Sample records for patellar tendon loading

  1. Landing strategies of athletes with an asymptomatic patellar tendon abnormality.

    PubMed

    Edwards, Suzi; Steele, Julie R; McGhee, Deirdre E; Beattie, Sue; Purdam, Craig; Cook, Jill L

    2010-11-01

    Risk factors associated with a clinical presentation of patellar tendinopathy are patellar tendon ultrasonographic abnormality (PTA) and excessive loading. It remains unknown whether characteristics of an athlete's landing technique contribute to this excessive patellar tendon loading. This study investigated whether asymptomatic athletes with and without PTA had different landing strategies and hypothesized that asymptomatic athletes with a PTA would create higher patellar tendon loading and a different lower-limb landing strategy compared with athletes with normal patellar tendons. Seven athletes with no previous history or clinical signs of patellar tendon injury with a PTA were matched to athletes with normal patellar tendons (controls). Participants performed five successful trials of a stop-jump task, which involved a simultaneous two-foot horizontal and then vertical landing. During each trial, the participants' ground reaction forces and lower-limb electromyographic data were recorded, the three-dimensional kinematics measured, and the peak patellar tendon force calculated by dividing the net knee joint moment by the patellar tendon moment arm. Significant between-group differences in landing technique were mostly observed during the horizontal landing phase. Participants with a PTA created similar patellar tendon loading to the controls, but with altered sequencing, by landing with significantly greater knee flexion and extending their hips while the controls flexed their hips as they landed, reflecting a different muscle recruitment order compared with the PTA group. The crucial part in the development of PTA and, in turn, patellar tendinopathy may not be the magnitude of the patellar tendon load but rather the loading patterns. This research provides clinicians with important landing assessment criteria against which to identify athletes at risk of developing patellar tendinopathy.

  2. Does the adolescent patellar tendon respond to 5 days of cumulative load during a volleyball tournament?

    PubMed

    van Ark, M; Docking, S I; van den Akker-Scheek, I; Rudavsky, A; Rio, E; Zwerver, J; Cook, J L

    2016-02-01

    Patellar tendinopathy (jumper's knee) has a high prevalence in jumping athletes. Excessive load on the patellar tendon through high volumes of training and competition is an important risk factor. Structural changes in the tendon are related to a higher risk of developing patellar tendinopathy. The critical tendon load that affects tendon structure is unknown. The aim of this study was to investigate patellar tendon structure on each day of a 5-day volleyball tournament in an adolescent population (16-18 years). The right patellar tendon of 41 players in the Australian Volleyball Schools Cup was scanned with ultrasound tissue characterization (UTC) on every day of the tournament (Monday to Friday). UTC can quantify structure of a tendon into four echo types based on the stability of the echo pattern. Generalized estimating equations (GEE) were used to test for change of echo type I and II over the tournament days. Participants played between eight and nine matches during the tournament. GEE analysis showed no significant change of echo type percentages of echo type I (Wald chi-square = 4.603, d.f. = 4, P = 0.331) and echo type II (Wald chi-square = 6.070, d.f. = 4, P = 0.194) over time. This study shows that patellar tendon structure of 16-18-year-old volleyball players is not affected during 5 days of cumulative loading during a volleyball tournament. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Effect of Implanting a Soft Tissue Autograft in a Central-Third Patellar Tendon Defect: Biomechanical and Histological Comparisons

    PubMed Central

    Kinneberg, Kirsten R. C.; Galloway, Marc T.; Butler, David L.; Shearn, Jason T.

    2011-01-01

    Previous studies by our laboratory have demonstrated that implanting a stiffer tissue engineered construct at surgery is positively correlated with repair tissue stiffness at 12 weeks. The objective of this study was to test this correlation by implanting a construct that matches normal tissue biomechanical properties. To do this, we utilized a soft tissue patellar tendon autograft to repair a central-third patellar tendon defect. Patellar tendon auto-graft repairs were contrasted against an unfilled defect repaired by natural healing (NH). We hypothesized that after 12 weeks, patellar tendon autograft repairs would have biomechanical properties superior to NH. Bilateral defects were established in the central-third patellar tendon of skeletally mature (one year old), female New Zealand White rabbits (n = 10). In one limb, the excised tissue, the patellar tendon autograft, was sutured into the defect site. In the contralateral limb, the defect was left empty (natural healing). After 12 weeks of recovery, the animals were euthanized and their limbs were dedicated to bio-mechanical (n = 7) or histological (n = 3) evaluations. Only stiffness was improved by treatment with patellar tendon autograft relative to natural healing (p = 0.009). Additionally, neither the patellar tendon autograft nor natural healing repairs regenerated a normal zonal insertion site between the tendon and bone. Immunohistochemical staining for collagen type II demonstrated that fibrocartilage-like tissue was regenerated at the tendon-bone interface for both repairs. However, the tissue was disorganized. Insufficient tissue integration at the tendon-to-bone junction led to repair tissue failure at the insertion site during testing. It is important to re-establish the tendon-to-bone insertion site because it provides joint stability and enables force transmission from muscle to tendon and subsequent loading of the tendon. Without loading, tendon mechanical properties deteriorate. Future studies by our laboratory will investigate potential strategies to improve patellar tendon autograft integration into bone using this model. [DOI: 10.1115/1.4004948] PMID:22010737

  4. Patellar Tendon Repair Augmentation With a Knotless Suture Anchor Internal Brace: A Biomechanical Cadaveric Study.

    PubMed

    Rothfeld, Alex; Pawlak, Amanda; Liebler, Stephenie A H; Morris, Michael; Paci, James M

    2018-04-01

    Patellar tendon repair with braided polyethylene suture alone is subject to knot slippage and failure. Several techniques to augment the primary repair have been described. Purpose/Hypothesis: The purpose was to evaluate a novel patellar tendon repair technique augmented with a knotless suture anchor internal brace with suture tape (SAIB). The hypothesis was that this technique would be biomechanically superior to a nonaugmented repair and equivalent to a standard augmentation with an 18-gauge steel wire. Controlled laboratory study. Midsubstance patellar tendon tears were created in 32 human cadaveric knees. Two comparison groups were created. Group 1 compared #2 supersuture repair without augmentation to #2 supersuture repair with SAIB augmentation. Group 2 compared #2 supersuture repair with an 18-gauge stainless steel cerclage wire augmentation to #2 supersuture repair with SAIB augmentation. The specimens were potted and biomechanically loaded on a materials testing machine. Yield load, maximum load, mode of failure, plastic displacement, elastic displacement, and total displacement were calculated for each sample. Standard statistical analysis was performed. There was a statistically significant increase in the mean ± SD yield load and maximum load in the SAIB augmentation group compared with supersuture alone (mean yield load: 646 ± 202 N vs 229 ± 60 N; mean maximum load: 868 ± 162 N vs 365 ± 54 N; P < .001). Group 2 showed no statistically significant differences between the augmented repairs (mean yield load: 495 ± 213 N vs 566 ± 172 N; P = .476; mean maximum load: 737 ± 210 N vs 697 ± 130 N; P = .721). Patellar tendon repair augmented with SAIB is biomechanically superior to repair without augmentation and is equivalent to repair with augmentation with an 18-gauge stainless steel cerclage wire. This novel patellar tendon repair augmentation is equivalent to standard 18-gauge wire augmentation at time zero. It does not require a second surgery for removal, and it is biomechanically superior to primary repair alone.

  5. Patellar tendon load in different types of eccentric squats.

    PubMed

    Frohm, A; Halvorsen, K; Thorstensson, A

    2007-07-01

    Differences in mechanical loading of the patellar tendon have been suggested as a reason for varying effects in rehabilitation of patellar tendinopathy using different eccentric squat exercises and devices. The aim was to characterize the magnitude and pattern of mechanical load at the knee and on the patellar tendon during four types of eccentric squat. Subjects performed squats with a submaximal free weight and with maximal effort in a device for eccentric overloading (Bromsman), on a decline board and horizontal surface. Kinematics was recorded with a motion-capture system, reaction forces with force plates, and electromyography from three leg muscles with surface electrodes. Inverse dynamics was used to calculate knee joint kinetics. Eccentric work, mean and peak patellar tendon force, and angle at peak force were greater (25-30%) for squats on decline board compared to horizontal surface with free weight, but not in Bromsman. Higher knee load forces (60-80%), but not work, were observed with Bromsman than free weight. Angular excursions at the knee and ankle were larger with decline board, particularly with free weight, and smaller in Bromsman than with free weight. Mean electromyography was greater on a decline board for gastrocnemius (13%) and vastus medialis (6%) with free weight, but in Bromsman only for gastrocnemius (7%). The results demonstrated clear differences in the biomechanical loading on the knee during different squat exercises. Quantification of such differences provides information that could be used to explain differences in rehabilitation effects as well as in designing more optimal rehabilitation exercises for patellar tendinopathy.

  6. Decline eccentric squats increases patellar tendon loading compared to standard eccentric squats.

    PubMed

    Kongsgaard, M; Aagaard, P; Roikjaer, S; Olsen, D; Jensen, M; Langberg, H; Magnusson, S P

    2006-08-01

    Recent studies have shown excellent clinical results using eccentric squat training on a 25 degrees decline board to treat patellar tendinopathy. It remains unknown why therapeutic management of patellar tendinopathy using decline eccentric squats offer superior clinical efficacy compared to standard horizontal eccentric squats. This study aimed to compare electromyography activity, patellar tendon strain and joint angle kinematics during standard and decline eccentric squats. Thirteen subjects performed unilateral eccentric squats on flat-and a 25 degrees decline surface. During the squats, electromyography activity was obtained in eight representative muscles. Also, ankle, knee and hip joint goniometry was obtained. Additionally, patellar tendon strain was measured in vivo using ultrasonography as subjects maintained a unilateral isometric 90 degrees knee angle squat position on either flat or 25 degrees decline surface. Patellar tendon strain was significantly greater (P<0.05) during the squat position on the decline surface compared to the standard surface. The stop angles of the ankle and hip joints were significantly smaller during the decline compared to the standard squats (P<0.001, P<0.05). Normalized mean electromyography amplitudes of the knee extensor muscles were significantly greater during the decline compared to the standard squats (P<0.05). Hamstring and calf muscle mean electromyography did not differ, respectively, between standard and decline squats. The use of a 25 degrees decline board increases the load and the strain of the patellar tendon during unilateral eccentric squats. This finding likely explains previous reports of superior clinical efficacy of decline eccentric squats in the rehabilitative management of patellar tendinopathy.

  7. Achilles and patellar tendinopathy display opposite changes in elastic properties: A shear wave elastography study.

    PubMed

    Coombes, B K; Tucker, K; Vicenzino, B; Vuvan, V; Mellor, R; Heales, L; Nordez, A; Hug, F

    2018-03-01

    To compare tendon elastic and structural properties of healthy individuals with those with Achilles or patellar tendinopathy. Sixty-seven participants (22 Achilles tendinopathy, 17 patellar tendinopathy, and 28 healthy controls) were recruited between March 2015 and March 2016. Shear wave velocity (SWV), an index of tissue elastic modulus, and tendon thickness were measured bilaterally at mid-tendon and insertional regions of Achilles and patellar tendons by an examiner blinded to group. Analysis of covariance, adjusted for age, body mass index, and sex was used to compare differences in tendon thickness and SWV between the two tendinopathy groups (relative to controls) and regions. Tendon thickness was included as a covariate for analysis of SWV. Compared to controls, participants with Achilles tendinopathy had lower SWV at the distal insertion (Mean difference MD; 95% CI: -1.56; -2.49 to -0.62 m/s; P < .001) and greater thickness at the mid-tendon (MD 0.19; 0.05-0.33 cm; P = .007). Compared to controls, participants with patellar tendinopathy had higher SWV at both regions (MD 1.25; 0.40-2.10 m/s; P = .005) and greater thickness proximally (MD 0.17; 0.06-0.29 cm; P = .003). Compared to controls, participants with Achilles and patellar tendinopathy displayed lower Achilles tendon elastic modulus and higher patellar tendon elastic modulus, respectively. More research is needed to explore whether maturation, aging, or chronic load underlie these findings and whether current management programs for Achilles and patellar tendinopathy need to be tailored to the tendon. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Biomechanical Assessment of Patellar Advancement Procedures for Patella Alta.

    PubMed

    Seidl, Adam; Baldini, Todd; Krughoff, Kevin; Shapiro, Joshua A; Lindeque, Bennie; Rhodes, Jason; Carollo, James

    2016-05-01

    Crouch gait deformity is common in children with cerebral palsy and often is associated with patella alta. Patellar tendon advancement typically is used to correct patella alta and restore normal knee mechanics. The purpose of this study was to determine the mechanical strength of surgical constructs used for fixation during patellar advancement procedures. This study used a cadaveric model to determine which of 3 surgical techniques is biomechanically optimal for patellar tendon advancement in treating patella alta. Twenty-four human cadaveric knees (8 per group) were prepared using 1 of 3 different common surgical techniques: tibial tubercle osteotomy, patellar tendon partial resection and repair at the distal patella, and patellar tendon imbrication. The patella was loaded from 25 to 250 N at 1 Hz for 1000 cycles. A significant difference in patella displacement under cyclical loading was found between surgical techniques. Tibial tubercle osteotomy exhibited significantly less displacement under cyclical loading than distal patella excision and repair (P<.0001) or imbrication (P=.0088). Imbrication exhibited significantly less displacement than distal patella excision and repair (P=.0006). Tibial tubercle osteotomy survived longest. Based on failure criteria of 5 mm of displacement, tibial tubercle osteotomy lasted between 250 and 500 cycles. The other 2 techniques failed by 25 cycles. This study offers quantitative evidence regarding the relative mechanical strength of each construct and may influence choice of surgical technique. [Orthopedics. 2016; 39(3):e492-e497.]. Copyright 2016, SLACK Incorporated.

  9. Previously identified patellar tendinopathy risk factors differ between elite and sub-elite volleyball players.

    PubMed

    Janssen, I; Steele, J R; Munro, B J; Brown, N A T

    2015-06-01

    Patellar tendinopathy is the most common knee injury incurred in volleyball, with its prevalence in elite athletes more than three times that of their sub-elite counterparts. The purpose of this study was to determine whether patellar tendinopathy risk factors differed between elite and sub-elite male volleyball players. Nine elite and nine sub-elite male volleyball players performed a lateral stop-jump block movement. Maximum vertical jump, training history, muscle extensibility and strength, three-dimensional landing kinematics (250 Hz), along with lower limb neuromuscular activation patterns (1500 Hz), and patellar tendon loading were collected during each trial. Multivariate analyses of variance (P < 0.05) assessed for between-group differences in risk factors or patellar tendon loading. Significant interaction effects were further evaluated using post-hoc univariate analysis of variance tests. Landing kinematics, neuromuscular activation patterns, patellar tendon loading, and most of the previously identified risk factors did not differ between the elite and sub-elite players. However, elite players participated in a higher training volume and had less quadriceps extensibility than sub-elite players. Therefore, high training volume is likely the primary contributor to the injury discrepancy between elite and sub-elite volleyball players. Interventions designed to reduce landing frequency and improve quadriceps extensibility are recommended to reduce patellar tendinopathy prevalence in volleyball players. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Changes in Indirect Markers of Muscle Damage and Tendons After Daily Drop Jumping Exercise with Rapid Load Increase

    PubMed Central

    Paleckis, Vidas; Mickevičius, Mantas; Snieckus, Audrius; Streckis, Vytautas; Pääsuke, Mati; Rutkauskas, Saulius; Steponavičiūtė, Rasa; Skurvydas, Albertas; Kamandulis, Sigitas

    2015-01-01

    The aim of this study was to assess changes in indirect markers of muscle damage and type I collagen degradation, as well as, patellar and Achilles tendon morphological differences during nine daily drop-jumps sessions with constant load alternated with rapid increases in load to test the hypothesis that frequent drop-jump training results in negative muscular and tendon adaptation. Young men (n = 9) performed daily drop jump workouts with progression every 3 days in terms of number of jumps, platform height and squat amplitude. Voluntary and electrically evoked knee extensor torque, muscle soreness, blood plasma creatine kinase (CK) activity and carboxyterminal cross-linked telopeptide (ICTP), patellar and Achilles tendon thickness and cross-sectional area (CSA) were assessed at different time points during the training period and again on days 1, 3, 10 and 17 after the training. The findings were as follows: (1) steady decline in maximal muscle strength with major recovery within 24 hours after the first six daily training sessions; (2) larger decline in electrically induced muscle torque and prolonged recovery during last three training sessions; (3) increase in patellar and Achilles tendons CSA without change in thickness towards the end of training period; (4) increase in jump height but not in muscle strength after whole training period. Our findings suggest that frequent drop-jump sessions with constant load alternated with rapid increases in load do not induce severe muscle damage or major changes in tendons, nonetheless, this type of loading is not advisable for muscle strength improvement. Key points Frequent drop jump training induces activation mode dependent muscle torque depression late in the training period. No significant changes in the thickness of patellar and Achilles tendons are observed during frequent training, while CSA increases towards the end of training period. Longitudinal effect for jump height but not for muscle strength is evident after the whole training period. PMID:26664280

  11. The Influence of External Load on Quadriceps Muscle and Tendon Dynamics during Jumping.

    PubMed

    Earp, Jacob E; Newton, Robert U; Cormie, Prue; Blazevich, Anthony J

    2017-11-01

    Tendons possess both viscous (rate-dependent) and elastic (rate-independent) properties that determine tendon function. During high-speed movements external loading increases both the magnitude (FT) and rate (RFDT) of tendon loading. The influence of external loading on muscle and tendon dynamics during maximal vertical jumping was explored. Ten resistance-trained men performed parallel-depth, countermovement vertical jumps with and without additional load (0%, 30%, 60%, and 90% of maximum squat lift strength), while joint kinetics and kinematics, quadriceps tendon length (LT) and patellar tendon FT and RFDT were estimated using integrated ultrasound, motion analysis and force platform data and muscle tendon modelling. Estimated FT and RFDT, but not peak LT, increased with external loading. Temporal comparisons between 0% and 90% loads revealed that FT was greater with 90% loading throughout the majority of the movement (11%-81% and 87%-95% movement duration). However, RFDT was greater with 90% load only during the early movement initiation phase (8%-15% movement duration) but was greater in the 0% load condition later in the eccentric phase (27%-38% movement duration). LT was longer during the early movement (12%-23% movement duration) but shorter in the late eccentric and early concentric phases (48%-55% movement duration) with 90% load. External loading positively influenced peak FT and RFDT but tendon strain appeared unaffected, suggesting no additive effect of external loading on patellar tendon lengthening during human jumping. Temporal analysis revealed that external loading resulted in a large initial RFDT that may have caused dynamic stiffening of the tendon and attenuated tendon strain throughout the movement. These results suggest that external loading influences tendon lengthening in both a load- and movement-dependent manner.

  12. The effect of in situ freezing on rabbit patellar tendon. A histologic, biochemical, and biomechanical analysis

    NASA Technical Reports Server (NTRS)

    Graf, B. K.; Fujisaki, K.; Vanderby, R. Jr; Vailas, A. C.

    1992-01-01

    Cell necrosis has been well documented as one of the many changes that occur in autogenous tendon when it is used to reconstruct the anterior cruciate ligament. The purpose of this experiment was to isolate cell necrosis as a variable and study its effect on the patellar tendon. To accomplish this, both knees of 25 New Zealand White rabbits were operated on. In one knee, a 5-mm wide band of patellar tendon was subjected to two rapid freeze-thaw cycles, while the other knee underwent sham surgery. Histologic evaluation showed a zone of necrosis at 2 and 4 weeks with cellular repopulation complete at 8 weeks. patellar tendon cross-sectional area was 0.118 cm2 at 8 weeks for the frozen specimens compared to 0.102 cm2 for the sham-operated controls. This difference was significant at the P = 0.025 level. Mechanical testing at 4 and 8 weeks revealed no significant changes in tendon length, maximum load, or stiffness. The collagen content was also unchanged at both 4 and 8 weeks.

  13. Tension degradation of anterior cruciate ligament grafts with dynamic flexion-extension loading: a biomechanical model in porcine knees.

    PubMed

    Dargel, Jens; Koebke, Jürgen; Brüggemann, Gert-Peter; Pennig, Dietmar; Schmidt-Wiethoff, Rüdiger

    2009-10-01

    This study investigates the influence of various femoral anterior cruciate ligament graft fixation methods on the amount of tension degradation and the initial fixation strength after cyclic flexion-extension loading in a porcine knee model. One hundred twenty porcine digital extensor tendons, used as 4-stranded free tendon grafts, were fixated within porcine femoral bone tunnels by use of extracortical button, cross-pin, or interference screw fixation. One hundred twenty porcine patellar tendon-bone grafts were fixated by use of cross-pin, interference screw, or press-fit fixation. Each femur-graft complex was submitted to cyclic flexion-extension loading for 1,000 cycles throughout different loading ranges, and the total loss of tension was determined. After cyclic testing, the grafts were loaded to failure, and the data were compared with a pullout series without cyclic loading. Tension degradation after 1,000 cycles of flexion-extension loading averaged 62.6% +/- 10.0% in free tendon grafts and 48.9% +/- 13.35% in patellar tendon-bone grafts. There was no influence of the loading range on the total amount of tension degradation. The total amount of tension degradation was the highest with interference screw fixation of free tendon and patellar tendon-bone grafts. Despite excessive loss of tension, the initial fixation strength of the femur-graft complex was not reduced. The method of femoral graft fixation significantly influenced tension degradation during dynamic flexion-extension loading. Femoral graft fixation methods that secure the graft close to the tunnel entrance and that displace the graft substance from the center of the bone tunnel show the largest amount of tension degradation during cyclic flexion-extension loading. The graft substance, not the fixation site, was the weakest link of the graft complex within this investigation. We believe that the graft fixation method should be considered when aiming to improve the precision of femoral graft placement in anterior cruciate ligament reconstruction.

  14. Angiopoietin‐like 4 promotes angiogenesis in the tendon and is increased in cyclically loaded tendon fibroblasts

    PubMed Central

    Mousavizadeh, Rouhollah; Scott, Alex; Lu, Alex; Ardekani, Gholamreza S; Behzad, Hayedeh; Lundgreen, Kirsten; Ghaffari, Mazyar; McCormack, Robert G

    2016-01-01

    Key points Angiopoietin‐like 4 (ANGPTL4) modulates tendon neovascularization.Cyclic loading stimulates the activity of transforming growth factor‐β and hypoxia‐inducible factor 1α and thereby increases the expression and release of ANGPTL4 from human tendon cells.Targeting ANGPTL4 and its regulatory pathways is a potential avenue for regulating tendon vascularization to improve tendon healing or adaptation. Abstract The mechanisms that regulate angiogenic activity in injured or mechanically loaded tendons are poorly understood. The present study examined the potential role of angiopoietin‐like 4 (ANGPTL4) in the angiogenic response of tendons subjected to repetitive mechanical loading or injury. Cyclic stretching of human tendon fibroblasts stimulated the expression and release of ANGPTL4 protein via transforming growth factor‐β (TGF‐β) and hypoxia‐inducible factor 1α (HIF‐1α) signalling, and the released ANGPTL4 was pro‐angiogenic. Angiogenic activity was increased following ANGPTL4 injection into mouse patellar tendons, whereas the patellar tendons of ANGPTL4 knockout mice displayed reduced angiogenesis following injury. In human rotator cuff tendons, the expression of ANGPTL4 was correlated with the density of tendon endothelial cells. To our knowledge, this is the first study characterizing a role of ANGPTL4 in the tendon. ANGPTL4 may assist in the regulation of vascularity in the injured or mechanically loaded tendon. TGF‐β and HIF‐1α comprise two signalling pathways that modulate the expression of ANGPTL4 by mechanically stimulated tendon fibroblasts and, in the future, these could be manipulated to influence tendon healing or adaptation. PMID:26670924

  15. Medial Patellofemoral Ligament Reconstruction Procedure Using a Suspensory Femoral Fixation System

    PubMed Central

    Nakagawa, Shuji; Arai, Yuji; Kan, Hiroyuki; Ueshima, Keiichiro; Ikoma, Kazuya; Terauchi, Ryu; Kubo, Toshikazu

    2013-01-01

    Recurrent patellar dislocation has recently been treated with anatomic medial patellofemoral ligament (MPFL) reconstruction using a semitendinosus muscle tendon. Although it is necessary to add tension to fix the tendon graft without loading excess stress on the patellofemoral joint, adjustment of the tension can be difficult. To resolve this problem, we developed an MPFL reconstruction procedure using the ToggleLoc Fixation Device (Biomet, Warsaw, IN), in which the semitendinosus muscle tendon is folded and used as a double-bundle tendon graft and 2 bone tunnels and 1 bone tunnel are made on the patellar and femoral sides, respectively. The patellar side of the tendon graft is fixed with an EndoButton (Smith & Nephew, London, England), and the femoral side is fixed with the ToggleLoc. Stepless adjustment of tension of the tendon graft is possible by reducing the size of the loop of the ToggleLoc hung onto the tendon graft. It may be useful to position the patella in the center of the femoral sulcus by confirming the patellofemoral joint fitting. Stability can be confirmed by loading lateral stress on the patella in the extended knee joint. This procedure is less invasive because opening of the lateral side of the femur is not necessary, and it may be useful for MPFL reconstruction. PMID:24892014

  16. In vitro kinematic measurements of the patellar tendon in two different types of posterior-stabilized total knee arthroplasties.

    PubMed

    Zhu, Zhonglin; Ding, Hui; Dang, Xiao; Tang, Jing; Zhou, Yixin; Wang, Guangzhi

    2010-01-01

    Fixed-bearing posterior-stabilized (PS) total knee arthroplasty (TKA) has been used in Asian countries for several years, but few studies have investigated differences in the kinematic properties of the patellar tendon after standard PS TKA as compared to high-flex PS TKA. To quantify the in vitro three-dimensional (3D) kinematics of the patellar tendon during passive high flexion and full extension before and after two different types of PS TKAs. Six fresh-frozen cadaveric knees were tested under the following conditions: the unaltered state, status-post traditional PS prostheses (Simth-nephew GENESIS II) replacement, and status-post high-flexion PS prostheses replacement. The soft tissue around the knee and the quadriceps muscle were preserved, then tested under the load of a specific weight in an Oxford knee rig. We designed a specialized rigid body with four active markers fixed to each bone to track the 3D passive motion of the cadaveric knees. Flexion and extension was controlled by the knee rig and captured by an Optotrak Certus high precision optical tracking system. The attachment sites of the patellar tendon were registered as virtual markers to calculate the 3D kinematics. The patellar tendon of the unaltered knee and both TKA knees showed similar deformation. We found the length of the patellar tendon changed significantly during a motion from full extension to 30°, but there was no significant change in length while undergoing a motion from 30° to full flexion. Both the sagittal plane and coronal plane angles of the patellar tendon decreased after PS TKAs. There was no significant difference in patellar tendon kinematics between the two types of PS TKAs. We believe the changes observed in the sagittal plane and coronal plane angles of the patellar tendon after PS TKAs may influence the extensor mechanism and be an important cause of patella-femoral complications. These data may be used to assess patella-femoral complications after surgery so as to improve the design of high-flexion TKAs for Asians and achieve long-term stability.

  17. Beta-tricalcium phosphate plugs for press-fit fixation in ACL reconstruction--a mechanical analysis in bovine bone.

    PubMed

    Mayr, Hermann O; Hube, Robert; Bernstein, Anke; Seibt, Alexander B; Hein, Werner; von Eisenhart-Rothe, Ruediger

    2007-06-01

    The goal of this study was to test fixation properties of microporous pure beta-tricalcium phosphate (TCP) plugs (porosity 40%) for press-fit fixation of the ACL graft using patellar tendons with and without bone blocks. We set out to establish whether it is possible, in this way, to obtain results comparable with those of interference screw fixation of bone-tendon-bone (BTB) grafts in terms of cyclic loading and load-to-failure. In a bovine model 30 ACL grafts were fixed in tibial drill holes, divided into three groups: 10 BTB grafts fixed with TCP press-fit plugs (7x25 mm), 10 pure patellar tendon grafts with TCP press-fit plugs (7x25 mm), and 10 BTB grafts with metal interference screws (7x25 mm). All grafts were tested by cyclic loading (50-200 N) and loaded until failure in a tensiometer. Under cyclic loading one interference screw fixation failed. None of the TCP plug fixations failed. After 1500 cycles the displacement of the graft in the drill hole for BTB fixed with screws was 3.6+/-7.8 mm, for BTB/TCP plugs 1.6+/-3.4 mm, and for the pure tendon/TCP grafts 1.4+/-0.4 mm. Regarding cyclic loading the pure tendon/TCP system was significantly superior to BTB (p=0.007). The load-to-failure for the BTB/interference screw group was 908+/-539 N with a stiffness of 94+/-36 N/mm, 936+/-245 N for the BTB/TCP cylinder group with a stiffness of 98+/-12 N/mm, and 673+/-159 N for the pure tendon/TCP group with a stiffness of 117+/-9 N/mm. In terms of pull-out load the BTB/TCP system was significantly better than the pure tendon/TCP group (p=0.011). However, pure tendon/TCP grafts achieved significantly greater stiffness (p=0.002) than the BTB system. Press-fit fixation with microporous pure beta-TCP plugs of BTB grafts or patellar tendon grafts without bone blocks for ACL reconstruction leads to primary stability comparable with that achieved by fixation with metal interference screws in case of BTB grafts.

  18. Biomechanical analysis of the single‐leg decline squat

    PubMed Central

    Zwerver, J; Bredeweg, S W; Hof, A L

    2007-01-01

    Background The single‐leg squat on a 25° decline board has been described as a clinical assessment tool and as a rehabilitation exercise for patients with patellar tendinopathy. Several assumptions have been made about its working mechanism on patellar load and patellofemoral forces, but these are not substantiated by biomechanical evaluations. Aim To investigate knee moment and patellofemoral contact force as a function of decline angle in the single‐leg squat. Methods Five subjects performed single‐leg eccentric squats at decline angles of 0°, 5°, 10°, 15°, 20° and 25° (with/without a backpack of 10 kg), and 30° on a board that was placed over a forceplate. Kinematic and forceplate data were recorded by the Optotrak system. Joint moments of ankle, knee and hip were calculated by two‐dimensional inverse dynamics. Results Knee moment increased by 40% at decline angles of 15° and higher, whereas hip and ankle moment decreased. Maximum knee and ankle angles increased with steeper decline. With a 10 kg backpack at 25° decline, the knee moment was 23% higher than unloaded. Both patellar tendon and patellofemoral forces increased with higher decline angles, but beyond 60°, the patellofemoral force rose steeper than the tendon force. Conclusions All single‐leg squats at decline angles >15° result in 40% increase in maximum patellar tendon force. In knee flexions >60°, patellofemoral forces increase more than patellar tendon forces. Higher tendon load can be achieved by the use of a backpack with extra weight. PMID:17224441

  19. Angiopoietin-like 4 promotes angiogenesis in the tendon and is increased in cyclically loaded tendon fibroblasts.

    PubMed

    Mousavizadeh, Rouhollah; Scott, Alex; Lu, Alex; Ardekani, Gholamreza S; Behzad, Hayedeh; Lundgreen, Kirsten; Ghaffari, Mazyar; McCormack, Robert G; Duronio, Vincent

    2016-06-01

    Angiopoietin-like 4 (ANGPTL4) modulates tendon neovascularization. Cyclic loading stimulates the activity of transforming growth factor-β and hypoxia-inducible factor 1α and thereby increases the expression and release of ANGPTL4 from human tendon cells. Targeting ANGPTL4 and its regulatory pathways is a potential avenue for regulating tendon vascularization to improve tendon healing or adaptation. The mechanisms that regulate angiogenic activity in injured or mechanically loaded tendons are poorly understood. The present study examined the potential role of angiopoietin-like 4 (ANGPTL4) in the angiogenic response of tendons subjected to repetitive mechanical loading or injury. Cyclic stretching of human tendon fibroblasts stimulated the expression and release of ANGPTL4 protein via transforming growth factor-β (TGF-β) and hypoxia-inducible factor 1α (HIF-1α) signalling, and the released ANGPTL4 was pro-angiogenic. Angiogenic activity was increased following ANGPTL4 injection into mouse patellar tendons, whereas the patellar tendons of ANGPTL4 knockout mice displayed reduced angiogenesis following injury. In human rotator cuff tendons, the expression of ANGPTL4 was correlated with the density of tendon endothelial cells. To our knowledge, this is the first study characterizing a role of ANGPTL4 in the tendon. ANGPTL4 may assist in the regulation of vascularity in the injured or mechanically loaded tendon. TGF-β and HIF-1α comprise two signalling pathways that modulate the expression of ANGPTL4 by mechanically stimulated tendon fibroblasts and, in the future, these could be manipulated to influence tendon healing or adaptation. © 2015 The Authors. The Journal of Physiology © 2015 The Physiological Society.

  20. Diabetes Alters Mechanical Properties and Collagen Fiber Re-Alignment in Multiple Mouse Tendons

    PubMed Central

    Connizzo, Brianne K.; Bhatt, Pankti R.; Liechty, Kenneth W.; Soslowsky, Louis J.

    2014-01-01

    Tendons function to transfer load from muscle to bone through their complex composition and hierarchical structure, consisting mainly of type I collagen. Recent evidence suggests that type II diabetes may cause alterations in collagen structure, such as irregular fibril morphology and density, which could play a role in the mechanical function of tendons. Using the db/db mouse model of type II diabetes, the diabetic skin was found to have impaired biomechanical properties when compared to the non-diabetic group. The purpose of this study was to assess the effect of diabetes on biomechanics, collagen fiber re-alignment, and biochemistry in three functionally different tendons (Achilles, supraspinatus, patellar) using the db/db mouse model. Results showed that cross-sectional area and stiffness, but not modulus, were significantly reduced in all three tendons. However, the tendon response to load (transition strain, collagen fiber re-alignment) occurred earlier in the mechanical test, contrary to expectations. In addition, the patellar tendon had an altered response to diabetes when compared to the other two tendons, with no changes in fiber realignment and decreased collagen content at the midsubstance of the tendon. Overall, type II diabetes alters tendon mechanical properties and the dynamic response to load. PMID:24833253

  1. Changes in tendon spatial frequency parameters with loading.

    PubMed

    Pearson, Stephen J; Engel, Aaron J; Bashford, Gregory R

    2017-05-24

    To examine and compare the loading related changes in micro-morphology of the patellar tendon. Fifteen healthy young males (age 19±3yrs, body mass 83±5kg) were utilised in a within subjects matched pairs design. B mode ultrasound images were taken in the sagittal plane of the patellar tendon at rest with the knee at 90° flexion. Repeat images were taken whilst the subjects were carrying out maximal voluntary isometric contractions. Spatial frequency parameters related to the tendon morphology were determined within regions of interest (ROI) from the B mode images at rest and during isometric contractions. A number of spatial parameters were observed to be significantly different between resting and contracted images (Peak spatial frequency radius (PSFR), axis ratio, spatial Q-factor, PSFR amplitude ratio, and the sum). These spatial frequency parameters were indicative of acute alterations in the tendon micro-morphology with loading. Acute loading modifies the micro-morphology of the tendon, as observed via spatial frequency analysis. Further research is warranted to explore its utility with regard to different loading induced micro-morphological alterations, as these could give valuable insight not only to aid strengthening of this tissue but also optimization of recovery from injury and treatment of conditions such as tendinopathies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Effects of habitual loading on patellar tendon mechanical and morphological properties in basketball and volleyball players.

    PubMed

    Zhang, Z J; Ng, G Y F; Fu, S N

    2015-11-01

    Tendon mechanical properties are linked to sports performance and tendon-related injuries, such as tendinopathy. Whether habitual loading, such as participation in regular jumping activities, would induce adaptation on tendon mechanical properties remains unclear. Forty healthy subjects (10 sedentary, 15 volleyball players, and 15 basketball players) aged between 18 and 35 years were recruited. Supersonic shearwave imaging was used to measure the shear elastic modulus and thickness and cross-sectional area (CSA) of the proximal patellar tendons of both knees at 30° of flexion. Significant group differences in tendon shear elastic modulus were found among the three groups. In the dominant leg, reduction in tendon shear elastic modulus by 18.9 % (p = 0.018) and 48.7 % (p = 0.000) were observed in the basketball and volleyball players, respectively, when compared with sedentary subjects. In the non-dominant leg, reduction in tendon shear elastic modulus were 27.3 % (p = 0.034) and 47.1 % (p = 0.02) in the basketball and volleyball players, respectively. The athlete groups were found to have larger CSA but with similar tendon thickness than sedentary group. The CSA were larger by 24-29 % and by 22-24 % in the basketball players and volleyball players, for the dominant and non-dominant legs, respectively (all p < 0.05). Age and body mass are related to tendon stiffness and CSA, particularly in the sedentary subjects. The proximal patellar tendon can undergo substantial adaptation on tendon mechanical and morphological properties when exposed in jumping sports. Intrinsic factors such as age and body mass could influence tendon properties.

  3. Tendon Contraction After Cyclic Elongation Is an Age-Dependent Phenomenon: In Vitro and In Vivo Comparisons.

    PubMed

    Lavagnino, Michael; Bedi, Asheesh; Walsh, Christopher P; Sibilsky Enselman, Elizabeth R; Sheibani-Rad, Shahin; Arnoczky, Steven P

    2014-06-01

    Tendons are viscoelastic tissues that deform (elongate) in response to cyclic loading. However, the ability of a tendon to recover this elongation is unknown. Tendon length significantly increases after in vivo or in vitro cyclic loading, and the ability to return to its original length through a cell-mediated contraction mechanism is an age-dependent phenomenon. Controlled laboratory study. In vitro, rat tail tendon fascicles (RTTfs) from Sprague-Dawley rats of 3 age groups (1, 3, and 12 months) underwent 2% cyclic strain at 0.17 Hz for 2 hours, and the percentages of elongation were determined. After loading, the RTTfs were suspended for 3 days under tissue culture conditions and photographed daily to determine the amount of length contraction. In vivo, healthy male participants (n = 29; age, 19-49 years) had lateral, single-legged weightbearing radiographs taken of the knee at 60° of flexion immediately before, immediately after, and 24 hours after completing eccentric quadriceps loading exercises on the dominant leg to fatigue. Measurements of patellar tendon length were taken from the radiographs, and the percentages of tendon elongation and subsequent contraction were calculated. In vitro, cyclic loading increased the length of all RTTfs, with specimens from younger (1 and 3 months) rats demonstrating significantly greater elongation than those from older (12 months) rats (P = .009). The RTTfs contracted to their original length significantly faster (P < .001) and in an age-dependent fashion, with younger animals contracting faster. In vivo, repetitive eccentric loading exercises significantly increased patellar tendon length (P < .001). Patellar tendon length decreased 24 hours after exercises (P < .001) but did not recover completely (P < .001). There was a weak but significant (R (2) = 0.203, P = .014) linear correlation between the amount of tendon contraction and age, with younger participants (<30 years) demonstrating significantly more contraction (P = .014) at 24 hours than older participants (>30 years). Cyclic tendon loading results in a significant increase in tendon elongation under both in vitro and in vivo conditions. Tendons in both conditions demonstrated an incomplete return to their original length after 24 hours, and the extent of this return was age dependent. The age- and time-dependent contraction of tendons, elongated after repetitive loading, could result in transient alterations in the mechanobiological environment of tendon cells. This, in turn, could induce the onset of catabolic changes associated with the pathogenesis of tendinopathy. These results suggest the importance of allowing time for contraction between bouts of repetitive exercise and may explain why age is a predisposing factor in tendinopathy. © 2014 The Author(s).

  4. Patellar tendon re-rupture on the opposite end of the previous site of surgical repair

    PubMed Central

    KOH, Bryan Thean Howe; SAYAMPANATHAN, Andrew A; LEE, Keng Thiam

    2017-01-01

    We describe a rare case of a patellar tendon “re-rupture” at the opposite end of a previous proximal tendon repair. A 32-year-old male with a history of surgically repaired right proximal patellar tendon rupture presented with an acute non-traumatic right knee pain and instability during sports. Magnetic resonance imaging confirmed a complete rupture of his distal patellar tendon at the tibial tuberosity. The patellar tendon was repaired using two 5.5 mm BioCorkscrews (Arthrex) inserted into the tibial tuberosity; the tendon was stitched with the No. 2 fiberwires using Krackow technique. As the patellar tendon was degenerative, the repair was augmented with a semitendinosus tendon harvested using an open tendon stripper, leaving the distal attachment intact. At 2.6 years followup he had mild anterior knee pain, range of motion 0-130° and was able to squat. MRI scan done at followup revealed good healing of repaired patellar tendon. PMID:28566788

  5. Biomechanical characterization of double-bundle femoral press-fit fixation techniques.

    PubMed

    Ettinger, M; Haasper, C; Hankemeier, S; Hurschler, C; Breitmeier, D; Krettek, C; Jagodzinski, M

    2011-03-01

    Press-fit fixation of patellar tendon bone anterior cruciate ligament autografts is an interesting technique because no hardware is necessary. To date, no biomechanical data exist describing an implant-free double-bundle press-fit procedure. The purpose of this study was to characterize the biomechanical properties of three double-bundle press-fit fixations. In a controlled laboratory study, the patellar-, quadriceps- and hamstring tendons of 10 human cadavers (age: 49.2 ± 18.5 years) were used. An inside out press-fit fixation with a knot in the semitendinosus and gracilis tendons (SG) combined with an additional bone block, with two quadriceps tendon bone block grafts (QU) was compared with press-fit fixation of two bone patellar tendon bone block (PT) grafts in 30 porcine femora. Constructs were cyclically stretched and then loaded until failure. Maximum load to failure, stiffness and elongation during failure testing and cyclical loading were investigated. The maximum load to failure was 703 ± 136 N for SG fixation, 632 ± 130 N for QU and 656 ± 127 N for PT fixation. Stiffness of the constructs averaged 138 ± 26 N/mm for SG, 159 ± 74 N/mm for QU, and 154 ± 50 N/mm for PT fixation. Elongation during initial cyclical loading was 1.2 ± 1.4 mm for SG, 2.0 ± 1.4 mm for QU, and 1.0 ± 0.6 mm for PT (significantly larger for PT and QU between the first 5 cycles compared with cycles 15-20th, P < 0.01). All investigated double-bundle fixation techniques were equal in terms of maximum load to failure, stiffness, and elongation. Unlike with single-bundle press-fit fixation techniques that have been published, no difference was observed between pure tendon combined with an additional bone block and tendon bone grafts. All techniques exhibited larger elongation during initial cyclical loading. All three press-fit fixation techniques that were investigated exhibit comparable biomechanical properties. Preconditioning of the constructs is critical.

  6. Novel Augmentation Technique for Patellar Tendon Repair Improves Strength and Decreases Gap Formation: A Cadaveric Study.

    PubMed

    Black, James C; Ricci, William M; Gardner, Michael J; McAndrew, Christopher M; Agarwalla, Avinesh; Wojahn, Robert D; Abar, Orchid; Tang, Simon Y

    2016-12-01

    Patellar tendon ruptures commonly are repaired using transosseous patellar drill tunnels with modified-Krackow sutures in the patellar tendon. This simple suture technique has been associated with failure rates and poor clinical outcomes in a modest proportion of patients. Failure of this repair technique can result from gap formation during loading or a single catastrophic event. Several augmentation techniques have been described to improve the integrity of the repair, but standardized biomechanical evaluation of repair strength among different techniques is lacking. The purpose of this study was to describe a novel figure-of-eight suture technique to augment traditional fixation and evaluate its biomechanical performance. We hypothesized that the augmentation technique would (1) reduce gap formation during cyclic loading and (2) increase the maximum load to failure. Ten pairs (two male, eight female) of fresh-frozen cadaveric knees free of overt disorders or patellar tendon damage were used (average donor age, 76 years; range, 65-87 years). For each pair, one specimen underwent the standard transosseous tunnel suture repair with a modified-Krackow suture technique and the second underwent the standard repair with our experimental augmentation method. Nine pairs were suitable for testing. Each specimen underwent cyclic loading while continuously measuring gap formation across the repair. At the completion of cyclic loading, load to failure testing was performed. A difference in gap formation and mean load to failure was seen in favor of the augmentation technique. At 250 cycles, a 68% increase in gap formation was seen for the control group (control: 5.96 ± 0.86 mm [95% CI, 5.30-6.62 mm]; augmentation: 3.55 ± 0.56 mm [95% CI, 3.12-3.98 mm]; p = 0.02). The mean load to failure was 13% greater in the augmentation group (control: 899.57 ± 96.94 N [95% CI, 825.06-974.09 N]; augmentation: 1030.70 ± 122.41 N [95% CI, 936.61-1124.79 N]; p = 0.01). This biomechanical study showed improved performance of a novel augmentation technique compared with the standard repair, in terms of reduced gap formation during cyclic loading and increased maximum load to failure. Decreased gap formation and higher load to failure may improve healing potential and minimize failure risk. This study shows a potential biomechanical advantage of the augmentation technique, providing support for future clinical investigations comparing this technique with other repair methods that are in common use such as transosseous suture repair.

  7. Bilateral Patellar Tendon Rupture

    DTIC Science & Technology

    2009-07-01

    Bilateral patellar tendon rupture Military Medicine Radiology Corner, Volume 173, July, 2009...Radiology Corner Bilateral patellar tendon rupture (#37) Guarantor: 2dLt Ramon A. Riojas, USAF, MSC1 Contributors: 2dLt Ramon A. Riojas...with the abbreviated answer in the July 2009 issue. 1 The authors present a case of bilateral patellar tendon rupture in an active duty male exiting

  8. Tibial Inlay Press-fit Fixation Versus Interference Screw in Posterior Cruciate Ligament Reconstruction.

    PubMed

    Ettinger, Max; Büermann, Sarah; Calliess, Tilman; Omar, Mohamed; Krettek, Christian; Hurschler, Christof; Jagodzinski, Michael; Petri, Maximilian

    2013-01-01

    Reconstruction of the posterior cruciate ligament (PCL) by a tibial press-fit fixation of the patellar tendon with an accessory bone plug is a promising approach because no foreign materials are required. Until today, there is no data about the biomechanical properties of such press-fit fixations. The aim of this study was to compare the biomechanical qualities of a bone plug tibial inlay technique with the commonly applied interference screw of patellar tendon PCL grafts. Twenty patellar tendons including a bone block were harvested from ten human cadavers. The grafts were implanted into twenty legs of adult German country pigs. In group P, the grafts were attached in a press-fit technique with accessory bone plug. In group S, the grafts were fixed with an interference screw. Each group consisted of 10 specimens. The constructs were biomechanically analyzed in cyclic loading between 60 and 250 N for 500 cycles recording elongation. Finally, ultimate failure load and failure mode were analyzed. Ultimate failure load was 598.6±36.3 N in group P and 653.7±39.8 N in group S (not significant, P>0.05). Elongation during cyclic loading between the 1(st) and the 20(th) cycle was 3.4±0.9 mm for group P and 3.1±1 mm for group S. Between the 20(th) and the 500(th) cycle, elongation was 4.2±2.3 mm in group P and 2.5±0.9 mm in group S (not significant, P>0.05). This is the first study investigating the biomechanical properties of tibial press-fit fixation of the patellar tendon with accessory bone plug in posterior cruciate ligament reconstruction. The implant-free tibial inlay technique shows equal biomechanical characteristics compared to an interference screw fixation. Further in vivo studies are desirable to compare the biological behavior and clinical relevance of this fixation device.

  9. Greater glycosaminoglycan content in human patellar tendon biopsies is associated with more pain and a lower VISA score.

    PubMed

    Attia, Mohamed; Scott, Alexander; Carpentier, Gilles; Lian, Oystein; Van Kuppevelt, Toin; Gossard, Camille; Papy-Garcia, Dulce; Tassoni, Marie-Claude; Martelly, Isabelle

    2014-03-01

    People with patellar tendinopathy experience chronic pain and activity limitation, but a pertinent biochemical marker correlated with these clinical features has not been identified. The Victoria Institute of Sport Assessment (VISA) questionnaire is a condition-specific patient-rated outcome measure. Since the quantity of glycosaminoglycans (GAGs) increases with advancing tendon pathology, we hypothesised that there would be a correlation between the quantity of GAGs in the patellar tendon and the VISA score. Tissue biopsies from athletes with chronic patellar tendinopathy (confirmed by clinical examination and MRI) were recruited (n=7), as well as controls with no history of knee pain (n=4). The quantity of sulphated GAGs in the human patellar tendons was determined with a dimethyl methylene blue (DMMB) assay; this method was first validated with rat tendon tissue. The extent and distribution of GAG species and proteoglycans (decorin, versican and aggrecan) in the human tendon biopsies were examined using immunohistochemistry. Greater sulphated GAG content of the patellar tendon was correlated with the greater tendon dysfunction (R(2)=0.798). The quantity of aggrecan in the tendon, a chondroitin sulphate-rich proteoglycan, also increased with advancing tendon pathology. Increased GAGs in the pathological human patellar tendon are related to a worse clinical status. These findings indicate that the VISA score reflects the extent of tendon tissue pathology.

  10. Patellar tendon healing with platelet-rich plasma: a prospective randomized controlled trial.

    PubMed

    de Almeida, Adriano Marques; Demange, Marco Kawamura; Sobrado, Marcel Faraco; Rodrigues, Marcelo Bordalo; Pedrinelli, André; Hernandez, Arnaldo José

    2012-06-01

    The patellar tendon has limited ability to heal after harvesting its central third. Platelet-rich plasma (PRP) could improve patellar tendon healing. Adding PRP to the patellar tendon harvest site would improve donor site healing and improve clinical outcome at 6 months after anterior cruciate ligament (ACL) reconstruction with a patellar tendon graft. Randomized controlled trial; Level of evidence, 1. Twenty-seven patients were randomly divided to receive (n = 12) or not receive (n = 15) PRP in the patellar tendon harvest site during ACL reconstruction. The primary outcome was magnetic resonance imaging (MRI) assessment of patellar tendon healing (gap area) after 6 months. Secondary outcomes were questionnaires and isokinetic testing of ACL reconstruction with a patellar tendon graft comparing both groups. Patellar tendon gap area was significantly smaller in the PRP group (4.9 ± 5.3 mm(2); 95% confidence interval [CI], 1.1-8.8) than in the control group (9.4 ± 4.4 mm(2); 95% CI, 6.6-12.2; P = .046). Visual analog scale score for pain was lower in the PRP group immediately postoperatively (3.8 ± 1.0; 95% CI, 3.18-4.49) than in the control group (5.1 ± 1.4; 95% CI, 4.24-5.90; P = .02). There were no differences after 6 months in questionnaire and isokinetic testing results comparing both groups. We showed that PRP had a positive effect on patellar tendon harvest site healing on MRI after 6 months and also reduced pain in the immediate postoperative period. Questionnaire and isokinetic testing results were not different between the groups at 6 months.

  11. Re-revision of a patellar tendon rupture in a young professional martial arts athlete.

    PubMed

    Vadalà, A; Iorio, R; Bonifazi, A M; Bolle, G; Ferretti, A

    2012-09-01

    A 27-year-old professional martial arts athlete experienced recurrent right knee patellar tendon rupture on three occasions. He underwent two operations for complete patellar tendon rupture: an end-to-end tenorrhaphy the first time, and revision with a bone-patellar-tendon (BPT) allograft. After the third episode, he was referred to our department, where we performed a surgical reconstruction with the use of hamstring pro-patellar tendon, in a figure-of-eight configuration, followed by a careful rehabilitation protocol. Clinical and radiological follow-ups were realized at 1, 3, and 6 months and 1 and 2 years postop, with an accurate physical examination, the use of recognized international outcome scores, and radiograph and MRI studies. As far as we know, this is the first paper to report a re-revision of a patellar tendon rupture.

  12. Differences in tendon properties in elite badminton players with or without patellar tendinopathy.

    PubMed

    Couppé, C; Kongsgaard, M; Aagaard, P; Vinther, A; Boesen, M; Kjaer, M; Magnusson, S P

    2013-03-01

    The aim of this study was to examine the structural and mechanical properties of the patellar tendon in elite male badminton players with and without patellar tendinopathy. Seven players with unilateral patellar tendinopathy (PT group) on the lead extremity (used for forward lunge) and nine players with no current or previous patellar tendinopathy (CT group) were included. Magnetic resonance imaging was used to assess distal patellar tendon dimensions. Patellar tendon mechanical properties were assessed using simultaneous tendon force and deformation measurements. Distal tendon cross-sectional area (CSA) normalized for body weight (mm(2) /kg(2/3) ) was lower in the PT group compared with the CT group on both the non-lead extremity (6.1 ± 0.3 vs 7.4 ± 0.2, P < 0.05) and the lead extremity (6.5 ± 0.6 vs 8.4 ± 0.3, P < 0.05). Distal tendon stress was higher in the PT group compared with the CT group for both the non-lead extremity (31 ± 1 vs 27 ± 1 MPa, P < 0.05) and the lead extremity (32 ± 3 vs 21 ± 3 MPa, P < 0.01). Conclusively, the PT group had smaller distal patellar tendon CSA on both the injured (lead extremity) and the uninjured side (non-lead extremity) compared with the CT group. Subsequently, the smaller CSA yielded a greater distal patellar tendon stress in the PT group. Therefore, a small tendon CSA may predispose to the development of tendinopathy. © 2012 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.

  13. Validation of predicted patellofemoral mechanics in a finite element model of the healthy and cruciate-deficient knee.

    PubMed

    Ali, Azhar A; Shalhoub, Sami S; Cyr, Adam J; Fitzpatrick, Clare K; Maletsky, Lorin P; Rullkoetter, Paul J; Shelburne, Kevin B

    2016-01-25

    Healthy patellofemoral (PF) joint mechanics are critical to optimal function of the knee joint. Patellar maltracking may lead to large joint reaction loads and high stresses on the articular cartilage, increasing the risk of cartilage wear and the onset of osteoarthritis. While the mechanical sources of PF joint dysfunction are not well understood, links have been established between PF tracking and abnormal kinematics of the tibiofemoral (TF) joint, specifically following cruciate ligament injury and repair. The objective of this study was to create a validated finite element (FE) representation of the PF joint in order to predict PF kinematics and quadriceps force across healthy and pathological specimens. Measurements from a series of dynamic in-vitro cadaveric experiments were used to develop finite element models of the knee for three specimens. Specimens were loaded under intact, ACL-resected and both ACL and PCL-resected conditions. Finite element models of each specimen were constructed and calibrated to the outputs of the intact knee condition, and subsequently used to predict PF kinematics, contact mechanics, quadriceps force, patellar tendon moment arm and patellar tendon angle of the cruciate resected conditions. Model results for the intact and cruciate resected trials successfully matched experimental kinematics (avg. RMSE 4.0°, 3.1mm) and peak quadriceps forces (avg. difference 5.6%). Cruciate resections demonstrated either increased patellar tendon loads or increased joint reaction forces. The current study advances the standard for evaluation of PF mechanics through direct validation of cruciate-resected conditions including specimen-specific representations of PF anatomy. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Evaluating Changes in Tendon Crimp with Fatigue Loading as an ex vivo Structural Assessment of Tendon Damage

    PubMed Central

    Freedman, Benjamin R.; Zuskov, Andrey; Sarver, Joseph J.; Buckley, Mark R.; Soslowsky, Louis J.

    2015-01-01

    The complex structure of tendons relates to their mechanical properties. Previous research has associated the waviness of collagen fibers (crimp) during quasi-static tensile loading to tensile mechanics, but less is known about the role of fatigue loading on crimp properties. In this study (IACUC approved), mouse patellar tendons were fatigue loaded while an integrated plane polariscope simultaneously assessed crimp properties. We demonstrate a novel structural mechanism whereby tendon crimp amplitude and frequency are altered with fatigue loading. In particular, fatigue loading increased the crimp amplitude across the tendon width and length, and these structural alterations were shown to be both region and load dependent. The change in crimp amplitude was strongly correlated to mechanical tissue laxity (defined as the ratio of displacement and gauge length relative to the first cycle of fatigue loading assessed at constant load throughout testing), at all loads and regions evaluated. Together, this study highlights the role of fatigue loading on tendon crimp properties as a function of load applied and region evaluated, and offers an additional structural mechanism for mechanical alterations that may lead to ultimate tendon failure. PMID:25773654

  15. The Effects of Mechanical Loading on Tendons - An In Vivo and In Vitro Model Study

    PubMed Central

    Zhang, Jianying; Wang, James H-C.

    2013-01-01

    Mechanical loading constantly acts on tendons, and a better understanding of its effects on the tendons is essential to gain more insights into tendon patho-physiology. This study aims to investigate tendon mechanobiological responses through the use of mouse treadmill running as an in vivo model and mechanical stretching of tendon cells as an in vitro model. In the in vivo study, mice underwent moderate treadmill running (MTR) and intensive treadmill running (ITR) regimens. Treadmill running elevated the expression of mechanical growth factors (MGF) and enhanced the proliferative potential of tendon stem cells (TSCs) in both patellar and Achilles tendons. In both tendons, MTR upregulated tenocyte-related genes: collagen type I (Coll. I ∼10 fold) and tenomodulin (∼3–4 fold), but did not affect non-tenocyte-related genes: LPL (adipocyte), Sox9 (chondrocyte), Runx2 and Osterix (both osteocyte). However, ITR upregulated both tenocyte (Coll. I ∼7–11 fold; tenomodulin ∼4–5 fold) and non-tenocyte-related genes (∼3–8 fold). In the in vitro study, TSCs and tenocytes were stretched to 4% and 8% using a custom made mechanical loading system. Low mechanical stretching (4%) of TSCs from both patellar and Achilles tendons increased the expression of only the tenocyte-related genes (Coll. I ∼5–6 fold; tenomodulin ∼6–13 fold), but high mechanical stretching (8%) increased the expression of both tenocyte (Coll. I ∼28–50 fold; tenomodulin ∼14–48 fold) and non-tenocyte-related genes (2–5-fold). However, in tenocytes, non-tenocyte related gene expression was not altered by the application of either low or high mechanical stretching. These findings indicate that appropriate mechanical loading could be beneficial to tendons because of their potential to induce anabolic changes in tendon cells. However, while excessive mechanical loading caused anabolic changes in tendons, it also induced differentiation of TSCs into non-tenocytes, which may lead to the development of degenerative tendinopathy frequently seen in clinical settings. PMID:23977130

  16. Hamstring tendon versus patellar tendon anterior cruciate ligament reconstruction using biodegradable interference fit fixation: a prospective matched-group analysis.

    PubMed

    Wagner, Michael; Kääb, Max J; Schallock, Jessica; Haas, Norbert P; Weiler, Andreas

    2005-09-01

    There are still controversies about graft selection for primary anterior cruciate ligament reconstruction, especially with respect to knee stability and functional outcome. Biodegradable interference screw fixation of hamstring tendon grafts provides clinical results similar to those achieved with identical fixation of bone-patellar tendon-bone grafts. Cohort study; Level of evidence, 2. In 1996 and 1997, primary isolated anterior cruciate ligament reconstruction using a bone-patellar tendon-bone autograft was performed in 72 patients. Since 1998, hamstring tendons were used as routine grafts. Matched patients with a hamstring tendon graft were selected from a database (n = 284). All patients were followed prospectively for a minimum of 2 years with KT-1000 arthrometer testing, International Knee Documentation Committee score, and Lysholm score. In the bone-patellar tendon-bone group, 9 patients were excluded because of bilateral rupture of the anterior cruciate ligament, 3 patients (4.2%) had a graft rupture, and 4 patients were lost to follow-up (follow-up rate, 92.1%), leaving 56 patients for a matched-group analysis. In the hamstring tendon database, the graft rupture rate was 5.6% (P = .698). The Lysholm score was 89.7 in the patellar tendon group and 94 in the hamstring tendon group (P = .003). The KT-1000 arthrometer side-to-side difference was 2.6 mm for the patellar tendon group and 2.1 mm for the hamstring tendon group (P = .041). There were significantly less positive pivot-shift test results in the hamstring tendon group (P = .005), and hamstring tendon patients showed lower thigh atrophy (P = .024) and patellofemoral crepitus (P = .003). Overall International Knee Documentation Committee scores were better (P = .001) in the hamstring tendon group (hamstring tendon: 34 x A, 21 x B, 0 x C, 0 x D; bone-patellar tendon-bone: 17 x A, 32 x B, 6 x C, 0 x D). In this comparison of anterior cruciate ligament reconstruction with bone-patellar tendon-bone and anatomical hamstring tendon grafts, the hamstring tendon graft was superior in knee stability and function. These findings are partially contrary to previous studies and might be attributable to the use of an anatomical joint line fixation for hamstring tendon grafts. Thus, hamstring tendons are the authors' primary graft choice for anterior cruciate ligament reconstruction, even in high-level athletes.

  17. Reconstruction of a ruptured patellar tendon using ipsilateral semitendinosus and gracilis tendons with preserved distal insertions: two case reports

    PubMed Central

    2013-01-01

    Background Acute patellar tendon ruptures with poor tissue quality. Ruptures that have been neglected are difficult to repair. Several surgical techniques for the repair of the patellar tendon have been reported, however, these techniques remain difficult because of contractures, adhesions, and atrophy of the quadriceps muscle after surgery. Case presentation We report the cases of 2 Japanese patients (Case 1: a 16-year-old male and Case 2: a 43-year-old male) with patellar tendon ruptures who were treated by reconstruction using semitendinosus-gracilis (STG) tendons with preserved distal insertions. Retaining the original insertion of the STG appears to preserve its viability and provide the revascularization necessary to accelerate healing. Both tendons were placed in front of the patella, in a figure-of-eight fashion, providing stability to the patella. Conclusion Both patients recovered near normal strength and stability of the patellar tendon as well as restoration of function after the operation. PMID:24010848

  18. [Neglected ipsilateral simultaneous ruptures of patellar and quadriceps tendon].

    PubMed

    Karahasanoğlu, İlker; Yoloğlu, Osman; Kerimoğlu, Servet; Turhan, Ahmet Uğur

    2015-01-01

    Neglected patellar and quadriceps tendon rupture is a rare injury, but ipsilateral simultaneous patellar and quadriceps tendon rupture was not described in the literature to our knowledge. In this article, we report a 40-year-old healthy male patient with neglected ipsilateral patellar and quadriceps tendon ruptures treated by peroneus longus tendon autograft. Patient had received some conservative and surgical treatments for patellar fracture before applying to our clinic. After our treatment using peroneus longus autograft and interference nails, patient was immobilized for six weeks in cylindrical cast. Flexion exercises and full weight bearing were started after cast removal. Patient had no complaint at postoperative second year. Patient was a neglected case. Surgical repair and early rehabilitation enabled us to achieve a satisfactory outcome.

  19. Synergistic promoting effects of bone morphogenetic protein 12/connective tissue growth factor on functional differentiation of tendon derived stem cells and patellar tendon window defect regeneration.

    PubMed

    Xu, Kang; Sun, Yanjun; Kh Al-Ani, Mohanad; Wang, Chunli; Sha, Yongqiang; Sung, Kl Paul; Dong, Nianguo; Qiu, Xuefeng; Yang, Li

    2018-01-03

    Current study investigated bone morphogenetic protein 12 (BMP12) and connective tissue growth factor (CTGF) activate tendon derived stem cells (TDSCs) tenogenic differentiation, and promotion of injured tendon regeneration. TDSCs were transfected with BMP12 and CTGF via recombinant adenovirus (Ad) infection. Gene transfection efficiency, cell viability and cytotoxicity, tenogenic gene expression, collagen I/III synthesis were evaluated in vitro. For the in vivo study, the transfected cells were transplanted into the rat patellar tendon window defect. At weeks 2 and 8 of post-surgery, the repaired tendon tissues were harvested for histological and biomechanical examinations. The transfected TDSCs revealed relatively stable transfection efficiency (80-90%) with active cell viability means while rare cytotoxicity in each group. During days 1 and 5, BMP12 and CTGF transfection caused tenogenic differentiation genes activation in TDSCs: type I/III collagen, tenascin-C, and scleraxis were all up-regulated, whereas osteogenic, adipogenic, and chondrogenic markers were all down-regulated respectively. In addition, BMP12 and CTGF overexpression significantly promote type I/III collagen synthesis. After in vivo transplantation, at 2 and 8 weeks post-surgery, BMP12, CTGF and co-transfection groups showed more integrated tendon tissue structure versus control, meanwhile, the ultimate failure loads and Young's were all higher than control. Remarkably, at 8 weeks post-surgery, the biomechanical properties of co-transfection group was approaching to normal rat patellar tendon, moreover, the ratio of type III/I collagen maintained about 20% in each transfection group, meanwhile, the type I collagen were significantly increased with co-transfection treatment. In conclusion, BMP12 and CTGF transfection stimulate tenogenic differentiation of TDSCs. The synergistic effects of simultaneous transfection of both may significantly promoted rat patellar tendon window defect regeneration. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Prophylactic training in asymptomatic soccer players with ultrasonographic abnormalities in Achilles and patellar tendons: the Danish Super League Study.

    PubMed

    Fredberg, Ulrich; Bolvig, Lars; Andersen, Niels T

    2008-03-01

    A recent study published in The American Journal of Sports Medicine showed that asymptomatic soccer players with an increased risk of developing Achilles and patellar tendon injuries within the next 12 months can be identified with use of ultrasonography. Prophylactic eccentric training and stretching can reduce both the frequency of asymptomatic ultrasonographic changes in Achilles and patellar tendons in soccer players and the risk of these asymptomatic intratendinous changes becoming symptomatic. Randomized controlled trial; Level of evidence, 1. Two hundred and nine Danish professional soccer players from the best national league (Super League) were followed over 12 months with use of ultrasonography and injury registration. Half the teams were randomized to an intervention group with prophylactic eccentric training and stretching of the Achilles and patellar tendons during the soccer season. The eccentric training and stretching did not reduce the injury risk, and, contrary to all expectations, the injury risk during the season was increased in players with abnormal patellar tendons at the beginning of the study in January. Eccentric training and stretching in players with normal patellar tendons significantly reduced the proportion of players with ultrasonographic changes in the patellar tendons at the end of the season (risk difference [RD] = 12%; 95% confidence interval [CI], 2%-22%; P = .02), but the training had no effect on the Achilles tendons (RD = 1%; 95% CI, -7% to 9%; P = .75). The presence of preseason ultrasonographic abnormalities in the tendons significantly increased the risk of developing tendon symptoms during the season (relative risk = 1.9; 95% CI, 1.2-3.1; P = .009). This study demonstrates that with the use of ultrasonography, tendon changes in soccer players can be diagnosed before they become symptomatic. The prophylactic eccentric training and stretching program reduces the risk of developing ultrasonographic abnormalities in the patellar tendons but has no positive effects on the risk of injury. On the contrary, in asymptomatic players with ultrasonographically abnormal patellar tendons, prophylactic eccentric training and stretching increased the injury risk.

  1. A magnetic resonance imaging study of abnormalities of the patella and patellar tendon that predispose children to acute patellofemoral dislocation.

    PubMed

    Yılmaz, Barış; Çiçek, Esin Derin; Şirin, Evrim; Özdemir, Güzelali; Karakuş, Özgün; Muratlı, Hasan Hilmi

    This study compared 20 children hospitalised with acute patellofemoral dislocation with an age-matched healthy control group with no history of knee problems or patellar dislocation. The following morphological parameters were significantly different between the groups: the mean patellar width and length, mean sulcus depth, mean patellar tendon width and total patellar volume. The magnetic resonance imaging findings of this study suggested that structurally smaller than normal patella and patellar tendon volumes are predisposing factors for acute patellofemoral dislocation. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Neovascularity in patellar tendinopathy and the response to eccentric training: a case report using Power Doppler ultrasound.

    PubMed

    McCreesh, Karen M; Riley, Sara J; Crotty, James M

    2013-12-01

    This report describes the case of an amateur soccer player with chronic patellar tendinopathy who underwent ultrasound imaging before and after engaging in an 8-week programme of eccentric exercise. On initial assessment, greyscale ultrasound imaging demonstrated tendon thickening and reduced echogenicity, while Power Doppler imaging demonstrated a large amount of neovascularity. After 8 weeks of an eccentric loading programme, the patient reported significantly improved symptoms and functional scores, while follow-up imaging demonstrated improvement in the echo appearance of the tendon and complete resolution of the neovascularity. The association between neovascularity and symptoms in tendinopathy research is conflicting, with a paucity of research in the area of patellar tendinopathy. While further research is needed to clarify the significance of greyscale and Power Doppler ultrasound changes in relation to symptoms in patellar tendinopathy, ultrasound imaging was shown to be a useful adjunct to diagnosis and outcome assessment in this case. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. Surgical Treatment for Failure of Repair of Patellar and Quadriceps Tendon Rupture With Ipsilateral Hamstring Tendon Graft.

    PubMed

    Maffulli, Nicola; Papalia, Rocco; Torre, Guglielmo; Denaro, Vincenzo

    2017-03-01

    Tears of the patellar and quadriceps tendon are common in the active population, especially in athletes. At present, several techniques for surgical repair and reconstruction are available. When reruptures occur, a reconstruction is mandatory. In the present paper, we describe a surgical technique for patellar and quadriceps tendon reconstruction using ipsilateral hamstring autograft. After routine hamstring tendon harvesting, the tendon ends are prepared using a whip stitch. A transverse tunnel is drilled in the midportion of the patella, the hamstring graft is passed through the patella, and firmly secured to the patellar tunnel openings with sutures. The details of the technique are fully described. Autologous ipsilateral hamstring tendon grafts provide a secure sound means to manage these challenging injuries.

  4. The prevalence and clinical significance of sonographic tendon abnormalities in asymptomatic ballet dancers: a 24-month longitudinal study.

    PubMed

    Comin, Jules; Cook, Jill L; Malliaras, Peter; McCormack, Moira; Calleja, Michelle; Clarke, Andrew; Connell, David

    2013-01-01

    Sonographic abnormalities of the achilles and patellar tendons are common findings in athletes, and tendinopathy is a common cause of pain and disability in athletes. However, it is unclear whether the sonographic changes are pathological or adaptive, or if they predict future injury. We undertook a cohort study to determine what sonographic features of the achilles and patellar tendons are consistent with changes as a result of ballet training, and which may be predictive of future development of disabling tendon symptoms. The achilles and patellar tendons of 79 (35 male, 44 female) professional ballet dancers (members of the English Royal Ballet) were examined with ultrasound, measuring proximal and distal tendon diameters and assessing for the presence of hypoechoic change, intratendon defects, calcification and neovascularity. All subjects were followed for 24 months for the development of patellar tendon or achilles-related pain or injury severe enough to require time off from dancing. Sonographic abnormalities were common among dancers, both male and female, and in both achilles and patellar tendons. Disabling tendon-related symptoms developed in 10 dancers and 14 tendons: 7 achilles (3 right, 4 left) and 7 patellar (2 right, 5 left). The presence of moderate or severe hypoechoic defects was weakly predictive for the development of future disabling tendon symptoms (p=0.0381); there was no correlation between any of the other sonographic abnormalities and the development of symptoms. There was no relationship between achilles or patellar tendons' diameter, either proximal or distal, with an increased likelihood of developing tendon-related disability. The presence of sonographic abnormalities is common in ballet dancers, but only the presence of focal hypoechoic changes predicts the development of future tendon-related disability. This suggests that screening of asymptomatic individuals may be of use in identifying those who are at higher risk of developing tendon-related disability, which may in turn allow targeted modifications of training or other preventative regimens.

  5. The effect of different decline angles on the biomechanics of double limb squats and the implications to clinical and training practice.

    PubMed

    Richards, Jim; Selfe, James; Sinclair, Jonathan; May, Karen; Thomas, Gavin

    2016-09-01

    Bilateral decline squatting has been well documented as a rehabilitation exercise, however, little information exists on the optimum angle of decline. The aim of this study was to determine the ankle and knee angle, moments, the patellofemoral joint load, patellar tendon load and associated muscle activity while performing a double limb squat at different decline angles and the implications to rehabilitation. Eighteen healthy subjects performed double limb squats at 6 angles of declination: 0, 5, 10, 15, 20 and 25 degrees. The range of motion of the knee and ankle joints, external moments, the patellofemoral/patellar tendon load and integrated EMG of gastrocnemius, tibialis anterior, rectus femoris and biceps femoris were evaluated. As the decline angle increased up to 20 degrees, the range of motion possible at the ankle and knee increased. The joint moments showed a decrease at the ankle up to 15 degrees and an increase at the knee up to 25 degrees, indicating a progressive reduction in loading around the ankle with a corresponding increase of the load in the patellar tendon and patellofemoral joint. These trends were supported by a decrease in tibialis anterior activity and an increase in the rectus femoris activity up to 15 degrees declination. However, gastrocnemius and biceps femoris activity increased as the decline angle increased above 15 degrees. The action of gastrocnemius and biceps femoris stabilises the knee against an anterior displacement of the femur on the tibia. These findings would suggest that there is little benefit in using a decline angle greater than 15-20 degrees unless the purpose is to offer an additional stability challenge to the knee joint.

  6. The effect of different decline angles on the biomechanics of double limb squats and the implications to clinical and training practice

    PubMed Central

    Richards, Jim; Selfe, James; Sinclair, Jonathan; May, Karen; Thomas, Gavin

    2016-01-01

    Abstract Bilateral decline squatting has been well documented as a rehabilitation exercise, however, little information exists on the optimum angle of decline. The aim of this study was to determine the ankle and knee angle, moments, the patellofemoral joint load, patellar tendon load and associated muscle activity while performing a double limb squat at different decline angles and the implications to rehabilitation. Eighteen healthy subjects performed double limb squats at 6 angles of declination: 0, 5, 10, 15, 20 and 25 degrees. The range of motion of the knee and ankle joints, external moments, the patellofemoral/patellar tendon load and integrated EMG of gastrocnemius, tibialis anterior, rectus femoris and biceps femoris were evaluated. As the decline angle increased up to 20 degrees, the range of motion possible at the ankle and knee increased. The joint moments showed a decrease at the ankle up to 15 degrees and an increase at the knee up to 25 degrees, indicating a progressive reduction in loading around the ankle with a corresponding increase of the load in the patellar tendon and patellofemoral joint. These trends were supported by a decrease in tibialis anterior activity and an increase in the rectus femoris activity up to 15 degrees declination. However, gastrocnemius and biceps femoris activity increased as the decline angle increased above 15 degrees. The action of gastrocnemius and biceps femoris stabilises the knee against an anterior displacement of the femur on the tibia. These findings would suggest that there is little benefit in using a decline angle greater than 15-20 degrees unless the purpose is to offer an additional stability challenge to the knee joint. PMID:28149400

  7. Patellar tendinopathy in young elite soccer- clinical and sonographical analysis of a German elite soccer academy.

    PubMed

    Bode, Gerrit; Hammer, Thorsten; Karvouniaris, N; Feucht, M J; Konstantinidis, L; Südkamp, N P; Hirschmüller, A

    2017-08-08

    The prevalence of patellar tendinopathy is elevated in elite soccer compared to less explosive sports. While the burden of training hours and load is comparably high in youth elite players (age < 23 years), little is known about the prevalence of patellar tendinopathy at this age. There is only little data available on the influence of age, the amount of training, the position on the field, as well as muscular strength, range of motion, or sonographical findings in this age group. The purpose of the present study was to examine the above-mentioned parameters in all age groups of a German youth elite soccer academy. One hundred nineteen male youth soccer players (age 15,97 ± 2,24 years, height 174, 60 ± 10,16 cm, BMI 21, 24 ± 2,65) of the U-13 to U-23 teams were part of the study. Data acquisition included sport specific parameters such as footwear, amount of training hours, leg dominance, history of tendon pathologies, and clinical examination for palpatory pain, indurations, muscular circumference, and range of motion. Subjective complaints were measured with the Victorian Institute of Sport Assessment Patellar (VISA-P) Score. Furthermore, sonographical examinations (Aplio SSA-770A/80; Toshiba, Tokyo, Japan) with 12-MHz multifrequency linear transducers (8-14 MHz) of both patellar tendons were performed with special emphasis on hyper- and hypo echogenic areas, diameter and neovascularization. The prevalence of patellar tendinopathies was 13.4%. Seventy-five percent of the players complained of pain of their dominant leg with onset of pain at training in 87.5%. The injured players showed a medium amount of 10.34 ± 3.85 training hours and a medium duration of symptoms of 11.94 ± 18.75 weeks. Two thirds of players with patellar tendinopathy were at the age of 15-17 (Odds ratio 1.89) while no differences between players of the national or regional league were observed. In case of patellar tendinopathy, VISA-P was significantly lower in comparison to healthy players (mean ± SD 76.80 ± 28.56 points vs. 95.85 ± 10.37). The clinical examination revealed local pain at the distal patella, pain at stretching, and thickening of the patellar tendon (p = 0.02). The mean tendon diameter measured 2 cm distally to the patella was 4.10 ± 0.68 mm with a significantly increased diameter of 0.15 mm in case of an underlying tendinopathy (p = 0.00). The incidence of hypo-echogenic areas and neovascularizations was significantly elevated in players with patellar tendon syndrome (PTS) (p = 0.05). The prevalence of patellar tendinopathy in youth elite soccer is relatively high in comparison to available data of adult players. Especially players at the age of 15 to 17 are at considerable risk. Tendon thickening, hypo-echogenic areas, and neovascularization are more common in tendons affected by PTS.

  8. A soft patellar tendon on ultrasound elastography is associated with pain and functional deficit in volleyball players.

    PubMed

    Ooi, Chin Chin; Richards, Paula J; Maffulli, Nicola; Ede, David; Schneider, Michal E; Connell, David; Morrissey, Dylan; Malliaras, Peter

    2016-05-01

    To investigate the diagnostic performance of grey scale Ultrasound (US), power Doppler (PD) and US elastography for diagnosing painful patellar tendinopathy, and to establish their relationship with Victorian Institute of Sport Assessment-Patella (VISA-P) scores in a group of volleyball players with and without symptoms of patellar tendinopathy. Cross-sectional study. Thirty-five volleyball players (70 patellar tendons) were recruited during a national university volleyball competition. Players were imaged with conventional US followed by elastography. The clinical findings of painful patellar tendons were used as the reference standard for diagnosing patellar tendinopathy. In addition, all participants completed the VISA-P questionnaires. Of the 70 patellar tendons, 40 (57.1%) were clinically painful. The diagnostic accuracy of grey scale US, PD and elastography were 60%, 50%, 62.9%, respectively, with sensitivity/specificity of 72.5%/43.3%, 12.5%/100%, and 70%/53.3%, respectively. Combined US elastography and grey scale imaging achieved 82.5% sensitivity, 33.3% specificity and 61.4% accuracy while routine combination technique of PD and grey scale imaging revealed 72.5% sensitivity, 43.3% specificity and 60.0% accuracy. Tendons in players categorized as soft on elastography had statistically significantly greater AP thickness (p<0.001) and lower VISA-P scores (p=0.004) than those categorized as hard. There was no significant association between grey scale US abnormalities (hypoechogenicities and/or fusiform swelling) and VISA-P scores (p=0.098). Soft tendon properties depicted by US elastography may be more related to patellar tendon symptoms compared to grey scale US abnormalities. The supplementation of US elastography to conventional US may enhance the sensitivity for diagnosing patellar tendinopathy in routine clinical practice. Copyright © 2015 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  9. The immediate effect of patellar tendon strap on weight-bearing asymmetry during squatting in patients with unilateral knee osteoarthritis: A pilot study.

    PubMed

    Demirbüken, İlkşan; Özyürek, Seher; Angın, Salih

    2016-12-01

    Knee osteoarthritis has commonly been associated with a symptom of pain resulting in an inter-limb weight-bearing asymmetry during functional tasks. Patellar tendon strap is one of the non-pharmacologic interventions to alleviate knee pain. To investigate the immediate effect of a patellar tendon strap on weight-bearing asymmetry during squatting in people with unilateral knee osteoarthritis. Cross-sectional study. Ten patients with unilateral knee osteoarthritis and 10 healthy subjects were included in the study. Weight-bearing asymmetry of patients was assessed using a weight-bearing squat test during squatting at 30° and 60° both with and without patellar tendon strap. Pain intensity was assessed during squatting in unstrapped and strapped conditions with Visual Analog Scale. The decrease in weight-bearing asymmetry values immediately after wearing patellar tendon strap during 30° (p = 0.006) and 60° (p = 0.011) of squatting tests was significantly higher in knee osteoarthritis patients than in healthy subjects. Reported pain intensity was similar in unstrapped and strapped conditions (p = 0.066). The results of this study showed improved inter-limb weight-bearing symmetry during squatting. Further research with larger sample sizes investigating the effect of patellar tendon strap on weight-bearing asymmetry during functional activities in people with knee osteoarthritis is warranted. Patellar tendon straps (easily fit and cheap unlike knee braces) had more improvements in inter-limb weight-bearing symmetry during squatting in people with knee osteoarthritis compared to healthy subjects. This study is a new insight for future studies to investigate clinical benefits of wearing patellar tendon straps in this population. © The International Society for Prosthetics and Orthotics 2015.

  10. Patellar Sleeve Fracture With Ossification of the Patellar Tendon.

    PubMed

    Damrow, Derek S; Van Valin, Scott E

    2017-03-01

    Patellar sleeve fractures make up greater than 50% of all patellar fractures. They are essentially only seen in the pediatric population because of the thick periosteum and the distal patellar pole apophysis in this group. These fractures can lead to complications if not treated appropriately and in a timely fashion. Complications of missed or untreated patellar sleeve fractures include patella alta, anterior knee pain, and quadriceps atrophy. These can all result in severe limitations in activity. The authors describe a case of a 16-year-old boy who sustained a patellar sleeve fracture 3 years prior to presentation. On presentation, he had patella alta, diminished strength, 5° of extensor lag, and radiographs that revealed bone formation along the patellar tendon. Despite this, he was able to maintain a high level of activity. This case report explores how the patient could have maintained a high level of activity despite having a patellar sleeve fracture. Also, because of the delayed presentation, the patella was ossified and the quadriceps was retracted, which led to a novel approach to reconstructing his distal extensor mechanism. This approach included a V-Y advancement of the quadriceps tendon and patellar tendon reconstruction using the patient's hamstring tendon (semitendinosus). This technique, combined with physical therapy postoperatively, resulted in his return to varsity high school soccer. To the best of the authors' knowledge, this technique has not been reported for this rare condition. [Orthopedics. 2017; 40(2):e357-e359.]. Copyright 2016, SLACK Incorporated.

  11. Tendon fatigue in response to mechanical loading

    PubMed Central

    Andarawis-Puri, N.; Flatow, E. L.

    2015-01-01

    Tendinopathies are commonly attributable to accumulation of sub-rupture fatigue damage from repetitive use. Data is limited to late stage disease from patients undergoing surgery, motivating development of animal models, such as ones utilizing treadmill running or repetitive reaching, to investigate the progression of tendinopathies. We developed an in vivo model using the rat patellar tendon that allows control of the loading directly applied to the tendon. This manuscript discusses the response of tendons to fatigue loading and applications of our model. Briefly, the fatigue life of the tendon was used to define low, moderate and high levels of fatigue loading. Morphological assessment showed a progression from mild kinks to fiber disruption, for low to high level fatigue loading. Collagen expression, 1 and 3 days post loading, showed more modest changes for low and moderate than high level fatigue loading. Protein and mRNA expression of Ineterleukin-1β and MMP-13 were upregulated for moderate but not low level fatigue loading. Moderate level (7200 cycles) and 100 cycles of fatigue loading resulted in a catabolic and anabolic molecular profile respectively, at both 1 and 7 days post loading. Results suggest unique mechanisms for different levels of fatigue loading that are distinct from laceration. PMID:21625047

  12. Extracorporeal shock wave therapy in treatment of delayed bone-tendon healing.

    PubMed

    Wang, Lin; Qin, Ling; Lu, Hong-bin; Cheung, Wing-hoi; Yang, Hu; Wong, Wan-nar; Chan, Kai-ming; Leung, Kwok-sui

    2008-02-01

    Extracorporeal shock wave therapy is indicated for treatment of chronic injuries of soft tissues and delayed fracture healing and nonunion. No investigation has been conducted to study the effect of shock wave on delayed healing at the bone-tendon junction. Shock wave promotes osteogenesis, regeneration of fibrocartilage zone, and remodeling of healing tissue in delayed healing of bone-tendon junction surgical repair. Controlled laboratory study. Twenty-eight mature rabbits were used for establishing a delayed healing model at the patella-patellar tendon complex after partial patellectomy and then divided into control and shock wave groups. In the shock wave group, a single shock wave treatment was given at week 6 postoperatively to the patella-patellar tendon healing complex. Seven samples were harvested at week 8 and 7 samples at week 12 for radiologic, densitometric, histologic, and mechanical evaluations. Radiographic measurements showed 293.4% and 185.8% more new bone formation at the patella-patellar tendon healing junction in the shock wave group at weeks 8 and 12, respectively. Significantly better bone mineral status was found in the week 12 shock wave group. Histologically, the shock wave group showed more advanced remodeling in terms of better alignment of collagen fibers and thicker and more mature regenerated fibrocartilage zone at both weeks 8 and 12. Mechanical testing showed 167.7% and 145.1% higher tensile load and strength in the shock wave group at week 8 and week 12, respectively, compared with controls. Extracorporeal shock wave promotes osteogenesis, regeneration of fibrocartilage zone, and remodeling in the delayed bone-to-tendon healing junction in rabbits. These results provide a foundation for future clinical studies toward establishment of clinical indication for treatment of delayed bone-to-tendon junction healing.

  13. Avulsion fracture of an ossified pes anserinus tendon post-lateral patellar dislocation.

    PubMed

    Albtoush, Omar M; Taib, Abtehag A; Horger, Marius; Springer, Fabian

    2018-05-01

    The pes anserinus is a common tendon comprising the tendinous insertions of the sartorius, gracilis, and semitendinosus muscles. It inserts at the anteromedial aspect of the tibia and plays a significant role in stabilization of the medial side of the knee joint. The current article presents a case with recurrent lateral patellar dislocations causing chronic stress along the medial knee stabilizers and consecutive enthesophyte formation at the insertion of the pes anserinus tendon that showed a transverse fracture upon a subsequent incident of traumatic lateral patellar dislocation. Avulsion injuries of the pes anserinus tendon are rarely encountered, and to our knowledge, association with recurrent lateral patellar dislocations has not been described before.

  14. PT-12, a putative ras-activated proliferation-dependent gene, is expressed in patellar tendon and not in anterior cruciate ligament.

    PubMed

    Goomer, R S; Maris, T; Ostrander, R; Amiel, D

    1999-09-01

    We describe a gene (PT-12) that is expressed in the patellar tendon and not in the anterior cruciate ligament. We used a recently developed polymerase chain reaction-based subtractive cDNA analysis to discover genes that are overexpressed in the patellar tendon but not expressed in the anterior cruciate ligament; the long-term objective was to find genes that are central to the self-repair of the patellar tendon, in contrast with the inability of the anterior cruciate ligament to launch a repair response following injury. PT-12 is a homologue of human S2 or mouse LLRep3 ribosomal genes, which are known to be overexpressed in highly proliferating cells. This study opens a new vista to the development of techniques and reagents to study the differences between two periarticular tissues (i.e., the patellar tendon and anterior cruciate ligament) that differ primarily in their ability to self-repair.

  15. Surgical repair of chronic patellar tendon rupture in total knee replacement with ipsilateral hamstring tendons.

    PubMed

    Spoliti, Marco; Giai Via, Alessio; Padulo, Johnny; Oliva, Francesco; Del Buono, Angelo; Maffulli, Nicola

    2016-10-01

    Patellar tendon rupture is a serious complication of total knee arthroplasty (TKA). Its reconstruction in patients with chronic ruptures is technically demanding. This article reports the results of surgical reconstruction of neglected patellar tendon rupture in TKA using autologous hamstring tendons. Nine TKA patients (six women and three men) (mean age at index surgery 68 years) with chronic patellar tendon tears underwent reconstruction with ipsilateral hamstrings tendon, leaving the distal insertion in situ. The clinical diagnosis was supported by imaging (anterior-posterior and 30° flexion lateral radiographs). Insall-Salvati index, range of motion, and leg extension test were recorded preoperatively and at last follow-up. The modified Cincinnati rating system and the Kujala score were administered. The patients sustained the patellar tendon tear an average of 8 weeks before the procedure. At final follow-up of 4 years (range 2-8 years), the median of extension lag was 5° (range 0°-15°; DS = 5). The median of post-operative Insall-Salvati index was 1.4 (range 1.3-1.8; SD = 0.15; p = 0.002) compared to the preoperative index of 1.7 (range 1.5-2.2; SD = 0.23). The mean modified Cincinnati and Kujala scores significantly increased compared with the preoperative ones (p < 0.01). At final follow-up, all patients were able to walk without brace or aids, and they were satisfied with the procedure. Based on our retrospective study of nine patients, reconstruction of neglected patellar tendon rupture in TKA with autologous hamstring tendons is feasible and safe, and provides good functional recovery. Case series, Level IV.

  16. Radiographic Features of Acute Patellar Tendon Rupture.

    PubMed

    Fazal, Muhammad Ali; Moonot, Pradeep; Haddad, Fares

    2015-11-01

    The purpose of our study was to assess soft tissue features of acute patellar tendon rupture on lateral knee radiograph that would facilitate early diagnosis. The participants were divided into two groups of 35 patients each. There were 28 men and seven women with a mean age of 46 years in the control group and 26 men and nine women with a mean age of 47 years in the rupture group. The lateral knee radiograph of each patient was evaluated for Insall-Salvati ratio for patella alta, increased density of the infrapatellar fat pad, appearance of the soft tissue margin of the patellar tendon and bony avulsions. In the rupture group there were three consistent soft tissue radiographic features in addition to patellar alta. These were increased density of infrapatellar fat pad; loss of sharp, well-defined linear margins of the patellar tendon and angulated wavy margin of the patellar tendon while in the control group these features were not observed. The soft tissue radiographic features described in the rupture group are consistent and reliable. When coupled with careful clinical assessment, these will aid in early diagnosis and further imaging will be seldom required. © 2015 Chinese Orthopaedic Association and Wiley Publishing Asia Pty Ltd.

  17. Characterising the proximal patellar tendon attachment and its relationship to skeletal maturity in adolescent ballet dancers

    PubMed Central

    Rudavsky, Aliza; Cook, Jillianne; Magnusson, Stig Peter; Kjaer, Michael; Docking, Sean

    2017-01-01

    Summary Background It is unknown how and when the proximal attachment of the patellar tendon matures; puberty may be key in ensuring normal tendon formation. The aim of this study was to investigate the features of the proximal patellar tendon attachment at different stages of skeletal maturity, to help gain an understanding of how and when the tendon attachment matures. Methods Sixty adolescent elite ballet students (ages 11–18) and eight mature adults participated. Peak height velocity (PHV) estimated skeletal maturity. Ultrasound tissue characterisation (UTC) scan was taken of the left knee and analysed for stability of echopattern. An image-based grading scale for greyscale ultrasound was developed to describe the tendon appearance. Anterior-posterior thickness was measured at the inferior pole of the patella, 1 and 2 centimetres distally. Outcomes were compared with skeletal maturity. Results Mid-portion patellar tendon thickness increased with skeletal maturity (p=0.001 at 1 cm and p=0.007 at 2 cm). There was more variance in structural appearance (greyscale classification and UTC echopattern) in pre and peri-PHV participants. Tendon attachment one-year post PHV appeared similar to mature tendons. Conclusions Early adolescence was associated with highly variable tendon appearance, whereas the tendon appeared mature after PHV. Adolescence may be a critical time for the formation of normal tendon attachment. Level of evidence IIb individual cohort study. PMID:29264342

  18. Bilateral Patellar Tendon Rupture.

    PubMed

    Kamienski, Mary

    The knee is the most complex and largest joint in the body. Injuries to any part of this joint affect the entire body. There are multiple injuries that can occur to the knee, with the most common being ligament and meniscus tears. A not-so-common injury to the knee is a patellar tendon rupture. A bilateral patellar tendon rupture is extremely rare. A case study of a 43-year-old man who sustained a bilateral patellar tendon rupture while playing softball is used to present this devastating injury. This discussion includes the incidence and diagnosis of the tear, surgical repair, as well as a description of the comprehensive rehabilitation process necessary to allow the patient to return to normal physical activity. Risks and complications of this surgery and the expected outcomes are also presented.

  19. The prevalence of Achilles and patellar tendon injuries in Australian football players beyond a time-loss definition.

    PubMed

    Docking, S I; Rio, E; Cook, J; Orchard, J W; Fortington, L V

    2018-03-23

    Little is known about the prevalence and associated of morbidity of tendon problems. With only severe cases of tendon problems missing games, players that have their training and performance impacted are not captured by traditional injury surveillance. The aim of this study was to report the prevalence of Achilles and patellar tendon problems in elite male Australian football players using the Oslo Sports Trauma Research Centre (OSTRC) overuse questionnaire, compared to a time-loss definition. Male athletes from 12 professional Australian football teams were invited to complete a monthly questionnaire over a 9-month period in the 2016 pre- and competitive season. The OSTRC overuse injury questionnaire was used to measure the prevalence and severity of Achilles and patellar tendon symptoms and was compared to traditional match-loss statistics. A total of 441 participants were included. Of all participants, 21.5% (95% CI: 17.9-25.6) and 25.2% (95% CI 21.3-29.4) reported Achilles or patellar tendon problems during the season, respectively. Based on the traditional match-loss definition, a combined 4.1% of participants missed games due to either Achilles or patellar tendon injury. A greater average monthly prevalence was observed during the pre-season compared to the competitive season. Achilles and patellar tendon problems are prevalent in elite male Australian football players. These injuries are not adequately captured using a traditional match-loss definition. Prevention of these injuries may be best targeted during the off- and pre-season due to higher prevalence of symptoms during the pre-season compared to during the competitive season. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Do peak torque angles of muscles change following anterior cruciate ligament reconstruction using hamstring or patellar tendon graft?

    PubMed

    Yosmaoğlu, Hayri Baran; Baltacı, Gül; Sönmezer, Emel; Özer, Hamza; Doğan, Deha

    2017-12-01

    This study aims to compare the effects of anterior cruciate ligament (ACL) reconstruction using autogenous hamstring or patellar tendon graft on the peak torque angle. The study included 132 patients (103 males, 29 females; mean age 29±9 year) who were performed ACL reconstruction with autogenous hamstring or patellar tendon graft. The peak torque angles in the quadriceps and hamstring muscles were recorded using an isokinetic dynamometer. Angle of peak knee flexion torque occurred significantly earlier within the range of motion on the operated side than nonoperated side at 180°/second in the hamstring tendon group. Angle of peak knee extension torque occurred significantly earlier within the range of motion on the operated side than nonoperated side at 180°/second in the patellar tendon group. There were no statistically significant differences in the flexion and extension peak torque angles between the operated and nonoperated knees at 60°/second in both groups. The angle of peak torque at relatively high angular velocities is affected after ACL reconstruction in patients with hamstring or patellar tendon grafts. The graft donor site directly influences this parameter. This finding may be important for clinicians in terms of preventing re-injury.

  1. The relationships among spatiotemporal collagen gene expression, histology, and biomechanics following full-length injury in the murine patellar tendon.

    PubMed

    Dyment, Nathaniel A; Kazemi, Namdar; Aschbacher-Smith, Lindsey E; Barthelery, Nicolas J; Kenter, Keith; Gooch, Cynthia; Shearn, Jason T; Wylie, Christopher; Butler, David L

    2012-01-01

    Tendon injuries are major orthopedic problems that worsen as the population ages. Type-I (Col1) and type-II (Col2) collagens play important roles in tendon midsubstance and tendon-to-bone insertion healing, respectively. Using double transgenic mice, this study aims to spatiotemporally monitor Col1 and Col2 gene expression, histology, and biomechanics up to 8 weeks following a full-length patellar tendon injury. Gene expression and histology were analyzed weekly for up to 5 weeks while mechanical properties were measured at 1, 2, 5, and 8 weeks. At week 1, the healing region displayed loose granulation tissue with little Col1 expression. Col1 expression peaked at 2 weeks, but the ECM was highly disorganized and hypercellular. By 3 weeks, Col1 expression had reduced and by 5 weeks, the ECM was generally aligned along the tendon axis. Col2 expression was not seen in the healing midsubstance or insertion at any time point. The biomechanics of the healing tissue was inadequate at all time points, achieving ultimate loads and stiffnesses of 48% and 63% of normal values by 8 weeks. Future studies will further characterize the cells within the healing midsubstance and insertion using tenogenic markers and compare these results to those of tendon cells during normal development. Copyright © 2011 Orthopaedic Research Society.

  2. Reconstruction of the extensor mechanism with fresh-frozen tendon allograft in total knee arthroplasty.

    PubMed

    Llombart Blanco, Rafael; Valentí, Andrés; Díaz de Rada, Pablo; Mora, Gonzalo; Valentí, Juan R

    2014-11-01

    Patellar tendon rupture after total knee replacement is a rare and highly limiting injury with multifactorial aetiology. Many reconstruction techniques have been described with not very predictable results. The use of allografts has been accepted as a suitable solution. A series of seven patients with patellar tendon rupture treated with fresh-frozen tendon allograft reconstruction after knee arthroplasty is presented. Median follow-up is 25 months (20-31). Functional assessment improved, and the knee society score and knee functional score improved from 26 and 16 to 82 and 55, respectively. Median extension lag was 5° (0°-20°), with a median range of motion of 95° (70-100). Radiological study showed a rise of the patella of 22.26 mm. The use of fresh-frozen allografts as a solution to patellar tendon ruptures after knee arthroplasty seems to provide acceptable results. Increased patellar height does not seem to affect functionality. Case series, Level IV.

  3. Knee isokinetic performance following anterior cruciate ligament reconstruction: patellar tendon versus hamstrings graft.

    PubMed

    Machado, Felipe; Debieux, Pedro; Kaleka, Camila Cohen; Astur, Diego; Peccin, Maria Stella; Cohen, Moisés

    2018-02-01

    To compare knee isokinetic performance six months after reconstruction of the anterior cruciate ligament using grafts from either the patellar tendon or the hamstrings among patients who underwent the same rehabilitation protocol. Thirty-four patients were evaluated (17 with grafts from the patellar tendon and 17 with grafts from the hamstrings). Operated and non-operated knees were compared with regards to the variables of peak torque, work and the hamstring/quadriceps relationship at velocities of 60º/s and 180º/s and power of 180º/s after six months of surgery. The patients with ACL reconstruction using the patellar tendon (BPTB) showed quadriceps deficits for all variables, but the flexor musculature was balanced. In the hamstring group, both the extensors and the flexors showed deficits for the variables analyzed, except for hamstring power at 180º/s. Patients in the patellar tendon group had a greater quadriceps deficit compared with those in the hamstrings group. Patients in the hamstrings group had a greater muscular deficit in the flexor mechanism compared with the contralateral knee. An unbalanced H/Q ratio was observed regardless of graft type, but this was more evident in the BPTB group.

  4. Structure, ontogeny and evolution of the patellar tendon in emus (Dromaius novaehollandiae) and other palaeognath birds

    PubMed Central

    Pitsillides, Andrew A.; Hutchinson, John R.

    2014-01-01

    The patella (kneecap) exhibits multiple evolutionary origins in birds, mammals, and lizards, and is thought to increase the mechanical advantage of the knee extensor muscles. Despite appreciable interest in the specialized anatomy and locomotion of palaeognathous birds (ratites and relatives), the structure, ontogeny and evolution of the patella in these species remains poorly characterized. Within Palaeognathae, the patella has been reported to be either present, absent, or fused with other bones, but it is unclear how much of this variation is real, erroneous or ontogenetic. Clarification of the patella’s form in palaeognaths would provide insight into the early evolution of the patella in birds, in addition to the specialized locomotion of these species. Findings would also provide new character data of use in resolving the controversial evolutionary relationships of palaeognaths. In this study, we examined the gross and histological anatomy of the emu patellar tendon across several age groups from five weeks to 18 months. We combined these results with our observations and those of others regarding the patella in palaeognaths and their outgroups (both extant and extinct), to reconstruct the evolution of the patella in birds. We found no evidence of an ossified patella in emus, but noted its tendon to have a highly unusual morphology comprising large volumes of adipose tissue contained within a collagenous meshwork. The emu patellar tendon also included increasing amounts of a cartilage-like tissue throughout ontogeny. We speculate that the unusual morphology of the patellar tendon in emus results from assimilation of a peri-articular fat pad, and metaplastic formation of cartilage, both potentially as adaptations to increasing tendon load. We corroborate previous observations of a ‘double patella’ in ostriches, but in contrast to some assertions, we find independent (i.e., unfused) ossified patellae in kiwis and tinamous. Our reconstructions suggest a single evolutionary origin of the patella in birds and that the ancestral patella is likely to have been a composite structure comprising a small ossified portion, lost by some species (e.g., emus, moa) but expanded in others (e.g., ostriches). PMID:25551026

  5. Teaching enthesis ultrasound: experience of an ultrasound training workshop.

    PubMed

    Miguel, Cláudia; De Miguel, Eugenio; Batlle-Gualda, Enrique; Rejón, Eduardo; Lojo, Leticia

    2012-12-01

    To evaluate a standardised enthesis ultrasound training method, a workshop was conducted to train rheumatologists on enthesis ultrasound. After a theoretical session about ultrasound elementary enthesis lesions (changes in tendon architecture/thickness, bone proliferation/erosion, bursitis or Doppler signal), a reading exercise of 28 entheses' ultrasonographic images (plantar fasciae, Achilles, origin and insertion of patellar tendon) was completed. Participants scored through an electronic multiple-choice device with six possible lesions in each enthesis. To assess the adequacy and efficacy of the workshop, we explored the following: (1) subjective outcomes: a 12-item structured satisfaction questionnaire (graded 1-5 using Likert scale) and (2) objective outcomes of reliability: sensitivity (Se), specificity (Sp) and percentage of correctly classified cases (CC). Forty-nine participants attended the workshop. The satisfaction questionnaire demonstrated a 4.7 mean global value. The inter-reader Kappa reliability coefficient was moderate for the plantar fascia (0.47), Achilles tendon (0.47), and distal patellar tendons (0.50) and good for the proximal patellar tendon (0.63). The whole group means comparing to teachers' consensus were as follows: (a) plantar fascia: Se, 73.2%; Sp, 87.7%; CC, 83.3%; (b) Achilles: Se, 66.9%; Sp, 85.0%; CC, 79.5%; (c) distal patellar tendon: Se, 74.6%; Sp, 85.3%; CC, 82.1%; and (d) proximal patellar tendon: Se, 82.2%; Sp, 90.6%; CC, 88%. The proposed learning method seemed to be simple, easily performed, effective and well accepted by the target audience.

  6. Abnormal Patella Height Based on Insall-Salvati Ratio and its Correlation with Patellar Cartilage Lesions: An Extremity-Dedicated Low-Field Magnetic Resonance Imaging Analysis of 1703 Chinese Cases.

    PubMed

    Lu, W; Yang, J; Chen, S; Zhu, Y; Zhu, C

    2016-09-01

    Diagnostic performance of patellar position for patellar cartilage lesions remains unclear. The aim of this study was to assess the abnormal patella height and its correlation with chondral lesions of the patellofemoral joint in China. A total of 1703 consecutive patients who performed knee joint examination using an extremity-dedicated low-field magnetic resonance imaging were enrolled in this study. Patellar cartilage lesions were diagnosed based on the result of magnetic resonance imaging and clinical data. Patella height was defined as the ratio of patellar tendon length to patellar length according to Insall-Salvati index. Patella alta and infera were defined as tendon length/patellar length >1.2 and <0.8, respectively. The total prevalence of patellar cartilage lesions was 38.0%. The prevalence in females was significantly higher than that in males (46.4% vs 28.8%, p < 0.001). Age notably increased the incidence of patellar cartilage lesions (p < 0.001). Logistic regression analysis showed that tendon length/patellar length ratio was significantly correlated with patellar cartilage lesions (odds ratio = 6.380, p < 0.001). Furthermore, patients with cartilage lesions showed significantly higher rates of patella alta and infera (p < 0.001). In addition, receiver operating characteristic curve analysis demonstrated that abnormal patella height had statistical significance in diagnosing cartilage lesions (p < 0.001). However, the area under the curve (0.596; 95% confidence interval: 0.568-0.624) and sensitivity (47.0%) were relatively low, while the specificity was 72.2%. Patients with patellar cartilage lesions have an increased tendon length/patellar length ratio. The abnormal patella height is significantly correlated with chondral lesions and can be used as a potential diagnostic marker. © The Finnish Surgical Society 2015.

  7. Changes in Morphological and Elastic Properties of Patellar Tendon in Athletes with Unilateral Patellar Tendinopathy and Their Relationships with Pain and Functional Disability

    PubMed Central

    Zhang, Zhi Jie; Ng, Gabriel Yin-fat; Lee, Wai Chun; Fu, Siu Ngor

    2014-01-01

    Background Patellar tendinopathy (PT) is one of the most common knee disorders among athletes. Changes in morphology and elasticity of the painful tendon and how these relate to the self-perceived pain and dysfunction remain unclear. Objectives To compare the morphology and elastic properties of patellar tendons between athlete with and without unilateral PT and to examine its association with self-perceived pain and dysfunction. Methods In this cross-sectional study, 33 male athletes (20 healthy and 13 with unilateral PT) were enrolled. The morphology and elastic properties of the patellar tendon were assessed by the grey and elastography mode of supersonic shear imaging (SSI) technique while the intensity of pressure pain, self-perceived pain and dysfunction were quantified with a 10-lb force to the most painful site and the Victorian Institute of Sport Assessment-patella (VISA-P) questionnaire, respectively. Results In athletes with unilateral PT, the painful tendons had higher shear elastic modulus (SEM) and larger tendon than the non-painful side (p<0.05) or the dominant side of the healthy athletes (p<0.05). Significant correlations were found between tendon SEM ratio (SEM of painful over non-painful tendon) and the intensity of pressure pain (rho  = 0.62; p = 0.024), VISA-P scores (rho  = −0.61; p = 0.026), and the sub-scores of the VISA-P scores on going down stairs, lunge, single leg hopping and squatting (rho ranged from −0.63 to −0.67; p<0.05). Conclusions Athletes with unilateral PT had stiffer and larger tendon on the painful side than the non-painful side and the dominant side of healthy athletes. No significant differences on the patellar tendon morphology and elastic properties were detected between the dominant and non-dominant knees of the healthy control. The ratio of the SEM of painful to non-painful sides was associated with pain and dysfunction among athletes with unilateral PT. PMID:25303466

  8. Dual growth factor-immobilized asymmetrically porous membrane for bone-to-tendon interface regeneration on rat patellar tendon avulsion model.

    PubMed

    Kim, Joong-Hyun; Oh, Se Heang; Min, Hyun Ki; Lee, Jin Ho

    2018-01-01

    Insufficient repair of the bone-to-tendon interface (BTI) with structural/compositional gradients has been a significant challenge in orthopedics. In this study, dual growth factor (platelet-derived growth factor-BB [PDGF-BB] and bone morphogenetic protein-2 [BMP-2])-immobilized polycaprolactone (PCL)/Pluronic F127 asymmetrically porous membrane was fabricated to estimate its feasibility as a potential strategy for effective regeneration of BTI injury. The growth factors immobilized (via heparin-intermediated interactions) on the membrane were continuously released for up to ∼80% of the initial loading amount after 5 weeks without a significant initial burst. From the in vivo animal study using a rat patellar tendon avulsion model, it was observed that the PDGF-BB/BMP-2-immobilized membrane accelerates the regeneration of the BTI injury, probably because of the continuous release of both growth factors (biological stimuli) and their complementary effect to create a multiphasic structure (bone, fibrocartilage, and tendon) like a native structure, as well as the role of the asymmetrically porous membrane as a physical barrier (nanopore side; prevention of fibrous tissue invasion into the defect site) and scaffold (micropore side; guidance for tissue regeneration). © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 115-125, 2018. © 2017 Wiley Periodicals, Inc.

  9. Suture anchor repair of patellar tendon rupture after total knee arthroplasty.

    PubMed

    Kamath, Atul F; Shah, Roshan P; Summers, Nathan; Israelite, Craig L

    2013-12-01

    Extensor mechanism disruption after total knee arthroplasty (TKA) is a complex problem that often requires surgical repair for functional deficits. We present a brief technical note on suture anchor fixation of a patellar tendon rupture after TKA. A surgical technique and literature review follows. Although suture anchor fixation is well described for tendinous repairs in other areas of orthopedic surgery, no study has discussed the use of suture anchors in patellar tendon repair after TKA. The technique must be evaluated in more patients with longer follow-up before adoption. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  10. Faster Movement Speed Results in Greater Tendon Strain during the Loaded Squat Exercise

    PubMed Central

    Earp, Jacob E.; Newton, Robert U.; Cormie, Prue; Blazevich, Anthony J.

    2016-01-01

    Introduction: Tendon dynamics influence movement performance and provide the stimulus for long-term tendon adaptation. As tendon strain increases with load magnitude and decreases with loading rate, changes in movement speed during exercise should influence tendon strain. Methods: Ten resistance-trained men [squat one repetition maximum (1RM) to body mass ratio: 1.65 ± 0.12] performed parallel-depth back squat lifts with 60% of 1RM load at three different speeds: slow fixed-tempo (TS: 2-s eccentric, 1-s pause, 2-s concentric), volitional-speed without a pause (VS) and maximum-speed jump (JS). In each condition joint kinetics, quadriceps tendon length (LT), patellar tendon force (FT), and rate of force development (RFDT) were estimated using integrated ultrasonography, motion-capture, and force platform recordings. Results: Peak LT, FT, and RFDT were greater in JS than TS (p < 0.05), however no differences were observed between VS and TS. Thus, moving at faster speeds resulted in both greater tendon stress and strain despite an increased RFDT, as would be predicted of an elastic, but not a viscous, structure. Temporal comparisons showed that LT was greater in TS than JS during the early eccentric phase (10–14% movement duration) where peak RFDT occurred, demonstrating that the tendon's viscous properties predominated during initial eccentric loading. However, during the concentric phase (61–70 and 76–83% movement duration) differing FT and similar RFDT between conditions allowed for the tendon's elastic properties to predominate such that peak tendon strain was greater in JS than TS. Conclusions: Based on our current understanding, there may be an additional mechanical stimulus for tendon adaptation when performing large range-of-motion isoinertial exercises at faster movement speeds. PMID:27630574

  11. Adaptation of bone and tendon to prolonged hindlimb suspension in rats

    NASA Technical Reports Server (NTRS)

    Vailas, Arthur C.; Deluna, Diane M.; Lewis, Lisa L.; Curwin, Sandra L.; Roy, Roland R.

    1988-01-01

    The effect of a sustained deprivation of ground reaction forces on mineralized and soft connective tissues was investigated in rats subjected to 28-d-long hind-limb suspension. The results of morphological and biochemical studies carried out on femurs and patellar tendons obtained from suspended and nonsuspended 110-d-old rats showed that prolonged suspension led to an increase of the minimum diameter of the femur middiaphysis (by 12 percent), without any significant alterations in cortical area, density, mineral and collagen concentrations, femur wet weight, length, and DNA and uronic acid concentrations. However, in the patellar tendons of suspended rats, the collagen and proteoglycan concentrations were 28 percent lower than in tendons obtained from nonsuspended animals. These results suggest that ground reaction forces are important for the maintenance of cortical bone and patellar tendon homeostasis during weight-bearing conditions.

  12. The role of bone sialoprotein in the tendon-bone insertion.

    PubMed

    Marinovich, Ryan; Soenjaya, Yohannes; Wallace, Gregory Q; Zuskov, Andre; Dunkman, Andrew; Foster, Brian L; Ao, Min; Bartman, Kevin; Lam, Vida; Rizkalla, Amin; Beier, Frank; Somerman, Martha J; Holdsworth, David W; Soslowsky, Louis J; Lagugné-Labarthet, François; Goldberg, Harvey A

    2016-01-01

    Tendons/ligaments insert into bone via a transitional structure, the enthesis, which is susceptible to injury and difficult to repair. Fibrocartilaginous entheses contain fibrocartilage in their transitional zone, part of which is mineralized. Mineral-associated proteins within this zone have not been adequately characterized. Members of the Small Integrin Binding Ligand N-linked Glycoprotein (SIBLING) family are acidic phosphoproteins expressed in mineralized tissues. Here we show that two SIBLING proteins, bone sialoprotein (BSP) and osteopontin (OPN), are present in the mouse enthesis. Histological analyses indicate that the calcified zone of the quadriceps tendon enthesis is longer in Bsp(-/-) mice, however no difference is apparent in the supraspinatus tendon enthesis. In an analysis of mineral content within the calcified zone, micro-CT and Raman spectroscopy reveal that the mineral content in the calcified fibrocartilage of the quadriceps tendon enthesis are similar between wild type and Bsp(-/-) mice. Mechanical testing of the patellar tendon shows that while the tendons fail under similar loads, the Bsp(-/-) patellar tendon is 7.5% larger in cross sectional area than wild type tendons, resulting in a 16.5% reduction in failure stress. However, Picrosirius Red staining shows no difference in collagen organization. Data collected here indicate that BSP is present in the calcified fibrocartilage of murine entheses and suggest that BSP plays a regulatory role in this structure, influencing the growth of the calcified fibrocartilage in addition to the weakening of the tendon mechanical properties. Based on the phenotype of the Bsp(-/-) mouse enthesis, and the known in vitro functional properties of the protein, BSP may be a useful therapeutic molecule in the reattachment of tendons and ligaments to bone. Copyright © 2016 International Society of Matrix Biology. All rights reserved.

  13. The Role of Bone Sialoprotein in the Tendon-Bone Insertion

    PubMed Central

    Marinovich, Ryan; Soenjaya, Yohannes; Wallace, Gregory Q.; Zuskov, Andre; Dunkman, Andrew; Foster, Brian L.; Ao, Min; Bartman, Kevin; Lam, Vida; Rizkalla, Amin; Beier, Frank; Somerman, Martha J.; Holdsworth, David W.; Soslowsky, Louis J.; Lagugné-Labarthet, François; Goldberg, Harvey A.

    2016-01-01

    Tendons/ligaments insert into bone via a transitional structure, the enthesis, which is susceptible to injury and difficult to repair. Fibrocartilaginous entheses contain fibrocartilage in their transitional zone, part of which is mineralized. Mineral-associated proteins within this zone have not been adequately characterized. Members of the Small Integrin Binding Ligand N-Linked Glycoprotein (SIBLING) family are acidic phosphoproteins expressed in mineralized tissues. Here we show that two SIBLING proteins, bone sialoprotein (BSP) and osteopontin (OPN), are present in the mouse enthesis. Histological analyses indicate that the calcified zone of the quadriceps tendon enthesis is longer in Bsp−/− mice, however no difference is apparent in the supraspinatus tendon enthesis. In an analysis of mineral content within the calcified zone, micro-CT and Raman spectroscopy reveal that the mineral content in the calcified fibrocartilage of the quadriceps tendon enthesis are similar between wild type and Bsp−/− mice. Mechanical testing of the patellar tendon shows that while the tendons fail under similar loads, the Bsp−/− patellar tendon is 7.5% larger in cross sectional area than wild type tendons, resulting in a 16.5% reduction in failure stress. However, picrosirius red staining shows no difference in collagen organization. Data collected here indicate that BSP is present in the calcified fibrocartilage of murine entheses and suggest that BSP plays a regulatory role in this structure, influencing the growth of the calcified fibrocartilage in addition to the weakening of the tendon mechanical properties. Based on the phenotype of the Bsp−/− mouse enthesis, and the known in vitro functional properties of the protein, BSP may be a useful therapeutic molecule in the reattachment of tendons and ligaments to bone. PMID:26826499

  14. Regeneration of Musculoskeletal Tissues by Prolonged Low-Grade Inflammation

    DTIC Science & Technology

    2011-10-01

    grade inflammation around a pure collagen based scaffold on implantation into the rabbit patellar tendon. Additionally, the cross-sectional areas of...the tendons treated with the implant were about 40% greater compared to the sham- operated controls. In the current study, we hypothesized that soft...was implanted into the rat patellar tendon using a minimally invasive technique and the inflammation was blocked using liposomal clodronate. The

  15. COMPARISON OF FUNCTIONAL ACTIVITIES ON STRUCTURAL CHANGES OF THE INFERIOR PATELLAR POLE

    PubMed Central

    Wallmann, Harvey; Stalcup, Patrick; DiTommaso, Katie

    2017-01-01

    Background It is well known that eccentric and concentric exercise produce varied amounts of stress on the connective tissues. Diagnostic ultrasound has been used to measure these structural changes by observing fascicle length, angle, and thickness; however, there is a lack of evidence comparing the structural changes as it relates to eccentric, concentric, and stretching protocols. Purpose The purpose of this study was to compare the acute effects of static stretching, eccentric, concentric, and a combination of eccentric/concentric exercises on structural changes of the muscle tendon unit at the inferior patellar pole utilizing the diagnostic ultrasound. Study Design A repeated measures 2 × 4 within factorial study design with repeated measures on both factors was used to determine the differences in patellar tendon thickness within and between groups. Methods Forty-seven healthy subjects were screened for any lower extremity deficits or orthopaedic pathology. Forty-four (N=44) subjects completed all four protocols; the attrition was due to injuries to the lower extremity, occurring unrelated to the study. A baseline measurement of the anterior inferior patellar tendon was performed with the diagnostic ultrasound prior to each participant completing one of the four interventions per week over a four-week period. Interventions completed by each participant included static stretching, concentric, eccentric, and combined concentric and eccentric exercises. Immediately following each intervention, a post-intervention inferior patellar tendon measurement was recorded using the diagnostic ultrasound. Results Significant differences in anterior to posterior tendon thickness of the inferior patellar tendon were observed between pre (4.983 ± 0.041mm) and post (5.198 ± 0.055mm) measurements (p<0.0005) for the main effect of time. However, no differences in tendon thickness were noted comparing each intervention to one another (p=0.351). Conclusion Differences in tendon thickness were noted acutely for pre- to post measurements across all interventions. Further research is needed to determine if differences in tendon thickness exist with a longer duration of exercise over time and with different types of intervention. PMID:29234561

  16. Varying whole body vibration amplitude differentially affects tendon and ligament structural and material properties

    PubMed Central

    Keller, Benjamin V.; Davis, Matthew L.; Thompson, William R.; Dahners, Laurence E.; Weinhold, Paul S.

    2014-01-01

    Whole Body Vibration (WBV) is becoming increasingly popular for helping to maintain bone mass and strengthening muscle. Vibration regimens optimized for bone maintenance often operate at hypogravity levels (<1 G) and regimens for muscle strengthening often employ hypergravity (>1 G) vibrations. The effect of vibratory loads on tendon and ligament properties is unclear though excessive vibrations may be injurious. Our objective was to evaluate how tendon gene expression and the mechanical/histological properties of tendon and ligament were affected in response to WBV in the following groups: no vibration, low vibration (0.3 G peak-to-peak), and high vibration (2 G peak-to-peak). Rats were vibrated for 20 min a day, 5 days a week, for 5 weeks. Upon sacrifice, the medial collateral ligament (MCL), patellar tendon (PT), and the Achilles Tendon (AT) were isolated with insertion sites intact. All tissues were tensile tested to determine structural and material properties or used for histology. Patellar tendon was also subjected to quantitative RT-PCR to evaluate expression of anabolic and catabolic genes. No differences in biomechanical data between the control and the low vibration groups were found. There was evidence of significant weakness in the MCL with high vibration, but no significant effect on the PT or AT. Histology of the MCL and PT showed a hypercellular tissue response and some fiber disorganization with high vibration. High vibration caused an increase in collagen expression and a trend for an increase in IGF-1 expression suggesting a potential anabolic response to prevent tendon overuse injury. PMID:23623311

  17. The Accuracy of the VISA-P Questionnaire, Single-Leg Decline Squat, and Tendon Pain History to Identify Patellar Tendon Abnormalities in Adult Athletes.

    PubMed

    Mendonça, Luciana de Michelis; Ocarino, Juliana Melo; Bittencourt, Natália Franco Netto; Fernandes, Ludmila Maria Oliveira; Verhagen, Evert; Fonseca, Sérgio Teixeira

    2016-08-01

    Study Design Cross-sectional clinical assessment. Background Patellar tendinopathy is not always accompanied by patellar tendon abnormalities (PTAs). Thus, clinical screening tools to help identify patients with patellar tendon pain who have PTAs could enhance clinical decision making and patient prognosis. Objectives To test the diagnostic accuracy of the Victorian Institute of Sport Assessment-Patella (VISA-P) questionnaire, a single-leg decline squat (SLDS), tendon pain history, age, and years of sports participation to identify athletes with symptomatic patellar tendons who have PTAs confirmed on imaging. Methods Data provided by ultrasound examination, the VISA-P questionnaire, the SLDS, tendon pain history, age, and years of sport participation were collected in 43 athletes. A classification and regression tree (CART) model was developed to verify variables associated with PTA occurrence. Likelihood ratios (LRs) were computed for positive and negative tests. Results The SLDS, VISA-P questionnaire, and tendon pain history were associated with PTA occurrence. Athletes with negative results on all 3 tests (CART model) had a lower likelihood of having PTAs (negative LR = 0.3; 95% confidence interval [CI]: 0.2, 0.5). The isolated use of the SLDS or tendon pain history (positive LR = 4.2; 95% CI: 2.3, 7.14 and 4.5; 95% CI: 1.8, 11.1, respectively) had similar influence on probability of PTA presence compared to the CART model (positive LR = 4.1; 95% CI: 2.5, 6.3). Conclusion Although the objective was to investigate a clinical test to identify PTAs, the combined use of the tests had greater accuracy to identify individuals without PTAs. Level of Evidence Diagnosis, level 3b. J Orthop Sports Phys Ther 2016;46(8):673-680. Epub 3 Jul 2016. doi:10.2519/jospt.2016.6192.

  18. Fresh-frozen Complete Extensor Mechanism Allograft versus Autograft Reconstruction in Rabbits

    PubMed Central

    Chen, Guanyin; Zhang, Hongtao; Ma, Qiong; Zhao, Jian; Zhang, Yinglong; Fan, Qingyu; Ma, Baoan

    2016-01-01

    Different clinical results have been reported in the repair of extensor mechanism disruption using fresh-frozen complete extensor mechanism (CEM) allograft, creating a need for a better understanding of fresh-frozen CME allograft reconstruction. Here, we perform histological and biomechanical analyses of fresh-frozen CEM allograft or autograft reconstruction in an in vivo rabbit model. Our histological results show complete incorporation of the quadriceps tendon into the host tissues, patellar survival and total integration of the allograft tibia, with relatively fewer osteocytes, into the host tibia. Vascularity and cellularity are reduced and delayed in the allograft but exhibit similar distributions to those in the autograft. The infrapatellar fat pad provides the main blood supply, and the lowest cellularity is observed in the patellar tendon close to the tibia in both the allograft and autograft. The biomechanical properties of the junction of quadriceps tendon and host tissues and those of the allograft patellar tendon are completely and considerably restored, respectively. Therefore, fresh-frozen CEM allograft reconstruction is viable, but the distal patellar tendon and the tibial block may be the weak links of the reconstruction. These findings provide new insight into the use of allograft in repairing disruption of the extensor mechanism. PMID:26911538

  19. Fresh-frozen Complete Extensor Mechanism Allograft versus Autograft Reconstruction in Rabbits.

    PubMed

    Chen, Guanyin; Zhang, Hongtao; Ma, Qiong; Zhao, Jian; Zhang, Yinglong; Fan, Qingyu; Ma, Baoan

    2016-02-25

    Different clinical results have been reported in the repair of extensor mechanism disruption using fresh-frozen complete extensor mechanism (CEM) allograft, creating a need for a better understanding of fresh-frozen CME allograft reconstruction. Here, we perform histological and biomechanical analyses of fresh-frozen CEM allograft or autograft reconstruction in an in vivo rabbit model. Our histological results show complete incorporation of the quadriceps tendon into the host tissues, patellar survival and total integration of the allograft tibia, with relatively fewer osteocytes, into the host tibia. Vascularity and cellularity are reduced and delayed in the allograft but exhibit similar distributions to those in the autograft. The infrapatellar fat pad provides the main blood supply, and the lowest cellularity is observed in the patellar tendon close to the tibia in both the allograft and autograft. The biomechanical properties of the junction of quadriceps tendon and host tissues and those of the allograft patellar tendon are completely and considerably restored, respectively. Therefore, fresh-frozen CEM allograft reconstruction is viable, but the distal patellar tendon and the tibial block may be the weak links of the reconstruction. These findings provide new insight into the use of allograft in repairing disruption of the extensor mechanism.

  20. Rotator Cuff Repair with a Tendon-Fibrocartilage-Bone Composite Bridging Patch

    PubMed Central

    Ji, Xiaoxi; Chen, Qingshan; Thoreson, Andrew R.; Qu, Jin; An, Kai-Nan; Amadio, Peter C.; Steinmann, Scott P.; Zhao, Chunfeng

    2015-01-01

    Background To compare the mechanical performance of a rotator cuff repaired with a novel tendon-fibrocartilage-bone composite bridging patch vs the traditional Mason-Allen repair in an in vitro canine model. Methods Twenty shoulders and 10 bridging patches from patellar tendon were harvested. The patches were trimmed and sliced into 2 layers. An infraspinatus tendon tear was created in each shoulder. Modified Mason-Allen sutures were used to repair the infraspinatus tendon to the greater tuberosity, with or without the bridging patch (bridging patch group and controls, respectively). Shoulders were loaded to failure under displacement control at a rate of 0.5mm/sec. Findings The ultimate tensile load was significantly higher in the bridging patch group than control (mean [SD], 365.46 [36.45] vs 272.79 [48.88] N; P<.001). Stiffness at the greater tuberosity repair site and the patch-infraspinatus tendon repair site was significantly higher than the control repair site (93.96 [27.72] vs 42.62 [17.48] N/mm P<.001; 65.94 [24.51] vs 42.62 [17.48] N/mm P=.02, respectively). Interpretation The tendon-fibrocartilage-bone composite bridging patch achieved higher ultimate tensile load and stiffness at the patch–greater tuberosity repair site compared with traditional repair in a canine model. This composite tissue transforms the traditional tendon-to-bone healing interface (with dissimilar tissues) into a pair of bone-to-bone and tendon-to-tendon interfaces, which may improve healing quality and reduce retear rate. PMID:26190097

  1. Rotator cuff repair with a tendon-fibrocartilage-bone composite bridging patch.

    PubMed

    Ji, Xiaoxi; Chen, Qingshan; Thoreson, Andrew R; Qu, Jin; An, Kai-Nan; Amadio, Peter C; Steinmann, Scott P; Zhao, Chunfeng

    2015-11-01

    To compare the mechanical performance of a rotator cuff repaired with a novel tendon-fibrocartilage-bone composite bridging patch vs the traditional Mason-Allen repair in an in vitro canine model. Twenty shoulders and 10 bridging patches from patellar tendon were harvested. The patches were trimmed and sliced into 2 layers. An infraspinatus tendon tear was created in each shoulder. Modified Mason-Allen sutures were used to repair the infraspinatus tendon to the greater tuberosity, with or without the bridging patch (bridging patch group and controls, respectively). Shoulders were loaded to failure under displacement control at a rate of 0.5mm/s. The ultimate tensile load was significantly higher in the bridging patch group than control (mean [SD], 365.46 [36.45] vs 272.79 [48.88] N; P<.001). Stiffness at the greater tuberosity repair site and the patch-infraspinatus tendon repair site was significantly higher than the control repair site (93.96 [27.72] vs 42.62 [17.48] N/mm P<.001; 65.94 [24.51] vs 42.62 [17.48] N/mm P=.02, respectively). The tendon-fibrocartilage-bone composite bridging patch achieved higher ultimate tensile load and stiffness at the patch-greater tuberosity repair site compared with traditional repair in a canine model. This composite tissue transforms the traditional tendon-to-bone healing interface (with dissimilar tissues) into a pair of bone-to-bone and tendon-to-tendon interfaces, which may improve healing quality and reduce retear rate. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Free Bone Plug Quadriceps Tendon Harvest and Suspensory Button Attachment for Anterior Cruciate Ligament Reconstruction.

    PubMed

    Todor, Adrian; Caterev, Sergiu; Nistor, Dan Viorel; Khallouki, Youssef

    2016-06-01

    The most commonly used autografts for anterior cruciate ligament reconstruction are the bone-patellar tendon-bone and hamstring tendons. Each has its advantages and limitations. The bone-patellar tendon-bone autograft can lead to more donor-site morbidity, and the hamstring autograft can be unpredictable in size. The quadriceps tendon, with or without a bone block, has been described as an alternative graft source and has been used especially in revision cases, but in recent years, it has attracted attention even for primary cases. We report a technique for harvesting a free bone quadriceps tendon graft and attaching an extracortical button for femoral fixation for anterior cruciate ligament reconstruction.

  3. Immediate effects of whole body vibration on patellar tendon properties and knee extension torque.

    PubMed

    Rieder, F; Wiesinger, H-P; Kösters, A; Müller, E; Seynnes, O R

    2016-03-01

    Reports about the immediate effects of whole body vibration (WBV) exposure upon torque production capacity are inconsistent. However, the changes in the torque-angle relationship observed by some authors after WBV may hinder the measurement of torque changes at a given angle. Acute changes in tendon mechanical properties do occur after certain types of exercise but this hypothesis has never been tested after a bout of WBV. The purpose of the present study was to investigate whether tendon compliance is altered immediately after WBV, effectively shifting the optimal angle of peak torque towards longer muscle length. Twenty-eight subjects were randomly assigned to either a WBV (n = 14) or a squatting control group (n = 14). Patellar tendon CSA, stiffness and Young's modulus and knee extension torque-angle relationship were measured using ultrasonography and dynamometry 1 day before and directly after the intervention. Tendon CSA was additionally measured 24 h after the intervention to check for possible delayed onset of swelling. The vibration intervention had no effects on patellar tendon CSA, stiffness and Young's modulus or the torque-angle relationship. Peak torque was produced at ~70° knee angle in both groups at pre- and post-test. Additionally, the knee extension torque globally remained unaffected with the exception of a small (-6%) reduction in isometric torque at a joint angle of 60°. The present results indicate that a single bout of vibration exposure does not substantially alter patellar tendon properties or the torque-angle relationship of knee extensors.

  4. Characterization of calcium and zinc spatial distributions at the fibrocartilage zone of bone-tendon junction by synchrotron radiation-based micro X-ray fluorescence analysis combined with backscattered electron imaging

    NASA Astrophysics Data System (ADS)

    Lu, Hongbin; Chen, Can; Wang, Zhanwen; Qu, Jin; Xu, Daqi; Wu, Tianding; Cao, Yong; Zhou, Jingyong; Zheng, Cheng; Hu, Jianzhong

    2015-09-01

    Tendon attaches to bone through a functionally graded fibrocartilage zone, including uncalcified fibrocartilage (UF), tidemark (TM) and calcified fibrocartilage (CF). This transition zone plays a pivotal role in relaxing load transfer between tendon and bone, and serves as a boundary between otherwise structurally and functionally distinct tissue types. Calcium and zinc are believed to play important roles in the normal growth, mineralization, and repair of the fibrocartilage zone of bone-tendon junction (BTJ). However, spatial distributions of calcium and zinc at the fibrocartilage zone of BTJ and their distribution-function relationship are not totally understood. Thus, synchrotron radiation-based micro X-ray fluorescence analysis (SR-μXRF) in combination with backscattered electron imaging (BEI) was employed to characterize the distributions of calcium and zinc at the fibrocartilage zone of rabbit patella-patellar tendon complex (PPTC). For the first time, the unique distributions of calcium and zinc at the fibrocartilage zone of the PPTC were clearly mapped by this method. The distributions of calcium and zinc at the fibrocartilage zone of the PPTC were inhomogeneous. A significant accumulation of zinc was exhibited in the transition region between UF and CF. The highest zinc content (3.17 times of that of patellar tendon) was found in the TM of fibrocartilage zone. The calcium content began to increase near the TM and increased exponentially across the calcified fibrocartilage region towards the patella. The highest calcium content (43.14 times of that of patellar tendon) was in the transitional zone of calcified fibrocartilage region and the patella, approximately 69 μm from the location with the highest zinc content. This study indicated, for the first time, that there is a differential distribution of calcium and zinc at the fibrocartilage zone of PPTC. These observations reveal new insights into region-dependent changes across the fibrocartilage zone of BTJ and will serve as critical benchmark parameters for current efforts in BTJ repair.

  5. Effects of a peracetic acid disinfection protocol on the biocompatibility and biomechanical properties of human patellar tendon allografts.

    PubMed

    Lomas, R J; Jennings, L M; Fisher, J; Kearney, J N

    2004-01-01

    Patellar tendon allografts, retrieved from cadaveric human donors, are widely used for replacement of damaged cruciate ligaments. In common with other tissue allografts originating from cadaveric donors, there are concerns regarding the potential for disease transmission from the donor to the recipient. Additionally, retrieval and subsequent processing protocols expose the graft to the risk of environmental contamination. For these reasons, disinfection or sterilisation protocols are necessary for these grafts before they are used clinically. A high-level disinfection protocol, utilising peracetic acid (PAA), has been developed and investigated for its effects on the biocompatibility and biomechanics of the patellar tendon allografts. PAA disinfection did not render the grafts either cytotoxic or liable to provoke an inflammatory response as assessed in vitro . However, the protocol was shown to increase the size of gaps between the tendon fibres in the matrix and render the grafts more susceptible to digestion with collagenase. Biomechanical studies of the tendons showed that PAA treatment had no effect on the ultimate tensile stress or Young's modulus of the tendons, and that ultimate strain was significantly higher in PAA treated tendons.

  6. Regional strain variations in the human patellar tendon.

    PubMed

    Pearson, Stephen J; Ritchings, Tim; Mohamed, Azlan S A

    2014-07-01

    Characteristics of localized tendon strain in vivo are largely unknown. The present study examines local tendon strain between the deep, middle, and surface structures at the proximal and distal aspects of the patellar tendon during ramped isometric contractions. Male subjects (age 28.0 ± 6.3 yr) were examined for patellar tendon excursion (anterior, midsection, and posterior) during ramped isometric voluntary contractions using real-time B-mode ultrasonography and dynamometry. Regional tendon excursion measurements were compared using an automated pixel tracking method. Strain was determined from the tendon delta length normalized to initial/resting segment length. Strain increased from 10% to 100% of force for all regions. Significantly greater mean strain was seen for the anterior proximal region compared to the posterior and mid layer of the tendon (7.5% ± 1.1% vs 3.7% ± 0.5% vs 5.5% ± 1.0%; P < 0.05). Similarly, the distal posterior region showed greater mean strain compared to the mid and anterior regions (7.9% ± 0.6% vs 5.0% ± 0.6% vs 5.4% ± 0.6%; P < 0.05). Relative changes in strain differences from 50% to 100% of force for the proximal region were greatest for the anterior to midline regions (4.6% ± 0.6% and 5.6% ± 0.6%, respectively) and those for the distal region were also greatest for the anterior to midline regions (4.4% ± 0.2% and 5.3% ± 0.2%, respectively). The largest mean strain for the proximal region was at the anterior layer (7.5% ± 1.1%) and that for the distal tendon region was at the posterior layer (7.9% ± 0.9%). This study shows significant regional differences in strain during ramped isometric contractions for the patellar tendon. Lower proximal strains in the posterior tendon compared to the anterior region may be associated with the suggestion of "stress shielding" as an etiological factor in insertional tendinopathy.

  7. A pilot study of the eccentric decline squat in the management of painful chronic patellar tendinopathy.

    PubMed

    Purdam, C R; Jonsson, P; Alfredson, H; Lorentzon, R; Cook, J L; Khan, K M

    2004-08-01

    This non-randomised pilot study investigated the effect of eccentric quadriceps training on 17 patients (22 tendons) with painful chronic patellar tendinopathy. Two different eccentric exercise regimens were used by subjects with a long duration of pain with activity (more than six months). (a) Nine consecutive patients (10 tendons; eight men, one woman; mean age 22 years) performed eccentric exercise with the ankle joint in a standard (foot flat) position. (b) Eight patients (12 tendons; five men, three women; mean age 28 years) performed eccentric training standing on a 25 degrees decline board, designed to increase load on the knee extensor mechanism. The eccentric training was performed twice daily, with three sets of 15 repetitions, for 12 weeks. Primary outcome measures were (a) 100 mm visual analogue scale (VAS), where the subject recorded the amount of pain during activity, and (b) return to previous activity. Follow up was at 12 weeks, with a further limited follow up at 15 months. Good clinical results were obtained in the group who trained on the decline board, with six patients (nine tendons) returning to sport and showing a significantly reduced amount of pain over the 12 week period. Mean VAS scores fell from 74.2 to 28.5 (p = 0.004). At 15 months, four patients (five tendons) reported satisfactory results (mean VAS 26.2). In the standard squat group the results were poor, with only one athlete returning to previous activity. Mean VAS scores in this group were 79.0 at baseline and 72.3 at 12 weeks (p = 0.144). In a small group of patients with patellar tendinopathy, eccentric squats on a decline board produced encouraging results in terms of pain reduction and return to function in the short term. Eccentric exercise using standard single leg squats in a similar sized group appeared to be a less effective form of rehabilitation in reducing pain and returning subjects to previous levels of activity.

  8. High volume ultrasound guided injections at the interface between the patellar tendon and Hoffa's body are effective in chronic patellar tendinopathy: A pilot study.

    PubMed

    Crisp, Tom; Khan, Faisal; Padhiar, Nat; Morrissey, Dylan; King, John; Jalan, Rosy; Maffulli, Nicola; Frcr, Otto Chan

    2008-01-01

    To evaluate a novel conservative management modality for patellar tendinopathy. We recruited nine patients with patellar tendinopathy who had failed conservative management and showed evidence of neovascularisation on power Doppler scanning. A high volume ultrasound guided injection at the interface between the patellar tendon and Hoffa's body. The injection contained 10 ml 0.5% Bupivacaine, 25 mg Hydrocortisone, and between 12 and 40 ml normosaline. 100 mm visual analogue scales (VAS) for pain and for function, and Victorian Institute of Sport Assessment - Patellar tendon (VISA-P) questionnaires at an average of 9 months from the injection. All but one patient (whose pain was unchanged) improved (p = 0.028). The mean improvement in function 2 weeks after injection was 58 mm on VAS (interquartile range 27 - 88, p = 0.018). The mean improvement in pain 2 weeks after injection was 56 mm on a VAS scale (interquartile range 32 - 80, p = 0.018). At a mean follow up of 9 months, an improvement of 22 points from a baseline score of 46 on the VISA-P questionnaire (100 being normal) was established. High volume injections to mechanically disrupt the neovascularisation in patellar tendinopathy are helpful in the management of this condition. Controlled trials would be warranted to investigate in a more conclusive fashion this management modality.

  9. Is the chronic painful tendinosis tendon a strong tendon?: a case study involving an Olympic weightlifter with chronic painful Jumper's knee.

    PubMed

    Gisslén, Karl; Ohberg, Lars; Alfredson, Håkan

    2006-09-01

    The chronic painful tendinosis tendon is generally considered a degenerated and weak tendon. However, this has not been scientifically verified, and is to be considered a hypothesis. We present here a case study involving a high-level Olympic weightlifter with chronic painful patellar tendinosis who started heavy-weight training very early after successful treatment with sclerosing injections. A 25-year-old super heavy-weight (+105 kg) Olympic weightlifter with 9 months duration of severe pain (prohibiting full training) in the proximal patellar tendon, where ultrasound and Doppler showed a widened tendon with structural changes and neovascularisation, was given one treatment with ultrasound and Doppler-guided injections of the sclerosing agent polidocanol. The injections targeted the neovessels posterior to the tendon. The patient was pain-free after the treatment, and already after 2-weeks he started with heavy-weight training (240 kg in deep squats) to try to qualify for the Olympics. Additional very heavy training on training camps, most often without having any discomfort or pain in the patellar tendon, resulted in Swedish records and ninth place at the European Championships 17 weeks after the treatment. Despite beating the national records, he did not qualify for the Olympics. Ultrasound and Doppler follow-ups have shown only a few remaining neovessels, and little structural tendon changes. This case questions previous theories about the weak tendinosis tendon, and stresses the importance of studies evaluating tendon strength.

  10. Infrapatellar fat pad disruption: a radiographic sign of patellar tendon rupture.

    PubMed

    Chin, Kingsley R; Sodl, Jeffrey F

    2005-11-01

    After knee trauma, radiographs showing patella alta supercede other signs that suggest patellar tendon rupture. However, without patella alta the diagnosis may be missed. A standard lateral radiograph with the knee flexed showed the infrapatellar fat pad as a dark band with a smooth contour. Our pilot study identified a disruption of the fat pad contour as a radiographic sign of tendon rupture. Two blinded reviewers independently analyzed randomly selected lateral radiographs of the knees of 14 patients with knee injuries. Seven patients had confirmed ruptures diagnosed at surgery, and the other patients had different diagnoses. There were 12 men and two women with an average age of 49 years (range, 20-81 years). One observer detected five of the seven disrupted tendons and six of the seven intact tendons. The other observer detected six of the seven disrupted tendons and all seven intact tendons. Disruption in the contour of the infrapatellar fat pad on routine lateral view radiographs was a reasonably reliable sign of patellar tendon rupture. Diagnostic accuracy should increase when used with the patient's history, physical examination, and other radiographic signs. Absence of this sign should not supersede other suggestive signs of patella tendon rupture. Diagnostic study, Level II (development of diagnostic criteria on consecutive patients--with universally applied reference "gold" standard). See the Guidelines for Authors for a complete description of levels of evidence.

  11. Tendon Adaptation to Sport-specific Loading in Adolescent Athletes.

    PubMed

    Cassel, M; Carlsohn, A; Fröhlich, K; John, M; Riegels, N; Mayer, F

    2016-02-01

    Tendon adaptation due to mechanical loading is controversially discussed. However, data concerning the development of tendon thickness in adolescent athletes is sparse. The purpose of this study was to examine possible differences in Achilles (AT) and patellar tendon (PT) thickness in adolescent athletes while considering age, gender and sport-specific loading. In 500 adolescent competitive athletes of 16 different sports and 40 recreational controls both ATs and PTs were sonographically measured. Subjects were divided into 2 age groups (< 13; ≥ 13 years) and 6 sport type categories (ball, combat, and water sports, combined disciplines, cycling, controls). In addition, 3 risk groups (low, moderate, high) were created according to the athlete's risk of developing tendinopathy. AT and PT thickness did not significantly differ between age groups (AT/PT:<13: 5.4±0.7 mm/3.6±0.5 mm;≥13: 5.3±0.7 mm/3.6±0.5 mm). In both age groups males presented higher tendon thickness than females (p<0.001). AT thickness was highest in ball sports/cyclists and lowest in controls (p≤0.002). PT thickness was greatest in water sports and lowest in controls (p=0.02). High risk athletes presented slightly higher AT thickness compared to the low risk group (p=0.03). Increased AT and PT thickness in certain sport types compared to controls supports the hypothesis of structural tendon adaptation due to sport-specific loading. © Georg Thieme Verlag KG Stuttgart · New York.

  12. [Histomorphological analyse of accelerating the fibrocartilage layer repair of patella-patellar tendon junction in rabbits by low intensity pulsed ultrasound stimulation].

    PubMed

    Zhang, Baoliang; Lü, Hongbin; Hu, Jianzhong; Xu, Daqi; Zhou, Jingyong; Wang, Ye

    2013-08-01

    To analyse the effect of low intensity pulsed ultrasound stimulation (LIPUS) on accelerating the fibrocartilage layer repair of patella-patellar tendon junction. A total of 60 mature female New Zealand white rabbits undergoing standard partial patellectomy were divided into 2 groups randomly. The control group was given comfort treatment and the treatment group was given LIPUS treatment starting from day 3 to the end of week 6 postoperatively. The scheduled time points of animal euthanization would be at week 6, week 12 and week 18 postoperatively. The patella-patellar tendon (PPT) complex would be harvested and cut into sections after decalcification for H&E staining, Safranine o/fast green staining. The thickness and gray value of fibrocartilage layer were analyzed by SANO Microscope Partner image analyzer. At week 6, week 12 and week 18 postoperatively, the fibrocartilage layer in the treatment group was significantly thicker than that in the control group (P<0.01), and the gray value of fibrocartilage layer was significantly smaller than that in the control group (P<0.01). LIPUS helps to accelerate the fibrocartilage layer repair of patella-patellar tendon junction in rabbit models.

  13. Pullout strength of bone-patellar tendon-bone allograft bone plugs: a comparison of cadaver tibia and rigid polyurethane foam.

    PubMed

    Barber, F Alan

    2013-09-01

    To compare the load-to-failure pullout strength of bone-patellar tendon-bone (BPTB) allografts in human cadaver tibias and rigid polyurethane foam blocks. Twenty BPTB allografts were trimmed creating 25 mm × 10 mm × 10 mm tibial plugs. Ten-millimeter tunnels were drilled in 10 human cadaver tibias and 10 rigid polyurethane foam blocks. The BPTB anterior cruciate ligament allografts were inserted into these tunnels and secured with metal interference screws, with placement of 10 of each type in each material. After preloading (10 N), cyclic loading (500 cycles, 10 to 150 N at 200 mm/min) and load-to-failure testing (200 mm/min) were performed. The endpoints were ultimate failure load, cyclic loading elongation, and failure mode. No difference in ultimate failure load existed between grafts inserted into rigid polyurethane foam blocks (705 N) and those in cadaver tibias (669 N) (P = .69). The mean rigid polyurethane foam block elongation (0.211 mm) was less than that in tibial bone (0.470 mm) (P = .038), with a smaller standard deviation (0.07 mm for foam) than tibial bone (0.34 mm). All BPTB grafts successfully completed 500 cycles. The rigid polyurethane foam block showed less variation in test results than human cadaver tibias. Rigid polyurethane foam blocks provide an acceptable substitute for human cadaver bone tibia for biomechanical testing of BPTB allografts and offer near-equivalent results. Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  14. Eccentric training as a new approach for rotator cuff tendinopathy: Review and perspectives

    PubMed Central

    Camargo, Paula R; Alburquerque-Sendín, Francisco; Salvini, Tania F

    2014-01-01

    Excessive mechanical loading is considered the major cause of rotator cuff tendinopathy. Although tendon problems are very common, they are not always easy to treat. Eccentric training has been proposed as an effective conservative treatment for the Achilles and patellar tendinopathies, but less evidence exists about its effectiveness for the rotator cuff tendinopathy. The mechanotransduction process associated with an adequate dose of mechanical load might explain the beneficial results of applying the eccentric training to the tendons. An adequate load increases healing and an inadequate (over or underuse) load can deteriorate the tendon structure. Different eccentric training protocols have been used in the few studies conducted for people with rotator cuff tendinopathy. Further, the effects of the eccentric training for rotator cuff tendinopathy were only evaluated on pain, function and strength. Future studies should assess the effects of the eccentric training also on shoulder kinematics and muscle activity. Individualization of the exercise prescription, comprehension and motivation of the patients, and the establishment of specific goals, practice and efforts should all be considered when prescribing the eccentric training. In conclusion, eccentric training should be used aiming improvement of the tendon degeneration, but more evidence is necessary to establish the adequate dose-response and to determine long-term follow-up effects. PMID:25405092

  15. Australian football players' Achilles tendons respond to game loads within 2 days: an ultrasound tissue characterisation (UTC) study.

    PubMed

    Rosengarten, Samuel D; Cook, Jill L; Bryant, Adam L; Cordy, Justin T; Daffy, John; Docking, Sean I

    2015-02-01

    The Achilles tendon is a tissue that responds to mechanical loads at a molecular and cellular level. In vitro and in vivo studies have shown that the expression of anabolic and/or catabolic proteins can change within hours of loading and return to baseline levels within 72 h. These biochemical changes have not been correlated with changes in whole tendon structure on imaging. We examined the nature and temporal sequence of changes in Achilles tendon structure in response to competitive game loads in elite Australian football players. Elite male Australian football players with no history of Achilles tendinopathy were recruited. Achilles tendon structure was quantified using ultrasound tissue characterisation (UTC) imaging, a valid and reliable measure of intratendinous structure, the day prior to the match (day 0), and then reimaged on days 1, 2 and 4 postgame. Of the 18 participants eligible for this study, 12 had no history of tendinopathy (NORM) and 6 had a history of patellar or hamstring tendinopathy (TEN). Differences in baseline UTC echopattern were observed between the NORM and TEN groups, with the Achilles of the TEN group exhibiting altered UTC echopattern, consistent with a slightly disorganised tendon structure. In the NORM group, a significant reduction in echo-type I (normal tendon structure) was seen on day 2 (p=0.012) that returned to baseline on day 4. There was a transient change in UTC echopattern in the Achilles tendon as a result of an Australian football game in individuals without a history of lower limb tendinopathy. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  16. [Use of Ultrasound in the Follow-up of Professional Athletes Receiving Conservative Treatment of Patellar Tendon Enthesiopathy].

    PubMed

    Guo, Li-juan; Cui, Li-gang; Li, Yu-mei; Liao, Li-ping; Song, Lin

    2015-10-01

    To investigate the role of high-frequency ultrasound (HFUS) in evaluating in the effectiveness of conservative treatment for professional athletes with patellar tendon enthesiopathy. According to different treatment intensities, 24 professional athletes with patellar tendon enthesiopathy were randomly divided into painless group, slightly-painful group and extremely-painful group. Then changes of the HFUS findings [including ranges of two-dimensional diseases and blood conditions by Color Doppler Flow Imaging (CDFI)] of patellar tendon before and after the treatment were recorded. The results were also compared with conventional clinical treatment evaluations. After two courses of treatment,the percentage of athletes whose pain was resolved or disappeared was 37.5% in painless group, 87.5% in slightly-painful group, and 62.5% in extremely-painful group. The pain score was 4.50 ± 2.07, 4.88 ± 1.13, and 6.13 ± 1.55 in painless group,slightly-painful group,and extremely-painful group, respectively,before treatment and 4.88 ± 2.17, 3.00 ± 1.77,and 5.13 ± 2.36 after treatment. The average pain score remarkably decreased in the slightly-painful group and extremely-painful group,and such difference was statistically significant in the slightly-pain group (P<0.05). The effective rate (defined as thinner patellar,decreased hypoecho area and fewer blood distribution in the lesion) was 38%, 50%, and 62% in the painless group, slightly-painful group,and extremely-painful group, and the rates in the slightly-painful group and extremely-painful group were significantly higher than that in painless group (both P<0.05). HFUS can display the ultrasonographic changes of patellar tendon enthesiopathy after conservative treatments in an objective and quantitative manner. Compared with conventional clinical evaluations, it can more accurately reflect the disease recovery status.

  17. Biomechanical properties of patellar and hamstring graft tibial fixation techniques in anterior cruciate ligament reconstruction: experimental study with roentgen stereometric analysis.

    PubMed

    Adam, Frank; Pape, Dietrich; Schiel, Karin; Steimer, Oliver; Kohn, Dieter; Rupp, Stefan

    2004-01-01

    Reliable fixation of the soft hamstring grafts in ACL reconstruction has been reported as problematic. The biomechanical properties of patellar tendon (PT) grafts fixed with biodegradable screws (PTBS) are superior compared to quadrupled hamstring grafts fixed with BioScrew (HBS) or Suture-Disc fixation (HSD). Controlled laboratory study with roentgen stereometric analysis (RSA). Ten porcine specimens were prepared for each group. In the PT group, the bone plugs were fixed with a 7 x 25 mm BioScrew. In the hamstring group, four-stranded tendon grafts were anchored within a tibial tunnel of 8 mm diameter either with a 7 x 25 mm BioScrew or eight polyester sutures knotted over a Suture-Disc. The grafts were loaded stepwise, and micromotion of the graft inside the tibial tunnel was measured with RSA. Hamstring grafts failed at lower loads (HBS: 536 N, HSD 445 N) than the PTBS grafts (658 N). Stiffness in the PTBS group was much greater compared to the hamstring groups (3500 N/mm versus HBS = 517 N/mm and HSD = 111 N/mm). Irreversible graft motion after graft loading with 200 N was measured at 0.03 mm (PTBS), 0.38mm (HBS), and 1.85mm (HSD). Elasticity for the HSD fixation was measured at 0.67 mm at 100 N and 1.32 mm at 200 N load. Hamstring graft fixation with BioScrew and Suture-Disc displayed less stiffness and early graft motion compared to PTBS fixation. Screw fixation of tendon grafts is superior to Suture-Disc fixation with linkage material since it offers greater stiffness and less graft motion inside the tibial tunnel. Our results revealed graft motion for hamstring fixation with screw or linkage material at loads that occur during rehabilitation. This, in turn, may lead to graft laxity.

  18. Tendinous tissue properties after short- and long-term functional overload: Differences between controls, 12 weeks and 4 years of resistance training.

    PubMed

    Massey, G J; Balshaw, T G; Maden-Wilkinson, T M; Folland, J P

    2018-04-01

    The potential for tendinous tissues to adapt to functional overload, especially after several years of exposure to heavy-resistance training, is largely unexplored. This study compared the morphological and mechanical characteristics of the patellar tendon and knee extensor tendon-aponeurosis complex between young men exposed to long-term (4 years; n = 16), short-term (12 weeks; n = 15) and no (untrained controls; n = 39) functional overload in the form of heavy-resistance training. Patellar tendon cross-sectional area, vastus lateralis aponeurosis area and quadriceps femoris volume, plus patellar tendon stiffness and Young's modulus, and tendon-aponeurosis complex stiffness, were quantified with MRI, dynamometry and ultrasonography. As expected, long-term trained had greater muscle strength and volume (+58% and +56% vs untrained, both P < .001), as well as a greater aponeurosis area (+17% vs untrained, P < .01), but tendon cross-sectional area (mean and regional) was not different between groups. Only long-term trained had reduced patellar tendon elongation/strain over the whole force/stress range, whilst both short-term and long-term overload groups had similarly greater stiffness/Young's modulus at high force/stress (short-term +25/22%, and long-term +17/23% vs untrained; all P < .05). Tendon-aponeurosis complex stiffness was not different between groups (ANOVA, P = .149). Despite large differences in muscle strength and size, years of resistance training did not induce tendon hypertrophy. Both short-term and long-term overload demonstrated similar increases in high-force mechanical and material stiffness, but reduced elongation/strain over the whole force/stress range occurred only after years of overload, indicating a force/strain specific time-course to these adaptations. © 2017 Scandinavian Physiological Society. Published by John Wiley & Sons Ltd.

  19. Platelet-rich plasma in tendon-related disorders: results and indications.

    PubMed

    Filardo, Giuseppe; Di Matteo, Berardo; Kon, Elizaveta; Merli, Giulia; Marcacci, Maurilio

    2016-09-24

    Platelet-rich plasma (PRP) is currently the most exploited strategy in the clinical practice to provide a regenerative stimulus for tendon healing. The aim of the present study was to systematically review the available evidence on the treatment of the main tendon disorders where PRP is currently applied. A systematic review of the literature was performed on the use of PRP as a treatment for tendinopathies focusing on the following sites: Achilles tendon, patellar tendon, rotator cuff tendons, and lateral elbow tendons. The following inclusion criteria for relevant articles were used: clinical trials written in English language up to 21 June 2016 on the use of PRP in the conservative or surgical treatment of the aforementioned tendinopathies. The research identified the following clinical trials dealing with the application of PRP in the selected tendons: 19 papers on patellar tendon (6 being RCTs: 4 dealing with PRP conservative application and 2 surgical), 24 papers on Achilles tendon (4 RCTs: 3 conservative and 1 surgical), 29 on lateral elbow tendons (17 RCTs, all conservative), and 32 on rotator cuff (22 RCTs: 18 surgical and 3 conservative). Patellar tendons seem to benefit from PRP injections, whereas in the Achilles tendon, PRP application is not indicated neither as a conservative approach nor as a surgical augmentation. Lateral elbow tendinopathy showed an improvement in most of the high-level studies, but the lack of proven superiority with respect to the more simple whole-blood injections still questions its use in the clinical practice. With regard to rotator cuff pathology, the vast majority of surgical RCTs documented a lack of beneficial effects, whereas there is still inconclusive evidence concerning its conservative application in rotator cuff disorders. Systematic review of level I-IV trials, Level IV.

  20. Quadriceps tendon autograft for arthroscopic knee ligament reconstruction: use it now, use it often.

    PubMed

    Sheean, Andrew J; Musahl, Volker; Slone, Harris S; Xerogeanes, John W; Milinkovic, Danko; Fink, Christian; Hoser, Christian

    2018-04-28

    Traditional bone-patellar tendon-bone and hamstring tendon ACL grafts are not without limitations. A growing body of anatomic, biomechanical and clinical data has demonstrated the utility of quadriceps tendon autograft in arthroscopic knee ligament reconstruction. The quadriceps tendon autograft provides a robust volume of tissue that can be reliably harvested, mitigating the likelihood of variably sized grafts and obviating the necessity of allograft augmentation. Modern, minimally invasive harvest techniques offer the advantages of low rates of donor site morbidity and residual extensor mechanism strength deficits. New data suggest that quadriceps tendon autograft may possess superior biomechanical characteristics when compared with bone-patella tendon-bone (BPTB) autograft. However, there have been very few direct, prospective comparisons between the clinical outcomes associated with quadriceps tendon autograft and other autograft options (eg, hamstring tendon and bone-patellar tendon-bone). Nevertheless, quadriceps tendon autograft should be one of the primary options in any knee surgeon's armamentarium. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  1. The paratenon contributes to scleraxis-expressing cells during patellar tendon healing.

    PubMed

    Dyment, Nathaniel A; Liu, Chia-Feng; Kazemi, Namdar; Aschbacher-Smith, Lindsey E; Kenter, Keith; Breidenbach, Andrew P; Shearn, Jason T; Wylie, Christopher; Rowe, David W; Butler, David L

    2013-01-01

    The origin of cells that contribute to tendon healing, specifically extrinsic epitenon/paratenon cells vs. internal tendon fibroblasts, is still debated. The purpose of this study is to determine the location and phenotype of cells that contribute to healing of a central patellar tendon defect injury in the mouse. Normal adult patellar tendon consists of scleraxis-expressing (Scx) tendon fibroblasts situated among aligned collagen fibrils. The tendon body is surrounded by paratenon, which consists of a thin layer of cells that do not express Scx and collagen fibers oriented circumferentially around the tendon. At 3 days following injury, the paratenon thickens as cells within the paratenon proliferate and begin producing tenascin-C and fibromodulin. These cells migrate toward the defect site and express scleraxis and smooth muscle actin alpha by day 7. The thickened paratenon tissue eventually bridges the tendon defect by day 14. Similarly, cells within the periphery of the adjacent tendon struts express these markers and become disorganized. Cells within the defect region show increased expression of fibrillar collagens (Col1a1 and Col3a1) but decreased expression of tenogenic transcription factors (scleraxis and mohawk homeobox) and collagen assembly genes (fibromodulin and decorin). By contrast, early growth response 1 and 2 are upregulated in these tissues along with tenascin-C. These results suggest that paratenon cells, which normally do not express Scx, respond to injury by turning on Scx and assembling matrix to bridge the defect. Future studies are needed to determine the signaling pathways that drive these cells and whether they are capable of producing a functional tendon matrix. Understanding this process may guide tissue engineering strategies in the future by stimulating these cells to improve tendon repair.

  2. Accumulation of oxidized LDL in the tendon tissues of C57BL/6 or apolipoprotein E knock-out mice that consume a high fat diet: potential impact on tendon health.

    PubMed

    Grewal, Navdeep; Thornton, Gail M; Behzad, Hayedeh; Sharma, Aishwariya; Lu, Alex; Zhang, Peng; Reid, W Darlene; Granville Alex Scott, David J

    2014-01-01

    Clinical studies have suggested an association between dyslipidemia and tendon injuries or chronic tendon pain; the mechanisms underlying this association are not yet known. The objectives of this study were (1) to evaluate the impact of a high fat diet on the function of load-bearing tendons and on the distribution in tendons of oxidized low density lipoprotein (oxLDL), and (2) to examine the effect of oxLDL on tendon fibroblast proliferation and gene expression. Gene expression (Mmp2, Tgfb1, Col1a1, Col3a1), fat content (Oil Red O staining), oxLDL levels (immunohistochemistry) and tendon biomechanical properties were examined in mice (C57Bl/6 or ApoE -/-) receiving a standard or a high fat diet. Human tendon fibroblast proliferation and gene expression (COL1A1, COL3A1, MMP2) were examined following oxLDL exposure. In both types of mice (C57Bl/6 or ApoE -/-), consumption of a high fat diet led to a marked increase in oxLDL deposition in the load-bearing extracellular matrix of the tendon. The consumption of a high fat diet also reduced the failure stress and load of the patellar tendon in both mouse types, and increased Mmp2 expression. ApoE -/- mice exhibited more pronounced reductions in tendon function than wild-type mice, and decreased expression of Col1a1 compared to wild type mice. Human tendon fibroblasts responded to oxLDL by increasing their proliferation and their mRNA levels of MMP2, while decreasing their mRNA levels for COL1A1 and COL3A1. The consumption of a high fat diet resulted in deleterious changes in tendon function, and these changes may be explained in part by the effects of oxLDL, which induced a proliferative, matrix-degrading phenotype in human tenocytes.

  3. Acute traumatic rupture of the patellar tendon in pediatric population: Case series and review of the literature.

    PubMed

    Ali Yousef, Mohamed Abdelhamid; Rosenfeld, Scott

    2017-11-01

    Intact knee extensor mechanism is required for the normal function of the lower extremity. Patellar tendon rupture is a relatively rare injury with peak age incidence around 40 years and usually occurs midsubstance. The occurrence of pure patellar tendon rupture without bony avulsion is an extremely rare injury in the pediatric population with few cases reported in the literature with limited information regarding frequency, complications, and outcomes in children. However, due to increased participation in sports and high-energy recreational activities during childhood, the frequency of such injuries has progressively increased. To evaluate the frequency of pediatric patellar tendon rupture injuries and describe the radiological findings, treatment modalities, and outcome of such injuries. Demographic and clinical data on a series of patients who sustained patellar tendon rupture were reviewed. These data included age at time of injury, sex, laterality, mechanism of injury, associated injuries, complications, presence or absence of Osgood-Schlatter disease, diagnostic imaging such as plain radiographs and magnetic resonance images (MRI), surgical technique, method of fixation, period of postoperative immobilization, total duration of physiotherapy, time to return to sports activities and follow-up duration. Insall-Salvati ratio was calculated on the preoperative lateral x-ray. The functional outcome was evaluated with regard to final knee active range of motion (AROM), manual quadriceps muscle testing, and presence or the absence of terminal extension lag. Clinical outcome rating using knee society score (KSS) was performed and functional outcome was further classified according to the calculated score. Five male patients with patellar tendon rupture (7%) were identified among 71 pediatric patients who sustained acute traumatic injury of the knee extensor mechanism. The mean age at the time of injury was 13.6 years (range: 12-15 years). The injury occurred in relation to sports activities in 4 patients. Osteogenesis imperfecta and Osgood-Schlatter disease were identified in 2 patients. High riding patella is the hallmark diagnostic sign detected in plain x-ray with preoperative Insall-Salvati ratio ranged from 1.7 to 2.5. Three patients had pure soft tissue avulsion distally from the proximal tibia, 1 patient had pure soft tissue avulsion proximally from the inferior patellar pole, and 1 patient with midsubstance tendinous disruption. No associated intra-articular lesions were identified. Suture bridge double row technique, transpatellar suturing, and transosseous suturing through the proximal tibia were used for patellar tendon reinsertion. After a mean follow-up period of 18. 4 weeks (range: 10-30 weeks), patients achieved AROM ranging from 0 to 120° to 0-137° without terminal extension lag. The mean time to return to sports activity was 22 weeks (range: 13-30 weeks). Quadriceps muscle strength was 5/5 at the final follow-up visit in all patients; however, relative muscle atrophy was noted in comparison to the other side in one patient. The mean KSS was 91.8 points (range: 79-100 points) with excellent outcome in 4 patients and good outcome in 1 patient. Patellar tendon rupture is rare in the pediatric population and represents 7% of pediatric patients who sustained acute traumatic injury of the knee extensor mechanism. Ruptures may occur midsubstance, or from proximal or distal insertions. High riding patella is the hallmark diagnostic sign for such injury. Although rare, it is considered a serious injury that necessitates early diagnosis and surgical intervention. Functional range of motion was obtained in all patients with different modalities of treatment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Risk of Revision Was Not Reduced by a Double-bundle ACL Reconstruction Technique: Results From the Scandinavian Registers.

    PubMed

    Aga, Cathrine; Kartus, Jüri-Tomas; Lind, Martin; Lygre, Stein Håkon Låstad; Granan, Lars-Petter; Engebretsen, Lars

    2017-10-01

    Double-bundle anterior cruciate ligament (ACL) reconstruction has demonstrated improved biomechanical properties and moderately better objective outcomes compared with single-bundle reconstructions. This could make an impact on the rerupture rate and reduce the risk of revisions in patients undergoing double-bundle ACL reconstruction compared with patients reconstructed with a traditional single-bundle technique. The National Knee Ligament Registers in Scandinavia provide information that can be used to evaluate the revision outcome after ACL reconstructions. The purposes of the study were (1) to compare the risk of revision between double-bundle and single-bundle reconstructions, reconstructed with autologous hamstring tendon grafts; (2) to compare the risk of revision between double-bundle hamstring tendon and single-bundle bone-patellar tendon-bone autografts; and (3) to compare the hazard ratios for the same two research questions after Cox regression analysis was performed. Data collection of primary ACL reconstructions from the National Knee Ligament Registers in Denmark, Norway, and Sweden from July 1, 2005, to December 31, 2014, was retrospectively analyzed. A total of 60,775 patients were included in the study; 994 patients were reconstructed with double-bundle hamstring tendon grafts, 51,991 with single-bundle hamstring tendon grafts, and 7790 with single-bundle bone-patellar tendon-bone grafts. The double-bundle ACL-reconstructed patients were compared with the two other groups. The risk of revision for each research question was detected by the risk ratio, hazard ratio, and the corresponding 95% confidence intervals. Kaplan-Meier analysis was used to estimate survival at 1, 2, and 5 years for the three different groups. Furthermore, a Cox proportional hazard regression model was applied and the hazard ratios were adjusted for country, age, sex, meniscal or chondral injury, and utilized fixation devices on the femoral and tibial sides. There were no differences in the crude risk of revision between the patients undergoing the double-bundle technique and the two other groups. A total of 3.7% patients were revised in the double-bundle group (37 of 994 patients) versus 3.8% in the single-bundle hamstring tendon group (1952 of 51,991; risk ratio, 1.01; 95% confidence interval (CI), 0.73-1.39; p = 0.96), and 2.8% of the patients were revised in the bone-patellar tendon-bone group (219 of the 7790 bone-patellar tendon-bone patients; risk ratio, 0.76; 95% CI, 0.54-1.06; p = 0.11). Cox regression analysis with adjustment for country, age, sex, menisci or cartilage injury, and utilized fixation device on the femoral and tibial sides, did not reveal any further difference in the risk of revision between the single-bundle hamstring tendon and double-bundle hamstring tendon groups (hazard ratio, 1.18; 95% CI, 0.85-1.62; p = 0.33), but the adjusted hazard ratio showed a lower risk of revision in the single-bundle bone-patellar tendon-bone group compared with the double-bundle group (hazard ratio, 0.62; 95% CI, 0.43-0.90; p = 0.01). Comparisons of the graft revision rates reported separately for each country revealed that double-bundle hamstring tendon reconstructions in Sweden had a lower hazard ratio compared with the single-bundle hamstring tendon reconstructions (hazard ratio, 1.00 versus 1.89; 95% CI, 1.09-3.29; p = 0.02). Survival at 5 years after index surgery was 96.0% for the double-bundle group, 95.4% for the single-bundle hamstring tendon group, and 97.0% for the single-bundle bone-patellar tendon-bone group. Based on the data from all three national registers, the risk of revision was not influenced by the reconstruction technique in terms of using single- or double-bundle hamstring tendons, although national differences in survival existed. Using bone-patellar tendon-bone grafts lowered the risk of revision compared with double-bundle hamstring tendon grafts. These findings should be considered when deciding what reconstruction technique to use in ACL-deficient knees. Future studies identifying the reasons for graft rerupture in single- and double-bundle reconstructions would be of interest to understand the findings of the present study. Level III, therapeutic study.

  5. Patellar tendon properties distinguish elite from non-elite soccer players and are related to peak horizontal but not vertical power.

    PubMed

    Murtagh, Conall F; Stubbs, Michael; Vanrenterghem, Jos; O'Boyle, Andrew; Morgans, Ryland; Drust, Barry; Erskine, Robert M

    2018-06-02

    To investigate potential differences in patellar tendon properties between elite and non-elite soccer players, and to establish whether tendon properties were related to power assessed during unilateral jumps performed in different directions. Elite (n = 16; age 18.1 ± 1.0 years) and non-elite (n = 13; age 22.3 ± 2.7 years) soccer players performed vertical, horizontal-forward and medial unilateral countermovement jumps (CMJs) on a force plate. Patellar tendon (PT) cross-sectional area, elongation, strain, stiffness, and Young's modulus (measured at the highest common force interval) were assessed with ultrasonography and isokinetic dynamometry. Elite demonstrated greater PT elongation (6.83 ± 1.87 vs. 4.92 ± 1.88 mm, P = 0.011) and strain (11.73 ± 3.25 vs. 8.38 ± 3.06%, P = 0.009) than non-elite soccer players. Projectile range and peak horizontal power during horizontal-forward CMJ correlated positively with tendon elongation (r = 0.657 and 0.693, P < 0.001) but inversely with Young's modulus (r = - 0.376 and - 0.402; P = 0.044 and 0.031). Peak medial power during medial CMJ correlated positively with tendon elongation (r = 0.658, P < 0.001) but inversely with tendon stiffness (r = - 0.368, P = 0.050). Not only does a more compliant patellar tendon appear to be an indicator of elite soccer playing status but it may also facilitate unilateral horizontal-forward and medial, but not vertical CMJ performance. These findings should be considered when prescribing talent selection and development protocols related to direction-specific power in elite soccer players.

  6. The effect of freeze-thawing on magnetic resonance imaging T2* of freshly harvested bovine patellar tendon

    PubMed Central

    Pownder, Sarah L.; Shah, Parina H.; Potter, Hollis G.

    2015-01-01

    Background Analysis of fresh specimens in research studies is ideal; however, it is often necessary to freeze samples for evaluation at a later time. Limited evaluation of the effect of freeze-thawing of tendon tissue samples on inherent magnetic resonance imaging (MRI) parameters, such as ultrashort echo time (UTE) T2* values, have been performed to date. Methods This study performed UTE MRI on 14 bovine patellar tendons at harvest and after four consecutive freeze-thaw cycles. Results Results demonstrated a small but significant reduction (12%) in tendon T2* values after the first freeze thaw cycle, but not after successive cycles. Tendons from juvenile animals with open physis had a significant reduction of T2* following a single freeze thaw cycle, P<0.0001. Conclusions The results of this study emphasize the importance of using uniform tendon storage protocols when using UTE MRI in preclinical models. PMID:26029639

  7. Use of platelet-rich plasma for patellar tendon and medial collateral ligament injuries: best current clinical practice.

    PubMed

    Andia, Isabel; Maffulli, Nicola

    2015-02-01

    Platelet-rich plasmas (PRPs) are complex molecular therapies prepared from the patient's own blood through minimal manipulation. Clinical studies examining the efficacy of PRPs to manage patellar tendinopathy and medial collateral ligament (MCL) injuries have been reviewed. We found three controlled trials, two of them randomized, and seven case series in the management of patellar tendinopathy. In addition, three other randomized studies showed that PRPs help to regenerate the patellar tendon harvest site for anterior cruciate ligament reconstruction and to reduce patellar donor site morbidity. On the other hand, the use of PRP in MCL injuries is reported in a single case study. Seven of the 11 studies used leukocyte and PRP which was buffered in four studies. Seven of the 11 studies applied two or three injections. Given the heterogeneity of PRP protocols and the paucity of high-quality data, the most effective approach to guide clinical decisions regarding patellar tendinopathy cannot be deduced from the present published studies. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  8. Decorin and biglycan are necessary for maintaining collagen fibril structure, fiber realignment, and mechanical properties of mature tendons.

    PubMed

    Robinson, Kelsey A; Sun, Mei; Barnum, Carrie E; Weiss, Stephanie N; Huegel, Julianne; Shetye, Snehal S; Lin, Linda; Saez, Daniel; Adams, Sheila M; Iozzo, Renato V; Soslowsky, Louis J; Birk, David E

    2017-12-01

    The small leucine-rich proteoglycans (SLRPs), decorin and biglycan, are key regulators of collagen fibril and matrix assembly. The goal of this work was to elucidate the roles of decorin and biglycan in tendon homeostasis. Our central hypothesis is that decorin and biglycan expression in the mature tendon would be critical for the maintenance of the structural and mechanical properties of healthy tendons. Defining the function(s) of these SLRPs in tendon homeostasis requires that effects in the mature tendon be isolated from their influence on development. Thus, we generated an inducible knockout mouse model that permits genetic ablation of decorin and biglycan expression in the mature tendon, while maintaining normal expression during development. Decorin and biglycan expression were knocked out in the mature patellar tendon with the subsequent turnover of endogenous SLRPs deposited prior to induction. The acute absence of SLRP expression was associated with changes in fibril structure with a general shift to larger diameter fibrils in the compound knockout tendons, together with fibril diameter heterogeneity. In addition, tendon mechanical properties were altered. Compared to wild-type controls, acute ablation of both genes resulted in failure of the tendon at lower loads, decreased stiffness, a trend towards decreased dynamic modulus, as well as a significant increase in percent relaxation and tissue viscosity. Collagen fiber realignment was also increased with a delayed and slower in response to load in the absence of expression. These structural and functional changes in response to an acute loss of decorin and biglycan expression in the mature tendon demonstrate a significant role for these SLRPs in adult tendon homeostasis. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Effect of eccentric exercise on the healing process of injured patellar tendon in rats.

    PubMed

    Nakamura, Kenichi; Kitaoka, Katsuhiko; Tomita, Katsuro

    2008-07-01

    Earlier studies have reported positive results from eccentric training in patients with tendon disorders. The reasons for the beneficial clinical effects of eccentric training are not known. Vascularization followed by regression of the vasculature enhances the healing response of injured tendons. Eccentric exercise induces a more beneficial healing response than concentric exercise. Sixty rats with patellar tendon injuries were divided into three groups: nonexercise controls (group N; n = 20); concentric exercise group (group C; n = 20); eccentric exercise group (group E; n = 20). Each rat was taught to run uphill or downhill for 14 days. Patellar tendons were removed 1, 4, 7, 10, and 14 days following injury. Vascular endothelial growth factor (VEGF), angiopoietin-1, and angiopoietin-2 were measured by reverse transcription polymerase chain reaction. In group C, VEGF mRNA was increased 1 and 4 days following injury but was decreased on days 7, 10, and 14. In group E, VEGF mRNA was elevated only on day 1. In group N, VEGF mRNA remained at a low level throughout all 14 days. The angiopoietin-2/angiopoietin-1 ratio was higher for group C than for group E. In the presence of VEGF, angiopoietin-1 promotes vessel stability, whereas angiopoietin-2 has the opposite effect. Eccentric exercise contributes to stabilized angiogenesis during the early phase of tendon injury. Conversely, concentric exercise, which induces destabilized angiogenesis, leads to a delayed healing response. Initiation of eccentric exercise immediately after tendon injury may help improve healing by reducing vascularity.

  10. Diabetes Mellitus Alters the Mechanical Properties of the Native Tendon in an Experimental Rat Model

    PubMed Central

    Fox, Alice J. S.; Bedi, Asheesh; Deng, Xiang-Hua; Ying, Liang; Harris, Paul E.; Warren, Russell F.; Rodeo, Scott A.

    2017-01-01

    The purpose of this study was to determine the effect of the diabetic phenotype on the mechanical properties of the native patellar tendon and its enthesis. Diabetes was induced via intraperitoneal injection of streptozotocin in Lewis rats. Control (n = 18) and diabetic animals(n = 20) were killed at 12 and 19 days for analysis. Statistical comparisons were performed using Student’s t-tests and a two-tailed Fisher test with significance set at p < 0.05. Pre- and post-injection intraperitoneal glucose tolerance tests demonstrated significant impairment of glycemic control in the diabetic compared to control animals (p = 0.001). Mean serum hemoglobin A1c levels at 19 days was 10.6 ± 2.7% and 6.0 ± 1.0% for the diabetic and control groups, respectively (p = 0.0001). Fifteen of sixteen diabetic animals demonstrated intrasubstance failure of the patellar tendon, while only 7 of 14 control specimens failed within the tendon substance. The Young’s modulus of the diabetic tendon was significantly lower than control specimens by 19 days post-induction (161 ± 10 N m−2 compared to 200 ± 46 N m−2, respectively) (p = 0.02). The metabolic condition of poorly controlled diabetes negatively affects the mechanical properties of the native patellar tendon. These altered structural properties may predispose diabetic patients to a greater risk of tendinopathy and/or traumatic rupture. PMID:21246619

  11. High volume image-guided Injections for patellar tendinopathy: a combined retrospective and prospective case series.

    PubMed

    Morton, Sarah; Chan, Otto; King, John; Perry, David; Crisp, Tom; Maffulli, Nicola; Morrissey, Dylan

    2014-04-01

    the aim was to quantify the effect of a novel high volume-image guided injection (HVIGI) technique for recalcitrant patellar tendinopathy (PT). twenty patients (8 prospective; 12 retrospective) with ultrasonographically confirmed proximal PT were recruited. A HVIGI under ultra-sound guidance of 10 ml 0.5% Bupivacaine, 25 mg Hydrocortisone and 30 ml normal saline at the interface of the patellar tendon and Hoffa's fat pad was administered. A standardised eccentric loading rehabilitation protocol was prescribed. the VISA-P score improved from 45.0 to 64.0 (p<0.01) for all subjects, likely to be clinically significant. There was no statistically significant difference between the increase in the retrospective group of 19.9 (± 23.5) and the prospective of 16.4 (± 11.3) p = 0.7262.5% of prospective subjects agreed that they had significantly improved, with 37.5% returning to sport within 12 weeks. HVIGI should be considered in the management of recalcitrant PT. Randomised controlled trials are warranted.

  12. Implementation of an iPhone wireless accelerometer application for the quantification of reflex response.

    PubMed

    LeMoyne, Robert; Mastroianni, Timothy; Grundfest, Warren; Nishikawa, Kiisa

    2013-01-01

    The patellar tendon reflex represents an inherent aspect of the standard neurological evaluation. The features of the reflex response provide initial perspective regarding the status of the nervous system. An iPhone wireless accelerometer application integrated with a potential energy impact pendulum attached to a reflex hammer has been successfully developed, tested, and evaluated for quantifying the patellar tendon reflex. The iPhone functions as a wireless accelerometer platform. The wide coverage range of the iPhone enables the quantification of reflex response samples in rural and remote settings. The iPhone has the capacity to transmit the reflex response acceleration waveform by wireless transmission through email. Automated post-processing of the acceleration waveform provides feature extraction of the maximum acceleration of the reflex response ascertained after evoking the patellar tendon reflex. The iPhone wireless accelerometer application demonstrated the utility of the smartphone as a biomedical device, while providing accurate and consistent quantification of the reflex response.

  13. Accumulation of Oxidized LDL in the Tendon Tissues of C57BL/6 or Apolipoprotein E Knock-Out Mice That Consume a High Fat Diet: Potential Impact on Tendon Health

    PubMed Central

    Grewal, Navdeep; Thornton, Gail M.; Behzad, Hayedeh; Sharma, Aishwariya; Lu, Alex; Zhang, Peng; Reid, W. Darlene; Granville, David J.; Scott, Alex

    2014-01-01

    Objective Clinical studies have suggested an association between dyslipidemia and tendon injuries or chronic tendon pain; the mechanisms underlying this association are not yet known. The objectives of this study were (1) to evaluate the impact of a high fat diet on the function of load-bearing tendons and on the distribution in tendons of oxidized low density lipoprotein (oxLDL), and (2) to examine the effect of oxLDL on tendon fibroblast proliferation and gene expression. Methods Gene expression (Mmp2, Tgfb1, Col1a1, Col3a1), fat content (Oil Red O staining), oxLDL levels (immunohistochemistry) and tendon biomechanical properties were examined in mice (C57Bl/6 or ApoE -/-) receiving a standard or a high fat diet. Human tendon fibroblast proliferation and gene expression (COL1A1, COL3A1, MMP2) were examined following oxLDL exposure. Results In both types of mice (C57Bl/6 or ApoE -/-), consumption of a high fat diet led to a marked increase in oxLDL deposition in the load-bearing extracellular matrix of the tendon. The consumption of a high fat diet also reduced the failure stress and load of the patellar tendon in both mouse types, and increased Mmp2 expression. ApoE -/- mice exhibited more pronounced reductions in tendon function than wild-type mice, and decreased expression of Col1a1 compared to wild type mice. Human tendon fibroblasts responded to oxLDL by increasing their proliferation and their mRNA levels of MMP2, while decreasing their mRNA levels for COL1A1 and COL3A1. Conclusion The consumption of a high fat diet resulted in deleterious changes in tendon function, and these changes may be explained in part by the effects of oxLDL, which induced a proliferative, matrix-degrading phenotype in human tenocytes. PMID:25502628

  14. Hyaluronic acid injections protect patellar tendon from detraining-associated damage.

    PubMed

    Frizziero, Antonio; Salamanna, Francesca; Giavaresi, Gianluca; Ferrari, Andrea; Martini, Lucia; Marini, Marina; Veicsteinas, Arsenio; Maffulli, Nicola; Masiero, Stefano; Fini, Milena

    2015-09-01

    Having previously demonstrated that detraining affects patellar tendon (PT) proteoglycan content and collagen fiber organization, we undertook the present study with two aims: to improve knowledge on the adaptation of PT and its enthesis to detraining from a histological and histomorphometric point of view, and to investigate the hypothesis that repeated peri-patellar injections of hyaluronic acid (HA) on detrained PT may reduce and limit detrained associated-damage. Twenty-four male Sprague-Dawley rats were divided into 3 groups: Untrained (n=6), Trained (n=6) (10 wks-treadmill) and Detrained (n=12). In the detrained rats, the left tendon was untreated while the right tendon received repeated peri-patellar injections of either HA or saline (NaCl). Structure and morphology of PTs (modified Movin score, tear density, collagen type I and III) and enthesis (cell morphology, chondrocyte cluster formation, tidemark integrity, matrix staining and vascularization) were evaluated. The left PT and enthesis of the Detrained groups showed altered structure and morphology with the highest Movin score values, the highest percentage of collagen III and the lowest of collagen I; the lowest score values were observed in the Trained and Detrained-HA groups. Detrained-NaCl PTs showed the highest collagen III and the lowest collagen I values with respect to Detrained-HA PTs. This study strengthens previously published data showing the alteration in tendon and enthesis morphology due to discontinuation of training, and provides new data showing that treatment with HA is effective in the maintenance of the structural properties of PT and enthesis in Detrained rats. Such beneficial effects could play a significant role in the management of conservative and rehabilitation strategies in athletes that change type, intensity and duration of training.

  15. Patellar Tendinopathy

    PubMed Central

    Schwartz, Aaron; Watson, Jonathan N.; Hutchinson, Mark R.

    2015-01-01

    Context: Patellar tendinopathy is a common condition. There are a wide variety of treatment options available, the majority of which are nonoperative. No consensus exists on the optimal method of treatment. Evidence Acquisition: PubMed spanning 1962-2014. Study Design: Clinical review. Level of Evidence: Level 4. Results: The majority of cases resolve with nonoperative therapy: rest, physical therapy with eccentric exercises, cryotherapy, anti-inflammatories, corticosteroid injections, extracorporeal shockwave therapy, glyceryl trinitrate, platelet-rich plasma injections, and ultrasound-guided sclerosis. Refractory cases may require either open or arthroscopic debridement of the patellar tendon. Corticosteroid injections provide short-term pain relief but increase risk of tendon rupture. Anti-inflammatories and injectable agents have shown mixed results. Surgical treatment is effective in many refractory cases unresponsive to nonoperative modalities. Conclusion: Physical therapy with an eccentric exercise program is the mainstay of treatment for patellar tendinopathy. Platelet-rich plasma has demonstrated mixed results; evidence-based recommendations on its efficacy cannot be made. In the event that nonoperative treatment fails, surgical intervention has produced good to excellent outcomes in the majority of patients. PMID:26502416

  16. Reconstruction of a quadriceps tendon tear using Polyvinylidene fluoride sutures and patellar screw fixation: A biomechanical study.

    PubMed

    Sellei, R M; Bauer, E; Hofman, M; Kobbe, P; Lichte, P; Garrison, R L; Pape, H C; Horst, K

    2015-12-01

    Acute quadriceps tendon tears are infrequent injuries requiring surgical treatment. Improved stability after surgical repair may allow for earlier weight-bearing and range of motion. Therefore, a new implant was tested and compared with the "gold standard", using transosseous sutures. Quadriceps tendon tears were constructed using a cadaveric model of 12 fresh matched-pair specimens (aged 61-97; mean age: 82 years). The biomechanical testing compared non-absorbable suture anchors (Polyvinylidene fluoride) versus transosseous absorbable sutures (Polydioxanon). Following anatomic reconstruction, the repaired specimens were loaded until they failed (testing machine: Hounsfield H10KM, Redhill, United Kingdom; maximum force: 1000 N; load speed: 25 mm/min; maximum test length: 150 mm; pre-load: 5 N). Values for load until tear displacement, maximum load until complete failure of the construct (pullout or breakage of the sutures or anchors) and stiffness of the reconstruction were recorded. The stiffness found in the Polyvinylidene fluoride reconstruction (mean 9.83 N/mm) (standard deviation (SD) 7.75) showed a significant increase compared to the Polydioxanon reconstruction (mean 6.66 N/mm (SD 3.32); P=0.045). Transosseous fixation showed comparable results to the suture anchor system. There was no significant difference found in the maximum load to tear displacement (PVDF: 290.88 N (SD 106.01) vs. PDS: 266.75 N (SD 82.61); P=0.358). Using the Polyvinylidene fluoride thread showed comparable results to the established method in reconstruction of ruptured quadriceps tendon. Stiffness of the Polyvinylidene fluoride thread reconstruction was even greater than Polydioxanon thread. Improved stiffness may facilitate healing and is suggested as clinical relevance in reconstruction. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Medial Patellofemoral Ligament Reconstruction Using the Hamstring Tendon for Patellofemoral Joint Instability in an 81-Year-Old Female.

    PubMed

    Takahashi, Tsuneari; Takeshita, Katsushi

    2017-01-01

    Chronic patellofemoral instability occurs mainly in adolescent females and can also be induced by medial patellofemoral ligament (MPFL) injury. There are no case reports of MPFL reconstruction for chronic patellofemoral instability due to MPFL injury in aged populations. 81-year-old female presented with left knee pain, giving way, and patellar instability while climbing stairs, which continued for 18 months. Patellar apprehension test was positive, and roentgenogram showed lateral patellar subluxation. Conservative therapy was not successful; hence, we performed a lateral release and MPFL reconstruction surgery. After arthroscopic lateral release, the hamstring tendon was harvested, and a graft composite made of doubled hamstring tendon and polyester tape with a suspensory fixation device was prepared. Then, a femoral bone tunnel was constructed in a socket shape at the anatomical footprint of the MPFL. The graft was passed through the femoral tunnel, and free ends of the graft composite were sutured to the periosteum of the patella, using two suture anchors at 60° of knee flexion with patellar reduction. Physiotherapy was gradually started using a patella-stabilizing orthosis on the first postoperative day. Her Kujala score improved from 66 to 97 points, and Barthel index score improved from 70 to 100 points at 1 year after surgery. She neither developed patellofemoral joint OA nor had any recurrence of symptoms at the 5-year postoperative follow up. MPFL reconstruction using the hamstring tendon is an effective procedure for patients with chronic patellofemoral instability even after the age of 80 years.

  18. Spontaneous superior patellar dislocation in young age: case report and reduction technique

    PubMed Central

    Umar, Muhammad

    2017-01-01

    Abstract Superior patellar dislocation is a very rare pathology, which happens in middle age. We report a case of spontaneous superior patellar dislocation, which occurred at 30 years of age. Differential diagnosis is patellar tendon rupture, which could be reliably excluded by clinical examination and radiographs. Reduction manoeuvres should be tried with diluted intra-articular local anaesthetic for hydrodilatation to gain mechanical advantage. Splinting the knee in gentle flexion is recommended if general anaesthetic is employed. Recurrent dislocation or osteochondral fractures warrants surgical treatment. PMID:28458846

  19. Doppler ultrasonography of the anterior knee tendons in elite badminton players: colour fraction before and after match.

    PubMed

    Koenig, M J; Torp-Pedersen, S; Boesen, M I; Holm, C C; Bliddal, H

    2010-02-01

    Anterior knee tendon problems are seldom reported in badminton players although the game is obviously stressful to the lower extremities. Painful anterior knee tendons are common among elite badminton players. The anterior knee tendons exhibit colour Doppler activity. This activity increases after a match. Painful tendons have more Doppler activity than tendons without pain. Cohort study. 72 elite badminton players were interviewed about training, pain and injuries. The participants were scanned with high-end ultrasound equipment. Colour Doppler was used to examine the tendons of 64 players before a match and 46 players after a match. Intratendinous colour Doppler flow was measured as colour fraction (CF). The tendon complex was divided into three loci: the quadriceps tendon, the proximal patellar tendon and the insertion on the tibial tuberosity. Interview: Of the 72 players, 62 players had problems with 86 tendons in the lower extremity. Of these 86 tendons, 48 were the anterior knee tendons. Ultrasound: At baseline, the majority of players (87%) had colour Doppler flow in at least one scanning position. After a match, the percentage of the knee complexes involved did not change. CF increased significantly in the dominant leg at the tibial tuberosity; single players had a significantly higher CF after a match at the tibial tuberosity and in the patellar tendon both before and after a match. Painful tendons had the highest colour Doppler activity. Most elite badminton players had pain in the anterior knee tendons and intratendinous Doppler activity both before and after match. High levels of Doppler activity were associated with self-reported ongoing pain.

  20. Flexing and downsizing the femoral component is not detrimental to patellofemoral biomechanics in posterior-referencing cruciate-retaining total knee arthroplasty.

    PubMed

    Marra, Marco A; Strzelczak, Marta; Heesterbeek, Petra J C; van de Groes, Sebastiaan A W; Janssen, Dennis; Koopman, Bart F J M; Verdonschot, Nico; Wymenga, Ate B

    2018-03-20

    When downsizing the femoral component to prevent mediolateral overhang, notching of the anterior femoral cortex may occur, which could be solved by flexing the femoral component. In this study, we investigated the effect of flexion of the femoral component on patellar tendon moment arm, patellofemoral forces and kinematics in posterior-referencing CR-TKA. Our hypothesis was that flexion of the femoral component increases the patellar tendon moment arm, reduces the patellofemoral forces and provides stable kinematics. A validated musculoskeletal model of CR-TKA was used. The flexion of the femoral component was increased in four steps (0°, 3°, 6°, 9°) using posterior referencing, and different alignments were analysed in combination with three implant sizes (3, 4, 5). A chair-rising trial was analysed using the model, while simultaneously estimating quadriceps muscle force, patellofemoral contact force, tibiofemoral and patellofemoral kinematics. Compared to the reference case (size 4 and 0° flexion), for every 3° of increase in flexion of the femoral component the patellar tendon moment arm increased by 1% at knee extension. The peak quadriceps muscle force and patellofemoral contact force decreased by 2%, the patella shifted 0.8 mm more anteriorly and the remaining kinematics remained stable, with knee flexion. With the smaller size, the patellar tendon moment arm decreased by 6%, the quadriceps muscle force and patellofemoral contact force increased by 8 and 12%, and the patellar shifted 5 mm more posteriorly. Opposite trends were found with the bigger size. Flexing the femoral component with posterior referencing reduced the patellofemoral contact forces during a simulated chair-rising trial with a patient-specific musculoskeletal model of CR-TKA. There seems to be little risk when flexing and downsizing the femoral component, compared to when using a bigger size and neutral alignment. These findings provide relevant information to surgeons who wish to prevent anterior notching when downsizing the femoral component.

  1. Clinical and radiological outcomes after a quasi-anatomical reconstruction of medial patellofemoral ligament with gracilis tendon autograft.

    PubMed

    Monllau, Joan C; Masferrer-Pino, Àngel; Ginovart, Gerard; Pérez-Prieto, Daniel; Gelber, Pablo E; Sanchis-Alfonso, Vicente

    2017-08-01

    To analyse the clinical and radiological outcomes of a quasi-anatomical reconstruction of the medial patellofemoral ligament (MPFL) with a gracilis tendon autograft. Patients with objective recurrent patellar instability that were operated on from 2006 to 2012 were included. A quasi-anatomical surgical technique was performed using a gracilis tendon autograft. It was anatomically attached at the patella, and the adductor magnus tendon was also used as a pulley for femoral fixation (non-anatomical reconstruction). The IKDC, Kujala and Lysholm scores as well as Tegner and VAS for pain were collected preoperatively and at final follow-up. Radiographic measurements of patellar position tilt and signs of osteoarthritis (OA) as well as trochlear dysplasia were also recorded. Thirty-six patients were included. The mean age at surgery was 25.6 years. After a minimum 27 months of follow-up, all functional scores significantly improved (p < 0.001) with respect to the preoperative values. The VAS dropped from 6 (SD 2.48) to 2 (SD 1.58). No recurrence of dislocation was observed in this series. The apprehension sign was still apparent in one patient. The CT scan evaluation showed a significant decrease in patellar tilt (p < 0.001). On the Crosby and Insall grading scale, there were no changes in the radiological signs of OA. This specific MPFL reconstruction gives good clinical results and corrects patellar tilt. It did not affect the patellofemoral surfaces at the short term, as shown by the absence of radiological signs of OA in the CT scan. The procedure has been shown to be safe and suitable for the treatment of chronic patellar instability, including in adolescents with open physis. A new effective, inexpensive and easy-to-perform technique is described to reconstruct MPFL in the daily clinical practice. Therapeutic case series, Level IV.

  2. The effect of mechanical stimulation on the maturation of TDSCs-poly(L-lactide-co-e-caprolactone)/collagen scaffold constructs for tendon tissue engineering.

    PubMed

    Xu, Yuan; Dong, Shiwu; Zhou, Qiang; Mo, Xiumei; Song, Lei; Hou, Tianyong; Wu, Jinglei; Li, Songtao; Li, Yudong; Li, Pei; Gan, Yibo; Xu, Jianzhong

    2014-03-01

    Mechanical stimulation plays an important role in the development and remodeling of tendons. Tendon-derived stem cells (TDSCs) are an attractive cell source for tendon injury and tendon tissue engineering. However, these cells have not yet been fully explored for tendon tissue engineering application, and there is also lack of understanding to the effect of mechanical stimulation on the maturation of TDSCs-scaffold construct for tendon tissue engineering. In this study, we assessed the efficacy of TDSCs in a poly(L-lactide-co-ε-caprolactone)/collagen (P(LLA-CL)/Col) scaffold under mechanical stimulation for tendon tissue engineering both in vitro and in vivo, and evaluated the utility of the transplanted TDSCs-scaffold construct to promote rabbit patellar tendon defect regeneration. TDSCs displayed good proliferation and positive expressed tendon-related extracellular matrix (ECM) genes and proteins under mechanical stimulation in vitro. After implanting into the nude mice, the fluorescence imaging indicated that TDSCs had long-term survival, and the macroscopic evaluation, histology and immunohistochemistry examinations showed high-quality neo-tendon formation under mechanical stimulation in vivo. Furthermore, the histology, immunohistochemistry, collagen content assay and biomechanical testing data indicated that dynamically cultured TDSCs-scaffold construct could significantly contributed to tendon regeneration in a rabbit patellar tendon window defect model. TDSCs have significant potential to be used as seeded cells in the development of tissue-engineered tendons, which can be successfully fabricated through seeding of TDSCs in a P(LLA-CL)/Col scaffold followed by mechanical stimulation. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Whole-body vibration training induces hypertrophy of the human patellar tendon.

    PubMed

    Rieder, F; Wiesinger, H-P; Kösters, A; Müller, E; Seynnes, O R

    2016-08-01

    Animal studies suggest that regular exposure to whole-body vibration (WBV) induces an anabolic response in bone and tendon. However, the effects of this type of intervention on human tendon properties and its influence on the muscle-tendon unit function have never been investigated. The aim of this study was to investigate the effect of WBV training on the patellar tendon mechanical, material and morphological properties, the quadriceps muscle architecture and the knee extension torque-angle relationship. Fifty-five subjects were randomized into either a vibration, an active control, or an inactive control group. The active control subjects performed isometric squats on a vibration platform without vibration. Muscle and tendon properties were measured using ultrasonography and dynamometry. Vibration training induced an increase in proximal (6.3%) and mean (3.8%) tendon cross-sectional area, without any appreciable change in tendon stiffness and modulus or in muscle architectural parameters. Isometric torque at a knee angle of 90° increased in active controls (6.7%) only and the torque-angle relation remained globally unchanged in all groups. The present protocol did not appreciably alter knee extension torque production or the musculo-tendinous parameters underpinning this function. Nonetheless, this study shows for the first time that WBV elicits tendon hypertrophy in humans. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Predictors for anterior pelvic tilt following surgical correction of flexed knee gait including patellar tendon shortening in children with cerebral palsy.

    PubMed

    Böhm, Harald; Hösl, Matthias; Döderlein, Leonhard

    2017-05-01

    Patellar tendon shortening procedure within single event multilevel surgeries was shown to improve crouch gait in Cerebral Palsy (CP) patients. However, one of the drawbacks associated to the correction of flexed knee gait may be increased pelvic anterior tilt with compensatory lumbar lordosis. Which CP patients are at risk for excessive anterior pelvic tilt following correction of flexed knee gait including patellar tendon shortening? 32 patients with CP between 8 and 18 years GMFCS I&II were included. They received patellar tendon shortenings within multilevel surgery. Patients with concomitant knee flexor lengthening were excluded. Gait analysis and clinical testing was performed pre- and 24.1 (SD=1.9) months postoperatively. Patients were subdivided into more/less than 5° increase in anterior pelvic tilt. Preoperative measures indicating m. rectus and m. psoas shortness, knee flexor over-length, hip extensor and abdominal muscle weakness and equinus gait were compared between groups. Stepwise multilinear regression of the response value increase in pelvic tilt during stance phase was performed from parameters that were significantly different between groups. 34% of patients showed more than 5° increased pelvic anterior tilt postoperatively. Best predictors for anterior pelvic tilt from preoperative measures were increased m. rectus tone and reduced hip extension during walking that explained together 39% of the variance in increase of anterior pelvic tilt. Every third patient showed considerable increased pelvic tilt following surgery of flexed knee gait. In particular patients with preoperative higher muscle tone in m. rectus and lower hip extension during walking were at risk and both features need to be addressed in the therapy. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Ia Afferent input alters the recruitment thresholds and firing rates of single human motor units.

    PubMed

    Grande, G; Cafarelli, E

    2003-06-01

    Vibration of the patellar tendon recruits motor units in the knee extensors via excitation of muscle spindles and subsequent Ia afferent input to the alpha-motoneuron pool. Our first purpose was to determine if the recruitment threshold and firing rate of the same motor unit differed when recruited involuntarily via reflex or voluntarily via descending spinal pathways. Although Ia input is excitatory to the alpha-motoneuron pool, it has also been shown paradoxically to inhibit itself. Our second purpose was to determine if vibration of the patellar tendon during a voluntary knee extension causes a change in the firing rate of already recruited motor units. In the first protocol, 10 subjects voluntarily reproduced the same isometric force profile of the knee extensors that was elicited by vibration of the patellar tendon. Single motor unit recordings from the vastus lateralis (VL) were obtained with tungsten microelectrodes and unitary behaviour was examined during both reflex and voluntary knee extensions. Recordings from 135 single motor units showed that both recruitment thresholds and firing rates were lower during reflex contractions. In the second protocol, 7 subjects maintained a voluntary knee extension at 30 N for approximately 40-45 s. Three bursts of patellar tendon vibration were superimposed at regular intervals throughout the contraction and changes in the firing rate of already recruited motor units were examined. A total of 35 motor units were recorded and each burst of superimposed vibration caused a momentary reduction in the firing rates and recruitment of additional units. Our data provide evidence that Ia input modulates the recruitment thresholds and firing rates of motor units providing more flexibility within the neuromuscular system to grade force at low levels of force production.

  6. Mechanoactive Scaffold Induces Tendon Remodeling and Expression of Fibrocartilage Markers

    PubMed Central

    Spalazzi, Jeffrey P.; Vyner, Moira C.; Jacobs, Matthew T.; Moffat, Kristen L.

    2008-01-01

    Biological fixation of soft tissue-based grafts for anterior cruciate ligament (ACL) reconstruction poses a major clinical challenge. The ACL integrates with subchondral bone through a fibrocartilage enthesis, which serves to minimize stress concentrations and enables load transfer between two distinct tissue types. Functional integration thus requires the reestablishment of this fibrocartilage interface on reconstructed ACL grafts. We designed and characterized a novel mechanoactive scaffold based on a composite of poly-α-hydroxyester nanofibers and sintered microspheres; we then used the scaffold to test the hypothesis that scaffold-induced compression of tendon grafts would result in matrix remodeling and the expression of fibrocartilage interface-related markers. Histology coupled with confocal microscopy and biochemical assays were used to evaluate the effects of scaffold-induced compression on tendon matrix collagen distribution, cellularity, proteoglycan content, and gene expression over a 2-week period. Scaffold contraction resulted in over 15% compression of the patellar tendon graft and upregulated the expression of fibrocartilage-related markers such as Type II collagen, aggrecan, and transforming growth factor-β3 (TGF-β3). Additionally, proteoglycan content was higher in the compressed tendon group after 1 day. The data suggest the potential of a mechanoactive scaffold to promote the formation of an anatomic fibrocartilage enthesis on tendon-based ACL reconstruction grafts. PMID:18512112

  7. Mechanoactive scaffold induces tendon remodeling and expression of fibrocartilage markers.

    PubMed

    Spalazzi, Jeffrey P; Vyner, Moira C; Jacobs, Matthew T; Moffat, Kristen L; Lu, Helen H

    2008-08-01

    Biological fixation of soft tissue-based grafts for anterior cruciate ligament (ACL) reconstruction poses a major clinical challenge. The ACL integrates with subchondral bone through a fibrocartilage enthesis, which serves to minimize stress concentrations and enables load transfer between two distinct tissue types. Functional integration thus requires the reestablishment of this fibrocartilage interface on reconstructed ACL grafts. We designed and characterized a novel mechanoactive scaffold based on a composite of poly-alpha-hydroxyester nanofibers and sintered microspheres; we then used the scaffold to test the hypothesis that scaffold-induced compression of tendon grafts would result in matrix remodeling and the expression of fibrocartilage interface-related markers. Histology coupled with confocal microscopy and biochemical assays were used to evaluate the effects of scaffold-induced compression on tendon matrix collagen distribution, cellularity, proteoglycan content, and gene expression over a 2-week period. Scaffold contraction resulted in over 15% compression of the patellar tendon graft and upregulated the expression of fibrocartilage-related markers such as Type II collagen, aggrecan, and transforming growth factor-beta3 (TGF-beta3). Additionally, proteoglycan content was higher in the compressed tendon group after 1 day. The data suggest the potential of a mechanoactive scaffold to promote the formation of an anatomic fibrocartilage enthesis on tendon-based ACL reconstruction grafts.

  8. A mini-invasive adductor magnus tendon transfer technique for medial patellofemoral ligament reconstruction: a technical note.

    PubMed

    Sillanpää, Petri J; Mäenpää, Heikki M; Mattila, Ville M; Visuri, Tuomo; Pihlajamäki, Harri

    2009-05-01

    Patellar dislocations are associated with injuries to the medial patellofemoral ligament (MPFL). Several techniques for MPFL reconstruction have been recently published with some disadvantages involved, including large skin incisions and donor site morbidity. Arthroscopic stabilizing techniques carry the potential of inadequate restoration of MPFL function. We present a minimally invasive technique for MPFL reconstruction using adductor magnus tendon autograft. This technique is easily performed, safe, and provides a stabilizing effect equal to current MPFL reconstructions. Skin incision of only 3-4 cm is located at the level of the proximal half of the patella. After identifying the distal insertion of the adductor magnus tendon, a tendon harvester is introduced to harvest the medial two-thirds of the tendon, while the distal insertion is left intact. The adductor magnus tendon is cut at 12-14 cm from its distal insertion and transferred into the patellar medial margin. Two suture anchors are inserted through the same incision at the superomedial aspect of the patella in the anatomic MPFL origin. The graft is tightened at 30 degrees knee flexion. Aftercare includes 4 weeks of brace treatment with restricted range of motion.

  9. [Arthroscopic reconstruction of anterior cruciate ligament with press-fit technique].

    PubMed

    Halder, A M

    2010-08-01

    Problems related to the use of interference screws for fixation of bone-patellar tendon-bone grafts for anterior cruciate ligament (ACL) replacement have led to increasing interest in press-fit techniques. Most of the described techniques use press-fit fixation on either the femoral or tibial side. Therefore an arthroscopic technique was developed which achieves bone-patellar tendon-bone graft fixation by press-fit on both sides without the need for supplemental fixation material. The first consecutive 40 patients were examined clinically with a KT-1000 arthrometer and radiologically after a mean of 28.7 months (range 20-40 months) postoperatively. The mean difference in side-to-side laxity was 1.3 mm (SD 2.2 mm) and the results according to the International Knee Documentation Committee (IKDC) score were as follows: 7 A, 28 B, 5 C, 0 D. The presented press-fit technique avoids all complications related to the use of interference screws. It achieves primary stable fixation of the bone-patellar tendon-bone graft thereby allowing early functional rehabilitation. However, fixation strength depends on bone quality and the arthroscopic procedure is demanding. The results showed reliable stabilization of the operated knees.

  10. Anatomically remote muscle contraction facilitates patellar tendon reflex reinforcement while mental activity does not: a within-participants experimental trial.

    PubMed

    Passmore, Steven R; Bruno, Paul A

    2012-09-07

    The Jendrassik maneuver (JM) is a remote facilitation muscular contraction shown to affect amplitude and temporal components of the human stretch reflex. Conflicting theoretical models exist regarding the neurological mechanism related to its ability to reinforce reflex parameters. One mechanism involves the gamma motoneurons of the fusimotor system, which are subject to both physical and mental activity. A second mechanism describes reduced alpha motoneuron presynaptic inhibition, which is not subject to mental activity. In the current study, we determined if mental activity could be used to create a reflex facilitation comparable to a remote muscle contraction. Using a within-participants design, we investigated the relative effect of the JM and a successfully employed mental task (Stroop task) on the amplitude and temporal components of the patellar tendon reflex. We found that the addition of mental activity had no influence on the patellar tendon reflex parameters measured, while the JM provided facilitation (increased reflex amplitude, decreased total reflex time). The findings from this study support the view that the mechanism for the JM is a reduction in presynaptic inhibition of alpha motoneurons as it is influenced by physical and not mental activity.

  11. Arthroscopic anterior cruciate ligament reconstruction using the double press- fit technique: an alternative to interference screw fixation.

    PubMed

    Halder, Andreas M; Ludwig, Silke; Neumann, Wolfram

    2002-01-01

    Patellar tendon autograft fixation in arthroscopic anterior cruciate ligament reconstruction is commonly accomplished using interference screws. However, improper insertion of the screws may reduce primary stability, injure the posterior femoral cortex, or displace hardware into the joint. Even if placed properly, metallic screws interfere with postoperative magnetic resonance imaging. In case of revision surgery, removing screws may be difficult and leaves bone defects. Retrospective study. An arthroscopic technique was developed that achieves patellar tendon autograft fixation by press-fit without any supplemental internal fixation. Forty patients were examined clinically and by KT-1000 arthrometer 28.7 months (range, 22 to 40 months) postoperatively. The mean difference in side-to-side laxity was 1.3 mm (SD 2.2) and the results according to the IKDC score were as follows: 7 A, 28 B, 5 C, and 0 D. The double press-fit technique we present avoids all complications related to the use of interference screws and creates an ideal environment for osseous integration of the bone-patellar tendon-bone autograft. Concurrently, it achieves a stable fixation of the autograft and allows early functional rehabilitation. However, fixation strength depends on bone quality and the arthroscopic procedure is demanding.

  12. Healing of donor site in bone-tendon-bone ACL reconstruction accelerated with plasma rich in growth factors: a randomized clinical trial.

    PubMed

    Seijas, Roberto; Rius, Marta; Ares, Oscar; García-Balletbó, Montserrat; Serra, Iván; Cugat, Ramón

    2015-04-01

    To determine whether the use of plasma rich in growth factors accelerates healing of the donor site in bone-tendon-bone anterior cruciate ligament (ACL) reconstruction (patellar graft). The use of the patellar graft presents post-operative problems such as anterior knee pain, which limits its use and leads to preference being taken for alternative grafts. A double-blind, randomized, clinical trial was performed comparing two groups of patients who underwent ACL reconstruction using patellar tendon graft and comparing the use of plasma rich in growth factors at the donor site after graft harvest in terms of local regeneration by ultrasound assessment. The plasma rich in growth factors group shows earlier donor site regeneration in comparison with the control group (2 months earlier), with significant differences in the first 4 months of the follow-up. The application of plasma rich in growth factors shows accelerated tissue regeneration processes with respect to the control group. This fact, together with the previously published with similar conclusions, can create a knowledge basis in order to set out new recovery guidelines following ACL reconstruction. Therapeutic study, Level I.

  13. Autologous platelet-rich plasma gel to reduce donor-site morbidity after patellar tendon graft harvesting for anterior cruciate ligament reconstruction: a randomized, controlled clinical study.

    PubMed

    Cervellin, M; de Girolamo, L; Bait, C; Denti, M; Volpi, P

    2012-01-01

    Bone-patellar tendon-bone technique (BPTB) for anterior cruciate ligament injuries is associated with a higher risk of donor-site morbidity. To evaluate whether platelet-rich plasma (PRP), due to its anti-inflammatory properties and capacity to stimulate tissue regeneration, was able to reduce the anterior knee pain, the kneeling pain, and donor-site morbidity, as evidenced by evaluation of VISA and VAS scoring scales and MRI analysis of the tendon and bone defect, we performed a clinical randomized controlled study where PRP gel was applied to donor site after ACL reconstruction with BPTB. Forty young athletes with the indication of ACL reconstruction with patellar tendon grafts were randomly assigned to group A (n = 20 patients, control group) or group B (n = 20 patients, PRP group). The autologous PRP gel was applied to both the patellar and tendon bone plug harvest site and stabilized by the peritenon suture. At 12-month follow-up, all patients underwent clinical examination and VAS and VISA questionnaires, respectively, evaluating the average daily pain of the knee and the pain during particular activities involving the knee, were filled. MRI at the same time point was also performed. VISA scores were significantly higher in the patients treated with PRP (84.5 ± 11.8 and 97.8 ± 2.5 for group A and for group B; P = 0.041), whereas no significant difference in postoperative VAS scores between the two groups was observed (1 ± 1.4 and 0.6 ± 0.9 for group A and group B, n.s.). In 85% of PRP group patients, the tibial and patellar bone defect was satisfactorily filled by new bony tissue (>70% of bone gap filled), whereas this percentage was just of 60% in control group patients, but this difference was not statistically significant. The study shows the usefulness of PRP in reducing subjective pain at the donor-site level after ACL reconstruction with BPTB. However, this approach deserves further investigations to confirm PRP efficacy and to elucidate its mechanism of action. Prospective randomized controlled study, Level I.

  14. Proteomic Differences between Male and Female Anterior Cruciate Ligament and Patellar Tendon

    PubMed Central

    Little, Dianne; Thompson, J. Will; Dubois, Laura G.; Ruch, David S.; Moseley, M. Arthur; Guilak, Farshid

    2014-01-01

    The risk of anterior cruciate ligament (ACL) injury and re-injury is greater for women than men. Among other factors, compositional differences may play a role in this differential risk. Patellar tendon (PT) autografts are commonly used during reconstruction. The aim of the study was to compare protein expression in male and female ACL and PT. We hypothesized that there would be differences in key structural components between PT and ACL, and that components of the proteome critical for response to mechanical loading and response to injury would demonstrate significant differences between male and female. Two-dimensional liquid chromatography-tandem mass spectrometry and a label-free quantitative approach was used to identify proteomic differences between male and female PT and ACL. ACL contained less type I and more type III collagen than PT. There were tissue-specific differences in expression of proteoglycans, and ACL was enriched in elastin, tenascin C and X, cartilage oligomeric matrix protein, thrombospondin 4 and periostin. Between male and female donors, alcohol dehydrogenase 1B and complement component 9 were enriched in female compared to male. Myocilin was the major protein enriched in males compared to females. Important compositional differences between PT and ACL were identified, and we identified differences in pathways related to extracellular matrix regulation, complement, apoptosis, metabolism of advanced glycation end-products and response to mechanical loading between males and females. Identification of proteomic differences between male and female PT and ACL has identified novel pathways which may lead to improved understanding of differential ACL injury and re-injury risk between males and females. PMID:24818782

  15. Decorin expression is important for age-related changes in tendon structure and mechanical properties

    PubMed Central

    Dunkman, Andrew A.; Buckley, Mark R.; Mienaltowski, Michael J.; Adams, Sheila M.; Thomas, Stephen J.; Satchell, Lauren; Kumar, Akash; Pathmanathan, Lydia; Beason, David P.; Iozzo, Renato V.; Birk, David E.; Soslowsky, Louis J.

    2013-01-01

    The aging population is at an increased risk of tendon injury and tendinopathy. Elucidating the molecular basis of tendon aging is crucial to understanding the age-related changes in structure and function in this vulnerable tissue. In this study, the structural and functional features of tendon aging are investigated. In addition, the roles of decorin and biglycan in the aging process were analyzed using transgenic mice at both mature and aged time points. Our hypothesis is that the increase in tendon injuries in the aging population is the result of altered structural properties that reduce the biomechanical function of the tendon and consequently increase susceptibility to injury. Decorin and biglycan are important regulators of tendon structure and therefore, we further hypothesized that decreased function in aged tendons is partly the result of altered decorin and biglycan expression. Biomechanical analyses of mature (day 150) and aged (day 570) patellar tendons revealed deteriorating viscoelastic properties with age. Histology and polarized light microscopy demonstrated decreased cellularity, alterations in tenocyte shape, and reduced collagen fiber alignment in the aged tendons. Ultrastructural analysis of fibril diameter distributions indicated an altered distribution in aged tendons with an increase of large diameter fibrils. Aged wild type tendons maintained expression of decorin which was associated with the structural and functional changes seen in aged tendons. Aged patellar tendons exhibited altered and generally inferior properties across multiple assays. However, decorin-null tendons exhibited significantly decreased effects of aging compared to the other genotypes. The amelioration of the functional deficits seen in the absence of decorin in aged tendons was associated with altered tendon fibril structure. Fibril diameter distributions in the decorin-null aged tendons were comparable to those observed in the mature wild type tendon with the absence of the subpopulation containing large diameter fibrils. Collectively, our findings provide evidence for age-dependent alterations in tendon architecture and functional activity, and further show that lack of stromal decorin attenuates these changes. PMID:23178232

  16. Astym® Therapy for the Management of Recalcitrant Knee Joint Stiffness after Total Knee Arthroplasty.

    PubMed

    Bhave, Anil; Corcoran, James; Cherian, Jeffery J; Mont, Michael A

    2016-01-01

    Knee stiffness is a common complication after total knee arthroplasty (TKA). Despite studies published on the surgical management of reduced range of motion (ROM) after TKA, there is limited evidence on the nonoperative management of joint and soft tissue imbalances possibly contributing to reduced knee ROM. This report assesses changes in ROM, pain, function, and patellar tendon length after Astym® joint mobilization use. A 38-year-old male professional skier had a right TKA 3 months before presentation with 2 subsequent manipulations under anesthesia secondary to persistent knee stiffness. He had patellar baja on radiograph, a reduced arc of ROM, reduced patellar mobility and muscular extensibility, and pain to palpation along the patellar tendon. He had 12 visits of physical therapy with the use of Astym®, patellar mobilization, and tibio-femoral mobilizations with movement. The patient also used a customized knee device at home for prolonged knee extension stretching. The patient was treated for 12 visits, along with home use of customized bracing for knee extension. Significant improvements were seen in pain, function, and ROM. He returned to work full-time, ambulated prolonged distances, and negotiated stairs pain-free. He also demonstrated resolution of patellar baja radiographically. Conservative management of recalcitrant knee joint stiffness after primary TKA can be effective in restoring knee mobility and reducing pain and activity limitation. A multimodal approach using Astym® treatment, customized knee bracing, and targeted joint mobilization can be effective in resolving knee joint stiffness.

  17. Comparing the effects of eccentric training with eccentric training and static stretching exercises in the treatment of patellar tendinopathy. A controlled clinical trial.

    PubMed

    Dimitrios, Stasinopoulos; Pantelis, Manias; Kalliopi, Stasinopoulou

    2012-05-01

    The aim of the present study was to investigate the effectiveness of eccentric training and eccentric training with static stretching exercises in the management of patellar tendinopathy. Controlled clinical trial. Rheumatology and rehabilitation centre. Forty-three patients who had patellar tendinopathy for at least three months. They were allocated to two groups by alternative allocation. Group A (n = 22) was treated with eccentric training of patellar tendon and static stretching exercises of quadriceps and hamstrings and Group B (n = 21) received eccentric training of patellar tendon. All patients received five treatments per week for four weeks. Pain and function were evaluated using the VISA-P score at baseline, at the end of treatment (week 4), and six months (week 24) after the end of treatment. At the end of treatment, there was a rise in VISA-P score in both groups compared with baseline (P<0.0005, paired t test). There were significant differences in the VISA-P score between the groups at the end of treatment (+14; 10 to 18) and at the six-month follow-up (+19; 13 to 24); eccentric training and static stretching exercises produced the largest effect (P<0.0005, one-way ANOVA). Eccentric training and static stretching exercises is superior to eccentric training alone to reduce pain and improve function in patients with patellar tendinopathy at the end of the treatment and at follow-up.

  18. Sagittal plane tilting deformity of the patellofemoral joint: a new concept in patients with chondromalacia patella.

    PubMed

    Aksahin, Ertugrul; Aktekin, Cem Nuri; Kocadal, Onur; Duran, Semra; Gunay, Cüneyd; Kaya, Defne; Hapa, Onur; Pepe, Murad

    2017-10-01

    The aims of this study were to evaluate sagittal plane alignment in patients with chondromalacia patella via magnetic resonance imaging (MRI), analyse the relationships between the location of the patellar cartilaginous lesions and sagittal alignment and finally investigate the relationships between the sagittal plane malalignment and patellofemoral loadings using by finite element analysis. Fifty-one patients who were diagnosed with isolated modified Outerbridge grade 3-4 patellar chondromalacia based on MRI evaluation and 51 control subjects were evaluated. Chondromalacia patella patients were divided into three subgroups according to the chondral lesion location as superior, middle and inferior. The patella-patellar tendon angle (P-PT) was used for evaluation of sagittal alignment of patellofemoral joint. Each subgroup was compared with control group by using P-PT angle. To investigate the biomechanical effects of sagittal plane malpositioning on patellofemoral joint, bone models were created at 30°, 60° and 90° knee flexion by using mean P-PT angles, which obtained from patients with chondromalacia patellae and control subjects. The total loading and contact area values of the patellofemoral joints were investigated by finite element analysis. The mean age of all participants was 52.9 ± 8.2 years. The mean P-PT angle was significantly lower in chondromalacia group (142.1° ± 3.6°) compared to control group (144.5° ± 5.3°) (p = 0.008). Chondral lesions were located in superior, middle and inferior zones in 16, 20 and 15 patients, respectively. The mean P-PT angles in patients with superior (141.8 ± 2.7) and inferior subgroups (139.2 ± 2.3) were significantly lower than the values in the control group (p < 0.05). The contact area values were detected higher in models with chondromalacia than in the control models at the same flexion degrees. There were increased loadings at 30° and 90° flexions in the sagittal patellar tilt models. This study revealed that sagittal plain malpositioning of the patellofemoral joint might be related to chondromalacia, especially in the presence of lesions in the upper and lower part of the patella. This condition leads to supraphysiological loadings on the patellofemoral joint. Sagittal patellar tilt should be considered in the evaluation and management of patellar cartilage defects. Taking sagittal plane malalignment into consideration in patellofemoral joint evaluation will enable us to design new physical and surgical modalities. IV.

  19. Extensor Mechanism Disruption after Total Knee Arthroplasty: A Case Series and Review of Literature.

    PubMed

    Vaishya, Raju; Agarwal, Amit Kumar; Vijay, Vipul

    2016-02-04

    Extensor mechanism disruption following total knee arthroplasty (TKA) is a rare but devastating complication. These patients may require revision of the implants, but even then, it may not be possible to restore the normal function of the knee after the disruption. The patterns of extensor mechanism disruption can broadly be classified into three types: suprapatellar (quadriceps tendon rupture), transpatellar (patellar fracture), or infrapatellar (patellar tendon rupture). Infrapatellar tendon ruptures are the worst injuries, as they carry maximum morbidity and are challenging to manage. The disruption of the extensor mechanism may occur either intra-operatively or in the immediate postoperative period due to an injury. The treatment of extensor mechanism complications after TKA may include either nonsurgical management or surgical intervention in the form of primary repair or reconstruction with autogenous, allogeneic, or synthetic substitutes. We have provided an algorithm for the management of extensor mechanism disruption after TKA.

  20. Persistence of deep-tendon reflexes during partial cataplexy.

    PubMed

    Barateau, Lucie; Pizza, Fabio; Lopez, Régis; Antelmi, Elena; Plazzi, Giuseppe; Dauvilliers, Yves

    2018-05-01

    Deep-tendon reflexes are abolished during generalized cataplexy, but whether this is the case in partial cataplexy currently remains unknown. Partial cataplexy may mimic other neurologic/psychiatric phenomena, and knowledge of the reflexes status may provide information for differential diagnosis. We assessed whether deep-tendon reflexes are persistent during partial cataplexy. Five drug-free patients with typical diagnoses of narcolepsy and clear-cut partial cataplexy were diagnosed in Reference Narcolepsy Centers in France and Italy. Biceps and patellar reflexes were elicited by physicians in charge and video-documented during cataplexy. Reflexes were assessed several times for each patient in different conditions and for various localizations of cataplexy. The absence of tendon reflexes and complete loss of muscle tone during generalized cataplexy was confirmed, but the persistence of those reflexes during several partial cataplectic attacks at different ages, gender, localization of cataplexy (upper limbs, face) and reflexes (biceps, patellar) in drug-naive or withdrawal conditions was documented. The persistence of tendon reflexes during several partial cataplexy episodes contrasts with their absence during generalized cataplexy. This discovery has clinical implications: the persistence of tendon reflexes does not rule out cataplexy diagnosis for partial attacks, whereas their transient abolishment or persistence during generalized attacks indicates cataplexy or pseudocataplexy, respectively. Copyright © 2018. Published by Elsevier B.V.

  1. Revision of anterior cruciate ligament reconstruction with allografts in patients younger than 40 years old: a 2 to 4 year results.

    PubMed

    Pascual-Garrido, Cecilia; Carbo, L; Makino, A

    2014-05-01

    The purpose of this study is first to report the outcomes, at 4 years follow-up, in revision ACL surgery using allografts in patients younger than 40 years old, and then compared soft tissue allografts to bone tendon allografts. This retrospective study included 47 patients who underwent ACL revision surgery with fresh-frozen allografts. Patellar tendon allograft or tibialis anterior allograft was used. Twenty-seven patients undergoing ACL revision with patellar tendon allograft were compared retrospectively with twenty-two patients undergoing the same procedure with soft tissue tibialis anterior allograft. Lysholm, IKDC, and KT-1000 values were obtained preoperatively and postoperatively. The average patient follow-up was 4.6 years (±2.5). The mean age at time of the revision was 34 years old (±6.3). Overall, patients reported the overall condition of their knee as excellent or good in 85% of the patients (10 excellent, 33 good). Based on their experience, 85% would have the surgery again if they had the same problem in the other knee. Both subgroups experienced significant improvement in Lysholm, IKDC, and KT-1000 values, with no difference found between groups at final follow-up. Revision ACL with allografts has excellent and good results in 85% of patients younger than 40 years old. No statistical difference was seen between soft tissue (tibialis anterior) and patellar tendon allograft. IV.

  2. Patellar tendon rupture repair using Dall-Miles cable.

    PubMed

    Shelbourne, K D; Darmelio, M P; Klootwyk, T E

    2001-01-01

    Ten patients underwent patellar tendon repair with end-to-end suture technique and medial and lateral retinacular repair, as well as reinforcement with a Dall-Miles cable through the patella and tibial tubercle. The cable was tensioned at 60 degrees of flexion to allow immediate range of motion to at least 100 degrees of flexion and to protect the repair from undue tension while healing. Accurate tendon length was obtained from a lateral radiograph of the noninvolved knee in 60 degrees of flexion. Patients were allowed to bear full weight as tolerated postoperatively. A knee immobilizer was worn for approximately 2 weeks when adequate muscular control of the leg was attained. The cable was removed 6-8 weeks postoperatively, at which time range of motion equal to the opposite extremity was sought. Full extension was obtained by 1 week postoperatively. Average postoperative knee flexion was 88 degrees at 2 weeks, 112 degrees at 1 month, 133 at 3 months, and 138 degrees at 6 months compared to flexion of 141 degrees in the noninvolved knee. Mean quadriceps muscle strength 1 year postoperatively was 72%+/-11% of the noninvolved leg. No patient had patella infera or rerupture after surgery. Repair of a patellar tendon rupture with end-to-end techniques reinforced with a Dall-Miles cable allows immediate rehabilitation without the need for prolonged immobilization. This technique allows restoration of full range of motion early postoperatively and enables patients to regain adequate quadriceps strength.

  3. Hip proprioceptors preferentially modulate reflexes of the leg in human spinal cord injury

    PubMed Central

    Onushko, Tanya; Hyngstrom, Allison

    2013-01-01

    Stretch-sensitive afferent feedback from hip muscles has been shown to trigger long-lasting, multijoint reflex responses in people with chronic spinal cord injury (SCI). These reflexes could have important implications for control of leg movements during functional activities, such as walking. Because the control of leg movement relies on reflex regulation at all joints of the limb, we sought to determine whether stretch of hip muscles modulates reflex activity at the knee and ankle and, conversely, whether knee and ankle stretch afferents affect hip-triggered reflexes. A custom-built servomotor apparatus was used to stretch the hip muscles in nine chronic SCI subjects by oscillating the legs about the hip joint bilaterally from 10° of extension to 40° flexion. To test whether stretch-related feedback from the knee or ankle would be affected by hip movement, patellar tendon percussions and Achilles tendon vibration were delivered when the hip was either extending or flexing. Surface electromyograms (EMGs) and joint torques were recorded from both legs. Patellar tendon percussions and Achilles tendon vibration both elicited reflex responses local to the knee or ankle, respectively, and did not influence reflex responses observed at the hip. Rather, the movement direction of the hip modulated the reflex responses local to the joint. The patellar tendon reflex amplitude was larger when the perturbation was delivered during hip extension compared with hip flexion. The response to Achilles vibration was modulated by hip movement, with an increased tonic component during hip flexion compared with extension. These results demonstrate that hip-mediated sensory signals modulate activity in distal muscles of the leg and appear to play a unique role in modulation of spastic muscle activity throughout the leg in SCI. PMID:23615544

  4. The Anatomic Midpoint of the Attachment of the Medial Patellofemoral Complex.

    PubMed

    Tanaka, Miho J; Voss, Andreas; Fulkerson, John P

    2016-07-20

    The medial patellofemoral ligament varies in attachment of its fibers to the patella and vastus intermedius tendon. Our aim was to identify and describe its anatomic midpoint. To account for the variability of the attachment site, we refer to it as the medial patellofemoral complex. Using AutoCAD software, we identified the midpoint of the medial patellofemoral complex attachment on photographs of 31 cadaveric knee dissections. The midpoint was referenced relative to the superior articular surface of the patella (P1) and was described in terms of the percentage of the patellar articular length distal to this point. A second point, at the junction of the medial border of the vastus intermedius tendon with the superior articular border of the patella, was identified (P2). The distances of the midpoint to P1 and P2 were calculated and were compared using paired t tests. Twenty-five images had appropriate quality and landmarks for digital analysis. The midpoint of the medial patellofemoral complex was located a mean (and standard deviation) of 2.3% ± 15.8% of the patellar articular length distal to the superior pole and was at or proximal to P1 in 12 knees. In all knees, the midpoint was at or proximal to P2. After exclusion of 2 knees with vastus intermedius tendon attachments only, the medial patellofemoral complex midpoint was closer to P2 (5.3% ± 8.6% of the patellar articular length) than to P1 (9.3% ± 8.5% of the patellar articular length) (p = 0.06). The midpoint of the medial patellofemoral complex was 2.3% of the articular length distal to the superior pole of the patella. Additionally, we describe an anatomic landmark at the junction of the medial border of the vastus intermedius tendon and the articular border of the patella that approximates the midpoint of this complex. Our study shows that the anatomic midpoint of the attachment of the medial patellofemoral complex is proximal to the junction of the medial vastus intermedius tendon and the articular border of the patella, suggesting that graft placement may be more anatomic on the vastus intermedius tendon rather than on the patella. Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.

  5. Articulated Bone Block for Posterior Cruciate Ligament Reconstruction Using Bone-Patellar Tendon-Bone Autograft: Surgical Technique to Facilitate Graft Passage.

    PubMed

    Cugat, Ramón; Alentorn-Geli, Eduard; Cuscó, Xavier; Navarro, Jordi; Steinbacher, Gilbert; Álvarez-Díaz, Pedro; Seijas, Roberto; Barastegui, David; García-Balletbó, Montse

    2018-02-01

    Posterior cruciate ligament reconstruction using the transtibial technique provides successful clinical outcomes. However, a bone-patellar tendon-bone (BTB) autograft with the transtibial technique has not been used by some surgeons because of concerns with graft passage from the tibial to the femoral tunnels (sharp turn) that can damage graft fibers. In the present surgical technique, an arthroscopic, transtibial, single-bundle technique for posterior cruciate ligament reconstruction using the BTB autograft with an easy and effective technical tip to facilitate graft passage is presented. Once the BTB is harvested, the femoral bone block is divided into 2 equal-sized blocks providing an articulated structure while preserving the tendon component. This facilitates the passage of the BTB tendon once it is entered in the posterior tibia and the graft has to make a sharp turn to reach the femoral tunnel. This easy and effective technique tip may avoid graft damage during the sharp turn, while maintaining all the advantages of a BTB autograft (bone-to-bone healing, own tissue with fast incorporation, and strong fixation and stability).

  6. Effect of alignment perturbations in a trans-tibial prosthesis user: A pilot study.

    PubMed

    Courtney, Anna; Orendurff, Michael S; Buis, Arjan

    2016-04-01

    A recurring complication in trans-tibial prosthetic limb users is "poor socket fit" with painful residuum-socket interfaces, a consequence of excess pressure. This is due to both poor socket fit and poor socket alignment; however, the interaction of these factors has not been quantified. Through evaluation of kinetic data this study aimed to articulate an interaction uniting socket design, alignment and interface pressures. The results will help to refine future studies and will hopefully help determine whether sockets can be designed, fitted and aligned to maximize mobility whilst minimizing injurious forces. Interface pressures were recorded throughout ambulation in one user with "optimal (reference) alignment" followed by 5 malalignments in a patellar tendon-bearing and a hydrocast socket. Marked differences in pressure distribution were discovered when equating the patellar tendon-bearing against the hydrocast socket and when comparing interface pressures from reference with offset alignment. Patellar tendon-bearing sockets were found to be more sensitive to alignment perturbations than hydrocast sockets. A complex interaction was found, with the most prominent finding demonstrating the requisite for attainment of optimal alignment: a translational alignment error of 10 mm can increase maximum peak pressures by 227% (mean 17.5%). Refinements for future trials are described and the necessity for future research into socket design, alignment and interface pressures has been estabilished.

  7. Autonomic responses to ultrasound-guided percutaneous needle electrolysis of the patellar tendon in healthy male footballers.

    PubMed

    de la Cruz Torres, Blanca; Albornoz Cabello, Manuel; García Bermejo, Paula; Naranjo Orellana, José

    2016-08-01

    Ultrasound (US)-guided percutaneous needle electrolysis (PNE) is a novel minimally invasive approach, which involves the application of a galvanic current via an acupuncture needle. As in any procedure involving needling, vagal reactions have been reported during PNE. To examine for changes in autonomic activity during the US-guided PNE technique on healthy patellar tendons by measurement and analysis of heart rate variability (HRV). Twenty-two male footballers were randomly allocated to: a control group (11 players), for whom HRV was recorded for 10 min, both at rest and during an exhaustive US examination of the patellar tendon and adjacent structures; and an experimental group (11 players), for whom HRV was recorded for 10 min, both at rest and during application of US-guided PNE on the patellar tendon. The following HRV parameters were assessed: mean NN interval, mean heart rate, time domain parameters (SDNN, rMSSD, pNN50), diameters of the Poincaré plot (SD1, SD2), stress score, and sympathetic/parasympathetic ratio. There were no differences between groups in any baseline measurements, nor were there any significant differences between control group measurements (baseline vs intervention). The experimental group exhibited statistically significant increases in SDNN/SD1 (p=0.02/p=0.03) and SD2 (p=0.03), indicating increased parasympathetic and decreased sympathetic activity, respectively. US-guided PNE was associated with an autonomic imbalance characterised by greater parasympathetic activity, which could potentially result in a vasovagal reaction. Care should be taken to monitor for adverse reactions during US-guided PNE and simple HRV indicators may have a role in early detection. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  8. The use of motion analysis to measure pain-related behaviour in a rat model of degenerative tendon injuries.

    PubMed

    Fu, Sai-Chuen; Chan, Kai-Ming; Chan, Lai-Shan; Fong, Daniel Tik-Pui; Lui, Po-Yee Pauline

    2009-05-15

    Chronic tendinopathy is characterized with longstanding activity-related pain with degenerative tendon injuries. An objective tool to measure painful responses in animal models is essential for the development of effective treatment for tendinopathy. Gait analysis has been developed to monitor the inflammatory pain in small animals. We reported the use of motion analysis to monitor gait changes in a rat model of degenerative tendon injury. Intratendinous injection of collagenase into the left patellar tendon of Sprague Dawley rat was used to induce degenerative tendon injury, while an equal volume of saline was injected in the control groups. Motion analyses with a high speed video camera were performed on all rats at pre-injury, 2, 4, 8, 12 or 16 weeks post injection. In the end-point study, the rats were sacrificed to obtain tendon samples for histological examination after motion analyses. In the follow-up study, repeated motion analyses were performed on another group of collagenase-treated and saline-treated rats. The results showed that rats with injured patellar tendon exhibited altered walking gait as compared to the controls. The change in double stance duration in the collagenase-treated rats was reversible by administration of buprenorphrine (p=0.029), it suggested that the detected gait changes were associated with pain. Comparisons of end-point and follow-up studies revealed the confounding effects of training, which led to higher gait velocities and probably a different adaptive response to tendon pain in the trained rats. The results showed that motion analysis could be used to measure activity-related chronic tendon pain.

  9. Bifocal osseous avulsion of the patellar tendon from the distal patella and tibial tuberosity in a child.

    PubMed

    Hermansen, Lars L; Freund, Knud G

    2016-03-01

    This case report describes a 12-year-old boy, who suffered an injury to the right knee in a skateboard accident. Radiographs and surgery confirmed the extremely rare bifocal avulsion fracture including the distal patellar pole and tibial tuberosity. Open reduction and internal fixation was accomplished, and 4-month follow-up demonstrated a good outcome.

  10. High-Tensile Strength Tape Versus High-Tensile Strength Suture: A Biomechanical Study.

    PubMed

    Gnandt, Ryan J; Smith, Jennifer L; Nguyen-Ta, Kim; McDonald, Lucas; LeClere, Lance E

    2016-02-01

    To determine which suture design, high-tensile strength tape or high-tensile strength suture, performed better at securing human tissue across 4 selected suture techniques commonly used in tendinous repair, by comparing the total load at failure measured during a fixed-rate longitudinal single load to failure using a biomechanical testing machine. Matched sets of tendon specimens with bony attachments were dissected from 15 human cadaveric lower extremities in a manner allowing for direct comparison testing. With the use of selected techniques (simple Mason-Allen in the patellar tendon specimens, whip stitch in the quadriceps tendon specimens, and Krackow stitch in the Achilles tendon specimens), 1 sample of each set was sutured with a 2-mm braided, nonabsorbable, high-tensile strength tape and the other with a No. 2 braided, nonabsorbable, high-tensile strength suture. A total of 120 specimens were tested. Each model was loaded to failure at a fixed longitudinal traction rate of 100 mm/min. The maximum load and failure method were recorded. In the whip stitch and the Krackow-stitch models, the high-tensile strength tape had a significantly greater mean load at failure with a difference of 181 N (P = .001) and 94 N (P = .015) respectively. No significant difference was found in the Mason-Allen and simple stitch models. Pull-through remained the most common method of failure at an overall rate of 56.7% (suture = 55%; tape = 58.3%). In biomechanical testing during a single load to failure, high-tensile strength tape performs more favorably than high-tensile strength suture, with a greater mean load to failure, in both the whip- and Krackow-stitch models. Although suture pull-through remains the most common method of failure, high-tensile strength tape requires a significantly greater load to pull-through in a whip-stitch and Krakow-stitch model. The biomechanical data obtained in the current study indicates that high-tensile strength tape may provide better repair strength compared with high-tensile strength suture at time-zero simulated testing. Published by Elsevier Inc.

  11. [Isokinetic assessment with two years follow-up of anterior cruciate ligament reconstruction with patellar tendon or hamstring tendons].

    PubMed

    Condouret, J; Cohn, J; Ferret, J-M; Lemonsu, A; Vasconcelos, W; Dejour, D; Potel, J-F

    2008-12-01

    This retrospective multicentric study was designed to assess the outcome of quadriceps and hamstrings muscles two years after Anterior Cruciate Ligament (ACL) reconstruction and compare muscles recovery depending on the type of graft and individual variables like age, gender, level of sport, but also in terms of discomfort, pain and functional score. The results focused on the subjective and objective IKDC scores, SF36, the existence or not of subjective disorders and their location. The review included isokinetic muscle tests concentric and eccentric extensors/flexors but also internal rotators/external rotators with analysis of mean work and mean power. One hundred and twenty-seven patients were included with an average age 29 years (+/-10). They all had an ACL reconstruction with patellar tendon or hamstring tendon with single or double bundles. In the serie, the average muscles deficit at two years was 10% for the flexors and extensors but with a significant dispersion. Significant differences were not noted in the mean values of all parameters in term of sex or age (over 30 years or not), neither the type of sport, nor of clinical assessment (Class A and B of objective IKDC score), nor the existence of anterior knee pain. There was a relationship between the level of extensor or flexor recovery and the quality of functional results with minimal muscle deficits close to 5% if the IKDC score was over 90 and deficits falling to 15% in the group with IKDC score less than 90. The type of reconstruction (patellar tendon versus hamstrings) had an influence on the muscle deficit. For extensors, the recovery was the same in the two groups, more than 90% at two years and the distribution of these two populations by level of deficit was quite the same. For flexors, residual deficits were significantly higher in the hamstrings group on the three studied parameters whatever the speed and the type of contraction (concentric or eccentric) with an average deficit of 14 to 18%, while, in the patellar tendon group, there was a dominance over the opposite side of 2 to 3% in concentric contraction. The hamstrings deficit appears to be "harvest dependent". For internal rotators, a significantly higher deficit is observed in eccentric contraction for the hamstrings group. The residual hamstrings deficits were related to the number of tendons harvested: -7% when there was no harvest, 7% with one tendon harvested and 17% with two tendons harvested. The relationship between the level of recovery of the quadriceps muscle and hamstrings at two years and the quality of functional results incite, regarding the significantly higher deficit of flexors in ACL reconstructions with hamstrings, to change the rehabilitation programs and especially on early rehabilitation of hamstrings in eccentric mode in the early weeks postoperative considering the harvest site as an equivalent of muscle tear.

  12. RANDOMIZED PROSPECTIVE STUDY ON TRAUMATIC PATELLAR DISLOCATION: CONSERVATIVE TREATMENT VERSUS RECONSTRUCTION OF THE MEDIAL PATELLOFEMORAL LIGAMENT USING THE PATELLAR TENDON, WITH A MINIMUM OF TWO YEARS OF FOLLOW-UP.

    PubMed

    Bitar, Alexandre Carneiro; D'Elia, Caio Oliveira; Demange, Marco Kawamura; Viegas, Alexandre Christo; Camanho, Gilberto Luis

    2011-01-01

    The aim of this study was to compare the surgical results from reconstruction of the medial patellofemoral ligament (MPFL) with non-operative treatment of primary patellar dislocation. Thirty-nine patients (41 knees) with patellar dislocation were randomized into two groups. One group was treated conservatively (immobilization and physiotherapy) and other was treated surgically with reconstruction of the MPFL, and the results were evaluated with a minimum follow-up of two years. The Kujala questionnaire was applied to assess pain and quality of life, and recurrences were evaluated. Pearson's chi-square test and Fisher's exact test were used in the statistical evaluation. The statistical analysis showed that the mean Kujala score was significantly lower in the conservative group (70.8), compared with the mean value in the surgical group (88.9), with p = 0.001. The surgical group presented a higher percentage of "good/excellent" Kujala score results (71.43%) than in the conservative group (25.0%), with p = 0.003. The conservative group presented a greater number of recurrences (35% of the cases), while in the surgical group there were no reports of recurrences and/or subluxation. Treatment with reconstruction of the medial patellofemoral ligament using the patellar tendon produced better results, based on the analysis of post-treatment recurrences and the better final results from the Kujala questionnaire after a minimum follow-up period of two years.

  13. Viscoelastic behavior of discrete human collagen fibrils.

    PubMed

    Svensson, René B; Hassenkam, Tue; Hansen, Philip; Peter Magnusson, S

    2010-01-01

    Whole tendon and fibril bundles display viscoelastic behavior, but to the best of our knowledge this property has not been directly measured in single human tendon fibrils. In the present work an atomic force microscopy (AFM) approach was used for tensile testing of two human patellar tendon fibrils. Fibrils were obtained from intact human fascicles, without any pre-treatment besides frozen storage. In the dry state a single isolated fibril was anchored to a substrate using epoxy glue, and the end of the fibril was glued on to an AFM cantilever for tensile testing. In phosphate buffered saline, cyclic testing was performed in the pre-yield region at different strain rates, and the elastic response was determined by a stepwise stress relaxation test. The elastic stress-strain response corresponded to a second-order polynomial fit, while the viscous response showed a linear dependence on the strain. The slope of the viscous response showed a strain rate dependence corresponding to a power function of powers 0.242 and 0.168 for the two patellar tendon fibrils, respectively. In conclusion, the present work provides direct evidence of viscoelastic behavior at the single fibril level, which has not been previously measured.

  14. Effect of tendon vibration during wide-pulse neuromuscular electrical stimulation (NMES) on muscle force production in people with spinal cord injury (SCI).

    PubMed

    Bochkezanian, Vanesa; Newton, Robert U; Trajano, Gabriel S; Vieira, Amilton; Pulverenti, Timothy S; Blazevich, Anthony J

    2018-02-13

    Neuromuscular electrical stimulation (NMES) is commonly used in skeletal muscles in people with spinal cord injury (SCI) with the aim of increasing muscle recruitment and thus muscle force production. NMES has been conventionally used in clinical practice as functional electrical stimulation (FES), using low levels of evoked force that cannot optimally stimulate muscular strength and mass improvements, and thus trigger musculoskeletal changes in paralysed muscles. The use of high intensity intermittent NMES training using wide-pulse width and moderate-intensity as a strength training tool could be a promising method to increase muscle force production in people with SCI. However, this type of protocol has not been clinically adopted because it may generate rapid muscle fatigue and thus prevent the performance of repeated high-intensity muscular contractions in paralysed muscles. Moreover, superimposing patellar tendon vibration onto the wide-pulse width NMES has been shown to elicit further increases in impulse or, at least, reduce the rate of fatigue in repeated contractions in able-bodied populations, but there is a lack of evidence to support this argument in people with SCI. Nine people with SCI received two NMES protocols with and without superimposing patellar tendon vibration on different days (i.e. STIM and STIM+vib), which consisted of repeated 30 Hz trains of 58 wide-pulse width (1000 μs) symmetric biphasic pulses (0.033-s inter-pulse interval; 2 s stimulation train; 2-s inter-train interval) being delivered to the dominant quadriceps femoris. Starting torque was 20% of maximal doublet-twitch torque and stimulations continued until torque declined to 50% of the starting torque. Total knee extensor impulse was calculated as the primary outcome variable. Total knee extensor impulse increased in four subjects when patellar tendon vibration was imposed (59.2 ± 15.8%) but decreased in five subjects (- 31.3 ± 25.7%). However, there were no statistically significant differences between these sub-groups or between conditions when the data were pooled. Based on the present results there is insufficient evidence to conclude that patellar tendon vibration provides a clear benefit to muscle force production or delays muscle fatigue during wide-pulse width, moderate-intensity NMES in people with SCI. ACTRN12618000022268 . Date: 11/01/2018. Retrospectively registered.

  15. Etiology and pathophysiology of tendon ruptures in sports.

    PubMed

    Kannus, P; Natri, A

    1997-04-01

    Of all spontaneous tendon ruptures, complete Achilles tendon tears are most closely associated with sports activities (1-3). Schönbauer (3) reported that 75% of all ruptures of the Achilles tendon are related to sports. In Plecko & Passl (2) the number was 60%. In our material of 430 cases, the number of sports-related Achilles ruptures was very similar (62%), while only 2% of ruptures of other tendons were sports-related (P < 0.001) (1). Also, the majority of Achilles reruptures occurred in sports. The ruptures occurred most often in soccer (34%), track and field (16%) and basketball (14%). The distribution of Achilles ruptures according to different sports varies considerably from country to country, according to the national sport traditions. For example, in northern and middle Europe, soccer, tennis, track and field, indoor ball games, downhill skiing, and gymnastics are the most common; and in North America, football, basketball, baseball, tennis and downhill skiing dominate the statistics (1, 2, 4). In sports, some Achilles ruptures are not spontaneous or degeneration-induced but may occur as a consequence of the remarkably high forces that are involved in the performance (2). Ruptures in the high jump or triple jump are good examples. In such cases, failure in the neuromuscular protective mechanisms due to fatigue or disturbed co-ordination can frequently be found. The spontaneous complete rupture of the supraspinatus tendon of the rotator cuff does not occur very frequently in sports. Those sports that include high-energy throwing movements, such as American and Finnish baseball, American football, rugby and discuss and javelin throwing, may, however, produce this injury. Partial tears and inflammations of the rotator cuff complex are much more frequent in throwing sports. The complete rupture of the proximal long head of the biceps brachii tendon is rare among competitive and recreational athletes. In our material, under 2% of these ruptures were associated with sports activities (5). The rupture (avulsion) of the distal tendon of the biceps muscle is rare. In sports, gymnastics, body building and weight lifting have been said to be able to produce this injury (6). In general, complete ruptures of the quadriceps tendon and the patellar tendon occur most often in older individuals. In our study, the mean age of these patients was 65 years (5). However, these injuries do also occur in younger age groups, especially in athletes. In athletes, the rupture most frequently occurs in high-power sports events, such as high jump, basketball and weight lifting, at the age of 15-30 years. A chronic-patellar apicitis (jumper's knee) may predispose rupture of the tendon (7). As is the case with the rotator cuff complex, overuse inflammation and partial tears of the quadriceps and patellar tendons are one of the most characteristic athletic injuries. Complete spontaneous ruptures of other tendons in sports are rare, although the literature does provide case studies from almost every tendon the human body possesses (8-18).

  16. Jumper's Knee (Patellar Tendonitis)

    MedlinePlus

    ... knee to move, bend, straighten, provide strength to jump, and stabilize the leg for landing. About Jumper's ... medical professional will ask the person to run, jump, kneel, or squat to determine the level of ...

  17. Femoral press-fit fixation in ACL reconstruction using bone-patellar tendon-bone autograft: results at 15 years follow-up.

    PubMed

    Widuchowski, Wojciech; Widuchowska, Malgorzata; Koczy, Bogdan; Dragan, Szymon; Czamara, Andrzej; Tomaszewski, Wieslaw; Widuchowski, Jerzy

    2012-06-27

    If anterior cruciate ligament (ACL) reconstruction is to be performed, decision regarding graft choice and its fixation remains one of the most controversial. Multiple techniques for ACL reconstruction are available. To avoid disadvantages related to fixation devices, a hardware-free, press-fit ACL reconstruction technique was developed. The aim of this study was to evaluate clinical outcome and osteoarthritis progression in long term after ACL reconstruction with central third patellar-tendon autograft fixed to femur by press-fit technique. Fifty two patients met inclusion/excusion criteria for this study. The patients were assessed preoperatively and at 15 years after surgery with International Knee Documentation Committee Knee Ligament Evaluation Form, Lysholm knee score, Tegner activity scale and radiographs. Good overall clinical outcomes and self-reported assessments were documented, and remained good at 15 years. The mean Lysholm and Tegner scores improved from 59.7 ± 18.5 and 4.2 ± 1.0 preoperatively to 86.4 ± 5.6 (p = 0.004) and 6.9 ± 1.4 (p = 0.005) respectively at follow-up. The IKDC subjective score improved from 60.1 ± 9.2 to 80.2 ± 8.1 (p = 0.003). According to IKDC objective score, 75% of patients had normal or nearly normal knee joints at follow-up. Grade 0 or 1 results were seen in 85% of patients on laxity testing. Degenerative changes were found in 67% of patients. There was no correlation between arthritic changes and stability of knee and subjective evaluation (p > 0.05). ACL reconstruction with patellar tendon autograft fixed to femur with press-fit technique allows to achieve good self-reported assessments and clinical ligament evaluation up to 15 years. Advantages of the bone-patellar-tendon-bone (BPTB) press-fit fixation include unlimited bone-to-bone healing, cost effectiveness, avoidance of disadvantages associated with hardware, and ease for revision surgery. BPTB femoral press-fit fixation technique can be safely applied in clinical practice and enables patients to return to preinjury activities including high-risk sports.

  18. Ablating hedgehog signaling in tenocytes during development impairs biomechanics and matrix organization of the adult murine patellar tendon enthesis.

    PubMed

    Breidenbach, Andrew P; Aschbacher-Smith, Lindsey; Lu, Yinhui; Dyment, Nathaniel A; Liu, Chia-Feng; Liu, Han; Wylie, Chris; Rao, Marepalli; Shearn, Jason T; Rowe, David W; Kadler, Karl E; Jiang, Rulang; Butler, David L

    2015-08-01

    Restoring the native structure of the tendon enthesis, where collagen fibers of the midsubstance are integrated within a fibrocartilaginous structure, is problematic following injury. As current surgical methods fail to restore this region adequately, engineers, biologists, and clinicians are working to understand how this structure forms as a prerequisite to improving repair outcomes. We recently reported on the role of Indian hedgehog (Ihh), a novel enthesis marker, in regulating early postnatal enthesis formation. Here, we investigate how inactivating the Hh pathway in tendon cells affects adult (12-week) murine patellar tendon (PT) enthesis mechanics, fibrocartilage morphology, and collagen fiber organization. We show that ablating Hh signaling resulted in greater than 100% increased failure insertion strain (0.10 v. 0.05 mm/mm, p<0.01) as well as sub-failure biomechanical deficiencies. Although collagen fiber orientation appears overtly normal in the midsubstance, ablating Hh signaling reduces mineralized fibrocartilage by 32%, leading to less collagen embedded within mineralized tissue. Ablating Hh signaling also caused collagen fibers to coalesce at the insertion, which may explain in part the increased strains. These results indicate that Ihh signaling plays a critical role in the mineralization process of fibrocartilaginous entheses and may be a novel therapeutic to promote tendon-to-bone healing. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  19. MRI quantitative morphologic analysis of patellofemoral region: lack of correlation with chondromalacia patellae at surgery.

    PubMed

    Endo, Yoshimi; Schweitzer, Mark E; Bordalo-Rodrigues, Marcelo; Rokito, Andrew S; Babb, James S

    2007-11-01

    In numerous studies, the morphologic features of the patellofemoral joint have been analyzed on radiographs. The objective of this study was to assess patellofemoral measurements on MR images and to correlate the measurements with the presence or absence of chondromalacia patellae confirmed at surgery. Axial and sagittal MR images of 98 knees (97 patients) were evaluated. Lateral and medial patellar facet lengths, lateral-to-medial facet length ratio, and interfacet angle were measured at three levels through the patella. Trochlear depth was measured on an axial slice. Patella and patellar tendon lengths, patellar tendon-to-patella ratio, and overlap of the patellar and trochlear articular cartilages were measured on sagittal slices. These measurements in knees with chondromalacia patellae were compared with those in knees without chondromalacia patellae. For assessment of reproducibility, axial measurements were repeated by a second observer. There was no statistically significant difference in any of the axial and sagittal slice measurements between knees with and those without chondromalacia patellae. Interobserver reliability was excellent for measurements of trochlear depth and measurements in the superior and middle aspects of the patella. Measurements through the inferior patella were slightly less reproducible. The results of our study with MRI confirmed many previous radiographic findings. Although we did not find correlation between the presence of chondromalacia patellae and the patellofemoral indexes we analyzed, it is possible that the results of further investigations incorporating different grades of chondromalacia and different locations along the patellar articular surface may lead to further insight regarding the morphologic risk factors for chondromalacia patellae.

  20. Robot-aided in vitro measurement of patellar stability with consideration to the influence of muscle loading.

    PubMed

    Lorenz, Andrea; Bobrowitsch, Evgenij; Wünschel, Markus; Walter, Christian; Wülker, Nikolaus; Leichtle, Ulf G

    2015-07-23

    Anterior knee pain is often associated with patellar maltracking and instability. However, objective measurement of patellar stability under clinical and experimental conditions is difficult, and muscular activity influences the results. In the present study, a new experimental setting for in vitro measurement of patellar stability was developed and the mediolateral force-displacement behavior of the native knee analyzed with special emphasis on patellar tilt and muscle loading. In the new experimental setup, two established testing methods were combined: an upright knee simulator for positioning and loading of the knee specimens, and an industry robot for mediolateral patellar displacement. A minimally invasive coupling and force control mechanism enabled unconstrained motion of the patella as well as measurement of patellar motion in all six degrees of freedom via an external ultrasonic motion-tracking system. Lateral and medial patellar displacement were measured on seven fresh-frozen human knee specimens in six flexion angles with varying muscle force levels, muscle force distributions, and displacement forces. Substantial repeatability was achieved for patellar shift (ICC(3,1) = 0.67) and tilt (ICC(3,1) = 0.75). Patellar lateral and medial shift decreased slightly with increasing flexion angle. Additional measurement of patellar tilt provided interesting insights into the different displacement mechanisms in lateral and medial directions. For lateral displacement, the patella tilted in the same (lateral) direction, and tilted in the opposite direction (again laterally) for medial displacement. With regard to asymmetric muscle loading, a significant influence (p < 0.03, up to 5 mm shift and 8° tilt) was found for lateral displacement and a reasonable relationship between muscle and patellar force, whereas no effect was visible in the medial direction. The developed experimental setup delivered reproducible results and was found to be an excellent testing method for the in vitro analysis of patellar stability and future investigation of surgical techniques for patellar stabilization and total knee arthroplasty. We demonstrated a significant influence of asymmetric quadriceps loading on patellar stability. In particular, increased force application on the vastus lateralis muscle led to a clear increase of lateral patellar displacement.

  1. Effect of Medial Patellofemoral Ligament Reconstruction Method on Patellofemoral Contact Pressures and Kinematics.

    PubMed

    Stephen, Joanna M; Kittl, Christoph; Williams, Andy; Zaffagnini, Stefano; Marcheggiani Muccioli, Giulio Maria; Fink, Christian; Amis, Andrew A

    2016-05-01

    There remains a lack of evidence regarding the optimal method when reconstructing the medial patellofemoral ligament (MPFL) and whether some graft constructs can be more forgiving to surgical errors, such as overtensioning or tunnel malpositioning, than others. The null hypothesis was that there would not be a significant difference between reconstruction methods (eg, graft type and fixation) in the adverse biomechanical effects (eg, patellar maltracking or elevated articular contact pressure) resulting from surgical errors such as tunnel malpositioning or graft overtensioning. Controlled laboratory study. Nine fresh-frozen cadaveric knees were placed on a customized testing rig, where the femur was fixed but the tibia could be moved freely from 0° to 90° of flexion. Individual quadriceps heads and the iliotibial tract were separated and loaded to 205 N of tension using a weighted pulley system. Patellofemoral contact pressures and patellar tracking were measured at 0°, 10°, 20°, 30°, 60°, and 90° of flexion using pressure-sensitive film inserted between the patella and trochlea, in conjunction with an optical tracking system. The MPFL was transected and then reconstructed in a randomized order using a (1) double-strand gracilis tendon, (2) quadriceps tendon, and (3) tensor fasciae latae allograft. Pressure maps and tracking measurements were recorded for each reconstruction method in 2 N and 10 N of tension and with the graft positioned in the anatomic, proximal, and distal femoral tunnel positions. Statistical analysis was undertaken using repeated-measures analyses of variance, Bonferroni post hoc analyses, and paired t tests. Anatomically placed grafts during MPFL reconstruction tensioned to 2 N resulted in the restoration of intact medial joint contact pressures and patellar tracking for all 3 graft types investigated (P > .050). However, femoral tunnels positioned proximal or distal to the anatomic origin resulted in significant increases in the mean medial joint contact pressure, medial patellar tilt, and medial patellar translation during knee flexion or extension, respectively (P < .050), regardless of graft type, as did tensioning to 10 N. The importance of the surgical technique, specifically correct femoral tunnel positioning and graft tensioning, in restoring normal patellofemoral joint (PFJ) kinematics and articular cartilage contact stresses is evident, and the type of MPFL graft appeared less important. The correct femoral tunnel position and graft tension for restoring normal PFJ kinematics and articular cartilage contact stresses appear to be more important than graft selection during MPFL reconstruction. These findings emphasize the importance of the surgical technique when undertaking this procedure. © 2016 The Author(s).

  2. Jumper's Knee (Patellar Tendonitis) (For Parents)

    MedlinePlus

    ... knee to move, bend, straighten, provide strength to jump, and stabilize the leg for landing. About Jumper's ... medical professional will ask the patient to run, jump, kneel, or squat to determine the level of ...

  3. Extended healing validation of an artificial tendon to connect the quadriceps muscle to the Tibia: 180-day study.

    PubMed

    Melvin, Alan J; Litsky, Alan S; Mayerson, Joel L; Stringer, Keith; Juncosa-Melvin, Natalia

    2012-07-01

    Whenever a tendon or its bone insertion is disrupted or removed, existing surgical techniques provide a temporary connection or scaffolding to promote healing, but the interface of living to non-living materials soon breaks down under the stress of these applications, if it must bear the load more than acutely. Patients are thus disabled whose prostheses, defect size, or mere anatomy limit the availability or outcomes of such treatments. Our group developed the OrthoCoupler™ device to join skeletal muscle to prosthetic or natural structures without this interface breakdown. In this study, the goat knee extensor mechanism (quadriceps tendon, patella, and patellar tendon) was removed from the right hind limb in 16 goats. The device connected the quadriceps muscle to a stainless steel bone plate on the tibia. Mechanical testing and histology specimens were collected from each operated leg and contralateral unoperated control legs at 180 days. Maximum forces in the operated leg (vs. unoperated) were 1,400 ± 93 N (vs. 1,179 ± 61 N), linear stiffnesses were 33 ± 3 N/mm (vs. 37 ± 4 N/mm), and elongations at failure were 92.1 ± 5.3 mm (vs. 68.4 ± 3.8 mm; mean ± SEM). Higher maximum forces (p = 0.02) and elongations at failure (p=0.008) of legs with the device versus unoperated controls were significant; linear stiffnesses were not (p=0.3). We believe this technology will yield improved procedures for clinical challenges in orthopedic oncology, revision arthroplasty, tendon transfer, and tendon injury reconstruction. Copyright © 2011 Orthopaedic Research Society.

  4. VGluT2 expression in painful Achilles and patellar tendinosis: evidence of local glutamate release by tenocytes.

    PubMed

    Scott, Alexander; Alfredson, Håkan; Forsgren, Sture

    2008-05-01

    The pathogenesis of chronic tendinopathy is unclear. We have previously measured high intratendinous levels of glutamate in patients with tendinosis, suggesting potential roles of glutamate in the modulation of pain, vascular function, and degenerative changes including apoptosis of tenocytes. However, the origin of free glutamate found in tendon tissue is completely unknown. Surgical biopsies of pain-free normal tendons and tendinosis tendons (Achilles and patellar) were examined immunohistochemically using antibodies against vesicular glutamate transporters (VGluT1 and VGluT2), as indirect markers of glutamate release. In situ hybridization for VGluT2 mRNA was also conducted. Specific immunoreactions for VGluT2, but not VGluT1, could be consistently detected in tenocytes. However, there were interindividual variations in the levels of immunoreactivity. The level of immunoreaction for VGluT2 was higher in tendinosis tendons compared to normal tendons (p < 0.05). In situ hybridization of VGluT2 demonstrated that mRNA was localized in a similar pattern as the protein, with marked expression by certain tenocytes, particularly those showing abnormal appearances. Reactivity for VGluT1 and -2 was absent from nerves and vessel structures in both normal and painful tendons. The current data demonstrate that tenocytes may be involved in the regulation of extracellular glutamate levels in tendons. Specifically, the observations suggest that free glutamate may be locally produced and released by tenocytes, rather than by peripheral neurons. Excessive free glutamate is expected to impact a variety of autocrine and paracrine functions important in the development of tendinosis, including tenocyte proliferation and apoptosis, extracellular matrix metabolism, nociception, and blood flow. (c) 2007 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  5. Arthroscopic treatment of chronic patellar tendinopathy in high-level athletes

    PubMed Central

    Alaseirlis, Dimosthenis Artemis; Konstantinidis, George Athanasios; Malliaropoulos, Nikolaos; Nakou, Lamprini Stefanos; Korompilias, Anastasios; Maffulli, Nicola

    2012-01-01

    Summary To present the results of arthroscopic treatment of patellar tendinopathy in high-level competition athletes. Eleven high-level athletes presented chronic patellar tendinopathy which did not respond to long term conservative treatment. Average age of the patients was 24.8 ±3.4 years old. All patients received an arthroscopic procedure with osteoplasty of the distal patellar pole, debridement of the underlying Hoffa fat pad and of the degenerated areas of the proximal posterior patella tendon and cauterization of the visible neo-vessels. Mean duration of follow-up was 17.4±4 months. Patients showed a major improvement in the Lysholm score from 49.9±5.2 to 92.5±7 and in the VISA P score from 41.2±5.2 to 86.8±14.9 on tenth post-operative week. All patients had returned to sports activities by the twelfth postoperative week. Arthroscopic treatment of chronic patellar tendinopathy found to be a minimal invasive and safe technique which produced satisfactory results. PMID:23738308

  6. Quantitative assessment of patellar vascularity following bone-patellar tendon-bone autograft harvest for ACL reconstruction.

    PubMed

    Jones, Kristofer J; Lazaro, Lionel E; Taylor, Samuel A; Pardee, Nadine C; Dyke, Jonathan P; Hannafin, Jo A; Warren, Russell F; Lorich, Dean G

    2016-09-01

    Recent anatomic studies have suggested that the dominant arterial supply of the patella enters through the inferior pole. Based upon these findings, we hypothesized that bone-patellar tendon-bone graft harvest can significantly diminish patellar vascularity. Nine matched pair cadaveric knee specimens (mean age 47.4 years) were dissected and cannulated. A single knee was selected to undergo routine graft harvest, and the contralateral knee was left intact to serve as a control. Gadolinium was injected, and magnetic resonance imaging (MRI) signal enhancement was quantified to determine differences in uptake. Each matched pair was subsequently injected with a urethane polymer compound and dissected to correlate vessel disruption with MRI findings. We identified two predominating patterns of vessel entry. In one pattern, the vessel entered the inferomedial aspect (five o'clock/right, seven o'clock/left) of the patella and was disrupted by graft harvest in 2/9 (22.2 %) pairs. In the second pattern, the vessel entered further medial (four o'clock/right, eight o'clock/left) and was not disrupted (7/9, 78.8 %). The mean decrease in gadolinium uptake following disruption of the predominant vessel measured 56.2 % (range 42.6-69.5 %) compared to an average decrease of 18.3 % (range 7.1-29.1 %) when the dominant arterial supply to the inferior pole remained intact (p < 0.04). Medial entry of the predominant vessel precluded vessel disruption. Disruption of the dominant arterial supply can result in a significant decrease in patellar vascularity. Modification of graft harvest techniques and areas of surgical dissection should be explored to minimize vascular insult. Further correlation with clinical studies/outcomes is necessary to determine a potential association between vascular insult and anterior knee pain.

  7. Patellar fixation protected with a load-sharing cable: a mechanical and clinical study.

    PubMed

    Perry, C R; McCarthy, J A; Kain, C C; Pearson, R L

    1988-01-01

    The stability of patellar fracture fixation protected with a load-sharing cable was studied in cadavers. A transverse patellar osteotomy was produced and stabilized with standard patellar fixation with or without a figure-of-eight cable that extends from the proximal pole of the patella to the tibial tubercle. Standard fixation techniques (interfragmentary cancellous screws or modified tension-band wiring) alone failed after significantly fewer cycles of flexion and extension than did the same fixation when supplemented with a load-sharing cable. In the clinical evaluation of the load-sharing cable, 14 consecutive patients with displaced patellar fractures were treated. No immobilization was used and the patients were started on passive and active range of motion and weight-bearing ambulation in the early postoperative period. Thirteen fractures healed uneventfully. The increased stability of patellar fracture fixation protected with a load-sharing cable offers three advantages: (a) adjunctive casting is unnecessary, (b) comminuted fractures can be "pieced" together anatomically with less concern for loss of fixation, and (c) early postoperative passive and active range of motion can be achieved.

  8. Soft-tissue allografts terminally sterilized with an electron beam are biomechanically equivalent to aseptic, nonsterilized tendons.

    PubMed

    Elenes, Egleide Y; Hunter, Shawn A

    2014-08-20

    Allograft safety is contingent on effective sterilization. However, current sterilization methods have been associated with decreased biomechanical strength and higher failure rates of soft-tissue allografts. In this study, electron beam (e-beam) sterilization was explored as an alternative sterilization method to preserve biomechanical integrity. We hypothesized that e-beam sterilization would not significantly alter the biomechanical properties of tendon allograft compared with aseptic, nonsterilized controls and gamma-irradiated grafts. Separate sets of forty fresh-frozen tibialis tendon allografts (four from each of ten donors) and forty bisected bone-patellar tendon-bone (BTB) allografts (four from each of ten donors) were randomly assigned to four study groups. One group received a 17.1 to 21.0-kGy gamma radiation dose; two other groups were sterilized with an e-beam at either a high (17.1 to 21.0-kGy) or low (9.2 to 12.2-kGy) dose. A fourth group served as nonsterilized controls. Each graft was cyclically loaded to 200 N of tension for 2000 cycles at a frequency of 2 Hz, allowed to relax for five minutes, and then tested in tension until failure at a 100%/sec strain rate. One-way analysis of variance testing was used to identify significant differences. Tibialis tendons sterilized with both e-beam treatments and with gamma irradiation exhibited values for cyclic tendon elongation, maximum load, maximum displacement, stiffness, maximum stress, maximum strain, and elastic modulus that were not significantly different from those of nonsterilized controls. BTB allografts sterilized with the high e-beam dose and with gamma irradiation were not significantly different in cyclic tendon elongation, maximum load, maximum displacement, stiffness, maximum stress, maximum strain, and elastic modulus from nonsterilized controls. BTB allografts sterilized with the e-beam at the lower dose were significantly less stiff than nonsterilized controls (p = 0.014) but did not differ from controls in any other properties. The difference in stiffness likely resulted from variations in tendon size rather than the treatments, as the elastic moduli of the groups were similar. The biomechanical properties of tibialis and BTB allografts sterilized with use of an e-beam at a dose range of 17.1 to 21.0 kGy were not different from those of aseptic, nonsterilized controls or gamma-irradiated allografts. E-beam sterilization can be a viable method to produce safe and biomechanically uncompromised soft-tissue allografts. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.

  9. Patellar tendinopathy: late-stage results from surgical treatment☆

    PubMed Central

    Cenni, Marcos Henrique Frauendorf; Silva, Thiago Daniel Macedo; do Nascimento, Bruno Fajardo; de Andrade, Rodrigo Cristiano; Júnior, Lúcio Flávio Biondi Pinheiro; Nicolai, Oscar Pinheiro

    2015-01-01

    Objective To evaluate the late-stage results from surgical treatment of patellar tendinopathy (PT), using the Visa score (Victorian Institute of Sport Tendon Study Group) and the Verheyden method. Methods This was a retrospective study in which the postoperative results from 12 patients (14 knees) who were operated between July 2002 and February 2011 were evaluated. The patients included in the study presented patellar tendinopathy that was refractory to conservative treatment, without any other concomitant lesions. Patients who were not properly followed up during the postoperative period were excluded. Results Using the Verheyden method, nine patients were considered to have very good results, two had good results and one had poor results. In relation to Visa, the mean was 92.4 points and only two patients had scores less than 70 points (66 and 55 points). Conclusion When surgical treatment for patellar tendinopathy is correctly indicated, it has good long-term results. PMID:26535202

  10. Effects of Initial Graft Tension on the Tibiofemoral Compressive Forces and Joint Position Following ACL Reconstruction

    PubMed Central

    Brady, Mark F.; Bradley, Michael P.; Fleming, Braden C.; Fadale, Paul D.; Hulstyn, Michael J.; Banerjee, Rahul

    2007-01-01

    Background The initial tension applied to an ACL graft at the time of fixation modulates knee motion and the tibiofemoral compressive loads. Purpose To establish the relationships between initial graft tension, tibiofemoral compressive force, and the neutral tibiofemoral position in the cadaver knee. Study Design Controlled Laboratory Study. Methods The tibiofemoral compressive forces and joint positions were determined in the ACL-intact knee at 0°, 20° and 90° knee flexion. The ACL was excised and reconstructed with a patellar tendon graft using graft tensions of 1, 15, 30, 60 and 90 N applied at 0°, 20° and 90° knee flexion. The compressive forces and neutral positions were compared between initial tension conditions and the ACL-intact knee. Results Increasing initial graft tension increased the tibiofemoral compressive forces. The forces in the medial compartment were 1.8 times those in the lateral compartment. The compressive forces were dependent on the knee angle at which the tension was applied. The greatest compressive forces occurred when the graft was tensioned with the knee in extension. An increase in initial graft tension caused the tibia to rotate externally compared to the ACL-intact knee. Increases in initial graft tension also caused a significant posterior translation of the tibia relative to the femur. Conclusions Different initial graft tension protocols produced predictable changes in the tibiofemoral compressive forces and joint positions. Clinical Relevance The tibiofemoral compressive force and neutral joint position were best replicated with a low graft tension (1–15 N) when using a patellar tendon graft. PMID:17218659

  11. Functional results from reconstruction of the anterior cruciate ligament using the central third of the patellar ligament and flexor tendons☆

    PubMed Central

    de Souza Leao, Marcos George; Pampolha, Abelardo Gautama Moreira; Orlando Junior, Nilton

    2015-01-01

    Objectives To evaluate knee function in patients undergoing reconstruction of the anterior cruciate ligament (ACL) using the central third of the patellar ligament or the medial flexor tendons of the knee, i.e. quadruple ligaments from the semitendinosus and gracilis (ST-G), by means of the Knee Society Score (KSS) and the Lysholm scale. Methods This was a randomized prospective longitudinal study on 40 patients who underwent arthroscopic ACL reconstruction between September 2013 and August 2014. They comprised 37 males and three females, with ages ranging from 16 to 52 years. The patients were numbered randomly from 1 to 40: the even numbers underwent surgical correction using the ST-G tendons and the odd numbers, using the patellar tendon. Functional evaluations were made using the KSS and Lysholm scale, applied in the evening before the surgical procedure and six months after the operation. Results From the statistical analysis, it could be seen that the patients’ functional capacity was significantly greater after the operation than before the operation. There was strong evidence that the two forms of therapy had similar results (p = >0.05), in all the comparisons. Conclusions The results from the ACL reconstructions were similar with regard to functional recovery of the knee and improvement of quality of life, independent of the type of graft. It was not possible to identify the best method of surgical treatment. The surgeon's clinical and technical experience and the patient are the factors that determine the choice of graft type for use in ACL surgery. PMID:27218084

  12. Has platelet-rich plasma any role in anterior cruciate ligament allograft healing?

    PubMed

    Nin, Juan Ramón Valentí; Gasque, Gonzalo Mora; Azcárate, Andrés Valentí; Beola, Jesús Dámaso Aquerreta; Gonzalez, Milagros Hernandez

    2009-11-01

    The aim of this study was to evaluate and compare the clinical and inflammatory parameters with the addition of platelet-derived growth factor (PDGF) in primary anterior cruciate ligament (ACL) reconstruction with bone-patellar tendon-bone allograft. We prospectively randomized 100 patients undergoing arthroscopic patellar tendon allograft ACL reconstruction to a group in whom platelet-enriched gel was used (n = 50) and a non-gel group (n = 50). The platelet concentration was 837 x 10(3)/mm(3), and the gel was introduced inside the graft and the tibial tunnel. Demographic data were comparable between groups. The mean follow-up was 24 months for both groups and included a history, clinical evaluation with the International Knee Documentation Committee score, radiographs, and magnetic resonance imaging. There were no differences in the number of associated injuries. The results did not show any statistically significant differences between the groups for inflammatory parameters (perimeters of the knee and C-reactive protein level), magnetic resonance imaging appearance of the graft, and clinical evaluation scores (visual analog scale, International Knee Documentation Committee, and KT-1000 arthrometer [MEDmetric, San Diego, CA]). At this time, the therapeutic role of PDGF in ACL reconstruction remains unclear. The use of PDGF, on the graft and inside the tibial tunnel, in patients treated with bone-patellar tendon-bone allografts has no discernable clinical or biomechanical effect at 2 years' follow-up. More clinical studies will be needed to show the efficacy and use of these factors in daily practice in ACL reconstruction. Level I, prospective, randomized, double-blind study.

  13. Revision anterior cruciate ligament reconstruction with nonirradiated fresh-frozen patellar tendon allograft.

    PubMed

    Fox, Jeff A; Pierce, Mark; Bojchuk, John; Hayden, Jennifer; Bush-Joseph, Charles A; Bach, Bernard R

    2004-10-01

    To evaluate the effectiveness of a revision anterior cruciate ligament reconstruction with nonirradiated patellar tendon allograft used to salvage a failed index patellar tendon autograft procedure. Retrospective case series with minimum 2-year follow-up. Between 1993 and 1999, 39 patients underwent a revision reconstruction. Clinical, radiographic, arthrometric, and functional evaluations were performed. The Tegner, Lysholm, Noyes, Knee Injury and Osteoarthritis Outcome Score (KOOS), International Knee Documentation Committee (IKDC), and SF-12 rating scales were used. Statistical analysis was conducted with our Biostatistics Department. Thirty-two of 38 patients (84%) were personally evaluated. The mean patient age was 28 years (range, 16 to 57 years); the mean follow-up was 4.8 years (range, 2.1 to 12.1 years). After revision, there were significant improvements in the Lachman and pivot-shift test results: 87% had a grade 0/1+ Lachman and a 0/1+ pivot-shift. However, 25% had a grade 1+ pivot-shift. Postoperatively, KT-1000 testing revealed that 84% had a maximum manual side-to-side difference of < or =3 mm and 6% had >5 mm. Functional testing revealed a mean 4% difference in side-to-side comparisons for a single-leg hop for distance and time, as well as vertical jump. The mean results of Noyes sports function (72), Lysholm (75), Tegner (6.3), KOOS sports activity scale (67), SF-12 physical component (48), SF-12 mental component (55), and IKDC (71) were obtained. The Noyes sports activity score showed a significant improvement from 55 preoperatively to 70 at follow-up. Subjectively, 87% of patients indicated that they were completely or mostly satisfied with the surgical outcome. One patient required another revision. The 2- to 11-year follow-up showed that the results of revision ACL reconstruction with a nonirradiated patellar tendon allograft were less favorable than those of a primary anterior cruciate ligament reconstruction, with a lower subjective satisfaction level and a higher percentage of patients with grade 1+ or higher pivot-shift results. However, when compared with previously published reports, our results were comparable and underscore that revision anterior cruciate ligament surgery should be approached with tempered enthusiasm and careful preoperative counseling, and considered as a salvage procedure. Level IV.

  14. National Rugby League athletes and tendon tap reflex assessment: a matched cohort clinical study.

    PubMed

    Maurini, James; Ohmsen, Paul; Condon, Greg; Pope, Rodney; Hing, Wayne

    2016-11-04

    Limited research suggests elite athletes may differ from non-athletes in clinical tendon tap reflex responses. In this matched cohort study, 25 elite rugby league athletes were compared with 29 non-athletes to examine differences in tendon reflex responses. Relationships between reflex responses and lengths of players' careers were also examined. Biceps, triceps, patellar and Achilles tendon reflexes were clinically assessed. Right and left reflexes were well correlated for each tendon (r S  = 0.7-0.9). The elite rugby league athletes exhibited significantly weaker reflex responses than non-athletes in all four tendons (p < 0.005). Biceps reflexes demonstrated the largest difference and Achilles reflexes the smallest difference. Moderate negative correlations (r S  = -0.3-0.6) were observed between reflex responses and lengths of players' careers. Future research is required to further elucidate mechanisms resulting in the observed differences in tendon reflexes and to ensure clinical tendon tap examinations and findings can be interpreted appropriately in this athletic population.

  15. [Systematic review about eccentric training in chronic patella tendinopathy].

    PubMed

    Lorenzen, J; Krämer, R; Vogt, P M; Knobloch, K

    2010-12-01

    Eccentric training has become a popular treatment for patellar tendinopathy. Aim of this review is to display different exercise prescriptions for patellar tendinopathy, to help clinicians make appropriate choices and identify areas needing further research. Is eccentric training as a conservative treatment in chronic patellar tendinopathy of beneficial effect versus other conservative treatments? According to the current scientific data, is it possible to recommend dosages and duration of training time of eccentric training? Systematic review of the current scientific literature on eccentric training as a conservative treatment in chronic Achilles tendinopathy according to the PRISMA-guidelines [Preferred Reporting Items for Systematic Reviews and Meta-Analyses]. National library of Medicine [NLM] between the years 1950 and 2010. Prospective randomised controlled trials (RCT). 7 articles with a total of 165 patients and in which eccentric training was one of the interventions, all published after 2000, were included. The median cohort study size was 20 subjects with a range from 15 to 35 subjects. Median follow-up duration was 12 weeks with a range from 4 to 12 weeks. Encouraging results, but variable study quality, with small numbers or short follow-up periods. The content of the different training programmes varied, but most were home-based programmes with twice daily training for 12 weeks. A number of potentially significant differences were identified in the eccentric programmes used: drop squats or slow eccentric movement, squatting on a 25° decline board or level ground, exercising into tendon pain or short of pain, loading the eccentric phase only or both phases, and progressing with speed then loading or simply loading. A pooled statistical evaluation of the included trials could not be performed due to different study designs as well as limited documentation of subjects' compliance. Most studies suggest that eccentric training may have a positive effect, but our ability to recommend a specific protocol is limited. The studies available indicate that the treatment programme should include a 25° decline board and should be performed with some level of discomfort, and that athletes should be removed from sports activity. However, these aspects need further study. Because of the heterogeneous outcome variables (ordinal scale, VAS, VISA-P) and the methodological limitations of the trials, no definite recommendation can be published concerning dosage and duration of eccentric training in chronic Patellar tendinopathy. © Georg Thieme Verlag KG Stuttgart · New York.

  16. Sleeve fracture of the adult patella: Case report and review of the literature.

    PubMed

    Xie, Linjun; Xu, Hong; Zhang, Lizhi; Xu, Rong; Guo, Yingkun

    2017-08-01

    The patellar fractures are common in adults, but rare in children. As a particular type of patellar fracture, however, sleeve fractures are almost always limited to children in the under 16's group. Herein, we report a rare case of a 19-year-old healthy adult female who presented sleeve fracture at the superior pole of the left patella. The clinical and radiological features are found including joint effusion, anterior tilt of the patella and a shell of bone lying proximally to the patella. Computed tomography and magnetic resonance imaging examination have been performed to further confirm the diagnosis of sleeve fracture, rupture of the quadriceps tendon and the cartilaginous injury. Under general anaesthesia, she underwent open surgical procedures for reconstituting anatomically the fracture and repairing the rupture of the quadriceps tendon. Six months after the operation, she could fully use her left knee without any pain and disability. Sleeve fractures of the patellar in adults are extremely rare, and our case is of interest for the first time occurring in healthy female adults. Our case report and literature review was aim to describe the clinic and imaging characteristics of superior pole sleeve fractures in adults, and highlight that physicians must be aware of this entity in adults so as to reduce misdiagnosis due to unfamiliarity.

  17. Severe valgus deformity of the knee with permanent patellar dislocation associated with melorheostosis: a case report and review of the literature.

    PubMed

    Kitta, Yuki; Niki, Yasuo; Udagawa, Kazuhiko; Enomoto, Hiroyuki; Toyama, Yoshiaki; Suda, Yasunori

    2014-03-01

    We present a case of an 8-year-old boy diagnosed with melorheostosis who was suffering from severe genu valgum, permanent dislocation of the patella, knee flexion contracture and leg length shortening. Soft tissue contracture of the limb and subsequent joint deformities were reported to represent clinical manifestations of pediatric melorheostosis. As the epiphyseal plate had not closed, patellar reduction was achieved by soft tissue surgical stabilization, including lateral retinacular release, medial retinaculum plication, and transfer of the lateral half of the patellar tendon. At 4 years postoperatively, as a result of improved limb alignment and knee flexion contracture, the leg length shortening has improved, and the patient does not limp and participates in sports activities. Surgical intervention should be performed as early as possible, because genu valgum and external rotation of the tibia may deteriorate with age, rendering the patellar dislocation irreversible in patients with melorheostosis before epiphyseal closure. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. FUNCTIONAL PERFORMANCE AND KNEE LAXITY IN NORMAL INDIVIDUALS AND IN INDIVIDUALS SUBMITTED TO ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION

    PubMed Central

    de Vasconcelos, Rodrigo Antunes; Bevilaqua-Grossi, Débora; Shimano, Antonio Carlos; Jansen Paccola, Cleber Antonio; Salvini, Tânia Fátima; Prado, Christiane Lanatovits; Mello Junior, Wilson A.

    2015-01-01

    The aim of this study was to analyze the correlation between deficits in the isokinetic peak torque of the knee extensors and flexors with hop tests, postoperative knee laxity and functional scores in normal and ACL- reconstructed subjects with patellar tendon and hamstring tendon autografts. Methods: Sixty male subjects were enrolled and subdivided into three groups: Twenty subjects without knee injuries (GC group) and two groups of 20 subjects submitted to ACL reconstruction with patellar tendon (GTP group) and hamstrings autograft (GTF group). Results: The results showed significant correlation between knee extensors peak torque and performance in the hop tests for GTF and GC groups. There are no significantly correlations between post op knee laxity and Lysholm score compared with the hop tests and peak torque deficits. Concerning the differences between groups, the GTP group showed greater peak torque deficits in knee extensors, worst Lysholm scores and higher percentage of individuals with lower limb symmetry index (ISM) < 90% in both hop tests when compared to the other two groups. Conclusion: It is not recommendable to use only one measurement instrument for the functional evaluation of ACL-reconstructed patients, because significant correlation between peak torque, subject's functional score, knee laxity and hop tests were not observed in all groups. PMID:26998464

  19. Effect of training and sudden detraining on the patellar tendon and its enthesis in rats

    PubMed Central

    2011-01-01

    Background Different conditions may alter tendon characteristics. Clinical evidence suggests that tendon injuries are more frequent in athletes that change type, intensity and duration of training. Aim of the study was the assessment of training and especially detraining on the patellar tendon (PT) and its enthesis. Methods 27 male adult Sprague-Dawley rats were divided into 3 groups: 20 rats were trained on a treadmill for 10 weeks. Of these, 10 rats were euthanized immediately after training (trained group), and 10 were caged without exercise for 4 weeks before being euthanized (de-trained group). The remaining 7 rats were used as controls (untrained rats). PT insertion, structure (collagen fiber organization and proteoglycan, PG, content), PT thickness, enthesis area, and subchondral bone volume at the enthesis were measured by histomorphometry and microtomography. Results Both PG content and collagen fiber organization were significantly lower in untrained and detrained animals than in trained ones (p < 0.05 and p < 0.0001). In the detrained group, fiber organization and PG content were worse than that of the untrained groups and the untrained group showed a significantly higher score than the detrained group (p < 0.05). In the trained group, the PT was significantly thicker than in untrained group (p < 0.05). No significant differences in the enthesis area and subchondral bone volume among the three groups were seen. Conclusions Moderate exercise exerts a protective effect on the PT structure while sudden discontinuation of physical activity has a negative effect on tendons. The present results suggest that after a period of sudden de-training (such as after an injury) physical activity should be restarted with caution and with appropriate rehabilitation programs. PMID:21247475

  20. Whey protein hydrolysate augments tendon and muscle hypertrophy independent of resistance exercise contraction mode.

    PubMed

    Farup, J; Rahbek, S K; Vendelbo, M H; Matzon, A; Hindhede, J; Bejder, A; Ringgard, S; Vissing, K

    2014-10-01

    In a comparative study, we investigated the effects of maximal eccentric or concentric resistance training combined with whey protein or placebo on muscle and tendon hypertrophy. 22 subjects were allocated into either a high-leucine whey protein hydrolysate + carbohydrate group (WHD) or a carbohydrate group (PLA). Subjects completed 12 weeks maximal knee extensor training with one leg using eccentric contractions and the other using concentric contractions. Before and after training cross-sectional area (CSA) of m. quadriceps and patellar tendon CSA was quantified with magnetic resonance imaging and a isometric strength test was used to assess maximal voluntary contraction (MVC) and rate of force development (RFD). Quadriceps CSA increased by 7.3 ± 1.0% (P < 0.001) in WHD and 3.4 ± 0.8% (P < 0.01) in PLA, with a greater increase in WHD compared to PLA (P < 0.01). Proximal patellar tendon CSA increased by 14.9 ± 3.1% (P < 0.001) and 8.1 ± 3.2% (P = 0.054) for WHD and PLA, respectively, with a greater increase in WHD compared to PLA (P < 0.05), with no effect of contraction mode. MVC and RFD increased by 15.6 ± 3.5% (P < 0.001) and 12-63% (P < 0.05), respectively, with no group or contraction mode effects. In conclusion, high-leucine whey protein hydrolysate augments muscle and tendon hypertrophy following 12 weeks of resistance training - irrespective of contraction mode. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. A systematic review of the use of platelet-rich plasma in sports medicine as a new treatment for tendon and ligament injuries.

    PubMed

    Taylor, Drew W; Petrera, Massimo; Hendry, Mike; Theodoropoulos, John S

    2011-07-01

    To evaluate, through a systematic review of the current literature, the evidence-based outcomes of the use of platelet-rich plasma (PRP) for the treatment of tendon and ligament injuries. A search of English-language articles was performed in PubMed and EMBASE using keywords "PRP," "platelet plasma," and "platelet concentrate" combined with "tendon" and then "ligament" independently. The search was conducted through September 2010. Search was limited to in vivo studies. Nonhuman studies were excluded. Tissue engineering strategies, which included a combination of PRP with additional cell types (bone marrow), were also excluded. Articles with all levels of evidence were included. Thirteen of 32 retrieved articles respected the inclusion criteria. The authors reviewed and tabulated data according to the year of study and journal, study type and level of evidence, patient demographics, method of PRP preparation, site of application, and outcomes. The selected studies focused on the application of PRP in the treatment of patellar and elbow tendinosis, Achilles tendon injuries, rotator cuff repair, and anterior cruciate ligament (ACL) reconstruction. Seven studies demonstrated favorable outcomes in tendinopathies in terms of improved pain and functional scores. In 3 studies on the use of PRP in ACL reconstruction, no statistically significant differences were seen with regard to clinical outcomes, tunnel widening, and graft integration. One study examined the systemic effects after the local PRP application for patellar and elbow tendinosis. Presently, PRP use in tendon and ligament injuries has several potential advantages, including faster recovery and, possibly, a reduction in recurrence, with no adverse reactions described. However, only 3 randomized clinical trials have been conducted.

  2. Sleeve fracture of the adult patella

    PubMed Central

    Xie, Linjun; Xu, Hong; Zhang, Lizhi; Xu, Rong; Guo, Yingkun

    2017-01-01

    Abstract Rationale: The patellar fractures are common in adults, but rare in children. As a particular type of patellar fracture, however, sleeve fractures are almost always limited to children in the under 16's group. Patient concerns: Herein, we report a rare case of a 19-year-old healthy adult female who presented sleeve fracture at the superior pole of the left patella. The clinical and radiological features are found including joint effusion, anterior tilt of the patella and a shell of bone lying proximally to the patella. Diagnoses: Computed tomography and magnetic resonance imaging examination have been performed to further confirm the diagnosis of sleeve fracture, rupture of the quadriceps tendon and the cartilaginous injury. Interventions: Under general anaesthesia, she underwent open surgical procedures for reconstituting anatomically the fracture and repairing the rupture of the quadriceps tendon. Outcomes: Six months after the operation, she could fully use her left knee without any pain and disability. Lessons: Sleeve fractures of the patellar in adults are extremely rare, and our case is of interest for the first time occurring in healthy female adults. Our case report and literature review was aim to describe the clinic and imaging characteristics of superior pole sleeve fractures in adults, and highlight that physicians must be aware of this entity in adults so as to reduce misdiagnosis due to unfamiliarity. PMID:28796028

  3. Effect of patellar strap and sports tape on pain in patellar tendinopathy: A randomized controlled trial.

    PubMed

    de Vries, A; Zwerver, J; Diercks, R; Tak, I; van Berkel, S; van Cingel, R; van der Worp, H; van den Akker-Scheek, I

    2016-10-01

    Numerous athletes with patellar tendinopathy (PT) use a patellar strap or sports tape during sports. This study's aim was to investigate the short-term effect of these orthoses on patellar tendon pain. Participants performed the single-leg decline squat, vertical jump test, and triple-hop test under four different conditions (patellar strap, sports tape, placebo, and control). Subsequently, participants practiced sports as usual for 2 weeks; during 1 week, they were assigned to one of the four conditions. Pain was measured with the visual analog scale (VAS). In total, 97 athletes with PT [61% male, age 27.0 (SD8.1), VISA-P 58.5 (SD12.7)] were analyzed. On the single-leg decline squat, the VAS pain score reduced significantly in the patellar strap (14 mm, P = 0.04) and the sports tape condition (13 mm, P = 0.04), compared with control, but not placebo. A significant decrease in VAS pain during sports was found in the sports tape (7 mm, P = 0.04) and placebo group (6 mm, P = 0.04). The VAS pain score two hours after sports decreased significantly in the patellar strap, sports tape and placebo group (8-mm, P < 0.001, 10 mm, P = 0.001 and 7 mm, P = 0.03, respectively). This study's findings indicate that an orthosis (including placebo tape) during sports can reduce pain in PT patients in the short term. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kleiner, J.B.; Amiel, D.; Harwood, F.L.

    A rabbit model for anterior cruciate ligament (ACL) reconstruction using autogenous patellar tendon was utilized to study the early events of autograft cellular dynamics. Biochemical, autoradiographic, histological, and vascular injection techniques demonstrated that the native autograft cell population rapidly necroses. This repopulation occurs without a vascular contribution; cells entering the autograft are reliant upon synovial fluid nutrition.

  5. Reliability and Validity of the Korean Version VISA-P Questionnaire for Patellar Tendinopathy in Adolescent Elite Volleyball Athletes.

    PubMed

    Park, Byung-Hyun; Seo, Jeong-Hwan; Ko, Myoung-Hwan; Park, Sung-Hee

    2013-10-01

    To translate the English Victorian Institute of Sport Assessment for patellar tendinopathy (VISA-P) questionnaire into a Korean version and to determine the reliability and validity of the Korean version. The English VISA-P questionnaire was translated into Korean according to the internationally recommended guidelines. Then, 28 adolescent elite volleyball athletes (average age, 16 years; range, 14 to 19 years) were asked to complete the questionnaire three times (before examination, after examination, and 1 week later) for reliability. They were evaluated through a physical examination and ultrasonography to diagnosis patellar tendinopathy. The internal consistency of the VISA-P questionnaire by Cronbach's alpha was 0.80 for the first, 0.78 for the second, and 0.79 for the third assessment. The intraclass correlation coefficient (ICC) between the first and second assessments was 0.97. The ICC between the second and third assessments was 0.96. The mean VISA-P scores were 67.6±15.7 for the patellar tendinopathy group (n=23) and 92.6±8.6 for the normal group (n=5). There were significantly lower VISA-P scores in the patellar tendinopathy group compared to the normal group. The translated Korean version VISA-P questionnaire has good internal consistency, test-retest reliability and validity. In addition, this study indicated that most adolescent elite volleyball athletes had patellar tendon problems. Therefore, the Korean version VISA-P is a useful self-administered outcome score of athletes with patellar tendinopathy.

  6. The temporal responses of protein synthesis, gene expression and cell signalling in human quadriceps muscle and patellar tendon to disuse

    PubMed Central

    de Boer, Maarten D; Selby, Anna; Atherton, Philip; Smith, Ken; Seynnes, Olivier R; Maganaris, Constantinos N; Maffulli, Nicola; Movin, Tomas; Narici, Marco V; Rennie, Michael J

    2007-01-01

    We hypothesized that rates of myofibrillar and patellar tendon collagen synthesis would fall over time during disuse, the changes being accompanied in muscle by decreases in focal adhesion kinase (FAK) phosphorylation and in gene expression for proteolytic enzymes. We studied nine men (22 ± 4 years, BMI 24 ± 3 kg m−2 (means ± s.d.) who underwent unilateral lower leg suspension for 23 days; five were studied between 0 and 10 days and four between 10 and 21 days. Muscle and tendon biopsies were taken in the postabsorptive state at days 0, 10 and 21 for measurement of protein synthesis, gene expression and protein phosphorylation. Muscle cross-sectional area decreased by 5.2% at 14 days and 10.0% (both P < 0.001), at 23 days, i.e. 0.5% day−1, whereas tendon dimensions were constant. Rates of myofibrillar protein synthesis fell (P < 0.01) from 0.047% h−1 at day 0 to 0.022% h−1 at 10 days without further changes. Tendon collagen synthetic rates also fell (P < 0.01), from 0.052 to 0.023% h−1 at 10 days and then to 0.010% h−1 at 21 days. FAK phosphorylation decreased 30% (P < 0.01) at 10 days. No changes occurred in the amounts/phosphorylation of PKB–P70s6k–mTOR pathway components. Expression of mRNA for MuRF-1 increased ∼3-fold at 10 days without changes in MAFbx or tripeptidyl peptidase II mRNA, but all decreased between 10 and 21 days. Thus, both myofibrillar and tendon protein synthetic rates show progressive decreases during 21 days of disuse; in muscle, this is accompanied by decreased phosphorylation of FAK, with no marked increases in genes for proteolytic enzymes. PMID:17901116

  7. Semiextended approach for intramedullary nailing via a patellar eversion technique for tibial-shaft fractures: Evaluation of the patellofemoral joint.

    PubMed

    Yasuda, Tomohiro; Obara, Shu; Hayashi, Junji; Arai, Masayuki; Sato, Kaoru

    2017-06-01

    Intramedullary nail fixation is a common treatment for tibial-shaft fractures, and it offers a better functional prognosis than other conservative treatments. Currently, the primary approach employed during intramedullary nail insertion is the semiextended position is the suprapatellar approach, which involves a vertical incision of the quadriceps tendon Damage to the patellofemoral joint cartilage has been highlighted as a drawback associated with this approach. To avoid this issue, we perform surgery using the patellar eversion technique and a soft sleeve. This method allows the articular surface to be monitored during intramedullary nail insertion. We arthroscopically assessed the effect of this technique on patellofemoral joint cartilage. The patellar eversion technique allows a direct view and protection of the patellofemoral joint without affecting the patella. Thus, damage to the patellofemoral joint cartilage can be avoided. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Moderate treadmill running exercise prior to tendon injury enhances wound healing in aging rats

    PubMed Central

    Zhang, Jianying; Yuan, Ting; Wang, James H-C.

    2016-01-01

    The effect of exercise on wound healing in aging tendon was tested using a rat moderate treadmill running (MTR) model. The rats were divided into an MTR group that ran on a treadmill for 4 weeks and a control group that remained in cages. After MTR, a window defect was created in the patellar tendons of all rats and wound healing was analyzed. We found that MTR accelerated wound healing by promoting quicker closure of wounds, improving the organization of collagen fibers, and decreasing senescent cells in the wounded tendons when compared to the cage control. MTR also lowered vascularization, increased the numbers of tendon stem/progenitor cells (TSCs) and TSC proliferation than the control. Besides, MTR significantly increased the expression of stem cell markers, OCT-4 and Nanog, and tenocyte genes, Collagen I, Collagen III and tenomodulin, and down-regulated PPAR-γ, Collagen II and Runx-2 (non-tenocyte genes). These findings indicated that moderate exercise enhances healing of injuries in aging tendons through TSC based mechanisms, through which exercise regulates beneficial effects in tendons. This study reveals that appropriate exercise may be used in clinics to enhance tendon healing in aging patients. PMID:26885754

  9. Moderate treadmill running exercise prior to tendon injury enhances wound healing in aging rats.

    PubMed

    Zhang, Jianying; Yuan, Ting; Wang, James H-C

    2016-02-23

    The effect of exercise on wound healing in aging tendon was tested using a rat moderate treadmill running (MTR) model. The rats were divided into an MTR group that ran on a treadmill for 4 weeks and a control group that remained in cages. After MTR, a window defect was created in the patellar tendons of all rats and wound healing was analyzed. We found that MTR accelerated wound healing by promoting quicker closure of wounds, improving the organization of collagen fibers, and decreasing senescent cells in the wounded tendons when compared to the cage control. MTR also lowered vascularization, increased the numbers of tendon stem/progenitor cells (TSCs) and TSC proliferation than the control. Besides, MTR significantly increased the expression of stem cell markers, OCT-4 and Nanog, and tenocyte genes, Collagen I, Collagen III and tenomodulin, and down-regulated PPAR-γ, Collagen II and Runx-2 (non-tenocyte genes). These findings indicated that moderate exercise enhances healing of injuries in aging tendons through TSC based mechanisms, through which exercise regulates beneficial effects in tendons. This study reveals that appropriate exercise may be used in clinics to enhance tendon healing in aging patients.

  10. Use of smartphones and portable media devices for quantifying human movement characteristics of gait, tendon reflex response, and Parkinson's disease hand tremor.

    PubMed

    LeMoyne, Robert; Mastroianni, Timothy

    2015-01-01

    Smartphones and portable media devices are both equipped with sensor components, such as accelerometers. A software application enables these devices to function as a robust wireless accelerometer platform. The recorded accelerometer waveform can be transmitted wireless as an e-mail attachment through connectivity to the Internet. The implication of such devices as a wireless accelerometer platform is the experimental and post-processing locations can be placed anywhere in the world. Gait was quantified by mounting a smartphone or portable media device proximal to the lateral malleolus of the ankle joint. Attributes of the gait cycle were quantified with a considerable accuracy and reliability. The patellar tendon reflex response was quantified by using the device in tandem with a potential energy impact pendulum to evoke the patellar tendon reflex. The acceleration waveform maximum acceleration feature of the reflex response displayed considerable accuracy and reliability. By mounting the smartphone or portable media device to the dorsum of the hand through a glove, Parkinson's disease hand tremor was quantified and contrasted with significance to a non-Parkinson's disease steady hand control. With the methods advocated in this chapter, any aspect of human movement may be quantified through smartphones or portable media devices and post-processed anywhere in the world. These wearable devices are anticipated to substantially impact the biomedical and healthcare industry.

  11. Treatment of Patellar Lower Pole Fracture with Modified Titanium Cable Tension Band Plus Patellar Tibial Tunnel Steel "8" Reduction Band.

    PubMed

    Li, Jiaming; Wang, Decheng; He, Zhiliang; Shi, Hao

    2018-01-08

    To determine the efficacy of modified titanium tension band plus patellar tendon tunnel steel 8 "reduction band" versus titanium cable tension band fixation for the treatment of patellar lower pole fracture. 58 patients with lower patella fracture were enrolled in this study, including 30 patients treated with modified titanium cable tension band plus patellar tibial tunnel wire "8" tension band internal fixation (modified group), and 28 patients with titanium cable tension band fixation. All patients were followed up for 9∼15 months with an average of 11.6 months. Knee flexion was significantly improved in the modified group than in the titanium cable tension band group (111.33 ± 13 degrees versus 98.21 ± 21.70 degrees, P = 0.004). The fracture healing time showed no significant difference. At the end of the follow-up, the improvement excellent rate was 93.33% in the modified group, and 82.14% in the titanium cable tension band group. Titanium cable tension band internal fixation loosening was found in 2 cases, including 1 case of treatment by two surgeries without loose internal fixation. The modified titanium cable tension band with "8" tension band fixation showed better efficacy for lower patella fractures than titanium cable tension band fixation.

  12. Position of the patella in adults in central India: evaluation of the Insall-Salvati ratio.

    PubMed

    Upadhyay, Sachin; Raza, H K T; Srivastava, Pranay

    2013-04-01

    To assess the Insall-Salvati ratio in normal Indian adults to determine its applicability and the incidence of patella alta and baja in Indian populations. 800 knees in 200 men and 200 women aged 18 to 50 (mean, 30) years were evaluated using lateral radiographs. The knee was set in semi-flexion (30º) to enable good visualisation of the patellar tendon and its insertion into the tibia on radiographs. The length of the patellar tendon (LT) over the length of the patella (LP)-the Insall-Salvati ratio-was measured, using a vernier caliper. The mean LT/LP ratio was 1.14 (standard deviation, 0.18). Based on the 95% confidence interval, the ratio was considered normal if within ±40%. The LT/LP ratio was significantly higher in females than males (1.17 vs. 1.12, p<0.01). The cut-off point of patella alta was significantly greater in our Indian subjects than in western subjects (>1.5 vs. >1.2, p<0.0001). In the present cohort, the frequencies of patella alta (ratio, >1.5) and patella baja (ratio, <0.7) were 2.8% and 1%, respectively. The use of the Insall-Salvati ratio to determine the patellar position is less applicable to Indian populations in which squatting, sitting cross-legged, and kneeling are customs. We propose that the normal range of the ratio for squatters among Indian populations be 0.7 to 1.5.

  13. INVESTIGATING THE EFFECTIVENESS OF KINESIO® TAPING SPACE CORRECTION METHOD IN HEALTHY ADULTS ON PATELLOFEMORAL JOINT AND SUBCUTANEOUS SPACE.

    PubMed

    Lyman, Katie J; Keister, Kassiann; Gange, Kara; Mellinger, Christopher D; Hanson, Thomas A

    2017-04-01

    Limited quantitative, physiological evidence exists regarding the effectiveness of Kinesio® Taping methods, particularly with respect to the potential ability to impact underlying physiological joint space and structures. To better understand the impact of these techniques, the underlying physiological processes must be investigated in addition to the examination of more subjective measures related to pain in unhealthy tissues. The purpose of this study was to determine whether the Kinesio® Taping Space Correction Method created a significant difference in patellofemoral joint space, as quantified by diagnostic ultrasound. Pre-test/post-test prospective cohort study. Thirty-two participants with bilaterally healthy knees and no past history of surgery took part in the study. For each participant, diagnostic ultrasound was utilized to collect three measurements: the patellofemoral joint space, the distance from the skin to the superficial patella, and distance from the skin to the patellar tendon. The Kinesio® Taping Space Correction Method was then applied. After a ten-minute waiting period in a non-weight bearing position, all three measurements were repeated. Each participant served as his or her own control. Paired t tests showed a statistically significant difference (mean difference = 1.1 mm, t [3,1]  = 2.823, p  = 0.008, g  = .465) between baseline and taped conditions in the space between the posterior surface of the patella to the medial femoral condyle. Neither the distance from the skin to the superficial patella nor the distance from the skin to the patellar tendon increased to a statistically significant degree. The application of the Kinesio® Taping Space Correction Method increases the patellofemoral joint space in healthy adults by increasing the distance between the patella and the medial femoral condyle, though it does not increase the distance from the skin to the superficial patella nor to the patellar tendon. 3.

  14. Patellar tendon vibration reduces the increased facilitation from quadriceps to soleus in post-stroke hemiparetic individuals.

    PubMed

    Maupas, Eric; Dyer, Joseph-Omer; Melo, Sibele de Andrade; Forget, Robert

    2017-09-01

    Stimulation of the femoral nerve in healthy people can facilitate soleus H-reflex and electromyography (EMG) activity. In stroke patients, such facilitation of transmission in spinal pathways linking the quadriceps and soleus muscles is enhanced and related to co-activation of knee and ankle extensors while sitting and walking. Soleus H-reflex facilitation can be depressed by vibration of the quadriceps in healthy people, but the effects of such vibration have never been studied on the abnormal soleus facilitation observed in people after stroke. To determine whether vibration of the quadriceps can modify the enhanced heteronymous facilitation of the soleus muscle observed in people with spastic stroke after femoral nerve stimulation and compare post-vibration effects on soleus facilitation in control and stroke individuals. Modulation of voluntary soleus EMG activity induced by femoral nerve stimulation (2×motor threshold) was assessed before, during and after vibration of the patellar tendon in 10 healthy controls and 17 stroke participants. Voluntary soleus EMG activity was facilitated by femoral nerve stimulation in 4/10 (40%) controls and 11/17 (65%) stroke participants. The level of facilitation was greater in the stroke than control group. Vibration significantly reduced early heteronymous facilitation in both groups (50% of pre-vibration values). However, the delay in recovery of soleus facilitation after vibration was shorter for the stroke than control group. The control condition with the vibrator turned off had no effect on the modulation. Patellar tendon vibration can reduce the facilitation between knee and ankle extensors, which suggests effective presynaptic inhibition but decreased post-activation depression in the lower limb of people after chronic hemiparetic stroke. Further studies are warranted to determine whether such vibration could be used to reduce the abnormal extension synergy of knee and ankle extensors in people after hemiparetic stroke. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  15. Autonomic Responses to Ultrasound-Guided Percutaneous Needle Electrolysis: Effect of Needle Puncture or Electrical Current?

    PubMed

    García Bermejo, Paula; De La Cruz Torres, Blanca; Naranjo Orellana, José; Albornoz Cabello, Manuel

    2018-01-01

    The aim of this study was to establish if the changes in sympathetic and parasympathetic activity (analyzed through heart-rate variability [HRV]) during ultrasound (US)-guided percutaneous needle electrolysis (PNE) is due to the effect of needle puncture only or of the PNE technique per se where the puncture and galvanic current are combined. This was an experimental, case-control study that took place at the University of Seville. Subjects were 36 male footballers who were randomly allocated to three groups: a control group (CG; 12 players), for whom HRV was recorded for 10 min, both at rest and during an exhaustive US examination of the patellar tendon and adjacent structures; a first experimental group (PNE group; 12 players), for whom HRV was recorded for 10 min, both at rest and during application of US-guided PNE in the patellar tendon; and a second experimental group (needle group; 12 players), for whom HRV was recorded for 10 min, both at rest and during application of US-guided PNE without electrical current in the patellar tendon. The outcome measures were the diameters of the Poincaré plot (SD1, SD2), stress score, and sympathetic/parasympathetic ratio. There were no differences between groups in any baseline measurements, nor were there any significant differences between CG measurements (baseline vs. intervention). The PNE group exhibited statistically significant increases in SD1 (p = 0.01) and SD2 (p = 0.004) and statistically significant decreases in SS and S/PS ratio (p = 0.03), indicating increased parasympathetic and decreased sympathetic activity, respectively. The needle group exhibited statistically significant increases in SD2 (p = 0.02) and statistically significant decreases in SS (p = 0.02), indicating decreased sympathetic activity. The application of the US-guided PNE technique caused a measurable increase in parasympathetic activity (detected by HRV), which was due to the combination of needle puncture and electric current.

  16. Effect of Intraoperative Platelet-Rich Plasma Treatment on Postoperative Donor Site Knee Pain in Patellar Tendon Autograft Anterior Cruciate Ligament Reconstruction: A Double-Blind Randomized Controlled Trial.

    PubMed

    Walters, Brian L; Porter, David A; Hobart, Sarah J; Bedford, Benjamin B; Hogan, Daniel E; McHugh, Malachy M; Klein, Devon A; Harousseau, Kendall; Nicholas, Stephen J

    2018-05-01

    Donor site morbidity in the form of anterior knee pain is a frequent complication after bone-patellar tendon-bone (BPTB) autograft anterior cruciate ligament (ACL) reconstruction. Hypothesis/Purpose: The purpose was to examine the effect of the intraoperative administration of platelet-rich plasma (PRP) on postoperative kneeling pain. It was hypothesized that PRP treatment would reduce knee pain. Randomized controlled trial; Level of evidence, 2. Fifty patients (mean ± SD age, 30 ± 12 years) undergoing BPTB ACL autograft reconstruction were randomized to the PRP (n = 27) or sham (n = 23) treatment. In either case, 10 mL of venous blood was drawn before the induction of anesthesia and either discarded (sham) or processed (PRP) for preparation of a PRP gel to be later mixed with donor site bone chips and inserted into the patellar defect. At 12 weeks, 6 months, 1 year, and 2 years after surgery, patients completed International Knee Documentation Committee (IKDC) forms and visual analog scale pain scores for activities of daily living and kneeling. Healing indices at the donor site were assessed by routine noncontrast magnetic resonance imaging (MRI) at 6 months. Mixed-model analysis of variance was used to assess the effect of PRP on patient symptoms and MRI indices of donor site healing, as measured by the width of the donor site defect. Kneeling pain, pain with activities of daily living, and IKDC scores were not different between treatment groups at any of the time intervals ( P = .08-.83). Kneeling pain improved from 12 weeks to 6 months and from 1 to 2 years ( P < .05). IKDC scores improved substantially from 12 weeks to 6 months ( P < .001) and continued to improve to 2 years (PRP, 86 ± 19; sham, 89 ± 10). MRI indices of donor site healing were not different between treatment groups ( P = .53-.90). Whether randomized to receive PRP in their patellar defect or not, patients continued to have similar levels of kneeling pain and patellar defect sizes after autograft BPTB ACL reconstruction. Registration: NCT01765712 ( ClinicalTrials.gov identifier).

  17. Low-frequency pulsed electromagnetic fields significantly improve time of closure and proliferation of human tendon fibroblasts

    PubMed Central

    2014-01-01

    Background The promotion of the healing process following musculoskeletal injuries comprises growth factor signalling, migration, proliferation and apoptosis of cells. If these processes could be modulated, the healing of tendon tissue may be markedly enhanced. Here, we report the use of the Somagen™ device, which is certified for medical use according to European laws. It generates low-frequency pulsed electromagnetic fields that trigger effects of a nature that are yet to be determined. Methods A 1.5-cm wide, linear scrape was introduced into patellar tendon fibroblast cultures (N = 5 donors). Treatment was carried out every second day. The regimen was applied three times in total with 30 minutes comprising pulsed electromagnetic field packages with two fundamental frequencies (10 minutes of 33 Hz, 20 minutes of 7.8 Hz). Control cells remained untreated. All samples were analyzed for gap closure time, proliferation and apoptosis one week after induction of the scrape wound. Results The mean time for bridging the gap in the nontreated cells was 5.05 ± 0.33 days, and in treated cells, it took 3.35 ± 0.38 days (P <0.001). For cell cultures with scrape wounds, a mean value for BrdU incorporation of OD = 0.70 ± 0.16 was found. Whereas low-frequency pulsed electromagnetic fields treated samples showed OD = 1.58 ± 0.24 (P <0.001). However, the percentage of apoptotic cells did not differ between the two groups. Conclusions Our data demonstrate that low-frequency pulsed electromagnetic fields emitted by the Somagen™ device influences the in vitro wound healing of patellar tendon fibroblasts and, therefore, possibly increases wound healing potential. PMID:24996421

  18. Sterilization with electron beam irradiation influences the biomechanical properties and the early remodeling of tendon allografts for reconstruction of the anterior cruciate ligament (ACL).

    PubMed

    Schmidt, Tanja; Hoburg, Arnd; Broziat, Christine; Smith, Mark D; Gohs, Uwe; Pruss, Axel; Scheffler, Sven

    2012-08-01

    Although allografts for anterior cruciate ligament (ACL) replacement have shown advantages compared to autografts, their use is limited due to the risk of disease transmission and the limitations of available sterilization methods. Gamma sterilization has shown detrimental effects on graft properties at the high doses required for sufficient pathogen inactivation. In our previous in vitro study on human patellar tendon allografts, Electron beam (Ebeam) irradiation showed less detrimental effects compared to gamma sterilization (Hoburg et al. in Am J Sports Med 38(6):1134-1140, 2010). To investigate the biological healing and restoration of the mechanical properties of a 34 kGy Ebeam treated tendon allograft twenty-four sheep underwent ACL replacement with either a 34 kGy Ebeam treated allograft or a non-sterilized fresh frozen allograft. Biomechanical testing of stiffness, ultimate failure load and AP-laxity as well as histological analysis to investigate cell, vessel and myofibroblast-density were performed after 6 and 12 weeks. Native sheep ACL and hamstring tendons (HAT, each n = 9) served as controls. The results of a previous study analyzing the remodeling of fresh frozen allografts (n = 12) and autografts (Auto, n = 18) with the same study design were also included in the analysis. Statistics were performed using Mann-Whitney U test followed by Bonferroni-Holm correction. Results showed significantly decreased biomechanical properties during the early remodeling period in Ebeam treated grafts and this was accompanied with an increased remodeling activity. There was no recovery of biomechanical function from 6 to 12 weeks in this group in contrast to the results observed in fresh frozen allografts and autografts. Therefore, high dose Ebeam irradiation investigated in this paper cannot be recommended for soft tissue allograft sterilization.

  19. Effectiveness of the Intratissue Percutaneous Electrolysis (EPI®) technique and isoinertial eccentric exercise in the treatment of patellar tendinopathy at two years follow-up.

    PubMed

    Abat, Ferran; Diesel, Wayne-J; Gelber, Pablo-E; Polidori, Fernando; Monllau, Joan-Carles; Sanchez-Ibañez, Jose-Manuel

    2014-04-01

    to show the effect of Intratissue Percutaneous Electrolysis (EPI®) combined with eccentric programme in the treatment of patellar tendinopathy. prospective study of 33 athlete-patients consecutively treated for insertional tendinopathy with Intratissue Percutaneous Electrolysis (EPI®) and followed for 2 years. Functional assessment was performed at the first visit, at three months and two years with the Tegner scale and VISA-P. an average improvement in the VISA-P of 35 points was obtained. The mean duration of treatment was 4.5 weeks. Some 78.8% of the patients returned to the same level of physical activity as before the injury by the end of treatment, reaching 100% at two years. intratissue percutaneous electrolysis (EPI®) combined with an eccentric-based rehab program offers excellent results in terms of the clinical and functional improvement of the patellar tendon with low morbidity in a short-term period. Therapy, level 4.

  20. Evaluation of patients presenting with knee pain: Part II. Differential diagnosis.

    PubMed

    Calmbach, Walter L; Hutchens, Mark

    2003-09-01

    Knee pain is a common presenting complaint with many possible causes. An awareness of certain patterns can help the family physician identify the underlying cause more efficiently. Teenage girls and young women are more likely to have patellar tracking problems such as patellar subluxation and patellofemoral pain syndrome, whereas teenage boys and young men are more likely to have knee extensor mechanism problems such as tibial apophysitis (Osgood-Schlatter lesion) and patellar tendonitis. Referred pain resulting from hip joint pathology, such as slipped capital femoral epiphysis, also may cause knee pain. Active patients are more likely to have acute ligamentous sprains and overuse injuries such as pes anserine bursitis and medial plica syndrome. Trauma may result in acute ligamentous rupture or fracture, leading to acute knee joint swelling and hemarthrosis. Septic arthritis may develop in patients of any age, but crystal-induced inflammatory arthropathy is more likely in adults. Osteoarthritis of the knee joint is common in older adults.

  1. Pseudo-Patella Baja after total knee arthroplasty

    PubMed Central

    Kazemi, Seyyed Morteza; Besheli, Laleh Daftari; Eajazi, Alireza; Sajadi, Mohammad Reza Miniator; Okhovatpoor, Mohammad Ali; Zanganeh, Ramin Farhang; Minaei, Reza

    2011-01-01

    Summary Background One of the complications of total knee arthroplasty (TKA) which has not yet been directly addressed is pseudo-patella baja (PPB). True patella baja (PB) is present when the length of the patellar tendon becomes shorter. PPB is present when the patella tendon is not shortened, but the level of the joint line is elevated. This study was conducted to assess PPB in TKA. Material/Methods Sixty patients who had had a primary TKA at our center between 1995 and 2005 were included. The average follow-up was 27.5 months. The Knee Society Scoring (KSS), lateral knee x-rays and the Blackburne-Peel index were used for assessments. Results Out of the 60 patients, 43 (72%) demonstrated no joint line elevation or patellar tendon shortening (group A). Fifteen patients (25%) had joint line elevation (group B), and both PB and PPB were present in 2 (3%) patients (group C). KSS was lower in groups B and C compared with group A, but this difference was not statistically significant. The average range of motion (ROM) in group A was significantly higher compared with either group B or C, and patients in groups B and C showed significantly more severe pain compared with group A (P<0.001). Conclusions PPB is not an uncommon finding after TKA and is associated with a statistically significant decrease in ROM and an increase in pain. Furthermore, KSS in the PPB group was less than in patients without PPB, although the difference was not statistically meaningful. PMID:21525812

  2. The Value of Visa-Score and Colour Flow Imaging in the Follow-Up of Non-Athletes Operated for Jumpers Knee.

    PubMed

    Salvesen, Eirik S; Holen, Ketil J

    2016-12-01

    The objective of this study was to assess if the Victorian Institute of Sport Assessment (VISA) questionnaire was suitable in the evaluation of patients from a mixed population with normal levels of sports activity, and if neovascularization of the patellar tendon demonstrated by color flow imaging (CFI) was more frequent in patients with lasting symptoms after surgical treatment for jumpers knee (JK). This study was conducted at St. Olavs Hospital, University Hospital of Trondheim, Norway, and included 21 men and 18 women who were operated for JK. Symptoms were assessed using the Knee Injury and Osteoarthritis Outcome Score (KOOS) and VISA questionnaires. Clinical and ultrasonographic examinations of the knees, including CFI, were done at a mean follow-up duration of 82 (range, 16-136) months after surgery. Patients with positive CFI also had significantly lower KOOS scores, whereas the total VISA-P (Victorian Institute of Sport Assessment - Patella) score showed no association. Patients with a positive clinical examination had significantly more frequent positive CFI findings than did patients with negative examinations. The operated patellar tendon was significantly thicker and had more frequent hypoechoic signal in the proximal part than the contralateral unoperated tendon. The post-operative VISA-P score seems less valuable in the evaluation of patients from a mixed population with normal levels of sports activity. CFI may be a valuable diagnostic tool in the evaluation of patients operated for JK.

  3. Conservative management of tendinopathy: an evidence-based approach

    PubMed Central

    Loppini, Mattia; Maffulli, Nicola

    2011-01-01

    Summary Tendinopathy is one of the most frequent overuse injuries associated with sport. It is a failure of a chronic healing response associated with both chronic overloaded and unloaded states. Although several conservative therapeutic options have been proposed, very few of them are supported by randomized controlled trials. Eccentric exercises provide excellent clinical results both in athletic and sedentary patients, with no reported adverse effects. Combining eccentric loading and low-energy shock wave therapy produces higher success rates compared with eccentric training alone or shock wave therapy alone. High-volume injection of normal saline solution, corticosteroids, or anesthetics can reduce pain and improve long-term function in patients with Achilles or patellar tendinopathy. The use of injectable substances such as platelet-rich plasma, autologous blood, polidocanol, and corticosteroids in and around tendons is not support by strong clinical evidence. Further randomized controlled trials are necessary to define the best conservative management of tendinopathy. PMID:23738261

  4. Deep and superficial infrapatellar bursae: cadaveric investigation of regional anatomy using magnetic resonance after ultrasound-guided bursography.

    PubMed

    Viegas, Flavio C; Aguiar, Rodrigo O C; Gasparetto, Emerson; Marchiori, Edson; Trudell, Debbie J; Haghighi, Parviz; Resnick, Donald

    2007-01-01

    To demonstrate the anatomy of the deep and superficial infrapatellar bursae using magnetic resonance (MR) imaging and anatomic correlation in cadavers. MR imaging of the infrapatellar bursae of nine cadaveric knees was performed after ultrasound-guided bursography. The images were compared with those seen on anatomic sectioning. Histologic analysis was obtained in two specimens. The deep infrapatellar bursa (DIB) was visualized in all specimens (n=9) and the superficial infrapatellar bursa (SIB) in five specimens (55%). The mean dimensions of the DIB in the craniocaudal, mediolateral, and anteroposterior planes were respectively 25, 28.7, and 6 mm, and for SIB 19.5, 21.2 and 2.2 mm. A fat apron dividing the DIB was depicted in eight knees (89%). Lateral extension of the DIB beyond the patellar tendon was observed in 100% of cases. Cadaveric analysis depicted a thin septum in the SIB in four of five cases (80%). The DIB is generally present and extends beyond the lateral margin of the patellar tendon. A fat apron partially separating this structure is usual. The SIB is not an unusual finding and may have a septum separating its compartments.

  5. Allogeneic versus autologous derived cell sources for use in engineered bone-ligament-bone grafts in sheep anterior cruciate ligament repair.

    PubMed

    Mahalingam, Vasudevan D; Behbahani-Nejad, Nilofar; Horine, Storm V; Olsen, Tyler J; Smietana, Michael J; Wojtys, Edward M; Wellik, Deneen M; Arruda, Ellen M; Larkin, Lisa M

    2015-03-01

    The use of autografts versus allografts for anterior cruciate ligament (ACL) reconstruction is controversial. The current popular options for ACL reconstruction are patellar tendon or hamstring autografts, yet advances in allograft technologies have made allogeneic grafts a favorable option for repair tissue. Despite this, the mismatched biomechanical properties and risk of osteoarthritis resulting from the current graft technologies have prompted the investigation of new tissue sources for ACL reconstruction. Previous work by our lab has demonstrated that tissue-engineered bone-ligament-bone (BLB) constructs generated from an allogeneic cell source develop structural and functional properties similar to those of native ACL and vascular and neural structures that exceed those of autologous patellar tendon grafts. In this study, we investigated the effectiveness of our tissue-engineered ligament constructs fabricated from autologous versus allogeneic cell sources. Our preliminary results demonstrate that 6 months postimplantation, our tissue-engineered auto- and allogeneic BLB grafts show similar histological and mechanical outcomes indicating that the autologous grafts are a viable option for ACL reconstruction. These data indicate that our tissue-engineered autologous ligament graft could be used in clinical situations where immune rejection and disease transmission may preclude allograft use.

  6. Biomechanical Effects of Posterior Condylar Offset and Posterior Tibial Slope on Quadriceps Force and Joint Contact Forces in Posterior-Stabilized Total Knee Arthroplasty.

    PubMed

    Kang, Kyoung-Tak; Koh, Yong-Gon; Son, Juhyun; Kwon, Oh-Ryong; Lee, Jun-Sang; Kwon, Sae Kwang

    2017-01-01

    This study aimed to determine the biomechanical effect of the posterior condylar offset (PCO) and posterior tibial slope (PTS) in posterior-stabilized (PS) fixed-bearing total knee arthroplasty (TKA). We developed ±1, ±2, and ±3 mm PCO models in the posterior direction and -3°, 0°, 3°, and 6° PTS models using a previously validated FE model. The influence of changes in the PCO and PTS on the biomechanical effects under deep-knee-bend loading was investigated. The contact stress on the PE insert increased by 14% and decreased by 7% on average as the PCO increased and decreased, respectively, compared to the neutral position. In addition, the contact stress on post in PE insert increased by 18% on average as PTS increased from -3° to 6°. However, the contact stress on the patellar button decreased by 11% on average as PTS increased from -3° to 6° in all different PCO cases. The quadriceps force decreased by 14% as PTS increased from -3° to 6° in all PCO models. The same trend was found in patellar tendon force. Changes in PCO had adverse biomechanical effects whereas PTS increase had positive biomechanical effects. However, excessive PTS should be avoided to prevent knee instability and subsequent failure.

  7. Implementation of a smartphone as a wireless gyroscope application for the quantification of reflex response.

    PubMed

    LeMoyne, Robert; Mastroianni, Timothy

    2014-01-01

    The patellar tendon reflex constitutes a fundamental aspect of the conventional neurological evaluation. Dysfunctional characteristics of the reflex response can augment the diagnostic acuity of a clinician for subsequent referral to more advanced medical resources. The capacity to quantify the reflex response while alleviating the growing strain on specialized medical resources is a topic of interest. The quantification of the tendon reflex response has been successfully demonstrated with considerable accuracy and consistency through using a potential energy impact pendulum attached to a reflex hammer for evoking the tendon reflex with a smartphone, such as an iPhone, application representing a wireless accelerometer platform to quantify reflex response. Another sensor integrated into the smartphone, such as an iPhone, is the gyroscope, which measures rate of angular rotation. A smartphone application enables wireless transmission through Internet connectivity of the gyroscope signal recording of the reflex response as an email attachment. The smartphone wireless gyroscope application demonstrates considerable accuracy and consistency for the quantification of the tendon reflex response.

  8. Biomechanical comparison between the rectangular-tunnel and the round-tunnel anterior cruciate ligament reconstruction procedures with a bone-patellar tendon-bone graft.

    PubMed

    Suzuki, Tomoyuki; Shino, Konsei; Otsubo, Hidenori; Suzuki, Daisuke; Mae, Tatsuo; Fujimiya, Mineko; Yamashita, Toshihiko; Fujie, Hiromichi

    2014-10-01

    The purpose of this study was to evaluate the effectiveness of 2 anterior cruciate ligament (ACL) reconstruction techniques using a bone-patellar tendon-bone (BPTB) graft with femoral tunnel, either a rectangular tunnel (RET) or a round tunnel (ROT). For experiment 1, nine fresh-frozen human cadaveric knees were tested with a robotic/universal force-moment sensor system to determine the initial optimal tension: the amount of graft tension at 15° of flexion most closely resembling the anterior laxity of a normal knee. The value was estimated by repeatedly measuring anterior laxity when 100 N of anteroposterior drawer load was applied to the knees at 30° of flexion after RET ACL or ROT ACL reconstruction. For experiment 2, six fresh-frozen human cadaveric knees were selected. On the basis of the initial tension determined in experiment 1, RET ACL reconstruction was conducted with the graft tensioned to 10 N, followed by ROT ACL reconstruction on the same knee at 40 N of initial tension, and the biomechanical efficacy of the 2 methods was compared. For experiment 1, the mean laxity match tension at 15° of flexion was 8.6 ± 4.8 N and 34.8 ± 9.2 N for RET- and ROT-reconstructed knees, respectively. For experiment 2, both RET and ROT ACL reconstructions were successful in controlling anterior tibial translation under anterior tibial loads, with the graft initially tensioned to 10 N in the former and to 40 N in the latter. However, the greater tensioning in ROT reconstruction led to proximal, posterior, and lateral displacement of the tibia along with its external and valgus rotation. The RET ACL-reconstructed knee more closely resembled the normal knee in biomechanical behavior. Although ROT reconstruction successfully controlled anterior translation with greater initial tensioning to the graft, the normal positional relation between the tibia and femur was impaired. Rectangular femoral ACL fixation constructs and grafts may prove more efficacious at restoring in vivo ACL kinematics than round femoral tunnels. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  9. Tendon Reattachment to Bone in an Ovine Tendon Defect Model of Retraction Using Allogenic and Xenogenic Demineralised Bone Matrix Incorporated with Mesenchymal Stem Cells.

    PubMed

    Thangarajah, Tanujan; Shahbazi, Shirin; Pendegrass, Catherine J; Lambert, Simon; Alexander, Susan; Blunn, Gordon W

    2016-01-01

    Tendon-bone healing following rotator cuff repairs is mainly impaired by poor tissue quality. Demineralised bone matrix promotes healing of the tendon-bone interface but its role in the treatment of tendon tears with retraction has not been investigated. We hypothesized that cortical demineralised bone matrix used with minimally manipulated mesenchymal stem cells will result in improved function and restoration of the tendon-bone interface with no difference between xenogenic and allogenic scaffolds. In an ovine model, the patellar tendon was detached from the tibial tuberosity and a complete distal tendon transverse defect measuring 1 cm was created. Suture anchors were used to reattach the tendon and xenogenic demineralised bone matrix + minimally manipulated mesenchymal stem cells (n = 5), or allogenic demineralised bone matrix + minimally manipulated mesenchymal stem cells (n = 5) were used to bridge the defect. Graft incorporation into the tendon and its effect on regeneration of the enthesis was assessed using histomorphometry. Force plate analysis was used to assess functional recovery. Compared to the xenograft, the allograft was associated with significantly higher functional weight bearing at 6 (P = 0.047), 9 (P = 0.028), and 12 weeks (P = 0.009). In the allogenic group this was accompanied by greater remodeling of the demineralised bone matrix into tendon-like tissue in the region of the defect (p = 0.015), and a more direct type of enthesis characterized by significantly more fibrocartilage (p = 0.039). No failures of tendon-bone healing were noted in either group. Demineralised bone matrix used with minimally manipulated mesenchymal stem cells promotes healing of the tendon-bone interface in an ovine model of acute tendon retraction, with superior mechanical and histological results associated with use of an allograft.

  10. The Role of Mechanical Loading in Tendon Development, Maintenance, Injury, and Repair

    PubMed Central

    Galloway, Marc T.; Lalley, Andrea L.; Shearn, Jason T.

    2013-01-01

    ➤ Tendon injuries often result from excessive or insufficient mechanical loading, impairing the ability of the local tendon cell population to maintain normal tendon function. ➤ The resident cell population composing tendon tissue is mechanosensitive, given that the cells are able to alter the extracellular matrix in response to modifications of the local loading environment. ➤ Natural tendon healing is insufficient, characterized by improper collagen fibril diameter formation, collagen fibril distribution, and overall fibril misalignment. ➤ Current tendon repair rehabilitation protocols focus on implementing early, well-controlled eccentric loading exercises to improve repair outcome. ➤ Tissue engineers look toward incorporating mechanical loading regimens to precondition cell populations for the creation of improved biological augmentations for tendon repair. PMID:24005204

  11. Spontaneous tendon rupture in systemic lupus erythematosus: association with Jaccoud's arthropathy.

    PubMed

    Alves, E M; Macieira, J C; Borba, E; Chiuchetta, F A; Santiago, M B

    2010-03-01

    Tendon rupture has rarely been described in patients with systemic lupus erythematosus. From observation of three cases of Jaccoud's arthropathy with tendon rupture, and considering that this arthropathy is more related to an inflammatory process of the tendon sheath than to synovitis per se, the intention of this study was to review the cases of tendon rupture in patients with systemic lupus erythematosus, in the hope of determining the frequency of Jaccoud's arthropathy associated with this complication. Systematic review using MEDLINE, Scielo and LILACS databases (1966 to 2009) and the following keywords: systemic lupus erythematosus, tendon rupture, Jaccoud's arthropathy. Secondary references were additionally obtained. Additionally, three Brazilian systemic lupus erythematosus patients who developed tendon rupture are described. Only 40 articles obtained fulfilled the previously established criteria. They were all case reports; the number of cases reported was 52 which, together with the three cases presented herein add up to 55 cases. Forty-six patients were women aged between 19 and 71 years, with a mean age of 40.1 +/- 12.4 years, and the average duration of the disease was 10 years. The most frequently observed rupture sites were the patellar and Achilles' tendons. While almost all patients described were on various doses of corticosteroids, 16 patients concomitantly had Jaccoud's arthropathy (29%). In conclusion, the association between Jaccoud's arthropathy and tendon rupture in systemic lupus erythematosus has been underestimated. As almost one-third of the systemic lupus erythematosus patients with tendon rupture also have Jaccoud's arthropathy, this arthropathy may be recognized as risk marker for tendon rupture.

  12. Shear load transfer in high and low stress tendons.

    PubMed

    Kondratko-Mittnacht, Jaclyn; Duenwald-Kuehl, Sarah; Lakes, Roderic; Vanderby, Ray

    2015-05-01

    Tendon is an integral part of joint movement and stability, as it functions to transmit load from muscle to bone. It has an anisotropic, fibrous hierarchical structure that is generally loaded in the direction of its fibers/fascicles. Internal load distributions are altered when joint motion rotates an insertion site or when local damage disrupts fibers/fascicles, potentially causing inter-fiber (or inter-fascicular) shear. Tendons with different microstructures (helical versus linear) may redistribute loads differently. This study explored how shear redistributes axial loads in rat tail tendon (low stress tendons with linear microstructure) and porcine flexor tendon (high stress with helical microstructure) by creating lacerations on opposite sides of the tendon, ranging from about 20% to 60% of the tendon width, to create various magnitudes of shear. Differences in fascicular orientation were quantified using polarized light microscopy. Unexpectedly, both tendon types maintained about 20% of pre-laceration stress values after overlapping cuts of 60% of tendon width (no intact fibers end to end) suggesting that shear stress transfer can contribute more to overall tendon strength and stiffness than previously reported. All structural parameters for both tendon types decreased linearly with increasing laceration depth. The tail tendon had a more rapid decline in post-laceration elastic stress and modulus parameters as well as a more linear and less tightly packed fascicular structure, suggesting that positional tendons may be less well suited to redistribute loads via a shear mechanism. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Shear Load Transfer in High and Low Stress Tendons

    PubMed Central

    Kondratko-Mittnacht, Jaclyn; Duenwald-Kuehl, Sarah; Lakes, Roderic; Vanderby, Ray

    2016-01-01

    Background Tendon is an integral part of joint movement and stability, as it functions to transmit load from muscle to bone. It has an anisotropic, fibrous hierarchical structure that is generally loaded in the direction of its fibers/fascicles. Internal load distributions are altered when joint motion rotates an insertion site or when local damage disrupts fibers/fascicles, potentially causing inter-fiber (or inter-fascicular) shear. Tendons with different microstructure (helical versus linear) may redistribute loads differently. Method of Approach This study explored how shear redistributes axial loads in rat tail tendon (low stress tendons with linear microstructure) and porcine flexor tendon (high stress with helical microstructure) by creating lacerations on opposite sides of the tendon, ranging from about 20-60% of the tendon width, to create various magnitudes of shear. Differences in fascicular orientation were quantified using polarized light microscopy. Results and Conclusions Unexpectedly, both tendon types maintained about 20% of pre-laceration stress values after overlapping cuts of 60% of tendon width (no intact fibers end to end) suggesting that shear stress transfer can contribute more to overall tendon strength and stiffness than previously reported. All structural parameters for both tendon types decreased linearly with increasing laceration depth. The tail tendon had a more rapid decline in post-laceration elastic stress and modulus parameters as well as a more linear and less tightly packed fascicular structure, suggesting that positional tendons may be less well suited to redistribute loads via a shear mechanism. PMID:25700261

  14. Tendon biomechanics and mechanobiology - a mini-review of basic concepts and recent advancements

    PubMed Central

    Wang, James H-C.; Guo, Qianping; Li, Bin

    2011-01-01

    Due to their unique hierarchical structure and composition, tendons possess characteristic biomechanical properties, including high mechanical strength and viscoelasticity, which enable them to carry and transmit mechanical loads (muscular forces) effectively. Tendons are also mechano-responsive by adaptively changing their structure and function in response to altered mechanical loading conditions. In general, mechanical loading at physiological levels is beneficial to tendons, but excessive loading or disuse of tendons is detrimental. This mechano-adaptability is due to the cells present in tendons. Tendon fibroblasts (tenocytes) are the dominant tendon cells responsible for tendon homeostasis and repair. Tendon stem cells (TSCs), which were recently discovered, also play a vital role in tendon maintenance and repair by virtue of their ability to self-renew and differentiate into tenocytes. TSCs may also be responsible for chronic tendon injury, or tendinopathy, by undergoing aberrant differentiation into non-tenocytes in response to excessive mechanical loading. Thus, it is necessary to devise optimal rehabilitation protocols in order to enhance tendon healing while reducing scar tissue formation and tendon adhesions. Moreover, along with scaffolds that can mimic tendon matrix environments and platelet-rich plasma (PRP), which serves as a source of growth factors, TSCs may be the optimal cell type for enhancing repair of injured tendons. PMID:21925835

  15. Tendon biomechanics and mechanobiology--a minireview of basic concepts and recent advancements.

    PubMed

    Wang, James H-C; Guo, Qianping; Li, Bin

    2012-01-01

    Due to their unique hierarchical structure and composition, tendons possess characteristic biomechanical properties, including high mechanical strength and viscoelasticity, which enable them to carry and transmit mechanical loads (muscular forces) effectively. Tendons are also mechanoresponsive by adaptively changing their structure and function in response to altered mechanical loading conditions. In general, mechanical loading at physiological levels is beneficial to tendons, but excessive loading or disuse of tendons is detrimental. This mechanoadaptability is due to the cells present in tendons. Tendon fibroblasts (tenocytes) are the dominant tendon cells responsible for tendon homeostasis and repair. Tendon stem cells (TSCs), which were recently discovered, also play a vital role in tendon maintenance and repair by virtue of their ability to self-renew and differentiate into tenocytes. TSCs may also be responsible for chronic tendon injury, or tendinopathy, by undergoing aberrant differentiation into nontenocytes in response to excessive mechanical loading. Thus, it is necessary to devise optimal rehabilitation protocols to enhance tendon healing while reducing scar tissue formation and tendon adhesions. Moreover, along with scaffolds that can mimic tendon matrix environments and platelet-rich plasma, which serves as a source of growth factors, TSCs may be the optimal cell type for enhancing repair of injured tendons. Copyright © 2012 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  16. Dynamic load indicators for take-off-landing sequence in blocks and attacks of elite female volleyball players.

    PubMed

    Kabaciński, Jarosław; Dworak, Lechosław Bogdan; Murawa, Michał; Rzepnicka, Agata

    2016-01-01

    Dynamic loads during landings determined by the ground reaction forces (GRFs) may elaborate internal loads and increase the risk of overload knee injuries as a result of performing volleyball jumps many times. The study dealt with a biomechanical assessment of dynamic load indicators in female volleyball players for the motion sequence of take-off-landing in blocks and attacks. Twelve professional female volleyball players participated in the study. Blocks and attacks were filmed by two cameras. GRFs vs. time graphs were recorded with the use of a force platform. Values of dynamic load indicators in terms of the relations of peak of vertical component of GRF, build-up index of this force (BIF), and power output (P) during landing to the vGRF, BIF and P during take-off (L/T) were calculated. The statistically significant ( p < 0.05) highest values of L/T indicators were found for back row attack spikes: 2.4 (vGRF), 12.2 (BIF) and 3.1 (P). In the case of blocks, slide attack spikes and attack line spikes, results of these variables were in range: 1.8÷2.1, 5.9÷7.6 and 2.1÷2.9, respectively. The reduction of GRFs during landings contributes to decreasing the level of the load indicators L/T which should minimize the incidence of anterior cruciate ligament and patellar tendon injuries in female volleyball players.

  17. Arthroscopic single-bundle anterior cruciate ligament reconstruction with six-strand hamstring tendon allograft versus bone-patellar tendon-bone allograft.

    PubMed

    Dai, Chengliang; Wang, Fei; Wang, Xiaomeng; Wang, Ruipeng; Wang, Shengjie; Tang, Shiyu

    2016-09-01

    The aim of this study was to compare the clinical outcomes of arthroscopic single-bundle anterior cruciate ligament (ACL) reconstruction with six-strand hamstring tendon (HT) allograft versus bone-patellar tendon-bone (BPTB) allograft. The prospective randomized controlled trial was included 129 patients. Sixty-nine patients received reconstruction with six-strand HT allografts (HT group), whereas 60 patients with BPTB allografts (BPTB group). Outcome assessment included re-rupture findings, International Knee Documentation Committee (IKDC) scores, Lysholm scores, KT-1000 arthrometer, Lachman test, pivot-shift test, range of motion (ROM) and single-leg hop test. At a mean follow-up of 52 months, 113 patients (HT group, 61 patients; BPTB group, 52 patients) completed a minimum 4-year follow-up. Four patients in HT group and six in BPTB group experienced ACL re-rupture (6.2 vs. 10.3 %) and received revision surgery. Significant between-group differences were observed in KT-1000 outcomes and pivot-shift test 1 (1.2 ± 1.5 vs. 1.8 ± 1.3, p = 0.025; positive rate 6.5 vs. 18.9 %, p = 0.036), 2 (1.1 ± 1.4 vs. 1.6 ± 1.2, p = 0.044; 8.1 vs. 20.7 %, p = 0.039), 4 (1.1 ± 1.5 vs. 1.7 ± 1.4, p = 0.031; 9.7 vs. 25 %, p = 0.012) years postoperatively. The outcomes between the two groups were comparable in terms of IKDC scores, Lysholm scores, Lachman test, ROM and single-leg hop test. Six-strand HT allograft achieved superior anteroposterior and rotational stability after single-bundle ACL reconstruction. It is a reasonable graft substitute for ACL reconstruction. II.

  18. Anatomic single-bundle anterior cruciate ligament reconstruction improves walking economy: hamstrings tendon versus patellar tendon grafts.

    PubMed

    Iliopoulos, Efthymios; Galanis, Nikiforos; Zafeiridis, Andreas; Iosifidis, Michael; Papadopoulos, Pericles; Potoupnis, Michael; Geladas, Nikolaos; Vrabas, Ioannis S; Kirkos, John

    2017-10-01

    Anterior cruciate ligament (ACL) injury is associated with a pathologic gait pattern and increased energy cost during locomotion. ACL reconstruction could improve the gait pattern. Hamstrings tendon (HAM) and bone-patellar tendon-bone (BPTB) grafts are usually used for reconstruction. The aim of this study was to compare the efficacy of anatomic ACL reconstruction with HAM and BPTB grafts on improving and normalizing the energy cost and physiologic reserves during flat, uphill, and downhill walking. Twenty male subjects with unilateral ACL injuries were randomly assigned to ACL reconstruction with a HAM (n = 10) or BPTB (n = 10) graft. Ten matched controls were also enrolled. All participants performed three 8-min walking tasks at 0, +10, and -10 % gradients before and 9 months after surgery. Energy cost (oxygen consumption, VO 2 ), heart rate (HR), and ventilation (VE) were measured. Lysholm/IKDC scores were recorded. Pre-operatively, VO 2 , HR, and VE were higher in the HAM and BPTB groups than in controls during walking at 0, +10, and -10 % gradients (p < 0.001-0.01). Post-operatively, both HAM and BPTB groups showed reduced VO 2 , HR, and VE during the three walking tasks (p < 0.001-0.01). Although the post-operative VO 2 in both surgical groups reached 90-95 % of the normative (control) value during walking, it remained elevated against the value observed in controls (p < 0.001-0.01). The HAM and BPTB groups showed no differences in post-surgical VO 2 or HR during walking at all three gradients. Anatomic ACL reconstruction with either HAM or BPTB graft resulted in similar short-term improvements in energy cost and nearly normalized locomotion economy and cardiorespiratory reserves during flat, uphill, and downhill walking. The improved locomotion economy is an additional benefit of anatomic ACL reconstruction, irrespective of the type of graft used, that the orthopaedic surgeons should consider. II.

  19. Study protocol: a double blind randomised control trial of high volume image guided injections in Achilles and patellar tendinopathy in a young active population.

    PubMed

    Barker-Davies, Robert M; Nicol, Alastair; McCurdie, I; Watson, James; Baker, Polly; Wheeler, Patrick; Fong, Daniel; Lewis, Mark; Bennett, Alexander N

    2017-05-22

    Chronic tendinopathy is a significant problem particularly in active populations limiting sporting and occupational performance. The prevalence of patellar tendinopathy in some sports is near 50% and the incidence of lower limb tendinopathy is 1.4% p.a. in the UK Military. Management includes isometric, eccentric, heavy slow resistance exercises and extracorporeal shockwave therapy (ESWT). Often these treatments are inadequate yet there is no good evidence for injection therapies and success rates from surgery can be as low as 50%. High Volume Image Guided Injection (HVIGI) proposes to strip away the neovascularity and disrupt the nerve ingrowth seen in chronic cases and has shown promising results in case series. This study aims to investigate the efficacy of HVIGI in a randomised controlled trial (RCT). RCT comparing 40ml HVIGI, with or without corticosteroid, with a 3ml local anaesthetic sham-control injection. Ninety-six participants will be recruited. male, 18-55 years old, chronic Achilles or patellar tendinopathy of at least 6 months, failed conservative management including ESWT, and Ultrasound (US) evidence of neovascularisation, tendon thickening and echogenic changes. Outcome measures will be recorded at baseline, 6 weeks, 3, 6 and 12 months. Primary outcome measures include The Victoria Institute of Sport Assessments for Achilles and patellar tendinopathy (VISA-A and VISA-P) and VAS pain. Secondary outcome measures include Modified Ohberg score, maximum tendon diameter and assessment of hypoechoic appearance on US, and Functional Activity Assessment. Despite previous interventional trials and reviews there is still insufficient evidence to guide injectable therapy for chronic tendinopathy that has failed conservative treatment. The scant evidence available suggests HVIGI has the greatest potential however there is no level one RCT evidence to support this. Investigating the efficacy of HVIGI against control in a RCT and separating the effect of HVIGI and corticosteroid will add high level evidence to the management of chronic tendinopathy resistant to conservative treatment. EudraCT: 2015-003587-36 3 Dec 2015.

  20. Shear Wave Elastography (SWE) for Monitoring of Treatment of Tendinopathies: A Double-blinded, Longitudinal Clinical Study.

    PubMed

    Dirrichs, Timm; Quack, Valentin; Gatz, Matthias; Tingart, Markus; Rath, Björn; Betsch, Marcel; Kuhl, Christiane K; Schrading, Simone

    2018-03-01

    We aimed to investigate the diagnostic accuracy with which shear wave elastography (SWE) can be used to monitor response to treatment of tendinopathies, and to compare it to conventional ultrasound (US)-imaging methods (B-mode US (B-US) and power Doppler US (PD-US)). A prospective Institutional Review Board-approved longitudinal study on 35 patients with 47 symptomatic tendons (17 Achilles-, 15 patellar-, and 15 humeral-epicondylar) who underwent standardized multimodal US and standardized clinical assessment before and after 6 months of treatment (tailored stretching exercise, sport break, and local Polidocanol) was carried out. All US studies were performed by radiologists blinded to the clinical symptoms on both tendon sides to avoid biased interpretations, by B-US, PD-US, and SWE, conducted in the same order, using a high-resolution linear 15 MHz probe (Aixplorer). Orthopedic surgeons who were in turn blinded to US imaging results used established orthopedic scores (Victorian Institute of Sports Assessment questionnaire for Achilles, Victorian Institute of Sports Assessment questionnaire for patellar tendons, and Disability Arm Shoulder Hand scoring system) to rate presence, degree, and possible resolution of symptoms. We analyzed the diagnostic accuracy with which the different US imaging methods were able to detect symptomatic tendons at baseline as well as treatment effects, with orthopedic scores serving as reference standard. B-US, PD-US, and SWE detected symptomatic tendons with a sensitivity of 66% (31 of 47), 72% (34 of 47), and 87.5% (41 of 47), respectively. Positive predictive value was 0.67 for B-US, 0.87 for PD-US, and 1 for SWE. After treatment, clinical scores improved in 68% (32 of 47) of tendons. Treatment effects were observable by B-US, PD-US, and SWE with a sensitivity of 3.1% (1 of 32), 28.1% (9 of 32), and 81.3% (26 of 32), respectively. B-US was false-positive in 68.8% (20 of 32), PD-US in 46.9% (15 of 32), and SWE in 12.5% (4 of 32) (SWE). Clinical scores and B-US, PD-US, and SWE findings correlated poorly (r = 0.24), moderately (r = 0.59), and strongly (r = 0.80). Unlike B-US or PD-US, SWE is able to depict processes associated with tendon healing and may be a useful tool to monitor treatment effects. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  1. Nandrolone decanoate and load increase remodeling and strength in human supraspinatus bioartificial tendons.

    PubMed

    Triantafillopoulos, Ioannis K; Banes, Albert J; Bowman, Karl F; Maloney, Melissa; Garrett, William E; Karas, Spero G

    2004-06-01

    To date, no studies document the effect of anabolic steroids on rotator cuff tendons. Controlled laboratory study. Anabolic steroids enhance remodeling and improve the biomechanical properties of bioartificially engineered human supraspinatus tendons. Bioartificial tendons were treated with either nandrolone decanoate (nonload, steroid, n = 18), loading (load, nonsteroid, n = 18), or both (load, steroid, n = 18). A control group received no treatment (nonload, nonsteroid [NLNS], n = 18). Bioartificial tendons' remodeling was assessed by daily scanning, cytoskeletal organization by staining, matrix metalloproteinase-3 levels by ELISA assay, and biomechanical properties by load-to-failure testing. The load, steroid group showed the greatest remodeling and the best organized actin cytoskeleton. Matrix metallo-proteinase-3 levels in the load, steroid group were greater than those of the nonload, nonsteroid group (P <.05). Ultimate stress and ultimate strain in the load, steroid group were greater than those of the nonload, nonsteroid and nonload, steroid groups (P <.05). The strain energy density in the load, steroid group was greater when compared to other groups (P <.05). Nandrolone decanoate and load acted synergistically to increase matrix remodeling and biomechanical properties of bioartificial tendons. Data suggest anabolic steroids may enhance production of bioartificial tendons and rotator cuff tendon healing in vitro. More research is necessary before such clinical use is recommended.

  2. The TOPSHOCK study: Effectiveness of radial shockwave therapy compared to focused shockwave therapy for treating patellar tendinopath - design of a randomised controlled trial

    PubMed Central

    2011-01-01

    Background Patellar tendinopathy is a chronic overuse injury of the patellar tendon that is especially prevalent in people who are involved in jumping activities. Extracorporeal Shockwave Therapy is a relatively new treatment modality for tendinopathies. It seems to be a safe and promising part of the rehabilitation program for patellar tendinopathy. Extracorporeal Shockwave Therapy originally used focused shockwaves. Several years ago a new kind of shockwave therapy was introduced: radial shockwave therapy. Studies that investigate the effectiveness of radial shockwave therapy as treatment for patellar tendinopathy are scarce. Therefore the aim of this study is to compare the effectiveness of focussed shockwave therapy and radial shockwave therapy as treatments for patellar tendinopathy. Methods/design The TOPSHOCK study (Tendinopathy Of Patella SHOCKwave) is a two-armed randomised controlled trial in which the effectiveness of focussed shockwave therapy and radial shockwave therapy are directly compared. Outcome assessors and patients are blinded as to which treatment is given. Patients undergo three sessions of either focused shockwave therapy or radial shockwave therapy at 1-week intervals, both in combination with eccentric decline squat training. Follow-up measurements are scheduled just before treatments 2 and 3, and 1, 4, 7 and 12 weeks after the final treatment. The main outcome measure is the Dutch VISA-P questionnaire, which asks for pain, function and sports participation in subjects with patellar tendinopathy. Secondary outcome measures are pain determined with a VAS during ADL, sports and decline squats, rating of subjective improvement and overall satisfaction with the treatment. Patients will also record their sports activities, pain during and after these activities, and concurrent medical treatment on a weekly basis in a web-based diary. Results will be analysed according to the intention-to-treat principle. Discussion The TOPSHOCK study is the first randomised controlled trial that directly compares the effectiveness of focused shockwave therapy and radial shockwave therapy, both in combination with eccentric decline squat training, for treating patellar tendinopathy. Trial registration Trial registration number NTR2774. PMID:21989041

  3. Are unilateral and bilateral patellar tendinopathy distinguished by differences in anthropometry, body composition, or muscle strength in elite female basketball players?

    PubMed Central

    Gaida, J; Cook, J; Bass, S; Austen, S; Kiss, Z

    2004-01-01

    Background: Overuse injury to the patellar tendon (patellar tendinopathy) is a major reason for interrupted training and competition for elite athletes. In both sexes, the prevalence of unilateral and bilateral tendinopathy has been shown to differ. It has been proposed that bilateral pathology may have a different aetiology from unilateral pathology. Investigation of risk factors that may be unique to unilateral and bilateral patellar tendinopathy in female athletes may reveal insights into the aetiology of this condition. Objectives: To examine whether anthropometry, body composition, or muscle strength distinguished elite female basketball players with unilateral or bilateral patellar tendinopathy. Methods: Body composition, anthropometry, and muscle strength were compared in elite female basketball players with unilateral (n = 8), bilateral (n = 7), or no (n = 24) patellar tendinopathy. Body composition was analysed using a dual energy x ray absorptiometer. Anthropometric measures were assessed using standard techniques. Knee extensor strength was measured at 180°/s using an isokinetic dynamometer. z scores were calculated for the unilateral and bilateral groups (using the no tendinopathy group as controls). z scores were tested against zero. Results: The tibia length to stature ratio was approximately 1.3 (1.3) SDs above zero in both the affected and non-affected legs in the unilateral group (p<0.05). The waist to hip ratio was 0.66 (0.78) SD above zero in the unilateral group (p<0.05). In the unilateral group, leg lean to total lean ratio was 0.42 (0.55) SD above zero (p<0.07), the trunk lean to total lean ratio was 0.63 (0.68) SD below zero (p<0.05), and leg fat relative to total fat was 0.47 (0.65) SD below zero (p<0.09). In the unilateral group, the leg with pathology was 0.78 (1.03) SD weaker during eccentric contractions (p<0.07). Conclusions: Unilateral patellar tendinopathy has identifiable risk factors whereas bilateral patellar tendinopathy may not. This suggests that the aetiology of these conditions may be different. However, interpretation must respect the limitation of small subject numbers. PMID:15388543

  4. What Factors Influence the Biomechanical Properties of Allograft Tissue for ACL Reconstruction? A Systematic Review.

    PubMed

    Lansdown, Drew A; Riff, Andrew J; Meadows, Molly; Yanke, Adam B; Bach, Bernard R

    2017-10-01

    Allograft tissue is used in 22% to 42% of anterior cruciate ligament (ACL) reconstructions. Clinical outcomes have been inconsistent with allograft tissue, with some series reporting no differences in outcomes and others reporting increased risk of failure. There are numerous variations in processing and preparation that may influence the eventual performance of allograft tissue in ACL reconstruction. We sought to perform a systematic review to summarize the factors that affect the biomechanical properties of allograft tissue for use in ACL reconstruction. Many factors might impact the biomechanical properties of allograft tissue, and these should be understood when considering using allograft tissue or when reporting outcomes from allograft reconstruction. What factors affect the biomechanical properties of allograft tissue used for ACL reconstruction? We performed a systematic review to identify studies on factors that influence the biomechanical properties of allograft tissue through PubMed and SCOPUS databases. We included cadaveric and animal studies that reported on results of biomechanical testing, whereas studies on fixation, histologic evaluation, and clinical outcomes were excluded. There were 319 unique publications identified through the search with 48 identified as relevant to answering the study question. For each study, we recorded the type of tissue tested, parameters investigated, and the effects on biomechanical behavior, including load to failure and stiffness. Primary factors identified to influence allograft tissue properties were graft tissue type, sterilization methods (irradiation and chemical processing), graft preparation, donor parameters, and biologic adjuncts. Load to failure and graft stiffness varied across different tissue types, with nonlooped tibialis grafts exhibiting the lowest values. Studies on low-dose irradiation showed variable effects, whereas high-dose irradiation consistently produced decreased load to failure and stiffness values. Various chemical sterilization measures were also associated with negative effects on biomechanical properties. Prolonged freezing decreased load to failure, ultimate stress, and ultimate strain. Up to eight freeze-thaw cycles did not lead to differences in biomechanical properties of cadaveric grafts. Regional differences were noted in patellar tendon grafts, with the central third showing the highest load to failure and stiffness. Graft diameter strongly contributed to load-to-failure measurements. Age older than 40 years, and especially older than 65 years, negatively impacted biomechanical properties, whereas gender had minimal effect on the properties of allograft tissue. Biologic adjuncts show potential for improving in vivo properties of allograft tissue. Future clinical studies on allograft ACL reconstruction should investigate in vivo graft performance with standardized allograft processing and preparation methods that limit the negative effects on the biomechanical properties of tissue. Additionally, biologic adjuncts may improve the biomechanical properties of allograft tissue, although future preclinical and clinical studies are necessary to clarify the role of these treatments. Based on the findings of this systematic review that emphasize biomechanical properties of ACL allografts, surgeons should favor the use of central third patellar tendon or looped soft tissue grafts, maximize graft cross-sectional area, and favor grafts from donors younger than 40 years of age while avoiding grafts subjected to radiation doses > 20 kGy, chemical processing, or greater than eight freeze-thaw cycles.

  5. Collagen V haploinsufficiency in a murine model of classic Ehlers-Danlos syndrome is associated with deficient structural and mechanical healing in tendons.

    PubMed

    Johnston, Jessica M; Connizzo, Brianne K; Shetye, Snehal S; Robinson, Kelsey A; Huegel, Julianne; Rodriguez, Ashley B; Sun, Mei; Adams, Sheila M; Birk, David E; Soslowsky, Louis J

    2017-12-01

    Classic Ehlers-Danlos syndrome (EDS) patients suffer from connective tissue hyperelasticity, joint instability, skin hyperextensibility, tissue fragility, and poor wound healing due to heterozygous mutations in COL5a1 or COL5a2 genes. This study investigated the roles of collagen V in establishing structure and function in uninjured patellar tendons as well as in the injury response using a Col5a1 +/- mouse, a model for classic EDS. These analyses were done comparing tendons from a classic EDS model (Col5a1 +/- ) with wild-type controls. Tendons were subjected to mechanical testing, histological, and fibril analysis before injury as well as 3 and 6 weeks after injury. We found that Col5a1 +/- tendons demonstrated diminished recovery of mechanical competency after injury as compared to normal wild-type tendons, which recovered their pre-injury values by 6 weeks post injury. Additionally, the Col5a1 +/- tendons demonstrated altered fibril morphology and diameter distributions compared to the wild-type tendons. This study indicates that collagen V plays an important role in regulating collagen fibrillogenesis and the associated recovery of mechanical integrity in tendons after injury. In addition, the dysregulation with decreased collagen V expression in EDS is associated with a diminished injury response. The results presented herein have the potential to direct future targeted therapeutics for classic EDS patients. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2707-2715, 2017. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  6. Effect of daily short-duration weight-bearing on disuse-induced deterioration of musculoskeletal system

    PubMed Central

    Leung, K-S.; Li, Y-H.; Liu, Y.; Wang, H.; Tam, K-F.; Chow, D.H.K.; Wan, Y.; Ling, S.; Dai, Z.; Qin, L.; Cheung, W-H.

    2015-01-01

    Objectives: To investigate deterioration of musculoskeletal system due to prolonged disuse and the potential of daily short-duration weight-bearing as countermeasures. Methods: Twenty-four adult male Sprague-Dawley rats were divided into Control Group (CG, no intervention), Tail-suspension Group (TG, tail-suspension without treatment), and Weight-Bearing Group (WBG, tail-suspension with 20 min/day, 5 days/week body weight loading). After four weeks of treatment, femur and tibia, soleus and extensor digitorum longus were evaluated for bone and muscle quality respectively. Tensile properties of bone-tendon insertion (BTI) were evaluated using patella-patellar tendon complex. Results: Disuse induced deterioration on bone, muscle, and BTI after four weeks. Compared with CG, TG and WBG showed significant decrease in bone mineral density (BMD) of trabecular bone in distal femur (4.3-15.2%), muscle mass (31.3-52.3%), muscle cross-sectional area (29.1-35%), and failure strength of BTI (23.9-29.4%). Tensile test showed that the failure mode was avulsion of bone at the BTI. No significant difference was detected between TG and WBG for all assessments on bone, muscle, and BTI. Conclusions: Disuse caused deterioration of bone, muscle, and BTI while daily short-duration of weight-bearing did not prevent this deterioration. Mechanical stimulation with higher intensity and longer duration may be necessary to prevent musculoskeletal deterioration resulted from prolonged disuse. PMID:26032214

  7. Clinical Applications of Platelet-Rich Plasma in Patellar Tendinopathy

    PubMed Central

    Jeong, D. U.; Lee, C.-R.; Lee, J. H.; Pak, J.; Kang, L.-W.; Jeong, B. C.

    2014-01-01

    Platelet-rich plasma (PRP), a blood derivative with high concentrations of platelets, has been found to have high levels of autologous growth factors (GFs), such as transforming growth factor-β (TGF-β), platelet-derived growth factor (PDGF), fibroblastic growth factor (FGF), vascular endothelial growth factor (VEGF), and epidermal growth factor (EGF). These GFs and other biological active proteins of PRP can promote tissue healing through the regulation of fibrosis and angiogenesis. Moreover, PRP is considered to be safe due to its autologous nature and long-term usage without any reported major complications. Therefore, PRP therapy could be an option in treating overused tendon damage such as chronic tendinopathy. Here, we present a systematic review highlighting the clinical effectiveness of PRP injection therapy in patellar tendinopathy, which is a major cause of athletes to retire from their respective careers. PMID:25136568

  8. The medial patellofemoral complex.

    PubMed

    Loeb, Alexander E; Tanaka, Miho J

    2018-06-01

    The purpose of this review is to describe the current understanding of the medial patellofemoral complex, including recent anatomic advances, evaluation of indications for reconstruction with concomitant pathology, and surgical reconstruction techniques. Recent advances in our understanding of MPFC anatomy have found that there are fibers that insert onto the deep quadriceps tendon as well as the patella, thus earning the name "medial patellofemoral complex" to allow for the variability in its anatomy. In MPFC reconstruction, anatomic origin and insertion points and appropriate graft length are critical to prevent overconstraint of the patellofemoral joint. The MPFC is a crucial soft tissue checkrein to lateral patellar translation, and its repair or reconstruction results in good restoration of patellofemoral stability. As our understanding of MPFC anatomy evolves, further studies are needed to apply its relevance in kinematics and surgical applications to its role in maintaining patellar stability.

  9. Landing limb posture in volleyball athletes with patellar tendinopathy: a pilot study.

    PubMed

    Kulig, K; Joiner, D G; Chang, Y-J

    2015-05-01

    The aims of this pilot study were to investigate how a novel sagittal plane kinematic measurement - the lower extremity contact angle (LECA) - relates to the landing dynamics of elite male volleyball athletes with and without patellar tendinopathy. The LECA was defined as the angle between the ground and the line connecting the center of pressure to the L5S1 marker. 18 athletes (9 with patellar tendinopathy and 9 with asymptomatic tendons) completed simulated spike jumps while instrumented for kinetic and kinematic analysis using a force platform and 3D motion analysis system. The patellar tendinopathic group demonstrated a significantly more acute LECA compared to the asymptomatic group (65.3°±2.2° vs. 69.1°±4.5°) and was the only kinematic or kinetic variable measured to discriminate between the 2 groups. The LECA further demonstrated less variability between trials than sagittal plane hip, knee, and ankle kinematics. Additionally, the LECA's - and not individual joints' - high correlation with the braking impulse ensures its predictive value for landing dynamics (r=- 0.890). The LECA has the potential to be a valuable tool to help assess jumping athletes in both injury prevention screening and as a variable that, if modified, could help alter the maladaptive behavior observed in symptomatic athletes. © Georg Thieme Verlag KG Stuttgart · New York.

  10. Structural and in vivo mechanical characterization of canine patellar cartilage: a closed chondromalacia patellae model.

    PubMed

    LaBerge, M; Audet, J; Drouin, G; Rivard, C H

    1993-01-01

    The purpose of this project was to study the relationship between the structure of the patellar cartilage and its response to static compressive loading with a closed chondromalacia patellae model. An animal model was used to induce degeneration of the patella that was monitored quantitatively and qualitatively as a function of time. Ten adult mongrel dogs had their left patellofemoral groove replaced by a customized metallic implant covered with a thin film of polyethylene for periods of 3 months (five dogs) and 6 months (five dogs). An indenter was designed to perform mechanical indentation testing on the patellar cartilage in situ. The animals were anesthetized and the response of patellar cartilage to a static compressive load of 4.5 MPa was monitored for 20 min and its relaxation after load removal for 20 min. Indentation tests were performed every 3 months of the implantation period. At the end of the implantation period, the patellae were processed for histology, and sections were stained with Safranin-O indicative of the proteoglycans content. Macroscopically, no apparent degeneration or fibrillation of the patellar surfaces was observed after 3 or 6 months of implantation. However, the patellar surface showed a change in coloration after 6 months. A 17 +/- 3% and 37 +/- 8% deformation of the cartilage were calculated for the 3-month and 6-month specimens, respectively. Histologically, a progressive loss of proteoglycans was observed in the matrix as a function of implantation time. These results indicated that an increase in cartilage compliance is associated with an intrinsic remodeling of the cartilage matrix and that these changes might occur without external signs of degeneration and can be quantified.

  11. The anatomy and isometry of a quasi-anatomical reconstruction of the medial patellofemoral ligament.

    PubMed

    Pérez-Prieto, Daniel; Capurro, Bruno; Gelber, Pablo E; Ginovart, Gerard; Reina, Francisco; Sanchis-Alfonso, Vicente; Monllau, Joan C

    2017-08-01

    To describe the anatomy of the medial patellofemoral ligament (MPFL) and its relationship to the Adductor Magnus (AM) tendon as well as the behaviour exhibited in length changes during knee flexion. Ten cadaveric knees were dissected. The length from the superior and inferior patellar origin of the MPFL to its femoral insertion was measured at different degrees of knee flexion (0°, 30°, 60°, 90° and 120°). The same measures were made from both patellar origins of the MPFL up to the femoral insertion of the AM. The distance between the insertion of the AM and the Hunter canal was also measured. In general, isometry up to 90° was seen in all measures of the MPFL and those of the AM. The most isometric behaviour was seen in 2 measures: the length of the AM femoral insertion up to the inferior origin of the MPFL on the patella and the length of the femoral insertion of the MPFL up to the inferior origin of the MPFL on the patella. Similar behaviour was seen regardless of the anatomical or quasi-anatomical femoral point of attachment (n.s.). The distance from the AM tendon to the Hunter canal had a mean value of 78.6 mm (SD 9.4 mm). The behaviour exhibited during the changes in the length of the anatomical femoral footprint of the MPFL and the AM is similar. Neurovascular structures were not seen at risk. This is relevant in the daily clinical practice since the AM tendon might be a suitable point of insertion for MPFL reconstruction.

  12. The infrapatellar fat pad is a dynamic and mobile structure, which deforms during knee motion, and has proximal extensions which wrap around the patella.

    PubMed

    Stephen, Joanna M; Sopher, Ran; Tullie, Sebastian; Amis, Andrew A; Ball, Simon; Williams, Andy

    2018-04-20

    The infrapatellar fat pad (IFP) is a common cause of knee pain and loss of knee flexion and extension. However, its anatomy and behavior are not consistently defined. Thirty-six unpaired fresh frozen knees (median age 34 years, range 21-68) were dissected, and IFP attachments and volume measured. The rectus femoris was elevated, suprapatellar pouch opened and videos recorded looking inferiorly along the femoral shaft at the IFP as the knee was flexed. The patellar retinacula were incised and the patella reflected distally. The attachment of the ligamentum mucosum (LMuc) to the intercondylar notch was released from the anterior cruciate ligament (ACL), both menisci and to the tibia via meniscotibial ligaments. IFP strands projecting along both sides of the patella were elevated and the IFP dissected from the inferior patellar pole. Magnetic resonance imaging (MRI) of one knee at ten flexion angles was performed and the IFP, patella, tibia and femur segmented. In all specimens the IFP attached to the inferior patellar pole, femoral intercondylar notch (via the LMuc), proximal patellar tendon, intermeniscal ligament, both menisci and the anterior tibia via the meniscotibial ligaments. In 30 specimens the IFP attached to the anterior ACL fibers via the LMuc, and in 29 specimens it attached directly to the central anterior tibia. Proximal IFP extensions were identified alongside the patella in all specimens and visible on MRI [medially (100% of specimens), mean length 56.2 ± 8.9 mm, laterally (83%), mean length 23.9 ± 6.2 mm]. Mean IFP volume was 29.2 ± 6.1 ml. The LMuc, attached near the base of the middle IFP lobe, acting as a 'tether' drawing it superiorly during knee extension. The medial lobe consistently had a pedicle superomedially, positioned between the patella and medial trochlea. MRI scans demonstrated how the space between the anterior tibia and patellar tendon ('the anterior interval') narrowed during knee flexion, displacing the IFP superiorly and posteriorly as it conformed to the trochlear and intercondylar notch surfaces. Proximal IFP extensions are a novel description. The IFP is a dynamic structure, displacing significantly during knee motion, which is, therefore, vulnerable to interference from trauma or repetitive overload. Given that this trauma is often surgical, it may be appropriate that surgeons learn to minimize injury to the fat pad at surgery.

  13. The coupled effects of crouch gait and patella alta on tibiofemoral and patellofemoral cartilage loading in children.

    PubMed

    Brandon, Scott C E; Thelen, Darryl G; Smith, Colin R; Novacheck, Tom F; Schwartz, Michael H; Lenhart, Rachel L

    2018-02-01

    Elevated tibiofemoral and patellofemoral loading in children who exhibit crouch gait may contribute to skeletal deformities, pain, and cessation of walking ability. Surgical procedures used to treat crouch frequently correct knee extensor insufficiency by advancing the patella. However, there is little quantitative understanding of how the magnitudes of crouch and patellofemoral correction affect cartilage loading in gait. We used a computational musculoskeletal model to simulate the gait of twenty typically developing children and fifteen cerebral palsy patients who exhibited mild, moderate, and severe crouch. For each walking posture, we assessed the influence of patella alta and baja on tibiofemoral and patellofemoral cartilage contact. Tibiofemoral and patellofemoral contact pressures during the stance phase of normal gait averaged 2.2 and 1.0 MPa. Crouch gait increased pressure in both the tibofemoral (2.6-4.3 MPa) and patellofemoral (1.8-3.3 MPa) joints, while also shifting tibiofemoral contact to the posterior tibial plateau. For extended-knee postures, normal patellar positions (Insall-Salvatti ratio 0.8-1.2) concentrated contact on the middle third of the patellar cartilage. However, in flexed knee postures, both normal and baja patellar positions shifted pressure toward the superior edge of the patella. Moving the patella into alta restored pressure to the middle region of the patellar cartilage as crouch increased. This work illustrates the potential to dramatically reduce tibiofemoral and patellofemoral cartilage loading by surgically correcting crouch gait, and highlights the interaction between patella position and knee posture in modulating the location of patellar contact during functional activities. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Augmentation of Distal Biceps Repair With an Acellular Dermal Graft Restores Native Biomechanical Properties in a Tendon-Deficient Model.

    PubMed

    Conroy, Christine; Sethi, Paul; Macken, Craig; Wei, David; Kowalsky, Marc; Mirzayan, Raffy; Pauzenberger, Leo; Dyrna, Felix; Obopilwe, Elifho; Mazzocca, Augustus D

    2017-07-01

    The majority of distal biceps tendon injuries can be repaired in a single procedure. In contrast, complete chronic tears with severe tendon substance deficiency and retraction often require tendon graft augmentation. In cases with extensive partial tears of the distal biceps, a human dermal allograft may be used as an alternative to restore tendon thickness and biomechanical integrity. Dermal graft augmentation will improve load to failure compared with nonaugmented repair in a tendon-deficient model. Controlled laboratory study. Thirty-six matched specimens were organized into 1 of 4 groups: native tendon, native tendon with dermal graft augmentation, tendon with an attritional defect, and tendon with an attritional defect repaired with a graft. To mimic a chronic attritional biceps lesion, a defect was created by a complete tear, leaving 30% of the tendon's width intact. The repair technique in all groups consisted of cortical button and interference screw fixation. All specimens underwent cyclical loading for 3000 cycles and were then tested to failure; gap formation and peak load at failure were documented. The mean (±SD) load to failure (320.9 ± 49.1 N vs 348.8 ± 77.6 N, respectively; P = .38) and gap formation (displacement) (1.8 ± 1.4 mm vs 1.6 ± 1.1 mm, respectively; P = .38) did not differ between the native tendon groups with and without graft augmentation. In the tendon-deficient model, the mean load to failure was significantly improved with graft augmentation compared with no graft augmentation (282.1 ± 83.8 N vs 199.7 ± 45.5 N, respectively; P = .04), while the mean gap formation was significantly reduced (1.2 ± 1.0 mm vs 2.7 ± 1.4 mm, respectively; P = .04). The mean load to failure of the deficient tendon with graft augmentation (282.1 N) compared with the native tendon (348.8 N) was not significantly different ( P = .12). This indicates that the native tendon did not perform differently from the grafted deficient tendon. In a tendon-deficient, complete distal biceps rupture model, acellular dermal allograft augmentation restored the native tendon's biomechanical properties at time zero. The grafted tissue-deficient model demonstrated no significant differences in the load to failure and gap formation compared with the native tendon. As expected, dermal augmentation of attritional tendon repair increased the load to failure and stiffness as well as decreased displacement compared with the ungrafted tissue-deficient model. Tendons with their native width showed no statistical difference or negative biomechanical consequences of dermal augmentation. Dermal augmentation of the distal biceps is a biomechanically feasible option for patients with an attritionally thinned-out tendon.

  15. Biomechanical evaluation of various suture configurations in side-to-side tenorrhaphy.

    PubMed

    Wagner, Emilio; Ortiz, Cristian; Wagner, Pablo; Guzman, Rodrigo; Ahumada, Ximena; Maffulli, Nicola

    2014-02-05

    Side-to-side tenorrhaphy is increasingly used, but its mechanical performance has not been studied. Two porcine flexor digitorum tendon segments of equal length (8 cm) and thickness (1 cm) were placed side by side. Eight tenorrhaphies (involving sixteen tendons) were performed with each of four suture techniques (running locked, simple eight, vertical mattress, and pulley suture). The resulting constructs underwent cyclic loading on a tensile testing machine, followed by monotonically increasing tensile load if failure during cyclic loading did not occur. Clamps secured the tendons on each side of the repair, and specimens were mounted vertically. Cyclic loading varied between 15 N and 35 N, with a distension rate of 1 mm/sec. Cyclic loading strength was determined by applying a force of 70 N. The cause of failure and tendon distension during loading were recorded. All failures occurred in the monotonic loading phase and resulted from tendon stripping. No suture or knot failure was observed. The mean loads resisted by the configurations ranged from 138 to 398 N. The mean load to failure, maximum load resisted prior to 1 cm of distension, and load resisted at 1 cm of distension were significantly lower for the vertical mattress suture group than for any of the other three groups (p < 0.031). All four groups sustained loads well above the physiologic loads expected to occur in tendons in the foot and ankle (e.g., in tendon transfer for tibialis posterior tendon insufficiency). None of the four side-to-side configurations distended appreciably during the cyclic loading phase. The vertical mattress suture configuration appeared to be weaker than the other configurations. For surgeons who advocate immediate loading or motion of a side-to-side tendon repair, a pulley, running locked, or simple eight suture technique appears to provide a larger safety margin compared with a vertical mattress suture technique.

  16. Manipulation of Foot Strike and Footwear Increases Achilles Tendon Loading During Running.

    PubMed

    Rice, Hannah; Patel, Mubarak

    2017-08-01

    The Achilles tendon is the most common site of tendon overuse injury in humans. Running with a forefoot strike pattern and in minimal shoes is a topic of recent interest, yet evidence is currently limited regarding the combined influence of foot strike and footwear on Achilles tendon loading. To investigate the influence of both foot strike and footwear on Achilles tendon loading in habitual rearfoot strike runners. Controlled laboratory study. Synchronized kinematic and force data were collected from 22 habitual rearfoot strikers (11 male), who habitually ran in nonminimal running shoes, during overground running at 3.6 m·s -1 . Participants ran in 3 different footwear conditions (standard running shoe, minimal running shoe, and barefoot) with both a rearfoot strike (RFS) and an imposed forefoot strike (FFS) in each footwear condition. Achilles tendon loading was estimated by use of inverse dynamics, where the Achilles tendon moment arm was determined with a regression equation. A 2-way, repeated-measures analysis of variance was used to compare conditions. Achilles tendon impulse was greater when subjects ran with an FFS rather than an RFS in minimal shoes. Achilles tendon loading rates were higher when subjects ran either in minimal shoes or barefoot than in standard shoes, regardless of foot strike. In runners who habitually rearfoot strike in standard running shoes, running in minimal shoes or barefoot increased the rate of tendon loading, and running with a forefoot strike in minimal shoes increased the magnitude of tendon loading. Transitioning to these running conditions may increase the risk of tendinopathy.

  17. Ultrasound measures of tendon thickness: Intra-rater, Inter-rater and Inter-machine reliability.

    PubMed

    Del Baño-Aledo, María Elena; Martínez-Payá, Jacinto Javier; Ríos-Díaz, José; Mejías-Suárez, Silvia; Serrano-Carmona, Sergio; de Groot-Ferrando, Ana

    2017-01-01

    Ultrasound imaging is often used by physiotherapists and other healthcare professionals but the reliability of image acquisition with different ultrasound machines is unknown. The objective was to compare the intra-rater, inter-rater and intermachine reliability of thickness measurements of the plantar fascia (PF), Achilles tendon (AT), patellar tendon (PT) and elbow common extensor tendon (ECET) with musculoskeletal ultrasound imaging (MSUS). Tendon thickness was measured in four anatomical structures (14 participants, 28 images per tendon) by two sonographers and with two different ultrasound machines. Intraclass Correlation Coefficients (ICCs) and Bland-Altman plots were calculated. The standard error of measurement (SEM) and minimum detectable difference (MDD) were calculated. Inter-rater reliability was excellent for AT (ICC=0.98; 95% CI= 0.96-0.99) and very good for PT (ICC=0.85; 95% CI = 0.67-0.93) and ECET (ICC=0.81; 95% CI= 0.72-0.94). Reliability for PF was moderate, with an ICC of 0.63 (CI 95%= 0.20-0.83). Bland-Altman plot for inter-machine reliability showed a mean difference of 1 m for PF measurements and a mean difference of 4 m and 20 m for AT and PT. The relative SEMs were below 7% and the MDCs were below 0.7 mm. The MSUS reliability in measuring thickness of the four tendons is confirmed by the homogeneous readings intra sonographers, between operators and between different machines. Level of evidence: Tendon thickness can be measured reliably on different ultrasound devices, which is an important step forward in the use of this technique in daily clinical practice and research. III.

  18. Measuring Regional Changes in Damaged Tendon

    NASA Astrophysics Data System (ADS)

    Frisch, Catherine Kayt Vincent

    Mechanical properties of tendon predict tendon health and function, but measuring these properties in vivo is difficult. An ultrasound-based (US) analysis technique called acoustoelastography (AE) uses load-dependent changes in the reflected US signal to estimate tissue stiffness non-invasively. This thesis explores whether AE can provide information about stiffness alteration resulting from tendon tears both ex vivo and in vivo. An ex vivo ovine infraspinatus tendon model suggests that the relative load transmitted by the different tendon layers transmit different fractions of the load and that ultrasound echo intensity change during cyclic loading decreases, becoming less consistent once the tendon is torn. An in vivo human tibialis anterior tendon model using electrically stimulated twitch contractions investigated the feasibility of measuring the effect in vivo. Four of the five subjects showed the expected change and that the muscle contraction times calculated using the average grayscale echo intensity change compared favorably with the times calculated based on the force data. Finally an AE pilot study with patients who had rotator cuff tendon tears found that controlling the applied load and the US view of the system will be crucial to a successful in vivo study.

  19. Superolateral Hoffa's Fat Pad Edema in Collegiate Volleyball Players.

    PubMed

    Mehta, Kaushal; Wissman, Robert; England, Eric; Dʼheurle, Albert; Newton, Keith; Kenter, Keith

    2015-01-01

    Superolateral Hoffa's fat pad (SHFP) edema is a previously described magnetic resonance (MR) finding located between the patellar tendon and the lateral femoral condyle. The purpose of our study was to determine the prevalence and clinical significance of SHFP edema in female collegiate volleyball players. Sixteen female collegiate volleyball players were consented for bilateral knee evaluations which consisted of history, physical examination and MR imaging. Each MR study was reviewed for the presence of SHFP edema, and 6 patellar maltracking measurements were done. These were tibial tuberosity-trochlear groove distance, patellar translation, lateral patellofemoral angle, trochlear depth, trochlear sulcus angle, and lateral trochlear inclination angle. A total of 16 athletes, 32 knees (16 girls; age range, 18-22 years; mean, 19.9) were enrolled in the study. Sixteen knees (50%) in 8 athletes had SHFP edema, with 100% bilaterality; 16 knees in 8 athletes had no evidence of SHFP edema (50%). Functional outcomes and physical examination findings were within normal limits for all athletes with no difference noted between SHFP edema-positive and -negative individuals. There was a statistically significant difference in the tibial tuberosity-trochlear groove distance, patellar translation, and patellofemoral angle (P value of < 0.001, 0.03 and 0.01, respectively) between the SHFP edema-positive and -negative individuals. Elite female volleyball athletes have a very high prevalence of SHFP edema, which is always bilateral. Although the exact etiology of SHFP edema remains inconclusive, it could potentially be a sensitive indicator of subtle patellar maltracking which cannot be distinguished by history and physical examination findings. Given the very high prevalence of SHFP edema and this being an asymptomatic finding, there is likely little clinical significance of this in majority of high-performance athletes.

  20. Pain in donor site after BTB-ACL reconstruction with PRGF: a randomized trial.

    PubMed

    Seijas, Roberto; Cuscó, Xavier; Sallent, Andrea; Serra, Iván; Ares, Oscar; Cugat, Ramón

    2016-06-01

    Anterior cruciate ligament (ACL) tears are highly incident injuries in young athletes within our work area. The use of the patellar graft, despite being the treatment of choice, presents post-operative problems such as anterior knee pain, which limits its use and leads to preference being taken for alternative grafts. Our aim was to evaluate if the application of PRGF reduces anterior knee pain in donor site in BTB-ACL reconstruction. 43 patients were included in the double-blinded and randomized clinical trial comparing two patient groups who underwent ACL reconstruction using patellar tendon graft, comparing anterior knee pain with and without the application of PRGF at the donor site after harvesting the graft. The PRGF group showed decreased donor site pain in comparison to the control group, with significant differences in the first two months of follow-up. The application of PRGF decreased donor site pain compared to the control group.

  1. In-vivo patellar tracking in individuals with patellofemoral pain and healthy individuals.

    PubMed

    Esfandiarpour, Fateme; Lebrun, Constance M; Dhillon, Sukhvinder; Boulanger, Pierre

    2018-02-28

    Understanding of the exact cause of patellofemoral pain has been limited by methodological challenges to evaluate in-vivo joint motion. This study compared six degree-of-freedom patellar motion during a dynamic lunge task between individuals with patellofemoral pain and healthy individuals. Knee joints of eight females with patellofemoral pain and ten healthy females were imaged using a CT scanner in supine lying position, then by a dual-orthogonal fluoroscope while they performed a lunge. To quantify patellar motion, the three-dimensional models of the knee bones, reconstructed from CT scans, were registered on the fluoroscopy images using the Fluomotion registration software. At full knee extension, the patella was in a significantly laterally tilted (PFP: 11.77° ± 7.58° vs. healthy: 0.86° ± 4.90°; p = 0.002) and superiorly shifted (PFP: 17.49 ± 8.44 mm vs. healthy: 9.47 ± 6.16 mm, p = 0. 033) position in the patellofemoral pain group compared with the healthy group. There were also significant differences between the groups for patellar tilt at 45°, 60°, and 75° of knee flexion, and for superior-inferior shift of the patella at 30° flexion (p ≤ 0.031). In the non-weight-bearing knee extended position, the patella was in a significantly laterally tilted position in the patellofemoral pain group (7.44° ± 6.53°) compared with the healthy group (0.71° ± 4.99°). These findings suggest the critical role of passive and active patellar stabilizers as potential causative factors for patellar malalignment/maltracking. Future studies should investigate the associations between patellar kinematics with joint morphology, muscle activity, and tendon function in a same sample for a thorough understanding of the causes of patellofemoral pain. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  2. Increased supraspinatus tendon thickness following fatigue loading in rotator cuff tendinopathy: potential implications for exercise therapy.

    PubMed

    McCreesh, Karen M; Purtill, Helen; Donnelly, Alan E; Lewis, Jeremy S

    2017-01-01

    Exercise imparts a load on tendon tissue that leads to changes in tendon properties. Studies suggest that loading immediately reduces tendon thickness, with a loss of this response in symptomatic tendinopathy. No studies investigating the response of tendon dimensions to load for the rotator cuff tendons exist. This study aimed to examine the short-term effect of loading on the thickness of the supraspinatus tendon and acromiohumeral distance those with and without rotator cuff tendinopathy. Participants were 20 painfree controls, and 23 people with painful rotator cuff tendinopathy. Supraspinatus tendon thickness and acromiohumeral distance were measured using ultrasound scans before, and at three time points after loading (1, 6 and 24 hours). Loading involved isokinetic eccentric and concentric external rotation and abduction. There was a significant increase in supraspinatus tendon thickness in the pain group at 1 (7%, ∆=0.38, 95% CI 0.19 to 0.57) and 6 hours (11%, ∆=0.53, 95% CI 0.34 to 0.71), although only the 6 hours difference exceeded minimal detectable difference. In contrast, there was a small non-significant reduction in thickness in controls. The acromiohumeral distance reduced significantly in both groups at 1 hour (controls: ∆=0.64, 95% CI 0.38 to 0.90; pain: ∆=1.1, 95% CI 0.85 to 1.33), with a larger change from baseline in the pain group. Those diagnosed with painful supraspinatus tendinopathy demonstrated increased thickening with delayed return to baseline following loading. Rehabilitation professionals may need to take into account the impact of loading to fatigue when planning rehabilitation programmes.

  3. Increased supraspinatus tendon thickness following fatigue loading in rotator cuff tendinopathy: potential implications for exercise therapy

    PubMed Central

    McCreesh, Karen M; Purtill, Helen; Donnelly, Alan E; Lewis, Jeremy S

    2017-01-01

    Background/aim Exercise imparts a load on tendon tissue that leads to changes in tendon properties. Studies suggest that loading immediately reduces tendon thickness, with a loss of this response in symptomatic tendinopathy. No studies investigating the response of tendon dimensions to load for the rotator cuff tendons exist. This study aimed to examine the short-term effect of loading on the thickness of the supraspinatus tendon and acromiohumeral distance those with and without rotator cuff tendinopathy. Methods Participants were 20 painfree controls, and 23 people with painful rotator cuff tendinopathy. Supraspinatus tendon thickness and acromiohumeral distance were measured using ultrasound scans before, and at three time points after loading (1, 6 and 24 hours). Loading involved isokinetic eccentric and concentric external rotation and abduction. Results There was a significant increase in supraspinatus tendon thickness in the pain group at 1 (7%, ∆=0.38, 95% CI 0.19 to 0.57) and 6 hours (11%, ∆=0.53, 95% CI 0.34 to 0.71), although only the 6 hours difference exceeded minimal detectable difference. In contrast, there was a small non-significant reduction in thickness in controls. The acromiohumeral distance reduced significantly in both groups at 1 hour (controls: ∆=0.64, 95% CI 0.38 to 0.90; pain: ∆=1.1, 95% CI 0.85 to 1.33), with a larger change from baseline in the pain group. Conclusion Those diagnosed with painful supraspinatus tendinopathy demonstrated increased thickening with delayed return to baseline following loading. Rehabilitation professionals may need to take into account the impact of loading to fatigue when planning rehabilitation programmes. PMID:29333279

  4. Biomechanical study of patellofemoral joint instability

    NASA Astrophysics Data System (ADS)

    Senavongse, Wongwit

    2005-04-01

    Patellofemoral joint instability is a complex clinical problem. It may be a consequence of pre-existing anatomical abnormality or trauma. The objectives of this study were to use experimental mechanics to measure patellar stability and to quantify the effects of pathological abnormalities on patellar stability in vitro. Eight fresh-frozen cadaver knees were studies. The patellar stability was measured using an Instron material testing machine. A total load of 175N was applied to the quadriceps muscles. Patellar force-displacement was tested at different knee flexion angles as the patella was cyclically displaced 10mm laterally and medially. Three pathological abnormalities were applied; VMO malfunction, flat lateral trochlea, and medial retinacular structure rupturing. For the first time, this study has shown comparative and quantitative influence of pathological abnormalities on patellar stability. It was found that a flat lateral trochlea has greater effect than the medial retinacular rupturing whereas the medial retinacular rupturing has greater effect than VMO malfunction on patellar lateral stability. These results are important for future investigations on the treatment of patellofemoral instability.

  5. Effects of foot orthoses on Achilles tendon load in recreational runners.

    PubMed

    Sinclair, J; Isherwood, J; Taylor, P J

    2014-09-01

    Achilles tendon pathology is a frequently occurring musculoskeletal disorder in runners. Foot orthoses have been shown to reduce the symptoms of pain in runners but their mechanical effects are still not well understood. This study aimed to examine differences in Achilles tendon load when running with and without orthotic intervention. Twelve male runners ran at 4.0 m·s(-1). Ankle joint moments and Achilles tendon forces were compared when running with and without orthotics. The results indicate that running with foot orthotics was associated with significant reductions in Achilles tendon load compared to without orthotics. In addition to providing insight into the mechanical effects of orthotics in runners, the current investigation suggests that via reductions in Achilles tendon load, foot orthoses may serve to reduce the incidence of chronic Achilles tendon pathologies in runners. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Does Patellar Eversion in Total Knee Arthroplasty Cause Patella Baja?

    PubMed Central

    Sharma, Vineet; Tsailas, Panagiotis G.; Maheshwari, Aditya V.; Ranawat, Chitranjan S.

    2008-01-01

    Several proponents of minimally invasive surgery-total knee arthroplasty (MIS-TKA) have suggested patellar eversion during a standard exposure of the knee may cause shortening of the patellar tendon and poorer outcomes secondary to acquired patella baja. To explore this suggestion, we retrospectively reviewed 135 consecutive TKAs in 110 patients to ascertain the effect of TKA on the postoperative Insall-Salvati ratio. All surgeries were performed using standard TKA techniques with a midline incision, medial parapatellar arthrotomy, partial excision of the fat pad, and routine eversion of the patella. One patient developed a postoperative patella baja, defined as an Insall-Salvati ratio of less than 0.8. The Knee Society score for knee and function in this patient was 75 and 70, respectively. Five additional patients had a decrease in Insall-Salvati ratio by 10% or more but without patella baja. Mean Knee Society score for knee and function in these five patients was 94 (range, 73–99) and 96 (range, 90–100), respectively, as compared with 93 (range, 37–99) and 94 (range, 40–100) in the remaining 104 patients. Our data suggest the incidence of patella baja is low after TKA despite routine patellar eversion. Furthermore, a 10% or more decrease in the Insall-Salvati ratio without patella baja was not associated with a worse clinical outcome. Level of Evidence: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence. PMID:18568378

  7. Effect of cyclic and static tensile loading on water content and solute diffusion in canine flexor tendons: an in vitro study.

    PubMed

    Hannafin, J A; Arnoczky, S P

    1994-05-01

    This study was designed to determine the effects of various loading conditions (no load and static and cyclic tensile load) on the water content and pattern of nutrient diffusion of canine flexor tendons in vitro. Region D (designated by Okuda et al.) of the flexor digitorum profundus was subjected to a cyclic or static tensile load of 100 g for times ranging from 5 minutes to 24 hours. The results demonstrated a statistically significant loss of water in tendons subjected to both types of load as compared with the controls (no load). This loss appeared to progress with time. However, neither static nor cyclic loading appeared to alter the diffusion of 3H-glucose into the tendon over a 24-hour period compared with the controls. These results suggest that any benefit in tendon repair derived from intermittent passive motion is probably not a result of an increase in the diffusion of small nutrients in response to intermittent tensile load.

  8. Response of tibialis anterior tendon to a chronic exposure of stretch-shortening cycles: age effects

    PubMed Central

    Ensey, James S; Hollander, Melinda S; Wu, John Z; Kashon, Michael L; Baker, Brent B; Cutlip, Robert G

    2009-01-01

    Background The purpose of the current study was to investigate the effects of aging on tendon response to repetitive exposures of stretch-shortening cycles (SSC's). Methods The left hind limb from young (3 mo, N = 4) and old (30 mo, N = 9) male Fisher 344 × Brown Norway rats were exposed to 80 maximal SSCs (60 deg/s, 50 deg range of motion) 3x/week for 4.5 weeks in vivo. After the last exposure, tendons from the tibialis anterior muscle were isolated, stored at -80°C, and then tested using a micro-mechanical testing machine. Deformation of each tendon was evaluated using both relative grip-to-grip displacements and reference marks via a video system. Results At failure, the young control tendons had higher strain magnitude than the young exposed (p < 0.01) and the old control tendons (p < .0001). Total load at inflection was affected by age only (p < 0.01). Old exposed and control tendons exhibited significantly higher loads at the inflection point than their young counterparts (p < 0.05 for both comparisons). At failure, the old exposed tendons carried higher loads than the young exposed tendons (p < 0.05). Stiffness was affected by age only at failure where the old tendons exhibited higher stiffness in both exposed and control tendons than their young counterparts (p < 0.05 and p < 0.01, respectively). Conclusion The chronic protocol enhanced the elastic stiffness of young tendon and the loads in both the young and old tendons. The old exposed tendons were found to exhibit higher load capacity than their younger counterparts, which differed from our initial hypothesis. PMID:19563638

  9. Biomechanical characteristics of the horizontal mattress stitch: implication for double-row and suture-bridge rotator cuff repair.

    PubMed

    Tamboli, Mallika; Mihata, Teruhisa; Hwang, James; McGarry, Michelle H; Kang, Yangmi; Lee, Thay Q

    2014-03-01

    We investigated the effects of bite-size horizontal mattress stitch (distance between the limbs passed through the tendon) on the biomechanical properties of the repaired tendon. We anchored 20 bovine Achilles tendons to bone using no. 2 high-strength suture and 5-mm titanium suture anchors in a mattress-suture technique. Tendons were allocated randomly into two groups of ten each to receive stitches with a 4- or 10-mm bite. Specimens underwent cyclic loading from 5 to 30 N at 1 mm/s for 30 cycles, followed by tensile testing to failure. Gap formation, tendon strain, hysteresis, stiffness, yield load, ultimate load, energy to yield load, and energy to ultimate load were compared between groups using unpaired t tests. The 4-mm group had less (p < 0.05) gap formation and less (p < 0.05) longitudinal strain than did the 10-mm group. Ultimate load (293.6 vs. 148.9 N) and energy to ultimate load (2,563 vs. 1,472 N-mm) were greater (p < 0.001) for the 10-mm group than the 4-mm group. All tendons repaired with 4-mm suturing failed at the suture-tendon interface, with sutures pulling through the tendon, whereas the suture itself failed before the tendon did in seven of the ten specimens in the 10-mm group. Whereas a 4-mm bite fixed the tendon more tightly but at the cost of decreased ultimate strength, a 10-mm bite conveyed greater ultimate strength but with increased gap and strain. These results suggest that for the conventional double-row repair, small mattress stitches provide a tighter repair, whereas large stitches are beneficial to prevent sutures from pulling through the tendon after surgery. For suture-bridge rotator cuff repair, large stitches are beneficial because the repaired tendon has a higher strength, and the slightly mobile medial knot can be tightened by lateral fixation.

  10. Current concepts of etiology and treatment of chondromalacia patellae.

    PubMed

    Bentley, G; Dowd, G

    1984-10-01

    Chondromalacia patellae is a distinct clinical entity characterized by retropatellar pain that is associated with recognizable changes in the articular cartilage of the posterior surface of the patella. Several factors may be involved in the etiology, such as severe patella alta, trauma, and, in rare cases, abnormal patellar tracking. Clinical symptoms and signs are reliable in only 50% of cases, but measurable quadriceps wasting, palpable patellofemoral crepitus, and effusion are strongly suggestive. Diagnosis must be confirmed by arthroscopy or direct examination of the posterior surface of the patella. Radiologic measurements of patellofemoral relations are of limited value in diagnosis. The initial pathologic finding is usually surface cartilage breakdown. Radioisotope studies show cartilage cell replication which suggests a healing capacity in early cases following treatment that alters the load through the affected cartilage. There is no evidence of progression to patellofemoral osteoarthritis, which is probably a different entity. The treatment should be conservative where possible with isometric quadriceps exercises and simple anti-inflammatory drugs such as aspirin. Operative treatment is indicated for patients with persistent pain and macroscopic involvement of more than half a centimeter of the articular cartilage surface. The simplest effective procedure that avoids quadriceps dysfunction and fibrosis is a distal patellar tendon medial realignment with lateral release and medial reefing of the quadriceps expansion. Patellectomy is indicated in more extensive involvement of the patella of 2 or more centimeters in diameter, but this must be performed only when the patient has excellent quadriceps function before surgery and is motivated to exercise after surgery.

  11. Eccentric Training for Tendon Healing After Acute Lesion: A Rat Model.

    PubMed

    Kaux, Jean-François; Libertiaux, Vincent; Leprince, Pierre; Fillet, Marianne; Denoel, Vincent; Wyss, Clémence; Lecut, Christelle; Gothot, André; Le Goff, Caroline; Croisier, Jean-Louis; Crielaard, Jean-Michel; Drion, Pierre

    2017-05-01

    The tendon is a dynamic entity that remodels permanently. Platelet-rich plasma (PRP) injection has been shown to have a beneficial effect on tendon healing after lesion in rats. Furthermore, eccentric exercise seems to improve the mechanical quality of the tendon. A combination of PRP injection and eccentric training might be more effective than either treatment alone. Controlled laboratory study. Adult male rats were anesthetized, an incision was performed in the middle of their left patellar tendon and an injection of physiological fluid (PF) or homologous PRP was randomly made at the lesion level. The rats were then divided into 2 groups: the eccentric group, undergoing eccentric training 3 times a week, and the untrained group, without any training. Thus, 4 groups were compared. After 5 weeks, the tendons were removed and their ultimate tensile strength and energy were measured. Tendons were frozen for proteomic analyses when all biomechanical tests were completed. Statistical analysis was performed with linear mixed effect models. No significant difference was found between the treatments using PF injection or PRP injection alone. However, the value of the ultimate tensile force at rupture was increased by 4.5 N (108% of control, P = .006) when eccentric training was performed. An intragroup analysis revealed that eccentric training significantly improved the ultimate force values for the PRP group. Proteomic analysis revealed that eccentric training led to an increase in abundance of several cytoskeletal proteins in the PF group, while a decrease in abundance of enzymes of the glycolytic pathway occurred in the PRP-treated groups, indicating that this treatment might redirect the exercise-driven metabolic plasticity of the tendon. Eccentric training altered the metabolic plasticity of tendon and led to an improvement of injured tendon resistance regardless of the treatment injected (PF or PRP). This study demonstrates the necessity of eccentric rehabilitation and training in cases of tendon lesion regardless of the treatment carried out.

  12. Presence of enthesopathy in patients with primary Sjogren's syndrome: ultrasonographic study of a local cohort.

    PubMed

    Sag, Sinem; Sag, Mustafa Serdar; Tekeoglu, Ibrahim; Kamanlı, Ayhan; Nas, Kemal

    2018-01-01

    Musculoskeletal findings in Sjögren's syndrome are arthralgia, arthritis, myalgia, myositis, fibromyalgia, and chronic fatigue. Enthesis zones are important in the formation of pain in the musculoskeletal system. Musculoskeletal ultrasound (US) may show subclinical enthesitis in the synovial joints and in the axial skeleton before joint swelling in inflammatory diseases characterized by arthritis. In this study, we aimed to determine the presence of enthesopathy using the Madrid sonographic enthesitis index (MASEI) in patients with primary Sjögren's syndrome (PSS). Consecutive patients with PSS and age-matched healthy controls were included in this study. All the patients met the 2002 American College of Rheumatology/European League against Rheumatism classification criteria for PSS. The demographic characteristics of the patients were recorded. Six enthesis sites were evaluated using gray-scale and Doppler US with a linear transducer, and they were scored using the MASEI. They were assessed by the EULAR Sjögren's syndrome disease activity index (ESSDAI). We evaluated 40 patients with PSS (average age 48.67 ± 11.23 years) and 30 healthy controls (average age 45.40 ± 8.24 years). Patients with PSS had significantly higher MASEI scores than the healthy controls. Plantar fascia, Achilles tendon, and distal patellar tendons were significantly thicker in the PSS group than in the healthy controls. The MASEI total score had a positive correlation with age. There was no correlation between MASEI total score and BMI and ESSDAI. In this study, it was shown that the MASEI scores assessed by US were significantly higher in patients with PSS than in healthy controls. Plantar fascia, Achilles tendon, and distal patellar tendon were significantly thicker in the PSS group than in the healthy controls. This result suggests that PSS may be one of the causes of musculoskeletal pain that can be seen in patients with PSS. Our study was the first study to use an enthesis index ultrasonographically in patients with PSS. In addition, it is the first study to investigate the relationship between the presence of enthesopathy and disease activity by means of US.

  13. Inflammatory process induced by carrageenan in adjacent tissue triggers the acute inflammation in deep digital flexor tendon of rats.

    PubMed

    Vieira, Cristiano Pedrozo; De Aro, Andrea Aparecida; Da Ré Guerra, Flávia; De Oliveira, Letícia Prado; De Almeida, Marcos Dos Santos; Pimentel, Edson Rosa

    2013-08-01

    Tendinopathy is a pathology found mainly in the rotator cuff, patellar, Achilles and flexor tendons. Tendinopathy is a significant impediment to performance in athletes and in workers in the labor market. Some studies have indicated that inflammation in adjacent tissues may affect the rotator cuff and Achilles tendon. In this study alterations were verified in the extracellular matrix (ECM) of the deep digital flexor tendon after two periods (12 and 24 hr) of induction inflammation in rat paw. Wistar rats were divided into three groups: those that received injection of 1% carrageenan; those that received 0.9% NaCl; and those that received no application. The tendon was divided into distal (d), proximal (p), and intermediate (i) regions. Biochemical analyses were performed and included non-collagenous proteins (NCP), glycosaminoglycans (GAGs), hydroxyproline (HoPro) and metalloproteinases 2 and 9. Tissue sections were stained with toluidine blue, hematoxylin-eosin, and Ponceau SS and observed under polarization microscopy. Remarkable results were detected that included the presence of MMP-9, degradation of NCP and GAG and the presence of cellular infiltrate closer to digits in d region. The different concentrations of HoPro, as well as alterations in the organization of the collagen fibers showed the collagenous matrix undergoing some alterations. The results indicated that the induced inflammation in rat paw exhibited characteristics similar to the typical acute inflammatory process observed in tendons. Copyright © 2013 Wiley Periodicals, Inc.

  14. Increasing Running Step Rate Reduces Patellofemoral Joint Forces

    PubMed Central

    Lenhart, Rachel L.; Thelen, Darryl G.; Wille, Christa M.; Chumanov, Elizabeth S.; Heiderscheit, Bryan C.

    2013-01-01

    Purpose Increasing step rate has been shown to elicit changes in joint kinematics and kinetics during running, and has been suggested as a possible rehabilitation strategy for runners with patellofemoral pain. The purpose of this study was to determine how altering step rate affects internal muscle forces and patellofemoral joint loads, and then to determine what kinematic and kinetic factors best predict changes in joint loading. Methods We recorded whole body kinematics of 30 healthy adults running on an instrumented treadmill at three step rate conditions (90%, 100%, and 110% of preferred step rate). We then used a 3D lower extremity musculoskeletal model to estimate muscle, patellar tendon, and patellofemoral joint forces throughout the running gait cycles. Additionally, linear regression analysis allowed us to ascertain the relative influence of limb posture and external loads on patellofemoral joint force. Results Increasing step rate to 110% of preferred reduced peak patellofemoral joint force by 14%. Peak muscle forces were also altered as a result of the increased step rate with hip, knee and ankle extensor forces, and hip abductor forces all reduced in mid-stance. Compared to the 90% step rate condition, there was a concomitant increase in peak rectus femoris and hamstring loads during early and late swing, respectively, at higher step rates. Peak stance phase knee flexion decreased with increasing step rate, and was found to be the most important predictor of the reduction in patellofemoral joint loading. Conclusion Increasing step rate is an effective strategy to reduce patellofemoral joint forces and could be effective in modulating biomechanical factors that can contribute to patellofemoral pain. PMID:23917470

  15. Effect of Achilles tendon loading on plantar fascia tension in the standing foot.

    PubMed

    Cheung, Jason Tak-Man; Zhang, Ming; An, Kai-Nan

    2006-02-01

    The plantar fascia, which is one of the major arch-supporting structures of the human foot, sustains high tensions during weight-bearing. A positive correlation between Achilles tendon loading and plantar fascia tension has been reported. Excessive stretching and tightness of the Achilles tendon are thought to be the risk factors of plantar fasciitis but their biomechanical effects on the plantar fascia have not been fully addressed. A three-dimensional finite element model of the human foot and ankle, incorporating geometrical and material nonlinearity, was employed to investigate the loading response of the plantar fascia in the standing foot with different magnitudes of Achilles tendon loading. With the total ground reaction forces of one foot maintained at 350 N to represent half body weight, an increase in Achilles tendon load from (0-700 N) resulted in a general increase in total force and peak plantar pressure at the forefoot of up to about 250%. There was a lateral and anterior shift of the centre of pressure and a reduction in the arch height with an increasing Achilles tendon load as a result of the plantar flexion moment on the calcaneus. From the finite element predictions of simulated balanced standing, Achilles tendon forces of 75% of the total weight on the foot (350 N) were found to provide the closest match of the measured centre of pressure of the subject during balanced standing. Both the weight on the foot and Achilles tendon loading resulted in an increase in tension of the plantar fascia with the latter showing a two-times larger straining effect. Increasing tension on the Achilles tendon is coupled with an increasing strain on the plantar fascia. Overstretching of the Achilles tendon resulting from intense muscle contraction and passive stretching of tight Achilles tendon are plausible mechanical factors for overstraining of the plantar fascia.

  16. Evaluation of the clavicular tunnel placement on coracoclavicular ligament reconstruction for acromioclavicular dislocations: a finite element analysis.

    PubMed

    Kocadal, Onur; Yüksel, Korcan; Güven, Melih

    2018-01-27

    The two-tunnel coracoclavicular ligament reconstruction (CLR) technique is one of the treatment approaches commonly used in the surgical treatment of acromioclavicular (AC) injuries. Clavicular tunnel malposition is one of the major causes of failure in coracoclavicular ligament reconstruction. The main purpose of this study was to investigate the effects of clavicular tunnel placement on tendon loading in the CLR technique with finite element analysis. Models of clavicle and scapula were constructed using computerized tomography images. Two clavicular bone tunnel reconstruction models were created with the tendon passing through the conoid and trapezoid tunnels. Four models based on the tunnel ratio (TR) method and defined as primary, anatomic, medialized, and lateralized were constructed to evaluate the effect of tunnel placement on loading conditions during tendon graft. All models were loaded by insertion from the trapezius and sternocleidomastoid muscles. The loading on the tendon were evaluated with the finite element analysis. The highest load value measured on the tendon was in the anatomic model (0.789 kPa), and the lowest load value (0.598 kPa) was measured in the lateralized tunnel model. The load value of the primary model was (0.657 kPa), and the medialized model's value was (0.752 kPa). In two-tunnel CLR technique, tendon loadings are related to tunnel placement. Medialized tunnel placement increases tendon loading. The TR method may be an appropriate option for determining tunnel placement.

  17. Power amplification in an isolated muscle–tendon unit is load dependent

    PubMed Central

    Sawicki, Gregory S.; Sheppard, Peter; Roberts, Thomas J.

    2015-01-01

    ABSTRACT During rapid movements, tendons can act like springs, temporarily storing work done by muscles and then releasing it to power body movements. For some activities, such as frog jumping, energy is released from tendon much more rapidly than it is stored, thus amplifying muscle power output. The period during which energy is loaded into a tendon by muscle work may be aided by a catch mechanism that restricts motion, but theoretical studies indicate that power can be amplified in a muscle–tendon load system even in the absence of a catch. To explore the limits of power amplification with and without a catch, we studied the bullfrog plantaris muscle–tendon during in vitro contractions. A novel servomotor controller allowed us to measure muscle–tendon unit (MTU) mechanical behavior during contractions against a variety of simulated inertial-gravitational loads, ranging from zero to 1× the peak isometric force of the muscle. Power output of the MTU system was load dependent and power amplification occurred only at intermediate loads, reaching ∼1.3× the peak isotonic power output of the muscle. With a simulated anatomical catch mechanism in place, the highest power amplification occurred at the lowest loads, with a maximum amplification of more than 4× peak isotonic muscle power. At higher loads, the benefits of a catch for MTU performance diminished sharply, suggesting that power amplification >2.5× may come at the expense of net mechanical work delivered to the load. PMID:26449973

  18. THE ROLE OF MECHANOBIOLOGY IN TENDON HEALING

    PubMed Central

    Killian, Megan L.; Cavinatto, Leonardo; Galatz, Leesa M.; Thomopoulos, Stavros

    2011-01-01

    Mechanical cues affect tendon healing, homeostasis, and development in a variety of settings. Alterations in the mechanical environment are known to result in changes in the expression of extracellular matrix proteins, growth factors, transcription factors, and cytokines that can alter tendon structure and cell viability. Loss of muscle force in utero or in the immediate postnatal period delays tendon and enthesis development. The response of healing tendons to mechanical load varies depending on anatomic location. Flexor tendons require motion to prevent adhesion formation, yet excessive force results in gap formation and subsequent weakening of the repair. Excessive motion in the setting of anterior cruciate ligament reconstruction causes accumulation of macrophages, which are detrimental to tendon graft healing. Complete removal of load is detrimental to rotator cuff healing, yet large forces are also harmful. Controlled loading can enhance healing in most settings; however, a fine balance must be reached between loads that are too low (leading to a catabolic state) and too high (leading to micro-damage). This review will summarize existing knowledge of the mechanobiology of tendon development, homeostasis, and healing. PMID:22244066

  19. The mechanism for efficacy of eccentric loading in Achilles tendon injury; an in vivo study in humans.

    PubMed

    Rees, J D; Lichtwark, G A; Wolman, R L; Wilson, A M

    2008-10-01

    Degenerative disorders of tendons present an enormous clinical challenge. They are extremely common, prone to recur and existing medical and surgical treatments are generally unsatisfactory. Recently eccentric, but not concentric, exercises have been shown to be highly effective in managing tendinopathy of the Achilles (and other) tendons. The mechanism for the efficacy of these exercises is unknown although it has been speculated that forces generated during eccentric loading are of a greater magnitude. Our objective was to determine the mechanism for the beneficial effect of eccentric exercise in Achilles tendinopathy. Seven healthy volunteers performed eccentric and concentric loading exercises for the Achilles tendon. Tendon force and length changes were determined using a combination of motion analysis, force plate data and real-time ultrasound. There was no significant difference in peak tendon force or tendon length change when comparing eccentric with concentric exercises. However, high-frequency oscillations in tendon force occurred in all subjects during eccentric exercises but were rare in concentric exercises (P < 0.0001). These oscillations provide a mechanism to explain the therapeutic benefit of eccentric loading in Achilles tendinopathy and parallels recent evidence from bone remodelling, where the frequency of the loading cycles is of more significance than the absolute magnitude of the force.

  20. A Fibre-Reinforced Poroviscoelastic Model Accurately Describes the Biomechanical Behaviour of the Rat Achilles Tendon

    PubMed Central

    Heuijerjans, Ashley; Matikainen, Marko K.; Julkunen, Petro; Eliasson, Pernilla; Aspenberg, Per; Isaksson, Hanna

    2015-01-01

    Background Computational models of Achilles tendons can help understanding how healthy tendons are affected by repetitive loading and how the different tissue constituents contribute to the tendon’s biomechanical response. However, available models of Achilles tendon are limited in their description of the hierarchical multi-structural composition of the tissue. This study hypothesised that a poroviscoelastic fibre-reinforced model, previously successful in capturing cartilage biomechanical behaviour, can depict the biomechanical behaviour of the rat Achilles tendon found experimentally. Materials and Methods We developed a new material model of the Achilles tendon, which considers the tendon’s main constituents namely: water, proteoglycan matrix and collagen fibres. A hyperelastic formulation of the proteoglycan matrix enabled computations of large deformations of the tendon, and collagen fibres were modelled as viscoelastic. Specimen-specific finite element models were created of 9 rat Achilles tendons from an animal experiment and simulations were carried out following a repetitive tensile loading protocol. The material model parameters were calibrated against data from the rats by minimising the root mean squared error (RMS) between experimental force data and model output. Results and Conclusions All specimen models were successfully fitted to experimental data with high accuracy (RMS 0.42-1.02). Additional simulations predicted more compliant and soft tendon behaviour at reduced strain-rates compared to higher strain-rates that produce a stiff and brittle tendon response. Stress-relaxation simulations exhibited strain-dependent stress-relaxation behaviour where larger strains produced slower relaxation rates compared to smaller strain levels. Our simulations showed that the collagen fibres in the Achilles tendon are the main load-bearing component during tensile loading, where the orientation of the collagen fibres plays an important role for the tendon’s viscoelastic response. In conclusion, this model can capture the repetitive loading and unloading behaviour of intact and healthy Achilles tendons, which is a critical first step towards understanding tendon homeostasis and function as this biomechanical response changes in diseased tendons. PMID:26030436

  1. Effects of high loading by eccentric triceps surae training on Achilles tendon properties in humans.

    PubMed

    Geremia, Jeam Marcel; Baroni, Bruno Manfredini; Bobbert, Maarten Frank; Bini, Rodrigo Rico; Lanferdini, Fabio Juner; Vaz, Marco Aurélio

    2018-06-01

    To document the magnitude and time course of human Achilles tendon adaptations (i.e. changes in tendon morphological and mechanical properties) during a 12-week high-load plantar flexion training program. Ultrasound was used to determine Achilles tendon cross-sectional area (CSA), length and elongation as a function of plantar flexion torque during voluntary plantar flexion. Tendon force-elongation and stress-strain relationships were determined before the start of training (pre-training) and after 4 (post-4), 8 (post-8) and 12 (post-12) training weeks. At the end of the training program, maximum isometric force had increased by 49% and tendon CSA by 17%, but tendon length, maximal tendon elongation and maximal strain were unchanged. Hence, tendon stiffness had increased by 82%, and so had Young's modulus, by 86%. Significant changes were first detected at post-4 in stiffness (51% increase) and Young's modulus (87% increase), and at post-8 in CSA (15% increase). Achilles tendon material properties already improved after 4 weeks of high-load training: stiffness increased while CSA remained unchanged. Tendon hypertrophy (increased CSA) was observed after 8 training weeks and contributed to a further increase in Achilles tendon stiffness, but tendon stiffness increases were mostly caused by adaptations in tissue properties.

  2. The Degree of Knee Extension Does Not Affect Postoperative Stability or Subsequent Graft Tear Rate After Anterior Cruciate Ligament Reconstruction With Patellar Tendon Autograft.

    PubMed

    Benner, Rodney W; Shelbourne, K Donald; Gray, Tinker

    2016-04-01

    There is concern that high degrees of hyperextension may lead to an increase in graft laxity or graft failure after anterior cruciate ligament (ACL) reconstruction. Patients with a high degree of hyperextension will have a higher rate of graft tear/failure and lower subjective scores after surgery compared with patients with less knee extension. Cohort study, Level of evidence, 2. Of 2329 patients who underwent ACL reconstruction with patellar tendon autograft between 1998 and 2008, there were 625 patients who met the inclusion criteria of having primary ACL surgery, no bilateral ACL injuries, no existing osteoarthritis, and having either ≥6° of knee hyperextension before and after surgery (group A: n = 318; mean hyperextension, 8° ± 2° [range, 6°-15°]) or ≤3° of knee hyperextension before and after surgery (group B: n = 307; mean hyperextension, 0° ± 3° [range, 3° hyperextension to -4° short of 0° neutral]). KT-1000 arthrometer manual maximum difference between knees, range of motion measurements, and subjective follow-up with International Knee Documentation Committee (IKDC) and Cincinnati Knee Ratings Scale (CKRS) surveys were used to evaluate results. Subsequent graft tear related to specific injury within 5 years of surgery was recorded. Graft failure was defined as a KT-1000 manual maximum difference of >5 mm. Follow-up was obtained from 278 (87%) in group A and 275 (90%) in group B at a mean of 4.1 ± 1.1 years after surgery. The KT-1000 arthrometer manual maximum difference between knees was 2.0 ± 1.4 in group A and 2.1 ± 1.6 in group B (P = .701). Subsequent ACL graft tear/failure occurred in 22 patients (6.9%) in group A and 30 patients (9.8%) in group B (P = .246). Further subanalysis showed that the graft tear/failure rate was 6 of 81 (7.4%) for patients with ≥10° of hyperextension versus 16 of 237 (6.8%) for patients with 6° to 9° of hyperextension. There was no difference in IKDC or CKRS scores between groups after surgery (P = .933 and .155, respectively). Obtaining full hyperextension that is anatomically normal for most patients does not affect objective stability, ACL graft tear/failure rates, or subjective scores after ACL reconstruction with patellar tendon autograft. © 2016 The Author(s).

  3. Evidence of accumulated stress in Achilles and anterior knee tendons in elite badminton players.

    PubMed

    Boesen, Anders Ploug; Boesen, Morten Ilum; Koenig, Merete Juhl; Bliddal, Henning; Torp-Pedersen, Soren; Langberg, Henning

    2011-01-01

    Tendon-related injuries are a major problem, but the aetiology of tendinopathies is unknown. In tendinopathies as well as during unaccustomed loading, intra-tendinous flow can be detected indicating that extensive loading can provoke intra-tendinous flow. The aim of present study is to evaluate the vascular response as indicated by colour Doppler (CD) activity in both the Achilles and patella tendon after loading during high-level badminton matches. The Achilles tendon was subdivided into a mid-tendon, pre-insertional, and insertional region and the anterior knee tendons into a quadriceps-, patella- and tuberositas region. Intra-tendinous flow was measured using both a semi-quantitative grading system (CD grading) and a quantitative scoring system (CF) on colour Doppler. Intra-tendinous flow in the Achilles and anterior knee tendons was examined in fourteen single players before tournament and after 1st and 2nd match, respectively on both the dominant and non-dominant side. All players had abnormal intra-tendinous flow (Colour Doppler ≥ grade 2) in at least one tendon in at least one scan during the tournament. At baseline, only two of the 14 players had normal flow in all the tendons examined. After 1st match, tendencies to higher intra-tendinous flow were observed in both the dominant patella tendon and non-dominant quadriceps tendon (P-values n.s.). After 2nd match, intra-tendinous flow was significant increased in the dominant patella tendon (P = 0.009). In all other locations, there was a trend towards a stepwise increase in intra-tendinous flow. The preliminary results indicate that high amount of intra-tendinous flow was found in elite badminton players at baseline and was increased after repetitive loading, especially in the patella tendon (dominant leg). The colour Doppler measurement can be used to determine changes in intra-tendinous flow after repetitive loading.

  4. Effects of Heavy Strength Training on Running Performance and Determinants of Running Performance in Female Endurance Athletes

    PubMed Central

    Vikmoen, Olav; Raastad, Truls; Seynnes, Olivier; Bergstrøm, Kristoffer; Ellefsen, Stian; Rønnestad, Bent R.

    2016-01-01

    Purpose The purpose of the current study was to investigate the effects of adding strength training to normal endurance training on running performance and running economy in well-trained female athletes. We hypothesized that the added strength training would improve performance and running economy through altered stiffness of the muscle-tendon complex of leg extensors. Methods Nineteen female endurance athletes [maximal oxygen consumption (VO2max): 53±3 ml∙kg-1∙min-1, 5.8 h weekly endurance training] were randomly assigned to either normal endurance training (E, n = 8) or normal endurance training combined with strength training (E+S, n = 11). The strength training consisted of four leg exercises [3 x 4–10 repetition maximum (RM)], twice a week for 11 weeks. Muscle strength, 40 min all-out running distance, running performance determinants and patellar tendon stiffness were measured before and after the intervention. Results E+S increased 1RM in leg exercises (40 ± 15%) and maximal jumping height in counter movement jump (6 ± 6%) and squat jump (9 ± 7%, p < 0.05). This was accompanied by increased muscle fiber cross sectional area of both fiber type I (13 ± 7%) and fiber type II (31 ± 20%) in m. vastus lateralis (p < 0.05), with no change in capillary density in m. vastus lateralis or the stiffness of the patellar tendon. Neither E+S nor E changed running economy, fractional utilization of VO2max or VO2max. There were also no change in running distance during a 40 min all-out running test in neither of the groups. Conclusion Adding heavy strength training to endurance training did not affect 40 min all-out running performance or running economy compared to endurance training only. PMID:26953893

  5. Mechanical loading stimulates ecto-ATPase activity in human tendon cells.

    PubMed

    Tsuzaki, M; Bynum, D; Almekinders, L; Faber, J; Banes, A J

    2005-09-01

    Response to external stimuli such as mechanical signals is critical for normal function of cells, especially when subjected to repetitive motion. Tenocytes receive mechanical stimuli from the load-bearing matrix as tension, compression, and shear stress during tendon gliding. Overloading a tendon by high strain, shear, or repetitive motion can cause matrix damage. Injury may induce cytokine expression, matrix metalloproteinase (MMP) expression and activation resulting in loss of biomechanical properties. These changes may result in tendinosis or tendinopathy. Alternatively, an immediate effector molecule may exist that acts in a signal-dampening pathway. Adenosine 5'-triphosphate (ATP) is a candidate signal blocker of mechanical stimuli. ATP suppresses load-inducible inflammatory genes in human tendon cells in vitro. ATP and other extracellular nucleotide signaling are regulated efficiently by two distinct mechanisms: purinoceptors via specific receptor-ligand binding and ecto-nucleotidases via the hydrolysis of specific nucleotide substrates. ATP is released from tendon cells by mechanical loading or by uridine 5'-triphosphate (UTP) stimulation. We hypothesized that mechanical loading might stimulate ecto-ATPase activity. Human tendon cells of surface epitenon (TSC) and internal compartment (TIF) were cyclically stretched (1 Hz, 0.035 strain, 2 h) with or without ATP. Aliquots of the supernatant fluids were collected at various time points, and ATP concentration (ATP) was determined by a luciferin-luciferase bioluminescence assay. Total RNA was isolated from TSC and TIF (three patients) and mRNA expression for ecto-nucleotidase was analyzed by RT-PCR. Human tendon cells secreted ATP in vitro (0.5-1 nM). Exogenous ATP was hydrolyzed within minutes. Mechanical load stimulated ATPase activity. ATP was hydrolyzed in mechanically loaded cultures at a significantly greater rate compared to no load controls. Tenocytes (TSC and TIF) expressed ecto-nucleotidase mRNA (ENTPD3 and ENPP1, ENPP2). These data suggest that motion may release ATP from tendon cells in vivo, where ecto-ATPase may also be activated to hydrolyze ATP quickly. Ecto-ATPase may act as a co-modulator in ATP load-signal modulation by regulating the half-life of extracellular purine nucleotides. The extracellular ATP/ATPase system may be important for tendon homeostasis by protecting tendon cells from responding to excessive load signals and activating injurious pathways. Copyright 2005 Wiley-Liss, Inc

  6. Coordinated collagen and muscle protein synthesis in human patella tendon and quadriceps muscle after exercise

    PubMed Central

    Miller, Benjamin F; Olesen, Jens L; Hansen, Mette; Døssing, Simon; Crameri, Regina M; Welling, Rasmus J; Langberg, Henning; Flyvbjerg, Allan; Kjaer, Michael; Babraj, John A; Smith, Kenneth; Rennie, Michael J

    2005-01-01

    We hypothesized that an acute bout of strenuous, non-damaging exercise would increase rates of protein synthesis of collagen in tendon and skeletal muscle but these would be less than those of muscle myofibrillar and sarcoplasmic proteins. Two groups (n = 8 and 6) of healthy young men were studied over 72 h after 1 h of one-legged kicking exercise at 67% of maximum workload (Wmax). To label tissue proteins in muscle and tendon primed, constant infusions of [1-13C]leucine or [1-13C]valine and flooding doses of [15N] or [13C]proline were given intravenously, with estimation of labelling in target proteins by gas chromatography–mass spectrometry. Patellar tendon and quadriceps biopsies were taken in exercised and rested legs at 6, 24, 42 or 48 and 72 h after exercise. The fractional synthetic rates of all proteins were elevated at 6 h and rose rapidly to peak at 24 h post exercise (tendon collagen (0.077% h−1), muscle collagen (0.054% h−1), myofibrillar protein (0.121% h−1), and sarcoplasmic protein (0.134% h−1)). The rates decreased toward basal values by 72 h although rates of tendon collagen and myofibrillar protein synthesis remained elevated. There was no tissue damage of muscle visible on histological evaluation. Neither tissue microdialysate nor serum concentrations of IGF-I and IGF binding proteins (IGFBP-3 and IGFBP-4) or procollagen type I N-terminal propeptide changed from resting values. Thus, there is a rapid increase in collagen synthesis after strenuous exercise in human tendon and muscle. The similar time course of changes of protein synthetic rates in different cell types supports the idea of coordinated musculotendinous adaptation. PMID:16002437

  7. A Load-Sharing Rip-Stop Fixation Construct for Arthroscopic Rotator Cuff Repair

    PubMed Central

    Denard, Patrick J.; Burkhart, Stephen S.

    2012-01-01

    Despite advancements in arthroscopic rotator cuff repair techniques, achieving tendon-to-bone healing can be difficult in the setting of poor-quality tendon. Moreover, medial tendon tears or tears with lateral tendon loss may preclude standard techniques. Rip-stop suture configurations have been shown to improve load to failure compared with simple or mattress stitch patterns and may be particularly valuable in these settings. The purpose of this report is to describe a technical modification of a rip-stop rotator cuff repair that combines the advantages of a rip-stop suture (by providing resistance to tissue cutout) and a double row of load-sharing suture anchors (minimizing the load per anchor and therefore the load per suture within each anchor). PMID:23766972

  8. Moderate Exercise Mitigates the Detrimental Effects of Aging on Tendon Stem Cells.

    PubMed

    Zhang, Jianying; Wang, James H-C

    2015-01-01

    Aging is known to cause tendon degeneration whereas moderate exercise imparts beneficial effects on tendons. Since stem cells play a vital role in maintaining tissue integrity, in this study we aimed to define the effects of aging and moderate exercise on tendon stem/progenitor cells (TSCs) using in vitro and in vivo models. TSCs derived from aging mice (9 and 24 months) proliferated significantly slower than TSCs obtained from young mice (2.5 and 5 months). In addition, expression of the stem cell markers Oct-4, nucleostemin (NS), Sca-1 and SSEA-1 in TSCs decreased in an age-dependent manner. Interestingly, moderate mechanical stretching (4%) of aging TSCs in vitro significantly increased the expression of the stem cell marker, NS, but 8% stretching decreased NS expression. Similarly, 4% mechanical stretching increased the expression of Nanog, another stem cell marker, and the tenocyte-related genes, collagen I and tenomodulin. However, 8% stretching increased expression of the non-tenocyte-related genes, LPL, Sox-9 and Runx-2, while 4% stretching had minimal effects on the expression of these genes. In the in vivo study, moderate treadmill running (MTR) of aging mice (9 months) resulted in the increased proliferation rate of aging TSCs in culture, decreased lipid deposition, proteoglycan accumulation and calcification, and increased the expression of NS in the patellar tendons. These findings indicate that while aging impairs the proliferative ability of TSCs and reduces their stemness, moderate exercise can mitigate the deleterious effects of aging on TSCs and therefore may be responsible for decreased aging-induced tendon degeneration.

  9. Concurrent prediction of muscle and tibiofemoral contact forces during treadmill gait.

    PubMed

    Guess, Trent M; Stylianou, Antonis P; Kia, Mohammad

    2014-02-01

    Detailed knowledge of knee kinematics and dynamic loading is essential for improving the design and outcomes of surgical procedures, tissue engineering applications, prosthetics design, and rehabilitation. This study used publicly available data provided by the "Grand Challenge Competition to Predict in-vivo Knee Loads" for the 2013 American Society of Mechanical Engineers Summer Bioengineering Conference (Fregly et al., 2012, "Grand Challenge Competition to Predict in vivo Knee Loads," J. Orthop. Res., 30, pp. 503-513) to develop a full body, musculoskeletal model with subject specific right leg geometries that can concurrently predict muscle forces, ligament forces, and knee and ground contact forces. The model includes representation of foot/floor interactions and predicted tibiofemoral joint loads were compared to measured tibial loads for two different cycles of treadmill gait. The model used anthropometric data (height and weight) to scale the joint center locations and mass properties of a generic model and then used subject bone geometries to more accurately position the hip and ankle. The musculoskeletal model included 44 muscles on the right leg, and subject specific geometries were used to create a 12 degrees-of-freedom anatomical right knee that included both patellofemoral and tibiofemoral articulations. Tibiofemoral motion was constrained by deformable contacts defined between the tibial insert and femoral component geometries and by ligaments. Patellofemoral motion was constrained by contact between the patellar button and femoral component geometries and the patellar tendon. Shoe geometries were added to the feet, and shoe motion was constrained by contact between three shoe segments per foot and the treadmill surface. Six-axis springs constrained motion between the feet and shoe segments. Experimental motion capture data provided input to an inverse kinematics stage, and the final forward dynamics simulations tracked joint angle errors for the left leg and upper body and tracked muscle length errors for the right leg. The one cycle RMS errors between the predicted and measured tibia contact were 178 N and 168 N for the medial and lateral sides for the first gait cycle and 209 N and 228 N for the medial and lateral sides for the faster second gait cycle. One cycle RMS errors between predicted and measured ground reaction forces were 12 N, 13 N, and 65 N in the anterior-posterior, medial-lateral, and vertical directions for the first gait cycle and 43 N, 15 N, and 96 N in the anterior-posterior, medial-lateral, and vertical directions for the second gait cycle.

  10. Quantification of Internal Stress-Strain Fields in Human Tendon: Unraveling the Mechanisms that Underlie Regional Tendon Adaptations and Mal-Adaptations to Mechanical Loading and the Effectiveness of Therapeutic Eccentric Exercise

    PubMed Central

    Maganaris, Constantinos N.; Chatzistergos, Panagiotis; Reeves, Neil D.; Narici, Marco V.

    2017-01-01

    By virtue of their anatomical location between muscles and bones, tendons make it possible to transform contractile force to joint rotation and locomotion. However, tendons do not behave as rigid links, but exhibit viscoelastic tensile properties, thereby affecting the length and contractile force in the in-series muscle, but also storing and releasing elastic stain energy as some tendons are stretched and recoiled in a cyclic manner during locomotion. In the late 90s, advancements were made in the application of ultrasound scanning that allowed quantifying the tensile deformability and mechanical properties of human tendons in vivo. Since then, the main principles of the ultrasound-based method have been applied by numerous research groups throughout the world and showed that tendons increase their tensile stiffness in response to exercise training and chronic mechanical loading, in general, by increasing their size and improving their intrinsic material. It is often assumed that these changes occur homogenously, in the entire body of the tendon, but recent findings indicate that the adaptations may in fact take place in some but not all tendon regions. The present review focuses on these regional adaptability features and highlights two paradigms where they are particularly evident: (a) Chronic mechanical loading in healthy tendons, and (b) tendinopathy. In the former loading paradigm, local tendon adaptations indicate that certain regions may “see,” and therefore adapt to, increased levels of stress. In the latter paradigm, local pathological features indicate that certain tendon regions may be “stress-shielded” and degenerate over time. Eccentric exercise protocols have successfully been used in the management of tendinopathy, without much sound understanding of the mechanisms underpinning their effectiveness. For insertional tendinopathy, in particular, it is possible that the effectiveness of a loading/rehabilitation protocol depends on the topography of the stress created by the exercise and is not only reliant upon the type of muscle contraction performed. To better understand the micromechanical behavior and regional adaptability/mal-adaptability of tendon tissue it is important to estimate its internal stress-strain fields. Recent relevant advancements in numerical techniques related to tendon loading are discussed. PMID:28293194

  11. Collagen fibrils in functionally distinct tendons have differing structural responses to tendon rupture and fatigue loading.

    PubMed

    Herod, Tyler W; Chambers, Neil C; Veres, Samuel P

    2016-09-15

    In this study we investigate relationships between the nanoscale structure of collagen fibrils and the macroscale functional response of collagenous tissues. To do so, we study two functionally distinct classes of tendons, positional tendons and energy storing tendons, using a bovine forelimb model. Molecular-level assessment using differential scanning calorimetry (DSC), functional crosslink assessment using hydrothermal isometric tension (HIT) analysis, and ultrastructural assessment using scanning electron microscopy (SEM) were used to study undamaged, ruptured, and cyclically loaded samples from the two tendon types. HIT indicated differences in both crosslink type and crosslink density, with flexor tendons having more thermally stable crosslinks than the extensor tendons (higher TFmax of >90 vs. 75.1±2.7°C), and greater total crosslink density than the extensor tendons (higher t1/2 of 11.5±1.9 vs. 3.5±1.0h after NaBH4 treatment). Despite having a lower crosslink density than flexor tendons, extensor tendons were significantly stronger (37.6±8.1 vs. 23.1±7.7MPa) and tougher (14.3±3.6 vs. 6.8±3.4MJ/m(3)). SEM showed that collagen fibrils in the tougher, stronger extensor tendons were able to undergo remarkable levels of plastic deformation in the form of discrete plasticity, while those in the flexor tendons were not able to plastically deform. When cyclically loaded, collagen fibrils in extensor tendons accumulated fatigue damage rapidly in the form of kink bands, while those in flexor tendons did not accumulate significant fatigue damage. The results demonstrate that collagen fibrils in functionally distinct tendons respond differently to mechanical loading, and suggests that fibrillar collagens may be subject to a strength vs. fatigue resistance tradeoff. Collagen fibrils-nanoscale biological cables-are the fundamental load-bearing elements of all structural human tissues. While all collagen fibrils share common features, such as being composed of a precise quarter-staggered polymeric arrangement of triple-helical collagen molecules, their structure can vary significantly between tissue types, and even between different anatomical structures of the same tissue type. To understand normal function, homeostasis, and disease of collagenous tissues requires detailed knowledge of collagen fibril structure-function. Using anatomically proximate but structurally distinct tendons, we show that collagen fibrils in functionally distinct tendons have differing susceptibilities to damage under both tensile overload and cyclic fatigue loading. Our results suggest that the structure of collagen fibrils may lead to a strength versus fatigue resistance tradeoff, where high strength is gained at the expense of fatigue resistance, and vice versa. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  12. Eccentric exercises; why do they work, what are the problems and how can we improve them?

    PubMed

    Rees, J D; Wolman, R L; Wilson, A

    2009-04-01

    Eccentric exercises (EE) have proved successful in the management of chronic tendinopathy, particularly of the Achilles and patellar tendons, where they have been shown to be effective in controlled trials. However, numerous questions regarding EE remain. The standard protocols are time-consuming and require very motivated patients. EE are effective in some tendinopathies but not others. Furthermore, the location of the lesion can have a profound effect on efficacy; for example, standard EE in insertional lesions of the Achilles are ineffective. Until recently little was known of the effect of EE on tendinopathic tendons, although a greater understanding of this process is emerging. Additionally, recent in vivo evidence directly comparing eccentric and concentric exercises provides a possible explanation for the therapeutic benefit of EE. The challenge now is to make EE more effective. Suggestions on areas of future research are made.

  13. Micromechanical modeling of rate-dependent behavior of Connective tissues.

    PubMed

    Fallah, A; Ahmadian, M T; Firozbakhsh, K; Aghdam, M M

    2017-03-07

    In this paper, a constitutive and micromechanical model for prediction of rate-dependent behavior of connective tissues (CTs) is presented. Connective tissues are considered as nonlinear viscoelastic material. The rate-dependent behavior of CTs is incorporated into model using the well-known quasi-linear viscoelasticity (QLV) theory. A planar wavy representative volume element (RVE) is considered based on the tissue microstructure histological evidences. The presented model parameters are identified based on the available experiments in the literature. The presented constitutive model introduced to ABAQUS by means of UMAT subroutine. Results show that, monotonic uniaxial test predictions of the presented model at different strain rates for rat tail tendon (RTT) and human patellar tendon (HPT) are in good agreement with experimental data. Results of incremental stress-relaxation test are also presented to investigate both instantaneous and viscoelastic behavior of connective tissues. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Treatment of recurrent patellar dislocation via knee arthroscopy combined with C-arm fluoroscopy and reconstruction of the medial patellofemoral ligament.

    PubMed

    Li, Li; Wang, Hongbo; He, Yun; Si, Yu; Zhou, Hongyu; Wang, Xin

    2018-06-01

    Recurrent patellar dislocations were treated via knee arthroscopy combined with C-arm fluoroscopy, and reconstruction of the medial patellofemoral ligaments. Between October 2013 and March 2017, 52 cases of recurrent patellar dislocation [27 males and 25 females; age, 16-47 years (mean, 21.90 years)] were treated. Arthroscopic exploration was performed and patellofemoral joint cartilage injuries were repaired. It was subsequently determined whether it was necessary to release the lateral patellofemoral support belt. Pre-operative measurements were used to decide whether tibial tubercle osteotomy was required. Medial patellofemoral ligaments were reconstructed using autologous semitendinosus tendons. Smith and Nephew model 3.5 line anchors were used to double-anchor the medial patellofemoral margin. On the femoral side, the medial patellofemoral ligament was fixed using 7-cm, absorbable, interfacial compression screws. All cases were followed for 1-40 months (average, 21 months). The Q angle, tibial tuberosity trochlear groove distance, Insall-Salvati index, patellofemoral angle, lateral patellofemoral angle and lateral shift were evaluated on X-Ray images using the picture archiving and communication system. Subjective International Knee Documentation Committee (IKDC) knee joint functional scores and Lysholm scores were recorded. Post-operative fear was absent, and no patellar re-dislocation or re-fracture was noted during follow-up. At the end of follow-up, the patellofemoral angle (0.22±4.23°), lateral patellofemoral angle (3.44±1.30°), and lateral shift (0.36+0.14°) differed significantly from the pre-operative values (all, P<0.05). Furthermore, IKDC and Lysholm scores (87.84+3.74 and 87.48+3.35, respectively) differed significantly from the pre-operative values (both, P<0.05). These findings suggest that, in the short term, recurrent patellar dislocation treatment via knee arthroscopy combined with C-arm fluoroscopy and reconstruction of the medial patellofemoral ligament was effective.

  15. Leg stiffness, valgus knee motion, and Q-angle are associated with hypertrophic soft patella tendon and idiopathic knee pain in adolescent basketball players.

    PubMed

    Satkunskiene, Danguole; Mickevicius, Mantas; Snieckus, Audrius; Kamandulis, Sigitas

    2017-01-01

    Knee pain without knee degenerative symptoms is a common phenomenon among young basketball players. The aim of this study was to identify factors predisposing young basketball players to suffer from knee pain. The study involved 20 male adolescent (14-15 years) basketball players who were divided into two equal groups based on knee pain symptoms. Legs torque was tested on an isokinetic dynamometer. The length, elongation and the cross-sectional area (CSA) of the patellar tendon were measured with ultrasonography. Quadriceps angle (Q-angle), knee valgus motion, and joint angular displacement in the sagittal plane were analyzed using video recording during countermovement jump. Ground reaction force was measured using a force platform. Knee pain (KP) participants had a significantly lower Q-angle (P=0.045) and lower maximum varus knee angle (P=0.035), and a greater knee inside displacement (P=0.039) during squat phase. In the KP group, the CSA at the top of the tendon was significantly greater than in the middle (P=0.006) and at the bottom (P=0.039). Absolute tendon stiffness (P=0.013) and Young's modulus (P=0.034) were significantly lower in the KP group compared with controls. Leg stiffness during landing was significantly greater in the control group (P=0.015). Leg stiffness, valgus knee motion, and Q-angle are associated with hypertrophic soft patella tendon and idiopathic knee pain in adolescent basketball players.

  16. Human tendon behaviour and adaptation, in vivo

    PubMed Central

    Magnusson, S Peter; Narici, Marco V; Maganaris, Constantinos N; Kjaer, Michael

    2008-01-01

    Tendon properties contribute to the complex interaction of the central nervous system, muscle–tendon unit and bony structures to produce joint movement. Until recently limited information on human tendon behaviour in vivo was available; however, novel methodological advancements have enabled new insights to be gained in this area. The present review summarizes the progress made with respect to human tendon and aponeurosis function in vivo, and how tendons adapt to ageing, loading and unloading conditions. During low tensile loading or with passive lengthening not only the muscle is elongated, but also the tendon undergoes significant length changes, which may have implications for reflex responses. During active loading, the length change of the tendon far exceeds that of the aponeurosis, indicating that the aponeurosis may more effectively transfer force onto the tendon, which lengthens and stores elastic energy subsequently released during unloading, in a spring-like manner. In fact, data recently obtained in vivo confirm that, during walking, the human Achilles tendon provides elastic strain energy that can decrease the energy cost of locomotion. Also, new experimental evidence shows that, contrary to earlier beliefs, the metabolic activity in human tendon is remarkably high and this affords the tendon the ability to adapt to changing demands. With ageing and disuse there is a reduction in tendon stiffness, which can be mitigated with resistance exercises. Such adaptations seem advantageous for maintaining movement rapidity, reducing tendon stress and risk of injury, and possibly, for enabling muscles to operate closer to the optimum region of the length–tension relationship. PMID:17855761

  17. The influence of freezing on the tensile strength of tendon grafts : a biomechanical study.

    PubMed

    Arnout, Nele; Myncke, Jan; Vanlauwe, Johan; Labey, Luc; Lismont, Daniel; Bellemans, Johan

    2013-08-01

    We investigated the influence of freezing on the tensile strength of fresh frozen tendon grafts. The biomechanical characteristics of tendons that are less commonly used in knee surgery (tibialis anterior, tibialis posterior, peroneus longus and medial and lateral half of Achilles tendons) were compared to those of a semitendinosus and gracilis graft harvested from the same 10 multi-organ donors. All right side tendons constituted the study group and were frozen at -80 degrees C and thawed at room temperature 5 times. All left side tendons were frozen at -80 degrees C and thawed at room temperature once. There were 59 tendons in the control group and 56 in the study group. The looped grafts were clamped at one side using a custom-made freeze clamp and loaded until failure on an Instron 4505 testing machine. The average ultimate failure load was not significantly different between the control and the study group (p > 0.05). The failure load of the medial tendon Achilles was the lowest in both study and control group (p < 0.001). There was no significant difference in maximum stress, maximum displacement, maximum strain and stiffness between the control and study group (p > 0.05). From our study, we conclude that freezing tendons at -80 degrees C and thawing several times does not influence the maximum load, maximum stress, maximum displacement, maximum strain and stiffness. The medial half of the Achilles tendon is clearly the weakest tendon (p < 0.001). These findings show that tendon grafts can be frozen at -80 degrees C and thawed at room temperature several times without altering their biomechanical properties.

  18. Triple-loaded single-anchor stitch configurations: an analysis of cyclically loaded suture-tendon interface security.

    PubMed

    Coons, David A; Barber, F Alan; Herbert, Morley A

    2006-11-01

    This study evaluated the strength and suture-tendon interface security of different suture configurations from triple-suture-loaded anchors. A juvenile bovine infraspinatus tendon was detached and repaired by use of 4 different suture combinations from 2 suture anchors: 3 simple sutures in each anchor (ThreeVo anchor; Linvatec, Largo, FL); 2 peripheral simple stitches and 1 central horizontal mattress suture passed deeper into the tendon, creating a larger footprint (bigfoot-print anchor); 2 peripheral simple stitches with 1 central horizontal mattress stitch passed through the same holes as the simple sutures (stitch-of-Burns); and 2 simple stitches (TwoVo anchor; Linvatec). The constructs were cyclically loaded between 10 N and 180 N for 3,500 cycles and then destructively tested. The number of cycles required to create a 5-mm gap and a 10-mm gap and the ultimate load to failure and failure mode were recorded. The ThreeVo anchor was strongest and most resistant to cyclic loading (P < .01). The TwoVo anchor was least resistant to cyclic loading. The stitch-of-Burns anchor was more resistant to cyclic loading than both the bigfoot-print anchor and the TwoVo anchor (P < .03). The ThreeVo, stitch-of-Burns, and TwoVo anchors were stronger than the bigfoot-print anchor (P < .05). Three simple sutures in an anchor hold better than two simple sutures. Three simple sutures provide superior suture-tendon security than combinations of one mattress and two simple stitches subjected to cyclic loading. A central mattress stitch placed more medially than two peripheral simple stitches (bigfoot-print anchor) configured to enlarge the tendon-suture footprint was not as resistant to cyclic loading or destructive testing as three simple stitches (ThreeVo anchor). Placing a central mattress stitch more medially than 2 peripheral simple stitches to enlarge the tendon-suture footprint was not as resistant to cyclic loading or destructive testing as 3 simple stitches.

  19. Biomechanical Cadaveric Evaluation of Partial Acute Peroneal Tendon Tears.

    PubMed

    Wagner, Emilio; Wagner, Pablo; Ortiz, Cristian; Radkievich, Ruben; Palma, Felipe; Guzmán-Venegas, Rodrigo

    2018-06-01

    No clear guideline or solid evidence exists for peroneal tendon tears to determine when to repair, resect, or perform a tenodesis on the damaged tendon. The objective of this study was to analyze the mechanical behavior of cadaveric peroneal tendons artificially damaged and tested in a cyclic and failure mode. The hypothesis was that no failure would be observed in the cyclic phase. Eight cadaveric long leg specimens were tested on a specially designed frame. A longitudinal full thickness tendon defect was created, 3 cm in length, behind the tip of the fibula, compromising 66% of the visible width of the peroneal tendons. Cyclic testing was initially performed between 50 and 200 N, followed by a load-to-failure test. Tendon elongation and load to rupture were measured. No tendon failed or lengthened during cyclic testing. The mean load to failure for peroneus brevis was 416 N (95% confidence interval, 351-481 N) and for the peroneus longus was 723 N (95% confidence interval, 578-868 N). All failures were at the level of the defect created. In a cadaveric model of peroneal tendon tears, 33% of remaining peroneal tendon could resist high tensile forces, above the physiologic threshold. Some peroneal tendon tears can be treated conservatively without risking spontaneous ruptures. When surgically treating a symptomatic peroneal tendon tear, increased efforts may be undertaken to repair tears previously considered irreparable.

  20. Structural changes in loaded equine tendons can be monitored by a novel spectroscopic technique

    PubMed Central

    Kostyuk, Oksana; Birch, Helen L; Mudera, Vivek; Brown, Robert A

    2004-01-01

    This study aimed to investigate the preferential collagen fibril alignment in unloaded and loaded tendons using elastic scattering spectroscopy. The device consisted of an optical probe, a pulsed light source (320–860 nm), a spectrometer and a PC. Two probes with either 2.75 mm or 300 μm source-detector separations were used to monitor deep and superficial layers, respectively. Equine superficial digital flexor tendons were subjected to ex vivo progressive tensional loading. Seven times more backscattered light was detected parallel rather than perpendicular to the tendon axis with the 2.75 mm separation probe in unloaded tendons. In contrast, using the 300 μm separation probe the plane of maximum backscatter (3-fold greater) was perpendicular to the tendon axis. There was no optical anisotropy in the cross-sectional plane of the tendon (i.e. the transversely cut tendon surface), with no structural anisotropy. During mechanical loading (9–14% strain) backscatter anisotropy increased 8.5- to 18.5-fold along the principal strain axis for 2.75 mm probe separation, but almost disappeared in the perpendicular plane (measured using the 300 μm probe separation). Optical (anisotropy) and mechanical (strain) measurements were highly correlated. We conclude that spatial anisotropy of backscattered light can be used for quantitative monitoring of collagen fibril alignment and tissue reorganization during loading, with the potential for minimally invasive real-time structural monitoring of fibrous tissues in normal, pathological or repairing tissues and in tissue engineering. PMID:14578479

  1. Comparison of superficial digital flexor tendon loading on asphalt and sand in horses at the walk and trot.

    PubMed

    Crevier-Denoix, N; Ravary-Plumioën, B; Vergari, C; Camus, M; Holden-Douilly, L; Falala, S; Jerbi, H; Desquilbet, L; Chateau, H; Denoix, J-M; Pourcelot, P

    2013-12-01

    The incidence of superficial digital flexor tendon (SDFT) injuries is one of the highest of all equine musculoskeletal conditions. Horses with SDFT injuries commonly show no improvement of lameness on soft ground, unlike those suffering from distal bone or joint lesions. The aim of this study was to compare the SDFT loading in five horses at the walk and trot on asphalt and sand using a non-invasive ultrasonic tendon force measurement device. Three horses were equipped with the ultrasonic device, whereas the other two horses were equipped with the ultrasonic device and a dynamometric horseshoe (DHS); the DHS was used to calibrate the measured values of tendon speed of sound (SOS) converted to tendon force, while a previously established ground reaction force pattern was used to calibrate SOS measurements for the other three horses. Although the horses tended to be slower on S, maximal tendon force was higher on sand than on asphalt at the trot (+6%); there was no significant difference between the two surfaces at the walk. The duration of tendon loading was longer on S (+5%) and the area under the tendon force-time curve was larger on S (+10%) at both walk and trot. SDFT loading is significantly affected by the ground surface and the observed increase in SDFT loading on sand compared with asphalt is consistent with clinical observations in horses with SDFT injuries. Copyright © 2013. Published by Elsevier Ltd.

  2. Is quadriceps tendon a better graft choice than patellar tendon? a prospective randomized study.

    PubMed

    Lund, Bent; Nielsen, Torsten; Faunø, Peter; Christiansen, Svend Erik; Lind, Martin

    2014-05-01

    The purpose of this randomized controlled study was to compare knee stability, kneeling pain, harvest site pain, sensitivity loss, and subjective clinical outcome after primary anterior cruciate ligament (ACL) reconstruction with either bone-patellar tendon-bone (BPTB) or quadriceps tendon-bone (QTB) autografts in a noninferiority study design. From 2005 to 2009, a total of 51 patients were included in the present study. Inclusion criteria were isolated ACL injuries in adults. Twenty-five patients were randomized to BPTB grafts and 26 to QTB grafts. An independent examiner performed follow-up evaluations 1 and 2 years postoperatively. Anteroposterior knee laxity was measured with a KT-1000 arthrometer (MEDmetric, San Diego, CA). Anterior knee pain was assessed clinically and by knee-walking ability. Knee Injury and Osteoarthritis Outcome Score (KOOS) and subjective International Knee Documentation Committee (IKDC) score were used for patient-evaluated outcome. Anterior knee laxity was equal between the 2 groups with KT-1000 values of 1.1 ± 1.4 mm and 0.8 ± 1.7 mm standard deviation (SD) at follow-up in QTB and BPTB groups, respectively (P = .65), whereas positive pivot shift test results were seen less frequently (14% compared with 38%, respectively; P = .03). Anterior kneeling pain, evaluated by the knee walking ability test, was significantly less in the QTB group, with only 7% of patients grading knee walking as difficult or impossible compared with 34% in the BPTB group. At 1 and 2 years' follow-up, there was no difference between the 2 groups in subjective patient-evaluated outcome. The IKDC score was 75 ± 13 patients and 76 ± 16 SD at 1-year follow-up in QTB and BPTB groups, respectively (P = .78). At 2 years, 12 patients were lost to follow-up, resulting in 18 in the BPTB group and 21 in the QTB group. The use of the QTB graft results in less kneeling pain, graft site pain, and sensitivity loss than seen with BPTB grafts; however, similar anterior knee stability and subjective outcomes are seen. The results of this study show that QTB is a viable option for ACL reconstruction. Level II, randomized controlled clinical trial. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  3. The surgical anatomy of the infrapatellar branch of the saphenous nerve in relation to incisions for anteromedial knee surgery.

    PubMed

    Kerver, A L A; Leliveld, M S; den Hartog, D; Verhofstad, M H J; Kleinrensink, G J

    2013-12-04

    Iatrogenic injury to the infrapatellar branch of the saphenous nerve is a common complication of surgical approaches to the anteromedial side of the knee. A detailed description of the relative anatomic course of the nerve is important to define clinical guidelines and minimize iatrogenic damage during anterior knee surgery. In twenty embalmed knees, the infrapatellar branch of the saphenous nerve was dissected. With use of a computer-assisted surgical anatomy mapping tool, safe and risk zones, as well as the location-dependent direction of the nerve, were calculated. The location of the infrapatellar branch of the saphenous nerve is highly variable, and no definite safe zone could be identified. The infrapatellar branch runs in neither a purely horizontal nor a vertical course. The course of the branch is location-dependent. Medially, it runs a nearly vertical course; medial to the patellar tendon, it has a -45° distal-lateral course; and on the patella and patellar tendon, it runs a close to horizontal-lateral course. Three low risk zones for iatrogenic nerve injury were identified: one is on the medial side of the knee, at the level of the tibial tuberosity, where a -45° oblique incision is least prone to damage the nerves, and two zones are located medial to the patellar apex (cranial and caudal), where close to horizontal incisions are least prone to damage the nerves. The infrapatellar branch of the saphenous nerve is at risk for iatrogenic damage in anteromedial knee surgery, especially when longitudinal incisions are made. There are three low risk zones for a safer anterior approach to the knee. The direction of the infrapatellar branch of the saphenous nerve is location-dependent. To minimize iatrogenic damage to the nerve, the direction of incisions should be parallel to the direction of the nerve when technically possible. These findings suggest that iatrogenic damage of the infrapatellar branch of the saphenous nerve can be minimized in anteromedial knee surgery when both the location and the location-dependent direction of the nerve are considered when making the skin incision.

  4. Pitfalls during biomechanical testing - Evaluation of different fixation methods for measuring tendons endurance properties.

    PubMed

    Hangody, Gy; Pánics, G; Szebényi, G; Kiss, R; Hangody, L; Pap, K

    2016-03-01

    The goal of the study was to find a proper technique to fix tendon grafts into an INSTRON loading machine. From 8 human cadavers, 40 grafts were collected. We removed the bone-patella tendon-bone grafts, the semitendinosus and gracilis tendons, the quadriceps tendon-bone grafts, the Achilles tendons, and the peroneus longus tendons from each lower extremity. We tested the tendon grafts with five different types of fixation devices: surgical thread (Premicron 3), general mounting clamp, wire mesh, cement fixation, and a modified clamp for an INSTRON loading machine. The mean failure load in case of surgical thread fixation was (381N ± 26N). The results with the general clamp were (527N ± 45N). The wire meshes were more promising (750N ± 21N), but did not reach the outcomes we desired. Easy slippages of the ends of the tendons from the cement encasements were observed (253N ± 18N). We then began to use Shi's clamp that could produce 977N ± 416N peak force. We combined Shi's clamp with freezing of the graft and the rupture of the tendon itself demonstrated an average force of 2198 N ± 773N. We determined that our modified frozen clamp fixed the specimens against high tensile forces.

  5. Acute tendon changes in intense CrossFit workout: an observational cohort study.

    PubMed

    Fisker, F Y; Kildegaard, S; Thygesen, M; Grosen, K; Pfeiffer-Jensen, M

    2017-11-01

    CrossFit is a fitness program that has become increasingly popular in the Western world, but as in other sports, the risk of injury is present. Only a few studies have addressed health benefits and injuries in CrossFit. It is known that chronically overloaded tendons will thicken and increase the risk of tendinopathy. However, it remains unknown whether acute overload caused by strenuous, high-intensity exercise will exert changes in tendons and if these changes can be detected and described by ultrasonography. The aim of this study is to evaluate the effects of acute overload on tendon thickness using ultrasonography. Standardized ultrasound measurements of the patella, Achilles, and plantaris tendons were performed before and after a specific workout in 34 healthy subjects. Significant increases were observed in patella tendon thickness before (M = 4.5, SD = 0.6) and after (M = 5.0, SD = 0.7) highly intense strenuous exercise, with an estimated mean differences of 0.47 mm (95% CI: 0.35-0.59 mm; P < 0.0001) and in Achilles tendon thickness before (M = 4.4, SD = 0.4) and after (M = 4.5, SD = 0.5) workout, with an estimated difference of 0.17 mm (95% CI: 0.04-0.29 mm; P < 0.01). However, there was no significant difference in fascia plantaris thickness before (M = 3.4, SD = 0.5) and after (M = 3.4, SD = 0.5) workout (P = 0.97). A significant increase in the thickness of the patellar and Achilles tendons was found in response to strenuous, highly intense CrossFit exercises. In order to understand the underlying mechanisms of the findings and possibly utilize this to gain a better understanding, further studies must be conducted. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Tibiofemoral Compression Force Differences Using Laxity- and Force-Based Initial Graft Tensioning Techniques in the ACL-Reconstructed Knee

    PubMed Central

    Fleming, Braden C.; Brady, Mark F.; Bradley, Michael P.; Banerjee, Rahul; Hulstyn, Michael J.; Fadale, Paul D.

    2008-01-01

    Purpose To document the tibiofemoral (TF) compression forces produced during clinical initial graft tension protocols. Methods An image analysis system was used to track the position of the tibia relative to the femur in 11 cadaver knees. TF compression forces were quantified using thin-film pressure sensors. Prior to performing ACL reconstructions with patellar tendon grafts, measurements of TF compression force were obtained from the ACL-intact knee with knee flexion. ACL reconstructions were then performed using “force-based” and “laxity-based” graft tension approaches. Within each approach, high- and low-tension conditions were compared to the ACL-intact condition over the range of knee flexion angles. Results The TF compression forces for all initial graft tension conditions were significantly greater than that of the normal knee when the knee was in full extension (0°). The TF compression forces when using the laxity-based approach were greater than those produced with the force-based approach. However the laxity-based approach was necessary to restore normal laxity at the time of surgery. Conclusions The initial graft tension conditions produce different TF compressive force profiles at the time of surgery. A compromise must be made between restoring knee laxity or TF compressive forces when reconstructing the ACL with patellar tendon graft. Clinical Relevance The TF compression forces were greater in the ACL-reconstructed knee for all the initial graft tension conditions when compared to the ACL-intact knee, and that clinically relevant initial graft tension conditions produce different TF compressive forces. PMID:18760214

  7. Results of arthroscopic treatment in unresolved Osgood-Schlatter disease in athletes.

    PubMed

    Circi, Esra; Beyzadeoglu, Tahsin

    2017-02-01

    In this study we aimed to determine outcomes following arthroscopic ossicle excision in athletes with unresolved Osgood-Schlatter disease (OSD). Arthroscopy was performed on 11 patients (11 knees) with OSD between September 2008 and November 2014. Surgical treatment inclusion criteria were determined as: failure of conservative treatment; isolated pain over the tibial tubercle and distal patellar tendon; pain limiting sporting performance at a competitive level. All patients had a documented history of OSD; the mean duration of persistent pain over the tibial tubercle was 15.5 months. The mean age was 23 years. The mean follow-up period was 66.1 months. The mean latency in returning to sports related training activities after the surgery was 6.7 weeks. The mean Kujala patello-femoral score improved from 82.9 points pre-operatively, to 98.5 points at the final follow-up (p < 0.01). The mean Lysholm knee scale score was 87.5 points in the pre-operative period, increasing to a score of 96.9 points at final follow-up (p < 0.01). The mean Tegner activity level score was 7.5 in the pre-operative period, increasing to 8.5 post-operatively (p < 0.01). We investigated the functional outcomes after arthroscopic treatment of unresolved OSD in athletes. All athletes with OSD showed satisfactory functional recovery following arthroscopic treatment. All patients were able to return to the same level of athletic activity. Arthroscopic surgery for unresolved OSD has the major advantage of faster recovery and avoiding damage to the patellar tendon.

  8. Relationship between the skeletal maturation of the distal attachment of the patellar tendon and physical features in preadolescent male football players.

    PubMed

    Nakase, Junsuke; Aiba, Tomohiro; Goshima, Kenichi; Takahashi, Ryohei; Toratani, Tatsuhiro; Kosaka, Masahiro; Ohashi, Yoshinori; Tsuchiya, Hiroyuki

    2014-01-01

    The aim of this study was to compare ultrasonography stages of the tibial tuberosity development and physical features. This study examined 200 knees in 100 male football players aged 10-15 years. Tibial tuberosity development on ultrasonography was divided into 3 stages: Sonolucent stage (stage S), Individual stage (stage I), and Connective stage (stage C). Age, height, quadriceps and hamstring muscle tightness, and muscle strength in knee extension and flexion were determined. These findings were compared with the respective stages of development. The tibial tuberosity was stage S in 27 knees, stage I in 69 knees, and stage C in 104 knees, with right and left sides at the same stage in 95 %. Average age and height significantly increased with advancing tibial tuberosity development. Quadriceps tightness increased with tibial tuberosity development. Hamstring tightness decreased with development. The strength of both knee extension and flexion increased with advancing development, with a greater change seen in knee extension, hamstring/quadriceps ratio: stage C, 0.74; stage A, 0.64; stage E, 0.53. Osgood-Schlatter pathogenesis reportedly involves increased quadriceps tightness with rapidly increasing femoral length during tibial tuberosity development. In this study, it was confirmed that quadriceps tightness increased, yet hamstring tightness decreased, suggesting that quadriceps tightness is not due to femoral length alone. Other factors, including muscle strength, may be involved. The study shows that thigh muscle tightness and thigh muscle performance change with the skeletal maturation of the distal attachment of the patellar tendon. These results add new information to the pathogenesis of Osgood-Schlatter disease.

  9. Simultaneous bilateral Achilles tendon ruptures associated with statin medication despite regular rock climbing exercise.

    PubMed

    Carmont, Michael R; Highland, Adrian M; Blundell, Christopher M; Davies, Mark B

    2009-11-01

    Ruptures of the Achilles tendon are common however simultaneous ruptures occur less frequently. Eccentric loading exercise programmes have been used to successfully treat Achilles tendinopathy. We report a case of simultaneous bilateral Achilles tendon rupture in a patient predisposed to rupture due to longstanding raised serum lipoprotein and recently introduced therapeutic statin medication. The patient was also a keen rock climber and had regularly undertaken loading exercise. This case illustrates that the therapeutic effect of mixed loading exercises for the Achilles tendon may not be adequate to overcome the predisposition to rupture caused by hyperlipidaemia and statin medication.

  10. Influence of track surface on the equine superficial digital flexor tendon loading in two horses at high speed trot.

    PubMed

    Crevier-Denoix, N; Pourcelot, P; Ravary, B; Robin, D; Falala, S; Uzel, S; Grison, A C; Valette, J P; Denoix, J M; Chateau, H

    2009-03-01

    Although track surfaces are a risk factor of tendon injuries, their effects on tendon loading at high speed are unknown. Using a noninvasive ultrasonic technique, it is now possible to evaluate the forces in the superficial digital flexor tendon (SDFT) in exercise conditions. To compare the effects of an all-weather waxed track (W) vs. a crushed sand track (S), on the SDFT loading in the trotter horse at high speed. Two trotter horses were equipped with the ultrasonic device (1 MHz ultrasonic probe, fixed on the palmar metacarpal area of the right forelimb). For each trial, data acquisition was made at 400 Hz and 10 consecutive strides were analysed. In each session, the 2 track surfaces were tested in a straight line. The speed was imposed at 10 m/s and recorded. The right forelimb was also equipped with a dynamometric horseshoe and skin markers. The horse was filmed with a high-speed camera (600 Hz); all recordings were synchronised. Statistical differences were tested using the GLM procedure (SAS; P < 0.05). Maximal tendon force was significantly lower on W compared with S. In addition to maximal force peaks around mid-stance, earlier peaks were observed, more pronounced on S than on W, at about 13% (horse 2) and 30% (both horses) of the stance phase. Comparison with kinematic data revealed that these early peaks were accompanied by plateaux in the fetlock angle-time chart. For high tendon forces, the tendon maximal loading rate was significantly lower on W than on S. CONCLUSIONS AND POTENTIAL CLINICAL RELEVANCE: The all-weather waxed track appears to induce a lesser and more gradual SDFT loading than crushed sand. The SDFT loading pattern at high speed trot suggests proximal interphalangeal joint movements during limb loading.

  11. Effects of Increased Loading on In Vivo Tendon Properties: A Systematic Review

    PubMed Central

    WIESINGER, HANS-PETER; KÖSTERS, ALEXANDER; MÜLLER, ERICH; SEYNNES, OLIVIER R.

    2015-01-01

    ABSTRACT Introduction In vivo measurements have been used in the past two decades to investigate the effects of increased loading on tendon properties, yet the current understanding of tendon macroscopic changes to training is rather fragmented, limited to reports of tendon stiffening, supported by changes in material properties and/or tendon hypertrophy. The main aim of this review was to analyze the existing literature to gain further insights into tendon adaptations by extracting patterns of dose-response and time-course. Methods PubMed/Medline, SPORTDiscus, and Google Scholar databases were searched for studies examining the effect of training on material, mechanical, and morphological properties via longitudinal or cross-sectional designs. Results Thirty-five of 6440 peer-reviewed articles met the inclusion criteria. The key findings were i) the confirmation of a nearly systematic adaptation of tendon tissue to training, ii) the important variability in the observed changes in tendon properties between and within studies, and iii) the absence of a consistent incremental pattern regarding the dose-response or the time-course relation of tendon adaptation within the first months of training. However, long-term (years) training was associated with a larger tendon cross-sectional area, without any evidence of differences in material properties. Our analysis also highlighted several gaps in the existing literature, which may be addressed in future research. Conclusions In line with some cross-species observations about tendon design, tendon cross-sectional area allegedly constitutes the ultimate adjusting parameter to increased loading. We propose here a theoretical model placing tendon hypertrophy and adjustments in material properties as parts of the same adaptive continuum. PMID:25563908

  12. Dental pulp stem cells express tendon markers under mechanical loading and are a potential cell source for tissue engineering of tendon-like tissue.

    PubMed

    Chen, Yu-Ying; He, Sheng-Teng; Yan, Fu-Hua; Zhou, Peng-Fei; Luo, Kai; Zhang, Yan-Ding; Xiao, Yin; Lin, Min-Kui

    2016-12-16

    Postnatal mesenchymal stem cells have the capacity to differentiate into multiple cell lineages. This study explored the possibility of dental pulp stem cells (DPSCs) for potential application in tendon tissue engineering. The expression of tendon-related markers such as scleraxis, tenascin-C, tenomodulin, eye absent homologue 2, collagens I and VI was detected in dental pulp tissue. Interestingly, under mechanical stimulation, these tendon-related markers were significantly enhanced when DPSCs were seeded in aligned polyglycolic acid (PGA) fibre scaffolds. Furthermore, mature tendon-like tissue was formed after transplantation of DPSC-PGA constructs under mechanical loading conditions in a mouse model. This study demonstrates that DPSCs could be a potential stem cell source for tissue engineering of tendon-like tissue.

  13. Viscoelastic shear lag model to predict the micromechanical behavior of tendon under dynamic tensile loading.

    PubMed

    Wu, Jiayu; Yuan, Hong; Li, Longyuan; Fan, Kunjie; Qian, Shanguang; Li, Bing

    2018-01-21

    Owing to its viscoelastic nature, tendon exhibits stress rate-dependent breaking and stiffness function. A Kelvin-Voigt viscoelastic shear lag model is proposed to illustrate the micromechanical behavior of the tendon under dynamic tensile conditions. Theoretical closed-form expressions are derived to predict the deformation and stress transfer between fibrils and interfibrillar matrix while tendon is dynamically stretched. The results from the analytical solutions demonstrate that how the fibril overlap length and fibril volume fraction affect the stress transfer and mechanical properties of tendon. We find that the viscoelastic property of interfibrillar matrix mainly results in collagen fibril failure under fast loading rate or creep rupture of tendon. However, discontinuous fibril model and hierarchical structure of tendon ensure relative sliding under slow loading rate, helping dissipate energy and protecting fibril from damage, which may be a key reason why regularly staggering alignment microstructure is widely selected in nature. According to the growth, injury, healing and healed process of tendon observed by many researchers, the conclusions presented in this paper agrees well with the experimental findings. Additionally, the emphasis of this paper is on micromechanical behavior of tendon, whereas this analytical viscoelastic shear lag model can be equally applicable to other soft or hard tissues, owning the similar microstructure. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Imbalances in the Development of Muscle and Tendon as Risk Factor for Tendinopathies in Youth Athletes: A Review of Current Evidence and Concepts of Prevention

    PubMed Central

    Mersmann, Falk; Bohm, Sebastian; Arampatzis, Adamantios

    2017-01-01

    Tendons feature the crucial role to transmit the forces exerted by the muscles to the skeleton. Thus, an increase of the force generating capacity of a muscle needs to go in line with a corresponding modulation of the mechanical properties of the associated tendon to avoid potential harm to the integrity of the tendinous tissue. However, as summarized in the present narrative review, muscle and tendon differ with regard to both the time course of adaptation to mechanical loading as well as the responsiveness to certain types of mechanical stimulation. Plyometric loading, for example, seems to be a more potent stimulus for muscle compared to tendon adaptation. In growing athletes, the increased levels of circulating sex hormones might additionally augment an imbalanced development of muscle strength and tendon mechanical properties, which could potentially relate to the increasing incidence of tendon overload injuries that has been indicated for adolescence. In fact, increased tendon stress and strain due to a non-uniform musculotendinous development has been observed recently in adolescent volleyball athletes, a high-risk group for tendinopathy. These findings highlight the importance to deepen the current understanding of the interaction of loading and maturation and demonstrate the need for the development of preventive strategies. Therefore, this review concludes with an evidence-based concept for a specific loading program for increasing tendon stiffness, which could be implemented in the training regimen of young athletes at risk for tendinopathy. This program incorporates five sets of four contractions with an intensity of 85–90% of the isometric voluntary maximum and a movement/contraction duration that provides 3 s of high magnitude tendon strain. PMID:29249987

  15. Effect of Age and Proteoglycan Deficiency on Collagen Fiber Re-Alignment and Mechanical Properties in Mouse Supraspinatus Tendon

    PubMed Central

    Connizzo, Brianne K.; Sarver, Joseph J.; Iozzo, Renato V.; Birk, David E.; Soslowsky, Louis J.

    2013-01-01

    Collagen fiber realignment is one mechanism by which tendon responds to load. Re-alignment is altered when the structure of tendon is altered, such as in the natural process of aging or with alterations of matrix proteins, such as proteoglycan expression. While changes in re-alignment and mechanical properties have been investigated recently during development, they have not been studied in (1) aged tendons, or (2) in the absence of key proteoglycans. Collagen fiber re-alignment and the corresponding mechanical properties are quantified throughout tensile mechanical testing in both the insertion site and the midsubstance of mouse supraspinatus tendons in wild type (WT), decorin-null (Dcn-/-), and biglycan-null (Bgn-/-) mice at three different ages (90 days, 300 days, and 570 days). Percent relaxation was significantly decreased with age in the WT and Dcn-/- tendons, but not in the Bgn-/- tendons. Changes with age were found in the linear modulus at the insertion site where the 300 day group was greater than the 90 day and 570 day group in the Bgn-/- tendons and the 90 day group was smaller than the 300 day and 570 day groups in the Dcn-/- tendons. However, no changes in modulus were found across age in WT tendons were found. The midsubstance fibers of the WT and Bgn-/- tendons were initially less aligned with increasing age. The re-alignment was significantly altered with age in the WT tendons, with older groups responding to load later in the mechanical test. This was also seen in the Dcn-/- midsubstance and the Bgn-/- insertion, but not in the other locations. Although some studies have found changes in the WT mechanical properties with age, this study did not support those findings. However, it did show fiber re-alignment changes at both locations with age, suggesting a breakdown of tendon′s ability to respond to load in later ages. In the proteoglycan-null tendons however, there were changes in the mechanical properties, accompanied only by location-dependent re-alignment changes, suggesting a site-specific role for these molecules in loading. Finally, changes in the mechanical properties did not occur in concert with changes in re-alignment, suggesting that typical mechanical property measurements alone are insufficient to describe how structural alterations affect tendon′s response to load. PMID:23445064

  16. Chronic Quadriceps Tendon Rupture After Total Knee Arthroplasty Augmented With Synthetic Mesh.

    PubMed

    Ormaza, Amaia; Moreta, Jesús; Mosquera, Javier; de Ugarte, Oskar Sáez; Mozos, José Luis Martinez-de Los

    2017-01-01

    Tear of the quadriceps tendon after revision or primary total knee arthroplasty is a rare complication, but when it occurs, this injury has serious functional consequences. In complete tears, the outcome of direct repair is unpredictable, and several authors recommend that the suture should be reinforced. Several techniques have been described, including the use of autografts, allografts, and synthetic mesh. The goal of this study was to assess the outcomes of a reconstruction technique augmented with synthetic mesh. A retrospective study was performed involving 3 patients who had chronic partial quadriceps tendon tear after total knee revision. In 2 cases, proximal quadriceps release was performed. When conservative management failed, surgical reconstruction with suture reinforced with synthetic mesh was attempted. The knee was immobilized in full extension for 6 weeks after the surgical procedure. A minimum follow-up of 12 months was required to assess results. All reconstructions showed clinical success at a mean follow-up of 19 months. Mean Knee Society Score improved from 55.7 to 87.3, with average postoperative extensor lag of 3.3° (range, 0°-10°). The mean visual analog scale pain score was 2.3 (range, 0-4). No complications were reported. Synthetic mesh has previously been shown to be an effective treatment for patellar tendon repairs after total knee replacement, but there have been few articles on quadriceps rupture. Surgical reconstruction with synthetic mesh is a viable option that provides good functional outcomes in chronic quadriceps tendon rupture after total knee arthroplasty. [Orthopedics. 2017; 40(1):38-42.]. Copyright 2016, SLACK Incorporated.

  17. Mechanical Strength of the Side-to-Side Tendon Attachment for Mismatched Tendon Sizes and Shapes

    PubMed Central

    Fridén, Jan; Tirrell, Timothy F.; Bhola, Siddharth; Lieber, Richard L.

    2015-01-01

    Summary Certain combinations are advised against in tendon transfers due to size or shape mismatches between donor and recipient tendons. In this study, ultimate load, stiffness and Young’s modulus were measured in two tendon-to-tendon attachments with intentionally mismatched donor and recipient tendons - pronator teres (PT)-to-extensor carpi radialis brevis (ECRB) and flexor carpi ulnaris (FCU)-to-extensor digitorum communis (EDC). FCU-EDC attachments failed at higher loads than PT-to-ECRB attachments but they had similar modulus and stiffness values. Ultimate tensile strength of the tendon attachments exceeded the maximum predicted contraction force of any of the affected muscles, with safety factors of 4x and 2x for the FCU-to-EDC and PT-to-ECRB constructs, respectively. This implies that size and shape mismatch should not be a contraindication to tendon attachment in transfers. Further, these safety factors strongly suggest that no postoperative immobilization of these attachments is necessary. PMID:24413573

  18. Medial patellofemoral ligament reconstruction with a divergent patellar transverse 2-tunnel technique.

    PubMed

    Panni, Alfredo Schiavone; Alam, Mahbub; Cerciello, Simone; Vasso, Michele; Maffulli, Nicola

    2011-12-01

    The medial patellofemoral ligament (MPFL) is the primary passive restraint to lateral patellar dislocation and there is increasing awareness of its role in recurrent lateral patellar instability. This study was conducted to prospectively analyze the functional results of a modified MPFL reconstruction technique in recurrent patellar dislocation. Case series; Level of evidence, 4. Forty-eight patients (51 knees) with at least 3 episodes of lateral patellar dislocation who had been treated with a 6-month rehabilitation protocol were included in this study. All patients practiced sports regularly. Reconstruction was with a semitendinosus tendon using a divergent 2-tunnel technique. Outcome was evaluated with the Kujala, Larsen, modified Lysholm, and Fulkerson outcome scores. Patient satisfaction with range of motion, pain, and sporting activities was also assessed. Three patients were lost at the final follow-up, giving a follow-up rate of 94%. The mean follow-up was 33 months. There was no patella dislocation postoperatively. The mean Kujala score improved significantly (P < .01) from 56.7 ± 17.7 (2 × standard deviation) preoperatively to 86.8 ± 14.4 postoperatively. The mean Larsen score improved significantly (P < .01) from 12.4 ± 3.2 to 17.1 ± 2.7. The mean Fulkerson score improved significantly (P < .01) from 59.2 ± 21.8 to 90.1 ± 14. The mean modified Lysholm score improved significantly (P < .01) from 57.6 ± 19.6 to 88.1 ± 16.2. Sixty-four percent of patients returned to the same type of sport at the same level, 16% reduced the level or type of sport for reasons unrelated to the surgery, while 20% reduced the level of sport or changed it for reasons related to surgery. Eighty-seven percent were either satisfied or very satisfied with the pain relief achieved. The patellar tilt decreased significantly from a preoperative mean of 11.1° to 8.9° at the last follow-up (P = .02). The mean preoperative Insall-Salvati ratio of 1.1 decreased to 1.06, although the change was not significant (P = .1). The results of modified MPFL reconstructions are encouraging, with minimal risks of redislocation and an overall patient satisfaction rate of over 80%. These early and medium-term results are comparable with those of other MPFL reconstruction techniques reported in the literature.

  19. Effect of tendon vibration during wide-pulse neuromuscular electrical stimulation (NMES) on the decline and recovery of muscle force.

    PubMed

    Bochkezanian, Vanesa; Newton, Robert U; Trajano, Gabriel S; Vieira, Amilton; Pulverenti, Timothy S; Blazevich, Anthony J

    2017-05-02

    Neuromuscular electrical stimulation (NMES) is commonly used to activate skeletal muscles and reverse muscle atrophy in clinical populations. Clinical recommendations for NMES suggest the use of short pulse widths (100-200 μs) and low-to-moderate pulse frequencies (30-50 Hz). However, this type of NMES causes rapid muscle fatigue due to the (non-physiological) high stimulation intensities and non-orderly recruitment of motor units. The use of both wide pulse widths (1000 μs) and tendon vibration might optimize motor unit activation through spinal reflex pathways and thus delay the onset of muscle fatigue, increasing muscle force and mass. Thus, the objective of this study was to examine the acute effects of patellar tendon vibration superimposed onto wide-pulse width (1000 μs) knee extensor electrical stimulation (NMES, 30 Hz) on peak muscle force, total impulse before "muscle fatigue", and the post-exercise recovery of muscle function. Tendon vibration (Vib), NMES (STIM) or NMES superimposed onto vibration (STIM + Vib) were applied in separate sessions to 16 healthy adults. Total torque-time integral (TTI), maximal voluntary contraction torque (MVIC) and indirect measures of muscle damage were tested before, immediately after, 1 h and 48 h after each stimulus. TTI increased (145.0 ± 127.7%) in STIM only for "positive responders" to the tendon vibration (8/16 subjects), but decreased in "negative responders" (-43.5 ± 25.7%). MVIC (-8.7%) and rectus femoris electromyography (RF EMG) (-16.7%) decreased after STIM (group effect) for at least 1 h, but not after STIM + Vib. No changes were detected in indirect markers of muscle damage in any condition. Tendon vibration superimposed onto wide-pulse width NMES increased TTI only in 8 of 16 subjects, but reduced voluntary force loss (fatigue) ubiquitously. Negative responders to tendon vibration may derive greater benefit from wide-pulse width NMES alone.

  20. Achilles Tendon Loading During Heel-Raising and -Lowering Exercises

    PubMed Central

    Revak, Andrew; Diers, Keith; Kernozek, Thomas W.; Gheidi, Naghmeh; Olbrantz, Christina

    2017-01-01

    Context: Achilles tendinopathies are common injuries during sport participation, although men are more prone to Achilles tendon injuries than women. Heel-raising and -lowering exercises are typically suggested for Achilles tendon rehabilitation. Objective: To compare the estimated Achilles tendon loading variables and the ankle range of motion (ROM) using a musculoskeletal model during commonly performed heel-raising and -lowering exercises. Design: Controlled laboratory study. Setting: University biomechanics laboratory. Patients or Other Participants: Twenty-one healthy men (age = 21.59 ± 1.92 years, height = 178.22 ± 8.02 cm, mass = 75.81 ± 11.24 kg). Intervention(s): Each participant completed 4 exercises: seated heel raising and lowering, bilateral standing heel raising and lowering, bilateral heel raising and unilateral lowering, and unilateral heel raising and lowering. Main Outcome Measure(s): A repeated-measures multivariate analysis of variance (α = .05) was used to compare Achilles tendon stress, force, and strain and ankle ROM for each exercise. Kinematic data were recorded at 180 Hz with 15 motion-analysis cameras synchronized with kinetic data collected from a force platform sampled at 1800 Hz. These data were then entered in a musculoskeletal model to estimate force in the triceps surae. For each participant, we determined Achilles tendon stress by measuring cross-sectional images using ultrasound. Results: Peak Achilles tendon loading was lowest when performing the seated heel-raising and -lowering exercise and highest when performing the unilateral heel-raising and -lowering exercise. Loading was greater for the unilateral exercise or portions of the exercise that were performed unilaterally. Conclusions: Bilateral and seated exercises with less weight-bearing force resulted in less Achilles tendon loading. These exercises may serve as progressions during the rehabilitation process before full-body weight-bearing, unilateral exercises are allowed. Ankle ROM did not follow the same order as loading and may need additional monitoring or instruction during rehabilitation. PMID:28145739

  1. Measuring the effect of femoral malrotation on knee joint biomechanics for total knee arthroplasty using computational simulation

    PubMed Central

    Kang, K-T.; Koh, Y-G.; Son, J.; Kwon, O-R.; Baek, C.; Jung, S. H.

    2016-01-01

    Objectives Malrotation of the femoral component can result in post-operative complications in total knee arthroplasty (TKA), including patellar maltracking. Therefore, we used computational simulation to investigate the influence of femoral malrotation on contact stresses on the polyethylene (PE) insert and on the patellar button as well as on the forces on the collateral ligaments. Materials and Methods Validated finite element (FE) models, for internal and external malrotations from 0° to 10° with regard to the neutral position, were developed to evaluate the effect of malrotation on the femoral component in TKA. Femoral malrotation in TKA on the knee joint was simulated in walking stance-phase gait and squat loading conditions. Results Contact stress on the medial side of the PE insert increased with internal femoral malrotation and decreased with external femoral malrotation in both stance-phase gait and squat loading conditions. There was an opposite trend in the lateral side of the PE insert case. Contact stress on the patellar button increased with internal femoral malrotation and decreased with external femoral malrotation in both stance-phase gait and squat loading conditions. In particular, contact stress on the patellar button increased by 98% with internal malrotation of 10° in the squat loading condition. The force on the medial collateral ligament (MCL) and the lateral collateral ligament (LCL) increased with internal and external femoral malrotations, respectively. Conclusions These findings provide support for orthopaedic surgeons to determine a more accurate femoral component alignment in order to reduce post-operative PE problems. Cite this article: K-T. Kang, Y-G. Koh, J. Son, O-R. Kwon, C. Baek, S. H. Jung, K. K. Park. Measuring the effect of femoral malrotation on knee joint biomechanics for total knee arthroplasty using computational simulation. Bone Joint Res 2016;5:552–559. DOI: 10.1302/2046-3758.511.BJR-2016-0107.R1. PMID:28094763

  2. A mathematical model to describe the nonlinear elastic properties of the gastrocnemius tendon of chickens.

    PubMed

    Foutz, T L

    1991-03-01

    A phenomenological model was developed to describe the nonlinear elastic behavior of the avian gastrocnemius tendon. Quasistatic uniaxial tensile tests were used to apply a deformation and resulting load on the tendon at a deformation rate of 5 mm/min. Plots of deformation versus load indicated a nonlinear loading response. By calculating engineering stress and engineering strain, the experimental data were normalized for tendon shape. The elastic response was determined from stress-strain curves and was found to vary with engineering strain. The response to the applied engineering strain could best be described by a mathematical model that combined a linear function and a nonlinear function. Three parameters in the model were developed to represent the nonlinear elastic behavior of the tendon, thereby allowing analysis of elasticity without prior knowledge of engineering strain. This procedure reduced the amount of data needed for the statistical analysis of nonlinear elasticity.

  3. Simultaneous anatomic reconstruction of the acromioclavicular and coracoclavicular ligaments using a single tendon graft.

    PubMed

    Shin, Sang-Jin; Campbell, Sean; Scott, Jonathan; McGarry, Michelle H; Lee, Thay Q

    2014-09-01

    The purpose of this study was to introduce a novel surgical technique for simultaneous anatomic reconstruction of the acromioclavicular and coracoclavicular ligaments using a single tendon graft and to compare its biomechanical characteristics to those of a coracoid cerclage reconstruction of the coracoclavicular ligaments. Six matched pairs of human acromioclavicular joints with an average age of 54.8 ± 7.8 years were used. One shoulder from each pair received the single tendon acromioclavicular-coracoclavicular reconstruction; the contralateral shoulder received the coracoid cerclage reconstruction. Bovine extensor tendon was used for both techniques. The single tendon acromioclavicular-coracoclavicular reconstruction technique provided anatomic restoration of the two coracoclavicular ligaments and the superior and inferior acromioclavicular ligaments simultaneously using one coracoid hole, one acromion hole, and two clavicular holes with interference screws. Anterior-posterior and superior-inferior translations were quantified for all specimens before and after reconstruction, followed by load to failure testing. Following coracoid cerclage reconstruction, total anterior-posterior translation was significantly greater than intact (10.0 ± 5.7 mm; p = 0.008). Following single tendon acromioclavicular-coracoclavicular reconstruction, there was no significant difference in anterior-posterior translation compared to intact (-1.6 ± 2.2 mm; n.s.). The coracoid cerclage technique demonstrated significantly greater anterior-posterior translation than the single tendon acromioclavicular-coracoclavicular technique (p = 0.007). Both techniques restored superior-inferior translation to the intact condition (n.s.). Ultimate load, deformation at ultimate load, and energy absorbed at ultimate load were significantly greater after acromioclavicular-coracoclavicular reconstruction than after coracoid cerclage reconstruction (p < 0.05). This novel single tendon anatomic acromioclavicular-coracoclavicular reconstruction provided greater stability and stronger load to failure characteristics than the isolated coracoid cerclage reconstruction. A simultaneous acromioclavicular-coracoclavicular reconstruction technique using a single free tendon graft provided anatomic reconstruction of the conoid, trapezoid, and superior and inferior acromioclavicular ligaments and may reduce postoperative subluxation.

  4. Achilles tendon structure improves on UTC imaging over a 5-month pre-season in elite Australian football players.

    PubMed

    Docking, S I; Rosengarten, S D; Cook, J

    2016-05-01

    Pre-season injuries are common and may be due to a reintroduction of training loads. Tendons are sensitive to changes in load, making them vulnerable to injury in the pre-season. This study investigated changes in Achilles tendon structure on ultrasound tissue characterization (UTC) over the course of a 5-month pre-season in elite male Australian football players. Eighteen elite male Australian football players with no history of Achilles tendinopathy and normal Achilles tendons were recruited. The left Achilles tendon was scanned with UTC to quantify the stability of the echopattern. Participants were scanned at the start and completion of a 5-month pre-season. Fifteen players remained asymptomatic over the course of the pre-season. All four echo-types were significantly different at the end of the pre-season, with the overall echopattern suggesting an improvement in Achilles tendon structure. Three of the 18 participants developed Achilles tendon pain that coincided with a change in the UTC echopattern. This study demonstrates that the UTC echopattern of the Achilles tendon improves over a 5-month pre-season training period, representing increased fibrillar alignment. However, further investigation is needed to elucidate with this alteration in the UTC echopattern results in improved tendon resilience and load capacity. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Alterations in tendon microenvironment in response to mechanical load: potential molecular targets for treatment strategies

    PubMed Central

    Fouda, Mohamed B; Thankam, Finosh G; Dilisio, Matthew F; Agrawal, Devendra K

    2017-01-01

    Rotator cuff (RC) tendons could beinflicted in many ways with an eventual outcome of pain, weakness and disability, which represent a large burden on health care cost. However, optimal healing, either conservatively or with surgical intervention, remains an issue that needs further investigation. Disorders of the RC tendons may result from external factors like trauma, or internal factors through physiologic and metabolic derangement. Most RC tendon disorders may be asymptomatic and may result from an over-activity of the inflicted shoulder and its tendons. Such tendon disorders are poorly diagnosed since patients do not seek medical attention until pain or weakness ensue. Immunological and biochemical events in RC disorders due to mechanical intolerance have not been investigated. Generally, the mechanical load drives normal physiological properties of the tendon. But, mechanical overload/burden exerts stress on tenocytes, and disrupts the tendon microenvironment by triggering a multitude of signaling pathways leading to extracellular matrix remodeling, disorganization, alteration in collagen composition and apoptosis. These events result in weak tendon which is highly susceptible to rupture or tear. In this article, we critically reviewed the intrinsic signaling pathways that are excessively triggered by continuous mechanical load and the counteracting physiological responses and associated derangements. The elucidation of the molecular events underlying mechanical stress-induced symptomatic/asymptomatic tendinopathy could provide information on potential target sites for translational application in the management of rotator cuff disorders. PMID:29118899

  6. The interfascicular matrix enables fascicle sliding and recovery in tendon, and behaves more elastically in energy storing tendons

    PubMed Central

    Thorpe, Chavaunne T.; Godinho, Marta S.C.; Riley, Graham P.; Birch, Helen L.; Clegg, Peter D.; Screen, Hazel R.C.

    2015-01-01

    While the predominant function of all tendons is to transfer force from muscle to bone and position the limbs, some tendons additionally function as energy stores, reducing the cost of locomotion. Energy storing tendons experience extremely high strains and need to be able to recoil efficiently for maximum energy storage and return. In the equine forelimb, the energy storing superficial digital flexor tendon (SDFT) has much higher failure strains than the positional common digital extensor tendon (CDET). However, we have previously shown that this is not due to differences in the properties of the SDFT and CDET fascicles (the largest tendon subunits). Instead, there is a greater capacity for interfascicular sliding in the SDFT which facilitates the greater extensions in this particular tendon (Thorpe et al., 2012). In the current study, we exposed fascicles and interfascicular matrix (IFM) from the SDFT and CDET to cyclic loading followed by a test to failure. The results show that IFM mechanical behaviour is not a result of irreversible deformation, but the IFM is able to withstand cyclic loading, and is more elastic in the SDFT than in the CDET. We also assessed the effect of ageing on IFM properties, demonstrating that the IFM is less able to resist repetitive loading as it ages, becoming stiffer with increasing age in the SDFT. These results provide further indications that the IFM is important for efficient function in energy storing tendons, and age-related alterations to the IFM may compromise function and predispose older tendons to injury. PMID:25958330

  7. Lower Extremity Kinematics During a Drop Jump in Individuals With Patellar Tendinopathy

    PubMed Central

    Rosen, Adam B.; Ko, Jupil; Simpson, Kathy J.; Kim, Seock-Ho; Brown, Cathleen N.

    2015-01-01

    Background: Patellar tendinopathy (PT) is a common degenerative condition in physically active populations. Knowledge regarding the biomechanics of landing in populations with symptomatic PT is limited, but altered mechanics may play a role in the development or perpetuation of PT. Purpose: To identify whether study participants with PT exhibited different landing kinematics compared with healthy controls. Study Design: Controlled laboratory study. Methods: Sixty recreationally active participants took part in this study; 30 had current signs and symptoms of PT, including self-reported pain within the patellar tendon during loading activities for at least 3 months and ≤80 on the Victorian Institute of Sport Assessment Scale–Patella (VISA-P). Thirty healthy participants with no history of PT or other knee joint pathology were matched by sex, age, height, and weight. Participants completed 5 trials of a 40-cm, 2-legged drop jump followed immediately by a 50% maximum vertical jump. Dependent variables of interest included hip, knee, and ankle joint angles at initial ground contact, peak angles, and maximum angular displacements during the landing phase in 3 planes. Independent-samples t tests (P ≤ .05) were utilized to compare the joint angles and angular displacements between PT and control participants. Results: Individuals with PT displayed significantly decreased peak hip (PT, 59.2° ± 14.6°; control, 67.2° ± 13.9°; P = .03) and knee flexion angles (PT, 74.8° ± 13.2°; control, 82.5° ± 9.0°; P = .01) compared with control subjects. The PT group displayed decreased maximum angular displacement in the sagittal plane at the hip (PT, 49.3° ± 10.8°; control, 55.2° ± 11.4°; P = .04) and knee (PT, 71.6° ± 8.4°; control, 79.7° ± 8.3°; P < .001) compared with the control group. Conclusion: Participants with PT displayed decreased maximum flexion and angular displacement in the sagittal plane, at both the knee and the hip. The altered movement patterns in those with PT may be perpetuating symptoms associated with PT and could be due to the contributions of the rectus femoris during dynamic movement. Clinical Relevance: Based on kinematic alterations in symptomatic participants, rehabilitation efforts may benefit from focusing on both the knee and the hip to treat symptoms associated with PT. PMID:26665034

  8. Is tibialis anterior tendon transfer effective for recurrent clubfoot?

    PubMed

    Gray, Kelly; Burns, Joshua; Little, David; Bellemore, Michael; Gibbons, Paul

    2014-02-01

    Tibialis anterior tendon transfer surgery forms a part of Ponseti management for children with congenital talipes equinovarus who, after initial correction, present with residual dynamic supination. Although retrospective studies support good outcomes, prospective longitudinal studies in this population are lacking. We assessed strength, plantar loading, ROM, foot alignment, function, satisfaction, and quality of life in patients with clubfoot that recurred after Ponseti casting who met indications for tibialis anterior tendon transfer surgery, and compared them with a group of patients with clubfoot treated with casting but whose deformity did not recur (therefore who were not indicated for tibialis anterior tendon transfer surgery). Twenty children with idiopathic congenital talipes equinovarus indicated for tibialis anterior tendon transfer surgery were recruited. Assessment at baseline (before surgery), and 3, 6, and 12 months (after surgery) included strength (hand-held dynamometry), plantar loading (capacitance transducer matrix platform), ROM (Dimeglio scale), foot alignment (Foot Posture Index(©)), function and satisfaction (disease-specific instrument for clubfoot), and quality of life (Infant Toddler Quality of Life Questionnaire™). Outcomes were compared with those of 12 age-matched children with congenital talipes equinovarus not indicated for tibialis anterior tendon transfer surgery. Followup was 100% in the control group and 95% (19 of 20) in the tibialis anterior transfer group. At baseline, the tibialis anterior tendon transfer group had a significantly worse eversion-to-inversion strength ratio, plantar loading, ROM, foot alignment, and function and satisfaction. At 3 months after surgery, eversion-to-inversion strength, plantar loading, and function and satisfaction were no longer different between groups. Improvements were maintained at 12 months after surgery (eversion-to-inversion strength mean difference, 8% body weight; 95% CI, -26% to 11%; p = 0.412; plantar loading, p > 0.251; function and satisfaction, p = 0.076). ROM remained less and foot alignment more supinated in the tibialis anterior tendon transfer group between baseline and followup (p < 0.001, p < 0.001). Tibialis anterior tendon transfer surgery was an effective procedure, which at 12-month followup restored the balance of eversion-to-inversion strength and resulted in plantar loading and function and satisfaction outcomes similar to those of age-matched children with congenital talipes equinovarus who after Ponseti casting were not indicated for tibialis anterior tendon transfer.

  9. Existence of life-time stable proteins in mature rats—Dating of proteins’ age by repeated short-term exposure to labeled amino acids throughout age

    PubMed Central

    Schjerling, Peter; Bornø, Andreas; Holm, Lars

    2017-01-01

    In vivo turnover rates of proteins covering the processes of protein synthesis and breakdown rates have been measured in many tissues and protein pools using various techniques. Connective tissue and collagen protein turnover is of specific interest since existing results are rather diverging. The aim of this study is to investigate whether we can verify the presence of protein pools within the same tissue with very distinct turnover rates over the life-span of rats with special focus on connective tissue. Male and female Lewis rats (n = 35) were injected with five different isotopically labeled amino acids tracers. The tracers were injected during fetal development (Day -10 to -2), after birth (Day 5–9), at weaning (Day 25–32) at puberty (Day 54–58) and at adulthood (Day 447–445). Subgroups of rats were euthanized three days after every injection period, at different time point between injection periods and lastly at day 472. Tissue (liver, muscle, eye lens and patellar tendon) and blood samples were collected after euthanization. The enrichment of the labeled amino acids in the tissue or blood samples was measured using GC-MS-MS. In muscle and liver we demonstrated a rapid decrease of tracer enrichments throughout the rat’s life, indicating that myofibrillar and cytoskeleton proteins have a high turnover. In contrast, the connective tissue protein in the eye lens and patellar tendon of the mature rat showed detainment of tracer enrichment injected during fetal development and first living days, indicating very slow turnover. The data support the hypothesis that some proteins synthesized during the early development and growth still exist much later in life of animals and hence has a very slow turnover rate. PMID:28957442

  10. Secure fixation of femoral bone plug with a suspensory button in anatomical anterior cruciate ligament reconstruction with bone-patellar tendon-bone graft

    PubMed Central

    TAKETOMI, SHUJI; INUI, HIROSHI; NAKAMURA, KENSUKE; YAMAGAMI, RYOTA; TAHARA, KEITARO; SANADA, TAKAKI; MASUDA, HIRONARI; TANAKA, SAKAE; NAKAGAWA, TAKUMI

    2015-01-01

    Purpose the efficacy and safety of using a suspensory button for femoral fixation in anatomical anterior cruciate ligament (ACL) reconstruction with bone-patellar tendon-bone (BPTB) graft have not been established. The purpose of the current study was to evaluate bone plug integration onto the femoral socket and migration of the bone plug and the EndoButton (EB) (Smith & Nephew, Andover, MA, USA) after rectangular tunnel ACL reconstruction with BPTB autograft. Methods thirty-four patients who underwent anatomical rectangular ACL reconstruction with BPTB graft using EB for femoral fixation and in whom three-dimensional (3D) computed tomography (CT) was performed one week and one year after surgery were included in this study. Bone plug integration onto the femoral socket, bone plug migration, soft tissue interposition, EB migration and EB rotation were evaluated on 3D CT. The clinical outcome was also assessed and correlated with the imaging outcomes. Results the bone plug was integrated onto the femoral socket in all cases. The incidence of bone plug migration, soft tissue interposition, EB migration and EB rotation was 15, 15, 9 and 56%, respectively. No significant association was observed between the imaging outcomes. The postoperative mean Lysholm score was 97.1 ± 5.0 points. The postoperative side-to-side difference, evaluated using a KT-2000 arthrometer, averaged 0.5 ± 1.3 mm. There were no complications associated with EB use. Imaging outcomes did not affect the postoperative KT side-to-side difference. Conclusions the EB is considered a reliable device for femoral fixation in anatomical rectangular tunnel ACL reconstruction with BPTB autograft. Level of evidence Level IV, therapeutic case series. PMID:26889465

  11. Reduced Bearing Excursion After Mobile-Bearing Unicompartmental Knee Arthroplasty is Associated With Poor Functional Outcomes.

    PubMed

    Wahal, Naman; Gaba, Sahil; Malhotra, Rajesh; Kumar, Vijay; Pegg, Elise C; Pandit, Hemant

    2018-02-01

    A small proportion of patients with mobile unicompartmental knee arthroplasty (UKA) report poor functional outcomes in spite of optimal component alignment on postoperative radiographs. The purpose of this study is to assess whether there is a correlation between functional outcome and knee kinematics. From a cohort of consecutive cases of 150 Oxford medial UKA, patients with fair/poor functional outcome at 1-year postsurgery (Oxford Knee Score [OKS] < 34, n = 15) were identified and matched for age, gender, preoperative clinical scores, and follow-up period with a cohort of patients with good/excellent outcome (OKS ≥ 34, n = 15). In vivo kinematic assessment was performed using step-up and deep knee bend exercises under fluoroscopic imaging. The fluoroscopic videos were analyzed using MATLAB software to measure the variation in time taken to complete the exercises, patellar tendon angle, and bearing position with knee flexion angle. Mean OKS in the fair/poor group was 29.9 and the mean OKS in the good/excellent group was 41.1. The tibial slope, time taken to complete the exercises, and patellar tendon angle trend over the flexion range were similar in both the groups; however, bearing position and the extent of bearing excursion differed significantly. The total bearing excursion in the OKS < 34 group was significantly smaller than the OKS ≥ 34 group (35%). Furthermore, on average, the bearing was positioned 1.7 mm more posterior on the tibia in the OKS < 34 group. This study provides evidence that abnormal knee kinematics, in particular bearing excursion and positioning, are associated with worse functional outcomes after mobile UKA. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. An overview of structure, mechanical properties, and treatment for age-related tendinopathy.

    PubMed

    Zhou, B; Zhou, Y; Tang, K

    2014-04-01

    Tendons transfer tensile loads from muscle to bone, which enable joint motions and stabilize joints. Tendons sustain large mechanical loads in vivo and as a result, tendons were frequently injured. Aging has been confirmed as a predisposing factor of tendinopathy and bad recovery quality following tendon repair. Current treatment methods are generally not effective and involve either symptomatic relief with non-steroidal antiinflammatory drugs and physical therapy or surgery when conservative treatments failed. The limitation in treatment options is due to our incomplete knowledge of age-related tendinopathy. Studies over the past decades have uncovered a number of important mechanical and cellular changes of aging tendon. However, the basis of aging as a major risk factor for tendon injury and impaired tendon healing remained poorly understood. The objectives of this review are to provide an overview of the current knowledge about the aging-associated changes of structure, mechanical properties and treatment in tendon and highlight causes and therapies for age-related tendinopathy.

  13. Muscle contributions to medial tibiofemoral compartment contact loading following ACL reconstruction using semitendinosus and gracilis tendon grafts.

    PubMed

    Konrath, Jason M; Saxby, David J; Killen, Bryce A; Pizzolato, Claudio; Vertullo, Christopher J; Barrett, Rod S; Lloyd, David G

    2017-01-01

    The muscle-tendon properties of the semitendinosus (ST) and gracilis (GR) are substantially altered following tendon harvest for the purpose of anterior cruciate ligament reconstruction (ACLR). This study adopted a musculoskeletal modelling approach to determine how the changes to the ST and GR muscle-tendon properties alter their contribution to medial compartment contact loading within the tibiofemoral joint in post ACLR patients, and the extent to which other muscles compensate under the same external loading conditions during walking, running and sidestep cutting. Motion capture and electromyography (EMG) data from 16 lower extremity muscles were acquired during walking, running and cutting in 25 participants that had undergone an ACLR using a quadruple (ST+GR) hamstring auto-graft. An EMG-driven musculoskeletal model was used to estimate the medial compartment contact loads during the stance phase of each gait task. An adjusted model was then created by altering muscle-tendon properties for the ST and GR to reflect their reported changes following ACLR. Parameters for the other muscles in the model were calibrated to match the experimental joint moments. The medial compartment contact loads for the standard and adjusted models were similar. The combined contributions of ST and GR to medial compartment contact load in the adjusted model were reduced by 26%, 17% and 17% during walking, running and cutting, respectively. These deficits were balanced by increases in the contribution made by the semimembranosus muscle of 33% and 22% during running and cutting, respectively. Alterations to the ST and GR muscle-tendon properties in ACLR patients resulted in reduced contribution to medial compartment contact loads during gait tasks, for which the semimembranosus muscle can compensate.

  14. Multiscale mechanical integrity of human supraspinatus tendon in shear after elastin depletion.

    PubMed

    Fang, Fei; Lake, Spencer P

    2016-10-01

    Human supraspinatus tendon (SST) exhibits region-specific nonlinear mechanical properties under tension, which have been attributed to its complex multiaxial physiological loading environment. However, the mechanical response and underlying multiscale mechanism regulating SST behavior under other loading scenarios are poorly understood. Furthermore, little is known about the contribution of elastin to tendon mechanics. We hypothesized that (1) SST exhibits region-specific shear mechanical properties, (2) fiber sliding is the predominant mode of local matrix deformation in SST in shear, and (3) elastin helps maintain SST mechanical integrity by facilitating force transfer among collagen fibers. Through the use of biomechanical testing and multiphoton microscopy, we measured the multiscale mechanical behavior of human SST in shear before and after elastase treatment. Three distinct SST regions showed similar stresses and microscale deformation. Collagen fiber reorganization and sliding were physical mechanisms observed as the SST response to shear loading. Measures of microscale deformation were highly variable, likely due to a high degree of extracellular matrix heterogeneity. After elastase treatment, tendon exhibited significantly decreased stresses under shear loading, particularly at low strains. These results show that elastin contributes to tendon mechanics in shear, further complementing our understanding of multiscale tendon structure-function relationships. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Quadriceps Tendon Autograft in Anterior Cruciate Ligament Reconstruction: A Systematic Review.

    PubMed

    Hurley, Eoghan T; Calvo-Gurry, Manuel; Withers, Dan; Farrington, Shane K; Moran, Ray; Moran, Cathal J

    2018-05-01

    To systematically review the current evidence to ascertain whether quadriceps tendon autograft (QT) is a viable option in anterior cruciate ligament reconstruction. A literature review was conducted in accordance with Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines. Cohort studies comparing QT with bone-patellar tendon-bone autograft (BPTB) or hamstring tendon autograft (HT) were included. Clinical outcomes were compared, with all statistical analyses performed using IBM SPSS Statistics for Windows, version 22.0, with P < .05 being considered statistically significant. We identified 15 clinical trials with 1,910 patients. In all included studies, QT resulted in lower rates of anterior knee pain than BPTB. There was no difference in the rate of graft rupture between QT and BPTB or HT in any of the studies reporting this. One study found that QT resulted in greater knee stability than BPTB, and another study found increased stability compared with HT. One study found that QT resulted in improved functional outcomes compared with BPTB, and another found improved outcomes compared with HT, but one study found worse outcomes compared with BPTB. Current literature suggests QT is a viable option in anterior cruciate ligament reconstruction, with published literature showing comparable knee stability, functional outcomes, donor-site morbidity, and rerupture rates compared with BPTB and HT. Level III, systematic review of Level I, II, and III studies. Copyright © 2018 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  16. Effect of low dose and moderate dose gamma irradiation on the mechanical properties of bone and soft tissue allografts.

    PubMed

    Balsly, Colleen R; Cotter, Andrew T; Williams, Lisa A; Gaskins, Barton D; Moore, Mark A; Wolfinbarger, Lloyd

    2008-12-01

    The increased use of allograft tissue for musculoskeletal repair has brought more focus to the safety of allogenic tissue and the efficacy of various sterilization techniques. Gamma irradiation is an effective method for providing terminal sterilization to biological tissue, but it is also reported to have deleterious effects on tissue mechanics in a dose-dependent manner. At irradiation ranges up to 25 kGy, a clear relationship between mechanical strength and dose has yet to be established. The aim of this study was to investigate the mechanical properties of bone and soft tissue allografts, irradiated on dry ice at a low absorbed dose (18.3-21.8 kGy) and a moderate absorbed dose (24.0-28.5 kGy), using conventional compressive and tensile testing, respectively. Bone grafts consisted of Cloward dowels and iliac crest wedges, while soft tissue grafts consisted of patellar tendons, anterior tibialis tendons, semitendinosus tendons, and fascia lata. There were no statistical differences in mechanical strength or modulus of elasticity for any graft irradiated at a low absorbed dose, compared to control groups. Also, bone allografts and two soft tissue allografts (anterior tibialis and semitendinosus tendon) that were irradiated at a moderate dose demonstrated similar strength and modulus of elasticity values to control groups. The results of this study support the use of low dose and moderate dose gamma irradiation of bone grafts. For soft tissue grafts, the results support the use of low dose irradiation.

  17. Bone anchors or interference screws? A biomechanical evaluation for autograft ankle stabilization.

    PubMed

    Jeys, Lee; Korrosis, Sotiris; Stewart, Todd; Harris, Nicholas J

    2004-01-01

    Autograft stabilization uses free semitendinosus tendon grafts to anatomically reconstruct the anterior talofibular ligament. Study aims were to evaluate the biomechanical properties of Mitek GII anchors compared with the Arthrex Bio-Tenodesis Screw for free tendon reconstruction of the anterior talofibular ligament. There are no differences in load to failure and percentage specimen elongation at failure between the 2 methods. Controlled laboratory study using porcine models. Sixty porcine tendon constructs were failure tested. Re-creating the pull of the anterior talofibular ligament, loads were applied at 70 degrees to the bones. Thirty-six tendons were fixed to porcine tali and tested using a single pull to failure; 10 were secured with anchors and No. 2 Ethibond, 10 with anchors and FiberWire, 10 with screws and Fiberwire, and 6 with partially gripped screws. Cyclic preloading was conducted on 6 tendons fixed by anchors and on 6 tendons fixed by screws before failure testing. Two groups of 6 components fixed to the fibula were also tested. The talus single-pull anchor group produced a mean load of 114 N and elongation of 37% at failure. The talus single-pull screw group produced a mean load of 227 N and elongation of 22% at failure (P <.05). Cyclic preloading at 65% failure load before failure testing produced increases in load and decreases in elongation at failure. Partially gripped screws produced a load of 133 N and elongation of 30% at failure. The fibula model produced significant increases in load to failure for both. The human anterior talofibular ligament has loads of 139 N at failure with instability occurring at 20% elongation. Interference screw fixation produced significantly greater failure strength and less elongation at failure than bone anchors. The improved biomechanics of interference screws suggests that these may be more suited to in vivo reconstruction of the anterior talofibular ligament than are bone anchors.

  18. Aging Does Not Alter Tendon Mechanical Properties During Homeostasis, but does Impair Flexor Tendon Healing

    PubMed Central

    Ackerman, Jessica E.; Bah, Ibrahima; Jonason, Jennifer H.; Buckley, Mark R.; Loiselle, Alayna E.

    2017-01-01

    Aging is an important factor in disrupted homeostasis of many tissues. While an increased incidence of tendinopathy and tendon rupture are observed with aging, it is unclear whether this is due to progressive changes in tendon cell function and mechanics over time, or an impaired repair reaction from aged tendons in response to insult or injury. In the present study we examined changes in the mechanical properties of Flexor Digitorum Longus (FDL), Flexor Carpi Ulnaris (FCU), and tail fascicles in both male and female C57Bl/6 mice between 3-27 months of age to better understand the effects of sex and age on tendon homeostasis. No change in max load at failure was observed in any group over the course of aging, although there were significant decreases in toe and linear stiffness in female mice from 3-months to 15, and to 22-27-months. No changes in cell proliferation were observed with aging, although an observable decrease in cellularity occurred in 31-month old tendons. Given that aging did not dramatically alter tendon mechanical homeostasis we hypothesized that a disruption in tendon homeostasis, via acute injury would result in an impaired healing response. Significant decreases in max load, stiffness, and yield load were observed in repairs of 22-month old mice, relative to 4-month old mice. No changes in cell proliferation were observed between young and aged, however a dramatic loss of bridging collagen extracellular matrix was observed in aged repairs suggest that matrix production, but not cell proliferation leads to impaired tendon healing with aging. PMID:28419543

  19. Early changes in Achilles tendon behaviour in vivo following downhill backwards walking.

    PubMed

    Joseph, C W; Bradshaw, E J; Furness, T P; Kemp, J; Clark, R A

    2016-01-01

    Downhill backwards walking causes repeated, cyclical loading of the muscle-tendon unit. The effect this type of repeated loading has on the mechanical behaviour of the Achilles tendon is presently unknown. This study aimed to investigate the biomechanical response of the Achilles tendon aponeurosis complex following a downhill backwards walking protocol. Twenty active males (age: 22.3 ± 3.0 years; mass: 74.7 ± 5.6 kg; height: 1.8 ± 0.7 m) performed 60 min of downhill (8.5°), backwards walking on a treadmill at -0.67 m · s(-1). Data were collected before, immediately post, and 24-, 48- and 168-h post-downhill backwards walking. Achilles tendon aponeurosis elongation, strain and stiffness were measured using ultrasonography. Muscle force decreased immediately post-downhill backward walking (P = 0.019). There were increases in Achilles tendon aponeurosis stiffness at 24-h post-downhill backward walking (307 ± 179.6 N · mm(-1), P = 0.004), and decreases in Achilles tendon aponeurosis strain during maximum voluntary contraction at 24 (3.8 ± 1.7%, P = 0.008) and 48 h (3.9 ± 1.8%, P = 0.002) post. Repeated cyclical loading of downhill backwards walking affects the behaviour of the muscle-tendon unit, most likely by altering muscle compliance, and these changes result in tendon stiffness increases.

  20. The interfascicular matrix enables fascicle sliding and recovery in tendon, and behaves more elastically in energy storing tendons.

    PubMed

    Thorpe, Chavaunne T; Godinho, Marta S C; Riley, Graham P; Birch, Helen L; Clegg, Peter D; Screen, Hazel R C

    2015-12-01

    While the predominant function of all tendons is to transfer force from muscle to bone and position the limbs, some tendons additionally function as energy stores, reducing the cost of locomotion. Energy storing tendons experience extremely high strains and need to be able to recoil efficiently for maximum energy storage and return. In the equine forelimb, the energy storing superficial digital flexor tendon (SDFT) has much higher failure strains than the positional common digital extensor tendon (CDET). However, we have previously shown that this is not due to differences in the properties of the SDFT and CDET fascicles (the largest tendon subunits). Instead, there is a greater capacity for interfascicular sliding in the SDFT which facilitates the greater extensions in this particular tendon (Thorpe et al., 2012). In the current study, we exposed fascicles and interfascicular matrix (IFM) from the SDFT and CDET to cyclic loading followed by a test to failure. The results show that IFM mechanical behaviour is not a result of irreversible deformation, but the IFM is able to withstand cyclic loading, and is more elastic in the SDFT than in the CDET. We also assessed the effect of ageing on IFM properties, demonstrating that the IFM is less able to resist repetitive loading as it ages, becoming stiffer with increasing age in the SDFT. These results provide further indications that the IFM is important for efficient function in energy storing tendons, and age-related alterations to the IFM may compromise function and predispose older tendons to injury. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  1. Tendon neuroplastic training: changing the way we think about tendon rehabilitation: a narrative review

    PubMed Central

    Rio, Ebonie; Kidgell, Dawson; Moseley, G Lorimer; Docking, Sean; Purdam, Craig; Cook, Jill

    2016-01-01

    Tendinopathy can be resistant to treatment and often recurs, implying that current treatment approaches are suboptimal. Rehabilitation programmes that have been successful in terms of pain reduction and return to sport outcomes usually include strength training. Muscle activation can induce analgesia, improving self-efficacy associated with reducing one's own pain. Furthermore, strength training is beneficial for tendon matrix structure, muscle properties and limb biomechanics. However, current tendon rehabilitation may not adequately address the corticospinal control of the muscle, which may result in altered control of muscle recruitment and the consequent tendon load, and this may contribute to recalcitrance or symptom recurrence. Outcomes of interest include the effect of strength training on tendon pain, corticospinal excitability and short interval cortical inhibition. The aims of this concept paper are to: (1) review what is known about changes to the primary motor cortex and motor control in tendinopathy, (2) identify the parameters shown to induce neuroplasticity in strength training and (3) align these principles with tendon rehabilitation loading protocols to introduce a combination approach termed as tendon neuroplastic training. Strength training is a powerful modulator of the central nervous system. In particular, corticospinal inputs are essential for motor unit recruitment and activation; however, specific strength training parameters are important for neuroplasticity. Strength training that is externally paced and akin to a skilled movement task has been shown to not only reduce tendon pain, but modulate excitatory and inhibitory control of the muscle and therefore, potentially tendon load. An improved understanding of the methods that maximise the opportunity for neuroplasticity may be an important progression in how we prescribe exercise-based rehabilitation in tendinopathy for pain modulation and potentially restoration of the corticospinal control of the muscle-tendon complex. PMID:26407586

  2. Effect of fiber distribution and realignment on the nonlinear and inhomogeneous mechanical properties of human supraspinatus tendon under longitudinal tensile loading.

    PubMed

    Lake, Spencer P; Miller, Kristin S; Elliott, Dawn M; Soslowsky, Louis J

    2009-12-01

    Tendon exhibits nonlinear stress-strain behavior that may be partly due to movement of collagen fibers through the extracellular matrix. While a few techniques have been developed to evaluate the fiber architecture of other soft tissues, the organizational behavior of tendon under load has not been determined. The supraspinatus tendon (SST) of the rotator cuff is of particular interest for investigation due to its complex mechanical environment and corresponding inhomogeneity. In addition, SST injury occurs frequently with limited success in treatment strategies, illustrating the need for a better understanding of SST properties. Therefore, the objective of this study was to quantitatively evaluate the inhomogeneous tensile mechanical properties, fiber organization, and fiber realignment under load of human SST utilizing a novel polarized light technique. Fiber distributions were found to become more aligned under load, particularly during the low stiffness toe-region, suggesting that fiber realignment may be partly responsible for observed nonlinear behavior. Fiber alignment was found to correlate significantly with mechanical parameters, providing evidence for strong structure-function relationships in tendon. Human SST exhibits complex, inhomogeneous mechanical properties and fiber distributions, perhaps due to its complex loading environment. Surprisingly, histological grade of degeneration did not correlate with mechanical properties.

  3. Changes in Achilles tendon mechanical properties following eccentric heel drop exercise are specific to the free tendon.

    PubMed

    Obst, S J; Newsham-West, R; Barrett, R S

    2016-04-01

    Mechanical loading of the Achilles tendon during isolated eccentric contractions could induce immediate and region-dependent changes in mechanical properties. Three-dimensional ultrasound was used to examine the immediate effect of isolated eccentric exercise on the mechanical properties of the distal (free tendon) and proximal (gastrocnemii) regions of the Achilles tendon. Participants (n = 14) underwent two testing sessions in which tendon measurements were made at rest and during a 30% and 70% isometric plantar flexion contractions immediately before and after either: (a) 3 × 15 eccentric heel drops or (b) 10-min rest. There was a significant time-by-session interaction for free tendon length and strain for all loading conditions (P < 0.05). Pairwise comparisons revealed a significant increase in free tendon length and strain at all contraction intensities after eccentric exercise (P < 0.05). There was no significant time-by-session interaction for the gastrocnemii (medial or lateral) aponeurosis or tendon for any of the measured parameters. Immediate changes in Achilles tendon mechanical properties were specific to the free tendon and consistent with changes due to mechanical creep. These findings suggest that the mechanical properties of the free tendon may be more vulnerable to change with exercise compared with the gastrocnemii aponeurosis or tendon. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Clinics in diagnostic imaging (164). Morel-Lavallée lesion.

    PubMed

    Cheong, Sook Chuei Wendy; Wong, Bak Siew Steven

    2016-01-01

    A 31-year-old male motorcyclist presented with prepatellar swelling of the left knee after a collision with a car. Magnetic resonance imaging of the knee showed no bony or ligamentous injury to the knee. Instead, a well-defined, thin-walled, T2-weighted hyperintense fluid collection with internal septations was identified in a prefascial location overlying the left patella and patellar tendon. The findings were in keeping with those of a Morel-Lavallée lesion, a closed internal degloving injury. Morel-Lavallée lesions are occasionally encountered after a blunt soft-tissue trauma. The presentation and imaging features are discussed. Copyright © Singapore Medical Association.

  5. Double incision iso-anatomical ACL reconstruction: the freedom to place the femoral tunnel within the anatomical attachment site without exception.

    PubMed

    Arnold, Markus P; Duthon, Victoria; Neyret, Philippe; Hirschmann, Michael T

    2013-02-01

    The present paper describes the rationale behind the surgical technique and the clinical results of the iso-anatomical, single bundle bone patellar-tendon bone anterior cruciate ligament (ACL) reconstruction. Using a second incision on the distal lateral femur an outside-in femoral tunnel is drilled. Guided by a special aiming device it is possible to place the femoral tunnel in the centre of the ACL footprint in every single case. Since every crucial step of the procedure is under visual control, the technique is safe and reliable, which is mirrored by good clinical results.

  6. Mechanical Control of Myotendinous Junction Formation and Tendon Differentiation during Development.

    PubMed

    Valdivia, Mauricio; Vega-Macaya, Franco; Olguín, Patricio

    2017-01-01

    The development of the musculoskeletal system is a great model to study the interplay between chemical and mechanical inter-tissue signaling in cell adhesion, tissue morphogenesis and differentiation. In both vertebrates and invertebrates (e.g., Drosophila melanogaster ) the formation of muscle-tendon interaction generates mechanical forces which are required for myotendinous junction maturation and tissue differentiation. In addition, these forces must be withstood by muscles and tendons in order to prevent detachment from each other, deformation or even losing their integrity. Extracellular matrix remodeling at the myotendinous junction is key to resist mechanical load generated by muscle contraction. Recent evidences in vertebrates indicate that mechanical forces generated during junction formation regulate chemical signaling leading to extracellular matrix remodeling, however, the mechanotransduction mechanisms associated to this response remains elusive. In addition to extracellular matrix remodeling, the ability of Drosophila tendon-cells to bear mechanical load depends on rearrangement of tendon cell cytoskeleton, thus studying the molecular mechanisms involved in this process is critical to understand the contribution of mechanical forces to the development of the musculoskeletal system. Here, we review recent findings regarding the role of chemical and mechanical signaling in myotendinous junction formation and tendon differentiation, and discuss molecular mechanisms of mechanotransduction that may allow tendon cells to withstand mechanical load during development of the musculoskeletal system.

  7. Fibrocartilage in tendons and ligaments — an adaptation to compressive load

    PubMed Central

    BENJAMIN, M.; RALPHS, J. R.

    1998-01-01

    Where tendons and ligaments are subject to compression, they are frequently fibrocartilaginous. This occurs at 2 principal sites: where tendons (and sometimes ligaments) wrap around bony or fibrous pulleys, and in the region where they attach to bone, i.e. at their entheses. Wrap-around tendons are most characteristic of the limbs and are commonly wider at their point of bony contact so that the pressure is reduced. The most fibrocartilaginous tendons are heavily loaded and permanently bent around their pulleys. There is often pronounced interweaving of collagen fibres that prevents the tendons from splaying apart under compression. The fibrocartilage can be located within fascicles, or in endo- or epitenon (where it may protect blood vessels from compression or allow fascicles to slide). Fibrocartilage cells are commonly packed with intermediate filaments which could be involved in transducing mechanical load. The ECM often contains aggrecan which allows the tendon to imbibe water and withstand compression. Type II collagen may also be present, particularly in tendons that are heavily loaded. Fibrocartilage is a dynamic tissue that disappears when the tendons are rerouted surgically and can be maintained in vitro when discs of tendon are compressed. Finite element analyses provide a good correlation between its distribution and levels of compressive stress, but at some locations fibrocartilage is a sign of pathology. Enthesis fibrocartilage is most typical of tendons or ligaments that attach to the epiphyses of long bones where it may also be accompanied by sesamoid and periosteal fibrocartilages. It is characteristic of sites where the angle of attachment changes throughout the range of joint movement and it reduces wear and tear by dissipating stress concentration at the bony interface. There is a good correlation between the distribution of fibrocartilage within an enthesis and the levels of compressive stress. The complex interlocking between calcified fibrocartilage and bone contributes to the mechanical strength of the enthesis and cartilage-like molecules (e.g. aggrecan and type II collagen) in the ECM contribute to its ability to withstand compression. Pathological changes are common and are known as enthesopathies. PMID:10029181

  8. Biomechanical Analysis of Suture Anchor vs Tenodesis Screw for FHL Transfer.

    PubMed

    Drakos, Mark C; Gott, Michael; Karnovsky, Sydney C; Murphy, Conor I; DeSandis, Bridget A; Chinitz, Noah; Grande, Daniel; Chahine, Nadeen

    2017-07-01

    Chronic Achilles injury is often treated with flexor hallucis longus (FHL) tendon transfer to the calcaneus using 1 or 2 incisions. A single incision avoids the risks of extended dissections yet yields smaller grafts, which may limit fixation options. We investigated the required length of FHL autograft and biomechanical profiles for suture anchor and biotenodesis screw fixation. Single-incision FHL transfer with suture anchor or biotenodesis screw fixation to the calcaneus was performed on 20 fresh cadaveric specimens. Specimens were cyclically loaded until maximal load to failure. Length of FHL tendon harvest, ultimate load, stiffness, and mode of failure were recorded. Tendon harvest length needed for suture anchor fixation was 16.8 ± 2.1 mm vs 29.6 ± 2.4 mm for biotenodesis screw ( P = .002). Ultimate load to failure was not significantly different between groups. A significant inverse correlation existed between failure load and donor age when all specimens were pooled (ρ = -0.49, P < .05). Screws in younger specimens (fewer than 70) resulted in significantly greater failure loads ( P < .03). No difference in stiffness was found between groups. Modes of failure for screw fixation were either tunnel pullout (n = 6) or tendon rupture (n = 4). Anchor failure occurred mostly by suture breakage (n = 8). Adequate FHL tendon length could be harvested through a single posterior incision for fixation to the calcaneus with either fixation option, but suture anchor required significantly less graft length. Stiffness, fixation strength, and load to failure were comparable between groups. An inverse correlation existed between failure load and donor age. Younger specimens with screw fixation demonstrated significantly greater failure loads. Adequate harvest length for FHL transfer could be achieved with a single posterior incision. There was no difference in strength of fixation between suture anchor and biotenodesis screw.

  9. Eccentric exercise: acute and chronic effects on healthy and diseased tendons.

    PubMed

    Kjaer, Michael; Heinemeier, Katja M

    2014-06-01

    Eccentric exercise can influence tendon mechanical properties and matrix protein synthesis. mRNA for collagen and regulatory factors thereof are upregulated in animal tendons, independent of muscular contraction type, supporting the view that tendon, compared with skeletal muscle, is less sensitive to differences in type and/or amount of mechanical stimulus with regard to expression of collagen, regulatory factors for collagen, and cross-link regulators. In overused (tendinopathic) human tendon, eccentric exercise training has a beneficial effect, but the mechanism by which this is elicited is unknown, and slow concentric loading appears to have similar beneficial effects. It may be that tendinopathic regions, as long as they are subjected to a certain magnitude of load at a slow speed, independent of whether this is eccentric or concentric in nature, can reestablish their normal tendon fibril alignment and cell morphology. Copyright © 2014 the American Physiological Society.

  10. Tendon transfer fixation: comparing a tendon to tendon technique vs. bioabsorbable interference-fit screw fixation.

    PubMed

    Sabonghy, Eric Peter; Wood, Robert Michael; Ambrose, Catherine Glauber; McGarvey, William Christopher; Clanton, Thomas Oscar

    2003-03-01

    Tendon transfer techniques in the foot and ankle are used for tendon ruptures, deformities, and instabilities. This fresh cadaver study compares the tendon fixation strength in 10 paired specimens by performing a tendon to tendon fixation technique or using 7 x 20-25 mm bioabsorbable interference-fit screw tendon fixation technique. Load at failure of the tendon to tendon fixation method averaged 279N (Standard Deviation 81N) and the bioabsorbable screw 148N (Standard Deviation 72N) [p = 0.0008]. Bioabsorbable interference-fit screws in these specimens show decreased fixation strength relative to the traditional fixation technique. However, the mean bioabsorbable screw fixation strength of 148N provides physiologic strength at the tendon-bone interface.

  11. Tension Regulation at the Suture Lines for Repair of Neglected Achilles Tendon Laceration.

    PubMed

    Massoud, Elsayed Ibraheem Elsayed

    2017-03-01

    Operative intervention is the preferred option for management of the neglected laceration of the Achilles tendon. However, the commonly used techniques rarely follow the principles of the regenerative medicine for the restoration of the lost tissue. This study postulated that incorporation of the autogenous tendon graft would properly progress when the interplay between mechanical loading and healing phases was correctly applied. A prospective study included 15 patients who were treated for neglected Achilles tendon laceration using the technique of lengthening of the proximal tendon stump. An absorbable reinforcement suture was used for control of the mechanical environment at the suture lines. By an average 5 years of the prospective follow-up, all the repaired tendons had restored continuity and length. The calf circumference equalized to the uninjured side in 12 patients. However, 3 patients had calf atrophy but they improved compared to the preoperative measurements. Sonogram confirmed the restoration of the normal thickness and the gliding characteristics of the repaired tendon. The technique restored continuity and tension of the repaired tendon, preserved the calf circumference, and prevented peritendinous adhesions. The absorbable reinforcement suture spontaneously allowed for the mechanical loading of the grafted tendon. Level IV, case series.

  12. The effect of foot strike pattern on achilles tendon load during running.

    PubMed

    Almonroeder, Thomas; Willson, John D; Kernozek, Thomas W

    2013-08-01

    In this study we compared Achilles tendon loading parameters during barefoot running among females with different foot strike patterns using open-source computer muscle modeling software to provide dynamic simulations of running. Muscle forces of the gastrocnemius and soleus were estimated from experimental data collected in a motion capture laboratory during barefoot running for 11 runners utilizing a rearfoot strike (RFS) and 8 runners utilizing a non-RFS (NRFS) pattern. Our results show that peak Achilles tendon force occurred earlier in stance phase (p = 0.007), which contributed to a 15% increase in average Achilles tendon loading rate among participants adopting a NRFS pattern (p = 0.06). Stance time, step length, and the estimated number of steps per mile were similar between groups. However, runners with a NRFS pattern experienced 11% greater Achilles tendon impulse each step (p = 0.05) and nearly significantly greater Achilles tendon impulse per mile run (p = 0.06). This difference equates to an additional 47.7 body weights for each mile run with a NRFS pattern. Runners considering a NRFS pattern may want to account for these novel stressors and adapt training programs accordingly.

  13. Effect of Immediate and Delayed High-Strain Loading on Tendon-to-Bone Healing After Anterior Cruciate Ligament Reconstruction

    PubMed Central

    Packer, Jonathan D.; Bedi, Asheesh; Fox, Alice J.; Gasinu, Selom; Imhauser, Carl W.; Stasiak, Mark; Deng, Xiang-Hua; Rodeo, Scott A.

    2014-01-01

    Background: We previously demonstrated, in a rat anterior cruciate ligament (ACL) graft reconstruction model, that the delayed application of low-magnitude-strain loading resulted in improved tendon-to-bone healing compared with that observed after immediate loading and after prolonged immobilization. The purpose of this study was to determine the effect of higher levels of strain loading on tendon-to-bone healing. Methods: ACL reconstruction was carried out in a rat model in three randomly assigned groups: high-strain daily loading beginning on either (1) postoperative day one (immediate-loading group; n = 7) or (2) postoperative day four (delayed-loading group; n = 11) or (3) after prolonged immobilization (immobilized group; n = 8). Animals were killed two weeks after surgery and micro-computed tomography (micro-CT) and biomechanical testing of the bone-tendon-bone complex were carried out. Results: The delayed-loading group had greater tissue mineral density than either the immediate-loading or immobilized group (mean [and standard deviation], 813.0 ± 24.9 mg/mL compared with 778.4 ± 32.6 mg/mL and 784.9 ± 26.4 mg/mL, respectively; p < 0.05). There was a trend toward greater bone volume per total volume fraction in both the immobilized and the delayed-loading group compared with the immediate-loading group (0.24 ± 0.03 and 0.23 ± 0.06 compared with 0.20 ± 0.05; p = 0.06). Trabecular thickness was greater in the immobilized group compared with the immediate-loading group (106.5 ± 23.0 μm compared with 72.6 ± 10.6 μm; p < 0.01). There were no significant differences in failure load or stiffness between the immobilized group and either high-strain cyclic-loading group. Conclusions: Immediate application of high-strain loading appears to have a detrimental effect on healing in this rat model. Any beneficial effects of delayed loading on the healing tendon-bone interface (after a brief period of immobilization) may be offset by the detrimental effects of excessive strain levels or by the detrimental effects of stress deprivation on the graft. Clinical Relevance: The timing and magnitude of mechanical load on a healing rat ACL reconstruction graft may have important implications for postoperative rehabilitation. Avoidance of exercises that cause high graft strain in the early postoperative period may lead to improved tendon-to-bone healing in humans. PMID:24806014

  14. Enhanced tendon-to-bone repair through adhesive films.

    PubMed

    Linderman, Stephen W; Golman, Mikhail; Gardner, Thomas R; Birman, Victor; Levine, William N; Genin, Guy M; Thomopoulos, Stavros

    2018-04-01

    Tendon-to-bone surgical repairs have unacceptably high failure rates, possibly due to their inability to recreate the load transfer mechanisms of the native enthesis. Instead of distributing load across a wide attachment footprint area, surgical repairs concentrate shear stress on a small number of suture anchor points. This motivates development of technologies that distribute shear stresses away from suture anchors and across the enthesis footprint. Here, we present predictions and proof-of-concept experiments showing that mechanically-optimized adhesive films can mimic the natural load transfer mechanisms of the healthy attachment and increase the load tolerance of a repair. Mechanical optimization, based upon a shear lag model corroborated by a finite element analysis, revealed that adhesives with relatively high strength and low stiffness can, theoretically, strengthen tendon-to-bone repairs by over 10-fold. Lap shear testing using tendon and bone planks validated the mechanical models for a range of adhesive stiffnesses and strengths. Ex vivo human supraspinatus repairs of cadaveric tissues using multipartite adhesives showed substantial increase in strength. Results suggest that adhesive-enhanced repair can improve repair strength, and motivate a search for optimal adhesives. Current surgical techniques for tendon-to-bone repair have unacceptably high failure rates, indicating that the initial repair strength is insufficient to prevent gapping or rupture. In the rotator cuff, repair techniques apply compression over the repair interface to achieve contact healing between tendon and bone, but transfer almost all force in shear across only a few points where sutures puncture the tendon. Therefore, we evaluated the ability of an adhesive film, implanted between tendon and bone, to enhance repair strength and minimize the likelihood of rupture. Mechanical models demonstrated that optimally designed adhesives would improve repair strength by over 10-fold. Experiments using idealized and clinically-relevant repairs validated these models. This work demonstrates an opportunity to dramatically improve tendon-to-bone repair strength using adhesive films with appropriate material properties. Copyright © 2018 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  15. A biomechanical comparison of tendon-bone interface motion and cyclic loading between single-row, triple-loaded cuff repairs and double-row, suture-tape cuff repairs using biocomposite anchors.

    PubMed

    Barber, F Alan; Drew, Otis R

    2012-09-01

    To compare tendon-bone interface motion and cyclic loading in a single-row, triple-loaded anchor repair with a suture-tape, rip-stop, double-row rotator cuff repair. Using 18 human shoulders from 9 matched cadaveric pairs, we created 2 groups of rotator cuff repairs. Group 1 was a double-row, rip-stop, suture-tape construct. Group 2 was a single-row, triple-loaded construct. Before mechanical testing, the supraspinatus footprint was measured with calipers. A superiorly positioned digital camera optically measured the tendon footprint motion during 60° of humeral internal and external rotation. Specimens were secured at a fixed angle not exceeding 45° in reference to the load. After preloading, each sample was cycled between 10 N and 100 N for 200 cycles at 1 Hz, followed by destructive testing at 33 mm/s. A digital camera with tracking software measured the repair displacement at 100 and 200 cycles. Ultimate load and failure mode for each sample were recorded. The exposed anterior footprint border (6.5% ± 6%) and posterior footprint border (0.9% ± 1.7%) in group 1 were statistically less than the exposed anterior footprint border (30.3% ± 17%) and posterior footprint border (29.8% ± 14%) in group 2 (P = .003 and P < .001, respectively). The maximal internal rotation and external rotation tendon footprint displacements in group 1 (1.6 mm and 1.4 mm, respectively) were less than those in group 2 (both 3.6 mm) (P = .007 and P = .004, respectively). Mean displacement after 100 cycles for group 1 and group 2 was 2.0 mm and 3.2 mm, respectively, and at 200 cycles, mean displacement was 2.5 mm and 4.2 mm, respectively (P = .02). The mean ultimate failure load in group 1 (586 N) was greater than that in group 2 (393 N) (P = .02). The suture-tendon interface was the site of most construct failures. The suture-tape, rip-stop, double-row rotator cuff repair had greater footprint coverage, less rotational footprint displacement, and a greater mean ultimate failure load than the triple-loaded, single-row repair on mechanical testing. No double-row or single-row constructs showed 5 mm of displacement after the first 100 cycles. The most common failure mode for both constructs was suture tearing through the tendon. Differences in cuff fixation influence rotational tendon movement and may influence postoperative healing. Stronger repair constructs still fail at the suture-tendon interface. Copyright © 2012 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  16. Correlation between hindfoot joint three-dimensional kinematics and the changes of the medial arch angle in stage II posterior tibial tendon dysfunction flatfoot.

    PubMed

    Zhang, Yi-Jun; Xu, Jian; Wang, Yue; Lin, Xiang-Jin; Ma, Xin

    2015-02-01

    The aim of this study was to explore the correlation between the kinematics of the hindfoot joint and the medial arch angle change in stage II posterior tibial tendon dysfunction flatfoot three-dimensionally under loading. Computed tomography (CT) scans of 12 healthy feet and 12 feet with stage II posterior tibial tendon dysfunction flatfoot were taken both in non- and full-body-weight-bearing condition. The CT images of the hindfoot bones were reconstructed into three-dimensional models with Mimics and Geomagic reverse engineering software. The three-dimensional changes of the hindfoot joint were calculated to determine their correlation to the medial longitudinal arch angle. The medial arch angle change was larger in stage II posterior tibial tendon dysfunction flatfoot compared to that in healthy foot under loading. The rotation and translation of the talocalcaneal joint, the talonavicular joint and the calcanocuboid joint had little influence on the change of the medial arch angle in healthy foot. However, the eversion of the talocalcaneal joint, the proximal translation of the calcaneus relative to the talus and the dorsiflexion of talonavicular joint could increase the medial arch angle in stage II posterior tibial tendon dysfunction flatfoot under loading. Joint instability occurred in patients with stage II posterior tibial tendon dysfunction flatfoot under loading. Limitation of over movement of the talocalcaneal joint and the talonavicular joint may help correct the medial longitudinal arch in stage II posterior tibial tendon dysfunction flatfoot. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Biomechanical Evaluation of Suture Anchor Versus Transosseous Tunnel Quadriceps Tendon Repair Techniques.

    PubMed

    Sherman, Seth L; Copeland, Marilyn E; Milles, Jeffrey L; Flood, David A; Pfeiffer, Ferris M

    2016-06-01

    To evaluate the biomechanical fixation strength of suture anchor and transosseous tunnel repair of the quadriceps tendon in a standardized cadaveric repair model. Twelve "patella-only" specimens were used. Dual-energy X-ray absorptiometry measurement was performed to ensure equal bone quality amongst groups. Specimens were randomly assigned to either a suture anchor repair of quadriceps tendon group (n = 6) or a transosseous tunnel repair group (n = 6). Suture type and repair configuration were equivalent. After the respective procedures were performed, each patella was mounted into a gripping jig. Tensile load was applied at a rate of 0.1 mm/s up to 100 N after which cyclic loading was applied at a rate of 1 Hz between magnitudes of 50 to 150 N, 50 to 200 N, 50 to 250 N, and tensile load at a rate of 0.1 mm/s until failure. Outcome measures included load to failure, displacement at 1st 100 N load, and displacement after each 10th cycle of loading. The measured cyclic displacement to the first 100 N, 50 to 150 N, 50 to 200 N, and 50 to 250 N was significantly less for suture anchors than transosseous tunnels. There was no statistically significant difference in ultimate load to failure between the 2 groups (P = .40). Failure mode for all suture anchors except one was through the soft tissue. Failure mode for all transosseous specimens but one was pulling the repair through the transosseous tunnel. Suture anchor quadriceps tendon repairs had significantly decreased gapping during cyclic loading, but no statistically significant difference in ultimate load to failure when compared with transosseous tunnel repairs. Although suture anchor quadriceps tendon repair appears to be a biomechanically superior construct, a clinical study is needed to confirm this technique as a viable alternative to gold standard transosseous techniques. Although in vivo studies are needed, these results support the suture anchor technique as a viable alternative to transosseous repair of the quadriceps tendon. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  18. Informing Stem Cell-Based Tendon Tissue Engineering Approaches with Embryonic Tendon Development.

    PubMed

    Okech, William; Kuo, Catherine K

    Adult tendons fail to regenerate normal tissue after injury, and instead form dysfunctional scar tissue with abnormal mechanical properties. Surgical repair with grafts is the current standard to treat injuries, but faces significant limitations including pain and high rates of re-injury. To address this, we aim to regenerate new, normal tendons to replace dysfunctional tendons. A common approach to tendon tissue engineering is to design scaffolds and bioreactors based on adult tendon properties that can direct adult stem cell tenogenesis. Despite significant progress, advances have been limited due, in part, to a need for markers and potent induction cues. Our goal is to develop novel tendon tissue engineering approaches informed by embryonic tendon development. We are characterizing structure-property relationships of embryonic tendon to identify design parameters for three-dimensional scaffolds and bioreactor mechanical loading systems to direct adult stem cell tenogenesis. We will review studies in which we quantified changes in the mechanical and biochemical properties of tendon during embryonic development and elucidated specific mechanisms of functional property elaboration. We then examined the effects of these mechanical and biochemical factors on embryonic tendon cell behavior. Using custom-designed bioreactors, we also examined the effects of dynamic mechanical loading and growth factor treatment on embryonic tendon cells. Our findings have established cues to induce tenogenesis as well as metrics to evaluate differentiation. We finish by discussing how we have evaluated the tenogenic differentiation potential of adult stem cells by comparing their responses to that of embryonic tendon cells in these culture systems.

  19. The V-Shaped Distal Triceps Tendon Repair: A Comparative Biomechanical Analysis.

    PubMed

    Scheiderer, Bastian; Imhoff, Florian B; Morikawa, Daichi; Lacheta, Lucca; Obopilwe, Elifho; Cote, Mark P; Imhoff, Andreas B; Mazzocca, Augustus D; Siebenlist, Sebastian

    2018-05-01

    Restoring footprint anatomy, minimizing gap formation, and maximizing the strength of distal triceps tendon repairs are essential factors for a successful healing process and return to sport. The novel V-shaped distal triceps tendon repair technique with unicortical button fixation closely restores footprint anatomy, provides minimal gap formation and high ultimate failure load, and minimizes iatrogenic fracture risk in acute/subacute distal triceps tendon tears. Controlled laboratory study. Twenty-four cadaveric elbows (mean ± SD age, 66 ± 5 years) were randomly assigned to 1 of 3 repair groups: the transosseous cruciate repair technique (gold standard), the knotless suture-bridge repair technique, and the V-shaped distal triceps tendon repair technique. Anatomic measurements of the central triceps tendon footprint were obtained in all specimens with a 3-dimensional digitizer before and after the repair. Cyclic loading was performed for a total of 1500 cycles at a rate of 0.25 Hz, pulling in the direction of the triceps. Displacements were measured on the medial and lateral tendon sites with 2 differential variable reluctance transducers. Load to failure and construct failure mode were recorded. The mean triceps bony insertion area was 399.05 ± 81.23 mm 2 . The transosseous cruciate repair technique restored 36.6% ± 16.8% of the native tendon insertion area, which was significantly different when compared with the knotless suture-bridge repair technique (85.2% ± 14.8%, P = .001) and the V-shaped distal triceps tendon repair technique (88.9% ± 14.8%, P = .002). Mean displacement showed no significant difference between the V-shaped distal triceps tendon repair technique (medial side, 0.75 ± 0.56 mm; lateral side, 0.99 ± 0.59 mm) and the knotless suture-bridge repair technique (1.61 ± 0.97 mm and 1.29 ± 0.8 mm) but significance between the V-shaped distal triceps tendon repair technique and the transosseous cruciate repair technique (4.91 ± 1.12 mm and 5.78 ± 0.9 mm, P < .001). Mean peak failure load of the V-shaped distal triceps tendon repair technique (732.1 ± 156.0 N) was significantly higher than that of the knotless suture-bridge repair technique (505.4 ± 173.9 N, P = .011) and the transosseous cruciate repair technique (281.1 ± 74.8 N, P < .001). Mechanism of failure differed among the 3 repairs, with the only olecranon fracture occurring in the knotless suture-bridge repair technique at the level of the lateral row suture anchors. At time zero, the V-shaped distal triceps tendon repair technique and the knotless suture-bridge repair technique both provided anatomic footprint coverage. Ultimate load to failure was highest for the V-shaped distal triceps tendon repair technique, while gap formation was different only in comparison with the transosseous cruciate repair technique. The V-shaped distal triceps tendon repair technique provides an alternative procedure to other established repairs for acute/subacute distal triceps tendon ruptures. The reduced repair site motion of the V-shaped distal triceps tendon repair technique and the knotless suture-bridge repair technique at the time of surgery may allow a more aggressive rehabilitation program in the early postoperative period.

  20. Computational Modelling of Patella Femoral Kinematics During Gait Cycle and Experimental Validation

    NASA Astrophysics Data System (ADS)

    Maiti, Raman

    2016-06-01

    The effect of loading and boundary conditions on patellar mechanics is significant due to the complications arising in patella femoral joints during total knee replacements. To understand the patellar mechanics with respect to loading and motion, a computational model representing the patella femoral joint was developed and validated against experimental results. The computational model was created in IDEAS NX and simulated in MSC ADAMS/VIEW software. The results obtained in the form of internal external rotations and anterior posterior displacements for a new and experimentally simulated specimen for patella femoral joint under standard gait condition were compared with experimental measurements performed on the Leeds ProSim knee simulator. A good overall agreement between the computational prediction and the experimental data was obtained for patella femoral kinematics. Good agreement between the model and the past studies was observed when the ligament load was removed and the medial lateral displacement was constrained. The model is sensitive to ±5 % change in kinematics, frictional, force and stiffness coefficients and insensitive to time step.

  1. Computational Modelling of Patella Femoral Kinematics During Gait Cycle and Experimental Validation

    NASA Astrophysics Data System (ADS)

    Maiti, Raman

    2018-06-01

    The effect of loading and boundary conditions on patellar mechanics is significant due to the complications arising in patella femoral joints during total knee replacements. To understand the patellar mechanics with respect to loading and motion, a computational model representing the patella femoral joint was developed and validated against experimental results. The computational model was created in IDEAS NX and simulated in MSC ADAMS/VIEW software. The results obtained in the form of internal external rotations and anterior posterior displacements for a new and experimentally simulated specimen for patella femoral joint under standard gait condition were compared with experimental measurements performed on the Leeds ProSim knee simulator. A good overall agreement between the computational prediction and the experimental data was obtained for patella femoral kinematics. Good agreement between the model and the past studies was observed when the ligament load was removed and the medial lateral displacement was constrained. The model is sensitive to ±5 % change in kinematics, frictional, force and stiffness coefficients and insensitive to time step.

  2. Mid-term development of hamstring tendon length and velocity after distal femoral extension osteotomy in children with bilateral cerebral palsy: a retrospective cohort study.

    PubMed

    Salami, Firooz; Wagner, Julia; van Drongelen, Stefan; Klotz, Matthias C M; Dreher, Thomas; Wolf, Sebastian I; Niklasch, Mirjam

    2018-03-14

    Flexed knee gait can be treated with distal femoral extension osteotomy (DFEO) and additional patellar tendon advancement (PTA) in children with cerebral palsy (CP). This study assesses changes in hamstring muscle tendon length (MTL) and velocity after DFEO (+PTA). Nineteen children (mean age 13y [standard deviation 3y] at surgery) with CP and flexed knee gait who were treated with DFEO (15 limbs) or DFEO+PTA (10 limbs) were retrospectively included in this study. Gait analyses were performed preoperatively (E0), 1 year postoperatively (E1), and for 10 limbs additionally 2 to 5 years postoperatively (E2). Hamstring MTL and velocities were assessed at all examination dates using OpenSim. Hamstring MTL and velocity did not change significantly over time. From E0 to E1, knee flexion in stance improved for both DFEO and DFEO+PTA (p<0.05), knee flexion in swing only improved after DFEO+PTA (p<0.05). The improved knee flexion in stance and swing was maintained at E2. DFEO led to a significant improvement in knee kinematics at E1 which was maintained at E2. DFEO seems to prevent recurrent hamstring tightness but does not lead to lengthened or fastened hamstrings. Distal femoral extension osteotomy (DFEO) does not change hamstring muscle tendon length. DFEO does not change hamstring lengthening velocity. DFEO leads to a significant improvement in knee kinematics. Changes in knee kinematics after DFEO can be maintained at mid-term. DFEO seems to prevent recurrent hamstring tightness. © 2018 Mac Keith Press.

  3. Button fixation technique for Achilles tendon reinsertion: a biomechanical study.

    PubMed

    Awogni, David; Chauvette, Guillaume; Lemieux, Marie-Line; Balg, Frédéric; Langelier, Ève; Allard, Jean-Pascal

    2014-01-01

    Chronic insertional tendinopathy of the Achilles tendon is a frequent and disabling pathologic entity. Operative treatment is indicated for patients for whom nonoperative management has failed. The treatment can consist of the complete detachment of the tendon insertion and extensive debridement. We biomechanically tested a new operative technique that uses buttons for fixation of the Achilles tendon insertion on the posterior calcaneal tuberosity and compared it with 2 standard bone anchor techniques. A total of 40 fresh-frozen cadaver specimens were used to compare 3 fixation techniques for reinserting the Achilles tendon: single row anchors, double row anchors, and buttons. The ultimate loads and failure mechanisms were recorded. The button assembly (median load 764 N, range 713 to 888) yielded a median fixation strength equal to 202% (range 137% to 251%) of that obtained with the double row anchors (median load 412 N, range 301 to 571) and 255% (range 213% to 317%) of that obtained with the single row anchors (median load 338 N, range 241 to 433N). The most common failure mechanisms were suture breakage with the buttons (55%) and pull out of the implant with the double row (70%) and single row (85%) anchors. The results of the present biomechanical cadaver study have shown that Achilles tendon reinsertion fixation using the button technique provides superior pull out strength than the bone anchors tested. Copyright © 2014 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  4. Running shoes increase achilles tendon load in walking: an acoustic propagation study.

    PubMed

    Wearing, Scott C; Reed, Lloyd; Hooper, Sue L; Bartold, Simon; Smeathers, James E; Brauner, Torsten

    2014-08-01

    Footwear remains a prime candidate for the prevention and rehabilitation of Achilles tendinopathy because it is thought to decrease tension in the tendon through elevation of the heel. However, evidence for this effect is equivocal. This study used an acoustic transmission technique to investigate the effect of running shoes on Achilles tendon loading during barefoot and shod walking. Acoustic velocity was measured in the Achilles tendon of 12 recreationally active males (age, 31 ± 9 yr; height, 1.78 ± 0.06 m; weight, 81.0 ± 16.9 kg) during barefoot and shod walking at matched self-selected speed (3.4 ± 0.7 km·h). Standard running shoes incorporating a 10-mm heel offset were used. Vertical ground reaction force and spatiotemporal parameters were determined with an instrumented treadmill. Axial acoustic velocity in the Achilles tendon was measured using a custom-built ultrasonic device. All data were acquired at a rate of 100 Hz during 10 s of steady-state walking. Statistical comparisons between barefoot and shod conditions were made using paired t-tests and repeated-measure ANOVA. Acoustic velocity in the Achilles tendon was highly reproducible and was typified by two maxima (P1, P2) and minima (M1, M2) during walking. Footwear resulted in a significant increase in step length, stance duration, and peak vertical ground reaction force compared with barefoot walking. Peak acoustic velocity in the Achilles tendon (P1, P2) was significantly higher with running shoes. Peak acoustic velocity in the Achilles tendon was higher with footwear, suggesting that standard running shoes with a 10-mm heel offset increase tensile load in the Achilles tendon. Although further research is required, these findings question the therapeutic role of standard running shoes in Achilles tendinopathy.

  5. [Evidence-based therapy for tendinopathy of the knee joint : Which forms of therapy are scientifically proven?

    PubMed

    Horstmann, H; Clausen, J D; Krettek, C; Weber-Spickschen, T S

    2017-03-01

    Tendinopathy in the region of the knee joint is a common pathological disorder. People active in sports, in particular, have a high probability of suffering from tendinopathy. Despite its high clinical relevance, the level of evidence of therapy options for tendinopathy in the knee region differs greatly. This review gives an overview of current evidence levels for therapy options in tendinopathy of the quadriceps, patellar and pes anserinus insertion tendons as well as of the distal iliotibial tract tendon. The treatment with platelet-rich plasma showed a significantly better outcome when used correctly and treatment with shock waves, operative treatment and sclerotherapy have also shown positive effects. Treatment with corticosteroid injections and with oral non-steroidal anti-inflammatory drugs (NSAID) showed positive short-term effects (follow-up ±4 weeks). No reasonable data are available for the treatment of tendinopathy in the knee region by acupuncture, fascial therapy or cryotherapy. The use of kinesio taping showed no significant relief from complaints compared with standard conservative treatment. The use of multimodal therapy without evidence is, therefore, particularly common in elite athletes.

  6. Lacertus Fibrosus Versus Achilles Allograft Reconstruction for Distal Biceps Tears: A Biomechanical Study.

    PubMed

    Murthi, Anand M; Ramirez, Miguel A; Parks, Brent G; Carpenter, Shannon R

    2017-12-01

    The bicipital aponeurosis, or lacertus fibrosus, can potentially be used as a reconstruction graft in chronic distal biceps tendon tears. To evaluate construct stiffness, load to failure, and failure mechanism with lacertus fibrosus versus Achilles allograft for distal biceps tendon reconstruction. Controlled laboratory study. Ten fresh-frozen matched cadaveric pairs of elbows were used. Three centimeters of the distal biceps tendon was resected. Specimens were randomized to the lacertus fibrosus or Achilles tendon group. In one group, the lacertus fibrosus was released from its distal attachment and then tubularized and repaired intraosseously to the radius. In the other group, an Achilles tendon graft was sutured to the biceps muscle and repaired to the ulna. The prepared radii were rigidly mounted at a 45° angle on a load frame. The proximal biceps muscle was secured in a custom-fabricated cryogenic grip. Displacement was measured using a differential variable reluctance transducer mounted at the radius-soft tissue junction and in the muscle- or muscle allograft-tissue junction proximal to the repair. Specimens were loaded at 20 mm/min until failure, defined as a 3-mm displacement at the radius-soft tissue junction. No significant difference was found in mean load to failure between the lacertus fibrosus and Achilles tendon group (mean ± SD, 20.2 ± 5.5 N vs 16.89 ± 4.54 N; P = .18). Stiffness also did not differ significantly between the lacertus fibrosus and Achilles tendon group (12.3 ± 7.1 kPa vs 10.5 ± 5.7 kPa; P = .34). The primary mode of failure in the lacertus fibrosus group was suture pullout from the tissue at the musculotendinous junction (7 of 10). In the Achilles group, failures were observed at the muscle-allograft interface (3) and the allograft-bone (radial tuberosity) interface (3), and 3 suture failures were observed. The button fixation did not fail in any specimens. The mean stiffness and load-to-failure values were not significantly different between a lacertus fibrosus construct and Achilles tendon allograft. Use of the lacertus fibrosus may be a potential alternative to Achilles tendon allograft reconstruction of chronic distal biceps tears when primary repair is not possible.

  7. Biomechanical properties of double- and single-row suture anchor repair for surgical treatment of insertional Achilles tendinopathy.

    PubMed

    Beitzel, Knut; Mazzocca, Augustus D; Obopilwe, Elifho; Boyle, James W; McWilliam, James; Rincon, Lina; Dhar, Yasmin; Arciero, Robert A; Amendola, Annunziato

    2013-07-01

    Because of intratendinous ossifications, retrocalcaneal bursitis, or intratendinous necrosis commonly found in insertional tendinosis, it is often necessary to detach the tendon partially or entirely from its tendon-to-bone junction. Double-row repair for insertional Achilles tendinopathy will generate an increased contact area and demonstrate higher biomechanical stability. Controlled laboratory study. Eighteen cadaver Achilles tendons were split longitudinally and detached, exposing the calcaneus; an ostectomy was performed and the tendon was reattached to the calcaneus in 1 of 2 ways: 2 suture anchors (single row) or a 4-anchor (double row) construct. Footprint area measurements over time, displacement after cyclic loading (2000 cycles), and final load to failure were measured. The double-row refixation technique was statistically superior to the single-row technique in footprint area measurement initially and 5 minutes after repair (P = .009 and P = .01, respectively) but not after 24 hours (P = .713). The double-row construct demonstrated significantly improved measures for peak load (433.9 ± 84.3 N vs 212.0 ± 49.7 N; P = .042), load at yield (354.7 ± 106.2 N vs 198.7 ± 39.5 N; P = .01), and slope (51.8 ± 9.9 N/mm vs 66.7 ± 16.2 N/mm; P = .021). Cyclic loading did not demonstrate significant differences between the 2 constructs. Double-row construct for reinsertion of a completely detached Achilles tendon using proximal and distal rows resulted in significantly larger contact area initially and 5 minutes after repair and led to significantly higher peak load to failure on destructive testing. In treatment for insertional Achilles tendinosis, the tendon often has to be detached and anatomically reattached to its insertion at the calcaneus. To our knowledge there is a lack of biomechanical studies supporting either a number or a pattern of suture anchor fixation. Because the stresses going across the insertion site of the Achilles tendon are significant during rehabilitation and weightbearing activities, it is imperative to have a strong construct that allows satisfactory healing during the early postoperative process.

  8. Rat supraspinatus muscle atrophy after tendon detachment.

    PubMed

    Barton, Elisabeth R; Gimbel, Jonathan A; Williams, Gerald R; Soslowsky, Louis J

    2005-03-01

    Rotator cuff tears are one of the most common tendon disorders found in the healthy population. Tendon tears not only affect the biomechanical properties of the tendon, but can also lead to debilitation of the muscles attached to the damaged tendons. The changes that occur in the muscle after tendon detachment are not well understood. A rat rotator cuff model was utilized to determine the time course of changes that occur in the supraspinatus muscle after tendon detachment. It was hypothesized that the lack of load on the supraspinatus muscle would cause a significant decrease in muscle mass and a conversion of muscle fiber properties toward those of fast fiber types. Tendons were detached at the insertion on the humerus without repair. Muscle mass, morphology and fiber properties were measured at one, two, four, eight, and 16 weeks after detachment. Tendon detachment resulted in a rapid loss of muscle mass, an increase in the proportion of fast muscle fibers, and an increase in the fibrotic content of the muscle bed, concomitant with the appearance of adhesions of the tendon to surrounding surfaces. At 16 weeks post-detachment, muscle mass and the fiber properties in the deep muscle layers returned to normal levels. However, the fiber shifts observed in the superficial layers persisted throughout the experiment. These results suggest that load returned to the muscle via adhesions to surrounding surfaces, which may be sufficient to reverse changes in muscle mass.

  9. Extracellular matrix adaptation of tendon and skeletal muscle to exercise

    PubMed Central

    Kjær, Michael; Magnusson, Peter; Krogsgaard, Michael; Møller, Jens Boysen; Olesen, Jens; Heinemeier, Katja; Hansen, Mette; Haraldsson, Bjarki; Koskinen, Satu; Esmarck, Birgitte; Langberg, Henning

    2006-01-01

    The extracellular matrix (ECM) of connective tissues enables linking to other tissues, and plays a key role in force transmission and tissue structure maintenance in tendons, ligaments, bone and muscle. ECM turnover is influenced by physical activity, and both collagen synthesis and metalloprotease activity increase with mechanical loading. This can be shown by determining propeptide and proteinase activity by microdialysis, as well as by verifying the incorporation of infused stable isotope amino acids in biopsies. Local tissue expression and release of growth factors for ECM such as IGF-1, TGF-beta and IL-6 is enhanced following exercise. For tendons, metabolic activity (e.g. detected by positron emission tomography scanning), circulatory responses (e.g. as measured by near-infrared spectroscopy and dye dilution) and collagen turnover are markedly increased after exercise. Tendon blood flow is regulated by cyclooxygenase-2 (COX-2)-mediated pathways, and glucose uptake is regulated by specific pathways in tendons that differ from those in skeletal muscle. Chronic loading in the form of physical training leads both to increased collagen turnover as well as to some degree of net collagen synthesis. These changes modify the mechanical properties and the viscoelastic characteristics of the tissue, decrease its stress-susceptibility and probably make it more load-resistant. The mechanical properties of tendon fascicles vary within a given human tendon, and even show gender differences. The latter is supported by findings of gender-related differences in the activation of collagen synthesis with exercise. These findings may provide the basis for understanding tissue overloading and injury in both tendons and skeletal muscle. PMID:16637870

  10. Fixation of the Achilles tendon insertion using suture button technology.

    PubMed

    Fanter, Nathan J; Davis, Edward W; Baker, Champ L

    2012-09-01

    In the operative treatment of Achilles insertional tendinopathy, no guidelines exist concerning which form of fixation of the Achilles tendon insertion is superior. Transcalcaneal drill pin passage does not place any major plantar structures at risk, and the addition of a Krackow stitch and suture button to the fixation technique provides a significant increase in ultimate load to failure in Achilles tendon insertional repairs. Controlled laboratory study. The Achilles tendon insertions in 6 fresh-frozen cadaveric ankles were detached, and transcalcaneal drill pins were passed. Plantar dissection took place to evaluate the drill pin relationship to the plantar fascia, lateral plantar nerve and artery, flexor digitorum longus tendon, and master knot of Henry. The Achilles tendons were then repaired with a double-row suture anchor construct alone or with a suture button and Krackow stitch added to the double-row suture anchor construct. The repairs were then tested to maximum load to failure at 20 mm/min. The mode of failure was recorded, and the mean maximum load to failure was assessed using the Student t test for distributions with equal variance. Transcalcaneal drill pin passage did not place any selected anatomic structures at risk. The mean maximum load to failure for the suture bridge group was 239.2 N; it was 391.4 N for the group with the suture button (P = .014). The lateral plantar artery was the structure placed at greatest risk from drill pin placement, with a mean distance of 22.7 mm (range, 16.5-29.2 mm) between the pin and artery. In this laboratory study, transcalcaneal drill pin passage appeared to be anatomically safe, and the use of suture button technology with a Krackow stitch for Achilles tendon insertional repair significantly increased repair strength. Achilles tendon insertional repair with suture button fixation and a Krackow stitch may facilitate the earlier institution of postoperative rehabilitation and improve clinical outcomes.

  11. Tibial plateau fracture after anterior cruciate ligament reconstruction: Role of the interference screw resorption in the stress riser effect.

    PubMed

    Thaunat, Mathieu; Nourissat, Geoffroy; Gaudin, Pascal; Beaufils, Philippe

    2006-06-01

    We report a case of tibial plateau fracture after previous anterior cruciate ligament (ACL) reconstruction using patellar tendon autograft and bioabsorbable screws 4 years previously. The fracture occurred through the tibial tunnel. The interference screw had undergone complete resorption and the tunnel widening had increased. The resorption of the interference screw did not simultaneously promote and foster the growth of surrounding bone tissue. Therefore, the area of reactive tissue left by the screw resorption in an enlarged bone tunnel may lead to vulnerability of the tibial plateau. Stress risers would occur following ACL reconstruction if either resorption is not complete or bony integration is not complete.

  12. Abnormal findings on knee magnetic resonance imaging in asymptomatic NBA players.

    PubMed

    Walczak, Brian E; McCulloch, Patrick C; Kang, Richard W; Zelazny, Anthony; Tedeschi, Fred; Cole, Brian J

    2008-01-01

    The purpose of this study was to evaluate the knees of asymptomatic National Basketball Association (NBA) players via magnetic resonance imaging (MRI) and confirm or dispute findings reported in the previous literature. It is thought that a variety of significant abnormalities affecting the knee exist in asymptomatic patients and that these findings can be accurately identified on MRI. Two months prior to the 2005 season, bilateral knee MRI examinations of 14 asymptomatic NBA players (28 knees) were evaluated for abnormalities of the articular cartilage, menisci, and patellar and quadriceps tendons. The presence of joint effusion, subchondral edema, and cystic lesions and the integrity of the collateral and cruciate ligaments were also assessed.

  13. Knotted versus knotless suture bridge repair of the achilles tendon insertion: a biomechanical study.

    PubMed

    Cox, Joseph T; Shorten, Peter L; Gould, Gregory C; Markert, Ronald J; Barnett, Michael D; Laughlin, Richard T

    2014-11-01

    Surgical treatment of insertional Achilles tendinopathy often involves detachment and debridement of the Achilles tendon insertion. A recent study has shown that knotted suture bridge fixation of the Achilles to the calcaneus is biomechanically superior to single-row fixation, but there is an absence of literature on the use of different suture bridge constructs to repair the Achilles tendon. There will be no significant difference in the load to failure, mode of failure, tendon strain, tendon stiffness, repair site gapping, or footprint size when comparing knotted suture bridge repair to knotless suture bridge repair of the Achilles tendon after detachment for insertional Achilles tendinopathy. Controlled laboratory study. A single specimen from each pair of 10 cadaveric Achilles tendons was randomized to 1 of 2 Achilles insertion repair groups: knotted (n = 10) or knotless (n = 10) suture bridge repair. Repaired footprint size was measured, and then cyclic testing from 10 to 100 N for 2000 cycles was performed. This was followed by measurement of tendon strain, repair site displacement, load to failure, and tendon stiffness. The knotted suture bridge repair had a significantly higher load to failure compared with the knotless suture bridge (mean ± SD, 317.8 ± 93.6 N vs 196.1 ± 12.1 N, respectively; P = .001). All constructs failed at the tendon-suture interface. Tendon strain after cyclic testing was significantly greater in the knotless (1.20 ± 1.05) compared with the knotted (0.39 ± 0.4) suture repair groups (P = .011). There was no significant difference in footprint size between the knotted (230.3 ± 63.3 mm(2)) and knotless (248.5 ± 48.8 mm(2)) groups (P = .40). There was also no significant difference in stiffness (knotted = 76.4 ± 8.0 N/mm; knotless = 69.6 ± 10.9 N/mm; P = .17) and repair site displacement after cyclic testing (knotted = 2.8 ± 1.2 mm; knotless = 3.6 ± 1.1 mm; P = .17). During suture bridge repair of the Achilles tendon after detachment, knots at the proximal suture anchors significantly improve the biomechanical strength of the repair. This study demonstrated that the knotless suture bridge repair had a significantly lower load to failure than the knotted suture bridge. Surgeons should be aware of these biomechanical differences, as they influence the postoperative rehabilitation protocol and may lead to higher surgical complication rates. © 2014 The Author(s).

  14. Tendon exhibits complex poroelastic behavior at the nanoscale as revealed by high-frequency AFM-based rheology.

    PubMed

    Connizzo, Brianne K; Grodzinsky, Alan J

    2017-03-21

    Tendons transmit load from muscle to bone by utilizing their unique static and viscoelastic tensile properties. These properties are highly dependent on the composition and structure of the tissue matrix, including the collagen I hierarchy, proteoglycans, and water. While the role of matrix constituents in the tensile response has been studied, their role in compression, particularly in matrix pressurization via regulation of fluid flow, is not well understood. Injured or diseased tendons and tendon regions that naturally experience compression are known to have alterations in glycosaminoglycan content, which could modulate fluid flow and ultimately mechanical function. While recent theoretical studies have predicted tendon mechanics using poroelastic theory, no experimental data have directly demonstrated such behavior. In this study, we use high-bandwidth AFM-based rheology to determine the dynamic response of tendons to compressive loading at the nanoscale and to determine the presence of poroelastic behavior. Tendons are found to have significant characteristic dynamic relaxation behavior occurring at both low and high frequencies. Classic poroelastic behavior is observed, although we hypothesize that the full dynamic response is caused by a combination of flow-dependent poroelasticity as well as flow-independent viscoelasticity. Tendons also demonstrate regional dependence in their dynamic response, particularly near the junction of tendon and bone, suggesting that the structural and compositional heterogeneity in tendon may be responsible for regional poroelastic behavior. Overall, these experiments provide the foundation for understanding fluid-flow-dependent poroelastic mechanics of tendon, and the methodology is valuable for assessing changes in tendon matrix compressive behavior at the nanoscale. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. The Location-Specific Role of Proteoglycans in the Flexor Carpi Ulnaris Tendon

    PubMed Central

    Buckley, Mark R.; Huffman, George R.; Iozzo, Renato V.; Birk, David E.; Soslowsky, Louis J.

    2015-01-01

    Tendons like the flexor carpi ulnaris (FCU) that contain region-specific distributions of proteoglycans (PGs) as a result of the heterogeneous, multi-axial loads they are subjected to in vivo provide valuable models for understanding structure-function relationships in connective tissues. However, the contributions of specific PGs to FCU tendon mechanical properties are unknown. Therefore, the objective of this study was to determine how the location-dependent, viscoelastic mechanical properties of the FCU tendon are impacted individually by PG-associated glycosaminoglycans (GAGs) and by two small leucine-rich proteoglycans (SLRPs), biglycan and decorin. Full length FCU tendons from biglycan- and decorin-null mice were compared to wild type mice to evaluate the effects of specific SLRPs, while chondroitinase ABC digestion of isolated specimens removed from the tendon midsubstance was used to determine how chontroitin/dermatan sulfate (CS/DS) GAGs impact mechanics in mature FCU tendons. A novel combined genetic knockout/ digestion technique also was employed to compare SLRP-null and wild-type tendons in the absence of CS/DS GAGs that may impact properties in the mature state. In all genotypes, mechanical properties in the FCU tendon midsubstance were not affected by GAG digestion. Full-length tendons exhibited complex, multi-axial deformation under tension that may be associated with their in vivo loading environment. Mechanical properties were adversely affected by the absence of biglycan, and a decreased modulus localized in the center of the tendon was measured. These results help elucidate the role that local alterations in proteoglycan levels may play in processes that adversely impact tendon functionality including injury and pathology. PMID:23941206

  16. Flexor Tendon Repair With Looped Suture: 1 Versus 2 Knots.

    PubMed

    Gil, Joseph A; Skjong, Christian; Katarincic, Julia A; Got, Christopher

    2016-03-01

    To assess the strength of flexor tendon repair with looped suture. We hypothesized that, after passing the intact looped suture in the desired repair configuration, splitting the loop and tying 2 independent knots would increase the strength of flexor tendon repair. Thirty-two flexor tendons were harvested and were sharply transected in zone II. The tendons were repaired with a 4-strand core suture repair using 3-0 looped nonabsorbable nylon suture. The harvested tendons were randomly assigned and repaired with either a 1- or a 2-knot construct. The repaired flexor tendons were fixed in a servohydraulic material testing system and were loaded to failure either with uniaxial tension or cyclically. The average force at failure was 43 N for the 1-knot repair and 28 N for the 2-knot repair. The mode of failure of 15 of the flexor tendon repairs that were cyclically loaded to failure was suture pull-out. The average number of cycles and force in cyclic testing that caused failure of flexor tendon repairs was 134 cycles and 31 N for tendons repaired with looped 3-0 suture tied with 1 knot and 94 cycles and 33 N for tendons repaired with looped 3-0 suture tied with 2 knots. Our hypothesis was disproved by the results of this study. This study suggests that, when using looped suture, tying 2 independent knots instead of tying a single knot does not increase the strength of the flexor tendon repair. Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  17. Effects of fast walking on tibiofemoral bone water content in middle-aged adults.

    PubMed

    Ho, Kai-Yu; Standerfer, Alexa; Ngo, Suzenna; Daun, Karen; Lee, Szu-Ping

    2016-08-01

    Although it is believed that genu varum increases loading on the medial knee during locomotion, the acute effect of increased loading on bone stress has not been determined. This study aimed to examine the effects of locomotion and lower extremity alignment on bone water content in middle-aged adults without knee osteoarthritis. Five males and 5 females participated. Lower extremity alignment was defined as the angle between the midpoint of the anterior mid-thigh and the midpoint of the patellar tendon using the center of the patella as the fulcrum. A chemical-shift-encoded water-fat magnetic resonance imaging protocol was used to assess bone water content before and after a 30-minute fast walking session. Bone stress response was determined by quantifying water content within the weight-bearing regions of the medial and lateral compartments of the tibiofemoral joint. Paired t-tests were used to compare bone water content before and after fast walking. Pearson correlation coefficients were used to determine the associations between lower extremity alignment and changes in water content post-walking. The paired t-tests revealed no changes in water content after fast walking within medial and lateral femur/tibia (P>0.05). Pearson correlation analyses revealed a significant moderate correlation between increased bone water content of the medial femur and increased varus alignment (R=0.688, P=0.028). Although there was no significant change in bone water content following locomotion, knee varus was associated with signs of bone stress in the medial femur. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. A new directly moulded patellar-tendon-bearing socket.

    PubMed

    Boot, D A; Young, N J

    1985-08-01

    Silicone rubbers and casting tapes individually have previously been used in the manufacture of sockets (Swanson, 1972; Sweitzer, 1973; Ruder, 1977; Graves, 1980; Aqualite, 1982). The authors believe that the present combination of these materials to manufacture a directly moulded socket with a complete silicone rubber lining of variable thickness has not previously been described. The new socket, after addition of the modular components, allows fitting of an aligned below-knee prosthesis within three hours. The socket (Fig. 1.) is made directly on the below-knee stump, can be completed with experience in an hour and does not require the use of specialized equipment. The socket consists of an outer supportive Scotchflex layer inside which is a lining of soft smooth biocompatible silicone rubber of deliberately variable thickness to allow pressure tolerant areas to accept more load and pressure sensitive areas to accept less load (Fig.2). The thicker areas of silicone are produced by applying carefully cut Plastazote pads to the pressure sensitive areas. The thickness and extent of the pads is individually assessed according to the estimated sensitivity of the particular area (Fig. 3). The Scotchflex socket is then manufactured directly on the below-knee stump with these pads applied. The pads are then removed prior to insertion of a semi-liquid silicone rubber. Thus, when the socket with the liquid silicone rubber is re-applied to the stump, the space produced by the pads is filled by the rubber which then sets at room temperature. In this way a layer of variable thickness is produced.(ABSTRACT TRUNCATED AT 250 WORDS)

  19. The role of three-dimensional pure bovine gelatin scaffolds in tendon healing, modeling, and remodeling: an in vivo investigation with potential clinical value.

    PubMed

    Oryan, Ahmad; Sharifi, Pardis; Moshiri, Ali; Silver, Ian A

    2017-09-01

    Large tendon defects involving extensive tissue loss present complex clinical problems. Surgical reconstruction of such injuries is normally performed by transplanting autogenous and allogenous soft tissues that are expected to remodel to mimic a normal tendon. However, the use of grafts has always been associated with significant limitations. Tissue engineering employing artificial scaffolds may provide acceptable alternatives. Gelatin is a hydrolyzed form of collagen that is bioactive, biodegradable, and biocompatible. The present study has investigated the suitability of gelatin scaffold for promoting healing of a large tendon-defect model in rabbits. An experimental model of a large tendon defect was produced by partial excision of the Achilles tendon of the left hind leg in adult rabbits. To standardize and stabilize the length of the tendon defect a modified Kessler core suture was anchored in the sectioned tendon ends. The defects were either left untreated or filled with three-dimensional gelatin scaffold. Before euthanasia 60 days after injury, the progress of healing was evaluated clinically. Samples of healing tendon were harvested at autopsy and evaluated by gross, histopathologic, scanning, and transmission electron microscopy, and by biomechanical testing. The treated animals showed superior weight-bearing and physical activity compared with those untreated, while frequency of peritendinous adhesions around the healing site was reduced. The gelatin scaffold itself was totally degraded and replaced by neo-tendon that morphologically had significantly greater numbers, diameters, density, and maturation of collagen fibrils, fibers, and fiber bundles than untreated tendon scar tissue. It also had mechanically higher ultimate load, yield load, stiffness, maximum stress and elastic modulus, when compared to the untreated tendons. Gelatin scaffold may be a valuable option in surgical reconstruction of large tendon defects.

  20. New regimen for eccentric calf-muscle training in patients with chronic insertional Achilles tendinopathy: results of a pilot study.

    PubMed

    Jonsson, P; Alfredson, H; Sunding, K; Fahlström, M; Cook, J

    2008-09-01

    Chronic painful insertional Achilles tendinopathy is seen in both physically active and non-active individuals. Painful eccentric training, where the patients load the Achilles tendon into full dorsiflexion, has shown good results in patients with mid-portion Achilles tendinosis. However, only 32% of patients with insertional Achilles tendinopathy had good clinical results with that type of eccentric training regimen. To investigate whether a new model of painful eccentric training had an effect on chronic painful insertional Achilles tendinopathy. 27 patients (12 men, 15 women, mean age 53 years) with a total of 34 painful Achilles tendons with a long duration of pain (mean 26 months), diagnosed as insertional Achilles tendinopathy, were included. The patients performed a new model of painful eccentric training regimen without loading into dorsiflexion. This was done as 3x15 reps, twice a day, 7 days/week, for 12 weeks. Pain during Achilles-tendon-loading activity (VAS) and patient's satisfaction (back to previous activity) were evaluated. At follow-up (mean 4 months) 18 patients (67%, 23/34 tendons) were satisfied and back to their previous tendon-loading activity. Their mean VAS had decreased from 69.9 (SD 18.9) to 21 (SD 20.6) (p<0.001). Nine patients (11 tendons) were not satisfied with the treatment, although their VAS was significantly reduced from 77.5 (8.6) to 58.1 (14.8) (p<0.01). In this short-term pilot study this new model of painful eccentric calf-muscle training showed promising clinical results in 67% of the patients.

  1. Effects of Patellofemoral Taping on Patellofemoral Joint Alignment and Contact Area During Weight Bearing.

    PubMed

    Ho, Kai-Yu; Epstein, Ryan; Garcia, Ron; Riley, Nicole; Lee, Szu-Ping

    2017-02-01

    Study Design Controlled laboratory study. Background Although it has been theorized that patellofemoral joint (PFJ) taping can correct patellar malalignment, the effects of PFJ taping techniques on patellar alignment and contact area have not yet been studied during weight bearing. Objective To examine the effects of 2 taping approaches (Kinesio and McConnell) on PFJ alignment and contact area. Methods Fourteen female subjects with patellofemoral pain and PFJ malalignment participated. Each subject underwent a pretaping magnetic resonance imaging (MRI) scan session and 2 MRI scan sessions after the application of the 2 taping techniques, which aimed to correct lateral patellar displacement. Subjects were asked to report their pain level prior to each scan session. During MRI assessment, subjects were loaded with 25% of body weight on their involved/more symptomatic leg at 0°, 20°, and 40° of knee flexion. The outcome measures included patellar lateral displacement (bisect-offset [BSO] index), mediolateral patellar tilt angle, patellar height (Insall-Salvati ratio), contact area, and pain. Patellofemoral joint alignment and contact area were compared among the 3 conditions (no tape, Kinesio, and McConnell) at 3 knee angles using a 2-factor, repeated-measures analysis of variance. Pain was compared among the 3 conditions using the Friedman test and post hoc Wilcoxon signed-rank tests. Results Our data did not reveal any significant effects of either McConnell or Kinesio taping on the BSO index, patellar tilt angle, Insall-Salvati ratio, or contact area across the 3 knee angles, whereas knee angle had a significant effect on the BSO index and contact area. A reduction in pain was observed after the application of the Kinesio taping technique. Conclusion In a weight-bearing condition, this preliminary study did not support the use of PFJ taping as a medial correction technique to alter the PFJ contact area or alignment of the patella. J Orthop Sports Phys Ther 2017;47(2):115-123. doi:10.2519/jospt.2017.6936.

  2. Bone-Patellar Tendon-Bone Versus Soft-Tissue Allograft for Anterior Cruciate Ligament Reconstruction: A Systematic Review.

    PubMed

    Joyce, Christopher D; Randall, Kyle L; Mariscalco, Michael W; Magnussen, Robert A; Flanigan, David C

    2016-02-01

    To describe the outcomes of bone-patellar tendon-bone (BPTB) and soft-tissue allografts in anterior cruciate ligament (ACL) reconstruction with respect to graft failure risk, physical examination findings, instrumented laxity, and patient-reported outcomes. A search of the PubMed, Scopus, CINAHL (Cumulative Index to Nursing and Allied Health Literature) Complete, Cochrane Collaboration, and SPORTDiscus databases was performed. English-language studies with outcome data on primary ACL reconstruction with nonirradiated BPTB and soft-tissue allografts were identified. Outcome data included failure risk, physical examination findings, instrumented laxity measurements, and patient-reported outcome scores. Seventeen studies met the inclusion criteria. Of these studies, 11 reported on BPTB allografts exclusively, 5 reported on soft-tissue allografts exclusively, and 1 compared both types. The comparative study showed no difference in failure risk, Lachman grade, pivot-shift grade, instrumented laxity, or overall International Knee Documentation Committee score between the 2 allograft types. Data from all studies yielded a failure risk of 10.3% (95% confidence interval [CI], 4.5% to 18.1%) in the soft-tissue group and 15.2% (95% CI, 11.3% to 19.6%) in the BPTB group. The risk of a Lachman grade greater than 5 mm was 6.4% (95% CI, 1.7% to 13.7%) in the soft-tissue group and 8.6% (95% CI, 6.3% to 11.2%) in the BPTB group. The risk of a grade 2 or 3 pivot shift was 1.4% (95% CI, 0.3% to 3.3%) in the soft-tissue group and 4.1% (95% CI, 1.9% to 7.2%) in the BPTB group. One comparative study showed no difference in results after ACL reconstruction with nonirradiated BPTB and soft-tissue allografts. Inclusion of case series in the analysis showed qualitatively similar outcomes with the 2 graft types. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  3. Immediate post-operative pain in anterior cruciate ligament reconstruction surgery with bone patellar tendon bone graft versus hamstring graft.

    PubMed

    Gupta, Ravi; Kapoor, Dheeraj; Kapoor, Love; Malhotra, Anubhav; Masih, Gladson David; Kapoor, Anil; Joshi, Shweta

    2016-06-08

    Pain in the immediate post-operative period after anterior cruciate ligament (ACL) surgery, apart from an unpleasant experience for the patient, can act as a barrier for static quadriceps contractions and optimum execution of the initial rehabilitation protocol resulting in slow recovery and a later return to full function for a sportsperson. There is no report in the literature comparing pain in the immediate post-operative period after using the two most widely used autografts, bone patellar tendon bone (BPTB) graft and hamstring graft. The present study compared the visual analogue scale (VAS) pain score in the immediate post-operative period after arthroscopic ACL reconstruction with the BPTB and hamstring autografts. Both groups consisted of 50 patients each. The mean age of the BPTB and hamstring cohorts was 26.9 ± 7.3 years (age range 18-59 years) and 26.7 ± 9.0 years (age range 17-52 years), respectively. Unpaired t test was applied to compare pain scores between the BPTB and hamstring cohorts. In the present study, patients in the BPTB cohort showed higher mean pain scores across all the post-operative time intervals except at 6 h. However, the difference in the mean VAS pain score at post-operative 6, 12,18, 24, 36 and 48 h in the two groups was statistically not significant (p value of 1, 0.665, 0.798, 0.377, 0.651 and 0.215 at 6, 12, 18, 24, 36 and 48 h, respectively). Our study concludes that the arthroscopic ACL reconstruction with BPTB autograft and hamstring autograft is associated with similar pain in the immediate post-operative period. As a result, aggressive physiotherapy regime is not affected by the type of graft being used for ACL reconstruction, as the pain scores in the immediate post-operative period are similar for both techniques. Clinical Trials Registry-India, CTRI/2016/01/006502.

  4. Long-term absorption of poly-L-lactic Acid interference screws.

    PubMed

    Barber, F Alan; Dockery, W Dee

    2006-08-01

    To evaluate the long term in vivo degradation of poly-L-lactic acid (PLLA) interference screws with computed tomography (CT) and radiography as used in patellar tendon autograft anterior cruciate ligament (ACL) reconstruction. A total of 20 patients who had undergone patellar tendon autograft ACL reconstruction fixed with PLLA screws at least 7 years earlier were evaluated by physical examination, radiography, and CT to determine whether PLLA screw reabsorption and bone ingrowth had occurred. This study was granted Institutional Review Board approval. Lysholm, Tegner, Cincinnati, and International Knee Documentation Committee (IKDC) scores were obtained. CT data were measured in Hounsfield units. In all, 15 men and 5 women were evaluated 104 months after surgery (range, 89 to 124 months). CT and radiography demonstrated that the bone plug had fused to the tunnel wall, and that no intact interference screw was left. A parallel, threaded, and corticated screw tract was visible adjacent to the bone plug. No bone ingrowth had occurred at the screw site, although, occasionally, minimal calcification was seen. This was never as dense as cancellous bone, and no trabeculae were ever present. No positive pivot-shift test results were obtained. Lysholm, Tegner, and Cincinnati scores were 83, 5.6, and 75, respectively, at follow-up. Average KT difference was 0.7 mm. PLLA interference screws completely degraded, and the resulting area demonstrated a low Hounsfield count, consistent with soft tissue 7 years after insertion. No significant bone ingrowth occurred at the screw site. Femoral and tibial ACL tunnels were absent of anything but fibrous tissue and usually had a sclerotic cortical lining. PLLA biodegradable ACL screws eventually disappear completely. PLLA material is not replaced by bone. ACL graft tunnels are filled with nonossified material. This study provides a baseline for comparison with other biodegradable interference screws that may encourage bone ingrowth as they degrade. Level IV (no or historical control).

  5. Double-layer versus single-layer bone-patellar tendon-bone anterior cruciate ligament reconstruction: a prospective randomized study with 3-year follow-up.

    PubMed

    Mei, Xiaoliang; Zhang, Zhenxiang; Yang, Jingwen

    2016-12-01

    To evaluate the clinical results of a randomized controlled trial of single-layer versus double-layer bone-patellar tendon-bone (BPTB) anterior cruciate ligament (ACL) reconstruction. Fifty-eight subjects who underwent primary ACL reconstruction with a BPTB allograft were prospectively randomized into two groups: single-layer reconstruction (n = 31) and double-layer reconstruction (n = 27). The following evaluation methods were used: clinical examination, KT-1000 arthrometer measurement, muscle strength, Tegner activity score, Lysholm score, subjective rating scale regarding patient satisfaction and sports performance level, graft retear, contralateral ACL tear, and additional meniscus surgery. Forty-eight subjects (24 in single-layer group and 24 in double-layer group) who were followed up for 3 years were evaluated. Preoperatively, there were no differences between the groups. At 3-year follow-up, the Lachman and pivot-shift test results were better in the double-layer group (P = 0.019 and P < 0.0001, respectively). KT measurements were better in the double-layer group (mean 2.9 versus 1.5 mm; P = 0.0025). The Tegner score was also better in the double-layer group (P = 0.024). There were no significant differences in range of motion, muscle strength, Lysholm score, subjective rating scale, graft retear, and secondary meniscal tear. In ACL reconstruction, double-layer BPTB reconstruction was significantly better than single-layer reconstruction regarding anterior and rotational stability at 3-year follow-up. The results of KT measurements and the Lachman and pivot-shift tests were significantly better in the double-layer group, whereas there was no difference in the anterior drawer test results. The Tegner score was also better in the double-layer group; however, there were no differences in the other subjective findings.

  6. Effects of initial graft tension on femoral tunnel widening after anatomic anterior cruciate ligament reconstruction using a bone-patellar tendon-bone graft.

    PubMed

    Taketomi, Shuji; Inui, Hiroshi; Tahara, Keitaro; Shirakawa, Nobuyuki; Tanaka, Sakae; Nakagawa, Takumi

    2017-09-01

    The effects of initial graft tension upon tunnel widening (TW) following anatomic anterior cruciate ligament (ACL) reconstruction have not been elucidated. The purpose of this study was to retrospectively investigate the effect of two different graft-tensioning protocols upon femoral TW following anatomic ACL reconstruction using a bone-patellar tendon-bone (BPTB) graft and a three-dimensional (3D) computed tomography (CT) model. Forty-three patients who underwent isolated ACL reconstruction using BPTB grafts were included in this study. In 18 out of the 43 patients, the graft was fixed at full knee extension with manual maximum pull (Group H). These patients were compared with 25 patients in whom the BPTB graft was fixed at full knee extension with 80-N pull (Group L). Tunnel aperture area was measured using 3D CT 1 week and 1 year postoperatively, thus enabling us to calculate the percentage change in the area of femoral tunnel aperture. Clinical assessment was performed 1 year postoperatively, corresponding to the time period of CT assessment, and involved the evaluation of Lysholm score, anterior knee stability using a KneeLax3 arthrometer, and the pivot-shift test. When measured at 1 year postoperatively, the mean area of the femoral tunnel aperture had increased by 78.6 ± 36.8% in Group H when compared with at 1 week postoperatively, whereas that of Group L had increased by 27.7 ± 32.3%. Furthermore, TW (%) in Group H was significantly greater than that of Group L (P < 0.001). No significant differences were detected between the two groups with regard to any of the clinical outcomes evaluated. High levels of initial graft tension resulted in greater TW of the femoral tunnel aperture following anatomical ACL reconstruction using BPTB grafts. However, such levels of graft tension did not affect clinical outcome.

  7. Is there still a place for Achilles tendon lengthening?

    PubMed

    Tagoe, Mark T; Reeves, Neil D; Bowling, Frank L

    2016-01-01

    Patients with diabetes and ankle equinus are at particularly high risk for forefoot ulceration because of the development of high forefoot pressures. Stiffness in the triceps surae muscles and tendons are thought to be largely responsible for equinus in patients with diabetes and underpins the surgical rationale for Achilles tendon lengthening (ATL) procedures to alleviate this deformity and reduce ulcer risk. The established/traditional surgical approach is the triple hemisection along the length of the Achilles tendon. Although the percutaneous approach has been successful in achieving increases in ankle dorsiflexion >30°, the tendon rupture risk has led to some surgeons looking at alternative approaches. The gastrocnemius aponeurosis may be considered as an alternative because of the Achilles tendon's poor blood supply. ATL procedures are a balance between achieving adequate tendon lengthening and minimizing tendon rupture risk during or after surgery. After ATL surgery, the first 7 days should involve reduced loading and protected range of motion to avoid rupture, after which gradual reintroduction to loading should be encouraged to increase tendon strength. In summary, there is a moderate level of evidence to support surgical intervention for ankle joint equinus in patients with diabetes and forefoot ulceration that is non-responsive to other conservative treatments. Areas of caution for ATL procedures include the risk for overcorrection, tendon rupture and the tendon's poor blood supply. Further prospective randomized control trials are required to confirm the benefits of ATL procedures over conservative care and the most optimal anatomical sites for surgical intervention. Copyright © 2016 John Wiley & Sons, Ltd.

  8. The Influence of Task Complexity on Knee Joint Kinetics Following ACL Reconstruction

    PubMed Central

    Schroeder, Megan J.; Krishnan, Chandramouli; Dhaher, Yasin Y.

    2015-01-01

    Background Previous research indicates that subjects with anterior cruciate ligament reconstruction exhibit abnormal knee joint movement patterns during functional activities like walking. While the sagittal plane mechanics have been studied extensively, less is known about the secondary planes, specifically with regard to more demanding tasks. This study explored the influence of task complexity on functional joint mechanics in the context of graft-specific surgeries. Methods In 25 participants (10 hamstring tendon graft, 6 patellar tendon graft, 9 matched controls), three-dimensional joint torques were calculated using a standard inverse dynamics approach during level walking and stair descent. The stair descent task was separated into two functionally different sub-tasks—step-to-floor and step-to-step. The differences in external knee moment profiles were compared between groups; paired differences between the reconstructed and non-reconstructed knees were also assessed. Findings The reconstructed knees, irrespective of graft type, typically exhibited significantly lower peak knee flexion moments compared to control knees during stair descent, with the differences more pronounced in the step-to-step task. Frontal plane adduction torque deficits were graft-specific and limited to the hamstring tendon knees during the step-to-step task. Internal rotation torque deficits were also primarily limited to the hamstring tendon graft group during stair descent. Collectively, these results suggest that task complexity was a primary driver of differences in joint mechanics between anterior cruciate ligament reconstructed individuals and controls, and such differences were more pronounced in individuals with hamstring tendon grafts. Interpretation The mechanical environment experienced in the cartilage during repetitive, cyclical tasks such as walking and other activities of daily living has been argued to contribute to the development of degenerative changes to the joint and ultimately osteoarthritis. Given the task-specific and graft-specific differences in joint mechanics detected in this study, care should be taken during the rehabilitation process to mitigate these changes. PMID:26101055

  9. Genetic Response of Rat Supraspinatus Tendon and Muscle to Exercise

    PubMed Central

    Rooney, Sarah Ilkhanipour; Tobias, John W.; Bhatt, Pankti R.; Kuntz, Andrew F.; Soslowsky, Louis J.

    2015-01-01

    Inflammation is a complex, biologic event that aims to protect and repair tissue. Previous studies suggest that inflammation is critical to induce a healing response following acute injury; however, whether similar inflammatory responses occur as a result of beneficial, non-injurious loading is unknown. The objective of this study was to screen for alterations in a subset of inflammatory and extracellular matrix genes to identify the responses of rat supraspinatus tendon and muscle to a known, non-injurious loading condition. We sought to define how a subset of genes representative of specific inflammation and matrix turnover pathways is altered in supraspinatus tendon and muscle 1) acutely following a single loading bout and 2) chronically following repeated loading bouts. In this study, Sprague-Dawley rats in the acute group ran a single bout of non-injurious exercise on a flat treadmill (10 m/min, 1 hour) and were sacrificed 12 or 24 hours after. Rats in the chronic group ran 5 days/wk for 1 or 8 weeks. A control group maintained normal cage activity. Supraspinatus muscle and tendon were harvested for RNA extractions, and a custom Panomics QuantiGene 2.0 multiplex assay was used to detect 48 target and 3 housekeeping genes. Muscle/tendon and acute/chronic groups had distinct gene expression. Components of the arachidonic acid cascade and matrix metalloproteinases and their inhibitors were altered with acute and chronic exercise. Collagen expression increased. Using a previously validated model of non-injurious exercise, we have shown that supraspinatus tendon and muscle respond to acute and chronic exercise by regulating inflammatory- and matrix turnover-related genes, suggesting that these pathways are involved in the beneficial adaptations to exercise. PMID:26447778

  10. Prosthetic joint infection caused by Trueperella bernardiae.

    PubMed

    Gilarranz, Raul; Chamizo, Francisco; Horcajada, Iballa; Bordes-Benítez, Ana

    2016-09-01

    Trueperella bernardiae is a Gram-positive coryneform bacilli which role as human pathogen is unknown because it has been usually considered a contaminant. Furthermore its identification by biochemical test was difficult. We describe a prosthetic joint infection in a women who years ago underwent a total knee replacement with superinfection and necrosis of the patellar tendon as major complications. In the sample of synovial fluid collected grew a gram-positive bacilli which was identified by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) as T. bernardiae. The patient was treated with ciprofloxacin and currently preserves the prosthesis without signs of infection. Copyright © 2016 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  11. Fascicles from energy-storing tendons show an age-specific response to cyclic fatigue loading

    PubMed Central

    Thorpe, Chavaunne T.; Riley, Graham P.; Birch, Helen L.; Clegg, Peter D.; Screen, Hazel R. C.

    2014-01-01

    Some tendons, such as the human Achilles and equine superficial digital flexor tendon (SDFT), act as energy stores, stretching and recoiling to increase efficiency during locomotion. Our previous observations of rotation in response to applied strain in SDFT fascicles suggest a helical structure, which may provide energy-storing tendons with a greater ability to extend and recoil efficiently. Despite this specialization, energy-storing tendons are prone to age-related tendinopathy. The aim of this study was to assess the effect of cyclic fatigue loading (FL) on the microstructural strain response of SDFT fascicles from young and old horses. The data demonstrate two independent age-related mechanisms of fatigue failure; in young horses, FL caused low levels of matrix damage and decreased rotation. This suggests that loading causes alterations to the helix substructure, which may reduce their ability to recoil and recover. By contrast, fascicles from old horses, in which the helix is already compromised, showed greater evidence of matrix damage and suffer increased fibre sliding after FL, which may partially explain the age-related increase in tendinopathy. Elucidation of helix structure and the precise alterations occurring owing to both ageing and FL will help to develop appropriate preventative and repair strategies for tendinopathy. PMID:24402919

  12. The development and morphogenesis of the tendon-to-bone insertion What development can teach us about healing

    PubMed Central

    Thomopoulos, Stavros; Genin, Guy M.; Galatz, Leesa M.

    2013-01-01

    The attachment of dissimilar materials is a major challenge because of the high levels of stress that develop at such interfaces. An effective solution to this problem develops at the attachment of tendon (a compliant “soft tissue”) to bone (a stiff “hard tissue”). This tissue, the “enthesis”, transitions from tendon to bone through gradations in structure, composition, and mechanical properties. These gradations are not regenerated during tendon-to-bone healing, leading to a high incidence of failure after surgical repair. Understanding the development of the enthesis may allow scientists to develop treatments that regenerate the natural tendon-to-bone insertion. Recent work has demonstrated that both biologic and mechanical factors drive the development and morphogenesis of the enthesis. A cascade of biologic signals similar to those seen in the growth plate promotes mineralization of cartilage on the bony end of the enthesis and the formation of fibrocartilage on the tendon end of the enthesis. Mechanical loading is also necessary for the development of the enthesis. Removal of muscle load impairs the formation of bone, fibrocartilage, and tendon at the developing enthesis. This paper reviews recent work on the development of the enthesis, with an emphasis on the roles of biologic and mechanical factors. PMID:20190378

  13. Delayed Exercise Promotes Remodeling in Sub-Rupture Fatigue Damaged Tendons

    PubMed Central

    Bell, R.; Boniello, M.R.; Gendron, N.R.; Flatow, E.L.; Andarawis-Puri, N.

    2015-01-01

    Tendinopathy is a common musculoskeletal injury whose treatment is limited by ineffective therapeutic interventions. Previously we have shown that tendons ineffectively repair early sub-rupture fatigue damage. In contrast, physiological exercise has been shown to promote remodeling of healthy tendons but its utility as a therapeutic to promote repair of fatigue damaged tendons remains unknown. Therefore, the objective of this study was to assess the utility of exercise initiated 1 and 14 days after onset of fatigue damage to promote structural repair in fatigue damaged tendons. We hypothesized that exercise initiated 14 days after fatigue loading would promote remodeling as indicated by a decrease in area of collagen matrix damage, increased procollagen I and decorin, while decreasing proteins indicative of tendinopathy. Rats engaged in 6-week exercise for 30 min/day or 60 min/day starting 1 or 14 days after fatigue loading. Initiating exercise 1-day after onset of fatigue injury led to exacerbation of matrix damage, particularly at the tendon insertion. Initiating exercise 14 days after onset of fatigue injury led to remodeling of damaged regions in the midsubstance and collagen synthesis at the insertion. Physiological exercise applied after the initial biological response to injury has dampened can potentially promote remodeling of damaged tendons. PMID:25732052

  14. Biomechanical evaluation of a novel suturing scheme for grafting load-bearing collagen scaffolds for rotator cuff repair

    PubMed Central

    Islam, Anowarul; Bohl, Michael S.; Tsai, Andrew G; Younesi, Mousa; Gillespie, Robert; Akkus, Ozan

    2015-01-01

    Background Currently, there are no well-established suture protocols to attach fully load-bearing scaffolds which span tendon defects between bone and muscle for repair of critical sized tendon tears. Methods to attach load-bearing tissue repair scaffolds could enable functional repair of tendon injuries. Methods Sixteen rabbit shoulders were dissected (New Zealand white rabbits, 1 yr. old, female) to isolate the humeral-infraspinatus muscle complex. A unique suture technique was developed to allow for a 5 mm segmental defect in infraspinatus tendon to be replaced with a mechanically strong bioscaffold woven from pure collagen threads. The suturing pattern resulted in a fully load-bearing scaffold. The tensile stiffness and strength of scaffold repair was compared with intact infraspinatus and regular direct repair. Findings The failure load and displacement at failure of the scaffold repair group were 59.9 N (Standard Deviation, SD = 10.7) and 10.3 mm (SD = 2.9), respectively and matched those obtained by direct repair group which were 57.5 N (SD = 15.3) and 8.6 mm (SD = 1.5), (p > 0.05). Failure load, displacement at failure and stiffness of both of the repair groups were half of the intact infraspinatus shoulder group. Interpretation With the developed suture technique, scaffolds repair showed similar failure load, displacement at failure and stiffness to the direct repair. This novel suturing pattern and the mechanical robustness of the scaffold at time zero indicates that the proposed model is mechanically viable for future in vivo studies which has a higher potential to translate into clinical uses. PMID:26009492

  15. Biomechanical evaluation of a single-row versus double-row repair for complete subscapularis tears.

    PubMed

    Wellmann, Mathias; Wiebringhaus, Philipp; Lodde, Ina; Waizy, Hazibullah; Becher, Christoph; Raschke, Michael J; Petersen, Wolf

    2009-12-01

    The purpose of the study was to compare a single-row repair and a double-row repair technique for the specific characteristics of a complete subscapularis lesion. Ten pairs of human cadaveric shoulder human shoulder specimens were tested for stiffness and ultimate tensile strength of the intact tendons in a load to failure protocol. After a complete subscapularis tear was provoked, the specimens were assigned to two treatment groups: single-row repair (1) and a double-row repair using a "suture bridge" technique (2). After repair cyclic loading a subsequent load to failure protocol was performed to determine the ultimate tensile load, the stiffness and the elongation behaviour of the reconstructions. The intact subscapularis tendons had a mean stiffness of 115 N/mm and a mean ultimate load of 720 N. The predominant failure mode of the intact tendons was a tear at the humeral insertion site (65%). The double-row technique restored 48% of the ultimate load of the intact tendons (332 N), while the single-row technique revealed a significantly lower ultimate load of 244 N (P = 0.001). In terms of the stiffness, the double-row technique showed a mean stiffness of 81 N/mm which is significantly higher compared to the stiffness of the single-row repairs of 55 N/mm (P = 0.001). The double-row technique has been shown to be stronger and stiffer when compared to a conventional single-row repair. Therefore, this technique is recommended from a biomechanical point of view irrespectively if performed by an open or arthroscopic approach.

  16. Treatment of patella baja by a modified Z-plasty.

    PubMed

    Guido, Wierer; Christian, Hoser; Elmar, Herbst; Elisabeth, Abermann; Christian, Fink

    2016-09-01

    The purpose of this study was to evaluate the efficiency of a modified Z-plasty for patellar tendon lengthening for the treatment of patella baja. Rather than adapting only two tendon reins according to the conventional Z-plasty method, the modified Z-plasty provides four reins to enable multifold overlapping of the tendon tissue. Between 2010 and 2012, a modified Z-plasty procedure was performed in four patients suffering from patella baja. Physical examinations and standardized scoring instruments served as the evaluation measures. The median preoperative CD ratio of 0.53 (range 0.43-0.62) was corrected to 1.03 (range 1-1.06) after a median follow-up of 34 months (range 23-41 months). The median preoperative flexion of 108° (range 80-135°) improved to 143° (range 110-145°) compared with the flexion of 145° (range 140-145°) of the unaffected knee. No patients showed any signs of extension lag. The median Lysholm score improved from 49 (range 22-80) to 91 (range 67-95), and the Tegner activity level improved from 2 (range 0-6) to 6 (range 2-6). The median VAS status for pain decreased from an average of 8.5 (range 4-10) to 1 (range 0-2). No complications were observed. The modified Z-plasty procedure is a valuable technique for the treatment of patella baja, especially if allografts are not available. This procedure allowed for early mobilization and achieved excellent clinical results. IV.

  17. The effect of sterilization on mechanical properties of soft tissue allografts.

    PubMed

    Conrad, Bryan P; Rappé, Matthew; Horodyski, MaryBeth; Farmer, Kevin W; Indelicato, Peter A

    2013-09-01

    One major concern regarding soft tissue allograft use in surgical procedures is the risk of disease transmission. Current techniques of tissue sterilization, such as irradiation have been shown to adversely affect the mechanical properties of soft tissues. Grafts processed using Biocleanse processing (a proprietary technique developed by Regeneration Technologies to sterilize human tissues) will have better biomechanical characteristics than tissues that have been irradiated. Fifteen pairs of cadaveric Achilles tendon allografts were obtained and separated into three groups of 10 each. Three treatment groups were: Biocleanse, Irradiated, and Control (untreated). Each specimen was tested to determine the biomechanical properties of the tissue. Specimens were cyclically preloaded and then loaded to failure in tension. During testing, load, displacement, and optical strain data were captured. Following testing, the cross sectional area of the tendons was determined. Tendons in the control group were found to have a higher extrinsic stiffness (slope of the load-deformation curve, p = .005), have a higher ultimate stress (force/cross sectional area, p = .006) and higher ultimate failure load (p = .003) than irradiated grafts. Biocleanse grafts were also found to be stiffer than irradiated grafts (p = .014) yet were not found to be statistically different from either irradiated or non-irradiated grafts in terms of load to failure. Biocleanse processing seems to be a viable alternative to irradiation for Achilles tendon allografts sterilization in terms of their biomechanical properties.

  18. Mechanical Strength of the Side-to-Side Versus Pulvertaft Weave Tendon Repair

    PubMed Central

    Brown, Stephen H. M.; Hentzen, Eric R.; Kwan, Alan; Ward, Samuel R.; Fridén, Jan; Lieber, Richard L.

    2010-01-01

    Purpose The side-to-side (SS) tendon suture technique was designed to function as a repair that permits immediate post-operative activation and mobilization of a transferred muscle. This study was designed to test the strength and stiffness of the SS technique against a variation of the Pulvertaft (PT) repair technique. Methods Flexor digitorum superficialis (FDS) and flexor digitorum profundus (FDP) tendons were harvested from four fresh cadavers and used as a model system. Seven SS and six PT repairs were performed using the FDS as the donor and the FDP as the recipient tendon. For SS repairs, the FDS was woven through one incision in the FDP, and was joined with four cross-stitch running sutures down both sides, and one double-loop suture at each tendon free end; for PT repairs, FDS was woven through three incisions in FDP, joined with a double-loop suture at both ends of the overlap, and four evenly spaced mattress sutures between the ends. Tendon repairs were placed in a tensile testing machine, pre-conditioned and tested to failure. Results There were no statistically significant differences in cross-sectional area (p=0.99) or initial length (p=0.93) between SS and PT repairs. Therefore, all comparisons between methods were made using measures of loads and deformations, rather than stresses and strains.. All failures occurred in the repair region, rather than at the clamps. However, failure mechanisms were different between the two techniques—PT repairs failed by the suture knots either slipping or pulling through the tendon material, followed by the FDS tendon pulling through the FDP tendon; SS repairs failed by shearing of fibers within the FDS. Load at first failure (p < 0.01), ultimate load (p < 0.001), and repair stiffness (p < 0.05) were all significantly different between SS and PT techniques; in all cases the mean value for SS was higher than for PT. Discussion The SS repair, using a cross-stitch suture technique, was significantly stronger and stiffer compared to the PT repair using a mattress suture technique. This suggests that using SS repairs could enable patients to load the repair soon after surgery. Ultimately, this should reduce the risk of developing adhesions and result in improved functional outcome and fewer complications in the acute post-operative period. Future work will address the specific mechanisms (for example, suture-throw technique, tendon-weave technique) that underlie the improved strength and stiffness of the SS repair. PMID:20223604

  19. Lipids, adiposity and tendinopathy: is there a mechanistic link? Critical review

    PubMed Central

    Scott, Alex; Zwerver, Johannes; Grewal, Navi; de Sa, Agnetha; Alktebi, Thuraya; Granville, David J; Hart, David A

    2015-01-01

    Being overweight or obese is associated with an elevated risk of tendon pathology. However, for sportspeople the epidemiological data linking weight or adiposity on one hand, and risk of tendon pathology on the other, are less consistent. Indeed, the mechanistic links between diet, adiposity and tendon pathology remain largely unexamined. Recent studies have begun to examine the effects of dietary interventions on outcomes such as tendon biomechanics or pain. Oxidised low-density lipoprotein has been shown to (A) accumulate in the tendon tissues of mice that eat a fatty diet and (B) induce a pathological phenotype in human tendon cells. This paper addresses the current debate: is excessive body mass index (causing increased load and strain on tendon tissue) per se the underlying mechanism? Or do local or systemic influences of fat on tendons predispose to tendon pathology? This narrative review argues that excessive blood lipids may be an important avenue for clinical investigations. PMID:25488953

  20. Effects of barefoot and barefoot inspired footwear on knee and ankle loading during running.

    PubMed

    Sinclair, Jonathan

    2014-04-01

    Recreational runners frequently suffer from chronic pathologies. The knee and ankle have been highlighted as common injury sites. Barefoot and barefoot inspired footwear have been cited as treatment modalities for running injuries as opposed to more conventional running shoes. This investigation examined knee and ankle loading in barefoot and barefoot inspired footwear in relation to conventional running shoes. Thirty recreational male runners underwent 3D running analysis at 4.0m·s(-1). Joint moments, patellofemoral contact force and pressure and Achilles tendon forces were compared between footwear. At the knee the results show that barefoot and barefoot inspired footwear were associated with significant reductions in patellofemoral kinetic parameters. The ankle kinetics indicate that barefoot and barefoot inspired footwear were associated with significant increases in Achilles tendon force compared to conventional shoes. Barefoot and barefoot inspired footwear may serve to reduce the incidence of knee injuries in runners although corresponding increases in Achilles tendon loading may induce an injury risk at this tendon. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Lateral epicondylosis and calcific tendonitis in a golfer: a case report and literature review

    PubMed Central

    Yuill, Erik A.; Lum, Grant

    2011-01-01

    Objective To detail the progress of a young female amateur golfer who developed chronic left arm pain while playing golf 8 months prior to her first treatment visit. Clinical Features Findings included pain slightly distal to the lateral epicondyle of the elbow, decreased grip strength, and positive orthopedic testing. Diagnostic ultrasound showed thickening of the common extensor tendon origin indicating lateral epicondylosis. Radiographs revealed an oval shaped calcified density in the soft tissue adjacent to the lateral humeral epicondyle, indicating calcific tendonitis of the common extensor tendon origin. Intervention and Outcome Conventional care was aimed at decreasing the repetitive load on the common extensor tendon, specifically the extensor carpi radialis brevis. Soft tissue techniques, exercises and stretches, and an elbow brace helped to reduce repetitive strain. Outcome measures included subjective pain ratings, and follow up imaging 10 weeks after treatment began. Conclusion A young female amateur golfer with chronic arm pain diagnosed as lateral epicondylosis and calcific tendonitis was relieved of her pain after 7 treatments over 10 weeks of soft tissue and physical therapy focusing specifically on optimal healing and decreasing the repetitive load on the extensor carpi radialis brevis. PMID:22131570

  2. A Review on Biomechanics of Anterior Cruciate Ligament and Materials for Reconstruction

    PubMed Central

    Marieswaran, M.; Jain, Ishita; Garg, Bhavuk; Sharma, Vijay

    2018-01-01

    The anterior cruciate ligament is one of the six ligaments in the human knee joint that provides stability during articulations. It is relatively prone to acute and chronic injuries as compared to other ligaments. Repair and self-healing of an injured anterior cruciate ligament are time-consuming processes. For personnel resuming an active sports life, surgical repair or replacement is essential. Untreated anterior cruciate ligament tear results frequently in osteoarthritis. Therefore, understanding of the biomechanics of injury and properties of the native ligament is crucial. An abridged summary of the prominent literature with a focus on key topics on kinematics and kinetics of the knee joint and various loads acting on the anterior cruciate ligament as a function of flexion angle is presented here with an emphasis on the gaps. Briefly, we also review mechanical characterization composition and anatomy of the anterior cruciate ligament as well as graft materials used for replacement/reconstruction surgeries. The key conclusions of this review are as follows: (a) the highest shear forces on the anterior cruciate ligament occur during hyperextension/low flexion angles of the knee joint; (b) the characterization of the anterior cruciate ligament at variable strain rates is critical to model a viscoelastic behavior; however, studies on human anterior cruciate ligament on variable strain rates are yet to be reported; (c) a significant disparity on maximum stress/strain pattern of the anterior cruciate ligament was observed in the earlier works; (d) nearly all synthetic grafts have been recalled from the market; and (e) bridge-enhanced repair developed by Murray is a promising technique for anterior cruciate ligament reconstruction, currently in clinical trials. It is important to note that full extension of the knee is not feasible in the case of most animals and hence the loading pattern of human ACL is different from animal models. Many of the published reviews on the ACL focus largely on animal ACL than human ACL. Further, this review article summarizes the issues with autografts and synthetic grafts used so far. Autografts (patellar tendon and hamstring tendon) remains the gold standard as nearly all synthetic grafts introduced for clinical use have been withdrawn from the market. The mechanical strength during the ligamentization of autografts is also highlighted in this work. PMID:29861784

  3. Expression of collagen and related growth factors in rat tendon and skeletal muscle in response to specific contraction types

    PubMed Central

    Heinemeier, K M; Olesen, J L; Haddad, F; Langberg, H; Kjaer, M; Baldwin, K M; Schjerling, P

    2007-01-01

    Acute exercise induces collagen synthesis in both tendon and muscle, indicating an adaptive response in the connective tissue of the muscle–tendon unit. However, the mechanisms of this adaptation, potentially involving collagen-inducing growth factors (such as transforming growth factor-β-1 (TGF-β-1)), as well as enzymes related to collagen processing, are not clear. Furthermore, possible differential effects of specific contraction types on collagen regulation have not been investigated. Female Sprague–Dawley rats were subjected to 4 days of concentric, eccentric or isometric training (n = 7–9 per group) of the medial gastrocnemius, by stimulation of the sciatic nerve. RNA was extracted from medial gastrocnemius and Achilles tendon tissue 24 h after the last training bout, and mRNA levels for collagens I and III, TGF-β-1, connective tissue growth factor (CTGF), lysyl oxidase (LOX), metalloproteinases (MMP-2 and -9) and their inhibitors (TIMP-1 and 2) were measured by Northern blotting and/or real-time PCR. In tendon, expression of TGF-β-1 and collagens I and III (but not CTGF) increased in response to all types of training. Similarly, enzymes/factors involved in collagen processing were induced in tendon, especially LOX (up to 37-fold), which could indicate a loading-induced increase in cross-linking of tendon collagen. In skeletal muscle, a similar regulation of gene expression was observed, but in contrast to the tendon response, the effect of eccentric training was significantly greater than the effect of concentric training on the expression of several transcripts. In conclusion, the study supports an involvement of TGF-β-1 in loading-induced collagen synthesis in the muscle–tendon unit and importantly, it indicates that muscle tissue is more sensitive than tendon to the specific mechanical stimulus. PMID:17540706

  4. Expression of collagen and related growth factors in rat tendon and skeletal muscle in response to specific contraction types.

    PubMed

    Heinemeier, K M; Olesen, J L; Haddad, F; Langberg, H; Kjaer, M; Baldwin, K M; Schjerling, P

    2007-08-01

    Acute exercise induces collagen synthesis in both tendon and muscle, indicating an adaptive response in the connective tissue of the muscle-tendon unit. However, the mechanisms of this adaptation, potentially involving collagen-inducing growth factors (such as transforming growth factor-beta-1 (TGF-beta-1)), as well as enzymes related to collagen processing, are not clear. Furthermore, possible differential effects of specific contraction types on collagen regulation have not been investigated. Female Sprague-Dawley rats were subjected to 4 days of concentric, eccentric or isometric training (n = 7-9 per group) of the medial gastrocnemius, by stimulation of the sciatic nerve. RNA was extracted from medial gastrocnemius and Achilles tendon tissue 24 h after the last training bout, and mRNA levels for collagens I and III, TGF-beta-1, connective tissue growth factor (CTGF), lysyl oxidase (LOX), metalloproteinases (MMP-2 and -9) and their inhibitors (TIMP-1 and 2) were measured by Northern blotting and/or real-time PCR. In tendon, expression of TGF-beta-1 and collagens I and III (but not CTGF) increased in response to all types of training. Similarly, enzymes/factors involved in collagen processing were induced in tendon, especially LOX (up to 37-fold), which could indicate a loading-induced increase in cross-linking of tendon collagen. In skeletal muscle, a similar regulation of gene expression was observed, but in contrast to the tendon response, the effect of eccentric training was significantly greater than the effect of concentric training on the expression of several transcripts. In conclusion, the study supports an involvement of TGF-beta-1 in loading-induced collagen synthesis in the muscle-tendon unit and importantly, it indicates that muscle tissue is more sensitive than tendon to the specific mechanical stimulus.

  5. [Tibial press-fit fixation of flexor tendons for reconstruction of the anterior cruciate ligament].

    PubMed

    Ettinger, M; Liodakis, E; Haasper, C; Hurschler, C; Breitmeier, D; Krettek, C; Jagodzinski, M

    2012-09-01

    Press-fit fixation of hamstring tendon autografts for anterior cruciate ligament reconstruction is an interesting technique because no hardware is necessary. This study compares the biomechanical properties of press-fit fixations to an interference screw fixation. Twenty-eight human cadaveric knees were used for hamstring tendon explantation. An additional bone block was harvested from the tibia. We used 28 porcine femora for graft fixation. Constructs were cyclically stretched and then loaded until failure. Maximum load to failure, stiffness and elongation during failure testing and cyclic loading were investigated. The maximum load to failure was 970±83 N for the press-fit tape fixation (T), 572±151 N for the bone bridge fixation (TS), 544±109 N for the interference screw fixation (I), 402±77 N for the press-fit suture fixation (S) and 290±74 N for the bone block fixation technique (F). The T fixation had a significantly better maximum load to failure compared to all other techniques (p<0.001). This study demonstrates that a tibial press-fit technique which uses an additional bone block has better maximum load to failure results compared to a simple interference screw fixation.

  6. Specialization of tendon mechanical properties results from interfascicular differences

    PubMed Central

    Thorpe, Chavaunne T.; Udeze, Chineye P.; Birch, Helen L.; Clegg, Peter D.; Screen, Hazel R. C.

    2012-01-01

    Tendons transfer force from muscle to bone. Specific tendons, including the equine superficial digital flexor tendon (SDFT), also store and return energy. For efficient function, energy-storing tendons need to be more extensible than positional tendons such as the common digital extensor tendon (CDET), and when tested in vitro have a lower modulus and failure stress, but a higher failure strain. It is not known how differences in matrix organization contribute to distinct mechanical properties in functionally different tendons. We investigated the properties of whole tendons, tendon fascicles and the fascicular interface in the high-strain energy-storing SDFT and low-strain positional CDET. Fascicles failed at lower stresses and strains than tendons. The SDFT was more extensible than the CDET, but SDFT fascicles failed at lower strains than CDET fascicles, resulting in large differences between tendon and fascicle failure strain in the SDFT. At physiological loads, the stiffness at the fascicular interface was lower in the SDFT samples, enabling a greater fascicle sliding that could account for differences in tendon and fascicle failure strain. Sliding between fascicles prior to fascicle extension in the SDFT may allow the large extensions required in energy-storing tendons while protecting fascicles from damage. PMID:22764132

  7. Specialization of tendon mechanical properties results from interfascicular differences.

    PubMed

    Thorpe, Chavaunne T; Udeze, Chineye P; Birch, Helen L; Clegg, Peter D; Screen, Hazel R C

    2012-11-07

    Tendons transfer force from muscle to bone. Specific tendons, including the equine superficial digital flexor tendon (SDFT), also store and return energy. For efficient function, energy-storing tendons need to be more extensible than positional tendons such as the common digital extensor tendon (CDET), and when tested in vitro have a lower modulus and failure stress, but a higher failure strain. It is not known how differences in matrix organization contribute to distinct mechanical properties in functionally different tendons. We investigated the properties of whole tendons, tendon fascicles and the fascicular interface in the high-strain energy-storing SDFT and low-strain positional CDET. Fascicles failed at lower stresses and strains than tendons. The SDFT was more extensible than the CDET, but SDFT fascicles failed at lower strains than CDET fascicles, resulting in large differences between tendon and fascicle failure strain in the SDFT. At physiological loads, the stiffness at the fascicular interface was lower in the SDFT samples, enabling a greater fascicle sliding that could account for differences in tendon and fascicle failure strain. Sliding between fascicles prior to fascicle extension in the SDFT may allow the large extensions required in energy-storing tendons while protecting fascicles from damage.

  8. The effect of bone tunnel dilation versus extraction drilling on the initial fixation strength of press-fit anterior cruciate ligament reconstruction.

    PubMed

    Dargel, Jens; Schmidt-Wiethoff, Rüdiger; Brüggemann, Gert-Peter; Koebke, Jürgen

    2007-11-01

    Serial dilation of the bone tunnel has been reported to create a tighter graft-tunnel fit. It was hypothesized that a serial dilation of the femoral bone tunnel would increase the initial fixation strength in press-fit anterior cruciate ligament (ACL) reconstructive surgery. Initial fixation strength of the femoral press-fit fixation technique was investigated in 72 porcine specimens in an ex vivo study by varying the femoral tunnel preparation technique. Extraction-drilling, tunnel dilation by 1 mm and dilation by 2.5 mm were assessed. Initial fixation strength of press-fit fixated patellar tendon-bone grafts was tested within each preparation group conducting a single cycle (and cyclic) load to failure protocol. The resulting tunnel diameter and the porcine femoral bone mineral density were determined using microradiographs and peripheral quantitative CT scans, respectively. Dilating a previously extraction-drilled femoral bone tunnel by 1 mm significantly enhances initial press-fit fixation strength in both single cycle and cyclic load to failure testing when compared to extraction-drilling and tunnel dilation by 2.5 mm. Due to an initial spring-back effect the resulting diameter of the femoral tunnel was underestimated by 3.3% with drilling and 6.7 and 12.2% with dilation by 1 and 2.5 mm, respectively. Volumetric trabecular bone mineral density at the site corresponding to the area of tunnel placement averaged 318 mg/cm(3). Dilating a femoral tunnel that is underdrilled by 1 mm appears to be a reasonable technical procedure in order to enhance initial fixation strength of press-fit ACL graft fixation.

  9. Proximal tibial fracture following anterior cruciate ligament reconstruction surgery: a biomechanical analysis of the tibial tunnel as a stress riser.

    PubMed

    Aldebeyan, Wassim; Liddell, Antony; Steffen, Thomas; Beckman, Lorne; Martineau, Paul A

    2017-08-01

    This is the first biomechanical study to examine the potential stress riser effect of the tibial tunnel or tunnels after ACL reconstruction surgery. In keeping with literature, the primary hypothesis tested in this study was that the tibial tunnel acts as a stress riser for fracture propagation. Secondary hypotheses were that the stress riser effect increases with the size of the tunnel (8 vs. 10 mm), the orientation of the tunnel [standard (STT) vs. modified transtibial (MTT)], and with the number of tunnels (1 vs. 2). Tibial tunnels simulating both single bundle hamstring graft (8 mm) and bone-patellar tendon-bone graft (10 mm) either STT or MTT position, as well as tunnels simulating double bundle (DB) ACL reconstruction (7, 6 mm), were drilled in fourth-generation saw bones. These five experimental groups and a control group consisting of native saw bones without tunnels were loaded to failure on a Materials Testing System to simulate tibial plateau fracture. There were no statistically significant differences in peak load to failure between any of the groups, including the control group. The fracture occurred through the tibial tunnel in 100 % of the MTT tunnels (8 and 10 mm) and 80 % of the DB tunnels specimens; however, the fractures never (0 %) occurred through the tibial tunnel of the standard tunnels (8 or 10 mm) (P = 0.032). In the biomechanical model, the tibial tunnel does not appear to be a stress riser for fracture propagation, despite suggestions to the contrary in the literature. Use of a standard, more vertical tunnel decreases the risk of ACL graft compromise in the event of a fracture. This may help to inform surgical decision making on ACL reconstruction technique.

  10. [Clinical application of peroneal muscles tendon transposition in repair of Achilles tendon rupture].

    PubMed

    Jin, Rihao; Jin, Yu; Fang, Xiulin

    2006-07-01

    To discuss applied anatomy, biomechanics and surgical procedures of long peroneal muscles tendon transposition in repair of occlusive achilles tendon rupture. The blood supply and the morphology of long peroneal muscles tendon were observed in the lower extremity of 50 sides adult specimens and the mechanical tests which stretch load on the tendon were carried out. The methods were designed on the basis of the anatomical characteristics and morphology. Ten patients suffering occlusive Achilles tendon rupture were treated by using long peroneal muscles tendon transposition from March 2001 to July 2004. Among 10 patients, there were 7 males and 3 females, aging 32 to 54 years including 6 cases of jump injury, 2 cases of bruise, 1 case of step vacancy and 1 case of spontaneity injury. The interval between injury and surgery was 6 hours to 7 days in 7 fresh rupture and 21 days to 3 months in 3 old rupture. All cases belonged to occlusive Achilles tendon rupture (8 cases of complete rupture and 2 cases of incomplete rupture). The origin of long peroneal muscles was proximal tibia and fibular head, the end of them was base of first metatarsal bones and medial cuboid. The length of tendon was 13.5 +/- 2.5 cm. The width of origin tendon was 0.9 +/- 0.2 cm and the thickness was 0.3 +/- 0.1 cm; the width on apex of lateral malleolus was 0.7 +/- 0.1 cm and the thickness was 0.4 +/- 0.1 cm, the width on head of cuboid was 0.7 +/- 0.1 cm and the thickness was 0.3 +/- 0.1 cm. The long peroneal muscles tendon had abundant blood supply. The results of mechanical test showed that the biggest load was 2,292.4 +/- 617.3 N on tendon calcaneus, 1,020.4 +/- 175.4 N on long peroneal muscles tendon, 752.0 +/- 165.4 N on peroneus brevis tendon and 938.2 +/- 216.7 N on tibialis posterior tendon. Ten cases of occlusive Achilles tendon rupture achieved healing by first intention and were followed up 18-24 months. No Achilles tendon re-rupture, necrosis of skin or other complications occurred. According to Amerind-holm criterion for curative results, the results were excellent in 7 cases and good in 3 cases and the excellent and good rate was 100%. The long peroneal muscles tendon transposition is a perfect and simple way to repair occlusive Achilles tendon rupture.

  11. Cyclic strain alters the expression and release of angiogenic factors by human tendon cells.

    PubMed

    Mousavizadeh, Rouhollah; Khosravi, Shahram; Behzad, Hayedeh; McCormack, Robert G; Duronio, Vincent; Scott, Alex

    2014-01-01

    Angiogenesis is associated with the tissue changes underlying chronic overuse tendinopathy. We hypothesized that repetitive, cyclic loading of human tendon cells would lead to increased expression and activity of angiogenic factors. We subjected isolated human tendon cells to overuse tensile loading using an in vitro model (1 Hz, 10% equibiaxial strain). We found that mechanically stimulated human tendon cells released factors that promoted in vitro proliferation and tube formation by human umbilical vein endothelial cells (HUVEC). In response to cyclic strain, there was a transient increase in the expression of several angiogenic genes including ANGPTL4, FGF-2, COX-2, SPHK1, TGF-alpha, VEGF-A and VEGF-C, with no change in anti-angiogenic genes (BAI1, SERPINF1, THBS1 and 2, TIMP1-3). Cyclic strain also resulted in the extracellular release of ANGPTL4 protein by tendon cells. Our study is the first report demonstrating the induction of ANGPTL4 mRNA and release of ANGPTL4 protein in response to cyclic strain. Tenocytes may contribute to the upregulation of angiogenesis during the development of overuse tendinopathy.

  12. Cyclic Strain Alters the Expression and Release of Angiogenic Factors by Human Tendon Cells

    PubMed Central

    Mousavizadeh, Rouhollah; Khosravi, Shahram; Behzad, Hayedeh; McCormack, Robert G.; Duronio, Vincent; Scott, Alex

    2014-01-01

    Angiogenesis is associated with the tissue changes underlying chronic overuse tendinopathy. We hypothesized that repetitive, cyclic loading of human tendon cells would lead to increased expression and activity of angiogenic factors. We subjected isolated human tendon cells to overuse tensile loading using an in vitro model (1 Hz, 10% equibiaxial strain). We found that mechanically stimulated human tendon cells released factors that promoted in vitro proliferation and tube formation by human umbilical vein endothelial cells (HUVEC). In response to cyclic strain, there was a transient increase in the expression of several angiogenic genes including ANGPTL4, FGF-2, COX-2, SPHK1, TGF-alpha, VEGF-A and VEGF-C, with no change in anti-angiogenic genes (BAI1, SERPINF1, THBS1 and 2, TIMP1-3). Cyclic strain also resulted in the extracellular release of ANGPTL4 protein by tendon cells. Our study is the first report demonstrating the induction of ANGPTL4 mRNA and release of ANGPTL4 protein in response to cyclic strain. Tenocytes may contribute to the upregulation of angiogenesis during the development of overuse tendinopathy. PMID:24824595

  13. Biomechanical effects of a 2 suture-pass medial inter-implant mattress on transosseous-equivalent rotator cuff repair and considerations for a "technical efficiency ratio".

    PubMed

    Park, Maxwell C; Peterson, Alexander; Patton, John; McGarry, Michelle H; Park, Chong J; Lee, Thay Q

    2014-03-01

    Rotator cuff repair involving fewer tendon suture passes without compromising biomechanical performance would represent a technical advancement. An inter-implant "medial pulley-mattress" transosseous-equivalent (MP-TOE) repair requiring fewer tendon suture-passes was hypothesized to provide equivalent biomechanical characteristics compared to the control. In 6 human cadaveric shoulders, a transosseous-equivalent (TOE) repair (control) was performed utilizing 2 separate medial mattresses resulting in 4 tendon-bridging sutures. In 6 matched-pairs, 2 single-loaded anchors were used to create a medial inter-implant mattress construct (all sutures shuttled in 1 tendon pass per anchor)-after knot-tying, the same tendon-bridging pattern as the control was created. A materials testing machine cyclically loaded each repair from 10-180 N for 30 cycles; each repair subsequently underwent failure testing. Gap and strain were measured with a video digitizing system. A "technical efficiency ratio" (TER) was defined as: (#knots + #suture passes + #suture limbs)/#fixation points. Cyclic and failure testing demonstrated no significant differences between constructs. Gap formation at cycle 30 was 5.3 ± 0.8 mm (TOE) and 5.0 ± 0.3 mm (MP-TOE) (P = .62). Cycle 30 anterior strain values were -16.0 ± 7.3% (TOE) and -15.8 ± 6.6% (MP-TOE) (P = .99). Yield loads were 208.7 ± 2.7 N (TOE) and 204.0 ± 1.3 N (MP-TOE) (P = .17). Mode of failure demonstrated less tendon cut-out with the MP-TOE repair. The MP-TOE repair has a TER of 2.0 vs 2.5 for the control. The MP-TOE repair requiring fewer tendon suture passes, yet creating an additional inter-implant mattress configuration, is biomechanically equivalent to the original TOE technique, and may limit failure with improved medial load-sharing capacity. A TER may help quantify technical ease and help standardize comparisons between repair techniques. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.

  14. Efficacy of supraspinatus tendon repair using mesenchymal stem cells along with a collagen I scaffold.

    PubMed

    Tornero-Esteban, Pilar; Hoyas, José Antonio; Villafuertes, Esther; Rodríguez-Bobada, Cruz; López-Gordillo, Yamila; Rojo, Francisco J; Guinea, Gustavo V; Paleczny, Anna; Lópiz-Morales, Yaiza; Rodriguez-Rodriguez, Luis; Marco, Fernando; Fernández-Gutiérrez, Benjamín

    2015-08-14

    Our main objective was to biologically improve rotator cuff healing in an elderly rat model using mesenchymal stem cells (MSCs) in combination with a collagen membrane and compared against other current techniques. A chronic rotator cuff tear injury model was developed by unilaterally detaching the supraspinatus (SP) tendons of Sprague-Dawley rats. At 1 month postinjury, the tears were repaired using one of the following techniques: (a) classical surgery using sutures (n = 12), (b) type I collagen membranes (n = 15), and (c) type I collagen membranes + 1 × 106 allogeneic MSCs (n = 14). Lesion restoration was evaluated at 1, 2, and 3 months postinjury based on biomechanical criteria. Continuous variables were described using mean and standard deviation (SD). To analyse the effect of the different surgical treatments in the repaired tendons' biomechanical capabilities (maximum load, stiffness, and deformity), a two-way ANOVA model was used, introducing an interaction between such factor and time (1, 2, and 3 months postinjury). With regard to maximum load, we observed an almost significant interaction between treatment and time (F = 2.62, df = 4, p = 0.053). When we analysed how this biomechanical capability changed with time for each treatment, we observed that repair with OrthADAPT and MSCs was associated with a significant increase in maximum load (p = 0.04) between months 1 and 3. On the other hand, when we compared the different treatments among themselves at different time points, we observed that the repair with OrthADAPT and MSCs has associated with a significant higher maximum load, when compared with the use of suture, but only at 3 months (p = 0.014). With regard to stiffness and deformity, no significant interaction was observed (F = 1.68, df = 4, p = 0.18; F = 0.40, df = 4, p = 0.81; respectively). The implantation of MSCs along with a collagen I scaffold into surgically created tendon defects is safe and effective. MSCs improved the tendon's maximum load over time, indicating that MSCs could help facilitate the dynamic process of tendon repair.

  15. Triple-Loaded Single-Row Versus Suture-Bridge Double-Row Rotator Cuff Tendon Repair With Platelet-Rich Plasma Fibrin Membrane: A Randomized Controlled Trial.

    PubMed

    Barber, F Alan

    2016-05-01

    To compare the structural healing and clinical outcomes of triple-loaded single-row with suture-bridging double-row repairs of full-thickness rotator cuff tendons when both repair constructs are augmented with platelet-rich plasma fibrin membrane. A prospective, randomized, consecutive series of patients diagnosed with full-thickness rotator cuff tears no greater than 3 cm in anteroposterior length were treated with a triple-loaded single-row (20) or suture-bridging double-row (20) repair augmented with platelet-rich plasma fibrin membrane. The primary outcome measure was cuff integrity by magnetic resonance imaging (MRI) at 12 months postoperatively. Secondary clinical outcome measures were American Shoulder and Elbow Surgeons, Rowe, Simple Shoulder Test, Constant, and Single Assessment Numeric Evaluation scores. The mean MRI interval was 12.6 months (range, 12-17 months). A total of 3 of 20 single-row repairs and 3 of 20 double-row repairs (15%) had tears at follow-up MRI. The single-row group had re-tears in 1 single tendon repair and 2 double tendon repairs. All 3 tears failed at the original attachment site (Cho type 1). In the double-row group, re-tears were found in 3 double tendon repairs. All 3 tears failed medial to the medial row near the musculotendinous junction (Cho type 2). All clinical outcome measures were significantly improved from the preoperative level (P < .0001), but there was no statistical difference between groups postoperatively. There is no MRI difference in rotator cuff tendon re-tear rate at 12 months postsurgery between a triple-loaded single-row repair or a suture-bridging double-row repair when both are augmented with platelet-rich plasma fibrin membrane. No difference could be demonstrated between these repairs on clinical outcome scores. I, Prospective randomized study. Copyright © 2016 Arthroscopy Association of North America. All rights reserved.

  16. Successful anterior cruciate ligament reconstruction and meniscal repair in osteogenesis imperfecta.

    PubMed

    Park, Jae-Young; Cho, Tae-Joon; Lee, Myung Chul; Han, Hyuk-Soo

    2018-03-20

    A case of anterior cruciate ligament (ACL) reconstruction with meniscal repair in an osteogenesis imperfecta patient is reported. A 24-year-old female with osteogenesis imperfecta type 1a suffered from a valgus extension injury resulting in tear of ACL and medial meniscus. She underwent an arthroscopic-assisted ACL reconstruction and medial meniscus repair. Meniscal tear at the menisco-capsular junction of the posterior horn of medial meniscus was repaired with three absorbable sutures via inside-out technique. ACL reconstruction was then performed with a bone-patellar tendon-bone allograft. The patient was followed up for 1 year with intact ACL grafts and healed medial meniscus. This case report showed that successful ACL reconstruction and meniscal repair is possible in an osteogenesis imperfecta patient.Level of evidence V.

  17. Triceps surae muscle-tendon properties in older endurance- and sprint-trained athletes.

    PubMed

    Stenroth, Lauri; Cronin, Neil J; Peltonen, Jussi; Korhonen, Marko T; Sipilä, Sarianna; Finni, Taija

    2016-01-01

    Previous studies have shown that aging is associated with alterations in muscle architecture and tendon properties (Morse CI, Thom JM, Birch KM, Narici MV. Acta Physiol Scand 183: 291-298, 2005; Narici MV, Maganaris CN, Reeves ND, Capodaglio P. J Appl Physiol 95: 2229-2234, 2003; Stenroth L, Peltonen J, Cronin NJ, Sipila S, Finni T. J Appl Physiol 113: 1537-1544, 2012). However, the possible influence of different types of regular exercise loading on muscle architecture and tendon properties in older adults is poorly understood. To address this, triceps surae muscle-tendon properties were examined in older male endurance (OE, n = 10, age = 74.0 ± 2.8 yr) and sprint runners (OS, n = 10, age = 74.4 ± 2.8 yr), with an average of 42 yr of regular training experience, and compared with age-matched [older control (OC), n = 33, age = 74.8 ± 3.6 yr] and young untrained controls (YC, n = 18, age = 23.7 ± 2.0 yr). Compared with YC, Achilles tendon cross-sectional area (CSA) was 22% (P = 0.022), 45% (P = 0.001), and 71% (P < 0.001) larger in OC, OE, and OS, respectively. Among older groups, OS had significantly larger tendon CSA compared with OC (P = 0.033). No significant between-group differences were observed in Achilles tendon stiffness. In older groups, Young's modulus was 31-44%, and maximal tendon stress 44-55% lower, than in YC (P ≤ 0.001). OE showed shorter soleus fascicle length than both OC (P < 0.05) and YC (P < 0.05). These data suggest that long-term running does not counteract the previously reported age-related increase in tendon CSA, but, instead, may have an additive effect. The greatest Achilles tendon CSA was observed in OS followed by OE and OC, suggesting that adaptation to running exercise is loading intensity dependent. Achilles tendon stiffness was maintained in older groups, even though all older groups displayed larger tendon CSA and lower tendon Young's modulus. Shorter soleus muscle fascicles in OE runners may be an adaptation to life-long endurance running. Copyright © 2016 the American Physiological Society.

  18. [HEALING MODEL RESEARCH OF ROTATOR CUFF INJURY IN CANINE].

    PubMed

    Ye, Wei; Bao, Nirong; Zhaq, Jianning

    2016-04-01

    To compare the difference of rotator cuff healing between different types of injury andbetween different repair methods, and to explore the animal model to accurately simulate the restorative process afterrepair of rotator cuff injury. Twelve adult male beagle dogs (weighing, 10-15 kg) were divided into 3 groups (n = 4) according to different processing methods: acute rotator cuff injury+Mason-Allen suture repair (group A), huge rotator cuff injury+Mason-Allen suture repair (group B), and huge rotator cuff injury+Mason-Allen combined with autogenous semitendinosus expansion suture repair (group C). The external fixation was used for immobilization after repair. After operation, the general situation of the animals was observed, and the infraspinatus tendon was harvested for gross observation at 6 weeks after operation. The biomechanical test of limit load and histological observation of tendon fibers were carried out. All the animals survived to the end of the experiment. All incisions healed well and no infection occurred. Gross observation showed more scar tissues at the end of infraspinatus muscle tendon than normal tendon in group A; no obvious tendon tissue was observed at the end of infraspinatus muscle tendon in group B; the infraspinatus muscle tendon was covered with some white scar tissue, but the tendon and the general direction could be observed in group C. The limit load of groups A, B, and C were (223.75 ± 24.28), (159.25 ± 34.87), and (233.25 ± 14.24) N respectively, group B was significantly lower than groups A and C (P < 0.05), and no significant differnce was found between group A and group C (P > 0.05). Histological observation showed normal arrangement of tendon fibers in group A; tendon fibers arranged disorderly in group B and tendon cells were significantly less than those of group A; tendon fibers arranged in neat in group C and tendon cells were more than those of group B. Canine autologous semitendinosus expansion repair of massive rotator cuff injury immobilization model can better simulate the clinical rotator cuff injury healing process, so it can be used as an ideal animal model for related research.

  19. Effect of tendon tensioning: an in vitro study in porcine extensor tendons.

    PubMed

    Figueroa, David; Calvo, Rafael; Vaisman, Alex; Meleán, Patricio; Figueroa, Francisco

    2010-06-01

    Graft tensioning is a controversial issue in anterior cruciate ligament reconstruction (ACLR) that has not achieved consensus between peers. The purpose of this study is to determine if after tensioning tendon length and resistance to maximal load changes. We performed an in vitro study with 50 porcine extensors tendons. The first group (P=25) was tensioned with 80 N (19.97 lb) for 10 min, using an ACL graft preparation board. The second group (C=25) was used as control and was not tensioned. The average initial (groups P and C) and post tensioning tendon length (group C) were measured; the average initial and post tensioning tendon diameter were measured as well. All samples were fixated in a tube-clamp system connected to a tension sensor. The samples were stressed with continuous and progressive tension until ultimate failure at maximum load (UFML) occurs. The initial mean length was: P before tensioning=13.4 mm+/-1.4 mm (range 10.5-16.5); P after tensioning=13.8 mm+/-1.4 mm (range 11.5-16.5); C=13 mm+/-1.35 mm (p=0.005). The mean diameter was: P=5.6 mm (4.5-6); C=5.5 mm (range 4.5-6) (p>0.05). The UFML was: P=189.7 N (114-336); C=229.9 N (143-365) (p=0.029). Tendon tensioning with 80 N for 10 min produced 3% average elongation. These could be beneficial in ACLR since tendon tensioning decreases elongation of the graft after fixation. Regardless, tendon tensioning is not innocuous since it diminishes their resistance when continuously stressed until complete failure occurs.

  20. Medial versus lateral supraspinatus tendon properties: implications for double-row rotator cuff repair.

    PubMed

    Wang, Vincent M; Wang, Fan Chia; McNickle, Allison G; Friel, Nicole A; Yanke, Adam B; Chubinskaya, Susan; Romeo, Anthony A; Verma, Nikhil N; Cole, Brian J

    2010-12-01

    Rotator cuff repair retear rates range from 25% to 90%, necessitating methods to improve repair strength. Although numerous laboratory studies have compared single-row with double-row fixation properties, little is known regarding regional (ie, medial vs lateral) suture retention properties in intact and torn tendons. A torn supraspinatus tendon will have reduced suture retention properties on the lateral aspect of the tendon compared with the more medial musculotendinous junction. Controlled laboratory study. Human supraspinatus tendons (torn and intact) were randomly assigned for suture retention mechanical testing, ultrastructural collagen fibril analysis, or histologic testing after suture pullout testing. For biomechanical evaluation, sutures were placed either at the musculotendinous junction (medial) or 10 mm from the free margin (lateral), and tendons were elongated to failure. Collagen fibril assessments were performed using transmission electron microscopy. Intact tendons showed no regional differences with respect to suture retention properties. In contrast, among torn tendons, the medial region exhibited significantly higher stiffness and work values relative to the lateral region. For the lateral region, work to 10-mm displacement (1592 ± 261 N-mm) and maximum load (265 ± 44 N) for intact tendons were significantly higher (P < .05) than that of torn tendons (1086 ± 388 N-mm and 177 ± 71 N, respectively). For medial suture placement, maximum load, stiffness, and work of intact and torn tendons were similar (P > .05). Regression analyses for the intact and torn groups revealed generally low correlations between donor age and the 3 biomechanical indices. For both intact and torn tendons, the mean fibril diameter and area density were greater in the medial region relative to the lateral (P ≤ .05). In the lateral tendon, but not the medial region, torn specimens showed a significantly lower fibril area fraction (48.3% ± 3.8%) than intact specimens (56.7% ± 3.6%, P < .05). Superior pullout resistance of medially placed sutures may provide a strain shielding effect for the lateral row after double-row repair. Larger diameter collagen fibrils as well as greater fibril area fraction in the medial supraspinatus tendon may provide greater resistance to suture migration. While clinical factors such as musculotendinous integrity warrant strong consideration for surgical decision making, the present ultrastructural and biomechanical results appear to provide a scientific rationale for double-row rotator cuff repair where sutures are placed more medially at the muscle-tendon junction.

  1. Probing multi-scale mechanical damage in connective tissues using X-ray diffraction.

    PubMed

    Bianchi, Fabio; Hofmann, Felix; Smith, Andrew J; Thompson, Mark S

    2016-11-01

    The accumulation of microstructural collagen damage following repetitive loading is linked to painful and debilitating tendon injuries. As a hierarchical, semi-crystalline material, collagen mechanics can be studied using X-ray diffraction. The aim of the study was to describe multi-structural changes in tendon collagen following controlled plastic damage (5% permanent strain). We used small angle X-ray scattering (SAXS) to interrogate the spacing of collagen molecules within a fibril, and wide angle X-ray scattering (WAXS) to measure molecular strains under macroscopic loading. Simultaneous recordings of SAXS and WAXS patterns, together with whole-tissue strain in physiologically hydrated rat-tail tendons were made during increments of in situ tensile loading. Results showed that while tissue level modulus was unchanged, fibril modulus decreased significantly, and molecular modulus significantly increased. Further, analysis of higher order SAXS peaks suggested structural changes in the gap and overlap regions, possibly localising the damage to molecular cross-links. Our results provide new insight into the fundamental damage processes at work in collagenous tissues and point to new directions for their mitigation and repair. This article reports the first in situ loading synchrotron studies on mechanical damage in collagenous tissues. We provide new insight into the nano- and micro-structural mechanisms of damage processes. Pre-damaged tendons showed differential alteration of moduli at macro, micro and nano-scales as measured using X-ray scattering techniques. Detailed analysis of higher order diffraction peaks suggested damage is localised to molecular cross-links. The results are consistent with previous X-ray scattering studies of tendons and also with recent thermal stability studies on damaged material. Detailed understanding of damage mechanisms is essential in the development of new therapies promoting tissue repair. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  2. A cross sectional study of 100 athletes with jumper's knee managed conservatively and surgically. The Victorian Institute of Sport Tendon Study Group.

    PubMed Central

    Cook, J L; Khan, K M; Harcourt, P R; Grant, M; Young, D A; Bonar, S F

    1997-01-01

    OBJECTIVES: Jumper's knee causes significant morbidity in athletes of all standards. However, there are few reference data on the clinical course of this condition in a large number of patients, and the aim of this study was to rectify this. METHODS: A retrospective study of the course of jumper's knee in 100 athletes who presented to a sports medicine clinic over a nine year period was carried out. Subjects completed a questionnaire designed to collect details of sport participation, symptoms, and time out of sport. Ultrasonographic results were recorded from the radiologists' reports. Histopathological results were obtained for patients who had surgery. RESULTS: Forty eight subjects recalled that symptoms of jumper's knee began before the age of 20 years. Symptoms prevented 33 from participating in sport for more than six months, and 18 of these were sidelined for more than 12 months. Forty nine of the subjects had two or more separate episodes of symptoms. Ultrasonography showed a characteristics hypoechoic region at the junction of the inferior pole of the patella and the deep surface of the patellar tendon. Histopathological examination showed separation and disruption of collagen fibres on polarisation light microscopy and an increase in mucoid ground substance consistent with damage of tendon collagen without inflammation. CONCLUSIONS: Jumper's knee has the potential to be a debilitating condition for a sports person. About 33% of athletes presenting to a sports medicine clinic with jumper's knee were unable to return to sport for more than six months. Images Figure 1 Figure 2 Figure 3 Figure 4 PMID:9429013

  3. Autologous tenocyte injection for the treatment of severe, chronic resistant lateral epicondylitis: a pilot study.

    PubMed

    Wang, Allan; Breidahl, William; Mackie, Katherine E; Lin, Zhen; Qin, An; Chen, Jimin; Zheng, Ming H

    2013-12-01

    Severe chronic lateral epicondylitis (LE) is associated with degenerative tendon changes, extracellular matrix breakdown, and tendon cell loss. On the basis of positive outcomes from preclinical studies, this study is the first clinical trial of autologous tenocyte injection (ATI) on severe tendinopathy associated with chronic LE. Autologous tenocyte injection is a safe and effective procedure that enables a reduction in pain and improvement in function in resistant LE. Case series; Level of evidence, 4. Patients with severe refractory LE underwent clinical evaluation and magnetic resonance imaging (MRI) before intervention. A patellar tendon needle biopsy was performed under local anesthetic, and tendon cells were expanded by in vitro culture. Tenocytes used for the injection were characterized by flow cytometry and real-time polymerase chain reaction. Autologous tenocytes were injected into the site of tendinopathy identified at the origin of the extensor carpi radialis brevis tendon under ultrasound guidance on a single occasion. Patients underwent serial clinical evaluations and repeat MRI at 12 months after intervention. A total of 20 consecutive patients were included in the study. Three patients withdrew consent after enrollment and before ATI. No adverse event was reported at either biopsy or injection sites. Furthermore, no infection or excessive fibroblastic reaction was found in any patient at the injection site. Clinical evaluation revealed an improvement in mean visual analog scale scores, for a maximum pain score from 5.94 at the initial assessment to 0.76 at 12 months (P < .001). Mean quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) and grip strength scores also significantly improved over the 12-month follow-up (QuickDASH score, 45.88 [baseline] to 3.84; grip strength, 20.17 kg [baseline] to 37.38 kg; P < .001). With use of a validated MRI scoring system, the grade of tendinopathy at the common extensor origin improved significantly by 12 months (P < .001). One patient elected to proceed to surgery 3 months after ATI following a reinjury at work. In this study, patients with chronic LE who had previously undergone an unsuccessful full course of nonoperative treatment showed significantly improved clinical function and structural repair at the origin of the common extensor tendon after ATI. This novel treatment is encouraging for the treatment of tendinopathy and warrants further evaluation.

  4. A biomechanical comparison of single and double-row fixation in arthroscopic rotator cuff repair.

    PubMed

    Smith, Christopher D; Alexander, Susan; Hill, Adam M; Huijsmans, Pol E; Bull, Anthony M J; Amis, Andrew A; De Beer, Joe F; Wallace, Andrew L

    2006-11-01

    The optimal method for arthroscopic rotator cuff repair is not yet known. The hypothesis of the present study was that a double-row repair would demonstrate superior static and cyclic mechanical behavior when compared with a single-row repair. The specific aims were to measure gap formation at the bone-tendon interface under static creep loading and the ultimate strength and mode of failure of both methods of repair under cyclic loading. A standardized tear of the supraspinatus tendon was created in sixteen fresh cadaveric shoulders. Arthroscopic rotator cuff repairs were performed with use of either a double-row technique (eight specimens) or a single-row technique (eight specimens) with nonabsorbable sutures that were double-loaded on a titanium suture anchor. The repairs were loaded statically for one hour, and the gap formation was measured. Cyclic loading to failure was then performed. Gap formation during static loading was significantly greater in the single-row group than in the double-row group (mean and standard deviation, 5.0 +/- 1.2 mm compared with 3.8 +/- 1.4 mm; p < 0.05). Under cyclic loading, the double-row repairs failed at a mean of 320 +/- 96.9 N whereas the single-row repairs failed at a mean of 224 +/- 147.9 N (p = 0.058). Three single-row repairs and three double-row repairs failed as a result of suture cut-through. Four single-row repairs and one double-row repair failed as a result of anchor or suture failure. The remaining five repairs did not fail, and a midsubstance tear of the tendon occurred. Although more technically demanding, the double-row technique demonstrates superior resistance to gap formation under static loading as compared with the single-row technique. A double-row reconstruction of the supraspinatus tendon insertion may provide a more reliable construct than a single-row repair and could be used as an alternative to open reconstruction for the treatment of isolated tears.

  5. A Comparative Biomechanical Analysis of 2 Double-Row, Distal Triceps Tendon Repairs

    PubMed Central

    Dorweiler, Matthew A.; Van Dyke, Rufus O.; Siska, Robert C.; Boin, Michael A.; DiPaola, Mathew J.

    2017-01-01

    Background: Triceps tendon ruptures are rare orthopaedic injuries that almost always require surgical repair. This study tests the biomechanical properties of an original anchorless double-row triceps repair against a previously reported knotless double-row repair. Hypothesis: The anchorless double-row triceps repair technique will yield similar biomechanical properties when compared with the knotless double-row repair technique. Study Design: Controlled laboratory study. Methods: Eighteen cadaver arms were randomized into 2 groups. One group received the anchorless repair and the other received the knotless anchor repair. A materials testing system (MTS) machine was used to cycle the repaired arms from 0° to 90° with a 2.5-pound weight for 1500 cycles at 0.25 Hz. Real-time displacement of the tendon was measured during cycling using a probe. Load to failure was performed after completion of cyclic loading. Results: The mean displacement with the anchorless technique was 0.77 mm (SD, 0.25 mm) at 0° (full elbow extension) and 0.76 mm (SD, 0.38 mm) at 90° (elbow flexion). The mean displacement with the anchored technique was 0.83 mm (SD, 0.57 mm) at 0° and 1.01 mm (SD, 0.62 mm) at 90°. There was no statistically significant difference for tendon displacement at 0º (P = .75) or 90º (P = .31). The mean load to failure with the anchorless technique was 618.9 N (SD, 185.6 N), while it was 560.5 N (SD, 154.1 N) with the anchored technique, again with no statistically significant difference (P = .28). Conclusion: Our anchorless double-row triceps repair technique yields comparable biomechanical properties to previously described double-row triceps tendon repair techniques, with the added benefit of avoiding the cost of suture anchors. Clinical Relevance: This anchorless double-row triceps tendon repair can be considered as an acceptable alternative to a knotless anchor repair for triceps tendon ruptures. PMID:28607942

  6. A Comparative Biomechanical Analysis of 2 Double-Row, Distal Triceps Tendon Repairs.

    PubMed

    Dorweiler, Matthew A; Van Dyke, Rufus O; Siska, Robert C; Boin, Michael A; DiPaola, Mathew J

    2017-05-01

    Triceps tendon ruptures are rare orthopaedic injuries that almost always require surgical repair. This study tests the biomechanical properties of an original anchorless double-row triceps repair against a previously reported knotless double-row repair. The anchorless double-row triceps repair technique will yield similar biomechanical properties when compared with the knotless double-row repair technique. Controlled laboratory study. Eighteen cadaver arms were randomized into 2 groups. One group received the anchorless repair and the other received the knotless anchor repair. A materials testing system (MTS) machine was used to cycle the repaired arms from 0° to 90° with a 2.5-pound weight for 1500 cycles at 0.25 Hz. Real-time displacement of the tendon was measured during cycling using a probe. Load to failure was performed after completion of cyclic loading. The mean displacement with the anchorless technique was 0.77 mm (SD, 0.25 mm) at 0° (full elbow extension) and 0.76 mm (SD, 0.38 mm) at 90° (elbow flexion). The mean displacement with the anchored technique was 0.83 mm (SD, 0.57 mm) at 0° and 1.01 mm (SD, 0.62 mm) at 90°. There was no statistically significant difference for tendon displacement at 0º ( P = .75) or 90º ( P = .31). The mean load to failure with the anchorless technique was 618.9 N (SD, 185.6 N), while it was 560.5 N (SD, 154.1 N) with the anchored technique, again with no statistically significant difference ( P = .28). Our anchorless double-row triceps repair technique yields comparable biomechanical properties to previously described double-row triceps tendon repair techniques, with the added benefit of avoiding the cost of suture anchors. This anchorless double-row triceps tendon repair can be considered as an acceptable alternative to a knotless anchor repair for triceps tendon ruptures.

  7. Health monitoring of prestressing tendons in post-tensioned concrete structures

    NASA Astrophysics Data System (ADS)

    Salamone, Salvatore; Bartoli, Ivan; Nucera, Claudio; Phillips, Robert; Lanza di Scalea, Francesco

    2011-04-01

    Currently 90% of bridges built in California are post-tensioned box-girder. In such structures the steel tendons are the main load-carrying components. The loss of prestress, as well as the presence of defects or the tendon breakage, can be catastrophic for the entire structure. Unfortunately, today there is no well-established method for the monitoring of prestressing (PS) tendons that can provide simultaneous information related to the presence of defects and the level of prestress in a continuous, real time manner. If such a monitoring system were available, considerable savings would be achieved in bridge maintenance since repairs would be implemented in a timely manner without traffic disruptions. This paper presents a health monitoring system for PS tendons in post-tensioned structures of interest to Caltrans. Such a system uses ultrasonic guided waves and embedded sensors to provide simultaneously and in real time, (a) measurements of the level of applied prestress, and (b) defect detection at early grow stages. The proposed PS measurement technique exploits the sensitivity of ultrasonic waves to the inter-wire contact developing in a multi-wire strand as a function of prestress level. In particular the nonlinear ultrasonic behavior of the tendon under changing levels of prestress is monitored by tracking higher-order harmonics at (nω) arising under a fundamental guided-wave excitation at (ω). Moreover this paper also present real-time damage detection and location in post-tensioned bridge joints using Acoustic Emission techniques. Experimental tests on large-scale single-tendon PT joint specimens, subjected to multiple load cycles, will be presented to validate the monitoring of PS loads (through nonlinear ultrasonic probing) and the monitoring of damage progression and location (through acoustic emission techniques). Issues and potential for the use of such techniques to monitor post-tensioned bridges in the field will be discussed.

  8. Biomechanical cadaveric comparison of patellar ligament suture protected by a steel cable versus a synthetic cable.

    PubMed

    Bouget, P; Breque, C; Beranger, J S; Faure, J P; Khiami, F; Vendeuvre, T

    2017-12-01

    Purpose and hypothesis: Patellar ligament rupture is a rare disabling pathology requiring a surgical ligament suture protected by a frame. The gold standard is the steel cable, but its rigidity and the necessity of a surgical re-intervention for its removal render it unsatisfactory. The objective of this paper is to quantify the mechanical protection provided by the terylene® in comparison with steel. Twenty-four knees of 12 fresh frozen cadaveric subjects were divided into 2 homogeneous groups (terylene and steel) of 12 knees (mean age = 69.3 years). Proximal ligament repair was performed according to a three-tunnel transosseous reinsertion technique. Mechanical tests were performed in flexion to simulate movement of the knee. The interligament gap and the amplitude angulation of the knee were measured by a system of extensometer and optical goniometer. Mechanical analysis permitted calculation of flexion amplitude for a ligament gap of 1 and 2 mm taking as initial angle the adjusting angle of pretension of the protection frame. Study of deformations of frames was performed. Statistical analysis was performed with a Wilcoxon Mann Whitney test. There is no significant difference in protection of the ligament suture between the "terylene" and "steel" groups. Mean flexion amplitudes (mΔF) show no significant differences between the 2 groups for a distension of the suture of 1 mm (m ΔF terylene1 = 4.74 °; mΔF steel1 = 5.91°; p = 0.198) and 2 mm (mΔF terylene2 = 8.71°; mΔF steel2 = 10.41°; p = 0.114). Elastic deformation of terylene was significantly greater than that of steel (p = 0.0004). Suture protection of the patellar ligament by a terylene wire is not significantly different from that provided by steel frame. The elastic properties of terylene and absence of a need for re intervention to secure its removal lead us towards its use in acute ruptures of the patellar ligament. The main limits involve the properties of the chain extenders with no contraction/muscle shortening and partial dehydration of tendons and ligaments and the mean age of 69.3 years. Level 5.

  9. Enthesis fibrocartilage cells originate from a population of Hedgehog-responsive cells modulated by the loading environment.

    PubMed

    Schwartz, Andrea G; Long, Fanxin; Thomopoulos, Stavros

    2015-01-01

    Tendon attaches to bone across a specialized tissue called the enthesis. This tissue modulates the transfer of muscle forces between two materials, i.e. tendon and bone, with vastly different mechanical properties. The enthesis for many tendons consists of a mineralized graded fibrocartilage that develops postnatally, concurrent with epiphyseal mineralization. Although it is well described that the mineralization and development of functional maturity requires muscle loading, the biological factors that modulate enthesis development are poorly understood. By genetically demarcating cells expressing Gli1 in response to Hedgehog (Hh) signaling, we discovered a unique population of Hh-responsive cells in the developing murine enthesis that were distinct from tendon fibroblasts and epiphyseal chondrocytes. Lineage-tracing experiments revealed that the Gli1 lineage cells that originate in utero eventually populate the entire mature enthesis. Muscle paralysis increased the number of Hh-responsive cells in the enthesis, demonstrating that responsiveness to Hh is modulated in part by muscle loading. Ablation of the Hh-responsive cells during the first week of postnatal development resulted in a loss of mineralized fibrocartilage, with very little tissue remodeling 5 weeks after cell ablation. Conditional deletion of smoothened, a molecule necessary for responsiveness to Ihh, from the developing tendon and enthesis altered the differentiation of enthesis progenitor cells, resulting in significantly reduced fibrocartilage mineralization and decreased biomechanical function. Taken together, these results demonstrate that Hh signaling within developing enthesis fibrocartilage cells is required for enthesis formation. © 2015. Published by The Company of Biologists Ltd.

  10. Enthesis fibrocartilage cells originate from a population of Hedgehog-responsive cells modulated by the loading environment

    PubMed Central

    Schwartz, Andrea G.; Long, Fanxin; Thomopoulos, Stavros

    2015-01-01

    Tendon attaches to bone across a specialized tissue called the enthesis. This tissue modulates the transfer of muscle forces between two materials, i.e. tendon and bone, with vastly different mechanical properties. The enthesis for many tendons consists of a mineralized graded fibrocartilage that develops postnatally, concurrent with epiphyseal mineralization. Although it is well described that the mineralization and development of functional maturity requires muscle loading, the biological factors that modulate enthesis development are poorly understood. By genetically demarcating cells expressing Gli1 in response to Hedgehog (Hh) signaling, we discovered a unique population of Hh-responsive cells in the developing murine enthesis that were distinct from tendon fibroblasts and epiphyseal chondrocytes. Lineage-tracing experiments revealed that the Gli1 lineage cells that originate in utero eventually populate the entire mature enthesis. Muscle paralysis increased the number of Hh-responsive cells in the enthesis, demonstrating that responsiveness to Hh is modulated in part by muscle loading. Ablation of the Hh-responsive cells during the first week of postnatal development resulted in a loss of mineralized fibrocartilage, with very little tissue remodeling 5 weeks after cell ablation. Conditional deletion of smoothened, a molecule necessary for responsiveness to Ihh, from the developing tendon and enthesis altered the differentiation of enthesis progenitor cells, resulting in significantly reduced fibrocartilage mineralization and decreased biomechanical function. Taken together, these results demonstrate that Hh signaling within developing enthesis fibrocartilage cells is required for enthesis formation. PMID:25516975

  11. The failure mode of two reabsorbable fixation systems: Swivelock with Fibertape versus Bio-Corkscrew with Fiberwire in bovine rotator cuff.

    PubMed

    De Carli, Angelo; Lanzetti, Riccardo Maria; Monaco, Edoardo; Labianca, Luca; Mossa, Luigi; Ferretti, Andrea; Feretti, Andrea

    2012-11-01

    Despite technical advances in rotator cuff surgery, recurrent or persistent defects in the repaired tendon continue to occur. The improved strength of sutures and suture anchors has shown that the most common site of failure is the suture-tendon interface. The purpose of this study was to compare two different types of repair under both cyclic and load-to-failure conditions. The hypothesis is that the use of a fixation system with knotless anchor and taped suture results in better biomechanical performance, under both cyclic and load-to-failure conditions. Thirty bovine shoulder specimens were randomly assigned to two group tests: the Swivelock 5-mm anchor with Fibertape (Group A) and the Bio-Corkscrew 5 mm with Fiberwire (Group B). We simulated the reconstruction of a rotator cuff tear with a single-row technique, performing a tenodesis with types A and B fixation. Each specimen underwent cyclic testing from 5 to 30 N for 30 cycles, followed by load-to-failure testing, in order to calculate the ultimate failure load (UFL). Load-to-failure tests revealed a significantly higher UFL in Group A than in Group B. Wire fixing failed at the anchor loop whereas tape fixing failed at the sutures, suture-tendon interface, and anchors. Cyclic testing revealed no significantly greater slippage between the two groups. Stiffness values were not statistically significantly different. In all cases, tendons remained intact until the end of the cyclic testing. The tape structure is biomechanically stronger than the wire structure.

  12. Gluteal Tendinopathy: A Review of Mechanisms, Assessment and Management.

    PubMed

    Grimaldi, Alison; Mellor, Rebecca; Hodges, Paul; Bennell, Kim; Wajswelner, Henry; Vicenzino, Bill

    2015-08-01

    Tendinopathy of the gluteus medius and gluteus minimus tendons is now recognized as a primary local source of lateral hip pain. The condition mostly occurs in mid-life both in athletes and in subjects who do not regularly exercise. Females are afflicted more than males. This condition interferes with sleep (side lying) and common weight-bearing tasks, which makes it a debilitating musculoskeletal condition with a significant impact. Mechanical loading drives the biological processes within a tendon and determines its structural form and load-bearing capacity. The combination of excessive compression and high tensile loads within tendons are thought to be most damaging. The available evidence suggests that joint position (particularly excessive hip adduction), together with muscle and bone elements, are key factors in gluteal tendinopathy. These factors provide a basis for a clinical reasoning process in the assessment and management of a patient presenting with localized lateral hip pain from gluteal tendinopathy. Currently, there is a lack of consensus as to which clinical examination tests provide best diagnostic utility. On the basis of the few diagnostic utility studies and the current understanding of the pathomechanics of gluteal tendinopathy, we propose that a battery of clinical tests utilizing a combination of provocative compressive and tensile loads is currently best practice in its assessment. Management of this condition commonly involves corticosteroid injection, exercise or shock wave therapy, with surgery reserved for recalcitrant cases. There is a dearth of evidence for any treatments, so the approach we recommend involves managing the load on the tendons through exercise and education on the underlying pathomechanics.

  13. Quantitative analysis of the patella following the harvest of a quadriceps tendon autograft with a bone block.

    PubMed

    Ferrer, Gerald A; Miller, R Matthew; Murawski, Christopher D; Tashman, Scott; Irrgang, James J; Musahl, Volker; Fu, Freddie H; Debski, Richard E

    2016-09-01

    The objective of this study was to determine parameters associated with patellar fracture after quadriceps tendon autograft harvest. Thirteen non-fractured and five fractured patella surface models were created based on patient data obtained from a prospective randomized clinical trial in order to assess geometric parameters and bending stress. Measurements that describe the bone block harvest site geometry were used to calculate three normalized parameters. The relative depth parameter describes the thickness of the bone block harvest site with respect to the thickness of the patella at the harvest site. The asymmetry parameter defines the medial-lateral location of the bone bock harvest site. The normalized bending stress parameter assesses the bending stress experienced by the remaining bone beneath the bone block harvest site. The relative depth of the bone block harvest site in the non-fractured patellae was 27 ± 12 % and for the fractured patellae was 42 ± 14 % (p < 0.05). With a value <1 indicating a more lateral location of the harvest site, asymmetry for the non-fractured group was 1.0 ± 0.5 and 0.7 ± 0.4 for the fractured group (n.s.). The maximum bending stress experienced by the non-fractured patellae was (1.8 × 10(-3) ± 1.3 × 10(-3)) mm(-3) × M and for the fractured patellae was over three times greater (6.3 × 10(-3) ± 3.7 × 10(-3)) mm(-3) × M (p < 0.05). Based on the non-uniform geometry of the patella, an emphasis should be made on harvesting a standard percentage of patella thickness rather than a fixed depth. In order to minimize the incidence of a patellar fracture, bone blocks should not be taken laterally and should not exceed 30 % of the total patella thickness at the harvest site.

  14. How Obesity Affects Tendons?

    PubMed

    Abate, Michele; Salini, Vincenzo; Andia, Isabel

    Several epidemiological and clinical observations have definitely demonstrated that obesity has harmful effects on tendons. The pathogenesis of tendon damage is multi-factorial. In addition to overload, attributable to the increased body weight, which significantly affects load-bearing tendons, systemic factors play a relevant role. Several bioactive peptides (chemerin, leptin, adiponectin and others) are released by adipocytes, and influence tendon structure by means of negative activities on mesenchymal cells. The ensuing systemic state of chronic, sub-clinic, low-grade inflammation can damage tendon structure. Metabolic disorders (diabetes, impaired glucose tolerance, and dislipidemia), frequently associated with visceral adiposity, are concurrent pathogenetic factors. Indeed, high glucose levels increase the formation of Advanced Glycation End-products, which in turn form stable covalent cross-links within collagen fibers, modifying their structure and functionality.Sport activities, so useful for preventing important cardiovascular complications, may be detrimental for tendons if they are submitted to intense acute or chronic overload. Therefore, two caution rules are mandatory: first, to engage in personalized soft training program, and secondly to follow regular check-up for tendon pathology.

  15. A novel method for reducing gap formation in tendon repair.

    PubMed

    Dean, Ryan; Sethi, Paul

    2018-03-01

    This study investigates gap formation in tendon repair using a novel tensioning method. The novel stitch will demonstrate less gap formation than the other suture configurations tested. Porcine tendons stitched with classic Krackow stitch configurations were compared to a Krackow stitch modified with a proximal Tension-Assist Loop. Each group was cyclically loaded followed by analysis of the tendon-suture construct for gap formation. The Tension-Assist Loop group produced significantly less gap formation than each of the other stitch groups. Decreasing early gap formation may be beneficial in allowing early rehabilitation and range of motion.

  16. Physiological Tendon Thickness Adaptation in Adolescent Elite Athletes: A Longitudinal Study

    PubMed Central

    Cassel, Michael; Intziegianni, Konstantina; Risch, Lucie; Müller, Steffen; Engel, Tilman; Mayer, Frank

    2017-01-01

    Increased Achilles (AT) and Patellar tendon (PT) thickness in adolescent athletes compared to non-athletes could be shown. However, it is unclear, if changes are of pathological or physiological origin due to training. The aim of this study was to determine physiological AT and PT thickness adaptation in adolescent elite athletes compared to non-athletes, considering sex and sport. In a longitudinal study design with two measurement days (M1/M2) within an interval of 3.2 ± 0.8 years, 131 healthy adolescent elite athletes (m/f: 90/41) out of 13 different sports and 24 recreationally active controls (m/f: 6/18) were included. Both ATs and PTs were measured at standardized reference points. Athletes were divided into 4 sport categories [ball (B), combat (C), endurance (E) and explosive strength sports (S)]. Descriptive analysis (mean ± SD) and statistical testing for group differences was performed (α = 0.05). AT thickness did not differ significantly between measurement days, neither in athletes (5.6 ± 0.7 mm/5.6 ± 0.7 mm) nor in controls (4.8 ± 0.4 mm/4.9 ± 0.5 mm, p > 0.05). For PTs, athletes presented increased thickness at M2 (M1: 3.5 ± 0.5 mm, M2: 3.8 ± 0.5 mm, p < 0.001). In general, males had thicker ATs and PTs than females (p < 0.05). Considering sex and sports, only male athletes from B, C, and S showed significant higher PT-thickness at M2 compared to controls (p ≤ 0.01). Sport-specific adaptation regarding tendon thickness in adolescent elite athletes can be detected in PTs among male athletes participating in certain sports with high repetitive jumping and strength components. Sonographic microstructural analysis might provide an enhanced insight into tendon material properties enabling the differentiation of sex and influence of different sports. PMID:29075203

  17. Distal Attachment of Flexor Tendon Allograft: A Biomechanical Study of Different Reconstruction Techniques in Human Cadaver Hands

    PubMed Central

    Wei, Zhuang; Thoreson, Andrew R.; Amadio, Peter C.; An, Kai-Nan; Zhao, Chunfeng

    2014-01-01

    We compared the mechanical force of tendon-to-bone repair techniques for flexor tendon reconstruction. Thirty-six flexor digitorum profundus (FDP) tendons were divided into three groups based upon the repair technique: (1) suture/button repair using FDP tendon (Pullout button group), (2) suture bony anchor using FDP tendon (Suture anchor group), and (3) suture/button repair using FDP tendon with its bony attachment preserved (Bony attachment group). The repair failure force and stiffness were measured. The mean load to failure and stiffness in the bony attachment group were significantly higher than that in the pullout button and suture anchor groups. No significant difference was found in failure force and stiffness between the pullout button and suture anchor groups. An intrasynovial flexor tendon graft with its bony attachment has significantly improved tensile properties at the distal repair site when compared with a typical tendon-to-bone attachment with a button or suture anchor. The improvement in the tensile properties at the repair site may facilitate postoperative rehabilitation and reduce the risk of graft rupture. PMID:23754507

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harper, J.; Amiel, D.; Harper, E.

    The authors examined the patellar tendon (PT), anterior cruciate ligament (ACL) and medial collateral ligament (MCL) from normal rabbits for collagenase activity. All three connective tissues contain large amounts of collagen and the catabolism of this structural protein is important to their integrity. The authors cultured each tissue in serum free medium for 14 days. Collagenase was produced by all three connective tissues after a lag period of up to 7 days, as detected by the /sup 14/C-glycine peptide-release assay. Culture media that did not express enzyme the authors found to contain inhibitory activity. The collagenases and inhibitors from eachmore » tissue have been quantitated and characterized. After 9 days the collagenase activity for the rabbit periarticular tissues was 6.1 (PT), 4.4 (MCL) and 8.6 (ACL) units per milligram of secreted protein. The cleavage site of all three collagenases was found to be similar to that observed for rabbit skin collagenase, and generation of reaction products TC/sup A/ and TC/sup B/ was demonstrated by collagenases from PT, MCL and ACL. These results suggest that the metabolism of ligaments and tendon is regulated by the production of zymogen, active collagenase and inhibitor, similar to other connective tissues. The role of these components in joint injury and joint diseases is currently being investigated.« less

  19. Interventional articular and para-articular knee procedures

    PubMed Central

    Lalam, Radhesh K; Winn, Naomi

    2016-01-01

    The knee is a common area of the body to undergo interventional procedures. This article discusses image-guided interventional issues specific to the knee area. The soft tissues in and around the knee are frequently affected by sport-related injuries and often need image-guided intervention. This article details the specific technical issues related to intervention in these soft tissues, including the iliotibial tract, fat pads, patellar tendon and other tendons, bursae and the meniscus. Most often, simple procedures such as injection and aspiration are performed without image guidance. Rarely image-guided diagnostic arthrography and therapeutic joint injections are necessary. The technique, indications and diagnostic considerations for arthrography are discussed in this article. Primary bone and soft-tissue tumours may involve the knee and adjacent soft tissues. Image-guided biopsies are frequently necessary for these lesions; this article details the technical issues related to image-guided biopsy around the knee. A number of newer ablation treatments are now available, including cryoablation, high-frequency ultrasound and microwave ablation. Radiofrequency ablation, however, still remains the most commonly employed ablation technique. The indications, technical and therapeutic considerations related to the application of this technique around the knee are discussed here. Finally, we briefly discuss some newer, but as of yet, unproven image-guided interventions for osteochondral lesions and Brodie's abscess. PMID:26682669

  20. Neuropeptides in tendinopathy

    PubMed Central

    Scott, Alexander; Bahr, Roald

    2014-01-01

    Tendinopathy is a clinical syndrome of pain, tendon thickening, and increased blood flow. The current review highlights evidence supporting an underlying role of neuropeptides in the etiology, clinical presentation, and treatment of painful overuse tendinopathy. Painful tendons demonstrate an increased presence of Substance P-containing nerves which are strongly implicated as a potential source of pain, but which also play important roles in the tendon’s attempt to self-repair. Recent findings have identified potential roles of additional sensory and autonomic neuropeptides which regulate pain, tissue remodeling, and vascular flow, including acetylcholine, noradrenaline and neuropeptide Y. Neuropeptide production within tendons is stimulated by mechanical load and exercise, and both direct and indirect neuropeptide effects may be responsible for the potential benefits of heavy-load eccentric loading. A model is presented which delineates the physiologic basis for signalling pathways between tenocytes, mast cells and sensory and autonomic nerves, with implications for understanding the mechanisms of traditional as well as emerging treatment strategies including sclerosing therapy and nitric oxide. PMID:19273194

  1. Incidence of Major Tendon Ruptures and Anterior Cruciate Ligament Tears in US Army Soldiers

    DTIC Science & Technology

    2007-08-01

    the effect of activity, race, age, or gender. The majority of the reports have been case studies or focused on one particular tendon and do not have...forces created by eccentric muscle activation are usually responsible for tendon failure. 1312 White et al The American Journal of Sports Medicine...Activities that maximize eccentric loading, such as repeti- tive jumping and sprinting exercises for the lower extrem- ities (bench press for the pectoralis

  2. Tendon-to-bone attachment: from development to maturity.

    PubMed

    Zelzer, Elazar; Blitz, Einat; Killian, Megan L; Thomopoulos, Stavros

    2014-03-01

    The attachment between tendon and bone occurs across a complex transitional tissue that minimizes stress concentrations and allows for load transfer between muscles and skeleton. This unique tissue cannot be reconstructed following injury, leading to high incidence of recurrent failure and stressing the need for new clinical approaches. This review describes the current understanding of the development and function of the attachment site between tendon and bone. The embryonic attachment unit, namely, the tip of the tendon and the bone eminence into which it is inserted, was recently shown to develop modularly from a unique population of Sox9- and Scx-positive cells, which are distinct from tendon fibroblasts and chondrocytes. The fate and differentiation of these cells is regulated by transforming growth factor beta and bone morphogenetic protein signaling, respectively. Muscle loads are then necessary for the tissue to mature and mineralize. Mineralization of the attachment unit, which occurs postnatally at most sites, is largely controlled by an Indian hedgehog/parathyroid hormone-related protein feedback loop. A number of fundamental questions regarding the development of this remarkable attachment system require further study. These relate to the signaling mechanism that facilitates the formation of an interface with a gradient of cellular and extracellular phenotypes, as well as to the interactions between tendon and bone at the point of attachment. Copyright © 2014 Wiley Periodicals, Inc.

  3. Tensile properties of a morphologically split supraspinatus tendon.

    PubMed

    Matsuhashi, Tomoya; Hooke, Alexander W; Zhao, Kristin D; Goto, Akira; Sperling, John W; Steinmann, Scott P; An, Kai-Nan

    2014-07-01

    The supraspinatus tendon consists morphologically of two sub-regions, anterior and posterior. The anterior sub-region is thick and tubular while the posterior is thin and strap-like. The purpose of this study was to compare the structural and mechanical properties of the anterior and posterior sub-regions of the supraspinatus tendon. The supraspinatus tendons from seven human cadaveric shoulders were morphologically divided into the anterior and posterior sub-regions. Length, width, and thickness were measured. A servo-hydraulic testing machine (MTS Systems Corporation, Minneapolis, MN) was used for tensile testing. The maximal load at failure, modulus of elasticity and ultimate tendon stress were calculated. Repeated measures were used for statistical comparisons. The mean anterior tendon cross-sectional area was 47.3 mm(2) and the posterior was 32.1 mm(2) . Failure occurred most often at the insertion site: anterior (5/7) and posterior (6/7). All parameters of the anterior sub-region were significantly greater than those of the posterior sub-region. The moduli of elasticity at the insertion site were 592.4 MPa in the anterior sub-region and 217.7 MPa in the posterior (P = 0.01). The ultimate failure loads were 779.2 N in the anterior sub-region and 335.6 N in the posterior (P = 0.003). The ultimate stresses were 22.1 MPa in the anterior sub-region and 11.6 MPa in the posterior (P = 0.008). We recognized that the anterior and posterior sub-regions of the SSP tendon have significantly different mechanical properties. In a future study, we need to evaluate how best to repair an SSP tendon considering these region-specific properties. Copyright © 2013 Wiley Periodicals, Inc.

  4. Achilles Tendon Properties of Minimalist and Traditionally Shod Runners.

    PubMed

    Histen, Katherine; Arntsen, Julia; L'Hereux, Lauren; Heeren, James; Wicki, Benjamin; Saint, Sterling; Aerni, Giselle; Denegar, Craig R; Joseph, Michael F

    2017-04-01

    Tendon adapts to load through alterations in its composition and mechanical properties. Mechanical adaptation to increased load often involves increases in cross-sectional area (CSA), stiffness, and modulus. Runners exhibit these adaptations. To determine if runners wearing minimalist shoes had larger and stiffer Achilles tendons (AT) than traditionally shod runners. Cross-sectional study of well-trained, traditionally and minimally shod runners. Laboratory assessment of trained runners. 23 men (11 traditional, 12 minimalist) and 8 women (6 traditional, 2 minimalist). Runners wearing minimalist shoes had 4.2 ± 1.6 y of training experience in minimalist shoes. The authors used diagnostic ultrasound and isokinetic dynamometry to generate a force-elongation curve and its derivatives. Minimalist runners had a greater CSA: mean difference (MD) = 9.2 mm 2 , stiffness (MD = 268.1 N/mm), and modulus (MD = 202.9 MPa). ATs of minimalist runners experienced greater stress (MD 8.6 N/mm 2 ) during maximal voluntary isometric contraction of the plantar-flexor muscles due to greater force of contraction (MD 798.9 N). The AT in minimalist runners adapts by increasing size, stiffness, and modulus, which is consistent with our understanding of mechanical adaptation of tendon to increased loading. Increased stress to the AT likely requires a slow transition to minimalist running to allow the AT to adapt without evidence of injury.

  5. Tensile properties of craniofacial tendons in the mature and aged zebrafish

    PubMed Central

    Shah, Rishita R.; Nerurkar, Nandan L.; Wang, Calvin; Galloway, Jenna L.

    2015-01-01

    The zebrafish Danio rerio is a powerful model for the study of development, regenerative biology, and human disease. However, the analysis of load-bearing tissues such as tendons and ligaments has been limited in this system. This is largely due to technical limitations that preclude accurate measurement of their mechanical properties. Here, we present a custom tensile testing system that applies nano-Newton scale forces to zebrafish tendons as small as 1 mm in length. Tendon properties were remarkably similar to mammalian tendons, including stress-strain nonlinearity and a linear modulus (515±152 MPa) that aligned closely with mammalian data. Additionally, a simple exponential constitutive law used to describe tendon mechanics was successfully fit to zebrafish tendons; the associated material constants agreed with literature values for mammalian tendons. Finally, mature and aged zebrafish comparisons revealed a significant decline in mechanical function with age. Based on the exponential constitutive model, age related changes were primarily caused by a reduction in nonlinearity (e.g. changes in collagen crimp or fiber recruitment). These findings demonstrate the utility of zebrafish as a model to study tendon biomechanics in health and disease. Moreover, these findings suggest that tendon mechanical behavior is highly conserved across vertebrates. PMID:25665155

  6. Biomechanical validation of load-sharing rip-stop fixation for the repair of tissue-deficient rotator cuff tears.

    PubMed

    Burkhart, Stephen S; Denard, Patrick J; Konicek, John; Hanypsiak, Bryan T

    2014-02-01

    Poor-quality tendon is one of the most difficult problems the surgeon must overcome in achieving secure fixation during rotator cuff repair. A load-sharing rip-stop construct (LSRS) has recently been proposed as a method for improving fixation strength, but the biomechanical properties of this construct have not yet been examined. To compare the strength of the LSRS construct to that of single-row fixation for rotator cuff repair. Controlled laboratory study. Rotator cuff tears were created in 6 cadaveric matched-pair specimens and repaired with a single row or an LSRS. In the LSRS repair, a 2-mm suture tape was placed as an inverted mattress stitch in the rotator cuff, and sutures from 2 anchors were placed as simple stitches that passed medial to the suture tape. The suture tape limbs were secured with knotless anchors laterally before sutures were tied from the medial anchors. Displacement was observed with video tracking after cyclic loading, and specimens were loaded to failure. The mean load to failure was 371 ± 102 N in single-row repairs compared with 616 ± 185 N in LSRS repairs (P = .031). There was no difference in displacement with cyclic loading between the groups (3.3 ± 0.8 mm vs. 3.5 ± 1.1 mm; P = .561). In the single-row group, 4 of 6 failures occurred at the suture-tendon interface. In the LSRS group, only 1 failure occurred at the suture-tendon interface. The ultimate failure load of the LSRS construct for rotator cuff repair was 1.7 times that of a single-row construct in a cadaveric model. The LSRS rotator cuff repair construct may be useful in the repair of difficult tears such as massive tears, medial tears, and tears with tendon loss.

  7. Quantitative ultrasound method for assessing stress-strain properties and the cross-sectional area of Achilles tendon

    NASA Astrophysics Data System (ADS)

    Du, Yi-Chun; Chen, Yung-Fu; Li, Chien-Ming; Lin, Chia-Hung; Yang, Chia-En; Wu, Jian-Xing; Chen, Tainsong

    2013-12-01

    The Achilles tendon is one of the most commonly observed tendons injured with a variety of causes, such as trauma, overuse and degeneration, in the human body. Rupture and tendinosis are relatively common for this strong tendon. Stress-strain properties and shape change are important biomechanical properties of the tendon to assess surgical repair or healing progress. Currently, there are rather limited non-invasive methods available for precisely quantifying the in vivo biomechanical properties of the tendons. The aim of this study was to apply quantitative ultrasound (QUS) methods, including ultrasonic attenuation and speed of sound (SOS), to investigate porcine tendons in different stress-strain conditions. In order to find a reliable method to evaluate the change of tendon shape, ultrasound measurement was also utilized for measuring tendon thickness and compared with the change in tendon cross-sectional area under different stress. A total of 15 porcine tendons of hind trotters were examined. The test results show that the attenuation and broadband ultrasound attenuation decreased and the SOS increased by a smaller magnitude as the uniaxial loading of the stress-strain upon tendons increased. Furthermore, the tendon thickness measured with the ultrasound method was significantly correlated with tendon cross-sectional area (Pearson coefficient = 0.86). These results also indicate that attenuation of QUS and ultrasonic thickness measurement are reliable and potential parameters for assessing biomechanical properties of tendons. Further investigations are needed to warrant the application of the proposed method in a clinical setting.

  8. Non-linear finite element model to assess the effect of tendon forces on the foot-ankle complex.

    PubMed

    Morales-Orcajo, Enrique; Souza, Thales R; Bayod, Javier; Barbosa de Las Casas, Estevam

    2017-11-01

    A three-dimensional foot finite element model with actual geometry and non-linear behavior of tendons is presented. The model is intended for analysis of the lower limb tendon forces effect in the inner foot structure. The geometry of the model was obtained from computational tomographies and magnetic resonance images. Tendon tissue was characterized with the first order Ogden material model based on experimental data from human foot tendons. Kinetic data was employed to set the load conditions. After model validation, a force sensitivity study of the five major foot extrinsic tendons was conducted to evaluate the function of each tendon. A synergic work of the inversion-eversion tendons was predicted. Pulling from a peroneus or tibialis tendon stressed the antagonist tendons while reducing the stress in the agonist. Similar paired action was predicted for the Achilles tendon with the tibialis anterior. This behavior explains the complex control motion performed by the foot. Furthermore, the stress state at the plantar fascia, the talocrural joint cartilage, the plantar soft tissue and the tendons were estimated in the early and late midstance phase of walking. These estimations will help in the understanding of the functional role of the extrinsic muscle-tendon-units in foot pronation-supination. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  9. Contribution of actin filaments to the global compressive properties of fibroblasts.

    PubMed

    Ujihara, Yoshihiro; Nakamura, Masanori; Miyazaki, Hiroshi; Wada, Shigeo

    2012-10-01

    Actin filaments are often regarded as tension-bearing components. Here, we examined the effects of actin filaments on global compressive properties of cells experimentally and numerically. Fibroblasts were harvested from the patellar tendon of a mature Japanese white rabbit and treated with cytochalasin D to depolymerize the actin filaments. Intact cells and cells with disrupted actin filaments were subjected to the compressive tests. Each floating cell was held between the cantilever and compressive plates and compressed by moving the compressive plate with a linear actuator to obtain a load-deformation curve under quasi-static conditions. The experimental results demonstrated that the initial stiffness of a cell with disrupted actin filaments decreased by 51%. After the experiments, we simulated the compressive test of cells with/without bundles of actin filaments. A bundle of actin filaments was modeled as a tension-bearing component that generates a force based on Hooke's law only when it was elongated. By contrast, if it was shortened, it was assumed to exert no force. The computational results revealed that the alignment of bundles of actin filaments significantly affected the cell stiffness. In addition, the passive reorientation of bundles of actin filaments perpendicular to the compression induced an increase in the resistance to the vertical elongation of a cell and thereby increased the cell stiffness. These results clearly indicated that bundles of actin filaments contribute to the compressive properties of a cell, even if they are tension-bearing components. Copyright © 2012 Elsevier Ltd. All rights reserved.

  10. Biomechanical Performance of Medial Row Suture Placement Relative to the Musculotendinous Junction in Transosseous Equivalent Suture Bridge Double-Row Rotator Cuff Repair.

    PubMed

    Virk, Mandeep S; Bruce, Benjamin; Hussey, Kristen E; Thomas, Jacqueline M; Luthringer, Tyler A; Shewman, Elizabeth F; Wang, Vincent M; Verma, Nikhil N; Romeo, Anthony A; Cole, Brian J

    2017-02-01

    To compare the biomechanical performance of medial row suture placement relative to the musculotendinous junction (MTJ) in a cadaveric transosseous equivalent suture bridge (TOE-SB) double-row (DR) rotator cuff repair (RCR) model. A TOE-SB DR technique was used to reattach experimentally created supraspinatus tendon tears in 9 pairs of human cadaveric shoulders. The medial row sutures were passed either near the MTJ (MTJ group) or 10 mm lateral to the MTJ (rotator cuff tendon [RCT] group). After the supraspinatus repair, the specimens underwent cyclic loading and load to failure tests. The localized displacement of the markers affixed to the tendon surface was measured with an optical tracking system. The MTJ group showed a significantly higher (P = .03) medial row failure (5/9; 3 during cyclic testing and 2 during load to failure testing) compared with the RCT group (0/9). The mean number of cycles completed during cyclic testing was lower in the MTJ group (77) compared with the RCT group (100; P = .07) because 3 specimens failed in the MTJ group during cyclic loading. There were no significant differences between the 2 study groups with respect to biomechanical properties during the load to failure testing. In a cadaveric TOE-SB DR RCR model, medial row sutures through the MTJ results in a significantly higher rate of medial row failure. In rotator cuff tears with tendon tissue loss, passage of medial row sutures through the MTJ should be avoided in a TOE-SB RCR technique because of the risk of medial row failure. Copyright © 2016. Published by Elsevier Inc.

  11. Effects of running on human Achilles tendon length-tension properties in the free and gastrocnemius components.

    PubMed

    Lichtwark, Glen A; Cresswell, Andrew G; Newsham-West, Richard J

    2013-12-01

    The elastic properties of the human Achilles tendon are important for locomotion; however, in vitro tests suggest that repeated cyclic contractions lead to tendon fatigue - an increase in length in response to stress applied. In vivo experiments have not, however, demonstrated mechanical fatigue in the Achilles tendon, possibly due to the limitations of using two-dimensional ultrasound imaging to assess tendon strain. This study used freehand three-dimensional ultrasound (3DUS) to determine whether the free Achilles tendon (calcaneus to soleus) or the gastrocnemius tendon (calcaneus to gastrocnemius) demonstrated tendon fatigue after running exercise. Participants (N=9) underwent 3DUS scans of the Achilles tendon during isometric contractions at four ankle torque levels (passive, and 14, 42 and 70 N m) before and after a 5 km run at a self-selected pace (10-14 km h(-1)). Running had a significant main effect on the length of the free Achilles tendon (P<0.01) with a small increase in length across the torque range. However, the mean lengthening effect was small (<1%) and was not accompanied by a change in free tendon stiffness. There was no significant change in the length of the gastrocnemius tendon or the free tendon cross-sectional area. While the free tendon was shown to lengthen, the lack of change in stiffness suggests the tendon exhibited mechanical creep rather than fatigue. These effects were much smaller than those predicted from in vitro experiments, possibly due to the different loading profile encountered and the ability of the tendon to repair in vivo.

  12. Tendon-Holding Capacities of Two Newly Designed Implants for Tendon Repair: An Experimental Study on the Flexor Digitorum Profundus Tendon of Sheep

    PubMed Central

    Ağır, İsmail; Aytekin, Mahmut Nedim; Başçı, Onur; Çaypınar, Barış; Erol, Bülent

    2014-01-01

    Background: Two main factors determine the strength of tendon repair; the tensile strength of material and the gripping capacity of a suture configuration. Different repair techniques and suture materials were developed to increase the strength of repairs but none of techniques and suture materials seem to provide enough tensile strength with safety margins for early active mobilization. In order to overcome this problem tendon suturing implants are being developed. We designed two different suturing implants. The aim of this study was to measure tendon-holding capacities of these implants biomechanically and to compare them with frequently used suture techniques Materials and Methods: In this study we used 64 sheep flexor digitorum profundus tendons. Four study groups were formed and each group had 16 tendons. We applied model 1 and model 2 implant to the first 2 groups and Bunnell and locking-loop techniques to the 3rd and 4th groups respectively by using 5 Ticron sutures. Results: In 13 tendons in group 1 and 15 tendons in group 2 and in all tendons in group 3 and 4, implants and sutures pulled out of the tendon in longitudinal axis at the point of maximum load. The mean tensile strengths were the largest in group 1 and smallest in group 3. Conclusion: In conclusion, the new stainless steel tendon suturing implants applied from outside the tendons using steel wires enable a biomechanically stronger repair with less tendon trauma when compared to previously developed tendon repair implants and the traditional suturing techniques. PMID:25067965

  13. Repair of Double Head Pectoralis Major Tendon Avulsion into its Native Footprint Using Bi-cortical EndoButtons and Tendon Sliding Technique.

    PubMed

    Prabhu, Jagadish; Faqi, Mohammed Khalid; Alkhalifa, Fahad; Tayara, Bader Kamal; Awad, Rashad Khamis

    2017-01-01

    Injuries to the pectoralis major muscle are relatively infrequent. The mechanism of injury is usually an eccentric shortening of the pectoralis major under heavy load, such as when performing a bench press exercise. We report a case that presented to us with a history of sudden pain in the left pectoral region while doing heavy bench press exercise. The patient sustained a type III D pectoralis muscle -tendon avulsion. Surgical repair was done through a bi-cortical tendon sliding technique using two cortical buttons. In this article we describe our modifications to the previously described surgical technique for the pectoralis major tendon repair using the EndoButton and tension - slide technique, aiming to overcome the possible complications.

  14. Healing of rotator cuff tendons using botulinum toxin A and immobilization in a rat model.

    PubMed

    Gilotra, Mohit N; Shorofsky, Michael J; Stein, Jason A; Murthi, Anand M

    2016-03-15

    We evaluated effects of botulinum toxin A (Botox) and cast immobilization on tendon healing in a rat model. Injection of Botox into rat supraspinatus was hypothesized to reduce muscle active force and improved healing. Eighty-four supraspinatus tendons were surgically transected and repaired in 42 Sprague-Dawley rats (transosseous technique). After repair, supraspinatus muscle was injected with saline or Botox (3 or 6 U/kg). Half the shoulders were cast-immobilized for the entire postoperative period; half were allowed free cage activity. Histology was examined at 2, 4, 8, and 12 weeks. A healing zone cross-sectional area was measured, and biomechanical testing of repair strength and tendon viscoelastic properties was conducted at 4 and 12 weeks. Botox alone and cast immobilization alone exhibited increased ultimate load compared with controls (saline injection, no immobilization) at 4 weeks. No difference in ultimate load occurred between Botox-only and cast-only groups. At 12 weeks, the Botox (6 U/kg) plus cast immobilization group was significantly weakest (p < 0.05). A trend was shown toward decreased healing zone cross-sectional areas in casted groups. Supraspinatus Botox injection after rotator cuff repair might help protect the repair. However, cast immobilization plus Botox administration is harmful to rotator cuff healing in a rat tendon model.

  15. Definition and Reliability Assessment of Elementary Ultrasonographic Findings in Calcium Pyrophosphate Deposition Disease: A Study by the OMERACT Calcium Pyrophosphate Deposition Disease Ultrasound Subtask Force.

    PubMed

    Filippou, Georgios; Scirè, Carlo A; Damjanov, Nemanja; Adinolfi, Antonella; Carrara, Greta; Picerno, Valentina; Toscano, Carmela; Bruyn, George A; D'Agostino, Maria Antonietta; Delle Sedie, Andrea; Filippucci, Emilio; Gutierrez, Marwin; Micu, Mihaela; Möller, Ingrid; Naredo, Esperanza; Pineda, Carlos; Porta, Francesco; Schmidt, Wolfgang A; Terslev, Lene; Vlad, Violeta; Zufferey, Pascal; Iagnocco, Annamaria

    2017-11-01

    To define the ultrasonographic characteristics of calcium pyrophosphate crystal (CPP) deposits in joints and periarticular tissues and to evaluate the intra- and interobserver reliability of expert ultrasonographers in the assessment of CPP deposition disease (CPPD) according to the new definitions. After a systematic literature review, a Delphi survey was circulated among a group of expert ultrasonographers, who were members of the CPPD Ultrasound (US) Outcome Measures in Rheumatology (OMERACT) subtask force, to obtain definitions of the US characteristics of CPPD at the level of fibrocartilage (FC), hyaline cartilage (HC), tendon, and synovial fluid (SF). Subsequently, the reliability of US in assessing CPPD at knee and wrist levels according to the agreed definitions was tested in static images and in patients with CPPD. Cohen's κ was used for statistical analysis. HC and FC of the knee yielded the highest interobserver κ values among all the structures examined, in both the Web-based (0.73 for HC and 0.58 for FC) and patient-based exercises (0.55 for the HC and 0.64 for the FC). Kappa values for the other structures were lower, ranging from 0.28 in tendons to 0.50 in SF in the static exercise and from 0.09 (proximal patellar tendon) to 0.27 (triangular FC of the wrist) in the patient-based exercise. The new OMERACT definitions for the US identification of CPPD proved to be reliable at the level of the HC and FC of the knee. Further studies are needed to better define the US characteristics of CPPD and optimize the scanning technique in other anatomical sites.

  16. Preoperative cryotherapy use in anterior cruciate ligament reconstruction.

    PubMed

    Koyonos, Loukas; Owsley, Kevin; Vollmer, Emily; Limpisvasti, Orr; Gambardella, Ralph

    2014-12-01

    Unrelieved postoperative pain may impair rehabilitation, compromise functional outcomes, and lead to patient dissatisfaction. Preemptive multimodal analgesic techniques may improve outcomes after surgery. We hypothesized that patients using preoperative cryotherapy plus a standardized postoperative treatment plan will have lower pain scores and require less pain medication compared with patients receiving a standardized postoperative treatment plan alone after arthroscopically assisted anterior cruciate ligament reconstruction (ACLR). A total of 53 consecutive patients undergoing arthroscopically assisted ACLR performed by one of seven surgeons were randomly assigned to one of two groups. Group 1 received no preoperative cryotherapy and group 2 received 30 to 90 minutes of preoperative cryotherapy to the operative leg using a commercial noncompressive cryotherapy unit. Visual analog scale pain scores and narcotic use were recorded for the first 4 days postoperatively. Total hours of cold therapy and continuous passive motion (CPM) use and highest degree of flexion achieved were recorded as well. Group 1 consisted of 26 patients (15 allograft Achilles tendon and 11 autograft bone patellar tendon bone [BPTB]), and group 2 consisted of 27 patients (16 allograft Achilles tendon and 11 autograft BPTB). Group 2 patients reported less pain (average 1.3 units, p < 0.02) and used less narcotic use (average 1.7 tablets, p < 0.02) for the first 36 hours compared with group 1. No statistically significant differences were identified between the two groups with regard to demographics, hours of postoperative cryotherapy, hours of CPM use, or maximum knee flexion achieved. Complications did not occur in either group. This is the first report we are aware of showing the postoperative effects of preoperative cryotherapy. Our results support the safety and efficacy of preoperative cryotherapy in a multimodal pain regimen for patients undergoing ACL reconstruction. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  17. Conditioning of the Achilles tendon via ankle exercise improves correlations between sonographic measures of tendon thickness and body anthropometry.

    PubMed

    Wearing, Scott C; Grigg, Nicole L; Hooper, Sue L; Smeathers, James E

    2011-05-01

    Although conditioning is routinely used in mechanical tests of tendon in vitro, previous in vivo research evaluating the influence of body anthropometry on Achilles tendon thickness has not considered its potential effects on tendon structure. This study evaluated the relationship between Achilles tendon thickness and body anthropometry in healthy adults both before and after resistive ankle plantarflexion exercise. A convenience sample of 30 healthy male adults underwent sonographic examination of the Achilles tendon in addition to standard anthropometric measures of stature and body weight. A 10-5 MHz linear array transducer was used to acquire longitudinal sonograms of the Achilles tendon, 20 mm proximal to the tendon insertion. Participants then completed a series (90-100 repetitions) of conditioning exercises against an effective resistance between 100% and 150% body weight. Longitudinal sonograms were repeated immediately on completion of the exercise intervention, and anteroposterior Achilles tendon thickness was determined. Achilles tendon thickness was significantly reduced immediately following conditioning exercise (t = 9.71, P < 0.001), resulting in an average transverse strain of -18.8%. In contrast to preexercise measures, Achilles tendon thickness was significantly correlated with body weight (r = 0.72, P < 0.001) and to a lesser extent height (r = 0.45, P = 0.01) and body mass index (r = 0.63, P < 0.001) after exercise. Conditioning of the Achilles tendon via resistive ankle exercises induces alterations in tendon structure that substantially improve correlations between Achilles tendon thickness and body anthropometry. It is recommended that conditioning exercises, which standardize the load history of tendon, are employed before measurements of sonographic tendon thickness in vivo.

  18. Walking with springs

    NASA Astrophysics Data System (ADS)

    Sugar, Thomas G.; Hollander, Kevin W.; Hitt, Joseph K.

    2011-04-01

    Developing bionic ankles poses great challenges due to the large moment, power, and energy that are required at the ankle. Researchers have added springs in series with a motor to reduce the peak power and energy requirements of a robotic ankle. We developed a "robotic tendon" that reduces the peak power by altering the required motor speed. By changing the required speed, the spring acts as a "load variable transmission." If a simple motor/gearbox solution is used, one walking step would require 38.8J and a peak motor power of 257 W. Using an optimized robotic tendon, the energy required is 21.2 J and the peak motor power is reduced to 96.6 W. We show that adding a passive spring in parallel with the robotic tendon reduces peak loads but the power and energy increase. Adding a passive spring in series with the robotic tendon reduces the energy requirements. We have built a prosthetic ankle SPARKy, Spring Ankle with Regenerative Kinetics, that allows a user to walk forwards, backwards, ascend and descend stairs, walk up and down slopes as well as jog.

  19. Cyclic Testing of the 6-Strand Tang and Modified Lim-Tsai Flexor Tendon Repair Techniques.

    PubMed

    Kang, Gavrielle Hui-Ying; Wong, Yoke-Rung; Lim, Rebecca Qian-Ru; Loke, Austin Mun-Kitt; Tay, Shian-Chao

    2018-03-01

    In this study, we compared the Tang repair technique with the 6-strand modified Lim-Tsai repair technique under cyclic testing conditions. Twenty fresh-frozen porcine flexor tendons were randomized into 2 groups for repair with either the modified Lim-Tsai or the Tang technique using Supramid 4-0 core sutures and Ethilon 6-0 epitendinous running suture. The repaired tendons were subjected to 2 stage cyclic loading. The survival rate and gap formation at the repair site were recorded. Tendons repaired by the Tang technique achieved an 80% survival rate. None of the modified Lim-Tsai repairs survived. The mean gap formed at the end of 1000 cycles was 1.09 mm in the Tang repairs compared with 4.15 mm in the modified Lim-Tsai repairs. The Tang repair is biomechanically stronger than the modified Lim-Tsai repair under cyclic loading. The Tang repair technique may exhibit a higher tolerance for active mobilization after surgery with less propensity for gap formation. Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  20. Peri-anterior cruciate ligament reconstruction femur fracture: a biomechanical analysis of the femoral tunnel as a stress riser.

    PubMed

    Han, Yung; Sardar, Zeeshan; McGrail, Scott; Steffen, Thomas; Martineau, Paul A

    2011-12-01

    Sixteen case reports of distal femur fractures as post-operative complications after anterior cruciate ligament (ACL) reconstruction have been described in the literature. The femoral tunnel has been suggested as a potential stress riser for fracture formation. Additionally, double bundle ACL reconstructions may compound this risk. This is the first biomechanical study to examine the significance of a stress riser effect of the femoral tunnel(s) after ACL reconstruction. The hypotheses tested in this study are that the femoral tunnel acts as a stress riser for fracture and that this effect increases with the size of the tunnel (8 mm vs. 10 mm) and with the number of tunnels (1 vs. 2). Femoral tunnels simulating single bundle (SB) hamstring graft (8 mm), bone-patellar tendon-bone graft (10 mm), and double bundle (DB) ACL reconstruction (7, 6 mm) were drilled in fourth-generation saw bones. These three experimental groups and a control group consisting of native saw bones without tunnels were loaded to failure. All fractures occurred through the tunnels in the DB group, whereas fractures did not consistently occur through the tunnels in the SB groups. The mean fracture load was 6,145N ± 471N in the native group, 5,691N ± 198N in the 8 mm SB group, 5,702N ± 282N in the 10 mm SB group, and 4,744N ± 418N in the DB group. The mean fracture load for the DB group was significantly lower when compared to the native, 8 mm SB, and 10 mm SB groups independently (P value = 0.0016, 0.0060, and 0.0038, respectively). The mean fracture loads for neither SB groups were not significantly different from the native group. An anatomically placed femoral tunnel in single bundle ACL reconstruction in our experimental model was not a significant stress riser to fracture, whereas the two femoral tunnels in double bundle ACL reconstruction significantly decreased load to failure. The results support the sparsity of reported peri-ACL reconstruction femur fractures in single femoral tunnel techniques. However, the increased fracture risk in double bundle ACL reconstruction may be a cause for concern and impact patient selection.

  1. Enhanced biological properties of biomimetic apatite fabricated polycaprolactone/chitosan nanofibrous bio-composite for tendon and ligament regeneration.

    PubMed

    Wu, Geng; Deng, Xuefeng; Song, Jinqi; Chen, Feiqiang

    2018-01-01

    The development of tailored nanofibrous scaffolds for tendon and ligament tissue engineering has been a goal of clinical research for current researchers. Here, we establish a formation of novel nanofibrous matrix with significant mechanical and biological properties by electro-spinning process. The fine fibrous morphology of the nanostructured hydroxyapatite (HAp) dispersed in the polycaprolactone/chitosan (HAp-PCL/CS) nanofibrous matrix was exhibited by microscopic (SEM and TEM) techniques. The favorable mechanical properties (load and modulus) were achieved. The load and modulus of the HAp-PCL/CS composite fibers was 250.1N and 215.5MPa, which is very similar to that of standard value of the human tendon and ligament tissues. The cellular responses and biocompatibility of HAp-PCL/CS nanofibrous scaffolds were investigated with human osteoblast (HOS) cells for tendon regeneration and examined the primary osteoblast mechanism by in vitro method. The morphological (FE-SEM and fluorescence) microscopic images clearly exhibited that HOS cells are well attached and flatted on the nanofibrous composites. The HAp dispersed PCL/CS nanofibrous scaffolds promoted higher adhesion and proliferation of HOS cells comparable to the nanofibrous scaffolds without HAp nanoparticles. The physic-chemical and biological properties of the synthesized nanofibrous scaffold were very close to that of normal ligament and tendon in human body. Over all, these studied results confirmed that the prepared nanofibrous scaffolds will be effective biomaterial of tendon ligament regeneration applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Neuronal regulation of tendon homoeostasis

    PubMed Central

    Ackermann, Paul W

    2013-01-01

    The regulation of tendon homoeostasis, including adaptation to loading, is still not fully understood. Accumulating data, however, demonstrates that in addition to afferent (sensory) functions, the nervous system, via efferent pathways which are associated with through specific neuronal mediators plays an active role in regulating pain, inflammation and tendon homeostasis. This neuronal regulation of intact-, healing- and tendinopathic tendons has been shown to be mediated by three major groups of molecules including opioid, autonomic and excitatory glutamatergic neuroregulators. In intact healthy tendons the neuromediators are found in the surrounding structures: paratenon, endotenon and epitenon, whereas the proper tendon itself is practically devoid of neurovascular supply. This neuroanatomy reflects that normal tendon homoeostasis is regulated from the tendon surroundings. After injury and during tendon repair, however, there is extensive nerve ingrowth into the tendon proper, followed by a time-dependent emergence of sensory, autonomic and glutamatergic mediators, which amplify and fine-tune inflammation and regulate tendon regeneration. In tendinopathic condition, excessive and protracted presence of sensory and glutamatergic neuromediators has been identified, suggesting involvement in inflammatory, nociceptive and hypertrophic (degenerative) tissue responses. Under experimental and clinical conditions of impaired (e.g. diabetes) as well as excessive (e.g. tendinopathy) neuromediator release, dysfunctional tendon homoeostasis develops resulting in chronic pain and gradual degeneration. Thus there is a prospect that in the future pharmacotherapy and tissue engineering approaches targeting neuronal mediators and their receptors may prove to be effective therapies for painful, degenerative and traumatic tendon disorders. PMID:23718724

  3. Patch-augmented rotator cuff repair: influence of the patch fixation technique on primary biomechanical stability.

    PubMed

    Jung, Christian; Spreiter, Gregor; Audigé, Laurent; Ferguson, Stephen J; Flury, Matthias

    2016-05-01

    There is an ongoing debate about the potential of patch augmentation to improve biomechanical stability and healing associated with rotator cuff repair. The biomechanical properties of three different patch-augmented rotator cuff repair techniques were assessed in vitro and compared with a standard repair. Dermal collagen patch augmentation may increase the primary stability and strength of the repaired tendon in vitro, depending on the technique used for patch application. Forty cadaveric sheep shoulders with dissected infraspinatus tendons were randomized into four groups (n = 10/group) for tendon repair using a knotless double-row suture anchor technique. A xenologous dermal extracellular matrix patch was used for augmentation in the three test groups using an "integrated", "cover", or "hybrid" technique. Tendons were preconditioned, cyclically loaded from 10 to 30 N at 1 Hz, and then loaded monotonically to failure. Biomechanical properties and the mode of failure were evaluated. Patch augmentation significantly increased the maximum load at failure by 61 % in the "cover" technique test group (225.8 N) and 51 % in the "hybrid" technique test group (211.4 N) compared with the non-augmented control group (140.2 N) (P ≤ 0.015). For the test group with "integrated" patch augmentation, the load at failure was 28 % lower (101.6 N) compared with the control group (P = 0.043). There was no significant difference in initial and linear stiffness among the four experimental groups. The most common mode of failure was tendon pullout. No anchor dislocation, patch disruption or knot breakage was observed. Additional patch augmentation with a collagen patch influences the biomechanical properties of a rotator cuff repair in a cadaveric sheep model. Primary repair stability can be significantly improved depending on the augmentation technique.

  4. Does a critical rotator cuff tear stage exist?: a biomechanical study of rotator cuff tear progression in human cadaver shoulders.

    PubMed

    Oh, Joo Han; Jun, Bong Jae; McGarry, Michelle H; Lee, Thay Q

    2011-11-16

    It is unknown at which stage of rotator cuff tear the biomechanical environment is altered. The purpose of this study was to determine if a critical rotator cuff tear stage exists that alters glenohumeral joint biomechanics throughout the rotational range of shoulder motion, and to evaluate the biomechanical effect of parascapular muscle-loading. Eight cadaver shoulders were used with a custom testing system. Four progressive rotator cuff tear stages were investigated on the basis of footprint anatomy. Three muscle-loading conditions were examined: rotator cuff only; rotator cuff with deltoid muscle; and rotator cuff, deltoid, pectoralis major, and latissimus dorsi muscles. Testing was performed in the scapular plane with 0°, 30°, and 60° of shoulder abduction. The maximum internal and external rotations were measured with 3.4 Nm of torque. The position of the humeral head apex with respect to the glenoid was calculated with use of a MicroScribe 3DLX digitizing system throughout the rotational range of motion. The abduction capability was determined as the abduction angle achieved with increasing deltoid load. Tear of the entire supraspinatus tendon significantly increased maximum external rotation and significantly decreased abduction capability with higher deltoid loads (p < 0.05). Tear of the entire supraspinatus tendon and half of the infraspinatus tendon significantly shifted the humeral head apex posteriorly at the midrange of rotation and superiorly at maximum internal rotation (p < 0.05). Loading the pectoralis major and latissimus dorsi muscles decreased the amount of humeral head elevation due to deltoid loading. Tear of the entire supraspinatus tendon was the critical stage for increasing rotational range of shoulder motion and for decreased abduction capability. Further tear progression to the infraspinatus muscle was the critical stage for significant changes in humeral head kinematics. The pectoralis major and latissimus dorsi muscles played an important role in stabilizing the humeral head as the rotator cuff tear progressed.

  5. The Biomechanical and Histologic Effects of Platelet-Rich Plasma on Rat Rotator Cuff Repairs

    PubMed Central

    Beck, Jennifer; Evans, Douglas; Tonino, Pietro M.; Yong, Sherri; Callaci, John J.

    2013-01-01

    Background Rotator cuff tears are common injuries that are often treated with surgical repair. Because of the high concentration of growth factors within platelets, platelet-rich plasma (PRP) has the potential to enhance healing in rotator cuff repairs. Hypothesis Platelet-rich plasma would alter the biomechanical and histologic properties of rotator cuff repair during an acute injury response. Study Design Controlled laboratory study. Methods Platelet-rich plasma was produced from inbred donor rats. A tendon-from-bone supraspinatus tear was created surgically and an immediate transosseous repair performed. The control group underwent repair only. The PRP group underwent a repair with PRP augmentation. Rats in each group were sacrificed at 7, 14, and 21 days. The surgically repaired tendons underwent biomechanical testing, including failure load, stiffness, failure strain, and stress relaxation characteristics. Histological analysis evaluated the cellular characteristics of the repair tissue. Results At 7- and 21-day periods, augmentation with PRP showed statistically significant effects on the biomechanical properties of the repaired rat supraspinatus tear, but failure load was not increased at the 7-, 14-, or 21-day periods (P = .688, .209, and .477, respectively). The control group had significantly higher stiffness at 21 days (P = .006). The control group had higher failure strain at 7 days (P = .02), whereas the PRP group had higher failure strain at 21 days (P = .008). Histologically, the PRP group showed increased fibroblastic response and vascular proliferation at each time point. At 21 days, the collagen fibers in the PRP group were oriented in a more linear fashion toward the tendon footprint. Conclusion In this controlled, rat model study, PRP altered the tissue properties of the supraspinatus tendon without affecting the construct’s failure load. Clinical Relevance The decreased tendon tissue stiffness acutely and failure to enhance tendon-to-bone healing of repairs should be considered before augmenting rotator cuff repairs with PRP. Further studies will be necessary to determine the role of PRP in clinical practice. PMID:22822177

  6. Does the thickening of Achilles tendon and plantar fascia contribute to the alteration of diabetic foot loading?

    PubMed

    Giacomozzi, C; D'Ambrogi, E; Uccioli, L; Macellari, V

    2005-06-01

    The diabetic foot often undergoes abnormal plantar pressures, changing in walking strategy, ulcerative processes. The present study focuses on the effects that diabetes-induced alterations of Achilles tendon, plantar fascia and first metatarso-phalangeal joint-both anatomical and functional-may have on foot loading. Sixty-one diabetic patients, with or without neuropathy, and 21 healthy volunteers were recruited. Thickness of Achilles tendon and plantar fascia was measured by ultrasound. Flexion-extension of the first metatarso-phalangeal joint was measured passively. Main biomechanic parameters of foot-floor interaction during gait were acquired and related to the above measurements. Plantar fascia and Achilles tendon were significantly (P<0.05) thicker in diabetics than in controls; mean values (SD) for controls, diabetics without and with neuropathy were 2.0 mm (0.5), 2.9 mm (1.2) and 3.0 mm (0.8) for plantar fascia, respectively, and 4.0 mm (0.5), 4.6 mm (1.0) and 4.9 mm (1.7) for Achilles tendon, respectively. Flexion-extension of the first metatarso-phalangeal joint was significantly (P<0.05) smaller in diabetics than in controls; mean values (SD) for controls, diabetics without and with neuropathy were 100.0 degrees (10.0), 54.0 degrees (29.4) and 54.9 degrees (17.2), respectively. The increase in the vertical force under the metatarsals was strongly related (R=0.83, explained variance=70.1%) to the changes in the three above parameters. Thickening of plantar fascia and Achilles tendon in diabetics, more evident in the presence of neuropathy, concurs to develop a rigid foot, which poorly absorbs shock during landing (performs the physiological impact force absorption during landing). More generally, an overall alteration of the foot-ankle complex motion likely occurs throughout the whole gait cycle, which partly explains the abnormal loading under the forefoot.

  7. Influence of Muscle-Tendon Wrapping on Calculations of Joint Reaction Forces in the Equine Distal Forelimb

    PubMed Central

    Merritt, Jonathan S.; Davies, Helen M. S.; Burvill, Colin; Pandy, Marcus G.

    2008-01-01

    The equine distal forelimb is a common location of injuries related to mechanical overload. In this study, a two-dimensional model of the musculoskeletal system of the region was developed and applied to kinematic and kinetic data from walking and trotting horses. The forces in major tendons and joint reaction forces were calculated. The components of the joint reaction forces caused by wrapping of tendons around sesamoid bones were found to be of similar magnitude to the reaction forces between the long bones at each joint. This finding highlighted the importance of taking into account muscle-tendon wrapping when evaluating joint loading in the equine distal forelimb. PMID:18509485

  8. Optimization of intrinsic and extrinsic tendon healing through controllable water-soluble mitomycin-C release from electrospun fibers by mediating adhesion-related gene expression.

    PubMed

    Zhao, Xin; Jiang, Shichao; Liu, Shen; Chen, Shuai; Lin, Zhi Yuan William; Pan, Guoqing; He, Fan; Li, Fengfeng; Fan, Cunyi; Cui, Wenguo

    2015-08-01

    To balance intrinsic and extrinsic healing during tendon repair is challenging in tendon surgery. We hypothesized that by mediating apoptotic gene and collagen synthesis of exogenous fibroblasts, the adhesion formation induced by extrinsic healing could be inhibited. With the maintenance of intrinsic healing, the tendon could be healed with proper function with no adhesion. In this study, we loaded hydrophilic mitomycin-C (MMC) into hyaluronan (HA) hydrosols, which were then encapsulated in poly(L-lactic acid) (PLLA) fibers by micro-sol electrospinning. This strategy successfully provided a controlled release of MMC to inhibit adhesion formations with no detrimental effect on intrinsic healing. We found that micro-sol electrospinning was an effective and facile approach to incorporate and control hydrophilic drug release from hydrophobic polyester fibers. MMC exhibited an initially rapid, and gradually steadier release during 40 days, and the release rates could be tuned by its concentration. In vitro studies revealed that low concentrations of MMC could inhibit fibroblast adhesion and proliferation. When lacerate tendons were healed using the MMC-HA loaded PLLA fibers in vivo, they exhibited comparable mechanical strength to the naturally healed tendons but with no significant presence of adhesion formation. We further identified the up-regulation of apoptotic protein Bax expression and down-regulation of proteins Bcl2, collage I, collagen III and α-SMA during the healing process associated with minimum adhesion formations. This approach presented here leverages new advances in drug delivery and nanotechnology and offers a promising strategy to balance intrinsic and extrinsic tendon healing through modulating genes associated with fibroblast apoptosis and collagen synthesis. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Postinjury biomechanics of Achilles tendon vary by sex and hormone status

    PubMed Central

    Fryhofer, George W.; Freedman, Benjamin R.; Hillin, Cody D.; Salka, Nabeel S.; Pardes, Adam M.; Weiss, Stephanie N.; Farber, Daniel C.

    2016-01-01

    Achilles tendon ruptures are common injuries. Sex differences are present in mechanical properties of uninjured Achilles tendon, but it remains unknown if these differences extend to tendon healing. We hypothesized that ovariectomized females (OVX) and males would exhibit inferior postinjury tendon properties compared with females. Male, female, and OVX Sprague-Dawley rats (n = 32/group) underwent acclimation and treadmill training before blunt transection of the Achilles tendon midsubstance. Injured hindlimbs were immobilized for 1 wk, followed by gradual return to activity and assessment of active and passive hindlimb function. Animals were euthanized at 3 or 6 wk postinjury to assess tendon structure, mechanics, and composition. Passive ankle stiffness and range of motion were superior in females at 3 wk; however, by 6 wk, passive and active function were similar in males and females but remained inferior in OVX. At 6 wk, female tendons had greater normalized secant modulus, viscoelastic behavior, and laxity compared with males. Normalized secant modulus, cross-sectional area and tendon glycosaminoglycan composition were inferior in OVX compared with females at 6 wk. Total fatigue cycles until tendon failure were similar among groups. Postinjury muscle fiber size was better preserved in females compared with males, and females had greater collagen III at the tendon injury site compared with males at 6 wk. Despite male and female Achilles tendons withstanding similar durations of fatigue loading, early passive hindlimb function and tendon mechanical properties, including secant modulus, suggest superior healing in females. Ovarian hormone loss was associated with inferior Achilles tendon healing. PMID:27633741

  10. Advanced age diminishes tendon-to-bone healing in a rat model of rotator cuff repair.

    PubMed

    Plate, Johannes F; Brown, Philip J; Walters, Jordan; Clark, John A; Smith, Thomas L; Freehill, Michael T; Tuohy, Christopher J; Stitzel, Joel D; Mannava, Sandeep

    2014-04-01

    Advanced patient age is associated with recurrent tearing and failure of rotator cuff repairs clinically; however, basic science studies have not evaluated the influence of aging on tendon-to-bone healing after rotator cuff repair in an animal model. Hypothesis/ This study examined the effect of aging on tendon-to-bone healing in an established rat model of rotator cuff repair using the aged animal colony from the National Institute on Aging of the National Institutes of Health. The authors hypothesized that normal aging decreases biomechanical strength and histologic organization at the tendon-to-bone junction after acute repair. Controlled laboratory study. In 56 F344xBN rats, 28 old and 28 young (24 and 8 months of age, respectively), the supraspinatus tendon was transected and repaired. At 2 or 8 weeks after surgery, shoulder specimens underwent biomechanical testing to compare load-to-failure and load-relaxation response between age groups. Histologic sections of the tendon-to-bone interface were assessed with hematoxylin and eosin staining, and collagen fiber organization was assessed by semiquantitative analysis of picrosirius red birefringence under polarized light. Peak failure load was similar between young and old animals at 2 weeks after repair (31% vs 26% of age-matched uninjured controls, respectively; P > .05) but significantly higher in young animals compared with old animals 8 weeks after repair (86% vs 65% of age-matched uninjured controls, respectively; P < .01). Eight weeks after repair, fibroblasts appeared more organized and uniformly aligned in young animals on hematoxylin and eosin slides compared with old animals. Collagen birefringence analysis of the tendon-to-bone junction demonstrated that young animals had increased collagen fiber organization and similar histologic structure compared with age-matched controls (53.7 ± 2.4 gray scales; P > .05). In contrast, old animals had decreased collagen fiber organization and altered structure compared with age-matched controls (49.8 ± 3.1 gray scales; P < .01). In a rat model of aging, old animals demonstrated diminished tendon-to-bone healing after rotator cuff injury and repair. Old animals had significantly decreased failure strength and collagen fiber organization at the tendon-to-bone junction compared with young animals. This study implies that animal age may need to be considered in future studies of rotator cuff repair in animal models. With increasing age and activity level of the population, the incidence of rotator cuff tears is predicted to rise. Despite advances in rotator cuff repair technique, the retear rate remains specifically high in elderly patients. The findings of this research suggest that aging negatively influences tendon-to-bone healing after rotator cuff repair in a validated animal model.

  11. Effect of the Interposition of Calcium Phosphate Materials on Tendon-Bone Healing During Repair of Chronic Rotator Cuff Tear.

    PubMed

    Zhao, Song; Peng, Lingjie; Xie, Guoming; Li, Dingfeng; Zhao, Jinzhong; Ning, Congqin

    2014-08-01

    The current nature of tendon-bone healing after rotator cuff (RC) repair is still the formation of granulation tissue at the tendon-bone interface rather than the formation of fibrocartilage, which is the crucial structure in native tendon insertion and can be observed after knee ligament reconstruction. The interposition of calcium phosphate materials has been found to be able to enhance tendon-bone healing in knee ligament reconstruction. However, whether the interposition of these kinds of materials can enhance tendon-bone healing or even change the current nature of tendon-bone healing after RC repair still needs to be explored. The interposition of calcium phosphate materials during RC repair would enhance tendon-bone healing or change its current nature of granulation tissue formation into a more favorable process. Controlled laboratory study. A total of 144 male Sprague-Dawley rats underwent unilateral detachment of the supraspinatus tendon, followed by delayed repair after 3 weeks. The animals were allocated into 1 of 3 groups: (1) repair alone, (2) repair with Ca5(PO4)2SiO4 (CPS) bioceramic interposition, or (3) repair with hydroxyapatite (HA) bioceramic interposition at the tendon-bone interface. Animals were sacrificed at 2, 4, or 8 weeks postoperatively, and microcomputed tomography (micro-CT) was used to quantify the new bone formation at the repair site. New fibrocartilage formation and collagen organization at the tendon-bone interface was evaluated by histomorphometric analysis. Biomechanical testing of the supraspinatus tendon-bone complex was performed. Statistical analysis was performed using 1-way analysis of variance. Significance was set at P < .05. The micro-CT analysis demonstrated remarkable osteogenic activity and osteoconductivity to promote new bone formation and ingrowth of CPS and HA bioceramic, with CPS bioceramic showing better results than HA. Histological observations indicated that CPS bioceramic had excellent biocompatibility and biodegradability. At early time points after the RC repair, CPS bioceramic significantly increased the area of fibrocartilage at the tendon-bone interface compared with the control and HA groups. Moreover, CPS and HA bioceramics had significantly improved collagen organization. Biomechanical tests indicated that the CPS and HA groups have greater ultimate load to failure and stiffness than the control group at 4 and 8 weeks, and the CPS specimens exhibited the maximum ultimate load to failure, stiffness, and stress of the healing enthesis. Both CPS and HA bioceramics aid in cell attachment and proliferation and accelerate new bone formation, and CPS bioceramic has a more prominent effect on tendon-to-bone healing. Local application of CPS and HA bioceramic at the tendon-bone interface shows promise in improving healing after rotator cuff tear repair. © 2014 The Author(s).

  12. Novel technique for repairing posterior medial meniscus root tears using porcine knees and biomechanical study.

    PubMed

    Wu, Jia-Lin; Lee, Chian-Her; Yang, Chan-Tsung; Chang, Chia-Ming; Li, Guoan; Cheng, Cheng-Kung; Chen, Chih-Hwa; Huang, Hsu-Shan; Lai, Yu-Shu

    2018-01-01

    Transtibial pullout suture (TPS) repair of posterior medial meniscus root (PMMR) tears was shown to achieve good clinical outcomes. The purpose of this study was to compare biomechanically, a novel technique designed to repair PMMR tears using tendon graft (TG) and conventional TPS repair. Twelve porcine tibiae (n = 6 each) TG group: flexor digitorum profundus tendon was passed through an incision in the root area, created 5 mm postero-medially along the edge of the attachment area. TPS group: a modified Mason-Allen suture was created using no. 2 FiberWire. The tendon grafts and sutures were threaded through the bone tunnel and then fixed to the anterolateral cortex of the tibia. The two groups underwent cyclic loading followed by a load-to-failure test. Displacements of the constructs after 100, 500, and 1000 loading cycles, and the maximum load, stiffness, and elongation at failure were recorded. The TG technique had significantly lower elongation and higher stiffness compared with the TPS. The maximum load of the TG group was significantly lower than that of the TPS group. Failure modes for all specimens were caused by the suture or graft cutting through the meniscus. Lesser elongation and higher stiffness of the constructs in TG technique over those in the standard TPS technique might be beneficial for postoperative biological healing between the meniscus and tibial plateau. However, a slower rehabilitation program might be necessary due to its relatively lower maximum failure load.

  13. [Prevention and repair of patellar ligament injury in total knee arthroplasty].

    PubMed

    Bian, Yanyan; Weng, Xisheng

    2013-09-01

    To review the progress in the prevention and repair of patellar ligament injury in total knee Recent literature about the prevention and repair of patellar ligament injury in total knee arthroplasty arthroplasty. was reviewed and analyzed. Increased exposure can prevent the patellar ligament injury, and treatments of acute patellar ligament rupture can be obtained by simple repair, reconstruction with allograft materials or artificial materials, and auxiliary strengthening. Patellar ligament injury in total knee arthroplasty should not be ignored. Active prevention and repair of patellar ligament injury can obtain better function of knee joint.

  14. Shoulder abduction diminishes self-reinforcement in transosseous-equivalent rotator cuff repair in both knotted and knotless techniques.

    PubMed

    Smith, Geoffrey C S; Lam, Patrick H

    2018-06-20

    The self-reinforcement mechanism after double row suturebridge rotator cuff repair generates increasing compressive forces at the tendon footprint with increasing tendon load. Passive range of motion is usually allowed after rotator cuff repair. The mechanism of self-reinforcement could be adversely affected by shoulder abduction. Rotator cuff tears were created ex vivo in nine pairs of ovine shoulders. Two different repair techniques were used. One group was repaired using a double row 'suturebridge' construct with tied horizontal medial row mattress sutures (Knotted repair group). The other group was repaired identically except that medial row knots were not tied (Knotless repair group). Footprint compression was measured at varying amounts of abduction and under tendon loads of 0, 10, 20, 30, 40, 50 and 60N. The rate of increase of contact pressure (degree of self-reinforcement) was calculated for each abduction angle. Abduction diminishes footprint contact pressure in both knotted and knotless double row suturebridge constructs. Progressive abduction from 0 to 40 abduction in the knotless group and 0-30 in the knotted group results in a decrease in self-reinforcement. Abduction beyond this does not cause a further decrease in self-reinforcement. There was no difference in the rate of increase of footprint contact pressure at each angle of abduction when comparing the knotted and knotless groups. In the post-operative period, high tendon load combined with minimal abduction would be expected to generate the greatest amount of footprint compression which may improve tendon healing. Therefore, to maximize footprint compression the use of abduction pillows should be avoided while early isometric strengthening should be used.

  15. It's positive to be negative: Achilles tendon work loops during human locomotion.

    PubMed

    Zelik, Karl E; Franz, Jason R

    2017-01-01

    Ultrasound imaging is increasingly used with motion and force data to quantify tendon dynamics during human movement. Frequently, tendon dynamics are estimated indirectly from muscle fascicle kinematics (by subtracting muscle from muscle-tendon unit length), but there is mounting evidence that this Indirect approach yields implausible tendon work loops. Since tendons are passive viscoelastic structures, when they undergo a loading-unloading cycle they must exhibit a negative work loop (i.e., perform net negative work). However, prior studies using this Indirect approach report large positive work loops, often estimating that tendons return 2-5 J of elastic energy for every 1 J of energy stored. More direct ultrasound estimates of tendon kinematics have emerged that quantify tendon elongations by tracking either the muscle-tendon junction or localized tendon tissue. However, it is unclear if these yield more plausible estimates of tendon dynamics. Our objective was to compute tendon work loops and hysteresis losses using these two Direct tendon kinematics estimates during human walking. We found that Direct estimates generally resulted in negative work loops, with average tendon hysteresis losses of 2-11% at 1.25 m/s and 33-49% at 0.75 m/s (N = 8), alluding to 0.51-0.98 J of tendon energy returned for every 1 J stored. We interpret this finding to suggest that Direct approaches provide more plausible estimates than the Indirect approach, and may be preferable for understanding tendon energy storage and return. However, the Direct approaches did exhibit speed-dependent trends that are not consistent with isolated, in vitro tendon hysteresis losses of about 5-10%. These trends suggest that Direct estimates also contain some level of error, albeit much smaller than Indirect estimates. Overall, this study serves to highlight the complexity and difficulty of estimating tendon dynamics non-invasively, and the care that must be taken to interpret biological function from current ultrasound-based estimates.

  16. The microstructure and micromechanics of the tendon-bone insertion

    NASA Astrophysics Data System (ADS)

    Rossetti, L.; Kuntz, L. A.; Kunold, E.; Schock, J.; Müller, K. W.; Grabmayr, H.; Stolberg-Stolberg, J.; Pfeiffer, F.; Sieber, S. A.; Burgkart, R.; Bausch, A. R.

    2017-06-01

    The exceptional mechanical properties of the load-bearing connection of tendon to bone rely on an intricate interplay of its biomolecular composition, microstructure and micromechanics. Here we identify that the Achilles tendon-bone insertion is characterized by an interface region of ~500 μm with a distinct fibre organization and biomolecular composition. Within this region, we identify a heterogeneous mechanical response by micromechanical testing coupled with multiscale confocal microscopy. This leads to localized strains that can be larger than the remotely applied strain. The subset of fibres that sustain the majority of loading in the interface area changes with the angle of force application. Proteomic analysis detects enrichment of 22 proteins in the interfacial region that are predominantly involved in cartilage and skeletal development as well as proteoglycan metabolism. The presented mechanisms mark a guideline for further biomimetic strategies to rationally design hard-soft interfaces.

  17. Proximo-distal patellar position in three small dog breeds with medial patellar luxation.

    PubMed

    Wangdee, C; Theyse, L F H; Hazewinkel, H A W

    2015-01-01

    Medial patellar luxation is thought to be associated with a high proximal position of the patella in the trochlear groove. To determine whether the ratio of patellar ligament length and patellar length (L:P) is influenced by the stifle angle (75°, 96°, 113°, 130°, and 148°) in small dog breeds and to compare the L:P ratio in dogs of three small dog breeds with and without medial patellar luxation. A mediolateral radiograph of the stifle joint was used to measure the L:P ratio in the stifle joints of dogs of three small breeds with and without medial patellar luxation. The L:P ratio was evaluated at five stifle angles (75°, 96°, 113°, 130°, and 148°) in 14 cadavers (26 stifle joints) of small dog breeds in order to identify the best stifle angle to measure the L:P ratio. Then the mean ± SD L:P ratio was calculated for normal stifles and stifles with medial patellar luxation grades 1, 2, and 3 in 194 Pomeranians, 74 Chihuahuas, and 41 Toy or Standard Poodles. The L:P ratio was the same for all five stifle angles in the cadavers (p = 0.195). It was also not significantly different in the three breeds (p = 0.135), in normal and medial patellar luxation-affected stifles overall (p = 0.354), and in normal and medial patellar luxation-affected joints within each breed (p = 0.19). We conclude that a proximo-distal patellar position is not associated with medial patellar luxation in Pomeranians, Chihuahuas, and Toy or Standard Poodles. Thus a longer patellar ligament length does not play a role in the pathophysiology of medial patellar luxation in these small dog breeds.

  18. 5. Recent advances in sports medicine.

    PubMed

    Brukner, Peter D; Crossley, Kay M; Morris, Hayden; Bartold, Simon J; Elliott, Bruce

    2006-02-20

    New research has changed our perception and management of common injuries. Magnetic resonance imaging and arthroscopy of the hip have shown that labral injuries, chondral injuries, rim lesions, synovitis and tears of the ligament teres are common causes of hip, groin and low-back pain. Hip arthroscopy is used both as a diagnostic and therapeutic tool; it has been shown to be of benefit in recent traumatic labral injury, but disappointing in the management of chronic hip pain (which may be associated with degenerative change, and chondral lesions of the acetabulum). The McConnell multimodal physiotherapy regimen is effective in treating patellofemoral pain. Anterior cruciate ligament rupture is three to five times more common in women, but neuromuscular training appears to decrease its incidence. Patellar tendon and hamstring grafts appear to be equally effective in anterior cruciate ligament reconstruction. Articular cartilage defects remain a significant problem, and the efficacy of treatments such as autologous chondrocyte implantation is still unclear.

  19. Tendinopathies and platelet-rich plasma (PRP): from pre-clinical experiments to therapeutic use

    PubMed Central

    Kaux, Jean-François; Drion, Pierre; Croisier, Jean-Louis; Crielaard, Jean-Michel

    2015-01-01

    Objectives: The restorative properties of platelets, through the local release of growth factors, are used in various medical areas. This article reviews fundamental and clinical research relating to platelet-rich plasma applied to tendinous lesions. Materials and method: Articles in French and English, published between 1 January 2012 and 31 December 2014. dealing with PRP and tendons were searched for using the Medline and Scopus data bases. Results: Forty-seven articles were identified which addressed pre-clinical and clinical studies: 27 relating to in vitro and in vivo animal studies and 20 relating to human studies. Of these, five addressed lateral epicondylitis, two addressed rotator cuff tendinopathies, ten dealt with patellar tendinopathies and three looked at Achilles tendinopathies. Conclusions: The majority of pre-clinical studies show that PRP stimulates the tendon’s healing process. However, clinical series remain more controversial and level 1, controlled, randomised studies are still needed. PMID:26195890

  20. Total Knee Arthroplasty for Osteoarthritis Secondary to Fracture of the Tibial Plateau. A Prospective Matched Cohort Study.

    PubMed

    Lizaur-Utrilla, Alejandro; Collados-Maestre, Isabel; Miralles-Muñoz, Francisco A; Lopez-Prats, Fernando A

    2015-08-01

    A prospective matched cohort study was performed to compare outcomes of total knee arthroplasties (TKA) between 29 patients with posttraumatic osteoarthritis (POA) after a fracture of tibial plateau and 58 patients underwent routine TKA. Mean follow-up was 6.7 years. There were no significant differences in KSS, WOMAC, SF12 scores or range of motion. In the control group there were no complications. In the posttraumatic group, complications occurred in 4 patients (13.7%) (P=0.010) including partial patellar tendon detachment, superficial infection, skin necrosis, and knee stiffness. Only this last patient required revision for manipulation under anesthesia. Also, there was a revision for tibial aseptic loosening in each group. TKA is an effective treatment for POA after tibial plateau fracture. We recommend the prior removal of hardware, as well as tibial tubercle osteotomy when necessary. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Gastric pentadecapeptide BPC 157 accelerates healing of transected rat Achilles tendon and in vitro stimulates tendocytes growth.

    PubMed

    Staresinic, M; Sebecic, B; Patrlj, L; Jadrijevic, S; Suknaic, S; Perovic, D; Aralica, G; Zarkovic, N; Borovic, S; Srdjak, M; Hajdarevic, K; Kopljar, M; Batelja, L; Boban-Blagaic, A; Turcic, I; Anic, T; Seiwerth, S; Sikiric, P

    2003-11-01

    In studies intended to improve healing of transected Achilles tendon, effective was a stable gastric pentadecapeptide BPC 157 (GEPPPGKPADDAGLV, M.W. 1419). Currently in clinical trials for inflammatory bowel disease (PLD-116, PL 14736, Pliva), it ameliorates internal and external wound healing. In rats, the right Achilles tendon transected (5 mm proximal to its calcaneal insertion) presents with a large tendon defect between cut ends. Agents (/kg b.w., i.p., once time daily) (BPC 157 (dissolved in saline, with no carrier addition) (10 microg, 10 ng or 10 pg) or saline (5.0 ml)), were firstly applied at 30 min after surgery, the last application at 24 h before autopsy. Achilles functional index (AFI) was assessed once time daily. Biomechanical, microscopical and macroscopical assessment was on day 1, 4, 7, 10 and 14. Controls generally have severely compromised healing. In comparison, pentadecapeptide BPC 157 fully improves recovery: (i) biomechanically, increased load of failure, load of failure per area and Young's modulus of elasticity; (ii) functionally, significantly higher AFI-values; (iii) microscopically, more mononuclears and less granulocytes, superior formation of fibroblasts, reticulin and collagen; (iv) macroscopically, smaller size and depth of tendon defect, and subsequently the reestablishment of full tendon integrity. Likewise, unlike TGF-beta, pentadecapeptide BPC 157, presenting with no effect on the growth of cultured cell of its own, consistently opposed 4-hydroxynonenal (HNE), a negative modulator of the growth. HNE-effect is opposed in both combinations: BPC 157+HNE (HNE growth inhibiting effect reversed into growth stimulation of cultured tendocytes) and HNE+BPC 157(abolished inhibiting activity of the aldehyde), both in the presence of serum and serum deprived conditions. In conclusion, these findings, particularly, Achilles tendon transection fully recovered in rats, peptide stability suitable delivery, usefully favor gastric pentadecapeptide BPC 157 in future Achilles tendon therapy.

  2. Effects of braiding on tensile properties of four-strand human hamstring tendon grafts.

    PubMed

    Millett, Peter J; Miller, Bruce S; Close, Matthew; Sterett, William I; Walsh, William; Hawkins, Richard J

    2003-01-01

    Anterior cruciate ligament reconstruction is commonly performed with autogenous hamstring tendon grafts. To ascertain the effects of braiding on ultimate tensile strength and stiffness of hamstring tendon graft. Controlled laboratory study. Sixteen fresh-frozen semitendinosus and gracilis tendons were harvested from eight matched (right and left) human cadaveric specimens. Both sets of hamstring tendons from each matched pair were doubled, creating a four-strand graft. Grafts were then randomized so that one graft from each matched pair was braided and the other remained unbraided. The diameter of each graft construct was recorded. Grafts were tested to failure on a materials testing machine. There were no significant differences in cross-sectional area before or after braiding. Fifteen of 16 tendons failed midsubstance; 1 failed at the lower clamp. Braiding reduced the initial tensile strength and stiffness of human hamstring tendon grafts in this study by 35.0% and 45.8%, respectively. Braiding may place the collagen fibers in a suboptimal orientation for loading that results in a weaker graft. We do not recommend the use of braiding if the strongest, stiffest initial graft is desired.

  3. Current Concepts in Examination and Treatment of Elbow Tendon Injury

    PubMed Central

    Ellenbecker, Todd S.; Nirschl, Robert; Renstrom, Per

    2013-01-01

    Context: Injuries to the tendons of the elbow occur frequently in the overhead athlete, creating a significant loss of function and dilemma to sports medicine professionals. A detailed review of the anatomy, etiology, and pathophysiology of tendon injury coupled with comprehensive evaluation and treatment information is needed for clinicians to optimally design treatment programs for rehabilitation and prevention. Evidence Acquisitions: The PubMed database was searched in January 2012 for English-language articles pertaining to elbow tendon injury. Results: Detailed information on tendon pathophysiology was found along with incidence of elbow injury in overhead athletes. Several evidence-based reviews were identified, providing a thorough review of the recommended rehabilitation for elbow tendon injury. Conclusions: Humeral epicondylitis is an extra-articular tendon injury that is common in athletes subjected to repetitive upper extremity loading. Research is limited on the identification of treatment modalities that can reduce pain and restore function to the elbow. Eccentric exercise has been studied in several investigations and, when coupled with a complete upper extremity strengthening program, can produce positive results in patients with elbow tendon injury. Further research is needed in high-level study to delineate optimal treatment methods. PMID:24427389

  4. Effects of corticosteroids and hyaluronic acid on torn rotator cuff tendons in vitro and in rats.

    PubMed

    Nakamura, Hidehiro; Gotoh, Masafumi; Kanazawa, Tomonoshin; Ohta, Keisuke; Nakamura, Keiichirou; Honda, Hirokazu; Ohzono, Hiroki; Shimokobe, Hisao; Mitsui, Yasuhiro; Shirachi, Isao; Okawa, Takahiro; Higuchi, Fujio; Shirahama, Masahiro; Shiba, Naoto; Matsueda, Satoko

    2015-10-01

    Corticosteroids (CS) or hyaluronic acid (HA) is used in subacromial injection for the conservative treatment of rotator cuff tears (RCT); this study addresses the question of how CS and HA affect the tendon tissue and fibroblasts in vitro and in rats. Cell proliferation assays were performed in human tendon fibroblasts from RCT. Rats underwent surgery to create RCT, and the surgical sites were injected with CS or HA. The rotator cuff tendons were subjected to biomechanical testing, microscopic and immunohistochemical analysis of proliferating cell nuclear antigen (PCNA), and ultrastructural analysis. Cell proliferation was significantly decreased with CS in vitro (p < 0.05). Maximal load of CS-treated tendons was significantly decreased compared with that of HA-treated tendons (p < 0.05), as well as PCNA(+) cells at 2 weeks (p < 0.05). Ultrastructural observations of the CS-treated rats detected apoptosis of tendon fibroblasts 24 h after surgery. Histological and biomechanical data 4 weeks after surgery were not significant among the three groups. Unlike HA, CS caused cell death, and inhibition of the proliferation of tendon fibroblasts, leading to a delay of tendon healing involved and a subsequent decrease of biomechanical strength at the surgical site. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  5. Should the position of the patellar component replicate the vertical median ridge of the native patella?

    PubMed

    Lee, Rae Hyeong; Jeong, Hae Won; Lee, Jin Kyu; Choi, Choong Hyeok

    2017-01-01

    In total knee arthroplasty (TKA), the position of the patellar component can affect patellar tracking. However, the patellar component cannot always replicate the original high point of the patella because of anatomical variance. This study investigated whether altering the highest point of the patella can affect outcomes of primary TKA, especially in patients having a patella with a far-medialized median ridge. A retrospective review was performed for 177 knees (143 patients) treated with primary TKA between July 2011 and March 2014. Group 1 (34 knees) had the patellar component displaced over three millimeters from the median ridge, while Group 2 (143 knees) had the patellar component placed on the original median ridge position. The one-year follow-up outcomes were reviewed, including: patellar tilt angle, Knee Society Score, Feller Patellar Score, and modified Kujala Anterior Knee Pain Score. Mean (±standard deviation) displacement of the patellar component in Group 1 was 3.97±0.97mm lateral to the original position of the median ridge, with a significant decrease in lateral patellar tilt angle (P<0.001). Lateral patellar tilt showed a positive correlation with the medialization of the patellar component (P<0.001, r=0.401). Ability to rise from a chair was better in Group 1 (P=0.025). There were no other between-group differences in other clinical outcomes. There should be no need for the patellar component to replicate the original highest point of the native patella in primary TKA. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Obesity as a Risk Factor for Tendinopathy: A Systematic Review

    PubMed Central

    Franceschi, Francesco; Papalia, Rocco; Franceschetti, Edoardo; Denaro, Vincenzo

    2014-01-01

    Purpose. In the last few years, evidence has emerged to support the possible association between increased BMI and susceptibility to some musculoskeletal diseases. We systematically review the literature to clarify whether obesity is a risk factor for the onset of tendinopathy. Methods. We searched PubMed, Cochrane Central, and Embase Biomedical databases using the keywords “obesity,” “overweight,” and “body mass index” linked in different combinations with the terms “tendinopathy,” “tendinitis,” “tendinosis,” “rotator cuff,” “epicondylitis,” “wrist,” “patellar,” “quadriceps,” “Achilles,” “Plantar Fascia,” and “tendon.” Results. Fifteen studies were included. No level I study on this subject was available, and the results provided are ambiguous. However, all the 5 level II studies report the association between obesity measured in terms of BMI and tendon conditions, with OR ranging between 1.9 (95% CI: 1.1–2.2) and 5.6 (1.9–16.6). Conclusions. The best evidence available to date indicates that obesity is a risk factor for tendinopathy. Nevertheless, further studies should be performed to establish the real strength of the association for each type of tendinopathy, especially because the design of the published studies does not allow identifying a precise cause-effect relationship and the specific role of obesity independently of other metabolic conditions. PMID:25214839

  7. Enhancing the Biomechanical Performance of Anisotropic Nanofibrous Scaffolds in Tendon Tissue Engineering: Reinforcement with Cellulose Nanocrystals.

    PubMed

    Domingues, Rui M A; Chiera, Silvia; Gershovich, Pavel; Motta, Antonella; Reis, Rui L; Gomes, Manuela E

    2016-06-01

    Anisotropically aligned electrospun nanofibrous scaffolds based on natural/synthetic polymer blends have been established as a reasonable compromise between biological and biomechanical performance for tendon tissue engineering (TE) strategies. However, the limited tensile properties of these biomaterials restrict their application in this field due to the load-bearing nature of tendon/ligament tissues. Herein, the use of cellulose nanocrystals (CNCs) as reinforcing nanofillers in aligned electrospun scaffolds based on a natural/synthetic polymer blend matrix, poly-ε-caprolactone/chitosan (PCL/CHT) is reported. The incorporation of small amounts of CNCs (up to 3 wt%) into tendon mimetic nanofiber bundles has a remarkable biomaterial-toughing effect (85% ± 5%, p < 0.0002) and raises the scaffolds mechanical properties to tendon/ligament relevant range (σ = 39.3 ± 1.9 MPa and E = 540.5 ± 83.7 MPa, p < 0.0001). Aligned PCL/CHT/CNC nanocomposite fibrous scaffolds meet not only the mechanical requirements for tendon TE applications but also provide tendon mimetic extracellular matrix (ECM) topographic cues, a key feature for maintaining tendon cell's morphology and behavior. The strategy proposed here may be extended to other anisotropic aligned nanofibrous scaffolds based on natural/synthetic polymer blends and enable the full exploitation of the advantages provided by their tendon mimetic fibrous structures in tendon TE. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Modulation of muscle-tendon interaction in the human triceps surae during an energy dissipation task.

    PubMed

    Werkhausen, Amelie; Albracht, Kirsten; Cronin, Neil J; Meier, Rahel; Bojsen-Møller, Jens; Seynnes, Olivier R

    2017-11-15

    The compliance of elastic elements allows muscles to dissipate energy safely during eccentric contractions. This buffering function is well documented in animal models but our understanding of its mechanism in humans is confined to non-specific tasks, requiring a subsequent acceleration of the body. The present study aimed to examine the behaviour of the human triceps surae muscle-tendon unit (MTU) during a pure energy dissipation task, under two loading conditions. Thirty-nine subjects performed a single-leg landing task, with and without added mass. Ultrasound measurements were combined with three-dimensional kinematics and kinetics to determine instantaneous length changes of MTUs, muscle fascicles, Achilles tendon and combined elastic elements. Gastrocnemius and soleus MTUs lengthened during landing. After a small concentric action, fascicles contracted eccentrically during most of the task, whereas plantar flexor muscles were activated. Combined elastic elements lengthened until peak ankle moment and recoiled thereafter, whereas no recoil was observed for the Achilles tendon. Adding mass resulted in greater negative work and MTU lengthening, which were accompanied by a greater stretch of tendon and elastic elements and a greater recruitment of the soleus muscle, without any further fascicle strain. Hence, the buffering action of elastic elements delimits the maximal strain and lengthening velocity of active muscle fascicles and is commensurate with loading constraints. In the present task, energy dissipation was modulated via greater MTU excursion and more forceful eccentric contractions. The distinct strain pattern of the Achilles tendon supports the notion that different elastic elements may not systematically fulfil the same function. © 2017. Published by The Company of Biologists Ltd.

  9. Experimental evaluation of multiscale tendon mechanics.

    PubMed

    Fang, Fei; Lake, Spencer P

    2017-07-01

    Tendon's primary function is a mechanical link between muscle and bone. The hierarchical structure of tendon and specific compositional constituents are believed to be critical for proper mechanical function. With increased appreciation for tendon importance and the development of various technological advances, this review paper summarizes recent experimental approaches that have been used to study multiscale tendon mechanics, includes an overview of studies that have evaluated the role of specific tissue constituents, and also proposes challenges/opportunities facing tendon study. Tendon has been demonstrated to have specific structural characteristics (e.g., multi-level hierarchy, crimp pattern, helix) and complex mechanical properties (e.g., non-linearity, anisotropy, viscoelasticity). Physical mechanisms including uncrimping, fiber sliding, and collagen reorganization have been shown to govern tendon mechanical responses under both static and dynamic loading. Several tendon constituents with relatively small quantities have been suggested to play a role in its mechanics, although some results are conflicting. Further research should be performed to understand the interplay and communication of tendon mechanical properties across levels of the hierarchical structure, and further show how each of these components contribute to tendon mechanics. The studies summarized and discussed in this review have helped elucidate important aspects of multiscale tendon mechanics, which is a prerequisite for analyzing stress/strain transfer between multiple scales and identifying key principles of mechanotransduction. This information could further facilitate interpreting the functional diversity of tendons from different species, different locations, and even different developmental stages, and then better understand and identify fundamental concepts related to tendon degeneration, disease, and healing. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1353-1365, 2017. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  10. The Effect of Patellar Thickness on Intraoperative Knee Flexion and Patellar Tracking in Patients With Arthrofibrosis Undergoing Total Knee Arthroplasty.

    PubMed

    Kim, Abraham D; Shah, Vivek M; Scott, Richard D

    2016-05-01

    We evaluated the intraoperative effect of patellar thickness on intraoperative passive knee flexion and patellar tracking during total knee arthroplasty (TKA) in patients with preoperative arthrofibrosis and compared them to patients with normal preoperative range of motion (ROM) documented in a prior study. Routine posterior cruciate ligament-retaining TKA was performed in a total of 34 knees, 23 with normal ROM and 11 with arthrofibrosis, defined as ≤100° of passive knee flexion against gravity under anesthesia. Once clinical balance and congruent patellar tracking were established, custom trial patellar components thicker than the standard trial by 2-mm increments (2-8 mm) were sequentially placed and trialed. Passive flexion against gravity was recorded using digital photograph goniometry. Gross mechanics of patellofemoral tracking were visually assessed. On average, passive knee flexion decreased 2° for every 2-mm increment of patellar thickness (P < .0001), which was similar to patients with normal preoperative ROM. In addition, increased patellar thickness had no gross effect on patellar subluxation and tilt in patients with arthrofibrosis as well as those with normal ROM. Patellar thickness had a modest effect on intraoperative passive flexion and no effect on patellar tracking in patients with arthrofibrosis undergoing TKA. There was no marked difference in intraoperative flexion and patellar tracking between patients with arthrofibrosis and patients with normal preoperative ROM. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Ultrasound elasticity imaging of human posterior tibial tendon

    NASA Astrophysics Data System (ADS)

    Gao, Liang

    Posterior tibial tendon dysfunction (PTTD) is a common degenerative condition leading to a severe impairment of gait. There is currently no effective method to determine whether a patient with advanced PTTD would benefit from several months of bracing and physical therapy or ultimately require surgery. Tendon degeneration is closely associated with irreversible degradation of its collagen structure, leading to changes to its mechanical properties. If these properties could be monitored in vivo, it could be used to quantify the severity of tendonosis and help determine the appropriate treatment. Ultrasound elasticity imaging (UEI) is a real-time, noninvasive technique to objectively measure mechanical properties in soft tissue. It consists of acquiring a sequence of ultrasound frames and applying speckle tracking to estimate displacement and strain at each pixel. The goals of my dissertation were to 1) use acoustic simulations to investigate the performance of UEI during tendon deformation with different geometries; 2) develop and validate UEI as a potentially noninvasive technique for quantifying tendon mechanical properties in human cadaver experiments; 3) design a platform for UEI to measure mechanical properties of the PTT in vivo and determine whether there are detectable and quantifiable differences between healthy and diseased tendons. First, ultrasound simulations of tendon deformation were performed using an acoustic modeling program. The effects of different tendon geometries (cylinder and curved cylinder) on the performance of UEI were investigated. Modeling results indicated that UEI accurately estimated the strain in the cylinder geometry, but underestimated in the curved cylinder. The simulation also predicted that the out-of-the-plane motion of the PTT would cause a non-uniform strain pattern within incompressible homogeneous isotropic material. However, to average within a small region of interest determined by principal component analysis (PCA) would improve the estimation. Next, UEI was performed on five human cadaver feet mounted in a materials testing system (MTS) while the PTT was attached to a force actuator. A portable ultrasound scanner collected 2D data during loading cycles. Young's modulus was calculated from the strain, loading force and cross sectional area of the PTT. Average Young's modulus for the five tendons was (0.45+/-0.16GPa) using UEI. This was consistent with simultaneous measurements made by the MTS across the whole tendon (0.52+/-0.18GPa). We also calculated the scaling factor (0.12+/-0.01) between the load on the PTT and the inversion force at the forefoot, a measurable quantity in vivo. This study suggests that UEI could be a reliable in vivo technique for estimating the mechanical properties of the human PTT. Finally, we built a custom ankle inversion platform for in vivo imaging of human subjects (eight healthy volunteers and nine advanced PTTD patients). We found non-linear elastic properties of the PTTD, which could be quantified by the slope between the elastic modulus (E) and the inversion force (F). This slope (DeltaE/DeltaF), or Non-linear Elasticity Parameter (NEP), was significantly different for the two groups: 0.16+/-0.20 MPa/N for healthy tendons and 0.45+/-0.43 MPa/N for PTTD tendons. A receiver operating characteristic (ROC) curve revealed an area under the curve (AUC) of 0.83+/-0.07, which indicated that the classifier system is valid. In summary, the acoustic modeling, cadaveric studies, and in vivo experiments together demonstrated that UEI accurately quantifies tendon mechanical properties. As a valuable clinical tool, UEI also has the potential to help guide treatment decisions for advanced PTTD and other tendinopathies.

  12. Nickel-titanium wire in circumferential suture of a flexor tendon repair: a comparison to polypropylene.

    PubMed

    Karjalainen, T; He, M; Chong, A K S; Lim, A Y T; Ryhanen, J

    2010-07-01

    Nickel-titanium (NiTi) has been proposed as an alternative material for flexor tendon core suture. To our knowledge, its suitability as a circumferential suture of flexor tendon repair has not been investigated before. The purpose of this ex vivo study was to investigate the biomechanical properties of NiTi circumferential repairs and to compare them with commonly used polypropylene. Forty porcine flexor tendons were cut and repaired by simple running or interlocking mattress technique using 100 microm NiTi wire or 6-0 polypropylene. The NiTi circumferential repairs showed superior stiffness, gap resistance, and load to failure when compared to polypropylene repairs with both techniques. Nickel-titanium wire seems to be a potential material for circumferential repair of flexor tendons. Copyright 2010 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  13. Influence of cyclic hydrostatic pressure on fibrocartilaginous metaplasia of achilles tendon fibroblasts.

    PubMed

    Shim, J W; Elder, S H

    2006-11-01

    The goal of this study was to demonstrate whether cyclically imposed hydrostatic pressure, compressive in nature, could induce fibrocartilaginous metaplasia in a purely tendinous cell source in vitro. The effect of short-duration cyclic hydrostatic pressure on tendon fibroblasts (tenocytes) expanded from rat Achilles tendon was studied. Total RNA was isolated either immediately after loading or 24 h later. The mRNA expression of tendon and cartilage specific markers - Collagen types I and II, Sox9, and Aggrecan was quantified by real-time reverse transcription polymerase chain reaction over multiple biological samples (n=6). For immediately isolated RNA samples, there were statistically significant increases in mRNA expression of Aggrecan and Collagen type II, while Collagen type I significantly decreased. Noticeably, for RNA samples isolated 24 h later, there were further increases in mRNA expression of Aggrecan and Collagen type II, whereas Collagen type I increased roughly three-fold relative to the non-loaded control. These findings support the hypothesis that cyclic hydrostatic pressurization can induce fibrocartilaginous metaplasia in tenocytes by upregulation of cartilaginous gene expression. Also, it was demonstrated that changes in mRNA expression as a result of single 2 h pressurization persist even up to 24 h.

  14. Regional stiffening with aging in tibialis anterior tendons of mice occurs independent of changes in collagen fibril morphology

    PubMed Central

    Wood, Lauren K.; Arruda, Ellen M.

    2011-01-01

    The incidence of tendon degeneration and rupture increases with advancing age. The mechanisms underlying this increased risk remain unknown but may arise because of age-related changes in tendon mechanical properties and structure. Our purpose was to determine the effect of aging on tendon mechanical properties and collagen fibril morphology. Regional mechanical properties and collagen fibril characteristics were determined along the length of tibialis anterior (TA) tendons from adult (8- to 12-mo-old) and old (28- to 30-mo-old) mice. Tangent modulus of all regions along the tendons increased in old age, but the increase was substantially greater in the proximal region adjacent to the muscle than in the rest of the tendon. Overall end-to-end modulus increased with old age at maximum tendon strain (799 ± 157 vs. 1,419 ± 91 MPa) and at physiologically relevant strain (377 ± 137 vs. 798 ± 104 MPa). Despite the dramatic changes in tendon mechanical properties from adulthood to old age, collagen fibril morphology and packing fraction remained relatively constant in all tendon regions examined. Since tendon properties are influenced by their external loading environment, we also examined the effect of aging on TA muscle contractile properties. Maximum isometric force did not differ between the age groups. We conclude that TA tendons stiffen in a region-dependent manner throughout the life span, but the changes in mechanical properties are not accompanied by corresponding changes in collagen fibril morphology or force-generating capacity of the TA muscle. PMID:21737825

  15. Effects of training on collagen fibril populations in the suspensory ligament and deep digital flexor tendon of young thoroughbreds.

    PubMed

    Patterson-Kane, J C; Firth, E C; Parry, D A; Wilson, A M; Goodship, A E

    1998-01-01

    To determine the effect of a specific galloping exercise regimen on collagen fibril mass-average diameters (MAD) in the deep digital flexor tendon (DDFT) and suspensory ligament (SL) of young Thoroughbreds. 12 Thoroughbred fillies, 21 +/- 1 (mean +/- SD) months old. 6 horses underwent a specific 18-month treadmill training program involving galloping exercise. The remaining 6 horses served as controls, undertaking low-volume walking exercise over the same period. Sections were excised from the midpoint of the DDFT and SL, and small strips were dissected from central and peripheral locations for each structure. Fibril diameters were measured from micrographs of transverse ultrathin sections, using a computerized image analysis program. An MAD value was calculated for the central and peripheral regions of the DDFT and SL for each horse. Values for both regions were compared between exercised and control horses. The MAD did not change significantly with exercise for either the DDFT or the SL. Loading of the DDFT as a result of this exercise regimen was not sufficient to stimulate collagen fibril hypertrophy, in keeping with current data that indicate this tendon, compared with the SL and superficial digital flexor tendon (SDFT), is subjected to low loads. Microtrauma, in terms of reduction in fibril MAD, may have occurred in the SL at a site different from that sampled. Another possibility is that, between the trot and the gallop, loading of the SL does not increase to the same extent as that of the SDFT.

  16. Increased Risk of Revision After Anterior Cruciate Ligament Reconstruction With Bone-Patellar Tendon-Bone Allografts Compared With Autografts.

    PubMed

    Maletis, Gregory B; Chen, Jason; Inacio, Maria C S; Love, Rebecca M; Funahashi, Tadashi T

    2017-05-01

    The use of allograft tissue for anterior cruciate ligament reconstruction (ACLR) remains controversial. To compare the risk of aseptic revision between bone-patellar tendon-bone (BPTB) autografts and BPTB allografts. Cohort study; Level of evidence, 2. A retrospective cohort study of prospectively collected data was conducted using the Kaiser Permanente ACLR Registry. A cohort of patients who underwent primary unilateral ACLR with BPTB autografts and BPTB allografts was identified. Aseptic revision was the endpoint. The type of graft and allograft processing method (nonprocessed, <1.8-Mrad, and ≥1.8-Mrad irradiation) were the exposures of interest evaluated. Age (≤21 and ≥22 years) was evaluated as an effect modifier. Analyses were adjusted for age, sex, and race. Kaplan-Meier curves and Cox proportional hazards models were employed. Hazard ratios (HRs) and 95% CIs are provided. The BPTB cohort consisted of 5586 patients: 3783 (67.7%) were male, 2359 (42.2%) were white, 1029 (18.4%) had allografts (nonprocessed: 155; <1.8 Mrad: 525; ≥1.8 Mrad: 288), and 4557 (81.6%) had autografts. The median age was 34.9 years (interquartile range [IQR], 25.4-44.0) for allograft cases and 22.0 years (IQR, 17.6-30.0) for autograft cases. The estimated cumulative revision rate at 2 years was 4.1% (95% CI, 2.9%-5.9%) for allografts and 1.7% (95% CI, 1.3%-2.2%) for autografts. BPTB allografts had a significantly higher adjusted risk of revision than BPTB autografts (HR, 4.54; 95% CI, 3.03-6.79; P < .001). This higher risk of revision was consistent with all allograft processing methods when compared with autografts and was also consistently higher in patients with allografts regardless of age. When BPTB allograft tissue was used for ACLR, an overall 4.54 times adjusted higher risk of revision was observed compared with surgery performed with a BPTB autograft. Whether the tissue was irradiated with either high- or low-dose radiation, chemically processed, or not processed at all made little difference in the risk of revision. The differences in the revision risk were also consistent in younger and older patients. Surgeons and patients should be aware of the increased risk of revision when a BPTB allograft is used for ACLR.

  17. Surgical Management of Simultaneous Anterior Cruciate Ligament and Patellar Tendon Ruptures: A Systematic Review.

    PubMed

    Meheux, Carlos J; Jack, Robert A; McCulloch, Patrick C; Lintner, David M; Harris, Joshua D

    2017-12-28

    This study performs a systematic review to determine (1) if a significant difference exists in return to preinjury activity level between one- and two-stage treatment of combined anterior cruciate ligament (ACL) and patellar tendon (PT) tears; and (2) if a significant difference exists in the number of postoperative complications between the two differing surgical treatment approaches. A systematic review was performed using Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) guidelines and registered on PROSPERO. MEDLINE, Cochrane Central Register of Controlled Trials, SCOPUS, and Sport Discus were searched for English language level I-IV evidence studies on either one- (simultaneous) or two-stage (sequential) surgical treatment of simultaneously sustained ipsilateral ACL and PT tears. The approach to initial evaluation, diagnosis, treatment, and outcomes were qualitatively analyzed. Methodological quality assessment of all included studies was completed using the Methodological Index for Non-randomized Studies (MINORS). The Grading of Recommendations, Assessment, Development, and Evaluation (GRADE) tool was used to assess quality of evidence and provide strength of recommendation. Statistical analyses were done using Fischer's exact test. Eleven articles (18 patients; 83% males; mean age, 31.1 ± 10.1 years; mean follow-up, 2.2 ± 1.7 years; and mean MINORS 7.8/16) were analyzed. Eight patients had a one-stage procedure (primary PT repair and ACL reconstruction), and 10 patients underwent a two-stage procedure (primary PT repair first followed by ACL reconstruction) with mean 28 ± 45.7 weeks (5 weeks-3 years) between surgeries. The rate for return to preinjury activity level after surgery was not significantly different between one- (88%) and two-stage (100%) ( p  = 0.444). There was a significantly higher complication rate ( p  = 0.023) in the one-stage (stiffness, instability, and patella baja) versus two-stage surgery (no complications). There was no significant difference in return to preinjury activity level between one- and two-stage PT repair and ACL reconstruction. However, the one-stage combined surgery had a significantly higher complication rate compared with two-stage surgery. The level of evidence is IV. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  18. Sporicidal efficacy of genipin: a potential theoretical alternative for biomaterial and tissue graft sterilization.

    PubMed

    Reich, Michael S; Akkus, Ozan

    2013-09-01

    Terminal sterilization of musculoskeletal allografts by gamma radiation minimizes the risk of disease transmission but impairs allograft mechanical properties. Commonly employed crosslinking agents can sterilize tissues without affecting mechanical properties adversely; however, these agents are toxic. Genipin is reported to be a benign crosslinking agent that strengthens mechanical properties of tissues; however, the antimicrobial capacity of genipin is largely unknown. The present study's aims were: (1) to assess the sporicidal potential of genipin, (2) to improve antimicrobial capacity by changing chemical and physical treatment conditions. To establish genipin's sterilization potential Bacillus subtilis var. niger spore strips were treated with 0-10% genipin in PBS or in 1:1 DMSO:PBS up to 72 h at room temperature (RT). Sterilizing doses and concentrations of genipin were used to treat B. pumilus and Geobacillus stearothermophilus spores to assess broader spectrum sporicidal activity of genipin. Scanning electron microscopy (SEM) was performed to evaluate gross morphological changes after genipin treatment. Optimal sterilization conditions were determined by evaluating the effects of temperature (RT-50 °C), DMSO:PBS ratio (0:100-100:0), and treatment duration (24-72 h) on B. subtilis. Genipin penetration of full thickness bovine patellar tendon and cortical bone specimens was observed to assess the feasibility of the agent for treating grafts. Initial studies showed that after 72 h of treatment at RT with 0.63-10% genipin/DMSO:PBS B. subtilis spore strips were sterilized; 0.63% genipin/PBS did not sterilize spore strips at 72 h at RT. Genipin doses and concentrations that sterilized B. subtilis spore strips sterilized B. pumilus and G. stearothermophilus spore strips. SEM revealed no gross morphological differences between untreated and treated spores. Treatment optimization resulted in sterilization within 24 h with 100% PBS, and DMSO facilitated sporicidal activity. Genipin penetrated full thickness patellar tendon specimens and 3.72 ± 0.58 mm in cortical bone specimens. Genipin sterilizes B. subtilis, B. pumilus, and G. stearothermophilus spore strips. It penetrates soft and hard tissues at doses previously shown to be non-toxic and to improve mechanical strength in collagen-rich soft tissues. Further studies are indicated to assess genipin's effects on the mechanical properties of genipin-sterilized grafts, the ability of genipin to eradicate infectious species other than spores, and to assess whether sterilant activity persists after penetrating tissues and biomaterials.

  19. Incidence of Second Anterior Cruciate Ligament Tears and Identification of Associated Risk Factors From 2001 to 2010 Using a Geographic Database

    PubMed Central

    Schilaty, Nathan D.; Nagelli, Christopher; Bates, Nathaniel A.; Sanders, Thomas L.; Krych, Aaron J.; Stuart, Michael J.; Hewett, Timothy E.

    2017-01-01

    Background: The reported rate of second anterior cruciate ligament (ACL) injuries (20%-30%), including graft failure and contralateral ACL tears, after ACL reconstruction (ACLR) or nonoperative therapy indicates that multiple factors may predispose patients to subsequent ACL injuries. Purpose: To determine the incidence of second ACL injuries in a population-based cohort over a 10-year observation period (2001-2010) and to identify factors that contribute to the risk of second injuries. Study Design: Descriptive epidemiological study. Methods: International Classification of Diseases, 9th Revision (ICD-9) codes relevant to the diagnosis of an ACL tear and the procedure code for ACLR were utilized to search the Rochester Epidemiology Project, a multidisciplinary county database, between the years of 2001 and 2010. The complete medical records for all cases were reviewed to confirm diagnosis and treatment details. A total of 914 unique patients with 1019 acute, isolated ACL tears were identified. These patients were stratified by primary and secondary tears, sex, age, activity level, side of injury, sex × side of injury, and graft type of reconstruction. Results: Second ACL tears were recorded in 141 (13.8%) of the 914 patients diagnosed with an ACL tear in Olmsted County, Minnesota, USA, from 2001 to 2010; 50.4% of these occurred in the contralateral knee. A noncontact mechanism was responsible for 76.4% of all ACL injuries. A second ACL injury was influenced by factors of sex × age group, treatment type × age group, and treatment type × activity level. Nonparametric analysis of graft disruption × graft type demonstrated that a higher prevalence of second ACL tears occurred with allografts compared with hamstring autografts (P = .0054) and patellar tendon autografts (P = .0001). Conclusion: The incidence of second ACL tears in this population-based cohort was 13.8%, and half occurred to the ACL of the contralateral knee. Statistically, second ACL injuries differed by sex, occurring in female patients younger than 25 years and male patients aged 26 to 45 years. Allografts continued to be associated with a greater risk of second ACL injuries compared with hamstring and patellar tendon autografts. Nonoperative treatment carried more risk of contralateral tears than ACLR. PMID:28840155

  20. Twenty-Year Outcome of a Longitudinal Prospective Evaluation of Isolated Endoscopic Anterior Cruciate Ligament Reconstruction With Patellar Tendon or Hamstring Autograft.

    PubMed

    Thompson, Simon Michael; Salmon, Lucy J; Waller, Alison; Linklater, James; Roe, Justin P; Pinczewski, Leo A

    2016-12-01

    Long-term prospective studies of isolated endoscopic anterior cruciate ligament (ACL) reconstruction are limited and may include confounding factors. This study aimed to compare the outcomes of isolated ACL reconstruction using the patellar tendon (PT) autograft and the hamstring (HT) autograft in 180 patients over 20 years. Cohort study; Level of evidence, 2. A total of 180 participants undergoing isolated ACL reconstruction between 1993 and 1994 were prospectively recruited. Evaluation was performed at 1, 2, 5, 7, 10, 15, and 20 years after surgery and included the International Knee Documentation Committee (IKDC) knee ligament evaluation with radiographic evaluation, KT-1000 arthrometer side-to-side difference, and subjective scores. Over 20 years, there were 16 patients (18%) and 9 patients (10%) with an ACL graft rupture in the HT and PT groups, respectively (P = .13). ACL graft rupture was associated with male sex (odds ratio [OR], 3.9; P = .007), nonideal tunnel position (OR, 3.6; P = .019), and age <18 years at the time of surgery (OR, 4.6; P = .003). The odds of a contralateral ACL rupture were increased in patients with the PT graft compared with patients with the HT graft (OR, 2.2; P = .02) and those aged <18 years at the time of surgery (OR, 3.4; P = .001). The mean IKDC scores at 20-year follow-up were 86 and 89 for the PT and HT groups, respectively (P = .18). At 20 years, 53% and 57% of the PT and HT groups participated in strenuous or very strenuous activities (P = .55), kneeling pain was present in 63% and 20% of the PT and HT groups (P = .018), and radiographic osteoarthritic change was found in 61% and 41% of the PT and HT groups (P = .008), respectively. Compared with patients who received the HT graft, patients who received the PT graft had significantly worse outcomes with regard to radiologically detectable osteoarthritis, kneeling pain, and contralateral ACL injury. At 20-year follow-up, both HT and PT autografts continued to provide good subjective outcomes and objective stability. However, further ACL injury is common, particularly in male individuals, younger patients, and those with tunnel malposition. © 2016 The Author(s).

  1. Return to Play and Patient Satisfaction After ACL Reconstruction: Study with Minimum 2-Year Follow-up.

    PubMed

    Nwachukwu, Benedict U; Voleti, Pramod B; Berkanish, Patricia; Chang, Brenda; Cohn, Matthew R; Williams, Riley J; Allen, Answorth A

    2017-05-03

    Return to play and patient satisfaction after anterior cruciate ligament reconstruction (ACLR) have been inconsistently studied. The purposes of this study were to (1) investigate rates and predictors of return to play after ACLR, (2) evaluate patient satisfaction after ACLR, and (3) analyze the relationship between return to play and satisfaction with the result of ACLR. Eligible patients were active athletes included in an institutional ACL registry who had undergone ACLR and had been followed for a minimum of 2 years. A questionnaire was administered to elicit information regarding factors associated with return to play, sports performance, reinjury, and overall patient satisfaction. The Wilcoxon-Mann-Whitney U test was used to compare return to play with patient satisfaction. Multivariable logistic regression was used to identify demographic, sports, and clinical factors associated with return to play. Two hundred and thirty-two patients with a mean age of 26.7 years (standard deviation [SD] = 12.5 years) who had been followed for a mean of 3.7 years were enrolled. Of 231 patients who responded to the return-to-play question, 201 (87.0%) had returned to play, at a mean of 10.1 months; of 175 athletes eligible to return to their prior level of competition, 89.1% had done so. Overall satisfaction was high: 85.4% were very satisfied with the outcome and 98.1% stated that they would have surgery again. Patients were more likely to respond "very satisfied" if they had returned to play (p < 0.001). Use of a patellar tendon autograft (odds ratio [OR] = 5.63, 95% confidence interval [CI] = 1.32 to 25.76) increased the chance of returning to play whereas playing soccer (OR = 0.23, 95% CI = 0.08 to 0.66) or lacrosse (OR = 0.24, 95% CI = 0.06 to 0.99) preoperatively decreased the likelihood of returning to play. The rates of return to play and patient satisfaction are high after ACLR in active athletes. The use of patellar tendon autograft increased the likelihood of returning to play whereas preinjury participation in soccer and lacrosse decreased these odds. Additionally, patients who returned to play were more likely to be very satisfied with the result of the ACLR. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  2. Return to Sports and Subsequent Injury Rates After Revision Anterior Cruciate Ligament Reconstruction With Patellar Tendon Autograft.

    PubMed

    Shelbourne, K Donald; Benner, Rodney W; Gray, Tinker

    2014-06-01

    The return-to-sport and reinjury rates are not well defined after revision anterior cruciate ligament (ACL) reconstruction. School-age athletes would have a higher rate of return to sports and reinjury to either knee after revision ACL surgery compared with college or recreational athletes. Cohort study; Level of evidence, 2. Patients were prospectively studied after revision ACL reconstruction with bone-patellar tendon-bone (BPTB) autograft. Participants were grouped by competitive sport levels of school age (mean age, 16.6 ± 0.9 years; n = 84), college (19.6 ± 1.2 years; n = 58), or recreational adult (27.6 ± 4.1 years; n = 117). An activity survey was used to determine the specific sport and sport level patients participated in before and after surgery. The International Knee Documentation Committee (IKDC) knee survey and Cincinnati Knee Rating System (CKRS) survey responses were also obtained. The rate of return to the same sport at the same level was 62 of 84 school-age athletes (74%), 43 of 58 college athletes (74%), and 73 of 117 recreational athletes (62%) (P = .1065). The number of patients who had a subsequent ACL graft tear rate after revision surgery was 2 of 84 (2.3%) in the high school group, 3 of 58 (5.1%) in the college group, and 4 of 117 (3.4%) in the recreational group (P = .6706). The number of patients who had a subsequent ACL tear in the contralateral knee was 1 of 84 (1.1%) in the school-age group, 1 of 58 (1.7%) in the college group, and 2 of 117 (1.7%) in the recreational group (P = .9501). At 2 years postoperatively, the mean IKDC subjective total score was 86.1 ± 11.7 points and the mean CKRS total score was 89.7 ± 11.1 points. Revision ACL reconstruction with BPTB autograft and perioperative rehabilitation allowed high school and college athletes to return to sports at the preinjury level at a rate of 74%; the return rate for recreational-level adults was 62%. Reinjury rates in the first 5 years after revision surgery ranged from 2% to 5%, which is lower than what has been reported for young competitive athletes after primary surgery. © 2014 The Author(s).

  3. Autologous conditioned plasma as therapy of tendon and ligament lesions in seven horses

    PubMed Central

    Georg, Rindermann; Maria, Cislakova; Gisela, Arndt

    2010-01-01

    This case report describes the intralesional application of autologous conditioned plasma (ACP) in seven horses as treatment of severe tendinitis of the superficial digital flexor tendon, deep digital flexor tendon, or desmitis of the inferior check ligament. Follow-up data of the horses revealed a positive outcome in 10 to 13 months post injury. All horses treated with ACP were either performing in their previous work-load or were back in full training. Further studies with long-term follow-up will have to be performed to support these clinical intermediate-term observations. PMID:20458161

  4. Biochemical, histologic, and biomechanical characterization of native and decellularized flexor tendon specimens harvested from the pelvic limbs of orthopedically normal dogs.

    PubMed

    Balogh, Daniel G; Biskup, Jeffery J; O'Sullivan, M Gerard; Scott, Ruth M; Groschen, Donna; Evans, Richard B; Conzemius, Michael G

    2016-04-01

    To evaluate the biochemical and biomechanical properties of native and decellularized superficial digital flexor tendons (SDFTs) and deep digital flexor tendons (DDFTs) harvested from the pelvic limbs of orthopedically normal dogs. 22 commercially supplied tendon specimens (10 SDFT and 12 DDFT) harvested from the pelvic limbs of 13 canine cadavers. DNA, glycosaminoglycan, collagen, and protein content were measured to biochemically compare native and decellularized SDFT and DDFT specimens. Mechanical testing was performed on 4 groups consisting of native tendons (5 SDFTs and 6 DDFTs) and decellularized tendons (5 SDFTs and 6 DDFTs). All tendons were preconditioned, and tension was applied to failure at 0.5 mm/s. Failure mode was video recorded for each tendon. Load-deformation and stress-strain curves were generated; calculations were performed to determine the Young modulus and stiffness. Biochemical and biomechanical data were statistically compared by use of the Wilcoxon rank sum test. Decellularized SDFT and DDFT specimens had significantly less DNA content than did native tendons. No significant differences were identified between native and decellularized specimens with respect to glycosaminoglycan, collagen, or protein content. Biomechanical comparison yielded no significant intra- or intergroup differences. All DDFT constructs failed at the tendon-clamp interface, whereas nearly half (4/10) of the SDFT constructs failed at midsubstance. Decellularized commercial canine SDFT and DDFT specimens had similar biomechanical properties, compared with each other and with native tendons. The decellularization process significantly decreased DNA content while minimizing loss of extracellular matrix components. Decellularized canine flexor tendons may provide suitable, biocompatible graft scaffolds for bioengineering applications such as tendon or ligament repair.

  5. Early stage fatigue damage occurs in bovine tendon fascicles in the absence of changes in mechanics at either the gross or micro-structural level

    PubMed Central

    Shepherd, Jennifer H.; Riley, Graham P.; Screen, Hazel R.C.

    2014-01-01

    Many tendon injuries are believed to result from repetitive motion or overuse, leading to the accumulation of micro-damage over time. In vitro fatigue loading can be used to characterise damage during repeated use and investigate how this may relate to the aetiology of tendinopathy. This study considered the effect of fatigue loading on fascicles from two functionally distinct bovine tendons: the digital extensor and deep digital flexor. Micro-scale extension mechanisms were investigated in fascicles before or after a period of cyclic creep loading, comparing two different measurement techniques – the displacement of a photo-bleached grid and the use of nuclei as fiducial markers. Whilst visual damage was clearly identified after only 300 cycles of creep loading, these visual changes did not affect either gross fascicle mechanics or fascicle microstructural extension mechanisms over the 900 fatigue cycles investigated. However, significantly greater fibre sliding was measured when observing grid deformation rather than the analysis of nuclei movement. Measurement of microstructural extension with both techniques was localised and this may explain the absence of change in microstructural deformation in response to fatigue loading. Alternatively, the data may demonstrate that fascicles can withstand a degree of matrix disruption with no impact on mechanics. Whilst use of a photo-bleached grid to directly measure the collagen is the best indicator of matrix deformation, nuclei tracking may provide a better measure of the strain perceived directly by the cells. PMID:25001495

  6. Effect of diet-induced vitamin D deficiency on rotator cuff healing in a rat model.

    PubMed

    Angeline, Michael E; Ma, Richard; Pascual-Garrido, Cecilia; Voigt, Clifford; Deng, Xiang Hua; Warren, Russell F; Rodeo, Scott A

    2014-01-01

    Few studies have considered hormonal influences, particularly vitamin D, on healing. Vitamin D deficiency would have a negative effect on the structure of the healing tendon-bone interface in a rat model and would result in decreased tendon attachment strength. Controlled laboratory study. Vitamin D deficiency was induced in 28 male Sprague-Dawley rats using a specialized vitamin D-deficient diet and ultraviolet light restriction. Serum levels of vitamin D were measured after 6 weeks. These vitamin D-deficient animals (experimental group) plus 32 rats with normal vitamin D levels (controls) underwent unilateral detachment of the right supraspinatus tendon from the greater tuberosity of the humerus, followed by immediate repair using bone tunnel suture fixation. The animals were sacrificed at 2- and 4-week intervals after surgery for biomechanical analysis. A paired t test was used to compare serum vitamin D levels at day 0 and at 6 weeks. A nonparametric Mann-Whitney U test was used to compare load-to-failure and stiffness values between the experimental group and controls. Bone density and new bone formation at the tendon insertion site on the greater tuberosity were assessed with micro-computed tomography (CT). The organization of collagen tissue, new bone formation, vascularity at the tendon-bone interface, fibrocartilage at the tendon-bone interface, and collagen fiber continuity between the tendon and bone tissue were evaluated with safranin O and picrosirius red staining. Blood draws confirmed vitamin D deficiency at 6 weeks compared with time zero/baseline for rats in the experimental group (10.9 ng/mL vs 6.5 ng/mL, respectively; P < .001). Biomechanical testing demonstrated a significant decrease in load to failure in the experimental group compared with controls at 2 weeks (5.8 ± 2.0 N vs 10.5 ± 4.4 N, respectively; P < .006). There was no difference in stiffness at 2 weeks between the control and experimental groups. At 4 weeks, there was no significant difference in load to failure or stiffness between the control and experimental groups. Histological analysis showed less bone formation and less collagen fiber organization in the vitamin D-deficient specimens at 4 weeks as compared with controls. Micro-CT analysis showed no significant difference between groups for total mineral density and bone volume fraction of cortical, whole, or trabecular bone at 4 weeks. The biomechanical and histological data from this study suggest that low vitamin D levels may negatively affect early healing at the rotator cuff repair site. It is estimated that 1 billion people worldwide are vitamin D deficient. In the deficient state, acutely injured rotator cuffs may have a reduced ability for tendon healing. Further studies are needed to determine the exact mechanism by which vitamin D affects tendon healing and whether vitamin D supplementation can improve rotator cuff tendon healing and reduce the incidence of retears.

  7. Fatigue loading of tendon

    PubMed Central

    Shepherd, Jennifer H; Screen, Hazel R C

    2013-01-01

    Tendon injuries, often called tendinopathies, are debilitating and painful conditions, generally considered to develop as a result of tendon overuse. The aetiology of tendinopathy remains poorly understood, and whilst tendon biopsies have provided some information concerning tendon appearance in late-stage disease, there is still little information concerning the mechanical and cellular events associated with disease initiation and progression. Investigating this in situ is challenging, and numerous models have been developed to investigate how overuse may generate tendon fatigue damage and how this may relate to tendinopathy conditions. This article aims to review these models and our current understanding of tendon fatigue damage. We review the strengths and limitations of different methodologies for characterizing tendon fatigue, considering in vitro methods that adopt both viable and non-viable samples, as well as the range of different in vivo approaches. By comparing data across model systems, we review the current understanding of fatigue damage development. Additionally, we compare these findings with data from tendinopathic tissue biopsies to provide some insights into how these models may relate to the aetiology of tendinopathy. Fatigue-induced damage consistently highlights the same microstructural, biological and mechanical changes to the tendon across all model systems and also correlates well with the findings from tendinopathic biopsy tissue. The multiple testing routes support matrix damage as an important contributor to tendinopathic conditions, but cellular responses to fatigue appear complex and often contradictory. PMID:23837793

  8. Clinical and biomechanical assessment of patella resurfacing in total knee arthroplasty.

    PubMed

    Berti, Lisa; Benedetti, Maria Grazia; Ensini, Andrea; Catani, Fabio; Giannini, Sandro

    2006-07-01

    Currently there is a limited understanding of the factors influencing range of motion by comparing patellar resurfacing vs non-resurfacing in total knee arthroplasty during activities of daily living. A recent meta-analysis of patellar replacement confirms better outcome with patella resurfacing; however, the result can be influenced by many other factors, such as: component design, surgeon experience, and technical aspects of the surgery. This study compares the biomechanics of the knee in patients after total knee arthroplasty with and without patellar resurfacing during stair climbing. Forty-seven patients with total knee arthroplasty were assessed at the mean follow-up of 24 months. In all of them a posterior stabilised fixed bearing prosthesis (Optetrak PS, Exactech) was implanted. Twenty-six patients were treated without patellar resurfacing and 21 with patellar resurfacing. Clinical evaluations were performed using the International Knee Society and the Hospital for Special Surgery scores. Ten patients with patellar resurfacing and 10 patients without patellar resurfacing were also studied with motion analysis during stair climbing; 10 healthy subjects were studied for statistical comparison. Clinical passive knee flexion, International Knee Society Function and Hospital for Special Surgery scores were significantly higher in the patellar resurfacing group. During stair climbing, active knee joint range of motion during the stance phase was greater in patients with patellar resurfacing. The maximum adduction moment was significantly higher in the group without patellar resurfacing. Patients with patellar resurfacing demonstrated better clinical scores, and kinematic and kinetic data while ascending stairs.

  9. Negative pressure wound therapy for the treatment of infected wounds with exposed knee joint after patellar fracture.

    PubMed

    Lee, Sang Yang; Niikura, Takahiro; Miwa, Masahiko; Sakai, Yoshitada; Oe, Keisuke; Fukazawa, Takahiro; Kawakami, Yohei; Kurosaka, Masahiro

    2011-06-14

    Treatment of soft tissue defects with exposed bones and joints, resulting from trauma, infection, and surgical complications, represents a major challenge. The introduction of negative pressure wound therapy has changed many wound management practices. Negative pressure wound therapy has recently been used in the orthopedic field for management of traumatic or open wounds with exposed bone, nerve, tendon, and orthopedic implants. This article describes a case of a patient with a large soft tissue defect and exposed knee joint, in which negative pressure wound therapy markedly improved wound healing. A 50-year-old man presented with an ulceration of his left knee with exposed joint, caused by severe wound infections after open reduction and internal fixation of a patellar fracture. After 20 days of negative pressure wound therapy, a granulated wound bed covered the exposed bones and joint.To our knowledge, this is the first report of negative pressure wound therapy used in a patient with a large soft tissue defect with exposed knee joint. Despite the chronic wound secondary to infection, healing was achieved through the use of the negative pressure wound therapy, thus promoting granulation tissue formation and closing the joint. We suggest negative pressure wound therapy as an alternative option for patients with lower limb wounds containing exposed bones and joints when free flap transfer is contraindicated. Our result added to the growing evidence that negative pressure wound therapy is a useful adjunctive treatment for open wounds around the knee joint. Copyright 2011, SLACK Incorporated.

  10. Construction Condition and Damage Monitoring of Post-Tensioned PSC Girders Using Embedded Sensors.

    PubMed

    Shin, Kyung-Joon; Lee, Seong-Cheol; Kim, Yun Yong; Kim, Jae-Min; Park, Seunghee; Lee, Hwanwoo

    2017-08-10

    The potential for monitoring the construction of post-tensioned concrete beams and detecting damage to the beams under loading conditions was investigated through an experimental program. First, embedded sensors were investigated that could measure pre-stress from the fabrication process to a failure condition. Four types of sensors were installed on a steel frame, and the applicability and the accuracy of these sensors were tested while pre-stress was applied to a tendon in the steel frame. As a result, a tri-sensor loading plate and a Fiber Bragg Grating (FBG) sensor were selected as possible candidates. With those sensors, two pre-stressed concrete flexural beams were fabricated and tested. The pre-stress of the tendons was monitored during the construction and loading processes. Through the test, it was proven that the variation in thepre-stress had been successfully monitored throughout the construction process. The losses of pre-stress that occurred during a jacking and storage process, even those which occurred inside the concrete, were measured successfully. The results of the loading test showed that tendon stress and strain within the pure span significantly increased, while the stress in areas near the anchors was almost constant. These results prove that FBG sensors installed in a middle section can be used to monitor the strain within, and the damage to pre-stressed concrete beams.

  11. Construction Condition and Damage Monitoring of Post-Tensioned PSC Girders Using Embedded Sensors

    PubMed Central

    Shin, Kyung-Joon; Lee, Seong-Cheol; Kim, Yun Yong; Kim, Jae-Min; Park, Seunghee; Lee, Hwanwoo

    2017-01-01

    The potential for monitoring the construction of post-tensioned concrete beams and detecting damage to the beams under loading conditions was investigated through an experimental program. First, embedded sensors were investigated that could measure pre-stress from the fabrication process to a failure condition. Four types of sensors were installed on a steel frame, and the applicability and the accuracy of these sensors were tested while pre-stress was applied to a tendon in the steel frame. As a result, a tri-sensor loading plate and a Fiber Bragg Grating (FBG) sensor were selected as possible candidates. With those sensors, two pre-stressed concrete flexural beams were fabricated and tested. The pre-stress of the tendons was monitored during the construction and loading processes. Through the test, it was proven that the variation in thepre-stress had been successfully monitored throughout the construction process. The losses of pre-stress that occurred during a jacking and storage process, even those which occurred inside the concrete, were measured successfully. The results of the loading test showed that tendon stress and strain within the pure span significantly increased, while the stress in areas near the anchors was almost constant. These results prove that FBG sensors installed in a middle section can be used to monitor the strain within, and the damage to pre-stressed concrete beams. PMID:28796156

  12. Single-row versus double-row repair of the distal Achilles tendon: a biomechanical comparison.

    PubMed

    Pilson, Holly; Brown, Philip; Stitzel, Joel; Scott, Aaron

    2012-01-01

    Surgery for recalcitrant insertional Achilles tendinopathy often consists of partial or total release of the insertion site, debridement of the diseased portion of the tendon, calcaneal ostectomy, and reattachment of the Achilles to the calcaneus. Although single-row and double-row techniques exist for repair of the detached Achilles tendon, biomechanical data are lacking to support one technique over the other. Based on data extrapolated from the study of rotator cuff repairs, we hypothesized that a double-row construct would provide superior fixation strength over a single-row repair. Eighteen human cadaveric Achilles tendons (9 matched pairs) with attached calcanei were repaired with single-row or double-row techniques. Specimens were mounted in a servohydraulic materials testing machine, subjected to a preconditioning cycle, and loaded to failure. Failure was defined as suture breakage or pullout, midsubstance tendon rupture, or anchor pullout. Among the failures were 12 suture failures, 5 proximal-row anchor failures, and 1 distal-row anchor failure. No midsubstance tendon ruptures or testing apparatus failures were observed. There were no statistically significant differences in the peak load to failure between the single-row and double-row repairs (p = .46). Similarly, no significant differences were observed with regards to mean energy expenditure to failure (p = .069). The present study demonstrated no biomechanical advantages of the double-row repair over a single-row repair. Despite the lack of a clear biomechanical advantage, there may exist clinical advantages of a double-row repair, such as reduction in knot prominence and restoration of the Achilles footprint. Copyright © 2012 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Biomechanical comparison of four double-row speed-bridging rotator cuff repair techniques with or without medial or lateral row enhancement.

    PubMed

    Pauly, Stephan; Fiebig, David; Kieser, Bettina; Albrecht, Bjoern; Schill, Alexander; Scheibel, Markus

    2011-12-01

    Biomechanical comparison of four different Speed-Bridge configurations with or without medial or lateral row reinforcement. Reinforcement of the knotless Speed-Bridge double-row repair technique with additional medial mattress- or lateral single-stitches was hypothesized to improve biomechanical repair stability at time zero. Controlled laboratory study: In 36 porcine fresh-frozen shoulders, the infraspinatus tendons were dissected and shoulders were randomized to four groups: (1) Speed-Bridge technique with single tendon perforation per anchor (STP); (2) Speed-Bridge technique with double tendon perforation per anchor (DTP); (3) Speed-Bridge technique with medial mattress-stitch reinforcement (MMS); (4) Speed-Bridge technique with lateral single-stitch reinforcement (LSS). All repairs were cyclically loaded from 10-60 N up to 10-200 N (20 N stepwise increase) using a material testing device. Forces at 3 and 5 mm gap formation, mode of failure and maximum load to failure were recorded. The MMS-technique with double tendon perforation showed significantly higher ultimate tensile strength (338.9 ± 90.0 N) than DTP (228.3 ± 99.9 N), LSS (188.9 ± 62.5 N) and STP-technique (122.2 ± 33.8 N). Furthermore, the MMS-technique provided increased maximal force resistance until 3 and 5 mm gap formation (3 mm: 77.8 ± 18.6 N; 5 mm: 113.3 ± 36.1 N) compared with LSS, DTP and STP (P < 0.05 for each 3 and 5 mm gap formation). Failure mode was medial row defect by tendon sawing first, then laterally. No anchor pullout occurred. Double tendon perforation per anchor and additional medial mattress stitches significantly enhance biomechanical construct stability at time zero in this ex vivo model when compared with the all-knotless Speed-Bridge rotator cuff repair.

  14. Isolated patellofemoral arthroplasty reproduces natural patellofemoral joint kinematics when the patella is resurfaced.

    PubMed

    Vandenneucker, Hilde; Labey, Luc; Vander Sloten, Jos; Desloovere, Kaat; Bellemans, Johan

    2016-11-01

    The objectives of this in vitro project were to compare the dynamic three-dimensional patellofemoral kinematics, contact forces, contact areas and contact pressures of a contemporary patellofemoral prosthetic implant with those of the native knee and to measure the influence of patellar resurfacing and patellar thickness. The hypothesis was that these designs are capable to reproduce the natural kinematics but result in higher contact pressures. Six fresh-frozen specimens were tested on a custom-made mechanical knee rig before and after prosthetic trochlear resurfacing, without and with patellar resurfacing in three different patellar thicknesses. Full three-dimensional kinematics were analysed during three different motor tasks, using infrared motion capture cameras and retroflective markers. Patellar contact characteristics were registered using a pressure measuring device. The patellofemoral kinematic behaviour of the patellofemoral arthroplasty was similar to that of the normal knee when the patella was resurfaced, showing only significant (p < 0.0001) changes in patellar flexion. Without patellar resurfacing, significant more patellar flexion, lateral tilt and lateral rotation was noticed. Compared to the normal knee, contact pressures were significantly elevated after isolated trochlear resurfacing. However, the values were more than doubled after patellar resurfacing. Changes in patellar thickness only influenced the antero-posterior patellar position. There was no other influence on the kinematics, and only a limited influence on the contact pressures in the low flexion angles. The investigated design reproduced the normal patellofemoral kinematics acceptable well when the patella was resurfaced. From a kinematic point of view, patellar resurfacing may be advisable. However, the substantially elevated patellar contact pressures remain a point of concern in the decision whether or not to resurface the patella. This study therefore not only adds a new point in the discussion whether or not to resurface the patella, but also supports the claimed advantage that a patellofemoral arthroplasty is capable to reproduce the natural knee kinematics.

  15. [Evaluation of early physiotherapy in patients after surgical treatment of cruciate ligament injury by bone-tendon-bone method].

    PubMed

    Klupiński, Kamil; Krekora, Katarzyna; Woldańska-Okońska, Marta

    2014-01-01

    Anterior cruciate ligament (ACL) is one of the most important structures of the knee joint. It has a stabilizing function and causes sliding movement between the articular surfaces. Most frequently there comes to the anterior cruciate ligament injury during practicing sports such as skiing, football, sports which require sudden turns and those which are associated with jumps for height like basketball and volleyball. The aim of study was to evaluate of the outcomes of complex physiotherapy after reconstruction of anterior cruciate ligament by bone -tendon-bone (BTB) method. The study involved 41 patients, 8 women and 33 men, aged 20 to 45 years, body height 1.60-1.90 cm and body weight 50-100 kg. The patients were divided into two groups. Group I included 26 patients (3 women and 23 men) after arthroscopic ACL reconstruction. Group II--control-group included 15 patients (5 women and 10 men) after ACL injury but not subjected to the ligament reconstruction. The patients from both groups underwent rehabilitation according to the same rehabilitation program suggested by the Medical Magnus Clinic in Lodz, which consisted in performing daily exercises in open and closed kinetic chains. All group I and II patients were examined three times: after surgery (before the start of the rehabilitation), in the sixth week of rehabilitation and 12 weeks afterwards. The clinical examination included: measurement of the range of movement in the knee joint, the measurement of musculoskeletal strength with Lovett scale, knee pain assessment using Visual Analog Scale (VAS), transpatellar anthropometric measurement of the knee joint, linear measurements of the thigh and shin (at two points: 5 and 10 cm above the patellar apex and at two points: 5 and 10 cm below the patellar base). Introduction of early highly specialized physiotherapy has been demonstrated to contribute to the improvement of the rehabilitation outcomes and to the shortening of the therapy. A statistically significant improvement has been obtained in all examined patients after anterior cruciate ligament reconstruction by bone - tendon - bone method at every stage of rehabilitation in relation to the initial values. Early motor physiotherapy has a significant impact on the condition of patients treated both surgically and conservatively. The differences observed between the groups in the range of the measurement of movement in the knee joint, the measurement of musculoskeletal strength, severity of pain in the knee joint, transpatellar anthropometric measurement of the knee joint and linear measurements of the thigh and shin were caused by necessary surgery which leads to the conclusion that the therapeutic rehabilitation should be longer in the investigated group. In this group introduction of physical therapy with analgesic effects is also of importance. Taking into account good results observed in patients from the control group, who were treated conservatively, the possible indications for surgery should be carefully considered.

  16. Modelling approaches for evaluating multiscale tendon mechanics

    PubMed Central

    Fang, Fei; Lake, Spencer P.

    2016-01-01

    Tendon exhibits anisotropic, inhomogeneous and viscoelastic mechanical properties that are determined by its complicated hierarchical structure and varying amounts/organization of different tissue constituents. Although extensive research has been conducted to use modelling approaches to interpret tendon structure–function relationships in combination with experimental data, many issues remain unclear (i.e. the role of minor components such as decorin, aggrecan and elastin), and the integration of mechanical analysis across different length scales has not been well applied to explore stress or strain transfer from macro- to microscale. This review outlines mathematical and computational models that have been used to understand tendon mechanics at different scales of the hierarchical organization. Model representations at the molecular, fibril and tissue levels are discussed, including formulations that follow phenomenological and microstructural approaches (which include evaluations of crimp, helical structure and the interaction between collagen fibrils and proteoglycans). Multiscale modelling approaches incorporating tendon features are suggested to be an advantageous methodology to understand further the physiological mechanical response of tendon and corresponding adaptation of properties owing to unique in vivo loading environments. PMID:26855747

  17. [Clinical study on patellar replacement in total knee arthroplasty].

    PubMed

    Bao, Liang; Gao, Zhihui; Shi, Xiaoqiang; Fang, Xiaomin; Jin, Qunhua

    2013-01-01

    To evaluate the influence of patellar replacement on total knee arthroplasty by comparing with non patellar replacement. Between September 2010 and November 2010, 63 patients (63 knees) with osteoarthritis who met the selection criteria and underwent total knee arthroplasty, were randomly divided into 2 groups: patellar replacement in 32 cases (replacement group), non patellar replacement in 31 cases (non patellar replacement group). There was no significant difference in gender, age, disease duration, osteoarthritis grading, the clinical and functional scores of American Knee Society Score (KSS), the patellar tilt angle, tibiofemoral angle, and patellar ligament ratio between 2 groups (P > 0.05), they were comparable. After 6 weeks, 3, 6, and 12 months of operation, clinical and imaging evaluation methods were used to assessment the effectiveness. Primary healing of incision was obtained in all patients of 2 groups. Deep venous thrombosis occurred in 6 cases of replacement group and in 8 cases of non patellar replacement group. All patients were followed up 12 months. The postoperative incidence of anterior knee pain in replacement group was significantly lower than that in non patellar replacement group (P < 0.05) at 3, 6, and 12 months after operation. No significant difference was found in the postoperative KSS clinical score between 2 groups at each time point (P > 0.05). The joint function score of the replacement group was significantly higher than that of the non patellar replacement group at the other time point (P < 0.05) except the score at 6 weeks and 3 months. Significant difference was found in the patella score between 2 groups at 12 months (P < 0.05), but no significant difference at the other time points (P > 0.05). X-ray film showed no patellar fracture and dislocation, or loosening and breakage of internal fixation. At 12 months after operation, the tibiofemoral angle, the patellar ligament ratio, and the patellar tilt angle showed no significant difference between 2 groups (P > 0.05). Patella replacement can improve knee function score and the patella score, and reduce the incidence of postoperative anterior knee pain.

  18. Eliminating impingement optimizes patellar biomechanics in high knee flexion.

    PubMed

    Tang, Qi-heng; Zhou, Yi-xin; Tang, Jing; Shao, Hong-yi; Wang, Guang-zhi

    2010-08-01

    We investigated the impact of eliminating the impingement between extensor mechanism and tibial insert on patellar tracking and patellar ligament tension in high knee flexion. Six cadaveric specimens were tested on an Oxford-type testing rig. The Genesis II knee system was implanted into each specimen knee with the traditional tibial insert and high-flex insert successively. Compared to traditional insert, the high-flex insert was characterized with a chambered anterior post and a chambered anterior lip which eliminates patella-post and patellar ligament-anterior lip impingements. The patella was tracked with an NDI Optotrak Certus system. The patellar ligament tension was measured using a NKB S-type tension transducer. There was a decrease of resultant patellar translation relative to the femur with statistically significant (P<0.05) at 90 degrees to 150 degrees of knee flexion and a decrease of patellar ligament tension with statistical significance (P<0.05) at 100 degrees, 120 degrees, 130 degrees, and 140 degrees of flexion using high-flex insert compared to traditional insert. Eliminating the impingement between extensor mechanism and implant in high knee flexion altered patellar tracking and reduced patellar ligament tension, which would facilitate high knee flexion.

  19. The effects of the sagittal plane malpositioning of the patella and concomitant quadriceps hypotrophy on the patellofemoral joint: a finite element analysis.

    PubMed

    Aksahin, Ertugrul; Kocadal, Onur; Aktekin, Cem N; Kaya, Defne; Pepe, Murad; Yılmaz, Serdar; Yuksel, H Yalcin; Bicimoglu, Ali

    2016-03-01

    Anterior knee pain is a common symptom after intramedullary nailing in tibia shaft fracture. Moreover, patellofemoral malalignment is also known to be a major reason for anterior knee pain. Patellofemoral malalignment predisposes to increased loading in patellar cartilage. In the previous study, we have demonstrated the quadriceps atrophy and patellofemoral malalignment after intramedullary nailing due to tibia shaft fracture. In this study, our aim was to clarify the effects of quadriceps atrophy and patellofemoral malalignment with the pathologic loading on the joint cartilage. Mesh models of patellofemoral joint were constructed with CT images and integrated with soft tissue components such as menisci and ligaments. Physiological and sagittal tilt models during extension and flexion at 15°, 30° and 60° were created generating eight models. All the models were applied with 137 N force to present the effects of normal loading and 115.7 N force for the simulation of quadriceps atrophy. Different degrees of loading were applied to evaluate the joint contact area and pressure value with the finite element analysis. There was increased patellofemoral contact area in patellar tilt models with respect to normal models. The similar loading patterns were diagnosed in all models at 0° and 15° knee flexion when 137 N force was applied. Higher loading values were obtained at 30° and 60° knee flexions in sagittal tilt models. Furthermore, in the sagittal tilt models, in which the quadriceps atrophy was simulated, the loadings at 30° and 60° knee flexion were higher than in the physiological ones. Sagittal malalignment of the patellofemoral joint is a new concept that results in different loading patterns in the patellofemoral joint biomechanics. This malalignment in sagittal plane leads to increased loading values on the patellofemoral joint at 30° and 60° of the knee flexions. This new concept should be kept in mind during the course of diagnosis and treatment in patients with anterior knee pain. Definition of the exact biomechanical effects of the sagittal tilting will lead to the development of new treatment modalities.

  20. Patellofemoral Arthritis After Lateral Patellar Dislocation: A Matched Population-Based Analysis.

    PubMed

    Sanders, Thomas L; Pareek, Ayoosh; Johnson, Nicholas R; Stuart, Michael J; Dahm, Diane L; Krych, Aaron J

    2017-04-01

    The rate of patellofemoral arthritis after lateral patellar dislocation is unknown. Purpose/Hypothesis: The purpose of this study was to compare the risk of patellofemoral arthritis and knee arthroplasty between patients who experienced a lateral patellar dislocation and matched individuals without a patellar dislocation. Additionally, factors predictive of arthritis after patellar dislocation were examined. The hypothesis was that the rate of arthritis is likely higher among patients who experience a patellar dislocation compared with those who do not. Cohort study; Level of evidence, 3. In this study, 609 patients who had a first-time lateral patellar dislocation between 1990 and 2010 were compared with an age- and sex-matched cohort of patients who did not have a patellar dislocation. Medical records were reviewed to collect information related to the initial injury, recurrent dislocation, treatment, and progression to clinically significant patellofemoral arthritis (defined as symptoms with degenerative changes on patellar sunrise radiographs). Factors associated with arthritis (age, sex, recurrence, osteochondral injury, trochlear dysplasia) were examined. At a mean follow-up of 12.3 ± 6.5 years from initial dislocation, 58 patients (9.5%) in the dislocation cohort were diagnosed with patellofemoral arthritis, corresponding to a cumulative incidence of arthritis of 1.2% at 5 years, 2.7% at 10 years, 8.1% at 15 years, 14.8% at 20 years, and 48.9% at 25 years. In the control cohort, 8 patients (1.3%) were diagnosed with arthritis, corresponding to a cumulative incidence of arthritis of 0% at 5 years, 0% at 10 years, 1.3% at 15 years, 2.9% at 20 years, and 8.3% at 25 years. Therefore, patients who experienced a lateral patellar dislocation had a significantly higher risk of developing arthritis (hazard ratio [HR], 7.8; 95% CI, 3.9-17.6; P < .001) than individuals without a patellar dislocation. However, the risk of knee arthroplasty was similar between groups (HR, 2.8; 95% CI, 0.6-19.7; P = .2). Recurrent patellar dislocations (HR, 4.5; 95% CI, 1.6-12.6), osteochondral injury (HR, 11.3; 95% CI, 5.0-26.6), and trochlear dysplasia (HR, 3.6; 95% CI, 1.3-10.0) were associated with arthritis after patellar dislocation. Patellar dislocation is a significant risk factor for patellofemoral arthritis, as nearly half of patients have symptoms and radiographic changes consistent with arthritis at 25 years after lateral patellar dislocation. Osteochondral injury, recurrent patellar instability, and trochlear dysplasia are associated with the development of arthritis.

Top