermittent gas stripping process generated a highly concentrated condensate containing approximately 15% (w/v) butanol, 4% (w/v) acetone, a small amount of ethanol (<1%), and almost no acids, resulting in a highly concentrated butanol solution [∼ 70% (w/v)] after phase separation. Butanol removal by permeating-heating-gas stripping has potential for commercial ABE production.

  7. Heating with waste heat

    SciTech Connect

    Beabout, R.W.

    1986-09-02

    Most of the power consumed in the gaseous diffusion process is converted into heat of compression, which is removed from the process gas and rejected into the atmosphere by recirculating cooling water over cooling towers. The water being handled through the X-333 and X-330 Process Buildings can be heated to 140 to 150/sup 0/F for heating use. The Gas Centrifuge Enrichment Plant is provided with a recirculating heating water (RHW) system which uses X-330 water and wasted heat. The RHW flow is diagrammed. (DLC)

  8. New England style passive solar

    SciTech Connect

    Kriescher, P.

    2000-06-01

    There are homeowners throughout New England who planned for and built homes that allow them to avoid the sting of winter's high heating bills. These climate-responsive homes rely on passive solar heating, cooling and lighting. An example of such a climate-responsive/passive solar house is the home that Arthur and Terry Becker build on 6 beautiful acres (2.4 hectares) of rolling farm and woodland southeast of Andover, Connecticut, in 1981. They worked very closely with their designer, Al Eggan of K.T. Lear and Associates, to ensure that they would never have to pay for home heating oil, and that they would enjoy a level of year-round comfort that they had not experienced in conventionally built homes.

  9. Gibbs free energy assisted passivation layers

    NASA Astrophysics Data System (ADS)

    Salihoglu, Omer; Tansel, T.; Hostut, M.; Ergun, Y.; Aydinli, A.

    2016-05-01

    Reduction of surface leakage is a major challenge in most photodetectors that requires the elimination of surface oxides on etched mesas during passivation. Engineering the passivation requires close attention to chemical reactions that take place at the interface during the process. In particular, removal of surface oxides may be controlled via Gibbs reactivity. We have compared electrical performance of type-II superlattice photodetectors, designed for MWIR operation, passivated by different passivation techniques. We have used ALD deposited Al2O3, HfO2, TiO2, ZnO, PECVD deposited SiO2, Si3N4 and sulphur containing octadecanethiol (ODT) selfassembled monolayers (SAM) passivation layers on InAs/GaSb p-i-n superlattice photodetectors with cutoff wavelength at 5.1 μm. In this work, we have compared the result of different passivation techniques which are done under same conditions, same epitaxial structure and same fabrication processes. We have found that ALD deposited passivation is directly related to the Gibbs free energy of the passivation material. Gibbs free energies of the passivation layer can directly be compared with native surface oxides to check the effectiveness of the passivation layer before the experimental study.

  10. Experimental study on the operational and the cooling performance of the APR+ passive auxiliary feedwater system

    SciTech Connect

    Kang, K. H.; Bae, B. U.; Kim, S.; Cho, Y. J.; Park, Y. S.; Kim, B. D.

    2012-07-01

    The passive auxiliary feedwater system (PAFS) is one of the advanced safety features adopted in the APR+ which is intended to completely replace the conventional active auxiliary feedwater system. The PAFS cools down the steam generator secondary side and eventually removes the decay heat from the reactor core by introducing a natural driving force mechanism; i.e., condensing steam in nearly-horizontal U-tubes submerged inside the passive condensation cooling tank (PCCT). With an aim of validating the cooling and operational performance of the PAFS, the separate effect test, PASCAL (PAFS Condensing Heat Removal Assessment Loop), is being performed to experimentally investigate the condensation heat transfer and natural convection phenomena in the PAFS. A single nearly-horizontal U-tube whose dimension is same as the prototypic U-tube of the APR+ PAFS is simulated in the PASCAL test. By performing the PASCAL test, the major thermal-hydraulic parameters such as local/overall heat transfer coefficients, fluid temperature inside the tube, wall temperature of the tube, and pool temperature distribution in the PCCT were produced not only to evaluate the current condensation heat transfer model but also to present database for the safety analysis related with the PAFS. (authors)

  11. Passivation of fluorinated activated charcoal

    SciTech Connect

    Del Cul, G.D.; Trowbridge, L.D.; Simmons, D.W.; Williams, D.F.; Toth, L.M.

    1997-10-01

    The Molten Salt Reactor Experiment (MSRE), at the Oak Ridge National Laboratory has been shut down since 1969 when the fuel salt was drained from the core into two Hastelloy N tanks at the reactor site. In 1995, a multiyear project was launched to remediate the potentially hazardous conditions generated by the movement of fissile material and reactive gases from the storage tanks into the piping system and an auxiliary charcoal bed (ACB). The top 12 in. of the ACB is known by gamma scan and thermal analysis to contain about 2.6 kg U-233. According to the laboratory tests, a few feet of fluorinated charcoal are believed to extend beyond the uranium front. The remainder of the ACB should consist of unreacted charcoal. Fluorinated charcoal, when subjected to rapid heating, can decompose generating gaseous products. Under confined conditions, the sudden exothermic decomposition can produce high temperatures and pressures of near-explosive characteristics. Since it will be necessary to drill and tap the ACB to allow installation of piping and instrumentation for remediation and recovery activities, it is necessary to chemically convert the reactive fluorinated charcoal into a more stable material. Ammonia can be administered to the ACB as a volatile denaturing agent that results in the conversion of the C{sub x}F to carbon and ammonium fluoride, NH{sub 4}F. The charcoal laden with NH{sub 4}F can then be heated without risking any sudden decomposition. The only consequence of heating the treated material will be the volatilization of NH{sub 4}F as a mixture of NH{sub 3} and HF, which would primarily recombine as NH{sub 4}F on surfaces below 200 C. The planned scheme for the ACB denaturing is to flow diluted ammonia gas in steps of increasing NH{sub 3} concentration, 2% to 50%, followed by the injection of pure ammonia. This report summarizes the planned passivation treatment scheme to stabilize the ACB and remove the potential hazards. It also includes basic information

  12. Assessment of residential passive solar/gas-fired energy systems

    NASA Astrophysics Data System (ADS)

    Hartman, D. L.; Hirshberg, A. S.

    1982-12-01

    The study was made to provide a comprehensive analysis of the issues involved in integrating passive solar with gas-fired back-up energy systems including: characterize major passive solar technologies; analyze technical and economic requirements of back-up heating and cooling systems; evaluate potential improvements for gas-fired heating equipment that could enhance its fit with passive solar heating; investigate the feasibility of passive solar cooling coupled with gas dehumidification equipment; and identify R&D opportunities for GRI which offer benefits to the gas ratepayer and to the gas industry. Passive solar heating, because of its potential to significantly reduce home heating loads and of the ease with which electric backup systems can be installed could result in a decrease in gas market share, as a primary heating fuel in new housing.

  13. The effects of urea modification and heat treatment on the process of NO2 removal by wood-based activated carbon.

    PubMed

    Bashkova, Svetlana; Bandosz, Teresa J

    2009-05-01

    The removal of NO(2) on urea-modified and heat-treated wood-based activated carbons was studied. From the obtained results it was found that these modifications, especially when done at 950 degrees C, have a positive effect on NO(2) adsorption and on the retention of NO (the product of NO(2) reduction by carbon). The presence of moisture in the system enhances the removal of NO(2) but negatively affects the retention of NO. It is possible that the formation of active centers on the carbon surface and some increase in the volume of supermicropores during the high temperature treatment play a significant role in these removal processes. The surface of the carbons was analyzed in terms of the pK(a) distributions. The qualitative and quantitative analyses of the NO(2) adsorption products were carried out by means of FTIR and TA techniques, respectively. The main products found on the carbon surface were the NO(3) and NO(2) species.

  14. Lotus-like effect for metal filings recovery and particle removal on heated metal surfaces using Leidenfrost water droplets.

    PubMed

    Tan, Cher Lin Clara; Sapiha, Kostantyn; Leong, Yoke Fun Hannah; Choi, Siwon; Anariba, Franklin; Thio, Beng Joo Reginald

    2015-07-21

    A "lotus-like" effect is applied to demonstrate the ability of the Leidenfrost water droplets to recover Cu particles on a heated Al substrate. Cu particles on the heated surface adhere to the rim of the Leidenfrost droplets and eventually coat the droplets' surface to form an aggregation. When Fe filings are added to the Cu particles, the aggregated mixture can then be collected using a strong rare earth magnet (NdFeB) upon evaporation of the water. We also show that the Leidenfrost effect can be effectively utilized to recover both hydrophobic (dust and activated carbon) and hydrophilic (SiO2 and MgO) particles from heated Al surfaces without any topographical modification or surfactant addition. Our results show that hydrophobic and hydrophilic materials can be collected with >92% and >96% effectiveness on grooved and smooth Al surfaces, respectively. Furthermore, we observed no significant differences in the amount of material collected above the Leidenfrost point within the tested temperature range (240 °C vs. 340 °C) as well as when the Al sheet was replaced with a Cu sheet as the substrate. However, we did observe that the Leidenfrost droplets were able to collect a greater amount of material when the working liquid was water than when it was ethanol. Our findings show promise in the development of an effective precious coinage metal filings recovery technology for application in the mint industry, as well as the self-cleaning of metallic and semiconductor surfaces where manual cleaning is not amenable. PMID:26053932

  15. Thermal-hydraulic simulation of natural convection decay heat removal in the High Flux Isotope Reactor using RELAP5 and TEMPEST: Part 1, Models and simulation results

    SciTech Connect

    Morris, D.G.; Wendel, M.W.; Chen, N.C.J.; Ruggles, A.E.; Cook, D.H.

    1989-01-01

    A study was conducted to examine decay heat removal requirements in the High Flux Isotope Reactor (HFIR) following shutdown from 85 MW. The objective of the study was to determine when forced flow through the core could be terminated without causing the fuel to melt. This question is particularly relevant when a station blackout caused by an external event is considered. Analysis of natural circulation in the core, vessel upper plenum, and reactor pool indicates that 12 h of forced flow will permit a safe shutdown with some margin. However, uncertainties in the analysis preclude conclusive proof that 12 h is sufficient. As a result of the study, two seismically qualified diesel generators were installed in HFIR. 9 refs., 4 figs.

  16. Fundamental studies of passivity and passivity breakdown

    SciTech Connect

    Macdonald, D.D.; Urquidi-Macdonald, M.; Song, H.; Biaggio-Rocha, S.; Searson, P.

    1991-11-01

    This report summarizes the findings of our fundamental research program on passivity and passivity breakdown. During the past three and one half years in this program (including the three year incrementally-funded grant prior to the present grant), we developed and experimentally tested various physical models for the growth and breakdown of passive films on metal surfaces. These models belong to a general class termed point defects models'' (PDMs), in which the growth and breakdown of passive films are described in terms of the movement of anion and cation vacancies.

  17. Bismuth Passivation Technique for High-Resolution X-Ray Detectors

    NASA Technical Reports Server (NTRS)

    Chervenak, James; Hess, Larry

    2013-01-01

    The Athena-plus team requires X-ray sensors with energy resolution of better than one part in 3,000 at 6 keV X-rays. While bismuth is an excellent material for high X-ray stopping power and low heat capacity (for large signal when an X-ray is stopped by the absorber), oxidation of the bismuth surface can lead to electron traps and other effects that degrade the energy resolution. Bismuth oxide reduction and nitride passivation techniques analogous to those used in indium passivation are being applied in a new technique. The technique will enable improved energy resolution and resistance to aging in bismuth-absorber-coupled X-ray sensors. Elemental bismuth is lithographically integrated into X-ray detector circuits. It encounters several steps where the Bi oxidizes. The technology discussed here will remove oxide from the surface of the Bi and replace it with nitridized surface. Removal of the native oxide and passivating to prevent the growth of the oxide will improve detector performance and insulate the detector against future degradation from oxide growth. Placing the Bi coated sensor in a vacuum system, a reduction chemistry in a plasma (nitrogen/hydrogen (N2/H2) + argon) is used to remove the oxide and promote nitridization of the cleaned Bi surface. Once passivated, the Bi will perform as a better X-ray thermalizer since energy will not be trapped in the bismuth oxides on the surface. A simple additional step, which can be added at various stages of the current fabrication process, can then be applied to encapsulate the Bi film. After plasma passivation, the Bi can be capped with a non-diffusive layer of metal or dielectric. A non-superconducting layer is required such as tungsten or tungsten nitride (WNx).

  18. Experimental investigation of egg ovalbumin scaling on heated stainless steel surface and scale-removal compared with that of whey protein.

    PubMed

    Li, Lin; Lv, Hui Ting; Deng, Ren Pan; Liao, Zhen Kai; Wu, Xue E; Chen, Xiao Dong

    2013-07-01

    Fouling and cleaning on a heat exchanger surface during milk processing have been studied extensively in the past due to their great importance in energy, product quality, and safety. However, little information is available for egg ovalbumin (OVA) fouling and cleaning behavior. In the present work, fouling and cleaning behaviors of OVA were investigated using a real-time monitoring system for heat transfer coefficient. A comparison was made between the behavior of whey protein concentrate (WPC) and that of OVA. WPC has been well studied which can be used as a benchmark. Ultrasonic cleaning was also applied to investigate the cleaning behavior of OVA fouling. Results have shown that OVA created more thermal resistance than WPC in the 2 h fouling process. It was also much more difficult to remove the OVA deposit than the WPC fouling. Different from what were observed from WPC deposit, there was no optimal cleaning rate for OVA deposit in the NaOH concentration range tested (0-2.0 wt%), while WPC fouling is known to have the highest cleaning rate around 0.5 wt% NaOH concentration at moderate temperatures.

  19. One-dimensional modeling of radial heat removal during depressurized heatup transients in modular pebble-bed and prismatic high temperature gas-cooled reactors

    SciTech Connect

    Savage, M.G.

    1984-07-01

    A one-dimensional computational model was developed to evaluate the heat removal capabilities of both prismatic-core and pebble-bed modular HTGRs during depressurized heatup transients. A correlation was incorporated to calculate the temperature- and neutron-fluence-dependent thermal conductivity of graphite. The modified Zehner-Schluender model was used to determine the effective thermal conductivity of a pebble bed, accounting for both conduction and radiation. Studies were performed for prismatic-core and pebble-bed modular HTGRs, and the results were compared to analyses performed by GA and GR, respectively. For the particular modular reactor design studied, the prismatic HTGR peak temperature was 2152.2/sup 0/C at 38 hours following the transient initiation, and the pebble-bed peak temperature was 1647.8/sup 0/C at 26 hours. These results compared favorably with those of GA and GE, with only slight differences caused by neglecting axial heat transfer in a one-dimensional radial model. This study found that the magnitude of the initial power density had a greater effect on the temperature excursion than did the initial temperature.

  20. Passive restriction of blood flow and counter-current heat exchange via lingual retia in the tongue of a neonatal gray whale Eschrichtius robustus (Cetacea, Mysticeti).

    PubMed

    Ekdale, Eric G; Kienle, Sarah S

    2015-04-01

    Retia mirabilia play broad roles in cetacean physiology, including thermoregulation during feeding and pressure regulations during diving. Vascular bundles of lingual retia are described within the base of the tongue of a neonatal female gray whale (Eschrichtius robustus). Each rete consists of a central artery surrounded by four to six smaller veins. The retia and constituent vessels decrease in diameter as they extend anteriorly within the hyoglossus muscle from a position anterior to the basihyal cartilage toward the apex of the tongue. The position of the retia embedded in the hyoglossus and the anterior constriction of the vessels differs from reports of similar vascular bundles that were previously identified in gray whales. The retia likely serve as a counter-current heat exchange system to control body temperature during feeding. Cold blood flowing toward the body center within the periarterial veins would accept heat from warm blood in the central artery flowing toward the anterior end of the tongue. Although thermoregulatory systems have been identified within the mouths of a few mysticete species, the distribution of such vascular structures likely is more widespread among baleen whales than has previously been described.

  1. Energy savings obtainable through passive solar techniques

    SciTech Connect

    Balcomb, J.D.

    1980-01-01

    A passive solar energy system is one in which the thermal energy flow is by natural means, that is by radiation, conduction, or natural convection. The purpose of the paper is to provide a survey of passive solar heating experience, especially in the US. Design approaches are reviewed and examples shown. Misconceptions are discussed. Advantages are listed. The Los Alamos program of performance simulation and evaluation is described and a simplified method of performance estimation is outlined.

  2. An assessment of RELAP5 MOD3.1.1 condensation heat transfer modeling with GIRAFFE heat transfer tests

    SciTech Connect

    Boyer, B.D.; Parlatan, Y.; Slovik, G.C.

    1995-09-01

    RELAP5 MOD3.1.1 is being used to simulate Loss of Coolant Accidents (LOCA) for the Simplified Boiling Water Reactor (SBWR) being proposed by General Electric (GE). One of the major components associated with the SBWR is the Passive Containment Cooling System (PCCS) which provides the long-term heat sink to reject decay heat. The RELAP5 MOD3.1.1 code is being assessed for its ability to represent accurately the PCCS. Data from the Phase 1, Step 1 Heat Transfer Tests performed at Toshiba`s Gravity-Driven Integral Full-Height Test for Passive Heat Removal (GIRAFFE) facility will be used for assessing the ability of RELAP5 to model condensation in the presence of noncondensables. The RELAP5 MOD3.1.1 condensation model uses the University of California at Berkeley (UCB) correlation developed by Vierow and Schrock. The RELAP5 code uses this heat transfer coefficient with the gas velocity effect multiplier being limited to 2. This heat transfer option was used to analyze the condensation heat transfer in the GIRAFFE PCCS heat exchanger tubes in the Phase 1, Step 1 Heat Transfer Tests which were at a pressure of 3 bar and had a range of nitrogen partial pressure fractions from 0.0 to 0.10. The results of a set of RELAP5 calculations at these conditions were compared with the GIRAFFE data. The effects of PCCS cell noding on the heat transfer process were also studied. The UCB correlation, as implemented in RELAP5, predicted the heat transfer to {plus_minus}5% of the data with a three--node model. The three-node model has a large cell in the entrance region which smeared out the entrance effects on the heat transfer, which tend to overpredict the condensation. Hence, the UCB correlation predicts condensation heat transfer correlation implemented in the code must be removed to allow for accurate calculations with smaller cell sizes.

  3. Passive-solar greenhouse

    SciTech Connect

    Not Available

    1982-01-01

    Our project objective was to design, construct, and operate a commercialized (16' x 50') passive, solar greenhouse. The structure was originally intended as a vegetable forcing facility to produce vegetable crops in the off-season. Building and size constraints and economic considerations convinced us to use the greenhouse for producing bedding plants and vegetable starts in the spring, high value vegetables (tomatoes, cucumbers) in the fall and forced bulbs in the winter. This crop sequence allows us to use the greenhouse all year without additional heat as the crops are adopted to the temperature regime of the greenhouse during each particular season. In our first season, the greenhouse performed beautifully. The lowest temperature recorded was 38/sup 0/F after 4 cold, cloudy days in February. The production of bedding plants has allowed us to diversify our products and the early transplants we produced were a great asset to our vegetable farming operation. Although construction cost (4.57 sq. ft.) is higher than that of a conventional polyethylene-covered, quonset-type greenhouse (approx. $1.92 sq. ft.), our annual operating cost is cheaper than that of a conventional greenhouse (0.49 cents sq. ft. versus 0.67 cents sq. ft.) due to a longer usable lifetime of the structure and the elimination of heating costs. Our structure has been toured by interested individuals, school and farm groups. We plan to publicize the structure and its advantages by promoting more visits to the site.

  4. Fundamental studies on passivity and passivity breakdown

    SciTech Connect

    Macdonald, D.D.; Urquidi-Macdonald, M.

    1993-06-01

    Using photoelectrochemical impedance and admittance spectroscopies, a fundamental and quantitative understanding of the mechanisms for the growth and breakdown of passive films on metal and alloy surfaces in contact with aqueous environments is being developed. A point defect model has been extended to explain the breakdown of passive films, leading to pitting and crack growth and thus development of damage due to localized corrosion.

  5. Passive cooling system for a vehicle

    DOEpatents

    Hendricks, Terry Joseph; Thoensen, Thomas

    2005-11-15

    A passive cooling system for a vehicle (114) transfers heat from an overheated internal component, for example, an instrument panel (100), to an external portion (116) of the vehicle (114), for example, a side body panel (126). The passive cooling system includes one or more heat pipes (112) having an evaporator section (118) embedded in the overheated internal component and a condenser section (120) at the external portion (116) of the vehicle (114). The evaporator (118) and condenser (120) sections are in fluid communication. The passive cooling system may also include a thermally conductive film (140) for thermally connecting the evaporator sections (118) of the heat pipes (112) to each other and to the instrument panel (100).

  6. Passive Cooling System for a Vehicle

    DOEpatents

    Hendricks, T. J.; Thoensen, T.

    2005-11-15

    A passive cooling system for a vehicle (114) transfers heat from an overheated internal component, for example, an instrument panel (100), to an external portion (116) of the vehicle (114), for example, a side body panel (126). The passive cooling system includes one or more heat pipes (112) having an evaporator section (118) embedded in the overheated internal component and a condenser section (120) at the external portion (116) of the vehicle (114). The evaporator (118) and condenser (120) sections are in fluid communication. The passive cooling system may also include a thermally conductive film (140) for thermally connecting the evaporator sections (118) of the heat pipes (112) to each other and to the instrument panel (100).

  7. Tropospheric Passive Remote Sensing

    NASA Technical Reports Server (NTRS)

    Keafer, L. S., Jr. (Editor)

    1982-01-01

    The long term role of airborne/spaceborne passive remote sensing systems for tropospheric air quality research and the identification of technology advances required to improve the performance of passive remote sensing systems were discussed.

  8. Interlanguage Passive Construction

    ERIC Educational Resources Information Center

    Simargool, Nirada

    2008-01-01

    Because the appearance of the passive construction varies cross linguistically, differences exist in the interlanguage (IL) passives attempted by learners of English. One such difference is the widely studied IL pseudo passive, as in "*new cars must keep inside" produced by Chinese speakers. The belief that this is a reflection of L1 language…

  9. Heat pipe methanator

    DOEpatents

    Ranken, William A.; Kemme, Joseph E.

    1976-07-27

    A heat pipe methanator for converting coal gas to methane. Gravity return heat pipes are employed to remove the heat of reaction from the methanation promoting catalyst, transmitting a portion of this heat to an incoming gas pre-heat section and delivering the remainder to a steam generating heat exchanger.

  10. Passively Q-switched side pumped monolithic ring laser

    NASA Technical Reports Server (NTRS)

    Li, Steven X. (Inventor)

    2012-01-01

    Disclosed herein are systems and methods for generating a side-pumped passively Q-switched non-planar ring oscillator. The method introduces a laser into a cavity of a crystal, the cavity having a round-trip path formed by a reflection at a dielectrically coated front surface, a first internal reflection at a first side surface of the crystal at a non-orthogonal angle with the front, a second internal reflection at a top surface of the crystal, and a third internal reflection at a second side surface of the crystal at a non-orthogonal angle with the front. The method side pumps the laser at the top or bottom surface with a side pump diode array beam and generates an output laser emanating at a location on the front surface. The design can include additional internal reflections to increase interaction with the side pump. Waste heat may be removed by mounting the crystal to a heatsink.

  11. [Fundamental studies of passivity and passivity breakdown

    SciTech Connect

    Macdonald, D.D.

    1993-07-01

    We developed and experimentally tested physical models for growth and breakdown of passive films on metal surfaces. These models are ``point defect models,`` in which the growth and breakdown are described in terms of movement of anion and cation vacancies. The work during the past 5 years resulted in: theory of growth and breakdown of passive films, theory of corrosion-resistant alloys, electronic structure of passive films, and estimation of damage functions for energy systems. Proposals are give for the five ongoing tasks. 10 figs.

  12. PCM Passive Cooling System Containing Active Subsystems

    NASA Technical Reports Server (NTRS)

    Blanding, David E.; Bass, David I.

    2005-01-01

    A multistage system has been proposed for cooling a circulating fluid that is subject to intermittent intense heating. The system would be both flexible and redundant in that it could operate in a basic passive mode, either sequentially or simultaneously with operation of a first, active cooling subsystem, and either sequentially or simultaneously with a second cooling subsystem that could be active, passive, or a combination of both. This flexibility and redundancy, in combination with the passive nature of at least one of the modes of operation, would make the system more reliable, relative to a conventional cooling system. The system would include a tube-in-shell heat exchanger, within which the space between the tubes would be filled with a phase-change material (PCM). The circulating hot fluid would flow along the tubes in the heat exchanger. In the basic passive mode of operation, heat would be conducted from the hot fluid into the PCM, wherein the heat would be stored temporarily by virtue of the phase change.

  13. Heat collector

    DOEpatents

    Merrigan, Michael A.

    1984-01-01

    A heat collector and method suitable for efficiently and cheaply collecting solar and other thermal energy are provided. The collector employs a heat pipe in a gravity-assist mode and is not evacuated. The collector has many advantages, some of which include ease of assembly, reduced structural stresses on the heat pipe enclosure, and a low total materials cost requirement. Natural convective forces drive the collector, which after startup operates entirely passively due in part to differences in molecular weights of gaseous components within the collector.

  14. Heat collector

    DOEpatents

    Merrigan, M.A.

    1981-06-29

    A heat collector and method suitable for efficiently and cheaply collecting solar and other thermal energy are provided. The collector employs a heat pipe in a gravity-assist mode and is not evacuated. The collector has many advantages, some of which include ease of assembly, reduced structural stresses on the heat pipe enclosure, and a low total materials cost requirement. Natural convective forces drive the collector, which after startup operates entirely passively due in part to differences in molecular weights of gaseous components within the collector.

  15. HEAT EXCHANGER

    DOEpatents

    Fox, T.H. III; Richey, T. Jr.; Winders, G.R.

    1962-10-23

    A heat exchanger is designed for use in the transfer of heat between a radioactive fiuid and a non-radioactive fiuid. The exchanger employs a removable section containing the non-hazardous fluid extending into the section designed to contain the radioactive fluid. The removable section is provided with a construction to cancel out thermal stresses. The stationary section is pressurized to prevent leakage of the radioactive fiuid and to maintain a safe, desirable level for this fiuid. (AEC)

  16. Validation of the integration of CFD and SAS4A/SASSYS-1: Analysis of EBR-II shutdown heat removal test 17

    SciTech Connect

    Thomas, J. W.; Fanning, T. H.; Vilim, R.; Briggs, L. L.

    2012-07-01

    Recent analyses have demonstrated the need to model multidimensional phenomena, particularly thermal stratification in outlet plena, during safety analyses of loss-of-flow transients of certain liquid-metal cooled reactor designs. Therefore, Argonne's reactor systems safety code SAS4A/SASSYS-1 is being enhanced by integrating 3D computational fluid dynamics models of the plena. A validation exercise of the new tool is being performed by analyzing the protected loss-of-flow event demonstrated by the EBR-II Shutdown Heat Removal Test 17. In this analysis, the behavior of the coolant in the cold pool is modeled using the CFD code STAR-CCM+, while the remainder of the cooling system and the reactor core are modeled with SAS4A/SASSYS-1. This paper summarizes the code integration strategy and provides the predicted 3D temperature and velocity distributions inside the cold pool during SHRT-17. The results of the coupled analysis should be considered preliminary at this stage, as the exercise pointed to the need to improve the CFD model of the cold pool tank. (authors)

  17. Skin lesion removal

    MedlinePlus

    ... focused on a very small area. The laser heats the cells in the area being treated until they "burst." There are several types of lasers. Each laser has specific uses. Laser excision can remove: Benign or pre- ...

  18. Passive compact molten salt reactor (PCMSR), modular thermal breeder reactor with totally passive safety system

    NASA Astrophysics Data System (ADS)

    Harto, Andang Widi

    2012-06-01

    Design Study Passive Compact Molten Salt Reactor (PCMSR) with totally passive safety system has been performed. The term of Compact in the PCMSR name means that the reactor system is designed to have relatively small volume per unit power output by using modular and integral concept. In term of modular, the reactor system consists of three modules, i.e. reactor module, turbine module and fuel management module. The reactor module is an integral design that consists of reactor, primary and intermediate heat exchangers and passive post shutdown cooling system. The turbine module is an integral design of a multi heating, multi cooling, regenerative gas turbine. The fuel management module consists of all equipments related to fuel preparation, fuel reprocessing and radioactive handling. The preliminary calculations show that the PCMSR has negative temperature and void reactivity coefficient, passive shutdown characteristic related to fuel pump failure and possibility of using natural circulation for post shutdown cooling system.

  19. Passive compact molten salt reactor (PCMSR), modular thermal breeder reactor with totally passive safety system

    SciTech Connect

    Harto, Andang Widi

    2012-06-06

    Design Study Passive Compact Molten Salt Reactor (PCMSR) with totally passive safety system has been performed. The term of Compact in the PCMSR name means that the reactor system is designed to have relatively small volume per unit power output by using modular and integral concept. In term of modular, the reactor system consists of three modules, i.e. reactor module, turbine module and fuel management module. The reactor module is an integral design that consists of reactor, primary and intermediate heat exchangers and passive post shutdown cooling system. The turbine module is an integral design of a multi heating, multi cooling, regenerative gas turbine. The fuel management module consists of all equipments related to fuel preparation, fuel reprocessing and radioactive handling. The preliminary calculations show that the PCMSR has negative temperature and void reactivity coefficient, passive shutdown characteristic related to fuel pump failure and possibility of using natural circulation for post shutdown cooling system.

  20. New PANDA Tests to Investigate Effects of Light Gases on Passive Safety Systems

    SciTech Connect

    Paladino, D.; Auban, O.; Candreia, P.; Huggenberger, M.; Strassberger, H.J.

    2002-07-01

    The large- scale thermal-hydraulic PANDA facility (located at PSI in Switzerland), has been used over the last few years for investigating different passive decay- heat removal systems and containment phenomena for the next generation of light water reactors (Simplified Boiling Water Reactor: SBWR; European Simplified Boiling Water Reactor: ESBWR; Siedewasserreaktor: SWR-1000). Currently, as part of the European Commission 5. EURATOM Framework Programme project 'Testing and Enhanced Modelling of Passive Evolutionary Systems Technology for Containment Cooling' (TEMPEST), a new series of tests is being planned in the PANDA facility to experimentally investigate the distribution of non-condensable gases inside the containment and their effect on the performance of the 'Passive Containment Cooling System' (PCCS). Hydrogen release caused by the metal-water reaction in the case of a postulated severe accident will be simulated in PANDA by injecting helium into the reactor pressure vessel. In order to provide suitable data for Computational Fluid Dynamic (CFD) code assessment and improvement, the instrumentation in PANDA has been upgraded for the new tests. In the present paper, a detailed discussion is given of the new PANDA tests to be performed to investigate the effects of light gas on passive safety systems. The tests are scheduled for the first half of the year 2002. (authors)

  1. Morphological evolution of voids by surface drift diffusion driven by capillary, electromigration, and thermal-stress gradients induced by steady-state heat flow in passivated metallic thin films and flip chip solder joints. I. Theory

    NASA Astrophysics Data System (ADS)

    Ogurtani, Tarik Omer; Akyildiz, Oncu

    2008-07-01

    The morphological evolution of intragranular voids induced by surface drift diffusion under the actions of capillary and electromigration (EM) forces and thermal-stress gradients (TSGs) associated with steady-state heat flow is investigated in passivated metallic thin films and flip chip solder joints via computer simulation using the front-tracking method. In the mesoscopic nonequilibrium thermodynamic formulation of the generalized driving forces for the thermal-stress-induced surface drift diffusion, not only the usual elastic strain energy density contribution but also the elastic dipole tensor interaction (EDTI) between the thermal-stress field and the mobile atomic species (monovacancies) are considered using the concept of elastic interaction energy promoted in unified linear instability analysis (ULISA) [T. O. Ogurtani, Phys. Rev. B 74, 155422 (2006)]. According to extensive computer experiments performed on voids, which are initially cylindrical in shape, two completely different and topographically distinct behaviors are observed during the development of quasistationary state void surface morphologies, even in the presence of strong EM forces. These behaviors strictly depend on whether or not heat flux crowding occurs in the regions between the void surface layer and the sidewalls of the interconnect lines due to proximity effects of the insulating boundaries. In both morphological cases, however, one also observes two well-defined regimes, namely, the EM and TSG dominated regimes in EM versus EDTI parametric space. In the case of the TSG dominated regime, the void center of gravity (centroid) exhibits uniform displacement (drift) velocity proportional and opposite to the induced TSG exactly as predicted by ULISA theory. These domains are bounded by a threshold level curve for the EDTI parameter, above which an extremely sharp crack tip nucleation and propagation occurs in the highly localized minima in the triaxial stress regions (i.e., hot spots

  2. Passive solar energy in Washington: Results of the Washington passive solar design/build/competition

    NASA Astrophysics Data System (ADS)

    1982-03-01

    The Washington Passive Solar Design and Build Competition was held in an effort to encourage the design, construction, and marketing of moderately priced passive solar homes in Washington state. Four categories were established, including single and multi-family, new design and remodel. A number of commonly made thermal mistakes are discussed. Eight winning entries are presented along with four notable entries, for each of which is given as an overview of the design, energy conservation measures, passive heating and cooling features, system operation, and thermal performance.

  3. Mennonite Nursing Home passive solar demonstration

    SciTech Connect

    Not Available

    1984-03-01

    A long-term nursing care facility and retirement center was designed for passive solar heating. The system comprises thermal mass, thermal insulation, Trombe walls, and direct gain clerestories. Included here is a topical report, analysis of building performance, owner's perspective, designer's perspective, and summary of information dissemination activities. (MHR)

  4. Passive safety injection system using borated water

    SciTech Connect

    Conway, Lawrence E.; Schulz, Terry L.

    1993-01-01

    A passive safety injection system relies on differences in water density to induce natural circulatory flow patterns which help maintain prescribed concentrations of boric acid in borated water, and prevents boron from accumulating in the reactor vessel and possibly preventing heat transfer.

  5. Trends vs. reactor size of passive reactivity shutdown and control performance

    SciTech Connect

    Wade, D.C.; Fujita, E.K.

    1987-01-01

    For LMR concepts, the goal of passive reactivity shutdown has been approached in the US by designing the reactors for favorable relationships among the power, power/flow, and inlet temperature coefficients of reactivity, for high internal conversion ratio (yielding small burnup control swing), and for a primary pump coastdown time appropriately matched to the delayed neutron hold back of power decay upon negative reactivity input. The use of sodium bonded metallic fuel pins has facilitated the achievement of the massive shutdown design goals as a consequence of their high thermal conductivity and high effective heavy metal density. Alternately, core designs based on derated oxide pins may be able to achieve the passive shutdown features at the cost of larger core volume and increased initial fissile inventory. For LMR concepts, the passive decay heat removal goal of inherent safety has been approached in US designs by use of pool layouts, larger surface to volume ratio of the reactor vessel with natural draft air cooling of the vessel surface, elevations and redans which promote natural circulation through the core, and thermal mass of the pool contents sufficient to absorb that initial transient decay heat which exceeds the natural draft air cooling capacity. This paper describes current US ''inherently safe'' reactor design.

  6. An investigation of a passively controlled haptic interface

    SciTech Connect

    Davis, J.T.; Book, W.J.

    1997-03-01

    Haptic interfaces enhance cooperation between humans and robotic manipulators by providing force and tactile feedback to the human user during the execution of arbitrary tasks. The use of active actuators in haptic displays presents a certain amount of risk since they are capable of providing unacceptable levels of energy to the systems upon which they operate. An alternative to providing numerous safeguards is to remove the sources of risk altogether. This research investigates the feasibility of trajectory control using passive devices, that is, devices that cannot add energy to the system. Passive actuators are capable only of removing energy from the system or transferring energy within the system. It is proposed that the utility of passive devices is greatly enhanced by the use of redundant actuators. In a passive system, once motion is provided to the system, presumably by a human user, passive devices may be able to modify this motion to achieve a desired resultant trajectory. A mechanically passive, 2-Degree-of-Freedom (D.O.F.) manipulator has been designed and built. It is equipped with four passive actuators: two electromagnetic brakes and two electromagnetic clutches. This paper gives a review of the literature on passive and robotics and describes the experimental test bed used in this research. Several control algorithms are investigated, resulting in the formulation of a passive control law.

  7. Novel Power Electronics Three-Dimensional Heat Exchanger: Preprint

    SciTech Connect

    Bennion, K.; Cousineau, J.; Lustbader, J.; Narumanchi, S.

    2014-08-01

    Electric drive systems for vehicle propulsion enable technologies critical to meeting challenges for energy, environmental, and economic security. Enabling cost-effective electric drive systems requires reductions in inverter power semiconductor area. As critical components of the electric drive system are made smaller, heat removal becomes an increasing challenge. In this paper, we demonstrate an integrated approach to the design of thermal management systems for power semiconductors that matches the passive thermal resistance of the packaging with the active convective cooling performance of the heat exchanger. The heat exchanger concept builds on existing semiconductor thermal management improvements described in literature and patents, which include improved bonded interface materials, direct cooling of the semiconductor packages, and double-sided cooling. The key difference in the described concept is the achievement of high heat transfer performance with less aggressive cooling techniques by optimizing the passive and active heat transfer paths. An extruded aluminum design was selected because of its lower tooling cost, higher performance, and scalability in comparison to cast aluminum. Results demonstrated a heat flux improvement of a factor of two, and a package heat density improvement over 30%, which achieved the thermal performance targets.

  8. Passive recirculation in the National Launch System's fuel feedlines

    NASA Technical Reports Server (NTRS)

    Wilson, W. R.; Holt, K. A.

    1993-01-01

    This report contains the passive recirculation tests on the fuel feedline of the National Launch System (NLS). The majority of testing was performed in February 1992, at the National Institute of Standards and Technology in Boulder, CO. The primary objective was to characterize passive recirculation in the NLS fuel feedline. The objective was met by observing the passive recirculation in a one-fifth scale model of the feedline with clear glass sections. The testing was recorded on video tape and with photographs. A description of the testing apparatus and support equipment is included. The experiment indicates that passive recirculation was occurring; higher angles from the horizontal transfer more heat.

  9. Condensation in horizontal heat exchanger tubes

    SciTech Connect

    Leyer, S.; Zacharias, T.; Maisberger, F.; Lamm, M.; Vallee, C.; Beyer, M.; Hampel, U.

    2012-07-01

    Many innovative reactor concepts for Generation III nuclear power plants use passive safety equipment for residual heat removal. These systems use two phase natural circulation. Heat transfer to the coolant results in a density difference providing the driving head for the required mass flow. By balancing the pressure drop the system finds its operational mode. Therefore the systems depend on a strong link between heat transfer and pressure drop determining the mass flow through the system. In order to be able to analyze these kind of systems with the help of state of the art computer codes the implemented numerical models for heat transfer, pressure drop or two phase flow structure must be able to predict the system performance in a wide parameter range. Goal of the program is to optimize the numerical models and therefore the performance of computer codes analyzing passive systems. Within the project the heat transfer capacity of a heat exchanger tube will be investigated. Therefore the tube will be equipped with detectors, both temperature and pressure, in several directions perpendicular to the tube axis to be able to resolve the angular heat transfer. In parallel the flow structure of a two phase flow inside and along the tube will be detected with the help of x-ray tomography. The water cooling outside of the tube will be realized by forced convection. It will be possible to combine the flow structure measurement with an angular resolved heat transfer for a wide parameter range. The test rig is set up at the TOPLFOW facility at the Helmholtz-Zentrum Dresden-Rossendorf (HZDR), so that it will be possible to vary the pressure between 5 and 70 bar. The steam mass content will be varied between 0 and 100 percent. The results will be compared to the large scaled Emergency Condenser Tests performed at the INKA test facility in Karlstein (Germany). The paper will explain the test setup and the status of the project will be presented. (authors)

  10. Passive magnetic bearing configurations

    DOEpatents

    Post, Richard F.

    2011-01-25

    A journal bearing provides vertical and radial stability to a rotor of a passive magnetic bearing system when the rotor is not rotating and when it is rotating. In the passive magnetic bearing system, the rotor has a vertical axis of rotation. Without the journal bearing, the rotor is vertically and radially unstable when stationary, and is vertically stable and radially unstable when rotating.

  11. Overcoming Passive Behavior.

    ERIC Educational Resources Information Center

    Kay, Marilyn

    1986-01-01

    Passivity in learning disabled children is identified as either inborn or as "learned helplessness," and the role of the teacher in overcoming passivity is noted. Teachers can help students understand themselves, become active agents in learning, and use self monitoring devices. (CL)

  12. Thulium-170 heat source

    SciTech Connect

    Walter, C.E.; Van Konynenburg, R.; Van Sant, J.H.

    1992-01-21

    This patent describes an isotopic heat source. It comprises; at least one isotopic fuel stack, comprising alternating layers of: thulium oxide; and a low atomic weight diluent for thulium oxide; a heat block defining holes into which the fuel stacks can be placed; at least one heat pipe for heat removal, with the heat pipe being positioned in the heat block in thermal connection with the fuel stack; and a structural container surrounding the heat block.

  13. Passive solar construction handbook

    SciTech Connect

    Levy, E.; Evans, D.; Gardstein, C.

    1981-08-01

    Many of the basic elements of passive solar design are reviewed. The unique design constraints presented in passive homes are introduced and many of the salient issues influencing design decisions are described briefly. Passive solar construction is described for each passive system type: direct gain, thermal storage wall, attached sunspace, thermal storage roof, and convective loop. For each system type, important design and construction issues are discussed and case studies illustrating designed and built examples of the system type are presented. Construction details are given and construction and thermal performance information is given for the materials used in collector components, storage components, and control components. Included are glazing materials, framing systems, caulking and sealants, concrete masonry, concrete, brick, shading, reflectors, and insulators. The Load Collector Ratio method for estimating passive system performance is appended, and other analysis methods are briefly summarized. (LEW)

  14. Vertical Diffusivities of Active and Passive Tracers

    NASA Technical Reports Server (NTRS)

    Canuto, V. M.; Cheng, Y.; Howard, A. M.

    2010-01-01

    The climate models that include a carbon-cycle need the vertical diffusivity of a passive tracer. Since an expression for the latter is not available, it has been common practice to identify it with that of salt. The identification is questionable since T, S are active, not passive tracers. We present the first derivation of the diffusivity of a passive tracer in terms of Ri (Richardson number) and Rq (density ratio, ratio of salinity over temperature z-gradients). The following results have emerged: (a) The passive tracer diffusivity is an algebraic function of Ri, Rq. (b) In doubly stable regimes (DS, partial derivative of T with respect to z > 0, partial derivative of S with respect to z < 0), the passive scalar diffusivity is nearly the same as that of salt/heat for any values of Rq < 0 and Ri > 0. (c) In DC regimes (diffusive convection, partial derivative of T with respect to z < 0, partial derivative of S with respect to z < 0, Rq > 1), the passive scalar diffusivity is larger than that of salt. At Ri = O(1), it can be more than twice as large. (d) In SF regimes (salt fingers, partial derivative of T with respect to z > 0, partial derivative of S with respect to z > 0, Rq < 1), the passive scalar diffusivity is smaller than that of salt. At Ri = O(1), it can be less than half of it. (e) The passive tracer diffusivity predicted at the location of NATRE (North Atlantic Tracer Release Experiment) is discussed. (f) Perhaps the most relevant conclusion is that the common identification of the tracer diffusivity with that of salt is valid only in DS regimes. In the Southern Ocean, where there is the largest CO2 absorption, the dominant regime is diffusive convection discussed in (c) above.

  15. Mitigation of steam generator tube rupture in a pressurized water reactor with passive safety systems

    DOEpatents

    McDermott, Daniel J.; Schrader, Kenneth J.; Schulz, Terry L.

    1994-01-01

    The effects of steam generator tube ruptures in a pressurized water reactor are mitigated by reducing the pressure in the primary loop by diverting reactor coolant through the heat exchanger of a passive heat removal system immersed in the in containment refueling water storage tank in response to a high feed water level in the steam generator. Reactor coolant inventory is maintained by also in response to high steam generator level introducing coolant into the primary loop from core make-up tanks at the pressure in the reactor coolant system pressurizer. The high steam generator level is also used to isolate the start-up feed water system and the chemical and volume control system to prevent flooding into the steam header. 2 figures.

  16. Mitigation of steam generator tube rupture in a pressurized water reactor with passive safety systems

    DOEpatents

    McDermott, D.J.; Schrader, K.J.; Schulz, T.L.

    1994-05-03

    The effects of steam generator tube ruptures in a pressurized water reactor are mitigated by reducing the pressure in the primary loop by diverting reactor coolant through the heat exchanger of a passive heat removal system immersed in the in containment refueling water storage tank in response to a high feed water level in the steam generator. Reactor coolant inventory is maintained by also in response to high steam generator level introducing coolant into the primary loop from core make-up tanks at the pressure in the reactor coolant system pressurizer. The high steam generator level is also used to isolate the start-up feed water system and the chemical and volume control system to prevent flooding into the steam header. 2 figures.

  17. Anti-reverse siphon solar heating system

    SciTech Connect

    Larkin, W. J.

    1985-05-28

    A solar heater which is adapted for liquid heating and space heating, or both, utilizes a passive anti-reverse siphon concept in which fresh air or water is required to traverse upwardly along a passageway and then descend along a descending passageway insulated from the ascending passageway before it enters the solar heating chamber, with the result that the pressure heads generated in the ascending and descending passageways and the heating chamber offset one another such that forward, passive solar heating convection occurs, but in the evening when the heating chamber becomes cool, the normal reverse convection that occurs in passive units is stopped.

  18. Electrochemical-thermal modeling and microscale phase change for passive internal thermal management of lithium ion batteries.

    SciTech Connect

    Fuller, Thomas F.; Bandhauer, Todd; Garimella, Srinivas

    2012-01-01

    A fully coupled electrochemical and thermal model for lithium-ion batteries is developed to investigate the impact of different thermal management strategies on battery performance. In contrast to previous modeling efforts focused either exclusively on particle electrochemistry on the one hand or overall vehicle simulations on the other, the present work predicts local electrochemical reaction rates using temperature-dependent data on commercially available batteries designed for high rates (C/LiFePO{sub 4}) in a computationally efficient manner. Simulation results show that conventional external cooling systems for these batteries, which have a low composite thermal conductivity ({approx}1 W/m-K), cause either large temperature rises or internal temperature gradients. Thus, a novel, passive internal cooling system that uses heat removal through liquid-vapor phase change is developed. Although there have been prior investigations of phase change at the microscales, fluid flow at the conditions expected here is not well understood. A first-principles based cooling system performance model is developed and validated experimentally, and is integrated into the coupled electrochemical-thermal model for assessment of performance improvement relative to conventional thermal management strategies. The proposed cooling system passively removes heat almost isothermally with negligible thermal resistances between the heat source and cooling fluid. Thus, the minimization of peak temperatures and gradients within batteries allow increased power and energy densities unencumbered by thermal limitations.

  19. Open-loop heat-recovery dryer

    DOEpatents

    TeGrotenhuis, Ward Evan

    2013-11-05

    A drying apparatus is disclosed that includes a drum and an open-loop airflow pathway originating at an ambient air inlet, passing through the drum, and terminating at an exhaust outlet. A passive heat exchanger is included for passively transferring heat from air flowing from the drum toward the exhaust outlet to air flowing from the ambient air inlet toward the drum. A heat pump is also included for actively transferring heat from air flowing from the passive heat exchanger toward the exhaust outlet to air flowing from the passive heat exchanger toward the drum. A heating element is also included for further heating air flowing from the heat pump toward the drum.

  20. Combining Passive Thermography and Acoustic Emission for Large Area Fatigue Damage Growth Assessment of a Composite Structure

    NASA Technical Reports Server (NTRS)

    Zalameda, Joseph N.; Horne, Michael R.; Madaras, Eric I.; Burke, Eric R.

    2016-01-01

    Passive thermography and acoustic emission data were obtained for improved real time damage detection during fatigue loading. A strong positive correlation was demonstrated between acoustic energy event location and thermal heating, especially if the structure under load was nearing ultimate failure. An image processing routine was developed to map the acoustic emission data onto the thermal imagery. This required removing optical barrel distortion and angular rotation from the thermal data. The acoustic emission data were then mapped onto thermal data, revealing the cluster of acoustic emission event locations around the thermal signatures of interest. By combining both techniques, progression of damage growth is confirmed and areas of failure are identified. This technology provides improved real time inspections of advanced composite structures during fatigue testing.Keywords: Thermal nondestructive evaluation, fatigue damage detection, aerospace composite inspection, acoustic emission, passive thermography

  1. Climate-Specific Passive Building Standards

    SciTech Connect

    Wright, Graham S.; Klingenberg, Katrin

    2015-07-01

    Passive design principles (super insulation, airtight envelopes, elimination of thermal bridges, etc.) - pioneered in North America in the 70s and 80s and refined in Europe in the 90s have proven to be universally effective to significantly reduce heating and cooling loads. However, a single, rigid performance metric developed in Germany has led to limited uptake of passive building principles in many regions of the United States. It has also, in many cases, promoted some design decisions that had negative effects on economic feasibility and thermal comfort. This study's main objective is to validate (in a theoretical sense) verifiable, climate-specific passive standards and space conditioning criteria that retain ambitious, environmentally-necessary energy reduction targets and are economically feasible, such standards provide designers an ambitious but achievable performance target on the path to zero.

  2. Hood River Passive House

    SciTech Connect

    Hales, D.

    2013-03-01

    The Hood River Passive Project was developed by Root Design Build of Hood River Oregon using the Passive House Planning Package (PHPP) to meet all of the requirements for certification under the European Passive House standards. The Passive House design approach has been gaining momentum among residential designers for custom homes and BEopt modeling indicates that these designs may actually exceed the goal of the U.S. Department of Energy's (DOE) Building America program to reduce home energy use by 30%-50% (compared to 2009 energy codes for new homes). This report documents the short term test results of the Shift House and compares the results of PHPP and BEopt modeling of the project.

  3. Active heat exchange system development for latent heat thermal energy storage

    NASA Technical Reports Server (NTRS)

    Alario, J.; Kosson, R.; Haslett, R.

    1980-01-01

    Various active heat exchange concepts were identified from among three generic categories: scrapers, agitators/vibrators and slurries. The more practical ones were given a more detailed technical evaluation and an economic comparison with a passive tube-shell design for a reference application (300 MW sub t storage for 6 hours). Two concepts were selected for hardware development: (1) a direct contact heat exchanger in which molten salt droplets are injected into a cooler counterflowing stream of liquid metal carrier fluid, and (2) a rotating drum scraper in which molten salt is sprayed onto the circumference of a rotating drum, which contains the fluid salt is sprayed onto the circumference of a rotating drum, which contains the fluid heat sink in an internal annulus near the surface. A fixed scraper blade removes the solidified salt from the surface which was nickel plated to decrease adhesion forces. In addition to improving performance by providing a nearly constant transfer rate during discharge, these active heat exchanger concepts were estimated to cost at least 25% less than the passive tube-shell design.

  4. Passive adaptive imaging through turbulence

    NASA Astrophysics Data System (ADS)

    Tofsted, David

    2016-05-01

    Standard methods for improved imaging system performance under degrading optical turbulence conditions typically involve active adaptive techniques or post-capture image processing. Here, passive adaptive methods are considered where active sources are disallowed, a priori. Theoretical analyses of short-exposure turbulence impacts indicate that varying aperture sizes experience different degrees of turbulence impacts. Smaller apertures often outperform larger aperture systems as turbulence strength increases. This suggests a controllable aperture system is advantageous. In addition, sub-aperture sampling of a set of training images permits the system to sense tilts in different sub-aperture regions through image acquisition and image cross-correlation calculations. A four sub-aperture pattern supports corrections involving five realizable operating modes (beyond tip and tilt) for removing aberrations over an annular pattern. Progress to date will be discussed regarding development and field trials of a prototype system.

  5. Passive cooling system for nuclear reactor containment structure

    DOEpatents

    Gou, Perng-Fei; Wade, Gentry E.

    1989-01-01

    A passive cooling system for the contaminant structure of a nuclear reactor plant providing protection against overpressure within the containment attributable to inadvertent leakage or rupture of the system components. The cooling system utilizes natural convection for transferring heat imbalances and enables the discharge of irradiation free thermal energy to the atmosphere for heat disposal from the system.

  6. Natural circulating passive cooling system for nuclear reactor containment structure

    DOEpatents

    Gou, Perng-Fei; Wade, Gentry E.

    1990-01-01

    A passive cooling system for the contaminant structure of a nuclear reactor plant providing protection against overpressure within the containment attributable to inadvertent leakage or rupture of the system components. The cooling system utilizes natural convection for transferring heat imbalances and enables the discharge of irradiation free thermal energy to the atmosphere for heat disposal from the system.

  7. National Passive Solar Conference, 4th, Kansas City, MO, October 3-5, 1979, Proceedings. Volume 4

    NASA Astrophysics Data System (ADS)

    Franta, G.

    1981-10-01

    Papers concern recent experience in the research, development and application of passive solar technology. Specific topics include the legislative barriers and incentives to passive solar systems, coupled thermal and lighting simulations for evaluating daylighting design effectiveness, passive solar applications in inner city housing, radiative cooling in a desert climate, salinity gradient solar ponds, the retrofit of a masonry home for passive space heating, the performances of active and passive solar domestic hot water systems, builder experience with passive solar home construction, the use of solar energy installations on farm buildings, and a method of determining the thermal performance of passive storage walls.

  8. Thulium-170 heat source

    DOEpatents

    Walter, Carl E.; Van Konynenburg, Richard; VanSant, James H.

    1992-01-01

    An isotopic heat source is formed using stacks of thin individual layers of a refractory isotopic fuel, preferably thulium oxide, alternating with layers of a low atomic weight diluent, preferably graphite. The graphite serves several functions: to act as a moderator during neutron irradiation, to minimize bremsstrahlung radiation, and to facilitate heat transfer. The fuel stacks are inserted into a heat block, which is encased in a sealed, insulated and shielded structural container. Heat pipes are inserted in the heat block and contain a working fluid. The heat pipe working fluid transfers heat from the heat block to a heat exchanger for power conversion. Single phase gas pressure controls the flow of the working fluid for maximum heat exchange and to provide passive cooling.

  9. Thulium-170 heat source

    SciTech Connect

    Walter, C.E.; Van Konynenburg, R.; VanSant, J.H.

    1990-09-06

    An isotopic heat source is formed using stacks of thin individual layers of a refractory isotopic fuel, preferably thulium oxide, alternating with layers of a low atomic weight diluent, preferably graphite. The graphite serves several functions: to act as a moderator during neutron irradiation, to minimize bremsstrahlung radiation, and to facilitate heat transfer. The fuel stacks are inserted into a heat block, which is encased in a sealed, insulated and shielded structural container. Heat pipes are inserted in the heat block and contain a working fluid. The heat pipe working fluid transfers heat from the heat block to a heat exchanger for power conversion. Single phase gas pressure controls the flow of the working fluid for maximum heat exchange and to provide passive cooling.

  10. Passively cooled direct drive wind turbine

    DOEpatents

    Costin, Daniel P.

    2008-03-18

    A wind turbine is provided that passively cools an electrical generator. The wind turbine includes a plurality of fins arranged peripherally around a generator house. Each of the fins being oriented at an angle greater than zero degrees to allow parallel flow of air over the fin. The fin is further tapered to allow a constant portion of the fin to extend beyond the air stream boundary layer. Turbulence initiators on the nose cone further enhance heat transfer at the fins.

  11. Tierra Nueva -- A passive solar cohousing project

    SciTech Connect

    Haggard, K.; Cooper, P.

    1999-10-01

    California architects take on the formidable challenges of designing a cohousing project, and discover that the end result is well worth the effort. The Tierra Nueva Cohousing Project consists of living units, a common house, community orchard, community gardens, community play space, space for a future shop and at the periphery of the site, parking, carports and garages. The units use thermal mass, solar heating, passive solar cooling, perimeter insulation on slabs. Design was agreed to by the community as a whole.

  12. Loop Heat Pipe with Thermal Control Valve as a Variable Thermal Link

    NASA Technical Reports Server (NTRS)

    Hartenstine, John; Anderson, William G.; Walker, Kara; Dussinger, Pete

    2012-01-01

    Future lunar landers and rovers will require variable thermal links that allow for heat rejection during the lunar daytime and passively prevent heat rejection during the lunar night. During the lunar day, the thermal management system must reject the waste heat from the electronics and batteries to maintain them below the maximum acceptable temperature. During the lunar night, the heat rejection system must either be shut down or significant amounts of guard heat must be added to keep the electronics and batteries above the minimum acceptable temperature. Since guard heater power is unfavorable because it adds to system size and complexity, a variable thermal link is preferred to limit heat removal from the electronics and batteries during the long lunar night. Conventional loop heat pipes (LHPs) can provide the required variable thermal conductance, but they still consume electrical power to shut down the heat transfer. This innovation adds a thermal control valve (TCV) and a bypass line to a conventional LHP that proportionally allows vapor to flow back into the compensation chamber of the LHP. The addition of this valve can achieve completely passive thermal control of the LHP, eliminating the need for guard heaters and complex controls.

  13. An assessment of RELAP5 MOD3.1.1 condensation heat transfer modeling with GIRAFFE heat transfer tests

    SciTech Connect

    Boyer, B.D.; Parlatan, Y.; Slovik, G.C.; Rohatgi, U.S.

    1995-09-01

    RELAP5 MOD3.1.1 is being used to simulate Loss of Coolant Accidents (LOCA) for the Simplified Boiling Water Reactor (SBWR) being proposed by General Electric (GE). One of the major components associated with the SBWR is the Passive Containment Cooling System (PCCS) which provides the long-term heat sink to reject decay heat. The RELAP5 MOD3.1.1 code is being assessed for its ability to represent accurately the PCCS. Data from the Phase 1, Step 1 Heat Transfer Tests performed at Toshiba`s Gravity-Driven Integral Full-Height Test for Passive Heat Removal (GIRAFFE) facility will be used for assessing the ability of RELAP5 to model condensation in the presence of noncondensables. The RELAP5 MOD3.1.1 condensation model uses the University of California at Berkeley (UCB) correlation developed by Vierow and Schrock. The RELAP5 code uses this heat transfer coefficient with the gas velocity effect multiplier being limited to 2. This heat transfer option was used to analyze the condensation heat transfer in the GIRAFFE PCCS heat exchanger tubes in the Phase 1, Step 1 Heat Transfer Tests which were at a pressure of 3 bar and had a range of nitrogen partial pressure fractions from 0.0 to 0.10. The results of a set of RELAP5 calculations al these conditions were compared with the GIRAFFE data. The effects of PCCS cell nodings on the heat transfer process were also studied. The UCB correlation, as implemented in RELAP5, predicted the heat transfer to {+-}5% of the data with a three-node model. The three-node model has a large cell in the entrance region which smeared out the entrance effects on the heat transfer, which tend to overpredict the condensation. Hence, the UCB correlation predicts condensation heat transfer in the presence of noncondensable gases with only a coarse mesh. The cell length term in the condensation heat transfer correlation implemented in the code must be removed to allow for accurate calculations with smaller cell sizes.

  14. Antimony Passivation of InP

    NASA Astrophysics Data System (ADS)

    Nobusawa, Hajime; Ikoma, Hideaki

    1993-09-01

    Antimony passivation of InP was investigated. Sb was evaporated on a HCl-etched InP substrate and annealed at 300°C for 10 min. I--V characteristics of the Au/Sb/InP diode are substantially improved and the Schottky barrier height becomes higher as compared with the conventional Au/InP diode. The reverse current decreases by about two orders of magnitude upon Sb passivation. X-ray photoelectron spectroscopic (XPS) measurements show that the Sb oxide, Sb2O3, is formed near both the surface and the interface, i.e., the Sb2O3/Sb/Sb2O3 layered structure exists on the InP substrate. On the other hand, In2O3, the dominant component species of the native oxide of InP, is not observed in the Sb-passivated sample, which indicates that Sb passivation effectively removes that native oxide (In2O3) and suppresses reoxidation of the InP surface. Sb is considered to reduce In2O3 and is oxidized itself to become Sb2O3. This is a probable mechanism of Sb passivation. After the Sb-passivated substrate is washed in deionized water, the amount of Sb decreases and In2O3 is again observed. This is explained by the balance in the chemical reaction between In2O3 and Sb2O3 (the mass-action law). The low Schottky barrier height and the poor electrical characteristics are thus well correlated with the existence of the native oxide of InP, dominantly, In2O3.

  15. Wireless passive radiation sensor

    SciTech Connect

    Pfeifer, Kent B; Rumpf, Arthur N; Yelton, William G; Limmer, Steven J

    2013-12-03

    A novel measurement technique is employed using surface acoustic wave (SAW) devices, passive RF, and radiation-sensitive films to provide a wireless passive radiation sensor that requires no batteries, outside wiring, or regular maintenance. The sensor is small (<1 cm.sup.2), physically robust, and will operate unattended for decades. In addition, the sensor can be insensitive to measurement position and read distance due to a novel self-referencing technique eliminating the need to measure absolute responses that are dependent on RF transmitter location and power.

  16. A corrosive resistant heat exchanger

    DOEpatents

    Richlen, S.L.

    1987-08-10

    A corrosive and erosive resistant heat exchanger which recovers heat from a contaminated heat stream. The heat exchanger utilizes a boundary layer of innocuous gas, which is continuously replenished, to protect the heat exchanger surface from the hot contaminated gas. The innocuous gas is pumped through ducts or perforations in the heat exchanger wall. Heat from the heat stream is transferred by radiation to the heat exchanger wall. Heat is removed from the outer heat exchanger wall by a heat recovery medium. 3 figs., 3 tabs.

  17. Method of passivating semiconductor surfaces

    DOEpatents

    Wanlass, Mark W.

    1990-01-01

    A method of passivating Group III-V or II-VI semiconductor compound surfaces. The method includes selecting a passivating material having a lattice constant substantially mismatched to the lattice constant of the semiconductor compound. The passivating material is then grown as an ultrathin layer of passivating material on the surface of the Group III-V or II-VI semiconductor compound. The passivating material is grown to a thickness sufficient to maintain a coherent interface between the ultrathin passivating material and the semiconductor compound. In addition, a device formed from such method is also disclosed.

  18. Method of passivating semiconductor surfaces

    DOEpatents

    Wanlass, M.W.

    1990-06-19

    A method is described for passivating Group III-V or II-VI semiconductor compound surfaces. The method includes selecting a passivating material having a lattice constant substantially mismatched to the lattice constant of the semiconductor compound. The passivating material is then grown as an ultrathin layer of passivating material on the surface of the Group III-V or II-VI semiconductor compound. The passivating material is grown to a thickness sufficient to maintain a coherent interface between the ultrathin passivating material and the semiconductor compound. In addition, a device formed from such method is also disclosed.

  19. Passive Cooling of Body Armor

    NASA Astrophysics Data System (ADS)

    Holtz, Ronald; Matic, Peter; Mott, David

    2013-03-01

    Warfighter performance can be adversely affected by heat load and weight of equipment. Current tactical vest designs are good insulators and lack ventilation, thus do not provide effective management of metabolic heat generated. NRL has undertaken a systematic study of tactical vest thermal management, leading to physics-based strategies that provide improved cooling without undesirable consequences such as added weight, added electrical power requirements, or compromised protection. The approach is based on evaporative cooling of sweat produced by the wearer of the vest, in an air flow provided by ambient wind or ambulatory motion of the wearer. Using an approach including thermodynamic analysis, computational fluid dynamics modeling, air flow measurements of model ventilated vest architectures, and studies of the influence of fabric aerodynamic drag characteristics, materials and geometry were identified that optimize passive cooling of tactical vests. Specific architectural features of the vest design allow for optimal ventilation patterns, and selection of fabrics for vest construction optimize evaporation rates while reducing air flow resistance. Cooling rates consistent with the theoretical and modeling predictions were verified experimentally for 3D mockups.

  20. HTR-100 industrial nuclear power plant for generation of heat and electricity

    SciTech Connect

    Brandes, S.; Kohl, W.

    1987-11-01

    Based on their proven high-temperature reactor (HTR) with pebble-bed core, Brown, Boveri and Cie/Hochtemperatur-Reaktorbau have developed an HTR-100 plant that combines favorable capital costs and high availability. Due to the high HTR-specific standards and passive safety features, this plant is especially well suited for siting near the end user. The safety concept permits further operation of the plant or decay heat removal via the operational heat sinks in the event of maloperation and design basis accidents having a higher probability of occurrence. In the event of hypothetical accidents, the decay heat is removed from the reactor pressure vessel by radiation, conduction, and convection to a concrete cooling system operating in natural convection. As an example of the new HTR-100 plant concept, a twin-block plant design for extraction of industrial steam is presented.

  1. Passive solar progress: a simplified guide to the 3rd national passive solar conference

    SciTech Connect

    Miller, H.; Howell, Y.; Richards, D.

    1980-10-01

    Some of the concepts and practices that have come to be known as passive solar heating and cooling are introduced, and a current picture of the field is presented. Much of the material presented is derived from papers given at the 3rd National Passive Solar Conference held in San Jose, California in January 1979 and sponsored by the US Department of Energy. Extracts and data from these papers have been integrated in the text with explanatory and descriptive material. In this way, it is attempted to present technical information in an introductory context. Topics include design considerations, passive and hybrid systems and applications, sizing methods and performance prediction, and implementation issues. A glossary is included. (WHK)

  2. Positioning Your Library for Solar (and Financial) Gain. Improving Energy Efficiency, Lighting, and Ventilation with Primarily Passive Techniques

    ERIC Educational Resources Information Center

    Shane, Jackie

    2012-01-01

    This article stresses the importance of building design above technology as a relatively inexpensive way to reduce energy costs for a library. Emphasis is placed on passive solar design for heat and daylighting, but also examines passive ventilation and cooling, green roofs, and building materials. Passive design is weighed against technologies…

  3. X-ray photoelectron spectroscopic study of the oxide removal mechanism of GaAs /100/ molecular beam epitaxial substrates in in situ heating

    NASA Technical Reports Server (NTRS)

    Vasquez, R. P.; Lewis, B. F.; Grunthaner, F. J.

    1983-01-01

    A standard cleaning procedure for GaAs (100) molecular beam epitaxial (MBE) substrates is a chemical treatment with a solution of H2SO4/H2O2/H2O, followed by in situ heating prior to MBE growth. X-ray photoelectron spectroscopic (XPS) studies of the surface following the chemical treatment show that the oxidized As is primarily As(+ 5). Upon heating to low temperatures (less than (350 C) the As(+ 5) oxidizes the substrate to form Ga2O3 and elemental As, and the As(+ 5) is reduced to As(+ 3) in the process. At higher temperatures (500 C), the As(+ 3) and elemental As desorb, while the Ga(+ 3) begins desorbing at about 600 C.

  4. Monogroove liquid heat exchanger

    NASA Technical Reports Server (NTRS)

    Brown, Richard F. (Inventor); Edelstein, Fred (Inventor)

    1990-01-01

    A liquid supply control is disclosed for a heat transfer system which transports heat by liquid-vapor phase change of a working fluid. An assembly (10) of monogroove heat pipe legs (15) can be operated automatically as either heat acquisition devices or heat discharge sources. The liquid channels (27) of the heat pipe legs (15) are connected to a reservoir (35) which is filled and drained by respective filling and draining valves (30, 32). Information from liquid level sensors (50, 51) on the reservoir (35) is combined (60) with temperature information (55) from the liquid heat exchanger (12) and temperature information (56) from the assembly vapor conduit (42) to regulate filling and draining of the reservoir (35), so that the reservoir (35) in turn serves the liquid supply/drain needs of the heat pipe legs (15), on demand, by passive capillary action (20, 28).

  5. Thermal-hydraulic simulation of natural convection decay heat removal in the High Flux Isotope Reactor (HFIR) using RELAP5 and TEMPEST: Part 2, Interpretation and validation of results

    SciTech Connect

    Ruggles, A.E.; Morris, D.G.

    1989-01-01

    The RELAP5/MOD2 code was used to predict the thermal-hydraulic behavior of the HFIR core during decay heat removal through boiling natural circulation. The low system pressure and low mass flux values associated with boiling natural circulation are far from conditions for which RELAP5 is well exercised. Therefore, some simple hand calculations are used herein to establish the physics of the results. The interpretation and validation effort is divided between the time average flow conditions and the time varying flow conditions. The time average flow conditions are evaluated using a lumped parameter model and heat balance. The Martinelli-Nelson correlations are used to model the two-phase pressure drop and void fraction vs flow quality relationship within the core region. Systems of parallel channels are susceptible to both density wave oscillations and pressure drop oscillations. Periodic variations in the mass flux and exit flow quality of individual core channels are predicted by RELAP5. These oscillations are consistent with those observed experimentally and are of the density wave type. The impact of the time varying flow properties on local wall superheat is bounded herein. The conditions necessary for Ledinegg flow excursions are identified. These conditions do not fall within the envelope of decay heat levels relevant to HFIR in boiling natural circulation. 14 refs., 5 figs., 1 tab.

  6. Mechanisms of Ocean Heat Uptake

    NASA Astrophysics Data System (ADS)

    Garuba, Oluwayemi

    An important parameter for the climate response to increased greenhouse gases or other radiative forcing is the speed at which heat anomalies propagate downward in the ocean. Ocean heat uptake occurs through passive advection/diffusion of surface heat anomalies and through the redistribution of existing temperature gradients due to circulation changes. Atlantic meridional overturning circulation (AMOC) weakens in a warming climate and this should slow the downward heat advection (compared to a case in which the circulation is unchanged). However, weakening AMOC also causes a deep warming through the redistributive effect, thus increasing the downward rate of heat propagation compared to unchanging circulation. Total heat uptake depends on the combined effect of these two mechanisms. Passive tracers in a perturbed CO2 quadrupling experiments are used to investigate the effect of passive advection and redistribution of temperature anomalies. A new passive tracer formulation is used to separate ocean heat uptake into contributions due to redistribution and passive advection-diffusion of surface heating during an ocean model experiment with abrupt increase in surface temperature. The spatial pattern and mechanisms of each component are examined. With further experiments, the effects of surface wind, salinity and temperature changes in changing circulation and the resulting effect on redistribution in the individual basins are isolated. Analysis of the passive advection and propagation path of the tracer show that the Southern ocean dominates heat uptake, largely through vertical and horizontal diffusion. Vertical diffusion transports the tracer across isopycnals down to about 1000m in 100 years in the Southern ocean. Advection is more important in the subtropical cells and in the Atlantic high latitudes, both with a short time scale of about 20 years. The shallow subtropical cells transport the tracer down to about 500m along isopycnal surfaces, below this vertical

  7. Preparation, characterization and dissolution of passive oxide film on the 400 series stainless steel surfaces

    NASA Astrophysics Data System (ADS)

    Sathyaseelan, V. S.; Rufus, A. L.; Chandramohan, P.; Subramanian, H.; Velmurugan, S.

    2015-12-01

    Full system decontamination of Primary Heat Transport (PHT) system of Pressurised Heavy Water Reactors (PHWRs) resulted in low decontamination factors (DF) on stainless steel (SS) surfaces. Hence, studies were carried out with 403 SS and 410 SS that are the material of construction of "End-Fitting body" and "End-Fitting Liner tubes". Three formulations were evaluated for the dissolution of passive films formed over these alloys viz., i) Two-step process consisting of oxidation and reduction reactions, ii) Dilute Chemical Decontamination (DCD) and iii) High Temperature Process. The two-step and high temperature processes could dissolve the oxide completely while the DCD process could remove only 60%. Various techniques like XRD, Raman spectroscopy and SEM-EDX were used for assessing the dissolution process. The two-step process is time consuming, laborious while the high temperature process is less time consuming and is recommended for SS decontamination.

  8. Characterization Testing of the Teledyne Passive Breadboard Fuel Cell Powerplant

    NASA Technical Reports Server (NTRS)

    Loyselle, Patricia; Prokopius, Kevin

    2011-01-01

    NASA's Exploration Technology Development Program (ETDP) is tasked with the development of enabling and enhancing technologies for NASA's exploration missions. As part of that initiative, the return to the Moon requires a reliable, efficient, and lightweight fuel cell powerplant system to provide power to the Altair Lunar Lander and for lunar surface systems. Fuel cell powerplants are made up of two basic parts; the fuel cell itself and the supporting ancillary subsystem. This subsystem is designed to deliver reactants to the fuel cell and remove product water and waste heat from the fuel cell. Typically, fuel cell powerplant ancillary subsystems rely upon pumps and active water separation techniques to accomplish these tasks for closed hydrogen/oxygen systems. In a typical system, these components are the largest contributors to the overall parasitic power load of the fuel cell powerplant. A potential step towards the development of an efficient lightweight power system is to maximize the use of "passive" or low-power ancillary components as a replacement to these high-power load components

  9. Passive fetal monitoring sensor

    NASA Technical Reports Server (NTRS)

    Zuckerwar, Allan J. (Inventor); Hall, Earl T. (Inventor); Baker, Donald A. (Inventor); Bryant, Timothy D. (Inventor)

    1992-01-01

    An ambulatory, passive sensor for use in a fetal monitoring system is discussed. The invention is comprised of a piezoelectric polymer film, combined with a metallic mounting plate fastened to a belt, and electrically connected to a signal processing unit by means of a shielded cable. The purpose of the sensor is to receive pressure pulses emitted by a fetus inside an expectant mother. Additionally, the monitor will filter out pressure pulses arising from other sources, such as the maternal heart.

  10. Passively actuated valve

    DOEpatents

    Modro, S. Michael; Ougouag, Abderrafi M.

    2005-09-20

    A passively actuated valve for isolating a high pressure zone from a low pressure zone and discontinuing the isolation when the pressure in the high pressure zone drops below a preset threshold. If the pressure in the high pressure zone drops below the preset threshold, the valve opens and allows flow from the high pressure zone to the low pressure zone. The valve remains open allowing pressure equalization and back-flow should a pressure inversion between the two pressure zone occur.

  11. High removal rate laser-based coating removal system

    DOEpatents

    Matthews, Dennis L.; Celliers, Peter M.; Hackel, Lloyd; Da Silva, Luiz B.; Dane, C. Brent; Mrowka, Stanley

    1999-11-16

    A compact laser system that removes surface coatings (such as paint, dirt, etc.) at a removal rate as high as 1000 ft.sup.2 /hr or more without damaging the surface. A high repetition rate laser with multiple amplification passes propagating through at least one optical amplifier is used, along with a delivery system consisting of a telescoping and articulating tube which also contains an evacuation system for simultaneously sweeping up the debris produced in the process. The amplified beam can be converted to an output beam by passively switching the polarization of at least one amplified beam. The system also has a personal safety system which protects against accidental exposures.

  12. Heat Pipe Materials Compatibility

    NASA Technical Reports Server (NTRS)

    Eninger, J. E.; Fleischman, G. L.; Luedke, E. E.

    1976-01-01

    An experimental program to evaluate noncondensable gas generation in ammonia heat pipes was completed. A total of 37 heat pipes made of aluminum, stainless steel and combinations of these materials were processed by various techniques, operated at different temperatures and tested at low temperature to quantitatively determine gas generation rates. In order of increasing stability are aluminum/stainless combination, all aluminum and all stainless heat pipes. One interesting result is the identification of intentionally introduced water in the ammonia during a reflux step as a means of surface passivation to reduce gas generation in stainless-steel/aluminum heat pipes.

  13. End-of-Mission Passivation: Successes and Challenges

    NASA Technical Reports Server (NTRS)

    Johnson, Nicholas; Matney, Mark

    2012-01-01

    The passivation of spacecraft and launch vehicle orbital stages at end-of-mission has been a principal space debris mitigation measure world-wide since the 1980 s. Space vehicle passivation includes the removal of stored energies, especially those associated with propulsion and electrical power systems. Prior to 2007 the breakup of non-functioning, non-passivated space vehicles was the major source of hazardous debris in Earth orbit. The United Nations and the Inter-Agency Space Debris Coordination Committee have both included passivation in their formal space debris mitigation guidelines. This often simple countermeasure has been adopted by many spacefaring countries and organizations and has undoubtedly prevented numerous major satellite breakups. For some existing space vehicle designs, passivation requires changes in hardware, software, and/or operational procedures. Questions about the permissible degree of passivation for both current and future space vehicles have arisen and are addressed herein. An important element to be considered is the potentially long period in which the space vehicle will remain in orbit, i.e., up to 25 years after mission termination in LEO and for centuries in orbits above LEO. Finally, the issue of passivation of space vehicles which have failed prematurely is addressed.

  14. Solar heating system

    SciTech Connect

    Larkin, W.J.

    1984-01-31

    A solar heating system is provided incorporating the flat plate collector and storage tanks substantially in the same unit and avoiding the usual reverse-siphon problems that are inherent in the nature of a passive integral system of this type by a piping system wherein heating and elevation of certain vertical components of connecting piping reverses, or almost reverses, the usual net pressure head which is responsible for creating the reverse siphon.

  15. Electrochemical-Thermal Modeling and Microscale Phase Change for Passive Internal Thermal Management of Lithium Ion Batteries

    NASA Astrophysics Data System (ADS)

    Bandhauer, Todd Matthew

    In the current investigation, a fully coupled electrochemical and thermal model for lithium-ion batteries is developed to investigate the effects of different thermal management strategies on battery performance. This work represents the first ever study of these coupled electrochemical-thermal phenomena in batteries from the electrochemical heat generation all the way to the dynamic heat removal in actual hybrid electric vehicles (HEV) drive cycles. In addition, a novel, passive internal cooling system that uses heat removal through liquid-vapor phase change is developed. The proposed cooling system passively removes heat almost isothermally with negligible thermal resistances between the heat source and cooling fluid, thereby allowing battery performance to improve unimpeded by thermal limitations. For the battery model, local electrochemical reaction rates are predicted using temperature-dependent data on a commercially available battery designed for high rates (C/LiFePO4) in a computationally efficient manner. Data were collected on this small battery (˜1 Ah) over a wide range of temperatures (10°C to 60°C), depths of discharge (0.15 Ah < DOD < 0.95 Ah), and rates (-5 A to 5 A) using two separate test facilities to maintain sufficient temperature fidelity and to discern the relative influence of reversible and irreversible heating. The results show that total volumetric heat generation is a primarily a function of current and DOD, and secondarily a function of temperature. The results also show that reversible heating is significant compared to irreversible heating, with a minimum of 7.5% of the total heat generation attributable to reversible heating at 5 A and 15°C. Additional tests show that these constant current data can be used to simulate the response of the battery to dynamic loading, which serves as the basis for the electrochemical-thermal model development. This model is then used to compare the effects of external and internal cooling on battery

  16. Solar heating and you

    SciTech Connect

    1994-08-01

    This fact sheet for use with primary school classes describes what solar collectors are and how they work, passive solar rooms, flat-plate collectors, and why one should use solar heating systems. Making a solar air heater is described step-by-step with illustrations. A resource list for both students and teachers is provided for further information.

  17. Deployable Heat Pipe Radiator

    NASA Technical Reports Server (NTRS)

    Edelstein, F.

    1975-01-01

    A 1.2- by 1.8-m variable conductance heat pipe radiator was designed, built, and tested. The radiator has deployment capability and can passively control Freon-21 fluid loop temperatures under varying loads and environments. It consists of six grooved variable conductance heat pipes attached to a 0.032-in. aluminum panel. Heat is supplied to the radiator via a fluid header or a single-fluid flexible heat pipe header. The heat pipe header is an artery design that has a flexible section capable of bending up to 90 degrees. Radiator loads as high as 850 watts were successfully tested. Over a load variation of 200 watts, the outlet temperature of the Freon-21 fluid varied by 7 F. An alternate control system was also investigated which used a variable conductance heat pipe header attached to the heat pipe radiator panel.

  18. Passive Energy Building Design Tool

    1994-11-01

    SOLAR5 is a computer aided design tool to help architects design better, more energy efficient buildings. It is intended for use at the beginning of the design process. To get started, only four pieces of information are necessary to compute the energy needed: the square footage, the number of stories, the kind of building (such as school, home, hotel, or any one of 20 types), and its location (the program stores the temperature ranges formore » fourty major cities). Additional information may be given later to fine tune the design. An expert system using heuristics from a wide range of sources, automatically creates a passive solar baseline building from the four facts specified for that project. By modifying and adapting prior designs the user can create and work upon as many as nine schemes simultaneously. SOLAR5 can analyze the buildings thermal performance for each hour of each month and plot its total heat gain or loss as a three-dimensional surface. After reading the plot, the user can immediately redesign the building and rerun the analysis. Separate heat gain/loss surfaces can be plotted for each of the different parts of the building or schemes that add together to make up the total, including walls, roof, windows, skylights, floor, slab on grade, people, lights, equipment, and infiltration. Two different schemes can be instantly compared by asking for a three-dimensional plot showing only the difference in their performances. The objective of SOLAR5 is to allow the designer to make changes easily and quickly with detailed instantaneous pictorial feedback of the implications of the change.« less

  19. Congressionally Directed Project for Passive NOx Removal Catalysts Research

    SciTech Connect

    Schneider, William

    2014-08-29

    The Recipient proposes to produce new scientific and technical knowledge and tools to enable the discovery and deployment of highly effective materials for the selective catalytic reduction (SCR) of nitrogen oxides (NOx) from lean combustion exhaust. A second goal is to demonstrate a closely coupled experimental and computational approach to heterogeneous catalysis research. These goals will be met through the completion of four primary technical objectives: First, an in-depth kinetic analysis will be performed on two prominent classes of NOx SCR catalysts, Fe- and Cu-exchanged beta and ZSM-5 zeolites, over a wide range of catalyst formulation and under identical, high conversion conditions as a function of gas phase composition. Second, the nanoscale structure and adsorption chemistry of these high temperature (HT) and low temperature (LT) catalysts will be determined using in situ and operando spectroscopy under the same reaction conditions. Third, first-principles molecular simulations will be used to model the metal-zeolite active sites, their adsorption chemistry, and key steps in catalytic function. Fourth, this information will be integrated into chemically detailed mechanistic and kinetic descriptions and models of the operation of these well- defined NOx SCR catalysts under practically relevant reaction conditions. The new knowledge and models that derive from this work will be published in the scientific literature.

  20. Fundamental studies of passivity and passivity breakdown. Final report

    SciTech Connect

    Macdonald, D.D.; Urquidi-Macdonald, M.; Song, H.; Biaggio-Rocha, S.; Searson, P.

    1991-11-01

    This report summarizes the findings of our fundamental research program on passivity and passivity breakdown. During the past three and one half years in this program (including the three year incrementally-funded grant prior to the present grant), we developed and experimentally tested various physical models for the growth and breakdown of passive films on metal surfaces. These models belong to a general class termed ``point defects models`` (PDMs), in which the growth and breakdown of passive films are described in terms of the movement of anion and cation vacancies.

  1. Stable surface passivation process for compound semiconductors

    DOEpatents

    Ashby, Carol I. H.

    2001-01-01

    A passivation process for a previously sulfided, selenided or tellurated III-V compound semiconductor surface. The concentration of undesired mid-gap surface states on a compound semiconductor surface is reduced by the formation of a near-monolayer of metal-(sulfur and/or selenium and/or tellurium)-semiconductor that is effective for long term passivation of the underlying semiconductor surface. Starting with the III-V compound semiconductor surface, any oxidation present thereon is substantially removed and the surface is then treated with sulfur, selenium or tellurium to form a near-monolayer of chalcogen-semiconductor of the surface in an oxygen-free atmosphere. This chalcogenated surface is then contacted with a solution of a metal that will form a low solubility chalcogenide to form a near-monolayer of metal-chalcogen-semiconductor. The resulting passivating layer provides long term protection for the underlying surface at or above the level achieved by a freshly chalcogenated compound semiconductor surface in an oxygen free atmosphere.

  2. Tick removal.

    PubMed

    Roupakias, S; Mitsakou, P; Nimer, A Al

    2011-03-01

    Ticks are blood feeding external parasites which can cause local and systemic complications to human body. A lot of tick-borne human diseases include Lyme disease and virus encephalitis, can be transmitted by a tick bite. Also secondary bacterial skin infection, reactive manifestations against tick allergens, and granuloma's formation can be occurred. Tick paralysis is a relatively rare complication but it can be fatal. Except the general rules for tick bite prevention, any tick found should be immediately and completely removed alive. Furthermore, the tick removal technique should not allow or provoke the escape of infective body fluids through the tick into the wound site, and disclose any local complication. Many methods of tick removal (a lot of them are unsatisfactory and/or dangerous) have been reported in the literature, but there is very limited experimental evidence to support these methods. No technique will remove completely every tick. So, there is not an appropriate and absolutely effective and/or safe tick removal technique. Regardless of the used tick removal technique, clinicians should be aware of the clinical signs of tick-transmitted diseases, the public should be informed about the risks and the prevention of tick borne diseases, and persons who have undergone tick removal should be monitored up to 30 days for signs and symptoms. PMID:21710824

  3. KKG Group Paraffin Removal

    SciTech Connect

    Schulte, Ralph

    2001-12-01

    The Rocky Mountain Oilfield Testing Center (RMOTC) has recently completed a test of a paraffin removal system developed by the KKG Group utilizing the technology of two Russian scientists, Gennady Katzyn and Boris Koggi. The system consisting of chemical ''sticks'' that generate heat in-situ to melt the paraffin deposits in oilfield tubing. The melted paraffin is then brought to the surface utilizing the naturally flowing energy of the well.

  4. Passive Solar Commercial Demonstration Program: Phase I. Final report

    SciTech Connect

    1981-02-10

    The passive solar retrofit of a small existing commercial/residential building is described. An add on gallery/sunspace is integrated into the existing structure both in terms of energy and architectural functioning. The sunspace solution maximizes the amount of south facing glass for solar heat gain, while still allowing a deep penetration of daylight into the existing buildings. (MHR)

  5. Steam turbine: Alternative emergency drive for the secure removal of residual heat from the core of light water reactors in ultimate emergency situation

    SciTech Connect

    Souza Dos Santos, R.

    2012-07-01

    In 2011 the nuclear power generation has suffered an extreme probation. That could be the meaning of what happened in Fukushima Nuclear Power Plants. In those plants, an earthquake of 8.9 on the Richter scale was recorded. The quake intensity was above the trip point of shutting down the plants. Since heat still continued to be generated, the procedure to cooling the reactor was started. One hour after the earthquake, a tsunami rocked the Fukushima shore, degrading all cooling system of plants. Since the earthquake time, the plant had lost external electricity, impacting the pumping working, drive by electric engine. When operable, the BWR plants responded the management of steam. However, the lack of electricity had degraded the plant maneuvers. In this paper we have presented a scheme to use the steam as an alternative drive to maintain operable the cooling system of nuclear power plant. This scheme adds more reliability and robustness to the cooling systems. Additionally, we purposed a solution to the cooling in case of lacking water for the condenser system. In our approach, steam driven turbines substitute electric engines in the ultimate emergency cooling system. (authors)

  6. The small heat shock protein B8 (HSPB8) confers resistance to bortezomib by promoting autophagic removal of misfolded proteins in multiple myeloma cells.

    PubMed

    Hamouda, Mohamed-Amine; Belhacene, Nathalie; Puissant, Alexandre; Colosetti, Pascal; Robert, Guillaume; Jacquel, Arnaud; Mari, Bernard; Auberger, Patrick; Luciano, Frederic

    2014-08-15

    Velcade is one of the inescapable drug to treat patient suffering from multiple myeloma (MM) and resistance to this drug represents a major drawback for patients. However, the mechanisms underlying velcade resistance remain incompletely understood. We derived several U266 MM cell clones that resist to velcade. U266-resistant cells were resistant to velcade-induced cell death but exhibited a similar sensitivity to various proapoptotic stimuli. Careful analysis of proteosomal subunits and proteasome enzymatic activities showed that neither the composition nor the activity of the proteasome was affected in velcade-resistant cells. Elimination of velcade-induced poly-ubiquitinated proteins and protein aggregates was drastically stimulated in the resistant cells and correlated with increased cell survival. Inhibition of the lysosomal activity in velcade-resistant cells resulted in an increase of cell aggregates and decrease survival, indicating that aggregates are eliminated through lysosomal degradation. In addition, pangenomic profiling of velcade-sensitive and resistant cells showed that the small heat shock protein HSPB8 was overexpressed in resistant cells. Finally, gain and loss of function experiment demonstrated that HSPB8 is a key factor for velcade resistance. In conclusion, HSPB8 plays an important role for the elimination of aggregates in velcade-resistant cells that contributes to their enhanced survival.

  7. Correction of magnetization sextupole and decapole in a 5 centimeter bore SSC dipole using passive superconductor

    SciTech Connect

    Green, M.A.

    1991-05-01

    Higher multipoles due to magnetization of the superconductor in four and five centimeter bore Superconducting Super Collider (SSC) superconducting dipole magnets have been observed. The use of passive superconductor to correct out the magnetization sextupole has been demonstrated on two dipoles built by the Lawrence Berkeley Laboratory (LBL). This reports shows how passive correction can be applied to the five centimeter SSC dipoles to remove sextupole and decapole caused by magnetization of the dipole superconductor. Two passive superconductor corrector options will be presented. The change in magnetization sextupole and decapole due to flux creep decay of the superconductor during injection can be partially compensated for using the passive superconductor. 9 refs; 5 figs.

  8. Radiation detector system having heat pipe based cooling

    DOEpatents

    Iwanczyk, Jan S.; Saveliev, Valeri D.; Barkan, Shaul

    2006-10-31

    A radiation detector system having a heat pipe based cooling. The radiation detector system includes a radiation detector thermally coupled to a thermo electric cooler (TEC). The TEC cools down the radiation detector, whereby heat is generated by the TEC. A heat removal device dissipates the heat generated by the TEC to surrounding environment. A heat pipe has a first end thermally coupled to the TEC to receive the heat generated by the TEC, and a second end thermally coupled to the heat removal device. The heat pipe transfers the heat generated by the TEC from the first end to the second end to be removed by the heat removal device.

  9. Passive bistatic radar analysis

    NASA Astrophysics Data System (ADS)

    O'Hagan, Daniel W.; Kuschel, H.; Schiller, Joachim

    2009-06-01

    Passive Bistatic Radar (PBR) research is at its zenith with several notable PBR systems currently operational, or available for deployment. Such PBRs include the Manastash Ridge Radar (MRR) developed for and by academia; Silent Sentry developed as a commercial concern by Lockheed Martin; and Homeland Alerter (HA100) also a commercial system developed by Thales. However at present, despite the existence of numerous PBR prototypes, take up of commercial passive radar technology remains slow. This is due in part to technology immaturity, in part to politics, and particularly due to the fact that monostatic radars perform so well. If PBRs are to enjoy longevity as a viable technology then it is imperative that they address certain niche application areas, with the aforementioned MRR being one prime example of this. The focus of this paper will be an analysis of a PBR system that utilised FM radio signals of opportunity to detect aircraft targets with an RCS generally not lower than 20 m2. The paper will demonstrate the theoretical detection coverage of an FM based PBR operating in a severe interference environment.

  10. Passive damping technology demonstration

    NASA Astrophysics Data System (ADS)

    Holman, Robert E.; Spencer, Susan M.; Austin, Eric M.; Johnson, Conor D.

    1995-05-01

    A Hughes Space Company study was undertaken to (1) acquire the analytical capability to design effective passive damping treatments and to predict the damped dynamic performance with reasonable accuracy; (2) demonstrate reasonable test and analysis agreement for both baseline and damped baseline hardware; and (3) achieve a 75% reduction in peak transmissibility and 50% reduction in rms random vibration response. Hughes Space Company teamed with CSA Engineering to learn how to apply passive damping technology to their products successfully in a cost-effective manner. Existing hardware was selected for the demonstration because (1) previous designs were lightly damped and had difficulty in vibration test; (2) multiple damping concepts could be investigated; (3) the finite element model, hardware, and test fixture would be available; and (4) damping devices could be easily implemented. Bracket, strut, and sandwich panel damping treatments that met the performance goals were developed by analysis. The baseline, baseline with damped bracket, and baseline with damped strut designs were built and tested. The test results were in reasonable agreement with the analytical predictions and demonstrated that the desired reduction in dynamic response could be achieved. Having successfully demonstrated this approach, it can now be used with confidence for future designs as a means for reducing weight and enhancing reliability.

  11. Volcanic passive margins

    NASA Astrophysics Data System (ADS)

    Geoffroy, Laurent

    2005-12-01

    Compared to non-volcanic ones, volcanic passive margins mark continental break-up over a hotter mantle, probably subject to small-scale convection. They present distinctive genetic and structural features. High-rate extension of the lithosphere is associated with catastrophic mantle melting responsible for the accretion of a thick igneous crust. Distinctive structural features of volcanic margins are syn-magmatic and continentward-dipping crustal faults accommodating the seaward flexure of the igneous crust. Volcanic margins present along-axis a magmatic and tectonic segmentation with wavelength similar to adjacent slow-spreading ridges. Their 3D organisation suggests a connection between loci of mantle melting at depths and zones of strain concentration within the lithosphere. Break-up would start and propagate from localized thermally-softened lithospheric zones. These 'soft points' could be localized over small-scale convection cells found at the bottom of the lithosphere, where adiabatic mantle melting would specifically occur. The particular structure of the brittle crust at volcanic passive margins could be interpreted by active and sudden oceanward flow of both the unstable hot mantle and the ductile part of the lithosphere during the break-up stage. To cite this article: L. Geoffroy, C. R. Geoscience 337 (2005).

  12. SBWR design update: Passively safe, nuclear power generation for the twenty first century

    SciTech Connect

    Upton, H.A.; Torbeck, J.E.; Billig, P.F.; Duncan, J.D.; Herzog, M.

    1996-07-01

    This paper describes the current state of design, development and testing of a new generation of Boiling Water Reactors, the SBWR. The SBWR is a plant that will be significantly simpler to build, operate and maintain compared to operating plants. In this paper, the design and performance of the reference 670 MWe SBWR is summarized, the economics of SBWR power generation is addressed and the current developments in component testing and integrated system testing are given. This paper specifically discusses the current innovations and key reference design features of the SBWR including the RPV, depressurization system, pressure suppression system, flammability control system (based on passive autocatalytic recombiners), gravity driven cooling system, the passive containment cooling system, isolation condenser system and other unique engineered safety features that rely on gravity or stored energy to ensure core cooling, decay heat removal, and ATWS mitigation. The component and integrated system development testing summarized includes key results of recently concluded PANTHERS condenser tests conducted at SIET in Italy, GIRAFFE non-condensable gas testing by Toshiba in Japan, and the ongoing testing at the PANDA facility at PSI in Switzerland.

  13. Heat transfer system

    DOEpatents

    McGuire, Joseph C.

    1982-01-01

    A heat transfer system for a nuclear reactor. Heat transfer is accomplished within a sealed vapor chamber which is substantially evacuated prior to use. A heat transfer medium, which is liquid at the design operating temperatures, transfers heat from tubes interposed in the reactor primary loop to spaced tubes connected to a steam line for power generation purposes. Heat transfer is accomplished by a two-phase liquid-vapor-liquid process as used in heat pipes. Condensible gases are removed from the vapor chamber through a vertical extension in open communication with the chamber interior.

  14. Heat transfer system

    DOEpatents

    Not Available

    1980-03-07

    A heat transfer system for a nuclear reactor is described. Heat transfer is accomplished within a sealed vapor chamber which is substantially evacuated prior to use. A heat transfer medium, which is liquid at the design operating temperatures, transfers heat from tubes interposed in the reactor primary loop to spaced tubes connected to a steam line for power generation purposes. Heat transfer is accomplished by a two-phase liquid-vapor-liquid process as used in heat pipes. Condensible gases are removed from the vapor chamber through a vertical extension in open communication with the chamber interior.

  15. Passive-solar construction handbook

    SciTech Connect

    Levy, E.; Evans, D.; Gardstein, C.

    1981-02-01

    Many of the basic elements of passive solar design are reviewed. Passive solar construction is covered according to system type, each system type discussion including a general discussion of the important design and construction issues which apply to the particular system and case studies illustrating designed and built examples of the system type. The three basic types of passive solar systems discussed are direct gain, thermal storage wall, and attached sunspace. Thermal performance and construction information is presented for typical materials used in passive solar collector components, storage components, and control components. Appended are an overview of analysis methods and a technique for estimating performance. (LEW)

  16. Tick removal

    MedlinePlus

    ... are small, insect-like creatures that live in woods and fields. They attach to you as you ... your clothes and skin often while in the woods. After returning home: Remove your clothes. Look closely ...

  17. Tattoo removal.

    PubMed

    Adatto, Maurice A; Halachmi, Shlomit; Lapidoth, Moshe

    2011-01-01

    Over 50,000 new tattoos are placed each year in the United States. Studies estimate that 24% of American college students have tattoos and 10% of male American adults have a tattoo. The rising popularity of tattoos has spurred a corresponding increase in tattoo removal. Not all tattoos are placed intentionally or for aesthetic reasons though. Traumatic tattoos due to unintentional penetration of exogenous pigments can also occur, as well as the placement of medical tattoos to mark treatment boundaries, for example in radiation therapy. Protocols for tattoo removal have evolved over history. The first evidence of tattoo removal attempts was found in Egyptian mummies, dated to have lived 4,000 years BC. Ancient Greek writings describe tattoo removal with salt abrasion or with a paste containing cloves of white garlic mixed with Alexandrian cantharidin. With the advent of Q-switched lasers in the late 1960s, the outcomes of tattoo removal changed radically. In addition to their selective absorption by the pigment, the extremely short pulse duration of Q-switched lasers has made them the gold standard for tattoo removal.

  18. Tattoo removal.

    PubMed

    Adatto, Maurice A; Halachmi, Shlomit; Lapidoth, Moshe

    2011-01-01

    Over 50,000 new tattoos are placed each year in the United States. Studies estimate that 24% of American college students have tattoos and 10% of male American adults have a tattoo. The rising popularity of tattoos has spurred a corresponding increase in tattoo removal. Not all tattoos are placed intentionally or for aesthetic reasons though. Traumatic tattoos due to unintentional penetration of exogenous pigments can also occur, as well as the placement of medical tattoos to mark treatment boundaries, for example in radiation therapy. Protocols for tattoo removal have evolved over history. The first evidence of tattoo removal attempts was found in Egyptian mummies, dated to have lived 4,000 years BC. Ancient Greek writings describe tattoo removal with salt abrasion or with a paste containing cloves of white garlic mixed with Alexandrian cantharidin. With the advent of Q-switched lasers in the late 1960s, the outcomes of tattoo removal changed radically. In addition to their selective absorption by the pigment, the extremely short pulse duration of Q-switched lasers has made them the gold standard for tattoo removal. PMID:21865802

  19. High-power passive-cooled diode laser device

    NASA Astrophysics Data System (ADS)

    Bonati, Guido F.; Hennig, Petra; Rollig, Ullrich; Lorenzen, Dirk

    2003-06-01

    In order to achieve a thermally stable diode laser system based on high power diode laser bars, actively cooled heatsinks in form of micro channel heat sinks (MCHS) are used to face the power loss density of 106 W/m2 while requiring a minimum device volume. At identical junction temperature, passively cooled diode lasers are usually lower in power and the device volume is much higher due to the heat flux spreading design of passive heatsinks. However, as a matter of principle, the cooling with MCHS sinks requires a sealing between the heat sink itself and the system around. This sealing is usually achieved by o-rings, what can never avoid the transfer of vapor from the cooling system into the vicinity of the diode laser. Extreme requirements on availability, which lead to corresponding lifetime requirements, like in telecom applications, already require passively cooled diode lasers without any water in the inner system boundaries. For applications not requiring the extreme compact design volume of actively cooled diode lasers but requiring extreme lifetime or a minimum outlay on the periphery, we started looking into passively cooled diode laser stacks. To achieve a minimized temperature rise in the junction, we already developed a new copper-based heat sink, spreading the power loss in an optimized manner. Based on this heatsink, we started developing a heat exchanger with a low thermal resistance while keeping the water out of the inner system boundaries. The thermal resistance is low enough to run up to 12 passively cooled diode lasers on a low ambient temperature with a minimum of periphery requirements.

  20. Incorporation of Passive Safety Systems in the Generation-IV Multi-Application Small Light Water Reactor (MASLWR)

    SciTech Connect

    Modro, S. Michael; Ougouag, Abderrafi M.; Fisher, James; Weaver, Kevan

    2002-07-01

    The Idaho National Engineering and Environmental Laboratory (INEEL), Nexant Inc. and the Oregon State University (OSU) developed an innovative Multi-Application Small Light Water Reactor (MASLWR) concept. The MASLWR is a small, modular, safe, and economic natural circulation light water reactor developed with the primary goal of producing electric power, but with the flexibility to be used for water desalination or district heating with deployment in a variety of locations. The MASLWR was developed, by design, to be a safe and economic reactor concept that can be deployed in the near term by utilizing current experience and capabilities of the industry. The key features of the MASLWR concept are the extreme simplicity of the design and its passive safety systems. This paper provides an overview of safety analyses performed for the MASLWR concept and explores potential for the increase in passive safety via the implementation of new features. The results of these safety studies demonstrate that the reactor core will be provided with a stable cooling source adequate to remove decay heat without significant cladding heatup under all credible scenarios. The response of the system to accident conditions is a controlled depressurization, whereby most of the primary system blowdown occurs via the submerged ADS blowdown pathway. (authors)

  1. Impact of Passive Safety on FHR Instrumentation Systems Design and Classification

    SciTech Connect

    Holcomb, David Eugene

    2015-01-01

    Fluoride salt-cooled high-temperature reactors (FHRs) will rely more extensively on passive safety than earlier reactor classes. 10CFR50 Appendix A, General Design Criteria for Nuclear Power Plants, establishes minimum design requirements to provide reasonable assurance of adequate safety. 10CFR50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors, provides guidance on how the safety significance of systems, structures, and components (SSCs) should be reflected in their regulatory treatment. The Nuclear Energy Institute (NEI) has provided 10 CFR 50.69 SSC Categorization Guideline (NEI-00-04) that factors in probabilistic risk assessment (PRA) model insights, as well as deterministic insights, through an integrated decision-making panel. Employing the PRA to inform deterministic requirements enables an appropriately balanced, technically sound categorization to be established. No FHR currently has an adequate PRA or set of design basis accidents to enable establishing the safety classification of its SSCs. While all SSCs used to comply with the general design criteria (GDCs) will be safety related, the intent is to limit the instrumentation risk significance through effective design and reliance on inherent passive safety characteristics. For example, FHRs have no safety-significant temperature threshold phenomena, thus enabling the primary and reserve reactivity control systems required by GDC 26 to be passively, thermally triggered at temperatures well below those for which core or primary coolant boundary damage would occur. Moreover, the passive thermal triggering of the primary and reserve shutdown systems may relegate the control rod drive motors to the control system, substantially decreasing the amount of safety-significant wiring needed. Similarly, FHR decay heat removal systems are intended to be running continuously to minimize the amount of safety-significant instrumentation needed to initiate

  2. Heating/daylighting prototype development. Phase I, Passive and Hybrid Solar Manufactured Building Project. Interim report and project status report No. 1, 1 October 1979-29 February 1980

    SciTech Connect

    Snyder, M.; Fraker, H.; Lindsey, L.; Braham, W.; Hallagan, W.; Huffman, J.

    1980-03-31

    Climatological data, both representative (typical) and extreme conditions, relevant to building energy use in Grandview, Missouri are presented. The energy-related characteristics of a particular building and its use are merged with ambient weather conditions. The graphs depict daily fluctuations in the major categories of building heating/cooling load for the experimental building (Roof Runner facility) at Butler Research Center. Data input include hourly weather and building occupancy schedules, the geometry and fixed thermal characteristics (component R-values, heat capacities, etc.) of the prototype structure, and variable conditions (status of moveable insulating shutters, HVAC operating modes, etc.). The prototype systems to be incorporated in the new Roof Runner building are shown. Both warehouse (no ceiling) and office (suspended ceiling) system types are included. The diagrams conceptually depict the heat flows in several representative operating modes, sampling the wide variety of operating conditions which will be evaluated during the testing phase of this project. Cost estimates for the designs selected for construction are provided. (MHR)

  3. Hydrophobic liquid/gas separator for heat pipes

    NASA Technical Reports Server (NTRS)

    Marcus, B. D.

    1972-01-01

    Perforated nonwetting plug of material such as polytetrafluoroethylene is mounted in gas reservoir feed tube, preferably at end which extends into heat pipe condenser section, to prevent liquid from entering gas reservoir of passively controlled heat pipe.

  4. Detroit Edison's Fermi 1 - Preparation for Reactor Removal

    SciTech Connect

    Swindle, Danny

    2008-01-15

    This paper is intended to provide information about the ongoing decommissioning tasks at Detroit Edison's Fermi 1 plant, and in particular, the work being performed to prepare the reactor for removal and disposal. In 1972 Fermi 1 was shutdown and the fuel returned to the Atomic Energy Commission. By the end of 1975, a retirement plan was prepared, the bulk sodium removed, and the plant placed in a safe store condition. The plant systems were left isolated with the sodium containing systems inert with carbon dioxide in an attempt to form a carbonate layer, thus passivating the underlying reactive sodium. In 1996, Detroit Edison determined to evaluate the condition of the plant and to make recommendations in relation to the Fermi 1 future plans. At the end of 1997 approval was obtained to remove the bulk asbestos and residual alkali-metals (i.e., sodium and sodium potassium (NaK)). In 2000, full nuclear decommissioning of the plant was approved. To date, the bulk asbestos insulation has been removed, and the only NaK remaining is located in six capillary instrument tubes. The remaining sodium is contained within the reactor, two of the three primary loops, and miscellaneous removed pipes and equipment to be processed. The preferred method for removing or reacting sodium at Fermi 1 is by injecting superheated steam into a heated, nitrogen inert system. The byproducts of this reaction are caustic sodium hydroxide, hydrogen gas, and heat. The decision was made to separate the three primary loops from the reactor for better control prior to processing each loop and the reactor separately. The first loop has already been processed. The main focus is now to process the reactor to allow removal and disposal of the Class C waste prior to the anticipated June 2008 closure of the Barnwell radioactive waste disposal facility located in South Carolina. Lessons learnt are summarized and concern: the realistic schedule and adherence to the schedule, time estimates, personnel

  5. Adaptive passive fathometer processing.

    PubMed

    Siderius, Martin; Song, Heechun; Gerstoft, Peter; Hodgkiss, William S; Hursky, Paul; Harrison, Chris

    2010-04-01

    Recently, a technique has been developed to image seabed layers using the ocean ambient noise field as the sound source. This so called passive fathometer technique exploits the naturally occurring acoustic sounds generated on the sea-surface, primarily from breaking waves. The method is based on the cross-correlation of noise from the ocean surface with its echo from the seabed, which recovers travel times to significant seabed reflectors. To limit averaging time and make this practical, beamforming is used with a vertical array of hydrophones to reduce interference from horizontally propagating noise. The initial development used conventional beamforming, but significant improvements have been realized using adaptive techniques. In this paper, adaptive methods for this process are described and applied to several data sets to demonstrate improvements possible as compared to conventional processing.

  6. Passive containment cooling system

    DOEpatents

    Billig, Paul F.; Cooke, Franklin E.; Fitch, James R.

    1994-01-01

    A passive containment cooling system includes a containment vessel surrounding a reactor pressure vessel and defining a drywell therein containing a non-condensable gas. An enclosed wetwell pool is disposed inside the containment vessel, and a gravity driven cooling system (GDCS) pool is disposed above the wetwell pool in the containment vessel and is vented to the drywell. An isolation pool is disposed above the GDCS pool and includes an isolation condenser therein. The condenser has an inlet line disposed in flow communication with the drywell for receiving the non-condensable gas along with any steam released therein following a loss-of-coolant accident (LOCA). The condenser also has an outlet line disposed in flow communication with the drywell for returning to the drywell both liquid condensate produced upon cooling of the steam and the non-condensable gas for reducing pressure within the containment vessel following the LOCA.

  7. Passive Ball Capture Joint

    NASA Technical Reports Server (NTRS)

    Cloyd, Richard A. (Inventor); Bryan, Thomas C. (Inventor)

    2003-01-01

    A passive ball capture joint has a sleeve with a plurality of bores distributed about a circumference thereof and formed therethrough at an acute angle relative to the sleeve's longitudinal axis. A spring-loaded retainer is slidingly fitted in each bore and is biased such that, if allowed, will extend at least partially into the sleeve to retain a ball therein. A ring, rotatably mounted about the bores, has an interior wall defining a plurality of shaped races that bear against the spring-loaded retainers. A mechanized rotational force producer is coupled to the ring. The ring can be rotated from a first position (that presses the retainers into the sleeve to lock the ball in place) to a second position (that allows the retainers to springback out of the sleeve to release the ball).

  8. Passive containment cooling system

    DOEpatents

    Billig, P.F.; Cooke, F.E.; Fitch, J.R.

    1994-01-25

    A passive containment cooling system includes a containment vessel surrounding a reactor pressure vessel and defining a drywell therein containing a non-condensable gas. An enclosed wetwell pool is disposed inside the containment vessel, and a gravity driven cooling system (GDCS) pool is disposed above the wetwell pool in the containment vessel and is vented to the drywell. An isolation pool is disposed above the GDCS pool and includes an isolation condenser therein. The condenser has an inlet line disposed in flow communication with the drywell for receiving the non-condensable gas along with any steam released therein following a loss-of-coolant accident (LOCA). The condenser also has an outlet line disposed in flow communication with the drywell for returning to the drywell both liquid condensate produced upon cooling of the steam and the non-condensable gas for reducing pressure within the containment vessel following the LOCA. 1 figure.

  9. Passive focus sensor

    NASA Astrophysics Data System (ADS)

    Engelhardt, Kai; Knop, Karl

    1995-05-01

    A focus-sensor module that could take the place of the visual-image control for professional large-format cameras was fabricated. In addition, a passive focus-sensing method was shown to work at arbitrary locations and orientations in the recording plane of large-format professional cameras. A focus resolution of better than 0.1 mm and a range of measurement of +/- 5 mm at the image side were obtained at a minimum level of illuminance and with an aperture f/5.6 of the imaging lens. In the current method, three out of four images that arose from various sections of the camera's objective lens were applied for triangulation. The demonstrated approach was based on a linear photodiode array and employed one-dimensional image information for focus sensing.

  10. Passive magnetic bearing system

    SciTech Connect

    Post, Richard F.

    2014-09-02

    An axial stabilizer for the rotor of a magnetic bearing provides external control of stiffness through switching in external inductances. External control also allows the stabilizer to become a part of a passive/active magnetic bearing system that requires no external source of power and no position sensor. Stabilizers for displacements transverse to the axis of rotation are provided that require only a single cylindrical Halbach array in its operation, and thus are especially suited for use in high rotation speed applications, such as flywheel energy storage systems. The elimination of the need of an inner cylindrical array solves the difficult mechanical problem of supplying support against centrifugal forces for the magnets of that array. Compensation is provided for the temperature variation of the strength of the magnetic fields of the permanent magnets in the levitating magnet arrays.

  11. Commentary on "Capturing the Evasive Passive"

    ERIC Educational Resources Information Center

    Lillo-Martin, Diane; Snyder, William

    2009-01-01

    Passives has been the focus of much research in language acquisition since the 1970s. It has been clear from this research that young children seldom produce passives spontaneously, particularly "long" or "full" passives with a by-phrase; and they usually perform poorly on experimental tests of the comprehension of passives, especially passives of…

  12. Advanced Coating Removal Techniques

    NASA Technical Reports Server (NTRS)

    Seibert, Jon

    2006-01-01

    An important step in the repair and protection against corrosion damage is the safe removal of the oxidation and protective coatings without further damaging the integrity of the substrate. Two such methods that are proving to be safe and effective in this task are liquid nitrogen and laser removal operations. Laser technology used for the removal of protective coatings is currently being researched and implemented in various areas of the aerospace industry. Delivering thousands of focused energy pulses, the laser ablates the coating surface by heating and dissolving the material applied to the substrate. The metal substrate will reflect the laser and redirect the energy to any remaining protective coating, thus preventing any collateral damage the substrate may suffer throughout the process. Liquid nitrogen jets are comparable to blasting with an ultra high-pressure water jet but without the residual liquid that requires collection and removal .As the liquid nitrogen reaches the surface it is transformed into gaseous nitrogen and reenters the atmosphere without any contamination to surrounding hardware. These innovative technologies simplify corrosion repair by eliminating hazardous chemicals and repetitive manual labor from the coating removal process. One very significant advantage is the reduction of particulate contamination exposure to personnel. With the removal of coatings adjacent to sensitive flight hardware, a benefit of each technique for the space program is that no contamination such as beads, water, or sanding residue is left behind when the job is finished. One primary concern is the safe removal of coatings from thin aluminum honeycomb face sheet. NASA recently conducted thermal testing on liquid nitrogen systems and found that no damage occurred on 1/6", aluminum substrates. Wright Patterson Air Force Base in conjunction with Boeing and NASA is currently testing the laser remOval technique for process qualification. Other applications of liquid

  13. Cooperative passive-solar commercial retrofit

    NASA Astrophysics Data System (ADS)

    Brown, W. T.

    1982-12-01

    The primary objectives of this project were: the conversion of an existing south-facing storefront into a trombe'-wall passive solar collector, the sharing of information on simple low-cost energy alternatives with the local community, and the reduction of the store building's dependence on non-renewable fossil fuel for space heating. Six 6' wide pre-assembled collector glazing panels were mounted on a 12' high by 36' long portion of the south-facing masonry wall. Vent-holes were cut through the wall at each panel to provide air inlets and outlets for the collector and monitoring equipment was installed to record performance. A series of hands-on construction workshops were attended by Co-op and community members. During these sessions, collector components were assembled. The panels were installed on April 22, 1981 in celebration of Earth Day. Additional sessions were held to complete the project, make necessary modifications and install sensors. Project personnel participated in several energy-education activities, including workshops, seminars and alternative energy home tours. A community-based energy resource council was founded with the assistance of several key Co-op project members and a fully-illustrated How-To manual, entitled Passive Solar Collector: A Trombe'-Wall Retrofit Guide was published. Finally, a variety of energy conservation measures were undertaken. These included a new airlock store entry, insulated store ceiling, destratification ceiling fans and wood-burning furnaces have combined with the passive solar collector to substantially reduce the use of fuel oil for heat.

  14. Simulation of a passive solar energy system. Master's thesis

    SciTech Connect

    Slate, M.P.

    1982-12-01

    A simple lumped capacitance-resistance model is used to simulate heat flow in a residential size structure heated passively by the sun. The model takes the form of an analogous electrical circuit. A computer program was written to analyse the circuit. By altering the input parameters of the program, the thermal performance of a wide variety of passive solar designs can be investigated for any geographical location. By comparing program generated data to data taken from experimental test cells in Los Alamos, New Mexico, it was found that the simulation program predicted energy use to within 4 percent of measured values. Also, the computer program predicted temperature swings to within 16 percent of measured swings. Correlation with empirical methods of calculating monthly and annual savings in fuel use for heating was poor. Using the simulation calculations as a base, the predictions of anual savings differed by as much as 76 percent.

  15. Hood River Passive House, Hood River, Oregon (Fact Sheet)

    SciTech Connect

    Not Available

    2014-02-01

    The Hood River Passive Project was developed by Root Design Build of Hood River Oregon using the Passive House Planning Package (PHPP) to meet all of the requirements for certification under the European Passive House standards. The Passive House design approach has been gaining momentum among residential designers for custom homes and BEopt modeling indicates that these designs may actually exceed the goal of the U.S. Department of Energy's (DOE) Building America program to "reduce home energy use by 30%-50%" (compared to 2009 energy codes for new homes). This report documents the short term test results of the Shift House and compares the results of PHPP and BEopt modeling of the project. The design includes high R-Value assemblies, extremely tight construction, high performance doors and windows, solar thermal DHW, heat recovery ventilation, moveable external shutters and a high performance ductless mini-split heat pump. Cost analysis indicates that many of the measures implemented in this project did not meet the BA standard for cost neutrality. The ductless mini-split heat pump, lighting and advanced air leakage control were the most cost effective measures. The future challenge will be to value engineer the performance levels indicated here in modeling using production based practices at a significantly lower cost.

  16. Flow and heat transfer enhancement in tube heat exchangers

    NASA Astrophysics Data System (ADS)

    Sayed Ahmed, Sayed Ahmed E.; Mesalhy, Osama M.; Abdelatief, Mohamed A.

    2015-11-01

    The performance of heat exchangers can be improved to perform a certain heat-transfer duty by heat transfer enhancement techniques. Enhancement techniques can be divided into two categories: passive and active. Active methods require external power, such as electric or acoustic field, mechanical devices, or surface vibration, whereas passive methods do not require external power but make use of a special surface geometry or fluid additive which cause heat transfer enhancement. The majority of commercially interesting enhancement techniques are passive ones. This paper presents a review of published works on the characteristics of heat transfer and flow in finned tube heat exchangers of the existing patterns. The review considers plain, louvered, slit, wavy, annular, longitudinal, and serrated fins. This review can be indicated by the status of the research in this area which is important. The comparison of finned tubes heat exchangers shows that those with slit, plain, and wavy finned tubes have the highest values of area goodness factor while the heat exchanger with annular fin shows the lowest. A better heat transfer coefficient ha is found for a heat exchanger with louvered finned and thus should be regarded as the most efficient one, at fixed pumping power per heat transfer area. This study points out that although numerous studies have been conducted on the characteristics of flow and heat transfer in round, elliptical, and flat tubes, studies on some types of streamlined-tubes shapes are limited, especially on wing-shaped tubes (Sayed Ahmed et al. in Heat Mass Transf 50: 1091-1102, 2014; in Heat Mass Transf 51: 1001-1016, 2015). It is recommended that further detailed studies via numerical simulations and/or experimental investigations should be carried out, in the future, to put further insight to these fin designs.

  17. Assessment of thermal performance for the design of a passively-cooled plutonium storage vault

    NASA Astrophysics Data System (ADS)

    Sanders, Joseph Conway

    A passively-cooled plutonium storage vault, rather than one with a safety-qualified, forced-flow cooling system, could save as much as 100 million over the project lifetime. Either configuration must maintain the temperature of the stored plutonium metal, with its significant internal heat generation, below 239 sp circF. Alpha-phase metal, if allowed to exceed this temperature, will transition to beta-phase metal and undergo a volumetric expansion which could rupture the storage container system. An investigation was performed to determine whether a passively-cooled vault is feasible. Significant temperature drops occurred in two regions, both were gas-filled vertical annuli with heat flux boundary conditions on the inner surfaces and fixed temperature boundary conditions on the outer surfaces. The thermal resistance method was employed to evaluate radial heat transfer across each annulus, coupling natural convection, radiation, and conduction. Correlations from Thomas et al and Kulacki et al were used to evaluate the degree of natural convective enhancement. For the helium-filled region between the plutonium metal rod and the container with a characteristic length of 3.9 centimeters and an aspect ratio of 5.6, the Rayleigh number was 800 when the effect of radiation was removed. This resulted in a Nusselt number of 1.8. For the air-filled region between twelve vertically arranged containers and the storage tube with a characteristic length of 5.8 centimeters and an aspect ratio of 78, the Rayleigh number was 5times10sp5. This resulted in a Nusselt number of approximately 4.5, neglecting the effect of radiation. FIDAP 7.62\\copyright$ (Fluid Dynamics Analysis Package) was used to perform multi-dimensional finite element analyses of these regions employing both buoyant and radiative effects. Both simplified and more geometrically complex models were employed, all of which compared favorably to the results using the thermal resistance method. The results of the

  18. Design of Complex Systems to Achieve Passive Safety: Natural Circulation Cooling of Liquid Salt Pebble Bed Reactors

    NASA Astrophysics Data System (ADS)

    Scarlat, Raluca Olga

    This dissertation treats system design, modeling of transient system response, and characterization of individual phenomena and demonstrates a framework for integration of these three activities early in the design process of a complex engineered system. A system analysis framework for prioritization of experiments, modeling, and development of detailed design is proposed. Two fundamental topics in thermal-hydraulics are discussed, which illustrate the integration of modeling and experimentation with nuclear reactor design and safety analysis: thermal-hydraulic modeling of heat generating pebble bed cores, and scaled experiments for natural circulation heat removal with Boussinesq liquids. The case studies used in this dissertation are derived from the design and safety analysis of a pebble bed fluoride salt cooled high temperature nuclear reactor (PB-FHR), currently under development in the United States at the university and national laboratories level. In the context of the phenomena identification and ranking table (PIRT) methodology, new tools and approaches are proposed and demonstrated here, which are specifically relevant to technology in the early stages of development, and to analysis of passive safety features. A system decomposition approach is proposed. Definition of system functional requirements complements identification and compilation of the current knowledge base for the behavior of the system. Two new graphical tools are developed for ranking of phenomena importance: a phenomena ranking map, and a phenomena identification and ranking matrix (PIRM). The functional requirements established through this methodology were used for the design and optimization of the reactor core, and for the transient analysis and design of the passive natural circulation driven decay heat removal system for the PB-FHR. A numerical modeling approach for heat-generating porous media, with multi-dimensional fluid flow is presented. The application of this modeling

  19. Use of a temperature-initiated passive cooling system (TIPACS) for the modular high-temperature gas-cooled reactor cavity cooling system (RCCS)

    SciTech Connect

    Forsberg, C.W.; Conklin, J.; Reich, W.J.

    1994-04-01

    A new type of passive cooling system has been invented (Forsberg 1993): the Temperature-Initiated Passive Cooling System (TIPACS). The characteristics of the TIPACS potentially match requirements for an improved reactor-cavity-cooling system (RCCS) for the modular high-temperature gas-cooled reactor (MHTGR). This report is an initial evaluation of the TIPACS for the MHTGR with a Rankines (steam) power conversion cycle. Limited evaluations were made of applying the TIPACS to MHTGRs with reactor pressure vessel temperatures up to 450 C. These temperatures may occur in designs of Brayton cycle (gas turbine) and process heat MHTGRs. The report is structured as follows. Section 2 describes the containment cooling issues associated with the MHTGR and the requirements for such a cooling system. Section 3 describes TIPACS in nonmathematical terms. Section 4 describes TIPACS`s heat-removal capabilities. Section 5 analyzes the operation of the temperature-control mechanism that determines under what conditions the TIPACS rejects heat to the environment. Section 6 addresses other design and operational issues. Section 7 identifies uncertainties, and Section 8 provides conclusions. The appendixes provide the detailed data and models used in the analysis.

  20. Absorption heat pump system

    DOEpatents

    Grossman, Gershon; Perez-Blanco, Horacio

    1984-01-01

    An improvement in an absorption heat pump cycle is obtained by adding adiabatic absorption and desorption steps to the absorber and desorber of the system. The adiabatic processes make it possible to obtain the highest temperature in the absorber before any heat is removed from it and the lowest temperature in the desorber before heat is added to it, allowing for efficient utilization of the thermodynamic availability of the heat supply stream. The improved system can operate with a larger difference between high and low working fluid concentrations, less circulation losses, and more efficient heat exchange than a conventional system.

  1. Passive blast pressure sensor

    DOEpatents

    King, Michael J.; Sanchez, Roberto J.; Moss, William C.

    2013-03-19

    A passive blast pressure sensor for detecting blast overpressures of at least a predetermined minimum threshold pressure. The blast pressure sensor includes a piston-cylinder arrangement with one end of the piston having a detection surface exposed to a blast event monitored medium through one end of the cylinder and the other end of the piston having a striker surface positioned to impact a contact stress sensitive film that is positioned against a strike surface of a rigid body, such as a backing plate. The contact stress sensitive film is of a type which changes color in response to at least a predetermined minimum contact stress which is defined as a product of the predetermined minimum threshold pressure and an amplification factor of the piston. In this manner, a color change in the film arising from impact of the piston accelerated by a blast event provides visual indication that a blast overpressure encountered from the blast event was not less than the predetermined minimum threshold pressure.

  2. New passive helicopter detector

    SciTech Connect

    Elliott, G.R.

    1985-01-01

    Sandia has developed a new helicopter detector. The device relies on the correlation between the acoustic wave from the helicopter and the resulting coupled seismic wave. A significant feature of this approach is that the detector is completely passive; there is no radio frequency radiation. Intended for deployment as a perimeter sensor around a site, the unit offers a low nuisance/false alarm rate and a high probability of detection for a wide range of helicopters. Reliable detection occurs when the target is at high altitude and also very near the earth's surface. Detection ranges start at one kilometer for the small, four-place, civilian helicopter and approach five kilometers for heavier, military types. The system has two parts: a transducer package containing a microphone and a geophone and a digital processor. Development is underway for a model which will be AC powered and well suited to permanent facilities. A prototype unit using a lightweight, battery powered processor is being constructed for rapid-deployment applications. 6 figs.

  3. Passive Acoustic Vessel Localization

    NASA Astrophysics Data System (ADS)

    Suwal, Pasang Sherpa

    This thesis investigates the development of a low-cost passive acoustic system for localizing moving vessels to monitor areas where human activities such as fishing, snorkeling and poaching are restricted. The system uses several off-the-shelf sensors with unsynchronized clocks where the Time Difference of Arrival (TDOA) or time delay is extracted by cross-correlation of the signal between paired sensors. The cross-correlation function uses phase correlation or Phase Transform (PHAT) which whitens the cross-spectrum in order to de-emphasize dominant frequency components. Using the locations of pairs of sensors as foci, hyperbolic equations can be defined using the time delay between them. With three or more sensors, multiple hyperbolic functions can be calculated which intersect at a unique point: the boat's location. It is also found that increasing separation distances between sensors decreased the correlation between the signals. However larger separation distances have better localization capability than with small distances. Experimental results from the Columbia and Willamette Rivers are presented to demonstrate performance.

  4. Combining passive thermography and acoustic emission for large area fatigue damage growth assessment of a composite structure

    NASA Astrophysics Data System (ADS)

    Zalameda, Joseph N.; Horne, Michael R.; Madaras, Eric I.; Burke, Eric R.

    2016-05-01

    Passive thermography and acoustic emission data were obtained for improved real time damage detection during fatigue loading. A strong positive correlation was demonstrated between acoustic energy event location and thermal heating, especially if the structure under load was nearing ultimate failure. An image processing routine was developed to map the acoustic emission data onto the thermal imagery. This required removing optical barrel distortion and angular rotation from the thermal data. The acoustic emission data were then mapped onto thermal data, revealing the cluster of acoustic emission event locations around the thermal signatures of interest. By combining both techniques, progression of damage growth is confirmed and areas of failure are identified. This technology provides improved real time inspections of advanced composite structures during fatigue testing.

  5. Comparison of active cooling devices to passive cooling for rehabilitation of firefighters performing exercise in thermal protective clothing: A report from the Fireground Rehab Evaluation (FIRE) trial

    PubMed Central

    Hostler, David; Reis, Steven E; Bednez, James C; Kerin, Sarah; Suyama, Joe

    2010-01-01

    Background Thermal protective clothing (TPC) worn by firefighters provides considerable protection from the external environment during structural fire suppression. However, TPC is associated with physiological derangements that may have adverse cardiovascular consequences. These derangements should be treated during on-scene rehabilitation periods. Objective The present study examined heart rate and core temperature responses during the application of four active cooling devices, currently being marketed to the fire service for on-scene rehab, and compared them to passive cooling in a moderate temperature (approximately 24°C) and to an infusion of cold (4°C) saline. Methods Subjects exercised in TPC in a heated room. Following an initial exercise period (BOUT 1) the subjects exited the room, removed TPC, and for 20 minutes cooled passively at room temperature, received an infusion of cold normal saline, or were cooled by one of four devices (fan, forearm immersion in water, hand cooling, water perfused cooling vest). After cooling, subjects donned TPC and entered the heated room for another 50-minute exercise period (BOUT 2). Results Subjects were not able to fully recover core temperature during a 20-minute rehab period when provided rehydration and the opportunity to completely remove TPC. Exercise duration was shorter during BOUT 2 when compared to BOUT 1 but did not differ by cooling intervention. The overall magnitude and rate of cooling and heart rate recovery did not differ by intervention. Conclusions No clear advantage was identified when active cooling devices and cold intravenous saline were compared to passive cooling in a moderate temperature after treadmill exercise in TPC. PMID:20397868

  6. Polyurethane foam (PUF) passive samplers for monitoring phenanthrene in stormwater.

    PubMed

    Dou, Yueqin; Zhang, Tian C; Zeng, Jing; Stansbury, John; Moussavi, Massoum; Richter-Egger, Dana L; Klein, Mitchell R

    2016-04-01

    Pollution from highway stormwater runoff has been an increasing area of concern. Many structural Best Management Practices (BMPs) have been implemented for stormwater treatment and management. One challenge for these BMPs is to sample stormwater and monitor BMP performance. The main objective of this study was to evaluate the feasibility of using polyurethane foam (PUF) passive samplers (PSs) for sampling phenanthrene (PHE) in highway stormwater runoff and BMPs. Tests were conducted using batch reactors, glass-tube columns, and laboratory-scale BMPs (bioretention cells). Results indicate that sorption for PHE by PUF is mainly linearly relative to time, and the high sorption capacity allows the PUF passive sampler to monitor stormwater events for months or years. The PUF passive samplers could be embedded in BMPs for monitoring influent and effluent PHE concentrations. Models developed to link the results of batch and column tests proved to be useful for determining removal or sorption parameters and performance of the PUF-PSs. The predicted removal efficiencies of BMPs were close to the real values obtained from the control columns with errors ranging between -8.46 and 1.52%. This research showed that it is possible to use PUF passive samplers for sampling stormwater and monitoring the performance of stormwater BMPs, which warrants the field-scale feasibility studies in the future. PMID:26942631

  7. Enhancements for passive vapor extraction: The Hanford study

    SciTech Connect

    Ellerd, M.G.; Massmann, J.W.; Schwaegler, D.P.; Rohay, V.J.

    1999-05-01

    Passive vapor extraction involves wells that are screened in the unsaturated zone and open to the atmosphere. Gas will flow out of the subsurface through the open well during periods of low barometric pressure. Field and modeling studies have been completed to evaluate enhancements for a passive vapor extraction system at a site contaminated with carbon tetrachloride on the Hanford nuclear reservation near Richland, Washington. During a 38-hour period of low barometric pressure, approximately 500 m{sup 3} of air were vented from the subsurface. Approximately 27 grams of carbon tetrachloride were removed from the subsurface during this same outflow event. On an annual basis, more than 15 kilograms of carbon tetrachloride have been removed from each of several passive extraction wells. Computer simulations based on the field data indicate that surface covers smaller than 30 m radius will result in relatively small enhancements of flow. However, with larger surface seals (i.e., up to 90 m radius), volumetric flow rates more than doubled. Simulations showed that check valves might increase the rate at which subsurface gases are extracted by a factor of nearly three. These estimates are sensitive to dispersion coefficients. If not properly designed, filters used to treat effluent gases from passive extraction systems can significantly reduce the effectiveness of these systems.

  8. Polyurethane foam (PUF) passive samplers for monitoring phenanthrene in stormwater.

    PubMed

    Dou, Yueqin; Zhang, Tian C; Zeng, Jing; Stansbury, John; Moussavi, Massoum; Richter-Egger, Dana L; Klein, Mitchell R

    2016-04-01

    Pollution from highway stormwater runoff has been an increasing area of concern. Many structural Best Management Practices (BMPs) have been implemented for stormwater treatment and management. One challenge for these BMPs is to sample stormwater and monitor BMP performance. The main objective of this study was to evaluate the feasibility of using polyurethane foam (PUF) passive samplers (PSs) for sampling phenanthrene (PHE) in highway stormwater runoff and BMPs. Tests were conducted using batch reactors, glass-tube columns, and laboratory-scale BMPs (bioretention cells). Results indicate that sorption for PHE by PUF is mainly linearly relative to time, and the high sorption capacity allows the PUF passive sampler to monitor stormwater events for months or years. The PUF passive samplers could be embedded in BMPs for monitoring influent and effluent PHE concentrations. Models developed to link the results of batch and column tests proved to be useful for determining removal or sorption parameters and performance of the PUF-PSs. The predicted removal efficiencies of BMPs were close to the real values obtained from the control columns with errors ranging between -8.46 and 1.52%. This research showed that it is possible to use PUF passive samplers for sampling stormwater and monitoring the performance of stormwater BMPs, which warrants the field-scale feasibility studies in the future.

  9. Method of making thermally removable polymeric encapsulants

    DOEpatents

    Small, James H.; Loy, Douglas A.; Wheeler, David R.; McElhanon, James R.; Saunders, Randall S.

    2001-01-01

    A method of making a thermally-removable encapsulant by heating a mixture of at least one bis(maleimide) compound and at least one monomeric tris(furan) or tetrakis(furan) compound at temperatures from above room temperature to less than approximately 90.degree. C. to form a gel and cooling the gel to form the thermally-removable encapsulant. The encapsulant can be easily removed within approximately an hour by heating to temperatures greater than approximately 90.degree. C., preferably in a polar solvent. The encapsulant can be used in protecting electronic components that may require subsequent removal of the encapsulant for component repair, modification or quality control.

  10. Investigations in gallium removal

    SciTech Connect

    Philip, C.V.; Pitt, W.W.; Beard, C.A.

    1997-11-01

    Gallium present in weapons plutonium must be removed before it can be used for the production of mixed-oxide (MOX) nuclear reactor fuel. The main goal of the preliminary studies conducted at Texas A and M University was to assist in the development of a thermal process to remove gallium from a gallium oxide/plutonium oxide matrix. This effort is being conducted in close consultation with the Los Alamos National Laboratory (LANL) personnel involved in the development of this process for the US Department of Energy (DOE). Simple experiments were performed on gallium oxide, and cerium-oxide/gallium-oxide mixtures, heated to temperatures ranging from 700--900 C in a reducing environment, and a method for collecting the gallium vapors under these conditions was demonstrated.

  11. Orion Passive Thermal: Control Overview

    NASA Technical Reports Server (NTRS)

    Alvarez-Hermandez, Angel; Miller, Stephen W.

    2009-01-01

    A general overview of the NASA Orion Passive Thermal Control System (PTCS) is presented. The topics include: 1) Orion in CxP Hierarchy; 2) General Orion Description/Orientation; and 3) Orion PTCS Overview.

  12. [Passive smoking. Effects on health].

    PubMed

    Trédaniel, J; Zalcman, G; Boffetta, P; Hirsch, A

    1993-05-15

    Passive smoking--also called involuntary or environmental smoking--is the exposure of non-smokers to the tobacco smoke released by smokers. The physico-chemical composition of tobacco smoke, and notably its contents in toxic and carcinogenic substances, is the same in the secondary stream between puffs as in the primary stream released by the smoker. The pathogenic effects of passive smoking are increasingly well known and accepted. A high incidence of respiratory tract infections and of chronic respiratory and asthmatic symptoms is observed in children. In adults, passive smoking seems to be one of the main risk factors for cardiovascular diseases. Its repercussions on the respiratory tracts is difficult to evaluate, but there are marked by an increase of respiratory symptoms and perhaps of chronic obstructive lung diseases. Finally, it is now recognized that passive smoking is a major risk factor for primary lung cancer in non-smokers exposed to tobacco smoke. PMID:8235360

  13. Passivating metals on cracking catalysts

    SciTech Connect

    Mckay, D.L.

    1980-01-15

    Metals such as nickel, vanadium and iron contaminating a cracking catalyst are passivated by contacting the cracking catalyst under elevated temperature conditions with antimony selenide, antimony sulfide, antimony sulfate, bismuth selenide, bismuth sulfide, or bismuth phosphate.

  14. Zinc recovery and waste sludge minimization from chromium passivation baths.

    PubMed

    Diban, Nazely; Mediavilla, Rosa; Urtiaga, Ane; Ortiz, Inmaculada

    2011-08-30

    This work reports the feasibility of applying emulsion pertraction technology (EPT) aiming at zinc recovery and waste minimization in the zinc electroplating processes that include Cr (III) passivation. The assessment consists of firstly the lifetime extension of the passivation baths by selective removal of the tramp ions zinc and iron, and secondly, the recovery of zinc for further reuse. Spent passivation baths from a local industry were tested, being the major metallic content: Cr(3+) 9000mg L(-1), Zn(2+) 12,000mg L(-1), Fe(3+) 100mg L(-1). Working in a Liqui-Cel hollow fiber membrane contactor and using the extractant bis(2,4,4-trimethylpentyl) phosphinic acid, reduction of zinc and iron concentrations below 60mg L(-1) and 2mg L(-1), respectively were obtained, while trivalent chromium, the active metal that generates the passivation layer, was retained in the baths. Zinc was selectively transferred to an acidic stripping phase that in the experimental time reached a concentration of 157,000mg L(-1). Zinc recovery by electrowinning from the acidic stripping phase without any pretreatment of the electrolyte solution provided a purity of 98.5%, matching the lower commercial zinc grade. As a result of the extension of the life time of the passivation bath, significant environmental advantages are derived such as minimization of the volume of hazardous wastes and savings in the consumption of raw materials. PMID:21704452

  15. Condensate-removal device for heat exchangers

    NASA Technical Reports Server (NTRS)

    Trusch, R. B.; Oconnor, E. W.

    1973-01-01

    Device comprises array of perforated tubes manifolded together and connected to a vacuum suction device. Vacuum applied to these tubes pulls mixture of condensate and effluent gas through perforations and along length of tubes to discharge device. Discharge device may be a separator which separates water vapor from effluent air and allows recirculation of both of them.

  16. An Improved Design for Air Removal from Aerospace Fluid Loop Coolant Systems

    NASA Technical Reports Server (NTRS)

    Ritchie, Stephen M. C.; Holladay, Jon B.; Holt, J. Mike; Clark, Dallas W.

    2003-01-01

    Aerospace applications with requirements for large capacity heat removal (launch vehicles, platforms, payloads, etc.) typically utilize a liquid coolant fluid as a transport media to increase efficiency and flexibility in the vehicle design. An issue with these systems however, is susceptibility to the presence of noncondensable gas (NCG) or air. The presence of air in a coolant loop can have numerous negative consequences, including loss of centrifugal pump prime, interference with sensor readings, inhibition of heat transfer, and coolant blockage to remote systems. Hardware ground processing to remove this air is also cumbersome and time consuming which continuously drives recurring costs. Current systems for maintaining the system free of air are tailored and have demonstrated only moderate success. An obvious solution to these problems is the development and advancement of a passive gas removal device, or gas trap, that would be installed in the flight cooling system simplifying the initial coolant fill procedure and also maintaining the system during operations. The proposed device would utilize commercially available membranes thus increasing reliability and reducing cost while also addressing both current and anticipated applications. In addition, it maintains current pressure drop, water loss, and size restrictions while increasing tolerance for pressure increases due to gas build-up in the trap.

  17. Hot Oil Removes Wax

    NASA Technical Reports Server (NTRS)

    Herzstock, James J.

    1991-01-01

    Mineral oil heated to temperature of 250 degrees F (121 degrees C) found effective in removing wax from workpieces after fabrication. Depending upon size and shape of part to be cleaned of wax, part immersed in tank of hot oil, and/or interior of part flushed with hot oil. Pump, fittings, and ancillary tooling built easily for this purpose. After cleaning, innocuous oil residue washed off part by alkaline aqueous degreasing process. Serves as relatively safe alternative to carcinogenic and environmentally hazardous solvent perchloroethylene.

  18. The design, effectiveness and construction of passive-thermal-control roofing shingles

    NASA Astrophysics Data System (ADS)

    Wolf, L., Jr.

    1982-09-01

    The concept of a passive thermal control roofing shingle, which is a shingle that reflects the summer sun and absorbs the winter sun, is discussed. It is indicated that it is possible to design shingles for particular latitudes and styles of roof which absorb nearly all of the winter solar energy and reflect nearly all of the summer solar energy. Calculations of the energy savings and cost effectiveness of the passive thermal control roofing shingle indicate that it is most cost effective on all south facing pitched roofs regardless of heating fuel type, and on flat or east or west facing roofs that are heated with costly fuels such as electricity or heating oil. The shingle is most effective on poorly insulated structures. The feasibility of using the passive thermal control roofing shingle in conjunction with a heat pump to pump heat absorbed by the shingle into a well insulated structure is demonstrated. Construction of a variety of models of the passive thermal control roofing shingle illustrate numerous alternate methods of manufacture. A profile extruded, plastic, glazed shingle appears to be the most promising approach. Use of a glazed shingle can increase the effectiveness of the passive thermal control roofing shingle by reducing convective heat losses.

  19. The side-passivation research on LWIR HgCdTe detector

    NASA Astrophysics Data System (ADS)

    Xu, Qinfei; Tang, Hengjing; Gong, Haimei

    2008-03-01

    In order to prevent Hg running over from the exposing side of HgCdTe LWIR detector with little photosensitive region, side-passivation detectors are fabricated. Then several experiments are done to characterize the side-passivation effect. Firstly, a SEM micrograph is shown, and it makes clear that wet etching and side-passivation can remove part of defect induced by IBE. Secondly, the performance measurement indicates that the performance of side-passivation detector is superior to the general one, especially for detectors with little photosensitive region. Thirdly, hot dipping is done to say that the thermal stability of side-passivation detectors is superior to general ones. And with the exception of this, the less the photosensitive region width is, the stronger the ability of protection is. Last but not the least, the detectivity of not only general detectors but also side-passivation ones increases obviously. As a whole, the performance of side-passivation detectors increases more largely than general ones. Above all, side-wall passivating film can passivate the sensitivity of detector's surface and block Hg out of the surface effectively. The results can provide experimental reference for IR semiconductor detector.

  20. CMR Shuffler System: Passive Mode Calibration and Certification Report

    SciTech Connect

    Frame, Katherine C.; Gomez, Cipriano D.; Salazar, William R.; Mayo, Douglas R.; Vigil, Georgiana M.; Crooks, William J.; Stange, Sy

    2012-07-20

    Los Alamos National Laboratory has a number of spherical confinement vessels (CVs) remaining from tests involving nuclear materials. These vessels have an inner diameter of 6 feet with 1 to 2 inch thick steel walls. The goal of the Confinement Vessel Disposition (CVD) project is to remove debris and reduce contamination inside the vessels. As debris is removed from the vessels, material will be placed in waste drums. Far-field gamma ray assay will be used to determine when a drum is nearing a {sup 239}Pu equivalent mass of less than 200 g. The drum will then be assayed using a waste drum shuffler operated in passive mode using a neutron coincidence counting method for accountability. This report focuses on the testing and calibration of the CMR waste drum shuffler in passive mode operation. Initial testing was performed to confirm previously accepted measurement parameters. The system was then calibrated using a set of weapons grade Pu (WGPu, {sup 239}Pu > 93%) oxide standards placed inside a 55 gallon drum. The calibration data ranges from Pu mass of 0.5 g to 188.9 g. The CMR waste drum shuffler has been tested and calibrated in passive mode in preparation for safeguards accountability measurements of waste drums containing material removed from CVs for the CVD project.

  1. Removing Solids From Supercritical Water

    NASA Technical Reports Server (NTRS)

    Hong, Glenn T.

    1992-01-01

    Apparatus removes precipitated inorganic salts and other solids in water-recycling process. Designed for use with oxidation in supercritical water which treats wastes and yields nearly pure water. Heating coils and insulation around vessel keep it hot. Locking bracket seals vessel but allows it to be easily opened for replacement of filled canisters.

  2. Passive test cell data for the solar laboratory winter, 1980-81

    NASA Astrophysics Data System (ADS)

    McFarland, R. D.

    1982-05-01

    Testing was done primarily to determine the relative efficiency of various passive solar heating concepts and to obtain data that could be used to validate computer simulation programs. The passive solar systems tested were Trombe wall with and without selective absorber, water wall, phase change wall, direct gain, a heat pipe collector, and two sunspace geometries. The heating load coefficient of these cells was roughly 26 Btu/h deg F and the collector area was 23.4 sq ft, giving a load collector ratio of approximately 27 Btu/deg F day sq ft. The test cell configurations and instrumentation are detailed, and the resulting data and cell efficiencies are discussed.

  3. Use of heat pipes in electronic hardware

    NASA Technical Reports Server (NTRS)

    Graves, J. R.

    1977-01-01

    A modular, multiple output power converter was developed in order to reduce costs of space hardware in future missions. The converter is of reduced size and weight, and utilizes advanced heat removal techniques, in the form of heat pipes which remove internally generated heat more effectively than conventional methods.

  4. Heat pipe array heat exchanger

    DOEpatents

    Reimann, Robert C.

    1987-08-25

    A heat pipe arrangement for exchanging heat between two different temperature fluids. The heat pipe arrangement is in a ounterflow relationship to increase the efficiency of the coupling of the heat from a heat source to a heat sink.

  5. Active heat exchange system development for latent heat thermal energy storage

    NASA Astrophysics Data System (ADS)

    Alario, J.; Haslett, R.

    1980-03-01

    Various active heat exchange concepts were identified from among three generic categories: scrapers, agitators/vibrators and slurries. The more practical ones were given a more detailed technical evaluation and an economic comparison with a passive tube-shell design for a reference application. Two concepts selected for hardware development are a direct contact heat exchanger in which molten salt droplets are injected into a cooler counterflowing stream of liquid metal carrier fluid, and a rotating drum scraper in which molten salt is sprayed onto the circumference of a rotating drum, which contains the fluid heat sink in an internal annulus near the surface. A fixed scraper blade removes the solidified salt from the surface which has been nickel plated to decrease adhesion forces. Suitable phase change material (PCM) storage media with melting points in the temperature range of interest (250 C to 400 C) were investigated. The specific salt recommended for laboratory tests was a chloride eutectic (20.5KCl-24/5 NaCl-55.0MgCl 2% by wt.), with a nominal melting point of 385 C.

  6. Active heat exchange system development for latent heat thermal energy storage

    NASA Technical Reports Server (NTRS)

    Alario, J.; Haslett, R.

    1980-01-01

    Various active heat exchange concepts were identified from among three generic categories: scrapers, agitators/vibrators and slurries. The more practical ones were given a more detailed technical evaluation and an economic comparison with a passive tube-shell design for a reference application. Two concepts selected for hardware development are a direct contact heat exchanger in which molten salt droplets are injected into a cooler counterflowing stream of liquid metal carrier fluid, and a rotating drum scraper in which molten salt is sprayed onto the circumference of a rotating drum, which contains the fluid heat sink in an internal annulus near the surface. A fixed scraper blade removes the solidified salt from the surface which has been nickel plated to decrease adhesion forces. Suitable phase change material (PCM) storage media with melting points in the temperature range of interest (250 C to 400 C) were investigated. The specific salt recommended for laboratory tests was a chloride eutectic (20.5KCl-24/5 NaCl-55.0MgCl 2% by wt.), with a nominal melting point of 385 C.

  7. Combating Frosting with Joule-Heated Liquid-Infused Superhydrophobic Coatings.

    PubMed

    Elsharkawy, Mohamed; Tortorella, Domenico; Kapatral, Shreyas; Megaridis, Constantine M

    2016-05-01

    Frost formation is omnipresent when suitable environmental conditions are met. A good portion of research on combating frost formation has revolved around the passive properties of superhydrophobic (SHPO) and slippery lubricant-impregnated porous (SLIP) surfaces. Despite much progress, the need for surfaces that can effectively combat frost formation over prolonged periods still remains. In this work, we report, for the first time, the use of electrically conductive SHPO/SLIP surfaces for active mitigation of frost formation. First, we demonstrate the failure of these surfaces to passively avert prolonged (several hours) frosting. Next, we make use of their electroconductive property for active Joule heating, which results in the removal of any formed frost. We study the role of the impregnating lubricant in the heat transfer across the interface, the surface, and the ambient. We show that, even though the thermal properties of the impregnating lubricant may vary drastically, the lubricant type does not noticeably affect the defrosting behavior of the surface. We attribute this outcome to the dominant thermal resistance of the thick frost layer formed on the cooled surface. We support this claim by drawing parallels between the present system and heat transfer through a one-dimensional (1D) composite medium, and solving the appropriate transient transport equations. Lastly, we propose periodic thermal defrosting for averting frost formation altogether. This methodology utilizes the coating's passive repellent capabilities, while eliminating the dominant effect of thick deposited frost layers. The periodic heating approach takes advantage of lubricants with higher thermal conductivities, which effectively enhance heat transfer through the porous multiphase surface that forms the first line of defense against frosting. PMID:27021948

  8. Passive Wake Vortex Control

    SciTech Connect

    Ortega, J M

    2001-10-18

    works by placing shape memory alloy (SMA) control surfaces on the submarine's diving planes and periodically oscillating them. The modulated control vortices generated by these surfaces interact with the tip vortices on the diving planes, causing an instability to rapidly occur. Though several numerical simulations have been presented, experimental verification does not appear to be available in the open literature. The authors address this problem through a concept called passive wake vortex control (PWVC), which has been demonstrated to rapidly break apart a trailing vortex wake and render it incoherent. PWVC functions by introducing unequal strength, counter-rotating control vortices next to the tip vortices. The presence of these control vortices destabilizes the vortex wake and produces a rapidly growing wake instability.

  9. Passive solar energy information user study

    SciTech Connect

    Belew, W.W.; Wood, B.L.; Marle, T.L.; Reinhardt, C.L.

    1980-11-01

    The results of a series of telephone interviews with groups of users of information on passive solar heating and cooling are described. These results, part of a larger study on many different solar technologies, identify types of information each group needed and the best ways to get information to each group. The overall study provides baseline data about information needs in the solar community. An earlier study identified the information user groups in the solar community and the priority (to accelerate solar energy commercialization) of getting information to each group. In the current study only high-priority groups were examined. Results from seven passive groups respondents are analyzed in this report: Federally Funded Researchers, Manufacturer Representatives, Architects, Builders, Educators, Cooperative Extension Service County Agents, and Homeowners. The data will be used as input to the determination of information products and services the Solar Energy Research Institute, the Solar Energy Information Data Bank Network, and the entire information outreach community should be preparing and disseminating.

  10. Method to Increase Performance of Foil Bearings Through Passive Thermal Management

    NASA Technical Reports Server (NTRS)

    Bruckner, Robert

    2013-01-01

    This invention is a new approach to designing foil bearings to increase their load capacity and improve their reliability through passive thermal management. In the present case, the bearing is designed in such a way as to prevent the carryover of lubricant from the exit of one sector to the inlet of the ensuing sector of the foil bearing. When such passive thermal management techniques are used, bearing load capacity is improved by multiples, and reliability is enhanced when compared to current foil bearings. This concept has recently been tested and validated, and shows that load capacity performance of foil bearings can be improved by a factor of two at relatively low speeds with potentially greater relative improvements at higher speeds. Such improvements in performance with respect to speed are typical of foil bearings. Additionally, operation of these newly conceived bearings shows much more reliability and repeatable performance. This trait can be exploited in machine design to enhance safety, reliability, and overall performance. Finally, lower frictional torque has been demonstrated when operating at lower (non-load capacity) loads, thus providing another improvement above the current state of the art. The objective of the invention is to incorporate features into a foil bearing that both enhance passive thermal management and temperature control, while at the same time improve the hydrodynamic (load capacity) performance of the foil bearing. Foil bearings are unique antifriction devices that can utilize the working fluid of a machine as a lubricant (typically air for turbines and motors, liquids for pumps), and as a coolant to remove excess energy due to frictional heating. The current state of the art of foil bearings utilizes forced cooling of the bearing and shaft, which represents poor efficiency and poor reliability. This invention embodies features that utilize the bearing geometry in such a manner as to both support load and provide an inherent and

  11. Passive solar renovation of an existing commercial greenhouse

    SciTech Connect

    McGinnis, J.W.; Whitehead, N.

    1980-01-01

    The renovation of an existing 1800 square foot commercial greenhouse to incorporate passive solar reliant and energy conserving features is detailed. The Aquatic-Agriculture Institute for Research, a non-profit group, sponsored the project to develop efficient production methods to raise vegetables and fish at the community level. The performance of the remodeled greenhouse will be compared to the performance of the same greenhouse as it was originally designed. The restored greenhouse began operation in September 1979. Accurate fuel and temperature records maintained through-out the past winter, show the cost of back-up heating under operating conditions to be approximately $150.00. Old fuel receipts dating back into the 1940's show an average use of 2000 gallons of heating fuel each winter prior to remodeling. This would indicate a yearly fuel savings of better than 90% through the use of passive solar techniques.

  12. A Wireless and Passive Low-Pressure Sensor

    PubMed Central

    Nicolay, Pascal; Lenzhofer, Martin

    2014-01-01

    This paper will discuss the results obtained with a first prototype of a completely passive and wireless low pressure sensor. The device is a heat conductivity gauge, based on a wireless and passive SAW temperature sensor. The required heating energy is applied to the sensor using inductive coupling. The prototype was successfully tested in a vacuum chamber. Its equilibrium temperature changed drastically and in a reproducible way when pressure steps were applied. However, the response time was very long. A model is provided to account for the sensor's behavior. It is then used to show that the response time could be strongly improved using basic design improvements. Further possible improvements are discussed. PMID:24549249

  13. Removable preheater elements improve oxide induction furnace

    NASA Technical Reports Server (NTRS)

    Leipold, M. H.

    1964-01-01

    Heat and corrosion resistant preheater elements are used in oxide induction furnaces to raise the temperature to the level for conducting electricity. These preheater elements are then removed and the induction coil energized.

  14. Heat distribution by natural convection

    SciTech Connect

    Balcomb, J.D.

    1985-01-01

    Natural convection can provide adequate heat distribution in many situtations that arise in buildings. This is appropriate, for example, in passive solar buildings where some rooms tend to be more strongly solar heated than others or to reduce the number of heating units required in a building. Natural airflow and heat transport through doorways and other internal building apertures is predictable and can be accounted for in the design. The nature of natural convection is described, and a design chart is presented appropriate to a simple, single-doorway situation. Natural convective loops that can occur in buildings are described and a few design guidelines are presented.

  15. Vacuum powered heat exchanger

    SciTech Connect

    Ruffolo, R.F.

    1986-06-24

    In an internal combustion engine including an oil lubrication system, a liquid cooling system, and an improved air intake system is described. The improved air intake system comprises: a housing including a first opening in one end, which opening is open to the atmosphere and a second opening comprising an air outlet opening in the other end open to the air intake manifold of the engine, a heat exchanger positioned in the first opening. The heat exchanger consists of a series of coils positioned in the flow path of the atmospheric air as it enters the housing, the heat exchanger being fluidly connected to either the engine lubrication system or the cooling system to provide a warm heat source for the incoming air to the housing, acceleration means positioned in the housing downstream of the heat exchanger, the acceleration means comprising a honeycomb structure positioned across the air intake flow path. The honey-comb structure includes a multitude of honey combed mini-venturi cells through which the heated air flows in an accelerated mode, a removable air filter positioned between the heat exchanger and the acceleration means and a single opening provided in the housing through which the air filter can be passed and removed, and additional openings in the housing positioned downstream of the heat exchanger and upstream of the air filter, the additional openings including removable flaps for opening and closing the openings to control the temperature of the air flowing through the housing.

  16. Passive solar hen house--Second year

    SciTech Connect

    MacDougall, E.A.

    1980-12-01

    This paper describes the second year's study of a passive solar hen house. The first year's study demonstrated that a small flock of hens living in a solar heated environment can produce more eggs at a better feed efficiency than that predicted by the U.S. Department of Agriculture (USDA) for hens housed in standard hen housing. For this second year's work a new flock of Rhode Island Reds was raised and then divided in two groups - one housed in the solar hen house; the other in a barn. The solar housed group showed slightly better feed efficiency, but the barn housed group had better egg production. Both groups produced consistently heavier eggs than comparative commercial hens. However, the commercial hens showed higher feed efficiency than either the barn housed or the solar housed group for the 15 week test.

  17. Barrier height enhancement of Ni/GaN Schottky diode using Ru based passivation scheme

    SciTech Connect

    Kumar, Ashish Kumar, Mukesh; Singh, R.; Kaur, Riajeet; Joshi, Amish G.; Vinayak, Seema

    2014-03-31

    Wet chemical passivation of n-GaN surface using Ru based solution has been reported. X-ray photoelectron spectroscopy characterization of the GaN surface revealed removal of surface oxides by the introduction of Ru complex species. Ni/n-GaN Schottky barrier diodes were fabricated on passivated GaN and a remarkable improvement in Schottky barrier height from 0.76 eV to 0.92 eV was observed.

  18. Silicon Heat Pipe Array

    NASA Technical Reports Server (NTRS)

    Yee, Karl Y.; Ganapathi, Gani B.; Sunada, Eric T.; Bae, Youngsam; Miller, Jennifer R.; Beinsford, Daniel F.

    2013-01-01

    Improved methods of heat dissipation are required for modern, high-power density electronic systems. As increased functionality is progressively compacted into decreasing volumes, this need will be exacerbated. High-performance chip power is predicted to increase monotonically and rapidly with time. Systems utilizing these chips are currently reliant upon decades of old cooling technology. Heat pipes offer a solution to this problem. Heat pipes are passive, self-contained, two-phase heat dissipation devices. Heat conducted into the device through a wick structure converts the working fluid into a vapor, which then releases the heat via condensation after being transported away from the heat source. Heat pipes have high thermal conductivities, are inexpensive, and have been utilized in previous space missions. However, the cylindrical geometry of commercial heat pipes is a poor fit to the planar geometries of microelectronic assemblies, the copper that commercial heat pipes are typically constructed of is a poor CTE (coefficient of thermal expansion) match to the semiconductor die utilized in these assemblies, and the functionality and reliability of heat pipes in general is strongly dependent on the orientation of the assembly with respect to the gravity vector. What is needed is a planar, semiconductor-based heat pipe array that can be used for cooling of generic MCM (multichip module) assemblies that can also function in all orientations. Such a structure would not only have applications in the cooling of space electronics, but would have commercial applications as well (e.g. cooling of microprocessors and high-power laser diodes). This technology is an improvement over existing heat pipe designs due to the finer porosity of the wick, which enhances capillary pumping pressure, resulting in greater effective thermal conductivity and performance in any orientation with respect to the gravity vector. In addition, it is constructed of silicon, and thus is better

  19. Method of making thermally removable epoxies

    DOEpatents

    Loy, Douglas A.; Wheeler, David R.; Russick, Edward M.; McElhanon, James R.; Saunders, Randall S.

    2002-01-01

    A method of making a thermally-removable epoxy by mixing a bis(maleimide) compound to a monomeric furan compound containing an oxirane group to form a di-epoxy mixture and then adding a curing agent at temperatures from approximately room temperature to less than approximately 90.degree. C. to form a thermally-removable epoxy. The thermally-removable epoxy can be easily removed within approximately an hour by heating to temperatures greater than approximately 90.degree. C. in a polar solvent. The epoxy material can be used in protecting electronic components that may require subsequent removal of the solid material for component repair, modification or quality control.

  20. The REPAS Study: Reliability Evaluation of Passive Safety Systems

    SciTech Connect

    Ricotti, M.E.; Bianchi, F.; Burgazzi, L.; D'Auria, F.; Galassi, G.

    2002-07-01

    The strategy of approach to the problem moves from the consideration that a passive system should be theoretically more reliable than an active one. In fact it does not need any external input or energy to operate and it relies only upon natural physical laws (e.g. gravity, natural circulation, internally stored energy, etc.) and/or 'intelligent' use of the energy inherently available in the system (e.g. chemical reaction, decay heat, etc.). Nevertheless the passive system may fail its mission not only as a consequence of classical mechanical failure of components, but also for deviation from the expected behaviour, due to physical phenomena mainly related to thermal-hydraulics or due to different boundary and initial conditions. The main sources of physical failure are identified and a probability of occurrence is assigned. The reliability analysis is performed on a passive system which operates in two-phase, natural circulation. The selected system is a loop including a heat source and a heat sink where the condensation occurs. The system behavior under different configurations has been simulated via best-estimate code (Relap5 mod3.2). The results are shown and can be treated in such a way to give qualitative and quantitative information on the system reliability. Main routes of development of the methodology are also depicted. (authors)

  1. Steam-oxygen and steam-water-oxygen methods for cleaning, passivation, and conservation of power engineering equipment

    NASA Astrophysics Data System (ADS)

    Man'kina, N. N.; Gol'Din, A. A.; Stolyarov, A. A.

    2008-07-01

    This publication presents results of efficient use of a developed technology for cleaning, passivating, and conservation of the heat-exchange equipment of industrial boilers and steam turbines of thermal power stations.

  2. Extraction of small boat harmonic signatures from passive sonar.

    PubMed

    Ogden, George L; Zurk, Lisa M; Jones, Mark E; Peterson, Mary E

    2011-06-01

    This paper investigates the extraction of acoustic signatures from small boats using a passive sonar system. Noise radiated from a small boats consists of broadband noise and harmonically related tones that correspond to engine and propeller specifications. A signal processing method to automatically extract the harmonic structure of noise radiated from small boats is developed. The Harmonic Extraction and Analysis Tool (HEAT) estimates the instantaneous fundamental frequency of the harmonic tones, refines the fundamental frequency estimate using a Kalman filter, and automatically extracts the amplitudes of the harmonic tonals to generate a harmonic signature for the boat. Results are presented that show the HEAT algorithms ability to extract these signatures.

  3. Performance analysis of 11 Denver Metro passive homes

    NASA Astrophysics Data System (ADS)

    Claridge, D. E.

    1981-07-01

    The auxiliary heating requirements for 11 passive solar homes were calculated using SLR or SUNCAT-2.4 with a standard set of basic assumptions. It is shown that: seven of the homes should use less than half as much heating fuel as typical houses, two should use about half, and two should use about two-thirds or more. These results are compared with performance estimates and show large discrepancies. Differences are attributed largely to specific differences in assumptions in every case but one.

  4. Radionuclide removal

    SciTech Connect

    Sorg, T.J.

    1991-01-01

    The U.S. Environmental Protection Agency proposed new and revised regulations on radionuclide contaminants in drinking water in June 1991. During the 1980's, the Drinking Water Research Division, USEPA conducted a research program to evaluate various technologies to remove radium, uranium and radon from drinking water. The research consisted of laboratory and field studies conducted by USEPA, universities and consultants. The paper summarizes the results of the most significant projects completed. General information is also presented on the general chemistry of the three radionuclides. The information presented indicates that the most practical treatment methods for radium are ion exchange and lime-soda softening and reverse osmosis. The methods tested for radon are aeration and granular activated carbon and the methods for uranium are anion exchange and reverse osmosis.

  5. Heat exchange apparatus utilizing thermal siphon pipes

    SciTech Connect

    Daman, E.L.; Kunsagi, L.

    1980-10-07

    A heat exchange apparatus is descirbed in which each of a plurality of thermal siphon pipes has an upper portion extending in an upper heat exchange section and a lower portion extending in a lower heat exchange section. Each pipe is closed at its ends and contains a heat transfer fluid so that when a hot fluid is passed through the lower heat exchange section, the heat is transferred from the hot fluid to the heat exchange fluid. A cool fluid is passed through the upper heat exchange section to remove the heat from the heat exchange fluid.

  6. Removing Bonded Integrated Circuits From Boards

    NASA Technical Reports Server (NTRS)

    Rice, John T.

    1989-01-01

    Small resistance heater makes it easier, faster, and cheaper to remove integrated circuit from hybrid-circuit board, package, or other substrate for rework. Heater, located directly in polymeric bond interface or on substrate under integrated-circuit chip, energized when necessary to remove chip. Heat generated softens adhesive or solder that bonds chip to substrate. Chip then lifted easily from substrate.

  7. Thermal removal of asbestos pipeline coating

    SciTech Connect

    Stevens, W.H.

    1997-03-01

    A heat (thermal) technique, not previously used in the US for removing external pipe coating was used to remove asbestos-wrapped coating from 17 miles of 24-inch-diameter pipe. The process was conducted in compliance with all asbestos and air quality regulations, and produced asbestos-free pipe at timely and cost-effective rates.

  8. Passivated ambipolar black phosphorus transistors.

    PubMed

    Yue, Dewu; Lee, Daeyeong; Jang, Young Dae; Choi, Min Sup; Nam, Hye Jin; Jung, Duk-Young; Yoo, Won Jong

    2016-07-01

    We report the first air-passivated ambipolar BP transistor formed by applying benzyl viologen, which serves as a surface charge transfer donor for BP flakes. The passivated BP devices exhibit excellent stability under both an ambient atmosphere and vacuum; their transistor performance is maintained semi-permanently. Unlike their intrinsic p-type properties, passivated BP devices present advantageous ambipolar properties with much higher electron mobility up to ∼83 cm(2) V(-1) s(-1) from 2-terminal measurement at 300 K, compared to other reported studies on n-type BP transistors. On the basis of the n-type doping effect that originated from benzyl viologen, we also systematically investigated the BP thickness dependence of our devices on electrical properties, in which we found the best electron transport performance to be attained when an ∼10 nm thick BP flake was used. PMID:27283027

  9. Passivation of high temperature superconductors

    NASA Technical Reports Server (NTRS)

    Vasquez, Richard P. (Inventor)

    1991-01-01

    The surface of high temperature superconductors such as YBa2Cu3O(7-x) are passivated by reacting the native Y, Ba and Cu metal ions with an anion such as sulfate or oxalate to form a surface film that is impervious to water and has a solubility in water of no more than 10(exp -3) M. The passivating treatment is preferably conducted by immersing the surface in dilute aqueous acid solution since more soluble species dissolve into the solution. The treatment does not degrade the superconducting properties of the bulk material.

  10. The anodic passivation of lithium

    SciTech Connect

    James, S.D.

    1983-10-01

    The anodic passivation of Li has been characterized at room temperature in a variety of electrolytes (propylene carbonate, thionyl chloride, sulfur dioxide), as a function of convection and current density and in the presence of water and other impurities. In thionyl chloride the effect of salt concentration (0.5-4.5M, LiA1C1/sub 4/) and acidity (0.5-3M, A1C1/sub 3/) has been studied. The evidence accumulated suggests that anodic passivation is caused by anodic enrichment and eventual precipitation of electrolyte salt in superficial anolyte.

  11. Passive solar renovations to the Common Ground Community Restaurant. Final report

    SciTech Connect

    Not Available

    1985-01-01

    The passive solar and energy conserving renovations to the Common Ground Community Restaurant were funded primarily as a demonstration project under this program. The majority of work accomplished was (1) design and construction of a passive solar greenhouse on the existing second floor porch of the restaurant, and (2) the design and construction of energy conserving improvements to the interior of the building, consisting largely of renovating the walls and ceiling to provide an insulated space with a substantially reduced heat load.

  12. Simulation of the passive condensation cooling tank of the PASCAL test facility using the component thermal-hydraulic analysis code CUPID

    SciTech Connect

    Cho, H. K.; Lee, S. J.; Kang, K. H.; Yoon, H. Y.

    2012-07-01

    For the analysis of transient two-phase flows in nuclear reactor components, a three-dimensional thermal hydraulics code, named CUPID, has been being developed. In the present study, the CUPID code was applied for the simulation of the PASCAL (PAFS Condensing Heat Removal Assessment Loop) test facility constructed with an aim of validating the cooling and operational performance of the PAFS (Passive Auxiliary Feedwater System). The PAFS is one of the advanced safety features adopted in the APR+ (Advanced Power Reactor +), which is intended to completely replace the conventional active auxiliary feedwater system. This paper presents the preliminary simulation results of the PASCAL facility performed with the CUPID code in order to verify its applicability to the thermal-hydraulic phenomena inside the system. A standalone calculation for the passive condensation cooling tank was performed by imposing a heat source boundary condition and the transient thermal-hydraulic behaviors inside the system, such as the water level, temperature and velocity, were qualitatively investigated. The simulation results verified that the natural circulation and boiling phenomena in the water pool can be well reproduced by the CUPID code. (authors)

  13. Heat management in aluminum/air batteries: Sources of heat

    NASA Astrophysics Data System (ADS)

    Patnaik, R. S. M.; Ganesh, S.; Ashok, G.; Ganesan, M.; Kapali, V.

    1994-07-01

    One of the problems with the aluminum/air battery is the generation of heat, during both idle and discharge periods. The main sources of heat are: (1) corrosion of the aluminum anode during the idle period; (2) inefficient, or less efficient, dissolution of anode during discharge; (3) Joule heat during discharge, and (4) non-uniform mass transfer during both discharge and idle periods. These components of heat act in a cumulative way because they are all interconnected. This paper addresses the basic reasons for the origin of these sources of heat. Suitable and practical remedial measures for the effective removal of such heat in the aluminum/air battery are suggested.

  14. Starch removal from potato tuber sections.

    PubMed

    Fronda, A; Jona, R

    1991-01-01

    Heating plant sections at 90 C with 0.5% aqueous ammonium oxalate is required to remove pectins. When applied to tissues rich in starch such as potato, this step produces heavy dextrinization of the starch which hinders subsequent evaluation of the extinction values of the cell walls. To overcome this a method has been devised to brush away the starch granules from the sections with a thin paint brush, just after paraffin removal by xylene. The slide is then processed as usual: pectins are removed by heat treatment, cell walls are stained with PAS and the stain intensity can be evaluated by photometry. PMID:1790235

  15. Passive Reactor Cooling Using Capillary Porous Wick

    SciTech Connect

    Miller, Christopher G.; Lin, Thomas F.

    2006-07-01

    Long-term reliability of actively pumped cooling systems is a concern in space-based nuclear reactors. Capillary-driven passive cooling systems are being considered as an alternative to gravity-driven systems. The high surface tension of liquid lithium makes it attractive as the coolant in a capillary-driven cooling system. A system has been conceived in which the fuel rod of a reactor is surrounded by a concentric wick through which liquid lithium flows to provide cooling under normal and emergency operating conditions. Unheated wicking experiments at three pressures using four layered screen mesh wicks of different porosities and three relatively high surface tension fluids have been conducted to gain insight into capillary phenomena for such a capillary cooling system. All fluids tested demonstrated wicking ability in each of the wick structures for all pressures, and wicking ability for each fluid increased with decreasing wick pore size. An externally heated wicking experiment with liquid lithium as the wicking fluid was also conducted. In addition to wicking experiments, a heater rod is under development to simulate the fuel rod of a space based nuclear reactor by providing a heat flux of up to 110 kW/m{sup 2}. Testing of this heater rod has shown its ability to undergo repeated cycling from below 533 K to over 1255 K without failure. This heater rod will be integrated into lithium wicking experiments to provide more realistic simulation of the proposed capillary-driven space nuclear reactor cooling system. (authors)

  16. The Passive Aggressive Conflict Cycle

    ERIC Educational Resources Information Center

    Whitson, Signe

    2013-01-01

    Understanding the Passive Aggressive Conflict Cycle (PACC) helps observers to be able to look beyond behavior and better understand what is occurring beneath the surface. This article presents a real-life example of a seemingly minor conflict between a teacher and child that elicited an apparent major overreaction by the adult. Also provided is a…

  17. Orion Passive Thermal Control Overview

    NASA Technical Reports Server (NTRS)

    Miller, Stephen W.

    2007-01-01

    An viewgraph presentation of Orion's passive thermal control system is shown. The topics include: 1) Orion in CxP Hierarchy; 2) General Orion Description/Orientation; 3) Module Descriptions and Images; 4) Orion PTCS Overview; 5) Requirements/Interfaces; 6) Design Reference Missions; 7) Natural Environments; 8) Thermal Models; 9) Challenges/Issues; and 10) Testing

  18. [Passive smoking--active killer].

    PubMed

    Palavra, Irena Rojnić; Franelić, Iva Pejnović; Milanović, Sanja Musić; Puljić, Kresimir

    2013-01-01

    Although still not perceived in this way, passive smoking is a public health issue of great importance. World Health Organization estimates that as a result of passive exposure to tobacco smoke each year 600,000 people die, of which 165,000 children. There are 33% of men, 35% of women and 40% of children who do not smoke, but are exposed to second hand smoke, and still only 11% of the world population is protected by adequate smoke-free legislation. Scientific literature provides evidence that passive exposure to tobacco smoke can result in numerous adverse health effects: asthma and allergies, respiratory infections and (middle) ear infections, cancers of various localization, accelerated atherosclerosis and cardiovascular diseases, retardation of growth and development in children, and in pregnancy it can lead to congenital anomalies and premature birth as well as lower body weight and length of the child. Certainly, the scariest consequence of all is sudden infant death syndrome, also called "death in the crib". Smoke-free policies have proven their effectiveness, but while implementing the laws, it is necessary to raise public awareness of the hazards of, both active and passive, exposure to tobacco smoke. PMID:24490334

  19. Passivated ambipolar black phosphorus transistors

    NASA Astrophysics Data System (ADS)

    Yue, Dewu; Lee, Daeyeong; Jang, Young Dae; Choi, Min Sup; Nam, Hye Jin; Jung, Duk-Young; Yoo, Won Jong

    2016-06-01

    We report the first air-passivated ambipolar BP transistor formed by applying benzyl viologen, which serves as a surface charge transfer donor for BP flakes. The passivated BP devices exhibit excellent stability under both an ambient atmosphere and vacuum; their transistor performance is maintained semi-permanently. Unlike their intrinsic p-type properties, passivated BP devices present advantageous ambipolar properties with much higher electron mobility up to ~83 cm2 V-1 s-1 from 2-terminal measurement at 300 K, compared to other reported studies on n-type BP transistors. On the basis of the n-type doping effect that originated from benzyl viologen, we also systematically investigated the BP thickness dependence of our devices on electrical properties, in which we found the best electron transport performance to be attained when an ~10 nm thick BP flake was used.We report the first air-passivated ambipolar BP transistor formed by applying benzyl viologen, which serves as a surface charge transfer donor for BP flakes. The passivated BP devices exhibit excellent stability under both an ambient atmosphere and vacuum; their transistor performance is maintained semi-permanently. Unlike their intrinsic p-type properties, passivated BP devices present advantageous ambipolar properties with much higher electron mobility up to ~83 cm2 V-1 s-1 from 2-terminal measurement at 300 K, compared to other reported studies on n-type BP transistors. On the basis of the n-type doping effect that originated from benzyl viologen, we also systematically investigated the BP thickness dependence of our devices on electrical properties, in which we found the best electron transport performance to be attained when an ~10 nm thick BP flake was used. Electronic supplementary information (ESI) available: Transfer characteristics of BP field effect transistors (BV1-BV4) (Fig. S1 and S2 and Table S1); output characteristics of BP field effect transistors in different directions (Fig. S3

  20. Analysis of panthers full-scale heat transfer tests with RELAP5

    SciTech Connect

    Parlatan, Y.; Boyer, B.D.; Jo, J.; Rohatgi, S.

    1996-01-01

    The RELAP5 code is being assessed on the full-scale Passive Containment Cooling System (PCCS) in the Performance ANalysis and Testing of HEat Removal Systems (PANTHERS) facility at Societa Informazioni Termoidrauliche (SIET) in Italy. PANTHERS is a test facility with fall-size prototype beat exchangers for the PCCS in support of the General Electric`s (GE) Simplified Boiling Water Reactor (SBWR) program. PANTHERS tests with a low noncondensable gas concentration and with a high noncondensable gas concentration were analyzed with RELAP5. The results showed that beat transfer rate decreases significantly along the PCCS tubes. In the test case with a higher inlet noncondensable gas fraction, the PCCS removed 35% less heat than in the test case with the lower noncondensable gas fraction. The dominant resistance to the overall heat transfer is the condensation beat transfer resistance inside the tubes. This resistance increased by about 5-fold between the inlet and exit of the tube due to the build up of noncondensable gases along the tube. The RELAP5 calculations also predicted that 4% to 5% of the heat removed to the PCCS pool occurs in the inlet steam piping and PCCS upper and lower headers. These piping needs to be modeled for other tests systems. The full-scale PANTHERS predictions are also compared against 1/400 scale GIRAFFE tests. GIRAFFE has 33% larger heat surface area, but its efficiency is only 15% and 23% higher than PANTHERS for the two cases analyzed This was explained by the high heat transfer resistance inside the tubes near the exit.