Sample records for patch repair material

  1. Comparison of shrinkage related properties of various patch repair materials

    NASA Astrophysics Data System (ADS)

    Kristiawan, S. A.; Fitrianto, R. S.

    2017-02-01

    A patch repair material has been developed in the form of unsaturated polyester resin (UPR)-mortar. The performance and durability of this material are governed by its compatibility with the concrete being repaired. One of the compatibility issue that should be tackled is the dimensional compatibility as a result of differential shrinkage between the repair material and the concrete substrate. This research aims to evaluate such shrinkage related properties of UPR-mortar and to compare with those of other patch repair materials. The investigation includes the following aspects: free shrinkage, resistance to delamination and cracking. The results indicate that UPR-mortar poses a lower free shrinkage, lower risk of both delamination and cracking tendency in comparison to other repair materials.

  2. Aortic valve repair with autologous pericardial patch.

    PubMed

    Lausberg, Henning F; Aicher, Diana; Langer, Frank; Schäfers, Hans-Joachim

    2006-08-01

    Isolated aortic valve repair (AVR) has been gaining increasing interest in recent times. Results of isolated aortic valve repair have been reported to be variable. Various techniques have been utilized. We analyzed our experience with isolated valve repair using autologous pericardial patch plasty and compared the results to an age-matched collective with aortic valve repair without the use of additional material. Between January 1997 and June 2005, pericardial patch plasty of the aortic valve was performed in 42 patients (PATCH). During the same period, 42 patients after AVR without the use of additional material were age matched (NO-PATCH). Mean age in both groups was 52 years with a majority of male patients (PATCH ratio, 3.7:1; NO-PATCH ratio, 5:1). Valve anatomy was similar in both groups. All patients were followed by echocardiography for a cumulative follow-up of 2341 patient months (mean 28+/-23 months). No patient died in the hospital in neither group. The average systolic gradient was 5.9+/-2.2 mmHg in PATCH and 4.8+/-2.1 mmHg in NO-PATCH; p=0.17). Freedom from aortic regurgitation > or = II degrees was 87.8% in PATCH and 95.0% in NO-PATCH after 5 years (p=0.21). Freedom from reoperation was 97.6% in PATCH and 97.4% in NO-PATCH (p=0.96). Aortic regurgitation can be treated effectively by aortic valve repair using pericardial patch plasty. The functional results are satisfactory. With the application of this technique also more complex pathologies of the aortic valve can be addressed adequately thus extending the concept of valve preservation in patients with aortic regurgitation.

  3. Thermal Analysis by Numerical Methods of Debonding Effects near the Crack Tip under Composite Repairs

    NASA Astrophysics Data System (ADS)

    Tsamasphyros, G. J.; Kanderakis, G. N.; Marioli-Riga, Z. P.

    2003-05-01

    Composite patch repair of metallic structures has become a rapidly grown technology in the aerospace field due to the demand for significant increases in the useful life of both military and civilian aircraft. This has led to significant advances overall in the repair technology of cracked metallic structures. Adhesively bonded composite reinforcements offer remarkable advantages such as mechanical efficiency, repair time, cost reduction, high structural integrity, repair inspectability, damage tolerance to further causes of future strains, anticorrosion and antifretting properties. However, because of the different nature and properties of the materials that form a repair (metals, composites, adhesives), side-effects may occur: debonding due to high stress concentration in the vicinity of the crack, thermal residual stresses because of different thermal expansion coefficients of the adherents, etc. In this paper a three-dimensional finite elements analysis of the area around a patch repaired crack of a typical aircraft fuselage is performed, taking into account both the properties and the geometry of the involved materials. Examined in this case are 2024-T3 aluminum alloy as base material, FM-73 as the adhesive system and F4/5521 boron/epoxy prepreg as the patch material. Through the thickness stresses near the crack tip and along the patch edges with and without temperature effects are calculated and debonding near the crack tip is examined. Finally, the calculated results are compared with existing theories.

  4. Cementitious materials for thin patches : final report.

    DOT National Transportation Integrated Search

    2001-06-01

    Ten cementitious patching materials, which were suitable for thin, vertical repairs according to the manufacturers, were evaluated. Compatibility with cathodic protection systems was a particular concern. The materials were tested for propensity to c...

  5. Formulation and Evaluation of a Novel Adhesive Film for Use in Composite Patch Repair

    NASA Astrophysics Data System (ADS)

    Tsamasphyros, G.; Kalkanis, K.; Maroulas, P.; Anthoulis, G. I.; Grigoryeva, O.

    2008-08-01

    The current work focuses on the testing of a novel material used as an adhesive film in Composite Patch Repair (CPR). A series of Differential Scanning Calorimetry (DSC) results along with various curing cycles not only led to the optimum material composition but also demonstrated the compatibility to the composite pre-impregnated patches. This in turn was subjected to mechanical testing including shear strength measurements. The substrate was chosen to be 2017 T4 aluminium alloy which is customarily used in the aerospace industry, taking into account that CPR is a technique mainly applied in this field. The subsequent surface preparation of the specimens was investigated for the specified context resulting to the selection of the Ferric Sulphate Sulphuric acid etching process. Finally, a series of specimens representing actual skin repairs were created and subjected to cyclic loading, specifying the suitability of the novel material, compared to commercially available materials.

  6. Lightweight Material Patches Allow for Quick Repairs

    NASA Technical Reports Server (NTRS)

    2010-01-01

    Cornerstone Research Group Inc., of Dayton, Ohio, has been the recipient of 16 Small Business Innovation Research (SBIR) contracts with NASA with a variety of different focuses, including projects like creating inflatable structures for radio frequency antennas and, most recently, healable polymer matrix composites for future space vehicles. One of its earlier SBIR contracts, with Kennedy Space Center, led to the development of a new type of structural patch for a variety of consumer uses: Rubbn Repair, for automotive uses; and Rec Repair for the outdoors and adventure market. Both are flexible, heat-activated structural patches.

  7. Evaluation of concrete patching materials : final report.

    DOT National Transportation Integrated Search

    1985-01-01

    The project evaluated numerous repairs on portland cement concrete pavements and bridge decks made with a number of laboratory accepted, proprietary patching materials and portland cement concrete mixtures of different designs. It was ascertained tha...

  8. UV-cured adhesives for carbon fiber composite applications

    NASA Astrophysics Data System (ADS)

    Lu, Hsiao-Chun

    Carbon fiber composite materials are increasingly used in automobile, marine, and aerospace industries due to their unique properties, including high strength, high stiffness and low weight. However, due to their brittle characteristic, these structures are prone to physical damage, such as a bird strike or impact damage. Once the structure is damaged, it is important to have fast and reliable temporary repair until the permanent repair or replacement can take place. In this dissertation, UV-based adhesives were used to provide a bonding strength for temporary repair. Adhesively bonded patch repair is an efficient and effective method for temporary repair. In this study, precured patches (hard patches) and dry fabric patches with laminating resins (soft patches) were performed. UV-based epoxy adhesives were applied to both patch repair systems. For precured patch repair, the bonding strengths were investigated under different surface treatments for bonding area and different adhesives thicknesses. The shear stresses of different UV exposure times and curing times were tested. Besides, the large patch repair was investigated as well. For soft patch repair, the hand wet lay-up was applied due to high viscosity of UV resins. A modified single lap shear testing (ASTM D5868) was applied to determine the shear stress. The large patches used fiber glass instead of carbon fiber to prove the possibility of repair with UV epoxy resin by hand wet lay-up process. The hand lay-up procedure was applied and assisted by vacuum pressure to eliminate the air bubbles and consolidate the patches. To enhance the bonding strength and effective soft patch repair, vacuum assisted resin transferring molding (VaRTM) is the better option. However, only low viscosity resins can be operated by VaRTM. Hence, new UV-based adhesives were formulated. The new UV-based adhesives included photoinitiator (PI), epoxy and different solvents. Solvents were used to compound the photoinitiator into epoxy monomer. Acetone, tetrahydrofuran (THF) and chloroform were used as well as their anhydrous solvents. The UV exposure times and curing times of new UV-based resins were tested. FT-IR, DSC and DMA were used to investigate structure, glass transition temperatures(Tg) and properties of polymer. In summary, the UV-based adhesive was applied to adhesively bonded hard patch and soft patch repair. In addition, new UV-based resins were formulated for the VaRTM process. The in-field repair can be effective and efficient by using UV adhesives.

  9. Evaluation of cold mixes for winter pothole repair.

    DOT National Transportation Integrated Search

    1995-01-01

    This study was conducted to evaluate the performance of 13 proprietary cold-mix patching materials, 4 of which are currently approved under a Virginia Department of Transportation (VDOT) Special Provision for High Quality Cold Patching Materials. Col...

  10. Living cardiac patch: the elixir for cardiac regeneration.

    PubMed

    Lakshmanan, Rajesh; Krishnan, Uma Maheswari; Sethuraman, Swaminathan

    2012-12-01

    A thorough understanding of the cellular and muscle fiber orientation in left ventricular cardiac tissue is of paramount importance for the generation of artificial cardiac patches to treat the ischemic myocardium. The major challenge faced during cardiac patch engineering is to choose a perfect combination of three entities; cells, scaffolds and signaling molecules comprising the tissue engineering triad for repair and regeneration. This review provides an overview of various scaffold materials, their mechanical properties and fabrication methods utilized in cardiac patch engineering. Stem cell therapies in clinical trials and the commercially available cardiac patch materials were summarized in an attempt to provide a recent perspective in the treatment of heart failure. Various tissue engineering strategies employed thus far to construct viable thick cardiac patches is schematically illustrated. Though many strategies have been proposed for fabrication of various cardiac scaffold materials, the stage and severity of the disease condition demands the incorporation of additional cues in a suitable scaffold material. The scaffold may be nanofibrous patch, hydrogel or custom designed films. Integration of stem cells and biomolecular cues along with the scaffold may provide the right microenvironment for the repair of unhealthy left ventricular tissue as well as promote its regeneration.

  11. Expedient Repair Materials for Roadway Pavements

    DTIC Science & Technology

    2005-03-01

    SILSPEC 900 PNS Patch/spall SSI Const. & Indus. Elastomeric conc. Matls Sikadur 22 Lo-Mod Sika Corp. Epoxy polymer concrete SikaTop 123 Plus Thin...patch Sika 2-component, polymer- 15 min modified Sikaset Roadway Patch Patch/spall Sika 1-comp. with high 15-25 min (15 min) (2000) alumina cement (not

  12. Development of a Remote External Repair Tool for Damaged or Defective Polyethylene Pipe

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kenneth H. Green; Willie E. Rochefort; Nick Wannenmacher

    2006-06-30

    Current procedures for repairing polyethylene (PE) gas pipe require excavation, isolation, and removal of the damaged section of pipe followed by fusing a new section of pipe into place. These techniques are costly and very disruptive. An alternative repair method was developed at Timberline Tool with support from Oregon State University (OSU) and funding by the U. S. Department of Energy National Energy Technology Laboratory (DOE/NETL). This project was undertaken to design, develop and test a tool and method for repairing damaged PE pipe remotely and externally in situ without squeezing off the flow of gas, eliminating the need formore » large-scale excavations. Through an iterative design and development approach, a final engineered prototype was developed that utilizes a unique thermo-chemical and mechanical process to apply a permanent external patch to repair small nicks, gouges and punctures under line pressure. The project identified several technical challenges during the design and development process. The repair tool must be capable of being installed under live conditions and operate in an 18-inch keyhole. This would eliminate the need for extensive excavations thus reducing the cost of the repair. Initially, the tool must be able to control the leak by encapsulating the pipe and apply slight pressure at the site of damage. Finally, the repair method must be permanent at typical operating pressures. The overall results of the project have established a permanent external repair method for use on damaged PE gas pipe in a safe and cost-effective manner. The engineered prototype was subjected to comprehensive testing and evaluation to validate the performance. Using the new repair tool, samples of 4-inch PE pipe with simulated damage were successfully repaired under line pressure to the satisfaction of DOE/NETL and the following natural gas companies: Northwest Natural; Sempra Energy, Southwest Gas Corporation, Questar, and Nicor. However, initial results of accelerated age testing on repaired pipe samples showed that the high density polyethylene (HDPE) pipe patch material developed a small crack at the high stress areas surrounding the patched hole within the first 48 hours of hot water testing, indicating that the patch material has a 25-year lifespan. Based on these results, further research is continuing to develop a stronger repair patch for a satisfactory 50-year patch system. Additional tests were also conducted to evaluate whether any of the critical performance properties of the PE pipe were reduced or compromised by the repair technique. This testing validated a satisfactory 50-year patch system for the pipe.« less

  13. Remote reactor repair: GTA (gas tungsten Arc) weld cracking caused by entrapped helium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kanne, Jr, W R

    1988-01-01

    A repair patch was welded to the wall of a nuclear reactor tank using remotely controlled thirty-foot long robot arms. Further repair was halted when gas tungsten arc (GTA) welds joining type 304L stainless steel patches to the 304 stainless steel wall developed toe cracks in the heat-affected zone (HAZ). The role of helium in cracking was investigated using material with entrapped helium from tritium decay. As a result of this investigation, and of an extensive array of diagnostic tests performed on reactor tank wall material, helium embrittlement was shown to be the cause of the toe cracks.

  14. MDOT innovation leading to faster, longer-lasting pavement repairs : research spotlight.

    DOT National Transportation Integrated Search

    2015-01-01

    Current methods of patching pavement must evolve to meet increasing mobility demands. : To address this need, MDOT has been testing a new generation of rapid set full-depth : pavement repair materials. Initial results are promising. The new materials...

  15. Modeling and Application of Piezoelectric Materials in Repair of Engineering Structures

    NASA Astrophysics Data System (ADS)

    Wu, Nan

    The shear horizontal wave propagation and vibration of piezoelectric coupled structures under an open circuit electrical boundary condition are studied. Following the studies on the dynamic response of piezoelectric coupled structures, the repair of both crack/notch and delaminated structures using piezoelectric materials are conducted. The main contribution was the proposed the active structural repair design using piezoelectric materials for different structures. An accurate model for the piezoelectric effect on the shear wave propagation is first proposed to guide the application of piezoelectric materials as sensors and actuators in the repair of engineering structures. A vibration analysis of a circular steel substrate surface bonded by a piezoelectric layer with open circuit is presented. The mechanical models and solutions for the wave propagation and vibration analysis of piezoelectric coupled structures are established based on the Kirchhoff plate model and Maxwell equation. Following the studies of the dynamic response of piezoelectric coupled structures, a close-loop feedback control repair methodology is proposed for a vibrating delaminated beam structure by using piezoelectric patches. The electromechanical characteristic of the piezoelectric material is employed to induce a local shear force above the delamination area via an external actuation voltage, which is designed as a feedback of the deflection of a vibrating beam and a delaminated plate, to reduce the stress singularity around the delamination tips. Furthermore, an experimental realization of an effective repair of a notched cantilever beam structure subjected to a dynamic loading by use of piezoelectric patches is reported. A small piezoelectric patch used as a sensor is placed on the notch position to monitor the severity of the stress singularity around the notch area by measuring the charge output on the sensor, and a patch used as an actuator is located around the notch area to generate a required bending moment by employing an actuation voltage to reduce the stress singularity at the notch position. The actuation voltage on the actuator is designed from a feedback circuit process. Through the analytical model, FEM simulation and experimental studies, the active structural repair method using piezoelectric materials is realized and proved to be feasible and practical.

  16. Planar biaxial testing of heart valve cusp replacement biomaterials: Experiments, theory and material constants.

    PubMed

    Labrosse, Michel R; Jafar, Reza; Ngu, Janet; Boodhwani, Munir

    2016-11-01

    Aortic valve (AV) repair has become an attractive option to correct aortic insufficiency. Yet, cusp reconstruction with various cusp replacement materials has been associated with greater long-term repair failures, and it is still unknown how such materials mechanically compare with native leaflets. We used planar biaxial testing to characterize six clinically relevant cusp replacement materials, along with native porcine AV leaflets, to ascertain which materials would be best suited for valve repair. We tested at least six samples of: 1) fresh autologous porcine pericardium (APP), 2) glutaraldehyde fixed porcine pericardium (GPP), 3) St Jude Medical pericardial patch (SJM), 4) CardioCel patch (CC), 5) PeriGuard (PG), 6) Supple PeriGuard (SPG) and 7) fresh porcine AV leaflets (PC). We introduced efficient displacement-controlled testing protocols and processing, as well as advanced convexity requirements on the strain energy functions used to describe the mechanical response of the materials under loading. The proposed experimental and data processing pipeline allowed for a robust in-plane characterization of all the materials tested, with constants determined for two Fung-like hyperelastic, anisotropic strain energy models. Overall, CC and SPG (respectively PG) patches ranked as the closest mechanical equivalents to young (respectively aged) AV leaflets. Because the native leaflets as well as CC, PG and SPG patches exhibit significant anisotropic behaviors, it is suggested that the fiber and cross-fiber directions of these replacement biomaterials be matched with those of the host AV leaflets. The long-term performance of cusp replacement materials would ideally be evaluated in large animal models for AV disease and cusp repair, and over several months or more. Given the unavailability and impracticality of such models, detailed information on stress-strain behavior, as studied herein, and investigations of durability and valve dynamics will be the best surrogates, as they have been for prosthetic valves. Overall, comparison with Fig. 3 suggests that CC and SPG (respectively PG) patches may be the closest mechanical equivalents to young (respectively aged) AV leaflets. Interestingly, the thicknesses of these materials are close to those reported for porcine and younger human AV leaflets, which may facilitate surgical implantation, by contrast to the thinner APP which has poor handling qualities. Because the native leaflets as well as CC, PG and SPG patches exhibit anisotropic behaviors, from a mechanistic perspective alone, it stands to reason that cardiac surgeons should seek to intraoperatively match the fiber and cross-fiber directions of these replacement biomaterials with those of the repaired AV leaflets. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  17. Numerical simulations of mechanical properties of innovative pothole patching materials featuring high toughness, low viscosity nano-molecular resins

    NASA Astrophysics Data System (ADS)

    Yuan, K. Y.; Yuan, W.; Ju, J. W.; Yang, J. M.; Kao, W.; Carlson, L.

    2012-04-01

    As asphalt pavements age and deteriorate, recurring pothole repair failures and propagating alligator cracks in the asphalt pavements have become a serious issue to our daily life and resulted in high repairing costs for pavement and vehicles. To solve this urgent issue, pothole repair materials with superior durability and long service life are needed. In the present work, revolutionary pothole patching materials with high toughness, high fatigue resistance that are reinforced with nano-molecular resins have been developed to enhance their resistance to traffic loads and service life of repaired potholes. In particular, DCPD resin (dicyclopentadiene, C10H12) with a Rhuthinium-based catalyst is employed to develop controlled properties that are compatible with aggregates and asphalt binders. In this paper, a multi-level numerical micromechanics-based model is developed to predict the mechanical properties of these innovative nanomolecular resin reinforced pothole patching materials. Coarse aggregates in the finite element analysis are modeled as irregular shapes through image processing techniques and randomly-dispersed coated particles. The overall properties of asphalt mastic, which consists of fine aggregates, asphalt binder, cured DCPD and air voids are theoretically estimated by the homogenization technique of micromechanics. Numerical predictions are compared with suitably designed experimental laboratory results.

  18. Evaluation of bonding agent application on concrete patch performance.

    DOT National Transportation Integrated Search

    2014-08-01

    The durability of partial depth repair is directly related to the bond strength between the repair material and existing : concrete. Bond strength development sensitivity to wait time with the use of bonding agents in partial depth repair was : inves...

  19. Pothole repair

    DOT National Transportation Integrated Search

    1999-11-01

    The primary objective of the pothole experiment was to determine which combinations of materials and patching procedures provide the most cost-effective repair of potholes in asphalt concrete-surfaced pavements. This technical summary summarizes the ...

  20. A New Absorbable Synthetic Substitute With Biomimetic Design for Dural Tissue Repair.

    PubMed

    Shi, Zhidong; Xu, Tao; Yuan, Yuyu; Deng, Kunxue; Liu, Man; Ke, Yiquan; Luo, Chengyi; Yuan, Tun; Ayyad, Ali

    2016-04-01

    Dural repair products are evolving from animal tissue-derived materials to synthetic materials as well as from inert to absorbable features; most of them lack functional and structural characteristics compared with the natural dura mater. In the present study, we evaluated the properties and tissue repair performance of a new dural repair product with biomimetic design. The biomimetic patch exhibits unique three-dimensional nonwoven microfiber structure with good mechanical strength and biocompatibility. The animal study showed that the biomimetic patch and commercially synthetic material group presented new subdural regeneration at 90 days, with low level inflammatory response and minimal to no adhesion formation detected at each stage. In the biological material group, no new subdural regeneration was observed and severe adhesion between the implant and the cortex occurred at each stage. In clinical case study, there was no cerebrospinal fluid leakage, and all the postoperation observations were normal. The biomimetic structure and proper rate of degradation of the new absorbable dura substitute can guide the meaningful reconstruction of the dura mater, which may provide a novel approach for dural defect repair. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  1. A field investigation of concrete patches containing pyrament blended concrete.

    DOT National Transportation Integrated Search

    1994-01-01

    During roadway repairs, state highway officials try to minimize lane closure times. This reduces inconvenience to travelers, reduces traffic control needs, and helps minimize work zone accidents. For rapid repairs, materials that provide high early s...

  2. Portland cement concrete (PCC) partial-depth spall repair

    DOT National Transportation Integrated Search

    1999-11-01

    The primary aim of the partial-depth spall repair study was to determine the most effective and economical materials and procedures for placing quality, long-lasting partial-depth patches in jointed concrete pavements. A secondary objective of the st...

  3. A study of tensile residual strength of composite laminates under different patch-repaired series

    NASA Astrophysics Data System (ADS)

    Ding, M. H.; zhan, S.; Tang, Y. H.; Wang, L.; Ma, D. Q.; Wang, R. G.

    2017-09-01

    The tensile behavior of composite laminate structures repaired by bonding external patches was studied in the paper. Two different types of patches including wedge patches and inverted wedge patches were used and failure mechanisms, failure load and strength predictions were studied. A convenient and fast method of building 2-D finite element modeling (FEM) of laminate structure repaired was proposed and the strength of repaired laminate structures was calculated by FEM. The results showed that more than 80% tensile strength of the undamaged laminate could be recovered by bonding patch repairs. Moreover, the results indicated that the strength of inverted wedge patches repair were higher than that of wedge patches repair. FEM simulation results indicated that high stress concentration was found along the edges of invert patches and the most weakness part located in the adhesive bondline. FEM analysis results showed that the strength predicted matched well with the test strength.

  4. Biodegradable materials for surgical management of infective endocarditis: new solution or a dead end street?

    PubMed

    Myers, Patrick O; Cikirikcioglu, Mustafa; Kalangos, Afksendiyos

    2014-08-03

    One third of patients with infective endocarditis will require operative intervention. Given the superiority of valve repair over valve replacement in many indications other than endocarditis, there has been increasing interest and an increasing number of reports of excellent results of valve repair in acute infective endocarditis. The theoretically ideal material for valve repair in this setting is non-permanent, "vanishing" material, not at risk of seeding or colonization. The goal of this contribution is to review currently available data on biodegradable materials for valve repair in infective endocarditis. Rigorous electronic and manual literature searches were conducted to identify reports of biodegradable materials for valve repair in infective endocarditis. Articles were identified in electronic database searches of Medline, Embase and the Cochrane Library, using a predetermined search strategy. 49 manuscripts were included in the review. Prosthetic materials needed for valve repair can be summarized into annuloplasty rings to remodel the mitral or tricuspid annulus, and patch materials to replace resected valvar tissue. The commercially available biodegradable annuloplasty ring has shown interesting clinical results in a single-center experience; however further data is required for validation and longer follow-up. Unmodified extra-cellular matrix patches, such as small intestinal submucosa, have had promising initial experimental and clinical results in non-infected valve repair, although in valve repair for endocarditis has been reported in only one patient, and concerns have been raised regarding their mechanical stability in an infected field. These evolving biodegradable devices offer the potential for valve repair with degradable materials replaced with autologous tissue, which could further improve the results of valve repair for infective endocarditis. This is an evolving field with promising experimental or initial clinical results, however long-term outcomes are lacking and further data is necessary to validate this theoretically interesting approach to infective endocarditis.

  5. Biodegradable materials for surgical management of infective endocarditis: new solution or a dead end street?

    PubMed Central

    2014-01-01

    Background One third of patients with infective endocarditis will require operative intervention. Given the superiority of valve repair over valve replacement in many indications other than endocarditis, there has been increasing interest and an increasing number of reports of excellent results of valve repair in acute infective endocarditis. The theoretically ideal material for valve repair in this setting is non-permanent, “vanishing” material, not at risk of seeding or colonization. The goal of this contribution is to review currently available data on biodegradable materials for valve repair in infective endocarditis. Discussion Rigorous electronic and manual literature searches were conducted to identify reports of biodegradable materials for valve repair in infective endocarditis. Articles were identified in electronic database searches of Medline, Embase and the Cochrane Library, using a predetermined search strategy. 49 manuscripts were included in the review. Prosthetic materials needed for valve repair can be summarized into annuloplasty rings to remodel the mitral or tricuspid annulus, and patch materials to replace resected valvar tissue. The commercially available biodegradable annuloplasty ring has shown interesting clinical results in a single-center experience; however further data is required for validation and longer follow-up. Unmodified extra-cellular matrix patches, such as small intestinal submucosa, have had promising initial experimental and clinical results in non-infected valve repair, although in valve repair for endocarditis has been reported in only one patient, and concerns have been raised regarding their mechanical stability in an infected field. Summary These evolving biodegradable devices offer the potential for valve repair with degradable materials replaced with autologous tissue, which could further improve the results of valve repair for infective endocarditis. This is an evolving field with promising experimental or initial clinical results, however long-term outcomes are lacking and further data is necessary to validate this theoretically interesting approach to infective endocarditis. PMID:25087015

  6. Handbook for Repairing Nonconventional Roofing Systems

    DTIC Science & Technology

    1988-12-01

    membrane. 61 PIMB (solvent) Figure 71. Apply welding solvent to the PIB patch. Figure 72. Work the solvent Into the P113 patch. Pila 62 (solvent) Figure 73...when exposed to flame but will not burn nor support combustion . PVC repair techniques are basically the same as for a new application of a PVC fully...granules (if desired) before the final coat dries. 83 PUF F4gue 102. Remove the damaged material and bevel the s! des of the hole. 4󈧵, Figure 103. Trim th

  7. The effectiveness of an adhesively bonded composite patch repair as applied to a transport aircraft lower wing skin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ruschau, J.J.; Coate, J.E.

    1996-12-31

    Specimens were machined from lower wing skin extrusions of a transport aircraft, precracked under fatigue loading, repaired with a boron/epoxy patch, and subsequently fatigue tested under simulated flight loading conditions to evaluate the effectiveness of an adhesively bonded repair patch. Testing was performed at RT and -54{degrees}C for two configurations: one with the crack running up the integral stiffener (riser), the other running down the riser towards the outer skin surface. Cracks were initiated from a single 6.35 mm diameter hole located in the riser portion of the 7075-T6 wing skin material. Ultrasonic inspections were performed during fatigue loading tomore » determine crack growth and damage underneath the patch. Limited results show the adhesively bonded patch was successful in stopping or greatly reducing any further crack growth. Under laboratory air conditions, no crack growth occurred following 30,000 equivalent flight hours, double the expected life of the patched structure. Similarly at -54{degrees}C, no crack growth was observed for a patched crack growing up the riser following 15,000 EFH. For the case of a crack growing down the riser at the lower test temperature, some crack growth was measured, though at a greatly reduced rate.« less

  8. Engineering properties of brittle repair materials : summary report.

    DOT National Transportation Integrated Search

    1992-09-01

    Most codes of practice prescribe procedures for selecting patch configuration and materials based on test devised for evaluating new pavement materials. This study is aimed at examining the special consideration to be given to such evaluation procedu...

  9. Structural Technology and Analysis Program (STAP) Delivery Order 0004: Durability Patch

    NASA Astrophysics Data System (ADS)

    Ikegami, Roy; Haugse, Eric; Trego, Angela; Rogers, Lynn; Maly, Joe

    2001-06-01

    Structural cracks in secondary structure, resulting from a high cycle fatigue (HCF) environment, are often referred to as nuisance cracks. This type of damage can result in costly inspections and repair. The repairs often do not last long because the repaired structure continues to respond in a resonant fashion to the environment. Although the use of materials for passive damping applications is well understood, there are few applications to high-cycle fatigue problems. This is because design information characterization temperature, resonant response frequency and strain levels are difficult to determine. The Durability Patch and Damage Dosimeter Program addressed these problems by: (1) Developing a damped repair design process which includes a methodology for designing the material and application characteristics required to optimally damp the repair. (2) Designing and developing a rugged, small, and lightweight data acquisition unit called the damage dosimeter. This is a battery operated, single board computer, capable of collecting three channels of strain and one channel of temperature, processing this data by user developed algorithms written in the C programming language, and storing the processed data in resident memory. The dosimeter is used to provide flight data needed to characterize the vibration environment. The vibration environment is then used to design the damping material characteristics and repair. The repair design methodology and dosimeter were demonstrated on B-52, C-130, and F-15 aircraft applications.

  10. Engineering properties of brittle repair materials : final report : volume I.

    DOT National Transportation Integrated Search

    1992-09-01

    Most codes of practice prescribe procedures for selecting patch configuration and materials based on tests devised for evaluating new pavement materials. This study is aimed at examining the special consideration to be given to such evaluation proced...

  11. Engineering properties of brittle repair materials : final report : volume II.

    DOT National Transportation Integrated Search

    1992-09-01

    Most codes of practice prescribe procedures for selecting patch configuration and materials based on tests devised for evaluating new pavement materials. This study is aimed at examining the special consideration to be given to such evaluation proced...

  12. Structural Repair of Steel Piping by In-Situ Sleeving of Nanostructured Materials

    DOT National Transportation Integrated Search

    2009-06-03

    The focus of Task 1 is to demonstrate the repair of degraded pipeline steel using patches of high strength nanocrystalline metal. As mentioned in Bi-Monthly Research Progress Report #2, the cracking caused by corrosion damage in the steel pipe sectio...

  13. Development of a Hard-Patch Approach for Scarf Repair of Composite Structure

    DTIC Science & Technology

    2006-06-01

    composite skins are bonded to a Ti- 6Al - 4V titanium alloy splice plate. The inboard and outboard ribs are also made of this alloy, as is the root rib which...operation. Options for the patch material include composite laminate, titanium alloy sheet laminate or solid titanium alloy. d) Semi-Hard Patch – The...patch is manufactured from a series of pre-cured composite laminates each containing several plies or titanium sheets, which are interleaved with

  14. Prediction of Fatigue Crack Growth of Repaired Al-alloy Structures with Double Sides

    NASA Astrophysics Data System (ADS)

    Benachour, M.; Benachour, N.; Benguediab, M.; Seriari, F. Z.

    During navigation, aircrafts are subject to fatigue damage. In order to rehabilitate damaged structures some techniques are often used to resolve this problem. Efficient repair technique, called composite patch repair, was used to reinforce the damaged structures and stop cracks. In this paper, effect of composite patch repair (Boron/Epoxy) on fatigue crack growth (FCG) was investigated on 2219 T62 Al-alloy. Effects of double patch repair in single notch tensile specimen (SENT) on FCG were studied and compared to single patch repair. Results show beneficial effect of patch repair on fatigue life and FCGR in comparison with the un-patched specimen. In addition, effect of mean stress characterized by stress ratio was highlighted. Fatigue behavior of investigated Al-alloy was compared.

  15. Product evaluation : Thoro product demonstration

    DOT National Transportation Integrated Search

    1986-07-18

    This report contains a product evaluation of Thoro System's "Roadpatch" and "Thorite". Roadpatch is a cement base, fast-setting patching material. The material is fortified with special alkali resistant glass fibers. It is designed to repair potholes...

  16. Rotator cuff repair with a tendon-fibrocartilage-bone composite bridging patch.

    PubMed

    Ji, Xiaoxi; Chen, Qingshan; Thoreson, Andrew R; Qu, Jin; An, Kai-Nan; Amadio, Peter C; Steinmann, Scott P; Zhao, Chunfeng

    2015-11-01

    To compare the mechanical performance of a rotator cuff repaired with a novel tendon-fibrocartilage-bone composite bridging patch vs the traditional Mason-Allen repair in an in vitro canine model. Twenty shoulders and 10 bridging patches from patellar tendon were harvested. The patches were trimmed and sliced into 2 layers. An infraspinatus tendon tear was created in each shoulder. Modified Mason-Allen sutures were used to repair the infraspinatus tendon to the greater tuberosity, with or without the bridging patch (bridging patch group and controls, respectively). Shoulders were loaded to failure under displacement control at a rate of 0.5mm/s. The ultimate tensile load was significantly higher in the bridging patch group than control (mean [SD], 365.46 [36.45] vs 272.79 [48.88] N; P<.001). Stiffness at the greater tuberosity repair site and the patch-infraspinatus tendon repair site was significantly higher than the control repair site (93.96 [27.72] vs 42.62 [17.48] N/mm P<.001; 65.94 [24.51] vs 42.62 [17.48] N/mm P=.02, respectively). The tendon-fibrocartilage-bone composite bridging patch achieved higher ultimate tensile load and stiffness at the patch-greater tuberosity repair site compared with traditional repair in a canine model. This composite tissue transforms the traditional tendon-to-bone healing interface (with dissimilar tissues) into a pair of bone-to-bone and tendon-to-tendon interfaces, which may improve healing quality and reduce retear rate. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Laparoscopic repair of perforated peptic ulcer: patch versus simple closure.

    PubMed

    Abd Ellatif, M E; Salama, A F; Elezaby, A F; El-Kaffas, H F; Hassan, A; Magdy, A; Abdallah, E; El-Morsy, G

    2013-01-01

    Laparoscopic correction of perforated peptic ulcer (PPU) has become an accepted way of management. Patch omentoplasty stayed for decades the main method of repair. The goal of the present study was to evaluate whether laparoscopic simple repair of PPU is as safe as patch omentoplasty. Since June 2005, 179 consecutive patients of PPU were treated by laparoscopic repair at our centers. We conducted a retrospective chart review in December 2012. Group I (patch group) included patients who were treated with standard patch omentoplasty. Group II (non-patch group) included patients who received simple repair without patch. From June 2007 to Dec. 2012, 179 consecutive patients of PPU who were treated by laparoscopic repair at our centers were enrolled in this multi-center retrospective study. 108 patients belong to patch group. While 71 patients were treated with laparoscopic simple repair. Operative time was significantly shorter in group II (non patch) (p = 0.01). No patient was converted to laparotomy. There was no difference in age, gender, ASA score, surgical risk (Boey's) score, and incidence of co-morbidities. Both groups were comparable in terms of hospital stay, time to resume oral intake, postoperative complications and surgical outcomes. Laparoscopic simple repair of PPU is a safe procedure compared with the traditional patch omentoplasty in presence of certain selection criteria. Copyright © 2013 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  18. Sealing Materials for Use in Vacuum at High Temperatures

    NASA Technical Reports Server (NTRS)

    Pettit, Donald R.; Camarda, Charles J.; Lee Vaughn, Wallace

    2012-01-01

    Sealing materials that can be applied and left in place in vacuum over a wide range of temperatures (especially temperatures of a few thousand degrees Celsius) have been conceived and investigated for potential utility in repairing thermal-protection tiles on the space shuttles in orbit before returning to Earth. These materials are also adaptable to numerous terrestrial applications that involve vacuum processing and/or repair of structures that must withstand high temperatures. These materials can be formulated to have mechanical handling characteristics ranging from almost freely flowing liquid-like consistency through paste-like consistency to stiff puttylike consistency, and to retain these characteristics in vacuum until heated to high curing temperatures. A sealing material of this type can be formulated to be used in any of several different ways for example, to be impregnated into a high-temperature-fabric patch, impregnated into a high-temperature-fabric gasket for sealing a patch, applied under a patch, or applied alone in the manner of putty or wallboard compound. The sealing material must be formulated to be compatible with, and adhere to, the structural material(s) to be repaired. In general, the material consists of a vacuum-compatible liquid containing one or more dissolved compound(s) and/or mixed with suspended solid particles. Depending on the intended application, the liquid can be chosen to be of a compound that can remain in place in vacuum for a time long enough to be useful, and/or to evaporate or decompose in a controlled way to leave a useful solid residue behind. The evaporation rate is determined by proper choice of vapor pressure, application of heat, and/or application of ultraviolet light or other optical radiation. The liquid chosen for the original space shuttle application is a commercial silicone vacuum-pump oil.

  19. Transplantation of mesenchymal stem cells cultured on biomatrix support induces repairing of digestive tract defects, in animal model.

    PubMed

    Sîrbu-Boeţi, Mirela-Patricia; Chivu, Mihaela; Pâslaru, Liliana Livia; Efrimescu, C; Herlea, V; Pecheanu, C; Moldovan, Lucia; Dragomir, Laura; Bleotu, Coralia; Ciucur, Elena; Vidulescu, Cristina; Vasilescu, Mihaela; Boicea, Anişoara; Mănoiu, S; Ionescu, M I; Popescu, I

    2009-01-01

    Transplanted mesenchymal stem cells (MSCs) appear to play a significant role in adult tissue repair. The aim of this research was to obtain MSCs enriched, three dimensional (3D) patches for transplant, and to test their ability to induce repair of iatrogenic digestive tract defects in rats. MSCs were obtained from human and rat bone marrow, cultured in vitro, and seeded in a collagen-agarose scaffold, where they showed enhanced viability and proliferation. The phenotype of the cultured cells was representative for MSCs (CD105+, CD90+, and CD34-, CD45-, CD3-, CD14-). The 3D patch was obtained by laying the MSCs enriched collagen-agarose scaffold on a human or swine aortic fragment. After excision of small portions of the rat digestive tract, the 3D patches were sutured at the edge of the defect using micro-surgical techniques. The rats were sacrificed at time-points and the regeneration of the digestive wall was investigated by immunofluorescence, light and electron microscopy. The MSCs enriched 3D patches were biocompatible, biodegradable, and prompted the regeneration of the four layers of the stomach and intestine wall in rats. Human cells were identified in the rat regenerated digestive wall as a hallmark of the transplanted MSCs. For the first time we constructed 3D patches made of cultured bone marrow MSCs, embedded into a collagen-rich biomatrix, on vascular bio-material support, and transplanted them in order to repair iatrogenic digestive tract defects. The result was a complete repair with preservation of the four layered structure of the digestive wall.

  20. Rotator Cuff Repair with a Tendon-Fibrocartilage-Bone Composite Bridging Patch

    PubMed Central

    Ji, Xiaoxi; Chen, Qingshan; Thoreson, Andrew R.; Qu, Jin; An, Kai-Nan; Amadio, Peter C.; Steinmann, Scott P.; Zhao, Chunfeng

    2015-01-01

    Background To compare the mechanical performance of a rotator cuff repaired with a novel tendon-fibrocartilage-bone composite bridging patch vs the traditional Mason-Allen repair in an in vitro canine model. Methods Twenty shoulders and 10 bridging patches from patellar tendon were harvested. The patches were trimmed and sliced into 2 layers. An infraspinatus tendon tear was created in each shoulder. Modified Mason-Allen sutures were used to repair the infraspinatus tendon to the greater tuberosity, with or without the bridging patch (bridging patch group and controls, respectively). Shoulders were loaded to failure under displacement control at a rate of 0.5mm/sec. Findings The ultimate tensile load was significantly higher in the bridging patch group than control (mean [SD], 365.46 [36.45] vs 272.79 [48.88] N; P<.001). Stiffness at the greater tuberosity repair site and the patch-infraspinatus tendon repair site was significantly higher than the control repair site (93.96 [27.72] vs 42.62 [17.48] N/mm P<.001; 65.94 [24.51] vs 42.62 [17.48] N/mm P=.02, respectively). Interpretation The tendon-fibrocartilage-bone composite bridging patch achieved higher ultimate tensile load and stiffness at the patch–greater tuberosity repair site compared with traditional repair in a canine model. This composite tissue transforms the traditional tendon-to-bone healing interface (with dissimilar tissues) into a pair of bone-to-bone and tendon-to-tendon interfaces, which may improve healing quality and reduce retear rate. PMID:26190097

  1. Is Decellularized Porcine Small Intestine Sub-mucosa Patch Suitable for Aortic Arch Repair?

    PubMed Central

    Corno, Antonio F.; Smith, Paul; Bezuska, Laurynas; Mimic, Branko

    2018-01-01

    Introduction: We reviewed our experience with decellularized porcine small intestine sub-mucosa (DPSIS) patch, recently introduced for congenital heart defects. Materials and Methods: Between 10/2011 and 04/2016 a DPSIS patch was used in 51 patients, median age 1.1 months (5 days to 14.5 years), for aortic arch reconstruction (45/51 = 88.2%) or aortic coarctation repair (6/51 = 11.8%). All medical records were retrospectively reviewed, with primary endpoints interventional procedure (balloon dilatation) or surgery (DPSIS patch replacement) due to patch-related complications. Results: In a median follow-up time of 1.5 ± 1.1 years (0.6–2.3years) in 13/51 patients (25.5%) a re-intervention, percutaneous interventional procedure (5/51 = 9.8%) or re-operation (8/51 = 15.7%) was required because of obstruction in the correspondence of the DPSIS patch used to enlarge the aortic arch/isthmus, with median max velocity flow at Doppler interrogation of 4.0 ± 0.51 m/s. Two patients required surgery after failed interventional cardiology. The mean interval between DPSIS patch implantation and re-intervention (percutaneous procedure or re-operation) was 6 months (1–17 months). While there were 3 hospital deaths (3/51 = 5.9%) not related to the patch implantation, no early or late mortality occurred for the subsequent procedure required for DPSIS patch interventional cardiology or surgery. The median max velocity flow at Doppler interrogation through the aortic arch/isthmus for the patients who did not require interventional procedure or surgery was 1.7 ± 0.57 m/s. Conclusions: High incidence of re-interventions with DPSIS patch for aortic arch and/or coarctation forced us to use alternative materials (homografts and decellularized gluteraldehyde preserved bovine pericardial matrix). PMID:29900163

  2. Application of the bridged crack model for evaluation of materials repairing and self-healing

    NASA Astrophysics Data System (ADS)

    Perelmuter, M.

    2017-12-01

    The bridged crack model is used for analysis of repairing and self-healing of cracked structures. Material repairing is treated as insertions of external ligaments into cracks or placement of the reinforcing patches over cracks. Bonds destruction and regeneration at the crack bridged zone is evaluated by the thermo-fluctuation kinetic theory. The healing time is dependent on the chemical reaction rate of the healing agent, the crack size and the external loads. The decreasing of the stress intensity factors is used as the measure of the repairing and healing effects. The mathematical background of the problem solution is based on the methods of the singular integral-differential equations. The model can be used for the evaluation of composite materials durability.

  3. Surgery for left ventricular aneurysm: early and late survival after simple linear repair and endoventricular patch plasty.

    PubMed

    Lundblad, Runar; Abdelnoor, Michel; Svennevig, Jan Ludvig

    2004-09-01

    Simple linear resection and endoventricular patch plasty are alternative techniques to repair postinfarction left ventricular aneurysm. The aim of the study was to compare these 2 methods with regard to early mortality and long-term survival. We retrospectively reviewed 159 patients undergoing operations between 1989 and 2003. The epidemiologic design was of an exposed (simple linear repair, n = 74) versus nonexposed (endoventricular patch plasty, n = 85) cohort with 2 endpoints: early mortality and long-term survival. The crude effect of aneurysm repair technique versus endpoint was estimated by odds ratio, rate ratio, or relative risk and their 95% confidence intervals. Stratification analysis by using the Mantel-Haenszel method was done to quantify confounders and pinpoint effect modifiers. Adjustment for multiconfounders was performed by using logistic regression and Cox regression analysis. Survival curves were analyzed with the Breslow test and the log-rank test. Early mortality was 8.2% for all patients, 13.5% after linear repair and 3.5% after endoventricular patch plasty. When adjusted for multiconfounders, the risk of early mortality was significantly higher after simple linear repair than after endoventricular patch plasty (odds ratio, 4.4; 95% confidence interval, 1.1-17.8). Mean follow-up was 5.8 +/- 3.8 years (range, 0-14.0 years). Overall 5-year cumulative survival was 78%, 70.1% after linear repair and 91.4% after endoventricular patch plasty. The risk of total mortality was significantly higher after linear repair than after endoventricular patch plasty when controlled for multiconfounders (relative risk, 4.5; 95% confidence interval, 2.0-9.7). Linear repair dominated early in the series and patch plasty dominated later, giving a possible learning-curve bias in favor of patch plasty that could not be adjusted for in the regression analysis. Postinfarction left ventricular aneurysm can be repaired with satisfactory early and late results. Surgical risk was lower and long-term survival was higher after endoventricular patch plasty than simple linear repair. Differences in outcome should be interpreted with care because of the retrospective study design and the chronology of the 2 repair methods.

  4. Experimental Fatigue Study of Composite Patch Repaired Steel Plates with Cracks

    NASA Astrophysics Data System (ADS)

    Karatzas, Vasileios A.; Kotsidis, Elias A.; Tsouvalis, Nicholas G.

    2015-10-01

    Cracks are among the most commonly encountered defects in metallic structures operating at sea. Composite patch repairing is a repair method which is gaining popularity as it counters most of the problems faced by conventional renewal repairs. Extensive studies can be found in the literature addressing the efficiency of this novel repair method using techniques which meet higher performance and monitoring standards than these commonly found in naval applications. In this work the efficiency of practices widely used in the ship repair industry for the implementation of composite patch repairing is addressed. To this end, steel plates repaired with composite patches were tested under fatigue loading. The composite patches consisted of carbon fibers in epoxy matrix and were directly laminated to the steel surface using the vacuum infusion method. Two different surface preparation methods, namely grit-blasting and mechanical treatment with the use of a needle gun were studied. In addition, in order to account for the harsh environmental conditions during the operating life of the structure and to study its effect on the repair, two different aging scenarios were considered. Non-destructive evaluation of the patches was performed so as to assess the quality of the repair, and the evolution of debonding during testing.

  5. Light-Curing Adhesive Repair Tapes

    NASA Technical Reports Server (NTRS)

    Allred, Ronald; Haight, Andrea Hoyt

    2009-01-01

    Adhesive tapes, the adhesive resins of which can be cured (and thereby rigidized) by exposure to ultraviolet and/or visible light, are being developed as repair patch materials. The tapes, including their resin components, consist entirely of solid, low-outgassing, nonhazardous or minimally hazardous materials. They can be used in air or in vacuum and can be cured rapidly, even at temperatures as low as -20 C. Although these tapes were originally intended for use in repairing structures in outer space, they can also be used on Earth for quickly repairing a wide variety of structures. They can be expected to be especially useful in situations in which it is necessary to rigidize tapes after wrapping them around or pressing them onto the parts to be repaired.

  6. Patch-augmented rotator cuff repair: influence of the patch fixation technique on primary biomechanical stability.

    PubMed

    Jung, Christian; Spreiter, Gregor; Audigé, Laurent; Ferguson, Stephen J; Flury, Matthias

    2016-05-01

    There is an ongoing debate about the potential of patch augmentation to improve biomechanical stability and healing associated with rotator cuff repair. The biomechanical properties of three different patch-augmented rotator cuff repair techniques were assessed in vitro and compared with a standard repair. Dermal collagen patch augmentation may increase the primary stability and strength of the repaired tendon in vitro, depending on the technique used for patch application. Forty cadaveric sheep shoulders with dissected infraspinatus tendons were randomized into four groups (n = 10/group) for tendon repair using a knotless double-row suture anchor technique. A xenologous dermal extracellular matrix patch was used for augmentation in the three test groups using an "integrated", "cover", or "hybrid" technique. Tendons were preconditioned, cyclically loaded from 10 to 30 N at 1 Hz, and then loaded monotonically to failure. Biomechanical properties and the mode of failure were evaluated. Patch augmentation significantly increased the maximum load at failure by 61 % in the "cover" technique test group (225.8 N) and 51 % in the "hybrid" technique test group (211.4 N) compared with the non-augmented control group (140.2 N) (P ≤ 0.015). For the test group with "integrated" patch augmentation, the load at failure was 28 % lower (101.6 N) compared with the control group (P = 0.043). There was no significant difference in initial and linear stiffness among the four experimental groups. The most common mode of failure was tendon pullout. No anchor dislocation, patch disruption or knot breakage was observed. Additional patch augmentation with a collagen patch influences the biomechanical properties of a rotator cuff repair in a cadaveric sheep model. Primary repair stability can be significantly improved depending on the augmentation technique.

  7. Selective versus routine patch metal allergy testing to select bar material for the Nuss procedure in 932 patients over 10years.

    PubMed

    Obermeyer, Robert J; Gaffar, Sheema; Kelly, Robert E; Kuhn, M Ann; Frantz, Frazier W; McGuire, Margaret M; Paulson, James F; Kelly, Cynthia S

    2018-02-01

    The aim of the study was to determine the role of patch metal allergy testing to select bar material for the Nuss procedure. An IRB-approved (11-04-WC-0098) single institution retrospective, cohort study comparing selective versus routine patch metal allergy testing to select stainless steel or titanium bars for Nuss repair was performed. In Cohort A (9/2004-1/2011), selective patch testing was performed based on clinical risk factors. In Cohort B (2/2011-9/2014), all patients were patch tested. The cohorts were compared for incidence of bar allergy and resultant premature bar loss. Risk factors for stainless steel allergy or positive patch test were evaluated. Cohort A had 628 patients with 63 (10.0%) selected for patch testing, while all 304 patients in Cohort B were tested. Over 10years, 15 (1.8%) of the 842 stainless steel Nuss repairs resulted in a bar allergy, and 5 had a negative preoperative patch test. The incidence of stainless steel bar allergy (1.8% vs 1.7%, p=0.57) and resultant bar loss (0.5% vs 1.3%, p=0.23) was not statistically different between cohorts. An allergic reaction to a stainless steel bar or a positive patch test was more common in females (OR=2.3, p<0.001) and patients with a personal (OR=24.8, p<0.001) or family history (OR=3.1, p<0.001) of metal sensitivity. Stainless steel bar allergies occur at a low incidence with either routine or selective patch metal allergy testing. If selective testing is performed, it is advisable in females and patients with a personal or family history of metal sensitivity. A negative preoperative patch metal allergy test does not preclude the possibility of a postoperative stainless steel bar allergy. Level III Treatment Study and Study of Diagnostic Test. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Rapid road repair vehicle

    DOEpatents

    Mara, Leo M.

    1998-01-01

    Disclosed is a rapid road repair vehicle capable of moving over a surface to be repaired at near normal posted traffic speeds to scan for and find an the high rate of speed, imperfections in the pavement surface, prepare the surface imperfection for repair by air pressure and vacuum cleaning, applying a correct amount of the correct patching material to effect the repair, smooth the resulting repaired surface, and catalog the location and quality of the repairs for maintenance records of the road surface. The rapid road repair vehicle can repair surface imperfections at lower cost, improved quality, at a higher rate of speed than was was heretofor possible, with significantly reduced exposure to safety and health hazards associated with this kind of road repair activities in the past.

  9. Rapid road repair vehicle

    DOEpatents

    Mara, L.M.

    1998-05-05

    Disclosed is a rapid road repair vehicle capable of moving over a surface to be repaired at near normal posted traffic speeds to scan for and find at the high rate of speed, imperfections in the pavement surface, prepare the surface imperfection for repair by air pressure and vacuum cleaning, applying a correct amount of the correct patching material to effect the repair, smooth the resulting repaired surface, and catalog the location and quality of the repairs for maintenance records of the road surface. The rapid road repair vehicle can repair surface imperfections at lower cost, improved quality, at a higher rate of speed than was not heretofor possible, with significantly reduced exposure to safety and health hazards associated with this kind of road repair activities in the past. 2 figs.

  10. Composite Structures Repair Development at Kennedy Space Center

    NASA Technical Reports Server (NTRS)

    Cox, Sarah B.

    2015-01-01

    This presentation discusses the development and results of composite patch repair perfromed at Kennedy Space Center. This includes impact damage, patch repair methods, nondestructive evaluation, and edgewise compression testing.

  11. Investigation on laser-assisted tissue repair with NIR millisecond-long light pulses and Indocyanine Green-biopolymeric patches

    NASA Astrophysics Data System (ADS)

    Matteini, Paolo; Banchelli, Martina; Cottat, Maximilien; Osticioli, Iacopo; de Angelis, Marella; Rossi, Francesca; Pini, Roberto

    2016-03-01

    In previous works a minimally invasive laser-assisted technique for vascular repair was presented. The technique rests on the photothermal adhesion of a biocompatible and bioresorbable patch containing Indocyanine Green that is brought into contact with the site to be repaired. Afterward the use of NIR millisecond-long light pulses generates a strong welding effect between the patch and the underlying tissue and in turn the repair of the wound. This technique was shown to be effective in animal model and provides several advantages over conventional suturing methods. Here we investigate and discuss the optical stability of the ICG-biopolymeric patches and the photothermal effects induced to the irradiated tissue.

  12. A smart composite patch for the repair of aircraft structures

    NASA Astrophysics Data System (ADS)

    Wakha, Kelah; Samuel, Paul; Pines, Darryll J.

    2005-05-01

    Recent interest in bonded composite patch repair technology for aerospace systems is because this method can be carried out at a reduced cost and time and can easily be applied to complex geometric structures. This paper details the development of a dual stiffness/energy sensor for monitoring the integrity of a composite patch used to repair an aluminum structural component. The smart sensor has the ability to predict the elastic field of a given host structure based on the strain state of two sub-sensors integrated into the structure. The present study shows the possibility of using the sensor to deduce the local instantaneous host stiffness. Damaged structures are characterized by a reduction in their elastic stiffness that evolve from microstructural defects. A local smart sensor can be developed to sense the local average properties on a host. In this paper, sensors are attached to a structure and a modified Eshelby's equivalent inclusion method is used to derive the elastic properties of the host. An analytical derivation and a sensitivity analysis for the quasistatic application is given in a papers by Majed, Dasgupta, Kelah and Pines. A summary of the derivation of the dynamic Eshelby tensor is presented. This is of importance because damage detection in structures undergoing vibratory and other motions present a greater challenge than those in quasistatic motion. An in-situ health monitoring active sensor system for a real structure (an aluminum plate with an attached repair patch) under close-to real lifecycle loading conditions is developed. The detection of the onset of any damage to the structure as well as the repair patch and the subsequent monitoring of the growth of this damage constitute important goals of the system. Both experimental and finite element methods were applied. Experimental results are presented for tests of the aluminum plate with the repair patch under monotonic quasi-static and dynamic loading vibratory conditions. In summary, the study shows that smart bonded composite repair patches are very effective in the repair of thin aluminum structures since they are able to determine the integrity of the repair structure as well as the repair patch.

  13. Advanced optimal design concepts for composite material aircraft repair

    NASA Astrophysics Data System (ADS)

    Renaud, Guillaume

    The application of an automated optimization approach for bonded composite patch design is investigated. To do so, a finite element computer analysis tool to evaluate patch design quality was developed. This tool examines both the mechanical and the thermal issues of the problem. The optimized shape is obtained with a bi-quadratic B-spline surface that represents the top surface of the patch. Additional design variables corresponding to the ply angles are also used. Furthermore, a multi-objective optimization approach was developed to treat multiple and uncertain loads. This formulation aims at designing according to the most unfavorable mechanical and thermal loads. The problem of finding the optimal patch shape for several situations is addressed. The objective is to minimize a stress component at a specific point in the host structure (plate) while ensuring acceptable stress levels in the adhesive. A parametric study is performed in order to identify the effects of various shape parameters on the quality of the repair and its optimal configuration. The effects of mechanical loads and service temperature are also investigated. Two bonding methods are considered, as they imply different thermal histories. It is shown that the proposed techniques are effective and inexpensive for analyzing and optimizing composite patch repairs. It is also shown that thermal effects should not only be present in the analysis, but that they play a paramount role on the resulting quality of the optimized design. In all cases, the optimized configuration results in a significant reduction of the desired stress level by deflecting the loads away from rather than over the damage zone, as is the case with standard designs. Furthermore, the automated optimization ensures the safety of the patch design for all considered operating conditions.

  14. Bonded repair of composite aircraft structures: A review of scientific challenges and opportunities

    NASA Astrophysics Data System (ADS)

    Katnam, K. B.; Da Silva, L. F. M.; Young, T. M.

    2013-08-01

    Advanced composite materials have gained popularity in high-performance structural designs such as aerospace applications that require lightweight components with superior mechanical properties in order to perform in demanding service conditions as well as provide energy efficiency. However, one of the major challenges that the aerospace industry faces with advanced composites - because of their inherent complex damage behaviour - is structural repair. Composite materials are primarily damaged by mechanical loads and/or environmental conditions. If material damage is not extensive, structural repair is the only feasible solution as replacing the entire component is not cost-effective in many cases. Bonded composite repairs (e.g. scarf patches) are generally preferred as they provide enhanced stress transfer mechanisms, joint efficiencies and aerodynamic performance. With an increased usage of advanced composites in primary and secondary aerospace structural components, it is thus essential to have robust, reliable and repeatable structural bonded repair procedures to restore damaged composite components. But structural bonded repairs, especially with primary structures, pose several scientific challenges with the current existing repair technologies. In this regard, the area of structural bonded repair of composites is broadly reviewed - starting from damage assessment to automation - to identify current scientific challenges and future opportunities.

  15. Cusp repair in aortic valve reconstruction: does the technique affect stability?

    PubMed

    Aicher, Diana; Langer, Frank; Adam, Oliver; Tscholl, Dietmar; Lausberg, Henning; Schäfers, Hans-Joachim

    2007-12-01

    Cusp prolapse may be an isolated cause of aortic regurgitation or may exist in conjunction with dilatation of the proximal aorta. Prolapse can be corrected by central plication, triangular resection, or pericardial patch implantation. We retrospectively analyzed our results with these techniques. From October 1995 to December 2006, 604 patients (aged 3-86 years) underwent aortic valve repair. Cusp prolapse was found in 427 patients (246 tricuspid, 181 bicuspid). Prolapse was corrected by central plication (n = 275) or triangular resection (n = 80). A pericardial patch was implanted for pre-existing cusp defects or after excision of calcium (n = 72). One cusp was repaired in 198 patients; the remaining patients underwent repair of 2 (n = 189) or 3 cusps (n = 40). In 102 patients more than one technique was used, and the patients were allocated to the group of the assumedly more complex repair (central plication < triangular resection < pericardial patch plasty). Cumulative follow-up was 1238 patient-years (mean 35 +/- 27 months). Hospital mortality was 2.6% (11/427). Actuarial freedom from aortic regurgitation of grade II or more at 5 years was 92% (central plication), 90% (triangular resection), and 90% (pericardial patch plasty). Thirteen patients were reoperated on, with prolapse as the most common reason for failure (n = 7); 6 underwent re-repair. Freedom from reoperation at 5 years was 95% (central plication), 94% (triangular resection), and 94% (pericardial patch plasty). Freedom from valve replacement at 5 years was 97% (central plication), 99% (triangular resection), and 98% (pericardial patch plasty). In aortic valve repair, cusp prolapse can be treated reliably by central plication. In the presence of more complex disease, triangular resection or pericardial patch plasty may be used without compromising midterm durability.

  16. Static Tensile and Transient Dynamic Response of Cracked Aluminum Plate Repaired with Composite Patch - Numerical Study

    NASA Astrophysics Data System (ADS)

    Khalili, S. M. R.; Shariyat, M.; Mokhtari, M.

    2014-06-01

    In this study, the central cracked aluminum plates repaired with two sided composite patches are investigated numerically for their response to static tensile and transient dynamic loadings. Contour integral method is used to define and evaluate the stress intensity factors at the crack tips. The reinforcement for the composite patches is carbon fibers. The effect of adhesive thickness and patch thickness and configuration in tensile loading case and pre-tension, pre-compression and crack length effect on the evolution of the mode I stress intensity factor (SIF) (KI) of the repaired structure under transient dynamic loading case are examined. The results indicated that KI of the central cracked plate is reduced by 1/10 to 1/2 as a result of the bonded composite patch repair in tensile loading case. The crack length and the pre-loads are more effective in repaired structure in transient dynamic loading case in which, the 100 N pre-compression reduces the maximum KI for about 40 %, and the 100 N pre-tension reduces the maximum KI after loading period, by about 196 %.

  17. Repair Options for Airframes

    DTIC Science & Technology

    2001-03-01

    typical applications. This patch configuration can be best obtained with unidirectional tape . Woven material has greater formability and could also...1979. 15. Erdogan F and Arn K, "A Sandwich Plate With a Part-Through and a Debonding Crack," Engineering Fracture Mechanics, Vol. 4, June 1972. 16

  18. Structural Durability of Damaged Metallic Panel Repaired with Composite Patches

    NASA Technical Reports Server (NTRS)

    Minnetyan, Levon; Chamis, Christos C.

    1997-01-01

    Structural durability/damage tolerance characteristics of an aluminum tension specimen possessing a short crack and repaired by applying a fiber composite surface patch is investigated via computational simulation. The composite patch is made of graphite/epoxy plies with various layups. An integrated computer code that accounts for all possible failure modes is utilized for the simulation of combined fiber-composite/aluminum structural degradation under loading. Damage initiation, growth, accumulation, and propagation to structural fracture are included in the simulation. Results show the structural degradation stages due to tensile loading and illustrate the use of computational simulation for the investigation of a composite patch repaired cracked metallic panel.

  19. Tank Remote Repair System Conceptual Design

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kriikku, E.

    2002-12-06

    This document describes two conceptual designs for a Tank Remote Repair System to perform leak site repairs of double shell waste tank walls (Types I, II, III, and IIIA) from the annulus space. The first concept uses a magnetic wall crawler and an epoxy patch system and the second concept uses a magnetic wall crawler and a magnetic patch system. The recommended concept uses the magnetic patch system, since it is simpler to deliver, easier to apply, and has a higher probability of stopping an active leak.

  20. Initial Experience and Early Results of Mitral Valve Repair with Cardiocel Pericardial Patch.

    PubMed

    Tomšič, Anton; Bissessar, Daniella D; van Brakel, Thomas J; Marsan, Nina Ajmone; Klautz, Robert J M; Palmen, Meindert

    2018-06-07

    To assess the performance of a tissue engineering process-treated bovine pericardium patch (CardioCel) in the setting of reconstructive mitral valve surgery. Between 3/2014 and 4/2016, 30 patients (57.2±14.3 years, 27% female) underwent mitral valve leaflet repair with a CardioCel patch. Perioperative mortality was 7% (2 patients, non-graft-related). In 28 remaining patients, pre-discharge echocardiography demonstrated good repaired valve function. At a mean follow-up of 1.7±0.9 years, 3 additional deaths occurred (2 due to infective endocarditis, 1 non-cardiac related). On follow-up echocardiography [follow-up time 1.7±0.8 years, available for 26/28 (93%) hospital survivors], recurrent regurgitation was seen in 2 patients (both infective endocarditis) and 1 underwent reoperation (no infection at the level of patch repair was observed). In the remaining patients, the most recent echocardiogram demonstrated ≤mild regurgitation and stable gradients. The thickness and echodensity of the implanted patch on follow-up echocardiograms were comparable with postoperative echocardiograms. Initial results of the CardioCel patch in mitral valve repair surgery are satisfactory. The resistance to infection and late degeneration will need to be assessed in the future. Copyright © 2018. Published by Elsevier Inc.

  1. The whole truth: comparative analysis of diaphragmatic hernia repair using 4-ply vs 8-ply small intestinal submucosa in a growing animal model.

    PubMed

    Sandoval, John A; Lou, Derek; Engum, Scott A; Fisher, Lisa M; Bouchard, Christine M; Davis, Mary M; Grosfeld, Jay L

    2006-03-01

    Diaphragmatic reconstruction remains a challenging problem. There is limited information concerning the use of small intestinal submucosa (SIS) in congenital diaphragmatic hernia repair. A canine model was used to evaluate the use of a SIS patch in diaphragmatic reconstruction. Eleven beagle puppies (1.6-4.2 kg, 8 weeks old) underwent left subcostal laparotomy, central left hemidiaphragm excision (2 x 7 cm, 50% loss), and reconstruction with a 4-ply group I (n = 5) or 8-ply group II (n = 6) SIS patch. Chest radiographs were taken at time of operation and 3 and 6 months postoperatively. Animals were killed at 6 months. Adhesion formation (both pleural and abdominal), gross visual evaluation of the patch, and histology were compared. In group I (4-ply), 1 animal died at 3 months from patch deterioration accompanied by stomach herniation that resulted in respiratory failure. In the 4 remaining animals, chest radiographs showed no evidence of herniation or eventration. On physical examination, there was no evidence of chest wall deformity. During gross surgical examination, the 4-ply patches showed thinning, multiple defects, and liver herniation in 3 animals. In 1 pup, the patch was thickened, intact, well incorporated at the repair site, and adherent to the liver and spleen. In group II (8-ply), 1 animal died of cardiopulmonary failure in the early postoperative period. In the other 5 animals, chest radiographs showed evidence of eventration in 1. On gross examination the patch adhered to the liver in all 5 surviving animals. In 4, the patches were thickened, viable, but had some shrinkage. One patch pulled away from the native diaphragm laterally; however, no visceral herniation was present. In the 1 animal with eventration, there was no evidence of a patch. Adhesion scores (AS) were graded and determined by the sum of extent (0-4), type (0-4), and tenacity (0-3). Average abdominal AS in group I was 5.6 +/- 0.8 vs 10.2 +/- 0.2 (P = .079) for group II. Average lung AS was 0.6 +/- 0.6 in group I vs 3.8 +/- 1.1 (P = .0476) for group II. Histological examination showed group II patches had greater collagen deposition with central calcification and mild inflammation within the residual graft, whereas group I patches were much thinner and were composed of granulation tissue without evidence of residual graft. These data indicate that 8-ply SIS repair of diaphragmatic defects was superior (80%; 4/5 to 4-ply, 20%; 1/5, success). Organ adherence appears to be necessary for neovascularization of the SIS composite. Eight-ply grafts appear to be more durable and persist for a longer period, which may improve neovascularization. Long-term follow-up to evaluate remodeling characteristics of the patch material is required.

  2. Spatiotemporal modeling of laser tissue soldering using photothermal nanocomposites.

    PubMed

    Mushaben, Madaline; Urie, Russell; Flake, Tanner; Jaffe, Michael; Rege, Kaushal; Heys, Jeffrey

    2018-02-01

    Laser tissue soldering using photothermal solders is a technology that facilitates rapid sealing using heat-induced changes in the tissue and the solder material. The solder material is made of gold nanorods embedded in a protein matrix patch that can be placed over the tissue rupture site and heated with a laser. Although laser tissue soldering is an attractive approach for surgical repair, potential photothermal damage can limit the success of this approach. Development of predictive mathematical models of photothermal effects including cell death, can lead to more efficient approaches in laser-based tissue repair. We describe an experimental and modeling investigation into photothermal solder patches for sealing porcine and mouse cadaver intestine sections using near-infrared laser irradiation. Spatiotemporal changes in temperature were determined at the surface as well as various depths below the patch. A mathematical model, based on the finite element method, predicts the spatiotemporal temperature distribution in the patch and surrounding tissue, as well as concomitant cell death in the tissue is described. For both the porcine and mouse intestine systems, the model predicts temperatures that are quantitatively similar to the experimental measurements with the model predictions of temperature increase often being within a just a few degrees of experimental measurements. This mathematical model can be employed to identify optimal conditions for minimizing healthy cell death while still achieving a strong seal of the ruptured tissue using laser soldering. Lasers Surg. Med. 50:143-152, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  3. The Usefulness of Patch Repair Using the Repermeabilized Umbilical Vein of the Round Ligament for Hepatobiliary Malignancies.

    PubMed

    Takahashi, Michiro; Saiura, Akio; Takahashi, Yu

    2017-11-01

    Patients with tumors invading major veins may require combined resection and reconstruction. However, venous reconstruction often demands complex hepatobiliary and vascular surgical procedures. In this study, we report a simple patch repair technique for venous reconstruction using the repermeabilized umbilical vein of the round ligament. We reviewed the outcomes of eleven patients who underwent venous wedge resection and patch repair using the repermeabilized umbilical vein of the round ligament at our institution. Procurement of the round ligament and method of making a patch is simple. The duration of anastomosis was approximately 15 min. Eight patients (73%) underwent hepatic resection followed by hepatic vein reconstruction; two (18%) pancreaticoduodenectomy followed by inferior vena cava (IVC) reconstruction; one (9%) hepatic resection followed by IVC reconstruction. Although one reconstructed vein became narrowed, the other ten veins were patent after surgery. Patch repair using the repermeabilized umbilical vein of the round ligament is a simple and useful technique.

  4. Stability of double-row rotator cuff repair is not adversely affected by scaffold interposition between tendon and bone.

    PubMed

    Beitzel, Knut; Chowaniec, David M; McCarthy, Mary Beth; Cote, Mark P; Russell, Ryan P; Obopilwe, Elifho; Imhoff, Andreas B; Arciero, Robert A; Mazzocca, Augustus D

    2012-05-01

    Rotator cuff reconstructions may be improved by adding growth factors, cells, or other biologic factors into the repair zone. This usually requires a biological carrier (scaffold) to be integrated into the construct and placed in the area of tendon-to-bone healing. This needs to be done without affecting the constructs mechanics. Hypothesis/ The hypothesis was that scaffold placement, as an interposition, has no adverse effects on biomechanical properties of double-row rotator cuff repair. The purpose of this study was to examine the effect of scaffold interposition on the initial strength of rotator cuff repairs. Controlled laboratory study. Twenty-five fresh-frozen shoulders (mean age: 65.5 ± 8.9 years) were randomly assigned to 5 groups. Groups were chosen to represent a broad spectrum of commonly used scaffold types: (1) double-row repair without augmentation, (2) double-row repair with interposition of a fibrin clot (Viscogel), (3) double-row repair with interposition of a collagen scaffold (Mucograft) between tendon and bone, (4) double-row repair with interposition of human dermis patch (ArthroFlex) between tendon and bone, and (5) double-row repair with human dermis patch (ArthroFlex) placed on top of the repair. Cyclic loading to measure displacement was performed to 3000 cycles at 1 Hz with an applied 10- to 100-N load. The ultimate load to failure was determined at a rate of 31 mm/min. There were no significant differences in mean displacement under cyclic loading, slope, or energy absorbed to failure between all groups (P = .128, P = .981, P = .105). Ultimate load to failure of repairs that used the collagen patch as an interposition (573.3 ± 75.6 N) and a dermis patch on top of the reconstruction (575.8 ± 22.6 N) was higher compared with the repair without a scaffold (348.9 ± 98.8 N; P = .018 and P = .025). No significant differences were found for repairs with the fibrin clot as an interposition (426.9 ± 103.6 N) and the decellularized dermis patch as an interposition (469.9 ± 148.6 N; P = .73 and P = .35). Scaffold augmentation did not adversely affect the zero time strength of the tested standard double-row rotator cuff repairs. An increased ultimate load to failure was observed for 2 of the augmentation methods (collagen patch as an interposition and decellularized dermis patch on top of the reconstruction) compared with the nonaugmented repairs. Scaffolds intended for application of growth factors or cellular components in a repair situation did not adversely jeopardize the stability of the operative construct.

  5. Laparoscopic repair of perforated peptic ulcer-technical tip.

    PubMed

    Jayanthi, Naga Venkatesh Gupta

    2013-08-01

    Increasing number of gastrointestinal emergencies are managed laparoscopically. Laparoscopic repair of a perforated peptic ulcer remains contentious. Fashioning an omental patch is a crucial and an essential part of this repair, whether it is performed open or laparoscopically. This article describes a technique to fashion an adequate omental patch over the perforated peptic ulcer.

  6. Occupational Contact Dermatitis in Mechanics and Repairers Referred for Patch Testing: Retrospective Analysis From the North American Contact Dermatitis Group 1998-2014.

    PubMed

    Warshaw, Erin M; Hagen, Solveig L; Sasseville, Denis; Maibach, Howard I; DeKoven, Joel G; Belsito, Donald V; Fowler, Joseph F; Zug, Kathryn A; Taylor, James S; Mathias, C G Toby; Fransway, Anthony F; DeLeo, Vincent A; Marks, James G; Pratt, Melanie D; Zirwas, Matthew J; Storrs, Frances J

    Contact dermatoses are common in mechanic and repair occupations. This study aimed to (1) estimate the prevalence of occupationally related contact dermatitis among mechanics/repairers patch tested from 1998 to 2014 by the North American Contact Dermatitis Group, (2) characterize responsible allergens and irritants, and their sources, and (3) compare results among 3 occupational subgroups (mechanics, electrical/electronic, and other). A cross-sectional analysis of patients patch tested by the North American Contact Dermatitis Group between 1998 and 2014. Of 38,784 patients patch tested, 691 (1.8%) were mechanics/repairers. Male sex (93.5%) and hand involvement (59.5%) were common overall. Occupationally related skin disease was more prevalent among vehicle and mobile equipment mechanics/repairers (52.7%) and other mechanics/repairers (41.4%) than electrical/electronic equipment mechanics/repairers (21.3%). Overall, carba mix, thiuram mix, and methylchloroisothiazolone/methylisothiazolone were the most common occupation-related clinically relevant allergens. Gloves, automotive vehicles, solvents, oils, lubricants, and fuels were the most common sources of responsible allergens. Common occupationally related allergens included rubber accelerators and the preservative methylchloroisothiazolone/methylisothiazolone.

  7. Polymers Advance Heat Management Materials for Vehicles

    NASA Technical Reports Server (NTRS)

    2013-01-01

    For 6 years prior to the retirement of the Space Shuttle Program, the shuttles carried an onboard repair kit with a tool for emergency use: two tubes of NOAX, or "good goo," as some people called it. NOAX flew on all 22 flights following the Columbia accident, and was designed to repair damage that occurred on the exterior of the shuttle. Bill McMahon, a structural materials engineer at Marshall Space Flight Center says NASA needed a solution for the widest range of possible damage to the shuttle s exterior thermal protection system. "NASA looked at several options in early 2004 and decided on a sealant. Ultimately, NOAX performed the best and was selected," he says. To prove NOAX would work effectively required hundreds of samples manufactured at Marshall and Johnson, and a concerted effort from various NASA field centers. Johnson Space Center provided programmatic leadership, testing, tools, and crew training; Glenn Research Center provided materials analysis; Langley Research Center provided test support and led an effort to perform large patch repairs; Ames Research Center provided additional testing; and Marshall provided further testing and the site of NOAX manufacturing. Although the sealant never had to be used in an emergency situation, it was tested by astronauts on samples of reinforced carbon-carbon (RCC) during two shuttle missions. (RCC is the thermal material on areas of the shuttle that experience the most heat, such as the nose cone and wing leading edges.) The material handled well on orbit, and tests showed the NOAX patch held up well on RCC.

  8. Evaluation of epoxy compounds as a material for patching and protecting concrete : final report.

    DOT National Transportation Integrated Search

    1971-01-01

    The final report summarizes the results of a study of the use of epoxy compounds in the shallow surface repair and sealing of concrete bridge decks. The research effort concentrated on the use of epoxy resin systems as bonded overlays and included ev...

  9. Masonry Procedures. Building Maintenance. Module V. Instructor's Guide.

    ERIC Educational Resources Information Center

    Eck, Francis

    This curriculum guide, one of six modules keyed to the building maintenance competency profile developed by industry and education professionals, provides materials for a masonry procedures unit containing eight lessons. Lesson topics are masonry safety practices; set forms; mix concrete; patch and/or repair concrete; pour and finish concrete; mix…

  10. Contact allergy to denture materials in the burning mouth syndrome.

    PubMed

    van Joost, T; van Ulsen, J; van Loon, L A

    1988-02-01

    Several factors may be responsible for stomatitis in general and the burning mouth syndrome in particular. The results of patch testing are reported in 4 patients with burning mouth symptoms thought to be due to sensitization to denture material. 2 patients reacted to substances in Luxene dentures, but the allergens were not identified. In a 3rd patient, sensitization was found to monomeric methyl methacrylate. The other patient gave positive patch tests to epoxy resin (and bisphenol A), probably present in glue used for repair of dental plates. To obtain a complete diagnosis in cases of suspected contact stomatitis due to allergens in dentures, a reliable standard test series is required.

  11. In-Space Repair of Reinforced Carbon-Carbon (RCC) Thermal Protection System Structures

    NASA Technical Reports Server (NTRS)

    Singh, Mrityunjay

    2005-01-01

    Advanced repair and refurbishment technologies are critically needed for the RCC-based thermal protection system of current space transportation system as well as for future Crew Exploration Vehicles (CEV). The damage to these components could be caused by impact during ground handling or due to falling of ice or other objects during launch. In addition, in-orbit damage includes micrometeoroid and orbital debris impact as well as different factors (weather, launch acoustics, shearing, etc.) during launch and re-entry. The GRC developed GRABER (Glenn Refractory Adhesive for Bonding and Exterior Repair) material has shown multiuse capability for repair of small cracks and damage in reinforced carbon-carbon (RCC) material. The concept consists of preparing an adhesive paste of desired ceramic with appropriate adhesives and then applying the paste to the damaged/cracked area of the RCC composites with adhesive delivery system. The adhesive paste cures at 100-120 C and transforms into a high temperature ceramic during simulated entry conditions. A number of plasma torch and ArcJet tests were carried out to evaluate the crack repair capability of GRABER materials for Reinforced Carbon-Carbon (RCC) composites. For the large area repair applications, PLASTER (Patch Laminates and Sealant Technology for Exterior Repair) based systems have been developed. In this presentation, critical in-space repair needs and technical challenges as well as various issues and complexities will be discussed along with the plasma performance and post test characterization of repaired RCC materials.

  12. Integration of stem cell-derived exosomes with in situ hydrogel glue as a promising tissue patch for articular cartilage regeneration.

    PubMed

    Liu, Xiaolin; Yang, Yunlong; Li, Yan; Niu, Xin; Zhao, Bizeng; Wang, Yang; Bao, Chunyan; Xie, Zongping; Lin, Qiuning; Zhu, Linyong

    2017-03-30

    The regeneration of articular cartilage, which scarcely shows innate self-healing ability, is a great challenge in clinical treatment. Stem cell-derived exosomes (SC-Exos), an important type of extracellular nanovesicle, exhibit great potential for cartilage regeneration to replace stem cell-based therapy. Cartilage regeneration often takes a relatively long time and there is currently no effective administration method to durably retain exosomes at cartilage defect sites to effectively exert their reparative effect. Therefore, in this study, we exploited a photoinduced imine crosslinking hydrogel glue, which presents excellent operation ability, biocompatibility and most importantly, cartilage-integration, as an exosome scaffold to prepare an acellular tissue patch (EHG) for cartilage regeneration. It was found that EHG can retain SC-Exos and positively regulate both chondrocytes and hBMSCs in vitro. Furthermore, EHG can integrate with native cartilage matrix and promote cell deposition at cartilage defect sites, finally resulting in the promotion of cartilage defect repair. The EHG tissue patch therefore provides a novel, cell-free scaffold material for wound repair.

  13. Esophageal replacement by hydroxylated bacterial cellulose patch in a rabbit model.

    PubMed

    Zhu, Changlai; Liu, Fang; Qian, Wenbo; Wang, Yingjie; You, Qingsheng; Zhang, Tianyi; Li, Feng

    2015-01-01

    To repair esophageal defects by hydroxylated and kombucha-synthesized bacterial cellulose (HKBC) patch in a rabbit model. Semicircular esophageal defects 1 cm in length of the cervical esophagus were initially created in 18 Japanese big-ear rabbits and then repaired with HKBC patch grafts. The clinical outcomes including survival rate, weight change, food intake, and hematological and radiologic evaluation were observed. After X-ray evaluation, the rabbits were sacrificed sequentially at 1, 3, and 6 months for histopathologic analysis with light microscopy and scanning electron microscopy. Survival rate during the first month was 88.9% (n = 16). Two rabbits died from anastomotic leakage during the entire follow-up. Postoperatively, feeding function and body weight were gradually restored in the surviving animals. No hematological abnormalities were found, and no obvious anastomotic leakage, stenosis, or obstruction was observed under X-ray examination. The histopathologic results showed a progressive regeneration of the esophagus in the graft area, where the neo-esophagus tissue had characteristics similar to native esophageal tissue after 3 months of surgery. HKBC is beneficial for esophageal tissue regeneration and may be a promising material for esophageal reconstruction.

  14. An electrospun polydioxanone patch for the localisation of biological therapies during tendon repair.

    PubMed

    Hakimi, O; Murphy, R; Stachewicz, U; Hislop, S; Carr, A J

    2012-10-23

    Rotator cuff tendon pathology is thought to account for 30-70 % of all shoulder pain. For cases that have failed conservative treatment, surgical re-attachment of the tendon to the bone with a non-absorbable suture is a common option. However, the failure rate of these repairs is high, estimated at up to 75 %. Studies have shown that in late disease stages the tendon itself is extremely degenerate, with reduced cell numbers and poor matrix organisation. Thus, it has been suggested that adding biological factors such as platelet rich plasma (PRP) and mesenchymal stem cells could improve healing. However, the articular capsule of the glenohumeral joint and the subacromial bursa are large spaces, and injecting beneficial factors into these sites does not ensure localisation to the area of tendon damage. Thus, the aim of this study was to develop a biocompatible patch for improving the healing rates of rotator cuff repairs. The patch will create a confinement around the repair area and will be used to guide injections to the vicinity of the surgical repair. Here, we characterised and tested a preliminary prototype of the patch utilising in vitro tools and primary tendon-derived cells, showing exceptional biocompatibility despite rapid degradation, improved cell attachment and that cells could migrate across the patch towards a chemo-attractant. Finally, we showed the feasibility of detecting the patch using ultrasound and injecting liquid into the confinement ex vivo. There is a potential for using this scaffold in the surgical repair of interfaces such as the tendon insertion in the rotator cuff, in conjunction with beneficial factors.

  15. Fabrication and Characterization of Multi-Walled Carbon Nanotube (MWCNT) and Ni-Coated Multi-Walled Carbon Nanotube (Ni-MWCNT) Repair Patches for Carbon Fiber Reinforced Composite Systems

    NASA Technical Reports Server (NTRS)

    Johnson, Brienne; Caraccio, Anne; Tate, LaNetra; Jackson, Dionne

    2011-01-01

    Multi-walled carbon nanotube (MWCNT)/epoxy and nickel-coated multi-walled carbon nanotube (Ni-MWCNT)/epoxy systems were fabricated into carbon fiber composite repair patches via vacuum resin infusion. Two 4 ply patches were manufactured with fiber orientations of [90/ 90/ 4590] and [0/90/ +45/ -45]. Prior to resin infusion, the MWCNT/Epoxy system and NiMWCNT/ epoxy systems were optimized for dispersion quality. Scanning electron microscopy (SEM) and optical microscopy (OM) were used to determine the presence ofcarbon nanotubes and assess dispersion quality. Decomposition temperatures were determined via thermogravametric analysis (TGA). SEM and TGA were also used to evaluate the composite repair patches.

  16. Assessment of Pulmonary Artery Stiffness of Repaired Congenital Heart Disease Patients

    NASA Astrophysics Data System (ADS)

    Lee, Namheon; Banerjee, Rajit; Taylor, Michael; Hor, Kan

    2012-10-01

    Surgical correction or palliation of congenital heart disease (CHD) often requires augmenting the main pulmonary artery (MPA) with non-native material or placing a cylindrical graft. The degree to which this intervention affects PA compliance is largely unknown. In this study, the MPA stiffness characteristics were assessed by its compliance, distensibility, and pressure-strain modulus. Coregistered velocity encoded phase-contrast MRI and cardiac catheterization data were available for a cohort of repaired CHD patients (n=8) and controls (n=3). All patients were repaired with either an RV-PA conduit or a RV outflow tract patch. We measured the MPA area change by MRI and MPA pressure during the cath. The measurements were taken through or just distal to the conduit. The MPA compliance and distensibility for the patients were significantly lower than the controls: compliance (9.8±10.8 vs 28.3±7.7mm^2/mmHg, p<0.05), distensibility (2.2±1.5 vs 6.6±2.1%Area change/mmHg, p=0.05). The patients had a significantly higher pressure-strain modulus (152.3±116.4mmHg, p<0.05) than the controls (35.8±10.6mmHg). The abnormally elevated PA stiffness due to the rigidity of the conduit or patch material may cause a compliance mismatch resulting in high stress levels contributing to the observed progressive PA dilatation. This may be a factor in the progressive RV dilatation seen in this cohort of repaired CHD patients.

  17. Corrosion/Degradation Monitoring Technology for Composite Materials used to Extend Building Service Life

    DTIC Science & Technology

    2014-07-01

    for patching concrete structures that have corroded reinforcing steel , but the Army largely avoids structural composite repair applications because...J. Dunmire (OUSD(AT&L)), Bernie Rodriguez (IMPW-FM), and Valerie D. Hines (DAIM-ODF). The work was performed by the Engineering and Materials...buildings in the Army inventory often have se- verely corroded reinforcing steel that necessitates structural upgrades for conformance to current safety

  18. The Effects of Platelet-Rich Plasma on Bone Marrow Stromal Cell Transplants for Tendon Healing In Vitro

    PubMed Central

    Morizaki, Yutaka; Zhao, Chunfeng; An, Kai-Nan; Amadio, Peter C.

    2010-01-01

    Purpose In this study we investigated the effect of platelet-rich plasma (PRP) and bone-marrow derived stromal cell (BMSC)-seeded interposition in an in vitro canine tendon repair model. Methods Bone marrow, peripheral blood, and tendons were harvested from mixed breed dogs. BMSC were cultured and passaged from adherent cells of bone marrow suspension. PRP was purified from peripheral blood using a commercial kit. 192 flexor digitorum profundus tendons were used for the study. Tendons repaired with a simple suture were used as a control group. In treatment groups, a collagen gel patch was interposed at the tendon repair site prior to suture. There were three treatment groups according to the type of collagen patch; a patch with PRP, a patch with BMSC, and a patch with PRP and BMSC. The repaired tendons were evaluated by biomechanical testing and by histological survey after 2 and 4 weeks in tissue culture. To evaluate viability, cells were labeled with PKH26 and surveyed under confocal microscopy after culture. Results The maximum breaking strength and stiffness of the healing tendons with the BMSC-seeded PRP patch was significantly higher than the healing tendons without a patch or with a cell-seeded patch (p<0.02). Viable BMSC were present at both 2 and 4 weeks. Conclusions PRP enhanced the effect of BMSC-seeded collagen gel interposition in this in vitro model. Based on these results we now plan to investigate this effect in vivo. PMID:20951509

  19. Concomitant abdominoplasty and umbilical hernia repair using the Ventralex hernia patch.

    PubMed

    Neinstein, Ryan M; Matarasso, Alan; Abramson, David L

    2015-04-01

    Patients requesting abdominoplasty often have concomitant umbilical hernias and may request simultaneous treatment. The vascularity of the umbilicus is potentially at risk during these combined procedures. In this study, the authors present a technique for treating umbilical hernias at the time of abdominoplasty surgery using the Ventralex hernia patch. A total of 11 female patients with a mean age of 39.4 years (range, 28 to 51 years) undergoing abdominoplasty with umbilical hernia repair with the Ventralex patch were included. The mean body mass index was 27.6 kg/m (range, 20 to 34 kg/m). No vascular compromise of the umbilicus was seen. The hernia repair did not alter the abdominoplasty results. One patient had transient umbilical swelling postoperatively that resolved within 6 months postoperatively. The authors present a series of umbilical hernia repairs in abdominoplasty patients using a minimal access incision by means of the rectus fascia and the Ventralex patch that is fast and reliable and preserves the blood supply to the umbilicus.

  20. Stress Analysis of Adhesively Bonded Repairs to Fibre Composite Structures,

    DTIC Science & Technology

    1981-03-01

    which is bonded to a thin sheet of fibre composite material. The x and y axes are taken in a plane parallel to the midsurface of the sheet with the z...SHEET vI X1 FIG. 1 AXIS SYSTEM IN PATCH related to the displacements at the midsurface of the patch, which we will denote by uo, vo and w, and the...displacements at the midsurface of the sheet, which we will denote by u, vs and w, by the following expression: T ( =uo - us +f7 ’ f/fg + (VO - v, +f 7 3)f4

  1. Experimental evaluation of ileal patch in delayed primary repair of penetrating colon injuries: An animal study.

    PubMed

    Abbasi, Hamid Reza; Bolandparvaz, Shahram; Yarmohammadi, Hooman; Geramizadeh, Bita; Tanideh, Nader; Paydar, Shahram; Hosseini, Seyed Vahid

    2006-10-01

    Primary repair of traumatic colonic perforation is progressively gaining acceptance as the best method of management. However, when delayed, the risk of infection-related complications may increase. Here, we present a new method of repairing colon perforation in the presence of peritonitis. Acute colon injury was simulated in 22 German shepherd dogs. The dogs were randomly divided into two groups of 11 and after 24 hours they were operated on. The perforations were repaired by subserosal suture technique. In the first group (group A), ileal patch was used. In the other group (group B), the colon was closed by debridement and anastomosis. After 6 weeks, the repairs were assessed on the basis of survival, gross and histological assessments. Nine (82%) dogs in group A and six (56%) in group B survived. Ileal patch utilization significantly decreased the mortality rate (p < 0.05). The cause of death in two group A dogs and five group B dogs was peritonitis and intra-abdominal abscess formation. None of the surviving dogs showed evidence of anastomotic leakage or breakdown. Small bowel patch used in primary repair of colon injury in the presence of peritonitis may decrease the risk of postoperative infection-related complications and the mortality rate.

  2. Certification Tests on Cold Patch Asphalt Repair Materials for Use in Airfield Pavements

    DTIC Science & Technology

    2010-06-01

    in Airfield Pavements Mariely Mejías-Santiago, Franciso del Valle Roldán, and Lucy P. Priddy Geotechnical and Structures Laboratory U.S. Army...28 Figure 19. Pavement structure in the test section...ERDC), Geotechnical and Structures Laboratory (GSL), Vicksburg, MS. The findings and recommendations presented in this report are based upon laboratory

  3. Portable Holographic Interferometry Testing System: Application to crack patching quality control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heslehurst, R.B.; Baird, J.P.; Williamson, H.M.

    Over recent years the repair of metallic structures has been improved through the use of patches fabricated from composite materials and adhesively bonded to the damaged area. This technology is termed crack patching, and has been successfully and extensively used by the RAAF and the USAF. However, application of the technology to civilian registered aircraft has had limited success due to the apparent lack of suitable quality assurance testing methods and the airworthiness regulators concern overpatch adhesion integrity. Holographic interferometry has previously shown the advantages of detecting out-of-plane deformations of the order of the wavelength of light (1{mu}). Evidence willmore » be presented that holography is able to detect changes in load path due to debonds and weakened adhesion in an adhesively bonded patch. A Portable Holographic Interferometry Testing System (PHITS) which overcomes the vibration isolation problem associated with conventional holography techniques has been developed. The application of PHITS to crack patching technology now provides a suitable method to verify the integrity of bonded patches in-situ.« less

  4. Natural orifice transluminal endoscopic surgery for patients with perforated peptic ulcer.

    PubMed

    Bonin, Eduardo A; Moran, Erica; Gostout, Christopher J; McConico, Andrea L; Zielinski, Martin; Bingener, Juliane

    2012-06-01

    Perforation accounts for 70% of deaths attributed to peptic ulcers. Laparoscopic repair is effective but infrequently used. Our aim was to assess how many patients with perforated peptic ulcer could be candidates for a transluminal endoscopic omental patch closure. This retrospective study reviewed patients with perforated peptic ulcer from 2005 to 2010. Demographics, ulcer characteristics, operative procedure, and outcomes were recorded. Candidates for endoscopic transluminal repair were defined as those having undergone omental patch closure of an ulcer of appropriate size and no contraindications to laparoscopy or endoscopy. In the retrospective review, a total of 104 patients were identified; 62% female, mean age = 68 years, mean ASA of 3, and 63% medication-related ulcers. Fifty-nine (63%) had an omental patch (80% open), and 35 (37%) had other procedures. Ten patients had nonoperative management. Thirty-day mortality was 14% and 1 year mortality was 35%. Forty-nine patients (52%) were considered potential candidates for transluminal repair. Sixty-three percent of our patients sustained a medication-related perforation with 1 year mortality of 35%. The majority of patients were treated using open omental patch repair. Transluminal endoscopic repair may provide an additional situation for a minimally invasive approach for a number of these patients.

  5. Fibrin patch-based insulin-like growth factor-1 gene-modified stem cell transplantation repairs ischemic myocardium.

    PubMed

    Li, Jun; Zhu, Kai; Yang, Shan; Wang, Yulin; Guo, Changfa; Yin, Kanhua; Wang, Chunsheng; Lai, Hao

    2015-05-01

    Bone marrow mesenchymal stem cells (BMSCs), tissue-engineered cardiac patch, and therapeutic gene have all been proposed as promising therapy strategies for cardiac repair after myocardial infarction. In our study, BMSCs were modified with insulin-like growth factor-1 (IGF-1) gene, loaded into a fibrin patch, and then transplanted into a porcine model of ischemia/reperfusion (I/R) myocardium injury. The results demonstrated that IGF-1 gene overexpression could promote proliferation of endothelial cells and cardiomyocyte-like differentiation of BMSCs in vitro. Four weeks after transplantation of fibrin patch loaded with gene-modified BMSCs, IGF-1 overexpression could successfully promote angiogenesis, inhibit remodeling, increase grafted cell survival and reduce apoptosis. In conclusion, the integrated strategy, which combined fibrin patch with IGF-1 gene modified BMSCs, could promote the histological cardiac repair for a clinically relevant porcine model of I/R myocardium injury. © 2015 by the Society for Experimental Biology and Medicine.

  6. Reduction of Moisture Effects During the Cure of Epoxy Adhesives Used in Composite Repair

    NASA Technical Reports Server (NTRS)

    Augl, J. M.; Sivy, G. T.

    1985-01-01

    The requirements for repair work on Naval aircraft composite wing skins that can be performed under depot conditions (or still worse, under field conditions) are quite restrictive. Equipment that can be used is rather limited as are the available repair space and time. The procedures must be simple enough so that they can be performed satisfactorily by personnel without special knowledge in composite materials technology. Repairs of small holes should not require more than perhaps a short predrying cycle (with heat guns) and a subsequent patch bonding using a heating blanket, held in place by applying a vacuum. However, it has been observed during simulated experimental repair work that the glue lines frequently show a high content of pores and bubbles which are attributed to evaporation of moisture during the curing cycle. (Of course, other volatile materials such as residual solvent would act similarly). The purpose of this paper is to give some detailed analysis of the problem of moisture transport as a function of repair conditions, and to discuss some preliminary work to reduce the effect of moisture by removing moisture chemically with carbodiimides before it reaches a critical level for bubble formations.

  7. Catheter enterostomy and patch repair of the abdominal wall for gastroschisis with intestinal atresia: report of a case.

    PubMed

    Ohno, Koichi; Nakamura, Tetsuro; Azuma, Takashi; Yoshida, Tatsuyuki; Yamada, Hiroto; Hayashi, Hiroaki; Masahata, Kazunori

    2009-01-01

    A male infant, weighing 2177 g, was born with the entire intestine protruding through a defect on the right side of the navel. Intestinal atresia, approximately 70 cm from the Treitz ligament, was also confirmed. Primary anastomosis and abdominal wall repair were impossible because of the intestinal dilation and thick peel, as well as the small abdominal cavity. Thus, we initially performed catheter enterostomy with a 14-F balloon catheter and patch repair of the abdominal wall, to enable the baby to be fed. Secondary anastomosis and abdominal wall repair was safely performed when the baby was 106 days old. The combination of catheter enterostomy and patch repair of the abdominal wall does not require dissection of the intestine and it can be safely performed in low-birth-weight babies. It also enables feeding and weight gain, and the overlying skin prevents contamination of the artificial sheet. We recommend this combination for neonates with both gastroschisis and intestinal atresia.

  8. Use of buccal mucosa patch graft for recurrent large urethrocutaneous fistula after hypospadias repair.

    PubMed

    Kiss, András; Pirót, László; Karsza, Levente; Merksz, Miklós

    2004-01-01

    To assess the effectiveness of buccal mucosa patch graft in the treatment of recurrent large urethrocutaneous fistula after hypospadias repair. A free graft of buccal mucosa was used for closure in 7 boys (mean age 4.8 years) with large (>4 mm) urethocutaneous fistula. Four fistulas were in the midshaft, 2 of them penoscrotal and 1 coronal type. All patients had undergone at least two previous unsuccessful fistula repairs, and 3 of them had undergone three attempts for closure. Fistula repairs were similar in all cases. The repair was successful in 6 out of 7 cases, and in these cases the urinary stream was good after the removal of the catheter. The unsuccessful case was the coronal one. Based on our experience it seems that in cases with recurrent large fistula after hypospadias reconstruction, the use of buccal mucosa patch graft for closure is a good treatment choice. Copyright 2004 S. Karger AG, Basel

  9. Experimental study of ASCs combined with POC-PLA patch for the reconstruction of full-thickness chest wall defects.

    PubMed

    Zhang, Yuanzheng; Fang, Shuo; Dai, Jiezhi; Zhu, Lei; Fan, Hao; Tang, Weiya; Fan, Yongjie; Dai, Haiying; Zhang, Peipei; Wang, Ying; Xing, Xin; Yang, Chao

    2017-01-01

    To explore the repairing effect of combination of adipose stem cells (ASCs) and composite scaffolds on CWR, the electrospun Poly 1, 8-octanediol-co-citric acid (POC)-poly-L-lactide acid (PLA) composite scaffolds were prepared, followed by in vitro and in vivo biocompatibility evaluation of the scaffolds. Afterwards, ASCs were seeded on POC-PLA to construct the POC-PLA-ASCs scaffolds, and the POC-PLA, POC-PLA-ASCs, and traditional materials expanded polytetrafluoroethylene (ePTFE) were adopt for CWR in New Zealand white (NZW) rabbit models. As results, the POC-PLA-ASCs patches possessed good biocompatibility as the high proliferation ability of cells surrounding the patches. Rabbits in POC-PLA-ASCs groups showed better pulmonary function, less pleural adhesion, higher degradation rate and more neovascularization when compared with that in other two groups. The results of western blot indicated that POC-PLA-ASCs patches accelerated the expression of VEGF and Collagen I in rabbit models. From the above, our present study demonstrated that POC-PLA material was applied for CWR successfully, and ASCs seeded on the sheets could improve the pleural adhesions and promote the reparation of chest wall defects.

  10. Damage Assessment of Composite Structures Using Digital Image Correlation

    NASA Astrophysics Data System (ADS)

    Caminero, M. A.; Lopez-Pedrosa, M.; Pinna, C.; Soutis, C.

    2014-02-01

    The steady increase of Carbon-Fiber Reinforced Polymer (CFRP) Structures in modern aircraft will reach a new dimension with the entry into service of the Boeing 787 and Airbus 350. Replacement of damaged parts will not be a preferable solution due to the high level of integration and the large size of the components involved. Consequently the need to develop repair techniques and processes for composite components is readily apparent. Bonded patch repair technologies provide an alternative to mechanically fastened repairs with significantly higher performance, especially for relatively thin skins. Carefully designed adhesively bonded patches can lead to cost effective and highly efficient repairs in comparison with conventional riveted patch repairs that cut fibers and introduce highly strained regions. In this work, the assessment of the damage process taking place in notched (open-hole) specimens under uniaxial tensile loading was studied. Two-dimensional (2D) and three-dimensional (3D) Digital Image Correlation (DIC) techniques were employed to obtain full-field surface strain measurements in carbon-fiber/epoxy T700/M21 composite plates with different stacking sequences in the presence of an open circular hole. Penetrant enhanced X-ray radiographs were taken to identify damage location and extent after loading around the hole. DIC strain fields were compared to finite element predictions. In addition, DIC techniques were used to characterise damage and performance of adhesively bonded patch repairs in composite panels under tensile loading. This part of work relates to strength/stiffness restoration of damaged composite aircraft that becomes more important as composites are used more extensively in the construction of modern jet airliners. The behaviour of bonded patches under loading was monitored using DIC full-field strain measurements. Location and extent of damage identified by X-ray radiography correlates well with DIC strain results giving confidence to the technique for structural health monitoring of bonded patches.

  11. Molecular biology of Streptococcus pneumoniae: an everlasting challenge.

    PubMed

    Sicard, M; Gasc, A M; Giammarinaro, P; Lefrançois, J; Pasta, F; Samrakandi, M

    2000-01-01

    Streptococcus pneumoniae is a model for elucidating: 1) recombination steps of DNA, from its discovery to polarity of integration; 2) long-patch mismatch repair, short-patch repair triggered by A/G and exclusion of deletions; 3) resistance to beta-lactam antibiotics; and 4) factors of virulence. Several of these topics remain a challenge for future investigations.

  12. Dimer excision in Escherichia coli in the presence of caffeine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rothman, R.H.

    1980-07-01

    The observation that polA1 and recL152 mutations result in both slow pyrimidine dimer excision and large repair patch size leads to the hypothesis that patch size is directly related to the rate of excision. In this study caffeine, a known inhibitor of excision repair, was used to examine the extent of correlation between excision rate and patch size by measuring patch size in the presence of several concentrations of caffeine. Both the rate of excision and the resistance to ultraviolet radiation were reduced with increasing concentrations of caffeine after irradiation. Caffeine also inhibited the rate at which incisions were mademore » and prolonged the time required to rejoin the discontinuities. Patch size, however, was unaffected by caffeine treatment.« less

  13. Synthetic and degradable patches: an emerging solution for rotator cuff repair

    PubMed Central

    Hakimi, Osnat; Mouthuy, Pierre-Alexis; Carr, Andrew

    2013-01-01

    The use of rotator cuff augmentation has increased dramatically over the last 10 years in response to the high rate of failure observed after non-augmented surgery. However, although augmentations have been shown to reduce shoulder pain, there is no consensus or clear guideline as to what is the safest or most efficacious material. Current augmentations, either available commercially or in development, can be classified into three categories: non-degradable structures, extra cellular matrix (ECM)-based patches and degradable synthetic scaffolds. Non-degradable structures have excellent mechanical properties, but can cause problems of infection and loss of integrity in the long-term. ECM-based patches usually demonstrate excellent biological properties in vitro, but studies have highlighted complications in vivo due to poor mechanical support and to infection or inflammation. Degradable synthetic scaffolds represent the new generation of implants. It is proposed that a combination of good mechanical properties, active promotion of biological healing, low infection risk and bio-absorption are the ideal characteristics of an augmentation material. Among the materials with these features, those processed by electrospinning have shown great promis. However, their clinical effectiveness has yet to be proven and well conducted clinical trials are urgently required. PMID:23837794

  14. Generalized peritonitis requiring re-operation after leakage of omental patch repair of perforated peptic ulcer.

    PubMed

    Maghsoudi, Hemmat; Ghaffari, Alireza

    2011-01-01

    Peptic ulcer perforations are a common emergency, but available literature is silent on the exact definition, incidence, management, and complications of peritonitis due to omental patch leakage. Retrospective data were collected on 422 patients who underwent omental patch repair of perforated peptic ulcer between March 20, 1999 and March 20, 2006. The definitive diagnosis of perforated peptic ulcer and omental patch leakage was obtained at surgery. Seventeen (4%) patients experienced generalized peritonitis due to omental patch leakage. Mean age was 60.6 years. Mortality rate was 29.4%, and the mean hospital stay was 23.6 days. Delay in surgical approach, shock on admission, and age were all significantly associated with increased mortality. Peritonitis due to omental patch leakage can result in significant morbidity and mortality. The most common causes of omental patch leakage and operative procedures were unknown and reinsertion of omentum, respectively. Factors such as shock on admission or delayed surgery, have significantly contributed to fatal outcomes and need careful attention.

  15. The effects of platelet lysate patches on the activity of tendon-derived cells.

    PubMed

    Costa-Almeida, Raquel; Franco, Albina R; Pesqueira, Tamagno; Oliveira, Mariana B; Babo, Pedro S; Leonor, Isabel B; Mano, João F; Reis, Rui L; Gomes, Manuela E

    2018-03-01

    Platelet-derived biomaterials are widely explored as cost-effective sources of therapeutic factors, holding a strong potential for endogenous regenerative medicine. Particularly for tendon repair, treatment approaches that shift the injury environment are explored to accelerate tendon regeneration. Herein, genipin-crosslinked platelet lysate (PL) patches are proposed for the delivery of human-derived therapeutic factors in patch augmentation strategies aiming at tendon repair. Developed PL patches exhibited a controlled release profile of PL proteins, including bFGF and PDGF-BB. Additionally, PL patches exhibited an antibacterial effect by preventing the adhesion, proliferation and biofilm formation by S. aureus, a common pathogen in orthopaedic surgical site infections. Furthermore, these patches supported the activity of human tendon-derived cells (hTDCs). Cells were able to proliferate over time and an up-regulation of tenogenic genes (SCX, COL1A1 and TNC) was observed, suggesting that PL patches may modify the behavior of hTDCs. Accordingly, hTDCs deposited tendon-related extracellular matrix proteins, namely collagen type I and tenascin C. In summary, PL patches can act as a reservoir of biomolecules derived from PL and support the activity of native tendon cells, being proposed as bioinstructive patches for tendon regeneration. Platelet-derived biomaterials hold great interest for the delivery of therapeutic factors for applications in endogenous regenerative medicine. In the particular case of tendon repair, patch augmentation strategies aiming at shifting the injury environment are explored to improve tendon regeneration. In this study, PL patches were developed with remarkable features, including the controlled release of growth factors and antibacterial efficacy. Remarkably, PL patches supported the activity of native tendon cells by up-regulating tenogenic genes and enabling the deposition of ECM proteins. This patch holds great potential towards simultaneously reducing post-implantation surgical site infections and promoting tendon regeneration for prospective in vivo applications. Copyright © 2018 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  16. Methods of Making and Using Shape Memory Polymer Composite Patches

    NASA Technical Reports Server (NTRS)

    Hood, Patrick J.

    2011-01-01

    A method of repairing a composite component having a damaged area including: laying a composite patch over the damaged area: activating the shape memory polymer resin to easily and quickly mold said patch to said damaged area; deactivating said shape memory polymer so that said composite patch retains the molded shape; and bonding said composite patch to said damaged part.

  17. Endovascular treatment of false-aneurysm ten years after dacron patch aortoplasty for coarctation of the aortic isthmus. Report of a case.

    PubMed

    Illuminati, Giulio; Pacilè, Maria Antonietta; Palumbo, Piergaspare; Salvatori, Filippo Maria; Vietri, Francesco

    2013-01-01

    False aneurysm degeneration is a known complication of patch aortoplasty for coarctation of the aortic isthmus. Open surgical treatment consists of prosthetic graft repair of the involved aorta, often requires circulatory arrest to achieve a safe proximal aortic control and perform proximal anastomosis, and finally is associated with substantial perioperative morbidity. Endografting of the diseased aorta is a valuable alternative to open repair, when feasible, with good short and long term results. We now report one more case of false aneurysm ten years after Dacron patch aortoplasty for isthmic coarctation in a 26-year-old woman, successfully treated by endovascular repair via the left common iliac artery, and a complete exclusion of the aneurysm at two year follow-up.

  18. Computer-aided patch planning for treatment of complex coarctation of the aorta

    NASA Astrophysics Data System (ADS)

    Rietdorf, Urte; Riesenkampff, Eugénie; Kuehne, Titus; Huebler, Michael; Meinzer, Hans-Peter; Wolf, Ivo

    2009-02-01

    Between five and eight percent of all children born with congenitally malformed hearts suffer from coarctations of the aorta. Some severe coarctations can only be treated by surgical repair. Untreated, this defect can cause serious damage to organ development or even lead to death. Patch repair requires open surgery. It can affect patients of any age: newborns with severe coarctation and/or hypoplastic aortic arch as well as older patients with late diagnosis of coarctation of the aorta. Another patient group are patients of varying age with re-coarctation of the aorta or hypoplastic aortic arch after surgical and/or interventional repair. If anatomy is complex and interventional treatment by catheterization, balloon angioplasty or stent placement is not possible, surgery is indicated. The choice of type of surgery depends not only on the given anatomy but also on the experience the surgical team has with each method. One surgical approach is patch repair. A patch of a suitable shape and size is sewed into the aorta to expand the aortic lumen at the site of coarctation. At present, the shape and size of the patch are estimated intra-operatively by the surgeon. We have developed a software application that allows planning of the patch pre-operatively on the basis of magnetic resonance angiographic data. The application determines the diameter of the coarctation and/or hypoplastic segment and constructs a patch proposal by calculating the difference to the normal vessel diameter pre-operatively. Evaluation of MR angiographic datasets from 12 test patients with different kinds of aortic arch stenosis shows a divergence of only (1.5+/-1.2) mm in coarctation diameters between manual segmentations and our approach, with comparable time expenditure. Following this proposal the patch can be prepared and adapted to the patient's anatomy pre-operatively. Ideally, this leads to shorter operation times and a better long-term outcome with a reduced rate of residual stenosis and re-stenosis and aneurysm formation.

  19. New In-Field Composite Repair Techniques for Transmission or Distribution Pipelines

    DOT National Transportation Integrated Search

    2009-05-18

    In-field repair of a damaged pipeline must be performed safely, efficiently, rapidly and reliably. Reinforcement of damaged pipelines is typically accomplished by welding a repair patch and then recoating the repaired area. The welded full-encircleme...

  20. Two layer structure for reinforcing pothole repair

    NASA Astrophysics Data System (ADS)

    Yuan, Wei; Yuan, Kuo-Yao; Zou, Linhua; Yang, Jenn-Ming; Ju, Jiann-Wen; Kao, Wei; Carlson, Larry

    2013-04-01

    We have applied dicyclopentadiene (DCPD) resin for reinforcing pothole patch materials due to its unique properties - low cost, low viscosity at beginning and ultra-toughness after curing, chemical compatibility with tar, tunable curing profile through catalyst design. In this paper, we have designed a two layer structure - well compacted base layer and DCPD reinforced 1-1.5" top layer - for pothole repair. By choosing two graded asphalt mixes, a porous top layer and fully compacted base layer was prepared after compaction and ready for DCPD resin infiltration. The DCPD curing and infiltration profile within this porous top layer was measured with thermocouples. The rutting resistance was tested with home-made wheel rutter. The cage effect due to the p-DCPD wrapping was characterized with wheel penetration test. The results showed that this two layer structure pothole repair has greatly improved properties and can be used for pothole repair to increase the service life.

  1. Surgical repair of supravalvular aortic stenosis in children with williams syndrome: a 30-year experience.

    PubMed

    Fricke, Tyson A; d'Udekem, Yves; Brizard, Christian P; Wheaton, Gavin; Weintraub, Robert G; Konstantinov, Igor E

    2015-04-01

    Williams syndrome is an uncommon genetic disorder associated with supravalvular aortic stenosis (SVAS) in childhood. We reviewed outcomes of children with Williams syndrome who underwent repair of SVAS during a 30-year period at a single institution. Between 1982 and 2012, 28 patients with Williams syndrome were operated on for SVAS. Mean age at operation was 5.2 years (range, 3 months to 13 years), and mean weight at operation was 18.6 kg (range, 4.1 to 72.4 kg). Associated cardiac lesions in 11 patients (39.3%) were repaired at the time of the SVAS repair. The most common associated cardiac lesion was main pulmonary artery stenosis (8 of 28 [28%]). A 3-patch repair was performed in 10 patients, a Doty repair in 17, and a McGoon repair in 1 (3.6%). There were no early deaths. Follow-up was 96% complete (27 of 28). Overall mean follow-up was 11.2 years (range, 1 month to 27.3 years). Mean follow-up was 5 years (range, 1 month to 14.3 years) for the 3-patch repair patients and 14.7 years (range, 6 weeks to 27 years) for the Doty repair patients. Of the 17 Doty patients, there were 4 (24%) late deaths, occurring at 6 weeks, 3.5 years, 4 years, and 16 years after the initial operation. There were no late deaths in the 3-patch repair patients. Overall survival was 86% at 5, 10, and 15 years after repair. Survival was 82% at 5, 10 and 15 years for the Doty repair patients. Overall, 6 of 27 patients (22%) patients required late reoperation at a mean of 11.2 years (range, 3.6 to 23 years). No 3-patch repair patients required reoperation. Overall freedom from reoperation was 91% at 5 years and 73% at 10 and 15 years. Freedom from reoperation for the Doty repair patients was 93% at 5 years and 71% at 10 and 15 years. Surgical repair of SVAS in children Williams syndrome has excellent early results. However, significant late mortality and morbidity warrants close follow-up. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  2. Dye-enhanced protein solders and patches in laser-assisted tissue welding.

    PubMed

    Small, W; Heredia, N J; Maitland, D J; Da Silva, L B; Matthews, D L

    1997-01-01

    This study examines the use of dye-enhanced protein bonding agents in 805 nm diode laser-assisted tissue welding. A comparison of an albumin liquid solder and collagen solid-matrix patches used to repair arteriotomies in an in vitro porcine model is presented. Extrinsic bonding media in the form of solders and patches have been used to enhance the practice of laser tissue welding. Preferential absorption of the laser wavelength has been achieved by the incorporation of chromophores. Both the solder and the patch included indocyanine green dye (ICG) to absorb the 805 nm continuous-wave diode laser light used to perform the welds. Solder-mediated welds were divided into two groups (high power/short exposure and low power/long exposure), and the patches were divided into three thickness groups ranging from 0.1 to 1.3 mm. The power used to activate the patches was constant, but the exposure time was increased with patch thickness. Burst pressure results indicated that solder-mediated and patched welds yielded similar average burst strengths in most cases, but the patches provided a higher success rate (i.e., more often exceeded 150 mmHg) and were more consistent (i.e., smaller standard deviation) than the solder. The strongest welds were obtained using 1.0-1.3 mm thick patches, while the high power/short exposure solder group was the weakest. Though the solder and patches yielded similar acute weld strengths, the solid-matrix patches facilitated the welding process and provided consistently strong welds. The material properties of the extrinsic agents influenced their performance.

  3. Management of carotid Dacron patch infection: a case report using median sternotomy for proximal common carotid artery control and in situ polytetrafluoroethylene grafting.

    PubMed

    Illuminati, Giulio; Calio', Francesco G; D'Urso, Antonio; Ceccanei, Gianluca; Pacilè, Maria Antonietta

    2009-01-01

    We report on a 58-year-old male who presented with an enlarging cervical hematoma 3 months following carotid endarterectomy with Dacron patch repair, due to septic disruption of the Dacron patch secondary to presumed infection. The essential features of this case are the control of the proximal common carotid artery gained through a median sternotomy, because the patient was markedly obese with minimal thyromental distance, and the treatment consisting of in situ polytetrafluoroethylene bypass grafting, due to the absence of a suitable autogenous saphenous vein. Median sternotomy is rarely required in case of reintervention for septic false aneurysms and hematomas following carotid endarterectomy but should be considered whenever difficult control of the common carotid artery, when entering the previous cervicotomy, is anticipated. In situ polytetrafluoroethylene grafting can be considered if autogenous vein material is lacking.

  4. The benefit of synthetic versus biological patch augmentation in the repair of posterosuperior massive rotator cuff tears: a 3-year follow-up study.

    PubMed

    Ciampi, Pietro; Scotti, Celeste; Nonis, Alessandro; Vitali, Matteo; Di Serio, Clelia; Peretti, Giuseppe M; Fraschini, Gianfranco

    2014-05-01

    Rotator cuff repair typically results in a satisfactory, although variable, clinical outcome. However, anatomic failure of the repaired tendon often occurs. Patch augmentation can improve the results of open rotator cuff repair by supporting the healing process, protecting the suture, and reducing friction in the subacromial space. Cohort study; Level of evidence, 3. A total of 152 patients with a posterosuperior massive rotator cuff tear were treated by open repair only (control group; n = 51; mean age, 67.06 ± 4.42 years), open repair together with collagen patch augmentation (collagen group; n = 49; mean age, 66.53 ± 5.17 years), or open repair together with polypropylene patch augmentation (polypropylene group; n = 52; mean age, 66.17 ± 5.44 years) and were retrospectively studied. Patients were evaluated preoperatively and after 36 months with a visual analog scale (VAS) and the University of California, Los Angeles (UCLA) shoulder rating scale and by measuring elevation of the scapular plane and strength with a dynamometer. The VAS and UCLA scores were also obtained 2 months postoperatively. Tendon integrity was assessed after 1 year by ultrasound. Patients were homogeneous as per the preoperative assessment. After 2 months, results (mean ± standard deviation) for the control, collagen, and polypropylene groups, respectively, were as follows: VAS scores were 6.96 ± 1.11, 6.46 ± 1.02, and 4.92 ± 0.90, while UCLA scores were 11.29 ± 1.46, 11.40 ± 1.51, and 19.15 ± 1.99. After 36 months, the mean scores for the respective groups were 3.66 ± 1.05, 4.06 ± 1.02, and 3.28 ± 1.10 for the VAS and 14.88 ± 1.98, 14.69 ± 1.99, and 24.61 ± 3.22 for the UCLA scale. In addition, after 36 months, elevation on the scapular plane was 140.68° ± 9.84°, 140.61° ± 12.48°, and 174.71° ± 8.18°, and abduction strength was 8.73 ± 0.54 kg, 9.03 ± 0.60 kg, and 13.79 ± 0.64 kg for the control, collagen, and polypropylene groups, respectively. The retear rate after 12 months was 41% (21/51) for the control group, 51% (25/49) for the collagen group, and 17% (9/52) for the polypropylene group. In particular, the reduced 12-month retear rate and the increased UCLA scores, abduction strength, and elevation at 3-year follow-up were statistically significant for patients treated with a polypropylene patch compared with those treated with repair only or with a collagen patch. Polypropylene patch augmentation of rotator cuff repair was demonstrated to significantly improve the 36-month outcome in terms of function, strength, and retear rate.

  5. Generalized Peritonitis Requiring Re-operation After Leakage of Omental Patch Repair of Perforated Peptic Ulcer

    PubMed Central

    Maghsoudi, Hemmat; Ghaffari, Alireza

    2011-01-01

    Background/Aim: Peptic ulcer perforations are a common emergency, but available literature is silent on the exact definition, incidence, management, and complications of peritonitis due to omental patch leakage. Patients and Methods: Retrospective data were collected on 422 patients who underwent omental patch repair of perforated peptic ulcer between March 20, 1999 and March 20, 2006. The definitive diagnosis of perforated peptic ulcer and omental patch leakage was obtained at surgery. Results: Seventeen (4%) patients experienced generalized peritonitis due to omental patch leakage. Mean age was 60.6 years. Mortality rate was 29.4%, and the mean hospital stay was 23.6 days. Delay in surgical approach, shock on admission, and age were all significantly associated with increased mortality. Conclusions: Peritonitis due to omental patch leakage can result in significant morbidity and mortality. The most common causes of omental patch leakage and operative procedures were unknown and reinsertion of omentum, respectively. Factors such as shock on admission or delayed surgery, have significantly contributed to fatal outcomes and need careful attention. PMID:21372350

  6. Evaluation of precast patches on U.S. 60 near the New Kent and James City County line.

    DOT National Transportation Integrated Search

    2006-01-01

    This project evaluated the use of precast concrete patches for repairing jointed concrete pavement. Six patches were placed: three had dowels cast into them during fabrication, and three had dowels inserted in place (dowel bar retrofit). Fabrication ...

  7. Treatment of massive and recurrent rotator cuff tears augmented with a poly-l-lactide graft, a preliminary study.

    PubMed

    Lenart, Brett A; Martens, Kelly A; Kearns, Kenneth A; Gillespie, Robert J; Zoga, Adam C; Williams, Gerald R

    2015-06-01

    The incidence of failed rotator cuff repairs remains high, especially in the setting of massive tears or revision repairs. The purpose of this study was to evaluate patient outcomes and repair integrity after augmentation with the repair patch, a poly-l-lactide synthetic polymer. Sixteen consecutive patients with massive or recurrent rotator cuff tears underwent open repair with synthetic poly-l-lactide patch augmentation. Two patients required the patch to bridge defects, and 1 patient retore after a motor vehicle accident and had revision surgery at another institution. The 13 remaining patients were retrospectively evaluated from 1.2 to 1.7 years (average, 1.5 years) after surgery by PENN, American Shoulder and Elbow Surgeons, and Single Assessment Numeric Evaluation scores. Magnetic resonance imaging was used to examine the integrity of the repair at a minimum of 1 year of follow-up. The mean age was 57.3 years (42-68 years). Five patients (38%) had an intact rotator cuff at the time of follow-up. The remaining patients (62%) had full-thickness tears. PENN scores significantly improved from a preoperative score of 50.9 to 77.6 (P < .005). American Shoulder and Elbow Surgeons scores significantly improved from 32.8 to 74.2 (P = .0001). Single Assessment Numeric Evaluation scores at latest follow-up were 76.2. Poly-l-lactide repair patch augmentation of massive and recurrent large to massive rotator cuff tears demonstrates significant improvement in shoulder outcome measures for this difficult population, despite a retear rate of 62%. Further investigation with larger, prospective long-term studies is needed to determine whether this technique provides a true benefit compared with traditional, nonaugmented repair. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  8. Influence of very short patch mismatch repair on SOS inducing lesions after aminoglycoside treatment in Escherichia coli.

    PubMed

    Baharoglu, Zeynep; Mazel, Didier

    2014-01-01

    Low concentrations of aminoglycosides induce the SOS response in Vibrio cholerae but not in Escherichia coli. In order to determine whether a specific factor present in E. coli prevents this induction, we developed a genetic screen where only SOS inducing mutants are viable. We identified the vsr gene coding for the Vsr protein of the very short patch mismatch repair (VSPR) pathway. The effect of mismatch repair (MMR) mutants was also studied. We propose that lesions formed upon aminoglycoside treatment are preferentially repaired by VSPR without SOS induction in E. coli and by MMR when VSPR is impaired. Copyright © 2014 Institut Pasteur. Published by Elsevier Masson SAS. All rights reserved.

  9. PEMFs: new post-surgical management in dentristry

    NASA Astrophysics Data System (ADS)

    Tonetti, Luca

    2014-01-01

    Aim of study: the possible effects on dental postsurgical management using small and not invasive devices: RecoveryRx or ActiPatch producted by Bioelectronics company (USA) Materials and methods: review of literature using searching engines Keywords: PEMFs, postsurgical treatment, pain, wound healing, RecoveryRx, ActiPatch Results: Pulsed Electro Magnetic Fields have been used extensively for decades for many conditions and medical disciplines. Imperceptible cell dysfunction that is not corrected early can lead to disease. Fine-tuning can be done daily in only minutes, using pulsed electromagnetic fields (PEMFs). In addition, when there is a known imbalance (when symptoms are present) or there is a known disease or condition, PEMF treatments, used either alone or along with other therapies, can often help cells rebalance dysfunction faster. It is seen in literature that RecoveryRX and ActiPatch improve the cell metabolism, rebalance the membrane potential difference, improve the circulation and the oxigenation of the tissues, acceleration of osteogenesis, acceleration repair of soft tissues, reduce pain. Conclusion: the RecoveryRX and ActiPatch devices could improve the postsurgical healing reducing the patient discomfort.

  10. Effect of platelet-rich plasma and porcine dermal collagen graft augmentation for rotator cuff healing in a rabbit model.

    PubMed

    Chung, Seok Won; Song, Byung Wook; Kim, Yeun Ho; Park, Kyoung Un; Oh, Joo Han

    2013-12-01

    The rate of healing failure after surgical repair of chronic rotator cuff tears is considerably high. To verify the effect of platelet-rich plasma (PRP) with and without porcine dermal collagen graft augmentation on tendon-to-bone healing, using the rabbit supraspinatus tendon. Controlled laboratory study. A total of 80 rabbits were randomly allocated into 4 groups (20 rabbits per group: 12 for histological and 8 for mechanical testing): repair (R), repair + patch augmentation (RPa), repair + PRP (RPr), and repair + patch + PRP (RPaPr). The right shoulder was used for experimental interventions, and the left served as a control. Six weeks after the detachment of the supraspinatus, the torn tendon was repaired in a transosseous manner, simulating double-row repair in all groups. Platelet-rich plasma was prepared and applied onto the repair site in the RPr and RPaPr groups, and the patch was used to augment the repair in the RPa and RPaPr groups. The mechanical tensile strength test was performed at 8 weeks after repair and the histological evaluation at 4 and 8 weeks. At 4 weeks, the collagen fibers were poorly organized, and fiber continuity was not established in all groups. However, vascularity and cellularity were higher with granulation tissue formation in the PRP-treated groups (RPr and RPaPr) than the nontreated groups (R and RPa). At 8 weeks, tendon-to-bone integration was much improved with more collagen fibers, and longitudinally oriented collagen fibers were visible in all groups. The PRP-treated groups showed better collagen fiber continuity and orientation than the nontreated groups; however, no distinctive difference was found between the patch-augmented groups (RPa and RPaPr) and nonaugmented groups (R and RPr). The mean load-to-failure results were 61.57 ± 29.99 N, 76.84 ± 16.08 N, 105.35 ± 33.82 N, and 117.93 ± 12.60 N for the R, RPa, RPr, and RPaPr groups, respectively, and they were significantly different between the R and RPr (P = .018), R and RPaPr (P = .002), and RPa and RPaPr (P = .029) groups. This animal study showed the enhancement of tendon-to-bone healing after local administration of autologous PRP assessed by histological and biomechanical testing in a rabbit model of chronic rotator cuff tears. However, there was little additive effect of the patch graft. The use of PRP might be a biological supplement to increase the rotator cuff healing rate, which still remains low even after successful cuff repair, but this result should be interpreted with caution regarding clinical applications.

  11. Partial-depth precast concrete patching.

    DOT National Transportation Integrated Search

    1974-01-01

    Experiments were performed with partial-depth precast concrete patching to determine the feasibility of the method. In the experiments prefabricated slabs of various sizes, stockpiled near the pavement repair site were installed in machine cut holes ...

  12. DNA repair in mammalian mitochondria: Much more than we thought?

    PubMed

    Liu, Pingfang; Demple, Bruce

    2010-06-01

    For many years, the repair of most damage in mitochondrial DNA (mtDNA) was thought limited to short-patch base excision repair (SP-BER), which replaces a single nucleotide by the sequential action of DNA glycosylases, an apurinic/apyrimidinic (AP) endonuclease, the mitochondrial DNA polymerase gamma, an abasic lyase activity, and mitochondrial DNA ligase. However, the likely array of lesions inflicted on mtDNA by oxygen radicals and the possibility of replication errors and disruptions indicated that such a restricted repair repertoire would be inadequate. Recent studies have considerably expanded our knowledge of mtDNA repair to include long-patch base excision repair (LP-BER), mismatch repair, and homologous recombination and nonhomologous end-joining. In addition, elimination of mutagenic 8-oxodeoxyguanosine triphosphate (8-oxodGTP) helps prevent cell death due to the accumulation of this oxidation product in mtDNA. Although it was suspected for many years that irreparably damaged mtDNA might be targeted for degradation, only recently was clear evidence provided for this hypothesis. Therefore, multiple DNA repair pathways and controlled degradation of mtDNA function together to maintain the integrity of mitochondrial genome.

  13. Off-pump repair of a post-infarct ventricular septal defect: the 'Hamburger procedure'

    PubMed Central

    Barker, Thomas A; Ng, Alexander; Morgan, Ian S

    2006-01-01

    We report a novel off-pump technique for the surgical closure of post-infarct ventricular septal defects (VSDs). The case report describes the peri-operative management of a 76 year old lady who underwent the 'Hamburger procedure' for closure of her apical VSD. Refractory cardiogenic shock meant that traditional patch repairs requiring cardiopulmonary bypass would be poorly tolerated. We show that echocardiography guided off-pump posterior-anterior septal plication is a safe, effective method for closing post-infarct VSDs in unstable patients. More experience is required to ascertain whether this technique will become an accepted alternative to patch repairs. PMID:16722552

  14. New Technique of Exposed Glaucoma Drainage Tube Repair: Report of a Case.

    PubMed

    Berezina, Tamara L; Fechtner, Robert D; Cohen, Amir; Kim, Eliott E; Chu, David S

    2015-01-01

    We present the case of successful repair of an exposed glaucoma drainage tube by cornea graft fixation with tissue adhesive, and without subsequent coverage by adjacent conjunctiva or donor tissues. Patient with history of keratoglobus with thin cornea and sclera, and phthisical contralateral eye, underwent three unsuccessful corneal grafts followed by Boston type 1 keratoprosthesis in the right eye. Ahmed drainage device with sclera patch graft was implanted to control the intraocular pressure. Two years later the tube eroded through sclera graft and conjunctiva. Repair was performed by covering the tube with a corneal patch graft secured by tissue adhesive after the conjunctiva in this area was dissected away. The cornea graft was left uncovered due to fragility of adjacent conjunctiva. The healing of ocular and graft surfaces was complete prior to the 1 month follow-up. Conjunctival epithelium covered the corneal patch graft. At 12 months follow-up, the graft and the tube remained stable. Our report suggests that corneal patch graft fixation to the sclera by means of tissue adhesive, without closing the conjunctiva, can be considered as an effective alternative surgical approach for managing exposed glaucoma drainage tube, accompanied by adjacent conjunctiva tissue deficiency. How to cite this article: Berezina TL, Fechtner RD, Cohen A, Kim EE, Chu DS. New Technique of Exposed Glaucoma Drainage Tube Repair: Report of a Case. J Curr Glaucoma Pract 2015;9(2):62-64.

  15. Method for Qualification of Composite Repairs for Pipelines: Patch Repairs and Considerations for Cathodic Protection

    DOT National Transportation Integrated Search

    2009-12-03

    While the mechanical properties of composite repairs for pipelines have been investigated extensively, the performance of the entire metal-composite system has not been addressed with regard to corrosion of the substrate, water intrusion at the compo...

  16. Deep patch technique for landslide repair. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Helwany, B.M.

    1994-10-01

    The report describes the laboratory testing of the `USFS deep patch` technique and a CTI modification of this technique for repairing landslides with geosynthetic reinforcement. The technique involves replacing sections of roadway lost due to landslides on top of a geosynthetically-reinforced embankment. The CTI modification involves replacing the reinforced slope with a geosynthetically-reinforced retaining wall with a truncated base. Both techniques rely on the cantilevering ability of the reinforced mass to limit the load on the foundation with a high slide potential. The tests with road base showed that (1) both the USFS and CTI repair reduced effectively the adversemore » effects of local landsliding on the highway pavement by preventing crack propagation; (2) the USFS repair increased the stability of the repaired slope, which was in progressive failure, by reducing the stresses exerted on it; and (3) the CTI repair produced substantially greater stresses on its foundation due to the truncated base of the reinforced mass.« less

  17. Omental patch repair effectively treats perforated marginal ulcer following Roux-en-Y gastric bypass.

    PubMed

    Wendling, Mark R; Linn, John G; Keplinger, Kara M; Mikami, Dean J; Perry, Kyle A; Melvin, W Scott; Needleman, Bradley J

    2013-02-01

    Marginal ulcer formation remains a significant complication of Roux-en-Y gastric bypass (RYGB). Up to 1 % of all RYGB patients will develop free perforation of a marginal ulcer. Classically, this complication has required anastomotic revision; however, this approach is associated with significant morbidity. Several small series have suggested that omental patch repair may be effective. The aim of this study was to examine the management of perforated marginal ulcers following RYGB. All patients who underwent operative intervention for perforated ulcers between 2003 and 2011 were reviewed. Those with a history of RYGB with perforation of a marginal ulcer were included in the analysis. Data collected included operative approach, operative time, blood loss, length of hospital stay, complications, smoking history, and steroid or NSAID use. From January 2003 to December 2011, a total of 1,760 patients underwent RYGB at our institution. Eighteen (0.85 %) developed perforation of a marginal ulcer. Three patients' original procedure was performed at another institution. Eight patients (44 %) had at least one risk factor for ulcer formation. Treatment included omental patch repair (laparoscopic, n = 7; open, n = 9) or anastomotic revision (n = 2). Compared to anastomotic revision, omental patch repair had shorter OR time (101 ± 57 vs. 138 ± 2 min), decreased estimated blood loss (70 ± 72 vs. 250 ± 71 mL), and shorter total length of stay (5.6 ± 1.4 vs. 11.0 ± 5.7 days). Perforated marginal ulcer represents a significant complication of RYGB. Patients should be educated to reduce risk factors for perforation, as prolonged proton pump inhibitor therapy may not prevent this complication in a patient with even just one risk factor. In our sample population we found laparoscopic or open omental patch repair to be a safe and effective treatment for this condition and it was associated with decreased operative time, blood loss, and length of stay.

  18. Endoscopic observation of different repair patterns in human traumatic tympanic membrane perforations.

    PubMed

    Huang, Peng; Zhang, Shujun; Gong, Xinhong; Wang, Xuesong; Lou, Zi-Han

    2017-08-03

    In the last decade, there has been an increasing use of biomaterial patches in the regeneration of traumatic tympanic membrane perforations. The major advantages of biomaterial patches are to provisionally restore the physiological function of the middle ear, thereby immediately improving ear symptoms, and act as a scaffold for epithelium migration. However, whether there are additional biological effects on eardrum regeneration is unclear for biological material patching in the clinic. This study evaluated the healing response for different repair patterns in human traumatic tympanic membrane perforations by endoscopic observation. In total, 114 patients with traumatic tympanic membrane perforations were allocated sequentially to two groups: the spontaneous healing group (n=57) and Gelfoam patch-treated group (n=57). The closure rate, closure time, and rate of otorrhea were compared between the groups at 3 months. Ultimately, 107 patients were analyzed in the two groups (52 patients in the spontaneous healing group vs. 55 patients in the Gelfoam patch-treated group). The overall closure rate at the end of the 3 month follow-up period was 90.4% in the spontaneous healing group and 94.5% in the Gelfoam patch-treated group; the difference was not statistically significant (p>0.05). However, the total average closure time was significantly different between the two groups (26.8±9.1 days in the spontaneous healing group vs. 14.7±9.1 days in the Gelfoam patch-treated group, p<0.01). In addition, the closure rate was not significantly different between the spontaneous healing group and Gelfoam patch-treated group regardless of the perforation size. The closure time in the Gelfoam patch-treated group was significantly shorter than that in the spontaneous healing group regardless of the perforation size (small perforations: 7.1±1.6 days vs. 12.6±3.9, medium-sized perforations: 13.3±2.2 days vs. 21.8±4.2 days, and large perforations: 21.2±4.7 days vs. 38.4±5.7 days; p<0.01). In the regeneration of traumatic tympanic membrane perforations, Gelfoam patching not only plays a scaffolding role for epithelial migration, it also promotes edema and hyperplasia of granulation tissue at the edges of the perforation and accelerates eardrum healing. Copyright © 2017 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  19. The fabrication and characterization of a multi-laminate, angle-ply collagen patch for annulus fibrosus repair.

    PubMed

    McGuire, Rachel; Borem, Ryan; Mercuri, Jeremy

    2017-12-01

    One major limitation of intervertebral disc (IVD) repair is that no ideal biomaterial has been developed that effectively mimics the angle-ply collagen architecture and mechanical properties of the native annulus fibrosus (AF). Furthermore, it would be beneficial to devise a simple, scalable process by which to manufacture a biomimetic biomaterial that could function as a mechanical repair patch to be secured over a large defect in the outer AF that will support AF tissue regeneration. Such a biomaterial would: (1) enable the employment of early-stage interventional strategies to treat IVD degeneration (i.e. nucleus pulposus arthroplasty); (2) prevent IVD re-herniation in patients with large AF defects; and (3) serve as a platform to develop full-thickness AF and whole IVD tissue engineering strategies. Due to the innate collagen fibre alignment and mechanical strength of pericardium, a procedure was developed to assemble multi-laminate angle-ply AF patches derived from decellularized pericardial tissue. Patches were subsequently assessed histologically to confirm angle-ply microarchitecture, and mechanically assessed for biaxial burst strength and tensile properties. Additionally, patch cytocompatibility was evaluated following seeding with bovine AF cells. This study demonstrated the effective removal of porcine cell remnants from the pericardium, and the ability to reliably produce multi-laminate patches with angle-ply architecture using a simple assembly technique. Resultant patches demonstrated their inherent ability to resist biaxial burst pressures reminiscent of intradiscal pressures commonly borne by the AF, and exhibited tensile strength and modulus values reported for native human AF. Furthermore, the biomaterial supported AF cell viability, infiltration and proliferation. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  20. Use of composite materials, health monitoring and self-healing concepts to refurbish our civil and military infrastructure.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roach, Dennis Patrick; Delong, Waylon Anthony; White, Scott

    An unavoidable by-product of a metallic structure's use is the appearance of crack, corrosion, erosion and other flaws. Economic barriers to the replacement of these structures have created an aging civil and military infrastructure and placed even greater demands on efficient and safe repair and inspection methods. As a result of Homeland Security issues and these aging infrastructure concerns, increased attention has been focused on the rapid repair and preemptive reinforcement of structures such as buildings and bridges. This Laboratory Directed Research and Development (LDRD) program established the viability of using bonded composite patches to repair metallic structures. High modulusmore » fiber-reinforced polymer (FRP) material may be used in lieu of mechanically fastened metallic patches or welds to reinforce or repair damaged structures. Their use produces a wide array of engineering and economic advantages. Current techniques for strengthening steel structures have several drawbacks including requiring heavy equipment for installation, poor fatigue performance, and the need for ongoing maintenance due to continued corrosion attack or crack growth. The use of bonded composite doublers has the potential to correct the difficulties associated with current repair techniques and the ability to be applied where there are currently no rehabilitation options. Applications include such diverse structures as: buildings, bridges, railroad cars, trucks and other heavy machinery, steel power and communication towers, pipelines, factories, mining equipment, ships, tanks and other military vehicles. This LDRD also proved the concept of a living infrastructure by developing custom sensors and self-healing chemistry and linking this technology with the application of advanced composite materials. Structural Health Monitoring (SHM) systems and mountable, miniature sensors were designed to continuously or periodically assess structural integrity. Such systems are able to detect incipient damage before catastrophic failure occurs. The ease of monitoring an entire network of distributed sensors means that structural health assessments can occur more often, allowing operators to be even more vigilant with respect to flaw onset. In addition, the realization of smart structures, through the use of in-situ sensors, allows condition-based maintenance to be substituted for conventional time-based maintenance practices. The sensitivity and reliability of a series of sensor systems was quantified in laboratory and real-world environments. Finally, self healing methods for composite materials were evolved--using resin modules that are released in response to the onset of delaminations--so that these components can provide a living infrastructure with minimal need for human intervention. This program consisted of four related research elements: (1) design, installation, and performance assessment of composite repairs, (2) in-situ sensors for real-time health monitoring, (3) self healing of in-service damage in a repair, and (4) numerical modeling. Deployment of FRP materials and bonded joints requires proper design, suitable surface preparation methods, and adequate surveillance to ensure structural integrity. By encompassing all 'cradle-to-grave' tasks --including design, analysis, installation, durability, flaw containment, and inspection--this program is designed to firmly establish the capabilities of composite doubler repairs and introduce technology to incorporate self-monitoring and self-healing (living structures) methodologies. A proof-of-concept repair was completed on a steel highway bridge in order to demonstrate the potential of composite doubler technology for critical infrastructure use.« less

  1. Analysis of aggregate pier systems for stabilization of subgrade settlement.

    DOT National Transportation Integrated Search

    2014-12-01

    Every year, ODOT undertakes numerous pavement patching/resurfacing projects to repair pavement : distress and structural failure due to soft and/or organic soils constituting the subgrade. Other than the : temporary solution of patching/resurfacing, ...

  2. Research notes : alternate method for pothole patching.

    DOT National Transportation Integrated Search

    1998-09-01

    Typically, throw and roll pothole patches will likely fail before the pavement is resurfaced or rehabilitated. Alternatively, semi-permanent repairs are time consuming and require more people and added lane closure time. An alternate method is spray ...

  3. Bacterial genes mutL, mutS, and dcm participate in repair of mismatches at 5-methylcytosine sites.

    PubMed Central

    Lieb, M

    1987-01-01

    Certain amber mutations in the cI gene of bacteriophage lambda appear to recombine very frequently with nearby mutations. The aberrant mutations included C-to-T transitions at the second cytosine in 5'CC(A/T)GG sequences (which are subject to methylation by bacterial cytosine methylase) and in 5'CCAG and 5'CAGG sequences. Excess cI+ recombinants arising in crosses that utilize these mutations are attributable to the correction of mismatches by a bacterial very-short-patch (VSP) mismatch repair system. In the present study I found that two genes required for methyladenine-directed (long-patch) mismatch repair, mutL and mutS, also functioned in VSP mismatch repair; mutH and mutU (uvrD) were dispensable. VSP mismatch repair was greatly reduced in a dcm Escherichia coli mutant, in which 5-methylcytosine was not methylated. However, mismatches in heteroduplexes prepared from lambda DNA lacking 5-methylcytosine were repaired in dcm+ bacteria. These results indicate that the product of gene dcm has a repair function in addition to its methylase activity. PMID:2959653

  4. An Enhanced Vacuum Cure Technique for On-Aircraft Repair of Carbon-Bismaleimide Composites

    NASA Astrophysics Data System (ADS)

    Rider, Andrew N.; Baker, Alan A.; Wang, Chun H.; Smith, Graeme

    2011-06-01

    Carbon/bismaleimide (BMI) composite is increasingly employed in critical load carrying aircraft structures designed to operate at temperatures approaching 180°C. The high post-cure temperature (above 220°C) required to fully react the BMI resin, however, renders existing on-aircraft prepreg or wet layup repair methods invalid. This paper presents a new on-aircraft repair technique for carbon/BMI composites. The composite prepregs are first warm-staged to improve the ability to evacuate entrapped air. Then the patch is cured in the scarf cavity using the vacuum bag technique, followed by off-aircraft post-cure. The fully cured patch then can be bonded using a structural adhesive.

  5. The "Flat Diaphragm": Does the Degree of Curvature of the Diaphragm on Postoperative X-Ray Predict Congenital Diaphragmatic Hernia Recurrence?

    PubMed

    Short, Heather L; Clifton, Matthew S; Arps, Kelly; Travers, Curtis; Loewen, Jonathan; Schlager, Avraham

    2018-04-01

    The appearance of the diaphragmatic curvature and the rib insertion level of the diaphragm on postoperative chest X-ray (CXR) may predict recurrence. Our purpose was to examine the relationship between the curvature of the diaphragm on postoperative CXR and recurrence. We performed a retrospective review of left-sided, Bochdalek congenital diaphragmatic hernia (CDH) surgical repairs from 2004 to 2015 at a single institution. We developed a tool to measure the flatness of the diaphragm on postoperative CXR, termed the diaphragmatic curvature index (τ). The primary outcome of interest was recurrence after surgical repair. Of the 127 patients identified, 54% (n = 69) had a primary repair, while 46% (n = 58) required a patch repair. The overall recurrence rate was 21.3% (n = 27). There was no difference in median lateral rib insertion level in patients with and without recurrence or those who had a primary or patch repair. The overall median diaphragmatic curvature index was 6.29 (interquartile range [IQR] 5.30-8.09) and was not significantly different among patients who had a recurrence (6.00, IQR 5.34-8.24) and those who did not (6.46, IQR 5.24-8.07) (P = .853). Within the primary repair group (6.34 versus 6.93, P = .84) and the patch repair group (5.59 versus 6.18, P = .46), the median diaphragmatic curvature index was not different among patients who had a recurrence and those who did not. A flat appearance of the diaphragm on postoperative CXR as measured by the median diaphragmatic curvature index (τ) is not associated with recurrence. The shape of the diaphragm on CXR after CDH repair may not be predictive of recurrence as previously thought.

  6. Damage Tolerant Analysis of Cracked Al 2024-T3 Panels repaired with Single Boron/Epoxy Patch

    NASA Astrophysics Data System (ADS)

    Mahajan, Akshay D.; Murthy, A. Ramachandra; Nanda Kumar, M. R.; Gopinath, Smitha

    2018-06-01

    It is known that damage tolerant analysis has two objectives, namely, remaining life prediction and residual strength evaluation. To achieve the these objectives, determination of accurate and reliable fracture parameter is very important. XFEM methodologies for fatigue and fracture analysis of cracked aluminium panels repaired with different patch shapes made of single boron/epoxy have been developed. Heaviside and asymptotic crack tip enrichment functions are employed to model the crack. XFEM formulations such as displacement field formulation and element stiffness matrix formulation are presented. Domain form of interaction integral is employed to determine Stress Intensity Factor of repaired cracked panels. Computed SIFs are incorporated in Paris crack growth model to predict the remaining fatigue life. The residual strength has been computed by using the remaining life approach, which accounts for both crack growth constants and no. of cycles to failure. From the various studies conducted, it is observed that repaired panels have significant effect on reduction of the SIF at the crack tip and hence residual strength as well as remaining life of the patched cracked panels are improved significantly. The predicted remaining life and residual strength will be useful for design of structures/components under fatigue loading.

  7. Partial-depth repair of jointed PCC pavements : cast-in-place and precast procedures.

    DOT National Transportation Integrated Search

    1977-01-01

    The installation of durable patches on jointed portland cement concrete pavement using several types of cast-in-place concrete, is described. The recommended procedures for pavement preparation and patch installation are given, and additional mainten...

  8. Repair of Tricuspid Valve Leaflet With CardioCel Patch After Traumatic Tricuspid Regurgitation.

    PubMed

    Konstantinidou, Maria Kalliopi; Moat, Neil

    2017-09-01

    Posttraumatic tricuspid valve regurgitation (TR) is a rare entity and is almost always associated with blunt chest trauma. It is usually identified by transthoracic echocardiography after the manifestation of clinical symptoms of heart failure. Treatment varies from long-term medical therapy and observation to surgical correction with tricuspid valve replacement or repair. We describe the case of a 26-year-old man who was involved in a major road traffic accident and was referred for surgical repair a year later because of severe posttraumatic TR. The tricuspid valve was successfully reconstructed with a CardioCel patch, Gore-Tex neochordae, and a tricuspid ring. The patient recovered well. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  9. Base Excision Repair

    PubMed Central

    Krokan, Hans E.; Bjørås, Magnar

    2013-01-01

    Base excision repair (BER) corrects DNA damage from oxidation, deamination and alkylation. Such base lesions cause little distortion to the DNA helix structure. BER is initiated by a DNA glycosylase that recognizes and removes the damaged base, leaving an abasic site that is further processed by short-patch repair or long-patch repair that largely uses different proteins to complete BER. At least 11 distinct mammalian DNA glycosylases are known, each recognizing a few related lesions, frequently with some overlap in specificities. Impressively, the damaged bases are rapidly identified in a vast excess of normal bases, without a supply of energy. BER protects against cancer, aging, and neurodegeneration and takes place both in nuclei and mitochondria. More recently, an important role of uracil-DNA glycosylase UNG2 in adaptive immunity was revealed. Furthermore, other DNA glycosylases may have important roles in epigenetics, thus expanding the repertoire of BER proteins. PMID:23545420

  10. Laparoscopic versus open operation for perforated peptic ulcer in pediatric patients: A 10-year experience.

    PubMed

    Wong, Carol W Y; Chung, Patrick H Y; Tam, Paul K H; Wong, Kenneth K Y

    2015-12-01

    Perforated peptic ulcer (PPU) is a relatively uncommon condition in children. We aim to evaluate and compare the outcomes of laparoscopic omental patch repair versus open repair for PPU in pediatric patients. Children who underwent omental patch repair for PPU from 2004 to 2014 in our hospital were reviewed retrospectively. Patient demographics, perioperative as well as intraoperative details and surgical outcomes, were analyzed. Thirteen patients were identified, and all presented with abdominal pain. The median age of the study group was 14.9years (range 6.3 to 18.4years). Radiological evidence of pneumoperitoneum on erect chest x-ray (CXR) was found only in five patients (38.5%). None of the patients had a known history of peptic ulcer disease. Diagnosis other than PPU was made in five patients preoperatively. Laparoscopic repair was attempted in eight patients with one of them requiring conversion. There was no significant difference in patient demographics when compared with the open repair group. The perforation site was in the duodenum in 11 patients and in the antrum in two patients. The mean size of perforation was larger in the open repair group (p=0.005). Although the operating time was longer in the laparoscopic group (p=0.51), the length of hospital stay was significantly shorter (p=0.048). Only two patient diseases were Helicobacter pylori related. Clinical features of perforated peptic ulcer in children are different from adults. Risk factors are less frequently identified. Laparoscopic omental patch repair is a feasible surgical option and is associated with satisfactory outcomes in pediatric practice. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Patch-Augmented Rotator Cuff Repair and Superior Capsule Reconstruction

    PubMed Central

    Petri, M.; Greenspoon, J.A.; Moulton, S.G.; Millett, P.J.

    2016-01-01

    Background: Massive rotator cuff tears in active patients with minimal glenohumeral arthritis remain a particular challenge for the treating surgeon. Methods: A selective literature search was performed and personal surgical experiences are reported. Results: For patients with irreparable rotator cuff tears, a reverse shoulder arthroplasty or a tendon transfer are often performed. However, both procedures have rather high complication rates and debatable long-term results, particularly in younger patients. Therefore, patch-augmented rotator cuff repair or superior capsule reconstruction (SCR) have been recently developed as arthroscopically applicable treatment options, with promising biomechanical and early clinical results. Conclusion: For younger patients with irreparable rotator cuff tears wishing to avoid tendon transfers or reverse total shoulder arthroplasty, both patch-augmentation and SCR represent treatment options that may delay the need for more invasive surgery. PMID:27708733

  12. Bonding agents for portland cement concrete and mortar.

    DOT National Transportation Integrated Search

    1983-01-01

    Structural repairs of bridge piers and abutements require patching concrete : used depends upon the depth of the patch to be made. In some instances, the : use of a liquid bonding agent has been specified in the mixes as well as in a : grout scrubbed...

  13. Pipe inspection and repair system

    NASA Technical Reports Server (NTRS)

    Schempf, Hagen (Inventor); Mutschler, Edward (Inventor); Chemel, Brian (Inventor); Boehmke, Scott (Inventor); Crowley, William (Inventor)

    2004-01-01

    A multi-module pipe inspection and repair device. The device includes a base module, a camera module, a sensor module, an MFL module, a brush module, a patch set/test module, and a marker module. Each of the modules may be interconnected to construct one of an inspection device, a preparation device, a marking device, and a repair device.

  14. Repairing Hard-to-Reach Cracks in Heat-Exchanger Tubes

    NASA Technical Reports Server (NTRS)

    Mills, R. C., Sr.; Duesberg, J.

    1986-01-01

    Inaccessible leaks repaired from accessible side of tube. Fish-Mouth insert placed in cut in leaky heat-exchanger tube. Insert welded or brazed to tube, and remaining open area of cut patched. Method developed for repairing leaks in nozzle coolant tubes of Space Shuttle main engine. Method also used on other types of tubular heat exchangers.

  15. Evaluation of a tissue-engineered bovine pericardial patch in paediatric patients with congenital cardiac anomalies: initial experience with the ADAPT-treated CardioCel(R) patch.

    PubMed

    Neethling, William M L; Strange, Geoff; Firth, Laura; Smit, Francis E

    2013-10-01

    This study evaluated the safety, efficacy and clinical performance of the tissue-engineered ADAPT® bovine pericardial patch (ABPP) in paediatric patients with a range of congenital cardiac anomalies. In this single-centre, prospective, non-randomized clinical study, paediatric patients underwent surgery for insertion of the ABPP. Primary efficacy measures included early (<30 day) morbidity; incidence of device-related complications; haemodynamic performance derived from echocardiography assessment at 6- and 12-month follow-up and magnetic resonance imaging findings in 10 randomly selected patients at 12 months. Secondary measures included device-handling characteristics; shape and sizing characteristics and perioperative implant complications. The Aristotle complexity scoring system was used to score the complexity level of all surgical procedures. Patients completing the 12-month study were eligible to enter a long-term evaluation study. Between April 2008 and September 2009, the ABPP was used in 30 paediatric patients. In the 30-day postoperative period, no graft-related morbidity was observed. In total, there were 5 deaths (2 in the 30-day postoperative period and 3 within the first 6 postoperative months). All deaths were deemed due to comorbid non-graft-related events. Echocardiography assessment at 6 and 12 months revealed intact anatomical and haemodynamically stable repairs without any visible calcification of the patch. Magnetic resonance imaging assessment in 10 patients at 12 months revealed no signs of calcification. Fisher's exact test demonstrated that patients undergoing more complex, higher risk surgical repairs (Aristotle complexity score >8) were significantly more likely to die (P = 0.0055, 58% survival compared with 100% survival for less complex surgical repairs). In 19 patients, echocardiographic data were available at 18-36 months with no evidence of device calcification, infection, thromboembolic events or device failure. This study demonstrates the safety and efficacy of this engineered bovine pericardial patch as a cardiovascular substitute for surgical repair of both simple and more complex congenital cardiac defects.

  16. Effectiveness of sacrificial anodes in high-resistivity shotcrete repairs.

    DOT National Transportation Integrated Search

    2005-01-01

    This study investigated the use of discrete sacrificial anodes to improve the durability and extend the life of a shotcrete patch repair in a column. Three columns were used in the investigation. In two columns, anodes were placed around the perimete...

  17. Analysis of repair and PCNA complex formation induced by ionizing radiation in human fibroblast cell lines.

    PubMed

    Karmakar, P; Balajee, A S; Natarajan, A T

    2001-05-01

    Proliferating cell nuclear antigen (PCNA), an auxiliary factor for DNA polymerase delta and epsilon, is involved in both DNA replication and repair. Previous studies in vitro have demonstrated the requirement of PCNA in the resynthesis step of nucleotide excision repair (NER) and base excision repair (BER). Using a native chromatin template isolated under near physiological conditions, we have analysed the involvement of PCNA in the BER pathway in different NER defective human cell lines. The repair sites and PCNA were visualized by indirect immunolabelling followed by fluorescence microscopy. The results indicate that exposure to X-rays triggers the induction of PCNA in all the three human fibroblast cell lines studied, namely normal, xeroderma pigmentosum group A (XP-A) and Cockayne syndrome group B (CS-B). In all the cell lines, induction of PCNA and repair patches occurred in a dose- and time-dependent fashion. Induction of repair patches in NER-deficient XP-A cells suggests that the X-ray-induced lesions are largely repaired via the BER pathway involving PCNA as one of the key components of this pathway. X-ray-induced repair synthesis was greatly inhibited by treatment of cells with DNA polymerase inhibitors aphidicolin and cytosine arabinoside. Interestingly, inhibition of repair resynthesis did not affect the intensity of PCNA staining in X-irradiated cells indicating that the PCNA may be required for the BER pathway at a step preceding the resynthesis step.

  18. Repair of extrahepatic bile duct defect using a collagen patch in a Swine model.

    PubMed

    Tao, Liang; Li, Qiang; Ren, Haozhen; Chen, Bing; Hou, Xianglin; Mou, Lingjun; Zhou, Siqiao; Zhou, Jianxin; Sun, Xitai; Dai, Jianwu; Ding, Yitao

    2015-04-01

    Extrahepatic bile duct (EBD) injury can happen during surgery. To repair a defect of the EBD and prevent postoperative biliary complications, a collagen membrane was designed. The collagen material was porous, biocompatible, and degradable and could maintain its shape in bile soaking for about 4 weeks. The goal was to induce rapid bile duct tissue regeneration. Twenty Chinese experimental hybrid pigs were used in this study and divided into a patch group and a control group. A spindle-shaped defect (20 mm × 6 mm) was made in the anterior wall of the lower EBD in the swine model, and then the defect was reconstructed using a collagen patch with a drainage tube and wrapped with greater omentum. Ultrasound was performed at 2, 4, 8, and 12 weeks postoperatively. Liver function tests and white blood cell count (WBC) were measured. Hematoxylin-eosin staining, cytokeratin 7 immunohistochemical staining, and Van Gieson's staining of EBD were used. The diameter and thickness of the EBD at the graft site were measured. There was no significant difference in liver function tests or WBC in the patch group compared with the control group. No evidence of leakage or stricture was observed, but some pigs developed biliary sludge or stone at 4 and 8 weeks. The drainage tube was lost within 12 weeks. The neo-EBD could withstand normal biliary pressure 2 weeks after surgery. Histological study showed the accessory glands and epithelial cells gradually regenerated at graft sites from 4 weeks, with increasing vessel infiltration and decreasing inflammation. The collagen fibers became regular with full coverage of epithelial cells. The statistical analysis of diameter and thickness showed no stricture formation at the graft site, but the EBD wall was slightly thicker than in the normal bile duct due to collagen fiber deposition. The structure of the neo-EBD was similar to that of the normal EBD. The collagen membrane patch associated with a drainage tube and wrapped with greater omentum effectively induced the regeneration of the EBD defect within 12 weeks. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  19. Field evaluation of corrosion inhibitors for concrete : interim report 2, evaluation of installation and initial condition of bridge repairs done with corrosion-inhibiting admixtures and topical treatments.

    DOT National Transportation Integrated Search

    1999-06-01

    Four bridge decks were overlayed and patched and one bridge pier was patched using concrete with and without corrosion inhibiting admixtures. Some concrete surfaces received topically applied corrosion-inhibiting treatments prior to placement of the ...

  20. Annexins in plasma membrane repair.

    PubMed

    Boye, Theresa Louise; Nylandsted, Jesper

    2016-10-01

    Disruption of the plasma membrane poses deadly threat to eukaryotic cells and survival requires a rapid membrane repair system. Recent evidence reveal various plasma membrane repair mechanisms, which are required for cells to cope with membrane lesions including membrane fusion and replacement strategies, remodeling of cortical actin cytoskeleton and vesicle wound patching. Members of the annexin protein family, which are Ca2+-triggered phospholipid-binding proteins emerge as important components of the plasma membrane repair system. Here, we discuss the mechanisms of plasma membrane repair involving annexins spanning from yeast to human cancer cells.

  1. The use of epoxy patch grafts for the repair of experimentally-created diaphragmatic defects in dogs.

    PubMed

    Matsumoto, H; Oguchi, Y; Miyake, Y; Masuda, Y; Masada, S; Kuno, Y; Shibahara, I; Takashima, K; Yamane, H; Yamagata, S; Noishiki, Y; Yamane, Y

    1996-07-01

    Canine pericardium which had been treated with polyepoxy compounds (Denacol EX-313) was used as a patch graft for the correction of experimentally-created diaphragmatic defects in five dogs belonging to the same litter. Clinical, macroscopic and histological examinations were conducted every month up to five months after suturing of the patch graft. Clinical examination of the patch graft showed no apparent abnormalities. Macroscopic examination conducted during autopsy showed that the patch graft maintained adequate elasticity for five months after suturing, the surface of the patch graft was covered with a thin membrane and neovascularization was observed. Histological examination showed that the surface of the patch graft was covered with a thin membrane. Inflammatory tissue reactions were observed at one month, but gradually decreased from the second month onwards. In addition, the patch graft had excellent tissue affinity.

  2. Strength and Density of Geopolymer Mortar Cured at Ambient Temperature for Use as Repair Material

    NASA Astrophysics Data System (ADS)

    Warid Wazien, A. Z.; Bakri Abdullah, Mohd Mustafa Al; Abd. Razak, Rafiza; Mohd Remy Rozainy, M. A. Z.; Faheem Mohd Tahir, Muhammad

    2016-06-01

    Geopolymers produced by synthesizing aluminosilicate source materials with an alkaline activator solution promised an excellent properties akin to the existing construction material. This study focused on the effect of various binder to sand ratio on geopolymer mortar properties. Mix design of geopolymer mortar was produced using NaOH concentration of 12 molars, ratio of fly ash/alkaline activator and ratio Na2SiO3/NaOH of 2.0 and 2.5 respectively. Samples subsequently ware cured at ambient temperature. The properties of geopolymer mortar were analysed in term of compressive strength and density at different period which are on the 3rd and 7th day of curing. Experimental results revealed that the addition of sand slightly increase the compressive strength of geopolymer. The optimum compressive strength obtained was up to 31.39 MPa on the 7th day. The density of geopolymer mortar was in the range between 2.0 g/cm3 to 2.23 g/cm3. Based on this findings, the special properties promoted by geopolymer mortar display high potential to be implemented in the field of concrete patch repair.

  3. Application of Circular Patch Plasty (Dor Procedure) or Linear Repair Techniques in the Treatment of Left Ventricular Aneurysms.

    PubMed

    Kaya, Ugur; Çolak, Abdurrahim; Becit, Necip; Ceviz, Munacettin; Kocak, Hikmet

    2018-01-01

    The aim of this study was to evaluate early clinical outcomes and echocardiographic measurements of the left ventricle in patients who underwent left ventricular aneurysm repair using two different techniques associated to myocardial revascularization. Eighty-nine patients (74 males, 15 females; mean age 58±8.4 years; range: 41 to 80 years) underwent post-infarction left ventricular aneurysm repair and myocardial revascularization performed between 1996 and 2016. Ventricular reconstruction was performed using endoventricular circular patch plasty (Dor procedure) (n=48; group A) or linear repair technique (n=41; group B). Multi-vessel disease in 55 (61.7%) and isolated left anterior descending (LAD) disease in 34 (38.2%) patients were identified. Five (5.6%) patients underwent aneurysmectomy alone, while the remaining 84 (94.3%) patients had aneurysmectomy with bypass. The mean number of grafts per patient was 2.1±1.2 with the Dor procedure and 2.9±1.3 with the linear repair technique. In-hospital mortality occurred in 4.1% and 7.3% in group A and group B, respectively (P>0.05). The results of our study demonstrate that post-infarction left ventricular aneurysm repair can be performed with both techniques with acceptable surgical risk and with satisfactory hemodynamic improvement.

  4. Stem cells are dispensable for lung homeostasis but restore airways after injury.

    PubMed

    Giangreco, Adam; Arwert, Esther N; Rosewell, Ian R; Snyder, Joshua; Watt, Fiona M; Stripp, Barry R

    2009-06-09

    Local tissue stem cells have been described in airways of the lung but their contribution to normal epithelial maintenance is currently unknown. We therefore developed aggregation chimera mice and a whole-lung imaging method to determine the relative contributions of progenitor (Clara) and bronchiolar stem cells to epithelial maintenance and repair. In normal and moderately injured airways chimeric patches were small in size and not associated with previously described stem cell niches. This finding suggested that single, randomly distributed progenitor cells maintain normal epithelial homeostasis. In contrast we found that repair following severe lung injury resulted in the generation of rare, large clonal cell patches that were associated with stem cell niches. This study provides evidence that epithelial stem cells are dispensable for normal airway homeostasis. We also demonstrate that stem cell activation and robust clonal cellular expansion occur only during repair from severe lung injury.

  5. The biomechanical effects of polytetrafluoroethylene suture augmentations in lateral-row rotator cuff repairs in an ovine model.

    PubMed

    Beimers, Lijkele; Lam, Patrick H; Murrell, George A C

    2014-10-01

    This study investigated the biomechanical effects of expanded polytetrafluoroethylene (ePTFE) suture augmentation patches in rotator cuff repair constructs. The infraspinatus tendon in 24 cadaveric ovine shoulders was repaired using an inverted horizontal mattress suture with 2 knotless bone anchors (ArthroCare, Austin, TX, USA) in a lateral-row configuration. Four different repair groups (6 per group) were created: (1) standard repair using inverted horizontal mattress sutures, (2) repair with ePTFE suture augmentations on the bursal side of the tendon, (3) repair with ePTFE suture augmentations on the articular side, and, (4) repair with ePTFE suture augmentations on both sides of the tendon. Footprint contact pressure, stiffness, and the load to failure of the repair constructs were measured. Repairs with ePTFE suture augmentations on the bursal side exerted significantly more footprint contact pressure (0.40 ± 0.01 MPa) than those on the articular side (0.34 ± 0.02 MPa, P = .04) and those on both sides (0.33 ± 0.02 MPa, P = .01). At 15 degrees of abduction, ePTFE-augmented repairs on the bursal side had higher footprint contact pressure (0.26 ± 0.03 MPa) compared with standard repairs (0.15 ± 0.02 MPa, P = .01) and with ePTFE-augmented repairs on the articular side (0.18 ± 0.02 MPa, P = .03). The ePTFE-augmented repairs on the bursal side demonstrated significantly higher failure loads (178 ± 18 N) than standard repairs (120 ± 17 N, P = .04). Inverted horizontal mattress sutures augmented with ePTFE patches on the bursal side of the tendon enhanced footprint contact pressures and the ultimate load to failure of lateral-row rotator cuff repairs in an ovine model. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  6. Long-term successful arthroscopic repair of large and massive rotator cuff tears with a functional and degradable reinforcement device.

    PubMed

    Proctor, Christopher S

    2014-10-01

    Rotator cuff repair is a procedure with varying outcomes, and there has been subsequent interest in devices that reinforce the repair and enhance structural and functional outcomes. The objective of this study was to determine these outcomes for arthroscopic repair of large and massive rotator cuff tears augmented with a synthetic absorbable mesh designed specifically for reinforcement of tendon repair by imaging and clinical assessments. Consecutive arthroscopic repairs were performed on 18 patients with large to massive rotator cuff tears by use of a poly-l-lactic acid synthetic patch as a reinforcement device and fixation with 4 sutures. Patients were assessed preoperatively and at 6 months, 12 months, and a mean of 42 months after surgery by the American Shoulder and Elbow Surgeons (ASES) shoulder score to evaluate clinical performance and at 12 months by ultrasound to assess structural repair. Ultrasound showed that 15 of 18 patients had intact rotator cuff repair at 12 months; at 42 months, an additional patient had a failed repair. Patients showed improvement in the ASES shoulder score from 25 preoperatively to 71 at 12 months and 70 at 42 months after surgery. Patients with intact rotator cuff (n = 14) at 42 months had an ASES shoulder score of 82. The poly-l-lactic acid bioabsorbable patch designed specifically to reinforce the surgical repair of tendons supported successful repair of large to massive rotator cuff tears in 83% of patients at 12 months after surgery and 78% of patients at 42 months after surgery, with substantial functional improvement. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  7. Repair Types, Procedures - Part 1

    DTIC Science & Technology

    2010-05-01

    Affordable Combat Aircraft, AGARD - CP -600, 1997. [17] Helbling J, Grover R and Ratwani M. M “Analysis and Structural Test of Composite Reinforcement to...considered suitable for the composite patch repair of aluminum structure. Ductile adhesives such as FM- 73 are preferred over brittle adhesives Repair Types...zone. A proper cure cycle is followed as prescribed by the adhesive manufacturer. For FM- 73 adhesive cure at 2500F (1210C) for 120 minutes is

  8. A rapid non-radioactive technique for measurement of repair synthesis in primary human fibroblasts by incorporation of ethynyl deoxyuridine (EdU).

    PubMed

    Limsirichaikul, Siripan; Niimi, Atsuko; Fawcett, Heather; Lehmann, Alan; Yamashita, Shunichi; Ogi, Tomoo

    2009-03-01

    Xeroderma pigmentosum (XP) is an autosomal recessive genetic disorder. Afflicted patients show extreme sun-sensitivity and skin cancer predisposition. XP is in most cases associated with deficient nucleotide excision repair (NER), which is the process responsible for removing photolesions from DNA. Measuring NER activity by nucleotide incorporation into repair patches, termed 'unscheduled DNA synthesis (UDS)', is one of the most commonly used assays for XP-diagnosis and NER research. We have established a rapid and accurate procedure for measuring UDS by replacement of thymidine with 5-ethynyl-2'-deoxyuridine (EdU). EdU incorporated into repair patches can be directly conjugated to fluorescent azide derivatives, thereby obviating the need for either radiolabeled thymidine or denaturation and antibody detection of incorporated bromodeoxyuridine (BrdU). We demonstrate that the EdU incorporation assay is compatible with conventional techniques such as immunofluorescent staining and labeling of cells with micro-latex beads. Importantly, we can complete the entire UDS assay within half a day from preparation of the assay coverslips; this technique may prove useful as a method for XP diagnosis.

  9. A Comparison of Electrospun Polymers Reveals Poly(3-Hydroxybutyrate) Fiber as a Superior Scaffold for Cardiac Repair

    PubMed Central

    Castellano, Delia; Blanes, María; Marco, Bruno; Cerrada, Inmaculada; Ruiz-Saurí, Amparo; Pelacho, Beatriz; Araña, Miriam; Montero, Jose A.; Cambra, Vicente; Prosper, Felipe

    2014-01-01

    The development of biomaterials for myocardial tissue engineering requires a careful assessment of their performance with regards to functionality and biocompatibility, including the immune response. Poly(3-hydroxybutyrate) (PHB), poly(e-caprolactone) (PCL), silk, poly-lactic acid (PLA), and polyamide (PA) scaffolds were generated by electrospinning, and cell compatibility in vitro, and immune response and cardiac function in vitro and in vivo were compared with a noncrosslinked collagen membrane (Col) control material. Results showed that cell adhesion and growth of mesenchymal stem cells, cardiomyocytes, and cardiac fibroblasts in vitro was dependent on the polymer substrate, with PHB and PCL polymers permitting the greatest adhesion/growth of cells. Additionally, polymer substrates triggered unique expression profiles of anti- and pro-inflammatory cytokines in human peripheral blood mononuclear cells. Implantation of PCL, silk, PLA, and PA patches on the epicardial surface of healthy rats induced a classical foreign body reaction pattern, with encapsulation of polymer fibers and induction of the nonspecific immune response, whereas Col and PHB patches were progressively degraded. When implanted on infarcted rat heart, Col, PCL, and PHB reduced negative remodeling, but only PHB induced significant angiogenesis. Importantly, Col and PHB modified the inflammatory response to an M2 macrophage phenotype in cardiac tissue, indicating a more beneficial reparative process and remodeling. Collectively, these results identify PHB as a superior substrate for cardiac repair. PMID:24564648

  10. Marginal ulcer perforation: a single center experience.

    PubMed

    Natarajan, S K; Chua, D; Anbalakan, K; Shelat, V G

    2017-10-01

    Marginal ulcer (MU) is defined as ulcer on the jejunal side of the gastrojejunostomy (GJ) anastomosis. Most MUs are managed medically but those with complications like bleeding or perforation require intervention. It is recommended that GJ anastomosis be revised in patients with MU perforation (MUP). The aim of this case series is to study the clinical presentation and management of MUP. Three hundred and thirty-two patients who underwent emergency surgery for perforated peptic ulcer at a single center were studied over a period of 5 years. Nine patients (2.7 %) presented with MUP. GJ was previously done for either complicated peptic ulcer (n = 4) or for suspected gastric malignancy (n = 5). Two patients had previously completed H. pylori therapy. None of the patients presented with septic shock. MU was on the jejunal side of GJ in all patients. The median MUP size was 10 mm. Four patients (44.4 %) had omental patch repair, three (33.3 %) had primary closure, and one each had revision of GJ and jejunal serosal patch repair. There were no leaks, intra-abdominal abscess or reoperation and no malignancies. MUP patients do not present with septic shock. Omental patch repair or primary closure is sufficient enough. Revision of Billroth-II-GJ into Roux-en-Y-GJ is not mandatory.

  11. Patch-Augmented Latissimus Dorsi Transfer and Open Reduction–Internal Fixation of Unstable Os Acromiale for Irreparable Massive Posterosuperior Rotator Cuff Tear

    PubMed Central

    Petri, Maximilian; Greenspoon, Joshua A.; Bhatia, Sanjeev; Millett, Peter J.

    2015-01-01

    Latissimus dorsi transfer is a reasonable treatment option for massive posterosuperior rotator cuff tears that can substantially improve chronically painful and dysfunctional shoulders. This report and accompanying video describe the treatment of an active 43-year-old man with severe pain and weakness in the right shoulder after 3 failed rotator cuff repairs. Preoperative imaging showed a massive posterosuperior rotator cuff tear retracted to the glenoid as well as a hypermobile os acromiale likely causing dynamic impingement and recurrent rotator cuff tears. After diagnostic arthroscopy, the latissimus tendon is harvested and augmented with a 3-mm human acellular dermal patch (ArthroFlex; Arthrex, Naples, FL). The native rotator cuff tissue is repaired as much as possible, and the latissimus tendon is passed underneath the deltoid and posterior to the teres minor. The patch-augmented tendon is then integrated into a double-row SpeedBridge repair of eight 4.75-mm BioComposite SwiveLock anchors (Arthrex). The bony surface of the os acromiale is prepared and then fixed to the acromion with 2 cannulated partially threaded screws and additional tension-band wiring. Postoperative rehabilitation initially focuses on early passive range of motion, followed by active and active-assisted motion and a biofeedback program starting at 6 weeks postoperatively. PMID:26697309

  12. Laparoscopic versus Open Omental Patch Repair for Early Presentation of Perforated Peptic Ulcer: Matched Retrospective Cohort Study.

    PubMed

    Lee, Daniel Jin Keat; Ye, MaDong; Sun, Keith Haozhe; Shelat, Vishalkumar G; Koura, Aaryan

    2016-01-01

    Introduction. The aim of this study was to compare the outcomes between laparoscopic and open omental patch repair (LOPR versus OR) in patients with similar presentation of perforated peptic ulcer (PPU). The secondary aim was to evaluate the outcomes according to the severity of peritonitis. Methods. All patients who underwent omental patch repair at two university-affiliated institutes between January 2010 and December 2014 were reviewed. Matched cohort between LOPR and OR groups was achieved by only including patients that had ulcer perforation <2 cm in size and symptoms occurring <48 hours. Outcome measures were defined in accordance with length of stay (LOS), postoperative complications, and mortality. Results. 148 patients met the predefined inclusion criteria with LOPR performed in 40 patients. Outcome measures consistently support laparoscopic approach but only length of hospital stay (LOS) achieved statistical significance (LOPR 4 days versus OR 5 days, p < 0.01). In a subgroup analysis of patients with MPI score >21, LOPR is also shown to benefit, particularly resulting in significant shorter LOS (4 days versus 11 days, p < 0.01). Conclusion. LOPR offers improved short-term outcomes in patients who present within 48 hours and with perforation size <2 cm. LOPR also proved to be more beneficial in high MPI cases.

  13. Laparoscopic versus Open Omental Patch Repair for Early Presentation of Perforated Peptic Ulcer: Matched Retrospective Cohort Study

    PubMed Central

    Sun, Keith Haozhe; Koura, Aaryan

    2016-01-01

    Introduction. The aim of this study was to compare the outcomes between laparoscopic and open omental patch repair (LOPR versus OR) in patients with similar presentation of perforated peptic ulcer (PPU). The secondary aim was to evaluate the outcomes according to the severity of peritonitis. Methods. All patients who underwent omental patch repair at two university-affiliated institutes between January 2010 and December 2014 were reviewed. Matched cohort between LOPR and OR groups was achieved by only including patients that had ulcer perforation <2 cm in size and symptoms occurring <48 hours. Outcome measures were defined in accordance with length of stay (LOS), postoperative complications, and mortality. Results. 148 patients met the predefined inclusion criteria with LOPR performed in 40 patients. Outcome measures consistently support laparoscopic approach but only length of hospital stay (LOS) achieved statistical significance (LOPR 4 days versus OR 5 days, p < 0.01). In a subgroup analysis of patients with MPI score >21, LOPR is also shown to benefit, particularly resulting in significant shorter LOS (4 days versus 11 days, p < 0.01). Conclusion. LOPR offers improved short-term outcomes in patients who present within 48 hours and with perforation size <2 cm. LOPR also proved to be more beneficial in high MPI cases. PMID:27722200

  14. Long-term outcomes of reoperations following repair of partial atrioventricular septal defect.

    PubMed

    Buratto, Edward; Ye, Xin Tao; Bullock, Andrew; Kelly, Andrew; d'Udekem, Yves; Brizard, Christian P; Konstantinov, Igor E

    2016-08-01

    Partial atrioventricular septal defect (pAVSD) is repaired with excellent long-term survival. However, up to 25% of patients require reoperations. This study reviews results of reoperation following pAVSD repair at a single institution. From 1975 to 2012, 40 patients (16%, 40/246) underwent reoperation following pAVSD repair at the study institution. The data were retrospectively reviewed. The mean time to reoperation was 5.4 ± 5.8 years. The most common reoperations were left atrioventricular valve (LAVV) surgery (78%, 31/40) and resection of left ventricular outflow tract obstruction (20%, 8/40). The most common cause for LAVV surgery was regurgitation through the cleft (58%, 18/31), followed by central regurgitation (29%, 9/31). Most cases of LAVV regurgitation were treated by repair (77%, 24/31), rather than replacement (23%, 7/31). Since the introduction of a patch augmentation technique for LAVV repair in 1998, the rate of repair has increased from 54 to 94% (P = 0.012). The early mortality rate was 2.5% (1/40). The survival rate was 90% (95% CI: 76-96) at 10 years and 83% (95% CI: 60-94) at 20 years. The rate of freedom from further reoperation was 66% (95% CI: 46-80) at 10- and 20-year follow-up. The most common cause for reoperation following pAVSD repair was LAVV regurgitation through the LAVV cleft. Reoperation is performed with survival comparable to that of primary pAVSD repair, yet the rate of further reoperations remains high. The patch augmentation technique for LAVVR has significantly increased the rate of successful LAVV repair. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  15. Biocompatibility evaluation of cigarette and carbon papers used in repair of traumatic tympanic membrane perforations: experimental study.

    PubMed

    Altuntaş, Emine Elif; Sümer, Zeynep

    2013-01-01

    The purposes of this study were to investigate the biocompatibility of two different paper patches (carbon and cigarette papers) and compare the adhesion and proliferation features of L929 fibroblast cells by using 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide (MTT Test) test and scanning electron microscopy (SEM). In this study, time-dependent cytotoxic effects of cigarette and carbon papers used in repairing small traumatic TM perforations were investigated in vitro by using MTT test. And also adhesion and spreading of cells over disk surface were observed by SEM. Cytotoxicity test carried out by MTT analysis on leakage products collected from two types of paper patches at the end of 24 and 48 h revealed no cytotoxicity (P > 0.05). In SEM studies, it was observed that cells started to proliferate over disk surface as a result of 48-h incubation, and SEM revealed that the cell proliferation over cigarette paper was more compared to the one over carbon paper. We believe that this is the first study where biocompatibility and adhesion features of carbon and cigarette paper have been studied by using L929 fibroblast cell culture. As a result, biocompatibility of cigarette paper and also whether cigarette paper was superior to carbon paper in cell attachment and biocompatibility were studied. It was found, by MTT test and SEM test, that cigarette paper had a higher biocompatibility and cell attachment, and thus cigarette paper should be the patch to be preferred in cases where TM perforations are repaired by paper-patch method.

  16. Implantation of the Medtronic Harmony Transcatheter Pulmonary Valve Improves Right Ventricular Size and Function in an Ovine Model of Postoperative Chronic Pulmonary Insufficiency.

    PubMed

    Schoonbeek, Rosanne C; Takebayashi, Satoshi; Aoki, Chikashi; Shimaoka, Toru; Harris, Matthew A; Fu, Gregory L; Kim, Timothy S; Dori, Yoav; McGarvey, Jeremy; Litt, Harold; Bouma, Wobbe; Zsido, Gerald; Glatz, Andrew C; Rome, Jonathan J; Gorman, Robert C; Gorman, Joseph H; Gillespie, Matthew J

    2016-10-01

    Pulmonary insufficiency is the nexus of late morbidity and mortality after transannular patch repair of tetralogy of Fallot. This study aimed to establish the feasibility of implantation of the novel Medtronic Harmony transcatheter pulmonary valve (hTPV) and to assess its effect on pulmonary insufficiency and ventricular function in an ovine model of chronic postoperative pulmonary insufficiency. Thirteen sheep underwent baseline cardiac magnetic resonance imaging, surgical pulmonary valvectomy, and transannular patch repair. One month after transannular patch repair, the hTPV was implanted, followed by serial magnetic resonance imaging and computed tomography imaging at 1, 5, and 8 month(s). hTPV implantation was successful in 11 animals (85%). There were 2 procedural deaths related to ventricular fibrillation. Seven animals survived the entire follow-up protocol, 5 with functioning hTPV devices. Two animals had occlusion of hTPV with aneurysm of main pulmonary artery. A strong decline in pulmonary regurgitant fraction was observed after hTPV implantation (40.5% versus 8.3%; P=0.011). Right ventricular end diastolic volume increased by 49.4% after transannular patch repair (62.3-93.1 mL/m 2 ; P=0.028) but was reversed to baseline values after hTPV implantation (to 65.1 mL/m 2 at 8 months, P=0.045). Both right ventricular ejection fraction and left ventricular ejection fraction were preserved after hTPV implantation. hTPV implantation is feasible, significantly reduces pulmonary regurgitant fraction, facilitates right ventricular volume improvements, and preserves biventricular function in an ovine model of chronic pulmonary insufficiency. This percutaneous strategy could potentially offer an alternative for standard surgical pulmonary valve replacement in dilated right ventricular outflow tracts, permitting lower risk, nonsurgical pulmonary valve replacement in previously prohibitive anatomies. © 2016 American Heart Association, Inc.

  17. Atelocollagen Enhances the Healing of Rotator Cuff Tendon in Rabbit Model.

    PubMed

    Suh, Dong-Sam; Lee, Jun-Keun; Yoo, Ji-Chul; Woo, Sang-Hun; Kim, Ga-Ram; Kim, Ju-Won; Choi, Nam-Yong; Kim, Yongdeok; Song, Hyun-Seok

    2017-07-01

    Failure of rotator cuff healing is a common complication despite the rapid development of surgical repair techniques for the torn rotator cuff. To verify the effect of atelocollagen on tendon-to-bone healing in the rabbit supraspinatus tendon compared with conventional cuff repair. Controlled laboratory study. A tear of the supraspinatus tendon was created and repaired in 46 New Zealand White rabbits. They were then randomly allocated into 2 groups (23 rabbits per group; 15 for histological and 8 for biomechanical test). In the experimental group, patch-type atelocollagen was implanted between bone and tendon during repair; in the control group, the torn tendon was repaired without atelocollagen. Each opposite shoulder served as a sham (tendon was exposed only). Histological evaluation was performed at 4, 8, and 12 weeks. Biomechanical tensile strength was tested 12 weeks after surgery. Histological evaluation scores of the experimental group (4.0 ± 1.0) were significantly superior to those of the control group (7.7 ± 2.7) at 12 weeks ( P = .005). The load to failure was significantly higher in the experimental group (51.4 ± 3.9 N) than in the control group (36.4 ± 5.9 N) ( P = .001). Histological and biomechanical studies demonstrated better results in the experimental group using atelocollagen in a rabbit model of the supraspinatus tendon tear. Atelocollagen patch could be used in the cuff repair site to enhance healing.

  18. Long-term outcome of large artificial patch aortic repair for diffuse stenosis in Williams syndrome.

    PubMed

    Sughimoto, Koichi; Takahara, Yoshiharu; Mogi, Kenji; Sakurai, Manabu; Aoki, Chikashi

    2010-10-01

    There have been only a few reports concerning the long-term results of a surgical procedure using a large artificial patch for patients with Williams syndrome. Twelve years have passed since a patient with William's syndrome underwent a surgery with a patch angioplasty for the diffuse supravalvular aortic stenosis and deformities of the neck branch arteries. The patient had a well-balanced aortic growth without stenotic or aneurysmal changes, which was confirmed during the time of the second surgery when replacing the mitral valve. This technique of using a large patch has proven to be safe for Williams syndrome patients with diffuse supravalvular aortic stenosis in the long term.

  19. Performance of an ablator for Space Shuttle inorbit repair in an arc-plasma airstream

    NASA Technical Reports Server (NTRS)

    Stewart, D. A.; Cuellar, M.; Flowers, O.

    1983-01-01

    An ablator patch material performed well in an arc plasma environment simulating nominal Earth entry conditions for the Space Shuttle. Ablation tests using vacuum molded cones provided data to optimize the formulation of a two part polymer system for application under space conditions. The blunt cones were made using a Teflon mold and a state of the art caulking gun. Char stability of formulations with various amounts of catalyst and diluent were investigated. The char was found to be unstable in formulations with low amounts of catalyst and high amounts of diluent. The best polymer system determined by these tests was evaluated using a half tile patch in a multiple High Temperature Reusable surface Insulation tile model. It was demonstrated that this ablator could be applied in a space environment using a state of the art caulking gun, would maintain the outer mold line of the thermal protection system during entry, and would keep the bond line temperature at the aluminum tile interface below the design limit.

  20. Ceramic Adhesive and Methods for On-Orbit Repair of Re-Entry Vehicles

    NASA Technical Reports Server (NTRS)

    Riedell, James A.; Easler, Timothy E.

    2013-01-01

    This adhesive is capable of repairing damaged leading edge components of reentry vehicles while in space, and is novel with regard to its ability to be applied in the vacuum of space, and in a microgravity environment. Once applied, the adhesive provides thermal and oxidation protection to the substrate (in this case, reinforced carbon/carbon composites, RCCs) during re-entry of a space vehicle. Although there may be many formulations for repair adhesives, at the time of this reporting, this is the first known adhesive capable of an on-orbit repair. The adhesive is an engineered ceramic material composed of a pre-ceramic polymer and refractory powders in the form of a paste or putty that can be applied to a scratched, cracked, or fractured composite surface, covering and protecting the damaged area. The adhesive is then "cured" with a heat cycle, thereby cross-linking the polymer into a hardened material and bonding it to the substrate. During the heat of reentry, the material is converted to a ceramic coating that provides thermal and oxidative stability to the repaired area, thus allowing the vehicle to pass safely from space into the upper atmosphere. Ceramic powders such as SiC, ZrB2 and Y2O3 are combined with allylhydridopolycarbosilane (AHPCS) resin, and are mixed to form a paste adhesive. The material is then applied to the damaged area by brush, spatula, trowel, or other means to fill cracks, gaps, and holes, or used to bond patches onto the damaged area. The material is then cured, in a vacuum, preferably at 250F (approximately equal to 121C) for two hours. The re-entry heating of the vehicle at temperatures in excess of 3,000F (approximately equal to 1,650C) then converts this material into a ceramic coating. This invention has demonstrated advantages in resistance to high temperatures, as was demonstrated in more than 100 arc-jet tests in representative environments at NASA. Extensive testing verified oxidation protection for the repaired substrate (RCC), and confirmed that the microstructure of the resulting repair leads to durability and resistance to melting or flow. Its processability and working life in a vacuum was demonstrated by NASA astronauts in glovebox processing studies, as well as on-orbit in the open space shuttle bay. All of these advantages increase the working life of NASA vehicles, as well as improve safety for any crew on a manned vehicle. The adhesive, trademarked NOAX(TM). or Non-Oxide Adhesive Experimental, flew on all space shuttle missions from Return To Flight (STS-114) until the final flight (STS- 135) as a crack repair material for the leading edges and nose cap of the vehicle. NOAX(TM) was patented under U.S. Patents 7,628,878 and 7,888,277.

  1. In vivo experimental study on laser welded ICG-loaded chitosan patches for vessel repair

    NASA Astrophysics Data System (ADS)

    Rossi, Francesca; Matteini, Paolo; Esposito, Giuseppe; Albanese, Alessio; Puca, Alfredo; Maira, Giulio; Rossi, Giacomo; Pini, Roberto

    2011-03-01

    Laser welding of microvessels provides several advantages over conventional suturing techniques: surgical times reduction, vascular healing process improvement, tissue damage reduction. We present the first application of biopolymeric patches in an in vivo laser assisted procedure for vessel repair. The study was performed in 20 New Zealand rabbits. After anesthesia, a 3-cm segment of the right common carotid artery was exposed and clamped proximally and distally. A linear lesion 3 mm in length was carried out. We used a diode laser emitting at 810 nm and equipped with a 300 μm diameter optical fiber. To close the cut, ICG-loaded chitosan films were prepared: chitosan is characterized by biodegradability, biocompatibility, antimicrobial, haemostatic and wound healing-promoting activity. ICG is an organic chromophore commonly used in the laser welding procedures to mediate the photothermal conversion at the basis of the welding effect. The membranes were used to wrap the whole length of the cut, and then they were welded in the correct position by delivering single laser spots to induce local patch/tissue adhesion. The result is an immediate closure of the wound, with no bleeding at clamps release. The animals were observed during follow-up and sacrificed after 2, 7, 30 and 90 days. All the repaired vessels were patent, no bleeding signs were documented. The carotid samples underwent histological examinations. The advantages of the proposed technique are: simplification of the surgical procedure and shortening of the operative time; good strength of the vessel repair; decreased foreign-body reaction, reduced inflammatory response and improved vascular healing process.

  2. Fetoscopic single-layer repair of open spina bifida using a cellulose patch: preliminary clinical experience.

    PubMed

    Pedreira, Denise A L; Zanon, Nelci; de Sá, Renato A M; Acacio, Gregório L; Ogeda, Edilson; Belem, Teresa M L O U; Chmait, Ramen H; Kontopoulos, Eftichia; Quintero, Ruben A

    2014-11-01

    To report our preliminary clinical experience in the antenatal correction of open spina bifida (OSB) using a fetoscopic approach and a simplified closure technique. Four fetuses with lumbar-sacral defects were operated in utero from 25 to 27 weeks. Surgeries were performed percutaneously under general anesthesia using three trocars and partial carbon dioxide insufflation. After dissection of the neural placode, the surrounding skin was closed over a cellulose patch using a single continuous stitch. Surgical closure was successful in three of the four cases. All successful cases showed improvement of the hindbrain herniation and no neonatal neurosurgical repair was required in two cases. Delivery occurred between 31 and 33 weeks, and no fetal or neonatal deaths occurred. Ventriculoperitoneal shunting was not needed in two out of the 3 successful cases. Our preliminary experience suggests that definitive fetoscopic repair of OSB is feasible using our innovative surgical technique. A phase I trial for the fetoscopic correction of OSB with this technique is currently being conducted.

  3. Iatrogenic Aortic Valve Perforation after Ventricular Septal Defect Repair

    PubMed Central

    Ren, Chonglei; Wang, Mingyan; Wang, Yao; Gao, Changqing

    2017-01-01

    Iatrogenic aortic valve (AV) perforation during non-aortic cardiac operations is a rare complication. The suture-related inadvertent injury to an AV leaflet can produce leaflet perforation with aortic regurgitation after ventricular septal defect repair (VSDR). We report three consecutive patients who had iatrogenic aortic leaflet perforation during VSDR in other hospitals and referred to our hospital for reoperation. In all three cases, the perforated AV leaflets were preserved and repaired by autologous pericardial patch or direct local closure. PMID:29057770

  4. Outcomes of aortopulmonary window repair in children: 33 years of experience.

    PubMed

    Naimo, Phillip S; Yong, Matthew S; d'Udekem, Yves; Brizard, Christian P; Kelly, Andrew; Weintraub, Robert; Konstantinov, Igor E

    2014-11-01

    The purpose of this study was to assess the outcomes of children undergoing repair of aortopulmonary window (APW). We conducted a retrospective review of all children (n=43) who underwent surgical repair of APW between 1980 and 2013. Median age at surgery was 40 days (range, 13 to 125). Simple APW was present in 15 of 43 patients (35%), and 28 of 43 patients (65%) patients had concomitant cardiovascular anomalies. The aorta was repaired by direct suturing in 36 patients (84%) patients and patching in 7 patients (16%). The main pulmonary artery was repaired by direct suturing in 22 patients (51%) patients and by patching in 21 (49%). Cardiopulmonary bypass was used in 42 of the 43 patients (97.7%). Single-staged repair of concomitant cardiovascular anomalies was undertaken in 26 of 28 patients (93%). Only 2 of the 28 patients (7%) underwent repair of interrupted aortic arch before APW repair. Operative mortality was 6.7% (1 of 15 patients) among patients with simple APW and 18% (5 of 28 patients) among patients with concomitant anomalies. Operative weight less than 2.5 kg was associated with mortality on univariable analysis (p=0.02). Median follow-up was 10.1 years (range, 0.17 to 24.2). There were no late deaths. Overall survival was 86% (95% confidence interval: 71.3 to 94.2) at 10 years. Freedom from reoperation was 95.3% (95% confidence interval: 86.2 to 99.9) at 10 years. At last follow-up, all patients were in New York Heart Association functional class I/II. Survival beyond discharge from the hospital is associated with excellent outcomes. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  5. No patch technique for complete atrioventricular canal repair.

    PubMed

    Aramendi, José Ignacio; Rodriguez, Miguel Angel; Luis, Teresa; Voces, Roberto

    2006-08-01

    We describe our initial experience with a new technique, consisting in direct closure of the ventricular septal defect component of the AV canal, by directly attaching the common bridging leaflets to the crest of the ventricular septum with interrupted sutures. After closure of the cleft, the ostium primum defect was closed with a running suture suturing the border of the septum primum to the newly created AV valve annulus. Three patients were operated upon. There was no mortality. Mean ischemic time was 39 min and mean pump time 77 min. All patients remained in sinus rhythm. At follow-up only trivial or mild mitral regurgitation was observed. This new technique permits the repair of complete AV canal without the need for any patch. It is fast, simple and reproducible.

  6. Comparative Analysis of the Biaxial Mechanical Behavior of Carotid Wall Tissue and Biological and Synthetic Materials Used for Carotid Patch Angioplasty

    PubMed Central

    Kamenskiy, Alexey V.; Pipinos, Iraklis I.; MacTaggart, Jason N.; Jaffar Kazmi, Syed A.; Dzenis, Yuris A.

    2011-01-01

    Patch angioplasty is the most common technique used for the performance of carotid endarterectomy. A large number of patching materials are available for use while new materials are being continuously developed. Surprisingly little is known about the mechanical properties of these materials and how these properties compare with those of the carotid artery wall. Mismatch of the mechanical properties can produce mechanical and hemodynamic effects that may compromise the long-term patency of the endarterectomized arterial segment. The aim of this paper was to systematically evaluate and compare the biaxial mechanical behavior of the most commonly used patching materials. We compared PTFE (n = 1), Dacron (n = 2), bovine pericardium (n = 10), autogenous greater saphenous vein (n = 10), and autogenous external jugular vein (n = 9) with the wall of the common carotid artery (n = 18). All patching materials were found to be significantly stiffer than the carotid wall in both the longitudinal and circumferential directions. Synthetic patches demonstrated the most mismatch in stiffness values and vein patches the least mismatch in stiffness values compared to those of the native carotid artery. All biological materials, including the carotid artery, demonstrated substantial nonlinearity, anisotropy, and variability; however, the behavior of biological and biologically-derived patches was both qualitatively and quantitatively different from the behavior of the carotid wall. The majority of carotid arteries tested were stiffer in the circumferential direction, while the opposite anisotropy was observed for all types of vein patches and bovine pericardium. The rates of increase in the nonlinear stiffness over the physiological stress range were also different for the carotid and patching materials. Several carotid wall samples exhibited reverse anisotropy compared to the average behavior of the carotid tissue. A similar characteristic was observed for two of 19 vein patches. The obtained results quantify, for the first time, significant mechanical dissimilarity of the currently available patching materials and the carotid artery. The results can be used as guidance for designing more efficient patches with mechanical properties resembling those of the carotid wall. The presented systematic comparative mechanical analysis of the existing patching materials provides valuable information for patch selection in the daily practice of carotid surgery and can be used in future clinical studies comparing the efficacy of different patches in the performance of carotid endarterectomy. PMID:22168740

  7. Conjunctival inclusion cyst following repair of tube erosion in a child with aphakic glaucoma, leading to endophthalmitis.

    PubMed

    Roy, Avik Kumar; Senthil, Sirisha

    2015-01-01

    Glaucoma in aphakia is a major long term complication following congenital cataract surgery. Implantation of glaucoma drainage device provides an effective approach to manage refractory paediatric glaucoma. However implant surgery in young individuals is not free of complications. The prompt detection and management of tube erosion is of utmost importance to prevent devastating sequel of endophthalmitis. Implantation cyst following repair of tube erosion has not been reported so far. This case illustrates the rare occurrence of inclusion cyst following repair of tube erosion, the possible causes and its consequences. A 2-year-old child with aphakia developed intractable glaucoma. Following a failed glaucoma filtering surgery he underwent sequential Ahmed Glaucoma Valve implantation in both the eyes. Six weeks following right eye surgery, the child presented with conjunctival erosion overlying the tube, which was treated with scleral patch graft and conjunctival advancement. One month after the repair of tube erosion, the child presented with implantation cyst under the scleral patch graft, which was treated by drainage with a 29G needle. The child presented with endophthalmitis of his right eye following an episode of bilateral conjunctivitis. This was managed by an emergency pars plana vitrectomy, intraocular antibiotics and tube excision. At the last follow up visit, the IOP was 20 mmHg with 2 topical antiglaucoma medications in the right eye following a trans scleral photocoagulation. Lifelong careful follow-up of paediatric eyes with implant surgery is mandatory to look for complication such as tube erosion. It is important to place additional sutures to secure the patch graft during implantation of glaucoma drainage devices in children to prevent graft displacement and consequent tube erosion. During repair of tube erosion, it is crucial to remove all the conjunctival epithelium around the tube, thus not to incorporate epithelial tissue within the surgical wound.

  8. Repair of tetralogy of Fallot associated with atrioventricular septal defect.

    PubMed

    Tláskal, T; Hucín, B; Kostelka, M; Chaloupecký, V; Marek, J; Tax, P; Janouàek, J; Kuèera, V; Hruda, J; Reich, O; Skovránek, J

    1998-01-01

    Tetralogy of Fallot, when associated with atrioventricular septal defect permitting shunting at ventricular level, represents a complex cyanotic congenital malformation. Experience with surgical repair is limited, and results vary considerably. Between 1984 and 1996, we repaired 14 consecutive patients with this combination seen in our center. Their ages ranged from 8 months to 21 years (median 7.4 years). Six (42.9%) had Down's syndrome. In eight patients the correct diagnosis was made using echocardiography alone. In the remaining six patients, who had previously-constructed arterial shunts and/or suspected pulmonary arterial stenosis, catheterization and angiocardiography were also performed. The repair consisted of double patch closure of the septal defect, reconstruction of two atrioventricular orifices, and relief of pulmonary stenosis at all levels. In five patients with a hypoplastic pulmonary trunk, a monocusp transannular patch (four patients) or an allograft (one patient) was used for restoration of continuity from the right ventricle to the pulmonary arteries. Patch enlargement of one or both pulmonary arteries was necessary in five patients. One patient (7.1%) died early, and another late. The twelve surviving (85.8%) patients have been followed for 1.2-12.5 years after surgery (median 4.9 years, mean 5.9+/-3.9 years). During the follow-up, reoperation was necessary for repair of residual ventricular septal defect and pulmonary regurgitation in two patients, and closure of an atrial septal defect and alteration to left atrioventricular valvar regurgitation in one patient. Seven patients are in class I of the New York Heart Association, four in class II, and one in class III. Tetralogy of Fallot associated with atrioventricular septal defect can be corrected with low mortality and good long-term results. Residual lesions, however, have a tendency to progress, especially when seen in combination. After surgery, all patients need long-term close follow-up.

  9. Long-term results of pulmonary valve annular enlargement with valve repair in tetralogy of Fallot.

    PubMed

    Kim, Hyungtae; Sung, Si Chan; Choi, Kwang Ho; Lee, Hyoung Doo; Kim, Geena; Ko, Hoon; Lee, Young Seok

    2018-06-01

    We adopted an operative technique of pulmonary valve (PV) annular enlargement with valve repair in tetralogy of Fallot (TOF) correction to reduce postoperative pulmonary regurgitation (PR) 16 years ago. Here, we have evaluated the long-term results. Between April 2000 and August 2005, 43 patients (26 men) with tetralogy of Fallot with pulmonary stenosis underwent PV annular enlargement with valve repair. The median age and body weight at the time of surgery were 14 months and 10.2 kg, respectively. There was no operative mortality. Mean postoperative PR grade at discharge was 0.93 ± 0.40 (none or trivial in 10 patients, mild in 27 patients, mild to moderate in 5 patients and moderate in 1 patient), and the mean postoperative pressure gradient across PV was 13.0 ± 10.9 mmHg. The mean follow-up duration was 131.9 ± 42.9 months. During follow-up, 1 reoperation was performed for residual ventricular septal defect. The mean PR grade at the last follow-up echocardiography was 1.59 ± 0.60 (mild in 17 patients, mild to moderate in 8 patients, moderate in 14 patients, moderate to severe in 1 patient and severe in 3 patients), and the mean pressure gradient was 22.7 ± 9.9 mmHg. We have compared the incidence of moderate or more PR with the incidence of patients who underwent simple transannular patch enlargement through propensity score matching. The PV repair group had a lower incidence of moderate or more PR compared with the simple transannular patch group (40% vs 68%, P = 0.04). PV annular enlargement with valve repair has reasonable long-term results and yields a lower long-term incidence of significant PR compared with the simple transannular patch enlargement technique.

  10. New Technologies for Surgery of the Congenital Cardiac Defect

    PubMed Central

    Kalfa, David; Bacha, Emile

    2013-01-01

    The surgical repair of complex congenital heart defects frequently requires additional tissue in various forms, such as patches, conduits, and valves. These devices often require replacement over a patient’s lifetime because of degeneration, calcification, or lack of growth. The main new technologies in congenital cardiac surgery aim at, on the one hand, avoiding such reoperations and, on the other hand, improving long-term outcomes of devices used to repair or replace diseased structural malformations. These technologies are: 1) new patches: CorMatrix® patches made of decellularized porcine small intestinal submucosa extracellular matrix; 2) new devices: the Melody® valve (for percutaneous pulmonary valve implantation) and tissue-engineered valved conduits (either decellularized scaffolds or polymeric scaffolds); and 3) new emerging fields, such as antenatal corrective cardiac surgery or robotically assisted congenital cardiac surgical procedures. These new technologies for structural malformation surgery are still in their infancy but certainly present great promise for the future. But the translation of these emerging technologies to routine health care and public health policy will also largely depend on economic considerations, value judgments, and political factors. PMID:23908869

  11. Comparison of a novel bone-tendon allograft with a human dermis-derived patch for repair of chronic large rotator cuff tears using a canine model.

    PubMed

    Smith, Matthew J; Cook, James L; Kuroki, Keiichi; Jayabalan, Prakash S; Cook, Cristi R; Pfeiffer, Ferris M; Waters, Nicole P

    2012-02-01

    This study tested a bone-tendon allograft versus human dermis patch for reconstructing chronic rotator cuff repair by use of a canine model. Mature research dogs (N = 15) were used. Radiopaque wire was placed in the infraspinatus tendon (IST) before its transection. Three weeks later, radiographs showed IST retraction. Each dog then underwent 1 IST treatment: debridement (D), direct repair of IST to bone with a suture bridge and human dermis patch augmentation (GJ), or bone-tendon allograft (BT) reconstruction. Outcome measures included lameness grading, radiographs, and ultrasonographic assessment. Dogs were killed 6 months after surgery and both shoulders assessed biomechanically and histologically. BT dogs were significantly (P = .01) less lame than the other groups. BT dogs had superior bone-tendon, tendon, and tendon-muscle integrity compared with D and GJ dogs. Biomechanical testing showed that the D group had significantly (P = .05) more elongation than the other groups whereas BT had stiffness and elongation characteristics that most closely matched normal controls. Radiographically, D and GJ dogs showed significantly more retraction than BT dogs (P = .003 and P = .045, respectively) Histologically, GJ dogs had lymphoplasmacytic infiltrates, tendon degeneration and hypocellularity, and poor tendon-bone integration. BT dogs showed complete incorporation of allograft bone into host bone, normal bone-tendon junctions, and well-integrated allograft tendon. The bone-tendon allograft technique re-establishes a functional IST bone-tendon-muscle unit and maintains integrity of repair in this model. Clinical trials using this bone-tendon allograft technique are warranted. Copyright © 2012 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  12. Aortic valve insufficiency in the teenager and young adult: the role of prosthetic valve replacement.

    PubMed

    Bradley, Scott M

    2013-10-01

    The contents of this article were presented in the session "Aortic insufficiency in the teenager" at the congenital parallel symposium of the 2013 Society of Thoracic Surgeons (STS) annual meeting. The accompanying articles detail the approaches of aortic valve repair and the Ross procedure.(1,2) The current article focuses on prosthetic valve replacement. For many young patients requiring aortic valve surgery, either aortic valve repair or a Ross procedure provides a good option. The advantages include avoidance of anticoagulation and potential for growth. In other patients, a prosthetic valve is an appropriate alternative. This article discusses the current state of knowledge regarding mechanical and bioprosthetic valve prostheses and their specific advantages relative to valve repair or a Ross procedure. In current practice, young patients requiring aortic valve surgery frequently undergo valve replacement with a prosthetic valve. In STS adult cardiac database, among patients ≤30 years of age undergoing aortic valve surgery, 34% had placement of a mechanical valve, 51% had placement of a bioprosthetic valve, 9% had aortic valve repair, and 2% had a Ross procedure. In the STS congenital database, among patients 12 to 30 years of age undergoing aortic valve surgery, 21% had placement of a mechanical valve, 18% had placement of a bioprosthetic valve, 30% had aortic valve repair, and 24% had a Ross procedure. In the future, the balance among these options may be altered by design improvements in prosthetic valves, alternatives to warfarin, the development of new patch materials for valve repair, and techniques to avoid Ross autograft failure.

  13. [Inguinal hernia repair: results of randomized clinical trials and meta-analyses].

    PubMed

    Slim, K; Vons, C

    2008-01-01

    This evidence-based review of the literature aims to answer two questions regarding inguinal hernia repair: 1. should a prosthetic patch be used routinely? 2. Which approach is better - laparoscopic or open surgery? After a comprehensive search of electronic databases we retained only meta-analyses (n=14) and/or randomised clinical trials (n=4). Review of this literature suggests with a good level of evidence that prosthetic hernia repair is the gold standard; the laparoscopic approach has very few proven benefits and may involve more serious complications when performed outside expert centers. The role of laparoscopy for the repair of bilateral or recurrent hernias needs better evaluation.

  14. Multi-Physics MRI-Based Two-Layer Fluid-Structure Interaction Anisotropic Models of Human Right and Left Ventricles with Different Patch Materials: Cardiac Function Assessment and Mechanical Stress Analysis

    PubMed Central

    Tang, Dalin; Yang, Chun; Geva, Tal; Gaudette, Glenn; del Nido, Pedro J.

    2011-01-01

    Multi-physics right and left ventricle (RV/LV) fluid-structure interaction (FSI) models were introduced to perform mechanical stress analysis and evaluate the effect of patch materials on RV function. The FSI models included three different patch materials (Dacron scaffold, treated pericardium, and contracting myocardium), two-layer construction, fiber orientation, and active anisotropic material properties. The models were constructed based on cardiac magnetic resonance (CMR) images acquired from a patient with severe RV dilatation and solved by ADINA. Our results indicate that the patch model with contracting myocardium leads to decreased stress level in the patch area, improved RV function and patch area contractility. PMID:21765559

  15. Results of tests of K5NA and a revised formulation of EPDM/cork patch material in MSFC Hot Gas Facility

    NASA Technical Reports Server (NTRS)

    Dean, W. G.

    1982-01-01

    During prelaunch procedures at Kennedy Space Center some of the EPDM Thermal Protection System material was damaged on the Solid Rocket Booster stiffener stubs. The preferred solution was to patch the damaged areas with a cork-filled epoxy patching compound. Before this was done, however, it was requested that this patching technique be checked out by testing it in the MSFC Hot Gas Facility. Two tests were run in the HFG in 1980. The results showed the patch material to be adequate. Since that time, the formulation of the cork-filled epoxy material has been changed. It became necessary to retest this concept to be sure that the new material is as good as or better than the original material. In addition to the revised formulation material, tests were also made using K5NA as the patch material. The objectives of the tests reported herein were to: (1) compare the thermal performance of the original and the new cork-filled epoxy formulations, and (2) compare the K5NA closeout material to these epoxy materials. Material specifications are also discussed.

  16. On structural health monitoring of aircraft adhesively bonded repairs

    NASA Astrophysics Data System (ADS)

    Pavlopoulou, Sofia

    The recent interest in life extension of ageing aircraft and the need to address the repair challenges in the new age composite ones, led to the investigation of new repair methodologies such as adhesively bonded repair patches. The present thesis focuses on structural health monitoring aspects of the repairs, evaluating their performance with guided ultrasonic waves aiming to develop a monitoring strategy which would eliminate unscheduled maintenance and unnecessary inspection costs. To address the complex nature of the wave propagation phenomena, a finite element based model identified the existing challenges by exploring the interaction of the excitation waves with different levels of damage. The damage sensitivity of the first anti-symmetric mode was numerically investigated. An external bonded patch and a scarf repair, were further tested in static and dynamic loadings, and their performance was monitored with Lamb waves, excited by surface-bonded piezoelectric transducers.. The response was processed by means of advanced pattern recognition and data dimension reduction techniques such as novelty detection and principal component analysis. An optimisation of these tools enabled an accurate damage detection under complex conditions. The phenomena of mode isolation and precise arrival time determination under a noisy environment and the problem of inadequate training data were investigated and solved through appropriate transducer arrangements and advanced signal processing respectively. The applicability of the established techniques was demonstrated on an aluminium repaired helicopter tail stabilizer. Each case study utilised alternative non-destructive techniques for validation such as 3D digital image correlation, X-ray radiography and thermography. Finally a feature selection strategy was developed through the analysis of the instantaneous properties of guided waves for damage detection purposes..

  17. Earlier Pulmonary Valve Replacement in Down Syndrome Patients Following Tetralogy of Fallot Repair.

    PubMed

    Sullivan, Rachel T; Frommelt, Peter C; Hill, Garick D

    2017-08-01

    The association between Down syndrome and pulmonary hypertension could contribute to more severe pulmonary regurgitation after tetralogy of Fallot repair and possibly earlier pulmonary valve replacement. We compared cardiac magnetic resonance measures of pulmonary regurgitation and right ventricular dilation as well as timing of pulmonary valve replacement between those with and without Down syndrome after tetralogy of Fallot repair. Review of our surgical database from 2000 to 2015 identified patients with tetralogy of Fallot with pulmonary stenosis. Those with Down syndrome were compared to those without. The primary outcome of interest was time from repair to pulmonary valve replacement. Secondary outcomes included pulmonary regurgitation and indexed right ventricular volume on cardiac magnetic resonance imaging. The cohort of 284 patients included 35 (12%) with Down syndrome. Transannular patch repair was performed in 210 (74%). Down syndrome showed greater degree of pulmonary regurgitation (55 ± 14 vs. 37 ± 16%, p = 0.01) without a significantly greater rate of right ventricular dilation (p = 0.09). In multivariable analysis, Down syndrome (HR 2.3, 95% CI 1.2-4.5, p = 0.02) and transannular patch repair (HR 5.5, 95% CI 1.7-17.6, p = 0.004) were significant risk factors for valve replacement. Those with Down syndrome had significantly lower freedom from valve replacement (p = 0.03). Down syndrome is associated with an increased degree of pulmonary regurgitation and earlier pulmonary valve replacement after tetralogy of Fallot repair. These patients require earlier assessment by cardiac magnetic resonance imaging to determine timing of pulmonary valve replacement and evaluation for and treatment of preventable causes of pulmonary hypertension.

  18. Development of a self-stressing NiTiNb shape memory alloy (SMA)/fiber reinforced polymer (FRP) patch

    NASA Astrophysics Data System (ADS)

    El-Tahan, M.; Dawood, M.; Song, G.

    2015-06-01

    The objective of this research is to develop a self-stressing patch using a combination of shape memory alloys (SMAs) and fiber reinforced polymer (FRP) composites. Prestressed carbon FRP patches are emerging as a promising alternative to traditional methods to repair cracked steel structures and civil infrastructure. However, prestressing these patches typically requires heavy and complex fixtures, which is impractical in many applications. This paper presents a new approach in which the prestressing force is applied by restraining the shape memory effect of NiTiNb SMA wires. The wires are subsequently embedded in an FRP overlay patch. This method overcomes the practical challenges associated with conventional prestressing. This paper presents the conceptual development of the self-stressing patch with the support of experimental observations. The bond between the SMA wires and the FRP is evaluated using pull-out tests. The paper concludes with an experimental study that evaluates the patch response during activation subsequent monotonic tensile loading. The results demonstrate that the self-stressing patch with NiTiNb SMA is capable of generating a significant prestressing force with minimal tool and labor requirements.

  19. Gene manipulated peritoneal cell patch repairs infarcted myocardium

    PubMed Central

    Huang, Wei; Zhang, Dongsheng; Millard, Ronald W.; Wang, Tao; Zhao, Tiemin; Fan, Guo-Chang; Ashraf, Atif; Xu, Meifeng; Ashraf, Muhammad; Wang, Yigang

    2010-01-01

    A gene manipulated cell patch using a homologous peritoneum substrate was developed and applied after myocardial infarction to repair scarred myocardium. We genetically engineered male rat mesenchymal stem cells (MSC) using adenoviral transduction to over-express CXCR4/green fluorescent protein (GFP) (MSCCXCR4) or MSCNull or siRNA targeting CXCR4 (MSCsiRNA). Gene expression was studied by real-time quantitative PCR (qPCR) and enzyme-linked immunosorbent assay (ELISA). Cells were cultured on excised peritoneum for 9 days. Two weeks after left anterior descending (LAD) coronary artery ligation in female hearts, the peritoneum patch was applied over the scarred myocardium, cell side down. Efficacy of engraftment was determined by presence of GFP positive cells. One month after cell implantation, echocardiography was performed and hearts were harvested for histological analysis. Left ventricle (LV) fibrosis, LV anterior wall thickness (AWT) and blood vessel density at the margins of the graft were measured. There was significant up-regulation of the chemokines in the MSCCXCR4 group cultured under normoxic conditions when compared to the MSCNull group and a further increase was observed after exposure to hypoxia. One month after cell transplantation with the peritoneum patch, substantial numbers of GFP-positive cells were observed in and around the infarcted myocardium in MSCCXCR4 group. LV AWT, LV fibrosis and LV function were significantly improved in the MSCCXCR4 group as compared to these same variables in the MSCNull control. These salutary effects were absent in MSCsiRNA group. The gene manipulated MSC-seeded peritoneum patch promotes tissue nutrition (angiogenesis), reduces myocardial remodeling, and enhances heart function after myocardial infarction. PMID:19913551

  20. The Fanconi Anemia DNA Repair Pathway Is Regulated by an Interaction between Ubiquitin and the E2-like Fold Domain of FANCL*

    PubMed Central

    Miles, Jennifer A.; Frost, Mark G.; Carroll, Eilis; Rowe, Michelle L.; Howard, Mark J.; Sidhu, Ateesh; Chaugule, Viduth K.; Alpi, Arno F.; Walden, Helen

    2015-01-01

    The Fanconi Anemia (FA) DNA repair pathway is essential for the recognition and repair of DNA interstrand crosslinks (ICL). Inefficient repair of these ICL can lead to leukemia and bone marrow failure. A critical step in the pathway is the monoubiquitination of FANCD2 by the RING E3 ligase FANCL. FANCL comprises 3 domains, a RING domain that interacts with E2 conjugating enzymes, a central domain required for substrate interaction, and an N-terminal E2-like fold (ELF) domain. The ELF domain is found in all FANCL homologues, yet the function of the domain remains unknown. We report here that the ELF domain of FANCL is required to mediate a non-covalent interaction between FANCL and ubiquitin. The interaction involves the canonical Ile44 patch on ubiquitin, and a functionally conserved patch on FANCL. We show that the interaction is not necessary for the recognition of the core complex, it does not enhance the interaction between FANCL and Ube2T, and is not required for FANCD2 monoubiquitination in vitro. However, we demonstrate that the ELF domain is required to promote efficient DNA damage-induced FANCD2 monoubiquitination in vertebrate cells, suggesting an important function of ubiquitin binding by FANCL in vivo. PMID:26149689

  1. Damage Tolerant Repair Techniques for Pressurized Aircraft Fuselages

    DTIC Science & Technology

    1994-01-01

    2 if20 20 offset 50, fatigue GST, GLARE 2 if20 20 static, no fatigue *Unidirectional SP500 carbon/epoxy tape . "* Fatigue load did not initiate a crack...Et value, so this is a reasonable assumption. It further implies zero crack opening under the patch. The Erdogan solution [51 for two collinear...Cr Figure 6. 11. Idealization of patched crack as unfailed ligament between two collinear cracks (after [5, 6)). The Erdogan solution leads to the AK

  2. Graft Utilization in the Augmentation of Large-to-Massive Rotator Cuff Repairs: A Systematic Review.

    PubMed

    Ferguson, Devin P; Lewington, Matthew R; Smith, T Duncan; Wong, Ivan H

    2016-11-01

    Current treatment options for symptomatic large-to-massive rotator cuff tears can reduce pain, but failure rates remain high. Surgeons have incorporated synthetic and biologic grafts to augment these repairs, with promising results. Multiple reviews exist that summarize these products; however, no systematic review has investigated the grafts' ability to maintain structural integrity after augmentation of large-to-massive rotator cuff repairs. To systematically review and evaluate the effectiveness of grafts in the augmentation of large-to-massive rotator cuff repairs. Systematic review. A comprehensive search of 4 reputable databases was completed. Inclusion criteria were (1) large-to-massive rotator cuff tear, (2) graft augmentation of primary repairs ± primary repair control group, and (3) minimum clinical and radiologic follow-up of 12 months. Two reviewers screened the titles, abstracts, and full articles and extracted the data from eligible studies. Results were summarized into evidence tables stratified by graft origin and level of evidence. Ten studies fit the inclusion criteria. Allograft augmentation was functionally and structurally superior to primary repair controls, with intact repairs in 85% versus 40% of patients (P < .01). This was supported by observational study data. Xenograft augmentation failed to demonstrate superiority to primary repair controls, with worse structural healing rates (27% vs 60%; P =.11). Both comparative studies supported this finding. There have also been many reports of inflammatory reactions with xenograft use. Polypropylene patches are associated with improved structural (83% vs 59% and 49%; P < .01) and functional outcomes when compared with controls and xenograft augmentation; however, randomized data are lacking. Augmentation of large-to-massive rotator cuff repairs with human dermal allografts is associated with superior functional and structural outcome when compared with conventional primary repair. Xenograft augmentation failed to demonstrate a statistically significant difference and may be associated with worse rerupture rates and occasional severe inflammatory reactions. Polypropylene patches have initial promising results. Research in this field is limited; future researchers should continue to develop prospective, randomized controlled trials to establish clear recommendations. © 2016 The Author(s).

  3. Fatigue behavior of a thermally-activated NiTiNb SMA-FRP patch

    NASA Astrophysics Data System (ADS)

    El-Tahan, M.; Dawood, M.

    2016-01-01

    This paper presents the details of an experimental study that was conducted to characterize the fatigue behavior of a thermally-activated shape memory alloy (SMA)/carbon fiber reinforced polymer (CFRP) patch that can be used to repair cracked steel members. A total of 14 thermally-activated patches were fabricated and tested to evaluate the stability of the prestress under fatigue loading. The parameters considered in this study are the prestress level in the nickel-titanium-niobium SMA wires and the applied force range. An empirical model to predict the degradation of the prestress is also presented. The results indicate that patches for which the maximum applied loads in a fatigue cycle did not cause debonding of the SMA wires from the CFRP sustained two million loading cycles with less than 20% degradation of the prestress.

  4. A modern era comparison of right versus left sided congenital diaphragmatic hernia outcomes.

    PubMed

    Collin, Michael; Trinder, Sarah; Minutillo, Corrado; Rao, Shripada; Dickinson, Jan; Samnakay, Naeem

    2016-09-01

    This study aims to retrospectively review outcomes, including neurodevelopmental outcomes, of neonatal right sided congenital diaphragmatic hernias (RCDH) compared with left sided congenital diaphragmatic hernias (L-CDH) treated surgically at our institute. A retrospective review was undertaken of all cases of congenital diaphragmatic hernia (CDH) treated at Princess Margaret Hospital for Children (PMH), Perth, born between 1st January 2002 and 1st August 2012. The outcomes of R-CDH cases were compared with L-CDH cases. We examined duration of ventilatory support, use of patch versus primary closure, the CDH recurrence rates, the number of reoperations and neurodevelopmental follow-up at one year of age. Forty-nine cases of CDH were operated on at PMH during the 10-year period. Of these, ten cases were R-CDH with 39 L-CDH cases. Of 49 cases, 34 were diagnosed antenatally, 5 R-CDH versus 29 L-CDH. Only 8/39 cases of L-CDH required patch repair for larger defects, while 5/10 R-CDH required patch repair. Postoperative mortality was 6/49 (1/10 right sided versus 5/39 left sided). Recurrence was observed in 5/10 R-CDH versus 6/39 L-CDH with p=0.03. Thirty-three of 43 surviving patients received one-year follow-up with Griffiths general quotient (GQ) assessment demonstrating a median score of 98 for L-CDH (IQR 86 to 104.25) and 91 for R-CDH (IQR 76.5 to 93). R-CDH required patch repair more commonly than L-CDH because of larger defect size or complete agenesis. The rate of recurrent herniation was the only morbidity significantly higher in the R-CDH group. Survivors of R-CDH did not have a significant difference in neurodevelopmental outcome compared to L-CDH cases, with both groups exhibiting normal median GQ scores at one year of age. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.

  5. Neonatal right ventricle to pulmonary connection as a palliative procedure for pulmonary atresia with ventricular septal defect or severe tetralogy of Fallot.

    PubMed

    Gerelli, Sébastien; van Steenberghe, Mathieu; Murtuza, Bari; Bojan, Mirela; Harding, Ekoué Diana; Bonnet, Damien; Vouhé, Pascal R; Raisky, Olivier

    2014-02-01

    Right ventricle to pulmonary artery connection (RVPA connection) without prosthetic material has been our ideal strategy to palliate pulmonary atresia with ventricular septal defect (VSD) or severe tetralogy of Fallot for the last decade. We speculate that RVPA connection ensures adequate postoperative haemodynamics for symptomatic neonates and promotes pulmonary artery rehabilitation. The present study was undertaken to assess the outcome of this strategy. Between 2000 and 2010, among 107 patients who benefited from an RVPA connection, 57 were neonates. Forty-eight of these underwent autologous tissue reconstruction, 5 using left atrial appendage. Median weight was 2.9 kg (range 1.8-4.4). Median Nakata index was 100 mm2/m2 (range 17-185 mm2/m2); 12% had major aortopulmonary collaterals. All patients were reviewed retrospectively. End-points were death or complete repair; reintervention for restrictive pulmonary blood flow was considered as failure. At follow-up, we evaluated reintervention after complete repair, and quality of life. There were 2 early deaths (RV hypoplasia and RV failure) and 3 late sudden deaths (range 3-6 months). Pulmonary blood flow required to be increased in 8 patients: 4 underwent shunt after a median delay of 1 month; RVPA connection enlargement was needed in 3; 1 patient had percutaneous angioplasty. Finally, 47 patients (81%) had a complete repair, of which 70% were performed without prosthetic material at a median age of 7 months (range 2-53), with a median Nakata index of 221 mm2/m2 (range 102-891). One patient died early and 1 was a failure with opening of the VSD after intracardiac repair. At last follow-up, 4 patients were still awaiting repair, with 1 late death and 5 who had required reintervention after intracardiac repair; there were 3 conduit replacements and 2 balloon dilatation patch enlargements. The neonatal RVPA connection approach (i) provides an acceptable survival rate with a satisfactory haemodynamic adaptation, (ii) facilitates rehabilitation of PAs and (iii) avoids the use of prosthetic graft at correction.

  6. Finite element modeling to determine thermal residual strain distribution of bonded composite repairs for structural health monitoring design

    NASA Astrophysics Data System (ADS)

    Baker, Wayne; Jones, Rhys; Davis, Claire; Galea, Stephen C.

    2002-11-01

    The economic implication of fleet upgrades, particularly in Australia with military aircraft such as the F-111 and F/A-18, has led to an increasing reliance on composite repair technology to address fatigue and corrosion-affected aircraft components. The increasing use of such repairs has led to a research effort to develop various in-situ health monitoring systems that may be incorporated with a repair. This paper reports on the development of a theoretical methodology that uses finite element analysis (FEA) to model the strain profiles which optical sensors, on or within the patch, will be exposed to under various operational scenarios, including load and disbond. Numerical techniques are then used to predict the fibre Bragg grating (FBG) reflections which occur with these strain profiles. The quality of these reflection are a key consideration when designing FBG based structural health monitoring (SHM) systems. This information can be used to optimise the location of both surface mounted, and embedded sensors, and determine feasibility of SHM system design. Research was conducted into the thermal residual strain (TRS) within the patch. A finite element study revealed the presence of significant thermal residual strain gradients along the surface of the tapered region of the patch. As Bragg gratings are particularly sensitive to strain gradients, (producing a result similar to a chirped grating) the strain gradient on the composite at potential sensor locations both under load, and in the event of disbond was considered. A sufficiently high gradient leads to an altered Bragg reflection. These spurious reflections need to be considered, and theoretically obtained reflections can provide information to allow for load scenarios where the Bragg shift is not a smooth, well defined peak. It can also be shown that embedded fibres offer a higher average thermal residual strain reading, while being subject to a much lower strain gradient. This particularly favors the optical disbond detection system that is being developed. While certification concerns exist with embedding sensors in repairs, this study shows that embedded optical fibre sensors may provide for a health monitoring system with enhanced reliability and sensitivity.

  7. The evaluation of pavement patching materials in Oregon : final report.

    DOT National Transportation Integrated Search

    1980-11-01

    This report describes the installation and evaluation of trial pavement patching materials in Oregon. The patches were placed in Portland cement concrete and bituminous concrete pavements and evaluated for periods ranging from four to twelve months. ...

  8. Plating Patches On Heat-Exchanger Jackets

    NASA Technical Reports Server (NTRS)

    Loureiro, Henry; Kubik, Frank

    1989-01-01

    Permanent repairs made without welding. Technique used to repair nickel-alloy nozzle jacket of Space Shuttle main engine. Applicable to other metal heat-exchanger jackets with similar configurations. Does not require welding, brazing, soldering, or other operations involving high temperatures and consequent damage to surrounding areas. Portion of jacket around damaged area removed by grinding and polishing out to edges adjacent to tube/jacket braze bonds. Spaces between tubes filled with wax preventing contamination of spaces during subsequent plating.

  9. The Fanconi Anemia DNA Repair Pathway Is Regulated by an Interaction between Ubiquitin and the E2-like Fold Domain of FANCL.

    PubMed

    Miles, Jennifer A; Frost, Mark G; Carroll, Eilis; Rowe, Michelle L; Howard, Mark J; Sidhu, Ateesh; Chaugule, Viduth K; Alpi, Arno F; Walden, Helen

    2015-08-21

    The Fanconi Anemia (FA) DNA repair pathway is essential for the recognition and repair of DNA interstrand crosslinks (ICL). Inefficient repair of these ICL can lead to leukemia and bone marrow failure. A critical step in the pathway is the monoubiquitination of FANCD2 by the RING E3 ligase FANCL. FANCL comprises 3 domains, a RING domain that interacts with E2 conjugating enzymes, a central domain required for substrate interaction, and an N-terminal E2-like fold (ELF) domain. The ELF domain is found in all FANCL homologues, yet the function of the domain remains unknown. We report here that the ELF domain of FANCL is required to mediate a non-covalent interaction between FANCL and ubiquitin. The interaction involves the canonical Ile44 patch on ubiquitin, and a functionally conserved patch on FANCL. We show that the interaction is not necessary for the recognition of the core complex, it does not enhance the interaction between FANCL and Ube2T, and is not required for FANCD2 monoubiquitination in vitro. However, we demonstrate that the ELF domain is required to promote efficient DNA damage-induced FANCD2 monoubiquitination in vertebrate cells, suggesting an important function of ubiquitin binding by FANCL in vivo. © 2015 by The American Society for Biochemistry and Molecular Biology, Inc.

  10. Oral buccal mucous membrane allograft with a corneal lamellar graft for the repair of Boston type 1 keratoprosthesis stromal melts.

    PubMed

    Ziai, Setareh; Rootman, David S; Slomovic, Allan R; Chan, Clara C

    2013-11-01

    To describe a surgical technique to repair Boston type 1 keratoprosthesis (KPro)-related corneal melts. Technique description and review of 3 representative cases. After harvesting the buccal mucosa from the patient's inner lower lip, the exposed area of the KPro back plate is prepared for repair by adequate exposure and removal of necrotic tissue. The area is then covered with a lamellar patch of cornea secured in place with interrupted 10-0 nylon sutures, followed by a thin layer of buccal mucosa secured in place with interrupted 8-0 vicryl sutures. This technique provides surgeons with a method to repair KPro-related corneal melts when there is a conjunctival deficiency.

  11. Flexible shape-memory scaffold for minimally invasive delivery of functional tissues

    NASA Astrophysics Data System (ADS)

    Montgomery, Miles; Ahadian, Samad; Davenport Huyer, Locke; Lo Rito, Mauro; Civitarese, Robert A.; Vanderlaan, Rachel D.; Wu, Jun; Reis, Lewis A.; Momen, Abdul; Akbari, Saeed; Pahnke, Aric; Li, Ren-Ke; Caldarone, Christopher A.; Radisic, Milica

    2017-10-01

    Despite great progress in engineering functional tissues for organ repair, including the heart, an invasive surgical approach is still required for their implantation. Here, we designed an elastic and microfabricated scaffold using a biodegradable polymer (poly(octamethylene maleate (anhydride) citrate)) for functional tissue delivery via injection. The scaffold’s shape memory was due to the microfabricated lattice design. Scaffolds and cardiac patches (1 cm × 1 cm) were delivered through an orifice as small as 1 mm, recovering their initial shape following injection without affecting cardiomyocyte viability and function. In a subcutaneous syngeneic rat model, injection of cardiac patches was equivalent to open surgery when comparing vascularization, macrophage recruitment and cell survival. The patches significantly improved cardiac function following myocardial infarction in a rat, compared with the untreated controls. Successful minimally invasive delivery of human cell-derived patches to the epicardium, aorta and liver in a large-animal (porcine) model was achieved.

  12. Repair of Inaccessible Ventral Dural Defect in Thoracic Spine: Double Layered Duraplasty

    PubMed Central

    Lee, Dong-Hyun; Park, Jeong-Ill; Park, Ki-Su; Cho, Dae-Chul; Sung, Joo-Kyung

    2016-01-01

    We propose a double layered (intradural and epidural patch) duraplasty that utilizes Lyoplant and Duraseal. We examined a 47-year-old woman after decompression for thoracic ossification of posterior longitudinal ligament was performed in another hospital. On postoperative day 7, she complained of weakness in both legs. Postoperative magnetic resonance imaging (MRI) showed cerebrospinal fluid (CSF) collection with cord compression. In the operative field, we found 2 large dural defects on the ventral dura mater. We performed a conventional fat graft with fibrin glue. However, the patient exhibited neurologic deterioration, and a postoperative MRI again showed CSF collection. We performed dorsal midline durotomy and inserted a intradural and epidural Lyoplant patch. She immediately experienced diminishing back pain postoperatively. Her visual analog scale and motor power improved markedly. Postoperative MRIs performed at 2 and 16 months showed no spinal cord compression or CSF leakage to the epidural space. We describe a new technique for double layered duraplasty. Although we do not recommend this technique for all dural repairs, double-layered duraplasty may be useful for repairing large inaccessible dural tears in cases of persistent CSF leakage refractory to conventional management. PMID:27437022

  13. Acrylate-induced allergic contact dermatitis in a car windscreen repairer.

    PubMed

    Fremlin, G; Sansom, J

    2014-10-01

    We report a case of an allergic skin reaction to ultraviolet-cured acrylates in a windscreen repair worker. The patient presented with a 6 month history of fingertip dryness, vesicles and desquamation. He had worked as a self-employed car windscreen repairer for 19 years. Previous management with vinyl glove protection and treatment with clobetasol propionate ointment had produced little improvement. He was patch tested to the British Society for Cutaneous Allergy standard and preservatives series and to the two acrylates used in his work environment, identified using safety data sheets, methyl methacrylate 2% pet and 2-hydroxyethylmethacrylate (2-HEMA) 2% pet. A positive reaction was seen at Day 4 to 2-HEMA, but all other patch tests were negative. An occupational allergic contact dermatitis to 2-HEMA was diagnosed. The patient was given avoidance advice and advised to use nitrile gloves. Although he was unable to give up his current work, he has continued his job using nitrile gloves with marked improvement. © The Author 2014. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. Mechanical and Vibration Testing of Carbon Fiber Composite Material with Embedded Piezoelectric Sensors

    NASA Technical Reports Server (NTRS)

    Duffy, Kirsten P.; Lerch, Bradley A.; Wilmoth, Nathan G.; Kray, Nicholas; Gemeinhardt, Gregory

    2012-01-01

    Piezoelectric materials have been proposed as a means of decreasing turbomachinery blade vibration either through a passive damping scheme, or as part of an active vibration control system. For polymer matrix fiber composite (PMFC) blades, the piezoelectric elements could be embedded within the blade material, protecting the brittle piezoceramic material from the airflow and from debris. Before implementation of a piezoelectric element within a PMFC blade, the effect on PMFC mechanical properties needs to be understood. This study attempts to determine how the inclusion of a packaged piezoelectric patch affects the material properties of the PMFC. Composite specimens with embedded piezoelectric patches were tested in four-point bending, short beam shear, and flatwise tension configurations. Results show that the embedded piezoelectric material does decrease the strength of the composite material, especially in flatwise tension, attributable to failure at the interface or within the piezoelectric element itself. In addition, the sensing properties of the post-cured embedded piezoelectric materials were tested, and performed as expected. The piezoelectric materials include a non-flexible patch incorporating solid piezoceramic material, and two flexible patch types incorporating piezoelectric fibers. The piezoceramic material used in these patches was Navy Type-II PZT.

  15. Simulation of bone resorption-repair coupling in vitro.

    PubMed

    Jones, S J; Gray, C; Boyde, A

    1994-10-01

    In the normal adult human skeleton, new bone formation by osteoblasts restores the contours of bone surfaces following osteoclastic bone resorption, but the evidence for resorption-repair coupling remains circumstantial. To investigate whether sites of prior resorption, more than the surrounding unresorbed surface, attract osteoblasts or stimulate them to proliferate or make new matrix, we developed a simple in vitro system in which resorption-repair coupling occurs. Resorption pits were produced in mammalian dentine or bone slabs by culturing chick bone-derived cells on them for 2-3 days. The chick cells were swept off and the substrata reseeded with rat calvarial osteoblastic cells, which make bone nodules in vitro, for periods of up to 8 weeks. Cell positions and new bone formation were investigated by ordinary light microscopy, fluorescence and reflection confocal laser microscopy, and SEM, in stained and unstained samples. There was no evidence that the osteoblasts were especially attracted to, or influenced by, the sites of resorption in dentine or bone before cell confluence was reached. Bone formation was identified by light microscopy by the accumulation of matrix, staining with alizarin and calcein and by von Kossa's method, and confirmed by scanning electron microscopy (SEM) by using backscattered electron (BSE) and transmitted electron imaging of unembedded samples and BSE imaging of micro-milled embedded material. These new bone patches were located initially in the resorption pits. The model in vitro system may throw new light on the factors that control resorption-repair coupling in the mineralised tissues in vivo.

  16. A rare postoperative complication of anterior lower thoracic instrumentation: diaphragmatic laceration with hemothorax.

    PubMed

    Wong, Yat Wa; Cheung, Jason Pui Yin; Luk, Keith Dip Kei; Cheung, Kenneth Man Chee

    2017-05-01

    To highlight the importance of preventing visceral injury due to prominent anterior implants at the spinal column. A 52-year-old man with cord compression was treated with a T9/10 discectomy and instrumented fusion via a right thoracotomy and trans-pleural approach. Postoperatively, he had improved lower limb numbness. However, after a bout of coughing, there was sudden increase in chest drain output, hemodynamic instability and massive fluid collection in the right chest cavity. Emergency re-exploration of the thoracotomy was performed and a 6 cm laceration of the right postero-medial diaphragm was identified as the bleeding source and was found to be in close proximity with the locking nut of the anterior implants. The laceration was repaired and a soft synthetic patch was used to cover the implants. Postoperatively, the hemothorax resolved and the patient recovered from the neurological deficit. Prevention of diaphragmatic injury can be performed using lower profile and less sharp-edged implants. Implant coverage with a soft synthetic material is necessary if unable to perform direct repair of the parietal pleura over the implants.

  17. Surgical repair of tricuspid valve leaflet tear following percutaneous closure of perimembranous ventricular septal defect using Amplatzer duct occluder I: Report of two cases

    PubMed Central

    Kuwelker, Saatchi Mahesh; Shetty, Devi Prasad; Dalvi, Bharat

    2017-01-01

    Tricuspid valve (TV) injury following transcatheter closure of perimembranous ventricular septal defect (PMVSD) with Amplatzer ductal occluder I (ADO I), requiring surgical repair, is rare. We report two cases of TV tear involving the anterior and septal leaflets following PMVSD closure using ADO I. In both the patients, the subvalvular apparatus remained unaffected. The patients presented with severe tricuspid regurgitation (TR) 6 weeks and 3 months following the device closure. They underwent surgical repair with patch augmentation of the TV leaflets. Postoperatively, both are asymptomatic with a mild residual TR. PMID:28163430

  18. Structure and specificity of FEN-1 from Methanopyrus kandleri

    DOE PAGES

    Shah, Santosh; Dunten, Pete; Stiteler, Amanda; ...

    2014-11-18

    DNA repair is fundamental to genome stability and is found in all three domains of life. However, many archaeal species, such as Methanopyrus kandleri, contain only a subset of the eukaryotic nucleotide excision repair (NER) homologues, and those present often contain significant differences compared to their eukaryotic homologues. To clarify the role of the NER XPG-like protein Mk0566 from M. kandleri, its biochemical activity and three dimensional structure were investigated. Ultimately, we found both to be more similar to human FEN-1 than human XPG, suggesting a biological role in replication and long-patch base excision repair rather than in NER.

  19. Investigation of contact allergy to dental materials by patch testing.

    PubMed

    Rai, Reena; Dinakar, Devina; Kurian, Swetha S; Bindoo, Y A

    2014-07-01

    Dental products are widely used by patients and dental personnel alike and may cause problems for both. Dental materials could cause contact allergy with varying manifestations such as burning, pain, stomatitis, cheilitis, ulcers, lichenoid reactions localized to the oral mucosa in patients, and hand dermatitis in dental personnel. Patch testing with the dental series comprising commonly used materials can be used to detect contact allergies to dental materials. This study aimed to identify contact allergy among patients who have oral mucosal lesions after dental treatment and among dental personnel who came in contact with these materials. Twenty patients who had undergone dental procedures with symptoms of oral lichen planus, oral stomatitis, burning mouth, and recurrent aphthosis, were included in the study. Dental personnel with history of hand dermatitis were also included in the study. Patch testing was performed using Chemotechnique Dental Series and results interpreted as recommended by the International Contact Dermatitis Research Group (ICDRG). Out of 13 patients who had undergone dental treatment/with oral symptoms, six patients with stomatitis, lichenoid lesions, and oral ulcers showed positive patch tests to a variety of dental materials, seven patients with ulcers had negative patch tests, seven dental personnel with hand dermatitis showed multiple allergies to various dental materials, and most had multiple positivities. The patch test is a useful, simple, noninvasive method to detect contact allergies among patients and among dental personnel dealing with these products. Long term studies are necessary to establish the relevance of these positive patch tests by eliminating the allergic substances, identifying clinical improvement, and substituting with nonallergenic materials.

  20. Repair process and a repaired component

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roberts, III, Herbert Chidsey; Simpson, Stanley F.

    Matrix composite component repair processes are disclosed. The matrix composite repair process includes applying a repair material to a matrix composite component, securing the repair material to the matrix composite component with an external securing mechanism and curing the repair material to bond the repair material to the matrix composite component during the securing by the external securing mechanism. The matrix composite component is selected from the group consisting of a ceramic matrix composite, a polymer matrix composite, and a metal matrix composite. In another embodiment, the repair process includes applying a partially-cured repair material to a matrix composite component,more » and curing the repair material to bond the repair material to the matrix composite component, an external securing mechanism securing the repair material throughout a curing period, In another embodiment, the external securing mechanism is consumed or decomposed during the repair process.« less

  1. Use of a platelet-rich fibrin membrane to repair traumatic tympanic membrane perforations: a comparative study.

    PubMed

    Gür, Özer Erdem; Ensari, Nuray; Öztürk, Mehmet Türker; Boztepe, Osman Fatih; Gün, Taylan; Selçuk, Ömer Tarık; Renda, Levent

    2016-10-01

    (1) To evaluate the effects of a platelet-rich fibrin (PRF) membrane in the repair of traumatic tympanic membrane (TM) perforations; and (2) to compare the use of a PRF membrane with the paper patch technique with regard to recovery rates, healing time, and correction of the mean air-bone gap. A randomized, prospective analysis was performed for 60 patients who were treated for traumatic TM perforations using one of the two methods. Closure rate, speed of healing, and hearing gain were compared between the PRF (Group 1) and paper patch (Group 2) groups. Closure was obtained in 28 (93%) perforations in Group 1 and 25 (83%) perforations in Group 2 (p > 0.05). On day 10, full closure of the TM was observed in 24 (80%) patients in Group 1 and 16 (53%) patients in Group 2 (p < 0.05). The improvement in the mean air-bone gap was 14.1 dB in Group 1 and 12.4 dB in Group 2 on post-operative day 45 (p < 0.05). In comparison with the paper patch method, PRF, a new method, provided more rapid healing with more successful audiological results, and with no requirement for a second procedure.

  2. Investigation of contact allergy to dental materials by patch testing

    PubMed Central

    Rai, Reena; Dinakar, Devina; Kurian, Swetha S.; Bindoo, Y. A.

    2014-01-01

    Background: Dental products are widely used by patients and dental personnel alike and may cause problems for both. Dental materials could cause contact allergy with varying manifestations such as burning, pain, stomatitis, cheilitis, ulcers, lichenoid reactions localized to the oral mucosa in patients, and hand dermatitis in dental personnel. Patch testing with the dental series comprising commonly used materials can be used to detect contact allergies to dental materials. Aim: This study aimed to identify contact allergy among patients who have oral mucosal lesions after dental treatment and among dental personnel who came in contact with these materials. Materials and Methods: Twenty patients who had undergone dental procedures with symptoms of oral lichen planus, oral stomatitis, burning mouth, and recurrent aphthosis, were included in the study. Dental personnel with history of hand dermatitis were also included in the study. Patch testing was performed using Chemotechnique Dental Series and results interpreted as recommended by the International Contact Dermatitis Research Group (ICDRG). Results: Out of 13 patients who had undergone dental treatment/with oral symptoms, six patients with stomatitis, lichenoid lesions, and oral ulcers showed positive patch tests to a variety of dental materials, seven patients with ulcers had negative patch tests, seven dental personnel with hand dermatitis showed multiple allergies to various dental materials, and most had multiple positivities. Conclusion: The patch test is a useful, simple, noninvasive method to detect contact allergies among patients and among dental personnel dealing with these products. Long term studies are necessary to establish the relevance of these positive patch tests by eliminating the allergic substances, identifying clinical improvement, and substituting with nonallergenic materials. PMID:25165644

  3. Compressive strength of damaged and repaired composite plates

    NASA Technical Reports Server (NTRS)

    Finn, Scott R.; He, Yi-Fei; Springer, George S.; Lee, Hung-Joo

    1992-01-01

    Tests were performed assessing the effectiveness of repair in restoring the mechanical properties of damaged, solid composite plates made either of Fiberite T300/976 graphite-epoxy, Fiberite IM7/977-2 graphite-toughened epoxy, or ICI APC-2 graphite-PEEK. The plate length, the layup and the amount of damage were also varied. Damage was introduced in the plates either by impacting them with a solid projectile or by applying a transverse static load. Some (75 percent) or all (100 percent) of the damaged zone was then cut out, and the plate was repaired by plugging and patching the hole. The effectiveness of the repair was evaluated by measuring the compressive strengths of undamaged plates, damaged plates with no cutout, damaged plates with a cutout, and repaired plates. The data at an intermediate stage of repair provide information on the effect of each repair step on the compressive strength. The results indicated that for the solid plates used in these tests, the repair methods used herein did not improve the compressive strength of already damaged plates.

  4. Turbine repair process, repaired coating, and repaired turbine component

    DOEpatents

    Das, Rupak; Delvaux, John McConnell; Garcia-Crespo, Andres Jose

    2015-11-03

    A turbine repair process, a repaired coating, and a repaired turbine component are disclosed. The turbine repair process includes providing a turbine component having a higher-pressure region and a lower-pressure region, introducing particles into the higher-pressure region, and at least partially repairing an opening between the higher-pressure region and the lower-pressure region with at least one of the particles to form a repaired turbine component. The repaired coating includes a silicon material, a ceramic matrix composite material, and a repaired region having the silicon material deposited on and surrounded by the ceramic matrix composite material. The repaired turbine component a ceramic matrix composite layer and a repaired region having silicon material deposited on and surrounded by the ceramic matrix composite material.

  5. Dynamic Analysis with Fibre Optic Sensors for Structural Health Monitoring

    DTIC Science & Technology

    2006-10-01

    cracked thick aluminum plate repaired with a bonded composite patch using transmission-type extrinsic Fabry – Perot interferometric optical fiber...and optical filtering have been used to demodulate returned Bragg signals. Due to the passive nature of the interrogation unit, system bandwidth is

  6. Angle-ply biomaterial scaffold for annulus fibrosus repair replicates native tissue mechanical properties, restores spinal kinematics, and supports cell viability.

    PubMed

    Borem, Ryan; Madeline, Allison; Walters, Joshua; Mayo, Henry; Gill, Sanjitpal; Mercuri, Jeremy

    2017-08-01

    Annulus fibrosus (AF) damage commonly occurs due to intervertebral disc (IVD) degeneration/herniation. The dynamic mechanical role of the AF is essential for proper IVD function and thus it is imperative that biomaterials developed to repair the AF withstand the mechanical rigors of the native tissue. Furthermore, these biomaterials must resist accelerated degradation within the proteolytic environment of degenerate IVDs while supporting integration with host tissue. We have previously reported a novel approach for developing collagen-based, multi-laminate AF repair patches (AFRPs) that mimic the angle-ply architecture and basic tensile properties of the human AF. Herein, we further evaluate AFRPs for their: tensile fatigue and impact burst strength, IVD attachment strength, and contribution to functional spinal unit (FSU) kinematics following IVD repair. Additionally, AFRP resistance to collagenase degradation and cytocompatibility were assessed following chemical crosslinking. In summary, AFRPs demonstrated enhanced durability at high applied stress amplitudes compared to human AF and withstood radially-directed biaxial stresses commonly borne by the native tissue prior to failure/detachment from IVDs. Moreover, FSUs repaired with AFRPs and nucleus pulposus (NP) surrogates had their axial kinematic parameters restored to intact levels. Finally, carbodiimide crosslinked AFRPs resisted accelerated collagenase digestion without detrimentally effecting AFRP tensile properties or cytocompatibility. Taken together, AFRPs demonstrate the mechanical robustness and enzymatic stability required for implantation into the damaged/degenerate IVD while supporting AF cell infiltration and viability. The quality of life for millions of individuals globally is detrimentally impacted by IVD degeneration and herniation. These pathologies often result in the structural demise of IVD tissue, particularly the annulus fibrosus (AF). Biomaterials developed for AF repair have yet to demonstrate the mechanical strength and durability required for utilization in the spine. Herein, we demonstrate the development of an angle-ply AF repair patch (AFRP) that can resist the application of physiologically relevant stresses without failure and which contributes to the restoration of functional spinal unit axial kinematics following repair. Furthermore, we show that this biomaterial can resist accelerated degradation in a simulated degenerate environment and supports AF cell viability. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  7. Valve-sparing options in tetralogy of Fallot surgery.

    PubMed

    Bacha, Emile

    2012-01-01

    Given late outcomes of patients with tetralogy of Fallot repaired in the 1970s and 1980s, as well as a better understanding of the late deleterious effects of pulmonary regurgitation, there is a tendency toward preservation of the pulmonary valve function during primary repair of tetralogy of Fallot. The bar keeps moving downward, to include smaller and more dysmorphic pulmonary valves. This article reviews some useful indications and techniques for valve-sparing options, including intraoperative balloon dilation and cusp reconstruction using a patch. Just like other valve repair techniques, no one technique can be applied uniformly, and surgeons must master a wide armamentarium of techniques. Copyright © 2012 Elsevier Inc. All rights reserved.

  8. Volatility of fragrance chemicals: patch testing implications.

    PubMed

    Gilpin, Sarah J; Hui, Xiaoying; Maibach, Howard I

    2009-01-01

    Diagnostic and predictive patch testing to determine contact allergy due to fragrance materials requires applying a fixed dose of material to the skin. This dose can be affected by the volatile nature of fragrances; little data exist on how the loss of fragrance dose due to volatility affects patch testing. (1) To evaluate pH dependence and evaporation rates of two fragrance chemicals, geraniol, citronellol, and a common fragrance solvent, diethyl phthalate (DEP) and (2) Assess implications for predictive patch-testing methods for fragrances. pH analysis of each material at 1% for three values (4.0, 5.0, 7.0) was done over 40 hours. Volatility experiments for each material, nonradiolabeled and radiolabeled, were conducted over a 24-hour period, taking readings at six time points (5 minutes, 15 minutes, 40 minutes, 1 hour, 3 hours, and 24 hours). Evaporation rates were not sensitive to pH shifts from 4.0 to 7.0. Evaporation rates for nonradiolabeled materials were low: after 24 hours, geraniol lost 8.9%, citronellol 27.0% and DEP 14.5%. The volatility data for radiolabeled materials demonstrated that geraniol loses up to 39% of its dose, citronellol loses up to 26%, and DEP up to 14% within 40 minutes. The tendency of fragrance materials to evaporate can impact the dose being applied to the patch and therefore the result of the patch and ultimately the decision-making process regarding that fragrance material's safety. These data, developed with DEP, utilized in a predictive sensitization assay cannot be generalized.

  9. [Right branch pulmonary artery stenosis with supravalvar aortic stenosis as a complication of Lecompte maneuver for tetralogy of Fallot associated with absent pulmonary valve].

    PubMed

    Honda, Yoshihiro; Suzuki, Shoji; Kaga, Shigeaki; Yoshida, Yukiyo; Kimura, Mitsuhiro; Kamiya, Kentaro; Sakakibara, Kenji; Katsu, Masatake

    2015-05-01

    The patient was diagnosed with tetralogy of Fallot associated with absent pulmonary valve syndrome and a low birth weight of 1,912 g. He suffered from respiratory distress on day 14 and received non-invasive positive pressure ventilation. At 5 months of age and 4.1 kg, he underwent intracardiac repair including right ventricular outflow repair with a monocusp patch, patch closure of the ventricular septum defect and right pulmonary transposition to the anterior of the ascending aorta following the Lecompte maneuver for airway decompression. He was subsequently discharged to home and exhibited an uneventful clinical course with non-invasive positive pressure ventilation for 5 months postoperatively. However, right pulmonary artery and supra-aortic stenosis was noted 2 years after the operation. Computed tomography (CT) and angiography showed ascending aorta strangulation by the right pulmonary artery with right ventricular outflow regurgitation. Right pulmonary artery reconstruction using polytetrafluoroethylene graft interposition and repeat right ventricular outflow repair with bicuspid hand-sewn valves was therefore performed;the postoperative course was uneventful. Pre- and post-operative management using non-invasive positive pressure ventilation and airway decompression with pulmonary artery translocation is a useful strategy in patients exhibiting symptomatic tetralogy of Fallot associated with absent pulmonary valve syndrome in the neonatal period.

  10. Strand displacement synthesis by yeast DNA polymerase ε

    PubMed Central

    Ganai, Rais A.; Zhang, Xiao-Ping; Heyer, Wolf-Dietrich; Johansson, Erik

    2016-01-01

    DNA polymerase ε (Pol ε) is a replicative DNA polymerase with an associated 3′–5′ exonuclease activity. Here, we explored the capacity of Pol ε to perform strand displacement synthesis, a process that influences many DNA transactions in vivo. We found that Pol ε is unable to carry out extended strand displacement synthesis unless its 3′–5′ exonuclease activity is removed. However, the wild-type Pol ε holoenzyme efficiently displaced one nucleotide when encountering double-stranded DNA after filling a gap or nicked DNA. A flap, mimicking a D-loop or a hairpin structure, on the 5′ end of the blocking primer inhibited Pol ε from synthesizing DNA up to the fork junction. This inhibition was observed for Pol ε but not with Pol δ, RB69 gp43 or Pol η. Neither was Pol ε able to extend a D-loop in reconstitution experiments. Finally, we show that the observed strand displacement synthesis by exonuclease-deficient Pol ε is distributive. Our results suggest that Pol ε is unable to extend the invading strand in D-loops during homologous recombination or to add more than two nucleotides during long-patch base excision repair. Our results support the hypothesis that Pol ε participates in short-patch base excision repair and ribonucleotide excision repair. PMID:27325747

  11. Simulation tests to assess occupational exposure to airborne asbestos from artificially weathered asphalt-based roofing products.

    PubMed

    Sheehan, Patrick; Mowat, Fionna; Weidling, Ryan; Floyd, Mark

    2010-11-01

    Historically, asbestos-containing roof cements and coatings were widely used for patching and repairing leaks. Although fiber releases from these materials when newly applied have been studied, there are virtually no useful data on airborne asbestos fiber concentrations associated with the repair or removal of weathered roof coatings and cements, as most studies involve complete tear-out of old roofs, rather than only limited removal of the roof coating or cement during a repair job. This study was undertaken to estimate potential chrysotile asbestos fiber exposures specific to these types of roofing products following artificially enhanced weathering. Roof panels coated with plastic roof cement and fibered roof coating were subjected to intense solar radiation and daily simulated precipitation events for 1 year and then scraped to remove the weathered materials to assess chrysotile fiber release and potential worker exposures. Analysis of measured fiber concentrations for hand scraping of the weathered products showed 8-h time-weighted average concentrations that were well below the current Occupational Safety and Health Administration permissible exposure limit for asbestos. There was, however, visibly more dust and a few more fibers collected during the hand scraping of weathered products compared to the cured products previously tested. There was a notable difference between fibers released from weathered and cured roofing products. In weathered samples, a large fraction of chrysotile fibers contained low concentrations of or essentially no magnesium and did not meet the spectral, mineralogical, or morphological definitions of chrysotile asbestos. The extent of magnesium leaching from chrysotile fibers is of interest because several researchers have reported that magnesium-depleted chrysotile fibers are less toxic and produce fewer mesothelial tumors in animal studies than normal chrysotile fibers.

  12. Investigation on Flexure Test of Composite Beam of Repair Materials and Substrate Concrete for Durable Repair

    NASA Astrophysics Data System (ADS)

    Pattnaik, Rashmi R.; Rangaraju, Prasada Rao

    2014-12-01

    An experimental study was conducted on composite beam of repair materials and substrate concrete to investigate the failures of concrete repair due to differences in strength of repair materials and substrate concrete. In this investigation the flexural strength, load-deflection curves and failure patterns of the composite beam specimens are studied for the durability of the concrete repair. Flexure test was conducted to simulate tensile stress in the concrete repair material. Compressive strength and split tensile strength of the repair materials and substrate concrete are investigated to aid in the analysis of the concrete repair. It was observed that the repair materials of higher compressive strength than the substrate concrete are causing an incompatible failure in the concrete repair.

  13. A new technique for the closure of the lens capsule by laser welding.

    PubMed

    Pini, Roberto; Rossi, Francesca; Menabuoni, Luca; Lenzetti, Ivo; Yoo, Sonia; Parel, Jean-Marie

    2008-01-01

    A new method is presented for the closure of the lens capsule based on laser welding of suitably prepared patches of anterior capsular tissue. Experiments were performed in freshly enucleated porcine eyes. The patches were previously stained with a solution of indocyanine green in sterile water and then welded on the recipient capsule by means of diode laser radiation at 810 nm. The welded tissue revealed mechanical properties comparable to those of healthy tissue. This technique is proposed to repair capsular breaks and to provide the closure of the capsulorhexis in lens refilling procedures.

  14. Repair of damaged DNA in-vivo. Comprehensive progress report, August 1980-August 1983

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hanawalt, P.C.

    1983-07-01

    We have extended our characterization of long patch excision repair (LPER) and have demonstrated that LPER is not mutagenic (or error-prone); that the recA function is required for LPER, at least for its regulation; that the substrate for LPER is produced as a linear (not an exponential) function of uv (254 nm) dose; and that LPER can occur in uvr/sup -/ cells treated with N-methyl-N-nitro-N-nitrosoguanidine (MNNG). We have developed 3 methods for measuring the frequency of interstrand crosslinks in DNA and are now applying these methods to the study of the formation and repair of DNA crosslinks in E.Coli. Wemore » have developed a monoclonal antibody specific for thymine glycol in DNA, and are using it to study the repair of thymine glycol in E. coli.« less

  15. Fabrication of tissue engineered tympanic membrane patches using computer-aided design and injection molding.

    PubMed

    Hott, Morgan E; Megerian, Cliff A; Beane, Rich; Bonassar, Lawrence J

    2004-07-01

    The goal of the current study was to use computer-aided design and injection molding technologies to tissue engineer precisely shaped cartilage in the shape of butterfly tympanic membrane patches out of chondrocyte-seeded calcium alginate gels. Molds were designed on SolidWorks 2000 and built out of acrylonitrile butadiene styrene (ABS) using fused deposition modeling (FDM). Tympanic membrane patches were fabricated using bovine articular chondrocytes seeded at 50 x 10 cells/mL in 2% calcium alginate gels. Molded patches were cultured in vitro for up to 10 weeks and assessed biochemically, morphologically, and histologically. Unmolded patches demonstrated outstanding dimensional fidelity, with a volumetric precision of at least 3 microL, and maintained their shape well for up to 10 weeks of in vitro culture. Glycosaminoglycan and collagen content increased steadily over 10 weeks in culture, demonstrating continual deposition of new extracellular matrix consistent with new tissue development. The use of computer-aided design and injection molding technologies allows for the fabrication of very small, precisely shaped chondrocyte-seeded calcium alginate structures that faithfully maintain their shape during in vitro culture. In vitro fabrication of tympanic membrane patches with a precisely controlled geometry may have the potential to provide a minimally invasive alternative to traditional methods for the repair of chronic tympanic membrane perforations.

  16. Patch tests with fragrance materials and preservatives.

    PubMed

    de Groot, A C; Liem, D H; Nater, J P; van Ketel, W G

    1985-02-01

    179 patients suspected of cosmetic allergy were patch tested with a series of 16 fragrance materials and 9 preservatives. In 67 patients (37.4%), 1 or more of these substances gave positive reactions. In the group of fragrance materials, the largest numbers of positive patch test reactions were seen to isoeugenol, oak moss, geraniol, alpha-amylcinnamic alcohol, and a mixture of alpha-amylcinnamic aldehyde and alpha-hexylcinnamic aldehyde. The fragrance mix in the ICDRG standard series detected nearly 80% of cases of contact allergy to fragrance materials other than its constituents. In the group of preservatives, Kathon CG and quaternium-15 scored the highest number of positive reactions. It is argued that the commonly used patch test concentrations of 2% for oak moss and geraniol may be too low to detect all cases of sensitization.

  17. Fistula repair after hypospadias surgery using buccal mucosal graft.

    PubMed

    Hosseini, Jalil; Kaviani, Ali; Mohammadhosseini, Mojtaba; Rezaei, Alireza; Rezaei, Iraj; Javanmard, Babak

    2009-01-01

    The aim of this study was to evaluate the success rate of urethrocutaneous fistula repair using buccal mucosal graft in patients with a previous hypospadias repair. We reviewed records of our patients with urethrocutaneous fistula developed after hypospadias repair in whom buccal mucosal graft fistula repair had been performed. All of the patients had been followed up for 24 postoperative months. A successful surgical operation was defined as no fistula recurrence or urethral stricture. Retrograde urethrography and urethrocystoscopy would be performed in patients who had any history of decreased force and caliber of urine or any difficulty in urination. Fistula repair using buccal mucosa patch graft had been done in 14 children with urethrocutaneous fistula developing after hypospadias reconstruction. The mean age of the children was 8.70 +/- 1.99 years old (range, 4 to 11 years). Seven fistulas were in the midshaft, 4 were in the penoscrotal region, and 3 were in the coronal region. Repair of the fistulas was successful in 11 of 14 patients (78.6%). In the remaining children, the diameter of the fistula was smaller than that before the operation, offering a good opportunity for subsequent closure. Our findings showed that fistula repair using buccal mucosal graft can be one of the acceptable techniques for repairing fistulas developed after hypospadias repair.

  18. Asphalt Raking. Instructor Manual. Trainee Manual.

    ERIC Educational Resources Information Center

    Laborers-AGC Education and Training Fund, Pomfret Center, CT.

    This packet consists of the instructor and trainee manuals for an asphalt raking course. The instructor manual contains a course schedule for 4 days of instruction, content outline, and instructor outline. The trainee manual is divided into five sections: safety, asphalt basics, placing methods, repair and patching, and clean-up and maintenance.…

  19. Development and evaluation of thermoplastic street maintenance material

    NASA Technical Reports Server (NTRS)

    Siemens, W. D.

    1973-01-01

    An all-weather permanent street patching material was investigated for flexible and rigid pavements. The economic, operational, and material requirements are discussed along with the results of field tests with various mixtures of EVA resins and asphalt. Cost analyses for thermoplastic patching methods are included.

  20. Quality of inguinal hernia operative reports: room for improvement

    PubMed Central

    Ma, Grace W.; Pooni, Amandeep; Forbes, Shawn S.; Eskicioglu, Cagla; Pearsall, Emily; Brenneman, Fred D.; McLeod, Robin S.

    2013-01-01

    Background Operative reports (ORs) serve as the official documentation of surgical procedures. They are essential for optimal patient care, physician accountability and billing, and direction for clinical research and auditing. Nonstandardized narrative reports are often of poor quality and lacking in detail. We sought to audit the completeness of narrative inguinal hernia ORs. Methods A standardized checklist for inguinal hernia repair (IHR) comprising 33 variables was developed by consensus of 4 surgeons. Five high-volume IHR surgeons categorized items as essential, preferable or nonessential. We audited ORs for open IHR at 6 academic hospitals. Results We audited 213 ORs, and we excluded 7 femoral hernia ORs. Tension-free repairs were the most common (82.5%), and the plug-and-patch technique was the most frequent (52.9%). Residents dictated 59% of ORs. Of 33 variables, 15 were considered essential and, on average, 10.8 ± 1.3 were included. Poorly reported elements included first occurrence versus recurrent repair (8.3%), small bowel viability in incarcerated hernias (10.7%) and occurrence of intraoperative complications (32.5%). Of 18 nonessential elements, deep vein thrombosis prophylaxis, preoperative antibiotics and urgency were reported in 1.9%, 11.7% and 24.3% of ORs, respectively. Repair-specific details were reported in 0 to 97.1% of ORs, including patch sutured to tubercle (55.1%) and location of plug (67.0%). Conclusion Completeness of IHR ORs varied with regards to essential and nonessential items but were generally incomplete, suggesting there is opportunity for improvement, including implementation of a standardized synoptic OR. PMID:24284146

  1. Colloidal gas aphron foams: A novel approach to a hydrogel based tissue engineered myocardial patch

    NASA Astrophysics Data System (ADS)

    Johnson, Elizabeth Edna

    Cardiovascular disease currently affects an estimated 58 million Americans and is the leading cause of death in the US. Over 2.3 million Americans are currently living with heart failure a leading cause of which is acute myocardial infarction, during which a part of the heart muscle is damaged beyond repair. There is a great need to develop treatments for damaged heart tissue. One potential therapy involves replacement of nonfunctioning scar tissue with a patch of healthy, functioning tissue. A tissue engineered cardiac patch would be ideal for such an application. Tissue engineering techniques require the use of porous scaffolds, which serve as a 3-D template for initial cell attachment and grow-th leading to tissue formation. The scaffold must also have mechanical properties closely matching those of the tissues at the site of implantation. Our research presents a new approach to meet these design requirements. A unique interaction between poly(vinyl alcohol) and amino acids has been discovered by our lab, resulting in the production of novel gels. These unique synthetic hydrogels along with one natural hydrogel, alginate (derived from brown seaweed), have been coupled with a new approach to tissue scaffold fabrication using solid colloidal gas aphrons (CGAs). CGAs are colloidal foams containing uniform bubbles with diameters on the order of micrometers. Upon solidification the GCAs form a porous, 3-D network suitable for a tissue scaffold. The project encompasses four specific aims: (I) characterize hydrogel formation mechanism, (II) use colloidal gas aphrons to produce hydrogel scaffolds, (III) chemically and physically characterize scaffold materials and (IV) optimize and evaluate scaffold biocompatibility.

  2. Application of COMPONT Medical Adhesive Glue for Tension-Reduced Duraplasty in Decompressive Craniotomy

    PubMed Central

    Zhou, Yujia; Wang, Gesheng; Liu, Jialin; Du, Yong; Wang, Lei; Wang, Xiaoyong

    2016-01-01

    Background The aim of this study was to evaluate the application of medical adhesive glue for tension-reduced duraplasty in decompressive craniotomy. Material/Methods A total of 56 cases were enrolled for this study from Jan 2013 to May 2015. All patients underwent decompressive craniotomy and the dura was repaired in all of them with tension-reduced duraplasty using the COMPONT medical adhesive to glue artificial dura together. The postoperative complications and the healing of dura mater were observed and recorded. Results No wound infection, epidural or subdural hematoma, cerebrospinal fluid leakage, or other complications associated with the procedure occurred, and there were no allergic reactions to the COMPONT medical adhesive glue. The second-phase surgery of cranioplasty was performed at 3 to 6 months after the decompressive craniotomy in 32 out of the 56 cases. During the cranioplasty we observed no adherence of the artificial dura mater patch to the skin flap, no residual COMPONT glue, or hydropic or contracture change of tissue at the surgical sites. Additionally, no defect or weakening of the adherence between the artificial dura mater patch and the self dura matter occurred. Conclusions COMPONT medical adhesive glue is a safe and reliable tool for tension-reduced duraplasty in decompressive craniotomy. PMID:27752035

  3. Thin Films and Inflatable Applications in Exploration Habitat Structures

    NASA Technical Reports Server (NTRS)

    Frazier, Donald O.; Paley, Mark S.; Strong, Janet D.

    2005-01-01

    NASA's vision to return to the Moon and then extend human exploration to Mars will benefit from human habitat technology development using new and creative applications of polymer materials and concepts. Thin Film and Inflatable (TFVI) materials are particularly interesting for exploration applications due to their light weight and low volume. Whereas TF/I materials can be launched and carried from Earth to multiple and distant exploration sites without the constraints of upmass limitations, eventually, with recycling and reclamation efforts, these materials may be developed using in-situ resources. These materials can be useful for fabricating, patching and repairing vehicles, replacement parts and even habitat structures, as well as for developing stand-alone habitat structure technologies and for nested and integrated applications. TF/Is can also be ideal environmental containment vessels within lunar or Martian regolith walls or as liners inside caves or raw regolith exterior structures for the provisions of atmosphere containment, debris protection and cleanliness. Further, TFOs can be specialized and matured for various and diverse applications. The desired range of applications will require materials specification for such properties as transparency, elasticity, thermal conductivity, mechanical strength, heat capacity, chemical resistance, and permeability. This paper will discuss Marshall Space Flight Center's plans to analyze and prioritize TF/I materials properties and classifications and to develop applications for these highly desirable materials in human habitat construction projects on the Moon and Mars.

  4. Vena cava thrombectomy and primary repair after radical nephrectomy for renal cell carcinoma: single-center experience.

    PubMed

    Helfand, Brian T; Smith, Norm D; Kozlowski, James M; Eskandari, Mark K

    2011-01-01

    Inferior vena cava (IVC) reconstruction for locally advanced renal cell carcinoma (RCC) includes resection with and without interposition grafting, patch graft, or primary repair. The proposed benefits of lateral venorrhaphy and primary repair are avoidance of foreign material, a more expeditious repair, and preservation of lower extremity venous outflow. A single-center retrospective review of 22 patients with RCC and IVC tumor thrombus treated with radical nephrectomy, lateral venorrhaphy, thrombectomy, and primary vena cava repair between July 2002 and June 2009 was carried out. Demographic data, diagnostic information, radiographic cross-sectional imaging, and procedural outcomes were examined. Among the 13 men and nine women, the mean age was 62.1 years (42-83); mean tumor size was 9.8 cm (3-17 cm), and 90% (n = 18) of the cases with RCC were identified pathologically as clear cell adenocarcinoma; on the basis of the classification system adopted by Neves, level I was for 50% (n = 11), level II for 32% (n = 7), level III for 9% (n = 2), and level IV for 9% (n = 2) of the patients. All patients underwent en bloc radical nephrectomy with tumor thrombus removal and primary IVC repair. Mean total operative time was 547.9 ± 138.5 minutes, whereas mean IVC cross-clamp time was 10.8 minutes (6-29 minutes). There were no intraoperative deaths or pulmonary embolism and all IVC margins were found to be pathologically negative. Postoperative complications included one pulmonary embolism, one exacerbation of chronic lymphedema, and two cases of new onset erectile dysfunction. Mean follow-up was 36.4 ± 23.2 months (6-92 months). There were no radiographic or clinically significant changes in mean IVC diameter during follow-up. Five late deaths (23%) occurred as a result of metastatic RCC over a mean period of 24 months (range, 12-48), but without any local recurrences. For advanced RCC with tumor thrombus extension into the IVC, lateral venorrhaphy and primary IVC repair avoids complicated caval reconstructions and results in high patency rates with a low local tumor recurrence rate. Copyright © 2011 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.

  5. Strand displacement synthesis by yeast DNA polymerase ε.

    PubMed

    Ganai, Rais A; Zhang, Xiao-Ping; Heyer, Wolf-Dietrich; Johansson, Erik

    2016-09-30

    DNA polymerase ε (Pol ε) is a replicative DNA polymerase with an associated 3'-5' exonuclease activity. Here, we explored the capacity of Pol ε to perform strand displacement synthesis, a process that influences many DNA transactions in vivo We found that Pol ε is unable to carry out extended strand displacement synthesis unless its 3'-5' exonuclease activity is removed. However, the wild-type Pol ε holoenzyme efficiently displaced one nucleotide when encountering double-stranded DNA after filling a gap or nicked DNA. A flap, mimicking a D-loop or a hairpin structure, on the 5' end of the blocking primer inhibited Pol ε from synthesizing DNA up to the fork junction. This inhibition was observed for Pol ε but not with Pol δ, RB69 gp43 or Pol η. Neither was Pol ε able to extend a D-loop in reconstitution experiments. Finally, we show that the observed strand displacement synthesis by exonuclease-deficient Pol ε is distributive. Our results suggest that Pol ε is unable to extend the invading strand in D-loops during homologous recombination or to add more than two nucleotides during long-patch base excision repair. Our results support the hypothesis that Pol ε participates in short-patch base excision repair and ribonucleotide excision repair. © The Author(s) 2016. Published by Oxford University Press on behalf of Nucleic Acids Research.

  6. Patch testing custom isocyanate materials from the workplace.

    PubMed

    Burrows, Dianne; Houle, Marie-Claude; Holness, D Linn; DeKoven, Joel; Skotnicki, Sandy

    2015-01-01

    Patch testing with standard trays of commercially available allergens is the current practice for investigating suspected cases of isocyanate-induced allergic contact dermatitis (ACD). In some facilities, these standard trays are further supplemented with custom preparations of isocyanate-containing materials. The aim was to determine whether added value exists in patch testing patients to custom isocyanate preparations in suspected cases of ACD. We performed a retrospective analysis of 11 patients referred to our specialty clinic between January 2003 and March 2011 for suspected patients of ACD who had custom testing with isocyanate materials from their workplace. In addition to standard trays of allergens, all patients were patch tested with custom isocyanate materials from their workplaces. Three (27%) of 11 patients showed an added value in testing to custom isocyanate allergens. Of these 3 patients, one had a reaction that reinforced positive reactions to the standard isocyanate tray, but the other 2 (18%) had no reactions to any of the commercially available allergens. Because of the high proportion of reactions (27%), we recommend the use of custom testing to workplace isocyanate products as a supplement to current standard patch testing procedures.

  7. 46 CFR 59.10-20 - Patches in shells and tube sheets.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... BOILERS, PRESSURE VESSELS AND APPURTENANCES Welding Repairs to Boilers and Pressure Vessels in -Service... inside the drum or shell and sealed against leakage by welding. Such plates shall have a diameter of at... wasted portion with a new section. The ligaments between the tube holes may be joined by means of welding...

  8. The $7-Billion Patch for Campus Maintenance

    ERIC Educational Resources Information Center

    Carlson, Scott

    2009-01-01

    Colleges are facing a growing deferred-maintenance problem, which at many public institutions adds up to repair bills in the hundreds of millions of dollars. Sometimes state legislatures have not supported those colleges at levels needed to maintain campus infrastructure. But at the same time, colleges continue to expand their campuses even as…

  9. 46 CFR 59.10-20 - Patches in shells and tube sheets.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... BOILERS, PRESSURE VESSELS AND APPURTENANCES Welding Repairs to Boilers and Pressure Vessels in -Service... inside the drum or shell and sealed against leakage by welding. Such plates shall have a diameter of at... wasted portion with a new section. The ligaments between the tube holes may be joined by means of welding...

  10. 46 CFR 59.10-20 - Patches in shells and tube sheets.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... BOILERS, PRESSURE VESSELS AND APPURTENANCES Welding Repairs to Boilers and Pressure Vessels in -Service... inside the drum or shell and sealed against leakage by welding. Such plates shall have a diameter of at... wasted portion with a new section. The ligaments between the tube holes may be joined by means of welding...

  11. 46 CFR 59.10-20 - Patches in shells and tube sheets.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... BOILERS, PRESSURE VESSELS AND APPURTENANCES Welding Repairs to Boilers and Pressure Vessels in -Service... inside the drum or shell and sealed against leakage by welding. Such plates shall have a diameter of at... wasted portion with a new section. The ligaments between the tube holes may be joined by means of welding...

  12. 46 CFR 59.10-20 - Patches in shells and tube sheets.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... BOILERS, PRESSURE VESSELS AND APPURTENANCES Welding Repairs to Boilers and Pressure Vessels in -Service... inside the drum or shell and sealed against leakage by welding. Such plates shall have a diameter of at... wasted portion with a new section. The ligaments between the tube holes may be joined by means of welding...

  13. Repair of pig dura in vivo using temperature controlled CO(2) laser soldering.

    PubMed

    Forer, Boaz; Vasilyev, Tamar; Brosh, Tamar; Kariv, Noam; Gil, Ziv; Fliss, Dan M; Katzir, Abraham

    2005-10-01

    The purpose of this study was to demonstrate that laser soldering might be successfully used for closing holes or cuts in the dura layer, which encapsulates the brain. A temperature controlled fiberoptic CO(2) laser system and albumin solder were used for spot soldering of fascia patches to holes in the dura of farm pigs, in vitro and in vivo. The mean burst pressure of the soldered patches in the in vitro experiments was 190 +/- 88 mm Hg-significantly higher than typical maximum CSF pressure of 15 mm Hg. In the in vivo experiments the pigs showed no postoperative complications. Histopathological studies exhibited an accepted level of inflammatory reaction and showed no thermal damage to the underlying brain tissue. It has been clearly demonstrated that temperature controlled laser soldering is a very useful technique for the repair of the dura. It provides significant advantages over standard closure techniques: it is easy to apply, the bond is strong and watertight and the procedure is likely to be much faster than suturing. This research work will lead to clinical trials.

  14. Partial hammock valve: surgical repair in adulthood.

    PubMed

    Aramendi, José I; Rodríguez, Miguel A; Voces, Roberto; Pérez, Pedro; Rodrigo, David

    2006-09-01

    We describe a forme frustrée of hammock valve involving only the posterior mitral leaflet. Three adult patients were referred to surgery with the diagnosis of severe mitral regurgitation due to fibrosis of the posterior mitral leaflet. The final diagnosis was done intraoperatively. In all of them the posterior leaflet was attached to some accessory papillary muscles arranged en palisade, with three to four fused muscle heads producing restrictive leaflet motion in systole. Repair consisted in division of the papillary muscles, patch augmentation, and ring annuloplasty. This previously unreported lesion is congenital but manifests itself in adulthood.

  15. Novel engineered tendon-fibrocartilage-bone composite with cyclic tension for rotator cuff repair.

    PubMed

    Liu, Qian; Hatta, Taku; Qi, Jun; Liu, Haoyu; Thoreson, Andrew R; Amadio, Peter C; Moran, Steven L; Steinmann, Scott P; Gingery, Anne; Zhao, Chunfeng

    2018-05-15

    Surgical repair of rotator cuff tears presents a significant clinical challenge with high failure rates and inferior functional outcomes. Graft augmentation improves repair outcomes, however currently available grafting materials have limitations. While cell-seeded decellularized tendon slices may facilitate cell infiltration, promote tendon incorporation and preserve original mechanical strength, the unique fibrocartilage zone is yet to be successfully reestablished. In this study, we investigated the biological and mechanical properties of an engineered tendon-fibrocartilage-bone composite (TFBC) with cyclic tension (3% strain, 0.2 Hz). Decellularized TFBCs seeded with bone marrow-derived mesenchymal stem cell (BMSCs) sheets and subjected to mechanical stimulation for up to 7 days, were characterized by histology, immunohistochemistry, scanning electron microscopy, mechanical testing, and transcriptional regulation. The decellularized TFBC maintained native enthesis structure and properties. Mechanically stimulated TFBC-BMSC constructs displayed increased cell migration after 7 days of culture compared to static groups. The seeded cell sheet not only integrated well with tendon scaffold but also distributed homogeneously and aligned to the direction of stretch under dynamic culture. Developmental genes were regulated including, scleraxis which was significantly upregulated with mechanical stimulation. The Young's modulus of the cell-seeded constructs was significantly higher compared to the non-cell-seeded controls. In conclusion, the results of this study reveal that the TFBC-BMSC composite provides an ideal multilayer construct for cell seeding and growth, with mechanical preconditioning further enhances cell penetration and differentiation. The BMSC cell sheet revitalized TFBC in conjunction with mechanical stimulation could serve as a novel and primed biological patch to improve rotator cuff repair. This article is protected by copyright. All rights reserved.

  16. Electrophysiological and Electrochemical Methods Development for the Detection of Biologically Active Chemical Agents

    DTIC Science & Technology

    1988-11-01

    Bilayer ........................................... 14 5. Current-Voltage Curve for Gramacidin in a Lecithin -Sphingomyelin Patch Bilayer... lecithin (Avanti). 9 2. MATERIALS 2.1 Patch Microprobe Instrumentation. The basis of the microprobe system is an AxoPatch Patch- Clamping Amplifier System...histogram of 1024 events cut above 2 pA. Events sampled are thought to be from the same single gramacidin channel in a lecithin : sphingomyelin (5:1) patch

  17. Additive value of patch testing custom epoxy materials from the workplace at the occupational disease specialty clinic in Toronto.

    PubMed

    Houle, Marie-Claude; Holness, D Linn; Dekoven, Joel; Skotnicki, Sandy

    2012-01-01

    Allergic contact dermatitis (ACD) to epoxy resins is one of the major causes of occupationally induced ACD. Testing of custom epoxy materials from the workplace is often performed to diagnose ACD. The objective of this study was to investigate the additive value of patch testing custom-made epoxy materials. We retrospectively analyzed outcomes of 24 patients who were tested to custom epoxy resin materials between January 2002 and July 2011. For 11 patients (46%), the testing of their materials from work had no additional value (negative results). For 13 patients (54%), there was an additional value of testing custom allergens. Of those, 7 patients (54%) had positive reactions to custom epoxy materials that reinforced the test results found with the commercially available allergens, and 6 (46%) patients had positive reactions only to custom epoxy materials. Therefore, for 6 patients (25%), there was a definite additive value of testing custom epoxy materials because the allergy was discovered with custom testing and not with the commercially available allergens. Because of the high percentage (54%) of patients with additive value of patch testing custom epoxy materials, we think that the inclusion of actual workplace epoxy materials should be strongly considered when patch testing patients with occupational epoxy exposure.

  18. MG53-mediated cell membrane repair protects against acute kidney injury

    PubMed Central

    Lin, Peihui; Tan, Tao; Wang, Zhen; Chen, Ken; Zhou, Xinyu; Gumpper, Kristyn; Zhu, Hua; Ludwig, Thomas; Mohler, Peter J.; Rovin, Brad; Abraham, William T.; Zeng, Chunyu; Ma, Jianjie

    2015-01-01

    Injury to the renal proximal tubular epithelium (PTE) represents the underlying consequence of acute kidney injury (AKI) after exposure to various stressors, including nephrotoxins and ischemia/reperfusion (I/R). Although the kidney has the ability to repair itself after mild injury, insufficient repair of PTE cells may trigger inflammatory and fibrotic responses, leading to chronic renal failure. We report that MG53, a member of the TRIM family of proteins, participates in repair of injured PTE cells and protects against the development of AKI. We show that MG53 translocates to acute injury sites on PTE cells and forms a repair patch. Ablation of MG53 leads to defective membrane repair. MG53-deficient mice develop pronounced tubulointerstitial injury and increased susceptibility to I/R-induced AKI compared to wild-type mice. Recombinant human MG53 (rhMG53) protein can target injury sites on PTE cells to facilitate repair after I/R injury or nephrotoxin exposure. Moreover, in animal studies, intravenous delivery of rhMG53 ameliorates cisplatin-induced AKI without affecting the tumor suppressor efficacy of cisplatin. These findings identify MG53 as a vital component of reno-protection, and targeting MG53-mediated repair of PTE cells represents a potential approach to prevention and treatment of AKI. PMID:25787762

  19. Ventral incisional hernia (VIH) repair after liver transplantation (OLT) with a biological mesh: experience in 3 cases.

    PubMed

    Schaffellner, S; Sereinigg, M; Wagner, D; Jakoby, E; Kniepeiss, D; Stiegler, P; Haybäck, J; Müller, H

    2016-05-01

    Hernias after orthotopic liver transplant (OLT) occur in about 30 % of cases. Predisposing factors in liver cirrhotic patients of cases are ascites, low abdominal muscle mass and cachexia before and immunosuppression after OLT. Standard operative transplant-technique even in small hernias is to implant a mesh. For patients after liver transplantation a porcine non-cross linked biological patch being less immunogenic than synthetic and cross-linked meshes is chosen for ventral incisional hernia repair. 3 patients (1 female, 2 male), OLT indications Hepatitis C, exogenous- toxic cirrhosis, median-age 53 (51 - 56) and median time to hernia occurrence after OLT were 10 month (6 - 18 m) are documented. 2 patients suffered from diabetes, 2 from chronic-obstructive lung disease. Maintenance immunosuppressions were Everolimus in 1 patient, Everolimus + MMF in the second and Everolimus +Tacrolimus in the third patient. The biological was chosen for hernia repair due to the preexisting risk- factors. Meshes, 10 × 16 cm were placed, in IPOM (Intra-Peritonel-Onlay-Mesh) -position by relaparatomy. Insolvable, monofile, interrupted sutures were used. All patients recovered primarily, and were dismissed within 10 d post OP. No wound healing disorders or signs of postoperative infections occurred. All are free of hernia recurrence in a mean observation time of 22 month (10 - 36). The usage of porcine non-cross-linked biological patches seems feasible for incisional hernia repair after OLT. Wound infections in these patients have been observed with other meshes. Further investigation is needed to prove potential superiority of this biological to the other meshes. © Georg Thieme Verlag KG Stuttgart · New York.

  20. Early Results of Rheumatic Mitral Valve Repair.

    PubMed

    Petrone, Giuseppe; Theodoropoulos, Panagiotis; Punjabi, Prakash P

    2016-11-01

    Mitral valve repair (MVr) in rheumatic heart disease (RHD) remains challenging. The present authors' surgical experience of MVr in 56 patients with RHD operated in between January 2011 and September 2014 is reported. Among the patients (mean age 32 ± 11 years), 11 were in NYHA functional class II, 32 in class III, and seven in class IV. An adequate or oversized autologous pericardial patch was sutured to extend the coaptating edge of both the anterior leaflet (in 18 patients) and the posterior leaflet (in 30 patients). Neochordae were implanted as needed (n = 43), and leaflet thinning (n = 13), commissurotomy (n = 15) and chordal splitting (n = 9) were also performed. A rigid annuloplasty ring was implanted in 32 patients, and in 24 patients a complete flexible annuloplasty ring made from pericardium, 4 mm Gore-Tex tube graft or a Dacron patch was constructed. Repair was not attempted in 16 patients, with replacement using a mechanical bileaflet prosthesis being considered the only option. Intraoperative post-repair transesophageal echocardiography demonstrated competency, with trivial mitral regurgitation (MR) up to grade I in all patients and a minimum coaptation depth ≥5 mm. There were no intraoperative or in-hospital deaths. Clinical and echocardiographic evaluations were performed up to six weeks after surgery, at which time 51 patients were in NYHA classes I-II and five were in class III. Residual mild MR up to grade I was identified in six patients. No recurrence of MR was observed in any of the patients, and no patients were reoperated on. The lack of adequate access to anticoagulation medication and monitoring, in addition to religious/cultural bias to the type of prosthetic valve used in low-income countries, necessitates an increase in the numbers of rheumatic MVr.

  1. Continued evaluation of pothole patching equipment, materials, and processes.

    DOT National Transportation Integrated Search

    2014-06-14

    After the deaths of two Caltrans workers who were patching potholes in 2006-2007, Caltrans tasked the Advanced Highway Maintenance and Construction Technology (AHMCT) Research Center with developing a safer and more efficient means of patching pothol...

  2. Concrete patching guide : final report.

    DOT National Transportation Integrated Search

    2003-09-01

    Maintenance personnel often select a material for patching concrete based on what they have used in the past. However, each patching job has particular demands, which may be different from what was required in past applications. Also, the list of ava...

  3. Research notes : concrete patching guide.

    DOT National Transportation Integrated Search

    2004-05-01

    Maintenance personnel often select a material for patching concrete based on what they have used in the past. However, each patching job has particular demands, which may be different from what was required in past applications. Also, the list of ava...

  4. 21 CFR 870.3710 - Pacemaker repair or replacement material.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Pacemaker repair or replacement material. 870.3710... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3710 Pacemaker repair or replacement material. (a) Identification. A pacemaker repair or replacement material is an...

  5. 21 CFR 870.3710 - Pacemaker repair or replacement material.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Pacemaker repair or replacement material. 870.3710... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3710 Pacemaker repair or replacement material. (a) Identification. A pacemaker repair or replacement material is an...

  6. 21 CFR 870.3710 - Pacemaker repair or replacement material.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Pacemaker repair or replacement material. 870.3710... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3710 Pacemaker repair or replacement material. (a) Identification. A pacemaker repair or replacement material is an...

  7. 21 CFR 870.3710 - Pacemaker repair or replacement material.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Pacemaker repair or replacement material. 870.3710... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3710 Pacemaker repair or replacement material. (a) Identification. A pacemaker repair or replacement material is an...

  8. Concrete Finisher: Apprenticeship Course Outline. Apprenticeship and Industry Training. 4805.2

    ERIC Educational Resources Information Center

    Alberta Advanced Education, 2005

    2005-01-01

    The graduate of the Concrete Finisher apprenticeship program is a certified journeyperson who will be able to: (1) perform tests to confirm concrete quality; (2) interpret building codes, plans and specifications as they apply to the trade; (3) place and finish concrete in a professional manner; (4) cut, patch, maintain and repair concrete…

  9. Amplification of unscheduled DNA synthesis signal enables fluorescence-based single cell quantification of transcription-coupled nucleotide excision repair

    PubMed Central

    Wienholz, Franziska; Vermeulen, Wim

    2017-01-01

    Abstract Nucleotide excision repair (NER) comprises two damage recognition pathways: global genome NER (GG-NER) and transcription-coupled NER (TC-NER), which remove a wide variety of helix-distorting lesions including UV-induced damage. During NER, a short stretch of single-stranded DNA containing damage is excised and the resulting gap is filled by DNA synthesis in a process called unscheduled DNA synthesis (UDS). UDS is measured by quantifying the incorporation of nucleotide analogues into repair patches to provide a measure of NER activity. However, this assay is unable to quantitatively determine TC-NER activity due to the low contribution of TC-NER to the overall NER activity. Therefore, we developed a user-friendly, fluorescence-based single-cell assay to measure TC-NER activity. We combined the UDS assay with tyramide-based signal amplification to greatly increase the UDS signal, thereby allowing UDS to be quantified at low UV doses, as well as DNA-repair synthesis of other excision-based repair mechanisms such as base excision repair and mismatch repair. Importantly, we demonstrated that the amplified UDS is sufficiently sensitive to quantify TC-NER-derived repair synthesis in GG-NER-deficient cells. This assay is important as a diagnostic tool for NER-related disorders and as a research tool for obtaining new insights into the mechanism and regulation of excision repair. PMID:28088761

  10. Adhesive bonded structural repair. I - Materials and processes, damage assessment and repair

    NASA Astrophysics Data System (ADS)

    Wegman, Raymond F.; Tullos, Thomas R.

    1993-08-01

    A standard method for the repair of adhesive bonded and composite laminate structures is introduced. Suitable materials and equipment for making satisfactory repairs are identified. Methods by which structures may be inspected, both before and after repair, are discussed. The objective in selecting the methods and materials is to restore the structure to its original integrity, i.e., to make a permanent repair. The use of these methods is recommended to promote standardized repair procedures.

  11. Effect of Moisture Exchange on Interface Formation in the Repair System Studied by X-ray Absorption

    PubMed Central

    Lukovic, Mladena; Ye, Guang

    2015-01-01

    In concrete repair systems, material properties of the repair material and the interface are greatly influenced by the moisture exchange between the repair material and the substrate. If the substrate is dry, it can absorb water from the repair material and reduce its effective water-to-cement ratio (w/c). This further affects the hydration rate of cement based material. In addition to the change in hydration rate, void content at the interface between the two materials is also affected. In this research, the influence of moisture exchange on the void content in the repair system as a function of initial saturation level of the substrate is investigated. Repair systems with varying level of substrate saturation are made. Moisture exchange in these repair systems as a function of time is monitored by the X-ray absorption technique. After a specified curing age (3 d), the internal microstructure of the repair systems was captured by micro-computed X-ray tomography (CT-scanning). From reconstructed images, different phases in the repair system (repair material, substrate, voids) can be distinguished. In order to quantify the void content, voids were thresholded and their percentage was calculated. It was found that significantly more voids form when the substrate is dry prior to application of the repair material. Air, initially filling voids and pores of the dry substrate, is being released due to the moisture exchange. As a result, air voids remain entrapped in the repair material close to the interface. These voids are found to form as a continuation of pre-existing surface voids in the substrate. Knowledge about moisture exchange and its effects provides engineers with the basis for recommendations about substrate preconditioning in practice. PMID:28787801

  12. Novel Repair Concept for Composite Materials by Repetitive Geometrical Interlock Elements

    PubMed Central

    Hufenbach, Werner; Adam, Frank; Heber, Thomas; Weckend, Nico; Bach, Friedrich-Wilhelm; Hassel, Thomas; Zaremba, David

    2011-01-01

    Material adapted repair technologies for fiber-reinforced polymers with thermosetting matrix systems are currently characterized by requiring major efforts for repair preparation and accomplishment in all industrial areas of application. In order to allow for a uniform distribution of material and geometrical parameters over the repair zone, a novel composite interlock repair concept is introduced, which is based on a repair zone with undercuts prepared by water-jet technology. The presented numerical and experimental sensitivity analyses make a contribution to the systematic development of the interlock repair technology with respect to material and geometrical factors of influence. The results show the ability of the novel concept for a reproducible and automatable composite repair. PMID:28824134

  13. Low complication rate of sellar reconstruction by artificial dura mater during endoscopic endonasal transsphenoidal surgery.

    PubMed

    Ye, Yuanliang; Wang, Fuyu; Zhou, Tao; Luo, Yi

    2017-12-01

    To evaluate effect of sellar reconstruction during pituitary adenoma resection surgery by the endoscopic endonasal transsphenoidal approach using artificial cerebral dura mater patch.This was a retrospective study of 1281 patients who underwent endoscopic transsphenoidal resection for the treatment of pituitary adenomas between December 2006 and May 2014 at the Neurosurgery Department of the People's Liberation Army General Hospital. The patients were classified into 4 grades according to intraoperative cerebrospinal fluid (CSF) leakage site. All patients were followed up for 3 months by telephone and outpatient visits.One thousand seventy three (83.7%) patients underwent sellar reconstruction using artificial dura matter patched outside the sellar region (method A), 106 (8.3%) using artificial dura matter patched inside the sellar region (method B), and 102 (8.0%) using artificial dura matter and a mucosal flap (method C). Method A was used for grade 0-1 leakage, method B for grade 1 to 2 leakage, and method C for grade 2 to 3 leakage. During the 3-month follow-up, postoperative CSF leakage was observed in 7 patients (0.6%): 2 among patients who underwent method B (1.9%) and 5 among those who underwent method C (4.9%). Meningitis was diagnosed in 13 patients (1.0%): 2 among patients who underwent method A (0.2%), 4 among those who underwent method B (3.8%), and 7 among those who underwent method C (6.7%).Compared with other reconstruction methods, sellar reconstruction surgery that only use artificial dura mater as repair material had a low rate of complications. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  14. Possible Mafic Patches at Mons Malapert and Scott Crater Highlight the Value of Site Selection studies

    NASA Technical Reports Server (NTRS)

    Cooper, B. L.

    2007-01-01

    Possible areas of mafic material on the rim and floor of Scott crater (82.1 S, 48.5 E) and on the northeast flank of Mons Malapert (85.5 S, 0 E) are suggested by analysis of shadow-masked Clementine false-colorration images. Mafic materials can produce more oxygen than can highlands materials, and mafic materials close to the south pole may be important for propellant production for a future lunar mission. If the dark patches are confirmed as mafic materials, this finding would suggest that other mafic patches may also exist, perhaps even closer to the poles. These preliminary findings illustrate the need for additional site selection studies in the lunar polar regions, to improve our capability to "live off the land".

  15. Laparoscopic inguinal hernia repair: gold standard in bilateral hernia repair? Results of more than 2800 patients in comparison to literature.

    PubMed

    Wauschkuhn, Constantin Aurel; Schwarz, Jochen; Boekeler, Ulf; Bittner, Reinhard

    2010-12-01

    Advantages and disadvantages of open and endoscopic hernia surgery are still being discussed. Until now there has been no study that evaluated the advantages and disadvantages of bilateral hernia repair in a large number of patients. Our prospectively collected database was analyzed to compare the results of laparoscopic bilateral with laparoscopic unilateral hernia repair. We then compared these results with the results of a literature review regarding open and laparoscopic bilateral hernia repair. From April 1993 to December 2007 there were 7240 patients with unilateral primary hernia (PH) and 2880 patients with bilateral hernia (5760 hernias) who underwent laparoscopic transabdominal preperitoneal patch plastic (TAPP). Of the 10,120 patients, 28.5% had bilateral hernias. Adjusted for the number of patients operated on, the mean duration of surgery for unilateral hernia repair was shorter than that for bilateral repair (45 vs. 70 min), but period of disability (14 vs. 14 days) was the same. Adjusted for the number of hernias repaired, morbidity (1.9 vs. 1.4%), reoperation (0.5 vs. 0.43%), and recurrence rate (0.63 vs. 0.42%) were similar for unilateral versus bilateral repair, respectively. The review of the literature shows a significantly shorter time out of work after laparoscopic bilateral repair than after the bilateral open approach. Simultaneous laparoscopic repair of bilateral inguinal hernias does not increase the risk for the patient and has an equal length of down time compared with unilateral repair. According to literature, recovery after laparoscopic repair is faster than after open simultaneous repair. Laparoscopic/endoscopic inguinal hernia repair of bilateral hernias should be recommended as the gold standard.

  16. Immunoisolation Patch System for Cellular Transplantation

    NASA Technical Reports Server (NTRS)

    Wang, Taylor G. (Inventor)

    2014-01-01

    An immunoisolation patch system, and particularly a patch system comprising multiple immunoisolation microcapsules, each encapsulating biological material such as cells for transplantation, which can be used in the prophylactic and therapeutic treatment of disease in large animals and humans without the need for immunosuppression.

  17. The management of corneal trauma: advances in the past twenty-five years.

    PubMed

    Macsai, M S

    2000-09-01

    Over the past quarter century, advances in our understanding of corneal anatomy, physiology, and wound healing have all played an integral role in the management of corneal trauma. As the etiologies of corneal trauma have changed, so has our understanding of the impact of injury on corneal function as it relates to visual rehabilitation. Numerous new classes of antibiotics, antiinflammatory agents, and tissue adhesives have emerged. Occlusive therapy has advanced from simple pressure patching bandage soft contact lenses and collagen shields. Surgical instrumentation, operating microscopes, viscoelastic substances, and suture materials have all improved the outcomes of corneal trauma repair. Improved understanding of the refractive properties of the cornea through topography and alternative suture techniques has helped us restore the natural corneal curvature and visual outcomes. Consequently, in the last quarter of this century our therapeutic approaches to cornea trauma, both medical and surgical, have improved.

  18. Seal device for ferromagnetic containers

    DOEpatents

    Meyer, R.E.; Jason, A.J.

    1994-10-18

    A temporary seal or patch assembly prevents the escape of contents, e.g., fluids and the like, from within a container having a breach there through until the contents can be removed and/or a repair effected. A frame that supports a sealing bladder can be positioned over the breach and the frame is then attached to the container surface, which must be of a ferromagnet material, by using switchable permanent magnets. The permanent magnets are designed to have a first condition that is not attracted to the ferromagnetic surface and a second conditions whereby the magnets are attracted to the surface with sufficient force to support the seal assembly on the surface. Latching devices may be attached to the frame and engage the container surface with hardened pins to prevent the lateral movement of the seal assembly along the container surface from external forces such as fluid drag or gravity. 10 figs.

  19. Seal device for ferromagnetic containers

    DOEpatents

    Meyer, Ross E.; Jason, Andrew J.

    1994-01-01

    A temporary seal or patch assembly prevents the escape of contents, e.g., fluids and the like, from within a container having a breach therethrough until the contents can be removed and/or a repair effected. A frame that supports a sealing bladder can be positioned over the breach and the frame is then attached to the container surface, which must be of a ferromagnet material, by using switchable permanent magnets. The permanent magnets are designed to have a first condition that is not attracted to the ferromagnetic surface and a second conditions whereby the magnets are attracted to the surface with sufficient force to support the seal assembly on the surface. Latching devices may be attached to the frame and engage the container surface with hardened pins to prevent the lateral movement of the seal assembly along the container surface from external forces such as fluid drag or gravity.

  20. Comparison of prosthetic materials for abdominal wall reconstruction in the presence of contamination and infection.

    PubMed Central

    Brown, G L; Richardson, J D; Malangoni, M A; Tobin, G R; Ackerman, D; Polk, H C

    1985-01-01

    Abdominal wall defects resulting from trauma, invasive infection, or hernia present a difficult problem for the surgeon. In order to study the problems associated with the prosthetic materials used for abdominal wall reconstruction, an animal model was used to simulate abdominal wall defects in the presence of peritonitis and invasive infection. One hundred guinea pigs were repaired with either polytetrafluorethylene (PTFE) or polypropylene mesh (PPM). Our experiments included intra-operative contamination with Staphylococcus aureus. We found significantly fewer organisms (p less than 0.05) adherent to the PTFE than to the PPM when antibiotics were administered after surgery, as well as when no antibiotics were given. In the presence of peritonitis, we found no real difference in numbers of intraperitoneal bacteria present whether PTFE or PPM was used. In all instances, the PTFE patches produced fewer adhesions and were more easily removed. From these experiments, it appears that PTFE may be associated with fewer problems than PPM in the presence of contamination and infection. Images FIG. 1. PMID:3159353

  1. Outreach Materials for the Collision Repair Campaign

    EPA Pesticide Factsheets

    The Collision Repair Campaign offers outreach materials to help collision repair shops reduce toxic air exposure. Materials include a DVD, poster, training video, and materials in Spanish (materiales del outreach en español).

  2. Construction and characterization of mismatch-containing circular DNA molecules competent for assessment of nick-directed human mismatch repair in vitro.

    PubMed

    Larson, Erik D; Nickens, David; Drummond, James T

    2002-02-01

    The ability of cell-free extracts to correct DNA mismatches has been demonstrated in both prokaryotes and eukaryotes. Such an assay requires a template containing both a mismatch and a strand discrimination signal, and the multi-step construction process can be technically difficult. We have developed a three-step procedure for preparing DNA heteroduplexes containing a site-specific nick. The mismatch composition, sequence context, distance to the strand signal, and the means for assessing repair in each strand are adjustable features built into a synthetic oligonucleotide. Controlled ligation events involving three of the four DNA strands incorporate the oligonucleotide into a circular template and generate the repair-directing nick. Mismatch correction in either strand of a prototype G.T mismatch was achieved by placing a nick 10-40 bp away from the targeted base. This proximity of nick and mismatch represents a setting where repair has not been well characterized, but the presence of a nick was shown to be essential, as was the MSH2/MSH6 heterodimer, although low levels of repair occurred in extract defective in each protein. All repair events were inhibited by a peptide that interacts with proliferating cell nuclear antigen and inhibits both mismatch repair and long-patch replication.

  3. Endoscope-assisted laparoscopic repair of perforated peptic ulcers.

    PubMed

    Lee, Kun-Hua; Chang, Hung-Chi; Lo, Chong-Jeh

    2004-04-01

    Laparoscopic repairs for perforated peptic ulcer (PPU) are likely to fail in patients with shock, gastric outlet obstruction, or large perforations. This prospective study was performed to evaluate a revised approach of laparoscopic repair with endoscopic assistance to treat these patients. Between April 2001 and February 2002, 30 consecutive patients with PPU were enrolled in this study. The mean age was 43.1 +/- 12.2 years. Male to female ratio was 27:2. One patient was excluded from laparoscopic repair due to a gastric outlet obstruction. The other 29 patients were managed according to a protocol of preoperative upper endoscopy and laparoscopic intracorporeal suture repair with an omental patch. The average operative time was 58.1 +/- 13.5 minutes (range, 36-96 min). The average diameter of perforation was 4.2 +/- 2.0 mm (range, 1-12 mm). The average time to resume oral fluids was 3.2 +/- 0.8 days (range, 2-8 days). The average hospital stay was 4.7 +/- 1.1 days (range, 3-10 days). There was no leakage or mortality. Most patients did not receive parenteral analgesics postoperatively. We conclude that endoscope-assisted laparoscopic repair for PPU is safe and effective. This revised technique allows surgeons to exclude patients who are likely to fail the laparoscopic repair.

  4. Process for Self-Repair of Insulation Material

    NASA Technical Reports Server (NTRS)

    Parrish, Clyde F. (Inventor)

    2007-01-01

    A self-healing system for an insulation material initiates a self-repair process by rupturing a plurality of microcapsules disposed on the insulation material. When the plurality of microcapsules are ruptured reactants witlun the plurality of microcapsules react to form a replacement polymer in a break of the insulation material. This self-healing system has the ability to repair multiple breaks in a length of insulation material without exhausting the repair properties of the material.

  5. Process for self-repair of insulation material

    NASA Technical Reports Server (NTRS)

    Parrish, Clyde F. (Inventor)

    2007-01-01

    A self-healing system for an insulation material initiates a self-repair process by rupturing a plurality of microcapsules disposed on the insulation material. When the plurality of microcapsules are ruptured reactants within the plurality of microcapsules react to form a replacement polymer in a break of the insulation material. This self-healing system has the ability to repair multiple breaks in a length of insulation material without exhausting the repair properties of the material.

  6. Shuttle orbiter TPS flight repair kit development

    NASA Technical Reports Server (NTRS)

    1979-01-01

    The design and application of a TPS repair kit is presented. The repair kit is designed for on orbit use by a crew member working in the manned maneuvering unit (MMU). The kit includes the necessary equipment and materials to accomplish the repair tasks which include the following: HRSI emittance coating repair, damaged tile repair, missing tile repair, and multiple tile repair. Two types of repair materials required to do the small area repair and the large area repair are described. The materials area cure in place, silicone base ablator for small damaged areas and precured ablator tile for repair of larger damaged areas is examined. The cure in place ablator is also used as an adhesive to bond the precured tiles in place. An applicator for the cure in place ablator, designed to contain a two-part silicon compound, mix the two components at correct ratio, and dispense the materials at rates compatible with mission timelines established for the EVA is described.

  7. Re-generation of tissue about an animal-based scaffold: AMS studies of the fate of the scaffold

    NASA Astrophysics Data System (ADS)

    Rickey, Frank A.; Elmore, David; Hillegonds, Darren; Badylak, Stephen; Record, Rae; Simmons-Byrd, Abby

    2000-10-01

    Small intestinal submucosa (SIS) is an unusual tissue, which shows great promise for the repair of damaged tissues in humans. When the SIS is used as a surgical implant, the porcine-derived material is not rejected by the host immune system, and in fact stimulates the constructive re-modeling of damaged tissue. In dogs, these SIS scaffolds have been used to grow new arteries, tendons, and urinary bladders. Moreover, the SIS scaffold tissue seems to disappear from the implant region after a few months. The fate of this SIS tissue is of considerable importance if it is to be used in human tissue repair. SIS is obtained from pigs. We have labeled the SIS in several pigs by intraveneous administration of 14C enriched proline from the age of three weeks until they reach market weight. The prepared SIS was then implanted in dogs as scaffolds for urinary bladder patches. During the remaining life of each dog, blood, urine and feces samples were collected on a regular schedule. AMS analyses of these specimens were performed to measure the elimination rate of the SIS. At different intervals, the dogs were sacrificed. Tissue samples were analyzed by AMS to determine the whole-body distribution of the labeled SIS.

  8. Method for identifying known materials within a mixture of unknowns

    DOEpatents

    Wagner, John S.

    2000-01-01

    One or both of two methods and systems are used to determine concentration of a known material in an unknown mixture on the basis of the measured interaction of electromagnetic waves upon the mixture. One technique is to utilize a multivariate analysis patch technique to develop a library of optimized patches of spectral signatures of known materials containing only those pixels most descriptive of the known materials by an evolutionary algorithm. Identity and concentration of the known materials within the unknown mixture is then determined by minimizing the residuals between the measurements from the library of optimized patches and the measurements from the same pixels from the unknown mixture. Another technique is to train a neural network by the genetic algorithm to determine the identity and concentration of known materials in the unknown mixture. The two techniques may be combined into an expert system providing cross checks for accuracy.

  9. System for identifying known materials within a mixture of unknowns

    DOEpatents

    Wagner, John S.

    1999-01-01

    One or both of two methods and systems are used to determine concentration of a known material in an unknown mixture on the basis of the measured interaction of electromagnetic waves upon the mixture. One technique is to utilize a multivariate analysis patch technique to develop a library of optimized patches of spectral signatures of known materials containing only those pixels most descriptive of the known materials by an evolutionary algorithm. Identity and concentration of the known materials within the unknown mixture is then determined by minimizing the residuals between the measurements from the library of optimized patches and the measurements from the same pixels from the unknown mixture. Another technique is to train a neural network by the genetic algorithm to determine the identity and concentration of known materials in the unknown mixture. The two techniques may be combined into an expert system providing cross checks for accuracy.

  10. System for identifying known materials within a mixture of unknowns

    DOEpatents

    Wagner, J.S.

    1999-07-20

    One or both of two methods and systems are used to determine concentration of a known material in an unknown mixture on the basis of the measured interaction of electromagnetic waves upon the mixture. One technique is to utilize a multivariate analysis patch technique to develop a library of optimized patches of spectral signatures of known materials containing only those pixels most descriptive of the known materials by an evolutionary algorithm. Identity and concentration of the known materials within the unknown mixture is then determined by minimizing the residuals between the measurements from the library of optimized patches and the measurements from the same pixels from the unknown mixture. Another technique is to train a neural network by the genetic algorithm to determine the identity and concentration of known materials in the unknown mixture. The two techniques may be combined into an expert system providing cross checks for accuracy. 37 figs.

  11. VRPI Thermoresponsive Reversibly Attachable Patch for Temporary Intervention in Ocular Trauma

    DTIC Science & Technology

    2014-09-01

    Polymerization (ATRP) on biocompatible substrates (e.g. parylene, polyimide , etc.). Adhesion data performed on preliminary samples under uniaxial testing...adhesion performance is completed in vitro, adhesion in vivo and biocompatibility will be assessed using a rabbit animal model. 15. SUBJECT TERMS...vitro, validate adhesive performance in vivo and perform preliminary biocompatibility assessments. 2. Keywords. sutureless wound repair

  12. Preconditioning allows engraftment of mouse and human embryonic lung cells, enabling lung repair in mice.

    PubMed

    Rosen, Chava; Shezen, Elias; Aronovich, Anna; Klionsky, Yael Zlotnikov; Yaakov, Yasmin; Assayag, Miri; Biton, Inbal Eti; Tal, Orna; Shakhar, Guy; Ben-Hur, Herzel; Shneider, David; Vaknin, Zvi; Sadan, Oscar; Evron, Shmuel; Freud, Enrique; Shoseyov, David; Wilschanski, Michael; Berkman, Neville; Fibbe, Willem E; Hagin, David; Hillel-Karniel, Carmit; Krentsis, Irit Milman; Bachar-Lustig, Esther; Reisner, Yair

    2015-08-01

    Repair of injured lungs represents a longstanding therapeutic challenge. We show that human and mouse embryonic lung tissue from the canalicular stage of development (20-22 weeks of gestation for humans, and embryonic day 15-16 (E15-E16) for mouse) are enriched with progenitors residing in distinct niches. On the basis of the marked analogy to progenitor niches in bone marrow (BM), we attempted strategies similar to BM transplantation, employing sublethal radiation to vacate lung progenitor niches and to reduce stem cell competition. Intravenous infusion of a single cell suspension of canalicular lung tissue from GFP-marked mice or human fetal donors into naphthalene-injured and irradiated syngeneic or SCID mice, respectively, induced marked long-term lung chimerism. Donor type structures or 'patches' contained epithelial, mesenchymal and endothelial cells. Transplantation of differentially labeled E16 mouse lung cells indicated that these patches were probably of clonal origin from the donor. Recipients of the single cell suspension transplant exhibited marked improvement in lung compliance and tissue damping reflecting the energy dissipation in the lung tissues. Our study provides proof of concept for lung reconstitution by canalicular-stage human lung cells after preconditioning of the pulmonary niche.

  13. Simple patch closure for perforated peptic ulcer in children followed by helicobacter pylori eradication.

    PubMed

    Yildiz, Turan; Ilce, Huri Tilla; Ceran, Canan; Ilce, Zekeriya

    2014-05-01

    Peptic ulcer disease in children is rare. Therefore, the diagnosis can be missed until complications such as perforation or hemorrhage occur. Few reports have investigated the procedures and outcomes of children who have undergone operations for perforated duodenal ulcers. We report our experience with the modified Graham technique for perforated duodenal ulcers in nine children and review the literature. Methods : The records of patients operated on for a perforated duodenal ulcer in the last 8 years in two pediatric surgery centers were evaluated retrospectively. Patient demographics, symptoms, time to admission to hospital, operative findings, and postoperative clinical course were evaluated. Results : Nine children (mean age 13.2 years, range 6-170 years) were included. All patients were admitted in the first six hours after their abdominal pain started. In three patients, there was free air on plain x-rays, while the x-rays were normal in six. All perforations were located on the anterior surface of the first part of the duodenum and repaired with primary suturing and Graham patch omentoplasty. The recovery was uneventful in all patients. In five patients, urea breath tests were performed postoperatively for Helicobacter Pylori, and the results were positive. All patients underwent triple therapy with lansoprazole, amoxicillin, and clarithromycin. The mean follow-up time was 58 (range 3-94) months. Conclusions : Peptic ulcer perforation should be suspected in children who have acute abdominal pain and peritoneal signs, especially when their suffering is intense. The simple patch repair and postoperative triple therapy for Helicobacter Pylori are safe and satisfactory for treating peptic ulcer perforation in children.

  14. Improving left ventricular outflow tract obstruction repair in common atrioventricular canal defects.

    PubMed

    Myers, Patrick O; del Nido, Pedro J; Marx, Gerald R; Emani, Sitaram; Mayer, John E; Pigula, Frank A; Baird, Christopher W

    2012-08-01

    Left ventricular outflow tract obstruction (LVOTO) is the second most frequent reason for reoperation after atrioventricular canal (AVC) defect repair. Limited data are available on the mechanisms of LVOTO, their treatment, and outcomes. Between 1998 and 2010, 56 consecutive children with AVC underwent 68 LVOTO procedures. The AVC was partial in 4, transitional in 9, and complete in 43. The LVOTO procedure was required in 21 patients at the primary AVC repair, and the initial LVOTO procedure in 35 patients was a late reoperation after AVC repair. During a mean follow-up of 50±41 months, 5 patients (24%) with LVOTO repair at AVC repair required a reoperation for LVOTO, and 7 patients (20%) whose initial LVOTO repair was a reoperation required a second reoperation for LVOTO repair. Overall freedom from LVOTO reoperation was 98.5% at 1 year, 92.5% at 3 years, 81% at 5 years, 72.2% at 7 years, and 52.5% at 10 and 12 years. The freedom from reoperation was neither significantly different between partial, transitional, and complete AVC (p=0.78) nor between timing of the LVOT procedure (p=0.49). Modified single-patch AVC repair was associated with a higher LVOTO reoperation rate (p=0.04). Neither the mechanisms leading to LVOTO nor the surgical techniques used were independent predictors of reoperation. LVOTO in AVC is a complex and multifactorial disease. Aggressive surgical repair has improved late outcomes; however, risk factors for reoperation and the ideal approach for repair remain to be defined. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  15. The estimation of material and patch parameters in a PDE-based circular plate model

    NASA Technical Reports Server (NTRS)

    Banks, H. T.; Smith, Ralph C.; Brown, D. E.; Metcalf, Vern L.; Silcox, R. J.

    1995-01-01

    The estimation of material and patch parameters for a system involving a circular plate, to which piezoceramic patches are bonded, is considered. A partial differential equation (PDE) model for the thin circular plate is used with the passive and active contributions form the patches included in the internal and external bending moments. This model contains piecewise constant parameters describing the density, flexural rigidity, Poisson ratio, and Kelvin-Voigt damping for the system as well as patch constants and a coefficient for viscous air damping. Examples demonstrating the estimation of these parameters with experimental acceleration data and a variety of inputs to the experimental plate are presented. By using a physically-derived PDE model to describe the system, parameter sets consistent across experiments are obtained, even when phenomena such as damping due to electric circuits affect the system dynamics.

  16. A 3D Lattice Modelling Study of Drying Shrinkage Damage in Concrete Repair Systems

    PubMed Central

    Luković, Mladena; Šavija, Branko; Schlangen, Erik; Ye, Guang; van Breugel, Klaas

    2016-01-01

    Differential shrinkage between repair material and concrete substrate is considered to be the main cause of premature failure of repair systems. The magnitude of induced stresses depends on many factors, for example the degree of restraint, moisture gradients caused by curing and drying conditions, type of repair material, etc. Numerical simulations combined with experimental observations can be of great use when determining the influence of these parameters on the performance of repair systems. In this work, a lattice type model was used to simulate first the moisture transport inside a repair system and then the resulting damage as a function of time. 3D simulations were performed, and damage patterns were qualitatively verified with experimental results and cracking tendencies in different brittle and ductile materials. The influence of substrate surface preparation, bond strength between the two materials, and thickness of the repair material were investigated. Benefits of using a specially tailored fibre reinforced material, namely strain hardening cementitious composite (SHCC), for controlling the damage development due to drying shrinkage in concrete repairs was also examined. PMID:28773696

  17. A 3D Lattice Modelling Study of Drying Shrinkage Damage in Concrete Repair Systems.

    PubMed

    Luković, Mladena; Šavija, Branko; Schlangen, Erik; Ye, Guang; van Breugel, Klaas

    2016-07-14

    Differential shrinkage between repair material and concrete substrate is considered to be the main cause of premature failure of repair systems. The magnitude of induced stresses depends on many factors, for example the degree of restraint, moisture gradients caused by curing and drying conditions, type of repair material, etc. Numerical simulations combined with experimental observations can be of great use when determining the influence of these parameters on the performance of repair systems. In this work, a lattice type model was used to simulate first the moisture transport inside a repair system and then the resulting damage as a function of time. 3D simulations were performed, and damage patterns were qualitatively verified with experimental results and cracking tendencies in different brittle and ductile materials. The influence of substrate surface preparation, bond strength between the two materials, and thickness of the repair material were investigated. Benefits of using a specially tailored fibre reinforced material, namely strain hardening cementitious composite (SHCC), for controlling the damage development due to drying shrinkage in concrete repairs was also examined.

  18. A rare allergy to a polyether dental impression material.

    PubMed

    Mittermüller, Pauline; Szeimies, Rolf-Markus; Landthaler, Michael; Schmalz, Gottfried

    2012-08-01

    Polyether impression materials have been used in dentistry for more than 40 years. Allergic reactions to these materials such as reported in the 1970s ceased after replacement of a catalyst. Very recently, however, patients have started to report symptoms that suggest a new allergic reaction from polyether impression materials. Here, we report on the results of allergy testing with polyether impression materials as well as with its components. Eight patients with clinical symptoms of a contact allergy (swelling, redness or blisters) after exposure to a polyether impression material were subjected to patch tests, two of them additionally to a prick test. A further patient with atypical symptoms of an allergy (nausea and vomiting after contact with a polyether impression material in the oral cavity) but with a history of other allergic reaction was also patch tested. The prick tests showed no immediate reactions in the two patients tested. In the patch tests, all eight patients with typical clinical symptoms showed positive reactions to the mixed polyether impression materials, to the base paste or to a base paste component. The patient with the atypical clinical symptoms did not show any positive patch test reactions. Polyether impression materials may evoke type IV allergic reactions. The causative agent was a component of the base paste. In consideration of the widespread use of this impression material (millions of applications per year) and in comparison to the number of adverse reactions from other dental materials, the number of such allergic reactions is very low. In very scarce cases, positive allergic reactions to polyether impression materials are possible.

  19. Proximity to AGCT sequences dictates MMR-independent versus MMR-dependent mechanisms for AID-induced mutation via UNG2

    PubMed Central

    Thientosapol, Eddy Sanchai; Sharbeen, George; Lau, K.K. Edwin; Bosnjak, Daniel; Durack, Timothy; Stevanovski, Igor; Weninger, Wolfgang

    2017-01-01

    Abstract AID deaminates C to U in either strand of Ig genes, exclusively producing C:G/G:C to T:A/A:T transition mutations if U is left unrepaired. Error-prone processing by UNG2 or mismatch repair diversifies mutation, predominantly at C:G or A:T base pairs, respectively. Here, we show that transversions at C:G base pairs occur by two distinct processing pathways that are dictated by sequence context. Within and near AGCT mutation hotspots, transversion mutation at C:G was driven by UNG2 without requirement for mismatch repair. Deaminations in AGCT were refractive both to processing by UNG2 and to high-fidelity base excision repair (BER) downstream of UNG2, regardless of mismatch repair activity. We propose that AGCT sequences resist faithful BER because they bind BER-inhibitory protein(s) and/or because hemi-deaminated AGCT motifs innately form a BER-resistant DNA structure. Distal to AGCT sequences, transversions at G were largely co-dependent on UNG2 and mismatch repair. We propose that AGCT-distal transversions are produced when apyrimidinic sites are exposed in mismatch excision patches, because completion of mismatch repair would require bypass of these sites. PMID:28039326

  20. A unified view of base excision repair: lesion-dependent protein complexes regulated by post-translational modification

    PubMed Central

    Almeida, Karen H.; Sobol, Robert W.

    2007-01-01

    Base excision repair (BER) proteins act upon a significantly broad spectrum of DNA lesions that result from endogenous and exogenous sources. Multiple sub-pathways of BER (short-path or long-patch) and newly designated DNA repair pathways (e.g., SSBR and NIR) that utilize BER proteins complicate any comprehensive understanding of BER and its role in genome maintenance, chemotherapeutic response, neurodegeneration, cancer or aging. Herein, we propose a unified model of BER, comprised of three functional processes: Lesion Recognition/Strand Scission, Gap Tailoring and DNA Synthesis/Ligation, each represented by one or more multiprotein complexes and coordinated via the XRCC1/DNA Ligase III and PARP1 scaffold proteins. BER therefore may be represented by a series of repair complexes that assemble at the site of the DNA lesion and mediates repair in a coordinated fashion involving protein-protein interactions that dictate subsequent steps or sub-pathway choice. Complex formation is influenced by post-translational protein modifications that arise from the cellular state or the DNA damage response, providing an increase in specificity and efficiency to the BER pathway. In this review, we have summarized the reported BER protein-protein interactions and protein post-translational modifications and discuss the impact on DNA repair capacity and complex formation. PMID:17337257

  1. Fabrication of ordered arrays of micro- and nanoscale features with control over their shape and size via templated solid-state dewetting.

    PubMed

    Ye, Jongpil

    2015-05-08

    Templated solid-state dewetting of single-crystal films has been shown to be used to produce regular patterns of various shapes. However, the materials for which this patterning method is applicable, and the size range of the patterns produced are still limited. Here, it is shown that ordered arrays of micro- and nanoscale features can be produced with control over their shape and size via solid-state dewetting of patches patterned from single-crystal palladium and nickel films of different thicknesses and orientations. The shape and size characteristics of the patterns are found to be widely controllable with varying the shape, width, thickness, and orientation of the initial patches. The morphological evolution of the patches is also dependent on the film material, with different dewetting behaviors observed in palladium and nickel films. The mechanisms underlying the pattern formation are explained in terms of the influence on Rayleigh-like instability of the patch geometry and the surface energy anisotropy of the film material. This mechanistic understanding of pattern formation can be used to design patches for the precise fabrication of micro- and nanoscale structures with the desired shapes and feature sizes.

  2. Fabrication of ordered arrays of micro- and nanoscale features with control over their shape and size via templated solid-state dewetting

    PubMed Central

    Ye, Jongpil

    2015-01-01

    Templated solid-state dewetting of single-crystal films has been shown to be used to produce regular patterns of various shapes. However, the materials for which this patterning method is applicable, and the size range of the patterns produced are still limited. Here, it is shown that ordered arrays of micro- and nanoscale features can be produced with control over their shape and size via solid-state dewetting of patches patterned from single-crystal palladium and nickel films of different thicknesses and orientations. The shape and size characteristics of the patterns are found to be widely controllable with varying the shape, width, thickness, and orientation of the initial patches. The morphological evolution of the patches is also dependent on the film material, with different dewetting behaviors observed in palladium and nickel films. The mechanisms underlying the pattern formation are explained in terms of the influence on Rayleigh-like instability of the patch geometry and the surface energy anisotropy of the film material. This mechanistic understanding of pattern formation can be used to design patches for the precise fabrication of micro- and nanoscale structures with the desired shapes and feature sizes. PMID:25951816

  3. Laser welding versus suturing in tunica vaginalis and venous patch graft corporoplasty.

    PubMed

    Kirsch, A J; Chang, D T; Miller, M I; Connor, J P; Hensle, T W; Shabsigh, R

    1995-08-01

    Congenital penile curvature may result from corporeal disproportion in nearly 40% of cases, while in adults scarring of the corporeal bodies or periurethral fibrosis accounts for the majority of cases. Some surgeons advocate lengthening the fibrosed corporeal bodies by excising tunica albuginea and grafting such defects to straighten the penis. Tunica vaginalis, dermis, dorsal vein and lyophilized dura have been used for this purpose. Traditionally, these graft biomaterials have been sutured to the tunica albuginea. We assessed the feasibility, short-term safety and efficacy of diode laser tissue welding using albumin based solder and indocyanine green dye to perform patch graft corporoplasty in the dog. Ten animals were subjected to bilateral transverse excision of 1 x 2 cm. sections of tunica albuginea. Corporoplasty was performed using grafts composed of saphenous vein (5) or tunica vaginalis (5). Microsurgical repair with 7-zero polydioxanone suture (10) was compared to contralateral laser welded repair (10) by recording operative time, initial and short-term bursting pressures (mean plus or minus standard deviation) and histological analysis. Operative time on the laser side (9.8 +/- 2.3 minutes) was significantly shorter (p < 0.05) than on the suture side (17.1 +/- 5.1 minutes). Leak pressures, initially (laser 105.7 +/- 23.8 mm. Hg versus suture 35.3 +/- 8.0 mm. Hg), at 3 to 5 days (greater than 333.3 +/- 62.4 mm. Hg versus 136.6 +/- 39.4 mm. Hg) and at 7 to 10 days (greater than 397.8 +/- 39.8 mm. Hg versus 191.5 +/- 46.4 mm. Hg) were higher (p < 0.05) in the laser side compared to controls. Graft failure (necrosis) occurred in 3 repairs (2 laser on day 4 and 1 suture on day 10). Viable tissue with minimal differences in foreign body reaction between groups was observed in the remaining grafts. We conclude that laser welded patch graft corporoplasty using tunica vaginalis or vein is easy to perform, and provides excellent initial and short-term leak pressures. The use of laser welding in conjunction with suturing may be beneficial in corporoplasty for congenital or acquired penile curvature.

  4. Removal of N-6-methyladenine by the nucleotide excision repair pathway triggers the repair of mismatches in yeast gap-repair intermediates.

    PubMed

    Guo, Xiaoge; Jinks-Robertson, Sue

    2013-12-01

    Gap-repair assays have been an important tool for studying the genetic control of homologous recombination in yeast. Sequence analysis of recombination products derived when a gapped plasmid is diverged relative to the chromosomal repair template additionally has been used to infer structures of strand-exchange intermediates. In the absence of the canonical mismatch repair pathway, mismatches present in these intermediates are expected to persist and segregate at the next round of DNA replication. In a mismatch repair defective (mlh1Δ) background, however, we have observed that recombination-generated mismatches are often corrected to generate gene conversion or restoration events. In the analyses reported here, the source of the aberrant mismatch removal during gap repair was examined. We find that most mismatch removal is linked to the methylation status of the plasmid used in the gap-repair assay. Whereas more than half of Dam-methylated plasmids had patches of gene conversion and/or restoration interspersed with unrepaired mismatches, mismatch removal was observed in less than 10% of products obtained when un-methylated plasmids were used in transformation experiments. The methylation-linked removal of mismatches in recombination intermediates was due specifically to the nucleotide excision repair pathway, with such mismatch removal being partially counteracted by glycosylases of the base excision repair pathway. These data demonstrate that nucleotide excision repair activity is not limited to bulky, helix-distorting DNA lesions, but also targets removal of very modest perturbations in DNA structure. In addition to its effects on mismatch removal, methylation reduced the overall gap-repair efficiency, but this reduction was not affected by the status of excision repair pathways. Finally, gel purification of DNA prior to transformation reduced gap-repair efficiency four-fold in a nucleotide excision repair-defective background, indicating that the collateral introduction of UV damage can potentially compromise genetic interpretations. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Removal of N-6-methyladenine by the nucleotide excision repair pathway triggers the repair of mismatches in yeast gap-repair intermediates

    PubMed Central

    Guo, Xiaoge; Jinks-Robertson, Sue

    2013-01-01

    Gap-repair assays have been an important tool for studying the genetic control of homologous recombination in yeast. Sequence analysis of recombination products derived when a gapped plasmid is diverged relative to the chromosomal repair template additionally has been used to infer structures of strand-exchange intermediates. In the absence of the canonical mismatch repair pathway, mismatches present in these intermediates are expected to persist and segregate at the next round of DNA replication. In a mismatch repair defective (mlh1Δ) background, however, we have observed that recombination-generated mismatches are often corrected to generate gene conversion or restoration events. In the analyses reported here, the source of the aberrant mismatch removal during gap repair was examined. We find that most mismatch removal is linked to the methylation status of the plasmid used in the gap-repair assay. Whereas more than half of Dam-methylated plasmids had patches of gene conversion and/or restoration interspersed with unrepaired mismatches, mismatch removal was observed in less than 10% of products obtained when un-methylated plasmids were used in transformation experiments. The methylation-linked removal of mismatches in recombination intermediates was due specifically to the nucleotide excision repair pathway, with such mismatch removal being partially counteracted by glycosylases of the base excision repair pathway. These data demonstrate that nucleotide excision repair activity is not limited to bulky, helix-distorting DNA lesions, but also targets removal of very modest perturbations in DNA structure. In addition to its effects on mismatch removal, methylation reduced the overall gap-repair efficiency, but this reduction was not affected by the status of excision repair pathways. Finally, gel purification of DNA prior to transformation reduced gap-repair efficiency four-fold in a nucleotide excision repair-defective background, indicating that the cillateral introduction of UV damage can potentially compromise genetic interpretations. PMID:24120148

  6. Shear Bond Strength of Repair Systems to New CAD/CAM Restorative Materials.

    PubMed

    Üstün, Özlem; Büyükhatipoğlu, Işıl Keçik; Seçilmiş, Aslı

    2016-11-23

    To evaluate the bond strength of repair systems (Ceramic Repair, Clearfil Repair) to computer-aided design/computer-assisted machining (CAD/CAM) restorative materials (IPS e.max CAD, Vita Suprinity, Vita Enamic, Lava Ultimate). Thermally aged CAD/CAM restorative material specimens (5000 cycles between 5°C and 55°C) were randomly divided into two groups according to the repair system: Ceramic Repair (37% phosphoric acid + Monobond-S + Heliobond + Tetric N Ceram) or Clearfil Repair (40% phosphoric acid + mixture of Clearfil Porcelain Bond Activator and Clearfil SE Bond Primer + Clearfil SE Bond + Filtek Z250). The resin composite was light-cured on conditioned specimens. All specimens were stored in distilled water at 37°C for 24 hours and then additionally aged for 5000 thermal cycles. The shear bond strength test was performed using a universal testing machine (0.5 mm/min). Two-way ANOVA was used to detect significance differences according to the CAD/CAM material and composite repair system factors. Subgroup analyses were conducted using the least significant difference post-hoc test. The results of two-way ANOVA indicated that bond strength values varied according to the restorative materials (p < 0.05). No significant differences were observed between the CAD/CAM restorative materials (p > 0.05), except in the Vita Suprinity group (p < 0.05). Moreover, no differences were observed between the repair systems. Both the Clearfil and Ceramic repair systems used in the study allow for successful repairs. © 2016 by the American College of Prosthodontists.

  7. Mechanisms of double-strand-break repair during gene targeting in mammalian cells.

    PubMed Central

    Ng, P; Baker, M D

    1999-01-01

    In the present study, the mechanism of double-strand-break (DSB) repair during gene targeting at the chromosomal immunoglobulin mu-locus in a murine hybridoma was examined. The gene-targeting assay utilized specially designed insertion vectors genetically marked in the region of homology to the chromosomal mu-locus by six diagnostic restriction enzyme site markers. The restriction enzyme markers permitted the contribution of vector-borne and chromosomal mu-sequences in the recombinant product to be determined. The use of the insertion vectors in conjunction with a plating procedure in which individual integrative homologous recombination events were retained for analysis revealed several important features about the mammalian DSB repair process:The presence of the markers within the region of shared homology did not affect the efficiency of gene targeting.In the majority of recombinants, the vector-borne marker proximal to the DSB was absent, being replaced with the corresponding chromosomal restriction enzyme site. This result is consistent with either formation and repair of a vector-borne gap or an "end" bias in mismatch repair of heteroduplex DNA (hDNA) that favored the chromosomal sequence. Formation of hDNA was frequently associated with gene targeting and, in most cases, began approximately 645 bp from the DSB and could encompass a distance of at least 1469 bp.The hDNA was efficiently repaired prior to DNA replication.The repair of adjacent mismatches in hDNA occurred predominantly on the same strand, suggesting the involvement of a long-patch repair mechanism. PMID:10049929

  8. Lectin-based food poisoning: a new mechanism of protein toxicity.

    PubMed

    Miyake, Katsuya; Tanaka, Toru; McNeil, Paul L

    2007-08-01

    Ingestion of the lectins present in certain improperly cooked vegetables can result in acute GI tract distress, but the mechanism of toxicity is unknown. In vivo, gut epithelial cells are constantly exposed to mechanical and other stresses and consequently individual cells frequently experience plasma membrane disruptions. Repair of these cell surface disruptions allows the wounded cell to survive: failure results in necrotic cell death. Plasma membrane repair is mediated, in part, by an exocytotic event that adds a patch of internal membrane to the defect site. Lectins are known to inhibit exocytosis. We therefore tested the novel hypothesis that lectin toxicity is due to an inhibitory effect on plasma membrane repair. Repair of plasma membrane disruptions and exocytosis of mucus was assessed after treatment of cultured cell models and excised segments of the GI tract with lectins. Plasma membrane disruptions were produced by focal irradiation of individual cells, using a microscope-based laser, or by mechanical abrasion of multiple cells, using a syringe needle. Repair was then assessed by monitoring the cytosolic penetration of dyes incapable of crossing the intact plasma membrane. We found that cell surface-bound lectins potently inhibited plasma membrane repair, and the exocytosis of mucus that normally accompanies the repair response. Lectins potently inhibit plasma membrane repair, and hence are toxic to wounded cells. This represents a novel form of protein-based toxicity, one that, we propose, is the basis of plant lectin food poisoning.

  9. Pulmonary annulus growth after the modified Blalock-Taussig shunt in tetralogy of Fallot.

    PubMed

    Nakashima, Kouki; Itatani, Keiichi; Oka, Norihiko; Kitamura, Tadashi; Horai, Tetsuya; Hari, Yosuke; Miyaji, Kagami

    2014-09-01

    In tetralogy of Fallot (TOF), it is well known that postoperative pulmonary regurgitation reduces right ventricular function during long-term follow-up. Complete repair without a transannular patch should help avoid pulmonary regurgitation. Recently, primary complete repair has been preferred to the staged repair with use of a Blalock-Taussig shunt (BTS) even in neonates or small infants; however, little has been reported about the influence of a BTS on pulmonary annular growth. We examined 40 patients with TOF or double-outlet right ventricle with pulmonary stenosis. Twenty-one patients received a BTS before complete repair, whereas 19 patients underwent primary complete repair. Pulmonary annular size was measured by echocardiography before BTS, complete repair, or both, and ventricular volume was measured by cardiac catheterization. There were no significant differences in complete repair age or body size between the groups. Pulmonary annulus sizes in the BTS group were smaller than those in the primary repair group (Z score, -5.1 ± 2.5 vs -3.7 ± 1.8). After the BTS, significant annular growth (Z score, -2.8 ± 2.1) was observed (p = 0.0028), with a significant increase in left ventricular end-diastolic volume (p = 0.015). When patients with severe pulmonary stenosis (Z score > -7.0) were excluded, pulmonary annular preservation at complete repair was achieved in 64.7% (11/17) of the BTS group and 36.8% (7/19) of the primary repair group (p = 0.088). The BTS increased the pulmonary annular size and the left ventricular volume during the 6 months before complete repair, resulting in preservation of the pulmonary valve function. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  10. Optimal Location of Piezoelectric Patch on Composite Structure using Viewing Method

    NASA Astrophysics Data System (ADS)

    Samyal, Rahul; Bagha, Ashok K.

    2017-08-01

    A useful material which is manufactured by mixing of two or three different materials in homogeneous level is termed as composite material. In now day’s composite materials are used in wide area such as aerospace, automobiles, satellite, bullet proof jackets, rotor blades etc. In this paper modal analysis of composite material, mixture of polyester as matrix and glass as fiber, is carried out by using ABAQUS software. The modal analysis of composite material for fiber orientation 450 is carried out. In this paper by viewing the different mode shapes of the composite material, the optimal location of piezoelectric patch is carried out.

  11. Inspection Guide for Reinforced Concrete Vessels. Volume 2. Commentary

    DTIC Science & Technology

    1981-10-01

    situ testing of hardened concrete; and guidelines for inspection. < The material is designed for use by the U.S. Coast Guard Marine Inspector. It...Durability Tests 96 10.7 Other Tests 99 11. REPAIRS 102 11.1 Evaluation for Repair L02 11.2 Repair Materials 103 11.3 Repair of Cracks 104 11.4 Repair of...Cement 36 8 Characteristics and Tests of Aggregates 38 9 Tests for Deleterious Materials in Aggregates 39 10 Classification of Admixtures 43 11

  12. Mechanical Development of a Very Non-Standard Patch Array Antenna for Extreme Environments

    NASA Technical Reports Server (NTRS)

    Hughes, Richard; Chamberlain, Neil; Jakoboski, Julie; Petkov, Mihail

    2012-01-01

    This paper describes the mechanical development of patch antenna arrays for the Juno mission. The patch arrays are part of a six-frequency microwave radiometer instrument that will be used to measure thermal emissions from Jupiter. The very harsh environmental conditions in Jupiter orbit, as well as a demanding launch environment, resulted in a design that departs radically from conventional printed circuit patch antennas. The paper discusses the development and qualification of the Juno patch array antennas, with emphasis on the materials approach that was devised to mitigate the effects of electron charging in Jupiter orbit.

  13. Long-term monitoring of mechanical properties of FRP repair materials.

    DOT National Transportation Integrated Search

    2013-07-01

    Fiber- reinforced polymer composites (FRP) are an attractive repair option for existing concrete structures. : CDOT has used this material on some projects, in particular the repair of the Castlewood Canyon Bridge in : 2003. Further use of the materi...

  14. Dental materials for cleft palate repair.

    PubMed

    Sharif, Faiza; Ur Rehman, Ihtesham; Muhammad, Nawshad; MacNeil, Sheila

    2016-04-01

    Numerous bone and soft tissue grafting techniques are followed to repair cleft of lip and palate (CLP) defects. In addition to the gold standard surgical interventions involving the use of autogenous grafts, various allogenic and xenogenic graft materials are available for bone regeneration. In an attempt to discover minimally invasive and cost effective treatments for cleft repair, an exceptional growth in synthetic biomedical graft materials have occurred. This study gives an overview of the use of dental materials to repair cleft of lip and palate (CLP). The eligibility criteria for this review were case studies, clinical trials and retrospective studies on the use of various types of dental materials in surgical repair of cleft palate defects. Any data available on the surgical interventions to repair alveolar or palatal cleft, with natural or synthetic graft materials was included in this review. Those datasets with long term clinical follow-up results were referred to as particularly relevant. The results provide encouraging evidence in favor of dental and other related biomedical materials to fill the gaps in clefts of lip and palate. The review presents the various bones and soft tissue replacement strategies currently used, tested or explored for the repair of cleft defects. There was little available data on the use of synthetic materials in cleft repair which was a limitation of this study. In conclusion although clinical trials on the use of synthetic materials are currently underway the uses of autologous implants are the preferred treatment methods to date. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Investigation on Failures of Composite Beam and Substrate Concrete due to Drying Shrinkage Property of Repair Materials

    NASA Astrophysics Data System (ADS)

    Pattnaik, Rashmi Ranjan

    2017-06-01

    A Finite Element Analysis (FEA) and an experimental study was conducted on composite beam of repair material and substrate concrete to investigate the failures of the composite beam due to drying shrinkage property of the repair materials. In FEA, the stress distribution in the composite beam due to two concentrate load and shrinkage of repair materials were investigated in addition to the deflected shape of the composite beam. The stress distributions and load deflection shapes of the finite element model were investigated to aid in analysis of the experimental findings. In the experimental findings, the mechanical properties such as compressive strength, split tensile strength, flexural strength, and load-deflection curves were studied in addition to slant shear bond strength, drying shrinkage and failure patterns of the composite beam specimens. Flexure test was conducted to simulate tensile stress at the interface between the repair material and substrate concrete. The results of FEA were used to analyze the experimental results. It was observed that the repair materials with low drying shrinkage are showing compatible failure in the flexure test of the composite beam and deform adequately in the load deflection curves. Also, the flexural strength of the composite beam with low drying shrinkage repair materials showed higher flexural strength as compared to the composite beams with higher drying shrinkage value of the repair materials even though the strength of those materials were more.

  16. Miniaturized dual band multislotted patch antenna on polytetrafluoroethylene glass microfiber reinforced for C/X band applications.

    PubMed

    Islam, M T; Samsuzzaman, M

    2014-01-01

    This paper introduces a new configuration of compact, triangular- and diamond-slotted, microstrip-fed, low-profile antenna for C/X band applications on polytetrafluoroethylene glass microfiber reinforced material substrate. The antenna is composed of a rectangular-shaped patch containing eight triangles and two diamond-shaped slots and an elliptical-slotted ground plane. The rectangular-shaped patch is obtained by cutting two diamond slots in the middle of the rectangular patch, six triangular slots on the left and right side of the patch, and two triangular slots on the up and down side of the patch. The slotted radiating patch, the elliptical-slotted ground plane, and the microstrip feed enable the matching bandwidth to be widened. A prototype of the optimized antenna was fabricated on polytetrafluoroethylene glass microfiber reinforced material substrate using LPKF prototyping machine and investigated to validate the proposed design. The simulated results are compared with the measured data, and good agreement is achieved. The proposed antenna offers fractional bandwidths of 13.69% (7.78-8.91 GHz) and 10.35% (9.16-10.19 GHz) where S11 < -10 dB at center frequencies of 8.25 GHz and 9.95 GHz, respectively, and relatively stable gain, good radiation efficiency, and omnidirectional radiation patterns in the matching band.

  17. Surgical results and protocols in the spectrum of tetralogy of Fallot.

    PubMed Central

    Kirklin, J W; Blackstone, E H; Kirklin, J K; Pacifico, A D; Aramendi, J; Bargeron, L M

    1983-01-01

    Between 1967 and July 1982, 1103 operations were performed for the tetralogy of Fallot of all types with 116 (10.5%) hospital deaths. Eighty-eight hospital deaths (10.5%) occurred in the 836 patients undergoing repair. The incremental risk factors for hospital death after repair include pulmonary arterial problems (p = 0.0002), major associated cardiac anomalies (p less than 0.0001), small size (young age) (p less than 0.0001), and more than one previous operation (p = 0.0004). Absent pulmonary valve is a risk factor (p = 0.04). In patients with pulmonary stenosis, the hospital mortality has decreased with time (p = 0.08), but the incremental risk of a high hematocrit (p = 0.0003) and of transannular patching (p = 0.05) has persisted. In the current era, the risk of repair in patients with pulmonary stenosis is estimated to be 1.6% (70% confidence limits [CL] 0.7% to 3.5%) at age 5 years, and at age 12 months to be 4.1% (CL 2.7% to 6.3%) without a transannular patch and 7.7% (CL a5.3% to 11%) with one. When pulmonary atresia is present, the probability of hospital death after repair when a valved extracardiac conduit is used is estimated to be lowest (5%; CL 2% to 8%) between 5 1/2 and 16 years of age. No deaths occurred among 53 patients with pulmonary stenosis receiving a primary palliative Blalock-Taussig or Gore-Tex shunt, and six deaths (12%) occurred in 51 patients with pulmonary atresia. Serious interim complications (sudden death, brain abscess) after these shunts occurred in two (1.9%; CL 0.6% to 4.5%) of the patients operated on. No iatrogenic pulmonary arterial problems have been recognized. Protocols based on these results are presented. Many of these selective recommendations may become unnecessary if the damaging effects of cardiopulmonary bypass are overcome by future research. Images Fig. 2. Fig. 3. PMID:6615049

  18. Glaucoma aqueous drainage device erosion repair with buccal mucous membrane grafts.

    PubMed

    Rootman, Dan B; Trope, Graham E; Rootman, David S

    2009-01-01

    Glaucoma aqueous drainage devices are important and effective in the management of recalcitrant glaucoma. One complication of this procedure is erosion and exposure of the tube or plate. Strategies to re-cover glaucoma aqueous drainage devices in such cases have met with variable success. The majority of these interventions use conjunctiva for superficial coverage. However, conjunctiva can be in limited supply, and subject to reerosion. In this report, we discuss the use of oral buccal mucous membrane in combination with a lamellar corneal patch graft for repair of 3 exposed tubes, 2 plates, and a pars plana clip. Mean time to exposure was 4.8 years. Five eyes from 4 patients are presented and the surgical technique is described. Buccal membrane repairs were considered a surgical success in 5 out of 6 cases (83%) with mean follow-up of 1.5 years. We advocate the use of buccal membrane in the repair of glaucoma aqueous drainage device tube/plate erosions in patients for whom local conjunctiva is of variable quality or limited supply. Advantages of this procedure and tissue option are discussed.

  19. Iatrogenic Diversion of Inferior Vena Cava into Left Atrium after Surgery for a Rare Combination of Congenital Heart Diseases

    PubMed Central

    Sabzi, Feridoun

    2016-01-01

    Atrial septal defect (ASD) is a common congenital anomaly that has low surgical mortality and morbidity. We report a very rare case of a low-lying ASD, combined with the drainage of the inferior vena cava and the left superior vena cava into the left atrium. This combination was associated with an unroofed coronary sinus. We also describe an iatrogenic surgical diversion of the inferior vena cava into the left atrium with its complication. The patient presented with moderate cyanosis and was referred for elective ASD repair. He underwent surgical repair of the ASD after transthoracic echocardiography. Early postoperative right-to-left shunting with cyanosis and hypoxia was associated with abdominal complications. Surgical re-exploration revealed the diversion of the inferior vena cava into the left atrium, which was repaired with a pericardial patch. Peptic ulcer perforation was repaired after abdominal laparotomy. The patient had an uneventful recovery and was discharged home on the 17th postoperative day. One-year follow-up revealed no recurrence of cyanosis or residual ASD on echocardiography. PMID:27928261

  20. [Treatment of Fallot tetralogy with a transannular patch. Six years follow-up].

    PubMed

    Galicia-Tornell, Myriam; Reyes-López, Alfonso; Ruíz-González, Sergio; Bolio-Cerdán, Alejandro; González-Ojeda, Alejandro; Fuentes-Orozco, Clotilde

    2015-01-01

    Primary repair of Fallot tetralogy has been performed successfully for the last 45 years. It has low surgical mortality (< 5%), with excellent long-term results. However, there are delayed adverse effects: progressive right ventricular dilation and dysfunction, arrhythmia, and sudden death. In our centre, Fallot tetralogy is the most common form of cyanotic congenital heart disease (including transannular patch) and accounts for 7.5% of all cardiovascular surgical procedures. The mid-term follow-up results are reported. Case series. The study included patients who had complete repair of Fallot tetralogy with transannular patch from January 2000 to December 2009. An analysis was performed on the clinical variables, morbidity and mortality. There were 52 patients in the study, with mean age 4 ± 2 years. Perioperative mortality in 6 patients, with 5 associated with residual right ventricular obstruction and, 1 associated with further surgery. The survival rate was 88% (46) patients, with a follow-up 75 ± 26 months. Late morbidity occurred in 14, due to right ventricular dysfunction in 11, recurrent distal obstruction in 2, and residual ventricular septal defect in 1. Associated risk factors were severe pulmonary insufficiency (p=0.001); QRS > 160 ms, p=0.001); cardiothoracic > 0.60 index, (p=0.048), and tricuspid regurgitation (p=0.001). There was reasonable long-term survival and excellent quality of life after total correction of Fallot tetralogy; however, progressive right ventricular dysfunction requires continuous monitoring, as well as the choice of optimal timing of pulmonary valve replacement. Copyright © 2015 Academia Mexicana de Cirugía A.C. Published by Masson Doyma México S.A. All rights reserved.

  1. Thermal protection system repair kit program

    NASA Technical Reports Server (NTRS)

    1979-01-01

    The feasibility and conceptual design aspects of repair materials and procedures for in orbit repair of the space shuttle orbiter TPS tiles are investigated. Material studies to investigate cure in place materials are described including catalyst and cure studies, ablation tests and evaluations, and support mixing and applicator design. The feasibility of the repair procedures, the storage of the TPS, dispensing, and cure problems are addressed.

  2. Resistively Loaded Microstrip-Patch Antenna

    NASA Technical Reports Server (NTRS)

    Bailey, Marion C.

    1993-01-01

    Strips of thin resistive material added near two edges of conventional micro-strip-patch antenna. Bandwidth doubled by simple modification. Optimum bandwidth performance obtained by adjustment of shapes, resistances, and locations of resistive strips.

  3. The modeling of piezoceramic patch interactions with shells, plates and beams

    NASA Technical Reports Server (NTRS)

    Banks, H. T.; Smith, R. C.

    1992-01-01

    General models describing the interactions between a pair of piezoceramic patches and elastic substructures consisting of a cylindrical shell, plate and beam are presented. In each case, the manner in which the patch loads enter both the strong and weak forms of the time-dependent structural equations of motion is described. Through force and moment balancing, these loads are then determined in terms of material properties of the patch and substructure (thickness, elastic properties, Poisson ratios), the geometry of the patch placement, and the voltages into the patches. In the case of the shell, the coupling between banding and inplane deformations, which is due to the curvature, is retained. These models are sufficiently general to allow for potentially different patch voltages which implies that they can be suitably employed when using piezoceramic patches for controlling system dynamics when both extensional and bending vibrations are present.

  4. Biodegradable Magnesium Alloys Developed as Bone Repair Materials: A Review

    PubMed Central

    Liu, Chen; Ren, Zheng; Xu, Yongdong; Pang, Song; Zhao, Xinbing

    2018-01-01

    Bone repair materials are rapidly becoming a hot topic in the field of biomedical materials due to being an important means of repairing human bony deficiencies and replacing hard tissue. Magnesium (Mg) alloys are potentially biocompatible, osteoconductive, and biodegradable metallic materials that can be used in bone repair due to their in situ degradation in the body, mechanical properties similar to those of bones, and ability to positively stimulate the formation of new bones. However, rapid degradation of these materials in physiological environments may lead to gas cavities, hemolysis, and osteolysis and thus, hinder their clinical orthopedic applications. This paper reviews recent work on the use of Mg alloy implants in bone repair. Research to date on alloy design, surface modification, and biological performance of Mg alloys is comprehensively summarized. Future challenges for and developments in biomedical Mg alloys for use in bone repair are also discussed. PMID:29725492

  5. Surgical repair and postoperative course of an infant with infracardiac total anomalous pulmonary venous connection, cor triatriatum sinistrum and transposition of the great arteries.

    PubMed

    Thies, W R; Matthies, W; Minami, K; Pott, U; Meyer, H; Körfer, R

    1990-01-01

    The combination of a d-transposition of the great arteries, cor triatriatum sinistrum and a total anomalous pulmonary venous connection of the infracardiac type is a very rare condition. Up to now, one surgical repair in an adolescent with transposed great arteries and total anomalous pulmonary venous drainage of the supracardiac type has been reported. In this paper, an infant with the above mentioned cardiovascular malformation is presented. The common pulmonary vein drained into the inferior vena cava and was obstructed. There were arborisation abnormalities in both lungs with mild pulmonary hypertension. The infant has been successfully operated upon at the age of 6 months and a weight of 4.5 kg. The membrane within the left atrium was resected, the common pulmonary vein was anastomosed to the left atrium and a Mustard procedure was performed. During the first 6 postoperative weeks, the infant had problems with adaptation. There was both a transient ballooning of the Mustard patch with significant obstruction of the pulmonary venous drainage and a delayed pulmonary recovery. Two months later, the patch was straightened and the child could be discharged from hospital. After 12 months, the child died from an infection of the airways.

  6. Management and outcomes of scoliosis in children with congenital diaphragmatic hernia.

    PubMed

    Antiel, Ryan M; Riley, John S; Cahill, Patrick J; Campbell, Robert M; Waqar, Lindsay; Herkert, Lisa M; Rintoul, Natalie E; Peranteau, William H; Flake, Alan W; Adzick, N Scott; Hedrick, Holly L

    2016-12-01

    The purpose of this study was to evaluate the management and outcomes of CDH patients with scoliosis. From January 1996 to August 2015, 26 of 380 (7%) CDH patients were diagnosed with scoliosis. Six (23%) were prenatally diagnosed by ultrasound, and 9 (35%) were diagnosed postnatally. The remaining 11 (42%) developed scoliosis after discharge. Mean follow-up was 6.6years. Among the 15 patients with congenital scoliosis, there were 2 (13%) perinatal deaths. Five of the 13 (38%) survivors required orthopedic surgery, and 2 have required bracing. The mean age at initial surgery was 7years. These five children underwent an average of 2.8 (range 1-7) expansions or revisions. All surgical patients required supplemental oxygen at 28days of life, and 1 required a tracheostomy. None of the 11 patients who developed scoliosis later in life required surgery, but 3 have required bracing. Six of the 11 (55%) required a patch repair for CDH compared to 158 of 264 (60%) CDH patients without scoliosis (p=0.73). Early diagnosis of scoliosis in CDH patients is associated with a high rate of surgery. There was not a higher incidence of patch repair among patients who developed scoliosis. Prognosis. Retrospective study, level II. Copyright © 2016. Published by Elsevier Inc.

  7. Recent progress in injectable bone repair materials research

    NASA Astrophysics Data System (ADS)

    Chen, Zonggang; Zhang, Xiuli; Kang, Lingzhi; Xu, Fei; Wang, Zhaoling; Cui, Fu-Zhai; Guo, Zhongwu

    2015-12-01

    Minimally invasive injectable self-setting materials are useful for bone repairs and for bone tissue regeneration in situ. Due to the potential advantages of these materials, such as causing minimal tissue injury, nearly no influence on blood supply, easy operation and negligible postoperative pain, they have shown great promises and successes in clinical applications. It has been proposed that an ideal injectable bone repair material should have features similar to that of natural bones, in terms of both the microstructure and the composition, so that it not only provides adequate stimulus to facilitate cell adhesion, proliferation and differentiation but also offers a satisfactory biological environment for new bone to grow at the implantation site. This article reviews the properties and applications of injectable bone repair materials, including those that are based on natural and synthetic polymers, calcium phosphate, calcium phosphate/polymer composites and calcium sulfate, to orthopedics and bone tissue repairs, as well as the progress made in biomimetic fabrication of injectable bone repair materials.

  8. Salvage hypospadias repairs

    PubMed Central

    Sripathi, V.; Satheesh, M.; Shubha, K.

    2008-01-01

    Aim: Review of our experience and to develop an algorithm for salvage procedures in the management of hypospadias cripples and treatment of urethral strictures following hypospadias repair. Methods: This is a retrospective review of hypospadias surgeries over a 41-month period. Out of a total 168 surgeries, 20 were salvage/re-operative repairs. In three children a Duplay repair was feasible, while in four others a variety of single-stage repairs could be done. The repair was staged in seven children – buccal mucosal grafts (BMGs) in five, buccal mucosal tube in one, and skin graft in one. Five children with dense strictures were managed by dorsal BMG inlay grafting in one, vascularized tunical onlay grafting on the ventrum in one, and a free tunical patch in one. Three children were treated by internal urethrotomy and stenting for four weeks with a poor outcome. Results: The age of children ranged from 1.5–15 years (mean 4.5). Follow-up ranged from 3 months to 3.5 years. Excellent results were obtained in 10 children (50%) with a well-surfaced erect penis and a slit-like meatus. Glans closure could not be achieved and meatus was coronal in three. Two children developed fistulae following a Duplay repair and following a staged BMG. Three repairs failed completely – a composite repair broke down, a BMG tube stenosed with a proximal leak, and a stricture recurred with loss of a ventral free tunical graft. Conclusions: In salvage procedures performed on hypospadias cripples, a staged repair with buccal mucosa as an inlay in the first stage followed by tubularization 4–6 months later provides good results. A simple algorithm to plan corrective surgery in failed hypospadias cases and obtain satisfactory results is devised. PMID:20011495

  9. Salvage hypospadias repairs.

    PubMed

    Sripathi, V; Satheesh, M; Shubha, K

    2008-10-01

    Review of our experience and to develop an algorithm for salvage procedures in the management of hypospadias cripples and treatment of urethral strictures following hypospadias repair. This is a retrospective review of hypospadias surgeries over a 41-month period. Out of a total 168 surgeries, 20 were salvage/re-operative repairs. In three children a Duplay repair was feasible, while in four others a variety of single-stage repairs could be done. The repair was staged in seven children - buccal mucosal grafts (BMGs) in five, buccal mucosal tube in one, and skin graft in one. Five children with dense strictures were managed by dorsal BMG inlay grafting in one, vascularized tunical onlay grafting on the ventrum in one, and a free tunical patch in one. Three children were treated by internal urethrotomy and stenting for four weeks with a poor outcome. The age of children ranged from 1.5-15 years (mean 4.5). Follow-up ranged from 3 months to 3.5 years. Excellent results were obtained in 10 children (50%) with a well-surfaced erect penis and a slit-like meatus. Glans closure could not be achieved and meatus was coronal in three. Two children developed fistulae following a Duplay repair and following a staged BMG. Three repairs failed completely - a composite repair broke down, a BMG tube stenosed with a proximal leak, and a stricture recurred with loss of a ventral free tunical graft. In salvage procedures performed on hypospadias cripples, a staged repair with buccal mucosa as an inlay in the first stage followed by tubularization 4-6 months later provides good results. A simple algorithm to plan corrective surgery in failed hypospadias cases and obtain satisfactory results is devised.

  10. Patching the Exchange-Correlation Potential in Density Functional Theory.

    PubMed

    Huang, Chen

    2016-05-10

    A method for directly patching exchange-correlation (XC) potentials in materials is derived. The electron density of a system is partitioned into subsystem densities by dividing its Kohn-Sham (KS) potential among the subsystems. Inside each subsystem, its projected KS potential is required to become the total system's KS potential. This requirement, together with the nearsightedness principle of electronic matters, ensures that the electronic structures inside subsystems can be good approximations to the total system's electronic structure. The nearsightedness principle also ensures that subsystem densities could be well localized in their regions, making it possible to use high-level methods to invert the XC potentials for subsystem densities. Two XC patching methods are developed. In the local XC patching method, the total system's XC potential is improved in the cluster region. We show that the coupling between a cluster and its environment is important for achieving a fast convergence of the electronic structure in the cluster region. In the global XC patching method, we discuss how to patch the subsystem XC potentials to construct the XC potential in the total system, aiming to scale up high-level quantum mechanics simulations of materials. Proof-of-principle examples are given.

  11. Review of Repair Materials for Fire-Damaged Reinforced Concrete Structures

    NASA Astrophysics Data System (ADS)

    Zahid, MZA Mohd; Abu Bakar, BH; Nazri, FM; Ahmad, MM; Muhamad, K.

    2018-03-01

    Reinforced concrete (RC) structures perform well during fire and may be repaired after the fire incident because their low heat conductivity prevents the loss or degradation of mechanical strength of the concrete core and internal reinforcing steel. When an RC structure is heated to more than 500 °C, mechanical properties such as compressive strength, stiffness, and tensile strength start to degrade and deformations occur. Although the fire-exposed RC structure shows no visible damage, its residual strength decreases compared with that in the pre-fire state. Upon thorough assessment, the fire-damaged RC structure can be repaired or strengthened, instead of subjecting to partial or total demolition followed by reconstruction. The structure can be repaired using several materials, such as carbon fiber-reinforced polymer, glass fiber-reinforced polymer, normal strength concrete, fiber-reinforced concrete, ferrocement, epoxy resin mortar, and high-performance concrete. Selecting an appropriate repair material that must be compatible with the substrate or base material is a vital step to ensure successful repair. This paper reviews existing repair materials and factors affecting their performance. Of the materials considered, ultra-high-performance fiber-reinforced concrete (UHPFRC) exhibits huge potential for repairing fire-damaged RC structures but lack of information available. Hence, further studies must be performed to assess the potential of UHPFRC in rehabilitating fire-damaged RC structures.

  12. Influence of different repair procedures on bond strength of adhesive filling materials to etched enamel in vitro.

    PubMed

    Hannig, Christian; Hahn, Petra; Thiele, Patrick-Philipp; Attin, Thomas

    2003-01-01

    Contamination of etched enamel with repair bond agents during repair of dental restorations may interfere with the bonding of composite to enamel. This study examined the bond strength of adhesive filling materials to etched bovine enamel after pre-treatment with the repair systems Monobond S, Silibond and Co-Jet. The materials Tetric Ceram, Dyract and Definite and their corresponding bonding agents (Syntac Single Comp, Prime & Bond NT, Etch and Prime) were tested in combination with the repair systems. One hundred and thirty-five enamel specimens were etched (37% phosphoric acid, 60 seconds) and equally distributed among three groups (A-C). In Group A, the repair materials were applied on etched enamel followed by applying the composite materials without using their respective bonding material. In Group B, the composite materials were placed on etched enamel after applying the repair materials and bonding agents. In control Group C, the composite materials and bonding agents were applied on etched enamel without using the repair systems. In each sub-group, every composite material was applied on 15 specimens. Samples were stored in artificial saliva for 14 days and thermocycled 1,000 times (5 degrees C/55 degrees C). The shear bond strength of the samples were then determined in a universal testing machine (ISO 10477). Applying Monobond or Silibond followed by the use of its respective bonding agents resulted in a bond strength that was not statistically different from the controls for all filling materials (Group C). The three composites that used Monobond and Silibond without applying the corresponding bonding agent resulted in bond strengths that were significantly lower than the controls. Utilizing the Co-Jet-System drastically reduced the bond strength of composites on etched enamel. Contamination of etched enamel with the repairing bonding agents Monobond and Silibond does not interfere with bond strength if the application of Monobond and Silibond is followed by using its corresponding bonding system of the composites tested.

  13. Creep Forming of Carbon-Reinforced Ceramic-Matrix Composites

    NASA Technical Reports Server (NTRS)

    Vaughn, Wallace L.; Scotti, Stephan J.; Ashe, Melissa P.; Connolly, Liz

    2007-01-01

    A set of lecture slides describes an investigation of creep forming as a means of imparting desired curvatures to initially flat stock plates of carbon-reinforced ceramic-matrix composite (C-CMC) materials. The investigation is apparently part of a continuing effort to develop improved means of applying small CCMC repair patches to reinforced carbon-carbon leading edges of aerospace vehicles (e.g., space shuttles) prior to re-entry into the atmosphere of the Earth. According to one of the slides, creep forming would be an intermediate step in a process that would yield a fully densified, finished C-CMC part having a desired size and shape (the other steps would include preliminary machining, finish machining, densification by chemical vapor infiltration, and final coating). The investigation included experiments in which C-CMC disks were creep-formed by heating them to unspecified high temperatures for time intervals of the order of 1 hour while they were clamped into single- and double-curvature graphite molds. The creep-formed disks were coated with an oxidation- protection material, then subjected to arc-jet tests, in which the disks exhibited no deterioration after exposure to high-temperature test conditions lasting 490 seconds.

  14. Self-Healing Wire Insulation

    NASA Technical Reports Server (NTRS)

    Parrish, Clyde F. (Inventor)

    2012-01-01

    A self-healing system for an insulation material initiates a self-repair process by rupturing a plurality of microcapsules disposed on the insulation material. When the plurality of microcapsules are ruptured, reactants within the plurality of microcapsules react to form a replacement polymer in a break of the insulation material. This self-healing system has the ability to repair multiple breaks in a length of insulation material without exhausting the repair properties of the material.

  15. The use of biological grafts for reconstruction of the inferior vena cava is a safe and valid alternative: results in 32 patients in a single institution

    PubMed Central

    Pulitanó, Carlo; Crawford, Michael; Ho, Phong; Gallagher, James; Joseph, David; Stephen, Michael; Sandroussi, Charbel

    2013-01-01

    Background Resection and reconstruction of the inferior vena cava (IVC) is occasionally required in the surgical treatment of intra-abdominal tumours. IVC reconstruction can be performed with biological or synthetic graft material, with most centres preferring synthetic grafts. In spite of the potential advantages of biological grafts in terms of handling characteristics, and safety, very limited data are available about their use in patients requiring an IVC resection. Methods Medical records of 32 patients who underwent an IVC resection and reconstruction from 1990 and 2011 with autogenous peritoneo-fascial (N = 22) and bovine pericardial (N = 10) grafts were reviewed. Results A tangential resection with patch repair was performed in 10 patients, whereas in the remaining 22 it was necessary to resect and replace a segment or all of the retrohepatic IVC. A concomitant liver resection was performed in 14 patients, nephrectomy in 10 and pancreaticoduodenectomy in 2 patients. There were no acute or late complications related to graft thrombosis or infection. Three patients died as a consequence of multi-organ failure. Overall survival at 1 and 5 years was 78% and 48%, respectively. Conclusions The preferential use of synthetic grafts in IVC replacement is not evidence based. Selection of an appropriate prosthetic graft for IVC reconstruction should be based on the safety and its handling features. The use of biological grafts for IVC repair is a valid alternative to current synthetic materials and may in fact be superior in terms of biocompatability, ease of handling, reduced rate of infection and improved long-term patency without permanent anticoagulation. PMID:23458108

  16. The use of biological grafts for reconstruction of the inferior vena cava is a safe and valid alternative: results in 32 patients in a single institution.

    PubMed

    Pulitanó, Carlo; Crawford, Michael; Ho, Phong; Gallagher, James; Joseph, David; Stephen, Michael; Sandroussi, Charbel

    2013-08-01

    Resection and reconstruction of the inferior vena cava (IVC) is occasionally required in the surgical treatment of intra-abdominal tumours. IVC reconstruction can be performed with biological or synthetic graft material, with most centres preferring synthetic grafts. In spite of the potential advantages of biological grafts in terms of handling characteristics, and safety, very limited data are available about their use in patients requiring an IVC resection. Medical records of 32 patients who underwent an IVC resection and reconstruction from 1990 and 2011 with autogenous peritoneo-fascial (N = 22) and bovine pericardial (N = 10) grafts were reviewed. A tangential resection with patch repair was performed in 10 patients, whereas in the remaining 22 it was necessary to resect and replace a segment or all of the retrohepatic IVC. A concomitant liver resection was performed in 14 patients, nephrectomy in 10 and pancreaticoduodenectomy in 2 patients. There were no acute or late complications related to graft thrombosis or infection. Three patients died as a consequence of multi-organ failure. Overall survival at 1 and 5 years was 78% and 48%, respectively. The preferential use of synthetic grafts in IVC replacement is not evidence based. Selection of an appropriate prosthetic graft for IVC reconstruction should be based on the safety and its handling features. The use of biological grafts for IVC repair is a valid alternative to current synthetic materials and may in fact be superior in terms of biocompatability, ease of handling, reduced rate of infection and improved long-term patency without permanent anticoagulation. © 2013 International Hepato-Pancreato-Biliary Association.

  17. Tissue expander-stimulated lengthening of arteries for the treatment of midaortic syndrome in children.

    PubMed

    Kim, Heung Bae; Vakili, Khashayar; Ramos-Gonzalez, Gabriel J; Stein, Deborah R; Ferguson, Michael A; Porras, Diego; Lock, James E; Chaudry, Gulraiz; Alomari, Ahmad; Fishman, Steven J

    2018-01-17

    Midaortic syndrome (MAS) is a rare condition characterized by stenosis of the abdominal aorta. Patients with disease refractory to medical management will usually require either endovascular therapy or surgery with use of prosthetic graft material for bypass or patch angioplasty. We report our early experience with a novel approach using a tissue expander (TE) to lengthen the normal native arteries in children with MAS, allowing primary aortic repair without the need for prosthetic graft material. We conducted a retrospective review of patients with MAS undergoing the TE-stimulated lengthening of arteries (TESLA) procedure at our institution from 2010 to 2014. Data are presented as mean (range). Five patients aged 4.8 years (3-8 years) underwent the TESLA procedure. Stages of this procedure include the following: stage I, insertion of retroaortic TE; stage II, serial TE injections; and stage III, final repair with excision of aortic stenosis and primary end-to-end aortic anastomosis. Stage II was completed in 4 months (1-9 months) with 12 (7-20) TE injections. Goal lengthening was achieved in all patients. Stage III could not be completed in one patient because of extreme aortic inflammation, which precluded safe excision of the aortic stenosis and required use of a prosthetic bypass graft. The other four patients completed stage III with two (one to three) additional vessels also requiring reconstruction (renal or mesenteric arteries). At 3.2 years (1-6 years) of follow-up, all patients are doing well. The TESLA procedure allows surgical correction of MAS without the need for prosthetic grafts in young children who are still growing. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  18. In vitro three-dimensional coculturing poly3-hydroxybutyrate-co-3-hydroxyhexanoate with mouse-induced pluripotent stem cells for myocardial patch application.

    PubMed

    Shijun, Xu; Junsheng, Mu; Jianqun, Zhang; Ping, Bo

    2016-03-01

    Identifying a suitable polymeric biomaterial for myocardial patch repair following myocardial infarction, cerebral infarction, and cartilage injury is essential. This study aimed to investigate the effect of the novel polymer material, poly3-hydroxybutyrate-co-3-hydroxyhexanoate, on the adhesion, proliferation, and differentiation of mouse-induced pluripotent stem cells in vitro. Mouse-induced pluripotent stem cells were isolated, expanded, and cultured on either two-dimensional or three-dimensional poly3-hydroxybutyrate-co-3-hydroxyhexanoate films (membranes were perforated to imitate three-dimensional space). Following attachment onto the films, mouse-induced pluripotent stem cell morphology was visualized using scanning electron microscopy. Cell vitality was detected using the Cell Counting Kit-8 assay and cell proliferation was observed using fluorescent 4',6-diamidino-2-phenylindole (DAPI) staining. Mouse-induced pluripotent stem cells were induced into cardiomyocytes by differentiation medium containing vitamin C. A control group in the absence of an inducer was included. Mouse-induced pluripotent stem cell survival and differentiation were observed using immunofluorescence and flow cytometry, respectively. Mouse-induced pluripotent stem cells growth, proliferation, and differentiation were observed on both two-dimensional and three-dimensional poly3-hydroxybutyrate-co-3-hydroxyhexanoate films. Vitamin C markedly improved the efficiency of mouse-induced pluripotent stem cells differentiation into cardiomyocytes on poly3-hydroxybutyrate-co-3-hydroxyhexanoate films. Three-dimensional culture was better at promoting mouse-induced pluripotent stem cell proliferation and differentiation compared with two-dimensional culture. © The Author(s) 2016.

  19. New Surface-Treatment Technique of Concrete Structures Using Crack Repair Stick with Healing Ingredients

    PubMed Central

    Ahn, Tae-Ho; Kim, Hong-gi; Ryou, Jae-Suk

    2016-01-01

    This study focused on the development of a crack repair stick as a new repair method along with self-healing materials that can be used to easily repair the cracks in a concrete structure at the construction site. In developing this new repair technique, the self-healing efficiency of various cementitious materials was considered. Likewise, a crack repair stick was developed to apply to concrete structures with 0.3 mm or lower crack widths. The crack repair stick was made with different materials, such as cement, an expansive material (C12A7), a swelling material, and calcium carbonate, to endow it with a self-healing property. To verify the performance of the crack repair stick for concrete structures, two types of procedures (field experiment and field absorption test) were carried out. As a result of such procedures, it was concluded that the developed crack repair stick could be used on concrete structures to reduce repair expenses and for the improved workability, usability, and serviceability of such structures. On the other hand, to evaluate the self-healing performance of the crack repair stick, various tests were conducted, such as the relative dynamic modulus of elasticity test, the water tightness test, the water permeability test, observation via a microscope, and scanning electron microscope (SEM) analysis. From the results, it is found that water leakage can be prevented and that the durability of a concrete structure can be improved through self-healing. Also, it was verified that the cracks were perfectly closed after 28 days due to application of the crack repair stick. These results indicate the usability of the crack repair stick for concrete structures, and its self-healing efficiency. PMID:28773776

  20. Two intelligent materials, both of which are self-forming and self-repairing; one also self-senses and recycles

    NASA Astrophysics Data System (ADS)

    Dry, Carolyn M.

    1996-04-01

    Two self-forming and repair polymer cementitious composites were developed over a decade apart by the author. Both relied on a nature based paradigm as a model for building, in particular bone formation, repair, and degradation. For the first composite, the proposed material accreted from the ocean, made from a fluids based chemistry, that of seawater. The land based system was not built in-situ but relied on a man made supply of materials which were self-forming, self-repairing and dissolving. But in both cases a fluid based chemistry was necessary for self-building, repair and recycling of a bone-like composite material.

  1. Safety and Efficacy of Single Incision Laparoscopic Surgery for Total Extraperitoneal Inguinal Hernia Repair

    PubMed Central

    2011-01-01

    Almost 20 years after the first laparoscopic inguinal hernia repair was performed, single incision laparoscopic surgery (SILS™) is set to revolutionize minimally invasive surgery. However, the loss of triangulation must be overcome before the technique can be popularized. This study reports the first 100 laparoscopic total extraperitoneal hernia repairs using a single incision. The study cohort comprised 68 patients with a mean age of 44 (range, 18 to 83): 36 unilateral and 32 bilateral hernias. Twelve patients also underwent umbilical hernia repair with the Ventralex patch requiring no additional incisions. A 2.5-cm to 3-cm crescentic incision within the confines of the umbilicus was performed. Standard dissecting instruments and 52-cm/5.5-mm/300 laparoscope were used. Operation times were 50 minutes for unilateral and 80 minutes for bilateral. There was one conversion to conventional 3-port laparoscopic repair and none to open surgery. Outpatient surgery was achieved in all (except one). Analgesic requirements were minimal: 8 Dextropropoxyphene tablets (range, 0 to 20). There were no intraoperative or postoperative complications with a high patient satisfaction score. Single-incision laparoscopic hernia repair is safe and efficient simply by modifying dissection techniques (so-called “inline” and “vertical”). Comparable success can be obtained while negating the risks of bowel and vascular injuries from sharp trocars and achieving improved cosmetic results. PMID:21902942

  2. A PC-PU nanoparticle/PU/decellularized scaffold composite vascular patch: Synergistically optimized overall performance promotes endothelialization.

    PubMed

    Zhang, Jun; Liu, Cheng; Feng, Fuling; Wang, Dawei; Lu, Shuaishuai; Wei, Guo; Mo, Hong; Qiao, Tong

    2017-12-01

    Composite vascular patches have gained increasingly attention due to the limited availability of autologous patches (vascular graft materials made from the blood vessels of the same recipient), the lack of growth capability of nonautologous patches (vascular graft materials made from the blood vessels of a different donor) and the disadvantages of synthetic patches. In this study, we report a highly biocompatible phosphatidylcholine-polyurethane nanoparticle/polyurethane/decellularized scaffold composite vascular patch (PCVP). It was fabricated by a facile method - cosedimentation. Its in vitro blood and cell compatibility including hemolysis, plasma recalcification time, coagulation time, platelet adhesion and cytotoxicity was evaluated. The surface modified with phosphatidylcholine-polyurethane (PC-PU) nanoparticles exhibited the improved anticoagulation activity. The in vivo performance of the PCVP was investigated in a mouse model. The nanopatterned surface that resembled the concave-convex structure of the luminal surface of native blood vessels enhanced cell attachment, proliferation, migration and differentiation. The decellularized scaffold had the mechanical property similar to that of the targeted blood vessels, which could withstand in vivo dynamic blood pressure. The overall performance of the PCVP was synergistically optimized by each layer of the multilayer design. The patched artery remained patent and the formation of endothelial tissue - endothelialization was achieved 30days after the in vivo implantation in a mouse model. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Miniaturized Dual Band Multislotted Patch Antenna on Polytetrafluoroethylene Glass Microfiber Reinforced for C/X Band Applications

    PubMed Central

    Islam, M. T.; Samsuzzaman, M.

    2014-01-01

    This paper introduces a new configuration of compact, triangular- and diamond-slotted, microstrip-fed, low-profile antenna for C/X band applications on polytetrafluoroethylene glass microfiber reinforced material substrate. The antenna is composed of a rectangular-shaped patch containing eight triangles and two diamond-shaped slots and an elliptical-slotted ground plane. The rectangular-shaped patch is obtained by cutting two diamond slots in the middle of the rectangular patch, six triangular slots on the left and right side of the patch, and two triangular slots on the up and down side of the patch. The slotted radiating patch, the elliptical-slotted ground plane, and the microstrip feed enable the matching bandwidth to be widened. A prototype of the optimized antenna was fabricated on polytetrafluoroethylene glass microfiber reinforced material substrate using LPKF prototyping machine and investigated to validate the proposed design. The simulated results are compared with the measured data, and good agreement is achieved. The proposed antenna offers fractional bandwidths of 13.69% (7.78–8.91 GHz) and 10.35% (9.16–10.19 GHz) where S11 < −10 dB at center frequencies of 8.25 GHz and 9.95 GHz, respectively, and relatively stable gain, good radiation efficiency, and omnidirectional radiation patterns in the matching band. PMID:24987742

  4. High-Performance Wireless Ammonia Gas Sensors Based on Reduced Graphene Oxide and Nano-Silver Ink Hybrid Material Loaded on a Patch Antenna.

    PubMed

    Wu, Bian; Zhang, Xingfei; Huang, Beiju; Zhao, Yutong; Cheng, Chuantong; Chen, Hongda

    2017-09-09

    Reduced graphene oxide (rGO) has been studied as a resistive ammonia gas sensor at room temperature. The sensitive hybrid material composed of rGO and nano-silver ink (Ag-ink) was loaded on a microstrip patch antenna to realize high-performance wireless ammonia sensors. The material was investigated using scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS). Firstly, interdigital electrodes (IDEs) printed on the polyethylene terephthalate (PET) by direct printing were employed to measure the variation of resistance of the sensitive material with the ammonia concentration. The results indicated the response of sensor varied from 4.25% to 14.7% under 15-200 ppm ammonia concentrations. Furthermore, the hybrid material was loaded on a microstrip patch antenna fabricated by a conventional printed circuit board (PCB) process, and a 10 MHz frequency shift of the sensor antenna could be observed for 200 ppm ammonia gas. Finally, the wireless sensing property of the sensor antenna was successfully tested using the same emitted antenna outside the gas chamber with a high gain of 5.48 dBi, and an increased reflection magnitude of the emitted antenna due to the frequency mismatch of the sensor antenna was observed. Therefore, wireless ammonia gas sensors loaded on a patch antenna have significant application prospects in the field of Internet of Things (IoTs).

  5. High-Performance Wireless Ammonia Gas Sensors Based on Reduced Graphene Oxide and Nano-Silver Ink Hybrid Material Loaded on a Patch Antenna

    PubMed Central

    Zhang, Xingfei; Huang, Beiju; Zhao, Yutong; Cheng, Chuantong; Chen, Hongda

    2017-01-01

    Reduced graphene oxide (rGO) has been studied as a resistive ammonia gas sensor at room temperature. The sensitive hybrid material composed of rGO and nano-silver ink (Ag-ink) was loaded on a microstrip patch antenna to realize high-performance wireless ammonia sensors. The material was investigated using scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS). Firstly, interdigital electrodes (IDEs) printed on the polyethylene terephthalate (PET) by direct printing were employed to measure the variation of resistance of the sensitive material with the ammonia concentration. The results indicated the response of sensor varied from 4.25% to 14.7% under 15–200 ppm ammonia concentrations. Furthermore, the hybrid material was loaded on a microstrip patch antenna fabricated by a conventional printed circuit board (PCB) process, and a 10 MHz frequency shift of the sensor antenna could be observed for 200 ppm ammonia gas. Finally, the wireless sensing property of the sensor antenna was successfully tested using the same emitted antenna outside the gas chamber with a high gain of 5.48 dBi, and an increased reflection magnitude of the emitted antenna due to the frequency mismatch of the sensor antenna was observed. Therefore, wireless ammonia gas sensors loaded on a patch antenna have significant application prospects in the field of Internet of Things (IoTs). PMID:28891928

  6. Surgical Management of Aortic Coarctation from Infant to Adult

    PubMed Central

    Kaya, Ugur; Colak, Abdurrahim; Becit, Necip; Ceviz, Munacettin; Kocak, Hikmet

    2018-01-01

    Objective: In the present study, we aimed to retrospectively investigate the early and late results of different surgical treatment techniques applied in different age groups with coarctation of the aorta (CoA). Materials and Methods: Between January 2007 and February 2017, 26 patients (12 males, 14 females; mean age: 12.2±12.4 years; range: 29 days–34 years) who underwent surgery with the diagnosis of CoA were evaluated. Overall, 11 of these patients (42.3%) were in the infantile period, whereas 15 patients (57.7%) aged between 6 and 34 years. Resection and end-to-end anastomosis were performed in 13 patients (50%). Bypass grafting was performed in six patients (23.1%), and patch plasty was performed in seven patients (26.9%). Results: A patient (3.8%) who was operated on during the infantile period died early, whereas another patient (3.8%) died 2 years after the surgery. Recoarctation was detected in two patients. A patient underwent balloon dilatation, whereas another patient underwent balloon dilatation and stenting. In patients who underwent re-section and end-to-end anastomosis based on postoperative echocardiography results during follow-up, a lower statistically significant gradient was observed compared with the preoperative period. Despite the decrease in the left ventricular systolic diameter (LVSD) and the increase in the ejection fraction (EF) the decrease in LVSD and increase in EF were not statistically significant. In patients who underwent patch plasty or graft interposition, the low values of the gradient and left ventricular diastolic diameter in the postoperative follow-up were statistically significant. However, the decrease in LVSD and increase in EF were not statistically significant. Conclusions: Our clinical experience suggests that repairing with resection and end-to-end anastomosis is a more appropriate treatment option during the infancy, whereas patch plasty or bypass grafting may be preferred in advanced ages. PMID:29531485

  7. Performance analysis of smart laminated composite plate integrated with distributed AFC material undergoing geometrically nonlinear transient vibrations

    NASA Astrophysics Data System (ADS)

    Shivakumar, J.; Ashok, M. H.; Khadakbhavi, Vishwanath; Pujari, Sanjay; Nandurkar, Santosh

    2018-02-01

    The present work focuses on geometrically nonlinear transient analysis of laminated smart composite plates integrated with the patches of Active fiber composites (AFC) using Active constrained layer damping (ACLD) as the distributed actuators. The analysis has been carried out using generalised energy based finite element model. The coupled electromechanical finite element model is derived using Von Karman type nonlinear strain displacement relations and a first-order shear deformation theory (FSDT). Eight-node iso-parametric serendipity elements are used for discretization of the overall plate integrated with AFC patch material. The viscoelastic constrained layer is modelled using GHM method. The numerical results shows the improvement in the active damping characteristics of the laminated composite plates over the passive damping for suppressing the geometrically nonlinear transient vibrations of laminated composite plates with AFC as patch material.

  8. Applying a biodeposition layer to increase the bond of a repair mortar on a mortar substrate.

    PubMed

    Snoeck, D; Wang, J; Bentz, D P; De Belie, N

    2018-02-01

    One of the major concerns in infrastructure repair is a sufficient bond between the substrate and the repair material, especially for the long-term performance and durability of the repaired structure. In this study, the bond of the repair material on the mortar substrate is promoted via the biodeposition of a calcium carbonate layer by a ureolytic bacterium. X-ray diffraction and scanning electron microscopy were used to examine the interfaces between the repair material and the substrate, as well as the polymorph of the deposited calcium carbonate. The approximately 50 μm thick biodeposition film on the mortar surface mostly consisted of calcite and vaterite. Both the repair material and the substrate tended to show a good adherence to that layer. The bond, as assessed by slant shear specimen testing, was improved by the presence of the biodeposition layer. A further increase was found when engineering the substrate surface using a structured pattern layer of biodeposition.

  9. Point-of-care instrument for monitoring tissue health during skin graft repair

    NASA Astrophysics Data System (ADS)

    Gurjar, R. S.; Seetamraju, M.; Zhang, J.; Feinberg, S. E.; Wolf, D. E.

    2011-06-01

    We have developed the necessary theoretical framework and the basic instrumental design parameters to enable mapping of subsurface blood dynamics and tissue oxygenation for patients undergoing skin graft procedures. This analysis forms the basis for developing a simple patch geometry, which can be used to map by diffuse optical techniques blood flow velocity and tissue oxygenation as a function of depth in subsurface tissue.skin graft, diffuse correlation analysis, oxygen saturation.

  10. Corrosion Potential Monitoring for Polymer Composite Wrapping and Galvanic CP System for Reinforced Concrete Marine Piles

    DTIC Science & Technology

    2010-02-01

    deteriorated – Rebar corrosion – Spalling concrete Repair Options • Patching • Polymeric composite wraps • Pre-fabricated composite shell with CP Objective... Corrosion Potential Monitoring for Polymer Composite Wrapping and Galvanic CP System for Reinforced Concrete Marine Piles David Bailey, Richard...Command DoD Corrosion Problem • Piers and wharves – Critical facilities – $14.5M maintenance costs – Reinforced concrete piles • Aged and

  11. A Feasibility Study into the Active Smart Patch Concept for Composite Bonded Repairs

    DTIC Science & Technology

    2008-08-01

    electrical resistance foil gauges and PVDF (polyvinylidene) piezoelectric film to sense the local strain relaxation that occurs in re- sponse to failure of...structural components, like a wing skin, that are ‘thin’ in comparison to the wavelengths of low frequency ultrasound , and therefore act as efficient...region for the respective excitation frequency. The processed experimental data is compared to theoretical dispersion curves for both Lamb waves and

  12. Pediatric ocular injury secondary to a Burmese python bite.

    PubMed

    Behrens, Alice W; Jones, Maria H; Lowery, R Scott

    2018-03-22

    We report the case of a 6-year-old girl with a penetrating ocular injury caused by a Burmese python. She received intravenous cefazolin before presenting and was treated thereafter with daily topical antibiotics and atropine. Six weeks after injury, she underwent cataract extraction and sulcus implantation of an intraocular lens and iris synechiolysis, with postoperative patching. Final visual outcome was excellent despite no globe repair was performed. Published by Elsevier Inc.

  13. Aeronautical Research Laboratories Structures Division Annual Report 1979-80

    DTIC Science & Technology

    1981-04-01

    8217 :- LLWL 0 > D z cw iLU U Cn C 0 Jojoe ; ou!,sos SSJI 20 12.1.5 Fibre composite patch repair A report has been completea on the design of boron fibre...bl.R.Ae.S., M.I.L.Aust. S.R. Sarrailhe, C.Eng., M.I.Hech.E., M.I.h.Aust. Experimental Officer Class 2 R.P. Carey , B.Hech.E., M.I.E.Aust. R.G. Parker

  14. In utero repair of myelomeningocele: experimental pathophysiology, initial clinical experience, and outcomes.

    PubMed

    Farmer, Diana L; von Koch, Cornelia S; Peacock, Warwick J; Danielpour, Moise; Gupta, Nalin; Lee, Hanmin; Harrison, Michael R

    2003-08-01

    Experimental work raises the possibility that in utero repair of myelomeningocele (MMC) may improve lower extremity, bladder, and bowel function, ameliorate the Arnold-Chiari malformation, and decrease the need for postnatal shunting. We previously developed fetal lamb models to create and reverse lower extremity damage and the Arnold-Chiari malformation in utero. We then applied our extensive experience with fetal surgery, including fetal endoscopic (fetoscopic) surgical manipulation, to develop techniques for MMC repair. A tertiary referral center. All patients treated between 1998 and 2002 for a prenatally diagnosed MMC. Either fetoscopic MMC repair, fetoscopic patch repair, or limited maternal hysterotomy and microsurgical 3-layered fetal MMC repair was performed. Gestational age at delivery, survival, neurologic outcome, and need for ventricular shunting at 1 year. Complete fetoscopic repair was accomplished in 1 fetus. Two other fetuses underwent partial fetoscopic procedures. The remaining 10 patients underwent limited maternal hysterotomy and microsurgical 3-layered fetal MMC repair. Four of 13 patients died, and the mean gestational age at delivery of 11 fetuses born alive was 31 weeks. Five of 9 required ventricular shunting by age 1 year. In 2 patients, lower extremity function improved by more than 2 vertebral levels compared with prenatal ultrasonography. Five of 10 patients who lived longer than 3 weeks required postnatal wound revision within 7 days after birth. Fetoscopic repair, although feasible, does not yet yield optimal surgical results. Open surgical repair before 22 weeks' gestation is physiologically sound and technically feasible. One third of patients appear to be spared the need for a shunt at age 1 year, but improvement in distal neurologic function is less clear. Additionally, fetal mortality is associated with this procedure. Our results complement the data published by groups at Children's Hospital of Philadelphia, in Pennsylvania, and Vanderbilt University, Nashville, Tenn. A National Institutes of Health-sponsored prospective randomized trial is now underway at these 3 centers to compare fetal repair with postnatal repair.

  15. Vacuum/Zero Net-Gravity Application for On-Orbit TPS Tile Repair

    NASA Technical Reports Server (NTRS)

    Harvey, Gale A.; Humes, Donald H.; Siochi, Emilie J.

    2004-01-01

    The Orbiter Columbia catastrophically failed during reentry February 1, 2003. All Space Shuttle flights were suspended, including logistics support for the International Space Station. NASA Langley Research Center s (LaRC) Structures and Materials Competency is performing characterizations of candidate materials for on-orbit repair of orbiter Thermal Protection System (TPS) tiles to support Return-to-Flight activities led by Johnson Space Center (JSC). At least ten materials properties or attributes (adhesion to damage site, thermal protection, char/ash strength, thermal expansion, blistering, flaming, mixing ease, application in vacuum and zero gravity, cure time, shelf or storage life, and short-term outgassing and foaming) of candidate materials are of interest for on-orbit repair. This paper reports application in vacuum and zero net-gravity (for viscous flow repair materials). A description of the test apparatus and preliminary results of several candidate materials are presented. The filling of damage cavities is different for some candidate repair materials in combined vacuum and zero net-gravity than in either vacuum or zero net-gravity alone.

  16. Vacuum/Zero Net-Gravity Application for On-Orbit TPS Tile Repair

    NASA Technical Reports Server (NTRS)

    Harvey, Gale A.; Humes, Donald H.; Siochi, Emilie J.

    2004-01-01

    The Orbiter Columbia catastrophically failed during reentry February 1, 2003. All space Shuttle flights were suspended, including logistics support for the International Space Station. NASA LaRC s Structures and Materials Competency is performing characterizations of candidate materials for on-orbit repair of orbiter Thermal Protection System (TPS) tiles to support Return-to-Flight activities led by JSC. At least ten materials properties or attributes (adhesion to damage site, thermal protection, char/ash strength, thermal expansion, blistering, flaming, mixing ease, application in vacuum and zero gravity, cure time, shelf or storage life, and short-term outgassing and foaming) of candidate materials are of interest for on-orbit repair. This paper reports application in vacuum and zero net-gravity (for viscous flow repair materials). A description of the test apparatus and preliminary results of several candidate materials are presented. The filling of damage cavities is different for some candidate repair materials in combined vacuum and zero net-gravity than in either vacuum or zero net- gravity alone.

  17. New Materials for the Repair of Polyimide Electrical Wire Insulation

    NASA Technical Reports Server (NTRS)

    2008-01-01

    Two viable polyimide backbone materials have been identified that will allow the repair of polyimide electrical wire insulation found on the Space Shuttle and other aging aircraft. This identification is the outcome of ongoing efforts to assess the viability of using such polyimides and polyimide precursors (polyamic acids [PAAs]) as repair materials for aging polyimide electrical wire insulation. These repair materials were selected because they match the chemical makeup of the underlying wire insulation as closely as possible. This similarity allows for maximum compatibility, coupled with the outstanding physical properties of polyimides. The two polyimide backbone materials allow the polymer to be extremely flexible and to melt at low temperatures. A polymer chain end capping group that allows the polymer to crosslink into a nonflowable repair upon curing at around 200 C was also identified.

  18. Effect of repair resin type and surface treatment on the repair strength of polyamide denture base resin.

    PubMed

    Gundogdu, Mustafa; Yanikoglu, Nuran; Bayindir, Funda; Ciftci, Hilal

    2015-01-01

    The purpose of the present study was to evaluate the effects of different repair resins and surface treatments on the repair strength of a polyamide denture base material. Polyamide resin specimens were prepared and divided into nine groups according to the surface treatments and repair materials. The flexural strengths were measured with a 3-point bending test. Data were analyzed with a 2-way analysis of variance, and the post-hoc Tukey test (α=0.05). The effects of the surface treatments on the surface of the polyamide resin were examined using scanning electron microscopy. The repair resins and surface treatments significantly affected the repair strength of the polyamide denture base material (p<0.05); however, no significant differences were observed interaction between the factors (p>0.05). The flexural strength of the specimens repaired with the polyamide resin was significantly higher than that of those repaired with the heat-polymerized and autopolymerizing acrylic resins.

  19. Applications of Piezoelectric Materials in Structural Health Monitoring and Repair: Selected Research Examples

    PubMed Central

    Duan, Wen Hui; Wang, Quan; Quek, Ser Tong

    2010-01-01

    The paper reviews the recent applications of piezoelectric materials in structural health monitoring and repair conducted by the authors. First, commonly used piezoelectric materials in structural health monitoring and structure repair are introduced. The analysis of plain piezoelectric sensors and actuators and interdigital transducer and their applications in beam, plate and pipe structures for damage detection are reviewed in detail. Second, an overview is presented on the recent advances in the applications of piezoelectric materials in structural repair. In addition, the basic principle and the current development of the technique are examined. PMID:28883375

  20. Microstructure formation and fracturing characteristics of grey cast iron repaired using laser.

    PubMed

    Yi, Peng; Xu, Pengyun; Fan, Changfeng; Yang, Guanghui; Liu, Dan; Shi, Yongjun

    2014-01-01

    The repairing technology based on laser rapid fusion is becoming an important tool for fixing grey cast iron equipment efficiently. A laser repairing protocol was developed using Fe-based alloy powders as material. The microstructure and fracturing feature of the repaired zone (RZ) were analyzed. The results showed that regionally organized RZ with good density and reliable metallurgical bond can be achieved by laser repairing. At the bottom of RZ, dendrites existed in similar direction and extended to the secondary RZ, making the grains grow extensively with inheritance with isometric grains closer to the surface substrate. The strength of the grey cast iron base material was maintained by laser repairing. The base material and RZ were combined with robust strength and fracture resistance. The prevention and deflection of cracking process were analyzed using a cracking process model and showed that the overall crack toughness of the materials increased.

  1. Microstructure Formation and Fracturing Characteristics of Grey Cast Iron Repaired Using Laser

    PubMed Central

    Liu, Dan; Shi, Yongjun

    2014-01-01

    The repairing technology based on laser rapid fusion is becoming an important tool for fixing grey cast iron equipment efficiently. A laser repairing protocol was developed using Fe-based alloy powders as material. The microstructure and fracturing feature of the repaired zone (RZ) were analyzed. The results showed that regionally organized RZ with good density and reliable metallurgical bond can be achieved by laser repairing. At the bottom of RZ, dendrites existed in similar direction and extended to the secondary RZ, making the grains grow extensively with inheritance with isometric grains closer to the surface substrate. The strength of the grey cast iron base material was maintained by laser repairing. The base material and RZ were combined with robust strength and fracture resistance. The prevention and deflection of cracking process were analyzed using a cracking process model and showed that the overall crack toughness of the materials increased. PMID:25032230

  2. Wellbore Seal Repair Using Nanocomposite Materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stormont, John

    2016-08-31

    Nanocomposite wellbore repair materials have been developed, tested, and modeled through an integrated program of laboratory testing and numerical modeling. Numerous polymer-cement nanocomposites were synthesized as candidate wellbore repair materials using various combinations of base polymers and nanoparticles. Based on tests of bond strength to steel and cement, ductility, stability, flowability, and penetrability in opening of 50 microns and less, we identified Novolac epoxy reinforced with multi-walled carbon nanotubes and/or alumina nanoparticles to be a superior wellbore seal material compared to conventional microfine cements. A system was developed for testing damaged and repaired wellbore specimens comprised of a cement sheathmore » cast on a steel casing. The system allows independent application of confining pressures and casing pressures while gas flow is measured through the specimens along the wellbore axis. Repair with the nanocomposite epoxy base material was successful in dramatically reducing the flow through flaws of various sizes and types, and restoring the specimen comparable to an intact condition. In contrast, repair of damaged specimens with microfine cement was less effective, and the repair degraded with application of stress. Post-test observations confirm the complete penetration and sealing of flaws using the nanocomposite epoxy base material. A number of modeling efforts have supported the material development and testing efforts. We have modeled the steel-repair material interface behavior in detail during slant shear tests, which we used to characterize bond strength of candidate repair materials. A numerical model of the laboratory testing of damaged wellbore specimens was developed. This investigation found that microannulus permeability can satisfactorily be described by a joint model. Finally, a wellbore model has been developed that can be used to evaluate the response of the wellbore system (casing, cement, and microannulus), including the use of either cement or a nanocomposite in the microannulus to represent a repaired system. This wellbore model was successfully coupled with a field-scale model of CO 2 injection, to enable predictions of stress and strains in the wellbore subjected to subsurface changes (i.e. domal uplift) associated with fluid injection.« less

  3. Design of an innovative magnetostrictive patch actuator

    NASA Astrophysics Data System (ADS)

    Cinquemani, S.; Giberti, H.

    2015-04-01

    Magnetostrictive actuators can be profitably used to reduce vibration in structures. However, this technology has been exploited only to develop inertial actuators, while patches actuators have not been ever used in practice. Patches actuators consist on a layer of magnetostrictive material, which has to be stuck to the surface of the vibrating structure, and on a coil surrounding the layer itself. However, the presence of the winding severely limits the use of such devices. As a matter of fact, the scientific literature reports only theoretical uses of such actuators, but, in practice it does not seem they were ever used. This paper presents an innovative solution to improve the structure of the actuator patches, allowing their use in several practical applications. The principle of operation of these devices is rather simple. The actuator patch is able to generate a local deformation of the surface of the vibrating structure so as to introduce an equivalent damping that dissipates the kinetic energy associated to the vibration. This deformation is related to the behavior of the magnetostrictive material immersed in a variable magnetic field generated by the a variable current flowing in the winding. Contrary to what suggested in the theoretical literature, the designed device has the advantage of generating the variable magnetic field no longer in close proximity of the material, but in a different area, thus allowing a better coupling. The magnetic field is then conveyed through a suitable ferromagnetic structure to the magnetostrictive material. The device has been designed and simulated through FEA. Results confirm that the new configuration can easily overcome all the limits of traditional devices.

  4. Manufacturing and testing of active composite panels with embedded piezoelectric sensors and actuators: wires out by molded-in holes

    NASA Astrophysics Data System (ADS)

    Ghasemi-Nejhad, Mehrdad N.; Pourjalali, Saeid

    2003-08-01

    This work presents manufacturing and testing of active composite panels (ACPs) with embedded piezoelectric sensors and actuators. The composite material employed here is a plain weave carbon epoxy prepreg fabric with about 0.33 mm ply thickness. The piezoelectric patches employed here are Continuum Control Corporation, CCC, (recently Continuum Photonics, Inc) active fiber composite patches with 0.33 mm thickness, i.e. close to the composite ply thickness. Composite cut-out layers are used to fill the space around the embedded piezoelectric patches to minimize the problems associated with ply drops in composites. The piezoelectric patches were embedded inside the composite laminate. High-temperature wires were soldered to the piezoelectric leads, insulated from the carbon substructure by high-temperature materials, and were taken out of the composite laminates employing a molded-in hole technique that reduces the stress concentration as opposed to a drilled hole, and thereby enhancing the performance of the composite structure. The laminated ACP"s were co-cured inside an autoclave employing the cure cycle recommended by the composite material supplier. The curie temperature of the embedded piezoelectric patches should be well above the curing temperature of the composite materials as was the case here. The manufactured ACP beams and plates were trimmed and then tested for their functionality. Vibration suppression as well as simultaneous vibration suppression and precision positioning tests, using PID control as well as Hybrid Adaptive Control techniques were successfully conducted on the manufactured ACP beams and their functionality were demonstrated. Recommendations on the use of this embedding technique for ACPs are provided.

  5. In vivo laser assisted end-to-end anastomosis with ICG-infused chitosan patches

    NASA Astrophysics Data System (ADS)

    Rossi, Francesca; Matteini, Paolo; Esposito, Giuseppe; Scerrati, Alba; Albanese, Alessio; Puca, Alfredo; Maira, Giulio; Rossi, Giacomo; Pini, Roberto

    2011-07-01

    Laser assisted vascular repair is a new optimized technique based on the use of ICG-infused chitosan patch to close a vessel wound, with or even without few supporting single stitches. We present an in vivo experimental study on an innovative end-to-end laser assisted vascular anastomotic (LAVA) technique, performed with the application of ICGinfused chitosan patches. The photostability and the mechanical properties of ICG-infused chitosan films were preliminary measured. The in vivo study was performed in 10 New Zealand rabbits. After anesthesia, a 3-cm segment of the right common carotid artery was exposed, thus clamped proximally and distally. The artery was then interrupted by means of a full thickness cut. Three single microsutures were used to approximate the two vessel edges. The ICG-infused chitosan patch was rolled all over the anastomotic site and welded by the use of a diode laser emitting at 810 nm and equipped with a 300 μm diameter optical fiber. Welding was obtained by delivering single laser spots to induce local patch/tissue adhesion. The result was an immediate closure of the anastomosis, with no bleeding at clamps release. Thus animals underwent different follow-up periods, in order to evaluate the welded vessels over time. At follow-up examinations, all the anastomoses were patent and no bleeding signs were documented. Samples of welded vessels underwent histological examinations. Results showed that this technique offer several advantages over conventional suturing methods: simplification of the surgical procedure, shortening of the operative time, better re-endothelization and optimal vascular healing process.

  6. Proof of concept : biocement for road repair.

    DOT National Transportation Integrated Search

    2015-03-01

    Road repair is an expensive operation every year. This cost can be greatly reduced if waste materials from the mining and biofuel : industries can be used to substitute conventional materials for road repair or construction. The objective of this pro...

  7. Damage tolerance of bonded composite aircraft repairs for metallic structures

    NASA Astrophysics Data System (ADS)

    Clark, Randal John

    This thesis describes the development and validation of methods for damage tolerance substantiation of bonded composite repairs applied to cracked plates. This technology is used to repair metal aircraft structures, offering improvements in fatigue life, cost, manufacturability, and inspectability when compared to riveted repairs. The work focuses on the effects of plate thickness and bending on repair life, and covers fundamental aspects of fracture and fatigue of cracked plates and bonded joints. This project falls under the UBC Bonded Composite Repair Program, which has the goal of certification and widespread use of bonded repairs in civilian air transportation. This thesis analyses the plate thickness and transverse stress effects on fracture of repaired plates and the related problem of induced geometrically nonlinear bending in unbalanced (single-sided) repairs. The author begins by developing a classification scheme for assigning repair damage tolerance substantiation requirements based upon stress-based adhesive fracture/fatigue criteria and the residual strength of the original structure. The governing equations for bending of cracked plates are then reformulated and line-spring models are developed for linear and nonlinear coupled bending and extension of reinforced cracks. The line-spring models were used to correct the Wang and Rose energy method for the determination of the long-crack limit stress intensity, and to develop a new interpolation model for repaired cracks of arbitrary length. The analysis was validated using finite element models and data from mechanical tests performed on hybrid bonded joints and repair specimens that are representative of an in-service repair. This work will allow designers to evaluate the damage tolerance of the repaired plate, the adhesive, and the composite patch, which is an airworthiness requirement under FAR (Federal Aviation Regulations) 25.571. The thesis concludes by assessing the remaining barriers to certification of bonded repairs, discussing the results of the analysis, and making suggestions for future work. The developed techniques should also prove to be useful for the analysis of fibre-reinforced metal laminates and other layered structures. Some concepts are general and should be useful in the analysis of any plate with large in-plane stress gradients that lead to significant transverse stresses.

  8. NEIL3 Repairs Telomere Damage during S Phase to Secure Chromosome Segregation at Mitosis.

    PubMed

    Zhou, Jia; Chan, Jany; Lambelé, Marie; Yusufzai, Timur; Stumpff, Jason; Opresko, Patricia L; Thali, Markus; Wallace, Susan S

    2017-08-29

    Oxidative damage to telomere DNA compromises telomere integrity. We recently reported that the DNA glycosylase NEIL3 preferentially repairs oxidative lesions in telomere sequences in vitro. Here, we show that loss of NEIL3 causes anaphase DNA bridging because of telomere dysfunction. NEIL3 expression increases during S phase and reaches maximal levels in late S/G2. NEIL3 co-localizes with TRF2 and associates with telomeres during S phase, and this association increases upon oxidative stress. Mechanistic studies reveal that NEIL3 binds to single-stranded DNA via its intrinsically disordered C terminus in a telomere-sequence-independent manner. Moreover, NEIL3 is recruited to telomeres through its interaction with TRF1, and this interaction enhances the enzymatic activity of purified NEIL3. Finally, we show that NEIL3 interacts with AP Endonuclease 1 (APE1) and the long-patch base excision repair proteins PCNA and FEN1. Taken together, we propose that NEIL3 protects genome stability through targeted repair of oxidative damage in telomeres during S/G2 phase. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.

  9. Process Optimization of Bismaleimide (BMI) Resin Infused Carbon Fiber Composite

    NASA Technical Reports Server (NTRS)

    Ehrlich, Joshua W.; Tate, LaNetra C.; Cox, Sarah B.; Taylor, Brian J.; Wright, M. Clara; Faughnan, Patrick D.; Batterson, Lawrence M.; Caraccio, Anne J.; Sampson, Jeffery W.

    2013-01-01

    Engineers today are presented with the opportunity to design and build the next generation of space vehicles out of the lightest, strongest, and most durable materials available. Composites offer excellent structural characteristics and outstanding reliability in many forms that will be utilized in future aerospace applications including the Commercial Crew and Cargo Program and the Orion space capsule. NASA's Composites for Exploration (CoEx) project researches the various methods of manufacturing composite materials of different fiber characteristics while using proven infusion methods of different resin compositions. Development and testing on these different material combinations will provide engineers the opportunity to produce optimal material compounds for multidisciplinary applications. Through the CoEx project, engineers pursue the opportunity to research and develop repair patch procedures for damaged spacecraft. Working in conjunction with Raptor Resins Inc., NASA engineers are utilizing high flow liquid infusion molding practices to manufacture high-temperature composite parts comprised of intermediate modulus 7 (IM7) carbon fiber material. IM7 is a continuous, high-tensile strength composite with outstanding structural qualities such as high shear strength, tensile strength and modulus as well as excellent corrosion, creep, and fatigue resistance. IM7 carbon fiber, combined with existing thermoset and thermoplastic resin systems, can provide improvements in material strength reinforcement and deformation-resistant properties for high-temperature applications. Void analysis of the different layups of the IM7 material discovered the largest total void composition within the [ +45 , 90 , 90 , -45 ] composite panel. Tensile and compressional testing proved the highest mechanical strength was found in the [0 4] layup. This paper further investigates the infusion procedure of a low-cost/high-performance BMI resin into an IM7 carbon fiber material and the optical, chemical, and mechanical analyses performed.

  10. Laboratory and Field Evaluation of Rapid Setting Cementitious Materials for Large Crater Repair

    DTIC Science & Technology

    2010-05-01

    frame used within which to complete the repair was the current NATO standard of 4 hr. A total of 6 simulated craters were prepared, with each repair...Combat Command 129 Andrews Street Langley Air Force Base, VA 23665 ERDC TR-10-4 ii Abstract: Current practice for expedient runway repair...penalty. Numerous commercial products are available. A full-scale field test was conducted using rapid setting materials to repair simulated bomb craters

  11. Active Piezoelectric Vibration Control of Subscale Composite Fan Blades

    NASA Technical Reports Server (NTRS)

    Duffy, Kirsten P.; Choi, Benjamin B.; Provenza, Andrew J.; Min, James B.; Kray, Nicholas

    2012-01-01

    As part of the Fundamental Aeronautics program, researchers at NASA Glenn Research Center (GRC) are investigating new technologies supporting the development of lighter, quieter, and more efficient fans for turbomachinery applications. High performance fan blades designed to achieve such goals will be subjected to higher levels of aerodynamic excitations which could lead to more serious and complex vibration problems. Piezoelectric materials have been proposed as a means of decreasing engine blade vibration either through a passive damping scheme, or as part of an active vibration control system. For polymer matrix fiber composite blades, the piezoelectric elements could be embedded within the blade material, protecting the brittle piezoceramic material from the airflow and from debris. To investigate this idea, spin testing was performed on two General Electric Aviation (GE) subscale composite fan blades in the NASA GRC Dynamic Spin Rig Facility. The first bending mode (1B) was targeted for vibration control. Because these subscale blades are very thin, the piezoelectric material was surface-mounted on the blades. Three thin piezoelectric patches were applied to each blade two actuator patches and one small sensor patch. These flexible macro-fiber-composite patches were placed in a location of high resonant strain for the 1B mode. The blades were tested up to 5000 rpm, with patches used as sensors, as excitation for the blade, and as part of open- and closed-loop vibration control. Results show that with a single actuator patch, active vibration control causes the damping ratio to increase from a baseline of 0.3% critical damping to about 1.0% damping at 0 RPM. As the rotor speed approaches 5000 RPM, the actively controlled blade damping ratio decreases to about 0.5% damping. This occurs primarily because of centrifugal blade stiffening, and can be observed by the decrease in the generalized electromechanical coupling with rotor speed.

  12. Cleaning Aged EPDM Rubber Roofing Membrane Material for Patching: Laboratory Investigations and Recommendations

    DTIC Science & Technology

    1992-08-01

    Cleaning Aged EPDM Rubber Roofing Membrane Material for Patching: Laboratory Investigations and Recommendations Walter J. Rossiter, Jr. T N n-’T ic...condition of the aged EPDM rubber before bonding. This study assessed the effectiveness of different cleaning methods for preparing aged EPDM membranes for...REPORT DATE 3. REPORT TYPE AND DATES COVERED August 1992 Final 4. TITLE AND SUBTITLE 5. FUNDING NUMBERS Cleaning Aged EPDM Rubber Roofing Membrane

  13. An Active Patch Model for Real World Texture and Appearance Classification

    PubMed Central

    Mao, Junhua; Zhu, Jun; Yuille, Alan L.

    2014-01-01

    This paper addresses the task of natural texture and appearance classification. Our goal is to develop a simple and intuitive method that performs at state of the art on datasets ranging from homogeneous texture (e.g., material texture), to less homogeneous texture (e.g., the fur of animals), and to inhomogeneous texture (the appearance patterns of vehicles). Our method uses a bag-of-words model where the features are based on a dictionary of active patches. Active patches are raw intensity patches which can undergo spatial transformations (e.g., rotation and scaling) and adjust themselves to best match the image regions. The dictionary of active patches is required to be compact and representative, in the sense that we can use it to approximately reconstruct the images that we want to classify. We propose a probabilistic model to quantify the quality of image reconstruction and design a greedy learning algorithm to obtain the dictionary. We classify images using the occurrence frequency of the active patches. Feature extraction is fast (about 100 ms per image) using the GPU. The experimental results show that our method improves the state of the art on a challenging material texture benchmark dataset (KTH-TIPS2). To test our method on less homogeneous or inhomogeneous images, we construct two new datasets consisting of appearance image patches of animals and vehicles cropped from the PASCAL VOC dataset. Our method outperforms competing methods on these datasets. PMID:25531013

  14. Orbital implant exposure treatment with porcine dermal collagen patching.

    PubMed

    Alwitry, A; Burns, S J; Abercrombie, L C

    2006-09-01

    To present a small case series of orbital implant exposures treated with porcine dermal collagen (Permacol, Tissue Science Laboratories PLC, Aldershot, Hants, UK) patching. A retrospective chart review of three cases of orbital implant exposure treated with Permacol patching. Three cases were identified. There were 4 operative episodes of Permacol patching (one socket had two attempts at permacol patching). In all 4 cases the patch rapidly failed and melted away leaving behind the orbital implant exposure. All 3 patients required implant removal. Orbital implant exposure remains a major long-term complication of evisceration and enucleation procedures. On the basis of our experience, we would not recommend using Permacol as a non-autologous material for covering exposed Medpor (Medpor, Porex Surgical, Atlanta, Georgia, USA) orbital implants. Further study is required to fully assess the safety and efficacy profile of Permacol in socket surgery.

  15. Nickel-titanium wire as a flexor tendon suture material: an ex vivo study.

    PubMed

    Karjalainen, T; Göransson, H; Viinikainen, A; Jämsä, T; Ryhänen, J

    2010-07-01

    Nickel-titanium shape memory alloy (NiTi) is a new suture material that is easy to handle, is strong, and biocompatible. The purpose of this study was to evaluate the material properties and biomechanical behaviour of 150 microm and 200 microm NiTi wires in flexor tendon repair. Braided polyester (4-0 Ethibond) was used as control. Fifty fresh-frozen porcine flexor tendons were repaired using the Pennington modification of the Kessler repair or a double Kessler technique. NiTi wires were stiffer and reached higher tensile strength compared to braided polyester suture. Repairs with 200 microm NiTi wire had a higher yield force, ultimate force and better resistance to gapping than 4-0 braided polyester repairs. Repairs made with 200 microm NiTi wire achieved higher stiffness and ultimate force than repairs made with 150 microm NiTi wire.

  16. Triton - Detail of Dark and Light Material

    NASA Image and Video Library

    1996-09-26

    NASA's Voyager 2 acquired this black and white image of Triton, Neptune's largest satellite, during the night of Aug. 24-25, 1989. Triton's limb cuts obliquely across the middle of the image. The field of view is about 1,000 km (600 miles) across. Three irregular dark areas, surrounded by brighter material, dominate the image. Low-lying material with intermediate albedo occupies the central area, and fresh craters occur along the right margin. Sub-parallel alignment of linear patches of dark material shown in the lower and left part of the image suggests that the patches are structurally controlled. http://photojournal.jpl.nasa.gov/catalog/PIA00056

  17. Damage Tolerant Repair Techniques for Pressurized Aircraft Fuselages

    DTIC Science & Technology

    1994-06-06

    crack patching effectiveness, long cracks ( Erdogan ) 186 Vii Acknowledgments My three years of Ph.D. work would have been impossible without the...fatigue GST, GLARE 2 " " 20 20 static, no fatigue *Unidirectional SP500 carbon/epoxy tape . *Fatigue load did not initiate a crack. The saw cut was...assurnption It further implies zero crack opening under the pat(:r The Erdogan solutior (51 for two Coiinear Ctacks can be expressed as: %A F -. " (621 F

  18. Peripheral Nerve Repair and Prevention of Neuroma Formation

    DTIC Science & Technology

    2014-09-01

    Magee1), ADRB3, β arrestin, Patched 1 (Ptch1) and 2, desert hedgehog (Dhh), smoothen (Smo), Src kinase, and UCP1. (Months 6-36) c. We will also use the...antibody. Figure 9. Representative photomicrographs of desert hedgehog staining in perineurial fibroblasts. A.) C57/BL6 mouse nerve was isolated 3...days after BMP2 induction stained with desert hedgehog (red) and NF (green). P. perineurium; E. endoneurium. Note that the mouse nerve, unlike the

  19. Surgical management of anomalous pulmonary venous connection to the superior vena cava - early results

    PubMed Central

    Chandra, Dinesh; Gupta, Anubhav; Nath, Ranjit K.; kazmi, Aamir; Grover, Vijay; Gupta, Vijay K.

    2013-01-01

    Background The anatomical variability in patients with anomalous pulmonary venous connection to superior vena cava presents a surgical challenge. The problem is further compounded by the common occurrence of postoperative complications like arrhythmias and obstruction of the superior vena cava or pulmonary veins. We present our experience of managing this subset using the two patch and Warden's techniques. Patients and methods Between June 2011 and September 2012, 7 patients with APVC to the SVC were operated in our institute. After delineating the anatomy, five of them had a two patch repair and two were managed with Warden's technique. Results There was no in-hospital mortality or early mortality over a mean follow-up of 9.66 ± 3.88 months (range 6–15 months). All the patients on follow-up had unobstructed pulmonary venous and SVC drainage on echocardiography and all of them were in normal sinus rhythm. Conclusions Anomalous pulmonary venous connection to superior vena cava is a challenging subset of patients in whom the surgical management needs to be individualized. The detailed anatomy must be delineated using echocardiography with or without CT angiography before deciding the surgical plan. This entity can be repaired with excellent immediate and early results. However, these patients must be closely followed up for complications like systemic and pulmonary venous obstruction and sinus node dysfunction. PMID:24206880

  20. STS-121 Mission Patch

    NASA Image and Video Library

    2005-06-01

    STS121-S-001 (June 2005) --- The STS-121 patch depicts the space shuttle docked with the International Space Station (ISS) in the foreground, overlaying the astronaut symbol with three gold columns and a gold star. The ISS is shown in the configuration that it will be in during the STS-121 mission. The background shows the nighttime Earth with a dawn breaking over the horizon. STS-121, ISS mission ULF1.1, is the final Shuttle Return to Flight test mission. This utilization and logistics flight will bring a multipurpose logistics module (MPLM) to the ISS with several thousand pounds of new supplies and experiments. In addition, some new orbital replacement units (ORUs) will be delivered and stowed externally on ISS on a special pallet. These ORUs are spares for critical machinery located on the outside of the ISS. During this mission the crew will also carry out testing of shuttle inspection and repair hardware, as well as evaluate operational techniques and concepts for conducting on-orbit inspection and repair. The NASA insignia design for space shuttle flights is reserved for use by the astronauts and for other official use as the NASA Administrator may authorize. Public availability has been approved only in the forms of illustrations by the various news media. When and if there is any change in this policy, which is not anticipated, the change will be publicly announced. Photo credit: NASA

  1. Combined open and laparoscopic approach to chronic pain following open inguinal hernia repair.

    PubMed

    Rosen, M J; Novitsky, Y W; Cobb, W S; Kercher, K W; Heniford, B Todd

    2006-03-01

    Chronic groin pain is the most common long-term complication after open inguinal hernia repair. Traditional surgical management of the associated neuralgia consists of injection therapy followed by groin exploration, mesh removal, and nerve transection. The resultant hernia defect may be difficult to repair from an anterior approach. We evaluate the outcomes of a combined laparoscopic and open approach for the treatment of chronic groin pain following open inguinal herniorrhaphy. All patients who underwent groin exploration for chronic neuralgia after a prior open inguinal hernia repair were prospectively analyzed. Patient demographics, type of prior hernia repair, and prior nonoperative therapies were recorded. The operation consisted of a standard three trocar laparoscopic transabdominal preperitoneal hernia repair, followed by groin exploration, mesh removal, and nerve transection. Outcome measures included recurrent groin pain, numbness, hernia recurrence, and complications. Twelve patients (11 male and 1 female) with a mean age of 41 years (range 29-51) underwent combined laparoscopic and open treatment for chronic groin pain. Ten patients complained of unilateral neuralgia, one patient had bilateral complaints, and one patient complained of orchalgia. All patients failed at least two attempted percutaneous nerve blocks. Prior repairs included Lichtenstein (n=9), McVay (n=1), plug and patch (n=1), and Shouldice (n=1). There were no intraoperative complications or wound infections. With a minimum of 6 weeks follow up, all patients were significantly improved. One patient complained of intermittent minor discomfort that required no further therapy. Two patients had persistent numbness in the ilioinguinal nerve distribution but remained satisfied with the procedure. A combined laparoscopic and open approach for postherniorrhaphy groin pain results in good to excellent patient satisfaction with no perioperative morbidity. It may be the preferred technique for the definitive management of chronic neuralgia after prior open hernia repair.

  2. Utility of patch testing for patients with drug eruption.

    PubMed

    Ohtoshi, S; Kitami, Y; Sueki, H; Nakada, T

    2014-04-01

    Patch testing is less dangerous than oral provocation testing for identification of the causative drug for patients with drug eruption; however, its usefulness for such identification is controversial. To clarify the rates of positive patch testing for patients with drug eruption, classified by causative drugs and clinical features. We analysed results during the period 1990-2010 for 444 patients (151 men, 293 women; mean ± SD age 49.9 ± 18.6 years) who were tested for drug eruption. In the patient group, there were 309 people (69.1%) with maculopapular eruption and 31 (6.9%) with severe drug eruption. The test materials were applied to the back and left for 2 days under occlusion, then results were assessed by the International Contact Dermatitis Research Group (ICDRG) scoring system 3 days after application. Reactions of + to +++ were regarded as positive. Of the 444 patients, 100 (22.4%) had a positive patch test result to a suspected drug. Positive rates were 23.6% and 20.0% for maculopapular eruption and fixed drug eruption, respectively. The class of materials to which most patients reacted positively was contrast medium (n = 53; 41.1%), followed by drugs acting on the central nervous system (n = 18; 28.6%). In the latter group, 16 of the 18 patients were positive to antiepileptics. Positive rates depend on the causative drug rather than the clinical features of the drug eruption. Patch testing is useful when contrast medium or antiepileptics are suspected to be the causative drugs. However, standardization of patch test materials and method of reading is needed, as well as guidelines regarding when testing should be performed. Although patch testing for drug eruption has significant potential, it requires further validation. © 2014 The Authors. Clinical and Experimental Dermatology published by John Wiley & Sons Ltd on behalf of British Association of Dermatologists.

  3. [Where does laparoscopy fit in the treatment of inguinal hernia in 2003?].

    PubMed

    Gainant, A

    2003-06-01

    Meta-analysis of randomized studies has clearly shown that prosthetic repair of inguinal hernias decreases the risk of hernia recurrence when compared with herniorraphy without prosthesis; but the optimal route for insertion of the prosthetic patch (laparoscopic versus open inguinal approach) remains in dispute. Meta-analysis of randomized studies comparing laparoscopic with open prosthetic hernia repair suggest that laparoscopy is associated with less post-operative pain (both early and late), a quicker recovery, and earlier return to work. Yet this is at the price of longer operative time and an incidence of rare but potentially severe complications. On the basis of these randomized studies, the ANAES in France and the NICE in England have put forth recommendations which accept the indication for laparoscopic repair in recurrent and bilateral hernias, if done by surgeons experienced in laparoscopic technique. For unilateral hernia in adults, laparoscopic repair has shown no proof of superiority over open prosthetic repair in terms of mortality, morbidity, or recurrence rate. The principal advantage of the laparoscopic approach seems to be improved patient comfort; its disadvantage is higher cost and technical difficulty with a prolonged learning curve. The excess costs of the laparoscopic approach may be compensated by an earlier return to work. At present, the laparoscopic repair of hernias finds its clinical niche in patients with bilateral or recurrent hernias or in patients with unilateral hernia who desire a minimal period of postoperative disability.

  4. Evaluation of Repair Efficiency in Structures Made of Fibrous Polymer Composite Materials

    NASA Astrophysics Data System (ADS)

    Anoshkin, A. N.; Vil'deman, V. E.; Lobanov, D. S.; Chikhachev, A. I.

    2014-07-01

    Full-scale experimental investigations into the residual strength of structurally similar elements of acoustical panels after a local repair of defects, such as through breakdown, were conducted. Local repairs without using the vacuum technology were carried out. The technology of repair consists in removing and layer-bylayer replacing the damaged layers of material with repaired ones. For comparison, undamaged and repaired sandwich panel specimens were tested in tension and compression. The specimens were produced by serial technology from a VPS-33 fiberglass prepreg. Their deformation and fracture mechanisms are analyzed, and their loading diagrams are obtained.

  5. Transparent solar antenna of 28 GHz using transparent conductive oxides (TCO) thin film

    NASA Astrophysics Data System (ADS)

    Ali, N. I. Mohd; Misran, N.; Mansor, M. F.; Jamlos, M. F.

    2017-05-01

    This paper presents the analysis of 28GHz solar patch antenna using the variations of transparent conductive oxides (TCO) thin film as the radiating patch. Solar antenna is basically combining the function of antenna and solar cell into one device and helps to maximize the usage of surface area. The main problem of the existing solar antenna is the radiating patch which made of nontransparent material, such as copper, shadowing the solar cell and degrades the total solar efficiency. Hence, by using the transparent conductive oxides (TCO) thin film as the radiating patch, this problem can be tackled. The TCO thin film used is varied to ITO, FTO, AgHT-4, and AgHT-8 along with glass as substrate. The simulation of the antenna executed by using Computer Simulation Technology (CST) Microwave Studio software demonstrated at 28 GHz operating frequency for 5G band applications. The performance of the transparent antennas is compared with each other and also with the nontransparent patch antenna that using Rogers RT5880 as substrate, operating at the same resonance frequency and then, the material that gives the best performance is identified.

  6. Cinnamic aldehyde: a survey of consumer patch-test sensitization.

    PubMed

    Danneman, P J; Booman, K A; Dorsky, J; Kohrman, K A; Rothenstein, A S; Sedlak, R I; Steltenkamp, R J; Thompson, G R

    1983-12-01

    The potential for cinnamic aldehyde, an important fragrance and flavour ingredient, to induce or to elicit delayed contact hypersensitivity reactions in man was evaluated by analysing patch-test data. Results of studies involving a total of 4117 patch tests on various consumer products and fragrance blends containing cinnamic aldehyde and on the material itself were collected from fragrance and formulator companies. The data indicate that cinnamic aldehyde contained in consumer products and fragrance blends at concentrations up to 6 X 10(-1)%, and patch-tested at concentrations up to 8 X 10(-3)%, has no detectable potential to induce hypersensitivity. Cinnamic aldehyde when tested alone induced a dose-related hypersensitivity response. According to published reports, cinnamic aldehyde elicited positive delayed hypersensitivity responses in dermatitic patients. However, results of the current survey show that when cinnamic aldehyde was tested alone or as part of a mixture in subjects in the general population, no pre-existing hypersensitivity reactions to the fragrance material were observed in any of the 4117 patch tests which constituted the survey. Cinnamic aldehyde at the concentrations contained in consumer products and fragrances, has a very low potential to induce hypersensitivity ('induced' reactions) or to elicit sensitization reactions ('elicited' reactions) in the general population.

  7. In Vitro Comparison of the Bond Strength between Ceramic Repair Systems and Ceramic Materials and Evaluation of the Wettability.

    PubMed

    Kocaağaoğlu, Hasan; Manav, Taha; Albayrak, Haydar

    2017-04-01

    When fracture of an all-ceramic restoration occurs, it can be necessary to repair without removing the restoration. Although there are many studies about the repair of metal-ceramic restorations, there are few about all-ceramic restorations. The aim of this study was to evaluate the shear bond strength between ceramic repair systems and esthetic core materials and to evaluate the wettability of all-ceramic core materials. Disk-like specimens (N = 90) made of three dental ceramic infrastructure materials (zirconia ceramic, alumina ceramic, glass ceramic) were polished with silicon carbide paper, prepared for bonding (abrasion with 30 μm diamond rotary cutting instrument). Thirty specimens of each infrastructure were obtained. Each infrastructure group was divided into three subgroups; they were bonded using 3 repair systems: Bisco Intraoral Repair Kit, Cimara & Cimara Zircon Repair System, and Clearfil Repair System. After 1200 thermocycles, shear bond strength was measured in a universal testing machine at a 0.5 mm/min crosshead speed. In addition, the contact angle values of the infrastructures after surface treatments were examined for wettability. Data were analyzed by using ANOVA and Tukey post hoc tests. Although there were no significant differences among the repair systems (p > 0.05) in the glass ceramic and zirconia groups, a significant difference was found among the repair systems in alumina infrastructure (p < 0.001). There were no statistically significant differences among the infrastructures (p > 0.05); however, a statistically significant difference was found among the repair systems (p < 0.05). No difference was found among the infrastructures and repair systems in terms of contact angle values. Cimara & Cimara Zircon Repair System had higher bond strength values than the other repair systems. Although no difference was found among the infrastructures and repair systems, contact wettability angle was decreased by surface treatments compared with polished surfaces. © 2015 by the American College of Prosthodontists.

  8. The Role of Airborne Proteins in Atopic Dermatitis

    PubMed Central

    Hostetler, Sarah Grim; Kaffenberger, Benjamin; Hostetler, Todd

    2010-01-01

    Atopic dermatitis is a common, chronic skin condition. A subpopulation of patients may have cutaneous exposure to common airborne proteins exacerbating their disease through direct proteolytic activity, direct activation of proteinase-activated receptor-2 itch receptors, and immunoglobulin E binding. The most common airborne proteins significant in atopic dermatitis include house dust mites, cockroach, pet dander, and multiple pollens. The literature on atopy patch testing, skin-prick testing, and specific IgE is mixed, with greater support for the use of atopy patch test. Patients with airborne proteins contributing to their disease typically have lesions predominately on air-exposed skin surfaces including the face, neck, and arms; a history of exacerbations after exposure to airborne proteins; severe disease resistant to conventional therapies; and concurrent asthma. Treatment strategies include airborne protein avoidance, removal of airborne proteins from the skin, and barrier repair. Further research is needed to establish the benefit of allergen-specific immunotherapy. PMID:20725535

  9. "It is about how the net looks": a qualitative study of perceptions and practices related to mosquito net care and repair in two districts in eastern Uganda.

    PubMed

    Scandurra, Leah; Acosta, Angela; Koenker, Hannah; Kibuuka, Daniel Musoke; Harvey, Steven

    2014-12-17

    Prolonging net durability has important implications for reducing both malaria transmission and the frequency of net replacement. Protective behaviour, such as net care and repair, offers promise for improving net integrity and durability. Given the potential cost-savings and public health benefit associated with extending the useful life of long-lasting insecticidal nets (LLINs), prevention and mitigation of damage will become ever more critical to ensuring adequate net coverage at the population level. A qualitative assessment was conducted in two districts in central eastern Uganda in September 2013. Data on household net care and repair behaviour, attitudes and practices were collected from 30 respondents through in-depth interviews (IDIs), observations, photos, and video to gather an in-depth understanding of these behaviours. Net damage was common and the most cited causes were children and rodents. Responses revealed strong social norms about net cleanliness and aesthetics, and strong expectations that others should care for and repair their own nets. Respondents were receptive and able to repair nets, though longer-term repair methods, such as sewing and patching, were not as commonly reported or observed. Self-reported behaviour was not always consistent with observed or demonstrated behaviour, revealing potential misconceptions and the need for clear and consistent net care and repair messaging. Respondents considered both aesthetics and malaria protection important when deciding whether, when, and how to care for and repair nets. BCC should continue to emphasize the importance of maintaining net integrity for malaria prevention purposes as well as for maintaining aesthetic appeal. Additional research is needed, particularly surrounding washing, drying, daily storage routines, and gender roles in care and repair, in order to understand the complexity of these behaviours, and refine existing or develop new behaviour change communication (BCC) messages for net care and repair.

  10. The Application of Fiber-Reinforced Materials in Disc Repair

    PubMed Central

    Pei, Bao-Qing; Li, Hui; Zhu, Gang; Li, De-Yu; Fan, Yu-Bo; Wu, Shu-Qin

    2013-01-01

    The intervertebral disc degeneration and injury are the most common spinal diseases with tremendous financial and social implications. Regenerative therapies for disc repair are promising treatments. Fiber-reinforced materials (FRMs) are a kind of composites by embedding the fibers into the matrix materials. FRMs can maintain the original properties of the matrix and enhance the mechanical properties. By now, there are still some problems for disc repair such as the unsatisfied static strength and dynamic properties for disc implants. The application of FRMs may resolve these problems to some extent. In this review, six parts such as background of FRMs in tissue repair, the comparison of mechanical properties between natural disc and some typical FRMs, the repair standard and FRMs applications in disc repair, and the possible research directions for FRMs' in the future are stated. PMID:24383057

  11. Dexpanthenol enhances skin barrier repair and reduces inflammation after sodium lauryl sulphate-induced irritation.

    PubMed

    Proksch, E; Nissen, H P

    2002-12-01

    Dexpanthenol-containing creams have been widely used for treatment of lesions (superficial wounds) of the skin and mucous membranes. Dexpanthenol is converted in tissues to pantothenic acid, a component of coenzyme A. Coenzyme A catalyses early steps in the synthesis of fatty acids and sphingolipids which are of crucial importance for stratum corneum lipid bilayers and cell membrane integrity. In the present study, the effects were examined of a dexpanthenol-containing cream on skin barrier repair, stratum corneum hydration, skin roughness, and inflammation after sodium lauryl sulphate (SLS)-induced irritation. Irritation was induced by application of SLS in patch test chambers. The dexpanthenol-contaming cream or the vehicle were applied twice daily and barrier repair, hydration, roughness, and inflammation of the skin were determined by using biophysical methods. Significantly accelerated skin barrier repair was found in treatments with the dexpanthenol-containing cream (verum) compared with vehicle-treated (placebo) or untreated skin. Both verum and placebo showed an increase in stratum corneum hydration, but significantly more so with the dexpanthenol-containing cream. Both creams reduced skin roughness, but again the verum was superior. The dexpanthenol-containing cream significantly reduced skin redness as a sign of inflammation in contrast to the vehicle, which produced no effect. Treatment with a dexpanthenol-containing cream showed significantly enhanced skin barrier repair and stratum corneum hydration, while reducing skin roughness and inflammation.

  12. Sensitization to fragrance materials in Indonesian cosmetics.

    PubMed

    Roesyanto-Mahadi, I D; Geursen-Reitsma, A M; van Joost, T; van den Akker, T W

    1990-04-01

    2 different groups of patients were patch tested with 2 test series (A and B) containing extracts of fragrance raw materials, traditionally used in Indonesian cosmetics. Series A consisted of diluted extracts of commercially available Indonesian fragrances. Series B consisted of extracts prepared in our department from corresponding indigenous flowers and fruits. Group 1 consisted of 32 patients positive to fragrance-mix, of whom 8 (25%) had positive tests to 1 or more of the different extracts of fragrance raw materials. Reactions were observed to extracts of: Rosa hybrida Hort (7); Canangium odoratum Baill (5); Citrus aurantifolia Swingle (4); Jasminum sambac Ait (2). 6 of the 8 patients had reactions to 1 or more of the components of fragrance-mix: oakmoss (3); cinnamic alcohol (2), isoeugenol (1); cinnamic aldehyde (1) and geraniol (1). Group 2 consisted of 159 patients patch tested on suspicion of contact dermatitis, who were fragrance-mix negative. Only 2 (1.2%) had a positive patch test to the extracts of fragrance raw materials. Specimens taken (as is) from the flowers and citrus fruits (being the basis sources of the fragrance raw materials) were less antigenic. The use of additional test series in Indonesia to detect allergy to traditional cosmetics and perfumes merits further investigation.

  13. New Variable Porosity Flow Diverter (VPOD) Stent Design for Treatment of Cerebrovascular Aneurysms

    PubMed Central

    Ionita, Ciprian; Baier, Robert; Rudin, Stephen

    2012-01-01

    Using flow diverting Stents for intracranial aneurysm repair has been an area of recent active research. While current commercial flow diverting stents rely on a dense mesh of braided coils for flow diversion, our group has been developing a method to selectively occlude the aneurysm neck, without endangering nearby perforator vessels. In this paper, we present a new method of fabricating the low porosity patch, a key element of such asymmetric vascular stents (AVS). PMID:22254507

  14. Finite Element and Analytical Analysis of Cracks in Thick Stiffened Plates Repaired with a Single Sided Composite Patch

    DTIC Science & Technology

    2014-06-01

    DC,Tech. Rep. CG-D-05–00, 2000. [16] S. Kou, Welding Metallurgy , 2nd edition, Hoboken: Wiley Interscience, 2003. [17] C. Poe, “Stress intensity...continuous aluminum superstructure welded to the deck. The shape of the superstructure created numerous stress concentration areas. Of the greatest concern...study as it will help provide a conservative estimate. In marine applications almost all stiffening members are attached by welding . Unlike a

  15. Vision inspection system and method

    NASA Technical Reports Server (NTRS)

    Huber, Edward D. (Inventor); Williams, Rick A. (Inventor)

    1997-01-01

    An optical vision inspection system (4) and method for multiplexed illuminating, viewing, analyzing and recording a range of characteristically different kinds of defects, depressions, and ridges in a selected material surface (7) with first and second alternating optical subsystems (20, 21) illuminating and sensing successive frames of the same material surface patch. To detect the different kinds of surface features including abrupt as well as gradual surface variations, correspondingly different kinds of lighting are applied in time-multiplexed fashion to the common surface area patches under observation.

  16. Comparison of hemostatic properties between collagen and synthetic buttress materials used in staple line reinforcement in a swine splenic hemorrhage model.

    PubMed

    Spector, David; Perry, Zvi; Konobeck, Tracy; Mooradian, Daniel; Shikora, Scott

    2011-04-01

    The use of staplers in gastrointestinal surgery is widespread, especially in advanced laparoscopic procedures. Staple line reinforcement with a buttress reduces bleeding and associated complications through a combination of factors. The intrinsic hemostatic properties of buttress materials have not been examined. This study examined the intrinsic hemostatic properties of two different types of material used in buttressing in an accepted hemostasis model that does not involve stapling or its effects by compression. An acellular collagen buttress (Veritas) and a synthetic polymer buttress (Duet) were compared to two commonly used hemostatic agents, Syvek and Surgicel, with gauze as control. In a swine capsular stripping hemostasis model, a 1 × 1 cm section of spleen capsule was removed and used as a source of bleeding, with one patch of material tested per bleeding site. A total of 51 wounds were created in five pigs (each patch n = 10, control n = 11). Hemostatic efficacy was assessed by quantitating the number of applications and total time needed for bleeding to stop. The mean time needed for hemostasis for Syvek and Veritas patches was significantly less than gauze, Duet and Surgicel (4.02, 4.51 vs. 8.97, 9.22, and 10.30 min respectively; p < 0.05). The Syvek and Veritas patches required significantly fewer applications than gauze, Duet™ and Surgicel (1.7, 2.2 vs. 4.1, 4.6, and 4.9 respectively; p < 0.01). The intrinsic hemostatic properties of different buttressing materials vary widely. In this study, a collagen buttress was significantly better at promoting hemostasis than the synthetic buttress material in a nonstapling model. This could be another factor to consider when choosing a buttress for staple line reinforcement.

  17. Biodegradable Materials for Bone Repair and Tissue Engineering Applications

    PubMed Central

    Sheikh, Zeeshan; Najeeb, Shariq; Khurshid, Zohaib; Verma, Vivek; Rashid, Haroon; Glogauer, Michael

    2015-01-01

    This review discusses and summarizes the recent developments and advances in the use of biodegradable materials for bone repair purposes. The choice between using degradable and non-degradable devices for orthopedic and maxillofacial applications must be carefully weighed. Traditional biodegradable devices for osteosynthesis have been successful in low or mild load bearing applications. However, continuing research and recent developments in the field of material science has resulted in development of biomaterials with improved strength and mechanical properties. For this purpose, biodegradable materials, including polymers, ceramics and magnesium alloys have attracted much attention for osteologic repair and applications. The next generation of biodegradable materials would benefit from recent knowledge gained regarding cell material interactions, with better control of interfacing between the material and the surrounding bone tissue. The next generations of biodegradable materials for bone repair and regeneration applications require better control of interfacing between the material and the surrounding bone tissue. Also, the mechanical properties and degradation/resorption profiles of these materials require further improvement to broaden their use and achieve better clinical results. PMID:28793533

  18. Stretchable and reversibly deformable radio frequency antennas based on silver nanowires.

    PubMed

    Song, Lingnan; Myers, Amanda C; Adams, Jacob J; Zhu, Yong

    2014-03-26

    We demonstrate a class of microstrip patch antennas that are stretchable, mechanically tunable, and reversibly deformable. The radiating element of the antenna consists of highly conductive and stretchable material with screen-printed silver nanowires embedded in the surface layer of an elastomeric substrate. A 3-GHz microstrip patch antenna and a 6-GHz 2-element patch array are fabricated. Radiating properties of the antennas are characterized under tensile strain and agree well with the simulation results. The antenna is reconfigurable because the resonant frequency is a function of the applied tensile strain. The antenna is thus well suited for applications like wireless strain sensing. The material and fabrication technique reported here could be extended to achieve other types of stretchable antennas with more complex patterns and multilayer structures.

  19. Induction and differentiation of human induced pluripotent stem cells into functional cardiomyocytes on a compartmented monolayer of gelatin nanofibers

    NASA Astrophysics Data System (ADS)

    Tang, Yadong; Liu, Li; Li, Junjun; Yu, Leqian; Wang, Li; Shi, Jian; Chen, Yong

    2016-07-01

    Extensive efforts have been devoted to develop new substrates for culture and differentiation of human induced pluripotent stem cells (hiPSCs) toward cardiac cell-based assays. A more exciting prospect is the construction of cardiac tissue for robust drug screening and cardiac tissue repairing. Here, we developed a patch method by electrospinning and crosslinking of monolayer gelatin nanofibers on a honeycomb frame made of poly(ethylene glycol) diacrylate (PEGDA). The monolayer of the nanofibrous structure can support cells with minimal exogenous contact and a maximal efficiency of cell-medium exchange whereas a single hiPSC colony can be uniformly formed in each of the honeycomb compartments. By modulating the treatment time of the ROCK inhibitor Y-27632, the shape of the hiPSC colony could be controlled from a flat layer to a hemisphere. Afterwards, the induction and differentiation of hiPSCs were achieved on the same patch, leading to a uniform cardiac layer with homogeneous contraction. This cardiac layer could then be used for extracellular recording with a commercial multi-electrode array, showing representative field potential waveforms of matured cardiac tissues with appropriate drug responses.Extensive efforts have been devoted to develop new substrates for culture and differentiation of human induced pluripotent stem cells (hiPSCs) toward cardiac cell-based assays. A more exciting prospect is the construction of cardiac tissue for robust drug screening and cardiac tissue repairing. Here, we developed a patch method by electrospinning and crosslinking of monolayer gelatin nanofibers on a honeycomb frame made of poly(ethylene glycol) diacrylate (PEGDA). The monolayer of the nanofibrous structure can support cells with minimal exogenous contact and a maximal efficiency of cell-medium exchange whereas a single hiPSC colony can be uniformly formed in each of the honeycomb compartments. By modulating the treatment time of the ROCK inhibitor Y-27632, the shape of the hiPSC colony could be controlled from a flat layer to a hemisphere. Afterwards, the induction and differentiation of hiPSCs were achieved on the same patch, leading to a uniform cardiac layer with homogeneous contraction. This cardiac layer could then be used for extracellular recording with a commercial multi-electrode array, showing representative field potential waveforms of matured cardiac tissues with appropriate drug responses. Electronic supplementary information (ESI) available. See DOI: 10.1039/c6nr04545f

  20. Bond Strength Mechanism of Fly Ash Based Geopolymer Mortars: A Review

    NASA Astrophysics Data System (ADS)

    Zailani, W. W. A.; Abdullah, M. M. A. B.; Razak, R. A.; Zainol, M. R. R. M. A.; Tahir, M. F. M.

    2017-11-01

    Geopolymer possess many excellent properties such as high compressive and bond strength, long term durability, better acid resistance and also known as a “Sustainable Material” due to its low carbon emission and low energy consumption. Thus, it is a good opportunity to develop and explore not only for cement and concrete but also as geopolymeric repair materials. This reviews showed that good bonding properties between geopolymeric repair material and concrete substrate is important in order to acquire an enhanced resistance against penetration of harmful substances and avoiding respalling of the repair material by understanding the bonding behaviour. Bond strength depends to the properties of the repair materials itself and also the surface preparations of concrete substrate.

  1. Response of bed surface patchiness to reductions in sediment supply

    NASA Astrophysics Data System (ADS)

    Nelson, Peter A.; Venditti, Jeremy G.; Dietrich, William E.; Kirchner, James W.; Ikeda, Hiroshi; Iseya, Fujiko; Sklar, Leonard S.

    2009-06-01

    River beds are often arranged into patches of similar grain size and sorting. Patches can be distinguished into "free patches," which are zones of sorted material that move freely, such as bed load sheets; "forced patches," which are areas of sorting forced by topographic controls; and "fixed patches" of bed material rendered immobile through localized coarsening that remain fairly persistent through time. Two sets of flume experiments (one using bimodal, sand-rich sediment and the other using unimodal, sand-free sediment) are used to explore how fixed and free patches respond to stepwise reductions in sediment supply. At high sediment supply, migrating bed load sheets formed even in unimodal, sand-free sediment, yet grain interactions visibly played a central role in their formation. In both sets of experiments, reductions in supply led to the development of fixed coarse patches, which expanded at the expense of finer, more mobile patches, narrowing the zone of active bed load transport and leading to the eventual disappearance of migrating bed load sheets. Reductions in sediment supply decreased the migration rate of bed load sheets and increased the spacing between successive sheets. One-dimensional morphodynamic models of river channel beds generally are not designed to capture the observed variability, but should be capable of capturing the time-averaged character of the channel. When applied to our experiments, a 1-D morphodynamic model (RTe-bookAgDegNormGravMixPW.xls) predicted the bed load flux well, but overpredicted slope changes and was unable to predict the substantial variability in bed load flux (and load grain size) because of the migration of mobile patches. Our results suggest that (1) the distribution of free and fixed patches is primarily a function of sediment supply, (2) the dynamics of bed load sheets are primarily scaled by sediment supply, (3) channels with reduced sediment supply may inherently be unable to transport sediment uniformly across their width, and (4) cross-stream variability in shear stress and grain size can produce potentially large errors in width-averaged sediment flux calculations.

  2. 29 CFR 1915.57 - Uses of fissionable material in ship repairing and shipbuilding.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 7 2012-07-01 2012-07-01 false Uses of fissionable material in ship repairing and shipbuilding. 1915.57 Section 1915.57 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND... and shipbuilding. The provisions of this section apply to ship repairing and shipbuilding only. (a) In...

  3. 29 CFR 1915.57 - Uses of fissionable material in ship repairing and shipbuilding.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 7 2011-07-01 2011-07-01 false Uses of fissionable material in ship repairing and shipbuilding. 1915.57 Section 1915.57 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND... and shipbuilding. The provisions of this section apply to ship repairing and shipbuilding only. (a) In...

  4. 29 CFR 1915.57 - Uses of fissionable material in ship repairing and shipbuilding.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 7 2014-07-01 2014-07-01 false Uses of fissionable material in ship repairing and shipbuilding. 1915.57 Section 1915.57 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND... and shipbuilding. The provisions of this section apply to ship repairing and shipbuilding only. (a) In...

  5. 29 CFR 1915.57 - Uses of fissionable material in ship repairing and shipbuilding.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 7 2013-07-01 2013-07-01 false Uses of fissionable material in ship repairing and shipbuilding. 1915.57 Section 1915.57 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND... and shipbuilding. The provisions of this section apply to ship repairing and shipbuilding only. (a) In...

  6. In-Space Repair of Reinforced Carbon-Carbon Thermal Protection System Structures

    NASA Technical Reports Server (NTRS)

    Singh, Mrityunjay

    2006-01-01

    Advanced repair and refurbishment technologies are critically needed for the thermal protection system of current space transportation system as well as for future Crew Exploration Vehicles (CEV). The damage to these components could be caused by impact during ground handling or due to falling of ice or other objects during launch. In addition, in-orbit damage includes micrometeoroid and orbital debris impact as well as different factors (weather, launch acoustics, shearing, etc.) during launch and re-entry. The GRC developed GRABER (Glenn Refractory Adhesive for Bonding and Exterior Repair) material has shown multiuse capability for repair of small cracks and damage in reinforced carbon-carbon (RCC) material. The concept consists of preparing an adhesive paste of desired ceramic with appropriate additives and then applying the paste to the damaged/cracked area of the RCC composites with adhesive delivery system. The adhesive paste cures at 100-120 C and transforms into a high temperature ceramic during simulated entry conditions. A number of plasma torch and ArcJet tests were carried out to evaluate the crack repair capability of GRABER materials for Reinforced Carbon-Carbon (RCC) composites. For the large area repair applications, integrated system for tile and leading edge repair (InSTALER) have been developed. In this presentation, critical in-space repair needs and technical challenges as well as various issues and complexities will be discussed along with the plasma performance and post test characterization of repaired RCC materials.

  7. In-Space Repair and Refurbishment of Thermal Protection System Structures for Reusable Launch Vehicles

    NASA Technical Reports Server (NTRS)

    Singh, M.

    2007-01-01

    Advanced repair and refurbishment technologies are critically needed for the thermal protection system of current space transportation systems as well as for future launch and crew return vehicles. There is a history of damage to these systems from impact during ground handling or ice during launch. In addition, there exists the potential for in-orbit damage from micrometeoroid and orbital debris impact as well as different factors (weather, launch acoustics, shearing, etc.) during launch and re-entry. The GRC developed GRABER (Glenn Refractory Adhesive for Bonding and Exterior Repair) material has shown multiuse capability for repair of small cracks and damage in reinforced carbon-carbon (RCC) material. The concept consists of preparing an adhesive paste of desired ceramic with appropriate additives and then applying the paste to the damaged/cracked area of the RCC composites with an adhesive delivery system. The adhesive paste cures at 100-120 C and transforms into a high temperature ceramic during reentry conditions. A number of plasma torch and ArcJet tests were carried out to evaluate the crack repair capability of GRABER materials for Reinforced Carbon-Carbon (RCC) composites. For the large area repair applications, Integrated Systems for Tile and Leading Edge Repair (InSTALER) have been developed and evaluated under various ArcJet testing conditions. In this presentation, performance of the repair materials as applied to RCC is discussed. Additionally, critical in-space repair needs and technical challenges are reviewed.

  8. Environmental contact factors in eczema and the results of patch testing Chinese patients with a modified European standard series of allergens.

    PubMed

    Li, Lin-Feng; Guo, Jing; Wang, Jing

    2004-07-01

    Environmental contact factors in eczema were investigated in China by clinical questionnaire and patch testing patients with a modified European standard series of allergens. 217 consecutive eczema patients were studied. Contact dermatitis (CD) was clinically diagnosed in 30% of the patients. Among the patients patch tested, 46 patients had clinically diagnosed allergic CD (ACD), 20 patients clinically had non-ACD (NACD) (including 16 cases of irritant contact dermatitis, 1 case of phototoxic contact reaction and 3 cases of asteatotic eczema) and 115 patients had clinically suspected ACD. 45 patients (98%) in the ACD group went on to have relevant patch test results. The most common ACD was from metals, fragrance materials, cosmetics and rubber materials. The most common contact allergens identified were nickel, fragrance mix, para-phenylenediamine (PPD), carba mix and thimerosal. No adverse reactions were observed to patch testing, except for pruritus in patch-test-positive patients. The positive rate of patch testing in ACD was much higher than that in NACD (98% versus 15%, P < 0.05, chi(2)-test). 60 (28%) patients had facial dermatitis (FD). Among these, 20 (33%) were confirmed as having ACD. 48 (22%) patients had hand dermatitis (HD). Among these, 7 (15%) were confirmed as having ACD. Fewer patients were confirmed as having ACD in the HD group than in the FD (15% versus 33%, P < 0.05, chi(2)-test). Although the difference was not significant, the total positivity rate in the HD group (55%) was lower than in the other groups. 65 (30%) patients had unclassified endogenous eczema (UEE). The total positive rate of patch testing in the UEE group (56%) was no different from that in the FD or HD groups. However, the relevance of positive patch tests was hard to determine in UEE. These results indicate that CD is common in eczema; relatively more patients with FD have ACD, while other factors, such as irritation, may play more of a role in HD. The total positive rate of patch testing in the UEE group was no different from that in the FD or HD groups, suggesting that patch testing should be stressed in UEE and the relevance of positive patch test results in UEE should be studied further. It is effective and safe to patch eczema patients with a modified European standard series of allergens in China.

  9. Evidence for a Role of FEN1 in Maintaining Mitochondrial DNA Integrity

    PubMed Central

    Kalifa, Lidza; Beutner, Gisela; Phadnis, Naina; Sheu, Shey-Shing; Sia, Elaine A.

    2009-01-01

    Although the nuclear processes responsible for genomic DNA replication and repair are well characterized, the pathways involved in mitochondrial DNA (mtDNA) replication and repair remain unclear. DNA repair has been identified as being particularly important within the mitochondrial compartment due to the organelle’s high propensity to accumulate oxidative DNA damage. It has been postulated that continual accumulation of mtDNA damage and subsequent mutagenesis may function in cellular aging. Mitochondrial base excision repair (mtBER) plays a major role in combating mtDNA oxidative damage; however, the proteins involved in mtBER have yet to be fully characterized. It has been established that during nuclear long-patch (LP) BER, FEN1 is responsible for cleavage of 5′ flap structures generated during DNA synthesis. Furthermore, removal of 5′ flaps has been observed in mitochondrial extracts of mammalian cell lines; yet, the mitochondrial localization of FEN1 has not been clearly demonstrated. In this study, we analyzed the effects of deleting the yeast FEN1 homolog, RAD27, on mtDNA stability in Saccharomyces cerevisiae. Our findings demonstrate that Rad27p/FEN1 is localized in the mitochondrial compartment of both yeast and mice and that Rad27p has a significant role in maintaining mtDNA integrity. PMID:19699691

  10. Results of patch testing in 10 patients with peristomal dermatitis.

    PubMed

    Landis, Megan N; Keeling, James H; Yiannias, James A; Richardson, Donna M; Nordberg Linehan, Diane L; Davis, Mark D P

    2012-09-01

    Peristomal dermatitis is a common problem in patients with ostomies that is a source of considerable morbidity. Irritant contact dermatitis is most common, but allergic contact dermatitis can also occur. Because of the lack of published reports on patch testing for this indication, we undertook a retrospective study of patch testing results in patients with suspected peristomal allergic contact dermatitis. We sought to describe our patch testing experience with patients referred with peristomal dermatitis. This was a retrospective review of medical records of patients with ostomies and peristomal dermatitis who underwent patch testing in the Mayo Clinic Departments of Dermatology in Jacksonville, FL; Rochester, MN; and Scottsdale, AZ, during a 10-year period (2000-2010). Ten patients with peristomal dermatitis were referred for patch testing (6 in Minnesota, 2 in Florida, and 2 in Arizona). Patients were patch tested to the materials used in their stoma devices, to the standard series, and in some cases to supplemental series. All 10 had at least one allergic patch test reaction, most commonly to stoma paste (3 of 10 patients). Retrospective nature of study via chart review is a limitation. Patch testing is a useful tool for identification of allergens in patients with peristomal dermatitis. Copyright © 2011 American Academy of Dermatology, Inc. Published by Mosby, Inc. All rights reserved.

  11. Cold Spray Repair of Martensitic Stainless Steel Components

    NASA Astrophysics Data System (ADS)

    Faccoli, M.; Cornacchia, G.; Maestrini, D.; Marconi, G. P.; Roberti, R.

    2014-12-01

    The possibility of using cold spray as repair technique of martensitic stainless steel components was evaluated through laboratory investigations. An austenitic stainless steel feedstock powder was chosen, instead of soft metals powders like nickel, copper, or aluminum, used for repairing components made in light alloy or cast iron. The present study directly compares the microstructure, the residual stresses, and the micro-hardness of repairs obtained by cold spray and by TIG welding, that is commonly used as repair technique in large steel components. XRD and optical metallographic analysis of the repairs showed that cold spray offers some advantages, inducing compressive residual stresses in the repair and avoiding alterations of the interface between repair and base material. For these reasons, a heat treatment after the cold spray repair is not required to restore the base material properties, whereas a post-weld heat treatment is needed after the welding repair. Cold spray repair also exhibits a higher micro-hardness than the welding repair. In addition, the cavitation erosion resistance of a cold spray coating was investigated through ultrasonic cavitation tests, and the samples worn surfaces were observed by scanning electron microscopy.

  12. Non-Intrusive, Distributed Gas Sensing Technology for Advanced Spacesuits

    NASA Technical Reports Server (NTRS)

    Delgado, Jesus; Phillips, Straun; Rubtsov, Vladimir; Chullen, Cinda

    2015-01-01

    Chemical sensors for monitoring gas composition, including oxygen, humidity, carbon dioxide, and trace contaminants are needed to characterize and validate spacesuit design and operating parameters. This paper reports on the first prototypes of a non-intrusive gas sensing technology based on flexible sensitive patches positioned inside spacesuit prototypes and interrogated by optical fibers routed outside the suit, taking advantage of the transparent materials of the suit prototypes. The sensitive patches are based on luminescent materials whose emission parameters vary with the partial pressure of a specific gas. Patches sensitive to carbon dioxide, humidity, oxygen, and ammonia have been developed, and their preliminary characterization in the laboratory using Mark III-like helmet parts is described. The first prototype system consists of a four-channel fiber optic luminescent detector that can be used to monitor any of the selected target gases at four locations. To switch from one gas to another we replace the (disposable) sensor patches and adjust the system settings. Repeatability among sensitive patches and of sensor performance from location to location has been confirmed, assuring that suit engineers will have flexibility in selecting multiple sensing points, fitting the sensor elements into the spacesuit, and easily repositioning the sensor elements as desired. The evaluation of the first prototype for monitoring carbon dioxide during washout studies in a space suit prototype is presented.

  13. Non-Intrusive, Distributed Gas Sensing Technology for Advanced Spacesuits

    NASA Technical Reports Server (NTRS)

    Delgado, Jesus; Phillips, Straun; Rubtsov, Vladimir; Chullen, Cinda

    2015-01-01

    Chemical sensors for monitoring gas composition, including oxygen, humidity, carbon dioxide, and trace contaminants, are needed to characterize and validate spacesuit design and operating parameters. This paper reports on the first prototypes of a non-intrusive gas sensing technology based on flexible sensitive patches positioned inside spacesuit prototypes and interrogated via optical fibers routed outside the suit, taking advantage of the transparent materials of the suit prototypes. The sensitive patches are based on luminescent materials whose emission parameters vary with the partial pressure of a specific gas. Patches sensitive to carbon dioxide, humidity, and temperature have been developed, and their preliminary laboratory characterization in Mark III-like helmet parts is described. The first prototype system consists of a four-channel fiber optic luminescent detector that can be used to monitor any of the selected target gases at four locations. To switch from one gas to another we replace the (disposable) sensor patches and adjust the system settings. Repeatability among sensitive patches and of sensor performance from location to location has been confirmed, assuring that suit engineers will have flexibility in selecting multiple sensing points, fitting the sensor elements into the spacesuit, and easily repositioning the sensor elements as desired. The evaluation of the first prototype for monitoring carbon dioxide during washout studies in a spacesuit prototype is presented.

  14. Epoxy-based production of wind turbine rotor blades: occupational contact allergies.

    PubMed

    Pontén, Ann; Carstensen, Ole; Rasmussen, Kurt; Gruvberger, Birgitta; Isaksson, Marléne; Bruze, Magnus

    2004-03-01

    An industry producing rotor blades for wind turbines with an epoxy-based technology had experienced an increasing number of workers with dermatitis, among whom the frequency of occupational contact allergy (OCA) was suspected to be underestimated. To investigate the frequency of OCA by patch-testing with a specially profiled occupational patch test series. In a blinded study design, 603 workers were first interviewed and thereafter clinically examined. Based on a history of work-related skin disease, clinical findings of dermatitis, or both, 325 (53.9%) of the workers were patch-tested with an occupational patch test series and the European Standard patch test series. Of the 603 investigated workers, 10.9% had OCA and 5.6% had contact allergy to epoxy resin in the standard test series. Contact allergy to amine hardeners/catalysts was found in 4.1% of the workers. Among the workers with OCA, 48.5% reacted to work material other than epoxy resin in the European Standard patch test series. Approximately 50% of the workers with OCA would not have been detected if only the European Standard patch test series had been used.

  15. Micromolded PDMS planar electrode allows patch clamp electrical recordings from cells.

    PubMed

    Klemic, Kathryn G; Klemic, James F; Reed, Mark A; Sigworth, Fred J

    2002-06-01

    The patch clamp method measures membrane currents at very high resolution when a high-resistance 'gigaseal' is established between the glass microelectrode and the cell membrane (Pflugers Arch. 391 (1981) 85; Neuron 8 (1992) 605). Here we describe the first use of the silicone elastomer, poly(dimethylsiloxane) (PDMS), for patch clamp electrodes. PDMS is an attractive material for patch clamp recordings. It has low dielectric loss and can be micromolded (Annu. Rev. Mat. Sci. 28 (1998) 153) into a shape that mimics the tip of the glass micropipette. Also, the surface chemistry of PDMS may be altered to mimic the hydrophilic nature of glass (J. Appl. Polym. Sci. 14 (1970) 2499; Annu. Rev. Mat. Sci. 28 (1998) 153), thereby allowing a high-resistance seal to a cell membrane. We present a planar electrode geometry consisting of a PDMS partition with a small aperture sealed between electrode and bath chambers. We demonstrate that a planar PDMS patch electrode, after oxidation of the elastomeric surface, permits patch clamp recording on Xenopus oocytes. Our results indicate the potential for high-throughput patch clamp recording with a planar array of PDMS electrodes.

  16. Early primary repair of tetralogy of fallot in neonates and infants less than four months of age.

    PubMed

    Tamesberger, Melanie I; Lechner, Evelyn; Mair, Rudolf; Hofer, Anna; Sames-Dolzer, Eva; Tulzer, Gerald

    2008-12-01

    The ideal age for correction of tetralogy of Fallot is still under discussion. The aim of this study was to analyze morbidity and mortality in patients who underwent early primary repair of tetralogy of Fallot at the age of less than 4 months and to assess whether neonates, who needed early repair within the first 4 weeks of life, faced an increased risk. From 1995 to 2006, 90 consecutive patients with tetralogy of Fallot and pulmonary stenosis underwent early primary repair. Patient charts were analyzed retrospectively for two groups: group A, 25 neonates younger than 28 days who needed early operation owing to duct-dependent pulmonary circulation or severe hypoxemia; and group B, 65 infants younger than 4 months of age who underwent elective early repair. There was no 30-day mortality; late mortality was 2% after a median follow-up time of 4.7 years. Seven of 88 patients (8%) needed reoperation and twelve of 88 patients (14%) needed reintervention. Groups A and B did not differ significantly in terms of intensive care unit stay, days of mechanical ventilation, overall hospital stay, major or minor complications, or reoperation. Significant differences were found in a more frequent use of a transannular patch (p = 0.045) and more reinterventions (p = 0.046) in group A. Early primary repair of tetralogy of Fallot can be performed safely and effectively in infants younger than 4 months of age and even in neonates younger than 28 days with duct-dependent pulmonary circulation or severe hypoxemia.

  17. Reduced repair capacity of a DNA clustered damage site comprised of 8-oxo-7,8-dihydro-2'-deoxyguanosine and 2-deoxyribonolactone results in an increased mutagenic potential of these lesions

    DOE PAGES

    Cunniffe, Siobhan; O’Neill, Peter; Greenberg, Marc M.; ...

    2014-04-01

    A signature of ionizing radiation is the induction of DNA clustered damaged sites. Non-double strand break (DSB) clustered damage has been shown to compromise the base excision repair pathway, extending the lifetimes of the lesions within the cluster, compared to isolated lesions. This increases the likelihood the lesions persist to replication and thus increasing the mutagenic potential of the lesions within the cluster. Lesions formed by ionizing radiation include 8-oxo-7,8-dihydro-2'-deoxyguanosine (8-oxodGuo) and 2-deoxyribonolactone (dL). dL poses an additional challenge to the cell as it is not repaired by the short-patch base excision repair pathway. Here we show recalcitrant dL repairmore » is reflected in mutations observed when DNA containing it and a proximal 8-oxodGuo is replicated in Escherichia coli. 8-oxodGuo in close proximity to dL on the opposing DNA strand results in an enhanced frequency of mutation of the lesions within the cluster and a 20 base sequence flanking the clustered damage site in an E. coli based plasmid assay. In vitro repair of a dL lesion is reduced when compared to the repair of an abasic (AP) site and a tetrahydrofuran (THF), and this is due mainly to a reduction in the activity of polymerase β, leading to retarded FEN1 and ligase 1 activities. This study has given insights in to the biological effects of clusters containing dL.« less

  18. Rutting Performance of Cold-Applied Asphalt Repair Materials for Airfield Pavements

    DTIC Science & Technology

    2017-06-23

    susceptibility of hot mix asphalt (HMA) using the asphalt pavement analyzer (APA). Designation T340- 10. Washington, DC: American Association of State...ER D C/ G SL T R- 17 -1 0 Rutting Performance of Cold-Applied Asphalt Repair Materials for Airfield Pavements G eo te ch ni ca l a nd S...of Cold-Applied Asphalt Repair Materials for Airfield Pavements Ben C. Cox, John F. Rushing, and Web Floyd Geotechnical and Structures Laboratory

  19. Self-repairing systems based on ionomers and epoxidized natural rubber blends.

    PubMed

    Rahman, Md Arifur; Penco, Maurizio; Peroni, Isabella; Ramorino, Giorgio; Grande, Antonio Mattia; Di Landro, Luca

    2011-12-01

    The development of materials with the ability of intrinsic self-repairing after damage in a fashion resembling that of living tissues has important scientific and technological implications, particularly in relation to cost-effective approaches toward damage management of materials. Natural rubbers with epoxy functional groups in the macromolecular chain (ENR) and ethylene-methacrylic acid ionomers having acid groups partially neutralized with metal ions possess self-repairing behavior following high energy impacts. This research investigates the self-repairing behavior of both ENR and ionomers during ballistic puncture test on the basis of their thermal and mechanical properties. Heterogeneous blending of ionomers and ENR have also been used here as a strategy to tune the thermal and mechanical properties of the materials. Interestingly, blends of sodium ion containing ionomer exhibit complete self-repairing behavior, whereas blends of zinc ion containing ionomer show limited mending. The chemical structure studied by FTIR and thermal analysis shows that both ion content of ionomer and functionality of ENR have significant influence on the self-repairing behavior of blends. The mobility of rubbery phases along with its interaction to ionomer phase in the blends significantly changes the mending capability of materials. The healing behavior of the materials has been discussed on the basis of their thermal, mechanical, and rheological tests for each materials. © 2011 American Chemical Society

  20. [Prevention and repair of patellar ligament injury in total knee arthroplasty].

    PubMed

    Bian, Yanyan; Weng, Xisheng

    2013-09-01

    To review the progress in the prevention and repair of patellar ligament injury in total knee Recent literature about the prevention and repair of patellar ligament injury in total knee arthroplasty arthroplasty. was reviewed and analyzed. Increased exposure can prevent the patellar ligament injury, and treatments of acute patellar ligament rupture can be obtained by simple repair, reconstruction with allograft materials or artificial materials, and auxiliary strengthening. Patellar ligament injury in total knee arthroplasty should not be ignored. Active prevention and repair of patellar ligament injury can obtain better function of knee joint.

  1. Pretreatment of pericardial patches with antibiotics does not alter patch healing in vivo.

    PubMed

    Bai, Hualong; Kuwahara, Go; Wang, Mo; Brownson, Kirstyn E; Foster, Trenton R; Yamamoto, Kota; Xing, Ying; Dardik, Alan

    2016-04-01

    Pretreatment with antibiotics is commonly performed before surgical implantation of prosthetic materials. We previously showed that pericardial patches are infiltrated by macrophages and arterial stem cells after implantation into an artery. We hypothesized that antibiotic pretreatment would diminish the number of cells infiltrating into the patch, potentially affecting early neointimal formation. Bovine pericardial patches were pretreated with saline, bacitracin (500 U/mL), or cephalexin (10 mg/mL) for 30 minutes before implantation into the Wistar rat infrarenal aorta. Patches were retrieved on day 7 or day 30 and analyzed for histology and cell infiltration. Markers of proliferation, apoptosis, vascular cell identity, and M1 and M2 macrophage subtypes were examined using immunofluorescence and immunohistochemistry. Extracted proteins were analyzed by Western blot. At day 7, pericardial patches pretreated with bacitracin or cephalexin showed similar amounts of neointimal thickening (P = .55) and cellular infiltration (P = .42) compared with control patches. Patches pretreated with antibiotics showed similar proliferation (P = .09) and apoptosis (P = .84) as control patches. The cell composition of the neointima in pretreated patches was similar to control patches, with a thin endothelial layer overlying a thin layer of smooth muscle cells (P = .45), and containing similar numbers of CD34-positive (P = .26) and vascular endothelial growth factor receptor 2-positive (P = .31) cells. Interestingly, within the body of the patch, there were fewer macrophages (P = .0003) and a trend towards fewer endothelial progenitor cells (P = .051). No M1 macrophages were found in or around any of the patches. M2 macrophages were present around the patches, and there was no difference in numbers of M2 macrophages surrounding control patches and patches pretreated with antibiotics (P = .24). There was no difference in neointimal thickness at day 30 between control patches and patches pretreated with antibiotics (P = .52). Pretreatment of bovine pericardial patches with the antibiotics bacitracin or cephalexin has no detrimental effect on early patch healing, with similar neointimal thickness, cellular infiltration, and numbers of M2 macrophages compared with control patches. These results suggest that the host vessel response to patch angioplasty using pericardial patches is adaptive remodeling (eg, arterial healing). Published by Elsevier Inc.

  2. Evaluation of New Repair Methods for Seal Surface Defects on Reusable Solid Rocket Motor (RSRM) Hardware

    NASA Technical Reports Server (NTRS)

    Stanley, Stephanie; Selvidge, Shawn

    2003-01-01

    The focus of the evaluation was to develop a back-up method to cell plating for the improvement or repair of seal surface defects within D6-AC steel and 7075-T73 aluminum used in the RSRM program. Several techniques were investigated including thermal and non-thermal based techniques. Ideally the repair would maintain the inherent properties of the substrate without losing integrity at the repair site. The repaired sites were tested for adhesion, corrosion, hardness, microhardness, surface toughness, thermal stability, ability to withstand bending of the repair site, and the ability to endure a high-pressure water blast without compromising the repaired site. The repaired material could not change the inherent properties of the substrate throughout each of the test in order to remain a possible technique to repair the RSRM substrate materials. One repair method, Electro-Spark Alloying, passed all the testing and is considered a candidate for further evaluation.

  3. Evaluation of New Repair Methods for Seal Surface Defects on Reusable Solid Rocket Motor (RSRM) Hardware

    NASA Technical Reports Server (NTRS)

    Stanley, Stephanie D.; Selvidge, Shawn A.; Cash, Steve (Technical Monitor)

    2002-01-01

    The focus of the evaluation was to develop a back-up method to cell plating for the improvement or repair of seal surface defects within D6-AC steel and 7075-T73 aluminum used in the RSRM program. Several techniques were investigated including thermal and non-thermal based techniques. Ideally the repair would maintain the inherent properties of the substrate without losing integrity at the repair site. The repaired sites were tested for adhesion, corrosion, hardness, microhardness, surface toughness, thermal stability, ability to withstand bending of the repair site, and the ability to endure a high-pressure water blast without compromising the repaired site. The repaired material could not change the inherent properties of the substrate throughout each of the test in order to remain a possible technique to repair the RSRM substrate materials. One repair method, Electro-Spark Alloying, passed all the testing and is considered a candidate for further evaluation.

  4. Fiberglass dermatitis: report of two cases.

    PubMed

    Wang, B J; Lee, J Y; Wang, R C

    1993-08-01

    Fiberglass is widely used for insulation and as a reinforcement filling material. Handling fiberglass products may induce contact dermatitis. We report on the first two cases of fiberglass dermatitis reported in Taiwan. The first patient suffered from a severe pruritic eruption two hours after repairing a roof with wave-form ceiling boards. Erythematous maculopapules were present on both hands and finger webs. The second patient was a quality controller of printed circuit boards (PRCBs). She presented with erythematous maculopapules on the face and excoriated papules and lichenified plaques on the trunk and forearms, which had been present for two years. Scrapings of the skin lesions from both patients showed fiberglass spicules of 7.5 to 8 microns in diameter. Similar fibers were detected in scrapings from the wave-form ceiling board and PRCB. Histopathology of the second case revealed spongiotic psoriasiform dermatitis. Patch tests in case 2 with the plastics and glues series, epoxy resin and scrapings from the PRCBs were all negative. Fiberglass dermatitis may be easily misdiagnosed. Clinically, it may resemble scabies, eczematous dermatitis, folliculitis, petechiae and urticaria. A high index of suspicion is essential for a correct diagnosis.

  5. Evaluation of high performance pavement and bridge deck wearing surface repair materials.

    DOT National Transportation Integrated Search

    2016-08-01

    This project provided for a laboratory and field testing of several high performance repair materials for : pavements and concrete bridge decks. The main purpose was to provide ODOT with materials and procedures : to shorten road and bridge closures....

  6. Preparation of porous PLA/DBM composite biomaterials and experimental research of repair rabbit radius segmental bone defect.

    PubMed

    Zhang, Yumin; Wang, Jianru; Wang, Jue; Niu, Xiaojun; Liu, Jianchun; Gao, Lan; Zhai, Xiaoyan; Chu, Kaibo

    2015-12-01

    Bone substitutes are used in wide range of orthopaedic application. An ideal bone substitute should exhibit superior osteoinductive and osteoconductive properties. Neither bio-derived materials nor synthetic materials can meet the needs of an ideal bone substitute. Preparation of composite materials is a promising way to improve properties of biomaterial. In this study, the porous poly lactic acid (PLA)/demineralized bone matrix (DBM) composite biomaterials prepared by supercritical CO2 technique were implanted to repair rabbit radius segmental bone defect. By comparing with PLA and bone autograft, the X-ray result and histological analysis showed the repair effect of PLA/DBM porous composite materials is significantly better than that of the PLA group and the blank control group, and is similar to autologous bone. The PLA/DBM can promote the healing of bone defects and can be used as a kind of ideal alternative materials to repair bone defects.

  7. Use of microstrip patch antennas in grain permittivity measurement

    USGS Publications Warehouse

    El Sabbagh, M.A.; Ramahi, O.M.; Trabelsi, S.; Nelson, S.O.; Khan, L.

    2003-01-01

    In this paper, a compact size free-space setup is proposed for the measurement of complex permittivity of granular materials. The horn antennas in the conventional setup are replaced by microstrip patch antennas which is a step toward system miniaturization. The experimental results obtained are in good agreement with those obtained with horn antennas.

  8. 75 FR 40852 - Notice Pursuant to the National Cooperative Research and Production Act of 1993-Development of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-14

    ... DEPARTMENT OF JUSTICE Antitrust Division Notice Pursuant to the National Cooperative Research and Production Act of 1993--Development of High Toughness, Low Viscosity Resin for Reinforcing Pothole Patching...''), Development of High Toughness, Low Viscosity Resin for Reinforcing Pothole Patching Materials, TIP Award No...

  9. Retrospective dosimetry using OSL of tooth enamel and dental repair materials irradiated under wet and dry conditions.

    PubMed

    Geber-Bergstrand, Therése; Bernhardsson, Christian; Mattsson, Sören; Rääf, Christopher L

    2012-11-01

    Following a radiological or nuclear emergency event, there is a need for quick and reliable dose estimations of potentially exposed people. In situations where dosimeters are not readily available, the dose estimations must be carried out using alternative methods. In the present study, the optically stimulated luminescence (OSL) properties of tooth enamel and different dental repair materials have been examined. Specimens of the materials were exposed to gamma and beta radiation in different types of liquid environments to mimic the actual irradiation situation in the mouth. Measurements were taken using a Risø TL/OSL reader, and irradiations were made using a (90)Sr/(90)Y source and a linear accelerator (6 MV photons). Results show that the OSL signal from tooth enamel decreases substantially when the enamel is kept in a wet environment. Thus, tooth enamel is not reliable for retrospective dose assessment without further studies of the phenomenon. Dental repair materials, on the other hand, do not exhibit the same effect when exposed to liquids. In addition, dose-response and fading measurements of the dental repair materials show promising results, making these materials highly interesting for retrospective dosimetry. The minimum detectable dose for the dental repair materials has been estimated to be 20-185 mGy.

  10. Percutaneous fetoscopic closure of large open spina bifida using a bilaminar skin substitute.

    PubMed

    Lapa Pedreira, Denise A; Acacio, Gregório L; Gonçalves, Rodrigo T; Sá, Renato Augusto M; Brandt, Reynaldo A; Chmait, Ramen; Kontopoulos, Eftichia; Quintero, Ruben A

    2018-01-04

    We have previously described our percutaneous fetoscopic technique for the treatment of open spina bifida (OSB). However, approximately 20-30% of OSB defects are too large to allow primary skin closure. We hereby describe a modification of our standard technique using a bilaminar skin substitute to allow closure of such large spinal defects. The aim of this study was to report our clinical experience with the use of a bilaminar skin substitute and a percutaneous fetoscopic technique for the prenatal closure of large spina bifida defects. Surgeries were performed between 24.0 and 28.9 gestational weeks under general anesthesia, using an entirely percutaneous fetoscopic approach with partial CO2 insufflation of the uterine cavity, as previously described. If there was enough skin to be sutured in the midline, only a biocellulose patch was placed over the placode. In cases where skin approximation was not possible, a bilaminar skin substitute (two layers: one silicone and one dermal matrix) was placed over the biocellulose. The surgical site was assessed at birth, and long-term follow-up was performed. Forty-seven consecutive fetuses underwent percutaneous fetoscopic OSB repair. Premature preterm rupture of membranes (PPROM) occurred in 38 (84%), and the mean gestational age at delivery was 32,8 + 2.5 weeks. A bilaminar skin substitute was required in 13 (29%), of which 5 was associated with myeloschisis. In all cases the skin substitute was found at the surgical site, at birth. In 3 (15%) of these cases, postnatal additional repair was needed. In the other 10 cases, the silicone layer detached spontaneously from the dermal matrix (average 25 days after birth), and the lesion healed by secondary-intention. Operating time was significantly longer in cases requiring the bilaminar skin substitute (additional 42 minutes). The subgroup with bilaminar skin substitute had similar PPROM rate and delivery gestational age compared to the one patch group. Complete reversal of hindbrain herniation occurred in 68% of the one patch and in 33% (p < 0.05) of the two patches group. In 4 cases there was no reversal and 3 of them were myeloschisis cases. Large OSB defects may be successfully treated in utero using a bilaminar skin substitute over a biocellulose patch through an entirely percutaneous approach. Although the operating time is longer, surgical outcomes are similar to cases closed primarily. Myeloschisis seems to have a worse prognosis then myelomeningocele cases. PPROM and preterm birth continue to be a challenge. Further experience is needed to assess the risks and benefits of this technique for management of large OSB defects. This article is protected by copyright. All rights reserved.

  11. Adaptable Holders for Arc-Jet Screening Candidate Thermal Protection System Repair Materials

    NASA Technical Reports Server (NTRS)

    Riccio, Joe; Milhoan, Jim D.

    2010-01-01

    Reusable holders have been devised for evaluating high-temperature, plasma-resistant re-entry materials, especially fabrics. Typical material samples tested support thermal-protection-system damage repair requiring evaluation prior to re-entry into terrestrial atmosphere. These tests allow evaluation of each material to withstand the most severe predicted re-entry conditions.

  12. Whole-Cell Electrical Activity Under Direct Mechanical Stimulus by AFM Cantilever Using Planar Patch Clamp Chip Approach

    PubMed Central

    Upadhye, Kalpesh V.; Candiello, Joseph E.; Davidson, Lance A.; Lin, Hai

    2011-01-01

    Patch clamp is a powerful tool for studying the properties of ion-channels and cellular membrane. In recent years, planar patch clamp chips have been fabricated from various materials including glass, quartz, silicon, silicon nitride, polydimethyl-siloxane (PDMS), and silicon dioxide. Planar patch clamps have made automation of patch clamp recordings possible. However, most planar patch clamp chips have limitations when used in combination with other techniques. Furthermore, the fabrication methods used are often expensive and require specialized equipments. An improved design as well as fabrication and characterization of a silicon-based planar patch clamp chip are described in this report. Fabrication involves true batch fabrication processes that can be performed in most common microfabrication facilities using well established MEMS techniques. Our planar patch clamp chips can form giga-ohm seals with the cell plasma membrane with success rate comparable to existing patch clamp techniques. The chip permits whole-cell voltage clamp recordings on variety of cell types including Chinese Hamster Ovary (CHO) cells and pheochromocytoma (PC12) cells, for times longer than most available patch clamp chips. When combined with a custom microfluidics chamber, we demonstrate that it is possible to perfuse the extra-cellular as well as intra-cellular buffers. The chamber design allows integration of planar patch clamp with atomic force microscope (AFM). Using our planar patch clamp chip and microfluidics chamber, we have recorded whole-cell mechanosensitive (MS) currents produced by directly stimulating human keratinocyte (HaCaT) cells using an AFM cantilever. Our results reveal the spatial distribution of MS ion channels and temporal details of the responses from MS channels. The results show that planar patch clamp chips have great potential for multi-parametric high throughput studies of ion channel proteins. PMID:22174731

  13. Advanced engineering and biomimetic materials for bone repair and regeneration

    NASA Astrophysics Data System (ADS)

    Yang, Lei; Zhong, Chao

    2013-12-01

    Over the past decade, there has been tremendous progress in developing advanced biomaterials for tissue repair and regeneration. This article reviews the frontiers of this field from two closely related areas, new engineering materials for bone substitution and biomimetic mineralization for bone-like nanocomposites. Rather than providing an exhaustive overview of the literature, we focus on several representative directions. We also discuss likely future trends in these areas, including synthetic biology-enabled biomaterials design and multifunctional implant materials for bone repair and regeneration.

  14. Double-strand break repair and genetic recombination in topoisomerase and primase mutants of bacteriophage T4.

    PubMed

    Shcherbakov, Victor P; Kudryashova, Elena

    2014-09-01

    The effects of primase and topoisomerase II deficiency on the double-strand break (DSB) repair and genetic recombination in bacteriophage T4 were studied in vivo using focused recombination. Site-specific DSBs were induced by SegC endonuclease in the rIIB gene of one of the parents. The frequency/distance relationship was determined in crosses of the wild-type phage, topoisomerase II mutant amN116 (gene 39), and primase mutant E219 (gene 61). Ordinary two-factor (i×j) and three-factor (i k×j) crosses between point rII mutations were also performed. These data provide information about the frequency and distance distribution of the single-exchange (splice) and double-exchange (patch) events. In two-factor crosses ets1×i, the topoisomerase and primase mutants had similar recombinant frequencies in crosses at ets1-i distances longer than 1000 bp, comprising about 80% of the corresponding wild-type values. They, however, differ remarkably in crosses at shorter distances. In the primase mutant, the recombinant frequencies are similar to those in the wild-type crosses at distances less than 100 bp, being a bit diminished at longer distances. In two-factor crosses ets1×i of the topoisomerase mutant, the recombinant frequencies were reduced ten-fold at the shortest distances. In three-factor crosses a6 ets1×i, where we measure patch-related recombination, the primase mutant was quite proficient across the entire range of distances. The topoisomerase mutant crosses demonstrated virtually complete absence of rII(+) recombinants at distances up to 33 bp, with the frequencies increasing steadily at longer distances. The data were interpreted as follows. The primase mutant is fully recombination-proficient. An obvious difference from the wild-type state is some shortage of EndoVII function leading to prolonged existence of HJs and thus stretched out ds-branch migration. This is also true for the topoisomerase mutant. However, the latter is deficient in the ss-branch migration step of the DSB repair pathway and partially deficient in HJ initiation. In apparent contradiction to their effects on the DSB-induced site-specific recombination, the topoisomerase and primase mutants demonstrated about 3-8-fold increase in the recombinant frequencies in the ordinary crosses, with the recombination running exclusively via patches. This implies that most of the spontaneous recombination events are not initiated by dsDNA ends in these mutants. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Optimizing the effectiveness of a mechanical suture-based anulus fibrosus repair construct in an acute failure laboratory simulation.

    PubMed

    Bartlett, Ashley; Wales, Larry; Houfburg, Rodney; Durfee, William K; Griffith, Steven L; Bentley, Ishmael

    2013-10-01

    In vitro comparative, laboratory experiments. This study developed a laboratory apparatus that measured resistance to failure using pressures similar to intradiscal pressure of a lumbar spinal disk. Various combinations of an anular repair device were compared. Herniated material of the intervertebral disk is removed during a lumbar discectomy; however, the defect in the anulus fibrosus remains and can provide a pathway for future herniation. Repairing the anulus fibrosus could mitigate this reherniation and improve patient outcomes. A pneumatic cylinder was used to increase the pressure of a sealed chamber until artificial nucleus pulposus material was expulsed through either a 3-mm circular (diameter) or a 6-mm slit anular defect created in a surrogate anulus fibrosus. Each unrepaired condition was compared with 3 repaired conditions using a commercially available soft tissue repair system. The repaired conditions included: (1) a single tension band; (2) 2 tension bands in a cruciate pattern; or (3) 2 tension bands in a parallel pattern. Maximum pressure at the point of extrusion of the internal chamber material and failure or nonfailure of the repair was measured. Significant differences were detected (P<0.05) in maximum failure pressures for the nonrepaired (control) versus repaired conditions. With 1 or 2 tension bands repairing the circular defect, the maximum failure pressure increased by approximately 76% and 131%, respectively. In addition, the failure pressure for 2 tension bands in either a cruciate or parallel configuration was not different, and was approximately 32% higher (P<0.05) than a single tension band in the case of the circular defect. Similar results were seen for the slit defect, with the exception that no difference between the repaired conditions (ie, single vs. 2 tension bands) was detected. This laboratory simulation demonstrated that repairing the anulus fibrosus after a discectomy procedure can be beneficial for retaining intradiscal material. The use of 2 tension bands, versus a single tension band, in either a cruciate or parallel configuration may further improve the ability to retain disk material.

  16. Factors predicting sensory and motor recovery after the repair of upper limb peripheral nerve injuries

    PubMed Central

    He, Bo; Zhu, Zhaowei; Zhu, Qingtang; Zhou, Xiang; Zheng, Canbin; Li, Pengliang; Zhu, Shuang; Liu, Xiaolin; Zhu, Jiakai

    2014-01-01

    OBJECTIVE: To investigate the factors associated with sensory and motor recovery after the repair of upper limb peripheral nerve injuries. DATA SOURCES: The online PubMed database was searched for English articles describing outcomes after the repair of median, ulnar, radial, and digital nerve injuries in humans with a publication date between 1 January 1990 and 16 February 2011. STUDY SELECTION: The following types of article were selected: (1) clinical trials describing the repair of median, ulnar, radial, and digital nerve injuries published in English; and (2) studies that reported sufficient patient information, including age, mechanism of injury, nerve injured, injury location, defect length, repair time, repair method, and repair materials. SPSS 13.0 software was used to perform univariate and multivariate logistic regression analyses and to investigate the patient and intervention factors associated with outcomes. MAIN OUTCOME MEASURES: Sensory function was assessed using the Mackinnon-Dellon scale and motor function was assessed using the manual muscle test. Satisfactory motor recovery was defined as grade M4 or M5, and satisfactory sensory recovery was defined as grade S3+ or S4. RESULTS: Seventy-one articles were included in this study. Univariate and multivariate logistic regression analyses showed that repair time, repair materials, and nerve injured were independent predictors of outcome after the repair of nerve injuries (P < 0.05), and that the nerve injured was the main factor affecting the rate of good to excellent recovery. CONCLUSION: Predictors of outcome after the repair of peripheral nerve injuries include age, gender, repair time, repair materials, nerve injured, defect length, and duration of follow-up. PMID:25206870

  17. Human Fanconi Anemia Complementation Group A Protein Stimulates the 5’ Flap Endonuclease Activity of FEN1

    PubMed Central

    Qian, Liangyue; Yuan, Fenghua; Rodriguez-Tello, Paola; Padgaonkar, Suyog; Zhang, Yanbin

    2013-01-01

    In eukaryotic cells, Flap endonuclease 1 (FEN1) is a major structure-specific endonuclease that processes 5’ flapped structures during maturation of lagging strand DNA synthesis, long patch base excision repair, and rescue of stalled replication forks. Here we report that fanconi anemia complementation group A protein (FANCA), a protein that recognizes 5’ flap structures and is involved in DNA repair and maintenance of replication forks, constantly stimulates FEN1-mediated incision of both DNA and RNA flaps. Kinetic analyses indicate that FANCA stimulates FEN1 by increasing the turnover rate of FEN1 and altering its substrate affinity. More importantly, six pathogenic FANCA mutants are significantly less efficient than the wild-type at stimulating FEN1 endonuclease activity, implicating that regulation of FEN1 by FANCA contributes to the maintenance of genomic stability. PMID:24349332

  18. Engineering biosynthetic excitable tissues from unexcitable cells for electrophysiological and cell therapy studies.

    PubMed

    Kirkton, Robert D; Bursac, Nenad

    2011-01-01

    Patch-clamp recordings in single-cell expression systems have been traditionally used to study the function of ion channels. However, this experimental setting does not enable assessment of tissue-level function such as action potential (AP) conduction. Here we introduce a biosynthetic system that permits studies of both channel activity in single cells and electrical conduction in multicellular networks. We convert unexcitable somatic cells into an autonomous source of electrically excitable and conducting cells by stably expressing only three membrane channels. The specific roles that these expressed channels have on AP shape and conduction are revealed by different pharmacological and pacing protocols. Furthermore, we demonstrate that biosynthetic excitable cells and tissues can repair large conduction defects within primary 2- and 3-dimensional cardiac cell cultures. This approach enables novel studies of ion channel function in a reproducible tissue-level setting and may stimulate the development of new cell-based therapies for excitable tissue repair.

  19. An evaluation of Admedus' tissue engineering process-treated (ADAPT) bovine pericardium patch (CardioCel) for the repair of cardiac and vascular defects.

    PubMed

    Strange, Geoff; Brizard, Christian; Karl, Tom R; Neethling, Leon

    2015-03-01

    Tissue engineers have been seeking the 'Holy Grail' solution to calcification and cytotoxicity of implanted tissue for decades. Tissues with all of the desired qualities for surgical repair of congenital heart disease (CHD) are lacking. An anti-calcification tissue engineering process (ADAPT TEP) has been developed and applied to bovine pericardium (BP) tissue (CardioCel, AdmedusRegen Pty Ltd, Perth, WA, Australia) to eliminate cytotoxicity, improve resistance to acute and chronic inflammation, reduce calcification and facilitate controlled tissue remodeling. Clinical data in pediatric patients, and additional pre-market authorized prescriber data demonstrate that CardioCel performs extremely well in the short term and is safe and effective for a range of congenital heart deformations. These data are supported by animal studies which have shown no more than normal physiologic levels of calcification, with good durability, biocompatibility and controlled healing.

  20. Biomaterials in myocardial tissue engineering

    PubMed Central

    Reis, Lewis A.; Chiu, Loraine L. Y.; Feric, Nicole; Fu, Lara; Radisic, Milica

    2016-01-01

    Cardiovascular disease is the leading cause of death in the developed world, and as such there is a pressing need for treatment options. Cardiac tissue engineering emerged from the need to develop alternate sources and methods of replacing tissue damaged by cardiovascular diseases, as the ultimate treatment option for many who suffer from end-stage heart failure is a heart transplant. In this review we focus on biomaterial approaches to augment injured or impaired myocardium with specific emphasis on: the design criteria for these biomaterials; the types of scaffolds—composed of natural or synthetic biomaterials, or decellularized extracellular matrix—that have been used to develop cardiac patches and tissue models; methods to vascularize scaffolds and engineered tissue, and finally injectable biomaterials (hydrogels)designed for endogenous repair, exogenous repair or as bulking agents to maintain ventricular geometry post-infarct. The challenges facing the field and obstacles that must be overcome to develop truly clinically viable cardiac therapies are also discussed. PMID:25066525

  1. Buccal mucosa ureteroplasty for the treatment of complex ureteric injury.

    PubMed

    Sadhu, Sagar; Pandit, Kuntal; Roy, Manas K; Bajoria, Suresh K

    2011-01-01

    Bowel interposition and auto-transplantation of kidney, thought to be a major undertaking, remain the traditional option for the treatment of major and complex ureteric lesions. Buccal mucosa, a well known tissue for urethral reconstruction, can be used safely for the repair of ureter. However, this has been reported poorly in the literature. Here we report a 59- year-old female who had a major ureteric injury by Dormia basket during ureteroscopic extraction of a 2.6 cm impacted stone at pelvi- ureteric junction. On exploration, a long anterior slit was found in the upper ureter measuring approximately 8 cm. It was successfully repaired by free buccal mucosal patch graft over a Double J stent. Thus, a major surgery was avoided. Intra venous urography at 6-month follow up demonstrated a patent ureter. Our experience is encouraging and merits wider application in complex ureteric lesion.

  2. International Space Station (ISS)

    NASA Image and Video Library

    2005-06-09

    The STS-121 patch depicts the Space Shuttle docked with the International Space Station (ISS) in the foreground, overlaying the astronaut symbol with three gold columns and a gold star. The ISS is shown in the configuration that it was during the STS-121 mission. The background shows the nighttime Earth with a dawn breaking over the horizon. STS-121, ISS mission ULF1.1, was the final Shuttle Return to Flight test mission. This utilization and logistics flight delivered a multipurpose logistics module (MPLM) to the ISS with several thousand pounds of new supplies and experiments. In addition, some new orbital replacement units (ORUs) were delivered and stowed externally on the ISS on a special pallet. These ORUs are spares for critical machinery located on the outside of the ISS. During this mission the crew also carried out testing of Shuttle inspection and repair hardware, as well as evaluated operational techniques and concepts for conducting on-orbit inspection and repair.

  3. Joint sealant materials for concrete pavement repairs.

    DOT National Transportation Integrated Search

    1991-01-01

    This report on joint sealant materials for concrete pavement repairs is based on conversations with specialists from several states, the Federal Highway Administration, the Portland Cement Association, and the American Concrete Pavement Association, ...

  4. 21 CFR 870.1350 - Catheter balloon repair kit.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the balloon of a balloon catheter. The kit contains the materials, such as glue and balloons, necessary to...

  5. 21 CFR 870.1350 - Catheter balloon repair kit.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the balloon of a balloon catheter. The kit contains the materials, such as glue and balloons, necessary to...

  6. 21 CFR 870.1350 - Catheter balloon repair kit.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the balloon of a balloon catheter. The kit contains the materials, such as glue and balloons, necessary to...

  7. Laparoscopic Repair for Perforated Peptic Ulcer in Children.

    PubMed

    Reusens, Helena; Dassonville, Martine; Steyaert, Henri

    2017-06-01

    Introduction  A perforated peptic ulcer (PPU) is a rare but major complication of gastroduodenal peptic ulcer disease. Literature is scarce on this subject in the pediatric population and most articles describe a surgical treatment by laparotomy. We aim to review all our cases of pediatric PPU treated over the past 16 years and compare these to literature to deduce potential benefits and disadvantages regarding laparoscopic treatment of PPU in children. Materials and Methods  A retrospective study of all cases of PPU treated at the Lenval Hospital in Nice (France) and the Queen Fabiola University Hospital for Children in Brussels (Belgium) between 1998 and 2015 was performed. Results  A total of five children were treated for PPU (2 females). The average age was 11 years (range, 3-17). All of them were surgically treated with laparoscopic simple suture of the perforation and placement of an omental patch. There were no mortalities, no conversions, and no extra-abdominal complications or wound dehiscences. Mean operating time was 78.6 minutes (range, 70-115 minutes). Mean duration of intravenous treatment was 6 days (range, 4-12 days). One reintervention was performed for abdominal infection. In one patient, an abdominal drain was left in place for 2 days. The mean time before refeeding was 3.4 days (range, 3-4 days) and mean length of stay was 12 days (range, 7-30 days). Conclusion  Laparoscopic repair is safe and feasible for PPU and should be the gold standard for treatment of PPU in children. Georg Thieme Verlag KG Stuttgart · New York.

  8. Development of Laboratory Testing Criteria for Evaluating Cementitious, Rapid-Setting Pavement Repair Materials

    DTIC Science & Technology

    2011-04-01

    thus they should only be used when experienced operators have been trained on using the material with the mixer. ABC Cement was suited for various... autogenous shrinkage, all of which occur during hydration. Shrinkage potential is important because repair materials that shrink excessively are more

  9. Making on-orbit structural repairs to Space Station

    NASA Technical Reports Server (NTRS)

    Haber, Harry S.; Quinn, Alberta

    1989-01-01

    One of the key factors dictating the safety and durability of the proposed U.S. Space Station is the ability to repair structural damage while remaining in orbit. Consequently, studies are conducted to identify the engineering problems associated with accomplishing structural repairs on orbit, due to zero gravity environment and exposure to extreme temperature variations. There are predominant forms of structural failure, depending on the metallic or composite material involved. Aluminum is the primary metallic material used in space vehicle applications. Welding processes on aluminum alloy structures were tested, resulting in final selection of electron beam welding as the primary technique for metallic material repair in Space. Several composite structure repair processes were bench-tested to define their applicability to on-orbit EVA requirements: induction heating prevailed. One of the unique problems identified as inherent in the on-orbit repair process is that of debris containment. The Maintenance Work Station concept provides means to prevent module contamination from repair debris and ensure the creation of a facility for crew members to work easily in a microgravity environment. Different technologies were also examined for application to EVA repair activities, and the concept selected was a spring-loaded, collapsible, box-like Debris Containement and Collection Device with incorporated fold-down tool boards and handholes in the front panel.

  10. Cryogenic Treatment of Al-Li Alloys for Improved Weldability, Repairability, and Reduction of Residual Stresses

    NASA Technical Reports Server (NTRS)

    Malone, Tina W.; Graham, Benny F.; Gentz, Steven J. (Technical Monitor)

    2001-01-01

    Service performance has shown that cryogenic treatment of some metals provides improved strength, fatigue life, and wear resistance to the processed material. Effects such as these were initially discovered by NASA engineers while evaluating spacecraft that had returned from the cold vacuum of space. Factors such as high cost, poor repairability, and poor machinability are currently prohibitive for wide range use of some aerospace aluminum alloys. Application of a cryogenic treatment process to these alloys is expected provide improvements in weldability and weld properties coupled with a reduction in repairs resulting in a significant reduction in the cost to manufacture and life cycle cost of aerospace hardware. The primary purpose of this effort was to evaluate the effects of deep cryogenic treatment of some aluminum alloy plate products, welds, and weld repairs, and optimize a process for the treatment of these materials. The optimized process is being evaluated for improvements in properties of plate and welds, improvements in weldability and repairability of treated materials, and as an alternative technique for the reduction of residual stresses in repaired welds. This paper will present the results of testing and evaluation conducted in this effort. These results will include assessments of changes in strength, toughness, stress corrosion susceptability, weldability, repairability, and reduction in residual stresses of repaired welds.

  11. Electron-beam Induced Processes and their Applicability to Mask Repair

    NASA Astrophysics Data System (ADS)

    Boegli, Volker A.; Koops, Hans W. P.; Budach, Michael; Edinger, Klaus; Hoinkis, Ottmar; Weyrauch, Bernd; Becker, Rainer; Schmidt, Rudolf; Kaya, Alexander; Reinhardt, Andreas; Braeuer, Stephan; Honold, Heinz; Bihr, Johannes; Greiser, Jens; Eisenmann, Michael

    2002-12-01

    The applicability of electron-beam induced chemical reactions to mask repair is investigated. To achieve deposition and chemical etching with a focused electron-beam system, it is required to disperse chemicals in a molecular beam to the area of interest with a well-defined amount of molecules and monolayers per second. For repair of opaque defects the precursor gas reacts with the absorber material of the mask and forms a volatile reaction product, which leaves the surface. In this way the surface atoms are removed layer by layer. For clear defect repair, additional material, which is light absorbing in the UV, is deposited onto the defect area. This material is rendered as a nanocrystalline deposit from metal containing precursors. An experimental electron-beam mask repair system is developed and used to perform exploratory work applicable to photo mask, EUV mask, EPL and LEEPL stencil mask repair. The tool is described and specific repair actions are demonstrated. Platinum deposited features with lateral dimensions down to 20 nm demonstrate the high resolution obtainable with electron beam induced processes, while AFM and AIMS measurements indicate, that specifications for mask repair at the 70 nm device node can be met. In addition, examples of etching quartz and TaN are given.

  12. 14 CFR 145.101 - General.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) SCHOOLS AND OTHER CERTIFICATED AGENCIES REPAIR STATIONS Housing, Facilities, Equipment, Materials, and Data § 145.101 General. A certificated repair station must provide housing, facilities, equipment, materials, and...

  13. 14 CFR 145.101 - General.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) SCHOOLS AND OTHER CERTIFICATED AGENCIES REPAIR STATIONS Housing, Facilities, Equipment, Materials, and Data § 145.101 General. A certificated repair station must provide housing, facilities, equipment, materials, and...

  14. 14 CFR 145.101 - General.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) SCHOOLS AND OTHER CERTIFICATED AGENCIES REPAIR STATIONS Housing, Facilities, Equipment, Materials, and Data § 145.101 General. A certificated repair station must provide housing, facilities, equipment, materials, and...

  15. 14 CFR 145.101 - General.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) SCHOOLS AND OTHER CERTIFICATED AGENCIES REPAIR STATIONS Housing, Facilities, Equipment, Materials, and Data § 145.101 General. A certificated repair station must provide housing, facilities, equipment, materials, and...

  16. 14 CFR 145.101 - General.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) SCHOOLS AND OTHER CERTIFICATED AGENCIES REPAIR STATIONS Housing, Facilities, Equipment, Materials, and Data § 145.101 General. A certificated repair station must provide housing, facilities, equipment, materials, and...

  17. Anal Sphincter Augmentation Using Biological Material.

    PubMed

    Alam, Nasra N; Narang, Sunil K; Köckerling, Ferdinand; Daniels, Ian R; Smart, Neil J

    2015-01-01

    The aim of this review is to provide an overview of the use of biological materials in the augmentation of the anal sphincter either as part of an overlapping sphincter repair (OSR) or anal bulking procedure. A systematic search of PubMed was conducted using the search terms "anal bulking agents," "anal sphincter repair," or "overlapping sphincter repair." Five studies using biological material as part of an overlapping sphincter repair (OSR) or as an anal bulking agent were identified. 122 patients underwent anal bulking with a biological material. Anorectal physiology was conducted in 27 patients and demonstrated deterioration in maximum resting pressure, and no significant change in maximum squeeze increment. Quality of life scores (QoLs) demonstrated improvements at 6 weeks and 6 months, but this had deteriorated at 12 months of follow up. Biological material was used in 23 patients to carry out an anal encirclement procedure. Improvements in QoLs were observed in patients undergoing OSR as well as anal encirclement using biological material. Incontinence episodes decreased to an average of one per week from 8 to 10 preoperatively. Sphincter encirclement with biological material has demonstrated improvements in continence and QoLs in the short term compared to traditional repair alone. Long-term studies are necessary to determine if this effect is sustained. As an anal bulking agent the benefits are short-term.

  18. Planar patch clamp for neuronal networks--considerations and future perspectives.

    PubMed

    Bosca, Alessandro; Martina, Marzia; Py, Christophe

    2014-01-01

    The patch-clamp technique is generally accepted as the gold standard for studying ion channel activity allowing investigators to either "clamp" membrane voltage and directly measure transmembrane currents through ion channels, or to passively monitor spontaneously occurring intracellular voltage oscillations. However, this resulting high information content comes at a price. The technique is labor-intensive and requires highly trained personnel and expensive equipment. This seriously limits its application as an interrogation tool for drug development. Patch-clamp chips have been developed in the last decade to overcome the tedious manipulations associated with the use of glass pipettes in conventional patch-clamp experiments. In this chapter, we describe some of the main materials and fabrication protocols that have been developed to date for the production of patch-clamp chips. We also present the concept of a patch-clamp chip array providing high resolution patch-clamp recordings from individual cells at multiple sites in a network of communicating neurons. On this chip, the neurons are aligned with the aperture-probes using chemical patterning. In the discussion we review the potential use of this technology for pharmaceutical assays, neuronal physiology and synaptic plasticity studies.

  19. Safety and efficacy of personal care products containing colloidal oatmeal.

    PubMed

    Criquet, Maryline; Roure, Romain; Dayan, Liliane; Nollent, Virginie; Bertin, Christiane

    2012-01-01

    Colloidal oatmeal is a natural ingredient used in the formulation of a range of personal care products for relief of skin dryness and itchiness. It is also used as an adjunctive product in atopic dermatitis. The safety of personal care products used on vulnerable skin is of particular importance and the risk of developing further skin irritations and/or allergies should be minimized. In a series of studies, we tested the safety of personal care products containing oatmeal (creams, cleansers, lotions) by assessing their irritant/allergenic potential on repeat insult patch testing, in safety-in-use and ocular studies using subjects with nonsensitive and sensitive skin. We also tested the skin moisturizing and repair properties of an oatmeal-containing skin care product for dry skin. We found that oatmeal-containing personal care products had very low irritant potential as well as a very low allergenic sensitization potential. Low-level reactions were documented in 1.0% of subjects during the induction phase of repeat insult patch testing; one of 2291 subjects developed a persistent but doubtful low-level reaction involving edema during the challenge phase in repeat insult patch testing. No allergies were reported by 80 subjects after patch testing after in-use application. Sustained skin moisturizing was documented in subjects with dry skin that lasted up to 2 weeks after product discontinuation. Our results demonstrate that colloidal oatmeal is a safe and effective ingredient in personal care products. No allergies were reported by consumers of 445,820 products sold during a 3-year period.

  20. Safety and efficacy of personal care products containing colloidal oatmeal

    PubMed Central

    Criquet, Maryline; Roure, Romain; Dayan, Liliane; Nollent, Virginie; Bertin, Christiane

    2012-01-01

    Background Colloidal oatmeal is a natural ingredient used in the formulation of a range of personal care products for relief of skin dryness and itchiness. It is also used as an adjunctive product in atopic dermatitis. The safety of personal care products used on vulnerable skin is of particular importance and the risk of developing further skin irritations and/or allergies should be minimized. Methods In a series of studies, we tested the safety of personal care products containing oatmeal (creams, cleansers, lotions) by assessing their irritant/allergenic potential on repeat insult patch testing, in safety-in-use and ocular studies using subjects with nonsensitive and sensitive skin. We also tested the skin moisturizing and repair properties of an oatmeal-containing skin care product for dry skin. Results We found that oatmeal-containing personal care products had very low irritant potential as well as a very low allergenic sensitization potential. Low-level reactions were documented in 1.0% of subjects during the induction phase of repeat insult patch testing; one of 2291 subjects developed a persistent but doubtful low-level reaction involving edema during the challenge phase in repeat insult patch testing. No allergies were reported by 80 subjects after patch testing after in-use application. Sustained skin moisturizing was documented in subjects with dry skin that lasted up to 2 weeks after product discontinuation. Conclusion Our results demonstrate that colloidal oatmeal is a safe and effective ingredient in personal care products. No allergies were reported by consumers of 445,820 products sold during a 3-year period. PMID:23204849

  1. Arc Jet Screening Tests Of Phase 1 Orbiter Tile Repair Materials and Uncoated RSI High Temperature Emittance Measurements

    NASA Technical Reports Server (NTRS)

    DelPapa, Steven V.

    2005-01-01

    Arc jet tests of candidate tile repair materials and baseline Orbiter uncoated reusable surface insulation (RSI) were performed in the Johnson Space Center's (JSC) Atmospheric Reentry Materials and Structures Evaluation Facility (ARMSEF) from June 23, 2003, through August 19, 2003. These tests were performed to screen candidate tile repair materials by verifying the high temperature performance and determining the thermal stability. In addition, tests to determine the surface emissivity at high temperatures and the geometric shrinkage of bare RSI were performed. In addition, tests were performed to determine the surface emissivity at high temperatures and the geometric shrinkage of uncoated RSI.

  2. Nickel-titanium wire in circumferential suture of a flexor tendon repair: a comparison to polypropylene.

    PubMed

    Karjalainen, T; He, M; Chong, A K S; Lim, A Y T; Ryhanen, J

    2010-07-01

    Nickel-titanium (NiTi) has been proposed as an alternative material for flexor tendon core suture. To our knowledge, its suitability as a circumferential suture of flexor tendon repair has not been investigated before. The purpose of this ex vivo study was to investigate the biomechanical properties of NiTi circumferential repairs and to compare them with commonly used polypropylene. Forty porcine flexor tendons were cut and repaired by simple running or interlocking mattress technique using 100 microm NiTi wire or 6-0 polypropylene. The NiTi circumferential repairs showed superior stiffness, gap resistance, and load to failure when compared to polypropylene repairs with both techniques. Nickel-titanium wire seems to be a potential material for circumferential repair of flexor tendons. Copyright 2010 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  3. The Strength of Transosseous Medial Meniscal Root Repair Using a Simple Suture Technique Is Dependent on Suture Material and Position.

    PubMed

    Robinson, James R; Frank, Evelyn G; Hunter, Alan J; Jermin, Paul J; Gill, Harinderjit S

    2018-03-01

    A simple suture technique in transosseous meniscal root repair can provide equivalent resistance to cyclic load and is less technically demanding to perform compared with more complex suture configurations, yet maximum yield loads are lower. Various suture materials have been investigated for repair, but it is currently not clear which material is optimal in terms of repair strength. Meniscal root anatomy is also complex; consisting of the ligamentous mid-substance (root ligament), the transition zone between the meniscal body and root ligament; the relationship between suture location and maximum failure load has not been investigated in a simulated surgical repair. (A) Using a knottable, 2-mm-wide, ultra-high-molecular-weight polyethylene (UHMWPE) braided tape for transosseous meniscal root repair with a simple suture technique will give rise to a higher maximum failure load than a repair made using No. 2 UHMWPE standard suture material for simple suture repair. (B) Suture position is an important factor in determining the maximum failure load. Controlled laboratory study. In part A, the posterior root attachment of the medial meniscus was divided in 19 porcine knees. The tibias were potted, and repair of the medial meniscus posterior root was performed. A suture-passing device was used to place 2 simple sutures into the posterior root of the medial meniscus during a repair procedure that closely replicated single-tunnel, transosseous surgical repair commonly used in clinical practice. Ten tibias were randomized to repair with No. 2 suture (Suture group) and 9 tibias to repair with 2-mm-wide knottable braided tape (Tape group). The repair strength was assessed by maximum failure load measured by use of a materials testing machine. Micro-computed tomography (CT) scans were obtained to assess suture positions within the meniscus. The wide range of maximum failure load appeared related to suture position. In part B, 10 additional porcine knees were prepared. Five knees were randomized to the Suture group and 5 to the Tape group. All repairs were standardized for location, and the repair was placed in the body of the meniscus. A custom image registration routine was created to coregister all 29 menisci, which allowed the distribution of maximum failure load versus repair location to be visualized with a heat map. In part A, higher maximum failure load was found for the Tape group (mean, 86.7 N; 95% CI, 63.9-109.6 N) compared with the Suture group (mean, 57.2 N; 95% CI, 30.5-83.9 N). The 3D micro-CT analysis of suture position showed that the mean maximum failure load for repairs placed in the meniscus body (mean, 104 N; 95% CI, 81.2-128.0 N) was higher than for those placed in the root ligament (mean, 35.1 N; 95% CI, 15.7-54.5 N). In part B, the mean maximum failure load was significantly greater for the Tape group, 298.5 N ( P = .016, Mann-Whitney U; 95% CI, 183.9-413.1 N), compared with that for the Suture group, 146.8 N (95% CI, 82.4-211.6 N). Visualization with the heat map revealed that small variations in repair location on the meniscus were associated with large differences in maximum failure load; moving the repair entry point by 3 mm could reduce the failure load by 50%. The use of 2-mm braided tape provided higher maximum failure load than the use of a No. 2 suture. The position of the repair in the meniscus was also a highly significant factor in the properties of the constructs. The results provide insight into material and location for optimal repair strength.

  4. Management of war-related vascular injuries: experience from the second gulf war.

    PubMed

    Jawas, Ali; Abbas, Alaa K; Nazzal, Munier; Albader, Marzoog; Abu-Zidan, Fikri M

    2013-07-01

    To study the biomechanism, pattern of injury, management, and outcome of major vascular injuries treated at Mubarak Al-Kabeer Teaching Hospital, Kuwait during the Second Gulf War. This is a descriptive retrospective study. War-related injured patients who had major vascular injuries and were treated at Mubarak Al-Kabeer Teaching Hospital from August 1990 to September 1991 were studied. Studied variables included age, gender, anatomical site of vascular injury, mechanism of injury, associated injuries, type of vascular repair, and clinical outcome. 36 patients having a mean (SD) age of 29.8 (10.2) years were studied. 32 (89%) were males and 21 (58%) were civilians. Majority of injuries were caused by bullets (47.2%) and blast injuries (47.2%). Eight patients (22%) presented with shock.There were 31 arterial injuries, common and superficial femoral artery injuries were most common (10/31). Arterial repair included interposition saphenous vein graft in seven patients, thrombectomy with end-to-end / lateral repair in twelve patients, vein patch in two patients, and arterial ligation in four patients. Six patients had arterial ligation as part of primary amputation. 3/21 (14.3%) patients had secondary amputation after attempted arterial vascular repair of an extremity. There were a total of 17 venous injuries, 13 managed by lateral suture repair and 4 by ligation. The median (range) hospital stay was 8 (1-76) days. 5 patients died (14%). Major vascular injuries occurred in 10% of hospitalized war-related injured patients. Our secondary amputation rate of extremities was 14%. The presence of a vascular surgeon within a military surgical team is highly recommended. Basic principles and techniques of vascular repair remain an essential part of training general surgeons because it may be needed in unexpected wars.

  5. Aortic valve repair using a differentiated surgical strategy.

    PubMed

    Langer, Frank; Aicher, Diana; Kissinger, Anke; Wendler, Olaf; Lausberg, Henning; Fries, Roland; Schäfers, Hans-Joachim

    2004-09-14

    Reconstruction of the aortic valve for aortic regurgitation (AR) remains challenging, in part because of not only cusp or root pathology but also a combination of both can be responsible for this valve dysfunction. We have systematically tailored the repair to the individual pathology of cusps and root. Between October 1995 and August 2003, aortic valve repair was performed in 282 of 493 patients undergoing surgery for AR and concomitant disease. Root dilatation was corrected by subcommissural plication (n=59), supracommissural aortic replacement (n=27), root remodeling (n=175), or valve reimplantation within a graft (n=24). Cusp prolapse was corrected by plication of the free margin (n=157) or triangular resection (n =36), cusp defects were closed with a pericardial patch (n=16). Additional procedures were arch replacement (n=114), coronary artery bypass graft (n=60) or mitral repair (n=24). All patients were followed-up (follow-up 99.6% complete), and cumulative follow-up was 8425 patient-months (mean, 33+/-27 months).Results- Eleven patients died in hospital (3.9%). Nine patients underwent reoperation for recurrent AR (3.3%). Actuarial freedom from AR grade > or =II at 5 years was 81% for isolated valve repair, 84% for isolated root replacement, and 94% for combination of both; actuarial freedom from reoperation at 5 years was 93%, 95%, and 98%, respectively. No thromboembolic events occurred, and there was 1 episode of endocarditis 4.5 years postoperatively. Aortic valve repair is feasible even for complex mechanisms of AR with a systematic and individually tailored approach. Operative mortality is low and mid-term durability is encouraging. The incidence of valve-related morbidity is low compared with valve replacement.

  6. Piezoelectric materials as stimulatory biomedical materials and scaffolds for bone repair.

    PubMed

    Tandon, Biranche; Blaker, Jonny J; Cartmell, Sarah H

    2018-04-16

    The process of bone repair and regeneration requires multiple physiological cues including biochemical, electrical and mechanical - that act together to ensure functional recovery. Myriad materials have been explored as bioactive scaffolds to deliver these cues locally to the damage site, amongst these piezoelectric materials have demonstrated significant potential for tissue engineering and regeneration, especially for bone repair. Piezoelectric materials have been widely explored for power generation and harvesting, structural health monitoring, and use in biomedical devices. They have the ability to deform with physiological movements and consequently deliver electrical stimulation to cells or damaged tissue without the need of an external power source. Bone itself is piezoelectric and the charges/potentials it generates in response to mechanical activity are capable of enhancing bone growth. Piezoelectric materials are capable of stimulating the physiological electrical microenvironment, and can play a vital role to stimulate regeneration and repair. This review gives an overview of the association of piezoelectric effect with bone repair, and focuses on state-of-the-art piezoelectric materials (polymers, ceramics and their composites), the fabrication routes to produce piezoelectric scaffolds, and their application in bone repair. Important characteristics of these materials from the perspective of bone tissue engineering are highlighted. Promising upcoming strategies and new piezoelectric materials for this application are presented. Electrical stimulation/electrical microenvironment are known effect the process of bone regeneration by altering the cellular response and are crucial in maintaining tissue functionality. Piezoelectric materials, owing to their capability of generating charges/potentials in response to mechanical deformations, have displayed great potential for fabricating smart stimulatory scaffolds for bone tissue engineering. The growing interest of the scientific community and compelling results of the published research articles has been the motivation of this review article. This article summarizes the significant progress in the field with a focus on the fabrication aspects of piezoelectric materials. The review of both material and cellular aspects on this topic ensures that this paper appeals to both material scientists and tissue engineers. Copyright © 2018. Published by Elsevier Ltd.

  7. Method for repair of thin glass coatings. [on space shuttle orbiter tiles

    NASA Technical Reports Server (NTRS)

    Holt, J. W.; Helman, D. D.; Smiser, L. W.

    1982-01-01

    A method of repairing cracks or damaged areas in glass, in particular, glass coatings provided on tile. The method includes removing the damaged area using a high speed diamond burr drilling out a cavity that extends slightly into the base material of the tile. All loose material is then cleaned from the drilled out cavity and the cavity is filled adjacent the upper surface of the coating with a filler material including chopped silica fibers mixed with a binder. The filler material is packed into the cavity and a repair coating is applied by means of a brush or sprayed thereover. The repair includes borosilicate suspended in solution. Heat is applied at approximately 2100 F. for approximately five minutes for curing the coating, causing boron silicide particles of the coating to oxidize forming a very fluid boron-oxide rich glass which reacts with the other frits to form an impervious, highly refractory layer.

  8. Biomaterial applications in cardiovascular tissue repair and regeneration

    PubMed Central

    Lam, Mai T; Wu, Joseph C

    2013-01-01

    Cardiovascular disease physically damages the heart, resulting in loss of cardiac function. Medications can help alleviate symptoms, but it is more beneficial to treat the root cause by repairing injured tissues, which gives patients better outcomes. Besides heart transplants, cardiac surgeons use a variety of methods for repairing different areas of the heart such as the ventricular septal wall and valves. A multitude of biomaterials are used in the repair and replacement of impaired heart tissues. These biomaterials fall into two main categories: synthetic and natural. Synthetic materials used in cardiovascular applications include polymers and metals. Natural materials are derived from biological sources such as human donor or harvested animal tissues. A new class of composite materials has emerged to take advantage of the benefits of the strengths and minimize the weaknesses of both synthetic and natural materials. This article reviews the current and prospective applications of biomaterials in cardiovascular therapies. PMID:23030293

  9. Self-repair of cracks in brittle material systems

    NASA Astrophysics Data System (ADS)

    Dry, Carolyn M.

    2016-04-01

    One of the most effective uses for self repair is in material systems that crack because the cracks can allow the repair chemical to flow into the crack damage sites in all three dimensions. In order for the repair chemical to stay in the damage site and flow along to all the crack and repair there must be enough chemical to fill the entire crack. The repair chemical must be designed appropriately for the particular crack size and total volume of cracks. In each of the three examples of self repair in crackable brittle systems, the viscosity and chemical makeup and volume of the repair chemicals used is different for each system. Further the chemical delivery system has to be designed for each application also. Test results from self repair of three brittle systems are discussed. In "Self Repair of Concrete Bridges and Infrastructure" two chemicals were used due to different placements in bridges to repair different types of cracks- surface shrinkage and shear cracks, In "Airplane Wings and Fuselage, in Graphite" the composite has very different properties than the concrete bridges. In the graphite for airplane components the chemical also had to survive the high processing temperatures. In this composite the cracks were so definite and deep and thin that the repair chemical could flow easily and repair in all layers of the composite. In "Ceramic/Composite Demonstrating Self Repair" the self repair system not only repaired the broken ceramic but also rebounded the composite to the ceramic layer

  10. The Human Ligase IIIα-XRCC1 Protein Complex Performs DNA Nick Repair after Transient Unwrapping of Nucleosomal DNA*

    PubMed Central

    Rashid, Ishtiaque; Tomkinson, Alan E.; Pederson, David S.

    2017-01-01

    Reactive oxygen species generate potentially cytotoxic and mutagenic lesions in DNA, both between and within the nucleosomes that package DNA in chromatin. The vast majority of these lesions are subject to base excision repair (BER). Enzymes that catalyze the first three steps in BER can act at many sites in nucleosomes without the aid of chromatin-remodeling agents and without irreversibly disrupting the host nucleosome. Here we show that the same is true for a protein complex comprising DNA ligase IIIα and the scaffolding protein X-ray repair cross-complementing protein 1 (XRCC1), which completes the fourth and final step in (short-patch) BER. Using in vitro assembled nucleosomes containing discretely positioned DNA nicks, our evidence indicates that the ligase IIIα-XRCC1 complex binds to DNA nicks in nucleosomes only when they are exposed by periodic, spontaneous partial unwrapping of DNA from the histone octamer; that the scaffolding protein XRCC1 enhances the ligation; that the ligation occurs within a complex that ligase IIIα-XRCC1 forms with the host nucleosome; and that the ligase IIIα-XRCC1-nucleosome complex decays when ligation is complete, allowing the host nucleosome to return to its native configuration. Taken together, our results illustrate ways in which dynamic properties intrinsic to nucleosomes may contribute to the discovery and efficient repair of base damage in chromatin. PMID:28184006

  11. Critical and subcritical damage monitoring of bonded composite repairs using innovative non-destructive techniques

    NASA Astrophysics Data System (ADS)

    Grammatikos, S. A.; Kordatos, E. Z.; Aggelis, D. G.; Matikas, T. E.; Paipetis, A. S.

    2012-04-01

    Infrared Thermography (IrT) has been shown to be capable of detecting and monitoring service induced damage of repair composite structures. Full-field imaging, along with portability are the primary benefits of the thermographic technique. On-line lock-in thermography has been reported to successfully monitor damage propagation or/and stress concentration in composite coupons, as mechanical stresses in structures induce heat concentration phenomena around flaws. During mechanical fatigue, cyclic loading plays the role of the heating source and this allows for critical and subcritical damage identification and monitoring using thermography. The Electrical Potential Change Technique (EPCT) is a new method for damage identification and monitoring during loading. The measurement of electrical potential changes at specific points of Carbon Fiber Reinforced Polymers (CFRPs) under load are reported to enable the monitoring of strain or/and damage accumulation. Along with the aforementioned techniques Finally, Acoustic Emission (AE) method is well known to provide information about the location and type of damage. Damage accumulation due to cyclic loading imposes differentiation of certain parameters of AE like duration and energy. Within the scope of this study, infrared thermography is employed along with AE and EPCT methods in order to assess the integrity of bonded repair patches on composite substrates and to monitor critical and subcritical damage induced by the mechanical loading. The combined methodologies were effective in identifying damage initiation and propagation of bonded composite repairs.

  12. Patch test reactions to mite antigens: a GERDA multicentre study. Groupe d'Etudes et de Recherches en Dermato-Allergie.

    PubMed

    Castelain, M; Birnbaum, J; Castelain, P Y; Ducombs, G; Grosshans, E; Jelen, G; Lacroix, M; Meynadier, J; Mougeolle, J M; Lachapelle, J M

    1993-11-01

    We performed patch tests with Dermatophagoides pteronyssinus (Dp) antigens from 2 different sources in 355 non-randomly selected patients with atopic dermatitis (AD) and 398 subjects of a control group. The study demonstrated that contact sensitization to mites occurred in an appreciable % of AD cases (20.8%), using commonly available assay products. The differences recorded between the 2 materials tested were related to the concentration of P1 antigen. Non-atopic patients rarely showed positive reactions to Dp (0.75%), when strict criteria for readings were applied and if 2 readings were performed. Patients with positive patch tests did not necessarily show positive immediate skin tests. It would be useful to carry out tests systematically in atopic patients, even if it is not yet known what modern treatment would be best for the patient. Laboratories still do not provide standardized house dust mite preparations--measuring and codifying their biological activity--for use in patch tests. It is to be hoped that the extension of this type of test will lead to the production of better test materials, in syringes with homogeneous dispersion and concentration.

  13. Circularly Polarized S Band Dual Frequency Square Patch Antenna Using Glass Microfiber Reinforced PTFE Composite

    PubMed Central

    Samsuzzaman, M.; Islam, M. T.; Arshad, Haslina; Mandeep, J. S.; Misran, N.

    2014-01-01

    Circularly polarized (CP) dual frequency cross-shaped slotted patch antenna on 1.575 mm thick glass microfiber reinforced polytetrafluoroethylene (PTFE) composite material substrate is designed and fabricated for satellite applications. Asymmetric cross-shaped slots are embedded in the middle of the square patch for CP radiation and four hexagonal slots are etched on the four sides of the square patch for desired dual frequency. Different substrate materials have been analysed to achieve the desired operating band. The experimental results show that the impedance bandwidth is approximately 30 MHz (2.16 GHz to 2.19 GHz) for lower band and 40 MHz (3.29 GHz to 3.33 GHz) for higher band with an average peak gain of 6.59 dBiC and 5.52 dBiC, respectively. Several optimizations are performed to obtain the values of the antenna physical parameters. Moreover, the proposed antenna possesses compactness, light weight, simplicity, low cost, and circularly polarized. It is an attractive candidate for dual band satellite antennas where lower band can be used for uplink and upper band can be used for downlink. PMID:24982943

  14. Study of the Effect of Ellipsoidal Shape on the Kern and Frenkel Patch Model

    NASA Astrophysics Data System (ADS)

    Nguyen, Thienbao; Gunton, James; Rickman, Jeffrey

    In their work on the self-assembly of complex structures, Glotzer and Solomon (Nature Materials 6, 557 - 562 (2007)) identified both interaction and shape anisotropy as two of several means to build complex structures. Advances in fabricating materials and new insights into protein biology have revealed the importance of these types of interactions. The Kern and Frenkel (J. Chem. Phys. 118, 9882 (2003) model of hard spheres carrying interaction patches of various sizes has been used extensively to describe interaction anisotropies important in protein phase transitions. However their model did not also account for shape anisotropy. We studied the role of both shape and interaction anisotropy by applying N=2 and N=4 attractive Kern and Frenkel patches with an interaction range to hard ellipsoids with various aspect ratios and patch coverages. Following Kern and Frenkel, we studied the liquid-liquid phase separation of our particles using a Monte Carlo simulation. We found the critical temperatures for our model using the approximate law of rectilinear diameter and compared them with the original results of Kern and Frenkel. We found that the critical temperatures increased both with aspect ratio and percent coverage. G Harold and Leila Y Mathers Foundation.

  15. 30 CFR 56.6801 - Vehicle repair.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Vehicle repair. 56.6801 Section 56.6801 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND... Vehicle repair. Vehicles containing explosive material and oxidizers shall not be taken into a repair...

  16. 30 CFR 56.6801 - Vehicle repair.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Vehicle repair. 56.6801 Section 56.6801 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND... Vehicle repair. Vehicles containing explosive material and oxidizers shall not be taken into a repair...

  17. 30 CFR 56.6801 - Vehicle repair.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Vehicle repair. 56.6801 Section 56.6801 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND... Vehicle repair. Vehicles containing explosive material and oxidizers shall not be taken into a repair...

  18. 30 CFR 56.6801 - Vehicle repair.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Vehicle repair. 56.6801 Section 56.6801 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND... Vehicle repair. Vehicles containing explosive material and oxidizers shall not be taken into a repair...

  19. 30 CFR 56.6801 - Vehicle repair.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Vehicle repair. 56.6801 Section 56.6801 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND... Vehicle repair. Vehicles containing explosive material and oxidizers shall not be taken into a repair...

  20. XRCC1 suppresses somatic hypermutation and promotes alternative nonhomologous end joining in Igh genes.

    PubMed

    Saribasak, Huseyin; Maul, Robert W; Cao, Zheng; McClure, Rhonda L; Yang, William; McNeill, Daniel R; Wilson, David M; Gearhart, Patricia J

    2011-10-24

    Activation-induced deaminase (AID) deaminates cytosine to uracil in immunoglobulin genes. Uracils in DNA can be recognized by uracil DNA glycosylase and abasic endonuclease to produce single-strand breaks. The breaks are repaired either faithfully by DNA base excision repair (BER) or mutagenically to produce somatic hypermutation (SHM) and class switch recombination (CSR). To unravel the interplay between repair and mutagenesis, we decreased the level of x-ray cross-complementing 1 (XRCC1), a scaffold protein involved in BER. Mice heterozygous for XRCC1 showed a significant increase in the frequencies of SHM in Igh variable regions in Peyer's patch cells, and of double-strand breaks in the switch regions during CSR. Although the frequency of CSR was normal in Xrcc1(+/-) splenic B cells, the length of microhomology at the switch junctions decreased, suggesting that XRCC1 also participates in alternative nonhomologous end joining. Furthermore, Xrcc1(+/-) B cells had reduced Igh/c-myc translocations during CSR, supporting a role for XRCC1 in microhomology-mediated joining. Our results imply that AID-induced single-strand breaks in Igh variable and switch regions become substrates simultaneously for BER and mutagenesis pathways.

  1. The nucleosome: orchestrating DNA damage signaling and repair within chromatin.

    PubMed

    Agarwal, Poonam; Miller, Kyle M

    2016-10-01

    DNA damage occurs within the chromatin environment, which ultimately participates in regulating DNA damage response (DDR) pathways and repair of the lesion. DNA damage activates a cascade of signaling events that extensively modulates chromatin structure and organization to coordinate DDR factor recruitment to the break and repair, whilst also promoting the maintenance of normal chromatin functions within the damaged region. For example, DDR pathways must avoid conflicts between other DNA-based processes that function within the context of chromatin, including transcription and replication. The molecular mechanisms governing the recognition, target specificity, and recruitment of DDR factors and enzymes to the fundamental repeating unit of chromatin, i.e., the nucleosome, are poorly understood. Here we present our current view of how chromatin recognition by DDR factors is achieved at the level of the nucleosome. Emerging evidence suggests that the nucleosome surface, including the nucleosome acidic patch, promotes the binding and activity of several DNA damage factors on chromatin. Thus, in addition to interactions with damaged DNA and histone modifications, nucleosome recognition by DDR factors plays a key role in orchestrating the requisite chromatin response to maintain both genome and epigenome integrity.

  2. Genetics of human sensitivity to ultraviolet radiation

    NASA Astrophysics Data System (ADS)

    Cleaver, James E.

    1994-07-01

    the major human health effects of solar and artificial UV light occur from the UVB and UVC wavelength ranges and involve a variety of short-term and long-term deleterious changes to the skin and eyes. the more important initial damage to cellular macromolecules involves dimerization of adjacent pyrimidines in DNA to produce cyclobutane pyrimidine dimes, (6-4) pyrimidine- pyrimidone, and (6-4) dewar photoproducts. these photoproducts can be repaired by a genetically regulated enzyme system (nucleotide excision repair) which removes oligonucleotides 29-30 nucleotides long that contain the photoproducts, and synthesizes replacement patches. At least a dozen gene products are involved in the process of recognizing photoproducts in DNA, altering local DNA helicity and cleaving the polynucleotide chain at defined positions either side of a photoproduct. Hereditary mutations in many of these genes are recognized in the human genetic disorders xeroderma pigmentosum (XP), Cockayne syndrome (CS), and trichothiodystrophy (TTD). Several of the gene products have other functions involving the regulation of gene transcription which accounts for the complex clinical presentation of repair deficient diseases that involve sensitivity of the skin and eyes to UV light, increased solar carcinogenesis (in XP), demyelination, and ganglial calcification (in CS), hair abnormalities (in TTD), and developmental and neurological abnormalities

  3. MSE wall void repair effect on corrosion of reinforcement - phase 2 : specialty fill materials.

    DOT National Transportation Integrated Search

    2015-08-01

    This project provided information and recommendations for material selection for best : corrosion control of reinforcement in mechanically stabilized earth (MSE) walls with void repairs. The : investigation consisted of small- and large-scale experim...

  4. LTPP pavement maintenance materials : PCC partial-depth spall repair experiment, final report.

    DOT National Transportation Integrated Search

    1999-10-01

    The Strategic Highway Research Program (SHRP) H-106 maintenance experiment and the Federal Highway Administration : (FHWA) Long-Term Monitoring (LTM) of Pavement Maintenance Materials Test Sites project studied the repair of partialdepth : spalls in ...

  5. Biomechanical characteristics of single-row repair in comparison to double-row repair with consideration of the suture configuration and suture material.

    PubMed

    Baums, M H; Buchhorn, G H; Spahn, G; Poppendieck, B; Schultz, W; Klinger, H-M

    2008-11-01

    The aim of the study was to evaluate the time zero mechanical properties of single- versus double-row configuration for rotator cuff repair in an animal model with consideration of the stitch technique and suture material. Thirty-two fresh-frozen sheep shoulders were randomly assigned to four repair groups: suture anchor single-row repair coupled with (1) braided, nonabsorbable polyester suture sized USP No. 2 (SRAE) or (2) braided polyblend polyethylene suture sized No. 2 (SRAH). The double-row repair was coupled with (3) USP No. 2 (DRAE) or (4) braided polyblend polyethylene suture No. 2 (DRAH). Arthroscopic Mason-Allen stitches were used (single-row) and combined with medial horizontal mattress stitches (double-row). Shoulders were cyclically loaded from 10 to 180 N. Displacement to gap formation of 5- and 10-mm at the repair site, cycles to failure, and the mode of failure were determined. The ultimate tensile strength was verified in specimens that resisted to 3,000 cycles. DRAE and DRAH had a lower frequency of 5- (P = 0.135) and 10-mm gap formation (P = 0.135). All DRAE and DRAH resisted 3,000 cycles while only three SRAE and one SRAH resisted 3,000 cycles (P < 0.001). The ultimate tensile strength in double-row specimens was significantly higher than in others (P < 0.001). There was no significant variation in using different suture material (P > 0.05). Double-row suture anchor repair with arthroscopic Mason-Allen/medial mattress stitches provides initial strength superior to single-row repair with arthroscopic Mason-Allen stitches under isometric cyclic loading as well as under ultimate loading conditions. Our results support the concept of double-row fixation with arthroscopic Mason-Allen/medial mattress stitches in rotator cuff tears with improvement of initial fixation strength and ultimate tensile load. Use of new polyblend polyethylene suture material seems not to increase the initial biomechanical aspects of the repair construct.

  6. Pothole Prevention and Innovative Repair

    DOT National Transportation Integrated Search

    2018-04-01

    Pothole repairs continue to be a major maintenance problem for many highway agencies. There is a critical need for finding long-lasting, cost-effective materials and construction technologies for repairing potholes. This research effort investigates ...

  7. Evaluation of current synthetic mesh materials in pelvic organ prolapse repair.

    PubMed

    Kanagarajah, Prashanth; Ayyathurai, Rajinikanth; Gomez, Christopher

    2012-06-01

    With increasing use of synthetic material in pelvic organ prolapse repair, the reporting and incidence of associated complications also have increased. The role of synthetic mesh in pelvic organ prolapse repair remains controversial and it is a therapeutic dilemma whether to continue its use in patients with poor native tissues, despite the recent public safety notification provided by the U.S. Food and Drug Administration. In this article, we review the biomaterials used in pelvic organ prolapse repair and discuss the outcomes and associated complications, paying emphasis to the benefits and the risks.

  8. 27 CFR 555.216 - Repair of magazines.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 3 2010-04-01 2010-04-01 false Repair of magazines. 555... EXPLOSIVES, DEPARTMENT OF JUSTICE EXPLOSIVES COMMERCE IN EXPLOSIVES Storage § 555.216 Repair of magazines. Before repairing the interior of magazines, all explosive materials are to be removed and the interior...

  9. Lawn and Garden Equipment Repair.

    ERIC Educational Resources Information Center

    Hardway, Jack; And Others

    This publication is designed to supplement the Comprehensive Small Engine Rapair guide by covering in detail all aspects of lawn and garden equipment repair not included in general engine repair or the repair of other small engines. It consists of instructional materials for both teachers and students, written in terms of student performance using…

  10. Laser bonding with ICG-infused chitosan patches: preliminary experiences in suine dura mater and vocal folds

    NASA Astrophysics Data System (ADS)

    Rossi, Francesca; Matteini, Paolo; Ratto, Fulvio; Pini, Roberto; Iacoangeli, Maurizio; Giannoni, Luca; Fortuna, Damiano; Di Cicco, Emiliano; Corbara, Sylwia; Dallari, Stefano

    2014-05-01

    Laser bonding is a promising minimally invasive approach, emerging as a valid alternative to conventional suturing techniques. It shows widely demonstrated advantages in wound treatment: immediate closuring effect, minimal inflammatory response and scar formation, reduced healing time. This laser based technique can overcome the difficulties in working through narrow surgical corridors (e.g. the modern "key-hole" surgery as well as the endoscopy setting) or in thin tissues that are impossible to treat with staples and/or stitches. We recently proposed the use of chitosan matrices, stained with conventional chromophores, to be used in laser bonding of vascular tissue. In this work we propose the same procedure to perform laser bonding of vocal folds and dura mater repair. Laser bonding of vocal folds is proposed to avoid the development of adhesions (synechiae), after conventional or CO2 laser surgery. Laser bonding application in neurosurgery is proposed for the treatment of dural defects being the Cerebro Spinal Fluid leaks still a major issue. Vocal folds and dura mater were harvested from 9-months old porks and used in the experimental sessions within 4 hours after sacrifice. In vocal folds treatment, an IdocyanineGreen-infused chitosan patch was applied onto the anterior commissure, while the dura mater was previously incised and then bonded. A diode laser emitting at 810 nm, equipped with a 600 μm diameter optical fiber was used to weld the patch onto the tissue, by delivering single laser spots to induce local patch/tissue adhesion. The result is an immediate adhesion of the patch to the tissue. Standard histology was performed, in order to study the induced photothermal effect at the bonding sites. This preliminary experimental activity shows the advantages of the proposed technique in respect to standard surgery: simplification of the procedure; decreased foreign-body reaction; reduced inflammatory response; reduced operating times and better handling in depth.

  11. Repair of orbital floor fractures with absorbable gelatin film.

    PubMed

    Mermer, R W; Orban, R E

    1995-01-01

    Many materials have been utilized for the repair of orbital floor fractures. Absorbable gelatin film is a bioabsorbable sheeting material that is manufactured from denatured collagen. This material is appropriate for the repair of smaller orbital floor defects (5 mm or less) and trapdoor-type fractures; it is used with larger defects as an interpositional graft material between the periorbital tissues and as an orbital floor reconstruction plate or mesh. Sixteen cases consisting of both types of defects were retrospectively examined clinically and radiographically. Satisfactory results were obtained in all of these cases, including no adverse ocular signs or implant rejection, good facial form, good function, and acceptable postoperative radiography results.

  12. Passive contribution of the rotator cuff to abduction and joint stability.

    PubMed

    Tétreault, Patrice; Levasseur, Annie; Lin, Jenny C; de Guise, Jacques; Nuño, Natalia; Hagemeister, Nicola

    2011-11-01

    The purpose of this study is to compare shoulder joint biomechanics during abduction with and without intact non-functioning rotator cuff tissue. A cadaver model was devised to simulate the clinical findings seen in patients with a massive cuff tear. Eight full upper limb shoulder specimens were studied. Initially, the rotator cuff tendons were left intact, representing a non-functional rotator cuff, as seen in suprascapular nerve paralysis or in cuff repair with a patch. Subsequently, a massive rotator cuff tear was re-created. Three-dimensional kinematics and force requirements for shoulder abduction were analyzed for each condition using ten abduction cycles in the plane of the scapula. Mediolateral displacements of the glenohumeral rotation center (GHRC) during abduction with an intact non-functioning cuff were minimal, but massive cuff tear resulted in significant lateral displacement of the GHRC (p < 0.013). Similarly, massive cuff tear caused increased superior migration of the GHRC during abduction compared with intact non-functional cuff (p < 0.01). From 5 to 30° of abduction, force requirements were significantly less with an intact non-functioning cuff than with massive cuff tear (p < 0.009). During abduction, an intact but non-functioning rotator cuff resulted in decreased GHRC displacement in two axes as well as lowered the force requirement for abduction from 5 to 30° as compared with the results following a massive rotator cuff tear. This provides insight into the potential biomechanical effect of repairing massive rotator cuff tears with a biological or synthetic "patch," which is a new treatment for massive cuff tear.

  13. Inferior sinus venosus defect: echocardiographic diagnosis and surgical approach.

    PubMed

    Crystal, Matthew A; Al Najashi, Khaled; Williams, William G; Redington, Andrew N; Anderson, Robert H

    2009-06-01

    We sought to define the inferior sinus venosus defect anatomically and document successful surgical approaches. We identified all patients previously given a diagnosis of an inferior sinus venosus defect at the Hospital for Sick Children, Toronto, Canada, between 1982 and 2005 by interrogating the cardiology and cardiac surgery databases. We included those having interatrial communications in which 1 or more of the right pulmonary veins drained to the inferior caval vein but retained connection with the left atrium, the rims of the oval fossa, and the walls of the coronary sinus, both being intact. We identified 11 children who had an interatrial communication meeting the criteria for and undergoing surgical repair of an inferior sinus venosus defect. Median age was 1.2 years; 6 (55%) subjects were male, and none were cyanotic. Transthoracic echocardiographic analysis was performed preoperatively in all children, revealing right ventricular dilation in all. Surgical repair was accomplished with a pericardial patch. A complex baffle was needed in 3 children to maintain unobstructed inferior caval and pulmonary venous return. The echocardiographic diagnosis was complete in only 5 patients, but all diagnoses were correct since the year 2000. In all children the observations at surgical intervention showed that the defect was a venoatrial communication involving drainage of the right pulmonary veins to the inferior caval vein while retaining connection to the left atrium. Transthoracic echocardiographic analysis should remain the modality of choice for diagnosis of the inferior sinus venosus defect. We report excellent surgical results with a patch or baffle, correctly redirecting the anomalous venoatrial connections.

  14. Strict Selection Criteria During Surgical Training Ensures Good Outcomes in Laparoscopic Omental Patch Repair (LOPR) for Perforated Peptic Ulcer (PPU).

    PubMed

    Shelat, Vishal G; Ahmed, Saleem; Chia, Clement L K; Cheah, Yee Lee

    2015-02-01

    Application of minimal access surgery in acute care surgery is limited due to various reasons. Laparoscopic omental patch repair (LOPR) for perforated peptic ulcer (PPU) surgery is safe and feasible but not widely implemented. We report our early experience of LOPR with emphasis on strict selection criteria. This is a descriptive study of all patients operated on for PPU at academic university-affiliated institutes from December 2010 to February 2012. All the patients who were operated on for LOPR were included as the study population and their records were studied. Perioperative outcomes, Boey score, Mannheim Peritonitis Index (MPI), and physiologic and operative severity scores for enumeration of mortality and morbidity (POSSUM) scores were calculated. All the data were tabulated in a Microsoft Excel spreadsheet and analyzed using Stata Version 8.x. (StataCorp, College Station, TX, USA). Fourteen patients had LOPR out of a total of 45 patients operated for the PPU. Mean age was 46 years (range 22-87 years). Twelve patients (86%) had a Boey score of 0 and all patients had MPI < 21 (mean MPI = 14). The predicted POSSUM morbidity and mortality were 36% and 7%, respectively. Mean ulcer size was 5 mm (range 2-10 mm), mean operating time was 100 minutes (range 70-123 minutes) and mean length of hospital stay was 4 days (range 3-6 days). There was no morbidity or mortality pertaining to LOPR. LOPR should be offered by acute care surgical teams when local expertise is available. This can optimize patient outcomes when strict selection criteria are applied.

  15. Factors predicting rotator cuff retears: an analysis of 1000 consecutive rotator cuff repairs.

    PubMed

    Le, Brian T N; Wu, Xiao L; Lam, Patrick H; Murrell, George A C

    2014-05-01

    The rate of retears after rotator cuff repair varies from 11% to 94%. A retear is associated with poorer subjective and objective clinical outcomes than intact repair. This study was designed to determine which preoperative and/or intraoperative factors held the greatest association with retears after arthroscopic rotator cuff repair. Cohort study; Level of evidence, 3. This study retrospectively evaluated 1000 consecutive patients who had undergone a primary rotator cuff repair by a single surgeon using an arthroscopic inverted-mattress knotless technique and who had undergone an ultrasound evaluation 6 months after surgery to assess repair integrity. Exclusion criteria included previous rotator cuff repair on the same shoulder, incomplete repair, and repair using a synthetic polytetrafluoroethylene patch. All patients had completed the modified L'Insalata Questionnaire and underwent a clinical examination before surgery. Measurements of tear size, tear thickness, associated shoulder injury, tissue quality, and tendon mobility were recorded intraoperatively. The overall retear rate at 6 months after surgery was 17%. Retears occurred in 27% of full-thickness tears and 5% of partial-thickness tears (P < .0001). The best independent predictors of retears were anteroposterior tear length (correlation coefficient r = 0.41, P < .0001), tear size area (r = 0.40, P < .0001), mediolateral tear length (r = 0.34, P < .0001), tear thickness (r = 0.29, P < .0001), age at surgery (r = 0.27, P < .0001), and operative time (r = 0.18, P < .0001). These factors produced a predictive model for retears: logit P = (0.039 × age at surgery in years) + (0.027 × tear thickness in %) + (1 × anteroposterior tear length in cm) + (0.76 × mediolateral tear length in cm) - (0.17 × tear size area in cm(2)) + (0.018 × operative time in minutes) -9.7. Logit P can be transformed into P, which is the chance of retears at 6 months after surgery. A rotator cuff retear is a multifactorial process with no single preoperative or intraoperative factor being overwhelmingly predictive of it. Nevertheless, rotator cuff tear size (tear dimensions, tear size area, and tear thickness) showed stronger associations with retears at 6 months after surgery than did measures of tissue quality and concomitant shoulder injuries.

  16. Combined Endoscopic Transorbital and Endonasal Repair of High Flow Orbital Apex/Middle Fossa Cerebrospinal Fluid Leak with a Nasoseptal Flap.

    PubMed

    Lucke-Wold, Brandon; Mendez, Gustavo; Cua, David; Akins, Paul; Gillham, Haley; Ciporen, Jeremy

    2018-01-01

    High flow orbital apex or middle fossa cerebrospinal fluid (CSF) leaks can be life threatening and complex to repair. These leaks associated with large dural defects are most commonly repaired with an open temporalis muscle patch or free flaps, but these flaps do not always stop the leak. A 65-year-old patient presented two years after orbital exenteration and radiation for squamous cell carcinoma. He developed multi-organism meningitis and pneumocephalus secondary to a large high-flow orbital apex/middle fossa CSF leak. To repair the leak, a combined endoscopic transorbital/endonasal approach with pedicled nasospetal flap and dermis fat graft was used. We describe the unique endoscopic technique that was used to treat the life threatening high flow orbital apex/middle fossa CSF leak. The technique allowed the use of the transposed pedicled flap, which is an alternative to the free flap in controlling CSF leak. Cisternogram post-operatively and clinical exam confirmed resolution of CSF leak. Although a critically ill patient at admission with a modified Rankin scale (MRS) of 5, he was discharged home on continued IV antibiotic therapy with a MRS of 3. Endoscopic evaluation at three months after treatment showed the effectiveness of the flap and he continued to improve clinically. This is the first case to describe a combined endoscopic transorbital and endonasal repair of high flow orbital apex/middle fossa CSF leak with a pedicled nasoseptal flap. These techniques can be utilized during initial reconstruction after orbital exenteration or as a salvage flap.

  17. Laparoscopic recurrent inguinal hernia repair during the learning curve: it can be done?

    PubMed

    Bracale, Umberto; Sciuto, Antonio; Andreuccetti, Jacopo; Merola, Giovanni; Pecchia, Leandro; Melillo, Paolo; Pignata, Giusto

    2017-01-01

    Trans-Abdominal Preperitoneal Patch (TAPP) repairs for Recurrent Hernia (RH) is a technically demanding procedure. It has to be performed only by surgeons with extensive experience in the laparoscopic approach. The purpose of this study is to evaluate the surgical safety and the efficacy of TAPP for RH performed in a tutoring program by surgeons in practice (SP). All TAPP repairs for RH performed by the same surgical team have been included in the study. We have evaluated the results of three SP during their learning curve in a tutoring program. Then these results have been compared to those of a highly experienced laparoscopic surgeon (Benchmark). A total of 530 TAPP repairs have been performed. Among these, 83 TAPP have been executed for RH, of which 43 by the Benchmark and 40 by the SP. When we have compared the outcomes of the Benchmark with those of SP, no significant difference has been observed about morbidity and recurrence while the operative time has been significantly longer for the SP. No intraoperative complications have occurred. International guidelines urge that TAPP repair for RH has to be performed only by surgeons with extensive experience in the laparoscopic approach. The results of the present study demonstrate that TAPP for RH could be performed also by surgeons in training during a learning program. We retain that an adequate tutoring program could lead a surgeon in practice to perform more complex hernia procedures without jeopardizing patient safety throughout the learning curve period. Laparoscopy, Learning Curve, Recurrent Hernia.

  18. Repairability of CAD/CAM high-density PMMA- and composite-based polymers.

    PubMed

    Wiegand, Annette; Stucki, Lukas; Hoffmann, Robin; Attin, Thomas; Stawarczyk, Bogna

    2015-11-01

    The study aimed to analyse the shear bond strength of computer-aided design and computer-aided manufacturing (CAD/CAM) polymethyl methacrylate (PMMA)- and composite-based polymer materials repaired with a conventional methacrylate-based composite after different surface pretreatments. Each 48 specimens was prepared from six different CAD/CAM polymer materials (Ambarino high-class, artBloc Temp, CAD-Temp, Lava Ultimate, Telio CAD, Everest C-Temp) and a conventional dimethacrylate-based composite (Filtek Supreme XTE, control) and aged by thermal cycling (5000 cycles, 5-55 °C). The surfaces were left untreated or were pretreated by mechanical roughening, aluminium oxide air abrasion or silica coating/silanization (each subgroup n = 12). The surfaces were further conditioned with an etch&rinse adhesive (OptiBond FL) before the repair composite (Filtek Supreme XTE) was adhered to the surface. After further thermal cycling, shear bond strength was tested, and failure modes were assessed. Shear bond strength was statistically analysed by two- and one-way ANOVAs and Weibull statistics, failure mode by chi(2) test (p ≤ 0.05). Shear bond strength was highest for silica coating/silanization > aluminium oxide air abrasion = mechanical roughening > no surface pretreatment. Independently of the repair pretreatment, highest bond strength values were observed in the control group and for the composite-based Everest C-Temp and Ambarino high-class, while PMMA-based materials (artBloc Temp, CAD-Temp and Telio CAD) presented significantly lowest values. For all materials, repair without any surface pretreatment resulted in adhesive failures only, which mostly were reduced when surface pretreatment was performed. Repair of CAD/CAM high-density polymers requires surface pretreatment prior to adhesive and composite application. However, four out of six of the tested CAD/CAM materials did not achieve the repair bond strength of a conventional dimethacrylate-based composite. Repair of PMMA- and composite-based polymers can be achieved by surface pretreatment followed by application of an adhesive and a conventional methacrylate-based composite.

  19. Fiber reinforcement of concrete structures

    DOT National Transportation Integrated Search

    2002-09-01

    Deterioration of concrete structures due to steel corrosion is a matter of considerable concern since the repairing of these structures proved to be a costly process. Repair and rehabilitation of the civil structures needs an enduring repair material...

  20. Wearable Inset-Fed FR4 Microstrip Patch Antenna Design

    NASA Astrophysics Data System (ADS)

    Zaini, S. R. Mohd; Rani, K. N. Abdul

    2018-03-01

    This project proposes the design of a wireless body area network (WBAN) microstrip patch antenna covered by the jeans fabric as the outer layer operating at the center frequency, fc of 2.40 GHz. Precisely, the microstrip patch antenna with the inset-fed edge technique is designed and simulated systematically by using the Keysight Advanced Design System (ADS) software where the FR4 board with the dielectric constant, ɛr of 4.70, dissipation factor or loss tangent, tan δ of 0.02 and height, h of 1.60 mm is the chosen dielectric substrate. The wearable microstrip patch antenna design is then fabricated using the FR4 printed circuit board (PCB) material, hidden inside the jeans fabric, and attached to clothing, such as a jacket accordingly. Simulation and fabrication measurement results show that the designed microstrip patch antenna characteristics can be applied significantly within the industrial, scientific, and medical (ISM) radio band, which is at fc = 2.40 GHz.

  1. Medial orbital wall reconstruction with flexible Ethisorb patches.

    PubMed

    Pohlenz, P; Adler, W; Li, L; Schmelzle, R; Klatt, J

    2013-03-01

    The aim of this study was to analyse the long-term result after reconstruction of the medial orbital wall with a flexible, biodegradable material (Ethisorb). During a period of almost 8 years, 31 patients with a medial orbital wall fracture were analysed retrospectively. Inclusion criteria were patients with a maximum size fracture of the orbital medial wall measuring 1.5-2 cm(2). Exophthalmos, enophthalmos, bulbus motility, diplopia and skin sensation were investigated over a period of 6 months. In all patients, the medial orbital wall was reconstructed with Ethisorb patches. No significant intraoperative complications were detected. No postoperative infection, abscess or seroma was found in any of the patients receiving an Ethisorb patch. The advantage of the semiflexibility of the Ethisorb patch is that it supplies an anatomically correct fit to the orbital medial wall but does not require fixation by screws or the use of sutures. The low rate of reported bulbus motility disturbance, diplopia, exophthalmos and enophthalmos demonstrates acceptable results after medial orbital wall reconstruction using the Ethisorb patch.

  2. Weld repair of carbon-moly coke drums without postweld heat treatment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moore, D.E.

    1996-06-01

    Investigations to evaluate weld repair of C-{1/2}Mo coke drums without postweld heat treatment (PWHT) are discussed in this paper. These investigations showed that shielded metal-arc welding (SMAW) without PWHT produced heat-affected zones (HAZ) and weld deposits with Charpy V-notch (CVN) impact toughness that exceeded the toughness of ex-service plate material. PWHT de-embrittles strain age-embrittled ex-service plate material. However, warming of drums to 200 F before putting in feed compensates for the omission of the de-embrittling PWHT. Additional testing showed that the de-embrittling PWHT did not significantly improve the fatigue properties of the ex-service plate material. As-welded SMAW repairs were foundmore » to be feasible for coke drums, and repairs have now been in service successfully for up to 2 years. The as-welded SMAW repairs were qualified on the basis of a 300 F preheat using small diameter electrodes for the first pass followed by larger diameter electrodes to temper the HAZ of the first pass. A half-bead technique was not used. Heat input is not precisely controlled as would be required for controlled deposition welding. Following the implementation of SMAW repairs without PWHT, the author extended the work to include as-welded repairs with automatic gas metal-arc welding (GMAW).« less

  3. Ability of Impedance-Based Health Monitoring To Detect Structural Damage of Propulsion System Components Assessed

    NASA Technical Reports Server (NTRS)

    Martin, Richard E.; Gyekenyesi, Andrew L.; Sawicki, Jerzy T.; Baaklini, George Y.

    2005-01-01

    Impedance-based structural-health-monitoring uses piezoelectric (PZT) patches that are bonded onto or embedded in a structure. Each individual patch behaves as both an actuator of the surrounding structural area as well as a sensor of the structural response. The size of the excited area varies with the geometry and material composition of the structure, and an active patch is driven by a sinusoidal voltage sweep. When a PZT patch is subjected to an electric field, it produces a mechanical strain; and when it is stressed, it produces an electric charge. Since the patch is bonded to the structure, driving a patch deforms and vibrates the structure. The structure then produces a localized dynamic response. This structural system response is transferred back to the PZT patch, which in turn produces an electrical response. The electromechanical impedance method is based on the principle of electromechanical coupling between the active sensor and the structure, which allows researchers to assess local structural dynamics directly by interrogating a distributed sensor array. Because of mechanical coupling between the sensor and the host structure, this mechanical effect is picked up by the sensor and, through electromechanical coupling inside the active element, is reflected in electrical impedance measured at the sensor s terminals.

  4. 3D modelling of squeeze flow of unidirectional and fabric composite inserts

    NASA Astrophysics Data System (ADS)

    Ghnatios, Chady; Abisset-Chavanne, Emmanuelle; Chinesta, Francisco; Keunings, Roland

    2016-10-01

    The enhanced design flexibility provided to the thermo-forming of thermoplastic materials arises from the use of both continuous and discontinuous thermoplastic prepregs. Discontinuous prepregs are patches used to locally strengthen the part. In this paper, we propose a new modelling approach for suspensions involving composite patches that uses theoretical concepts related to discontinuous fibres suspensions, transversally isotropic fluids and extended dumbbell models.

  5. The use of sustainable materials for quick repair of aging bridges : phase II final report.

    DOT National Transportation Integrated Search

    2012-02-01

    "During the last decade fiber reinforced polymer (FRP) materials have gained wide acceptance for repair and strengthening of existing infrastructures or to design new infrastructures due to their desirable properties (high strength to weight ratio, l...

  6. Materials and Procedures for Repair of Potholes in Asphalt-Surfaced Pavements : Manual of Practice (Updated)

    DOT National Transportation Integrated Search

    1999-12-01

    The Strategic Highway Research Program (SHRP) H-106 maintenance experiment and the Federal Highway Administration (FHWA) Long-Term Monitoring (LTM) of Pavement Maintenance Materials Test Sites project studied the repair of potholes in asphalt-surface...

  7. Endoscopic surgery for the antenatal treatment of myelomeningocele: the CECAM trial.

    PubMed

    Pedreira, Denise A L; Zanon, Nelci; Nishikuni, Koshiro; Moreira de Sá, Renato A; Acacio, Gregório L; Chmait, Ramen H; Kontopoulos, Eftichia V; Quintero, Rubén A

    2016-01-01

    A recent randomized clinical trial named Management of Myelomeningocele Study (MOMS trial) showed that prenatal correction of open spina bifida (OSB) via open fetal surgery was associated with improved infant neurological outcomes relative to postnatal repair, but at the expense of increased maternal morbidity. We sought to report the final results of our phase I trial (Cirurgia Endoscópica para Correção Antenatal da Meningomielocele [CECAM]) on the feasibility, safety, potential benefits, and side effects of the fetoscopic treatment of OSB using our unique surgical technique. Ten consecutive pregnancies with lumbosacral OSB were enrolled in the study. Surgeries were performed percutaneously under general anesthesia with 3 ports and partial carbon dioxide insufflation. After appropriate surgical positioning of the fetus, the neuroplacode was released with scissors and the skin was undermined to place a biocellulose patch over the lesion. The skin was closed over the patch using a single running stitch. Preoperative, postoperative, and postnatal magnetic resonance imaging were performed to assess hindbrain herniation. Neurodevelopmental evaluation was performed before discharge and at 3, 6, and 12 months. All cases were delivered by cesarean delivery, at which time the uterus was assessed for evidence of thinning or dehiscence. The median gestational age at the time of surgery was 27 weeks (range 25-28 weeks). Endoscopic repair was completed in 8 of 10 fetuses. Two cases were unsuccessful due to loss of uterine access. The mean gestational age at birth was 32.4 weeks with a mean latency of 5.6 weeks between surgery and delivery (range 2-8 weeks). There was 1 fetal and 1 neonatal demise, and 1 unsuccessful case underwent postnatal repair. Of the 7 infants available for analysis, complete reversal of hindbrain herniation occurred in 6 of 7 babies. Three babies required ventriculoperitoneal shunting or third ventriculostomy. Functional motor level was the same or better than the anatomical level in 6 of 7 cases. There was no significant maternal morbidity and no evidence of myometrial thinning or dehiscence. However, surgeries were complicated by premature rupture of membrane and prematurity. Our study suggests that the antenatal treatment of OSB using a fetoscopic approach and our unique surgical technique can result in a watertight seal, reversal of the hindbrain herniation, and better than expected motor function. Our technique differs substantially from the classic repair of OSB used in prior open fetal surgery and fetoscopic studies, in which the dura mater is dissected and the defect is closed in multiple layers. Instead, we use a biocellulose patch placed over the lesion and simple closure of the skin. As such, our technique is an alternative to the current paradigms in the antenatal treatment of OSB. Our clinical outcomes are in line with the results of our extensive prior animal work. Maternal benefits of our approach and technique include minimal morbidity and no myometrial legacy. Current limitations of the approach include potential loss of access, premature rupture of membranes, and attendant prematurity. Phase II trials are needed to prevent these complications and to further assess the risks and benefits of our distinct surgical approach and technique. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. 49 CFR 178.255-13 - Repair of tanks.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Repair of tanks. 178.255-13 Section 178.255-13 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY... Portable Tanks § 178.255-13 Repair of tanks. (a) Tanks failing to meet the test may be repaired and...

  9. 49 CFR 176.54 - Repairs involving welding, burning, and power-actuated tools and appliances.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Repairs involving welding, burning, and power... MATERIALS REGULATIONS CARRIAGE BY VESSEL General Operating Requirements § 176.54 Repairs involving welding..., repairs or work involving welding or burning, or the use of power-actuated tools or appliances which may...

  10. 49 CFR 176.54 - Repairs involving welding, burning, and power-actuated tools and appliances.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 2 2014-10-01 2014-10-01 false Repairs involving welding, burning, and power... MATERIALS REGULATIONS CARRIAGE BY VESSEL General Operating Requirements § 176.54 Repairs involving welding..., repairs or work involving welding or burning, or the use of power-actuated tools or appliances which may...

  11. 49 CFR 176.54 - Repairs involving welding, burning, and power-actuated tools and appliances.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 2 2013-10-01 2013-10-01 false Repairs involving welding, burning, and power... MATERIALS REGULATIONS CARRIAGE BY VESSEL General Operating Requirements § 176.54 Repairs involving welding..., repairs or work involving welding or burning, or the use of power-actuated tools or appliances which may...

  12. 49 CFR 176.54 - Repairs involving welding, burning, and power-actuated tools and appliances.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 2 2011-10-01 2011-10-01 false Repairs involving welding, burning, and power... MATERIALS REGULATIONS CARRIAGE BY VESSEL General Operating Requirements § 176.54 Repairs involving welding..., repairs or work involving welding or burning, or the use of power-actuated tools or appliances which may...

  13. 49 CFR 176.54 - Repairs involving welding, burning, and power-actuated tools and appliances.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 2 2012-10-01 2012-10-01 false Repairs involving welding, burning, and power... MATERIALS REGULATIONS CARRIAGE BY VESSEL General Operating Requirements § 176.54 Repairs involving welding..., repairs or work involving welding or burning, or the use of power-actuated tools or appliances which may...

  14. Glenn Refractory Adhesive for Bonding and Exterior Repair (GRABER) Developed for Repairing Shuttle Damage

    NASA Technical Reports Server (NTRS)

    Singh, Mrityunjay; Shpargel, Tarah P.

    2005-01-01

    Advanced in-space repair technologies for reinforced carbon/carbon composite (RCC) thermal protection system (TPS) structures are critically needed for the space shuttle Return To Flight (RTF) efforts. These technologies are also critical for the repair and refurbishment of thermal protection system structures of future Crew Exploration Vehicles of space exploration programs. The Glenn Refractory Adhesive for Bonding and Exterior Repair (GRABER) material developed at the NASA Glenn Research Center has demonstrated capabilities for repair of small cracks and damage in RCC leading-edge material. The concept consists of preparing an adhesive paste of desired ceramic in a polymer/phenolic resin matrix with appropriate additives, such as surfactants, and then applying the paste into the damaged or cracked area of the RCC composite components with caulking guns. The adhesive paste cures at 100 to 120 C and transforms into a high-temperature ceramic during simulated vehicle reentry testing conditions.

  15. Expedient Spall Repair Methods and Equipment for Airfield Pavements Preprint

    DTIC Science & Technology

    2009-08-01

    placement (3). RESEACH OBJECTIVES AND SCOPE The objective of this research was to develop one or more methods that will allow field personnel to...cores were used to perform in-situ tensile pull-off tests to evaluate the bond between the repair material and the substrate. Also, a series of 4...inch diameters cores were cut, and direct shear tests were performed on the repair material/substrate interface. Finally, all spalls were trafficked for

  16. Micromachined patch-clamp apparatus

    DOEpatents

    Okandan, Murat

    2012-12-04

    A micromachined patch-clamp apparatus is disclosed for holding one or more cells and providing electrical, chemical, or mechanical stimulation to the cells during analysis with the patch-clamp technique for studying ion channels in cell membranes. The apparatus formed on a silicon substrate utilizes a lower chamber formed from silicon nitride using surface micromachining and an upper chamber formed from a molded polymer material. An opening in a common wall between the chambers is used to trap and hold a cell for analysis using the patch-clamp technique with sensing electrodes on each side of the cell. Some embodiments of the present invention utilize one or more electrostatic actuators formed on the substrate to provide mechanical stimulation to the cell being analyzed, or to provide information about mechanical movement of the cell in response to electrical or chemical stimulation.

  17. Comparative Evaluation of Flexural Strength of Provisional Crown and Bridge Materials-An Invitro Study

    PubMed Central

    Garg, Sandeep

    2016-01-01

    Introduction Provisional restorations serve a key role as a functional and esthetic try-in for the design of the final prosthesis. During selection of materials for this restoration, clinicians must consider physical properties, ease of handling, cost and patient satisfaction and approval. Aim To evaluate and compare the flexural strength of provisional crown and bridge materials available commercially. Materials and Methods This in-vitro study was done to compare the flexural strength of six temporary crown and bridge materials available commercially at 24 hours, 8 days and after repair. Three poly methyl methacrylate based materials (DPI, SC10 and Trulon) and three bis-acrylic based composite resins (Protemp, Cooltemp and Luxatemp) were selected. A total of 72 specimens of dimensions 64mm×10mm×2.5mm were prepared from these materials (12 from each material) and divided into two groups (n=36). Specimens were stored in artificial saliva and were fractured after 24 hours and 8 days using Universal Testing Machine. The fractured samples from the 8 days study were then subjected to repair. A uniform space of 2mm and a 450 bevel was maintained for all the repaired samples for better distribution of forces. Flexural strength of these repaired samples was recorded using the same machine. Results were recorded and statistically analysed by one-way Anova and Post hoc tests. Result: Results revealed that there was decrease in flexural strength for all the materials tested from 24 hours to 8 days, though flexural strength between poly methyl methacrylate and bis-acrylic resins was similar at 24 hours and 8 days time interval. A substantial decrease was noticed in the strength of bis-acrylic composite resins after repair. Conclusion From the current study it can be suggested that though there is decrease in flexural strength for all the materials from 24 hours to 8 days, both can be used to fabricate the provisional restorations. However, in the event of a fracture of a bis-acrylic provisional restoration, it may be more advantageous to make a new provisional restoration than to repair the fractured one. PMID:27656568

  18. Materials and Procedures for Rapid Repair of Partial-Depth Spalls in Concrete Pavements : Manual of Practice (Update)

    DOT National Transportation Integrated Search

    1999-12-01

    The Strategic Highway Research Program (SHRP) H-106 maintenance experiment and the Federal Highway Administration (FHWA) Long-Term Monitoring (LTM) of Pavement Maintenance Materials Test Sites project studied the repair of partial depth spalls in con...

  19. Repair of dimethacrylate-based composite restorations by a silorane-based composite: a one-year randomized clinical trial.

    PubMed

    Popoff, D A V; Santa Rosa, T T A; Ferreira, R C; Magalhães, C S; Moreira, A N; Mjör, I A

    2012-01-01

    To investigate clinical performance of a low-shrinkage silorane-based composite resin when used for repairing conventional dimethacrylate-based composite restorations. Despite the continued development of resin-based materials, polymerization shrinkage and shrinkage stress still require improvement. A silorane-based monomer system was recently made available for dental restorations. This report refers to the use of this material for making repairs and evaluates the clinical performance of this alternative treatment. One operator repaired the defective dimethacrylate-based composite resin restorations that were randomly assigned to one of two treatment groups: control (n=50) repair with Adper SE Plus (3M/ESPE) and Filtek P60 Posterior Restorative (3M/ESPE), and test (n=50) repair with P90 System Adhesive Self-Etch Primer and Bond (3M/ESPE) and Filtek P90 Low Shrink Posterior Restorative (3M/ESPE). After one week, restorations were finished and polished. Two calibrated examiners (Kw≥0.78) evaluated all repaired restorations, blindly and independently, at baseline and one year. The parameters examined were marginal adaptation, anatomic form, surface roughness, marginal discoloration, postoperative sensitivity, and secondary caries. The restorations were classified as Alpha, Bravo, or Charlie, according to modified US Public Health Service criteria. Mann-Whitney and Wilcoxon tests were used to compare the groups. Of the 100 restorations repaired in this study, 93 were reexamined at baseline. Dropout from baseline to one-year recall was 11%. No statistically significant differences were found between the materials for all clinical criteria, at baseline or at one-year recall (p>0.05). No statistically significant differences were registered (p>0.05) for each material when compared for all clinical criteria at baseline and at one-year recall. The hypothesis tested in this randomized controlled clinical trial was accepted. After the one-year evaluations, the silorane-based composite exhibited a similar performance compared with dimethacrylate-based composite when used to make repairs.

  20. Collagen-Based Fillers as Alternatives to Cyanoacrylate Glue for the Sealing of Large Corneal Perforations.

    PubMed

    Samarawickrama, Chameen; Samanta, Ayan; Liszka, Aneta; Fagerholm, Per; Buznyk, Oleksiy; Griffith, May; Allan, Bruce

    2018-05-01

    To describe the use of collagen-based alternatives to cyanoacrylate glue for the sealing of acute corneal perforations. A collagen analog comprising a collagen-like peptide conjugated to polyethylene glycol (CLP-PEG) and its chemical crosslinker were tested for biocompatibility. These CLP-PEG hydrogels, which are designed to act as a framework for corneal tissue regeneration, were then tested as potential fillers in ex vivo human corneas with surgically created full-thickness perforations. Bursting pressures were measured in each of 3 methods (n = 10 for each condition) of applying a seal: 1) cyanoacrylate glue with a polyethylene patch applied ab externo (gold standard); 2) a 100-μm thick collagen hydrogel patch applied ab interno, and 3) the same collagen hydrogel patch applied ab interno supplemented with CLP-PEG hydrogel molded in situ to fill the remaining corneal stromal defect. Cyanoacrylate gluing achieved a mean bursting pressure of 325.9 mm Hg, significantly higher than the ab interno patch alone (46.3 mm Hg) and the ab interno patch with the CLP-PEG filler (86.6 mm Hg). All experimental perforations were sealed effectively using 100 μm hydrogel sheets as an ab interno patch, whereas conventional ab externo patching with cyanoacrylate glue failed to provide a seal in 30% (3/10) cases. An ab interno patch system using CLP-PEG hydrogels designed to promote corneal tissue regeneration may be a viable alternative to conventional cyanoacrylate glue patching for the treatment of corneal perforation. Further experimentation and material refinement is required in advance of clinical trials.

Top