Sample records for pathogen decontamination technology-reducing

  1. Agricultural pathogen decontamination technology-reducing the threat of infectious agent spread.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Betty, Rita G.; Bieker, Jill Marie; Tucker, Mark David

    Outbreaks of infectious agricultural diseases, whether natural occurring or introduced intentionally, could have catastrophic impacts on the U.S. economy. Examples of such agricultural pathogens include foot and mouth disease (FMD), avian influenza (AI), citrus canker, wheat and soy rust, etc. Current approaches to mitigate the spread of agricultural pathogens include quarantine, development of vaccines for animal diseases, and development of pathogen resistant crop strains in the case of plant diseases. None of these approaches is rapid, and none address the potential persistence of the pathogen in the environment, which could lead to further spread of the agent and damage aftermore » quarantine is lifted. Pathogen spread in agricultural environments commonly occurs via transfer on agricultural equipment (transportation trailers, tractors, trucks, combines, etc.), having components made from a broad range of materials (galvanized and painted steel, rubber tires, glass and Plexiglas shields, etc), and under conditions of heavy organic load (mud, soil, feces, litter, etc). A key element of stemming the spread of an outbreak is to ensure complete inactivation of the pathogens in the agricultural environment and on the equipment used in those environments. Through the combination of enhanced agricultural pathogen decontamination chemistry and a validated inactivation verification methodology, important technologies for incorporation as components of a robust response capability will be enabled. Because of the potentially devastating economic impact that could result from the spread of infectious agricultural diseases, the proposed capability components will promote critical infrastructure protection and greater border and food supply security. We investigated and developed agricultural pathogen decontamination technologies to reduce the threat of infectious-agent spread, and thus enhance agricultural biosecurity. Specifically, enhanced detergency versions of the patented Sandia decontamination chemistry were developed and tested against a few surrogate pathogens under conditions of relatively heavy organic load. Tests were conducted on surfaces commonly found in agricultural environments. Wide spectrum decontamination efficacy, low corrosivity, and biodegradability issues were addressed in developing an enhanced detergency formulation. A method for rapid assessment of loss of pathogenic activity (inactivation) was also assessed. This enhanced technology will enable rapid assessment of contamination following an intentional event, and will also be extremely useful in routine assessment of agricultural environments. The primary effort during the second year was progress towards a demonstration of both decontamination and viral inactivation technologies of Foot and Mouth virus (FMDv) using the modified SNL chemistry developed through this project. Lab studies using a surrogate virus (bovine enterovirus) were conducted using DF200, modified DF200 chemistry, and decontaminants currently recommended for use in heavily loaded organic, agricultural environments (VirkonS, 10% bleach, sodium hydroxide and citric acid). Tests using actual FMD virus will be performed at the Department of Homeland Security's Plum Island facilities in the fall of 2005. Success and the insight gained from this project will lead to enhanced response capability, which will benefit agencies such as USDA, DHS, DOD, and the agricultural industry.« less

  2. Consensus statement: patient safety, healthcare-associated infections and hospital environmental surfaces.

    PubMed

    Roques, Christine; Al Mousa, Haifaa; Duse, Adriano; Gallagher, Rose; Koburger, Torsten; Lingaas, Egil; Petrosillo, Nicola; Škrlin, Jasenka

    2015-01-01

    Healthcare-associated infections have serious implications for both patients and hospitals. Environmental surface contamination is the key to transmission of nosocomial pathogens. Routine manual cleaning and disinfection eliminates visible soil and reduces environmental bioburden and risk of transmission, but may not address some surface contamination. Automated area decontamination technologies achieve more consistent and pervasive disinfection than manual methods, but it is challenging to demonstrate their efficacy within a randomized trial of the multiple interventions required to reduce healthcare-associated infection rates. Until data from multicenter observational studies are available, automated area decontamination technologies should be an adjunct to manual cleaning and disinfection within a total, multi-layered system and risk-based approach designed to control environmental pathogens and promote patient safety.

  3. Disinfectants used for environmental disinfection and new room decontamination technology.

    PubMed

    Rutala, William A; Weber, David J

    2013-05-01

    Environmental contamination plays an important role in the transmission of several key health care-associated pathogens. Effective and thorough cleaning/disinfecting of the patient environment is essential. Room decontamination units (such as ultraviolet-C and hydrogen peroxide systems) aid in reducing environmental contamination after terminal room cleaning and disinfection. Copyright © 2013 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  4. Generic aspects of the airborne spread of human pathogens indoors and emerging air decontamination technologies.

    PubMed

    Ijaz, M Khalid; Zargar, Bahram; Wright, Kathryn E; Rubino, Joseph R; Sattar, Syed A

    2016-09-02

    Indoor air can be an important vehicle for a variety of human pathogens. This review provides examples of airborne transmission of infectious agents from experimental and field studies and discusses how airborne pathogens can contaminate other parts of the environment to give rise to secondary vehicles leading air-surface-air nexus with possible transmission to susceptible hosts. The following groups of human pathogens are covered because of their known or potential airborne spread: vegetative bacteria (staphylococci and legionellae), fungi (Aspergillus, Penicillium, and Cladosporium spp and Stachybotrys chartarum), enteric viruses (noro- and rotaviruses), respiratory viruses (influenza and coronaviruses), mycobacteria (tuberculous and nontuberculous), and bacterial spore formers (Clostridium difficile and Bacillus anthracis). An overview of methods for experimentally generating and recovering airborne human pathogens is included, along with a discussion of factors that influence microbial survival in indoor air. Available guidelines from the U.S. Environmental Protection Agency and other global regulatory bodies for the study of airborne pathogens are critically reviewed with particular reference to microbial surrogates that are recommended. Recent developments in experimental facilities to contaminate indoor air with microbial aerosols are presented, along with emerging technologies to decontaminate indoor air under field-relevant conditions. Furthermore, the role that air decontamination may play in reducing the contamination of environmental surfaces and its combined impact on interrupting the risk of pathogen spread in both domestic and institutional settings is discussed. Copyright © 2016. Published by Elsevier Inc.

  5. Optimisation of surfactant decontamination and pre-treatment of waste chicken feathers by using response surface methodology.

    PubMed

    Tesfaye, Tamrat; Sithole, Bruce; Ramjugernath, Deresh; Ndlela, Luyanda

    2018-02-01

    Commercially processed, untreated chicken feathers are biologically hazardous due to the presence of blood-borne pathogens. Prior to valorisation, it is crucial that they are decontaminated to remove the microbial contamination. The present study focuses on evaluating the best technologies to decontaminate and pre-treat chicken feathers in order to make them suitable for valorisation. Waste chicken feathers were washed with three surfactants (sodium dodecyl sulphate) dimethyl dioctadecyl ammonium chloride, and polyoxyethylene (40) stearate) using statistically designed experiments. Process conditions were optimised using response surface methodology with a Box-Behnken experimental design. The data were compared with decontamination using an autoclave. Under optimised conditions, the microbial counts of the decontaminated and pre-treated chicken feathers were significantly reduced making them safe for handling and use for valorisation applications. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Pathogen Decontamination of Food Crop Soil: A Review.

    PubMed

    Gurtler, Joshua B

    2017-09-01

    The purpose of this review is to delineate means of decontaminating soil. This information might be used to mitigate soil-associated risks of foodborne pathogens. The majority of the research in the published literature involves inactivation of plant pathogens in soil, i.e., those pathogens harmful to fruit and vegetable production and ornamental plants. Very little has been published regarding the inactivation of foodborne human pathogens in crop soil. Nevertheless, because decontamination techniques for plant pathogens might also be useful methods for eliminating foodborne pathogens, this review also includes inactivation of plant pathogens, with appropriate discussion and comparisons, in the hopes that these methods may one day be validated against foodborne pathogens. Some of the major soil decontamination methods that have been investigated and are covered include chemical decontamination (chemigation), solarization, steaming, biofumigation, bacterial competitive exclusion, torch flaming, microwave treatment, and amendment with biochar. Other innovative means of inactivating foodborne pathogens in soils may be discovered and explored in the future, provided that these techniques are economically feasible in terms of chemicals, equipment, and labor. Food microbiology and food safety researchers should reach out to soil scientists and plant pathologists to create links where they do not currently exist and strengthen relationships where they do exist to take advantage of multidisciplinary skills. In time, agricultural output and the demand for fresh produce will increase. With advances in the sensitivity of pathogen testing and epidemiological tracebacks, the need to mitigate preharvest bacterial contamination of fresh produce will become paramount. Hence, soil decontamination technologies may become more economically feasible and practical in light of increasing the microbial safety of fresh produce.

  7. 'No touch' technologies for environmental decontamination: focus on ultraviolet devices and hydrogen peroxide systems.

    PubMed

    Weber, David J; Kanamori, Hajime; Rutala, William A

    2016-08-01

    This article reviews 'no touch' methods for disinfection of the contaminated surface environment of hospitalized patients' rooms. The focus is on studies that assessed the effectiveness of ultraviolet (UV) light devices, hydrogen peroxide systems, and self-disinfecting surfaces to reduce healthcare-associated infections (HAIs). The contaminated surface environment in hospitals plays an important role in the transmission of several key nosocomial pathogens including methicillin-resistant Staphylococcus aureus, vancomycin-resistant Enterococcus spp., Clostridium difficile, Acinetobacter spp., and norovirus. Multiple clinical trials have now demonstrated the effectiveness of UV light devices and hydrogen peroxide systems to reduce HAIs. A limited number of studies have suggested that 'self-disinfecting' surfaces may also decrease HAIs. Many studies have demonstrated that terminal cleaning and disinfection with germicides is often inadequate and leaves environmental surfaces contaminated with important nosocomial pathogens. 'No touch' methods of room decontamination (i.e., UV devices and hydrogen peroxide systems) have been demonstrated to reduce key nosocomial pathogens on inoculated test surfaces and on environmental surfaces in actual patient rooms. Further UV devices and hydrogen peroxide systems have been demonstrated to reduce HAI. A validated 'no touch' device or system should be used for terminal room disinfection following discharge of patients on contact precautions. The use of a 'self-disinfecting' surface to reduce HAI has not been convincingly demonstrated.

  8. Minimal impact, waterless decontamination technologies for improving food safety

    USDA-ARS?s Scientific Manuscript database

    Pathogen contamination of produce, meats, poultry, shellfish, and other foods remains an ongoing concern. Chemical sanitizers are widely employed for foods and food contact surfaces. However, there is growing interest in the development of minimal impact, waterless decontamination processes that wil...

  9. Selective decontamination of the digestive tract.

    PubMed

    Krueger, Wolfgang A; Unertl, Klaus E

    2002-04-01

    Ventilator-associated pneumonia usually originates from the patient's oropharyngeal microflora. In selective digestive decontamination, topical antibiotics are applied to the oropharynx and stomach for prevention of pneumonia and other infections, possibly reducing infection-related mortality. Selective digestive decontamination is also used for the prevention of gut-derived infections in acute necrotizing pancreatitis and liver transplantation. Despite numerous clinical trials, selective digestive decontamination remains controversial. Reduction of the incidence of pneumonia is accepted, but the extent of reduction is debated. Mortality was not reduced in most individual trials, but this finding was calculated in meta-analyses, especially for combined use of topical and systemic antibiotics in surgical ICU patients. Some investigators reported increased resistance and a shift to Gram-positive pathogens. Today, it appears that selective means not only selective suppression of pathogenic bacteria but also selection of appropriate groups of patients for underlying diseases and severity of illness, and selection of ICUs, where the endemic resistance patterns might allow the use of selective digestive decontamination at a relatively low risk for increased selection pressure.

  10. Chemical and Biological Substances Decontamination Study for Mars Missions and Terrestrial Applications

    NASA Astrophysics Data System (ADS)

    Pottage, Thomas; Walker, James; Bennett, Allan; Vrublevskis, John; Hovland, Scott

    This study, funded by the European Space Agency (ESA) and undertaken by the Health Protec-tion Agency, UK supported by Systems Engineering and Assessment Ltd., was devised to select suitable current decontamination technologies for development for future manned missions to the Moon and Mars. There is a requirement to decontaminate the habitat module due to the concerns about astronaut ill health, microbial deterioration of materials and potential forward contamination in the case of Mars. In the case of the MIR space station, biodeterioration of components and materials occurred, and dangerous levels of airborne microorganisms were detected during air sampling procedures which lead to the introduction of microbial exposure limits (as MORD SSP 50260) to ensure the health of the crew. COSPAR planetary protection guidelines highlight the need to reduce any potential forward or backwards contamination issues that may occur through the use of Extra Vehicular Activity (EVA) suits whilst on Mars. Decontamination of the suit exterior must be completed before any EVA activity on Mars, whilst a further decontamination cycle must be completed after entry to the airlock following EVA. Technologies and techniques have also been investigated for the microbial reduction of the interior surfaces of the EVA suit to stop biodeterioration of the materials and protect the user from pathogenic microbe accumulation. The first work package reviewed the systems description and requirements as detailed in the statement of work. The requirements were broken down into 12 further requirement sections, where they were updated and expanded, resulted in Technical Note (TN) 1 which was then used as the base document for WP2 and WP3. WP2 investigated the current technologies available for the decontamination of the habitat module interior on missions of up to 6 months and missions that have durations of greater than 6 months. A comprehensive review was carried out for the different methods that could be employed singularly and in combination to decontaminate the habitat. From this review a trade off matrix was compiled scoring each technology on a determined set of parameters. The highest score indicated the most suitable technology. For missions up to 6 months surface cleaning using disinfectant wipes were recommended in combination with an air disinfection/filtration system. For missions greater than 6 months these techniques would be complemented by the addition of a gaseous decontamination system, which could be periodically used to reduce microbial load from inaccessible surfaces. WP3 reviewed the current technologies that could be used for the decontamination of the EVA suit, both external surfaces (after use on the Lunar and Martian surfaces) and internal surfaces. Trade off matrices were constructed to reflect the new parameters for these uses. Only physical decontamination of the exterior surface of the EVA suit is needed for Lunar mission, but for Martian missions this must be enhanced with a gaseous disinfection technology. The interior of the suit can be decontaminated using passive antimicrobial fabrics and active cleaning using disinfectant wipes. WP4 summarised the previous TNs, and included estimates of costs and timelines for the development, based on technology readiness levels, of technologies that need to be flight proven before use on a mission.

  11. Decontamination of indoor air to reduce the risk of airborne infections: Studies on survival and inactivation of airborne pathogens using an aerobiology chamber.

    PubMed

    Sattar, Syed A; Kibbee, Richard J; Zargar, Bahram; Wright, Kathryn E; Rubino, Joseph R; Ijaz, M Khalid

    2016-10-01

    Although indoor air can spread many pathogens, information on the airborne survival and inactivation of such pathogens remains sparse. Staphylococcus aureus and Klebsiella pneumoniae were nebulized separately into an aerobiology chamber (24.0 m 3 ). The chamber's relative humidity and air temperature were at 50% ± 5% and 20°C ± 2°C, respectively. The air was sampled with a slit-to-agar sampler. Between tests, filtered air purged the chamber of any residual airborne microbes. The challenge in the air varied between 4.2 log 10 colony forming units (CFU)/m 3 and 5.0 log 10 CFU/m 3 , sufficient to show a ≥3 log 10 (≥99.9%) reduction in microbial viability in air over a given contact time by the technologies tested. The rates of biologic decay of S aureus and K pneumoniae were 0.0064 ± 0.00015 and 0.0244 ± 0.009 log 10 CFU/m 3 /min, respectively. Three commercial devices, with ultraviolet light and HEPA (high-efficiency particulate air) filtration, met the product efficacy criterion in 45-210 minutes; these rates were statistically significant compared with the corresponding rates of biologic decay of the bacteria. One device was also tested with repeated challenges with aerosolized S aureus to simulate ongoing fluctuations in indoor air quality; it could reduce each such recontamination to an undetectable level in approximately 40 minutes. The setup described is suitable for work with all major classes of pathogens and also complies with the U.S. Environmental Protection Agency's guidelines (2012) for testing air decontamination technologies. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  12. Evaluation of an automated ultraviolet radiation device for decontamination of Clostridium difficile and other healthcare-associated pathogens in hospital rooms.

    PubMed

    Nerandzic, Michelle M; Cadnum, Jennifer L; Pultz, Michael J; Donskey, Curtis J

    2010-07-08

    Environmental surfaces play an important role in transmission of healthcare-associated pathogens. There is a need for new disinfection methods that are effective against Clostridium difficile spores, but also safe, rapid, and automated. The Tru-D Rapid Room Disinfection device is a mobile, fully-automated room decontamination technology that utilizes ultraviolet-C irradiation to kill pathogens. We examined the efficacy of environmental disinfection using the Tru-D device in the laboratory and in rooms of hospitalized patients. Cultures for C. difficile, methicillin-resistant Staphylococcus aureus (MRSA), and vancomycin-resistant Enterococcus (VRE) were collected from commonly touched surfaces before and after use of Tru-D. On inoculated surfaces, application of Tru-D at a reflected dose of 22,000 microWs/cm(2) for approximately 45 minutes consistently reduced recovery of C. difficile spores and MRSA by >2-3 log10 colony forming units (CFU)/cm2 and of VRE by >3-4 log10 CFU/cm(2). Similar killing of MRSA and VRE was achieved in approximately 20 minutes at a reflected dose of 12,000 microWs/cm(2), but killing of C. difficile spores was reduced. Disinfection of hospital rooms with Tru-D reduced the frequency of positive MRSA and VRE cultures by 93% and of C. difficile cultures by 80%. After routine hospital cleaning of the rooms of MRSA carriers, 18% of sites under the edges of bedside tables (i.e., a frequently touched site not easily amenable to manual application of disinfectant) were contaminated with MRSA, versus 0% after Tru-D (P < 0.001). The system required <5 minutes to set up and did not require continuous monitoring. The Tru-D Rapid Room Disinfection device is a novel, automated, and efficient environmental disinfection technology that significantly reduces C. difficile, VRE and MRSA contamination on commonly touched hospital surfaces.

  13. Evaluation of Microwave Steam Bags for the Decontamination of Filtering Facepiece Respirators

    PubMed Central

    Fisher, Edward M.; Williams, Jessica L.; Shaffer, Ronald E.

    2011-01-01

    Reusing filtering facepiece respirators (FFRs) has been suggested as a strategy to conserve available supplies for home and healthcare environments during an influenza pandemic. For reuse to be possible, used FFRs must be decontaminated before redonning to reduce the risk of virus transmission; however, there are no approved methods for FFR decontamination. An effective method must reduce the microbial threat, maintain the function of the FFR, and present no residual chemical hazard. The method should be readily available, inexpensive and easily implemented by healthcare workers and the general public. Many of the general decontamination protocols used in healthcare and home settings are unable to address all of the desired qualities of an efficient FFR decontamination protocol. The goal of this study is to evaluate the use of two commercially available steam bags, marketed to the public for disinfecting infant feeding equipment, for FFR decontamination. The FFRs were decontaminated with microwave generated steam following the manufacturers' instructions then evaluated for water absorption and filtration efficiency for up to three steam exposures. Water absorption of the FFR was found to be model specific as FFRs constructed with hydrophilic materials absorbed more water. The steam had little effect on FFR performance as filtration efficiency of the treated FFRs remained above 95%. The decontamination efficacy of the steam bag was assessed using bacteriophage MS2 as a surrogate for a pathogenic virus. The tested steam bags were found to be 99.9% effective for inactivating MS2 on FFRs; however, more research is required to determine the effectiveness against respiratory pathogens. PMID:21525995

  14. Research Update - Intervention Technologies for Enhancing the Safety and Security of Fresh and Minimally Processed Produce and Solid Plant-Derived Foods

    USDA-ARS?s Scientific Manuscript database

    The produce safety research objectives of Research Project 1935-41420-011 are to 1) understand pathogen microbial ecology and its effects on decontamination efficacy; 2) develop biological-based intervention strategies for pathogen reduction; and 3) develop new effective chemical and physical decont...

  15. Inactivation of foodborne pathogens in chicken purge or skin using a 405-nm LED array

    USDA-ARS?s Scientific Manuscript database

    Raw meat poultry are sometimes contaminated with foodborne pathogens, which can lead to illness in humans. In recent years research has focused on a variety of light technologies to decontaminate food and food contact surfaces during meat and poultry processing. In this study we evaluated the abilit...

  16. Review of mobile communication devices as potential reservoirs of nosocomial pathogens.

    PubMed

    Brady, R R W; Verran, J; Damani, N N; Gibb, A P

    2009-04-01

    Innovation in mobile communication technology has provided novel approaches to the delivery of healthcare and improvements in the speed and quality of routine medical communication. Bacterial contamination of mobile communication devices (MCDs) could be an important issue affecting the implementation of effective infection control measures and might have an impact on efforts to reduce cross-contamination. This review examines recent studies reporting bacterial contamination of MCDs, most demonstrating that 9-25% of MCDs are contaminated with pathogenic bacteria. We examine previously investigated risk factors for MCD contamination in addition to work on surface decontamination of the device. Recommendations to reduce contamination risks include staff education, strict hand hygiene measures, guidelines on device cleaning and consideration of the restrictions regarding use of mobile phone technology in certain high risk areas, for example, operating theatres, intensive care units and burns units. Further work is required to evaluate the benefit of such interventions on MCD contamination and to determine whether a link exists between contamination and subsequent patient infection.

  17. Evaluation of a Biological Pathogen Decontamination Protocol for Animal Feed Mills.

    PubMed

    Huss, Anne R; Cochrane, Roger A; Deliephan, Aiswariya; Stark, Charles R; Jones, Cassandra K

    2015-09-01

    Animal feed and ingredients are potential vectors of pathogenic bacteria. Contaminated ingredients can contaminate facility equipment, leading to cross-contamination of other products. This experiment was conducted to evaluate a standardized protocol for decontamination of an animal feed manufacturing facility using Enterococcus faecium (ATCC 31282) as an indicator. A pelleted swine diet inoculated with E. faecium was manufactured, and environmental samples (swabs, replicate organism detection and counting plates, and air samples) were collected (i) before inoculation (baseline data), (ii) after production of inoculated feed, (iii) after physical removal of organic material using pressurized air, (iv) after application of a chemical sanitizer containing a quaternary ammonium-glutaraldehyde blend, (v) after application of a chemical sanitizer containing sodium hypochlorite, (vi) after facility heat-up to 60 8 C for 24 h, (vii) for 48 h, and (viii) for 72 h. Air samples collected outside the facility confirmed pathogen containment; E. faecium levels were equal to or lower than baseline levels at each sample location. The decontamination step and its associated interactions were the only variables that affected E. faecium incidence (P < 0.0001 versus P > 0.22). After production of the inoculated diet, 85.7% of environmental samples were positive for E. faecium. Physical cleaning of equipment had no effect on contamination (P = 0.32). Chemical cleaning with a quaternary ammonium-glutaraldehyde blend and sodium hypochlorite each significantly reduced E. faecium contamination (P < 0.0001) to 28.6 and 2.4% of tested surfaces, respectively. All samples were negative for E. faecium after 48 h of heating. Both wet chemical cleaning and facility heating but not physical cleaning resulted in substantial E. faecium decontamination. These results confirmed both successful containment and decontamination of biological pathogens in the tested pilot-scale feed mill.

  18. Gaseous and air decontamination technologies for Clostridium difficile in the healthcare environment.

    PubMed

    Davies, A; Pottage, T; Bennett, A; Walker, J

    2011-03-01

    The recent data for hospital-acquired infections suggest that infection rates for meticillin-resistant Staphylococcus aureus (MRSA) and Clostridium difficile are beginning to decrease. However, while there is still pressure to maintain this trend, the resistance of C. difficile spores to standard detergents continues to present a problem for many UK hospitals trying to prevent its spread or control outbreaks. Alternative disinfection technologies such as gaseous decontamination are currently being marketed to the healthcare sector as an alternative/supplement to manual disinfection, and have been shown to be effective in reducing environmental contamination. When used correctly, they offer a complementary technology to manual cleaning that increases the probability of an effective reduction in viability and provides a comparatively uniform distribution of disinfectant. Three gaseous decontamination technologies are examined for their suitability in reducing environmental contamination with C. difficile: gaseous hydrogen peroxide, chlorine dioxide and ozone. Air decontamination and UV-based technologies are also briefly described. We conclude that while there is a role to play for these new technologies in the decontamination of ward surfaces contaminated with C. difficile, the requirement for both a preclean before use and the limited 'in vivo' evidence means that extensive field trials are necessary to determine their cost-effectiveness in a healthcare setting. Copyright © 2010 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.

  19. Novel Laser Ablation Technology for Surface Decontamination

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cheng, Chung H.

    2004-06-01

    Laser ablation for surface cleaning has been pursued for the removal of paint on airplanes. It has also been pursued for the cleaning of semiconductor surfaces. However, all these approaches have been pursued by laser ablation in air. For highly contaminated surface, laser ablation in air can easily cause secondary contamination. Thus it is not suitable to apply to achieve surface decontamination for DOE facilities since many of these facilities have radioactive contaminants on the surface. Any secondary contamination will be a grave concern. The objective of this project is to develop a novel technology for laser ablation in liquidmore » for surface decontamination. It aims to achieve more efficient surface decontamination without secondary contamination and to evaluate the economic feasibility for large scale surface decontamination with laser ablation in liquid. When laser ablation is pursued in the solution, all the desorbed contaminants will be confined in liquid. The contaminants can be precipitated and subsequently contained in a small volume for disposal. It can reduce the risk of the decontamination workers. It can also reduce the volume of contaminants dramatically.« less

  20. A novel water-assisted pulsed light processing for decontamination of blueberries.

    PubMed

    Huang, Yaoxin; Chen, Haiqiang

    2014-06-01

    Sample heating and shadowing effect have limited the application of pulsed light (PL) technology for decontamination of fresh produce. In this study, a novel setup using water-assisted PL processing was developed to overcome these limitations. Blueberries inoculated with Escherichia coli O157:H7 or Salmonella were either treated with PL directly (dry PL treatment) or immersed in agitated water during the PL treatment (wet PL treatment) for 5-60 s. Although both pathogens were effectively inactivated by the dry PL treatments, the appearance of the blueberries was adversely affected and a maximum temperature of 64.8 °C on the blueberry surface was recorded. On the other hand, the visual appearance of blueberries remained unchanged after wet PL treatments and sample heating was significantly reduced. The wet PL treatments were more effective than chlorine washing on inactivating both pathogens. After a 60-s wet PL treatment, the populations of E. coli O157:H7 inoculated on calyx and skin of blueberries were reduced by 3.0 and >5.8 log CFU/g, respectively. Salmonella on blueberry calyx and skin was reduced by 3.6 and >5.9 log CFU/g, respectively. No viable bacterial cells were recovered from the water used in the wet PL treatments, demonstrating that this setup could prevent the risk of cross-contamination during fresh produce washing. Our results suggest that this new water-assisted PL treatment could be a potential non-chemical alternative (residue free) to chlorine washing since it is both more effective and environmentally friendly than chlorine washing. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Investigation of critical inter-related factors affecting the efficacy of pulsed light for inactivating clinically relevant bacterial pathogens.

    PubMed

    Farrell, H P; Garvey, M; Cormican, M; Laffey, J G; Rowan, N J

    2010-05-01

    To investigate critical electrical and biological factors governing the efficacy of pulsed light (PL) for the in vitro inactivation of bacteria isolated from the clinical environment. Development of this alternative PL decontamination approach is timely, as the incidence of health care-related infections remains unacceptably high. Predetermined cell numbers of clinically relevant Gram-positive and Gram-negative bacteria were inoculated separately on agar plates and were flashed with

  2. Variable high pressure processing sensitivities for GII human noroviruses

    USDA-ARS?s Scientific Manuscript database

    Human norovirus (HuNoV) is the leading cause of foodborne diseases worldwide. High pressure processing (HPP) is one of the most promising non-thermal technologies for decontamination of viral pathogens in foods. However, the survival of HuNoVs by HPP is poorly understood because these viruses cann...

  3. Nonacid meat decontamination technologies: model studies and commercial applications.

    PubMed

    Sofos, J N; Smith, G C

    1998-11-10

    Increased consumer awareness and concern about microbial foodborne diseases has resulted in intensified efforts to reduce contamination of raw meat, as evidenced by new meat and poultry inspection regulations being implemented in the United States. In addition to requiring operation of meat and poultry slaughtering and processing plants under the principles of the hazard analysis critical control point (HACCP) system, the new regulations have established microbiological testing criteria for Escherichia coli and Salmonella, as a means of evaluating plant performance. These developments have renewed and intensified interest in the development and commercial application of meat and poultry decontamination procedures. Technologies developed and evaluated for decontamination include live animal cleaning/washing, chemical dehairing, carcass knife-trimming to remove physical contaminants, steam/hot water-vacuuming for spot-cleaning/decontamination of carcasses, spray washing/rinsing of carcasses with water of low or high pressures and temperatures or chemical solutions, and exposure of carcass sides to pressurized steam. Under appropriate conditions, the technologies applied to carcasses may reduce mean microbiological counts by approximately one-three log colony forming units (cfu)/cm2, and some of them have been approved and are employed in commercial applications (i.e., steam-vacuuming; carcass spray-washing with water, chlorine, organic acid or trisodium phosphate solutions; hot water deluging/spraying/rinsing, and pressurized steam). The contribution of these decontamination technologies to the enhancement of food safety will be determined over the long term, as surveillance data on microbial foodborne illness are collected. This review examines carcass decontamination technologies, other than organic acids, with emphasis placed on recent advances and commercial applications.

  4. Food decontamination using nanomaterials

    USDA-ARS?s Scientific Manuscript database

    The research indicates that nanomaterials including nanoemulsions are promising decontamination media for the reduction of food contaminating pathogens. The inhibitory effect of nanoparticles for pathogens could be due to deactivate cellular enzymes and DNA; disrupting of membrane permeability; and/...

  5. Bacterial decontamination using ambient pressure nonthermal discharges

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Birmingham, J.G.; Hammerstrom, D.J.

    2000-02-01

    Atmospheric pressure nonthermal plasmas can efficiently deactivate bacteria in gases, liquids, and on surfaces, as well as can decompose hazardous chemicals. This paper focuses on the changes to bacterial spores and toxic biochemical compounds, such as mycotoxins, after their treatment in ambient pressure discharges. The ability of nonthermal plasmas to decompose toxic chemicals and deactivate hazardous biological materials has been applied to sterilizing medical instruments, ozonating water, and purifying air. In addition, the fast lysis of bacterial spores and other cells has led us to include plasma devices within pathogen detection instruments, where nucleic acids must be accessed. Decontaminating chemicalmore » and biological warfare materials from large, high value targets such as building surfaces, after a terrorist attack, are especially challenging. A large area plasma decontamination technology is described.« less

  6. Prevention of Infection Due to Clostridium difficile.

    PubMed

    Cooper, Christopher C; Jump, Robin L P; Chopra, Teena

    2016-12-01

    Clostridium difficile is one of the foremost nosocomial pathogens. Preventing infection is particularly challenging. Effective prevention efforts typically require a multifaceted bundled approach. A variety of infection control procedures may be advantageous, including strict hand decontamination with soap and water, contact precautions, and using chlorine-containing decontamination agents. Additionally, risk factor reduction can help reduce the burden of disease. The risk factor modification is principally accomplished though antibiotic stewardship programs. Unfortunately, most of the current evidence for prevention is in acute care settings. This review focuses on preventative approaches to reduce the incidence of Clostridium difficile infection in healthcare settings. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Egg Safety in the Realm of Preharvest Food Safety.

    PubMed

    Singh, Manpreet; Brar, Jagpinder

    2016-08-01

    Eggs are nutritious, yet they are a highly perishable commodity like other protein sources such as meat. Even though steps are taken all along the production process of shell eggs, from farm to table, the potential for contamination of the shells and egg contents poses a high risk to consumers. The main sources of contamination can be categorized as vertical transmission, in which the layers can be carriers of pathogens and can pass them on during egg formation, and horizontal transmission, in which environmental factors such as water, feed, layer houses, and personnel are the main source of contamination. Ongoing preharvest practices might not be enough to completely eliminate pathogens from shell eggs; however, consistently following good practices along with proper handling during transportation and retail sale and by consumers can be significant in reducing the risk. This article discusses the various aspects of production practices, their potential for cross-contamination, and decontamination technologies for shell eggs.

  8. Cold Atmospheric Plasma Technology for Decontamination of Space Equipment

    NASA Astrophysics Data System (ADS)

    Thomas, Hubertus; Rettberg, Petra; Shimizu, Tetsuji; Thoma, Markus; Morfill, Gregor; Zimmermann, Julia; Müller, Meike; Semenov, Igor

    2016-07-01

    Cold atmospheric plasma (CAP) technology is very fast and effective in inactivation of all kinds of pathogens. It is used in hygiene and especially in medicine, since the plasma treatment can be applied to sensitive surfaces, like skin, too. In a first study to use CAP for the decontamination of space equipment we could show its potential as a quite promising alternative to the standard "dry heat" and H2O2 methods [Shimizu et al. Planetary and Space Science, 90, 60-71. (2014)]. In a follow-on study we continue the investigations to reach high application level of the technology. First, we redesign the actual setup to a plasma-gas circulation system, increasing the effectivity of inactivation and the sustainability. Additionally, we want to learn more about the plasma chemistry processes involved in the inactivation. Therefore, we perform detailed plasma and gas measurements and compare them to numerical simulations. The latter will finally be used to scale the decontamination system to sizes useful also for larger space equipment. Typical materials relevant for space equipment will be tested and investigated on surface material changes due to the plasma treatment. Additionally, it is planned to use electronic boards and compare their functionality before and after the CAP expose. We will give an overview on the status of the plasma decontamination project funded by the Bavarian Ministry of Economics.

  9. Controlling Hospital-Acquired Infection: Focus on the Role of the Environment and New Technologies for Decontamination

    PubMed Central

    2014-01-01

    SUMMARY There is increasing interest in the role of cleaning for managing hospital-acquired infections (HAI). Pathogens such as vancomycin-resistant enterococci (VRE), methicillin-resistant Staphylococcus aureus (MRSA), multiresistant Gram-negative bacilli, norovirus, and Clostridium difficile persist in the health care environment for days. Both detergent- and disinfectant-based cleaning can help control these pathogens, although difficulties with measuring cleanliness have compromised the quality of published evidence. Traditional cleaning methods are notoriously inefficient for decontamination, and new approaches have been proposed, including disinfectants, steam, automated dispersal systems, and antimicrobial surfaces. These methods are difficult to evaluate for cost-effectiveness because environmental data are not usually modeled against patient outcome. Recent studies have reported the value of physically removing soil using detergent, compared with more expensive (and toxic) disinfectants. Simple cleaning methods should be evaluated against nonmanual disinfection using standardized sampling and surveillance. Given worldwide concern over escalating antimicrobial resistance, it is clear that more studies on health care decontamination are required. Cleaning schedules should be adapted to reflect clinical risk, location, type of site, and hand touch frequency and should be evaluated for cost versus benefit for both routine and outbreak situations. Forthcoming evidence on the role of antimicrobial surfaces could supplement infection prevention strategies for health care environments, including those targeting multidrug-resistant pathogens. PMID:25278571

  10. Controlling hospital-acquired infection: focus on the role of the environment and new technologies for decontamination.

    PubMed

    Dancer, Stephanie J

    2014-10-01

    There is increasing interest in the role of cleaning for managing hospital-acquired infections (HAI). Pathogens such as vancomycin-resistant enterococci (VRE), methicillin-resistant Staphylococcus aureus (MRSA), multiresistant Gram-negative bacilli, norovirus, and Clostridium difficile persist in the health care environment for days. Both detergent- and disinfectant-based cleaning can help control these pathogens, although difficulties with measuring cleanliness have compromised the quality of published evidence. Traditional cleaning methods are notoriously inefficient for decontamination, and new approaches have been proposed, including disinfectants, steam, automated dispersal systems, and antimicrobial surfaces. These methods are difficult to evaluate for cost-effectiveness because environmental data are not usually modeled against patient outcome. Recent studies have reported the value of physically removing soil using detergent, compared with more expensive (and toxic) disinfectants. Simple cleaning methods should be evaluated against nonmanual disinfection using standardized sampling and surveillance. Given worldwide concern over escalating antimicrobial resistance, it is clear that more studies on health care decontamination are required. Cleaning schedules should be adapted to reflect clinical risk, location, type of site, and hand touch frequency and should be evaluated for cost versus benefit for both routine and outbreak situations. Forthcoming evidence on the role of antimicrobial surfaces could supplement infection prevention strategies for health care environments, including those targeting multidrug-resistant pathogens. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  11. System decontamination as a tool to control radiation fields

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Riess, R.; Bertholdt, H.O.

    1995-03-01

    Since chemical decontamination of the Reactor Coolant Systems (RCS) and subsystems has the highest potential to reduce radiation fields in a short term this technology has gained an increasing importance. The available decontamination process at Siemens, i.e., the CORD processes, will be described. It is characterized by using permanganic acid for preoxidation and diluted organic acid for the decontamination step. It is a regenerative process resulting in very low waste volumes. This technology has been used frequently in Europe and Japan in both RCS and subsystems. An overview will be given i.e. on the 1993 applications. This overview will includemore » plant, scope, date of performance, system volume specal features of the process removed activities, decon factor time, waste volumes, and personnel dose during decontamination. This overview will be followed by an outlook on future developments in this area.« less

  12. In vitro human skin permeation and decontamination of 2-chloroethyl ethyl sulfide (CEES) using Dermal Decontamination Gel (DDGel) and Reactive Skin Decontamination Lotion (RSDL).

    PubMed

    Cao, Yachao; Hui, Xiaoying; Zhu, Hanjiang; Elmahdy, Akram; Maibach, Howard

    2018-07-01

    This study compared the efficiency for in vitro human skin decontamination using DDGel and RSDL. Experiments were performed using in vitro human skin models, in which skin was mounted onto Flow-Through diffusion cells. The mass of 14 -C CEES removed from skin surface after decontamination was quantitated by measuring radioactivity with a liquid scintillation spectrometer. Both decontaminants removed more than 82% of CEES from skin. DDGel skin decontamination significantly reduced toxicant amount when compared to RSDL. Mean CEES remaining in stratum corneum (SC), viable epidermis, dermis, and systemic absorption of DDGel and RSDL were, 0.12 and 0.55% (P < 0.01), 0.31 and 0.95% (p < 0.01), 1.08 and 2.92% (p < 0.05), 3.13 and 6.34% (p < 0.05), respectively. DDGel showed higher decontamination efficiency (twice decontamination efficacy factor, DEF) than RSDL and efficiently removed chemicals from the skin surface, importantly back-extracted from the SC, and significantly reduced both chemical penetration into skin and systemic absorption. Thus, DDGel can offer a potential as a next generation skin decontamination platform technology for military and civilian applications. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. [Advances in peroxide-based decontaminating technologies].

    PubMed

    Xi, Hai-ling; Zhao, San-ping; Zhou, Wen

    2013-05-01

    With the boosting demand for eco-friendly decontaminants, great achievements in peroxide-based decontaminating technologies have been made in recent years. These technologies have been applied in countering chemical/biological terrorist attacks, dealing with chemical/biological disasters and destructing environmental pollutants. Recent research advances in alpha-nucleophilic/oxidative reaction mechanisms of peroxide-based decontamination against chemical warfare agents were reviewed, and some classical peroxide-based decontaminants such as aqueous decontaminating solution, decontaminating foam, decontaminating emulsions, decontaminating gels, decontaminating vapors, and some newly developed decontaminating media (e.g., peroxide-based self-decontaminating materials and heterogeneous nano-catalytic decontamination systems) were introduced. However, currently available peroxide-based decontaminants still have some deficiencies. For example, their decontamination efficiencies are not as high as those of chlorine-containing decontaminants, and some peroxide-based decontaminants show relatively poor effect against certain agents. More study on the mechanisms of peroxide-based decontaminants and the interfacial interactions in heterogeneous decontamination media is suggested. New catalysts, multifunctional surfactants, self-decontaminating materials and corrosion preventing technologies should be developed before peroxide-based decontaminants really become true "green" decontaminants.

  14. National demonstration of full reactor coolant system (RCS) chemical decontamination at Indian Point 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Trovato, S.A.; Parry, J.O.

    1995-03-01

    Key to the safe and efficient operation of the nation`s civilian nuclear power plants is the performance of maintenance activities within regulations and guidelines for personnel radiation exposure. However, maintenance activities, often performed in areas of relatively high radiation fields, will increase as the nation`s plant age. With the Nuclear Regulatory Commission (NRC) lowering the allowable radiation exposure to plant workers in 1994 and considering further reductions and regulations in the future, it is imperative that new techniques be developed and applied to reduce personnel exposure. Full primary system chemical decontamination technology offers the potential to be single most effectivemore » method of maintaining workers exposure {open_quotes}as low as reasonably achievable{close_quotes} (ALARA) while greatly reducing plant operation and maintenance (O&M) costs. A three-phase program underway since 1987, has as its goal to demonstrate that full RCS decontamination is a visible technology to reduce general plant radiation levels without threatening the long term reliability and operability of a plant. This paper discusses research leading to and plans for a National Demonstration of Full RCS Chemical Decontamination at Indian Point 2 nuclear generating station in 1995.« less

  15. Decontamination Technologies, Task 3, Urban Remediation and Response Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heiser,J.; Sullivan, T.

    In the aftermath of a Radiological Dispersal Device (RDD, also known as a dirty bomb) it will be necessary to remediate the site including building exteriors and interiors, equipment, pavement, vehicles, personal items etc. Remediation will remove or reduce radioactive contamination from the area using a combination of removing and disposing of many assets (including possible demolition of buildings), decontaminating and returning to service other assets, and fixing in place or leaving in place contamination that is deemed 'acceptable'. The later will require setting acceptable dose standards, which will require negotiation with all involved parties and a balance of riskmore » and cost to benefit. To accomplish the first two, disposal or decontamination, a combination of technologies will be deployed that can be loosely classified as: Decontamination; Equipment removal and size reduction; and Demolition. This report will deal only with the decontamination technologies that will be used to return assets to service or to reduce waste disposal. It will not discuss demolition, size reduction or removal technologies or equipment (e.g., backhoe mounted rams, rock splitter, paving breakers and chipping hammers, etc.). As defined by the DOE (1994), decontamination is removal of radiological contamination from the surfaces of facilities and equipment. Expertise in this field comes primarily from the operation and decommissioning of DOE and commercial nuclear facilities as well as a small amount of ongoing research and development closely related to RDD decontamination. Information related to decontamination of fields, buildings, and public spaces resulting from the Goiania and Chernobyl incidents were also reviewed and provide some meaningful insight into decontamination at major urban areas. In order to proceed with decontamination, the item being processed needs to have an intrinsic value that exceeds the cost of the cleaning and justifies the exposure of any workers during the decontamination process(es). In the case of an entire building, the value may be obvious; it's costly to replace the structure. For a smaller item such as a vehicle or painting, the cost versus benefit of decontamination needs to be evaluated. This will be determined on a case by case basis and again is beyond the scope of this report, although some thoughts on decontamination of unique, personal and high value items are given. But, this is clearly an area that starting discussions and negotiations early on will greatly benefit both the economics and timeliness of the clean up. In addition, high value assets might benefit from pre-event protection such as protective coatings or HEPA filtered rooms to prevent contaminated outside air from entering the room (e.g., an art museum).« less

  16. Radiation resistances and decontamination of common pathogenic bacteria contaminated in white scar oyster ( Crassostrea belcheri) in Thailand

    NASA Astrophysics Data System (ADS)

    Thupila, Nunticha; Ratana-arporn, Pattama; Wilaipun, Pongtep

    2011-07-01

    In Thailand, white scar oyster ( Crassostrea belcheri) was ranked for premium quality, being most expensive and of high demand. This oyster is often eaten raw, hence it may pose health hazards to consumers when contaminated with food-borne pathogens. As limited alternative methods are available to sterilize the oyster while preserving the raw characteristic, irradiation may be considered as an effective method for decontamination. In this study, the radiation resistance of pathogenic bacteria commonly contaminating the oyster and the optimum irradiation doses for sterilization of the most radiation resistant bacteria were investigated. The radiation decimal reduction doses ( D10) of Salmonella Weltevreden DMST 33380, Vibrio parahaemolyticus ATCC 17802 and Vibrio vulnificus DMST 5852 were determined in broth culture and inoculated oyster homogenate. The D10 values of S. Weltevreden, V. parahaemolyticus and V. vulnificus in broth culture were 0.154, 0.132 and 0.059 kGy, while those of inoculated oyster homogenate were 0.330, 0.159 and 0.140 kGy, respectively. It was found that among the pathogens tested, S. Weltevreden was proved to be the most resistant species. An irradiation dose of 1.5 kGy reduced the counts of 10 5 CFU/g S. Weltevreden inoculated in oyster meat to an undetectable level. The present study indicated that a low-dose irradiation can improve the microbial quality of oyster and further reduce the risks from the food-borne pathogens without adversely affecting the sensory attributes.

  17. Atmospheric cold plasma inactivation of Escherichia coli 0157:H7 and aerobic microorganisms in cold-stored romaine lettuce packaged in a commerical polyethylene terephthalate container

    USDA-ARS?s Scientific Manuscript database

    Leafy greens continue to be a significant vector for foodborne pathogens, including Escherichia coli O157:H7. Dielectric barrier discharge atmospheric cold plasma (ACP) treatment is a promising method for microbial decontamination of produce. An important aspect of this technology is the potential f...

  18. Selective decontamination of the digestive tract in gastrointestinal surgery: useful in infection prevention? A systematic review.

    PubMed

    Abis, Gabor S A; Stockmann, Hein B A C; van Egmond, Marjolein; Bonjer, Hendrik J; Vandenbroucke-Grauls, Christina M J E; Oosterling, Steven J

    2013-12-01

    Gastrointestinal surgery is associated with a high incidence of infectious complications. Selective decontamination of the digestive tract is an antimicrobial prophylaxis regimen that aims to eradicate gastrointestinal carriage of potentially pathogenic microorganisms and represents an adjunct to regular prophylaxis in surgery. Relevant studies were identified using bibliographic searches of MEDLINE, EMBASE, and the Cochrane database (period from 1970 to November 1, 2012). Only studies investigating selective decontamination of the digestive tract in gastrointestinal surgery were included. Two randomized clinical trials and one retrospective case-control trial showed significant benefit in terms of infectious complications and anastomotic leakage in colorectal surgery. Two randomized controlled trials in esophageal surgery and two randomized clinical trials in gastric surgery reported lower levels of infectious complications. Selective decontamination of the digestive tract reduces infections following esophageal, gastric, and colorectal surgeries and also appears to have beneficial effects on anastomotic leakage in colorectal surgery. We believe these results provide the basis for a large multicenter prospective study to investigate the role of selective decontamination of the digestive tract in colorectal surgery.

  19. Evaluation of an enclosed ultraviolet-C radiation device for decontamination of mobile handheld devices.

    PubMed

    Mathew, J Itty; Cadnum, Jennifer L; Sankar, Thriveen; Jencson, Annette L; Kundrapu, Sirisha; Donskey, Curtis J

    2016-06-01

    Mobile handheld devices used in health care settings may become contaminated with health care-associated pathogens. We demonstrated that an enclosed ultraviolet-C radiation device was effective in rapidly reducing methicillin-resistant Staphylococcus aureus, and with longer exposure times, Clostridium difficile spores, on glass slides and reducing contamination on in-use mobile handheld devices. Published by Elsevier Inc.

  20. Radioactive scrap metal decontamination technology assessment report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buckentin, J.M.; Damkroger, B.K.; Schlienger, M.E.

    1996-04-01

    Within the DOE complex there exists a tremendous quantity of radioactive scrap metal. As an example, it is estimated that within the gaseous diffusion plants there exists in excess of 700,000 tons of contaminated stainless steel. At present, valuable material is being disposed of when it could be converted into a high quality product. Liquid metal processing represents a true recycling opportunity for this material. By applying the primary production processes towards the material`s decontamination and re-use, the value of the strategic resource is maintained while drastically reducing the volume of material in need of burial. Potential processes for themore » liquid metal decontamination of radioactively contaminated metal are discussed and contrasted. Opportunities and technology development issues are identified and discussed. The processes compared are: surface decontamination; size reduction, packaging and burial; melting technologies; electric arc melting; plasma arc centrifugal treatment; air induction melting; vacuum induction melting; and vacuum induction melting and electroslag remelting.« less

  1. Modern technologies for improving cleaning and disinfection of environmental surfaces in hospitals.

    PubMed

    Boyce, John M

    2016-01-01

    Experts agree that careful cleaning and disinfection of environmental surfaces are essential elements of effective infection prevention programs. However, traditional manual cleaning and disinfection practices in hospitals are often suboptimal. This is often due in part to a variety of personnel issues that many Environmental Services departments encounter. Failure to follow manufacturer's recommendations for disinfectant use and lack of antimicrobial activity of some disinfectants against healthcare-associated pathogens may also affect the efficacy of disinfection practices. Improved hydrogen peroxide-based liquid surface disinfectants and a combination product containing peracetic acid and hydrogen peroxide are effective alternatives to disinfectants currently in widespread use, and electrolyzed water (hypochlorous acid) and cold atmospheric pressure plasma show potential for use in hospitals. Creating "self-disinfecting" surfaces by coating medical equipment with metals such as copper or silver, or applying liquid compounds that have persistent antimicrobial activity surfaces are additional strategies that require further investigation. Newer "no-touch" (automated) decontamination technologies include aerosol and vaporized hydrogen peroxide, mobile devices that emit continuous ultraviolet (UV-C) light, a pulsed-xenon UV light system, and use of high-intensity narrow-spectrum (405 nm) light. These "no-touch" technologies have been shown to reduce bacterial contamination of surfaces. A micro-condensation hydrogen peroxide system has been associated in multiple studies with reductions in healthcare-associated colonization or infection, while there is more limited evidence of infection reduction by the pulsed-xenon system. A recently completed prospective, randomized controlled trial of continuous UV-C light should help determine the extent to which this technology can reduce healthcare-associated colonization and infections. In conclusion, continued efforts to improve traditional manual disinfection of surfaces are needed. In addition, Environmental Services departments should consider the use of newer disinfectants and no-touch decontamination technologies to improve disinfection of surfaces in healthcare.

  2. For whom should we use selective decontamination of the digestive tract?

    PubMed

    de Smet, Anne Marie G A; Bonten, Marc J M; Kluytmans, Jan A J W

    2012-04-01

    This review discusses the relevant studies on selective decontamination of the digestive tract (SDD) published between 2009 and mid-2011. In a multicenter cluster-randomized cross-over study in the Netherlands, SDD and selective oropharyngeal decontamination (SOD) were associated with higher survival at day 28, with a lower incidence of ICU-acquired bacteremia and with less acquisition of respiratory tract colonization with antibiotic resistant pathogens, compared to standard care. A post-hoc analysis of this study suggests that SDD might be more effective in surgical patients and SOD in nonsurgical patients. In a randomized study perioperative use of SDD in patients undergoing gastrointestinal surgery was associated with lower incidences of anastomotic leakages. A Cochrane meta-analysis, not including any of the before mentioned studies, reported a reduction of respiratory tract infections in studies by using topical antibiotics only and higher survival rates when topical antibiotics were combined with parenteral antibiotics. Recent studies show that in ICUs with low levels of antibiotic resistance, SDD and SOD improved patient outcome and reduced infections and carriage with antibiotic-resistant pathogens. The effect in settings with higher levels of antibiotic resistance remains to be determined as well as the efficacy of SDD and SOD in specific patient groups.

  3. Application of Quercus infectoria extract as a natural antimicrobial agent for chicken egg decontamination.

    PubMed

    Tayel, Ahmed A; El-Sedfy, Mahmoud A; Ibrahim, Ahmed I; Moussa, Shaaban H

    2018-04-21

    Egg contamination with microbial pathogens is an enduring worldwide concern. Natural products are frequently recommended as ideal alternatives to substitute synthetic and chemical antimicrobials. Oak galls (Quercus infectoria) are aberrant growths on oak trees that have many medicinal and pharmaceutical applications. Q. infectoria extract (QIE) antimicrobial action was assessed against many microbial species, and used for eggshell decontamination. QIE antimicrobial activity was evidenced against Staphylococcus aureus, Escherichia coli, Pseudomonas aeruginosa, Salmonella Typhimurium and Candida albicans, using different assay methods. Disinfection of eggshell microbial contamination, by immersion in 1% QIE solution, sharply reduced total colony count, yeasts and molds, Enterobacteriaceae. E. coli and S. aureus were completely inhibited after 60min of immersion in QIE. QIE biochemical analysis revealed elevated contents of phenolic and flavonoid compounds. The captured micrographs of S. aureus cells treated with QIE showed strong alterations in cell morphology; cells were entirely lysed and ruptured after 6h of treatment. QIE can be recommended as an effective and natural disinfectant for decontaminating eggshells from pathogenic microorganisms. Copyright © 2018 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.

  4. Assessing cost and effectiveness of radiation decontamination in Fukushima Prefecture, Japan.

    PubMed

    Yasutaka, Tetsuo; Naito, Wataru

    2016-01-01

    Despite the enormous cost of radiation decontamination in Fukushima Prefecture, it is not clear what levels of reduction in external radiation exposure are possible in the Special Decontamination Area, the Intensive Contamination Survey Areas and the whole of Fukushima. The objective of this study was to evaluate the cost and effectiveness of radiation decontamination in Fukushima Prefecture in its entirety. Using a geographic information system, we calculated the costs of removal, storage containers, transport, and temporary and interim storage facilities as well as the reduction in air dose rate for a cumulative external exposure for 9000 1 km × 1 km mesh units incorporating 51 municipalities. The decontamination cost for the basic scenario, for which forested areas within 20 m of habitation areas were decontaminated, was JPY2.53-5.12 trillion; the resulting reduction in annual external dose was about 2500 person-Sv. The transport, storage, and administrative costs of decontamination waste and removed soil reached JPY1.55-2.12 trillion under this scenario. Although implementing decontamination of all forested areas provides some major reductions in the external radiation dose for the average inhabitant, decontamination costs could potentially exceed JPY16 trillion. These results indicate that technologies for reducing the volume of decontamination waste and removed soil should be considered to reduce storage costs and that further discussions about forest decontamination policies are needed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Functional Metagenomics of Spacecraft Assembly Cleanrooms: Presence of Virulence Factors Associated with Human Pathogens

    PubMed Central

    Bashir, Mina; Ahmed, Mahjabeen; Weinmaier, Thomas; Ciobanu, Doina; Ivanova, Natalia; Pieber, Thomas R.; Vaishampayan, Parag A.

    2016-01-01

    Strict planetary protection practices are implemented during spacecraft assembly to prevent inadvertent transfer of earth microorganisms to other planetary bodies. Therefore, spacecraft are assembled in cleanrooms, which undergo strict cleaning and decontamination procedures to reduce total microbial bioburden. We wanted to evaluate if these practices selectively favor survival and growth of hardy microorganisms, such as pathogens. Three geographically distinct cleanrooms were sampled during the assembly of three NASA spacecraft: The Lockheed Martin Aeronautics' Multiple Testing Facility during DAWN, the Kennedy Space Center's Payload Hazardous Servicing Facility (KSC-PHSF) during Phoenix, and the Jet Propulsion Laboratory's Spacecraft Assembly Facility during Mars Science Laboratory. Sample sets were collected from the KSC-PHSF cleanroom at three time points: before arrival of the Phoenix spacecraft, during the assembly and testing of the Phoenix spacecraft, and after removal of the spacecraft from the KSC-PHSF facility. All samples were subjected to metagenomic shotgun sequencing on an Illumina HiSeq 2500 platform. Strict decontamination procedures had a greater impact on microbial communities than sampling location Samples collected during spacecraft assembly were dominated by Acinetobacter spp. We found pathogens and potential virulence factors, which determine pathogenicity in all the samples tested during this study. Though the relative abundance of pathogens was lowest during the Phoenix assembly, potential virulence factors were higher during assembly compared to before and after assembly, indicating a survival advantage. Decreased phylogenetic and pathogenic diversity indicates that decontamination and preventative measures were effective against the majority of microorganisms and well implemented, however, pathogen abundance still increased over time. Four potential pathogens, Acinetobacter baumannii, Acinetobacter lwoffii, Escherichia coli and Legionella pneumophila, and their corresponding virulence factors were present in all cleanroom samples. This is the first functional metagenomics study describing presence of pathogens and their corresponding virulence factors in cleanroom environments. The results of this study should be considered for microbial monitoring of enclosed environments such as schools, homes, hospitals and more isolated habitation such the International Space Station and future manned missions to Mars. PMID:27667984

  6. Airborne Pathogens inside Automobiles for Domestic Use: Assessing In-Car Air Decontamination Devices Using Staphylococcus aureus as the Challenge Bacterium.

    PubMed

    Sattar, Syed A; Zargar, Bahram; Wright, Kathryn E; Rubino, Joseph R; Ijaz, M Khalid

    2017-05-15

    Family cars represent ∼74% of the yearly global output of motorized vehicles. With a life expectancy of ∼8 decades in many countries, the average person spends >100 min daily inside the confined and often shared space of the car, with exposure to a mix of potentially harmful microbes. Can commercial in-car microbial air decontamination devices mitigate the risk? Three such devices (designated devices 1 to 3) with HEPA filters were tested in the modified passenger cabin (3.25 m 3 ) of a four-door sedan housed within a biosafety level 3 containment facility. Staphylococcus aureus (ATCC 6538) was suspended in a soil load to simulate the presence of body fluids and aerosolized into the car's cabin with a 6-jet Collison nebulizer. A muffin fan (80 mm by 80 mm, with an output of 0.17 m 3 /min) circulated the air inside. Plates (150 mm diameter) of Trypticase soy agar (TSA), placed inside a programmable slit-to-agar sampler, were held at 36 ± 1°C for 18 to 24 h and examined for CFU. The input dose of the test bacterium, its rate of biological decay, and the log 10 reductions by the test devices were analyzed. The arbitrarily set performance criterion was the time in hours a device took for a 3-log 10 reduction in the level of airborne challenge bacterium. On average, the level of S. aureus challenge in the air varied between 4.2 log 10 CFU/m 3 and 5.5 log 10 CFU/m 3 , and its rate of biological decay was -0.0213 ± 0.0021 log 10 CFU/m 3 /min. Devices 1 to 3 took 2.3, 1.5, and 9.7 h, respectively, to meet the performance criterion. While the experimental setup was tested using S. aureus as an archetypical airborne pathogen, it can be readily adapted to test other types of pathogens and technologies. IMPORTANCE This study was designed to test the survival of airborne pathogens in the confined and shared space of a family automobile as well as to assess claims of devices marketed for in-car air decontamination. The basic experimental setup and the test protocols reported are versatile enough for work with all major types of airborne human pathogens and for testing a wide variety of air decontamination technologies. This study could also lay the foundation for a standardized test protocol for use by device makers as well as regulators for the registration of such devices. Copyright © 2017 American Society for Microbiology.

  7. Airborne Pathogens inside Automobiles for Domestic Use: Assessing In-Car Air Decontamination Devices Using Staphylococcus aureus as the Challenge Bacterium

    PubMed Central

    Zargar, Bahram; Wright, Kathryn E.; Rubino, Joseph R.; Ijaz, M. Khalid

    2017-01-01

    ABSTRACT Family cars represent ∼74% of the yearly global output of motorized vehicles. With a life expectancy of ∼8 decades in many countries, the average person spends >100 min daily inside the confined and often shared space of the car, with exposure to a mix of potentially harmful microbes. Can commercial in-car microbial air decontamination devices mitigate the risk? Three such devices (designated devices 1 to 3) with HEPA filters were tested in the modified passenger cabin (3.25 m3) of a four-door sedan housed within a biosafety level 3 containment facility. Staphylococcus aureus (ATCC 6538) was suspended in a soil load to simulate the presence of body fluids and aerosolized into the car's cabin with a 6-jet Collison nebulizer. A muffin fan (80 mm by 80 mm, with an output of 0.17 m3/min) circulated the air inside. Plates (150 mm diameter) of Trypticase soy agar (TSA), placed inside a programmable slit-to-agar sampler, were held at 36 ± 1°C for 18 to 24 h and examined for CFU. The input dose of the test bacterium, its rate of biological decay, and the log10 reductions by the test devices were analyzed. The arbitrarily set performance criterion was the time in hours a device took for a 3-log10 reduction in the level of airborne challenge bacterium. On average, the level of S. aureus challenge in the air varied between 4.2 log10 CFU/m3 and 5.5 log10 CFU/m3, and its rate of biological decay was −0.0213 ± 0.0021 log10 CFU/m3/min. Devices 1 to 3 took 2.3, 1.5, and 9.7 h, respectively, to meet the performance criterion. While the experimental setup was tested using S. aureus as an archetypical airborne pathogen, it can be readily adapted to test other types of pathogens and technologies. IMPORTANCE This study was designed to test the survival of airborne pathogens in the confined and shared space of a family automobile as well as to assess claims of devices marketed for in-car air decontamination. The basic experimental setup and the test protocols reported are versatile enough for work with all major types of airborne human pathogens and for testing a wide variety of air decontamination technologies. This study could also lay the foundation for a standardized test protocol for use by device makers as well as regulators for the registration of such devices. PMID:28389537

  8. Inactivation of Bacillus cereus by Na-chlorophyllin-based photosensitization on the surface of packaging.

    PubMed

    Luksiene, Z; Buchovec, I; Paskeviciute, E

    2010-11-01

    This study was focused on the possibility to inactivate food-borne pathogen Bacillus cereus by Na-chlorophyllin (Na-Chl)-based photosensitization in vitro and after attachment to the surface of packaging material. Bacillus cereus in vitro or attached to the packaging was incubated with Na-Chl (7·5×10(-8) to 7·5×10(-5) mol l(-1) ) for 2-60min in phosphate buffer saline. Photosensitization was performed by illuminating cells under a light with a λ of 400nm and an energy density of 20mW cm(-2) . The illumination time varied 0-5min and subsequently the total energy dose was 0-6J cm(-2) . The results show that B. cereus vegetative cells in vitro or attached to the surface of packaging after incubation with 7·5×10(-7) mol l(-1) Na-Chl and following illumination were inactivated by 7log. The photoinactivation of B. cereus spores in vitro by 4log required higher (7·5×10(-6) mol l(-1) ) Na-Chl concentration. Decontamination of packaging material from attached spores by photosensitization reached 5log at 7·5×10(-5) mol l(-1) Na-Chl concentration. Comparative analysis of different packaging decontamination treatments indicates that washing with water can diminish pathogen population on the surface by <1log, 100ppm Na-hypochlorite reduces the pathogens about 1·7log and 200ppm Na-hypochlorite by 2·2log. Meanwhile, Na-Chl-based photosensitization reduces bacteria on the surface by 4·2 orders of magnitude. Food-borne pathogen B. cereus could be effectively inactivated (7log) by Na-Chl-based photosensitization in vitro and on the surface of packaging material. Spores are more resistant than vegetative cells to photosensitization-based inactivation. Comparison of different surface decontamination treatments indicates that Na-Chl-based photosensitization is much more effective antibacterial tool than washing with water or 200ppm Na-hypochlorite. Our data support the idea that Na-Chl-based photosensitization has great potential for future application as an environment-friendly, nonthermal surface decontamination technique. © 2010 The Authors. Journal of Applied Microbiology © 2010 The Society for Applied Microbiology.

  9. Use of the Blom Tracheotomy Tube with Suction Inner Cannula to Decontaminate Microorganisms from the Subglottic Space. A Proof of Concept.

    PubMed

    Rabach, Lesley; Siegel, Mark D; Puchalski, Jonathan T; Towle, Dana; Follert, Michelle; Johnson, Kelsey M; Rademaker, Alfred W; Leder, Steven B

    2015-06-01

    Preventing pulmonary complications during mechanical ventilation via tracheotomy is a high priority. To investigate if the Blom tracheotomy tube with suction-above-the-cuff inner cannula reduced the quantity of normal flora and pathogens in supra- versus subglottic spaces. We enrolled 20 consecutive medical ICU adults requiring tracheostomy for mechanical ventilation in this proof-of-concept, prospective, single-center study. All participants received a Blom tracheotomy tube with suction-above-the-cuff inner cannula to decontaminate microorganisms from the supra- and subglottic spaces. Supra- and subglottic sputum samples were obtained for microbiologic analysis while an endotracheal tube was in place before tracheotomy and once per week for up to 4 weeks of mechanical ventilation after tracheotomy. Demographics, duration of endotracheal tube intubation, and duration of mechanical ventilation post-tracheotomy were recorded. There was a significant reduction for supraglottic (2.86 ± 1.11 [mean ± SD]) versus subglottic suction samples (2.48 ± 1.07) (paired t test, P = 0.048; Wilcoxon test, P = 0.045) when all data pairs for normal flora and pathogens were combined across times. There was a significant reduction of normal flora pooled across times in 19 data pairs for supraglottic (3.00 ± 1.05) versus subglottic suction samples (2.00 ± 0.94) (paired t test, P = 0.0004; Wilcoxon test, P = 0.0007). There was no significant reduction of pathogens pooled across times in 25 data pairs for supraglottic (2.76 ± 1.16) versus subglottic suction samples (2.84 ± 1.03) (paired t test, P = 0.75; Wilcoxon test, P = 0.83). Proof-of-concept was confirmed. The Blom tracheotomy tube with disposable suction-above-the-cuff inner cannula decontaminated microorganisms from the subglottic space when normal flora and pathogens were combined. Future research should investigate if decreased quantity of normal flora and pathogens in the subglottic space reduces the incidence of ventilator-associated pulmonary complications in critically ill patients requiring ongoing mechanical ventilation via tracheotomy.

  10. UV-C decontamination of hand-held tablet devices in the healthcare environment using the Codonics D6000™ disinfection system.

    PubMed

    Muzslay, M; Yui, S; Ali, S; Wilson, A P R

    2018-04-09

    Mobile phones and tablet computers may be contaminated with microorganisms and become a potential reservoir for cross-transmission of pathogens between healthcare workers and patients. There is no generally accepted guidance how to reduce contamination on mobile devices in healthcare settings. Our aim was to determine the efficacy of the Codonics D6000™ UV-C disinfection device. Daily disinfection reduced contamination on screens and on protective cases (test) significantly, but not all cases (control) could be decontaminated. The median aerobic colony count on the control and the test cases was 52 (IQR 33-89) cfu/25cm 2 and 22 (IQR 10.5-41) cfu/25cm 2 respectively before disinfection. Copyright © 2018. Published by Elsevier Ltd.

  11. Differential sensitivity of osteoblasts and bacterial pathogens to 405-nm light highlighting potential for decontamination applications in orthopedic surgery

    NASA Astrophysics Data System (ADS)

    Ramakrishnan, Praveen; Maclean, Michelle; MacGregor, Scott J.; Anderson, John G.; Grant, M. Helen

    2014-10-01

    Healthcare associated infections pose a major threat to patients admitted to hospitals and infection rates following orthopedic arthroplasty surgery are as high as 4%. A 405-nm high-intensity narrow spectrum light has been proven to reduce environmental contamination in hospital isolation rooms, and there is potential to develop this technology for application in arthroplasty surgery. Cultured rat osteoblasts were exposed to varying light intensities and it was found that exposures of up to a dose of 36 J/cm2 had no significant effect on cell viability [3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide assay], function (alkaline phosphatase activity), and proliferation rate (BrdU cell proliferation assay). High irradiance exposures (54 J/cm2) significantly affected the cell viability indicating that the effects of 405-nm light on osteoblasts are dose dependent. Additionally, exposure of a variety of clinically related bacteria to a dose of 36 J/cm2 resulted in up to 100% kill. These results demonstrating the differential sensitivity of osteoblasts and bacteria to 405-nm light are an essential step toward developing the technique for decontamination in orthopedic surgery.

  12. Lytic bacteriophages

    PubMed Central

    Sharma, Manan

    2013-01-01

    Foodborne illnesses resulting from the consumption of produce commodities contaminated with enteric pathogens continue to be a significant public health issue. Lytic bacteriophages may provide an effective and natural intervention to reduce bacterial pathogens on fresh and fresh-cut produce commodities. The use of multi-phage cocktails specific for a single pathogen has been most frequently assessed on produce commodities to minimize the development of bacteriophage insensitive mutants (BIM) in target pathogen populations. Regulatory approval for the use of several lytic phage products specific for bacterial pathogens such as Escherichia coli O157:H7, Salmonella spp. and Listeria monocytogenes in foods and on food processing surfaces has been granted by various agencies in the US and other countries, possibly allowing for the more widespread use of bacteriophages in the decontamination of fresh and minimally processed produce. Research studies have shown lytic bacteriophages specific for E. coli O157:H7, Salmonella spp. and Listeria monocytogenes have been effective in reducing pathogen populations on leafy greens, sprouts and tomatoes. PMID:24228223

  13. Fundamental Studies of Transient, Atmospheric-Pressure, Small-Scale Plasmas

    DTIC Science & Technology

    2017-01-23

    e.g. plasma brush) were explored for surface decontamination against pathogenic bacteria and biofilms , as well as for treatment of cervical cancer , in...pressure plasma jets and jet arrays (e.g. plasma brush) were explored for surface decontamination against pathogenic bacteria and biofilms , as well as...for treatment of cervical cancer , in vitro. 4) Other studies involving portable nanosecond pulsed power generation based gas switches or

  14. Analysis of sepsis in allogeneic bone marrow transplant recipients: a single-center study.

    PubMed

    Mitsui, Hideki; Karasuno, Takahiro; Santo, Taisuke; Fukushima, Kentaro; Matsunaga, Hitomi; Nakamura, Hiroyuki; Hiraoka, Akira

    2003-09-01

    We reviewed the records of 235 consecutive recipients of allogeneic bone marrow transplantation (allo-BMT) at our center between February 1983 and October 2000. Sepsis occurred in 25 patients (10.6%) at a median of 10 days (range, 1-280 days) after BMT. Five of the 25 patients (20%) died of sepsis. Pathogens isolated from blood culture were gram-positive cocci in 19 patients, gram-negative rods in 7, fungi in 2, and others in 1 patient. Two pathogens were detected concomitantly in 4 patients. Univariate analysis revealed that risk factors for sepsis were selective gut decontamination using lomefloxacin hydrochloride and nystatin, an unrelated donor, HLA mismatched BMT, and stomatitis. Multivariate logistic regression analysis revealed that an unrelated donor was the only significant independent risk factor, with a relative risk of 5.432. In 12 of 25 patients with sepsis, the pathogens of sepsis were sensitive to antibiotics used for gut decontamination. Selective gut decontamination significantly increased the incidence of sepsis, especially that with gram-positive cocci, but not the mortality rate of sepsis, compared with total gut decontamination using vancomycin. We also found a significant relationship between pathogens isolated from blood culture and those isolated from surveillance cultures of stool, urine, and gargled water in the period before sepsis occurred. The present study revealed an independent risk factor for sepsis (unrelated donor), the feasibility of selective gut decontamination, and the importance of surveillance culture.

  15. Effective photosensitization-based inactivation of Gram (-) food pathogens and molds using the chlorophyllin-chitosan complex: towards photoactive edible coatings to preserve strawberries.

    PubMed

    Buchovec, Irina; Lukseviciute, Viktorija; Marsalka, Arunas; Reklaitis, Ignas; Luksiene, Zivile

    2016-04-01

    This study is focused on the novel approaches to enhance the inactivation of the Gram (-) food pathogen Salmonella enterica and harmful molds in vitro and on the surface of strawberries using the chlorophyllin-chitosan complex. Salmonella enterica (∼1 × 10(7) CFU mL(-1)) was incubated with chlorophyllin 1.5 × 10(-5) M (Chl, food additive), chitosan 0.1% (CHS, food supplement) or the chlorophyllin-chitosan complex (1.5 × 10(-5) M Chl-0.1% CHS) and illuminated with visible light (λ = 405 nm, light dose 38 J cm(-2)) in vitro. Chlorophyllin (Chl)-based photosensitization inactivated Salmonella just by 1.8 log. Chitosan (CHS) alone incubated for 2 h with Salmonella reduced viability 2.15 log, whereas photoactivated Chl-CHS diminished bacterial viability by 7 log. SEM images indicate that the Chl-CHS complex under these experimental conditions covered the entire bacterial surface. Significant cell membrane disintegration was the main lethal injury induced in Gram (-) bacteria by this treatment. Analysis of strawberry decontamination from surface-inoculated Salmonella indicated that photoactivated Chl-CHS (1.5 × 10(-5) M Chl-0.1% CHS, 30 min incubation, light dose 38 J cm(-2)) coatings diminished the pathogen population on the surface of strawberries by 2.2 log. Decontamination of strawberries from naturally distributed yeasts/molds revealed that chitosan alone reduced the population of yeasts/molds just by 0.4 log, Chl-based photosensitization just by 0.9 log, whereas photoactivated Chl-CHS coatings reduced yeasts/molds on the surface of strawberries by 1.4 log. Electron paramagnetic resonance spectroscopy confirmed that no additional photosensitization-induced free radicals have been found in the strawberry matrix. Visual quality (color, texture) of the treated strawberries was not affected either. In conclusion, photoactive Chl-CHS exhibited strong antimicrobial action against more resistant to photosensitization Gram (-) Salmonella enterica in comparison with Gram (+) bacteria in vitro. It reduced significantly the viability of strawberry surface-attached yeasts/molds and inoculated Salmonella without any negative impact on the visual quality of berries. Experimental data support the idea that photoactivated Chl-CHS can be a useful tool for the future development of edible photoactive antimicrobial coatings which can preserve strawberries and prolong their shelf-life according to requirements of "clean green technology".

  16. Role of extracellular matrix protein CabA in resistance of Vibrio vulnificus biofilms to decontamination strategies.

    PubMed

    Park, Jin Hwan; Lee, Byungho; Jo, Youmi; Choi, Sang Ho

    2016-11-07

    Biofilms are recalcitrant and raise safety problems in the food industry. In this study, the role of CabA, an extracellular matrix protein, in the resistance of the biofilms of Vibrio vulnificus, a foodborne pathogen, to decontamination strategies was investigated. Biofilms of the cabA mutant revealed reduced resistance to detachment by vibration and disinfection by sodium hypochlorite compared to the biofilms of the parental wild type in vitro. The reduced resistance of the cabA mutant biofilms was complemented by introducing a recombinant cabA, indicating that the reduced resistance of the cabA mutant biofilms is caused by the inactivation of cabA. The expression of cabA was induced in cells bound to oyster, the primary vehicle of the pathogen. The cabA mutant biofilms on oyster are defective in biomass and resistance to detachment and disinfection. The bacterial cells in the wild-type biofilms are clustered by filaments which are not apparent in the cabA mutant biofilms. The combined results indicated that CabA contributes to the structural integrity of V. vulnificus biofilms possibly by forming filaments in the matrix and thus rendering the biofilms robust, suggesting that CabA could be a target to control V. vulnificus biofilms on oyster. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Ultraviolet-ozone treatment reduces levels of disease-associated prion protein and prion infectivity

    USGS Publications Warehouse

    Johnson, C.J.; Gilbert, P.; McKenzie, D.; Pedersen, J.A.; Aiken, Judd M.

    2009-01-01

    Background. Transmissible spongiform encephalopathies (TSEs) are a group of fatal neurodegenerative diseases caused by novel infectious agents referred to as prions. Prions appear to be composed primarily, if not exclusively, of a misfolded isoform of the cellular prion protein. TSE infectivity is remarkably stable and can resist many aggressive decontamination procedures, increasing human, livestock and wildlife exposure to TSEs. Findings. We tested the hypothesis that UV-ozone treatment reduces levels of the pathogenic prion protein and inactivates the infectious agent. We found that UV-ozone treatment decreased the carbon and prion protein content in infected brain homogenate to levels undetectable by dry-ashing carbon analysis or immunoblotting, respectively. After 8 weeks of ashing, UV-ozone treatment reduced the infectious titer of treated material by a factor of at least 105. A small amount of infectivity, however, persisted despite UV-ozone treatment. When bound to either montmorillonite clay or quartz surfaces, PrPTSE was still susceptible to degradation by UV-ozone. Conclusion. Our findings strongly suggest that UV-ozone treatment can degrade pathogenic prion protein and inactivate prions, even when the agent is associated with surfaces. Using larger UV-ozone doses or combining UV-ozone treatment with other decontaminant methods may allow the sterilization of TSE-contaminated materials. ?? 2009 Aiken et al; licensee BioMed Central Ltd.

  18. Estimating the probability of an extinction or major outbreak for an environmentally transmitted infectious disease.

    PubMed

    Lahodny, G E; Gautam, R; Ivanek, R

    2015-01-01

    Indirect transmission through the environment, pathogen shedding by infectious hosts, replication of free-living pathogens within the environment, and environmental decontamination are suspected to play important roles in the spread and control of environmentally transmitted infectious diseases. To account for these factors, the classic Susceptible-Infectious-Recovered-Susceptible epidemic model is modified to include a compartment representing the amount of free-living pathogen within the environment. The model accounts for host demography, direct and indirect transmission, replication of free-living pathogens in the environment, and removal of free-living pathogens by natural death or environmental decontamination. Based on the assumptions of the deterministic model, a continuous-time Markov chain model is developed. An estimate for the probability of disease extinction or a major outbreak is obtained by approximating the Markov chain with a multitype branching process. Numerical simulations illustrate important differences between the deterministic and stochastic counterparts, relevant for outbreak prevention, that depend on indirect transmission, pathogen shedding by infectious hosts, replication of free-living pathogens, and environmental decontamination. The probability of a major outbreak is computed for salmonellosis in a herd of dairy cattle as well as cholera in a human population. An explicit expression for the probability of disease extinction or a major outbreak in terms of the model parameters is obtained for systems with no direct transmission or replication of free-living pathogens.

  19. An evaluation of selected methods for the decontamination of cattle hides prior to skinning.

    PubMed

    Small, A; Wells-Burr, B; Buncic, S

    2005-02-01

    The effectiveness of different decontamination treatments in reducing microbial loads on cattle hides was assessed. The 10-s hide treatments were conducted using a wet-and-dry vacuum cleaner filled with one of the liquids (heated to 50 °C) indicated below, followed or not by 10-min drying in the air. Also, the hide was clipped, followed or not by 10-s singeing using a hand-held blowtorch. Before and after each decontamination treatment, the hide was sampled (100 cm(2) areas) by a sponge-swabbing method to compare the total viable counts of bacteria (TVC). The largest bacterial reduction (P<0.001; 2.31log(10) cfu/cm(2)) was achieved by singeing of previously clipped hide. Treatment of hide with a food industry sanitizer solution (10% Betane Plus) resulted in significant reductions of 1.80 (P<0.001) and 1.98log(10) cfu/cm(2) (P<0.001) without and with subsequent drying, respectively. Treatment of hide with a food industry disinfectant (P3-Topactive DES) significantly reduced TVC by 0.97 (P<0.001) and 1.18log(10) cfu/cm(2) (P<0.001) without and with subsequent drying, respectively. Treatments of hide with water alone or with a food-safe detergent solution (Formula 963B), or hide clipping alone, did not produce significant decontamination effects. Since hide contamination is associated with microbial contamination of the carcasses, the results indicate that post-killing/pre-skinning hide decontamination (used alone, or in combination with carcass decontamination) has a potential to improve microbial meat safety. Nevertheless, further research is required to optimise the efficacy of these treatments in the reduction of specific pathogens under commercial conditions.

  20. Decontamination of High-risk Animal and Zoonotic Pathogens

    PubMed Central

    Menrath, Andrea; Tomuzia, Katharina; Braeunig, Juliane; Appel, Bernd

    2013-01-01

    Preparedness for the decontamination of affected environments, premises, facilities, and products is one prerequisite for an immediate response to an animal disease outbreak. Various information sources provide recommendations on how to proceed in an outbreak situation to eliminate biological contaminants and to stop the spread of the disease. In order to facilitate the identification of the right decontamination strategy, we present an overview of relevant references for a collection of pathogenic agents. The choice of pathogens is based on a survey of lists containing highly pathogenic agents and/or biological agents considered to be potential vehicles for deliberate contamination of food, feed, or farm animals. European legislation and guidelines from national and international institutions were screened to find decontamination protocols for each of the agents. Identified recommendations were evaluated with regard to their area of application, which could be facilities and equipment, wastes, food, and other animal products. The requirements of a disinfectant for large-scale incidents were gathered, and important characteristics (eg, inactivating spectrum, temperature range, toxicity to environment) of the main recommended disinfectants were summarized to assist in the choice of a suitable and efficient approach in a crisis situation induced by a specific high-risk animal or zoonotic pathogen. The literature search revealed numerous relevant recommendations but also legal gaps for certain diseases, such as Q fever or brucellosis, and legal difficulties for the use of recommended disinfectants. A lack of information about effective disinfectants was identified for some agents. PMID:23971795

  1. Decontamination of high-risk animal and zoonotic pathogens.

    PubMed

    Frentzel, Hendrik; Menrath, Andrea; Tomuzia, Katharina; Braeunig, Juliane; Appel, Bernd

    2013-09-01

    Preparedness for the decontamination of affected environments, premises, facilities, and products is one prerequisite for an immediate response to an animal disease outbreak. Various information sources provide recommendations on how to proceed in an outbreak situation to eliminate biological contaminants and to stop the spread of the disease. In order to facilitate the identification of the right decontamination strategy, we present an overview of relevant references for a collection of pathogenic agents. The choice of pathogens is based on a survey of lists containing highly pathogenic agents and/or biological agents considered to be potential vehicles for deliberate contamination of food, feed, or farm animals. European legislation and guidelines from national and international institutions were screened to find decontamination protocols for each of the agents. Identified recommendations were evaluated with regard to their area of application, which could be facilities and equipment, wastes, food, and other animal products. The requirements of a disinfectant for large-scale incidents were gathered, and important characteristics (eg, inactivating spectrum, temperature range, toxicity to environment) of the main recommended disinfectants were summarized to assist in the choice of a suitable and efficient approach in a crisis situation induced by a specific high-risk animal or zoonotic pathogen. The literature search revealed numerous relevant recommendations but also legal gaps for certain diseases, such as Q fever or brucellosis, and legal difficulties for the use of recommended disinfectants. A lack of information about effective disinfectants was identified for some agents.

  2. Effectiveness of ultraviolet devices and hydrogen peroxide systems for terminal room decontamination: Focus on clinical trials.

    PubMed

    Weber, David J; Rutala, William A; Anderson, Deverick J; Chen, Luke F; Sickbert-Bennett, Emily E; Boyce, John M

    2016-05-02

    Over the last decade, substantial scientific evidence has accumulated that indicates contamination of environmental surfaces in hospital rooms plays an important role in the transmission of key health care-associated pathogens (eg, methicillin-resistant Staphylococcus aureus, vancomycin-resistant enterococci, Clostridium difficile, Acinetobacter spp). For example, a patient admitted to a room previously occupied by a patient colonized or infected with one of these pathogens has a higher risk for acquiring one of these pathogens than a patient admitted to a room whose previous occupant was not colonized or infected. This risk is not surprising because multiple studies have demonstrated that surfaces in hospital rooms are poorly cleaned during terminal cleaning. To reduce surface contamination after terminal cleaning, no touch methods of room disinfection have been developed. This article will review the no touch methods, ultraviolet light devices, and hydrogen peroxide systems, with a focus on clinical trials which have used patient colonization or infection as an outcome. Multiple studies have demonstrated that ultraviolet light devices and hydrogen peroxide systems have been shown to inactivate microbes experimentally plated on carrier materials and placed in hospital rooms and to decontaminate surfaces in hospital rooms naturally contaminated with multidrug-resistant pathogens. A growing number of clinical studies have demonstrated that ultraviolet devices and hydrogen peroxide systems when used for terminal disinfection can reduce colonization or health care-associated infections in patients admitted to these hospital rooms. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  3. Effect of poultry decontaminants concentration on growth kinetics for pathogenic and spoilage bacteria.

    PubMed

    del Río, Elena; González de Caso, Beatriz; Prieto, Miguel; Alonso-Calleja, Carlos; Capita, Rosa

    2008-10-01

    Various chemical compounds are currently under review for final approval as poultry decontaminants in the European Union (EU). Concentration is among the factors considered by the EU authorities in the evaluation of these treatments. The aim of this research was to compare the growth parameters for pathogenic and spoilage bacteria in presence of high and low concentrations of poultry decontaminants to assess whether such treatments could involve a potential sanitary risk for consumers. Growth curves for Salmonella enterica serotype Enteritidis, Listeria monocytogenes, Pseudomonas fluorescens and Brochothrix thermosphacta were obtained at different levels of trisodium phosphate (TSP; 1.74%; 0.58%), acidified sodium chlorite (ASC; 210 ppm; 70 ppm) and citric acid (CA; 0.27%; 0.09%). The modified Gompertz equation was used as primary model to fit observed data. ASC and TSP were the most effective compounds in increasing lag phase (L) and reducing maximum growth rate (mu) in Gram-negative bacteria. Gram-positive bacteria were more influenced by CA. At high TSP levels, mu for Salmonella decreased. Low TSP levels increased mu for Salmonella and Listeria relative to control samples. In presence of 0.27% CA, Brochothrix showed the highest L and the lowest mu among strains tested. These results suggest that low TSP and high CA concentrations could favour the outgrowth of pathogenic bacteria (e.g. Salmonella) relative to spoilage bacteria, rending these treatments potentially dangerous for consumers. The findings of this study may be useful to the EU authorities and meat processors in their efforts to select adequate treatments for control of bacteria on poultry.

  4. Efficacy of two hydrogen peroxide vapour aerial decontamination systems for enhanced disinfection of meticillin-resistant Staphylococcus aureus, Klebsiella pneumoniae and Clostridium difficile in single isolation rooms.

    PubMed

    Ali, S; Muzslay, M; Bruce, M; Jeanes, A; Moore, G; Wilson, A P R

    2016-05-01

    Hydrogen peroxide vapour (HPV) disinfection systems are being used to reduce patients' exposure to hospital pathogens in the environment. HPV whole-room aerial disinfection systems may vary in terms of operating concentration and mode of delivery. To assess the efficacy of two HPV systems (HPS1 and HPS2) for whole-room aerial disinfection of single isolation rooms (SIRs). Ten SIRs were selected for manual terminal disinfection after patient discharge. Test coupons seeded with biological indicator (BI) organisms [∼10(6) colony-forming units (cfu) of meticillin-resistant Staphylococcus aureus (MRSA) or Klebsiella pneumoniae, or ∼10(5)cfu Clostridium difficile 027 spores] prepared in a soil challenge were placed at five locations per room. For each cycle, 22 high-frequency-touch surfaces in SIRs were sampled with contact plates (∼25cm(2)) before and after HPV decontamination, and BIs were assayed for the persistence of pathogens. Approximately 95% of 214 sites were contaminated with bacteria after manual terminal disinfection, with high numbers present on the SIR floor (238.0-352.5cfu), bed control panel (24.0-33.5cfu), and nurse call button (21.5-7.0cfu). Enhanced disinfection using HPV reduced surface contamination to low levels: HPS1 [0.25cfu, interquartile range (IQR) 0-1.13] and HPS2 (0.5cfu, IQR 0-2.0). Both systems demonstrated similar turnaround times (∼2-2.5h), and no differences were observed in the efficacy of the two systems against BIs (C. difficile ∼5.1log10 reduction; MRSA/K. pneumoniae ∼6.3log10 reduction). Despite different operating concentrations of hydrogen peroxide, MRSA persisted on 27% of coupons after HPV decontamination. Enhanced disinfection with HPV reduces surface contamination left by manual terminal cleaning, minimizing the risks of cross-contamination. The starting concentration and mode of delivery of hydrogen peroxide may not improve the efficacy of decontamination in practice, and therefore the choice of HPV system may be based upon other considerations such as cost, convenience and logistics. Copyright © 2016. Published by Elsevier Ltd.

  5. Airborne Infectious Agents and Other Pollutants in Automobiles for Domestic Use: Potential Health Impacts and Approaches to Risk Mitigation

    PubMed Central

    Zargar, Bahram; Rubino, Joseph R.

    2016-01-01

    The world total of passenger cars is expected to go from the current one billion to >2.5 billion by 2050. Cars for domestic use account for ~74% of the world's yearly production of motorized vehicles. In North America, ~80% of the commuters use their own car with another 5.6% travelling as passengers. With the current life-expectancy of 78.6 years, the average North American spends 4.3 years driving a car! This equates to driving 101 minutes/day with a lifetime driving distance of nearly 1.3 million km inside the confined and often shared space of the car with exposure to a mix of potentially harmful pathogens, allergens, endotoxins, particulates, and volatile organics. Such risks may increase in proportion to the unprecedented upsurge in the numbers of family cars globally. Though new technologies may reduce the levels of air pollution from car exhausts and other sources, they are unlikely to impact our in-car exposure to pathogens. Can commercial in-car air decontamination devices reduce the risk from airborne infections and other pollutants? We lack scientifically rigorous protocols to verify the claims of such devices. Here we discuss the essentials of a customized aerobiology facility and test protocols to assess such devices under field-relevant conditions. PMID:28042302

  6. Airborne Infectious Agents and Other Pollutants in Automobiles for Domestic Use: Potential Health Impacts and Approaches to Risk Mitigation.

    PubMed

    Sattar, Syed A; Wright, Kathryn E; Zargar, Bahram; Rubino, Joseph R; Ijaz, M Khalid

    2016-01-01

    The world total of passenger cars is expected to go from the current one billion to >2.5 billion by 2050. Cars for domestic use account for ~74% of the world's yearly production of motorized vehicles. In North America, ~80% of the commuters use their own car with another 5.6% travelling as passengers. With the current life-expectancy of 78.6 years, the average North American spends 4.3 years driving a car! This equates to driving 101 minutes/day with a lifetime driving distance of nearly 1.3 million km inside the confined and often shared space of the car with exposure to a mix of potentially harmful pathogens, allergens, endotoxins, particulates, and volatile organics. Such risks may increase in proportion to the unprecedented upsurge in the numbers of family cars globally. Though new technologies may reduce the levels of air pollution from car exhausts and other sources, they are unlikely to impact our in-car exposure to pathogens. Can commercial in-car air decontamination devices reduce the risk from airborne infections and other pollutants? We lack scientifically rigorous protocols to verify the claims of such devices. Here we discuss the essentials of a customized aerobiology facility and test protocols to assess such devices under field-relevant conditions.

  7. Evaluation of the PotoClean® decontamination technology for reprocessing of water supply lines in dental units during routine work

    PubMed Central

    Kramer, Axel; Koburger, Torsten; Taube, Lisa-Dorothea; Menzel, Michael; Meyer, Georg; Assadian, Ojan

    2012-01-01

    Background: A frequent problem in dental units is the microbial contamination of water and biofilm formation in the water supply lines. After random identification of a bacterial contaminated dental unit (310 cfu/ml) in a practise with 3 dental units we implemented the present study to evaluate the efficacy of the PotoClean® technology, based on anodic oxidation. Method: The efficacy of a regular low concentrated permanent decontamination (1 mg Cl/L) with an additional intensive decontamination by PotoClean® (three times 20 mg Cl/ml for 2 h) on three dental units was tested over 7 months. Microbial contamination, total chlorine concentration and redox potential have been analyzed. Dental unit A and B was 15 years old, unit C 5 years. Results: After 3 intensive decontaminations, in dental unit A and B the number of bacteria and moulds could be reduced less than 7 d. Thereafter the bacteria counts increased again during the subsequent 7 month period and the amount of moulds was with some exceptions 300 cfu/ml, although PotoClean® was constantly added in the system (1 mg Cl/L). After further 7.5 month only with low concentrated permanent disinfection (1 mg Cl/L) both units were successful decontaminated. Dental unit C represented an object which was easier to decontaminate because of the advanced construction (prevention of water stagnation) and the shorter useful life. At the beginning of the decontamination it was no bacterial contamination, but moulds were contained (300 cfu/ml). Already after the first intensive decontamination, no further bacteria and moulds could be detected. Discussion: An important factor for the efficacy of PotoClean® was the age of the units and their construction. For a new generation of dental units PotoClean® was effective during the whole period of monitoring. For two old types of dental unit with massive biofilm development the successful decontamination needed more than 7 month. Conclusion: The PotoClean® technology has resulted in even old-type turbines with intensive biofilm formation to complete decontamination. In a recent turbine design already after the first intensive decontamination with PotoClean® and its continuous use (1 mg Cl/L) no more contamination by bacteria and moulds were detectable. PMID:22558044

  8. Evaluation of the PotoClean(®) decontamination technology for reprocessing of water supply lines in dental units during routine work.

    PubMed

    Kramer, Axel; Koburger, Torsten; Taube, Lisa-Dorothea; Menzel, Michael; Meyer, Georg; Assadian, Ojan

    2012-01-01

    A frequent problem in dental units is the microbial contamination of water and biofilm formation in the water supply lines. After random identification of a bacterial contaminated dental unit (310 cfu/ml) in a practise with 3 dental units we implemented the present study to evaluate the efficacy of the PotoClean(®) technology, based on anodic oxidation. The efficacy of a regular low concentrated permanent decontamination (1 mg Cl/L) with an additional intensive decontamination by PotoClean(®) (three times 20 mg Cl/ml for 2 h) on three dental units was tested over 7 months. Microbial contamination, total chlorine concentration and redox potential have been analyzed. Dental unit A and B was 15 years old, unit C 5 years. After 3 intensive decontaminations, in dental unit A and B the number of bacteria and moulds could be reduced less than 7 d. Thereafter the bacteria counts increased again during the subsequent 7 month period and the amount of moulds was with some exceptions 300 cfu/ml, although PotoClean(®) was constantly added in the system (1 mg Cl/L). After further 7.5 month only with low concentrated permanent disinfection (1 mg Cl/L) both units were successful decontaminated. Dental unit C represented an object which was easier to decontaminate because of the advanced construction (prevention of water stagnation) and the shorter useful life. At the beginning of the decontamination it was no bacterial contamination, but moulds were contained (300 cfu/ml). Already after the first intensive decontamination, no further bacteria and moulds could be detected. An important factor for the efficacy of PotoClean(®) was the age of the units and their construction. For a new generation of dental units PotoClean(®) was effective during the whole period of monitoring. For two old types of dental unit with massive biofilm development the successful decontamination needed more than 7 month. The PotoClean(®) technology has resulted in even old-type turbines with intensive biofilm formation to complete decontamination. In a recent turbine design already after the first intensive decontamination with PotoClean(®) and its continuous use (1 mg Cl/L) no more contamination by bacteria and moulds were detectable.

  9. Potassium permanganate cleansing is an effective sanitary method for the reduction of bacterial bioload on raw Coriandrum sativum.

    PubMed

    Subramanya, Supram Hosuru; Pai, Vasudha; Bairy, Indira; Nayak, Niranjan; Gokhale, Shishir; Sathian, Brijesh

    2018-02-13

    Raw vegetables including flowers, leaves, stems, and roots are important carriers of food borne pathogens. We evaluated the bacteriological contamination of unwashed coriander leaves, and effectiveness of cleansing with 0.1% potassium permanganate solution as decontamination method. Significant bacterial contamination including pathogens like Salmonella species and Aeromonas species were isolated from unwashed coriander leaves. Decontamination with 0.1% potassium permanganate was found to be more effective than three steps wash with sterile water.

  10. Efficacy of liquid and foam decontamination technologies for chemical warfare agents on indoor surfaces.

    PubMed

    Love, Adam H; Bailey, Christopher G; Hanna, M Leslie; Hok, Saphon; Vu, Alex K; Reutter, Dennis J; Raber, Ellen

    2011-11-30

    Bench-scale testing was used to evaluate the efficacy of four decontamination formulations on typical indoor surfaces following exposure to the liquid chemical warfare agents sarin (GB), soman (GD), sulfur mustard (HD), and VX. Residual surface contamination on coupons was periodically measured for up to 24h after applying one of four selected decontamination technologies [0.5% bleach solution with trisodium phosphate, Allen Vanguard Surface Decontamination Foam (SDF™), U.S. military Decon Green™, and Modec Inc. and EnviroFoam Technologies Sandia Decontamination Foam (DF-200)]. All decontamination technologies tested, except for the bleach solution, performed well on nonporous and nonpermeable glass and stainless-steel surfaces. However, chemical agent residual contamination typically remained on porous and permeable surfaces, especially for the more persistent agents, HD and VX. Solvent-based Decon Green™ performed better than aqueous-based bleach or foams on polymeric surfaces, possibly because the solvent is able to penetrate the polymer matrix. Bleach and foams out-performed Decon Green for penetrating the highly polar concrete surface. Results suggest that the different characteristics needed for an ideal and universal decontamination technology may be incompatible in a single formulation and a strategy for decontaminating a complex facility will require a range of technologies. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. Efficacy of UV, acidified sodium hypochlorite, and mild heat for decontamination of surface and infiltrated Escherichia coli O157:H7 on green onions and baby spinach.

    PubMed

    Durak, M Zeki; Churey, John J; Worobo, Randy W

    2012-07-01

    Produce-associated foodborne illnesses outbreaks have highlighted the need for more effective decontamination methods to ensure the safety of fresh produce. The main objective of this study was to evaluate the individual and combined efficacies of germicidal UV light (12.5 to 500 mJ/cm(2)), acidified sodium hypochlorite (ASC 10 to 200 ppm), and mild heat (40 to 50°C) for decontaminating green onions and baby spinach infected with Escherichia coli O157:H7. Samples were inoculated by spot and dip inoculation methods to mimic surface and infiltrated E. coli O157:H7 contamination, respectively. In green onions and baby spinach, the individual efficacies of UV, ASC, and mild-heat treatments varied based on the produce type and contamination method. Following analysis of the efficacies of the single treatments, a combined treatment with 125 mJ/cm(2) UV and 200 ppm of ASC at 50°C was selected for spot-inoculated green onions, and a combined treatment with 125 mJ/cm(2) UV and 200 ppm of ASC at 20°C was selected for spot- and dip-inoculated baby spinach. While a >5-log reduction was achieved with the combination treatment for spot-inoculated green onions with an initial contamination level of 7.2 log CFU per spot, the same treatment reduced E. coli O157:H7 populations below the detection limit (<1 log) on green onions spot inoculated at a lower contamination level (4.3 log CFU per spot). On spot- and dip-inoculated baby spinach, the combined treatment reduced E. coli O157:H7 populations by 2.8 log CFU per spot and 2.6 log CFU/g, respectively. The combined treatment of 500 mJ/cm(2) UV and 200 ppm of ASC at 50°C selected for the decontamination of dip-inoculated green onions resulted in a 2.2-log CFU/g reduction. These findings suggest that when foodborne pathogens contaminate produce and subsequently infiltrate, attach to, or become localized into protected areas, the individual or combined applications of UV, ASC, and mild-heat treatments have limited decontamination efficacies on both green onions and baby spinach (<3 log). However, treatments combining UV, ASC, and mild heat could be a promising application for reducing pathogen populations (>5 log) on E. coli O157:H7 surface-contaminated green onions. This study also highlights the importance of developing and optimizing produce-specific decontamination methods to ensure the safety of fresh produce commodities.

  12. Application and Removal of Strippable Coatings via Remote Platform - 13133

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shoffner, P.; Lagos, L.; Maggio, S.

    2013-07-01

    Florida International University's (FIU's) Applied Research Center is currently supporting the Department of Energy (DOE) Environmental Management Office of D and D and Facility Engineering program. FIU is supporting DOE's initiative to improve safety, reduce technical risks, and limit uncertainty within D and D operations by identifying technologies suitable to meet specific facility D and D requirements, assessing the readiness of those technologies for field deployment, and conducting feasibility studies and technology demonstrations of selected technologies and working with technology vendors to optimize the design of their current technologies to accomplish dangerous and demanding tasks during D and D operations.more » To meet one identified technology gap challenge for a technology to remotely apply strippable coatings, fixatives and decontamination gels, FIU identified and performed an initial demonstration of an innovative remote fixative sprayer platform from International Climbing Machines (ICM). The selected technology was demonstrated spraying fixative products at the hot cell mockup facility at the Applied Research Center at FIU in November 2008 under cold (non-radioactive) conditions. The remotely controlled platform was remotely operated and entered the facility and sprayed a fixative onto horizontal and vertical surfaces. Based on the initial FIU demonstration and the specific technical requirements identified at the DOE facilities, a follow-up demonstration was expanded to include strippable coatings and a decontamination gel, which was demonstrated in June 2010 at the ICM facility in Ithaca, NY. This second technology evaluation documented the ability of the remote system to spray the selected products on vertical stainless steel and concrete surfaces to a height of 3 meters (10 feet) and to achieve sufficient coverage and product thickness to promote the ability to peel/remove the strippable coatings and decontamination gel. The next challenge was to determine if a remote platform could be used to remove the strippable coatings and decontamination gels. In 2012, FIU worked with the technology provider, ICM, to conduct feasibility and trade studies to identify the requirements for the remote removal of strippable coatings or decontamination gels using the existing remote controlled platform. (authors)« less

  13. Conversion of transuranic waste to low level waste by decontamination: a technical and economic evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Allen, R.P.; Hazelton, R.F.

    1984-12-01

    A study was conducted to evaluate the technical and economic feasibility of using in-situ decontamination techniques to convert glove boxes and other large TRU-contaminated components directly into LLW. The results of the technical evaluation indicate that in-situ decontamination of these types of components to non-TRU levels is technically feasible. Applicable decontamination techniques include electropolishing, hand scrubbing, chemical washes/sprays, strippable coatings and Freon spray-cleaning. The removal of contamination from crevices and other holdup areas remains a problem, but may be solved through further advances in decontamination technology. Also, the increase in the allowable maximum TRU level from 10 nCi/g to 100more » nCi/g as defined in DOE Order 5820.2 reduces the removal requirement and facilitates measurement of the remaining quantities. The major emphasis of the study was on a cost/benefit evaluation that included a review and update of previous analyses and evaluations of TRU-waste volume reduction and conversion options. The results of the economic evaluation show, for the assumptions used, that there is a definite cost incentive to size reduce large components, and that decontamination of sectioned material has become cost competitive with the size reduction options. In-situ decontamination appears to be the lowest cost option when based on routine-type operations conducted by well-trained and properly equipped personnel. 16 references, 1 figure, 7 tables.« less

  14. Low-Temperature Decontamination with Hydrogen Peroxide or Chlorine Dioxide for Space Applications

    PubMed Central

    Macken, S.; Giri, K.; Walker, J. T.; Bennett, A. M.

    2012-01-01

    The currently used microbial decontamination method for spacecraft and components uses dry-heat microbial reduction at temperatures of >110°C for extended periods to prevent the contamination of extraplanetary destinations. This process is effective and reproducible, but it is also long and costly and precludes the use of heat-labile materials. The need for an alternative to dry-heat microbial reduction has been identified by space agencies. Investigations assessing the biological efficacy of two gaseous decontamination technologies, vapor hydrogen peroxide (Steris) and chlorine dioxide (ClorDiSys), were undertaken in a 20-m3 exposure chamber. Five spore-forming Bacillus spp. were exposed on stainless steel coupons to vaporized hydrogen peroxide and chlorine dioxide gas. Exposure for 20 min to vapor hydrogen peroxide resulted in 6- and 5-log reductions in the recovery of Bacillus atrophaeus and Geobacillus stearothermophilus, respectively. However, in comparison, chlorine dioxide required an exposure period of 60 min to reduce both B. atrophaeus and G. stearothermophilus by 5 logs. Of the three other Bacillus spp. tested, Bacillus thuringiensis proved the most resistant to hydrogen peroxide and chlorine dioxide with D values of 175.4 s and 6.6 h, respectively. Both low-temperature decontamination technologies proved effective at reducing the Bacillus spp. tested within the exposure ranges by over 5 logs, with the exception of B. thuringiensis, which was more resistant to both technologies. These results indicate that a review of the indicator organism choice and loading could provide a more appropriate and realistic challenge for the sterilization procedures used in the space industry. PMID:22492450

  15. In-situ generation of chlorine dioxide for surface decontamination of produce

    USDA-ARS?s Scientific Manuscript database

    Fruits and vegetables, particularly fresh-cut products, are frequently contaminated with bacterial pathogens and implicated in foodborne illnesses. The objective of this study was to develop a unique in-situ sequential surface decontamination method for produce using sodium chlorite and acid. The ...

  16. Infections and exposures: reported incidents associated with unsuccessful decontamination of reusable surgical instruments.

    PubMed

    Southworth, P M

    2014-11-01

    Reusable surgical instruments provide a potential route for the transmission of pathogenic agents between patients in healthcare facilities. As such, the decontamination process between uses is a vital component in the prevention of healthcare-associated infections. This article reviews reported outbreaks and incidents associated with inappropriate, inadequate, or unsuccessful decontamination of surgical instruments, indicating potential pitfalls of decontamination practices worldwide. To the author's knowledge, this is the first review of surgical instrument decontamination failures. Databases of medical literature, Medline and Embase, were searched systematically. Articles detailing incidents associated with unsuccessful decontamination of surgical instruments were identified. Twenty-one articles were identified reporting incidents associated with failures in decontamination. A large proportion of incidents involved the attempted disinfection, rather than sterilization, of surgical instruments (43% of articles), counter to a number of national guidelines. Instruments used in eye surgery were most frequently reported to be associated with decontamination failures (29% of articles). Of the few articles detailing potential or confirmed pathogenic transmission, Pseudomonas aeruginosa and Mycobacterium spp. were most represented. One incident of possible variant Creutzfeldt-Jakob disease transmission was also identified. Limitations of analysing only published incidents mean that the likelihood of under-reporting (including reluctance to publish failure) must be considered. Despite these limitations, the small number of articles identified suggests a relatively low risk of cross-infection through reusable surgical instruments when cleaning/sterilization procedures are adhered to. The diverse nature of reported incidents also suggests that failures are not systemic. Copyright © 2014 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  17. Recent developments in chemical decontamination technology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wood, C.J.

    1995-03-01

    Chemical decontamination of parts of reactor coolant systems is a mature technology, used routinely in many BWR plants, but less frequently in PWRs. This paper reviews recent developments in the technology - corrosion minimization, waste processing and full system decontamination, including the fuel. Earlier work was described in an extensive review published in 1990.

  18. Aptamers as the Agent in Decontamination Assays (Apta-Decontamination Assays): From the Environment to the Potential Application In Vivo

    PubMed Central

    Bilibana, Mawethu Pascoe; Yeoh, Tzi Shien; Tang, Thean-Hock

    2017-01-01

    The binding specificity and affinity of aptamers have long been harnessed as the key elements in the development of aptamer-based assays, particularly aptasensing application. One promising avenue that is currently explored based on the specificity and affinity of aptamers is the application of aptamers in the decontamination assays. Aptamers have been successfully harnessed as the decontamination agents to remove contaminants from the environment and to decontaminate infectious elements. The reversible denaturation property inherent in aptamers enables the repeated usage of aptamers, which can immensely save the cost of decontamination. Analogous to the point-of-care diagnostics, there is no doubt that aptamers can also be deployed in the point-of-care aptamer-based decontamination assay, whereby decontamination can be performed anywhere and anytime for instantaneous decision-making. It is also prophesied that aptamers can also serve more than as a decontaminant, probably as a tool to capture and kill hazardous elements, particularly pathogenic agents. PMID:29225967

  19. Transfer of Salmonella enterica Serovar Typhimurium from Beef to Tomato through Kitchen Equipment and the Efficacy of Intermediate Decontamination Procedures.

    PubMed

    Gkana, E; Lianou, A; Nychas, G-J E

    2016-07-01

    It is well established that a high percentage of foodborne illness is caused by failure of consumers to prepare food in a hygienic manner. Indeed, a common practice in households is to use the same kitchen equipment for both raw meat and fresh produce. Such a practice may lead to cross-contamination of fruits and vegetables, which are mainly consumed without further processing, with pathogenic microorganisms originating from raw meat. The present study was performed to examine the transfer of the pathogenic bacterium Salmonella enterica serovar Typhimurium from inoculated beef fillets to tomatoes via contact with high-density polyethylene (PE), stainless steel (SS), and wooden (WD) surfaces and through cutting with SS knives. Furthermore, the following decontamination procedures were applied: (i) rinsing with tap water, (ii) scrubbing with tap water and liquid dish detergent, and (iii) using a commercial antibacterial spray. When surfaces and knives that came into contact with contaminated beef fillets were not cleaned prior to handling tomatoes, the lowest level of pathogen transfer to tomatoes was observed through PE surfaces. All of the decontamination procedures applied were more effective on knives than on surfaces, while among the surface materials tested, WD surfaces were the most difficult to decontaminate, followed by PE and SS surfaces. Mechanical cleaning with tap water and detergent was more efficient in decontaminating WD surfaces than using commercial disinfectant spray, followed by rinsing only with water. Specifically, reductions of 2.07 and 1.09 log CFU/cm(2) were achieved by washing the WD surfaces with water and detergent and spraying the surfaces with an antibacterial product, respectively. Although the pathogen's populations on SS and PE surfaces, as well as on tomatoes, after both aforementioned treatments were under the detection limit, the surfaces were all positive after enrichment, and thus, the potential risk of cross-contamination cannot be overlooked. As demonstrated by the results of this study, washing or disinfection of kitchen equipment may not be sufficient to avoid cross-contamination of ready-to-eat foods with foodborne pathogens, depending on the decontamination treatment applied and the material of the surfaces treated. Therefore, separate cutting boards and knives should be used for processing raw meat and preparing ready-to-eat foods in order to enhance food safety.

  20. Evaluation of Hydrogel Technologies for the Decontamination ...

    EPA Pesticide Factsheets

    Report This current research effort was developed to evaluate intermediate level (between bench-scale and large-scale or wide-area implementation) decontamination procedures, materials, technologies, and techniques used to remove radioactive material from different surfaces. In the event of such an incident, application of this technology would primarily be intended for decontamination of high-value buildings, important infrastructure, and landmarks.

  1. Analysis of the effectiveness of Sodium Hypochlorite decontamination of cadaveric human tissues at retrieval.

    PubMed

    Paolin, Adolfo; Trojan, Diletta; Carniato, Antonio; Tasca, Fabio; Massarin, Ervino; Tugnoli, Alessandro; Cogliati, Elisa

    2016-12-01

    Bacterial contamination of tissues retrieved from cadaveric donors is a common feature worldwide, and every tissue bank, albeit using different methods, conducts decontamination to guarantee safe tissues suitable for clinical use. The effectiveness of the methods used to eradicate pathogens differs. In order to reduce the tissue bioburden at retrieval, we have introduced a new method involving rinsing tissues in a sodium hypochlorite solution. To test its effectiveness we analyzed two comparable groups of tissues: Group A: 1881 tissues, all rinsed with isotonic saline solution after retrieval, and Group B: 1968 tissues immersed in an isotonic saline solution containing sodium hypochlorite (final concentration 0.1 %) for different lengths of time and subsequently rinsed with isotonic saline. The rinsing solution of each tissue was then sampled for microbiological cultures in both groups. The resultant overall contamination rate was 40.5 % for Group A and 6.7 % for Group B, with an 82.8 % difference in the reduction of contamination between the two groups. This was especially the case for commensal skin bacteria in musculoskeletal tissue, which accounted for over half the overall contamination. Our data highlighted that decontamination with sodium hypochlorite was helpful in reducing the bacterial bioburden in tissues retrieved from cadaveric donors.

  2. [Selective digestive decontamination. Why don't we apply the evidence in the clinical practice?].

    PubMed

    Taylor, N; van Saene, H K F; Abella, A; Silvestri, L; Vucic, M; Peric, M

    2007-04-01

    Selective digestive decontamination (SDD) is a prophylactic strategy whose objective is to reduce the incidence of infections, mainly mechanical ventilation associated pneumonia in patients who require intensive cares, preventing or eradicating the oropharyngeal and gastrointestinal carrier state of potentially pathogenic microorganisms. Fifty-four randomized clinical trials (RCTs) and 9 meta-analysis have evaluated SDD. Thirty eight RCTs show a significant reduction of the infections and 4 of mortality. All the meta-analyses show a significant reduction of the infections and 5 out of the 9 meta-analyses report a significant reduction in mortality. Thus, 5 patients from the ICU with SDD must be treated to prevent pneumonia and 12 patients from the ICU should be treated to prevent one death. The data that show benefit of the SDD on mortality have an evidence grade 1 or recommendation grade A (supported by at least two level 1 investigations). The aim of this review is to explain the pathogeny of infections in critical patients, describe selective digestive decontamination, analyze the evidence available on it efficacy and the potential adverse effects and discuss the reasons published by the experts who advise against the use of SDD, even though it is recognized as the best intervention evaluated in intensive cares to reduce morbidity and mortality of the infections.

  3. NHS connecting for health: healthcare professionals, mobile technology, and infection control.

    PubMed

    Brady, Richard R W; Chitnis, Shruti; Stewart, Ross W; Graham, Catriona; Yalamarthi, Satheesh; Morris, Keith

    2012-05-01

    Mobile phones improve the efficiency of clinical communication and are increasingly involved in all areas of healthcare delivery. Despite this, healthcare workers' mobile phones provide a known reservoir of pathogenic bacteria, with the potential to undermine infection control efforts aimed at the reducing bacterial cross-contamination in hospitals. This potential could be amplified further when employers require doctors to carry additional electronic devices for communication, without concurrently providing appropriate guidance on decontamination or use. Eighty-seven on-call doctors' mobile phones were sampled for bacterial growth prior to, and 12 h after, a cleaning intervention involving 70% isopropyl alcohol. Seventy-eight percent of doctors were aware that mobile phones could carry pathogenic bacteria, but only 8% cleaned their phones regularly. The cleaning intervention reduced the number of phones that grew bacteria by 79% (55% [48 of 87] before versus 16% [14 of 87] after cleaning). Eight percent of the phones grew Staphyloccus aureus, and 44.8% of phones grew Gram-positive cocci. All S. aureus isolates were methicillin-sensitive. Bacterial contamination was not associated with gender, specialty, or seniority of the phone user (p>0.05). Simple cleaning interventions can reduce the surface bioburden of hospital-provided doctors' mobile phones and therefore the potential for cross-contamination. This cleaning intervention is inexpensive, easily instituted, and effective. Healthcare workers should carry the minimum number of electronic devices on their person, maintain good hand hygiene, and clean their device appropriately in order to minimize the potential for cross-contamination in the work place.

  4. Supplemental treatment of air in airborne infection isolation rooms using high-throughput in-room air decontamination units.

    PubMed

    Bergeron, Vance; Chalfine, Annie; Misset, Benoît; Moules, Vincent; Laudinet, Nicolas; Carlet, Jean; Lina, Bruno

    2011-05-01

    Evidence has recently emerged indicating that in addition to large airborne droplets, fine aerosol particles can be an important mode of influenza transmission that may have been hitherto underestimated. Furthermore, recent performance studies evaluating airborne infection isolation (AII) rooms designed to house infectious patients have revealed major discrepancies between what is prescribed and what is actually measured. We conducted an experimental study to investigate the use of high-throughput in-room air decontamination units for supplemental protection against airborne contamination in areas that host infectious patients. The study included both intrinsic performance tests of the air-decontamination unit against biological aerosols of particular epidemiologic interest and field tests in a hospital AII room under different ventilation scenarios. The unit tested efficiently eradicated airborne H5N2 influenza and Mycobacterium bovis (a 4- to 5-log single-pass reduction) and, when implemented with a room extractor, reduced the peak contamination levels by a factor of 5, with decontamination rates at least 33% faster than those achieved with the extractor alone. High-throughput in-room air treatment units can provide supplemental control of airborne pathogen levels in patient isolation rooms. Copyright © 2011 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  5. Potential biodefense model applications for portable chlorine dioxide gas production.

    PubMed

    Stubblefield, Jeannie M; Newsome, Anthony L

    2015-01-01

    Development of decontamination methods and strategies to address potential infectious disease outbreaks and bioterrorism events are pertinent to this nation's biodefense strategies and general biosecurity. Chlorine dioxide (ClO2) gas has a history of use as a decontamination agent in response to an act of bioterrorism. However, the more widespread use of ClO2 gas to meet current and unforeseen decontamination needs has been hampered because the gas is too unstable for shipment and must be prepared at the application site. Newer technology allows for easy, onsite gas generation without the need for dedicated equipment, electricity, water, or personnel with advanced training. In a laboratory model system, 2 unique applications (personal protective equipment [PPE] and animal skin) were investigated in the context of potential development of decontamination protocols. Such protocols could serve to reduce human exposure to bacteria in a decontamination response effort. Chlorine dioxide gas was capable of reducing (2-7 logs of vegetative and spore-forming bacteria), and in some instances eliminating, culturable bacteria from difficult to clean areas on PPE facepieces. The gas was effective in eliminating naturally occurring bacteria on animal skin and also on skin inoculated with Bacillus spores. The culturable bacteria, including Bacillus spores, were eliminated in a time- and dose-dependent manner. Results of these studies suggested portable, easily used ClO2 gas generation systems have excellent potential for protocol development to contribute to biodefense strategies and decontamination responses to infectious disease outbreaks or other biothreat events.

  6. Understanding Mechanism of Photocatalytic Microbial Decontamination of Environmental Wastewater

    PubMed Central

    Regmi, Chhabilal; Joshi, Bhupendra; Ray, Schindra K.; Gyawali, Gobinda; Pandey, Ramesh P.

    2018-01-01

    Several photocatalytic nanoparticles are synthesized and studied for potential application for the degradation of organic and biological wastes. Although these materials degrade organic compounds by advance oxidation process, the exact mechanisms of microbial decontamination remains partially known. Understanding the real mechanisms of these materials for microbial cell death and growth inhibition helps to fabricate more efficient semiconductor photocatalyst for large-scale decontamination of environmental wastewater or industries and hospitals/biomedical labs generating highly pathogenic bacteria and toxic molecules containing liquid waste by designing a reactor. Recent studies on microbial decontamination by photocatalytic nanoparticles and their possible mechanisms of action is highlighted with examples in this mini review. PMID:29541632

  7. Efficacy of antimicrobial compounds on surface decontamination of seven shiga toxin-producing Escherichia coli (STEC) and Salmonella inoculated onto fresh beef

    USDA-ARS?s Scientific Manuscript database

    Several antimicrobial compounds have been implemented in commercial meat processing plants for decontamination of pathogens on beef carcasses, but there are many commercially available, novel antimicrobial compounds that may be more effective and suitable to be implemented in beef processing pathoge...

  8. Efficacy of titanium dioxide nanoparticle spray to disinfect mobile phones used by endodontist: A bacteriological study.

    PubMed

    Palaniswamy, Udayakumar; Habeeb, Aisha; Mohsin, Mohammed

    2018-01-01

    The objectives of this study were to determine the bacterial contamination of the mobile phones that were used by the endodontist in comparison with the general dentist and also to determine the usefulness of titanium dioxide nanospray (TiO 2 NS) in mobile phone decontamination. Samples from the 60 mobile phones were taken using moist sterile swabs before, 10 min, and 1 week after the use of TiO 2 NS. Before collection of the swabs, the participants' informed consent was obtained. Samples obtained were cultured on blood agar to identify bacterial isolates. All 60 mobile phone cultures were found to be culture positive. There was a significant reduction in the mean number of colony-forming units after decontamination with TiO 2 NS ( P < 0.001). The results from this study showed that the mobile phones may act as an important source of nosocomial pathogens and TiO 2 NS would be an effective decontaminant. Therefore, it is important for dental professionals to practice routine mobile phone disinfection protocol to reduce the chances of occurrence of nosocomial infections.

  9. Advanced Decontamination Technologies: Irradiation

    NASA Astrophysics Data System (ADS)

    Lee, Eun Joo; Ahn, Dong U.

    Bacterial food-borne illnesses account for an estimated 76 million cases, 325,000 hospitalizations, and 5,000 deaths each year in the United States (CDCP, 2005), and 5,300 food-borne outbreaks in Europe resulted in 5,330 hospitalizations and 24 deaths in 2005 (Aymerich, Picouet, & Monfort, 2008). Major food-borne pathogens of concern include Escherichia coli O157:H7, Campylobacter jejuni/coli, Salmonella spp., Listeria monocytogenes, Clostridium botulinum/perfringens, Staphylococcus aureus, Aeromonas hydrophylia, and Bacillus cereu, and spoilage microorganisms include Pseudomonas, Acinetobacter/Moraxella, Aeromonas, Alteromonas putrefaciens, Lactobacillus, and Brochothrix thermosphecta (Mead et al., 1999).

  10. Efficacy of antimicrobials for the disinfection of pathogen contaminated green bell pepper and of consumer cleaning methods for the decontamination of knives.

    PubMed

    Perez, Keila L; Lucia, Lisa M; Cisneros-Zevallos, Luis; Castillo, Alejandro; Taylor, T Matthew

    2012-05-01

    While there is strong focus on eliminating pathogens from produce at a commercial level, consumers can employ simple methods to achieve additional pathogen reductions in the domestic kitchen. To determine the ability of antimicrobials to decontaminate peppers, samples of green bell pepper were inoculated with Salmonella enterica and Escherichia coli O157:H7 and then immersed in 3% (v/v) hydrogen peroxide (H₂O₂), 2.5% (v/v) acetic acid (AA), 70% (v/v) ethyl alcohol (EtOH), or sterile distilled water (SDW). The potential for transfer of pathogens from contaminated peppers to other non-contaminated produce items, and the effect of knife disinfection in preventing this cross contamination, were also tested. Knife disinfection procedures were evaluated by chopping inoculated peppers into 1 cm² pieces with kitchen knives. Experimental knives were then treated by either no treatment (control), wiping with a dry sterile cotton towel, rinsing under running warm water for 5 or 10s, or applying a 1% (v/v) lauryl sulfate-based detergent solution followed by rinsing with warm running water for 10s. Following disinfection treatment, knives were used to slice cucumbers. Exposure to H₂O₂ for 5 min and EtOH for 1 min resulted in reductions of 1.3±0.3 log₁₀ CFU/cm² for both pathogens. A 5 min exposure to AA resulted in a reduction of S. enterica of 1.0±0.7 log₁₀ CFU/cm² and E. coli of 0.7±0.8 log₁₀ CFU/cm². No differences (p ≥ 0.05) were found between numbers of pathogens on knives and numbers of pathogens transferred to cucumber slices, suggesting that organisms remaining on knife surfaces were transferred to cucumbers during slicing. Findings suggest that EtOH and H₂O₂ may be effective antimicrobials for in-home decontamination of peppers, and that use of detergent and warm water is effective for decontamination of implements used during meal preparation. Published by Elsevier B.V.

  11. Inactivation of foodborne pathogenic and spoilage micro-organisms using ultraviolet-A light in combination with ferulic acid.

    PubMed

    Shirai, A; Watanabe, T; Matsuki, H

    2017-02-01

    The low energy of UV-A (315-400 nm) is insufficient for disinfection. To improve UV-A disinfection technology, we evaluated the effect of ferulic acid (FA) addition on disinfection by UV-A light-emitting diode (LED) (350-385 nm) against various food spoilers and pathogens (seven bacteria and four fungi species). Photoantimicrobial assays were performed at FA concentrations below the MIC. The MIC of the isomerized FA, consisting of 93% cis-form and 7% trans-form, was very similar to that of the commercially available FA (trans-form). Irradiation with UV-A (1·0 J cm -2 ) in the presence of 100 mg l -1 FA resulted in enhanced reducing of all of the tested bacterial strains. A combination of UV-A (10 J cm -2 ) and 1000 mg l -1 FA resulted in enhanced reducing of Saccharomyces cerevisiae and one of the tested filamentous fungi. These results demonstrated that the combination of a short-term application of UV-A and FA at a low concentration yielded synergistic enhancement of antimicrobial activity, especially against bacteria. Microbial contamination is one of the most serious problems for foods, fruit and sugar thick juices. UV light is suitable for the nonthermal decontamination of food products by inactivating the contaminating micro-organisms. However, UV-A exposure is insufficient for disinfection. This study demonstrates that the combination of UV-A LED light (350-385 nm), which is not hazardous to human eyes and skin, and ferulic acid (FA), a known phytochemical and food additive, provides synergistic antimicrobial activity against foodborne pathogenic and spoilage micro-organisms. Therefore, FA addition to UV-A light treatment may be useful for improvement of UV-A disinfection technology to prevent food deterioration. © 2016 The Society for Applied Microbiology.

  12. [Decontamination of chemical and biological warfare agents].

    PubMed

    Seto, Yasuo

    2009-01-01

    Chemical and biological warfare agents (CBWA's) are diverse in nature; volatile acute low-molecular-weight toxic compounds, chemical warfare agents (CWA's, gaseous choking and blood agents, volatile nerve gases and blister agents, nonvolatile vomit agents and lacrymators), biological toxins (nonvolatile low-molecular-weight toxins, proteinous toxins) and microbes (bacteria, viruses, rickettsiae). In the consequence management against chemical and biological terrorism, speedy decontamination of victims, facilities and equipment is required for the minimization of the damage. In the present situation, washing victims and contaminated materials with large volumes of water is the basic way, and additionally hypochlorite salt solution is used for decomposition of CWA's. However, it still remains unsolved how to dispose large volumes of waste water, and the decontamination reagents have serious limitation of high toxicity, despoiling nature against the environments, long finishing time and non-durability in effective decontamination. Namely, the existing decontamination system is not effective, nonspecifically affecting the surrounding non-target materials. Therefore, it is the urgent matter to build up the usable decontamination system surpassing the present technologies. The symposiast presents the on-going joint project of research and development of the novel decontamination system against CBWA's, in the purpose of realizing nontoxic, fast, specific, effective and economical terrorism on-site decontamination. The projects consists of (1) establishment of the decontamination evaluation methods and verification of the existing technologies and adaptation of bacterial organophosphorus hydrolase, (2) development of adsorptive elimination technologies using molecular recognition tools, and (4) development of deactivation technologies using photocatalysis.

  13. Evaluation of an automated room decontamination device using aerosolized peracetic acid.

    PubMed

    Mana, Thriveen S C; Sitzlar, Brett; Cadnum, Jennifer L; Jencson, Annette L; Koganti, Sreelatha; Donskey, Curtis J

    2017-03-01

    Because manual cleaning is often suboptimal, there is increasing interest in use of automated devices for room decontamination. We demonstrated that an ultrasonic room fogging system that generates submicron droplets of peracetic acid and hydrogen peroxide eliminated Clostridium difficile spores and vegetative pathogens from exposed carriers in hospital rooms and adjacent bathrooms. Published by Elsevier Inc.

  14. Microwave drying remediation of petroleum-contaminated drill cuttings.

    PubMed

    Júnior, Irineu Petri; Martins, André Leibsohn; Ataíde, Carlos H; Duarte, Cláudio R

    2017-07-01

    The oil reservoir drilling phase generates contaminated cuttings with oil formation itself. These cuttings must be subjected to a decontamination process before being disposed of in the environment. Several technologies are cited in literature for the remediation of soil contaminated with oil or diesel, but none have been reported to remedy drill cuttings contaminated with oil from reservoir. The reservoir drill cuttings are a problem because its discharge is not allowed. The drying technology using microwave has shown promise in the decontamination of cuttings with non-aqueous base drilling fluid, conciliating good robustness and high removal efficiency. Considering the aspects mentioned previously, the application of heating and drying technology using microwave in the remediation of oil contaminated cuttings from well drill was studied. The influence of temperature, specific energy and initial content of water in the drying operation of the reservoir cuttings and of the drilling cuttings artificially contaminated with oil were analyzed. The results showed an influence of temperature in the drying of the cuttings, being necessary to reach the boiling temperature of heavier hydrocarbons to reach an efficient removal in the operation. The specific energy has a strong influence, reaching a total decontamination using 2.67 kWh/kg. The initial water content was effective in removing oil, reducing the residual level of oil with the increase of initial content of water. It also modifies the temperature profiles of the kinetic-warming of the contaminated cuttings. Both the technology and the equipment used proved effective for obtaining total decontamination of oil from the cuttings. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Inactivation of pathogenic bacteria in food matrices: high pressure processing, photodynamic inactivation and pressure-assisted photodynamic inactivation

    NASA Astrophysics Data System (ADS)

    Cunha, A.; Couceiro, J.; Bonifácio, D.; Martins, C.; Almeida, A.; Neves, M. G. P. M. S.; Faustino, M. A. F.; Saraiva, J. A.

    2017-09-01

    Traditional food processing methods frequently depend on the application of high temperature. However, heat may cause undesirable changes in food properties and often has a negative impact on nutritional value and organoleptic characteristics. Therefore, reducing the microbial load without compromising the desirable properties of food products is still a technological challenge. High-pressure processing (HPP) can be classified as a cold pasteurization technique, since it is a non-thermal food preservation method that uses hydrostatic pressure to inactivate spoilage microorganisms. At the same time, it increases shelf life and retains the original features of food. Photodynamic inactivation (PDI) is also regarded as promising approach for the decontamination of food matrices. In this case, the inactivation of bacterial cells is achieved by the cytotoxic effects of reactive oxygens species (ROS) produced from the combined interaction of a photosensitizer molecule, light and oxygen. This short review examines some recent developments on the application of HPP and PDI with food-grade photosensitizers for the inactivation of listeriae, taken as a food pathogen model. The results of a proof-of-concept trial of the use of high-pressure as a coadjutant to increase the efficiency of photodynamic inactivation of bacterial endospores is also addressed.

  16. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT: BIOQUELL, INC. CLARIS C HYDROGEN PEROXIDE GAS GENERATOR

    EPA Science Inventory

    The Environmental Technology Verification report discusses the technology and performance of the Clarus C Hydrogen Peroxide Gas Generator, a biological decontamination device manufactured by BIOQUELL, Inc. The unit was tested by evaluating its ability to decontaminate seven types...

  17. VERIFICATION OF THE PERFORMANCE OF DECONTAMINATION TECHNOLOGIES IN EPA'S SAFE BUILDINGS PROGRAM

    EPA Science Inventory

    The paper describes initial progress in identifying and testing technologies applicable for decontaminating workplaces and other buildings that may be subject to chemical or biological attack. The EPA is using the process established in its Environmental Technology Verification (...

  18. Atmospheric Pressure Plasma Jet for Chem/Bio Warfare Decontamination

    NASA Astrophysics Data System (ADS)

    Herrmann, Hans W.; Henins, Ivars; Park, Jaeyoung; Selwyn, Gary S.

    1999-11-01

    Atmospheric Pressure Plasma Jet (APPJ) technology may provide a much needed method of CBW decontamination which, unlike traditional decon methods, is dry and nondestructive to sensitive equipment and materials. The APPJ discharge uses a high-flow feedgas consisting primarily of an inert carrier gas, such as He, and a small amount of a reactive additive, such as O2, which flows between capacitively-coupled electrodes powered at 13.56 MHz. The plasma generates highly reactive metastable and atomic species of oxygen which are then directed onto a contaminated surface. The reactive effluent of the APPJ has been shown to effectively neutralize VX nerve agent as well as simulants for anthrax and mustard blister agent. Research efforts are now being directed towards reducing He consumption and increasing the allowable stand-off distance. Recent results demonstrate that by replacing the O2 reactive additive with CO2, ozone formation is greatly reduced. This has the result of extending the lifetime of atomic oxygen by an order of magnitude or more. A recirculating APP Decon Chamber which combines heat, vacuum, forced convection and reactivity is currently being developed for enhanced decontamination of sensitive equipment. Several techniques are also being evaluated for use in an APP Decon Jet for decontamination of items which cannot be placed inside a chamber.

  19. Bacteriological findings in patients with bone marrow transplantation (Karl Marx University Leipzig, 1985-1987).

    PubMed

    Wonitzki, C; Hoffmann, F A

    1989-01-01

    The results of the bacteriological surveillance cultures for 26 patients with bone marrow transplantation (Karl Marx University Leipzig, G.D.R., 1985-1987) are presented. 5.9% of all surveillance cultures contained facultatively pathogenic germs (with Pseudomonas aeruginosa as the most frequent representative, which was the reason of a sepsis in two patients). Coagulasenegative Staphylococci and other germs with an obscure pathogenicity were isolated upon a large scale, especially from the mucous membrane regions. There are hints, that above all special strains of coagulasenegative Staphylococci "colonize" the patient's body (also for longer periods) and turn into the blood too. During the total decontamination intestinal anaerobic flora is absent. After closing of total decontamination Clostridium perfringens is the first detectable anaerobic species. During the selective decontamination systemic applications of antibiotics are able to obliterate anaerobic findings for certain periods. Recommendations for an effective arrangement of the surveillance cultures of bone marrow transplantation patients are given.

  20. Nuclear decontamination technology evaluation to address contamination of a municipal water system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McFee, J.; Langsted, J.; Young, M.

    The US Environmental Protection Agency (EPA) and US Department of Homeland Security (DHS) are considering the impact and recovery from contamination of municipal water systems, including intentional contamination of those systems. Industrial chemicals, biological agents, drugs, pesticides, chemical warfare agents, and radionuclides all could be introduced into a municipal water system to create detrimental health effects and disrupt a community. Although unintentional, the 1993 cryptosporidium contamination of the Milwaukee WS water system resulted in 100 fatalities and disrupted the city for weeks. Shaw Environmental and Infrastructure Inc, (Shaw), as a subcontractor on a DHS contract with Michael Baker Jr., Inc.,more » was responsible for evaluation of the impact and recovery from radionuclide contamination in a municipal water system distribution system. Shaw was tasked to develop a matrix of nuclear industry decontamination technologies and evaluate applicability to municipal water systems. Shaw expanded the evaluation to include decontamination methods commonly used in the drinking water supply. The matrix compared all technologies for implementability, effectiveness, and cost. To address the very broad range of contaminants and contamination scenarios, Shaw bounded the problem by identification of specific contaminant release scenario(s) for specific water system architecture(s). A decontamination technology matrix was developed containing fifty-nine decontamination technologies potentially applicable to the water distribution system piping, pumps, tanks, associated equipment, and/or contaminated water. Qualitatively, the majority of the nuclear industry decontamination technologies were eliminated from consideration due to implementability concerns. However, inclusion of the municipal water system technologies supported recommendations that combined the most effective approaches in both industries. (authors)« less

  1. Microbiology of Fresh Produce: Route of Contamination, Detection Methods, and Remedy.

    PubMed

    Rajwar, Asmita; Srivastava, Pragati; Sahgal, Manvika

    2016-10-25

    Fresh fruits and vegetables are an important part of a healthful diet. They provide vitamins, minerals and fiber to help keep our body healthy. Occasionally, fresh fruits and vegetables can become contaminated with harmful bacteria or viruses, which are also known as pathogens. The major family of pathogen associated with food are members of Enterobacteriaceae which commonly form a part of microbiological criteria and their presence is traditionally related to hygiene and safety of foods. Organic fertilizers, irrigation water quality and soil are major source of contamination. For removal of pathogens, various decontamination procedures are also followed to reduce microbial load on the fruits. These are chemical preservatives and irradiation. Microbiological study of fresh produce can be done by various phenotypic, biochemical and molecular techniques so that pathogen can properly be identified. The World Health Organization (WHO) developed global risk communication message and training materials to assist countries in strengthening their food educating programs. There is a need for improved surveillance systems on food-borne pathogens, on food products and on outbreaks so that comparable data are available from a wider range of countries.

  2. Decontamination Efficacy Testing of COTS SteriFx Prodcuts for Mass Personnel and Casualty Decontamination

    DTIC Science & Technology

    2011-09-01

    low‐cost, lightweight, single‐use individual product for field self ‐decontamination. Surface (skin) decontamination of Bacillus subtilis spores has...field spray decontamination unit was previously demonstrated in 2003 at Guantanamo Bay, Cuba (Dankert, 2003), and for wound healing with repeated...Technology on plastics, rubber and plastic tubing, and clothing. Demonstrate ability of CleanseFx to function as skin cleanser in military setting

  3. Effects of Vaporized Decontamination Systems on Selected Building Interior Materials: Vaporized Hydrogen Peroxide

    DTIC Science & Technology

    2009-01-01

    surfaces in buildings following a terrorist attack using CB agents. Vaporized hydrogen peroxide ( VHP ) and Cl02 are decontamination technologies that...decontaminant. The focus of this technical report is the evaluation of the building interior materials and the Steris VHP technology. 15. SUBJECT...TERMS Material Compatibility VHP vaporized hydrogen peroxide 16. SECURITY CLASSIFICATION OF: a. REPORT U b. ABSTRACT U c. THIS PAGE U 17

  4. NATIONAL RESPONSE TEAM TECHNICAL ASSISTANCE ...

    EPA Pesticide Factsheets

    This document provides technical information on a wide range of activities to aid in response to intentional release of anthrax in urban environments. It includes initial actions when a potential release is discovered, health and safety issues for responders, sampling and analysis methods, decontamination technologies, decontamination waste disposal, and communication with public. This document provides technical information on a wide range of activities to aid in response to intentional release of anthrax in urban environments. It includes initial actions when a potential release is discovered, health and safety issues for responders, sampling and analysis methods, decontamination technologies, decontamination waste disposal, and communication with public.

  5. Effects of CBRN decontaminants in common use by first responders on the recovery of latent fingerprints--assessment of the loss of ridge detail on glass.

    PubMed

    Zuidberg, Matthijs C; van Woerkom, Tiest; de Bruin, Karla G; Stoel, Reinoud D; de Puit, Marcel

    2014-01-01

    Following a CBRN incident, first responders use decontamination procedures to reduce the risk of exposure. The effect of decontamination on forensic trace material has, however, not been fully examined. This study sought to evaluate the effect of five different physical or chemical decontamination materials on the recovery of latent fingerprints. Fingerprints were deposited on glass slides, decontaminated, and assessed on the presence of ridge detail. The results demonstrate that decontamination affects the quality of latent fingerprints substantially. On at least 61% of the fingerprints, a reduced amount of ridge detail was observed upon decontamination. Furthermore, development with cyanoacrylate appeared not to succeed anymore. Instead, the ability of vacuum metal deposition to successfully develop decontaminated fingerprints is demonstrated. The results from this study may contribute to an increased forensic awareness regarding decontamination and emphasize the necessity for further research into new item decontamination procedures or new forensic initiatives prior to decontamination. © 2013 American Academy of Forensic Sciences.

  6. Cold plasma rapid decontamination of food contact surfaces contaminated with Salmonella biofilms

    USDA-ARS?s Scientific Manuscript database

    Cross-contamination of fresh produce and other foods from persistent pathogen reservoirs is a known risk factor in processing environments. Industry requires a rapid, waterless, zero-contact, chemical-free method for removing pathogens from food-contact surfaces. Cold plasma was tested for its abili...

  7. Ultraviolet light (UV) and UV-ozone interventions reduce shiga toxin-producing Escherichia coli (STEC) on contaminated fresh beef

    USDA-ARS?s Scientific Manuscript database

    Although numerous chemical interventions have been implemented and validated to decontaminate meat and meat products during the harvesting process, more novel technologies are under development. UV light ionizing irradiation has been used extensively in pharmaceutical and medical device companies to...

  8. Reduced weight decontamination formulation utilizing a solid peracid compound for neutralization of chemical and biological warfare agents

    DOEpatents

    Tucker, Mark D [Albuquerque, NM

    2011-09-20

    A reduced weight decontamination formulation that utilizes a solid peracid compound (sodium borate peracetate) and a cationic surfactant (dodecyltrimethylammonium chloride) that can be packaged with all water removed. This reduces the packaged weight of the decontamination formulation by .about.80% (as compared to the "all-liquid" DF-200 formulation) and significantly lowers the logistics burden on the warfighter. Water (freshwater or saltwater) is added to the new decontamination formulation at the time of use from a local source.

  9. Porcine semen as a vector for transmission of viral pathogens.

    PubMed

    Maes, Dominiek; Van Soom, Ann; Appeltant, Ruth; Arsenakis, Ioannis; Nauwynck, Hans

    2016-01-01

    Different viruses have been detected in porcine semen. Some of them are on the list of the World Organization for Animal Health (OIE), and consequently, these pathogens are of socioeconomic and/or public health importance and are of major importance in the international trade of animals and animal products. Artificial insemination (AI) is one of the most commonly used assisted reproductive technologies in pig production worldwide. This extensive use has enabled pig producers to benefit from superior genetics at a lower cost compared to natural breeding. However, the broad distribution of processed semen doses for field AI has increased the risk of widespread transmission of swine viral pathogens. Contamination of semen can be due to infections of the boar or can occur during semen collection, processing, and storage. It can result in reduced semen quality, embryonic mortality, endometritis, and systemic infection and/or disease in the recipient female. The presence of viral pathogens in semen can be assessed by demonstration of viable virus, nucleic acid of virus, or indirectly by measuring serum antibodies in the boar. The best way to prevent disease transmission via the semen is to assure that the boars in AI centers are free from the disease, to enforce very strict biosecurity protocols, and to perform routine health monitoring of boars. Prevention of viral semen contamination should be the primary focus because it is easier to prevent contamination than to eliminate viruses once present in semen. Nevertheless, research and development of novel semen processing treatments such as single-layer centrifugation is ongoing and may allow in the future to decontaminate semen. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. The simulation of decontamination works in premises of the research reactor in NRC 'Kurchatov institute'

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Danilovich, Alexey; Ivanov, Oleg; Potapov, Victor

    2013-07-01

    Application of remote sensing methods using a spectrometric collimated system allows obtaining information about features of a formation of radiation fields in contaminated premises. This information helps in a preparation of a phased plan for dismantling of contaminated equipment. When the survey of technological premises of the research reactor at the Russian Research Centre 'Kurchatov institute' was conducted the remote controlled collimated spectrometric system was used. With its help the scanning of surveyed premises were carried out. As a result of this work, the distribution pattern of radionuclides activity was restored. The simulation of decontamination works was carried out andmore » maps of the distribution of activity and dose rate for surveyed premises were plotted and superimposed on its photo for situations before and after decontamination. The use of obtained results will allow significantly reduce radiation dose for staff at work on dismantling. (authors)« less

  11. ETV REPORT: CERTEK, INC. 1414RH FORMALDEHYDE GENERATOR/NEUTRALIZER

    EPA Science Inventory

    The Environmental Technology Verification report discusses the technology and performance of the 1414RH Formaldehyde Generator/Neuralizer, a biological decontamination device manufactured by CERTEK, Inc. The unit was tested by evaluating its ability to decontaminate seven types ...

  12. COMPILATION OF AVAILABLE DATA ON BUILDING DECONTAMINATION ALTERNATIVES

    EPA Science Inventory

    The report presents an analysis of selected technologies that have been tested for their potential effectiveness in decontaminating a building that has been attacked using biological or chemical warfare agents, or using toxic industrial compounds. The technologies selected to be ...

  13. Evaluation of an Innovative Use of Removable Thin Film Coating Technology for the Abatement of Hazardous Contaminants

    PubMed Central

    Lumia, Margaret E.; Gentile, Charles; Gochfeld, Michael; Efthimion, Philip; Robson, Mark

    2015-01-01

    This study evaluates a new decontamination technique for the mitigation and abatement of hazardous particulates. The traditional decontamination methods used to clean facilities and equipment are time-consuming, prolonging workers' exposure time, may generate airborne hazards, and can be expensive. The use of removable thin film coating as a decontamination technique for surface contamination proved to be a more efficient method of decontamination. This method was tested at three different sites on different hazardous metals. One application of the coating reduced the levels of these metals 90% and had an average reduction of one magnitude. The paired t-tests that were performed for each metal demonstrated that there was a statistically significant reduction of the metal after the use of the coating: lead (p = 0.03), beryllium (p = 0.05), aluminum (p = 0.006), iron (p = 0.0001), and copper (p = 0.004). The Kendall tau-b correlation coefficient demonstrates that there was a positive correlation between the initial levels of contamination and the removal efficiency for all the samples taken from different locations on the floor for each of the three sites. This new decontamination technique worked efficiently, requiring only one application, which decreased exposure time and did not generate any airborne dust. PMID:19437305

  14. Effect of selective decontamination on antimicrobial resistance in intensive care units: a systematic review and meta-analysis.

    PubMed

    Daneman, Nick; Sarwar, Syed; Fowler, Robert A; Cuthbertson, Brian H

    2013-04-01

    Many meta-analyses have shown reductions in infection rates and mortality associated with the use of selective digestive decontamination (SDD) or selective oropharyngeal decontamination (SOD) in intensive care units (ICUs). These interventions have not been widely implemented because of concerns that their use could lead to the development of antimicrobial resistance in pathogens. We aimed to assess the effect of SDD and SOD on antimicrobial resistance rates in patients in ICUs. We did a systematic review of the effect of SDD and SOD on the rates of colonisation or infection with antimicrobial-resistant pathogens in patients who were critically ill. We searched for studies using Medline, Embase, and Cochrane databases, with no limits by language, date of publication, study design, or study quality. We included all studies of selective decontamination that involved prophylactic application of topical non-absorbable antimicrobials to the stomach or oropharynx of patients in ICUs, with or without additional systemic antimicrobials. We excluded studies of interventions that used only antiseptic or biocide agents such as chlorhexidine, unless antimicrobials were also included in the regimen. We used the Mantel-Haenszel model with random effects to calculate pooled odds ratios. We analysed 64 unique studies of SDD and SOD in ICUs, of which 47 were randomised controlled trials and 35 included data for the detection of antimicrobial resistance. When comparing data for patients in intervention groups (those who received SDD or SOD) versus data for those in control groups (who received no intervention), we identified no difference in the prevalence of colonisation or infection with Gram-positive antimicrobial-resistant pathogens of interest, including meticillin-resistant Staphylococcus aureus (odds ratio 1·46, 95% CI 0·90-2·37) and vancomycin-resistant enterococci (0·63, 0·39-1·02). Among Gram-negative bacilli, we detected no difference in aminoglycoside-resistance (0·73, 0·51-1·05) or fluoroquinolone-resistance (0·52, 0·16-1·68), but we did detect a reduction in polymyxin-resistant Gram-negative bacilli (0·58, 0·46-0·72) and third-generation cephalosporin-resistant Gram-negative bacilli (0·33, 0·20-0·52) in recipients of selective decontamination compared with those who received no intervention. We detected no relation between the use of SDD or SOD and the development of antimicrobial-resistance in pathogens in patients in the ICU, suggesting that the perceived risk of long-term harm related to selective decontamination cannot be justified by available data. However, our study indicates that the effect of decontamination on ICU-level antimicrobial resistance rates is understudied. We recommend that future research includes a non-crossover, cluster randomised controlled trial to assess long-term ICU-level changes in resistance rates. None. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Improving Protection against Viral Aerosols Through Development of Novel Decontamination Methods and Characterization of Viral Aerosol

    DTIC Science & Technology

    2012-04-01

    attack), the spread of waterborne pathogens (e.g. typhoid fever ) and airborne pathogens (e.g. avian flu, Severe Acute Respiratory Syndromes, and...hemorrhagic fever with fatality in humans ranging from 50-89% (Biosafety level 4) (Brion and Silverstein, 1999). If one aggregate of ebola viruses

  16. Cold plasma rapid decontamination of food contact surfaces contaminated with Salmonella and Escherichia coli 0157:H7

    USDA-ARS?s Scientific Manuscript database

    Cross-contamination of fresh produce from persistent pathogen reservoirs is a known risk factor in processing environments. Industry requires a waterless, zero-contact, chemical-free method for removing pathogens from food-contact surfaces. Cold plasma was tested for its ability to remove biofilms f...

  17. Developments in Decontamination Technologies of Military Personnel and Equipment

    NASA Astrophysics Data System (ADS)

    Sata, Utkarsh R.; Ramkumar, Seshadri S.

    Individual protection is important for warfighters, first responders and civilians to meet the current threat of toxic chemicals and chemical warfare (CW) agents. Within the realm of individual protection, decontamination of warfare agents is not only required on the battlefield but also in laboratory, pilot plants, production and agent destruction sites. It is of high importance to evaluate various decontaminants and decontamination techniques for implementing the best practices in varying scenarios such as decontamination of personnel, sites and sensitive equipment.

  18. Y-12 Plant decontamination and decommissioning technology logic diagram for Building 9201-4. Volume 2: Technology logic diagram

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1994-09-01

    The Y-12 Plant Decontamination and Decommissioning Technology Logic Diagram for Building 9201-4 (TLD) was developed to provide a decision-support tool that relates decontamination and decommissioning (D and D) problems at Bldg. 9201-4 to potential technologies that can remediate these problems. This TLD identifies the research, development, demonstration, testing, and evaluation needed for sufficient development of these technologies to allow for technology transfer and application to D and D and waste management (WM) activities. It is essential that follow-on engineering studies be conducted to build on the output of this project. These studies will begin by selecting the most promising technologiesmore » identified in the TLD and by finding an optimum mix of technologies that will provide a socially acceptable balance between cost and risk. The TLD consists of three fundamentally separate volumes: Vol. 1 (Technology Evaluation), Vol. 2 (Technology Logic Diagram), and Vol. 3 (Technology Evaluation Data Sheets). Volume 2 contains the logic linkages among environmental management goals, environmental problems, and the various technologies that have the potential to solve these problems. Volume 2 has been divided into five sections: Characterization, Decontamination, Dismantlement, Robotics/Automation, and Waste Management. Each section contains logical breakdowns of the Y-12 D and D problems by subject area and identifies technologies that can be reasonably applied to each D and D challenge.« less

  19. Controlling Microbial Safety Challenges of Meat Using High Voltage Atmospheric Cold Plasma

    PubMed Central

    Han, Lu; Ziuzina, Dana; Heslin, Caitlin; Boehm, Daniela; Patange, Apurva; Sango, David M.; Valdramidis, Vasilis P.; Cullen, Patrick J.; Bourke, Paula

    2016-01-01

    Atmospheric cold plasma (ACP) is a non-thermal technology, effective against a wide range of pathogenic microorganisms. Inactivation efficacy results from plasma generated reactive species. These may interact with any organic components in a test matrix including the target microorganism, thus food components may exert a protective effect against the antimicrobial mode of action. The effect of an in-package high voltage ACP process applied in conjunction with common meat processing MAP gas compositions as well as bacteria type and meat model media composition have been investigated to determine the applicability of this technology for decontamination of safety challenges associated with meat products. E. coli, L. monocytogenes, and S. aureus in PBS were undetectable after 60 s of treatment at 80 kVRMS in air, while ACP treatment of the contaminated meat model required post-treatment refrigeration to retain antimicrobial effect. The nutritive components in the meat model exerted a protective effect during treatment, where 300 s ACP exposure yielded a maximum reduction of 1.5 log using a high oxygen atmosphere, whilst using air and high nitrogen atmospheres yielded lower antimicrobial efficacy. Furthermore, an ROS assay was performed to understand the protective effects observed using the meat model. This revealed that nutritive components inhibited penetration of ROS into bacterial cells. This knowledge can assist the optimization of meat decontamination using ACP technology where interactions with all components of the food matrix require evaluation. PMID:27446018

  20. Decontamination formulations for disinfection and sterilization

    DOEpatents

    Tucker, Mark D.; Engler, Daniel E.

    2007-09-18

    Aqueous decontamination formulations that neutralize biological pathogens for disinfection and sterilization applications. Examples of suitable applications include disinfection of food processing equipment, disinfection of areas containing livestock, mold remediation, sterilization of medical instruments and direct disinfection of food surfaces, such as beef carcasses. The formulations include at least one reactive compound, bleaching activator, inorganic base, and water. The formulations can be packaged as a two-part kit system, and can have a pH value in the range of 7-8.

  1. Cost and Effectiveness of Decontamination Strategies in Radiation Contaminated Areas in Fukushima in Regard to External Radiation Dose

    PubMed Central

    Yasutaka, Tetsuo; Naito, Wataru; Nakanishi, Junko

    2013-01-01

    The objective of the present study is to evaluate the cost and effectiveness of decontamination strategies in the special decontamination areas in Fukushima in regard to external radiation dose. A geographical information system (GIS) was used to relate the predicted external dose in the affected areas to the number of potential inhabitants and the land use in the areas. A comprehensive review of the costs of various decontamination methods was conducted as part of the analysis. The results indicate that aerial decontamination in the special decontamination areas in Fukushima would be effective for reducing the air dose rate to the target level in a short period of time in some but not all of the areas. In a standard scenario, analysis of cost and effectiveness suggests that decontamination costs for agricultural areas account for approximately 80% of the total decontamination cost, of which approximately 60% is associated with storage. In addition, the costs of decontamination per person per unit area are estimated to vary greatly. Appropriate selection of decontamination methods may significantly decrease decontamination costs, allowing more meaningful decontamination in terms of the limited budget. Our analysis can help in examining the prioritization of decontamination areas from the viewpoints of cost and effectiveness in reducing the external dose. Decontamination strategies should be determined according to air dose rates and future land-use plans. PMID:24069398

  2. Cost and effectiveness of decontamination strategies in radiation contaminated areas in Fukushima in regard to external radiation dose.

    PubMed

    Yasutaka, Tetsuo; Naito, Wataru; Nakanishi, Junko

    2013-01-01

    The objective of the present study is to evaluate the cost and effectiveness of decontamination strategies in the special decontamination areas in Fukushima in regard to external radiation dose. A geographical information system (GIS) was used to relate the predicted external dose in the affected areas to the number of potential inhabitants and the land use in the areas. A comprehensive review of the costs of various decontamination methods was conducted as part of the analysis. The results indicate that aerial decontamination in the special decontamination areas in Fukushima would be effective for reducing the air dose rate to the target level in a short period of time in some but not all of the areas. In a standard scenario, analysis of cost and effectiveness suggests that decontamination costs for agricultural areas account for approximately 80% of the total decontamination cost, of which approximately 60% is associated with storage. In addition, the costs of decontamination per person per unit area are estimated to vary greatly. Appropriate selection of decontamination methods may significantly decrease decontamination costs, allowing more meaningful decontamination in terms of the limited budget. Our analysis can help in examining the prioritization of decontamination areas from the viewpoints of cost and effectiveness in reducing the external dose. Decontamination strategies should be determined according to air dose rates and future land-use plans.

  3. Decontamination of a drinking water pipeline system contaminated with adenovirus and Escherichia coli utilizing peracetic acid and chlorine.

    PubMed

    Kauppinen, Ari; Ikonen, Jenni; Pursiainen, Anna; Pitkänen, Tarja; Miettinen, Ilkka T

    2012-09-01

    A contaminated drinking water distribution network can be responsible for major outbreaks of infections. In this study, two chemical decontaminants, peracetic acid (PAA) and chlorine, were used to test how a laboratory-scale pipeline system can be cleaned after simultaneous contamination with human adenovirus 40 (AdV40) and Escherichia coli. In addition, the effect of the decontaminants on biofilms was followed as heterotrophic plate counts (HPC) and total cell counts (TCC). Real-time quantitative polymerase chain reaction (qPCR) was used to determine AdV40 and plate counting was used to enumerate E. coli. PAA and chlorine proved to be effective decontaminants since they decreased the levels of AdV40 and E. coli to below method detection limits in both water and biofilms. However, without decontamination, AdV40 remained present in the pipelines for up to 4 days. In contrast, the concentration of cultivable E. coli decreased rapidly in the control pipelines, implying that E. coli may be an inadequate indicator for the presence of viral pathogens. Biofilms responded to the decontaminants by decreased HPCs while TCC remained stable. This indicates that the mechanism of pipeline decontamination by chlorine and PAA is inactivation rather than physical removal of microbes.

  4. The effect of ionizing radiation on microbiological decontamination of medical herbs and biologically active compounds

    NASA Astrophysics Data System (ADS)

    Migdal, W.; Owczarczyk, B.; Kedzia, B.; Holderna-Kedzia, E.; Segiet-Kujawa, E.

    1998-06-01

    Several thousand tons of medical herbs are produced annually by pharmaceutical industry in Poland. This product should be of highest quality and microbial purity. Recently, chemical methods of decontamination are recognized as less safe, thus irradiation technique was chosen to replace them in use. In the Institute of Nuclear Chemistry and Technology the national program on the application of irradiation to the decontamination of medical herbs is in progress now. The purpose of the program is to elaborate, on the basis of research work, the facility standards and technological instructions indispensable for the practice of radiation technology.

  5. TECHNOLOGY VERIFICATION OF COMMERCIALLY AVAILABLE METHODS FOR DECONTAMINATION OF INDOOR SURFACES CONTAMINATED WITH BIOLOGICAL OR CHEMICAL AGENTS

    EPA Science Inventory

    To support the Nation's Homeland Security Program, this U.S. Environmental Protection Agency (EPA) Environmental Technology Verification (ETV) project is conducted to verify the performance of commercially available products, methods, and equipment for decontamination of hard and...

  6. Full Scale Drinking Water System Decontamination at the Water Security Test Bed.

    PubMed

    Szabo, Jeffrey; Hall, John; Reese, Steve; Goodrich, Jim; Panguluri, Sri; Meiners, Greg; Ernst, Hiba

    2018-03-20

    The EPA's Water Security Test Bed (WSTB) facility is a full-scale representation of a drinking water distribution system. In collaboration with the Idaho National Laboratory (INL), EPA designed the WSTB facility to support full-scale evaluations of water infrastructure decontamination, real-time sensors, mobile water treatment systems, and decontamination of premise plumbing and appliances. The EPA research focused on decontamination of 1) Bacillus globigii (BG) spores, a non-pathogenic surrogate for Bacillus anthracis and 2) Bakken crude oil. Flushing and chlorination effectively removed most BG spores from the bulk water but BG spores still remained on the pipe wall coupons. Soluble oil components of Bakken crude oil were removed by flushing although oil components persisted in the dishwasher and refrigerator water dispenser. Using this full-scale distribution system allows EPA to 1) test contaminants without any human health or ecological risk and 2) inform water systems on effective methodologies responding to possible contamination incidents.

  7. Dwell time considerations for large area cold plasma decontamination

    NASA Astrophysics Data System (ADS)

    Konesky, Gregory

    2009-05-01

    Atmospheric discharge cold plasmas have been shown to be effective in the reduction of pathogenic bacteria and spores and in the decontamination of simulated chemical warfare agents, without the generation of toxic or harmful by-products. Cold plasmas may also be useful in assisting cleanup of radiological "dirty bombs." For practical applications in realistic scenarios, the plasma applicator must have both a large area of coverage, and a reasonably short dwell time. However, the literature contains a wide range of reported dwell times, from a few seconds to several minutes, needed to achieve a given level of reduction. This is largely due to different experimental conditions, and especially, different methods of generating the decontaminating plasma. We consider these different approaches and attempt to draw equivalencies among them, and use this to develop requirements for a practical, field-deployable plasma decontamination system. A plasma applicator with 12 square inches area and integral high voltage, high frequency generator is described.

  8. DECONTAMINATION AND BENEFICIAL USE OF DREDGED MATERIALS.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    STERN, E.A.; LODGE, J.; JONES, K.W.

    2000-12-03

    Our group is leading a large-sale demonstration of dredged material decontamination technologies for the New York/New Jersey Harbor. The goal of the project is to assemble a complete system for economic transformation of contaminated dredged material into an environmentally-benign material used in the manufacture of a variety of beneficial use products. This requires the integration of scientific, engineering, business, and policy issues on matters that include basic knowledge of sediment properties, contaminant distribution visualization, sediment toxicity, dredging and dewatering techniques, decontamination technologies, and product manufacturing technologies and marketing. A summary of the present status of the system demonstrations including themore » use of both existing and new manufacturing facilities is given here. These decontamination systems should serve as a model for use in dredged material management plans of regions other than NY/NJ Harbor, such as Long Island Sound, where new approaches to the handling of contaminated sediments are desirable.« less

  9. Decontamination of fluid milk containing Bacillus spores using commercial household products.

    PubMed

    Black, D G; Taylor, T M; Kerr, H J; Padhi, S; Montville, T J; Davidson, P M

    2008-03-01

    Although commercial sanitizers can inactivate bacterial spores in food processing environments, relatively little data exist as to the decontamination of products and surfaces by consumers using commercial household products. Should a large scale bioterrorism incident occur in which consumer food products were contaminated with a pathogenic sporeformer such as Bacillus anthracis, there may be a need to decontaminate these products before disposal as liquid or solid waste. Studies were conducted to test the efficacy of commercial household products for inactivating spores of Bacillus cereus (used as a surrogate for B. anthracis) in vitro and in fluid milk. Validation of the resistance of the B. cereus spores was confirmed with B. anthracis spores. Fifteen commercial products, designed as either disinfectants or sanitizers or as potential sanitizers, were purchased from retail markets. Products selected had one of the following active compounds: NaOCl, HCl, H2O2, acetic acid, quaternary ammonium compounds, ammonium hydroxide, citric acid, isopropanol, NaOH, or pine oil. Compounds were diluted in water (in vitro) or in 2% fat fluid milk, and spores were exposed for up to 6 h. Products containing hypochlorite were most effective against B. cereus spores. Products containing HCl or H2O2 also reduced significant numbers of spores but at a slower rate. The resistance of spores of surrogate B. cereus strains to chlorine-containing compounds was similar to that of B. anthracis spores. Therefore, several household products on the market may be used to decontaminate fluid milk or similar food products contaminated by spores of B. anthracis.

  10. Inactivation of escherichia coli 0157:H7 and Salmonella on mung beans, alfalfa, and other seed types destined for sprout production by using an oxychloro-based sanitizer.

    PubMed

    Kumar, M; Hora, R; Kostrzynska, M; Waites, W M; Warriner, K

    2006-07-01

    The efficacy of a stabilized oxychloro-based food grade sanitizer to decontaminate seeds destined for sprout production has been evaluated. By using mung bean seeds as a model system, it was demonstrated that the sanitizer could be used to inactivate a five-strain cocktail of Escherichia coli O157:H7 or Salmonella introduced onto beans at 10(3) to 10(4) CFU/g. Salmonella was more tolerant to stabilized oxychloro than was E. coli O157:H7, with sanitizer levels of >150 and >50 ppm, respectively, being required to ensure pathogen-free sprouts. The decontamination efficacy was also found to be dependent on treatment time (>8 h optimal) and the seed-to-sanitizer ratio (>1:4 optimal). Stabilized oxychloro treatment did not exhibit phytotoxic effects, as germination and sprout yields were not significantly (P > 0.05) different as compared with untreated controls. Although human pathogens could be effectively eliminated from mung beans, the aerobic plate count of native microflora on sprouts grown from treated seed was not significantly (P > 0.05) different from the controls. The diversity of microbial populations (determined through 16S rRNA denaturing gradient gel electrophoresis analysis) associated with bean sprouts was not significantly affected by the sanitizer treatment. However, it was noted that Klebsiella and Herbasprillum (both common plant endophytes) were absent in sprouts derived from decontaminated seed but were present in control sprouts. When a further range of seed types was evaluated, it was found that alfalfa, cress, flax, and soybean could be decontaminated with the stabilized oxychloro sanitizer. However, the decontamination efficacy with other seed types was less consistent. It appears that the rate of seed germination and putative activity of sanitizer sequestering system(s), in addition to other factors, may limit the efficacy of the decontamination method.

  11. PRACTICAL EXPERIENCES WITH TECHNOLOGIES FOR DECONTAMINATION OF B. ANTHRACIS IN LARGE BUILDINGS.

    EPA Science Inventory

    In the Fall of 2001 a number of buildings were contaminated with B. anthracis (B.A.) from letters processed through United States Postal Service and other mail handling facilities. All of the buildings have now been decontaminated using a variety of technologies. In a number of...

  12. Large-Scale Urban Decontamination; Developments, Historical Examples and Lessons Learned

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rick Demmer

    2007-02-01

    Recent terrorist threats and actual events have lead to a renewed interest in the technical field of large scale, urban environment decontamination. One of the driving forces for this interest is the real potential for the cleanup and removal of radioactive dispersal device (RDD or “dirty bomb”) residues. In response the U. S. Government has spent many millions of dollars investigating RDD contamination and novel decontamination methodologies. Interest in chemical and biological (CB) cleanup has also peaked with the threat of terrorist action like the anthrax attack at the Hart Senate Office Building and with catastrophic natural events such asmore » Hurricane Katrina. The efficiency of cleanup response will be improved with these new developments and a better understanding of the “old reliable” methodologies. Perhaps the most interesting area of investigation for large area decontamination is that of the RDD. While primarily an economic and psychological weapon, the need to cleanup and return valuable or culturally significant resources to the public is nonetheless valid. Several private companies, universities and National Laboratories are currently developing novel RDD cleanup technologies. Because of its longstanding association with radioactive facilities, the U. S. Department of Energy National Laboratories are at the forefront in developing and testing new RDD decontamination methods. However, such cleanup technologies are likely to be fairly task specific; while many different contamination mechanisms, substrate and environmental conditions will make actual application more complicated. Some major efforts have also been made to model potential contamination, to evaluate both old and new decontamination techniques and to assess their readiness for use. Non-radioactive, CB threats each have unique decontamination challenges and recent events have provided some examples. The U. S. Environmental Protection Agency (EPA), as lead agency for these emergency cleanup responses, has a sound approach for decontamination decision-making that has been applied several times. The anthrax contamination at the U. S. Hart Senate Office Building and numerous U. S. Post Office facilities are examples of employing novel technical responses. Decontamination of the Hart Office building required development of a new approach for high level decontamination of biological contamination as well as techniques for evaluating the technology effectiveness. The World Trade Center destruction also demonstrated the need for, and successful implementation of, appropriate cleanup methodologies. There are a number of significant lessons that can be gained from a look at previous large scale cleanup projects. Too often we are quick to apply a costly “package and dispose” method when sound technological cleaning approaches are available. Understanding historical perspectives, advanced planning and constant technology improvement are essential to successful decontamination.« less

  13. Effects of local-scale decontamination in a secondary forest contaminated after the Fukushima nuclear power plant accident.

    PubMed

    Ayabe, Yoshiko; Hijii, Naoki; Takenaka, Chisato

    2017-09-01

    We investigated whether local-scale decontamination (removal of the litter layer, superficial soil layer, and understory) in a secondary forest contaminated by the Fukushima nuclear power plant accident reduced 137 Cs contamination of the soil and litter. We also measured 137 Cs concentrations in plants and in the web-building spider Nephila clavata (Nephilidae: Arachnida), as an indicator species, to examine 137 Cs contamination in arthropods. One month after decontamination, the total 137 Cs contamination (soil + litter) was reduced by 20% (100 kBq·m -2 ) relative to that in an adjacent untreated (i.e., contaminated) area, which was however not statistically significant. Four months after decontamination, 137 Cs in the decontaminated area had increased to a level similar to those in the untreated area, and the air radiation dose in the decontaminated area was about 2.1 μSv·h -1 , significantly higher than that in the untreated area (1.9 μSv·h -1 ). This may have been attributed to a torrential rain event. Although no statistically significant reduction was observed, most spiders had a lower 137 Cs contamination than that before the decontamination. This implied that the decontamination may have reduced 137 Cs transfer from soil via litter to N. clavata through the detrital food chains, but may not have reduced the amount of 137 Cs transfer through grazing food chains because the concentration of 137 Cs in living tree leaves was not reduced by the decontamination. In autumn, about 2 kBq·m -2 of 137 Cs was supplied from foliage to the ground by litterfall. The results suggested that removal of the litter and superficial soil layers in a contaminated forest may be ineffective. The present study suggests that the local-scale decontamination in a secondary forest had no effect on the reduction of 137 Cs contamination in the treated area. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Use of vaporized hydrogen peroxide decontamination during an outbreak of multidrug-resistant Acinetobacter baumannii infection at a long-term acute care hospital.

    PubMed

    Ray, Amy; Perez, Federico; Beltramini, Amanda M; Jakubowycz, Marta; Dimick, Patricia; Jacobs, Michael R; Roman, Kathy; Bonomo, Robert A; Salata, Robert A

    2010-12-01

    To describe vaporized hydrogen peroxide (VHP) as an adjuvant in the control of multidrug-resistant (MDR) Acinetobacter baumannii infection in a long-term acute care hospital (LTACH) and to describe the risk factors for acquisition of MDR A. baumannii infection in the LTACH population. Outbreak investigation, case-control study, and before-after intervention trial. A 54-bed LTACH affiliated with a tertiary care center in northeastern Ohio. Investigation of outbreak with clinical and environmental cultures, antimicrobial susceptibility testing, polymerase chain reaction assay of repetitive chromosomal elements to type strains, and case-control study; and intervention consisting of comprehensive infection control measures and VHP environmental decontamination. Thirteen patients infected or colonized with MDR A. baumannii were identified from January 2008 through June 2008. By susceptibility testing, 10 (77%) of the 13 isolates were carbapenem-resistant. MDR A. baumannii was found in wound samples, blood, sputum, and urine. Wounds were identified as a risk factor for MDR A. baumannii colonization. Ventilator-associated pneumonia was the most common clinical syndrome caused by the pathogen, and the associated mortality was 14% (2 of the 13 case patients died). MDR A. baumannii was found in 8 of 93 environmental samples, including patient rooms and a wound care cart; environmental and clinical cultures were genetically related. Environmental cultures were negative immediately after VHP decontamination and both 24 hours and 1 week after VHP decontamination. Nosocomial acquisition of the pathogen in the LTACH ceased after VHP intervention. When patients colonized with MDR A. baumannii reoccupied rooms, environmental contamination recurred. Environmental decontamination using VHP combined with comprehensive infection control measures interrupted nosocomial transmission of MDR A. baumannii in an LTACH. The application of this novel approach to halt the transmission of MDR A. baumannii warrants further investigation.

  15. Fighting Ebola with novel spore decontamination technologies for the military

    DOE PAGES

    Doona, Christopher J.; Feeherry, Florence E.; Kustin, Kenneth; ...

    2015-08-12

    Recently, global public health organizations such as Doctors without Borders (MSF), the World Health Organization (WHO), Public Health Canada, National Institutes of Health (NIH), and the U.S. government developed and deployed Field Decontamination Kits (FDKs), a novel, lightweight, compact, reusable decontamination technology to sterilize Ebola-contaminated medical devices at remote clinical sites lacking infra-structure in crisis-stricken regions of West Africa (medical waste materials are placed in bags and burned). Here, the basis for effectuating sterilization with FDKs is chlorine dioxide (ClO 2) produced from a patented invention developed by researchers at the US Army Natick Soldier RD&E Center (NSRDEC) and commercializedmore » as a dry mixed-chemical for bacterial spore decontamination.« less

  16. Fighting Ebola with novel spore decontamination technologies for the military

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Doona, Christopher J.; Feeherry, Florence E.; Kustin, Kenneth

    Recently, global public health organizations such as Doctors without Borders (MSF), the World Health Organization (WHO), Public Health Canada, National Institutes of Health (NIH), and the U.S. government developed and deployed Field Decontamination Kits (FDKs), a novel, lightweight, compact, reusable decontamination technology to sterilize Ebola-contaminated medical devices at remote clinical sites lacking infra-structure in crisis-stricken regions of West Africa (medical waste materials are placed in bags and burned). Here, the basis for effectuating sterilization with FDKs is chlorine dioxide (ClO 2) produced from a patented invention developed by researchers at the US Army Natick Soldier RD&E Center (NSRDEC) and commercializedmore » as a dry mixed-chemical for bacterial spore decontamination.« less

  17. Efficacy of high-intensity pulsed light for the microbiological decontamination of chicken, associated packaging, and contact surfaces.

    PubMed

    Haughton, Pippa N; Lyng, James G; Morgan, Desmond J; Cronin, Denis A; Fanning, Seamus; Whyte, Paul

    2011-01-01

    The efficacy of high-intensity light pulse (HILP) technology (3 Hz, maximum of 505 J/pulse, and a pulse duration of 360 μs) for the decontamination of raw chicken and associated packaging and surface materials was investigated. Its ability to reduce microbial counts on raw chicken through plastic films was also examined. Complete inactivation of Campylobacter spp., Escherichia coli, and Salmonella Enteritidis in liquid was achieved after 30 sec HILP treatment. Reductions of 3.56, 4.69, and 4.60 log₁₀ cfu/cm²) were observed after 5 sec HILP treatment of Campylobacter jejuni, E. coli, and Salmonella Enteritidis inoculated onto packaging materials and contact surfaces, respectively. The greatest reductions on inoculated chicken skin were 1.22, 1.69, and 1.27 log₁₀ cfu/g for C. jejuni, E. coli, and Salmonella Enteritidis, respectively. Corresponding reductions on inoculated skinless breast meat were 0.96, 1.13, and 1.35 log₁₀ cfu/g. The effectiveness of HILP treatment for reducing microbial levels on chicken increased as the film thickness decreased. HILP treatments of 2 sec did not significantly affect the color of raw chicken although treatments of 30 sec impacted color. This study has shown HILP to be an effective method for the decontamination of packaging and surface materials. Additionally, it has demonstrated the potential of HILP to be used as a decontamination method for packaged chicken.

  18. Fighting Ebola with novel spore decontamination technologies for the military.

    PubMed

    Doona, Christopher J; Feeherry, Florence E; Kustin, Kenneth; Olinger, Gene G; Setlow, Peter; Malkin, Alexander J; Leighton, Terrance

    2015-01-01

    Recently, global public health organizations such as Doctors without Borders (MSF), the World Health Organization (WHO), Public Health Canada, National Institutes of Health (NIH), and the U.S. government developed and deployed Field Decontamination Kits (FDKs), a novel, lightweight, compact, reusable decontamination technology to sterilize Ebola-contaminated medical devices at remote clinical sites lacking infra-structure in crisis-stricken regions of West Africa (medical waste materials are placed in bags and burned). The basis for effectuating sterilization with FDKs is chlorine dioxide (ClO2) produced from a patented invention developed by researchers at the US Army Natick Soldier RD&E Center (NSRDEC) and commercialized as a dry mixed-chemical for bacterial spore decontamination. In fact, the NSRDEC research scientists developed an ensemble of ClO2 technologies designed for different applications in decontaminating fresh produce; food contact and handling surfaces; personal protective equipment; textiles used in clothing, uniforms, tents, and shelters; graywater recycling; airplanes; surgical instruments; and hard surfaces in latrines, laundries, and deployable medical facilities. These examples demonstrate the far-reaching impact, adaptability, and versatility of these innovative technologies. We present herein the unique attributes of NSRDEC's novel decontamination technologies and a Case Study of the development of FDKs that were deployed in West Africa by international public health organizations to sterilize Ebola-contaminated medical equipment. FDKs use bacterial spores as indicators of sterility. We review the properties and structures of spores and the mechanisms of bacterial spore inactivation by ClO2. We also review mechanisms of bacterial spore inactivation by novel, emerging, and established non-thermal technologies for food preservation, such as high pressure processing, irradiation, cold plasma, and chemical sanitizers, using an array of Bacillus subtilis mutants to probe mechanisms of spore germination and inactivation. We employ techniques of high-resolution atomic force microscopy and phase contrast microscopy to examine the effects of γ-irradiation on bacterial spores of Bacillus anthracis, Bacillus thuringiensis, and Bacillus atrophaeus spp. and of ClO2 on B. subtilis spores, and present in detail assays using spore bio-indicators to ensure sterility when decontaminating with ClO2.

  19. Fighting Ebola with novel spore decontamination technologies for the military

    PubMed Central

    Doona, Christopher J.; Feeherry, Florence E.; Kustin, Kenneth; Olinger, Gene G.; Setlow, Peter; Malkin, Alexander J.; Leighton, Terrance

    2015-01-01

    Recently, global public health organizations such as Doctors without Borders (MSF), the World Health Organization (WHO), Public Health Canada, National Institutes of Health (NIH), and the U.S. government developed and deployed Field Decontamination Kits (FDKs), a novel, lightweight, compact, reusable decontamination technology to sterilize Ebola-contaminated medical devices at remote clinical sites lacking infra-structure in crisis-stricken regions of West Africa (medical waste materials are placed in bags and burned). The basis for effectuating sterilization with FDKs is chlorine dioxide (ClO2) produced from a patented invention developed by researchers at the US Army Natick Soldier RD&E Center (NSRDEC) and commercialized as a dry mixed-chemical for bacterial spore decontamination. In fact, the NSRDEC research scientists developed an ensemble of ClO2 technologies designed for different applications in decontaminating fresh produce; food contact and handling surfaces; personal protective equipment; textiles used in clothing, uniforms, tents, and shelters; graywater recycling; airplanes; surgical instruments; and hard surfaces in latrines, laundries, and deployable medical facilities. These examples demonstrate the far-reaching impact, adaptability, and versatility of these innovative technologies. We present herein the unique attributes of NSRDEC’s novel decontamination technologies and a Case Study of the development of FDKs that were deployed in West Africa by international public health organizations to sterilize Ebola-contaminated medical equipment. FDKs use bacterial spores as indicators of sterility. We review the properties and structures of spores and the mechanisms of bacterial spore inactivation by ClO2. We also review mechanisms of bacterial spore inactivation by novel, emerging, and established non-thermal technologies for food preservation, such as high pressure processing, irradiation, cold plasma, and chemical sanitizers, using an array of Bacillus subtilis mutants to probe mechanisms of spore germination and inactivation. We employ techniques of high-resolution atomic force microscopy and phase contrast microscopy to examine the effects of γ-irradiation on bacterial spores of Bacillus anthracis, Bacillus thuringiensis, and Bacillus atrophaeus spp. and of ClO2 on B. subtilis spores, and present in detail assays using spore bio-indicators to ensure sterility when decontaminating with ClO2. PMID:26322021

  20. Prevention, Treatment and Tiagnosis of Pathogenic Infections by Using Pulsed Light Radiation Propagating Through Metamaterials

    NASA Astrophysics Data System (ADS)

    Enaki, N.; Paslari, T.; Turcan, M.; Bazgan, S.; Ristoscu, C.; Mihailescu, I. N.

    2018-06-01

    We propose novel optical methods for prevention, treatment and diagnosis of infections by pathogens using metamaterials with various geometries consisting of microspheres (i.e. photonic crystals, photonic molecules) and optical fibers structures. Around the adjacent elements of metamaterials appear the evanescent zones of propagated pulsed light radiation overlapping each other. This effect gives us the possibility to significantly increase the decontamination volume especially in non-transparent media. The parking geometries of microspheres and optical fibers ensure the efficient contact zone between the pulsed light radiation with contaminated materials (gases, liquids, tissues, implant surfaces). The penetration depth of evanescent field in contaminated materials can achieve values comparable with pathogens dimensions. We propose an attractive antimicrobial strategy using combined action of ultrashort pulses with different frequencies and pulse duration to achieve the selective decontamination of microorganisms with minimal effects on the components of human cells and tissues. We take into consideration the intrinsic symmetries of microorganisms protein structures (inclusive virus capsids) and their possible resonant excitation in double frequencies induced Raman scattering. The development of nonlinear models of the excitation of vibration modes of biomolecules of viruses and bacteria are revised taking into consideration the multi-mode aspects of interaction of pulsed light with excited biomolecules of pathogens. This method opens new possibilities in decontamination and diagnosis of the new collective processes, which can take place in viruses, bacteria, or other cellular structures under the action of external light pulses. Exponential distribution of radiation in evanescent zone gives us the possibility to capture and trap the viruses and bacteria along the optical fibers or/and microsphere surfaces.

  1. Evaluation of low-dose irradiation on microbiological quality of white carrots and string beans

    NASA Astrophysics Data System (ADS)

    Koike, Amanda C. R.; Santillo, Amanda G.; Rodrigues, Flávio T.; Duarte, Renato C.; Villavicencio, Anna Lucia C. H.

    2012-08-01

    The minimally processed food provided the consumer with a product quality, safety and practicality. However, minimal processing of food does not reduce pathogenic population of microorganisms to safe levels. Ionizing radiation used in low doses is effective to maintain the quality of food, reducing the microbiological load but rather compromising the nutritional values and sensory property. The association of minimal processing with irradiation could improve the quality and safety of product. The purpose of this study was to evaluate the effectiveness of low-doses of ionizing radiation on the reduction of microorganisms in minimally processed foods. The results show that the ionizing radiation of minimally processed vegetables could decontaminate them without several changes in its properties.

  2. Use of the probiotic Lactobacillus plantarum 299 to reduce pathogenic bacteria in the oropharynx of intubated patients: a randomised controlled open pilot study

    PubMed Central

    Klarin, Bengt; Molin, Göran; Jeppsson, Bengt; Larsson, Anders

    2008-01-01

    Introduction Ventilator-associated pneumonia (VAP) is usually caused by aspiration of pathogenic bacteria from the oropharynx. Oral decontamination with antiseptics, such as chlorhexidine (CHX) or antibiotics, has been used as prophylaxis against this complication. We hypothesised that the probiotic bacteria Lactobacillus plantarum 299 (Lp299) would be as efficient as CHX in reducing the pathogenic bacterial load in the oropharynx of tracheally intubated, mechanically ventilated, critically ill patients. Methods Fifty critically ill patients on mechanical ventilation were randomised to either oral mechanical cleansing followed by washing with 0.1% CHX solution or to the same cleansing procedure followed by oral application of an emulsion of Lp299. Samples for microbiological analyses were taken from the oropharynx and trachea at inclusion and at defined intervals thereafter. Results Potentially pathogenic bacteria that were not present at inclusion were identified in oropharyngeal samples from eight of the patients treated with Lp299 and 13 of those treated with CHX (p = 0.13). Analysis of tracheal samples yielded similar results. Lp299 was recovered from the oropharynx of all patients in the Lp299 group. Conclusions In this pilot study, we found no difference between the effect of Lp299 and CHX used in oral care procedures, when we examined the effects of those agents on colonisation of potentially pathogenic bacteria in the oropharynx of intubated, mechanically ventilated patients. PMID:18990201

  3. What's hot in animal biosafety?

    PubMed

    Richmond, J Y; Hill, R H; Weyant, R S; Nesby-O'Dell, S L; Vinson, P E

    2003-01-01

    In recent years, the emergence or re-emergence of critical issues in infectious disease and public health has presented new challenges and opportunities for laboratory animal care professionals. The re-emergence of bioterrorism as a threat activity of individuals or small groups has caused a heightened awareness of biosecurity and improved biosafety. The need for animal work involving high-risk or high-consequence pathogens and for arthropod-borne diseases has stimulated renewed interest in animal biosafety matters, particularly for work in containment. Application of these principles to animals retained in outdoor environments has been a consequence of disease eradication programs. The anticipated global eradication of wild poliovirus has prompted the promulgation of new biosafety guidelines for future laboratory and animal work. Increased concern regarding the use of biologically derived toxins and hazardous chemicals has stimulated a new categorization of facility containment based on risk assessment. Recognition that prion disease agents and other high-consequence pathogens require safe handling and thorough destruction during terminal decontamination treatment has led to the development of new biosafety guidelines and technologies. The implementation of these guidelines and technologies will promote state-of-the-art research while minimizing risk to laboratory animals, researchers, and the environment.

  4. Bacteriophage Applications for Food Production and Processing

    PubMed Central

    Moye, Zachary D.; Woolston, Joelle; Sulakvelidze, Alexander

    2018-01-01

    Foodborne illnesses remain a major cause of hospitalization and death worldwide despite many advances in food sanitation techniques and pathogen surveillance. Traditional antimicrobial methods, such as pasteurization, high pressure processing, irradiation, and chemical disinfectants are capable of reducing microbial populations in foods to varying degrees, but they also have considerable drawbacks, such as a large initial investment, potential damage to processing equipment due to their corrosive nature, and a deleterious impact on organoleptic qualities (and possibly the nutritional value) of foods. Perhaps most importantly, these decontamination strategies kill indiscriminately, including many—often beneficial—bacteria that are naturally present in foods. One promising technique that addresses several of these shortcomings is bacteriophage biocontrol, a green and natural method that uses lytic bacteriophages isolated from the environment to specifically target pathogenic bacteria and eliminate them from (or significantly reduce their levels in) foods. Since the initial conception of using bacteriophages on foods, a substantial number of research reports have described the use of bacteriophage biocontrol to target a variety of bacterial pathogens in various foods, ranging from ready-to-eat deli meats to fresh fruits and vegetables, and the number of commercially available products containing bacteriophages approved for use in food safety applications has also been steadily increasing. Though some challenges remain, bacteriophage biocontrol is increasingly recognized as an attractive modality in our arsenal of tools for safely and naturally eliminating pathogenic bacteria from foods. PMID:29671810

  5. Comparison of gamma and electron beam irradiation in reducing populations of E. coli artificially inoculated on Mung Bean, clover and Fenugreek Seeds, and affecting germination and growth of seeds

    USDA-ARS?s Scientific Manuscript database

    Sprouts have frequently been implicated in outbreaks of foodborne illnesses, mostly due to contaminated seeds. Intervention technologies to decontaminate seeds without affecting sprout yield are needed. In the present study, we compared gamma rays with electron beam in inactivating E. coli artifici...

  6. TECHNOLOGY TRANSFER ENVIRONMENTAL REGULATIONS AND TECHNOLOGY : CONTROL OF PATHOGENS IN MUNICIPAL WASTEWATER SLUDGE

    EPA Science Inventory

    This 71 - page Technology Transfer Environmental Regulations and echnology publication describes the Federal requirements promulgated in 1979 for reducing pathogens n wastewater sludge and provides guidance in determining whether individual sludge treatment andated or particular ...

  7. Decontamination of Drinking Water Infrastructure ...

    EPA Pesticide Factsheets

    Technical Brief This study examines the effectiveness of decontaminating corroded iron and cement-mortar coupons that have been contaminated with spores of Bacillus atrophaeus subsp. globigii (B. globigii), which is often used as a surrogate for pathogenic B. anthracis (anthrax) in disinfection studies. Bacillus spores are persistent on common drinking water material surfaces like corroded iron, requiring physical or chemical methods to decontaminate the infrastructure. In the United States, free chlorine and monochloramine are the primary chemical disinfectants used by the drinking water industry to inactivate microorganisms. Flushing is also a common, easily implemented practice in drinking water distribution systems, although large volumes of contaminated water needing treatment could be generated. Identifying readily available alternative disinfectant formulations for infrastructure decontamination could give water utilities options for responding to specific types of contamination events. In addition to presenting data on flushing alone, which demonstrated the persistence of spores on water infrastructure in the absence of high levels of disinfectants, data on acidified nitrite, chlorine dioxide, free chlorine, monochloramine, ozone, peracetic acid, and followed by flushing are provided.

  8. Advanced Decontamination Technologies: High Hydrostatic Pressure on Meat Products

    NASA Astrophysics Data System (ADS)

    Garriga, Margarita; Aymerich, Teresa

    The increasing demand for “natural” foodstuffs, free from chemical additives, and preservatives has triggered novel approaches in food technology developments. In the last decade, practical use of high-pressure processing (HPP) made this emerging non-thermal technology very attractive from a commercial point of view. Despite the fact that the investment is still high, the resulting value-added products, with an extended and safe shelf-life, will fulfil the wishes of consumers who prefer preservative-free minimally processed foods, retaining sensorial characteristics of freshness. Moreover, unlike thermal treatment, pressure treatment is not time/mass dependant, thus reducing the time of processing.

  9. Decontamination Equipment Standards Workshop for Civilian First Responders

    DTIC Science & Technology

    2009-12-01

    Hazardous Materials Decontamination Radiological Survey Nuclear Chemical 16. SECURITY CLASSIFICATION OF: a. REPORT u b. ABSTRACT u c. THIS...Washington, DC) sponsored the production of this material under an Interagency Agreement with the National Institute of Standards and Technology...responders currently use wet decontamination (i.e., soap and water) to remove contamination from personnel, the standard will not be specific to the

  10. Assessment, evaluation, and testing of technologies for environmental restoration, decontamination, and decommissioning and high level waste management. Progress report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Uzochukwu, G.A.

    1997-12-31

    Nuclear and commercial non-nuclear technologies that have the potential of meeting the environmental restoration, decontamination and decommissioning, and high-level waste management objectives are being assessed and evaluated. A detailed comparison of innovative technologies available will be performed to determine the safest and most economical technology for meeting these objectives. Information derived from this effort will be matched with the multi-objectives of the environmental restoration, decontamination and decommissioning, and high-level waste management effort to ensure that the best, most economical, and the safest technologies are used in decision making at USDOE-SRS. Technology-related variables will be developed and the resulting data formattedmore » and computerized for multimedia systems. The multimedia system will be made available to technology developers and evaluators to ensure that the best, most economical, and the safest technologies are used in decision making at USDOE-SRS. Technology-related variables will be developed and the resulting data formatted and computerized for multimedia systems. The multimedia system will be made available to technology developers and evaluators to ensure that the safest and most economical technologies are developed for use at SRS and other DOE sites.« less

  11. Comparison of the effectiveness in bacterial decontamination between chlorhexidine gluconate and povidone-iodine solution in foot and ankle: a pilot study.

    PubMed

    Rugpolmuang, Likit; Thanabodeethada, Roongroj; Riansuwan, Kongkhet

    2012-09-01

    The decontamination for foot and ankle surgery should be considered as a special preparation due to higher rate of bacterial contamination. The footwear and humidity is also the issue of interest especially in tropical country. The contamination before surgery should be reduced to avoid the infection. The effectiveness of antiseptics and special condition for the foot and ankle surgery should be elucidated for better medical care. The twenty volunteers were included in the present study. In group 1, the foot was scrubbed with 7.5% Povidone-lodine and painted with 10% Povidone-lodine solution. In group II, the foot was scrubbed with Chlorhexidine gluconate scrub and painted with 2% Chlorhexidine gluconate in 70% alcohol. At the beginning and end of the preparation, specimens were taking from all toes, nailfold, interdigital web spaces. These samples were sent for aerobic bacterial cultures. The results were interpreted as positive or negative cultivation and the number of bacterial colonies. All of the samples from 40 feet were collected; In Group I, positive culture was 5 samples (25%). In Group II, positive culture was 2 samples (10%) (p = 0.2). The Chlorhexidine gluconate and Povidone-lodine are effective in reduction the number of bacterial colonization. The steps of preparation before surgery also play an important role in eliminating the pathogenic bacteria. Both antiseptics were found no significant different in efficacy of pathogenic bacteria reduction.

  12. Binding affinity and decontamination of dermal decontamination gel to model chemical warfare agent simulants.

    PubMed

    Cao, Yachao; Elmahdy, Akram; Zhu, Hanjiang; Hui, Xiaoying; Maibach, Howard

    2018-05-01

    Six chemical warfare agent simulants (trimethyl phosphate, dimethyl adipate, 2-chloroethyl methyl sulfide, diethyl adipate, chloroethyl phenyl sulfide and diethyl sebacate) were studied in in vitro human skin to explore relationship between dermal penetration/absorption and the mechanisms of simulant partitioning between stratum corneum (SC) and water as well as between dermal decontamination gel (DDGel) and water. Both binding affinity to and decontamination of simulants using DDGel were studied. Partition coefficients of six simulants between SC and water (Log P SC/w ) and between DDGel and water (Log P DDGel/w ) were determined. Results showed that DDGel has a similar or higher binding affinity to each simulant compared to SC. The relationship between Log P octanol/water and Log P SC/w as well as between Log P octanol/water and Log P DDGel/w demonstrated that partition coefficient of simulants correlated to their lipophilicity or hydrophilicity. Decontamination efficiency results with DDGel for these simulants were consistent with binding affinity results. Amounts of percentage dose of chemicals in DDGel of trimethyl phosphate, dimethyl adipate, 2-chloroethyl methyl sulfide, diethyl adipate, chloroethyl phenyl sulfide and diethyl sebacate were determined to be 61.15, 85.67, 75.91, 53.53, 89.89 and 76.58, with corresponding amounts absorbed in skin of 0.96, 0.65, 1.68, 0.72, 0.57 and 1.38, respectively. In vitro skin decontamination experiments coupled with a dermal absorption study demonstrated that DDGel can efficiently remove chemicals from skin surface, back-extract from the SC, and significantly reduced chemical penetration into skin or systemic absorption for all six simulants tested. Therefore, DDGel offers a great potential as a NextGen skin Decon platform technology for both military and civilian use. Copyright © 2018 John Wiley & Sons, Ltd.

  13. The pharmacological activity of medical herbs after microbiological decontamination by irradiation

    NASA Astrophysics Data System (ADS)

    Owczarczyk, H. B.; Migdał, W.; K ȩdzia, B.

    2000-03-01

    In the Institute of Nuclear Chemistry and Technology research on microbiological decontamination of medicinal herbs by irradiation has been carried out since 1996. It was shown that using ionizing radiation (a dose of 10 kGy) can obtain satisfactory results of microbiological decontamination of these products. The content of essential biologically active substances such as essential oils, flavonoids, glycosides, anthocyans, antra-compounds, poliphenoloacids, triterpene saponins, oleanosides and plants mucus did not change significantly after irradiation. Pharmacological activity of medicinal herbs has been found satisfactory after microbiological decontamination by irradiation.

  14. Determination of the profit rate of plasma treated production in the food sector

    NASA Astrophysics Data System (ADS)

    Gok, Elif Ceren; Uygun, Emre; Eren, Esin; Oksuz, Lutfi; Uygun Oksuz, Aysegul

    2017-10-01

    Recently, plasma is one of an emerging, green processing technologies used for diverse applications especially food industry. Plasma treatment proposes diverse opportunities in food industry such as surface decontamination, modification of surface properties and improvement in mass transfer with respect for foods and food-related compounds. Sometimes manufacturers use chemical treatment to demolish pathogenic flora, but its capabilities are rather limited. New methods of food sterilization consisting of ionizing radiation, exposure to magnetic fields, high-power ultrasonic treatment are needed expensive equipment or have not yet been developed for industrial use. Plasma could be used for the above mentioned reasons. In this study, the profit rate of plasma treated production in food sector was calculated.

  15. Decontamination and disposal of PCB wastes.

    PubMed Central

    Johnston, L E

    1985-01-01

    Decontamination and disposal processes for PCB wastes are reviewed. Processes are classed as incineration, chemical reaction or decontamination. Incineration technologies are not limited to the rigorous high temperature but include those where innovations in use of oxident, heat transfer and residue recycle are made. Chemical processes include the sodium processes, radiant energy processes and low temperature oxidations. Typical processing rates and associated costs are provided where possible. PMID:3928363

  16. A systematic methodology for selecting decontamination strategies following a biocontamination event.

    PubMed

    Krauter, Paula; Edwards, Donna; Yang, Lynn; Tucker, Mark

    2011-09-01

    Decontamination and recovery of a facility or outdoor area after a wide-area biological incident involving a highly persistent agent (eg, Bacillus anthracis spores) is a complex process that requires extensive information and significant resources, which are likely to be limited, particularly if multiple facilities or areas are affected. This article proposes a systematic methodology for evaluating information to select the decontamination or alternative treatments that optimize use of resources if decontamination is required for the facility or area. The methodology covers a wide range of approaches, including volumetric and surface decontamination, monitored natural attenuation, and seal and abandon strategies. A proposed trade-off analysis can help decision makers understand the relative appropriateness, efficacy, and labor, skill, and cost requirements of the various decontamination methods for the particular facility or area needing treatment--whether alone or as part of a larger decontamination effort. Because the state of decontamination knowledge and technology continues to evolve rapidly, the methodology presented here is designed to accommodate new strategies and materials and changing information.

  17. The feasibility study of hot cell decontamination by the PFC spray method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hui-Jun Won; Chong-Hun Jung; Jei-Kwon Moon

    2008-01-15

    The characteristics of per-fluorocarbon compounds (PFC) are colorless, non-toxic, easily vaporized and nonflammable. Also, some of them are liquids of a high density, low surface tension, low latent heat and low specific heat. These particular chemical and physical properties of fluoro-organic compounds permit their use in very different fields such as electronics, medicine, tribology, nuclear and material science. The Sonatol process was developed under a contract with the DOE. The Sonatol process uses an ultrasonic agitation in a PFC solution that contains a fluorinated surfactant to remove radioactive particles from surfaces. Filtering the suspended particles allows the solutions to bemore » reused indefinitely. They applied the Sonatol process to the decontamination of a heterogeneous legacy Pu-238 waste that exhibited an excessive hydrogen gas generation, which prevents a transportation of such a waste to a Waste Isolation Pilot Plant. Korea Atomic Energy Research Institute (KAERI) is developing dry decontamination technologies applicable to a decontamination of a highly radioactive area loosely contaminated with radioactive particles. This contamination has occurred as a result of an examination of a post-irradiated material or the development of the DUPIC process. The dry decontamination technologies developed are the carbon dioxide pellet spray method and the PFC spray method. As a part of the project, PFC ultrasonic decontamination technology was developed in 2004. The PFC spray decontamination method which is based on the test results of the PFC ultrasonic method has been under development since 2005. The developed PFC spray decontamination equipment consists of four modules (spray, collection, filtration and distillation). Vacuum cup of the collection module gathers the contaminated PFC solution, then the solution is moved to the filtration module and it is recycled. After a multiple recycling of the spent PFC solution, it is purified in the distillation module. A performance test on each module was executed and the results have been reported. A combined test of the four modules, however, has not been performed as yet. The main objective of the present study is to demonstrate the feasibility of the full PFC spray decontamination process. Decontamination of the inside of the IMEF hot cell by the PFC spray method was also performed. PFC spray decontamination process was demonstrated by using a surrogate wall contaminated with Eu{sub 2}O{sub 3} powder. The spray pressure was 41 kgf/cm{sup 2}, the orifice diameter was 0.2 mm and the spray velocity was 0.2 L/min. And, the decontaminated area was 100 cm{sup 2}. From previous test results, we found that the decontamination factor of the PFC spray method was in the range from 9.6 to 62.4. When the decontamination efficiency of Co-60 was high, then the decontamination efficiency of Cs-137 was also high. As the surface roughness of the specimen increased, the PFC spray decontamination efficiency decreased. Inferring from the previous results, the surface of the surrogate wall was cleaned by the PFC spray method. The vacuum cup of the collection module operated well and gathered more than 99 % of the PFC solution. Also, filtration and distillation modules operated well. All the filtered PFC solution flowed to the storage chamber where some of the PFC solution was distilled. The coolant of the distillation module was a dry ice. And, the recycled solution was transferred to the spray module by a high pressure pump. To evaluate the PFC spray decontamination efficiency, a smear device was fabricated and operated by a manipulator. Before and after decontamination, a smear test was performed. The tested area was 100 cm{sup 2} and the radioactivity was estimated indirectly by measuring the radioactivity of the filter paper. The average decontamination factor was in the range between 10 and 15. One application time was 2 minutes. The sprayed PFC solution was collected by the vacuum cup and it was stored in the collection equipment. After the termination of the decontamination test, the flexible hose was cut near a toboggan. The collection equipment that contained the spent PFC solution, vacuum cup, spray nozzle and the flexible hose was stored in a radioactive waste storage tank. A feasibility study for the PFC spray decontamination method for an application to a hot cell surface was performed. The decontamination equipment that consisted of four modules operated well in the hot cell. The collection module gathered the sprayed PFC solution. The solution was purified in the filtration or distillation modules. The main characteristic of the distillation module is the use of dry ice as a coolant. The decontamination factor of IMEF hot cell was in the range from 10 to 15. It was difficult to measure the radioactivity accurately at a given time. We, however, concluded that the PFC spray decontamination method is a promising technology. It generated a small amount of secondary waste and used a non-toxic and non-conducting material. Decontamination work was performed with a little loss of the main decontamination agent. Based on the test results, we are developing an improved PFC spray decontamination process.« less

  18. Efficacy of scalp hair decontamination following exposure to vapours of sulphur mustard simulants 2-chloroethyl ethyl sulphide and methyl salicylate.

    PubMed

    Spiandore, Marie; Piram, Anne; Lacoste, Alexandre; Prevost, Philippe; Maloni, Pascal; Torre, Franck; Asia, Laurence; Josse, Denis; Doumenq, Pierre

    2017-04-01

    Chemical warfare agents are an actual threat and victims' decontamination is a main concern when mass exposure occurs. Skin decontamination with current protocols has been widely documented, as well as surface decontamination. However, considering hair ability to trap chemicals in vapour phase, we investigated hair decontamination after exposure to sulphur mustard simulants methyl salicylate and 2-chloroethyl ethyl sulphide. Four decontamination protocols were tested on hair, combining showering and emergency decontamination (use of Fuller's earth or Reactive Skin Decontamination Lotion RSDL ® ). Both simulants were recovered from hair after treatment, but contents were significantly reduced (42-85% content allowance). Showering alone was the least efficient protocol. Concerning 2-chloroethyl ethyl sulphide, protocols did not display significant differences in decontamination efficacy. For MeS, use of emergency decontaminants significantly increased showering efficacy (10-20% rise), underlining their usefulness before thorough decontamination. Our results highlighted the need to extensively decontaminate hair after chemical exposure. Residual amounts after decontamination are challenging, as their release from hair could lead to health issues. Copyright © 2016. Published by Elsevier B.V.

  19. Behaviour of co-inoculated pathogenic and spoilage bacteria on poultry following several decontamination treatments.

    PubMed

    Alonso-Hernando, Alicia; Capita, Rosa; Alonso-Calleja, Carlos

    2012-10-01

    The potential of chemical decontaminants to cause harmful effects on human health is among the causes of the rejection of antimicrobial treatments for removing surface contamination from poultry carcasses in the European Union. This study was undertaken to determine whether decontaminants might give a competitive advantage to pathogenic bacteria on poultry and involve a potential risk to consumer. A total of 144 chicken legs were co-inoculated with similar concentrations of pathogenic bacteria (Listeria monocytogenes, Staphylococcus aureus, Salmonella enterica serotype Enteritidis or Escherichia coli) and spoilage bacteria (Brochothrix thermosphacta or Pseudomonas fluorescens). Samples were dipped for 15min in solutions (w/v) of trisodium phosphate (12%; TSP), acidified sodium chlorite (1200ppm; ASC), citric acid (2%; CA), peroxyacids (220ppm; PA) or chlorine dioxide (50ppm; CD), or were left untreated (control). Microbiological analyses were carried out on day 0 and every 24h until day 7 of storage (at 10±1°C). The modified Gompertz equation was used as the primary model to fit observed data. TSP, ASC and CA were effective in extending the lag phase (L, ranging from 1.47±1.34days to 4.06±1.16days) and in decreasing the concentration of bacteria during the stationary phase (D, ranging from 2.46±0.51 log(10) cfu/cm(2) to 8.64±0.53 log(10) cfu/cm(2)), relative to the control samples (L values ranging from 0.59±0.38days and 2.52±2.28days, and D values ranging from 6.32±0.89 log(10) cfu/cm(2) to 9.39±0.39 log(10) cfu/cm(2), respectively). Both on untreated and on most decontaminated samples the overgrowth of spoilage bacteria among the species tested was observed throughout storage, suggesting that spoilage would occur prior to any noteworthy increase in the levels of pathogenic microorganisms. However, L. monocytogenes counts similar to, or higher than, those for spoilage bacteria were observed on samples treated with TSP, ASC or CA, suggesting that these treatments might pose a danger to consumers. However, these results derive from laboratory-based experiments testing artificially-inoculated bacteria. Further investigations of the natural micro-biota of poultry carcasses would be appropriate in order to substantiate these findings. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Pyroprocessing of Light Water Reactor Spent Fuels Based on an Electrochemical Reduction Technology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ohta, Hirokazu; Inoue, Tadashi; Sakamura, Yoshiharu

    A concept of pyroprocessing light water reactor (LWR) spent fuels based on an electrochemical reduction technology is proposed, and the material balance of the processing of mixed oxide (MOX) or high-burnup uranium oxide (UO{sub 2}) spent fuel is evaluated. Furthermore, a burnup analysis for metal fuel fast breeder reactors (FBRs) is conducted on low-decontamination materials recovered by pyroprocessing. In the case of processing MOX spent fuel (40 GWd/t), UO{sub 2} is separately collected for {approx}60 wt% of the spent fuel in advance of the electrochemical reduction step, and the product recovered through the rare earth (RE) removal step, which hasmore » the composition uranium:plutonium:minor actinides:fission products (FPs) = 76.4:18.4:1.7:3.5, can be applied as an ingredient of FBR metal fuel without a further decontamination process. On the other hand, the electroreduced alloy of high-burnup UO{sub 2} spent fuel (48 GWd/t) requires further decontamination of residual FPs by an additional process such as electrorefining even if RE FPs are removed from the alloy because the recovered plutonium (Pu) is accompanied by almost the same amount of FPs in addition to RE. However, the amount of treated materials in the electrorefining step is reduced to {approx}10 wt% of the total spent fuel owing to the prior UO{sub 2} recovery step. These results reveal that the application of electrochemical reduction technology to LWR spent oxide fuel is a promising concept for providing FBR metal fuel by a rationalized process.« less

  1. Defending Against Biological and Chemical Attacks

    DTIC Science & Technology

    2010-08-01

    addition, we field integrated installation consequence management response capabilities to select installations both at home and abroad. Just as...decon- tamination, like self-decontaminating or strippable coat- ings for vehicles; we are developing technologies to focus decontamination on the

  2. Excimer laser decontamination

    NASA Astrophysics Data System (ADS)

    Sentis, Marc L.; Delaporte, Philippe C.; Marine, Wladimir; Uteza, Olivier P.

    2000-04-01

    The application of excimer laser ablation process to the decontamination of radioactive surfaces is discussed. This technology is very attractive because it allows to efficiently remove the contaminated particles without secondary waste production. To demonstrate the capability of such technology to efficiently decontaminate large area, we studied and developed a prototype which include a XeCl laser, an optical fiber delivery system and an ablated particles collection cell. The main physical processes taking place during UV laser ablation will be explained. The influence of laser wavelength, pulse duration and absorption coefficient of material will be discussed. Special studies have been performed to understand the processes which limit the transmission of high average power excimer laser through optical fiber, and to determine the laser conditions to optimize the value of this transmission. An in-situ spectroscopic analysis of laser ablation plasma allows the real time control of the decontamination. The results obtained for painting or metallic oxides removal from stainless steel surfaces will be presented.

  3. Independent verification of plutonium decontamination on Johnston Atoll (1992--1996)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilson-Nichols, M.J.; Wilson, J.E.; McDowell-Boyer, L.M.

    1998-05-01

    The Field Command, Defense Special Weapons Agency (FCDSWA) (formerly FCDNA) contracted Oak Ridge National Laboratory (ORNL) Environmental Technology Section (ETS) to conduct an independent verification (IV) of the Johnston Atoll (JA) Plutonium Decontamination Project by an interagency agreement with the US Department of Energy in 1992. The main island is contaminated with the transuranic elements plutonium and americium, and soil decontamination activities have been ongoing since 1984. FCDSWA has selected a remedy that employs a system of sorting contaminated particles from the coral/soil matrix, allowing uncontaminated soil to be reused. The objective of IV is to evaluate the effectiveness ofmore » remedial action. The IV contractor`s task is to determine whether the remedial action contractor has effectively reduced contamination to levels within established criteria and whether the supporting documentation describing the remedial action is adequate. ORNL conducted four interrelated tasks from 1992 through 1996 to accomplish the IV mission. This document is a compilation and summary of those activities, in addition to a comprehensive review of the history of the project.« less

  4. Use of Vaporized Hydrogen Peroxide Decontamination during an Outbreak of Multidrug-Resistant Acinetobacter baumannii Infection at a Long-Term Acute Care Hospital

    PubMed Central

    Ray, Amy; Perez, Federico; Beltramini, Amanda M.; Jakubowycz, Marta; Dimick, Patricia; Jacobs, Michael R.; Roman, Kathy; Bonomo, Robert A.; Salata, Robert A.

    2013-01-01

    OBJECTIVES To describe vaporized hydrogen peroxide (VHP) as an adjuvant in the control of multidrug-resistant (MDR) Acinetobacter baumannii infection in a long-term acute care hospital (LTACH) and to describe the risk factors for acquisition of MDR A. baumannii infection in the LTACH population. DESIGN Outbreak investigation, case-control study, and before-after intervention trial. SETTING A 54-bed LTACH affiliated with a tertiary care center in northeastern Ohio. METHODS Investigation of outbreak with clinical and environmental cultures, antimicrobial susceptibility testing, polymerase chain reaction assay of repetitive chromosomal elements to type strains, and case-control study; and intervention consisting of comprehensive infection control measures and VHP environmental decontamination. RESULTS Thirteen patients infected or colonized with MDR A. baumannii were identified from January 2008 through June 2008. By susceptibility testing, 10 (77%) of the 13 isolates were carbapenem-resistant. MDR A. baumannii was found in wound samples, blood, sputum, and urine. Wounds were identified as a risk factor for MDR A. baumannii colonization. Ventilator–associated pneumonia was the most common clinical syndrome caused by the pathogen, and the associated mortality was 14% (2 of the 13 case patients died). MDR A. baumannii was found in 8 of 93 environmental samples, including patient rooms and a wound care cart; environmental and clinical cultures were genetically related. Environmental cultures were negative immediately after VHP decontamination and both 24 hours and 1 week after VHP decontamination. Nosocomial acquisition of the pathogen in the LTACH ceased after VHP intervention. When patients colonized with MDR A. baumannii reoccupied rooms, environmental contamination recurred. CONCLUSION Environmental decontamination using VHP combined with comprehensive infection control measures interrupted nosocomial transmission of MDR A. baumannii in an LTACH. The application of this novel approach to halt the transmission of MDR A. baumannii warrants further investigation. PMID:20973723

  5. Pulsed-plasma gas-discharge inactivation of microbial pathogens in chilled poultry wash water.

    PubMed

    Rowan, N J; Espie, S; Harrower, J; Anderson, J G; Marsili, L; MacGregor, S J

    2007-12-01

    A pulsed-plasma gas-discharge (PPGD) system was developed for the novel decontamination of chilled poultry wash water. Treatment of poultry wash water in the plasma generation chamber for up to 24 s at 4 degrees C reduced Escherichia coli NCTC 9001, Campylobacter jejuni ATCC 33560, Campylobacter coli ATCC 33559, Listeria monocytogenes NCTC 9863, Salmonella enterica serovar Enteritidis ATCC 4931, and S. enterica serovar Typhimurium ATCC 14028 populations to non-detectable levels (< or = 8 log CFU/ml). Although similar PPGD treatments at 4 degrees C also produced significant reductions (> or = 3 log CFU/ml) in recalcitrant B. cereus NCTC 11145 endospore numbers within 30 s, the level of endospore reduction was dependent on the nature of the sparged gas used in the plasma treatments. Scanning electron microscopy revealed that significant damage occurred at the cellular level in PPGD-treated test organisms. This electrotechnology delivers energy in intense ultrashort bursts, generating products such as ozone, UV light, acoustic and shock waves, and pulsed electric fields that have multiple bactericidal properties. This technology offers an exciting complementary or alternative approach for treating raw poultry wash water and for preventing cross-contamination in processing environments.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rick Demmer; John Drake; Ryan James, PhD

    Over the last 50 years, the study of radiological contamination and decontamination has expanded significantly. This paper addresses the mechanisms of radiological contamination that have been reported and then discusses which methods have recently been used during performance testing of several different decontamination technologies. About twenty years ago the Idaho Nuclear Technology Engineering Center (INTEC) at the INL began a search for decontamination processes which could minimize secondary waste. In order to test the effectiveness of these decontamination technologies, a new simulated contamination, termed SIMCON, was developed. SIMCON was designed to replicate the types of contamination found on stainless steel,more » spent fuel processing equipment. Ten years later, the INL began research into methods for simulating urban contamination resulting from a radiological dispersal device (RDD). This work was sponsored by the Defense Advanced Research Projects Agency (DARPA) and included the initial development an aqueous application of contaminant to substrate. Since 2007, research sponsored by the US Environmental Protection Agency (EPA) has advanced that effort and led to the development of a contamination method that simulates particulate fallout from an Improvised Nuclear Device (IND). The IND method diverges from previous efforts to create tenacious contamination by simulating a reproducible “loose” contamination. Examining these different types of contamination (and subsequent decontamination processes), which have included several different radionuclides and substrates, sheds light on contamination processes that occur throughout the nuclear industry and in the urban environment.« less

  7. Comparison of skin decontamination efficacy of commercial decontamination products following exposure to VX on human skin.

    PubMed

    Thors, L; Koch, M; Wigenstam, E; Koch, B; Hägglund, L; Bucht, A

    2017-08-01

    The decontamination efficacy of four commercially available skin decontamination products following exposure to the nerve agent VX was evaluated in vitro utilizing a diffusion cell and dermatomed human skin. The products included were Reactive Skin Decontamination Lotion (RSDL), the Swedish decontamination powder 104 (PS104), the absorbent Fuller's Earth and the aqueous solution alldecontMED. In addition, various decontamination procedures were assessed to further investigate important mechanisms involved in the specific products, e.g. decontamination removal from skin, physical removal by sponge swabbing and activation of degradation mechanisms. The efficacy of each decontamination product was evaluated 5 or 30 min after dermal application of VX (neat or diluted to 20% in water). The RSDL-lotion was superior in reducing the penetration of VX through human skin, both when exposed as neat agent and when diluted to 20% in water. Swabbing with the RSDL-sponge during 2 min revealed decreased efficacy compared to applying the RSDL-lotion directly on the skin for 30 min. Decontamination with Fuller's Earth and alldecontMED significantly reduced the penetration of neat concentration of VX through human skin. PS104-powder was insufficient for decontamination of VX at both time-points, independently of the skin contact time of PS104. The PS104-slurry (a mixture of PS104-powder and water), slightly improved the decontamination efficacy. Comparing the time-points for initiated decontamination revealed less penetrated VX for RSDL and Fuller's Earth when decontamination was initiated after 5 min compared to 30 min post-exposure, while alldecontMED displayed similar efficacy at both time-points. Decontamination by washing with water only resulted in a significant reduction of penetrated VX when washing was performed 5 min after exposure, but not when decontamination was delayed to 30 min post-exposure of neat VX. In conclusion, early initiated decontamination with the RSDL-lotion, containing both absorption and degrading properties, allowed to act on skin for 30 min was superior in preventing VX from penetrating human skin. Adding water during decontamination resulted in increased penetration of neat VX, however, water in the decontaminant removal process did not influence the decontamination efficacy. From our study on commercially available decontaminants, it is recommended that future product developments should include both strong absorbents and efficient nerve agent degrading components. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Joint Doctrine for Operations in Nuclear, Biological, and Chemical (NBC) Environments

    DTIC Science & Technology

    2000-07-11

    groups may have or be able to acquire military, civilian, and dual-use technologies and methods that provide adequate reliability for selective...procedures, and methods . •• Patient decontamination reduces the threat of contamination-related injury to health service support (HSS) personnel and...passing warnings to workers and units throughout their sites. •• Because of the variety of delivery methods for NBC weapons and the limitations of

  9. RE-ENTERING BUILDING FOLLOWING CHEMICAL ATTACK: MEASURING THE EFFECTIVENESS OF SURFACE DECONTAMINATION

    EPA Science Inventory

    Prior to re-entering a building following a chemical attack, decontamination and testing must be conducted to determine whether toxic agents have been eliminated or reduced to safe levels. Building contents must also be decontaminated and tested or destroyed. Recent incidents i...

  10. Experience with chemical system decontamination by the CORD process and electrochemical decontamination of pipe ends

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wille, H.; Bertholdt, H.O.; Operschall, H.

    Efforts to reduce occupational radiation exposure during inspection and repair work in nuclear power plants turns steadily increasing attention to the decontamination of systems and components. Due to the advanced age of nuclear power plants resulting in increasing dose rates, the decontamination of components, or rather of complete systems, or loops to protect operating and inspection personnel becomes demanding. Besides, decontaminating complete primary loops is in many cases less difficult than cleaning large components. Based on experience gained in nuclear power plants, an outline of two different decontamination methods performed recently are given. For the decontamination of complete systems ormore » loops, Kraftwerk Union AG has developed CORD, a low-concentration process. For the decontamination performance of a subsystem, such as the steam generator (SG) channel heads of a pressurized water reactor or the recirculation loops of a boiling water reactor the automated mobile decontamination appliance is used. The electrochemical decontamination process is primarily applicable for the treatment of specially limited surface areas.« less

  11. DECONTAMINATION OF STRUCTURES AND DEBRIS AT SUPERFUND SITES

    EPA Science Inventory

    Two building decontamination technologies were demonstrated and evaluated: a method for in situ degradation of PCB's requiring application of an alkali metal/polyethylene glycolate mixture directly on concrete surfaces; and a shotblasting technique using steel shot to cut away co...

  12. Investigations into the application of a combination of bioventing and biotrickling filter technologies for soil decontamination processes--a transition regime between bioventing and soil vapour extraction.

    PubMed

    Magalhães, S M C; Ferreira Jorge, R M; Castro, P M L

    2009-10-30

    Bioventing has emerged as one of the most cost-effective in situ technologies available to address petroleum light-hydrocarbon spills, one of the most common sources of soil pollution. However, the major drawback associated with this technology is the extended treatment time often required. The present study aimed to illustrate how an intended air-injection bioventing technology can be transformed into a soil vapour extraction effort when the air flow rates are pushed to a stripping mode, thus leading to the treatment of the off-gas resulting from volatilisation. As such, a combination of an air-injection bioventing system and a biotrickling filter was applied for the treatment of contaminated soil, the latter aiming at the treatment of the emissions resulting from the bioventing process. With a moisture content of 10%, soil contaminated with toluene at two different concentrations, namely 2 and 14 mg g soil(-1), were treated successfully using an air-injection bioventing system at a constant air flow rate of ca. 0.13 dm(3) min(-1), which led to the removal of ca. 99% toluene, after a period of ca. 5 days of treatment. A biotrickling filter was simultaneously used to treat the outlet gas emissions, which presented average removal efficiencies of ca. 86%. The proposed combination of biotechnologies proved to be an efficient solution for the decontamination process, when an excessive air flow rate was applied, reducing both the soil contamination and the outlet gas emissions, whilst being able to reduce the treatment time required by bioventing only.

  13. Anthrax Sampling and Decontamination: Technology Trade-Offs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Price, Phillip N.; Hamachi, Kristina; McWilliams, Jennifer

    2008-09-12

    The goal of this project was to answer the following questions concerning response to a future anthrax release (or suspected release) in a building: 1. Based on past experience, what rules of thumb can be determined concerning: (a) the amount of sampling that may be needed to determine the extent of contamination within a given building; (b) what portions of a building should be sampled; (c) the cost per square foot to decontaminate a given type of building using a given method; (d) the time required to prepare for, and perform, decontamination; (e) the effectiveness of a given decontamination methodmore » in a given type of building? 2. Based on past experience, what resources will be spent on evaluating the extent of contamination, performing decontamination, and assessing the effectiveness of the decontamination in abuilding of a given type and size? 3. What are the trade-offs between cost, time, and effectiveness for the various sampling plans, sampling methods, and decontamination methods that have been used in the past?« less

  14. Inactivation of Burkholderia pseudomallei on environmental surfaces using spray-applied, common liquid disinfectants.

    PubMed

    Calfee, M W; Wendling, M

    2015-11-01

    Five commercially available liquid antimicrobials were evaluated for their ability to decontaminate common environmental surface materials, contaminated with Burkholderia pseudomallei, using a spray-based disinfectant delivery procedure. Tests were conducted at both an ambient temperature (c. 20°C) and a lower temperature (c. 12°C) condition. Nonporous materials (glass and aluminium) were more easily decontaminated than porous materials (wood, concrete and carpet). Citric acid (1%) demonstrated poor efficacy in all test conditions. Bleach (pH-adjusted), ethanol (70%), quaternary ammonium and PineSol®, demonstrated high (>6 log10 reduction) efficacies on glass and aluminium at both temperatures, but achieved varying results for wood, carpet and concrete. Temperature had minimal effect on decontamination efficacy during these tests. Much of the antimicrobial efficacy data for pathogenic micro-organisms are generated with testing that utilizes hard nonporous surface materials. These data are not directly translatable for decontaminant selection following an incident whereby complex and porous environmental surfaces are contaminated. This study presents efficacy data for spray-applied antimicrobial liquids, when used to decontaminate common environmental surfaces contaminated with Burkholderia pseudomallei. These data can help responders develop effective remediation strategies following an environmental contamination incident involving B. pseudomallei. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.

  15. The effectiveness of UV-C radiation for facility-wide environmental disinfection to reduce health care-acquired infections.

    PubMed

    Napolitano, Nathanael A; Mahapatra, Tanmay; Tang, Weiming

    2015-12-01

    Health care-acquired infections (HAIs) constitute an increasing threat for patients worldwide. Potential contributors of HAIs include environmental surfaces in health care settings, where ultraviolet-C radiation (UV-C) is commonly used for disinfection. This UV-C intervention-based pilot study was conducted in a hospital setting to identify any change in the incidence of HAIs before and after UV-C intervention, and to determine the effectiveness of UV-C in reducing pathogens. In a hospital in Culver City, CA, during 2012-2013, bactericidal doses of UV-C radiation (254 nm) were delivered through a UV-C-based mobile environmental decontamination unit. The UV-C dosing technology and expertise of the specifically trained personnel were provided together as a dedicated service model by a contracted company. The incidence of HAIs before and after the intervention period were determined and compared. The dedicated service model dramatically reduced HAIs (incidence difference, 1.3/1000 patient-days, a 34.2% reduction). Reductions in the total number and incidence proportions (28.8%) of HAIs were observed after increasing and maintaining the coverage of UV-C treatments. The dedicated service model was found to be effective in decreasing the incidence of HAIs, which could reduce disease morbidity and mortality in hospitalized patients. This model provides a continuously monitored and frequently UV-C-treated patient environment. This approach to UV-C disinfection was associated with a decreased incidence of HAIs. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  16. Comparison of hospital room surface disinfection using a novel ultraviolet germicidal irradiation (UVGI) generator.

    PubMed

    Jelden, Katelyn C; Gibbs, Shawn G; Smith, Philip W; Hewlett, Angela L; Iwen, Peter C; Schmid, Kendra K; Lowe, John J

    2016-09-01

    The estimated 721,800 hospital acquired infections per year in the United States have necessitated development of novel environmental decontamination technologies such as ultraviolet germicidal irradiation (UVGI). This study evaluated the efficacy of a novel, portable UVGI generator (the TORCH, ChlorDiSys Solutions, Inc., Lebanon, NJ) to disinfect surface coupons composed of plastic from a bedrail, stainless steel, chrome-plated light switch cover, and a porcelain tile that were inoculated with methicillin-resistant Staphylococcus aureus (MRSA) or vancomycin-resistant Enterococcus faecalis (VRE). Each surface type was placed at 6 different sites within a hospital room and treated by 10-min ultraviolet-C (UVC) exposures using the TORCH with doses ranging from 0-688 mJ/cm(2) between sites. Organism reductions were compared with untreated surface coupons as controls. Overall, UVGI significantly reduced MRSA by an average of 4.6 log10 (GSD: 1.7 log10, 77% inactivation, p < 0.0001) and VRE by an average of 3.9 log10 (GSD: 1.7 log10, 65% inactivation, p < 0.0001). MRSA on bedrail was reduced significantly (p < 0.0001) less than on other surfaces, while VRE was reduced significantly less on chrome (p = 0.0004) and stainless steel (p = 0.0012) than porcelain tile. Organisms out of direct line of sight of the UVC generator were reduced significantly less (p < 0.0001) than those directly in line of sight. UVGI was found an effective method to inactivate nosocomial pathogens on surfaces evaluated within the hospital environment in direct line of sight of UVGI treatment with variation between organism and surface types.

  17. Comparison of two whole-room ultraviolet irradiation systems for enhanced disinfection of contaminated hospital patient rooms.

    PubMed

    Ali, S; Yui, S; Muzslay, M; Wilson, A P R

    2017-10-01

    Ultraviolet (UV) light decontamination systems are being used increasingly to supplement terminal disinfection of patient rooms. However, efficacy may not be consistent in the presence of soil, especially against Clostridium difficile spores. To demonstrate in-use efficacy of two whole-room UV decontamination systems against three hospital pathogens with and without soil. For each system, six patient rooms were decontaminated with UV irradiation (enhanced disinfection) following manual terminal cleaning. Total aerobic colony counts of surface contamination were determined by spot-sampling 15 environmental sites before and after terminal disinfection and after UV irradiation. Efficacy against biological indicator coupons (stainless-steel discs) was performed for each system using test bacteria (10 6  cfu EMRSA-15 variant A, carbapenemase-producing Klebsiella pneumoniae) or spores (10 5  cfu C. difficile 027), incorporating low soiling [0.03% bovine serum albumin (BSA)], heavy soiling (10% BSA) or synthetic faeces (C. difficile only) placed at five locations in the room. UV disinfection eliminated contamination after terminal cleaning in 8/14 (57%) and 11/14 (79%) sites. Both systems demonstrated 4-5 log 10 reductions in meticillin-resistant Staphylococcus aureus and K. pneumoniae at low soiling. Lower and more variable log 10 reductions were achieved when heavy soiling was present. Between 0.1 and 4.8 log 10 reductions in C. difficile spores were achieved with low but not heavy soil challenge. Terminal disinfection should be performed on all surfaces prior to UV decontamination. In-house validation studies should be considered to ensure optimal positioning in each room layout and sufficient cycle duration to eliminate target pathogens. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  18. Using lytic bacteriophages to eliminate or significantly reduce contamination of food by foodborne bacterial pathogens.

    PubMed

    Sulakvelidze, Alexander

    2013-10-01

    Bacteriophages (also called 'phages') are viruses that kill bacteria. They are arguably the oldest (3 billion years old, by some estimates) and most ubiquitous (total number estimated to be 10(30) -10(32) ) known organisms on Earth. Phages play a key role in maintaining microbial balance in every ecosystem where bacteria exist, and they are part of the normal microflora of all fresh, unprocessed foods. Interest in various practical applications of bacteriophages has been gaining momentum recently, with perhaps the most attention focused on using them to improve food safety. That approach, called 'phage biocontrol', typically includes three main types of applications: (i) using phages to treat domesticated livestock in order to reduce their intestinal colonization with, and shedding of, specific bacterial pathogens; (ii) treatments for decontaminating inanimate surfaces in food-processing facilities and other food establishments, so that foods processed on those surfaces are not cross-contaminated with the targeted pathogens; and (iii) post-harvest treatments involving direct applications of phages onto the harvested foods. This mini-review primarily focuses on the last type of intervention, which has been gaining the most momentum recently. Indeed, the results of recent studies dealing with improving food safety, and several recent regulatory approvals of various commercial phage preparations developed for post-harvest food safety applications, strongly support the idea that lytic phages may provide a safe, environmentally-friendly, and effective approach for significantly reducing contamination of various foods with foodborne bacterial pathogens. However, some important technical and nontechnical problems may need to be addressed before phage biocontrol protocols can become an integral part of routine food safety intervention strategies implemented by food industries in the USA. © 2013 Society of Chemical Industry.

  19. Control of Aeromonas on minimally processed vegetables by decontamination with lactic acid, chlorinated water, or thyme essential oil solution.

    PubMed

    Uyttendaele, M; Neyts, K; Vanderswalmen, H; Notebaert, E; Debevere, J

    2004-02-01

    Aeromonas is an opportunistic pathogen, which, although in low numbers, may be present on minimally processed vegetables. Although the intrinsic and extrinsic factors of minimally processed prepacked vegetable mixes are not inhibitory to the growth of Aeromonas species, multiplication to high numbers during processing and storage of naturally contaminated grated carrots, mixed lettuce, and chopped bell peppers was not observed. Aeromonas was shown to be resistant towards chlorination of water, but was susceptible to 1% and 2% lactic acid and 0.5% and 1.0% thyme essential oil treatment, although the latter provoked adverse sensory properties when applied for decontamination of chopped bell peppers. Integration of a decontamination step with 2% lactic acid in the processing line of grated carrots was shown to have the potential to control the overall microbial quality of the grated carrots and was particularly effective towards Aeromonas.

  20. Firefighter attitudes, norms, beliefs, barriers, and behaviors toward post-fire decontamination processes in an era of increased cancer risk.

    PubMed

    Harrison, Tyler R; Muhamad, Jessica Wendorf; Yang, Fan; Morgan, Susan E; Talavera, Ed; Caban-Martinez, Alberto; Kobetz, Erin

    2018-04-01

    Firefighters are exposed to carcinogens such as volatile organic compounds (VOCs) and polycyclic aromatic hydrocarbons (PAHs) during fires and from their personal protective equipment (PPE). Recent research has shown that decontamination processes can reduce contamination on both gear and skin. While firefighter cultures that honor dirty gear are changing, little is known about current attitudes and behaviors toward decontamination in the fire service. Four hundred eighty-five firefighters from four departments completed surveys about their attitudes, beliefs, perceived norms, barriers, and behaviors toward post-fire decontamination processes. Overall, firefighters reported positive attitudes, beliefs, and perceived norms about decontamination, but showering after a fire was the only decontamination process that occurred regularly, with field decontamination, use of cleansing wipes, routine gear cleaning, and other behaviors all occurring less frequently. Firefighters reported time and concerns over wet gear as barriers to decontamination.

  1. Current and Future Technologies for Microbiological Decontamination of Cereal Grains.

    PubMed

    Los, Agata; Ziuzina, Dana; Bourke, Paula

    2018-06-01

    Cereal grains are the most important staple foods for mankind worldwide. The constantly increasing annual production and yield is matched by demand for cereals, which is expected to increase drastically along with the global population growth. A critical food safety and quality issue is to minimize the microbiological contamination of grains as it affects cereals both quantitatively and qualitatively. Microorganisms present in cereals can affect the safety, quality, and functional properties of grains. Some molds have the potential to produce harmful mycotoxins and pose a serious health risk for consumers. Therefore, it is essential to reduce cereal grain contamination to the minimum to ensure safety both for human and animal consumption. Current production of cereals relies heavily on pesticides input, however, numerous harmful effects on human health and on the environment highlight the need for more sustainable pest management and agricultural methods. This review evaluates microbiological risks, as well as currently used and potential technologies for microbiological decontamination of cereal grains. © 2018 Institute of Food Technologists®.

  2. Rheological changes in irradiated chicken eggs

    NASA Astrophysics Data System (ADS)

    Ferreira, Lúcia F. S.; Del Mastro, Nélida L.

    1998-06-01

    Pathogenic bacteria may cause foodborne illnesses. Humans may introduce pathogens into foods during production, processing, distribution and or preparation. Some of these microorganisms are able to survive conventional preservation treatments. Heat pasteurization, which is a well established and satisfactory means of decontamination/disinfection of liquid foods, cannot efficiently achieve a similar objective for solid foods. Extensive work carried out worldwide has shown that irradiation is efficient in eradicating foodborne pathogens like Salmonella spp. that can contaminate poultry products. In this work Co-60 gamma irradiation was applied to samples of industrial powder white, yolk and whole egg at doses between 0 and 25 kGy. Samples were rehydrated and the viscosity measured in a Brookfield viscosimeter, model DV III at 5, 15 and 25°C. The rheological behaviour among the various kinds of samples were markedly different. Irradiation with doses up to 5 kGy, known to reduced bacterial contamination to non-detectable levels, showed almost no variation of viscosity of irradiated egg white samples. On the other hand, whole or yolk egg samples showed some changes in rheological properties depending on the dose level, showing the predominance of whether polimerization or degradation as a result of the irradiation. Additionally, irradiation of yolk egg powder reduced yolk color as a function of the irradiation exposure implemented. The importance of these results are discussed in terms of possible industrial applications.

  3. Soil removal as a decontamination practice and radiocesium accumulation in tadpoles in rice paddies at Fukushima.

    PubMed

    Sakai, Masaru; Gomi, Takashi; Nunokawa, Masanori; Wakahara, Taeko; Onda, Yuichi

    2014-04-01

    We investigated the biological accumulation of radiocesium in tadpoles [Rana (Pelophylax) porosa porosa] in rice paddies with and without decontamination practice at Fukushima. Radiocesium was accumulated in surface part of soils both in the control and decontaminated paddies one year after decontamination. Mean (134)Cs and (137)Cs concentrations in tadpoles in the control and decontaminated paddies were 3000 and 4500, and 600 and 890 Bq/kg dry weight, respectively. Radiocesium concentrations in surface soil (0-5 cm depth) and tadpoles in the decontaminated paddy were five times smaller than in the control paddy. These results suggest that decontamination practice can reduce radiocesium concentrations in both soil and tadpoles. However, at the decontaminated paddy, radiocesium concentrations in surface soils became 3.8 times greater one year after decontamination, which indicates that monitoring the subsequent movement of radiocesium in rice paddies and surrounding areas is essential for examining contamination propagation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Modeling the impact of the indigenous microbial population on the maximum population density of Salmonella on alfalfa.

    PubMed

    Rijgersberg, Hajo; Franz, Eelco; Nierop Groot, Masja; Tromp, Seth-Oscar

    2013-07-01

    Within a microbial risk assessment framework, modeling the maximum population density (MPD) of a pathogenic microorganism is important but often not considered. This paper describes a model predicting the MPD of Salmonella on alfalfa as a function of the initial contamination level, the total count of the indigenous microbial population, the maximum pathogen growth rate and the maximum population density of the indigenous microbial population. The model is parameterized by experimental data describing growth of Salmonella on sprouting alfalfa seeds at inoculum size, native microbial load and Pseudomonas fluorescens 2-79. The obtained model fits well to the experimental data, with standard errors less than ten percent of the fitted average values. The results show that the MPD of Salmonella is not only dictated by performance characteristics of Salmonella but depends on the characteristics of the indigenous microbial population like total number of cells and its growth rate. The model can improve the predictions of microbiological growth in quantitative microbial risk assessments. Using this model, the effects of preventive measures to reduce pathogenic load and a concurrent effect on the background population can be better evaluated. If competing microorganisms are more sensitive to a particular decontamination method, a pathogenic microorganism may grow faster and reach a higher level. More knowledge regarding the effect of the indigenous microbial population (size, diversity, composition) of food products on pathogen dynamics is needed in order to make adequate predictions of pathogen dynamics on various food products.

  5. Concrete shaver. Innovative technology summary report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1998-12-01

    The US Department of Energy (DOE) is in the process of decontamination and decommissioning (D and D) for many of its nuclear facilities throughout the United States. These facilities must be dismantled and the demolition waste sized into manageable pieces for handling and disposal. The facilities undergoing D and D are typically chemically and/or radiologically contaminated. To facilitate this work, DOE requires a tool capable of removing the surface of radiologically contaminated concrete floors. Operating requirements for the tool include simple and economical operation, the capability of operating in ambient temperatures from 3 C to 40 C (37 F tomore » 104 F), and the ability to be easily decontaminated. The tool also must be safe for workers. The Marcrist Industries Limited concrete shaver is an electrically driven, self-propelled concrete and coating removal system. This technology consists of a 25-cm (10-in.)-wide diamond impregnated shaving drum powered by an electric motor and contains a vacuum port for dust extraction. The concrete shaver is ideal for use on open, flat, floor areas. The shaver may also be used on slightly curved surfaces. This shaver is self-propelled and produces a smooth, even surface with little vibration. The concrete shaver is an attractive alternative to traditional pneumatic scabbling tools, which were considered the baseline in this demonstration. The use of this tool reduces worker fatigue (compared to the baseline) due to lower vibration. The shaver is more than five times faster than the five-piston pneumatic scabbler at removing contamination from concrete. Because of this increased productivity, the shaver is 50% less costly to operate than baseline technologies. The DOE has successfully demonstrated the concrete shaver for decontaminating floors for free-release surveys prior to demolition work.« less

  6. Use of encapsulated bacteriophages to enhance farm to fork food safety.

    PubMed

    Hussain, Malik A; Liu, Huan; Wang, Qi; Zhong, Fang; Guo, Qian; Balamurugan, Sampathkumar

    2017-09-02

    Bacteriophages have been successfully applied to control the growth of pathogens in foods and to reduce the colonization and shedding of pathogens by food animals. They are set to play a dominant role in food safety in the future. However, many food-processing operations and the microenvironments in food animals' guts inactivate phages and reduce their infectivity. Encapsulation technologies have been used successfully to protect phages against extreme environments, and have been shown to preserve their activity and enable their release in targeted environments. A number of encapsulation technologies have shown potential for use with bacteriophages. This review discusses the current state of knowledge about the use of encapsulation technologies with bacteriophages to control pathogens in foods and food animals.

  7. Effect of gamma-irradiation on the occurrence of pathogenic microorganisms and nutritive value of four principal cereal grains.

    PubMed

    Aziz, N H; Souzan, R M; Shahin Azza, A

    2006-12-01

    The effects of (60)Co gamma-photon-irradiation on the natural occurrence of pathogenic microorganisms in four principal cereal grains and on amino acids and vitamins in these cereals were investigated. The total numbers of aerobic bacteria were reduced by three logarithmic decades when grains were given a dose of 10kGy. Coliforms and "coagulase- positive" staphylococci were inhibited by a dose of 1kGy, whereas fungi were inhibited by a dose of 5kGy. The 15kGy dose eliminated viable microorganisms in cereal grains, and about 10-30 colony-forming units of Clostridium sp. per gram of grain survived after this dose. The dose of 10kGy did not cause any measurable destruction of total amino acids. Thiamin was reduced by 22-33% and riboflavin by 10-16% after a dose of 10kGy. Irradiation did not increase the acid values significantly, but did increase the peroxide values, which was not accompanied by the off-odors of cereals. We conclude that the overall dose of 10kGy is very effective for microbial decontamination of cereal grains, and does not adversely affect the nutritional quality of cereal grains.

  8. Lyophilized airborne Clostridium botulinum spores as inocula that intestinally colonize antimicrobially pretreated adult mice.

    PubMed Central

    Sugiyama, H; Prather, J L; Woller, M J

    1986-01-01

    Adult mice, made susceptible to Clostridium botulinum by feedings of metronidazole, were immobilized with an anesthetic and held for 30 min in isolators in which a fine powder of lyophilized pathogen spores was made airborne. Exposed mice were surface decontaminated before being kept for 2 days in holding isolators. Mice were intestinally colonized by the pathogen. Colonization rates were related to spore numbers (10(4) to 10(7) type A or B) seeded into isolators. PMID:3531017

  9. Chemical Decontaminant Testing

    DTIC Science & Technology

    2014-10-20

    make certain that the amine group on the VX is entirely in the freebase form needed for complete extraction into the chloroform. (3) When other...information, including suggestions for reducing this burden, to Department of Defense, Washington Headquarters Services, Directorate for information on ...material effects of decontaminants on fielded military equipment (material effects are defined as hardness). Mechanisms of decontaminating equipment

  10. MRSA prevalence rates detected in a tertiary care hospital in Austria and successful treatment of MRSA positive patients applying a decontamination regime with octenidine.

    PubMed

    Pichler, G; Pux, C; Babeluk, R; Hermann, B; Stoiser, E; De Campo, A; Grisold, A; Zollner-Schwetz, I; Krause, R; Schippinger, W

    2018-01-01

    Methicillin-resistant Staphylococcus aureus (MRSA) decontamination regimens predominantly use chlorhexidine bathing in combination with mupirocin nasal ointment. However, resistances in Staphylococcus aureus strains are increasingly common and there is a need of alternative, safe and feasible protocols. This interventional cohort study performed at the Albert Schweitzer Hospital in Graz, Austria, aimed to (1) determine MRSA prevalence at different body sites and (2) assess the efficacy of the decontamination using octenidine-based leave-on products added to existing robust infection control measures. All inpatients of this tertiary care hospital being treated in geriatric medical wards (GWs) and apallic care units (ACUs) were screened for MRSA and decontamination rates were determined after one, two or three decontamination cycles, respectively. At baseline, MRSA was detected in 25 of the 126 patients screened (19.8%). We found MRSA in 13/126 (10.3%) swabs from nasal vestibules, in 12/126 (9.5%) skin swabs, in 11/51 (21.6%) swabs from PEG-stomata or suprapubic catheters and in 8/13 (61.5%) tracheostomata swabs. A maximum of three 5-day decontamination cycles reduced the number of MRSA positive patients by 68.0%. Excluding non-compliant and deceased patients, decontamination reduced MRSA carriage by 93.3% (n = 15). No adverse events related to the applied decontamination regimen occurred. Exclusive screening of the nose might underreport MRSA prevalence rates. In this study, decontamination with octenidine-based leave-on products was safe and effective in a critical patient population.

  11. Cutaneous challenge with chemical warfare agents in the SKH-1 hairless mouse (II): effects of some currently used skin decontaminants (RSDL and Fuller's earth) against liquid sulphur mustard and VX exposure.

    PubMed

    Taysse, L; Dorandeu, F; Daulon, S; Foquin, A; Perrier, N; Lallement, G; Breton, P

    2011-06-01

    Using the hairless mouse screening model presented in the companion paper(1) the aim of this study was to assess two skin decontaminating systems: Fuller's earth (FE) and Reactive Skin Decontamination Lotion (RSDL) against two extremely toxic chemical warfare agents that represent a special percutaneous hazard, sulphur mustard (SM) and O-ethyl-S-(2[di-isopropylamino]ethyl)methyl-phosphonothioate (VX). Five minutes after being exposed on the back to either 2 µL of neat sulphur mustard or 50 µg.kg(-1) of diluted VX, mice were decontaminated. Both systems were able to reduce blisters 3 days after SM exposure. However, RSDL was found to be more efficient than FE in reducing the necrosis of the epidermis and erosion. In the case of VX exposure, RSDL, whatever the ratio of decontaminant to toxicant used (RSDL 10, 20, 50), was not able to sufficiently prevent the inhibition of plasma cholinesterases taken as a surrogate marker of exposure and toxicity. Only FE reduced significantly the ChE inhibition. Some of these observations are different from our previous results obtained in domestic swine and these changes are thus discussed in the perspective of using SKH-1 hairless mice for the initial in vivo screening of decontaminants.

  12. Technical Improvements to an Absorbing Supergel for Radiological Decontamination in Tropical Environments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kaminski, Michael D.; Mertz, Carol J.; Kivenas, Nadia

    Argonne National Laboratory (Argonne) developed a superabsorbing gel-based process (SuperGel) for the decontamination of cesium from concrete and other porous building materials. Here, we report on results that tested the gel decontamination technology on specific concrete and ceramic formulations from a coastal city in Southeast Asia, which may differ significantly from some U.S. sources. Results are given for the evaluation of americium and cesium sequestering agents that are commercially available at a reasonable cost; the evaluation of a new SuperGel formulation that combines the decontamination properties of cesium and americium; the variation of the contamination concentration to determine the effectsmore » on the decontamination factors with concrete, tile, and brick samples; and pilot-scale testing (0.02–0.09 m2 or 6–12 in. square coupons).« less

  13. Decontamination of Salmonella, Shigella, and Escherichia coli O157:H7 from leafy green vegetables using edible plant extracts.

    PubMed

    Orue, Nydia; García, Santos; Feng, Peter; Heredia, Norma

    2013-02-01

    Fresh cilantro, parsley, and spinach are products that are regularly consumed fresh, but are difficult to decontaminate, as a result, they are common vehicles of transmission of enteropathogenic bacteria. In this study, the efficacy of plant extracts as alternatives for disinfection of cilantro, parsley, and spinach that were artificially contaminated with Salmonella, Escherichia coli O157:H7, and Shigella sonnei was determined. Edible plant extracts obtained using ethanol as the extraction solvent were tested to determine the minimum bactericidal concentration (MBC) and those that exhibited the lowest MBC were selected for further studies. Leaves of fresh greens were washed with sterile water and dried. For seeding, leaves were submerged in suspensions of 2 different concentrations of bacteria (1.5 × 10(8) and 1 × 10(5) ), dried, and then stored at 4 °C until use. To determine the effects of the extracts, inoculated leafy greens were submerged in a container and subjected to treatments with chlorine, Citrol®, or selected plant extracts. Each treatment type was stored at 4 °C for 0, 1, 5, and 7 d, and the bacterial counts were determined. From the 41 plant extracts tested, the extracts from oregano leaves and from the peel and pulp of limes were found to be as effective as chlorine or Citrol® in reducing by > 2 logs, the population of pathogenic bacteria on leafy greens and therefore, may be a natural and edible alternative to chemicals to reduce the risk of Salmonella, E. coli O157:H7 and S. sonnei contamination on leafy vegetables. The antimicrobial efficacy of the extracts of Mexican lime and oregano was clearly demonstrated on cilantro, parsley, and spinach. The extracts of Mexican lime and oregano provide alternatives to chlorine to significantly reduce bacterial pathogens that have been associated with outbreaks from contaminated leafy green vegetables. A simple, low cost, and labor-saving extraction system for production of the extracts was used. © 2013 Institute of Food Technologists®

  14. Public experiences of mass casualty decontamination.

    PubMed

    Carter, Holly; Drury, John; Rubin, G James; Williams, Richard; Amlôt, Richard

    2012-09-01

    In this article, we analyze feedback from simulated casualties who took part in field exercises involving mass decontamination, to gain an understanding of how responder communication can affect people's experiences of and compliance with decontamination. We analyzed questionnaire data gathered from 402 volunteers using the framework approach, to provide an insight into the public's experiences of decontamination and how these experiences are shaped by the actions of emergency responders. Factors that affected casualties' experiences of the decontamination process included the need for greater practical information and better communication from responders, and the need for privacy. Results support previous findings from small-scale incidents that involved decontamination in showing that participants wanted better communication from responders during the process of decontamination, including more practical information, and that the failure of responders to communicate effectively with members of the public led to anxiety about the decontamination process. The similarity between the findings from the exercises described in this article and previous research into real incidents involving decontamination suggests that field exercises provide a useful way to examine the effect of responder communication strategies on the public's experiences of decontamination. Future exercises should examine in more detail the effect of various communication strategies on the public's experiences of decontamination. This will facilitate the development of evidence-based communication strategies intended to reduce anxiety about decontamination and increase compliance among members of the public during real-life incidents that involve mass decontamination.

  15. Use of a human skin in vitro model to investigate the influence of 'every-day' clothing and skin surface decontamination on the percutaneous penetration of organophosphates.

    PubMed

    Moore, C A; Wilkinson, S C; Blain, P G; Dunn, M; Aust, G A; Williams, F M

    2014-08-17

    Organophosphates (OPs) are widely used in agriculture. Many studies have investigated the capability of personal protective equipment (PPE) to reduce chemical exposure; however, investigations into the protective effect of 'every-day' clothing are rare. The purpose of this study was to investigate the protective effect of 'every-day' clothing against dermal exposure and to measure early decontamination of skin following exposure to chlorpyrifos and dichlorvos. Using human skin in vitro, absorption of (14)C-labelled chlorpyrifos (500 ng/cm(2)), was shown to be significantly reduced when applied to clothed skin (cotton shirt), regardless of application vehicle (isopropanol (IPA) or propylene glycol (PG)). The majority of applied dose was retained within the clothing after 4 h exposure. Significant reduction in absorption of chlorpyrifos (in PG) was seen through clothed skin when supplemented with skin decontamination at 4 h, compared with clothed skin decontaminated after 24 h, however, this was not observed with IPA. Absorption of dichlorvos (5 μg/cm(2)) was greater through unclothed skin than chlorpyrifos for all vehicles (IPA, isopropyl myristate (IPM) and PG). Significant reduction in absorption was observed when decontaminating clothed skin at 30 min, compared with decontamination at 24 h (post-exposure) for all vehicles. indicate that 'every-day' clothing is effective at reducing exposure to chemicals in contact with skin. Washing the skin surface immediately following removal of exposed clothing can further reduce exposure, depending on the properties of the chemical and vehicle applied. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  16. Cold plasma rapid decontamination of food contact surfaces contaminated with Salmonella biofilms.

    PubMed

    Niemira, Brendan A; Boyd, Glenn; Sites, Joseph

    2014-05-01

    Cross-contamination of foods from persistent pathogen reservoirs is a known risk factor in processing environments. Industry requires a rapid, waterless, zero-contact, chemical-free method for removing pathogens from food contact surfaces. Cold plasma was tested for its ability to inactivate Salmonella biofilms. A 3-strain Salmonella culture was grown to form adherent biofilms for 24, 48, or 72 h on a test surface (glass slides). These were placed on a conveyor belt and passed at various line speeds to provide exposure times of 5, 10, or 15 s. The test plate was either 5 or 7.5 cm under a plasma jet emitter operating at 1 atm using filtered air as the feed gas. The frequency of high-voltage electricity was varied from 23 to 48 kHz. At the closer spacing (5 cm), cold plasma reduced Salmonella biofilms by up to 1.57 log CFU/mL (5 s), 1.82 log CFU/mL (10 s), and 2.13 log CFU/mL (15 s). Increasing the distance to 7.5 cm generally reduced the efficacy of the 15 s treatment, but had variable effects on the 5 and 10 s treatments. Variation of the high-voltage electricity had a greater effect on 10 and 15 s treatments, particularly at the 7.5 cm spacing. For each combination of time, distance, and frequency, Salmonella biofilms of 24, 48, and 72 h growth responded consistently with each other. The results show that short treatments with cold plasma yielded up to a 2.13 log reduction of a durable form of Salmonella contamination on a model food contact surface. This technology shows promise as a possible tool for rapid disinfection of materials associated with food processing. Pathogens such as Salmonella can form chemical-resistant biofilms, making them difficult to remove from food contact surfaces. A 15 s treatment with cold plasma reduced mature Salmonella biofilms by up to 2.13 log CFU/mL (99.3%). This contact-free, waterless method uses no chemical sanitizers. Cold plasma may therefore have a practical application for conveyor belts, equipment, and other food contact surfaces where a rapid, dry antimicrobial process is required. © 2014 Institute of Food Technologists®

  17. Improvement of Vivarium Biodecontamination through Data-acquisition Systems and Automation.

    PubMed

    Devan, Shakthi Rk; Vasu, Suresh; Mallikarjuna, Yogesha; Ponraj, Ramkumar; Kamath, Gireesh; Poosala, Suresh

    2018-03-01

    Biodecontamination is important for eliminating pathogens at research animal facilities, thereby preventing contamination within barrier systems. We enhanced our facility's standard biodecontamination method to replace the traditional foggers, and the new system was used effectively after creating bypass ducts in HVAC units so that individual rooms could be isolated. The entire system was controlled by inhouse-developed supervisory control and data-acquisition software that supported multiple cycles of decontamination by equipment, which had different decontamination capacities, operated in parallel, and used different agents, including H2O2 vapor and ClO2 gas. The process was validated according to facility mapping, and effectiveness was assessed by using biologic (Geobacillus stearothermophilus) and chemical indicator strips, which were positioned before decontamination, and by sampling contact plates after the completion of each cycle. The results of biologic indicators showed 6-log reduction in microbial counts after successful decontamination cycles for both agents and found to be compatible with clean-room panels including commonly used materials in vivarium such as racks, cages, trolleys, cage changing stations, biosafety cabinets, refrigerators and other equipment in both procedure and animal rooms. In conclusion, the automated process enabled users to perform effective decontamination through multiple cycles with realtime documentation and provided additional capability to deal with potential outbreaks. Enabling software integration of automation improved quality-control systems in our vivarium.

  18. The potential for use of steam at atmospheric pressure to decontaminate or sterilize parenteral filling lines incorporating barrier isolation technology.

    PubMed

    Lysfjord, J P; Haas, P J; Melgaard, H L; Pflug, I J

    1995-01-01

    Barrier isolators that enclose aseptic filling equipment are being proposed as a means of: (1) assisting in achieving a 10(-6) sterility assurance level (SAL) in the filling area and (2) minimizing the clean environment required in the manufacturing area. The need for operator and maintenance access to the interior of the barrier isolators presents difficulties in achieving the above goals. Several methods are available for reducing the microbial level inside the isolation barrier. If the objective is the decontamination of all surfaces inside the enclosure, saturated steam at atmospheric pressure can be used. If the objective is to sterilize the inside of the enclosure, saturated steam at atmospheric pressure with added H2O2 can be used. Test data and practical interface considerations relative to various methodologies will be reviewed.

  19. Decontamination work in the area surrounding Fukushima Dai-ichi Nuclear Power Plant: another occupational health challenge of the nuclear disaster.

    PubMed

    Wada, Koji; Yoshikawa, Toru; Murata, Masaru

    2012-01-01

    This article describes occupational health measures for workers involved in decontamination of radioactive material discharged around Fukushima Dai-ichi Nuclear Power Plant after the explosions in 2011. Decontamination is performed by removing radioactive particles (mainly cesium) from surfaces of soil, grass and trees, and buildings. Measurement of radiation doses is necessary to reduce exposure, and to determine whether workers can work below dose limits. Protective equipment for decontamination is determined based on the concentration of radiation in contaminated soil and the exposure to dust. Health examinations by physicians are mandated for decontamination workers upon hiring and every 6 months. While there is no possibility of acute radiation injury from decontamination, workers may be anxious about the unclear effects of chronic low level radiation exposure on health. Measures to protect the decontamination workers are the top priority.

  20. Pathogen inactivation techniques.

    PubMed

    Pelletier, J P R; Transue, S; Snyder, E L

    2006-01-01

    The desire to rid the blood supply of pathogens of all types has led to the development of many technologies aimed at the same goal--eradication of the pathogen(s) without harming the blood cells or generating toxic chemical agents. This is a very ambitious goal, and one that has yet to be achieved. One approach is to shun the 'one size fits all' concept and to target pathogen-reduction agents at the Individual component types. This permits the development of technologies that might be compatible with, for example, plasma products but that would be cytocidal and thus incompatible with platelet concentrates or red blood cell units. The technologies to be discussed include solvent detergent and methylene blue treatments--designed to inactivate plasma components and derivatives; psoralens (S-59--amotosalen) designed to pathogen-reduce units of platelets; and two products aimed at red blood cells, S-303 (a Frale--frangible anchor-linker effector compound) and Inactine (a binary ethyleneimine). A final pathogen-reduction material that might actually allow one material to inactivate all three blood components--riboflavin (vitamin B2)--is also under development. The sites of action of the amotosalen (S-59), the S-303 Frale, Inactine, and riboflavin are all localized in the nucleic acid part of the pathogen. Solvent detergent materials act by dissolving the plasma envelope, thus compromising the integrity of the pathogen membrane and rendering it non-infectious. By disrupting the pathogen's ability to replicate or survive, its infectivity is removed. The degree to which bacteria and viruses are affected by a particular pathogen-reducing technology relates to its Gram-positive or Gram-negative status, to the sporulation characteristics for bacteria, and the presence of lipid or protein envelopes for viruses. Concerns related to photoproducts and other breakdown products of these technologies remain, and the toxicology of pathogen-reduction treatments is a major ongoing area of investigation. Clearly, regulatory agencies have a major role to play in the evaluation of these new technologies. This chapter will cover the several types of pathogen-reduction systems, mechanisms of action, the inactivation efficacy for specific types of pathogens, toxicology of the various systems and the published research and clinical trial data supporting their potential usefulness. Due to the nature of the field, pathogen reduction is a work in progress and this review should be considered as a snapshot in time rather than a clear picture of what the future will bring.

  1. Evaluation of standard and alternative methods for the decontamination of VX and HD in chemical agent disposal facilities. Final report, February 1992-February 1993

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hovanec, J.W.; Szafraniec, L.L.; Albizo, J.M.

    1993-04-01

    Standard decontaminant formulations, aqueous sodium hydroxide and aqueous sodium hypochlorite, were providing slow and incomplete results when used to decontaminate certain operating facilities at the Johnston Atoll Chemical Agent Disposal System and the Chemical Agent Disposal System (Utah). A study was undertaken to define the capabilities and limitations of using concentrated sodium hydroxide to decontaminate VX, the effect of adding hydrogen peroxide to the sodium hydroxide for the decontamination of VX, the efficacy of aqueous oxone for the decontamination of VX, and the efficacy of oxone in a water/1-methyl-2-pyrrolidinone (MP) mixture for the decontamination of HD. Using aqueous sodium hydroxidemore » alone was not desirable since the formation of toxic EA2192 could not be averted. However, the addition of hydrogen peroxide resulted in effective VX decontamination without EA2192 formation. Aqueous oxone was also found to be effective for both VX and HD. The incorporation of MP did little to improve HD dissolution and reacted with the oxone to reduce the effective usable life of the decontamination solution. Thus, the use of MP in HD decontamination was not recommended.« less

  2. Decontamination Efficacy and Skin Toxicity of Two Decontaminants against Bacillus anthracis

    PubMed Central

    Stratilo, Chad W.; Crichton, Melissa K. F.; Sawyer, Thomas W.

    2015-01-01

    Decontamination of bacterial endospores such as Bacillus anthracis has traditionally required the use of harsh or caustic chemicals. The aim of this study was to evaluate the efficacy of a chlorine dioxide decontaminant in killing Bacillus anthracis spores in solution and on a human skin simulant (porcine cadaver skin), compared to that of commonly used sodium hypochlorite or soapy water decontamination procedures. In addition, the relative toxicities of these decontaminants were compared in human skin keratinocyte primary cultures. The chlorine dioxide decontaminant was similarly effective to sodium hypochlorite in reducing spore numbers of Bacillus anthracis Ames in liquid suspension after a 10 minute exposure. After five minutes, the chlorine dioxide product was significantly more efficacious. Decontamination of isolated swine skin contaminated with Bacillus anthracis Sterne with the chlorine dioxide product resulted in no viable spores sampled. The toxicity of the chlorine dioxide decontaminant was up to two orders of magnitude less than that of sodium hypochlorite in human skin keratinocyte cultures. In summary, the chlorine dioxide based decontaminant efficiently killed Bacillus anthracis spores in liquid suspension, as well as on isolated swine skin, and was less toxic than sodium hypochlorite in cultures of human skin keratinocytes. PMID:26394165

  3. Eradication of Methicillin-Resistant Staphylococcus aureus and of Enterobacteriaceae Expressing Extended-Spectrum Beta-Lactamases on a Model Pig Farm

    PubMed Central

    Kellner, Sophia Ricarda; Schulze-Geisthoevel, Sophia Veronika; Hack, Sylvia; Engelhart, Steffen; Bodenstein, Isabel; Al-Sabti, Nahed; Reif, Marion; Fimmers, Rolf; Körber-Irrgang, Barbara; Harlizius, Jürgen; Hoerauf, Achim; Exner, Martin; Bierbaum, Gabriele; Petersen, Brigitte

    2015-01-01

    Colonization of livestock with bacteria resistant to antibiotics is considered a risk for the entry of drug-resistant pathogens into the food chain. For this reason, there is a need for novel concepts to address the eradication of drug-resistant commensals on farms. In the present report, we evaluated the decontamination measures taken on a farm contaminated with methicillin-resistant Staphylococcus aureus (MRSA) and Enterobacteriaceae expressing extended-spectrum β-lactamases (ESBL-E). The decontamination process preceded the conversion from piglet breeding to gilt production. Microbiological surveillance showed that the decontamination measures eliminated the MRSA and ESBL-E strains that were detected on the farm before the complete removal of pigs, cleaning and disinfection of the stable, and construction of an additional stable meeting high-quality standards. After pig production was restarted, ESBL-E remained undetectable over 12 months, but MRSA was recovered from pigs and the environment within the first 2 days. However, spa (Staphylococcus aureus protein A gene) typing revealed acquisition of an MRSA strain (type t034) that had not been detected before decontamination. Interestingly, we observed that a farmworker who had been colonized with the prior MRSA strain (t2011) acquired the new strain (t034) after 2 months. In summary, this report demonstrates that decontamination protocols similar to those used here can lead to successful elimination of contaminating MRSA and ESBL-E in pigs and the stable environment. Nevertheless, decontamination protocols do not prevent the acquisition of new MRSA strains. PMID:26341200

  4. Eradication of methicillin-resistant Staphylococcus aureus and of Enterobacteriaceae expressing extended-spectrum beta-lactamases on a model pig farm.

    PubMed

    Schmithausen, Ricarda Maria; Kellner, Sophia Ricarda; Schulze-Geisthoevel, Sophia Veronika; Hack, Sylvia; Engelhart, Steffen; Bodenstein, Isabel; Al-Sabti, Nahed; Reif, Marion; Fimmers, Rolf; Körber-Irrgang, Barbara; Harlizius, Jürgen; Hoerauf, Achim; Exner, Martin; Bierbaum, Gabriele; Petersen, Brigitte; Bekeredjian-Ding, Isabelle

    2015-11-01

    Colonization of livestock with bacteria resistant to antibiotics is considered a risk for the entry of drug-resistant pathogens into the food chain. For this reason, there is a need for novel concepts to address the eradication of drug-resistant commensals on farms. In the present report, we evaluated the decontamination measures taken on a farm contaminated with methicillin-resistant Staphylococcus aureus (MRSA) and Enterobacteriaceae expressing extended-spectrum β-lactamases (ESBL-E). The decontamination process preceded the conversion from piglet breeding to gilt production. Microbiological surveillance showed that the decontamination measures eliminated the MRSA and ESBL-E strains that were detected on the farm before the complete removal of pigs, cleaning and disinfection of the stable, and construction of an additional stable meeting high-quality standards. After pig production was restarted, ESBL-E remained undetectable over 12 months, but MRSA was recovered from pigs and the environment within the first 2 days. However, spa (Staphylococcus aureus protein A gene) typing revealed acquisition of an MRSA strain (type t034) that had not been detected before decontamination. Interestingly, we observed that a farmworker who had been colonized with the prior MRSA strain (t2011) acquired the new strain (t034) after 2 months. In summary, this report demonstrates that decontamination protocols similar to those used here can lead to successful elimination of contaminating MRSA and ESBL-E in pigs and the stable environment. Nevertheless, decontamination protocols do not prevent the acquisition of new MRSA strains. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  5. Testing large volume water treatment and crude oil ...

    EPA Pesticide Factsheets

    Report EPA’s Homeland Security Research Program (HSRP) partnered with the Idaho National Laboratory (INL) to build the Water Security Test Bed (WSTB) at the INL test site outside of Idaho Falls, Idaho. The WSTB was built using an 8-inch (20 cm) diameter cement-mortar lined drinking water pipe that was previously taken out of service. The pipe was exhumed from the INL grounds and oriented in the shape of a small drinking water distribution system. Effluent from the pipe is captured in a lagoon. The WSTB can support drinking water distribution system research on a variety of drinking water treatment topics including biofilms, water quality, sensors, and homeland security related contaminants. Because the WSTB is constructed of real drinking water distribution system pipes, research can be conducted under conditions similar to those in a real drinking water system. In 2014, WSTB pipe was experimentally contaminated with Bacillus globigii spores, a non-pathogenic surrogate for the pathogenic B. anthracis, and then decontaminated using chlorine dioxide. In 2015, the WSTB was used to perform the following experiments: • Four mobile disinfection technologies were tested for their ability to disinfect large volumes of biologically contaminated “dirty” water from the WSTB. B. globigii spores acted as the biological contaminant. The four technologies evaluated included: (1) Hayward Saline C™ 6.0 Chlorination System, (2) Advanced Oxidation Process (A

  6. Development of a Complimentary Low Temperature Decontamination Technique for Spacecraft Materials

    NASA Astrophysics Data System (ADS)

    Pottage, Thomas; Bennett, Allan; Walker, James; Fowler, Chantal; Weber, Christina; Rohr, Thomas; Kminek, Gerhard

    Dry heat microbial reduction (DHMR) is one of the current processes used to ensure that the microbial burden of a spacecraft lander meets the predetermined levels set out within the COSPAR policy regarding planetary protection. DHMR involves heating the craft or compo-nents to approximately 110-125C for over 6-30hrs, and was previously used to decontaminate the entire Viking lander spacecraft and parts of almost all other spacecrafts sent to Mars after-wards. This process, whilst proving effective and reproducible is not compatible with the some highly sensitive sensor and electronic components of a modern spacecraft. For these components an alternative method for low temperature decontamination needs to be identified. The Health Protection Agency, UK, investigated three gaseous decontamination technologies in a project funded by European Space Agency. These technologies consisted of two hydrogen peroxide technologies (Vapour Hydrogen Peroxide, Steris Inc. and Hydrogen Peroxide Vapour, Bioquell Ltd.) and one chlorine dioxide (ClorDiSys) system. The technologies were chosen after a comprehensive literature study identified them as the most suitable technologies for the decontamination process. An environmental chamber (20m3 ) was used as the test chamber to expose two commercially available biological indicators, three naturally occurring organisms chosen by ESA and a range of spacecraft materials to each of the technologies. The commercial biological indicators, Bacil-lus atrophaeus and Geobacillus sterothermophilus, were exposed to 3 varying concentrations of each of the technologies in order to attempt to achieve a 6-log reduction in recoverable organ-isms. After these results were obtained the most efficacious cycle was chosen for each technology and the naturally occurring organisms and materials to be tested were exposed to three cy-cles. Whilst the microbial enumeration was completed at the HPA, material compatibility was undertaken at ESTEC and residue analysis at the Rutherford Appleton Laboratories, UK. The results demonstrate that a concentration of approximately 1.1mg/l of hydrogen peroxide injected into the test chamber (35o C) is adequate to demonstrate a 6-log reduction in biological organism recovery for all of the 5 organisms tested over a 20 min period using the Steris generator. The final phase of the work is currently underway and will be incorporated into the final presentation.

  7. Salmonella and Escherichia coli O157:H7 Inactivation, Color, and Bioactive Compounds Enhancement on Raspberries during Frozen Storage after Decontamination Using New Formula Sanitizer Washing or Pulsed Light.

    PubMed

    Xu, Wenqing; Chen, Haiqiang; Wu, Changqing

    2016-07-01

    Berries are normally washed before they are frozen. Washing with sanitizer and treatment with pulsed light (PL) were studied for their effectiveness to inactivate foodborne pathogens on raspberries during frozen storage, while maintaining or enhancing major quality parameters. Raspberries were inoculated with Salmonella or Escherichia coli O157:H7 and then underwent a washing treatment with citric acid plus sodium dodecyl sulfate (CA+SDS) or citric acid plus thymol (CA+THY) or treatment with PL (dry PL, water-assisted [wet] PL, and PL-SDS). Pathogen survival was determined immediately after treatments and during frozen storage at -20°C for 3 months. Washing with CA+SDS or CA+THY significantly reduced Salmonella (by 3.6 and 3.2 log CFU/g, respectively) and E. coli O157:H7 (by 4.1 and 3.7 log CFU/g, respectively). At the end of storage, washing with CA+SDS reduced Salmonella to 0.6 log CFU/g and E. coli O157:H7 to 0.5 log CFU/g; washing with CA+THY reduced Salmonella to 0.9 log CFU/g and E. coli O157:H7 to 0.5 log CFU/g. PL-SDS showed decontamination efficacy on raspberries, with 0.7 log CFU/g Salmonella and 0.9 log CFU/g E. coli O157:H7 surviving at the end of storage; in comparison, in the control, 1.6 log CFU/g Salmonella and 1.5 log CFU/g E. coli O157:H7 survived. Pathogen survival in raspberries that had been washed or treated with PL-SDS was significantly lower than in untreated raspberries. Major quality parameters, including color, total phenolic content, total anthocyanin content, total bacterial count, and total yeast and mold counts, were evaluated on raspberries immediately after treatments and during frozen storage. Redness increased in PL-treated raspberries. At the end of storage, PL-treated raspberries had significantly higher total phenolic content and total anthocyanin content compared with control samples. Washing with sanitizers and treatment with PL decreased the total bacterial count and total yeast and mold counts on raspberries and maintained the low counts. Our findings suggest that washing with a sanitizer or treatment with PL could be used to process frozen raspberries for enhanced food safety and quality.

  8. Microbiological Burden on the Surfaces of Explorer XXXIII Spacecraft1

    PubMed Central

    Powers, Edmund M.

    1967-01-01

    The Explorer XXXIII Spacecraft (Anchored Interplanetary Monitoring Platform, or AIMP) was decontaminated to prevent gross contamination of the moon with terrestrial microorganisms. Assay of the total spacecraft surface before and after decontamination showed that the decontamination procedure reduced the viable microbiological burden from 1.40 × 106 to 3.60 × 104. However, assembly of parts which were not decontaminated for engineering reasons or were not assembled under cleanroom conditions increased the viable microbial burden at the time of launch to 2.62 × 105. Images Fig. 2 PMID:6053173

  9. Rad-Release

    ScienceCinema

    None

    2017-12-09

    The R&D 100 Award winning Rad-Release Chemical Decontamination Technology is a highly effective (up to 99% removal rate), affordable, patented chemical-foam-clay decontamination process tailored to specific radiological and metal contaminants, which is applicable to a wide variety of substrates. For more information about this project, visit http://www.inl.gov/rd100/2011/rad-release/

  10. Decontamination Efficacy of Three Commercial Off-the-Shelf Sporicidal Agents on Medium-Sized Panels Contaminated with Surrogates of Bacillus anthracis

    DTIC Science & Technology

    2012-04-01

    chlorine dioxide (CD) or vapor hydrogen peroxide ( VHP ). A wide-area release and contamination of building exteriors and the outdoors would likely...from the panels. Depending on the surface composition and the decontamination technology tested, viable spore recovery from the panels varied after

  11. SUPERFUND TREATABILITY CLEARINGHOUSE: TECHNOLOGY DEMONSTRATION OF A THERMAL DESORPTION/UV PHOTOLYSIS PROCESS FOR DECONTAMINATING SOILS CONTAINING HERBICIDE ORANGE

    EPA Science Inventory

    This treatability study report presents the results of laboratory and field tests on the effectiveness of a new decontamination process for soils containing 2,4-D/2,4,5-T and traces of dioxin. The process employs three operations, thermal desorption, condensation and absorp...

  12. PYROCHEMICAL DECONTAMINATION METHOD FOR REACTOR FUEL

    DOEpatents

    Buyers, A.G.

    1959-06-30

    A pyro-chemical method is presented for decontaminating neutron irradiated uranium and separating plutonium therefrom by contact in the molten state with a metal chloride salt. Uranium trichloride and uranium tetrachloride either alone or in admixture with alkaline metal and alkaline eanth metal fluorides under specified temperature and specified phase ratio conditions extract substantially all of the uranium from the irradiated uranium fuel together with certain fission products. The phases are then separated leaving purified uranium metal. The uranium and plutonium in the salt phase can be reduced to forin a highly decontaminated uraniumplutonium alloy. The present method possesses advantages for economically decontaminating irradiated nuclear fuel elements since irradiated fuel may be proccessed immediately after withdrawal from the reactor and the uranium need not be dissolved and later reduced to the metallic form. Accordingly, the uranium may be economically refabricated and reinserted into the reactor.

  13. Innovative technology conserves resources and generates savings: a case study from the Sunnybrook Regional Processing Centre.

    PubMed

    Karim, Abdool Z

    2009-01-01

    The regional processing centre at Sunnybrook Health Sciences Centre recently faced the substantial challenge of increasing cleaning capacity to meet the current workload and anticipated future demand without increasing its operating budget. The solution, upgrading its cleaning and decontamination system to a highly automated system, met both objectives. An analysis of the impact of the change found that the new system provided additional benefits, including improved productivity and cleaning quality; decreased costs; reduced water, electricity and chemical use; improved worker safety and morale; and decreased overtime. Investing in innovative technology improved key departmental outcomes while meeting institutional environmental and cost savings objectives.

  14. Roles of sunlight and natural ventilation for controlling infection: historical and current perspectives.

    PubMed

    Hobday, R A; Dancer, S J

    2013-08-01

    Infections caught in buildings are a major global cause of sickness and mortality. Understanding how infections spread is pivotal to public health yet current knowledge of indoor transmission remains poor. To review the roles of natural ventilation and sunlight for controlling infection within healthcare environments. Comprehensive literature search was performed, using electronic and library databases to retrieve English language papers combining infection; risk; pathogen; and mention of ventilation; fresh air; and sunlight. Foreign language articles with English translation were included, with no limit imposed on publication date. In the past, hospitals were designed with south-facing glazing, cross-ventilation and high ceilings because fresh air and sunlight were thought to reduce infection risk. Historical and recent studies suggest that natural ventilation offers protection from transmission of airborne pathogens. Particle size, dispersal characteristics and transmission risk require more work to justify infection control practices concerning airborne pathogens. Sunlight boosts resistance to infection, with older studies suggesting potential roles for surface decontamination. Current knowledge of indoor transmission of pathogens is inadequate, partly due to lack of agreed definitions for particle types and mechanisms of spread. There is recent evidence to support historical data on the effects of natural ventilation but virtually none for sunlight. Modern practice of designing healthcare buildings for comfort favours pathogen persistence. As the number of effective antimicrobial agents declines, further work is required to clarify absolute risks from airborne pathogens along with any potential benefits from additional fresh air and sunlight. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  15. RSDL decontamination of human skin contaminated with the nerve agent VX.

    PubMed

    Thors, L; Lindberg, S; Johansson, S; Koch, B; Koch, M; Hägglund, L; Bucht, A

    2017-03-05

    Dermal exposure to low volatile organophosphorus compounds (OPC) may lead to penetration through the skin and uptake in the blood circulation. Skin decontamination of toxic OPCs, such as pesticides and chemical warfare nerve agents, might therefore be crucial for mitigating the systemic toxicity following dermal exposure. Reactive skin decontamination lotion (RSDL) has been shown to reduce toxic effects in animals dermally exposed to the nerve agent VX. In the present study, an in vitro flow-through diffusion cell was utilized to evaluate the efficacy of RSDL for decontamination of VX exposed to human epidermis. In particular, the impact of timing in the initiation of decontamination and agent dilution in water was studied. The impact of the lipophilic properties of VX in the RSDL decontamination was additionally addressed by comparing chemical degradation in RSDL and decontamination efficacy between the VX and the hydrophilic OPC triethyl phosphonoacetate (TEPA). The epidermal membrane was exposed to 20, 75 or 90% OPC diluted in deionized water and the decontamination was initiated 5, 10, 30, 60 or 120min post-exposure. Early decontamination of VX with RSDL, initiated 5-10min after skin exposure, was very effective. Delayed decontamination initiated 30-60min post-exposure was less effective but still the amount of penetrated agent was significantly reduced, while further delayed start of decontamination to 120min resulted in very low efficacy. Comparing RSDL decontamination of VX with that of TEPA showed that the decontamination efficacy at high agent concentrations was higher for VX. The degradation mechanism of VX and TEPA during decontamination was dissected by 31 P NMR spectroscopy of the OPCs following reactions with RSDL and its three nucleophile components. The degradation rate was clearly associated with the high pH of the specific solution investigated; i.e. increased pH resulted in a more rapid degradation. In addition, the solubility of the OPC in RSDL also influenced the degradation rate since the degradation of VX was significantly faster when the NMR analysis was performed in the organic solvent acetonitrile compared to water. In conclusion, we have applied the in vitro flow-through diffusion cell for evaluation of skin decontamination procedures of human epidermis exposed to OPCs. It was demonstrated that early decontamination is crucial for efficient mitigation of epidermal penetration of VX and that almost complete removal of the nerve agent from the skin surface is possible. Our data also indicate that the pH of RSDL together with the solubility of OPC in RSDL are of primary importance for the decontamination efficacy. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Chemical, biological, radiological, and nuclear decontamination: Recent trends and future perspective

    PubMed Central

    Kumar, Vinod; Goel, Rajeev; Chawla, Raman; Silambarasan, M.; Sharma, Rakesh Kumar

    2010-01-01

    Chemical, biological, radiological, and nuclear (CBRN) decontamination is the removal of CBRN material from equipment or humans. The objective of the decontamination is to reduce radiation burden, salvage equipment, and materials, remove loose CBRN contaminants, and fix the remaining in place in preparation for protective storage or permanent disposal work activities. Decontamination may be carried out using chemical, electrochemical, and mechanical means. Like materials, humans may also be contaminated with CBRN contamination. Changes in cellular function can occur at lower radiation doses and exposure to chemicals. At high dose, cell death may take place. Therefore, decontamination of humans at the time of emergency while generating bare minimum waste is an enormous task requiring dedication of large number of personnel and large amount of time. General principles of CBRN decontamination are discussed in this review with emphasis on radiodecontamination. PMID:21829318

  17. Decontamination of dental implant surface in peri-implantitis treatment: A literature review

    PubMed Central

    Buitrago-Vera, Pedro; Solá-Ruiz, María F.; Ferrer-García, Juan C.

    2013-01-01

    Etiological treatment of peri-implantitis aims to reduce the bacterial load within the peri-implant pocket and decontaminate the implant surface in order to promote osseointegration. The aim of this literature review was to evaluate the efficacy of different methods of implant surface decontamination. A search was conducted using the PubMed (Medline) database, which identified 36 articles including in vivo and in vitro studies, and reviews of different decontamination systems (chemical, mechanical, laser and photodynamic therapies). There is sufficient consensus that, for the treatment of peri-implant infections, the mechanical removal of biofilm from the implant surface should be supplemented by chemical decontamination with surgical access. However, more long-term research is needed to confirm this and to establish treatment protocols responding to different implant characterics. Key words:Peri-implantitis, treatment, decontamination, implant surface, laser. PMID:23986023

  18. Innovative approach to reduction of waste streams for cutting operations in remote environments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Skibo, A.

    SRNL proposes to develop and demonstrate an approach using the SRNL rotary microfilter (RMF) technology for reducing waste streams in remote cutting operations during decontamination operations. SRNL offers to collaborate with Tokyo Electric Power Company (TEPCO) in evaluation, testing, and utilization of SRNL’s radiation-hardened rotary microfilter in the deactivation and decommissioning (D&D) operations of the Fukushima Daiichi Nuclear Power Station (NPS). Refinement of the scope and associated costs will be conducted in consultation with TEPCO.

  19. Title: Efficacy of chlorine dioxide gas to decontaminate fresh produce used for in-store and vendor juicing operations

    USDA-ARS?s Scientific Manuscript database

    Introduction: Unpasteurized juices are increasingly popular as consumers aim to find convenient, healthy options. Contamination of produce with pathogens such as Salmonella, Escherichia coli O157:H7, and Listeria monocytogenes poses a risk. In-store treatment of small batches of mixed types of fresh...

  20. Radiosensitization of Aspergillus niger and Penicillium chrysogenum using basil essential oil and ionizing radiation for food decontamination.

    USDA-ARS?s Scientific Manuscript database

    The Minimum Inhibitory Concentration (MIC) of basil oil, was determined for two pathogenic fungi of rice, Aspergillus niger and Penicillium chrysogenum. The antifungal activity of the basil oil in combination with ionising radiation was then investigated to determine if basil oil caused radiosensit...

  1. The incidence and microbial spectrum of ventilator-associated pneumonia after tracheotomy in a selective decontamination of the digestive tract-setting.

    PubMed

    Veelo, Denise P; Bulut, Tomas; Dongelmans, Dave A; Korevaar, Johanna C; Spronk, Peter E; Schultz, Marcus J

    2008-01-01

    Tracheotomy is considered to be an independent risk factor for ventilator-associated pneumonia (VAP). Antimicrobial prophylaxis, in particular with coverage of Pseudomonas aeruginosa, is presently advocated. Selective decontamination of the digestive tract (SDD) aims to prevent VAP in critically ill patients, including those after tracheotomy. We determined the incidence and microbial spectrum of VAP after tracheotomy in a SDD-setting. Retrospective analysis of 231 tracheotomized patients during a 2-year period. Thirteen patients (5.6%) developed VAP. The median [IQR] day of onset was 8.0 [3.0-10.5] days after tracheotomy. The most predominant causative pathogen was Methicillin-sensitive Staphylococcus aureus (MSSA). Timing of tracheotomy was not different between patients developing VAP and those who did not. The type of tracheotomy (percutaneous or surgical, 84.6% versus 15.4%) had no significant influence on the incidence of VAP. The incidence of VAP after tracheotomy in a SDD-setting is low, with MSSA as the predominant causative pathogen. Accordingly, if antimicrobial prophylaxis is considered, it may be advisable to cover MSSA in an SDD-setting.

  2. Task 21 - Development of Systems Engineering Applications for Decontamination and Decommissioning Activities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Erickson, T.A.

    1998-11-01

    The objectives of this task are to: Develop a model (paper) to estimate the cost and waste generation of cleanup within the Environmental Management (EM) complex; Identify technologies applicable to decontamination and decommissioning (D and D) operations within the EM complex; Develop a database of facility information as linked to project baseline summaries (PBSs). The above objectives are carried out through the following four subtasks: Subtask 1--D and D Model Development, Subtask 2--Technology List; Subtask 3--Facility Database, and Subtask 4--Incorporation into a User Model.

  3. Decontamination of sludge by the METIX-AC process. Part II: effects on maize growth and bioaccumulation of metals.

    PubMed

    Barraoui, Driss; Labrecque, Michel; Blais, Jean-François

    2008-03-01

    Given the fact that, according to our knowledge, no study has compared the agro-environmental use of decontaminated with non-decontaminated sludge, a greenhouse experiment was carried out to test the growth of maize (Zea mays L., G-4011 Hybrid) and bioaccumulation of metals in the presence of four different sludges (MUC, QUC, BEC and DAI), before and after their decontamination by a novel process (METIX-AC). Data showed that decontaminated sludge ameliorated plant growth and biomass production, and decreased bioaccumulation of metals, more than control soil, inorganic chemical fertilization, or conventional non-decontaminated sludge. Since chemicals used by the METIX-AC process contained S and Fe, decontaminated sludge introduced large amounts of these elements, while the overall presence of metals was reduced. Often, sludge dose also affected maize growth and bioaccumulation of metals. Overall, no toxicity to plants was noticed and bioaccumulation and transfer of many metals remained below the limits reported in the literature.

  4. A New Proof of Concept in Bacterial Reduction: Antimicrobial Action of Violet-Blue Light (405 nm) in Ex Vivo Stored Plasma

    PubMed Central

    Maclean, Michelle; Anderson, John G.; MacGregor, Scott J.; White, Tracy

    2016-01-01

    Bacterial contamination of injectable stored biological fluids such as blood plasma and platelet concentrates preserved in plasma at room temperature is a major health risk. Current pathogen reduction technologies (PRT) rely on the use of chemicals and/or ultraviolet light, which affects product quality and can be associated with adverse events in recipients. 405 nm violet-blue light is antibacterial without the use of photosensitizers and can be applied at levels safe for human exposure, making it of potential interest for decontamination of biological fluids such as plasma. As a pilot study to test whether 405 nm light is capable of inactivating bacteria in biological fluids, rabbit plasma and human plasma were seeded with bacteria and treated with a 405 nm light emitting diode (LED) exposure system (patent pending). Inactivation was achieved in all tested samples, ranging from low volumes to prebagged plasma. 99.9% reduction of low density bacterial populations (≤103 CFU mL−1), selected to represent typical “natural” contamination levels, was achieved using doses of 144 Jcm−2. The penetrability of 405 nm light, permitting decontamination of prebagged plasma, and the nonrequirement for photosensitizing agents provide a new proof of concept in bacterial reduction in biological fluids, especially injectable fluids relevant to transfusion medicine. PMID:27774337

  5. Advances in Sterilization and Decontamination: a Survey

    NASA Technical Reports Server (NTRS)

    1978-01-01

    Recent technical advances made in the field of sterilization and decontamination and their applicability to private and commercial interests are discussed. Government-sponsored programs by NASA produced the bulk of material presented in this survey. The summary of past and current research discussed is detailed to enhance an effective transfer of technology from NASA to potential users.

  6. Civilian First Responder Decontamination Equipment Characteristics Survey Results

    DTIC Science & Technology

    2010-01-01

    EQUIPMENT CHARACTERISTICS SURVEY RESULTS Scott Kooistra Shawn Bowen John Walther PROGRAM INTEGRATION DIRECTORATE Michael B. DeZearn ENGINEERING...COVERED (From - To) Mar 2007-Feb 2008 4. TITLE AND SUBTITLE Civilian First Responder Decontamination Equipment Characteristics Survey Results 5a...Department of Homeland Security/National Institute of Standards and Technology (DHS/NIST) Standards Development Team to develop a survey to

  7. Development and demonstration of techniques for reducing occupational radiation doses during refueling outages. Task 1. Steam generator channel head decontamination

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abrams, W.T.; Cope, A.W.; Orsulak, R.M.

    The overall objective of Task 1 was to demonstrate an effective method for removing tenacious corrosion products in a pressurized water reactor steam generator and thus significantly reduce radiation exposure during subsequent maintenance activities. Various decontamination methods were evaluated and a multistep, low concentration chemical process originated by Kraftwerk Union A.G. (KWU) of the Federal Republic of Germany was selected. The process was further developed and tested by C-E and KWU in West Germany and at C-E's facilities in Windsor, Connecticut. C-E designed, fabricated and tested a portable system to apply the process at Millstone Point II. The decontamination ofmore » the primary channel heads of the two Millstone steam generators was performed by C-E and NUSCO during the 1983 refueling shutdown of Millstone Point II plant. Results of the decontamination were very satisfactory. NUSCO determined that a net savings of 3660 man-rem of personnel exposure was realized during the decontamination demonstration and the subsequent maintenance work on the steam generators.« less

  8. Evaluation of Millstone-2 steam generator chemical decontamination

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Snyder, D.T.; Blok, J.

    The steam generator channel heads at Millstone-2 were decontaminated prior to carrying out extensive maintenance work in 1983. Isotopic gamma ray measurements were made of the inner channel head surfaces before and after the decontamination to evaluate the effectiveness of the process. The Combustion Engineering/Kraftwerk Union chemical decontamination, by itself, provided a decontamination factor ranging from 2.7 to 6.6 for the various steam generator surfaces. The corresponding average dose rate reduction factor, based on gross-gamma radiation surveys, was approximately 1.5 to 2.5. Following the chemical treatment, high pressure water flushing reduced the radiation levels still further, to an average overallmore » dose reduction factor of 5.3 to 7.2.« less

  9. Reduced weight decontamination formulation for neutralization of chemical and biological warfare agents

    DOEpatents

    Tucker, Mark D.

    2014-06-03

    A reduced weight DF-200 decontamination formulation that is stable under high temperature storage conditions. The formulation can be pre-packed as an all-dry (i.e., no water) or nearly-dry (i.e., minimal water) three-part kit, with make-up water (the fourth part) being added later in the field at the point of use.

  10. Use of 90% ethanol to decontaminate stethoscopes in resource limited settings.

    PubMed

    Raghubanshi, Bijendra Raj; Sapkota, Supriya; Adhikari, Arjab; Dutta, Aman; Bhattarai, Utsuk; Bhandari, Rastriyata

    2017-01-01

    In developing countries like Nepal, 90% ethanol is cheap and is available in most hospitals. The unavailability of isopropyl alcohol (IPA) in these settings led us to compare the efficacy between 90% ethanol and isopropyl alcohol pads in reducing the bacterial contamination of diaphragm of stethoscope. A randomized blinded experimental study was carried out to determine the difference between cleaning stethoscopes with 90% ethanol and IPA. Cultures of diaphragm were taken before and after cleaning with one of the cleaning agent. Colony forming units (CFU) count and organism identification was done by a blinded investigator. CFU before and after cleaning were compared using Wilcoxon signed-rank test. Mann Whitney U test was used to compare the decrease in CFU count between the cleaning agents. About 30% of the stethoscopes harbored potential pathogens. Significant reduction in CFU was observed with both IPA (Wilcoxon signed-rank test, P value <0.001) and 90% ethanol (Wilcoxon signed-rank test, P value <0.001). Comparing median decrease in CFU between cleaning with IPA and with 90% ethanol, no significant difference was found (Mann Whitney U test; U = 1357, P value >0.05). Both 90% ethanol and IPA are equally effective in decontaminating the diaphragm of stethoscope. Selection of agent should be done on the basis of cost and availability.

  11. Effects of decontamination work on riverine radiocaesium activity concentrations in Fukushima affected area

    NASA Astrophysics Data System (ADS)

    Taniguchi, K.; Onda, Y.; Yoshimura, K.; Smith, H.; Brake, W.; Kubo, T.; Kuramoto, T.; Sato, T.; Onuma, S.

    2016-12-01

    Radionuclides such as Cs-134 and Cs-137 were widely distributed in the area affected by the accident at Fukushima Daiichi nuclear power plant. The radionuclides were deposited on the surface, absorbed by soil particles, and transported via river systems to Pacific Ocean due to rainfall events. In order to reduce air dose rate surrounding residential area, decontamination works have been conducted between 2013 and 2016 Fiscal Years. In paddy field and farmland contaminated by the fallout, 5 cm of surface soil was stripped, and then clean sands put on the surface. This work could reduce radiocaesium inventory, while the coverage of vegetation was significantly decreased. Therefore, runoff characteristics in the decontaminated area were different before and after the decontamination. Activity concentrations of particulate Cs-137 were measured in Abukuma river system and 8 small catchments located in coastal zone of Fukushima affected area. In all monitoring sites, Cs-137 concentrations have decreased over an entire monitoring period. Kuchibuto river, which is a tributary of Abukuma river showed significant effect of decontamination. In Yamakiya district, in the watershed of the tributary, the decontamination work had conducted from 2013 FY to December 2015. Particulate Cs-137 concentration at two monitoring sites located in the district showed around 30% of decline in the beginning of 2014 FY whereas the decline was not so significant at sites in lower reach of the tributary. Decontaminated paddy field and farmland can be judged as the important source of suspended sediments in the tributary.

  12. Systems analysis of decontamination options for civilian vehicles.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Foltz, Greg W.; Hoette, Trisha Marie

    2010-11-01

    The objective of this project, which was supported by the Department of Homeland Security (DHS) Science and Technology Directorate (S&T) Chemical and Biological Division (CBD), was to investigate options for the decontamination of the exteriors and interiors of vehicles in the civilian setting in order to restore those vehicles to normal use following the release of a highly toxic chemical. The decontamination of vehicles is especially challenging because they often contain sensitive electronic equipment, multiple materials some of which strongly adsorb chemical agents, and in the case of aircraft, have very rigid material compatibility requirements (i.e., they cannot be exposedmore » to reagents that may cause even minor corrosion). A systems analysis approach was taken examine existing and future civilian vehicle decontamination capabilities.« less

  13. Organophosphate degrading microorganisms and enzymes as biocatalysts in environmental and personal decontamination applications.

    PubMed

    Yair, Simo; Ofer, Butnaro; Arik, Eisenkraft; Shai, Shrot; Yossi, Rosman; Tzvika, Dushnitsky; Amir, Krivoy

    2008-01-01

    One of the major challenges in dealing with chemical warfare agent (CWA) dispersal, whether in the battlefield or after a terror act, is decontamination and rehabilitation of any contaminated area. Organophosphates (OPs) are considered to be among the deadliest CWAs to date. Other OPs are used as pesticides in modern agriculture, and are considered environmentally hazardous. Current methods for OP decontamination are either dangerous or insufficiently effective. As a promising solution for this problem, bioremediation--the use of biocomponents for environmental remediation--is a potentially effective, safe, and environment-friendly method. The technology relies on several enzymatic mechanisms, and can be applied in various ways. We will review recent achievements and potential applications, such as biocatalyst-containing foams and an enzymatic sponge, for environmental as well as personal exterior decontamination.

  14. Evaluating the efficacy of hydrogen peroxide vapour against foot-and-mouth disease virus within a BSL4 biosafety facility.

    PubMed

    Petit, B M; Almeida, F C; Uchiyama, T R; Lopes, F O C; Tino, K H; Chewins, J

    2017-10-01

    An evaluation was made of the efficacy of 35% hydrogen peroxide vapour (HPV) against foot-and-mouth disease virus (FMDV) in a biosafety facility. Biological indicators (BIs) were produced using three serotypes of FMDV, all with a titre of ≥10 6 TCID 50 per ml. Fifteen BIs of each serotype were distributed across five locations, throughout a 30-m 3 airlock chamber, producing a total of 45 BIs. Thirty-five percent HPV was generated and applied using a Bioquell vaporization module located in the centre of the chamber. After a dwell period of 40 min, the HPV was removed via the enclosures air handling system and the BIs were collected. The surfaces of the BIs were recovered into Glasgow's modified Eagle's medium (GMEM), cultivated in BHK21 Cl13 cell culture and analysed for evidence of cytopathic effect (CPE). No CPE was detected in any BI sample. Positive controls showed CPE. The experimentation shows that FMDV is susceptible to HPV decontamination and presents a potential alternative to formaldehyde. Foot-and-mouth disease virus (FMDV) is an important pathogen in terms of biosafety due to its infectious nature and wide range of host animals, such as cattle, sheep, goats and pigs. Outbreaks of FMDV can have a severe impact on livestock production, causing morbidity, mortality, reduced yields and trade embargoes. Laboratories studying FMDV must possess BSL4 robust bio-decontamination methods to prevent inadvertent release. Formaldehyde has been the primary agent for environmental decontamination, but its designation as a human carcinogen has led to a search for alternatives. This study shows 35% hydrogen peroxide vapour has the potential to be a rapid, effective, residue-free alternative. © 2017 The Society for Applied Microbiology.

  15. [The role of mobile communication devices in the spread of infections].

    PubMed

    Morvai, Júlia; Szabó, Rita

    2015-05-17

    Mobile communication devices have an invaluable feature of communication within hospital, and they may support certain aspects of clinical diagnosis and education. However, there may be a risk for contamination of these devices with various pathogens. The aim of the authors was to perform a systematic review on the potential role of mobile communication devices in the dissemination of pathogens and to identify effective prevention measures. A detailed literature search was conducted using PubMed and ScienceDirect databases for papers published in English between January, 2004 and August, 2014. With the use of specific search term combinations 30 of the 216 articles met the inclusion criteria. It was found that only 8% of healthcare workers routinely cleaned their mobile communication devices resulting in a high rate of contamination (40-100%). Coagulase-negative Staphylococci and Staphylococcus aureus were the most commonly identified bacteria and most of them were methicillin resistant (10-95.3%). This systematic review identified effective interventions to reduce bacterial contamination risks including staff education, hand hygiene and regular decontamination of mobile communication devices.

  16. The Portable Chemical Sterilizer (PCS), D-FENS, and D-FEND ALL: novel chlorine dioxide decontamination technologies for the military.

    PubMed

    Doona, Christopher J; Feeherry, Florence E; Setlow, Peter; Malkin, Alexander J; Leighton, Terrence J

    2014-06-29

    There is a stated Army need for a field-portable, non-steam sterilizer technology that can be used by Forward Surgical Teams, Dental Companies, Veterinary Service Support Detachments, Combat Support Hospitals, and Area Medical Laboratories to sterilize surgical instruments and to sterilize pathological specimens prior to disposal in operating rooms, emergency treatment areas, and intensive care units. The following ensemble of novel, 'clean and green' chlorine dioxide technologies are versatile and flexible to adapt to meet a number of critical military needs for decontamination(6,15). Specifically, the Portable Chemical Sterilizer (PCS) was invented to meet urgent battlefield needs and close critical capability gaps for energy-independence, lightweight portability, rapid mobility, and rugged durability in high intensity forward deployments(3). As a revolutionary technological breakthrough in surgical sterilization technology, the PCS is a Modern Field Autoclave that relies on on-site, point-of-use, at-will generation of chlorine dioxide instead of steam. Two (2) PCS units sterilize 4 surgical trays in 1 hr, which is the equivalent throughput of one large steam autoclave (nicknamed "Bertha" in deployments because of its cumbersome size, bulky dimensions, and weight). However, the PCS operates using 100% less electricity (0 vs. 9 kW) and 98% less water (10 vs. 640 oz.), significantly reduces weight by 95% (20 vs. 450 lbs, a 4-man lift) and cube by 96% (2.1 vs. 60.2 ft(3)), and virtually eliminates the difficult challenges in forward deployments of repairs and maintaining reliable operation, lifting and transporting, and electrical power required for steam autoclaves.

  17. Potential of ozone as a fumigant to control pests in honey bee (Hymenoptera: Apidae) hives.

    PubMed

    James, R R

    2011-04-01

    Ozone is a powerful oxidant capable of killing insects and microorganisms, and eliminating odors, taste, and color. Thus, it could be useful as a fumigant to decontaminate honey comb between uses. The experiments here are intended to determine the exposure levels required to kill an insect pest and spore forming bee pathogens. Ozone was effective against greater wax moth, Galleria mellonella (L.) (Lepidoptera: Pyralidae), even on naturally infested comb. Neonates and adults were the easiest life stages to kill, requiring only a few hours of exposure, whereas eggs required a 48-h exposure (at 460-920 mg O3/m3). Two honey bee, Apis mellifera L. (Hymenoptera: Apidae), pathogens, Ascosphaera apis (a fungus that causes chalkbrood) and Paenibacillus larvae (a bacterium that causes American foulbrood), also were killed with ozone. These pathogens required much higher concentrations (3200 and 8560 mg O3/m3, respectively) and longer exposure periods (3 d) than needed to control the insects. P. larvae was effectively sterilized only when these conditions were combined with high temperature (50 degrees C) and humidity (> or =75% RH). Thus, ozone shows potential as a fumigant for bee nesting materials, but further research is needed to evaluate its acceptability and efficacy in the field. The need for a reliable method to decontaminate honey bee nesting materials as part of an overall bee health management system is discussed.

  18. Elimination of Porcine Epidemic Diarrhea Virus in an Animal Feed Manufacturing Facility.

    PubMed

    Huss, Anne R; Schumacher, Loni L; Cochrane, Roger A; Poulsen, Elizabeth; Bai, Jianfa; Woodworth, Jason C; Dritz, Steve S; Stark, Charles R; Jones, Cassandra K

    2017-01-01

    Porcine Epidemic Diarrhea Virus (PEDV) was the first virus of wide scale concern to be linked to possible transmission by livestock feed or ingredients. Measures to exclude pathogens, prevent cross-contamination, and actively reduce the pathogenic load of feed and ingredients are being developed. However, research thus far has focused on the role of chemicals or thermal treatment to reduce the RNA in the actual feedstuffs, and has not addressed potential residual contamination within the manufacturing facility that may lead to continuous contamination of finished feeds. The purpose of this experiment was to evaluate the use of a standardized protocol to sanitize an animal feed manufacturing facility contaminated with PEDV. Environmental swabs were collected throughout the facility during the manufacturing of a swine diet inoculated with PEDV. To monitor facility contamination of the virus, swabs were collected at: 1) baseline prior to inoculation, 2) after production of the inoculated feed, 3) after application of a quaternary ammonium-glutaraldehyde blend cleaner, 4) after application of a sodium hypochlorite sanitizing solution, and 5) after facility heat-up to 60°C for 48 hours. Decontamination step, surface, type, zone and their interactions were all found to impact the quantity of detectable PEDV RNA (P < 0.05). As expected, all samples collected from equipment surfaces contained PEDV RNA after production of the contaminated feed. Additionally, the majority of samples collected from non-direct feed contact surfaces were also positive for PEDV RNA after the production of the contaminated feed, emphasizing the potential role dust plays in cross-contamination of pathogen throughout a manufacturing facility. Application of the cleaner, sanitizer, and heat were effective at reducing PEDV genomic material (P < 0.05), but did not completely eliminate it.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    Purpose of the meeting was to provide a record of experience at nuclear facilities, other than TMI-2, of events and incidents which have required decontamination and dose reduction activities, and to furnish GPU and others involved in the TMI-2 cleanup with the results of that decontamination and dose reduction technology. Separate abstracts were prepared for 24 of the 25 papers; the remaining paper had been previously abstracted. (DLC)

  20. Effective responder communication improves efficiency and psychological outcomes in a mass decontamination field experiment: implications for public behaviour in the event of a chemical incident.

    PubMed

    Carter, Holly; Drury, John; Amlôt, Richard; Rubin, G James; Williams, Richard

    2014-01-01

    The risk of incidents involving mass decontamination in response to a chemical, biological, radiological, or nuclear release has increased in recent years, due to technological advances, and the willingness of terrorists to use unconventional weapons. Planning for such incidents has focused on the technical issues involved, rather than on psychosocial concerns. This paper presents a novel experimental study, examining the effect of three different responder communication strategies on public experiences and behaviour during a mass decontamination field experiment. Specifically, the research examined the impact of social identity processes on the relationship between effective responder communication, and relevant outcome variables (e.g. public compliance, public anxiety, and co-operative public behaviour). All participants (n = 111) were asked to visualise that they had been involved in an incident involving mass decontamination, before undergoing the decontamination process, and receiving one of three different communication strategies: 1) 'Theory-based communication': Health-focused explanations about decontamination, and sufficient practical information; 2) 'Standard practice communication': No health-focused explanations about decontamination, sufficient practical information; 3) 'Brief communication': No health-focused explanations about decontamination, insufficient practical information. Four types of data were collected: timings of the decontamination process; observational data; and quantitative and qualitative self-report data. The communication strategy which resulted in the most efficient progression of participants through the decontamination process, as well as the fewest observations of non-compliance and confusion, was that which included both health-focused explanations about decontamination and sufficient practical information. Further, this strategy resulted in increased perceptions of responder legitimacy and increased identification with responders, which in turn resulted in higher levels of expected compliance during a real incident, and increased willingness to help other members of the public. This study shows that an understanding of the social identity approach facilitates the development of effective responder communication strategies for incidents involving mass decontamination.

  1. Effective Responder Communication Improves Efficiency and Psychological Outcomes in a Mass Decontamination Field Experiment: Implications for Public Behaviour in the Event of a Chemical Incident

    PubMed Central

    Carter, Holly; Drury, John; Amlôt, Richard; Rubin, G. James; Williams, Richard

    2014-01-01

    The risk of incidents involving mass decontamination in response to a chemical, biological, radiological, or nuclear release has increased in recent years, due to technological advances, and the willingness of terrorists to use unconventional weapons. Planning for such incidents has focused on the technical issues involved, rather than on psychosocial concerns. This paper presents a novel experimental study, examining the effect of three different responder communication strategies on public experiences and behaviour during a mass decontamination field experiment. Specifically, the research examined the impact of social identity processes on the relationship between effective responder communication, and relevant outcome variables (e.g. public compliance, public anxiety, and co-operative public behaviour). All participants (n = 111) were asked to visualise that they had been involved in an incident involving mass decontamination, before undergoing the decontamination process, and receiving one of three different communication strategies: 1) ‘Theory-based communication’: Health-focused explanations about decontamination, and sufficient practical information; 2) ‘Standard practice communication’: No health-focused explanations about decontamination, sufficient practical information; 3) ‘Brief communication’: No health-focused explanations about decontamination, insufficient practical information. Four types of data were collected: timings of the decontamination process; observational data; and quantitative and qualitative self-report data. The communication strategy which resulted in the most efficient progression of participants through the decontamination process, as well as the fewest observations of non-compliance and confusion, was that which included both health-focused explanations about decontamination and sufficient practical information. Further, this strategy resulted in increased perceptions of responder legitimacy and increased identification with responders, which in turn resulted in higher levels of expected compliance during a real incident, and increased willingness to help other members of the public. This study shows that an understanding of the social identity approach facilitates the development of effective responder communication strategies for incidents involving mass decontamination. PMID:24595097

  2. Industrial Technology of Decontamination of Liquid Radioactive Waste in SUE MosSIA 'Radon' - 12371

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adamovich, Dmitry V.; Neveykin, Petr P.; Karlin, Yuri V.

    SUE MosSIA 'RADON' - this enterprise was created more than 50 years ago, which deals with the recycling of radioactive waste and conditioning of spent sources of radiation in stationary and mobile systems in the own factory and operating organizations. Here is represented the experience SUE MosSIA 'Radon' in the field of the management with liquid radioactive waste. It's shown, that the activity of SUE MosSIA 'RADON' is developing in three directions - improvement of technical facilities for treatment of radioactive waters into SUE MosSIA 'RADON' development of mobile equipment for the decontamination of radioactive waters in other organizations, developmentmore » of new technologies for decontamination of liquid radioactive wastes as part of various domestic Russian and international projects including those related to the operation of nuclear power and nuclear submarines. SUE MosSIA 'RADON' has processed more than 270 thousand m{sup 3} of radioactive water, at that more than 7000 m{sup 3} in other organizations for more than 50 years. It is shown that a number of directions, particularly, the development of mobile modular units for decontamination of liquid radioactive waste, SUE MosSIA 'RADON' is a leader in the world. (authors)« less

  3. Conversion of transuranic waste to low level waste by decontamination: a site specific update

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Allen, R.P.; Hazelton, R.F.

    1985-09-01

    As a followup to an FY-1984 cost/benefit study, a program was conducted in FY-1985 to transfer to the relevant DOE sites the information and technology for the direct conversion of transuranic (TRU) waste to low-level waste (LLW) by decontamination. As part of this work, the economic evaluation of the various TRUW volume reduction and conversion options was updated and expanded to include site-specific factors. The results show, for the assumptions used, that size reduction, size reduction followed by decontamination, or in situ decontamination are cost effective compared with the no-processing option. The technology transfer activities included site presentations and discussionsmore » with operations and waste management personnel to identify application opportunities and site-specific considerations and constraints that could affect the implementation of TRU waste conversion principles. These discussions disclosed definite potential for the beneficial application of these principles at most of the sites, but also confirmed the existence of site-specific factors ranging from space limitations to LLW disposal restrictions that could preclude particular applications or diminish expected benefits. 8 refs., 2 figs., 4 tabs.« less

  4. Volunteer trials of a novel improvised dry decontamination protocol for use during mass casualty incidents as part of the UK'S Initial Operational Response (IOR).

    PubMed

    Amlôt, Richard; Carter, Holly; Riddle, Lorna; Larner, Joanne; Chilcott, Robert P

    2017-01-01

    Previous studies have demonstrated that rapid evacuation, disrobing and emergency decontamination can enhance the ability of emergency services and acute hospitals to effectively manage chemically-contaminated casualties. The purpose of this human volunteer study was to further optimise such an "Initial Operational Response" by (1) identifying an appropriate method for performing improvised skin decontamination and (2) providing guidance for use by first responders and casualties. The study was performed using two readily available, absorbent materials (paper towels and incontinence pads). The decontamination effectiveness of the test materials was measured by quantifying the amount of a chemical warfare agent simulant (methyl salicylate) removed from each volunteer's forearm skin. Results from the first study demonstrated that simulant recovery was lower in all of the dry decontamination conditions when compared to matched controls, suggesting that dry decontamination serves to reduce chemical exposure. Blotting in combination with rubbing was the most effective form of decontamination. There was no difference in effectiveness between the two absorbent materials. In the following study, volunteers performed improvised dry decontamination, either with or without draft guidelines. Volunteers who received the guidance were able to carry out improvised dry decontamination more effectively, using more of the absorbent product (blue roll) to ensure that all areas of the body were decontaminated and avoiding cross-contamination of other body areas by working systematically from the head downwards. Collectively, these two studies suggest that absorbent products that are available on ambulances and in acute healthcare settings may have generic applicability for improvised dry decontamination. Wherever possible, emergency responders and healthcare workers should guide casualties through decontamination steps; in the absence of explicit guidance and instructions, improvised dry decontamination may not be performed correctly or safely.

  5. Volunteer trials of a novel improvised dry decontamination protocol for use during mass casualty incidents as part of the UK’S Initial Operational Response (IOR)

    PubMed Central

    Riddle, Lorna; Larner, Joanne

    2017-01-01

    Previous studies have demonstrated that rapid evacuation, disrobing and emergency decontamination can enhance the ability of emergency services and acute hospitals to effectively manage chemically-contaminated casualties. The purpose of this human volunteer study was to further optimise such an “Initial Operational Response” by (1) identifying an appropriate method for performing improvised skin decontamination and (2) providing guidance for use by first responders and casualties. The study was performed using two readily available, absorbent materials (paper towels and incontinence pads). The decontamination effectiveness of the test materials was measured by quantifying the amount of a chemical warfare agent simulant (methyl salicylate) removed from each volunteer’s forearm skin. Results from the first study demonstrated that simulant recovery was lower in all of the dry decontamination conditions when compared to matched controls, suggesting that dry decontamination serves to reduce chemical exposure. Blotting in combination with rubbing was the most effective form of decontamination. There was no difference in effectiveness between the two absorbent materials. In the following study, volunteers performed improvised dry decontamination, either with or without draft guidelines. Volunteers who received the guidance were able to carry out improvised dry decontamination more effectively, using more of the absorbent product (blue roll) to ensure that all areas of the body were decontaminated and avoiding cross-contamination of other body areas by working systematically from the head downwards. Collectively, these two studies suggest that absorbent products that are available on ambulances and in acute healthcare settings may have generic applicability for improvised dry decontamination. Wherever possible, emergency responders and healthcare workers should guide casualties through decontamination steps; in the absence of explicit guidance and instructions, improvised dry decontamination may not be performed correctly or safely. PMID:28622352

  6. Ultra Pure Water Cleaning Baseline Study on NASA JSC Astromaterial Curation Gloveboxes

    NASA Technical Reports Server (NTRS)

    Calaway, Michael J.; Burkett, P. J.; Allton, J. H.; Allen, C. C.

    2013-01-01

    Future sample return missions will require strict protocols and procedures for reducing inorganic and organic contamination in isolation containment systems. In 2012, a baseline study was orchestrated to establish the current state of organic cleanliness in gloveboxes used by NASA JSC astromaterials curation labs [1, 2]. As part of this in-depth organic study, the current curatorial technical support procedure (TSP) 23 was used for cleaning the gloveboxes with ultra pure water (UPW) [3-5]. Particle counts and identification were obtained that could be used as a benchmark for future mission designs that require glovebox decontamination. The UPW baseline study demonstrates that TSP 23 works well for gloveboxes that have been thoroughly degreased. However, TSP 23 could be augmented to provide even better glovebox decontamination. JSC 03243 could be used as a starting point for further investigating optimal cleaning techniques and procedures. DuPont Vertrel XF or other chemical substitutes to replace Freon- 113, mechanical scrubbing, and newer technology could be used to enhance glovebox cleanliness in addition to high purity UPW final rinsing. Future sample return missions will significantly benefit from further cleaning studies to reduce inorganic and organic contamination.

  7. Decontamination & decommissioning focus area

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-08-01

    In January 1994, the US Department of Energy Office of Environmental Management (DOE EM) formally introduced its new approach to managing DOE`s environmental research and technology development activities. The goal of the new approach is to conduct research and development in critical areas of interest to DOE, utilizing the best talent in the Department and in the national science community. To facilitate this solutions-oriented approach, the Office of Science and Technology (EM-50, formerly the Office of Technology Development) formed five Focus AReas to stimulate the required basic research, development, and demonstration efforts to seek new, innovative cleanup methods. In Februarymore » 1995, EM-50 selected the DOE Morgantown Energy Technology Center (METC) to lead implementation of one of these Focus Areas: the Decontamination and Decommissioning (D & D) Focus Area.« less

  8. Benefits of automated surface decontamination of a radioiodine ward.

    PubMed

    Westcott, Eliza; Broadhurst, Alicia; Crossley, Steven; Lee, Lloyd; Phan, Xuyen; Scharli, Rainer; Xu, Yan

    2012-02-01

    A floor-washing robot has been acquired to assist physicists with decontamination of radioiodine therapy ward rooms after discharge of the patient at Sir Charles Gairdner Hospital. The effectiveness of the robot in decontaminating the ward has been evaluated. A controlled experiment was performed by deliberately contaminating a polyvinyl chloride flooring offcut with 131I followed by automated decontamination with the robot. The extent of fixed and removable contamination was assessed before and after decontamination by two methods: (1) direct Geiger-Mueller counting and (2) beta-counting wipe tests. Surface contamination was also assessed in situ on the ward by Geiger-Mueller counting and wipe testing. Contamination maps confirmed that contamination was removed rather than spread around by the robot. Wipe testing revealed that the robot was successful in clearing approximately 60-80% of removable contamination. The robotic floor-washing device was considered suitable to provide effective automated decontamination of the radioiodine ward. In addition, the robot affords other benefits: the time spent by the physicists decontaminating the room is greatly reduced offering financial and occupational safety and health benefits. The robot has also found utility in other decontamination applications in the healthcare environment.

  9. Inactivation of E.coli 0157:H7 and Salmonella enterica on strawberries by sanitizing solutions

    USDA-ARS?s Scientific Manuscript database

    A recent foodborne outbreak of E. coli O157:H7 in Oregon associated with the consumption of fresh strawberries highlights the need for effective sanitizing washes, suitable for the inactivation of pathogens on fresh produce. Sanitizing solutions were screened for decontaminating E. coli O157:H7 (E...

  10. A novel model to assess the efficacy of steam surface pasteurization of cooked surimi gels inoculated with realistic levels of Listeria innocua.

    PubMed

    Skåra, Torstein; Valdramidis, Vasilis P; Rosnes, Jan Thomas; Noriega, Estefanía; Van Impe, Jan F M

    2014-12-01

    Steam surface pasteurization is a promising decontamination technology for reducing pathogenic bacteria in different stages of food production. The effect of the artificial inoculation type and initial microbial load, however, has not been thoroughly assessed in the context of inactivation studies. In order to optimize the efficacy of the technology, the aim of this study was to design and validate a model system for steam surface pasteurization, assessing different inoculation methods and realistic microbial levels. More specifically, the response of Listeria innocua, a surrogate organism of Listeria monocytogenes, on a model fish product, and the effect of different inoculation levels following treatments with a steam surface pasteurization system was investigated. The variation in the resulting inoculation level on the samples was too large (77%) for the contact inoculation procedure to be further considered. In contrast, the variation of a drop inoculation procedure was 17%. Inoculation with high levels showed a rapid 1-2 log decrease after 3-5 s, and then no further inactivation beyond 20 s. A low level inoculation study was performed by analysing the treated samples using a novel contact plating approach, which can be performed without sample homogenization and dilution. Using logistic regression, results from this method were used to model the binary responses of Listeria on surfaces with realistic inoculation levels. According to this model, a treatment time of 23 s will result in a 1 log reduction (for P = 0.1). Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Exploratory Use of Microaerosol Decontamination Technology (PAEROSOL) in Enclosed, Unoccupied Hospital Setting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rainina, Evguenia I.; McCune, D. E.; Luna, Maria L.

    2012-05-31

    The goal of this study was to validate the previously observed high biological kill performance of PAEROSOL, a semi-dry, micro-aerosol decontamination technology, against common HAI in a non-human subject trial within a hospital setting of Madigan Army Medical Center (MAMC) on Joint Base Lewis-McChord in Tacoma, Washington. In addition to validating the disinfecting efficacy of PAEROSOL, the objectives of the trial included a demonstration of PAEROSOL environmental safety, (i.e., impact to hospital interior materials and electronic equipment exposed during testing) and PAEROSOL parameters optimization for future deployment.

  12. Survival of Salmonella on refrigerated chicken carcasses and subsequent transfer to cutting board.

    PubMed

    Jiménez, S M; Tiburzi, M C; Salsi, M S; Moguilevsky, M A; Pirovani, M E

    2009-06-01

    To determine the effect of refrigeration time and temperature on Salmonella cell numbers on inoculated chicken carcasses and their transfer to a plastic cutting board. The survival of Salmonella on chicken skin and the transfer to a plastic cutting board when exposed to different refrigeration temperatures (2, 6 or 8 degrees C) for 9 days were the two main issues on which this work focused. Two scenarios were carried out to ascertain these effects: carcasses treated with a decontaminating acetic acid solution and untreated carcasses. All of the contaminated carcasses remained contaminated after 9 days of refrigeration. However, on untreated samples, while Salmonella numbers increased almost 1.5 log at 8 degrees C, the pathogen numbers decreased about 1 log at 2 and 6 degrees C. On acid-treated samples, cell numbers slightly decreased at all of the temperatures studied. Temperature did not affect salmonellae transfer to the cutting board, but time did. Acid decontamination increased cell numbers transferred to the cutting board compared with untreated samples. Proper refrigeration at low temperatures did not allow Salmonella numbers to rise, regardless of which carcasses had been, or had not been, acid treated. Despite the fact that the rate of transfer was not affected by temperature, the acid treatment detached Salmonella cells from the chicken skin and, therefore, the probability of greater cross-contamination should be studied further. The results of this study may provide better information about the refrigeration conditions for fresh chicken storage and also determine if these, along with acetic acid decontamination of broiler chicken, would affect the pathogen transfer to a cutting board.

  13. Fate of Salmonella enterica and Enterohemorrhagic Escherichia coli Cells Artificially Internalized into Vegetable Seeds during Germination.

    PubMed

    Liu, Da; Cui, Yue; Walcott, Ronald; Chen, Jinru

    2018-01-01

    Vegetable seeds contaminated with bacterial pathogens have been linked to fresh-produce-associated outbreaks of gastrointestinal infections. This study was undertaken to observe the physiological behavior of Salmonella enterica and enterohemorrhagic Escherichia coli (EHEC) cells artificially internalized into vegetable seeds during the germination process. Surface-decontaminated seeds of alfalfa, fenugreek, lettuce, and tomato were vacuum-infiltrated with four individual strains of Salmonella or EHEC. Contaminated seeds were germinated at 25°C for 9 days, and different sprout/seedling tissues were microbiologically analyzed every other day. The internalization of Salmonella and EHEC cells into vegetable seeds was confirmed by the absence of pathogens in seed-rinsing water and the presence of pathogens in seed homogenates after postinternalization seed surface decontamination. Results show that 317 (62%) and 343 (67%) of the 512 collected sprout/seedling tissue samples were positive for Salmonella and EHEC, respectively. The average Salmonella populations were significantly larger ( P < 0.05) than the EHEC populations. Significantly larger Salmonella populations were recovered from the cotyledon and seed coat tissues, followed by the root tissues, but the mean EHEC populations from all sampled tissue sections were statistically similar, except in pregerminated seeds. Three Salmonella and two EHEC strains had significantly larger cell populations on sprout/seedling tissues than other strains used in the study. Salmonella and EHEC populations from fenugreek and alfalfa tissues were significantly larger than those from tomato and lettuce tissues. The study showed the fate of internalized human pathogens on germinating vegetable seeds and sprout/seedling tissues and emphasized the importance of using pathogen-free seeds for sprout production. IMPORTANCE The internalization of microorganisms into vegetable seeds could occur naturally and represents a possible pathway of vegetable seed contamination by human pathogens. The present study investigated the ability of two important bacterial pathogens, Salmonella and enterohemorrhagic Escherichia coli (EHEC), when artificially internalized into vegetable seeds, to grow and disseminate along vegetable sprouts/seedlings during germination. The data from the study revealed that the pathogen cells artificially internalized into vegetable seeds caused the contamination of different tissues of sprouts/seedlings and that pathogen growth on germinating seeds is bacterial species and vegetable seed-type dependent. These results further stress the necessity of using pathogen-free vegetable seeds for edible sprout production. Copyright © 2017 American Society for Microbiology.

  14. 2013 Consequence Management Advisory Team (CMAT) Annual Report

    EPA Pesticide Factsheets

    Chemical, Biological, Radiological and Nuclear CMAT reviews use of data tools such as Airborne Spectral Photometric Environmental Collection Technology, new sampling and decontamination techniques, new response technologies, and improvement potential.

  15. Laser decontamination and decomposition of PCB-containing paint

    NASA Astrophysics Data System (ADS)

    Anthofer, A.; Kögler, P.; Friedrich, C.; Lippmann, W.; Hurtado, A.

    2017-01-01

    Decontamination of concrete surfaces contaminated with paint containing polychlorinated biphenyls is an elaborate and complex task that must be performed within the scope of nuclear power plant dismantling as well as conventional pollutant cleanup in buildings. The state of the art is mechanical decontamination, which generates dust as well as secondary waste and is both dangerous and physically demanding. Moreover, the ablated PCB-containing paint has to be treated in a separate process step. Laser technology offers a multitude of possibilities for contactless surface treatment with no restoring forces and a high potential for automation. An advanced experimental setup was developed for performing standard laser decontamination investigations on PCB-painted concrete surfaces. As tested with epoxy paints, a high-power diode laser with a laser power of 10 kW in continuous wave (CW) mode was implemented and resulted in decontamination of the concrete surfaces as well as significant PCB decomposition. The experimental results showed PCB removal of 96.8% from the concrete surface and PCB decomposition of 88.8% in the laser decontamination process. Significant PCDD/F formation was thereby avoided. A surface ablation rate of approx. 7.2 m2/h was realized.

  16. Method for the decontamination of metallic surfaces

    DOEpatents

    Purohit, Ankur; Kaminski, Michael D.; Nunez, Luis

    2003-01-01

    A method of decontaminating a radioactively contaminated oxide on a surface. The radioactively contaminated oxide is contacted with a diphosphonic acid solution for a time sufficient to dissolve the oxide and subsequently produce a precipitate containing most of the radioactive values. Thereafter, the diphosphonic solution is separated from the precipitate. HEDPA is the preferred diphosphonic acid and oxidizing and reducing agents are used to initiate precipitation. SFS is the preferred reducing agent.

  17. PATHOGEN EQUIVALENCY COMMITTEE (PEC)

    EPA Science Inventory

    The U.S. Environmental Protection Agency created the PEC in 1985 to make recommendations to EPA and State managers on the equivalency of unproven sewage sludge disinfection technologies/processes to either a Process to Significantly Reduce Pathogens (PSRP) or a Process to Further...

  18. Removal of uranyl ions by p-hexasulfonated calyx[6]arene acid

    NASA Astrophysics Data System (ADS)

    Popescu (Hoştuc), Ioana-Carmen; Petru, Filip; Humelnicu, Ionel; Mateescu, Marina; Militaru, Ecaterina; Humelnicu, Doina

    2014-10-01

    Radioactive pollution is a significant threat for the people's health. Therefore highly effective radioactive decontamination methods are required. Ion exchange, biotechnologies and phytoremediation in constructed wetlands have been used as radioactive decontamination technologies for uranium contaminated soil and water remediation. Recently, beside those classical methods the calix[n]arenic derivatives' utilization as radioactive decontaminators has jogged attention. The present work aims to present the preliminary research results of uranyl ion sorption studies on the p-hexasulfonated calyx[6]arenic acid. The effect of temperature, contact time, sorbent amount and uranyl concentration variation on sorption efficiency was investigated. Isotherm models revealed that the sorption process fit better Langmuir isotherm.

  19. NANOSTRUCTURED MATERIALS FOR ENVIRONMENTAL DECONTAMINATION OF CHLORINATED COMPOUNDS

    EPA Science Inventory

    The investigators have developed multifunctional particles that involve important elements of a successful technology to remediate TCE.

    The following are key aspects of the technology that distinguish it from other existing technologies:

    1. Relat...

    2. Technology Evaluation Report: Non-destructive ...

      EPA Pesticide Factsheets

      Technology Evaluation Report HSRP is working to develop tools and information that will help detect the intentional introduction of chemical or biological contaminants in buildings or water systems, the containment of these contaminants, the decontamination of buildings and/or water systems, and the management of wastes generated from decontamination and cleanup operations. Evaluation of the performance of CBI Polymers’ DeconGelTM 1108, Environmental Alternatives, Inc.’s (EAI’s) Rad-Release II (RRII), Environmental Alternatives, Inc.’s SuperGel, and Intek Technologies’ LH-21. The objective of evaluating these technologies was to test their ability to remove radioactive cesium (Cs)-137 from the mixed building material coupons of brick with mortar, tile with grout, granite with mortar, all mortar and all grout coupons.

  1. Emerging Technologies and Techniques for Wide Area Radiological Survey and Remediation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sutton, M.; Zhao, P.

    2016-03-24

    Technologies to survey and decontaminate wide-area contamination and process the subsequent radioactive waste have been developed and implemented following the Chernobyl nuclear power plant release and the breach of a radiological source resulting in contamination in Goiania, Brazil. These civilian examples of radioactive material releases provided some of the first examples of urban radiological remediation. Many emerging technologies have recently been developed and demonstrated in Japan following the release of radioactive cesium isotopes (Cs-134 and Cs-137) from the Fukushima Dai-ichi nuclear power plant in 2011. Information on technologies reported by several Japanese government agencies, such as the Japan Atomic Energymore » Agency (JAEA), the Ministry of the Environment (MOE) and the National Institute for Environmental Science (NIES), together with academic institutions and industry are summarized and compared to recently developed, deployed and available technologies in the United States. The technologies and techniques presented in this report may be deployed in response to a wide area contamination event in the United States. In some cases, additional research and testing is needed to adequately validate the technology effectiveness over wide areas. Survey techniques can be deployed on the ground or from the air, allowing a range of coverage rates and sensitivities. Survey technologies also include those useful in measuring decontamination progress and mapping contamination. Decontamination technologies and techniques range from non-destructive (e.g., high pressure washing) and minimally destructive (plowing), to fully destructive (surface removal or demolition). Waste minimization techniques can greatly impact the long-term environmental consequences and cost following remediation efforts. Recommendations on technical improvements to address technology gaps are presented together with observations on remediation in Japan.« less

  2. Electrolytic decontamination of conductive materials

    NASA Astrophysics Data System (ADS)

    Campbell, George M.; Nelson, Timothy O.; Parker, John L.; Getty, Richard H.; Hergert, Tom R.; Lindahl, Kirk A.; Peppers, Larry G.

    1994-10-01

    Using the electrolytic method, we have demonstrated removal of Pu and Am from contaminated conductive material. At EG and G /Rocky Flats, we electrolytically decontaminated stainless steel. Results from this work show removal of fixed contamination, including the following geometries: planar, large radius, bolt holes, glove ports, and protruding studs. More specifically, fixed contamination was reduced from levels ranging from greater than 1 000 000 counts per minute (cpm) down to levels ranging from 1500 to 250 cpm using the electrolytic method. More recently, the electrolytic work has continued at Los Alamos National Laboratory as a joint project with EG and G/Rocky Flats. Impressively, electrolytic decontamination of Pu /Am from U surfaces (10 sq cm per side) shows decreases in swipable contamination from 500 000-1 500 000 disintegrations per minute (dpm) down to 0-2 dpm. Moreover, the solid waste product of the electrolytic method is reduced in volume by more than 50 times compared with the liquid waste produced by the previous U decontamination method -- a hot concentrated acid spray leach process.

  3. Decontamination of metals using chemical etching

    DOEpatents

    Lerch, Ronald E.; Partridge, Jerry A.

    1980-01-01

    The invention relates to chemical etching process for reclaiming contaminated equipment wherein a reduction-oxidation system is included in a solution of nitric acid to contact the metal to be decontaminated and effect reduction of the reduction-oxidation system, and includes disposing a pair of electrodes in the reduced solution to permit passage of an electrical current between said electrodes and effect oxidation of the reduction-oxidation system to thereby regenerate the solution and provide decontaminated equipment that is essentially radioactive contamination-free.

  4. Dental unit water lines decontamination with the aid of nanotechnology.

    PubMed

    Paramashivaiah, Rashmi; Prabhuji, M L V; Narayanan, Roopalakshmi

    2016-01-01

    This article reviews the issue of dental unit waterline (DUWL) contamination which affects all the clinical and hospital settings. The contaminating microorganisms commonly isolated from these settings and the most pathogenic among them have serious consequences. Over the years several measures are inculcated for decontamination of water, their advantages and shortcomings have been addressed. Options using nanotechnology which are available in the market are described briefly. A manual and electronic search was conducted. Google and PubMed were searched for relevant material from studies up to 2013. Medical Subject Headings words looked for were "Nanotechnology," "Water purification," and "Biofilms." Reviewed findings were summarized by topic, using the Preferred Reporting Items for Systematic Reviews and Meta-analyses statement for reporting. Seventy articles were shortlisted for articles pertaining to our topic of discussion. A systematic approach was followed by two independent reviewers and included eligibility criteria for study inclusion, data extraction, data synthesis, and drawing of conclusion. Dental waterline contamination is widespread in any type of dental setting having serious implications on clinicians and patients alike, especially elderly and immune-compromised. Hence, international bodies like center for disease and control and American Dental Association have come up with stringent measures for maintenance of water quality. A gamut of procedures has been tried to overcome this problem ranging from chlorinated products, water filters to the usage of distilled water. The use of nanoemulsions, nanofilters, nanomembranes, etc., and their applicability for routine usage is discussed. Biofilm formation in DUWLs is inevitable with the subsequent release of part of microbiota into the otherwise sterile dental settings. These consequences can be quite serious on clinicians and dental patients. Though conventional measures in water decontamination have been partly successful, the quest for more foolproof methods has led to the use of latest technology, i.e., nanotechnology. The most practical option has to be chosen based on the ease of their usage.

  5. Report of decontamination at Tominari Elementary School.

    PubMed

    Katsumi, S

    2016-12-01

    On 19 April 2011, the Ministry of Education, Culture, Sports, Science, and Technology designated 13 elementary schools, including Tominari Elementary School in Date city, as high-dose schools that needed to restrict outdoor activities due to the effects of the accident at Fukushima Daiichi nuclear power plant. Approximately 1 week later, the municipal government took action to remove the topsoil from the school grounds, and the prohibition of outdoor activities at Tominari Elementary School was lifted. The school staff continued to work on decontaminating the surrounding areas using high-pressure washers and brushes. There were certain positive outcomes, but a more effective decontamination method was required. In July 2011, the municipal government started an environmental remediation project, both inside and outside the school buildings, with researchers and decontamination workers at Tominari Elementary School, involving members of the Parent-Teacher Association (PTA), local communities, and volunteers using various effective and specialised forms of decontamination. As a result, Tominari Elementary School was able to recommence swimming lessons at the end of the first semester, which had been thought to be impossible. This article will provide information about the importance of 'dialogue' for decontamination, how engagement of the experts gave members of the PTA and the local community a feeling of 'security and safety', and how the decontamination work was an ever-expanding collaborative work of a large number of people.

  6. Optimization of chitosan treatments for managing microflora in lettuce seeds without affecting germination.

    PubMed

    Goñi, M G; Moreira, M R; Viacava, G E; Roura, S I

    2013-01-30

    Many studies have focused on seed decontamination but no one has been capable of eliminating all pathogenic bacteria. Two objectives were followed. First, to assess the in vitro antimicrobial activity of chitosan against: (a) Escherichia coli O157:H7, (b) native microflora of lettuce and (c) native microflora of lettuce seeds. Second, to evaluate the efficiency of chitosan on reducing microflora on lettuce seeds. The overall goal was to find a combination of contact time and chitosan concentration that reduces the microflora of lettuce seeds, without affecting germination. After treatment lettuce seeds presented no detectable microbial counts (<10(2)CFU/50 seeds) for all populations. Moreover, chitosan eliminated E. coli. Regardless of the reduction in the microbial load, a 90% reduction on germination makes imbibition with chitosan, uneconomical. Subsequent treatments identified the optimal treatment as 10 min contact with a 10 g/L chitosan solution, which maintained the highest germination percentage. Copyright © 2012 Elsevier Ltd. All rights reserved.

  7. Foam and gel methods for the decontamination of metallic surfaces

    DOEpatents

    Nunez, Luis; Kaminski, Michael Donald

    2007-01-23

    Decontamination of nuclear facilities is necessary to reduce the radiation field during normal operations and decommissioning of complex equipment. In this invention, we discuss gel and foam based diphosphonic acid (HEDPA) chemical solutions that are unique in that these solutions can be applied at room temperature; provide protection to the base metal for continued applications of the equipment; and reduce the final waste form production to one step. The HEDPA gels and foams are formulated with benign chemicals, including various solvents, such as ionic liquids and reducing and complexing agents such as hydroxamic acids, and formaldehyde sulfoxylate. Gel and foam based HEDPA processes allow for decontamination of difficult to reach surfaces that are unmanageable with traditional aqueous process methods. Also, the gel and foam components are optimized to maximize the dissolution rate and assist in the chemical transformation of the gel and foam to a stable waste form.

  8. Activity of a dry mist hydrogen peroxide system against environmental Clostridium difficile contamination in elderly care wards.

    PubMed

    Shapey, S; Machin, K; Levi, K; Boswell, T C

    2008-10-01

    Clostridium difficile causes serious healthcare-associated infections. Infection control is difficult, due in part to environmental contamination with C. difficile spores. These spores are relatively resistant to cleaning and disinfection. The activity of a dry mist hydrogen peroxide decontamination system (Sterinis) against environmental C. difficile contamination was assessed in three elderly care wards. Initial sampling for C. difficile was performed in 16 rooms across a variety of wards and specialties, using Brazier's CCEY (cycloserine-cefoxitin-egg yolk) agar. Ten rooms for elderly patients (eight isolation and two sluice rooms) were then resampled following dry mist hydrogen peroxide decontamination. Representative isolates of C. difficile were typed by polymerase chain reaction ribotyping. C. difficile was recovered from 3%, 11% and 26% of samples from low, medium and high risk rooms, respectively. In 10 high risk elderly care rooms, 24% (48/203) of samples were positive for C. difficile, with a mean of 6.8 colony-forming units (cfu) per 10 samples prior to hydrogen peroxide decontamination. Ribotyping identified the presence of the three main UK epidemic strains (ribotypes 001, 027 and 106) and four rooms contained mixed strains. After a single cycle of hydrogen peroxide decontamination, only 3% (7/203) of samples were positive (P<0.001), with a mean of 0.4 cfu per 10 samples ( approximately 94% reduction). The Sterinis hydrogen peroxide system significantly reduced the extent of environmental contamination with C. difficile in these elderly care rooms. This relatively quick and user-friendly technology might be a more reliable method of terminally disinfecting isolation rooms, following detergent cleaning, compared to the manual application of other disinfectants.

  9. Review of the MDF-LSA 100 Spray Decontamination System

    DTIC Science & Technology

    2011-12-01

    decontamination technology. In October 2000, SNL received funding from the U.S. Department of Energy’s and National Nuclear Security Administration’s...UNCLASSIFIED DSTO-GD-0662 The MDF-LSA 200 is supplied or created as a foam, liquid or aerosol. The foam can be sprayed from handheld canisters . When the foam...DSTO Publications Repository http://dspace.dsto.defence.gov.au/dspace/ 14. RELEASE AUTHORITY Chief, Human Protection and Performance

  10. Evaluation of the Effects of Hydrogen Peroxide on Common Aviation Structural Materials

    DTIC Science & Technology

    2009-12-01

    population of Geobacillus stearothermophilus . Once the sanitization/ decontamination phase is completed, the enclosure is 1 VHP is a registered...disinfection and/or decon- tamination technologies available, vaporized hydrogen peroxide (VHP)1 is of particular interest because it can be rapidly sterilized ...decontamination Unit (STERIS Corporation, Mentor, OH, USA) using VAPROX®2 as the sterilant in an enclosed chamber for 1, 10, or 25 VHP cycles . The exposure

  11. Improvement of Biological Indicators by Uniformly Distributing Bacillus subtilis Spores in Monolayers To Evaluate Enhanced Spore Decontamination Technologies

    PubMed Central

    Raguse, Marina; Fiebrandt, Marcel; Stapelmann, Katharina; Madela, Kazimierz; Laue, Michael; Lackmann, Jan-Wilm; Thwaite, Joanne E.; Setlow, Peter; Awakowicz, Peter

    2016-01-01

    Novel decontamination technologies, including cold low-pressure plasma and blue light (400 nm), are promising alternatives to conventional surface decontamination methods. However, the standardization of the assessment of such sterilization processes remains to be accomplished. Bacterial endospores of the genera Bacillus and Geobacillus are frequently used as biological indicators (BIs) of sterility. Ensuring standardized and reproducible BIs for reliable testing procedures is a significant problem in industrial settings. In this study, an electrically driven spray deposition device was developed, allowing fast, reproducible, and homogeneous preparation of Bacillus subtilis 168 spore monolayers on glass surfaces. A detailed description of the structural design as well as the operating principle of the spraying device is given. The reproducible formation of spore monolayers of up to 5 × 107 spores per sample was verified by scanning electron microscopy. Surface inactivation studies revealed that monolayered spores were inactivated by UV-C (254 nm), low-pressure argon plasma (500 W, 10 Pa, 100 standard cubic cm per min), and blue light (400 nm) significantly faster than multilayered spores were. We have thus succeeded in the uniform preparation of reproducible, highly concentrated spore monolayers with the potential to generate BIs for a variety of nonpenetrating surface decontamination techniques. PMID:26801572

  12. Robotics crosscutting program: Technology summary

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    The Office of Environmental Management (EM) is responsible for cleaning up the legacy of radioactive and chemically hazardous waste at contaminated sites and facilities throughout the U.S. Department of Energy (DOE) nuclear weapons complex, preventing further environmental contamination, and instituting responsible environmental management. Initial efforts to achieve this mission resulted in the establishment of environmental restoration and waste management programs. However, as EM began to execute its responsibilities, decision makers became aware that the complexity and magnitude of this mission could not be achieved efficiently, affordably, safely, or reasonably with existing technology. Once the need for advanced cleanup technologies becamemore » evident, EM established an aggressive, innovative program of applied research and technology development. The Office of Technology Development (OTD) was established in November 1989 to advance new and improved environmental restoration and waste management technologies that would reduce risks to workers, the public, and the environment; reduce cleanup costs; and devise methods to correct cleanup problems that currently have no solutions. In 1996, OTD added two new responsibilities - management of a Congressionally mandated environmental science program and development of risk policy, requirements, and guidance. OTD was renamed the Office of Science and Technology (OST). This documents presents information concerning robotics tank waste retrieval overview, robotic chemical analysis automation, robotics decontamination and dismantlement, and robotics crosscutting and advanced technology.« less

  13. The Portable Chemical Sterilizer (PCS), D-FENS, and D-FEND ALL: Novel Chlorine Dioxide Decontamination Technologies for the Military

    PubMed Central

    Doona, Christopher J.; Feeherry, Florence E.; Setlow, Peter; Malkin, Alexander J.; Leighton, Terrence J.

    2014-01-01

    There is a stated Army need for a field-portable, non-steam sterilizer technology that can be used by Forward Surgical Teams, Dental Companies, Veterinary Service Support Detachments, Combat Support Hospitals, and Area Medical Laboratories to sterilize surgical instruments and to sterilize pathological specimens prior to disposal in operating rooms, emergency treatment areas, and intensive care units. The following ensemble of novel, ‘clean and green’ chlorine dioxide technologies are versatile and flexible to adapt to meet a number of critical military needs for decontamination6,15. Specifically, the Portable Chemical Sterilizer (PCS) was invented to meet urgent battlefield needs and close critical capability gaps for energy-independence, lightweight portability, rapid mobility, and rugged durability in high intensity forward deployments3. As a revolutionary technological breakthrough in surgical sterilization technology, the PCS is a Modern Field Autoclave that relies on on-site, point-of-use, at-will generation of chlorine dioxide instead of steam. Two (2) PCS units sterilize 4 surgical trays in 1 hr, which is the equivalent throughput of one large steam autoclave (nicknamed “Bertha” in deployments because of its cumbersome size, bulky dimensions, and weight). However, the PCS operates using 100% less electricity (0 vs. 9 kW) and 98% less water (10 vs. 640 oz.), significantly reduces weight by 95% (20 vs. 450 lbs, a 4-man lift) and cube by 96% (2.1 vs. 60.2 ft3), and virtually eliminates the difficult challenges in forward deployments of repairs and maintaining reliable operation, lifting and transporting, and electrical power required for steam autoclaves. PMID:24998679

  14. Reducing Risk of Salmonellosis through Egg Decontamination Processes.

    PubMed

    Keerthirathne, Thilini Piushani; Ross, Kirstin; Fallowfield, Howard; Whiley, Harriet

    2017-03-22

    Eggs have a high nutritional value and are an important ingredient in many food products. Worldwide foodborne illnesses, such as salmonellosis linked to the consumption of eggs and raw egg products, are a major public health concern. This review focuses on previous studies that have investigated the procedures for the production of microbiologically safe eggs. Studies exploring pasteurization and decontamination methods were investigated. Gamma irradiation, freeze drying, hot air, hot water, infra-red, atmospheric steam, microwave heating and radiofrequency heating are all different decontamination methods currently considered for the production of microbiologically safe eggs. However, each decontamination procedure has different effects on the properties and constituents of the egg. The pasteurization processes are the most widely used and best understood; however, they influence the coagulation, foaming and emulsifying properties of the egg. Future studies are needed to explore combinations of different decontamination methods to produce safe eggs without impacting the protein structure and usability. Currently, eggs which have undergone decontamination processes are primarily used in food prepared for vulnerable populations. However, the development of a decontamination method that does not affect egg properties and functionality could be used in food prepared for the general population to provide greater public health protection.

  15. Reducing Risk of Salmonellosis through Egg Decontamination Processes

    PubMed Central

    Keerthirathne, Thilini Piushani; Ross, Kirstin; Fallowfield, Howard; Whiley, Harriet

    2017-01-01

    Eggs have a high nutritional value and are an important ingredient in many food products. Worldwide foodborne illnesses, such as salmonellosis linked to the consumption of eggs and raw egg products, are a major public health concern. This review focuses on previous studies that have investigated the procedures for the production of microbiologically safe eggs. Studies exploring pasteurization and decontamination methods were investigated. Gamma irradiation, freeze drying, hot air, hot water, infra-red, atmospheric steam, microwave heating and radiofrequency heating are all different decontamination methods currently considered for the production of microbiologically safe eggs. However, each decontamination procedure has different effects on the properties and constituents of the egg. The pasteurization processes are the most widely used and best understood; however, they influence the coagulation, foaming and emulsifying properties of the egg. Future studies are needed to explore combinations of different decontamination methods to produce safe eggs without impacting the protein structure and usability. Currently, eggs which have undergone decontamination processes are primarily used in food prepared for vulnerable populations. However, the development of a decontamination method that does not affect egg properties and functionality could be used in food prepared for the general population to provide greater public health protection. PMID:28327524

  16. Ultraviolet light-an FDA approved technology

    USDA-ARS?s Scientific Manuscript database

    Ultraviolet Light (254 nm) is a U.S. Food and Drug Administration approved nonthermal intervention technology that can be used for decontamination of food and food contact surfaces. Ultraviolet light is a green technology that leaves no chemical residues. Results from our laboratory indicate that ex...

  17. Overview of Remote Handling Equipment Used for the NPP A1 Decommissioning - 12141

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kravarik, K.; Medved, J.; Pekar, A.

    The first Czechoslovak NPP A1 was in operation from 1972 to 1977 and it was finally shutdown due to an accident (level 4 according to the INES). The presence of radioactive, toxic or hazardous materials limits personnel access to facilities and therefore it is necessary to use remote handling technologies for some most difficult characterization, retrieval, decontamination and dismantling tasks. The history of remote handling technologies utilization started in nineties when the spent nuclear fuel, including those fuel assemblies damaged during the accident, was prepared for the transport to Russia. Subsequent significant development of remote handling equipment continued during implementationmore » of the NPP A1 decommissioning project - Stage I and ongoing Stage II. Company VUJE, Inc. is the general contractor for both mentioned stages of the decommissioning project. Various remote handling manipulators and robotics arms were developed and used. It includes remotely controlled vehicle manipulator MT-15 used for characterisation tasks in hostile and radioactive environment, special robust manipulator DENAR-41 used for the decontamination of underground storage tanks and multi-purposes robotics arms MT-80 and MT-80A developed for variety of decontamination and dismantling tasks. The heavy water evaporator facility dismantling is the current task performed remotely by robotics arm MT-80. The heavy water evaporator is located inside the main production building in the room No. 220 where loose surface contamination varies from 10 Bq/cm{sup 2} to 1x10{sup 3} Bq/cm{sup 2}, dose rate is up to 1.5 mGy/h and the feeding pipeline contained liquid RAW with high tritium content. Presented manipulators have been designed for broad range of decommissioning tasks. They are used for recognition, sampling, waste retrieval from large underground tanks, decontamination and dismantling of technological equipments. Each of the mentioned fields claims specific requirements on design of manipulator, their operation and control systems as well as tools of manipulators. Precise planning of decontamination and dismantling tasks is necessary for its successful performance by remotely controlled manipulator. The example of the heavy water evaporator demonstrates typical procedure for decommissioning of contaminated technological equipment by remotely controlled manipulators - planning of decommissioning tasks, preparatory tasks, modification of applied tools and design of specific supporting constructions for manipulator and finally decontamination and dismantling themselves. Due to the particularly demanding conditions in highly contaminated A1 NPP, a team of experts with special know-how in the field of decommissioning has grown up, and unique technological equipment enabling effective and safe work in environment with a high radiation level has been developed. (authors)« less

  18. Decontamination Efficacy of Three Commercial-Off-The-Shelf (COTS) Sporicidal Disinfectants on Medium-Sized Panels Contaminated with Surrogate Spores of Bacillus anthracis

    PubMed Central

    Sabol, Jonathan P.

    2014-01-01

    In the event of a wide area release and contamination of a biological agent in an outdoor environment and to building exteriors, decontamination is likely to consume the Nation’s remediation capacity, requiring years to cleanup, and leading to incalculable economic losses. This is in part due to scant body of efficacy data on surface areas larger than those studied in a typical laboratory (5×10-cm), resulting in low confidence for operational considerations in sampling and quantitative measurements of prospective technologies recruited in effective cleanup and restoration response. In addition to well-documented fumigation-based cleanup efforts, agencies responsible for mitigation of contaminated sites are exploring alternative methods for decontamination including combinations of disposal of contaminated items, source reduction by vacuuming, mechanical scrubbing, and low-technology alternatives such as pH-adjusted bleach pressure wash. If proven effective, a pressure wash-based removal of Bacillus anthracis spores from building surfaces with readily available equipment will significantly increase the readiness of Federal agencies to meet the daunting challenge of restoration and cleanup effort following a wide-area biological release. In this inter-agency study, the efficacy of commercial-of-the-shelf sporicidal disinfectants applied using backpack sprayers was evaluated in decontamination of spores on the surfaces of medium-sized (∼1.2 m2) panels of steel, pressure-treated (PT) lumber, and brick veneer. Of the three disinfectants, pH-amended bleach, Peridox, and CASCAD evaluated; CASCAD was found to be the most effective in decontamination of spores from all three panel surface types. PMID:24940605

  19. Plasma Decontamination: A Case Study on Kill Efficacy of Geobacillus stearothermophilus Spores on Different Carrier Materials.

    PubMed

    Semmler, Egmont; Novak, Wenzel; Allinson, Wilf; Wallis, Darren; Wood, Nigel; Awakowicz, Peter; Wunderlich, Joachim

    2016-01-01

    A new technology to the pharmaceutical field is presented: surface decontamination by plasmas The technology is comparable to established barrier systems like e-beam, volatile hydrogen peroxide, or radiation inactivation of microbiological contaminations. This plasma technology is part of a fully automated and validated syringe filling line at a major pharmaceutical company and is in production operation. Incoming pre-sterilized syringe containers ("tubs") are processed by plasma, solely on the outside, and passed into the aseptic filling isolator upon successful decontamination. The objective of this article is to present the operating principles and develop and establish a validation routine on the basis of standard commercial biological indicators. Their decontamination efficacies are determined and correlated to the actual inactivation efficacy on the pharmaceutical packaging material.The reference setup is explained in detail and a short presentation of the cycle development and the relevant plasma control parameters is given, with a special focus on the in-process monitor determining the cycle validity. Different microbial inactivation mechanisms are also discussed and evaluated for their contribution and interaction to enhance plasma decontamination. A material-dependent inactivation behavior was observed. In order to be able to correlate the tub surface inactivation of Geobacillus stearothermophilus endospores to metallic biological indicators, a comparative study was performed. Through consistently demonstrating the linear inactivation behavior between the different materials, it becomes possible to develop an effective and time-saving validation scheme. The challenge in new decontamination systems lies in a thorough validation of the inactivation efficacy under different operating regimes. With plasma, as an ionized gas, a new barrier concept is introduced into pharmaceutical aseptic processing of syringes. The presented system operates in vacuum and only decontaminates the outer surface of pre-sterilized syringe containers ("tubs"), before they are transferred into the aseptic area. The plasma does not penetrate into the tub. This article discusses the phase from development and test germ selection, across the identified sporicidal mechanisms, to a proposal for a validation scheme on the basis of commercially available biological indicators. A special focus is placed on an extensive investigation to establish a link between the tub surface microbial kill (polystyrene and Tyvek(and (2)) ) and biological indicator inactivation (stainless steel). Additionally, a rationale is developed on how an optical in-process monitor can be applied to establish a validatable limit on the base of the predetermined inactivation data of Geobacillus stearothermophilus endospores. © PDA, Inc. 2016.

  20. Use of cationic polymers to reduce pathogen levels during dairy manure separation.

    PubMed

    Liu, Zong; Carroll, Zachary S; Long, Sharon C; Gunasekaran, Sundaram; Runge, Troy

    2016-01-15

    Various separation technologies are used to deal with the enormous amounts of animal waste that large livestock operations generate. When the recycled waste stream is land applied, it is essential to lower the pathogen load to safeguard the health of livestock and humans. We investigated whether cationic polymers, used as a flocculent in the solid/liquid separation process, could reduce the pathogen indicator load in the animal waste stream. The effects of low charge density cationic polyacrylamide (CPAM) and high charge density cationic polydicyandiamide (PDCD) were investigated. Results demonstrated that CPAM was more effective than PDCD for manure coagulation and flocculation, while PDCD was more effective than CPAM in reducing the pathogen indicator loads. However, their combined use, CPAM followed by PDCD, resulted in both improved solids separation and pathogen indicator reduction. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  1. Improving the Accuracy of Coastal Sea Surface Heights by Retracking Decontaminated Radar Altimetry Waveforms

    NASA Astrophysics Data System (ADS)

    Huang, Zhengkai; Wang, Haihong; Luo, Zhicai

    2017-04-01

    Due to the complex coastal topography and energetic ocean dynamics effect, the return echoes are contaminated while the satellite footprint approaches or leaves the coastline. Specular peaks are often induced in the trailing edges of contaminated waveforms, thus leading the error in the determination of the leading edge and associated track offset in the waveform retracking process. We propose an improved algorithm base on Tseng's modification method to decontaminated coastal (0-7 km from coastline) waveforms, thus improving both the utilization and precision of coastal sea surface height (SSH). Using the Envisat/Jason-2 SGDR data, the shortcoming of Tseng's method is pointed out and the novel algorithm is proposed by revising the strategy of selecting reference waveform and determining weight for removing outlier. The reference waveform of the decontaminated technology is closer to the real waveform of the offshore area, which avoids the over-modification problem of Tseng method. The sea-level measurements from tide gauge station and geoid height from EGM2008 model were used to validate the retracking strategy. Experimental results show that decontaminated waveform was more suitable than original and Tseng modified waveform and has uniform performance in both compare to the tide gauge and geoid. The retrieved altimetry data in the 0-1km and 1-7km coastal zone indicate that threshold retracker with decontaminated waveform have STD of 73.8cm and 33cm as compared with in situ gauge data,which correspond to 62.1% and 58% in precession compared to the unretracked altimetry measurements. The retracked SSHs are better in two coastal (0-1 km and 1-7km) zones, which have STD of 11.9cm and 22.7cm as compared with geoid height. Furthermore, the comparisons shows that the precision of decontaminated technology improve 0.3cm and 3.3cm than the best result of PISTACH product in coastal sea. This work is supported by the National Natural Science Foundation of China (Grant Nos. 41174020, 41174021, 41131067) and the open fund of Guangxi Key Laboratory of Spatial Information and Geometrics (Grant No. 15-140-07-26). Index Terms: retracking, Envisat, Jason-2, Coastal sea, decontamination.

  2. Biocontrol activity of four non- and low-fermenting yeast strains against Aspergillus carbonarius and their ability to remove ochratoxin A from grape juice.

    PubMed

    Fiori, Stefano; Urgeghe, Pietro Paolo; Hammami, Walid; Razzu, Salvatorico; Jaoua, Samir; Migheli, Quirico

    2014-10-17

    Aspergillus spp. infection of grape may lead to ochratoxin A (OTA) contamination in processed beverages such as wine and grape juice. The aim of the current study was to evaluate the biocontrol potential of two non-fermenting (Cyberlindnera jadinii 273 and Candida friedrichii 778) and two low-fermenting (Candida intermedia 235 and Lachancea thermotolerans 751) yeast strains against the pathogenic fungus and OTA-producer Aspergillus carbonarius, and their ability to remove OTA from grape juice. Two strains, 235 and 751, showed a significant ability to inhibit A. carbonarius both on grape berries and in in vitro experiments. Neither their filtrate nor their autoclaved filtrate culture broth was able to prevent consistently pathogen growth. Volatile organic compounds (VOCs) produced by all four selected yeasts were likely able to consistently prevent pathogen sporulation in vitro. VOCs produced by the non-fermenting strain 778 also significantly reduced A. carbonarius vegetative growth. Three yeast strains (235, 751, and 778) efficiently adsorbed artificially spiked OTA from grape juice, while autoclaving treatment improved OTA adsorption capacity by all the four tested strains. Biological control of A. carbonarius and OTA-decontamination using yeast is proposed as an approach to meet the Islamic dietary laws concerning the absence of alcohol in halal beverages. Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.

  3. Reducing persistent organic pollutants while maintaining long chain omega-3 fatty acid in farmed Atlantic salmon using decontaminated fish oils for an entire production cycle.

    PubMed

    Berntssen, M H G; Olsvik, P A; Torstensen, B E; Julshamn, K; Midtun, T; Goksøyr, A; Johansen, J; Sigholt, T; Joerum, N; Jakobsen, J-V; Lundebye, A-K; Lock, E-J

    2010-09-01

    Oily fish are an important source of health promoting nutrients such as the very long chain marine omega-3 (VLC-n3) fatty acids and simultaneously a source of potentially hazardous contaminants. Fish oils that are used in fish feed are the main source for both contaminants and VLC-n3. Decontamination techniques have recently been developed to effectively remove persistent organic contaminants from fish oils. The aim of the present study was to assess the level of potentially hazardous contaminants and the health beneficial fatty acids in Atlantic salmon reared on novel decontaminated feeds. Atlantic salmon were fed for 18 months (an entire seawater production cycle) on diets based on decontaminated or non-treated (control) fish oils until market size (approximately 5 kg). The level of known notorious persistent organic pollutants (POPs, i.e. dioxins, dioxin-like polychlorinated biphenyls (DL-PCBs), non dioxin-like PCBs, poly brominated diphenyl ethers (PBDE), and organochlorine pesticides), as well as fatty acid composition were analysed in fish oils, the two diets, and Atlantic salmon fillet. The oil decontamination process was a two-step procedure using active carbon and short path distillation. The fillet levels of POPs in market size fish were reduced by 68-85% while the concentration of very long chain omega-3 fatty acids was reduced by 4-7%. No differences in biomarkers of dioxin-like component exposures, such as hepatic gene expression of CYP1A or AhR2B, CYP1A protein expression and 7-ethoxyresorufin O-deethylase (EROD) activity, were observed between salmon raised on normal or decontaminated feeds, thus indicating that the difference in POPs levels were of no biological significance to the fish. Atlantic salmon reared on decontaminated feeds had sum polychlorinated dibenzodioxins/furans (PCDD/Fs) and DL-PCB concentrations that were comparable with terrestrial food products such as beef, while the level of marine omega-3 fatty acids remained as high as for commercially farmed Atlantic salmon. (c) 2010 Elsevier Ltd. All rights reserved.

  4. Antibacterial Activity of Blue Light against Nosocomial Wound Pathogens Growing Planktonically and as Mature Biofilms.

    PubMed

    Halstead, Fenella D; Thwaite, Joanne E; Burt, Rebecca; Laws, Thomas R; Raguse, Marina; Moeller, Ralf; Webber, Mark A; Oppenheim, Beryl A

    2016-07-01

    The blue wavelengths within the visible light spectrum are intrinisically antimicrobial and can photodynamically inactivate the cells of a wide spectrum of bacteria (Gram positive and negative) and fungi. Furthermore, blue light is equally effective against both drug-sensitive and -resistant members of target species and is less detrimental to mammalian cells than is UV radiation. Blue light is currently used for treating acnes vulgaris and Helicobacter pylori infections; the utility for decontamination and treatment of wound infections is in its infancy. Furthermore, limited studies have been performed on bacterial biofilms, the key growth mode of bacteria involved in clinical infections. Here we report the findings of a multicenter in vitro study performed to assess the antimicrobial activity of 400-nm blue light against bacteria in both planktonic and biofilm growth modes. Blue light was tested against a panel of 34 bacterial isolates (clinical and type strains) comprising Acinetobacter baumannii, Enterobacter cloacae, Stenotrophomonas maltophilia, Pseudomonas aeruginosa, Escherichia coli, Staphylococcus aureus, Enterococcus faecium, Klebsiella pneumoniae, and Elizabethkingia meningoseptica All planktonic-phase bacteria were susceptible to blue light treatment, with the majority (71%) demonstrating a ≥5-log10 decrease in viability after 15 to 30 min of exposure (54 J/cm(2) to 108 J/cm(2)). Bacterial biofilms were also highly susceptible to blue light, with significant reduction in seeding observed for all isolates at all levels of exposure. These results warrant further investigation of blue light as a novel decontamination strategy for the nosocomial environment, as well as additional wider decontamination applications. Blue light shows great promise as a novel decontamination strategy for the nosocomial environment, as well as additional wider decontamination applications (e.g., wound closure during surgery). This warrants further investigation. © Crown copyright 2016.

  5. Antibacterial Activity of Blue Light against Nosocomial Wound Pathogens Growing Planktonically and as Mature Biofilms

    PubMed Central

    Thwaite, Joanne E.; Burt, Rebecca; Laws, Thomas R.; Raguse, Marina; Moeller, Ralf; Webber, Mark A.; Oppenheim, Beryl A.

    2016-01-01

    ABSTRACT The blue wavelengths within the visible light spectrum are intrinisically antimicrobial and can photodynamically inactivate the cells of a wide spectrum of bacteria (Gram positive and negative) and fungi. Furthermore, blue light is equally effective against both drug-sensitive and -resistant members of target species and is less detrimental to mammalian cells than is UV radiation. Blue light is currently used for treating acnes vulgaris and Helicobacter pylori infections; the utility for decontamination and treatment of wound infections is in its infancy. Furthermore, limited studies have been performed on bacterial biofilms, the key growth mode of bacteria involved in clinical infections. Here we report the findings of a multicenter in vitro study performed to assess the antimicrobial activity of 400-nm blue light against bacteria in both planktonic and biofilm growth modes. Blue light was tested against a panel of 34 bacterial isolates (clinical and type strains) comprising Acinetobacter baumannii, Enterobacter cloacae, Stenotrophomonas maltophilia, Pseudomonas aeruginosa, Escherichia coli, Staphylococcus aureus, Enterococcus faecium, Klebsiella pneumoniae, and Elizabethkingia meningoseptica. All planktonic-phase bacteria were susceptible to blue light treatment, with the majority (71%) demonstrating a ≥5-log10 decrease in viability after 15 to 30 min of exposure (54 J/cm2 to 108 J/cm2). Bacterial biofilms were also highly susceptible to blue light, with significant reduction in seeding observed for all isolates at all levels of exposure. These results warrant further investigation of blue light as a novel decontamination strategy for the nosocomial environment, as well as additional wider decontamination applications. IMPORTANCE Blue light shows great promise as a novel decontamination strategy for the nosocomial environment, as well as additional wider decontamination applications (e.g., wound closure during surgery). This warrants further investigation. PMID:27129967

  6. Lightweight Portable Plasma Medical Device - Plasma Engineering Research Laboratory

    DTIC Science & Technology

    2012-10-01

    cut fruit surfaces contaminated with migrating microorganisms," Journal of Food Protection, vol. 71, pp. 1619-1625, Aug 2008. [31] H. L. Chen, et...foodborne and opportunistic nosocomial pathogens is a major problem in food industry, biomedical and hospital applications, respectively. The resistive...source is very efficient in decontaminating wide range of infection and contamination causing bacteria. The direct and indirect exposure of the RBP

  7. Planning guidance for nuclear-power-plant decontamination. [PWR; BWR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Munson, L.F.; Divine, J.R.; Martin, J.B.

    1983-06-01

    Direct and indirect costs of decontamination are considered in the benefit-cost analysis. A generic form of the benefit-cost ratio is evaluated in monetary and nonmonetary terms, and values of dollar per man-rem are cited. Federal and state agencies that may have jurisiction over various aspects of decontamination and waste disposal activities are identified. Methods of decontamination, their general effectiveness, and the advantages and disadvantages of each are outlined. Dilute or concentrated chemical solutions are usually used in-situ to dissolve the contamination layer and a thin layer of the underlying substrate. Electrochemical techniques are generally limited to components but show highmore » decontamination effectiveness with uniform corrosion. Mechanical agents are particularly appropriate for certain out-of-system surfaces and disassembled parts. These processes are catagorized and specific concerns are discussed. The treatment, storage, and disposal or discharge or discharge of liquid, gaseous, and solid wastes generated during the decontamination process are discussed. Radioactive and other hazardous chemical wastes are considered. The monitoring, treatment, and control of radioactive and nonradioactive effluents, from both routine operations and possible accidents, are discussed. Protecting the health and safety of personnel onsite during decontamination is of prime importance and should be considered in each facet of the decontamination process. The radiation protection philosophy of reducing exposure to levels as low as reasonably achievable should be stressed. These issues are discussed.« less

  8. Compressed sodium chloride as a fast-acting antimicrobial surface: results of a pilot study.

    PubMed

    Whitlock, B D; Smith, S W

    2016-10-01

    Antimicrobial surfaces are currently being studied as an aid to reduce transmission of pathogens leading to healthcare-associated infections (HAIs). Among the most harmful and costly pathogens that cause HAIs is meticillin-resistant Staphylococcus aureus (MRSA). Currently available and previously investigated antimicrobial surface technologies that are effective against MRSA (e.g. copper alloy surfaces) take 30min to several hours to achieve significant reduction. This article presents a new antimicrobial surface technology made of compressed sodium chloride that reduces MRSA 20-30 times faster than copper alloy surfaces. Copyright © 2016 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  9. Hairy skin exposure to VX in vitro: effectiveness of delayed decontamination.

    PubMed

    Rolland, P; Bolzinger, M-A; Cruz, C; Josse, D; Briançon, S

    2013-02-01

    The chemical warfare agents such as VX represent a threat for both military and civilians, which involves an immediate need of effective decontamination systems. Since human scalp is usually unprotected compared to other body regions covered with clothes, it could be a preferential site of exposure in case of terrorist acts. The purpose of this study was to determine if skin decontamination could be efficient when performed more than 1h after exposure. In addition, the impact of hairs in skin contamination was investigated. By using in vitro skin models, we demonstrated that about 75% of the applied quantity of VX was recovered on the skin surface 2h after skin exposition, which means that it is worth decontaminating even if contamination occurred 2h before. The stratum corneum reservoir for VX was quickly established and persistent. In addition, the presence of hairs modified the percutaneous penetration of the nerve agent by binding of VX to hairs. Hair shaft has thus to be taken into account in the decontamination process. Reactive Skin Decontamination Lotion (RSDL) and Fuller's Earth (FE) were active in the skin decontamination 45min post-exposure, but RSDL was more efficient in reducing the amount of VX either in the skin or in the hair. Copyright © 2012 Elsevier Ltd. All rights reserved.

  10. Decontamination of prions in a plasma product manufacturing environment.

    PubMed

    Bellon, Anne; Comoy, Emmanuel; Simoneau, Steve; Mornac, Sandrine; Dehen, Capucine; Perrin, Audrey; Arzel, Aude; Arrabal, Samuel; Baron, Henry; Laude, Hubert; You, Bruno; Deslys, Jean-Philippe; Flan, Benoit

    2014-04-01

    The high resistance of prions to inactivating treatments requires the proper management of decontaminating procedures of equipment in contact with materials of human or animal origin destined for medical purposes. Sodium hydroxide (NaOH) is widely used today for this purpose as it inactivates a wide variety of pathogens including prions. Several NaOH treatments were tested on prions bound to either stainless steel or chromatographic resins in industrial conditions with multiple prion strains. Data show a strong correlation between inactivation results obtained by immunochemical detection of the prion protein and those obtained with infectivity assays and establish effective inactivation treatments for prions bound to stainless steel or chromatographic resins (ion exchange and affinity), including treatments with lower NaOH concentrations. Furthermore, no obvious strain-specific behavior difference was observed between experimental models. The results generated by these investigations show that industrial NaOH decontamination regimens (in combination with the NaCl elution in the case of the chromatography process) attain substantial prion inactivation and/or removal between batches, thus providing added assurance to the biologic safety of the final plasma-derived medicinal products. © 2013 American Association of Blood Banks.

  11. New information technology tools for a medical command system for mass decontamination.

    PubMed

    Fuse, Akira; Okumura, Tetsu; Hagiwara, Jun; Tanabe, Tomohide; Fukuda, Reo; Masuno, Tomohiko; Mimura, Seiji; Yamamoto, Kaname; Yokota, Hiroyuki

    2013-06-01

    In a mass decontamination during a nuclear, biological, or chemical (NBC) response, the capability to command, control, and communicate is crucial for the proper flow of casualties at the scene and their subsequent evacuation to definitive medical facilities. Information Technology (IT) tools can be used to strengthen medical control, command, and communication during such a response. Novel IT tools comprise a vehicle-based, remote video camera and communication network systems. During an on-site verification event, an image from a remote video camera system attached to the personal protective garment of a medical responder working in the warm zone was transmitted to the on-site Medical Commander for aid in decision making. Similarly, a communication network system was used for personnel at the following points: (1) the on-site Medical Headquarters; (2) the decontamination hot zone; (3) an on-site coordination office; and (4) a remote medical headquarters of a local government office. A specially equipped, dedicated vehicle was used for the on-site medical headquarters, and facilitated the coordination with other agencies. The use of these IT tools proved effective in assisting with the medical command and control of medical resources and patient transport decisions during a mass-decontamination exercise, but improvements are required to overcome transmission delays and camera direction settings, as well as network limitations in certain areas.

  12. Non-thermal plasma technologies: new tools for bio-decontamination.

    PubMed

    Moreau, M; Orange, N; Feuilloley, M G J

    2008-01-01

    Bacterial control and decontamination are crucial to industrial safety assessments. However, most recently developed materials are not compatible with standard heat sterilization treatments. Advanced oxidation processes, and particularly non-thermal plasmas, are emerging and promising technologies for sanitation because they are both efficient and cheap. The applications of non-thermal plasma to bacterial control remain poorly known for several reasons: this technique was not developed for biological applications and most of the literature is in the fields of physics and chemistry. Moreover, the diversity of the devices and complexity of the plasmas made any general evaluation of the potential of the technique difficult. Finally, no experimental equipment for non-thermal plasma sterilization is commercially available and reference articles for microbiologists are rare. The present review aims to give an overview of the principles of action and applications of plasma technologies in biodecontamination.

  13. Water chemistry control and decontamination experience with TEPCO BWR`s and the measures planned for the future

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Suzuki, N.; Miyamaru, K.

    1995-03-01

    The new TEPCO BWR`s are capable of having the occupational radiation exposure controlled successfully at a low level by selecting low cobalt steel, using corrosion-resistant steel, employing dual condensate polishing systems, and controlling Ni/Fe ratio during operation. The occupational radiation exposure of the old BWR`s, on the other hand, remains high though reduced substantially through the use of low cobalt replacement steel and the partial addition of a filter in the condensate polishing system. Currently under review is the overall decontamination procedure for the old BWR`s to find out to measures needed to reduce the amount of crud that ismore » and has been carried over into the nuclear reactor. The current status of decontamination is reported below.« less

  14. Development and field testing of a mobile chlorine dioxide generation system for the decontamination of buildings contaminated with Bacillus anthracis.

    PubMed

    Wood, Joseph P; Blair Martin, G

    2009-05-30

    The numerous buildings that became contaminated with Bacillus anthracis (the bacterium causing the disease anthrax) in 2001, and more recent B. anthracis - related events, point to the need to have effective decontamination technologies for buildings contaminated with biological threat agents. The U.S. Government developed a portable chlorine dioxide (ClO(2)) generation system to decontaminate buildings contaminated with B. anthracis spores, and this so-called mobile decontamination trailer (MDT) prototype was tested through a series of three field trials. The first test of the MDT was conducted at Fort McClellan in Anniston, AL. during October 2004. Four test attempts occurred over two weekends; however, a number of system problems resulted in termination of the activity prior to any ClO(2) introduction into the test building. After making several design enhancements and equipment changes, the MDT was subjected to a second test. During this test, extensive leak checks were made using argon and nitrogen in lieu of chlorine gas; each subsystem was checked for functionality, and the MDT was operated for 24h. This second test demonstrated the MDT flow and control systems functioned satisfactorily, and thus it was decided to proceed to a third, more challenging field trial. In the last field test, ClO(2) was generated and routed directly to the scrubber in a 12-h continuous run. Measurement of ClO(2) levels at the generator outlet showed that the desired production rate was not achieved. Additionally, only one of the two scrubbers performed adequately with regard to maintaining ClO(2) emissions below the limit. Numerous lessons were learned in the field trials of this ClO(2) decontamination technology.

  15. Comparison of eggshell surface sanitization technologies and impacts on consumer acceptability.

    PubMed

    Al-Ajeeli, Morouj N; Taylor, T Matthew; Alvarado, Christine Z; Coufal, Craig D

    2016-05-01

    Shell eggs can be contaminated with many types of microorganisms, including bacterial pathogens, and thus present a risk for the transmission of foodborne disease to consumers. Currently, most United States egg processors utilize egg washing and sanitization systems to decontaminate surfaces of shell eggs prior to packaging. However, previous research has indicated that current shell egg sanitization technologies employed in the commercial egg industry may not completely eliminate bacteria from the surface of eggshells, and thus alternative egg sanitization technologies with the potential for increased microbial reductions on eggshells should be investigated. The objectives of this study were to compare the antimicrobial efficacy and consumer sensory attributes of industry-available eggshell sanitization methods (chlorine and quaternary ammonium compounds (QAC) applied via spray) to various alternative egg sanitization technologies. Eggs (White Leghorn hens; n=195) were obtained for evaluation of sanitizer-induced reduction in mesophilic aerobic bacteria (n=90) or inoculated Salmonella Enteritidis (SE) reduction (n=105). Sanitizing treatments evaluated in this experiment were: chlorine spray (100 ppm available chlorine), QAC spray (200 ppm), peracetic acid spray (PAA; 135 ppm) alone or in combination with ultraviolet light (UV; 254 nm), and hydrogen peroxide (H2O2; 3.5% solution) spray in combination with UV (H2O2+UV). For enumeration of aerobic bacteria, eggs were sampled at 0, 7, and 14 days of storage at 4°C; surviving SE cells from inoculated eggs were enumerated by differential plating. Sensory trials were conducted to determine consumer liking of scrambled eggs made from eggs sanitized with chlorine, QAC, H2O2+UV, or no treatment (control). The H2O2 and UV treatment resulted in the greatest reductions in eggshell aerobic plate counts compared to other treatments throughout egg storage (P<0.05). All treatments utilized reduced SE below the limit of detection by eggshell rinse. There were no differences in consumers' liking of overall flavor between the 4 treatments evaluated. The application of H2O2+UV treatment to shell eggs represents a novel technology that could have important implications for egg quality and safety preservation. © 2016 Poultry Science Association Inc.

  16. Drying parameters greatly affect the destruction of Cronobacter sakazakii and Salmonella Typhimurium in standard buffer and milk.

    PubMed

    Lang, Emilie; Iaconelli, Cyril; Zoz, Fiona; Guyot, Stéphane; Alvarez-Martin, Pablo; Beney, Laurent; Perrier-Cornet, Jean-Marie; Gervais, Patrick

    2017-04-01

    Salmonella Typhimurium and Cronobacter sakazakii are two foodborne pathogens involved in neonatal infections from milk powder and infant formula. Their ability to survive in low-moisture food and during processing from the decontamination to the dried state is a major issue in food protection. In this work, we studied the effects of the drying process on Salmonella Typhimurium and Cronobacter sakazakii, with the aim of identifying the drying parameters that could promote greater inactivation of these two foodborne pathogens. These two bacteria were dried under different atmospheric relative humidities in milk and phosphate-buffered saline, and the delays in growth recovery and cultivability were followed. We found that water activity was related to microorganism resistance. C. sakazakii was more resistant to drying than was S. Typhimurium, and milk increased the cultivability and recovery of these two species. High drying rates and low final water activity levels (0.11-0.58) had a strong negative effect on the growth recovery and cultivability of these species. In conclusion, we suggest that effective use of drying processes may provide a complementary tool for food decontamination and food safety during the production of low-moisture foods. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Prevention of nosocomial infection in cardiac surgery by decontamination of the nasopharynx and oropharynx with chlorhexidine gluconate: a randomized controlled trial.

    PubMed

    Segers, Patrique; Speekenbrink, Ron G H; Ubbink, Dirk T; van Ogtrop, Marc L; de Mol, Bas A

    2006-11-22

    Nosocomial infections are an important cause of morbidity and mortality after cardiac surgery. Decolonization of endogenous potential pathogenic microorganisms is important in the prevention of nosocomial infections. To determine the efficacy of perioperative decontamination of the nasopharynx and oropharynx with 0.12% chlorhexidine gluconate for reduction of nosocomial infection after cardiac surgery. A prospective, randomized, double-blind, placebo-controlled clinical trial conducted at the Onze Lieve Vrouwe Gasthuis, Amsterdam, the Netherlands, between August 1, 2003, and September 1, 2005. Of 991 patients older than 18 years undergoing elective cardiothoracic surgery during the study interval, 954 were eligible for analysis. Oropharyngeal rinse and nasal ointment containing either chlorhexidine gluconate or placebo. Incidence of nosocomial infection, in addition to the rate of Staphylococcus aureus nasal carriage and duration of hospital stay. The incidence of nosocomial infection in the chlorhexidine gluconate group and placebo group was 19.8% and 26.2%, respectively (absolute risk reduction [ARR], 6.4%; 95% confidence interval [CI], 1.1%-11.7%; P = .002). In particular, lower respiratory tract infections and deep surgical site infections were less common in the chlorhexidine gluconate group than in the placebo group (ARR, 6.5%; 95% CI, 2.3%-10.7%; P = .002; and 3.2%; 95% CI, 0.9%-5.5%; P = .002, respectively). For the prevention of 1 nosocomial infection, 16 patients needed to be treated with chlorhexidine gluconate. A significant reduction of 57.5% in S aureus nasal carriage was found in the chlorhexidine gluconate group compared with a reduction of 18.1% in the placebo group (P<.001). Total hospital stay for patients treated with chlorhexidine gluconate was 9.5 days compared with 10.3 days in the placebo group (ARR, 0.8 days; 95% CI, 0.24-1.88; P = .04). Decontamination of the nasopharynx and oropharynx with chlorhexidine gluconate appears to be an effective method to reduce nosocomial infection after cardiac surgery. clinicaltrials.gov Identifier: NCT00272675.

  18. Decolonization in Prevention of Health Care-Associated Infections

    PubMed Central

    Schweizer, Marin L.

    2016-01-01

    SUMMARY Colonization with health care-associated pathogens such as Staphylococcus aureus, enterococci, Gram-negative organisms, and Clostridium difficile is associated with increased risk of infection. Decolonization is an evidence-based intervention that can be used to prevent health care-associated infections (HAIs). This review evaluates agents used for nasal topical decolonization, topical (e.g., skin) decolonization, oral decolonization, and selective digestive or oropharyngeal decontamination. Although the majority of studies performed to date have focused on S. aureus decolonization, there is increasing interest in how to apply decolonization strategies to reduce infections due to Gram-negative organisms, especially those that are multidrug resistant. Nasal topical decolonization agents reviewed include mupirocin, bacitracin, retapamulin, povidone-iodine, alcohol-based nasal antiseptic, tea tree oil, photodynamic therapy, omiganan pentahydrochloride, and lysostaphin. Mupirocin is still the gold standard agent for S. aureus nasal decolonization, but there is concern about mupirocin resistance, and alternative agents are needed. Of the other nasal decolonization agents, large clinical trials are still needed to evaluate the effectiveness of retapamulin, povidone-iodine, alcohol-based nasal antiseptic, tea tree oil, omiganan pentahydrochloride, and lysostaphin. Given inferior outcomes and increased risk of allergic dermatitis, the use of bacitracin-containing compounds cannot be recommended as a decolonization strategy. Topical decolonization agents reviewed included chlorhexidine gluconate (CHG), hexachlorophane, povidone-iodine, triclosan, and sodium hypochlorite. Of these, CHG is the skin decolonization agent that has the strongest evidence base, and sodium hypochlorite can also be recommended. CHG is associated with prevention of infections due to Gram-positive and Gram-negative organisms as well as Candida. Conversely, triclosan use is discouraged, and topical decolonization with hexachlorophane and povidone-iodine cannot be recommended at this time. There is also evidence to support use of selective digestive decontamination and selective oropharyngeal decontamination, but additional studies are needed to assess resistance to these agents, especially selection for resistance among Gram-negative organisms. The strongest evidence for decolonization is for use among surgical patients as a strategy to prevent surgical site infections. PMID:26817630

  19. The theory and application of space microbiology: China's experiences in space experiments and beyond.

    PubMed

    Liu, Changting

    2017-02-01

    Microorganisms exhibit high adaptability to extreme environments of outer space via phenotypic and genetic changes. These changes may affect astronauts in the space environment as well as on Earth because mutant microbes will inevitably return with the spacecraft. However, the role and significance of these phenotypic changes and the underlying mechanisms are important unresolved questions in the field of space biology. By reviewing, especially the Chinese studies, we propose a space microbial molecular effect theory, that is, the space environment affects the nature of genes and the molecular structure of microorganisms to produce phenotypic changes. In this review, we discussed three basic theories for the research of space microbiology, including (1) space microbial pathogenicity and virulence mutations and the human mutualism theory; (2) space microbial drug-resistance mutations and metabolism associated with space pharmaceuticals theory; (3) space corrosion, microbial decontamination, and new materials technology theory. © 2016 Society for Applied Microbiology and John Wiley & Sons Ltd.

  20. Evidence-based patient decontamination: an integral component of mass exposure chemical incident planning and response.

    PubMed

    Leary, Adam D; Schwartz, Michael D; Kirk, Mark A; Ignacio, Joselito S; Wencil, Elaine B; Cibulsky, Susan M

    2014-06-01

    Decontaminating patients who have been exposed to hazardous chemicals can directly benefit the patients' health by saving lives and reducing the severity of toxicity. While the importance of decontaminating patients to prevent the spread of contamination has long been recognized, its role in improving patient health outcomes has not been as widely appreciated. Acute chemical toxicity may manifest rapidly-often minutes to hours after exposure. Patient decontamination and emergency medical treatment must be initiated as early as possible to terminate further exposure and treat the effects of the dose already absorbed. In a mass exposure chemical incident, responders and receivers are faced with the challenges of determining the type of care that each patient needs (including medical treatment, decontamination, and behavioral health support), providing that care within the effective window of time, and protecting themselves from harm. The US Department of Health and Human Services and Department of Homeland Security have led the development of national planning guidance for mass patient decontamination in a chemical incident to help local communities meet these multiple, time-sensitive health demands. This report summarizes the science on which the guidance is based and the principles that form the core of the updated approach.

  1. Composition of CBRN Decontamination Effluent and Development of Surrogate Mixtures for Testing Effluent Treatment Technologies

    DTIC Science & Technology

    2016-07-01

    possible, the site around the wash stations is graded to allow the wash water to run off to a pit, where it can seep into the earth or be collected...Caustic soda solution Radioisotopes /Nuclear Residuals Soap with warm water DS2 = Decontamination Solution 2 STB = Super Tropical bleach HTH = High... DATE (DD-MM-YYYY) 2. REPORT TYPE 3. DATES COVERED (From - To) 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER

  2. Catalytic Enzyme-Based Methods for Water Treatment and Water Distribution System Decontamination. 1. Literature Survey

    DTIC Science & Technology

    2006-06-01

    TREATMENT AND WATER DISTRIBUTION SYSTEM DECONTAMINATION 1 . LITERATURE SURVEY Joseph J. DeFrank RESEARCH AND TECHNOLOGY DIRECTORATE June 2006 Approved for...No. 0704-0188 Public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing...YOUR FORM TO THE ABOVE ADDRESS. 1 . REPORT DATE (DD-MM-YYYY) 2. REPORT TYPE 3. DATES COVERED (From - To) XX-06-2006 Literature Survey May 2004 - Aug 2004

  3. Assessing peracetic acid as a means to control post-vaccination Saprolegniasis in Atlantic salmon Salmo salar parr in recirculation aquaculture systems

    USDA-ARS?s Scientific Manuscript database

    Land-based closed containment facilities, utilizing recirculation aquaculture system (RAS) technologies, can reduce or eliminate the introduction of obligate fish pathogens. Regardless, the presence of opportunistic pathogens must be assumed, and these agents can cause disease during unfavorable con...

  4. Chapter 24. emerging technologies for irrigation water treatment

    USDA-ARS?s Scientific Manuscript database

    Several disinfestants that have potential for treating recycled irrigation water are less commonly used or newer developing technologies. Hydrogen peroxide can reduce spread of pathogens in water that contains nutrients or pesticide residues without generating toxic residues. Benefits potentially in...

  5. Frequency of Hand Decontamination of Intraoperative Providers and Reduction of Postoperative Healthcare-Associated Infections: A Randomized Clinical Trial of a Novel Hand Hygiene System.

    PubMed

    Koff, Matthew D; Brown, Jeremiah R; Marshall, Emily J; O'Malley, A James; Jensen, Jens T; Heard, Stephen O; Longtine, Karen; O'Neill, Melissa; Longtine, Jaclyn; Houston, Donna; Robison, Cindy; Moulton, Eric; Patel, Hetal M; Loftus, Randy W

    2016-08-01

    BACKGROUND Healthcare provider hands are an important source of intraoperative bacterial transmission events associated with postoperative infection development. OBJECTIVE To explore the efficacy of a novel hand hygiene improvement system leveraging provider proximity and individual and group performance feedback in reducing 30-day postoperative healthcare-associated infections via increased provider hourly hand decontamination events. DESIGN Randomized, prospective study. SETTING Dartmouth-Hitchcock Medical Center in New Hampshire and UMass Memorial Medical Center in Massachusetts. PATIENTS Patients undergoing surgery. METHODS Operating room environments were randomly assigned to usual intraoperative hand hygiene or to a personalized, body-worn hand hygiene system. Anesthesia and circulating nurse provider hourly hand decontamination events were continuously monitored and reported. All patients were followed prospectively for the development of 30-day postoperative healthcare-associated infections. RESULTS A total of 3,256 operating room environments and patients (1,620 control and 1,636 treatment) were enrolled. The mean (SD) provider hand decontamination event rate achieved was 4.3 (2.9) events per hour, an approximate 8-fold increase in hand decontamination events above that of conventional wall-mounted devices (0.57 events/hour); P<.001. Use of the hand hygiene system was not associated with a reduction in healthcare-associated infections (odds ratio, 1.07 [95% CI, 0.82-1.40], P=.626). CONCLUSIONS The hand hygiene system evaluated in this study increased the frequency of hand decontamination events without reducing 30-day postoperative healthcare-associated infections. Future work is indicated to optimize the efficacy of this hand hygiene improvement strategy. Infect Control Hosp Epidemiol 2016;37:888-895.

  6. Microbial flora on cell-phones in an orthopedic surgery room before and after decontamination.

    PubMed

    Murgier, J; Coste, J-F; Cavaignac, E; Bayle-Iniguez, X; Chiron, P; Bonnevialle, P; Laffosse, J-M

    2016-12-01

    Cell-phones are the typical kind of object brought into the operating room from outside by hospital staff. A great effort is made to reduce the level of potentially contaminating bacteria in the operating room, and introducing these devices may run counter to good practice. The study hypothesis was that cell-phones are colonized by several strains of bacteria and may constitute a source of nosocomial contamination. The main study objective was to screen for bacterial colonies on the surfaces of cell-phones introduced in an orthopedic surgery room. The secondary objective was to assess the efficacy of decontamination. Samples were taken from the cell-phones of hospital staff (surgeons, anaesthetists, nurses, radiology operators, and external medical representatives) entering the operating room of the university hospital center orthopedic surgery department, Toulouse (France). Sampling used Count Tact ® contact gel, without wiping the phone down in advance. Both sides of the phone were sampled, before and after decontamination with a pad imbibed with 0.25% Surfanios ® Premium disinfectant. A nasal sample was also taken to investigate the correlation between Staphylococcus aureus in the nasal cavities and on the cell-phone. Fifty-two cell-phones were sampled. Before decontamination, the mean number of colony-forming units (CFU) was 258 per phone (range, 0-1,664). After decontamination, it was 127 (range, 0-800) (P=0.0001). Forty-nine cell-phones bore CFUs before decontamination (94%), and 39 after (75%) (P=0.02). Cell-phones are CFU carriers and may thus lead to contamination. Guidelines should be drawn up to encourage cleaning phones regularly and to reduce levels of use within the operating room. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  7. Experimental assessment of disinfection procedures for eradication of Aspergillus fumigatus in food.

    PubMed

    Gangneux, Jean-Pierre; Noussair, Latifa; Bouakline, Adel; Roux, Nicole; Lacroix, Claire; Derouin, Francis

    2004-10-01

    Aspergillus fumigatus spores in food may represent an infectious risk for neutropenic patients. We examined the efficiency of disinfection procedures applicable to foods for eradication of A fumigatus. Boiling and microwave treatment fully decontaminated an experimental spore suspension and naturally contaminated liquid foods (reconstituted dried food, herbal tea). Full decontamination of experimentally contaminated surfaces was only obtained with 70% ethanol or heating at 220 degrees C for 15 minutes. Pepper was decontaminated when heated for 15 minutes at 220 degrees C but not by microwaving. Fruit skin was partially decontaminated by 70% ethanol. We conclude that A fumigatus spores can be eradicated from food by heating to a temperature of at least 100 degrees C. When foods cannot be exposed to high temperature or microwaving, ethanol only partially reduces the level of surface contamination.

  8. Effectiveness of automated ultraviolet-C light for decontamination of textiles inoculated with Enterococcus faecium.

    PubMed

    Smolle, C; Huss, F; Lindblad, M; Reischies, F; Tano, E

    2018-01-01

    Healthcare textiles are increasingly recognized as potential vehicles for transmission of hospital-acquired infections. This study tested the ability of an automated ultraviolet-C (UV-C) room disinfection device (Tru-D Smart UV-C) to decontaminate textiles inoculated with Enterococcus faecium in a clinical setting. Contaminated polycotton (50/50 polyester/cotton) swatches were distributed to predefined locations in a ward room and exposed to UV-C light. UV-C decontamination reduced E. faecium counts by a mean log 10 reduction factor of 1.37 (all P = 0.005, Wilcoxon signed rank test). UV-C decontamination may be a feasible adjunctive measure to conventional laundering to preserve the cleanliness of healthcare textiles in ward rooms. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  9. Decontamination Systems Information and Research Program. Quarterly technical progress report, January 1--March 31, 1994

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1994-05-01

    West Virginia University (WVU) and the US DOE Morgantown Energy Technology Center (METC) entered into a Cooperative Agreement on August 29, 1992 entitled ``Decontamination Systems Information and Research Programs.`` Stipulated within the Agreement is the requirement that WVU submit to METC a series of Technical Progress Reports on a quarterly basis. This report comprises the first Quarterly Technical Progress Report for Year 2 of the Agreement. This report reflects the progress and/or efforts performed on the sixteen (16) technical projects encompassed by the Year 2 Agreement for the period of January 1 through March 31, 1994. In situ bioremediation ofmore » chlorinated organic solvents; Microbial enrichment for enhancing in-situ biodegradation of hazardous organic wastes; Treatment of volatile organic compounds (VOCs) using biofilters; Drain-enhanced soil flushing (DESF) for organic contaminants removal; Chemical destruction of chlorinated organic compounds; Remediation of hazardous sites with steam reforming; Soil decontamination with a packed flotation column; Use of granular activated carbon columns for the simultaneous removal of organics, heavy metals, and radionuclides; Monolayer and multilayer self-assembled polyion films for gas-phase chemical sensors; Compact mercuric iodide detector technology development; Evaluation of IR and mass spectrometric techniques for on-site monitoring of volatile organic compounds; A systematic database of the state of hazardous waste clean-up technologies; Dust control methods for insitu nuclear and hazardous waste handling; Winfield Lock and Dam remediation; and Socio-economic assessment of alternative environmental restoration technologies.« less

  10. Decontamination effect of milling by a jet mill on bacteria in rice flour.

    PubMed

    Sotome, Itaru; Nei, Daisuke; Tsuda, Masuko; Mohammed, Sharif Hossen; Takenaka, Makiko; Okadome, Hiroshi; Isobe, Seiichiro

    2011-06-01

    The decontamination effect of milling by a jet mill was investigated by counting the number of bacteria in brown and white rice flour with mean particle diameters of 3, 20, and 40µm prepared by the jet mill. In the jet mill, the particles are crushed and reduced in size by the mechanical impact caused by their collision. Although the brown and white rice grains were contaminated with approximately 10(6) and 10(5) CFU/g bacteria, the microbial load of the rice flour decreased as the mean particle diameter decreased, ultimately decreasing to approximately 104 and 103 CFU/g in the brown and white rice flour. The temperature and pressure changes of the sample were not considered to have an effect on reducing the bacterial count during the milling. Hence, it was thought that the rice flour was decontaminated by other effects.

  11. FY08 Chemical Synthesis for the Self-Decontaminating Coatings Project

    DTIC Science & Technology

    2013-08-01

    These synthesized materials consist of Boltorn hyperbranched polymers that are functionalized with hydantoin, alkyl, and perfluorinated groups. 15...envisioned that completely prevents sorption of chemical agents, enables autonomous decontamination, reduces the volume of cleaning solution...modified with perfluorinated octanoic acid (PFOA), lauric acid, and a hydantoin moiety. HO OH CH3 HO O 3 Figure 2. Synthetic targets 1–3

  12. Reduction of an E. coli O157:H7 and Salmonella composite on fresh strawberries by varying antimicrobial washes and vacuum perfusion.

    PubMed

    Gurtler, Joshua B; Bailey, Rebecca B; Jin, Tony Z; Fan, Xuetong

    2014-10-17

    A 2011 outbreak of hemorrhagic colitis, which resulted in the death of two individuals, was associated with contaminated strawberries. A study was conducted to identify antimicrobial washes effective at reducing E. coli O157:H7 and Salmonella enterica from the surface of fresh whole strawberries during two-minute immersion washes. Twenty-seven antimicrobial treatments were tested. Vacuum perfusion was applied to strawberries during chlorine and peracetic acid treatments to promote infiltration of sanitizer into porous strawberry tissue. Strawberries were inoculated to 7.1logCFU/strawberry with a seven-strain bacterial composite, consisting of three strains of E. coli O157:H7 and four serovars of Salmonella enterica. Berries were air-dried for 2h and immersed in circulating antimicrobial solutions for 120s at 22°C. Four treatments reduced ≥3.0logCFU/strawberry, including (a) 1% acetic acid+1% H2O2, (b) 30% ethanol+1% H2O2, (c) 90ppm peracetic acid, and (d) 1% lactic acid+1% H2O2. Two additional treatments that reduced 2.8logCFU/strawberry were (a) 40% ethanol, and (b) 1% each of phosphoric+fumaric acids. Eight treatments reduced 2.0-2.6logCFU/strawberry. Five treatments reduced <1.45CFU/strawberry, including (a) 1% citric acid, (b) 1% lactic acid, (c) 1% acetic acid, (d) 0.5% each of acetic+citric acids and (e) 0.5% each of acetic+lactic acids. The use of vacuum perfusion with 200ppm chlorine or 90ppm peracetic acid did not reduce greater populations of pathogens than did the same treatments without vacuum perfusion. Fourteen treatments reduced no more pathogens (p<0.05) than did sterile deionized water. Results from this study provide some options for end-point decontamination of strawberries for retail operations just prior to serving to customers. Published by Elsevier B.V.

  13. Evaluation of Combined Disinfection Methods for Reducing Escherichia coli O157:H7 Population on Fresh-Cut Vegetables

    PubMed Central

    Petri, Eva; Rodríguez, Mariola; García, Silvia

    2015-01-01

    Most current disinfection strategies for fresh-cut industry are focused on the use of different chemical agents; however, very little has been reported on the effectiveness of the hurdle technology. The effect of combined decontamination methods based on the use of different sanitizers (peroxyacetic acid and chlorine dioxide) and the application of pressure (vacuum/positive pressure) on the inactivation of the foodborne pathogen E. coli O157:H7 on fresh-cut lettuce (Lactuca sativa) and carrots (Daucus carota) was studied. Fresh produce, inoculated with E. coli O157:H7, was immersed (4 °C, 2 min) in tap water (W), chlorine water (CW), chlorine dioxide (ClO2: 2 mg/L) and peroxyacetic acid (PAA: 100 mg/L) in combination with: (a) vacuum (V: 10 mbar) or (b) positive pressure application (P: 3 bar). The product quality and antimicrobial effects of the treatment on bacterial counts were determined both in process washing water and on fresh-cut produce. Evidence obtained in this study, suggests that the use of combined methods (P/V + sanitizers) results in a reduction on the microorganism population on produce similar to that found at atmospheric pressure. Moreover, the application of physical methods led to a significant detrimental effect on the visual quality of lettuce regardless of the solution used. Concerning the process water, PAA proved to be an effective alternative to chlorine for the avoidance of cross-contamination. PMID:26213954

  14. Evaluation of Combined Disinfection Methods for Reducing Escherichia coli O157:H7 Population on Fresh-Cut Vegetables.

    PubMed

    Petri, Eva; Rodríguez, Mariola; García, Silvia

    2015-07-23

    Most current disinfection strategies for fresh-cut industry are focused on the use of different chemical agents; however, very little has been reported on the effectiveness of the hurdle technology. The effect of combined decontamination methods based on the use of different sanitizers (peroxyacetic acid and chlorine dioxide) and the application of pressure (vacuum/positive pressure) on the inactivation of the foodborne pathogen E. coli O157:H7 on fresh-cut lettuce (Lactuca sativa) and carrots (Daucus carota) was studied. Fresh produce, inoculated with E. coli O157:H7, was immersed (4 °C, 2 min) in tap water (W), chlorine water (CW), chlorine dioxide (ClO2: 2 mg/L) and peroxyacetic acid (PAA: 100 mg/L) in combination with: (a) vacuum (V: 10 mbar) or (b) positive pressure application (P: 3 bar). The product quality and antimicrobial effects of the treatment on bacterial counts were determined both in process washing water and on fresh-cut produce. Evidence obtained in this study, suggests that the use of combined methods (P/V + sanitizers) results in a reduction on the microorganism population on produce similar to that found at atmospheric pressure. Moreover, the application of physical methods led to a significant detrimental effect on the visual quality of lettuce regardless of the solution used. Concerning the process water, PAA proved to be an effective alternative to chlorine for the avoidance of cross-contamination.

  15. Hospital disinfection: efficacy and safety issues.

    PubMed

    Dettenkofer, Markus; Block, Colin

    2005-08-01

    To review recent publications relevant to hospital disinfection (and cleaning) including the reprocessing of medical instruments. The key question as to whether the use of disinfectants on environmental surfaces rather than cleaning with detergents only reduces nosocomial infection rates still awaits conclusive studies. New disinfectants, mainly peroxygen compounds, show good sporicidal properties and will probably replace more problematical substances such as chlorine-releasing agents. The safe reprocessing of medical devices requires a well-coordinated approach, starting with proper cleaning. New methods and substances show promising activity for preventing the transmission of prions. Different aspects of virus inactivation have been studied, and the transmissibility, e.g. of norovirus, shows the need for sound data on how different disinfectant classes perform. Biofilms or other forms of surface-adherent organisms pose an extraordinary challenge to decontamination. Although resistance to biocides is generally not judged to be as critical as antibiotic resistance, scientific data support the need for proper use, i.e. the avoidance of widespread application, especially in low concentrations and in consumer products. Chemical disinfection of heat-sensitive instruments and targeted disinfection of environmental surfaces are established components of hospital infection control. To avoid danger to staff, patients and the environment, prudent use as well as established safety precautions are required. New technologies and products should be evaluated with sound methods. As emerging resistant pathogens will challenge healthcare facilities in the future even more than at present, there is a need for well-designed studies addressing the role of disinfection in hospital infection control.

  16. Application of a phage in decontaminating Vibrio parahaemolyticus in oysters.

    PubMed

    Zhang, Hui; Yang, Zhenquan; Zhou, Yan; Bao, Hongduo; Wang, Ran; Li, Tingwu; Pang, Maoda; Sun, Lichang; Zhou, Xiaohui

    2018-06-20

    Vibrio parahaemolyticus is a major pathogen that is mainly associated with seafood and is a global concern of food safety. With high prevalence of contamination in food, efficient strategy is needed to decontaminate those contaminated foods and control the emergence of vibriosis. In the present study, a V. parahaemolyticus-specific phage vB_VpaS_OMN (designated as phage OMN) was isolated from oyster. Phage OMN had good pH (5-9) and temperature tolerance (<50 °C). Phage OMN exhibited broad host range against isolates of V. parahaemolyticus (20/31). After treatment with phage OMN in the liquid condition for 7 h, the number of V. parahaemolyticus was reduced significantly compared to control treatment. When phage OMN was applied to oyster samples for 48 and 72 h, 90% and 99%, respectively, of V. parahaemolyticus was inactivated on Oyster meat surface. Sequence analysis showed that phage OMN had a 42.202 bp genome and revealed about 59.04% homology with Cronobacter phage vB_CsaP_Ss1. Only 10 CDSs can be predicted based on the GenBank database, while 42% of the CDSs were unique to OMN and had no known function, indicating that phage OMN is a new lytic phage. Fully understanding of the function for the phage genes and the properties of the phage is important for the development of strategies to control V. parahaemolyticus contamination in oysters and disease in aquaculture. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Measures to prevent nosocomial infections during mechanical ventilation.

    PubMed

    Ramirez, Paula; Bassi, Gianluigi L; Torres, Antonio

    2012-02-01

    Endotracheal intubation and mechanical ventilation are lifesaving measures in critically ill patients. However, these interventions increase the risk of respiratory infections, particularly ventilator-associated pneumonia (VAP). VAP constitutes a serious burden for the healthcare system and worsens the patient's outcomes; thus, several preventive strategies have been implemented. This communication reviews the current knowledge on VAP pathogenesis and the latest preventive measures. Pathogen-laden oropharyngeal secretions leak across the endotracheal tube (ETT) cuff; thus, a continuous control of the internal cuff pressure and cuffs made of polyurethane improve sealing effectiveness and associated risks of infections. Subglottic secretions aspiration prevents VAP, and the latest evidence demonstrated a reduction in the incidence of late-onset VAP. The role of ETT biofilm in the pathogenesis of VAP is not fully elucidated. Nevertheless, antimicrobial-coated ETTs have showed beneficial effects in VAP incidence. Recent experimental evidence has challenged the benefits associated with the use of the semirecumbent position; yet, these findings need to be corroborated in clinical trials. The latest results from trials testing the effects of selective digestive decontamination (SDD) showed beneficial effects on patients' outcomes, but concerns remain regarding the emergence of bacterial resistance, specifically upon digestive tract re-colonization. The use of oropharyngeal decontamination with antiseptics and the use of probiotics are potential alternatives to SDD. There is consistent evidence that strategies affecting the primary mechanisms of VAP pathogenesis efficiently reduce the occurrence of the disease. Preventive measures should be implemented grouped into bundles to improve overall efficacy.

  18. Infection control in intensive care units and prevention of ventilator-associated pneumonia.

    PubMed

    Bonten, M J; Weinstein, R A

    2000-12-01

    Ventilator-associated pneumonia (VAP) is considered the most frequent infection in the intensive care unit (ICU), although incidence rates depend on the diagnostic methods. Because VAP has been associated with increased mortality and greater costs for medical care, prevention remains an important goal for intensive care medicine. Selective digestive decontamination (SDD), the most frequently studied method of infection prevention, is still controversial despite more than 30 prospective randomized trials and 6 metaanalyses. SDD reduces the incidence of VAP diagnoses, but beneficial effects on duration of ventilation or ICU stay, antibiotic use, and patient survival have not been shown unequivocally. Although recent metaanalyses suggest a 20% to 40% decrease in ICU mortality for SDD used with systemic prophylaxis, this benefit should be confirmed in a large, prospective, randomized study, preferably with a cost-benefit analysis. Selection of pathogens resistant to the antibiotics used in SDD remains the most important drawback of SDD, rendering SDD contraindicated in wards with endemic resistant problems. Other methods of infection prevention that do not create a selective growth advantage for resistant microorganisms may be more useful. Among these are the use of endotracheal tubes with the possibility of continuous aspiration of subglottic secretions, oropharyngeal decontamination with antiseptics, or the semirecumbent treatment position of patients. Although these methods were successful in single studies, more data are needed. Notwithstanding the potential benefits of these interventions, such classic infection control measures as handwashing remain the cornerstone of infection prevention.

  19. [Selective digestive tract decontamination in intensive care medicine. Fundamentals and current evaluation].

    PubMed

    Krueger, W A; Heininger, A; Unertl, K E

    2003-02-01

    Selective digestive tract decontamination (SDD) is a method where topical non-absorbable antibiotics are applied to the oropharynx and stomach which primarily is aimed at the prevention of ventilator-associated pneumonia. The rationale for SDD is that ventilator associated pneumonia usually originates from the patients'own oropharyngeal microflora. SDD is also used for the prevention of gut-derived infections in acute necrotizing pancreatitis and in liver transplantation. Despite numerous clinical trials and several meta-analyses, SDD is still a controversial topic. It is now commonly accepted that the incidence of pneumonia is reduced,however, the concept of using topical antibiotics has its inherent limitations and the best results have been obtained by combination with a short course of intravenous antibiotics. Several issues surrounding the notorious difficulties in establishing the diagnosis of ventilator-associated pneumonia especially in the presence of antibiotics are an on-going matter of debate.Furthermore, pneumonia is the leading cause of death from nosocomial infections and its prevention was not adequately followed by reduced mortality in most individual trials, however, a benefit was suggested by recalculation of data in meta-analyses. Patients are not well defined by their need for ICU admission and mechanical ventilation and the attributable mortality of infections depends more on the type and severity of the underlying diseases. Recently published trials substantially improved our understanding as to which patients may derive most benefit from SDD.Currently, it seems that an improved survival can be achieved in surgical and trauma patients with severe but salvageable diseases, which might be classified e.g.by calculation of APACHE-II scores on admission.However, the most important drawback of SDD is the development of resistance and an increased selection pressure towards Gram-positive pathogens, especially in institutions with endemic multi-resistant microorganisms.Thus, it appears that "selective" must not only be interpreted as selective suppression of pathogenic bacteria but rather as selection of appropriate groups of patients with respect to underlying diseases and severity of illness. Furthermore, it means selection of ICUs where the endemic resistance patterns might allow the use of SDD at a relatively low risk for selection of resistant microorganisms, which is still the major concern associated with SDD.

  20. Technical Report for the Demonstration of Wide Area ...

    EPA Pesticide Factsheets

    Report The U.S. Environmental Protection Agency in collaboration with the Department of Homeland Security conducted the “Wide-Area Urban Radiological Contaminant, Mitigation, and Cleanup Technology Demonstration” in Columbus, Ohio on June 22-25, 2015. Five wide-area radiological decontamination technologies (including strippable coatings, gels, and chemical foam technologies) were demonstrated on an urban building.

  1. Skin decontamination efficacy of potassium ketoxime on rabbits exposed to sulfur mustard.

    PubMed

    Sun, Jing-Hai; Sun, Pei-Pei; Zheng, Wei; Han, Song; Ying, Ying; Liu, Hong-Yan; Zhang, Cheng; Zhao, Bao-Quan; Zuo, Guo-Min; Lu, Hong; Zhong, Yu-Xu

    2015-03-01

    The chemical weapon sulfur mustard (SM) is a blister agent, and currently, there is no effective antidote. To evaluate the decontamination efficacy of potassium ketoxime against SM and preliminarily elucidate its decontamination mechanism. Potassium ketoxime reacted with SM, and SM residues were tested at different time intervals by T-135 colorimetry after the reaction. Rabbit skin was topically exposed to 2 mg/cm(2) SM, treated with potassium ketoxime 1 min later, and observed after 6, 12, and 24 h. Gas chromatography-mass spectroscopy was employed to screen and identify the main products of potassium ketoxime decontamination of SM. Potassium ketoxime had a great effect against SM contamination. With a mass ratio of decontaminant: SM of 50:1, decontamination rates against SM were 87.5% after 30 s, 95.9% after 1 min, and 99.0% after 5 min. Fifteen minutes after exposure to SM, the untreated group showed clear erythema lesions, whereas the experimental group showed no clear erythema lesions within 6 h. After 12 and 24 h, the areas of damaged skin in the experimental group were 0.038 and 0.125 cm(2), respectively, compared with 2.21 and 2.65 cm(2) in the control group. Histopathological analysis revealed that treatment with potassium ketoxime also reduced inflammation-induced damage. The results of this study indicate that potassium ketoxime reacted rapidly and completely with SM, and thus, it was found to be a suitable and effective skin decontaminant against SM. The decontamination reaction mechanism is mainly related to nucleophilic substitution.

  2. Disinfection of radish and alfalfa seeds inoculated with Escherichia coli O157:H7 and Salmonella by a gaseous acetic acid treatment.

    PubMed

    Nei, Daisuke; Latiful, Bari M; Enomoto, Katsuyoshi; Inatsu, Yasuhiro; Kawamoto, Shinnichi

    2011-10-01

    Abstract The majority of seed sprout-related outbreaks have been associated with Escherichia coli O157:H7 and Salmonella. Therefore, we aimed to find an effective method to inactivate these organisms on seeds before sprouting. Treatment with 8.7% (v/v) acetic acid at 55°C for 2-3 h reduced the population of E. coli O157:H7 and Salmonella inoculated on alfalfa (Medicago sativa L.) and radish seeds (Raphanus sativus L.) by more than 5.0 log CFU/g, and a longer treatment time completely eliminated the E. coli O157:H7 population. The E. coli O157:H7 populations were reduced to an undetectable level with a gaseous acetic acid treatment for 48 h. After enrichment, no E. coli O157:H7 were found in the alfalfa and radish seeds (25 g). However, these treatments were unable to eliminate Salmonella in both seed types. No significant difference between the germination rates of treated alfalfa seeds and control seeds was found, and germination rates greater than 95% were obtained for the radish seeds. Although chlorine washing is commonly used for seed decontamination, chlorine washing at 200 and 20,000 ppm resulted in a reduction of pathogens by less than or equal to 3 log CFU/g. Therefore, these results suggested that gaseous acetic acid is more effective than chlorine washing in controlling pathogenic bacteria on sprout seeds.

  3. Hot, humid air decontamination of a C-130 aircraft contaminated with spores of two acrystalliferous Bacillus thuringiensis strains, surrogates for Bacillus anthracis.

    PubMed

    Buhr, T L; Young, A A; Bensman, M; Minter, Z A; Kennihan, N L; Johnson, C A; Bohmke, M D; Borgers-Klonkowski, E; Osborn, E B; Avila, S D; Theys, A M G; Jackson, P J

    2016-04-01

    To develop test methods and evaluate survival of Bacillus thuringiensis kurstaki cry(-) HD-1 and B. thuringiensis Al Hakam spores after exposure to hot, humid air inside of a C-130 aircraft. Bacillus thuringiensis spores were either pre-inoculated on 1 × 2 or 2 × 2 cm substrates or aerosolized inside the cargo hold of a C-130 and allowed to dry. Dirty, complex surfaces (10 × 10 cm) swabbed after spore dispersal showed a deposition of 8-10 log10 m(-2) through the entire cargo hold. After hot, humid air decontamination at 75-80°C, 70-90% relative humidity for 7 days, 87 of 98 test swabs covering 0·98 m(2) , showed complete spore inactivation. There was a total of 1·67 log10 live CFU detected in 11 of the test swabs. Spore inactivation in the 98 test swabs was measured at 7·06 log10 m(-2) . Laboratory test methods for hot, humid air decontamination were scaled for a large-scale aircraft field test. The C-130 field test demonstrated that hot, humid air can be successfully used to decontaminate an aircraft. Transition of a new technology from research and development to acquisition at a Technology Readiness Level 7 is unprecedented. Published 2016. This article is a U.S. Government work and is in the public domain in the USA.

  4. Advanced DNA-Based Point-of-Care Diagnostic Methods for Plant Diseases Detection.

    PubMed

    Lau, Han Yih; Botella, Jose R

    2017-01-01

    Diagnostic technologies for the detection of plant pathogens with point-of-care capability and high multiplexing ability are an essential tool in the fight to reduce the large agricultural production losses caused by plant diseases. The main desirable characteristics for such diagnostic assays are high specificity, sensitivity, reproducibility, quickness, cost efficiency and high-throughput multiplex detection capability. This article describes and discusses various DNA-based point-of care diagnostic methods for applications in plant disease detection. Polymerase chain reaction (PCR) is the most common DNA amplification technology used for detecting various plant and animal pathogens. However, subsequent to PCR based assays, several types of nucleic acid amplification technologies have been developed to achieve higher sensitivity, rapid detection as well as suitable for field applications such as loop-mediated isothermal amplification, helicase-dependent amplification, rolling circle amplification, recombinase polymerase amplification, and molecular inversion probe. The principle behind these technologies has been thoroughly discussed in several review papers; herein we emphasize the application of these technologies to detect plant pathogens by outlining the advantages and disadvantages of each technology in detail.

  5. Advanced DNA-Based Point-of-Care Diagnostic Methods for Plant Diseases Detection

    PubMed Central

    Lau, Han Yih; Botella, Jose R.

    2017-01-01

    Diagnostic technologies for the detection of plant pathogens with point-of-care capability and high multiplexing ability are an essential tool in the fight to reduce the large agricultural production losses caused by plant diseases. The main desirable characteristics for such diagnostic assays are high specificity, sensitivity, reproducibility, quickness, cost efficiency and high-throughput multiplex detection capability. This article describes and discusses various DNA-based point-of care diagnostic methods for applications in plant disease detection. Polymerase chain reaction (PCR) is the most common DNA amplification technology used for detecting various plant and animal pathogens. However, subsequent to PCR based assays, several types of nucleic acid amplification technologies have been developed to achieve higher sensitivity, rapid detection as well as suitable for field applications such as loop-mediated isothermal amplification, helicase-dependent amplification, rolling circle amplification, recombinase polymerase amplification, and molecular inversion probe. The principle behind these technologies has been thoroughly discussed in several review papers; herein we emphasize the application of these technologies to detect plant pathogens by outlining the advantages and disadvantages of each technology in detail. PMID:29375588

  6. Cold plasma decontamination of foods.

    PubMed

    Niemira, Brendan A

    2012-01-01

    Cold plasma is a novel nonthermal food processing technology that uses energetic, reactive gases to inactivate contaminating microbes on meats, poultry, fruits, and vegetables. This flexible sanitizing method uses electricity and a carrier gas, such as air, oxygen, nitrogen, or helium; antimicrobial chemical agents are not required. The primary modes of action are due to UV light and reactive chemical products of the cold plasma ionization process. A wide array of cold plasma systems that operate at atmospheric pressures or in low pressure treatment chambers are under development. Reductions of greater than 5 logs can be obtained for pathogens such as Salmonella, Escherichia coli O157:H7, Listeria monocytogenes, and Staphylococcus aureus. Effective treatment times can range from 120 s to as little as 3 s, depending on the food treated and the processing conditions. Key limitations for cold plasma are the relatively early state of technology development, the variety and complexity of the necessary equipment, and the largely unexplored impacts of cold plasma treatment on the sensory and nutritional qualities of treated foods. Also, the antimicrobial modes of action for various cold plasma systems vary depending on the type of cold plasma generated. Optimization and scale up to commercial treatment levels require a more complete understanding of these chemical processes. Nevertheless, this area of technology shows promise and is the subject of active research to enhance efficacy.

  7. Decontamination and decorporation: the clinical experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poda, G.A.

    1979-01-01

    Decontamination and decorporation are quite interrelated when dealing with a contaminated person. Some clinical experiences from a transuranium production facility are offered. Skin decontamination is accomplished by washing with detergent and water. Stubborn cases are treated with sodium hypochlorite followed by rinsing, and emery cloth is used on more stubborn nail or finger pad contamination. If inhaled, the usual skin cleansing followed by nasal douche with normal saline decontaminates reachable areas and one of the DTPA salts given via aerosol both decontaminates and decorporates the inner recesses. Saline laxative reduces the time inhaled, and ingested particles remain in the gastro-intestinalmore » tract. Conservatism prevails in general, but most persons found to have inhaled contamination are given a single chelation within the hour of discovery and if subsequently found to have over 10% M.P.P.B. of a soluble actinide are offered further chelation. Single dose chelation has been found to be relatively innocuous and usually sufficient. The longest case of chelation therapy spanned 2-1/4 years and encompassed 123 doses of CaNa-DTPA.« less

  8. Efficacy of various antimicrobials on reduction of salmonella and campylobacter and quality attributes of ground chicken obtained from poultry parts treated in a postchill decontamination tank.

    PubMed

    Chen, Xi; Bauermeister, Laura J; Hill, Gretchen N; Singh, Manpreet; Bilgili, Sacit F; McKee, Shelly R

    2014-11-01

    Ground chicken is likely to have higher microbiological loads than whole carcasses and parts. Therefore, it is necessary to identify antimicrobials that reduce pathogens and overall microbial loads without negatively impacting meat quality. The objectives of this research were to evaluate the effect of various postchill antimicrobials on reducing Salmonella and Campylobacter, and determine the impact of these treatments on shelf life and quality attributes of ground chicken. Five treatments (0.003% chlorine, 0.07 and 0.1% peracetic acid [PAA], and 0.35 and 0.6% cetylpyridinium chloride [CPC]) were evaluated. Samples (n = 120) of skin-on chicken breast and thigh meat were inoculated with Salmonella Typhimurium (10(8) CFU/ml) and C. jejuni (10(8) CFU/ml). Following a 30-min attachment time, parts were rinsed with either chlorine, PAA, or CPC in a decontamination tank for 23 s. Parts then were ground, samples (25 g) were plated, and reduction of Salmonella Typhimurium and C. jejuni was determined. Noninoculated ground breast and thigh meat were used for sensory and shelf-life determination. Samples (n = 200) for shelf-life determination were collected on days 1, 4, 7, and 10 to estimate spoilage microflora of ground chicken stored at 4°C. Additionally, color measurement and sensory evaluation were conducted on days 1, 4, and 7. Ground chicken treated with 0.07 and 0.1% PAA had the greatest reductions (P ≤ 0.05) in Salmonella and Campylobacter providing approximately a 1.5-log reduction, followed by a 0.8-log reduction after treatment with 0.35 and 0.6% CPC. Chlorine (0.003%) was the least effective treatment (P ≤ 0.05), while treatments with 0.07 and 0.1% PAA also extended the shelf life of ground chicken for 3 days. None of the treatments had negative impact on color or sensory attributes of ground chicken patties during the storage (P ≤ 0.05). Results from this study indicated that using PAA as an antimicrobial agent in a postchill decontamination tank to treat ground poultry parts is effective for the reduction of Salmonella and Campylobacter while maintaining product quality.

  9. 2007 Joint Chemical Biological, Radiological and Nuclear (CBRN) Conference and Exhibition - Combating Weapons of Mass Destruction

    DTIC Science & Technology

    2007-06-27

    Selected CB Defense Systems SHAPESENSE Joint Warning and Reporting Network JSLIST CB Protected Shelter Joint Vaccine Acquisition Program Joint Effects...military can operate in any environment, unconstrained by chemical or biological weapons. 21 SHIELD SUSTAIN Selected CB Defense Systems SHAPESENSE Joint...28070625_JCBRN_Conference_Reeves UNCLASSIFIED Decontamination Vision Strippable Barriers Self-Decontaminating Fabrics/Coatings Reduce Logistics Burden

  10. Bioinspired Surface Treatments for Improved Decontamination: Handling andDecontamination Considerations

    DTIC Science & Technology

    2018-03-16

    this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data...sources, gathering and maintaining the data needed, and completing and reviewing this collection of information . Send comments regarding this burden...estimate or any other aspect of this collection of information , including suggestions for reducing this burden to Department of Defense, Washington

  11. Extra-corporeal membrane oxygenation-associated infections: implication of extra-intestinal pathogenic Escherichia coli clones.

    PubMed

    Messika, Jonathan; Clermont, Olivier; Landraud, Luce; Schmidt, Matthieu; Aubry, Alexandra; Sougakoff, Wladimir; Fernandes, Romain; Combes, Alain; Denamur, Erick; Ricard, Jean-Damien

    2017-08-01

    Extra-corporeal membrane oxygenation (ECMO) is a promising life-saving technique for critically ill patients. Bacterial infection is a frequent complication, and Escherichia coli the predominant causative pathogen, but little is known about the characteristics of E. coli strains in these infections. We therefore conducted a retrospective study of 33 E. coli strains responsible for 33 ECMO-related infections, in 30 subjects. Antimicrobial susceptibility, phylotyping, O-typing, clonal relatedness determination and the screening for four virulence factor genes were conducted. Polymicrobial infections were evidenced in 61.6 % of episodes, irrespective of E. coli characteristics. Extra-intestinal pathogenic strains represented the large majority (69.7 %) of all E. coli isolates. Their advantageous genetic background may explain their predominance in this context. The potential for targeted digestive decontamination should be investigated in these patients for whom infectious complications are a heavy burden.

  12. Comparative study on decontamination treatment of paper-based materials in corona discharge and HF cold plasma

    NASA Astrophysics Data System (ADS)

    Ioanid, E. G.; Dunca, S.; Rusu, D.; Tǎnase, C.

    2012-04-01

    Documents decontamination using dry methods, less invasive than the wet ones implying toxic nocuous substances for cellulose-based materials, has been the object of numerous studies. In recent years mixed researchers teams have been studying the possibility of one-step document decontamination performed by a dry treatment, the risks of repeated wet manipulation thus being reduced. Among physical methods appropriate to this end, high-frequency cold plasma and corona effect can be mentioned. Our studies were carried out on samples taken from ancient books with no cultural heritage value. The decontamination efficiency and the impact on paper of the two types of treatments were determined by: microbiological analysis, scanning electron microscopy, FTIR, chromatic alterations and gloss determination. The above-mentioned procedures eliminate the use of chemical conservation substances, nocuous for the paper support. At the same time the health risk for conservators, restorers, archivists or archive's users is removed.

  13. Chemical warfare agent simulants for human volunteer trials of emergency decontamination: A systematic review

    PubMed Central

    Wyke, Stacey; Marczylo, Tim; Collins, Samuel; Gaulton, Tom; Foxall, Kerry; Amlôt, Richard; Duarte‐Davidson, Raquel

    2017-01-01

    Abstract Incidents involving the release of chemical agents can pose significant risks to public health. In such an event, emergency decontamination of affected casualties may need to be undertaken to reduce injury and possible loss of life. To ensure these methods are effective, human volunteer trials (HVTs) of decontamination protocols, using simulant contaminants, have been conducted. Simulants must be used to mimic the physicochemical properties of more harmful chemicals, while remaining non‐toxic at the dose applied. This review focuses on studies that employed chemical warfare agent simulants in decontamination contexts, to identify those simulants most suitable for use in HVTs of emergency decontamination. Twenty‐two simulants were identified, of which 17 were determined unsuitable for use in HVTs. The remaining simulants (n = 5) were further scrutinized for potential suitability according to toxicity, physicochemical properties and similarities to their equivalent toxic counterparts. Three suitable simulants, for use in HVTs were identified; methyl salicylate (simulant for sulphur mustard), diethyl malonate (simulant for soman) and malathion (simulant for VX or toxic industrial chemicals). All have been safely used in previous HVTs, and have a range of physicochemical properties that would allow useful inference to more toxic chemicals when employed in future studies of emergency decontamination systems. PMID:28990191

  14. Towards pathogen inactivation of red blood cells and whole blood targeting viral DNA/RNA: design, technologies, and future prospects for developing countries.

    PubMed

    Drew, Victor J; Barro, Lassina; Seghatchian, Jerard; Burnouf, Thierry

    2017-10-01

    Over 110 million units of blood are collected yearly. The need for blood products is greater in developing countries, but so is the risk of contracting a transfusion-transmitted infection. Without efficient donor screening/viral testing and validated pathogen inactivation technology, the risk of transfusion-transmitted infections correlates with the infection rate of the donor population. The World Health Organization has published guidelines on good manufacturing practices in an effort to ensure a strong global standard of transfusion and blood product safety. Sub-Saharan Africa is a high-risk region for malaria, human immunodeficiency virus (HIV), hepatitis B virus and syphilis. Southeast Asia experiences high rates of hepatitis C virus. Areas with a tropical climate have an increased risk of Zika virus, Dengue virus, West Nile virus and Chikungunya, and impoverished countries face economical limitations which hinder efforts to acquire the most modern pathogen inactivation technology. These systems include Mirasol ® Pathogen Reduction Technology, INTERCEPT ® , and THERAFLEX ® . Their procedures use a chemical and ultraviolet or visible light for pathogen inactivation and significantly decrease the threat of pathogen transmission in plasma and platelets. They are licensed for use in Europe and are used in several other countries. The current interest in the blood industry is the development of pathogen inactivation technologies that can treat whole blood (WB) and red blood cell (RBC). The Mirasol system has recently undergone phase III clinical trials for treating WB in Ghana and has demonstrated some efficacy toward malaria inactivation and low risk of adverse effects. A 2 nd -generation of the INTERCEPT ® S-303 system for WB is currently undergoing a phase III clinical trial. Both methodologies are applicable for WB and components derived from virally reduced WB or RBC.

  15. Towards pathogen inactivation of red blood cells and whole blood targeting viral DNA/RNA: design, technologies, and future prospects for developing countries

    PubMed Central

    Drew, Victor J.; Barro, Lassina; Seghatchian, Jerard; Burnouf, Thierry

    2017-01-01

    Over 110 million units of blood are collected yearly. The need for blood products is greater in developing countries, but so is the risk of contracting a transfusion-transmitted infection. Without efficient donor screening/viral testing and validated pathogen inactivation technology, the risk of transfusion-transmitted infections correlates with the infection rate of the donor population. The World Health Organization has published guidelines on good manufacturing practices in an effort to ensure a strong global standard of transfusion and blood product safety. Sub-Saharan Africa is a high-risk region for malaria, human immunodeficiency virus (HIV), hepatitis B virus and syphilis. Southeast Asia experiences high rates of hepatitis C virus. Areas with a tropical climate have an increased risk of Zika virus, Dengue virus, West Nile virus and Chikungunya, and impoverished countries face economical limitations which hinder efforts to acquire the most modern pathogen inactivation technology. These systems include Mirasol® Pathogen Reduction Technology, INTERCEPT®, and THERAFLEX®. Their procedures use a chemical and ultraviolet or visible light for pathogen inactivation and significantly decrease the threat of pathogen transmission in plasma and platelets. They are licensed for use in Europe and are used in several other countries. The current interest in the blood industry is the development of pathogen inactivation technologies that can treat whole blood (WB) and red blood cell (RBC). The Mirasol system has recently undergone phase III clinical trials for treating WB in Ghana and has demonstrated some efficacy toward malaria inactivation and low risk of adverse effects. A 2nd-generation of the INTERCEPT® S-303 system for WB is currently undergoing a phase III clinical trial. Both methodologies are applicable for WB and components derived from virally reduced WB or RBC. PMID:28488960

  16. Application of slightly acidic electrolyzed water for decontamination of stainless steel surfaces in animal transport vehicles.

    PubMed

    Ni, Li; Zheng, Weichao; Zhang, Qiang; Cao, Wei; Li, Baoming

    2016-10-01

    The effectiveness of slightly acidic electrolyzed water (SAEW) in reducing Escherichia coli, Salmonella typhimurim, Staphylococcus aureus or bacterial mixtures on stainless steel surfaces was evaluated and compared its efficacy with composite phenol solution for reducing total aerobic bacteria in animal transport vehicles. Stainless steel surfaces were inoculated with these strains individually or in a mixture, and sprayed with SAEW, composite phenol, or alkaline electrolyzed water for 0.5, 1, 1.5 and 2min. The bactericidal activity of SAEW increased with increasing available chlorine concentration and spraying duration. The SAEW solution of 50mgl -1 of available chlorine concentration showed significantly higher effectiveness than composite phenol in reducing the pathogens on stainless steel surfaces (P<0.05). Complete inactivation of pathogens on stainless steel surfaces were observed after treatment with alkaline electrolyzed water followed by SAEW at 50mgl -1 of available chlorine concentration for 2min or alkaline electrolyzed water treatment followed by SAEW treatment at 90mgl -1 of available chlorine concentration for 0.5min. The efficacy of SAEW in reducing total aerobic bacteria in animal transport vehicles was also determined. Vehicles in the disinfection booth were sprayed with the same SAEW, alkaline electrolyzed water and composite phenol solutions using the automatic disinfection system. Samples from vehicle surfaces were collected with sterile cotton swabs before and after each treatment. No significant differences in bactericidal efficiency were observed between SAEW and composite phenol for reducing total aerobic bacteria in the vehicles (P>0.05). SAEW was also found to be more effective when used in conjunction with alkaline electrolyzed water. Results suggest that the bactericidal efficiency of SAEW was higher than or equivalent to that of composite phenol and SAEW may be used as effective alternative for reducing microbial contamination of animal transport vehicles. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Bacterial contamination of re-usable laryngoscope blades during the course of daily anaesthetic practice.

    PubMed

    Lowman, Warren; Venter, Laurissa; Scribante, Juan

    2013-02-19

    Hospital-acquired infections (HAIs) are largely preventable through risk analysis and modification of practice. Anaesthetic practice plays a limited role in the prevention of HAIs, although laryngoscope use and decontamination is an area of concern. We aimed to assess the level of microbial contamination of re-usable laryngoscope blades at a public hospital in South Africa. The theatre complex of a secondary-level public hospital in Johannesburg. Blades from two different theatres were sampled twice daily, using a standardised technique, over a 2-week period. Samples were quantitatively assessed for microbial contamination, and stratified by area on blade, theatre and time using Fisher's exact test. A contamination rate of 57.3% (63/110) was found, with high-level contamination accounting for 22.2% of these. Common commensals were the most frequently isolated micro-organisms (79.1%), but important hospital pathogens such as Enterobacter species and Acinetobacter baumannii were isolated from blades with high-level contamination. No significant difference in the level of microbial contamination by area on blade, theatre or time was found (p<0.05). A combination of sub-optimal decontamination and improper handling of laryngoscopes after decontamination results in significant microbial contamination of re-usable laryngoscope blades. There is an urgent need to review protocols and policies surrounding the use of these blades.

  18. Novel Prevention Strategies for Bacterial Infections in Cirrhosis

    PubMed Central

    Yan, Kathleen; Garcia-Tsao, Guadalupe

    2016-01-01

    Introduction Bacterial infections are a serious complication of cirrhosis, as they can lead to decompensation, multiple organ failure, and/or death. Preventing infections is therefore very relevant. Because gut bacterial translocation is their main pathogenic mechanism, prevention of infections is mostly based on the use of orally administered poorly absorbed antibiotics such as norfloxacin (selective intestinal decontamination). However, antibiotic prophylaxis leads to antibiotic resistance, limiting therapy and increasing morbidity and mortality. Prevention of bacterial infections in cirrhosis should therefore move away from antibiotics. Areas Covered This review focuses on various potentially novel methods to prevent infections in cirrhosis focusing on non-antibiotic strategies. The use of probiotics, nonselective intestinal decontamination with rifaximin, prokinetics and beta-blockers or fecal microbiota transplant as means of targeting altered gut microbiota, bile acids and FXR agonists are all potential alternatives to selective intestinal decontamination. Prokinetics and beta-blockers can improve intestinal motility, while bile acids and FXR agonists help by improving the intestinal barrier. Finally, granulocyte colony stimulating factor (G-CSF) and statins are emerging therapeutic strategies that may improve immune dysfunction in cirrhosis. Expert Opinion Evidence for these strategies has been restricted to animal studies and proof-of concept studies but we expect this to change in coming years. PMID:26799197

  19. Residual antibiotics in decontaminated human cardiovascular tissues intended for transplantation and risk of falsely negative microbiological analyses.

    PubMed

    Buzzi, Marina; Guarino, Anna; Gatto, Claudio; Manara, Sabrina; Dainese, Luca; Polvani, Gianluca; Tóthová, Jana D'Amato

    2014-01-01

    We investigated the presence of antibiotics in cryopreserved cardiovascular tissues and cryopreservation media, after tissue decontamination with antibiotic cocktails, and the impact of antibiotic residues on standard tissue bank microbiological analyses. Sixteen cardiovascular tissues were decontaminated with bank-prepared cocktails and cryopreserved by two different tissue banks according to their standard operating procedures. Before and after decontamination, samples underwent microbiological analysis by standard tissue bank methods. Cryopreserved samples were tested again with and without the removal of antibiotic residues using a RESEP tube, after thawing. Presence of antibiotics in tissue homogenates and processing liquids was determined by a modified agar diffusion test. All cryopreserved tissue homogenates and cryopreservation media induced important inhibition zones on both Staphylococcus aureus- and Pseudomonas aeruginosa-seeded plates, immediately after thawing and at the end of the sterility test. The RESEP tube treatment markedly reduced or totally eliminated the antimicrobial activity of tested tissues and media. Based on standard tissue bank analysis, 50% of tissues were found positive for bacteria and/or fungi, before decontamination and 2 out of 16 tested samples (13%) still contained microorganisms after decontamination. After thawing, none of the 16 cryopreserved samples resulted positive with direct inoculum method. When the same samples were tested after removal of antibiotic residues, 8 out of 16 (50%) were contaminated. Antibiotic residues present in tissue allografts and processing liquids after decontamination may mask microbial contamination during microbiological analysis performed with standard tissue bank methods, thus resulting in false negatives.

  20. Residual Antibiotics in Decontaminated Human Cardiovascular Tissues Intended for Transplantation and Risk of Falsely Negative Microbiological Analyses

    PubMed Central

    Gatto, Claudio; Manara, Sabrina; Dainese, Luca; Polvani, Gianluca; Tóthová, Jana D'Amato

    2014-01-01

    We investigated the presence of antibiotics in cryopreserved cardiovascular tissues and cryopreservation media, after tissue decontamination with antibiotic cocktails, and the impact of antibiotic residues on standard tissue bank microbiological analyses. Sixteen cardiovascular tissues were decontaminated with bank-prepared cocktails and cryopreserved by two different tissue banks according to their standard operating procedures. Before and after decontamination, samples underwent microbiological analysis by standard tissue bank methods. Cryopreserved samples were tested again with and without the removal of antibiotic residues using a RESEP tube, after thawing. Presence of antibiotics in tissue homogenates and processing liquids was determined by a modified agar diffusion test. All cryopreserved tissue homogenates and cryopreservation media induced important inhibition zones on both Staphylococcus aureus- and Pseudomonas aeruginosa-seeded plates, immediately after thawing and at the end of the sterility test. The RESEP tube treatment markedly reduced or totally eliminated the antimicrobial activity of tested tissues and media. Based on standard tissue bank analysis, 50% of tissues were found positive for bacteria and/or fungi, before decontamination and 2 out of 16 tested samples (13%) still contained microorganisms after decontamination. After thawing, none of the 16 cryopreserved samples resulted positive with direct inoculum method. When the same samples were tested after removal of antibiotic residues, 8 out of 16 (50%) were contaminated. Antibiotic residues present in tissue allografts and processing liquids after decontamination may mask microbial contamination during microbiological analysis performed with standard tissue bank methods, thus resulting in false negatives. PMID:25397402

  1. Modeling of capacitively and inductively coupled plasma for molecular decontamination

    NASA Astrophysics Data System (ADS)

    Mihailova, Diana; Hagelaar, Gerjan; Belenguer, Philippe; Laurent, Christopher; Lo, Juslan; Caillier, Bruno; Therese, Laurent; Guillot, Philippe

    2013-09-01

    This project aims to study and to develop new technology bricks for next generation of molecular decontamination systems, including plasma solution, for various applications. The contamination control in the processing stages is a major issue for the industrial performance as well as for the development of new technologies in the surface treatment area. The main task is to create uniform low temperature plasma inside a reactor containing the object to be treated. Different plasma sources are modeled with the aim of finding the most efficient one for surface decontamination: inductively coupled plasma, capacitively coupled plasma and combination of both. The model used for testing the various plasma sources is a time dependent two-dimensional multi-fluid model. The model is applied to a simplified cylindrically symmetric geometry in pure argon gas. The modeling results are validated by comparison with experimental results and observations based on optical and physical diagnostic tools. The influence of various parameters (power, pressure, flow) is studied and the corresponding results are presented, compared and discussed. This work has been performed in the frame of the collaborative program PAUD (Plasma Airborne molecular contamination Ultra Desorption) funded by the French agency OSEO and certified by French global competitive clusters Minalogic and Trimatec.

  2. Implementation of innovative pulsed xenon ultraviolet (PX-UV) environmental cleaning in an acute care hospital.

    PubMed

    Fornwalt, Lori; Riddell, Brad

    2014-01-01

    It is widely acknowledged that the hospital environment is an important reservoir for many of the pathogenic microbes associated with health care-associated infections (HAIs). Environmental cleaning plays an important role in the prevention and containment of HAIs, in patient safety, and the overall experience of health care facilities. New technologies, such as pulsed xenon ultraviolet (PX-UV) light systems are an innovative development for enhanced cleaning and decontamination of hospital environments. A portable PX-UV disinfection device delivers pulsed UV light to destroy microbial pathogens and spores, and can be used in conjunction with manual environmental cleaning. In addition, this technology facilitates thorough disinfection of hospital rooms in 10-15 minutes. The current study was conducted to evaluate whether the introduction of the PX-UV device had a positive impact on patient satisfaction. Satisfaction was measured using the Hospital Consumer Assessment of Healthcare Providers and Systems (HCAHPS) survey. In 2011, prior to the introduction of the PX-UV system, patient HCAHPS scores for cleanliness averaged 75.75%. In the first full quarter after enhanced cleaning of the facility was introduced, this improved to 83%. Overall scores for the hospital rose from 76% (first quarter, 2011) to 87.6% (fourth quarter, 2012). As a result of this improvement, the hospital received 1% of at-risk reimbursement from the inpatient prospective payment system as well as additional funding. Cleanliness of the hospital environment is one of the questions included in the HCAHPS survey and one measure of patient satisfaction. After the introduction of the PX-UV system, the score for cleanliness and the overall rating of the hospital rose from below the fiftieth to the ninety-ninth percentile. This improvement in the patient experience was associated with financial benefits to the hospital.

  3. Decontamination of spent ion-exchangers contaminated with cesium radionuclides using resorcinol-formaldehyde resins.

    PubMed

    Palamarchuk, Marina; Egorin, Andrey; Tokar, Eduard; Tutov, Mikhail; Marinin, Dmitry; Avramenko, Valentin

    2017-01-05

    The origin of the emergence of radioactive contamination not removable in the process of acid-base regeneration of ion-exchange resins used in treatment of technological media and liquid radioactive waste streams has been determined. It has been shown that a majority of cesium radionuclides not removable by regeneration are bound to inorganic deposits on the surface and inside the ion-exchange resin beads. The nature of the above inorganic inclusions has been investigated by means of the methods of electron microscopy, IR spectrometry and X-ray diffraction. The method of decontamination of spent ion-exchange resins and zeolites contaminated with cesium radionuclides employing selective resorcinol-formaldehyde resins has been suggested. Good prospects of such an approach in deep decontamination of spent ion exchangers have been demonstrated. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Institutionalizing Emerging Technology Assessment Process into National Incident Response

    DTIC Science & Technology

    2013-10-01

    mechanical methods, devices, and products, including oil sensors, booms, skimmers, decontamination , and waste minimization technologies...handling). • Alternative Oil Spill Response Technologies (in situ burning , dispersants, etc.). • Oil Spill Damage Assessment and Restoration. The TETs...deaths of eleven crewmembers and a subsequent uncontrolled oil spill that tested the government’s ability to respond to a spill of this magnitude as

  5. Analysis of waste management issues arising from a field study evaluating decontamination of a biological agent from a building.

    PubMed

    Lemieux, P; Wood, J; Drake, J; Minamyer, S; Silvestri, E; Yund, C; Nichols, T; Ierardi, M; Amidan, B

    2016-01-01

    The Bio-response Operational Testing and Evaluation (BOTE) Project was a cross-government effort designed to operationally test and evaluate a response to a biological incident (release of Bacillus anthracis [Ba] spores, the causative agent for anthrax) from initial public health and law enforcement response through environmental remediation. The BOTE Project was designed to address site remediation after the release of a Ba simulant, Bacillus atrophaeus spp. globigii (Bg), within a facility, drawing upon recent advances in the biological sampling and decontamination areas. A key component of response to a biological contamination incident is the proper management of wastes and residues, which is woven throughout all response activities. Waste is generated throughout the response and includes items like sampling media packaging materials, discarded personal protective equipment, items removed from the facility either prior to or following decontamination, aqueous waste streams, and materials generated through the application of decontamination technologies. The amount of residual contaminating agent will impact the available disposal pathways and waste management costs. Waste management is an integral part of the decontamination process and should be included through "Pre-Incident" response planning. Overall, the pH-adjusted bleach decontamination process generated the most waste from the decontamination efforts, and fumigation with chlorine dioxide generated the least waste. A majority of the solid waste generated during pH-adjusted bleach decontamination was the nonporous surfaces that were removed, bagged, decontaminated ex situ, and treated as waste. The waste during the two fumigation rounds of the BOTE Project was associated mainly with sampling activities. Waste management activities may represent a significant contribution to the overall cost of the response/recovery operation. This paper addresses the waste management activities for the BOTE field test. Management of waste is a critical element of activities dealing with remediation of buildings and outdoor areas following a biological contamination incident. Waste management must be integrated into the overall remediation process, along with sampling, decontamination, resource management, and other important response elements, rather than being a stand-alone activity. The results presented in this paper will provide decision makers and emergency planners at the federal/state/tribal/local level information that can be used to integrate waste management into an overall systems approach to planning and response activities.

  6. Environmental assessment of the potential effects of aquifer thermal energy storage systems on microorganisms in groundwater

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hicks, R.J.; Stewart, D.L.

    1988-03-01

    The primary objective of this study was to evaluate the potential environmental effects (both adverse and beneficials) of aquifer thermal energy storage (ATES) technology pertaining to microbial communities indigenous to subsurface environments (i.e., aquifers) and the propagation, movement, and potential release of pathogenic microorganisms (specifically, Legionella) within ATES systems. Seasonal storage of thermal energy in aquifers shows great promise to reduce peak demand; reduce electric utility load problems; contribute to establishing favorable economics for district heating and cooling systems; and reduce pollution from extraction, refining, and combustion of fossil fuels. However, concerns that the widespread implementation of this technology maymore » have adverse effects on biological systems indigeneous to aquifers, as well as help to propagate and release pathogenic organisms that enter thee environments need to be resolved. 101 refs., 2 tabs.« less

  7. Microbiology for Radiologists: How to Minimize Infection Transmission in the Radiology Department.

    PubMed

    Mirza, Sobia K; Tragon, Tyson R; Fukui, Melanie B; Hartman, Matthew S; Hartman, Amy L

    2015-01-01

    The implementation of standardized infection control and prevention practices is increasingly relevant as modern radiology practice evolves into its more clinical role. Current Centers for Disease Control and Prevention, National Institutes of Health, and World Health Organization guidelines for the proper use of personal protective equipment, decontamination of reusable medical equipment, and appropriate management of bloodborne pathogen exposures will be reviewed. Standard precautions apply to all patients at all times and are the mainstay of infection control. Proper hand hygiene includes washing hands with soap and water when exposed to certain infectious particles, such as Clostridium difficile spores, which are not inactivated by alcohol-based hand rubs. The appropriate use of personal protective equipment in accordance with recommendations from the Centers for Disease Control and Prevention includes wearing a surgical mask during lumbar puncture. Because radiologists may perform lumbar punctures for patients with prion disease, it is important to appreciate that incineration is the most effective method of inactivating prion proteins. However, there is currently no consensus recommendation on the decontamination of prion-contaminated reusable items associated with lumbar puncture, and institutional policies should be consulted for directed management. In the event of a needlestick injury, radiology staff must be able to quickly provide appropriate initial management and seek medical attention, including laboratory testing for bloodborne pathogens. ©RSNA, 2015.

  8. Bacterial contamination of fabric and metal-bead identity card lanyards: a cross-sectional study.

    PubMed

    Pepper, Thomas; Hicks, Georgina; Glass, Stephen; Philpott-Howard, John

    2014-01-01

    In healthcare, fabric or metal-bead lanyards are universally used for carrying identity cards. However there is little information on microbial contamination with potential pathogens that may readily re-contaminate disinfected hands. We examined 108 lanyards from hospital staff. Most grew skin flora but 7/108 (6%) had potentially pathogenic bacteria: four grew methicillin-susceptible Staphylococcus aureus, and four grew probable fecal flora: 3 Clostridium perfringens and 1 Clostridium bifermentans (one lanyard grew both S. aureus and C. bifermentans). Unused (control) lanyards had little or no such contamination. The median duration of lanyard wear was 12 months (interquartile range 3-36 months). 17/108 (16%) of the lanyards had reportedly undergone decontamination including wiping with alcohol, chlorhexidine or chlorine dioxide; and washing with soap and water or by washing machine. Metal-bead lanyards had significantly lower median bacterial counts than those from fabric lanyards (1 vs. 4 CFU/cm(2); Mann-Whitney U=300.5; P<0.001). 12/32 (38%) of the metal-bead lanyards grew no bacteria, compared with 2/76 (3%) of fabric lanyards. We recommend that an effective decontamination regimen be instituted by those who use fabric lanyards, or that fabric lanyards be discarded altogether in preference for metal-bead lanyards or clip-on identity cards. Copyright © 2014 King Saud Bin Abdulaziz University for Health Sciences. Published by Elsevier Ltd. All rights reserved.

  9. ELECTROKINETIC REMEDIATION: BASICS AND TECHNOLOGY STATUS

    EPA Science Inventory

    Electrokinetic remediation, variably named as electrochemical soil processing, electromigration, electrokinetic decontamination or electroreclamation uses electric currents to extract radionuclides, heavy metals, certain organic compounds, or mixed inorganic species and some orga...

  10. Decontamination in a Russian settlement.

    PubMed

    Fogh, C L; Andersson, K G; Barkovsky, A N; Mishine, A S; Ponamarjov, A V; Ramzaev, V P; Roed, J

    1999-04-01

    Decontamination was carried out in an area with three houses in Novo Bobovichi, Bryansk region, Russia, in the autumn of 1995. It was demonstrated that significant reductions in the dose rate both indoor (DRF = 0.34) and outdoor (DRF = 0.20) can be achieved when a controlled cleaning is undertaken. This paper describes the decontamination work carried out and the results obtained. The roofs of the houses were swept and cleaned by special roof cleaning equipment. The soil around the houses was removed by hand while carefully monitoring the ground for residual contamination. By monitoring the decline in the dose rate during the different stages of the work the dose reducing effect of each action has been measured.

  11. A novel copper-hydrogen peroxide formulation for prion decontamination.

    PubMed

    Solassol, Jerome; Pastore, Manuela; Crozet, Carole; Perrier, Veronique; Lehmann, Sylvain

    2006-09-15

    With the appearance of variant Creutzfeldt-Jakob disease (CJD) and the detection of infectious prions in the peripheral organs of persons with sporadic CJD, the development of decontamination methods that are compatible with medical equipment has become a major issue. Here, we show that a formulation of copper metal ions in combination with hydrogen peroxide dramatically reduces the level of prion protein (PrP)(Sc) (the scrapie isoform of PrP) present in homogenates of samples from prion-infected brains, including brain samples from humans with CJD. An animal bioassay confirmed the reduction in prion infectivity, indicating that this novel Cu(2+)-H(2)O(2) formulation has great potential for prion decontamination.

  12. Application of a Virucidal Agent to Avoid Overestimation of Phage Kill During Phage Decontamination Assays on Ready-to-Eat Meats.

    PubMed

    Chibeu, Andrew; Balamurugan, S

    2018-01-01

    We describe a method for assessing the effectiveness of tea extract based virucide (TeaF) application to remove phage LISTEX™ P100 not bound to Listeria monocytogenes from stomached rinses prior to direct plating and bacterial enumeration, where the phage is being used as a decontaminant to reduce L. monocytogenes levels on ready-to-eat meat.

  13. Individual external doses below the lowest reference level of 1 mSv per year five years after the 2011 Fukushima nuclear accident among all children in Soma City, Fukushima: A retrospective observational study.

    PubMed

    Tsubokura, Masaharu; Murakami, Michio; Nomura, Shuhei; Morita, Tomohiro; Nishikawa, Yoshitaka; Leppold, Claire; Kato, Shigeaki; Kami, Masahiro

    2017-01-01

    After the 2011 Fukushima Daiichi nuclear power plant accident, little information has been available on individual doses from external exposure among residents living in radioactively contaminated areas near the nuclear plant; in the present study we evaluated yearly changes in the doses from external exposure after the accident and the effects of decontamination on external exposure. This study considered all children less than 16 years of age in Soma City, Fukushima who participated in annual voluntary external exposure screening programs during the five years after the accident (n = 5,363). In total, 14,405 screening results were collected. The median participant age was eight years. The geometric mean levels of annual additional doses from external exposure attributable to the Fukushima accident, decreased each year: 0.60 mSv (range: not detectable (ND)-4.29 mSv), 0.37 mSv (range: ND-3.61 mSv), 0.22 mSv (range: ND-1.44 mSv), 0.20 mSv (range: ND-1.87 mSv), and 0.17 mSv (range: ND-0.85 mSv) in 2011, 2012, 2013, 2014, and 2015, respectively. The proportion of residents with annual additional doses from external exposure of more than 1 mSv dropped from 15.6% in 2011 to zero in 2015. Doses from external exposure decreased more rapidly than those estimated from only physical decay, even in areas without decontamination (which were halved in 395 days from November 15, 2011), presumably due to the weathering effects. While the ratios of geometric mean doses immediately after decontamination to before were slightly lower than those during the same time in areas without decontamination, annual additional doses reduced by decontamination were small (0.04-0.24 mSv in the year of immediately after decontamination was completed). The results of this study showed that the levels of external exposure among Soma residents less than 16 years of age decreased during the five years after the Fukushima Daiichi nuclear power plant accident. Decontamination had only limited and temporal effects on reducing individual external doses.

  14. Filter quality of electret masks in filtering 14.6–594 nm aerosol particles: Effects of five decontamination methods

    PubMed Central

    Lin, Tzu-Hsien; Chen, Chih-Chieh; Kuo, Chung-Wen

    2017-01-01

    This study investigates the effects of five decontamination methods on the filter quality (qf) of three commercially available electret masks—N95, Gauze and Spunlace nonwoven masks. Newly developed evaluation methods, the overall filter quality (qf,o) and the qf ratio were applied to evaluate the effectiveness of decontamination methods for respirators. A scanning mobility particle sizer is utilized to measure the concentration of polydispersed particles with diameter 14.6–594 nm. The penetration of particles and pressure drop (Δp) through the mask are used to determine qf and qf,o. Experimental results reveal that the most penetrating particle size (MPS) for the pre-decontaminated N95, Gauze and Spunlace masks were 118 nm, 461 nm and 279 nm, respectively, and the respective penetration rates were 2.6%, 23.2% and 70.0%. The Δp through the pretreated N95 masks was 9.2 mm H2O at the breathing flow rate of heavy-duty workers, exceeding the Δp values obtained through Gauze and Spunlace masks. Decontamination increased the sizes of the most penetrating particles, changing the qf values of all of the masks: qf fell as particle size increased because the penetration increased. Bleach increased the Δp of N95, but destroyed the Gauze mask. However, the use of an autoclave reduces the Δp values of both the N95 and the Gauze mask. Neither the rice cooker nor ethanol altered the Δp of the Gauze mask. Chemical decontamination methods reduced the qf,o values for the three electret masks. The value of qf,o for PM0.1 exceeded that for PM0.1–0.6, because particles smaller than 100 nm had lower penetration, resulting in a better qf for a given pressure drop. The values of qf,o, particularly for PM0.1, reveal that for the tested treatments and masks, physical decontamination methods are less destructive to the filter than chemical methods. Nevertheless, when purchasing new or reusing FFRs, penetration should be regarded as the priority. PMID:29023492

  15. Charged Particles Kill Pathogens and Round Up Dust

    NASA Technical Reports Server (NTRS)

    2015-01-01

    To keep plants fresh longer in space, Marshall Space Flight Center awarded funding to the University of Wisconsin-Madison to develop a titanium oxide-based device that reduced the amount of decay-inducing ethylene gas in the air. Electrolux (now Dallas-based Aerus Holdings) furthered the technology by developing an air purification product that kills pathogens both in the atmosphere and on surfaces.

  16. Advanced worker protection system. Topical report, Phase I

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Myers, J.

    1995-07-01

    The Department of Energy (DOE) is in the process of defining the magnitude and diversity of Decontamination and Decommissioning (D&D) obligations at its numerous sites. The DOE believes that existing technologies are inadequate to solve many challenging problems such as how to decontaminate structures and equipment cost effectively, what to do with materials and wastes generated, and how to adequately protect workers and the environment. Preliminary estimates show a tremendous need for effective use of resources over a relatively long period (over 30 years). Several technologies are being investigated which can potentially reduce D&D costs while providing appropriate protection tomore » DOE workers. The DOE recognizes that traditional methods used by the EPA in hazardous waste site clean up activities are insufficient to provide the needed protection and worker productivity demanded by DOE D&D programs. As a consequence, new clothing and equipment which can adequately protect workers while providing increases in worker productivity are being sought for implementation at DOE sites. This project will result in the development of an Advanced Worker Protection System (AWPS). The AWPS will be built around a life support backpack that uses liquid air to provide cooling as well as breathing gas to the worker. The backpack will be combined with advanced protective garments, advanced liquid cooling garment, respirator, communications, and support equipment to provide improved worker protection, simplified system, maintenance, and dramatically improve worker productivity through longer duration work cycles.« less

  17. Chemical Decontamination at Browns Ferry Unit 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hartwig, Ed; Reid, Richard

    2003-09-01

    In May, 2002, the Tennessee Valley Authority's (TVA) Board of Directors approved the recovery and restart of Unit 1 at Browns Ferry Nuclear Station. As an initial step in the site characterization and restart feasibility review, a majority of the primary reactor circuit was chemically decontaminated. Close cooperation between TVA and vendor personnel resulted in project completion ahead of schedule with outstanding results. The final average decontamination factors were excellent, and the final dose rates were very low, with contact readings on most points between one and three mRem/hr. In addition to allowing TVA to do a complete and thoroughmore » job of determining the feasibility of the Unit 1 restart, the decontamination effort will greatly reduce personnel exposure during plant recovery, both whole body exposure to gamma radiation and airborne exposure during pipe replacement efforts. The implementation of lessons learned from previous decontamination work performed at Browns Ferry, as well as decontamination efforts at other plants aided greatly in the success. Specific items of note are: (1) The initial leak check of the temporary decontamination system should include ancillary systems such as the spent resin system, as well as the main circulation loop. This could save time and dose exposure if leaks are discovered before the use of such systems is required. (2) Due to the quick turnaround time from the award of contract, a vendor representative was onsite early in the project to help with engineering efforts and procedures. This aided greatly in completing preparations for the decontamination. (3) The work was performed under a single maintenance activity. This resulted in great craft and plant support. (4) The constant coverage by the site's decontamination flush directors provided timely plant support and interface. (5) The FPC system isolation and back flushing to prevent residual chemicals from being left in the FPC system should have been addressed in more detail in the pre-engineering study to prevent delays during the final system cleanup.« less

  18. The effectiveness of wastewater treatment in nuclear medicine: Performance data and radioecological considerations.

    PubMed

    Sudbrock, F; Schomäcker, K; Drzezga, A

    2017-01-01

    For planned and ongoing storage of liquid radioactive waste in a designated plant for a nuclear medicine therapy ward (decontamination system/decay system), detailed knowledge of basic parameters such as the amount of radioactivity and the necessary decay time in the plant is required. The design of the plant at the Department of Nuclear Medicine of the University of Cologne, built in 2001, was based on assumptions about the individual discharge of activity from patients, which we can now retrospectively validate. The decontamination factor of the plant is at present in the order of 10 -9 for 131 I. The annual discharges have been continuously reduced over the period of operation and are now in the region of a few kilobecquerels. This work emphasizes the high efficacy of the decontamination plant to reduce the amount of radioactivity released from the nuclear medicine ward into the environment to almost negligible levels. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Understanding Contamination; Twenty Years of Simulating Radiological Contamination

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Emily Snyder; John Drake; Ryan James

    A wide variety of simulated contamination methods have been developed by researchers to reproducibly test radiological decontamination methods. Some twenty years ago a method of non-radioactive contamination simulation was proposed at the Idaho National Laboratory (INL) that mimicked the character of radioactive cesium and zirconium contamination on stainless steel. It involved baking the contamination into the surface of the stainless steel in order to 'fix' it into a tenacious, tightly bound oxide layer. This type of contamination was particularly applicable to nuclear processing facilities (and nuclear reactors) where oxide growth and exchange of radioactive materials within the oxide layer becamemore » the predominant model for material/contaminant interaction. Additional simulation methods and their empirically derived basis (from a nuclear fuel reprocessing facility) are discussed. In the last ten years the INL, working with the Defense Advanced Research Projects Agency (DARPA) and the National Homeland Security Research Center (NHSRC), has continued to develop contamination simulation methodologies. The most notable of these newer methodologies was developed to compare the efficacy of different decontamination technologies against radiological dispersal device (RDD, 'dirty bomb') type of contamination. There are many different scenarios for how RDD contamination may be spread, but the most commonly used one at the INL involves the dispersal of an aqueous solution containing radioactive Cs-137. This method was chosen during the DARPA projects and has continued through the NHSRC series of decontamination trials and also gives a tenacious 'fixed' contamination. Much has been learned about the interaction of cesium contamination with building materials, particularly concrete, throughout these tests. The effects of porosity, cation-exchange capacity of the material and the amount of dirt and debris on the surface are very important factors. The interaction of the contaminant/substrate with the particular decontamination technology is also very important. Results of decontamination testing from hundreds of contaminated coupons have lead to certain conclusions about the contamination and the type of decontamination methods being deployed. A recent addition to the DARPA initiated methodology simulates the deposition of nuclear fallout. This contamination differs from previous tests in that it has been developed and validated purely to simulate a 'loose' type of contamination. This may represent the first time that a radiologically contaminated 'fallout' stimulant has been developed to reproducibly test decontamination methods. While no contaminant/methodology may serve as a complete example of all aspects that could be seen in the field, the study of this family of simulation methods provides insight into the nature of radiological contamination.« less

  20. Underground Transport Restoration (UTR) Operational Technology Demonstration (OTD)

    EPA Pesticide Factsheets

    This full-scale study focused on gathering sampling, decontamination (decon), waste management, and cost analysis information for the remediation of a subway system after contamination with a Bacillus anthracis (Ba) surrogate.

  1. Comparison of Decontamination Efficacy of Cleaning Solutions on a Biological Safety Cabinet Workbench Contaminated by Cyclophosphamide

    PubMed Central

    Adé, Apolline; Chauchat, Laure; Frève, Johann-François Ouellette; Gagné, Sébastien; Caron, Nicolas; Bussières, Jean-François

    2017-01-01

    Background Several studies have compared cleaning procedures for decontaminating surfaces exposed to antineoplastic drugs. All of the cleaning products tested were successful in reducing most of the antineoplastic drug quantities spilled on surfaces, but none of them completely removed residual traces. Objective To assess the efficacy of various cleaning solutions for decontaminating a biological safety cabinet workbench exposed to a defined amount of cyclophosphamide. Methods In this pilot study, specific areas of 2 biological safety cabinets (class II, type B2) were deliberately contaminated with a defined quantity of cyclophosphamide (10 μg or 107 pg). Three cleaning solutions were tested: quaternary ammonium, sodium hypochlorite 0.02%, and sodium hypochlorite 2%. After cleaning, the cyclophosphamide remaining on the areas was quantified by wipe sampling. Each cleaning solution was tested 3 times, with cleaning and wipe sampling being performed 5 times for each test. Results A total of 57 wipe samples were collected and analyzed. The average recovery efficiency was 121.690% (standard deviation 5.058%). The decontamination efficacy increased with the number of successive cleaning sessions: from 98.710% after session 1 to 99.997% after session 5 for quaternary ammonium; from 97.027% to 99.997% for sodium hypochlorite 0.02%; and from 98.008% to 100% for sodium hypochlorite 2%. Five additional cleaning sessions performed after the main study (with detergent and sodium hypochlorite 2%) were effective to complete the decontamination, leaving no detectable traces of the drug. Conclusions All of the cleaning solutions reduced contamination of biological safety cabinet workbenches exposed to a defined amount of cyclophosphamide. Quaternary ammonium and sodium hypochlorite (0.02% and 2%) had mean efficacy greater than 97% for removal of the initial quantity of the drug (107 pg) after the first cleaning session. When sodium hypochlorite 2% was used, fewer cleaning sessions were required to complete decontamination. Further studies should be conducted to identify optimal cleaning strategies to fully eliminate traces of hazardous drugs. PMID:29298999

  2. Chemical warfare agent simulants for human volunteer trials of emergency decontamination: A systematic review.

    PubMed

    James, Thomas; Wyke, Stacey; Marczylo, Tim; Collins, Samuel; Gaulton, Tom; Foxall, Kerry; Amlôt, Richard; Duarte-Davidson, Raquel

    2018-01-01

    Incidents involving the release of chemical agents can pose significant risks to public health. In such an event, emergency decontamination of affected casualties may need to be undertaken to reduce injury and possible loss of life. To ensure these methods are effective, human volunteer trials (HVTs) of decontamination protocols, using simulant contaminants, have been conducted. Simulants must be used to mimic the physicochemical properties of more harmful chemicals, while remaining non-toxic at the dose applied. This review focuses on studies that employed chemical warfare agent simulants in decontamination contexts, to identify those simulants most suitable for use in HVTs of emergency decontamination. Twenty-two simulants were identified, of which 17 were determined unsuitable for use in HVTs. The remaining simulants (n = 5) were further scrutinized for potential suitability according to toxicity, physicochemical properties and similarities to their equivalent toxic counterparts. Three suitable simulants, for use in HVTs were identified; methyl salicylate (simulant for sulphur mustard), diethyl malonate (simulant for soman) and malathion (simulant for VX or toxic industrial chemicals). All have been safely used in previous HVTs, and have a range of physicochemical properties that would allow useful inference to more toxic chemicals when employed in future studies of emergency decontamination systems. © 2017 Crown Copyright. Journal of Applied Toxicology published by John Wiley & Sons, Ltd.

  3. Impact on human health of Salmonella spp. on pork in The Netherlands and the anticipated effects of some currently proposed control strategies.

    PubMed

    Berends, B R; Van Knapen, F; Mossel, D A; Burt, S A; Snijders, J M

    1998-11-10

    The impact on human health of Salmonella spp. on pork in The Netherlands is described. Subsequently, the effects of some currently proposed control strategies in the Dutch pork production chain are evaluated and quantified with the aid of a simple mathematical model. The estimated average incidence of cases of salmonellosis in the Netherlands is about 450 cases per 100,000 person years at risk (pyar). Some special risk groups for which the risks could be quantified are (1) persons with underlying diseases, such as neoplasms or diabetes mellitus (1200 cases/100,000 pyar); (2) persons with achlorhydria or who excessively use antacids (1100 cases/100,000 pyar); (3) persons who have recently been treated with antibiotics that disturb the normal gut flora (1700 cases/100,000 pyar); (4) nurses (900 cases/100,000 pyar); (5) caterers (900 cases/100,000 pyar); (6) slaughterline personnel (1800 cases/100,000 pyar). Furthermore, it is estimated that 15% (5-25%) of all cases of salmonellosis in The Netherlands are associated with the consumption of pork. Currently, proposed control measures regarding Salmonella in pigs and on pork in The Netherlands are codes of good manufacturing practices (GMP) that, in fact, formalize recommendations that can be found in many handbooks about pig breeding and pig slaughtering. When evaluated by a mathematical model constructed for this purpose, the proposed GMP codes from farm to cutting/retail could, at best, reduce the current levels of Salmonella-positive pigs and pork by 50-60%. If pigs were bred according to the rather costly specific pathogen-free concept (SPF), the prevalence of contaminated carcasses and pork could in total be reduced by 95% or more. However, implementing GMP codes from the transport phase up to the cutting/retail phase coupled with a decontamination step at the end of the slaughterline would be just as effective as GMP in combination with breeding using the SPF-concept. It is therefore concluded that the most efficient and cost-effective way of reducing the 'Salmonella problem' entailed by the consumption of pork would be to decontaminate carcasses under the precondition that the entire production chain strictly adheres to GMP principles. Therefore, the EU should also allow for more possibilities regarding the decontamination of carcasses than is currently the case. It is also concluded that current EU regulations relying on hazard analysis of critical control points (HACCP)-inspired production in cutting plants will not be effective in reducing the prevalence of Salmonella spp. on pork. This is mainly because (1) there is currently an almost steady stream of Salmonella-positive carcasses that enter the cutting process; (2) when contaminated carcasses are being processed, further cross-contamination during working hours is unavoidable; (3) no steps in the cutting process are intentionally designed to effectively reduce the risks or consequences of cross contamination of cuts and retail-ready products.

  4. Scalable and efficient separation of hydrogen isotopes using graphene-based electrochemical pumping

    NASA Astrophysics Data System (ADS)

    Lozada-Hidalgo, M.; Zhang, S.; Hu, S.; Esfandiar, A.; Grigorieva, I. V.; Geim, A. K.

    2017-05-01

    Thousands of tons of isotopic mixtures are processed annually for heavy-water production and tritium decontamination. The existing technologies remain extremely energy intensive and require large capital investments. New approaches are needed to reduce the industry's footprint. Recently, micrometre-size crystals of graphene are shown to act as efficient sieves for hydrogen isotopes pumped through graphene electrochemically. Here we report a fully-scalable approach, using graphene obtained by chemical vapour deposition, which allows a proton-deuteron separation factor of around 8, despite cracks and imperfections. The energy consumption is projected to be orders of magnitude smaller with respect to existing technologies. A membrane based on 30 m2 of graphene, a readily accessible amount, could provide a heavy-water output comparable to that of modern plants. Even higher efficiency is expected for tritium separation. With no fundamental obstacles for scaling up, the technology's simplicity, efficiency and green credentials call for consideration by the nuclear and related industries.

  5. Development of active porous medium filters based on plasma textiles

    NASA Astrophysics Data System (ADS)

    Kuznetsov, Ivan A.; Saveliev, Alexei V.; Rasipuram, Srinivasan; Kuznetsov, Andrey V.; Brown, Alan; Jasper, Warren

    2012-05-01

    Inexpensive, flexible, washable, and durable materials that serve as antimicrobial filters and self-decontaminating fabrics are needed to provide active protection to people in areas regularly exposed to various biohazards, such as hospitals and bio research labs working with pathogens. Airlines and cruise lines need such material to combat the spread of infections. In households these materials can be used in HVAC filters to fight indoor pollution, which is especially dangerous to people suffering from asthma. Efficient filtering materials are also required in areas contaminated by other types of hazardous dust particulates, such as nuclear dust. The primary idea that guided the undertaken study is that a microplasma-generating structure can be embedded in a textile fabric to generate a plasma sheath ("plasma shield") that kills bacterial agents coming in contact with the fabric. The research resulted in the development of a plasma textile that can be used for producing new types of self-decontaminating garments, fabrics, and filter materials, capable of activating a plasma sheath that would filter, capture, and destroy any bacteriological agent deposited on its surface. This new material relies on the unique antimicrobial and catalytic properties of cold (room temperature) plasma that is benign to people and does not cause thermal damage to many polymer textiles, such as Nomex and polypropylene. The uniqueness of cold plasma as a disinfecting agent lies in the inability of bacteria to develop resistance to plasma exposure, as they can for antibiotics. Plasma textiles could thus be utilized for microbial destruction in active antimicrobial filters (for continuous decontamination and disinfection of large amounts of air) as well as in self-decontaminating surfaces and antibacterial barriers (for example, for creating local antiseptic or sterile environments around wounds and burns).

  6. Development of active porous medium filters based on plasma textiles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuznetsov, Ivan A.; Saveliev, Alexei V.; Rasipuram, Srinivasan

    2012-05-15

    Inexpensive, flexible, washable, and durable materials that serve as antimicrobial filters and self-decontaminating fabrics are needed to provide active protection to people in areas regularly exposed to various biohazards, such as hospitals and bio research labs working with pathogens. Airlines and cruise lines need such material to combat the spread of infections. In households these materials can be used in HVAC filters to fight indoor pollution, which is especially dangerous to people suffering from asthma. Efficient filtering materials are also required in areas contaminated by other types of hazardous dust particulates, such as nuclear dust. The primary idea that guidedmore » the undertaken study is that a microplasma-generating structure can be embedded in a textile fabric to generate a plasma sheath (''plasma shield'') that kills bacterial agents coming in contact with the fabric. The research resulted in the development of a plasma textile that can be used for producing new types of self-decontaminating garments, fabrics, and filter materials, capable of activating a plasma sheath that would filter, capture, and destroy any bacteriological agent deposited on its surface. This new material relies on the unique antimicrobial and catalytic properties of cold (room temperature) plasma that is benign to people and does not cause thermal damage to many polymer textiles, such as Nomex and polypropylene. The uniqueness of cold plasma as a disinfecting agent lies in the inability of bacteria to develop resistance to plasma exposure, as they can for antibiotics. Plasma textiles could thus be utilized for microbial destruction in active antimicrobial filters (for continuous decontamination and disinfection of large amounts of air) as well as in self-decontaminating surfaces and antibacterial barriers (for example, for creating local antiseptic or sterile environments around wounds and burns).« less

  7. UV Light Inactivation of Human and Plant Pathogens in Unfiltered Surface Irrigation Water

    PubMed Central

    Jones, Lisa A.; Worobo, Randy W.

    2014-01-01

    Fruit and vegetable growers continually battle plant diseases and food safety concerns. Surface water is commonly used in the production of fruits and vegetables and can harbor both human- and plant-pathogenic microorganisms that can contaminate crops when used for irrigation or other agricultural purposes. Treatment methods for surface water are currently limited, and there is a need for suitable treatment options. A liquid-processing unit that uses UV light for the decontamination of turbid juices was analyzed for its efficacy in the treatment of surface waters contaminated with bacterial or oomycete pathogens, i.e., Escherichia coli, Salmonella enterica, Listeria monocytogenes, Clavibacter michiganensis subsp. michiganensis, Pseudomonas syringae pv. tomato, and Phytophthora capsici. Five-strain cocktails of each pathogen, containing approximately 108 or 109 CFU/liter for bacteria or 104 or 105 zoospores/liter for Ph. capsici, were inoculated into aliquots of two turbid surface water irrigation sources and processed with the UV unit. Pathogens were enumerated before and after treatment. In general, as the turbidity of the water source increased, the effectiveness of the UV treatment decreased, but in all cases, 99.9% or higher inactivation was achieved. Log reductions ranged from 10.0 to 6.1 and from 5.0 to 4.2 for bacterial pathogens and Ph. capsici, respectively. PMID:24242253

  8. UV light inactivation of human and plant pathogens in unfiltered surface irrigation water.

    PubMed

    Jones, Lisa A; Worobo, Randy W; Smart, Christine D

    2014-02-01

    Fruit and vegetable growers continually battle plant diseases and food safety concerns. Surface water is commonly used in the production of fruits and vegetables and can harbor both human- and plant-pathogenic microorganisms that can contaminate crops when used for irrigation or other agricultural purposes. Treatment methods for surface water are currently limited, and there is a need for suitable treatment options. A liquid-processing unit that uses UV light for the decontamination of turbid juices was analyzed for its efficacy in the treatment of surface waters contaminated with bacterial or oomycete pathogens, i.e., Escherichia coli, Salmonella enterica, Listeria monocytogenes, Clavibacter michiganensis subsp. michiganensis, Pseudomonas syringae pv. tomato, and Phytophthora capsici. Five-strain cocktails of each pathogen, containing approximately 10(8) or 10(9) CFU/liter for bacteria or 10(4) or 10(5) zoospores/liter for Ph. capsici, were inoculated into aliquots of two turbid surface water irrigation sources and processed with the UV unit. Pathogens were enumerated before and after treatment. In general, as the turbidity of the water source increased, the effectiveness of the UV treatment decreased, but in all cases, 99.9% or higher inactivation was achieved. Log reductions ranged from 10.0 to 6.1 and from 5.0 to 4.2 for bacterial pathogens and Ph. capsici, respectively.

  9. [Decontamination of chemical warfare agents by photocatalysis].

    PubMed

    Hirakawa, Tsutomu; Mera, Nobuaki; Sano, Taizo; Negishi, Nobuaki; Takeuchi, Koji

    2009-01-01

    Photocatalysis has been widely applied to solar-energy conversion and environmental purification. Photocatalyst, typically titanium dioxide (TiO(2)), produces active oxygen species under irradiation of ultraviolet light, and can decompose not only conventional pollutants but also different types of hazardous substances at mild conditions. We have recently started the study of photocatalytic decontamination of chemical warfare agents (CWAs) under collaboration with the National Research Institute of Police Science. This article reviews environmental applications of semiconductor photocatalysis, decontamination methods for CWAs, and previous photocatalytic studies applied to CWA degradation, together with some of our results obtained with CWAs and their simulant compounds. The data indicate that photocatalysis, which may not always give a striking power, certainly helps detoxification of such hazardous compounds. Unfortunately, there are not enough data obtained with real CWAs due to the difficulty in handling. We will add more scientific data using CWAs in the near future to develop useful decontamination systems that can reduce the damage caused by possible terrorism.

  10. Environmental decontamination following occupancy of a burns patient with multiple carbapenemase-producing organisms.

    PubMed

    Garvey, M I; Bradley, C W; Jumaa, P

    2016-06-01

    Over the last decade, carbapenemase-producing organisms (CPOs) have spread worldwide, becoming a major public health concern. This article reports the authors' experience in dealing with a burns patient infected with CPOs, and the decontamination methods employed to render a burns shock room safe for re-use. The shock room was cleaned after being vacated, but environmental sampling cultured multiple CPOs. A second decontamination was undertaken comprising a detergent, steam and hypochlorite clean followed by hydrogen peroxide misting, and no CPOs were cultured after subsequent environmental sampling. A burns patient harbouring CPOs contaminates the surroundings heavily, so standard cleaning is insufficient to reduce the environmental bioburden. Copyright © 2016 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  11. Laboratory-Scale Study in Determining the Decontamination Standards for Personnel Protective Equipment Used by Homeland Defense Personnel: Evaluation of Commercial Off-the-Shelf Technologies for Decontamination of Personnel Protective Equipment-Relevant Surfaces

    DTIC Science & Technology

    2008-06-01

    Assessment of Bacillus anthracis, Bacillus subtilis, and Geobacillus stearothermophilus Spores on Indoor Surfaces Using a Hydrogen Peroxide Gas...24-25% hydrogen peroxide (CAS # 7722-84-1), and 1-1.4% acetic acid. Clorox® bleach was diluted 1/ 1 0 th with sterile distilled water. Clean Earth...Peridox TM was diluted 1/6th with sterile distilled water. The disinfectants were used within 2 hr of their preparation. 2.2 Coupon Procurement Small size

  12. Contaminated Human Remains: Transportable Decontamination - 1. Technical Readiness Level Estimate. 2. Vaccinia Virus Ionizing Radiation Inactivation in a Human Phantom. 3. Current State of Technology Relevant to Development of a Transportable System for Treatment of Contaminated Human Remains

    DTIC Science & Technology

    2011-05-30

    affect chemical agents. Therefore no change in the methods for chemical or radiological decontamination would be necessary. 14. Radiation...here is the high radiation doses do affect the ability to polymerase chain reaction methods. It appears, depending on the dose and target, these...2001) Bacillus spore inactivation methods affect detection assays. Appl Environ Microbiol. 67(8): p. 3665‐70. DeCarlos, A. and Paez, E. (1991

  13. Quarantine Regulations and the Impact of Modern Detection Methods.

    PubMed

    Martin, Robert R; Constable, Fiona; Tzanetakis, Ioannis E

    2016-08-04

    Producers worldwide need access to the best plant varieties and cultivars available to be competitive in global markets. This often means moving plants across international borders as soon as they are available. At the same time, quarantine agencies are tasked with minimizing the risk of introducing exotic pests and pathogens along with imported plant material, with the goal to protect domestic agriculture and native fauna and flora. These two drivers, the movement of more plant material and reduced risk of pathogen introduction, are at odds. Improvements in large-scale or next-generation sequencing (NGS) and bioinformatics for data analysis have resulted in improved speed and accuracy of pathogen detection that could facilitate plant trade with reduced risk of pathogen movement. There are concerns to be addressed before NGS can replace existing tools used for pathogen detection in plant quarantine and certification programs. Here, we discuss the advantages and possible pitfalls of this technology for meeting the needs of plant quarantine and certification.

  14. Antimicrobial photodisinfection with Zn(II) phthalocyanine adsorbed on TiO2 upon UVA and red irradiation

    NASA Astrophysics Data System (ADS)

    Mantareva, Vanya; Eneva, Ivelina; Kussovski, Vesselin; Borisova, Ekaterina; Angelov, Ivan

    2015-01-01

    The light exposure on a daily basis has been well accepted as a competitive method for decontamination of wastewater. The catalytic properties of TiO2 offer a great potential to reduce the transmission of pathogens in the environment. Although the titanium dioxide shows high activity against pathogens, its general usage in water cleaning is limited due to the insufficient excitation natural light (about 3% of the solar spectrum). A hydrophobic dodecylpyridyloxy Zn(II)-phthalocyanine with four peripheral hydrocarbon chains of C12 (ZnPcDo) was immobilized on a photocatalyst TiO2 anatase (P25). The resulted greenish colored nanoparticles of phthalocyanine were characterized by the means of absorption, fluorescence and infrared spectroscopy. The laser scanning confocal fluorescence microscopy was used to visualize the phthalocyanine dye by the red fluorescence emission (650 - 740 nm). The intensive Q-band in the far red visible spectral region (~ 690 nm) suggested a monomeric state of phthalocyanine on TiO2 nanoparticles. Two pathogenic bacterial strains (methicillin-resistant Staphylococcus aureus - MRSA and Salmonella enteritidis) associated with wastewater were photoinactivated with the suspension of the particles. The effective photoinactivation was observed with 1 g.L-1 TiO2 anatase at irradiation with UVA 364 nm as with UVA 364 nm and LED 643 nm. The gram-negative Salmonella enteritidis was fully photoinactivated with ZnPcDo-TiO2 and TiO2 alone at UVA 346 nm and at irradiation with two light sources (364 nm + 643 nm). The proposed conjugate appears as an useful composite material for antibacterial disinfection.

  15. Some Like It Hot: Heat Resistance of Escherichia coli in Food

    PubMed Central

    Li, Hui; Gänzle, Michael

    2016-01-01

    Heat treatment and cooking are common interventions for reducing the numbers of vegetative cells and eliminating pathogenic microorganisms in food. Current cooking method requires the internal temperature of beef patties to reach 71°C. However, some pathogenic Escherichia coli such as the beef isolate E. coli AW 1.7 are extremely heat resistant, questioning its inactivation by current heat interventions in beef processing. To optimize the conditions of heat treatment for effective decontaminations of pathogenic E. coli strains, sufficient estimations, and explanations are necessary on mechanisms of heat resistance of target strains. The heat resistance of E. coli depends on the variability of strains and properties of food formulations including salt and water activity. Heat induces alterations of E. coli cells including membrane, cytoplasm, ribosome and DNA, particularly on proteins including protein misfolding and aggregations. Resistant systems of E. coli act against these alterations, mainly through gene regulations of heat response including EvgA, heat shock proteins, σE and σS, to re-fold of misfolded proteins, and achieve antagonism to heat stress. Heat resistance can also be increased by expression of key proteins of membrane and stabilization of membrane fluidity. In addition to the contributions of the outer membrane porin NmpC and overcome of osmotic stress from compatible solutes, the new identified genomic island locus of heat resistant performs a critical role to these highly heat resistant strains. This review aims to provide an overview of current knowledge on heat resistance of E. coli, to better understand its related mechanisms and explore more effective applications of heat interventions in food industry. PMID:27857712

  16. Use of Dual Electromagnetic Radiation Technology to Reduce Salmonella and Listeria monocytogenes Risk on Cooked and Packaged Meat Products

    USDA-ARS?s Scientific Manuscript database

    Pathogenic bacteria including Salmonella and Listeria can potentially contaminate ready-to-eat meats. These bacteria compromise the safety of our food supply. The objective of this research was to develop and test new low temperature pasteurization technology for packaged or thermally sensitive food...

  17. Comparison of UV-C and Pulsed UV Light Treatments for Reduction of Salmonella, Listeria monocytogenes, and Enterohemorrhagic Escherichia coli on Eggs.

    PubMed

    Holck, Askild L; Liland, Kristian H; Drømtorp, Signe M; Carlehög, Mats; McLEOD, Anette

    2018-01-01

    Ten percent of all strong-evidence foodborne outbreaks in the European Union are caused by Salmonella related to eggs and egg products. UV light may be used to decontaminate egg surfaces and reduce the risk of human salmonellosis infections. The efficiency of continuous UV-C (254 nm) and pulsed UV light for reducing the viability of Salmonella Enteritidis, Listeria monocytogenes, and enterohemorrhagic Escherichia coli on eggs was thoroughly compared. Bacterial cells were exposed to UV-C light at fluences from 0.05 to 3.0 J/cm 2 (10 mW/cm 2 , for 5 to 300 s) and pulsed UV light at fluences from 1.25 to 18.0 J/cm 2 , resulting in reductions ranging from 1.6 to 3.8 log, depending on conditions used. Using UV-C light, it was possible to achieve higher reductions at lower fluences compared with pulsed UV light. When Salmonella was stacked on a small area or shielded in feces, the pulsed UV light seemed to have a higher penetration capacity and gave higher bacterial reductions. Microscopy imaging and attempts to contaminate the interior of the eggs with Salmonella through the eggshell demonstrated that the integrity of the eggshell was maintained after UV light treatments. Only minor sensory changes were reported by panelists when the highest UV doses were used. UV-C and pulsed UV light treatments appear to be useful decontamination technologies that can be implemented in continuous processing.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Laughlin, Gary L.

    The International, Homeland, and Nuclear Security (IHNS) Program Management Unit (PMU) oversees a broad portfolio of Sandia’s programs in areas ranging from global nuclear security to critical asset protection. We use science and technology, innovative research, and global engagement to counter threats, reduce dangers, and respond to disasters. The PMU draws on the skills of scientists and engineers from across Sandia. Our programs focus on protecting US government installations, safeguarding nuclear weapons and materials, facilitating nonproliferation activities, securing infrastructures, countering chemical and biological dangers, and reducing the risk of terrorist threats. We conduct research in risk and threat analysis, monitoringmore » and detection, decontamination and recovery, and situational awareness. We develop technologies for verifying arms control agreements, neutralizing dangerous materials, detecting intruders, and strengthening resiliency. Our programs use Sandia’s High-Performance Computing resources for predictive modeling and simulation of interdependent systems, for modeling dynamic threats and forecasting adaptive behavior, and for enabling decision support and processing large cyber data streams. In this report, we highlight four advanced computation projects that illustrate the breadth of the IHNS mission space.« less

  19. Improving microbiological safety and quality characteristics of wheat and barley by high voltage atmospheric cold plasma closed processing.

    PubMed

    Los, Agata; Ziuzina, Dana; Akkermans, Simen; Boehm, Daniela; Cullen, Patrick J; Van Impe, Jan; Bourke, Paula

    2018-04-01

    Contamination of cereal grains as a key global food resource with insects or microorganisms is a persistent concern for the grain industry due to irreversible damage to quality and safety characteristics and economic losses. Atmospheric cold plasma presents an alternative to conventional grain decontamination methods owing to the high antimicrobial potential of reactive species generated during the treatment, but effects against product specific microflora are required to understand how to optimally develop this approach for grains. This work investigated the influence of ACP processing parameters for both cereal grain decontamination and grain quality as important criteria for grain or seed use. A high voltage (HV) (80 kV) dielectric barrier discharge (DBD) closed system was used to assess the potential for control of native microflora and pathogenic bacterial and fungal challenge microorganisms, in tandem with effects on grain functional properties. Response surface modelling of experimental data probed the key factors in relation to microbial control and seed germination promotion. The maximal reductions of barley background microbiota were 2.4 and 2.1 log 10  CFU/g and of wheat - 1.5 and 2.5 log 10  CFU/g for bacteria and fungi, respectively, which required direct treatment for 20 min followed by a 24 h sealed post-treatment retention time. In the case of challenge organisms inoculated on barley grains, the highest resistance was observed for Bacillus atrophaeus endospores, which, regardless of retention time, were maximally reduced by 2.4 log 10  CFU/g after 20 min of direct treatment. The efficacy of the plasma treatment against selected microorganisms decreased in the following order: E. coli > P. verrucosum (spores) > B. atrophaeus (vegetative cells) > B. atrophaeus (endospores). The challenge microorganisms were more susceptible to ACP treatment than naturally present background microbiota. No major effect of short term plasma treatment on the retention of quality parameters was observed. Germination percentage measured after 7 days cultivation was similar for samples treated for up to 5 min, but this was decreased after 20 min of direct treatment. Overall, ACP proved effective for cereal grain decontamination, but it is noted that the diverse native micro-flora may pose greater resistance to the closed, surface decontamination approach than the individual fungal or bacterial challenges, which warrants investigation of grain microbiome responses to ACP. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Planetary quarantine. Space research and technology

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Planetary quarantine strategies for advanced spacecraft consider effects of satellite encounter, Jupiter atmosphere entry, space radiation, and cleaning and decontamination techniques on microbiological growth probability. Analytical restructuring is developed for microbial burden prediction and planetary contamination.

  1. Science Inventory Products About Land and Waste Management Research

    EPA Pesticide Factsheets

    Resources from the Science Inventory database of EPA's Office of Research and Development, as well as EPA's Science Matters journal, include research on managing contaminated sites and ground water modeling and decontamination technologies.

  2. Land and Waste Management Research Publications in the Science Inventory

    EPA Pesticide Factsheets

    Resources from the Science Inventory database of EPA's Office of Research and Development, as well as EPA's Science Matters journal, include research on managing contaminated sites and ground water modeling and decontamination technologies.

  3. Considerations for selecting personal protective equipment for hazardous materials decontamination.

    PubMed

    Lehmann, Jeff

    2002-09-01

    PPE is necessary to protect staff and to deliver rapid and efficient care to patients contaminated with HAZMAT chemicals. Planning for HAZMAT cases includes learning about the common chemicals in the area, what resources are available to care for victims, identifying a decontamination area, and providing PPE to protect employees and other patients. A customized service can be used to meet OSHA standards and reduce costs. Ongoing training will be an important part of any HAZMAT program.

  4. Decolonization in Prevention of Health Care-Associated Infections.

    PubMed

    Septimus, Edward J; Schweizer, Marin L

    2016-04-01

    Colonization with health care-associated pathogens such as Staphylococcus aureus, enterococci, Gram-negative organisms, and Clostridium difficile is associated with increased risk of infection. Decolonization is an evidence-based intervention that can be used to prevent health care-associated infections (HAIs). This review evaluates agents used for nasal topical decolonization, topical (e.g., skin) decolonization, oral decolonization, and selective digestive or oropharyngeal decontamination. Although the majority of studies performed to date have focused on S. aureus decolonization, there is increasing interest in how to apply decolonization strategies to reduce infections due to Gram-negative organisms, especially those that are multidrug resistant. Nasal topical decolonization agents reviewed include mupirocin, bacitracin, retapamulin, povidone-iodine, alcohol-based nasal antiseptic, tea tree oil, photodynamic therapy, omiganan pentahydrochloride, and lysostaphin. Mupirocin is still the gold standard agent for S. aureus nasal decolonization, but there is concern about mupirocin resistance, and alternative agents are needed. Of the other nasal decolonization agents, large clinical trials are still needed to evaluate the effectiveness of retapamulin, povidone-iodine, alcohol-based nasal antiseptic, tea tree oil, omiganan pentahydrochloride, and lysostaphin. Given inferior outcomes and increased risk of allergic dermatitis, the use of bacitracin-containing compounds cannot be recommended as a decolonization strategy. Topical decolonization agents reviewed included chlorhexidine gluconate (CHG), hexachlorophane, povidone-iodine, triclosan, and sodium hypochlorite. Of these, CHG is the skin decolonization agent that has the strongest evidence base, and sodium hypochlorite can also be recommended. CHG is associated with prevention of infections due to Gram-positive and Gram-negative organisms as well as Candida. Conversely, triclosan use is discouraged, and topical decolonization with hexachlorophane and povidone-iodine cannot be recommended at this time. There is also evidence to support use of selective digestive decontamination and selective oropharyngeal decontamination, but additional studies are needed to assess resistance to these agents, especially selection for resistance among Gram-negative organisms. The strongest evidence for decolonization is for use among surgical patients as a strategy to prevent surgical site infections. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  5. Nanoindentation of orthodontic archwires: The effect of decontamination and clinical use on hardness, elastic modulus and surface roughness.

    PubMed

    Alcock, Joseph P; Barbour, Michele E; Sandy, Jonathan R; Ireland, Anthony J

    2009-08-01

    The purpose of this research was to investigate the effects of decontamination and clinical exposure on the elastic moduli, hardness and surface roughness of two frequently used orthodontic archwires, namely 0.020in.x0.020in. heat activated (martensitic active) nickel titanium archwires and 0.019in.x0.025in. austenitic stainless steel archwires. This study was a prospective clinical trial in which 20 consecutive patients requiring an archwire change as part of their course of orthodontic fixed appliance therapy, had either a nickel titanium or stainless steel archwire fitted as deemed clinically necessary. The effect of clinical use was determined by comparing distal end cuts of the "as received" archwires before and after decontamination, with the same retrieved archwires following clinical use and decontamination. Hardness, elastic modulus and surface roughness were determined using an atomic force microscope (AFM) coupled with a nanoindenter. The results showed that the decontamination regimen and clinical use had no statistically significant effect on the nickel titanium archwires, but did have a statistically significant effect on the steel archwires. Decontamination of the steel wires significantly increased the observed surface hardness (p=0.01) and reduced the surface roughness (p=0.02). Clinical use demonstrated a statistically significant increase in the observed elastic modulus (p<0.001) and a decrease in surface roughness (p=0.001). At present it is difficult to predict the clinical significance of these statistically significant changes in archwire properties on orthodontic tooth movement.

  6. Efficacy of UV light treatment for the microbiological decontamination of chicken, associated packaging, and contact surfaces.

    PubMed

    Haughton, P N; Lyng, J G; Cronin, D A; Morgan, D J; Fanning, S; Whyte, P

    2011-04-01

    UV light was investigated for the decontamination of raw chicken, associated packaging, and contact surfaces. The UV susceptibilities of a number of Campylobacter isolates (seven Campylobacter jejuni isolates and three Campylobacter coli isolates), Escherichia coli ATCC 25922, and Salmonella enterica serovar Enteritidis ATCC 10376 in liquid media were also investigated. From an initial level of 7 log CFU/ml, no viable Campylobacter cells were detected following exposure to the most intense UV dose (0.192 J/cm(2)) in liquid media (skim milk subjected to ultrahigh-temperature treatment and diluted 1:4 with maximum recovery diluent). Maximum reductions of 4.8 and 6.2 log CFU/ml were achieved for E. coli and serovar Enteritidis, respectively, in liquid media. Considerable differences in susceptibilities were found between the Campylobacter isolates examined, with variations of up to 4 log CFU/ml being observed. UV treatment of raw chicken fillet (0.192 J/cm(2)) reduced C. jejuni, E. coli, serovar Enteritidis, total viable counts, and Enterobacteriaceae by 0.76, 0.98, 1.34, 1.76, and 1.29 log CFU/g, respectively. Following UV treatment of packaging and surface materials, reductions of up to 3.97, 4.50, and 4.20 log CFU/cm(2) were obtained for C. jejuni, E. coli, and serovar Enteritidis, respectively (P < 0.05). Overall, the color of UV-treated chicken was not significantly affected (P ≥ 0.05). The findings of this study indicate that Campylobacter is susceptible to UV technology and that differences in sensitivities exist between investigated isolates. Overall, UV could be used for improving the microbiological quality of raw chicken and for decontaminating associated packaging and surface materials.

  7. An Update on the Hazards and Risks of Forensic Anthropology, Part I: Human Remains.

    PubMed

    Roberts, Lindsey G; Dabbs, Gretchen R; Spencer, Jessica R

    2016-01-01

    This work reviews the hazards and risks of practicing forensic anthropology in North America, with a focus on pathogens encountered through contact with unpreserved human remains. Since the publication of Galloway and Snodgrass' seminal paper concerning the hazards of forensic anthropology, research has provided new information about known pathogen hazards, and regulating authorities have updated recommendations for the recognition and treatment of several infections. Additionally, forensic anthropology has gained popularity, exposing an increased number of students and practitioners to these hazards. Current data suggest many occupational exposures to blood or body fluids go unreported, especially among students, highlighting the need for this discussion. For each pathogen and associated disease, this work addresses important history, reviews routes of exposure, provides an overview of symptoms and treatments, lists decontamination procedures, and presents data on postmortem viability. Personal protection and laboratory guidelines should be established and enforced in conjunction with the consideration of these data. © 2015 American Academy of Forensic Sciences.

  8. Integrated oxide graphene based device for laser inactivation of pathogenic microorganisms

    NASA Astrophysics Data System (ADS)

    Grishkanich, Alexsandr; Ruzankina, Julia; Afanasyev, Mikhail; Paklinov, Nikita; Hafizov, Nail

    2018-02-01

    We develop device for virus disinfection of pathogenic microorganisms. Viral decontamination can be carried out due to hard ultraviolet irradiation and singlet oxygen destroying the genetic material of a virus capsid. UV rays can destroy DNA, leading to the formation of dimers of nucleic acids. This practically does not occur in tissues, tk. UV rays penetrate badly through them, however, the viral particles are small and UV can destroy their genetic material, RNA / DNA and the virus can not replicate. It is with the construction of the ultraviolet laser water disinfection system (UFLOV) based on the continuous and periodic pulsed ultraviolet laser sources (pump) binds to solve sterility and depyrogenation of water. It has been established that small doses of UV irradiation stimulate reproduction, and large doses cause the death of pathogenic microorganisms. The effect of a dose of ultraviolet is the result of photochemical action on the substance of a living bacterial cell or virion. Also complex photodynamic laser inactivation on graphene oxide is realized.

  9. Gas-permeable ethylene bags for the small scale cultivation of highly pathogenic avian influenza H5N1 and other viruses in embryonated chicken eggs.

    PubMed

    Hamilton, Sara B; Daniels, Deirdre E; Sosna, William A; Jeppesen, Eric R; Owells, Julie M; Halpern, Micah D; McCurdy, Kimberly S; Rayner, Jonathan O; Lednicky, John A

    2010-01-28

    Embryonated chicken eggs (ECE) are sometimes used for the primary isolation or passage of influenza viruses, other viruses, and certain bacteria. For small-scale experiments with pathogens that must be studied in biosafety level three (BSL3) facilities, inoculated ECE are sometimes manipulated and maintained in small egg incubators within a biosafety cabinet (BSC). To simplify the clean up and decontamination of an egg incubator in case of egg breakage, we explored whether ethylene breather bags could be used to encase ECE inoculated with pathogens. This concept was tested by determining embryo survival and examining virus yields in bagged ECE. Virus yields acceptable for many applications were attained when influenza-, alpha-, flavi-, canine distemper-, and mousepox viruses were propagated in ECE sealed within ethylene breather bags. For many small-scale applications, ethylene breather bags can be used to encase ECE inoculated with various viruses.

  10. Survival or Growth of Escherichia coli O157:H7 in a Model System of Fresh Meat Decontamination Runoff Waste Fluids and Its Resistance to Subsequent Lactic Acid Stress

    PubMed Central

    Samelis, John; Sofos, John N.; Kendall, Patricia A.; Smith, Gary C.

    2005-01-01

    A potential may exist for survival of and resistance development by Escherichia coli O157:H7 in environmental niches of meat plants applying carcass decontamination interventions. This study evaluated (i) survival or growth of acid-adapted and nonadapted E. coli O157:H7 strain ATCC 43895 in acetic acid (pH 3.6 ± 0.1) or in water (pH 7.2 ± 0.2) fresh beef decontamination runoff fluids (washings) stored at 4, 10, 15, or 25°C and (ii) resistance of cells recovered from the washings after 2 or 7 days of storage to a subsequent lactic acid (pH 3.5) stress. Corresponding cultures in sterile saline or in heat-sterilized water washings were used as controls. In acetic acid washings, acid-adapted cultures survived better than nonadapted cultures, with survival being greatest at 4°C and lowest at 25°C. The pathogen survived without growth in water washings at 4 and 10°C, while it grew by 0.8 to 2.7 log cycles at 15 and 25°C, and more in the absence of natural flora. E. coli O157:H7 cells habituated without growth in water washings at 4 or 10°C were the most sensitive to pH 3.5, while cells grown in water washings at 15 or 25°C were relatively the most resistant, irrespective of previous acid adaptation. Resistance to pH 3.5 of E. coli O157:H7 cells habituated in acetic acid washings for 7 days increased in the order 15°C > 10°C > 4°C, while at 25°C cells died off. These results indicate that growth inhibition by storage at low temperatures may be more important than competition by natural flora in inducing acid sensitization of E. coli O157:H7 in fresh meat environments. At ambient temperatures in meat plants, E. coli O157:H7 may grow to restore acid resistance, unless acid interventions are applied to inhibit growth and minimize survival of the pathogen. Acid-habituated E. coli O157:H7 at 10 to 15°C may maintain a higher acid resistance than when acid habituated at 4°C. These responses should be evaluated with fresh meat and may be useful for the optimization of decontamination programs and postdecontamination conditions of meat handling. PMID:16204542

  11. Individual external doses below the lowest reference level of 1 mSv per year five years after the 2011 Fukushima nuclear accident among all children in Soma City, Fukushima: A retrospective observational study

    PubMed Central

    Murakami, Michio; Nomura, Shuhei; Morita, Tomohiro; Nishikawa, Yoshitaka; Leppold, Claire; Kato, Shigeaki; Kami, Masahiro

    2017-01-01

    After the 2011 Fukushima Daiichi nuclear power plant accident, little information has been available on individual doses from external exposure among residents living in radioactively contaminated areas near the nuclear plant; in the present study we evaluated yearly changes in the doses from external exposure after the accident and the effects of decontamination on external exposure. This study considered all children less than 16 years of age in Soma City, Fukushima who participated in annual voluntary external exposure screening programs during the five years after the accident (n = 5,363). In total, 14,405 screening results were collected. The median participant age was eight years. The geometric mean levels of annual additional doses from external exposure attributable to the Fukushima accident, decreased each year: 0.60 mSv (range: not detectable (ND)–4.29 mSv), 0.37 mSv (range: ND–3.61 mSv), 0.22 mSv (range: ND–1.44 mSv), 0.20 mSv (range: ND–1.87 mSv), and 0.17 mSv (range: ND–0.85 mSv) in 2011, 2012, 2013, 2014, and 2015, respectively. The proportion of residents with annual additional doses from external exposure of more than 1 mSv dropped from 15.6% in 2011 to zero in 2015. Doses from external exposure decreased more rapidly than those estimated from only physical decay, even in areas without decontamination (which were halved in 395 days from November 15, 2011), presumably due to the weathering effects. While the ratios of geometric mean doses immediately after decontamination to before were slightly lower than those during the same time in areas without decontamination, annual additional doses reduced by decontamination were small (0.04–0.24 mSv in the year of immediately after decontamination was completed). The results of this study showed that the levels of external exposure among Soma residents less than 16 years of age decreased during the five years after the Fukushima Daiichi nuclear power plant accident. Decontamination had only limited and temporal effects on reducing individual external doses. PMID:28235009

  12. TiO{sub 2}-based photocatalytic disinfection of microbes in aqueous media: A review

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Laxma Reddy, P.Venkata

    The TiO{sub 2} based photocatalyst has great potential for the disinfection/inactivation of harmful pathogens (such as E.coli in aqueous media) along with its well-known usefulness on various chemical pollutants. The disinfection property of TiO{sub 2} is primarily attributed to surface generation of reactive oxygen species (ROS) as well as free metal ions formation. Furthermore, its disinfection capacity and overall performance can be significantly improved through modifications of the TiO{sub 2} material. In this review, we provide a brief survey on the effect of various TiO{sub 2} materials in the disinfection of a wide range of environmentally harmful microbial pathogens (e.g.,more » bacteria, fungi, algae, and viruses) in aqueous media. The influencing factors (such as reactor design, water chemistry, and TiO{sub 2} modifications) of such processes are discussed along with the mechanisms of such disinfection. It is believed that the combined application of disinfection and decontamination will greatly enhance the utilization of TiO{sub 2} photocatalyst as a potential alternative to conventional methods of water purification. - Highlights: • The advent of industrialization jeopardized the quality of drinking water. • TiO{sub 2} photocatalysis holds promise both in the degradation of pollutants and for disinfection. • The applicability of TiO{sub 2}-based decontamination is explored for microbial disinfection. • Here we provide a comprehensive review on titania-based photocatalysts for disinfection.« less

  13. Land, Oil Spill, and Waste Management Research Publications in the Science Inventory

    EPA Pesticide Factsheets

    Resources from the Science Inventory database of EPA's Office of Research and Development, as well as EPA's Science Matters journal, include research on managing contaminated sites and ground water modeling and decontamination technologies.

  14. Decontamination Technologies for Emerging CBRNE Agents: Scoping Study

    DTIC Science & Technology

    2014-05-01

    organophosphorus pesticides ( chlorpyrifos , diazinon, malathion) which are neurotoxins, and other pesticides (captan, folpet, tralkoxydim, chlorthalonil, 1,3...organophosphorus pesticides (OPPs), gamma radiolysis for chlorpyrifos , and bio-detoxification of pesticides such as diazinon and chlorpyrifos . For instance

  15. Possibilities of a metal surface radioactive decontamination using a pulsed CO2 laser

    NASA Astrophysics Data System (ADS)

    Milijanic, Scepan S.; Stjepanovic, Natasa N.; Trtica, Milan S.

    2000-01-01

    There is a growing interest in the laser radioactive decontamination of metal surfaces. It offers advantages over conventional methods: improved safety, reduction of secondary waste, reduced waste volume, acceptable cost. A main mechanism of cleaning in by lasers is ablation. In this work a pulsed TEA CO2 laser was used for surface cleaning, primarily in order to demonstrate that the ablation from metal surfaces with this laser is possible even with relatively low pulse energies, and secondary, that it could be competitive with other lasers because of much higher energy efficiencies. The laser pulse contains two parts, one strong and shot peak at the beginning, followed with a tail. The beam was focused onto a contaminated surface with a KBr lens. The surface was contaminated with 137Cs. Three different metals were used: stainless steel, copper and aluminum. The evaporated material was pumped out in air atmosphere and transferred to a filter. Presence of the activity on the filter was proved by a germanium detector-multichannel analyzer. Activity levels were measured by a GM counter. Calculated decontamination factors as well as collection factors have shown that ablation takes place with relatively high efficiency of decontamination. This investigation suggests that decontamination using the CO2 laser should be seriously considered.

  16. Transport and Reactivity of Decontaminants to Provide Hazard Mitigation of Chemical Warfare Agents from Materials

    DTIC Science & Technology

    2016-06-01

    Membranes .2. Neoprene, SBR, EPDM , NBR, and Natural- Rubber Versus Normal-Alkanes. J. Appl. Polym. Sci. 1991, 42 (8), 2329–2336. 24. Harogoppad, S.B...highly absorptive (e.g., tire rubber ). Absorptive materials are often more challenging to decontaminate because of the reduced accessibility of the...then aged for 60 min. During the aging period, agent mass was absorbed by a flux-based process.7 The agent-contaminated area of the panel may affect

  17. ENVIRONMENTAL TECHNOLOGY VERIFICATION: JOINT (NSF-EPA) VERIFICATION STATEMENT AND REPORT FOR TREATMENT OF WASTEWATER GENERATED DURING DECONTAMINATION ACTIVITIES - ULTRASTRIP SYSTEMS, INC., MOBILE EMERGENCY FILTRATION SYSTEM (MEFS) - 04/14/WQPC-HS

    EPA Science Inventory

    Performance verification testing of the UltraStrip Systems, Inc., Mobile Emergency Filtration System (MEFS) was conducted under EPA's Environmental Technology Verification (ETV) Program at the EPA Test and Evaluation (T&E) Facility in Cincinnati, Ohio, during November, 2003, thr...

  18. Planetary quarantine: Supporting research and technology

    NASA Technical Reports Server (NTRS)

    Taylor, D. M.

    1975-01-01

    Planetary quarantine strategies for advanced missions are described, along with natural space environment studies and post launch recontamination studies. Spacecraft cleaning and decontamination techniques and assay activities are reviewed. Teflon ribbon experiments and pyrolsis gas-liquid chromatography study are also considered.

  19. Magnetic Particle Technology

    ERIC Educational Resources Information Center

    Oliveira, Luiz C.A.; A. Rios, Rachel V.R.; Fabris, Jose D.; Lago, Rachel M.; Sapag, Karim

    2004-01-01

    An exciting laboratory environment is activated by the preparation and novel use of magnetic materials to decontaminate water through adsorption and magnetic removal of metals and organics. This uncomplicated technique is also adaptable to the possible application of adsorbents to numerous other environmental substances.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maienschein, J.L.; Garcia, F.; Garza, R.G.

    Tritium-handling apparatus has been decontaminated as part of the shutdown of the LLNL Tritium Facility. Two stainless-steel gloveboxes that had been used to process lithium deuteride-tritide (LiDT) salt were decontaminated using the Portable Cleanup System so that they could be flushed with room air through the facility ventilation system. Further surface decontamination was performed by scrubbing the interior with paper towels and ethyl alcohol or Swish{trademark}. The surface contamination, as shown by swipe surveys, was reduced from 4{times}10{sup 4}--10{sup 6} disintegrations per minute (dpm)/cm{sup 2} to 2{times}10{sup 2}--4{times}10{sup 4} dpm/cm{sup 2}. Details on the decontamination operation are provided. A seriesmore » of metal (palladium and vanadium) hydride storage beds have been drained of tritium and flushed with deuterium in order to remove as much tritium as possible. The bed draining and flushing procedure is described, and a calculational method is presented which allows estimation of the tritium remaining in a bed after it has been drained and flushed. Data on specific bed draining and flushing are given.« less

  1. Persistence of ovine scrapie infectivity in a farm environment following cleaning and decontamination.

    PubMed

    Hawkins, Steve A C; Simmons, Hugh A; Gough, Kevin C; Maddison, Ben C

    2015-01-24

    Scrapie of sheep/goats and chronic wasting disease of deer/elk are contagious prion diseases where environmental reservoirs are directly implicated in the transmission of disease. In this study, the effectiveness of recommended scrapie farm decontamination regimens was evaluated by a sheep bioassay using buildings naturally contaminated with scrapie. Pens within a farm building were treated with either 20,000 parts per million free chorine solution for one hour or were treated with the same but were followed by painting and full re-galvanisation or replacement of metalwork within the pen. Scrapie susceptible lambs of the PRNP genotype VRQ/VRQ were reared within these pens and their scrapie status was monitored by recto-anal mucosa-associated lymphoid tissue. All animals became infected over an 18-month period, even in the pen that had been subject to the most stringent decontamination process. These data suggest that recommended current guidelines for the decontamination of farm buildings following outbreaks of scrapie do little to reduce the titre of infectious scrapie material and that environmental recontamination could also be an issue associated with these premises. British Veterinary Association.

  2. Nonthermal physical technologies to decontaminate and extend the shelf-life of fruits and vegetables: Trends aiming at quality and safety.

    PubMed

    Pinela, José; Ferreira, Isabel C F R

    2017-07-03

    Minimally processed fruits and vegetables are one of the major growing sectors in food industry. This growing demand for healthy and convenient foods with fresh-like properties is accompanied by concerns surrounding efficacy of the available sanitizing methods to appropriately deal with food-borne diseases. In fact, chemical sanitizers do not provide an efficient microbial reduction, besides being perceived negatively by the consumers, dangerous for human health, and harmful to the environment, and the conventional thermal treatments may negatively affect physical, nutritional, or bioactive properties of these perishable foods. For these reasons, the industry is investigating alternative nonthermal physical technologies, namely innovative packaging systems, ionizing and ultraviolet radiation, pulsed light, high-power ultrasound, cold plasma, high hydrostatic pressure, and dense phase carbon dioxide, as well as possible combinations between them or with other preservation factors (hurdles). This review discusses the potential of these novel or emerging technologies for decontamination and shelf-life extension of fresh and minimally processed fruits and vegetables. Advantages, limitations, and challenges related to its use in this sector are also highlighted.

  3. Evaluation of Commercially-Available Equipment for the ...

    EPA Pesticide Factsheets

    Report The Underground Transport Restoration (UTR) project is an inter-agency effort. This effort aims to improve the capability for transit systems to quickly and efficiently recover from a biological contamination incident by refining existing methods, tools and protocols for characterization, clean-up, and clearance of contamination in physical structures (i.e., tunnels, stations) and rolling stock (i.e., subway trains). The aim was to evaluate existing sampling, characterization, and decontamination technologies through experimentation, table-top exercises and operational demonstrations to develop guidance and decision frameworks and support tools through interactions of local, state and federal partners. In this investigation, a survey of commercially-available or fielded equipment was conducted and resulted in three pieces of identified equipment that could be used or rapidly modified for use in dispensing liquid chemicals to decontaminate surfaces following a biological contamination incident. documenting lab-scale testing, field-scale testing, and an equipment demonstration of commercial equipment used to decontaminate subway infrastructure following a biological incident.

  4. Control of human pathogenic Yersinia enterocolitica in minced meat: Comparative analysis of different interventions using a risk assessment approach.

    PubMed

    Van Damme, I; De Zutter, L; Jacxsens, L; Nauta, M J

    2017-06-01

    This study aimed to evaluate the effect of different processing scenarios along the farm-to-fork chain on the contamination of minced pork with human pathogenic Y. enterocolitica. A modular process risk model (MPRM) was used to perform the assessment of the concentrations of pathogenic Y. enterocolitica in minced meat produced in industrial meat processing plants. The model described the production of minced pork starting from the contamination of pig carcasses with pathogenic Y. enterocolitica just before chilling. The endpoints of the assessment were (i) the proportion of 0.5 kg minced meat packages that contained pathogenic Y. enterocolitica and (ii) the proportion of 0.5 kg minced meat packages that contained more than 10³ pathogenic Y. enterocolitica at the end of storage, just before consumption of raw pork or preparation. Comparing alternative scenarios to the baseline model showed that the initial contamination and different decontamination procedures of carcasses have an important effect on the proportion of highly contaminated minced meat packages at the end of storage. The addition of pork cheeks and minimal quantities of tonsillar tissue into minced meat also had a large effect on the endpoint estimate. Finally, storage time and temperature at consumer level strongly influenced the number of highly contaminated packages. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Applying Crowd Psychology to Develop Recommendations for the Management of Mass Decontamination

    PubMed Central

    Drury, John; Rubin, G. James; Williams, Richard; Amlôt, Richard

    2015-01-01

    Mass decontamination is a public health intervention employed by emergency responders following a chemical, biological, or radiological release. It involves a crowd of people whose interactions with each other and with the emergency responders managing the incident are likely to affect the success of the decontamination process. The way in which members of the public collectively experience decontamination is likely to affect their behavior and hence is crucial to the success of the decontamination process. Consequently, responders and the responsible authorities need to understand crowd psychology during mass emergencies and disasters. Recently, the social identity approach to crowd psychology has been applied to explain public perceptions and behavior during mass emergencies. This approach emphasizes that crowd events are characteristically intergroup encounters, in which the behavior of one group can affect the perceptions and behavior of another. We summarize the results from a program of research in which the social identity approach was applied to develop and test recommendations for the management of mass decontamination. The findings from this program of research show that (1) responders' perceptions of crowd behavior matter; (2) participants value greater communication and this affects their compliance; and (3) social identity processes explain the relationship between effective responder communication and relevant outcome variables, such as public compliance, public cooperation, and public anxiety. Based on this program of research, we recommend 4 responder management strategies that focus on increasing public compliance, increasing orderly and cooperative behavior among members of the public, reducing public anxiety, and respecting public needs for privacy. PMID:25812428

  6. Applying crowd psychology to develop recommendations for the management of mass decontamination.

    PubMed

    Carter, Holly; Drury, John; Rubin, G James; Williams, Richard; Amlôt, Richard

    2015-01-01

    Mass decontamination is a public health intervention employed by emergency responders following a chemical, biological, or radiological release. It involves a crowd of people whose interactions with each other and with the emergency responders managing the incident are likely to affect the success of the decontamination process. The way in which members of the public collectively experience decontamination is likely to affect their behavior and hence is crucial to the success of the decontamination process. Consequently, responders and the responsible authorities need to understand crowd psychology during mass emergencies and disasters. Recently, the social identity approach to crowd psychology has been applied to explain public perceptions and behavior during mass emergencies. This approach emphasizes that crowd events are characteristically intergroup encounters, in which the behavior of one group can affect the perceptions and behavior of another. We summarize the results from a program of research in which the social identity approach was applied to develop and test recommendations for the management of mass decontamination. The findings from this program of research show that (1) responders' perceptions of crowd behavior matter; (2) participants value greater communication and this affects their compliance; and (3) social identity processes explain the relationship between effective responder communication and relevant outcome variables, such as public compliance, public cooperation, and public anxiety. Based on this program of research, we recommend 4 responder management strategies that focus on increasing public compliance, increasing orderly and cooperative behavior among members of the public, reducing public anxiety, and respecting public needs for privacy.

  7. New Proof-of-Concept in Viral Inactivation: Virucidal Efficacy of 405 nm Light Against Feline Calicivirus as a Model for Norovirus Decontamination.

    PubMed

    Tomb, Rachael M; Maclean, Michelle; Coia, John E; Graham, Elizabeth; McDonald, Michael; Atreya, Chintamani D; MacGregor, Scott J; Anderson, John G

    2017-06-01

    The requirement for novel decontamination technologies for use in hospitals is ever present. One such system uses 405 nm visible light to inactivate microorganisms via ROS-generated oxidative damage. Although effective for bacterial and fungal inactivation, little is known about the virucidal effects of 405 nm light. Norovirus (NoV) gastroenteritis outbreaks often occur in the clinical setting, and this study was designed to investigate potential inactivation effects of 405 nm light on the NoV surrogate, feline calicivirus (FCV). FCV was exposed to 405 nm light whilst suspended in minimal and organically-rich media to establish the virucidal efficacy and the effect biologically-relevant material may play in viral susceptibility. Antiviral activity was successfully demonstrated with a 4 Log 10 (99.99%) reduction in infectivity when suspended in minimal media evident after a dose of 2.8 kJ cm -2 . FCV exposed in artificial faeces, artificial saliva, blood plasma and other organically rich media exhibited an equivalent level of inactivation using between 50-85% less dose of the light, indicating enhanced inactivation when the virus is present in organically-rich biologically-relevant media. Further research in this area could aid in the development of 405 nm light technology for effective NoV decontamination within the hospital environment.

  8. TOXICITY-BASED CHEMICAL AGENT DETECTION SYSTEMS: CONTINUOUS MONITOR AND EXPOSURE HISTORY

    EPA Science Inventory

    This project will develop and characterize chemical agent detection systems that will provide broad toxicological screening information to first responders and building decontamination personnel. The primary goal for this technology is to detect the presence of airborne chemic...

  9. Decontamination of foods by cold plasma

    USDA-ARS?s Scientific Manuscript database

    Cold plasma is a novel nonthermal food processing technology for meats, poultry, fruits, and vegetables. This flexible sanitizing method uses electricity and a carrier gas, such as air, oxygen, nitrogen, or helium to inactivate microbes without the use of conventional antimicrobial chemical agents. ...

  10. Cold plasma decontamination of foods

    USDA-ARS?s Scientific Manuscript database

    Cold plasma is a novel nonthermal food processing technology which uses energetic, reactive gases to inactivate contaminating microbes on meats, poultry and fruits and vegetables. This flexible sanitizing method uses electricity and a carrier gas such as air, oxygen, nitrogen or helium; antimicrobi...

  11. DEMONSTRATION BULLETIN: THE PLASMA CENTRIFUGAL FURNACE RETECH, INC.

    EPA Science Inventory

    The plasma centrifugal furnace is a thermal technology which uses the heat generated from a plasma torch to decontaminate metal and organic contaminated waste. This is accomplished by melting metal-bearing solids and, in the process, thermally destroying organic contaminants. The...

  12. Investigation of gaseous ozone for MRSA decontamination of hospital side-rooms.

    PubMed

    Berrington, A W; Pedler, S J

    1998-09-01

    A domestic, gaseous ozone generator was investigated for use in the decontamination of hospital side-rooms that have housed patients colonized with methicillin-resistant Staphylococcus aureus (MRSA). Three models of bacterial contamination were used. These were exposed to ozone generation in a standard hospital side-room for 4 and 7 h. A methicillin-sensitive and a methicillin-resistant strain of S. aureus were compared. Ozone concentrations of 0.14 ppm were reached, levels which are sufficient to cause mild pulmonary toxicity. Bacterial counts were reduced in the vicinity of the gas generator in most instances, but the effect elsewhere in the room was, at best, limited. MRSA appeared more resistant to the effects of ozone than methicillin-sensitive S. aureus. We conclude that the device tested would be inadequate for the decontamination of such hospital side-rooms.

  13. New perspective on functional capabilities of microbiome associated with spacecraft assembly facilities

    NASA Astrophysics Data System (ADS)

    Vaishampayan, Parag

    2016-07-01

    In compliance with Planetary Protection policy, NASA monitors the total microbial burden of spacecraft and associated environments as a means for minimizing forward contamination. Despite numerous characterizations of microbial populations in spacecraft assembly cleanrooms, understanding the metabolic traits responsible for their persistence and survival remains a significant challenge. The principal objective of this study is to establish functional traits by exploring the entire gene content (metagenome) of the cleanroom microbial community. DNA-based techniques are incapable of distinguishing viable microorganisms from dead microbial cells in samples. Consequently, metagenomic analyses based on total environmental DNA extracts do not render a meaningful understanding of the metabolic and/or functional characteristics of living microorganisms in cleanrooms. A molecular viability marker was applied to samples collected from a cleanroom facility, and subsequent metagenomic sequencing experiments showed considerable differences between the resulting viable-only and total microbiomes. Nevertheless, analyses of sequence abundance suggested that the viable microbiome was influenced by both the human microbiome and the ambient ecosystem external to the facility, which resulted in a complex community profile. Also detected were the first viral signatures ever retrieved from a cleanroom facility: the genomes of human cyclovirus 7078A and Propionibacterium phage P14.4. We also wanted to evaluate if the strict cleaning and decontamination procedures selectively favor survival and growth of hardy microrganisms, such as pathogens. Three geographically distinct cleanrooms were sampled during the assembly of three NASA spacecraft: Dawn, Phoenix, and Mars Science Laboratory. Potential pathogens and their corresponding virulence factors were present in all the samples. Decreased microbial and pathogenic diversity during spacecraft assembly, compared to before and after, indicates that decontamination and preventative measures were effective and well implemented. The findings presented here, as well as the innovative methods that enabled their discovery, promise to have profound implications for the design and interpretation of ongoing and future studies in cleanrooms, indoor environments, and potential future human missions to Mars.

  14. Technologies for reducing sludge production in wastewater treatment plants: State of the art.

    PubMed

    Wang, Qilin; Wei, Wei; Gong, Yanyan; Yu, Qiming; Li, Qin; Sun, Jing; Yuan, Zhiguo

    2017-06-01

    This review presents the state-of-the-art sludge reduction technologies applied in both wastewater and sludge treatment lines. They include chemical, mechanical, thermal, electrical treatment, addition of chemical un-coupler, and predation of protozoa/metazoa in wastewater treatment line, and physical, chemical and biological pretreatment in sludge treatment line. Emphasis was put on their effect on sludge reduction performance, with 10% sludge reduction to zero sludge production in wastewater treatment line and enhanced TS (total solids) or volatile solids removal of 5-40% in sludge treatment line. Free nitrous acid (FNA) technology seems good in wastewater treatment line but it is only under the lab-scale trial. In sludge treatment line, thermal, ultrasonic (<4400kJ/kg TS), FNA pretreatment and temperature-phased anaerobic digestion (TPAD) are promising if pathogen inactivation is not a concern. However, thermal pretreatment and TPAD are superior to other pretreatment technologies when pathogen inactivation is required. The new wastewater treatment processes including SANI®, high-rate activated sludge coupled autotrophic nitrogen removal and anaerobic membrane bioreactor coupled autotrophic nitrogen removal also have a great potential to reduce sludge production. In the future, an effort should be put on the effect of sludge reduction technologies on the removal of organic micropollutants and heavy metals. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Evaluation of a microwave based reactor for the treatment of blackwater sludge

    PubMed Central

    Mawioo, Peter M.; Rweyemamu, Audax; Garcia, Hector A.; Hooijmans, Christine M.; Brdjanovic, Damir

    2016-01-01

    A laboratory-scale microwave (MW) unit was applied to treat fresh blackwater sludge that represented fecal sludge (FS) produced at heavily used toilet facilities. The sludge was exposed to MW irradiation at different power levels and for various durations. Variables such as sludge volume and pathogen reduction were observed. The results demonstrated that the MW is a rapid and efficient technology that can reduce the sludge volume by over 70% in these experimental conditions. The concentration of bacterial pathogenic indicator E. coli also decreased to below the analytical detection levels. Furthermore, the results indicated that the MW operational conditions including radiation power and contact time can be varied to achieve the desired sludge volume and pathogen reduction. MW technology can be further explored for the potential scaling-up as an option for rapid treatment of FS from intensively used sanitation facilities such as in emergency situations. PMID:26799809

  16. Reduction of Clostridium Difficile and vancomycin-resistant Enterococcus contamination of environmental surfaces after an intervention to improve cleaning methods

    PubMed Central

    Eckstein, Brittany C; Adams, Daniel A; Eckstein, Elizabeth C; Rao, Agam; Sethi, Ajay K; Yadavalli, Gopala K; Donskey, Curtis J

    2007-01-01

    Background Contaminated environmental surfaces may play an important role in transmission of some healthcare-associated pathogens. In this study, we assessed the adequacy of cleaning practices in rooms of patients with Clostridium difficile-associated diarrhea (CDAD) and vancomycin-resistant Enterococcus (VRE) colonization or infection and examined whether an intervention would result in improved decontamination of surfaces. Methods During a 6-week period, we cultured commonly touched surfaces (i.e. bedrails, telephones, call buttons, door knobs, toilet seats, and bedside tables) in rooms of patients with CDAD and VRE colonization or infection before and after housekeeping cleaning, and again after disinfection with 10% bleach performed by the research staff. After the housekeeping staff received education and feedback, additional cultures were collected before and after housekeeping cleaning during a 10-week follow-up period. Results Of the 17 rooms of patients with VRE colonization or infection, 16 (94%) had one or more positive environmental cultures before cleaning versus 12 (71%) after housekeeping cleaning (p = 0.125), whereas none had positive cultures after bleach disinfection by the research staff (p < 0.001). Of the 9 rooms of patients with CDAD, 100% had positive cultures prior to cleaning versus 7 (78%) after housekeeping cleaning (p = 0.50), whereas only 1 (11%) had positive cultures after bleach disinfection by research staff (p = 0.031). After an educational intervention, rates of environmental contamination after housekeeping cleaning were significantly reduced. Conclusion Our findings provide additional evidence that simple educational interventions directed at housekeeping staff can result in improved decontamination of environmental surfaces. Such interventions should include efforts to monitor cleaning and disinfection practices and provide feedback to the housekeeping staff. PMID:17584935

  17. Technology and equipment based on induction melters with ``cold'' crucible for reprocessing active metal waste

    NASA Astrophysics Data System (ADS)

    Pastushkov, V. G.; Molchanov, A. V.; Serebryakov, V. P.; Smelova, T. V.; Shestoperov, I. N.

    2000-07-01

    The paper discusses specific features of technology, equipment and control of a single stage RAMW decontamination and melting process in an induction furnace equipped with a "cold" crucible. The calculated and experimental data are given on melting high activity level stainless steel and Zr simulating high activity level metal waste. The work is under way in SSC RF VNIINM.

  18. An evaluation of varying protocols for high-level disinfection of flexible fiberoptic laryngoscopes.

    PubMed

    Liming, Bryan; Funnell, Ian; Jones, Anthony; Demons, Samandra; Marshall, Kathryn; Harsha, Wayne

    2014-11-01

    The use of flexible fiberoptic laryngoscopes (FFLs) is ubiquitous in otolaryngology practices. As with any medical device, there exists a small risk for transmission of pathogenic microorganisms between patients, necessitating high-level decontamination between uses. Most of the literature to date has studied channeled scopes such as those used in esophagogastroduodenoscopy and colonoscopy. A recent study of nonchanneled flexible laryngoscopes suggested that current high-level decontamination practices in use at some institutions, including ours, may be overly aggressive. We sought to evaluate and compare the efficacy of varying techniques of high-level disinfection of FFLs. FFLs were used in routine clinical encounters and then disinfected with a variety of techniques. The FFLs were then cultured for bacteria and fungi, and the rates of positive cultures were compared between the techniques and the controls. In this study, we took FFLs following use in routine clinical practice and disinfected them using one of eight decontamination protocols. We compared the bacterial and fungal culture results to positive and negative controls. We demonstrated that each of the eight cleaning protocols was statistically efficacious at removing bacterial contamination. Our results for fungal cultures did not reach statistical significance. Using in vitro inoculation of FFLs, this study demonstrated that quicker and more cost-effective practices are equally efficacious to more time-consuming and expensive techniques with regard to bacterial contamination of FFLs. NA © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  19. MINIMIZING DECOMPOSITION OF VAPORIZED HYDROGEN PEROXIDE IN CLEAN GALVANIZED STEEL DUCTING: IMPLICATIONS FOR BIOLOGICAL DECONTAMINATION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Verce, M F; Jayaraman, B; Ford, T D

    2007-09-07

    This work examined the behavior of vaporous hydrogen peroxide (VHP) in clean, room-scale galvanized steel (GS) and polyvinylchloride-coated steel air ducts, to understand how it might be used to decontaminate larger ventilation systems. VHP injected into the GS duct decreased in concentration along the length of the duct, whereas VHP concentrations in the polyvinylchloride coated duct remained essentially constant, suggesting that VHP decomposed at the GS surface. However, decomposition was reduced at lower temperatures ({approx} 22 C) and higher flow rates ({approx} 80 actual cubic meter per hour). A computational fluid dynamics model incorporating reactive transport was used to estimatemore » surface VHP concentrations where contamination is likely to reside, and also showed how bends encourage VHP decomposition. Use of G. stearothermophilus indicators, in conjunction with model estimates, indicated that a concentration-contact time of {approx} 100 mg/L H{sub 2}O{sub 2}(g){center_dot}min was required to achieve a 6 log reduction of indicator spores in clean GS duct, at 30 C. When VHP is selected for building decontamination, this work suggests the most efficacious strategy may be to decontaminate GS ducting separately from the rest of the building, as opposed to a single decontamination event in which the ventilation system is used to distribute VHP throughout the entire building.« less

  20. Recent advances in cellulose and chitosan based membranes for water purification: A concise review.

    PubMed

    Thakur, Vijay Kumar; Voicu, Stefan Ioan

    2016-08-01

    Recently membrane technology has emerged as a new promising and pervasive technology due to its innate advantages over traditional technologies such as adsorption, distillation and extraction. In this article, some of the recent advances in developing polymeric composite membrane materials for water purification from natural polysaccharide based polymers namely cellulose derivatives and chitosan are concisely reviewed. The impact of human social, demographic and industrial evolution along with expansion through environment has significantly affected the quality of water by pollution with large quantities of pesticides, minerals, drugs or other residues. At the forefront of decontamination and purification techniques, we found the membrane materials from polymers as a potential alternative. In an attempt to reduce the number of technical polymers widely used in the preparation of membranes, many researchers have reported new solutions for desalination or retention of organic yeasts, based on bio renewable polymers like cellulose derivatives and chitosan. These realizations are presented and discussed in terms of the most important parameters of membrane separation especially water flux and retention in this article. Published by Elsevier Ltd.

  1. Planetary Quarantine Annual Review, Space Technology and Research, July 1971 - July 1972

    NASA Technical Reports Server (NTRS)

    1973-01-01

    The effects of planetary quarantine constraints are assessed for advanced missions and unmanned planetary sample return missions. Considered are natural space environment factors, post launch recontamination effects, spacecraft microbial burden estimation and prediction, and spacecraft cleaning and decontamination techniques.

  2. A PORTABLE MICROREACTOR SYSTEM TO SYNTHESIZE HYDROGEN PEROXIDE - PHASE I

    EPA Science Inventory

    In the event that vehicles of buildings become contaminated by hazardous chemical or biological materials, a well-studied and effective decontaminant is hydrogen peroxide vapor (HPV).  Unfortunately, the current technology for generating HPV requires 35 weight percent hydro...

  3. The percutaneous toxicokinetics of Sulphur mustard in a damaged skin porcine model and the evaluation of WoundStat™ as a topical decontaminant.

    PubMed

    Hall, Charlotte A; Lydon, Helen L; Dalton, Christopher H; Chipman, J Kevin; Graham, John S; Chilcott, Robert P

    2017-09-01

    This study used a damaged skin, porcine model to evaluate the in vivo efficacy of WoundStat™ for decontamination of superficial (non-haemorrhaging), sulphur mustard-contaminated wounds. The dorsal skin of 12 female pigs was subjected to controlled physical damage and exposed to 10 μL 14 C-radiolabelled sulphur mustard ( 14 C-SM). Animals were randomly assigned to either a control or a treatment group. In the latter, WoundStat™ was applied 30 s post exposure and left in situ for 1 h. Skin lesion progression and decontaminant efficacy were quantified over 6 h using a range of biophysical measurements. Skin, blood and organ samples were taken post mortem for histopathological assessment, 14 C-SM distribution and toxicokinetic analyses. Application of SM to damaged skin without decontamination was rapidly followed by advanced signs of toxicity, including ulceration and decreased blood flow at the exposure site in all animals. WoundStat™ prevented ulceration and improved blood flow at the exposure site in all decontaminated animals (n = 6). Furthermore, significantly smaller quantities of 14 C-SM were detected in the blood (45% reduction), and recovered from skin (70% reduction) and skin surface swabs (99% reduction) at 6 h post-challenge. Overall, the distribution of 14 C-SM in the internal organs was similar for both groups, with the greatest concentration in the kidneys, followed by the liver and small intestine. WoundStat™ significantly reduced the amount of 14 C-SM recovered from the liver, a key organ for SM metabolism and detoxification. This study demonstrates that WoundStat™ is a suitable product for reducing the ingress and toxicity of a chemical warfare agent. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  4. Achieving Effective Risk Management Reduction Throughout Decommissioning at the Columbus Closure Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anderson, K.D.

    2006-07-01

    Nuclear facility decontamination, dismantlement, and demolition activities provide a myriad of challenges along the path to reaching a safe, effective, and compliant decommissioning. Among the challenges faced during decommissioning, is the constant management and technical effort to eliminate, mitigate, or minimize the potential of risks of radiation exposures and other hazards to the worker, the surrounding community, and the environment. Management strategies to eliminate, mitigate, or minimize risks include incorporating strong safety and As Low As Reasonably Achievable (ALARA) principles into an integrated work planning process. Technical and operational strategies may include utilizing predictive risk analysis tools to establish contaminationmore » limits for demolition and using remote handling equipment to reduce occupational and radiation exposures to workers. ECC and E2 Closure Services, LLC (Closure Services) have effectively utilized these management and technical tools to eliminate, mitigate, and reduce radiation exposures under contract to the U.S. Department of Energy (DOE) for the decontamination and decommissioning Columbus Closure Project (CCP). In particular, Closure Services achieved significant dose reduction during the dismantling, decontamination, and demolition activities for Building JN-1. Management strategies during the interior dismantlement, decontamination, and demolition of the facility demanded an integrated work planning processes that involved project disciplines. Integrated planning processes identified multiple opportunities to incorporate the use of remote handling equipment during the interior dismantling and demolition activities within areas of high radiation. Technical strategies employed predictive risk analysis tools to set upper bounding contamination limits, allowed for the radiological demolition of the building without exceeding administrative dose limits to the worker, general public, and the environment. Adhering to management and technical strategies during the dismantlement, decontamination, and demolition of Building JN-1 enabled Closure Services to achieve strong ALARA performance, maintain absolute compliance under the regulatory requirements and meeting licensing conditions for decommissioning. (authors)« less

  5. Decontamination, decommissioning, and vendor advertorial issue, 2008

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Agnihotri, Newal

    The focus of the July-August issue is on Decontamination, decommissioning, and vendor advertorials. Articles and reports in this issue include: D and D technical paper summaries; The role of nuclear power in turbulent times, by Tom Chrisopher, AREVA, NP, Inc.; Enthusiastic about new technologies, by Jack Fuller, GE Hitachi Nuclear Energy; It's important to be good citizens, by Steve Rus, Black and Veatch Corporation; Creating Jobs in the U.S., by Guy E. Chardon, ALSTOM Power; and, and, An enviroment and a community champion, by Tyler Lamberts, Entergy Nuclear Operations, Inc. The Industry Innovations article is titled Best of the bestmore » TIP achievement 2008, by Edward Conaway, STP Nuclear Operating Company.« less

  6. Reduced Set of Virulence Genes Allows High Accuracy Prediction of Bacterial Pathogenicity in Humans

    PubMed Central

    Iraola, Gregorio; Vazquez, Gustavo; Spangenberg, Lucía; Naya, Hugo

    2012-01-01

    Although there have been great advances in understanding bacterial pathogenesis, there is still a lack of integrative information about what makes a bacterium a human pathogen. The advent of high-throughput sequencing technologies has dramatically increased the amount of completed bacterial genomes, for both known human pathogenic and non-pathogenic strains; this information is now available to investigate genetic features that determine pathogenic phenotypes in bacteria. In this work we determined presence/absence patterns of different virulence-related genes among more than finished bacterial genomes from both human pathogenic and non-pathogenic strains, belonging to different taxonomic groups (i.e: Actinobacteria, Gammaproteobacteria, Firmicutes, etc.). An accuracy of 95% using a cross-fold validation scheme with in-fold feature selection is obtained when classifying human pathogens and non-pathogens. A reduced subset of highly informative genes () is presented and applied to an external validation set. The statistical model was implemented in the BacFier v1.0 software (freely available at ), that displays not only the prediction (pathogen/non-pathogen) and an associated probability for pathogenicity, but also the presence/absence vector for the analyzed genes, so it is possible to decipher the subset of virulence genes responsible for the classification on the analyzed genome. Furthermore, we discuss the biological relevance for bacterial pathogenesis of the core set of genes, corresponding to eight functional categories, all with evident and documented association with the phenotypes of interest. Also, we analyze which functional categories of virulence genes were more distinctive for pathogenicity in each taxonomic group, which seems to be a completely new kind of information and could lead to important evolutionary conclusions. PMID:22916122

  7. The percutaneous toxicokinetics of VX in a damaged skin porcine model and the evaluation of WoundStat™ as a topical decontaminant.

    PubMed

    Lydon, Helen; Hall, Charlotte; Matar, Hazem; Dalton, Christopher; Chipman, J Kevin; Graham, John S; Chilcott, Robert P

    2018-03-01

    This study used a damaged skin, porcine model to evaluate the in vivo efficacy of WoundStat™ for the decontamination of superficial, nerve agent-contaminated wounds. Anaesthetized animals were randomly assigned to either control (n = 7), no decontamination (n = 12) or WoundStat™ (n = 12) treatment groups. Pigs were exposed to a 5× LD 50 dose of neat, radiolabelled S-[2-(diisopropylamino)ethyl]-O-ethyl methyl-phosphonothioate (VX; or equivalent volume of sterile saline for the control group) via an area of superficially damaged skin on the ear. WoundStat™ was applied at 30 seconds post-exposure to assigned animals. The VX contaminant (or saline) and decontaminant remained in place for the duration of the study (up to 6 hours). Physiological parameters and signs of intoxication were recorded during the exposure period. Skin and organ samples were taken post mortem for 14 C-VX distribution analyses. Blood samples were taken periodically for toxicokinetic and whole-blood acetylcholinesterase (AChE) activity analyses. VX exposure was accompanied by a rapid decrease in AChE activity in all animals, regardless of decontamination. However, decontamination significantly improved survival rate and time and reduced the severity of signs of intoxication. In addition, the distribution of 14 C-VX in key internal organs and post mortem blood samples was significantly lower in the WoundStat™ treatment group. This study demonstrates that WoundStat™ may be a suitable medical countermeasure for increasing both survival rate and time following VX exposure. The results also suggest that AChE activity is not a useful prognostic indicator. Copyright © 2017 John Wiley & Sons, Ltd.

  8. Implant decontamination with 2% chlorhexidine during surgical peri-implantitis treatment: a randomized, double-blind, controlled trial.

    PubMed

    de Waal, Y C M; Raghoebar, G M; Meijer, H J A; Winkel, E G; van Winkelhoff, A J

    2015-09-01

    The objective of this randomized, double-blind, controlled trial was to evaluate the clinical, radiographic, and microbiological effects of implant surface decontamination with a 2% chlorhexidine (CHX) solution in comparison with a 0.12% chlorhexidine + 0.05% cetylpyridinium chloride (CPC) solution during resective surgical peri-implantitis treatment. Forty-four patients (108 implants) with peri-implantitis were treated with resective surgical treatment consisting of bone re-contouring, surface debridement and chemical decontamination, and apically repositioned flap. Patients were randomly allocated to decontamination with a 2% CHX solution (test group) or 0.12% CHX + 0.05% CPC (control group). Clinical and radiographic parameters were recorded before treatment (baseline), and at 3, 6, and 12 months after treatment. Microbiological parameters were recorded during surgery. Multilevel analysis showed no significant differences in bleeding, suppuration, probing pocket depth, and radiographic bone loss between control and test group over three follow-up measurements (3, 6, and 12 months) from baseline. Both decontamination procedures resulted in significant reductions in anaerobic bacterial counts on the implant surface, but no significant difference was noted between control and test group (mean log 3.37 ± 2.34 vs. 3.65 ± 2.87, P = 0.99). The use of a 2% CHX solution for implant surface decontamination during resective peri-implantitis therapy does not lead to improved clinical, radiographic, or microbiological results compared with a 0.12% CHX + 0.05% CPC solution. Overall, the additional use of CHX reduces anaerobic bacterial load on the implant surface better than mechanical debridement alone, but does not seem to enhance clinical treatment outcomes (ClinicalTrials.gov number NCT01852253). © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Radiocesium decontamination of a riverside in Fukushima, Japan.

    PubMed

    Nishikiori, Tatsuhiro; Suzuki, Satoshi

    2017-10-01

    Extensive decontamination measures have been implemented in the area affected by the Fukushima Dai-ichi nuclear disaster. Typical decontamination measures, such as removing topsoil of several centimeters in depth, are not suitable for rivers where contaminated sediments have been deposited. A decontamination measure was tested that considered the spatial distribution of radiocesium at the lower part of a tributary of the Abukuma River in Fukushima. The radiocesium distribution in the flood channel was vertically and horizontally highly heterogeneous. In some parts, the activity concentration was high (>10 kBq/kg for 137 Cs) even at depths of 25 cm in the sediment. This may be due to plant growth in the flood channel favoring the deposition of sediment with high activity concentration. On the basis of the radiocesium distribution, the flood channel sediment was removed to a depth of 15-35 cm, which accumulated the most radiocesium (>3.0 kBq/kg for the sum of 134 Cs and 137 Cs). The upper 5 cm of soil was removed from the dike slopes. The river bed was not decontaminated because the activity concentration was low (<1 kBq/kg) in the river bed sediment and because the water shields gamma rays emitted from the sediment. The test decontamination measure reduced the air dose rate by a factor of approximately two, demonstrating the effectiveness of our measures. Annual external doses were calculated for when this part of the dike and the flood channel is used for commuting to school and outdoor education. The doses during the activities at the test site accounted for only 1-2% of the value during daily life in the surrounding area, indicating that radiation exposure during riverside activities is limited. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. FY90 R&D Project Descriptions ESL (Engineering & Services Laboratory) Environics Division

    DTIC Science & Technology

    1989-07-01

    and Development Support for Subsurface Monitoring Technology 15 19007048 Pumping and Purging Contaminants 16 19007049 Methods for Selecting In Situ...Decontamination 40 3788VW17 Treatment of Chlorinated Organics with Aboveground Bioreactors 41 3788VW18 Improved Methods for Monitoring Fuel Biodegradation 42 2...Fluoride (HF) Dispersion Model 63 21036093 Solvent Capacity Field Test Method 64 21037097 Volatile Organic Compound (VOC) Control Technology 65 21037102

  11. Plasma Sterilization Technology for Spacecraft Applications

    NASA Technical Reports Server (NTRS)

    Fraser, S. J.; Olson, R. L.; Leavens, W. M.

    1975-01-01

    The application of plasma gas technology to sterilization and decontamination of spacecraft components is considered. Areas investigated include: effective sterilizing ranges of four separate gases; lethal constituents of a plasma environment; effectiveness of plasma against a diverse group of microorganisms; penetrating efficiency of plasmas for sterilization; and compatibility of spacecraft materials with plasma environments. Results demonstrated that plasma gas, specifically helium plasma, is a highly effective sterilant and is compatible with spacecraft materials.

  12. Determination of trace amounts of chemical warfare agent degradation products in decontamination solutions with NMR spectroscopy.

    PubMed

    Koskela, Harri; Rapinoja, Marja-Leena; Kuitunen, Marja-Leena; Vanninen, Paula

    2007-12-01

    Decontamination solutions are used for an efficient detoxification of chemical warfare agents (CWAs). As these solutions can be composed of strong alkaline chemicals with hydrolyzing and oxidizing properties, the analysis of CWA degradation products in trace levels from these solutions imposes a challenge for any analytical technique. Here, we present results of application of nuclear magnetic resonance spectroscopy for analysis of trace amounts of CWA degradation products in several untreated decontamination solutions. Degradation products of the nerve agents sarin, soman, and VX were selectively monitored with substantially reduced interference of background signals by 1D 1H-31P heteronuclear single quantum coherence (HSQC) spectrometry. The detection limit of the chemicals was at the low part-per-million level (2-10 microg/mL) in all studied solutions. In addition, the concentration of the degradation products was obtained with sufficient confidence with external standards.

  13. Experimental Investigation of the Plasma Bullet and Its Applications

    DTIC Science & Technology

    2012-08-01

    W. Hynes, M. Laroussi, and S. L. Tolle, “Cold Plasma Technology: Bactericidal Effects on Geobacillus Stearothermophilus and Bacillus Cereus...Polymers on Plasma Sterilization and Decontamination (Vol. 9, No. 6, 2012). The PI was a member of the Scientific Organizing Committee of two major

  14. DECONTAMINATION WIPES FOR FIRST RESPONDERS - PHASE I

    EPA Science Inventory

    The threat of chemical or biological (CB) attack is real, and there is a recognized need for improved technologies to better respond to these situations. During a CB emergency, first responder units are critical for handling the emergency, and then restoring the environment wh...

  15. CO{sub 2} pellet decontamination technology at Westinghouse Hanford

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aldridge, T.L.; Aldrich, L.K. II; Bowman, E.V.

    1995-03-01

    Experimentation and testing with CO{sub 2} pellet decontamination technology is being conducted at Westinghosue Hanford Company (WHC), Richland, Washington. There are 1,100 known existing waste sites at Hanford. The sites specified by federal and state agencies are currently being studied to determine the appropriate cleanup methods best for each site. These sites are contaminated and work on them is in compliance with the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA). There are also 63 treatment, storage, and disposal units, for example: groups of waste tanks or drums. In 1992, there were 100 planned activities scheduled to bring these unitsmore » into the Resource Conservation and Recovery Act (RCRA) compliance or close them after waste removal. Ninety-six of these were completed. The remaining four were delayed or are being negotiated with regulatory agencies. As a result of past defense program activities at Hanford a tremendous volume of materials and equipment have accumulated and require remediation.« less

  16. A Year in the Life of a Contaminated Heater-Cooler Unit With Mycobacterium chimaera?

    PubMed

    Garvey, Mark I; Bradley, Craig W; Walker, Jimmy

    2017-06-01

    OBJECTIVE Heater-cooler units (HCUs) have been shown to be a source of Mycobacterium chimaera infections. For the past year, weekly water samples have been taken from HCUs used at University Hospitals Birmingham (UHB) NHS Foundation Trust. We report the microbial contamination of the HCUs over a year detailing the decontamination regimes applied at UHB to reduce the microbial load. DESIGN Observational study SETTING UHB is a tertiary referral teaching hospital in Birmingham, United Kingdom, that provides clinical services to nearly 1 million patients every year. The UHB Cardiac department is one of the largest in the United Kingdom and provides treatment for adult patients with a wide range of cardiac diseases. METHODS Water samples taken from HCUs used at UHB for cardiopulmonary bypass surgery were sampled over a year to determine the number of microorganisms by membrane filtration. Various decontamination processes were employed throughout the year. RESULTS Varying total viable counts containing a wide variety of microorganisms were obtained from water inside the HCUs. No M. chimaera were isolated after replacement of the HCU internal tubing. Stringent decontamination regimes resulted in degradation of the HCUs and increased TVCs after several months. CONCLUSION More work is required to ensure effective decontamination processes to reduce the microbial load within the HCUs. Our studies indicate that weekly water sampling for TVC will be required indefinitely to monitor the water quality in these units as well as regular replacement of the tubing to control the build-up of biofilm. Infect Control Hosp Epidemiol 2017;38:705-711.

  17. Safety of dermal diphoterine application: an active decontamination solution for chemical splash injuries.

    PubMed

    Hall, Alan H; Cavallini, Maurizio; Mathieu, Laurence; Maibach, Howard I

    2009-01-01

    Diphoterine (Laboratoire Prevor, Valmondois, France) is an active, amphoteric, polyvalent, chelating, slightly hypertonic decontamination solution for chemical splashes to the skin and eyes. It chemically binds a large number of chemical substances present on the skin surface without causing a significant release of heat (exothermic reactions). Because of its amphoteric properties, it can bind chemically opposite substances such as acids and bases or oxidizers and reducing agents. No adverse effects have been observed in an ongoing postmarketing surveillance program during many years of use in European industrial facilities. Diphoterine has more recently been used in hospitals for delayed management of chemical burns to the skin and eyes. There is interest in having protocols for both immediate and delayed diphoterine use for skin decontamination. Whereas studies of diphoterine efficacy, clinical and in vitro or ex vivo, have been published or are in the process of being prepared for publication, no review has yet been published focusing solely on the safety of this decontamination solution. Therefore, all available studies on the safety of diphoterine are described here, including recent studies demonstrating no harmful effects on the skin. Diphoterine can be used, even on damaged skin, without toxic, irritant, allergenic, or sensitizing effects.

  18. Treatment of Acute Periodontal Abscesses Using the Biofilm Decontamination Approach: A Case Report Study.

    PubMed

    Pini-Prato, Giovanpaolo; Magnani, Cristina; Rotundo, Roberto

    2016-01-01

    The aim of this preliminary study was to show the treatment effect of the biofilm decontamination approach on acute periodontal abscesses. Clinical cases showing acute periodontitis were treated using an oral tissue decontaminant material that contains a concentrated aqueous mixture of hydroxybenzenesulfonic and hydroxymethoxybenzene acids and sulfuric acid. The material was positioned into the pocket on the root surface and left in the site for 30 seconds. No instrumentation was performed before the treatment. No systemic or local antibiotics were used in any of the cases. A questionnaire was used for each patient to record the pain/discomfort felt when the material was administered. All of the treated cases healed well and very rapidly. The infections were quickly resolved without complications, and the pockets associated with marginal tissue recession were also reduced. The momentary pain upon introduction of the material was generally well tolerated in the nonsurgically treated cases, and it completely disappeared after a few seconds. The biofilm decontamination approach seems to be a very promising technique for the treatment of acute periodontal abscess. The local application of this material avoids the use of systemic or local antibiotics.

  19. Pathogen-reduced platelets for the prevention of bleeding

    PubMed Central

    Estcourt, Lise J; Malouf, Reem; Hopewell, Sally; Trivella, Marialena; Doree, Carolyn; Stanworth, Simon J; Murphy, Michael F

    2017-01-01

    Background Platelet transfusions are used to prevent and treat bleeding in people who are thrombocytopenic. Despite improvements in donor screening and laboratory testing, a small risk of viral, bacterial, or protozoal contamination of platelets remains. There is also an ongoing risk from newly emerging blood transfusion-transmitted infections for which laboratory tests may not be available at the time of initial outbreak. One solution to reduce the risk of blood transfusion-transmitted infections from platelet transfusion is photochemical pathogen reduction, in which pathogens are either inactivated or significantly depleted in number, thereby reducing the chance of transmission. This process might offer additional benefits, including platelet shelf-life extension, and negate the requirement for gamma-irradiation of platelets. Although current pathogen-reduction technologies have been proven to reduce pathogen load in platelet concentrates, a number of published clinical studies have raised concerns about the effectiveness of pathogen-reduced platelets for post-transfusion platelet count recovery and the prevention of bleeding when compared with standard platelets. This is an update of a Cochrane review first published in 2013. Objectives To assess the effectiveness of pathogen-reduced platelets for the prevention of bleeding in people of any age requiring platelet transfusions. Search methods We searched for randomised controlled trials (RCTs) in the Cochrane Central Register of Controlled Trials (CENTRAL) (the Cochrane Library 2016, Issue 9), MEDLINE (from 1946), Embase (from 1974), CINAHL (from 1937), the Transfusion Evidence Library (from 1950), and ongoing trial databases to 24 October 2016. Selection criteria We included RCTs comparing the transfusion of pathogen-reduced platelets with standard platelets, or comparing different types of pathogen-reduced platelets. Data collection and analysis We used the standard methodological procedures expected by Cochrane. Main results We identified five new trials in this update of the review. A total of 15 trials were eligible for inclusion in this review, 12 completed trials (2075 participants) and three ongoing trials. Ten of the 12 completed trials were included in the original review. We did not identify any RCTs comparing the transfusion of one type of pathogen-reduced platelets with another. Nine trials compared Intercept® pathogen-reduced platelets to standard platelets, two trials compared Mirasol® pathogen-reduced platelets to standard platelets; and one trial compared both pathogen-reduced platelets types to standard platelets. Three RCTs were randomised cross-over trials, and nine were parallel-group trials. Of the 2075 participants enrolled in the trials, 1981 participants received at least one platelet transfusion (1662 participants in Intercept® platelet trials and 319 in Mirasol® platelet trials). One trial included children requiring cardiac surgery (16 participants) or adults requiring a liver transplant (28 participants). All of the other participants were thrombocytopenic individuals who had a haematological or oncological diagnosis. Eight trials included only adults. Four of the included studies were at low risk of bias in every domain, while the remaining eight included studies had some threats to validity. Overall, the quality of the evidence was low to high across different outcomes according to GRADE methodology. We are very uncertain as to whether pathogen-reduced platelets increase the risk of any bleeding (World Health Organization (WHO) Grade 1 to 4) (5 trials, 1085 participants; fixed-effect risk ratio (RR) 1.09, 95% confidence interval (CI) 1.02 to 1.15; I2 = 59%, random-effect RR 1.14, 95% CI 0.93 to 1.38; I2 = 59%; low-quality evidence). There was no evidence of a difference between pathogen-reduced platelets and standard platelets in the incidence of clinically significant bleeding complications (WHO Grade 2 or higher) (5 trials, 1392 participants; RR 1.10, 95% CI 0.97 to 1.25; I2 = 0%; moderate-quality evidence), and there is probably no difference in the risk of developing severe bleeding (WHO Grade 3 or higher) (6 trials, 1495 participants; RR 1.24, 95% CI 0.76 to 2.02; I2 = 32%; moderate-quality evidence). There is probably no difference between pathogen-reduced platelets and standard platelets in the incidence of all-cause mortality at 4 to 12 weeks (6 trials, 1509 participants; RR 0.81, 95% CI 0.50 to 1.29; I2 = 26%; moderate-quality evidence). There is probably no difference between pathogen-reduced platelets and standard platelets in the incidence of serious adverse events (7 trials, 1340 participants; RR 1.09, 95% CI 0.88 to 1.35; I2 = 0%; moderate-quality evidence). However, no bacterial transfusion-transmitted infections occurred in the six trials that reported this outcome. Participants who received pathogen-reduced platelet transfusions had an increased risk of developing platelet refractoriness (7 trials, 1525 participants; RR 2.94, 95% CI 2.08 to 4.16; I2 = 0%; high-quality evidence), though the definition of platelet refractoriness differed between trials. Participants who received pathogen-reduced platelet transfusions required more platelet transfusions (6 trials, 1509 participants; mean difference (MD) 1.23, 95% CI 0.86 to 1.61; I2 = 27%; high-quality evidence), and there was probably a shorter time interval between transfusions (6 trials, 1489 participants; MD -0.42, 95% CI -0.53 to -0.32; I2 = 29%; moderate-quality evidence). Participants who received pathogen-reduced platelet transfusions had a lower 24-hour corrected-count increment (7 trials, 1681 participants; MD -3.02, 95% CI -3.57 to -2.48; I2 = 15%; high-quality evidence). None of the studies reported quality of life. We did not evaluate any economic outcomes. There was evidence of subgroup differences in multiple transfusion trials between the two pathogen-reduced platelet technologies assessed in this review (Intercept® and Mirasol®) for all-cause mortality and the interval between platelet transfusions (favouring Intercept®). Authors' conclusions Findings from this review were based on 12 trials, and of the 1981 participants who received a platelet transfusion only 44 did not have a haematological or oncological diagnosis. In people with haematological or oncological disorders who are thrombocytopenic due to their disease or its treatment, we found high-quality evidence that pathogen-reduced platelet transfusions increase the risk of platelet refractoriness and the platelet transfusion requirement. We found moderate-quality evidence that pathogen-reduced platelet transfusions do not affect all-cause mortality, the risk of clinically significant or severe bleeding, or the risk of a serious adverse event. There was insufficient evidence for people with other diagnoses. All three ongoing trials are in adults (planned recruitment 1375 participants) with a haematological or oncological diagnosis. PMID:28756627

  20. Prevention of infections in an ART laboratory: a reflection on simplistic methods.

    PubMed

    Huyser, C

    2014-01-01

    Preventative measures combined with reactive remedial actions are generic management tools to optimize and protect an entity's core businesses. Differences between assisted reproduction technology (ART) laboratories in developing versus developed countries include restricted access to, or availability of resources, and the prevalence of pathological conditions that are endemic or common in non-industrialized regions. The aim of this paper is to discuss the prevention of infections in an ART laboratory in a low to middle-income country, with reference to simplistic risk reduction applications to avoid the introduction and transmission of pathogens. Diagnostic and procedural phases will be examined, i.e. (i) screening for microbes during patient evaluation, and (ii-iii) prevention of environmental and procedural contamination. Preventative action is enabled by knowledge of threats and the degree of risk involved. Awareness and understanding of the vulnerabilities in an ART system, wherein laboratory personnel operate, are invaluable assets when unforeseen equipment failure occurs or instant decisions have to be made to safeguard procedures. An inter-connective team approach to patient treatment, biosafety training and utilization of practical procedures such as semen decontamination, are fundamental tools in a laboratory's risk-reduction armoury to prevent and eliminate infectious elements.

  1. Evaluation of detection methods for screening meat and poultry products for the presence of foodborne pathogens.

    PubMed

    Bohaychuk, Valerie M; Gensler, Gary E; King, Robin K; Wu, John T; McMullen, Lynn M

    2005-12-01

    Rapid and molecular technologies such as enzyme-linked immunosorbent assay (ELISA), PCR, and lateral flow immunoprecipitation can reduce the time and labor involved in screening food products for the presence of pathogens. These technologies were compared with conventional culture methodology for the detection of Salmonella, Campylobacter, Listeria, and Escherichia coli O157:H7 inoculated in raw and processed meat and poultry products. Recommended protocols were modified so that the same enrichment broths used in the culture methods were also used in the ELISA, PCR, and lateral flow immunoprecipitation assays. The percent agreement between the rapid technologies and culture methods ranged from 80 to 100% depending on the pathogen detected and the method used. ELISA, PCR, and lateral flow immunoprecipitation all performed well, with no statistical difference, compared with the culture method for the detection of E. coli O157:H7. ELISA performed better for the detection of Salmonella, with sensitivity and specificity rates of 100%. PCR performed better for the detection of Campylobacter jejuni, with 100% agreement to the culture method. PCR was highly sensitive for the detection of all the foodborne pathogens tested except Listeria monocytogenes. Although the lateral flow immunoprecipitation tests were statistically different from the culture methods for Salmonella and Listeria because of false-positive results, the tests did not produce any false negatives, indicating that this method would be suitable for screening meat and poultry products for these pathogens.

  2. Efficacy of Acetic Acid against Listeria monocytogenes Attached to Poultry Skin during Refrigerated Storage

    PubMed Central

    Gonzalez-Fandos, Elena; Herrera, Barbara

    2014-01-01

    This work evaluates the effect of acetic acid dipping on the growth of L. monocytogenes on poultry legs stored at 4 °C for eight days. Fresh inoculated chicken legs were dipped into either a 1% or 2% acetic acid solution (v/v) or distilled water (control). Changes in mesophiles, psychrotrophs, Enterobacteriaceae counts and sensorial characteristics (odor, color, texture and overall appearance) were also evaluated. The shelf life of the samples washed with acetic acid was extended by at least two days over the control samples washed with distilled water. L. monocytogenes counts before decontamination were 5.57 log UFC/g, and after treatment with 2% acetic acid (Day 0), L. monocytogenes counts were 4.47 log UFC/g. Legs washed with 2% acetic acid showed a significant (p < 0.05) inhibitory effect on L. monocytogenes compared to control legs, with a decrease of about 1.31 log units after eight days of storage. Sensory quality was not adversely affected by acetic acid. This study demonstrates that while acetic acid did reduce populations of L. monocytogenes on meat, it did not completely inactivate the pathogen. The application of acetic acid may be used as an additional hurdle contributing to extend the shelf life of raw poultry and reducing populations of L. monocytogenes. PMID:28234335

  3. Atmospheric pressure plasma jet treatment of Salmonella Enteritidis inoculated eggshells.

    PubMed

    Moritz, Maike; Wiacek, Claudia; Koethe, Martin; Braun, Peggy G

    2017-03-20

    Contamination of eggshells with Salmonella Enteritidis remains a food safety concern. In many cases human salmonellosis within the EU can be traced back to raw or undercooked eggs and egg products. Atmospheric pressure plasma is a novel decontamination method that can reduce a wide range of pathogens. The aim of this work was to evaluate the possibility of using an effective short time cold plasma treatment to inactivate Salmonella Enteritidis on the eggshell. Therefore, artificially contaminated eggshells were treated with an atmospheric pressure plasma jet under different experimental settings with various exposure times (15-300s), distances from the plasma jet nozzle to the eggshell surface (5, 8 or 12mm), feed gas compositions (Ar, Ar with 0.2, 0.5 or 1.0% O 2 ), gas flow rates (5 and 7slm) and different inoculations of Salmonella Enteritidis (10 1 -10 6 CFU/cm 2 ). Atmospheric pressure plasma could reduce Salmonella Enteritidis on eggshells significantly. Reduction factors ranged between 0.22 and 2.27 log CFU (colony-forming units). Exposure time and, particularly at 10 4 CFU/cm 2 inoculation, feed gas had a major impact on Salmonella reduction. Precisely, longer exposure times led to higher reductions and Ar as feed gas was more effective than ArO 2 mixtures. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Evaluation of peracetic acid fog for the inactivation of Bacillus anthracis spore surrogates in a large decontamination chamber.

    PubMed

    Wood, Joseph P; Calfee, Michael Worth; Clayton, Matthew; Griffin-Gatchalian, Nicole; Touati, Abderrahmane; Egler, Kim

    2013-04-15

    The purpose of this study was to evaluate the sporicidal (inactivation of bacterial spores) effectiveness and operation of a fogging device utilizing peracetic acid/hydrogen peroxide (PAA). Experiments were conducted in a pilot-scale 24 m(3) stainless steel chamber using either biological indicators (BIs) or bacterial spores deposited onto surfaces via aerosolization. Wipe sampling was used to recover aerosol-deposited spores from chamber surfaces and coupon materials before and after fogging to assess decontamination efficacy. Temperature, relative humidity, and hydrogen peroxide vapor levels were measured during testing to characterize the fog environment. The fog completely inactivated all BIs in a test using a 60 mL solution of PAA (22% hydrogen peroxide/4.5% peracetic acid). In tests using aerosol-deposited bacterial spores, the majority of the post-fogging spore levels per sample were less than 1 log colony forming units, with a number of samples having no detectable spores. In terms of decontamination efficacy, a 4.78 log reduction of viable spores was achieved on wood and stainless steel. Fogging of PAA solutions shows potential as a relatively easy to use decontamination technology in the event of contamination with Bacillus anthracis or other spore-forming infectious disease agents, although additional research is needed to enhance sporicidal efficacy. Published by Elsevier B.V.

  5. Control of Pseudomonas mastitis on a large dairy farm by using slightly acidic electrolyzed water.

    PubMed

    Kawai, Kazuhiro; Shinozuka, Yasunori; Uchida, Ikuo; Hirose, Kazuhiko; Mitamura, Takashi; Watanabe, Aiko; Kuruhara, Kana; Yuasa, Reiko; Sato, Reiichiro; Onda, Ken; Nagahata, Hajime

    2017-10-01

    The disinfection effect of slightly acidic electrolyzed water (SAEW) use in a farm where Pseudomonas mastitis has spread was evaluated. Despite the application of antibiotic therapy and complete cessation of milking infected quarters, numerous new and recurrent Pseudomonas aeruginosa clinical mastitis infections (5.8-7.1% of clinical mastitis cases) occurred on the farm from 2003 to 2005. Procedural changes and equipment modifications did not improve environmental contamination or the incidence of Pseudomonas mastitis. To more thoroughly decontaminate the milking parlor, an SAEW system was installed in 2006. All milking equipment and the parlor environment were sterilized with SAEW (pH 5-6.5, available chlorine 12 parts per million) before and during milking time. After adopting the SAEW system, the incidence of clinical and subclinical Pseudomonas mastitis cases decreased significantly (P < 0.0001) and disappeared. These findings suggest that SAEW effectively reduced the incidence of mastitis in a herd contaminated by Pseudomonas species. This is the first report to demonstrate the effectiveness of disinfection by SAEW against mastitis pathogens in the environment. © 2017 Japanese Society of Animal Science.

  6. Development of an Alternative Treatment Scheme for Sr/TRU Removal: Permanganate Treatment of AN-107 Waste

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    RT Hallen; SA Bryan; FV Hoopes

    A number of Hanford tanks received waste containing organic complexants, which increase the volubility of Sr-90 and transuranic (TRU) elements. Wastes from these tanks require additional pretreatment to remove Sr-90 and TRU for immobilization as low activity waste (Waste Envelope C). The baseline pretreatment process for Sr/TRU removal was isotopic exchange and precipitation with added strontium and iron. However, studies at both Battelle and Savannah River Technology Center (SRTC) have shown that the Sr/Fe precipitates were very difficult to filter. This was a result of the formation of poor filtering iron solids. An alternate treatment technology was needed for Sr/TRUmore » removal. Battelle had demonstrated that permanganate treatment was effective for decontaminating waste samples from Hanford Tank SY-101 and proposed that permanganate be examined as an alternative Sr/TRU removal scheme for complexant-containing tank wastes such as AW107. Battelle conducted preliminary small-scale experiments to determine the effectiveness of permanganate treatment with AN-107 waste samples that had been archived at Battelle from earlier studies. Three series of experiments were performed to evaluate conditions that provided adequate Sr/TRU decontamination using permanganate treatment. The final series included experiments with actual AN-107 diluted feed that had been obtained specifically for BNFL process testing. Conditions that provided adequate Sr/TRU decontamination were identified. A free hydroxide concentration of 0.5M provided adequate decontamination with added Sr of 0.05M and permanganate of 0.03M for archived AN-107. The best results were obtained when reagents were added in the sequence Sr followed by permanganate with the waste at ambient temperature. The reaction conditions for Sr/TRU removal will be further evaluated with a 1-L batch of archived AN-107, which will provide a large enough volume of waste to conduct crossflow filtration studies (Hallen et al. 2000a).« less

  7. Automatic environmental disinfection with hydrogen peroxide and silver ions versus manual environmental disinfection with sodium hypochlorite: a multicentre randomized before-and-after trial.

    PubMed

    Mosci, D; Marmo, G W; Sciolino, L; Zaccaro, C; Antonellini, R; Accogli, L; Lazzarotto, T; Mongardi, M; Landini, M P

    2017-10-01

    New technologies for automated disinfection have been developed, including the use of hydrogen peroxide atomized by specific equipment, with associated silver compounds. To compare the effectiveness of an automated disinfection system with hydrogen peroxide <8% and silver ion versus a manual method with 0.5% sodium hypochlorite solution when evaluating the reduction of microbial mesophilic contamination and Clostridium difficile presence; and to evaluate the time required for both of these processes. This was a randomized multicentre trial performed in different hospital wards that had been occupied previously by patients with Clostridium difficile infection. When patients were discharged their rooms were randomized to one of two decontamination arms. The surfaces where sampled using swabs, before and after disinfection. Swab samples were cultured for quantitative detection of microbial mesophilic contamination and qualitative detection of C. difficile. Before disinfection, 13% of surfaces decontaminated with hydrogen peroxide and silver ions and 20% of surfaces decontaminated with sodium hypochlorite showed presence of C. difficile spores. After disinfection, the samples containing C. difficile were 0% (P < 0.001) in the group decontaminated with hydrogen peroxide and silver ions, and were 3% (P < 0.001) in the group decontaminated with sodium hypochlorite. This difference was not statistically significant; nor was the difference in the reduction of the microbial mesophilic contamination. The differences between the groups were not statistically significant; however, the disinfection with hydrogen peroxide and silver ions is preferable due to less dependence on operators. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  8. Lasers in Esthetic Dentistry: Soft Tissue Photobiomodulation, Hard Tissue Decontamination, and Ceramics Conditioning

    PubMed Central

    Ramalho, Karen Müller; de Freitas, Patrícia Moreira; Correa-Aranha, Ana Cecília; Bello-Silva, Marina Stella; Lopes, Roberta Marques da Graça; Eduardo, Carlos de Paula

    2014-01-01

    The increasing concern and the search for conservative dental treatments have resulted in the development of several new technologies. Low and high power lasers can be cited as one of these new technologies. Low power lasers act at cellular level leading to pain reduction, modulation of inflammation, and improvement of tissue healing. High power lasers act by increasing temperature and have the potential to promote microbial reduction and ablation of hard and soft tissues. The clinical application of both low and high power lasers requires specific knowledge concerning laser interaction with biological tissues, so that the correct irradiation protocol can be established. The present case report describes the clinical steps of two metal-ceramic crowns development in a 60-year-old patient. Three different laser wavelengths were applied throughout the treatment with different purposes: Nd:YAG laser (1,064 nm) for dentin decontamination, diode (660 nm) for soft tissue biomodulation, and Er:YAG laser (2,940 nm) for inner ceramic surface conditioning. Lasers were successfully applied in the present case report as coadjutant in the treatment. This coadjutant technology can be a potential tool to assist treatment to reach the final success. PMID:25147746

  9. In situ bioremediation in Europe

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Porta, A.; Young, J.K.; Molton, P.M.

    1993-06-01

    Site remediation activity in Europe is increasing, even if not at the forced pace of the US. Although there is a better understanding of the benefits of bioremediation than of other approaches, especially about in situ bioremediation of contaminated soils, relatively few projects have been carried out full-scale in Europe or in the US. Some engineering companies and large industrial companies in Europe are investigating bioremediation and biotreatment technologies, in some cases to solve their internal waste problems. Technologies related to the application of microorganisms to the soil, release of nutrients into the soil, and enhancement of microbial decontamination aremore » being tested through various additives such as surfactants, ion exchange resins, limestone, or dolomite. New equipment has been developed for crushing and mixing or injecting and sparging the microorganisms, as have new reactor technologies (e.g., rotating aerator reactors, biometal sludge reactors, and special mobile containers for simultaneous storage, transportation, and biodegradation of contaminated soil). Some work has also been done with immobilized enzymes to support and restore enzymatic activities related to partial or total xenobiotic decontamination. Finally, some major programs funded by public and private institutions confirm that increasing numbers of firms have a working interest in bioremediation.« less

  10. Microfluidic devices for sample preparation and rapid detection of foodborne pathogens.

    PubMed

    Kant, Krishna; Shahbazi, Mohammad-Ali; Dave, Vivek Priy; Ngo, Tien Anh; Chidambara, Vinayaka Aaydha; Than, Linh Quyen; Bang, Dang Duong; Wolff, Anders

    2018-03-10

    Rapid detection of foodborne pathogens at an early stage is imperative for preventing the outbreak of foodborne diseases, known as serious threats to human health. Conventional bacterial culturing methods for foodborne pathogen detection are time consuming, laborious, and with poor pathogen diagnosis competences. This has prompted researchers to call the current status of detection approaches into question and leverage new technologies for superior pathogen sensing outcomes. Novel strategies mainly rely on incorporating all the steps from sample preparation to detection in miniaturized devices for online monitoring of pathogens with high accuracy and sensitivity in a time-saving and cost effective manner. Lab on chip is a blooming area in diagnosis, which exploits different mechanical and biological techniques to detect very low concentrations of pathogens in food samples. This is achieved through streamlining the sample handling and concentrating procedures, which will subsequently reduce human errors and enhance the accuracy of the sensing methods. Integration of sample preparation techniques into these devices can effectively minimize the impact of complex food matrix on pathogen diagnosis and improve the limit of detections. Integration of pathogen capturing bio-receptors on microfluidic devices is a crucial step, which can facilitate recognition abilities in harsh chemical and physical conditions, offering a great commercial benefit to the food-manufacturing sector. This article reviews recent advances in current state-of-the-art of sample preparation and concentration from food matrices with focus on bacterial capturing methods and sensing technologies, along with their advantages and limitations when integrated into microfluidic devices for online rapid detection of pathogens in foods and food production line. Copyright © 2018. Published by Elsevier Inc.

  11. [Decontamination of dental unit waterlines using disinfectants and filters].

    PubMed

    Monarca, S; Garusi, G; Gigola, P; Spampinato, L; Zani, C; Sapelli, P L

    2002-10-01

    Bacterial contamination of the dental unit water system can become a health problem for patients, particularly if they are immunodepressed. The present study has had the purpose of evaluating the effectiveness of methods of chemical decontamination using different disinfectants (peracetic acid, hydrogen peroxide, silver salts, chloramine T, glutaraldehyde T4) and methods of physical decontamination using synthetic membranes for the filtration of water. A preliminary removal procedure of the biofilm present in the waterline has been followed in a dental unit prepared on purpose for the research; subsequently different 2-week long maintenance procedures were applied using disinfectants injected by a pump and finally the bacterial contamination of the water flowing from the waterline was evaluated. The physical decontamination was performed using 0.22 mm membrane filters, which have been installed also in another dental unit, and the filtered water was analyzed to detect bacterial contamination. The preliminary procedure of biofilm removal succeeded obtaining germ-free water. Among the disinfectants used for the maintenance of the water quality only glutaraldehyde T4 was able to reduce the bacterial contamination under the limit suggested by the ADA. The membrane filter system was not able to purify the water, but when a disinfectant (peracetic acid) was used in the last part of the waterline good results were obtained. At present no decontamination system of dental waterline is available, and glutaraldehyde T4 seems to be the best disinfectant only if integrated with periodic biofilm removal for the maintenance of the water quality.

  12. Experimental evaluation of an automated endoscope reprocessor with in situ generation of peracetic acid for disinfection of semicritical devices.

    PubMed

    Sattar, Syed A; Kibbee, Richard J; Tetro, Jason A; Rook, Tony A

    2006-11-01

    To evaluate the effectiveness of a high-level disinfection solution generated inside an endoscope processing system for decontaminating external and internal surfaces of experimentally contaminated heat-sensitive medical devices. The American Society for Testing and Materials Simulated-Use Test protocol (E1837-02), which incorporates a soil load in each inoculum, was used to evaluate the efficacy of the system when processing 4 common types of endoscopes contaminated separately with 5 types of nosocomial pathogens: Pseudomonas aeruginosa (ATCC 15442), spores of Clostridium difficile (ATCC 9689), a glutaraldehyde-resistant strain of Mycobacterium chelonae, a vancomycin-resistant strain of Enterococcus faecalis, and a methicillin-resistant strain of Staphylococcus aureus. Rinse solution samples from channels and from surfaces of the processed endoscopes were tested for any microbicidal residues. For all organisms tested, the baseline level of contamination of the endoscopes ranged from 5 log(10) to greater than 7 log(10) at each external surface site and internal channel. All tests showed reductions in viability of the test organisms to undetectable levels. All rinse solution samples from external and internal sites of the endoscopes proved to be free of any residual microbicidal activity. The endoscope reprocessor, with its processor-generated high-level disinfection solution, successfully reduced the numbers of selected, clinically relevant pathogens to undetectable levels both in the channels and on the outside surfaces of the 4 representative endoscopes tested in this study.

  13. Novel technologies for decontamination of fresh and minimally processed fruits and vegetables

    USDA-ARS?s Scientific Manuscript database

    The complex challenges facing producers and processors of fresh produce require creative applications of conventional treatments and innovative approaches to develop entirely novel treatments. The varied nature of fresh and fresh-cut produce demands solutions that are adapted and optimized for each ...

  14. D and D: Dismantling and Release of Large Components at the GNS Premises in Duisburg on the Example of a CASTOR S1 Container - 13536

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oehmigen, Steffen; Ambos, Frank

    There are a lot of metallic large components for the transport of radioactive waste in Germany. Some of these large components like for example the Castor S1 with 82 Mg are so old, that the transport via streets is not possible because the permission is not valid anymore. The application for a new permission is economically not reasonable. Out of this reason the large components need to be decontaminated and recycled to use them again in the economic cycle. Decontamination of large components by cleaning/removing the surface for example with beam technology is a very time-consuming release procedure. Manufacturing amore » specialized machine for decontamination and creation of a new surface was the intention of this project. The objective was to save interim storage and final repository volume and costs as well as developing a process that is nationally and internationally usable. 90% of the volume/mass of waste could be released and therefore possibly re-used. (authors)« less

  15. Arsenic removal by electrocoagulation process: Recent trends and removal mechanism.

    PubMed

    Nidheesh, P V; Singh, T S Anantha

    2017-08-01

    Arsenic contamination in drinking water is a major issue in the present world. Arsenicosis is the disease caused by the regular consumption of arsenic contaminated water, even at a lesser contaminated level. The number of arsenicosis patients is increasing day-by-day. Decontamination of arsenic from the water medium is the only one way to regulate this and the arsenic removal can be fulfilled by water treatment methods based on separation techniques. Electrocoagulation (EC) process is a promising technology for the effective removal of arsenic from aqueous solution. The present review article analyzes the performance of the EC process for arsenic removal. Electrocoagulation using various sacrificial metal anodes such as aluminium, iron, magnesium, etc. is found to be very effective for arsenic decontamination. The performances of each anode are described in detail. A special focus has been made on the mechanism behind the arsenite and arsenate removal by EC process. Main trends in the disposal methods of sludge containing arsenic are also included. Comparison of arsenic decontamination efficiencies of chemical coagulation and EC is also reported. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Optimization of SHINE Process: Design and Verification of Plant-Scale AG 1 Anion-Exchange Concentration Column and Titania Sorbent Pretreatment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stepinski, Dominique C.; Abdul, Momen; Youker, Amanda J.

    2016-06-01

    Argonne National Laboratory has developed a Mo-recovery and -purification system for the SHINE medical technologies process, which uses a uranyl sulfate solution for the accelerator-driven production of Mo-99. The objective of this effort is to reduce the processing time for the acidification of the Mo-99 product prior to loading onto a concentration column and concentration of the Mo-99 product solution. Two methods were investigated: (1) the replacement of the titania concentration column by an anion-exchange column to decrease processing time and increase the radioiodine-decontamination efficiency and (2) pretreatment of the titania sorbent to improve its effectiveness for the Mo-recovery andmore » -concentration columns. Promising results are reported for both methods.« less

  17. New and developing diagnostic technologies for urinary tract infections

    PubMed Central

    Davenport, Michael; Mach, Kathleen E.; Dairiki Shortliffe, Linda M.; Banaei, Niaz; Wang, Tza-Huei; Liao, Joseph C.

    2017-01-01

    Timely and accurate identification and determination of the antimicrobial susceptibility of uropathogens is central to the management of UTIs. Urine dipsticks are fast and amenable to point-of-care testing, but do not have adequate diagnostic accuracy or provide microbiological diagnosis. Urine culture with antimicrobial susceptibility testing takes 2 3 days and requires a clinical laboratory. The common use of empirical antibiotics has contributed to the rise of multidrug-resistant organisms, reducing treatment options and increasing costs. In addition to improved antimicrobial stewardship and the development of new antimicrobials, novel diagnostics are needed for timely microbial identification and determination of antimicrobial susceptibilities. New diagnostic platforms, including nucleic acid tests and mass spectrometry, have been approved for clinical use and have improved the speed and accuracy of pathogen identification from primary cultures. Optimization for direct urine testing would reduce the time to diagnosis, yet these technologies do not provide comprehensive information on antimicrobial susceptibility. Emerging technologies including biosensors, microfluidics, and other integrated platforms could improve UTI diagnosis via direct pathogen detection from urine samples, rapid antimicrobial susceptibility testing, and point-of-care testing. Successful development and implementation of these technologies has the potential to usher in an era of precision medicine to improve patient care and public health. PMID:28248946

  18. Food irradiation—US regulatory considerations

    NASA Astrophysics Data System (ADS)

    Morehouse, Kim M.

    2002-03-01

    The use of ionizing radiation in food processing has received increased interest as a means of reducing the level of foodborne pathogens. This overview discusses the regulatory issues connected with the use of this technology in the United States. Several recent changes in the FDA's review process are discussed. These include the current policy that utilizes an expedited review process for petitions seeking approval of additives and technologies intended to reduce pathogen levels in food, and the recent USDA rule that eliminates the need for a separate rulemaking process by USDA for irradiation of meat and poultry. Recently promulgated rules and pending petitions before the FDA associated with the use of ionizing radiation for the treatment of foods are also discussed along with the current FDA labeling requirements for irradiated foods and the 1999 advanced notice of proposed rule on labeling. Another issue that is presented is the current status of the approval of packaging materials intended for food contact during irradiation treatment of foods.

  19. Highly Selective Nuclide Removal from the R-Reactor Disassembly Basin at the SRS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pickett, J. B.; Austin, W. E.; Dukes, H. H.

    This paper describes the results of a deployment of highly selective ion-exchange resin technologies for the in-situ removal of Cs-137 and Sr-90 from the Savannah River Site (SRS) R-Reactor Disassembly Basin. The deployment was supported by the DOE Office of Science and Technology's (OST, EM-50) National Engineering Technology Laboratory (NETL), as a part of an Accelerated Site Technology Deployment (ASTD) project. The Facilities Decontamination and Decommissioning (FDD) Program at the SRS conducted this deployment as a part of an overall program to deactivate three of the site's five reactor disassembly basins.

  20. Highly Selective Nuclide Removal from the R-Reactor Disassembly Basin at SRS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pickett, J.B.

    This paper describes the results of a deployment of highly selective ion-exchange resin technologies for the in-situ removal of Cs-137 and Sr-90 from the Savannah River Site (SRS) R-Reactor Disassembly Basin. The deployment was supported by the DOE Office of Science and Technology's (OST, EM-50) National Engineering Technology Laboratory (NETL), as a part of an Accelerated Site Technology Deployment (ASTD) project. The Facilities Decontamination and Decommissioning (FDD) Program at the SRS conducted this deployment as a part of an overall program to deactivate three of the site's five reactor disassembly basins

  1. Staphylococcus xylosus PCR-validated Decontamination of Murine Individually Ventilated Cage Racks and Air Handling Units by Using 'Active-Closed' Exposure to Vaporized Hydrogen Peroxide.

    PubMed

    Ragland, Natalie H; Miedel, Emily L; Gomez, Jose M; Engelman, Robert W

    2017-11-01

    Vaporized hydrogen peroxide (VHP) is used to decontaminate clinical, biocontainment, and research animal rooms and equipment. To assist with its implementation in a murine facility, we developed a safe and effective method of VHP sterilization of IVC racks and air handling units (AHU). Safety of VHP decontamination was assessed by ensuring VHP levels dissipated to less than 1 ppm in the room prior to personnel reentry and inside the primary enclosure prior to the return of mice; this condition occurred at least 18 h after the VHP cycle. Efficacy of VHP sterilization was assessed by using chemical indicators, biologic indicators, and PCR testing for Staphylococcus xylosus, a commensal organism of murine skin and an opportunistic pathogen, which was present in 160 of 172 (93%) of specimens from occupied IVC racks and the interior surfaces of in-use AHU. Neither mechanized washing nor hand-sanitizing eradicated S. xylosus from equipment airway interiors, with 17% to 24% of specimens remaining PCR-positive for S. xylosus. 'Static-open' VHP exposure of sanitized equipment did not ensure its sterilization. In contrast, 'active-closed' VHP exposure, in which IVC racks were assembled, sealed, and connected to AHU set to the VHP cycle, increased the proportion of chemical indicators that detected sterilizing levels of VHP inside the assembled equipment, and significantly decreased PCR-detectable S. xylosus inside the equipment. Supplementing bulk steam sterilization of the primary enclosure with VHP sterilization of the secondary housing equipment during room change-outs may help to mitigate opportunistic agents that jeopardize studies involving immunodeficient strains.

  2. Simultaneous drying and decontamination of rough rice using combined pulsed light and holding treatment

    USDA-ARS?s Scientific Manuscript database

    Pulsed light (PL) technology has been proven effective in food disinfection. However, increasing the light intensity or treatment time could swiftly increase the temperature of the food product. Using the thermal effect in an appropriate way may achieve a simultaneous disinfection and drying effect....

  3. SITE EMERGING TECHNOLOGY SUMMARY. BIOSCRUBBER FOR REMOVING HAZARDOUS ORGANIC EMISSIONS FROM SOIL, WATER, AND AIR DECONTAMINATION PROCESSES

    EPA Science Inventory

    An advanced biofiltration system has been developed for the removal of trace organic contaminants in air. This bioscrubber uses activated carbon as a support for biogrowth. An advanced engineering design was incorporated into the bioscrubber to allow biomass removal and nutrient ...

  4. Effect of different GRAS compounds in the control of apples blue mould.

    PubMed

    Venditti, T; Cubaiu, L; Ladu, G; D'Hallewin, G

    2013-01-01

    The most important pathogen for apples is Penicillium expansum that is the causal organism of blue mould. Postharvest losses are controlled with chemical fungicides such as TBZ but a growing concern for human health and a greater awareness for environmental conservation have multiplied the studies on new ecological technologies. In the search of new environment and consumer friendly technologies that can reduce toxic residues, the use of GRAS compounds represent a valid alternative to the use of synthetic postharvest fungicides. The aims of the present work were: (1) To evaluate the effectiveness of different GRAS compounds in the control of P. expansum in artificially inoculated fruit; (2) To assess the capability of injured and treated fruit with GRAS compounds, used alone or combined, to heal the wounds in order to resist to infection. Fruit was injured with a steel rod and after 1 hour was (1) Inoculated with the pathogen and after 24 hours treated or (2) Treated and after 24 hours inoculated. Treatments were performed with the following compounds: sodium bicarbonate (SBC), boric acid (BA) and calcium chloride (CC) by using a 1% solution for all of them. After 9 or 14 days fruit lesion diameters were assessed. In the trial (1) the combined treatment with BA and SBC was the most effective reducing the lesion diameter by 86.5% with respect to untreated fruit, after 9 days from infection. A good pathogen control was also obtained with BA used alone or combined with CC. When the treatment was performed before infection the best results were achieved with the combination of SBC and CC, with 87% of reduction of the lesion diameter. The addition of CC also reduced the lesion if combined with BA (66.8%). These preliminary results showed that GRAS compounds can be effective in reducing blue mold by a direct effect on the pathogen, and by modulating fruit responses enhancing host resistance.

  5. Showering effectiveness for human hair decontamination of the nerve agent VX.

    PubMed

    Josse, Denis; Wartelle, Julien; Cruz, Catherine

    2015-05-05

    In this work, our goals were to establish whether hair decontamination by showering one hour post-exposure to the highly toxic organophosphate nerve agent VX was effective, whether it required the addition of a detergent to water and, if it could be improved by using the adsorbent Fuller's Earth (FE) or the Reactive Skin Decontamination Lotion (RSDL) 30 min prior to showering. Hair exposure to VX and decontamination was performed by using an in vitro model. Hair showering led to 72% reduction of contamination. Addition of detergent to water slightly increased the decontamination effectiveness. Hair treatment with FE or RSDL improved the decontamination rate. Combination of FE use and showering, which yielded a decontamination factor of 41, was demonstrated to be the most effective hair decontamination procedure. Hair wiping after showering was shown to contribute to hair decontamination. Altogether, our results highlighted the importance of considering hair decontamination as an important part of body surface decontamination protocols. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  6. Alternate retrieval technology demonstrations program - test report (ARD Environmental, Inc.)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berglin, E.J.

    A prototype vehicle, control system, and waste and water scavenging system were designed and fabricated with essentially the full capabilities of the vehicle system proposed by ARD Environmental. A test tank mockup, including riser and decontamination chamber were designed and fabricated, and approximately 830 cubic feet of six varieties of waste simulants poured. The tests were performed by ARD Environmental personnel at its site in Laurel, Maryland, from 4/22/97 through 5/2/97. The capabilities tested were deployment and retrieval, extended mobility and productivity, the ability to operate the system using video viewing only, retrieval after simulated failure, and retrieval and decontamination.more » Testing commenced with deployment of the vehicle into the tank. Deployment was accomplished using a crane and auxiliary winch to position the vehicle and lower it through the decontamination chamber, into the 36`` diameter x 6` high riser, and touch down on the waste field in the tank. The initial mobility tests were conducted immediately after deployment, prior to sluicing, as the waste field exhibited the greatest amount of variation at this time. This test demonstrated the ability of the vehicle to maneuver over the simulated waste field, and the ability of the operator to work with only video viewing available. In addition, the ability of the vehicle to right itself after being turned on its side was demonstrated. The production rate was evaluated daily through the testing period by measuring the surface and estimating the amount of material removed. The test demonstrated the ability of the vehicle to reduce the waste surface using 400 psi (nominal) water jets, scavenge water and material from the work area, and move to any location, even in the relatively confined space of the 20` diameter test tank. In addition, the ability to sluice to a remote scavenging module was demonstrated. The failure mode test demonstrated the ability to retrieve a stuck vehicle by pulling on the tether, even if the vehicle wheels were locked or the vehicle was on its side. Line pull required to retrieve the vehicle was measured, and side load on the riser calculated from the line pull and line angles. Finally, the decontamination test demonstrated the ability to effectively clean the umbilical and vehicle. The issues addressed and resolved during the testing were: Feasibility of deploying a vehicle- based system, mobility, production rate and limitation of water in the tank during sluicing, mining strategy, operator efficiency, vehicle recovery, and decontamination. Water usage and waste removal rates were used to estimate the time and water usage requirements for cleaning a Hanford SST.« less

  7. Potential of Aqueous Ozone to Control Aflatoxigenic Fungi in Brazil Nuts

    PubMed Central

    Morales-Valle, Héctor; Venâncio, Armando

    2013-01-01

    This study aimed to verify the use of aqueous ozone as alternative technology for fungal control. Brazil nuts sterilized were inoculated with either 1 × 106 or 1 × 107 conidia mL−1 of Aspergillus flavus (MUM 9201) to determine optimal treatment parameters and different aqueous ozone contact times. These assays showed that the effect of ozone is almost immediate against A. flavus, and the optimum ozone concentration depended on the number of initial viable spores on the shell. The remaining viable spores in the ozone solution were recorded, and the rate of inactivation for each treatment was determined by assessing the ratio between the cfu of each treatment and the control. The ozonized nuts were also cultured to recover the fungal population. Aqueous ozone was effective in reducing the conidia of A. flavus and the natural fungal population associated with Brazil nuts. Aqueous ozone presented a great potential to reduce microorganisms counts in Brazil nuts with a great potential use in packing houses for decontamination step. PMID:25937982

  8. Inactivation of Escherichia coli O157:H7 and Listeria monocytogenes in biofilms by pulsed ultraviolet light.

    PubMed

    Montgomery, Nedra L; Banerjee, Pratik

    2015-06-10

    The inactivation of biofilms formed by pathogenic bacteria on ready-to-eat and minimally processed fruits and vegetables by nonthermal processing methods is critical to ensure food safety. Pulsed ultraviolet (PUV) light has shown promise in the surface decontamination of liquid, powdered, and solid foods. In this study, the antimicrobial efficacy of PUV light treatment on nascent biofilms formed by Escherichia coli O157:H7 and Listeria monocytogenes on the surfaces of food packaging materials, such as low-density polyethylene (LDPE), and fresh produce, such as lettuce (Lactuca sativa) leaves, was investigated. The formation of biofilms on Romaine lettuce leaves and LDPE films was confirmed by crystal violet and Alcian blue staining methods. Inactivation of cells in the biofilm was determined by standard plating procedures, and by a luminescence-based bacterial cell viability assay. Upon PUV treatment of 10 s at two different light source to sample distances (4.5 and 8.8 cm), viable cell counts of L. monocytogenes and E. coli O157:H7 in biofilms on the lettuce surface were reduced by 0.6-2.2 log CFU mL(-1) and 1.1-3.8 log CFU mL(-1), respectively. On the LDPE surface, the efficiency of inactivation of biofilm-encased cells was slightly higher. The maximum values for microbial reduction on LDPE were 2.7 log CFU mL(-1) and 3.9 log CFU mL(-1) for L. monocytogenes and E. coli O157:H7, respectively. Increasing the duration of PUV light exposure resulted in a significant (P < 0.05) reduction in biofilm formation by both organisms. The results also revealed that PUV treatment was more effective at reducing E. coli biofilms compared with Listeria biofilms. A moderate increase in temperature (~7-15°C) was observed for both test materials. PUV is an effective nonthermal intervention method for surface decontamination of E. coli O157:H7 and L. monocytogenes on fresh produce and packaging materials.

  9. Reduction of Microbial and Chemical Contaminants in Water Using POU/POE & Mobile Treatment Technologies

    EPA Science Inventory

    POU/POE may be a cost-effective option for reductions of a particular chemical to achieve water quality compliance under certain situations and given restrictions. Proactive consumers seeking to reduce exposure to potential pathogens, trace chemicals, and nanoparticles not curre...

  10. Ultrasound as an intervention technology for the sanitation of lettuce harvesting knife

    USDA-ARS?s Scientific Manuscript database

    Lettuce field-coring and trimming practices are recent industry developments designed to improve fresh-cut processing yield and reduce shipping and waste disposal costs. Studies showed that the harvesting/coring knives used could be potentially contaminated with pathogens by contact with contaminat...

  11. An evaluation of technologies for the heavy metal remediation of dredged sediments.

    PubMed

    Mulligan, C N; Yong, R N; Gibbs, B F

    2001-07-30

    Sediments dewatering is frequently necessary after dredging to remediate and treat contaminants. Methods include draining of the water in lagoons with or without coagulants and flocculants, or using presses or centrifuges. Treatment methods are similar to those used for soil and include pretreatment, physical separation, thermal processes, biological decontamination, stabilization/solidification and washing. However, compared to soil treatment, few remediation techniques have been commercially used for sediments. In this paper, a review of the methods that have been used and an evaluation of developed and developing technologies is made. Sequential extraction technique can be a useful tool for determining metal speciation before and after washing. Solidification/stabilization techniques are successful but significant monitoring is required, since the solidification process can be reversible. In addition, the presence of organics can reduce treatment efficiency. Vitrification is applicable for sediments but expensive. Only if a useful glass product can be sold will this process be economically viable. Thermal processes are only applicable for removal of volatile metals, such as mercury and costs are high. Biological processes are under development and have the potential to be low cost. Since few low cost metal treatment processes for sediments are available, there exists significant demand for further development. Pretreatment may be one of the methods that can reduce costs by reducing the volumes of sediments that need to be treated.

  12. Cleaning, disinfection and sterilization of surface prion contamination.

    PubMed

    McDonnell, G; Dehen, C; Perrin, A; Thomas, V; Igel-Egalon, A; Burke, P A; Deslys, J P; Comoy, E

    2013-12-01

    Prion contamination is a risk during device reprocessing, being difficult to remove and inactivate. Little is known of the combined effects of cleaning, disinfection and sterilization during a typical reprocessing cycle in clinical practice. To investigate the combination of cleaning, disinfection and/or sterilization on reducing the risk of surface prion contamination. In vivo test methods were used to study the impact of cleaning alone and cleaning combined with thermal disinfection and high- or low-temperature sterilization processes. A standardized test method, based on contamination of stainless steel wires with high titres of scrapie-infected brain homogenates, was used to determine infectivity reduction. Traditional chemical methods of surface decontamination against prions were confirmed to be effective, but extended steam sterilization was more variable. Steam sterilization alone reduced the risk of prion contamination under normal or extended exposure conditions, but did show significant variation. Thermal disinfection had no impact in these studies. Cleaning with certain defined formulations in combination with steam sterilization can be an effective prion decontamination process, in particular with alkaline formulations. Low-temperature, gaseous hydrogen peroxide sterilization was also confirmed to reduce infectivity in the presence and absence of cleaning. Prion decontamination is affected by the full reprocessing cycle used on contaminated surfaces. The correct use of defined cleaning, disinfection and sterilization methods as tested in this report in the scrapie infectivity assay can provide a standard precaution against prion contamination. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  13. Measurement of internal radiation exposure among decontamination workers in villages near the crippled Fukushima Daiichi Nuclear Power Plant.

    PubMed

    Tsubokura, Masaharu; Nihei, Masahiko; Sato, Katsumi; Masaki, Shin; Sakuma, Yu; Kato, Shigeaki; Sugimoto, Amina; Nomura, Shuhei; Matsumura, Tomoko; Miyazaki, Makoto; Hayano, Ryugo; Shibuya, Kenji; Kami, Masahiro; Sasaki, Taro

    2013-10-01

    Decontamination workers may face a high risk of exposure to internal irradiation through inhalation during decontamination activities; there is, however, little previous research on the levels of internal contamination during decontamination procedures. The authors reviewed the medical records, including whole body counter measurements, of decontamination workers in villages near the crippled Fukushima Daiichi Nuclear Power Plant to assess their levels of internal radiation exposure. In total, 83 decontamination workers were enrolled in this study. They were regularly engaged in decontamination activities in highly contaminated areas where surface 137Cs deposition density was over 100 kBq m-2. The present study showed low levels of internal exposure among the decontamination workers near the Fukushima Daiichi nuclear plant. The cesium burdens of all the decontamination workers were below detection limits. They had reported no acute health problems. The resuspension of radioactive materials may cause minimal internal contamination during decontamination activities.

  14. Lessons Learned from Decontamination Experiences

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sorensen, JH

    2000-11-16

    This interim report describes a DOE project currently underway to establish what is known about decontamination of buildings and people and the procedures and protocols used to determine when and how people or buildings are considered ''clean'' following decontamination. To fulfill this objective, the study systematically examined reported decontamination experiences to determine what procedures and protocols are currently employed for decontamination, the timeframe involved to initiate and complete the decontamination process, how the contaminants were identified, the problems encountered during the decontamination process, how response efforts of agencies were coordinated, and the perceived social psychological effects on people who weremore » decontaminated or who participated in the decontamination process. Findings and recommendations from the study are intended to aid decision-making and to improve the basis for determining appropriate decontamination protocols for recovery planners and policy makers for responding to chemical and biological events.« less

  15. In vitro skin decontamination of the organophosphorus pesticide Paraoxon with nanometric cerium oxide CeO2.

    PubMed

    Salerno, Alicia; Devers, Thierry; Bolzinger, Marie-Alexandrine; Pelletier, Jocelyne; Josse, Denis; Briançon, Stéphanie

    2017-04-01

    Organophosphorus compounds (OP), which mainly penetrate via the percutaneous pathway, represent a threat for both military and civilians. Body surface decontamination is vital to prevent victims poisoning. The development of a cost-effective formulation, which could be efficient and easy to handle in case of mass contamination, is therefore crucial. Metal oxides nanoparticles, due their large surface areas and the large amount of highly reactive sites, present high reactivity towards OP. First, this study aimed at evaluating the reaction of CeO 2 nanoparticles, synthetized by microwave path and calcined at 500 or 600 °C, with Paraoxon (POX) in aqueous solution. Results showed that both nanoparticles degraded 60%-70% of POX. CeO 2 calcined at 500 °C, owing to its larger specific area, was the most effective. Moreover, the degradation was significantly increased under Ultra-Violet irradiation (initial degradation rate doubled). Then, skin decontamination was studied in vitro using the Franz cell method with pig-ear skin samples. CeO 2 powder and an aqueous suspension of CeO 2 (CeO 2 -W) were applied 1 h after POX exposure. The efficiency of decontamination, including removal and/or degradation of POX, was compared to Fuller's earth (FE) and RSDL lotion which are, currently, the most efficient systems for skin decontamination. CeO 2 -W and RSDL were the most efficient to remove POX from the skin surface and decrease skin absorption by 6.4 compared to the control not decontaminated. FE reduced significantly (twice) the absorbed fraction of POX, contrarily to CeO 2 powder. Considering only the degradation rate of POX, the products ranged in the order CeO 2  > RSDL > CeO 2 -W > FE (no degradation). This study showed that CeO 2 nanoparticles are a promising material for skin decontamination of OP if formulated as a dispersion able to remove POX like CeO 2 -W and to degrade it as CeO 2 powder. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  16. Cellular Injuries in Cronobacter sakazakii CIP 103183T and Salmonella enterica Exposed to Drying and Subsequent Heat Treatment in Milk Powder.

    PubMed

    Lang, Emilie; Guyot, Stéphane; Peltier, Caroline; Alvarez-Martin, Pablo; Perrier-Cornet, Jean-Marie; Gervais, Patrick

    2018-01-01

    Because of the ability of foodborne pathogens to survive in low-moisture foods, their decontamination is an important issue in food protection. This study aimed to clarify some of the cellular mechanisms involved in inactivation of foodborne pathogens after drying and subsequent heating. Individual strains of Salmonella Typhimurium, Salmonella Senftenberg, and Cronobacter sakazakii were mixed into whole milk powder and dried to different water activity levels (0.25 and 0.58); the number of surviving cells was determined after drying and subsequent thermal treatments in closed vessels at 90 and 100°C, for 30 and 120 s. For each condition, the percentage of unculturable cells was estimated and, in parallel, membrane permeability and respiratory activity were estimated by flow cytometry using fluorescent probes. After drying, it was clearly observable that the percentage of unculturable cells was correlated with the percentage of permeabilized cells (responsible for 20-40% of the total inactivated bacteria after drying), and to a lesser degree with the percentage of cells presenting with loss of respiratory activity. In contrast, the percentages of unculturable cells observed after heat treatment were strongly correlated with the loss of respiratory activity and weakly with membrane permeability (for 70-80% of the total inactivated bacteria after heat treatment). We conclude that cell inactivation during drying is closely linked to membrane permeabilization and that heat treatment of dried cells affects principally their respiratory activity. These results legitimize the use of time-temperature scales and allow better understanding of the cellular mechanisms of bacterial death during drying and subsequent heat treatment. These results may also allow better optimization of the decontamination process to ensure food safety by targeting the most deleterious conditions for bacterial cells without denaturing the food product.

  17. Detecting anthrax in the palm of your hand: applications of a smartphone microscope

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Erikson, Rebecca L.; Hutchison, Janine R.

    Bacillus anthracis is a bacterial pathogen that causes the disease anthrax. In 2001, B. anthracis was used in a bioterrorism attack in the United States that resulted in 22 individuals becoming infected, 5 of whom died as a result of this attack. A great deal of attention has been dedicated to responding to bioterrorism events to reduce the potential loss of lives. One such area of research has focused on the development of new technologies to detect and respond to the intentional release of bacterial pathogens such as B. anthracis.

  18. Clinical aspects of percutaneous poisoning by the chemical warfare agent VX: effects of application site and decontamination.

    PubMed

    Hamilton, Murray G; Hill, Ira; Conley, John; Sawyer, Thomas W; Caneva, Duane C; Lundy, Paul M

    2004-11-01

    O-ethyl S-(2-diisopropylaminoethyl) methylphosphonothioate (VX) is an extremely toxic organophosphate nerve agent that has been weaponized and stockpiled in a number of different countries, and it has been used in recent terrorist events. It differs from other well-known organophosphate nerve agents in that its primary use is as a contact poison rather than as an inhalation hazard. For this reason, we examined the effects of application site and skin decontamination on VX toxicity in anesthetized domestic swine after topical application. VX applied to the surface of the ear rapidly resulted in signs of toxicity consistent with the development of cholinergic crisis, including apnea and death. VX on the epigastrium resulted in a marked delayed development of toxic signs, reduced toxicity, and reduction in the rate of cholinesterase depression compared with animals exposed on the ear. Skin decontamination (15 minutes post-VX on the ear) arrested the development of clinical signs and prevented further cholinesterase inhibition and death. These results confirm earlier work that demonstrates the importance of exposure site on the resultant toxicity of this agent and they also show that decontamination postexposure has the potential to be an integral and extremely important component of medical countermeasures against this agent.

  19. Pickering emulsions for skin decontamination.

    PubMed

    Salerno, Alicia; Bolzinger, Marie-Alexandrine; Rolland, Pauline; Chevalier, Yves; Josse, Denis; Briançon, Stéphanie

    2016-08-01

    This study aimed at developing innovative systems for skin decontamination. Pickering emulsions, i.e. solid-stabilized emulsions, containing silica (S-PE) or Fuller's earth (FE-PE) were formulated. Their efficiency for skin decontamination was evaluated, in vitro, 45min after an exposure to VX, one of the most highly toxic chemical warfare agents. Pickering emulsions were compared to FE (FE-W) and silica (S-W) aqueous suspensions. PE containing an oil with a similar hydrophobicity to VX should promote its extraction. All the formulations reduced significantly the amount of VX quantified on and into the skin compared to the control. Wiping the skin surface with a pad already allowed removing more than half of VX. FE-W was the less efficient (85% of VX removed). The other formulations (FE-PE, S-PE and S-W) resulted in more than 90% of the quantity of VX removed. The charge of particles was the most influential factor. The low pH of formulations containing silica favored electrostatic interactions of VX with particles explaining the better elimination from the skin surface. Formulations containing FE had basic pH, and weak interactions with VX did not improve the skin decontamination. However, these low interactions between VX and FE promote the transfer of VX into the oil droplets in the FE-PE. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Skin decontamination of mustards and organophosphates: comparative efficiency of RSDL and Fuller's earth in domestic swine.

    PubMed

    Taysse, L; Daulon, S; Delamanche, S; Bellier, B; Breton, P

    2007-02-01

    Research in skin decontamination and therapy of chemical warfare agents has been a difficult problem due to the simultaneous requirement of rapid action and non-aggressive behaviour. The aim of this study was to compare the performance of two decontaminating systems: the Canadian Reactive Skin Decontaminant Lotion (RSDL) and the Fuller's Earth (FE). The experiment was conducted with domestic swine, as a good model for extrapolation to human skin. RSDL and FE were tested against sulphur mustard (SM), a powerful vesicant, and VX, a potent and persistent cholinesterase inhibitor. When used 5 min after contamination, the results clearly showed that both systems were active against SM (10.1 mg/cm(2)) and VX (0.06 mg/cm(2)). The potency of the RSDL/sponge was statistically better than FE against skin injury induced by SM, observed 3 days post-exposure. RSDL was rather more efficient than FE in reducing the formation of perinuclear vacuoles and inflammation processes in the epidermis and dermis. Against a severe inhibition (67%) of plasmatic cholinesterases induced by VX poisoning, the potencies of the RSDL/sponge and FE were similar. Both systems completely prevented cholinesterase inhibition, which indirectly indicates a prevention of toxic absorption through the skin.

  1. Progress on Footprint Reduction at the Hanford Site - 12406

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McKenney, Dale E.; Seeley, Paul; Farabee, Al

    2012-07-01

    The Department of Energy (DOE) Office of Environmental Management (EM) continues to reduce the footprint of legacy sites throughout the EM complex. Footprint reduction is being accomplished by focusing cleanup activities on decontamination and demolition of excess contaminated facilities, soil and groundwater remediation, and solid waste disposition. All of these initiatives are being accomplished with established technologies in proven regulatory frameworks. Ultimately, completion of these environmental cleanup activities will reduce the monitoring and maintenance costs associated with managing large federal facilities, allowing EM to place more focus on other high priority cleanup efforts and facilitate a successful transition to land-termmore » stewardship of these sites. Through the American Recovery and Reinvestment Act (ARRA) investment, the Department's cleanup footprint has been reduced by 45 percent to date, from 2411 km{sup 2} (931 mi{sup 2}) to 1336 km{sup 2} (516 mi{sup 2}s). With this significant progress on footprint reduction, the Department is on track towards their goal to reduce its overall footprint by approximately 90 percent by 2015. In addition, some areas cleaned up may become available for alternate uses (i.e. recreation, conservation, preservation, industrialization or development). Much of the work to reduce the complex's footprint occurred at the Savannah River Site in South Carolina and the Hanford Site in Washington, but cleanup continues across the complex. Footprint reduction is progressing well at the Hanford Site, supported predominantly through ARRA investment. To date, 994 km{sup 2} (384 mi{sup 2}) (65%) of footprint reduction have been achieved at Hanford, with a goal to achieve a 90% reduction by Fiscal Year 2015. The DOE EM and DOE Richland Operations Office, continue to make great progress to reduce the legacy footprint of the Hanford Site. Footprint reduction is being accomplished by focusing cleanup activities on decontamination and demolition of excess facilities, both contaminated and uncontaminated, waste site cleanup activities, and debris pile removal. All of these activities can be accomplished with proven technologies and within established regulatory frameworks. Footprint reduction goals for Fiscal Year 2011 were exceeded, largely with the help of ARRA funding. As cleanup projects are completed and the total area requiring cleanup shrinks, overall costs for surveillance and maintenance operations and infrastructure services decrease. This work completion and decrease in funding requirements to maintain waste sites and antiquated facilities allows more focus on high priority site missions (i.e. groundwater remediation, tank waste disposition, etc.) and moves Site areas closer to transition from EM to the Legacy Management program. The progress in the Hanford footprint reduction effort will help achieve success in these other important mission areas. (authors)« less

  2. Decontamination and decommissioning of the Mayaguez (Puerto Rico) facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jackson, P.K.; Freemerman, R.L.

    1989-11-01

    On February 6, 1987 the US Department of Energy (DOE) awarded the final phase of the decontamination and decommissioning of the nuclear and reactor facilities at the Center for Energy and Environmental Research (CEER), in Mayaguez, Puerto Rico. Bechtel National, Inc., was made the decontamination and decommissioning (D and D) contractor. The goal of the project was to enable DOE to proceed with release of the CEER facility for use by the University of Puerto Rico, who was the operator. This presentation describes that project and lesson learned during its progress. The CEER facility was established in 1957 as themore » Puerto Rico Nuclear Center, a part of the Atoms for Peace Program. It was a nuclear training and research institution with emphasis on the needs of Latin America. It originally consisted of a 1-megawatt Materials Testing Reactor (MTR), support facilities and research laboratories. After eleven years of operation the MTR was shutdown and defueled. A 2-megawatt TRIGA reactor was installed in 1972 and operated until 1976, when it woo was shutdown. Other radioactive facilities at the center included a 10-watt homogeneous L-77 training reactor, a natural uranium graphite-moderated subcritical assembly, a 200KV particle accelerator, and a 15,000 Ci Co-60 irradiation facility. Support facilities included radiochemistry laboratories, counting rooms and two hot cells. As the emphasis shifted to non-nuclear energy technology a name change resulted in the CEER designation, and plans were started for the decontamination and decommissioning effort.« less

  3. Transplantation of human fetal tissue for neurodegenerative diseases: validation of a new protocol for microbiological analysis and bacterial decontamination.

    PubMed

    Piroth, Tobias; Pauly, Marie-Christin; Schneider, Christian; Wittmer, Annette; Möllers, Sven; Döbrössy, Máté; Winkler, Christian; Nikkhah, Guido

    2014-01-01

    Restorative cell therapy concepts in neurodegenerative diseases are aimed at replacing lost neurons. Despite advances in research on pluripotent stem cells, fetal tissue from routine elective abortions is still regarded as the only safe cell source. Progenitor cells isolated from distinct first-trimester fetal CNS regions have already been used in clinical trials and will be used again in a new multicenter trial funded by the European Union (TRANSEURO). Bacterial contamination of human fetal tissue poses a potential risk of causing infections in the brain of the recipient. Thus, effective methods of microbial decontamination and validation of these methods are required prior to approval of a neurorestorative cell therapy trial. We have developed a protocol consisting of subsequent washing steps at different stages of tissue processing. Efficacy of microbial decontamination was assessed on rat embryonic tissue incubated with high concentrations of defined microbe solutions including representative bacterial and fungal species. Experimental microbial contamination was reduced by several log ranks. Subsequently, we have analyzed the spectrum of microbial contamination and the effect of subsequent washing steps on aborted human fetal tissue; 47.7% of the samples taken during human fetal tissue processing were positive for a microbial contamination, but after washing, no sample exhibited bacterial growth. Our data suggest that human fetal tissue for neural repair can carry microbes of various species, highlighting the need for decontamination procedures. The decontamination protocol described in this report has been shown to be effective as no microbes could be detected at the end of the procedure.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vogt

    This report describes a U.S. Department of Energy, (DOE) Chemical and Biological National Security Program project that sought to establish what is known about decontamination of structures, objects, and people following an exposure to chemical or biological materials. Specifically we sought to identify the procedures and protocols used to determine when and how people or buildings are considered ''clean'' following decontamination. To fulfill this objective, the study systematically examined reported decontamination experiences to determine what procedures and protocols are currently employed for decontamination, the timeframe involved to initiate and complete the decontamination process, how the contaminants were identified, the factorsmore » determining when people were (or were not) decontaminated, the problems encountered during the decontamination process, how response efforts of agencies were coordinated, and the perceived social psychological effects on people who were decontaminated or who participated in the decontamination process. Findings and recommendations from the study are intended to aid decision-making and to improve the basis for determining appropriate decontamination protocols for recovery planners and policy makers for responding to chemical and biological events.« less

  5. Mass Casualty Decontamination in the United States: An Online Survey of Current Practice

    PubMed Central

    Power, Sarah; Symons, Charles; Carter, Holly; Jones, Emma; Larner, Joanne; Matar, Hazem; Chilcott, Robert P.

    2016-01-01

    Mass casualty decontamination is a public health intervention that would be employed by emergency responders following a chemical, biological, or radiological incident. The decontamination of large numbers of casualties is currently most often performed with water to remove contaminants from the skin surface. An online survey was conducted to explore US fire departments' decontamination practices and their preparedness for responding to incidents involving mass casualty decontamination. Survey respondents were asked to provide details of various aspects of their decontamination procedures, including expected response times to reach casualties, disrobing procedures, approaches to decontamination, characteristics of the decontamination showering process, provision for special populations, and any actions taken following decontamination. The aim of the survey was to identify any differences in the way in which decontamination guidance is implemented across US states. Results revealed that, in line with current guidance, many US fire departments routinely use the “ladder-pipe system” for conducting rapid, gross decontamination of casualties. The survey revealed significant variability in ladder-pipe construction, such as the position and number of fire hoses used. There was also variability in decontamination characteristics, such as water temperature and water pressure, detergent use, and shower duration. The results presented here provide important insights into the ways in which implementation of decontamination guidance can vary between US states. These inconsistencies are thought to reflect established perceived best practices and local adaptation of response plans to address practical and logistical constraints. These outcomes highlight the need for evidence-based national guidelines for conducting mass casualty decontamination. PMID:27442794

  6. Microbial Quality, Safety, and Pathogen Detection by Using Quantitative PCR of Raw Salad Vegetables Sold in Dhanbad City, India.

    PubMed

    Mritunjay, Sujeet K; Kumar, Vipin

    2017-01-01

    Consumption of ready-to-eat fresh vegetables has increased worldwide, with a consequent increase in outbreaks caused by foodborne pathogens. In the Indian subcontinent, raw fresh vegetables are usually consumed without washing or other decontamination procedures, thereby leading to new food safety threats. In this study, the microbiological quality and pathogenic profile of raw salad vegetables was evaluated through standard protocols. In total, 480 samples (60 each of eight different salad vegetables) of cucumber, tomato, carrot, coriander, cabbage, beetroot, radish, and spinach were collected from different locations in Dhanbad, a city famous for its coal fields and often called the "Coal Capital of India." The samples were analyzed for total plate count, total coliforms, Escherichia coli , E. coli O157:H7, Listeria monocytogenes , and Salmonella spp. Incidences of pathogens were detected through quantitative PCR subsequent to isolation. Results showed that 46.7% (for total plate counts) and 30% (for total coliforms) of samples were unacceptable for consumption per the Food Safety and Standards Authority of India. Pathogenic microorganisms were detected in 3.7% of total samples. E. coli O157:H7 was detected in three samples of spinach (2) and beetroot ( 1 ); L. monocytogenes was detected in 14 samples of spinach ( 8 ), tomato ( 3 ), cucumber ( 2 ), and radish ( 1 ); and Salmonella spp. were detected in 16 samples of spinach ( 7 ), tomato ( 3 ), beetroot ( 2 ), cucumber ( 2 ), carrot ( 1 ), and radish ( 1 ). Pathogens were not detected in any of the cabbage and coriander samples.

  7. Pathogenesis and prevention of early pancreatic infection in experimental acute necrotizing pancreatitis.

    PubMed Central

    Foitzik, T; Fernández-del Castillo, C; Ferraro, M J; Mithöfer, K; Rattner, D W; Warshaw, A L

    1995-01-01

    OBJECTIVE: The authors test antibiotic strategies aimed at either mitigating bacterial translocation from the gut or delivering antibiotics specifically concentrated by the pancreas for prevention of early secondary infection after acute necrotizing pancreatitis. BACKGROUND: Infection currently is the principal cause of death after severe pancreatitis. The authors have shown that the risk of bacterial infection correlates directly with the degree of tissue injury in a rodent model of pancreatitis. Bacteria most likely arrive by translocation from the colon. METHODS: Severe acute necrotizing pancreatitis was induced in rats by a combination of low-dose controlled intraductal infusion of glycodeoxycholic acid superimposed on intravenous cerulein hyperstimulation. At 6 hours, animals were randomly allocated to five treatment groups: controls, selective gut decontamination (oral antibiotics and cefotaxime), oral antibiotics alone, cefotaxime alone, or imipenem. At 96 hours, surviving animals were killed for quantitative bacterial study of the cecum, pancreas, and kidney. RESULTS: The 96-hour mortality (35%) was unaffected by any treatment regimen. Cecal gram-negative bacteria were significantly reduced only by the oral antibiotics. Pancreatic infection was significantly reduced by full-gut decontamination and by imipenem, but not by oral antibiotics or by cefotaxime alone. Renal infection was reduced by both intravenous antibiotics. CONCLUSIONS: Early pancreatic infection after acute necrotizing pancreatitis can be reduced with a full-gut decontamination regimen or with an antibiotic concentrated by the pancreas (imipenem) but not by unconcentrated antibiotics of similar spectrum (cefotaxime) or by oral antibiotics alone. These findings suggest that 1) both direct bacterial translocation from the gut and hematogenous seeding interplay in pancreatic infection while hematogenous seeding is dominant at extrapancreatic sites and 2) imipenem may be useful in clinical pancreatitis. PMID:7639584

  8. Removal of Group B Streptococci Colonizing the Vagina and Oropharynx of Mice with a Bacteriophage Lytic Enzyme

    PubMed Central

    Cheng, Qi; Nelson, Daniel; Zhu, Shiwei; Fischetti, Vincent A.

    2005-01-01

    Group B streptococci (GBS) are the leading cause of neonatal meningitis and sepsis worldwide. The current treatment strategy is limited to intrapartum antibiotic prophylaxis in pregnant women to prevent early-onset neonatal diseases, but considering the potential for antibiotic resistance, the risk of losing control over the disease is high. To approach this problem, we have developed a bacteriophage (phage) lytic enzyme to remove colonizing GBS. Bacteriophage muralytic enzymes, termed lysins, are highly evolved molecules designed to degrade the cell wall of host bacteria to release phage particles from the bacterial cytoplasm. Several different lysins have been developed to specifically kill bacterial pathogens both on mucosal surfaces and in blood and represent a novel approach to control infection. A lysin cloned from a phage infecting GBS was found to contain two putative catalytic domains and one putative binding domain, which is similar to the domain organization of some staphylococcal phage lysins. The lysin (named PlyGBS) was recombinantly expressed in Escherichia coli, and purified PlyGBS efficiently killed all tested GBS serotypes in vitro. In a mouse model, a single dose of PlyGBS significantly reduced bacterial colonization in both the vagina and oropharynx. As an alternative strategy for intrapartum antibiotic prophylaxis, this approach may be used to reduce vaginal GBS colonization in pregnant women before delivery or to decontaminate newborns, thus reducing the incidence of GBS-associated neonatal meningitis and sepsis. PMID:15616283

  9. Processing loaner instruments in an ambulatory surgery center.

    PubMed

    Huter-Kunish, Gloria G

    2009-05-01

    Loaner instruments often do not arrive at receiving facilities in the time frame or the condition that is needed to use them safely. Their cleaning and decontamination status may be unknown. There may be no inventory of what has been loaned or information about processing requirements for the instrument's use. These situations can create problems for both the loaning facility and the receiving facility and must be addressed to reduce costs from damage to or loss of instruments.The use of documents and checklists to verify the cleaning,decontamination, and sterilization processes used allows ambulatory surgery centers to solve these problems,cut costs, and protect staff members and patients.

  10. Method of treating contaminated HEPA filter media in pulp process

    DOEpatents

    Hu, Jian S.; Argyle, Mark D.; Demmer, Ricky L.; Mondok, Emilio P.

    2003-07-29

    A method for reducing contamination of HEPA filters with radioactive and/or hazardous materials is described. The method includes pre-processing of the filter for removing loose particles. Next, the filter medium is removed from the housing, and the housing is decontaminated. Finally, the filter medium is processed as pulp for removing contaminated particles by physical and/or chemical methods, including gravity, flotation, and dissolution of the particles. The decontaminated filter medium is then disposed of as non-RCRA waste; the particles are collected, stabilized, and disposed of according to well known methods of handling such materials; and the liquid medium in which the pulp was processed is recycled.

  11. The radiation chemistry of nuclear reactor decontaminating reagents

    NASA Astrophysics Data System (ADS)

    Sellers, Robin M.

    Processes involved in the radiation chemistry of some typical nuclear reactor decontaminating reagents including complexing, reducing and oxidising agents are described. It is concluded that radiation-induced decomposition is only likely to be a problem with dilute formulations, and/or with minor additives such as corrosion inhibitors which are not protected from attack by the other constituents. Addition of a "sacrificial" compound may be necessary to overcome this. The importance of considering loss of function, rather than the decomposition rate of the starting material, is emphasised. Reagents based on low oxidation state metal ions (LOMI) can be regenerated by the radiation field in the presence of formate ion.

  12. Planetary quarantine. Space research and technology

    NASA Technical Reports Server (NTRS)

    1973-01-01

    The impact of satisfying satellite quarantine constraints on outer planet missions and spacecraft design are studied by considering the effects of planetary radiation belts, solar wind radiation, and space vacuum on microorganism survival. Post launch recontamination studies evaluate the effects of mission environments on particle distributions on spacecraft surfaces and effective cleaning and decontamination techniques.

  13. 94-1 Research and development project lead laboratory support. Status report, January 1--March 31, 1996

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dinehart, M.

    1996-09-01

    This document reports status and technical progress for Los Alamos National Laboratories 94-1 Research and Development projects. An introduction to the project structure and an executive summary are included. Projects described include Electrolytic Decontamination, Combustibles, Detox, Sand, Slag, and Crucible, Surveillance, and Core Technology.

  14. Drying and decontamination of pistachios with sequential infrared drying, tempering and hot air drying

    USDA-ARS?s Scientific Manuscript database

    The pistachio industry is in need of improved drying technology as the current hot air drying has low energy efficiency and drying rate and high labor cost and also does not produce safe products against microbial contamination. In the current study, dehulled and water- sorted pistachios with a mois...

  15. Appropriate technology for rural India - solar decontamination of water for emergency settings and small communities.

    PubMed

    Kang, Gagandeep; Roy, Sheela; Balraj, Vinohar

    2006-09-01

    A commercial solar water heating system was evaluated for its effectiveness in decontaminating drinking water with a view to use in emergency situations. A total of 18 seeding experiments carried out over 6 months with 10(5) to 10(7)Escherichia coli/ml showed that the solar heater produced 125 l of bacteriologically safe water in 4 h when the ambient temperature was above 30 degrees C, with a holding time of at least 2 h. The solar water heating system is inexpensive, easy to transport and set up and could provide safer drinking water for 50 people a day. It would be effective in the decrease and prevention of waterborne disease in emergency situations, and is appropriate for use in small communities.

  16. Development of a process for high capacity arc heater production of silicon for solar arrays

    NASA Technical Reports Server (NTRS)

    Meyer, T. N.

    1980-01-01

    A high temperature silicon production process using existing electric arc heater technology is discussed. Silicon tetrachloride and a reductant, liquid sodium, were injected into an arc heated mixture of hydrogen and argon. Under these high temperature conditions, a very rapid reaction occurred, yielding silicon and gaseous sodium chloride. Techniques for high temperature separation and collection of the molten silicon were developed. The desired degree of separation was not achieved. The electrical, control and instrumentation, cooling water, gas, SiCl4, and sodium systems are discussed. The plasma reactor, silicon collection, effluent disposal, the gas burnoff stack, and decontamination and safety are also discussed. Procedure manuals, shakedown testing, data acquisition and analysis, product characterization, disassembly and decontamination, and component evaluation are reviewed.

  17. Studies on residue-free decontaminants for chemical warfare agents.

    PubMed

    Wagner, George W

    2015-03-17

    Residue-free decontaminants based on hydrogen peroxide, which decomposes to water and oxygen in the environment, are examined as decontaminants for chemical warfare agents (CWA). For the apparent special case of CWA on concrete, H2O2 alone, without any additives, effectively decontaminates S-2-(diisopropylamino)ethyl O-ethyl methylphosphonothioate (VX), pinacolyl methylphosphorofluoridate (GD), and bis(2-choroethyl) sulfide (HD) in a process thought to involve H2O2 activation by surface-bound carbonates/bicarbonates (known H2O2 activators for CWA decontamination). A plethora of products are formed during the H2O2 decontamination of HD on concrete, and these are characterized by comparison to synthesized authentic compounds. As a potential residue-free decontaminant for surfaces other than concrete (or those lacking adsorbed carbonate/bicarbonate) H2O2 activation for CWA decontamination is feasible using residue-free NH3 and CO2 as demonstrated by reaction studies for VX, GD, and HD in homogeneous solution. Although H2O2/NH3/CO2 ("HPAC") decontaminants are active for CWA decontamination in solution, they require testing on actual surfaces of interest to assess their true efficacy for surface decontamination.

  18. Immuno capture PCR for rapid and sensitive identification of pathogenic Bacillus anthracis.

    PubMed

    Makam, Shivakiran S; Majumder, Saugata; Kingston, Joseph J; Urs, Radhika M; Tuteja, Urmil; Sripathi, Murali H; Batra, Harsh V

    2013-12-01

    Immuno capture PCR (IPCR) is a technique capable of detecting the pathogens with high specificity and sensitivity. Rapid and accurate detection of Bacillus anthracis was achieved using anti-EA1 antibodies to capture the cells and two primer sets targeting the virulence factors of the pathogen i.e., protective antigen (pag) and capsule (cap) in an IPCR format. Monoclonal antibodies specific to B. anthracis were generated against extractable antigen 1 protein and used as capture antibody onto 96 well polystyrene plates. Following the binding of the pathogen, the DNA extraction was carried out in the well itself and further processed for PCR assay. We compared IPCR described here with conventional duplex PCR using the same primers and sandwich ELISA using the monoclonal antibodies developed in the present study. IPCR was capable of detecting as few as 10 and 100 cfu ml⁻¹ of bacterial cells and spores, respectively. IPCR was found to be 2-3 logs more sensitive than conventional duplex PCR and the sandwich ELISA. The effect of other bacteria and any organic materials on IPCR was also analyzed and found that this method was robust with little change in the sensitivity in the presence of interfering agents. Moreover, we could demonstrate a simple process of microwave treatment for spore disruption which otherwise are resistant to chemical treatments. Also, the IPCR could clearly distinguish the pathogenic and nonpathogenic strains of B. anthracis in the same assay. This can help in saving resources on unnecessary decontamination procedures during false alarms.

  19. Geochemical Cycle of Radon and its Bioremediation Opportunity from Water Environment: A Review.

    PubMed

    Pradhan, Debabrata; Sukla, Lala Behari; Devi, Niharbala; Acharya, Sridhara

    2018-05-01

    The waterborne or airborne radon causes carcinogenesis in the human bodies due to the continuous decay of α- and β- particles. The health risks related to radioactive radon instigate to develop an advanced technology for its removal from the environment. There are two standard tech-niques, such as aeration and activated carbon filtration, available for its removal. However, both of them face different technological drawbacks resulting in the processes either inefficient or inappropriate for the purpose. There are several technologies utilizing either algae or microorganisms that could be useful in the bioremediation of radon. Some of the algae and microorganisms are examined and found to be tolerated and decontaminated various ionization radiations like α-, β-, and γ- radiations. In a US patent, the microalgae Coccomyxa actinabiotis isolated from a nuclear facility showed the properties of biore-mediation towards radionuclides. They overcome the physiological stress in the extreme environment for their growth due to the evolution under the prolonged influence of high energy radiation. Further, they are stimulated by the process of cloning, genetic transformations and adaptations for the purpose of enhancing the tolerance and decontamination power. Therefore, biotechnological researches have lots of prospects to remove radon from the water environment using algae and microorganisms. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  20. Application of bacteriophages in post-harvest control of human pathogenic and food spoiling bacteria.

    PubMed

    Pérez Pulido, Rubén; Grande Burgos, Maria José; Gálvez, Antonio; Lucas López, Rosario

    2016-10-01

    Bacteriophages have attracted great attention for application in food biopreservation. Lytic bacteriophages specific for human pathogenic bacteria can be isolated from natural sources such as animal feces or industrial wastes where the target bacteria inhabit. Lytic bacteriophages have been tested in different food systems for inactivation of main food-borne pathogens including Listeria monocytogenes, Staphylococcus aureus, Escherichia coli O157:H7, Salmonella enterica, Shigella spp., Campylobacter jejuni and Cronobacter sakazkii, and also for control of spoilage bacteria. Application of lytic bacteriophages could selectively control host populations of concern without interfering with the remaining food microbiota. Bacteriophages could also be applied for inactivation of bacteria attached to food contact surfaces or grown as biofilms. Bacteriophages may receive a generally recognized as safe status based on their lack of toxicity and other detrimental effects to human health. Phage preparations specific for L. monocytogenes, E. coli O157:H7 and S. enterica serotypes have been commercialized and approved for application in foods or as part of surface decontamination protocols. Phage endolysins have a broader host specificity compared to lytic bacteriophages. Cloned endolysins could be used as natural preservatives, singly or in combination with other antimicrobials such as bacteriocins.

Top