Sample records for patellar prosthesis dislocation

  1. Neglected locked vertical patellar dislocation

    PubMed Central

    Gupta, Rakesh Kumar; Gupta, Vinay; Sangwan, Sukhbir Singh; Kamboj, Pradeep

    2012-01-01

    Patellar dislocations occurring about the vertical and horizontal axis are rare and irreducible. The neglected patellar dislocation is still rarer. We describe the clinical presentation and management of a case of neglected vertical patellar dislocation in a 6 year-old boy who sustained an external rotational strain with a laterally directed force to his knee. Initially the diagnosis was missed and 2 months later open reduction was done. The increased tension generated by the rotation of the lateral extensor retinaculum kept the patella locked in the lateral gutter even with the knee in full extension. Traumatic patellar dislocation with rotation around a vertical axis has been described earlier, but no such neglected case has been reported to the best of our knowledge. PMID:23162154

  2. Patellofemoral Arthritis After Lateral Patellar Dislocation: A Matched Population-Based Analysis.

    PubMed

    Sanders, Thomas L; Pareek, Ayoosh; Johnson, Nicholas R; Stuart, Michael J; Dahm, Diane L; Krych, Aaron J

    2017-04-01

    The rate of patellofemoral arthritis after lateral patellar dislocation is unknown. Purpose/Hypothesis: The purpose of this study was to compare the risk of patellofemoral arthritis and knee arthroplasty between patients who experienced a lateral patellar dislocation and matched individuals without a patellar dislocation. Additionally, factors predictive of arthritis after patellar dislocation were examined. The hypothesis was that the rate of arthritis is likely higher among patients who experience a patellar dislocation compared with those who do not. Cohort study; Level of evidence, 3. In this study, 609 patients who had a first-time lateral patellar dislocation between 1990 and 2010 were compared with an age- and sex-matched cohort of patients who did not have a patellar dislocation. Medical records were reviewed to collect information related to the initial injury, recurrent dislocation, treatment, and progression to clinically significant patellofemoral arthritis (defined as symptoms with degenerative changes on patellar sunrise radiographs). Factors associated with arthritis (age, sex, recurrence, osteochondral injury, trochlear dysplasia) were examined. At a mean follow-up of 12.3 ± 6.5 years from initial dislocation, 58 patients (9.5%) in the dislocation cohort were diagnosed with patellofemoral arthritis, corresponding to a cumulative incidence of arthritis of 1.2% at 5 years, 2.7% at 10 years, 8.1% at 15 years, 14.8% at 20 years, and 48.9% at 25 years. In the control cohort, 8 patients (1.3%) were diagnosed with arthritis, corresponding to a cumulative incidence of arthritis of 0% at 5 years, 0% at 10 years, 1.3% at 15 years, 2.9% at 20 years, and 8.3% at 25 years. Therefore, patients who experienced a lateral patellar dislocation had a significantly higher risk of developing arthritis (hazard ratio [HR], 7.8; 95% CI, 3.9-17.6; P < .001) than individuals without a patellar dislocation. However, the risk of knee arthroplasty was similar between groups

  3. 21 CFR 888.3580 - Knee joint patellar (hemi-knee) metallic resurfacing uncemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint patellar (hemi-knee) metallic... § 888.3580 Knee joint patellar (hemi-knee) metallic resurfacing uncemented prosthesis. (a) Identification. A knee joint patellar (hemi-knee) metallic resurfacing uncemented prosthesis is a device made of...

  4. Clinics in diagnostic imaging (163). Transient lateral patellar dislocation with trochlear dysplasia

    PubMed Central

    Zhang, Junwei; Lee, Chin Hwee

    2015-01-01

    A 14-year-old girl presented with left knee pain and swelling after an injury. Magnetic resonance (MR) imaging showed a transient lateral patellar dislocation with patellar osteochondral fracture, medial patellofemoral ligament tear and underlying femoral trochlear dysplasia. Open reduction and internal fixation of the osteochondral fracture, plication of the medial patellar retinaculum and lateral release were performed. As lateral patellar dislocation is often clinically unsuspected, an understanding of its characteristic imaging features is important in making the diagnosis. Knowledge of the various predisposing factors for patellar instability may also influence the choice of surgical management. We also discuss signs of acute injury and chronic instability observed on MR imaging, and the imaging features of anatomical variants that predispose an individual to lateral patellar dislocation. Treatment options and postsurgical imaging appearances are also briefly described. PMID:26512145

  5. Lateral patellar dislocation: mechanism of disease, radiographic presentation, and management.

    PubMed

    Abramov, Michael; Stock, Harlan

    2013-04-01

    Lateral patellar dislocation is a common injury occurring in young active adults. The mechanism is that of twisting injury to the knee on a planted foot with valgus stress. Several predisposing factors, including femoral trochlear dysplasia, patella alta, and lateralization of the tibial tuberosity, contribute to patellar instability and lateral patellar dislocation. Magnetic resonance (MR) imaging of the knee is the modality of choice to evaluate underlying bone contusion patterns, associated soft-tissue injuries, and additional complex ligamentous and osteochondral injuries, many of which are not apparent on conventional radiographs.

  6. Spontaneous superior patellar dislocation in young age: case report and reduction technique

    PubMed Central

    Umar, Muhammad

    2017-01-01

    Abstract Superior patellar dislocation is a very rare pathology, which happens in middle age. We report a case of spontaneous superior patellar dislocation, which occurred at 30 years of age. Differential diagnosis is patellar tendon rupture, which could be reliably excluded by clinical examination and radiographs. Reduction manoeuvres should be tried with diluted intra-articular local anaesthetic for hydrodilatation to gain mechanical advantage. Splinting the knee in gentle flexion is recommended if general anaesthetic is employed. Recurrent dislocation or osteochondral fractures warrants surgical treatment. PMID:28458846

  7. Management of traumatic patellar dislocation in a regional hospital in Hong Kong.

    PubMed

    Lee, H L; Yau, W P

    2017-04-01

    The role of surgery for acute patellar dislocation without osteochondral fracture is controversial. The aim of this study was to report the short-term results of management of patellar dislocation in our institute. Patients who were seen in our institution with patella dislocation from January 2011 to April 2014 were managed according to a standardised management algorithm. Pretreatment and 1-year post-treatment International Knee Documentation Committee score, Tegner activity level scale score, and presence of apprehension sign were analysed. A total of 41 patients were studied of whom 20 were first-time dislocators and 21 were recurrent dislocators. Among the first-time dislocators, there was a significant difference between patients who received conservative treatment versus surgical management. The conservative treatment group had a 33% recurrent dislocation rate, whereas there were no recurrent dislocations in the surgery group. There was no difference in Tegner activity level scale score or apprehension sign before and 1 year after treatment, however. Among the recurrent dislocators, there was a significant difference between those who received conservative treatment and those who underwent surgery. The recurrent dislocation rate was 71% in the conservative treatment group versus 0% in the surgery group. There was also significant improvement in International Knee Documentation Committee score from 67.7 to 80.0 (P=0.02), and of apprehension sign from 62% to 0% (P<0.01). A management algorithm for patellar dislocation is described. Surgery is preferable to conservative treatment in patients who have recurrent patellar dislocation, and may also be preferable for those who have an acute dislocation.

  8. Avulsion fracture of an ossified pes anserinus tendon post-lateral patellar dislocation.

    PubMed

    Albtoush, Omar M; Taib, Abtehag A; Horger, Marius; Springer, Fabian

    2018-05-01

    The pes anserinus is a common tendon comprising the tendinous insertions of the sartorius, gracilis, and semitendinosus muscles. It inserts at the anteromedial aspect of the tibia and plays a significant role in stabilization of the medial side of the knee joint. The current article presents a case with recurrent lateral patellar dislocations causing chronic stress along the medial knee stabilizers and consecutive enthesophyte formation at the insertion of the pes anserinus tendon that showed a transverse fracture upon a subsequent incident of traumatic lateral patellar dislocation. Avulsion injuries of the pes anserinus tendon are rarely encountered, and to our knowledge, association with recurrent lateral patellar dislocations has not been described before.

  9. Femoral neuropathy due to patellar dislocation in a theatrical and jazz dancer: a case report.

    PubMed

    Shin, Chris S; Davis, Brian A

    2005-06-01

    This case report describes a teenage female, high-level modern dancer who suffered multiple left patellar dislocations. Her history is atypical in that after her fifth dislocation, her recovery was hindered secondary to persistent weakness and atrophy of her quadriceps out of proportion to disuse alone. Electrodiagnostic studies and magnetic resonance imaging showed evidence of a subacute femoral neuropathy correlating chronologically with her most recent patellar dislocation. This case suggests that further diagnostic study may be warranted in patients with persistent quadriceps weakness or atrophy after a patellar dislocation, because this may suggest the presence of a femoral neuropathy. This is important because the strength training goals and precautions differ in disuse atrophy and a neuropathy. We believe this is the first reported case of a femoral neuropathy associated with the mechanism of a patellar dislocation.

  10. Total knee arthroplasty in a pseudoachondroplastic dwarfism patient with bilateral patellar dislocation.

    PubMed

    Oh, Kwang-Jun; Yoon, Jung-Ro; Yang, Jae-Hyuk

    2013-01-01

    Late presentation of congenital patellar dislocation with advanced osteoarthritis is rare. This article presents a case of a 59-year-old man with underlying pseudoachondroplastic dwarfism. Advanced osteoarthritis due to bilateral neglected congenital patellar dislocation was treated with total knee arthroplasty without patella relocation surgery. Two years later, the patient had an improvement in Knee Society scores, painless function, and stability. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. Vertical Patellar Dislocation: Reduction by the Push Up and Rotate Method, A Case Report and Literature Review.

    PubMed

    Ahmad Khan, Hayat; Bashir Shah, Adil; Kamal, Younis

    2016-11-01

    Patellar dislocation is an emergency. Vertical patellar dislocation is rare, often seen in adolescents and mostly due to sports injuries or high-velocity trauma. Few cases have been reported in the literature. Closed or open reduction under general anesthesia is often needed. We report a case of vertical locked patellar dislocation in a 26-year-old male, which was reduced by a simple closed method under spinal anaesthesia. A literature review regarding the various methods of treatment is also discussed. A 26-year-old male experienced a trivial accident while descending stairs, sustaining patellar dislocation. The closed method of reduction was attempted, using a simple technique. Reduction was confirmed and postoperative rehabilitation was started. Follow-up was uneventful. Vertical patellar dislocations are encountered rarely in the emergency department. Adolescents are not the only victims, and high-velocity trauma is not the essential cause. Unnecessary manipulation should be avoided. The closed reduction method is simple, but the surgeon should be prepared for open reduction.

  12. A magnetic resonance imaging study of abnormalities of the patella and patellar tendon that predispose children to acute patellofemoral dislocation.

    PubMed

    Yılmaz, Barış; Çiçek, Esin Derin; Şirin, Evrim; Özdemir, Güzelali; Karakuş, Özgün; Muratlı, Hasan Hilmi

    This study compared 20 children hospitalised with acute patellofemoral dislocation with an age-matched healthy control group with no history of knee problems or patellar dislocation. The following morphological parameters were significantly different between the groups: the mean patellar width and length, mean sulcus depth, mean patellar tendon width and total patellar volume. The magnetic resonance imaging findings of this study suggested that structurally smaller than normal patella and patellar tendon volumes are predisposing factors for acute patellofemoral dislocation. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. What Components Comprise the Measurement of the Tibial Tuberosity-Trochlear Groove Distance in a Patellar Dislocation Population?

    PubMed

    Tensho, Keiji; Akaoka, Yusuke; Shimodaira, Hiroki; Takanashi, Seiji; Ikegami, Shota; Kato, Hiroyuki; Saito, Naoto

    2015-09-02

    The tibial tuberosity-trochlear groove distance is used as an indicator for medial tibial tubercle transfer; however, to our knowledge, no studies have verified whether this distance is strongly affected by tubercle lateralization at the proximal part of the tibia. We hypothesized that the tibial tuberosity-trochlear groove distance is mainly affected by tibial tubercle lateralization at the proximal part of the tibia. Forty-four patients with a history of patellar dislocation and forty-four age and sex-matched controls were analyzed with use of computed tomography. The tibial tuberosity-trochlear groove distance, tibial tubercle lateralization, trochlear groove medialization, and knee rotation were measured and were compared between the patellar dislocation group and the control group. The association between the tibial tuberosity-trochlear groove distance and three other parameters was calculated with use of the Pearson correlation coefficient and partial correlation analysis. There were significant differences in the tibial tuberosity-trochlear groove distance (p < 0.001) and knee rotation (p < 0.001), but there was no difference in the tibial tubercle lateralization (p = 0.13) and trochlear groove medialization (p = 0.08) between the patellar dislocation group and the control group. The tibial tuberosity-trochlear groove distance had no linear correlation with tubercle lateralization (r = 0.21) or groove medialization (r = -0.15); however, knee rotation had a good positive correlation in the patellar dislocation group (r = 0.62). After adjusting for the remaining parameters, knee rotation strongly correlated with the tibial tuberosity-trochlear groove distance (r = 0.69, p < 0.001), whereas tubercle lateralization showed moderate significant correlations in the patellar dislocation group (r = 0.42; p = 0.005). Because the tibial tuberosity-trochlear groove distance is affected more by knee rotation than by tubercle malposition, its use as an indicator for

  14. [Tripolar arthroplasty for recurrent total hip prosthesis dislocation].

    PubMed

    Beaulé, P-E; Roussignol, X; Schmalzried, T-P; Udomkiat, P; Amstutz, H-C; Dujardin, F-H

    2003-05-01

    The purpose of this study was to assess the results of revision surgery for recurrent total hip prosthesis dislocation using a tripolar prosthesis composed of a conventional stem with a mobile head of an intermediary prosthesis measuring more than 40 mm and a modified cup. This technique was used in two centers in Rouen France and Los Angeles USA. Twenty-one hips in 21 patients were operated on. The mobile heads measured 40 to 47 mm. Mean patient age was 70 years (range 29-92). The indication for the tripolar prosthesis was reserved for extremely unstable hips in patients with major risk factors for recurrent dislocation. These 21 patients had experienced 95 dislocations. The acetabular cup was custom-made for the large-diameter heads. A cemented polyethylene cup was used in 14 cases and a press-fit metal-backed around a polyethylene insert in 7. The polyethylene thickness varied from 6.5 to 16 mm for the cemented cups and 4 to 5 mm for the press-fit cups. Fourteen femoral stems were left in place as were two press-fit cups where only the inserts were changed. Mean follow-up was 5.4 years (range 3-11.8). There has been no recurrent dislocation for 20 hips. One patient experienced a dislocation one week after surgery which required a second revision procedure to reposition the acetabular implant. Final outcome was good at 7.6 years for this hip. One patient who had not had any recurrent dislocation died 4 years after the revision surgery due to a cause unrelated to the prosthesis. Two patients were lost to follow-up at 3.7 and 6 years, both were pain free and had no radiological anomalies. Infection occurred in one patient undergoing chemotherapy for a myeloma; the head and neck had to be resected. For the 20 other patients, functional outcome, assessed with the UCLA score, showed improvement in pain (5.8 preoperatively, 9.2 at last follow-up), walking (4.8 and 8 respectively), function (4 and 6 respectively), and daily activities (3.3 and 5.2 respectively). A

  15. [Clinical significance of Q-angle under different conditions in recurrent patellar dislocation].

    PubMed

    Wang, Zhijie; Chen, You; Li, Anping; Long, Yi

    2014-01-01

    To investigate the clinical significance of Q-angle measuring under different conditions in female recurrent patellar dislocation female patients. Between August 2012 and March 2013, 10 female patients (11 knees) with recurrent patellar dislocation were collected as trial group; 20 female patients (20 knees) with simple meniscus injury were collected as control group at the same time. Q-angle was measured in extension, 30 degrees flexion, 30 degrees flexion with manual correction, and surgical correction in the trial group, and only in extension and 30 degrees flexion in the control group. Then the difference value of Q-angle between extension and 30 degrees flexion (Q-angle in extension subtracts Q-angle in 30 flexion) were calculated. Independent sample t-test was used to analyze Q-angle degrees in extension, 30 degrees flexion, and the changed degrees of 2 groups. The Q-angle between manual correction and surgical correction of the trial group was analyzed by paired t-test. The Q-angle in extension, Q-angle in 30 degrees flexion, and difference value of Q-angle between extension and 30 degrees flexion were (17.2 +/- 3.6), (14.3 +/- 3.0), and (2.9 +/- 1.9) degrees in the trial group and were (15.2 +/- 3.4), (14.4 +/- 3.5), and (0.8 +/- 1.7) degrees in the control group. No significant difference was found in Q-angle of extension or Q-angle of 30 degrees flexion between 2 groups (P > 0.05), but the difference value of Q-angle between extension and 30 degrees flexion in the trial group was significantly larger than that in the control group (t = 3.253, P = 0.003). The Q-angle in 30 degrees flexion with manual correction and surgical correction in the trial group was (19.8 +/- 3.4) degrees and (18.9 +/- 3.8) degrees respectively, showing no significant difference (t = 2.193, P = 0.053). When a female patient's Q-angle in 30 degrees flexion knee changes obviously compared with Q-angle in extension position, recurrent patellar dislocation should be considered. For

  16. I.S.Mu.L.T. first-time patellar dislocation guidelines

    PubMed Central

    Vetrano, Mario; Oliva, Francesco; Bisicchia, Salvatore; Bossa, Michela; De Carli, Angelo; Di Lorenzo, Luigi; Erroi, Davide; Forte, Alfonso; Foti, Calogero; Frizziero, Antonio; Gasparre, Giuseppe; Via, Alessio Giai; Innocenti, Bernardo; Longo, Umile Giuseppe; Mahmoud, Asmaa; Masiero, Stefano; Mazza, Daniele; Natali, Simone; Notarangelo, Christian; Osti, Leonardo; Padulo, Johnny; Pellicciari, Leonardo; Perroni, Fabrizio; Piccirilli, Eleonora; Ramponi, Carlo; Salvatore, Giuseppe; Panni, Alfredo Schiavone; Suarez, Tania; Tarantino, Umberto; Vittadini, Filippo; Vulpiani, Maria Chiara; Ferretti, Andrea; Maffulli, Nicola

    2017-01-01

    Summary Primary traumatic patellar dislocation is common, particularly in young active individuals. A consensus on its management is still lacking. The present work provides easily accessible guidelines to be considered as recommendations for a good clinical practice developed through a process of systematic review of the literature and expert opinion, to improve the quality of care and rationalize the use of resources. Level of evidence: Ia. PMID:28717605

  17. Descending genicular artery injury following transient lateral patellar dislocation.

    PubMed

    Silvestri, Andrea; Regis, Dario; Trivellin, Giacomo; Piccoli, Marco; Spina, Mauro; Magnan, Bruno; Sandri, Andrea

    2018-06-01

    Transient lateral patellar dislocation (TLPD) is a common lesion in young adults. Vascular injury as a complication of TLPD has not been previously described. We report a case of descending genicular artery (DGA) injury after TLPD. Immediate angiography demonstrated rupture of DGA. Embolization was performed with sudden interruption of bleeding. DGA injury should be considered as a complication after TLPD and prompt diagnosis and intervention are required. We propose selective embolization as a safe and effective procedure to stop bleeding.

  18. [Current status and expectations in the surgical treatment of recurrent lateral patellar dislocation].

    PubMed

    Zhao, Zhi-Dong; Li, Peng-Cui; Wei, Xiao-Chun

    2017-11-25

    Up to now, surgical treatment of recurrent lateral patellar dislocation mainly includes: medial patellofemoral ligament reconstruction, tibial tubercle osteotomy, trochleoplasty, lateral retinacular release, derotation osteotomy and so on . Clinical reports show that: the use of a single or combined with several methods have achieved ideal short to mid-term clinical outcomes. However, there is no consolidate criterion concerning the choices of different kinds of surgical ways for the treatment of individual recurrent lateral patellar dislocation. Meanwhile, with the wide use of MPFL reconstruction and other surgical options, there are more and more complications and failures that are worthy and necessary for us to pay attention to, even though its high success rate. The aim of this article is to make a systematic review of the application status of different surgical methods, collecting the positive results we have achieved, illuminating application keys of surgical techniques, guiding patient-specific therapy more precisely. Copyright© 2017 by the China Journal of Orthopaedics and Traumatology Press.

  19. Clinical Outcomes After the Nonoperative Management of Lateral Patellar Dislocations: A Systematic Review

    PubMed Central

    Moiz, Munim; Smith, Nick; Smith, Toby O.; Chawla, Amit; Thompson, Peter; Metcalfe, Andrew

    2018-01-01

    Background: The first-line treatment for patellar dislocations is often nonoperative and consists of physical therapy and immobilization techniques, with various adjuncts employed. However, the outcomes of nonoperative therapy are poorly described, and there is a lack of quality evidence to define the optimal intervention. Purpose: To perform a comprehensive review of the literature and assess the quality of studies presenting patient outcomes from nonoperative interventions for patellar dislocations. Study Design: Systematic review; Level of evidence, 4. Methods: The MEDLINE, AMED, Embase, CINAHL, Cochrane Library, PEDro, and SPORTDiscus electronic databases were searched through July 2017 by 3 independent reviewers. The PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines were followed. Study quality was assessed using the CONSORT (Consolidated Standards for Reporting Trials) criteria for randomized controlled trials and the Newcastle-Ottawa Scale for cohort studies and case series. Results: A total of 25 studies met our inclusion criteria, including 12 randomized controlled trials, 7 cohort studies, and 6 case series, consisting of 1066 patients. Studies were grouped according to 4 broad categories of nonoperative interventions based on immobilization, weightbearing status, quadriceps exercise type, and alternative therapies. The most commonly used outcome measure was the Kujala score, and the pooled redislocation rate was 31%. Conclusion: This systematic review found that patient-reported outcomes consistently improved after all methods of treatment but did not return to normal. Redislocation rates were high and close to the redislocation rates reported in natural history studies. There is a lack of quality evidence to advocate the use of any particular nonoperative technique for the treatment of patellar dislocations. PMID:29942814

  20. Relationship between bony tunnel and knee function in patients after patellar dislocation triple surgeries—a CT-based study

    NASA Astrophysics Data System (ADS)

    Qin, Le; Li, Mei; Yao, Weiwu; Shen, Ji

    2017-01-01

    We aimed to assess the CT-based bony tunnel valuations and their correlation with knee function after patellar dislocation triple surgeries. A retrospective study was performed on 66 patients (70 knees) who underwent patellar dislocation triple surgeries. The surgery was MPFL reconstruction primarily, combined with lateral retinaculum release and tibial tubercle osteotomy. CT examinations were performed to determine the femoral tunnel position, along with the patellar and femoral tunnel width 3 days and more than 1 year after operation for follow-up. Functional evaluation based on Kujala and Lysholm scores was also implemented. We compared tunnel width of the first and last examinations and correlated femoral tunnel position of the last examination with knee function. At the last follow-up, femoral tunnel position in the anterior-posterior direction was moderately correlated with knee function. Femoral tunnel position in the proximal-distal direction was not associated with postoperative knee function. Patellar and femoral tunnel width increased significantly at the last follow-up. However, no significant functional difference was found between patients with and without femoral tunnel enlargement. Our results suggested that the tunnel malposition in anterior-posterior position based on CT was related to impaired knee function during the follow-ups.

  1. Treatment of recurrent patellar dislocation via knee arthroscopy combined with C-arm fluoroscopy and reconstruction of the medial patellofemoral ligament.

    PubMed

    Li, Li; Wang, Hongbo; He, Yun; Si, Yu; Zhou, Hongyu; Wang, Xin

    2018-06-01

    Recurrent patellar dislocations were treated via knee arthroscopy combined with C-arm fluoroscopy, and reconstruction of the medial patellofemoral ligaments. Between October 2013 and March 2017, 52 cases of recurrent patellar dislocation [27 males and 25 females; age, 16-47 years (mean, 21.90 years)] were treated. Arthroscopic exploration was performed and patellofemoral joint cartilage injuries were repaired. It was subsequently determined whether it was necessary to release the lateral patellofemoral support belt. Pre-operative measurements were used to decide whether tibial tubercle osteotomy was required. Medial patellofemoral ligaments were reconstructed using autologous semitendinosus tendons. Smith and Nephew model 3.5 line anchors were used to double-anchor the medial patellofemoral margin. On the femoral side, the medial patellofemoral ligament was fixed using 7-cm, absorbable, interfacial compression screws. All cases were followed for 1-40 months (average, 21 months). The Q angle, tibial tuberosity trochlear groove distance, Insall-Salvati index, patellofemoral angle, lateral patellofemoral angle and lateral shift were evaluated on X-Ray images using the picture archiving and communication system. Subjective International Knee Documentation Committee (IKDC) knee joint functional scores and Lysholm scores were recorded. Post-operative fear was absent, and no patellar re-dislocation or re-fracture was noted during follow-up. At the end of follow-up, the patellofemoral angle (0.22±4.23°), lateral patellofemoral angle (3.44±1.30°), and lateral shift (0.36+0.14°) differed significantly from the pre-operative values (all, P<0.05). Furthermore, IKDC and Lysholm scores (87.84+3.74 and 87.48+3.35, respectively) differed significantly from the pre-operative values (both, P<0.05). These findings suggest that, in the short term, recurrent patellar dislocation treatment via knee arthroscopy combined with C-arm fluoroscopy and reconstruction of the medial

  2. Severe valgus deformity of the knee with permanent patellar dislocation associated with melorheostosis: a case report and review of the literature.

    PubMed

    Kitta, Yuki; Niki, Yasuo; Udagawa, Kazuhiko; Enomoto, Hiroyuki; Toyama, Yoshiaki; Suda, Yasunori

    2014-03-01

    We present a case of an 8-year-old boy diagnosed with melorheostosis who was suffering from severe genu valgum, permanent dislocation of the patella, knee flexion contracture and leg length shortening. Soft tissue contracture of the limb and subsequent joint deformities were reported to represent clinical manifestations of pediatric melorheostosis. As the epiphyseal plate had not closed, patellar reduction was achieved by soft tissue surgical stabilization, including lateral retinacular release, medial retinaculum plication, and transfer of the lateral half of the patellar tendon. At 4 years postoperatively, as a result of improved limb alignment and knee flexion contracture, the leg length shortening has improved, and the patient does not limp and participates in sports activities. Surgical intervention should be performed as early as possible, because genu valgum and external rotation of the tibia may deteriorate with age, rendering the patellar dislocation irreversible in patients with melorheostosis before epiphyseal closure. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Position of the prosthesis and the incidence of dislocation following total hip replacement.

    PubMed

    He, Rong-xin; Yan, Shi-gui; Wu, Li-dong; Wang, Xiang-hua; Dai, Xue-song

    2007-07-05

    Dislocation is the second most common complication of hip replacement surgery, and impact of the prosthesis is believed to be the fundamental reason. The present study employed Solidworks 2003 and MSC-Nastran software to analyze the three dimensional variables in order to investigate how to prevent dislocation following hip replacement surgery. Computed tomography (CT) imaging was used to collect femoral outline data and Solidworks 2003 software was used to construct the cup model with variabilities. Nastran software was used to evaluate dislocation at different prosthesis positions and different geometrical shapes. Three dimensional movement and results from finite element method were analyzed and the values of dislocation resistance index (DRI), range of motion to impingement (ROM-I), range of motion to dislocation (ROM-D) and peak resisting moment (PRM) were determined. Computer simulation was used to evaluate the range of motion of the hip joint at different prosthesis positions. Finite element analysis showed: (1) Increasing the ratio of head/neck increased the ROM-I values and moderately increased ROM-D and PRM values. Increasing the head size significantly increased PRM and to some extent ROM-I and ROM-D values, which suggested that there would be a greater likelihood of dislocation. (2) Increasing the anteversion angle increased the ROM-I, ROM-D, PRM, energy required for dislocation (ENERGY-D) and DRI values, which would increase the stability of the joint. (3) As the chamber angle was increased, ROM-I, ROM-D, PRM, Energy-D and DRI values were increased, resulting in improved joint stability. Chamber angles exceeding 55 degrees resulted in increases in ROM-I and ROM-D values, but decreases in PRM, Energy-D, and DRI values, which, in turn, increased the likelihood of dislocation. (4) The cup, which was reduced posteriorly, reduced ROM-I values (2.1 -- 5.3 degrees ) and increased the DRI value (0.073). This suggested that the posterior high side had the

  4. RANDOMIZED PROSPECTIVE STUDY ON TRAUMATIC PATELLAR DISLOCATION: CONSERVATIVE TREATMENT VERSUS RECONSTRUCTION OF THE MEDIAL PATELLOFEMORAL LIGAMENT USING THE PATELLAR TENDON, WITH A MINIMUM OF TWO YEARS OF FOLLOW-UP.

    PubMed

    Bitar, Alexandre Carneiro; D'Elia, Caio Oliveira; Demange, Marco Kawamura; Viegas, Alexandre Christo; Camanho, Gilberto Luis

    2011-01-01

    The aim of this study was to compare the surgical results from reconstruction of the medial patellofemoral ligament (MPFL) with non-operative treatment of primary patellar dislocation. Thirty-nine patients (41 knees) with patellar dislocation were randomized into two groups. One group was treated conservatively (immobilization and physiotherapy) and other was treated surgically with reconstruction of the MPFL, and the results were evaluated with a minimum follow-up of two years. The Kujala questionnaire was applied to assess pain and quality of life, and recurrences were evaluated. Pearson's chi-square test and Fisher's exact test were used in the statistical evaluation. The statistical analysis showed that the mean Kujala score was significantly lower in the conservative group (70.8), compared with the mean value in the surgical group (88.9), with p = 0.001. The surgical group presented a higher percentage of "good/excellent" Kujala score results (71.43%) than in the conservative group (25.0%), with p = 0.003. The conservative group presented a greater number of recurrences (35% of the cases), while in the surgical group there were no reports of recurrences and/or subluxation. Treatment with reconstruction of the medial patellofemoral ligament using the patellar tendon produced better results, based on the analysis of post-treatment recurrences and the better final results from the Kujala questionnaire after a minimum follow-up period of two years.

  5. Trochleoplasty as a Solitary Treatment for Recurrent Patellar Dislocation Results in Good Clinical Outcome in Adolescents.

    PubMed

    Camathias, Carlo; Studer, Katrin; Kiapour, Ata; Rutz, Erich; Vavken, Patrick

    2016-11-01

    The essential static patellar stabilizer is a normal-shaped trochlear groove. A dysplastic groove destabilizes the patella. Trochleoplasty approaches this underlying condition and reshapes the trochlea. However, studies have reported on trochleoplasty for revision cases or as accompanied by other interventions. The effect of trochleoplasty alone remains unexplained. To introduce trochleoplasty as a stand-alone treatment for recurrent patellar dislocation and to compare its pre- to postoperative functional and clinical variables. Case series; Level of evidence, 4. A trochleoplasty was performed in 50 knees (27 right) in 44 patients (30 females; mean ± SD age, 15.6 ± 2.0 years). The indication for surgery was recurrent patellar dislocation not responding to nonoperative treatment (>6 months), with types B through D dysplasia and closed or closing physes in adolescents aged 10 to 20 years. Assessment included J-sign and apprehension test, Kujala and Lysholm scores, patients' subjective assessment and activity level according to the International Knee Documentation Committee questionnaire, and patients' overall satisfaction. The Caton-Deschamps ratio and the lateral condyle index were measured. Pre- versus postoperative values were compared with a paired Wilcoxon signed-rank test. The minimum follow-up was 24 months (33 ± 10.6 months). The Kujala score improved from 71 preoperatively to 92 postoperatively (P < .001) and the Lysholm score from 71 to 95 (P < .001). Patients' subjective assessment improved at the final follow-up as compared with that preoperatively (P < .001). Most patients enhanced their activity (P < .001), and their overall satisfaction increased postoperatively (P < .001). Preoperatively, there was a positive J-sign in 45 knees and a positive apprehension test in 41 knees. Both markers disappeared postoperatively in 39 and 33 knees, respectively, leaving 6 knees with a positive J-sign and 8 knees with a positive apprehension test (P < .001). One

  6. Lateral patellar retinaculum reconstruction for medial patellar instability following lateral retinacular release: a case report.

    PubMed

    Udagawa, Kazuhiko; Niki, Yasuo; Matsumoto, Hiroaki; Matsumoto, Hideo; Enomoto, Hiroyuki; Toyama, Yoshiaki; Suda, Yasunori

    2014-01-01

    Lateral retinacular release is still being performed in patients with recurrent patellar dislocation as an additional procedure with distal realignment or medial patellofemoral ligament (MPFL) reconstruction. However, consensus remains lacking regarding suitable indications for lateral retinacular release. A 20-year-old woman presented with patellar instability in both medial and lateral directions after undergoing lateral retinacular release with MPFL reconstruction. She displayed inherent systemic joint laxity meeting all seven Carter-Wilkinson criteria. Simultaneous MPFL revision and lateral retinaculum reconstruction successfully improved patellar instability in both directions. This case provides an example of iatrogenic medial patellar instability after failed lateral retinacular release. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. [Significance of lateral release in the therapy of patellar chondromalacia].

    PubMed

    Krüger, T; Göbel, F; Huschenbett, A; Hein, W

    2002-10-01

    A retrospective study was performed in 26 patients who underwent an operation for femoro-patellar pain due to a patellar chondromalacia with or without minor patellar dislocation/lateral pressure syndrome. The average age of the patients was 28.5 (15-39) years. 22 of the 26 patients revealed minor chondral damages of the stages 1 and 2 according to Outerbridge. In 12 patients ("lavage" group), an arthroscopic joint debridement only was carried out, while an additional open, lateral retinaculum release was made in 14 patients ("lateral release" group). The patella's distance of dislocation according to Hepp was reduced on an average of 3.0 (0-7) mm (p = 0.0019). The results of Bentley's score obtained during the follow-up interval on an average of 30.1 (9 to 60) months were almost identical for both groups. "Good" and "very good" results were achieved in the "lavage" group (83.3 %) and "lateral release" group (78.6 % of the patients). Lateral release should be used in cases of patellar decentration between 5 and 10 mm and adequate pain symptoms. The post-operative distance of dislocation should be less than 5 mm. Under such conditions and with minor chondral damage, a combined approach by using an arthroscopic joint debridement and open lateral release is promising to treat a patellar dislocation/lateral pressure syndrome.

  8. What is the chance that a patella dislocation will happen a second time: update on the natural history of a first time patella dislocation in the adolescent.

    PubMed

    Seitlinger, Gerd; Ladenhauf, Hannah N; Wierer, Guido

    2018-02-01

    Patellar instability occurs mainly in young patients and shows a high incidence of concomitant cartilage injuries. Recently there has been a strong attempt to identify risk factors and enhance imaging techniques to detect patients with an increased risk for recurrent patella dislocation.We describe current findings on factors associated with recurrent patella dislocation in the adolescent. Trochlear dysplasia, patellar height, patellar tilt, tibial tuberosity-trochlear groove distance, skeletal maturity, and history of contralateral patellar dislocation are well known significant risk factors for recurrence in adolescent patients. Predictive models to calculate risk of recurrence have been reported recently. The Patellar Instability Severity Score was the first to include demographic and anatomic factors, which is of major value when counseling patients and relatives. Several classification systems to predict the rate of recurrence after primary patella dislocation have been presented over the last years. Anatomic risk factors such as skeletal immaturity, trochlear morphology, patellar height, patellar tilt, and elevated tibial tuberosity-trochlear groove distance have been investigated. However, there is still a lack of knowledge as to how single risk factors or their interaction with each other may contribute.

  9. Lateralization of the Tibial Tubercle in Recurrent Patellar Dislocation: Verification Using Multiple Methods to Evaluate the Tibial Tubercle.

    PubMed

    Tensho, Keiji; Shimodaira, Hiroki; Akaoka, Yusuke; Koyama, Suguru; Hatanaka, Daisuke; Ikegami, Shota; Kato, Hiroyuki; Saito, Naoto

    2018-05-02

    The tibial tubercle deviation associated with recurrent patellar dislocation (RPD) has not been studied sufficiently. New methods of evaluation were used to verify the extent of tubercle deviation in a group with patellar dislocation compared with that in a control group, the frequency of patients who demonstrated a cutoff value indicating that tubercle transfer was warranted on the basis of the control group distribution, and the validity of these methods of evaluation for diagnosing RPD. Sixty-six patients with a history of patellar dislocation (single in 19 [SPD group] and recurrent in 47 [RPD group]) and 66 age and sex-matched controls were analyzed with the use of computed tomography (CT). The tibial tubercle-posterior cruciate ligament (TT-PCL) distance, TT-PCL ratio, and tibial tubercle lateralization (TTL) in the SPD and RPD groups were compared with those in the control group. Cutoff values to warrant 10 mm of transfer were based on either the minimum or -2SD (2 standard deviations below the mean) value in the control group, and the prevalences of patients in the RPD group with measurements above these cutoff values were calculated. The area under the curve (AUC) in receiver operating characteristic (ROC) curve analysis was used to assess the effectiveness of the measurements as predictors of RPD. The mean TT-PCL distance, TT-PCL ratio, and TTL were all significantly greater in the RPD group than in the control group. The numbers of patients in the RPD group who satisfied the cutoff criteria when they were based on the minimum TT-PCL distance, TT-PCL ratio, and TTL in the control group were 11 (23%), 7 (15%), and 6 (13%), respectively. When the cutoff values were based on the -2SD values in the control group, the numbers of patients were 8 (17%), 6 (13%), and 0, respectively. The AUC of the ROC curve for TT-PCL distance, TT-PCL ratio, and TTL was 0.66, 0.72, and 0.72, respectively. The extent of TTL in the RPD group was not substantial, and the percentages

  10. REHABILITATION FOLLOWING MEDIAL PATELLOFEMORAL LIGAMENT RECONSTRUCTION FOR PATELLAR INSTABILITY

    PubMed Central

    Prohaska, Daniel

    2017-01-01

    Patellar instability is a common problem seen by physical therapists, athletic trainers and orthopedic surgeons. Although following an acute dislocation, conservative rehabilitation is usually the first line of defense; refractory cases exist that may require surgical intervention. Substantial progress has been made in the understanding of the medial patellofemoral ligament (MPFL) and its role as the primary stabilizer to lateral patellar displacement. Medial patellofemoral ligament disruption is now considered to be the essential lesion following acute patellar dislocation due to significantly high numbers of ruptures following this injury. Evidence is now mounting that demonstrates the benefits of early reconstruction with a variety of techniques. Recently rehabilitation has become more robust and progressive due to our better understanding of soft tissue reconstruction and repair techniques. The purpose of this manuscript is to describe the etiology of patellar instability, the anatomy and biomechanics and examination of patellofemoral instability, and to describe surgical intervention and rehabilitation following MPFL rupture. Level of Evidence 5 PMID:28593102

  11. [Patellar bone deficiency in revision total knee arthroplasty].

    PubMed

    Kloiber, J; Goldenitsch, E; Ritschl, P

    2016-05-01

    Patellar bone deficiency in revision total knee arthroplasty (TKA) determines the surgical procedure. Different reconstructive and ablative techniques, dependent on the remaining bone stock, are described. The primary patella implant can be retained in up to 50 % of revision situations. Reasons for replacement are aseptic and septic loosening, implant failure, expanding osteolysis, maltracking of the patella and "metal-backed" prosthesis. The aim of the reconstruction is the stable fixation and proper tracking of the implant by restoring the extensor mechanism. Dependent on the extent of bone loss and the availability of a patellar rim, the following surgical procedures are recommended. When the remaining bone thickness is 10 mm or more: implantation of a polyethylene "onlay-type" patella; when it is between 6-9 mm and there is an intact patellar rim: reconstruction with a biconvex "inlay-type" patella implant, where the biconvex shape replaces the bone defect partially. When there is deficient bone stock (less than 6 mm) or no cortical patellar rim then augmenting procedures with autologous spongiosa and procedures such as "impaction bone grafting", "trabecular metal" prosthesis, where the trabecular part of the implant serves as the base for the cemented polyethylene button, "gull-wing" osteotomy, which is an adapting and configuring technique of osteotomy; and in exceptional cases patelloplasty or patellectomy are used. Regarding the importance of the patellar component in biomechanics of the joint and function of the extensor mechanism, the reconstruction of the patella should be the primary aim. Patelloplasty or patellectomy should be avoided.

  12. Revision Surgery in Permanent Patellar Dislocation in DiGeorge Syndrome

    PubMed Central

    Berruto, Massimo; Parente, Andrea; Ferrua, Paolo; Pasqualotto, Stefano; Uboldi, Francesco; Usellini, Eva

    2015-01-01

    A 29-year-old patient, suffering from DiGeorge syndrome, came to our attention with a history of persistent pain and patellar instability in the left knee after failure of arthroscopic lateral release and Elmslie-Trillat procedure. The patient was unable to walk without crutches and severely limited in daily living activities. Because of arthritic changes of the patellofemoral joint and the failure of previous surgeries it was decided to perform only an open lateral release and medial patellofemoral ligament (MPFL) reconstruction using a biosynthetic ligament in order to obtain patellofemoral stability. At one year post-op range of motion (ROM) was 0–120 with a firm end point at medial patellar mobilization; patella was stable throughout the entire ROM. All the scores improved and she could be able to perform daily activity without sensation of instability. Bilateral patellar subluxation and systemic hyperlaxity are characteristics of syndromic patients and according to literature can be also present in DiGeorge syndrome. MPFL reconstruction with lateral release was demonstrated to be the correct solution in the treatment of patellar instability in this complex case. The choice of an artificial ligament to reconstruct the MPFL was useful in this specific patient with important tissue laxity due to her congenital syndrome. PMID:26783479

  13. Quantitative stress radiography of the patella and evaluation of patellar laxity before and after lateral release for recurrent dislocation patella.

    PubMed

    Niimoto, Takuya; Deie, Masataka; Adachi, Nobuo; Usman, Muhammad Andry; Ochi, Mitsuo

    2014-10-01

    The aims of the present controlled clinical study were to (1) compare patella laxity determined in the outpatient clinic with that in anaesthetized patients and (2) evaluate patella laxity before and after lateral release. The study evaluated data on 33 knees from 33 patients (average age 19.7 years) between 2007 and 2011. All patients were diagnosed with recurrent dislocation of the patella. Patellar stability was evaluated in each patient thrice: patellas were first imaged in the outpatient clinic prior to surgery at 45° knee flexion with 20 N stress from the medial to lateral side and from the lateral to medial side; then, at the time of surgery, patella stress images were obtained in the same manner before and after the lateral release procedure. Radiological assessments were performed using the medial stress shift ratio (MSSR) and lateral stress shift ratio (LSSR). There were no significant differences in the LSSR and MSSR before surgery (outpatient data) and in anaesthetized patients before the lateral release procedure. Furthermore, there was no significant difference in MSSR at the time of surgery before and after the lateral release procedure. However, LSSR increased significantly after the lateral release procedure. The results of the present study suggest that quantitative patella stress radiography in the outpatient clinic is useful when it comes to investigating laxity of the patella, and that lateral release significantly increases lateral, but not medial, laxity in patients with recurrent patellar dislocation. IV.

  14. [Patellar instability : diagnosis and treatment].

    PubMed

    Ngo, Trieu Hoai Nam; Martin, Robin

    2017-12-13

    The aim of this paper is to present recent advances in surgical management of patellar instability. Several anatomical factors were reported to promote instability. We propose to classify them in two groups. Extra articular factors are valgus and torsion deformity. Articular factors include trochlea and patella dysplasia, tibial tubercle lateralization and medial patellofemoral ligament (MPFL) insufficiency. Acute patellar dislocations are treated conservatively, with exception for osteochondral and MPFL avulsion fractures that require acute reinsertion. Surgery is considered for recurrent instability. As we aim for a correction of all contributing elements, we prefer a two stages approach. Extra articular factors are treated first by osteotomy, followed by articular factors after 4-6 months. This allows separate rehabilitation protocols.

  15. 21 CFR 888.3580 - Knee joint patellar (hemi-knee) metallic resurfacing uncemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... degenerative and posttraumatic patellar arthritis. (2) Class III when intended for uses other than treatment of degenerative and posttraumatic patellar arthritis. (c) Date PMA or notice of completion of a PDP is required. A...

  16. 21 CFR 888.3580 - Knee joint patellar (hemi-knee) metallic resurfacing uncemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... degenerative and posttraumatic patellar arthritis. (2) Class III when intended for uses other than treatment of degenerative and posttraumatic patellar arthritis. (c) Date PMA or notice of completion of a PDP is required. A...

  17. 21 CFR 888.3580 - Knee joint patellar (hemi-knee) metallic resurfacing uncemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... degenerative and posttraumatic patellar arthritis. (2) Class III when intended for uses other than treatment of degenerative and posttraumatic patellar arthritis. (c) Date PMA or notice of completion of a PDP is required. A...

  18. 21 CFR 888.3580 - Knee joint patellar (hemi-knee) metallic resurfacing uncemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... degenerative and posttraumatic patellar arthritis. (2) Class III when intended for uses other than treatment of degenerative and posttraumatic patellar arthritis. (c) Date PMA or notice of completion of a PDP is required. A...

  19. Sonography on injury of the medial patellofemoral ligament after acute traumatic lateral patellar dislocation: Injury patterns and correlation analysis with injury of articular cartilage of the inferomedial patella.

    PubMed

    Zhang, Guang-Ying; Zheng, Lei; Shi, Hao; Qu, Su-Hui; Ding, Hong-Yu

    2013-12-01

    The purpose of this study was to investigate the accuracy of high-frequency ultrasonography in the diagnosis of injuries of medial patellofemoral ligaments (MPFLs), analyse the characteristics of MPFL injury and correlations between injury of the MPFL and articular cartilage of the inferomedial patella in patients with acute traumatic lateral patellar dislocation. High-frequency sonographic images of 49 patients with acute traumatic lateral patellar dislocations treated surgically were reviewed. The χ(2) tests were performed for statistical analysis. Twenty-eight cases of complete MPFL tear and 21 cases of partial MPFL tear were identified in operation, with 27 cases of MPFL tear located at their femoral attachment, 21 cases of tear at the patellar attachment and one case of midsubstance tear. The diagnostic accuracy of sonography regarding partial MPFL tear and complete MPFL tear was 89.8% and 89.8%. Among the patients with MPFL tear at the patellar attachment, eight and six cases were concomitant with chondral and osteochondral lesions in the inferomedial patella, respectively, in contrast to nine and six cases in patients with MPFL tear at the femoral attachment, respectively. There was no significant difference between the two locations described above regarding the prevalence rates of chondral or osteochondral lesions of the inferomedial patella (P=0.732, P=0.614). Among the patients with complete MPFL tear, 12 and 10 cases were concomitant with chondral and osteochondral lesions in the inferomedial patella, respectively, while six and two cases were concomitant with partial MPFL tear. There was no significant difference between the two types of injuries discussed above on the prevalence rates of chondral lesions of the inferomedial patella (P=0.305), but the prevalence rate of osteochondral lesions between the two types of injuries discussed above was statistically different (P=0.035). The MPFL is most easily injured at the femoral attachment, secondly at

  20. Management of comminuted patellar fracture with non-absorbable suture cerclage and Nitinol patellar concentrator.

    PubMed

    Lue, Tan Hong; Feng, Liu Wei; Jun, Wang Ming; Yin, Li Wu

    2014-12-01

    To evaluate the effectiveness and safety of a fixation technique for comminuted patellar fracture using non-absorbable suture cerclage and nickel-titanium patellar concentrator (Ni-Ti PC). Twenty-nine consecutive patients with displaced comminuted patellar fractures accepted internal fixation procedure using Ni-Ti PC augmented with different types of non-absorbable suture cerclage. During follow-up, the clinical grading scales of Böstman, including range of movement, pain, work, atrophy, assistance in walking, effusion, giving way, and stair-climbing, were used to evaluate the clinical results. Complications including implant loosening, fragment displacement, bone nonunion, infection, breakage of the implants, painful hardware, and post-traumatic osteoarthritis were also assessed. Patients were followed up for a mean period of 27 months. The bone union radiographically occurred approximately 2.5 months without implant loosening and fragment displacement. According to Böstman method, satisfactory results were obtained, and the mean score at final follow-up was 28 (range 20–30) points. Twenty-two patients with excellent results had mean score of 29.8 ± 0.5 (range 28–30) and seven patients with good results had mean score of 22.7 ± 3.14 (range 20–27). No postoperative complications, such as infection, dislocation, breakage of the implants, painful hardware, and post-traumatic osteoarthritis, were observed. Ni-Ti PC fixation with non-absorbable suture cerclage is a feasible approach for comminuted patellar fractures. Firm fixation with this technique resulted in satisfactory outcomes without obvious complications.

  1. [Clinical study on patellar replacement in total knee arthroplasty].

    PubMed

    Bao, Liang; Gao, Zhihui; Shi, Xiaoqiang; Fang, Xiaomin; Jin, Qunhua

    2013-01-01

    To evaluate the influence of patellar replacement on total knee arthroplasty by comparing with non patellar replacement. Between September 2010 and November 2010, 63 patients (63 knees) with osteoarthritis who met the selection criteria and underwent total knee arthroplasty, were randomly divided into 2 groups: patellar replacement in 32 cases (replacement group), non patellar replacement in 31 cases (non patellar replacement group). There was no significant difference in gender, age, disease duration, osteoarthritis grading, the clinical and functional scores of American Knee Society Score (KSS), the patellar tilt angle, tibiofemoral angle, and patellar ligament ratio between 2 groups (P > 0.05), they were comparable. After 6 weeks, 3, 6, and 12 months of operation, clinical and imaging evaluation methods were used to assessment the effectiveness. Primary healing of incision was obtained in all patients of 2 groups. Deep venous thrombosis occurred in 6 cases of replacement group and in 8 cases of non patellar replacement group. All patients were followed up 12 months. The postoperative incidence of anterior knee pain in replacement group was significantly lower than that in non patellar replacement group (P < 0.05) at 3, 6, and 12 months after operation. No significant difference was found in the postoperative KSS clinical score between 2 groups at each time point (P > 0.05). The joint function score of the replacement group was significantly higher than that of the non patellar replacement group at the other time point (P < 0.05) except the score at 6 weeks and 3 months. Significant difference was found in the patella score between 2 groups at 12 months (P < 0.05), but no significant difference at the other time points (P > 0.05). X-ray film showed no patellar fracture and dislocation, or loosening and breakage of internal fixation. At 12 months after operation, the tibiofemoral angle, the patellar ligament ratio, and the patellar tilt angle showed no significant

  2. Medial patellofemoral ligament reconstruction with a divergent patellar transverse 2-tunnel technique.

    PubMed

    Panni, Alfredo Schiavone; Alam, Mahbub; Cerciello, Simone; Vasso, Michele; Maffulli, Nicola

    2011-12-01

    The medial patellofemoral ligament (MPFL) is the primary passive restraint to lateral patellar dislocation and there is increasing awareness of its role in recurrent lateral patellar instability. This study was conducted to prospectively analyze the functional results of a modified MPFL reconstruction technique in recurrent patellar dislocation. Case series; Level of evidence, 4. Forty-eight patients (51 knees) with at least 3 episodes of lateral patellar dislocation who had been treated with a 6-month rehabilitation protocol were included in this study. All patients practiced sports regularly. Reconstruction was with a semitendinosus tendon using a divergent 2-tunnel technique. Outcome was evaluated with the Kujala, Larsen, modified Lysholm, and Fulkerson outcome scores. Patient satisfaction with range of motion, pain, and sporting activities was also assessed. Three patients were lost at the final follow-up, giving a follow-up rate of 94%. The mean follow-up was 33 months. There was no patella dislocation postoperatively. The mean Kujala score improved significantly (P < .01) from 56.7 ± 17.7 (2 × standard deviation) preoperatively to 86.8 ± 14.4 postoperatively. The mean Larsen score improved significantly (P < .01) from 12.4 ± 3.2 to 17.1 ± 2.7. The mean Fulkerson score improved significantly (P < .01) from 59.2 ± 21.8 to 90.1 ± 14. The mean modified Lysholm score improved significantly (P < .01) from 57.6 ± 19.6 to 88.1 ± 16.2. Sixty-four percent of patients returned to the same type of sport at the same level, 16% reduced the level or type of sport for reasons unrelated to the surgery, while 20% reduced the level of sport or changed it for reasons related to surgery. Eighty-seven percent were either satisfied or very satisfied with the pain relief achieved. The patellar tilt decreased significantly from a preoperative mean of 11.1° to 8.9° at the last follow-up (P = .02). The mean preoperative Insall-Salvati ratio of 1.1 decreased to 1.06, although

  3. Influence of Total Knee Arthroplasty on Patellar Kinematics and Patellofemoral Pressure.

    PubMed

    Tanikawa, Hidenori; Tada, Mitsunori; Harato, Kengo; Okuma, Kazunari; Nagura, Takeo

    2017-01-01

    Patellofemoral complications are one of the main problems after total knee arthroplasty (TKA). The design of the TKA component may affect the patellar biomechanics, which may be associated with this postoperative complication. The purpose of this study was to assess the influence of TKA and prosthesis designs on the patellar kinematics and patellofemoral pressure. Using fresh-frozen cadavers, we measured the patellofemoral pressure, patella offset, and patella tilt in the following 4 conditions: normal knee (patella replacement only), cruciate-retaining TKA, condylar-stabilizing TKA, and posterior-stabilized TKA. The patellofemoral pressure increased significantly after the cruciate-retaining TKA and condylar-stabilizing TKA compared with the normal knee. The patella offset in the normal knee decreased with increasing knee flexion angles, while the patella offset in the TKA knees did not change significantly through the full range of motion. The amount of lateral patella tilt in the normal knee was significantly larger than the TKA knees in the full range of motion. Although the femoral components are designed to reproduce an anatomical patellar tracking, the physiological patellar kinematics were not observed. Relatively high patellofemoral pressure and kinematic change after TKA may be associated with postoperative complications such as the anterior knee pain. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Patellar Sleeve Fracture With Ossification of the Patellar Tendon.

    PubMed

    Damrow, Derek S; Van Valin, Scott E

    2017-03-01

    Patellar sleeve fractures make up greater than 50% of all patellar fractures. They are essentially only seen in the pediatric population because of the thick periosteum and the distal patellar pole apophysis in this group. These fractures can lead to complications if not treated appropriately and in a timely fashion. Complications of missed or untreated patellar sleeve fractures include patella alta, anterior knee pain, and quadriceps atrophy. These can all result in severe limitations in activity. The authors describe a case of a 16-year-old boy who sustained a patellar sleeve fracture 3 years prior to presentation. On presentation, he had patella alta, diminished strength, 5° of extensor lag, and radiographs that revealed bone formation along the patellar tendon. Despite this, he was able to maintain a high level of activity. This case report explores how the patient could have maintained a high level of activity despite having a patellar sleeve fracture. Also, because of the delayed presentation, the patella was ossified and the quadriceps was retracted, which led to a novel approach to reconstructing his distal extensor mechanism. This approach included a V-Y advancement of the quadriceps tendon and patellar tendon reconstruction using the patient's hamstring tendon (semitendinosus). This technique, combined with physical therapy postoperatively, resulted in his return to varsity high school soccer. To the best of the authors' knowledge, this technique has not been reported for this rare condition. [Orthopedics. 2017; 40(2):e357-e359.]. Copyright 2016, SLACK Incorporated.

  5. Two Patients with Osteochondral Injury of the Weight-Bearing Portion of the Lateral Femoral Condyle Associated with Lateral Dislocation of the Patella

    PubMed Central

    Inoue, Hiroaki; Atsumi, Satoru; Ichimaru, Shohei; Fujiwara, Hiroyoshi; Kubo, Toshikazu

    2014-01-01

    Complications of patellar dislocation include osteochondral injury of the lateral femoral condyle and patella. Most cases of osteochondral injury occur in the anterior region, which is the non-weight-bearing portion of the lateral femoral condyle. We describe two patients with osteochondral injury of the weight-bearing surface of the lateral femoral condyle associated with lateral dislocation of the patella. The patients were 18- and 11-year-old females. Osteochondral injury occurred on the weight-bearing surface distal to the lateral femoral condyle. The presence of a free osteochondral fragment and osteochondral injury of the lateral femoral condyle was confirmed on MRI and reconstruction CT scan. Treatment consisted of osteochondral fragment fixation or microfracture, as well as patellar stabilization. Osteochondral injury was present in the weight-bearing portion of the lateral femoral condyle in both patients, suggesting that the injury was caused by friction between the patella and lateral femoral condyle when the patella was dislocated or reduced at about 90° flexion of the knee joint. These findings indicate that patellar dislocation may occur and osteochondral injury may extend to the weight-bearing portion of the femur even in deep flexion, when the patella is stabilized on the bones of the femoral groove. PMID:25506015

  6. Non-Traumatic Anterior Dislocation of a Total Knee Replacement Associated with Neurovascular Injury

    PubMed Central

    Aderinto, Joseph; Gross, Allan E; Rittenhouse, Bryan

    2009-01-01

    Prosthetic total knee replacements rarely dislocate. When dislocation does occur, it is usually in a posterior direction in association with a posterior stabilised, cruciate-sacrificing prosthesis. Neurovascular injury is unusual. In this report, we describe a case of anterior dislocation of a cruciate-retaining total knee replacement in a 67-year-old woman. The dislocation occurred in the absence of overt trauma and resulted in severe neurovascular injury. PMID:19686618

  7. The patellofemoral joint: from dysplasia to dislocation

    PubMed Central

    Zaffagnini, Stefano; Grassi, Alberto; Zocco, Gianluca; Rosa, Michele Attilo; Signorelli, Cecilia; Muccioli, Giulio Maria Marcheggiani

    2017-01-01

    Patellofemoral dysplasia is a major predisposing factor for instability of the patellofemoral joint. However, there is no consensus as to whether patellofemoral dysplasia is genetic in origin, caused by imbalanced forces producing maltracking and remodelling of the trochlea during infancy and growth, or due to other unknown and unexplored factors. The biomechanical effects of patellofemoral dysplasia on patellar stability and on surgical procedures have not been fully investigated. Also, different anatomical and demographic risk factors have been suggested, in an attempt to identify the recurrent dislocators. Therefore, a comprehensive evaluation of all the radiographic, MRI and CT parameters can help the clinician to assess patients with primary and recurrent patellar dislocation and guide management. Patellofemoral dysplasia still represents an extremely challenging condition to manage. Its controversial aetiology and its complex biomechanical behaviour continue to pose more questions than answers to the research community, which reflects the lack of universally accepted guidelines for the correct treatment. However, due to the complexity of this condition, an extremely personalised approach should be reserved for each patient, in considering and addressing the anatomical abnormalities responsible for the symptoms. Cite this article: EFORT Open Rev 2017;2. DOI: 10.1302/2058-5241.2.160081. Originally published online at www.efortopenreviews.org PMID:28630757

  8. Clinical Outcomes After Isolated Medial Patellofemoral Ligament Reconstruction for Patellar Instability Among Patients With Trochlear Dysplasia.

    PubMed

    Liu, Joseph N; Brady, Jacqueline M; Kalbian, Irene L; Strickland, Sabrina M; Ryan, Claire Berdelle; Nguyen, Joseph T; Shubin Stein, Beth E

    2018-03-01

    Medial patellofemoral ligament (MPFL) reconstruction has become one of the most common and widely used procedures to regain stability among patients with recurrent lateral patellar dislocation. While recent studies demonstrated low recurrence rates, improved patient-reported outcome measures, and a high rate of return to sports, limited literature explored its effectiveness as an isolated intervention in the context of trochlear dysplasia. To determine the efficacy of isolated MPFL reconstruction in treating patellar instability in the setting of trochlear dysplasia. Case series; Level of evidence, 4. This was a retrospective review of consecutive patients who underwent uni- or bilateral medial patellofemoral ligament reconstruction for patellofemoral instability with a minimum 2-year follow-up. No osteotomies were included. Pre- and postoperative assessment included ligamentous laxity, patellar crepitus, tilt, translation, apprehension, and radiographic features, including tibial tubercle-trochlear groove (TT-TG) distance, Dejour classification, and Caton-Deschamps index. A total of 121 MPFL reconstructions were included. Mean age at surgery was 23.8 years, and 4.4 dislocation events occurred before surgery. Mean follow-up was 44 months; 76% of patients were female. Mean preoperative TT-TG ratio was 13.5, and mean Caton-Deschamps ratio was 1.2; 92% of patients had Dejour B, C, or D trochlear dysplasia. Kujala score improved from 55.0 preoperatively to 90.0 ( P < .001). Almost all patients (94.5%) were able to return to sports at 1 year, with 74% returning to the same or higher level of play. Only 3 patients reported a postoperative dislocation or subluxation event. For patients without significantly elevated TT-TG distances or significant patella alta, isolated MPFL reconstruction provides a safe and effective treatment for patellofemoral instability, despite the presence of trochlear dysplasia. Most patients are able to return to sports by 1 year postoperatively

  9. [Intra-prosthetic dislocation of the Bousquet dual mobility socket].

    PubMed

    Lecuire, F; Benareau, I; Rubini, J; Basso, M

    2004-05-01

    The Bousquet system is a dual mobility head-polyethylene polyethylene-metal cup socket. The polyethylene insert retaining the femoral head moves in the noncemented metal cup, increasing both mobility and stability. Between 1989 and 1997, seven cases of intra-prosthetic dislocation (six patients) were observed. The femoral head escaped from the polyethylene insert due to wear. On the average, this complication occurred ten Years after implantation. Risk of dislocation was high in six of the seven hips. All patients had a large sized stem screwed into the femoral neck. There was a characteristic radiological aspect with loss of the concentric head metal cup configuration. The head was applied against the upper wall of the metal cup. Surgical replacement was undertaken early in six patients by simply changing the insert without modifying the other stable components. Outcome remained good at three to eight Years. One patient underwent late surgery. The insert and the cup were replaced with a classical implant. Functional outcome was good but recurrent dislocation occurred. At mid-term, intra-prosthetic dislocation of dual mobility sockets appears to be exceptional. Dislocation results from polyethylene wear leading to failure of the insert to retain the prosthetic head. Wear is favored by direct phenomena (direct contact between neck and insert which can occur early if there is a small difference in the head and neck diameters) or indirect phenomena (factors limiting polyethylene metal-cup mobility). Surgical treatment is necessary. If undertaken early, replacement with a modular head and insert can be sufficient if the prosthesis has not loosened but the metal cup may have to be replaced in the event of metal-metal contact between the head and the cup. Prosthesis loosening, wear of the metal cup, or an identified cause of dislocation imply replacing the failing implants. Implantation of the dual mobility system is particularly interesting for patients with a high risk

  10. Proximo-distal patellar position in three small dog breeds with medial patellar luxation.

    PubMed

    Wangdee, C; Theyse, L F H; Hazewinkel, H A W

    2015-01-01

    Medial patellar luxation is thought to be associated with a high proximal position of the patella in the trochlear groove. To determine whether the ratio of patellar ligament length and patellar length (L:P) is influenced by the stifle angle (75°, 96°, 113°, 130°, and 148°) in small dog breeds and to compare the L:P ratio in dogs of three small dog breeds with and without medial patellar luxation. A mediolateral radiograph of the stifle joint was used to measure the L:P ratio in the stifle joints of dogs of three small breeds with and without medial patellar luxation. The L:P ratio was evaluated at five stifle angles (75°, 96°, 113°, 130°, and 148°) in 14 cadavers (26 stifle joints) of small dog breeds in order to identify the best stifle angle to measure the L:P ratio. Then the mean ± SD L:P ratio was calculated for normal stifles and stifles with medial patellar luxation grades 1, 2, and 3 in 194 Pomeranians, 74 Chihuahuas, and 41 Toy or Standard Poodles. The L:P ratio was the same for all five stifle angles in the cadavers (p = 0.195). It was also not significantly different in the three breeds (p = 0.135), in normal and medial patellar luxation-affected stifles overall (p = 0.354), and in normal and medial patellar luxation-affected joints within each breed (p = 0.19). We conclude that a proximo-distal patellar position is not associated with medial patellar luxation in Pomeranians, Chihuahuas, and Toy or Standard Poodles. Thus a longer patellar ligament length does not play a role in the pathophysiology of medial patellar luxation in these small dog breeds.

  11. Adolescent patellar instability: current concepts review.

    PubMed

    Clark, D; Metcalfe, A; Wogan, C; Mandalia, V; Eldridge, J

    2017-02-01

    Patellar instability most frequently presents during adolescence. Congenital and infantile dislocation of the patella is a distinct entity from adolescent instability and measurable abnormalities may be present at birth. In the normal patellofemoral joint an increase in quadriceps angle and patellar height are matched by an increase in trochlear depth as the joint matures. Adolescent instability may herald a lifelong condition leading to chronic disability and arthritis. Restoring normal anatomy by trochleoplasty, tibial tubercle transfer or medial patellofemoral ligament (MPFL) reconstruction in the young adult prevents further instability. Although these techniques are proven in the young adult, they may cause growth arrest and deformity where the physis is open. A vigorous non-operative strategy may permit delay of surgery until growth is complete. Where non-operative treatment has failed a modified MPFL reconstruction may be performed to maintain stability until physeal closure permits anatomical reconstruction. If significant growth remains an extraosseous reconstruction of the MPFL may impart the lowest risk to the physis. If minor growth remains image intensifier guided placement of femoral intraosseous fixation may impart a small, but acceptable, risk to the physis. This paper presents and discusses the literature relating to adolescent instability and provides a framework for management of these patients. Cite this article: Bone Joint J 2017;99-B:159-70. ©2017 The British Editorial Society of Bone & Joint Surgery.

  12. Radial head reconstruction in elbow fracture-dislocation: monopolar or bipolar prosthesis?

    PubMed

    Hartzler, Robert U; Morrey, Bernard F; Steinmann, Scott P; Llusa-Perez, Manuel; Sanchez-Sotelo, Joaquin

    2014-07-01

    Monopolar and bipolar radial head prosthetic arthroplasties have been used successfully to treat elbow fracture-dislocation with unsalvageable radial head fractures. The relative stability of these two designs in different clinical situations is a topic of ongoing investigation. We tested the effects of monopolar and bipolar fixed-neck prosthetic radial head implants on improvement in elbow coronal and axial plane laxity in a terrible triad biomechanical model that accounted for lateral collateral ligament integrity and the presence of a transverse coronoid fracture. Kinematic data were collected on six fresh-frozen cadaveric upper extremities tested with passive motion throughout the flexion arc. Varus and valgus gravity stress were applied with the wrist in neutral position. A lateral collateral ligament reconstruction was simulated. We assessed instability after radial head resection and reconstruction with either a monopolar or bipolar implant in the presence of a transversely fractured (Regan and Morrey Type 2) or fixed coronoid process. With collateral ligament integrity, no difference was detected, with the numbers available, in valgus laxity between implants under valgus stress (p = 1.0). Laxity improvement with each prosthesis was higher when the coronoid was fractured (mean ± SD: monopolar: 7.4° ± 1.6°, p < 0.001; bipolar: 6.4° ± 1.6°, p = 0.003) than when it was fixed (monopolar: 4.0° ± 1.6°, p = 0.02; bipolar: 4.2° ± 1.6°, p = 0.01). With the numbers available, there was no difference in external rotation laxity between implants under valgus stress (p = 1.0). The greatest stabilizing effect of the prostheses occurred when the coronoid was fractured (monopolar: 3.3° ± 1.2°, p = 0.15; bipolar: 3.3° ± 1.2°, p = 0.17). Radial head arthroplasty offered no substantial stability under varus stress for varus or internal rotation laxity. In our terrible triad cadaveric model, coronoid fixation was effective in

  13. Combined distal femoral osteotomy (DFO) in genu valgum leads to reliable patellar stabilization and an improvement in knee function.

    PubMed

    Frings, Jannik; Krause, Matthias; Akoto, Ralph; Wohlmuth, Peter; Frosch, Karl-Heinz

    2018-06-04

    Valgus deformities of the lower extremity influence patellofemoral joint kinematics. However, studies examining the clinical outcome after treatment of patellar instability and maltracking due to valgus deformity are rare in recent literature. This study's purpose is to analyze the clinical results after combined distal femoral osteotomy (DFO) for treatment of patellar instability. From 2010 to 2016, 406 cases of patellofemoral instability and maltracking were treated. Twenty cases of recurring (≥ 2) patellar dislocations with genu valgum and unsuccessful conservative treatment were included in the study. A radiological analysis was performed, and anteroposterior (AP), lateral and long leg standing radiographs were analyzed, and the leg axis was pre- and postoperatively measured. At least 12 months postoperatively, the clinical leg axis, range of motion (ROM), apprehension sign, Zohlen sign, and J-sign were physically examined. Pain level and knee function were objectified on a visual analogue scale (VAS). The Lysholm, Kujala, and Tegner scores, re-dislocation rate, and patient satisfaction were also examined. 20 combined DFOs on 18 patients with a median age of 23 years (15-55 years) were performed. The preoperative mechanical leg axis was 6.5° ± 2.0° valgus, and the mean tibial tuberosity to trochlear groove (TT-TG) distance was 19.1 ± 4.8 mm. All patients reported multiple dislocations. Intraoperatively, 71% presented III°-IV° cartilage lesions, located retropatellarly in 87% and correlating negatively with the postoperative Lysholm score (r = - 0.462, p = 0.040). The leg axis was corrected by 7.1° ± 2.6°, and in 17 cases, the tibial tubercle was additionally medialized by 10 ± 3.1 mm. All patellae were re-stabilized with medial patellofemoral ligament reconstruction. After a median period of 16 (12-64) months, the pain level decreased from 8.0 ± 1.4 to 2.3 ± 2.1 (VAS p ≤ 0.001) and knee function

  14. Excessive lateral patellar translation on axial computed tomography indicates positive patellar J sign.

    PubMed

    Xue, Zhe; Song, Guan-Yang; Liu, Xin; Zhang, Hui; Wu, Guan; Qian, Yi; Feng, Hua

    2018-03-20

    The purpose of the study was to quantify the patellar J sign using traditional computed tomography (CT) scans. Fifty-three patients (fifty-three knees) who suffered from recurrent patellar instability were included and analyzed. The patellar J sign was evaluated pre-operatively during active knee flexion and extension. It was defined as positive when there was obvious lateral patellar translation, and negative when there was not. The CT scans were performed in all patients with full knee extension; and the parameters including bisect offset index (BOI), patellar-trochlear-groove (PTG) distance, and patellar lateral tilt angle (PLTA) were measured on the axial slices. All the three parameters were compared between the J sign-positive group (study group) and the J sign-negative group (control group). In addition, the optimal thresholds of the three CT scan parameters for predicting the positive patellar J sign were determined with receiver operating characteristic (ROC) curves, and the diagnostic values were assessed by the area under the curve (AUC). Among the fifty-three patients (fifty-three knees), thirty-seven (70%) showed obvious lateral patellar translation, which were defined as positive J sign (study group), and the remaining sixteen (30%) who showed no lateral translation were defined as negative J sign (control group). The mean values of the three CT parameters in the study group were all significantly larger compared to the control group, including BOI (121 ± 28% vs 88 ± 12%, P = 0.038), PTG distance (5.2 ± 6.6 mm vs - 4.4 ± 5.2 mm, P < 0.05), and PLTA (34.9 ± 10.5° vs 25.7 ± 3.4°, P = 0.001). Furthermore, the evaluation of ROC analysis showed that the AUC of BOI was the largest (AUC = 0.906) among the three parameters, and the optimal threshold of BOI to predict the positive patellar J sign was 97.5% (Sensitivity = 83.3%, Specificity = 87.5%). In this study, the prevalence of positive patellar J

  15. Bilateral Patellar Tendon Rupture

    DTIC Science & Technology

    2009-07-01

    Bilateral patellar tendon rupture Military Medicine Radiology Corner, Volume 173, July, 2009...Radiology Corner Bilateral patellar tendon rupture (#37) Guarantor: 2dLt Ramon A. Riojas, USAF, MSC1 Contributors: 2dLt Ramon A. Riojas...with the abbreviated answer in the July 2009 issue. 1 The authors present a case of bilateral patellar tendon rupture in an active duty male exiting

  16. Titanium clip ball joint: a partial ossicular reconstruction prosthesis.

    PubMed

    Beutner, Dirk; Luers, Jan Christoffer; Bornitz, Matthias; Zahnert, Thomas; Huttenbrink, Karl-Bernd

    2011-06-01

    To describe a new titanium clip prosthesis for partial ossicular reconstruction with a micro ball joint in the headplate for compensation of tympanic membrane displacements. Laboratory experiments followed by 18 consecutive patients. A micro ball joint was implemented into a headplate of titanium middle ear prosthesis. First, the new prosthesis was tested in the laboratory in temporal bone experiments. Second, the new prosthesis was clinically installed in 18 patients. Results of laser Doppler vibrometry and force measurements in the laboratory experiments, analysis of a questionnaire, and preoperative and postoperative pure tone audiometry. The frictional resistance in the joint was measured to be 12 mN that should allow for adequate mobility under physiologic conditions. The effective sound transmission of the prosthesis was demonstrated by laser Doppler vibrometry. Intraoperatively, the installation of the prosthesis was always straightforward with headplate prosthesis shaft angles between 60 and 90 degrees. Postoperatively, pure tone audiometry revealed satisfying hearing results with a remaining average air-bone gap of 18.2 dB over the frequencies 500, 1,000, 2,000, and 3,000 Hz. No signs of prosthesis dislocation were discovered within the follow-up period of approximately 6 months. The experimental data show that the new modified prosthesis headplate fulfills the requirements necessary for sound transmission. The joint allows the plate to follow movements of the tympanic membrane. This characteristic in conjunction with the proven clip design ensure for optimal prosthesis placement and effectiveness.

  17. Patellar metastasis from primary tumor

    PubMed Central

    Li, Gang; Shan, Changxing; Sun, Ran; Liu, Song; Chen, Song; Song, Mingzhi; Lu, Ming

    2018-01-01

    Although bone tumors are frequently located in the knee area, primary tumors of the patella are rare and patellar metastases are even rarer. Knee pain is the most common complaint of patients with patellar metastases. Owing to the low incidence of patellar metastases, misdiagnosis is not unusual. The present review analyzes ~44 cases of patellar metastases originating from distinct primary sites. Reports of malignant tumors of the lung and kidney metastasizing to the patella were more common than those of other patellar metastases. Relative incidence, symptomatology, imaging features, histopathology and treatment options for these patellar metastatic lesions are described respectively along with a review of the literature. Despite numerous experiments demonstrating the reasons for implantation of tumor in patella, the answer to this question has not yet been revealed. In the light of the increasing attention on the diagnosis and the treatment of these lesions, the availability of the integrated information regarding metastases in the patella becomes more relevant. PMID:29434829

  18. Does the grading of chondromalacia patellae influence anterior knee pain following total knee arthroplasty without patellar resurfacing?

    PubMed

    Zha, Guo-Chun; Feng, Shuo; Chen, Xiang-Yang; Guo, Kai-Jin

    2018-03-01

    The influence of chondromalacia patellae (CMP) on post-operative anterior knee pain (AKP) following total knee arthroplasty (TKA) remains controversial, and few studies have focused on the relationship between them. The purpose of this study was to determine whether different CMP grades affect the incidence of AKP after TKA without patellar resurfacing. We performed a retrospective analysis of prospectively collected data on 290 TKAs with the use of the low contact stress mobile-bearing prosthesis, without patellar resurfacing in 290 patients from February 2009 to January 2013. Patients were assessed by the Outerbridge classification for CMP, visual analog scale for AKP, the Knee Society clinical scoring system of knee score (KS), function score (FS), the patellar score (PS) for clinical function, and patients' satisfaction. The intra-operative grading of CMP: grade I in 30 patients, grade II in 68 patients, grade III in 97 patients, and grade IV in 95 patients. The incidence of AKP at 36-month follow-up was 10.3% (30/290). No statistical difference was detected among the different CMP grades in terms of the incidence of AKP (p = 0.995), patients' satisfaction (p = 0.832), KS (p = 0.228), FS (p = 0.713), and PS (p = 0.119) at 36-month follow-up. The findings may suggest no relevant influence of CMP grading on the incidence of AKP after TKA without patellar resurfacing.

  19. [Tracheobronchial prosthesis in Mounier-Kuhn syndrome: New perspectives].

    PubMed

    Sauvage, M; Tiffet, O; Vergnon, J-M

    2015-05-01

    Mounier-Kuhn syndrome or tracheobronchomegaly is a rare congenital condition, the management of which is complex. We report the case of a patient who was treated with interventional endoscopy. We describe the case of a 74-year-old man with a diagnosis of tracheobronchomegaly who was admitted in 2003 with a background of deteriorating respiratory status and the occurrence of postural syncope. He initially received a tracheobronchial silicone Y prosthesis, extended with metal prostheses at the tracheal and bronchial level. This arrangement remained stable until 2011. He then began to develop episodes of asphyxia related to posterior dislocation of the tracheobronchial prosthesis, after breakage of the metallic mesh tracheal prosthesis. A new tracheobronchial prosthesis Y was then placed, custom-made from a 3D model of the airways. This was clinically and functionally effective. This case describes the management of a patient with Mounier-Kuhn syndrome by interventional bronchoscopy, with the adaptation of prosthetic materials, on an individual basis, to the anatomy of the patient's airway. Copyright © 2015 SPLF. Published by Elsevier Masson SAS. All rights reserved.

  20. Verge of Collapse: The Pros/thesis of Art Research

    ERIC Educational Resources Information Center

    Garoian, Charles R.

    2008-01-01

    This article explores "prosthesis" as a metaphor of embodiment in art-based research to challenge the utopian myth of wholeness and normality in art and the human body. Bearing in mind the correspondences between amputated bodies and the cultural dislocations of art, I propose "prosthetic epistemology" and "prosthetic ontology" as embodied knowing…

  1. 21 CFR 888.3480 - Knee joint femorotibial metallic constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femorotibial metallic constrained... Knee joint femorotibial metallic constrained cemented prosthesis. (a) Identification. A knee joint... knee joint. The device prevents dislocation in more than one anatomic plane and has components that are...

  2. Axial linear patellar displacement: a new measurement of patellofemoral congruence.

    PubMed

    Urch, Scott E; Tritle, Benjamin A; Shelbourne, K Donald; Gray, Tinker

    2009-05-01

    The tools for measuring the congruence angle with digital radiography software can be difficult to use; therefore, the authors sought to develop a new, easy, and reliable method for measuring patellofemoral congruence. The abstract goes here and covers two columns. The abstract goes The linear displacement measurement will correlate well with the congruence angle measurement. here and covers two columns. Cohort study (diagnosis); Level of evidence, 2. On Merchant view radiographs obtained digitally, the authors measured the congruence angle and a new linear displacement measurement on preoperative and postoperative radiographs of 31 patients who suffered unilateral patellar dislocations and 100 uninjured subjects. The linear displacement measurement was obtained by drawing a reference line across the medial and lateral trochlear facets. Perpendicular lines were drawn from the depth of the sulcus through the reference line and from the apex of the posterior tip of the patella through the reference line. The distance between the perpendicular lines was the linear displacement measurement. The measurements were obtained twice at different sittings. The observer was blinded as to the previous measurements to establish reliability. Measurements were compared to determine whether the linear displacement measurement correlated with congruence angle. Intraobserver reliability was above r(2) = .90 for all measurements. In patients with patellar dislocations, the mean congruence angle preoperatively was 33.5 degrees , compared with 12.1 mm for linear displacement (r(2) = .92). The mean congruence angle postoperatively was 11.2 degrees, compared with 4.0 mm for linear displacement (r(2) = .89). For normal subjects, the mean congruence angle was -3 degrees and the mean linear displacement was 0.2 mm. The linear displacement measurement was found to correlate with congruence angle measurements and may be an easy and useful tool for clinicians to evaluate patellofemoral

  3. Patellar Tendinopathy

    PubMed Central

    Schwartz, Aaron; Watson, Jonathan N.; Hutchinson, Mark R.

    2015-01-01

    Context: Patellar tendinopathy is a common condition. There are a wide variety of treatment options available, the majority of which are nonoperative. No consensus exists on the optimal method of treatment. Evidence Acquisition: PubMed spanning 1962-2014. Study Design: Clinical review. Level of Evidence: Level 4. Results: The majority of cases resolve with nonoperative therapy: rest, physical therapy with eccentric exercises, cryotherapy, anti-inflammatories, corticosteroid injections, extracorporeal shockwave therapy, glyceryl trinitrate, platelet-rich plasma injections, and ultrasound-guided sclerosis. Refractory cases may require either open or arthroscopic debridement of the patellar tendon. Corticosteroid injections provide short-term pain relief but increase risk of tendon rupture. Anti-inflammatories and injectable agents have shown mixed results. Surgical treatment is effective in many refractory cases unresponsive to nonoperative modalities. Conclusion: Physical therapy with an eccentric exercise program is the mainstay of treatment for patellar tendinopathy. Platelet-rich plasma has demonstrated mixed results; evidence-based recommendations on its efficacy cannot be made. In the event that nonoperative treatment fails, surgical intervention has produced good to excellent outcomes in the majority of patients. PMID:26502416

  4. The Effect of Patellar Thickness on Intraoperative Knee Flexion and Patellar Tracking in Patients With Arthrofibrosis Undergoing Total Knee Arthroplasty.

    PubMed

    Kim, Abraham D; Shah, Vivek M; Scott, Richard D

    2016-05-01

    We evaluated the intraoperative effect of patellar thickness on intraoperative passive knee flexion and patellar tracking during total knee arthroplasty (TKA) in patients with preoperative arthrofibrosis and compared them to patients with normal preoperative range of motion (ROM) documented in a prior study. Routine posterior cruciate ligament-retaining TKA was performed in a total of 34 knees, 23 with normal ROM and 11 with arthrofibrosis, defined as ≤100° of passive knee flexion against gravity under anesthesia. Once clinical balance and congruent patellar tracking were established, custom trial patellar components thicker than the standard trial by 2-mm increments (2-8 mm) were sequentially placed and trialed. Passive flexion against gravity was recorded using digital photograph goniometry. Gross mechanics of patellofemoral tracking were visually assessed. On average, passive knee flexion decreased 2° for every 2-mm increment of patellar thickness (P < .0001), which was similar to patients with normal preoperative ROM. In addition, increased patellar thickness had no gross effect on patellar subluxation and tilt in patients with arthrofibrosis as well as those with normal ROM. Patellar thickness had a modest effect on intraoperative passive flexion and no effect on patellar tracking in patients with arthrofibrosis undergoing TKA. There was no marked difference in intraoperative flexion and patellar tracking between patients with arthrofibrosis and patients with normal preoperative ROM. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. [Treatment of conmminuted patellar fractures with internal Ni-Ti patellar concentrator and tension bind wire fixation].

    PubMed

    Tan, Hong-lie; Qian, Chen; Zhao, Jin-kun; Shi, Yan; Zhou, Qi

    2009-02-01

    To study the clinical efficacy of the treatment of comminuted patellar fractures with internal NiTi-Patellar concentrator and tension bind wire fixation. From March 2004 to June 2007, 38 cases of fresh comminuted patellar fractures were treated with internal NiTi-Patellar concentrator and tension bind wire fixation. There were 25 males and 13 females,ranging from 21 to 64 years (mean 42.5 years). All were comminuted fractures with displacement, 16 cases were 3 fragments, 14 cases were 4 fragments, 8 cases were 5 fragments. There were other fractures in 8 cases. During followed-up, knee function and complications were evaluated. All patients were followed up for 8 to 24 months (mean 15 months) and obtained complete bone union. No case of implant was loosening and fragment displacement, traumatic arthritis occured in 2 cases. Under Lysholm & Gillquist score, the results were excellent in 17 cases, good in 19, fair in 2. Internal Ni-Ti-Patellar concentrator and tension bind wire fixation is one of the ideal methods for the treatment of comminuted patellar fracture, which could provide satisfied reduction, reliable fixation and good functional recovery.

  6. Neglected bilateral congenital dislocation of the patella.

    PubMed

    Tokgöz, Mehmet Ali; Çavuşoğlu, Ali Turgay; Ayanoğlu, Tacettin; Elma, Tarık; Vural, Abdurrahman

    2017-08-01

    Congenital dislocation of the patella is a disorder that presents with dysfunction in extensor mechanism. Although congenital dislocation of the patella mostly occurs in children with genetic disorders, it may also occur in totally healthy children, despite rarely. In this article, we report a 16-year-old male patient who referred to our clinic with complaints of gait disturbance, frequent falls, and muscular weakness in lower extremity. The patient had no complaints during walking, but had difficulty in running and walking up and down the stairs. It was observed that the range of motion of the knee joint was completely painless and the quadriceps muscle strength was evaluated as 3/5. An evaluation of computed tomography and magnetic resonance imaging results showed that the patella was dislocated. It became clear with magnetic resonance imaging that extensor mechanism was continuous but patellar tendon was not attached to its anatomical position. Surgical treatment was not planned because the patient did not describe any pain complaint and there was no limitation of joint movement, he could walk without support and without device and also refused to be operated. The choice of treatment should be based on the patient's preference, and pain and functional status.

  7. Late dislocation of rotating platform in New Jersey Low-Contact Stress knee prosthesis.

    PubMed

    Huang, Chun-Hsiung; Ma, Hon-Ming; Liau, Jiann-Jong; Ho, Fang-Yuan; Cheng, Cheng-Kung

    2002-12-01

    Five patients with late rotational dislocation of the rotating platform bearing in the New Jersey Low-Contact Stress total knee arthroplasty are reported. The prostheses had functioned well for 8 to 12 years before failure. Preoperative radiographs showed asymmetric femorotibial joint spaces. Entrapment of the dislocated bearing in three patients and spontaneous reduction of the dislocated bearing in another two patients were seen at revision. Femorotibial ligamentous instability was found after reduction. The retrieved polyethylene bearings showed advanced wear and cold flow deformities and the thickness was reduced. The revision arthroplasty was accomplished by replacement with a thicker bearing element. Progressive femorotibial ligament laxity and reduction of the thickness of polyethylene with wearing break down the originally well-balanced soft tissue tension of the knee. The rotational degree of the rotating platform bearing is unrestricted, which may result in late dislocation. Polyethylene wear is unavoidable in knee prostheses using metal contact with polyethylene even with a mobile-bearing design. Efforts to reduce polyethylene wear are mandatory.

  8. Bilateral Patellar Tendon Rupture.

    PubMed

    Kamienski, Mary

    The knee is the most complex and largest joint in the body. Injuries to any part of this joint affect the entire body. There are multiple injuries that can occur to the knee, with the most common being ligament and meniscus tears. A not-so-common injury to the knee is a patellar tendon rupture. A bilateral patellar tendon rupture is extremely rare. A case study of a 43-year-old man who sustained a bilateral patellar tendon rupture while playing softball is used to present this devastating injury. This discussion includes the incidence and diagnosis of the tear, surgical repair, as well as a description of the comprehensive rehabilitation process necessary to allow the patient to return to normal physical activity. Risks and complications of this surgery and the expected outcomes are also presented.

  9. [Dislocated fracture of the lesser trochanter with malrotation of the stem after robot assisted implantation of a cementless hip prosthesis: a casuistic report].

    PubMed

    Prymka, M; Hassenpflug, J

    2003-08-01

    This paper presents the case of a 63 year old female with a severe coxarthrosis. She got a robot assited implantation of a cementless hip prosthesis (Osteolock, Stryker-Howmedica, Mühlheim). As operation robot the CASPAR-System (Orto-Maquet, Rastatt) was used. Initially, the clinical progress of the patient was fine. She was nearly painfree within 14 days and showed an acceptable range of motion in the operated joint (flexion/ extension 90 degrees /05 degrees /00 degrees ). She was mobilized with crutches and 15 kg weight bearing at the operated leg. 3 weeks postoperative the patient complaint about increasing pain without trauma or intensification of the weight bearing. X-rays showed not only a dislocated fracture of the lesser trochanter, but also a sinking combined with a malrotation of the stem. A revision operation was necessary,where we implanted a cemented stem. Now clinical progress was completely satisfying.

  10. Effect of patellar strap and sports tape on pain in patellar tendinopathy: A randomized controlled trial.

    PubMed

    de Vries, A; Zwerver, J; Diercks, R; Tak, I; van Berkel, S; van Cingel, R; van der Worp, H; van den Akker-Scheek, I

    2016-10-01

    Numerous athletes with patellar tendinopathy (PT) use a patellar strap or sports tape during sports. This study's aim was to investigate the short-term effect of these orthoses on patellar tendon pain. Participants performed the single-leg decline squat, vertical jump test, and triple-hop test under four different conditions (patellar strap, sports tape, placebo, and control). Subsequently, participants practiced sports as usual for 2 weeks; during 1 week, they were assigned to one of the four conditions. Pain was measured with the visual analog scale (VAS). In total, 97 athletes with PT [61% male, age 27.0 (SD8.1), VISA-P 58.5 (SD12.7)] were analyzed. On the single-leg decline squat, the VAS pain score reduced significantly in the patellar strap (14 mm, P = 0.04) and the sports tape condition (13 mm, P = 0.04), compared with control, but not placebo. A significant decrease in VAS pain during sports was found in the sports tape (7 mm, P = 0.04) and placebo group (6 mm, P = 0.04). The VAS pain score two hours after sports decreased significantly in the patellar strap, sports tape and placebo group (8-mm, P < 0.001, 10 mm, P = 0.001 and 7 mm, P = 0.03, respectively). This study's findings indicate that an orthosis (including placebo tape) during sports can reduce pain in PT patients in the short term. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Landing strategies of athletes with an asymptomatic patellar tendon abnormality.

    PubMed

    Edwards, Suzi; Steele, Julie R; McGhee, Deirdre E; Beattie, Sue; Purdam, Craig; Cook, Jill L

    2010-11-01

    Risk factors associated with a clinical presentation of patellar tendinopathy are patellar tendon ultrasonographic abnormality (PTA) and excessive loading. It remains unknown whether characteristics of an athlete's landing technique contribute to this excessive patellar tendon loading. This study investigated whether asymptomatic athletes with and without PTA had different landing strategies and hypothesized that asymptomatic athletes with a PTA would create higher patellar tendon loading and a different lower-limb landing strategy compared with athletes with normal patellar tendons. Seven athletes with no previous history or clinical signs of patellar tendon injury with a PTA were matched to athletes with normal patellar tendons (controls). Participants performed five successful trials of a stop-jump task, which involved a simultaneous two-foot horizontal and then vertical landing. During each trial, the participants' ground reaction forces and lower-limb electromyographic data were recorded, the three-dimensional kinematics measured, and the peak patellar tendon force calculated by dividing the net knee joint moment by the patellar tendon moment arm. Significant between-group differences in landing technique were mostly observed during the horizontal landing phase. Participants with a PTA created similar patellar tendon loading to the controls, but with altered sequencing, by landing with significantly greater knee flexion and extending their hips while the controls flexed their hips as they landed, reflecting a different muscle recruitment order compared with the PTA group. The crucial part in the development of PTA and, in turn, patellar tendinopathy may not be the magnitude of the patellar tendon load but rather the loading patterns. This research provides clinicians with important landing assessment criteria against which to identify athletes at risk of developing patellar tendinopathy.

  12. Patellar Instability Management: A Survey of the International Patellofemoral Study Group.

    PubMed

    Liu, Joseph N; Steinhaus, Michael E; Kalbian, Irene L; Post, William R; Green, Daniel W; Strickland, Sabrina M; Shubin Stein, Beth E

    2017-10-01

    Although patellofemoral instability is among the most prevalent knee disorders, the management of patients with this condition is complex and remains variable, given the lack of long-term, high-level clinical outcome studies to compare various operative and nonoperative modalities. To discover a consensus within treatment controversies in patellofemoral instability among experienced knee surgeons with a specific interest in the patellofemoral joint. Expert opinion; Level of evidence, 5. A 3-step modified Delphi technique was used to establish a consensus. A 34-question, case-based online survey regarding patellofemoral instability was distributed to all active members of the International Patellofemoral Study Group. Consensus statements were generated if at least 66% of the respondents agreed and then redistributed to the same panel. Modifications to the consensus statements were made based on the iterative feedback process until no discordance was encountered in the third stage. Eight consensus statements were achieved. Nonoperative management is the current standard of care for a first-time dislocation in the absence of an osteochondral fragment or loose body requiring excision (100% agreement). In patients with a first-time dislocation with an operative osteochondral fracture requiring excision or repair, patellar instability should be addressed concurrently (89% agreement). Recurrent instability should be treated surgically, with most surgeons favoring medial reconstruction (77%-86% agreement). While there is general agreement that bony procedures should be performed to correct underlying bony deformities, there is no consensus regarding the most appropriate type of procedure performed. Lateral release should not be performed in isolation for the treatment of patellar instability (89% agreement). Despite the consensus generated in this study, our current understanding remains limited by a lack of high-level evidence as well as the numerous complex variables

  13. The Effect of Electrocautery around the Patellar Rim in Patellar Non-Resurfacing Total Knee Arthroplasty

    PubMed Central

    Yim, Soo Jae; Jang, Mun Suk; Kim, Wook Joong; Kang, Hee Kyung

    2012-01-01

    Purpose The purpose of this study was to evaluate the clinical effect of electrocautery on the reduction of pain in patellar non-resurfacing bilateral total knee arthroplasty. Materials and Methods A total of 50 patients were enrolled into this study; all patients had undergone bilateral patellar non-resurfacing total knee arthoplasty at our hospital, between January 2007 to December 2008. The minimum follow-up period was 1 year. The electrocautery of the patellar rim was performed randomly on one side only. The clinical results were evaluated between the electrocautery group and the non-electrocautery group based on measures of anterior knee pain, range of motion, American Knee Society clinical rating score, Feller knee score, Western Ontario and McMaster Universities score, and radiographic analysis. Results There were statistically significant differences between preoperative and postoperative status for all parameters. There were no statistically significant differences noted between the electrocautery group and the non electrocautery group for all parameters. Conclusions Electrocautery of patellar rim is thought to be less effective in reducing anterior knee pain. PMID:22708111

  14. Eliminating impingement optimizes patellar biomechanics in high knee flexion.

    PubMed

    Tang, Qi-heng; Zhou, Yi-xin; Tang, Jing; Shao, Hong-yi; Wang, Guang-zhi

    2010-08-01

    We investigated the impact of eliminating the impingement between extensor mechanism and tibial insert on patellar tracking and patellar ligament tension in high knee flexion. Six cadaveric specimens were tested on an Oxford-type testing rig. The Genesis II knee system was implanted into each specimen knee with the traditional tibial insert and high-flex insert successively. Compared to traditional insert, the high-flex insert was characterized with a chambered anterior post and a chambered anterior lip which eliminates patella-post and patellar ligament-anterior lip impingements. The patella was tracked with an NDI Optotrak Certus system. The patellar ligament tension was measured using a NKB S-type tension transducer. There was a decrease of resultant patellar translation relative to the femur with statistically significant (P<0.05) at 90 degrees to 150 degrees of knee flexion and a decrease of patellar ligament tension with statistical significance (P<0.05) at 100 degrees, 120 degrees, 130 degrees, and 140 degrees of flexion using high-flex insert compared to traditional insert. Eliminating the impingement between extensor mechanism and implant in high knee flexion altered patellar tracking and reduced patellar ligament tension, which would facilitate high knee flexion.

  15. A new malleostapedotomy prosthesis. Experimental analysis by laser doppler vibrometer in fresh cadaver temporal bones.

    PubMed

    Vallejo, Luis A; Manzano, María T; Hidalgo, Antonio; Hernández, Alberto; Sabas, Juan; Lara, Hugo; Gil-Carcedo, Elisa; Herrero, David

    One of the problems with total ossicular replacement prostheses is their stability. Prosthesis dislocations and extrusions are common in middle ear surgery. This is due to variations in endo-tympanic pressure as well as design defects. The design of this new prosthesis reduces this problem by being joined directly to the malleus handle. The aim of this study is to confirm adequate acoustic-mechanical behaviour in fresh cadaver middle ear of a new total ossicular replacement prosthesis, designed using the finite elements method. Using the doppler vibrometer laser, we analysed the acoustic-mechanical behaviour of a new total ossicular replacement prosthesis in the human middle ear using 10 temporal bones from fresh cadavers. The transfer function of the ears in which we implanted the new prosthesis was superimposed over the non-manipulated ear. This suggests optimum acoustic-mechanical behaviour. The titanium prosthesis analysed in this study demonstrated optimum acoustic-mechanical behaviour. Together with its ease of implantation and post-surgical stability, these factors make it a prosthesis to be kept in mind in ossicular reconstruction. Copyright © 2016 Elsevier España, S.L.U. and Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. All rights reserved.

  16. [Prevention and repair of patellar ligament injury in total knee arthroplasty].

    PubMed

    Bian, Yanyan; Weng, Xisheng

    2013-09-01

    To review the progress in the prevention and repair of patellar ligament injury in total knee Recent literature about the prevention and repair of patellar ligament injury in total knee arthroplasty arthroplasty. was reviewed and analyzed. Increased exposure can prevent the patellar ligament injury, and treatments of acute patellar ligament rupture can be obtained by simple repair, reconstruction with allograft materials or artificial materials, and auxiliary strengthening. Patellar ligament injury in total knee arthroplasty should not be ignored. Active prevention and repair of patellar ligament injury can obtain better function of knee joint.

  17. The Analysis of Risk Factors in No Thumb Test in Total Knee Arthroplasty

    PubMed Central

    Kim, Jee Hyoung; Ko, Dong Oh; Yoo, Chang Wook; Chun, Tae Hwan; Lee, Jung Soo

    2011-01-01

    Background We would like to analyze the risk factors of no thumb test among knee alignment tests during total knee arthroplasty surgery. Methods The 156 cases of total knee arthroplasty by an operator from October 2009 to April 2010 were analyzed according to preoperative indicators including body weight, height, degree of varus deformity, and patella subluxation and surgical indicators such as pre-osteotomy patella thickness, degree of patella degeneration, no thumb test which was evaluated after medial prepatella incision and before bone resection (1st test), no thumb test which was evaluated with corrective valgus stress (2nd test, J test), and the kind of prosthesis. We comparatively analyzed indicators affecting no thumb test (3rd test). Results There was no relation between age, sex, and body weight and no thumb test (3rd test). Patellar sulcus angle (p = 0.795), patellar congruence angle (p = 0.276) and preoperative mechanical axis showed no relationship. The 1st no thumb test (p = 0.007) and 2nd test (p = 0.002) showed significant relation with the 3rd no thumb test. Among surgical indicators, pre-osteotomy patella thickness (p = 0.275) and degeneration of patella (p = 0.320) were not relevant but post-osteotomy patellar thickness (p = 0.002) was relevant to no thumb test (3rd test). According to prosthesis, there was no significance with Nexgen (p = 0.575). However, there was significant correlation between Scorpio (p = 0.011), Vanguard (p = 0.049) and no thumb test (3rd test). Especially, Scorpio had a tendency to dislocate the patella, but Vanguard to stabilize the patella. Conclusions No thumb test (3rd test) is correlated positively with 1st test, 2nd test, and post-osteotomy patella thickness. Therefore, the more patella osteotomy and the prosthesis with high affinity to patellofemoral alignment would be required for correct patella alignment. PMID:22162789

  18. Does the Utilization of Allograft Tissue in Medial Patellofemoral Ligament Reconstruction in Pediatric and Adolescent Patients Restore Patellar Stability?

    PubMed

    Hohn, Eric; Pandya, Nirav K

    2017-06-01

    Medial patellofemoral ligament (MPFL) reconstruction is one of several surgical procedures used to treat patellofemoral instability. Use of allograft tissue can preserve autogenous tissue and may be preferable in patients with connective tissue disorders or ligamentous laxity. Although there are successful reports in adults, it is unclear if the use of allograft tissue in MPFL reconstruction can restore patellofemoral stability in children and adolescents. (1) Does allograft tissue in MPFL reconstruction in pediatric and adolescent patients restore patellar stability? (2) What complications were associated with allograft MPFL reconstructions in children and adolescents? Between June 2012 and August 2015, one surgeon (NKP) performed 26 MPFL reconstructions in 23 patients with gracilis allograft for traumatic patellar instability. Of those, 25 (96%) were available for followup more than 1 year later (mean, 24 months; range, 12-44 months). During this time, the surgeon suggested reconstruction to patients who had recurrent dislocation or subluxation after 6 weeks of bracing, physical therapy, and activity modification if they were noted to have a torn or attenuated MPFL on MRI. During that period, this was the only surgical technique the surgeon used to treat traumatic patellar instability. Patients undergoing concurrent bony procedures were ineligible for inclusion. The mean age of the patients in the series was 16.0 (± 2) years. Age, sex, skeletal maturity, presence of trochlear dysplasia, and additional arthroscopic procedures at the time of reconstruction were collected. Postoperative notes and imaging were reviewed for presence of complications defined as recurrent dislocation, recurrent subluxations, fractures, infection, or arthrofibrosis. These complications were identified by chart review by the senior surgeon (NKP) and study personnel (EH) not involved in clinical care of the patients or by patient-reported complications. Recurrent subluxation or

  19. Incidence and Epidemiology of Patellar Fractures.

    PubMed

    Larsen, Peter; Court-Brown, Charles M; Vedel, Julie Odgaard; Vistrup, Sabina; Elsoe, Rasmus

    2016-11-01

    The literature lacks large-scale, up-to-date, population-based epidemiology studies on the incidence of patellar fractures based on complete populations. The purpose of this study was to provide up-to-date information concerning the incidence of patellar fractures in a large and complete population spanning a decade and to report on the distribution of fracture classification, trauma mechanisms, and patient baseline demographics. A retrospective review of clinical and radiological records of 756 patellar fractures treated between 2005 and 2014 was conducted. Mean age at the time of fracture was 54±21 years. Mean age was 46±22 years for males and 61±18 years for females. The sex distribution was 425 (56%) females and 331 (44%) males. The incidence of patellar fractures between 2005 and 2014 was 13.1/100,000/ year with a year-to-year variation between 10.5 and 16.5/100,000/year during the 10-year observation period. The distribution of incidence shows an increase with increasing age. Males have the highest incidence of fracture in the 10-to-19-year age group, approximately 15.4/100,000/year. Females in the 60-to-80-year age group have the highest incidence, approximately 36/100,000/year. AO type 34-C3 was the most common fracture type, representing 25% of all patellar fractures, followed by AO type 34-C1, representing 23%. [Orthopedics. 2016; 39(6):e1154-e1158.]. Copyright 2016, SLACK Incorporated.

  20. Radiographic Features of Acute Patellar Tendon Rupture.

    PubMed

    Fazal, Muhammad Ali; Moonot, Pradeep; Haddad, Fares

    2015-11-01

    The purpose of our study was to assess soft tissue features of acute patellar tendon rupture on lateral knee radiograph that would facilitate early diagnosis. The participants were divided into two groups of 35 patients each. There were 28 men and seven women with a mean age of 46 years in the control group and 26 men and nine women with a mean age of 47 years in the rupture group. The lateral knee radiograph of each patient was evaluated for Insall-Salvati ratio for patella alta, increased density of the infrapatellar fat pad, appearance of the soft tissue margin of the patellar tendon and bony avulsions. In the rupture group there were three consistent soft tissue radiographic features in addition to patellar alta. These were increased density of infrapatellar fat pad; loss of sharp, well-defined linear margins of the patellar tendon and angulated wavy margin of the patellar tendon while in the control group these features were not observed. The soft tissue radiographic features described in the rupture group are consistent and reliable. When coupled with careful clinical assessment, these will aid in early diagnosis and further imaging will be seldom required. © 2015 Chinese Orthopaedic Association and Wiley Publishing Asia Pty Ltd.

  1. Effects of a Knee Brace With a Patellar Hole Versus Without a Patellar Hole in Patients With Knee Osteoarthritis: A Double-Blind, Randomized Controlled Trial.

    PubMed

    Added, Marco Aurélio Nemitalla; Added, Caroline; Kasawara, Karina Tamy; Rotta, Viviane Perez; de Freitas, Diego Galace

    2017-01-01

    The objective of this study was to observe the immediate effect of a knee brace with a patellar hole versus without a patellar hole on pain perception in patients with knee osteoarthritis. To accomplish this, a double-blind, randomized controlled trial enrolled 108 patients divided into two groups (knee brace with a patellar hole or without a patellar hole). Patients were evaluated by the Visual Analogue Scale (VAS) in order to measure their pain sensation, the Timed Up and Go (TUG) test was used to evaluate their ability to walk, and the 8-m walking test (8MWT) was used to estimate their walking speed. Both groups presented significant reduction in pain perception, higher function of the lower extremities, and greater mobility while wearing a knee brace. However, the patients who wore a knee brace without a patellar hole presented more favorable results than those who wore a knee brace with a patellar hole: a 1.6-point reduction was found versus 1.1 points in the VAS, the patients presented 0.7 s less time versus 0.4 s in the TUG, and the speed was reduced by 1.4 s versus 0.8 s in the 8MWT. Therefore, the knee brace without a patellar hole presented more favorable results when compared with the knee brace with a patellar hole.

  2. Recession wedge trochleoplasty as an additional procedure in the surgical treatment of patellar instability with major trochlear dysplasia: early results.

    PubMed

    Thaunat, M; Bessiere, C; Pujol, N; Boisrenoult, P; Beaufils, P

    2011-12-01

    The importance of a dysplastic trochlea as a component of patellar instability has long been recognized. An original trochleoplasty technique consisting in retro-trochlear recession wedge osteotomy was described by Goutallier et al. The aim is not to fashion a groove but to reduce the bump without modifying patellofemoral congruence. This retrospective study reports the operative technique and short-term outcomes of a consecutive case series of 17 patients (19 knees) who underwent recession wedge trochleoplasty for patellofemoral instability associated with severe trochlear dysplasia. Other contributing factors of patellar instability were also corrected as part of the surgical procedure: tibial tuberosity transfer (n=18), MPFL reconstruction (n=8). Minimum follow-up was 12 months (mean, 34 months; range, 12 to 71 months). The trochlear prominence was reduced from a mean 4.8mm (range, 0 to 8mm) to -0.8mm (range, -8 to 6mm). Patellar tilt was reduced from a mean 14° (range, 6° to 26°) to 6° (range, -1° to 24°). Two cases showed recurrent patellofemoral instability. Mean Kujala, KOOS and IKDC score were respectively 80 (± 17), 70 (± 18) and 67 (± 17) at last follow-up. Three patients required further operations, apart from removal of metal screws: arthroscopic arthrolysis for stiffness (n=1), revision for tibial tuberosity non-union (n=1), and supratrochlear exostosectomy (n=1). Recession wedge trochleoplasty is a feasible additional procedure addressing bony trochlear abnormality in the surgical treatment of patellar instability. Our attitude is to perform it never in isolation but associated to realignment of the extensor apparatus according to the à la carte surgery concept. It seems to be effective in preventing future patellar dislocation and reducing anterior knee pain in case of painful patellofemoral instability with a major dysplastic trochlea, or in revision cases when other realignment procedures have failed. Copyright © 2011 Elsevier Masson SAS

  3. Does patellar rim electrocautery have deleterious effects on patellar cartilage?

    PubMed

    Namazi, Niloofar; Jaberi, Fereidoon Mojtahed; Pakbaz, Sara; Vosoughi, Amir Reza; Jaberi, Mahrad Mojtahed

    2014-03-01

    Circumpatellar electrocauterization to destroy pain receptors during total knee arthroplasty without patellar resurfacing is commonly used to decrease postoperative knee pain. We aimed to evaluate the effect of denervation with electrocauterization on patellar cartilage. Twenty rabbits were randomly assigned to two equally sized case and control groups. The rabbits in the case group underwent surgery via the anterior midline skin incision and medial parapatellar arthrotomy, followed by denervation electrocauterization at a depth of 1 mm and a distance of 3 mm from the outer border of the patella. In the control group, surgery was identical to that performed in the case group, but without patellar denervation. Twelve weeks after surgery, all rabbits were sacrificed. Range of motion, macroscopic evaluation of cartilage using modified Outerbridge scoring, and histopathological assessment using a modified histologic scoring system for cartilage were evaluated. Three rabbits died during the study. Nine cases and eight animals from the control group were included in the final evaluation. All rabbits had passive full range of motion. Mean Outerbridge score was 2.0 in the case group and 0.37 in the control group (p=0.002). There were statistically significant differences in cellularity (p=0.016), loss of matrix (p=0.004), and clustering of chondrocytes (p=0.008) between the two groups. Microscopic variables as a whole were statistically significant (p=0.001). Circumpatellar electrocauterization may result in cartilage destruction. So, we encourage caution in using routine electrocauterization in patients undergoing total knee arthroplasty. level II. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Successful treatment of a patient after sudden loss of the disc in a Björk-Shiley convexo-concave mitral prosthesis.

    PubMed

    Scalia, D; Giacomin, A; Da Col, U; Valfre, C

    1987-10-01

    The patient's survival after minor strut fracture and migration of a Björk-Shiley mitral prosthetic disc is presented. The operation was carried out in two stages: first emergency replacement of the mitral prosthesis and, later, elective removal of the dislocated disc.

  5. Comparison of patellofemoral outcomes after TKA using two prostheses with different patellofemoral design features.

    PubMed

    Bae, Dae Kyung; Baek, Jong Hun; Yoon, Kyung Tack; Son, Hyuck Sung; Song, Sang Jun

    2017-12-01

    The purpose of the present study was to compare the clinical and radiographic results after TKA using two prostheses with different sagittal patellofemoral design features, including outcomes related to compatibility of the patellofemoral joint. The clinical and radiographic results of 81 patients (100 knees) who underwent TKA using the specific prosthesis (group A) were compared with those in a control group who underwent TKA using the other prosthesis (group B). The presence of anterior knee joint pain, patellar crepitation, and patellar clunk syndrome was also checked. The function score and maximum flexion angle at the last follow-up were slightly better in group A than those in group B (92.0 ± 2.3 vs. 90.6 ± 4.2) (133.6° ± 8.4° vs. 129.6° ± 11.4°). Anterior knee pain was observed in 6 knees and patellar crepitation in four knees in group A. In group B, these symptoms were observed in 22 knees and 18 knees, respectively. There was no patellar clunk syndrome in either group. The alignment was corrected with satisfactory positioning of components. The patellar height remained unchanged after TKA in the two groups. The differences between preoperative and postoperative patellar tilt angle and patellar translation were small. When comparing the clinical and radiographic results after TKA using two prostheses with different sagittal patellofemoral design features, TKA using the specific prosthesis provided satisfactory results with less clinical symptoms related to the patellofemoral kinematics with TKA using the other prosthesis. III.

  6. A rare case report of Patellar Osteochondroma

    PubMed Central

    Bhatnagar, Abhinav S.; Malhan, Kaushal; Mehta, Sonu

    2015-01-01

    Introduction: Osteochondroma (OC) is the most common benign tumor of the skeleton. However, patellar OC is very rare. Only five case reports have been published yet and only 1 after the year 1972. OCs grow during childhood through adolescence, but usually growing ends when the epiphyseal plates close. In an adult, the growth of an OC suggests the diagnosis of malignant transformation to a chondrosarcoma. However, enlargement of a patellar OC reported as benign after skeletal maturity is present in literature. Case Report: We report the clinical and radiologic findings of a patellar OC in a 50-year-old female, with a 3-year progression of swelling, not painful, well-defined margins, normal skin, and no neurovascular deficits or functional impairment. The tumor was surgically resected, and histopathological examination did not show malignancy. After 2 years of follow-up, the patient has no complaints and no signs of recurrence. Conclusion: Patellar OCsare extremely rare with only a few reports published. It should be kept in mind that benign OCs can show symptomatic growth in skeletally mature patients without malignant transformation. PMID:27299076

  7. [Neglected ipsilateral simultaneous ruptures of patellar and quadriceps tendon].

    PubMed

    Karahasanoğlu, İlker; Yoloğlu, Osman; Kerimoğlu, Servet; Turhan, Ahmet Uğur

    2015-01-01

    Neglected patellar and quadriceps tendon rupture is a rare injury, but ipsilateral simultaneous patellar and quadriceps tendon rupture was not described in the literature to our knowledge. In this article, we report a 40-year-old healthy male patient with neglected ipsilateral patellar and quadriceps tendon ruptures treated by peroneus longus tendon autograft. Patient had received some conservative and surgical treatments for patellar fracture before applying to our clinic. After our treatment using peroneus longus autograft and interference nails, patient was immobilized for six weeks in cylindrical cast. Flexion exercises and full weight bearing were started after cast removal. Patient had no complaint at postoperative second year. Patient was a neglected case. Surgical repair and early rehabilitation enabled us to achieve a satisfactory outcome.

  8. Bilateral patellar tuberculosis masquerading as infected infrapatellar bursitis.

    PubMed

    Sreenivasan, Ravi; Haq, Rehan Ul

    2017-04-01

    A 30-year-old woman presented to our outpatient department with complaints of pain and swelling in bilateral infrapatellar regions and a discharging sinus in the right knee over the duration of one year. Radiographs showed lytic regions in bilateral patellae. Samples sent from material curetted from sinus yielded no organism but histopathology reported granulomatous inflammation. Following a fresh magnetic resonance imaging (MRI) scan that revealed the infrapatellar pad of fat communicating with the patellar lesions, an exploration and evacuation was done. Material sent revealed epithelioid cell granulomas with caseous necrosis consistent with tuberculosis (TB). The patient was put on first line anti-tubercular treatment (ATT) and has responded favourably with healing of sinus and patellar lesions. Bilateral infrapatellar bursitis is not rare. However patellar TB as a cause for OMIT is not a common diagnosis. A bilateral patellar involvement has not been reported in literature to the best of our knowledge.

  9. Repair of Medial Patellofemoral, Ligament Improves Patellar, Tracking in Total Knee Replacement.

    PubMed

    Meneghini, R Michael; Ziemba-Davis, Mary; Smits, Shelly; Bicos, James

    2015-11-01

    The medial patellofemoral ligament (MPFL) is essential to maintain patella stability; however, its role in total knee replacement (TKR) has not been studied. Forty-six consecutive TKRs in 40 patients were reviewed. Standard closure was performed in 29 TKRs. The MPFL was isolated and anatomically re-approximated in 17 subsequent TKRs. Blinded radiographic evaluation of patellar tilt and subluxation was performed preoperatively and 4 months postoperatively. Despite greater preoperative lateral tilt, the MPFL repair group demonstrated greater correction in patellar tilt compared with the standard closure group (p = 0.02). Patellar tracking also was optimized in the MPFL group, despite equivalent preoperative lateral patellar subluxation in the two groups. Simple repair of the MPFL at arthrotomy closure appears to optimize patellar stability radiographically and may improve long-term results by minimizing patellar complications and wear.

  10. Results of Lateral Retinacular Release Plus Circumpatellar Electrocautery in Total Knee Arthroplasty without Patellar Resurfacing.

    PubMed

    Wang, Yong; Sun, Jun-Ying; Zha, Guo-Chun

    2017-03-01

    Anterior knee pain (AKP) is integral to the overall success of total knee arthroplasty (TKA) without patellar resurfacing. Numerous studies have evaluated various factors that may contribute to AKP, including patellofemoral design, surgical technique, characteristics of the patient, and degree of chondromalacia. This study aims to explore whether patients who received lateral retinacular release (LRR) plus circumpatellar electrocautery (CE) in TKA attain a low incidence of AKP and whether the LRR plus CE increases postoperative complications. Between February 2001 and February 2009, all patients undergoing TKA without patellar resurfacing and LRR plus CE were evaluated. In total, 286 TKAs in 259 (88.7%) patients were available for assessment, with a mean of 9.3 ± 2.5 years (range: 6-14 years) after the index TKA. The patients were evaluated with a VAS and the Kujala patellofemoral score (KPS) for AKP and the Knee Society's clinical scoring system (KSS) for the clinical function. Satisfaction and LRR-related complications were also assessed. The mean KPS and KSS improved from 45.2 ± 12.9 and 75.4 ± 26.8 points preoperatively to 82.8 ± 10.0 and 151.6 ± 17.3 points at the final follow-up ( p  < 0.001), respectively. Subjectively, 5.6% (16 of 286) of patients suffered from AKP and 88.1% (252 of 286) were satisfied or very satisfied. Postoperative complications occurred in 15 (5.2%) patients, but these complications were mild and did not require reoperation. None of patients exhibited aseptic and septic prosthesis loosening and required revision surgery in the final follow-up. LRR plus CE appears to be a reasonable option in TKA without patellar resurfacing. It may achieve adequate mid-term results, with a low incidence of AKP and postoperative complications.The level of evidence of the study is therapeutic level IV. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  11. T2 mapping in patellar chondromalacia.

    PubMed

    Ruiz Santiago, Fernando; Pozuelo Calvo, Rocío; Almansa López, Julio; Guzmán Álvarez, Luis; Castellano García, María Del Mar

    2014-06-01

    To study the correlation between the T2 relaxation times of the patellar cartilage and morphological MRI findings of chondromalacia. This prospective study comprises 50 patients, 27 men and 23 women suffering of anterior knee pain (mean age: 29.7, SD 8.3 years; range: 16-45 years). MRI of 97 knees were performed in these patients at 1.5T magnet including sagittal T1, coronal intermediate, axial intermediate fat sat and T2 mapping. Chondromalacia was assessed using a modified version of Noyes classification. The relaxation time, T2, was studied segmenting the full thickness of the patellar cartilage in 12 areas: 4 proximal (external facet-proximal-lateral (EPL), external facet-proximal-central (EPC), internal facet-proximal-central (IPC), internal facet-proximal-medial (IPM), 4 in the middle section (external facet-middle-lateral (EML), external facet-middle-central (EMC), internal facet-middle-central (IMC), internal facet-middle-medial (IMM) and 4 distal (external facet-distal-lateral (EDL), external facet-distal-central (EDC), internal facet-distal-central (IDC), internal facet-distal-medial (IDM). T2 values showed a significant increase in mild chondromalacia regarding normal cartilage in most of the cartilage areas (p<0.05), except in the internal distal facet (IDC and IDM), EPC, EDL, and IMM. Severe chondromalacia was characterized by a fall of T2 relaxation times with loss of statistical significant differences in comparison with normal cartilage, except in EMC and IMC, where similar values as mild chondromalacia were maintained (p<0.05). Steepest increase in T2 values of patellar cartilage occurs in early stages of patellar cartilage degeneration. Progression of morphologic changes of chondromalacia to more severe degrees is associated to a new drop of T2 relaxation times approaching basal values in most of the areas of the patellar cartilage, except in the central area of the middle section, where T2 values remain increased. Copyright © 2014 Elsevier

  12. Sonoelastographic Features of the Patellar Ligament in Clinically Normal Dogs.

    PubMed

    Piccionello, Angela P; Serrani, Daniele; Busoni, Valeria; Salvaggio, Alberto; Bonazzi, Mattia; Bergamino, Chiara; Volta, Antonella

    2018-06-11

     This article describes the sonoelastographic features of the patellar ligament of sound dogs and tests feasibility, reproducibility and repeatability.  Clinically healthy medium-to-large breed dogs were enrolled. Sonoelastographic images of the patellar ligaments were obtained in lateral recumbency with the stifle flexed by an experienced operator and by a senior veterinary student. The elasticity colour map included red (soft), green (intermediate) and blue (hard). Tissue elasticity was measured by calculating the percentage of softness with dedicated software. Categorical, qualitative data analysis was performed using a weighted kappa statistic for repeatability and reproducibility. A categorical qualitative assessment was performed based on a grading scale of 1 to 5 (soft, mostly soft, intermediate, mostly hard and hard).  Fourteen clinically normal dogs were considered. A total of 28 patellar ligaments were examined. Overall, 25 of the patellar ligaments were graded as soft or mostly soft and the remaining 3 as intermediate. Repeatability was 86.2%, with a weighted kappa of 0.64 (good), for the well-trained sonographer and 83.3%, with a weighted kappa of 0.53 (moderate), for the senior student. Reproducibility was 86.2%, with a weighed kappa of 0.65 (good).  Sonoelastography of the canine patellar ligament is a feasible and reproducible technique. Patellar ligaments in clinically normal dogs showed highly elastic biomechanical properties. Schattauer GmbH Stuttgart.

  13. Patellar tendon healing with platelet-rich plasma: a prospective randomized controlled trial.

    PubMed

    de Almeida, Adriano Marques; Demange, Marco Kawamura; Sobrado, Marcel Faraco; Rodrigues, Marcelo Bordalo; Pedrinelli, André; Hernandez, Arnaldo José

    2012-06-01

    The patellar tendon has limited ability to heal after harvesting its central third. Platelet-rich plasma (PRP) could improve patellar tendon healing. Adding PRP to the patellar tendon harvest site would improve donor site healing and improve clinical outcome at 6 months after anterior cruciate ligament (ACL) reconstruction with a patellar tendon graft. Randomized controlled trial; Level of evidence, 1. Twenty-seven patients were randomly divided to receive (n = 12) or not receive (n = 15) PRP in the patellar tendon harvest site during ACL reconstruction. The primary outcome was magnetic resonance imaging (MRI) assessment of patellar tendon healing (gap area) after 6 months. Secondary outcomes were questionnaires and isokinetic testing of ACL reconstruction with a patellar tendon graft comparing both groups. Patellar tendon gap area was significantly smaller in the PRP group (4.9 ± 5.3 mm(2); 95% confidence interval [CI], 1.1-8.8) than in the control group (9.4 ± 4.4 mm(2); 95% CI, 6.6-12.2; P = .046). Visual analog scale score for pain was lower in the PRP group immediately postoperatively (3.8 ± 1.0; 95% CI, 3.18-4.49) than in the control group (5.1 ± 1.4; 95% CI, 4.24-5.90; P = .02). There were no differences after 6 months in questionnaire and isokinetic testing results comparing both groups. We showed that PRP had a positive effect on patellar tendon harvest site healing on MRI after 6 months and also reduced pain in the immediate postoperative period. Questionnaire and isokinetic testing results were not different between the groups at 6 months.

  14. CKS knee prosthesis: biomechanics and clinical results in 42 cases.

    PubMed

    Martucci, E; Verni, E; Del Prete, G; Stulberg, S D

    1996-01-01

    From 1991 to 1993 a total of 42 CKS prostheses were implanted for the following reasons: osteoarthrosis (34 cases), rheumatoid arthritis (7 cases) tibial necrosis (1 case). At follow-up obtained after 17 to 41 months the results were: excellent or good: 41; the only poor result was probably related to excessive tension of the posterior cruciate ligament. 94% of the patients reported complete regression of pain, 85% was capable of going up and down stairs without support. Mean joint flexion was 105 degrees. Radiologically the anatomical axis of the knee had a mean valgus of anatomical axis of the knee had a mean valgus of 6 degrees. The prosthetic components were always cemented. The posterior cruciate ligament was removed in 7 knees, so that the prosthesis with "posterior stability" was used. The patella was never prosthetized. One patient complained of peri-patellar pain two months after surgery which then regressed completely.

  15. Undisplaced Intraoperative Fracture Presenting as Early Dislocation with Tapered Wedge Stems in Total Hip Arthroplasty - Case Series and Review of Literature

    PubMed Central

    Reddy, A V Gurava; Eachempati, Krishna Kiran; Mugalur, Aakash; Suchinder, A; Rao, V B N Prasad; Kamurukuru, Nalanda

    2017-01-01

    Introduction: Periprosthetic fractures and dislocation in the early post-operative period can be disastrous both for the surgeon and the patient. However, undisplaced periprosthetic fractures presenting with dislocation is uncommon. We describe successful management of two cases (one bilateral dislocation and one unilateral dislocation) of undisplaced iatrogenic fractures in total hip arthroplasty (THA) presenting as early dislocation. Case Report: Case 1 was a 45-year-old female with osteoarthritis of hip secondary to developmental dysplasia of the hip with bilateral early nontraumatic dislocation with bilateral identical periprosthetic fracture. It was managed by revision to long stem and encirclage wiring. Case 2 presented with early dislocation in the 2nd week post THA. We found an intertrochanteric fracture intra-operatively with unstable implant. Acetabular component and femoral component revision were done with reconstruction of the greater trochanter. Discussion: These fractures could be occult iatrogenic fractures characteristic of taper wedge stems which presented as early nontraumatic dislocation in the post-operative period. The prosthesis subsidence, loss of muscle tension and change of version might be the factors leading to dislocation. Conclusion: Unrecognized incomplete intraoperative fracture can occur with tapered wedge uncemented stems which can present as a dislocation in the immediate post-operative period. This will require early revision of the femoral component. PMID:29051875

  16. Management of patellar fracture with titanium cable cerclage

    PubMed Central

    Huang, Sheng-Li; Xue, Jian-Li; Gao, Zong-Qiang; Lan, Bin-Shang

    2017-01-01

    Abstract Early rehabilitation after surgery for patellar fracture is challenging. The purpose of this study was to evaluate the surgical outcome of titanium cable cerclage for patellar fracture in early functional activity. We reviewed a series of 24 patients treated at our hospital with titanium cable. Functional exercises were started early. Patients were followed up for at least 12 months. Fifteen were males and 9 were females. Fracture occurred in the right knee in 13 patients and in the left knee in 11 patients. The most common mode of injury involves a tumble. None of the patients presented with any postoperative complications. The management resulted in satisfactory outcomes. Titanium cable cerclage offers a new strategy in treating patellar fracture. PMID:29095314

  17. Analysis of failed surgery for patellar instability in children with open growth plates.

    PubMed

    Nelitz, Manfred; Theile, Michael; Dornacher, Daniel; Wölfle, Julia; Reichel, Heiko; Lippacher, Sabine

    2012-05-01

    Many surgical procedures have been proposed to treat recurrent patellar dislocation in children. In recent years, a more tailored approach considering the underlying pathology has been advocated. The aim of the study was to analyze a group of patients with recurrent patellofemoral instability after unsuccessful operative stabilization (Roux-Goldthwait procedure, lateral release, medial reefing or in combination) in childhood and adolescence. A total of 37 children and adolescents with recurrent patellofemoral instability despite previous surgery were analyzed retrospectively. Radiographic examination included AP and lateral views to assess patella alta and limb alignment. MRI was performed to evaluate trochlear dysplasia and tibial tubercle-trochlear groove (TTTG) distance. As a control group, 23 age- and sex-matched adolescents that were treated with a favorable outcome after medial reefing alone or combined with a Roux-Goldthwait procedure were analyzed. Severe trochlear dysplasia (type B-D according to Dejour) as detected on MRI scans was found significantly more often in the study group (89%) than in the control group (21%). No statistical difference of patellar height ratio (Insall-Salvati index) and TTTG distance between the two groups could be found. Of the measured parameters, only the incidence of trochlear dysplasia was increased. Trochlear dysplasia therefore seems to be a major risk factor for failure of operative stabilization of recurrent patellofemoral instability in children and adolescents. The results in children are in consensus with the literature in adults that a more tailored operative therapy including reconstruction of the MPFL and trochleaplasty has to be considered. Retrospective study, Level III.

  18. Collagen-conjugated tracheal prosthesis tested in dogs without omental wrapping and silicone stenting.

    PubMed

    Liu, Yu; Lu, Tao; Zhang, Yongxing; Qiao, Yulei; Xi, Junjie; Wang, Qun

    2016-11-01

    Artificial tracheas fabricated from collagen-conjugated mesh appear to overcome fatal postoperative complications, namely anastomotic dehiscence and prosthesis dislocation. Such prostheses are incorporated by host tissue, provided they are wrapped in omentum (necessitating an additional abdominal procedure) and a silicone tube is used as a stent (to be extracted several weeks postoperatively). To mitigate related host impact (i.e. injury, pain and distress), we investigated the feasibility of implanting this type of tracheal prosthesis (∼5 cm in length) alone, without omental wrapping and use of a silicone stent. Porous-type tracheal prostheses that were reinforced with a continuous polypropylene spiral and sealed by collagen sponge from porcine skin replaced segments of cervical trachea (∼5 cm long) in 10 dogs through the method of telescopic anastomosis. Omental wrapping and silicone stent placement were omitted. Postoperatively, bronchoscopic examination was performed periodically. When dogs died or were sacrificed, tracheal prostheses were harvested for haematoxylin and eosin staining and electron microscopic scanning of luminal surface conditions. With the exception of one death from an anaesthesia-related incident during fibre-optic bronchoscopy (postsurgical week 1), nine dogs survived uneventfully (until sacrifice), without prosthesis dislocation or anastomotic dehiscence. The longest observation period was 2 years and 8 months. Bronchoscopic examination revealed that no stenosis or local infection was evident in the prostheses of five dogs. Moderate (n = 2) and slight (n = 2) stenoses were observed in the other four animals. All four animals survived for a long time, without dyspnoea or stridor. Histological examination showed that partial inner surface of the artificial trachea was covered with the pseudostratified ciliated epithelium. Regeneration of ciliated epithelium was also confirmed by scanning electron microscopy. This pilot study revealed

  19. Surface Area of Patellar Facets: Inferential Statistics in the Iraqi Population

    PubMed Central

    Al-Zamili, Zaid; Omar, Rawan

    2017-01-01

    Background. The patella is the largest sesamoid bone in the body; its three-dimensional complexity necessitates biomechanical perfection. Numerous pathologies occur at the patellofemoral unit which may end in degenerative changes. This study aims to test the presence of statistical correlation between the surface areas of patellar facets and other patellar morphometric parameters. Materials and Methods. Forty dry human patellae were studied. The morphometry of each patella was measured using a digital Vernier Caliper, electronic balance, and image analyses software known as ImageJ. The patellar facetal surface area was correlated with patellar weight, height, width, and thickness. Results. Inferential statistics proved the existence of linear correlation of total facetal surface area and patellar weight, height, width, and thickness. The correlation was strongest for surface area versus patellar weight. The lateral facetal area was found persistently larger than the medial facetal area, the p value was found to be <0.001 (one-tailed t-test) for right patellae, and another significant p value of < 0.001 (one-tailed t-test) was found for left patellae. Conclusion. These data are vital for the restoration of the normal biomechanics of the patellofemoral unit; these are to be consulted during knee surgeries and implant designs and can be of an indispensable anthropometric, interethnic, and biometric value. PMID:28348891

  20. High volume ultrasound guided injections at the interface between the patellar tendon and Hoffa's body are effective in chronic patellar tendinopathy: A pilot study.

    PubMed

    Crisp, Tom; Khan, Faisal; Padhiar, Nat; Morrissey, Dylan; King, John; Jalan, Rosy; Maffulli, Nicola; Frcr, Otto Chan

    2008-01-01

    To evaluate a novel conservative management modality for patellar tendinopathy. We recruited nine patients with patellar tendinopathy who had failed conservative management and showed evidence of neovascularisation on power Doppler scanning. A high volume ultrasound guided injection at the interface between the patellar tendon and Hoffa's body. The injection contained 10 ml 0.5% Bupivacaine, 25 mg Hydrocortisone, and between 12 and 40 ml normosaline. 100 mm visual analogue scales (VAS) for pain and for function, and Victorian Institute of Sport Assessment - Patellar tendon (VISA-P) questionnaires at an average of 9 months from the injection. All but one patient (whose pain was unchanged) improved (p = 0.028). The mean improvement in function 2 weeks after injection was 58 mm on VAS (interquartile range 27 - 88, p = 0.018). The mean improvement in pain 2 weeks after injection was 56 mm on a VAS scale (interquartile range 32 - 80, p = 0.018). At a mean follow up of 9 months, an improvement of 22 points from a baseline score of 46 on the VISA-P questionnaire (100 being normal) was established. High volume injections to mechanically disrupt the neovascularisation in patellar tendinopathy are helpful in the management of this condition. Controlled trials would be warranted to investigate in a more conclusive fashion this management modality.

  1. Biomechanical Analysis of a Novel Intercalary Prosthesis for Humeral Diaphyseal Segmental Defect Reconstruction.

    PubMed

    Zhao, Li-Ming; Tian, Dong-Mu; Wei, Yue; Zhang, Jun-Hui; Di, Zheng-Lin; He, Zhi-Yong; Hu, Yong-Cheng

    2018-02-01

    .66% and 11.16% under torsion after plate allied. The novel intercalary prosthesis has excellent ability to reconstruct humeral diaphyseal defects. The accessory fixation system, which included a plate and prosthesis, improved the rigidity of anti-tension and anti-torsion, and diminished the risk of prosthetic loosening and dislocation. A finite element analysis is a kind of convenient and practicable method to be used as the confirmation of experimental biomechanics study. © 2018 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.

  2. Biomechanical Assessment of Patellar Advancement Procedures for Patella Alta.

    PubMed

    Seidl, Adam; Baldini, Todd; Krughoff, Kevin; Shapiro, Joshua A; Lindeque, Bennie; Rhodes, Jason; Carollo, James

    2016-05-01

    Crouch gait deformity is common in children with cerebral palsy and often is associated with patella alta. Patellar tendon advancement typically is used to correct patella alta and restore normal knee mechanics. The purpose of this study was to determine the mechanical strength of surgical constructs used for fixation during patellar advancement procedures. This study used a cadaveric model to determine which of 3 surgical techniques is biomechanically optimal for patellar tendon advancement in treating patella alta. Twenty-four human cadaveric knees (8 per group) were prepared using 1 of 3 different common surgical techniques: tibial tubercle osteotomy, patellar tendon partial resection and repair at the distal patella, and patellar tendon imbrication. The patella was loaded from 25 to 250 N at 1 Hz for 1000 cycles. A significant difference in patella displacement under cyclical loading was found between surgical techniques. Tibial tubercle osteotomy exhibited significantly less displacement under cyclical loading than distal patella excision and repair (P<.0001) or imbrication (P=.0088). Imbrication exhibited significantly less displacement than distal patella excision and repair (P=.0006). Tibial tubercle osteotomy survived longest. Based on failure criteria of 5 mm of displacement, tibial tubercle osteotomy lasted between 250 and 500 cycles. The other 2 techniques failed by 25 cycles. This study offers quantitative evidence regarding the relative mechanical strength of each construct and may influence choice of surgical technique. [Orthopedics. 2016; 39(3):e492-e497.]. Copyright 2016, SLACK Incorporated.

  3. Should the position of the patellar component replicate the vertical median ridge of the native patella?

    PubMed

    Lee, Rae Hyeong; Jeong, Hae Won; Lee, Jin Kyu; Choi, Choong Hyeok

    2017-01-01

    In total knee arthroplasty (TKA), the position of the patellar component can affect patellar tracking. However, the patellar component cannot always replicate the original high point of the patella because of anatomical variance. This study investigated whether altering the highest point of the patella can affect outcomes of primary TKA, especially in patients having a patella with a far-medialized median ridge. A retrospective review was performed for 177 knees (143 patients) treated with primary TKA between July 2011 and March 2014. Group 1 (34 knees) had the patellar component displaced over three millimeters from the median ridge, while Group 2 (143 knees) had the patellar component placed on the original median ridge position. The one-year follow-up outcomes were reviewed, including: patellar tilt angle, Knee Society Score, Feller Patellar Score, and modified Kujala Anterior Knee Pain Score. Mean (±standard deviation) displacement of the patellar component in Group 1 was 3.97±0.97mm lateral to the original position of the median ridge, with a significant decrease in lateral patellar tilt angle (P<0.001). Lateral patellar tilt showed a positive correlation with the medialization of the patellar component (P<0.001, r=0.401). Ability to rise from a chair was better in Group 1 (P=0.025). There were no other between-group differences in other clinical outcomes. There should be no need for the patellar component to replicate the original highest point of the native patella in primary TKA. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Return to sport after patellar dislocation or following surgery for patellofemoral instability.

    PubMed

    Ménétrey, Jacques; Putman, Sophie; Gard, Suzanne

    2014-10-01

    Patellofemoral instability may occur in a young population as a result of injury during sporting activities. This review focuses on return to sport after one episode of dislocation treated no operatively and as well after surgery for chronic patellofemoral instability. With or without surgery, only two-thirds of patients return to sports at the same level as prior to injury. A high-quality rehabilitation programme using specific exercises is the key for a safe return to sporting activities. To achieve this goal, recovery of muscle strength and dynamic stability of the lower limbs is crucial. The focus should be directed to strengthen the quadriceps muscle and pelvic stabilizers, as well as lateral trunk muscle training. Patient education and regularly performed home exercises are other key factors that can lead to a successful return to sports. The criteria for a safe return to sports include the absence of pain, no effusion, a complete range of motion, almost symmetrical strength, and excellent dynamic stability. Level of evidence IV.

  5. Outcome and clinical signs of arthroscopically graded patellar chondromalacia with or without lateral release.

    PubMed

    Korkala, O L; Isotalo, T M; Lavonius, M I; Niskanen, R O

    1995-01-01

    In a follow-up study of 67 patients with an arthroscopically diagnosed patellar chondromalacia, we compared the results of plain conservative treatment with those after an open lateral retinacular release. The mean follow-up was 35 months. In Grade I chondromalacia the lateral release did not affect the result, which was in all cases good or excellent. In Grade II to IV chondromalacia the lateral release appeared beneficial, although the difference did not reach statistical significance. We also examined the validity of three clinical signs in arthroscopically verified patellar chondromalacia. Patellar inhibition and tracking tests were clearly more sensitive than the lateral apprehension test, which often gave a false negative result. If the patellar inhibition test is positive and a Grade II to IV chondromalacia of the patella is found at arthroscopy, lateral release should be considered among other procedures, like patellar shaving or patellar resurfacing.

  6. Differences in tendon properties in elite badminton players with or without patellar tendinopathy.

    PubMed

    Couppé, C; Kongsgaard, M; Aagaard, P; Vinther, A; Boesen, M; Kjaer, M; Magnusson, S P

    2013-03-01

    The aim of this study was to examine the structural and mechanical properties of the patellar tendon in elite male badminton players with and without patellar tendinopathy. Seven players with unilateral patellar tendinopathy (PT group) on the lead extremity (used for forward lunge) and nine players with no current or previous patellar tendinopathy (CT group) were included. Magnetic resonance imaging was used to assess distal patellar tendon dimensions. Patellar tendon mechanical properties were assessed using simultaneous tendon force and deformation measurements. Distal tendon cross-sectional area (CSA) normalized for body weight (mm(2) /kg(2/3) ) was lower in the PT group compared with the CT group on both the non-lead extremity (6.1 ± 0.3 vs 7.4 ± 0.2, P < 0.05) and the lead extremity (6.5 ± 0.6 vs 8.4 ± 0.3, P < 0.05). Distal tendon stress was higher in the PT group compared with the CT group for both the non-lead extremity (31 ± 1 vs 27 ± 1 MPa, P < 0.05) and the lead extremity (32 ± 3 vs 21 ± 3 MPa, P < 0.01). Conclusively, the PT group had smaller distal patellar tendon CSA on both the injured (lead extremity) and the uninjured side (non-lead extremity) compared with the CT group. Subsequently, the smaller CSA yielded a greater distal patellar tendon stress in the PT group. Therefore, a small tendon CSA may predispose to the development of tendinopathy. © 2012 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.

  7. Robot-aided in vitro measurement of patellar stability with consideration to the influence of muscle loading.

    PubMed

    Lorenz, Andrea; Bobrowitsch, Evgenij; Wünschel, Markus; Walter, Christian; Wülker, Nikolaus; Leichtle, Ulf G

    2015-07-23

    Anterior knee pain is often associated with patellar maltracking and instability. However, objective measurement of patellar stability under clinical and experimental conditions is difficult, and muscular activity influences the results. In the present study, a new experimental setting for in vitro measurement of patellar stability was developed and the mediolateral force-displacement behavior of the native knee analyzed with special emphasis on patellar tilt and muscle loading. In the new experimental setup, two established testing methods were combined: an upright knee simulator for positioning and loading of the knee specimens, and an industry robot for mediolateral patellar displacement. A minimally invasive coupling and force control mechanism enabled unconstrained motion of the patella as well as measurement of patellar motion in all six degrees of freedom via an external ultrasonic motion-tracking system. Lateral and medial patellar displacement were measured on seven fresh-frozen human knee specimens in six flexion angles with varying muscle force levels, muscle force distributions, and displacement forces. Substantial repeatability was achieved for patellar shift (ICC(3,1) = 0.67) and tilt (ICC(3,1) = 0.75). Patellar lateral and medial shift decreased slightly with increasing flexion angle. Additional measurement of patellar tilt provided interesting insights into the different displacement mechanisms in lateral and medial directions. For lateral displacement, the patella tilted in the same (lateral) direction, and tilted in the opposite direction (again laterally) for medial displacement. With regard to asymmetric muscle loading, a significant influence (p < 0.03, up to 5 mm shift and 8° tilt) was found for lateral displacement and a reasonable relationship between muscle and patellar force, whereas no effect was visible in the medial direction. The developed experimental setup delivered reproducible results and was found to be an excellent

  8. Custom-made ocular prosthesis.

    PubMed

    Gunaseelaraj, Rajkumar; Karthikeyan, Suma; Kumar, Mohan N; Balamurugan, T; Jagadeeshwaran, A R

    2012-08-01

    An ocular defect may affect a patient psychologically. An ocular prosthesis is given to uplift the patient psychologically and improve the confidence. Ocular prosthesis can be custom made or a stock shell. To improve the comfort and matching of the prosthesis with that of the adjacent natural eye an custom made ocular prosthesis is preferred. Different techniques are available to fabricate a custom ocular prosthesis, here we have used paper iris disk technique.

  9. Decline eccentric squats increases patellar tendon loading compared to standard eccentric squats.

    PubMed

    Kongsgaard, M; Aagaard, P; Roikjaer, S; Olsen, D; Jensen, M; Langberg, H; Magnusson, S P

    2006-08-01

    Recent studies have shown excellent clinical results using eccentric squat training on a 25 degrees decline board to treat patellar tendinopathy. It remains unknown why therapeutic management of patellar tendinopathy using decline eccentric squats offer superior clinical efficacy compared to standard horizontal eccentric squats. This study aimed to compare electromyography activity, patellar tendon strain and joint angle kinematics during standard and decline eccentric squats. Thirteen subjects performed unilateral eccentric squats on flat-and a 25 degrees decline surface. During the squats, electromyography activity was obtained in eight representative muscles. Also, ankle, knee and hip joint goniometry was obtained. Additionally, patellar tendon strain was measured in vivo using ultrasonography as subjects maintained a unilateral isometric 90 degrees knee angle squat position on either flat or 25 degrees decline surface. Patellar tendon strain was significantly greater (P<0.05) during the squat position on the decline surface compared to the standard surface. The stop angles of the ankle and hip joints were significantly smaller during the decline compared to the standard squats (P<0.001, P<0.05). Normalized mean electromyography amplitudes of the knee extensor muscles were significantly greater during the decline compared to the standard squats (P<0.05). Hamstring and calf muscle mean electromyography did not differ, respectively, between standard and decline squats. The use of a 25 degrees decline board increases the load and the strain of the patellar tendon during unilateral eccentric squats. This finding likely explains previous reports of superior clinical efficacy of decline eccentric squats in the rehabilitative management of patellar tendinopathy.

  10. Patellar tendon load in different types of eccentric squats.

    PubMed

    Frohm, A; Halvorsen, K; Thorstensson, A

    2007-07-01

    Differences in mechanical loading of the patellar tendon have been suggested as a reason for varying effects in rehabilitation of patellar tendinopathy using different eccentric squat exercises and devices. The aim was to characterize the magnitude and pattern of mechanical load at the knee and on the patellar tendon during four types of eccentric squat. Subjects performed squats with a submaximal free weight and with maximal effort in a device for eccentric overloading (Bromsman), on a decline board and horizontal surface. Kinematics was recorded with a motion-capture system, reaction forces with force plates, and electromyography from three leg muscles with surface electrodes. Inverse dynamics was used to calculate knee joint kinetics. Eccentric work, mean and peak patellar tendon force, and angle at peak force were greater (25-30%) for squats on decline board compared to horizontal surface with free weight, but not in Bromsman. Higher knee load forces (60-80%), but not work, were observed with Bromsman than free weight. Angular excursions at the knee and ankle were larger with decline board, particularly with free weight, and smaller in Bromsman than with free weight. Mean electromyography was greater on a decline board for gastrocnemius (13%) and vastus medialis (6%) with free weight, but in Bromsman only for gastrocnemius (7%). The results demonstrated clear differences in the biomechanical loading on the knee during different squat exercises. Quantification of such differences provides information that could be used to explain differences in rehabilitation effects as well as in designing more optimal rehabilitation exercises for patellar tendinopathy.

  11. [Comparison of early clinical effects of two hip prosthesis designs between ceramics to ceramics and metal to polyethylene].

    PubMed

    Yang, Li-qing; Li, Xi; Fu, Qin; Wang, Cheng

    2013-07-01

    To retrospectively study early therapeutic effects of the ceramics to ceramics prosthesis design in treating hip disease. From October 2007 to September 2010, 42 patients (44 hips) with hip disease underwent replacement of total hip. Hip prosthesis designs included the Pinnacle ceramics to ceramics and the Duraloc metal to polyethylene,produced by DePuy Company, all were non-bone cement type of artificial hip joint. Twenty patients (22 hips) were performed with ceramics to ceramics total hip prosthesis (CoC group, there were 12 males and 8 females, aged from 21 to 49 years) and 22 patients (22 hips) were performed with metal to polyethylene total hip prosthesis (MoP group, there were 13 males and 9 females, aged from 42 to 55 years). All the surgical approachs were posterolateral, and the routine anticoagulation and the corresponding functional exercise were performed after operation. The follow-up time was 6 months at least including clinical and radiographic observation. Measured the motion of joint and evaluated the function of hip joint according to Harris classification. All clinical effects were satisfactory and no dislocation ,loosening,infection, deep venous thrombosis and other complications occurred. There was no statistical significance in Harris scoring and the motion of joint between two groups before and after operation (P>0.05). The clinical effect of ceramics to ceramics prosthesis design in improving clinical symptoms and the motion of joint is coordinate with metal to polyethylene total hip prosthesis, however, its advantages and long-term efficacy need further observing. The ceramics to ceramics prosthesis design may be a good choice for the young patients with hip disease because of its good wear resistance.

  12. [Distal fixation prosthesis for unstable intertrochanteric fractures in elderly patients: a mid-term follow-up study].

    PubMed

    Zhang, Zhan-feng; Min, Ji-kang; Zhong, Jian-ming; Wang, Dan

    2016-06-01

    To explore mid-term follow up results of distal fixation prosthesis in treating unstable intertrochanteric fractures in elderly patients. From May 2008 to March 2014,58 elderly patients with unstable intertrochanteric were treated with distal fixation prosthesis, among them, there were 15 males and 43 females aged from 75 to 87 years old with an average of 83.2 years old. Fracture were classified according to Evans classification, 39 cases were type I c and 19 cases were type I d. Surgical risk was evaluated before operation, 9 patients were performed total hip arthroplasty and 49 patients were performed prosthetic replacement hip joint function of patients with different age period, Evans classificaton, prothesis type, fixation method were evaluated respectively by using Harris score. Fifty-six patients were followed up from 13 to 36 months with an average of 21.6 months. Harris score was 83.51 ± 6.40, 5 cases got excellent results, 38 cases good and 13 cases moderate. Harris score of patients aged from 75 to 80 years old was 88.64 ± 2.35, 81.64 ± 6.40 in patients aged more than 80 years old, and had significant differences between two groups; Harris score in patients with type Evans I c was 83.64 ± 6.53, and 83.11 ± 6.08 in type Evans I d, while there was no significant differences between two groups. There was no obvious meaning in Harris score between patients with tension band (83.63 ± 6.15) and without tension band (82.41 ± 6.57). There was no significant meaning in Harris score between patients with normal distal fixation prosthesis (83.34 ± 6.43) and femoral moment reconstruction distal fixation prosthesis (83.92 ± 6.51). There was 1 patient occurred hip joint dislocation on the operative side and re-dislocation after manual reduction, then received open reduction. Two patients occurred femoral osteolysis without clinical symptoms, and treated conservative treatment. Artificial joint replacement for unstable intertrochanteric fractures in elderly

  13. Patellar tendinopathy: late-stage results from surgical treatment☆

    PubMed Central

    Cenni, Marcos Henrique Frauendorf; Silva, Thiago Daniel Macedo; do Nascimento, Bruno Fajardo; de Andrade, Rodrigo Cristiano; Júnior, Lúcio Flávio Biondi Pinheiro; Nicolai, Oscar Pinheiro

    2015-01-01

    Objective To evaluate the late-stage results from surgical treatment of patellar tendinopathy (PT), using the Visa score (Victorian Institute of Sport Tendon Study Group) and the Verheyden method. Methods This was a retrospective study in which the postoperative results from 12 patients (14 knees) who were operated between July 2002 and February 2011 were evaluated. The patients included in the study presented patellar tendinopathy that was refractory to conservative treatment, without any other concomitant lesions. Patients who were not properly followed up during the postoperative period were excluded. Results Using the Verheyden method, nine patients were considered to have very good results, two had good results and one had poor results. In relation to Visa, the mean was 92.4 points and only two patients had scores less than 70 points (66 and 55 points). Conclusion When surgical treatment for patellar tendinopathy is correctly indicated, it has good long-term results. PMID:26535202

  14. Arthroscopic treatment of chronic patellar tendinopathy in high-level athletes

    PubMed Central

    Alaseirlis, Dimosthenis Artemis; Konstantinidis, George Athanasios; Malliaropoulos, Nikolaos; Nakou, Lamprini Stefanos; Korompilias, Anastasios; Maffulli, Nicola

    2012-01-01

    Summary To present the results of arthroscopic treatment of patellar tendinopathy in high-level competition athletes. Eleven high-level athletes presented chronic patellar tendinopathy which did not respond to long term conservative treatment. Average age of the patients was 24.8 ±3.4 years old. All patients received an arthroscopic procedure with osteoplasty of the distal patellar pole, debridement of the underlying Hoffa fat pad and of the degenerated areas of the proximal posterior patella tendon and cauterization of the visible neo-vessels. Mean duration of follow-up was 17.4±4 months. Patients showed a major improvement in the Lysholm score from 49.9±5.2 to 92.5±7 and in the VISA P score from 41.2±5.2 to 86.8±14.9 on tenth post-operative week. All patients had returned to sports activities by the twelfth postoperative week. Arthroscopic treatment of chronic patellar tendinopathy found to be a minimal invasive and safe technique which produced satisfactory results. PMID:23738308

  15. Women's Satisfaction with Their Breast Prosthesis: What Determines a Quality Prosthesis?

    ERIC Educational Resources Information Center

    Livingston, Patricia M.; White, Victoria M.; Roberts, Susan B.; Pritchard, Emma; Hayman, Jane; Gibbs, Anne; Hill, David J.

    2005-01-01

    The aim of this study is to determine what factors constitute a quality prosthesis and ascertain which factors affect prosthesis satisfaction. Sixty-four women who received full funding for their prosthesis and 38 women who received their hospital's usual funding were recruited. Women rated the information provided about breast prostheses very…

  16. Dislocations

    MedlinePlus

    ... or a blow, sometimes from playing a contact sport. You can dislocate your ankles, knees, shoulders, hips, ... to dislocate it again. Wearing protective gear during sports may help prevent dislocations.

  17. Correlation of 3D Shift and 3D Tilt of the Patella in Patients With Recurrent Dislocation of the Patella and Healthy Volunteers: An In Vivo Analysis Based on 3-Dimensional Computer Models.

    PubMed

    Yamada, Yuzo; Toritsuka, Yukiyoshi; Nakamura, Norimasa; Horibe, Shuji; Sugamoto, Kazuomi; Yoshikawa, Hideki; Shino, Konsei

    2017-11-01

    The concepts of lateral deviation and lateral inclination of the patella, characterized as shift and tilt, have been applied in combination to evaluate patellar malalignment in patients with patellar dislocation. It is not reasonable, however, to describe the 3-dimensional (3D) positional relation between the patella and the femur according to measurements made on 2-dimensional (2D) images. The current study sought to clarify the relation between lateral deviation and inclination of the patella in patients with recurrent dislocation of the patella (RDP) by redefining them via 3D computer models as 3D shift and 3D tilt. Descriptive laboratory study. Altogether, 60 knees from 56 patients with RDP and 15 knees from 10 healthy volunteers were evaluated. 3D shift and tilt of the patella were analyzed with 3D computer models created by magnetic resonance imaging scans obtained at 10° intervals of knee flexion (0°-50°). 3D shift was defined as the spatial distance between the patellar reference point and the midsagittal plane of the femur; it is expressed as a percentage of the interepicondylar width. 3D tilt was defined as the spatial angle between the patellar reference plane and the transepicondylar axis. Correlations between the 2 parameters were assessed with the Pearson correlation coefficient. The patients' mean Pearson correlation coefficient was 0.895 ± 0.186 (range, -0.073 to 0.997; median, 0.965). In all, 56 knees (93%) had coefficients >0.7 (strong correlation); 1 knee (2%), >0.4 (moderate correlation); 2 knees (3%), >0.2 (weak correlation); and 1 knee (2%), <0.2 (no correlation). The mean correlation coefficient of the healthy volunteers was 0.645 ± 0.448 (range, -0.445 to 0.982; median, 0.834). A statistically significant difference was found in the distribution of the correlation coefficients between the patients and the healthy volunteers ( P = .0034). When distribution of the correlation coefficients obtained by the 3D analyses was compared with that

  18. Re-revision of a patellar tendon rupture in a young professional martial arts athlete.

    PubMed

    Vadalà, A; Iorio, R; Bonifazi, A M; Bolle, G; Ferretti, A

    2012-09-01

    A 27-year-old professional martial arts athlete experienced recurrent right knee patellar tendon rupture on three occasions. He underwent two operations for complete patellar tendon rupture: an end-to-end tenorrhaphy the first time, and revision with a bone-patellar-tendon (BPT) allograft. After the third episode, he was referred to our department, where we performed a surgical reconstruction with the use of hamstring pro-patellar tendon, in a figure-of-eight configuration, followed by a careful rehabilitation protocol. Clinical and radiological follow-ups were realized at 1, 3, and 6 months and 1 and 2 years postop, with an accurate physical examination, the use of recognized international outcome scores, and radiograph and MRI studies. As far as we know, this is the first paper to report a re-revision of a patellar tendon rupture.

  19. Patellar tendon re-rupture on the opposite end of the previous site of surgical repair

    PubMed Central

    KOH, Bryan Thean Howe; SAYAMPANATHAN, Andrew A; LEE, Keng Thiam

    2017-01-01

    We describe a rare case of a patellar tendon “re-rupture” at the opposite end of a previous proximal tendon repair. A 32-year-old male with a history of surgically repaired right proximal patellar tendon rupture presented with an acute non-traumatic right knee pain and instability during sports. Magnetic resonance imaging confirmed a complete rupture of his distal patellar tendon at the tibial tuberosity. The patellar tendon was repaired using two 5.5 mm BioCorkscrews (Arthrex) inserted into the tibial tuberosity; the tendon was stitched with the No. 2 fiberwires using Krackow technique. As the patellar tendon was degenerative, the repair was augmented with a semitendinosus tendon harvested using an open tendon stripper, leaving the distal attachment intact. At 2.6 years followup he had mild anterior knee pain, range of motion 0-130° and was able to squat. MRI scan done at followup revealed good healing of repaired patellar tendon. PMID:28566788

  20. In Vivo Patellar Tracking and Patellofemoral Cartilage Contacts during Dynamic Stair Ascending

    PubMed Central

    Suzuki, Takashi; Hosseini, Ali; Li, Jing-Sheng; Gill, Thomas J; Li, Guoan

    2012-01-01

    The knowledge of normal patellar tracking is essential for understanding of the knee joint function and for diagnosis of patellar instabilities. This paper investigated the patellar tracking and patellofemoral joint contact locations during a stair ascending activity using a validated dual-fluoroscopic imaging system. The results showed that the patellar flexion angle decreased from 41.9° to 7.5° with the knee extension during stair ascending. During first 80% of the activity, the patella shifted medially about 3.9 mm and then slightly shifted laterally during the last 20% of the ascending activity. Anterior translation of 13 mm of the patella was measured at the early 80% of the activity and then slightly moved posteriorly by about 2 mm at the last 20% of the activity. The path of the cartilage contact points was slightly lateral on the cartilage surfaces of patella and femur. On the patellar cartilage surface, the cartilage contact locations were about 2 mm laterally from heel strike to 60% of the stair ascending activity and moved laterally and reached 5.3 mm at full extension. However, the cartilage contact locations were relatively constant on the femoral cartilage surface (~5 mm lateral). The patellar tracking pattern was consistent with the patellofemoral cartilage contact location pattern. These data could provide baseline knowledge for understanding of normal physiology of the patellofemoral joint and can be used as a reference for clinical evaluation of patellofemoral disorder symptoms. PMID:22840488

  1. The influence of intraoperative soft tissue balance on patellar pressure in posterior-stabilized total knee arthroplasty.

    PubMed

    Matsumoto, Tomoyuki; Shibanuma, Nao; Takayama, Koji; Sasaki, Hiroshi; Ishida, Kazunari; Matsushita, Takehiko; Kuroda, Ryosuke; Kurosaka, Masahiro

    2016-06-01

    Appropriate soft tissue balance is essential for the success of total knee arthroplasty (TKA), and assessment with an offset-type tensor provides useful information about the femorotibial (FT) joint. The purpose of the study was to investigate the relationship between intraoperative soft tissue balance and patellar pressure at both medial and lateral sides. Thirty varus-type osteoarthritis patients who received mobile-bearing posterior-stabilized TKAs were enrolled in the study. Using the tensor, soft tissue balance, including joint component gap and varus ligament balance, was recorded at 0°, 10°, 30°, 60°, 90°, 120°, and 135° with patellofemoral (PF) joint reduction and femoral component placement. Following final prostheses implanted with appropriate insert, the medial and lateral patellar pressures were measured at each flexion angle. A simple regression analysis was performed between each patellar pressure, parameter of soft tissue balance, and postoperative flexion angle. Both lateral and medial patellar pressures increased with flexion. The lateral patellar pressure was significantly higher than the medial patellar pressure at 60°, 90°, and 135° of flexion (p<0.05). The lateral patellar pressure inversely correlated with the varus ligament balance at 60° and 90° of flexion (p<0.05). The lateral patellar pressure at 120° and 135° of flexion inversely correlated with the postoperative flexion angle (p<0.05). Soft tissue balance influenced patellar pressure. In particular, a reduced lateral patellar pressure was found at the lateral laxity at flexion, leading to high postoperative flexion angle. III. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Management of bilateral patellar luxation in an alpaca.

    PubMed

    Abuja, Gustavo A; Kowaleski, Michael P; García-López, José M

    2014-05-01

    To report surgical management bilateral lateral patellar luxation in a mature alpaca using a combination of trochlear wedge recession (TWR), tibial tuberosity transposition (TTT), and joint capsule imbrication. Clinical case report. 9-year-old castrated male Alpaca. Bilateral, grade III/IV, lateral patellar luxation was identified by palpation, lameness examination and confirmed with radiography and ultrasonography. Surgical procedures were staged, with the left stifle treated first. Bilateral TWR, TTT, and joint capsule imbrication were performed. Outcome was assessed by radiography and follow up lameness examinations. An immediate improvement in weight bearing occurred after surgery of the left hind limb. Five months after initial surgery, right hind limb patella luxation was corrected. After surgery on the 2nd limb, the alpaca had progressive improvement in weight bearing during hospitalization. At 12 months, there were no signs of lameness and the alpaca had resumed normal activities. For bilateral lateral patellar luxation, a combination of TWR, TTT, and joint capsule imbrication resulted in excellent long-term outcome. © Copyright 2014 by The American College of Veterinary Surgeons.

  3. Similar patient-reported outcomes and performance after total knee arthroplasty with or without patellar resurfacing

    PubMed Central

    Ali, Abdulemir; Lindstrand, Anders; Nilsdotter, Anna; Sundberg, Martin

    2016-01-01

    Background and purpose Knee pain after total knee arthroplasty (TKA) is not uncommon. Patellar retention in TKA is one cause of postoperative knee pain, and may lead to secondary addition of a patellar component. Patellar resurfacing in TKA is controversial. Its use ranges from 2% to 90% worldwide. In this randomized study, we compared the outcome after patellar resurfacing and after no resurfacing. Patients and methods We performed a prospective, randomized study of 74 patients with primary osteoarthritis who underwent a Triathlon CR TKA. The patients were randomized to either patellar resurfacing or no resurfacing. They filled out the VAS pain score and KOOS questionnaires preoperatively, and VAS pain, KOOS, and patient satisfaction 3, 12, and 72 months postoperatively. Physical performance tests were performed preoperatively and 3 months postoperatively. Results We found similar scores for VAS pain, patient satisfaction, and KOOS 5 subscales at 3, 12, and 72 months postoperatively in the 2 groups. Physical performance tests 3 months postoperatively were also similar in the 2 groups. No secondary resurfacing was performed in the group with no resurfacing during the first 72 months Interpretation Patellar resurfacing in primary Triathlon CR TKA is of no advantage regarding pain, physical performance, KOOS 5 subscales, or patient satisfaction compared to no resurfacing. None of the patients were reoperated with secondary addition of a patellar component within 6 years. According to these results, routine patellar resurfacing in primary Triathlon TKA appears to be unnecessary. PMID:27212102

  4. Patellar fixation protected with a load-sharing cable: a mechanical and clinical study.

    PubMed

    Perry, C R; McCarthy, J A; Kain, C C; Pearson, R L

    1988-01-01

    The stability of patellar fracture fixation protected with a load-sharing cable was studied in cadavers. A transverse patellar osteotomy was produced and stabilized with standard patellar fixation with or without a figure-of-eight cable that extends from the proximal pole of the patella to the tibial tubercle. Standard fixation techniques (interfragmentary cancellous screws or modified tension-band wiring) alone failed after significantly fewer cycles of flexion and extension than did the same fixation when supplemented with a load-sharing cable. In the clinical evaluation of the load-sharing cable, 14 consecutive patients with displaced patellar fractures were treated. No immobilization was used and the patients were started on passive and active range of motion and weight-bearing ambulation in the early postoperative period. Thirteen fractures healed uneventfully. The increased stability of patellar fracture fixation protected with a load-sharing cable offers three advantages: (a) adjunctive casting is unnecessary, (b) comminuted fractures can be "pieced" together anatomically with less concern for loss of fixation, and (c) early postoperative passive and active range of motion can be achieved.

  5. [Mid-term effectiveness of rotating hinge knee prosthesis for severe knee deformity].

    PubMed

    Zeng, Min; Hu, Yihe; Xie, Jie; Li, Mingqing; Lin, Shaoru

    2014-01-01

    To evaluate the mid-term effectiveness of rotating hinge knee prosthesis for severe knee deformity. A retrospective analysis was made on the clinical data of 24 patients (24 knees) who received rotating hinge knee prosthesis for total knee arthroplasty between January 2003 and June 2011. There were 14 males and 10 females, aged from 60 to 81 years (mean, 70 years). The disease causes included osteoarthritis in 5 cases, rheumatoid arthritis in 7 cases, traumatic arthritis in 9 cases, and Charcot's arthropathy in 3 cases. The disease duration ranged from 5 to 25 years (mean, 14.5 years). Of them, 13 cases had flexion deformity, 7 cases had valgus deformity, and 16 cases had varus deformity. The operation time, the amount of bleeding between operation and drainage-tubes removal, hospitalization time, incision healing, and complications were recorded. The results were evaluated according to Knee Society Score (KSS), visual analogue scale (VAS), and the range of motion (ROM) of knee. Short-form 36 health survey scale (SF-36) was used to evaluate the life quality of patients. The position of prosthesis was observed through X-ray examination. The operation time ranged from 70 to 90 minutes (mean, 78 minutes). The amount of bleeding between operation and drainage-tubes removal ranged from 400 to 1 000 mL (mean, 650 mL). The hospitalization time ranged from 14 to 18 days (mean, 15.2 days). Patellar fracture occurred in 1 case (4.17%) during operation, swelling and effusion of incision in 1 case (4.17%), and periprosthetic infections in 2 cases (8.33%) after operation. All patients were followed up 2-10 years (mean, 5.5 years). The X-ray films showed no evidence of obvious radiolucent line, osteolysis, prosthesis subsidence, and limb alignment change. The results of KSS, VAS socres, and ROM of knee at 1 year postoperatively and last follow-up were significantly better than preoperative ones (P < 0.05), but no significant difference was found between at 1 year postoperatively

  6. Relationship between patellar mobility and patellofemoral joint cartilage degeneration after anterior cruciate ligament reconstruction.

    PubMed

    Ota, Susumu; Kurokouchi, Kazutoshi; Takahashi, Shigeo; Yoda, Masaki; Yamamoto, Ryuichiro; Sakai, Tadahiro

    2017-11-01

    Patellofemoral cartilage degeneration is a potential complication of anterior cruciate ligament reconstruction (ACLR) surgery. Hypomobility of the patella in the coronal plane is often observed after ACLR. Few studies, however, have examined the relationship between cartilage degeneration in the patellofemoral joint and mobility after ACLR. The present study investigated 1) the coronal mobility of the patella after ACLR, 2) the relationship between patellar mobility and cartilage degeneration of the patellofemoral joint, and 3) the relationship between patellar mobility and knee joint function after ACLR. Forty patients who underwent medial hamstring-based ACLR participated in the study. Lateral and medial patellar displacements were assessed with a modified patellofemoral arthrometer, and the absolute values of the displacements were normalized to patient height. The International Cartilage Repair Society (ICRS) cartilage injury classification of the patellar and femoral (trochlear) surfaces, and the Lysholm Knee Scoring Scale were used to evaluate knee function. Lateral and medial patellar displacements were reduced compared with the non-operated knee at the second-look arthroscopy and bone staple extraction operation (second operation; 24.4 ± 7.9 months after ACLR, P<0.01). The ICRS grades of the patellofemoral joint (patella and trochlea) were significantly worse than those pre-ACLR. Neither lateral nor medial patellar mobility, however, were significantly correlated with the ICRS grade or the Lysholm score. Although patellar mobility at approximately 2 years after ACLR was decreased compared to the non-operated knee, small displacement of the patella was not related to cartilage degeneration or knee joint function at the time of the second operation.

  7. Younger age increases the risk of early prosthesis failure following primary total knee replacement for osteoarthritis. A follow-up study of 32,019 total knee replacements in the Finnish Arthroplasty Register.

    PubMed

    Julin, Jaakko; Jämsen, Esa; Puolakka, Timo; Konttinen, Yrjö T; Moilanen, Teemu

    2010-08-01

    Total knee replacements (TKRs) are being increasingly performed in patients aged < or = 65 years who often have high physical demands. We investigated the relation between age of the patient and prosthesis survival following primary TKR using nationwide data collected from the Finnish Arthroplasty Register. From Jan 1, 1997 through Dec 31, 2003, 32,019 TKRs for primary or secondary osteoarthritis were reported to the Finnish Arthroplasty Register. The TKRs were followed until the end of 2004. During the follow-up, 909 TKRs were revised, 205 (23%) due to infection and 704 for other reasons. Crude overall implant survival improved with increasing age between the ages of 40 and 80. The 5-year survival rates were 92% and 95% in patients aged < or = 55 and 56-65 years, respectively, compared to 97% in patients who were > 65 years of age (p < 0.001). The difference was mainly attributable to reasons other than infections. Sex, diagnosis, type of TKR (condylar, constrained, or hinge), use of patellar component, and fixation method were also associated with higher revision rates. However, the differences in prosthesis survival between the age groups < or = 55, 56-65, and > 65 years remained after adjustment for these factors (p < 0.001). Young age impairs the prognosis of TKR and is associated with increased revision rates for non-infectious reasons. Diagnosis, sex, type of TKR, use of patellar component, and fixation method partly explain the differences, but the effects of physical activity, patient demands, and obesity on implant survival in younger patients warrant further research.

  8. [Analysis of the failures of a cemented constrained liner model in patients with a high dislocation risk].

    PubMed

    Gallart, X; Gomez, J C; Fernández-Valencia, J A; Combalía, A; Bori, G; García, S; Rios, J; Riba, J

    2014-01-01

    To evaluate the short-term results of an ultra high molecular weight polyethylene retentive cup in patients at high risk of dislocation, either primary or revision surgery. Retrospective review of 38 cases in order to determine the rate of survival and failure analysis of a constrained cemented cup, with a mean follow-up of 27 months. We studied demographic data, complications, especially re-dislocations of the prosthesis and, also the likely causes of system failure analyzed. In 21.05% (8 cases) were primary surgery and 78.95% were revision surgery (30 cases). The overall survival rate by Kaplan-Meier method was 70.7 months. During follow-up 3 patients died due to causes unrelated to surgery and 2 infections occurred. 12 hips had at least two previous surgeries done. It wasn't any case of aseptic loosening. Four patients presented dislocation, all with a 22 mm head (P=.008). Our statistical analysis didn't found relationship between the abduction cup angle and implant failure (P=.22). The ultra high molecular weight polyethylene retentive cup evaluated in this series has provided satisfactory short-term results in hip arthroplasty patients at high risk of dislocation. Copyright © 2014 SECOT. Published by Elsevier Espana. All rights reserved.

  9. Robotic lower limb prosthesis design through simultaneous computer optimizations of human and prosthesis costs

    NASA Astrophysics Data System (ADS)

    Handford, Matthew L.; Srinivasan, Manoj

    2016-02-01

    Robotic lower limb prostheses can improve the quality of life for amputees. Development of such devices, currently dominated by long prototyping periods, could be sped up by predictive simulations. In contrast to some amputee simulations which track experimentally determined non-amputee walking kinematics, here, we explicitly model the human-prosthesis interaction to produce a prediction of the user’s walking kinematics. We obtain simulations of an amputee using an ankle-foot prosthesis by simultaneously optimizing human movements and prosthesis actuation, minimizing a weighted sum of human metabolic and prosthesis costs. The resulting Pareto optimal solutions predict that increasing prosthesis energy cost, decreasing prosthesis mass, and allowing asymmetric gaits all decrease human metabolic rate for a given speed and alter human kinematics. The metabolic rates increase monotonically with speed. Remarkably, by performing an analogous optimization for a non-amputee human, we predict that an amputee walking with an appropriately optimized robotic prosthesis can have a lower metabolic cost - even lower than assuming that the non-amputee’s ankle torques are cost-free.

  10. Quantitative assessment of patellar vascularity following bone-patellar tendon-bone autograft harvest for ACL reconstruction.

    PubMed

    Jones, Kristofer J; Lazaro, Lionel E; Taylor, Samuel A; Pardee, Nadine C; Dyke, Jonathan P; Hannafin, Jo A; Warren, Russell F; Lorich, Dean G

    2016-09-01

    Recent anatomic studies have suggested that the dominant arterial supply of the patella enters through the inferior pole. Based upon these findings, we hypothesized that bone-patellar tendon-bone graft harvest can significantly diminish patellar vascularity. Nine matched pair cadaveric knee specimens (mean age 47.4 years) were dissected and cannulated. A single knee was selected to undergo routine graft harvest, and the contralateral knee was left intact to serve as a control. Gadolinium was injected, and magnetic resonance imaging (MRI) signal enhancement was quantified to determine differences in uptake. Each matched pair was subsequently injected with a urethane polymer compound and dissected to correlate vessel disruption with MRI findings. We identified two predominating patterns of vessel entry. In one pattern, the vessel entered the inferomedial aspect (five o'clock/right, seven o'clock/left) of the patella and was disrupted by graft harvest in 2/9 (22.2 %) pairs. In the second pattern, the vessel entered further medial (four o'clock/right, eight o'clock/left) and was not disrupted (7/9, 78.8 %). The mean decrease in gadolinium uptake following disruption of the predominant vessel measured 56.2 % (range 42.6-69.5 %) compared to an average decrease of 18.3 % (range 7.1-29.1 %) when the dominant arterial supply to the inferior pole remained intact (p < 0.04). Medial entry of the predominant vessel precluded vessel disruption. Disruption of the dominant arterial supply can result in a significant decrease in patellar vascularity. Modification of graft harvest techniques and areas of surgical dissection should be explored to minimize vascular insult. Further correlation with clinical studies/outcomes is necessary to determine a potential association between vascular insult and anterior knee pain.

  11. Superior-inferior position of patellar component affects patellofemoral kinematics and contact forces in computer simulation.

    PubMed

    Nakamura, Shinichiro; Tanaka, Yoshihisa; Kuriyama, Shinichi; Nishitani, Kohei; Ito, Hiromu; Furu, Moritoshi; Matsuda, Shuichi

    2017-06-01

    Anterior knee pain has been reported as a major postoperative complication after total knee arthroplasty, which may lead to patient dissatisfaction. Rotational alignment and the medial-lateral position correlate with patellar maltracking, which can cause knee pain postoperatively. However, the superior-inferior position of the patellar component has not been investigated. The purpose of the current study was to investigate the effects of the patellar superior-inferior position on patellofemoral kinematics and kinetics. Superior, central, and inferior models with a dome patellar component were constructed. In the superior and inferior models, the position of the patellar component translated superiorly and inferiorly, respectively, by 3mm, relative to the center model. Kinematics of the patellar component, quadriceps force, and patellofemoral contact force were calculated using a computer simulation during a squatting activity in a weight-bearing deep knee bend. In the inferior model, the flexion angle, relative to the tibial component, was the greatest among all models. The inferior model showed an 18.0%, 36.5%, and 22.7% increase in the maximum quadriceps force, the maximum medial patellofemoral force, and the maximum lateral patellofemoral force, respectively, compared with the superior model. Superior-inferior positions affected patellofemoral kinematic and kinetics. Surgeons should avoid the inferior position of the patellar component, because the inferior positioned model showed greater quadriceps and patellofemoral force, resulting in a potential risk for anterior knee pain and component loosening. Copyright © 2017. Published by Elsevier Ltd.

  12. Previously identified patellar tendinopathy risk factors differ between elite and sub-elite volleyball players.

    PubMed

    Janssen, I; Steele, J R; Munro, B J; Brown, N A T

    2015-06-01

    Patellar tendinopathy is the most common knee injury incurred in volleyball, with its prevalence in elite athletes more than three times that of their sub-elite counterparts. The purpose of this study was to determine whether patellar tendinopathy risk factors differed between elite and sub-elite male volleyball players. Nine elite and nine sub-elite male volleyball players performed a lateral stop-jump block movement. Maximum vertical jump, training history, muscle extensibility and strength, three-dimensional landing kinematics (250 Hz), along with lower limb neuromuscular activation patterns (1500 Hz), and patellar tendon loading were collected during each trial. Multivariate analyses of variance (P < 0.05) assessed for between-group differences in risk factors or patellar tendon loading. Significant interaction effects were further evaluated using post-hoc univariate analysis of variance tests. Landing kinematics, neuromuscular activation patterns, patellar tendon loading, and most of the previously identified risk factors did not differ between the elite and sub-elite players. However, elite players participated in a higher training volume and had less quadriceps extensibility than sub-elite players. Therefore, high training volume is likely the primary contributor to the injury discrepancy between elite and sub-elite volleyball players. Interventions designed to reduce landing frequency and improve quadriceps extensibility are recommended to reduce patellar tendinopathy prevalence in volleyball players. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Treatment of Patellar Lower Pole Fracture with Modified Titanium Cable Tension Band Plus Patellar Tibial Tunnel Steel "8" Reduction Band.

    PubMed

    Li, Jiaming; Wang, Decheng; He, Zhiliang; Shi, Hao

    2018-01-08

    To determine the efficacy of modified titanium tension band plus patellar tendon tunnel steel 8 "reduction band" versus titanium cable tension band fixation for the treatment of patellar lower pole fracture. 58 patients with lower patella fracture were enrolled in this study, including 30 patients treated with modified titanium cable tension band plus patellar tibial tunnel wire "8" tension band internal fixation (modified group), and 28 patients with titanium cable tension band fixation. All patients were followed up for 9∼15 months with an average of 11.6 months. Knee flexion was significantly improved in the modified group than in the titanium cable tension band group (111.33 ± 13 degrees versus 98.21 ± 21.70 degrees, P = 0.004). The fracture healing time showed no significant difference. At the end of the follow-up, the improvement excellent rate was 93.33% in the modified group, and 82.14% in the titanium cable tension band group. Titanium cable tension band internal fixation loosening was found in 2 cases, including 1 case of treatment by two surgeries without loose internal fixation. The modified titanium cable tension band with "8" tension band fixation showed better efficacy for lower patella fractures than titanium cable tension band fixation.

  14. Patellar taping, patellofemoral pain syndrome, lower extremity kinematics, and dynamic postural control.

    PubMed

    Aminaka, Naoko; Gribble, Phillip A

    2008-01-01

    Patellar taping has been a part of intervention for treatment of patellofemoral pain syndrome (PFPS). However, research on the efficacy of patellar taping on lower extremity kinematics and dynamic postural control is limited. To evaluate the effects of patellar taping on sagittal-plane hip and knee kinematics, reach distance, and perceived pain level during the Star Excursion Balance Test (SEBT) in individuals with and without PFPS. Repeated-measures design with 2 within-subjects factors and 1 between-subjects factor. The University of Toledo Athletic Training Research Laboratory. Twenty participants with PFPS and 20 healthy participants between the ages of 18 and 29 years. The participants performed 3 reaches of the SEBT in the anterior direction under tape and no-tape conditions on both legs. The participants' hip and knee sagittal-plane kinematics were measured using the electromagnetic tracking system. Reach distance was recorded by hand and was normalized by dividing the distance by the participants' leg length (%MAXD). After each taping condition on each leg, the participants rated the perceived pain level using the 10-cm visual analog scale. The participants with PFPS had a reduction in pain level with patellar tape application compared with the no-tape condition (P = .005). Additionally, participants with PFPS demonstrated increased %MAXD under the tape condition compared with the no-tape condition, whereas the healthy participants demonstrated decreased %MAXD with tape versus no tape (P = .028). No statistically significant differences were noted in hip flexion and knee flexion angles. Although patellar taping seemed to reduce pain and improve SEBT performance of participants with PFPS, the exact mechanisms of these phenomena cannot be explained in this study. Further research is warranted to investigate the effect of patellar taping on neuromuscular control during dynamic postural control.

  15. [CLINICAL APPLICATION OF OXFORD MOBILE-BEARING BIPOLAR PROSTHESIS UNICOMPARTMENTAL KNEE ARTHROPLASTY FOR SINGLE COMPARTMENTAL KNEE OSTEOARTHRITIS].

    PubMed

    Wang, Shangzeng; Cheng, Shao; Wang, Yisheng

    2016-01-01

    To evaluate the effectiveness of Oxford mobile-bearing bipolar prosthesis unicompartmental knee arthroplasty (UKA) in the treatment of single compartmental knee osteoarthritis. Between June 2011 and July 2013, 22 cases of single compartmental knee osteoarthritis were treated by Oxford mobile-bearing bipolar prosthesis UKA. Of 22 cases, 8 were male and 14 were female with an average age of 65 years (range, 45-80 years); the left knee was involved in 12 cases, and the right knee in 10 cases, with a mean disease duration of 32.5 months (range, 8-90 months). The mean weight was 55.2 kg (range, 50-65 kg), and the mean body mass index was 20.8 kg/m2 (range, 17-25 kg/m2). Osteoarthritis involved in the single knee medial compartment in all patients. Knee society score (KSS) and range of motion (ROM) were measured to evaluate the knee joint function. Primary healing of incision was obtained in all patients, and there was no complication of infection, bedsore, or deep venous thrombosis. Postoperative follow-up was 2-4 years (mean, 3.2 years). The X-ray films showed good position of prosthesis, no prosthesis dislocation, or periprosthetic infection during follow-up. Knee ROM, KSS function score, and KSS clinical score were significantly improved at 1 week after operation and at last follow-up when compared with preoperative ones (P < 0.05), but no significant difference was shown between at 1 week and at last follow-up (P > 0.05). Oxford mobile-bearing bipolar prosthesis UKA is an effective method to treat single compartmental knee osteoarthritis, with the advantages of less trauma, earlier rehabilitation exercise, near physiological state in joint function, and less risk of complications.

  16. Validity and reliability of the Dutch translation of the VISA-P questionnaire for patellar tendinopathy.

    PubMed

    Zwerver, Johannes; Kramer, Tamara; van den Akker-Scheek, Inge

    2009-08-11

    The VISA-P questionnaire evaluates severity of symptoms, knee function and ability to play sports in athletes with patellar tendinopathy. This English-language self-administered brief patient outcome score was developed in Australia to monitor rehabilitation and to evaluate outcome of clinical studies. Aim of this study was to translate the questionnaire into Dutch and to study the reliability and validity of the Dutch version of the VISA-P. The questionnaire was translated into Dutch according to internationally recommended guidelines. Test-retest reliability was determined in 99 students with a time interval of 2.5 weeks. To determine discriminative validity of the Dutch VISA-P, 18 healthy students, 15 competitive volleyball players (at-risk population), 14 patients with patellar tendinopathy, 6 patients who had surgery for patellar tendinopathy, 17 patients with knee injuries other than patellar tendinopathy, and 9 patients with symptoms unrelated to their knees completed the Dutch VISA-P. The Dutch VISA-P questionnaire showed satisfactory test-retest reliability (ICC=0.74). The mean (+/-SD) VISA-P scores were 95 (+/-9) for the healthy students, 89 (+/-11) for the volleyball players, 58 (+/-19) for patients with patellar tendinopathy, and 56 (+/-21) for athletes who had surgery for patellar tendinopathy. Patients with other knee injuries or symptoms unrelated to the knee scored 62 (+/-24) and 77 (+/-24). The translated Dutch version of the VISA-P questionnaire is equivalent to its original version, has satisfactory test-retest reliability and is a valid score to evaluate symptoms, knee function and ability to play sports of Dutch athletes with patellar tendinopathy.

  17. Impact of Patellar Tendinopathy on Knee Proprioception: A Cross-Sectional Study.

    PubMed

    Torres, Rui; Ferreira, João; Silva, Diogo; Rodrigues, Elisa; Bessa, Isabel M; Ribeiro, Fernando

    2017-01-01

    To determine whether high-level athletes with patellar tendinopathy have diminished knee proprioceptive acuity. Cross-sectional study. University research laboratory (institutional). Twenty-one basketball and volleyball players with patellar tendinopathy (13 men and 8 women; mean age 24.5 ± 3.6; body mass index = 22.5 ± 2.0 kg/m) and an equal number of athletes without symptoms of patellar tendinopathy injury were included in this study. Participants underwent knee proprioception assessments on a single day. Furthermore, age, sex, height, weight, VISA-P (Victorian Institute of Sport Assessment) questionnaire sports participation, medical history, knee injuries, previous treatment, and medication were obtained. Knee proprioception was evaluated by assessing sense of resistance, using a weight discrimination protocol, and joint position sense (JPS). No significant differences were observed in JPS at 30 and 60 degrees of knee flexion between groups (P = 0.165 and 0.481, respectively). In regard to the ability to discriminate weight, significant differences between the 2 groups were found with the tendinopathy group showing a higher percentage of error (P = 0.009), namely when the set of incremental weights varied by 10% from the standard weight. Athletes with patellar tendinopathy have a diminished perception of force signals required for weight discrimination, whereas JPS remains unaffected in these athletes.

  18. Patient Needs for an Ambulant Dislocation Alert System Following Total Hip Arthroplasty.

    PubMed

    Huis In't Veld, Rianne; Peters, Anil; Vollenbroek-Hutten, Miriam; Hermens, Hermie; van den Hoven, Carmen

    2018-05-01

    One of the major complications in total hip arthroplasty (THA) is dislocation of the prosthesis. To prevent early dislocation, patients are instructed with movement restrictions. The first goal in this development is to obtain insight in the movement restrictions that are reported to have low levels of self-efficacy during activities of daily life. The second goal is to reveal the design needs for an ambulant hip dislocation alert system (HipDas) and the third goal is to explore its usability among patients. Patient-centered experiences with THA were explored by the use of a questionnaire and a semistructured focus group. The questionnaire was administered among n = 32 THA patients at 1 week preoperative and at 3 and 6 weeks postoperative. The questions addressed self-efficacy, performance and effort expectancy, and usefulness and social influence. The focus group consisted of patient journeys and scenario composition. The usability of a prototype version of the HipDas system was evaluated (n = 5). Flexion of the hip >90°, bending over while sitting in a chair, and sleeping in a supine position are the restrictions that have the lowest self-efficacy. The majority of patients (>86.6%) believe that a future HipDas is useful. Focus group outcomes suggest there is a gradual decrease in the threshold for feedback. The system is preferably used in the first 6 weeks after surgery and appeared to be usable and highly clinically relevant. HipDas is considered an interesting concept that can accelerate functional recovery of patients following THA by providing support on how to properly apply postoperative movement restrictions to prevent a dislocation.

  19. Achilles and patellar tendinopathy display opposite changes in elastic properties: A shear wave elastography study.

    PubMed

    Coombes, B K; Tucker, K; Vicenzino, B; Vuvan, V; Mellor, R; Heales, L; Nordez, A; Hug, F

    2018-03-01

    To compare tendon elastic and structural properties of healthy individuals with those with Achilles or patellar tendinopathy. Sixty-seven participants (22 Achilles tendinopathy, 17 patellar tendinopathy, and 28 healthy controls) were recruited between March 2015 and March 2016. Shear wave velocity (SWV), an index of tissue elastic modulus, and tendon thickness were measured bilaterally at mid-tendon and insertional regions of Achilles and patellar tendons by an examiner blinded to group. Analysis of covariance, adjusted for age, body mass index, and sex was used to compare differences in tendon thickness and SWV between the two tendinopathy groups (relative to controls) and regions. Tendon thickness was included as a covariate for analysis of SWV. Compared to controls, participants with Achilles tendinopathy had lower SWV at the distal insertion (Mean difference MD; 95% CI: -1.56; -2.49 to -0.62 m/s; P < .001) and greater thickness at the mid-tendon (MD 0.19; 0.05-0.33 cm; P = .007). Compared to controls, participants with patellar tendinopathy had higher SWV at both regions (MD 1.25; 0.40-2.10 m/s; P = .005) and greater thickness proximally (MD 0.17; 0.06-0.29 cm; P = .003). Compared to controls, participants with Achilles and patellar tendinopathy displayed lower Achilles tendon elastic modulus and higher patellar tendon elastic modulus, respectively. More research is needed to explore whether maturation, aging, or chronic load underlie these findings and whether current management programs for Achilles and patellar tendinopathy need to be tailored to the tendon. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Patellar denervation with electrocautery in total knee arthroplasty without patellar resurfacing: a meta-analysis.

    PubMed

    Cheng, Tao; Zhu, Chen; Guo, Yongyuan; Shi, Sifeng; Chen, Desheng; Zhang, Xianlong

    2014-11-01

    The impact of patellar denervation with electrocautery in total knee arthroplasty (TKA) on post-operative outcomes has been under debate. This study aims to conduct a meta-analysis and systematic review to compare the benefits and risks of circumpatellar electrocautery with those of non-electrocautery in primary TKAs. Comparative and randomized clinical studies were identified by conducting an electronic search of articles dated up to September 2012 in PubMed, EMBASE, Scopus, and the Cochrane databases. Six studies that focus on a total of 849 knees were analysed. A random-effects model was conducted using the inverse-variance method for continuous variables and the Mantel-Haenszel method for dichotomous variables. There was no significant difference in the incidence of anterior knee pain between the electrocautery and non-electrocautery groups. In term of patellar score and Knee Society Score, circumpatellar electrocautery improved clinical outcomes compared with non-electrocautery in TKAs. The statistical differences were in favour of the electrocautery group but have minimal clinical significance. In addition, the overall complications indicate no statistical significance between the two groups. This study shows no strong evidence either for or against electrocautery compared with non-electrocautery in TKAs. Therapeutic study (systematic review and meta-analysis), Level III.

  1. Dislocation

    MedlinePlus

    ... Dislocations can occur in contact sports, such as football and hockey, and in sports in which falls ... downhill skiing, gymnastics and volleyball. Basketball players and football players also commonly dislocate joints in their fingers ...

  2. In-vivo patellar tracking in individuals with patellofemoral pain and healthy individuals.

    PubMed

    Esfandiarpour, Fateme; Lebrun, Constance M; Dhillon, Sukhvinder; Boulanger, Pierre

    2018-02-28

    Understanding of the exact cause of patellofemoral pain has been limited by methodological challenges to evaluate in-vivo joint motion. This study compared six degree-of-freedom patellar motion during a dynamic lunge task between individuals with patellofemoral pain and healthy individuals. Knee joints of eight females with patellofemoral pain and ten healthy females were imaged using a CT scanner in supine lying position, then by a dual-orthogonal fluoroscope while they performed a lunge. To quantify patellar motion, the three-dimensional models of the knee bones, reconstructed from CT scans, were registered on the fluoroscopy images using the Fluomotion registration software. At full knee extension, the patella was in a significantly laterally tilted (PFP: 11.77° ± 7.58° vs. healthy: 0.86° ± 4.90°; p = 0.002) and superiorly shifted (PFP: 17.49 ± 8.44 mm vs. healthy: 9.47 ± 6.16 mm, p = 0. 033) position in the patellofemoral pain group compared with the healthy group. There were also significant differences between the groups for patellar tilt at 45°, 60°, and 75° of knee flexion, and for superior-inferior shift of the patella at 30° flexion (p ≤ 0.031). In the non-weight-bearing knee extended position, the patella was in a significantly laterally tilted position in the patellofemoral pain group (7.44° ± 6.53°) compared with the healthy group (0.71° ± 4.99°). These findings suggest the critical role of passive and active patellar stabilizers as potential causative factors for patellar malalignment/maltracking. Future studies should investigate the associations between patellar kinematics with joint morphology, muscle activity, and tendon function in a same sample for a thorough understanding of the causes of patellofemoral pain. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  3. Initial dislocation structure and dynamic dislocation multiplication in Mo single crystals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hsiung, L M; Lassila, D H

    Initial dislocation structure in annealed high-purity Mo single crystals and deformation substructure in a crystal subjected to 1% compression have been examined and studied in order to investigate dislocation multiplication mechanisms in the early stages of plastic deformation. The initial dislocation density is in a range of 10{sup 6} {approx} 10{sup 7} cm{sup -2}, and the dislocation structure is found to contain many grown-in superjogs along dislocation lines. The dislocation density increases to a range of 10{sup 8} {approx} 10{sup 9} cm{sup -2}, and the average jog height is also found to increase after compressing for a total strain ofmore » 1%. It is proposed that the preexisting jogged screw dislocations can act as (multiple) dislocation multiplication sources when deformed under quasi-static conditions. Both the jog height and length of link segment (between jogs) can increase by stress-induced jog coalescence, which takes place via the lateral migration (drift) of superjogs driven by unbalanced line-tension partials acting on link segments of unequal lengths. Applied shear stress begins to push each link segment to precede dislocation multiplication when link length and jog height are greater than critical lengths. This dynamic dislocation multiplication source is subsequently verified by direct simulations of dislocation dynamics under stress to be crucial in the early stages of plastic deformation in Mo single crystals.« less

  4. Dislocations

    MedlinePlus

    ... Things That Help Feelings Expert Answers Q&A Movies & More for Teens ... A dislocation is when two connected bones become separated. Dislocations are caused by falls and hard impacts, such as in sports injuries, and are more ...

  5. Interaction of 〈1 0 0〉 dislocation loops with dislocations studied by dislocation dynamics in α-iron

    NASA Astrophysics Data System (ADS)

    Shi, X. J.; Dupuy, L.; Devincre, B.; Terentyev, D.; Vincent, L.

    2015-05-01

    Interstitial dislocation loops with Burgers vector of 〈1 0 0〉 type are formed in α-iron under neutron or heavy ion irradiation. As the density and size of these loops increase with radiation dose and temperature, these defects are thought to play a key role in hardening and subsequent embrittlement of iron-based steels. The aim of the present work is to study the pinning strength of the loops on mobile dislocations. Prior to run massive Dislocation Dynamics (DD) simulations involving experimentally representative array of radiation defects and dislocations, the DD code and its parameterization are validated by comparing the individual loop-dislocation reactions with those obtained from direct atomistic Molecular Dynamics (MD) simulations. Several loop-dislocation reaction mechanisms are successfully reproduced as well as the values of the unpinning stress to detach mobile dislocations from the defects.

  6. Open versus closed kinetic chain exercises for patellar chondromalacia.

    PubMed

    Bakhtiary, A H; Fatemi, E

    2008-02-01

    Conservative treatment of patellar chondromalacia has been the subject of several studies. One recommended treatment is a strengthening exercise of the quadriceps muscle, which may be performed in closed or open kinetic chains. This study was designed to compare the effect of straight leg raise (SLR) and semi-squat exercises on the treatment of patellar chondromalacia, which has not been done to date. 32 female university students with a diagnosis of patellar chondromalacia were randomly assigned to two experimental groups: SLR and semi-squat exercise. Before starting exercise protocols, Q angle, maximal isometric voluntary contraction force (MIVCF) of quadriceps, crepitation, circumference of thigh 5 and 10 cm above the patella and patellofemoral pain according to the visual analogue scale (VAS) were assessed. Both groups then followed a 3-week programme of quadriceps muscle strengthening exercises (SLR or semi-squat) starting with 20 exercises twice a day and increasing each session by 5 exercises every 2 days. All measurements were repeated at the end of each week and then again 2 weeks after the 3-week exercise programme. Reduced Q angle (mean differences (SD) 0.8 (0.3), p = 0.016) and crepitation (19.9 (8.5), p = 0.04), and an increase in the MIVCF of the quadriceps (15.8 (5.6), p = 0.01) and thigh circumference (1.5 (0.3), p = 0.001) were found in semi-squat group compared with SLR group. However, patellofemoral pain was decreased significantly in both groups. The results of this study indicate that semi-squat exercises (closed kinetic chain) are more effective than SLR exercise (open kinetic chain) in the treatment of patellar chondromalacia. More studies are needed to investigate the long-term effect of these types of exercise.

  7. Is latero-medial patellar mobility related to the range of motion of the knee joint after total knee arthroplasty?

    PubMed

    Ota, Susumu; Nakashima, Takeshi; Morisaka, Ayako; Omachi, Takaaki; Ida, Kunio; Kawamura, Morio

    2010-12-01

    Diminished range of motion (ROM) of the knee joint after total knee arthroplasty (TKA) is thought to be related to reduced patellar mobility. This has not been confirmed clinically due to a lack of quantitative methods adequate for measuring patellar mobility. We investigated the relationship between patellar mobility by a reported quantitative method and knee joint ROM after TKA. Forty-nine patients [osteoarthritis--OA: 29 knees; rheumatoid arthritis--RA: 20 knees] were examined after TKA. Respective medial and lateral patellar mobility was measured 1 and 6 months postoperatively using a patellofemoral arthrometer (PFA). Knee joint ROM was also measured in each of those 2 sessions. Although the flexion and extension of the knee joints improved significantly from 1 to 6 months after TKA, the medial and lateral patellar displacements (LPDs) failed to improve during that same period. Moreover, only the changes in knee flexion and medial patellar displacement (MPD) between the two sessions were positively correlated (r = 0.31, p < 0.05). However, our findings demonstrated that medial and lateral patellar mobility had no sufficient longitudinal relationship with knee ROM after TKA. Copyright © 2010 Elsevier Ltd. All rights reserved.

  8. A soft patellar tendon on ultrasound elastography is associated with pain and functional deficit in volleyball players.

    PubMed

    Ooi, Chin Chin; Richards, Paula J; Maffulli, Nicola; Ede, David; Schneider, Michal E; Connell, David; Morrissey, Dylan; Malliaras, Peter

    2016-05-01

    To investigate the diagnostic performance of grey scale Ultrasound (US), power Doppler (PD) and US elastography for diagnosing painful patellar tendinopathy, and to establish their relationship with Victorian Institute of Sport Assessment-Patella (VISA-P) scores in a group of volleyball players with and without symptoms of patellar tendinopathy. Cross-sectional study. Thirty-five volleyball players (70 patellar tendons) were recruited during a national university volleyball competition. Players were imaged with conventional US followed by elastography. The clinical findings of painful patellar tendons were used as the reference standard for diagnosing patellar tendinopathy. In addition, all participants completed the VISA-P questionnaires. Of the 70 patellar tendons, 40 (57.1%) were clinically painful. The diagnostic accuracy of grey scale US, PD and elastography were 60%, 50%, 62.9%, respectively, with sensitivity/specificity of 72.5%/43.3%, 12.5%/100%, and 70%/53.3%, respectively. Combined US elastography and grey scale imaging achieved 82.5% sensitivity, 33.3% specificity and 61.4% accuracy while routine combination technique of PD and grey scale imaging revealed 72.5% sensitivity, 43.3% specificity and 60.0% accuracy. Tendons in players categorized as soft on elastography had statistically significantly greater AP thickness (p<0.001) and lower VISA-P scores (p=0.004) than those categorized as hard. There was no significant association between grey scale US abnormalities (hypoechogenicities and/or fusiform swelling) and VISA-P scores (p=0.098). Soft tendon properties depicted by US elastography may be more related to patellar tendon symptoms compared to grey scale US abnormalities. The supplementation of US elastography to conventional US may enhance the sensitivity for diagnosing patellar tendinopathy in routine clinical practice. Copyright © 2015 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  9. Knee isokinetic performance following anterior cruciate ligament reconstruction: patellar tendon versus hamstrings graft.

    PubMed

    Machado, Felipe; Debieux, Pedro; Kaleka, Camila Cohen; Astur, Diego; Peccin, Maria Stella; Cohen, Moisés

    2018-02-01

    To compare knee isokinetic performance six months after reconstruction of the anterior cruciate ligament using grafts from either the patellar tendon or the hamstrings among patients who underwent the same rehabilitation protocol. Thirty-four patients were evaluated (17 with grafts from the patellar tendon and 17 with grafts from the hamstrings). Operated and non-operated knees were compared with regards to the variables of peak torque, work and the hamstring/quadriceps relationship at velocities of 60º/s and 180º/s and power of 180º/s after six months of surgery. The patients with ACL reconstruction using the patellar tendon (BPTB) showed quadriceps deficits for all variables, but the flexor musculature was balanced. In the hamstring group, both the extensors and the flexors showed deficits for the variables analyzed, except for hamstring power at 180º/s. Patients in the patellar tendon group had a greater quadriceps deficit compared with those in the hamstrings group. Patients in the hamstrings group had a greater muscular deficit in the flexor mechanism compared with the contralateral knee. An unbalanced H/Q ratio was observed regardless of graft type, but this was more evident in the BPTB group.

  10. Temporomandibular joint dislocation

    PubMed Central

    Sharma, Naresh Kumar; Singh, Akhilesh Kumar; Pandey, Arun; Verma, Vishal; Singh, Shreya

    2015-01-01

    Temporomandibular joint (TMJ) dislocation is an uncommon but debilitating condition of the facial skeleton. The condition may be acute or chronic. Acute TMJ dislocation is common in clinical practice and can be managed easily with manual reduction. Chronic recurrent TMJ dislocation is a challenging situation to manage. In this article, we discuss the comprehensive review of the different treatment modalities in managing TMJ dislocation. PMID:26668447

  11. Does the adolescent patellar tendon respond to 5 days of cumulative load during a volleyball tournament?

    PubMed

    van Ark, M; Docking, S I; van den Akker-Scheek, I; Rudavsky, A; Rio, E; Zwerver, J; Cook, J L

    2016-02-01

    Patellar tendinopathy (jumper's knee) has a high prevalence in jumping athletes. Excessive load on the patellar tendon through high volumes of training and competition is an important risk factor. Structural changes in the tendon are related to a higher risk of developing patellar tendinopathy. The critical tendon load that affects tendon structure is unknown. The aim of this study was to investigate patellar tendon structure on each day of a 5-day volleyball tournament in an adolescent population (16-18 years). The right patellar tendon of 41 players in the Australian Volleyball Schools Cup was scanned with ultrasound tissue characterization (UTC) on every day of the tournament (Monday to Friday). UTC can quantify structure of a tendon into four echo types based on the stability of the echo pattern. Generalized estimating equations (GEE) were used to test for change of echo type I and II over the tournament days. Participants played between eight and nine matches during the tournament. GEE analysis showed no significant change of echo type percentages of echo type I (Wald chi-square = 4.603, d.f. = 4, P = 0.331) and echo type II (Wald chi-square = 6.070, d.f. = 4, P = 0.194) over time. This study shows that patellar tendon structure of 16-18-year-old volleyball players is not affected during 5 days of cumulative loading during a volleyball tournament. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Effect of Implanting a Soft Tissue Autograft in a Central-Third Patellar Tendon Defect: Biomechanical and Histological Comparisons

    PubMed Central

    Kinneberg, Kirsten R. C.; Galloway, Marc T.; Butler, David L.; Shearn, Jason T.

    2011-01-01

    Previous studies by our laboratory have demonstrated that implanting a stiffer tissue engineered construct at surgery is positively correlated with repair tissue stiffness at 12 weeks. The objective of this study was to test this correlation by implanting a construct that matches normal tissue biomechanical properties. To do this, we utilized a soft tissue patellar tendon autograft to repair a central-third patellar tendon defect. Patellar tendon auto-graft repairs were contrasted against an unfilled defect repaired by natural healing (NH). We hypothesized that after 12 weeks, patellar tendon autograft repairs would have biomechanical properties superior to NH. Bilateral defects were established in the central-third patellar tendon of skeletally mature (one year old), female New Zealand White rabbits (n = 10). In one limb, the excised tissue, the patellar tendon autograft, was sutured into the defect site. In the contralateral limb, the defect was left empty (natural healing). After 12 weeks of recovery, the animals were euthanized and their limbs were dedicated to bio-mechanical (n = 7) or histological (n = 3) evaluations. Only stiffness was improved by treatment with patellar tendon autograft relative to natural healing (p = 0.009). Additionally, neither the patellar tendon autograft nor natural healing repairs regenerated a normal zonal insertion site between the tendon and bone. Immunohistochemical staining for collagen type II demonstrated that fibrocartilage-like tissue was regenerated at the tendon-bone interface for both repairs. However, the tissue was disorganized. Insufficient tissue integration at the tendon-to-bone junction led to repair tissue failure at the insertion site during testing. It is important to re-establish the tendon-to-bone insertion site because it provides joint stability and enables force transmission from muscle to tendon and subsequent loading of the tendon. Without loading, tendon mechanical properties

  13. Estimation of dislocations density and distribution of dislocations during ECAP-Conform process

    NASA Astrophysics Data System (ADS)

    Derakhshan, Jaber Fakhimi; Parsa, Mohammad Habibi; Ayati, Vahid; Jafarian, Hamidreza

    2018-01-01

    Dislocation density of coarse grain aluminum AA1100 alloy (140 µm) that was severely deformed by Equal Channel Angular Pressing-Conform (ECAP-Conform) are studied at various stages of the process by electron backscattering diffraction (EBSD) method. The geometrically necessary dislocations (GNDs) density and statistically stored dislocations (SSDs) densities were estimate. Then the total dislocations densities are calculated and the dislocation distributions are presented as the contour maps. Estimated average dislocations density for annealed of about 2×1012 m-2 increases to 4×1013 m-2 at the middle of the groove (135° from the entrance), and they reach to 6.4×1013 m-2 at the end of groove just before ECAP region. Calculated average dislocations density for one pass severely deformed Al sample reached to 6.2×1014 m-2. At micrometer scale the behavior of metals especially mechanical properties largely depend on the dislocation density and dislocation distribution. So, yield stresses at different conditions were estimated based on the calculated dislocation densities. Then estimated yield stresses were compared with experimental results and good agreements were found. Although grain size of material did not clearly change, yield stress shown intensive increase due to the development of cell structure. A considerable increase in dislocations density in this process is a good justification for forming subgrains and cell structures during process which it can be reason of increasing in yield stress.

  14. Use of platelet-rich plasma for patellar tendon and medial collateral ligament injuries: best current clinical practice.

    PubMed

    Andia, Isabel; Maffulli, Nicola

    2015-02-01

    Platelet-rich plasmas (PRPs) are complex molecular therapies prepared from the patient's own blood through minimal manipulation. Clinical studies examining the efficacy of PRPs to manage patellar tendinopathy and medial collateral ligament (MCL) injuries have been reviewed. We found three controlled trials, two of them randomized, and seven case series in the management of patellar tendinopathy. In addition, three other randomized studies showed that PRPs help to regenerate the patellar tendon harvest site for anterior cruciate ligament reconstruction and to reduce patellar donor site morbidity. On the other hand, the use of PRP in MCL injuries is reported in a single case study. Seven of the 11 studies used leukocyte and PRP which was buffered in four studies. Seven of the 11 studies applied two or three injections. Given the heterogeneity of PRP protocols and the paucity of high-quality data, the most effective approach to guide clinical decisions regarding patellar tendinopathy cannot be deduced from the present published studies. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  15. Plateau-patella angle in evaluation of patellar height after total knee arthroplasty.

    PubMed

    Robin, Brett N; Ellington, Matthew D; Jupiter, Daniel C; Allen, Bryce C

    2014-07-01

    The plateau-patella angle (PPA) has been proposed as a new and simpler method to describe patellar height. This method has not been used or validated in knees following total knee arthroplasty (TKA). A modified PPA (mPPA) was developed for use in this population. The method was validated by determining the interobserver and intraobserver reliability of the technique in 50 consecutive patients compared to three well-described methods of describing patellar height after TKA. Three observers then evaluated the mPPA of 297 post-operative radiographs to describe a normal range after TKA for a given technique and implant. The interobserver reliability was the highest for the mPPA compared to the other methods. The mean mPPA for the entire cohort was 21.06, 20.49, and 19.94 for the three observers. The modified plateau-patella angle is a reliable way to evaluate patellar height in patients who have undergone total knee arthroplasty. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. Multiscale modeling of dislocation-precipitate interactions in Fe: From molecular dynamics to discrete dislocations.

    PubMed

    Lehtinen, Arttu; Granberg, Fredric; Laurson, Lasse; Nordlund, Kai; Alava, Mikko J

    2016-01-01

    The stress-driven motion of dislocations in crystalline solids, and thus the ensuing plastic deformation process, is greatly influenced by the presence or absence of various pointlike defects such as precipitates or solute atoms. These defects act as obstacles for dislocation motion and hence affect the mechanical properties of the material. Here we combine molecular dynamics studies with three-dimensional discrete dislocation dynamics simulations in order to model the interaction between different kinds of precipitates and a 1/2〈111〉{110} edge dislocation in BCC iron. We have implemented immobile spherical precipitates into the ParaDis discrete dislocation dynamics code, with the dislocations interacting with the precipitates via a Gaussian potential, generating a normal force acting on the dislocation segments. The parameters used in the discrete dislocation dynamics simulations for the precipitate potential, the dislocation mobility, shear modulus, and dislocation core energy are obtained from molecular dynamics simulations. We compare the critical stresses needed to unpin the dislocation from the precipitate in molecular dynamics and discrete dislocation dynamics simulations in order to fit the two methods together and discuss the variety of the relevant pinning and depinning mechanisms.

  17. Suture anchor repair of patellar tendon rupture after total knee arthroplasty.

    PubMed

    Kamath, Atul F; Shah, Roshan P; Summers, Nathan; Israelite, Craig L

    2013-12-01

    Extensor mechanism disruption after total knee arthroplasty (TKA) is a complex problem that often requires surgical repair for functional deficits. We present a brief technical note on suture anchor fixation of a patellar tendon rupture after TKA. A surgical technique and literature review follows. Although suture anchor fixation is well described for tendinous repairs in other areas of orthopedic surgery, no study has discussed the use of suture anchors in patellar tendon repair after TKA. The technique must be evaluated in more patients with longer follow-up before adoption. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  18. Changes in Morphological and Elastic Properties of Patellar Tendon in Athletes with Unilateral Patellar Tendinopathy and Their Relationships with Pain and Functional Disability

    PubMed Central

    Zhang, Zhi Jie; Ng, Gabriel Yin-fat; Lee, Wai Chun; Fu, Siu Ngor

    2014-01-01

    Background Patellar tendinopathy (PT) is one of the most common knee disorders among athletes. Changes in morphology and elasticity of the painful tendon and how these relate to the self-perceived pain and dysfunction remain unclear. Objectives To compare the morphology and elastic properties of patellar tendons between athlete with and without unilateral PT and to examine its association with self-perceived pain and dysfunction. Methods In this cross-sectional study, 33 male athletes (20 healthy and 13 with unilateral PT) were enrolled. The morphology and elastic properties of the patellar tendon were assessed by the grey and elastography mode of supersonic shear imaging (SSI) technique while the intensity of pressure pain, self-perceived pain and dysfunction were quantified with a 10-lb force to the most painful site and the Victorian Institute of Sport Assessment-patella (VISA-P) questionnaire, respectively. Results In athletes with unilateral PT, the painful tendons had higher shear elastic modulus (SEM) and larger tendon than the non-painful side (p<0.05) or the dominant side of the healthy athletes (p<0.05). Significant correlations were found between tendon SEM ratio (SEM of painful over non-painful tendon) and the intensity of pressure pain (rho  = 0.62; p = 0.024), VISA-P scores (rho  = −0.61; p = 0.026), and the sub-scores of the VISA-P scores on going down stairs, lunge, single leg hopping and squatting (rho ranged from −0.63 to −0.67; p<0.05). Conclusions Athletes with unilateral PT had stiffer and larger tendon on the painful side than the non-painful side and the dominant side of healthy athletes. No significant differences on the patellar tendon morphology and elastic properties were detected between the dominant and non-dominant knees of the healthy control. The ratio of the SEM of painful to non-painful sides was associated with pain and dysfunction among athletes with unilateral PT. PMID:25303466

  19. Technical note: validation of a motion analysis system for measuring the relative motion of the intermediate component of a tripolar total hip arthroplasty prosthesis.

    PubMed

    Chen, Qingshan; Lazennec, Jean Yves; Guyen, Olivier; Kinbrum, Amy; Berry, Daniel J; An, Kai-Nan

    2005-07-01

    Tripolar total hip arthroplasty (THA) prosthesis had been suggested as a method to reduce the occurrence of hip dislocation and microseparation. Precisely measuring the motion of the intermediate component in vitro would provide fundamental knowledge for understanding its mechanism. The present study validates the accuracy and repeatability of a three-dimensional motion analysis system to quantitatively measure the relative motion of the intermediate component of tripolar total hip arthroplasty prostheses. Static and dynamic validations of the system were made by comparing the measurement to that of a potentiometer. Differences between the mean system-calculated angle and the angle measured by the potentiometer were within +/-1 degrees . The mean within-trial variability was less than 1 degrees . The mean slope was 0.9-1.02 for different angular velocities. The dynamic noise was within 1 degrees . The system was then applied to measure the relative motion of an eccentric THA prosthesis. The study shows that this motion analysis system provides an accurate and practical method for measuring the relative motion of the tripolar THA prosthesis in vitro, a necessary first step towards the understanding of its in vivo kinematics.

  20. BIORESORBABLE POLYMERIC MENISCAL PROSTHESIS: STUDY IN RABBITS

    PubMed Central

    Cardoso, Tulio Pereira; de Rezende Duek, Eliana Aparecida; Amatuzzi, Marco Martins; Caetano, Edie Benedito

    2015-01-01

    Objective: To induce growth of a neomeniscus into the pores of a prosthesis in order to protect the knee joint cartilage. Methods: 70 knees of 35 New Zealand rabbits were operated. The rabbits were five to seven months old, weighed 2 to 3.8 kilograms, and 22 were male and 13 were female. Each animal underwent medial meniscectomy in both knees during a single operation. A bioabsorbable polymeric meniscal prosthesis composed of 70% polydioxanone and 30% L-lactic acid polymer was implanted in one side. The animals were sacrificed after different postoperative time intervals. The femoral condyles and neomeniscus were subjected to histological analysis. Histograms were used to measure the degradation and absorption of the prosthesis, the growth of meniscal tissue in the prosthesis and the degree of degradation of the femoral condyle joint cartilage. Results: The data obtained showed that tissue growth histologically resembling a normal meniscus occurred, with gradual absorption of the prosthesis, and the percentages of chondrocytes on the control side and prosthesis side. Conclusion: Tissue growth into the prosthesis pores that histologically resembled the normal rabbit meniscus was observed. The joint cartilage of the femoral condyles on the prosthesis side presented greater numbers of chondrocytes in all its layers. PMID:27022549

  1. The Effect of Diacutaneous Fibrolysis on Patellar Position Measured Using Ultrasound Scanning in Patellofemoral Pain Syndrome Patients.

    PubMed

    Fanlo-Mazas, Pablo; Bueno-Gracia, Elena; de Escudero-Zapico, Alazne Ruiz; Tricás-Moreno, José Miguel; Lucha-López, María Orosia

    2018-04-13

    Tightness or lack of flexibility of flexibility of several muscles of the thigh has been associated with patellofemoral-join pain. A tight iliotibial band can lead to laterally located patella and an abnormal patellar tracking pattern. Diacutaneous fibrolysis is commonly used to reduce muscle tightness, but no studies have evaluated the effects of this technique in the treatment of patellofemoral pain syndrome patients. To assess the effect of diacutaneous fibrolysis on patellar position in patients with patellofemoral pain syndrome. A single-group, pretest-posttest clinical trial. University of Zaragoza. 46 subjects with patellofemoral pain (20 males, 26 females (age 27.8 ± 6.9 years)). 3 sessions of diacutaneous fibrolysis. Patellar position measurement using real time ultrasound scanning, pain intensity measured with visual analogue scale and function measured with the Anterior Knee Pain Scale. The application of three sessions of diacutaneous fibrolysis significantly increased the patellar position at post-treatment evaluation (p<0.001) and at one-week follow-up (p<0.001). There was not a significance difference on patellar position between post-treatment and follow-up measurements (p=0.283). There were also a statistically significant decrease in pain and increase in function at post-treatment and at one-week follow-up measurements (p<0.001). This study found that patellar position, pain intensity and function were significantly improved after three sessions of diacutaneous fibrolysis and at one week follow up.

  2. Prosthesis for blepharospasm.

    PubMed

    Moss, H L

    1983-12-01

    Following several years of experience with a newly designed spectacle-supported ptosis crutch for ptosis and blepharospasm, the author has developed a new approach to these conditions. In mild to moderate blepharospasm cases, the spectacle-supported prosthesis can still produce satisfactory results. However, in moderate to severe blepharospasm, the force of the spasm moves the entire device forward and downward, making it ineffective or too uncomfortable to wear. To create greater stability and a more effective counterforce to the blepharospasm, the author has developed a simple headband-supported device which does not use a spectacle frame for support. This new prosthesis is constructed of varying diameters of spring tempered diamond drawn stainless steel orthodontic wire, partially or completely covered by Teflon tubing. A silicon rubber cylinder is placed over the center which becomes a bridge and the main support for the device. An elastic head band completes the prosthesis.

  3. Permanent Quadriplegia Following Replacement of Voice Prosthesis.

    PubMed

    Ozturk, Kayhan; Erdur, Omer; Kibar, Ertugrul

    2016-11-01

    The authors presented a patient with quadriplegia caused by cervical spine abscess following voice prosthesis replacement. The authors present the first reported permanent quadriplegia patient caused by voice prosthesis replacement. The authors wanted to emphasize that life-threatening complications may be faced during the replacement of voice prosthesis. Care should be taken during the replacement of voice prosthesis and if some problems have been faced during the procedure patients must be followed closely.

  4. Laser-assisted fixation of a nitinol stapes prosthesis.

    PubMed

    Schrötzlmair, Florian; Suchan, Fabian; Pongratz, Thomas; Krause, Eike; Müller, Joachim; Sroka, Ronald

    2018-02-01

    Otosclerosis is an inner ear bone disease characterized by fixation of the stapes and consequently progressive hearing loss. One treatment option is the surgical replacement of the stapes by a prosthesis. When so called "smart materials" like nitinol are used, prosthesis fixation can be performed using a laser without manual crimping on the incus. However, specific laser-prosthesis interactions have not been described yet. The aim of the present study was to elucidate the thermo-mechanical properties of the NiTiBOND® prosthesis as a basis for handling instructions for laser-assisted prosthesis fixation. Closure of the NiTiBOND® prosthesis was induced ex vivo by either a diode laser emitting at λ = 940 nm or a CO 2 laser (λ = 10,600 nm). Total energy for closure was determined. Suitable laser parameters (pulse duration, power per pulse, distance between tip of the laser fiber and prosthesis) were assessed. Specific laser-prosthesis interactions were recorded. Especially the diode laser was found to be an appropriate energy source. A total energy deposit of 60 mJ by pulses in near contact application was found to be sufficient for prosthesis closure ex vivo. Energy should be transmitted through a laser fiber equipollent to the prosthesis band diameter. Specific deformation characteristics due to the zonal prosthesis composition have to be taken into account. NiTiBOND® stapes prosthesis can be closed by very little energy when appropriate energy sources like diode lasers are used, suggesting a relatively safe application in vivo. Lasers Surg. Med. 50:153-157, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  5. Diagnostic Accuracy of a Self-Report Measure of Patellar Tendinopathy in Youth Basketball.

    PubMed

    Owoeye, Oluwatoyosi B A; Wiley, J Preston; Walker, Richard E A; Palacios-Derflingher, Luz; Emery, Carolyn A

    2018-04-27

    Study Design Prospective diagnostic accuracy validation study. Background Engaging clinicians for diagnosis of patellar tendinopathy in large surveillance studies is often impracticable. A self-report measure, the Oslo Sports Research Trauma Centre patellar tendinopathy (OSTRC-P) Questionnaire, an adaptation of the OSTRC Questionnaire may provide a viable alternative. Objectives To evaluate the diagnostic accuracy of the OSTRC-P Questionnaire in detecting patellar tendinopathy in youth basketball players when compared to clinical evaluation. Methods Following the Standards for Reporting of Diagnostic Accuracy Studies guidelines, 208 youth basketball players (aged 13-18 years) were recruited. Participants completed the OSTRC-P Questionnaire (index test) prior to a clinical evaluation (reference standard) by a physiotherapist blinded to OSTRC-P Questionnaire results. Sensitivity, specificity, predictive values (PVs), likelihood ratios (LRs) and posttest probabilities were calculated. Linear regression was used to examine the association between OSTRC-P Questionnaire severity score and patellar tendinopathy severity rating during single leg decline squat (SLDS). Results The final analysis included 169 players. The OSTRC-P Questionnaire had a sensitivity of 79% (95%CI: 65%, 90%), specificity of 98% (95%CI: 94%, 100%), positive PV of 95%, negative PV of 92%, positive LR of 48 and negative LR of 0.21. The posttest probabilities were 95% and 8% given positive and negative results, respectively. A positive association was found between OSTRC-P Questionnaire and SLDS rating [(β = .08 (95%CI: .03, .12) (p = .001)]. Conclusions The OSTRC-P Questionnaire is an acceptable alternative to clinical evaluation for self-reporting patellar tendinopathy and grading its severity in settings involving youth basketball players. Level of Evidence Diagnosis, level 1b. J Orthop Sports Phys Ther, Epub 27 Apr 2018. doi:10.2519/jospt.2018.8088.

  6. The Relationship of Static Tibial Tubercle-Trochlear Groove Measurement and Dynamic Patellar Tracking.

    PubMed

    Carlson, Victor R; Sheehan, Frances T; Shen, Aricia; Yao, Lawrence; Jackson, Jennifer N; Boden, Barry P

    2017-07-01

    The tibial tubercle to trochlear groove (TT-TG) distance is used for screening patients with a variety of patellofemoral joint disorders to determine who may benefit from patellar medialization using a tibial tubercle osteotomy. Clinically, the TT-TG distance is predominately based on static imaging with the knee in full extension; however, the predictive ability of this measure for dynamic patellar tracking patterns is unknown. To determine whether the static TT-TG distance can predict dynamic lateral displacement of the patella. Cohort study (Diagnosis); Level of evidence, 2. The static TT-TG distance was measured at full extension for 70 skeletally mature subjects with (n = 32) and without (n = 38) patellofemoral pain. The dynamic patellar tracking patterns were assessed from approximately 45° to 0° of knee flexion by use of dynamic cine-phase contrast magnetic resonance imaging. For each subject, the value of dynamic lateral tracking corresponding to the exact knee angle measured in the static images for that subject was identified. Linear regression analysis determined the predictive ability of static TT-TG distance for dynamic patellar lateral displacement for each cohort. The static TT-TG distance measured with the knee in full extension cannot accurately predict dynamic lateral displacement of the patella. There was weak predictive ability among subjects with patellofemoral pain ( r 2 = 0.18, P = .02) and no predictive capability among controls. Among subjects with patellofemoral pain and static TT-TG distances 15 mm or more, 8 of 13 subjects (62%) demonstrated neutral or medial patellar tracking patterns. The static TT-TG distance cannot accurately predict dynamic lateral displacement of the patella. A large percentage of patients with patellofemoral pain and pathologically large TT-TG distances may have neutral to medial maltracking patterns.

  7. Greater glycosaminoglycan content in human patellar tendon biopsies is associated with more pain and a lower VISA score.

    PubMed

    Attia, Mohamed; Scott, Alexander; Carpentier, Gilles; Lian, Oystein; Van Kuppevelt, Toin; Gossard, Camille; Papy-Garcia, Dulce; Tassoni, Marie-Claude; Martelly, Isabelle

    2014-03-01

    People with patellar tendinopathy experience chronic pain and activity limitation, but a pertinent biochemical marker correlated with these clinical features has not been identified. The Victoria Institute of Sport Assessment (VISA) questionnaire is a condition-specific patient-rated outcome measure. Since the quantity of glycosaminoglycans (GAGs) increases with advancing tendon pathology, we hypothesised that there would be a correlation between the quantity of GAGs in the patellar tendon and the VISA score. Tissue biopsies from athletes with chronic patellar tendinopathy (confirmed by clinical examination and MRI) were recruited (n=7), as well as controls with no history of knee pain (n=4). The quantity of sulphated GAGs in the human patellar tendons was determined with a dimethyl methylene blue (DMMB) assay; this method was first validated with rat tendon tissue. The extent and distribution of GAG species and proteoglycans (decorin, versican and aggrecan) in the human tendon biopsies were examined using immunohistochemistry. Greater sulphated GAG content of the patellar tendon was correlated with the greater tendon dysfunction (R(2)=0.798). The quantity of aggrecan in the tendon, a chondroitin sulphate-rich proteoglycan, also increased with advancing tendon pathology. Increased GAGs in the pathological human patellar tendon are related to a worse clinical status. These findings indicate that the VISA score reflects the extent of tendon tissue pathology.

  8. COMPARISON OF FUNCTIONAL ACTIVITIES ON STRUCTURAL CHANGES OF THE INFERIOR PATELLAR POLE

    PubMed Central

    Wallmann, Harvey; Stalcup, Patrick; DiTommaso, Katie

    2017-01-01

    Background It is well known that eccentric and concentric exercise produce varied amounts of stress on the connective tissues. Diagnostic ultrasound has been used to measure these structural changes by observing fascicle length, angle, and thickness; however, there is a lack of evidence comparing the structural changes as it relates to eccentric, concentric, and stretching protocols. Purpose The purpose of this study was to compare the acute effects of static stretching, eccentric, concentric, and a combination of eccentric/concentric exercises on structural changes of the muscle tendon unit at the inferior patellar pole utilizing the diagnostic ultrasound. Study Design A repeated measures 2 × 4 within factorial study design with repeated measures on both factors was used to determine the differences in patellar tendon thickness within and between groups. Methods Forty-seven healthy subjects were screened for any lower extremity deficits or orthopaedic pathology. Forty-four (N=44) subjects completed all four protocols; the attrition was due to injuries to the lower extremity, occurring unrelated to the study. A baseline measurement of the anterior inferior patellar tendon was performed with the diagnostic ultrasound prior to each participant completing one of the four interventions per week over a four-week period. Interventions completed by each participant included static stretching, concentric, eccentric, and combined concentric and eccentric exercises. Immediately following each intervention, a post-intervention inferior patellar tendon measurement was recorded using the diagnostic ultrasound. Results Significant differences in anterior to posterior tendon thickness of the inferior patellar tendon were observed between pre (4.983 ± 0.041mm) and post (5.198 ± 0.055mm) measurements (p<0.0005) for the main effect of time. However, no differences in tendon thickness were noted comparing each intervention to one another (p=0.351). Conclusion Differences

  9. Dislocation-induced stress in polycrystalline materials: mesoscopic simulations in the dislocation density formalism

    NASA Astrophysics Data System (ADS)

    Berkov, D. V.; Gorn, N. L.

    2018-06-01

    In this paper we present a simple and effective numerical method which allows a fast Fourier transformation-based evaluation of stress generated by dislocations with arbitrary directions and Burgers vectors if the (site-dependent) dislocation density is known. Our method allows the evaluation of the dislocation stress using a rectangular grid with shape-anisotropic discretization cells without employing higher multipole moments of the dislocation interaction coefficients. Using the proposed method, we first simulate the stress created by relatively simple non-homogeneous distributions of vertical edge and so-called ‘mixed’ dislocations in a disk-shaped sample, which is necessary to understand the dislocation behavior in more complicated systems. The main part of our research is devoted to the stress distribution in polycrystalline layers with the dislocation density rapidly varying with the distance to the layer bottom. Considering GaN as a typical example of such systems, we investigate dislocation-induced stress for edge and mixed dislocations, having random orientations of Burgers vectors among crystal grains. We show that the rapid decay of the dislocation density leads to many highly non-trivial features of the stress distributions in such layers and study in detail the dependence of these features on the average grain size. Finally we develop an analytical approach which allows us to predict the evolution of the stress variance with the grain size and compare analytical predictions with numerical results.

  10. In vitro kinematic measurements of the patellar tendon in two different types of posterior-stabilized total knee arthroplasties.

    PubMed

    Zhu, Zhonglin; Ding, Hui; Dang, Xiao; Tang, Jing; Zhou, Yixin; Wang, Guangzhi

    2010-01-01

    Fixed-bearing posterior-stabilized (PS) total knee arthroplasty (TKA) has been used in Asian countries for several years, but few studies have investigated differences in the kinematic properties of the patellar tendon after standard PS TKA as compared to high-flex PS TKA. To quantify the in vitro three-dimensional (3D) kinematics of the patellar tendon during passive high flexion and full extension before and after two different types of PS TKAs. Six fresh-frozen cadaveric knees were tested under the following conditions: the unaltered state, status-post traditional PS prostheses (Simth-nephew GENESIS II) replacement, and status-post high-flexion PS prostheses replacement. The soft tissue around the knee and the quadriceps muscle were preserved, then tested under the load of a specific weight in an Oxford knee rig. We designed a specialized rigid body with four active markers fixed to each bone to track the 3D passive motion of the cadaveric knees. Flexion and extension was controlled by the knee rig and captured by an Optotrak Certus high precision optical tracking system. The attachment sites of the patellar tendon were registered as virtual markers to calculate the 3D kinematics. The patellar tendon of the unaltered knee and both TKA knees showed similar deformation. We found the length of the patellar tendon changed significantly during a motion from full extension to 30°, but there was no significant change in length while undergoing a motion from 30° to full flexion. Both the sagittal plane and coronal plane angles of the patellar tendon decreased after PS TKAs. There was no significant difference in patellar tendon kinematics between the two types of PS TKAs. We believe the changes observed in the sagittal plane and coronal plane angles of the patellar tendon after PS TKAs may influence the extensor mechanism and be an important cause of patella-femoral complications. These data may be used to assess patella-femoral complications after surgery so as to

  11. Reverse Shoulder Arthroplasty Prosthesis Design Classification System.

    PubMed

    Routman, Howard D; Flurin, Pierre-Henri; Wright, Thomas W; Zuckerman, Joseph D; Hamilton, Matthew A; Roche, Christopher P

    2015-12-01

    Multiple different reverse total shoulder arthroplasty (rTSA) prosthesis designs are available in the global marketplace for surgeons to perform this growing procedure. Subtle differences in rTSA prosthesis design parameters have been shown to have significant biomechanical impact and clinical consequences. We propose an rTSA prosthesis design classification system to objectively identify and categorize different designs based upon their specific glenoid and humeral prosthetic characteristics for the purpose of standardizing nomenclature that will help the orthopaedic surgeon determine which combination of design configurations best suit a given clinical scenario. The impact of each prosthesis classification type on shoulder muscle length and deltoid wrapping are also described to illustrate how each prosthesis classification type impacts these biomechanical parameters.

  12. Association between patellar cartilage defects and patellofemoral geometry: a matched-pair MRI comparison of patients with and without isolated patellar cartilage defects.

    PubMed

    Mehl, Julian; Feucht, Matthias J; Bode, Gerrit; Dovi-Akue, David; Südkamp, Norbert P; Niemeyer, Philipp

    2016-03-01

    To compare the geometry of the patellofemoral joint on magnetic resonance images (MRI) between patients with isolated cartilage defects of the patella and a gender- and age-matched control group of patients without patellar cartilage defects. A total of 43 patients (17 female, 26 male) with arthroscopically verified grade III and IV patellar cartilage defects (defect group) were compared with a matched-pair control group of patients with isolated traumatic rupture of the anterior cruciate ligament without cartilage defects of the patellofemoral joint. Preoperative MRI images were analysed retrospectively with regard to patellar geometry (width, thickness, facet angle), trochlear geometry (dysplasia according to Dejour, sulcus angle, sulcus depth, lateral condyle index, trochlea facet asymmetry, lateral trochlea inclination) and patellofemoral alignment (tibial tuberosity-trochlear groove distance, patella height, lateral patella displacement, lateral patellofemoral angle, patella tilt, congruence angle). In addition to the comparison of group values, the measured values were compared to normal values reported in the literature, and the frequency of patients with pathologic findings was compared between both groups. The defect group demonstrated a significantly higher proximal chondral sulcus angle (p < 0.001), a significantly higher distal osseal sulcus angle (p = 0.004), a significantly lower distal sulcus depth (p = 0.047), a significantly lower lateral condyle index (p = 0.045), a significantly lower Caton-Deschamps index (p = 0.020) and a significantly higher Insall-Salvati index (p = 0.010). A major trochlear dysplasia (grade B-D) was significantly more common in the defect group (54 vs. 19%; p < 0.001). Eighty-eight per cent of patients in the defect group demonstrated at least one pathologic finding, compared to 63% in the control group (p = 0.006). Two or more pathologic findings were observed in 42% of the defect group and in 19% of the control group (p

  13. Glide dislocation nucleation from dislocation nodes at semi-coherent {111} Cu–Ni interfaces

    DOE PAGES

    Shao, Shuai; Wang, Jian; Beyerlein, Irene J.; ...

    2015-07-23

    Using atomistic simulations and dislocation theory on a model system of semi-coherent {1 1 1} interfaces, we show that misfit dislocation nodes adopt multiple atomic arrangements corresponding to the creation and redistribution of excess volume at the nodes. We identified four distinctive node structures: volume-smeared nodes with (i) spiral or (ii) straight dislocation patterns, and volume-condensed nodes with (iii) triangular or (iv) hexagonal dislocation patterns. Volume-smeared nodes contain interfacial dislocations lying in the Cu–Ni interface but volume-condensed nodes contain two sets of interfacial dislocations in the two adjacent interfaces and jogs across the atomic layer between the two adjacent interfaces.more » Finally, under biaxial tension/compression applied parallel to the interface, we show that the nucleation of lattice dislocations is preferred at the nodes and is correlated with the reduction of excess volume at the nodes.« less

  14. Is it possible to re-establish pre-operative patellar kinematics using a ligament-balanced technique in total knee arthroplasty? A cadaveric investigation.

    PubMed

    Keshmiri, Armin; Springorum, Hans; Baier, Clemens; Zeman, Florian; Grifka, Joachim; Maderbacher, Günther

    2015-03-01

    Several authors emphasise that the appearance of patellar maltracking after total knee arthroplasty (TKA) is caused by rotational malalignment of the femoral and tibial components. Ligament-balanced femoral component rotation was not found to be associated with abnormal postoperative patellar position. We hypothesised that a ligament-balanced technique in TKA has the ability to best re-establish patellar kinematics. In ten cadaveric knees TKA was performed assessing femoral rotation in ligament-balanced and different femoral and tibial component rotation alignments. Patellar kinematics after different component rotations were analysed using a commercial computer navigation system. Ligament-balanced femoral rotation showed the best re-establishment of patellar kinematics after TKA compared to the healthy pre-operative knee. In contrast to tibial component rotation, femoral component rotation had a major impact on patellofemoral kinematics. This investigation suggests that a ligament-balanced technique in TKA is most likely to re-establish natural patellofemoral kinematics. Tibial component rotation did not influence patellar kinematics.

  15. Endoscopic bursectomy for the treatment of septic pre-patellar bursitis: a case series.

    PubMed

    Dillon, John P; Freedman, Ilan; Tan, James S M; Mitchell, David; English, Shaun

    2012-07-01

    Operative treatment for septic pre-patellar bursitis generally involves open debridement in addition to an extended course of intravenous antibiotics. Skin necrosis and wound breakdown are potential complications of this procedure in addition to scar sensitivity and a prolonged recovery. We report endoscopic bursectomy for the treatment of septic pre-patellar bursitis in eight patients over a 3-year period. All patients had microbiological confirmation of an infective process. The average age was 36 years (23-68 years). The average hospital stay was 6 days (4-9 days). No patient had a recurrence or complained of tenderness or hypoaesthesia around their wound. No patient experienced wound complications or skin necrosis. The average return to work time was 18 days (7-22 days). We conclude that endoscopic bursectomy is a safe and effective treatment for septic pre-patellar bursitis with a shortened hospital stay and a quicker return to work than conventional open debridement.

  16. 21 CFR 872.3960 - Mandibular condyle prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3960 Mandibular condyle prosthesis. (a) Identification. A mandibular condyle prosthesis is a device that is intended to be implanted in the human jaw to... requirement for premarket approval for any mandibular condyle prosthesis intended to be implanted in the human...

  17. Outcomes after salvage procedures for the painful dislocated hip in cerebral palsy.

    PubMed

    Wright, Patrick B; Ruder, John; Birnbaum, Mark A; Phillips, Jonathan H; Herrera-Soto, Jose A; Knapp, Dennis R

    2013-01-01

    The painful dislocated hip in the setting of cerebral palsy is a challenging problem. Many surgical procedures have been reported to treat this condition with varying success rates. The purpose of this study is to retrospectively evaluate and compare the outcomes of 3 different surgical procedures performed at our institution for pain relief in patients with spastic quadriplegic cerebral palsy and painful dislocated hips. A retrospective chart review of the surgical procedures performed by 5 surgeons for spastic, painful dislocated hips from 1997 to 2010 was performed. The procedures identified were (1) proximal femoral resection arthroplasty (PFRA); (2) subtrochanteric valgus osteotomy (SVO) with femoral head resection; and (3) proximal femur prosthetic interposition arthroplasty (PFIA) using a humeral prosthesis. Outcomes based on pain and range of motion were determined to be excellent, good, fair, or poor by predetermined criteria. Forty-four index surgeries and 14 revision surgeries in 33 patients with an average follow-up of 49 months met the inclusion criteria. Of the index surgeries, 12 hips were treated with a PFRA, 21 with a SVO, and 11 with a PFIA. An excellent or good result was noted in 67% of PFRAs, 67% of SVOs, and 73% of PFIAs. No statistical significance between these procedures was achieved. The 14 revisions were performed because of a poor result from previous surgery, demonstrating a 24% reoperation rate overall. No patients classified as having a fair result underwent revision surgery. All patients receiving revision surgery were eventually classified as having an excellent or good result. Surgical treatment for the painful, dislocated hip in the setting of spastic quadriplegic cerebral palsy remains unsettled. There continue to be a large percentage of failures despite the variety of surgical techniques designed to treat this problem. These failures can be managed, however, and eventually resulted in a good outcome. We demonstrated a trend

  18. "Conjugate channeling" effect in dislocation core diffusion: carbon transport in dislocated BCC iron.

    PubMed

    Ishii, Akio; Li, Ju; Ogata, Shigenobu

    2013-01-01

    Dislocation pipe diffusion seems to be a well-established phenomenon. Here we demonstrate an unexpected effect, that the migration of interstitials such as carbon in iron may be accelerated not in the dislocation line direction ξ, but in a conjugate diffusion direction. This accelerated random walk arises from a simple crystallographic channeling effect. c is a function of the Burgers vector b, but not ξ, thus a dislocation loop possesses the same everywhere. Using molecular dynamics and accelerated dynamics simulations, we further show that such dislocation-core-coupled carbon diffusion in iron has temperature-dependent activation enthalpy like a fragile glass. The 71° mixed dislocation is the only case in which we see straightforward pipe diffusion that does not depend on dislocation mobility.

  19. Debye screening of dislocations.

    PubMed

    Groma, I; Györgyi, G; Kocsis, B

    2006-04-28

    Debye-like screening by edge dislocations of some externally given stress is studied by means of a variational approach to coarse grained field theory. Explicitly given are the force field and the induced geometrically necessary dislocation (GND) distribution, in the special case of a single glide axis in 2D, for (i) a single edge dislocation and (ii) a dislocation wall. Numerical simulation demonstrates that the correlation in relaxed dislocation configurations is in good agreement with the induced GND in case (i). Furthermore, the result (ii) well predicts the experimentally observed decay length for the GND developing close to grain boundaries.

  20. Patellar tendinopathy in young elite soccer- clinical and sonographical analysis of a German elite soccer academy.

    PubMed

    Bode, Gerrit; Hammer, Thorsten; Karvouniaris, N; Feucht, M J; Konstantinidis, L; Südkamp, N P; Hirschmüller, A

    2017-08-08

    The prevalence of patellar tendinopathy is elevated in elite soccer compared to less explosive sports. While the burden of training hours and load is comparably high in youth elite players (age < 23 years), little is known about the prevalence of patellar tendinopathy at this age. There is only little data available on the influence of age, the amount of training, the position on the field, as well as muscular strength, range of motion, or sonographical findings in this age group. The purpose of the present study was to examine the above-mentioned parameters in all age groups of a German youth elite soccer academy. One hundred nineteen male youth soccer players (age 15,97 ± 2,24 years, height 174, 60 ± 10,16 cm, BMI 21, 24 ± 2,65) of the U-13 to U-23 teams were part of the study. Data acquisition included sport specific parameters such as footwear, amount of training hours, leg dominance, history of tendon pathologies, and clinical examination for palpatory pain, indurations, muscular circumference, and range of motion. Subjective complaints were measured with the Victorian Institute of Sport Assessment Patellar (VISA-P) Score. Furthermore, sonographical examinations (Aplio SSA-770A/80; Toshiba, Tokyo, Japan) with 12-MHz multifrequency linear transducers (8-14 MHz) of both patellar tendons were performed with special emphasis on hyper- and hypo echogenic areas, diameter and neovascularization. The prevalence of patellar tendinopathies was 13.4%. Seventy-five percent of the players complained of pain of their dominant leg with onset of pain at training in 87.5%. The injured players showed a medium amount of 10.34 ± 3.85 training hours and a medium duration of symptoms of 11.94 ± 18.75 weeks. Two thirds of players with patellar tendinopathy were at the age of 15-17 (Odds ratio 1.89) while no differences between players of the national or regional league were observed. In case of patellar tendinopathy, VISA-P was significantly lower in comparison

  1. Tailoring Superconductivity with Quantum Dislocations.

    PubMed

    Li, Mingda; Song, Qichen; Liu, Te-Huan; Meroueh, Laureen; Mahan, Gerald D; Dresselhaus, Mildred S; Chen, Gang

    2017-08-09

    Despite the established knowledge that crystal dislocations can affect a material's superconducting properties, the exact mechanism of the electron-dislocation interaction in a dislocated superconductor has long been missing. Being a type of defect, dislocations are expected to decrease a material's superconducting transition temperature (T c ) by breaking the coherence. Yet experimentally, even in isotropic type I superconductors, dislocations can either decrease, increase, or have little influence on T c . These experimental findings have yet to be understood. Although the anisotropic pairing in dirty superconductors has explained impurity-induced T c reduction, no quantitative agreement has been reached in the case a dislocation given its complexity. In this study, by generalizing the one-dimensional quantized dislocation field to three dimensions, we reveal that there are indeed two distinct types of electron-dislocation interactions. Besides the usual electron-dislocation potential scattering, there is another interaction driving an effective attraction between electrons that is caused by dislons, which are quantized modes of a dislocation. The role of dislocations to superconductivity is thus clarified as the competition between the classical and quantum effects, showing excellent agreement with existing experimental data. In particular, the existence of both classical and quantum effects provides a plausible explanation for the illusive origin of dislocation-induced superconductivity in semiconducting PbS/PbTe superlattice nanostructures. A quantitative criterion has been derived, in which a dislocated superconductor with low elastic moduli and small electron effective mass and in a confined environment is inclined to enhance T c . This provides a new pathway for engineering a material's superconducting properties by using dislocations as an additional degree of freedom.

  2. 21 CFR 888.3025 - Passive tendon prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Passive tendon prosthesis. 888.3025 Section 888...) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3025 Passive tendon prosthesis. (a) Identification. A passive tendon prosthesis is a device intended to be implanted made of silicon elastomer or a...

  3. 21 CFR 888.3025 - Passive tendon prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Passive tendon prosthesis. 888.3025 Section 888...) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3025 Passive tendon prosthesis. (a) Identification. A passive tendon prosthesis is a device intended to be implanted made of silicon elastomer or a...

  4. Reliability and Validity of the Korean Version VISA-P Questionnaire for Patellar Tendinopathy in Adolescent Elite Volleyball Athletes.

    PubMed

    Park, Byung-Hyun; Seo, Jeong-Hwan; Ko, Myoung-Hwan; Park, Sung-Hee

    2013-10-01

    To translate the English Victorian Institute of Sport Assessment for patellar tendinopathy (VISA-P) questionnaire into a Korean version and to determine the reliability and validity of the Korean version. The English VISA-P questionnaire was translated into Korean according to the internationally recommended guidelines. Then, 28 adolescent elite volleyball athletes (average age, 16 years; range, 14 to 19 years) were asked to complete the questionnaire three times (before examination, after examination, and 1 week later) for reliability. They were evaluated through a physical examination and ultrasonography to diagnosis patellar tendinopathy. The internal consistency of the VISA-P questionnaire by Cronbach's alpha was 0.80 for the first, 0.78 for the second, and 0.79 for the third assessment. The intraclass correlation coefficient (ICC) between the first and second assessments was 0.97. The ICC between the second and third assessments was 0.96. The mean VISA-P scores were 67.6±15.7 for the patellar tendinopathy group (n=23) and 92.6±8.6 for the normal group (n=5). There were significantly lower VISA-P scores in the patellar tendinopathy group compared to the normal group. The translated Korean version VISA-P questionnaire has good internal consistency, test-retest reliability and validity. In addition, this study indicated that most adolescent elite volleyball athletes had patellar tendon problems. Therefore, the Korean version VISA-P is a useful self-administered outcome score of athletes with patellar tendinopathy.

  5. Statistical analysis of dislocations and dislocation boundaries from EBSD data.

    PubMed

    Moussa, C; Bernacki, M; Besnard, R; Bozzolo, N

    2017-08-01

    Electron BackScatter Diffraction (EBSD) is often used for semi-quantitative analysis of dislocations in metals. In general, disorientation is used to assess Geometrically Necessary Dislocations (GNDs) densities. In the present paper, we demonstrate that the use of disorientation can lead to inaccurate results. For example, using the disorientation leads to different GND density in recrystallized grains which cannot be physically justified. The use of disorientation gradients allows accounting for measurement noise and leads to more accurate results. Misorientation gradient is then used to analyze dislocations boundaries following the same principle applied on TEM data before. In previous papers, dislocations boundaries were defined as Geometrically Necessary Boundaries (GNBs) and Incidental Dislocation Boundaries (IDBs). It has been demonstrated in the past, through transmission electron microscopy data, that the probability density distribution of the disorientation of IDBs and GNBs can be described with a linear combination of two Rayleigh functions. Such function can also describe the probability density of disorientation gradient obtained through EBSD data as reported in this paper. This opens the route for determining IDBs and GNBs probability density distribution functions separately from EBSD data, with an increased statistical relevance as compared to TEM data. The method is applied on deformed Tantalum where grains exhibit dislocation boundaries, as observed using electron channeling contrast imaging. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Chondromalacia induced by patellar subluxation: morphological and morphometrical aspects in rabbits.

    PubMed

    Sant'Anna, M M S; Apfel, M I R

    2002-01-01

    The purpose of this study was to describe morphologically and quantify the changes of the articular cartilage in chondromalacia, concerning both the chondrocytes and extracellular matrix. Eight rabbits were submitted daily to patellar subluxation, causing chondromalacia after two weeks. The knee fragments obtained were processed by the standard methods. These experimental conditions caused degenerative alterations of the articular cartilage, varying from a slight decrease of proteoglycans, to fibrillations, clefts, and horizontal splitting. The results showed a significantly increase number of chondrocytes (p < 0,000139), although smaller in size (p < 0,000109). The immobilization for 2 weeks and the intermittent passive daily motion afterwards for a period of 2 weeks, was effective to cause patellar chrondomalacia in rabbits.

  7. Frequency of technical complications in fixed implant prosthesis: the effect of prosthesis screw emergence correction by CAD-CAM.

    PubMed

    Anitua, Eduardo; Flores, Carlos; Piñas, Laura; Alkhraisat, Mohammad

    2018-06-05

    CAD-CAM technology permits the angular correction of screw emergence into the prosthesis, however there is lack of controlled clinical studies that assess the frequency of technical complications in angled screw channel restorations. This controlled clinical study was designed to assess technical incidences in angled screw channel restorations. Patients having implant prosthesis placed between November, 2014 and December, 2015 were screened. The patients were selected if they received prosthesis with up to 30º correction of the prosthesis screw emergence and had at least one non-angulated prosthesis (screw-retained). All the prostheses were located completely/partially in the posterior region. The frequency of technical complications was the principal variable. A total of 52 patients with a mean age of 62 ± 10 years participated with a total 110 prostheses (55 in the test group and 55 in the control group). A total of 11 technical complications occurred (7 in the test group and 4 in the control group). These differences were not statistically significant. All the prostheses in both groups survived the follow-up. The correction of the screw emergence into the prosthesis has not increased the risk of technical complications in CAD-CAM implant prostheses.

  8. Prophylactic training in asymptomatic soccer players with ultrasonographic abnormalities in Achilles and patellar tendons: the Danish Super League Study.

    PubMed

    Fredberg, Ulrich; Bolvig, Lars; Andersen, Niels T

    2008-03-01

    A recent study published in The American Journal of Sports Medicine showed that asymptomatic soccer players with an increased risk of developing Achilles and patellar tendon injuries within the next 12 months can be identified with use of ultrasonography. Prophylactic eccentric training and stretching can reduce both the frequency of asymptomatic ultrasonographic changes in Achilles and patellar tendons in soccer players and the risk of these asymptomatic intratendinous changes becoming symptomatic. Randomized controlled trial; Level of evidence, 1. Two hundred and nine Danish professional soccer players from the best national league (Super League) were followed over 12 months with use of ultrasonography and injury registration. Half the teams were randomized to an intervention group with prophylactic eccentric training and stretching of the Achilles and patellar tendons during the soccer season. The eccentric training and stretching did not reduce the injury risk, and, contrary to all expectations, the injury risk during the season was increased in players with abnormal patellar tendons at the beginning of the study in January. Eccentric training and stretching in players with normal patellar tendons significantly reduced the proportion of players with ultrasonographic changes in the patellar tendons at the end of the season (risk difference [RD] = 12%; 95% confidence interval [CI], 2%-22%; P = .02), but the training had no effect on the Achilles tendons (RD = 1%; 95% CI, -7% to 9%; P = .75). The presence of preseason ultrasonographic abnormalities in the tendons significantly increased the risk of developing tendon symptoms during the season (relative risk = 1.9; 95% CI, 1.2-3.1; P = .009). This study demonstrates that with the use of ultrasonography, tendon changes in soccer players can be diagnosed before they become symptomatic. The prophylactic eccentric training and stretching program reduces the risk of developing ultrasonographic abnormalities in the

  9. Supersonic Dislocation Bursts in Silicon

    DOE PAGES

    Hahn, E. N.; Zhao, S.; Bringa, E. M.; ...

    2016-06-06

    Dislocations are the primary agents of permanent deformation in crystalline solids. Since the theoretical prediction of supersonic dislocations over half a century ago, there is a dearth of experimental evidence supporting their existence. Here we use non-equilibrium molecular dynamics simulations of shocked silicon to reveal transient supersonic partial dislocation motion at approximately 15 km/s, faster than any previous in-silico observation. Homogeneous dislocation nucleation occurs near the shock front and supersonic dislocation motion lasts just fractions of picoseconds before the dislocations catch the shock front and decelerate back to the elastic wave speed. Applying a modified analytical equation for dislocation evolutionmore » we successfully predict a dislocation density of 1.5 x 10(12) cm(-2) within the shocked volume, in agreement with the present simulations and realistic in regards to prior and on-going recovery experiments in silicon.« less

  10. Supersonic Dislocation Bursts in Silicon

    PubMed Central

    Hahn, E. N.; Zhao, S.; Bringa, E. M.; Meyers, M. A.

    2016-01-01

    Dislocations are the primary agents of permanent deformation in crystalline solids. Since the theoretical prediction of supersonic dislocations over half a century ago, there is a dearth of experimental evidence supporting their existence. Here we use non-equilibrium molecular dynamics simulations of shocked silicon to reveal transient supersonic partial dislocation motion at approximately 15 km/s, faster than any previous in-silico observation. Homogeneous dislocation nucleation occurs near the shock front and supersonic dislocation motion lasts just fractions of picoseconds before the dislocations catch the shock front and decelerate back to the elastic wave speed. Applying a modified analytical equation for dislocation evolution we successfully predict a dislocation density of 1.5 × 1012 cm−2 within the shocked volume, in agreement with the present simulations and realistic in regards to prior and on-going recovery experiments in silicon. PMID:27264746

  11. Supersonic Dislocation Bursts in Silicon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hahn, E. N.; Zhao, S.; Bringa, E. M.

    Dislocations are the primary agents of permanent deformation in crystalline solids. Since the theoretical prediction of supersonic dislocations over half a century ago, there is a dearth of experimental evidence supporting their existence. Here we use non-equilibrium molecular dynamics simulations of shocked silicon to reveal transient supersonic partial dislocation motion at approximately 15 km/s, faster than any previous in-silico observation. Homogeneous dislocation nucleation occurs near the shock front and supersonic dislocation motion lasts just fractions of picoseconds before the dislocations catch the shock front and decelerate back to the elastic wave speed. Applying a modified analytical equation for dislocation evolutionmore » we successfully predict a dislocation density of 1.5 x 10(12) cm(-2) within the shocked volume, in agreement with the present simulations and realistic in regards to prior and on-going recovery experiments in silicon.« less

  12. Do Changes in Patellofemoral Joint Offset Lead to Adverse Outcomes in Total Knee Arthroplasty With Patellar Resurfacing? A Radiographic Review.

    PubMed

    Matz, Jacob; Howard, James L; Morden, David J; MacDonald, Steven J; Teeter, Matthew G; Lanting, Brent A

    2017-03-01

    Patellofemoral joint biomechanics contribute to anterior knee pain, instability, and dysfunction following total knee arthroplasty (TKA). Information about specific factors leading to anterior knee pain and dysfunction is currently limited. Changes in patellofemoral joint offset (PFO) refers to a mismatch between the preoperative and postoperative anteroposterior geometry of the patellofemoral joint. It remains unclear whether these changes lead to adverse outcomes in TKA. A retrospective radiographic review of 970 knees pre-TKA and post-TKA was completed to correlate the radiographic and clinical outcomes of changing the PFO using a posterior-stabilized single knee design with patellar resurfacing. A total of 970 patients were reviewed. Postoperatively, the anterior femoral offset, anteroposterior femoral size, and anterior patellar offset were changed in 40%, 60%, and 71% of knees, respectively, compared to preoperative values. The Western Ontario and McMasters Osteoarthritis Index total score as well as subscale scores for pain and function were not significantly affected by an increase or decrease in PFO. Similarly, Knee Society Scores and range of motion were not significantly affected. Increased anterior patellar offset was, however, associated with increased postoperative patellar tilt. Postoperative patellar tilt was not correlated with adverse patient satisfaction scores or loss of range of motion. Changes in PFO (decreased, maintained, or increased) are common post-TKA and are not associated with a difference in clinical outcomes. Increases in anterior patellar offset led to increased patellar tilt, which was not associated with adverse patient satisfaction scores. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Duocentric® reversed shoulder prosthesis and Personal Fit® templates: innovative strategies to optimize prosthesis positioning and prevent scapular notching.

    PubMed

    Trouilloud, P; Gonzalvez, M; Martz, P; Charles, H; Handelberg, F; Nyffeler, R W; Baulot, E

    2014-05-01

    We describe our experience with a new system of patient-specific template called Personal Fit(®), which is unique in shoulder surgery and used in combination with Duocentric(®) prosthesis. The reverse prosthesis's concept is the invention of Paul Grammont, developed with Grammont's team of Dijon University as from 1981, which led to the first reversed total shoulder prosthesis called Trumpet in 1985. The Duocentric(®) prosthesis developed in 2001 is the third-generation prosthesis, coming from the Trumpet and the second-generation prosthesis Delta(®) (DePuy). This prosthesis provides a novel solution to the notching problem with an inferior overhang integrated onto the glenoid baseplate. Personal Fit(®) system is based on reconstructing the shoulder joint bones in three dimensions using CT scan data, placing a landmark on the scapula and locating points on the glenoid and humerus. That will be used as a reference for the patient-specific templates. We study the glenoid position planned with Personal Fit(®) software relative to native glenoid position in 30 cases. On average, the difference between the planned retroversion (or anteversion in one case) and native retroversion was 8.6°.

  14. Knee extensor dynamics in the volleyball approach jump: the influence of patellar tendinopathy.

    PubMed

    Sorenson, Shawn C; Arya, Shruti; Souza, Richard B; Pollard, Christine D; Salem, George J; Kulig, Kornelia

    2010-09-01

    Controlled laboratory study using a cross-sectional design. To evaluate knee joint dynamics in elite volleyball players with and without a history of patellar tendinopathy, focusing on mechanical energy absorption and generation. We hypothesized that tendinopathy would be associated withreduced net joint work and net joint power. Patellar tendinopathy is a common, debilitating injury affecting competitive volleyball players. Thirteen elite male players with and without a history of patellar tendinopathy (mean ± SD age, 27 ± 7 years) performed maximum-effort volleyball approach jumps. Sagittal plane knee joint kinematics, kinetics, and energetics were quantified in the lead limb, using data obtained from a force platform and an 8-camera motion analysis system. Vertical ground reaction forces and pelvis vertical velocity at takeoff were examined. Independent sample t tests were used to evaluate group differences (α = .05). The tendinopathy group, compared to controls, demonstrated significant reductions (approximately 30%) in net joint work and net joint power during the eccentric phase of the jump, with no differences in the concentric phase. Positive to-negative net joint work and net joint power ratios were significantly higher in the tendinopathy group, which had a net joint work ratio of 1.00 (95% CI: 0.77, 1.24) versus 0.76 (95% CI: 0.64, 0.88) for controls, and a net joint power ratio of 1.62 (95% CI: 1.15, 2.10) versus 1.00 (95% CI: 0.80, 1.21) for controls. There were no significant differences in net joint moment, angular velocity, or range of motion. Peak vertical ground reaction forces were lower for the tendinopathy group, while average vertical ground reaction forces and pelvis vertical velocity were similar. Patellar tendinopathy is associated with differences in sagittal plane mechanical energy absorption at the knee during maximum-effort volleyball approach jumps. Net joint work and net joint power may help define underlying mechanisms, adaptive

  15. Multivariate prediction of upper limb prosthesis acceptance or rejection.

    PubMed

    Biddiss, Elaine A; Chau, Tom T

    2008-07-01

    To develop a model for prediction of upper limb prosthesis use or rejection. A questionnaire exploring factors in prosthesis acceptance was distributed internationally to individuals with upper limb absence through community-based support groups and rehabilitation hospitals. A total of 191 participants (59 prosthesis rejecters and 132 prosthesis wearers) were included in this study. A logistic regression model, a C5.0 decision tree, and a radial basis function neural network were developed and compared in terms of sensitivity (prediction of prosthesis rejecters), specificity (prediction of prosthesis wearers), and overall cross-validation accuracy. The logistic regression and neural network provided comparable overall accuracies of approximately 84 +/- 3%, specificity of 93%, and sensitivity of 61%. Fitting time-frame emerged as the predominant predictor. Individuals fitted within two years of birth (congenital) or six months of amputation (acquired) were 16 times more likely to continue prosthesis use. To increase rates of prosthesis acceptance, clinical directives should focus on timely, client-centred fitting strategies and the development of improved prostheses and healthcare for individuals with high-level or bilateral limb absence. Multivariate analyses are useful in determining the relative importance of the many factors involved in prosthesis acceptance and rejection.

  16. Dislocation dynamics simulations of interactions between gliding dislocations and radiation induced prismatic loops in zirconium

    NASA Astrophysics Data System (ADS)

    Drouet, Julie; Dupuy, Laurent; Onimus, Fabien; Mompiou, Frédéric; Perusin, Simon; Ambard, Antoine

    2014-06-01

    The mechanical behavior of Pressurized Water Reactor fuel cladding tubes made of zirconium alloys is strongly affected by neutron irradiation due to the high density of radiation induced dislocation loops. In order to investigate the interaction mechanisms between gliding dislocations and loops in zirconium, a new nodal dislocation dynamics code, adapted to Hexagonal Close Packed metals, has been used. Various configurations have been systematically computed considering different glide planes, basal or prismatic, and different characters, edge or screw, for gliding dislocations with -type Burgers vectors. Simulations show various interaction mechanisms such as (i) absorption of a loop on an edge dislocation leading to the formation of a double super-jog, (ii) creation of a helical turn, on a screw dislocation, that acts as a strong pinning point or (iii) sweeping of a loop by a gliding dislocation. It is shown that the clearing of loops is more favorable when the dislocation glides in the basal plane than in the prismatic plane explaining the easy dislocation channeling in the basal plane observed after neutron irradiation by transmission electron microscopy.

  17. A continuum theory of edge dislocations

    NASA Astrophysics Data System (ADS)

    Berdichevsky, V. L.

    2017-09-01

    Continuum theory of dislocation aims to describe the behavior of large ensembles of dislocations. This task is far from completion, and, most likely, does not have a "universal solution", which is applicable to any dislocation ensemble. In this regards it is important to have guiding lines set by benchmark cases, where the transition from a discrete set of dislocations to a continuum description is made rigorously. Two such cases have been considered recently: equilibrium of dislocation walls and screw dislocations in beams. In this paper one more case is studied, equilibrium of a large set of 2D edge dislocations placed randomly in a 2D bounded region. The major characteristic of interest is energy of dislocation ensemble, because it determines the structure of continuum equations. The homogenized energy functional is obtained for the periodic dislocation ensembles with a random contents of the periodic cell. Parameters of the periodic structure can change slowly on distances of order of the size of periodic cells. The energy functional is obtained by the variational-asymptotic method. Equilibrium positions are local minima of energy. It is confirmed the earlier assertion that energy density of the system is the sum of elastic energy of averaged elastic strains and microstructure energy, which is elastic energy of the neutralized dislocation system, i.e. the dislocation system placed in a constant dislocation density field making the averaged dislocation density zero. The computation of energy is reduced to solution of a variational cell problem. This problem is solved analytically. The solution is used to investigate stability of simple dislocation arrays, i.e. arrays with one dislocation in the periodic cell. The relations obtained yield two outcomes: First, there is a state parameter of the system, dislocation polarization; averaged stresses affect only dislocation polarization and cannot change other characteristics of the system. Second, the structure of

  18. Surgical repair of chronic patellar tendon rupture in total knee replacement with ipsilateral hamstring tendons.

    PubMed

    Spoliti, Marco; Giai Via, Alessio; Padulo, Johnny; Oliva, Francesco; Del Buono, Angelo; Maffulli, Nicola

    2016-10-01

    Patellar tendon rupture is a serious complication of total knee arthroplasty (TKA). Its reconstruction in patients with chronic ruptures is technically demanding. This article reports the results of surgical reconstruction of neglected patellar tendon rupture in TKA using autologous hamstring tendons. Nine TKA patients (six women and three men) (mean age at index surgery 68 years) with chronic patellar tendon tears underwent reconstruction with ipsilateral hamstrings tendon, leaving the distal insertion in situ. The clinical diagnosis was supported by imaging (anterior-posterior and 30° flexion lateral radiographs). Insall-Salvati index, range of motion, and leg extension test were recorded preoperatively and at last follow-up. The modified Cincinnati rating system and the Kujala score were administered. The patients sustained the patellar tendon tear an average of 8 weeks before the procedure. At final follow-up of 4 years (range 2-8 years), the median of extension lag was 5° (range 0°-15°; DS = 5). The median of post-operative Insall-Salvati index was 1.4 (range 1.3-1.8; SD = 0.15; p = 0.002) compared to the preoperative index of 1.7 (range 1.5-2.2; SD = 0.23). The mean modified Cincinnati and Kujala scores significantly increased compared with the preoperative ones (p < 0.01). At final follow-up, all patients were able to walk without brace or aids, and they were satisfied with the procedure. Based on our retrospective study of nine patients, reconstruction of neglected patellar tendon rupture in TKA with autologous hamstring tendons is feasible and safe, and provides good functional recovery. Case series, Level IV.

  19. Structural and in vivo mechanical characterization of canine patellar cartilage: a closed chondromalacia patellae model.

    PubMed

    LaBerge, M; Audet, J; Drouin, G; Rivard, C H

    1993-01-01

    The purpose of this project was to study the relationship between the structure of the patellar cartilage and its response to static compressive loading with a closed chondromalacia patellae model. An animal model was used to induce degeneration of the patella that was monitored quantitatively and qualitatively as a function of time. Ten adult mongrel dogs had their left patellofemoral groove replaced by a customized metallic implant covered with a thin film of polyethylene for periods of 3 months (five dogs) and 6 months (five dogs). An indenter was designed to perform mechanical indentation testing on the patellar cartilage in situ. The animals were anesthetized and the response of patellar cartilage to a static compressive load of 4.5 MPa was monitored for 20 min and its relaxation after load removal for 20 min. Indentation tests were performed every 3 months of the implantation period. At the end of the implantation period, the patellae were processed for histology, and sections were stained with Safranin-O indicative of the proteoglycans content. Macroscopically, no apparent degeneration or fibrillation of the patellar surfaces was observed after 3 or 6 months of implantation. However, the patellar surface showed a change in coloration after 6 months. A 17 +/- 3% and 37 +/- 8% deformation of the cartilage were calculated for the 3-month and 6-month specimens, respectively. Histologically, a progressive loss of proteoglycans was observed in the matrix as a function of implantation time. These results indicated that an increase in cartilage compliance is associated with an intrinsic remodeling of the cartilage matrix and that these changes might occur without external signs of degeneration and can be quantified.

  20. Knee Dislocations

    PubMed Central

    Schenck, Robert C.; Richter, Dustin L.; Wascher, Daniel C.

    2014-01-01

    Background: Traumatic knee dislocation is becoming more prevalent because of improved recognition and increased exposure to high-energy trauma, but long-term results are lacking. Purpose: To present 2 cases with minimum 20-year follow-up and a review of the literature to illustrate some of the fundamental principles in the management of the dislocated knee. Study Design: Review and case reports. Methods: Two patients with knee dislocations who underwent multiligamentous knee reconstruction were reviewed, with a minimum 20-year follow-up. These patients were brought back for a clinical evaluation using both subjective and objective measures. Subjective measures include the following scales: Lysholm, Tegner activity, visual analog scale (VAS), Short Form–36 (SF-36), International Knee Documentation Committee (IKDC), and a psychosocial questionnaire. Objective measures included ligamentous examination, radiographic evaluation (including Telos stress radiographs), and physical therapy assessment of function and stability. Results: The mean follow-up was 22 years. One patient had a vascular injury requiring repair prior to ligament reconstruction. The average assessment scores were as follows: SF-36 physical health, 52; SF-36 mental health, 59; Lysholm, 92; IKDC, 86.5; VAS involved, 10.5 mm; and VAS uninvolved, 2.5 mm. Both patients had excellent stability and were functioning at high levels of activity for their age (eg, hiking, skydiving). Both patients had radiographic signs of arthritis, which lowered 1 subject’s IKDC score to “C.” Conclusion: Knee dislocations have rare long-term excellent results, and most intermediate-term studies show fair to good functional results. By following fundamental principles in the management of a dislocated knee, patients can be given the opportunity to function at high levels. Hopefully, continued advances in the evaluation and treatment of knee dislocations will improve the long-term outcomes for these patients in the

  1. “Conjugate Channeling” Effect in Dislocation Core Diffusion: Carbon Transport in Dislocated BCC Iron

    PubMed Central

    Ishii, Akio; Li, Ju; Ogata, Shigenobu

    2013-01-01

    Dislocation pipe diffusion seems to be a well-established phenomenon. Here we demonstrate an unexpected effect, that the migration of interstitials such as carbon in iron may be accelerated not in the dislocation line direction , but in a conjugate diffusion direction. This accelerated random walk arises from a simple crystallographic channeling effect. is a function of the Burgers vector b, but not , thus a dislocation loop possesses the same everywhere. Using molecular dynamics and accelerated dynamics simulations, we further show that such dislocation-core-coupled carbon diffusion in iron has temperature-dependent activation enthalpy like a fragile glass. The 71° mixed dislocation is the only case in which we see straightforward pipe diffusion that does not depend on dislocation mobility. PMID:23593255

  2. Does Patellar Eversion in Total Knee Arthroplasty Cause Patella Baja?

    PubMed Central

    Sharma, Vineet; Tsailas, Panagiotis G.; Maheshwari, Aditya V.; Ranawat, Chitranjan S.

    2008-01-01

    Several proponents of minimally invasive surgery-total knee arthroplasty (MIS-TKA) have suggested patellar eversion during a standard exposure of the knee may cause shortening of the patellar tendon and poorer outcomes secondary to acquired patella baja. To explore this suggestion, we retrospectively reviewed 135 consecutive TKAs in 110 patients to ascertain the effect of TKA on the postoperative Insall-Salvati ratio. All surgeries were performed using standard TKA techniques with a midline incision, medial parapatellar arthrotomy, partial excision of the fat pad, and routine eversion of the patella. One patient developed a postoperative patella baja, defined as an Insall-Salvati ratio of less than 0.8. The Knee Society score for knee and function in this patient was 75 and 70, respectively. Five additional patients had a decrease in Insall-Salvati ratio by 10% or more but without patella baja. Mean Knee Society score for knee and function in these five patients was 94 (range, 73–99) and 96 (range, 90–100), respectively, as compared with 93 (range, 37–99) and 94 (range, 40–100) in the remaining 104 patients. Our data suggest the incidence of patella baja is low after TKA despite routine patellar eversion. Furthermore, a 10% or more decrease in the Insall-Salvati ratio without patella baja was not associated with a worse clinical outcome. Level of Evidence: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence. PMID:18568378

  3. Evaluation of anterior knee pain in a PS total knee arthroplasty: the role of patella-friendly femoral component and patellar size.

    PubMed

    Atzori, F; Sabatini, L; Deledda, D; Schirò, M; Lo Baido, R; Baido, R L; Massè, A

    2015-04-01

    Total knee arthroplasty gives excellent objective results. Nevertheless, the subjective findings do not match the normal knee perception: Often, it depends on patellar pain onset. In this study, we analyzed clinical and radiological items that can affect resurfaced patellar tracking, and role of a patella-friendly femoral component and patellar size on patellar pain onset. Thirty consecutive patients were implanted using the same-cemented posterior-stabilized TKA associated with patella resurfacing. Fifteen patients were implanted using a classical femoral component, while another 15 patients were implanted using a patella-friendly femoral component. The statistical analysis was set to detect a significant difference (p < 0.05) in clinical and radiological outcomes related to several surgical parameters. Clinical and functional outcomes were recorded using the Knee Society Scoring System (KSS) and patellar pain with the Burnett questionnaire. Mean follow-up was 25 months. KSS results were excellent in both groups. Group 2 (patella-friendly femoral model) reached a higher percentage of 100 points in the clinical and functional KSS, but there was no statistical difference. Also, no statistical differences for Burnett Questionnaire results were recorded. We had one case of patellar clunk syndrome in the standard femoral component group and one poor result in the second group. Postoperative radiographic measurements evidenced no statistical differences in both groups. In group 1 (classical femoral component), better significant result (p < 0.05) war recorded at clinical evaluation according to the Knee Society Scoring System (KSS) in case of wider patellar component resurfaced. The present study reveals no statistically significant difference in the incidence of anterior knee pain between classical and "patella-friendly" femoral components. With the particular type of implant design utilized in this study, when the classical femoral component is used, bigger

  4. Malrotation of the McGhan Style 510 prosthesis.

    PubMed

    Schots, Jeroen M P; Fechner, Maarten R; Hoogbergen, Maarten M; van Tits, Herm W H J

    2010-07-01

    Anatomically shaped cohesive silicone breast implants are frequently used in aesthetic and reconstructive surgery. After successful results with the Style 410 prosthesis, McGhan (Natrelle, Allergan) introduced the Style 510 prosthesis. After using this novel prosthesis, the authors encountered a high number of prosthesis malrotations on self-reported follow-up. Therefore, a retrospective medical record review was performed to determine the prevalence of malrotation of the Style 510 prosthesis. From January of 2005 to December of 2006, 73 (146 prostheses) aesthetic augmentation mammaplasty procedures were performed using Style 510 prostheses. All prostheses were placed subglandularly through an inframammary incision. The postsurgical protocol for the first 3 weeks involved wearing a nonwired compression bra, abstinence from sports activities, and abstinence from heavy labor. Standard follow-up was at 1 week, 3 months, and if necessary. On self-reported follow-up, 8.2 percent of all prostheses were rotated. These rotations all occurred unilaterally after a mean period of 10 months (range, 3 to 19 months). No relation to an inciting incident or prosthesis volume could be found. The number of rotations of the Style 510 prosthesis seen after primary aesthetic breast augmentation is high. An obvious cause of this major problem has not been found. This led the authors to discontinue using the Style 510 prosthesis for primary aesthetic mammary augmentations in their practice.

  5. Early outcome of TKA with a medial pivot fixed-bearing prosthesis is worse than with a PFC mobile-bearing prosthesis.

    PubMed

    Kim, Young-Hoo; Yoon, Sung-Hwan; Kim, Jun-Shik

    2009-02-01

    Although the design features of the Medial Pivot fixed-bearing prosthesis reportedly improve kinematics compared with TKAs using fixed-bearings, clinical improvements have not been reported. We asked whether the clinical and radiographic outcomes, ranges of motion of the knee, patient satisfaction, and complication rates would be better in knees with a Medial Pivot fixed-bearing prosthesis than in those with a PFC Sigma mobile-bearing prosthesis. We compared the results of 92 patients who had a Medial Pivot fixed-bearing prosthesis implanted in one knee and a PFC Sigma mobile-bearing prosthesis implanted in the other. There were 85 women and seven men with a mean age of 69.5 years (range, 55-81 years). The minimum followup was 2 years (mean, 2.6 years; range, 2-3 years). The patients were assessed clinically and radiographically using the rating systems of the Hospital for Special Surgery and the Knee Society at 3 months, 1 year, and annually thereafter. Contrary to expectations, we found worse early clinical outcomes, smaller ranges of knee motion, less patient satisfaction, and a higher complication rate for the Medial Pivot fixed-bearing prosthesis than for the PFC Sigma mobile-bearing prosthesis. Level I, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

  6. Quantifying the effect of hydrogen on dislocation dynamics: A three-dimensional discrete dislocation dynamics framework

    NASA Astrophysics Data System (ADS)

    Gu, Yejun; El-Awady, Jaafar A.

    2018-03-01

    We present a new framework to quantify the effect of hydrogen on dislocations using large scale three-dimensional (3D) discrete dislocation dynamics (DDD) simulations. In this model, the first order elastic interaction energy associated with the hydrogen-induced volume change is accounted for. The three-dimensional stress tensor induced by hydrogen concentration, which is in equilibrium with respect to the dislocation stress field, is derived using the Eshelby inclusion model, while the hydrogen bulk diffusion is treated as a continuum process. This newly developed framework is utilized to quantify the effect of different hydrogen concentrations on the dynamics of a glide dislocation in the absence of an applied stress field as well as on the spacing between dislocations in an array of parallel edge dislocations. A shielding effect is observed for materials having a large hydrogen diffusion coefficient, with the shield effect leading to the homogenization of the shrinkage process leading to the glide loop maintaining its circular shape, as well as resulting in a decrease in dislocation separation distances in the array of parallel edge dislocations. On the other hand, for materials having a small hydrogen diffusion coefficient, the high hydrogen concentrations around the edge characters of the dislocations act to pin them. Higher stresses are required to be able to unpin the dislocations from the hydrogen clouds surrounding them. Finally, this new framework can open the door for further large scale studies on the effect of hydrogen on the different aspects of dislocation-mediated plasticity in metals. With minor modifications of the current formulations, the framework can also be extended to account for general inclusion-induced stress field in discrete dislocation dynamics simulations.

  7. Surgical Treatment for Failure of Repair of Patellar and Quadriceps Tendon Rupture With Ipsilateral Hamstring Tendon Graft.

    PubMed

    Maffulli, Nicola; Papalia, Rocco; Torre, Guglielmo; Denaro, Vincenzo

    2017-03-01

    Tears of the patellar and quadriceps tendon are common in the active population, especially in athletes. At present, several techniques for surgical repair and reconstruction are available. When reruptures occur, a reconstruction is mandatory. In the present paper, we describe a surgical technique for patellar and quadriceps tendon reconstruction using ipsilateral hamstring autograft. After routine hamstring tendon harvesting, the tendon ends are prepared using a whip stitch. A transverse tunnel is drilled in the midportion of the patella, the hamstring graft is passed through the patella, and firmly secured to the patellar tunnel openings with sutures. The details of the technique are fully described. Autologous ipsilateral hamstring tendon grafts provide a secure sound means to manage these challenging injuries.

  8. 21 CFR 872.3940 - Total temporomandibular joint prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Total temporomandibular joint prosthesis. 872.3940... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3940 Total temporomandibular joint prosthesis. (a) Identification. A total temporomandibular joint prosthesis is a device that is intended to be...

  9. 21 CFR 872.3940 - Total temporomandibular joint prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Total temporomandibular joint prosthesis. 872.3940... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3940 Total temporomandibular joint prosthesis. (a) Identification. A total temporomandibular joint prosthesis is a device that is intended to be...

  10. Habitual dislocation of patella: A review

    PubMed Central

    Batra, Sumit; Arora, Sumit

    2014-01-01

    Habitual dislocation of patella is a condition where the patella dislocates whenever the knee is flexed and spontaneously relocates with extension of the knee. It is also termed as obligatory dislocation as the patella dislocates completely with each flexion and extension cycle of the knee and the patient has no control over the patella dislocating as he or she moves the knee1. It usually presents after the child starts to walk, and is often well tolerated in children, if it is not painful. However it may present in childhood with dysfunction and instability. Very little literature is available on habitual dislocation of patella as most of the studies have combined cases of recurrent dislocation with habitual dislocation. Many different surgical techniques have been described in the literature for the treatment of habitual dislocation of patella. No single procedure is fully effective in the surgical treatment of habitual dislocation of patella and a combination of procedures is recommended. PMID:25983506

  11. Using O*NET in Dislocated Worker Retraining: The Toledo Dislocated Worker Consortium Project.

    ERIC Educational Resources Information Center

    Sommers, Dixie; Austin, James

    A project used the Occupational Information Network (O*NET) to assist eligible dislocated workers in determining whether training offered by the Toledo Dislocated Worker Consortium fit their needs. More specifically, O*NET was used to help the dislocated workers understand whether they had knowledge and skills that were transferable into the…

  12. Operative Management of Patellar Instability in the United States: An Evaluation of National Practice Patterns, Surgical Trends, and Complications.

    PubMed

    Arshi, Armin; Cohen, Jeremiah R; Wang, Jeffrey C; Hame, Sharon L; McAllister, David R; Jones, Kristofer J

    2016-08-01

    Treatment of patellofemoral instability has evolved as our understanding of the relevant pathoanatomy has improved. In light of these developments, current practice patterns and management trends have likely changed to reflect these advancements; however, this has not been evaluated in a formal study. To determine nationwide patient demographics, surgical trends, and postoperative complications associated with the operative management of patellar instability surgery. Descriptive epidemiological study. A large private-payer database (PearlDiver) comprising patients covered by Humana and United Healthcare insurance policies was retrospectively reviewed using Current Procedural Terminology (CPT) codes to identify patients who underwent surgery for patellar instability. The study cohort was established by querying for patients billed under CPT codes 27420, 27422, or 27427 while satisfying the diagnostic requirement of patellar instability (International Classification of Diseases-9th Revision codes 718.36, 718.86, or 836.3). Patient demographics, surgical trends, concomitant procedures, and postoperative complications were determined. A total of 6190 patients underwent surgical management for patellar instability. Adolescents (age range, 10-19 years) represented 51.5% of cases, and 59.6% were female. The number of patellar instability procedures increased annually over the study period in both the Humana (P = .004, R (2) = 0.76) and United Healthcare (P = .097, R (2) = 0.54) cohorts. The most common concomitant procedures were lateral retinacular release (43.7%), chondroplasty (31.1%), tibial tubercle osteotomy (13.1%), removal of loose bodies (10.5%), osteochondral grafting (9.5%), and microfracture surgery (9.5%). Manipulation under anesthesia was required in 4.6% of patients within 1 year. Patellar fracture within 1 year and infection within 30 days occurred in 2.1% and 1.2% of patients, respectively. Patellar instability surgery has increased over the past decade

  13. Lateral Patellar Instability in the Skeletally Mature Patient: Evaluation and Surgical Management.

    PubMed

    Diduch, David R; Kandil, Abdurrahman; Burrus, M Tyrrell

    2018-05-18

    Lateral patellar instability is a common disease process that affects all types of patients. Depending on the patient's anatomy and the results of preoperative imaging, surgical management options include medial patellofemoral ligament reconstruction, tibial tubercle osteotomy, and sulcus-deepening trochleoplasty. Medial patellofemoral ligament reconstruction or repair is useful for almost all patients, whereas tibial tubercle osteotomy is helpful to correct a lateralized tibial tubercle and the associated elevated lateral pull of the extensor mechanism. For a select subset of patients with severe trochlear dysplasia, a sulcus-deepening trochleoplasty can be a useful option to prevent future patellar instability. Many technical considerations exist for each procedure, and in most situations, no consensus exists to direct surgeons on the superior technique.

  14. The Effect of Patellar Taping on Squat Depth and the Perception of Pain in People with Anterior Knee Pain

    PubMed Central

    Clifford, Amanda M.; Harrington, Elaine

    Patellar taping is a treatment adjunct commonly used in the management of anterior knee pain. The aim of this cross sectional study was to investigate the effects of medial glide patellar taping on sagittal plane lower-limb joint kinematics and knee pain during a unilateral squat in a symptomatic population complaining of anterior knee pain. Ten participants with a history of unilateral or bilateral anterior knee pain were included in the study. Subjects were required to squat on the symptomatic leg under three conditions: placebo tape, patellar tape and no tape. Kinematic data was recorded using the CODA mpx64 motion analysis system and subjects’ pain was assessed using the Numerical Rating Scale. Patellar taping resulted in a significantly greater single-legged squat depth compared to placebo tape (p=0.008) and no tape (p=0.001) and a statistically significant reduction in pain during a squat compared to placebo tape (p=0.001) or no tape (p=0.001). Significant differences were not identified for maximum knee flexion in the patella taping compared to the no tape condition. This study may have significant clinical implications as participants reported less pain and alterations in sagittal plane movement following the application of patellar tape. PMID:24146711

  15. Abnormal Patella Height Based on Insall-Salvati Ratio and its Correlation with Patellar Cartilage Lesions: An Extremity-Dedicated Low-Field Magnetic Resonance Imaging Analysis of 1703 Chinese Cases.

    PubMed

    Lu, W; Yang, J; Chen, S; Zhu, Y; Zhu, C

    2016-09-01

    Diagnostic performance of patellar position for patellar cartilage lesions remains unclear. The aim of this study was to assess the abnormal patella height and its correlation with chondral lesions of the patellofemoral joint in China. A total of 1703 consecutive patients who performed knee joint examination using an extremity-dedicated low-field magnetic resonance imaging were enrolled in this study. Patellar cartilage lesions were diagnosed based on the result of magnetic resonance imaging and clinical data. Patella height was defined as the ratio of patellar tendon length to patellar length according to Insall-Salvati index. Patella alta and infera were defined as tendon length/patellar length >1.2 and <0.8, respectively. The total prevalence of patellar cartilage lesions was 38.0%. The prevalence in females was significantly higher than that in males (46.4% vs 28.8%, p < 0.001). Age notably increased the incidence of patellar cartilage lesions (p < 0.001). Logistic regression analysis showed that tendon length/patellar length ratio was significantly correlated with patellar cartilage lesions (odds ratio = 6.380, p < 0.001). Furthermore, patients with cartilage lesions showed significantly higher rates of patella alta and infera (p < 0.001). In addition, receiver operating characteristic curve analysis demonstrated that abnormal patella height had statistical significance in diagnosing cartilage lesions (p < 0.001). However, the area under the curve (0.596; 95% confidence interval: 0.568-0.624) and sensitivity (47.0%) were relatively low, while the specificity was 72.2%. Patients with patellar cartilage lesions have an increased tendon length/patellar length ratio. The abnormal patella height is significantly correlated with chondral lesions and can be used as a potential diagnostic marker. © The Finnish Surgical Society 2015.

  16. Rare cause of knee pain after martial arts demonstration: a case report.

    PubMed

    Armstrong, Marc B; Thurber, Jalil

    2013-04-01

    Patellar dislocations are a commonly treated injury in the Emergency Department (ED), with a majority of cases involving lateral subluxation of the patella outside of the joint space. Intra-condylar dislocations of the patella are rare. Of the two types of axis rotation, vertical and horizontal, the vertical occurs five times less frequently. These injuries most often undergo open reduction or, at best, closed reduction under general anesthesia. To remind Emergency Physicians to consider this injury in any patient with severe knee pain and limited mobility, even with a history that is lacking significant trauma. We present a case of intra-condylar patellar dislocation with vertical axis rotation. This injury is no longer primarily attributed to the young and, barring fracture, closed reduction in the ED should be considered. Copyright © 2013 Elsevier Inc. All rights reserved.

  17. Non-metallic implant for patellar fracture fixation: A systematic review.

    PubMed

    Camarda, Lawrence; Morello, Salvatore; Balistreri, Francesco; D'Arienzo, Antonio; D'Arienzo, Michele

    2016-08-01

    Despite good clinical outcome proposals, there has been relatively little published regarding the use of non-metallic implant for patellar fracture fixation. The purpose of the study was to perform a systematic literature review to summarize and evaluate the clinical studies that described techniques for treating patella fractures using non-metallic implants. A comprehensive literature search was systematically performed to evaluate all studies included in the literature until November 2015. The following search terms were used: patellar fracture, patella suture, patella absorbable, patella screw, patella cerclage. Two investigators independently reviewed all abstracts and the selection of these abstracts was then performed based on inclusion and/or exclusion criteria. A total of 9 studies involving 123 patients were included. Patients had a mean age of 33.7 years and were followed up for a mean of 18.9 months. The most common method for fracture fixations included the use of suture material. Good clinical outcomes were reported among all studies. Thirteen patients (10.5%) presented complications, while 4 patients (3.2%) required additional surgery for implant removal. There is a paucity of literature focused on the use of non-metallic implant for patellar fracture fixation. However, this systematic review showed that non-metallic implants are able to deliver good clinical outcomes reducing the rate of surgical complications and re-operation. These results may assist surgeons in choosing to use alternative material such as sutures to incorporate into their routine practice or to consider it, in order to reduce the rate of re-operation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. 21 CFR 876.3750 - Testicular prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Testicular prosthesis. 876.3750 Section 876.3750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Prosthetic Devices § 876.3750 Testicular prosthesis. (a...

  19. 21 CFR 878.3610 - Esophageal prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Esophageal prosthesis. 878.3610 Section 878.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3610 Esophageal prosthesis...

  20. 21 CFR 878.3610 - Esophageal prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Esophageal prosthesis. 878.3610 Section 878.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3610 Esophageal prosthesis...

  1. 21 CFR 878.3610 - Esophageal prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Esophageal prosthesis. 878.3610 Section 878.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3610 Esophageal prosthesis...

  2. 21 CFR 878.3610 - Esophageal prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Esophageal prosthesis. 878.3610 Section 878.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3610 Esophageal prosthesis...

  3. 21 CFR 878.3610 - Esophageal prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Esophageal prosthesis. 878.3610 Section 878.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3610 Esophageal prosthesis...

  4. Cross-cultural adaptation of VISA-P score for patellar tendinopathy in Turkish population.

    PubMed

    Çelebi, Mehmet Mesut; Köse, Serdal Kenan; Akkaya, Zehra; Zergeroglu, Ali Murat

    2016-01-01

    VISA-P questionnaire assesses to severity of symptoms and treatment effects in athletes with patellar tendinopathy. The purpose of this study was to translated VISA-P questionnaire into Turkish language and to determine its validity and reliability. The English version of VISA-P questionnaire was translated into Turkish according to the internationally recommended guidelines. Test-retest reliability was determined on 89 participants with time interval 24 h. To determine validity of Turkish VISA-P, 31 (17 male, 14 female) healthy students, 34 (20 male, 14 female) patients with patellar tendinopathy (diagnosed by physical examination and ultrasonography) and 24 (16 male, 8 female) volleyball players (at risk populations) were completed VISA-P-Tr. Internal consistency was determined with Cronbach's alpha. Intraclass correlation coefficients (ICCs) were calculated to analyse test-retest reliability. To assessment of discrimination, VISA-P-Tr scores compared all groups using the Mann-Whitney-U test. The VISA-P-Tr questionnaire showed good test-retest reliability (The Cronbach's alpha was 0.79 and 0.78 respectively and ICC was 0.96). The VISA-P-Tr score (mean ± SD) were 93.7 ± 8.9 and 94.0 ± 8.1 for healthy students, 81.1 ± 13.7 and 80.7 ± 13.4 for volleyball players, 58.8 ± 12.1 and 58.5 ± 11.0 for athletes with patellar tendinopathy. The translated Turkish version of VISA-P has good internal consistency and good reliability and validity. Therefore VISA-P-Tr is useful to evaluate symptoms and follow the treatment effect in athletes with patellar tendinopathy.

  5. Aesthetic finger prosthesis with silicone biomaterial

    PubMed Central

    Raghu, K M; Gururaju, C R; Sundaresh, K J; Mallikarjuna, Rachappa

    2013-01-01

    The fabrication of finger prosthesis is as much an art as it is science. The ideally constructed prosthesis must duplicate the missing structures so precisely that patients can appear in public without fear of attracting unwanted attraction. A 65-years-old patient reported with loss of his right index finger up to the second phalanx and wanted to get it replaced. An impression of the amputated finger and donor were made. A wax pattern of the prosthesis was fabricated using the donor impression; a trial was performed and flasked. Medical grade silicone was intrinsically stained to match the skin tone, following which it was packed, processed and finished. This clinical report describes a method of attaining retention by selective scoring of the master cast of partially amputated finger to enhance the vacuum effect at par with the proportional distribution of the positive forces on the tissues exerted by the prosthesis. PMID:23975917

  6. Reconstruction of a ruptured patellar tendon using ipsilateral semitendinosus and gracilis tendons with preserved distal insertions: two case reports

    PubMed Central

    2013-01-01

    Background Acute patellar tendon ruptures with poor tissue quality. Ruptures that have been neglected are difficult to repair. Several surgical techniques for the repair of the patellar tendon have been reported, however, these techniques remain difficult because of contractures, adhesions, and atrophy of the quadriceps muscle after surgery. Case presentation We report the cases of 2 Japanese patients (Case 1: a 16-year-old male and Case 2: a 43-year-old male) with patellar tendon ruptures who were treated by reconstruction using semitendinosus-gracilis (STG) tendons with preserved distal insertions. Retaining the original insertion of the STG appears to preserve its viability and provide the revascularization necessary to accelerate healing. Both tendons were placed in front of the patella, in a figure-of-eight fashion, providing stability to the patella. Conclusion Both patients recovered near normal strength and stability of the patellar tendon as well as restoration of function after the operation. PMID:24010848

  7. [Simultaneous Traumatic Rupture of Patellar Ligament and Contralateral Rupture of Quadriceps Femoris Muscle].

    PubMed

    Hladký, V; Havlas, V

    2017-01-01

    Our paper presents a unique case of a 64-year-old patient after a fall, treated with oral antidiabetic drugs for type II diabetes mellitus. Following a series of examinations, a bilateral injury was diagnosed - patellar ligament tear on the right side and rupture of quadriceps femoris muscle on the left side. It is a rare injury, complicated by simultaneous involvement of both knee joints. The used therapy consisted of a bilateral surgery followed by gradual verticalisation, first with the support of a walking frame and later with the use of forearm crutches. During the final examination, the patient demonstrated full flexion at both knees, while an extension deficit of approx. 5 degrees was still present on the left side. The right knee X-ray showed a proper position of the patella after the removal of temporary tension band wire. Although the clinical results of operative treatment of both the patellar ligament rupture and rupture of quadriceps femoris muscle are in most cases good, early operative treatment, proper technique and post-operative rehabilitation are a prerequisite for success. Key words: knee injuries, patellar ligament, quadriceps muscle, rupture.

  8. Three-dimensional formulation of dislocation climb

    NASA Astrophysics Data System (ADS)

    Gu, Yejun; Xiang, Yang; Quek, Siu Sin; Srolovitz, David J.

    2015-10-01

    We derive a Green's function formulation for the climb of curved dislocations and multiple dislocations in three-dimensions. In this new dislocation climb formulation, the dislocation climb velocity is determined from the Peach-Koehler force on dislocations through vacancy diffusion in a non-local manner. The long-range contribution to the dislocation climb velocity is associated with vacancy diffusion rather than from the climb component of the well-known, long-range elastic effects captured in the Peach-Koehler force. Both long-range effects are important in determining the climb velocity of dislocations. Analytical and numerical examples show that the widely used local climb formula, based on straight infinite dislocations, is not generally applicable, except for a small set of special cases. We also present a numerical discretization method of this Green's function formulation appropriate for implementation in discrete dislocation dynamics (DDD) simulations. In DDD implementations, the long-range Peach-Koehler force is calculated as is commonly done, then a linear system is solved for the climb velocity using these forces. This is also done within the same order of computational cost as existing discrete dislocation dynamics methods.

  9. The effect of isolated dislocations on substrate and device properties in low-dislocation czochralski GaAs

    NASA Astrophysics Data System (ADS)

    Hunter, A. T.; Kimura, H.; Olsen, H. M.; Winston, H. V.

    1986-07-01

    Czochralski GaAs grown with In incorporated into the melt has large regions with fewer than 100 cm-2 dislocations. We have examined the effect of these dislocations on substrate and device properties. Infrared transmission images reveal dark filaments of high EL2 concentration a few tens of microns in diameter surrounding dislocations, Cathodo and photoluminescence images show orders of magnitude contrast in band-edge luminescence intensity near dislocations. Single dislocations appear to be surrounded by bright rings ˜200 μm in diameter in luminescence images, with dark spots 50 to 75 μm across centered on the dislocation. More complex luminescence structures with larger dark regions (˜150 μ across) and central bright spots are centered on small dislocation clusters. Differences in lifetime of photogenerated electrons or holes are the most likely cause of the luminescence contrast. Anneals typical of our post-implant processing substantially lower the luminescence contrast, suggesting the defect lowering the lifetime is removed by annealing. This may partially explain why we do not observe any effect of dislocation proximity on the properties of devices made in the material, in spite of the enormous luminescence contrast observed near dislocations.

  10. Adjustable patella grapple versus cannulated screw and cable technique for treatment of transverse patellar fractures.

    PubMed

    Yan, Ning; Yang, Anli; Liu, Xiaodong; Cai, Feng; Liu, Liang; Chang, Shimin

    2014-03-01

    Although the cannulated screw and cable (CSC) tension band technique is an effective method for fixation of transverse patellar fractures, it has shortcomings, such as extensive soft tissue damage, osseous substance damage, and complex manipulation. We conducted a retrospective comparison of the adjustable patella grapple (APG) technique and the CSC tension band technique. We retrospectively reviewed 78 patients with transverse patellar fractures (45 in the APG group and 33 in the CSC group). Follow-up was 18 months. Comparison criteria were operation time, fracture reduction, fracture healing time, the knee injury and osteoarthritis outcome score for knee function, and complications. The APG group showed shorter operation time and equal fracture reduction, fracture healing time, and knee function compared with the CSC group. Eleven patients in the APG group experienced skin irritation generated by implants. There was no complication in the CSC group. The APG technique should be considered as an alternative method for treatment of transverse patellar fractures.

  11. 21 CFR 878.3680 - Nose prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Nose prosthesis. 878.3680 Section 878.3680 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3680 Nose prosthesis. (a...

  12. 21 CFR 878.3550 - Chin prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Chin prosthesis. 878.3550 Section 878.3550 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3550 Chin prosthesis. (a...

  13. 21 CFR 878.3720 - Tracheal prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Tracheal prosthesis. 878.3720 Section 878.3720 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3720 Tracheal prosthesis. (a...

  14. 21 CFR 878.3550 - Chin prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Chin prosthesis. 878.3550 Section 878.3550 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3550 Chin prosthesis. (a...

  15. 21 CFR 878.3550 - Chin prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Chin prosthesis. 878.3550 Section 878.3550 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3550 Chin prosthesis. (a...

  16. 21 CFR 878.3550 - Chin prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Chin prosthesis. 878.3550 Section 878.3550 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3550 Chin prosthesis. (a...

  17. 21 CFR 878.3550 - Chin prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Chin prosthesis. 878.3550 Section 878.3550 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3550 Chin prosthesis. (a...

  18. 21 CFR 878.3680 - Nose prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nose prosthesis. 878.3680 Section 878.3680 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3680 Nose prosthesis. (a...

  19. 21 CFR 878.3680 - Nose prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Nose prosthesis. 878.3680 Section 878.3680 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3680 Nose prosthesis. (a...

  20. 21 CFR 878.3680 - Nose prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nose prosthesis. 878.3680 Section 878.3680 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3680 Nose prosthesis. (a...

  1. 21 CFR 878.3680 - Nose prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Nose prosthesis. 878.3680 Section 878.3680 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3680 Nose prosthesis. (a...

  2. Regional strain variations in the human patellar tendon.

    PubMed

    Pearson, Stephen J; Ritchings, Tim; Mohamed, Azlan S A

    2014-07-01

    Characteristics of localized tendon strain in vivo are largely unknown. The present study examines local tendon strain between the deep, middle, and surface structures at the proximal and distal aspects of the patellar tendon during ramped isometric contractions. Male subjects (age 28.0 ± 6.3 yr) were examined for patellar tendon excursion (anterior, midsection, and posterior) during ramped isometric voluntary contractions using real-time B-mode ultrasonography and dynamometry. Regional tendon excursion measurements were compared using an automated pixel tracking method. Strain was determined from the tendon delta length normalized to initial/resting segment length. Strain increased from 10% to 100% of force for all regions. Significantly greater mean strain was seen for the anterior proximal region compared to the posterior and mid layer of the tendon (7.5% ± 1.1% vs 3.7% ± 0.5% vs 5.5% ± 1.0%; P < 0.05). Similarly, the distal posterior region showed greater mean strain compared to the mid and anterior regions (7.9% ± 0.6% vs 5.0% ± 0.6% vs 5.4% ± 0.6%; P < 0.05). Relative changes in strain differences from 50% to 100% of force for the proximal region were greatest for the anterior to midline regions (4.6% ± 0.6% and 5.6% ± 0.6%, respectively) and those for the distal region were also greatest for the anterior to midline regions (4.4% ± 0.2% and 5.3% ± 0.2%, respectively). The largest mean strain for the proximal region was at the anterior layer (7.5% ± 1.1%) and that for the distal tendon region was at the posterior layer (7.9% ± 0.9%). This study shows significant regional differences in strain during ramped isometric contractions for the patellar tendon. Lower proximal strains in the posterior tendon compared to the anterior region may be associated with the suggestion of "stress shielding" as an etiological factor in insertional tendinopathy.

  3. Gracilis tendon transfer associated with distal alignment for patella alta with recurrent dislocations: an original surgical technique.

    PubMed

    Marteau, E; Burdin, P; Brilhault, J-M

    2011-06-01

    Many surgical techniques for the medial patellofemoral ligament have recently been suggested, all of which included problems identifying the femoral anchorage point and determining the proper extent of knee flexion for the transplant. P. Burdin proposed a different and original approach consisting in performing a gracilis muscle transfer to the medial edge of the patella, thus obtaining progressive tension of the transfer during knee flexion by means of the myotatic reflex. We report the results herein. We retrospectively assessed 17 knees treated for patellofemoral instability using this technique. Two cases presented subjective patellofemoral instability and 15 presented objective patellofemoral instability. The patients' mean age was 17.4 years (range, 8-47 years) during the first episode of dislocation. Two cases of instability were secondary to advanced neuromuscular disease. Two knees had already undergone two stabilization attempts. Fifteen knees presented trochlear dysplasia (four stage A, eight stage B, and three stage C). The mean age at surgery was 28.2 years (range, 16-47 years). In 15 cases, the gracilis transfer was associated with lowering the anterior tibial tuberosity (mean, 10mm). No patellar fracture occurred. A persistent sensory deficit of the anterior branch of the internal saphenous nerve was observed in 15 cases. One knee remained painful and retained subjective instability; total knee arthroplasty was performed 3 years after the intervention. The mean follow-up at revision was 5.5 years (range, 1.5-16.5 years). No recurrence of dislocation was reported. Eight cases retained subjective instability. The SF-36 and IKDC scores were good or excellent in 12 cases and the KOOS was good or excellent in 13 cases. Radiologically, patellar tilt persisted in six cases out of 14, translation persisted in two cases out of 14, and secondary patella baja was observed in one. Medial patellofemoral osteoarthritis was observed in five cases: one case IWANO

  4. The reliability of four widely used patellar height ratios.

    PubMed

    van Duijvenbode, Dennis; Stavenuiter, Michel; Burger, Bart; van Dijke, Cees; Spermon, Jacco; Hoozemans, Marco

    2016-03-01

    The objective of this study was to evaluate the inter-observer reliability and the intra-observer reliability of four patellar height ratios: Insall-Salvati (IS), modified Insall-Salvati (MIS), Blackburne-Peel (BP) and Caton-Deschamps (CD). The patellar height ratios were assessed by four independent examiners using weight-bearing lateral knee radiographs in 30° flexion. Intra-class correlation coefficients and Fleiss' kappa's were determined. The inter-observer reliability was excellent for the IS and moderate for the other ratios. When the ratio values were categorized, the inter-observer reliability was strong for the IS, moderate for the MIS and BP, and poor for the CD. The intra-observer reliability was excellent for the IS, MIS and CD, and strong for the BP. When the ratio values were categorized, the intra-observer reliability was strong for the IS and MIS, and moderate for the other ratios. Although the IS showed best reliability, we advise to use the MIS as it showed the second best reliability but is, according to the literature, associated with better validity.

  5. Thirteen-year outcomes in the Anatomique Benoist Girard II hip prosthesis.

    PubMed

    Catanach, Michael J M; Sorial, Rami M; Eslick, Guy D

    2015-04-01

    The Stryker Anatomique Benoist Girard (ABG) hip implant system was a commonly used cementless prosthesis in the early 2000s, which fell from favour after several studies emerged implicating the prosthesis in high rates of revision. This retrospective, single-surgeon clinical study examines the fracture rate, revision rate and reasons for revision in 500 consecutive ABG II primary total conventional hip replacements. Follow-up was conducted by audit of patient notes, patient mailout survey, patient phone contact and audit of the Australian National Joint Replacement Registry (NJRR) database to find instances of fracture and revision. End points were periprosthetic fracture and revision for any reason. Follow-up was 1.2-13.8 years with a mean of 6.58 years. Of the 500 hips, 17 (3.4%) had undergone a revision. Of these, 13 were due to periprosthetic fracture. Four further fractures occurred that were not revised. Eight of these periprosthetic fractures occurred within 1 year post-operatively. There were four revisions for recurrent dislocations. Kaplan-Meier survival curve demonstrates a 93.7% survivorship at 6.58 years for revision for any reason. Multivariate analysis showed the only statistically significant factor for increased risk of revision was smaller stem size. Our results were consistent with the literature in that the ABG II system has good medium-term results but is prone to periprosthetic fractures, especially in the early post-operative period. When used as a primary total hip arthroplasty, the ABG II system has an 8-year revision rate of 5.6% compared with the 4.9% of all primary total hip arthroplasties. © 2014 Royal Australasian College of Surgeons.

  6. 21 CFR 878.3590 - Ear prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ear prosthesis. 878.3590 Section 878.3590 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3590 Ear prosthesis. (a) Identification. An...

  7. 21 CFR 878.3590 - Ear prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Ear prosthesis. 878.3590 Section 878.3590 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3590 Ear prosthesis. (a) Identification. An...

  8. 21 CFR 878.3590 - Ear prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ear prosthesis. 878.3590 Section 878.3590 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3590 Ear prosthesis. (a) Identification. An...

  9. 21 CFR 878.3590 - Ear prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Ear prosthesis. 878.3590 Section 878.3590 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3590 Ear prosthesis. (a) Identification. An...

  10. 21 CFR 878.3590 - Ear prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Ear prosthesis. 878.3590 Section 878.3590 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3590 Ear prosthesis. (a) Identification. An...

  11. PT-12, a putative ras-activated proliferation-dependent gene, is expressed in patellar tendon and not in anterior cruciate ligament.

    PubMed

    Goomer, R S; Maris, T; Ostrander, R; Amiel, D

    1999-09-01

    We describe a gene (PT-12) that is expressed in the patellar tendon and not in the anterior cruciate ligament. We used a recently developed polymerase chain reaction-based subtractive cDNA analysis to discover genes that are overexpressed in the patellar tendon but not expressed in the anterior cruciate ligament; the long-term objective was to find genes that are central to the self-repair of the patellar tendon, in contrast with the inability of the anterior cruciate ligament to launch a repair response following injury. PT-12 is a homologue of human S2 or mouse LLRep3 ribosomal genes, which are known to be overexpressed in highly proliferating cells. This study opens a new vista to the development of techniques and reagents to study the differences between two periarticular tissues (i.e., the patellar tendon and anterior cruciate ligament) that differ primarily in their ability to self-repair.

  12. Dislocations in bilayer graphene

    NASA Astrophysics Data System (ADS)

    Butz, Benjamin; Dolle, Christian; Niekiel, Florian; Weber, Konstantin; Waldmann, Daniel; Weber, Heiko B.; Meyer, Bernd; Spiecker, Erdmann

    2014-01-01

    Dislocations represent one of the most fascinating and fundamental concepts in materials science. Most importantly, dislocations are the main carriers of plastic deformation in crystalline materials. Furthermore, they can strongly affect the local electronic and optical properties of semiconductors and ionic crystals. In materials with small dimensions, they experience extensive image forces, which attract them to the surface to release strain energy. However, in layered crystals such as graphite, dislocation movement is mainly restricted to the basal plane. Thus, the dislocations cannot escape, enabling their confinement in crystals as thin as only two monolayers. To explore the nature of dislocations under such extreme boundary conditions, the material of choice is bilayer graphene, the thinnest possible quasi-two-dimensional crystal in which such linear defects can be confined. Homogeneous and robust graphene membranes derived from high-quality epitaxial graphene on silicon carbide provide an ideal platform for their investigation. Here we report the direct observation of basal-plane dislocations in freestanding bilayer graphene using transmission electron microscopy and their detailed investigation by diffraction contrast analysis and atomistic simulations. Our investigation reveals two striking size effects. First, the absence of stacking-fault energy, a unique property of bilayer graphene, leads to a characteristic dislocation pattern that corresponds to an alternating ABAC change of the stacking order. Second, our experiments in combination with atomistic simulations reveal a pronounced buckling of the bilayer graphene membrane that results directly from accommodation of strain. In fact, the buckling changes the strain state of the bilayer graphene and is of key importance for its electronic properties. Our findings will contribute to the understanding of dislocations and of their role in the structural, mechanical and electronic properties of bilayer and

  13. Dislocations in bilayer graphene.

    PubMed

    Butz, Benjamin; Dolle, Christian; Niekiel, Florian; Weber, Konstantin; Waldmann, Daniel; Weber, Heiko B; Meyer, Bernd; Spiecker, Erdmann

    2014-01-23

    Dislocations represent one of the most fascinating and fundamental concepts in materials science. Most importantly, dislocations are the main carriers of plastic deformation in crystalline materials. Furthermore, they can strongly affect the local electronic and optical properties of semiconductors and ionic crystals. In materials with small dimensions, they experience extensive image forces, which attract them to the surface to release strain energy. However, in layered crystals such as graphite, dislocation movement is mainly restricted to the basal plane. Thus, the dislocations cannot escape, enabling their confinement in crystals as thin as only two monolayers. To explore the nature of dislocations under such extreme boundary conditions, the material of choice is bilayer graphene, the thinnest possible quasi-two-dimensional crystal in which such linear defects can be confined. Homogeneous and robust graphene membranes derived from high-quality epitaxial graphene on silicon carbide provide an ideal platform for their investigation. Here we report the direct observation of basal-plane dislocations in freestanding bilayer graphene using transmission electron microscopy and their detailed investigation by diffraction contrast analysis and atomistic simulations. Our investigation reveals two striking size effects. First, the absence of stacking-fault energy, a unique property of bilayer graphene, leads to a characteristic dislocation pattern that corresponds to an alternating AB B[Symbol: see text]AC change of the stacking order. Second, our experiments in combination with atomistic simulations reveal a pronounced buckling of the bilayer graphene membrane that results directly from accommodation of strain. In fact, the buckling changes the strain state of the bilayer graphene and is of key importance for its electronic properties. Our findings will contribute to the understanding of dislocations and of their role in the structural, mechanical and electronic

  14. Posterior approach and dislocation rate: a 213 total hip replacements case-control study comparing the dual mobility cup with a conventional 28-mm metal head/polyethylene prosthesis.

    PubMed

    Bouchet, R; Mercier, N; Saragaglia, D

    2011-02-01

    Dislocation is a frequent complication of total hip arthroplasties (THA) especially in older patients, especially when using a posterior approach. In these cases, dual mobility (DM) cups developed by Gilles Bousquet in 1975 can be indicated to reduce this complication risk. Dual mobility cups reduce the rate of dislocation in primary total hip arthroplasty using posterior approach in a single-surgeon series. Test this hypothesis in a controlled study to compare the rate of dislocation in primary total hip arthroplasties done in patients over 50 years old either with a dual mobility cup or a conventional metal-on-polyethylene 28-mm diameter head. Two consecutive series of primary total hip replacements were performed by a single surgeon using a posterolateral approach. The piriformis tendon was left intact. The DM series included 105 patients who underwent arthroplasty between January 2005 and June 2007 with a dual mobility cup (60 women and 45 men, mean age 76.6±5.65 years old [53-93]). The control series (S series) included 108 patients who underwent arthroplasty (56 women and 52 men, mean age 74.2±5.9 years old [53-87]) with a conventional 28-mm polyethylene cup between January 2003 and June 2005. All hip replacements included a 28-mm metal-polyethylene cup and a 12-14-mm Morse taper. Both groups were comparable for gender, diagnosis, body mass index, type of anesthesia and ASA score distribution. All patients included in this series had a minimum follow-up of 1 year. There were no dislocations in the DM series and five early dislocations (before the third month) in the S series for a rate of 4.63%. Although the rate of dislocation was higher in the S series (4.63% vs 0%), the difference was barely significant (P=0.0597). This study comparing the incidence of dislocations after THA with conventional or dual mobility cups, shows that even using a posterior approach and in older patients, dual mobility cups increase stability with no postoperative dislocations

  15. Diagnosis and Characterization of Patellofemoral Instability: Review of Available Imaging Modalities.

    PubMed

    Haj-Mirzaian, Arya; Thawait, Gaurav K; Tanaka, Miho J; Demehri, Shadpour

    2017-06-01

    Patellofemoral instability (PI) is defined as single or multiple episodes of patellar dislocation. Imaging modalities are useful for characterization of patellar malalignment, maltracking, underlying morphologic abnormalities, and stabilizing soft-tissue injuries. Using these findings, orthopedic surgeons can decide when to operate, determine the best operation, and measure degree of correction postoperatively in PI patients. Also, these methods assist with PI diagnosis in some suspicious cases. Magnetic resonance imaging is the preferred method especially in the setting of acute dislocations. Multidetector computed tomography allows a more accurate assessment for malalignment such as patellar tilt and lateral subluxation and secondary osteoarthritis. Dynamic magnetic resonance imaging and 4-dimensional computed tomography have been introduced for better kinematic assessment of the patellofemoral maltracking during extension-flexion motions. In this review article, we will discuss the currently available evidence regarding both the conventional and the novel imaging modalities that can be used for diagnosis and characterization of PI.

  16. Effects of dislocations on polycrystal anelasticity

    NASA Astrophysics Data System (ADS)

    Sasaki, Y.; Takei, Y.; McCarthy, C.; Suzuki, A.

    2017-12-01

    Effects of dislocations on the seismic velocity and attenuation have been poorly understood, because only a few experimental studies have been performed [Guéguen et al., 1989; Farla et al., 2012]. By using organic borneol as a rock analogue, we measured dislocation-induced anelasticity accurately over a broad frequency range. We first measured the flow law of borneol aggregates by uniaxial compression tests under a confining pressure of 0.8 MPa. A transition from diffusion creep (n = 1) to dislocation creep (n = 5) was captured at about σ = 1 MPa (40°C-50°C). After deforming in the dislocation creep regime, sample microstructure showed irregular grain shape consistent with grain boundary migration. Next, we conducted three creep tests at σ = 0.27 MPa (diffusion creep regime), σ = 1.3 MPa and σ = 1.9 MPa (dislocation creep regime) on the same sample in increasing order, and measured Young's modulus E and attenuation Q-1 after each creep test by forced oscillation tests. The results show that as σ increased, E decreased and Q-1 increased. These changes induced by dislocations, however, almost fully recovered during the forced oscillation tests performed for about two weeks under a small stress (σ = 0.27 MPa) due to the dislocation recovery (annihilation). In order to constrain the time scale of the dislocation-induced anelastic relaxation, we further measured Young's modulus E at ultrasonic frequency before and after the dislocation creep and found that E at 106 Hz is not influenced by dislocations. Because E at 100 Hz is reduced by dislocations by 10%, the dislocation-induced anelastic relaxation occurs mostly between 102-106 Hz which is at a higher frequency than grain-boundary-induced anelasticity. To avoid dislocation recovery during the anelasticity measurement, we are now trying to perform an in-situ measurement of anelasticity while simultaneously deforming under a high stress associated with dislocation creep. The combination of persistent creep

  17. The "caviar" madreporic knee prosthesis.

    PubMed

    Kenesi, C

    1979-01-01

    The madreporic ("caviar") prosthesis is a hinged knee prosthesis that can be inserted without the use of cement. The surfaces of the intramedullary stems are constructed with contiguous spheres one mm in diameter. These spaces are filled by bone trabeculae and haversian bone, providing permanent biologic fixation. Experimental madreporic knee arthroplasties in dogs show that bone probes these surfaces and produces solid attachments. Histologically, the trabeculae remain separated from the metal by a fine layer of fibrous tissue. The method of insertion of the prosthesis is simple. Preparing the epiphyses before any bone resection avoids the possibility of rotational positioning errors. The form of the intramedullary stems offers good positioning in the frontal plane. The analysis of an initial series of 15 cases shows results that are far from outstanding. The 2 deaths, the 2 cases of sepsis, and the recuperation of only mediocre motion can be explained, at least in part, by the advanced age of the patients and the poor bone quality of the rheumatoid patients. Nevertheless, this type of prosthesis has 2 important advantages. It avoids the complications from the use of acrylic cement and allows for a revision operation for cases of failed surface replacement designs. Obviously further experimentation with noncemented designs will continue and definitive studies will be reported later.

  18. 21 CFR 888.3230 - Finger joint polymer constrained prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Finger joint polymer constrained prosthesis. 888... SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3230 Finger joint polymer constrained prosthesis. (a) Identification. A finger joint polymer constrained prosthesis is a device intended...

  19. 21 CFR 888.3780 - Wrist joint polymer constrained prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint polymer constrained prosthesis. 888... SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3780 Wrist joint polymer constrained prosthesis. (a) Identification. A wrist joint polymer constrained prosthesis is a device made of...

  20. 21 CFR 888.3230 - Finger joint polymer constrained prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Finger joint polymer constrained prosthesis. 888... SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3230 Finger joint polymer constrained prosthesis. (a) Identification. A finger joint polymer constrained prosthesis is a device intended...

  1. 21 CFR 888.3780 - Wrist joint polymer constrained prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Wrist joint polymer constrained prosthesis. 888... SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3780 Wrist joint polymer constrained prosthesis. (a) Identification. A wrist joint polymer constrained prosthesis is a device made of...

  2. 21 CFR 888.3780 - Wrist joint polymer constrained prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Wrist joint polymer constrained prosthesis. 888... SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3780 Wrist joint polymer constrained prosthesis. (a) Identification. A wrist joint polymer constrained prosthesis is a device made of...

  3. 21 CFR 888.3230 - Finger joint polymer constrained prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Finger joint polymer constrained prosthesis. 888... SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3230 Finger joint polymer constrained prosthesis. (a) Identification. A finger joint polymer constrained prosthesis is a device intended...

  4. 21 CFR 888.3780 - Wrist joint polymer constrained prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Wrist joint polymer constrained prosthesis. 888... SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3780 Wrist joint polymer constrained prosthesis. (a) Identification. A wrist joint polymer constrained prosthesis is a device made of...

  5. 21 CFR 888.3230 - Finger joint polymer constrained prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Finger joint polymer constrained prosthesis. 888... SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3230 Finger joint polymer constrained prosthesis. (a) Identification. A finger joint polymer constrained prosthesis is a device intended...

  6. 21 CFR 888.3780 - Wrist joint polymer constrained prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Wrist joint polymer constrained prosthesis. 888... SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3780 Wrist joint polymer constrained prosthesis. (a) Identification. A wrist joint polymer constrained prosthesis is a device made of...

  7. 21 CFR 888.3230 - Finger joint polymer constrained prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Finger joint polymer constrained prosthesis. 888... SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3230 Finger joint polymer constrained prosthesis. (a) Identification. A finger joint polymer constrained prosthesis is a device intended...

  8. Development and clinical application of a new testicular prosthesis

    PubMed Central

    Ning, Ye; Cai, Zhikang; Chen, Huixing; Ping, Ping; Li, Peng; Wang, Zhong; Li, Zheng

    2011-01-01

    A new type of testicular prosthesis made of silastic with an elliptical shape to mimic a normal testis was developed by our team and submitted for patenting in China. The prosthesis was produced in different sizes to imitate the normal testis of the patient. To investigate the effects and safety of the testicular prosthesis, 20 patients receiving testicular prosthesis implantation were recruited for this study. Follow-up after 6 months revealed no complications in the patients. All the patients answered that they were satisfied with their body image and the position of the implants, 19 patients were satisfied with the size and 16 patients were satisfied with the weight. These results show that the testicular prosthesis used in this study can meet patient's expectations. Patients undergoing orchiectomy should be offered the option to receive a testicular prosthesis implantation. The dimensions and weight of the available prosthetic implants should be further addressed to improve patient satisfaction. PMID:21927041

  9. Recombination properties of dislocations in GaN

    NASA Astrophysics Data System (ADS)

    Yakimov, Eugene B.; Polyakov, Alexander Y.; Lee, In-Hwan; Pearton, Stephen J.

    2018-04-01

    The recombination activity of threading dislocations in n-GaN with different dislocation densities and different doping levels was studied using electron beam induced current (EBIC). The recombination velocity on a dislocation, also known as the dislocation recombination strength, was calculated. The results suggest that dislocations in n-GaN giving contrast in EBIC are charged and surrounded by a space charge region, as evidenced by the observed dependence of dislocation recombination strength on dopant concentration. For moderate (below ˜108 cm-2) dislocation densities, these defects do not primarily determine the average diffusion length of nonequilibrium charge carriers, although locally, dislocations are efficient recombination sites. In general, it is observed that the effect of the growth method [standard metalorganic chemical vapor deposition (MOCVD), epitaxial lateral overgrowth versions of MOCVD, and hydride vapor phase epitaxy] on the recombination activity of dislocations is not very pronounced, although the average diffusion lengths can widely differ for various samples. The glide of basal plane dislocations at room temperature promoted by low energy electron irradiation does not significantly change the recombination properties of dislocations.

  10. Femoral Prosthesis Infection by Rhodotorula mucilaginosa▿

    PubMed Central

    Savini, Vincenzo; Sozio, Federica; Catavitello, Chiara; Talia, Marzia; Manna, Assunta; Febbo, Fabio; Balbinot, Andrea; Di Bonaventura, Giovanni; Piccolomini, Raffaele; Parruti, Giustino; D'Antonio, Domenico

    2008-01-01

    This case report is a case history of a femoral prosthesis infection caused by Rhodotorula mucilaginosa in a human immunodeficiency virus patient. Though the pathogenicity of this organism for bone tissue has been previously reported, this is the first reported case of an orthopedic prosthesis infection by this species of the genus Rhodotorula. PMID:18753353

  11. [Classification and Treatment of Sacroiliac Joint Dislocation].

    PubMed

    Tan, Zhen; Huang, Zhong; Li, Liang; Meng, Wei-Kun; Liu, Lei; Zhang, Hui; Wang, Guang-Lin; Huang, Fu-Guo

    2017-09-01

    To develop a renewed classification and treatment regimen for sacroiliac joint dislocation. According to the direction of dislocation of sacroiliac joint,combined iliac,sacral fractures,and fracture morphology,sacroiliac joint dislocation was classified into 4 types. Type Ⅰ (sacroiliac anterior dislocation): main fracture fragments of posterior iliac wing dislocated in front of sacroiliac joint. Type Ⅱ (sacroiliac posterior dislocation): main fracture fragments of posterior iliac wing dislocated in posterior of sacroiliac joint. Type Ⅲ (Crescent fracturedislocation of the sacroiliac joint): upward dislocation of posterior iliac wing with oblique fracture through posterior iliac wing. Type ⅢA: a large crescent fragment and dislocation comprises no more than onethird of sacroiliac joint,which is typically inferior. Type ⅢB: intermediatesize crescent fragment and dislocation comprises between one and twothirds of joint. Type ⅢC: a small crescent fragment where dislocation comprises most,but not the entire joint. Different treatment regimens were selected for different types of fractures. Treatment for type Ⅰ sacroiliac joint dislocation: anterior iliac fossa approach pry stripping reset; sacroiliac joint fixed with sacroiliac screw through percutaneous. Treatment for type Ⅱ sacroiliac joint dislocation: posterior sacroiliac joint posterior approach; sacroiliac joint fixed with sacroiliac screw under computer guidance. Treatment for type ⅢA and ⅢB sacroiliac joint dislocation: posterior sacroiliac joint approach; sacroiliac joint fixed with reconstruction plate. Treatment for type ⅢC sacroiliac joint dislocation: sacroiliac joint closed reduction; sacroiliac joint fixed with sacroiliac screw through percutaneous. Treatment for type Ⅳ sacroiliac joint dislocation: posterior approach; sacroiliac joint fixed with spinal pelvic fixation. Results of 24 to 72 months patient follow-up (mean 34.5 months): 100% survival,100% wound healing,and 100

  12. Quasicontinuum analysis of dislocation-coherent twin boundary interaction to provide local rules to discrete dislocation dynamics

    NASA Astrophysics Data System (ADS)

    Tran, H.-S.; Tummala, H.; Duchene, L.; Pardoen, T.; Fivel, M.; Habraken, A. M.

    2017-10-01

    The interaction of a pure screw dislocation with a Coherent Twin Boundary Σ3 in copper was studied using the Quasicontinuum method. Coherent Twin Boundary behaves as a strong barrier to dislocation glide and prohibits slip transmission across the boundary. Dislocation pileup modifies the stress field at its intersection with the Grain Boundary (GB). A methodology to estimate the strength of the barrier for a dislocation to slip across CTB is proposed. A screw dislocation approaching the boundary from one side either propagates into the adjacent twin grain by cutting through the twin boundary or is stopped and increases the dislocation pileup amplitude at the GB. Quantitative estimation of the critical stress for transmission was performed using the virial stress computed by Quasicontinuum method. The transmission mechanism and critical stress are in line with the literature. Such information can be used as input for dislocation dynamic simulations for a better modeling of grain boundaries.

  13. Reliability of McConnell's classification of patellar orientation in symptomatic and asymptomatic subjects.

    PubMed

    Watson, C J; Propps, M; Galt, W; Redding, A; Dobbs, D

    1999-07-01

    Test-retest reliability study with blinded testers. To determine the intratester reliability of the McConnell classification system and to determine whether the intertester reliability of this system would be improved by one-on-one training of the testers, increasing the variability and numbers of subjects, blinding the testers to the absence or presence of patellofemoral pain syndrome, and adhering to the McConnell classification system as it is taught in the "McConnell Patellofemoral Treatment Plan" continuing education course. The McConnell classification system is currently used by physical therapy clinicians to quantify static patellar orientation. The measurements generated from this system purportedly guide the therapist in the application of patellofemoral tape and in assessment of the efficacy of treatment interventions on changing patellar orientation. Fifty-six subjects (age range, 21-65 years) provided a total of 101 knees for assessment. Seventy-six knees did not produce symptoms. A researcher who did not participate in the measuring process determined that 17 subjects had patellofemoral pain syndrome in 25 knees. Two testers concurrently measured static patellar orientation (anterior/posterior and medial/lateral tilt, medial/lateral glide, and patellar rotation) on subjects, using the McConnell classification system. Repeat measures were performed 3-7 days later. A kappa (kappa) statistic was used to assess the degree of agreement within each tester and between testers. The kappa coefficients for intratester reliability varied from -0.06 to 0.35. Intertester reliability ranged from -0.03 to 0.19. The McConnell classification system, in its current form, does not appear to be very reliable. Intratester reliability ranged from poor to fair, and intertester reliability was poor to slight. This system should not be used as a measurement tool or as a basis for treatment decisions.

  14. The immediate effect of patellar tendon strap on weight-bearing asymmetry during squatting in patients with unilateral knee osteoarthritis: A pilot study.

    PubMed

    Demirbüken, İlkşan; Özyürek, Seher; Angın, Salih

    2016-12-01

    Knee osteoarthritis has commonly been associated with a symptom of pain resulting in an inter-limb weight-bearing asymmetry during functional tasks. Patellar tendon strap is one of the non-pharmacologic interventions to alleviate knee pain. To investigate the immediate effect of a patellar tendon strap on weight-bearing asymmetry during squatting in people with unilateral knee osteoarthritis. Cross-sectional study. Ten patients with unilateral knee osteoarthritis and 10 healthy subjects were included in the study. Weight-bearing asymmetry of patients was assessed using a weight-bearing squat test during squatting at 30° and 60° both with and without patellar tendon strap. Pain intensity was assessed during squatting in unstrapped and strapped conditions with Visual Analog Scale. The decrease in weight-bearing asymmetry values immediately after wearing patellar tendon strap during 30° (p = 0.006) and 60° (p = 0.011) of squatting tests was significantly higher in knee osteoarthritis patients than in healthy subjects. Reported pain intensity was similar in unstrapped and strapped conditions (p = 0.066). The results of this study showed improved inter-limb weight-bearing symmetry during squatting. Further research with larger sample sizes investigating the effect of patellar tendon strap on weight-bearing asymmetry during functional activities in people with knee osteoarthritis is warranted. Patellar tendon straps (easily fit and cheap unlike knee braces) had more improvements in inter-limb weight-bearing symmetry during squatting in people with knee osteoarthritis compared to healthy subjects. This study is a new insight for future studies to investigate clinical benefits of wearing patellar tendon straps in this population. © The International Society for Prosthetics and Orthotics 2015.

  15. Landing limb posture in volleyball athletes with patellar tendinopathy: a pilot study.

    PubMed

    Kulig, K; Joiner, D G; Chang, Y-J

    2015-05-01

    The aims of this pilot study were to investigate how a novel sagittal plane kinematic measurement - the lower extremity contact angle (LECA) - relates to the landing dynamics of elite male volleyball athletes with and without patellar tendinopathy. The LECA was defined as the angle between the ground and the line connecting the center of pressure to the L5S1 marker. 18 athletes (9 with patellar tendinopathy and 9 with asymptomatic tendons) completed simulated spike jumps while instrumented for kinetic and kinematic analysis using a force platform and 3D motion analysis system. The patellar tendinopathic group demonstrated a significantly more acute LECA compared to the asymptomatic group (65.3°±2.2° vs. 69.1°±4.5°) and was the only kinematic or kinetic variable measured to discriminate between the 2 groups. The LECA further demonstrated less variability between trials than sagittal plane hip, knee, and ankle kinematics. Additionally, the LECA's - and not individual joints' - high correlation with the braking impulse ensures its predictive value for landing dynamics (r=- 0.890). The LECA has the potential to be a valuable tool to help assess jumping athletes in both injury prevention screening and as a variable that, if modified, could help alter the maladaptive behavior observed in symptomatic athletes. © Georg Thieme Verlag KG Stuttgart · New York.

  16. 21 CFR 888.3720 - Toe joint polymer constrained prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Toe joint polymer constrained prosthesis. 888.3720... (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3720 Toe joint polymer constrained prosthesis. (a) Identification. A toe joint polymer constrained prosthesis is a device made of silicone...

  17. 21 CFR 888.3720 - Toe joint polymer constrained prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Toe joint polymer constrained prosthesis. 888.3720... (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3720 Toe joint polymer constrained prosthesis. (a) Identification. A toe joint polymer constrained prosthesis is a device made of silicone...

  18. 21 CFR 888.3720 - Toe joint polymer constrained prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Toe joint polymer constrained prosthesis. 888.3720... (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3720 Toe joint polymer constrained prosthesis. (a) Identification. A toe joint polymer constrained prosthesis is a device made of silicone...

  19. 21 CFR 888.3720 - Toe joint polymer constrained prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Toe joint polymer constrained prosthesis. 888.3720... (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3720 Toe joint polymer constrained prosthesis. (a) Identification. A toe joint polymer constrained prosthesis is a device made of silicone...

  20. 21 CFR 888.3720 - Toe joint polymer constrained prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Toe joint polymer constrained prosthesis. 888.3720... (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3720 Toe joint polymer constrained prosthesis. (a) Identification. A toe joint polymer constrained prosthesis is a device made of silicone...

  1. MPR-CT Imaging for Stapes Prosthesis: Accuracy and Clinical Significance.

    PubMed

    Fang, Yanqing; Wang, Bing; Galvin, John J; Tao, Duoduo; Deng, Rui; Ou, Xiong; Liu, Yangwenyi; Dai, Peidong; Sha, Yan; Zhang, Tianyu; Chen, Bing

    2016-04-01

    The aims of this article are: 1) to re-evaluate the accuracy of multiple planar reconstruction computed tomography (MPR-CT) imaging on stapes-prosthesis parameters, and 2) to clarify possible relationships between prosthesis intravestibular depth and postoperative hearing outcomes. Seventy patients (46 women and 24 men; 32 right and 38 left sides) with the mean age of 40 years (range, 19-62 yr) with clinical otosclerosis. All patients underwent stapedotomy and were implanted with the same type of titanium piston prosthesis by the same surgeon. Postoperative MPR-CTs were obtained at patients' follow-up visits. The length and intravestibular depth of the stapes prosthesis (including absolute and relative depth) were calculated from the MPR-CT imaging. Relationships between the intravestibular depth of the prosthesis and hearing outcomes (pre- and postoperative audiograms) were analyzed using Spearman correlation analyses. The length of the prosthesis was overestimated by 1.8% (0.1 mm) by the MPR-CT imaging. Axial and coronal measurements were significantly correlated (p < 0.05). There was great intersubject variability in hearing outcomes differed insignificantly, regardless of intravestibular depth within the security range. No relationships were found between the intravestibular depth of the stapes prosthesis, as measured with MPR-CT, and postoperative hearing results. MPR-CT can provide an accurate estimation of stapes prosthesis parameters. However, the prosthesis intravestibular depth did not seem to affect postoperative hearing outcomes.

  2. Kinematic Analysis of a Posterior-stabilized Knee Prosthesis

    PubMed Central

    Zhao, Zhi-Xin; Wen, Liang; Qu, Tie-Bing; Hou, Li-Li; Xiang, Dong; Bin, Jia

    2015-01-01

    Background: The goal of total knee arthroplasty (TKA) is to restore knee kinematics. Knee prosthesis design plays a very important role in successful restoration. Here, kinematics models of normal and prosthetic knees were created and validated using previously published data. Methods: Computed tomography and magnetic resonance imaging scans of a healthy, anticorrosive female cadaver were used to establish a model of the entire lower limbs, including the femur, tibia, patella, fibula, distal femur cartilage, and medial and lateral menisci, as well as the anterior cruciate, posterior cruciate, medial collateral, and lateral collateral ligaments. The data from the three-dimensional models of the normal knee joint and a posterior-stabilized (PS) knee prosthesis were imported into finite element analysis software to create the final kinematic model of the TKA prosthesis, which was then validated by comparison with a previous study. The displacement of the medial/lateral femur and the internal rotation angle of the tibia were analyzed during 0–135° flexion. Results: Both the output data trends and the measured values derived from the normal knee's kinematics model were very close to the results reported in a previous in vivo study, suggesting that this model can be used for further analyses. The PS knee prosthesis underwent an abnormal forward displacement compared with the normal knee and has insufficient, or insufficiently aggressive, “rollback” compared with the lateral femur of the normal knee. In addition, a certain degree of reverse rotation occurs during flexion of the PS knee prosthesis. Conclusions: There were still several differences between the kinematics of the PS knee prosthesis and a normal knee, suggesting room for improving the design of the PS knee prosthesis. The abnormal kinematics during early flexion shows that the design of the articular surface played a vital role in improving the kinematics of the PS knee prosthesis. PMID:25591565

  3. Kinematic analysis of a posterior-stabilized knee prosthesis.

    PubMed

    Zhao, Zhi-Xin; Wen, Liang; Qu, Tie-Bing; Hou, Li-Li; Xiang, Dong; Bin, Jia

    2015-01-20

    The goal of total knee arthroplasty (TKA) is to restore knee kinematics. Knee prosthesis design plays a very important role in successful restoration. Here, kinematics models of normal and prosthetic knees were created and validated using previously published data. Computed tomography and magnetic resonance imaging scans of a healthy, anticorrosive female cadaver were used to establish a model of the entire lower limbs, including the femur, tibia, patella, fibula, distal femur cartilage, and medial and lateral menisci, as well as the anterior cruciate, posterior cruciate, medial collateral, and lateral collateral ligaments. The data from the three-dimensional models of the normal knee joint and a posterior-stabilized (PS) knee prosthesis were imported into finite element analysis software to create the final kinematic model of the TKA prosthesis, which was then validated by comparison with a previous study. The displacement of the medial/lateral femur and the internal rotation angle of the tibia were analyzed during 0-135° flexion. Both the output data trends and the measured values derived from the normal knee's kinematics model were very close to the results reported in a previous in vivo study, suggesting that this model can be used for further analyses. The PS knee prosthesis underwent an abnormal forward displacement compared with the normal knee and has insufficient, or insufficiently aggressive, "rollback" compared with the lateral femur of the normal knee. In addition, a certain degree of reverse rotation occurs during flexion of the PS knee prosthesis. There were still several differences between the kinematics of the PS knee prosthesis and a normal knee, suggesting room for improving the design of the PS knee prosthesis. The abnormal kinematics during early flexion shows that the design of the articular surface played a vital role in improving the kinematics of the PS knee prosthesis.

  4. The prevalence of Achilles and patellar tendon injuries in Australian football players beyond a time-loss definition.

    PubMed

    Docking, S I; Rio, E; Cook, J; Orchard, J W; Fortington, L V

    2018-03-23

    Little is known about the prevalence and associated of morbidity of tendon problems. With only severe cases of tendon problems missing games, players that have their training and performance impacted are not captured by traditional injury surveillance. The aim of this study was to report the prevalence of Achilles and patellar tendon problems in elite male Australian football players using the Oslo Sports Trauma Research Centre (OSTRC) overuse questionnaire, compared to a time-loss definition. Male athletes from 12 professional Australian football teams were invited to complete a monthly questionnaire over a 9-month period in the 2016 pre- and competitive season. The OSTRC overuse injury questionnaire was used to measure the prevalence and severity of Achilles and patellar tendon symptoms and was compared to traditional match-loss statistics. A total of 441 participants were included. Of all participants, 21.5% (95% CI: 17.9-25.6) and 25.2% (95% CI 21.3-29.4) reported Achilles or patellar tendon problems during the season, respectively. Based on the traditional match-loss definition, a combined 4.1% of participants missed games due to either Achilles or patellar tendon injury. A greater average monthly prevalence was observed during the pre-season compared to the competitive season. Achilles and patellar tendon problems are prevalent in elite male Australian football players. These injuries are not adequately captured using a traditional match-loss definition. Prevention of these injuries may be best targeted during the off- and pre-season due to higher prevalence of symptoms during the pre-season compared to during the competitive season. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Patellar Tendon Repair Augmentation With a Knotless Suture Anchor Internal Brace: A Biomechanical Cadaveric Study.

    PubMed

    Rothfeld, Alex; Pawlak, Amanda; Liebler, Stephenie A H; Morris, Michael; Paci, James M

    2018-04-01

    Patellar tendon repair with braided polyethylene suture alone is subject to knot slippage and failure. Several techniques to augment the primary repair have been described. Purpose/Hypothesis: The purpose was to evaluate a novel patellar tendon repair technique augmented with a knotless suture anchor internal brace with suture tape (SAIB). The hypothesis was that this technique would be biomechanically superior to a nonaugmented repair and equivalent to a standard augmentation with an 18-gauge steel wire. Controlled laboratory study. Midsubstance patellar tendon tears were created in 32 human cadaveric knees. Two comparison groups were created. Group 1 compared #2 supersuture repair without augmentation to #2 supersuture repair with SAIB augmentation. Group 2 compared #2 supersuture repair with an 18-gauge stainless steel cerclage wire augmentation to #2 supersuture repair with SAIB augmentation. The specimens were potted and biomechanically loaded on a materials testing machine. Yield load, maximum load, mode of failure, plastic displacement, elastic displacement, and total displacement were calculated for each sample. Standard statistical analysis was performed. There was a statistically significant increase in the mean ± SD yield load and maximum load in the SAIB augmentation group compared with supersuture alone (mean yield load: 646 ± 202 N vs 229 ± 60 N; mean maximum load: 868 ± 162 N vs 365 ± 54 N; P < .001). Group 2 showed no statistically significant differences between the augmented repairs (mean yield load: 495 ± 213 N vs 566 ± 172 N; P = .476; mean maximum load: 737 ± 210 N vs 697 ± 130 N; P = .721). Patellar tendon repair augmented with SAIB is biomechanically superior to repair without augmentation and is equivalent to repair with augmentation with an 18-gauge stainless steel cerclage wire. This novel patellar tendon repair augmentation is equivalent to standard 18-gauge wire augmentation at time zero. It does not require a second surgery for

  6. Prosthetic management of mid-facial defect with magnet-retained silicone prosthesis.

    PubMed

    Buzayan, Muaiyed M

    2014-02-01

    Mid-facial defect is one of the most disfiguring and impairing defects. A design of prosthesis that is aesthetic and stable can be precious to a patient who has lost part of his face due to surgical excision. Prosthesis can restore the patients' self-esteem and confidence, which affects the patients and their life style. The aim of this case report is to describe a technique of mid-facial silicone prosthesis fabrication. To provide an aesthetic and stable facial prosthesis, the extra-oral prosthesis was fabricated using silicone material, while the intra-oral defect was restored with obturator prosthesis, and then both prostheses were connected and attached to each other using magnets. This clinical report describes the rehabilitation of a large mid-facial defect with a two-piece prosthesis. The silicone facial prosthesis was made hollow and lighter by using an acrylic framework. Two acrylic channels were included within the facial prosthesis to provide the patient with clean and patent airways. A sectional mid-facial prosthesis was made and retained in place by using magnets, which resulted in a significant improvement in the aesthetical and functional outcome without the need for plastic surgery. Silicone prostheses are reliable alternatives to surgery and should be considered in selected cases.

  7. Fast Fourier transform discrete dislocation dynamics

    NASA Astrophysics Data System (ADS)

    Graham, J. T.; Rollett, A. D.; LeSar, R.

    2016-12-01

    Discrete dislocation dynamics simulations have been generally limited to modeling systems described by isotropic elasticity. Effects of anisotropy on dislocation interactions, which can be quite large, have generally been ignored because of the computational expense involved when including anisotropic elasticity. We present a different formalism of dislocation dynamics in which the dislocations are represented by the deformation tensor, which is a direct measure of the slip in the lattice caused by the dislocations and can be considered as an eigenstrain. The stresses arising from the dislocations are calculated with a fast Fourier transform (FFT) method, from which the forces are determined and the equations of motion are solved. Use of the FFTs means that the stress field is only available at the grid points, which requires some adjustments/regularizations to be made to the representation of the dislocations and the calculation of the force on individual segments, as is discussed hereinafter. A notable advantage of this approach is that there is no computational penalty for including anisotropic elasticity. We review the method and apply it in a simple dislocation dynamics calculation.

  8. Do peak torque angles of muscles change following anterior cruciate ligament reconstruction using hamstring or patellar tendon graft?

    PubMed

    Yosmaoğlu, Hayri Baran; Baltacı, Gül; Sönmezer, Emel; Özer, Hamza; Doğan, Deha

    2017-12-01

    This study aims to compare the effects of anterior cruciate ligament (ACL) reconstruction using autogenous hamstring or patellar tendon graft on the peak torque angle. The study included 132 patients (103 males, 29 females; mean age 29±9 year) who were performed ACL reconstruction with autogenous hamstring or patellar tendon graft. The peak torque angles in the quadriceps and hamstring muscles were recorded using an isokinetic dynamometer. Angle of peak knee flexion torque occurred significantly earlier within the range of motion on the operated side than nonoperated side at 180°/second in the hamstring tendon group. Angle of peak knee extension torque occurred significantly earlier within the range of motion on the operated side than nonoperated side at 180°/second in the patellar tendon group. There were no statistically significant differences in the flexion and extension peak torque angles between the operated and nonoperated knees at 60°/second in both groups. The angle of peak torque at relatively high angular velocities is affected after ACL reconstruction in patients with hamstring or patellar tendon grafts. The graft donor site directly influences this parameter. This finding may be important for clinicians in terms of preventing re-injury.

  9. A Novel Thermal-activated Shape Memory Penile Prosthesis: Comparative Mechanical Testing.

    PubMed

    Le, Brian; McVary, Kevin; McKenna, Kevin; Colombo, Alberto

    2017-01-01

    To compare a novel nickel-titanium (Ni-Ti) shape memory alloy (SMA) penile prosthesis of our own design with commercially available prostheses using a format similar to mechanical testing done at major penile prosthesis manufacturers. We evaluated the mechanical parameters of commercially available penile prostheses and used this information to guide the development of the Ni-Ti-based physiological penile prosthesis that expands and becomes erect with a small amount of heat applied. A penile prosthesis consisting of an exoskeleton of temperature-tuned Nitinol was designed and prototyped. Mechanical testing was performed in a model of penile buckling, penile lateral deviation, and original penile shape recovery commonly used by penile prosthesis manufacturers for testing. Our SMA penile prosthesis demonstrated useful mechanical characteristics, including rigidity to buckling when activated similar to an inflatable penile prosthesis (2.62 kgf SMA vs 1.42 kgf inflatable penile prosthesis vs 6.45 kgf for a malleable prosthesis). The Ni-Ti also became more pliable when deactivated within acceptable mechanical ranges of existing devices. It could be repeatedly cycled and generate a restorative force to become erect. An SMA-based penile prosthesis represents a promising new technology in the treatment of erectile dysfunction. We demonstrated that an Ni-Ti-based prosthesis can produce the mechanical forces necessary for producing a simulated erection without the need for a pump or reservoir, comparable with existing prostheses. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Active upper limb prosthesis based on natural movement trajectories.

    PubMed

    Ramírez-García, Alfredo; Leija, Lorenzo; Muñoz, Roberto

    2010-03-01

    The motion of the current prostheses is sequential and does not allow natural movements. In this work, complex natural motion patterns from a healthy upper limb were characterized in order to be emulated for a trans-humeral prosthesis with three degrees of freedom at the elbow. Firstly, it was necessary to define the prosthesis workspace, which means to establish a relationship using an artificial neural network (ANN), between the arm-forearm (3-D) angles allowed by the prosthesis, and its actuators length. The 3-D angles were measured between the forearm and each axis of the reference system attached at the elbow. Secondly, five activities of daily living (ADLs) were analyzed by means of the elbow flexion (EF), the forearm prono-supination (FPS) and the 3-D angles, from healthy subjects, by using a video-based motion analysis system. The 3-D angles were fed to the prosthesis model (ANN) in order to analyze which ADLs could be emulated by the prosthesis. As a result, a prosthesis kinematics approximation was obtained. In conclusion, in spite of the innovative mechanical configuration of the actuators, it was possible to carry out only three of the five ADLs considered. Future work will include improvement of the mechanical configuration of the prosthesis to have greater range of motion.

  11. Superolateral Hoffa's fat pad (SHFP) oedema and patellar cartilage volume loss: quantitative analysis using longitudinal data from the Foundation for the National Institute of Health (FNIH) Osteoarthritis Biomarkers Consortium.

    PubMed

    Haj-Mirzaian, Arya; Guermazi, Ali; Hafezi-Nejad, Nima; Sereni, Christopher; Hakky, Michael; Hunter, David J; Zikria, Bashir; Roemer, Frank W; Demehri, Shadpour

    2018-04-12

    To determine the association of superolateral Hoffa's fat pad (SHFP) oedema and patellofemoral joint structural damage in participants of Foundation for the National Institute of Health Osteoarthritis Biomarkers Consortium study. Baseline and 24-month MRIs of 600 subjects were assessed. The presence of SHFP oedema (using 0-3 grading scale) and patellar morphology metrics were determined using baseline MRI. Quantitative patellar cartilage volume and semi-quantitative MRI osteoarthritis knee score (MOAKS) variables were extracted. The associations between SHFP oedema and patellar cartilage damage, bone marrow lesion (BML), osteophyte and morphology were evaluated in cross-sectional model. In longitudinal analysis, the associations between oedema and cartilage volume loss (defined using reliable change index) and MOAKS worsening were evaluated. In cross-sectional evaluations, the presence of SHFP oedema was associated with simultaneous lateral patellar cartilage/BML defects and inferior-medial patellar osteophyte size. A significant positive correlation between the degree of patella alta and SHFP oedema was detected (r = 0.259, p < 0.001). The presence of oedema was associated with 24-month cartilage volume loss (odds ratio (OR) 2.11, 95% confidence interval 1.46-3.06) and medial patellar BML size (OR 1.92 (1.15-3.21)) and number (OR 2.50 (1.29-4.88)) worsening. The optimal cut-off value for the grade of baseline SHFP oedema regarding both presence and worsening of patellar structural damage was ≥ 1 (presence of any SHFP hyperintensity). The presence of SHFP oedema could be considered as a predictor of future patellar cartilage loss and BML worsening, and an indicator of simultaneous cartilage, BML and osteophyte defects. • SHFP oedema was associated with simultaneous lateral patellar OA-related structural damage. • SHFP oedema was associated with longitudinal patellar cartilage loss over 24 months. • SHFP oedema could be considered as indicator and predictor

  12. Theory of interacting dislocations on cylinders.

    PubMed

    Amir, Ariel; Paulose, Jayson; Nelson, David R

    2013-04-01

    We study the mechanics and statistical physics of dislocations interacting on cylinders, motivated by the elongation of rod-shaped bacterial cell walls and cylindrical assemblies of colloidal particles subject to external stresses. The interaction energy and forces between dislocations are solved analytically, and analyzed asymptotically. The results of continuum elastic theory agree well with numerical simulations on finite lattices even for relatively small systems. Isolated dislocations on a cylinder act like grain boundaries. With colloidal crystals in mind, we show that saddle points are created by a Peach-Koehler force on the dislocations in the circumferential direction, causing dislocation pairs to unbind. The thermal nucleation rate of dislocation unbinding is calculated, for an arbitrary mobility tensor and external stress, including the case of a twist-induced Peach-Koehler force along the cylinder axis. Surprisingly rich phenomena arise for dislocations on cylinders, despite their vanishing Gaussian curvature.

  13. Factors affecting the outcomes of modified tension band wiring techniques in transverse patellar fractures.

    PubMed

    Hsu, Kai-Lan; Chang, Wei-Lun; Yang, Chyun-Yu; Yeh, Ming-Long; Chang, Chih-Wei

    2017-12-01

    Modified tension band wiring has been widely used to treat transverse patellar fractures. However, few studies have evaluated the clinical outcomes using different methods of Kirschner wire bending, location of the tension band, and depths of Kirschner wires. Thus, we tried to clarify these factors according to our clinical outcomes. This retrospective cohort study recruited consecutive patients underwent surgical fixation for patellar fractures using modified tension band technique between January 2010 and December 2015. Different factors in this procedure, including the bending manner of the Kirschner wires, their depth, and location of the tension band with respect to the superior and inferior border of the patella were recorded and analysed. The primary outcome was early loss of fixation. The secondary outcomes were minor loss of reduction, implant breakage, deep infection, and the need for implant removal. This study included 170 patients with patellar fractures. Regarding the bending method, similar results were obtained with bilaterally or proximally bent Kirschner wires. Regarding length, the tension band was placed closely (within 25% of the patella length) in 124 patients and distantly in 46 patients. The rates of loss of reduction and implant breakage were significantly higher in the distantly placed tension bands. Regarding depth, 37 patellar fractures were fixed with the Kirschner wires at the superficial one third of the patellae while the K- wires at the middle layer of patella were used in the remaining 133 patellar fractures. A significantly higher rate of minor loss of reduction was obtained using the superficial Kirschner wires. The modified tension band technique for transverse patella fractures provides favourable clinical outcomes, with low failure (5%) and infection (2%) rates. Implant irritation is the major complication, and almost half of cases require implant removal. The location of the tension band with respect to the superior and

  14. Patellar cartilage lesions: comparison of magnetic resonance imaging and T2 relaxation-time mapping.

    PubMed

    Hannila, I; Nieminen, M T; Rauvala, E; Tervonen, O; Ojala, R

    2007-05-01

    To evaluate the detection and the size of focal patellar cartilage lesions in T2 mapping as compared to standard clinical magnetic resonance imaging (MRI) at 1.5T. Fifty-five consecutive clinical patients referred to knee MRI were imaged both with a standard knee MRI protocol (proton-density-weighted sagittal and axial series, T2-weighted sagittal and coronal series, and T1-weighted coronal series) and with an axial multislice multi-echo spin-echo measurement to determine the T2 relaxation time of the patellar cartilage. MR images and T2 maps of patellar cartilage were evaluated for focal lesions. The lesions were evaluated for lesion width (mm), lesion depth (1/3, 2/3, or 3/3 of cartilage thickness), and T2 value (20-40 ms, 40-60 ms, or 60-80 ms) based on visual evaluation. Altogether, 36 focal patellar cartilage lesions were detected from 20 human subjects (11 male, nine female, mean age 40+/-15 years). Twenty-eight lesions were detected both on MRI and T2 maps, while eight lesions were only visible on T2 maps. Cartilage lesions were significantly wider (P = 0.001) and thicker (P<0.001) on T2 maps as compared to standard knee MRI. Most lesions 27 had moderately (T2 40-60 ms) increased T2 values, while two lesions had slightly (T2 20-40 ms) and seven lesions remarkably (T2 60-80 ms) increased T2 relaxation times. T2 mapping of articular cartilage is feasible in the clinical setting and may reveal early cartilage lesions not visible with standard clinical MRI.

  15. Dislocation pinning effects induced by nano-precipitates during warm laser shock peening: Dislocation dynamic simulation and experiments

    NASA Astrophysics Data System (ADS)

    Liao, Yiliang; Ye, Chang; Gao, Huang; Kim, Bong-Joong; Suslov, Sergey; Stach, Eric A.; Cheng, Gary J.

    2011-07-01

    Warm laser shock peening (WLSP) is a new high strain rate surface strengthening process that has been demonstrated to significantly improve the fatigue performance of metallic components. This improvement is mainly due to the interaction of dislocations with highly dense nanoscale precipitates, which are generated by dynamic precipitation during the WLSP process. In this paper, the dislocation pinning effects induced by the nanoscale precipitates during WLSP are systematically studied. Aluminum alloy 6061 and AISI 4140 steel are selected as the materials with which to conduct WLSP experiments. Multiscale discrete dislocation dynamics (MDDD) simulation is conducted in order to investigate the interaction of dislocations and precipitates during the shock wave propagation. The evolution of dislocation structures during the shock wave propagation is studied. The dislocation structures after WLSP are characterized via transmission electron microscopy and are compared with the results of the MDDD simulation. The results show that nano-precipitates facilitate the generation of highly dense and uniformly distributed dislocation structures. The dislocation pinning effect is strongly affected by the density, size, and space distribution of nano-precipitates.

  16. Clinical and biomechanical assessment of patella resurfacing in total knee arthroplasty.

    PubMed

    Berti, Lisa; Benedetti, Maria Grazia; Ensini, Andrea; Catani, Fabio; Giannini, Sandro

    2006-07-01

    Currently there is a limited understanding of the factors influencing range of motion by comparing patellar resurfacing vs non-resurfacing in total knee arthroplasty during activities of daily living. A recent meta-analysis of patellar replacement confirms better outcome with patella resurfacing; however, the result can be influenced by many other factors, such as: component design, surgeon experience, and technical aspects of the surgery. This study compares the biomechanics of the knee in patients after total knee arthroplasty with and without patellar resurfacing during stair climbing. Forty-seven patients with total knee arthroplasty were assessed at the mean follow-up of 24 months. In all of them a posterior stabilised fixed bearing prosthesis (Optetrak PS, Exactech) was implanted. Twenty-six patients were treated without patellar resurfacing and 21 with patellar resurfacing. Clinical evaluations were performed using the International Knee Society and the Hospital for Special Surgery scores. Ten patients with patellar resurfacing and 10 patients without patellar resurfacing were also studied with motion analysis during stair climbing; 10 healthy subjects were studied for statistical comparison. Clinical passive knee flexion, International Knee Society Function and Hospital for Special Surgery scores were significantly higher in the patellar resurfacing group. During stair climbing, active knee joint range of motion during the stance phase was greater in patients with patellar resurfacing. The maximum adduction moment was significantly higher in the group without patellar resurfacing. Patients with patellar resurfacing demonstrated better clinical scores, and kinematic and kinetic data while ascending stairs.

  17. 21 CFR 888.3025 - Passive tendon prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Passive tendon prosthesis. 888.3025 Section 888.3025 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3025 Passive tendon prosthesis. (a...

  18. 21 CFR 888.3025 - Passive tendon prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Passive tendon prosthesis. 888.3025 Section 888.3025 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3025 Passive tendon prosthesis. (a...

  19. 21 CFR 888.3025 - Passive tendon prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Passive tendon prosthesis. 888.3025 Section 888.3025 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3025 Passive tendon prosthesis. (a...

  20. 21 CFR 872.3960 - Mandibular condyle prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Mandibular condyle prosthesis. 872.3960 Section 872.3960 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3960 Mandibular condyle prosthesis. (a...

  1. Misfit dislocation patterns of Mg-Nb interfaces

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Youxing; Shao, Shuai; Liu, Xiang-Yang

    The role of heterogeneous interfaces in improving mechanical properties of polycrystalline aggregates and laminated composites has been well recognized with interface structure being of fundamental importance in designing composites containing multiple interfaces. In this paper, taking the Mg (hexagonal close-packed (hcp))/Nb (body-centered cubic (bcc)) interface as an example, we develop Mg-Nb interatomic potentials for predicting atomic configurations of Mg/Nb interfaces. We systematically characterize interface dislocations of Mg/Nb interfaces with Nishiyama-Wassermann (NW) and Kurdjumov-Sachs (KS) orientation relationships and propose a generalized procedure of characterizing interface structure by combining atomistic simulation and interface dislocation theory, which is applicable for not only hcp/bccmore » interfaces, but also other systems with complicated interface dislocation configurations.Here, in Mg/Nb, interface dislocation networks of two types of interfaces are significantly different although they originate from partial dislocations of similar character: the NW interface is composed of three sets of partial dislocations, while the KS interface is composed of four sets of interface dislocations - three sets of partial dislocations and one set of full dislocations that forms from the reaction of two close partial dislocations.« less

  2. Probing the character of ultra-fast dislocations

    DOE PAGES

    Rudd, R. E.; Ruestes, C. J.; Bringa, E. M.; ...

    2015-11-23

    Plasticity is often controlled by dislocation motion, which was first measured for low pressure, low strain rate conditions decades ago. However, many applications require knowledge of dislocation motion at high stress conditions where the data are sparse, and come from indirect measurements dominated by the effect of dislocation density rather than velocity. Here we make predictions based on atomistic simulations that form the basis for a new approach to measure dislocation velocities directly at extreme conditions using three steps: create prismatic dislocation loops in a near-surface region using nanoindentation, drive the dislocations with a shockwave, and use electron microscopy tomore » determine how far the dislocations moved and thus their velocity at extreme stress and strain rate conditions. We report on atomistic simulations of tantalum that make detailed predictions of dislocation flow, and find that the approach is feasible and can uncover an exciting range of phenomena, such as transonic dislocations and a novel form of loop stretching. Furthermore, the simulated configuration enables a new class of experiments to probe average dislocation velocity at very high applied shear stress.« less

  3. Categorization of compensatory motions in transradial myoelectric prosthesis users.

    PubMed

    Hussaini, Ali; Zinck, Arthur; Kyberd, Peter

    2017-06-01

    Prosthesis users perform various compensatory motions to accommodate for the loss of the hand and wrist as well as the reduced functionality of a prosthetic hand. Investigate different compensation strategies that are performed by prosthesis users. Comparative analysis. A total of 20 able-bodied subjects and 4 prosthesis users performed a set of bimanual activities. Movements of the trunk and head were recorded using a motion capture system and a digital video recorder. Clinical motion angles were calculated to assess the compensatory motions made by the prosthesis users. The video recording also assisted in visually identifying the compensations. Compensatory motions by the prosthesis users were evident in the tasks performed (slicing and stirring activities) as compared to the benchmark of able-bodied subjects. Compensations took the form of a measured increase in range of motion, an observed adoption of a new posture during task execution, and prepositioning of items in the workspace prior to initiating a given task. Compensatory motions were performed by prosthesis users during the selected tasks. These can be categorized into three different types of compensations. Clinical relevance Proper identification and classification of compensatory motions performed by prosthesis users into three distinct forms allows clinicians and researchers to accurately identify and quantify movement. It will assist in evaluating new prosthetic interventions by providing distinct terminology that is easily understood and can be shared between research institutions.

  4. [Use of Ultrasound in the Follow-up of Professional Athletes Receiving Conservative Treatment of Patellar Tendon Enthesiopathy].

    PubMed

    Guo, Li-juan; Cui, Li-gang; Li, Yu-mei; Liao, Li-ping; Song, Lin

    2015-10-01

    To investigate the role of high-frequency ultrasound (HFUS) in evaluating in the effectiveness of conservative treatment for professional athletes with patellar tendon enthesiopathy. According to different treatment intensities, 24 professional athletes with patellar tendon enthesiopathy were randomly divided into painless group, slightly-painful group and extremely-painful group. Then changes of the HFUS findings [including ranges of two-dimensional diseases and blood conditions by Color Doppler Flow Imaging (CDFI)] of patellar tendon before and after the treatment were recorded. The results were also compared with conventional clinical treatment evaluations. After two courses of treatment,the percentage of athletes whose pain was resolved or disappeared was 37.5% in painless group, 87.5% in slightly-painful group, and 62.5% in extremely-painful group. The pain score was 4.50 ± 2.07, 4.88 ± 1.13, and 6.13 ± 1.55 in painless group,slightly-painful group,and extremely-painful group, respectively,before treatment and 4.88 ± 2.17, 3.00 ± 1.77,and 5.13 ± 2.36 after treatment. The average pain score remarkably decreased in the slightly-painful group and extremely-painful group,and such difference was statistically significant in the slightly-pain group (P<0.05). The effective rate (defined as thinner patellar,decreased hypoecho area and fewer blood distribution in the lesion) was 38%, 50%, and 62% in the painless group, slightly-painful group,and extremely-painful group, and the rates in the slightly-painful group and extremely-painful group were significantly higher than that in painless group (both P<0.05). HFUS can display the ultrasonographic changes of patellar tendon enthesiopathy after conservative treatments in an objective and quantitative manner. Compared with conventional clinical evaluations, it can more accurately reflect the disease recovery status.

  5. Hearing results using the SMart piston prosthesis.

    PubMed

    Fayad, Jose N; Semaan, Maroun T; Meier, Josh C; House, John W

    2009-12-01

    SMart, a newly introduced piston prosthesis for stapedotomy, is a nitinol-based, heat-activated, self-crimping prosthesis. We review our hearing results and postoperative complications using this self-crimped piston prosthesis and compare them with those obtained using stainless steel or platinum piston prostheses. Audiometric results using the SMart piston are identical to those obtained using a conventional piston prosthesis. Retrospective chart review. Private neurotologic tertiary referral center. The 416 ears reviewed included 306 with a SMart prosthesis and 110 conventional prostheses. 61% were women. Mean follow-up time was 5.6 (standard deviation [SD], 6.3 mo) and 6.9 months (SD, 7.0 mo) for the 2 groups, respectively. Stapedotomy using the SMart or a conventional (non-SMart) prosthesis. Audiometric hearing results, including pure-tone average (PTA) and air-bone gap (ABG), and prevalence of postoperative complications. Mean postoperative PTA was 32.6 (SD, 16.8) dB for the SMart group and 29.4 (SD, 13.5) dB for the non-SMart group, with ABGs of 7.6 (SD, 8.9) and 6.0 (SD, 5.2) dB, respectively. Mean change (decrease) in ABG was 18.7 (SD, 13.1) dB for the SMart group and 19.9 (SD, 10.3) dB for the non-SMart group. High-frequency bone PTAs showed overclosure of 2.0 (SD, 7.9) dB for the SMart group and 3.6 (SD, 8.6) dB for the non-SMart group. Postoperative vertigo and tinnitus were infrequent. No significant differences in these audiometric outcomes or complication rates were noted between groups. There was no significant difference in rate of gap closure to within 10 dB (78.3 versus 84.2%, SMart and non-SMart, respectively) or 20 dB (94.2 and 98.0%). Compared with conventional stapes prostheses, the nitinol-based SMart is a safe and reliable stapes prosthesis that eliminates manual crimping without significantly altering the audiometric outcome. Complications are rare, but longer follow-up is needed before establishing long-term stability.

  6. Hyaluronic acid injections protect patellar tendon from detraining-associated damage.

    PubMed

    Frizziero, Antonio; Salamanna, Francesca; Giavaresi, Gianluca; Ferrari, Andrea; Martini, Lucia; Marini, Marina; Veicsteinas, Arsenio; Maffulli, Nicola; Masiero, Stefano; Fini, Milena

    2015-09-01

    Having previously demonstrated that detraining affects patellar tendon (PT) proteoglycan content and collagen fiber organization, we undertook the present study with two aims: to improve knowledge on the adaptation of PT and its enthesis to detraining from a histological and histomorphometric point of view, and to investigate the hypothesis that repeated peri-patellar injections of hyaluronic acid (HA) on detrained PT may reduce and limit detrained associated-damage. Twenty-four male Sprague-Dawley rats were divided into 3 groups: Untrained (n=6), Trained (n=6) (10 wks-treadmill) and Detrained (n=12). In the detrained rats, the left tendon was untreated while the right tendon received repeated peri-patellar injections of either HA or saline (NaCl). Structure and morphology of PTs (modified Movin score, tear density, collagen type I and III) and enthesis (cell morphology, chondrocyte cluster formation, tidemark integrity, matrix staining and vascularization) were evaluated. The left PT and enthesis of the Detrained groups showed altered structure and morphology with the highest Movin score values, the highest percentage of collagen III and the lowest of collagen I; the lowest score values were observed in the Trained and Detrained-HA groups. Detrained-NaCl PTs showed the highest collagen III and the lowest collagen I values with respect to Detrained-HA PTs. This study strengthens previously published data showing the alteration in tendon and enthesis morphology due to discontinuation of training, and provides new data showing that treatment with HA is effective in the maintenance of the structural properties of PT and enthesis in Detrained rats. Such beneficial effects could play a significant role in the management of conservative and rehabilitation strategies in athletes that change type, intensity and duration of training.

  7. Pelvic reconstructions following peri-acetabular bone tumour resections using a cementless ice-cream cone prosthesis with dual mobility cup.

    PubMed

    Issa, Samir-Pierre; Biau, David; Babinet, Antoine; Dumaine, Valérie; Le Hanneur, Malo; Anract, Philippe

    2018-01-27

    Despite numerous reconstructive techniques and prosthetic devices, pelvic reconstructions following peri-acetabular malignant tumours resections are highly challenging. In the present study, we describe our experience with the Integra® (Lépine, Genay, France) ice-cream cone prosthesis in such indications. The objective was to assess the mid-term outcomes of this device. Twenty-four patients' chart with peri-acetabular malignant tumours, who underwent types II or II + III peri-acetabular resections according to Enneking and Dunham with subsequent reconstruction using the Integra® prosthesis between February 2009 and February 2015, were reviewed. Seventeen cases were primary surgeries and seven cases were revisions (i.e., failures of previous reconstructions for pelvic tumours). All living patients with the prosthesis implanted were functionally assessed, using the musculoskeletal tumour society (MSTS) and Postel-Merle d'Aubigné (PMA) scores. After a mean follow-up of 49 ± 26 months (range, 8 to 94 months), 21 patients were alive (88%), including 15 patients continuously disease-free (63%). MSTS and PMA scores averaged 72 ± 13% (range, 43 to 87%) and 14.6 ± 2.6 (range, 9 to 18), respectively. Fourteen patients (58%) presented at least one complication during follow-up, including four cases of deep infection (17%), four cases of dislocation (17%), and two mechanical failures (8%). At 5 years, the implant survival rate was 75%. In comparison to previous reconstructive techniques that we used in similar indications, functional and oncologic outcomes were improved with the Integra® implant. However, as commonly observed in pelvic bone tumour surgery, complication rates remain significant. Therapeutic, Level IV-Retrospective Cases Series.

  8. 21 CFR 872.3950 - Glenoid fossa prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Glenoid fossa prosthesis. 872.3950 Section 872.3950 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3950 Glenoid fossa prosthesis. (a) Identification...

  9. 21 CFR 878.3750 - External prosthesis adhesive.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false External prosthesis adhesive. 878.3750 Section 878.3750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3750 External prosthesis...

  10. 21 CFR 878.3750 - External prosthesis adhesive.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false External prosthesis adhesive. 878.3750 Section 878.3750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3750 External prosthesis...

  11. 21 CFR 878.3750 - External prosthesis adhesive.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false External prosthesis adhesive. 878.3750 Section 878.3750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3750 External prosthesis...

  12. 21 CFR 878.3750 - External prosthesis adhesive.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false External prosthesis adhesive. 878.3750 Section 878.3750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3750 External prosthesis...

  13. 21 CFR 878.3750 - External prosthesis adhesive.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false External prosthesis adhesive. 878.3750 Section 878.3750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3750 External prosthesis...

  14. Novel knee joint mechanism of transfemoral prosthesis for stair ascent.

    PubMed

    Inoue, Koh; Wada, Takahiro; Harada, Ryuchi; Tachiwana, Shinichi

    2013-06-01

    The stability of a transfemoral prosthesis when walking on flat ground has been established by recent advances in knee joint mechanisms and their control methods. It is, however, difficult for users of a transfemoral prosthesis to ascend stairs. This difficulty is mainly due to insufficient generation of extension moment around the knee joint of the prosthesis to lift the body to the next step on the staircase and prevent any unexpected flexion of the knee joint in the stance phase. Only a prosthesis with an actuator has facilitated stair ascent using a step-over-step gait (1 foot is placed per step). However, its use has issues associated with the durability, cost, maintenance, and usage environment. Therefore, the purpose of this research is to develop a novel knee joint mechanism for a prosthesis that generates an extension moment around the knee joint in the stance phase during stair ascent, without the use of any actuators. The proposed mechanism is based on the knowledge that the ground reaction force increases during the stance phase when the knee flexion occurs. Stair ascent experiments with the prosthesis showed that the proposed prosthesis can realize stair ascent without any undesirable knee flexion. In addition, the prosthesis is able to generate a positive knee joint moment power in the stance phase even without any power source.

  15. Tibial Tubercle Osteotomies: a Review of a Treatment for Recurrent Patellar Instability.

    PubMed

    Grimm, Nathan L; Lazarides, Alexander L; Amendola, Annunziato

    2018-06-01

    The goal of this review is to provide an overview of current surgical treatment options for tibial tubercle osteotomies as a treatment for recurrent patellofemoral instability. As such we sought to provide the reader with the most current answers to why treatment practices have changed and how this has affected the outcome of surgical treatment for patellar instability. As our understanding of patellofemoral biomechanics have grown, appropriate surgical and non-surgical treatment options have followed suit to address these findings. A clear understanding of the pathomechanics causing the patient's patellar instability is germane to choosing the most appropriate surgical intervention to address this instability. Likewise, understanding the goal of the intervention chosen-e.g., unloading, realignment-is paramount. These surgical techniques may be technically challenging and surgical specialists with experience in these techniques are recommended for optimal outcomes.

  16. Chronic bilateral dislocation of temporomandibular joint.

    PubMed

    Shakya, S; Ongole, R; Sumanth, K N; Denny, C E

    2010-01-01

    Dislocation of the condyle of the mandible is a common condition that may occur in an acute or chronic form. It is characterised by inability to close the mouth with or without pain. Dislocation has to be differentiated from subluxation which is a self reducible condition. Dislocation can occur in any direction with anterior dislocation being the commonest one. Various predisposing factors have been associated with dislocation like muscle fatigue and spasm, the defect in the bony surface like shallow articular eminence, and laxity of the capsular ligament. People with defect in collagen synthesis like Ehler Danlos syndrome, Marfan syndrome are said to be genetically predisposed to this condition. Various treatment modalities have been used ranging from conservative techniques to surgical methods. Acute dislocations can be reduced manually or with conservative approach and recurrent and chronic cases can be reduced by surgical intervention. Though the dislocation in our case was 4 months a simple manual reduction proved to be successful. We believe that manual reduction can be attempted as first line of treatment prior to surgical intervention.

  17. 21 CFR 888.3790 - Wrist joint metal constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint metal constrained cemented prosthesis... SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3790 Wrist joint metal constrained cemented prosthesis. (a) Identification. A wrist joint metal constrained cemented prosthesis is a...

  18. 21 CFR 888.3790 - Wrist joint metal constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Wrist joint metal constrained cemented prosthesis... SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3790 Wrist joint metal constrained cemented prosthesis. (a) Identification. A wrist joint metal constrained cemented prosthesis is a...

  19. [Palmar lunate dislocation].

    PubMed

    Isenberg, J; Prokop, A; Schellhammer, F; Helling, H J

    2002-12-01

    Palmar lunate dislocation as the end stage of a perilunate dislocation is a very uncommon injury. Having treated 19,534 hospitalized patients between 1 January 1986 and 1 October 2001 the diagnosis was recorded in four male trauma patients (33, 36, 37 and 62 years old). Among the operatively treated carpal dislocations and carpal fracture dislocations those of the lunate were seen in five per cent. The dislocation was caused in by an acute hyperextension injury resulting of falls from heights in three cases, and of a motorcycle accident in a further case. In two of these cases a complete palmar lunate dislocation was analysed that were produced by fall from seven meters heights of a young craftsman and by accident of a motorcyclist. First using a longitudinal palmar approach in both cases a revision of the hemorrhagic carpal canal was performed urgently, the largely denuded lunate was reduced and the repair of identified ligamentous structures was performed by means of sutures respectively suture anchors. Reduction was stabilized with Kirschner wires. Afterwards performed computed tomography identified the result of reduction and associated defects (subluxation distal radioulnar joint). In one patient a soft tissue infection prevented the dorsal ligamentous repair. In spite of a consequent after-treatment and a good functional result a scapho-lunate dissociation was proved. An avascular defect of the lunate could be excluded by magnetic resonance imaging. In case of a secondary performed dorsal repair a persisting carpal stabilization with a satisfactory functional result could achieved. At second hand an advanced carpal collapse was proved. If reduction cannot be achieved by closed manipulation or a loss of reduction is shown, open reduction is indicated first by a palmar approach. An additional dorsal ligamentous repair seems to be necessary. Transfixation by Kirschner wires and suture anchors stabilize the restored anatomic relationships. Wrist immobilization in

  20. Neovascularity in patellar tendinopathy and the response to eccentric training: a case report using Power Doppler ultrasound.

    PubMed

    McCreesh, Karen M; Riley, Sara J; Crotty, James M

    2013-12-01

    This report describes the case of an amateur soccer player with chronic patellar tendinopathy who underwent ultrasound imaging before and after engaging in an 8-week programme of eccentric exercise. On initial assessment, greyscale ultrasound imaging demonstrated tendon thickening and reduced echogenicity, while Power Doppler imaging demonstrated a large amount of neovascularity. After 8 weeks of an eccentric loading programme, the patient reported significantly improved symptoms and functional scores, while follow-up imaging demonstrated improvement in the echo appearance of the tendon and complete resolution of the neovascularity. The association between neovascularity and symptoms in tendinopathy research is conflicting, with a paucity of research in the area of patellar tendinopathy. While further research is needed to clarify the significance of greyscale and Power Doppler ultrasound changes in relation to symptoms in patellar tendinopathy, ultrasound imaging was shown to be a useful adjunct to diagnosis and outcome assessment in this case. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. Worker Dislocation. Case Studies of Causes and Cures.

    ERIC Educational Resources Information Center

    Cook, Robert F., Ed.

    Case studies were made of the following dislocated worker programs: Cummins Engine Company Dislocated Worker Project; GM-UAW Metropolitan Pontiac Retraining and Employment Program; Minnesota Iron Range Dislocated Worker Project; Missouri Dislocated Worker Program Job Search Assistance, Inc.; Hillsborough, North Carolina, Dislocated Worker Project;…

  2. Dislocation mechanisms in stressed crystals with surface effects

    NASA Astrophysics Data System (ADS)

    Wu, Chi-Chin; Crone, Joshua; Munday, Lynn; Discrete Dislocation Dynamics Team

    2014-03-01

    Understanding dislocation properties in stressed crystals is the key for important processes in materials science, including the strengthening of metals and the stress relaxation during the growth of hetero-epitaxial structures. Despite existing experimental approaches and theories, many dislocation mechanisms with surface effects still remain elusive in experiments. Even though discrete dislocation dynamics (DDD) simulations are commonly employed to study dislocations, few demonstrate sufficient computational capabilities for massive dislocations with the combined effects of surfaces and stresses. Utilizing the Army's newly developed FED3 code, a DDD computation code coupled with finite elements, this work presents several dislocation mechanisms near different types of surfaces in finite domains. Our simulation models include dislocations in a bended metallic cantilever beam, near voids in stressed metals, as well as threading and misfit dislocations in as-grown semiconductor epitaxial layers and their quantitative inter-correlations to stress relaxation and surface instability. Our studies provide not only detailed physics of individual dislocation mechanisms, but also important collective dislocation properties such as dislocation densities and strain-stress profiles and their interactions with surfaces.

  3. Hamstring tendon versus patellar tendon anterior cruciate ligament reconstruction using biodegradable interference fit fixation: a prospective matched-group analysis.

    PubMed

    Wagner, Michael; Kääb, Max J; Schallock, Jessica; Haas, Norbert P; Weiler, Andreas

    2005-09-01

    There are still controversies about graft selection for primary anterior cruciate ligament reconstruction, especially with respect to knee stability and functional outcome. Biodegradable interference screw fixation of hamstring tendon grafts provides clinical results similar to those achieved with identical fixation of bone-patellar tendon-bone grafts. Cohort study; Level of evidence, 2. In 1996 and 1997, primary isolated anterior cruciate ligament reconstruction using a bone-patellar tendon-bone autograft was performed in 72 patients. Since 1998, hamstring tendons were used as routine grafts. Matched patients with a hamstring tendon graft were selected from a database (n = 284). All patients were followed prospectively for a minimum of 2 years with KT-1000 arthrometer testing, International Knee Documentation Committee score, and Lysholm score. In the bone-patellar tendon-bone group, 9 patients were excluded because of bilateral rupture of the anterior cruciate ligament, 3 patients (4.2%) had a graft rupture, and 4 patients were lost to follow-up (follow-up rate, 92.1%), leaving 56 patients for a matched-group analysis. In the hamstring tendon database, the graft rupture rate was 5.6% (P = .698). The Lysholm score was 89.7 in the patellar tendon group and 94 in the hamstring tendon group (P = .003). The KT-1000 arthrometer side-to-side difference was 2.6 mm for the patellar tendon group and 2.1 mm for the hamstring tendon group (P = .041). There were significantly less positive pivot-shift test results in the hamstring tendon group (P = .005), and hamstring tendon patients showed lower thigh atrophy (P = .024) and patellofemoral crepitus (P = .003). Overall International Knee Documentation Committee scores were better (P = .001) in the hamstring tendon group (hamstring tendon: 34 x A, 21 x B, 0 x C, 0 x D; bone-patellar tendon-bone: 17 x A, 32 x B, 6 x C, 0 x D). In this comparison of anterior cruciate ligament reconstruction with bone-patellar tendon-bone and

  4. Intermittent, noncyclic dysfunction of a mechanical aortic prosthesis by pannus formation.

    PubMed

    Giroux, Sylvie K; Labinaz, Marino X; Grisoli, Dominique; Klug, Andrew P; Veinot, John P; Burwash, Ian G

    2010-01-01

    Mechanical aortic prosthesis dysfunction can result from thrombosis or pannus formation. Pannus formation usually restricts systolic excursion of the occluding disk, resulting in progressive stenosis of the aortic prosthesis. Intermittent dysfunction of a mechanical aortic prosthesis is usually ascribed to thrombus formation. We describe an unusual case of intermittent, noncyclic dysfunction of a mechanical aortic prosthesis due to pannus formation in the absence of systolic restriction of disk excursion that presented with intermittent massive aortic regurgitation, severe ischemia, and shock. Pannus formation should be considered as a potential cause of acute intermittent severe aortic regurgitation in a patient with a mechanical aortic prosthesis.

  5. Rehabilitation protocol for patellar tendinopathy applied among 16- to 19-year old volleyball players.

    PubMed

    Biernat, Ryszard; Trzaskoma, Zbigniew; Trzaskoma, Lukasz; Czaprowski, Dariusz

    2014-01-01

    The aim of the study was to investigate the efficacy of rehabilitation protocol applied during competitive period for the treatment of patellar tendinopathy. A total of 28 male volleyball players were divided into two groups. Fifteen from experimental group (E) and 13 from control group (C) fulfilled the same tests 3 times: before the training program started (first measurement), after 12 weeks (second measurement) and after 24 weeks (third measurement). The above-mentioned protocol included the following: USG imagining with color Doppler function, clinical testing, pain intensity evaluation with VISA-P questionnaire, leg muscle strength and power and jumping ability measurements. The key element of the rehabilitation program was eccentric squat on decline board with additional unstable surface. The essential factor of the protocol was a set of preventive functional exercises, with focus on eccentric exercises of hamstrings. Patellar tendinopathy was observed in 18% of the tested young volleyball players. Implementation of the presented rehabilitation protocol with eccentric squat on decline board applied during sports season lowered the pain level of the young volleyball players. Presented rehabilitation protocol applied without interrupting the competitive period among young volleyball players together with functional exercises could be an effective method for the treatment of patellar tendinopathy.

  6. The Evolution and Utility of the Small-Carrion Prosthesis, Its Impact, and Progression to the Modern-Day Malleable Penile Prosthesis.

    PubMed

    Martinez, Daniel R; Terlecki, Ryan; Brant, William O

    2015-11-01

    Erectile dysfunction has plagued humanity for millennia. For years, treatment had been in the hands of mental health professionals. It was not until the 1970s that urologists created a modality that was marketable, reproducible, and consistently successful at treating impotence, the Small-Carrion Penile Prosthesis. We present the evolution of the malleable/semi-rigid penile prosthesis, concentrating our efforts reviewing and critiquing the pivotal article published by Drs. Michael P. Small, Hernan M. Carrion, and Julian A. Gordon. We then discuss its continued advancement, current-day utilization, and the future of the malleable prosthesis. From the early 1900s, surgeons have been toying with the idea of creating a penile implant. These initial attempts utilized rib cartilage, and eventually synthetic materials, including acrylic, silicone, and polyethylene. In 1975, Drs. Carrion and Small presented their initial experience of 31 patients utilizing their silicone implant. In their manuscript titled, "The Small-Carrion Penile Prosthesis: New Implant for the Management of Impotence," they discuss their technique, perioperative management of complications, and results. The malleable penile prosthesis continued to evolve throughout the years to the current day Genesis and Spectra. Although the current market is dominated by the inflatable penile prosthesis, there are specific situations where the malleable is ideally utilized. The pivotal article by Drs. Carrion and Small helped pave the way for the "New Era" of penile prosthetics and still remains one of the most impactful contributions to the management of erectile dysfunction. © 2015 International Society for Sexual Medicine.

  7. 21 CFR 888.3760 - Wrist joint carpal scaphoid polymer prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint carpal scaphoid polymer prosthesis. 888.3760 Section 888.3760 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... scaphoid polymer prosthesis. (a) Identification. A wrist joint carpal scaphoid polymer prosthesis is a one...

  8. 21 CFR 888.3770 - Wrist joint carpal trapezium polymer prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint carpal trapezium polymer prosthesis. 888.3770 Section 888.3770 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... trapezium polymer prosthesis. (a) Identification. A wrist joint carpal trapezium polymer prosthesis is a one...

  9. 21 CFR 888.3750 - Wrist joint carpal lunate polymer prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint carpal lunate polymer prosthesis. 888.3750 Section 888.3750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... lunate polymer prosthesis. (a) Identification. A wrist joint carpal lunate prosthesis is a one-piece...

  10. 21 CFR 888.3750 - Wrist joint carpal lunate polymer prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Wrist joint carpal lunate polymer prosthesis. 888.3750 Section 888.3750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... lunate polymer prosthesis. (a) Identification. A wrist joint carpal lunate prosthesis is a one-piece...

  11. 21 CFR 888.3770 - Wrist joint carpal trapezium polymer prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Wrist joint carpal trapezium polymer prosthesis. 888.3770 Section 888.3770 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... trapezium polymer prosthesis. (a) Identification. A wrist joint carpal trapezium polymer prosthesis is a one...

  12. 21 CFR 888.3760 - Wrist joint carpal scaphoid polymer prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Wrist joint carpal scaphoid polymer prosthesis. 888.3760 Section 888.3760 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... scaphoid polymer prosthesis. (a) Identification. A wrist joint carpal scaphoid polymer prosthesis is a one...

  13. 21 CFR 888.3750 - Wrist joint carpal lunate polymer prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Wrist joint carpal lunate polymer prosthesis. 888.3750 Section 888.3750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... lunate polymer prosthesis. (a) Identification. A wrist joint carpal lunate prosthesis is a one-piece...

  14. 21 CFR 888.3770 - Wrist joint carpal trapezium polymer prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Wrist joint carpal trapezium polymer prosthesis. 888.3770 Section 888.3770 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... trapezium polymer prosthesis. (a) Identification. A wrist joint carpal trapezium polymer prosthesis is a one...

  15. 21 CFR 888.3760 - Wrist joint carpal scaphoid polymer prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Wrist joint carpal scaphoid polymer prosthesis. 888.3760 Section 888.3760 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... scaphoid polymer prosthesis. (a) Identification. A wrist joint carpal scaphoid polymer prosthesis is a one...

  16. 21 CFR 888.3770 - Wrist joint carpal trapezium polymer prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Wrist joint carpal trapezium polymer prosthesis. 888.3770 Section 888.3770 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... trapezium polymer prosthesis. (a) Identification. A wrist joint carpal trapezium polymer prosthesis is a one...

  17. 21 CFR 888.3750 - Wrist joint carpal lunate polymer prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Wrist joint carpal lunate polymer prosthesis. 888.3750 Section 888.3750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... lunate polymer prosthesis. (a) Identification. A wrist joint carpal lunate prosthesis is a one-piece...

  18. 21 CFR 888.3760 - Wrist joint carpal scaphoid polymer prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Wrist joint carpal scaphoid polymer prosthesis. 888.3760 Section 888.3760 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... scaphoid polymer prosthesis. (a) Identification. A wrist joint carpal scaphoid polymer prosthesis is a one...

  19. 21 CFR 888.3750 - Wrist joint carpal lunate polymer prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Wrist joint carpal lunate polymer prosthesis. 888.3750 Section 888.3750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... lunate polymer prosthesis. (a) Identification. A wrist joint carpal lunate prosthesis is a one-piece...

  20. 21 CFR 888.3760 - Wrist joint carpal scaphoid polymer prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Wrist joint carpal scaphoid polymer prosthesis. 888.3760 Section 888.3760 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... scaphoid polymer prosthesis. (a) Identification. A wrist joint carpal scaphoid polymer prosthesis is a one...

  1. 21 CFR 888.3770 - Wrist joint carpal trapezium polymer prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Wrist joint carpal trapezium polymer prosthesis. 888.3770 Section 888.3770 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... trapezium polymer prosthesis. (a) Identification. A wrist joint carpal trapezium polymer prosthesis is a one...

  2. The effect of in situ freezing on rabbit patellar tendon. A histologic, biochemical, and biomechanical analysis

    NASA Technical Reports Server (NTRS)

    Graf, B. K.; Fujisaki, K.; Vanderby, R. Jr; Vailas, A. C.

    1992-01-01

    Cell necrosis has been well documented as one of the many changes that occur in autogenous tendon when it is used to reconstruct the anterior cruciate ligament. The purpose of this experiment was to isolate cell necrosis as a variable and study its effect on the patellar tendon. To accomplish this, both knees of 25 New Zealand White rabbits were operated on. In one knee, a 5-mm wide band of patellar tendon was subjected to two rapid freeze-thaw cycles, while the other knee underwent sham surgery. Histologic evaluation showed a zone of necrosis at 2 and 4 weeks with cellular repopulation complete at 8 weeks. patellar tendon cross-sectional area was 0.118 cm2 at 8 weeks for the frozen specimens compared to 0.102 cm2 for the sham-operated controls. This difference was significant at the P = 0.025 level. Mechanical testing at 4 and 8 weeks revealed no significant changes in tendon length, maximum load, or stiffness. The collagen content was also unchanged at both 4 and 8 weeks.

  3. Dislocation dynamics in hexagonal close-packed crystals

    DOE PAGES

    Aubry, S.; Rhee, M.; Hommes, G.; ...

    2016-04-14

    Extensions of the dislocation dynamics methodology necessary to enable accurate simulations of crystal plasticity in hexagonal close-packed (HCP) metals are presented. They concern the introduction of dislocation motion in HCP crystals through linear and non-linear mobility laws, as well as the treatment of composite dislocation physics. Formation, stability and dissociation of and other dislocations with large Burgers vectors defined as composite dislocations are examined and a new topological operation is proposed to enable their dissociation. Furthermore, the results of our simulations suggest that composite dislocations are omnipresent and may play important roles both in specific dislocation mechanisms and in bulkmore » crystal plasticity in HCP materials. While fully microscopic, our bulk DD simulations provide wealth of data that can be used to develop and parameterize constitutive models of crystal plasticity at the mesoscale.« less

  4. Comparison of dislocation density tensor fields derived from discrete dislocation dynamics and crystal plasticity simulations of torsion

    DOE PAGES

    Jones, Reese E.; Zimmerman, Jonathan A.; Po, Giacomo; ...

    2016-02-01

    Accurate simulation of the plastic deformation of ductile metals is important to the design of structures and components to performance and failure criteria. Many techniques exist that address the length scales relevant to deformation processes, including dislocation dynamics (DD), which models the interaction and evolution of discrete dislocation line segments, and crystal plasticity (CP), which incorporates the crystalline nature and restricted motion of dislocations into a higher scale continuous field framework. While these two methods are conceptually related, there have been only nominal efforts focused at the global material response that use DD-generated information to enhance the fidelity of CPmore » models. To ascertain to what degree the predictions of CP are consistent with those of DD, we compare their global and microstructural response in a number of deformation modes. After using nominally homogeneous compression and shear deformation dislocation dynamics simulations to calibrate crystal plasticity ow rule parameters, we compare not only the system-level stress-strain response of prismatic wires in torsion but also the resulting geometrically necessary dislocation density fields. To establish a connection between explicit description of dislocations and the continuum assumed with crystal plasticity simulations we ascertain the minimum length-scale at which meaningful dislocation density fields appear. Furthermore, our results show that, for the case of torsion, that the two material models can produce comparable spatial dislocation density distributions.« less

  5. Treatment of Patellar Tendinopathy Refractory to Surgical Management Using Percutaneous Ultrasonic Tenotomy and Platelet-Rich Plasma Injection: A Case Presentation.

    PubMed

    Nanos, Katherine N; Malanga, Gerard A

    2015-12-01

    Chronic proximal patellar tendinopathy is a common condition in sports medicine that may be refractory to nonoperative treatments, including activity modification, medications, and comprehensive rehabilitation. Percutaneous ultrasonic tenotomy is a recently developed technique designed to cut and debride tendinopathic tissue, thus promoting pain relief and functional recovery. We present a case of a collegiate athlete with chronic proximal patellar tendinopathy who was effectively treated with percutaneous ultrasonic tenotomy after not responding to extensive nonoperative treatment, surgical debridement, and platelet-rich plasma injections. Percutaneous ultrasonic tenotomy can be considered as a treatment option in patients presenting with refractory proximal patellar tendinopathy, including those who do not respond to previous operative intervention. Copyright © 2015 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  6. Impact of patellar height on unicompartment knee arthroplasty: does patella baja lead to an inferior outcome?

    PubMed

    Neogi, Devdatta Suhas; Bae, Ji Hoon; Seok, Chang Woo; Lim, Hong Chul

    2014-03-01

    Though a number of series with long-term results have been published, there is still a paucity of literature on the role of patellar height after unicompartment knee arthroplasty (UKA). The present study was conducted with a hypothesis that patella baja may lead to a poor outcome at follow-up. A retrospective review of 134 knees was performed and patellar height calculated before and after UKA by Blackburne-Peel index (BPI) and the Insall-Salvati ratio (ISR) on true lateral radiographs of the patients in 30° of flexion taken pre-operatively and at 1 year, 2 years and final follow-up (minimum 5 years). Statistical analysis was performed to evaluate the outcomes. There was a decrease in ISR in 14.18 % and in BPI in 19.4 % at final follow-up. There was a significant decrease in BPI values while the decrease was not significant for ISR. After eliminating the pre-operative patella baja, 7.3 % developed post-operative patella baja, according to ISR, while 11.5 % developed patella baja as per BPI. At final follow-up there was a statistically significant decrease in stair climbing scores in patients with patella baja when compared to patients with normal ISR. Patients with a decrease in patellar height as per ISR have a decrease in stair climbing score at mid-term follow-up while the overall KSS, and pain scores are not affected by a change in patellar height and neither is there a significant progress in patellofemoral osteoarthritis among patients with patella baja compared to normal patella.

  7. Penile Prosthesis Implantation in Patients with a History of Total Phallic Construction.

    PubMed

    Zuckerman, Jack M; Smentkowski, Katherine; Gilbert, David; Storme, Oscar; Jordan, Gerald; Virasoro, Ramon; Tonkin, Jeremy; McCammon, Kurt

    2015-12-01

    Outcomes following penile prosthesis implantation in patients with a history of total phallic construction are not well described. The aim of this study was to evaluate outcomes following neophallus penile prosthesis placement. Retrospective review penile prosthesis placement in patients with prior total phallic construction. GORE-TEX® (Gore Medical, Flagstaff, AZ) sleeve neotunica construction was utilized in all patients. Success defined as patient sexual activity with a functioning prosthesis. Thirty-one patients underwent neophallic prosthesis implantation at a mean 35.6 years of age. Prosthesis placement occurred at an average 56.3 months following phallic construction and follow-up was a mean of 59.7 months. Malleable prostheses were placed in 21 patients and inflatable in 10; implants were bilateral in 94%. Six percent experienced operative complications including a bladder injury (1) and phallic flap arterial injury (1). Postoperative complications occurred in 23% at a median 5.5 months following placement. Five prostheses were explanted secondary to infection or erosion and two additional required revisions. Of the explanted prosthesis two were later replaced without further complication. Eighty-one percent of patients were sexually active following prosthesis placement. Penile prosthesis placement is possible in patients with prior penile reconstruction/phallic construction. Although complications rates appear to be elevated in this population compared with historic controls of normal anatomic men, the majority of patients in this series were sexually active following prosthesis placement. This demonstrates the utility of prosthesis implantation in these difficult patients. © 2015 International Society for Sexual Medicine.

  8. Fabrication of a Cranial Prosthesis Combined with an Ocular Prosthesis Using Rapid Prototyping: A Case Report.

    PubMed

    Shankaran, Gayatri; Deogade, Suryakant Chhagan; Dhirawani, Rajesh

    2016-01-01

    Rapid prototyping (RP) is a technique of manufacturing parts by the additive layer manufacturing technology; where, a three-dimensional (3D) model created in a computer aided design (CAD) system is sectioned into 2D profiles, which are further constructed by RP layer by layer. Its use is not limited to industrial or engineering fields and has extended to the medical field for the manufacturing of custom implants and prostheses, the study of anatomy and surgical planning. Nowadays, dentists are more frequently encountered with the individuals affected with craniofacial defects due to trauma. In such cases, the craniomaxillofacial rehabilitation is a real challenge to bring the patients back to society and promote their well-being. The conventional impression technique for facial prosthesis fabrication has the disadvantage of deforming the soft tissue and causing discomfort for the patient. Herein, we describe the fabrication of a cranial prosthesis combined with an ocular prosthesis with RP and stereolithography.

  9. Fabrication of a Cranial Prosthesis Combined with an Ocular Prosthesis Using Rapid Prototyping: A Case Report

    PubMed Central

    Shankaran, Gayatri; Dhirawani, Rajesh

    2016-01-01

    Rapid prototyping (RP) is a technique of manufacturing parts by the additive layer manufacturing technology; where, a three-dimensional (3D) model created in a computer aided design (CAD) system is sectioned into 2D profiles, which are further constructed by RP layer by layer. Its use is not limited to industrial or engineering fields and has extended to the medical field for the manufacturing of custom implants and prostheses, the study of anatomy and surgical planning. Nowadays, dentists are more frequently encountered with the individuals affected with craniofacial defects due to trauma. In such cases, the craniomaxillofacial rehabilitation is a real challenge to bring the patients back to society and promote their well-being. The conventional impression technique for facial prosthesis fabrication has the disadvantage of deforming the soft tissue and causing discomfort for the patient. Herein, we describe the fabrication of a cranial prosthesis combined with an ocular prosthesis with RP and stereolithography. PMID:27536331

  10. Ultrasonic influence on evolution of disordered dislocation structures

    NASA Astrophysics Data System (ADS)

    Bachurin, D. V.; Murzaev, R. T.; Nazarov, A. A.

    2017-12-01

    Evolution of disordered dislocation structures under ultrasonic influence is studied in a model two-dimensional grain within the discrete-dislocation approach. Non-equilibrium grain boundary state is mimicked by a mesodefect located at the corners of the grain, stress field of which is described by that of a wedge junction disclination quadrupole. Significant rearrangement related to gliding of lattice dislocations towards the grain boundaries is found, which results in a noticeable reduction of internal stress fields and cancel of disclination quadrupole. The process of dislocation structure evolution passes through two stages: rapid and slow. The main dislocation rearrangement occurs during the first stage. Reduction of internal stress fields is associated with the number of dislocations entered into the grain boundaries. The change of misorientation angle due to lattice dislocations absorbed by the grain boundaries is evaluated. Amplitude of ultrasonic treatment significantly influences the relaxation of dislocation structure. Preliminary elastic relaxation of dislocation structure does not affect substantially the results of the following ultrasonic treatment. Substantial grain size dependence of relaxation of disordered dislocation systems is found. Simulation results are consistent with experimental data.

  11. Thermodynamic dislocation theory: Bauschinger effect

    NASA Astrophysics Data System (ADS)

    Le, K. C.; Tran, T. M.

    2018-04-01

    The thermodynamic dislocation theory developed for nonuniform plastic deformations is used here to simulate the stress-strain curves for crystals subjected to antiplane shear-controlled load reversal. We show that the presence of the positive back stress during the load reversal reduces the magnitude of shear stress required to pull excess dislocations back to the center of the specimen. There, the excess dislocations of opposite signs meet and annihilate each other leading to the Bauschinger effect.

  12. Are unilateral and bilateral patellar tendinopathy distinguished by differences in anthropometry, body composition, or muscle strength in elite female basketball players?

    PubMed Central

    Gaida, J; Cook, J; Bass, S; Austen, S; Kiss, Z

    2004-01-01

    Background: Overuse injury to the patellar tendon (patellar tendinopathy) is a major reason for interrupted training and competition for elite athletes. In both sexes, the prevalence of unilateral and bilateral tendinopathy has been shown to differ. It has been proposed that bilateral pathology may have a different aetiology from unilateral pathology. Investigation of risk factors that may be unique to unilateral and bilateral patellar tendinopathy in female athletes may reveal insights into the aetiology of this condition. Objectives: To examine whether anthropometry, body composition, or muscle strength distinguished elite female basketball players with unilateral or bilateral patellar tendinopathy. Methods: Body composition, anthropometry, and muscle strength were compared in elite female basketball players with unilateral (n = 8), bilateral (n = 7), or no (n = 24) patellar tendinopathy. Body composition was analysed using a dual energy x ray absorptiometer. Anthropometric measures were assessed using standard techniques. Knee extensor strength was measured at 180°/s using an isokinetic dynamometer. z scores were calculated for the unilateral and bilateral groups (using the no tendinopathy group as controls). z scores were tested against zero. Results: The tibia length to stature ratio was approximately 1.3 (1.3) SDs above zero in both the affected and non-affected legs in the unilateral group (p<0.05). The waist to hip ratio was 0.66 (0.78) SD above zero in the unilateral group (p<0.05). In the unilateral group, leg lean to total lean ratio was 0.42 (0.55) SD above zero (p<0.07), the trunk lean to total lean ratio was 0.63 (0.68) SD below zero (p<0.05), and leg fat relative to total fat was 0.47 (0.65) SD below zero (p<0.09). In the unilateral group, the leg with pathology was 0.78 (1.03) SD weaker during eccentric contractions (p<0.07). Conclusions: Unilateral patellar tendinopathy has identifiable risk factors whereas bilateral patellar tendinopathy may not

  13. Metabolics of stair ascent with a powered transfemoral prosthesis.

    PubMed

    Ledoux, E D; Lawson, B E; Shultz, A H; Bartlett, H L; Goldfarb, M

    2015-01-01

    This paper evaluates the effectiveness of a powered knee and ankle prosthesis for stair ascent through a metabolic assessment comparing energy expenditure of a single transfemoral amputee subject while ascending stairs with the powered prosthesis relative to his passive daily use device, as well as comparing the kinematics and kinetics obtained with the passive prosthesis to healthy biomechanics. The subject wore a portable system that measured pulmonary gaseous exchange rates of oxygen and carbon dioxide while he ascended stairs with each of the prostheses in alternating tests. The results indicated that the amputee's energy expenditure decreased by 32 percent while climbing with the powered prosthesis as compared to his passive one, and the kinematics and kinetics achieved were representative of healthy biomechanics.

  14. The chopstick-noodle twist: an easy technique of percutaneous patellar fixation in minimally displaced patellar fractures.

    PubMed

    Muzaffar, Nasir; Ahmad, Nawaz; Ahmad, Aejaz; Ahmad, Nissar

    2012-01-01

    We report six cases of minimally displaced two-part patellar fractures with skin injury over the patella that were treated with percutaneous K wire fixation and compression applied using stainless steel (SS) wire. This technique makes it possible to perform early operative treatment in cases where unhealthy skin is not amenable to conventional tension band wiring. The technique employs two K wires inserted through the two fracture fragments under local or regional anaesthesia. They are then compressed using simple SS wire knots at the two ends - making it look like noodles at the end of two chopsticks. The fixation is subsequently augmented with a cylindrical plaster-of-Paris cast. The technique is simple, cheap and does not cause soft tissue injury.

  15. Successful conservative management of symptomatic bilateral dorsal patellar defects presenting with cartilage involvement and bone marrow edema: MRI findings.

    PubMed

    Kwee, Thomas C; Sonneveld, Heleen; Nix, Maarten

    2016-05-01

    The dorsal patellar defect is a relatively rare entity that involves the superolateral quadrant of the patella. It is usually considered to represent a delayed ossification process, although its exact origin remains unclear. Because of its usually innocuous nature and clinical course, invasive interventions are generally deemed unnecessary, although curretage has been successfully performed on symptomatic cases. This case report presents a rather unusual case of symptomatic bilateral dorsal patellar defects with cartilage involvement and widespread surrounding bone marrow edema as demonstrated by magnetic resonance imaging (MRI). Both cartilage involvement and bone marrow edema should be considered part of the spectrum of associated MRI findings that can be encountered in this entity. Furthermore, the presented case shows that symptomatic dorsal patellar defects can be treated conservatively with success and that (decrease of) pain symptoms are likely related to (decrease of) bone marrow edema.

  16. Association between dental prosthesis need, nutritional status and quality of life of elderly subjects.

    PubMed

    Pillai, Rajath Sasidharan; Mathur, Vijay Prakash; Jain, Veena; Shah, Naseem; Kalra, Sandeep; Kumar, Pravesh; Dey, A B

    2015-12-01

    To determine the effect of prosthesis need on nutritional status and oral health-related quality of life (OHrQoL) in elderly and to check the disparity between prosthesis need and prosthesis want in the Indian elderly. A total of 946 geriatric participants reporting to a geriatric medicine clinic were recruited in the study. Mini-nutritional assessment (MNA), geriatric oral health assessment (GOHAI) indices, prosthesis need according to WHO criteria, and prosthesis want was recorded along with age, gender, socioeconomic status and posterior occluding pair. Significant associations exist between prosthesis need and age (p = 0.005), MNA (p = 0.006) and GOHAI (p = 0.000). Prosthesis demand too was influenced by age (p = 0.004), posterior occluding pairs (p = 0.000), MNA (p = 0.012) and GOHAI (p = 0.000). GOHAI was negatively correlated with upper (r = -0.445) and lower prosthesis need (r = -0.460). Participants with some prosthesis need had significantly lower MNA and GOHAI scores as compared to those with no prosthesis need. Though prosthesis need was high (79.7 %), demand was low (39.3 %). Prosthesis need affects nutritional status and OHrQoL in elderly, and a wide gap exists between need and want of prosthesis.

  17. Management of displaced comminuted patellar fracture with titanium cable cerclage.

    PubMed

    Yang, Li; Yueping, Ouyang; Wen, Yuan

    2010-08-01

    Management of a displaced comminuted patellar fracture is challenging. Tension band wiring and lag screw fixation are not suitable for such a fracture pattern. Stainless steel wiring with various configurations has been the mainstay of treatment. However, issues of loss of fixation and breakage of wire have not been resolved yet. Partial or total patellectomy is the last resort with a detrimental effect on quadriceps power. Braided titanium cable is stronger in tensile strength and better in fatigue resistance than the stainless steel monofilament wire, and the tension of fixation could be controlled by a graded instrument in its application. We used titanium cable to treat 21 consecutive patients with displaced comminuted patellar fracture. Patients were followed up for a mean period of 24 months (12 to 32 months). The mean score at the final follow-up was 27 points (25 to 30) using the Böstman method. There was no complication except breakage of one cable at the sixth week after the operation and the fracture had united despite the breakage. This technique is simple and effective for these difficult fractures and avoided prolonged immobilisation of the knee. Copyright 2010 Elsevier B.V. All rights reserved.

  18. Description of patellar movement by 3D parameters obtained from dynamic CT acquisition

    NASA Astrophysics Data System (ADS)

    de Sá Rebelo, Marina; Moreno, Ramon Alfredo; Gobbi, Riccardo Gomes; Camanho, Gilberto Luis; de Ávila, Luiz Francisco Rodrigues; Demange, Marco Kawamura; Pecora, Jose Ricardo; Gutierrez, Marco Antonio

    2014-03-01

    The patellofemoral joint is critical in the biomechanics of the knee. The patellofemoral instability is one condition that generates pain, functional impairment and often requires surgery as part of orthopedic treatment. The analysis of the patellofemoral dynamics has been performed by several medical image modalities. The clinical parameters assessed are mainly based on 2D measurements, such as the patellar tilt angle and the lateral shift among others. Besides, the acquisition protocols are mostly performed with the leg laid static at fixed angles. The use of helical multi slice CT scanner can allow the capture and display of the joint's movement performed actively by the patient. However, the orthopedic applications of this scanner have not yet been standardized or widespread. In this work we present a method to evaluate the biomechanics of the patellofemoral joint during active contraction using multi slice CT images. This approach can greatly improve the analysis of patellar instability by displaying the physiology during muscle contraction. The movement was evaluated by computing its 3D displacements and rotations from different knee angles. The first processing step registered the images in both angles based on the femuŕs position. The transformation matrix of the patella from the images was then calculated, which provided the rotations and translations performed by the patella from its position in the first image to its position in the second image. Analysis of these parameters for all frames provided real 3D information about the patellar displacement.

  19. Acute traumatic rupture of the patellar tendon in pediatric population: Case series and review of the literature.

    PubMed

    Ali Yousef, Mohamed Abdelhamid; Rosenfeld, Scott

    2017-11-01

    Intact knee extensor mechanism is required for the normal function of the lower extremity. Patellar tendon rupture is a relatively rare injury with peak age incidence around 40 years and usually occurs midsubstance. The occurrence of pure patellar tendon rupture without bony avulsion is an extremely rare injury in the pediatric population with few cases reported in the literature with limited information regarding frequency, complications, and outcomes in children. However, due to increased participation in sports and high-energy recreational activities during childhood, the frequency of such injuries has progressively increased. To evaluate the frequency of pediatric patellar tendon rupture injuries and describe the radiological findings, treatment modalities, and outcome of such injuries. Demographic and clinical data on a series of patients who sustained patellar tendon rupture were reviewed. These data included age at time of injury, sex, laterality, mechanism of injury, associated injuries, complications, presence or absence of Osgood-Schlatter disease, diagnostic imaging such as plain radiographs and magnetic resonance images (MRI), surgical technique, method of fixation, period of postoperative immobilization, total duration of physiotherapy, time to return to sports activities and follow-up duration. Insall-Salvati ratio was calculated on the preoperative lateral x-ray. The functional outcome was evaluated with regard to final knee active range of motion (AROM), manual quadriceps muscle testing, and presence or the absence of terminal extension lag. Clinical outcome rating using knee society score (KSS) was performed and functional outcome was further classified according to the calculated score. Five male patients with patellar tendon rupture (7%) were identified among 71 pediatric patients who sustained acute traumatic injury of the knee extensor mechanism. The mean age at the time of injury was 13.6 years (range: 12-15 years). The injury occurred in

  20. Penile prosthesis implant: scientific advances and technological innovations over the last four decades.

    PubMed

    Chung, Eric

    2017-02-01

    Despite introduction of oral phosphodiesterase type 5 inhibitors and intracavernosal vasoactive agents, penile prosthesis implant remains a relevant and desired option with sales of penile prostheses continue to stay high, as many men became refractory to medical therapy and/or seeking a more effective and permanent therapy. There are two types of penile prosthesis implants: inflatable and non-inflatable types, and the inflatable penile implants can be subdivided into single-, two- and three-piece devices. Non-inflatable penile prosthesis (non-IPP) may be referred to as semi-rigid rod or malleable prosthesis. IPP is considered a superior option to malleable prosthesis as it produces penile rigidity and flaccidity that closely replicates a normal penile erectile function. Since the introduction of IPP by Scott in 1973, surgical landscape for penile prosthesis implantation has changed dramatically. Advances in prosthesis design, device technologies and surgical techniques have made penile prosthesis implant a more natural, durable and reliable device. The following article reviews the scientific advances and technological innovation in modern penile prosthesis implants over the last four decades.

  1. Penile prosthesis implant: scientific advances and technological innovations over the last four decades

    PubMed Central

    2017-01-01

    Despite introduction of oral phosphodiesterase type 5 inhibitors and intracavernosal vasoactive agents, penile prosthesis implant remains a relevant and desired option with sales of penile prostheses continue to stay high, as many men became refractory to medical therapy and/or seeking a more effective and permanent therapy. There are two types of penile prosthesis implants: inflatable and non-inflatable types, and the inflatable penile implants can be subdivided into single-, two- and three-piece devices. Non-inflatable penile prosthesis (non-IPP) may be referred to as semi-rigid rod or malleable prosthesis. IPP is considered a superior option to malleable prosthesis as it produces penile rigidity and flaccidity that closely replicates a normal penile erectile function. Since the introduction of IPP by Scott in 1973, surgical landscape for penile prosthesis implantation has changed dramatically. Advances in prosthesis design, device technologies and surgical techniques have made penile prosthesis implant a more natural, durable and reliable device. The following article reviews the scientific advances and technological innovation in modern penile prosthesis implants over the last four decades. PMID:28217449

  2. Allograft-prosthesis composites after bone tumor resection at the proximal tibia.

    PubMed

    Biau, David Jean; Dumaine, Valérie; Babinet, Antoine; Tomeno, Bernard; Anract, Philippe

    2007-03-01

    The survival of irradiated allograft-prosthesis composites at the proximal tibia is mostly unknown. However, allograft-prosthesis composites have proved beneficial at other reconstruction sites. We presumed allograft-prosthesis composites at the proximal tibia would improve survival and facilitate reattachment of the extensor mechanism compared with that of conventional (megaprostheses) reconstructions. We retrospectively reviewed 26 patients who underwent resection of proximal tibia tumors followed by reconstruction with allo-graft-prosthesis composites. Patients received Guepar massive custom-made fully constrained prostheses. Allografts were sterilized with gamma radiation, and the stems were cemented into the allograft and host bone. The minimum followup was 6 months (median, 128 months; range, 6-195 months). Fourteen patients had one or more components removed. The median allograft-prosthesis composite survival was 102 months (95% confidence interval, 64.2-infinity). Of the 26 allografts, seven fractured, six showed signs of partial resorption, and six had infections develop. Seven allografts showed signs of fusion with the host bone. Six extensor mechanism reconstructions failed. Allograft-prosthesis composites sterilized by gamma radiation yielded poor results for proximal tibial reconstruction as complications and failures were common. We do not recommend irradiated allograft-prosthesis composites for proximal tibia reconstruction.

  3. Automated estimation of hip prosthesis migration: a feasibility study

    NASA Astrophysics Data System (ADS)

    Vandemeulebroucke, Jef; Deklerck, Rudi; Temmermans, Frederik; Van Gompel, Gert; Buls, Nico; Scheerlinck, Thierry; de Mey, Johan

    2013-09-01

    A common complication associated with hip arthoplasty is prosthesis migration, and for most cemented components a migration greater than 0.85 mm within the first six months after surgery, are an indicator for prosthesis failure. Currently, prosthesis migration is evaluated using X-ray images, which can only reliably estimate migrations larger than 5 mm. We propose an automated method for estimating prosthesis migration more accurately, using CT images and image registration techniques. We report on the results obtained using an experimental set-up, in which a metal prosthesis can be translated and rotated with respect to a cadaver femur, over distances and angles applied using a combination of positioning stages. Images are first preprocessed to reduce artefacts. Bone and prosthesis are extracted using consecutive thresholding and morphological operations. Two registrations are performed, one aligning the bones and the other aligning the prostheses. The migration is estimated as the difference between the found transformations. We use a robust, multi-resolution, stochastic optimization approach, and compare the mean squared intensity differences (MS) to mutual information (MI). 30 high-resolution helical CT scans were acquired for prosthesis translations ranging from 0.05 mm to 4 mm, and rotations ranging from 0.3° to 3° . For the translations, the mean 3D registration error was found to be 0.22 mm for MS, and 0.15 mm for MI. For the rotations, the standard deviation of the estimation error was 0.18° for MS, and 0.08° for MI. The results show that the proposed approach is feasible and that clinically acceptable accuracies can be obtained. Clinical validation studies on patient images will now be undertaken.

  4. 21 CFR 888.6 - Degree of constraint.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... replacement and prevents dislocation of the prosthesis in more than one anatomic plane and consists of either... translation and rotation of the prosthesis in one or more planes via the geometry of its articulating surfaces... total joint replacement and restricts minimally prosthesis movement in one or more planes. Its...

  5. Patellar tendon rupture repair using Dall-Miles cable.

    PubMed

    Shelbourne, K D; Darmelio, M P; Klootwyk, T E

    2001-01-01

    Ten patients underwent patellar tendon repair with end-to-end suture technique and medial and lateral retinacular repair, as well as reinforcement with a Dall-Miles cable through the patella and tibial tubercle. The cable was tensioned at 60 degrees of flexion to allow immediate range of motion to at least 100 degrees of flexion and to protect the repair from undue tension while healing. Accurate tendon length was obtained from a lateral radiograph of the noninvolved knee in 60 degrees of flexion. Patients were allowed to bear full weight as tolerated postoperatively. A knee immobilizer was worn for approximately 2 weeks when adequate muscular control of the leg was attained. The cable was removed 6-8 weeks postoperatively, at which time range of motion equal to the opposite extremity was sought. Full extension was obtained by 1 week postoperatively. Average postoperative knee flexion was 88 degrees at 2 weeks, 112 degrees at 1 month, 133 at 3 months, and 138 degrees at 6 months compared to flexion of 141 degrees in the noninvolved knee. Mean quadriceps muscle strength 1 year postoperatively was 72%+/-11% of the noninvolved leg. No patient had patella infera or rerupture after surgery. Repair of a patellar tendon rupture with end-to-end techniques reinforced with a Dall-Miles cable allows immediate rehabilitation without the need for prolonged immobilization. This technique allows restoration of full range of motion early postoperatively and enables patients to regain adequate quadriceps strength.

  6. Linking of total elbow prosthesis during surgery; a biomechanical analysis.

    PubMed

    De Vos, Maarten J; Wagener, Marc L; Hendriks, Jan C M; Eygendaal, Denise; Verdonschot, Nico

    2013-09-01

    Presently, 2 types of elbow prostheses are used: unlinked and linked. The Latitude total elbow prosthesis allows the surgeon to decide during the implantation whether the prosthesis is placed unlinked or linked, and whether the native radial head is retained, resected, or replaced. The purpose of this study is to assess and to compare the varus and valgus laxity of the unlinked and linked version of the latitude total elbow prosthesis with: (1) the native radial head preserved, (2) the native radial head excised, and (3) the native radial head replaced by a radial head component. Biomechanical testing was performed on 14 fresh-frozen upper limb specimens. Linking the prosthesis predominantly influences the valgus laxity of the elbow. Linking the Latitude total elbow prosthesis results in increased valgus stability. In the linked version of the total elbow prosthesis, the radial head only plays a small part in both valgus and varus stability. An unlinked situation is not advised in absence of a native radial head or in case of inability to replace the radial head. Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  7. Effects of static stretching of knee musculature on patellar alignment and knee functional disability in male patients diagnosed with knee extension syndrome: A single-group, pretest-posttest trial.

    PubMed

    Pourahmadi, Mohammad Reza; Ebrahimi Takamjani, Ismail; Hesampour, Kazem; Shah-Hosseini, Gholam Reza; Jamshidi, Ali Ashraf; Shamsi, Mohammad Bagher

    2016-04-01

    Knee extension (Kext) syndrome is based on movement system impairments and is described as knee pain associated with quadriceps stiffness. To investigate the effects of 3 times per week for 4 weeks static stretching of knee musculature on patellar alignment and knee functional disability in male Kext syndrome patients. A single-group, pretest-posttest clinical trial. Hazrat-e-Rasoul Akram Hospital. Forty-six male Kext syndrome patients aged 18-35 years. Knee functional disability was assessed by the Kujala questionnaire. Patellar tilt was assessed using the skyline view X-ray. In addition, patella alta was assessed by X-ray using the Insall-Salvati ratio. After intervention, changes in knee flexion-extension range of motion (ROM) and hip adduction were assessed by goniometer and inclinometer. Changes in patellar tilt and patella alta were evaluated. Correlations between muscles length, patellar tilt and knee functional disability were also evaluated. The mean of patellar tilt in male Kext syndrome patients was 15.19°. Only the correlation between rectus femoris shortness and patellar tilt (P = 0.002) and the correlation between rectus femoris shortness and knee functional disability (P = 0.037) were significant. Patella alta was not severe in male Kext syndrome patients (1.28 ± 0.10). Knee flexion-extension ROM and femoral adduction increased significantly after a 12-session stretching programme (P < 0.0001). The results demonstrated that rectus femoris shortness had higher correlation with patellar tilt and knee functional disability than iliotibial band and hamstring shortness. Stretching was effective in reducing patellar tilt, patella alta, knee functional disability, increasing knee ROM and hip adduction in these patients. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. The TOPSHOCK study: Effectiveness of radial shockwave therapy compared to focused shockwave therapy for treating patellar tendinopath - design of a randomised controlled trial

    PubMed Central

    2011-01-01

    Background Patellar tendinopathy is a chronic overuse injury of the patellar tendon that is especially prevalent in people who are involved in jumping activities. Extracorporeal Shockwave Therapy is a relatively new treatment modality for tendinopathies. It seems to be a safe and promising part of the rehabilitation program for patellar tendinopathy. Extracorporeal Shockwave Therapy originally used focused shockwaves. Several years ago a new kind of shockwave therapy was introduced: radial shockwave therapy. Studies that investigate the effectiveness of radial shockwave therapy as treatment for patellar tendinopathy are scarce. Therefore the aim of this study is to compare the effectiveness of focussed shockwave therapy and radial shockwave therapy as treatments for patellar tendinopathy. Methods/design The TOPSHOCK study (Tendinopathy Of Patella SHOCKwave) is a two-armed randomised controlled trial in which the effectiveness of focussed shockwave therapy and radial shockwave therapy are directly compared. Outcome assessors and patients are blinded as to which treatment is given. Patients undergo three sessions of either focused shockwave therapy or radial shockwave therapy at 1-week intervals, both in combination with eccentric decline squat training. Follow-up measurements are scheduled just before treatments 2 and 3, and 1, 4, 7 and 12 weeks after the final treatment. The main outcome measure is the Dutch VISA-P questionnaire, which asks for pain, function and sports participation in subjects with patellar tendinopathy. Secondary outcome measures are pain determined with a VAS during ADL, sports and decline squats, rating of subjective improvement and overall satisfaction with the treatment. Patients will also record their sports activities, pain during and after these activities, and concurrent medical treatment on a weekly basis in a web-based diary. Results will be analysed according to the intention-to-treat principle. Discussion The TOPSHOCK study is the

  9. Catastrophic metallosis after tumoral knee prosthesis failure: A case report.

    PubMed

    La Verde, Luca; Fenga, Domenico; Spinelli, Maria Silvia; Campo, Francesco Rosario; Florio, Michela; Rosa, Michele Attilio

    2017-01-01

    Metallosis is a condition characterized by an infiltration of periprosthetic soft tissues and bone by metallic debris resulting from wear or failure of joint arthroplasties. Authors describe a case of a 45-year-old man treated for an osteosarcoma of the distal femur with a modular prosthesis when he was 18 years old, he developed massive metallosis with skin dyspigmentation after 17 years. His medical\\surgical history was remarkable for a left tumoral knee prosthesis implanted 21 years ago. Two years before revision, the patient had a car accident with a two-points prosthesis breakage and despite the surgeon's advice, the patient refused surgery. In two years, prosthesis malfunction caused a progressive catastrophic soft tissues infiltration of metallic debris. Authors suggest that if prosthesis fracture is detected, revision surgery should be attempted as earlier as possible. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  10. Amputation and prosthesis implantation shape body and peripersonal space representations

    PubMed Central

    Canzoneri, Elisa; Marzolla, Marilena; Amoresano, Amedeo; Verni, Gennaro; Serino, Andrea

    2013-01-01

    Little is known about whether and how multimodal representations of the body (BRs) and of the space around the body (Peripersonal Space, PPS) adapt to amputation and prosthesis implantation. In order to investigate this issue, we tested BR in a group of upper limb amputees by means of a tactile distance perception task and PPS by means of an audio-tactile interaction task. Subjects performed the tasks with stimulation either on the healthy limb or the stump of the amputated limb, while wearing or not wearing their prosthesis. When patients performed the tasks on the amputated limb, without the prosthesis, the perception of arm length shrank, with a concurrent shift of PPS boundaries towards the stump. Conversely, wearing the prosthesis increased the perceived length of the stump and extended the PPS boundaries so as to include the prosthetic hand, such that the prosthesis partially replaced the missing limb. PMID:24088746

  11. Internal stresses, dislocation mobility and ductility

    NASA Astrophysics Data System (ADS)

    Saada, G.

    1991-06-01

    The description of plastic deformation must take into account individual mechanisms and heterogeneity of plastic strain. Influence of dislocation interaction with forest dislocations and of cross slip are connected with the organization of dipole walls. The latter are described and their development is explained as a consequence of edge effects. Applications are discussed. La description de la déformation plastique doit prendre en compte les interactions individuelles des dislocations et l'hétérogénéité à grande échelle de la déformation plastique. Les interactions des dislocations mobiles avec la forêt de dislocations, le glissement dévié, ont pour effet la création de parois dipolaires. Celles-ci sont décrites et leur développement est appliqué à partir des effets de bord.

  12. Understanding dislocation mechanics at the mesoscale using phase field dislocation dynamics

    PubMed Central

    Hunter, A.

    2016-01-01

    In this paper, we discuss the formulation, recent developments and findings obtained from a mesoscale mechanics technique called phase field dislocation dynamics (PFDD). We begin by presenting recent advancements made in modelling face-centred cubic materials, such as integration with atomic-scale simulations to account for partial dislocations. We discuss calculations that help in understanding grain size effects on transitions from full to partial dislocation-mediated slip behaviour and deformation twinning. Finally, we present recent extensions of the PFDD framework to alternative crystal structures, such as body-centred cubic metals, and two-phase materials, including free surfaces, voids and bi-metallic crystals. With several examples we demonstrate that the PFDD model is a powerful and versatile method that can bridge the length and time scales between atomistic and continuum-scale methods, providing a much needed understanding of deformation mechanisms in the mesoscale regime. PMID:27002063

  13. Atomistic calculations of dislocation core energy in aluminium

    DOE PAGES

    Zhou, X. W.; Sills, R. B.; Ward, D. K.; ...

    2017-02-16

    A robust molecular dynamics simulation method for calculating dislocation core energies has been developed. This method has unique advantages: it does not require artificial boundary conditions, is applicable for mixed dislocations, and can yield highly converged results regardless of the atomistic system size. Utilizing a high-fidelity bond order potential, we have applied this method in aluminium to calculate the dislocation core energy as a function of the angle β between the dislocation line and Burgers vector. These calculations show that, for the face-centred-cubic aluminium explored, the dislocation core energy follows the same functional dependence on β as the dislocation elasticmore » energy: Ec = A·sin 2β + B·cos 2β, and this dependence is independent of temperature between 100 and 300 K. By further analysing the energetics of an extended dislocation core, we elucidate the relationship between the core energy and radius of a perfect versus extended dislocation. With our methodology, the dislocation core energy can be accurately accounted for in models of plastic deformation.« less

  14. Atomistic calculations of dislocation core energy in aluminium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou, X. W.; Sills, R. B.; Ward, D. K.

    A robust molecular dynamics simulation method for calculating dislocation core energies has been developed. This method has unique advantages: it does not require artificial boundary conditions, is applicable for mixed dislocations, and can yield highly converged results regardless of the atomistic system size. Utilizing a high-fidelity bond order potential, we have applied this method in aluminium to calculate the dislocation core energy as a function of the angle β between the dislocation line and Burgers vector. These calculations show that, for the face-centred-cubic aluminium explored, the dislocation core energy follows the same functional dependence on β as the dislocation elasticmore » energy: Ec = A·sin 2β + B·cos 2β, and this dependence is independent of temperature between 100 and 300 K. By further analysing the energetics of an extended dislocation core, we elucidate the relationship between the core energy and radius of a perfect versus extended dislocation. With our methodology, the dislocation core energy can be accurately accounted for in models of plastic deformation.« less

  15. Comparison of hearing results of nitinol SMART stapes piston prosthesis with conventional piston prostheses: postoperative results of nitinol stapes prosthesis.

    PubMed

    Harris, Jeffrey P; Gong, Shusheng

    2007-08-01

    Recently, a new stapedotomy piston prosthesis, which is a composite metal alloy of nickel and titanium known as nitinol, has been introduced into medical use. This biocompatible alloy has the unique property of shape-memory, which permits tight self-crimping when heat is applied to the wire. To substantiate the favorable initial observations with the SMART piston, this study was undertaken to compare these results (n=26) with those obtained using conventional stainless steel or platinum ribbon prostheses (n=28). Prospective consecutive case review: consecutive cases performed by the same surgeon were analyzed. Tertiary referral center. Fifty-four healthy patients with otosclerosis. Stapedotomy using either SMART prosthesis or conventional prosthesis. Hearing outcomes by audiological assessment. The postoperative hearing mean pure-tone average was 24.81+/-16.20 dBHL for Group 1 (SMART prosthesis) and 27.46+/-15.57 dBHL for Group 2 (conventional prosthesis). Postoperative mean air-bone gap was 7.07+/-8.14 dBHL for Group 1 and 6.38+/-7.54 dBHL for Group 2 using 0.5-, 1-, 2-, and 4-kHz frequencies. When analyzed according to the American Academy of Otolaryngology-Head & Neck Surgery reporting criteria using an estimate of 3 kHz as a mean of the 2-and 4-kHz values, the postoperative mean air-bone gap was 5.42+/-5.4 dBHL for Group 1 SMART and 5.98+/-5.47 dBHL for Group 2 conventional prostheses. Postoperative speech discrimination scores were 96%+/-8.64% and 97%+/-5.9%, respectively. These differences were not shown to be statistically different. Results demonstrate that experienced surgeons may achieve comparable results with both prostheses; however, the ease of self-crimping and the tightness of the crimp may provide advantages that may have long-term benefits. The potential issue of nickel allergy is important when considering patients for this prosthesis.

  16. Preparation for the Implantation of an Intracortical Visual Prosthesis in a Human

    DTIC Science & Technology

    2014-10-01

    Intracortical Visual Prosthesis in a Human PRINCIPAL INVESTIGATOR: Philip R Troyk, PhD... Prosthesis in a Human 5a. CONTRACT NUMBER 5b. GRANT NUMBER W81XWH-12-1-0394 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Philip R Troyk...visual prosthesis (ICVP) for testing in a human. No human trial testing of the prosthesis will occur under the funded work. Preparatory tasks include

  17. Tracheostomy cannulas and voice prosthesis

    PubMed Central

    Kramp, Burkhard; Dommerich, Steffen

    2011-01-01

    Cannulas and voice prostheses are mechanical aids for patients who had to undergo tracheotomy or laryngectomy for different reasons. For better understanding of the function of those artificial devices, first the indications and particularities of the previous surgical intervention are described in the context of this review. Despite the established procedure of percutaneous dilatation tracheotomy e.g. in intensive care units, the application of epithelised tracheostomas has its own position, especially when airway obstruction is persistent (e.g. caused by traumata, inflammations, or tumors) and a longer artificial ventilation or special care of the patient are required. In order to keep the airways open after tracheotomy, tracheostomy cannulas of different materials with different functions are available. For each patient the most appropriate type of cannula must be found. Voice prostheses are meanwhile the device of choice for rapid and efficient voice rehabilitation after laryngectomy. Individual sizes and materials allow adaptation of the voice prostheses to the individual anatomical situation of the patients. The combined application of voice prostheses with HME (Head and Moisture Exchanger) allows a good vocal as well as pulmonary rehabilitation. Precondition for efficient voice prosthesis is the observation of certain surgical principles during laryngectomy. The duration of the prosthesis mainly depends on material properties and biofilms, mostly consisting of funguses and bacteries. The quality of voice with valve prosthesis is clearly superior to esophagus prosthesis or electro-laryngeal voice. Whenever possible, tracheostoma valves for free-hand speech should be applied. Physicians taking care of patients with speech prostheses after laryngectomy should know exactly what to do in case the device fails or gets lost. PMID:22073098

  18. Tracheostomy cannulas and voice prosthesis.

    PubMed

    Kramp, Burkhard; Dommerich, Steffen

    2009-01-01

    Cannulas and voice prostheses are mechanical aids for patients who had to undergo tracheotomy or laryngectomy for different reasons. For better understanding of the function of those artificial devices, first the indications and particularities of the previous surgical intervention are described in the context of this review. Despite the established procedure of percutaneous dilatation tracheotomy e.g. in intensive care units, the application of epithelised tracheostomas has its own position, especially when airway obstruction is persistent (e.g. caused by traumata, inflammations, or tumors) and a longer artificial ventilation or special care of the patient are required. In order to keep the airways open after tracheotomy, tracheostomy cannulas of different materials with different functions are available. For each patient the most appropriate type of cannula must be found. Voice prostheses are meanwhile the device of choice for rapid and efficient voice rehabilitation after laryngectomy. Individual sizes and materials allow adaptation of the voice prostheses to the individual anatomical situation of the patients. The combined application of voice prostheses with HME (Head and Moisture Exchanger) allows a good vocal as well as pulmonary rehabilitation. Precondition for efficient voice prosthesis is the observation of certain surgical principles during laryngectomy. The duration of the prosthesis mainly depends on material properties and biofilms, mostly consisting of funguses and bacteries. The quality of voice with valve prosthesis is clearly superior to esophagus prosthesis or electro-laryngeal voice. Whenever possible, tracheostoma valves for free-hand speech should be applied. Physicians taking care of patients with speech prostheses after laryngectomy should know exactly what to do in case the device fails or gets lost.

  19. Management of long span partially edentulous maxilla with fixed removable denture prosthesis

    PubMed Central

    Jeyavalan, Mahilan I.; Narasimman, M.; Venkatakrishnan, C. J.; Philip, Jacob M.

    2012-01-01

    Restoration of a long span partially edentulous maxilla with tooth supported prosthesis is challenging because of inherent anatomic limitations and unfavourable biomechanics present after the loss of teeth. A tooth supported fixed-removable prosthesis is a treatment option for restoration of such long span partially edentulous maxillary arches. This prosthesis meets the requirements for esthetics, phonetics, comfort, and hygiene, as well as favourable biomechanical stress distribution to the remaining natural tooth abutments. This article presents a procedure for fabrication of a fixed-removable prosthesis that has cement-retained custom cast bar metal substructure and a ball attachment retained removable superstructure prosthesis. PMID:23293488

  20. Management of long span partially edentulous maxilla with fixed removable denture prosthesis.

    PubMed

    Jeyavalan, Mahilan I; Narasimman, M; Venkatakrishnan, C J; Philip, Jacob M

    2012-07-01

    Restoration of a long span partially edentulous maxilla with tooth supported prosthesis is challenging because of inherent anatomic limitations and unfavourable biomechanics present after the loss of teeth. A tooth supported fixed-removable prosthesis is a treatment option for restoration of such long span partially edentulous maxillary arches. This prosthesis meets the requirements for esthetics, phonetics, comfort, and hygiene, as well as favourable biomechanical stress distribution to the remaining natural tooth abutments. This article presents a procedure for fabrication of a fixed-removable prosthesis that has cement-retained custom cast bar metal substructure and a ball attachment retained removable superstructure prosthesis.

  1. Period-doubling reconstructions of semiconductor partial dislocations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, Ji -Sang; Huang, Bing; Wei, Su -Huai

    2015-09-18

    Atomic-scale understanding and control of dislocation cores is of great technological importance, because they act as recombination centers for charge carriers in optoelectronic devices. Using hybrid density-functional calculations, we present period-doubling reconstructions of a 90 degrees partial dislocation in GaAs, for which the periodicity of like-atom dimers along the dislocation line varies from one to two, to four dimers. The electronic properties of a dislocation change drastically with each period doubling. The dimers in the single-period dislocation are able to interact, to form a dispersive one-dimensional band with deep-gap states. However, the inter-dimer interaction for the double-period dislocation becomes significantlymore » reduced; hence, it is free of mid-gap states. The Ga core undergoes a further period-doubling transition to a quadruple-period reconstruction induced by the formation of small hole polarons. In conclusion, the competition between these dislocation phases suggests a new passivation strategy via population manipulation of the detrimental single-period phase.« less

  2. Ultrasonic Study of Dislocation Dynamics in Lithium -

    NASA Astrophysics Data System (ADS)

    Han, Myeong-Deok

    1987-09-01

    Experimental studies of dislocation dynamics in LiF single crystals, using ultrasonic techniques combined with dynamic loading, were performed to investigate the time evolution of the plastic deformation process under a short stress pulse at room temperature, and the temperature dependence of the dislocation damping mechanism in the temperature range 25 - 300(DEGREES)K. From the former, the time dependence of the ultrasonic attenuation was understood as resulting from dislocation multiplication followed by the evolution of mobile dislocations to immobile ones under large stress. From the latter, the temperature dependence of the ultrasonic attenuation was interpreted as due to the motion of the dislocation loops overcoming the periodic Peierls potential barrier in a manner analogous to the motion of a thermalized sine-Gordon chain under a small stress. The Peierls stress obtained from the experimental results by application of Seeger's relaxation model with exponential dislocation length distribution was 4.26MPa, which is consistent with the lowest stress for the linear relation between the dislocation velocity and stress observed by Flinn and Tinder.

  3. 21 CFR 888.3730 - Toe joint phalangeal (hemi-toe) polymer prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Toe joint phalangeal (hemi-toe) polymer prosthesis. 888.3730 Section 888.3730 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... (hemi-toe) polymer prosthesis. (a) Identification. A toe joint phalangeal (hemi-toe) polymer prosthesis...

  4. 21 CFR 888.3730 - Toe joint phalangeal (hemi-toe) polymer prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Toe joint phalangeal (hemi-toe) polymer prosthesis. 888.3730 Section 888.3730 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... (hemi-toe) polymer prosthesis. (a) Identification. A toe joint phalangeal (hemi-toe) polymer prosthesis...

  5. 21 CFR 888.3730 - Toe joint phalangeal (hemi-toe) polymer prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Toe joint phalangeal (hemi-toe) polymer prosthesis. 888.3730 Section 888.3730 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... (hemi-toe) polymer prosthesis. (a) Identification. A toe joint phalangeal (hemi-toe) polymer prosthesis...

  6. 21 CFR 888.3730 - Toe joint phalangeal (hemi-toe) polymer prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Toe joint phalangeal (hemi-toe) polymer prosthesis. 888.3730 Section 888.3730 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... (hemi-toe) polymer prosthesis. (a) Identification. A toe joint phalangeal (hemi-toe) polymer prosthesis...

  7. 21 CFR 888.3730 - Toe joint phalangeal (hemi-toe) polymer prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Toe joint phalangeal (hemi-toe) polymer prosthesis. 888.3730 Section 888.3730 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... (hemi-toe) polymer prosthesis. (a) Identification. A toe joint phalangeal (hemi-toe) polymer prosthesis...

  8. Patellar position in weight-bearing radiographs compared with non-weight-bearing: significance for the detection of osteoarthritis.

    PubMed

    Skou, Nikolaj; Egund, Niels

    2017-03-01

    Background Diagnosis and treatment of patellofemoral disorders including osteoarthritis are currently often based on imaging and clinical assessment with patients in the supine position. Purpose To evaluate differences in patellar position in the trochlear groove and to assess the detection of medial and lateral patellofemoral (PF) osteoarthritis (OA) on axial radiographs in supine and standing positions, respectively. Material and Methods Thirty-five women and 23 men (mean age, 56 years; age range, 18-87 years) referred for routine radiographic examinations of the knees were included. Axial radiographs of the PF joint in both supine non-weight-bearing and standing weight-bearing position in 30° knee flexion were obtained of 111 knees. Measurements performed on the radiographs: patellar tilt, patellar displacement, joint space width, and grade of OA according to Ahlbäck. Results From supine to standing position the patella moved medially and medial joint space width and lateral patellar tilt angle decreased ( P < 0.0001 for the three measured parameters). In the standing position, medial PF OA was observed in 19 knees compared to three knees in the supine position. Fourteen knees had lateral PF OA with almost unchanged grade of OA irrespective of position. Conclusion In weight-bearing positions, the patella is positioned medially in the trochlear groove compared to supine non-weight-bearing positions. Therefore, this study suggests that the common occurrence of medial PF OA can generally not be detected on axial radiographs in supine non-weight-bearing positions and confirms the importance of imaging the PF joint in standing weight-bearing positions.

  9. Preparation for the Implantation of an Intracortical Visual Prosthesis in a Human

    DTIC Science & Technology

    2013-10-01

    Intracortical Visual Prosthesis in a Human PRINCIPAL INVESTIGATOR: Philip R Troyk, PhD... Prosthesis in a Human 5a. CONTRACT NUMBER 5b. GRANT NUMBER W81XWH-12-1-0394 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Philip R Troyk, PhD...to prepare an intracortical visual prosthesis (ICVP) for testing in a human. No human trial testing of the prosthesis will occur under the funded

  10. Vacuum form sheet as a guide for fabrication of orbital prosthesis.

    PubMed

    Dugad, Jinesh A; Dholam, Kanchan P; Chougule, Arati T

    2014-08-01

    Rehabilitation with an orbital prosthesis is done when surgical reconstruction is not possible or affordable in patients with orbital exenteration. Fabrication of orbital prosthesis requires precision in placement of the ocular portion of the prosthesis on the facial moulage. This method describes the use of a vacuum formed sheet for making an orbital template that acts as a guide for achieving optimum orientation of the ocular portion of the prosthesis. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  11. Elasticity and dislocation anelasticity of crystals

    NASA Astrophysics Data System (ADS)

    Nikanorov, S. P.; Kardashev, B. K.

    The book is concerned with the application of the results of physical acoustic studies of elasticity and dislocation anelasticity to the investigation of interatomic interactions and interactions between lattice defects. The analysis of the potential functions determining the energy of interatomic interactions is based on a study of the elastic properties of crystals over a wide temperature range; data on the dislocation structure and on the interaction between dislocations and point defects are based mainly on a study of inelastic effects. Particular attention is given to the relationship between microplastic effects and the initial stage of plastic deformation under conditions of elastic oscillations, when the multiplication of dislocations is negligible.

  12. Biocompatible membrane of PDMS for the new chamber prosthesis stapes.

    PubMed

    Banasik, Katarzyna; Kwacz, Monika

    2016-06-30

    Stapes protheses are designed for patients with otosclerosis resulting immobilization or significant reduction of the stapes mobility. All currently used prostheses are called - piston prosthesis. However, its use to stimulate the cochlea is still imperfect. New chamber stapes prosthesis allows the perilymph excitation more effective than the piston prothesis. Moreover, the chamber prosthesis eliminates the common causes of piston-stapedotomy failures. The most important element of the new prosthesis is a flexible membrane. The membrane stiffness should be close to the stiffness of normal annular ligament. This work presents the process of selection of the membrane's thickness and its manufacturing technology. Method A 3D model of the chamber stapes prosthesis was build using Autodesk Inventor 2015. The model was imported to Abacus 6.13 computing environment. During numerical simulations, displacements corresponding to applied loads were calculated and the membrane thickness was adjusted so that its stiffness was the same as the ligament stiffness (~ 120 N/m). The compliance ratios calculated from the load-displacement curves for the membrane and the annular ligament were verified using linear regression analysis. After determining the thickness, the manufacturing technology of the membrane was developed. Results The best similarity between the membrane's and annular ligament's stiffness was achieved for PDMS membrane with the 0,15- mm thickness (similarity ratio R2=0,997752). In this work, the technological parameters of spin-coating process for membrane manufacture are also presented. Summary The proper functioning of the chamber stapes prosthesis requires the PDMS membrane with a thickness of 0,15 mm. The 0,15-mm membrane has the tiffness close to the stiffness of the normal annular ligament. Therefore, the chamber stapes prosthesis provides the perilymph stimulation at the level comparable to the healthy ear. New prosthesis is currently under pre

  13. Arthroscopic evaluation of patellofemoral congruence with rotation of the knee joint and electrical stimulation of the quadriceps.

    PubMed

    Suganuma, Jun; Mochizuki, Ryuta; Inoue, Yutaka; Kitamura, Kazuya; Honda, Akio

    2014-02-01

    The aim of this study was to investigate the pathoanatomic features of patellar instability by arthroscopically comparing patellofemoral congruence with rotation of the knee joint and/or electrical stimulation of the quadriceps (ESQ) between knees with and without patellar instability. We retrospectively examined 83 knee joints in 83 patients. The joints were classified into 2 groups: group 1 comprised those without a history of patellar dislocation and included 59 patients (25 male and 34 female patients), and group 2 comprised those with a history of patellar dislocation and included 24 patients (9 male and 15 female patients). Evaluation of patellofemoral congruence at 30° of flexion of the knee joint was conducted based on an axial radiograph and arthroscopic findings. The congruence angle was measured on the radiograph. The position of the patellar central ridge (PPCR) on the trochlear groove during arthroscopy was measured using still video frames of knee joints with rotational stress and/or ESQ. Statistical differences in the measurements between the 2 groups were assessed with the unpaired t test and the area under the receiver operating characteristic curve of each measurement. There were significant differences (P < .0001) between the 2 groups in the congruence angle on radiographs and PPCR in knee joints with rotational stress and/or ESQ on arthroscopy. External and internal rotation of the knee joint caused lateral and medial patellar shift, respectively, in both groups, but the shift was significantly larger in group 2. ESQ in addition to rotation caused further patellar shift in group 2 but reduced patellar shift in group 1. Measurement of PPCR with external rotation of the knee and ESQ was the only method to show an area under the receiver operating characteristic curve of 1. There were significant differences in the effects of rotation of the knee joint and/or ESQ on patellofemoral congruence at 30° of flexion of the knee joint on arthroscopy

  14. Design and Control of a Pneumatically Actuated Transtibial Prosthesis.

    PubMed

    Zheng, Hao; Shen, Xiangrong

    2015-04-01

    This paper presents the design and control of a pneumatically actuated transtibial prosthesis, which utilizes a pneumatic cylinder-type actuator to power the prosthetic ankle joint to support the user's locomotion. The pneumatic actuator has multiple advantages over the traditional electric motor, such as light weight, low cost, and high power-to-weight ratio. The objective of this work is to develop a compact and lightweight transtibial prosthesis, leveraging the multiple advantages provided by this highly competitive actuator. In this paper, the design details of the prosthesis are described, including the determination of performance specifications, the layout of the actuation mechanism, and the calculation of the torque capacity. Through the authors' design calculation, the prosthesis is able to provide sufficient range of motion and torque capacity to support the locomotion of a 75 kg individual. The controller design is also described, including the underlying biomechanical analysis and the formulation of the finite-state impedance controller. Finally, the human subject testing results are presented, with the data indicating that the prosthesis is able to generate a natural walking gait and sufficient power output for its amputee user.

  15. Intermanual Transfer Effects in Below-Elbow Myoelectric Prosthesis Users.

    PubMed

    de Boer, Errit; Romkema, Sietske; Cutti, Andrea G; Brouwers, Michael A; Bongers, Raoul M; van der Sluis, Corry K

    2016-11-01

    To determine intermanual transfer effects in patients with a below-elbow amputation using a myoelectric prosthesis and to establish whether laterality affects these effects. Case-control. A standardized setting in a rehabilitation clinic. A convenience sample (N=44) of experienced myoelectric prosthesis users (n=22) and matched controls (n=22). Controls were matched on sex, age (±5y), and hand dominance. Both the experienced group and the control group performed several tasks using a prosthesis simulator attached to their nonaffected arm. Movement time, force control, Box and Block test (BBT) scores, and duration of hand opening. Movement times of myoelectric prosthesis users were shorter, and these users had significantly higher BBT scores and shorter hand opening durations than those of controls. No intermanual transfer effects on force control and no laterality effects were found. Intermanual transfer effects were present in experienced myoelectric prosthesis users with a below-elbow amputation, independent of laterality. These findings support the clinical relevance of intermanual transfer training, which may facilitate persons with an upper limb amputation to start training directly after the amputation. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  16. Design and Control of a Pneumatically Actuated Transtibial Prosthesis

    PubMed Central

    Zheng, Hao; Shen, Xiangrong

    2015-01-01

    This paper presents the design and control of a pneumatically actuated transtibial prosthesis, which utilizes a pneumatic cylinder-type actuator to power the prosthetic ankle joint to support the user's locomotion. The pneumatic actuator has multiple advantages over the traditional electric motor, such as light weight, low cost, and high power-to-weight ratio. The objective of this work is to develop a compact and lightweight transtibial prosthesis, leveraging the multiple advantages provided by this highly competitive actuator. In this paper, the design details of the prosthesis are described, including the determination of performance specifications, the layout of the actuation mechanism, and the calculation of the torque capacity. Through the authors’ design calculation, the prosthesis is able to provide sufficient range of motion and torque capacity to support the locomotion of a 75 kg individual. The controller design is also described, including the underlying biomechanical analysis and the formulation of the finite-state impedance controller. Finally, the human subject testing results are presented, with the data indicating that the prosthesis is able to generate a natural walking gait and sufficient power output for its amputee user. PMID:26146497

  17. Modal analysis of dislocation vibration and reaction attempt frequency

    DOE PAGES

    Sobie, Cameron; Capolungo, Laurent; McDowell, David L.; ...

    2017-02-04

    Transition state theory is a fundamental approach for temporal coarse-graining. It estimates the reaction rate for a transition processes by quantifying the activation free energy and attempt frequency for the unit process. To calculate the transition rate of a gliding dislocation, the attempt frequency is often obtained from line tension estimates of dislocation vibrations, a highly simplified model of dislocation behavior. This work revisits the calculation of attempt frequency for a dislocation bypassing an obstacle, in this case a self-interstitial atom (SIA) loop. First, a direct calculation of the vibrational characteristics of a finite pinned dislocation segment is compared tomore » line tension estimates before moving to the more complex case of dislocation-obstacle bypass. The entropic factor associated with the attempt frequency is calculated for a finite dislocation segment and for an infinite glide dislocation interacting with an SIA loop. Lastly, it is found to be dislocation length independent for three cases of dislocation-self interstitial atom (SIA) loop interactions.« less

  18. A laboratory silicone for preclinical training in ear prosthesis.

    PubMed

    Anand, Vijay; Haribabu; Vimala; Gnanasamband, Vimala

    2013-07-01

    This article describes an industrial elastic silicone as a material for the laboratory fabrication of ear prosthesis. It has been tested for toxicity in lab animals by the SGS India Pvt. Ltd and approved as a material to pass the parameter of abnormal toxicity. This material therefore can be safely recommended for laboratory exercise to fabricate facial prosthesis. The high cost of the maxillo facial silicone materials prohibits their use for facial prosthesis in pre-clinical training of post-graduate students in maxillofacial prosthodontics. For this reason, pre-clinical laboratory exercise in facial prosthesis is inadequate. A few institutions use polymethyl methacrylate resins which are rigid and do not have elastic characteristics of silicone, which is used for facial defects. This cost-effective industrial silicone material which mimics the elastic and color characteristics of the conventional silicones can be recommended for preclinical exercises.

  19. Prosthesis rejection in acquired major upper-limb amputees: a population-based survey.

    PubMed

    Østlie, Kristin; Lesjø, Ingrid Marie; Franklin, Rosemary Joy; Garfelt, Beate; Skjeldal, Ola Hunsbeth; Magnus, Per

    2012-07-01

    To estimate the rates of primary and secondary prosthesis rejection in acquired major upper-limb amputees (ULAs), to describe the most frequently reported reasons for rejection and to estimate the influence of background factors on the risk of rejection. Cross-sectional study analysing population-based questionnaire data (n = 224). Effects were analysed by logistic regression analyses and Cox regression analyses. Primary prosthesis rejection was found in 4.5% whereas 13.4% had discontinued prosthesis use. The main reasons reported for primary non-wear were a perceived lack of need and discrepancies between perceived need and the prostheses available. The main reasons reported for secondary prosthesis rejection were dissatisfaction with prosthetic comfort, function and control. Primary prosthesis rejection was more likely in ULAs amputated at high age and in ULAs with proximal amputations. Secondary prosthesis rejection was more likely in proximal ULAs and in women. Clinicians should be aware of the increased risk of rejection in proximal ULAs, elderly ULAs and in women. Emphasising individual needs will probably facilitate successful prosthetic fitting. Improved prosthesis quality and individualised prosthetic training may increase long-term prosthesis use. Further studies of the effect of prosthetic training and of the reasons for rejection of different prosthetic types are suggested.

  20. Comparing the effects of eccentric training with eccentric training and static stretching exercises in the treatment of patellar tendinopathy. A controlled clinical trial.

    PubMed

    Dimitrios, Stasinopoulos; Pantelis, Manias; Kalliopi, Stasinopoulou

    2012-05-01

    The aim of the present study was to investigate the effectiveness of eccentric training and eccentric training with static stretching exercises in the management of patellar tendinopathy. Controlled clinical trial. Rheumatology and rehabilitation centre. Forty-three patients who had patellar tendinopathy for at least three months. They were allocated to two groups by alternative allocation. Group A (n = 22) was treated with eccentric training of patellar tendon and static stretching exercises of quadriceps and hamstrings and Group B (n = 21) received eccentric training of patellar tendon. All patients received five treatments per week for four weeks. Pain and function were evaluated using the VISA-P score at baseline, at the end of treatment (week 4), and six months (week 24) after the end of treatment. At the end of treatment, there was a rise in VISA-P score in both groups compared with baseline (P<0.0005, paired t test). There were significant differences in the VISA-P score between the groups at the end of treatment (+14; 10 to 18) and at the six-month follow-up (+19; 13 to 24); eccentric training and static stretching exercises produced the largest effect (P<0.0005, one-way ANOVA). Eccentric training and static stretching exercises is superior to eccentric training alone to reduce pain and improve function in patients with patellar tendinopathy at the end of the treatment and at follow-up.

  1. Growth and dislocation studies of β-HMX.

    PubMed

    Gallagher, Hugh G; Sherwood, John N; Vrcelj, Ranko M

    2014-01-01

    The defect structure of organic materials is important as it plays a major role in their crystal growth properties. It also can play a subcritical role in "hot-spot" detonation processes of energetics and one such energetic is cyclotetramethylene-tetranitramine, in the commonly used beta form (β-HMX). The as-grown crystals grown by evaporation from acetone show prismatic, tabular and columnar habits, all with {011}, {110}, (010) and (101) faces. Etching on (010) surfaces revealed three different types of etch pits, two of which could be identified with either pure screw or pure edge dislocations, the third is shown to be an artifact of the twinning process that this material undergoes. Examination of the {011} and {110} surfaces show only one type of etch pit on each surface; however their natural asymmetry precludes the easy identification of their Burgers vector or dislocation type. Etching of cleaved {011} surfaces demonstrates that the etch pits can be associated with line dislocations. All dislocations appear randomly on the crystal surfaces and do not form alignments characteristic of mechanical deformation by dislocation slip. Crystals of β-HMX grown from acetone show good morphological agreement with that predicted by modelling, with three distinct crystal habits observed depending upon the supersaturation of the growth solution. Prismatic habit was favoured at low supersaturation, while tabular and columnar crystals were predominant at higher super saturations. The twin plane in β-HMX was identified as a (101) reflection plane. The low plasticity of β-HMX is shown by the lack of etch pit alignments corresponding to mechanically induced dislocation arrays. On untwinned {010} faces, two types of dislocations exist, pure edge dislocations with b = [010] and pure screw dislocations with b = [010]. On twinned (010) faces, a third dislocation type exists and it is proposed that these pits are associated with pure screw dislocations with b = [010

  2. Statistics of dislocation pinning at localized obstacles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dutta, A.; Bhattacharya, M., E-mail: mishreyee@vecc.gov.in; Barat, P.

    2014-10-14

    Pinning of dislocations at nanosized obstacles like precipitates, voids, and bubbles is a crucial mechanism in the context of phenomena like hardening and creep. The interaction between such an obstacle and a dislocation is often studied at fundamental level by means of analytical tools, atomistic simulations, and finite element methods. Nevertheless, the information extracted from such studies cannot be utilized to its maximum extent on account of insufficient information about the underlying statistics of this process comprising a large number of dislocations and obstacles in a system. Here, we propose a new statistical approach, where the statistics of pinning ofmore » dislocations by idealized spherical obstacles is explored by taking into account the generalized size-distribution of the obstacles along with the dislocation density within a three-dimensional framework. Starting with a minimal set of material parameters, the framework employs the method of geometrical statistics with a few simple assumptions compatible with the real physical scenario. The application of this approach, in combination with the knowledge of fundamental dislocation-obstacle interactions, has successfully been demonstrated for dislocation pinning at nanovoids in neutron irradiated type 316-stainless steel in regard to the non-conservative motion of dislocations. An interesting phenomenon of transition from rare pinning to multiple pinning regimes with increasing irradiation temperature is revealed.« less

  3. 21 CFR 874.3730 - Laryngeal prosthesis (Taub design).

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Laryngeal prosthesis (Taub design). 874.3730 Section 874.3730 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Prosthetic Devices § 874.3730 Laryngeal prosthesis (Taub design). (a) Identification. A...

  4. Reading Visual Braille with a Retinal Prosthesis

    PubMed Central

    Lauritzen, Thomas Z.; Harris, Jordan; Mohand-Said, Saddek; Sahel, Jose A.; Dorn, Jessy D.; McClure, Kelly; Greenberg, Robert J.

    2012-01-01

    Retinal prostheses, which restore partial vision to patients blinded by outer retinal degeneration, are currently in clinical trial. The Argus II retinal prosthesis system was recently awarded CE approval for commercial use in Europe. While retinal prosthesis users have achieved remarkable visual improvement to the point of reading letters and short sentences, the reading process is still fairly cumbersome. This study investigates the possibility of using an epiretinal prosthesis to stimulate visual braille as a sensory substitution for reading written letters and words. The Argus II retinal prosthesis system, used in this study, includes a 10 × 6 electrode array implanted epiretinally, a tiny video camera mounted on a pair of glasses, and a wearable computer that processes the video and determines the stimulation current of each electrode in real time. In the braille reading system, individual letters are created by a subset of dots from a 3 by 2 array of six dots. For the visual braille experiment, a grid of six electrodes was chosen out of the 10 × 6 Argus II array. Groups of these electrodes were then directly stimulated (bypassing the camera) to create visual percepts of individual braille letters. Experiments were performed in a single subject. Single letters were stimulated in an alternative forced choice (AFC) paradigm, and short 2–4-letter words were stimulated (one letter at a time) in an open-choice reading paradigm. The subject correctly identified 89% of single letters, 80% of 2-letter, 60% of 3-letter, and 70% of 4-letter words. This work suggests that text can successfully be stimulated and read as visual braille in retinal prosthesis patients. PMID:23189036

  5. Reading visual braille with a retinal prosthesis.

    PubMed

    Lauritzen, Thomas Z; Harris, Jordan; Mohand-Said, Saddek; Sahel, Jose A; Dorn, Jessy D; McClure, Kelly; Greenberg, Robert J

    2012-01-01

    Retinal prostheses, which restore partial vision to patients blinded by outer retinal degeneration, are currently in clinical trial. The Argus II retinal prosthesis system was recently awarded CE approval for commercial use in Europe. While retinal prosthesis users have achieved remarkable visual improvement to the point of reading letters and short sentences, the reading process is still fairly cumbersome. This study investigates the possibility of using an epiretinal prosthesis to stimulate visual braille as a sensory substitution for reading written letters and words. The Argus II retinal prosthesis system, used in this study, includes a 10 × 6 electrode array implanted epiretinally, a tiny video camera mounted on a pair of glasses, and a wearable computer that processes the video and determines the stimulation current of each electrode in real time. In the braille reading system, individual letters are created by a subset of dots from a 3 by 2 array of six dots. For the visual braille experiment, a grid of six electrodes was chosen out of the 10 × 6 Argus II array. Groups of these electrodes were then directly stimulated (bypassing the camera) to create visual percepts of individual braille letters. Experiments were performed in a single subject. Single letters were stimulated in an alternative forced choice (AFC) paradigm, and short 2-4-letter words were stimulated (one letter at a time) in an open-choice reading paradigm. The subject correctly identified 89% of single letters, 80% of 2-letter, 60% of 3-letter, and 70% of 4-letter words. This work suggests that text can successfully be stimulated and read as visual braille in retinal prosthesis patients.

  6. Dislocations and other topological oddities

    NASA Astrophysics Data System (ADS)

    Pieranski, Pawel

    2016-03-01

    We will show that the book Dislocations by Jacques Friedel, published half a century ago, can still be recommended, in agreement with the author's intention, as a textbook ;for research students at University and for students at engineering schools as well as for research engineers;. Indeed, today dislocations are known to occur not only in solid crystals but also in many other systems discovered more recently such as colloidal crystals or liquid crystals having periodic structures. Moreover, the concept of dislocations is an excellent starting point for lectures on topological defects occurring in systems equipped with order parameters resulting from broken symmetries: disclinations in nematic or hexatic liquid crystals, dispirations in chiral smectics or disorientations in lyotropic liquid crystals. The discussion of dislocations in Blue Phases will give us an opportunity to call on mind Sir Charles Frank, friend of Jacques Friedel since his Bristol years, who called these ephemeral mesophases ;topological oddities;. Being made of networks of disclinations, Blue Phases are similar to Twist Grain Boundary (TGB) smectic phases, which are made of networks of screw dislocations and whose existence was predicted by de Gennes in 1972 on the basis of the analogy between smectics and superconductors. We will stress that the book by Jacques Friedel contains seeds of this analogy.

  7. Control and Evaluation of a Powered Transfemoral Prosthesis for Stair Ascent.

    PubMed

    Ledoux, Elissa D; Goldfarb, Michael

    2017-07-01

    This paper assesses the metabolic effort exerted by three transfemoral amputees, when using a powered knee and ankle prosthesis for stair ascent, relative to ascending stairs with passive knee and ankle prostheses. The paper describes a controller that provides step-over stair ascent behavior reflective of healthy stair ascent biomechanics, and describes its implementation in a powered prosthesis prototype. Stair ascent experiments were performed with three unilateral transfemoral amputee subjects, comparing the oxygen consumption required to ascend stairs using the powered prosthesis (with a step-over gait), relative to using their daily-use energetically passive prostheses (with a step-to gait). Results indicate on average a 24% reduction in oxygen consumption and a 30% reduction in stair ascent timewhen using the powered prosthesis, relative to when using the passive prostheses. All subjects expressed a strong preference for ascending stairs using the powered prosthesis.

  8. Automated identification and indexing of dislocations in crystal interfaces

    DOE PAGES

    Stukowski, Alexander; Bulatov, Vasily V.; Arsenlis, Athanasios

    2012-10-31

    Here, we present a computational method for identifying partial and interfacial dislocations in atomistic models of crystals with defects. Our automated algorithm is based on a discrete Burgers circuit integral over the elastic displacement field and is not limited to specific lattices or dislocation types. Dislocations in grain boundaries and other interfaces are identified by mapping atomic bonds from the dislocated interface to an ideal template configuration of the coherent interface to reveal incompatible displacements induced by dislocations and to determine their Burgers vectors. Additionally, the algorithm generates a continuous line representation of each dislocation segment in the crystal andmore » also identifies dislocation junctions.« less

  9. Worker Dislocation and Its Consequences.

    ERIC Educational Resources Information Center

    Rosenbaum, Allan; Zirkin, Barbara G.

    A study examined the socioeconomic characteristcs, family and social supportive services, economic and social difficulties, education and training levels, and ways in which dislocated workers in Maryland found reemployment. Data were collected from in-depth personal interviews with 9 dislocated workers, questionnaires administered to 45 unemployed…

  10. Atomistic simulations of dislocation pileup: Grain boundaries interaction

    DOE PAGES

    Wang, Jian

    2015-05-27

    Here, using molecular dynamics (MD) simulations, we studied the dislocation pileup–grain boundary (GB) interactions. Two Σ11 asymmetrical tilt grain boundaries in Al are studied to explore the influence of orientation relationship and interface structure on dislocation activities at grain boundaries. To mimic the reality of a dislocation pileup in a coarse-grained polycrystalline, we optimized the dislocation population in MD simulations and developed a predict-correct method to create a dislocation pileup in MD simulations. MD simulations explored several kinetic processes of dislocations–GB reactions: grain boundary sliding, grain boundary migration, slip transmission, dislocation reflection, reconstruction of grain boundary, and the correlation ofmore » these kinetic processes with the available slip systems across the GB and atomic structures of the GB.« less

  11. Simulation of a slope adapting ankle prosthesis provided by semi-active damping.

    PubMed

    LaPrè, Andrew K; Sup, Frank

    2011-01-01

    Modern passive prosthetic foot/ankles cannot adapt to variations in ground slope. The lack of active adaptation significantly compromises an amputee's balance and stability on uneven terrains. To address this deficit, this paper proposes an ankle prosthesis that uses semi-active damping as a mechanism to provide active slope adaptation. The conceptual ankle prosthesis consists of a modulated damper in series with a spring foot that allows the foot to conform to the angle of the surface in the sagittal plane. In support of this approach, biomechanics data is presented showing unilateral transtibial amputees stepping on a wedge with their daily-use passive prosthesis. Based on this data, a simulation of the ankle prosthesis with semi-active damping is developed. The model shows the kinematic adaptation of the prosthesis to sudden changes in ground slope. The results show the potential of an ankle prosthesis with semi-active damping to actively adapt to the ground slope at each step.

  12. Electron energy can oscillate near a crystal dislocation

    DOE PAGES

    Li, Mingda; Cui, Wenping; Dresselhaus, Mildred S.; ...

    2017-01-25

    Crystal dislocations govern the plastic mechanical properties of materials but also affect the electrical and optical properties. However, a fundamental and quantitative quantum field theory of a dislocation has remained undiscovered for decades. Here in this article we present an exactly-solvable one-dimensional quantum field theory of a dislocation, for both edge and screw dislocations in an isotropic medium, by introducing a new quasiparticle which we have called the ‘dislon’. The electron-dislocation relaxation time can then be studied directly from the electron self-energy calculation, which is reducible to classical results. In addition, we predict that the electron energy will experience anmore » oscillation pattern near a dislocation. Compared with the electron density’s Friedel oscillation, such an oscillation is intrinsically different since it exists even with only single electron is present. With our approach, the effect of dislocations on materials’ non-mechanical properties can be studied at a full quantum field theoretical level.« less

  13. Use of Powered Prosthesis for Children with Upper Limb Deficiency at Hyogo Rehabilitation Center

    PubMed Central

    Shibata, Yaeko; Mizobe, Futoshi

    2015-01-01

    Background There has been no research investigating the use of powered prosthetic for children in Japan. Objective To gain better insight into the state of powered prosthesis usage and identify a ratio of rejection among children. Methods Subjects were 37 unilateral below elbow amputees between the ages of 0 and 16 at the time of their first experienced fitting with a powered prosthesis at our Center. The information was collected from medical records and through face-to-face interviews, and we examined rejection rate and the factors affecting the use of powered prosthesis. Results The rate of discontinuation was 21.6% as 8 of the 37 children stopped using powered prosthesis. All of them were fitted their prosthesis after 2 years of age, and they rejected prosthesis between 5 to 19 years. We found that the level of amputation had no influence on the use of a powered prosthesis. Conclusions Children fitted before 2 years of age tend to accept their powered prosthesis than those fitted after 2 years. Multidisciprinary team approach, adequate rehabilitation, detailed follow-up and involvement of parents are quite important for introducing powered prosthesis for children. PMID:26125974

  14. Use of Powered Prosthesis for Children with Upper Limb Deficiency at Hyogo Rehabilitation Center.

    PubMed

    Toda, Mitsunori; Chin, Takaaki; Shibata, Yaeko; Mizobe, Futoshi

    2015-01-01

    There has been no research investigating the use of powered prosthetic for children in Japan. To gain better insight into the state of powered prosthesis usage and identify a ratio of rejection among children. Subjects were 37 unilateral below elbow amputees between the ages of 0 and 16 at the time of their first experienced fitting with a powered prosthesis at our Center. The information was collected from medical records and through face-to-face interviews, and we examined rejection rate and the factors affecting the use of powered prosthesis. The rate of discontinuation was 21.6% as 8 of the 37 children stopped using powered prosthesis. All of them were fitted their prosthesis after 2 years of age, and they rejected prosthesis between 5 to 19 years. We found that the level of amputation had no influence on the use of a powered prosthesis. Children fitted before 2 years of age tend to accept their powered prosthesis than those fitted after 2 years. Multidisciprinary team approach, adequate rehabilitation, detailed follow-up and involvement of parents are quite important for introducing powered prosthesis for children.

  15. Prosthesis Prescription Protocol of the Arm (PPP-Arm): The implementation of a national prosthesis prescription protocol.

    PubMed

    Wijdenes, Paula; Brouwers, Michael; van der Sluis, Corry K

    2018-02-01

    In order to create more uniformity in the prescription of upper limb prostheses by Dutch rehabilitation teams, the development and implementation of a Prosthesis Prescription Protocol of the upper limb (PPP-Arm) was initiated. The aim was to create a national digital protocol to structure, underpin, and evaluate the prescription of upper limb prostheses for clients with acquired or congenital arm defects. Prosthesis Prescription Protocol of the Arm (PPP-Arm) was developed on the basis of the International Classification of Functioning and consisted of several layers. All stakeholders (rehabilitation teams, orthopedic workshops, patients, and insurance companies) were involved in development and implementation. A national project coordinator and knowledge brokers in each team were essential for the project. PPP-Arm was successfully developed and implemented in nine Dutch rehabilitation teams. The protocol improved team collaboration, structure, and completeness of prosthesis prescriptions and treatment uniformity and might be interesting for other countries as well. Clinical relevance A national protocol to prescribe upper limb prostheses can be helpful to create uniformity in treatment of patients with upper limb defects. Such a protocol improves quality of care for all patients in the country.

  16. Knee Dislocations in Sports Injuries

    PubMed Central

    Pardiwala, Dinshaw N; Rao, Nandan N; Anand, Karthik; Raut, Alhad

    2017-01-01

    Knee dislocations are devastating when they occur on the athletic field or secondary to motor sports. The complexity of presentation and spectrum of treatment options makes these injuries unique and extremely challenging to even the most experienced knee surgeons. An astute appreciation of the treatment algorithm is essential to plan individualized management since no two complex knee dislocations are ever the same. Moreover, attention to detail and finesse of surgical technique are required to obtain a good functional result and ensure return to play. Over the past 10 years, our service has treated 43 competitive sportsmen with knee dislocations, and this experience forms the basis for this narrative review. PMID:28966379

  17. Design of a power-asymmetric actuator for a transtibial prosthesis.

    PubMed

    Bartlett, Harrison L; Lawson, Brian E; Goldfarb, Michael

    2017-07-01

    This paper presents the design and characterization of a power-asymmetric actuator for a transtibial prosthesis. The device is designed to provide the combination of: 1) joint locking, 2) high power dissipation, and 3) low power generation. This actuator functionality allows for a prosthesis to be designed with minimal mass and power consumption relative to a fully-powered robotic prosthesis while maintaining much of the functionality necessary for activities of daily living. The actuator achieves these design characteristics while maintaining a small form factor by leveraging a combination of electromechanical and hydraulic components. The design of the actuator is described herein, and results of an experimental characterization are provided that indicate that the actuator is capable of providing the functional capabilities required of an ankle prosthesis in a compact and lightweight package.

  18. Creep Deformation by Dislocation Movement in Waspaloy

    PubMed Central

    Whittaker, Mark; Harrison, Will; Deen, Christopher; Rae, Cathie; Williams, Steve

    2017-01-01

    Creep tests of the polycrystalline nickel alloy Waspaloy have been conducted at Swansea University, for varying stress conditions at 700 °C. Investigation through use of Transmission Electron Microscopy at Cambridge University has examined the dislocation networks formed under these conditions, with particular attention paid to comparing tests performed above and below the yield stress. This paper highlights how the dislocation structures vary throughout creep and proposes a dislocation mechanism theory for creep in Waspaloy. Activation energies are calculated through approaches developed in the use of the recently formulated Wilshire Equations, and are found to differ above and below the yield stress. Low activation energies are found to be related to dislocation interaction with γ′ precipitates below the yield stress. However, significantly increased dislocation densities at stresses above yield cause an increase in the activation energy values as forest hardening becomes the primary mechanism controlling dislocation movement. It is proposed that the activation energy change is related to the stress increment provided by work hardening, as can be observed from Ti, Ni and steel results. PMID:28772421

  19. Te homogeneous precipitation in Ge dislocation loop vicinity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perrin Toinin, J.; Portavoce, A., E-mail: alain.portavoce@im2np.fr; Texier, M.

    2016-06-06

    High resolution microscopies were used to study the interactions of Te atoms with Ge dislocation loops, after a standard n-type doping process in Ge. Te atoms neither segregate nor precipitate on dislocation loops, but form Te-Ge clusters at the same depth as dislocation loops, in contradiction with usual dopant behavior and thermodynamic expectations. Atomistic kinetic Monte Carlo simulations show that Te atoms are repulsed from dislocation loops due to elastic interactions, promoting homogeneous Te-Ge nucleation between dislocation loops. This phenomenon is enhanced by coulombic interactions between activated Te{sup 2+} or Te{sup 1+} ions.

  20. Prosthesis Material

    NASA Technical Reports Server (NTRS)

    2004-01-01

    In this photograph, Amputee Amie Bradly uses a NASA-developed prosthesis to paint her fingernails. Derived from foam insulation technology used to protect the Space Shuttle External Tank from excessive heat, FAB/CAD, a subsidiary of the Harshberger Prosthetic and Orthotic Center, utilized the technology to replace the heavy, fragile plaster they used to produce master molds for prosthetics. The new material was lighter, cheaper and easier to manufacture than plaster, resulting in lower costs to the customer.

  1. Prosthesis Material

    NASA Technical Reports Server (NTRS)

    1995-01-01

    In this photograph, James Carden uses a NASA-developed prosthesis to moved planks around his home. Derived from foam insulation technology used to protect the Space Shuttle External Tank from excessive heat, FAB/CAD, a subsidiary of the Harshberger Prosthetic and Orthotic Center, utilized the technology to replace the heavy, fragile plaster they used to produce master molds for prosthetics. The new material was lighter, cheaper and easier to manufacture than plaster, resulting in lower costs to the customer.

  2. Prosthesis Material

    NASA Technical Reports Server (NTRS)

    1995-01-01

    In this photograph, Sandra Rossi user her NASA-developed prosthesis for the first time. Derived from foam insulation technology used to protect the Space Shuttle External Tank from excessive heat, FAB/CAD, a subsidiary of the Harshberger Prosthetic and Orthotic Center, utilized the technology to replace the heavy, fragile plaster they used to produce master molds for prosthetics. The new material was lighter, cheaper and easier to manufacture than plaster, resulting in lower costs to the customer.

  3. Dislocated Shoulder

    MedlinePlus

    ... up of three bones: your collarbone, your shoulder blade, and your upper arm bone. The top of ... fits into a cuplike socket in your shoulder blade. A shoulder dislocation is an injury that happens ...

  4. 3D discrete dislocation dynamics study of creep behavior in Ni-base single crystal superalloys by a combined dislocation climb and vacancy diffusion model

    NASA Astrophysics Data System (ADS)

    Gao, Siwen; Fivel, Marc; Ma, Anxin; Hartmaier, Alexander

    2017-05-01

    A three-dimensional (3D) discrete dislocation dynamics (DDD) creep model is developed to investigate creep behavior under uniaxial tensile stress along the crystallographic [001] direction in Ni-base single crystal superalloys, which takes explicitly account of dislocation glide, climb and vacancy diffusion, but neglects phase transformation like rafting of γ‧ precipitates. The vacancy diffusion model takes internal stresses by dislocations and mismatch strains into account and it is coupled to the dislocation dynamics model in a numerically efficient way. This model is helpful for understanding the fundamental creep mechanisms in superalloys and clarifying the effects of dislocation glide and climb on creep deformation. In cases where the precipitate cutting rarely occurs, e.g. due to the high anti-phase boundary energy and the lack of superdislocations, the dislocation glide in the γ matrix and the dislocation climb along the γ/γ‧ interface dominate plastic deformation. The simulation results show that a high temperature or a high stress both promote dislocation motion and multiplication, so as to cause a large creep strain. Dislocation climb accelerated by high temperature only produces a small plastic strain, but relaxes the hardening caused by the filling γ channels and lets dislocations further glide and multiply. The strongest variation of vacancy concentration occurs in the horizontal channels, where more mixed dislocations exit and tend to climb. The increasing internal stresses due to the increasing dislocation density are easily overcome by dislocations under a high external stress that leads to a long-term dislocation glide accompanied by multiplication.

  5. Postpneumonectomy syndrome in children: advantages and long-term follow-up of expandable prosthesis.

    PubMed

    Podevin, G; Larroquet, M; Camby, C; Audry, G; Plattner, V; Heloury, Y

    2001-09-01

    Pneumonectomy in children can be complicated by a severe mediastinal shift, which leads to bronchial stretching resulting in severe respiratory failure. This postpneumonectomy syndrome can be corrected by inserting a prosthesis in the empty side of the chest. Forty-two children, from 6 months to 15 years old, underwent a pneumonectomy. Seven of these patients were treated surgically for severe manifestations of postpneumonectomy syndrome. First insertion of an expandable prosthesis was followed up in 5 cases by its replacement with a breast prosthesis in adolescence. The expandable prosthesis was injected periodically with saline solution to maintain the mediastinum in a midline position as the children grew. The mean delay between pneumonectomy and first prosthesis implantation was 5 years (range, 11 months to 8 years). Pulmonary function tests showed a substantial improvement in the obstructive syndrome in all patients except one, in whom the functional improvement was moderate. The mean follow-up after the expandable prosthesis implantation was 6 years (range, 6 months to 10 years) and all patients are doing well. The insertion of an intrathoracic prosthesis can dramatically improve the clinical symptoms and reduce the functional obstructive syndrome. The expandable prosthesis allowed for progressive, well-tolerated recentering of the mediastinum and adjustment for growth. Copyright 2001 by W.B. Saunders Company.

  6. Cranioplasty prosthesis manufacturing based on reverse engineering technology

    PubMed Central

    Chrzan, Robert; Urbanik, Andrzej; Karbowski, Krzysztof; Moskała, Marek; Polak, Jarosław; Pyrich, Marek

    2012-01-01

    Summary Background Most patients with large focal skull bone loss after craniectomy are referred for cranioplasty. Reverse engineering is a technology which creates a computer-aided design (CAD) model of a real structure. Rapid prototyping is a technology which produces physical objects from virtual CAD models. The aim of this study was to assess the clinical usefulness of these technologies in cranioplasty prosthesis manufacturing. Material/Methods CT was performed on 19 patients with focal skull bone loss after craniectomy, using a dedicated protocol. A material model of skull deficit was produced using computer numerical control (CNC) milling, and individually pre-operatively adjusted polypropylene-polyester prosthesis was prepared. In a control group of 20 patients a prosthesis was manually adjusted to each patient by a neurosurgeon during surgery, without using CT-based reverse engineering/rapid prototyping. In each case, the prosthesis was implanted into the patient. The mean operating times in both groups were compared. Results In the group of patients with reverse engineering/rapid prototyping-based cranioplasty, the mean operating time was shorter (120.3 min) compared to that in the control group (136.5 min). The neurosurgeons found the new technology particularly useful in more complicated bone deficits with different curvatures in various planes. Conclusions Reverse engineering and rapid prototyping may reduce the time needed for cranioplasty neurosurgery and improve the prosthesis fitting. Such technologies may utilize data obtained by commonly used spiral CT scanners. The manufacturing of individually adjusted prostheses should be commonly used in patients planned for cranioplasty with synthetic material. PMID:22207125

  7. Replacement of the valvular prosthesis in a patient with a Bentall procedure.

    PubMed

    Panos, A L; Teoh, K T; Wilson, J K; Salerno, T A

    1992-09-01

    Patients who have had the Bentall-DeBono procedure using a composite conduit with a tissue valvular prosthesis pose a great challenge when problems develop with the tissue prosthesis. We herein report the surgical management of one such case, in which the valvular prosthesis was removed and replaced without replacement of the conduit.

  8. Dislocation nucleation facilitated by atomic segregation

    NASA Astrophysics Data System (ADS)

    Zou, Lianfeng; Yang, Chaoming; Lei, Yinkai; Zakharov, Dmitri; Wiezorek, Jörg M. K.; Su, Dong; Yin, Qiyue; Li, Jonathan; Liu, Zhenyu; Stach, Eric A.; Yang, Judith C.; Qi, Liang; Wang, Guofeng; Zhou, Guangwen

    2018-01-01

    Surface segregation--the enrichment of one element at the surface, relative to the bulk--is ubiquitous to multi-component materials. Using the example of a Cu-Au solid solution, we demonstrate that compositional variations induced by surface segregation are accompanied by misfit strain and the formation of dislocations in the subsurface region via a surface diffusion and trapping process. The resulting chemically ordered surface regions acts as an effective barrier that inhibits subsequent dislocation annihilation at free surfaces. Using dynamic, atomic-scale resolution electron microscopy observations and theory modelling, we show that the dislocations are highly active, and we delineate the specific atomic-scale mechanisms associated with their nucleation, glide, climb, and annihilation at elevated temperatures. These observations provide mechanistic detail of how dislocations nucleate and migrate at heterointerfaces in dissimilar-material systems.

  9. BBilateral Neglected Anterior Shoulder Dislocation with Greater Tuberosity Fractures

    PubMed Central

    Upasani, Tejas; Bhatnagar, Abhinav; Mehta, Sonu

    2016-01-01

    Introduction: Shoulder dislocations are a very common entity in routine orthopaedic practice. Chronic unreduced anterior dislocations of the shoulder are not very common. Neurological and vascular complications may occur as a result of an acute anterior dislocation of the shoulder or after a while in chronic unreduced shoulder dislocation. Open reduction is indicated for most chronic shoulder dislocations. We report a case of neglected bilateral anterior shoulder dislocation with bilateral displaced greater tuberosity fracture. To the best of our knowledge, only a handful cases have been reported in literature with bilateral anterior shoulder dislocation with bilateral fractures. Delayed diagnosis/reporting is a scenario which makes the list even slimmer and management all the more challenging. Case Report: We report a case of a 35-year-old male who had bilateral anterior shoulder dislocation and bilateral greater tuberosity fracture post seizure and failed to report it for a period of 30 days. One side was managed conservatively with closed reduction and immobilization and the other side with open reduction. No neurovascular complications pre or post reduction of shoulder were seen. Conclusion: Shoulder dislocations should always be suspected post seizures and if found should be treated promptly. Treatment becomes difficult for any shoulder dislocation that goes untreated for considerable period of time PMID:27703939

  10. Implantable multilayer microstrip antenna for retinal prosthesis: antenna testing.

    PubMed

    Permana, Hans; Fang, Qiang; Rowe, Wayne S T

    2012-01-01

    Retinal prosthesis has come to a more mature stage and become a very strategic answer to Retinitis Pigmentosa (RP) and Age-related Macular Degeneration (AMD) diseases. In a retinal prosthesis system, wireless link holds a great importance for the continuity of the system. In this paper, an implantable multilayer microstrip antenna was proposed for the retinal prosthesis system. Simulations were performed in High Frequency Structure Simulator (HFSS) with the surrounding material of air and Vitreous Humor fluid. The fabricated antenna was measured for characteristic validation in free space. The results showed that the real antenna possessed similar return loss and radiation pattern, while there was discrepancy with the gain values.

  11. Fitting a hand-glove prosthesis to enhance the reconstructed mutilated hand.

    PubMed

    Leow, M E; Kour, A K; Pereira, B P; Pho, R W

    1998-03-01

    Microsurgical reconstruction of the severely mutilated hand aimed at improving prehensile functions often does not address the esthetic aspects of the hand. The poor appearance of the reconstructed hand affects its active display and use. A hand-glove prosthesis may be prescribed in this instance to enhance the overall form and function of the mutilated hand. We reviewed 16 cases of mutilating hand injuries in which surgical reconstructions were performed and the patients were subsequently fitted with a hand-glove prosthesis to augment the outcome. An improved appearance was achieved in all patients fitted with the prosthesis. The patients' sense of confidence was also enhanced, which in turn promoted the active and open use of the reconstructed hands. While prescribed primarily to improve the appearance of the reconstructed hands, these prostheses were documented to enhance the physical hand functions in 11 cases by increasing the span of the hand and providing an opposable post and a palmar base for holding and for anchorage. The prosthesis enhanced assistive functions of the reconstructed hands and freed the contralateral normal hand for use in bimanual activities, such as holding a wallet and taking out money, supporting a note pad for writing, and holding a plate at buffet receptions. At the 18-month follow-up visit, 13 (87%) of the patients continued to use their prosthesis. Wear and tear were problems associated with the frequent use of the prosthesis. The expected life span of the prosthesis with daily use ranged from 2 to 3 years. All the patients acknowledged that the prosthesis played a role in their rehabilitation and that it helped them to overcome the initial psychological trauma and to come to terms with their physical loss.

  12. Unravelling the physics of size-dependent dislocation-mediated plasticity

    NASA Astrophysics Data System (ADS)

    El-Awady, Jaafar A.

    2015-01-01

    Size-affected dislocation-mediated plasticity is important in a wide range of materials and technologies. Here we develop a generalized size-dependent dislocation-based model that predicts strength as a function of crystal/grain size and the dislocation density. Three-dimensional (3D) discrete dislocation dynamics (DDD) simulations reveal the existence of a well-defined relationship between strength and dislocation microstructure at all length scales for both single crystals and polycrystalline materials. The results predict a transition from dislocation-source strengthening to forest-dominated strengthening at a size-dependent critical dislocation density. It is also shown that the Hall-Petch relationship can be physically interpreted by coupling with an appropriate kinetic equation of the evolution of the dislocation density in polycrystals. The model is shown to be in remarkable agreement with experiments. This work presents a micro-mechanistic framework to predict and interpret strength size-scale effects, and provides an avenue towards performing multiscale simulations without ad hoc assumptions.

  13. Function of obturator prosthesis after maxillectomy and prosthetic obturator rehabilitation.

    PubMed

    Chen, Cheng; Ren, Wenhao; Gao, Ling; Cheng, Zheng; Zhang, Linmei; Li, Shaoming; Zhi, Pro Ke-qian

    2016-01-01

    Maxillary defects are usually rehabilitated by a prosthetic obturator. This study aimed to evaluate the functioning of obturators prosthesis in patients with unilateral defects after maxillectomy. Of 49 patients, 28 underwent to maxillectomy as a result of tumor ablative surgery, and acquired unilateral maxillary defects. Evaluation of the function was performed by applying the Obturator Functional Scale (OFS). From a total of 49 patients, 28 were treated as follows: 9 with a conventional retained obturator prosthesis (COP), 11 (39%) with an enhanced retentive obturator prosthesis with stud attachment (POP) and 8 (28%) with an enhanced retentive obturator prosthesis with magnetic attachment (POM). The mean OFS score was 80. Scores on functions of speech, swallowing and chewing reached statistical significances (p<0.05) among these three subgroups. Comparing COP and MOP groups, the scores of OFS in the domains of "Speech-ability to speak in public" and "Swallowing-leakage with liquids" were significantly higher in AOP group. Comparing COP group, the scores of OFS in "Swallowing-leakage with solid" and "Chewing/eating" domains were increased significantly (p<0.05) both in MOP and AOP groups. Obturator prosthesis improves oral function of patients after maxillary defects; the retention of the obturator prosthesis enhanced by the addition of attachments showed more benefits in oral function. Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  14. A new biomechanical hand prosthesis controlled by surface electromyographic signals.

    PubMed

    Andrade, Nei A; Borges, Geovany A; de O Nascimento, Francisco A; Romariz, Alexandre R S; da Rocha, Adson F

    2007-01-01

    This paper describes the development of a low-cost hand prosthesis for use in patients with an amputated hand due to congenital problems or to trauma wound, who possess a part or the forearm endowed with muscular activity. The paper covers the constructive aspects of both mechanical and electronic designs. The prototype is controlled by electromyographic signals measured at the remaining part of the injured limb of the patient. The EMG signals are measured at the surface of the skin, at a point that is close to a working muscle of the amputated arm. The prosthesis allows the patient to hold objects by means of a three finger clamp. The prosthesis presented an excellent performance in preliminary tests with an amputated patient. These tests showed that the prosthesis had a very good performance regarding force and speed.

  15. Rehabilitation with dental prosthesis can increase cerebral regional blood volume.

    PubMed

    Miyamoto, Ikuya; Yoshida, Kazuya; Tsuboi, Yoichi; Iizuka, Tadahiko

    2005-12-01

    Treatment with denture for edentulous people is highly important for maintaining quality of life. However, its effect on the brain is unknown. In this experimental study, we hypothesized that dental prosthesis can recover not only the physical condition of mastication system but also the regional brain activity. We evaluated functional brain imaging of edentulous subjects fixed by dental implant prosthesis with clenching tasks by multi-channel near-infrared optical topography. Results revealed a significantly (P<0.001; paired t-test) increased cerebral regional blood volume during maximum voluntary clenching task by implant-retained prosthesis. There were no statistically significant differences between patients with and without prosthesis in the latency to the maximum regional blood volume after the task. Conclusively, clenching can be effective for increasing cerebral blood volume; accordingly maintenance of normal chewing might prevent the brain from degenerating.

  16. Tracheal replacement in rabbits with a new composite silicone-metallic prosthesis.

    PubMed

    Dodge-Khatami, Ali; Niessen, Hans W M; Koole, Leo H; Klein, Marloes G; van Gulik, Thomas M; de Mol, Bas A J M

    2003-09-01

    A new composite silicone-metallic prosthesis was tested, studying the potential for respiratory epithelial covering over the biocompatible inner lining, in a rabbit survival model. Seven New Zealand White rabbits underwent near-total excision of their trachea and implantation of a sterile prosthesis. After 2 months, they were sacrificed and the prostheses were retrieved. Specimens were fixed and histologically examined for tissue reaction around the prosthesis, at the anastomotic lines, and particularly for the presence or absence of epithelialization of the inner lumen over the biocompatible surface. All rabbits survived the operation. At 2 months, the outer layer of the prosthesis was consistently covered with fibrosis and neutrophils. The inner layer showed necrotic cells and scant re-epithelialization over the biocompatible lining, up to 5 mm beyond the anastomosis, with no evidence of organized respiratory epithelium in the middle sections. The new prosthesis is a viable temporary solution for airway replacement in rabbits. Granulation tissue was not observed at the anastomosis, and re-epithelialization did occur, but failed to achieve full-length luminal covering. The potential for granulation tissue does not yet make this an ideal long-term solution. Improvements in prosthesis design or biocompatibility are required, and need to be re-evaluated before applicability for chronic use.

  17. Design and Characterization of a Quasi-Passive Pneumatic Foot-Ankle Prosthesis.

    PubMed

    Lee, Jeffrey D; Mooney, Luke M; Rouse, Elliott J

    2017-07-01

    The majority of commercially available passive prosthetic feet are not capable of providing joint mechanics that match that of the intact human ankle. Due to their cantilever design, their stiffness characteristics contrast with what has been observed in the biological ankle, namely, an increase in stiffness during the stance phase of walking. In this paper, we introduce the design and control of a pneumatic foot-ankle prosthesis that attempts to provide biomimetic mechanics. The prosthesis is comprised of a pneumatic cylinder in series with a fiberglass leaf spring, and a solenoid valve to control the flow of air between the two sides of the cylinder. The solenoid valve acts as a mechanical clutch, enabling resetting of the ankle's equilibrium position. By adjusting the pressure inside the cylinder, the prosthesis can be customized to provide a range of ankle mechanics. A mechanical testing machine is used to compare the torque-angle curve of the pneumatic prosthesis with a low-profile passive prosthetic foot. Finally, data are presented of one transtibial amputee walking with the prosthesis at 1.2 m/s. The testing shows that the pneumatic prosthesis is capable of providing an appropriate range of motion as well a maximum torque of 94 Nm, while returning approximately 11.5 J of energy.

  18. Cross-cultural adaptation and validation of the VISA-P questionnaire for German-speaking patients with patellar tendinopathy.

    PubMed

    Lohrer, Heinz; Nauck, Tanja

    2011-03-01

    Clinical measurement study. To cross-culturally adapt and validate the Victorian Institute of Sports Assessment Patellar Tendinopathy Questionnaire (VISA-P) for German-speaking patients. Like most questionnaires, the VISA-P was developed for English-speaking patients. There is a need to adapt the scale for German-speaking patients and thereby add to the total body of psychometric evidence relating to this instrument. The VISA-P questionnaire was translated and cross-culturally adapted into German (VISA-P-G) in 6 steps: translation, synthesis, back translation, expert committee review, pretesting, and advisory committee appraisal. The psychometric properties of the VISA-P-G were determined using 23 patients with patellar tendinopathy and 57 active healthy persons (32 sport students and 25 basketball players). Reliability was evaluated by applying the questionnaire twice within a week to all 80 participants. Known group validity was calculated using a 1-way analysis of variance. Additionally, VISA-P-G results were correlated with the Blazina classification system for patellar tendinopathy, using the Spearman rank correlation coefficient. VISA-P-G ratings from the present study groups were further compared with respective data published in the original English, Dutch, and Swedish versions by a 2-sample t test. Internal consistency for the individual items of the questionnaire was determined within the patient group using a Cronbach alpha. Test-retest revealed excellent reliability for the patient and the asymptomatic control group (ICC = 0.88 and 0.87, respectively). Internal consistency for the patients was 0.88. Concurrent validity was almost perfect (ρ = -0.81; P<.001). The VISA-P-G is a reliable and valid questionnaire for the self-assessment of pain, symptoms, and function in German-speaking patients with patellar tendinopathy. Its psychometric properties are comparable with the original English and international adaptations (Swedish, Dutch, and Italian).

  19. Immediate effects of whole body vibration on patellar tendon properties and knee extension torque.

    PubMed

    Rieder, F; Wiesinger, H-P; Kösters, A; Müller, E; Seynnes, O R

    2016-03-01

    Reports about the immediate effects of whole body vibration (WBV) exposure upon torque production capacity are inconsistent. However, the changes in the torque-angle relationship observed by some authors after WBV may hinder the measurement of torque changes at a given angle. Acute changes in tendon mechanical properties do occur after certain types of exercise but this hypothesis has never been tested after a bout of WBV. The purpose of the present study was to investigate whether tendon compliance is altered immediately after WBV, effectively shifting the optimal angle of peak torque towards longer muscle length. Twenty-eight subjects were randomly assigned to either a WBV (n = 14) or a squatting control group (n = 14). Patellar tendon CSA, stiffness and Young's modulus and knee extension torque-angle relationship were measured using ultrasonography and dynamometry 1 day before and directly after the intervention. Tendon CSA was additionally measured 24 h after the intervention to check for possible delayed onset of swelling. The vibration intervention had no effects on patellar tendon CSA, stiffness and Young's modulus or the torque-angle relationship. Peak torque was produced at ~70° knee angle in both groups at pre- and post-test. Additionally, the knee extension torque globally remained unaffected with the exception of a small (-6%) reduction in isometric torque at a joint angle of 60°. The present results indicate that a single bout of vibration exposure does not substantially alter patellar tendon properties or the torque-angle relationship of knee extensors.

  20. Atlanto-occipital dislocation: Case report and discussion.

    PubMed

    Asfaw, Tehetena; Chow, Bernard; Frederiksen, Ryan A

    2011-01-01

    Traumatic atlanto-occipital dislocation is an uncommon injury that frequently results in either a fatal outcome or severe neurologic deficit. This diagnosis must be considered for any patients who may have had cervical spine damage after high trauma, even in the absence of neurologic signs, as there have been reports of cases without neurologic impairment. In addition to radiographic examination, including lateral cervical radiographs, supplemental imaging with CT or MRI may be required to confirm diagnosis in equivocal cases, and to help in evaluation of bone and nervous structures. Moreover, these modalities allow measurement of the magnitude of dislocation and aid in classification of type of dislocation, which helps guide management. A systematic approach to evaluating the cranio-cervical relationship is critical to identifying atlanto-occipital dislocation. This case report presents and discusses imaging findings that will assist in the diagnosis of atlanto-occipital dislocation.

  1. Kneecap dislocation

    MedlinePlus

    ... dislocates to the outside of the knee Knee pain and tenderness Knee swelling "Sloppy" kneecap -- you can move the kneecap ... knee and you notice: Increased instability in your knee Pain or swelling return after they went away Your ...

  2. Hydrogenated vacancies lock dislocations in aluminium

    PubMed Central

    Xie, Degang; Li, Suzhi; Li, Meng; Wang, Zhangjie; Gumbsch, Peter; Sun, Jun; Ma, Evan; Li, Ju; Shan, Zhiwei

    2016-01-01

    Due to its high diffusivity, hydrogen is often considered a weak inhibitor or even a promoter of dislocation movements in metals and alloys. By quantitative mechanical tests in an environmental transmission electron microscope, here we demonstrate that after exposing aluminium to hydrogen, mobile dislocations can lose mobility, with activating stress more than doubled. On degassing, the locked dislocations can be reactivated under cyclic loading to move in a stick-slip manner. However, relocking the dislocations thereafter requires a surprisingly long waiting time of ∼103 s, much longer than that expected from hydrogen interstitial diffusion. Both the observed slow relocking and strong locking strength can be attributed to superabundant hydrogenated vacancies, verified by our atomistic calculations. Vacancies therefore could be a key plastic flow localization agent as well as damage agent in hydrogen environment. PMID:27808099

  3. Hydrogenated vacancies lock dislocations in aluminium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xie, Degang; Li, Suzhi; Li, Meng

    Due to its high diffusivity, hydrogen is often considered a weak inhibitor or even a promoter of dislocation movements in metals and alloys. By quantitative mechanical tests in an environmental transmission electron microscope, here we demonstrate that after exposing aluminium to hydrogen, mobile dislocations can lose mobility, with activating stress more than doubled. On degassing, the locked dislocations can be reactivated under cyclic loading to move in a stick-slip manner. However, relocking the dislocations thereafter requires a surprisingly long waiting time of ~10 3 s, much longer than that expected from hydrogen interstitial diffusion. Both the observed slow relocking andmore » strong locking strength can be attributed to superabundant hydrogenated vacancies, verified by our atomistic calculations. In conclusion, vacancies therefore could be a key plastic flow localization agent as well as damage agent in hydrogen environment.« less

  4. Hydrogenated vacancies lock dislocations in aluminium

    DOE PAGES

    Xie, Degang; Li, Suzhi; Li, Meng; ...

    2016-11-03

    Due to its high diffusivity, hydrogen is often considered a weak inhibitor or even a promoter of dislocation movements in metals and alloys. By quantitative mechanical tests in an environmental transmission electron microscope, here we demonstrate that after exposing aluminium to hydrogen, mobile dislocations can lose mobility, with activating stress more than doubled. On degassing, the locked dislocations can be reactivated under cyclic loading to move in a stick-slip manner. However, relocking the dislocations thereafter requires a surprisingly long waiting time of ~10 3 s, much longer than that expected from hydrogen interstitial diffusion. Both the observed slow relocking andmore » strong locking strength can be attributed to superabundant hydrogenated vacancies, verified by our atomistic calculations. In conclusion, vacancies therefore could be a key plastic flow localization agent as well as damage agent in hydrogen environment.« less

  5. Peierls-Nabarro modeling of dislocations in UO2

    NASA Astrophysics Data System (ADS)

    Skelton, Richard; Walker, Andrew M.

    2017-11-01

    Under conditions of high stress or low temperature, glide of dislocations plays an important role in the deformation of UO2. In this paper, the Peierls-Nabarro model is used to calculate the core widths and Peierls stresses of ½<110> edge and screw dislocations gliding on {100}, {110}, and {111}. The energy of the inelastic displacement field in the dislocation core is parameterized using generalized stacking fault energies, which are calculated atomistically using interatomic potentials. We use seven different interatomic potential models, representing the variety of different models available for UO2. The different models broadly agree on the relative order of the strengths of the different slip systems, with the 1/2<110>{100} edge dislocation predicted to be the weakest slip system and 1/2<110>{110} the strongest. However, the calculated Peierls stresses depend strongly on the interatomic potential used, with values ranging between 2.7 and 12.9 GPa for glide of 1/2<110>{100} edge dislocations, 16.4-32.3 GPa for 1/2<110>{110} edge dislocations, and 6.8-13.6 GPa for 1/2<110>{111} edge dislocations. The glide of 1/2<110> screw dislocations in UO2 is also found to depend on the interatomic potential used, with some models predicting similar Peierls stresses for glide on {100} and {111}, while others predict a unique easy glide direction. Comparison with previous fully atomistic calculations show that the Peierls-Nabarro model can accurately predict dislocation properties in UO2.

  6. Surface dislocation nucleation controlled deformation of Au nanowires

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roos, B.; Kapelle, B.; Volkert, C. A., E-mail: volkert@ump.gwdg.de

    2014-11-17

    We investigate deformation in high quality Au nanowires under both tension and bending using in-situ transmission electron microscopy. Defect evolution is investigated during: (1) tensile deformation of 〈110〉 oriented, initially defect-free, single crystal nanowires with cross-sectional widths between 30 and 300 nm, (2) bending deformation of the same wires, and (3) tensile deformation of wires containing coherent twin boundaries along their lengths. We observe the formation of twins and stacking faults in the single crystal wires under tension, and storage of full dislocations after bending of single crystal wires and after tension of twinned wires. The stress state dependence of themore » deformation morphology and the formation of stacking faults and twins are not features of bulk Au, where deformation is controlled by dislocation interactions. Instead, we attribute the deformation morphologies to the surface nucleation of either leading or trailing partial dislocations, depending on the Schmid factors, which move through and exit the wires producing stacking faults or full dislocation slip. The presence of obstacles such as neutral planes or twin boundaries hinder the egress of the freshly nucleated dislocations and allow trailing and leading partial dislocations to combine and to be stored as full dislocations in the wires. We infer that the twins and stacking faults often observed in nanoscale Au specimens are not a direct size effect but the result of a size and obstacle dependent transition from dislocation interaction controlled to dislocation nucleation controlled deformation.« less

  7. Simplified technique for orbital prosthesis fabrication: a clinical report.

    PubMed

    Veerareddy, Chandrika; Nair, K Chandrasekharan; Reddy, G Ramaswamy

    2012-10-01

    Loss of orbital content can cause functional impairment, disfigurement of the face, and psychological distress. Rehabilitation of an orbital defect is a complex task, and if reconstruction by plastic surgery is not possible or not desired by the patient, the defect can be rehabilitated by an orbital prosthesis. The prosthetic rehabilitation in such cases depends on the precisely retained, user-friendly removable maxillofacial prosthesis. Many times, making an impression of the orbital area with an accurate record of surface details can be a difficult procedure. The critical areas are making a facial moulage, mold preparation, and attaching the retention device, particularly when eyeglass frames are used. This case focuses on these hindrance factors. A simple basket was used for the impression tray to obtain the facial moulage. A putty mold was used, and attachment of the prosthesis to a retention device was accomplished with positional distance. This method proves to be an economical and simple way of making an orbital prosthesis. © 2012 by the American College of Prosthodontists.

  8. Dynamics of threading dislocations in porous heteroepitaxial GaN films

    NASA Astrophysics Data System (ADS)

    Gutkin, M. Yu.; Rzhavtsev, E. A.

    2017-12-01

    Behavior of threading dislocations in porous heteroepitaxial gallium nitride (GaN) films has been studied using computer simulation by the two-dimensional discrete dislocation dynamics approach. A computational scheme, where pores are modeled as cross sections of cylindrical cavities, elastically interacting with unidirectional parallel edge dislocations, which imitate threading dislocations, is used. Time dependences of coordinates and velocities of each dislocation from dislocation ensembles under investigation are obtained. Visualization of current structure of dislocation ensemble is performed in the form of a location map of dislocations at any time. It has been shown that the density of appearing dislocation structures significantly depends on the ratio of area of a pore cross section to area of the simulation region. In particular, increasing the portion of pores surface on the layer surface up to 2% should lead to about a 1.5-times decrease of the final density of threading dislocations, and increase of this portion up to 15% should lead to approximately a 4.5-times decrease of it.

  9. Fifteen years experience of penile prosthesis insertion.

    PubMed

    Burns-Cox, N; Burston, A; Gingell, J C

    1997-12-01

    To review the outcome and patient satisfaction of penile prosthesis insertion over a 15 y period. We reviewed the notes of 172 patients who underwent penile prosthesis insertion between January 1980 and May 1995. From the notes information was determined on age of the patient, type of prosthesis, surgical approach and length of stay. Also noted were risk factors for erectile dysfunction and the aetiology. Twenty patients were known to have died or moved away. To assess the impact the operation had on quality of life, 152 questionnaires were sent of which 103 were returned (67%). The questionnaire gained information about sexual activity, before and after the operation and the overall satisfaction of the patient and his partner and whether they felt the operation was a success. Overall 149 patients were known to have had malleable prostheses inserted and 23 had inflatables. The commonest organic groups were vascular disease, diabetes and Peyronies disease. Fifteen patients had two procedures. Four patients required revision of the prosthesis due to erosion, and there was one death due to pulmonary embolism. One hundred and three completed questionnaires have been returned to date the median time since operation was 4 y, the range being six months to 16 y and 78% thought the operation was a success. The insertion of malleable prostheses is associated with low complication rates, good patient satisfaction and improved quality of life for the couple. Concealment was not a major problem.

  10. Characterising the proximal patellar tendon attachment and its relationship to skeletal maturity in adolescent ballet dancers

    PubMed Central

    Rudavsky, Aliza; Cook, Jillianne; Magnusson, Stig Peter; Kjaer, Michael; Docking, Sean

    2017-01-01

    Summary Background It is unknown how and when the proximal attachment of the patellar tendon matures; puberty may be key in ensuring normal tendon formation. The aim of this study was to investigate the features of the proximal patellar tendon attachment at different stages of skeletal maturity, to help gain an understanding of how and when the tendon attachment matures. Methods Sixty adolescent elite ballet students (ages 11–18) and eight mature adults participated. Peak height velocity (PHV) estimated skeletal maturity. Ultrasound tissue characterisation (UTC) scan was taken of the left knee and analysed for stability of echopattern. An image-based grading scale for greyscale ultrasound was developed to describe the tendon appearance. Anterior-posterior thickness was measured at the inferior pole of the patella, 1 and 2 centimetres distally. Outcomes were compared with skeletal maturity. Results Mid-portion patellar tendon thickness increased with skeletal maturity (p=0.001 at 1 cm and p=0.007 at 2 cm). There was more variance in structural appearance (greyscale classification and UTC echopattern) in pre and peri-PHV participants. Tendon attachment one-year post PHV appeared similar to mature tendons. Conclusions Early adolescence was associated with highly variable tendon appearance, whereas the tendon appeared mature after PHV. Adolescence may be a critical time for the formation of normal tendon attachment. Level of evidence IIb individual cohort study. PMID:29264342

  11. Hydrogen diffusion in the elastic fields of dislocations in iron

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sivak, A. B., E-mail: Sivak-AB@nrcki.ru; Sivak, P. A.; Romanov, V. A.

    2016-12-15

    The effect of dislocation stress fields on the sink efficiency thereof is studied for hydrogen interstitial atoms at temperatures of 293 and 600 K and at a dislocation density of 3 × 10{sup 14} m{sup –2} in bcc iron crystal. Rectilinear full screw and edge dislocations in basic slip systems 〈111〉(110), 〈111〉(112), 〈100〉(100), and 〈100〉(110) are considered. Diffusion of defects is simulated by means of the object kinetic Monte Carlo method. The energy of interaction between defects and dislocations is calculated using the anisotropic theory of elasticity. The elastic fields of dislocations result in a less than 25% change ofmore » the sink efficiency as compared to the noninteracting linear sink efficiency at a room temperature. The elastic fields of edge dislocations increase the dislocation sink efficiency, whereas the elastic fields of screw dislocations either decrease this parameter (in the case of dislocations with the Burgers vector being 1/2〈111〉) or do not affect it (in the case of dislocations with the Burgers vector being 〈100〉). At temperatures above 600 K, the dislocations affect the behavior of hydrogen in bcc iron mainly owing to a high binding energy between the hydrogen atom and dislocation cores.« less

  12. Custom-made silicone hand prosthesis: A case study.

    PubMed

    Nayak, S; Lenka, P K; Equebal, A; Biswas, A

    2016-09-01

    Up to now, a cosmetic glove was the most common method for managing transmetacarpal (TMC) and carpometacarpal (CMC) amputations, but it is devoid of markings and body color. At this amputation level, it is very difficult to fit a functional prosthesis because of the short available length, unsightly shape, grafted skin, contracture and lack of functional prosthetic options. A 30-year-old male came to our clinic with amputation at the 1st to 4th carpometacarpal level and a 5th metacarpal that was projected laterally and fused with the carpal bone. The stump had grafted skin, redness, and an unhealed suture line. He complained of pain projected over the metacarpal and suture area. The clinical team members decided to fabricate a custom-made silicone hand prosthesis to accommodate the stump, protect the grafted skin, improve the hand's appearance and provide some passive function. The custom silicone hand prosthesis was fabricated with modified flexible wires to provide passive interphalangeal movement. Basic training, care and maintenance instructions for the prosthesis were given to the patient. The silicone hand prosthesis was able to restore the appearance of the lost digits and provide some passive function. His pain (VAS score) was reduced. Improvement in activities of daily living was found in the DASH questionnaire and Jebsen-Taylor Hand Function test. A silicone glove is a good option for more distal amputations, as it can accommodate any deformity, protect the skin, enhance the appearance and provide functional assistance. This case study provides a simple method to get passively movable fingers after proximal hand amputation. Copyright © 2016. Published by Elsevier Masson SAS.

  13. "Bail out" procedures for malpositioning of aortic valve prosthesis (CoreValve).

    PubMed

    Vavouranakis, Manolis; Vrachatis, Dimitrios A; Toutouzas, Konstantinos P; Chrysohoou, Christina; Stefanadis, Christodoulos

    2010-11-05

    Two techniques for correcting malpositioning occurring during percutaneous aortic valve replacement (PAVR) with the CoreValve ReValving™ System are described in this article. The "Removing and Reinserting Technique" was used in 2 patients, in whom the prosthesis was positioned too high. The "Snare Technique" was used in 1 patient, in whom the prosthesis was implanted too low. In all patients the aortic valve prosthesis was successfully re-implanted. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  14. [Lysis of the incus long process and incudostapedial rebridging ossiculoplasty: comparative study of titanium-gold angle prosthesis Plester-type versus Martin Incudo prosthesis hydroxylapatite].

    PubMed

    Faye, M B; Martin, C; Schmerber, S

    2013-01-01

    We report two surgical techniques devised to restore a disrupted incudostapedial joint. Thirty patients underwent rebridging of distal portion of incus long process in the ENT Department of University of Grenoble and Saint-Etienne, between October 1998 and September 2002. Two types of ossicular prostheses were used: A titanium-gold angle prosthesis according to Plester Winkel Kurz (n = 16 patients), and a hydroxylapatite prosthesis as Martin Incudo Prosthesis (n = 14 patients). The average hearing gain in short term is of 8.30 dB for the Martin-Incudo group. It is of 5.23 dB in the Winkel group. Seven and three cases of failures (Residual Rinne > 20 dB) were noticed respectively in the groups Martin-Incudo and Winkel. Seven and four cases of labyrinthisation were observed respectively in the groups Martin-Incudo and Winkel. The average hearing gain in long term is 3.43 dB in the Martin-Incudo group; and 2.85 dB among patients with Winkel Kurz prosthesis. Average residual Rinne is higher than 20 dB in the Winkel group. The hearing gain is not statistically significant between the two groups (p > 0.05). The titanium partial prosthesis did not give good functional results. In the case of a limited lysis (< 2 mm) of the distal portion of incus, we use the cement or cartilage interposition. When ossicular chain cannot be preserved entirely, we privilege incus transposition or a titanium PORP. The Martin-Incudo prosthesis seems interesting in the event of lysis of 2 mm of the long process of incus, nevertheless engineering changes are necessary in order to make rigid the incudostapedial joint.

  15. Management of an Anophthalmic Patient by the Fabrication of Custom Made Ocular Prosthesis

    PubMed Central

    SINGH, Meenakshi; NAYAK, Meghanand; SOLANKI, Jitender; GUPTA, Sarika; SINGH, Anjali

    2015-01-01

    The loss or disfigurement of a body parts specially that pertaining to the face has a deep psychological and social impact on the patient. After enucleation, evisceration or exteneration of the eye, the aim of an ocular prosthesis should be to restore the natural appearance, install confidence and a sense social acceptability in the patient. Custom made prosthesis has several advantages over the stock eye prosthesis. This article illustrates rehabilitation of the enucleated right eye of a patient with a custom made ocular prosthesis. PMID:26715901

  16. Rehabilitation of a missing ear with an implant retained auricular prosthesis

    PubMed Central

    Guttal, Satyabodh Sheshraj; Shanbhag, Shruti; Kulkarni, Sudhindra S.; Thakur, Srinath L.

    2015-01-01

    Burns can leave a patient with a severely debilitating disability even after treatment. The objectives of burn rehabilitation are to minimize the adverse effects caused by the injury while rehabilitating the patient's physical and psychological well-being, maximizing social integration. Long-term success of maxillofacial prostheses mainly depends on the retention. Extra oral implant retained prostheses have proved to be a predictable treatment option for maxillofacial rehabilitation. Replacement of a severely deformed external ear with burned tissues may be satisfactorily accomplished by a cosmetic prosthesis anchored by implants integrated in the skull. The use of such implants is now a well-recognized method for creating a stable result in maxillofacial rehabilitation. This case report describes a safe, simple and economical method for the rehabilitation of a patient with missing right auricle using an implant supported silicone prosthesis. The implant was placed in the mastoid region of the temporal bone. Reconstruction of the ear was done with auricular silicone prosthesis, retained using magnets incorporated in an autopolymerizing resin shim to decrease the weight of the prosthesis on a single implant. This method eliminates the need of tedious laboratory procedures and exact casting and fitting requirements of a metal substructure while minimizing the overall weight and cost of the prosthesis while maintaining adequate support, esthetics and retention of the prosthesis. PMID:26929490

  17. Rehabilitation of orbital cavity after orbital exenteration using polymethyl methacrylate orbital prosthesis.

    PubMed

    Jain, Sumeet; Jain, Parul

    2016-01-01

    Squamous cell carcinoma of the eyelid is the second most common malignant neoplasm of the eye with the incidence of 0.09 and 2.42 cases/100 000 people. Orbital invasion is a rare complication but, if recognized early, can be treated effectively with exenteration. Although with advancements in technology such as computer-aided design and computer-aided manufacturing, material science, and retentive methods like implants, orbital prosthesis with stock ocular prosthesis made of methyl methacrylate retained by anatomic undercuts is quiet effective and should not be overlooked and forgotten. This clinical report describes prosthetic rehabilitation of two male patients with polymethyl methacrylate resin orbital prosthesis after orbital exenteration, for squamous cell carcinoma of the upper eyelid. The orbital prosthesis was sufficiently retained by hard and soft tissue undercuts without any complications. The patients using the prosthesis are quite satisfied with the cosmetic results and felt comfortable attending the social events.

  18. Dislocation structure produced by an ultrashort shock pulse

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matsuda, Tomoki, E-mail: t-matsu@mapse.eng.osaka-u.ac.jp; Hirose, Akio; Sano, Tomokazu

    We found an ultrashort shock pulse driven by a femtosecond laser pulse on iron generates a different dislocation structure than the shock process which is on the nanosecond timescale. The ultrashort shock pulse produces a highly dense dislocation structure that varies by depth. According to transmission electron microscopy, dislocations away from the surface produce microbands via a network structure similar to a long shock process, but unlike a long shock process dislocations near the surface have limited intersections. Considering the dislocation motion during the shock process, the structure near the surface is attributed to the ultrashort shock duration. This approachmore » using an ultrashort shock pulse will lead to understanding the whole process off shock deformation by clarifying the early stage.« less

  19. Dislocation filtering in GaN nanostructures.

    PubMed

    Colby, Robert; Liang, Zhiwen; Wildeson, Isaac H; Ewoldt, David A; Sands, Timothy D; García, R Edwin; Stach, Eric A

    2010-05-12

    Dislocation filtering in GaN by selective area growth through a nanoporous template is examined both by transmission electron microscopy and numerical modeling. These nanorods grow epitaxially from the (0001)-oriented GaN underlayer through the approximately 100 nm thick template and naturally terminate with hexagonal pyramid-shaped caps. It is demonstrated that for a certain window of geometric parameters a threading dislocation growing within a GaN nanorod is likely to be excluded by the strong image forces of the nearby free surfaces. Approximately 3000 nanorods were examined in cross-section, including growth through 50 and 80 nm diameter pores. The very few threading dislocations not filtered by the template turn toward a free surface within the nanorod, exiting less than 50 nm past the base of the template. The potential active region for light-emitting diode devices based on these nanorods would have been entirely free of threading dislocations for all samples examined. A greater than 2 orders of magnitude reduction in threading dislocation density can be surmised from a data set of this size. A finite element-based implementation of the eigenstrain model was employed to corroborate the experimentally observed data and examine a larger range of potential nanorod geometries, providing a simple map of the different regimes of dislocation filtering for this class of GaN nanorods. These results indicate that nanostructured semiconductor materials are effective at eliminating deleterious extended defects, as necessary to enhance the optoelectronic performance and device lifetimes compared to conventional planar heterostructures.

  20. Influence of age on clinical outcomes of three-dimensional transfer of the tibial tuberosity for patellar instability with patella alta.

    PubMed

    Otsuki, Shuhei; Nakajima, Mikio; Fujiwara, Kenta; Okamoto, Yoshinori; Iida, Go; Murakami, Tomohiko; Neo, Masashi

    2017-08-01

    To evaluate the clinical outcomes of three-dimensional (3D) transfer of the tibial tuberosity for patellar instability with patella alta, with a focus on the influence of age at initial surgery. Three-dimensional surgery was performed on 28 knees with a mean follow-up of 46 months. Patients were separated into three groups based on the age at initial surgery: group A, 10 knees and an average age of 16.3 ± 1.8 (14-19) years; group B, 10 knees and an average age of 22.1 ± 2.5 (20-28) years; and group C, eight knees and an average age of 44.0 ± 2.2 (40-46) years. Patellofemoral geometry improvement focused on patella alta by determining the Insall-Salvati ratio and Caton-Deschamps index, rotational malalignment by measuring the tibial tubercle-trochlear groove (TT-TG) distance, and lateral patellar subluxation by measuring the patellar tilt. Clinical outcomes were evaluated by the Lysholm and Kujala scores, which were compared before and after surgery. Cartilage degeneration was evaluated by the International Cartilage Repair Society grading system at initial arthroscopy. The patellar height, TT-TG, and patellar tilt significantly improved in all groups postoperatively (p < 0.05). The Lysholm and Kujala scores also significantly improved postoperatively; however, both scores were lower in group C than in the other groups (p < 0.05). Particularly, pain scores were more severe in group C than in the other groups, and the severity of cartilage degeneration correlated with the pain scores (p < 0.05). Cartilage damage differed significantly between the groups at initial arthroscopy; particularly, group C included grades III and IV cartilage degeneration (p < 0.05). Age at initial surgery may be the predicting factor for poor clinical outcomes of 3D transfer surgery. The clinical outcome may depend on the age at surgery, which correlated with cartilage damage; thus, surgeons should be given this information when patients are considered undergoing patella

  1. Dislocation evolution in 316 L stainless steel during multiaxial ratchetting deformation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dong Yawei; Kang Guozheng, E-mail: guozhengkang@yahoo.com.cn; Liu Yujie

    2012-03-15

    Dislocation patterns and their evolutions in 316 L stainless steel during the multiaxial ratchetting deformation were observed by transmission electron microscopy (TEM). The microscopic observations indicate that the dislocation evolution presented during the multiaxial ratchetting with four kinds of multiaxial loading paths is similar to that in the uniaxial case [G. Z. Kang et al., Mater Sci Eng A 527 (2010) 5952]. That is, dislocation networks and dislocation tangles are formed quickly by the multiple-slip and cross-slip of dislocation activated by applied multiaxial stress; and then polarized patterns such as dislocation walls and elongated incipient dislocation cells are formed atmore » the last stage of multiaxial ratchetting. The dislocation patterns evolve more quickly from the modes at low dislocation density to the ones at high density during the multiaxial ratchetting than that in the uniaxial case, and some traces of multiple-slip are observed in the multiaxial ones. The dislocation evolution during the multiaxial ratchetting deformation is summarized by comparing the observed dislocation patterns with those presented in the multiaxial strain-controlled and symmetrical stress-controlled cyclic tests. The multiaxial ratchetting of 316 L stainless steel can be microscopically and qualitatively explained by the observed evolution of dislocation patterns. - Highlights: Black-Right-Pointing-Pointer Dislocation patterns change from lines and nets to tangles, walls and cells. Black-Right-Pointing-Pointer Dislocation patterns evolve quicker in the multiaxial case. Black-Right-Pointing-Pointer Aligned dislocation arrays and some traces of multiple slips are observed. Black-Right-Pointing-Pointer Heterogeneous dislocation patterns result in the multiaxial ratchetting.« less

  2. Facial recognition using enhanced pixelized image for simulated visual prosthesis.

    PubMed

    Li, Ruonan; Zhhang, Xudong; Zhang, Hui; Hu, Guanshu

    2005-01-01

    A simulated face recognition experiment using enhanced pixelized images is designed and performed for the artificial visual prosthesis. The results of the simulation reveal new characteristics of visual performance in an enhanced pixelization condition, and then new suggestions on the future design of visual prosthesis are provided.

  3. Implant and prosthesis movement after enucleation: a randomized controlled trial.

    PubMed

    Shome, Debraj; Honavar, Santosh G; Raizada, Kuldeep; Raizada, Deepa

    2010-08-01

    To evaluate implant and prosthesis movement after myoconjunctival enucleation and subsequent polymethyl methacrylate (PMMA) implantation, compared with the traditional enucleation with muscle imbrication using a PMMA implant and with enucleation accompanied by porous polyethylene implantation. Randomized, controlled, observer-masked, interventional study. One hundred fifty patients, equally and randomly allocated to the 3 groups. Group 1 consisted of patients in whom a PMMA implant was used after enucleation with muscle imbrication (traditional PMMA group). Group 2 consisted of patients in whom a PMMA implant was used after enucleation with a myoconjunctival technique (myoconjunctival PMMA group). Group 3 consisted of patients in whom a porous polyethylene implant was used after enucleation by the scleral cap technique (porous polyethylene group). Fifty patients were included in each group. Patients were allocated to 1 of the 3 groups using stratified randomization. Informed consent was obtained. Acrylic prostheses custom made by a trained ocularist were fitted 6 weeks after surgery in all patients. A masked observer measured implant and prosthesis movement 6 weeks after surgery using a slit-lamp device with real-time video and still photographic documentation. Analysis of implant and prosthesis movement was carried out using the Mann-Whitney U test, and a P value of < or =0.03 was considered significant. Complications including implant displacement and exposure also were noted. Implant and prosthesis movement. Myoconjunctival PMMA implant movement was better than the traditional PMMA implant (P = 0.001), but was similar to that of the porous polyethylene implant. Prosthesis movement with the myoconjunctival PMMA implant was better than that of either the traditional PMMA (P = 0.001) or porous polyethylene (P = 0.002) implants. Myoconjunctival enucleation technique with a PMMA implant provides statistically and clinically significantly better implant and prosthesis

  4. Research, design & development project Myoelectric Prosthesis of Upper Limb

    NASA Astrophysics Data System (ADS)

    Galiano, L.; Montaner, E.; Flecha, A.

    2007-11-01

    A Research Design and Development Project was developed of a myoelectric prosthesis for a pediatric patient presenting congenital amputation of the left forearm below the elbow. A multidisciplinary work-team was formed for this goal, in order to solve the several (/various) aspects regarding this project (mechanical, ergonomics, electronics, physical). The prosthesis as an electromechanical device was divided in several blocks, trying to achieve a focused development for each stage, acording to requisites. A mechanical prototype of the prothesis was designed and built along with the circuitry needed for EMG aquisition, control logic and drivers. Having acomplished the previuos stages, the project is now dealing with the definitions of the interface between the prosthesis and the patient, with promising perspectives.

  5. Collective behaviour of dislocations in a finite medium

    NASA Astrophysics Data System (ADS)

    Kooiman, M.; Hütter, M.; Geers, M. G. D.

    2014-04-01

    We derive the grand-canonical partition function of straight and parallel dislocation lines without making a priori assumptions on the temperature regime. Such a systematic derivation for dislocations has, to the best of our knowledge, not been carried out before, and several conflicting assumptions on the free energy of dislocations have been made in the literature. Dislocations have gained interest as they are the carriers of plastic deformation in crystalline materials and solid polymers, and they constitute a prototype system for two-dimensional Coulomb particles. Our microscopic starting level is the description of dislocations as used in the discrete dislocation dynamics (DDD) framework. The macroscopic level of interest is characterized by the temperature, the boundary deformation and the dislocation density profile. By integrating over state space, we obtain a field theoretic partition function, which is a functional integral of the Boltzmann weight over an auxiliary field. The Hamiltonian consists of a term quadratic in the field and an exponential of this field. The partition function is strongly non-local, and reduces in special cases to the sine-Gordon model. Moreover, we determine implicit expressions for the response functions and the dominant scaling regime for metals, namely the low-temperature regime.

  6. Singularity-free dislocation dynamics with strain gradient elasticity

    NASA Astrophysics Data System (ADS)

    Po, Giacomo; Lazar, Markus; Seif, Dariush; Ghoniem, Nasr

    2014-08-01

    The singular nature of the elastic fields produced by dislocations presents conceptual challenges and computational difficulties in the implementation of discrete dislocation-based models of plasticity. In the context of classical elasticity, attempts to regularize the elastic fields of discrete dislocations encounter intrinsic difficulties. On the other hand, in gradient elasticity, the issue of singularity can be removed at the outset and smooth elastic fields of dislocations are available. In this work we consider theoretical and numerical aspects of the non-singular theory of discrete dislocation loops in gradient elasticity of Helmholtz type, with interest in its applications to three dimensional dislocation dynamics (DD) simulations. The gradient solution is developed and compared to its singular and non-singular counterparts in classical elasticity using the unified framework of eigenstrain theory. The fundamental equations of curved dislocation theory are given as non-singular line integrals suitable for numerical implementation using fast one-dimensional quadrature. These include expressions for the interaction energy between two dislocation loops and the line integral form of the generalized solid angle associated with dislocations having a spread core. The single characteristic length scale of Helmholtz elasticity is determined from independent molecular statics (MS) calculations. The gradient solution is implemented numerically within our variational formulation of DD, with several examples illustrating the viability of the non-singular solution. The displacement field around a dislocation loop is shown to be smooth, and the loop self-energy non-divergent, as expected from atomic configurations of crystalline materials. The loop nucleation energy barrier and its dependence on the applied shear stress are computed and shown to be in good agreement with atomistic calculations. DD simulations of Lome-Cottrell junctions in Al show that the strength of the

  7. [New varieties of lateral metatarsophalangeal dislocations of the great toe].

    PubMed

    Bousselmame, N; Rachid, K; Lazrak, K; Galuia, F; Taobane, H; Moulay, I

    2001-04-01

    We report seven cases of traumatic dislocation of the great toe, detailing the anatomy, the mechanism of injury and the radiographic diagnosis. We propose an additional classification based on three hereto unreported cases. Between october 1994 and october 1997, we treated seven patients with traumatic dislocation of the first metatarso-phalangeal joint of the great toe. There were six men and one woman, mean age 35 years (range 24 - 44 years). Dislocation was caused by motor vehicle accidents in four cases and by falls in three. Diagnosis was made on anteroposterior, lateral and medial oblique radiographs. According to Jahss' classification, there was one type I and three type IIB dislocations. There was also one open lateral dislocation and two dorsomedial dislocations. Only these dorsomedial dislocations required open reduction, done via a dorsal approach. Mean follow-up was 17.5 months (range 9 - 24 months) in six cases. One patient was lost to follow-up. The outcome was good in six cases and poor in one (dorsomedial dislocation). Dislocation of the first metatarso-phalangeal joint of the great toe is an uncommon injury. In 1980, Jahss reported two cases and reviewed three others described in the literature. He proposed three types of dislocation based on the feasibility of closed reduction (type I, II and IIB). In 1991, Copeland and Kanat reported a unique case in which there was an association of IIA and IIB lesions. They proposed an addition to the classification (type IIC). In 1994, Garcia Mata et al. reported another case which had not been described by Jahss and proposed another addition. All dislocations reported to date have been sagittal dislocations. Pathological alteration of the collateral ligaments has not been previously reported. In our experience, we have seen one case of open lateral dislocation due, at surgical exploration, to medial ligament rupture and two cases of dorsomedial dislocation due, at surgical exploration, to lateral ligament

  8. Modeling of dislocation dynamics in germanium Czochralski growth

    NASA Astrophysics Data System (ADS)

    Artemyev, V. V.; Smirnov, A. D.; Kalaev, V. V.; Mamedov, V. M.; Sidko, A. P.; Podkopaev, O. I.; Kravtsova, E. D.; Shimansky, A. F.

    2017-06-01

    Obtaining very high-purity germanium crystals with low dislocation density is a practically difficult problem, which requires knowledge and experience in growth processes. Dislocation density is one of the most important parameters defining the quality of germanium crystal. In this paper, we have performed experimental study of dislocation density during 4-in. germanium crystal growth using the Czochralski method and comprehensive unsteady modeling of the same crystal growth processes, taking into account global heat transfer, melt flow and melt/crystal interface shape evolution. Thermal stresses in the crystal and their relaxation with generation of dislocations within the Alexander-Haasen model have been calculated simultaneously with crystallization dynamics. Comparison to experimental data showed reasonable agreement for the temperature, interface shape and dislocation density in the crystal between calculation and experiment.

  9. Editorial Commentary: Which Came First, the Patella or the Trochlea? Morphological Relationships in Patients With Patellar Instability.

    PubMed

    Tanaka, Miho J

    2018-06-01

    Trochlear dysplasia and patella alta are known risk factors for patellar instability, yet the relation between the two has not been well understood. Morphologic abnormalities such as trochlear dysplasia and patella alta are known to alter patellofemoral kinematics, whereas altered contact pressures, in turn, have been associated with the development of trochlear dysplasia. As our current treatments aim to correct these deformities through increasingly complex procedures such as trochleoplasty and tuberosity distalization, we should consider this relation and the potential for changing the course of developing such morphologic abnormalities earlier in life. Further studies on the developmental cause of this disorder may help guide future treatments in the management of patellar instability. Copyright © 2018 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  10. [Treatment of septic olecranon and patellar bursitis by excision and vacuum-assisted closure therapy].

    PubMed

    Walter, G; Kemmerer, M; Hoffmann, R

    2013-08-01

    Treatment of septic olecranon and patellar bursitis differs considerably and is currently under discussion. We therefore performed a retrospective study of our patients with septic bursitis in the past 5 years. Between March 2007 and February 2012 we treated 79 patients with septic olecranon (n = 43) and patellar (n = 36) bursitis surgically: 61-males, 18 females, age 51 (range: 11-91) years. Four patients had not been treated before, 25 had suffered recurrences after 1-10 previous procedures, and 9 patients had not improved after conservative therapy. 34 patients presented with traumatic rupture or fistula of their bursae. In all cases we performed a radical bursectomy and vacuum-assisted therapy for 4 to 5 days. In addition, patients received systemic antibiotics. We phoned all patients and were successful in 57 cases (72 %). We questioned these patients for range of movement, limitations at work, pain, sensibility disorder, satisfaction with the result and further surgical procedures. In all cases we took tissue specimens for cultures, in 48 preparations histological examination was performed. Microbiological and histological results are discussed in detail. 40 patients were free of complaints, 15 complained of mild pain, 54 of 57 had unlimited range of motion. Minor discomforts at desk work were reported by 5 of 43 patients, 12 out of 36 patient reported discomfort when performing on their knees. There was no recurrence in the period of investigation. We recommend our treatment concept for septic olecranon and patellar bursitis because patient satisfaction is high and recurrences are reliably avoided. The soft tissue is spared, so that plastic covering procedures are seldom necessary. Georg Thieme Verlag KG Stuttgart · New York.

  11. [Rehabilitation by hollow obturator prosthesis immediately after total maxillectomy for malignant tumor].

    PubMed

    Li, Xiao-ye; Yan, Ai-hui; Hao, Shuai; Li, Wei; Jiang, Xue-jun; Lu, Li; Qin, Xing-jun; Yan, Hai-xin

    2011-05-01

    The feasibility and clinical effects of hollow obturator prosthesis for the repair of maxillofacial defect immediately after maxillectomy for cancer were assessed. Thirteen patients with T3-4aN0M0 maxillary neoplasm were treated by the prostheses immediately after maxillectomy. According to the 3D-CT reconstruction of nasal sinus, the 3D stereoscopic prototype was constructed before the surgery. Simulating surgery with Surgicare 5.0 software and then the prosthesis 3D stereoscopic model was shaped. The prosthesis was made quickly and precisely with methacrylate resins according to the model and the print mold before surgery, with supplementary tooth at the bottom of prosthesis. In the surgery, the prosthesis was installed instantly after maxillectomy. The patients were followed up at 1, 3 and 6 month after the surgery, respectively. The facial features and the pronunciation clarity were examined and the questionnaires were carried out in the patients, with comparation by paired t-test. The hollow obturator prosthesis would be replaced by permanent prosthesis made of methacrylate resins at 6 month after the surgery. The hollow obturator prostheses were installed accurately and maxillofacial defects were repaired immediately after maxillectomy in the 13 patients. Postoperative follow-up showed there were significant differences in eyeball sagging (t = 4.67, P < 0.05), mid-facial region collapse (t = 5.67, P < 0.05), and pronunciation clarity (t = 16.38, P < 0.05) between patients with and without prostheses. Questionnaires showed that all the patients were satisfied with the retention of prostheses, the improvement of appearance, the improvement of the symptom of water choking and speech definition. Six months after the surgery, the hollow obturator prostheses were replaced smoothly by permanent prostheses in 11 of the 13 patients. The precise and instant repair of maxillofacial defect by prosthesis after maxillectomy can improve survival quality of patient.

  12. Do CTA measurements of annular diameter, perimeter and area result in different TAVI prosthesis sizes?

    PubMed

    Horehledova, Barbora; Mihl, Casper; Hendriks, Babs M F; Eijsvoogel, Nienke G; Vainer, Jindrich; Veenstra, Leo F; Wildberger, Joachim E; Das, Marco

    2018-06-16

    Incorrect prosthesis size has direct impact on patient outcome after transcatheter aortic valve implantation (TAVI) procedure. Currently, annular diameter, area or perimeter may be used for prosthesis size selection. The aim was to evaluate whether the use different annular dimensions would result in the selection of different prosthesis sizes, when assessed in the same TAVI-candidate during the same phase of a cardiac cycle. Fifty consecutive TAVI-candidates underwent retrospectively ECG-gated computed tomography angiography (CTA). Aortic root dimensions were assessed in the 20% phase of the R-R interval. Annular short diameter, perimeter and area were used to select the prosthesis size, based on the industry recommendations for a self-expandable (Medtronic CoreValve; MCV) and balloon-expandable (Edwards Sapien XT Valve; ESV) valve. Complete agreement on selected prosthesis size amongst all three annular dimensions was observed in 62% (31/50; ESV) and 30% (15/50; MCV). Short aortic annulus measurement resulted in a smaller prosthesis size in 20% (10/50; ESV) and in 60% of cases (30/50; MCV) compared to the size suggested by both annular perimeter and area. In 18% (9/50; ESV) and 10% of cases (5/50; MCV) a larger prosthesis would have been selected based on annular perimeter compared to annular diameter and area. Prosthesis size derived from area was always in agreement with at least one other parameter in all cases. Aortic annulus area appears to be the most robust parameter for TAVI-prosthesis size selection, regardless of the specific prosthesis size. Short aortic annulus diameter may underestimate the prosthesis size, while use of annular perimeter may lead to size overestimation in some cases.

  13. Axillary artery injury secondary to inferior shoulder dislocation.

    PubMed

    Plaga, Brad R; Looby, Peter; Feldhaus, Steven J; Kreutzmann, Karl; Babb, Aaron

    2010-11-01

    Dislocation injuries of the glenohumeral joint are common in the general public and generally are corrected without complication. One serious complication with shoulder dislocations, or the subsequent reduction, is a lesion to the axillary artery. This specific complication is most frequently seen in the elderly population, where vascular structures have become less flexible. Also, these injuries are most common in association with anterior dislocations of the shoulder. To bring awareness to the possibility of axillary artery injury with inferior dislocation of the shoulder, the treatment options, and a review. We report a 15-year-old male athlete who inferiorly dislocated his shoulder during wrestling practice. The injury was reduced at the scene with manual traction and the patient was transferred to our clinic for evaluation. The patient was determined to have a pseudoaneurysm of the axillary artery, and the history and treatment of the illness are presented. Axillary artery injuries secondary to shoulder dislocations are rare, especially in the young athlete, and proper recognition and treatment offer patients a full recovery. Copyright © 2010. Published by Elsevier Inc.

  14. Implementation of the nudged elastic band method in a dislocation dynamics formalism: Application to dislocation nucleation

    NASA Astrophysics Data System (ADS)

    Geslin, Pierre-Antoine; Gatti, Riccardo; Devincre, Benoit; Rodney, David

    2017-11-01

    We propose a framework to study thermally-activated processes in dislocation glide. This approach is based on an implementation of the nudged elastic band method in a nodal mesoscale dislocation dynamics formalism. Special care is paid to develop a variational formulation to ensure convergence to well-defined minimum energy paths. We also propose a methodology to rigorously parametrize the model on atomistic data, including elastic, core and stacking fault contributions. To assess the validity of the model, we investigate the homogeneous nucleation of partial dislocation loops in aluminum, recovering the activation energies and loop shapes obtained with atomistic calculations and extending these calculations to lower applied stresses. The present method is also applied to heterogeneous nucleation on spherical inclusions.

  15. Isolated dorsal dislocation of the tarsal naviculum

    PubMed Central

    Hamdi, Kaziz; Hazem, Ben Ghozlen; Yadh, Zitoun; Faouzi, Abid

    2015-01-01

    Isolated dislocation of the tarsal naviculum is an unusual injury, scarcely reported in the literature. The naviculum is surrounded by the rigid bony and ligamentous support hence fracture dislocation is more common than isolated dislocation. The mechanism and treatment options remain unclear. In this case report, we describe a 31 year old man who sustained an isolated dorsal dislocation of the left tarsal naviculum, without fracture, when he was involved in a motor vehicle collision. The reported mechanism of the dislocation is a hyper plantar flexion force applied to the midfoot, resulting in a transient disruption of the ligamentous support of the naviculum bone, with dorsal displacement of the bone. The patient was treated with open reduction and Krischner-wire fixation of the navicular after the failure of closed reduction. The wires were removed after 6 weeks postoperatively. Physiotherapy for stiffness and midfoot pain was recommended for 2 months. At 6 months postoperatively, limping, midfoot pain and weakness were reported, no X-ray abnormalities were found. The patient returned to his obvious activities with a normal range of motion. PMID:26806978

  16. Multidisciplinary approach for in-deep assessment of joint prosthesis failure.

    PubMed

    Tessarolo, F; Caola, I; Piccoli, F; Dorigotti, P; Demattè, E; Molinari, M; Malavolta, M; Barbareschi, M; Caciagli, P; Nollo, G

    2009-01-01

    In spite of advancement in biomaterials and biomechanics, in development of new osteo-integrative materials and coatings, and in macro- micro- component design, a non negligible fraction of the implanted prosthesis fails before the expected lifetime. A prospective observational clinical study has been conducted to define and apply a set of experimental techniques to in-deep assess the failure of joint prosthesis. Microbiological, histological and micro-structural techniques were implemented to specifically address phenomena occurring at the tissue-implant interface. Results obtained from 27 cases of prosthetic joint failure are discussed in terms of sensitivity and specificity. A procedural flow-chart is finally proposed for the assessment of joint prosthesis failure.

  17. A hierarchical dislocation-grain boundary interaction model based on 3D discrete dislocation dynamics and molecular dynamics

    NASA Astrophysics Data System (ADS)

    Gao, Yuan; Zhuang, Zhuo; You, XiaoChuan

    2011-04-01

    We develop a new hierarchical dislocation-grain boundary (GB) interaction model to predict the mechanical behavior of polycrystalline metals at micro and submicro scales by coupling 3D Discrete Dislocation Dynamics (DDD) simulation with the Molecular Dynamics (MD) simulation. At the microscales, the DDD simulations are responsible for capturing the evolution of dislocation structures; at the nanoscales, the MD simulations are responsible for obtaining the GB energy and ISF energy which are then transferred hierarchically to the DDD level. In the present model, four kinds of dislocation-GB interactions, i.e. transmission, absorption, re-emission and reflection, are all considered. By this methodology, the compression of a Cu micro-sized bi-crystal pillar is studied. We investigate the characteristic mechanical behavior of the bi-crystal compared with that of the single-crystal. Moreover, the comparison between the present penetrable model of GB and the conventional impenetrable model also shows the accuracy and efficiency of the present model.

  18. Utilization of penile prosthesis and male incontinence prosthetics in Saudi Arabia.

    PubMed

    Alwaal, Amjad; Al-Sayyad, Ahmad J

    2017-01-01

    Erectile dysfunction is a prevalent disease affecting over 50% of men between the ages of 40 and 70 years. Penile prosthesis represents the end of the line treatment when other less invasive therapies fail or are contraindicated. Male stress urinary incontinence can significantly diminish quality of life and lead to embarrassment and social withdrawal. Surgical therapies, such as male urethral slings and artificial urinary sphincters (AUS), are considered effective and safe treatments for male stress incontinence. No data exist on the utilization of penile prosthesis or male incontinence surgical treatment in Saudi Arabia. Generally, urological prosthetic surgery is performed either in private hospitals or in government hospitals. Our aim was to assess the trend of penile prosthesis and male incontinence device utilization in Saudi Arabia. We utilized sales' data of penile prosthetics, male slings, and AUS from the only two companies selling these devices in Saudi Arabia (AMS ® and Coloplast ® ), from January 2013 to December 2016. There were 2599 penile prosthesis implantation procedures done in the study period, with 67% of them performed in private institutions. There was a progressively increased use of penile prosthetics which nearly doubled from 2013 to 2016. The main type of prosthesis utilized was the semirigid type 70% versus 11% of the 2-piece inflatable and 17% of the 3-piece inflatable device. Only 10 slings and 31 AUS were inserted during the same study period. There is an increased utilization of penile prosthetics in Saudi Arabia. The private sector performs the majority of penile prosthesis procedures, and most of them are of the semirigid type. The governmental sector is more likely to perform inflatable penile prosthesis and male incontinence device procedures. Male incontinence prosthetics' use is very limited in Saudi Arabia.

  19. Manufacturer-provided effective orifice area index charts and the prevention of prosthesis-patient mismatch.

    PubMed

    House, Chad M; Nelson, William B; Kroshus, Timothy J; Dahiya, Ranjan; Pibarot, Philippe

    2012-01-01

    Prosthesis-patient mismatch (PPM) occurs when an implanted prosthesis is too small relative to the patient's body surface area (BSA). However, mismatch can often be prevented by indexing the expected effective orifice area (EOA) of a prosthesis to the patient's BSA and then selecting the largest implantable prosthesis to avoid mismatch. Previously, prosthesis manufacturers have attempted to simplify this process by providing charts that include the expected EOA for their prosthesis, already indexed into an array of BSA values. One caveat with these charts is that the expected EOA data must truly be reliable, or the charts will misguide the implanting surgeon. Manufacturer-provided charts could be improved by standardizing the EOA data, with one potential source being the hemodynamic data submitted to the United States Food and Drug Administration. This review discusses PPM, manufacturer-provided EOA charts, and the regulation of EOA data.

  20. Production of porous coating on a prosthesis

    DOEpatents

    Sump, Kenneth R.

    1987-01-01

    Preselected surface areas of a prosthesis are covered by a blend of matching primary metallic particles and expendable particles. The particles are compressed and heated to assure that deformation and metallurgical bonding occurs between them and between the primary particles and the surface boundaries of the prosthesis. Porosity is achieved by removal of the expendable material. The result is a coating including discrete bonded particles separated by a network of interconnected voids presenting a homogeneous porous coating about the substrate. It has strength suitable for bone implant usage without intermediate adhesives, and adequate porosity to promote subsequent bone ingrowth.

  1. Can We Improve the Tolerance of an Ocular Prosthesis by Enhancing Its Surface Finish?

    PubMed

    Litwin, Andre S; Worrell, Emma; Roos, Jonathan C P; Edwards, Barry; Malhotra, Raman

    Patients who wear an ocular prosthesis frequently suffer with dry eye symptoms and socket discharge, often on a daily basis. The aim of the study was to determine whether a smoother, optical quality polish of the prosthesis' surface could improve symptoms and wear tolerance. The study was designed as single-center, single-masked, prospective randomized controlled trial. Eighty-eight consecutive patients undergoing annual ocular prosthesis maintenance review were approached from the prosthesis clinic. Forty-one out of 49 eligible patients were recruited. Participants were randomized to either a standard or a higher "optical quality" polish of their prosthesis. At entry to the trial, at 1 month, and 12 months they completed a questionnaire covering cleaning, lubricant use, inflammation, discomfort, and discharge. Lower scores indicated better tolerance of the prosthesis. At each visit, the prosthesis was stained and photographed against a standard background to assess deposit build up. Primary outcome measures were 1) a subjective questionnaire score and 2) an objective assessment of surface deposit build-up on prosthetic eyes by standardized photographic grading. Forty-one patients participated in the study. The median age of their prosthesis was 36 months (range 9 months-40 years). There was no statistically significant difference in questionnaire scores or deposit build up between the 2 groups at baseline. By 12-months, the higher optical quality polish showed a statistically significant reduction in symptoms and frequency of discharge (2.19 vs. 3.85; p = 0.05-lower scores better). Scoring of the prosthesis' deposit build-up showed a significant difference at 1 month, but this was not sustained at 12 months. Creating an optical quality finish to an ocular prosthesis reduces deposit build up on artificial eyes. The authors found this modification improved patient tolerance at 12 months.

  2. Thermodynamic theory of dislocation-enabled plasticity

    NASA Astrophysics Data System (ADS)

    Langer, J. S.

    2017-11-01

    The thermodynamic theory of dislocation-enabled plasticity is based on two unconventional hypotheses. The first of these is that a system of dislocations, driven by external forces and irreversibly exchanging heat with its environment, must be characterized by a thermodynamically defined effective temperature that is not the same as the ordinary temperature. The second hypothesis is that the overwhelmingly dominant mechanism controlling plastic deformation is thermally activated depinning of entangled pairs of dislocations. This paper consists of a systematic reformulation of this theory followed by examples of its use in analyses of experimentally observed phenomena including strain hardening, grain-size (Hall-Petch) effects, yielding transitions, and adiabatic shear banding.

  3. Elasticity and dislocation inelasticity of crystals

    NASA Astrophysics Data System (ADS)

    Nikanorov, S. P.; Kardashev, B. K.

    The use of methods of physical acoustics for studying the elasticity and dislocation inelasticity of crystals is discussed, as is the application of the results of such studies to the analysis of interatomic and lattice defect interactions. The analysis of the potential functions determining the energy of interatomic interactions is based on an analysis of the elastic properties of crystals over a wide temperature range. The data on the dislocation structure and the interaction between dislocations and point defects are obtained from a study of inelastic effects. Particular attention is given to the relationship between microplastic effects under conditions of elastic oscillations and the initial stage of plastic deformation.

  4. Towards a Completely Implantable, Light-Sensitive Intraocular Retinal Prosthesis

    DTIC Science & Technology

    2001-10-25

    electronic retinal prosthesis is under development to treat retinitis pigmentosa and age-related macular degeneration, two presently incurable...34Preservation of the inner retina in retinitis pigmentosa . A morphometric analysis," Arch Ophthalmol, vol. 115, no. 4, pp. 511-515, Apr.1997...Towards a completely implantable, light-sensitive intraocular retinal prosthesis. M.S. Humayun, J.D. Weiland, B. Justus1, C. Merrit1, J. Whalen, D

  5. Pair Interaction of Dislocations in Two-Dimensional Crystals

    NASA Astrophysics Data System (ADS)

    Eisenmann, C.; Gasser, U.; Keim, P.; Maret, G.; von Grünberg, H. H.

    2005-10-01

    The pair interaction between crystal dislocations is systematically explored by analyzing particle trajectories of two-dimensional colloidal crystals measured by video microscopy. The resulting pair energies are compared to Monte Carlo data and to predictions derived from the standard Hamiltonian of the elastic theory of dislocations. Good agreement is found with respect to the distance and temperature dependence of the interaction potential, but not regarding the angle dependence where discrete lattice effects become important. Our results on the whole confirm that the dislocation Hamiltonian allows a quantitative understanding of the formation and interaction energies of dislocations in two-dimensional crystals.

  6. Thermal activation of dislocations in large scale obstacle bypass

    NASA Astrophysics Data System (ADS)

    Sobie, Cameron; Capolungo, Laurent; McDowell, David L.; Martinez, Enrique

    2017-08-01

    Dislocation dynamics simulations have been used extensively to predict hardening caused by dislocation-obstacle interactions, including irradiation defect hardening in the athermal case. Incorporating the role of thermal energy on these interactions is possible with a framework provided by harmonic transition state theory (HTST) enabling direct access to thermally activated reaction rates using the Arrhenius equation, including rates of dislocation-obstacle bypass processes. Moving beyond unit dislocation-defect reactions to a representative environment containing a large number of defects requires coarse-graining the activation energy barriers of a population of obstacles into an effective energy barrier that accurately represents the large scale collective process. The work presented here investigates the relationship between unit dislocation-defect bypass processes and the distribution of activation energy barriers calculated for ensemble bypass processes. A significant difference between these cases is observed, which is attributed to the inherent cooperative nature of dislocation bypass processes. In addition to the dislocation-defect interaction, the morphology of the dislocation segments pinned to the defects play an important role on the activation energies for bypass. A phenomenological model for activation energy stress dependence is shown to describe well the effect of a distribution of activation energies, and a probabilistic activation energy model incorporating the stress distribution in a material is presented.

  7. Early history of operative treatment of patellar fractures.

    PubMed

    Bartoníček, Jan; Rammelt, Stefan

    2015-11-01

    The presented overview shows that the first efforts to address patellar fractures by operative treatment, although sporadic, emerged in the pre-antiseptic era. Introduction of Lister's antiseptic method in Great Britain, Germany and the USA in 1877-1882 contributed to a new, progressive trend in the treatment of fractures of the patella as well as of other bones. The authors, using Lister's antiseptic method, evaluated three basic aspects in their operations, namely healing of the surgical wound without infective complications, achievement of bony union and a good functional outcome, i.e. restoring the range of motion in the knee, even if limited in most cases. The majority of them used a longitudinal incision and fixation by a silver wire.

  8. Total Ossicular Replacement Prosthesis: A New Fat Interposition Technique.

    PubMed

    Saliba, Issam; Sabbah, Valérie; Poirier, Jackie Bibeau

    2018-01-01

    To compare audiometric results between the standard total ossicular replacement prosthesis (TORP-S) and a new fat interposition total ossicular replacement prosthesis (TORP-F) in pediatric and adult patients and to assess the complication and the undesirable outcome. This is a retrospective study. This study included 104 patients who had undergone titanium implants with TORP-F and 54 patients who had undergone the procedure with TORP-S between 2008 and 2013 in our tertiary care centers. The new technique consists of interposing a fat graft between the 4 legs of the universal titanium prosthesis (Medtronic Xomed Inc, Jacksonville, FL, USA) to provide a more stable TORP in the ovale window niche. Normally, this prosthesis is designed to fit on the stapes' head as a partial ossicular replacement prosthesis. The postoperative air-bone gap less than 25 dB for the combined cohort was 69.2% and 41.7% for the TORP-F and the TORP-S groups, respectively. The mean follow-up was 17 months postoperatively. By stratifying data, the pediatric cohort shows 56.5% in the TORP-F group (n = 52) compared with 40% in the TORP-S group (n = 29). However, the adult cohort shows 79.3% in the TORP-F group (n = 52) compared with 43.75% in the TORP-S group (n = 25). These improvements in hearing were statistically significant. There were no statistically significant differences in the speech discrimination scores. The only undesirable outcome that was statistically different between the 2 groups was the prosthesis displacement: 7% in the TORP-F group compared with 19% in the TORP-S group ( P  = .03). The interposition of a fat graft between the legs of the titanium implants (TORP-F) provides superior hearing results compared with a standard procedure (TORP-S) in pediatric and adult populations because of its better stability in the oval window niche.

  9. Total Ossicular Replacement Prosthesis: A New Fat Interposition Technique

    PubMed Central

    Saliba, Issam; Sabbah, Valérie; Poirier, Jackie Bibeau

    2018-01-01

    Objective: To compare audiometric results between the standard total ossicular replacement prosthesis (TORP-S) and a new fat interposition total ossicular replacement prosthesis (TORP-F) in pediatric and adult patients and to assess the complication and the undesirable outcome. Study design: This is a retrospective study. Methods: This study included 104 patients who had undergone titanium implants with TORP-F and 54 patients who had undergone the procedure with TORP-S between 2008 and 2013 in our tertiary care centers. The new technique consists of interposing a fat graft between the 4 legs of the universal titanium prosthesis (Medtronic Xomed Inc, Jacksonville, FL, USA) to provide a more stable TORP in the ovale window niche. Normally, this prosthesis is designed to fit on the stapes’ head as a partial ossicular replacement prosthesis. Results: The postoperative air-bone gap less than 25 dB for the combined cohort was 69.2% and 41.7% for the TORP-F and the TORP-S groups, respectively. The mean follow-up was 17 months postoperatively. By stratifying data, the pediatric cohort shows 56.5% in the TORP-F group (n = 52) compared with 40% in the TORP-S group (n = 29). However, the adult cohort shows 79.3% in the TORP-F group (n = 52) compared with 43.75% in the TORP-S group (n = 25). These improvements in hearing were statistically significant. There were no statistically significant differences in the speech discrimination scores. The only undesirable outcome that was statistically different between the 2 groups was the prosthesis displacement: 7% in the TORP-F group compared with 19% in the TORP-S group (P = .03). Conclusions: The interposition of a fat graft between the legs of the titanium implants (TORP-F) provides superior hearing results compared with a standard procedure (TORP-S) in pediatric and adult populations because of its better stability in the oval window niche. PMID:29326537

  10. Influence of strain on dislocation core in silicon

    NASA Astrophysics Data System (ADS)

    Pizzagalli, L.; Godet, J.; Brochard, S.

    2018-05-01

    First principles, density functional-based tight binding and semi-empirical interatomic potentials calculations are performed to analyse the influence of large strains on the structure and stability of a 60? dislocation in silicon. Such strains typically arise during the mechanical testing of nanostructures like nanopillars or nanoparticles. We focus on bi-axial strains in the plane normal to the dislocation line. Our calculations surprisingly reveal that the dislocation core structure largely depends on the applied strain, for strain levels of about 5%. In the particular case of bi-axial compression, the transformation of the dislocation to a locally disordered configuration occurs for similar strain magnitudes. The formation of an opening, however, requires larger strains, of about 7.5%. Furthermore, our results suggest that electronic structure methods should be favoured to model dislocation cores in case of large strains whenever possible.

  11. The relationship between strain geometry and geometrically necessary dislocations

    NASA Astrophysics Data System (ADS)

    Hansen, Lars; Wallis, David

    2016-04-01

    The kinematics of past deformations are often a primary goal in structural analyses of strained rocks. Details of the strain geometry, in particular, can help distinguish hypotheses about large-scale tectonic phenomena. Microstructural indicators of strain geometry have been heavily utilized to investigate large-scale kinematics. However, many of the existing techniques require structures for which the initial morphology is known, and those structures must undergo the same deformation as imposed macroscopically. Many deformed rocks do not exhibit such convenient features, and therefore the strain geometry is often difficult (if not impossible) to ascertain. Alternatively, crystallographic textures contain information about the strain geometry, but the influence of strain geometry can be difficult to separate from other environmental factors that might affect slip system activity and therefore the textural evolution. Here we explore the ability for geometrically necessary dislocations to record information about the deformation geometry. It is well known that crystallographic slip due to the motion of dislocations yields macroscopic plastic strain, and the mathematics are established to relate dislocation glide on multiple slip systems to the strain tensor of a crystal. This theoretical description generally assumes that dislocations propagate across the entire crystal. However, at any point during the deformation, dislocations are present that have not fully transected the crystal, existing either as free dislocations or as dislocations organized into substructures like subgrain boundaries. These dislocations can remain in the lattice after deformation if the crystal is quenched sufficiently fast, and we hypothesize that this residual dislocation population can be linked to the plastic strain geometry in a quantitative manner. To test this hypothesis, we use high-resolution electron backscatter diffraction to measure lattice curvatures in experimentally deformed

  12. A combined procedure with Bereiter-type trochleoplasty leads to a stable patellofemoral joint at 5-year follow-up.

    PubMed

    Wind, Rutger J P; Heesterbeek, Petra J C; Wymenga, Ate B

    2018-06-11

    Trochlear dysplasia is a major risk factor predisposing to patellar instability and has been reported to occur in up to 85% of patients with recurrent patellar dislocation. Different operative techniques have been described to correct trochlear dysplasia, including the Bereiter technique, in which subchondral bone is removed and the cartilage can be compressed into a U-shaped groove. The hypothesis was that after a Bereiter-type trochleoplasty combined with medialisation of the tibial tubercle and MPFL reconstruction, patellar pain and instability decreased and anatomic reconstruction can be seen radiographically after 5-year follow-up. Between 2004 and 2011, a combined procedure including Bereiter-type trochleoplasty was performed on 21 consecutively included patients (22 knees) with objective patellar instability and severe trochlear dysplasia. Instability and pain were assessed preoperatively and 3, 6, 12, 24 and 60 months postoperatively with the visual analogue scale (VAS) for pain and instability, Kujala, International Knee Documentation Committee Subjective Knee Evaluation (IKDC SKE) and Short Form Health Survey (SF-36). Pre- and postoperatively, a true lateral radiograph was made to investigate the presence of the crossing sign and to measure the trochlear bump and trochlear depth, as well as a sunrise patella view to measure the sulcus angle. VAS pain and instability, Kujala and IKDC SKE improved significantly 5 years after trochleoplasty (p < 0.05). SF-36 showed no significant improvement. None of the patients reported patellar dislocations postoperatively. Sport activities remained limited. Postoperative radiographs showed no crossing sign. There was a significant increase in trochlear depth (p < 0.0001) and also a significant decrease in trochlear bump and sulcus angle (both p < 0.0001). A combined procedure consisting of Bereiter-type trochleoplasty, medialisation of the tibial tubercle and MPFL reconstruction in patients with objective

  13. System training and assessment in simultaneous proportional myoelectric prosthesis control

    PubMed Central

    2014-01-01

    Background Pattern recognition control of prosthetic hands take inputs from one or more myoelectric sensors and controls one or more degrees of freedom. However, most systems created allow only sequential control of one motion class at a time. Additionally, only recently have researchers demonstrated proportional myoelectric control in such systems, an option that is believed to make fine control easier for the user. Recent developments suggest improved reliability if the user follows a so-called prosthesis guided training (PGT) scheme. Methods In this study, a system for simultaneous proportional myoelectric control has been developed for a hand prosthesis with two motor functions (hand open/close, and wrist pro-/supination). The prosthesis has been used with a prosthesis socket equivalent designed for normally-limbed subjects. An extended version of PGT was developed for use with proportional control. The control system’s performance was tested for two subjects in the Clothespin Relocation Task and the Southampton Hand Assessment Procedure (SHAP). Simultaneous proportional control was compared with three other control strategies implemented on the same prosthesis: mutex proportional control (the same system but with simultaneous control disabled), mutex on-off control, and a more traditional, sequential proportional control system with co-contractions for state switching. Results The practical tests indicate that the simultaneous proportional control strategy and the two mutex-based pattern recognition strategies performed equally well, and superiorly to the more traditional sequential strategy according to the chosen outcome measures. Conclusions This is the first simultaneous proportional myoelectric control system demonstrated on a prosthesis affixed to the forearm of a subject. The study illustrates that PGT is a promising system training method for proportional control. Due to the limited number of subjects in this study, no definite conclusions can be

  14. [Experimental study of dislocations of the scapulohumeral joint].

    PubMed

    Gagey, O; Gagey, N; Boisrenoult, P; Hue, E; Mazas, F

    1993-01-01

    One may produce easily an experimental dislocation (anterior or erecta) of the scapulohumeral joint. The authors discuss, the experimental model then they describe the anatomical lesion produced through the experimental dislocation of 32 shoulders and the correlation observed after RMI assessment of 24 recurrent dislocations. The tear of the inferior glenohumeral ligament is constant, in 20 per cent of the cases the tear lies on the anterior aspect of the glenoid, in the other cases the tear was found on its humeral side. Whatever the situation of the tear of the inferior glenohumeral ligament, the lesion of the labrum was constant. The erecta dislocation was produced with the same movement but with a particular tear of the glenohumeral ligament: the tear was longitudinal. The experimental dislocation needs, in 7 or 8 cases, a desinsertion of the deep aspect of the rotator cuff. The Hill Sachs lesion occurs when the humerus falls along the chest wall after the dislocation. In 50 per cent of the patients, MRI shows modifications of the cuff which are compatible with our results. Hills Sachs lesions appear to be constant after MRI examination.

  15. How to identify dislocations in molecular dynamics simulations?

    NASA Astrophysics Data System (ADS)

    Li, Duo; Wang, FengChao; Yang, ZhenYu; Zhao, YaPu

    2014-12-01

    Dislocations are of great importance in revealing the underlying mechanisms of deformed solid crystals. With the development of computational facilities and technologies, the observations of dislocations at atomic level through numerical simulations are permitted. Molecular dynamics (MD) simulation suggests itself as a powerful tool for understanding and visualizing the creation of dislocations as well as the evolution of crystal defects. However, the numerical results from the large-scale MD simulations are not very illuminating by themselves and there exist various techniques for analyzing dislocations and the deformed crystal structures. Thus, it is a big challenge for the beginners in this community to choose a proper method to start their investigations. In this review, we summarized and discussed up to twelve existing structure characterization methods in MD simulations of deformed crystal solids. A comprehensive comparison was made between the advantages and disadvantages of these typical techniques. We also examined some of the recent advances in the dynamics of dislocations related to the hydraulic fracturing. It was found that the dislocation emission has a significant effect on the propagation and bifurcation of the crack tip in the hydraulic fracturing.

  16. Transtibial prosthesis suspension failure during skydiving freefall: a case report.

    PubMed

    Gordon, Assaf T; Land, Rebekah M

    2009-01-01

    This report describes the unusual case of an everyday-use prosthesis suspension system failure during the freefall phase of a skydiving jump. The case individual was a 53-year-old male with a left transtibial amputation secondary to trauma. He used his everyday prosthesis, a transtibial endoskeleton with push-button, plunger-releasing, pin-locking silicon liner suction suspension and a neoprene knee suspension sleeve, for a standard recreational tandem skydive. Within seconds of exiting the plane, the suspension systems failed, resulting in the complete prosthesis floating away. Several factors may have led to suspension system failure, including an inadequate seal and material design of the knee suspension sleeve and liner, lack of auxiliary suspension mechanisms, and lack of a safety cover overlying the push-button release mechanism. This is the first report, to our knowledge, to discuss prosthetic issues specifically related to skydiving. While amputees are to be encouraged to participate in this extreme sport, special modifications to everyday components may be necessary to reduce the possibility of prosthesis failure during freefall, parachute deployment, and landing.

  17. Referral of sensation to an advanced humanoid robotic hand prosthesis.

    PubMed

    Rosén, Birgitta; Ehrsson, H Henrik; Antfolk, Christian; Cipriani, Christian; Sebelius, Fredrik; Lundborg, Göran

    2009-01-01

    Hand prostheses that are currently available on the market are used by amputees to only a limited extent, partly because of lack of sensory feedback from the artificial hand. We report a pilot study that showed how amputees can experience a robot-like advanced hand prosthesis as part of their own body. We induced a perceptual illusion by which touch applied to the stump of the arm was experienced from the artificial hand. This illusion was elicited by applying synchronous tactile stimulation to the hidden amputation stump and the robotic hand prosthesis in full view. In five people who had had upper limb amputations this stimulation caused referral touch sensation from the stump to the artificial hand, and the prosthesis was experienced more like a real hand. We also showed that this illusion can work when the amputee controls the movements of the artificial hand by recordings of the arm muscle activity with electromyograms. These observations indicate that the previously described "rubber hand illusion" is also valid for an advanced hand prosthesis, even when it has a robotic-like appearance.

  18. Design and characterization of a powered elbow prosthesis.

    PubMed

    Bennett, Daniel A; Mitchell, Jason; Goldfarb, Michael

    2015-01-01

    This paper describes the design of a powered elbow prosthesis, which incorporates a belt and cable drive transmission with a brushless DC motor to achieve an output torque of approximately 18.4 Nm, a backdrive torque of 1.5 Nm, and a speed of up to 360 deg/s while remaining within the anthropomorphic envelope with regard to mass and size. The measured torque and speed of the prosthesis is commensurate with nominal capability of the natural limb (for purposes of performing activities of daily living).

  19. A Simplified Technique for Fabrication of Orbital Prosthesis

    PubMed Central

    Thakral, G.K.; Mohapatra, Abhilash; Seth, Jyotsna; Vashisht, Pallavi

    2014-01-01

    Eye is a vital organ not only for vision, but also an important component of facial expression, and over-all personality of a person. Loss of eye, apart from leading to impaired vision has a crippling effect on the psychology of the patient. Prosthodontic rehabilitation of such cases includes fabrication of prosthesis by acrylic resin, silicone and implants. However, not all patients are willing to use implants for maxillofacial rehabilitation. Therefore, a custom made orbital prosthesis serves as an affordable and satisfactory alternative. PMID:25121068

  20. Strain field mapping of dislocations in a Ge/Si heterostructure.

    PubMed

    Liu, Quanlong; Zhao, Chunwang; Su, Shaojian; Li, Jijun; Xing, Yongming; Cheng, Buwen

    2013-01-01

    Ge/Si heterostructure with fully strain-relaxed Ge film was grown on a Si (001) substrate by using a two-step process by ultra-high vacuum chemical vapor deposition. The dislocations in the Ge/Si heterostructure were experimentally investigated by high-resolution transmission electron microscopy (HRTEM). The dislocations at the Ge/Si interface were identified to be 90° full-edge dislocations, which are the most efficient way for obtaining a fully relaxed Ge film. The only defect found in the Ge epitaxial film was a 60° dislocation. The nanoscale strain field of the dislocations was mapped by geometric phase analysis technique from the HRTEM image. The strain field around the edge component of the 60° dislocation core was compared with those of the Peierls-Nabarro and Foreman dislocation models. Comparison results show that the Foreman model with a = 1.5 can describe appropriately the strain field around the edge component of a 60° dislocation core in a relaxed Ge film on a Si substrate.