Sample records for patients patch tested

  1. Nevirapine patch testing in Thai human immunodeficiency virus infected patients with nevirapine drug hypersensitivity.

    PubMed

    Prasertvit, Piyatida; Chareonyingwattana, Angkana; Wattanakrai, Penpun

    2017-12-01

    Antiretroviral drug hypersensitivity in HIV patients is common. Publications have shown that Abacavir (ABC) patch testing is useful in confirming ABC hypersensitivity in 24-50% of cases with a 100% sensitivity of HLA-B*5701 in patch test positive cases. However, Nevirapine (NVP) patch testing has not been reported. (1) To evaluate the usefulness and safety of NVP patch testing in Thai HIV patients with NVP hypersensitivity. (2) To assess the correlation of positive patch tests with HLA-B*3505. Patients were classified into two groups: (1) study group of 20 HIV NVP hypersensitivity patients and (2) control group of 15 volunteers without NVP hypersensitivity. Both groups were patch tested with purified and commercialized form of NVP in various vehicles. Two HIV patients with NVP hypersensitivity were patch test positive. All controls tested negative. Three HIV patients were positive for HLA-B*3505 and the two patients with positive patch testing were both HLA-B*3505 positive. NVP patch testing in Thai HIV patients is safe and can be used to help confirm the association between NVP and hypersensitivity skin reactions. NVP patch test results significantly correlated with HLA-B*3505. The sensitivity of HLA-B*3505 for positive patch test was 100%. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. A localized flare of dermatitis may render patch tests uninterpretable in some patients with recently controlled widespread dermatitis.

    PubMed

    Magembe, Anna J; Davis, Mark D P; Richardson, Donna M

    2009-01-01

    Patch testing rarely is confounded by localized dermatitis induced in the area being tested (usually the back). Its occurrence renders the interpretation of patch tests impossible. To review our experience of the circumstances in which this phenomenon occurs during patch testing. We retrospectively reviewed patients with this phenomenon who underwent patch testing from January 1, 2002, through June 30, 2006. Of the 3,569 patients tested, 12 (0.34% [9 men and 3 women]) had development of this phenomenon. All patients previously had recent widespread dermatitis that was suppressed temporarily with topical corticosteroids and wet dressings at the time of patch testing. The period between control of the dermatitis and the initiation of patch testing was less than 1 week for all patients. Three patients (25%) had recently discontinued therapy with systemic corticosteroids (less than 1 week earlier). In patients with irritable skin either immediately after widespread dermatitis is controlled or after the cessation of systemic corticosteroid treatment, a flare of dermatitis induced by patch testing may render patch tests unreadable and therefore uninterpretable. To avoid this confounding occurrence, a waiting period between control of widespread dermatitis and initiation of patch testing is advised.

  3. Results of patch testing in 10 patients with peristomal dermatitis.

    PubMed

    Landis, Megan N; Keeling, James H; Yiannias, James A; Richardson, Donna M; Nordberg Linehan, Diane L; Davis, Mark D P

    2012-09-01

    Peristomal dermatitis is a common problem in patients with ostomies that is a source of considerable morbidity. Irritant contact dermatitis is most common, but allergic contact dermatitis can also occur. Because of the lack of published reports on patch testing for this indication, we undertook a retrospective study of patch testing results in patients with suspected peristomal allergic contact dermatitis. We sought to describe our patch testing experience with patients referred with peristomal dermatitis. This was a retrospective review of medical records of patients with ostomies and peristomal dermatitis who underwent patch testing in the Mayo Clinic Departments of Dermatology in Jacksonville, FL; Rochester, MN; and Scottsdale, AZ, during a 10-year period (2000-2010). Ten patients with peristomal dermatitis were referred for patch testing (6 in Minnesota, 2 in Florida, and 2 in Arizona). Patients were patch tested to the materials used in their stoma devices, to the standard series, and in some cases to supplemental series. All 10 had at least one allergic patch test reaction, most commonly to stoma paste (3 of 10 patients). Retrospective nature of study via chart review is a limitation. Patch testing is a useful tool for identification of allergens in patients with peristomal dermatitis. Copyright © 2011 American Academy of Dermatology, Inc. Published by Mosby, Inc. All rights reserved.

  4. Atopy patch test reactions to house dust mites in patients with scabies.

    PubMed

    Taşkapan, Oktay; Harmanyeri, Yavuz

    2005-01-01

    It is well known that the house dust and the scabies mites are related phylogenetically. We therefore performed atopy patch tests with house dust mite antigens (Dermatophagoides pteronyssinus (Dp) and/or Dermatophagoides farinae (Df)) in scabies patients without atopy and healthy controls. We studied 25 men with active scabies and 25 healthy controls. Skin prick tests with standardized house dust mite extract were performed for all patients and controls. An intradermal test procedure was carried out in skin prick test-negative patients, and for controls showing positive atopy patch test to Dp and/or Df. While atopy patch tests were performed directly in all healthy controls, patients with scabies were first treated and on the next day, atopy patch tests were performed. Twenty-two of 25 patients with scabies (88%) had skin prick test and/or intradermal test positivity against house dust mites, whereas 17/25 patients (68%) had atopy patch test positivity against house dust mites (Dp and/or Df). There was no statistically significant difference between skin prick test and/or intradermal test positivity and atopy patch test positivity in a regression analysis (p=0.222). The only statistically significant correlation was between atopy patch test positivity and the extent of scabies involvement (p<0.05). Only few of the healthy controls had positive tests. In this study, we have shown that a positive atopy patch test to house dust mite antigens is not specific for patients with atopic dermatitis, but also occurs in scabies patients without a history of atopic dermatitis.

  5. Environmental contact factors in eczema and the results of patch testing Chinese patients with a modified European standard series of allergens.

    PubMed

    Li, Lin-Feng; Guo, Jing; Wang, Jing

    2004-07-01

    Environmental contact factors in eczema were investigated in China by clinical questionnaire and patch testing patients with a modified European standard series of allergens. 217 consecutive eczema patients were studied. Contact dermatitis (CD) was clinically diagnosed in 30% of the patients. Among the patients patch tested, 46 patients had clinically diagnosed allergic CD (ACD), 20 patients clinically had non-ACD (NACD) (including 16 cases of irritant contact dermatitis, 1 case of phototoxic contact reaction and 3 cases of asteatotic eczema) and 115 patients had clinically suspected ACD. 45 patients (98%) in the ACD group went on to have relevant patch test results. The most common ACD was from metals, fragrance materials, cosmetics and rubber materials. The most common contact allergens identified were nickel, fragrance mix, para-phenylenediamine (PPD), carba mix and thimerosal. No adverse reactions were observed to patch testing, except for pruritus in patch-test-positive patients. The positive rate of patch testing in ACD was much higher than that in NACD (98% versus 15%, P < 0.05, chi(2)-test). 60 (28%) patients had facial dermatitis (FD). Among these, 20 (33%) were confirmed as having ACD. 48 (22%) patients had hand dermatitis (HD). Among these, 7 (15%) were confirmed as having ACD. Fewer patients were confirmed as having ACD in the HD group than in the FD (15% versus 33%, P < 0.05, chi(2)-test). Although the difference was not significant, the total positivity rate in the HD group (55%) was lower than in the other groups. 65 (30%) patients had unclassified endogenous eczema (UEE). The total positive rate of patch testing in the UEE group (56%) was no different from that in the FD or HD groups. However, the relevance of positive patch tests was hard to determine in UEE. These results indicate that CD is common in eczema; relatively more patients with FD have ACD, while other factors, such as irritation, may play more of a role in HD. The total positive rate of patch testing in the UEE group was no different from that in the FD or HD groups, suggesting that patch testing should be stressed in UEE and the relevance of positive patch test results in UEE should be studied further. It is effective and safe to patch eczema patients with a modified European standard series of allergens in China.

  6. Patch-test reaction patterns in patients with a predisposition to atopic dermatitis.

    PubMed

    Brasch, Jochen; Schnuch, Axel; Uter, Wolfgang

    2003-10-01

    Patients with a predisposition to atopic dermatitis often need to be patch tested in order to detect possible contact sensitization. However, it is unknown whether immunologic or other peculiarities of atopic skin are related to altered patch-test reaction patterns. Our study was aimed at answering this question, because patch-test reaction patterns are of considerable practical importance in the reading and interpretation of patch tests. Therefore, we compared patterns of patch-test reactions in patients with a predisposition to atopic dermatitis and in control patients matched for sex, age, reason for testing and test centre. Patch-test results from 9 centres (2322 patients with a disposition to atopic dermatitis and 2126 matched controls) were evaluated retrospectively. All patients were tested with nickel sulfate, fragrance mix, potassium dichromate, lanolin alcohol, formaldehyde and mercury ammonium chloride. Patch tests applied for 1 day with readings on days 1, 2 and 3 were evaluated in order to cover the early phase of the reactions. Not unexpectedly, we found that, compared to the matched controls, patients with a predisposition to atopic dermatitis tended to have more doubtful and irritant reactions on day 1. As a new observation, it turned out that they had less reactions of crescendo pattern and more strong reactions on day 3. All these differences were slight/insignificant. A higher skin irritability in patients with a predisposition to atopic dermatitis is a likely explanation. In conclusion, standard methods for patch testing can be applied in patients with a predisposition to atopic dermatitis, but minor differences in reaction patterns should be considered.

  7. Evaluation and Management of Patch Test-Negative Patients With Generalized Dermatitis.

    PubMed

    Spiker, Alison; Mowad, Christen M

    Patients with generalized dermatitis are common in dermatology practices. Allergic contact dermatitis is often suspected, and patients frequently undergo patch testing. When the patch testing result is negative, further evaluation and management of these patients are challenging. The purpose of this study was to survey members of the American Contact Dermatitis Society regarding the evaluation and management of patch test-negative patients with generalized dermatitis. Generalized dermatitis was the most common term identified for patch test-negative patients with diffuse dermatitis. After having negative expanded patch testing results, most physicians proceeded with additional testing including skin biopsy, complete blood cell count with differential, and liver and renal function tests. The most commonly used systemic treatment is prednisone, followed by methotrexate. Narrow-band ultraviolet B (UVB) is the most commonly used light source. Antihistamines are frequently prescribed. Food allergy is not felt to be causative. This cohort of patients experiences significant impairment in quality of life, stress on personal relationships, and time off work. The management of patch test-negative patients with generalized dermatitis is challenging. This study provides insight into management of these complex patients. It also demonstrates practice gaps in the management of these patients, indicating a need for further studies to direct the evaluation and management of this patient population.

  8. A Pragmatic Approach to Patch Testing Atopic Dermatitis Patients: Clinical Recommendations Based on Expert Consensus Opinion.

    PubMed

    Chen, Jennifer K; Jacob, Sharon E; Nedorost, Susan T; Hanifin, Jon M; Simpson, Eric L; Boguniewicz, Mark; Watsky, Kalman L; Lugo-Somolinos, Aida; Hamann, Carsten R; Eberting, Cheryl Lee; Silverberg, Jonathan I; Thyssen, Jacob P

    2016-01-01

    Allergic contact dermatitis (ACD) may complicate the clinical course of atopic dermatitis (AD), and patch testing remains the criterion standard for diagnosing ACD. To date, there have been no guidelines or consensus recommendations on when and how to patch test individuals with AD. Failure to patch test when appropriate may result in overlooking an important and potentially curable complicating comorbidity. In this article, we present consensus recommendations regarding when to perform patch testing in the AD patient, best practices, and common pitfalls. Patch testing should be considered in AD patients with dermatitis that fails to improve with topical therapy; with atypical/changing distribution of dermatitis, or pattern suggestive of ACD; with therapy-resistant hand eczema in the working population; with adult- or adolescent-onset AD; and/or before initiating systemic immunosuppressants for the treatment of dermatitis. A suggested patch testing algorithm for AD patients is provided.

  9. Allergic contact dermatitis from ophthalmic products: can pre-treatment with sodium lauryl sulfate increase patch test sensitivity?

    PubMed

    Corazza, Monica; Virgili, Annarosa

    2005-05-01

    In patients suspected of allergic contact dermatitis because of topical ophthalmic medicaments, patch tests performed with patients' own products are often negative. The irritant anionic surfactant sodium lauryl sulfate (SLS) may alter the stratum corneum and increase antigen penetration. Pre-treatment of the skin with SLS 0.5% for 24 h was performed in the sites of patch tests with patients' own products in 15 selected patients. In patients previously negative to their own products tested with conventional patch tests, SLS pre-treatment showed 6 new relevant positive reactions and induced a stronger positive reaction in 1 patient. SLS pre-treatment could be proposed as an alternative promising method, which may increase sensitivity of patch tests with patients' own products.

  10. Photo-patch and patch tests in patients with dermatitis over the photo-exposed areas: A study of 101 cases from a tertiary care centre in India.

    PubMed

    Sharma, Vinod Kumar; Bhari, Neetu; Wadhwani, Ashok Roopchand; Bhatia, Riti

    2018-02-01

    Many patients with dermatitis over photo-exposed body areas are positive to many contact allergens and have a pre-existing allergic contact dermatitis. This study included patients who presented to a tertiary centre in India with dermatitis on photo-exposed body areas suspected of chronic actinic dermatitis. Their detailed histories were recorded and cutaneous and systemic examinations were performed. Patch testing was done in all the patients and photo-patch testing was carried out in 86 patients. Altogether 101 patients were included (69 males, 32 females). The most common presentation was lichenified hyperpigmented plaques on the photo-exposed sites. Photosensitivity was recorded in 64 (63%) patients and summer exacerbation in 52 (52%). Exposure to the Parthenium hysterophorus weed was recorded in 70 (69%) patients, 27 (26.7%) had a history of hair dye application and 20 (20%) had a history of atopy. Photo-patch test was positive in 11 (12.8%) patients and patch testing was positive in 71 (70%). Parthenium hysterophorus was the most common allergen implicated and was positive in three (4%) photo-patch and 52 (52%) patch tests. Other positive photo-patch test allergens were perfume mix, balsam of Peru, thiuram mix, Compositae mix and promethazine hydrochloride. Other common patch test allergens were parthenolide, colophony, fragrance mix and p-phenylenediamine (PPD) base. In the Indian population parthenium and perfume mix are the most common photoallergens in patients with dermatitis over photo-exposed areas, while parthenium, colophony, fragrance mix and PPD are the common positive allergens. © 2016 The Australasian College of Dermatologists.

  11. Use of patch testing for the diagnosis of abacavir-related hypersensitivity reaction in HIV patients.

    PubMed

    Giorgini, S; Martinelli, C; Tognetti, L; Carocci, A; Giuntini, R; Mastronardi, V; Torricelli, F; Leoncini, F; Lotti, T

    2011-01-01

    The use of antiretroviral drug abacavir (ABC) has been often associated with cutaneous hypersensitivity reactions, the majority being severe. The present study discusses the issues of patch testing associated with pharmacogenetic screening in light of the development of abacavir hypersensitivity reactions (HSRs). The present authors classified 100 patients into three groups: 20 patients (group A) had experienced a hypersensitivity reaction when treated with highly active antiretroviral therapy (HAART) including ABC; 60 HIV-positive patients (group B) were receiving HAART scheme including ABC; 20 HIV-negative patients acted as control group (group C). Patients of group A and B were patch tested with ABC as such, then with an ABC extract diluted to 1 and 10% in petrolatum. Group C patients underwent patches with petrolatum only. A biopsy of the lesion was performed in those patients who showed a positive skin reaction. All patients had been tested for HLA-B5701. A correlation between positive ABC-patch testing and HLA-B5701 was found in 50% of patients enrolled in group A, while in group B and C, all patients tested negative for both genetic marker and ABC-patch testing. Histopathology findings confirmed a vigorous CD4+ and CD8+ cellular response that is compatible with HSR. Patch testing is a safe and sensitive method that can be used for to confirm or exclude any correlation between abacavir and hypersensitivity skin reactions in patients who have been previously treated with abacavir during HAART. Correlation between patch test, immunohistochimical, and genetic tests results shows that genetic testing increases the possibility to identify patients with a true reaction. © 2012 Wiley Periodicals, Inc.

  12. Skin irritability to sodium lauryl sulfate is associated with increased positive patch test reactions.

    PubMed

    Schwitulla, J; Brasch, J; Löffler, H; Schnuch, A; Geier, J; Uter, W

    2014-07-01

    As previous observations have indicated an inter-relationship between irritant and allergic skin reactions we analysed data of synchronous allergen and sodium lauryl sulfate (SLS) patch tests in terms of a relationship between SLS responsiveness and allergic patch test reactions. To analyse differences in terms of allergen-specific and overall reaction profiles between patients with vs. those without an irritant reaction to SLS. Clinical data of 26 879 patients patch tested from 2008 to 2011 by members of the Information Network of Departments of Dermatology were analysed. After descriptive analyses, including the MOAHLFA index, the positivity ratio and the reaction index, a negative binomial hurdle model was adopted to investigate the correlation between SLS reactivity and positive patch test reactions. Men, patients aged ≥ 40 years and patients with an occupational dermatitis background were over-represented in the SLS-reactive group. Patients with an irritant reaction to SLS showed a higher proportion of weak positive reactions, as well as more questionable and irritant reactions to contact allergens than patients not reactive to SLS. The risk of an additional positive patch test reaction increased by 22% for SLS-reactive patients compared with those who were SLS negative. The marked association between SLS reactivity and the number of positive reactions in patch test patients may be due to nonspecific increased skin reactivity at the moment of patch testing only. However, increased SLS reactivity could also be due to longer-lasting enhanced skin irritability, which may have promoted (poly-)sensitization. Further studies, for example with longitudinal data on patients repeatedly patch tested with SLS and contact allergens, are necessary. © 2014 British Association of Dermatologists.

  13. Selective versus routine patch metal allergy testing to select bar material for the Nuss procedure in 932 patients over 10years.

    PubMed

    Obermeyer, Robert J; Gaffar, Sheema; Kelly, Robert E; Kuhn, M Ann; Frantz, Frazier W; McGuire, Margaret M; Paulson, James F; Kelly, Cynthia S

    2018-02-01

    The aim of the study was to determine the role of patch metal allergy testing to select bar material for the Nuss procedure. An IRB-approved (11-04-WC-0098) single institution retrospective, cohort study comparing selective versus routine patch metal allergy testing to select stainless steel or titanium bars for Nuss repair was performed. In Cohort A (9/2004-1/2011), selective patch testing was performed based on clinical risk factors. In Cohort B (2/2011-9/2014), all patients were patch tested. The cohorts were compared for incidence of bar allergy and resultant premature bar loss. Risk factors for stainless steel allergy or positive patch test were evaluated. Cohort A had 628 patients with 63 (10.0%) selected for patch testing, while all 304 patients in Cohort B were tested. Over 10years, 15 (1.8%) of the 842 stainless steel Nuss repairs resulted in a bar allergy, and 5 had a negative preoperative patch test. The incidence of stainless steel bar allergy (1.8% vs 1.7%, p=0.57) and resultant bar loss (0.5% vs 1.3%, p=0.23) was not statistically different between cohorts. An allergic reaction to a stainless steel bar or a positive patch test was more common in females (OR=2.3, p<0.001) and patients with a personal (OR=24.8, p<0.001) or family history (OR=3.1, p<0.001) of metal sensitivity. Stainless steel bar allergies occur at a low incidence with either routine or selective patch metal allergy testing. If selective testing is performed, it is advisable in females and patients with a personal or family history of metal sensitivity. A negative preoperative patch metal allergy test does not preclude the possibility of a postoperative stainless steel bar allergy. Level III Treatment Study and Study of Diagnostic Test. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Patch Test Negative Generalized Dermatitis.

    PubMed

    Spiker, Alison; Mowad, Christen

    2016-01-01

    Allergic contact dermatitis is a common condition in dermatology. Patch testing is the criterion standard for diagnosis. However, dermatitis is not always caused by an allergen, and patch testing does not identify a culprit in every patient. Generalized dermatitis, defined as eczematous dermatitis affecting greater than 3 body sites, is often encountered in dermatology practice, especially patch test referral centers. Management for patients with generalized dermatitis who are patch test negative is challenging. The purpose of this article is to outline an approach to this challenging scenario and summarize the paucity of existing literature on patch test negative generalized dermatitis.

  15. Contact Urticaria to Nickel: A Series of 11 Patients Who Were Prick Test Positive and Patch Test Negative to Nickel Sulfate 2.5% and 5.0.

    PubMed

    Saluja, Sandeep S; Davis, Crystal L; Chong, Tracie A; Powell, Douglas L

    2016-01-01

    Nickel is the most common allergen found by patch testing; however, not all cases of nickel allergy are type 4 (delayed) allergies. Contact urticaria (CU) to nickel (immediate reaction) has been reported; however, few seem to evaluate it as per a recent published survey of American Contact Dermatitis Society members. The aim of the study was to present a series of patients who had clinical histories suggestive of nickel allergy and yet were patch test negative but prick test positive to nickel, thus demonstrating CU. We reviewed the charts of 11 patients who were patch test negative but prick test positive. All 11 patients demonstrated evidence of CU by prick testing (or closed chamber test in 1). None were patch test positive to nickel 2.5% or 5.0%. Four patients' histories mentioned reactions to various jewelry/earrings within minutes, whereas 2 histories mentioned reacting within a few hours. These histories are consistent with CU. Others (except 1 patient) recalled reacting to jewelry/earrings but did not recall a time frame. Our series suggests that CU to nickel may be far more common than anticipated and should be evaluated with prick testing when patients' history suggests nickel allergy and yet they are patch test negative.

  16. Our experience with atopy patch tests with aeroallergens.

    PubMed

    Celakovská, Jarmila; Ettlerová, Kvetuse; Ettler, Karel; Vanecková, Jaroslava

    2013-01-01

    Aim of our study was to evaluate the importance of atopy patch testing with aeroallergens as a diagnostic method in patients suffering from atopic dermatitis. The complet dermatological and allergological examinations were performed in 29 patients; 10 men, 19 women with the average age of 27.8 years, min. 17, max. 57 years; with the median SCORAD 24.2 points, s.d. 13.3 points. Wormwood, grass, dog dander, cat dander, dermatophagoides pharinae, dermatophagoides pteronyssinus and birch pollen were examined in diagnostic procedures. Skin prick tests, specific IgE were examined; the atopy patch tests were performed with aeroallergens for skin prick tests in concentration 1 x skin prick tests. Specific IgE and skin prick tests to one or more tested aeroallergens were positive altogether in 27 patients; atopy patch tests were positive only in one of these patients. For atopy patch testing with aeroallergens the concentration of 1 x skin prick tests is low to confirme the eczematic reaction in patients suffering from allergy to inhallant allergens.

  17. Patch testing with thin-layer chromatograms of chamomile tea in patients allergic to sesquiterpene lactones.

    PubMed

    Lundh, Kerstin; Gruvberger, Birgitta; Möller, Halvor; Persson, Lena; Hindsén, Monica; Zimerson, Erik; Svensson, Ake; Bruze, Magnus

    2007-10-01

    Patients with contact allergy to sesquiterpene lactones (SLs) are usually hypersensitive to Asteraceae plant products such as herbal teas. The objective of this study was to show sensitizers in chamomile tea by patch testing with thin-layer chromatograms. Tea made from German chamomile was separated by thin-layer chromatography. Strips of the thin-layer chromatograms were used for patch testing SL-positive patients. 15 (43%) of 35 patients tested positively to 1 or more spots on the thin-layer chromatogram, with many individual reaction patterns. Patch testing with thin-layer chromatograms of German chamomile tea showed the presence of several allergens.

  18. Atopy patch tests in young adult patients with atopic dermatitis and controls: dose-response relationship, objective reading, reproducibility and clinical interpretation.

    PubMed

    Bygum, Anette; Mortz, Charlotte Gotthard; Andersen, Klaus Ejner

    2003-01-01

    The clinical interpretation and reproducibility of atopy patch tests was studied in 23 selected young adult patients with atopic dermatitis and 25 healthy controls using standard inhalant allergens. Non-invasive measurements were used for objective assessment of test reactions and the participants were retested after 6 weeks. Ten of 19 (53%) evaluable patients with atopic dermatitis had at least one positive atopy patch test. However, there was no clear clinical relevance of the atopy patch test results when related to patient history and distribution of dermatitis. Reproducible and dose-dependent results were obtained with Dermatophagoides pteronyssinus, grass and cat with a reproducibility rate of 0.69 to 0.81 in patients and 0.60-0.96 in controls. A unique finding was a significant positive correlation between a positive atopy patch test, allergen dose and increase in transepidermal water loss and erythema, while measurement of capacitance did not distinguish between positive and negative reactions. The results of the present study do not support the routine use of atopy patch tests in the evaluation of adult patients with atopic dermatitis.

  19. Patch testing custom isocyanate materials from the workplace.

    PubMed

    Burrows, Dianne; Houle, Marie-Claude; Holness, D Linn; DeKoven, Joel; Skotnicki, Sandy

    2015-01-01

    Patch testing with standard trays of commercially available allergens is the current practice for investigating suspected cases of isocyanate-induced allergic contact dermatitis (ACD). In some facilities, these standard trays are further supplemented with custom preparations of isocyanate-containing materials. The aim was to determine whether added value exists in patch testing patients to custom isocyanate preparations in suspected cases of ACD. We performed a retrospective analysis of 11 patients referred to our specialty clinic between January 2003 and March 2011 for suspected patients of ACD who had custom testing with isocyanate materials from their workplace. In addition to standard trays of allergens, all patients were patch tested with custom isocyanate materials from their workplaces. Three (27%) of 11 patients showed an added value in testing to custom isocyanate allergens. Of these 3 patients, one had a reaction that reinforced positive reactions to the standard isocyanate tray, but the other 2 (18%) had no reactions to any of the commercially available allergens. Because of the high proportion of reactions (27%), we recommend the use of custom testing to workplace isocyanate products as a supplement to current standard patch testing procedures.

  20. Prevalence of benzocaine and lidocaine patch test sensitivity in Denmark: temporal trends and relevance.

    PubMed

    Thyssen, Jacob P; Engkilde, Kåre; Menné, Torkil; Johansen, Jeanne D

    2011-08-01

    BACKGROUND. Allergens included in the European baseline series should result in positive patch test reactions in at least 1% of a patch test population. Inclusion of local anaesthetics other than benzocaine in the baseline series has previously been debated. To investigate temporal trends of benzocaine and lidocaine allergy in dermatitis patients who underwent routine patch testing in a tertiary referral patch test centre, and to clarify and discuss whether lidocaine and benzocaine should be included in routine series. Dermatitis patients who underwent routine patch testing with benzocaine as a part of the European baseline series between 1985 and 2010 (n = 19 347) and dermatitis patients who underwent routine patch testing with lidocaine between 1994 and 2001 (n = 6265) and between 2007 and 2009 (n = 1360) were included. The overall prevalences of contact allergy were 0.5% (benzocaine), 0.3% (lidocaine for the period 1994-2001), and 0.14% (lidocaine for the period 2007-2009). Current relevance was observed in 10% of those with benzocaine allergy and in 5% of those with lidocaine allergy. Benzocaine and lidocaine allergy is infrequent in Danish dermatitis patients. Lidocaine should only be used for aimed testing, and benzocaine should be removed from the baseline series used in Denmark. © 2011 John Wiley & Sons A/S.

  1. PATIENTS' KNOWLEDGE OF MEDICAL PATCHES IN HUNGARY.

    PubMed

    Somogyi, Orsolya; Zelko, Romana

    2016-11-01

    Transdermal therapy with medical patches is a simple possibility in home medication. As the correct use of patches has a decisive impact from the point of its modulator effect.A questionnaire survey was developed to explore level of patients' knowledge of the correct use of transdermal patches. A survey was administered in thirteen Hungarian community pharmacies from October of 2012 to May of 2015. Most of the participants, men and women over 18 years of age (n = 233), used major analgesic patches (fentanyl); the remainder were given nitroglycerin, NSAID analgesics patches during the survey. For the hypothesis testing it was assumed that men were more likely to use a razor for skin depilation before patch application than women as their denser pelage hinders patch adhesion. The hypothesis testing showed no significant gender difference in razor use (X² = 0.201; p = 0.654). Pharmacists should direct patients to avoid using soap for skin cleansing before patch application because only 22 percent of the participants always avoided its use. Since only 9 tests were flawless from 233 completed questionnaires. Many patients do not understand how to correctly apply a transdermal dosage patch. Pharmacists should teach their correct application based on results.

  2. Experimental patch testing with chromium-coated materials.

    PubMed

    Bregnbak, David; Thyssen, Jacob P; Jellesen, Morten S; Zachariae, Claus; Johansen, Jeanne D

    2017-06-01

    Chromium coatings on metal alloys can be decorative, and prevent corrosion and metal ion release. We recently showed that handling of a chromium-containing disc resulted in chromium deposition on the skin. To examine patch test reactivity to chromium-coated discs. We included 15 patients: 10 chromium-allergic patients, and 5 patients without chromium allergy. All were patch tested with potassium dichromate, cobalt chloride, nickel sulfate, and nine different metallic discs. The chromium-allergic patients were also patch tested with serial dilutions of potassium dichromate. Positive/weaker reactions were observed to disc B (1 of 10), disc C (1 of 10), and disc D, disc E, and disc I (4 of 10 each). As no controls reacted to any of the discs, the weak reactions indicate allergic reactions. Positive patch test reactions to 1770 ppm chromium(VI) in the serial dilutions of potassium dichromate were observed in 7 of 10 patients. When the case group was narrowed down to include only the patients with a current positive patch test reaction to potassium dichromate, elicitation of dermatitis by both chromium(III) and chromium(VI) discs was observed in 4 of 7 of patients. Many of the patients reacted to both chromium(III) and chromium(VI) surfaces. Our results indicate that both chromium(VI) and chromium(III) pose a risk to chromium-allergic patients. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Investigation of contact allergy to dental materials by patch testing.

    PubMed

    Rai, Reena; Dinakar, Devina; Kurian, Swetha S; Bindoo, Y A

    2014-07-01

    Dental products are widely used by patients and dental personnel alike and may cause problems for both. Dental materials could cause contact allergy with varying manifestations such as burning, pain, stomatitis, cheilitis, ulcers, lichenoid reactions localized to the oral mucosa in patients, and hand dermatitis in dental personnel. Patch testing with the dental series comprising commonly used materials can be used to detect contact allergies to dental materials. This study aimed to identify contact allergy among patients who have oral mucosal lesions after dental treatment and among dental personnel who came in contact with these materials. Twenty patients who had undergone dental procedures with symptoms of oral lichen planus, oral stomatitis, burning mouth, and recurrent aphthosis, were included in the study. Dental personnel with history of hand dermatitis were also included in the study. Patch testing was performed using Chemotechnique Dental Series and results interpreted as recommended by the International Contact Dermatitis Research Group (ICDRG). Out of 13 patients who had undergone dental treatment/with oral symptoms, six patients with stomatitis, lichenoid lesions, and oral ulcers showed positive patch tests to a variety of dental materials, seven patients with ulcers had negative patch tests, seven dental personnel with hand dermatitis showed multiple allergies to various dental materials, and most had multiple positivities. The patch test is a useful, simple, noninvasive method to detect contact allergies among patients and among dental personnel dealing with these products. Long term studies are necessary to establish the relevance of these positive patch tests by eliminating the allergic substances, identifying clinical improvement, and substituting with nonallergenic materials.

  4. FOOT ECZEMA: THE ROLE OF PATCH TEST IN DETERMINING THE CAUSATIVE AGENT USING STANDARD SERIES

    PubMed Central

    Priya, K S; Kamath, Ganesh; Martis, Jacintha; D, Sukumar; Shetty, Narendra J; Bhat, Ramesh M; Kishore, B Nanda

    2008-01-01

    Foot dermatitis refers to the predominant involvement of feet in the eczematous process. This study is undertaken to determine the clinical pattern and causative agent in foot eczema and to evaluate the role of patch testing in determining the causative agent of foot eczema. Data was collected from 50 patients with foot eczema, who attended the out-patient department. The patch test was performed using Indian standard series. Patch test was positive in 88% of the patients. The most common site affected was the dorsal aspect of the foot (48%) and scaly plaque was the predominant morphological pattern. The highest number of patients (24%) showed positive reactions to mercaptobenzothiazole (MBT) and the lowest (4%) to neomycin sulfate. Rubber and rubber chemicals have been reported worldwide to be the most common sensitizer causing foot eczema. Thus, patch test has a major role in finding out the cause of foot eczema. PMID:19881990

  5. Patch test results with patients' own perfumes, deodorants and shaving lotions: results of the IVDK 1998-2002.

    PubMed

    Uter, W; Geier, J; Schnuch, A; Frosch, P J

    2007-03-01

    Assessment of the value of patch testing patients' own perfumes, eau de toilette, deodorants and shaving lotions with regard to diagnosing contact allergy to fragrances, and an analysis of the spectrum of concurrent patch test reactions to single fragrance allergens. Data of the Information Network of Departments of Dermatology (IVDK; http://www.ivdk.org) regarding patch test results with above products brought in by the patient, considered as possible cause of contact dermatitis, were retrospectively analysed. Between 1998 and 2002, 1468 patients were patch tested with 2557 single products (deodorants, n = 1094; eau de toilette, n = 598; perfume, n = 530; and pre- or after-shave, n = 325; remainder not classifiable), mostly 'as is'. Positive reactions were observed in 129 patients (to 191 products). In 58 of these patients, no further patch test reactions to the fragrance mix (FM-I), Myroxylon pereirae resin (balsam of Peru) or 4-(4-hydroxy-4-methyl-pentyl)-3-cyclohexencarboxaldehyde (e.g. Lyral(R)) were found. A strong association between contact sensitivity to the above commercial allergens and positive reactions to products was observed. Some single compounds such as ylang-ylang oil, propolis and especially oak moss absolute are important allergens in the 'perfume-positive' subgroup, but less in a subgroup positive to own deodorants. Patch testing this scope of products, brought in by the patient, can be regarded as a simple, safe and effective method to diagnose clinically relevant contact sensitization - the more so, as the composition of such products is ever-changing, and the sensitivity of established 'screening allergens' is thus insufficient.

  6. Risk factors and common contact allergens in facial allergic contact dermatitis patients.

    PubMed

    Kasemsarn, Pranee; Iamphonrat, Thanawan; Boonchai, Waranya

    2016-04-01

    Facial dermatitis is commonly encountered in dermatologic practice. It is sometimes difficult to manage because its causative factors may be multiple and difficult to diagnose. This study was designed to identify the characteristics, patch test results, and final diagnoses of facial dermatitis patients who were referred to a contact dermatitis clinic and to identify factors associated with facial allergic contact dermatitis (ACD). We retrospectively reviewed case records of facial dermatitis patients who underwent patch testing at the clinic during the period from July 2006 to June 2011. Of the 891 patients patch-tested, 244 (27.4%) had facial dermatitis. Female patients were 9.1 times more predominant than male patients. The mean ± standard deviation age of patients was 37.3 ± 14.8 years. A total of 199 (81.6%) patients demonstrated at least one positive reaction to a patch test, 66.7% of which were clinically relevant. Allergic contact dermatitis was diagnosed in 45.5% of patients. Independent factors predisposing towards facial dermatitis were female sex, having a previous history of cosmetic allergy, a positive patch test reaction to hairdressing product-related allergens, and a positive allergic reaction to preservative allergens. The prevalence of facial dermatitis was 27.4%. Almost half of all patients with facial dermatitis demonstrated ACD. Factors associated with facial ACD were female gender, a history of cosmetic allergy, and positive patch test reactions to hairdressing product-related allergens and preservatives. © 2015 The International Society of Dermatology.

  7. Is there a role of food additives in recurrent aphthous stomatitis? A prospective study with patch testing.

    PubMed

    Gülseren, Duygu; Hapa, Asli; Ersoy-Evans, Sibel; Elçin, Gonca; Karaduman, Ayşen

    2017-03-01

    Recurrent aphthous stomatitis (RAS) is a common disease of the oral mucosa with an unknown etiology. This study aimed to determine if food additives play a role in the etiology of RAS as well as to determine if patch testing can be used to detect which allergens cause RAS. This prospective study included 24 patients with RAS and 22 healthy controls. All the participants underwent patch testing for 23 food additives. In total, 21 (87.5%) RAS patients and 3 (13.6%) controls had positive patch test reactions to ≥1 allergens; the difference in the patch test positivity rate between groups was significant (P < 0.05). The most common allergen that elicited positive patch test results in the patient group was cochineal red (n = 15 [62.5%]), followed by azorubine (n = 11 [45.8%]) and amaranth (n = 6 [25%]). The present findings show that food additives might play a role in the etiology of RAS and that patch testing could be a method for determining the etiology of RAS. © 2016 The International Society of Dermatology.

  8. Investigation of contact allergy to dental materials by patch testing

    PubMed Central

    Rai, Reena; Dinakar, Devina; Kurian, Swetha S.; Bindoo, Y. A.

    2014-01-01

    Background: Dental products are widely used by patients and dental personnel alike and may cause problems for both. Dental materials could cause contact allergy with varying manifestations such as burning, pain, stomatitis, cheilitis, ulcers, lichenoid reactions localized to the oral mucosa in patients, and hand dermatitis in dental personnel. Patch testing with the dental series comprising commonly used materials can be used to detect contact allergies to dental materials. Aim: This study aimed to identify contact allergy among patients who have oral mucosal lesions after dental treatment and among dental personnel who came in contact with these materials. Materials and Methods: Twenty patients who had undergone dental procedures with symptoms of oral lichen planus, oral stomatitis, burning mouth, and recurrent aphthosis, were included in the study. Dental personnel with history of hand dermatitis were also included in the study. Patch testing was performed using Chemotechnique Dental Series and results interpreted as recommended by the International Contact Dermatitis Research Group (ICDRG). Results: Out of 13 patients who had undergone dental treatment/with oral symptoms, six patients with stomatitis, lichenoid lesions, and oral ulcers showed positive patch tests to a variety of dental materials, seven patients with ulcers had negative patch tests, seven dental personnel with hand dermatitis showed multiple allergies to various dental materials, and most had multiple positivities. Conclusion: The patch test is a useful, simple, noninvasive method to detect contact allergies among patients and among dental personnel dealing with these products. Long term studies are necessary to establish the relevance of these positive patch tests by eliminating the allergic substances, identifying clinical improvement, and substituting with nonallergenic materials. PMID:25165644

  9. Utility of patch testing for patients with drug eruption.

    PubMed

    Ohtoshi, S; Kitami, Y; Sueki, H; Nakada, T

    2014-04-01

    Patch testing is less dangerous than oral provocation testing for identification of the causative drug for patients with drug eruption; however, its usefulness for such identification is controversial. To clarify the rates of positive patch testing for patients with drug eruption, classified by causative drugs and clinical features. We analysed results during the period 1990-2010 for 444 patients (151 men, 293 women; mean ± SD age 49.9 ± 18.6 years) who were tested for drug eruption. In the patient group, there were 309 people (69.1%) with maculopapular eruption and 31 (6.9%) with severe drug eruption. The test materials were applied to the back and left for 2 days under occlusion, then results were assessed by the International Contact Dermatitis Research Group (ICDRG) scoring system 3 days after application. Reactions of + to +++ were regarded as positive. Of the 444 patients, 100 (22.4%) had a positive patch test result to a suspected drug. Positive rates were 23.6% and 20.0% for maculopapular eruption and fixed drug eruption, respectively. The class of materials to which most patients reacted positively was contrast medium (n = 53; 41.1%), followed by drugs acting on the central nervous system (n = 18; 28.6%). In the latter group, 16 of the 18 patients were positive to antiepileptics. Positive rates depend on the causative drug rather than the clinical features of the drug eruption. Patch testing is useful when contrast medium or antiepileptics are suspected to be the causative drugs. However, standardization of patch test materials and method of reading is needed, as well as guidelines regarding when testing should be performed. Although patch testing for drug eruption has significant potential, it requires further validation. © 2014 The Authors. Clinical and Experimental Dermatology published by John Wiley & Sons Ltd on behalf of British Association of Dermatologists.

  10. Contact allergy to chlorhexidine in a tertiary dermatology clinic in Denmark.

    PubMed

    Opstrup, Morten S; Johansen, Jeanne D; Zachariae, Claus; Garvey, Lene H

    2016-01-01

    Chlorhexidine is a widely used disinfectant in the healthcare setting and in cosmetic products. A high prevalence of chlorhexidine contact allergy was reported in Denmark in the 1980s (2.0-5.4% of patients patch tested). It is unknown whether the prevalence is still high, which products cause the contact allergy, and whether accidental re-exposure occurs in some patients. To estimate the prevalence of chlorhexidine contact allergy in a tertiary dermatology clinic in Denmark; to investigate whether patch testing with both chlorhexidine diacetate and chlorhexidine digluconate is necessary; to investigate how many patients have combined immediate-type allergy and contact allergy; and to identify which products cause chlorhexidine contact allergy, and whether patients are accidentally re-exposed. This was a retrospective study including all patients patch tested with chlorhexidine during 2003-2013 at the Department of Dermato-Allergology at Copenhagen University Hospital Gentofte (n = 8497). All patients with a positive patch test reaction to chlorhexidine were sent a questionnaire comprising questions about the cause of the allergy and re-exposure. Overall, 1.0% (n = 82) of all patients patch tested with chlorhexidine were positive. A decrease in the prevalence was observed over time, most likely because of lowering of the test concentration from 1.0 to 0.5% in 2008. Of the 82 patients, 28 (0.3%) had positive test reactions to both chlorhexidine salts, 43 (0.5%) had a positive test reaction only to chlorhexidine diacetate, and 11 (0.1%) had a positive test reaction to chlorhexidine digluconate. Three patients were both patch test-positive and prick test-positive. A known cause of the allergy was reported by 19 patients (40%) in the questionnaire: the products used in the healthcare setting were mainly reported, but some reported cosmetic products. Accidental re-exposure was reported by 15 patients (32%), of whom 13 reported symptoms. The prevalence of chlorhexidine contact allergy does not seem to be higher in Denmark than in other European countries. Patch testing with both chlorhexidine diacetate and chlorhexidine digluconate may be beneficial. Testing for immediate-type allergy in patients with a positive patch test reaction to chlorhexidine is recommended. Chlorhexidine-containing products used in the healthcare setting and in cosmetics are potential causes of sensitization and allergy. Re-exposure is common, highlighting the fact that patients and healthcare personnel need to be well informed about possible sources of exposure. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Finding the optimal patch test material and test concentration to detect contact allergy to geraniol.

    PubMed

    Hagvall, Lina; Karlberg, Ann-Therese; Christensson, Johanna B

    2013-04-01

    Geraniol is a commonly used fragrance terpene, and is tested in the baseline series in fragrance mix I. Geraniol is a pro-hapten and a pre-hapten, and sensitizers are formed in the autoxidation and skin metabolism of geraniol. Previous patch testing with air-exposed (oxidized) geraniol has suggested that oxidized geraniol could be a better marker for contact allergy to geraniol than pure geraniol. To find the optimal patch test substance and concentration for detecting contact allergy to geraniol. Six hundred and fifty-five patients were patch tested with pure and oxidized geraniol at 4.0%, 6.0% and 11.0% in petrolatum. Before patch testing, the irritant properties of pure and oxidized geraniol were studied in 27 patients at 2.5%, 5.0%, 10.0% and 20.0% pet. Pure geraniol detected positive reactions in 0.15-1.1% of the patients, and oxidized geraniol detected positive reactions in 0.92-4.6% of the patients. Reactions to pure geraniol in patients not reacting to oxidized geraniol indicated metabolic activation of geraniol. Neither pure nor oxidized geraniol gave significant irritant reactions. Increasing the test concentrations of pure and oxidized geraniol enables the detection of more cases of contact allergy. Oxidized geraniol detects more patients than pure geraniol, but patch testing with only oxidized geraniol does not detect all cases of contact allergy to geraniol. © 2013 John Wiley & Sons A/S.

  12. Effects of time and recall of patch test results on quality of life (QoL) after testing. Cross-sectional study analyzing QoL in hand eczema patients 1, 5 and 10 years after patch testing.

    PubMed

    Jamil, Wasim N; Lindberg, Magnus

    2017-08-01

    Patch testing can improve health-related quality of life (HRQOL). To study the impact on HRQOL of elapsed time after patch testing (1-10 years), and how the outcome of testing and patients' recall affects HRQOL. The Dermatology Life Quality Index (DLQI) questionnaire was sent to all patients (aged 18-65 years) who were patch tested for suspected contact allergy in 2009, 2005 and 2000 at the Department of Dermatology in Örebro. The response rate was 51% (n = 256). The DLQI score was significantly lower at 10 years after patch testing (mean DLQI = 5.5) than at 1 year (mean DLQI = 7.7). Work was the most impaired aspect. A binary logistic model showed that only time (10 years after testing) was associated with no effect, a light effect or a moderate effect (DLQI < 10) on HRQOL. No such association was seen for patients with negative or positive test results concerning full recall, partial recall or no recall of diagnosed allergens. Although there was an improvement in HRQOL over time, the work aspect remained a major problem. The improvement was not affected by the outcome of testing and patients' recall of test results. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Monitoring contact sensitization to p-phenylenediamine (PPD) by patch testing with PPD 0.3% in petrolatum.

    PubMed

    Geier, Johannes; Ballmer-Weber, Barbara K; Dickel, Heinrich; Frosch, Peter J; Bircher, Andreas; Weisshaar, Elke; Hillen, Uwe

    2013-07-01

    Being a contact allergen of general relevance, p-phenylenediamine (PPD) is patch tested in the baseline series. However, PPD 1% in petrolatum may actively sensitize. Patch testing with PPD at 0.35% pet. proved to be safe, as far as active sensitization is concerned. To determine whether PPD 0.3% pet. reliably detects PPD sensitization. Patch testing with PPD 0.3% pet. and 1% pet. synchronously was performed in consecutive patients in a multicentre study within the Information Network of Departments of Dermatology. Altogether, 2042 patients were patch tested. PPD 1% pet. yielded 6.0% positive reactions (n = 123), and PPD 0.3% pet. yielded 4.7% (n = 95). The synchronous reproducibility of PPD reactions was similar as known from parallel patch tests with identical PPD concentrations. The diagnostic properties of PPD 0.3% pet. expressed as reaction index and positivity ratio were good. Of the 123 patients reacting to PPD 1% pet., 32 (26%) had no positive reaction to PPD 0.3% pet. In 22 of these 32 patients (69%), no clinical relevance could be found. As patch testing with PPD 0.3% pet. is reliable according to our results, we recommend replacing PPD 1% pet. in the baseline series with PPD 0.3% pet. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Patch Testing in Patients with Suspected Footwear Dermatitis: A Retrospective Study.

    PubMed

    Garg, Taru; Agarwal, Soumya; Rana, Shiwangi; Chander, Ram

    2017-01-01

    Footwear dermatitis represents a common but often undiagnosed or misdiagnosed condition. Patch testing aids in its confirmation and identification of the offending allergen. This study aimed to find the frequency of positive patch test reactions in cases with suspected allergic contact dermatitis (ACD) to footwear, as well as the common responsible allergens. This is a retrospective record based study of 37 patients, with suspected ACD to footwear, who underwent patch testing with Indian standard series and Indian footwear series from July 2012 to July 2015. The majority of patients (45.94%) belonged to the age group of 20-40 years. Dorsal aspects of feet (81.08%) and soles (18.92%) were the common sites involved. Patch test was positive in 18.92% patients. The most common causative allergens were hydroquinone monobenzylether (8.11%) and 4-aminoazobenzene (5.41%). Common chemicals implicated in ACD were rubber, rubber additives, and dyes. The principal culprit allergens were hydroquinone monobenzylether and 4-aminoazobenzene.

  15. Common Allergens Identified Based on Patch Test Results in Patients with Suspected Contact Dermatitis of the Scalp

    PubMed Central

    Aleid, Nouf M.; Fertig, Raymond; Maddy, Austin; Tosti, Antonella

    2017-01-01

    Background Contact dermatitis of the scalp is common and might be caused by many chemicals including metals, ingredients of shampoos and conditioners, dyes, or other hair treatments. Eliciting a careful history and patch tests are necessary to identify the responsible allergen and prevent relapses. Objectives To identify allergens that may cause contact dermatitis of the scalp by reviewing patch test results. Methods We reviewed the records of 1,015 patients referred for patch testing at the Dermatology Department of the University of Miami. A total of 226 patients (205 females and 21 males) with suspected scalp contact dermatitis were identified, and the patch test results and clinical data for those patients were analyzed. Most patients were referred for patch testing from a specialized hair clinic at our institution. Results The most common allergens in our study population were nickel (23.8%), cobalt (21.0%), balsam of Peru (18.2%), fragrance mix (14.4%), carba mix (11.6%), and propylene glycol (PG) (8.8%). The majority of patients were females aged 40–59 years, and scalp itching or burning were reported as the most common symptom. Conclusion Frequent sources of allergens for metals include hair clasps, pins, and brushes, while frequent sources of allergens for preservatives, fragrance mix, and balsam of Peru include shampoos, conditioners, and hair gels. Frequent sources of allergens for PG include topical medications. PMID:28611994

  16. Patch testing and cross sensitivity study of adverse cutaneous drug reactions due to anticonvulsants: A preliminary report.

    PubMed

    Shiny, T N; Mahajan, Vikram K; Mehta, Karaninder S; Chauhan, Pushpinder S; Rawat, Ritu; Sharma, Rajni

    2017-03-26

    To evaluate the utility of patch test and cross-sensitivity patterns in patients with adverse cutaneous drug reactions (ACDR) from common anticonvulsants. Twenty-four (M:F = 13:11) patients aged 18-75 years with ACDR from anticonvulsants were patch tested 3-27 mo after complete recovery using carbamazepine, phenytoin, phenobarbitone, lamotrigine, and sodium valproate in 10%, 20% and 30% conc. in pet. after informed consent. Positive reactions persisting on D3 and D4 were considered significant. Clinical patterns were exanthematous drug rash with or without systemic involvement (DRESS) in 18 (75%), Stevens-Johnsons syndrome/toxic epidermal necrolysis (SJS/TEN) overlap and TEN in 2 (8.3%) patients each, SJS and lichenoid drug eruption in 1 (4.2%) patient each, respectively. The implicated drugs were phenytoin in 14 (58.3%), carbamazepine in 9 (37.5%), phenobarbitone in 2 (8.3%), and lamotrigine in 1 (4.7%) patients, respectively. Twelve (50%) patients elicited positive reactions to implicated drugs; carbamazepine in 6 (50%), phenytoin alone in 4 (33.3%), phenobarbitone alone in 1 (8.3%), and both phenytoin and phenobarbitone in 1 (8.33%) patients, respectively. Cross-reactions occurred in 11 (92%) patients. Six patients with carbamazepine positive patch test reaction showed cross sensitivity with phenobarbitone, sodium valproate and/or lamotrigine. Three (75%) patients among positive phenytoin patch test reactions had cross reactions with phenobarbitone, lamotrigine, and/or valproate. Carbamazepine remains the commonest anticonvulsant causing ACDRs and cross-reactions with other anticonvulsants are possible. Drug patch testing appears useful in DRESS for drug imputability and cross-reactions established clinically.

  17. Randomized, double-blind, placebo-controlled trial using lidocaine patch 5% in traumatic rib fractures.

    PubMed

    Ingalls, Nichole K; Horton, Zachary A; Bettendorf, Matthew; Frye, Ira; Rodriguez, Carlos

    2010-02-01

    The lidocaine patch 5% was developed to treat postherpetic neuralgia. Anecdotal experience at our institution suggests the lidocaine patch 5% decreases narcotic usage in patients with traumatic rib fractures. This trial was developed to define the patch's efficacy. Patients with rib fractures admitted to the trauma service at our Level I trauma center were enrolled and randomized in a 1 to 1 double-blind manner to receive a lidocaine patch 5% or placebo patch. Fifty-eight patients who met the inclusion criteria were enrolled from January 2007 to August 2008. Demographic and clinical information were recorded. The primary outcomes variable was total narcotic use, analyzed using the 1-tailed Mann-Whitney test. The secondary outcomes variables included non-narcotic pain medication, average pain score, pulmonary complications, and length of stay. Significance was defined based on a 1-sided test for the primary outcome and 2-sided tests for other comparisons, at p < 0.05. Thirty-three patients received the lidocaine patch 5% and 25 received the placebo patch. There were no significant differences in age, number of rib fractures, gender, trauma mechanism, preinjury lung disease, smoking history, percent of current smokers, and need for placement of chest tube between the lidocaine patch 5% and placebo groups. There was no difference between the lidocaine patch 5% and placebo groups, respectively, with regard to total IV narcotic usage: median, 0.23 units versus 0.26 units; total oral narcotics: median, 4 units versus 7 units; pain score: 5.6 +/- 0.4 versus 6.0 +/- 0.3 (mean +/- SEM); length of stay: 7.8 +/- 1.1 versus 6.2 +/- 0.7; or percentage of patients with pulmonary complications: 72.7% versus 72.0%. The lidocaine patch 5% does not significantly improve pain control in polytrauma patients with traumatic rib fractures.

  18. Additive value of patch testing custom epoxy materials from the workplace at the occupational disease specialty clinic in Toronto.

    PubMed

    Houle, Marie-Claude; Holness, D Linn; Dekoven, Joel; Skotnicki, Sandy

    2012-01-01

    Allergic contact dermatitis (ACD) to epoxy resins is one of the major causes of occupationally induced ACD. Testing of custom epoxy materials from the workplace is often performed to diagnose ACD. The objective of this study was to investigate the additive value of patch testing custom-made epoxy materials. We retrospectively analyzed outcomes of 24 patients who were tested to custom epoxy resin materials between January 2002 and July 2011. For 11 patients (46%), the testing of their materials from work had no additional value (negative results). For 13 patients (54%), there was an additional value of testing custom allergens. Of those, 7 patients (54%) had positive reactions to custom epoxy materials that reinforced the test results found with the commercially available allergens, and 6 (46%) patients had positive reactions only to custom epoxy materials. Therefore, for 6 patients (25%), there was a definite additive value of testing custom epoxy materials because the allergy was discovered with custom testing and not with the commercially available allergens. Because of the high percentage (54%) of patients with additive value of patch testing custom epoxy materials, we think that the inclusion of actual workplace epoxy materials should be strongly considered when patch testing patients with occupational epoxy exposure.

  19. Patch testing and cross sensitivity study of adverse cutaneous drug reactions due to anticonvulsants: A preliminary report

    PubMed Central

    Shiny, T N; Mahajan, Vikram K; Mehta, Karaninder S; Chauhan, Pushpinder S; Rawat, Ritu; Sharma, Rajni

    2017-01-01

    AIM To evaluate the utility of patch test and cross-sensitivity patterns in patients with adverse cutaneous drug reactions (ACDR) from common anticonvulsants. METHODS Twenty-four (M:F = 13:11) patients aged 18-75 years with ACDR from anticonvulsants were patch tested 3-27 mo after complete recovery using carbamazepine, phenytoin, phenobarbitone, lamotrigine, and sodium valproate in 10%, 20% and 30% conc. in pet. after informed consent. Positive reactions persisting on D3 and D4 were considered significant. RESULTS Clinical patterns were exanthematous drug rash with or without systemic involvement (DRESS) in 18 (75%), Stevens-Johnsons syndrome/toxic epidermal necrolysis (SJS/TEN) overlap and TEN in 2 (8.3%) patients each, SJS and lichenoid drug eruption in 1 (4.2%) patient each, respectively. The implicated drugs were phenytoin in 14 (58.3%), carbamazepine in 9 (37.5%), phenobarbitone in 2 (8.3%), and lamotrigine in 1 (4.7%) patients, respectively. Twelve (50%) patients elicited positive reactions to implicated drugs; carbamazepine in 6 (50%), phenytoin alone in 4 (33.3%), phenobarbitone alone in 1 (8.3%), and both phenytoin and phenobarbitone in 1 (8.33%) patients, respectively. Cross-reactions occurred in 11 (92%) patients. Six patients with carbamazepine positive patch test reaction showed cross sensitivity with phenobarbitone, sodium valproate and/or lamotrigine. Three (75%) patients among positive phenytoin patch test reactions had cross reactions with phenobarbitone, lamotrigine, and/or valproate. CONCLUSION Carbamazepine remains the commonest anticonvulsant causing ACDRs and cross-reactions with other anticonvulsants are possible. Drug patch testing appears useful in DRESS for drug imputability and cross-reactions established clinically. PMID:28396847

  20. 2-Amino-4-hydroxyethylaminoanisole sulfate - a coupler causing contact allergy from use in hair dyes.

    PubMed

    Madsen, Jakob T; Andersen, Klaus E

    2016-02-01

    Allergic contact dermatitis resulting from the use of permanent hair dyes is common. Approximately 100 hair dye chemicals are permitted in Europe. Hair dye ingredients may change over time, and hence new hair dye allergens should be looked for continuously. To review positive patch test reactions to the coupler 2-amino-4-hydroxyethylaminoanisole sulfate 2% pet. from 2005 to 2014. Patch test results from the Allergen Bank database for eczema patients patch tested with 2-amino-4-hydroxyethylaminoanisole sulfate 2% pet. from 2005 to 2014 were reviewed. A total of 902 dermatitis patients (154 from the dermatology department and 748 from 65 practices) were patch tested with amino-4-hydroxyethylaminoanisole sulfate 2% pet. from 2005 to 2014. Thirteen (1.4%) patients had a positive patch test reaction. Our results do not indicate irritant reactions. 2-Amino-4-hydroxyethylaminoanisole sulfate is a new but rare contact allergen. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Is the European standard series suitable for patch testing in Riyadh, Saudi Arabia?

    PubMed

    el-Rab, M O; al-Sheikh, O A

    1995-11-01

    Due to the lack of a regional patch test series in our geographical area, the suitability of the European standard series was evaluated by patch testing dermatitis patients in Riyadh, Saudi Arabia. Of 240 consecutive patients with various forms of dermatitis, 136 (57%) showed 1 or more positive patch tests, women, 74 (54%), slightly outnumbering men, 62 (46%). Positive reactions were found to 21 of the 22 items in the test series. Sensitization was most common to nickel sulfate (51 = 37.5%), potassium dichromate (48 = 35%) and cobalt chloride (43 = 32%) The frequency of sensitization to nickel was higher in women (41 = 30%) while that to dichromate was higher in men (39 = 29%). Less reactions were found to fragrance mix (21 = 15%), formaldehyde (15 = 11%) and neomycin sulfate (15 = 11%). Sensitization to other allergens ranged between 10 and 1%. Less than 1% of patients (0.7%) reacted to benzocaine and none to primin. The frequency of occurrence of multiple sensitivities is also presented. We conclude that the European standard series is suitable for patch testing dermatitis patients in our region, with the exception of benzocaine and primin. The addition of 3 allergens that could be of local relevance is discussed.

  2. Contact allergy to oxidized geraniol among Swedish dermatitis patients-A multicentre study by the Swedish Contact Dermatitis Research Group.

    PubMed

    Hagvall, Lina; Bruze, Magnus; Engfeldt, Malin; Isaksson, Marléne; Lindberg, Magnus; Ryberg, Kristina; Stenberg, Berndt; Svedman, Cecilia; Karlberg, Ann-Therese; Bråred Christensson, Johanna

    2018-06-21

    Geraniol is a widely used fragrance terpene, and is included in fragrance mix I. Geraniol is prone to autoxidation, forming the skin sensitizers geranial, neral, and geraniol-7-hydroperoxide. Oxidized geraniol has previously been patch tested in 1 clinic, giving 1% to 4.6% positive reactions in consecutive patients when tested at 2% to 11%. To compare test reactions to pure and oxidized geraniol, to compare 2 different test concentrations of oxidized geraniol and to investigate the pattern of concomitant reactions to fragrance markers of the baseline series in a multicentre setting. One thousand four hundred and seventy-six consecutive patients referred for patch testing were patch tested with geraniol 6% pet. and oxidized geraniol 6% and 11% pet. Pure geraniol 6% pet., oxidized geraniol 6% pet. and oxidized geraniol 11% pet. gave 1%, 3% and 8% positive patch test reactions and 0.7%, 3% and 5% doubtful reactions, respectively. Approximately 50% of the patients with doubtful reactions to oxidized geraniol 6% pet. had positive reactions to oxidized geraniol 11% pet. Oxidized geraniol 11% pet. provides better detection than oxidized geraniol 6% pet. As most patients reacted only to oxidized geraniol, it is important to explore further whether oxidized geraniol should be included in a baseline patch test series. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Polyethylene glycol as marker for nitrofurazone allergy: 20 years of experience from Turkey.

    PubMed

    Özkaya, Esen; Kılıç, Sıla

    2018-03-01

    Polyethylene glycols (PEGs) and propylene glycol (PG) are used as vehicles in various medicinal and cosmetic products. They are potential contact sensitizers, including low molecular weight PEGs in nitrofurazone preparations that are still widely used in Turkey. To investigate the prevalence of allergic contact dermatitis caused by PEG and PG in a relatively large group of patients in Turkey. In this retrospective, cross-sectional, single-centre study, 836 patients patch tested with PEG and PG between 1996 and 2015 were reviewed. Thirty-five patients (4.2%) showed positive patch test reactions to PEG, and 7 (0.8%) showed positive patch test reactions to PG, partly as late positive reactions with PEG. PEG sensitivity was almost exclusively related to nitrofurazone allergy. Patch test reactions to PG were currently relevant mainly with regard to the use of minoxidil, and antiherpetic or corticosteroid creams. Ten patients (25%) had concomitant contact allergies to various topical drugs containing mainly PEGs. PEG sensitivity seems to be a marker for contact allergy to topical nitrofurazone in Turkey. Nitrofurazone allergy appears to favour concomitant sensitization to PEG. We would suggest the inclusion of PEG in an extended baseline patch test series in Turkey. Late patch test readings are important to diagnose delayed positive reactions to PEG. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Patch test reactions to mite antigens: a GERDA multicentre study. Groupe d'Etudes et de Recherches en Dermato-Allergie.

    PubMed

    Castelain, M; Birnbaum, J; Castelain, P Y; Ducombs, G; Grosshans, E; Jelen, G; Lacroix, M; Meynadier, J; Mougeolle, J M; Lachapelle, J M

    1993-11-01

    We performed patch tests with Dermatophagoides pteronyssinus (Dp) antigens from 2 different sources in 355 non-randomly selected patients with atopic dermatitis (AD) and 398 subjects of a control group. The study demonstrated that contact sensitization to mites occurred in an appreciable % of AD cases (20.8%), using commonly available assay products. The differences recorded between the 2 materials tested were related to the concentration of P1 antigen. Non-atopic patients rarely showed positive reactions to Dp (0.75%), when strict criteria for readings were applied and if 2 readings were performed. Patients with positive patch tests did not necessarily show positive immediate skin tests. It would be useful to carry out tests systematically in atopic patients, even if it is not yet known what modern treatment would be best for the patient. Laboratories still do not provide standardized house dust mite preparations--measuring and codifying their biological activity--for use in patch tests. It is to be hoped that the extension of this type of test will lead to the production of better test materials, in syringes with homogeneous dispersion and concentration.

  5. The reactivity of the back revisited. Are there differences in reactivity in different parts of the back?

    PubMed

    Björk, Ann-Kristin; Bruze, Magnus; Engfeldt, Malin; Nielsen, Christel; Svedman, Cecilia

    2017-01-01

    In the contact dermatitis literature, it is regularly stated that the patch test reactivity on various areas of the back differs, which might have a large impact on the reproducibility of patch testing. To investigate the reproducibility of patch testing on the upper back with regard to the left as opposed to the right side, and the medial as opposed to the lateral part of the upper back. The reproducibility over time and with regard to the reactivity pattern was also investigated. Thirty-one subjects with contact allergy to the metals gold (n = 19) or nickel (n = 12) were patch tested with serial dilutions, in triplicate applications, on different locations on the upper back. The Friedman test was used for statistical calculations. No significant differences in the reactivity of the back were found. In all gold-allergic patients and 11 of 12 nickel-allergic patients, the allergy could be reproduced with regard to previous patch testing, but the degree of reactivity differed. When a high level of standardization of the patch test technique with the same test system was used, there were no differences in patch test reactions and sites of application on the upper back. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Lyral has been included in the patch test standard series in Germany.

    PubMed

    Geier, Johannes; Brasch, Jochen; Schnuch, Axel; Lessmann, Holger; Pirker, Claudia; Frosch, Peter J

    2002-05-01

    Lyral 5% pet. was tested in 3245 consecutive patch test patients in 20 departments of dermatology in order (i) to check the diagnostic quality of this patch test preparation, (ii) to examine concomitant reactions to Lyral and fragrance mix (FM), and (iii) to assess the frequency of contact allergy to Lyral in an unselected patch test population of German dermatological clinics. 62 patients reacted to Lyral, i.e. 1.9%. One third of the positive reactions were + + and + + +. The reaction index was 0.27. Thus, the test preparation can be regarded a good diagnostic tool. Lyral and fragrance mix (FM) were tested in parallel in 3185 patients. Of these, 300 (9.4%) reacted to FM, and 59 (1.9%) to Lyral. In 40 patients, positive reactions to both occurred, which is 13.3% of those reacting to FM, and 67.8% of those reacting to Lyral. So the concordance of positive test reactions to Lyral and FM was only slight. Based on these results, the German Contact Dermatitis Research Group (DKG) decided to add Lyral 5% pet. to the standard series.

  7. Comparing reliabilities of strip and conventional patch testing.

    PubMed

    Dickel, Heinrich; Geier, Johannes; Kreft, Burkhard; Pfützner, Wolfgang; Kuss, Oliver

    2017-06-01

    The standardized protocol for performing the strip patch test has proven to be valid, but evidence on its reliability is still missing. To estimate the parallel-test reliability of the strip patch test as compared with the conventional patch test. In this multicentre, prospective, randomized, investigator-blinded reliability study, 132 subjects were enrolled. Simultaneous duplicate strip and conventional patch tests were performed with the Finn Chambers ® on Scanpor ® tape test system and the patch test preparations nickel sulfate 5% pet., potassium dichromate 0.5% pet., and lanolin alcohol 30% pet. Reliability was estimated by the use of Cohen's kappa coefficient. Parallel-test reliability values of the three standard patch test preparations turned out to be acceptable, with slight advantages for the strip patch test. The differences in reliability were 9% (95%CI: -8% to 26%) for nickel sulfate and 23% (95%CI: -16% to 63%) for potassium dichromate, both favouring the strip patch test. The standardized strip patch test method for the detection of allergic contact sensitization in patients with suspected allergic contact dermatitis is reliable. Its application in routine clinical practice can be recommended, especially if the conventional patch test result is presumably false negative. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Severe allergic reactions to para-phenylenediamine in children and adolescents: should the patch test concentration of PPD be changed?

    PubMed

    Spornraft-Ragaller, Petra; Kämmerer, Eva; Gillitzer, Claus; Schmitt, Jochen

    2012-04-01

    Semipermanent henna tattoos containing para-phenylenediamine (PPD) are a well-known cause of severe contact dermatitis, mainly in children. Another relevant exposure source to PPD are hair dyes, which are increasingly used by children and have also been reported to cause intense facial and scalp dermatitis. German patch test guidelines for children recommend that PPD should only be tested in patients who have had a henna tattoo, and then at a reduced concentration of PPD 0.5 % for 24 hours. We report on patch test results in four patients, three children and one adolescent, with a history of contact dermatitis to henna tattoos or hair dye. We used the recommended or even lower patch test concentrations of PPD with 24-hours exposure in all patients. All patients showed very strong patch test reactions to PPD and cross-reactions to related compounds even after dilution of PPD to as low as 0.05 %. Therefore, we suggest that in children with a history of allergic reactions to this compound, a titration test should be performed beginning at a concentration of maximal 0.05 %. This procedure has also been proposed previously based on a larger cases series in adults. © The Authors • Journal compilation © Blackwell Verlag GmbH, Berlin.

  9. Recommendation to test limonene hydroperoxides 0·3% and linalool hydroperoxides 1·0% in the British baseline patch test series.

    PubMed

    Wlodek, C; Penfold, C M; Bourke, J F; Chowdhury, M M U; Cooper, S M; Ghaffar, S; Green, C; Holden, C R; Johnston, G A; Mughal, A A; Reckling, C; Sabroe, R A; Stone, N M; Thompson, D; Wilkinson, S M; Buckley, D A

    2017-12-01

    There is a significant rate of sensitization worldwide to the oxidized fragrance terpenes limonene and linalool. Patch testing to oxidized terpenes is not routinely carried out; the ideal patch test concentration is unknown. To determine the best test concentrations for limonene and linalool hydroperoxides, added to the British baseline patch test series, to optimize detection of true allergy and to minimize irritant reactions. During 2013-2014, 4563 consecutive patients in 12 U.K. centres were tested to hydroperoxides of limonene in petrolatum (pet.) 0·3%, 0·2% and 0·1%, and hydroperoxides of linalool 1·0%, 0·5% and 0·25% pet. Irritant reactions were recorded separately from doubtful reactions. Concomitant reactions to other fragrance markers and clinical relevance were documented. Limonene hydroperoxide 0·3% gave positive reactions in 241 (5·3%) patients, irritant reactions in 93 (2·0%) and doubtful reactions in 110 (2·4%). Linalool hydroperoxide 1·0% gave positive reactions in 352 (7·7%), irritant reactions in 178 (3·9%) and doubtful reactions in 132 (2·9%). A total of 119 patients with crescendo reactions to 0·3% limonene would have been missed if only tested with 0·1% and 131 patients with crescendo reactions to 1·0% linalool would have been missed if only tested with 0·25%. In almost two-thirds of patients with positive patch tests to limonene and linalool the reaction was clinically relevant. The majority of patients did not react to any fragrance marker in the baseline series. We recommend that limonene hydroperoxides be tested at 0·3% and linalool hydroperoxides at 1·0% in the British baseline patch test series. © 2017 British Association of Dermatologists.

  10. Contact Dermatitis to Personal Sporting Equipment in Youth.

    PubMed

    Marzario, Barbara; Burrows, Dianne; Skotnicki, Sandy

    2016-07-01

    Contact dermatitis to personal sporting equipment in youth is poorly studied. To review the results of patch testing 6 youth to their sporting equipment in a dermatology general private practice from 2006 to 2011. A retrospective analysis of 6 youth aged 11 to 14 who were evaluated for chronic and persistent dermatitis occurring in relation to sports equipment was conducted. All patients were subjected to epicutaneous (patch) testing, which included some or all of the following: North American Contact Dermatitis Group (NACGD) series, textile series, rubber series, corticosteroid series, and raw material from the patients' own personal equipment. All cases had 1 or more positive patch test reactions to an allergen within the aforementioned series, and 3 subjects tested positive to their personal equipment in raw form. Allergic contact dermatitis, not irritant, was deemed the relevant cause of chronic dermatitis in 4 of the 6 patients due to positive reactions to epicutaneous tests and/or personal equipment. The utility of testing to patients' own sporting equipment was shown to be of additional value and should be considered when patch testing for contact allergy to sporting equipment. © The Author(s) 2015.

  11. Response to rivastigmine transdermal patch or memantine plus rivastigmine patch is affected by apolipoprotein E genotype in Alzheimer patients.

    PubMed

    Han, Hyun Jeong; Kim, Byeong C; Lee, Jun-Young; Ryu, Seung-Ho; Na, Hae Ri; Yoon, Soo Jin; Park, Hyun Young; Shin, Joon Hyun; Cho, Soo-Jin; Yi, Hyon-Ah; Choi, Mun Seong; Heo, Jae-Hyeok; Park, Kyung Won; Kim, Kwang K; Choi, Seong Hye

    2012-01-01

    The apolipoprotein E (APOE) genotype in response to pharmacological treatments in patients with Alzheimer's disease (AD) remains a matter of controversy. This analysis investigated the effect of the APOE genotype on the clinical response to rivastigmine transdermal patch monotherapy or memantine plus rivastigmine patch in patients with mild to moderate AD. Two hundred and six (n = 206) patients with probable AD and Mini-Mental State Examination (MMSE) scores of 10-20 were randomized to rivastigmine patch monotherapy or memantine plus rivastigmine patch for 24 weeks. Of the 206 patients with probable AD, 146 patients who consented to genetic testing for APOE were included and assessed for this subgroup study. There were no significant differences on MMSE, NPI, ADAS-cog, ADCS-ADL, CDR-SB, NPI and FAB between rivastigmine patch monotherapy and memantine plus rivastigmine patch according to the APOE genotype. However, patients with moderately severe AD (MMSE ≤15) who were APOE ε4 carriers showed higher responder rates on ADCS-ADL with memantine plus rivastigmine patch compared to rivastigmine patch monotherapy. Moderately severe AD patients with the APOE ε4 allele may respond more favorably to memantine plus rivastigmine patch than ε4 noncarriers. Copyright © 2012 S. Karger AG, Basel.

  12. Patch testing in non-immediate cutaneous adverse drug reactions: value of extemporaneous patch tests.

    PubMed

    Assier, Haudrey; Valeyrie-Allanore, Laurence; Gener, Gwendeline; Verlinde Carvalh, Muriel; Chosidow, Olivier; Wolkenstein, Pierre

    2017-11-01

    Patch testing following a standardized protocol is reliable for identifying the culprit drug in cutaneous adverse drug reactions (CADRs). However, these patch tests (PTs) require pharmaceutical material and staff, which are not always easily available. To evaluate an extemporaneous PT method in CADRs. We retrospectively analysed data for all patients referred to our department between March 2009 and June 2013 for patch testing after a non-immediate CADR. The patients who supplied their own suspected drugs were tested both with extemporaneous PTs and with conventional PTs. Extemporaneous PTs involved a nurse crushing and diluting the drug in pet. in a ratio of approximately one-third to two-thirds. Standardized PTs were performed according to guidelines, with commercial drugs diluted to 30% or with active ingredients diluted to 10%. We analysed the data for the two PT methods in terms of the number of positive test reactions, drugs tested, and type of CADR for patients in whom the two PT methods were used. In total, 75 of 156 patients underwent the two PT procedures, including 91 double tests. Overall, 21 tests gave positive reactions with the two methods, and 69 other tests gave negative results with the two methods. Our series yielded results similar to those of published series concerning the types of CADR and the drugs responsible. Our results suggest that, for CADRs, if a patient supplies a suspected drug but if the pharmaceutical material and staff are not available for conventional PTs, extemporaneous PTs performed by the nurse with the commercial drug used by the patient can be useful and reliable. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Contact urticaria, allergic contact dermatitis, and photoallergic contact dermatitis from oxybenzone.

    PubMed

    Landers, Maeran; Law, Sandra; Storrs, Frances J

    2003-03-01

    There is little literature regarding conventional patch tests and photopatch tests to oxybenzone resulting in both immediate- and delayed-type hypersensitivity reactions. A patient was patch-tested and photopatch-tested to various sunscreen chemicals. Both immediate- and delayed-type hypersensitivity reactions were observed with oxybenzone. The positive patch tests were also photoaccentuated. Oxybenzone, a common sunscreen allergen, can result in both contact urticaria and delayed-type hypersensitivity on both conventional patch testing and photopatch testing. Allergic contact dermatitis to sunscreen chemicals has traditionally included contact urticaria, allergic contact dermatitis, and photoallergic contact dermatitis. Due to the recognition of p-aminobenzoic acid (PABA) and its esters as sensitizers, the presence of benzophenones in "PABA-free" sunscreens has become more prevalent, especially in sunscreens with a sun protection factor (SPF) greater than 8. In our patient, immediate- and delayed-type hypersensitivity reactions were seen to oxybenzone (2-hydroxy-4-methoxybenzophenone, 2-benzoyl-5-methoxyphenol, benzophenone-3, Eusolex 4360, Escalol 567, EUSORB 228, Spectra-Sorb UV-9, Uvinul M-40) upon conventional patch testing and photopatch testing.

  14. Contact allergy to corticosteroids and Malassezia furfur in seborrhoeic dermatitis patients.

    PubMed

    Ljubojevic, S; Lipozencic, J; Basta-Juzbasic, A

    2011-06-01

    Seborrhoeic dermatitis (SD) is a chronic skin disease, requiring long-term treatment, which might promote sensitization. Malassezia furfur (Mf) plays an important role in seborrhoeic dermatitis. Objectives  The aim of this study was to determine the frequency of contact sensitivity in SD patients. A total of 100 patients and 20 healthy controls (HC) were investigated: 50 suffering from SD with no previous local corticosteroid treatment (SDN), 50 SD patients treated with local corticosteroids (SDC). Mycological examination for Mf was performed. All patients were patch tested with the baseline standard, corticosteroid series, with 12 commercial corticosteroid preparations frequently used in Croatia; and also with Mf. Malassezia furfur was found in 44 (88%) SDN, 37 (74%) SDC, and in 4 (20%) HC; patch test reaction to Mf was positive in one SDN and in three SDC. Positive patch tests to standard allergens were observed in 17 (34%) SDN, 33 (66%) SDC and 2 (10%) HC. Patch tests to the corticosteroid series revealed positive reactions in 4 SDC and to commercial corticosteroids in seven patients, i.e. 2 SD and 5 SDC. Patch tests to the baseline series and to both individual corticosteroid and commercial corticosteroid preparations should be performed in SD patients with persistent dermatitis, as contact-allergic reactions may complicate their dermatitis. Sensitization to Mf was found to be infrequent. © 2010 The Authors. Journal of the European Academy of Dermatology and Venereology © 2010 European Academy of Dermatology and Venereology.

  15. Pattern of occupational allergic dermatitis in the Dermatology Clinic, Hospital Kuala Lumpur.

    PubMed

    Rohna, R; Ganesapillai, T; Salbiah, D; Zaiton, I

    1999-03-01

    A two years retrospective analysis of patients diagnosed as contact allergic dermatitis with positive patch test attending the Dermatology clinic was performed. Of the 346 patients with a positive patch test, 14% had occupational dermatitis. This condition affected mainly young and inexperienced workers. An inverse relationship was seen between age and prevalence of occupational allergic dermatitis. Allergic hand dermatitis was the commonest presentation in occupational allergic dermatitis. This was followed by dermatitis of the exposed skin (face, neck, hands and forearms). The common sensitising agents identified were rubber chemicals and nickel. The two main groups at risk were factory workers and medical personnel. The common allergens found in factory workers were epoxy resin, pewter, nickel and rubber chemicals. Exposure dermatitis occurred in patients working in the pewter industry. Two thirds of medical personnel with hand dermatitis were allergic to rubber gloves. One year follow up after patch testing showed that 19% of patients still suffered from chronic dermatitis. Dermatitis improved in 34% of patients. Forty-seven percent were cured and stopped attending the clinic after patch testing and adequate counselling.

  16. Toothpaste allergy as a cause of cheilitis in Israeli patients.

    PubMed

    Lavy, Yaron; Slodownik, Dan; Trattner, Akiva; Ingber, Arieh

    2009-01-01

    Allergic contact cheilitis may appear after exposure to different substances, including dental materials, toothpastes, cosmetics, foods and medications. To compare the rate of toothpaste allergy between patients with and without cheilitis and to examine the yield of our proposed toothpaste patch test kit for use in patients with cheilitis. A patch test kit containing 11 substances used in toothpastes was formed. The study sample consisted of 44 patients, 24 with cheilitis (study group) and 20 with contact dermatitis but without cheilitis (control group). Eleven patients in the study group (45%) were found to be allergic to toothpaste, compared to only one patient (5%) in the control group (p < .05). The rate of toothpaste allergy among patients with cheilitis might be higher than previously reported. Patch-testing with our toothpaste series is recommended in the evaluation of cheilitis.

  17. Allergic contact dermatitis to benzocaine: the importance of concomitant positive patch test results.

    PubMed

    González-Rodríguez, A J; Gutiérrez-Paredes, E M; Revert Fernández, Á; Jordá-Cuevas, E

    2013-03-01

    Local anesthetics are widely used in clinical practice, and adverse effects are not uncommon. Delayed hypersensitivity reactions are among the most common effects, but immediate-type reactions may also occur. Patch testing should be considered in patients with hypersensitivity reactions. We present a case of allergic contact dermatitis to benzocaine that was detected incidentally by patch testing and highlight the importance of correctly interpreting patch test results when there are concomitant positive reactions. Copyright © 2011 Elsevier España, S.L. and AEDV. All rights reserved.

  18. Patch tests with fragrance materials and preservatives.

    PubMed

    de Groot, A C; Liem, D H; Nater, J P; van Ketel, W G

    1985-02-01

    179 patients suspected of cosmetic allergy were patch tested with a series of 16 fragrance materials and 9 preservatives. In 67 patients (37.4%), 1 or more of these substances gave positive reactions. In the group of fragrance materials, the largest numbers of positive patch test reactions were seen to isoeugenol, oak moss, geraniol, alpha-amylcinnamic alcohol, and a mixture of alpha-amylcinnamic aldehyde and alpha-hexylcinnamic aldehyde. The fragrance mix in the ICDRG standard series detected nearly 80% of cases of contact allergy to fragrance materials other than its constituents. In the group of preservatives, Kathon CG and quaternium-15 scored the highest number of positive reactions. It is argued that the commonly used patch test concentrations of 2% for oak moss and geraniol may be too low to detect all cases of sensitization.

  19. Patch-test reactions to plastic and glue allergens.

    PubMed

    Kanerva, L; Jolanki, R; Alanko, K; Estlander, T

    1999-07-01

    Plastics and glues are common causes of occupational dermatoses, but only few reports have dealt with patch-test reactions caused by plastic and glue allergens. Patients exposed to plastics and remitted to an occupational dermatology clinic, were patch-tested with 50-53 plastic and glue allergens during a 6-year period. Conventional patch-test techniques were used. The most common causes of allergic patch-test reactions in 360 patients were novolac epoxy resin (5.1%), phenol formaldehyde resin (3.1%), 4-tert-butylcatechol (2.6%), phenyl glycidyl ether (2.6%), diaminodiphenyl methane (2.2%), benzoyl peroxide (2.2%), hexamethylene tetramine (2.0%) and o-cresyl glycidyl ether (1.6%). The allergens that most often elicited irritant patch-test reactions were: benzoyl peroxide (9.5%), abitol alcohol (3.6%), hydroquinone (3.1%), acid-catalyzed phenol formaldehyde resin (2.5%) and toluene diisocyanate (1.9%). Twenty-six out of 53 chemicals caused no allergic reaction during the 6-year period. Plastic allergens in the standard series provoked allergic reactions with formaldehyde (5.8%), diglycidyl ether of bisphenol A (3.2%), 4-tert-butylphenol-formaldehyde-resin (1.1%), toluene sulphonamide formaldehyde-resin (1.1%) and triethylenglycol diacrylate (0.4%). Although half of the plastic chemicals gave no allergic patch-test reactions during a 6-year period, with unusual allergens this low yield needs to be accepted, because otherwise rare allergies will not be detected. Also a negative reaction has diagnostic value.

  20. Is a specific eyelid patch test series useful? Results of a French prospective study.

    PubMed

    Assier, Haudrey; Tetart, Florence; Avenel-Audran, Martine; Barbaud, Annick; Ferrier-le Bouëdec, Marie-Christine; Giordano-Labadie, Françoise; Milpied, Brigitte; Amsler, Emmanuelle; Collet, Evelyne; Girardin, Pascal; Soria, Angèle; Waton, Julie; Truchetet, François; Bourrain, Jean-Luc; Gener, Gwendeline; Bernier, Claire; Raison-Peyron, Nadia

    2018-06-08

    Eyelids are frequent sites of contact dermatitis. No prospective study focused on eyelid allergic contact dermatitis (EACD) has yet been published, and this topic has never been studied in French patients. To prospectively evaluate the usefulness of an eyelid series in French patients patch tested because of EACD, and to describe these patients. We prospectively analysed standardized data for all patients referred to our departments between September 2014 and August 2016 for patch testing for suspected EACD as the main reason. All patients were patch tested with an eyelid series, the European baseline series (EBS), the French additional series, and their personal products. Patch testing with additional series and repeated open application tests (ROATs) or open tests were performed if necessary. A standardized assessment of the relevance was used, and the analysis of the results was focused on patients having positive test results with a current certain relevance. Two-hundred and sixty-four patients (238 women and 26 men) were included. Three-hundred and twenty-two tests gave positive results in 167 patients, 84 of whom had currently relevant reactions: 56 had currently relevant positive test reactions to the EBS, 16 had currently relevant positive test reactions to their personal products, 8 had currently relevant positive test reactions to the French additional series, and 4 had currently relevant positive test reactions to the eyelid series. Sixty-seven per cent of all relevant cases were related to cosmetic products. The most frequent allergens with current relevance were methylisothiazolinone (10.2%), fragrance mix I (3%), nickel (2.7%), hydroxyperoxides of linalool (2.7%) and limonene (2.3%), and Myroxylon pereirae (2.3%). Current atopic dermatitis was found in 9.5% of patients. The duration of dermatitis was shorter (23.2 vs 34.2 months; P = .035) in patients with currently relevant test reactions. The percentage of currently relevant tests remained the same when atopic patients or dermatitis localized only on the eyelids were taken into account. In French patients, testing for EACD with the extended baseline series and personal products, also including ROATs and use tests, appears to be adequate, considering the currently relevant positive test reactions. The regular addition of an eyelid series does not seem to be necessary. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Limonene hydroperoxide analogues show specific patch test reactions.

    PubMed

    Christensson, Johanna Bråred; Hellsén, Staffan; Börje, Anna; Karlberg, Ann-Therese

    2014-05-01

    The fragrance terpene R-limonene is a very weak sensitizer, but forms allergenic oxidation products upon contact with air. The primary oxidation products of oxidized limonene, the hydroperoxides, have an important impact on the sensitizing potency of the oxidation mixture. One analogue, limonene-1-hydroperoxide, was experimentally shown to be a significantly more potent sensitizer than limonene-2-hydroperoxide in the local lymph node assay with non-pooled lymph nodes. To investigate the pattern of reactivity among consecutive dermatitis patients to two structurally closely related limonene hydroperoxides, limonene-1-hydroperoxide and limonene-2-hydroperoxide. Limonene-1-hydroperoxide, limonene-2-hydroperoxide, at 0.5% in petrolatum, and oxidized limonene 3.0% pet. were tested in 763 consecutive dermatitis patients. Of the tested materials, limonene-1-hydroperoxide gave most reactions, with 2.4% of the patients showing positive patch test reactions. Limonene-2-hydroperoxide and oxidized R-limonene gave 1.7% and 1.2% positive patch test reactions, respectively. Concomitant positive patch test reactions to other fragrance markers in the baseline series were frequently noted. The results are in accordance with the experimental studies, as limonene-1-hydroperoxide gave more positive patch test reactions in the tested patients than limonene-2-hydroperoxide. Furthermore, the results support the specificity of the allergenic activity of the limonene hydroperoxide analogues and the importance of oxidized limonene as a cause of contact allergy. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Fragrance patch tests prepared in advance may give false-negative reactions.

    PubMed

    Mowitz, Martin; Svedman, Cecilia; Zimerson, Erik; Bruze, Magnus

    2014-11-01

    Several of the ingredients in fragrance mix I (FM I) have been shown to evaporate from petrolatum preparations applied in test chambers to an extent that can be suspected to affect the patch test result. To compare the reactivity towards FM I and fragrance mix II (FM II) when they are applied in test chambers in advance and immediately prior to the patch test occasion. Seven hundred and ninety-five consecutive patients were simultaneously patch tested with duplicate samples of FM I and FM II. One sample was applied in the test chamber 6 days in advance (6D sample), and the other sample was applied immediately before the patients were patch tested (fresh sample). Twenty-two (2.8%) patients reacted exclusively to the fresh sample of FM I, 6 (0.7%) reacted exclusively to the 6D sample, and 22 (2.8%) reacted to both samples. The corresponding numbers for FM II were 9 (1.1%) for the fresh sample, 6 (0.7%) for the 6D sample and 12 (1.5%) for both samples. There was a statistically significant difference between the numbers of patients reacting to the fresh and 6D samples of FM I. No corresponding difference was observed for FM II. This can probably be explained by differences in volatilities between the ingredients of FM I and FM II. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Recommendation to increase the test concentration of methylchloroisothiazolinone/methylisothiazolinone in the European baseline patch test series - on behalf of the European Society of Contact Dermatitis and the European Environmental and Contact Dermatitis Research Group.

    PubMed

    Bruze, Magnus; Goossens, An; Isaksson, Marléne

    2014-07-01

    Methylchloroisothiazolinone (MCI)/methylisothiazolinone (MI) in aqua is present in the European baseline patch test series at 100 ppm, whereas 200 ppm has been used in Sweden since 1986, in Spain in the late 1980s, and, in recent years, also in the United Kingdom and Ireland. With regard to MCI/MI, to investigate the data on contact allergy rates in dermatitis patients, the frequencies of allergic contact dermatitis in the same group, and adverse reactions, particularly patch test sensitization in tested dermatitis patients, and to find the optimal patch test concentration as dose in mg/cm(2) . We performed a survey of the literature found via the National Library of Medicine (PubMed, http://www.ncbi.nlm.nih.gov/pubmed, last accessed 20 February 2014). MCI/MI at 200 ppm aq. diagnosis substantially more contact allergy and allergic contact dermatitis, without any registered increase in patch test sensitization, than the presently used concentration of 100 ppm. MCI/MI at 200 ppm aq. is recommended to be included in the European baseline patch test series. To avoid patch test sensitization, a dose of 0.006 mg/cm(2) must not be exceeded, which means a volume of 15 µl for Finn Chambers(®) (Ø 8 mm). © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. The utility of patch tests using larger screening series of allergens.

    PubMed

    Larkin, A; Rietschel, R L

    1998-09-01

    The number of patch test allergens available within the United States for routine commercial purchase is limited. Allergens chosen for inclusion in routine screening series or patch test trays vary, and the degree of information obtained from any series may or may not serve a patient's needs. Knowledge of how well the allergens chosen for inclusion in the two commercially available sources perform compared with a more expansive panel of tests can help physicians select the more appropriate tests. From 1994 to mid-1997, 554 patients were tested with allergens recommended by the North American Contact Dermatitis Group (NACDG). This included all allergens currently available from both current domestic sources, although not in the identical form used by the Thin-layer Rapid Use Epicutaneous Test (TRUE) test (Glaxo Dermatology, Research Triangle Park, NC). Another 185 patients were tested with supplemental series of allergens. The larger the series of allergens used, the more positive tests were found and the more relevant tests as well. Hermal patch test allergens identified about 55% of the information found by the NACDG series; the TRUE test allergens (but not in the TRUE test system) identified 65%. Of the 103 reactions to supplemental allergens not found by the NACDG series, 59 were relevant. Larger series of allergens can enhance accurate diagnosis of allergic contact dermatitis. No single arbitrary series of allergens can adequately survey the contemporary environment of individual patients. Selection of allergens for testing requires consideration of the patient's history and access to appropriate environmental contactants.

  5. Ethylhexylglycerin: a low-risk, but highly relevant, sensitizer in 'hypo-allergenic' cosmetics.

    PubMed

    Aerts, Olivier; Verhulst, Lien; Goossens, An

    2016-05-01

    Ethylhexylglycerin is a relatively new cosmetic ingredient that is used for its surfactant, emollient, skin-conditioning and antimicrobial properties. Since 2002, it has been occasionally reported as a contact allergen. To report on 13 patients who presented with allergic contact dermatitis caused by ethylhexylglycerin, evaluated at two Belgian university patch test clinics during the period 1990-2015. The patients were patch tested with the European baseline series, a cosmetic series, and - if indicated - additional series. Both the cosmetic products used and their single ingredients were patch tested. All but one of the ethylhexylglycerin-allergic patients were female, with a median age of 43 years (range: 29-81 years), most often suffering from dermatitis on the face, and sometimes on the hands and/or axillae. As the culprit products, leave-on cosmetics were identified, including a high number of proclaimed 'hypo-allergenic' and 'preservative-free' facial creams, sun protection creams, and deodorants. Ethylhexylglycerin is a rare, but highly relevant, cosmetic sensitizer, even in those products advertised to be safe for consumers. Targeted patch testing with ethylhexylglycerin 5% pet. is very useful, and routine patch testing in a cosmetic series may be considered. Higher test concentrations might be indicated in selected cases. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Pediatric Contact Dermatitis Registry Data on Contact Allergy in Children With Atopic Dermatitis.

    PubMed

    Jacob, Sharon E; McGowan, Maria; Silverberg, Nanette B; Pelletier, Janice L; Fonacier, Luz; Mousdicas, Nico; Powell, Doug; Scheman, Andrew; Goldenberg, Alina

    2017-08-01

    Atopic dermatitis (AD) and allergic contact dermatitis (ACD) have a dynamic relationship not yet fully understood. Investigation has been limited thus far by a paucity of data on the overlap of these disorders in pediatric patients. To use data from the Pediatric Contact Dermatitis Registry to elucidate the associations and sensitizations among patients with concomitant AD and ACD. This retrospective case review examined 1142 patch test cases of children younger than 18 years, who were registered between January 1, 2015, and December 31, 2015, by 84 health care providers (physicians, nurse practitioners, physician assistants) from across the United States. Data were gathered electronically from multidisciplinary providers within outpatient clinics throughout the United States on pediatric patients (ages 0-18 years). All participants were patch-tested to assess sensitizations to various allergens; history of AD was noted by the patch-testing providers. Primary outcomes were sensitization rates to various patch-tested allergens. A total of 1142 patients were evaluated: 189 boys (34.2%) and 363 girls (65.8%) in the AD group and 198 boys (36.1%) and 350 girls (63.9%) in the non-AD group (data on gender identification were missing for 17 patients). Compared with those without AD, patch-tested patients with AD were 1.3 years younger (10.5 vs 11.8 years; P < .001) and had longer history of dermatitis (3.5 vs 1.8 years; P < .001). Patch-tested patients designated as Asian or African American were more likely to have concurrent AD (odds ratio [OR], 1.92; 95% CI, 1.20-3.10; P = .008; and OR, 4.09; 95% CI, 2.70-6.20; P <.001, respectively). Patients with AD with generalized distribution were the most likely to be patch tested (OR, 4.68; 95% CI, 3.50-6.30; P < .001). Patients with AD had different reaction profiles than those without AD, with increased frequency of reactions to cocamidopropyl betaine, wool alcohol, lanolin, tixocortol pivalate, and parthenolide. Patients with AD were also noted to have lower frequency of reaction to methylisothiazolinone, cobalt, and potassium dichromate. Children with AD showed significant reaction patterns to allergens notable for their use in skin care preparations. This study adds to the current understanding of AD in ACD, and the continued need to investigate the interplay between these disease processes to optimize care for pediatric patients with these conditions.

  7. Pediatric Contact Dermatitis Registry Data on Contact Allergy in Children With Atopic Dermatitis

    PubMed Central

    Jacob, Sharon E.; McGowan, Maria; Silverberg, Nanette B.; Pelletier, Janice L.; Fonacier, Luz; Mousdicas, Nico; Powell, Doug; Scheman, Andrew

    2017-01-01

    Importance Atopic dermatitis (AD) and allergic contact dermatitis (ACD) have a dynamic relationship not yet fully understood. Investigation has been limited thus far by a paucity of data on the overlap of these disorders in pediatric patients. Objective To use data from the Pediatric Contact Dermatitis Registry to elucidate the associations and sensitizations among patients with concomitant AD and ACD. Design, Setting, and Participants This retrospective case review examined 1142 patch test cases of children younger than 18 years, who were registered between January 1, 2015, and December 31, 2015, by 84 health care providers (physicians, nurse practitioners, physician assistants) from across the United States. Data were gathered electronically from multidisciplinary providers within outpatient clinics throughout the United States on pediatric patients (ages 0-18 years). Exposures All participants were patch-tested to assess sensitizations to various allergens; history of AD was noted by the patch-testing providers. Main Outcomes and Measures Primary outcomes were sensitization rates to various patch-tested allergens. Results A total of 1142 patients were evaluated: 189 boys (34.2%) and 363 girls (65.8%) in the AD group and 198 boys (36.1%) and 350 girls (63.9%) in the non-AD group (data on gender identification were missing for 17 patients). Compared with those without AD, patch-tested patients with AD were 1.3 years younger (10.5 vs 11.8 years; P < .001) and had longer history of dermatitis (3.5 vs 1.8 years; P < .001). Patch-tested patients designated as Asian or African American were more likely to have concurrent AD (odds ratio [OR], 1.92; 95% CI, 1.20-3.10; P = .008; and OR, 4.09; 95% CI, 2.70-6.20; P <.001, respectively). Patients with AD with generalized distribution were the most likely to be patch tested (OR, 4.68; 95% CI, 3.50-6.30; P < .001). Patients with AD had different reaction profiles than those without AD, with increased frequency of reactions to cocamidopropyl betaine, wool alcohol, lanolin, tixocortol pivalate, and parthenolide. Patients with AD were also noted to have lower frequency of reaction to methylisothiazolinone, cobalt, and potassium dichromate. Conclusions and Relevance Children with AD showed significant reaction patterns to allergens notable for their use in skin care preparations. This study adds to the current understanding of AD in ACD, and the continued need to investigate the interplay between these disease processes to optimize care for pediatric patients with these conditions. PMID:28241280

  8. The Association of Race/Ethnicity and Patch Test Results: North American Contact Dermatitis Group, 1998-2006.

    PubMed

    Deleo, Vincent Anthony; Alexis, Andrew; Warshaw, Erin M; Sasseville, Denis; Maibach, Howard I; DeKoven, Joel; Zug, Kathryn A; Belsito, Donald V; Fowler, Joseph F; Marks, James G; Mathias, C G Toby; Pratt, Melanie D; Rietschel, Robert L; Storrs, Frances J; Taylor, James S; Zirwas, Matthew

    2016-01-01

    The North American Contact Dermatitis Group patch tests patients with suspected allergic contact dermatitis (ACD) to a broad series of screening allergens and publishes periodic reports. We have previously reported on the association of race and ethnicity with the rates of positive responses to standard patch test allergens. This report extends those observations. The aim of the study was to report the North American Contact Dermatitis Group patch testing results from January 1, 1998, to December 31, 2006, comparing the frequency of positive reactions between white and black subjects. Standardized patch testing with 45 allergens was used at 13 centers in North America. χ analysis of results in black subjects as compared with whites was examined. A total of 19,457 patients were tested; 92.9% (17,803) were white and 7.1% (1,360) were black. The final diagnoses of ACD (whites, 45.9%; blacks, 43.6%) and irritant contact dermatitis (13.0%/13.3%) were similar in the 2 groups. The diagnosis of atopic dermatitis was less common in the white patients (8.9%) as compared with the black patients (13.3%). Positive patch test reactions rates were similar for most allergens. However, statistically, blacks reacted more frequently to p-phenylenediamine (7.0% vs 4.4%, P < 0.001), bacitracin (11.6% vs 8.3%, P = 0.0004), as well as specific rubber accelerators mercaptobenzothiazole (2.7% vs 1.8%), thiuram (6.2% vs 4.3%), and mercapto mix (1.9% vs 0.8%, P < 0.001). Whites had an increase in positive reactions to fragrances (12.12% vs 6.77%, P < 0.0001), formaldehyde (9.25% vs 5.45%, P < 0.0001), and some formaldehyde releaser preservatives used in personal care products and textile resins (9.80% vs 6.18%, P < 0.0001). There were statistically different rates of positive patch test reactions to specific allergens between black and white patients suspected of having ACD. The etiology of these differences is unclear but probably relates to culturally determined exposure patterns rather than genetic differences.

  9. Reactivity to sorbitan sesquioleate affects reactivity to fragrance mix I.

    PubMed

    Geier, Johannes; Schnuch, Axel; Lessmann, Holger; Uter, Wolfgang

    2015-11-01

    Fragrance mix I (FM I) and its single constituents contain 5% and 1% sorbitan sesquioleate (SSO), respectively. SSO is a rare sensitizer and a potential irritant. To determine whether the outcome of the FM I breakdown test is affected by positive patch test reactivity to SSO. A retrospective analysis of data from the Information Network of Departments of Dermatology, 1998-2013, was performed. The full FM I breakdown test including SSO was tested in 2952 patients. Of these, 154 (5.2%) had a positive patch test reaction to SSO 20% pet. and 2709 (91.8%) had a negative patch test reaction. Positive reactions to one or more of the single fragrances contained in the mix were significantly more common (82.5% versus 57.3%) in SSO-positive patients, who also had more multiple reactions than FM I-positive patients with negative SSO reactions (61.5% versus 21.3% patients with reactions to two or more fragrances). Our results indicate that reactivity to SSO markedly affects the outcome of patch testing with FM I and its single constituents. SSO must be an obligatory part of the full FM I breakdown test, and should ideally be included in the baseline series. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Multicenter study of preservative sensitivity in patients with suspected cosmetic contact dermatitis in Korea.

    PubMed

    Lee, Sang S; Hong, Dong K; Jeong, Nam J; Lee, Jeung H; Choi, Yun-Seok; Lee, Ai-Young; Lee, Cheol-Heon; Kim, Kea J; Park, Hae Y; Yang, Jun-Mo; Lee, Ga-Young; Lee, Joon; Eun, Hee C; Moon, Kee-Chan; Seo, Seong J; Hong, Chang K; Lee, Sang W; Choi, Hae Y; Lee, Jun Y

    2012-08-01

    As many new cosmetic products are introduced into the market, attention must be given to contact dermatitis, which is commonly caused by cosmetics. We investigate the prevalence of preservative allergy in 584 patients with suspected cosmetic contact dermatitis at 11 different hospitals. From January 2010 to March 2011, 584 patients at 11 hospital dermatology departments presented with cosmetic contact dermatitis symptoms. These patients were patch-tested for preservative allergens. An irritancy patch test performed on 30 control subjects using allergens of various concentrations showed high irritancy rates. Preservative hypersensitivity was detected in 41.1% of patients. Allergens with the highest positive test rates were benzalkonium chloride (12.1%), thimerosal (9.9%) and methylchloroisothiazolinone/methylisothiazolinone (MCI/MI) (5.5%). Benzalkonium chloride and chlorphenesin had the highest irritancy rate based on an irritancy patch test performed using various concentrations. Seven of 30 normal subjects had a positive irritant patch reading with 0.1% benzalkonium chloride and eight of 30 normal subjects had a positive irritant patch reading at 4 days with 0.5% chlorphenesin in petrolatum. Although benzalkonium chloride was highly positive for skin reactions in our study, most reactions were probably irritation. MCI/MI and thimerosal showed highly positive allergy reactions in our study. The optimum concentration of chlorphenesin to avoid skin reactions is less than 0.5%. © 2012 Japanese Dermatological Association.

  11. Patch test reactions to metal salts in patients with different types of dermatitis.

    PubMed

    Turčić, Petra; Marinović Kulišić, Sandra; Lipozenčić, Jasna

    2013-01-01

    Metal allergies can be a clinical problem, especially in atopic individuals. This study is unique and contributes with new knowledge in everyday life skin care of irritant and atopic dermatitis patients. The aim of the study was to determine the frequency of positive patch test reactions to metal contact allergens (potassium dichromate, cobalt chloride, nickel sulfate, white mercury precipitate) in patients diagnosed with allergic contact dermatitis, irritant contact dermatitis, and atopic dermatitis. Between 2007 and 2011, patch testing was performed in 2185 patients according to the International Contact Dermatitis Research Group technique. Study results showed statistically significant differences in patch test responses to 2 allergens, nickel sulfate (χ(2)=24.22; p<0.001) and cobalt chloride (χ(2)=22.72; p<0.001). Nickel sulfate was the most common allergen in allergic contact dermatitis and atopic dermatitis, while for irritant contact dermatitis the most common allergen was cobalt chloride. Among the 4 tested metal allergens, the most common and relevant was nickel sulfate (χ(2)=17.25; p<0.004), found in almost all study subjects. In conclusion, the increased awareness of allergens and their potential sources may help limit the use of these chemicals in consumer product manufacturing.

  12. Flow cytometric analysis of regulatory T cells during hyposensitization of acquired allergic contact dermatitis.

    PubMed

    Fraser, Kathleen; Abbas, Mariam; Hull, Peter R

    2014-01-01

    We previously demonstrated that repeated intradermal steroid injections administered at weekly intervals into positive patch-test sites induce hyposensitization and desensitization. To examine changes in CD4CD25CD127lo/ regulatory T cells during the attenuation of the patch-test response. Ten patients with known allergic contact dermatitis were patch tested weekly for 10 weeks. The patch-test site was injected intradermally with 2 mg triamcinolone. At weeks 1 and 7, a biopsy was performed on the patch-test site in 6 patients, and flow cytometry was performed assessing CD4CD25CD127lo/ regulatory T cells. Secondary outcomes were clinical score, reaction size, erythema, and temperature. Statistical analysis included regression, correlation, and repeated-measures analysis of variance. The percentage of CD4CD25CD127lo/ regulatory T cells, measured by flow cytometry, increased from week 1 to week 7 by an average of 19.2%. The average grade of patch-test reaction decreased from +++ (vesicular reaction) to ++ (palpable erythema). The mean drop in temperature following treatment was 0.28°C per week. The mean area decreased 8.6 mm/wk over 10 weeks. Intradermal steroid injections of weekly patch-test reactions resulted in hyposensitization of the allergic contact dermatitis reaction. CD4CD25CD127lo/ regulatory T cells showed a tendency to increase; however, further studies are needed to determine if this is significant.

  13. Patch test reactions associated with sunscreen products and the importance of testing to an expanded series: retrospective analysis of North American Contact Dermatitis Group data, 2001 to 2010.

    PubMed

    Warshaw, Erin M; Wang, Michael Z; Maibach, Howard I; Belsito, Donald V; Zug, Kathryn A; Taylor, James S; Mathias, C G Toby; Sasseville, Denis; Zirwas, Matthew J; Fowler, Joseph F; DeKoven, Joel G; Fransway, Anthony F; DeLeo, Vincent A; Marks, James G; Pratt, Melanie D; Storrs, Frances J

    2013-01-01

    Both active and inactive ingredients in sunscreen may cause contact dermatitis. This study aimed to describe allergens associated with a sunscreen source. A cross-sectional analysis of patients patch tested by the North American Contact Dermatitis Group between 2001 and 2010 was performed. Of 23,908 patients patch tested, 219 (0.9%) had sunscreen coded as an allergen source. Patients who were male, with occupational dermatitis, or older (older than 40 years) had significantly lower rates of allergic reactions to sunscreens; the most commonly affected areas were the face and exposed sites (P < 0.0001). The top 3 most frequent allergens in sunscreens were benzophenone-3 (70.2% for 10% concentration, 64.4% for 3% concentration), DL-alpha-tocopherol (4.8%), and fragrance mix I (4.0%). Less than 40% of positive patch test reactions were detected by the North American Contact Dermatitis Group screening series of 65 to 70 allergens. A supplemental antigen series is important in detecting allergy to sunscreens.

  14. Can the epoxides of cinnamyl alcohol and cinnamal show new cases of contact allergy?

    PubMed

    Hagvall, Lina; Niklasson, Ida B; Luthman, Kristina; Karlberg, Ann-Therese

    2018-06-01

    Cinnamyl alcohol is considered to be a prohapten and prehapten with cinnamal as the main metabolite. However, many individuals who are allergic to cinnamyl alcohol do not react to cinnamal. Sensitizing epoxides of cinnamyl alcohol and cinnamal have been identified as metabolites and autoxidation products of cinnamyl alcohol. To investigate the clinical relevance of contact allergy to epoxycinnamyl alcohol and epoxycinnamal. Irritative effects of the epoxides were investigated in 12 dermatitis patients. Epoxycinnamyl alcohol and epoxycinnamal were patch tested in 393 and 390 consecutive patients, respectively. In parallel, cinnamyl alcohol and cinnamal were patch tested in 607 and 616 patients, respectively. Both epoxides were irritants, but no more positive reactions were detected than when testing was performed with cinnamyl alcohol and cinnamal. Late allergic reactions to epoxycinnamyl alcohol were observed. In general, patients with late reactions showed doubtful or positive reactions to cinnamal and fragrance mix I at regular patch testing. The investigated epoxides are not important haptens in contact allergy to cinnamon fragrance. The high frequency of fragrance allergy among patients included in the irritancy study showed the difficulty of suspecting fragrance allergy on the basis of history; patch testing broadly with fragrance compounds is therefore important. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Allergic contact dermatitis from a natural deodorant: a report of 4 cases associated with lichen acid mix allergy.

    PubMed

    Sheu, Mary; Simpson, Eric L; Law, Sandra V; Storrs, Frances J

    2006-08-01

    Botanical ingredients used in personal care products are a significant and underreported cause of allergic contact dermatitis. To evaluate allergic contact dermatitis from a widely-used botanical deodorant. We conducted patch testing in four patients who were using the botanical deodorant and were referred to the contact dermatitis clinic; three patients had axillary dermatitis and one had dermatitis of the external ear. All four patients had positive patch test reactions to lichen acid mix and D-usnic acid. Of the three patients who were patch tested to the botanical deodorant, all had positive reactions. We did not test to the specific lichen used in the natural deodorant but rather used our own lichen acid mix and d-usnic acid in addition to testing to the actual product. One of the patients declined to be tested with the natural deodorant, but did test positive to the lichen acid mix and d-usnic acid. Personal care products such as deodorants may represent a new route of exposure to lichen extract, a known allergen.

  16. Contact allergy in cheilitis.

    PubMed

    O'Gorman, Susan M; Torgerson, Rochelle R

    2016-07-01

    Recalcitrant non-actinic cheilitis may indicate contact allergy. This study aimed to determine the prevalence of allergic contact cheilitis (ACC) in patients with non-actinic cheilitis and to identify the most relevant allergens. We used an institutional database to identify patients with non-actinic cheilitis who underwent patch testing between January 1, 2001, and August 31, 2011, and conducted a retrospective review of patch test results in these patients. Additional data were obtained from institutional electronic medical records. Ninety-one patients (70 [77%] female; mean age: 51 years) were included in the study. Almost half (41 [45%]) had a final diagnosis of ACC. Patch testing was performed in line with universally accepted methods, with application on day 1, allergen removal and an initial reading on day 3, and the final reading on day 5. The allergens of most significance were fragrance mix, Myroxylon pereirae resin, dodecyl gallate, octyl gallate, and benzoic acid. Nickel was the most relevant metal allergen. Contact allergy is an important consideration in recalcitrant cheilitis. Fragrances, antioxidants, and preservatives dominated the list of relevant allergens in our patients. Nickel and gold were among the top 10 allergens. Almost half (45%) of these patients had a final diagnosis of ACC. Patch testing beyond the oral complete series should be undertaken in any investigation of non-actinic cheilitis. © 2015 The International Society of Dermatology.

  17. Cross-reactions among parabens, para-phenylenediamine, and benzocaine: a retrospective analysis of patch testing.

    PubMed

    Turchin, Irina; Moreau, Linda; Warshaw, Erin; Sasseville, Denis

    2006-12-01

    Parabens are alkyl ester derivatives of para-hydroxybenzoic acid and are the most commonly used preservatives in the cosmetic industry. Cross-reactions with para-amino compounds, namely, benzocaine and para-phenylenediamine (PPD), have been reported but are thought to be extremely rare. To evaluate the rate of cross-reactivity between parabens, PPD, and benzocaine in a population of patients patch-tested in a hospital-based contact dermatitis clinic. A retrospective analysis of 4,368 patients consecutively patch-tested between July 1989 and June 2005. Our study demonstrated that the rate of cross-reactions to parabens in PPD- and benzocaine-positive patients combined is 2%. This cross-reaction rate is significant in the tested population but still falls within the previously reported rates of sensitivity to parabens in the general population (0 to 3.5%).

  18. Contact sensitivities in palmar plantar pustulosis (acropustulosis).

    PubMed

    Yiannias, J A; Winkelmann, R K; Connolly, S M

    1998-09-01

    Acropustulosis, or chronic palmar plantar pustulosis (PPP), is a phenomenon of recurrent sterile pustules, erythema, and scaling affecting the palms and soles. Its pathogenesis is unclear, and it is difficult to treat. The purpose of this study was to elucidate further the factors involved in causing PPP, thereby enhancing the ability to manage this disease. All cases of PPP seen at Mayo Clinic Scottsdale from 1987 to 1993 were reviewed. 21 patients with PPP were identified, 15 of whom had been patch tested. 9 of the 15 patients (60%) showed positive patch test results. Fragrance was the most common sensitivity, but nickel, formaldehyde, para-phenylenediamine, thiuram, neomycin, mercury, balsam of Peru, and cinnamic aldehyde sensitivities were demonstrated. Less important factors included atopy, fungal and bacterial infections, and irritation. Although the mechanism of this sterile pustulosis response does not depend solely on delayed hypersensitivity mechanisms, we believe that we have demonstrated such a large number of positive patch tests in this chronic pustular dermatosis that patch testing should be considered in the routine work-up of these patients.

  19. Diagnostic patch testing following tuberculosis-associated cutaneous adverse drug reactions induces systemic reactions in HIV-infected persons.

    PubMed

    Lehloenya, R J; Todd, G; Wallace, J; Ngwanya, M R; Muloiwa, R; Dheda, K

    2016-07-01

    The incidence of cutaneous adverse drug reactions (CADRs) to first-line antituberculosis drugs (FLTDs) is higher in HIV-tuberculosis coinfection. However, the utility of patch testing to identify the offending drug in this patient subgroup has been poorly studied. To identify drugs causing adverse drug reactions in patients with HIV-tuberculosis coinfection. Fourteen consecutive patients underwent diagnostic work-up (patch testing followed by a skin prick test and an oral rechallenge) to pinpoint the offending drug after developing FLTD-associated CADR, which included drug rash with eosinophilia and systemic symptoms (n = 12), Stevens-Johnson syndrome (SJS, n = 1) and toxic epidermal necrolysis/SJS overlap (n = 1). A positive reaction to any of the three diagnostic modalities eliminated that drug from the regimen. Once patients were clinically stable postreaction, sequential and additive rechallenge with FLTDs was initiated. Eleven of the 14 participants with FLTD-associated CADR were HIV infected (median CD4 count 149 cells mm(-3) ). In this subgroup, patch testing resulted in generalized systemic reactions in 10 of 11 patients (91%). These included rash in 10 of 13 reactions (77%), eosinophilia in eight (62%), transaminitis in seven (54%) and fever in five (38%). Isoniazid caused six of 13 (46%) generalized systemic reactions, rifampicin four (31%), ethambutol two (15%) and pyrazinamide one reaction. Using the Common Terminology Criteria for Adverse Events, five of 13 reactions were mild, six were moderate and two were severe. There were no life-threatening or fatal reactions. In HIV-infected persons with tuberculosis-associated CADR, although patch-testing reactions to FLTD are common and tend to be associated with systemic features, they are not life threatening or fatal. These data inform clinical practice in HIV-endemic settings. © 2016 British Association of Dermatologists.

  20. Results of patch testing with lavender oil in Japan.

    PubMed

    Sugiura, M; Hayakawa, R; Kato, Y; Sugiura, K; Hashimoto, R

    2000-09-01

    We report the annual results of patch testing with lavender oil for a 9-year period from 1990 to 1998 in Japan. Using Finn Chambers and Scanpor tape, we performed 2-day closed patch testing with lavender oil 20% pet. on the upper back of each patient suspected of having cosmetic contact dermatitis. We compared the frequency of positive patch tests to lavender oil each year with those to other fragrances. We diagnosed contact allergy when patch test reactions were + or <+ at 1 day after removal. The positivity rate of lavender oil was 3.7% (0-13.9%) during the 9-year period from 1990 to 1998. The positivity rate of lavender oil increased suddenly in 1997. Recently, in Japan, there has been a trend for aromatherapy using lavender oil. With this trend, placing dried lavender flowers in pillows, drawers, cabinets, or rooms has become a new fashion. We asked patients who showed a positive reaction to lavender oil about their use of dried lavender flowers. We confirmed the use of dried lavender flowers in 5 cases out of 11 positive cases in 1997 and 8 out of 15 positive cases in 1998. We concluded that the increase in patch test positivity rates to lavender oil in 1997 and 1998 was due to the above fashion, rather than due to fragrances in cosmetic products.

  1. A rare allergy to a polyether dental impression material.

    PubMed

    Mittermüller, Pauline; Szeimies, Rolf-Markus; Landthaler, Michael; Schmalz, Gottfried

    2012-08-01

    Polyether impression materials have been used in dentistry for more than 40 years. Allergic reactions to these materials such as reported in the 1970s ceased after replacement of a catalyst. Very recently, however, patients have started to report symptoms that suggest a new allergic reaction from polyether impression materials. Here, we report on the results of allergy testing with polyether impression materials as well as with its components. Eight patients with clinical symptoms of a contact allergy (swelling, redness or blisters) after exposure to a polyether impression material were subjected to patch tests, two of them additionally to a prick test. A further patient with atypical symptoms of an allergy (nausea and vomiting after contact with a polyether impression material in the oral cavity) but with a history of other allergic reaction was also patch tested. The prick tests showed no immediate reactions in the two patients tested. In the patch tests, all eight patients with typical clinical symptoms showed positive reactions to the mixed polyether impression materials, to the base paste or to a base paste component. The patient with the atypical clinical symptoms did not show any positive patch test reactions. Polyether impression materials may evoke type IV allergic reactions. The causative agent was a component of the base paste. In consideration of the widespread use of this impression material (millions of applications per year) and in comparison to the number of adverse reactions from other dental materials, the number of such allergic reactions is very low. In very scarce cases, positive allergic reactions to polyether impression materials are possible.

  2. Simultaneous patch testing with fragrance mix I, fragrance mix II and their ingredients in southern Sweden between 2009 and 2015.

    PubMed

    Mowitz, Martin; Svedman, Cecilia; Zimerson, Erik; Isaksson, Marléne; Pontén, Ann; Bruze, Magnus

    2017-11-01

    Fragrance mix I (FM I) and fragrance mix II (FM II) are included in the European baseline series as screening substances for fragrance contact allergy. To investigate the frequency of allergic reactions to FM I, FM II and their ingredients in consecutively patch tested patients. A retrospective analysis of data from 4430 patients patch tested between 2009 and 2015 was performed. Of the patients, 6.5% were FM I-positive and 3.2% were FM II-positive. Forty-five per cent of FM I-positive patients did not have positive reactions to FM I ingredients. Thirty-five per cent of those who were FM II-positive did not have positive reactions to FM II ingredients. Twenty-seven per cent of those with positive reactions to one or more of the FM I ingredients were FM I-negative, and 36% of those who had positive reactions to one or more of the FM II ingredients were FM II-negative. The allergens with the highest pick-up rates were Evernia prunastri (1.8%), cinnamal (1.3%), citral (1.2%), and hydroxyisohexyl 3-cyclohexene carboxaldehyde (1.2%). Significant differences were observed in the proportions of positive reactions to FM I, FM II, eugenol, isoeugenol, and farnesol when results from patch testing with materials from different suppliers were compared. There is a risk of missing fragrance contact allergy when testing with only the fragrance mixes is performed. The use of preparations from different suppliers may affect the patch test results. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Performance of a commercially available plant allergen series in the assessment of suspected occupational contact dermatitis to plants in north Indian patients.

    PubMed

    De, Dipankar; Khullar, Geeti; Handa, Sanjeev

    2015-01-01

    Parthenium hysterophorus is the leading cause of phytogenic allergic contact dermatitis in India. The Indian Standard Series currently supplied by Systopic Laboratories Ltd and manufactured by Chemotechnique Diagnostics ® contains parthenolide as the only allergen representing plant allergens. The study was conducted to assess the performance of the Chemotechnique plant series (PL-1000), consisting of 14 allergens, in patients with clinically suspected occupational contact dermatitis to plant allergens. Ninety patients were patch tested with the Chemotechnique plant series from 2011 to 2013. Demographic details, clinical diagnosis and patch test results were recorded in the contact dermatitis clinic proforma. Of 90 patients, 24 (26.7%) showed positive reactions to one or more allergens in the plant series. Positive patch tests were elicited most commonly by sesquiterpene lactone mix in 19 (78.6%) patients, followed by parthenolide in 14 (57.1%), Achillea millefolium in 10 (42.9%) and others in decreasing order. The plant allergen series prepared by Chemotechnique Diagnostics is possibly not optimal for diagnosing suspected allergic contact dermatitis to plants in north Indians. Sesquiterpene lactone mix should replace parthenolide as the plant allergen in the Indian Standard Series until relevant native plant extracts are commercially available for patch testing.

  4. Occupationally related contact dermatitis in North American food service workers referred for patch testing, 1994 to 2010.

    PubMed

    Warshaw, Erin M; Kwon, Gina P; Mathias, C G Toby; Maibach, Howard I; Fowler, Joseph F; Belsito, Donald V; Sasseville, Denis; Zug, Kathryn A; Taylor, James S; Fransway, Anthony F; Deleo, Vincent A; Marks, James G; Pratt, Melanie D; Storrs, Frances J; Zirwas, Matthew J; Dekoven, Joel G

    2013-01-01

    Contact dermatoses are common in food service workers (FSWs). This study aims to (1) determine the prevalence of occupationally related contact dermatitis among FSWs patch tested by the North American Contact Dermatitis Group (NACDG) and (2) characterize responsible allergens and irritants as well as sources. Cross-sectional analysis of patients patch tested by the NACDG, 1994 to 2010, was conducted. Of 35,872 patients patch tested, 1237 (3.4%) were FSWs. Occupationally related skin disease was significantly more common in FSWs when compared with employed non-FSWs. Food service workers were significantly more likely to have hand (P < 0.0001) and arm (P < 0.0006) involvement. The rates for irritant and allergic contact dermatitis in FSWs were 30.6% and 54.7%, respectively. Although the final diagnosis of irritant contact dermatitis was statistically higher in FSWs as compared with non-FSWs, allergic contact dermatitis was lower in FSWs as compared with non-FSWs. The most frequent currently relevant and occupationally related allergens were thiuram mix (32.5%) and carba mix (28.9%). Gloves were the most common source of responsible allergens. The NACDG standard tray missed at least 1 occupationally related allergen in 38 patients (4.3%). Among FSWs patch tested by the NACDG between 1994 and 2010, the most common allergens were thiuram mix and carba mix. Gloves were the most common source of responsible allergens.

  5. Lidocaine 20% patch vs lidocaine 5% gel for topical anaesthesia of oral mucosa.

    PubMed

    Bågesund, Mats; Tabrizi, Parisa

    2008-11-01

    Topical anaesthetics are important to provide pain control at dental injection. The aim was to evaluate the effectiveness of the intraoral topical anaesthetics lidocaine 20% patch (DentiPatch) and lidocaine 5% gel. The randomized unblinded cross-over study included 31 patients (ten boys, 21 girls) aged 13.5 +/- 2.5 years. Application of lidocaine patch or gel was randomly used at first and second visit in the upper premolar region. Heart rate was measured before and at each needle insertion after 2.5, 5, and 15 min and at injection after 15 min. Discomfort and pain were expressed in visual analogue scales (VAS). Paired t-test and Mann-Whitney U-test were used for statistic analyses. Heart rate at buccal injection decreased more when the patch was used (P = 0.0149). Heart rate was lower at the second visit (P = 0.0287). Patients expressed less discomfort when the patch was used on both buccal (P = 0.0150) and palatal (P = 0.0391) site. Boys had lower heart rate and VAS pain scale ratings than girls. Good pain control can reduce the patients' anxiety level--expressed in heart rate--at the second appointment. The patch and gel seem to provide similar pain reduction at needle stick and injection of local anaesthetics.

  6. Contact allergy to epoxy resin: risk occupations and consequences.

    PubMed

    Bangsgaard, Nannie; Thyssen, Jacob Pontoppidan; Menné, Torkil; Andersen, Klaus Ejner; Mortz, Charlotte G; Paulsen, Evy; Sommerlund, Mette; Veien, Niels Kren; Laurberg, Grete; Kaaber, Knud; Thormann, Jens; Andersen, Bo Lasthein; Danielsen, Anne; Avnstorp, Christian; Kristensen, Berit; Kristensen, Ove; Vissing, Susanne; Nielsen, Niels Henrik; Johansen, Jeanne Duus

    2012-08-01

    Epoxy resin monomers are strong skin sensitizers that are widely used in industrial sectors. In Denmark, the law stipulates that workers must undergo a course on safe handling of epoxy resins prior to occupational exposure, but the effectiveness of this initiative is largely unknown. To evaluate the prevalence of contact allergy to epoxy resin monomer (diglycidyl ether of bisphenol A; MW 340) among patients with suspected contact dermatitis and relate this to occupation and work-related consequences. The dataset comprised 20 808 consecutive dermatitis patients patch tested during 2005-2009. All patients with an epoxy resin-positive patch test were sent a questionnaire. A positive patch test reaction to epoxy resin was found in 275 patients (1.3%), with a higher proportion in men (1.9%) than in women (1.0%). The prevalence of sensitization to epoxy resin remained stable over the study period. Of the patients with an epoxy resin-positive patch test, 71% returned a questionnaire; 95 patients had worked with epoxy resin in the occupational setting, and, of these, one-third did not use protective gloves and only 50.5% (48) had participated in an educational programme. The 1% prevalence of epoxy resin contact allergy is equivalent to reports from other countries. The high occurrence of epoxy resin exposure at work, and the limited use of protective measures, indicate that reinforcement of the law is required. © 2012 John Wiley & Sons A/S.

  7. Footwear contact dermatitis from dimethyl fumarate.

    PubMed

    Švecová, Danka; Šimaljakova, Maria; Doležalová, Anna

    2013-07-01

    Dimethyl fumarate (DMF) is an effective inhibitor of mold growth. In very low concentrations, DMF is a potent sensitizer that can cause severe allergic contact dermatitis (ACD). It has been identified as the agent responsible for furniture contact dermatitis in Europe. The aim of this study was to evaluate patients in Slovakia with footwear ACD associated with DMF, with regard to clinical manifestations, patch test results, and results of chemical analysis of their footwear. Nine patients with suspected footwear contact dermatitis underwent patch testing with the following allergens: samples of their own footwear, commercial DMF, the European baseline, shoe screening, textile and leather dye screening, and industrial biocides series. The results were recorded according to international guidelines. The content of DMF in footwear and anti-mold sachets was analyzed using gas chromatography and mass spectrometry. Acute ACD was observed in nine Caucasian female patients. All patients developed delayed sensitization, as demonstrated by positive patch testing using textile footwear lining. Seven patients were patch tested with 0.1% DMF, and all seven were positive. Chemical analysis of available footwear showed that DMF was present in very high concentrations (25-80 mg/Kg). Dimethyl fumarate is a new footwear allergen and was responsible for severe ACD in our patients. To avoid an increase in the number of cases, the already approved European preventive measures should be accepted and commonly employed. © 2013 The International Society of Dermatology.

  8. Fragrance allergy in patients with hand eczema - a clinical study.

    PubMed

    Heydorn, Siri; Johansen, Jeanne Duus; Andersen, Klaus E; Bruze, Magnus; Svedman, Cecilia; White, Ian R; Basketter, David A; Menné, Torkil

    2003-06-01

    Fragrance allergy and hand eczema are both common among dermatological patients. Fragrance mix (FM) and its constituents have a recognized relevance to exposure to fine fragrances and cosmetic products. Based on extensive chemical analysis and database search, a new selection of fragrances was established, including 14 known fragrance allergens present in products to which hand exposure would occur. A non-irritating patch-test concentration for some fragrances was established in 212 consecutive patients. 658 consecutive patients presenting with hand eczema were patch tested with the European standard series and the developed selection of fragrances. 67 (10.2%) of the 658 patients had a positive reaction to 1 or more of our selection of fragrance chemicals present in the new selection. The most common reactions to fragrances not included in the FM were to citral, Lyral (hydroxyisohexyl-3-cyclohexene carboxaldehyde) and oxidized l-limonene. A concomitant reaction to the FM identified potential fragrance allergy in less than (1/2) of these patients. Exposure assessment and a statistically significant association between a positive patch test to our selected fragrances and patients' history support the relevance of this selection of fragrances. Those with a positive reaction to our selected fragrances were significantly more likely to have 1 or more positive patch tests in the standard series. This observation is the basis for the hypothesis concerning cross-reactivity and the effect of simultaneous exposure. The study found that fragrance allergy could be a common problem in patients with eczema on the hands.

  9. The fragrance hand immersion study - an experimental model simulating real-life exposure for allergic contact dermatitis on the hands.

    PubMed

    Heydorn, S; Menné, T; Andersen, K E; Bruze, M; Svedman, C; Basketter, D; Johansen, J D

    2003-06-01

    Recently, we showed that 10 x 2% of consecutively patch-tested hand eczema patients had a positive patch test to a selection of fragrances containing fragrances relevant to hand exposure. In this study, we used repeated skin exposure to a patch test-positive fragrance allergen in patients previously diagnosed with hand eczema to explore whether immersion of fingers in a solution with or without the patch-test-positive fragrance allergen would cause or exacerbate hand eczema on the exposed finger. The study was double blinded and randomized. All participants had a positive patch test to either hydroxycitronellal or Lyral (hydroxyisohexyl 3-cyclohexene carboxaldehyde). Each participant immersed a finger from each hand, once a day, in a solution containing the fragrance allergen or placebo. During the first 2 weeks, the concentration of fragrance allergen in the solution was low (approximately 10 p.p.m.), whilst during the following 2 weeks, the concentration was relatively high (approximately 250 p.p.m.), imitating real-life exposure to a household product like dishwashing liquid diluted in water and the undiluted product, respectively. Evaluation was made using a clinical scale and laser Doppler flow meter. 3 of 15 hand eczema patients developed eczema on the finger immersed in the fragrance-containing solution, 3 of 15 on the placebo finger and 3 of 15 on both fingers. Using this experimental exposure model simulating real-life exposure, we found no association between immersion of a finger in a solution containing fragrance and development of clinically visible eczema on the finger in 15 participants previously diagnosed with hand eczema and with a positive patch test to the fragrance in question.

  10. Contact allergy to common ingredients in hair dyes.

    PubMed

    Søsted, Heidi; Rustemeyer, Thomas; Gonçalo, Margarida; Bruze, Magnus; Goossens, An; Giménez-Arnau, Ana M; Le Coz, Christophe J; White, Ian R; Diepgen, Thomas L; Andersen, Klaus E; Agner, Tove; Maibach, Howard; Menné, Torkil; Johansen, Jeanne D

    2013-07-01

    p-Phenylenediamine (PPD) is the primary patch test screening agent for hair dye contact allergy, and approximately 100 different hair dye chemicals are allowed. To examine whether PPD is an optimal screening agent for diagnosing hair dye allergy or whether other clinically important sensitizers exist. Two thousand nine hundred and thirty-nine consecutive patients in 12 dermatology clinics were patch tested with five hair dyes available from patch test suppliers. Furthermore, 22 frequently used hair dye ingredients not available from patch test suppliers were tested in subgroups of ~500 patients each. A positive reaction to PPD was found in 4.5% of patients, and 2.8% reacted to toluene-2,5-diamine (PTD), 1.8% to p-aminophenol, 1% to m-aminophenol, and 0.1% to resorcinol; all together, 5.3% (n = 156). Dying hair was the most frequently reported cause of the allergy (55.4%); so-called 'temporary henna' tattoos were the cause in 8.5% of the cases. p-Methylaminophenol gave a reaction in 20 patients (2.2%), 3 of them with clinical relevance, and no co-reaction with the above five well-known hair dyes. Hair dyes are the prime cause of PPD allergy. PPD identifies the majority of positive reactions to PTD, p-aminophenol and m-aminophenol, but not all, which justifies additional testing with hair dye ingredients from the used product. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Contact Allergy to Hydroperoxides of Linalool and D-Limonene in a US Population.

    PubMed

    Nath, Neel Som; Liu, Beiyu; Green, Cynthia; Atwater, Amber Reck

    Linalool and D-limonene are common fragrance ingredients that readily oxidize on exposure to air. The resulting hydroperoxides of linalool and D-limonene have been shown to have high frequencies of positive patch test reactions in several European and international studies. The aim of the study was to investigate the prevalence of contact allergy to the hydroperoxides of linalool and D-limonene in a US population. In this retrospective study, 103 patients with suspected fragrance allergy were patch tested to linalool 10% petrolatum (pet), hydroperoxides of linalool 1% pet, D-limonene 10% pet, and/or the hydroperoxides of D-limonene 0.3% pet between July 9, 2014, and October 25, 2016. In this study, the frequency of positive patch test reactions to the hydroperoxides of linalool is 20% (19/96), and the frequency of positive reactions to the hydroperoxides of D-limonene is 8% (7/90). These high frequencies suggest that patch testing to the hydroperoxides of linalool and limonene should be performed in all patients with suspected fragrance allergy.

  12. Multicentre study of allergic contact cheilitis from toothpastes.

    PubMed

    Francalanci, S; Sertoli, A; Giorgini, S; Pigatto, P; Santucci, B; Valsecchi, R

    2000-10-01

    The present work reports the results of a multicentre study of toothpaste allergic contact cheilitis (TACC) conducted by GIRDCA (Gruppo Italiano Ricerca Dermatiti da Contatto e Ambientali). The study examined 54 patients with eczematous lesions on the lips, the possible cause of which was suspected to be the use of toothpastes. Patch tests were conducted with a standard series, a specially-targeted series (toothpaste cheilitis series, TCS), and with suspected toothpaste(s). A stop-restart test (SRT) was carried out with these, together with a use test to identify possible alternative products. The TCS produced 17 positive reactions in 13 patients, the most frequent being to spearmint oil. Of the 54 patients, 5 displayed positive reactions only to the TCS. The patch tests with toothpaste produced positive reactions in 11/32 patients, the SRT a positive response in 10/12 cases. The diagnosis of TACC was confirmed in 15/54 patients. Alternative products were identified for 5 patients. In conclusion, the allergens most frequently responsible for TACC were the flavourings, and the additional series proved to be useful in many cases (together with patch tests with toothpastes and the SRT) for correct diagnosis and to initiate effective prevention.

  13. Methylisothiazolinone testing at 2000 ppm: a prevalent sensitizer for allergic contact dermatitis.

    PubMed

    Ham, Kaiya; Posso-De Los Rios, Claudia J; Gooderham, Melinda

    2015-01-01

    Methylchloroisothiazolinone (MCI) and methylisothiazolinone (MI) have been identified as potent allergens. The optimal MI concentration for patch testing for reaction to these agents has not yet been identified, but it has been suggested that testing MI at 2000 ppm may reduce false-negative reactions. The aim of this study was to report allergic reactions to MI and MCI/MI detected in a community dermatology practice setting in Ontario, Canada. The patch test records of patients with suspected allergic contact dermatitis seen between October 2007 and June 2014 were reviewed. We compared positive patch testing before and after December 2011 when a higher MI concentration was used (2000 ppm aqueous) in addition to the baseline series MCI/MI at 100 ppm. A total of 794 patient records were reviewed. There were 38 true-positive reactions to MI or MCI/MI. Of these 38 patients, 26 (68%) were female. We detected an overall increase in the rate of positive patch testing to MCI/MI, MI alone, or both from 3.13% to 7.45% when MI concentration was introduced at 2000 ppm aqueous. Occupational differences existed between sexes. The addition of MI at 2000 ppm to our screening series effectively increased the detection of MI-induced allergic contact dermatitis.

  14. Image-Based Patient-Specific Ventricle Models with Fluid-Structure Interaction for Cardiac Function Assessment and Surgical Design Optimization

    PubMed Central

    Tang, Dalin; Yang, Chun; Geva, Tal; del Nido, Pedro J.

    2010-01-01

    Recent advances in medical imaging technology and computational modeling techniques are making it possible that patient-specific computational ventricle models be constructed and used to test surgical hypotheses and replace empirical and often risky clinical experimentation to examine the efficiency and suitability of various reconstructive procedures in diseased hearts. In this paper, we provide a brief review on recent development in ventricle modeling and its potential application in surgical planning and management of tetralogy of Fallot (ToF) patients. Aspects of data acquisition, model selection and construction, tissue material properties, ventricle layer structure and tissue fiber orientations, pressure condition, model validation and virtual surgery procedures (changing patient-specific ventricle data and perform computer simulation) were reviewed. Results from a case study using patient-specific cardiac magnetic resonance (CMR) imaging and right/left ventricle and patch (RV/LV/Patch) combination model with fluid-structure interactions (FSI) were reported. The models were used to evaluate and optimize human pulmonary valve replacement/insertion (PVR) surgical procedure and patch design and test a surgical hypothesis that PVR with small patch and aggressive scar tissue trimming in PVR surgery may lead to improved recovery of RV function and reduced stress/strain conditions in the patch area. PMID:21344066

  15. Patch Testing for Evaluation of Hypersensitivity to Implanted Metal Devices: A Perspective From the American Contact Dermatitis Society.

    PubMed

    Schalock, Peter C; Crawford, Glen; Nedorost, Susan; Scheinman, Pamela L; Atwater, Amber Reck; Mowad, Christen; Brod, Bruce; Ehrlich, Alison; Watsky, Kalman L; Sasseville, Denis; Silvestri, Dianne; Worobec, Sophie M; Elliott, John F; Honari, Golara; Powell, Douglas L; Taylor, James; DeKoven, Joel

    2016-01-01

    The American Contact Dermatitis Society recognizes the interest in the evaluation and management of metal hypersensitivity reactions. Given the paucity of robust evidence with which to guide our practices, we provide reasonable evidence and expert opinion-based guidelines for clinicians with regard to metal hypersensitivity reaction testing and patient management. Routine preoperative evaluation in individuals with no history of adverse cutaneous reactions to metals or history of previous implant-related adverse events is not necessary. Patients with a clear self-reported history of metal reactions should be evaluated by patch testing before device implant. Patch testing is only 1 element in the assessment of causation in those with postimplantation morbidity. Metal exposure from the implanted device can cause sensitization, but a positive metal test does not prove symptom causality. The decision to replace an implanted device must include an assessment of all clinical factors and a thorough risk-benefit analysis by the treating physician(s) and patient.

  16. Patch test standard series recommended by the Brazilian Contact Dermatitis Study Group during the 2006-2011 period.

    PubMed

    Duarte, Ida Alzira Gomes; Tanaka, Greta Merie; Suzuki, Nathalie Mie; Lazzarini, Rosana; Lopes, Andressa Sato de Aquino; Volpini, Beatrice Mussio Fornazier; Castro, Paulo Carrara de

    2013-01-01

    A retrospective study was carried out between 2006-2011. Six hundred and eighteen patients with suspected allergic contact dermatitis underwent the standard patch test series recommended by the Brazilian Contact Dermatitis Research Group. The aim of our study was to evaluate the variation of positive patch-test results from standard series year by year. The most frequently positive allergens were: nickel sulfate, thimerosal and potassium bichromate. Decrease of positive patch-test results over the years was statistically significant for: lanolin (p=0.01), neomycin (p=0.01) and anthraquinone (p=0.04). A follow-up study should be useful in determining which allergens could be excluded from standard series, as they may represent low sensitization risk.

  17. Two decades of p-phenylenediamine and toluene-2,5-diamine patch testing - focus on co-sensitizations in the European baseline series and cross-reactions with chemically related substances.

    PubMed

    Vogel, Tatiana A; Heijnen, Rakita W; Coenraads, Pieter-Jan; Schuttelaar, Marie-Louise A

    2017-02-01

    Cross-reactions and co-sensitizations are of great importance in understanding contact allergy and exposure sources. To investigate common cross-reactions and co-sensitizations in p-phenylenediamine (PPD)-sensitized and toluene-2,5-diamine (TDA)-sensitized individuals. From our patch test population, 8036 patients patch tested with the European baseline series were extracted. Readings had to be performed at least on day 3 according to ICDRG guidelines. Two hundred and fifty-one patients were sensitized to PPD and/or TDA; 231 patients were sensitized to PPD, and 109 to TDA. Significant differences were observed regarding the strengths of patch test reactions to PPD and number of cross-reactions. For TDA, a difference was found between all reaction strengths, except between + and ++ strengths. PPD-sensitized individuals were more likely to be sensitized to carba mix, cobalt chloride, colophonium, p-tert-butyl phenolformaldehyde resin, paraben mix, and methylisothiazolinone. TDA-sensitized individuals were more often sensitized to carba mix. Cross-reactivity was commonly found among individuals sensitized to PPD or TDA, and was strongly related to the strength of the patch test reaction. Regarding co-sensitizations, a frequently appearing or common exposure source could not be determined. However, modification of the allergen by, for example, the skin microbiota may have caused the formation of molecules that are, for the human immune system, indistinguishable from PPD. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Contact allergy to air-exposed geraniol: clinical observations and report of 14 cases.

    PubMed

    Hagvall, Lina; Karlberg, Ann-Therese; Christensson, Johanna Bråred

    2012-07-01

    The fragrance terpene geraniol forms sensitizing compounds via autoxidation and skin metabolism. Geranial and neral, the two isomers of citral, are the major haptens formed in both of these activation pathways. To investigate whether testing with oxidized geraniol detects more cases of contact allergy than testing with pure geraniol. The pattern of reactions to pure and oxidized geraniol, and metabolites/autoxidation products, was studied to investigate the importance of autoxidation or cutaneous metabolism in contact allergy to geraniol. Pure and oxidized geraniol were tested at 2.0% petrolatum in 2227 and 2179 consecutive patients, respectively. In parallel, geranial, neral and citral were tested in 2152, 1626 and 1055 consecutive patients, respectively. Pure and oxidized geraniol gave positive patch test reactions in 0.13% and 0.55% of the patients, respectively. Eight of 11 patients with positive patch test reactions to oxidized geraniol also reacted to citral or its components. Relevance for the positive patch test reactions in relation to the patients' dermatitis was found in 11 of 14 cases. Testing with oxidized geraniol could detect more cases of contact allergy to geraniol. The reaction pattern of the 14 cases presented indicates that both autoxidation and metabolism could be important in sensitization to geraniol. © 2012 John Wiley & Sons A/S.

  19. Patch test results in children and adolescents. Study from the Santa Casa de Belo Horizonte Dermatology Clinic, Brazil, from 2003 to 2010*

    PubMed Central

    Rodrigues, Dulcilea Ferraz; Goulart, Eugênio Marcos Andrade

    2015-01-01

    BACKGROUND Patch testing is an efficient method to identify the allergen responsible for allergic contact dermatitis. OBJECTIVE To evaluate the results of patch tests in children and adolescents comparing these two age groups' results. METHODS Cross-sectional study to assess patch test results of 125 children and adolescents aged 1-19 years, with suspected allergic contact dermatitis, in a dermatology clinic in Brazil. Two Brazilian standardized series were used. RESULTS Seventy four (59.2%) patients had "at least one positive reaction" to the patch test. Among these positive tests, 77.0% were deemed relevant. The most frequent allergens were nickel (36.8%), thimerosal (18.4%), tosylamide formaldehyde resin (6.8%), neomycin (6.4%), cobalt (4.0%) and fragrance mix I (4.0%). The most frequent positive tests came from adolescents (p=0.0014) and females (p=0.0002). There was no relevant statistical difference concerning contact sensitizations among patients with or without atopic history. However, there were significant differences regarding sensitization to nickel (p=0.029) and thimerosal (p=0.042) between the two age groups under study, while adolescents were the most affected. CONCLUSION Nickel and fragrances were the only positive (and relevant) allergens in children. Nickel and tosylamide formaldehyde resin were the most frequent and relevant allergens among adolescents. PMID:26560213

  20. Multicenter Patch Testing With Methylchloroisothizoline/Methylisothiazolinone in 100 and 200 ppm Within the International Contact Dermatitis Research Group.

    PubMed

    Engfeldt, Malin; Ale, Iris; Andersen, Klaus E; Elsner, Peter; Goh, Chee-Leok; Goossens, An; Jerajani, Hemangi; Matsunaga, Kayoko; Bruze, Magnus

    The preservative methylchloroisothiazolinone/methylisothiazolinone (MCI/MI) is a well-known contact sensitizer. Historically, there have been different opinions on the optimal patch test concentration of MCI/MI, and both 0.01% and 0.02% aqueous (aq.) have been proposed. In 2011, based on literature reviews, it was recommended that the concentration of 0.02% aq. should be used in the international baseline series. The aim of this study was to verify the recommendation from 2011 by comparing the patch test results from consecutive patch testing with MCI/MI 0.01% and 0.02% in clinics representing countries around the world. Two thousand seven hundred three consecutive patients with dermatitis in 8 dermatology clinics representing 8 countries were patch tested with MCI/MI 0.01% aq. and, in parallel with MCI/MI 0.02% aq., provisionally included in the baseline series. Contact allergy to MCI/MI at 0.01% and 0.02% was found in 3.7% and 5.6% of the patients, respectively (P < 0.001). Methylchloroisothiazolinone/MI 0.02% aq. (dose, 6 μg/cm) diagnoses significantly more contact allergy than 0.01% (dose, 3 μg/cm), without resulting in more adverse reactions. Methylchloroisothiazolinone/MI at 0.02% aq. should therefore be continuously used in the international baseline series.

  1. Patch testing with fragrance mix II: results of the IVDK 2005-2008.

    PubMed

    Krautheim, Andrea; Uter, Wolfgang; Frosch, Peter; Schnuch, Axel; Geier, Johannes

    2010-11-01

    The fragrance mix (FM I), established in 1977, detects the majority, but not all cases of contact allergy to fragrances. Based on European research 2002/2003, fragrance mix II (FM II) was developed to supplement FM I. In 2005, the German Contact Dermatitis Research Group (DKG) added FM II to their baseline series. To evaluate reactions to FM II and its constituents in routine patch testing. Retrospective data analysis of the Information Network of Departments of Dermatology (IVDK), 2005-2008, of patch test results with FM II and its constituents. A total of 35 633 patients were patch tested with FM II as part of the DKG baseline series. Of these, 1742 (4.9%) reacted positively. Concomitant reactions to FM I were observed in 41.9% of the patients reacting to FM II. In 367 FM II-positive patients, a full breakdown test of the mix was performed. Of these, 47.7% reacted to hydroxyisohexyl 3-cyclohexene carboxaldehyde, 16.1% to citral, 11.4% to farnesol, 3.8% to hexyl cinnamal, 2.7% to coumarin, and 2.5% to citronellol. FM II is an important screening and diagnostic tool to detect fragrance allergy. Hydroxyisohexyl 3-cyclohexene carboxaldehyde is the most important fragrance allergen in FM II. © 2010 John Wiley & Sons A/S.

  2. Frequency and trends of contact allergy to and iatrogenic contact dermatitis caused by topical drugs over a 25-year period.

    PubMed

    Gilissen, Liesbeth; Goossens, An

    2016-11-01

    Allergic contact dermatitis is the most common adverse reaction caused by topical drugs. To study the demographic characteristics and lesion locations of patients with iatrogenic dermatitis, and to analyse contact allergy to active principles and trends in frequencies over the years. Between 1990 and 2014, 14 911 patients were patch tested with the European baseline series. Patients with a presumed iatrogenic cause were often tested with a pharmaceutical series, and, if indicated, with photo-patch tests. Most were also tested with the topical products to which they had been exposed, along with their ingredients. Eight thousand three hundred and seventy-four (56%) patients tested positively, and 2600 (17.4%, 95%CI: 16.8-18.0%) of all patients suffered from iatrogenic contact dermatitis. The most important primary sites of dermatitis were the legs, face, and hands. The most common sensitizers included topical antibiotics, antiseptics, and corticosteroids. The most frequent baseline allergens in this subgroup were budesonide, neomycin, and benzocaine, although with a decreasing trend over the years. Many other allergens from different pharmacological classes were identified. With a prevalence of 17.4% of consecutive patients, iatrogenic contact dermatitis is a frequent diagnosis in patients attending a general patch test clinic, involving one-third of the patients with at least one positive reaction. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Contact reactions to fragrances.

    PubMed

    Katsarou, A; Armenaka, M; Kalogeromitros, D; Koufou, V; Georgala, S

    1999-05-01

    The most common reaction to fragrances is contact dermatitis, a delayed hypersensitivity reaction; however, other reactions include immediate contact reactions (contact urticaria) and photo-allergic reactions. Fragrance mix (FM) and balsam of Peru (BP) are used to screen for fragrance allergy. To study the different types of allergic skin reactions to fragrance compounds. Delayed hypersensitivity reactions to FM and BP were studied in 4,975 patients with suspected contact dermatitis by routine patch testing interpreted at 48 and 96 hours. In 664 of the patients, patch tests were read at 30 minutes to evaluate for immediate (wheal-and-flare) contact reactions and again at 48 and 96 hours. Photopatch tests to FM were performed in 111 patients with suspected photo-allergic dermatitis. Delayed contact reactions to FM occurred in 6.6% of females and 5.4% of males and to BP in 3.9% of females and 4.1% of males. Analysis of data over time (12 study years) showed an increased trend for reactions to fragrances, particularly in males. Sensitivity to other contact allergens (polysensitivity) was found in 62% of patients and polysensitivity presented more often with generalized contact dermatitis. The most sensitizing components of the fragrance mix that were tested in 38 patients were cinnamic alcohol, oak moss, and cinnamic aldehyde. There were 112 immediate patch test reactions to FM and 113 to BP in 664 patients. Immediate contact reactions were followed by delayed contact reactions in 13.4% of patients for FM and 8.8% for BP, representing a significant increase in the frequency of delayed contact reactions. Patients with immediate contact reactions to fragrances did not have a higher incidence of atopy (25.9%). No cases of positive photopatch test reactions to FM were seen. Fragrances commonly cause both delayed and immediate patch test reactions and patients with immediate contact reactions have an increase in delayed contact reactions to the same allergen.

  4. Rosacea and contact allergy to cosmetics and topical medicaments--retrospective analysis of multicentre surveillance data 1995-2002.

    PubMed

    Jappe, U; Schnuch, A; Uter, W

    2005-02-01

    The role of contact allergy in rosacea has rarely been investigated. In this retrospective study, 361 out of 76,697 patients tested and documented by the Information Network of Departments of Dermatology between 1995 and 2002 had rosacea. Patch tests included standard series and constituents of cosmetics and topical medicaments. 118/361 had additionally been patch tested with their own cosmetics/medicaments. Positive reactions occurred to nickel (II) sulfate in 9.3%, fragrance mix in 8.8%, thimerosal in 6.9%, Myroxylon pereirae resin in 5.9%, potassium dichromate in 4.6% and propolis in 2.8%. Whereas rosacea patients had a significantly higher risk of contact allergy to propolis compared to the remaining patients, in an age- and sex-adjusted analysis, contact allergy to nickel was significantly less frequent in this group. For Lyral, the risk was elevated, albeit not significantly. Only 2/329 patients were positive to neomycin sulfate and 1/100 to gentamicin sulfate, among the panel of (topical) antibiotics tested. Among 118 patients tested with their own products, 3 were tested to metronidazole, 1 reacting positively. Irritant or doubtful patch test reactions were provoked by various substances (vehicles, oxidants and preservatives of various creams), which might also be clinically important, considering the heightened sensitivity of rosaceous skin.

  5. North American Contact Dermatitis Group patch test results: 2009 to 2010.

    PubMed

    Warshaw, Erin M; Belsito, Donald V; Taylor, James S; Sasseville, Denis; DeKoven, Joel G; Zirwas, Matthew J; Fransway, Anthony F; Mathias, C G Toby; Zug, Kathryn A; DeLeo, Vincent A; Fowler, Joseph F; Marks, James G; Pratt, Melanie D; Storrs, Frances J; Maibach, Howard I

    2013-01-01

    Patch testing is an important diagnostic tool for determination of substances responsible for allergic contact dermatitis. This study reports the North American Contact Dermatitis Group (NACDG) patch testing results from January 1, 2009, to December 31, 2010. At 12 centers in North America, patients were tested in a standardized manner with a screening series of 70 allergens. Data were manually verified and entered into a central database. Descriptive frequencies were calculated, and trends were analyzed using χ2 statistics. A total of 4308 patients were tested. Of these, 2614 (60.7%) had at least 1 positive reaction, and 2284 (46.3%) were ultimately determined to have a primary diagnosis of allergic contact dermatitis. Four hundred twenty-seven (9.9%) patients had occupationally related skin disease. There were 6855 positive allergic reactions. As compared with the previous reporting period (2007-2008), the positive reaction rates statistically decreased for 20 allergens (nickel, neomycin, Myroxylon pereirae, cobalt, formaldehyde, quaternium 15, methydibromoglutaronitrile/phenoxyethanol, methylchlorisothiazolinone/methylisothiazolinone, potassium dichromate, diazolidinyl urea, propolis, dimethylol dimethylhydantoin, 2-bromo-2-nitro-1,3-propanediol, methyl methacrylate, ethyl acrylate, glyceryl thioglycolate, dibucaine, amidoamine, clobetasol, and dimethyloldihydroxyethyleneurea; P < 0.05) and statistically increased for 4 allergens (fragrance mix II, iodopropynyl butylcarbamate, propylene glycol, and benzocaine; P < 0.05). Approximately one quarter of tested patients had at least 1 relevant allergic reaction to a non-NACDG allergen. Hypothetically, approximately one quarter of reactions detected by NACDG allergens would have been missed by TRUE TEST (SmartPractice Denmark, Hillerød, Denmark). These results affirm the value of patch testing with many allergens.

  6. Allergic contact dermatitis pattern in Kuwait: nickel leads the pack. In-depth analysis of nickel allergy based on the results from a large prospective patch test series report

    PubMed Central

    Almutawa, Fahad

    2017-01-01

    Introduction Contact dermatitis is a relatively common dermatosis reported among several population groups from all around the globe. However, the data from Kuwait is unavailable. Patch tests are essential for the diagnosis of contact sensitization. Aim To determine a relative frequency and pattern of sensitizers to different allergens in patients of suspected contact dermatitis in Kuwait and, also to study the role of the commonest sensitizer in detail. Material and methods Patch tests were performed in 2461 consecutive patients with a clinical diagnosis of contact dermatitis seen at our hospital between September 1, 2014 and August 31, 2015. Out of the total of 1381 (56.1%) patients with positive patch test results to at least one allergen, 546 (22.2%) patients with a single positive reaction to nickel only (single largest sensitizer) were selected as the study population for further detailed analysis. Results At least one positive patch test reaction was found in 1381 (56.12%) patients. Nickel was found to be the most common sensitizer seen in 546 (40%) patients. The mean age was 37.3 ±13.8 years and the mean duration of disease was 27.3 ±13.8 months. Most (387/546) patients sensitized were females. The forearms/hands and wrists were the most prevalent sites (52.56% of the participants). In 58.91% of women, dermatitis was more often confined to other sites, mostly ears and the neck due to earrings and necklaces. Just more than half of the number (51.09%) of nickel allergic patients were found in the age group of 15–25 years. Hairdressers/beauticians were the most affected group followed by house workers (housewives, cleaners, housekeepers). Conclusions Nickel is the single most common sensitizer found in our patients, and female sex, young age, occupation with long hours of contact to nickel are high risk factors. We recommend that a directive, which limits the release of nickel from products with extended skin contact, be approved in Kuwait. PMID:28670248

  7. Sensitization to fragrance materials in Indonesian cosmetics.

    PubMed

    Roesyanto-Mahadi, I D; Geursen-Reitsma, A M; van Joost, T; van den Akker, T W

    1990-04-01

    2 different groups of patients were patch tested with 2 test series (A and B) containing extracts of fragrance raw materials, traditionally used in Indonesian cosmetics. Series A consisted of diluted extracts of commercially available Indonesian fragrances. Series B consisted of extracts prepared in our department from corresponding indigenous flowers and fruits. Group 1 consisted of 32 patients positive to fragrance-mix, of whom 8 (25%) had positive tests to 1 or more of the different extracts of fragrance raw materials. Reactions were observed to extracts of: Rosa hybrida Hort (7); Canangium odoratum Baill (5); Citrus aurantifolia Swingle (4); Jasminum sambac Ait (2). 6 of the 8 patients had reactions to 1 or more of the components of fragrance-mix: oakmoss (3); cinnamic alcohol (2), isoeugenol (1); cinnamic aldehyde (1) and geraniol (1). Group 2 consisted of 159 patients patch tested on suspicion of contact dermatitis, who were fragrance-mix negative. Only 2 (1.2%) had a positive patch test to the extracts of fragrance raw materials. Specimens taken (as is) from the flowers and citrus fruits (being the basis sources of the fragrance raw materials) were less antigenic. The use of additional test series in Indonesia to detect allergy to traditional cosmetics and perfumes merits further investigation.

  8. Hydroxyisohexyl 3-cyclohexene carboxaldehyde (Lyral®) as allergen: experience from a contact dermatitis unit.

    PubMed

    Carvalho, Rodrigo; Maio, Paula; Amaro, Cristina; Santos, Raquel; Cardoso, Jorge

    2011-09-01

    Hydroxyisohexyl 3-cyclohexene carboxaldehyde (HICC)-Lyral® is a widely used synthetic fragrance found in personal care and household products. It is an aldehyde, lipophilic enough to penetrate the skin and is a frequent cause of contact sensitization. Describe the frequency of contact allergy to HICC in a Contact Dermatitis Unit, after its inclusion in baseline patch test series. A retrospective study including all patients submitted to patch test, from January 2007 to December 2009. Over a 3-year period, 629 consecutive patients were patch tested. The frequency of positive reactions to HICC was 2.7% (17/629). Of the positive patients, 35% (6/17) gave a history of atopy, 58.8% (10/17) had eczema on the face and neck, 23.5% (4/17) on the hands, 23.5% (4/17) in the axillae, 17.6% (3/17) on the trunk and 6% (3/17) had generalized eczema. All patients were patch positive for more than one allergen: all (17/17) positive to fragrance Mix 2 (FM2); 47% of the patients (8/17) positive to fragrance Mix 1 (FM1); and 23.5% of the patients (4/17) positive to Balsam of Peru. In 94% (16/17) of cases, the reaction was judged to be of current relevance. The frequency of positive reactions to HICC of 2.7% found in our population is according to what is described in several European reports, where HICC is still widely used as a fragrance ingredient. In contrast, in North America, the prevalence is lower. All the patients were positive also to FM2. The association found between reactions to FM1 and HICC is also commonly reported and could represent a concomitant sensitization following increased exposure to fragrance allergens. These data confirm the importance of HICC introduction in the baseline patch test series.

  9. Contact allergy to essential oils: current patch test results (2000-2008) from the Information Network of Departments of Dermatology (IVDK).

    PubMed

    Uter, Wolfgang; Schmidt, Erich; Geier, Johannes; Lessmann, Holger; Schnuch, Axel; Frosch, Peter

    2010-11-01

    Essential oils are used in perfumery and in products for aromatherapy or balneotherapy. Previous studies have shown some to be important contact sensitizers. A practical diagnostic approach, based on the results of a large, central European network and other evidence, is needed. Data of the Information Network of Departments of Dermatology (IVDK; www.ivdk.org) on all patients patch tested between January 2000 and December 2008 with essential oils were retrospectively analysed. 15 682 patients of 84 716 consulting in the period had been tested with at least one essential oil, and 637 reacted positively to at least one of the essential oils, most commonly to ylang-ylang oil (I and II) (3.1% as weighted mean of positive tests in special series and consecutive testing), lemongrass oil (1.8%), jasmine absolute (1.6%), sandalwood oil and clove oil (1.5% each). Cross-reactivity between distillate and main allergen, if available, was marked. Patch testing the important essential oils should be considered in patients with a suggestive history. Additionally, culprit products brought in by the patient should be tested, closing a diagnostic gap by (i) including those other essential oils not included in the commercial test series and (ii) providing a means of testing with the oxidized substances to which the patient had actually been exposed. © 2010 John Wiley & Sons A/S.

  10. Conctact dermatitis: some important topics.

    PubMed

    Pigatto, P D

    2015-11-01

    Allergic contact dermatitis (ACD) is a type IV delayed hypersensitivity reaction. The gold standard for diagnosis is patch testing. The prevalence of positive patch tests in referred patients with suspected ACD ranges from 27 to 95.6%. The relationship between ACD and atopic dermatitis (AD) is complicated with conflicting reports of prevalence in the literature; however, in a patient with dermatitis not responding to traditional therapies, or with new areas of involvement, ACD should be considered as part of the work-up.

  11. Contact allergy to denture materials in the burning mouth syndrome.

    PubMed

    van Joost, T; van Ulsen, J; van Loon, L A

    1988-02-01

    Several factors may be responsible for stomatitis in general and the burning mouth syndrome in particular. The results of patch testing are reported in 4 patients with burning mouth symptoms thought to be due to sensitization to denture material. 2 patients reacted to substances in Luxene dentures, but the allergens were not identified. In a 3rd patient, sensitization was found to monomeric methyl methacrylate. The other patient gave positive patch tests to epoxy resin (and bisphenol A), probably present in glue used for repair of dental plates. To obtain a complete diagnosis in cases of suspected contact stomatitis due to allergens in dentures, a reliable standard test series is required.

  12. EAACI position paper for practical patch testing in allergic contact dermatitis in children.

    PubMed

    de Waard-van der Spek, Flora B; Darsow, Ulf; Mortz, Charlotte G; Orton, David; Worm, Margitta; Muraro, Antonella; Schmid-Grendelmeier, Peter; Grimalt, Ramon; Spiewak, Radoslaw; Rudzeviciene, Odilija; Flohr, Carsten; Halken, Susanne; Fiocchi, Alessandro; Borrego, Luis Miguel; Oranje, Arnold P

    2015-11-01

    Allergic contact dermatitis (ACD) in children appears to be on the increase, and contact sensitization may already begin in infancy. The diagnosis of contact dermatitis requires a careful evaluation of a patient's clinical history, physical examination, and skin testing. Patch testing is the gold standard diagnostic test. Based on consensus, the EAACI Task Force on Allergic Contact Dermatitis in Children produced this document to provide details on clinical aspects, the standardization of patch test methodology, and suggestions for future research in the field. We provide a baseline list of test allergens to be tested in children with suspected ACD. Additional tests should be performed only on specific indications. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. A rivastigmine patch for the treatment of Alzheimer's disease and Parkinson's disease dementia.

    PubMed

    Cummings, Jeffrey; Winblad, Bengt

    2007-11-01

    Rivastigmine patch is the first transdermal treatment to be approved for Alzheimer's disease (AD) and Parkinson's disease dementia in the USA and for AD in Europe. It provides smooth, continuous drug delivery, and has the potential to maintain rivastigmine concentrations within an optimal therapeutic window while avoiding the peaks and troughs associated with oral drug delivery. The target dose, rivastigmine 9.5 mg/24 h patch (a 10 cm(2) patch), is given once daily and requires a simple one-step dose titration to the therapeutic dose. In a 24-week study in 1195 AD patients, the rivastigmine 9.5 mg/24 h patch provided similar efficacy to the highest dose range of capsules, with approximately three-times fewer reports of nausea and vomiting. Patients in the 9.5 mg/24 h patch and 12 mg/day capsule groups evidenced significant improvements versus placebo on both primary outcome measures: the Alzheimer's Disease Assessment Scale-Cognitive subscale; and Alzheimer's Disease Cooperative Study-Clinical Global Impression of Change; in addition to the following secondary outcome measures: Alzheimer's Disease Cooperative Study-Activities of Daily Living scale; Mini-Mental State Examination; and Trail Making Test Part A for assessment of attention, visual tracking and motor processing speed. Treatment differences on the Neuropsychiatric Inventory and Ten Point Clock-drawing Test did not reach statistical significance in this study. The patch may be the optimal way to treat dementia patients with rivastigmine.

  14. Burning mouth syndrome: the role of contact hypersensitivity.

    PubMed

    Marino, R; Capaccio, P; Pignataro, L; Spadari, F

    2009-05-01

    Burning mouth syndrome is a burning sensation or stinging disorder affecting the oral mucosa in the absence of any clinical signs or mucosal lesions. Some studies have suggested that burning mouth syndrome could be caused by the metals used in dental prostheses, as well as by acrylate monomers, additives and flavouring agents, although others have not found any aetiologic role for hypersensitivity to dental materials. To evaluate the extent and severity of adverse reactions to dental materials in a group of patients with burning mouth syndrome, and investigate the possible role of contact allergy in its pathogenesis. We prospectively studied 124 consecutive patients with burning mouth syndrome (108 males; mean age 57 years, range 41-83), all of whom underwent allergen patch testing between 2004 and 2007. Sixteen patients (13%) showed positive patch test reactions and were classified as having burning mouth syndrome type 3 or secondary burning mouth syndrome (Lamey's and Scala's classifications). Although we did not find any significant association between the patients and positive patch test reactions, it would be advisable to include hypersensitivity to dental components when evaluating patients experiencing intermittent oral burning without any clinical signs.

  15. Contact urticaria from nickel and plastic additives (butylhydroxytoluene, oleylamide).

    PubMed

    Osmundsen, P E

    1980-12-01

    In two patients urticaria was elicited by contact with nickel-containing objects. Chamber-prick test with nickel sulfate 2.5% in pet. evoked a strong urticarial reaction in both patients. In one of the patients contact with plastic articles also provoked urticaria. A 20-min patch test with several articles of plastic (polyethylene and PVC) and with butylhydroxytoluene (BHT) 1% in ethanol elicited urticarial reactions. BHT is used as an antioxidant in plastic. Furthermore, open patch test with oleylamide (amide of oleic acid) 0.1% in ethanol elicited a strong urticarial reaction in 20 min. This chemical is used as a slipping agent in plastic.

  16. Solvent Orange 60 is a potent contact sensitizer in occupational and everyday life.

    PubMed

    Linauskienė, Kotryna; Zimerson, Erik; Antelmi, Annarita; Bruze, Magnus; Hagvall, Lina; Hamnerius, Nils; Hauksson, Inese; Ryberg, Kristina; Isaksson, Marléne

    2018-05-30

    Solvent Orange (SO) 60 is a perinone-type dye that is often used in plastic materials such as spectacle frames and has been shown to cause contact allergy. The first case of SO 60 allergic contact dermatitis caused by spectacle frames was reported in 1999, and the second in 2011. We have recently seen 10 patients, of whom 6 developed dermatitis in the retroauricular/temporal area after wearing plastic spectacles. To report the cause of the dermatitis in the 10 patients and to describe our first case with occupational SO 60 contact allergy. In this retrospective study, patch test results of 10 patients, tested with the Swedish baseline series and our specific spectacle and/or plastic series, including SO 60 1.0% pet., in 2011-2017, were analysed and compared with data published earlier. Ten patients, 2 males and 8 females, aged 43 to 71 years, reacted positively to SO 60 1.0% pet., namely, 4 pensioners, 2 nurses, 1 office worker, 1 teacher, 1 shop assistant, and 1 unemployed person. Four of the patients had an atopic history. Patch test reactions varied from + to +++; some had spread >20 cm outside the test area, and consisted of erythematous, infiltrated skin with papules. Retesting of patient no. 1 with serial dilutions of SO 60 in acetone to pinpoint his level of reactivity showed positive reactions down to 1 ppm. Three patients reacted to the extracts of their earpieces. Gas chromatography-mass spectrometry was used to confirm the presence of SO 60 in 2 earpieces. SO 60 should be included in any spectacle patch test series that may be used. If there is a strong suspicion of contact allergy to SO 60 before patch testing, lowering the test concentration from 1.0% to 0.01% should be considered. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Occupational contact dermatitis caused by aniline epoxy resins in the aircraft industry.

    PubMed

    Pesonen, Maria; Suuronen, Katri; Jolanki, Riitta; Aalto-Korte, Kristiina; Kuuliala, Outi; Henriks-Eckerman, Maj-Len; Valtanen, Ilona; Alanko, Kristiina

    2015-08-01

    Tetraglycidyl-4,4'-methylenedianiline (TGMDA) is an aniline epoxy resin used in, for example, resin systems of pre-impregnated composite materials (prepregs) of the aircraft industry. Allergic contact dermatitis caused by TGMDA in prepregs has been described previously. To report on 9 patients with occupational allergic contact dermatitis caused by TGMDA in epoxy glues used in helicopter assembly. The patients were examined with patch testing at the Finnish Institute of Occupational Health in 2004-2009. The first patient was diagnosed by testing both components of two epoxy glues from the workplace, and was also tested with glue ingredients, including TGMDA. The following patients were tested with the glues and TGMDA. The resin parts of the glues were analysed for their epoxy compounds, including TGMDA. All of the patients had a patch test reaction to one or both of the resin parts of the TGMDA-containing glues. Eight of them had a strong allergic reaction to TGMDA, and one had a doubtful reaction to TGMDA. Two of the patients also had an allergic reaction to triglycidyl-p-aminophenol (TGPAP), another aniline epoxy resin, which was not present in the TGMDA-containing glues. In aircraft industry workers with suspected occupational dermatitis, aniline epoxy resins should be considered and patch tested as possible contact allergens. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. The Evaluation of Contact Sensitivity with Standard and Cosmetic Patch Test Series in Rosacea Patients

    PubMed Central

    Bulur, Isil; Saracoglu, Zeynep Nurhan; Bilgin, Muzaffer

    2018-01-01

    Background Rosacea is a common dermatosis characterized by erythema, telangiectasia, papules and pustules. Objective We aimed to evaluate contact sensitivity in the rosacea patients. Methods We included 65 rosacea patients and 60 healthy volunteers in the study. The patient and control groups were patch tested with European baseline series and cosmetic series. Results A positive reaction to at least 1 allergen in the European standard series was found in 32.3% of rosacea patients and 20.0% of subjects in the control group while the relevant numbers were 30.8% of rosacea patients and 10% of controls with the cosmetic series (p=0.08). In total, we found a positive reaction to at least 1 allergen in 38.5% of patients and 25.0% of controls (p=0.15). We did not find a statistically significant relationship between a positive reaction to 1 allergen in total and the gender, skin type, rosacea type, ocular involvement, age and disease duration. There were more symptoms in patients with a positive reaction to allergens (p<0.001). Conclusion Contact sensitivity was detected more common in rosacea patients. Patch testing may be useful in the treatment and follow up of rosacea patients especially if symptoms such as itching, burning and stinging are present. PMID:29853742

  19. The Evaluation of Contact Sensitivity with Standard and Cosmetic Patch Test Series in Rosacea Patients.

    PubMed

    Erdogan, Hilal Kaya; Bulur, Isil; Saracoglu, Zeynep Nurhan; Bilgin, Muzaffer

    2018-06-01

    Rosacea is a common dermatosis characterized by erythema, telangiectasia, papules and pustules. We aimed to evaluate contact sensitivity in the rosacea patients. We included 65 rosacea patients and 60 healthy volunteers in the study. The patient and control groups were patch tested with European baseline series and cosmetic series. A positive reaction to at least 1 allergen in the European standard series was found in 32.3% of rosacea patients and 20.0% of subjects in the control group while the relevant numbers were 30.8% of rosacea patients and 10% of controls with the cosmetic series ( p =0.08). In total, we found a positive reaction to at least 1 allergen in 38.5% of patients and 25.0% of controls ( p =0.15). We did not find a statistically significant relationship between a positive reaction to 1 allergen in total and the gender, skin type, rosacea type, ocular involvement, age and disease duration. There were more symptoms in patients with a positive reaction to allergens ( p <0.001). Contact sensitivity was detected more common in rosacea patients. Patch testing may be useful in the treatment and follow up of rosacea patients especially if symptoms such as itching, burning and stinging are present.

  20. Terra Firma-Forme Dermatosis in Singaporean Patients: The "Alcohol Wipe" Sign.

    PubMed

    Oh, Choon Chiat; Oon, Hazel H; Ng, See Ket; Tee, Shang Ian; Jhingan, Anjali; Chong, Wei-Sheng

    2016-01-01

    The term terra firma-forme dermatosis arises from the Latin phrase terra firma , meaning dry land (dirt), thus implying dirt-like dermatosis. The authors highlight five cases of patients with terra firma-forme dermatosis presenting to our dermatology center between 2012 and 2013. All patients presented to the dermatologist for persistent reticulated brown patches on the skin. These patients ranged in age from 6 to 22 years. All patients had tried various cleansing soaps and agents but were unable to remove the patches. The condition was cosmetically unacceptable to the patients and parents. Clinically, these patients had reticulated brown patches. Rubbing 70% isopropyl alcohol wipes on the affected areas demonstrated clearance of the brown pigmented patches in all cases. The diagnosis of terra firma-forme dermatosis (TFFD) was confirmed by forceful rubbing with a gauze pad immersed in 70% isopropyl alcohol or ethyl alcohol. Patients should be reassured about the benign nature of TFFD and educated about the cleaning procedure. Recognition of this condition can assist physicians in making a diagnosis and therapy with a simple alcohol wipe, preventing further unnecessary tests for patients.

  1. Patch test reactivity to metal allergens following regulatory interventions: a 33-year retrospective study.

    PubMed

    Thyssen, Jacob Pontoppidan; Ross-Hansen, Katrine; Menné, Torkil; Johansen, Jeanne Duus

    2010-08-01

    Contact allergy epidemics to chromate and nickel were addressed in Denmark in 1983 and 1990 by regulatory interventions. To evaluate whether regulatory interventions on nickel and chromate exposure have reduced the proportion of strong patch test reactions. 22 506 patients with dermatitis aged 4-99 years were patch tested with nickel sulfate, potassium dichromate, or cobalt chloride between 1977 and 2009. The proportion of 3+ reactions to nickel sulfate was reduced and almost disappeared after the mid- and late 1980s (P-trend = 0.001). Today, 1+ and 2+ nickel reactions occur equally frequent. Cobalt chloride patch test reactivity reflected the nickel development to some degree. The proportion of 3+ reactions to potassium dichromate was reduced during the 1980s (P-trend = 0.13), whereas the proportion of 2+ reactions to potassium dichromate have increased in recent years. The decrease in nickel sulfate and cobalt chloride 3+ patch test reactivity began long before the Danish nickel regulation came into effect. This could be because of research activity at the time as well as political attention in Northern Europe. The chromate content in cement regulation may have changed the epidemiology of patch test reactivity; however, in recent years, 2+ reactions to chromate have increased markedly, a development that should be carefully followed.

  2. Multicenter Patch Testing With Methylisothiazolinone and Methylchloroisothiazolinone/Methylisothiazolinone Within the International Contact Dermatitis Research Group.

    PubMed

    Isaksson, Marléne; Ale, Iris; Andersen, Klaus E; Elsner, Peter; Goh, Chee-Leok; Goossens, An; Jerajani, Hemangi; Matsunaga, Kayoko; McFadden, John; Bruze, Magnus

    The preservatives methylchloroisothiazolinone/methylisothiazolinone (MCI/MI) and MI are well-known contact sensitizers. Recently, an increase in the contact allergy frequency for MI 0.2% aqueous (aq) has been seen in many European countries paralleled with an increase in MCI/MI allergy. Many of the MI-allergic patients do not react to MCI/MI 0.01% or 0.02% because the concentration of MI in these preparations is too low (25 and 50 ppm, respectively) to elicit a positive patch test reaction. The aims of this study were to investigate the prevalence of contact allergy to MI in the participating clinics representing various countries all over the world, to assess how many additional individuals with contact allergy are found by testing MI 0.2% aq in parallel with MCI/MI 0.02%, and to assess the clinical relevance of MI and MCI/MI allergies. In 9 dermatology clinics representing 9 countries, 3865 consecutive patients with dermatitis were patch tested with MI 0.2% aq and in parallel with MCI/MI 0.02% aq, provisionally included into the baseline series. An assessment of clinical relevance in those allergic to MI was also made. Contact allergy to MI was found in 284 patients (7.3%). The frequency of contact allergy varied from 0.8% to 10.9% in different centers. Simultaneous reactivity to 200 ppm of MCI/MI was found in 67.3% of the MI-positive patients. Contact allergy to MI alone without any simultaneous contact allergy to 200 ppm of MCI/MI was diagnosed in 93 patients (32.7%; 2.4% of all tested patients). The contact allergy to MI and/or MCI/MI could explain or contribute to dermatitis in more than 60% of the MI-allergic patients. Methylisothiazolinone of 2000 ppm needs to be patch tested on its own to not miss contact allergy.

  3. Hair dye dermatitis and p-phenylenediamine contact sensitivity: A preliminary report

    PubMed Central

    Gupta, Mrinal; Mahajan, Vikram K.; Mehta, Karaninder S.; Chauhan, Pushpinder S.

    2015-01-01

    Background: The contact allergic reactions from p-phenylenediamine (PPD) in hair dyes vary from mild contact dermatitis to severe life- threatening events (angioedema, bronchospasm, asthma, renal impairment). Objectives: To study the clinical patterns and PPD contact sensitivity in patients with hair-dye dermatitis. Materials and Methods: Eighty (M:F 47:33) consecutive patients aged between 18 and 74 years suspected to have contact allergy from hair dye were studied by patch testing with Indian Standard Series including p-phenylenediamine (PPD, 1.0% pet). Results: 54 Fifty-four (M:F 21:33) patients showed positive patch tests from PPD. Eight of these patients also showed positive patch test reaction from fragrance mix, thiuram mix, paraben mix, or colophony. Fifty-seven (71%) patients affected were aged older than 40 years. The duration of dermatitis varied from < 1 month to > 1 year with exacerbation following hair coloring. Forty-nine patients had dermatitis of scalp and/or scalp margins and 23 patients had face and neck dermatitis. Periorbital dermatitis, chronic actinic dermatitis, and erythema multiforme-like lesions were seen in 4, 2, and 1 patients, respectively. Conclusions: Hair dyes and PPD constitute a significant cause of contact dermatitis. There is an urgent need for creating consumer awareness regarding hair-dyes contact sensitivity and the significance of performing sensitivity testing prior to actual use. PMID:26225326

  4. Allergy to oxidized limonene and linalool is frequent in the U.K.

    PubMed

    Audrain, H; Kenward, C; Lovell, C R; Green, C; Ormerod, A D; Sansom, J; Chowdhury, M M U; Cooper, S M; Johnston, G A; Wilkinson, M; King, C; Stone, N; Horne, H L; Holden, C R; Wakelin, S; Buckley, D A

    2014-08-01

    The oxidized forms of the fragrance terpenes limonene and linalool are known to cause allergic contact dermatitis. Significant rates of contact allergy to these fragrances have been reported in European studies and in a recent worldwide study. Patch testing to oxidized terpenes is not routinely carried out either in the U.K. or in other centres internationally. To investigate the prevalence of contact allergy to oxidized limonene and linalool in the U.K. Between 1 August 2011 and 31 December 2012, 4731 consecutive patients in 13 U.K. dermatology departments were tested for hydroperoxides of limonene 0·3% pet., hydroperoxides of linalool 1·0% pet., stabilized limonene 10·0% pet. and stabilized linalool 10·0% pet. Doubtful (?+) and equivocal (±) reactions were grouped together as irritant reactions. Two hundred and thirty-seven patients (5·0%) had a positive patch test reaction to hydroperoxides of limonene 0·3% pet. and 281 (5·9%) to hydroperoxides of linalool 1·0% pet. Irritant reactions to one or both oxidized terpenes were found in 242 patients (7·3%). Eleven patients (0·2%) had a positive patch test reaction to the stabilized terpenes alone. This large, multicentre U.K. audit shows a significant rate of allergy to the hydroperoxides of limonene and linalool plus a high rate of irritant reactions. Testing to the oxidized forms alone captures the majority (97·0%; 411 of 422) of positive reactions; testing to nonoxidized terpenes appears to be less useful. We recommend that the hydroperoxides of limonene and linalool be added to an extended baseline patch test series. © 2014 British Association of Dermatologists.

  5. Positive relationship-intensity of response to p-phenylenediamine on patch testing and cross-reactions with related allergens.

    PubMed

    Thomas, Bjorn R; White, Ian R; McFadden, John P; Banerjee, Piu

    2014-08-01

    Hair dye exposure is the most common cause of sensitization to p-phenylenediamine (PPD). Cross-reactions with structurally related allergens occur. It is suggested that a stronger patch test reaction (3+ rather than 1+) to PPD (usually tested as 1% petrolatum) is associated with an increased propensity for cross-reactions. In this article we will demonstrate this association. Of 230 patients with allergic reactions to PPD on patch testing identified during 2007-2012 from clinical records, notes for 221 were available for review. Data were collected regarding age, sex, and grade of reaction [International Contact Dermatitis Research Group (ICDRG) criteria] to PPD. Cross-reactions with the following allergens, found in our baseline series, were recorded: Disperse Yellow 3, N-isopropyl-N'-phenyl-p-phenylenediamine (IPPD), and caine mix. Having excluded 23 doubtful reactions, the reactions from 198 patients were further considered. Of the patients, 75.3% (n = 149) were female, and the mean age was 48.6 years (12-82 years). Of the patients allergic to PPD, 16.6% (n = 33) showed cross-reactions with one or more related allergens. Cross-reactions were seen in 16% with a grade of 1+, 14.5% with a grade of 2+, 28.6% with a grade of 3+ when PPD was tested 1% pet., and 50.0% when PPD was tested at 0.1-0.001%, arbitrarily considered to be 4+ (p = 0.02; Cramér's V = 0.23). An increasing likelihood of reactions to Disperse Yellow 3, IPPD or caine mix was seen with increasing strength of patch test reaction to PPD. The clinical relevance of these cross-reactions is unclear. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Monitoring cocaine use in substance-abuse-treatment patients by sweat and urine testing.

    PubMed

    Preston, K L; Huestis, M A; Wong, C J; Umbricht, A; Goldberger, B A; Cone, E J

    1999-09-01

    Sweat and urine specimens were collected from 44 methadone-maintenance patients to evaluate the use of sweat testing to monitor cocaine use. Paired sweat patches that were applied and removed weekly (on Tuesdays) were compared with 3-5 consecutive urine specimens collected Mondays, Wednesdays, and Fridays. All patches (N = 930) were extracted in 2.5 mL of solvent and analyzed by ELISA immunoassay (cutoff concentration 10 ng/mL); a subset of patches (N = 591) was also analyzed by gas chromatography-mass spectrometry (GC-MS) for cocaine, benzoylecgonine (BZE), and ecgonine methyl ester (EME) (cutoff concentration 5 ng/mL). Urine specimens were subjected to qualitative analysis by EMIT (cutoff 300 ng/mL) and subsets were analyzed by TDx (semiquantitative, LOD 30 ng/mL) and by GC-MS for cocaine (LOD 5 ng/mL). Results were evaluated to (1) determine the relative amounts of cocaine and its metabolites in sweat; (2) assess replicability in duplicate patches; (3) compare ELISA and GC-MS results for cocaine in sweat; and (4) compare the detection of cocaine use by sweat and urine testing. Cocaine was detected by GC-MS in 99% of ELISA-positive sweat patches; median concentrations of cocaine, BZE, and EME were 378, 78.7, and 74 ng/mL, respectively. Agreement in duplicate patches was approximately 90% by ELISA analysis. The sensitivity, specificity, and efficiency of sweat ELISA cocaine results as compared with sweat GC-MS results were 93.6%, 91.3%, and 93.2%, respectively. The sensitivity, specificity, and efficiency between ELISA sweat patch and EMIT urine results were 97.6%, 60.5%, and 77.7%, respectively. These results support the use of sweat patches for monitoring cocaine use, though further evaluation is needed.

  7. Patch testing to a textile dye mix by the international contact dermatitis research group.

    PubMed

    Isaksson, Marléne; Ale, Iris; Andersen, Klaus E; Diepgen, Thomas; Goh, Chee-Leok; Goossens R, An; Jerajani, Hemangi; Maibach, Howard I; Sasseville, Denis; Bruze, Magnus

    2015-01-01

    Disperse dyes are well-known contact sensitizers not included in the majority of commercially available baseline series. To investigate the outcome of patch testing to a textile dye mix (TDM) consisting of 8 disperse dyes. Two thousand four hundred ninety-three consecutive dermatitis patients in 9 dermatology clinics were patch tested with a TDM 6.6%, consisting of Disperse (D) Blue 35, D Yellow 3, D Orange 1 and 3, D Red 1 and 17, all 1.0% each, and D Blue 106 and D Blue 124, each 0.3%. 90 reacted positively to the TDM. About 92.2% of the patients allergic to the TDM were also tested with the 8 separate dyes. Contact allergy to TDM was found in 3.6% (1.3-18.2) Simultaneous reactivity to p-phenylenediamine was found in 61.1% of the TDM-positive patients. Contact allergy to TDM and not to other p-amino-substituted sensitizers was diagnosed in 1.2%. The most frequent dye allergen in the TDM-positive patients was D Orange 3. Over 30% of the TDM allergic patients had been missed if only the international baseline series was tested. Contact allergy to TDM could explain or contribute to dermatitis in over 20% of the patients. Textile dye mix should be considered for inclusion into the international baseline series.

  8. Cinnamic aldehyde: a survey of consumer patch-test sensitization.

    PubMed

    Danneman, P J; Booman, K A; Dorsky, J; Kohrman, K A; Rothenstein, A S; Sedlak, R I; Steltenkamp, R J; Thompson, G R

    1983-12-01

    The potential for cinnamic aldehyde, an important fragrance and flavour ingredient, to induce or to elicit delayed contact hypersensitivity reactions in man was evaluated by analysing patch-test data. Results of studies involving a total of 4117 patch tests on various consumer products and fragrance blends containing cinnamic aldehyde and on the material itself were collected from fragrance and formulator companies. The data indicate that cinnamic aldehyde contained in consumer products and fragrance blends at concentrations up to 6 X 10(-1)%, and patch-tested at concentrations up to 8 X 10(-3)%, has no detectable potential to induce hypersensitivity. Cinnamic aldehyde when tested alone induced a dose-related hypersensitivity response. According to published reports, cinnamic aldehyde elicited positive delayed hypersensitivity responses in dermatitic patients. However, results of the current survey show that when cinnamic aldehyde was tested alone or as part of a mixture in subjects in the general population, no pre-existing hypersensitivity reactions to the fragrance material were observed in any of the 4117 patch tests which constituted the survey. Cinnamic aldehyde at the concentrations contained in consumer products and fragrances, has a very low potential to induce hypersensitivity ('induced' reactions) or to elicit sensitization reactions ('elicited' reactions) in the general population.

  9. Occupational Contact Dermatitis in Mechanics and Repairers Referred for Patch Testing: Retrospective Analysis From the North American Contact Dermatitis Group 1998-2014.

    PubMed

    Warshaw, Erin M; Hagen, Solveig L; Sasseville, Denis; Maibach, Howard I; DeKoven, Joel G; Belsito, Donald V; Fowler, Joseph F; Zug, Kathryn A; Taylor, James S; Mathias, C G Toby; Fransway, Anthony F; DeLeo, Vincent A; Marks, James G; Pratt, Melanie D; Zirwas, Matthew J; Storrs, Frances J

    Contact dermatoses are common in mechanic and repair occupations. This study aimed to (1) estimate the prevalence of occupationally related contact dermatitis among mechanics/repairers patch tested from 1998 to 2014 by the North American Contact Dermatitis Group, (2) characterize responsible allergens and irritants, and their sources, and (3) compare results among 3 occupational subgroups (mechanics, electrical/electronic, and other). A cross-sectional analysis of patients patch tested by the North American Contact Dermatitis Group between 1998 and 2014. Of 38,784 patients patch tested, 691 (1.8%) were mechanics/repairers. Male sex (93.5%) and hand involvement (59.5%) were common overall. Occupationally related skin disease was more prevalent among vehicle and mobile equipment mechanics/repairers (52.7%) and other mechanics/repairers (41.4%) than electrical/electronic equipment mechanics/repairers (21.3%). Overall, carba mix, thiuram mix, and methylchloroisothiazolone/methylisothiazolone were the most common occupation-related clinically relevant allergens. Gloves, automotive vehicles, solvents, oils, lubricants, and fuels were the most common sources of responsible allergens. Common occupationally related allergens included rubber accelerators and the preservative methylchloroisothiazolone/methylisothiazolone.

  10. [Epidemiology of contact hypersensitivity to rubber components in manufacturers of automobile tires at the Stomil plant].

    PubMed

    Rubisz-Brzezińska, J; Bogdanowski, T; Brzezińska-Wcisło, L; Mozdzanowska, K; Bajcar, S

    1990-01-01

    Dermatological examination and patch tests with 34 rubber components were carried out in 114 tire manufacturers, 78 women and 36 men aged 29 years on average, with a mean duration of work in the plant 7 years. For correct interpretation of the obtained results patch tests with the same components were done in two control groups that is in 120 healthy subjects and 120 patients with contact dermatitis. Patch tests with proper concentrations of the studied components were evaluated after 48, 72 and 96 hours. Positive patch tests were found most frequently with antioxidants--16.6% (including IPPD--8.6%), followed by vulcanization accelerators--10.6%, and other rubber components--11.4% in all. During about 3 years of follow-up in 4 manufacturers contact allergic eczema was noted and polyvalent hypersensitivity to antioxidants and vulcanization accelerators without clinical manifestations of this hypersensitivity was diagnosed in 3 other subjects.

  11. Wet Wipe Allergens: Retrospective Analysis From the North American Contact Dermatitis Group 2011-2014.

    PubMed

    Warshaw, Erin M; Aschenbeck, Kelly A; Zug, Kathryn A; Belsito, Donald V; Zirwas, Matthew J; Fowler, Joseph F; Taylor, James S; Sasseville, Denis; Fransway, Anthony F; DeLeo, Vincent A; Marks, James G; Pratt, Melanie D; Maibach, Howard I; Mathias, C G Toby; DeKoven, Joel G

    Although there are several case reports of wet wipe-associated contact dermatitis, the prevalence of wipes as a source of allergic contact dermatitis in larger populations and the responsible allergens are largely unknown. The aim of the study was to determine the prevalence of wet wipes as a source of contact allergy and the most commonly associated allergens in a North American tertiary referral patch test population. Data collected from 2011 to 2014 by the North American Contact Dermatitis Group was used to conduct a retrospective cross-sectional analysis of patient demographics and patch test results associated with the triple-digit source code for "wet wipe." Of the 9037 patients patch tested during the study period, 79 (0.9%) had a positive patch test reaction to an allergen identified with a wet wipe source. The most commonly associated allergens were preservatives, including the following: methylisothiazolinone (MI) (59.0%), methylchloroisothiazolinone (MCI)/MI (35.6%), bronopol (2-bromo-2-nitropropane-1,3-diol) (27.4%), and iodopropynyl butylcarbamate (12.3%). Fragrance (combined) represented 12.3%. Anal/genital dermatitis was 15 times more likely (P < 0.0001) in those with wet wipe allergy. More than 92% of patients with wipe-associated contact allergy had their contact allergens detected by the North American Contact Dermatitis Group screening series. Wet wipes are an important source of contact allergy. Preservatives are the main allergens, especially isothiazolinones.

  12. Experimental elicitation with hydroxyisohexyl-3-cyclohexene carboxaldehyde-containing deodorants.

    PubMed

    Jørgensen, Pia Haslund; Jensen, Charlotte Devantier; Rastogi, Suresh; Andersen, Klaus Ejner; Johansen, Jeanne Duus

    2007-03-01

    Hydroxyisohexyl-3-cyclohexene carboxaldehyde (HICC) known as Lyral is a frequent allergen. It is used in more than 50% of marketed deodorants. The aim of the present study was to determine elicitation thresholds for HICC under simulated conditions of deodorant use. 15 patients with previously diagnosed contact allergy to HICC were patch tested with 5 solutions of HICC-scented and HICC-unscented deodorants. Patients and 10 healthy controls performed a use test in the axillae using deodorants scented with HICC in increasing concentrations and unscented deodorants as control. The concentration of HICC was increased every second week (200, 600, and 1800 p.p.m.) until either a reaction developed or for 6 weeks. 14 patients completed the study, and all developed unilateral eczema from the HICC-containing deodorant, while controls were all negative (P= 0.004). In 9/14 patients, a positive use test developed during the first 2 weeks to the deodorant containing 200 p.p.m. HICC. Positive correlations were found between the day of positive use and patch test threshold concentration of the HICC solutions (r= 0.71, P= 0.01) as well as the patch test thresholds of the HICC-scented deodorants (r= 0.74, P= 0.007). In conclusion, HICC elicits allergic contact dermatitis in a high proportion of sensitized individuals at common usage concentrations in deodorants.

  13. Positive concomitant test reactions to allergens in the standard patch test series.

    PubMed

    Landeck, Lilla; González, Ernesto; Baden, Lynn; Neumann, Konrad; Schalock, Peter

    2010-05-01

    Patch testing is performed to evaluate suspected allergic contact dermatitis. Common wisdom suggests that various allergens cross-react but only a few larger studies have published confirmations of this. The purpose of our study was to identify significant correlations between positive test reactions in a screening series. A total of 1235 patients undergoing patch testing to the Hermal standard series at the Massachusetts General Hospital, Contact Dermatitis Clinic between 1990 and 2006 were investigated. Two or more positive reactions were seen in 411 patients (33.3%). Sensitizations to eight pairs of allergens were found to have significant correlation (P

  14. Effects of Artcure Diffusional Patch application on pain and functional status in lumbar disc herniation patients: a prospective randomized controlled study.

    PubMed

    Uğurlu, Mahmut; Aksekili, Mehmet Atıf Erol; Alkan, Berat Meryem; Kara, Halil; Çağlar, Ceyhun

    2017-06-12

    The aim of this study was to assess the efficacy of the Artcure Diffusional Patch, which contains a mixture of 6 herbal oils (oleum thymi, oleum limonis, oleum nigra, oleum rosmarini, oleum chamomilla, oleum lauriexpressum) and has a hypoosmolar lipid structure, in the conservative treatment of lumbar disc herniation patients and to show the advantages and/or possibility of using this as an alternative method to surgery. Of the 120 patients enrolled, 79 clinically diagnosed patients were included in the study. Clinical evaluations were performed on patients who had findings of protrusion or extrusion in their magnetic resonance results. The treatment group was treated with the Artcure Diffusional Patch while the control group received a placebo transdermal diffusional patch. The functional state of patients was measured using the Oswestry Disability Index and pain intensity was measured with a visual analog scale as primary outcomes. Secondary outcomes of the study were Lasegue's sign, the femoral stretching test, and paravertebral muscle spasm. The treatment group showed a dramatic recovery in the first month following the application in regards to Oswestry Disability Index scores and visual analog scale values. The patients treated with the Artcure Diffusional Patch showed a statistically significant difference in recovery as compared to the control group. These findings suggest that the Artcure Diffusional Patch may be an alternative for the conservative treatment of lumbar disc herniation with radiculopathy.

  15. Quantitative patch and repeated open application testing in hydroxyisohexyl 3-cyclohexene carboxaldehyde sensitive-patients.

    PubMed

    Schnuch, Axel; Uter, Wolfgang; Dickel, Heinrich; Szliska, Christiane; Schliemann, Sibylle; Eben, Ricarda; Ruëff, Franziska; Gimenez-Arnau, Ana; Löffler, Harald; Aberer, Werner; Frambach, Yvonne; Worm, Margitta; Niebuhr, Margarete; Hillen, Uwe; Martin, Vera; Jappe, Uta; Frosch, Peter J; Mahler, Vera

    2009-09-01

    To identify the concentration of the fragrance compound hydroxyisohexyl 3-cyclohexene carboxaldehyde (INCI) (HICC) that is sufficiently low not to cause an allergic reaction in patients with proven sensitization. Repeated open application testing (ROAT) in 64 subjects with 2 preparations (perfume and cream) in different concentration (0.005-2.5%). Confirmatory patch testing with four preparations in two different concentrations (2.5% and 5%). The concentrations of HICC being tolerated by 90% of those sensitized to HICC are estimated as <88.2 ppm (cream) and <270 ppm (perfume) equivalent to 1.2 microg/cm(2) (perfume) and 4.9 microg/cm(2) (cream). Patch test preparations differed with regard to sensitivity (88.5-98.1%) and specificity (37.5-87.5%) against the ROAT result as external criterion. ROAT concentrations and the reaction strength in patch testing were inversely correlated (Kendall's tau-b: 0.69), both indicating the existence of different degrees of susceptibility. To protect 90% (50%) of people sensitized, the use concentration should be in the range of 0.009-0.027% (0.18-0.34%), depending on the product type. Taking into account these results, excessive concentrations should be avoided, as this would continue to sensitize people. Close monitoring is indispensable to prove the efficacy of any recommendations aiming to prevent induction.

  16. Cross-reactivity among epoxy acrylates and bisphenol F epoxy resins in patients with bisphenol A epoxy resin sensitivity.

    PubMed

    Lee, Han N; Pokorny, Christopher D; Law, Sandra; Pratt, Melanie; Sasseville, Denis; Storrs, Frances J

    2002-09-01

    The study's objective was 2-fold: first, to evaluate the potential cross-reactivity between Bis-A epoxy resins and epoxy acrylates and second, to study the cross reactivity between Bis-A epoxy resins and newer Bis-F epoxy resins in patients with allergic contact dermatitis to epoxy resins and had positive patch test to the standard epoxy resin based on bisphenol A. Forty-one patients were patch tested to 23 chemicals including epoxy acrylates, Bis-A epoxy resins, and Bis-F epoxy resins, as well as reactive diluents and nonbisphenol epoxy resins. Questions concerning exposure to epoxy resins, occupational history, and problems with dental work were completed. All patients included in the study had positive reactions to the standard Bis-A epoxy resin. Twenty percent (8 of 41) of the patients reacted to at least one of the epoxy acrylates; the most common reaction was to Bis-GMA. Five of 8 patients who reacted to the epoxy acrylates had dental work, but only one patient had problems from her dental work. Six of 8 patients (75%) who reacted to epoxy resins and epoxy acrylates did not react to aliphatic acrylates. Thirty-two percent (13 of 41) reacted to tosylamide epoxy resin, and none reacted to triglycidyl isocyanurate resin. In addition, all patients (100%) had positive reactions to at least one of the Bis-F epoxy resins that were tested. Most patients with sensitivity to Bis-A epoxy resins do not cross-react with epoxy acrylates. Patients with positive patch test reactions to epoxy acrylates used in dentistry usually do not have symptoms from their dental work. To our knowledge, this is the largest series of patients with sensitivity to the standard Bis-A epoxy resin that have been patch tested with the more recently introduced Bis-F epoxy resins. There is significant cross-reactivity between Bis-A and Bis-F epoxy resins, which can be explained by their structural similarity. Copyright 2002, Elsevier Science (USA). All rights reserved.

  17. [Drug patch tests in the investigation of a fixed drug eruption subsequent to 2 courses of cyclophosphamide in combination with mesna].

    PubMed

    Delaigue, S; Boye, T; Pasquine, C; Guetta, K; Alla, P; Ponte-Astoul, J; Morand, J-J

    2015-01-01

    When fixed drug eruption occurs following use of cyclophosphamide and mesna, it is difficult to establish which drug is responsible. We report a new case of patch tests that resulted in withdrawal of mesna and enabled continued treatment with cyclophophamide. A 57-year-old female patient with multiple sclerosis presented increasingly severe cutaneous lesions after successive courses of cyclophosphamide. Twenty-four hours after her latest treatment, she presented at the ER with a worse eruption than those to date and including facial lesions. The clinical diagnosis was a fixed drug eruption, and patch tests for mesna one month later were positive. Fixed drug eruption always occurs after recurrent treatment and the investigation must be precise. Patch tests may be used to determine which drug could be responsible. The most conclusive test comprises withdrawal of the incriminated drug with no further signs of drug eruption on resumption of the other medication. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  18. Pediatric Contact Dermatitis Registry Inaugural Case Data.

    PubMed

    Goldenberg, Alina; Mousdicas, Nico; Silverberg, Nanette; Powell, Douglas; Pelletier, Janice L; Silverberg, Jonathan I; Zippin, Jonathan; Fonacier, Luz; Tosti, Antonella; Lawley, Leslie; Wu Chang, Mary; Scheman, Andrew; Kleiner, Gary; Williams, Judith; Watsky, Kalman; Dunnick, Cory A; Frederickson, Rachel; Matiz, Catalina; Chaney, Keri; Estes, Tracy S; Botto, Nina; Draper, Michelle; Kircik, Leon; Lugo-Somolinos, Aida; Machler, Brian; Jacob, Sharon E

    2016-01-01

    Little is known about the epidemiology of allergic contact dermatitis (ACD) in US children. More widespread diagnostic confirmation through epicutaneous patch testing is needed. The aim was to quantify patch test results from providers evaluating US children. The study is a retrospective analysis of deidentified patch test results of children aged 18 years or younger, entered by participating providers in the Pediatric Contact Dermatitis Registry, during the first year of data collection (2015-2016). One thousand one hundred forty-two cases from 34 US states, entered by 84 providers, were analyzed. Sixty-five percent of cases had one or more positive patch test (PPT), with 48% of cases having 1 or more relevant positive patch test (RPPT). The most common PPT allergens were nickel (22%), fragrance mix I (11%), cobalt (9.1%), balsam of Peru (8.4%), neomycin (7.2%), propylene glycol (6.8%), cocamidopropyl betaine (6.4%), bacitracin (6.2%), formaldehyde (5.7%), and gold (5.7%). This US database provides multidisciplinary information on pediatric ACD, rates of PPT, and relevant RPPT reactions, validating the high rates of pediatric ACD previously reported in the literature. The registry database is the largest comprehensive collection of US-only pediatric patch test cases on which future research can be built. Continued collaboration between patients, health care providers, manufacturers, and policy makers is needed to decrease the most common allergens in pediatric consumer products.

  19. Patch test reactivity to a cobalt-chromium-molybdenum alloy and stainless steel in metal-allergic patients in correlation to the metal ion release.

    PubMed

    Summer, Burkhard; Fink, Ulrich; Zeller, Richard; Rueff, Franziska; Maier, Sonja; Roider, Gabriele; Thomas, Peter

    2007-07-01

    Nickel, chromium, and cobalt released from stainless steel and CoCrMo alloys have been postulated to trigger hypersensitivity reactions. The objective of this study was to assess the ion release from a CoCrMo alloy and stainless steel in vitro and the cutaneous reactivity to it by patch test. 52 metal-allergic patients and 48 non-allergic controls were patch tested to stainless steel and CoCrMo discs. In addition, using atomic absorption spectrometry, the release of nickel, cobalt, and chromium from both materials was assessed upon 2-day exposure to distilled water, artificial sweat (AS), and cell culture medium. There was low nickel ion release from stainless steel (0.3-0.46 microg/cm(2)/2 days) and CoCrMo discs (up to 0.33 microg/cm(2)/2 days) into the different elution media. Chromium release from the 2 materials was also very low (0.06-0.38 microg/cm(2)/2 days from stainless steel and 0.52-1.36 microg/cm(2)/2 days from CoCrMo alloy). In contrast, AS led to abundant cobalt release (maximally 18.94 microg/cm(2)/2 days) from the CoCrMo discs, with concomitant eczematous reaction upon patch testing: 0 of the 52 metal-allergic patients reacted to stainless steel discs and 5 of the 52 patients to CoCrMo discs (all 5 patients were cobalt allergic and 3 also nickel and chromium allergic). None of the controls reacted to the discs. Apart from nickel being a focus of allergological research, our results point to the possibly underestimated association of cobalt release and potential hyperreactivity to CoCrMo alloy.

  20. Relation of Nickel Allergy with in-Stent Restenosis in Patients Treated with Cobalt Chromium Stents.

    PubMed

    Aliağaoğlu, Cihangir; Turan, Hakan; Erden, Ismail; Albayrak, Hülya; Ozhan, Hakan; Başar, Cengiz; Gürlevik, Zehra; Alçelik, Ayşegül

    2012-11-01

    In-stent restenosis (ISR) is the major limitation of percutaneous coronary stenting procedure. The elements like nickel, chromate and molybdenum are known to cause contact allergy. Hypersensitivity reaction, against these metal ions, may be one of the reasons of ISR. Cobalt chromium coronary stents, which are increasingly being used in percutaneous coronary interventions, have more nickel amount than the stainless steel stents. We aimed to investigate the association between nickel hypersensitivity reaction and ISR in patients treated with cobalt chromium coronary stents. Epicutaneous patch tests for nickel were applied to 31 patients who had undergone elective cobalt chromium coronary stent implantation and had ISR in control angiogram. Thirty patients, without ISR, were included as the control group. Patch test results and other clinical variables were compared. There was no statistically significant difference of the mean age, sex, body mass index, rate of hypercholesterolemia, diabetes, hypertension and smoking between the patients with and without ISR. All other lesion characteristics were similar in the 2 groups. According to the patch test results, 7 patients had nickel contact allergy. All of these patients were in the ISR group, which was statistically significant (p<0.006). Patients treated with cobalt chromium coronary stents and had ISR were found to have significantly more nickel allergy than the control group. Nickel allergy may play role in restenosis pathophysiology.

  1. Making contact for contact dermatitis: a survey of the membership of the American Contact Dermatitis Society.

    PubMed

    Nezafati, Kaveh A; Carroll, Bryan; Storrs, Frances J; Cruz, Ponciano D

    2013-01-01

    The American Contact Dermatitis Society (ACDS) is the principal organization representing the subspecialty of contact dermatitis in the United States. The aim of this study was to characterize ACDS members with respect to demographic characteristics, patch-test practices, and sentiments regarding the Society and its journal Dermatitis. We conducted cross-sectional postal and online surveys of ACDS members. More than a third of ACDS members responded to the survey, 92% of whom practice dermatology, and most of whom are community practitioners. Responders manage patients with allergic and irritant dermatitis at a similar frequency. On average, they patch test 4 patients per week using 66 allergens per patient, which often include customized trays. Almost half of these practitioners learned patch testing from their residency programs. Most of the responders read and value the Society journal, value the Contact Allergen Management Program database, and attend society meetings. The ACDS is comprised overwhelmingly of dermatologists who are primarily community-based, young relative to the start of their practices, and use the Society's resources for continuing education.

  2. Allergic reaction to vanadium causes a diffuse eczematous eruption and titanium alloy orthopedic implant failure.

    PubMed

    Engelhart, Sally; Segal, Robert J

    2017-04-01

    Allergy as a cause of adverse outcomes in patients with implanted orthopedic hardware is controversial. Allergy to titanium-based implants has not been well researched, as titanium is traditionally thought to be inert. We highlight the case of a patient who developed systemic dermatitis and implant failure after surgical placement of a titanium alloy (Ti6Al4V) plate in the left foot. The hardware was removed and the eruption cleared in the following weeks. The plate and screws were submitted for metal analysis. The elemental composition of both the plate and screws included 3 major elements-titanium, aluminum, and vanadium-as well as trace elements. Metal analysis revealed that the plate and screws had different microstructures, and electrochemical studies demonstrated that galvanic corrosion could have occurred between the plate and screws due to their different microstructures, contributing to the release of vanadium in vivo. The patient was patch tested with several metals including components of the implant and had a positive patch test reaction only to vanadium trichloride. These findings support a diagnosis of vanadium allergy and suggests that clinicians should consider including vanadium when patch testing patients with a suspected allergic reaction to vanadium-containing implants.

  3. Methylisothiazolinone contact allergy in Croatia: Epidemiology and course of disease following patch testing.

    PubMed

    Ljubojević Hadžavdić, Suzana; Uter, Wolfgang; Ilijanić Samošćanec, Maja; Johansen, Jeanne D

    2018-05-30

    Methylisothiazolinone (MI) caused an epidemic of contact allergy in Europe, as shown by data from many countries, but no studies from Croatia exist. Also, data are lacking on the severity of allergic contact dermatitis (ACD) caused by MI, and its impact on quality of life and prognosis. To determine the frequency of MI contact allergy among Croatian dermatitis patients, identify causative exposures, assess the impact of disease, and study the prognosis. Data were collected for consecutive dermatitis patients with MI contact allergy patch tested in Croatia between November 2, 2015 and November 3, 2016. MI contact allergy was diagnosed in 13.2% of 798 tested patients. The most frequent dermatitis locations were the hands (76%) and face (61%). In 89.3% of patients, MI contact allergy was found to be of current relevance. Considerable severity and impact on daily life of disease was found at the first consultation, but this significantly decreased until follow-up 3 months later. Patch testing is the standard method for the diagnosis of ACD, and it has been shown to have an important beneficial effect on prognosis. The severity of MI ACD and the impact on daily life emphasize the need for prevention. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Airborne occupational allergic contact dermatitis from triglycidyl-p-aminophenol and tetraglycidyl-4,4'-methylene dianiline in preimpregnated epoxy products in the aircraft industry.

    PubMed

    Kanerva, L; Jolanki, R; Estlander, T; Henriks-Eckerman, M; Tuomi, M; Tarvainen, K

    2000-01-01

    Very little is known about allergic contact dermatitis (ACD) from preimpregnated epoxy products (prepregs). To describe a patient with occupational ACD from prepregs, and report new quantitative data on the content of prepregs. A laminator developed work-related vesicular hand dermatitis. He worked in an aircraft plant assembling aircraft parts, being exposed to preimpregnated carbon fiber and fiberglass sheets (prepregs), and epoxy adhesive tapes and foams. Triglycidyl-p-aminophenol (TGPAP; 1-0.25%, 2+; 0.05%, 1+) and tetraglycidyl-4,4'-methylene dianiline (TGMDA; 1%, 3+; 0.5-0.05%, 2+) provoked allergic patch test reactions, whereas o-diglycidyl phthalate was negative (1-0.05% pet) and standard epoxy provoked a weak (?+) reaction. Six prepreg products provoking allergic patch test reactions were analyzed for their TGPAP, TGMDA and diglycidyl ether of bisphenol A (DGEBA) content using gas and liquid chromatographic methods, showing up to 10% of TGPAP, 19% of TGMDA and 5% of DGEBA in the prepregs. An epoxy primer contained 61% of TGPAP. TGPAP and TGMDA caused occupational ACD. These chemicals need to be used when patch testing patients are exposed to prepregs, because patch testing with DGEBA may be negative. Copyright 2000 S. Karger AG, Basel.

  5. Shoe contact dermatitis from dimethyl fumarate: clinical manifestations, patch test results, chemical analysis, and source of exposure.

    PubMed

    Giménez-Arnau, Ana; Silvestre, Juan Francisco; Mercader, Pedro; De la Cuadra, Jesus; Ballester, Isabel; Gallardo, Fernando; Pujol, Ramón M; Zimerson, Erik; Bruze, Magnus

    2009-11-01

    The methyl ester form of fumaric acid named dimethyl fumarate (DMF) is an effective mould-growth inhibitor. Its irritating and sensitizing properties were demonstrated in animal models. Recently, DMF has been identified as responsible for furniture contact dermatitis in Europe. To describe the clinical manifestations, patch test results, shoe chemical analysis, and source of exposure to DMF-induced shoe contact dermatitis. Patients with suspected shoe contact dermatitis were studied in compliance with the Declaration of Helsinki. Patch test results obtained with their own shoe and the European baseline series, acrylates and fumaric acid esters (FAE), were recorded according to international guidelines. The content of DMF in shoes was analysed with gas chromatography and mass spectrometry. Acute, immediate irritant contact dermatitis and non-immunological contact urticaria were observed in eight adults and two children, respectively. All the adult patients studied developed a delayed sensitization demonstrated by a positive patch testing to DMF < or = 0.1% in pet. Cross-reactivity with other FAEs and acrylates was observed. At least 12 different shoe brands were investigated. The chemical analysis from the available shoes showed the presence of DMF. DMF in shoes was responsible for severe contact dermatitis. Global preventive measures for avoiding contact with DMF are necessary.

  6. A study of cross-reactions between mango contact allergens and urushiol.

    PubMed

    Oka, Keiko; Saito, Fumio; Yasuhara, Tadashi; Sugimoto, Akiko

    2004-01-01

    The allergens causing mango dermatitis have long been suspected to be alk(en)yl catechols and/or alk(en)yl resorcinols on the basis of observed cross-sensitivity reactions to mango in patients known to be sensitive to poison ivy and oak (Toxicodendron spp.). Earlier, we reported the 3 resorcinol derivatives: heptadecadienylresorcinol (I), heptadecenylresorcinol (II) and pentadecylresorcinol (III); collectively named 'mangol', as mango allergens. In this study, we extracted the 1st 2 components (I and II) from the Philippine mango, adjusted them to 0.05% concentration in petrolatum and patch tested the components on 2 subjects with mango dermatitis. Both subjects reacted to I. 1 subject also elicited a weaker positive reaction to II. To investigate the cross-reaction between mangol and urushiol, we also patch tested the same subjects with urushiol. The subject sensitive to II reacted to urushiol. 6 subjects with a history of lacquer contact dermatitis and positive reactions to urushiol were similarly patch tested. 5 persons reacted to I. 2 subjects also exhibited a slower but positive reaction to II. This is the 1st report in which heptadec(adi)enyl resorcinols known to be present in mango have been shown to elicit positive patch test reactions in mango-sensitive patients.

  7. Patch testing with the European baseline series fragrance markers: a 2016 update.

    PubMed

    Ung, C Y; White, J M L; White, I R; Banerjee, P; McFadden, J P

    2018-03-01

    Fragrance contact allergy is common and is currently screened for using the following European baseline series fragrance markers: fragrance mix (FM)I, FMII, Myroxylon pereirae and hydroxyisohexyl 3-cyclohexene carboxaldehyde. To investigate the validity of patch testing using these fragrance markers in detecting fragrance allergy to 26 individual fragrance substances for which cosmetic ingredient labelling is mandatory within the European Union. We conducted a retrospective review of the patch test records of all patients with eczema who underwent testing using the European baseline series, extended with the individual fragrance substances during the period from 2015 to 2016. Overall, 359 patients (17·2%) reacted to one or more allergens from the labelled fragrance substance series and/or a fragrance marker from the European baseline series. The allergens that were positive with the greatest frequencies were oxidized linalool [n = 154; 7·4%, 95% confidence interval (CI) 6·3-8·6], oxidized limonene (n = 89; 4·3%, 95% CI 3·4-5·2) and Evernia furfuracea (n = 44; 2·1%, 95% CI 1·5-2·8). Of the 319 patients who reacted to any of the labelled fragrance substances, only 130 (40·8%) also reacted to a baseline series fragrance marker. The sensitivity of our history-taking for detecting fragrance allergy was 25·7%. Given the evolving trends in fragrance allergy, patch testing with FMI, FMII, M. pereirae and hydroxyisohexyl 3-cyclohexene carboxaldehyde is no longer sufficient for screening for fragrance allergy. © 2017 British Association of Dermatologists.

  8. European Surveillance System on Contact Allergies (ESSCA): polysensitization, 2009-2014.

    PubMed

    Dittmar, Daan; Uter, Wolfgang; Bauer, Andrea; Fortina, Ana B; Bircher, Andreas J; Czarnecka-Operacz, Magdalena; Dugonik, Aleksandra; Elsner, Peter; Gallo, Rosella; Ghaffar, Sharizan A; Giménez-Arnau, Anna; Johnston, Graham A; Kręcisz, Beata; Filon, Francesca L; Rustemeyer, Thomas; Sadowska-Przytocka, Anna; Sánchez-Pérez, Javier; Schnuch, Axel; Simon, Dagmar; Spiewak, Radoslaw; Spring, Philipp; Corradin, Maria T; Valiukevičienė, Skaidra; Vok, Marko; Weisshaar, Elke; Wilkinson, Mark; Schuttelaar, Marie L

    2018-06-01

    Polysensitization, defined as being allergic to three or more haptens from the European baseline series, is considered to reflect increased susceptibility to developing a contact allergy, and is likely to be associated with an impaired quality of life. To evaluate the prevalences of polysensitization across Europe and to analyse factors associated with polysensitization. Patch test data collected by the European Surveillance System on Contact Allergies (ESSCA; www.essca-dc.org) in consecutively patch tested patients from January 2009 to December 2014, comprising 11 countries and 57 departments, were retrospectively analysed. A total of 86 416 patients were available for analysis, showing a standardized prevalence of polysensitization of 7.02%, ranging from 12.7% (Austria) to 4.6% (Italy). Allergen pairs with the strongest association are reported for the total population, for South Europe, and for North/Central Europe. Overall, polysensitized patients showed a higher percentage of extreme (+++) positive patch test reactions than oligosensitized patients. Female sex, occupational dermatitis and age > 40 years were risk factors for polysensitization. The varying prevalences of polysensitization across Europe most likely reflect differences in patient characteristics and referral patterns between departments. Known risk factors for polysensitization are confirmed in a European dermatitis population. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Computer-aided patch planning for treatment of complex coarctation of the aorta

    NASA Astrophysics Data System (ADS)

    Rietdorf, Urte; Riesenkampff, Eugénie; Kuehne, Titus; Huebler, Michael; Meinzer, Hans-Peter; Wolf, Ivo

    2009-02-01

    Between five and eight percent of all children born with congenitally malformed hearts suffer from coarctations of the aorta. Some severe coarctations can only be treated by surgical repair. Untreated, this defect can cause serious damage to organ development or even lead to death. Patch repair requires open surgery. It can affect patients of any age: newborns with severe coarctation and/or hypoplastic aortic arch as well as older patients with late diagnosis of coarctation of the aorta. Another patient group are patients of varying age with re-coarctation of the aorta or hypoplastic aortic arch after surgical and/or interventional repair. If anatomy is complex and interventional treatment by catheterization, balloon angioplasty or stent placement is not possible, surgery is indicated. The choice of type of surgery depends not only on the given anatomy but also on the experience the surgical team has with each method. One surgical approach is patch repair. A patch of a suitable shape and size is sewed into the aorta to expand the aortic lumen at the site of coarctation. At present, the shape and size of the patch are estimated intra-operatively by the surgeon. We have developed a software application that allows planning of the patch pre-operatively on the basis of magnetic resonance angiographic data. The application determines the diameter of the coarctation and/or hypoplastic segment and constructs a patch proposal by calculating the difference to the normal vessel diameter pre-operatively. Evaluation of MR angiographic datasets from 12 test patients with different kinds of aortic arch stenosis shows a divergence of only (1.5+/-1.2) mm in coarctation diameters between manual segmentations and our approach, with comparable time expenditure. Following this proposal the patch can be prepared and adapted to the patient's anatomy pre-operatively. Ideally, this leads to shorter operation times and a better long-term outcome with a reduced rate of residual stenosis and re-stenosis and aneurysm formation.

  10. Supplemental tests in the evaluation of occupational hand dermatitis in soldiers.

    PubMed

    Wolf, R; Movshowitz, M; Brenner, S

    1996-03-01

    Hand dermatitis in soldiers is a considerable problem. The purpose of the study was to evaluate appropriate screening tests to improve the diagnosis of hand dermatitis in soldiers. A group of 111 soldiers with occupational dermatitis from contact with fuels and oils underwent "tailored patch tests" with allergens relevant to their field of work and their environment. The control group consisted of 24 soldiers with various jobs similar to those of civilian life, who had not been exposed to oils and fuels. Seventy-three civilian patients, attending the clinic for patch testing, were also included. Twenty soldiers, who had a history of intensive contact with oil and fuels, but no contact dermatitis, and who were admitted because of various skin diseases (fungal infections, acne, etc.) also underwent the supplemental testing and served as an additional control group. Of the soldiers, 31 (29%) showed one or more positive skin tests of the oil series and 30 patients of this group one or more positive reactions to the standard patch tests trays. No patient of the control groups had a positive test to the oil series. Our results show the value of the supplementary tests as a first-step screening test for detection of oil allergy in soldiers and automobile-mechanics or in workers handling other gasoline- or diesel-powered engineering equipment. The test method appears to be practical, easy to perform, reliable and giving clear and accurate results, with a negligible rate of false positive reactions.

  11. A hydrogel pericardial patch.

    PubMed

    Allder, M A; Guilbeau, E J; Brandon, T A; Walker, A S; Koeneman, J B; Fisk, R L

    1990-01-01

    Patients undergoing repeat cardiac operations are higher operative risks than those undergoing an initial cardiac procedure because adhesion formation can occur if the native pericardium is not closed. A unique composite patch that may be used to augment the pericardial tissue when primary closure is not possible has been developed. The patch is made of a hydrogel, poly (2-hydroxyethyl methacrylate), reinforced with an ethylene tetrafluoroethylene (ETFE) mesh. The mesh provides the needed mechanical properties, whereas the patch's surface properties are comparable to the hydrogel. Two types of patches were fabricated: one with the mesh weave at a perpendicular orientation and one at 45 degrees to the principle loading direction. The patches were mechanically tested and compared with canine pericardium. Ultimate tensile strength of the patches is not significantly different from canine pericardium (p less than 0.05), are the patch suture strength is nearly twice that of canine pericardium. The perpendicular patch is stiffer than canine pericardium, whereas the 45 degree patch is not (p less than 0.05). The 45 degree patch shows considerable promise as a pericardial substitute because it closely matches the properties native canine pericardium.

  12. Corticosteroid hypersensitivity studies in a skin allergy clinic.

    PubMed

    Berbegal, L; DeLeon, F J; Silvestre, J F

    2015-12-01

    Corticosteroids can cause hypersensitivity reactions, particularly delayed-type allergic reactions. A new classification system for testing hypersensitivity to corticosteroids distributes the drugs into 3 groups according to molecular structure; patients are classified according to whether they are allergic to agents in 1 or more of the groups. We aimed to describe the clinical characteristics of corticosteroid-allergic patients treated at our clinic and apply the new classification system to them; we also compared these patients' characteristics to those of others treated at our clinic. Retrospective study of cases of delayed-type corticosteroid hypersensitivity treated in the skin allergy clinic of a tertiary level hospital over an 11-year period. We reviewed the records of 2857 patients, finding 33 with at least one positive patch test result showing corticosteroid hypersensitivity. Atopic dermatitis and hand involvement were less common in our corticosteroid-allergic patients. All were allergic to a group 1 corticosteroid (most often, budesonide, the culprit in 87.9%). Testing with a specific corticosteroid series revealed that 14 (42.4%) were also allergic to corticosteroids in group 2 and/or group 3. None were allergic exclusively to group 2 or group 3 agents. Twenty-one patients were exposed to a corticosteroid cream from a group their patch test results indicated allergy to; 13 of them (61.9%) did not develop a hypersensitivity reaction. The Spanish standard series only contains group 1 corticosteroids. In the interest of improving allergy management, we recommend testing with a specific corticosteroid series and a patient's own creams whenever patch testing with a standard series reveals a hypersensitivity reaction to corticosteroids. Copyright © 2015 Elsevier España, S.L.U. and AEDV. All rights reserved.

  13. 24 and 48 h allergen exposure in patch testing. Comparative study with 11 common contact allergens and NiCl2.

    PubMed

    Kalimo, K; Lammintausta, K

    1984-01-01

    Patch test reactions to 11 common contact allergens were studied after 24 h and 48 h occlusion with Finn Chambers in 390 patients. Concordant allergic results were found in 96 cases (74%). In 22 patients (17%), the reaction was positive only after 48 h and in 11 cases (8.5%) only after 24 h exposure. Most of the discordant reactions were to nickel, cobalt, neomycin, formaldehyde and perfume mix. Irritant reactions were found in 55 cases, the majority occurring after 48 h occlusion. Nickel chloride tested in parallel with 48 h exposure lead to more positive allergic and toxic reactions than nickel sulphate.

  14. Lack of Association Between Dust Mite Sensitivity and Atopic Dermatitis.

    PubMed

    Silverberg, Jonathan Ian; Hanifin, Jon M; Law, Sandra; White, Kevin; Storrs, Frances J

    2016-01-01

    Dust mites (DMs) play a role in type I respiratory allergy. Studies relating to DM irritant versus immune reactions are somewhat conflicting in atopic dermatitis (AD). The aim of this study was to assess the diagnostic use of patch testing to DM in patients with AD and other dermatitides. We performed a prospective study of 323 adults recruited in a patch testing clinic. Patch testing antigens were DM extract (0.01%, 0.1%, 1%, 10%, and 20% in petrolatum; Chemotechnique) and/or 200 index of reactivity in petrolatum (Stallergenes). Patches were placed and read at 48 hours with delayed readings after 72 to 168 hours. There was no association of DM positivity with AD, asthma, hay fever, or demographic factors. There was no association of DM positivity with the clinical diagnosis or phenotype. The number of positive (+, ++, and +++) and doubtful reactions to Chemotechnique DM extract increased with higher concentrations. Positive reactions to DM had a morphological appearance characterized by numerous discrete erythematous papules and, rarely, papulovesicles. Positive reactions to Stallergenes DM 200 IR were infrequent and all weak reactions, similar to DM 0.01%. Patch testing to DM does not seem to have clinical use for determining the etiology of dermatitis.

  15. Essential Oils, Part IV: Contact Allergy.

    PubMed

    de Groot, Anton C; Schmidt, Erich

    2016-01-01

    Nearly 80 essential oils (including 2 jasmine absolutes) have caused contact allergy. Fifty-five of these have been tested in consecutive patients suspected of contact dermatitis, and nine (laurel, turpentine, orange, tea tree, citronella, ylang-ylang, sandalwood, clove, and costus root) showed greater than 2% positive patch test reactions. Relevance data are generally missing or inadequate. Most reactions are caused by application of pure oils or high-concentration products. The clinical picture depends on the responsible product. Occupational contact dermatitis may occur in professionals performing massages. The (possible) allergens in essential oils are discussed. Several test allergens are available, but patients should preferably be tested with their own products. Co-reactivity with other essential oils and the fragrance mix is frequent, which may partly be explained by common ingredients. Patch test concentrations for essential oils are suggested.

  16. A comparative analysis of metal allergens associated with dental alloy prostheses and the expression of HLA-DR in gingival tissue

    PubMed Central

    ZHANG, XIN; WEI, LI-CHENG; WU, BIN; YU, LI-YING; WANG, XIAO-PING; LIU, YUE

    2016-01-01

    The present study aimed to provide guidance for the selection of prosthodontic materials and the management of patients with a suspected metal allergy. This included a comparison of the sensitivity of patients to alloys used in prescribed metal-containing prostheses, and correlation analysis between metal allergy and accompanying clinical symptoms of sensitized patients using a patch test. The results from the patch test and metal component analyses were processed to reach a final diagnosis. In the present study, four dental alloys were assessed. Subsequent to polishing the surface of a metal restoration, the components were analyzed using an X-ray fluorescence microscopy and spectrometry. Immunohistochemical analysis, reverse transcription-polymerase chain reaction and western blotting were used to detect the expression levels of human leukocyte antigen (HLA)-DR in gingival tissues affected by alloy restoration, and in normal gingival tissue samples. Positive allergens identified in the patch test were consistent with the components of the metal prostheses. The prevalence of nickel (Ni) allergy was highest (22.8%), and women were significantly more allergic to palladium and Ni than men (P<0.05). The protein and gene expression levels of HLA-DR in the Ni-chromium (Cr) prosthesis group were significantly higher, compared with those in the other groups (P<0.01); followed by cobalt-Cr alloy, gold alloy and titanium alloy. In conclusion, dentists require an understanding of the corrosion and allergy rates of prescribed alloys, in order to reduce the risk of allergic reactions. Patch testing for hypersensitive patients is recommended and caution is required when planning to use different alloys in the mouth. PMID:26573458

  17. Efficacy of Atopy Patch Testing in Directed Dietary Therapy of Eosinophilic Esophagitis: A Pilot Study.

    PubMed

    Eckmann, Jason D; Ravi, Karthik; Katzka, David A; Davis, Dawn R; See, Jacalyn A; Geno, Debra R; Kryzer, Lori A; Alexander, Jeffrey A

    2018-03-01

    Atopy patch testing (APT) has shown potential for predicting dietary food triggers in studies of children and adolescents with eosinophilic esophagitis (EoE). To assess the efficacy of APT in adults with EoE. We conducted a prospective open-label pilot study of patients ≥ 18 years old with diagnosis of EoE at Mayo Clinic in Rochester, Minnesota, from November 2014 to January 2016. All patients underwent patch testing using intact food products, followed by a six food elimination diet and stepwise food reintroduction. Response to elimination diet was assessed with serial endoscopy with biopsies as well as clinical symptoms. APT results were directly compared to elimination diet results for assessment of efficacy. Correlation between clinical symptoms, endoscopic score, and histology was also qualitatively evaluated. Fifty percent of the patients had a positive APT, while only 16% had an APT result confirmed histologically during food reintroduction. Sensitivity of APT was calculated to be 5.9%, with specificity of 92.0%. Furthermore, we found significant qualitative inter-patient heterogeneity in the correlation between clinical symptoms, EREFS score, and histology. APT does not reliably predict food triggers identified by food elimination diet in adult patients with EoE. As a result, APT does not have a clear role in the evaluation of patients with EoE.

  18. Non-IgE-related diagnostic methods (LST, patch test).

    PubMed

    Matsumoto, Kenji

    2015-01-01

    Although most food allergy patients have immediate-type reactions, some have delayed-type reactions. Unlike for the detection of food-specific IgE antibody in immediate-type (IgE-mediated) food allergies, only a few tests are currently available to aid in the diagnosis of delayed-type (non-IgE-mediated) food allergies. This chapter summarizes our current understanding of one in vitro test and one in vivo test for non-IgE-mediated food allergies: the lymphocyte stimulation test (LST) and the atopy patch test (APT). Although the LST is not yet standardized, a food protein-specific LST might be a useful tool for diagnosing delayed-type food allergies, and especially those manifesting with gastrointestinal symptoms but not skin symptoms. Various remaining issues - including basophil contamination of the peripheral blood mononuclear cell fraction and lipopolysaccharide contamination of food antigen preparations - are also discussed. The APT uses an epicutaneous patch technique to occlusively apply food antigens to the skin to induce inflammatory reactions at the patch application site. Because the APT shows modest sensitivity and specificity, the clinical benefit of the APT in the diagnosis of food allergies in patients with atopic dermatitis is limited. A position paper on the APT issued by the European Academy of Allergy and Clinical Immunology/Global Allergy and Asthma European Network in 2006 is briefly summarized, and several recent APT-related topics, including APT use for the diagnosis of food protein-induced enterocolitis syndrome, are discussed. © 2015 S. Karger AG, Basel.

  19. Application of a cold patch for relieving pain after transepithelial photorefractive keratectomy

    PubMed Central

    Zeng, Yuan; Li, Yi; Gao, Jian-Hua

    2015-01-01

    BACKGROUND: A return toward toward photorefractive keratectomy has occurred due to better corneal stability and fewer corneal flap complications; however, pain remains a major drawback of the procedure. Currently, clinical pain control measures focus on the administration of pain medications, which may delay corneal epithelial healing and has, occasionally, led to serious corneal toxicity. OBJECTIVES: To investigate the safety and efficacy of a cold patch on postoperative pain and other relevant consequences of transepithelial photorefractive keratectomy. METHODS: A prospective, randomized controlled study was conducted. Forty patients (80 eyes) scheduled to undergo transepithelial photorefractive keratectomy for myopia or myopic astigmatism were randomly and equally assigned to be treated with ice-cold balanced salt solution during surgery (wash group) or to wear a postoperative cold patch on the eye for 24 h. The main outcomes were pain score on a visual analogue scale, postoperative eyelid edema, conjunctival hyperemia, epithelial healing time, haze and postoperative best-corrected visual acuity. RESULTS: All patients completed the final tests. Demographic characteristics and pain scores during surgery were similar between the two groups. The mean postoperative pain scores of patients in the cold patch group at 8 h, 16 h and 24 h were significantly lower than those of patients in the wash group. Scores for postoperative eyelid edema and conjunctival hyperemia in the cold patch group were also lower than in the wash group. Patients in the cold patch group used fewer painkillers. Epithelial healing time, haze and early recovery of visual acuity were similar between the two groups. No eyelid frostbite was observed. CONCLUSION: Wearing a cold patch on the eye after transepithelial photorefractive keratectomy effectively relieved pain and inflammation, and reduced the use of painkillers without any side effects. PMID:25992866

  20. Study on cross-reactivity to the para group.

    PubMed

    Picardo, M; Cannistraci, C; Cristaudo, A; De Luca, C; Santucci, B

    1990-01-01

    In 80 patients, positive to at least one hapten of the para group (para-phenylenediamine, diaminodiphenylmethane, benzocaine, PPD mix), patch tests were carried out with freshly prepared solutions of para-phenylenediamine (PPD) and of 3 selected aromatic compounds related structurally to PPD (para-aminophenol, ortho-aminophenol, hydroquinone). The number of positive reactions correlated with the rate of decomposition of the substances as evaluated by high-pressure liquid chromatography. PPD, which was almost decomposed after 24 h, gave the highest number of positive reactions, followed by ortho-aminophenol and by para-aminophenol, while hydroquinone, which was oxidized to the extent of 35%, did not give any reactions. To evaluate if a different rate of oxidation can modify the patch test response, in the same patients and in 10 normal volunteers, tests were carried out with PPD solutions containing the oxidizing agent silver oxide (0.1%). By this procedure a significant increase in the number of positive responses was observed. The results suggest that the rate of decomposition and therefore the amount of quinone(s) generated, might be the key to eliciting patch test responses to oxidizable aromatic haptens.

  1. Occupational allergic contact dermatitis and patch test results of leather workers at two Indonesian tanneries.

    PubMed

    Febriana, Sri Awalia; Jungbauer, Frank; Soebono, Hardyanto; Coenraads, Pieter-Jan

    2012-11-01

    Tannery workers are at considerable risk of developing occupational contact dermatitis. Occupational skin diseases in tannery workers in newly industrialized countries have been reported, but neither the prevalence of occupational allergic contact dermatitis nor the skin-sensitizing agents were specifically examined in those studies. To assess the prevalence of occupational allergic contact dermatitis in Indonesian tanneries, identify the causative allergens, and propose a tannery work series of patch test allergens. A cross-sectional study in all workers at two Indonesian tanneries was performed to assess the prevalence of occupational contact dermatitis via a questionnaire-based interview and skin examination. Workers with occupational contact dermatitis were patch tested to identify the causative allergens. Occupational contact dermatitis was suspected in 77 (16%) of the 472 workers. Thirteen (3%) of these 472 workers were confirmed to have occupational allergic contact dermatitis. Potassium dichromate (9.2%), N,N-diphenylguanidine (5.3%), benzidine (3.9%) and sodium metabisulfite (2.6%) were found to be the occupationally relevant sensitizers. The sensitization pattern showed some differences from the data in studies reported from other newly industrial countries. We compiled a 'tannery work series' of allergens for patch testing. A number of these allergens may also be considered for patch testing in patients with (leather) shoe dermatitis. © 2012 John Wiley & Sons A/S.

  2. Food patch testing for irritable bowel syndrome.

    PubMed

    Stierstorfer, Michael B; Sha, Christopher T; Sasson, Marvin

    2013-03-01

    The traditional classification of irritable bowel syndrome (IBS) as a functional disorder has been challenged in recent years by evidence of ongoing low-grade gastrointestinal tract inflammation. Inflammation may alter gastrointestinal motility and thus be central to the pathogenesis of IBS. Many foods and food additives are known to cause allergic contact dermatitis. We hypothesize that allergenic foods and food additives may elicit a similar allergic reaction in the gastrointestinal tract, giving rise to symptoms suggestive of IBS. We sought to determine whether skin patch testing to a panel of foods and food additives may identify food allergens that may be responsible for symptoms of IBS. We performed skin patch testing to common allergenic foods and food additives on individuals with a history of or symptoms suggestive of IBS. We used patch test-guided avoidance diets to determine whether avoidance alleviates IBS symptoms. Thirty of the 51 study participants showed at least 1 doubtful or positive patch test result. Fourteen of the participants reported symptomatic improvement, ranging from slight to great, upon avoidance of the foods/food additives to which they reacted. Double-blind study design, inclusion of only patients with active IBS, larger sample size, more balanced gender distribution, testing of more foods/food additives, and longer duration of and more precise quantification of response to dietary avoidance are suggested for future studies. Allergic contact enteritis to ingested foods, food additives, or both may contribute to IBS symptoms. Patch testing may be useful in identifying the causative foods. Copyright © 2012 American Academy of Dermatology, Inc. Published by Mosby, Inc. All rights reserved.

  3. [Relevant allergans by periorbital allergic contact dermatitis. Oxybuprocain, an underestimated allergen].

    PubMed

    Blaschke, V; Fuchs, T

    2003-08-01

    Periorbital allergic contact dermatitis is a rare disease and the main differential diagnoses are atopic and seborrhoeic dermatitis. The diagnosis is based on clinical appearance, patient history and patch testing. Current systematic overviews on contact allergens involved are lacking and with changes in medical preparations, new relevant antigens may emerge. Based on the systematic data of the information network of dermatological clinics (IVDK), patch test reactions in 48,969 patients tested between 1996 and 2000 were evaluated. A total of 763 patients suffered from periorbital dermatitis which was suspected to be due to the use of topical medication. The most common epidermal sensitizations in the general population were observed against nickel and fragrances. In the periorbital dermatitis group, sensitization against local anaesthetics and antibiotics was more frequent than in the general population. In three patients, oxybuprocain was identified as the causative agent, which has not yet been recognized as a common allergen.

  4. Identification of Lilial as a fragrance sensitizer in a perfume by bioassay-guided chemical fractionation and structure-activity relationships.

    PubMed

    Arnau, E G; Andersen, K E; Bruze, M; Frosch, P J; Johansen, J D; Menné, T; Rastogi, S C; White, I R; Lepoittevin, J P

    2000-12-01

    Fragrance materials are among the most common causes of allergic contact dermatitis. The aim of this study was to identify in a perfume fragrance allergens not included in the fragrance mix, by use of bioassay-guided chemical fractionation and chemical analysis/structure-activity relationships (SARs). The basis for the investigation was a 45-year-old woman allergic to her own perfume. She had a negative patch test to the fragrance mix and agreed to participate in the study. Chemical fractionation of the perfume concentrate was used for repeated patch testing and/or repeated open application test on the pre-sensitized patient. The chemical composition of the fractions giving a positive patch-test response and repeated open application test reactions was obtained by gas chromatography-mass spectrometry. From the compounds identified, those that contained a "structural alert" in their chemical structure, indicating an ability to modify skin proteins and thus behave as a skin sensitizer, were tested on the patient. The patient reacted positively to the synthetic fragrance p-t-butyl-alpha-methylhydrocinnamic aldehyde (Lilial), a widely used fragrance compound not present in the fragrance mix. The combination of bioassay-guided chemical fractionation and chemical analysis/structure-activity relationships seems to be a valuable tool for the investigation of contact allergy to fragrance materials.

  5. Patch testing with hydroxyisohexyl 3-cyclohexene carboxaldehyde (HICC) - a multicentre study of the Swedish Contact Dermatitis Research Group.

    PubMed

    Engfeldt, Malin; Hagvall, Lina; Isaksson, Marléne; Matura, Mihály; Mowitz, Martin; Ryberg, Kristina; Stenberg, Berndt; Svedman, Cecilia; Bruze, Magnus

    2017-01-01

    In 2014, the fragrance hydroxyisohexyl 3-cyclohexene carboxaldehyde (HICC) was excluded from the Swedish baseline series. To study (i) whether fragrance mix (FM) II with 5% HICC detects more positive reactions than usual FM II with 2.5% HICC, and (ii) the reproducibility of patch testing with HICC. Two thousand one hundred and eighteen dermatitis patients at five Swedish dermatology departments were consecutively tested with FM II 14% pet., FM II 16.5% pet., and duplicate preparations of HICC 5% pet. Of the patients, 3.2% reacted to FM II 14%, and 1.5% reacted to HICC. Separate testing with HICC detected 0.3% reactions without concomitant reactivity to FM II. FM II with 5% HICC did not give rise to more irritant reactions or signs of active sensitization than FM II with 2.5% HICC. Patch testing with duplicate applications of HICC increased the overall prevalence of HICC contact allergy to 1.9%. FM II with 5% HICC does not detect more positive reactions than FM II with 2.5% HICC. Separate testing with HICC does not detect a sufficient proportion of patients who react only to HICC, without concomitant reactions to FM II, to warrant its inclusion in a baseline series. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Patch testing with fragrances: results of a multicenter study of the European Environmental and Contact Dermatitis Research Group with 48 frequently used constituents of perfumes.

    PubMed

    Frosch, P J; Pilz, B; Andersen, K E; Burrows, D; Camarasa, J G; Dooms-Goossens, A; Ducombs, G; Fuchs, T; Hannuksela, M; Lachapelle, J M

    1995-11-01

    The objective of this study was to determine the frequency of reactivity to a series of commonly used fragrances in dermatological patients. A total of 48 fragrances (FF) were chosen, based on the publication of Fenn in 1989 in which the top 25 constituents of 3 types (1. perfumes, 2. household products, 3. soaps) of 400 commercial products on the US market had been determined. In a pilot study on a total of 1069 patients in 11 centres, the appropriate test concentration and vehicle were examined. For most fragrances, 1% and 5% were chosen, and petrolatum proved to be the best vehicle in comparison to isopropyl myristate and diethyl phthalate. In the main study, a set of 5 to 10 fragrances at 2 concentrations was patch tested in each centre on a minimum of 100 consecutive patients seen in the patch test clinic. These patients were also patch tested to a standard series with the 8% fragrance mix (FM) and its 8 constituents. In patients with a positive reaction to any of the 48 FF, a careful history with regard to past or present reactions to perfumed products was taken. A total of 1323 patients were tested in 11 centres. The 8% FM was positive in 89 patients (8.3% of 1072 patients). Allergic reactions to the constituents were most frequent to oak moss (24), isoeugenol (20), eugenol (13), cinnamic aldehyde (10) and geraniol (8). Reactions read as allergic on day 3/4 were observed only 10X to 7 materials of the new series (Iso E Super (2), Lyral (3), Cyclacet (1), DMBCA (1), Vertofix (1), citronellol (1) and amyl salicylate (1)). The remaining 41 fragrances were negative. 28 irritant or doubtful reactions on day 3/4 were observed to a total of 19 FF materials (more than 1 reaction: 5% citronellol (2), 1% amyl salicylate (2), 1% isononyl acetate (3), 0.1% musk xylol (2), 1% citral (2), and 1% ionone beta (2)). Clinical relevance of positive reactions to any of the FF series was not proved in a single case. This included the 4 reactions in patients who were negative to the 8% FM. In conclusion, the top 25 fragrances commonly found in various products caused few reactions in dermatological patients and these few appeared to be clinically irrelevant, with the possible exception of Lyral. However, this data should be interpreted in the light of the relatively small number of patients tested (only 100 in most centres).

  7. Allergy to cosmetics: a literature review.

    PubMed

    Alani, Jennifer I; Davis, Mark Denis P; Yiannias, James A

    2013-01-01

    The term cosmetic has a broad definition and includes personal care products, hair care products, nail care products, and sunscreens. Modern cosmetics are safe for most users, and adverse reactions are very rare because the manufacturers invest heavily in safety, quality control, and product testing before releasing the product to the market. Despite these efforts, adverse reactions occur. Skin care products are major contributors to cosmetic allergic contact dermatitis (ACD), followed by hair care and nail care products. The most common allergens are fragrances and preservatives. The diagnosis of cosmetic allergy is established by reviewing the patient's clinical history and physical examination findings and confirmed with skin patch testing. Patch testing is the standard method for detecting allergens responsible for eliciting ACD. The purpose of this article was to review the prevalence, legislative laws, and role of patch testing in ACD.

  8. North American Contact Dermatitis Group patch test results for 2007-2008.

    PubMed

    Fransway, Anthony F; Zug, Kathryn A; Belsito, Donald V; Deleo, Vincent A; Fowler, Joseph F; Maibach, Howard I; Marks, James G; Mathias, C G Toby; Pratt, Melanie D; Rietschel, Robert L; Sasseville, Denis; Storrs, Frances J; Taylor, James S; Warshaw, Erin M; Dekoven, Joel; Zirwas, Matthew

    2013-01-01

    The North American Contact Dermatitis Group (NACDG) tests patients with suspected allergic contact dermatitis to a broad series of screening allergens and publishes periodic reports. The aims of this study were to report the NACDG patch-testing results from January 1, 2007, to December 31, 2008, and to compare results to pooled test data from the previous 2 and 10 years to analyze trends in allergen sensitivity. Standardized patch testing with 65 allergens was used at 13 centers in North America. χ analysis was used for comparisons. A total of 5085 patients were tested; 11.8% (598) had an occupationally related skin condition, and 65.3% (3319) had at least 1 allergic patch test reaction, which is identical to the NACDG data from 2005 to 2006. The top 15 most frequently positive allergens were nickel sulfate (19.5%), Myroxylon pereirae (11.0%), neomycin (10.1%), fragrance mix I (9.4%), quaternium-15 (8.6%), cobalt chloride (8.4%), bacitracin (7.9%), formaldehyde (7.7%), methyldibromoglutaronitrile/phenoxyethanol (5.5%), p-phenylenediamine (5.3%), propolis (4.9%), carba mix (4.5%), potassium dichromate (4.1%), fragrance mix II (3.6%), and methylchloroisothiazolinone/methylisothiazolinone (3.6%). There were significant increases in positivity rates to nickel, methylchloroisothiazolinone/methylisothiazolinone, and benzophenone-3. During the same period of study, there were significant decreases in positivity rates to neomycin, fragrance mix I, formaldehyde, thiuram mix, cinnamic aldehyde, propylene glycol, epoxy resin, diazolidinyl urea, amidoamine, ethylenediamine, benzocaine, p-tert-butylphenol formaldehyde resin, dimethylol dimethyl hydantoin, cocamidopropyl betaine, glutaraldehyde, mercaptobenzothiazole, tosylamide formaldehyde resin, budesonide, disperse blue 106, mercapto mix, and chloroxylenol. Twenty-four percent (1221) had a relevant positive reaction to a non-NACDG supplementary allergen; and 180 of these reactions were occupationally relevant. Periodic analysis, surveillance, and publication of multicenter study data sets document trends in allergen reactivity incidence assessed in the patch test clinic setting and provide information on new allergens of relevance.

  9. Lichenoid dermatitis after consumption of gold-containing liquor.

    PubMed

    Russell, M A; Langley, M; Truett, A P; King, L E; Boyd, A S

    1997-05-01

    Medicinal gold has a well-known side effect profile that includes mucocutaneous eruptions. We describe three patients with a pruritic dermatitis that began after consumption of a gold-containing alcoholic beverage. Blood and urine gold levels, chemistry panels, hepatitis screens, skin biopsies, and patch tests were performed. The gold-containing liquor was analyzed for the presence and quantity of gold. The liquor consumed by all of the patients was a cinnamon schnapps with free-floating gold-colored flakes. Gold is present in the liquid portion of this liquor and in the solid flakes. Elevated levels of gold in the urine and blood were present in one patient 3 months after last drinking this beverage. Another patient had a positive patch test to gold sodium thiosulfate. All patients experienced improvement of their dermatitis after they stopped drinking the gold-containing liquor.

  10. Fragrance allergy could be missed without patch testing with 26 individual fragrance allergens.

    PubMed

    Vejanurug, Patnapa; Tresukosol, Poohglin; Sajjachareonpong, Praneet; Puangpet, Pailin

    2016-04-01

    In 2003, the EU Cosmetics Directive stated that 26 fragrance substances must be listed on the cosmetic product ingredient labels. Not all of these 26 fragrance substances are detected by the usual screening markers comprising fragrance mix I, fragrance mix II, and Myroxylon pereirae. To evaluate the usefulness of testing with the 26 individual fragrance substances in addition to the standard fragrance screening markers. Three hundred and twelve consecutive patients were patch tested with our baseline series and the 26 specific fragrance substances required to be declared on cosmetic product ingredient labels in accordance with the EU Cosmetics Directive. Positive reactions to at least either one of the 26 individual fragrance substances or the usual fragrance screening markers were seen in 84 of 312 patients (26.9%). Fifteen of these 84 patients (17.8%) reacted negatively to the fragrance screening markers. The most common individual fragrance allergens were cinnamyl alcohol (11.2%), cinnamal (9%), and hydroxycitronellal (3.8%). Sixty-two of 312 patients (19.8%) had at least one positive reaction to the fragrance screening markers. Additional patch testing with the 26 individual fragrance allergens, or with the commonest fragrance allergens identified within these 26, should be performed to optimize the detection of fragrance allergy. Cinnamyl alcohol and cinnamal are important fragrance allergens in Thailand. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Contact dermatitis caused by tulips: identification of contact sensitizers in tulip workers of Kashmir Valley in North India.

    PubMed

    Hassan, Iffat; Rasool, Farhan; Akhtar, Saniya; Kamili, Afifa; Rather, Parvaiz; Kanth, Raihana; Bhat, Yasmeen; Rather, Shagufta; Mubashir, Syed; Yaseen, Atiya; Bashir, Safia

    2018-01-01

    Tulip, belonging to the genus Tulipa and family Liliaceae, is a spring-blooming perennial that grows from bulbs. Owing to manual handling, contact dermatitis can occur in professionals at any stage of the growth cycle of the tulip plant. To determine the clinical pattern of contact dermatitis resulting from tulip plant cultivation, and to assess contact allergy in workers coming into contact with this plant. One hundred and sixty-four tulip workers were screened, and 48 patients with suspected contact dermatitis were patch tested with 39 allergens, including haptens from the Indian baseline series, a plant series, and extracts from different parts of the tulip plant. Thirty-nine positive patch test reactions were observed in 21 patients. Seventeen patients showed positive reactions to either α-methylene-γ-butyrolactone or to tulip plant extract. Clinical relevance was observed for 13 of 17 positive patch test reactions. Contact dermatitis is an important health hazard in workers dealing with tulip bulbs. Further studies to identify and isolate other possible tulip allergens, and to quantify the amounts of allergens in different parts of the tulip plant, are recommended. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Occupational contact dermatitis to a limonene-based solvent in a histopathology technician.

    PubMed

    Foti, Caterina; Zambonin, Carlo G; Conserva, Anna; Casulli, Claudia; D'Accolti, Lucia; Angelini, Gianni

    2007-02-01

    Recently, D-limonene-based solvents are used as a safe alternative to xylene for histological and cytological application to dissolve paraffin. We report the case of a histopathology technician with a recalcitrant hand contact dermatitis strictly related to the use of a limonene-based solvent agent. Patch tests with SIDAPA (Italian Society of Allergological, Professional and Environmental Dermatology) standard series, limonene-based solvent used by the patient and D- and L-limonene (both oxidized and nonoxidized form) and with Giemsa and methylene blue stains were performed. Patch testing gave positive results to oxidized D- and L-limonene. The patient retired from work and promptly improved and healed the hand eczema. Subsequently, the potential occurrence of limonene oxidation products in the incriminated preparation was investigated using gas chromatography-mass spectrometry. While patch test showed positive reaction to oxidized limonene, chemical analysis failed to detect oxidized limonene in the preparations used by the patient. Considering the strict relation between the use of the preparations and the appearance of symptoms, we can assume that oxidized limonene may be produced during the handling of limonene-based products, especially in the presence of oxidants stains, frequently used in histological laboratories.

  13. Epidemic of Isothiazolinone Allergy in North America: Prevalence Data From the North American Contact Dermatitis Group, 2013-2014.

    PubMed

    Zirwas, Matthew J; Hamann, Dathan; Warshaw, Erin M; Maibach, Howard I; Taylor, James S; Sasseville, Denis; DeKoven, Joel G; Fransway, Anthony F; Mathias, C G Toby; Zug, Kathryn A; DeLeo, Vincent A; Fowler, Joseph F; Marks, James G; Pratt, Melanie D; Belsito, Donald V

    Preservative sensitivity patterns evolve with changing use patterns in products. During the last decade, the use of methylisothiazolinone (MI) at higher concentrations in both leave-on and rinse-off products has significantly increased. This is the first North American Contact Dermatitis Group reporting cycle that includes both methylchloroisothiazolinone (MCI)/MI and MI data. The aim of this study was to report the prevalence of isothiazolinone allergy (MCI/MI and MI) in the North American Contact Dermatitis Group patch-test population from January 1, 2013, to December 31, 2014. At 13 centers in North America, 4860 patients were patch tested in a standardized manner with a series of 70 allergens, including MCI/MI 0.01% aqueous (aq) and MI 0.2% aq. Three hundred five patients (6.3%) had a positive reaction to MCI/MI; this is a significant increase from the previous cycle (5.0%, 2011-2012; P = 0.011). Five hundred twenty-one patients (10.7%) had a positive reaction to MI. These 2 isothiazolinones were among the most common preservative allergens in the 2013 to 2014 cycle; 11.9% of patch-tested individuals were allergic to 1 or both isothiazolinones. Individuals with MCI/MI and MI allergy were significantly more likely to have occupationally related skin disease (P < 0.0001) and hand dermatitis (P < 0.0001, P = 0.0474). The epidemic of isothiazolinone sensitivity documented in Europe is now in North America. Patch testing with only MCI/MI 0.01% aq will miss approximately half of isothiazolinone allergy cases, whereas testing with only MI 0.2% aq will miss approximately 10% of isothiazolinone allergy cases.

  14. How does glaucoma look?: patient perception of visual field loss.

    PubMed

    Crabb, David P; Smith, Nicholas D; Glen, Fiona C; Burton, Robyn; Garway-Heath, David F

    2013-06-01

    To explore patient perception of vision loss in glaucoma and, specifically, to test the hypothesis that patients do not recognize their impairment as a black tunnel effect or as black patches in their field of view. Clinic-based cross-sectional study. Fifty patients (age range, 52-82 years) with visual acuity better than 20/30 and with a range of glaucomatous visual field (VF) defects in both eyes, excluding those with very advanced disease (perimetrically blind). Participants underwent monocular VF testing in both eyes using a Humphrey Field Analyzer (HFA; Carl Zeiss Meditec, Dublin, CA; 24-2 Swedish interactive threshold algorithm standard tests) and other tests of visual function. Participants took part in a recorded interview during which they were asked if they were aware of their VF loss; if so, there were encouraged to describe it in their own words. Participants were shown 6 images modified in a variety of ways on a computer monitor and were asked to select the image that most closely represented their perception of their VF loss. Forced choice of an image best representing glaucomatous vision impairment. Participants had a range of VF defect severity: average HFA mean deviation was -8.7 dB (standard deviation [SD], 5.8 dB) and -10.5 dB (SD, 7.1 dB) in the right and left eyes, respectively. Thirteen patients (26%; 95% confidence interval [CI], 15%-40%) reported being completely unaware of their vision loss. None of the patients chose the images with a distinct black tunnel effect or black patches. Only 2 patients (4%; 95% CI, 0%-14%) chose the image with a tunnel effect with blurred edges. An image depicting blurred patches and another with missing patches was chosen by 54% (95% CI, 39%-68%) and 16% (95% CI, 7%-29%) of the patients, respectively. Content analysis of the transcripts from the recorded interviews indicated a frequent use of descriptors of visual symptoms associated with reported blur and missing features. Patients with glaucoma do not perceive their vision loss as a black tunnel effect or as black patches masking their field of view. These findings are important in the context of depicting the effects of glaucomatous vision loss and raising awareness for glaucoma detection. The author(s) have no proprietary or commercial interest in any materials discussed in this article. Copyright © 2013 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  15. Is there an association between flow diverter fish mouthing and delayed-type hypersensitivity to metals?-a case-control study.

    PubMed

    Kocer, Naci; Mondel, Prabath Kumar; Yamac, Elif; Kavak, Ayse; Kizilkilic, Osman; Islak, Civan

    2017-11-01

    Flow diverters are increasingly used in the treatment of complex and giant intracranial aneurysms. However, they are associated with complications like late aneurysmal rupture. Additionally, flow diverters show focal structural decrease in luminal diameter without any intimal hyperplasia. This resembles a "fish mouth" when viewed en face. In this pilot study, we tested the hypothesis of a possible association between flow diverter fish-mouthing and delayed-type hypersensitivity to its metal constituents. We retrospectively reviewed patient records from our center between May 2010 and November 2015. A total of nine patients had flow diverter fish mouthing. A control group of 25 patients was selected. All study participants underwent prospective patch test to detect hypersensitivity to flow diverter metal constituents. Analysis was performed using logistic regression analysis and Wilcoxon sign rank sum test. Univariate and multivariate analyses were performed to test variables to predict flow diverter fish mouthing. The association between flow diverter fish mouthing and positive patch test was not statistically significant. In multivariate analysis, history of allergy and maximum aneurysm size category was associated with flow diverter fish mouthing. This was further confirmed on Wilcoxon sign rank sum test. The study showed statistically significant association between flow diverter fish mouthing and history of contact allergy and a small aneurysmal size. Further large-scale studies are needed to detect a statistically significant association between flow diverter fish mouthing and patch test. We recommend early and more frequent follow-up imaging in patients with contact allergy to detect flow diverter fish mouthing and its subsequent evolution.

  16. [Diagnostic workup of fragrance allergy].

    PubMed

    Geier, J; Uter, W

    2015-09-01

    The diagnostic workup of contact allergy to fragrances must not be limited to patch testing with the two well-established fragrance mixes. False-positive reactions to these mixes occur in up to 50 % of the patch tested patients. For the diagnostic work-up of positive reactions, and in cases of suspected fragrance allergy, patch testing with the single mix components and additional fragrances is mandatory. Frequently sensitizing fragrance materials are the 14 components of the two fragrance mixes and tree moss (Evernia furfuracea), ylang ylang oil (I + II; Cananga odorata), lemongrass oil (Cymbopogon schoenanthus), sandalwood oil (Santalum album), jasmine absolute (Jasminum spp.), and, less frequently, clove oil (Eugenia caryophyllus), cedarwood oil (Cedrus atlantica/deodara, Juniperus virginiana), Neroli oil (Citrus aurantium amara flower oil), salicylaldehyde, narcissus absolute (Narcissus spp.), and patchouli oil (Pogostemon cablin).

  17. Contact allergy in patients with rosacea: a clinic-based, prospective epidemiological study.

    PubMed

    Jappe, U; Schäfer, T; Schnuch, A; Uter, W

    2008-11-01

    Rosacea is a relatively common inflammatory skin disease of unknown prevalence. The proportion of contact allergy complicating rosacea and its therapy, respectively, is largely unknown. To estimate the prevalence of specific contact allergy in rosacea patients and to compare this with the prevalence observed in the general population and in general patch test patients. In this prospective monocentre study, 78 patients with rosacea were investigated for contact sensitizations via patch testing the standard series, constituents of topical formulations, preservatives, fragrances, topically applied drugs and, if available, patient's own products. Positive reactions occurred to nickel (II) sulphate (12 of 78, 15.4%), fragrance mix I (4 of 77, 5.2%), balsam of Peru (8 of 77, 10.4%; significantly elevated prevalence compared to that observed in the population-based KORA study), potassium dichromate (4 of 78, 5.1%) and Lyral (3 of 78, 3.8%). Regarding topical antibiotics, only 1 of 78 (1.3%) patients was positive to neomycin sulphate, and none to metronidazole; however, 6 of 75 (8%) patients were positive to gentamicin sulphate, and 4 of 76 (5.3%) patients were positive to framycetin sulphate. No allergic but irritant patch test reactions, instead, were provoked by various patients' own products as well as by the irritant sodium lauryl sulphate (SLS) even in low concentrations. Despite the limited power of the study, a strikingly high prevalence of contact allergy to gentamicin sulphate was observed, which is probably due to antibiotic treatment of rosacea-associated eye symptoms. The reactions to the irritant SLS probably mirror the extreme skin sensitivity in rosacea.

  18. Contact sensitivity to preservatives in Singapore: frequency of sensitization to 11 common preservatives 2006-2011.

    PubMed

    Cheng, Suzanne; Leow, Yung Hian; Goh, Chee Leok; Goon, Anthony

    2014-01-01

    Preservatives are indispensable agents used to prevent bacterial and fungal contamination of cosmetics, personal care products, domestic preparations, and industrial products. We evaluated patch-test data at the National Skin Centre, Singapore, from 2006 to 2011 to identify the trends in preservative contact allergies. All patients with suspected contact dermatitis were patch tested to 4 preservatives within the modified European standard series. Patients were also tested with 7 preservatives from our special series if clinically indicated. Three thousand one hundred seventy-seven patients were tested to preservatives in the standard series. Sensitization frequencies were all greater than 1%: parabens (2.58%), methylchloroisothiazolinone/methylisothiazolinone (1.75%), quaternium 15 (1.43%), and methyldibromoglutaronitrile (1.2%). There was no change in trends in sensitization frequencies from 2006 to 2011, with no increase in sensitization frequency to methylchloroisothiazolinone/methylisothiazolinone. The sensitization frequencies for methyldibromoglutaronitrile/phenoxyethanol and diazolidinylurea were 2.03% and 1.37%, respectively, and remained less than 1% for bronopol, imidazolidinyl urea, and 2-phenoxyethanol. A rate of 0% was seen for 1,3-dimethylol-5,5-dimethyl hydantoin and formaldehyde; 9.4% of positive patch-test results became positive only at day 7. Preservatives are common causes of allergic contact dermatitis. This should be considered when introducing new preservatives into the market. Day 7 readings are important to detect late reactions.

  19. Patch test results with fragrance markers of the baseline series - analysis of the European Surveillance System on Contact Allergies (ESSCA) network 2009-2012.

    PubMed

    Frosch, Peter J; Duus Johansen, Jeanne; Schuttelaar, Marie-Louise A; Silvestre, Juan F; Sánchez-Pérez, Javier; Weisshaar, Elke; Uter, Wolfgang

    2015-09-01

    Contact allergy to fragrances is common, and impairs quality of life, particularly in young women. To provide current results on the prevalences of sensitization to fragrance allergens used as markers in the baseline series of most European countries. Data of patients consecutively patch tested between 2009 and 2012 in 12 European countries with fragrance allergens contained in the baseline series were collected by the European Surveillance System on Contact Allergies network and descriptively analysed. Four departments used the TRUE Test(®) system. The 'basic markers' were tested on 51 477 [fragrance mix II (FM II)] to 57 123 [Myroxylon pereirae, balsam of Peru] patients, and yielded positive reactions as follows: fragrance mix I 6.9%, Myroxylon pereirae 5.4%, FM II 3.8%, colophonium 2.6%, and hydroxyisohexyl 3-cyclohexene carboxaldehyde 1.7%, with some regional differences. Prevalences with TRUE Test(®) allergens were lower. Additional fragrances were tested on 3643 (trimethylbenzenepropanol) to 14 071 (oil of turpentine) patients, and yielded between 2.6% (Cananga odorata) and 0.7% (trimethylbenzenepropanol) positive reactions. Contact allergy to fragrances is common throughout Europe, with regional variation probably being explained by patch test technique, and differences in exposure and referral patterns. The current basic markers of fragrance sensitivity in the baseline series should be supplemented with additional fragrance allergens. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Generalized reactions during skin testing with clindamycin in drug hypersensitivity: a report of 3 cases and review of the literature.

    PubMed

    Papakonstantinou, Eleni; Müller, Sabine; Röhrbein, Jan H; Wieczorek, Dorothea; Kapp, Alexander; Jakob, Thilo; Wedi, Bettina

    2018-04-01

    The diagnostic approach to drug hypersensitivity includes a detailed medical history, clinical examination, and skin testing and/or oral challenge with a culprit or alternative drug, depending on the type of reaction and the suspected drugs. Although skin testing is considered to be rather safe, cutaneous and systemic, including fatal, reactions have been described. To report 3 cases with generalized delayed reactions after skin testing with clindamycin, and to review the existing literature. Thorough clinical examination, blood tests and prick, intradermal and patch tests were performed in 3 patients. All patients experienced generalized maculopapular exanthema after intradermal and patch testing with clindamycin and amoxicillin in the first patient, and clindamycin alone in the second and third patient. None of the patients showed immediate reactions to skin tests, while positive intradermal reactions after 24 h to amoxicillin and clindamycin were observed in the first patient, and positive intradermal reactions after 24 h to clindamycin were observed in the second and third patients. Skin testing with clindamycin in the diagnosis of drug hypersensitivity carries some risk of adverse reactions. A stepwise and individual diagnostic work-up, considering potential risk factors, and testing in a specialized centre with emergency equipment available is highly recommended. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Patch test results in patients with allergic contact dermatitis in the Podlasie region

    PubMed Central

    Bacharewicz, Joanna; Pawłoś, Anna

    2013-01-01

    Introduction The aim of the study was to provide current data on the incidence of allergy to various contact allergens in patients with allergic contact eczema and the analysis of selected socio-demographic data of the patients. Material and methods The study included 1532 patients (1010 women and 522 men) treated for allergic contact dermatitis at the Department of Dermatology and Venereology and at the Dermatology Outpatient Clinic in Bialystok in 2007–2011. The assessment of selected demographic data and skin lesions was based on the MOAHFLA index, while the results of patch tests were analyzed with modified Baseline European Series consisting of 31 allergens. Results In the group of patients with eczema, 34.1% were men, and 55% of all respondents were people over 40 years of age. The occupational character of skin lesions was found in 22.5%. Most frequently (38.9%) skin lesions were localized on the hands, rarely involved legs (3.98%). Atopic dermatitis was diagnosed in 4.5% of patients. The ten most frequent allergens were: nickel sulfate (24%), cobalt chloride (15.3%), fragrance mix (8.25%), potassium dichromate (6.8%), balsam of Peru (5.5%), neomycin (4.42%), paraphenylenediamine (3.85%), Quatermium-15 (2.1%), detreomycin (1.83%) and budesonide (1.44% of tested patients). Conclusions Frequent allergy to detreomycin indicates the need of patch testing for this allergen of all examined patients with allergic contact dermatitis. The increased frequency of the nickel allergy is a worrying problem and indicates the need for education about the risk factors for nickel allergy development and the implementation of appropriate legal regulations. PMID:24493997

  2. Pragmatic approach to the clinical work-up of patients with putative allergic disease to metallic orthopaedic implants before and after surgery.

    PubMed

    Thyssen, J P; Menné, T; Schalock, P C; Taylor, J S; Maibach, H I

    2011-03-01

    Allergic complications following insertion of metallic orthopaedic implants include allergic dermatitis reactions but also extracutaneous complications. As metal-allergic patients and/or surgeons may ask dermatologists and allergologists for advice prior to planned orthopaedic implant surgery, and as surgeons may refer patients with complications following total joint arthroplasty for diagnostic work-up, there is a continuous need for updated guidelines. This review presents published evidence for patch testing prior to surgery and proposes tentative diagnostic criteria which clinicians can rely on in the work-up of patients with putative allergic complications following surgery. Few studies have investigated whether subjects with metal contact allergy have increased risk of developing complications following orthopaedic implant insertion. Metal allergy might in a minority increase the risk of complications caused by a delayed-type hypersensitivity reaction. At present, we do not know how to identify the subgroups of metal contact allergic patients with a potentially increased risk of complications following insertion of a metal implant. We recommend that clinicians should refrain from routine patch testing prior to surgery unless the patient has already had implant surgery with complications suspected to be allergic or has a history of clinical metal intolerance of sufficient magnitude to be of concern to the patient or a health provider. The clinical work-up of a patient suspected of having an allergic reaction to a metal implant should include patch testing and possibly in vitro testing. We propose diagnostic criteria for allergic dermatitis reactions as well as noneczematous complications caused by metal implants. © 2011 The Authors. BJD © 2011 British Association of Dermatologists.

  3. The fragrance mix and its constituents: a 14-year material.

    PubMed

    Johansen, J D; Menné, T

    1995-01-01

    Results from 14 years of patch testing with the fragrance mix and its constituents are reviewed. From 1979-1992, 8215 consecutive patients were patch tested with the fragrance mix and 449 (5.5%) had a positive reaction. An increase in the frequency of reactions to fragrance mix was seen from the first 5-year period to the last. Only 54.4% of the patients tested in the last 5-year period with the individual constituents of the mix had at least 1 positive reaction. The results of testing with the constituents are the basis for a discussion of methodological problems. A significant decrease in the frequency of reaction to cinnamic aldehyde was registered, at the same time as the test concentration was reduced from 2% to 1% pet. However, no significant variations in the frequency of reactions to oak moss were seen, notwithstanding a similar reduction in test concentration.

  4. Cross-reactions to desoximetasone and mometasone furoate in a patient with multiple topical corticosteroid allergies.

    PubMed

    Donovan, Jeffrey C H; Dekoven, Joel G

    2006-09-01

    A 60-year-old man developed a bullous contact dermatitis after topical corticosteroid treatment of dermatitis on his lower leg. Subsequent patch testing showed cross-reactions to numerous group B and group D corticosteroids as well as cross-reactions to group C desoximetasone and group D1 mometasone furoate. His patch-test result was negative for the group A corticosteroids hydrocortisone and tixocortol pivalate. We discuss the uncommon finding of cross-reactions to desoximetasone and mometasone furoate.

  5. Epidemiological data on airborne contact dermatitis - results of the IVDK.

    PubMed

    Breuer, Kristine; Uter, Wolfgang; Geier, Johannes

    2015-10-01

    Airborne contact dermatitis (AirbCD) is not uncommon, according to a large number of published case reports and review articles. Epidemiological data on AirbCD based on larger clinical samples have not yet been published. To investigate demographic characteristics and patch test reactivity in patients diagnosed with both occupational and non-occupational AirbCD. A retrospective analysis of data from the Information Network of Departments of Dermatology (IVDK), 1994-2013, including 201 344 consecutively patch tested patients, was performed. One thousand two hundred and three patients (0.6%) were diagnosed with AirbCD, 421 (35.0%) of these with an occupational background. Occupational dermatitis and face involvement were more prevalent than in patients without AirbCD (n = 200 141). Sensitization to epoxy resin and sensitization to methylchloroisothiazolinone (MCI)/methylisothiazolinone (MI) were significantly associated with AirbCD, and there was a trend for sensitization to Compositae mix and/or sesquiterpene lactone mix to be associated with AirbCD. Adhesives, plastics, construction materials, paints and varnishes in occupational cases, and plants in non-occupational cases, were the most commonly documented culprit product categories. AirbCD is more common in patients with occupational dermatitis than in patients with non-occupational dermatitis. In our clinical sample, components of epoxy resin systems, MCI/MI and Compositae allergens were the most important contact allergens associated with AirbCD. Patch testing with additional allergens is important. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. The MOAHLFA index of irritant sodium lauryl sulfate reactions: first results of a multicentre study on routine sodium lauryl sulfate patch testing.

    PubMed

    Uter, Wolfgang; Geier, Johannes; Becker, Detlef; Brasch, Jochen; Löffler, Harald

    2004-01-01

    In a multicentre study of the German Contact Dermatitis Research Group, sodium lauryl sulfate (SLS) 0.25% and 0.5% aq. has been added to routine allergen patch tests to assess its properties as a convenient diagnostic indicator of individual susceptibility to irritation at the time of patch testing. Previous studies indicated that irritant SLS reactivity may be related to individual factors such as age and sex. As these factors are, in turn, among the important predictors of contact allergy to many allergens, e.g. summarized in the 'MOAHLFA index', the impact of the MOAHLFA factors on irritant SLS patch test reactivity, and thus a potential for confounding, was assessed in the 5971 participating patients. As a result of 2 logistic regression analyses with an irritant reaction to 0.25% and 0.5% SLS, respectively, as outcome, male sex was identified as a relatively weak but significant risk factor (OR 1.38), while age 40 years or older was an even weaker risk factor (OR 1.22 and 1.15, respectively). Upon detailed analysis, no clear age gradient could, however, be identified. 1-day exposure time almost halved the odds of an irritant SLS reaction. In conclusion, this type of SLS patch test can be regarded as robust, indicating individual irritability relatively independent from the individual factors analysed here.

  7. Frequency of positive patch test reactions to preservatives: The Australian experience.

    PubMed

    Chow, Elizabeth T; Avolio, Andrea M; Lee, Adriene; Nixon, Rosemary

    2013-02-01

    Preservatives are important causes of allergic contact dermatitis. The frequency of allergy to preservatives in Australia has been unknown to date. Our objectives are to report the frequency of positive preservative patch test reactions in Australia, comparing them to the published international data, as well as exploring the current regulations in place for preservative use in Australia. This was the first retrospective study of patch testing results, aggregated from four patch test clinics in three centres in Melbourne and Sydney. In all, 6845 patients were patch-tested during 1993-2006 and in this period the five most frequent preservative allergens were formaldehyde (4.6%), Euxyl K400 (containing methyldibromo glutaronitrile and phenoxyethanol) (3.3%), quaternium-15 (2.9%), diazolidinyl urea (2.4%), and methylchloroisothiazolinone/methylisothiazolinone (2.3%). These were followed by dimethylol dimethyl DMDM hydantoin (2.1%), chloroacetamide (2.1%) and imidazolidinyl urea (1.9%). The least frequent sensitisers were parabens (1.1%), 2-bromo-2-nitropropane-1, 3-diol (0.9%) and benzyl alcohol (0.4%). Formaldehyde was the most prevalent preservative allergen. Chloroacetamide allergy was more commonly seen in Australia. Parabens, 2-bromo-2-nitropropane-1,3-diol and benzyl alcohol were the least frequent sensitisers. Household products in Australia are not required to list all ingredients preventing sensitised individuals from properly assessing their exposure. © 2012 The Authors Australasian Journal of Dermatology © 2012 The Australasian College of Dermatologists.

  8. Treatment of Neuropathic Pain with the Capsaicin 8% Patch: Is Pretreatment with Lidocaine Necessary?

    PubMed Central

    Kern, Kai-Uwe; Nowack, Walburga; Poole, Chris

    2014-01-01

    The capsaicin 8% patch can effectively treat neuropathic pain, but application can cause discomfort or a burning sensation. Until March 2013, it was recommended that patients be pretreated with a topical anesthetic, for example lidocaine, before capsaicin patch application. However, speculation existed over the need for pretreatment and its effectiveness in alleviating treatment-associated discomfort. This article compares tolerability to and efficacy of the capsaicin patch in pretreated and non-pretreated patients. All patients received a single capsaicin patch application. Pretreated patients received a lidocaine plaster before and intravenous lidocaine and metamizole infusions during capsaicin patch application. Pain levels, assessed using a Numeric Rating Scale (NRS), were used to determine tolerability and efficacy. All patients (pretreated n = 32; non-pretreated n = 26) completed 100% of the intended capsaicin patch application duration. At the time of capsaicin patch removal, 69% of pretreated and 88% of non-pretreated patients reported an NRS score increase, which returned to baseline by 6 hours post-treatment. There was no significant difference in mean NRS score between patient groups at any time during or after capsaicin patch treatment. Response was similar between patient groups; capsaicin patch treatment provided rapid and significant pain reductions that were sustained over 12 weeks. The same proportion of pretreated and non-pretreated patients reported willingness to receive retreatment with the capsaicin patch. This analysis shows that the capsaicin 8% patch is generally tolerable, and the small discomfort associated with patch application is short-lived. Lidocaine pretreatment does not have a significant effect on tolerability, efficacy, or patient willingness to receive retreatment. PMID:24289500

  9. Patch-testing for the management of hypersensitivity reactions to second-line anti-tuberculosis drugs: a case report.

    PubMed

    Khan, Samsuddin; Andries, Aristomo; Pherwani, Asha; Saranchuk, Peter; Isaakidis, Petros

    2014-08-15

    The second-line anti-tuberculosis drugs used in the treatment of multidrug-resistant tuberculosis often cause adverse events, especially in patients co-infected with the human immunodeficiency virus. Severe hypersensitivity reactions due to these drugs are rare and there is little published experience to guide their management. A 17-year old Indian female multidrug-resistant tuberculosis patient co-infected with human immunodeficiency virus developed a hypersensitivity reaction after starting second-line anti-tuberculosis treatment in Mumbai, India. The patient was being treated with kanamycin, moxifloxacin, para-aminosalicylic acid, cycloserine, clofazimine, and amoxicillin-clavulanic acid. Twenty-four hours later, the patient developed generalized urticaria, morbilliform rash and fever. All drugs were suspended and the patient was hospitalised for acute management. Skin patch-testing was used to identify drugs that potentially caused the hypersensitivity reaction; results showed a strong reaction to clofazimine, moderate reaction to kanamycin and mild reaction to cycloserine. An interim second-line anti-tuberculosis regimen was prescribed; cycloserine and kanamycin were then re-challenged one-by-one using incremental dosing, an approach that allowed clinicians to re-introduce these drugs promptly and safely. The patient is currently doing well. This is the first case-report of a multidrug-resistant tuberculosis patient co-infected with the human immunodeficiency virus with hypersensitivity reaction to multiple second-line anti-tuberculosis drugs. Skin patch-testing and controlled re-challenge can be a useful management strategy in such patients. There is an urgent need for second-line anti-tuberculosis regimens that are more effective, safe and better tolerated.

  10. Association between cobalt allergy and dermatitis caused by leather articles--a questionnaire study.

    PubMed

    Bregnbak, David; Thyssen, Jacob P; Zachariae, Claus; Menné, Torkil; Johansen, Jeanne D

    2015-02-01

    Cobalt is a strong skin sensitizer and a prevalent contact allergen. Recent studies have recognized exposure to leather articles as a potential cause of cobalt allergy. To examine the association between contact allergy to cobalt and a history of dermatitis resulting from exposure to leather. A questionnaire case-control study was performed: the case group consisted of 183 dermatitis patients with a positive patch test reaction to cobalt chloride and a negative patch test reaction to potassium dichromate; the control group consisted of 621 dermatitis patients who did not react to either cobalt or chromium in patch testing. Comparisons were made by use of a χ(2) -test, Fisher's exact, and the Mann-Whitney test. Logistic regression analyses were used to test for associations while taking confounding factors into consideration. Leather was observed as the most frequent exposure source causing dermatitis in the case group. Although the case group significantly more often reported non-occupational dermatitis caused by leather exposure (p < 0.001), no association was found between cobalt allergy and dermatitis caused by work-related exposure to leather. Our study suggests a positive association between cobalt allergy and a history of dermatitis caused by non-occupational exposure to leather articles. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Patch testing in children from 2005 to 2012: results from the North American contact dermatitis group.

    PubMed

    Zug, Kathryn A; Pham, Anh Khoa; Belsito, Donald V; DeKoven, Joel G; DeLeo, Vincent A; Fowler, Joseph F; Fransway, Anthony F; Maibach, Howard I; Marks, James G; Mathias, C G Toby; Pratt, Melanie D; Sasseville, Denis; Storrs, Frances J; Taylor, James S; Warshaw, Erin M; Zirwas, Matthew J

    2014-01-01

    Allergic contact dermatitis is common in children. Epicutaneous patch testing is an important tool for identifying responsible allergens. The objective of this study was to provide the patch test results from children (aged ≤18 years) examined by the North American Contact Dermatitis Group from 2005 to 2012. This is a retrospective analysis of children patch-tested with the North American Contact Dermatitis Group 65- or 70-allergen series. Frequencies and counts were compared with previously published data (2001-2004) using χ statistics. A total of 883 children were tested during the study period. A percentage of 62.3% had ≥1 positive patch test and 56.7% had ≥1 relevant positive patch test. Frequencies of positive patch test and relevant positive patch test reaction were highest with nickel sulfate (28.1/25.6), cobalt chloride (12.3/9.1), neomycin sulfate (7.1/6.6), balsam of Peru (5.7/5.5), and lanolin alcohol 50% petrolatum vehicle (5.5/5.1). The ≥1 positive patch test and ≥1 relevant positive patch test in the children did not differ significantly from adults (≥19 years) or from previously tested children (2001-2004). The percentage of clinically relevant positive patch tests for 27 allergens differed significantly between the children and adults. A total of 23.6% of children had a relevant positive reaction to at least 1 supplemental allergen. Differences in positive patch test and relevant positive patch test frequencies between children and adults as well as test periods confirm the importance of reporting periodic updates of patch testing in children to enhance clinicians' vigilance to clinically important allergens.

  12. Principles and methodology for identification of fragrance allergens in consumer products.

    PubMed

    Gimenez-Arnau, A; Gimenez-Arnau, E; Serra-Baldrich, E; Lepoittevin, J-P; Camarasa, J G

    2002-12-01

    Fragrances contain several hundreds of different chemicals, a few major and many minor, which are responsible for the complexity of the odour. Fragrances are a major cause of allergic contact dermatitis. As a diagnostic tool, the current fragrance mix is very useful though not ideal. A 50-year-old woman presented with a pruriginous, erythematous eruption, characterized by papules, vesicles, exudation and crusting over the neck and chest. With the suspicion of fragrance allergy, patch testing was performed. Initially, the only positive reaction observed was with her own eau de toilette named Woman. The TRUE Test fragrance mix patch test was negative. Chemical fractionation of Woman perfume concentrate was combined with a sequenced patch testing procedure and with structure-activity relationship studies. Ingredients supplied by the manufacturer were also included in the study. Benzophenone-2, Lyral, alpha-hexyl cinnamic aldehyde and alpha-damascone were found to be responsible for the patient's contact allergy to the commercial product. These substances contain chemical structural alerts giving them antigenic ability. The common use of new chemicals to manufacture fragrances, and the increased number of patients sensitive to them but with negative fragrance mix reactions, makes it necessary to identify new potential fragrance sensitizers in commercial products.

  13. Surgery for left ventricular aneurysm: early and late survival after simple linear repair and endoventricular patch plasty.

    PubMed

    Lundblad, Runar; Abdelnoor, Michel; Svennevig, Jan Ludvig

    2004-09-01

    Simple linear resection and endoventricular patch plasty are alternative techniques to repair postinfarction left ventricular aneurysm. The aim of the study was to compare these 2 methods with regard to early mortality and long-term survival. We retrospectively reviewed 159 patients undergoing operations between 1989 and 2003. The epidemiologic design was of an exposed (simple linear repair, n = 74) versus nonexposed (endoventricular patch plasty, n = 85) cohort with 2 endpoints: early mortality and long-term survival. The crude effect of aneurysm repair technique versus endpoint was estimated by odds ratio, rate ratio, or relative risk and their 95% confidence intervals. Stratification analysis by using the Mantel-Haenszel method was done to quantify confounders and pinpoint effect modifiers. Adjustment for multiconfounders was performed by using logistic regression and Cox regression analysis. Survival curves were analyzed with the Breslow test and the log-rank test. Early mortality was 8.2% for all patients, 13.5% after linear repair and 3.5% after endoventricular patch plasty. When adjusted for multiconfounders, the risk of early mortality was significantly higher after simple linear repair than after endoventricular patch plasty (odds ratio, 4.4; 95% confidence interval, 1.1-17.8). Mean follow-up was 5.8 +/- 3.8 years (range, 0-14.0 years). Overall 5-year cumulative survival was 78%, 70.1% after linear repair and 91.4% after endoventricular patch plasty. The risk of total mortality was significantly higher after linear repair than after endoventricular patch plasty when controlled for multiconfounders (relative risk, 4.5; 95% confidence interval, 2.0-9.7). Linear repair dominated early in the series and patch plasty dominated later, giving a possible learning-curve bias in favor of patch plasty that could not be adjusted for in the regression analysis. Postinfarction left ventricular aneurysm can be repaired with satisfactory early and late results. Surgical risk was lower and long-term survival was higher after endoventricular patch plasty than simple linear repair. Differences in outcome should be interpreted with care because of the retrospective study design and the chronology of the 2 repair methods.

  14. Allergic contact dermatitis from the synthetic fragrances Lyral and acetyl cedrene in separate underarm deodorant preparations.

    PubMed

    Handley, J; Burrows, D

    1994-11-01

    The case is reported of a 28-year-old man who developed allergic contact dermatitis from 2 synthetic fragrance ingredients, Lyral (3- and 4-(4-hydroxy-4-methylpentyl)-3-cyclohexene-1-aldehyde) and acetyl cedrene, in separate underarm deodorant preparations. The implications of the patient's negative patch test reactions to the European standard series (Trolab) and cosmetics and fragrance series (both Chemotechnique Diagnostics) are discussed. The importance is stressed of patch testing with the patient's own preparations when cosmetic dermatitis is suspected, and of identifying and reporting offending fragrance ingredients, with a view possibly to updating the European standard series and commercially available cosmetics and fragrance series.

  15. Allergic contact reaction to dexpanthenol: lymphocyte transformation test and evidence for microsomal-dependent metabolism of the allergen.

    PubMed

    Hahn, C; Röseler, S; Fritzsche, R; Schneider, R; Merk, H F

    1993-02-01

    In a patient with contact dermatitis, dexpanthenol was found to be the causative allergen. There was a positive reaction to dexpanthenol on patch testing. Controls did not show any positive reactions to dexpanthenol on patch testing. Additionally, an LTT was performed. After preincubation with dexpanthenol-modified microsomes, we observed an increase in lymphocyte proliferation to dexpanthenol, in comparison to dexpanthenol without microsomes, suggesting that microsomal metabolism plays a rôle in the pathogenesis of dexpanthenol sensitization, because microsomes are known to possess drug metabolizing enzymes such as cytochrome P450.

  16. Patch tests with fragrance mix II and its components.

    PubMed

    Pónyai, Györgyi; Németh, Ilona; Altmayer, Anita; Nagy, Gabriella; Irinyi, Beatrix; Battyáni, Zita; Temesvári, Erzsébet

    2012-01-01

    Fragrance mix II (FM II) was initiated to detect contact hypersenstitivity (CH) to fragrances that could not have been identified previously. The aim of this multicenter study was to map the frequency of CH to FM II and its components in Hungary. Six centers participated in the survey from 2009 to 2010. A total off 565 patients (434 women and 131 men) with former skin symptoms provoked by scented products were patch tested. The tests were performed with Brial GmbH D-Greven allergens. In the environmental patch test series, FM II, FM I, Myroxylon pereirae, colophonium, wood-tar mix, propolis, and sesquiterpene lactone mix were tested as fragrance allergens. The FM II components (citral, farnesol, coumarin, citronellol, α-hexyl-cinnamaldehyde, and hydroxy-isohexyl-3-cyclohexene-carboxaldehyde [Lyral]) were also tested. Contact hypersenstitivity to any fragrances was detected in 28.8%, to FM II in 17.2% of the patients. Contact hypersenstitivity to hydroxy-isohexyl-3-cyclohexene-carboxaldehyde was observed in 7.3%, to coumarin in 5.1%, to α-hexyl-cinnamaldehyde in 3.5%, to citral in 3.4%, to farnesol in 2.5%, and to citronellol in 1.2%. Of the FM II-positive cases, 48.4% showed isolated CH reaction. The frequency of CH to FM II is 17.2% in the tested, selected Hungarian population. The CH to FM II and its components could not have been revealed without the present test materials.

  17. Fragrance mix II in the baseline series contributes significantly to detection of fragrance allergy.

    PubMed

    Heisterberg, Maria V; Andersen, Klaus E; Avnstorp, Christian; Kristensen, Berit; Kristensen, Ove; Kaaber, Knud; Laurberg, Grete; Menné, Torkil; Nielsen, Niels Henrik; Sommerlund, Mette; Thormann, Jens; Veien, Niels K; Vissing, Susanne; Johansen, Jeanne D

    2010-11-01

    Fragrance mix II (FM II) is a relatively new screening marker for fragrance contact allergy. It was introduced in the patch test baseline series in Denmark in 2005 and contains six different fragrance chemicals commonly present in cosmetic products and which are known allergens. To investigate the diagnostic contribution of including FM II in the baseline series by comparing it with other screening markers of fragrance allergy: fragrance mix I (FM I), Myroxylon pereirae and hydroxyisohexyl 3-cyclohexene carboxaldehyde (HICC). Retrospective study of 12 302 patients consecutively patch tested with FM II by members of the Danish Contact Dermatitis Group 2005-2008. FM II gave a positive patch test in 553 patients (4.5%), and in 72.2% of these patients the reaction was judged to be clinically relevant. FM II ranked second in detecting fragrance allergy, after FM I. If FM II had not been included as a screening marker in the baseline series, 15.6% (n = 202) of individuals with fragrance allergy would not have been identified by the other fragrance screening markers (FM I, M. pereirae or HICC). FM II contributes substantially to detecting fragrance allergy. It ranked second among the fragrance screening markers tested in the baseline series and detects individuals with an allergy who otherwise would not have been identified. © 2010 John Wiley & Sons A/S.

  18. Clinical relevance of positive patch test reactions to the 26 EU-labelled fragrances.

    PubMed

    van Oosten, Eleonoor J; Schuttelaar, Marie-Louise A; Coenraads, Pieter Jan

    2009-10-01

    Fragrance mix I (FM I) and fragrance mix II (FM II) in the European baseline series are used as screening tools for fragrance contact allergy. In 2005 the European Union (EU) required labelling of 26 fragrances when present in cosmetic products. INCI nomenclature is obligatory for such labelling. To describe frequencies of contact allergy to these 26 fragrance substances, and to evaluate clinical relevance of these positive reactions. Three hundred and twenty patients with eczema suspected of being contact allergy to fragrances or cosmetics were patch tested with the EU-declared fragrance chemicals, FM I and FM II. There were 76 positive reactions in 33 patients. Most reactions were seen to [corrected] hydroxyisohexyl 3-cyclohexene carboxaldehyde in 3.1%, followed by Evernia furfuracea (2.5%) and cinnamyl alcohol (2.5%). Twelve reactions to FM I and II were not confirmed by separate ingredients. Clinical relevance of positive reactions to fragrances was certain in 20/33 (61%). 10.3% of the patients had positive patch tests in the EU-list. Hydroxyisohexyl 3-cyclohexene carboxaldehyde, a component of FM II, was the most frequent allergen, followed by Evernia furfuracea. Since Evernia furfuracea is not part of FM I or FM II, relevant reactions can be missed when only the European baseline series is used.

  19. Eosinophilic airway disease in a patient with a negative skin prick test, but a positive patch test with platinum salts--implications for medical surveillance.

    PubMed

    Merget, Rolf; Fartasch, Manigé; Sander, Ingrid; Van Kampen, Vera; Raulf, Monika; Brüning, Thomas

    2015-09-01

    We present the case of a 52-year-old woman with a topic dermatitis since adolescence who developed work-related hand eczema, cough and runny nose 12 years after she had started working as a laboratory technician at a precious metals refinery. While skin prick test with sodium hexachloroplatinate (SPTPt ) was negative, patch testing with ammonium tetrachloroplatinate was positive after 24, 48, 72, and 96 hr. Inhalation challenge with sodium hexachloroplatinate yielded cough, mild shortness of breath, and a maximal decrease of FEV1 of 8% from baseline 24 hr after the challenge. Significant increases of bronchial hyperresponsiveness, exhaled nitric monoxide and sputum eosinophils were documented after the challenge. We conclude that eosinophilic airway disease due to platinum salts may occur in SPTPt negative subjects. Both, patch testing and inhalation challenge with platinum salts should be considered in SPT negative subjects with occupational exposure to precious metal salts and work-related allergic symptoms. © 2015 Wiley Periodicals, Inc.

  20. Lidocaine patches reduce pain in trauma patients with rib fractures.

    PubMed

    Zink, Karen A; Mayberry, John C; Peck, Ellen G; Schreiber, Martin A

    2011-04-01

    Rib fracture pain is notoriously difficult to manage. The lidocaine patch is effective in other pain scenarios with an excellent safety profile. This study assesses the efficacy of lidocaine patches for treating rib fracture pain. A prospectively gathered cohort of patients with rib fracture was retrospectively analyzed for use of lidocaine patches. Patients treated with lidocaine patches were matched to control subjects treated without patches. Subjective pain reports and narcotic use before and after patch placement, or equivalent time points for control subjects, were gathered from the chart. All patients underwent long-term follow-up, including a McGill Pain Questionnaire (MPQ). Twenty-nine patients with lidocaine patches (LP) and 29 matched control subjects (C) were analyzed. During the 24 hours before patch placement, pain scores and narcotic use were similar (LP 5.3, C 4.6, P = 0.19 and LP 51, C 32 mg morphine, P = 0.17). In the 24 hours after patch placement, LP patients had a greater decrease in pain scores (LP 1.2, C 0.0, P = 0.01) with no change in narcotic use (LP -8.4, C 0.5-mg change in morphine, P = 0.25). At 60 days, LP patients had a lower MPQ pain score (LP 7.7, C 12.2, P < 0.01), although only one patient was still using a patch. There was no difference in time to return to baseline activity (LP 73, C 105 days, P = 0.16) and no adverse events. Lidocaine patches are a safe, effective adjunct for rib fracture pain. Lidocaine patches resulted in a sustained reduction in pain, outlasting the duration of therapy.

  1. Aortic valve repair with autologous pericardial patch.

    PubMed

    Lausberg, Henning F; Aicher, Diana; Langer, Frank; Schäfers, Hans-Joachim

    2006-08-01

    Isolated aortic valve repair (AVR) has been gaining increasing interest in recent times. Results of isolated aortic valve repair have been reported to be variable. Various techniques have been utilized. We analyzed our experience with isolated valve repair using autologous pericardial patch plasty and compared the results to an age-matched collective with aortic valve repair without the use of additional material. Between January 1997 and June 2005, pericardial patch plasty of the aortic valve was performed in 42 patients (PATCH). During the same period, 42 patients after AVR without the use of additional material were age matched (NO-PATCH). Mean age in both groups was 52 years with a majority of male patients (PATCH ratio, 3.7:1; NO-PATCH ratio, 5:1). Valve anatomy was similar in both groups. All patients were followed by echocardiography for a cumulative follow-up of 2341 patient months (mean 28+/-23 months). No patient died in the hospital in neither group. The average systolic gradient was 5.9+/-2.2 mmHg in PATCH and 4.8+/-2.1 mmHg in NO-PATCH; p=0.17). Freedom from aortic regurgitation > or = II degrees was 87.8% in PATCH and 95.0% in NO-PATCH after 5 years (p=0.21). Freedom from reoperation was 97.6% in PATCH and 97.4% in NO-PATCH (p=0.96). Aortic regurgitation can be treated effectively by aortic valve repair using pericardial patch plasty. The functional results are satisfactory. With the application of this technique also more complex pathologies of the aortic valve can be addressed adequately thus extending the concept of valve preservation in patients with aortic regurgitation.

  2. Quality of life in patients with allergic contact dermatitis.

    PubMed

    Kadyk, Deana L; McCarter, Kevin; Achen, Fritz; Belsito, Donald V

    2003-12-01

    Allergic contact dermatitis (ACD), a common dermatological disorder, often results in ongoing disease and disability. However, relatively little has been published quantifying the quality of life (QoL) of patients with ACD. This study was conducted to investigate the impact of ACD on QoL and explore prognostic factors that influence outcomes. A total of 428 subjects with ACD were, at varying times after diagnosis, mailed a QoL questionnaire modified from Skindex-16 to include an additional 5 items pertaining to occupational impact. The QoL scores were correlated with subject demographics, disease characteristics, and management techniques to ascertain factors that impact QoL in subjects with ACD. The response rate was 35%, with 149 subjects returning the postal survey. Responders reported being bothered most by itching, skin irritation, and persistence of the condition. Of the four scales included in the QoL questionnaire, the emotions scale had the worst composite QoL score, followed by symptoms, functioning, and occupational impact. Patients with ACD of the face were significantly more bothered by the appearance of their skin. Hand involvement and occupationally related ACD were associated with worse QoL scores within the occupational impact and functioning scales. Subjects that had changed jobs because of ACD had more severe QoL impairment than any other group analyzed, with significantly worse scores on 17 of the 21 QoL items. A history of atopic eczema seemed to impart improved outcomes on patients with ACD, and these subjects were less worried about being fired from their jobs. Subjects diagnosed by patch testing more than 36 months after disease onset seemed to have worse QoL scores than those diagnosed earlier in the natural history of the disease. Patients diagnosed by patch testing within the last 6 months had the worst QoL scores, while the best outcomes were reported in subjects patch tested 6 to 12 months ago. A slight decline in QoL was observed 12 months after patch testing, but scores did not diminish back to the level seen immediately after diagnosis. ACD has an appreciable effect on QoL, especially when it affects the hands, the face, or is occupationally related. Of the four scales included in our study, the emotions scale suffered the greatest effect. Emotional impact is therefore an important measure of QoL in ACD patients. Outcomes in patients with ACD were improved by early diagnosis and subjects enjoyed their best QoL at 6 to 12 months after patch testing. However, individuals who elected to change jobs because of their skin condition reported significantly worse QoL than those who retained their current positions.

  3. Contact Dermatitis for the Practicing Allergist.

    PubMed

    Bernstein, David I

    2015-01-01

    This article provides an overview of important practice recommendations from the recently updated Contact Dermatitis Practice Parameter. This updated parameter provides essential recommendations pertaining to clinical history, physical examination, and patch testing evaluation of patients suspected of allergic contact dermatitis. In addition to providing guidance for performing and interpreting closed patch testing, the updated parameter provides concrete recommendations for assessing metal hypersensitivity in patients receiving prosthetic devices, for evaluating workers with occupational contact dermatitis, and also for addressing allergic contact dermatitis in children. Finally, the document provides practical recommendations useful for educating patients regarding avoidance of exposure to known contact sensitizers in the home and at work. The Contact Dermatitis Parameter is designed as a practical, evidence-based clinical tool to be used by allergists and dermatologists who routinely are called upon to evaluate patients with skin disorders. Copyright © 2015 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  4. Nickel, palladium and rhodium induced IFN-gamma and IL-10 production as assessed by in vitro ELISpot-analysis in contact dermatitis patients

    PubMed Central

    Bordignon, Valentina; Palamara, Francesca; Cordiali-Fei, Paola; Vento, Antonella; Aiello, Arianna; Picardo, Mauro; Ensoli, Fabrizio; Cristaudo, Antonio

    2008-01-01

    Background Recent attempts to diminish nickel use in most industrial products have led to an increasing utilization of alternative metal compounds for destinations such as the alloys used in orthopaedics, jewellery and dentistry. The present study was undertaken with the aim to evaluate the potential for an allergic response to nickel, palladium and rhodium on the basis of antigen-specific induction of inflammatory/regulatory cytokines, and to characterize, according to the cytokine profiles, the nature of simultaneous positive patch tests elicited in vivo. Peripheral blood mononuclear cells (PBMC) from 40 patients with different patch test results were kept in short term cultures in the presence of optimized concentrations of NiSO4 × 6H2O, PdCl2 and Rh(CH3COO)2. The production of IFN-γ and IL-10 elicited by metal compounds were analyzed by the ELISpot assay. Results We found a specific IFN-γ response by PBMC upon in vitro stimulation with nickel or palladium in well recognized allergic individuals. All controls with a negative patch test to a metal salt showed an in vitro IL-10 response and not IFN-γ production when challenged with the same compound. Interestingly, all subjects with positive patch test to both nickel and palladium (group 3) showed an in vitro response characterized by the release of IFN-γ after nickel stimulation and production of IL-10 in response to palladium. Conclusion These results strongly suggest that the different cytokine profiles elicited in vitro reflect different immune responses which may lead to the control of the allergic responses or to symptomatic allergic contact dermatitis. The development of sensitive and specific in vitro assays based on the determination of the cytokine profiles in response to contact allergens may have important diagnostic and prognostic implications and may prove extremely useful in complementing the diagnostic limits of traditional patch testing. PMID:18482439

  5. The potential utility of iodinated contrast media (ICM) skin testing in patients with ICM hypersensitivity.

    PubMed

    Ahn, Young-Hwan; Koh, Young-Il; Kim, Joo-Hee; Ban, Ga-Young; Lee, Yeon-Kyung; Hong, Ga-Na; Jin, U-Ram; Choi, Byung-Joo; Shin, Yoo-Seob; Park, Hae-Sim; Ye, Young-Min

    2015-03-01

    Both immediate and delayed hypersensitivity reactions to iodinated contrast media (ICM) are relatively common. However, there are few data to determine the clinical utility of immunologic evaluation of ICM. To evaluate the utility of ICM skin testing in patients with ICM hypersensitivity, 23 patients (17 immediate and 6 delayed reactions) were enrolled from 3 university hospitals in Korea. With 6 commonly used ICM including iopromide, iohexol, ioversol, iomeprol, iopamidol and iodixanol, skin prick (SPT), intradermal (IDT) and patch tests were performed. Of 10 patients with anaphylaxis, 3 (30.0%) and 6 (60.0%) were positive respectively on SPTs and IDTs with the culprit ICM. Three of 6 patients with urticaria showed positive IDTs. In total, 11 (64.7%) had positive on either SPT or IDT. Three of 6 patients with delayed rashes had positive response to patch test and/or delayed IDT. Among 5 patients (3 anaphylaxis, 1 urticaria and 1 delayed rash) taken subsequent radiological examinations, 3 patients administered safe alternatives according to the results of skin testing had no adverse reaction. However, anaphylaxis developed in the other 2 patients administered the culprit ICM again. With 64.7% (11/17) and 50% (3/6) of the sensitivities of corresponding allergic skin tests with culprit ICM for immediate and delayed hypersensitivity reactions, the present study suggests that skin tests is useful for the diagnosis of ICM hypersensitivity and for selecting safe ICM and preventing a recurrence of anaphylaxis caused by the same ICM.

  6. Surgery-Related Contact Dermatitis: A Review of Potential Irritants and Allergens.

    PubMed

    Cook, Kevin A; Kelso, John M

    Surgical procedures utilize an increasing number of medical products including antiseptics, anesthetics, gloves, suture materials, tissue adhesives, topical antibiotics, and bandages. Many of these products have irritant potential. Allergic contact dermatitis has also been reported. This review covers preoperative, operative, and postoperative exposures that may result in contact dermatitis. Testing with standard patch panels such as T.R.U.E. Test and the North American Contact Dermatitis Group 65 allergen series does not evaluate for all relevant contactants. A thorough understanding of potential exposures is vital to effectively evaluate a patient with surgery-related contact dermatitis. A systematic approach is needed to ensure that standard patch panels and supplementary patches adequately address each encountered contactant. Copyright © 2017 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  7. Multicentre study of fragrance allergy in Hungary. Immediate and late type reactions.

    PubMed

    Temesvári, Erzsébet; Németh, Ilona; Baló-Banga, Mátyás J; Husz, Sándor; Kohánka, Valéria; Somos, Zsuzsa; Judák, Rita; Remenyik, E V A; Szegedi, Andrea; Nebenführer, László; Mészáros, Csilla; Horváth, Attila

    2002-06-01

    The authors followed the frequency of fragrance contact sensitization in Hungary in a multicentre study in the years 1998 and 1999. A total of 3,604 patients were tested with fragrance mix (FM), and positive reactions were observed in 294 (8.2%). In 160 FM hypersensitive patients, the study was continued with patch testing of the mix constituents (cinnamic alcohol, cinnamic aldehyde, eugenol, amyl cinnamic aldehyde, hydroxycitronellal, geraniol, isoeugenol, oak moss absolute). Of the patients tested, 70.6% produced positive reactions to the constituents. FM contact sensitization was mainly observed in female patients (74.4%). The incidence of contact urticaria in FM hypersensitive patients was 6.1%. Simultaneous patch test trials of other environmental contact allergens, in both early and late evaluations, mainly confirmed hypersensitivity reactions to balsams. Female dominance of hypersensitivity reactions observed during testing the individual components of the mix was striking (82.4%). In positive skin reactions, cinnamic alcohol, isoeugenol and oak moss provoked skin symptoms most frequently. We also tested the 104 patients who produced negative reactions to FM with the constituent individual allergens, with 11.9% positive incidence. The clinical symptoms of the patients were above all manifest in the form of contact eczema, located on the hands, face, eyelids and axillae. With this study, the authors, members of the Hungarian Contact Dermatitis Research Group, call attention to one of the most frequent allergens in the environment.

  8. Semisupervised learning using denoising autoencoders for brain lesion detection and segmentation.

    PubMed

    Alex, Varghese; Vaidhya, Kiran; Thirunavukkarasu, Subramaniam; Kesavadas, Chandrasekharan; Krishnamurthi, Ganapathy

    2017-10-01

    The work explores the use of denoising autoencoders (DAEs) for brain lesion detection, segmentation, and false-positive reduction. Stacked denoising autoencoders (SDAEs) were pretrained using a large number of unlabeled patient volumes and fine-tuned with patches drawn from a limited number of patients ([Formula: see text], 40, 65). The results show negligible loss in performance even when SDAE was fine-tuned using 20 labeled patients. Low grade glioma (LGG) segmentation was achieved using a transfer learning approach in which a network pretrained with high grade glioma data was fine-tuned using LGG image patches. The networks were also shown to generalize well and provide good segmentation on unseen BraTS 2013 and BraTS 2015 test data. The manuscript also includes the use of a single layer DAE, referred to as novelty detector (ND). ND was trained to accurately reconstruct nonlesion patches. The reconstruction error maps of test data were used to localize lesions. The error maps were shown to assign unique error distributions to various constituents of the glioma, enabling localization. The ND learns the nonlesion brain accurately as it was also shown to provide good segmentation performance on ischemic brain lesions in images from a different database.

  9. Laparoscopic repair of perforated peptic ulcer: patch versus simple closure.

    PubMed

    Abd Ellatif, M E; Salama, A F; Elezaby, A F; El-Kaffas, H F; Hassan, A; Magdy, A; Abdallah, E; El-Morsy, G

    2013-01-01

    Laparoscopic correction of perforated peptic ulcer (PPU) has become an accepted way of management. Patch omentoplasty stayed for decades the main method of repair. The goal of the present study was to evaluate whether laparoscopic simple repair of PPU is as safe as patch omentoplasty. Since June 2005, 179 consecutive patients of PPU were treated by laparoscopic repair at our centers. We conducted a retrospective chart review in December 2012. Group I (patch group) included patients who were treated with standard patch omentoplasty. Group II (non-patch group) included patients who received simple repair without patch. From June 2007 to Dec. 2012, 179 consecutive patients of PPU who were treated by laparoscopic repair at our centers were enrolled in this multi-center retrospective study. 108 patients belong to patch group. While 71 patients were treated with laparoscopic simple repair. Operative time was significantly shorter in group II (non patch) (p = 0.01). No patient was converted to laparotomy. There was no difference in age, gender, ASA score, surgical risk (Boey's) score, and incidence of co-morbidities. Both groups were comparable in terms of hospital stay, time to resume oral intake, postoperative complications and surgical outcomes. Laparoscopic simple repair of PPU is a safe procedure compared with the traditional patch omentoplasty in presence of certain selection criteria. Copyright © 2013 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  10. Distal vein patch as a form of autologus modification for infragenicular prosthetic bypass.

    PubMed

    Totic, Dragan; Rustempasic, Nedzad; Djedovic, Muhamed; Solakovic, Sid; Vukas, Haris; Aslani, Ilijas; Krvavac, Alma; Rudalija, Dzejra; Ahmetasevic, Alen

    2013-01-01

    Preferred graft for infragenicular bypass is autologus vein. The problem is when there is not available autologus vein. Literature suggest that in these situations, prosthetic graft with some form of modification of distal anastomosis with autogenic tissue is valuable adjunctive. Frequently used modifications are Miller's cuff, Taylor's patch and St. Mary's boot. Recently, there are reports on "Distal vein patch" as a form of autologus modification which, due to its simplicity and patency rate, attracted attention. The aim of this study was to evaluate benefits of this novel modification by comparing its patencies with other autologus modification of distal anastomosis. Study was performed on 60 patients, diabetics, with critical limb ischemia (CLI). Patients were divided in two groups: Group with distal vein patch modification; and group with some other form modification - control group. Patients were followed at least 22 months. We examined patency of grafts by physical examination or using Color Doppler. For statistical purposes we used KIaplan Meier analysis and curve. Significance was determined by Mann-Whitney, Fisher's exact, Pearsons chi square or Student T test as appropriate. P value less than 0,05 was considered significant. Groups were fairly matched relative to demographics, risk factors, operative intervention and distal anastomosis site. There was not statistical difference in two year primary patency between distal vein patch and control group--50% vs 53% respectivly (X2 = 0,08; p = 0,773). Also, there was not statistically significant difference in extremity survival (77% vs 77%) and patient survival between groups (89% vs 93%; X2 = 2,458; p = 0,117). This study proved equivalent patencies of infragenicular prosthetic bypasses performed using distal vein patch technique as with any other modification of distal anastomosis.

  11. Evaluation of a water-soluble bioadhesive patch for photodynamic therapy of vulval lesions.

    PubMed

    McCarron, Paul A; Donnelly, Ryan F; Zawislak, Agnieszka; Woolfson, A David; Price, John H; McClelland, Raymond

    2005-04-11

    An innovative bioadhesive patch intended primarily as a vulval drug delivery system and, specifically, as a means to deliver photosensitisers, or their prodrugs, for photodynamic purposes is described. The patch was formulated with a copolymer of methyl vinyl ether and maleic anhydride (PMVE/MA) as a bioadhesive matrix and poly(vinyl chloride) as a drug-impervious backing layer. Adhesive strength to neonate porcine skin, as a model substrate, was evaluated using peel and tensile testing measurements. Acceptabilities of non-drug loaded patches were appraised using human volunteers and visual-analogue scoring devices. An optimal formulation, with water uptake and peel strengths appropriate for vulval drug delivery, was cast from a 20% (w/w) PMVE/MA solution and adhered with a strength of approximately 1.7 Ncm(-2). Patient evaluation demonstrated comfort and firm attachment for up to 4h in mobile patients. Aminolevulinic acid, a commonly used photosensitiser, was formulated into the candidate formulation and applied to vulval intraepithelial neoplastic lesions. Fluorescence under ultraviolet illumination revealed protoporphyrin synthesis. The patch achieves the extended application times obligatory in topical photodynamic therapy of vulval lesions, thereby contributing to potential methods for the eradication of neoplastic lesions in the lower female reproductive tract.

  12. Measuring wearing times of glasses and ocular patches using a thermosensor device from orthodontics.

    PubMed

    Januschowski, Kai; Bechtold, Till E; Schott, Timm C; Huelber-Januschowski, Maren S; Blumenstock, Gunnar; Bartz-Schmidt, Karl-Ulrich; Besch, Dorothea; Schramm, Charlotte

    2013-12-01

    Amblyopia is one of the most common visual disorders in children. The risk of severe visual impairment on the healthy eye is doubled in patients with amblyopia. If detected early enough, the chances of visual rehabilitation are good. Treatment consists of refractive correction and occlusion of the dominant eye. Patient compliance is an important factor and can be monitored using thermosensors. It was the goal of our study to give proof of the principle that the wearing times of glasses and patches can be measured using a comparatively small and commercially available microsensor. Agreement between wearing times protocols of ocular patching/refractive correction and temperature measurements of thermosensors attached to the patches or glasses of three individuals were analysed using the Bland-Altman method. It was also analysed whether blinded persons could distinguish between temperature curves of patches and glasses, or temperature curves of an incubator or while worn in a pocket. The temperatures picked up by the microsensors indicate the beginning and the end wearing times of either glasses or ocular patches through steep temperature difference and a distinct temperature curve during measurements. Although blinded test persons were able to cleary distinguish between temperature profiles from incubator/pocket measurements compared to glasses/patching, glasses and patching curves could be discriminated correctly in only 50%. Differences between wearing time protocols and temperature measurements were within the limits of agreement as stated by the Bland-Altman plots. The TheraMon(®) microsensor can reliably measure wearing times of glasses and ocular patches without making the wearer uncomfortable, although the data are not unquestionable, especially in higher surrounding temperatures. Further studies on a larger number of individuals with different wearing profiles are needed. © 2013 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  13. Lettuce contact allergy.

    PubMed

    Paulsen, Evy; Andersen, Klaus E

    2016-02-01

    Lettuce (Lactuca sativa L.) and its varieties are important vegetable crops worldwide. They are also well-known, rarely reported, causes of contact allergy. As lettuce allergens and extracts are not commercially available, the allergy may be underdiagnosed. The aims of this article are to present new data on lettuce contact allergy and review the literature. Lettuce is weakly allergenic, and occupational cases are mainly reported. Using aimed patch testing in Compositae-allergic patients, two recent Danish studies showed prevalence rates of positive lettuce reactions of 11% and 22%. The majority of cases are non-occupational, and may partly be caused by cross-reactivity. The sesquiterpene lactone mix seems to be a poor screening agent for lettuce contact allergy, as the prevalence of positive reactions is significantly higher in non-occupationally sensitized patients. Because of the easy degradability of lettuce allergens, it is recommended to patch test with freshly cut lettuce stem and supplement this with Compositae mix. As contact urticaria and protein contact dermatitis may present as dermatitis, it is important to perform prick-to-prick tests, and possibly scratch patch tests as well. Any person who is occupationally exposed to lettuce for longer periods, especially atopics, amateur gardeners, and persons keeping lettuce-eating pets, is potentially at risk of developing lettuce contact allergy. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Nummular eczema: An addition of senile xerosis and unique cutaneous reactivities to environmental aeroallergens.

    PubMed

    Aoyama, H; Tanaka, M; Hara, M; Tabata, N; Tagami, H

    1999-01-01

    The pathogenesis of nummular eczema (NE) is still unknown. It often develops on the lower legs of elderly individuals with xerotic changes during the winter months. Such winter exacerbation is also observed in atopic dermatitis, in which there is a high incidence of cutaneous immune reactivities against environmental aeroallergens. Because of the total lack of information about skin reactivities in NE patients, we performed immunological as well as functional studies in their uninvolved skin. Prick tests and chamber scarification patch tests for representative aeroallergens were conducted on the flexor surface of the forearm in 26 NE patients, in 21 age-matched elderly persons without NE and in 43 healthy young controls. We found that the elderly subjects, regardless of their background, showed a significantly higher immediate skin reactivity to Candida albicans than the young controls. In contrast, patch testing revealed that, unlike the age-matched elderly subjects who showed a decrease in incidence of positive patch test reactions, the NE patients retained delayed contact sensitivity at a level comparable to that of the young healthy controls. They showed a significantly higher percentage of positive patch test reactions to Dermatophagoides farinae allergen (46%) and house dust allergen (35%) than the age-matched controls. Moreover, they also showed a significantly higher percentage of delayed hypersensitive reactions to C. albicans allergen (85%) than the age-matched controls (48%). Noninvasive functional assessment of the stratum corneum (SC) in unaffected skin areas of the lower legs in 8 NE patients demonstrated that, though the water barrier function of the SC was comparable to that of the age-matched controls, they showed a significantly lower hydration state of the SC than the age-matched controls. The xerotic skin of elderly individuals facilitates the development of cracking and fissuring of the skin surface in dry and cold winter. Such damage in the SC is sometimes aggravated by inadvertent scratching due to pruritus, allowing skin permeation of various environmental allergens. They may induce eczematous changes in those with preserved adequate delayed hypersensitivity despite their advanced age.

  15. Evaluation of canine adverse food reactions by patch testing with single proteins, single carbohydrates and commercial foods.

    PubMed

    Johansen, Cornelia; Mariani, Claire; Mueller, Ralf S

    2017-10-01

    Adverse food reaction (AFR) is an important differential diagnosis for the pruritic dog. It is usually diagnosed by feeding an elimination diet with a novel protein and carbohydrate source for eight weeks followed by subsequent food provocation. A previous study demonstrated that patch testing dogs with foods had a high sensitivity and negative predictability for selection of elimination diet ingredients. The aim of this study was to investigate patch testing with proteins, carbohydrates and dry commercial dog food in dogs to determine whether there was value in patch testing to aid the diagnosis of canine adverse food reaction. Twenty five privately owned dogs, with confirmed AFR, underwent provocation trials with selected food antigens and patch testing. For proteins, carbohydrates and dry dog food the sensitivity of patch testing was 100%, 70% and 22.2%, respectively; the negative predictive values of patch testing were 100%, 79% and 72%. The positive predictive values of patch testing for proteins and carbohydrates were 75% and 74%, respectively. This study confirmed that patch testing may be useful for the selection of a suitable protein source for an elimination diet in dogs with suspected AFR, but not as a diagnostic tool for canine AFR. Results for proteins are more reliable than for carbohydrates and the majority of positive patch test reactions were observed with raw protein. Patch testing with commercial dog food does not seem to be useful. © 2017 ESVD and ACVD.

  16. Tolerability of the capsaicin 8% patch following pretreatment with lidocaine or tramadol in patients with peripheral neuropathic pain: a multicentre, randomized, assessor-blinded study.

    PubMed

    Jensen, T S; Høye, K; Fricová, J; Vanelderen, P; Ernault, E; Siciliano, T; Marques, S

    2014-10-01

    Application of the capsaicin 8% patch is associated with treatment-related discomfort. Consequently, pretreatment for 60 min with anaesthetic cream is recommended; however, this may be uncomfortable and time consuming. We conducted a multicentre, randomized (1:1), assessor-blinded study in patients with peripheral neuropathic pain to assess tolerability of the capsaicin patch following topical lidocaine (4%) or oral tramadol (50 mg) pretreatment. The primary endpoint was the proportion of patients tolerating capsaicin patch application (ability to receive ≥90% of a 60-min application). Numeric Pain Rating Scale (NPRS) scores were assessed before, during and after treatment. Overall, 122 patients were included (61 per arm). The capsaicin patch was tolerated by 121 patients. Tolerability of the capsaicin patch was similar following pretreatment with lidocaine and tramadol. Following patch application, pain levels increased up to 55 min (change from baseline of 1.3 for lidocaine and 1.4 for tramadol). After patch removal, tramadol-treated patients experienced greater pain relief up to the end of day 1; in the evening, mean changes in NPRS scores from baseline were 0 for lidocaine and -1 for tramadol. Proportions of patients reporting increases of ≥2 NPRS points or >33% from baseline at one or more time point(s) on the day of treatment were similar between arms. Adverse event incidence was comparable between arms. Capsaicin 8% patch tolerability was similar in the two arms, with comparable results for most secondary endpoints. Tramadol given 30 min before patch application should be considered as an alternative pretreatment option in patients receiving capsaicin patch treatment. © 2014 The Authors. European Journal of Pain published by John Wiley & Sons Ltd on behalf of European Pain Federation - EFIC®.

  17. Recommendation to include fragrance mix 2 and hydroxyisohexyl 3-cyclohexene carboxaldehyde (Lyral) in the European baseline patch test series.

    PubMed

    Bruze, Magnus; Andersen, Klaus Ejner; Goossens, An

    2008-03-01

    The currently used fragrance mix in the European baseline patch test series (baseline series) fails to detect a substantial number of clinically relevant fragrance allergies. To investigate whether it is justified to include hydroxyisohexyl 3-cyclohexene carboxaldehyde (Lyral) and fragrance mix 2 containing hydroxyisohexyl 3-cyclohexene carboxaldehyde, citral, farnesol, coumarin, citronellol, and alpha-hexyl cinnamal in the European baseline patch test series. Survey of the literature on reported frequencies of contact allergy and allergic contact dermatitis from fragrance mix 2 and hydroxyisohexyl 3-cyclohexene carboxaldehyde (Lyral) as well as reported results of experimental provocation test. Fragrance mix 2 has been demonstrated to be a useful additional marker of fragrance allergy with contact allergy rates up to 5% when included in various national baseline patch test series. Of the fragrance substances present in fragrance mix 2, hydroxyisohexyl 3-cyclohexene carboxaldehyde is the most common sensitizer. Contact allergy rates between 1.5% and 3% have been reported for hydroxyisohexyl 3-cyclohexene carboxaldehyde in petrolatum (pet.) at 5% from various European centres when tested in consecutive dermatitis patients. From 2008, pet. preparations of fragrance mix 2 at 14% w/w (5.6 mg/cm(2)) and hydroxyisohexyl 3-cyclohexene carboxaldehyde at 5% w/w (2.0 mg/cm(2)) are recommended for inclusion in the baseline series. With the Finn Chamber technique, a dose of 20 mg pet. preparation is recommended. Whenever there is a positive reaction to fragrance mix 2, additional patch testing with the 6 ingredients, 5 if there are simultaneous positive reactions to hydroxyisohexyl 3-cyclohexene carboxaldehyde and fragrance mix 2, is recommended.

  18. Two sensitizing oxidation products of p-phenylenediamine patch tested in patients allergic to p-phenylenediamine.

    PubMed

    Young, Ewa; Zimerson, Erik; Bruze, Magnus; Svedman, Cecilia

    2016-02-01

    The results from a previous study indicated the presence of several possible sensitizers formed during oxidation of the potent sensitizer p-phenylenediamine (PPD) to which PPD-sensitized patients might react, in various patterns. To extract and analyse a yellow spot from a thin-layer chromatogram with oxidized PPD, to which 6 of 14 (43%) PPD-positive patients had reacted in a previous study, in order to identify potential sensitizer(s) and to patch test this/these substance(s) in the 14 PPD-positive patients. The yellow spot was extracted from a thin-layer chromatogram of oxidized PPD, and two substances, suspected to be allergens, were identified by analysis with gas chromatography mass spectrometry (GCMS). The 14 PPD-positive patients, who had been previously tested with the thin-layer chromatogram of oxidized PPD, participated in the investigation, and were tested with dilutions of the two substances. GCMS analysis identified 4-nitroaniline and 4,4'-azodianiline in the yellow spot. Of the 14 PPD-positive test patients, 5 (36%) reacted to 4-nitroaniline and 9 (64%) reacted to 4,4'-azodianiline. The results show that 4-nitroaniline and 4,4'-azodianiline, formed during oxidation of PPD, are potent sensitizers. PPD-sensitized patients react to a high extent to concentrations equimolar to PPD of 4-nitroaniline and 4,4'-azodianiline. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Delayed-type hypersensitivity to fragrance materials in a select North American population.

    PubMed

    Belsito, Donald V; Fowler, Joseph F; Sasseville, Denis; Marks, James G; De Leo, Vincent A; Storrs, Frances J

    2006-03-01

    In published reports from Europe, 3- and 4-(4-hydroxy-4-methylpentyl)cyclohexene-1-carboxaldehyde (HMPCC) (Lyral) has been described as a common cause of allergic contact dermatitis (ACD). In Europe, the rates of reaction to HMPCC among patients undergoing patch testing for suspected ACD have varied from 1.2 to 17.0%, depending on the country. Data on the incidence of sensitivity to HMPCC among North Americans with suspected ACD have not been reported. The goals of this study were (1) to assess the incidence of delayed-type hypersensitivity reactions to HMPCC among patients undergoing patch testing for evaluation of eczematous dermatitis at six centers throughout North America; (2) to determine the most appropriate concentration of HMPCC to use in performing patch tests; and (3) to compare and contrast the incidence rates for HMPCC hypersensitivity to those for other fragrance materials screened with the North American Contact Dermatitis Group (NACDG) screening tray, which includes fragrance mix, Myroxilon pereirae (balsam of Peru), cinnamic aldehyde, ylang ylang oil, jasmine absolute, and tea tree oil. This report represents the prospective multicenter data on patients tested with the fragrance-related allergens on the NACDG standard screening tray and with HMPCC at 5%, 1.5%, and 0.5% concentrations in petrolatum. Statistical analyses were performed with Student's t-test (two tailed) and the chi-square test. Data from 1,603 patients evaluated at five US sites and one Canadian site were analyzed. Most patients (87.8%) were Caucasian. The majority (67%) were women, and 26.2% had a history consistent with atopic dermatitis. The patients ranged in age from 1 to 88 years, and the mean +/- standard deviation was 46.3 +/- 16.5 years. Myroxilon pereirae (balsam of Peru) and fragrance mix were the most frequent patch-test-positive fragrance allergens (6.6% and 5.9%, respectively). Cinnamic aldehyde (1.7%), ylang ylang oil (0.6%), jasmine absolute (0.4%), HMPCC (0.4% for 5% HMPCC, 0.3% for 1.5% HMPCC, and 0.2% for 0.5% HMPCC), and tea tree oil (0.3%) less frequently yielded positive reactions. Men were more likely than women to be allergic to cinnamic aldehyde. Women were more likely than men to be allergic to jasmine absolute. Atopic patients were no more likely to react to fragrance materials than were nonatopic patients. Patients who reacted to jasmine absolute tended to be older than the general population whereas those who reacted to tea tree oil tended to be younger than the general population. There were no other demographic differences between patients who reacted to a given fragrance material and the entire population studied. Testing with fragrance mix and balsam of Peru failed to identify the majority of patients in this study who were found to be sensitized to jasmine absolute, HMPCC, or tea tree oil. HMPCC is an uncommon allergen in the North American population. We recommend testing with 5% HMPCC in petrolatum for those patients suspected of having a fragrance allergy.

  20. Evaluation of a tissue-engineered bovine pericardial patch in paediatric patients with congenital cardiac anomalies: initial experience with the ADAPT-treated CardioCel(R) patch.

    PubMed

    Neethling, William M L; Strange, Geoff; Firth, Laura; Smit, Francis E

    2013-10-01

    This study evaluated the safety, efficacy and clinical performance of the tissue-engineered ADAPT® bovine pericardial patch (ABPP) in paediatric patients with a range of congenital cardiac anomalies. In this single-centre, prospective, non-randomized clinical study, paediatric patients underwent surgery for insertion of the ABPP. Primary efficacy measures included early (<30 day) morbidity; incidence of device-related complications; haemodynamic performance derived from echocardiography assessment at 6- and 12-month follow-up and magnetic resonance imaging findings in 10 randomly selected patients at 12 months. Secondary measures included device-handling characteristics; shape and sizing characteristics and perioperative implant complications. The Aristotle complexity scoring system was used to score the complexity level of all surgical procedures. Patients completing the 12-month study were eligible to enter a long-term evaluation study. Between April 2008 and September 2009, the ABPP was used in 30 paediatric patients. In the 30-day postoperative period, no graft-related morbidity was observed. In total, there were 5 deaths (2 in the 30-day postoperative period and 3 within the first 6 postoperative months). All deaths were deemed due to comorbid non-graft-related events. Echocardiography assessment at 6 and 12 months revealed intact anatomical and haemodynamically stable repairs without any visible calcification of the patch. Magnetic resonance imaging assessment in 10 patients at 12 months revealed no signs of calcification. Fisher's exact test demonstrated that patients undergoing more complex, higher risk surgical repairs (Aristotle complexity score >8) were significantly more likely to die (P = 0.0055, 58% survival compared with 100% survival for less complex surgical repairs). In 19 patients, echocardiographic data were available at 18-36 months with no evidence of device calcification, infection, thromboembolic events or device failure. This study demonstrates the safety and efficacy of this engineered bovine pericardial patch as a cardiovascular substitute for surgical repair of both simple and more complex congenital cardiac defects.

  1. The analgesic effect of benzocaine mucoadhesive patches on orthodontic pain caused by elastomeric separators, a preliminary study.

    PubMed

    Eslamian, Ladan; Borzabadi-Farahani, Ali; Edini, Hosniye Zia; Badiee, Mohammad R; Lynch, Edward; Mortazavi, Alireza

    2013-09-01

    To study the effect of benzocaine mucoadhesive patches (20%) on orthodontic pain caused by elastomeric separators. A split-mouth design was used in 30 patients (12 female, 18 male, aged 23 ± 3.75 years). They were instructed to apply benzocaine and placebo patches randomly for right or left first permanent molars of maxillary/mandibular arches for 20 min and repeat this procedure every 6 h with a similar type patch. A 10 cm Visual Analogue Scale (VAS) was used for pain perception assessment in patients who were given benzocaine (benzocaine group) or placebo (placebo group) patches. Pain perception (VAS) was recorded immediately after separator placement and after 2, 6, 12, 18, 24, 48 and 72 h. The mean VAS (SD) for the placebo and benzocaine groups were 2.28 (1.08) and 1.63 (0.67), respectively. The pain peaked at 24 h. Significant pain perception differences were observed between groups at 2, 18, 24, 48 and 72 h. Pain perception was not different between genders or jaws investigated (p > 0.05). The Friedman test revealed significant differences in pain perception among various time intervals for benzocaine (χ (2) = 99.84, p = 0.000) and placebo (χ (2) = 102.361, p = 0.000) groups. Significant negative correlations (ρ) were found only between pain perception scores and patient's ages in the placebo group at 18 (-0.438), 24 (-0.526), 48 (-0.565) and 72 h (-0.458). The recorded mean VAS values were relatively low; however, the benzocaine 20% patches significantly reduced the post-separation orthodontic pain.

  2. Stratum corneum profiles of inflammatory mediators in patch test reactions to common contact allergens and sodium lauryl sulfate.

    PubMed

    Koppes, S A; Ljubojevic Hadzavdic, S; Jakasa, I; Franceschi, N; Jurakić Tončić, R; Marinović, B; Brans, R; Gibbs, S; Frings-Dresen, M H W; Rustemeyer, T; Kezic, S

    2017-06-01

    Recent studies have demonstrated allergen-specific differences in the gene expression of inflammatory mediators in patch tested skin. To determine levels of various inflammatory mediators in the stratum corneum (SC) after patch testing with common contact allergens and the skin irritant sodium lauryl sulfate (SLS). In total, 27 individuals who had previously patch tested positive to nickel, chromium, methylchloroisothiazolinone/methylisothiazolinone (MCI/MI) or para-phenylenediamine were retested and then patch tested with SLS and petrolatum, with petrolatum serving as the patch test control. At 72 h, the test sites were clinically graded and the SC samples collected on adhesive tape. The levels of 18 of the 32 quantified mediators differed significantly from that of the control patches for at least one of the tested substances. SLS and MCI/MI induced the largest number of immunomediators. Interleukin (IL)-16 levels were significantly higher in patch test reactions in all allergens than they were in the controls, while no significant difference was detected for SLS. Furthermore, a strong negative correlation was found between strength of patch test reaction and IL-1α levels. Cytokine profiles in the SC of patch tested skin did not show a distinct allergen-specific pattern. However, MCI/MI induced a larger and wider immune response than the other allergens, perhaps due to its potency as an irritant. The levels of IL-16 were significantly increased in patch test reactions to allergens but not to SLS; thus, they may help clinicians to differentiate between allergic contact dermatitis and irritant contact dermatitis. © 2016 British Association of Dermatologists.

  3. Stability of fragrance patch test preparations applied in test chambers.

    PubMed

    Mowitz, M; Zimerson, E; Svedman, C; Bruze, M

    2012-10-01

    Petrolatum patch test preparations are for practical reasons often applied in test chambers in advance, several hours or even days before the patient is tested. As many fragrance compounds are volatile it may be suspected that petrolatum preparations applied in test chambers are not stable over time. To investigate the stability of petrolatum preparations of the seven chemically defined components in the fragrance mix (FM I) when stored in test chambers. Samples of petrolatum preparations applied in test chambers stored at room temperature and in a refrigerator for between 4 and 144 h were analysed using liquid chromatographic methods. The concentration decreased by ≥ 20% within 8 h in four of seven preparations stored in Finn chambers at room temperature. When stored in a refrigerator only the preparation of cinnamal had decreased by ≥ 20% within 24 h. The stability of preparations of cinnamal stored in IQ chambers with a plastic cover was slightly better, but like the preparations applied in Finn chambers, the concentration decreased by ≥ 20% within 4 h at room temperature and within 24 h in a refrigerator. Cinnamal and cinnamyl alcohol were found to be more stable when analysed as ingredients in FM I compared with when analysed in individual preparations. Within a couple of hours several fragrance allergens evaporate from test chambers to an extent that may affect the outcome of the patch test. Application to the test chambers should be performed as close to the patch test occasion as possible and storage in a refrigerator is recommended. © 2012 The Authors. BJD © 2012 British Association of Dermatologists.

  4. Safety of fentanyl initiation according to past opioid exposure among patients newly prescribed fentanyl patches

    PubMed Central

    Friesen, Kevin J.; Woelk, Cornelius; Bugden, Shawn

    2016-01-01

    Background: Although a convenient opioid delivery system, transdermal fentanyl patches have caused several deaths and resulted in safety warnings reminding prescribers that fentanyl patches should be prescribed only for patients who have adequate prior exposure to opioids. We conducted a longitudinal analysis of the safety of fentanyl initiation by examining past opioid exposure among patients newly prescribed fentanyl patches. Methods: We identified all patients in the province of Manitoba who were newly prescribed fentanyl patches between Apr. 1, 2001, and Mar. 31, 2013. We converted all prior opioid use to oral morphine equivalents and determined the average daily dose in the 7–30 days before initial fentanyl patch use. Fentanyl initiation was considered unsafe if the patient’s pre-fentanyl opioid exposure was below the recommended level. Results: We identified 11 063 patients who began using fentanyl patches during the study period. Overall, fentanyl initiation was deemed unsafe in 74.1% of cases because the patient’s prior opioid exposure was inadequate. Women and patients 65 years of age and older were more likely than men and younger patients, respectively, to have inadequate prior opioid exposure (p < 0.001 for each comparison). The proportion of patients who had unsafe prescriptions for fentanyl patches decreased significantly over the study period, from 87.0% in 2001 to 50.0% in 2012 (p < 0.001). Interpretation: The safety of fentanyl initiation improved over the study period, but still half of fentanyl patch prescriptions were written for patients with inadequate prior opioid exposure. Review of prior opioid exposure may be a simple but important way to improve the safe use of fentanyl patches. PMID:27044480

  5. Lessons from atopy patch testing in atopic dermatitis.

    PubMed

    Kerschenlohr, Karin; Darsow, Ulf; Burgdorf, Walter H C; Ring, Johannes; Wollenberg, Andreas

    2004-07-01

    The exposure of atopic eczema (AE) patients to their relevant protein allergens (eg, from house dust mite, cat dander, grass pollen, or food allergens) can trigger an exacerbation or maintain the disease. Diagnostic procedures are needed to specify allergen avoidance recommendations for the individual patient. Skin prick tests and specific serum IgE tests might be helpful in pointing out potential trigger factors, but relevance needs to be confirmed (eg, with food provocation tests). The atopy patch test (APT) involves the epicutaneous application of intact protein allergens in a diagnostic patch test setting with an evaluation of the induced eczematous skin lesions after 24 to 72 hours. The APT targets the cellular component of AE and helps round out the AE test spectrum. As a number of apparently minor test modifications greatly influence the sensitivity, specificity, and reproducibility of the APT, the European Task Force on Atopic Dermatitis (ETFAD) has developed a standardized APT technique. It consists of purified allergen preparations in petrolatum, applied in 12-mm diameter Finn chambers mounted on Scanpor tape to non-irritated, non-abraded, or tape-stripped skin of the upper back. The APT is read at 48 and 72 hours according to the test criteria and reading key of the ETFAD for appearance of erythema, and number and distribution pattern of the papules. In contrast with skin prick tests, the APT might even detect a relevant sensitization in the absence of specific IgE. Many studies have been undertaken to objectify the sensitivity and specificity of the APT to show its diagnostic use in clinical practice.

  6. Multicenter Patch Testing With a Resol Resin Based on Phenol and Formaldehyde Within the International Contact Dermatitis Research Group.

    PubMed

    Isaksson, Marléne; Ale, Iris; Andersen, Klaus; Diepgen, Thomas; Elsner, Peter; Goossens, An; Goh, Chee-Leok; Jerajani, Hemangi; Maibach, Howard; Matsunaga, Kayoko; McFadden, John; Nixon, Rosemary; Sasseville, Denis; Bruze, Magnus

    2015-01-01

    Contact allergy to phenol-formaldehyde resins (PFRs) based on phenol and formaldehyde is not detected by a p-tertiary-butylphenol-formaldehyde resin included in most baseline patch test series. The aims of this study were to investigate the contact allergy rate to PFR-2 in an international population and to investigate associated simultaneous allergic reactions. Thirteen centers representing the International Contact Dermatitis Research Group included PFR-2 into their patch test baseline series during a period of 6 months in 2012. Of 2259 patients tested, 28 (1.2%) reacted to PFR-2. Of those 28 individuals, one had a positive reaction to formaldehyde and 2 to p-tertiary-butylphenol-formaldehyde resin. Simultaneous allergic reactions were noted to colophonium in 3, to Myroxylon pereirae in 5, and to fragrance mix I in 8. The contact allergy frequency in the tested population (1.2%) merits its inclusion into the international baseline series and possibly also into other baseline series after appropriate investigations. Significantly, overrepresented simultaneous allergic reactions were noted for M. pereirae and fragrance mix I.

  7. Multicentre patch testing with a resol resin based on phenol and formaldehyde.

    PubMed

    Isaksson, Marléne; Inerot, Annica; Lidén, Carola; Matura, Mihaly; Stenberg, Berndt; Möller, Halvor; Bruze, Magnus

    2011-07-01

    Contact allergy to phenol-formaldehyde resins (PFRs) based on phenol and formaldehyde is not detected by a p-tertiary-butylphenol-formaldehyde resin (PTBP-FR) included in most baseline patch test series. To investigate the rate of contact allergy to PFR-2 (a mixture of monomers and dimers from a resol resin based on phenol and formaldehyde) in a Swedish population, and to investigate associated simultaneous allergic reactions. Five centres representing the Swedish Contact Dermatitis Research Group included PFR-2 in their patch test baseline series for a period of 1.5 years. Of 2504 patients tested, 27 (1.1%) reacted to PFR-2. Of those 27 individuals, 2 had a positive reaction to formaldehyde and 2 to PTBP-FR. Simultaneous allergic reactions were noted to colophonium in 6, to Myroxylon pereirae in 14, and to fragrance mix I in 15. The contact allergy frequency in the tested population (1.1%) merits its inclusion in the Swedish baseline series and possibly also in other baseline series. Simultaneous allergic reactions were noted to colophonium, M. pereirae, and fragrance mix I. © 2011 John Wiley & Sons A/S.

  8. Patch testing with uranyl acetate in veterans exposed to depleted uranium during the 1991 Gulf war and the Iraqi conflict.

    PubMed

    Shvartsbeyn, Marianna; Tuchinda, Papapit; Gaitens, Joanna; Squibb, Katherine S; McDiarmid, Melissa A; Gaspari, Anthony A

    2011-01-01

    The Depleted Uranium Follow-Up Program is a clinical surveillance program run by the Baltimore Veterans Affairs Medical Center since 1993 for veterans of the Gulf and Iraqi wars who were exposed to depleted uranium (DU) as a result of "friendly-fire" incidents. In 2009, 40 veterans from this cohort were screened for skin reactivity to metals by patch-testing with extended metal series and uranyl acetate (0.25%, 2.5%, and 25%). A control arm comprised 46 patients without any known occupational exposures to DU who were seen at the University of Maryland Dermatology Clinic for evaluation of allergic contact dermatitis. Excluding irritant reactions, no patch-test reactions to uranyl acetate were observed in the participants. Irritant reactions to DU were more common in the clinic cohort, likely reflective of the demographic differences between the two arms of the study. Biologic monitoring of urine uranium concentrations in the DU program participants with 24-hour urine samples showed evidence of percutaneous uranium absorption from the skin patches. We conclude that dermatitis observed in a subset of the veterans was unrelated to their military DU exposure. Our data suggest that future studies of skin testing with uranyl acetate should utilize 0.25%, the least irritating concentration.

  9. Patch test results of the dental personnel with contact dermatitis.

    PubMed

    Kocak, Oguzhan; Gul, Ulker

    2014-12-01

    Dental personnel have high risk of occupational contact dermatitis. The aim of this study is to detect the materials which cause contact sensitization and the frequency of contact dermatitis by using patch tests with European standard series and dental screening series in dental personnel. Between August 2008 and July 2009, 461 dental personnel working in Ankara (Turkey) were examined and age, gender, previous history of dermatitis, area of the skin affected and clinical diagnosis were noted. About 198 (43%) of the dental personnel were diagnosed contact dermatitis. Sixty-five of the dental personnel accepted to be patch tested. Dental technicians, dentists and dental nurses constitute 69.2%, 24.6% and 6.2% of patch tested 65 patients, respectively. Positive reactions to at least one allergen were detected with European standard series at 20% and with dental series at 10.8% among the dental personnel. The most common allergens were nickel sulfate (12.3%), acrylates (6.1%) and para-tertiary-butylphenol-formaldehyde resin (4.6%). The most common acrylate was ethyleneglycol dimethacrylate (3.1%). We believe our study will be helpful to dermatologists about frequency of contact dermatitis among dental personnel and allergens that cause contact sensitivity for developing new methods to protect the personnel in dentistry against sensitization.

  10. The Role of Airborne Proteins in Atopic Dermatitis

    PubMed Central

    Hostetler, Sarah Grim; Kaffenberger, Benjamin; Hostetler, Todd

    2010-01-01

    Atopic dermatitis is a common, chronic skin condition. A subpopulation of patients may have cutaneous exposure to common airborne proteins exacerbating their disease through direct proteolytic activity, direct activation of proteinase-activated receptor-2 itch receptors, and immunoglobulin E binding. The most common airborne proteins significant in atopic dermatitis include house dust mites, cockroach, pet dander, and multiple pollens. The literature on atopy patch testing, skin-prick testing, and specific IgE is mixed, with greater support for the use of atopy patch test. Patients with airborne proteins contributing to their disease typically have lesions predominately on air-exposed skin surfaces including the face, neck, and arms; a history of exacerbations after exposure to airborne proteins; severe disease resistant to conventional therapies; and concurrent asthma. Treatment strategies include airborne protein avoidance, removal of airborne proteins from the skin, and barrier repair. Further research is needed to establish the benefit of allergen-specific immunotherapy. PMID:20725535

  11. The dose-response relationship between the patch test and ROAT and the potential use for regulatory purposes.

    PubMed

    Fischer, Louise Arup; Voelund, Aage; Andersen, Klaus Ejner; Menné, Torkil; Johansen, Jeanne Duus

    2009-10-01

    Allergic contact dermatitis is common and can be prevented. The relationship between thresholds for patch tests and the repeated open application test (ROAT) is unclear. It would be desirable if patch test and ROAT data from already sensitized individuals could be used in prevention. The aim was to develop an equation that could predict the response to an allergen in a ROAT based on the dose-response curve derived by patch testing. Results from two human experimental elicitation studies with non-volatile allergens, nickel and the preservative methyldibromo glutaronitrile (MDBGN), were analysed by logistic dose-response statistics. The relation for volatile compounds was investigated using the results from experiments with the fragrance chemicals hydroxyisohexyl 3-cyclohexene carboxaldehyde and isoeugenol. For non-volatile compounds, the outcome of a ROAT can be estimated from the patch test by: ED(xx)(ROAT) = 0.0296 ED(xx)(patch test). For volatile compounds, the equation predicts that the response in the ROAT is more severe than the patch test response, but it overestimates the response. This equation may be used for non-volatile compounds other than nickel and MDBGN, after further validation. The relationship between the patch test and the ROAT can be used for prevention, to set safe levels of allergen exposure based on patch test data.

  12. Drug skin tests in cutaneous adverse drug reactions to pristinamycin: 29 cases with a study of cross-reactions between synergistins.

    PubMed

    Barbaud, A; Trechot, P; Weber-Muller, F; Ulrich, G; Commun, N; Schmutz, J L

    2004-01-01

    The present study was made to determine the value of drug skin tests in patients with cutaneous adverse drug reactions (CADRs) due to a synergistin (pristinamycin) and to determine the frequency of cross-reactions between synergistins. 29 patients were referred during the onset of the CADR due to pristinamycin: 18 with maculopapular rash, 9 erythrodermas, 1 angioedema and 1 Stevens-Johnson syndrome. They all had patch tests with pristinamycin and, in most cases, with other synergistins [virginiamycin and dalfopristin-quinupristin (DQ)], prick tests (10 cases) and intradermal tests (IDT) (5 cases). Skin tests with synergistins were positive in 27 cases, patch tests with pristinamycin in 20/29 cases (69%), prick tests with pristinamycin in 3/9 cases on immediate (1 case) or on delayed (2 cases) readings, and IDT with DQ in 4/5 cases. Cross-reactions between synergistins occurred in 9/22 with virginiamycin and in 7/8 cases with DQ. Skin tests with synergistins are useful in investigating CADR due to pristinamycin. Synergistins are composed of 2 chains (1 depsipeptide and 1 macrocyclic lactone) with many structural analogies between all synergistins. According to the chemical structures and our results, it seems advisable to avoid all synergistins in patients with CADR due to pristinamycin.

  13. Epidemiological, clinical and allergological observations on pompholyx.

    PubMed

    Lodi, A; Betti, R; Chiarelli, G; Urbani, C E; Crosti, C

    1992-01-01

    We have studied a group of 104 patients with pompholyx, to investigate the relationship between allergological factors and its etiopathogenesis. The following examinations were performed: blood sampling (routine tests and IgE levels), allergological tests (patch, prick, intradermal, and oral provovation tests with nickel sulphate), skin biopsy to exclude pemphigus vulgaris or bullous pemphigoid. An accurate history of familial and personal allergic diathesis was enquired for and various possible aggravating factors (season, microclimate, perspiration and emotional stress) were considered. The results were age and sex-matched with a healthy control group (208 subjects). We found familial and personal atopic diathesis in 50% of patients versus 11.5% of controls (p less than 0.001); 39 patients (37.49%) also had high levels of IgE. Nickel sulphate was the allergen with the highest positivity on patch testing: 20.19% versus 6.25% of the control group (p less than 0.001). The % of patients allergic to nickel reached 26%, including those (6 patients) reacting to the oral provocation test. Season (43 patients) and hyperhidrosis (38) were the aggravating factors most commonly claimed. We detected no correlation between age, sex, grading of pompholyx and the allergological parameters investigated. Though several different allergological findings have previously been reported in dyshidrosis, their role in its pathogenesis has not yet been fully explained. We think that different haptens or antigens can produce the same clinical and histological picture of pompholyx in predisposed subjects.

  14. North American contact dermatitis group patch test results: 2011-2012.

    PubMed

    Warshaw, Erin M; Maibach, Howard I; Taylor, James S; Sasseville, Denis; DeKoven, Joel G; Zirwas, Matthew J; Fransway, Anthony F; Mathias, C G Toby; Zug, Kathryn A; DeLeo, Vincent A; Fowler, Joseph F; Marks, James G; Pratt, Melanie D; Storrs, Frances J; Belsito, Donald V

    2015-01-01

    Patch testing is an important diagnostic tool for assessment of allergic contact dermatitis (ACD). This study documents the North American Contact Dermatitis Group (NACDG) patch-testing results from January 1, 2011, to December 31, 2012. At 12 centers in North America, patients were tested in a standardized manner with a series of 70 allergens. Data were manually verified and entered into a central database. Descriptive frequencies were calculated, and trends analyzed using χ statistics. Four thousand two hundred thirty-eight patients were tested; of these, 2705 patients (63.8%) had at least 1 positive reaction, and 2029 (48.0%) were ultimately determined to have a primary diagnosis of ACD. Four hundred eight patients (9.6%) had occupationally related skin disease. There were 7532 positive allergic reactions. As compared with previous reporting periods (2009-2010 and 2000-2010), positive reaction rates statistically increased for 6 allergens: methylchloroisothiazolinone/methylisothiazolinone (5.0%; risk ratios [RRs]: 2.01 [1.60-2.52], 1.87 [1.61-2.18]), lanolin alcohol (4.6%; RRs 1.83 [1.45-2.30], 2.10 [1.79-2.47]), cinnamic aldehyde (3.9%; 1.69 [1.32-2.15], 1.53 [1.28-1.82]), glutaral (1.5%; 1.67 [1.13-2.48], 1.31 [1.00-1.71]), paraben mix (1.4%; 1.77 [1.16-2.69], 1.44 [1.09-1.92]), and fragrance mix I (12.1%; RRs 1.42 [1.25-1.61], 1.24 [1.14-1.36]). Compared with the previous decade, positivity rates for all formaldehyde-releasing preservatives significantly decreased (formaldehyde 6.6%; RR, 0.82 [0.73, 0.93]; quaternium-15 6.4% RR 0.75 [0.66, 0.85]; diazolidinyl urea 2.1%; RR, 0.67 [0.54, 0.84]; imidazolidinyl urea 1.6%, 0.60 [0.47, 0.77]; bronopol 1.6%; RR, 0.60 [0.46, 0.77]; DMDM hydantoin 1.6%; RR, 0.59 [0.54, 0.84]). Approximately a quarter of patients had at least 1 relevant allergic reaction to a non-NACDG allergen. In addition, approximately one-fourth to one-third of reactions detected by NACDG allergens would have been hypothetically missed by T.R.U.E. TEST (SmartPractice Denmark, Hillerød, Denmark). These data document the beginning of the epidemic of sensitivity to methylisothiazolinones in North America, which has been well documented in Europe. Patch testing with allergens beyond a standard screening tray is necessary for complete evaluation of occupational and nonoccupational ACD.

  15. Cannabis Use Surveillance by Sweat Analysis.

    PubMed

    Gambelunghe, Cristiana; Fucci, Nadia; Aroni, Kyriaki; Bacci, Mauro; Marcelli, Antonio; Rossi, Riccardo

    2016-10-01

    Sweat testing, an alternative matrix for establishing drug abuse, offers additional benefits to the more common biological samples. The authors developed a procedure using gas chromatography-mass spectrometry to test for Δ9-tetrahydrocannabinol, 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid, cannabinol (CBN), and cannabidiol (CBD) in a sweat patch. The results were compared with urine and hair sample results. Urine, hair, and sweat samples were simultaneously collected from 12 patients who were involved, respectively, in forensic case and monitoring abuse. Selectivity, linearity, limit of detection (LOD), limit of quantification (LOQ), recovery, intraday and interday imprecision, and inaccuracy of the quantification procedure were validated. LODs in hair were 0.05 ng/mg for Δ9-tetrahydrocannabinol, CBN, and CBD, and 0.005 ng/mg for 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid. The LOD for sweat was 0.30 ng/patch for all substances. The LOQ in hair was 0.1 ng/mg for Δ9-tetrahydrocannabinol, CBN, and CBD, and 0.01 ng/mg for 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid. The LOQ was 0.4 ng/patch in sweat for each analyte. Cannabinoid in urine was determined by means of immunochemical screening (cutoff 11-nor-Δ-tetrahydrocannabinol-9-carboxylic acid 50 ng/mL). All subjects tested positive for 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid and Δ9-tetrahydrocannabinol in urine and hair. In sweat samples, Δ9-tetrahydrocannabinol was found in all patches (0.4-2.0 ng/patch); 6 cases were positive for CBN (0.4-0.5 ng/patch) and 3 for CBD (0.4-0.6 ng/patch); 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid was never detected in patches. Present sweat analysis results integrated the information from hair and urine and showed that sweat analysis is a suitable, noninvasive method for monitoring compliance with rehabilitation therapy and for detecting recent cumulative use of cannabinoids.

  16. Occupational protein contact dermatitis from spices in a butcher: a new presentation of the mugwort-spice syndrome.

    PubMed

    Anliker, Mark David; Borelli, Siegfried; Wüthrich, Brunello

    2002-02-01

    Protein contact dermatitis to meat is well known in butchers; spices are another source of potential contact allergy and usually are not recognized. We present a first case of contact-dermatitis to spice mix in a 39-year-old-butcher. The patient underwent skin prick testing (SPT) with standard allergens (ALK) and different meat and spice extracts (Stallergènes), scratch-patch testing with spice mix containing glutamate, paprika and other spices. Specific serum-IgE was measured with CAP-FEIA. SPT only showed an immediate-type sensitization to mugwort (+ +), as well as different spices (paprika +, curry +, cumin +) and camomile (+ + +). Scratch-patch tests were negative for different meat, but strongly positive for spice mix (+ + +) after 30 min (wheal and flare) and (+ +) after 48 h (infiltration and vesiculation). Two healthy controls were tested negative for spice mix used from that patient (scratch-patch). Specific IgE was slightly elevated for paprika 0.47 kU/L (CAP class 1), anise 0.43 kU/L, curry 0.36 kU/L and mugwort 3.83 kU/L. Sx1 atopy-multiscreen was 3.8 kU/L due to a sensitization to mugwort alone. The tests performed demonstrate an IgE-mediated contact allergy to spices but also a delayed type allergy to spice mix as a manifestation of the mugwort-spice syndrome in this individual. When testing for occupational dermatitis in butchers, protein contact allergy to spices must also be taken into consideration.

  17. Variations in laser energy outputs over a series of simulated treatments.

    PubMed

    Lister, T S; Brewin, M P

    2014-10-01

    Test patches are routinely employed to determine the likely efficacy and the risk of adverse effects from cutaneous laser treatments. However, the degree to which these represent a full treatment has not been investigated in detail. This study aimed to determine the variability in pulse-to-pulse output energy from a representative selection of cutaneous laser systems in order to assess the value of laser test patches. The output energies of each pulse from seven cutaneous laser systems were measured using a pyroelectric measurement head over a 2-h period, employing a regime of 10-min simulated treatments followed by a 5-min rest period (between patients). Each laser system appeared to demonstrate a different pattern of variation in output energy per pulse over the period measured. The output energies from a range of cutaneous laser systems have been shown to vary considerably between a representative test patch and a full treatment, and over the course of an entire simulated clinic list. © 2014 British Association of Dermatologists.

  18. [Occupational contact dermatitis in metal workers and gender effect].

    PubMed

    Filon, F Larese; Marzioti, G; Fortina, A Belloni; Peserico, A; De Toni, A; Corradini, M T; Carrabba, E; Fiorito, A

    2007-01-01

    Contact dermatitis is more frequent among women for anatomical reasons and for extraprofessional exposure to irritants and detergents during homeworks. In addition sensitisation to contact haptens is different in sexes. The aim of our work was to evaluate the association between patch test skin sensitizations and professional exposure to metals analyzing data for gender. Of the 15.217 patients patch tested for dermatitis, 678 were metalworkers. The statistical analysis revealed a significant association between dermatitis and sensitisation to nickel in professional exposed women (OR = 1.68; LC50% 1.11-6.50) while metal sensitisation (Cr.Ni and Co) was not relevant in men: for them a significant association between dermatitis and sensitisation was found to quaternium (OR = 3.91; LC95% 1.18-12.9), to mercaptobenzothiazole (OR = 2.69; LC50% 1.11-6.50) and to ethylendiamine dichloride (OR = 2.53; LC95% 1-6.41). The authors stress the need to evaluate patch test sensitisation considering gender effects.

  19. Cognitive rehabilitation with right hemifield eye-patching for patients with sub-acute stroke and visuo-spatial neglect: a randomized controlled trial.

    PubMed

    Aparicio-López, Celeste; García-Molina, Alberto; García-Fernández, Juan; Lopez-Blazquez, Raquel; Enseñat-Cantallops, Antonia; Sánchez-Carrión, Rocío; Muriel, Vega; Tormos, Jose María; Roig-Rovira, Teresa

    2015-01-01

    To assess whether, following a right-hemisphere stroke, the combined administration of computer-based cognitive rehabilitation and right hemifield eye-patching in patients with visuo-spatial neglect is more effective than computer-based cognitive rehabilitation alone. Twelve patients were randomized into two treatment groups: a single treatment group (n = 7) and a combination treatment group (n = 5). In both cases, the treatment consisted of a mean number of 15 sessions, each lasting 1 hour. Visuo-spatial neglect was assessed using a specific exploration protocol (Bell Cancellation Test, Figure Copying of Odgen, Line Bisection, Baking Tray Task and Reading Task). The functional effects of the treatment were assessed using the Catherine Bergego Scale. Significant between-group differences were observed when comparing the pre- and post-treatment scores for the Reading Task. No differences were observed in either group in the Catherine Bergego Scale administered at baseline and at the final intervention. The results obtained do not allow one to conclude that the combination treatment with cognitive rehabilitation and right hemifield eye-patching is more effective than cognitive rehabilitation alone. Although partial improvement in the performance of neuropsychological tests was observed, this improvement is not present at functional level.

  20. Prospective Single-Center Observational Study of the Allergenic Potential of Mercromina Film and Other Common Antiseptics in Patients With Contact Dermatitis.

    PubMed

    Baltà Cruz, S; Moreno Ribera, N; Estrach Panella, M T

    Although Mercromina Film and other topical antiseptics are widely used, they are not included in the standard series recommended by the Spanish Contact Dermatitis and Skin Allergy Research Group for testing suspected allergic contact dermatitis (ACD). Furthermore, no recent studies have investigated the allergenic potential of merbromin. To determine the allergenic potential of merbromin and compare it with that of other topical antiseptics widely used in clinical practice, including povidone-iodine, chlorhexidine, and eosin. Prospective single-center observational safety study of 105 patients with suspected ACD seen at the dermatology department of our hospital. Of the 105 patients studied, 1.9% had a positive patch test to merbromin and 12.4% were sensitized to povidone-iodine. The differences in the proportion of patients with ACD to Betadine Solución Dérmica (povidone-iodine) compared with the rest of the antiseptics was statistically significant (McNemar test, P<.05). No adverse reactions were observed in any of the patients. Based on the patch tests conducted, Mercromina Film has very low allergenic potential. The highest allergenic potential was observed for povidone-iodine. Copyright © 2017 AEDV. Publicado por Elsevier España, S.L.U. All rights reserved.

  1. Hypersensitivity reactions to metal implants: laboratory options.

    PubMed

    Carossino, Anna Maria; Carulli, Christian; Ciuffi, Simone; Carossino, Roberto; Zappoli Thyrion, Giorgia Donata; Zonefrati, Roberto; Innocenti, Massimo; Brandi, Maria Luisa

    2016-11-23

    All implant compounds undergo an electrochemical process when in contact with biological fluids, as well as mechanical corrosion due to abrasive wear, with production of metal debris that may inhibit repair processes. None of the commonly-used methods can diagnose implant allergies when used singly, therefore a panel of tests should be performed on allergic patients as pre-operative screening, or when a postoperative metal sensitisation is suspected. We analysed patients with painful prostheses and subjects prone to allergies using the Patch Test in comparison with the Lymphocyte Transformation Test. Cytokine production was evaluated to identify prognostic markers for early diagnosis of aseptic loosening. Metal debris endocytosis and cytoskeletal rearrangement was visualised by confocal microscopy. Our results demonstrate that the Lymphocyte Transformation Test can identify patients who have a predisposition to develop allergic reactions and can confirm the diagnosis of hypersensitivity in patients with painful prostheses. The prevalence of a Th2-cytokine pattern may be used to identify predisposition to the development of allergic diseases, while the selective presence of osteoclastogenic cytokines may be used as predictor of a negative outcome in patients with painful prosthesis. The hypothesis of the prognostic value of these cytokines as early markers of aseptic loosening is attractive, but its confirmation would require extensive testing. The Lymphocyte Transformation Test is the most suitable method for testing systemic allergies. We suggest that the combined use of the Patch Test and the Lymphocyte Transformation Test, associated with cytokine detection in selected patients, could provide a useful tool for preventive evaluation of immune reactivity in patients undergoing primary joint replacement surgery, and for clinical monitoring of the possible onset of a metal sensitization in patients with implanted devices.

  2. [Post marketing surveillance study with an analgesic (transdermal buprenorphine patch) in patients with moderate to severe chronic pain].

    PubMed

    Tschirner, M; Ritzdorf, I; Brünjes, R

    2008-09-18

    To obtain information on the efficacy, tolerability and safetyofa transdermal buprenorphine patch (Transtec PRO) in patients with moderate to severe chronic pain. In addition it should be evaluated to what extent the two fixed patch change days per weekare simplifyingthe therapy. In this prospective multi-center post marketing surveillance study patients with chronic cancer and non-cancer pain were treated with transdermal buprenorphine for up to eight weeks. The evaluation included pain intensity, the dosage of the applied analgesics and additional therapies, the renal function (by serum creatinine) and adverse events. 3654 patients were treated for a mean of 50.4 days. Using the NRS-11 the mean pain intensity decreased from 6.3 at the time when patients were switched to the transdermal buprenorphine patch to 2.6 at the last treatment evaluation. The matrix patch was safe and well tolerated also in patients with advanced renal insufficiency. Adverse events were reported in 6.7% of the patients. 89.3% of the physicians quoted to prefer transdermal buprenorphine with the two fixed patch change days per week compared to the pre-treatment. The buprenorphine-containing matrix patch was effective and well tolerated in patients with moderate to severe chronic cancer and noncancer pain. From the physicians view the two fixed patch change days per week facilitate the guidance of therapy. In patients with advanced renal insufficiency a dose adjustment is not necessary.

  3. Contact allergy to epoxy hardeners.

    PubMed

    Aalto-Korte, Kristiina; Suuronen, Katri; Kuuliala, Outi; Henriks-Eckerman, Maj-Len; Jolanki, Riitta

    2014-09-01

    Diglycidylether of bisphenol A resin is the most important sensitizer in epoxy systems, but a minority of patients develop concomitant or solitary contact allergy to epoxy hardeners. At the Finnish Institute of Occupational Health, several in-house test substances of epoxy hardeners have been tested in a special epoxy compound patch test series. To analyse the frequency and clinical relevance of allergic reactions to different epoxy hardeners. Test files (January 1991 to March 2013) were screened for contact allergy to different epoxy hardeners, and the clinical records of patients with allergic reactions were analysed for occupation, concomitant allergic reactions, and exposure. The most commonly positive epoxy hardeners were m-xylylenediamine (n = 24), 2,4,6-tris-(dimethylaminomethyl)phenol (tris-DMP; n = 14), isophorone-diamine (n = 12), and diethylenetriamine (n = 9). Trimethylhexamethylenediamine (n = 7), tetraethylenepentamine (n = 4), and triethylenetetramine (n = 2) elicited some reactions, although most patients were found to have no specific exposure. Allergic reactions to hexamethylenetetramine, dimethylaminopropylamine and ethylenediamine dihydrochloride were not related to epoxy products. Tris-DMP is an important sensitizer in epoxy hardeners, and should be included in the patch test series of epoxy chemicals. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Is there a risk of active sensitization to PPD by patch testing the general population?

    PubMed

    Thyssen, Jacob Pontoppidan; Menné, Torkil; Nielsen, Niels Henrik; Linneberg, Allan

    2007-08-01

    Para-phenylenediamine (PPD), a constituent of permanent hair dyes, may cause contact allergy in exposed individuals. It has previously been questioned whether a patch testing with PPD in population-based epidemiological studies is entirely safe. The Glostrup allergy studies patch tested the same cohort twice. In 1990, 567 persons were patch-tested and only one person had a (+) positive reaction to PPD. In 1998, 540 persons were re-invited to a new patch test and 365 (participation rate 68%) were re-tested. There were no positive reactions to PPD. These studies indicate that patch testing with PPD in individuals with no previous positive reactions to PPD or with only one previous positive reaction does not cause active sensitization and can be performed with minimal risk.

  5. Cost-of-illness of patients with contact dermatitis in Denmark.

    PubMed

    Saetterstrøm, Bjørn; Olsen, Jens; Johansen, Jeanne Duus

    2014-09-01

    Contact dermatitis is a frequent occupational and non-occupational skin disease. To investigate the effects of contact dermatitis on labour market affiliation and societal costs in terms of healthcare costs and production loss. A total of 21 441 patients patch tested either in hospital departments or at dermatological clinics in the period 2004-2009 were included in the study. The analyses were stratified by children (age 0-15 years), occupational contact dermatitis (age 16-65 years), and non-occupational dermatitis (age ≥ 16 years). Controls were selected from a 30% random sample of the population. Individual encrypted data were retrieved on healthcare utilization, socio-demographics, education, labour market affiliation and transfer payments from public registers in Denmark for cases and controls. Attributable healthcare costs for 4 years prior to patch testing (1 year for children) and the year after patch testing were €959 for children, €724 for occupational contact dermatitis, and €1794 for non-occupational dermatitis. Productivity costs for the same period were €10 722 for occupational contact dermatitis and €3074 for non-occupational contact dermatitis. The main findings of this study were that there were statistically significant attributable healthcare costs for both children and adults, and statistically significant productivity loss for adults. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Rivastigmine transdermal patch and physical exercises for Alzheimer's disease: a randomized clinical trial.

    PubMed

    Aguiar, Paula; Monteiro, Larissa; Feres, Ana; Gomes, Irênio; Melo, Ailton

    2014-01-01

    To determine the effects of rivastigmine patch associated with physical exercise versus rivastigmine patch alone in quality of life (QOL), cognition, activities of daily living (ADL) and functional mobility in Alzheimer's disease (AD)subjects. A randomized, controlled, single-blinded trial was conducted in 40 patients with mild to moderate stages of AD. All patients were daily treated with rivastigmine transdermal patch at a stable dose of 4.6 mg and randomized into two groups: physical exercises or control. The exercise program consisted of aerobic, flexibility, strength and balance movements, twice a week for 6 months. Main outcomes were Quality of Life in Alzheimer's disease scale (QOL), Activities of Daily Living Questionnaire (ADL), Mini-Mental State Examination (MMSE) and "Time Up and Go Test". Thirty-four patients completed the study. After 6 months, there was a significant improvement in QOL of patients randomized to physical exercise group (P< 0.05). In both groups, there was an improvement on caregivers QOL (P>0.05). When considering cognitive functions, there was no difference between groups. The ability to perform ADL worsened in the group enrolled to RTP alone. There was an improvement in functional mobility in the group treated with RTP. Our results suggest that the association between physical exercises and RTP improves QOL in patients with AD. Cognition remained unchanged in both groups. Regarding the effect of physical exercises in ADL, further trials are necessary to confirm these results.

  7. Two decades of occupational (meth)acrylate patch test results and focus on isobornyl acrylate.

    PubMed

    Christoffers, Wietske A; Coenraads, Pieter-Jan; Schuttelaar, Marie-Louise A

    2013-08-01

    Acrylates constitute an important cause of occupational contact dermatitis. Isobornyl acrylate sensitization has been reported in only 2 cases. We encountered an industrial process operator with occupational contact dermatitis caused by isobornyl acrylate. (i) To investigate whether it is relevant to add isobornyl acrylate to the (meth)acrylate test series. (ii) To report patients with (meth)acrylate contact allergy at an occupational dermatology clinic. Our patch test database was screened for positive reactions to (meth)acrylates between 1993 and 2012. A selected group of 14 patients was tested with an isobornyl acrylate dilution series: 0.3%, 0.1%, 0.033%, and 0.01%. Readings were performed on D2, D3, and D7. One hundred and fifty-one patients were tested with our (meth)acrylate series; 24 had positive reactions. Most positive reactions were to 2-hydroxypropyl acrylate, 2-hydroxyethyl acrylate, 2-hydroxypropyl methacrylate, and diethyleneglycol diacrylate. Hypothetical screening with 2-hydroxypropyl acrylate, ethyleneglycol dimethacrylate, ethoxylated bisphenol A glycol dimethacrylate and trimethylolpropane triacrylate identified 91.7% of the 24 patients. No positive reactions were observed in 14 acrylate-positive patients tested with the isobornyl acrylate dilution series. The 0.3% isobornyl acrylate concentration induced irritant reactions in 3 patients. We report a rare case of allergic contact dermatitis caused by isobornyl acrylate. However, this study provides insufficient support for isobornyl acrylate to be added to a (meth)acrylate series. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. TU-AB-BRA-02: An Efficient Atlas-Based Synthetic CT Generation Method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Han, X

    2016-06-15

    Purpose: A major obstacle for MR-only radiotherapy is the need to generate an accurate synthetic CT (sCT) from MR image(s) of a patient for the purposes of dose calculation and DRR generation. We propose here an accurate and efficient atlas-based sCT generation method, which has a computation speed largely independent of the number of atlases used. Methods: Atlas-based sCT generation requires a set of atlases with co-registered CT and MR images. Unlike existing methods that align each atlas to the new patient independently, we first create an average atlas and pre-align every atlas to the average atlas space. When amore » new patient arrives, we compute only one deformable image registration to align the patient MR image to the average atlas, which indirectly aligns the patient to all pre-aligned atlases. A patch-based non-local weighted fusion is performed in the average atlas space to generate the sCT for the patient, which is then warped back to the original patient space. We further adapt a PatchMatch algorithm that can quickly find top matches between patches of the patient image and all atlas images, which makes the patch fusion step also independent of the number of atlases used. Results: Nineteen brain tumour patients with both CT and T1-weighted MR images are used as testing data and a leave-one-out validation is performed. Each sCT generated is compared against the original CT image of the same patient on a voxel-by-voxel basis. The proposed method produces a mean absolute error (MAE) of 98.6±26.9 HU overall. The accuracy is comparable with a conventional implementation scheme, but the computation time is reduced from over an hour to four minutes. Conclusion: An average atlas space patch fusion approach can produce highly accurate sCT estimations very efficiently. Further validation on dose computation accuracy and using a larger patient cohort is warranted. The author is a full time employee of Elekta, Inc.« less

  9. Hydroxyisohexyl 3-cyclohexene carboxaldehyde- known as Lyral: quantitative aspects and risk assessment of an important fragrance allergen.

    PubMed

    Johansen, J D; Frosch, P J; Svedman, C; Andersen, K E; Bruze, M; Pirker, C; Menné, T

    2003-06-01

    Hydroxyisohexyl 3-cyclohexene carboxaldehyde, also known as Lyral, is a fragrance ingredient identified as the cause of contact allergic reactions in 2-3% of eczema patients undergoing patch testing. Lyral has been included in the standard patch test series in many clinics due to its importance as an allergen. It has been used without restrictions in cosmetic products, until now. In the present study, the dose-response relationship of Lyral contact allergy was studied with doses relevant for normal exposure in cosmetic products. 18 eczema patients, who previously had given a positive patch test to Lyral 5% petrolatum, were included along with 7 control subjects. All cases were tested with a serial dilution of Lyral in ethanol 6% to 6 p.p.m and subjected to a 2-week, repeated open application test with a low dose of Lyral in ethanol. In the case of no reaction, this was followed by another 2 weeks of testing with a higher dose. The test was performed at the volar aspect of the forearm. In 16 of 18 cases (89%), a positive use test developed, 11 reacting to the low and 5 to the high concentration. None reacted to the vehicle control of ethanol applied to the contralateral arm. All controls were negative to both the test solutions of Lyral and the ethanol control. The difference between the test and the control group was statistically significant (Fisher's test, P < 0.001). It is concluded that Lyral at the current usage levels is inducing sensitization in the community. The same levels were shown to elicit allergic contact dermatitis in almost all sensitized individuals. A significant reduction in usage concentrations is recommended to prevent contact allergic reactions.

  10. Tolerability of the capsaicin 8% patch following pretreatment with lidocaine or tramadol in patients with peripheral neuropathic pain: A multicentre, randomized, assessor-blinded study

    PubMed Central

    Jensen, TS; Høye, K; Fricová, J; Vanelderen, P; Ernault, E; Siciliano, T; Marques, S

    2014-01-01

    Background Application of the capsaicin 8% patch is associated with treatment-related discomfort. Consequently, pretreatment for 60 min with anaesthetic cream is recommended; however, this may be uncomfortable and time consuming. Methods We conducted a multicentre, randomized (1:1), assessor-blinded study in patients with peripheral neuropathic pain to assess tolerability of the capsaicin patch following topical lidocaine (4%) or oral tramadol (50 mg) pretreatment. The primary endpoint was the proportion of patients tolerating capsaicin patch application (ability to receive ≥90% of a 60-min application). Numeric Pain Rating Scale (NPRS) scores were assessed before, during and after treatment. Results Overall, 122 patients were included (61 per arm). The capsaicin patch was tolerated by 121 patients. Tolerability of the capsaicin patch was similar following pretreatment with lidocaine and tramadol. Following patch application, pain levels increased up to 55 min (change from baseline of 1.3 for lidocaine and 1.4 for tramadol). After patch removal, tramadol-treated patients experienced greater pain relief up to the end of day 1; in the evening, mean changes in NPRS scores from baseline were 0 for lidocaine and −1 for tramadol. Proportions of patients reporting increases of ≥2 NPRS points or >33% from baseline at one or more time point(s) on the day of treatment were similar between arms. Adverse event incidence was comparable between arms. Conclusions Capsaicin 8% patch tolerability was similar in the two arms, with comparable results for most secondary endpoints. Tramadol given 30 min before patch application should be considered as an alternative pretreatment option in patients receiving capsaicin patch treatment. What's already known about this topic? Application of topical capsaicin, a treatment for peripheral neuropathic pain conditions associated with allodynia, can cause painful discomfort. Therefore, a 60-min application of local anaesthetic cream before capsaicin 8% patch treatment was originally recommended. What does this study add? Oral analgesic pretreatment may reduce overall capsaicin patch treatment time and potential unpleasantness associated with applying a topical agent to an allodynic area. Based on LIFT data showing similar tolerability to capsaicin patch regardless of pretreatment method, the European Medicines Agency has issued a type II variation stating: treatment area may be pretreated with a topical anaesthetic or an oral analgesic may be given prior to patch application. PMID:24664539

  11. Sources of sensitization, cross-reactions, and occupational sensitization to topical anaesthetics among general dermatology patients.

    PubMed

    Jussi, Liippo; Lammintausta, Kaija

    2009-03-01

    Contact sensitization to local anaesthetics is often from topical medicaments. Occupational sensitization to topical anaesthetics may occur in certain occupations. The aim of the study was to analyse the occurrence of contact sensitization to topical anaesthetics in general dermatology patients. Patch testing with topical anaesthetics was carried out in 620 patients. Possible sources of sensitization and the clinical histories of the patients are analysed. Positive patch test reactions to one or more topical anaesthetics were seen in 25/620 patients. Dibucaine reactions were most common (20/25), and lidocaine sensitization was seen in two patients. Six patients had reactions to ester-type and/or amide-type anaesthetics concurrently. Local preparations for perianal conditions were the most common sensitizers. One patient had developed occupational sensitization to procaine with multiple cross-reactions and with concurrent penicillin sensitization from procaine penicillin. Dibucaine-containing perianal medicaments are the major source of contact sensitization to topical anaesthetics. Although sensitization to multiple anaesthetics can be seen, cross-reactions are possible. Contact sensitization to lidocaine is not common, and possible cross-reactions should be determined when reactions to lidocaine are seen. Occupational procaine sensitization from veterinary medicaments is a risk among animal workers.

  12. Implantation of a cone-shaped double-fixed patch increases abdominal space and prevents recurrence of large defects in congenital diaphragmatic hernia.

    PubMed

    Loff, Steffan; Wirth, Hartmut; Jester, Iwgo; Hosie, Stuart; Wollmann, Carmen; Schaible, Thomas; Ataman, Ozge; Waag, Karl-Ludwig

    2005-11-01

    Large defects in patients with congenital diaphragmatic hernia (CDH) are frequently closed with a polytetrafluoroethylene patch (PTFE). Intraoperative problems include lack of abdominal domain for the reduction of organs and closure of the abdominal wall. Main surgical postoperative complication is the recurrence of the hernia. We suggest a new and easy method of patch implantation, improving these problems, and report first follow-up results. In our clinic, 103 children with CDH were treated, and 87 children underwent reconstruction of the diaphragm in the 5 years between 1998 and 2002. In 52 patients, a patch implantation had to be performed. We have been optimizing our complete pediatric and surgical procedure and present a new standardized technique of preparation and implantation of a PTFE patch. The flat patch is folded to a 90 degrees cone. The cone is fixed in its form with few single stitches. It is implanted with an overlapping border of 1 cm circumferentially. The border is separately fixed with absorbable single stitches to keep from rolling up. The rough side of the patch points toward the rim of the diaphragm to enable ingrowth of the connective tissue. In a 1-year follow-up study, the recurrences in the 3 following groups of PTFE patches were studied: conventional implantation (simple patch without overlapping border), patch with separately fixed overlapping border, and cone-shaped patch with overlapping separately fixed border. Thirty-three patients were included in the study. After conventional PTFE-patch implantation, 6 (46%) of 13 patients developed reherniation. After PTFE-patch implantation with separately fixed overlapping border, 1 (11%) of 9 patients had a recurrent hernia. In the group with the PTFE-cone implantation, 1 (9%) of 11 patients developed a recurrence. Meanwhile, another 20 CDH patients received implantation of a cone-shaped patch, and no further recurrence occurred up to now. With the additional space (20 mL) provided by the cone-shaped patch, the closure of the abdomen was easier, and the fundus had intraoperatively a physiological position. This optimized patch implantation technique in large diaphragmatic defects offers considerable advantages especially regarding recurrence of the hernia and closure of the abdomen, which are currently the most challenging surgical problems. 1. The cone-shaped 3-dimensional patch increases abdominal capacity. 2. Redundant chest capacity is reduced, and the reconstructed diaphragm shows a physiological shape. 3. The dome of the patch allows a physiological position of the gastric fundus and a normal Hiss angle, thus preventing gastroesophageal reflux. 4. Additional safety of the implantation is achieved by separate fixation of the overlapping border of the cone, preventing recurrence.

  13. Octylisothiazolinone, an additional cause of allergic contact dermatitis caused by leather: case series and potential implications for the study of cross-reactivity with methylisothiazolinone.

    PubMed

    Aerts, Olivier; Meert, Hans; Romaen, Elien; Leysen, Julie; Matthieu, Lucretia; Apers, Sandra; Lambert, Julien; Goossens, An

    2016-11-01

    Octylisothiazolinone (OIT) is used as an antifungal agent by the leather industry. To show sensitization to OIT from leather, and to highlight the potential implications when cross-reactivity between OIT and methylisothiazolinone (MI) is studied. Two patients with allergic contact dermatitis caused by a leather belt and shoes, respectively, were patch tested with methylchloroisothiazolinone (MCI)/MI, MI, MCI, OIT, and benzisothiazolinone (BIT). High-performance liquid chromatography with ultraviolet detection (HPLC-UV) was used to detect isothiazolinone derivatives in leather goods. Additionally, files of OIT-sensitized patients, observed at the KU Leuven department during the period 1990-2015, were retrospectively analysed. Both patients had been primarily sensitized to OIT, but the diagnosis in one of them could be achieved only when a higher patch test concentration of OIT (1000 ppm pet.) was used. HPLC-UV confirmed the presence of OIT in their leather goods. Non-relevant sensitization to MI was noted in both cases. Four additional cases of OIT sensitization from leather could be retrieved from the KU Leuven database. Non-occupational sensitization to OIT from leather may occur. Patch test concentrations of >250 ppm pet. may be necessary for diagnosis, and to show cross-reactivity with MI. Safer use limits for OIT in the leather industry may be needed. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Transdermal nicotine patches for eosinophilic pustular folliculitis.

    PubMed

    Yoshifuku, Asuka; Higashi, Yuko; Matsushita, Shigeto; Kawai, Kazuhiro; Kanekura, Takuro

    2013-09-01

    We previously reported the clinical effectiveness of transdermal nicotine patches for the treatment of skin disorders with eosinophilic infiltration such as Kimura's disease, erythema nodosum and eosinophilic pustular folliculitis (EPF). We assessed the efficacy and safety of transdermal nicotine patches for EPF. We treated eight patients with EPF with transdermal nicotine patches and evaluated the treatment response by performing overall lesional assessment. Excellent 77and good responses were obtained in five and one patient(s), respectively. In the other two patients, the lesions remained unchanged. No severe adverse effects were observed. Our results suggest that transdermal nicotine patches may be useful and safe in the treatment of EPF. © 2013 Japanese Dermatological Association.

  15. Use of the pulsed infrared diode laser (904 nm) in the treatment of alopecia areata.

    PubMed

    Waiz, Makram; Saleh, Anmar Z; Hayani, Raafa; Jubory, Samar O

    2006-04-01

    Alopecia areata is a rapid and complete loss of hair in one or several patches, usually on the scalp, affecting both males and females equally. It is thought to be an autoimmune disease which is treated with different modalities with variable success. Laser treatment of different wavelengths has been used in the management of this problem. To study the effect of the pulsed infrared diode laser (904 nm) in the treatment of alopecia areata.Methods. Sixteen patients with 34 resistant patches that had not responded to different treatment modalities for alopecia areata were enrolled in this study. In patients with multiple patches, one patch was left as a control for comparison. Patients were treated on a four-session basis, once a week, with a pulsed diode laser (904 nm) at a pulse rate of 40/s. A photograph was taken of each patient before and after treatment. The treated patients were 11 males (68.75%) and five females (31.25%). Their ages ranged between 4 and 50 years with a mean of 26.6+/-SD of +/-13.8, and the durations of their disease were between 12 months and 6 years with a mean of 13.43+/-SD of +/-18.34. Regrowth of hair was observed in 32 patches (94%), while only two patches (6%) failed to show any response. No regrowth of hair was observed in the control patches. The regrowth of hair appeared as terminal hair with its original color in 29 patches (90.6%), while three patches (9.4%) appeared as a white villous hair. In patients who showed response, the response was detected as early as 1 week after the first session in 24 patches (75%), while eight patients (25%) started to show response from the second session. The pulsed infrared diode laser is an effective mode of therapy with a high success rate for resistant patches of alopecia areata.

  16. Positive patch test reactions to oxidized limonene: exposure and relevance.

    PubMed

    Bråred Christensson, Johanna; Andersen, Klaus E; Bruze, Magnus; Johansen, Jeanne D; Garcia-Bravo, Begoña; Gimenez Arnau, Ana; Goh, Chee-Leok; Nixon, Rosemary; White, Ian R

    2014-11-01

    R-Limonene is a common fragrance terpene found in domestic and industrial products. R-Limonene autoxidizes on air exposure, and the oxidation products can cause contact allergy. In a recent multicentre study, 5.2% (range 2.3-12.1%) of 2900 patients showed a positive patch test reaction to oxidized R-limonene. To study the exposure to limonene among consecutive dermatitis patients reacting to oxidized R-limonene in an international setting, and to assess the relevance of the exposure for the patients' dermatitis. Oxidized R-limonene 3.0% (containing limonene hydroperoxides at 0.33%) in petrolatum was tested in 2900 consecutive dermatitis patients in Australia, Denmark, the United Kingdom, Singapore, Spain, and Sweden. A questionnaire assessing exposure to limonene-containing products was completed. Overall, exposure to products containing limonene was found and assessed as being probably relevant for the patients' dermatitis in 36% of the limonene-allergic patients. In Barcelona and Copenhagen, > 70% of the patients were judged to have had an exposure to limonene assessed as relevant. Oxidized R-limonene is a common fragrance allergen, and limonene was frequently found in the labelling on the patients' products, and assessed as relevant for the patients' dermatitis. A large number of domestic and occupational sources for contact with R-limonene were identified. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Trichloroethylene Hypersensitivity Syndrome Is Potentially Mediated through Its Metabolite Chloral Hydrate.

    PubMed

    Huang, Yongshun; Xia, Lihua; Wu, Qifeng; Zeng, Zifang; Huang, Zhenlie; Zhou, Shanyu; Jin, Jiachun; Huang, Hanlin

    2015-01-01

    We documented previously the entity of trichloroethylene (TCE) hypersensitivity syndrome (THS) in occupational workers. To identify the culprit causative compound, determine the type of hypersensitivity of THS, and establish a screening test for subjects at risk of THS. TCE and its main metabolites chloral hydrate (CH), trichloroethanol (TCOH) and trichloroacetic acid (TCA) were used as allergens at different concentrations in skin patch tests. The study included 19 case subjects diagnosed with occupational THS, 22 control healthy workers exposed to TCE (exposure >12 weeks), and 20 validation new workers exposed to TCE for <12 weeks free of THS. All subjects were followed-up for 12 weeks after the patch test. The highest patch test positive rate in subjects with THS was for CH, followed by TCOH, TCA and TCE. The CH patch test positive rate was 100% irrespective of CH concentrations (15%, 10% and 5%). The TCOH patch test positive rate was concentration-dependent (89.5%, 73.7% and 52.6% for 5%, 0.5% and 0.05%, respectively). Lower patch test positive rates were noted for TCA and TCE. All patch tests (including four allergens) were all negative in each of the 22 control subjects. None of the subjects of the validation group had a positive 15% CH patch test. Chloral hydrate seems to be the culprit causative compound of THS and type IV seems to be the major type of hypersensitivity of THS. The CH patch test could be potentially useful for screening workers at risk of THS.

  18. Epoxy-based production of wind turbine rotor blades: occupational contact allergies.

    PubMed

    Pontén, Ann; Carstensen, Ole; Rasmussen, Kurt; Gruvberger, Birgitta; Isaksson, Marléne; Bruze, Magnus

    2004-03-01

    An industry producing rotor blades for wind turbines with an epoxy-based technology had experienced an increasing number of workers with dermatitis, among whom the frequency of occupational contact allergy (OCA) was suspected to be underestimated. To investigate the frequency of OCA by patch-testing with a specially profiled occupational patch test series. In a blinded study design, 603 workers were first interviewed and thereafter clinically examined. Based on a history of work-related skin disease, clinical findings of dermatitis, or both, 325 (53.9%) of the workers were patch-tested with an occupational patch test series and the European Standard patch test series. Of the 603 investigated workers, 10.9% had OCA and 5.6% had contact allergy to epoxy resin in the standard test series. Contact allergy to amine hardeners/catalysts was found in 4.1% of the workers. Among the workers with OCA, 48.5% reacted to work material other than epoxy resin in the European Standard patch test series. Approximately 50% of the workers with OCA would not have been detected if only the European Standard patch test series had been used.

  19. Allergic Maculo-Papular Exanthema Due To Terbinafine

    PubMed Central

    Koch, André; Tchernev, Georgi; Wollina, Uwe

    2017-01-01

    We report on a 76-year-old male patient who developed a maculopapular generalised exanthema due to terbinafine. Prick test was negative; patch test revealed a positive reaction after 48 h confirming the delayed-type allergic reaction. Non-pustular exanthema has only rarely been reported for terbinafine. PMID:28785353

  20. Formulation, in vitro and in vivo evaluation of transdermal patches containing risperidone.

    PubMed

    Aggarwal, Geeta; Dhawan, Sanju; Hari Kumar, S L

    2013-01-01

    The efficacy of oral risperidone treatment in prevention of schizophrenia is well known. However, oral side effects and patient compliance is always a problem for schizophrenics. In this study, risperidone was formulated into matrix transdermal patches to overcome these problems. The formulation factors for such patches, including eudragit RL 100 and eudragit RS 100 as matrix forming polymers, olive oil, groundnut oil and jojoba oil in different concentrations as enhancers and amount of drug loaded were investigated. The transdermal patches containing risperidone were prepared by solvent casting method and characterized for physicochemical and in vitro permeation studies through excised rat skin. Among the tested preparations, formulations with 20% risperidone, 3:2 ERL 100 and ERS 100 as polymers, mixture of olive oil and jojoba oil as enhancer, exhibited greatest cumulative amount of drug permeated (1.87 ± 0.09 mg/cm(2)) in 72 h, so batch ROJ was concluded as optimized formulation and assessed for pharmacokinetic, pharmacodynamic and skin irritation potential. The pharmacokinetic characteristics of the optimized risperidone patch were determined using rabbits, while orally administered risperidone in solution was used for comparison. The calculated relative bioavailability of risperidone transdermal patch was 115.20% with prolonged release of drug. Neuroleptic efficacy of transdermal formulation was assessed by rota-rod and grip test in comparison with control and marketed oral formulations with no skin irritation. This suggests the transdermal application of risperidone holds promise for improved bioavailability and better management of schizophrenia in long-term basis.

  1. Increase in sensitization to oil of turpentine: recent data from a multicenter study on 45,005 patients from the German-Austrian Information Network of Departments of Dermatology (IVDK).

    PubMed

    Treudler, R; Richter, G; Geier, J; Schnuch, A; Orfanos, C E; Tebbe, B

    2000-02-01

    Contact allergy to oil of turpentine was reported to have become rare. However, the evaluation of standardized data of 45,005 patients tested 1992-1997 in 30 Dermatological Centers associated with the German-Austrian Information Network of Departments of Dermatology (IVDK) showed an increase in positive patch test reactions to turpentine from 0.5% during the years 1992-1995, up to 1.7% in 1996 and 3.1% in 1997. In particular, 17,347 patients tested in 1996-1997 were evaluated in detail by comparing 431 individuals with positive patch test reactions with the rest of the group found negative to turpentine. Using the so-called MOAHLFA index, the following characteristics were shown. Turpentine allergy (a) was found to be significantly less frequent in men and in patients with occupational dermatitis, (b) showed no difference in its association with atopic dermatitis, (c) patients with turpentine allergy had significantly less symptoms of the hands, more symptoms of the legs or in the face and (d) were significantly more often aged over 60 years. Also, patients sensitized to turpentine had increased rates of additional sensitizations. The definite reason for the increase in turpentine sensitization in the population tested here is not clear. Therefore, a detailed exposure analysis is necessary; the new increase in turpentine allergies may be due to popular topical remedies or household chemicals.

  2. Results of patch testing with fragrance mix 1, fragrance mix 2, and their ingredients, and Myroxylon pereirae and colophonium, over a 21-year period.

    PubMed

    Nardelli, Andrea; Carbonez, An; Drieghe, Jacques; Goossens, An

    2013-05-01

    The frequency of fragrance contact allergy has shown a fluctuating trend over the years. To describe the frequency of positive reactions to the baseline screening agents and fragrance mix (FM) 1 and 2 components, to determine trends of the latter over the years, and to evaluate simultaneous reactions. This was a cross-sectional study on patch test results of 13 332 patients from January 1990 to December 2011. Of the total population, 9.6% reacted positively to FM 1, and 6% of 3416 tested with FM 2 reacted positively. Of those tested with both, 30.4% of 349 FM 1-positive patients reacted to FM 2, and 51.7% of 205 FM 2-positive patients reacted to FM 1. Hydroxyisohexyl 3-cyclohexene carboxaldehyde (HICC) and FM 2 were tested simultaneously in 3401 patients: 6 reacted to HICC alone. Nine hundred and forty patients were tested with FM 1 ingredients and 205 with FM 2 ingredients; Evernia prunastri was the most frequent FM 1 allergen, and HICC was the most frequent FM 2 allergen. Simultaneous reactions were frequently observed. Fragrance-allergic subjects often show multiple positive reactions, some of which are highly significantly associated. Recently, there has been a decreasing trend in positivity for both Evernia prunastri and HICC, whereas a slight increase for cinnamyl alcohol has been observed. © 2013 John Wiley & Sons A/S.

  3. Lyral is an important sensitizer in patients sensitive to fragrances.

    PubMed

    Frosch, P J; Johansen, J D; Menné, T; Rastogi, S C; Bruze, M; Andersen, K E; Lepoittevin, J P; Giménez Arnau, E; Pirker, C; Goossens, A; White, I R

    1999-12-01

    Contact allergy to fragrances is a common problem world-wide. The currently used fragrance mix (FM) for patch testing has only eight constituents and does not identify all fragrance-allergic patients. As perfumes may contain 100 or more substances, the search for markers for allergy continues. The synthetic fragrance 4-(4-hydroxy-4-methylpentyl)-3-cyclohexene carboxaldehyde (Lyral) was tested together with the FM and 11 other fragrance substances on consecutive patients in six European departments of dermatology. All patients were carefully questioned regarding a history of reactions to scented products in the past and were grouped into four categories: 'certain', 'probable', 'questionable' and 'none'. Lyral (5% in petrolatum) gave a positive reaction in 2.7% of 1855 patients (range 1.2-17%) and ranked next to 11.3% with FM allergy. Twenty-four patients reacted to both Lyral and FM, but 21 (1.1%) reacted positively only to Lyral. Of 124 patients with a 'certain' history, 53.2% reacted to the FM and a further 7.2% to Lyral only. If any kind of history of fragrance intolerance was given, 80% (40 of 50) of Lyral positive patients had a 'positive' history while only 58.6% (123 of 210) of FM positive patients had such a history; this difference was significant at P < 0.01. Lyral was identified by gas chromatography-mass spectrometry in some products which had caused an allergic contact dermatitis in four typical patients who showed a patch test positive to Lyral and negative or doubtful to FM. In conclusion, we recommend the testing of 5% Lyral (in petrolatum) in patients suspected of contact dermatitis.

  4. Sweat testing for the detection of atomoxetine from paediatric patients with attention deficit/ hyperactivity disorder: application to clinical practice.

    PubMed

    Marchei, Emilia; Papaseit, Esther; Garcia-Algar, Oscar; Bilbao, Amaia; Farré, Magí; Pacifici, Roberta; Pichini, Simona

    2013-03-01

    Atomoxetine (ATX) is a selective norepinephrine reuptake inhibitor approved since 2002 for the treatment of attention deficit hyperactivity disorder (ADHD) in children, adolescents, and adults as an alternative treatment to methylphenidate. Within the framework of a project evaluating the use of alternative biological matrices for therapeutic monitoring of psychoactive drugs in paediatric and non-paediatric individuals, the excretion of ATX and its principal metabolites has been recently studied in oral fluid and hair. The aim of this study was to describe the excretion profile of ATX and its metabolites 4-hydroxyatomoxetine (4-OH-ATX) and N-desmethylatomoxetine (N-des-ATX) in sweat following the administration of different dosage regimens (60, 40, 35, and 18 mg/day) of ATX to six paediatric patients. Sweat patches were applied to the back of each participant and removed at timed intervals. ATX and its metabolites were measured in patches using a previously validated liquid chromatography-tandem mass spectrometric (LC-MS/MS) method. Independently from the administered dose, ATX appeared in the sweat patches 1 h post administration and reached its maximum concentration generally at 24 h. Peak ATX concentrations ranged between 2.31 and 40.4 ng/patch and did not correlate with the administered drug dose, or with body surface area. Total ATX excreted in sweat ranged between 0.008 and 0.121 mg, corresponding to 0.02 and 0.3% of the administered drug. Neither 4-OH-ATX, nor N-des-ATX was detected in either of the collected sweat patches. Measuring ATX in sweat patches can provide information on cumulative drug use from patch application until removal. Copyright © 2012 John Wiley & Sons, Ltd.

  5. Perianal Dermatitis.

    PubMed

    Agulló-Pérez, Alfredo-Daniel; Hervella-Garcés, Marcos; Oscoz-Jaime, Saioa; Azcona-Rodríguez, Maialen; Larrea-García, Mónica; Yanguas-Bayona, Juan-Ignacio

    Perianal complaints are often consulted in dermatology clinics, and in many cases, a conclusive diagnosis is not easily made. The aim of this study was to study and identify the epidemiological, clinical, and contact allergy features of patients with perianal dermatitis who attended at a contact dermatitis unit in a tertiary hospital in Spain. Adult patients with long-lasting (>4 weeks) perianal dermatitis were recruited during the past 10 years for investigation and follow-up. Every patient underwent a diagnostic workup consisting of dermatological exploration and patch tests with the standard and specific series, as well as the patients' own products. General surgical exploration was also performed in some patients. One hundred twenty-four patients were included. The MOAHLFA index was as follows: 43.5, 0, 4.8, 11.3, 1.6, 8.1, and 75. The main final diagnoses were allergic contact dermatitis (32.3%), psoriasis (24.2%), irritant contact dermatitis (17.7%), and lichen simplex (neurodermatitis) (10%). Eighty-one patients (66.1%) showed 1 or more positive reactions, and in 52 patients (43%), positive reactions relevant to the present disease were found. Contact allergy in patients with long-lasting perianal complaints is frequent. It is mandatory for these patients to be referred to a dermatologist for an adequate evaluation and patch testing. Methylchloroisothiazolinone/methylisothiazolinone seems as the most common allergen implicated in perianal contact dermatitis.

  6. Trichloroethylene Hypersensitivity Syndrome Is Potentially Mediated through Its Metabolite Chloral Hydrate

    PubMed Central

    Huang, Yongshun; Xia, Lihua; Wu, Qifeng; Zeng, Zifang; Huang, Zhenlie; Zhou, Shanyu; Jin, Jiachun; Huang, Hanlin

    2015-01-01

    Background We documented previously the entity of trichloroethylene (TCE) hypersensitivity syndrome (THS) in occupational workers. Objectives To identify the culprit causative compound, determine the type of hypersensitivity of THS, and establish a screening test for subjects at risk of THS. Methods TCE and its main metabolites chloral hydrate (CH), trichloroethanol (TCOH) and trichloroacetic acid (TCA) were used as allergens at different concentrations in skin patch tests. The study included 19 case subjects diagnosed with occupational THS, 22 control healthy workers exposed to TCE (exposure >12 weeks), and 20 validation new workers exposed to TCE for <12 weeks free of THS. All subjects were followed-up for 12 weeks after the patch test. Results The highest patch test positive rate in subjects with THS was for CH, followed by TCOH, TCA and TCE. The CH patch test positive rate was 100% irrespective of CH concentrations (15%, 10% and 5%). The TCOH patch test positive rate was concentration-dependent (89.5%, 73.7% and 52.6% for 5%, 0.5% and 0.05%, respectively). Lower patch test positive rates were noted for TCA and TCE. All patch tests (including four allergens) were all negative in each of the 22 control subjects. None of the subjects of the validation group had a positive 15% CH patch test. Conclusions Chloral hydrate seems to be the culprit causative compound of THS and type IV seems to be the major type of hypersensitivity of THS. The CH patch test could be potentially useful for screening workers at risk of THS. PMID:26020924

  7. Convolutional neural networks for the detection of diseased hearts using CT images and left atrium patches

    NASA Astrophysics Data System (ADS)

    Dormer, James D.; Halicek, Martin; Ma, Ling; Reilly, Carolyn M.; Schreibmann, Eduard; Fei, Baowei

    2018-02-01

    Cardiovascular disease is a leading cause of death in the United States. The identification of cardiac diseases on conventional three-dimensional (3D) CT can have many clinical applications. An automated method that can distinguish between healthy and diseased hearts could improve diagnostic speed and accuracy when the only modality available is conventional 3D CT. In this work, we proposed and implemented convolutional neural networks (CNNs) to identify diseased hears on CT images. Six patients with healthy hearts and six with previous cardiovascular disease events received chest CT. After the left atrium for each heart was segmented, 2D and 3D patches were created. A subset of the patches were then used to train separate convolutional neural networks using leave-one-out cross-validation of patient pairs. The results of the two neural networks were compared, with 3D patches producing the higher testing accuracy. The full list of 3D patches from the left atrium was then classified using the optimal 3D CNN model, and the receiver operating curves (ROCs) were produced. The final average area under the curve (AUC) from the ROC curves was 0.840 +/- 0.065 and the average accuracy was 78.9% +/- 5.9%. This demonstrates that the CNN-based method is capable of distinguishing healthy hearts from those with previous cardiovascular disease.

  8. Oxidized limonene and oxidized linalool - concomitant contact allergy to common fragrance terpenes.

    PubMed

    Bråred Christensson, Johanna; Karlberg, Ann-Therese; Andersen, Klaus E; Bruze, Magnus; Johansen, Jeanne D; Garcia-Bravo, Begoña; Giménez Arnau, Ana; Goh, Chee-Leok; Nixon, Rosemary; White, Ian R

    2016-05-01

    Limonene and linalool are common fragrance terpenes. Both oxidized R-limonene and oxidized linalool have recently been patch tested in an international setting, showing contact allergy in 5.2% and 6.9% of dermatitis patients, respectively. To investigate concomitant reactions between oxidized R-limonene and oxidized linalool in consecutive dermatitis patients. Oxidized R-limonene 3.0% (containing limonene hydroperoxides 0.33%) and oxidized linalool 6% (linalool hydroperoxides 1%) in petrolatum were tested in 2900 consecutive dermatitis patients in Australia, Denmark, Singapore, Spain, Sweden, and the United Kingdom. A total of 281 patients reacted to either oxidized R-limonene or oxidized linalool. Of these, 25% had concomitant reactions to both compounds, whereas 29% reacted only to oxidized R-limonene and 46% only to oxidized linalool. Of the 152 patients reacting to oxidized R-limonene, 46% reacted to oxidized linalool, whereas 35% of the 200 patients reacting to oxidized linalool also reacted to oxidized R-limonene. The majority of the patients (75%) reacted to only one of the oxidation mixtures, thus supporting the specificity of the reactions. The concomitant reactions to the two fragrance allergens suggest multiple sensitizations, which most likely reflect the exposure to the different fragrance materials in various types of consumer products. This is in accordance with what is generally seen for patch test reactions to fragrance materials. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Safety and efficacy of skin patches containing loxoprofen sodium in diabetic patients with overt nephropathy.

    PubMed

    Araki, Hisazumi; Kuwagata, Shogo; Soumura, Mariko; Yamahara, Kosuke; Morita, Yoshikata; Kume, Shinji; Isshiki, Keiji; Araki, Shin-ichi; Kashiwagi, Atsunori; Maegawa, Hiroshi; Uzu, Takashi

    2014-06-01

    Because oral nonsteroidal anti-inflammatory drugs (NSAIDs) have adverse effects on kidney function, patients with kidney diseases are administered these drugs as transdermal patches. Little is known about the effects of NSAID patches on renal function. We therefore assessed the effects of topical loxoprofen sodium on kidney function in type 2 diabetic patients with overt nephropathy. Twenty patients with type 2 diabetes and overt proteinuria and with knee and/or low back pain were treated with skin patches containing 100 mg loxoprofen on the knee or back for 24 h per day for 5 consecutive days. The degree of pain was assessed using a visual analogue scale (VAS). Blood and 24-h urine samples were obtained at baseline and at the end of the study. Glomerular filtration rate (GFR) was estimated from serum creatinine and cystatin C concentrations. The 20 patients consisted of 11 males and 9 females, of mean age 61.6 ± 13.9 years. Loxoprofen-containing patches significantly reduced VAS pain without affecting blood pressure, GFR or urinary prostaglandin E2 concentration. Serum concentrations of loxoprofen and its active trans-OH metabolite did not correlate with GFR. Loxoprofen-containing patches do not affect renal function in type 2 diabetic patients with overt nephropathy over a short-term period. Long-term studies are needed to clarify the safety of loxoprofen-containing patches in patients with chronic kidney diseases.

  10. Screening occupational contact allergy to bisphenol F epoxy resin.

    PubMed

    Aalto-Korte, Kristiina; Suuronen, Katri; Kuuliala, Outi; Henriks-Eckerman, Maj-Len; Jolanki, Riitta

    2014-09-01

    Epoxy resins based on diglycidyl ether of bisphenol F (DGEBF) are widely used as such in applications requiring chemical resistance, and also together with diglycidyl ether of bisphenol A resin (DGEBA-R). Concomitant patch test reactions to DGEBA-R and DGEBF resin (DGEBF-R) are common. Previous studies have yielded conflicting results on the frequency of independent DGEBF-R contact allergies. To report the results of over 11 years of screening with DGEBF-R. An in-house test substance of DGEBF-R (Epikote 862) was tested in the baseline patch test series, first at 1% and later at 0.25%. Test files were screened for allergic reactions to DGEBF-R and DGEBA-R, and the clinical records of positively reacting patients were analysed for occupation and exposure. Among 1972 patients, 66 (3.3%) reacted to DGEBF-R and 96 (4.9%) to DGEBA-R. Independent DGEBF-R allergies were seen in 5 patients only, and independent DGEBA-R allergies in 35. Specific exposure to DGEBF-R was found in 26 patients. The main occupational fields were the aircraft industry, the electrical and sports equipment industry, boat building, painting/floor coating, tile setting, and pipe relining. Independent contact allergies to DGEBF-R were rare, and screening with it was not found to be useful. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Pesticide patch test series for the assessment of allergic contact dermatitis among banana plantation workers in panama.

    PubMed

    Penagos, Homero; Ruepert, Clemens; Partanen, Timo; Wesseling, Catharina

    2004-09-01

    Irritant contact dermatitis and allergic contact dermatitis (ACD) are frequent among agricultural workers and require targeted interventions. Patch testing is necessary for differential diagnosis, but patch testing with pesticides is uncommon. This study explores the frequency of ACD and sensitization to pesticides among highly exposed banana plantation workers. Frequently and recently used pesticides on banana plantations in Divala, Panama, were documented. A pesticide patch test tray specific for this population was prepared. A structured interview was administered to 366 participants, followed by a complete skin examination. The pesticide patch test series, as well as a standard patch test series, was applied to 37 workers with dermatoses likely to be pesticide related and to 23 control workers without dermatoses. The pesticide patch tests identified 15 cases (41%) of ACD (20 positive reactions) among the 37 workers diagnosed with pesticide dermatosis. Three controls had allergic reactions to pesticides (4 positive reactions). The pesticides were carbaryl (5 cases), benomyl (4 cases), ethoprophos (3), chlorothalonil (2), imazalil (2), glyphosate (2), thiabendazole (2), chlorpyrifos (1), oxyfluorfen (1), propiconazole (1), and tridemorph (1). Ethoprophos and tridemorph had not been previously identified as sensitizers. Thus, the prevalence of ACD was 0.03 (15 of 366). On the basis of observed prevalences of positive patch-test reactions among the subgroups with and without dermatoses, we estimated that > or = 16% of the entire population may be sensitized to pesticides. Sensitization to pesticides among banana plantation workers is a frequent occupational health problem. Pesticide patch test trays should be used in assessing skin diseases in highly exposed workers.

  12. Urushiol Patch Test Using the T.R.U.E. TEST System.

    PubMed

    Kim, Yesul; Longenecker, Amy; ElSohly, Mahmoud A; Gul, Waseem; Hage, Raymond J; Hamann, Curtis P; Marks, James G

    Poison ivy, poison oak, and poison sumac are the most common causes of allergic contact dermatitis in North America. Although extensive efforts have been made to develop therapies that prevent and treat allergic contact dermatitis to these plants, there lacks an entirely effective method, besides complete avoidance. Efforts to develop a more effective preventive therapy, such as a vaccine, are ongoing. To accurately evaluate the efficacy of these new therapies, an appropriate assessment tool is needed. The aim of this study was to evaluate the safety and appropriate doses of urushiol required for a patch test based on the hydrogel delivery system of the Thin-Layer Rapid Use Epicutaneous Patch Test. Nine subjects were patch tested with various doses of urushiol and a negative control on day 0. Patch test sites were inspected for any local reaction on days 2, 4, 7, 14, and 21 after the initial exposure and graded by standard morphology. All 9 subjects did not have any significant adverse effects. The urushiol patch test using the hydrogel delivery method demonstrated urushiol sensitivity. All doses of urushiol resulted in a local reaction, and severity of reactions was correlated with dosage of urushiol used in the patch test.

  13. Patch testing in Australia: Is it adequate?

    PubMed

    Tizi, Stephanie; Nixon, Rosemary L

    2016-08-01

    Patch testing (PT) is essential for making the diagnosis of allergic contact dermatitis (ACD). However, the extent of PT undertaken by Australian dermatologists is unknown. The objectives of this study were to determine the rate and type of PT in Australia, the perceived obstacles to PT, and to explore the exposure to PT in dermatology training. Data were collected on private PT (analysing Medicare item numbers) and public hospital-based PT (estimated via verbal reports). An online survey on PT was sent to Fellows of the Australasian College of Dermatologists. It was found that total PT numbers, combining Medicare item number and public hospital data, were below the suggested optimum in all states and in Australia overall. Of the 173 respondents to the survey, 61% reported they patch tested and 78% reported they referred for PT. TrueTest was the most commonly used PT system, although it is known to be inadequate. Dermatologists who PT as registrars were significantly more likely to PT as consultants (P value = 0.0029). Cost, expertise required and staffing were considered major obstacles to performing PT. Accessibility and cost to the patient were common obstacles to referral. The combination of suboptimal PT rates and inadequate PT means that patients are missing out on being diagnosed with ACD in Australia. Increasing the exposure of registrars to PT, supporting specialised centres, the development of the Australian Baseline Series and the Contact Allergen Bank will, it is hoped, improve the rates of comprehensive PT in Australia. © 2015 The Australasian College of Dermatologists.

  14. Assessment of hypoallergenicity of ten skincare products.

    PubMed

    Brandt, Staci; Lio, Peter

    2014-03-01

    Sensitive skin is a common skin complaint frequently associated with skin diseases or adverse reactions to cosmetic products. Manufacturers have produced numerous products targeted for patients with sensitive skin and frequently label these products as being hypoallergenic. This term implies that the product may be less likely to cause an allergic reaction and be better suited for those with sensitive skin. However, there is no federal regulatory definition of this term and products may not have clinical support of their claim. Patch testing ingredients is frequently done to identify potential irritants; however, patch-testing product formulations may provide more realistic expectations about potential skin sensitivity and help support claims of hypoallergenicity. Ten skincare products were assessed for their sensitizing potential and hypoallergenicity in 14 repeat insult patch test clinical studies, involving over 2,000 subjects. In these studies, the products were deemed to be hypoallergenic if there was no evidence of sensitization or allergic reactions. The results from these trials demonstrated that all ten products were well tolerated, showed no sensitization or allergic reactions, and support claims of hypoallergenicity.

  15. Hydroxyisohexyl 3-cyclohexene carboxaldehyde allergy: relationship between patch test and repeated open application test thresholds.

    PubMed

    Fischer, L A; Menné, T; Avnstorp, C; Kasting, G B; Johansen, J D

    2009-09-01

    Hydroxyisohexyl 3-cyclohexene carboxaldehyde (HICC) is a synthetic fragrance ingredient. Case reports of allergy to HICC appeared in the 1980s, and HICC has recently been included in the European baseline series. Human elicitation dose-response studies performed with different allergens have shown a significant relationship between the patch-test threshold and the repeated open application test (ROAT) threshold, which mimics some real-life exposure situations. Fragrance ingredients are special as significant amounts of allergen may evaporate from the skin. The study aimed to investigate the relationship between elicitation threshold doses at the patch test and the ROAT, using HICC as the allergen. The expected evaporation rate was calculated. Seventeen HICC-allergic persons were tested with a dilution series of HICC in a patch test and a ROAT (duration up to 21 days). Seventeen persons with no HICC allergy were included as control group for the ROAT. Results The response frequency to the ROAT (in microg HICC cm(-2) per application) was significantly higher than the response frequency to the patch test at one of the tested doses. Furthermore the response rate to the accumulated ROAT dose was significantly lower at half of the doses compared with the patch test. The evaporation rate of HICC was calculated to be 72% over a 24-h period. The ROAT threshold in dose per area per application is lower than the patch test threshold; furthermore the accumulated ROAT threshold is higher than the patch test threshold, which can probably be explained by the evaporation of HICC from the skin in the open test.

  16. A 24-Week, Open-Label Extension Study to Investigate the Long-term Safety, Tolerability, and Efficacy of 13.3 mg/24 h Rivastigmine Patch in Patients With Severe Alzheimer Disease.

    PubMed

    Farlow, Martin R; Grossberg, George T; Sadowsky, Carl H; Meng, Xiangyi; Velting, Drew M

    2015-01-01

    The long-term safety, tolerability, and efficacy of high-dose 13.3 mg/24 h rivastigmine patch in severe Alzheimer disease was evaluated in a 24-week, open-label extension to the double-blind ACTION study. Safety and tolerability, and efficacy on the Alzheimer's Disease Cooperative Study-Activities of Daily Living scale-Severe Impairment Version (ADCS-ADL-SIV), Severe Impairment Battery (SIB), and ADCS-Clinical Global Impression of Change (ADCS-CGIC) were assessed. Overall, 197 patients continued on 13.3 mg/24 h patch; 199 uptitrated from 4.6 mg/24 h to 13.3 mg/24 h patch. The incidence of adverse events (AEs), serious AEs and discontinuations due to AEs was similar in patients who continued on, and patients who uptitrated to, 13.3 mg/24 h patch (AEs: 57.9% and 59.8%; serious AEs: 16.2% and 16.1%; discontinuations: 11.2% and 12.1%, respectively). Larger mean changes from double-blind baseline were observed in patients uptitrated on the ADCS-ADL-SIV (-4.6; SD=8.7) and SIB (-7.0; SD=16.6), than those who continued on 13.3 mg/24 h patch (-3.9; SD=8.0 and -4.7; SD=16.8, respectively). ADCS-CGIC scores were comparable. There were no clinically relevant between-group differences in safety and tolerability. Greater decline was observed in patients with delayed uptitration to high-dose 13.3 mg/24 h patch than patients who continued on high-dose patch.

  17. Contact dermatitis to cobalt chloride with an unusual mechanism.

    PubMed

    Arslan, Sevket; Aksan, Serkan; Ucar, Ramazan; Caliskaner, Ahmet Zafer

    2015-10-01

    Contact dermatitis is a frequent inflammatory skin disease. A suspected diagnosis is based on clinical symptoms, a plausible contact to allergens and a suitable history of dermatitis. Therefore, careful diagnosis by patch testing is of great importance because the patch testing is important to find out which allergen/material causes the complaints. Metallic allergens such as cobalt are among the most common causes of allergic contact dermatitis, but frequencies of contact dermatitis to these allergens may vary in different skin areas. Here, we report an unusual case of cobalt allergy on the skin contact with the prosthetic leg of a 30-year-old female patient. The patient developed maculopapular and vesicular lesions on her contact region of residual limb to prosthetic leg. She underwent standard patch testing, which resulted in a strong positive reaction to cobalt chloride. This case report may serve to remind doctors to be aware of potential allergic reactions to prostheses and to enable them to recognize a metal allergy if it appears. Prosthetists should also be reminded of potential allergic reactions. Cobalt can be used as an accelerator in making a prosthetic socket. Several cases have been reported concerning allergies to components of the prosthetic socket. This is the first report of sensitization to cobalt which is used in making a prosthetic leg. © The International Society for Prosthetics and Orthotics 2014.

  18. Allergic contact dermatitis caused by dimethylthiocarbamylbenzothiazole sulfide (DMTBS) in canvas shoes: in search of the culprit allergen.

    PubMed

    Schuttelaar, Marie L; Meijer, Joost M; Engfeldt, Malin; Lapeere, Hilde; Goossens, An; Bruze, Magnus; Persson, Christina; Bergendorff, Ola

    2018-01-01

    During rubber vulcanization, new compounds can be formed. To report a case of allergic shoe dermatitis in which the search for the allergen ultimately led to the identification of dimethylthiocarbamylbenzothiazole sulfide (DMTBS). A female presented with eczema on her feet after wearing Sperry Top Sider® canvas sneakers. Patch testing was performed with the European baseline series, additional series, shoe materials, and extracts of shoe materials. Thin-layer chromatography (TLC) was performed for additional patch testing, and high-performance liquid chromatography and gas chromatography-mass spectometry were used for chemical analysis. Positive reactions were found to thiuram mix (+), tetramethylthiuram monosulfide (TMTM) (+), shoe material (+), and shoe extracts in eth. (++) and acetone (+). The extracts did not contain TMTM or other components of thiuram mix. TLC strips yielded a positive reaction (+) to one spot, whereas chemical analysis gave a negative result. Thereafter, a similar sneaker from another patient with shoe dermatitis was analysed, and DMBTS was identified. New extracts of the shoe of our first patient were then also shown to contain DMTBS. DMTBS as culprit allergen was confirmed by positive patch testing with a dilution series with DMTBS. DMBTS was identified as the culprit allergen in shoe dermatitis, giving rise to compound allergy. The positive reaction to TMTM was considered to represent cross-reactivity. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Fragrance exposure in the UK: has there been a change in the last decade?

    PubMed

    Webber, L; Keith, D; Walker-Smith, P; Buckley, D A

    2018-06-26

    Fragrance allergy constitutes a significant public health problem that affects 1-2% of the general population and 6-13% of consecutively patch tested patients 1 . The European Union (EU) Scientific Committee on Consumer Safety (SCCS) independently advises the EU on its regulation of allergens such as fragrance. At present, a total of 26 fragrance allergens are subject to mandatory individual labelling on product packaging in the EU, including all 14 that form Fragrance Mixes 1 and 2 in the European and British Baseline patch test series. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  20. Attitudes about Advances in Sweat Patch Testing in Drug Courts: Insights from a Case Study in Southern California

    ERIC Educational Resources Information Center

    Polzer, Katherine

    2010-01-01

    Drug courts are reinventing the drug testing framework by experimenting with new methods, including use of the sweat patch. The sweat patch is a band-aid like strip used to monitor drug court participants. The validity and reliability of the sweat patch as an effective testing method was examined, as well as the effectiveness, meaning how likely…

  1. Responder analysis of a randomized comparison of the 13.3 mg/24 h and 9.5 mg/24 h rivastigmine patch.

    PubMed

    Molinuevo, José L; Frölich, Lutz; Grossberg, George T; Galvin, James E; Cummings, Jeffrey L; Krahnke, Tillmann; Strohmaier, Christine

    2015-01-01

    OPtimizing Transdermal Exelon In Mild-to-moderate Alzheimer's disease (OPTIMA) was a randomized, double-blind comparison of 13.3 mg/24 h versus 9.5 mg/24 h rivastigmine patch in patients with mild-to-moderate Alzheimer's disease who declined despite open-label treatment with 9.5 mg/24 h patch. Over 48 weeks of double-blind treatment, high-dose patch produced greater functional and cognitive benefits compared with 9.5 mg/24 h patch. Using OPTIMA data, a post-hoc responder analysis was performed to firstly, compare the proportion of patients demonstrating improvement or absence of decline with 13.3 mg/24 h versus 9.5 mg/24 h patch; and secondly, identify predictors of improvement or absence of decline. 'Improvers' were patients who improved on the Alzheimer's Disease Assessment Scale-cognitive subscale (ADAS-cog) by ≥4 points from baseline, and did not decline on the instrumental domain of the Alzheimer's Disease Cooperative Study-Activities of Daily Living scale (ADCS-IADL). 'Non-decliners' were patients who did not decline on either scale. Overall, 265 patients randomized to 13.3 mg/24 h and 271 to 9.5 mg/24 h patch met the criteria for inclusion in the intention-to-treat population and were included in the analyses. Significantly more patients were 'improvers' with 13.3 mg/24 h compared with 9.5 mg/24 h patch at Weeks 24 (44 (16.6%) versus 19 (7.0%); P < 0.001) and 48 (21 (7.9%) versus 10 (3.7%); P = 0.023). A significantly greater proportion of patients were 'non-decliners' with 13.3 mg/24 h compared with 9.5 mg/24 h patch at Week 24 (71 (26.8%) versus 44 (16.2%); P = 0.002). At Week 48, there was a trend in favor of 13.3 mg/24 h patch. Functional and cognitive assessment scores at double-blind baseline did not consistently predict effects at Weeks 24 or 48. More patients with mild-to-moderate Alzheimer's disease who are titrated to 13.3 mg/24 h rivastigmine patch at time of decline are 'improvers' or 'non-decliners' i.e. show responses on cognition and activities of daily living compared with patients remaining on 9.5 mg/24 h patch. Clinicaltrials.gov identifier: NCT00506415; registered July 20, 2007.

  2. Effectiveness of switching to the rivastigmine transdermal patch from oral cholinesterase inhibitors: a naturalistic prospective study in Alzheimer's disease.

    PubMed

    Cagnin, Annachiara; Cester, Alberto; Costa, Bruno; Ermani, Mario; Gabelli, Carlo; Gambina, Giuseppe

    2015-03-01

    Oral donepezil and rivastigmine are two commonly used cholinesterase inhibitors (ChEIs) used in Alzheimer's disease (AD). The rivastigmine transdermal patch formulation has high tolerability profile, allowing patients to achieve optimal therapeutic doses and providing potential advantages over oral ChEIs. This is a 6-month, multicentre, observational efficacy and tolerability study of switching from oral ChEIs to rivastigmine patch in AD patients who failed to show benefit from previous treatment. The reasons of the switch were: (1) lack/loss of benefit from previous oral ChEI treatment; (2) tolerability problems. The primary outcome was cognitive changes measured with the mini-mental state examination (MMSE) test. Secondary outcomes were modifications of functional independence and behavioral disturbances and occurrence of adverse events (AEs) after switching. 174 patients, over 180 patients screened, entered the study (lack/loss of efficacy: 57 %, tolerability problems: 33 %, both reasons: 10 %). 6 months after switching 56 % of patients stabilized or increased the MMSE score respect to baseline. The only predictor of this outcome was the response at 3 months. In the group with lack/loss of response to oral ChEI, the decline of the MMSE score changed from -3.4 ± 2.5 points in the 6 months before switching to -0.5 ± 3.2 in the 6 months after the switch (p < 0.001). There were no significant changes in the IADL or NPI scores. Drug discontinuation rate was 20 %, due to AEs (18 %) and lack of compliance (2 %). Switching from an unsuccessful oral ChEI therapy to rivastigmine patch is effective and safe in more than half of the switched patients after a 6-month period.

  3. Cross-reactions among hair dye allergens.

    PubMed

    Basketter, David A; English, John

    2009-01-01

    p-Phenylenediamine (PPD) is an important hair dye allergen, but there remains a reasonable suspicion that other hair dye chemicals may also be responsible for a proportion of the clinical burden of hair dye allergy. To assess to what extent presently assessed additional patch test agents contribute to the diagnosis of non-PPD hair dye allergy. A retrospective analysis was conducted of patch test results with hair dye allergens, focusing on the extent to which patients who were positive for allergic reactions to other hair dye allergens also had a concomitant positive reaction to PPD. For the hair dye allergens other than p-toluenediamine (PTD), reactions in the absence of a concomitant positive reaction to PPD were very rare. Positive reactors to PTD were also positive for reactions to PPD in 5 of every 6 cases. Pyrogallol positives often occurred in the absence of a PPD positive, but were never judged to be of clinical relevance. Hair dye chemicals other than PPD may be of importance, but the presently tested materials, with the possible exception of PTD, are normally positive only when a PPD-positive reaction is also present, suggesting that their use in patch testing in hair dye allergy is likely to be of limited value.

  4. [Hapten selection for patch tests in the diagnosis of allergic contact dermatitis: epidemiologic data].

    PubMed

    Romano, C; Carosso, A; Bosio, D; Chiesa, A; Gullino, A; Turrini, A

    2003-01-01

    Aim of the study was to verify the reliability in clinical practice of patch testing with "standard" series and additional series of haptens for the diagnosis of occupational and non-occupational allergic contact dermatitis, evaluating positive reactions and relating those reactions to professional categories. A total of 392 out of 937 patients (41.8%) showed at least one positive reaction to "standard" series testing; the hapten most frequently noted as the cause of positive reaction was nickel sulphate. Professional categories that showed positive reactions to "standard" series most frequently were clerks, hairdressers and hospital auxiliary workers. Among 897 patients tested with nonstandard allergens, only 124 (13.8%) elicited at least one positive reaction, ammonium persulphate being the most frequently positive hapten. A dominant percentage of positive results was seen in hairdressers and cleaning personnel. No positive reactions were observed in a large number of haptens, tested more than 200 times. Haptens of "standard series" elicited a higher number of positive reaction than the additional series, even though there was a high specificity of few additional series haptens in some professional categories. Data suggest some caution in systematically testing additional series, despite a higher accuracy and diagnostic efficacy in some job categories.

  5. Ulcerative colitis patients with an inflammatory response upon mesalazine cannot be desensitized: a randomized study.

    PubMed

    Buurman, Dorien J; De Monchy, Jan G R; Schellekens, Reinout C A; van der Waaij, Laurens A; Kleibeuker, Jan H; Dijkstra, Gerard

    2015-04-01

    Mesalazine is a key drug in the treatment of ulcerative colitis (UC). Intolerance to mesalazine has been described, including fever and gastrointestinal symptoms. Several case reports reported successful desensitization of patients with mesalazine intolerance. The aim was to assess the number of UC patients who are persistently intolerant to mesalazine after single-blinded rechallenge and to test the effectiveness of a rapid desensitization protocol in UC patients demonstrated mesalazine intolerance. This is a prospective, single-blind randomized study in UC patients who discontinued mesalazine because of intolerance. Patients with severe reactions were excluded. Eligible patients underwent a skin patch test with mesalazine followed by a single-blinded randomized crossover rechallenge with 500 mg mesalazine or placebo. Patients with symptoms upon rechallenge were admitted to the hospital for 3 days oral desensitization. Nine of the 37 identified UC patients who discontinued mesalazine because of intolerance were included. All nine patients had negative patch tests, seven patients had symptoms (fever, nausea, vomiting and diarrhea) within 2 h upon rechallenge. Four of these seven patients participated in the desensitization protocol and in none a successful desensitization could be performed. All four had an inflammatory intolerance reaction with rise in C-reactive protein. There were no elevations in serum tryptase or urinary-methylhistamine levels observed and no signs of immediate type allergic reactions, like urticaria, bronchial obstruction or anaphylaxis. We recommend not to rechallenge UC patients with an inflammatory response upon mesalazine and these patients will not benefit from a rapid desensitization protocol.

  6. Air-borne contact dermatitis caused exclusively by xanthium strumarium.

    PubMed

    Pasricha, J S; Verma, K K; D'Souza, P

    1995-01-01

    Most cases having air-borne contact dermatitis (ABCD) in India are considered to be caused by Parthenium hysterophorus. In some cases however, other plants have also been noticed to give positive patch test reactions. We are reporting two cases presenting as ABCD who showed positive patch tests with Xanthium strumarium while the patch tests with Parthenium hysterophorus were negative. It is therefore necessary to realise that every case of ABCD is not caused by Parthenium, and patch testing with Parthenium alone can lead to serious mistakes.

  7. [Continued Use of Rotigotine Transdermal Patches for Parkinson Disease].

    PubMed

    Yasutaka, Yuki; Fujioka, Shinsuke; Shibaguchi, Hirotomo; Imakyure, Osamu; Washiyama, Atsushi; Tsuboi, Yoshio; Futagami, Koujiro

    2016-06-01

    Transdermal patches containing rotigotine, a dopamine agonist (DA) for treatment of Parkinson disease, continuously exert stable effects when applied once daily. Therefore, they are expected to reduce the patient burdens due to complications such as wearing-off and dysphagia. However, dosing is occasionally reduced or discontinued after application because of several reasons such as skin reactions or unsatisfactory efficacy. To identify the risk factors involved in the reduced or discontinued use of rotigotine patches, a retrospective study was conducted with reference to the medical records of patients with Parkinson disease who received rotigotine patches in our hospital. 85 patients were involved in this study. Dosing of rotigotine was reduced or discontinued in 53 patients during the study period. The factors associated with charges in treatment included combination therapy with clonazepam and oral administration of another DA before the application of rotigotine. The reduction or discontinuation rate of rotigotine patches in patients who reduced the equivalent dose of DA on the introduction of rotigotine patches was 94.7%, showing a significantly higher rate compared with 61.3% in the increased dose group. To improve adherence to rotigotine patch therapy, physicians need to carefully consider concomitant drugs and total dose of DAs. (Received December 7, 2015; Accepted February 22, 2016; Published June 1, 2016).

  8. Pediatric Baseline Patch Test Series: Initial Findings of the Pediatric Contact Dermatitis Workgroup.

    PubMed

    Yu, JiaDe; Atwater, Amber Reck; Brod, Bruce; Chen, Jennifer K; Chisolm, Sarah S; Cohen, David E; de la Feld, Salma; Gaspari, Anthony A; Martin, Kari Lyn; Montanez-Wiscovich, Marjorie; Sheehan, Michael; Silverberg, Nanette; Lugo-Somolinos, Aida; Thakur, Binod K; Watsky, Kalman; Jacob, Sharon E

    2018-06-21

    Allergic contact dermatitis is a challenging diagnostic problem in children. Although epicutaneous patch testing is the diagnostic standard for confirmation of contact sensitization, it is less used in children by dermatologists treating children, pediatric dermatologists, and pediatricians, when compared with adult practitioners. The aim of the study was to create and evaluate standardization of a pediatric patch test series for children older than 6 years. We surveyed dermatologists and allergists conducting epicutaneous patch testing in children attending the 2017 American Contact Dermatitis Society meeting held in Washington, DC. This was followed by discussion of collected data and consensus review by a pediatric contact dermatitis working group at the conference. A baseline pediatric patch test panel was established through working group consensus.

  9. Effect of rivastigmine or memantine add-on therapy is affected by butyrylcholinesterase genotype in patients with probable Alzheimer's disease.

    PubMed

    Han, Hyun Jeong; Kwon, Jay C; Kim, Jung Eun; Kim, Shin Gyeom; Park, Jong-Moo; Park, Kyung Won; Park, Key Chung; Park, Kee Hyung; Moon, So Young; Seo, Sang Won; Choi, Seong Hye; Cho, Soo-Jin

    2015-01-01

    The K variant of butyrylcholinesterase (BCHE-K) exhibits a reduced acetylcholine-hydrolyzing capacity; so the clinical response to rivastigmine may differ in Alzheimer's disease (AD) patients with the BCHE-K gene. To investigate the clinical response to rivastigmine transdermal patch monotherapy or memantine plus rivastigmine transdermal patch therapy in AD patients based on the BCHE-K gene. A total of 146 probable AD patients consented to genetic testing for butyrylcholinesterase and underwent the final efficacy evaluations. Responders were defined as patients with an equal or better score on the Alzheimer's Disease Assessment Scale-cognitive subscale (ADAS-cog) at 16 weeks compared to their baseline score. BCHE-K carriers showed a lower responder rate on the ADAS-cog than non-carriers (38.2 vs. 61.7%, p = 0.02), and this trend was evident in AD patients with apolipoprotein E ε 4 (35 vs. 60.7%, p = 0.001). The presence of the BCHE-K allele predicted a worse response on the ADAS-cog (odds ratio 0.35, 95% confidence interval 0.14-0.87), after adjusting for demographic and baseline cognitive and functional variables. The BCHE-K genotype may be related to a poor cognitive response to rivastigmine patch or memantine add-on therapy, especially in the presence of apolipoprotein E ε 4.

  10. Patient adherence to transdermal rivastigmine after switching from oral donepezil: a retrospective claims database study.

    PubMed

    Tian, Haijun; Abouzaid, Safiya; Chen, Wei; Kahler, Kristijan H; Kim, Edward

    2013-01-01

    To examine patient adherence before and after switching from donepezil to the rivastigmine patch. This retrospective cohort study used the MarketScan Commercial and Medicare data sets (2004 to 2009). Patients with a diagnosis of Alzheimer disease who were new donepezil users and were subsequently switched to the rivastigmine patch were included. The proportion of days covered (PDC) and PDC difference between donepezil and the rivastigmine patch were calculated from the time of initiation to the switch, capped at 1 year after the first respective claim. PDC was calculated as the number of days with drugs available divided by the number of days in the respective follow-up periods. The sample included 772 patients (mean age 77 y; 58% female). The mean time between switching from donepezil to the rivastigmine patch was 579 (SD=317.3) days. The mean PDC for the rivastigmine patch was highest among patients who switched within 3 months (80.4% vs. 90.7%; P=0.04) and within 7 to 9 months (61.3% vs. 71.0%; P=0.05) of initiating donepezil. When adherence was analyzed in increments of 1 year, patients who switched to the rivastigmine patch within the first year of treatment had significantly greater adherence to rivastigmine compared with those who were on donepezil (PDC 69.3% vs. 60.6%; P=0.0004). Switching from donepezil to the rivastigmine patch seems to be associated with increased adherence, especially in patients who switched within the first year of initiating donepezil.

  11. Comparison of diagnostic value using a small, single channel, P-wave centric sternal ECG monitoring patch with a standard 3-lead Holter system over 24 hours.

    PubMed

    Smith, Warren M; Riddell, Fiona; Madon, Morag; Gleva, Marye J

    2017-03-01

    To compare simultaneous recordings from an external patch system specifically designed to ensure better P-wave recordings and standard Holter monitor to determine diagnostic efficacy. Holter monitors are a mainstay of clinical practice, but are cumbersome to access and wear and P-wave signal quality is frequently inadequate. This study compared the diagnostic efficacy of the P-wave centric electrocardiogram (ECG) patch (Carnation Ambulatory Monitor) to standard 3-channel (leads V1, II, and V5) Holter monitor (Northeast Monitoring, Maynard, MA). Patients were referred to a hospital Holter clinic for standard clinical indications. Each patient wore both devices simultaneously and served as their own control. Holter and Patch reports were read in a blinded fashion by experienced electrophysiologists unaware of the findings in the other corresponding ECG recording. All patients, technicians, and physicians completed a questionnaire on comfort and ease of use, and potential complications. In all 50 patients, the P-wave centric patch recording system identified rhythms in 23 patients (46%) that altered management, compared to 6 Holter patients (12%), P<.001. The patch ECG intervals PR, QRS and QT correlated well with the Holter ECG intervals having correlation coefficients of 0.93, 0.86, and 0.94, respectively. Finally, 48 patients (96%) preferred wearing the patch monitor. A single-channel ambulatory patch ECG monitor, designed specifically to ensure that the P-wave component of the ECG be visible, resulted in a significantly improved rhythm diagnosis and avoided inaccurate diagnoses made by the standard 3-channel Holter monitor. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Comparison of reactivity to a metallic disc and 2% aluminium salt in 366 children, and reproducibility over time for 241 young adults with childhood vaccine-related aluminium contact allergy.

    PubMed

    Gente Lidholm, Anette; Inerot, Annica; Gillstedt, Martin; Bergfors, Elisabet; Trollfors, Birger

    2018-07-01

    An aluminium hydroxide-adsorbed pertussis toxoid vaccine was studied in 76 000 children in the 1990s in Gothenburg, Sweden. Long-lasting itchy subcutaneous nodules at the vaccination site were seen in 745 participants. Of 495 children with itchy nodules who were patch tested for aluminium allergy, 377 were positive. In 2007-2008, 241 of the positive children were retested. Only in one third were earlier positive results reproduced. To further describe patch test reactions to different aluminium compounds in children with vaccine-induced aluminium allergy. Positive patch test results for metallic aluminium (empty Finn Chamber) and aluminium chloride hexahydrate 2% petrolatum (pet.) were analysed in 366 children with vaccine-induced persistent itching nodules tested in 1998-2002. Of those, 241 were tested a second time (2007-2008), and the patch test results of the two aluminium preparations were analysed. Patch testing with aluminium chloride hexahydrate 2% pet. is a more sensitive way to diagnose aluminium contact allergy than patch testing with metallic aluminium. A general decrease in the strength of reactions to both aluminium preparations in 241 children tested twice was observed. Aluminium contact allergy can be diagnosed by patch testing without using metallic aluminium. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Proposal of a skin tests based approach for the prevention of recurrent hypersensitivity reactions to iodinated contrast media.

    PubMed

    Della-Torre, E; Berti, A; Yacoub, M R; Guglielmi, B; Tombetti, E; Sabbadini, M G; Voltolini, S; Colombo, G

    2015-05-01

    The purpose of the present work is to evaluate the efficacy of an approach that combines clinical history, skin tests results, and premedication, in preventing recurrent hypersensitivity reactions to iodinated contrast media (ICM). Skin Prick tests, Intradermal tests, and Patch tests were performed in 36 patients with a previous reaction to ICM. All patients underwent a second contrast enhanced radiological procedure with an alternative ICM selected on the basis of the proposed approach. After alternative ICM re-injection, only one patient presented a mild NIR. The proposed algorithm, validated in clinical settings where repeated radiological exams are needed, offers a safe and practical approach for protecting patients from recurrent hypersensitivity reactions to ICM.

  14. Case Series: Keratolimbal Allograft as a Patch Graft for Glaucoma Drainage Devices.

    PubMed

    Ahmed, Sarah F; Schmutz, Mason; Mosaed, Sameh

    2017-09-01

    Tube exposure remains one of the most common complications after glaucoma drainage device (GDD) implantation, despite various types of patch grafts available today. We present a 4 patient case series following the effectivity of the keratolimbal allograft (KLAL) as a patch graft for cases of tube exposure. Given its inherent population of stem cells, our hypothesis was that this highly replicative, biological tissue would provide an adequate means of glaucoma tube coverage. The subset of patients chosen for the KLAL patch graft all had a history of abnormally scarred conjunctiva or thin sclera. The aim of utilizing the KLAL patch with its associated donor conjunctival and scleral ring was also to provide additional reinforcement and adequate tube coverage in the setting of compromised native tissue. Four patients comprised of 2 males and 2 females with a minimum postoperative period of 12 months. All GDDs were initially implanted with a limbal-based incision using either Ahmed glaucoma valve or Baerveldt drainage implant. Three of the 4 patients received the KLAL patch graft after tube exposure with scleral patch graft and 1 patient received KLAL as the primary graft during initial tube placement. Two of the 4 eyes experienced tube re-exposure postoperatively at 2 and 3 months, respectively. Both of these cases had a history of prior tube exposure after scleral patch graft and both were tubes placed in the pars plana. Interestingly, the patients with failed grafts were younger with a history of more ocular surgeries as compared with the patients with graft viable eyes. Through our case series, we found that the KLAL utilized as a patch graft over GDD tubes has the potential for favorable outcomes in certain subtypes of eyes. Although further large scale investigation will be necessary to better define the risk factors associated with graft failure, proving the graft's viability is a crucial first step.

  15. Esophageal motility and 24-h pH profiles of patients with heterotopic gastric mucosa in the cervical esophagus.

    PubMed

    Korkut, Esin; Bektaş, Mehmet; Alkan, Murat; Ustün, Yusuf; Meco, Cem; Ozden, Ali; Soykan, Irfan

    2010-02-01

    Heterotopic gastric mucosa occurs as a flat island of red mucosa in the proximal third of the esophagus where it gives rise to the cervical inlet patch. The aims of this study were to investigate the esophageal motility pattern and 24-h pH profiles of patients with cervical inlet patch. Thirty patients (16 women, mean age: 44.9 years, range: 23-72) diagnosed as having heterotopic gastric mucosa in the cervical esophagus with upper gastrointestinal symptoms had undergone esophageal motility testing and 24-h pH monitorisation with a double-channel pH probe. Manometric investigation was abnormal in 7 patients (non-specific esophageal motor disorder in 4 patients, esophageal hypomotility in 1 patient, and hypotensive LES in 2 patients). Pathological acid reflux (pH<4) was found in 9 (30%) of 30 heterotopic gastric mucosa patients during pH monitorisation from the distal probe. Pathological acid reflux in the proximal esophagus (percentage of total time of pH<4) was seen in four of these nine patients. Only four of the 30 patients (13.3%) presented with "acid independent episodes" during the 24-h esophageal pH monitorisation. Manometric investigation and 24-h pH monitorisation revealed that some of the patients with HGM have signs of esophageal motor dysfunction and "acid independent episodes" from the patches. These abnormalities may be responsible for some of the symptoms of HGM patients. Copyright 2009 European Federation of Internal Medicine. Published by Elsevier B.V. All rights reserved.

  16. Application of a buprenorphine transdermal patch for the perioperative analgesia in patients who underwent simple lumbar discectomy

    PubMed Central

    Tang, Jian; Fan, Jin; Yao, Yilun; Cai, Weihua; Yin, Guoyong; Zhou, Wei

    2017-01-01

    Abstract This study aimed to investigate the perioperative analgesic effect of a buprenorphine transdermal patch in patients who underwent simple lumbar discectomy. In total, 96 patients were randomly divided into parecoxib intravenous injection (Group A), oral celecoxib (Group B), and buprenorphine transdermal patch groups (Group C). The pain status, degree of satisfaction, adverse effects, and condition in which the patient received tramadol hydrochloride for uncontrolled pain were recorded on the night before surgery, postoperative day 1, postoperative day 3, and postoperative day 5. The degree of patient satisfaction in Group C was higher than that in Groups A and B, with minimal adverse effects. The buprenorphine transdermal patch had a better perioperative analgesic effect in patients who underwent simple lumbar discectomy. PMID:28514299

  17. Portable acuity screening for any school: validation of patched HOTV with amblyopic patients and Bangerter normals.

    PubMed

    Tsao Wu, Maya; Armitage, M Diane; Trujillo, Claire; Trujillo, Anna; Arnold, Laura E; Tsao Wu, Lauren; Arnold, Robert W

    2017-12-04

    We needed to validate and calibrate our portable acuity screening tools so amblyopia could be detected quickly and effectively at school entry. Spiral-bound flip cards and download pdf surround HOTV acuity test box with critical lines were combined with a matching card. Amblyopic patients performed critical line, then threshold acuity which was then compared to patched E-ETDRS acuity. 5 normal subjects wore Bangerter foil goggles to simulate blur for comparative validation. The 31 treated amblyopic eyes showed: logMAR HOTV = 0.97(logMAR E-ETDRS)-0.04 r2 = 0.88. All but two (6%) fell less than 2 lines difference. The five showed logMAR HOTV = 1.09 ((logMAR E-ETDRS) + .15 r2 = 0.63. The critical-line, test box was 98% efficient at screening within one line of 20/40. These tools reliably detected acuity in treated amblyopic patients and Bangerter blurred normal subjects. These free and affordable tools provide sensitive screening for amblyopia in children from public, private and home schools. Changing "pass" criteria to 4 out of 5 would improve sensitivity with somewhat slower testing for all students.

  18. The frequency of fragrance allergy in a patch-test population over a 17-year period.

    PubMed

    Buckley, D A; Wakelin, S H; Seed, P T; Holloway, D; Rycroft, R J; White, I R; McFadden, J P

    2000-02-01

    Fragrances are widely encountered in our daily environment and are known to be a common cause of allergic contact dermatitis. We have reviewed our patch test data from 1980 to 1996 to establish whether the pattern of fragrance allergy has changed with time. During this period, 25,545 patients (10,450 male, 15,005 female) were patch tested with the European standard series. The mean annual frequency of positive reactions to the fragrance mix was 8.5% in females (range 6.1-10.9) and 6.7% in males (range 5.1-12.9). Females were 1.3 times more likely to be allergic to fragrance (P < 0.001, 95% confidence interval, CI 1.17-1.41). Males with fragrance allergy were older than females by 5.6 years (mean age 48.2 vs. 42.6 years; P < 0.001, 95% CI 3.9-7.3). The incidence of a concomitant positive patch test to balsam of Peru in fragrance-sensitive patients showed wide variation, suggesting that it is not a reliable marker of fragrance allergy. There was a positive correlation between the isomers isoeugenol and eugenol. Oak moss remained the most common overall allergen throughout the study, positive in 38.3% of females and 35.6% of males who were tested to the constituents of the fragrance mix. During the period of the study the incidence of positive tests to oak moss increased by 5% yearly (P = 0.001, 95% CI 2.2-8.7). The frequency of allergic reactions to eugenol and geraniol remained relatively constant. Isoeugenol and alpha-amyl cinnamic aldehyde sensitivity increased and hydroxycitronellal showed a slow decline. There was a striking reduction in the frequency of sensitivity to cinnamic aldehyde (by 18% yearly; P < 0.001, 95% CI 14.3-21.0) and cinnamic alcohol (by 9% yearly; P < 0.001, 95% CI 5.2-12.9); these are now uncommon fragrance allergens. These data show temporal trends which may reflect the frequency of population exposure to individual fragrances.

  19. Rivastigmine Patch in Chinese Patients with Probable Alzheimer's disease: A 24-week, Randomized, Double-Blind Parallel-Group Study Comparing Rivastigmine Patch (9.5 mg/24 h) with Capsule (6 mg Twice Daily).

    PubMed

    Zhang, Zhen-Xin; Hong, Zhen; Wang, Yan-Ping; He, Li; Wang, Ning; Zhao, Zhong-Xin; Zhao, Gang; Shang, Lan; Weisskopf, Marianne; Callegari, Francesca; Strohmaier, Christine

    2016-06-01

    To compare the once-daily rivastigmine patch 9.5 mg/24 h (10 cm(2) ) versus twice-daily capsule (12 mg/day) in Chinese patients with probable Alzheimer's disease (AD) (mini-mental state examination [MMSE] scores of 10-20). The primary objective was to demonstrate the noninferiority of patch to capsule in Alzheimer's Disease Assessment Scale-Cognitive subscale (ADAS-Cog) change from baseline to 24 week. Secondary endpoints included cognition (MMSE), overall clinical response (Alzheimer's Disease Cooperative Study-Clinical Global Impression of Change [ADCS-CGIC]), activities of daily living (Alzheimer's Disease Cooperative Study-Activities of Daily Living [ADCS-ADL]), behavior (Neuropsychiatric Inventory [NPI-12]), and safety. Similar cognitive improvement was observed in both patch (n = 248) and capsule (n = 253) groups. Statistical noninferiority for ADAS-Cog was not established (least-square means difference, 0.1; 95% confidence interval, -1.2; 1.5). Considering all efficacy parameters into account, both treatments showed similar performance at Week 24. Treatment-related adverse events (AEs) were lower for patch (39.7%) compared with capsule (49.8%). Application site pruritus was reported in 10.9% of patients receiving patch; most cases were mild. Gastrointestinal AEs including nausea, vomiting, and diarrhea occurred less frequently in the patch group (15.8% vs. 28.7%). Rivastigmine patch 9.5 mg/24 h is effective and well tolerated in Chinese patients with probable AD. © 2016 John Wiley & Sons Ltd.

  20. T cell lymphomatoid contact dermatitis: a challenging case and review of the literature.

    PubMed

    Knackstedt, Thomas J; Zug, Kathryn A

    2015-02-01

    Lymphomatoid contact dermatitis is a pseudolymphoma with clinical and histological features of allergic contact dermatitis and cutaneous T cell lymphoma. Incorrect diagnosis may lead to unnecessary testing, unnecessary treatment, or patient harm. The objective of this study is to present a case to demonstrate the diagnostic challenge and overlap between allergic contact dermatitis and cutaneous T cell lymphoma in a patient with lymphomatoid contact dermatitis caused by methylchoroisothiazolinone/methylisothiazolinone and paraben mix, and to review the existing literature in order to summarize the demographics, clinical features, allergens and treatments reported for lymphomatoid contact dermatitis. A search of major scientific databases was conducted for English-language articles reporting cases of lymphomatoid contact dermatitis or additional synonymous search headings. Nineteen articles with a total of 23 patients were analysed. Lymphomatoid contact dermatitis was more common in men, with an average age of 58.5 years. Fourteen unique allergens were identified and confirmed by patch testing. However, no single test or study was diagnostic of lymphomatoid contact dermatitis. Allergen avoidance was the most useful management tool, but selected patients required topical or systemic immunosuppression. In conclusion, without specific diagnostic features, evaluation for lymphomatoid contact dermatitis should include a thorough history and examination, patch testing, and biopsy with immunohistochemistry and clonality studies. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Positive lymphocyte transformation test in a patient with allergic contact dermatitis of the scalp after short-term use of topical minoxidil solution.

    PubMed

    Hagemann, Tobias; Schlütter-Böhmer, Brigitte; Allam, Jean-Pierre; Bieber, Thomas; Novak, Natalija

    2005-07-01

    Topical 2,4-diamino-6-piperidinopyrimidine-3-oxide (minoxidil) solution has been widely used for the treatment of androgenetic alopecia for over 15 years now and the substance is currently approved for this indication in 2% and 5% formulation. Typical side effects of this topical treatment include irritative dermatitis going along with pruritus, erythema, scaling and dryness, which occur especially at the onset of the therapy. In some cases, allergic contact dermatitis or exacerbation of seborrheic dermatitis has been reported. While most of the patients with allergic contact dermatitis described in the literature showed a positive sensitization to the vehicle substance propylene glycol evaluated by patch testing, reactions to the active ingredient minoxidil are rare. Here, we report a case of allergic sensitization to minoxidil, which we evaluated and differentiated from an irritative reaction by a combination of patch testing and lymphocyte transformation test. The differentiation of allergic and irritative adverse effects and the identification of the causative allergen are of major relevance for the proceeding and adjustment of the therapy. Patients with sensitizations against propylene glycol are candidates for preparations with alternative solvents but can proceed treatment with minoxidil. In contrast, patients with allergies to the active ingredient itself are no longer candidates for treatment with minoxidil and should undergo alternative therapeutic options.

  2. Asthma, rhinitis, and dermatitis in workers exposed to reactive dyes.

    PubMed Central

    Nilsson, R; Nordlinder, R; Wass, U; Meding, B; Belin, L

    1993-01-01

    A survey was conducted at 15 textile plants with dyehouses in western Sweden. Employees with a history of work related rhinitis, asthma, or skin symptoms were offered a clinical and immunological investigation including skin prick tests, skin patch tests, and radioallergosorbent tests (RASTs) to detect specific allergy to reactive dyes. Among the 1142 employees, 162 were exposed to reactive dyes and 10 of these (6%) reported work related respiratory or nasal symptoms. An allergy to reactive dyes could be confirmed in five (3%, 95% confidence interval 1-7%). All but one had been exposed to reactive dyes for one year or less before the onset of symptoms. Positive RASTs could be detected in four of the five patients. All of the RAST positive patients were positive to remazol black B, but six out of eight additional remazol dyes also elicited positive results. RAST and RAST inhibition showed a cross reactivity between some of the dyes. Seven persons with work related dermatitis and three with urticaria or Quincke oedema were found. In one patient contact dermatitis to a monoazo dye was shown, but no positive patch test reactions to reactive dyes. IgE-mediated allergy to reactive dyes seems to be an important cause of respiratory and nasal symptoms among dyehouse employees exposed to dust from reactive dyes. PMID:8431393

  3. Long-term outcome of large artificial patch aortic repair for diffuse stenosis in Williams syndrome.

    PubMed

    Sughimoto, Koichi; Takahara, Yoshiharu; Mogi, Kenji; Sakurai, Manabu; Aoki, Chikashi

    2010-10-01

    There have been only a few reports concerning the long-term results of a surgical procedure using a large artificial patch for patients with Williams syndrome. Twelve years have passed since a patient with William's syndrome underwent a surgery with a patch angioplasty for the diffuse supravalvular aortic stenosis and deformities of the neck branch arteries. The patient had a well-balanced aortic growth without stenotic or aneurysmal changes, which was confirmed during the time of the second surgery when replacing the mitral valve. This technique of using a large patch has proven to be safe for Williams syndrome patients with diffuse supravalvular aortic stenosis in the long term.

  4. A fabric wrist patch sensor for continuous and comprehensive monitoring of the cardiovascular system.

    PubMed

    Kwonjoon Lee; Kiseok Song; Taehwan Roh; Hoi-Jun Yoo

    2016-08-01

    The wrist patch-type ECG/APW sensor system is proposed for continuous and comprehensive monitoring of the patient's cardiovascular system. The wrist patch-type ECG/APW sensor system is consists of ECG/APW sensor, ECG/APW electrodes, and base station for real-time monitoring of the patient's status. The ECG/APW sensor and electrodes are composed of wrist patch, bandage-type ECG electrode and fabric APW electrode, respectively so that the patient's cardiovascular system can be continuously monitored in daily life with free hand-movement. Since the proposed wrist patchtype ECG/APW sensor simultaneously measures ECG/APW, the cardiac indicators, such as HR and PAT, can be extracted for comprehensive and accurate monitoring of the patient's cardiovascular system. The proposed wrist patch-type ECG/APW sensor system is successfully verified using the commercial PPG sensor (RP520) and demonstrated with the customized Android application on the smart phone.

  5. MS lesion segmentation using a multi-channel patch-based approach with spatial consistency

    NASA Astrophysics Data System (ADS)

    Mechrez, Roey; Goldberger, Jacob; Greenspan, Hayit

    2015-03-01

    This paper presents an automatic method for segmentation of Multiple Sclerosis (MS) in Magnetic Resonance Images (MRI) of the brain. The approach is based on similarities between multi-channel patches (T1, T2 and FLAIR). An MS lesion patch database is built using training images for which the label maps are known. For each patch in the testing image, k similar patches are retrieved from the database. The matching labels for these k patches are then combined to produce an initial segmentation map for the test case. Finally a novel iterative patch-based label refinement process based on the initial segmentation map is performed to ensure spatial consistency of the detected lesions. A leave-one-out evaluation is done for each testing image in the MS lesion segmentation challenge of MICCAI 2008. Results are shown to compete with the state-of-the-art methods on the MICCAI 2008 challenge.

  6. Diagnostic performance of the atopy patch test with inhalant allergens.

    PubMed

    Fuiano, N; Diddi, G; Delvecchio, M; Incorvaia, C

    2015-01-01

    This study evaluated the diagnostic performance of the atopy patch test (APT) compared with skin prick testing (SPT) and in vitro IgE measurement in a large group of patients with atopic dermatitis (AD) with or without respiratory symptoms (RS). The study included 521 patients (292 males, 229 females; age, 0.5-18 years; median age, 6 years) with AD and RS with different clinical presentations: current AD, 47 patients (Group A); current AD and RS, 72 patients (Group B), past AD and RS, 69 patients (Group C); and RS only, 280 patients (Group D). Fifty-three healthy individuals served as controls. All participants underwent the APT, SPT, and CAP/RAST with the most common inhalant allergens. The presence of a control group allowed calculation of specificity and positive and negative predictive values. A significant difference was found for a positive APT versus both SPT and CAP/RAST (P < .0001) but not for SPT versus CAP/RAST. The differences for APT were significant in all group comparisons except group B vs C and group C vs D. In the control group, the APT was positive in 2% of cases (specificity of 96.2%), SPT was positive in 6% of cases (specificity of 88.4%), and CAP/RAST was positive in 4% of cases (specificity of 92.5%). In young patients sensitized to inhalant allergens with AD in addition to RS, the APT has a superior diagnostic performance to SPT and in vitro IgE measurement.

  7. Outbreak of contact sensitization to methylisothiazolinone: an analysis of French data from the REVIDAL-GERDA network.

    PubMed

    Hosteing, Stéphanie; Meyer, Nicolas; Waton, Julie; Barbaud, Annick; Bourrain, Jean-Luc; Raison-Peyron, Nadia; Felix, Brigitte; Milpied-Homsi, Brigitte; Ferrier Le Bouedec, Marie-Christine; Castelain, Michel; Vital-Durand, Dominique; Debons, Michèle; Collet, Evelyne; Avenel-Audran, Martine; Mathelier-Fusade, Pascale; Vermeulen, Christophe; Assier, Haudrey; Gener, Gwendoline; Lartigau-Sezary, Isabelle; Catelain-Lamy, Amandine; Giordano-Labadie, Françoise

    2014-05-01

    The preservative methylisothiazolinone (MI) is used in combination with methylchloroisothiazolinone (MCI), but the MCI/MI mixture has been identified as highly allergenic. MI is considered to be less allergenic, and since the mid-2000s has been widely used alone, but is now clearly identified as a contact allergen. The French Vigilance Network for Dermatology and Allergy of the Study and Research Group on Contact Dermatitis (REVIDAL-GERDA) added MI to its baseline patch testing series in 2010. To evaluate the change in the proportion of MI-positive tests in France between 2010 and 2012. We conducted a nationwide, multicentre, retrospective study of all MI-tested patients between 2010 and 2012. Sixteen centres participated in the study (7874 patients were tested). Patch tests were performed mainly at a concentration of MI 200 ppm aq. We observed a significant increase in the proportion of MI-positive tests in 2012 and 2011 as compared with 2010 (5.6%, 3.3%, and 1.5%, respectively; p < 0.001). We report a significant increase in the number of MI-positive tests. MI is confirmed to be a rapidly emerging allergen, as also observed in other European countries. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Capsaicin 8% patch treatment for amputation stump and phantom limb pain: a clinical and functional MRI study

    PubMed Central

    Privitera, Rosario; Birch, Rolfe; Sinisi, Marco; Mihaylov, Iordan R; Leech, Robert; Anand, Praveen

    2017-01-01

    Purpose The aim of this study was to measure the efficacy of a single 60 min application of capsaicin 8% patch in reducing chronic amputation stump and phantom limb pain, associated hypersensitivity with quantitative sensory testing, and changes in brain cortical maps using functional MRI (fMRI) scans. Methods A capsaicin 8% patch (Qutenza) treatment study was conducted on 14 patients with single limb amputation, who reported pain intensity on the Numerical Pain Rating Scale ≥4/10 for chronic stump or phantom limb pain. Pain assessments, quantitative sensory testing, and fMRI (for the lip pursing task) were performed at baseline and 4 weeks after application of capsaicin 8% patch to the amputation stump. The shift into the hand representation area of the cerebral cortex with the lip pursing task has been correlated with phantom limb pain intensity in previous studies, and was the fMRI clinical model for cortical plasticity used in this study. Results The mean reduction in spontaneous amputation stump pain, phantom limb pain, and evoked stump pain were −1.007 (p=0.028), −1.414 (p=0.018), and −2.029 (p=0.007), respectively. The areas of brush allodynia and pinprick hypersensitivity in the amputation stump showed marked decreases: −165 cm2, −80% (p=0.001) and −132 cm2, −72% (p=0.001), respectively. fMRI analyses provided objective evidence of the restoration of the brain map, that is, reversal of the shift into the hand representation of the cerebral cortex with the lip pursing task (p<0.05). Conclusion The results show that capsaicin 8% patch treatment leads to significant reduction in chronic pain and, particularly, in the area of stump hypersensitivity, which may enable patients to wear prostheses, thereby improving mobility and rehabilitation. Phantom limb pain (“central” pain) and associated brain plasticity may be modulated by peripheral inputs, as they can be ameliorated by the peripherally restricted effect of the capsaicin 8% patch. PMID:28761369

  9. Post-implantation erythema in 3 patients and a review of reticular telangiectatic erythema.

    PubMed

    Aneja, Savina; Taylor, James S; Billings, Steven D; Honari, Golara; Sood, Apra

    2011-05-01

    The appearance of erythematous, blanchable patches or plaques overlying an implant suggests possible reticular telangiectatic erythema (RTE). RTE is a benign reactive cutaneous manifestation that can present following the implantation of a cardiac pacemaker, defibrillator or intrathecal infusion pump in an otherwise asymptomatic, non-infectious patient. To demonstrate the variety in clinical presentation of patients presenting with RTE or similar patch test-negative post-implantation erythema. After institutional board approval had been obtained, patient information was obtained from electronic medical record files, which included surgical reports, pathology reports, and notes from outpatient encounters. We report post-implantation erythema following insertion of an elbow prosthesis, a knee prosthesis, and a spinal cord stimulator, which have not previously been cited as aetiologies of RTE. Owing to the delayed onset and variable recovery, RTE remains a diagnostic challenge. RTE should be included in the differential diagnosis of any patient presenting with erythema over the site of a previously implanted device. © 2011 John Wiley & Sons A/S.

  10. Generation of synthetic CT using multi-scale and dual-contrast patches for brain MRI-only external beam radiotherapy.

    PubMed

    Aouadi, Souha; Vasic, Ana; Paloor, Satheesh; Torfeh, Tarraf; McGarry, Maeve; Petric, Primoz; Riyas, Mohamed; Hammoud, Rabih; Al-Hammadi, Noora

    2017-10-01

    To create a synthetic CT (sCT) from conventional brain MRI using a patch-based method for MRI-only radiotherapy planning and verification. Conventional T1 and T2-weighted MRI and CT datasets from 13 patients who underwent brain radiotherapy were included in a retrospective study whereas 6 patients were tested prospectively. A new contribution to the Non-local Means Patch-Based Method (NMPBM) framework was done with the use of novel multi-scale and dual-contrast patches. Furthermore, the training dataset was improved by pre-selecting the closest database patients to the target patient for computation time/accuracy balance. sCT and derived DRRs were assessed visually and quantitatively. VMAT planning was performed on CT and sCT for hypothetical PTVs in homogeneous and heterogeneous regions. Dosimetric analysis was done by comparing Dose Volume Histogram (DVH) parameters of PTVs and organs at risk (OARs). Positional accuracy of MRI-only image-guided radiation therapy based on CBCT or kV images was evaluated. The retrospective (respectively prospective) evaluation of the proposed Multi-scale and Dual-contrast Patch-Based Method (MDPBM) gave a mean absolute error MAE=99.69±11.07HU (98.95±8.35HU), and a Dice in bones DI bone =83±0.03 (0.82±0.03). Good agreement with conventional planning techniques was obtained; the highest percentage of DVH metric deviations was 0.43% (0.53%) for PTVs and 0.59% (0.75%) for OARs. The accuracy of sCT/CBCT or DRR sCT /kV images registration parameters was <2mm and <2°. Improvements with MDPBM, compared to NMPBM, were significant. We presented a novel method for sCT generation from T1 and T2-weighted MRI potentially suitable for MRI-only external beam radiotherapy in brain sites. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  11. Report of a patient chewing fentanyl patches who was titrated onto methadone

    PubMed Central

    Dale, Eric; Ashby, Fleur; Seelam, Kalyan

    2009-01-01

    This case report discusses the clinical presentation and management of a patient presenting to substance misuse services reporting chewing fentanyl patches in addition to wearing them transdermally. The patient was successfully titrated onto methadone 30 mg. Only one previously reported case of an individual chewing fentanyl patches was found in the literature; no case reports were found where treatment involved titrating the patient onto methadone. The pharmacology and illicit use of fentanyl are also considered. PMID:22114625

  12. Evaluation of modifications of the traditional patch test in assessing the chemical irritation potential of feminine hygiene products.

    PubMed

    Farage, Miranda A; Meyer, Sandy; Walter, Dave

    2004-05-01

    The first main objective of the work presented in this paper was to investigate ways of optimizing the current arm patch test protocol by (1) increasing the sensitivity of the test in order to evaluate more effectively the products that are inherently non-irritating, and/or (2) reducing the costs of these types of studies by shortening the protocol. The second main objective was to use the results of these studies and the results of the parallel studies conducted using the behind-the-knee method to better understand the contribution of mechanical irritation to the skin effects produced by these types of products. In addition, we were interested in continuing the evaluation of sensory effects and their relationship to objective measures of irritation. Test materials were prepared from three, currently marketed feminine protection pads. Wet and dry samples were applied to the upper arm using the standard 24-h patch test. Applications were repeated daily for 4 consecutive days. The test sites were scored for irritation prior to the first patch application, and 30-60 min after removal of each patch. Some test sites were treated by tape stripping the skin prior to the initial patch application. In addition, in one experiment, panelists were asked to keep a daily diary describing any sensory skin effects they noticed at each test site. All protocol variations ([intact skin/dry samples], [compromised skin/dry samples], [intact skin/wet samples], and [compromised skin/wet samples]) gave similar results for the products tested. When compared to the behind-the-knee test method, the standard upper arm patch test gave consistently lower levels of irritation when the test sites were scored shortly after patch removal, even though the sample application was longer (24 vs. 6 h) in the standard patch test. The higher level of irritation in the behind-the-knee method was likely due to mechanical irritation. The sensory skin effects did not appear to be related to a particular test product or a particular protocol variation. However, the mean irritation scores at those sites where a sensory effect was reported were higher than the mean irritation scores at those sites were no sensory effects were reported. All four protocol variations of the standard upper arm patch test can be used to assess the inherent chemical irritant properties of feminine protection products. For these products, which are inherently non-irritating, tape stripping and/or applying wet samples does not increase the sensitivity of the patch test method. Differences in irritation potential were apparent after one to three 24-h applications. Therefore, the standard patch test protocol can be shortened to three applications without compromising our ability to detect differences in the chemical irritation produced by the test materials. The patch test can be used to evaluate effectively the inherent chemical irritation potential of these types of products. However, this method is not suitable for testing the mechanical irritation due to friction that occurs during product use. There is no relationship between specific test conditions, i.e., compromised skin and/or testing wet samples and reports of perceived sensory reactions. However, there seems to be a clear relationship between sensory reactions and objective irritation scores.

  13. Allergic contact dermatitis to epoxy resin in a hemodialysis cannula.

    PubMed

    Ng, P P; Leow, Y H; Ng, S K; Goh, C L

    1998-03-01

    A patient with chronic renal failure on hemodialysis presented with dermatitis, particularly over the arteriovenous fistulae sites on the forearm. Patch testing revealed a positive reaction to epoxy resin present in the glue that fixed the needle of the hemodialysis cannula.

  14. Is Decellularized Porcine Small Intestine Sub-mucosa Patch Suitable for Aortic Arch Repair?

    PubMed Central

    Corno, Antonio F.; Smith, Paul; Bezuska, Laurynas; Mimic, Branko

    2018-01-01

    Introduction: We reviewed our experience with decellularized porcine small intestine sub-mucosa (DPSIS) patch, recently introduced for congenital heart defects. Materials and Methods: Between 10/2011 and 04/2016 a DPSIS patch was used in 51 patients, median age 1.1 months (5 days to 14.5 years), for aortic arch reconstruction (45/51 = 88.2%) or aortic coarctation repair (6/51 = 11.8%). All medical records were retrospectively reviewed, with primary endpoints interventional procedure (balloon dilatation) or surgery (DPSIS patch replacement) due to patch-related complications. Results: In a median follow-up time of 1.5 ± 1.1 years (0.6–2.3years) in 13/51 patients (25.5%) a re-intervention, percutaneous interventional procedure (5/51 = 9.8%) or re-operation (8/51 = 15.7%) was required because of obstruction in the correspondence of the DPSIS patch used to enlarge the aortic arch/isthmus, with median max velocity flow at Doppler interrogation of 4.0 ± 0.51 m/s. Two patients required surgery after failed interventional cardiology. The mean interval between DPSIS patch implantation and re-intervention (percutaneous procedure or re-operation) was 6 months (1–17 months). While there were 3 hospital deaths (3/51 = 5.9%) not related to the patch implantation, no early or late mortality occurred for the subsequent procedure required for DPSIS patch interventional cardiology or surgery. The median max velocity flow at Doppler interrogation through the aortic arch/isthmus for the patients who did not require interventional procedure or surgery was 1.7 ± 0.57 m/s. Conclusions: High incidence of re-interventions with DPSIS patch for aortic arch and/or coarctation forced us to use alternative materials (homografts and decellularized gluteraldehyde preserved bovine pericardial matrix). PMID:29900163

  15. Generalized Peritonitis Requiring Re-operation After Leakage of Omental Patch Repair of Perforated Peptic Ulcer

    PubMed Central

    Maghsoudi, Hemmat; Ghaffari, Alireza

    2011-01-01

    Background/Aim: Peptic ulcer perforations are a common emergency, but available literature is silent on the exact definition, incidence, management, and complications of peritonitis due to omental patch leakage. Patients and Methods: Retrospective data were collected on 422 patients who underwent omental patch repair of perforated peptic ulcer between March 20, 1999 and March 20, 2006. The definitive diagnosis of perforated peptic ulcer and omental patch leakage was obtained at surgery. Results: Seventeen (4%) patients experienced generalized peritonitis due to omental patch leakage. Mean age was 60.6 years. Mortality rate was 29.4%, and the mean hospital stay was 23.6 days. Delay in surgical approach, shock on admission, and age were all significantly associated with increased mortality. Conclusions: Peritonitis due to omental patch leakage can result in significant morbidity and mortality. The most common causes of omental patch leakage and operative procedures were unknown and reinsertion of omentum, respectively. Factors such as shock on admission or delayed surgery, have significantly contributed to fatal outcomes and need careful attention. PMID:21372350

  16. Quantitative detection of glucose level based on radiofrequency patch biosensor combined with volume-fixed structures.

    PubMed

    Qiang, Tian; Wang, Cong; Kim, Nam-Young

    2017-12-15

    A concept for characterizing a radiofrequency (RF) patch biosensor combined with volume-fixed structures is presented for timely monitoring of an individual's glucose levels based on frequency variation. Two types of patch biosensors-separately integrated with a backside slot (0.53μL) and a front-side tank (0.70μL) structure-were developed to achieve precise and efficient detection while excluding the effects of interference due to the liquidity, shape, and thickness of the tested glucose sample. A glucose test analyte at different concentrations (50-600mg/dL) was dropped into the volume-fixed structures. It fully interacted with the RF patch electromagnetic field, effectively and sensitively changing the resonance frequency and magnitude of the reflection coefficient. Measurement results based on the resonance frequency showed high sensitivity up to 1.13MHz and 1.97MHz per mg/dL, and low detection limits of 26.54mg/dL and 15.22mg/dL, for the two types of patch biosensors, respectively, as well as a short response time of less than 1s. Excellent reusability of the proposed biosensors was verified through three sets of measurements for each individual glucose sample. Regression analysis revealed a good linear correlation between glucose concentrations and the resonance frequency shift. Moreover, to facilitate a multi-parameter-sensitive detection of glucose, the magnitude of the reflection coefficient was also tested, and it showed a good linear correlation with the glucose concentration. Thus, the proposed approach can be adopted for distinguishing glucose solution levels, and it is a potential candidate for early-stage detection of glucose levels in diabetes patients. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Factors Associated with Greater Adherence to and Satisfaction with Transdermal Rivastigmine in Patients with Alzheimer's Disease and Their Caregivers.

    PubMed

    Riepe, Matthias; Weinman, John; Osae-Larbi, Judith; Mulick Cassidy, Amy; Knox, Sean; Chaves, Ricardo; Müller, Beate

    2015-01-01

    Adherence to cholinesterase inhibitors is important in order to maximise treatment efficacy. This study aimed to investigate patient and caregiver factors associated with adherence to and satisfaction with transdermal rivastigmine treatment. Sociodemographic, clinical and psychosocial data were collected from 127 patients and their caregivers during the first follow-up visit after prescription. At the second follow-up, data were collected on 110 of the dyads. Adherence to and satisfaction with the treatment were assessed using the Medication Adherence Report Scale and an adapted version of the Alzheimer's Disease Caregiver Preference Questionnaire. 66.2% of the caregivers reported being adherent to, and 77.0% were satisfied with, the patch at the second follow-up. Factors predicting higher adherence at the second follow-up were caregivers' greater frequency of contact with patients, greater satisfaction with the information received about the patch, better tolerability of the patch and living at home with their caregivers. Greater concerns of the caregivers about the patch and the patients' belief in 'other' causes of their Alzheimer's disease predicted a lower adherence at the second follow-up. Assessing and addressing caregivers' concerns about transdermal rivastigmine, improving doctor-patient/caregiver communication to increase caregiver satisfaction with information about the patch as well as providing education and support around patients' beliefs and tolerability of the patch could improve adherence to transdermal rivastigmine. © 2015 S. Karger AG, Basel.

  18. Cusp repair in aortic valve reconstruction: does the technique affect stability?

    PubMed

    Aicher, Diana; Langer, Frank; Adam, Oliver; Tscholl, Dietmar; Lausberg, Henning; Schäfers, Hans-Joachim

    2007-12-01

    Cusp prolapse may be an isolated cause of aortic regurgitation or may exist in conjunction with dilatation of the proximal aorta. Prolapse can be corrected by central plication, triangular resection, or pericardial patch implantation. We retrospectively analyzed our results with these techniques. From October 1995 to December 2006, 604 patients (aged 3-86 years) underwent aortic valve repair. Cusp prolapse was found in 427 patients (246 tricuspid, 181 bicuspid). Prolapse was corrected by central plication (n = 275) or triangular resection (n = 80). A pericardial patch was implanted for pre-existing cusp defects or after excision of calcium (n = 72). One cusp was repaired in 198 patients; the remaining patients underwent repair of 2 (n = 189) or 3 cusps (n = 40). In 102 patients more than one technique was used, and the patients were allocated to the group of the assumedly more complex repair (central plication < triangular resection < pericardial patch plasty). Cumulative follow-up was 1238 patient-years (mean 35 +/- 27 months). Hospital mortality was 2.6% (11/427). Actuarial freedom from aortic regurgitation of grade II or more at 5 years was 92% (central plication), 90% (triangular resection), and 90% (pericardial patch plasty). Thirteen patients were reoperated on, with prolapse as the most common reason for failure (n = 7); 6 underwent re-repair. Freedom from reoperation at 5 years was 95% (central plication), 94% (triangular resection), and 94% (pericardial patch plasty). Freedom from valve replacement at 5 years was 97% (central plication), 99% (triangular resection), and 98% (pericardial patch plasty). In aortic valve repair, cusp prolapse can be treated reliably by central plication. In the presence of more complex disease, triangular resection or pericardial patch plasty may be used without compromising midterm durability.

  19. [Evaluation of the 2.5 mg fentanyl patch, applied using the half-side application procedure in patients with cancer pain].

    PubMed

    Kokubun, Hideya; Matoba, Motohiro; Okazaki, Miyoko; Hoka, Sumio; Yago, Kazuo

    2008-03-01

    Occasionally, pain control with the fentanyl patch may lead to overdose at an initial dose of 2.5 mg, as well as during dose increase from 2.5 to 5.0 mg. Respiratory depression and other adverse drug reactions associated with fentanyl overdose have been observed in several of our patients. We developed a procedure for applying one-half of the fentanyl patch formulations and evaluated the new mode of application by examining the fentanyl concentration in 32 patients with cancer-related pain who had been using the fentanyl patch for pain control. While some patients were treated with the full-sized 2.5-, 5.0-, or 7.5-mg formulations, others were treated with the half-sized 2.5-mg formulation. The fentanyl patch was equally divided by drawing a line on the side on which the product name and dose were written. Tegaderm was applied to the patient's skin, and after detaching from the protective liner, half of the patch was applied to overlap Tegaderm along the line and the other half applied directly to the skin. Blood samples were collected 48-72 h after patch application. The mean serum concentration of fentanyl given in the half-sized 2.5-mg formulation was 0.286 ng/ml, which was approximately one-half of the concentration of the full-sized 2.5-mg formulation, 0.544 ng/ml. Therefore the 2.5-mg fentanyl patch, applied using the one-half procedure we developed, is clinically useful.

  20. Effect of lidocaine patches on upper trapezius EMG activity and pain intensity in patients with myofascial trigger points: A randomized clinical study.

    PubMed

    Firmani, Mónica; Miralles, Rodolfo; Casassus, Rodrigo

    2015-04-01

    To compare the effects of 5% lidocaine patches and placebo patches on pain intensity and electromyographic (EMG) activity of an active myofascial trigger point (MTrP) of the upper trapezius muscle. Thirty-six patients with a MTrP in the upper trapezius muscle were randomly divided into two groups: 20 patients received lidocaine patches (lidocaine group) and 16 patients received placebo patches (placebo group). They used the patches for 12 h each day, for 2 weeks. The patch was applied to the skin over the upper trapezius MTrP. Spontaneous pain, pressure pain thresholds, pain provoked by a 4-kg pressure applied to the MTrP and trapezius EMG activity were measured before and after treatment. Baseline spontaneous pain values were similar in both groups and significantly lower in the lidocaine group than the placebo group after treatment. The baseline pressure pain threshold was significantly lower in the lidocaine group, but after treatment it was significantly higher in this group. Baseline and final values of the pain provoked by a 4-kg pressure showed no significant difference between the groups. Baseline EMG activity at rest and during swallowing of saliva was significantly higher in the lidocaine group, but no significant difference was observed after treatment. Baseline EMG activity during maximum voluntary clenching was similar in both groups, but significantly higher in the lidocaine group after treatment. These clinical and EMG results support the use of 5% lidocaine patches for treating patients with MTrP of the upper trapezius muscle.

  1. Effects of pretreatment with a urea-containing emollient on nickel allergic skin reactions.

    PubMed

    Kuzmina, Natalia; Nyrén, Miruna; Lodén, Marie; Edlund, Fredrik; Emtestam, Lennart

    2005-01-01

    The aim of this study was to evaluate the effect of a moisturizer containing urea on allergic contact dermatitis. Twenty-five nickel-sensitized patients and five controls (non-sensitized volunteers) applied such a moisturizer on the volar side of one forearm twice daily for 20 days, while the other forearm served as the control. After treatment with the moisturizer, patch tests with 0%, 0.5% and 2% NiSO4 in petrolatum were applied in a randomized manner on each arm. After 72 h, the skin reactions were blindly evaluated by clinical scoring and by measuring transepidermal water loss and electrical impedance. After treatment, the baseline transepidermal water loss values were lower and the baseline magnitude impedance index values were higher on the pretreated forearm. According to clinical scoring and measurements with the two physical measurement techniques, the degree of the patch test reactions was equal. All control subjects had negative nickel tests. We concluded that the skin reactivity to nickel in nickel-sensitized patients is not significantly affected by use of the urea-containing moisturizer.

  2. Patterns of cosmetic contact allergy.

    PubMed

    Castanedo-Tardan, Mari Paz; Zug, Kathryn A

    2009-07-01

    Certain patterns of dermatitis, such as those affecting the face, eyelids, lips, and neck, should raise the suspicion of a cosmetic-related contact allergy. Patch testing with a broad screening series, supplemented by a patient's own personal care products, should be considered when evaluating patients with suspected cosmetic dermatitis. Once the offending allergen is identified, an avoidance regimen should be established to avoid further exposure.

  3. Comparison of Enhancement of Analgesic Effect of Intrathecal Neostigmine by Intrathecal Clonidine and Transdermal Nitroglycerin Patch on Bupivacaine Spinal Anesthesia.

    PubMed

    Mammen, Mathew V; Tripathi, Manoj; Chandola, Harish C; Tyagi, Amit; Bais, Prateek Singh; Sanjeev, Om Prakash

    2017-01-01

    Relief of pain is very important goal intraoperatively and postoperatively. Neostigmine has been used successfully intrathecally with other agents such as clonidine and opioids for pain relief. This study aims to compare and evaluate the efficacy and safety of combining intrathecal (IT) neostigmine with IT clonidine and transdermal nitroglycerin (tNTG) patch for the relief of pain in patients after surgery. This was a randomized, prospective, and comparative study. In this study, recruited patients were randomly allocated into three groups. Groups I, II, and III received intrathecally 25 μg of neostigmine + 15 mg hyperbaric 0.5% bupivacaine, 25 μg of neostigmine + 25 μg clonidine + 15 mg hyperbaric 0.5% bupivacaine, and 25 μg of neostigmine + tNTG patch (3 cm × 5 cm, 5 mg/24 h) +15 mg hyperbaric 0.5% bupivacaine, respectively. Heart rate, mean arterial pressure, analgesic properties, and complications were assessed and compared among groups. Mean and standard deviation were calculated. Test of analysis between two groups was done by t -test and among three groups by ANOVA, then P value was calculated. Duration of analgesia was significantly longer in Group III in comparison to Group II (7.142 ± 1.81 vs. 4.408 ± 0.813 h) and was significantly longer in Group II in comparison to Group I (4.408 ± 0.813 vs. 2.583 ± 0.493 h). Analgesic requirement was significantly less in Group III in comparison to Group II (1.9 ± 0.76 vs. 2.5 ± 0.51) and was significantly less in Group II in comparison to Group I (2.5 ± 0.51 vs. 3.1 ± 0.48). Sedation score was found significantly high in Group II than other groups. Both IT clonidine and tNTG patch with bupivacaine + neostigmine spinal anesthesia were found effective in pain control. Results were found better with tNTG patch.

  4. Patch test responses to Malassezia pachydermatis in healthy basset hounds and in basset hounds with Malassezia dermatitis.

    PubMed

    Bond, R; Patterson-Kane, J C; Perrins, N; Lloyd, D H

    2006-08-01

    The effects of the patch test application of Malassezia pachydermatis extracts were evaluated in seven healthy basset hounds and in seven basset hounds with Malassezia dermatitis. Antigens (4 and 0.4 mg/ml) and saline controls were applied for 48 h using filter paper discs in Finn chambers. One healthy basset hound and five affected hounds showed positive patch test reactivity to the yeast antigens. Positive patch test reactions were characterized histologically by mild epidermal hyperplasia and mild to moderate perivascular, periadnexal and interstitial infiltrates of neutrophils and CD3+ lymphocytes. Immediate intradermal test reactivity to M. pachydermatis antigens was seen in one healthy and one affected hound, whereas delayed intradermal test reactivity was seen in six healthy hounds and five affected hounds. This study indicates that patch test reactivity to M. pachydermatis antigen may occur in healthy basset hounds, and in contrast to delayed intradermal test reactivity, is more frequent in basset hounds with Malassezia dermatitis.

  5. The sensitization potential of sunscreen after ablative fractional skin resurfacing using modified human repeated insult patch test.

    PubMed

    Boonchai, Waranya; Sathaworawong, Angkana; Wongpraparut, Chanisada; Wanitphakdeedecha, Rungsima

    2015-10-01

    Ablative fractional skin resurfacing has become popular and proven to be useful in treating scars, photoaging and wrinkles. Although post-inflammatory hyperpigmentation (PIH) is the most common complication especially in dark-skinned patients like Asian. Several modalities have been used to overcome the PIH. To determine the sensitization potential of sunscreen applied immediately after ablative fractional skin resurfacing. Sixty volunteers were recruited. Of these 30 subjects were from previous ablative fractional skin resurfacing study who applied broad-spectrum sunscreen containing anti-inflammatory agent starting on the first day after resurfacing and another 30 non-resurfacing subjects had applied the same sunscreen on the intact skin. All subjects were patch/photopatch tested for sensitization study by using modified human repeated insult patch test (HRIPT). There were significantly higher sensitization rate of UV-filter, octocrylene and the sunscreen in resurfacing group than in non-resurfacing group. Early application of sunscreen after ablative fractional skin resurfacing has increased the incidence of sensitization potential of sunscreen. The sunscreen is recommended to start using from D3 after fractional ablative skin resurfacing to ensure the complete recovery of skin barrier and minimize the risk of sensitization.

  6. Training a cell-level classifier for detecting basal-cell carcinoma by combining human visual attention maps with low-level handcrafted features

    PubMed Central

    Corredor, Germán; Whitney, Jon; Arias, Viviana; Madabhushi, Anant; Romero, Eduardo

    2017-01-01

    Abstract. Computational histomorphometric approaches typically use low-level image features for building machine learning classifiers. However, these approaches usually ignore high-level expert knowledge. A computational model (M_im) combines low-, mid-, and high-level image information to predict the likelihood of cancer in whole slide images. Handcrafted low- and mid-level features are computed from area, color, and spatial nuclei distributions. High-level information is implicitly captured from the recorded navigations of pathologists while exploring whole slide images during diagnostic tasks. This model was validated by predicting the presence of cancer in a set of unseen fields of view. The available database was composed of 24 cases of basal-cell carcinoma, from which 17 served to estimate the model parameters and the remaining 7 comprised the evaluation set. A total of 274 fields of view of size 1024×1024  pixels were extracted from the evaluation set. Then 176 patches from this set were used to train a support vector machine classifier to predict the presence of cancer on a patch-by-patch basis while the remaining 98 image patches were used for independent testing, ensuring that the training and test sets do not comprise patches from the same patient. A baseline model (M_ex) estimated the cancer likelihood for each of the image patches. M_ex uses the same visual features as M_im, but its weights are estimated from nuclei manually labeled as cancerous or noncancerous by a pathologist. M_im achieved an accuracy of 74.49% and an F-measure of 80.31%, while M_ex yielded corresponding accuracy and F-measures of 73.47% and 77.97%, respectively. PMID:28382314

  7. Concentrations and stability of methyl methacrylate, glutaraldehyde, formaldehyde and nickel sulfate in commercial patch test allergen preparations.

    PubMed

    Siegel, Paul D; Fowler, Joseph F; Law, Brandon F; Warshaw, Erin M; Taylor, James S

    2014-05-01

    Epicutaneous patch tests are used to reproduce allergy and diagnose allergic contact dermatitis. Reliable allergen test preparations are required. The purpose of the present study was to measure the actual concentrations of nickel(II) sulfate hexahydrate (NiSO4 ), methyl methacrylate, formaldehyde, and glutaraldehyde, and to compare them with the labelled concentrations, in commercial patch test allergen preparations found in dermatology clinics where patch testing is routinely performed. The commercial in-date and out-of-date patch test allergen preparations concentrations of NiSO4 , methyl methacrylate, formaldehyde and glutaraldehyde from one to three participating clinics were analysed with chromatographic or wet chemical techniques. NiSO4 and formaldehyde concentrations were at or above the labelled concentrations; however, formaldehyde loss occurred with storage. NiSO4 particulate was uniformly distributed throughout the petrolatum. 'In-use' methyl methacrylate reagent syringes all contained ≤ 56% of the 2% label concentration, with no observable relationship with expiration date. Lower methyl methacrylate cocentrations were consistently measured at the syringe tip end, suggesting loss resulting from methyl methacrylate's volatility. The concentrations of glutaraldehyde patch test allergen preparations ranged from 27% to 45% of the labelled (1% in pet.) concentration, independently of expiration date. Some false-negative methyl methacrylate, formaldehyde or glutaraldehyde patch test results may be attributable to instability of the test preparations. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Nicotine patches and quitline counseling to help hospitalized smokers stay quit: study protocol for a randomized controlled trial.

    PubMed

    Cummins, Sharon; Zhu, Shu-Hong; Gamst, Anthony; Kirby, Carrie; Brandstein, Kendra; Klonoff-Cohen, Hillary; Chaplin, Edward; Morris, Timothy; Seymann, Gregory; Lee, Joshua

    2012-08-01

    Hospitalized smokers often quit smoking, voluntarily or involuntarily; most relapse soon after discharge. Extended follow-up counseling can help prevent relapse. However, it is difficult for hospitals to provide follow-up and smokers rarely leave the hospital with quitting aids (for example, nicotine patches). This study aims to test a practical model in which hospitals work with a state cessation quitline. Hospital staff briefly intervene with smokers at bedside and refer them to the quitline. Depending on assigned condition, smokers may receive nicotine patches at discharge or extended quitline telephone counseling post-discharge. This project establishes a practical model that lends itself to broader dissemination, while testing the effectiveness of the interventions in a rigorous randomized trial. This randomized clinical trial (N = 1,640) tests the effect of two interventions on long-term quit rates of hospitalized smokers in a 2 x 2 factorial design. The interventions are (1) nicotine patches (eight-week, step down program) dispensed at discharge and (2) proactive telephone counseling provided by the state quitline after discharge. Subjects are randomly assigned into: usual care, nicotine patches, telephone counseling, or both patches and counseling. It is hypothesized that patches and counseling have independent effects and their combined effect is greater than either alone. The primary outcome measure is thirty-day abstinence at six months; a secondary outcome is biochemically validated smoking status. Cost-effectiveness analysis is conducted to compare each intervention condition (patch alone, counseling alone, and combined interventions) against the usual care condition. Further, this study examines whether smokers' medical diagnosis is a moderator of treatment effect. Generalized linear (binomial) mixed models will be used to study the effect of treatment on abstinence rates. Clustering is accounted for with hospital-specific random effects. If this model is effective, quitlines across the U.S. could work with interested hospitals to set up similar systems. Hospital accreditation standards related to tobacco cessation performance measures require follow-up after discharge and provide additional incentive for hospitals to work with quitlines. The ubiquity of quitlines, combined with the consistency of quitline counseling delivery as centralized state operations, make this partnership attractive. Smoking cessation in hospitalized smokers NCT01289275. Date of registration February 1, 2011; date of first patient August 3, 2011.

  9. Further important sensitizers in patients sensitive to fragrances.

    PubMed

    Frosch, P J; Johansen, J D; Menné, T; Pirker, C; Rastogi, S C; Andersen, K E; Bruze, M; Goossens, A; Lepoittevin, J P; White, I R

    2002-08-01

    The aim of this study was to determine the frequency of responses to selected fragrance materials in consecutive patients patch tested in 6 dermatological centres in Europe. 1855 patients were evaluated with the 8% fragrance mix (FM) and 14 other frequently used well-defined fragrance chemicals (series I). Each patient was classified regarding a history of adverse reactions to fragrances: certain, probable, questionable, none. Reactions to FM occurred in 11.3% of the subjects. The 6 substances with the highest reactivity following FM were Lyral (2.7%), citral (1.1%), farnesol P (0.5%), citronellol (0.4%), hexyl cinnamic aldehyde (0.3%), and coumarin (0.3%). 41 (2.2%) of the patients reacted only to materials of series I and not to FM. 6.6% of 1855 patients gave a history of adverse reactions to fragrances which was classified as certain. This group reacted to FM only in 41.1%, to series I and FM in 12.0% and to series I only in 7.2%. 74.3% of the 39 patients reacting to both FM and 1 of the materials of series I had any type of positive fragrance history, which was significantly higher in comparison to those with isolated reactions to series I (53.6% of 41), p = 0.04. The study identified further sensitizers relevant for patch testing of patients with contact dermatitis, of which Lyral is the most important single chemical.

  10. Patterns of use of a free nicotine patch program for Medicaid and uninsured patients.

    PubMed Central

    Jaén, C. R.; Cummings, K. M.; Shah, D.; Aungst, W.

    1997-01-01

    This study assessed the use and effectiveness of a free nicotine patch program among Medicaid and uninsured smokers. Patterns of patch use, associated behaviors with quit attempt, side effects, and self-reported abstinence from smoking for 6 months were evaluated prospectively among patients from five urban family practice offices and a nicotine dependence clinic located in a comprehensive cancer center in Western New York. Results indicated that the majority of participants used the program as intended, and 90% of the participants found the patch useful in their quit attempt. Fourteen percent of participants were abstinent for 6 months or more. We found no support for inappropriate use of transdermal nicotine patches among patients with no health insurance or those on Medicaid. Transdermal nicotine patches are an effective cessation aid for smokers. Given the tall of the consequences of smoking on health costs, barriers to access to effective treatment for smoking cessation among individuals covered by Medicaid for health insurance need to be eliminated. PMID:9170833

  11. A Rare Case of Oestrogen Dermatitis.

    PubMed

    Bourgeault, Emilie; Bujold, Janie; Doucet, Marie-Eve

    Oestrogen dermatitis is a rare disorder characterised by cyclical eruptions in association with a woman's menstrual cycle. A 43-year-old woman with an 8-year history of cyclical inguinal dermatitis, with a negative patch test, was tested with intradermal progesterone and oestrogen. Intradermal testing was positive for oestrogen only. In a female patient with cyclical dermatitis, it is important to consider oestrogen or progesterone dermatitis in the differential diagnosis.

  12. Oral allergy syndrome in a child provoked by royal jelly.

    PubMed

    Paola, Fantini; Pantalea, Delle Donne; Gianfranco, Calogiuri; Antonio, Ferrannini; Angelo, Vacca; Eustachio, Nettis; Elisabetta, Di Leo

    2014-01-01

    Royal jelly has been demonstrated to have several physiological activities. However, in the literature, different reactions induced by royal jelly are reported. We describe a case of seven-year-old child that was referred to our observation for two episodes of oral allergy syndrome (OAS) that appeared ten minutes after ingestion of royal jelly. Skin prick test with standard panel of inhalant and food allergens, a prick-to-prick test using the royal jelly's extract responsible for patient's reactions, and royal jelly patch test with extemporaneous preparation were performed. The specific IgE by ImmunoCAP System method versus Hymenoptera venom, inhalant allergens, food allergens, and lipid transfer proteins was dosed. According to the positive reactions to royal jelly both by prick-by-prick test and by a first reading patch test, royal jelly immediate hypersensitivity was diagnosed. According to the positive response for almond in both in vivo and in vitro tests we can think of the royal jelly contamination with almond pollen as possible cause of patient's reaction. Moreover, from the results of specific IgE titers versus Compositae pollens, we have argued the possibility that this case of royal jelly allergy could be explained also by the mechanism of cross-reaction with Compositae pollens.

  13. Oral Allergy Syndrome in a Child Provoked by Royal Jelly

    PubMed Central

    Paola, Fantini; Pantalea, Delle Donne; Gianfranco, Calogiuri; Antonio, Ferrannini; Angelo, Vacca; Eustachio, Nettis; Elisabetta, Di Leo

    2014-01-01

    Royal jelly has been demonstrated to have several physiological activities. However, in the literature, different reactions induced by royal jelly are reported. We describe a case of seven-year-old child that was referred to our observation for two episodes of oral allergy syndrome (OAS) that appeared ten minutes after ingestion of royal jelly. Skin prick test with standard panel of inhalant and food allergens, a prick-to-prick test using the royal jelly's extract responsible for patient's reactions, and royal jelly patch test with extemporaneous preparation were performed. The specific IgE by ImmunoCAP System method versus Hymenoptera venom, inhalant allergens, food allergens, and lipid transfer proteins was dosed. According to the positive reactions to royal jelly both by prick-by-prick test and by a first reading patch test, royal jelly immediate hypersensitivity was diagnosed. According to the positive response for almond in both in vivo and in vitro tests we can think of the royal jelly contamination with almond pollen as possible cause of patient's reaction. Moreover, from the results of specific IgE titers versus Compositae pollens, we have argued the possibility that this case of royal jelly allergy could be explained also by the mechanism of cross-reaction with Compositae pollens. PMID:24799914

  14. Extinction is not a natural consequence of unilateral spatial neglect: evidence from contrast detection experiments.

    PubMed

    Pavlovskaya, Marina; Soroker, Nachum; Bonneh, Yoram

    2007-06-15

    To investigate whether the expression of visual extinction is dependent upon the contralesional low saliency existing in neglect, we tested stroke patients with neglect and extinction, as well as normal controls, on detection of a peripheral Gabor patch, while a competing patch was presented simultaneously on the other side. To compensate for uneven saliency we set the contrast level relative to the detection threshold on each side. Patients showed contralesional extinction even for stimuli set at threshold level. They differed from controls in their sensitivity to changes in relative contrast between sides, showing stronger tendency for extinction and requiring much higher contrast increments in the target patch in order to eliminate extinction. The differences between normal and pathological extinction, shown despite compensation for contralesional perceptual attenuation due to neglect, suggest an additional extinction-specific deficit related to an abnormal interplay between the bilaterally presented stimuli. These findings have important theoretical implications concerning the relationship between neglect and extinction. They demonstrate that the hypothetical 'attentional gradient', taken to explain reduced saliency of stimuli in the neglected side, cannot fully account for the phenomenon of extinction.

  15. Contact allergic dermatitis from melamine formaldehyde resins in a patient with a negative patch-test reaction to formaldehyde.

    PubMed

    García Gavin, Juan; Loureiro Martinez, Manuel; Fernandez-Redondo, Virginia; Seoane, Maria-José; Toribio, Jaime

    2008-01-01

    Melamine paper is a basic material used in the furniture industry for home and office interiors. Contact allergic dermatitis from melamine formaldehyde resins (MFRs) should be considered in patients who work on melamine paper impregnation lines. We report a case of a 28-year-old female plywood worker who developed eczema on the dorsal side of her hands and wrists after 2 years of working on the melamine paper impregnation line. She had a relevant positive patch-test reaction to MFR, with a negative reaction to formaldehyde. Contact dermatitis due to MFR is not common, and it is usually related to products that are not fully cured or to close contact with intermediate products on the assembly line. Formaldehyde release from MFR can explain most of the positive responses. To our knowledge, this is the first report of MFR contact allergic dermatitis in a worker on a melamine paper impregnation line.

  16. Drug profile: transdermal rivastigmine patch in the treatment of Alzheimer disease.

    PubMed

    Emre, Murat; Bernabei, Roberto; Blesa, Rafael; Bullock, Roger; Cunha, Luis; Daniëls, Hugo; Dziadulewicz, Edward; Förstl, Hans; Frölich, Lutz; Gabryelewicz, Tomasz; Levin, Oleg; Lindesay, James; Martínez-Lage, Pablo; Monsch, Andreas; Tsolaki, Magda; van Laar, Teus

    2010-08-01

    Cholinesterase inhibitors constitute one of the mainstays of treatment of Alzheimer disease (AD). Gastrointestinal side effects, difficulty accessing therapeutic doses and poor patient compliance have been identified as barriers to effective treatment with these substances. The rivastigmine transdermal patch provides continuous delivery of drug through the skin into the bloodstream, avoiding the fluctuations in plasma concentration associated with oral administration. This pharmacokinetic profile is associated with reduced side effects, resulting in easier access to expected target doses. These benefits, along with other practical advantages of the transdermal patch, may contribute to enhanced patient compliance. Here, we present a review of the current literature on rivastigmine patch, and offer advice based on our own collective clinical experience. Rivastigmine patch provides an efficient option for managing patients with AD, to be considered among the first line therapies for the disease.

  17. Monitoring Pregnant Women’s Illicit Opiate and Cocaine Use With Sweat Testing

    PubMed Central

    Brunet, Bertrand R.; Barnes, Allan J.; Choo, Robin E.; Mura, Patrick; Jones, Hendrée E.; Huestis, Marilyn A.

    2011-01-01

    Dependence on illicit drugs during pregnancy is a major public health concern as there may be associated adverse maternal, fetal, and neonatal consequences. Sweat patches (n = 389) were collected from 39 pregnant volunteers who provided written informed consent for this Institutional Review Board-approved protocol and wore patches, replaced approximately weekly, from study entry until delivery. Patches were analyzed for opiates (heroin, 6-acetylmor-phine, 6-acetylcodeine, morphine and codeine) and cocaine (cocaine, benzoylecgonine, ecgonine methyl ester, anhydroecgonine methyl ester) by solid phase extraction and gas chromatography mass spectrometry. Seventy-one percent (276) of collected sweat patches were ≥5 ng per patch (limit of quantification) for one or more analytes. Cocaine was present in 254 (65.3%) patches in concentrations ranging from 5.2 to 11,835 ng per patch with 154 of these high enough to satisfy the proposed Substance Abuse and Mental Health Services Administration guidelines for a confirmatory drug test (25 ng per patch). Interestingly, 6-acetylmorphine was the most prominent opiate analyte documented in 134 patches (34.4%) with 11.3% exceeding the proposed opiate Substance Abuse and Mental Health Services Administration cut-off (25 ng per patch). Heroin was identified in fewer patches (77), but in a similar concentration range (5.3–345.4 ng per patch). Polydrug use was evident by the presence of both cocaine and opiate metabolites in 136 (35.0%) patches. Sweat testing is an effective method for monitoring abstinence or illicit drug use relapse in this high-risk population of pregnant opiate- and/or cocaine-dependent women. PMID:19927046

  18. Validation of a novel epicutaneous delivery system for patch testing of house dust mite-hypersensitive dogs.

    PubMed

    Olivry, Thierry; Linder, Keith E; Paps, Judy S; Bizikova, Petra; Dunston, Stan; Donne, Nathalie; Mondoulet, Lucie

    2012-12-01

    Patch tests with allergens are used for the evaluation of cellular hypersensitivity to food and environmental allergens in dogs and humans with atopic dermatitis. Viaskin is a novel allergen epicutaneous delivery system that enhances epidermal allergen capture by immune cells. To compare the use of Viaskin and Finn chamber patch tests in dogs hypersensitive to mite allergens. Empty control or Dermatophagoides farinae house dust mite-containing Viaskin or Finn chamber patches were applied to the thoracic skin of six mite-hypersensitive Maltese-beagle crossbred atopic dogs. Lesions were graded 49 and 72 h after patch test application, and skin biopsies were collected after 72 h. Overall microscopic inflammation, eosinophil and T-lymphocyte infiltrations were scored. Positive macroscopic patch test reactions developed at five of six Viaskin application sites and four of six Finn chamber application sites. Median microscopic epidermal and dermal inflammation, as well as eosinophil and CD3 T-lymphocyte dermal scores were always higher in biopsies collected at Viaskin than at Finn chamber sites. Microscopic inflammation scores were significantly higher after mite allergen-containing Viaskin compared with empty patches, but this was not the case for mite-containing Finn chambers compared with control chambers. Scores obtained using Viaskin were not significantly different from those obtained using Finn chambers. Macroscopic and microscopic scores were significantly correlated. In mite-allergic dogs, Viaskin epicutaneous delivery systems appear to induce stronger allergen-specific inflammation than currently used Finn chamber patch tests. Consequently, Viaskin patches might offer a better alternative for screening cellular hypersensitivity to food and environmental allergens. © 2012 The Authors. Veterinary Dermatology © 2012 ESVD and ACVD.

  19. Initial Experience and Early Results of Mitral Valve Repair with Cardiocel Pericardial Patch.

    PubMed

    Tomšič, Anton; Bissessar, Daniella D; van Brakel, Thomas J; Marsan, Nina Ajmone; Klautz, Robert J M; Palmen, Meindert

    2018-06-07

    To assess the performance of a tissue engineering process-treated bovine pericardium patch (CardioCel) in the setting of reconstructive mitral valve surgery. Between 3/2014 and 4/2016, 30 patients (57.2±14.3 years, 27% female) underwent mitral valve leaflet repair with a CardioCel patch. Perioperative mortality was 7% (2 patients, non-graft-related). In 28 remaining patients, pre-discharge echocardiography demonstrated good repaired valve function. At a mean follow-up of 1.7±0.9 years, 3 additional deaths occurred (2 due to infective endocarditis, 1 non-cardiac related). On follow-up echocardiography [follow-up time 1.7±0.8 years, available for 26/28 (93%) hospital survivors], recurrent regurgitation was seen in 2 patients (both infective endocarditis) and 1 underwent reoperation (no infection at the level of patch repair was observed). In the remaining patients, the most recent echocardiogram demonstrated ≤mild regurgitation and stable gradients. The thickness and echodensity of the implanted patch on follow-up echocardiograms were comparable with postoperative echocardiograms. Initial results of the CardioCel patch in mitral valve repair surgery are satisfactory. The resistance to infection and late degeneration will need to be assessed in the future. Copyright © 2018. Published by Elsevier Inc.

  20. When is it safe to stop patching?

    PubMed

    Oster, J G; Simon, J W; Jenkins, P

    1990-12-01

    Prior reports indicate that about half of amblyopia patients successfully treated with occlusion subsequently require maintenance patching. This retrospective study was designed to discover what clinical characteristics might be associated with a stable outcome following primary occlusion. Included were 188 patients who: (1) had amblyopia related to strabismus, anisometropia or media opacity; and (2) were followed up for at least one year after successful primary occlusion. Patients who did not comply with treatment or who did not achieve equal vision were excluded. Their ages ranged from 2 to 119 months (mean 29 months). Eighty-eight patients (47%) who required no further occlusion were designated the clinically stable group (CSG). The remaining 100 (53%), who subsequently needed patching because of unequal acuities, constituted the maintenance patching group (MPG). CSG patients were older at the beginning (mean 33 months) and at the end (mean 40 months) of primary occlusion than were MPG patients (means 26 and 31 months). Primary occlusion was more likely to have been discontinued because of equal recognition acuities in CSG patients, while equal fixation behaviour or preferential looking was more likely in MPG patients. Distribution of diagnoses, severity of amblyopia at presentation, and length of follow-up were similar in the two groups. Visual outcomes at last follow-up were slightly better in the CSG (p = 0.002). We conclude that, in general, patching can be safely discontinued after the third birthday. Although follow-up after primary occlusion is important to ensure stable results in all patients, preverbal children are more likely to require maintenance patching.

  1. Argon plasma coagulation of gastric inlet patches for the treatment of globus sensation: it is an effective therapy in the long term.

    PubMed

    Klare, P; Meining, A; von Delius, S; Wolf, P; Konukiewitz, B; Schmid, R M; Bajbouj, M

    2013-01-01

    To determine the long-term effect of argon plasma coagulation (APC) of gastric inlet patches in the cervical esophagus for patients suffering from globus sensation. We intended to follow up all patients between 2004 and 2011 (n = 49) who received argon plasma ablation of gastric inlet patches for globus sensation at our clinic. Symptoms were assessed by a visual analogue scale (VAS) in 31 of 49 patients. Follow-up endoscopy of the upper gastrointestinal tract was performed to confirm residual or relapsed cervical inlet patches. After a median period of 27 months, APC was assessed as a successful therapy in 23 of 31 patients (74%). VAS scores decreased significantly from 7.6 to 4.0 in the long term. Twenty-two of 31 patients were willing to undergo follow-up endoscopy. Endoscopy revealed recurrent/residual gastric inlet patches after APC in 11 of 22 cases. These patients suffered from a significant relapse of symptoms in the postinterventional period (p < 0.001). This retrospective study indicates that APC of gastric inlet patches for the treatment of globus sensation might be a sufficient therapy option. Recurrences or residual heterotopic gastric mucosa are possible and seem to be associated with a relapse of symptoms. Therefore, endoscopic follow-up and retreatment might be necessary if globus sensation is not sufficiently eliminated. © 2013 S. Karger AG, Basel.

  2. Cement-Induced Chromate Occupational Allergic Contact Dermatitis.

    PubMed

    Kridin, Khalaf; Bergman, Reuven; Khamaisi, Mogher; Zelber-Sagi, Shira; Weltfriend, Sara

    2016-01-01

    Hexavalent chromium in cement is a common cause of occupational allergic contact dermatitis (OACD). Analysis of patch test data during 1999 to 2013 was done. Patients with cement-induced chromate OACD filled the Dermatology Life Quality Index, graded 1 to 5. Of 4846 consecutive patients who were patch tested, 146 (3%) were chromate-sensitive. Of 46 (31.5%) who presented with chromate OACD, 27 (59%) had cement-induced chromate OACD. The proportion of chromate-sensitive patients with clinically relevant cement exposure increased from 7.7% in 2002 to 2004 to 28.7% in 2011 to 2013 (P = 0.04). The median age of presentation was younger than for other chromate-sensitive patients (32 vs 42 years). Hand eczema (88.9%) was the most frequent clinical presentation. Of the 27 with cement-induced chromate OACD, 21 (77.8%) had ongoing dermatitis at the time of the review. Although 14/27 (51.9%) changed their occupation to avoid exposure to cement, symptoms persisted in 9/14 (64.3%). Prolonged exposure to cement before development of symptoms was associated with chronicity. All the symptomatic patients experienced at least a moderate effect on their quality of life (grade 3 or higher on the Dermatology Life Quality Index). We recommend the adoption of the European legislation in Israel, to reduce the prevalence of chromate OACD from cement.

  3. Influence of Surface Coating on Metal Ion Release: Evaluation in Patients With Metal Allergy.

    PubMed

    Thomas, Peter; Weik, Thomas; Roider, Gabriele; Summer, Burkhard; Thomsen, Marc

    2016-05-01

    Nickel, chromium, and cobalt in stainless steel and Cobalt-chrome-molybdenum (CoCrMo) alloys may induce allergy. The objectives of this study were to evaluate surface coating regarding ion release, patch test reactivity, and arthroplasty performance. Materials and methods included patch test in 31 patients with metal allergy and 30 patients with no allergy to stainless steel and CoCrMo disks that are uncoated or coated by titanium nitride/zirconium nitride (TiN/ZrN). Assessment include atomic absorption spectrometry of released nickel, cobalt, and chromium from the disks after exposure to distilled water, artificial sweat and culture medium. Results showed that both coatings reduced the nickel and chromium release from stainless steel and CoCrMo disks and mostly the cobalt release from the disks (maximally 11.755 µg/cm(2)/5 d to 1.624 by Ti-N and to 0.442 by ZrN). Six of the 31 patients with metal allergy reacted to uncoated disks, but none reacted to the coated disks. The current authors report on exemplary patients with metal allergy who had symptom relief by revision with surface-coated arthroplasty. The authors concluded that the surface coating may prevent cutaneous and peri-implant allergic reactions. [Orthopedics. 2016; 39(3):S24-S30.]. Copyright 2016, SLACK Incorporated.

  4. Occupational methacrylate and acrylate allergy--cross-reactions and possible screening allergens.

    PubMed

    Aalto-Korte, Kristiina; Henriks-Eckerman, Maj-Len; Kuuliala, Outi; Jolanki, Riitta

    2010-12-01

    Acrylic resin monomers, especially acrylates and methacrylates, are important occupational allergens. To analyse patterns of concomitant patch test reactions to acrylic monomers in relation to exposure, and to suggest possible screening allergens. We reviewed the patch test files for the years 1994-2009 at the Finnish Institute of Occupational Health for allergic reactions to acrylic monomers, and analysed the clinical records of sensitized patients. In a group of 66 patients allergic to an acrylic monomer, the most commonly positive allergens were three methacrylates, namely ethyleneglycol dimethacrylate (EGDMA), 2-hydroxyethyl methacrylate (2-HEMA) and 2-hydroxypropyl methacrylate (2-HPMA), and an acrylate, namely diethyleneglycol diacrylate (DEGDA). The patterns of concomitant reactions imply that exposure to methacrylates may induce cross-reactivity to acrylates, whereas exposure to acrylates usually does not lead to cross-allergy to methacrylates. Screening for triethyleneglycol diacrylate (TREGDA) in the baseline series was found to be useful, as 3 of 8 patients with diagnosed occupational acrylate allergy might have been missed without the screening. A short screening series of four allergens, EGDMA, DEGDA, 2-HPMA and pentaerythritol triacrylate (PETA), would have screened 93% of our 66 patients; each of the remaining 5 patients reacted to different acrylic monomer(s). © 2010 John Wiley & Sons A/S.

  5. Allergy Skin Tests

    MedlinePlus

    ... allergic rhinitis) Allergic asthma Dermatitis (eczema) Food allergies Penicillin allergy Bee venom allergy Latex allergy Skin tests ... check for an allergy to insect venom or penicillin. Patch test Patch testing is generally done to ...

  6. Amoxicillin rash in patients with infectious mononucleosis: evidence of true drug sensitization.

    PubMed

    Ónodi-Nagy, Katinka; Kinyó, Ágnes; Meszes, Angéla; Garaczi, Edina; Kemény, Lajos; Bata-Csörgő, Zsuzsanna

    2015-01-01

    It hasn't been clearly understood yet whether sensitization to antibiotics, the virus itself or transient loss of drug tolerance due to the virus, is responsible for the development of maculopapular exanthems following amoxicillin intake in patients with infectious mononucleosis. We aimed to examine whether sensitization to penicillin developed among patients with skin rash following amoxicillin treatment within infectious mononucleosis. Ten patients were investigated for drug sensitization by lymphocyte transformation test and six patients were further tested by prick-, intradermal and patch tests employing the penicillin's main antigens. Lymphocyte transformation test showed negative results with amoxicillin, while one patient had positive reaction to cefixime. Six patients with suspected sensitization to amoxicillin were then investigated by in vivo tests. Prick tests were negative in all six patients, but the intradermal tests showed positive reactions in four patients. Our data demonstrate that in vitro testing is not sensitive enough in determining drug sensitization to penicillin. In vivo tests should be performed to detect sensitization and indeed with skin tests our results confirmed that sensitization to aminopenicillin may develop within infectious mononucleosis.

  7. Membrane Vibration Tests Using Surface-Bonded Piezoelectric Patch Actuation

    NASA Technical Reports Server (NTRS)

    Gasper, James L.; Pappa, Richard S.

    2003-01-01

    This paper describes the status of on-going work at the NASA Langley Research Center to measure the dynamics of thin membranes. The test article is a one-meter square pre-tensioned Kapton membrane that incorporates small surface-bonded piezoelectric patches strategically positioned to excite many modes. It is shown that PVDF (polyvinylidene fluoride) and MFC (macro fiber composite) piezoelectric patch actuators provide adequate excitation energy to obtain modal frequencies and mode shapes. Results from modal tests performed on the membrane using piezoelectric patches of different sizes and positions are discussed.

  8. Double blind, randomized, placebo controlled clinical trial for the treatment of diabetic foot ulcers, using a nitric oxide releasing patch: PATHON

    PubMed Central

    Silva, Sandra Y; Rueda, Ligia C; Márquez, Gustavo A; López, Marcos; Smith, Daniel J; Calderón, Carlos A; Castillo, Juan C; Matute, Jaime; Rueda-Clausen, Christian F; Orduz, Arturo; Silva, Federico A; Kampeerapappun, Piyaporn; Bhide, Mahesh; López-Jaramillo, Patricio

    2007-01-01

    Background Diabetes Mellitus constitutes one of the most important public health problems due to its high prevalence and enormous social and economic consequences. Diabetic foot ulcers are one of the chronic complications of diabetes mellitus and constitute the most important cause of non-traumatic amputation of inferior limbs. It is estimated that 15% of the diabetic population will develop an ulcer sometime in their lives. Although novel therapies have been proposed, there is no effective treatment for this pathology. Naturally produced nitric oxide participates in the wound healing process by stimulating the synthesis of collagen, triggering the release of chemotactic cytokines, increasing blood vessels permeability, promoting angiogenic activity, stimulating the release of epidermical growth factors, and by interfering with the bacterial mitochondrial respiratory chain. Topically administered nitric oxide has demonstrated to be effective and safe for the treatment of chronic ulcers secondary to cutaneous leishmaniasis. However, due to their unstable nitric oxide release, the topical donors needed to be applied frequently, diminishing the adherence to the treatment. This difficulty has led to the development of a multilayer polymeric transdermal patch produced by electrospinning technique that guarantees a constant nitric oxide release. The main objective of this study is to evaluate the effectiveness and safety of this novel nitric oxide releasing wound dressing for the treatment of diabetic foot ulcers. Methods and design A double-blind, placebo-controlled clinical trial, including 100 diabetic patients was designed. At the time of enrollment, a complete medical evaluation and laboratory tests will be performed, and those patients who meet the inclusion criteria randomly assigned to one of two groups. Over the course of 90 days group 1 will receive active patches and group 2 placebo patches. The patients will be seen by the research group at least every two weeks until the healing of the ulcer or the end of the treatment. During each visit the healing process of the ulcer, the patient's health status and the presence of adverse events will be assessed. Should the effectiveness of the patches be demonstrated an alternative treatment would then be available to patients. Trial registration NCT00428727. PMID:17897470

  9. Cost analysis of once-daily ISMN versus twice-daily ISMN or transdermal patch for nitrate prophylaxis.

    PubMed

    Brown, R E; Kendall, M J; Halpern, M T

    1997-02-01

    To compare the costs and outcomes of treating exercise-induced angina with once- or twice-daily isosorbide mononitrate (ISMN) or transdermal patch. A decision-analytic model was designed based on published literature showing compliance and increasing symptoms and estimates from physicians on treatment patterns and worsening symptoms. Data show that patients are more compliant with once-daily ISMN (Imdur, Astra Hässle, Mölndal, Sweden) and patch regimens than with twice-daily dose. Based upon the assumption that more compliant patients are better controlled, the model found that fewer medical care resources were consumed by patients treated with the once-daily and the patch regimens. The unit cost of the twice-daily ISMN regimen is 40% of the unit cost of the once-daily. Annual costs of treating an exercise-induced angina patient are 248 pounds for Imdur compared to 250 pounds for the twice-daily ISMN and 299 pounds for the transdermal patch. Unit prices alone are not good indicators for estimating medical management costs.

  10. Medial orbital wall reconstruction with flexible Ethisorb patches.

    PubMed

    Pohlenz, P; Adler, W; Li, L; Schmelzle, R; Klatt, J

    2013-03-01

    The aim of this study was to analyse the long-term result after reconstruction of the medial orbital wall with a flexible, biodegradable material (Ethisorb). During a period of almost 8 years, 31 patients with a medial orbital wall fracture were analysed retrospectively. Inclusion criteria were patients with a maximum size fracture of the orbital medial wall measuring 1.5-2 cm(2). Exophthalmos, enophthalmos, bulbus motility, diplopia and skin sensation were investigated over a period of 6 months. In all patients, the medial orbital wall was reconstructed with Ethisorb patches. No significant intraoperative complications were detected. No postoperative infection, abscess or seroma was found in any of the patients receiving an Ethisorb patch. The advantage of the semiflexibility of the Ethisorb patch is that it supplies an anatomically correct fit to the orbital medial wall but does not require fixation by screws or the use of sutures. The low rate of reported bulbus motility disturbance, diplopia, exophthalmos and enophthalmos demonstrates acceptable results after medial orbital wall reconstruction using the Ethisorb patch.

  11. Patch testing and allergen-specific serum IgE and IgG antibodies in the diagnosis of canine adverse food reactions.

    PubMed

    Bethlehem, Simone; Bexley, Jennifer; Mueller, Ralf S

    2012-02-15

    Adverse food reaction (AFR) is a common differential diagnosis for pruritic dogs. The only way to diagnose AFR is an elimination diet of 6-8 weeks with a protein and a carbohydrate source not previously fed. In humans, patch testing has been shown to be a useful tool to diagnose food allergies. In veterinary medicine, serum food allergen-specific antibody testing is widely offered to identify suitable ingredients for such diets. The aim of this study was to determine sensitivity, specificity, negative and positive predictability of patch testing with and serum antibody testing for a variety of common food stuffs. Twenty-five allergic dogs underwent an elimination diet and individual rechallenge with selected food stuffs, food patch testing and serum testing for food-antigen specific IgE and IgG. Eleven clinically normal control dogs only were subjected to patch and serum testing. The sensitivity and specificity of the patch test were 96.7 and 89.0% respectively, negative and positive predictability were 99.3 and 63.0%. For IgE and IgG the sensitivity was 6.7 and 26.7%, specificity were 91.4 and 88.3%, the negative predictive values 80.7 and 83.7% and the positive predictive values were 15.4 and 34.8%. Based on these results, a positive reaction of a dog on these tests is not very helpful, but a negative result indicates that this antigen is tolerated well. We conclude that patch testing (and to a lesser degree serum testing) can be helpful in choosing ingredients for an elimination diet in a dog with suspected AFR. Copyright © 2012. Published by Elsevier B.V.

  12. A method to visualize transdermal nickel permeation in mouse skin using a nickel allergy patch

    PubMed Central

    Sugiyama, Tomoko; Uo, Motohiro; Wada, Takahiro; Hongo, Toshio; Omagari, Daisuke; Komiyama, Kazuo; Oikawa, Masakazu; Kusama, Mikio; Mori, Yoshiyuki

    2015-01-01

    Metal patch test is often used in clinical settings when metal-induced contact dermatitis is suspected. However, the transdermal permeation behavior of metal ions from the patch test remains unclear. Current patch tests using high concentrations of metal salt solutions have some side effects, e.g. acute skin reactions to high concentrations of metal salt. To resolve these, estimating metal ion transdermal permeation is wished. In this study, synchrotron radiation X-ray fluorescence (SR-XRF) and micro-focused particle-induced X-ray emission (micro-PIXE) were used to visualize the time-dependent Ni permeation in mouse skin. The cross-sectional diffusion of Ni was visualized in a time-dependent manner. Our results indicate that maximum Ni permeation occurs after 24 h of patch treatment, and the permeated Ni content was high in the epidermis and spread into the dermis beyond the basal layer. This method may be useful to determine the appropriate solution concentration and duration of administration for the patch test. PMID:26484550

  13. Comparison of NSAID patch given as monotherapy and NSAID patch in combination with transcutaneous electric nerve stimulation, a heating pad, or topical capsaicin in the treatment of patients with myofascial pain syndrome of the upper trapezius: a pilot study.

    PubMed

    Kim, Do-Hyeong; Yoon, Kyung Bong; Park, SangHa; Jin, Tae Eun; An, Yoo Jin; Schepis, Eric A; Yoon, Duck Mi

    2014-12-01

    This study compared the therapeutic effect of monotherapy with a nonsteroidal anti-inflammatory drug (NSAID) patch vs an NSAID patch combined with transcutaneous electric nerve stimulation (TENS), a heating pad, or topical capsaicin in the treatment of patients with myofascial pain syndrome (MPS) of the upper trapezius. A randomized, single-blind, controlled study of combination therapy for patients with MPS was performed. Ninety-nine patients were randomly assigned to one of four different self-management methods for treatment: NSAID patch (N = 25), NSAID patch + TENS (N = 24), NSAID patch + heating pad (N = 25), and NSAID patch + topical capsaicin (N = 25). The NSAID patch used in this study was a ketoprofen patch. All treatment groups were observed for 2 weeks, and the numeric rating scale (NRS) pain score, cervical active range of motion, pressure pain threshold, and Neck Disability Index were assessed. There was no significant difference between the NSAID patch alone group and the three combination therapy groups with respect to decrease in NRS score from baseline (day 0) to each period of observation. In covariate analysis, although there was no difference among the groups in most of the periods, the data at day 14 indicated a trend (P = 0.057). There were no significant differences in the other variables. We did not observe a statistical difference in improvements to the clinical variables among the four different methods. However, further studies regarding the effectiveness of a mixture of topical capsaicin and ketoprofen in patients with MPS should be considered. Wiley Periodicals, Inc.

  14. Sesquiterpene lactone mix patch testing supplemented with dandelion extract in patients with allergic contact dermatitis, atopic dermatitis and non-allergic chronic inflammatory skin diseases.

    PubMed

    Jovanović, M; Poljacki, M; Mimica-Dukić, N; Boza, P; Vujanović, Lj; Duran, V; Stojanović, S

    2004-09-01

    We investigated the value of patch testing with dandelion (Compositae) extract in addition to sesquiterpene lactone (SL) mix in selected patients. After we detected a case of contact erythema multiforme after patch testing with dandelion and common chickweed (Caryophyllaceae), additional testing with common chickweed extract was performed. A total of 235 adults with a mean age of 52.3 years were tested. There were 66 men and 169 women: 53 consecutive patients with allergic contact dermatitis (ACD); 43 with atopic dermatitis (AD); 90 non-atopics suffering from non-allergic chronic inflammatory skin diseases; 49 healthy volunteers. All were tested with SL mix 0.1% petrolatum (pet.) and diethyl ether extracts from Taraxacum officinale (dandelion) 0.1 and 3.0% pet. and from Stellaria media (common chickweed) 0.1 and 3% pet. A total of 14 individuals (5.9%) showed allergic reaction (AR) to at least 1 of the plant allergens, 4 (28.6%) to common chickweed extract, and 11 (78.6%) to Compositae allergens. These 11 persons made the overall prevalence of 4.7%: 8 (3.4%) were SL-positive and 3 (1.3%) reacted to dandelion extract. 5 persons (45.5%) had AD, 2 had ACD, 2 had psoriasis and 2 were healthy controls. The Compositae allergy was relevant in 8 cases (72.7%). The highest frequency of SL mix sensitivity (9.3%) was among those with AD. Half the SL mix-sensitive individuals had AD. ARs to dandelion extract were obtained only among patients with eczema. A total of 9 irritant reactions (IRs) in 9 individuals (3.8%) were recorded, 8 to SL mix and 1 to common chickweed extract 3.0% pet. No IR was recorded to dandelion extract (P = 0.007). Among those with relevant Compositae allergy, 50.0% had AR to fragrance mix and balsam of Peru (Myroxylon pereirae resin) and colophonium. SLs were detected in dandelion but not in common chickweed. Our study confirmed the importance of 1 positive reaction for emerging, not fully established, Compositae allergy. In conclusion, the overall prevalence of 4.7% in our study represents a basal SL mix detection rate of 3.4% reinforced and safely supplemented by testing with the dandelion extract.

  15. Localized reduction of gingival inflammation using site-specific therapy with a topical gingival patch.

    PubMed

    Samuels, Noah; Saffer, Aron; Wexler, Isaiah D; Oberbaum, Menachem

    2012-01-01

    Sites of inflammation were identified on subjects with moderate-to-severe chronic periodontitis, and were allocated to either patch placement or untreated controls, both for 24 hours. Conventional treatment with scaling and root planing was postponed during the study period. Inflammation was evaluated measuring neutrophilic activity using gingival crevicular fluid (GCF) beta-glucuronidase (b-glu) levels, and clinical response was evaluated using the gingival index (GI). A total of 26 patients were recruited and 36 sites examined, with 22 sites on which the patch was placed and 14 controls. GCF b-glu levels at 24 hours were reduced following patch placement, significantly more so than with controls (17/22 vs. 3/14 sites, respectively; p = 0.002). The patch placement resulted in a significant reduction in mean b-glu levels (-2.52 +/- 1.62), with a reduction from baseline of 29.7%. This compared to untreated controls, for whom the mean b-glu levels and percent change from baseline increased (2.14 +/- 0.89 and 33%, respectively). At 24 hours, GI response rate for treated sites was better than for control sites (18/21 vs. 7/14; p = 0.053). No adverse events were reported in either group. This pilot study indicates that a topical gingival patch promotes reduction of gingival inflammation. Further clinical testing of this novel treatment of gingival inflammation is warranted.

  16. Superior limbic keratoconjunctivitis associated with cosmetic soft contact lens wear.

    PubMed

    Fuerst, D J; Sugar, J; Worobec, S

    1983-08-01

    Thirteen patients who wore soft contact lenses were seen with a syndrome consistent with superior limbic keratoconjunctivitis. An irregular epithelial surface, punctate staining with fluorescein, and subepithelial infiltrates were found on the superior aspect of the corneas in association with hyperemia of the superior bulbar conjunctivae. The keratoconjunctivitis persisted as long as 15 months after discontinuation of lens wear. Patch testing with ophthalmic vehicle preservatives, performed on seven patients, failed to show a consistent hypersensitivity to any of the tested compounds, and three patients had used only preservative-free saline for lens care. The etiology of this syndrome is unknown.

  17. Nitroglycerin patch for the treatment of chondrodermatitis nodularis helicis: a new therapeutic option.

    PubMed

    Garrido Colmenero, Cristina; Martínez García, Eliseo; Blasco Morente, Gonzalo; Tercedor Sánchez, Jesús

    2014-01-01

    Chondrodermatitis nodularis helicis (CNH) is an inflammatory process that affects the skin and cartilage of the ear. At present, there are many treatment options, although they are not always effective. Based on previous studies where nitroglycerin 2% gel was used, we propose the use of nitroglycerin patches. The purpose of this study was to evaluate the effectiveness of nitroglycerin patches in treating CNH. We performed a prospective study in 11 patients diagnosed with CNH treated with nitroglycerin patches 5 mg, 12 hours a day for 2 months. The therapeutic effectivity was determined by the improvement in the appearance and symptoms of the lesion. Seven of 11 patients (63.6%) had a complete response. One of 11 patients (9%) did not respond completely and surgical treatment was performed. Two of 11 patients (18.1%) stopped the treatment because of headache. One of 11 patients (9%) did not complete the treatment because the said patient forgot to apply the patch every night. Transdermal nitroglycerin has demonstrated efficacy in the treatment of the symptoms and lesional appearance of CNH noninvasive manner. The success rate is comparable with other published methods and the rate of adverse effects is acceptable. © 2014 Wiley Periodicals, Inc.

  18. Allergic contact dermatitis from cocamidopropyl betaine, cocamidoamine, 3-(dimethylamino)propylamine, and oleamidopropyl dimethylamine: co-reactions or cross-reactions?

    PubMed

    Moreau, Linda; Sasseville, Denis

    2004-09-01

    We present the case of a patient with facial dermatitis caused by sensitization to cocamidopropyl betaine. The patient also had positive patch-test reactions to cocamidoamine, 3-(dimethylamino)propylamine, and oleamidopropyl dimethylamine. The presence of 3-(dimethylamino)propylamine as an impurity in all of these substances can be hypothesized to explain these simultaneous reactions.

  19. Cytokine detection for the diagnosis of chromium allergy*

    PubMed Central

    Martins, Luis Eduardo Agner Machado; dos Reis, Vitor Manoel Silva

    2013-01-01

    BACKGROUND Patch testing remains the gold standard method for the identification of the etiologic agent of allergic contact dermatitis. However, it is a subjective, time-consuming exam whose technique demands special care and which presents some contraindications, which hamper its use. In a recent study, we showed that the proliferation assay can suitably replace patch testing for the diagnosis of chromium allergy, which had been previously demonstrated only for nickel allergy. In this study, we try to refine the method by reducing the incubation period of cultures for lymphocyte proliferation assays in response to chromium. OBJECTIVE Develop an alternative or complementary diagnostic test for chromium allergic contact dermatitis. METHODS We compared the production of 9 cytokines (IFN-γ, IL-2, IL-4, IL-5, IL-10, IL-12, IL-13, IL-17 and RANTES) between 18 chromium-allergic patients and 19 controls. RESULTS Chromium increased the production of IFN-y, IL-5, IL-2 and IL-13 in allergic patients, but only IL-2 and especially IL-13 helped discriminate allergic patients from controls. The sensitivity, specificity and accuracy found with IL-13 were about 80%. CONCLUSIONS IL-13 and IL-2 detection may be used to diagnose chromium allergy in 2-day cultures. However, in general, the 6-day cultures seem to be superior for this purpose. PMID:24173176

  20. Chloroatranol, an extremely potent allergen hidden in perfumes: a dose-response elicitation study.

    PubMed

    Johansen, Jeanne Duus; Andersen, Klaus Ejner; Svedman, Cecilia; Bruze, Magnus; Bernard, Guillaume; Giménez-Arnau, Elena; Rastogi, Suresh Chandra; Lepoittevin, Jean-Pierre; Menné, Torkil

    2003-10-01

    Oak moss absolute is a long-known, popular natural extract widely used in perfumes. It is reported as the cause of allergic reactions in a significant number of those with perfume allergy. Oak moss absolute has been the target of recent research to identify its allergenic components. Recently, chloroatranol, a hitherto unknown fragrance allergen, was identified in oak moss absolute. The objective was to assess the clinical importance of chloroatranol as a fragrance allergen by characterizing its elicitation profile. 13 patients previously showing a positive patch test to oak moss absolute and chloroatranol were included, together with a control group of 10 patients without sensitization to either of the 2 materials. A serial dilution patch test was performed on the upper back with concentrations ranging from 200 to 0.0063 p.p.m. of chloroatranol in ethanol. Simultaneously, the participant performed an open test simulating the use of perfumes on the volar aspect of the forearms in a randomized and double-blinded design. A solution with 5 p.p.m. chloroatranol was used for 14 days, and, in case of no reaction, the applications were continued for another 14 days with a solution containing 25 p.p.m. All test subjects (13/13) developed an allergic reaction at the site of application of the solution containing chloroatranol. Among them, 12/13 (92%) gave a positive reaction to the 5 p.p.m. solution and 1 to 25 p.p.m. None of the controls reacted (P < 0.001). The use test was terminated at median day 4. The dose eliciting a reaction in 50% of the test subjects at patch testing was 0.2 p.p.m. In conclusion, the hidden exposure to a potent allergen widely used in perfumes has caused a highly sensitized cohort of individuals. Judged from the elicitation profile, chloroatranol is the most potent allergen present in consumer products today.

  1. [Patch testing and nickel allergy].

    PubMed

    Hansen, Sonali Rathour; Kroon, Susanne

    2008-02-14

    The prevalence of contact allergy varies between populations. 857 patients were tested for contact allergy (epicutantest; patch test) at the Department of Dermatology, Stavanger University Hospital in 2001 and 2002. Finn Chambers were placed on the upper part of the back, removed after 48 hrs and read after an additional 24 hrs. Positive reactions and other variables were recorded and data were collected retrospectively from journals. The most common allergens were metals such as nickel (nickel chloride; 40% and nickel sulphate; 23%), cobolt (11%) and dichromate (6.5%), fragrance mix (10%) and fragrance indicators such as peru balsam (9.4%), compositae (6.1%) and colophonium 5.3%. 370 (67%) women versus 139 (45%) men were positive for at least one of the allergens in the standard series (odds ratio 2.5 CI 1.83-3.23). 149 of 341 (44%) nickel positive patients had isolated reactions to nickel chloride without reacting to nickel sulphate, while only 11 (3.2%) reacted to nickel sulphate alone. 61/93 (66%) of the cobolt sensitive patients were also sensitive for nickel sulphate (OR: 8.9 CI 5.54-14.12,), while 77 (82%) tested positive for nickel chloride (OR: 9.26 CI 5.29-16.21). We detected a similar prevalence for common allergens as that reported from other skin departments in hospitals in Norway, but a higher average than that presented in other European studies.

  2. Preferences among four combination nicotine treatments.

    PubMed

    Schneider, Nina G; Koury, Margaret A; Cortner, Chris; Olmstead, Richard E; Hartman, Neil; Kleinman, Leonard; Kim, Andrew; Chaya, Craig; Leaf, David

    2006-09-01

    Acute nicotine replacement treatments (NRTs) are disliked or misused, leading to insufficient nicotine intake and poor outcome. Patches provide steady nicotine but are slow and passive. Combining systems may improve efficacy with acute NRTs tailored for compliance. To test initial reactions to and use preferences among combinations of NRTs. Smokers (n=27) tested four combination NRTs in a 5-day crossover trial: 2/4-mg gum + 15-mg patch (G/P), 2/4-mg lozenges + 15-mg patch (L/P), inhaler + 15-mg patch (I/P), and 10 mg + 15-mg patches (P/P). Subjects rated an NRT combination each day after 5-6 h of use and ranked among the NRTs after testing all treatments. Double-patches (P/P) were ranked highest for "ease of use", "safety", and "use in public". However, for "help to quit", 70% preferred some form of acute-patch combination (A/P) compared to 30% choosing P/P. For "use under stress" (an immediate need), 93% preferred A/P systems compared to 7% choosing P/P. L/P ranked lowest for "ease of use", I/P and L/P were lowest on "safety", and I/P ranked lowest for "use in public". Expectations of NRTs changed with test experience for patches (better) and lozenges (worse). In brief testing, all combinations were acceptable. P/P was favored for ease, safety, and public use, but a majority chose A/P systems for help in quitting and use under stress. Combined use is viable and needs to be made known and accessible to smokers.

  3. Simple patch closure for perforated peptic ulcer in children followed by helicobacter pylori eradication.

    PubMed

    Yildiz, Turan; Ilce, Huri Tilla; Ceran, Canan; Ilce, Zekeriya

    2014-05-01

    Peptic ulcer disease in children is rare. Therefore, the diagnosis can be missed until complications such as perforation or hemorrhage occur. Few reports have investigated the procedures and outcomes of children who have undergone operations for perforated duodenal ulcers. We report our experience with the modified Graham technique for perforated duodenal ulcers in nine children and review the literature. Methods : The records of patients operated on for a perforated duodenal ulcer in the last 8 years in two pediatric surgery centers were evaluated retrospectively. Patient demographics, symptoms, time to admission to hospital, operative findings, and postoperative clinical course were evaluated. Results : Nine children (mean age 13.2 years, range 6-170 years) were included. All patients were admitted in the first six hours after their abdominal pain started. In three patients, there was free air on plain x-rays, while the x-rays were normal in six. All perforations were located on the anterior surface of the first part of the duodenum and repaired with primary suturing and Graham patch omentoplasty. The recovery was uneventful in all patients. In five patients, urea breath tests were performed postoperatively for Helicobacter Pylori, and the results were positive. All patients underwent triple therapy with lansoprazole, amoxicillin, and clarithromycin. The mean follow-up time was 58 (range 3-94) months. Conclusions : Peptic ulcer perforation should be suspected in children who have acute abdominal pain and peritoneal signs, especially when their suffering is intense. The simple patch repair and postoperative triple therapy for Helicobacter Pylori are safe and satisfactory for treating peptic ulcer perforation in children.

  4. Pharmacokinetic Evaluation of Two Nicotine Patches in Smokers.

    PubMed

    Rasmussen, Scott; Horkan, Kathleen Halabuk; Kotler, Mitchell

    2018-02-02

    Smoking continues to be a major preventable cause of early mortality worldwide, and nicotine replacement therapy has been demonstrated to increase rates of abstinence among smokers attempting to quit. Nicotine transdermal systems (also known as nicotine patches) attach to the skin via an adhesive layer composed of a mixture of different-molecular-weight polyisobutylenes (PIBs) in a specific ratio. This randomized, single-dose, 2-treatment, crossover pharmacokinetic (PK) trial assessed the bioequivalence of nicotine patches including a replacement PIB adhesive (test) compared with the PIB adhesive historically used on marketed patches (reference). The test and reference patches were bioequivalent, as determined by the PK parameters of C max and AUC 0-t . In addition, the parameters T max and t 1/2 did not significantly differ between the 2 patches, supporting the bioequivalence finding from the primary analysis. The tolerability profiles of the patches containing the replacement and previously used PIB adhesives were similar; application-site adverse events did not significantly differ between test and reference patches. Overall, these data establish the bioequivalence of the nicotine patch with the replacement PIB adhesive formulation and the previously utilized PIB adhesive formulation. © 2018 The Authors. Clinical Pharmacology in Drug Development published by Wiley Periodicals, Inc. on behalf of The American College of Clinical Pharmacology.

  5. Patch-augmented rotator cuff repair: influence of the patch fixation technique on primary biomechanical stability.

    PubMed

    Jung, Christian; Spreiter, Gregor; Audigé, Laurent; Ferguson, Stephen J; Flury, Matthias

    2016-05-01

    There is an ongoing debate about the potential of patch augmentation to improve biomechanical stability and healing associated with rotator cuff repair. The biomechanical properties of three different patch-augmented rotator cuff repair techniques were assessed in vitro and compared with a standard repair. Dermal collagen patch augmentation may increase the primary stability and strength of the repaired tendon in vitro, depending on the technique used for patch application. Forty cadaveric sheep shoulders with dissected infraspinatus tendons were randomized into four groups (n = 10/group) for tendon repair using a knotless double-row suture anchor technique. A xenologous dermal extracellular matrix patch was used for augmentation in the three test groups using an "integrated", "cover", or "hybrid" technique. Tendons were preconditioned, cyclically loaded from 10 to 30 N at 1 Hz, and then loaded monotonically to failure. Biomechanical properties and the mode of failure were evaluated. Patch augmentation significantly increased the maximum load at failure by 61 % in the "cover" technique test group (225.8 N) and 51 % in the "hybrid" technique test group (211.4 N) compared with the non-augmented control group (140.2 N) (P ≤ 0.015). For the test group with "integrated" patch augmentation, the load at failure was 28 % lower (101.6 N) compared with the control group (P = 0.043). There was no significant difference in initial and linear stiffness among the four experimental groups. The most common mode of failure was tendon pullout. No anchor dislocation, patch disruption or knot breakage was observed. Additional patch augmentation with a collagen patch influences the biomechanical properties of a rotator cuff repair in a cadaveric sheep model. Primary repair stability can be significantly improved depending on the augmentation technique.

  6. Improvement of tuberous sclerosis complex (TSC) skin tumors during long-term treatment with oral sirolimus.

    PubMed

    Nathan, Neera; Wang, Ji-an; Li, Shaowei; Cowen, Edward W; Haughey, Mary; Moss, Joel; Darling, Thomas N

    2015-11-01

    Oral mechanistic target of rapamycin inhibitors have been shown to reduce visceral tumor volume in patients with tuberous sclerosis complex (TSC). We sought to evaluate the cutaneous response to oral sirolimus in patients with TSC and an indication for systemic treatment, including long-term effects. A retrospective analysis of 14 adult patients with TSC prescribed sirolimus to treat lymphangioleiomyomatosis was performed. Serial photographs of angiofibromas, shagreen patches, and ungual fibromas taken before, during, and after the treatment period were blinded, then assessed using the Physician Global Assessment of Clinical Condition (PGA). Microscopic and molecular studies were performed on skin tumors harvested before and during treatment. Sirolimus significantly improved angiofibromas (median treatment duration 12 months; median PGA score 4.5 [range 1.5-5]; Wilcoxon signed rank test, P = .018) and shagreen patches (median treatment duration 10 months; median PGA score 4.5 [range 3.5-5]; Wilcoxon signed rank test, P = .039), whereas ungual fibromas improved in some patients (median treatment duration 6.5 months; median PGA score 4.66 [range 2.75-5]; Wilcoxon signed rank test, P = .109). Clinical, immunohistochemical, or molecular evidence of resistance was not observed (range 5-64 months of treatment). This was a retrospective analysis limited to adult women with lymphangioleiomyomatosis. Oral sirolimus is an effective long-term therapy for TSC skin tumors, particularly angiofibromas, in patients for whom systemic treatment is indicated. Published by Elsevier Inc.

  7. Fentanyl patches: preventable overdose.

    PubMed

    2010-02-01

    Fentanyl is a potent opioid analgesic marketed for the treatment of stable intense chronic pain, particularly in the form of a transdermal patch. These delivery devices carry the same risk of adverse effects and drug interactions as conventional formulations of opioids. The patches carry an added risk of fentanyl overdose because they contain very high doses, both before and after use. High-risk situations for overdose were identified by examining the results of pharmacovigilance studies and medication error prevention programmes, as well as an observational study, case reports, and a French legal action. The main situations exposing patients to a risk of overdose are: confusion between two dose strengths, forgetting to remove the patch; accidental transfer of the patch to another person, application of more than one patch, cutting the patches, self-medication, and ingestion. Increased skin temperature facilitates fentanyl absorption and thus increases the risk of overdose; high-risk situations include fever, electric blankets, and intense physical exercise. In practice, the precautions for treatment and patch disposal must be followed exactly if this delivery system is to serve as a valid alternative to morphine for selected patients with stable intense chronic pain.

  8. Non-scarring patchy alopecia in patients with systemic lupus erythematosus differs from that of alopecia areata.

    PubMed

    Ye, Y; Zhao, Y; Gong, Y; Zhang, X; Caulloo, S; Zhang, B; Cai, Z; Yang, J; McElwee, K J; Zhang, X

    2013-12-01

    Non-scaring patchy alopecia associated with systematic lupus erythematosus (SLE) is sometimes mis-diagnosed as alopecia areata (AA). Our aim was to differentiate non-scarring patchy SLE alopecia features from patchy AA. Clinical, dermatoscopic and histopathological data from 21 SLE patients with patchy alopecia were compared with data from 21 patients with patchy AA. Incomplete alopecia was common in SLE alopecia patches, while AA patches exhibited complete alopecia. Exclamation-mark hairs, black dots, broken hair and yellow dots were common to AA, while hair shaft thinning and hypopigmentation, angiotelectasis, peripilar sign, perifollicular red dots, white dots and honeycomb pigment patterns were more common in SLE. Interfollicular polymorphous vessels were the most common angiotelectasis presentation in the SLE alopecia patches, but interfollicular arborizing vessels were significantly more common in non-hair-loss-affected SLE regions and in AA hair-loss regions. During follow-up, increased vellus hair was the earliest feature that emerged after treatment both in SLE and AA, while the earliest feature that disappeared was hair shaft hypopigmentation in SLE and broken hair in AA. After treatment, no SLE patients had relapse of alopecia, while 41.7% of AA patients did. Distinct clinical, dermatoscopic and histopathological features were found in SLE-associated alopecia regions, which were different from those of AA. Serological autoantibody tests are of value to confirm the differential diagnosis. Local angiotelectasis and vasculitis close to hair follicles may be involved in the pathogenesis of alopecia in SLE.

  9. Comparison between the efficacy of microneedling combined with 5-fluorouracil vs microneedling with tacrolimus in the treatment of vitiligo.

    PubMed

    Mina, Mary; Elgarhy, Lamia; Al-Saeid, Hanan; Ibrahim, Zeinab

    2018-03-12

    Several treatment modalities had been used for the treatment of vitiligo, but the optimal treatment has not yet been identified. To study the efficacy of microneedling with 5-flurouracil vs its efficacy with tacrolimus in the treatment of vitiligo. Twenty-five patients with vitiligo were subjected to microneedling of 2 patches of vitiligo with dermapen, then application of 5-fluorouracil to 1 patch and tacrolimus on the other patch. This procedure was repeated every 2 weeks for every patient for maximum 6 months (12 sessions). The patients were followed up for 3 months after the last session. The overall repigmentation was significantly higher in 5-fluorouracil-treated patches compared with tacrolimus. Excellent improvement occurred in 48% of 5- flurouracil-treated patches while only in 16% of tacrolimus-treated patches. In the acral parts, 40% of the patches treated with 5-fluorouracil achieved excellent improvement (repigmentation >75%), while no patch in the acral parts achieved excellent improvement with tacrolimus. However, there was significant difference between the 2 drugs,regarding inflammation, ulceration, and hyperpigmentation which occurred with 5-fluorouracil. Microneedling combined with 5-fluorouracil or tacrolimus is safe and effective treatment of vitiligo. However, 5-fluorouracil achieved a greater percentage of repigmentation than tacrolimus particularly in the acral parts. © 2018 Wiley Periodicals, Inc.

  10. Allergic contact dermatitis to cosmetics.

    PubMed

    Park, Michelle E; Zippin, Jonathan H

    2014-01-01

    Allergic contact dermatitis caused by cosmetic products is an increasing concern given the continual creation and introduction of new cosmetics to the public. This article presents an overview of how to evaluate a patient for patch testing, including common areas for cosmetic-induced dermatitis, common cosmetic allergens, and proper management. Published by Elsevier Inc.

  11. Generalized peritonitis requiring re-operation after leakage of omental patch repair of perforated peptic ulcer.

    PubMed

    Maghsoudi, Hemmat; Ghaffari, Alireza

    2011-01-01

    Peptic ulcer perforations are a common emergency, but available literature is silent on the exact definition, incidence, management, and complications of peritonitis due to omental patch leakage. Retrospective data were collected on 422 patients who underwent omental patch repair of perforated peptic ulcer between March 20, 1999 and March 20, 2006. The definitive diagnosis of perforated peptic ulcer and omental patch leakage was obtained at surgery. Seventeen (4%) patients experienced generalized peritonitis due to omental patch leakage. Mean age was 60.6 years. Mortality rate was 29.4%, and the mean hospital stay was 23.6 days. Delay in surgical approach, shock on admission, and age were all significantly associated with increased mortality. Peritonitis due to omental patch leakage can result in significant morbidity and mortality. The most common causes of omental patch leakage and operative procedures were unknown and reinsertion of omentum, respectively. Factors such as shock on admission or delayed surgery, have significantly contributed to fatal outcomes and need careful attention.

  12. Light transmission and preference of eye patches for occlusion treatment.

    PubMed

    Heo, Hwan; Park, Jung Won; Park, Sang Woo

    2013-01-01

    To investigate light transmission and preference for six eye patches for occlusion therapy. Six patches were examined, including; Ortopad Fun Pack, Ortopad Flesh, Kawamoto A-1, Kawamoto A-2, 3M Opticlude, and Everade Eye Guard. The size and the presence of a light blocking pad of patches were investigated. The amount of light transmitted through the patches was evaluated, using a digital light meter and a model eye, in three different environments; indoors with fluorescent light, outdoors on a sunny day, and strong light from illuminator. After patching the normal eye, the flash visual evoked potential (VEP) was measured. Thirty patients with amblyopia or horizontal strabismus, who received occlusion therapy as initial treatment, were included. After using all six patches, patients completed a 7-item questionnaire regarding the patch preference for size, color and shape, adhesive power, pain with removal, skin irritation after removing patch, parent's preference and overall opinion. All patches had a light-blocking pad, except the 3M Nexcare. Ortopad had the strongest light blocking power in the three environments, and the 3M Nexcare had the weakest power. In flash VEP, Ortopad and Kawamoto patches showed flat, but 3M Nexcare and Everade Eye Guard showed normal response. There were significant preferential differences among the patches in all the items of the questionnaire (P<0.05). In comparison between the patches respectively, 3M Nexcare received the lowest satisfaction in pain when removing a patch and skin irritation after removing a patch. Kawamoto A-2 received the lowest score in the overall satisfaction. We found differences in the light-blocking power and in the preference of the various patches for the occlusion treatment. This is a pilot study regarding only characteristics and preferences of patches. Further clinical studies regarding the relationship between characteristics or preferences of patches and outcomes of occlusion treatment are needed.

  13. Surface gloss and color perception of 3D objects.

    PubMed

    Xiao, Bei; Brainard, David H

    2008-01-01

    Two experiments explore the color perception of objects in complex scenes. The first experiment examines the color perception of objects across variation in surface gloss. Observers adjusted the color appearance of a matte sphere to match that of a test sphere. Across conditions we varied the body color and glossiness of the test sphere. The data indicate that observers do not simply match the average light reflected from the test. Indeed, the visual system compensates for the physical effect of varying the gloss, so that appearance is stabilized relative to what is predicted by the spatial average. The second experiment examines how people perceive color across locations on an object. We replaced the test sphere with a soccer ball that had one of its hexagonal faces colored. Observers were asked to adjust the match sphere have the same color appearance as this test patch. The test patch could be located at either an upper or lower location on the soccer ball. In addition, we varied the surface gloss of the entire soccer ball (including the test patch). The data show that there is an effect of test patch location on observers' color matching, but this effect is small compared to the physical change in the average light reflected from the test patch across the two locations. In addition, the effect of glossy highlights on the color appearance of the test patch was consistent with the results from Experiment 1.

  14. Surface gloss and color perception of 3D objects

    PubMed Central

    Xiao, Bei; Brainard, David H.

    2008-01-01

    Two experiments explore the color perception of objects in complex scenes. The first experiment examines the color perception of objects across variation in surface gloss. Observers adjusted the color appearance of a matte sphere to match that of a test sphere. Across conditions we varied the body color and glossiness of the test sphere. The data indicate that observers do not simply match the average light reflected from the test. Indeed, the visual system compensates for the physical effect of varying the gloss, so that appearance is stabilized relative to what is predicted by the spatial average. The second experiment examines how people perceive color across locations on an object. We replaced the test sphere with a soccer ball that had one of its hexagonal faces colored. Observers were asked to adjust the match sphere have the same color appearance as this test patch. The test patch could be located at either an upper or lower location on the soccer ball. In addition, we varied the surface gloss of the entire soccer ball (including the test patch). The data show that there is an effect of test patch location on observers’ color matching, but this effect is small compared to the physical change in the average light reflected from the test patch across the two locations. In addition, the effect of glossy highlights on the color appearance of the test patch was consistent with the results from Experiment 1. PMID:18598406

  15. Results of tests of K5NA and a revised formulation of EPDM/cork patch material in MSFC Hot Gas Facility

    NASA Technical Reports Server (NTRS)

    Dean, W. G.

    1982-01-01

    During prelaunch procedures at Kennedy Space Center some of the EPDM Thermal Protection System material was damaged on the Solid Rocket Booster stiffener stubs. The preferred solution was to patch the damaged areas with a cork-filled epoxy patching compound. Before this was done, however, it was requested that this patching technique be checked out by testing it in the MSFC Hot Gas Facility. Two tests were run in the HFG in 1980. The results showed the patch material to be adequate. Since that time, the formulation of the cork-filled epoxy material has been changed. It became necessary to retest this concept to be sure that the new material is as good as or better than the original material. In addition to the revised formulation material, tests were also made using K5NA as the patch material. The objectives of the tests reported herein were to: (1) compare the thermal performance of the original and the new cork-filled epoxy formulations, and (2) compare the K5NA closeout material to these epoxy materials. Material specifications are also discussed.

  16. A patch-based pseudo-CT approach for MRI-only radiotherapy in the pelvis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andreasen, Daniel, E-mail: dana@dtu.dk

    Purpose: In radiotherapy based only on magnetic resonance imaging (MRI), knowledge about tissue electron densities must be derived from the MRI. This can be achieved by converting the MRI scan to the so-called pseudo-computed tomography (pCT). An obstacle is that the voxel intensities in conventional MRI scans are not uniquely related to electron density. The authors previously demonstrated that a patch-based method could produce accurate pCTs of the brain using conventional T{sub 1}-weighted MRI scans. The method was driven mainly by local patch similarities and relied on simple affine registrations between an atlas database of the co-registered MRI/CT scan pairsmore » and the MRI scan to be converted. In this study, the authors investigate the applicability of the patch-based approach in the pelvis. This region is challenging for a method based on local similarities due to the greater inter-patient variation. The authors benchmark the method against a baseline pCT strategy where all voxels inside the body contour are assigned a water-equivalent bulk density. Furthermore, the authors implement a parallelized approximate patch search strategy to speed up the pCT generation time to a more clinically relevant level. Methods: The data consisted of CT and T{sub 1}-weighted MRI scans of 10 prostate patients. pCTs were generated using an approximate patch search algorithm in a leave-one-out fashion and compared with the CT using frequently described metrics such as the voxel-wise mean absolute error (MAE{sub vox}) and the deviation in water-equivalent path lengths. Furthermore, the dosimetric accuracy was tested for a volumetric modulated arc therapy plan using dose–volume histogram (DVH) point deviations and γ-index analysis. Results: The patch-based approach had an average MAE{sub vox} of 54 HU; median deviations of less than 0.4% in relevant DVH points and a γ-index pass rate of 0.97 using a 1%/1 mm criterion. The patch-based approach showed a significantly better performance than the baseline water pCT in almost all metrics. The approximate patch search strategy was 70x faster than a brute-force search, with an average prediction time of 20.8 min. Conclusions: The authors showed that a patch-based method based on affine registrations and T{sub 1}-weighted MRI could generate accurate pCTs of the pelvis. The main source of differences between pCT and CT was positional changes of air pockets and body outline.« less

  17. A patch test confirmed phenobarbital-induced fixed drug eruption in a child.

    PubMed

    Chadly, Zohra; Aouam, Karim; Chaabane, Amel; Belhadjali, Hichem; Abderrazzak Boughattas, Naceur; Zili, Jamel Eddine

    2014-06-01

    A-10-year-old girl was referred to our department for multiple hyperpigmented plaques. One week previously, she had been given one suppository of acetylsalicylic acid - phenobarbital for fever. Twelve hours after the drug intake the child developed pruritic red plaques on the left thigh. Six weeks after resolution of the acute reaction, patch tests were performed separately, with phenobarbital and acetylsalicylic acid. On 48-hour reading, only the phenobarbital patch test on residual pigmented lesion was positive. Because of possible cross-reactions between aromatic anticonvulsants, subsequent patch tests using carbamazepine and phenytoin on residual pigmented lesions were performed. They were all negative at 48-hour reading. To our knowledge, only two isolated pediatric cases of Phenobarbital-induced FDE have been reported in the literature. In this case report, as it was difficult to determine whether phenobarbital or acetylsalicylic acid was responsible for this reaction, subsequent patch tests allowed the identification of the culprit component since it was positive to phenobarbital.

  18. Antimicrobial allergy from polyvinyl chloride gloves.

    PubMed

    Aalto-Korte, Kristiina; Alanko, Kristiina; Henriks-Eckerman, Maj-Len; Jolanki, Riitta

    2006-10-01

    Contact allergy to plastic gloves is rare. Benzisothiazolinone is a biocide that is mainly used in industrial settings. We first suspected delayed-type contact allergy to benzisothiazolinone from polyvinyl chloride (PVC) gloves in 2004. We looked through our medical records from 1991 to 2005 to find similar cases. We found a total of 8 patients who are allergic to benzisothiazolinone and who had had exacerbations of their hand dermatitis while using PVC gloves. Patch testing revealed that 3 of them had weak allergic or doubtful reactions to the glove materials. Six of them had used Evercare Soft, Medi-Point, or Derma Grip PVC gloves, which in chemical analysis were shown to contain 9 to 32 ppm of benzisothiazolinone. Seven of the patients worked in dentistry or health care and 1 in farming. All of them had had hand dermatitis for many years. To our knowledge, there have been no previous reports of contact allergy to antimicrobial agents in plastic gloves. Benzisothiazolinone is widely used as a biocide in the manufacture of disposable PVC gloves. Small amounts of benzisothiazolinone in the gloves may sensitize those who already have hand dermatitis. We recommend that all patients with hand dermatitis while using PVC gloves should be patch tested with benzisothiazolinone.

  19. Accidental dural puncture, postdural puncture headache, intrathecal catheters, and epidural blood patch: revisiting the old nemesis.

    PubMed

    Kaddoum, Roland; Motlani, Faisal; Kaddoum, Romeo N; Srirajakalidindi, Arvi; Gupta, Deepak; Soskin, Vitaly

    2014-08-01

    One of the controversial management options for accidental dural puncture in pregnant patients is the conversion of labor epidural analgesia to continuous spinal analgesia by threading the epidural catheter intrathecally. No clear consensus exists on how to best prevent severe headache from occurring after accidental dural puncture. To investigate whether the intrathecal placement of an epidural catheter following accidental dural puncture impacts the incidence of postdural puncture headache (PDPH) and the subsequent need for an epidural blood patch in parturients. A retrospective chart review of accidental dural puncture was performed at Hutzel Women's Hospital in Detroit, MI, USA for the years 2002-2010. Documented cases of accidental dural punctures (N = 238) were distributed into two groups based on their management: an intrathecal catheter (ITC) group in which the epidural catheter was inserted intrathecally and a non-intrathecal catheter (non-ITC) group that received the epidural catheter inserted at different levels of lumbar interspaces. The incidence of PDPH as well as the necessity for epidural blood patch was analyzed using two-tailed Fisher's exact test. In the non-ITC group, 99 (54 %) parturients developed PDPH in comparison to 20 (37 %) in the ITC [odds ratio (OR), 1.98; 95 % confidence interval (CI), 1.06-3.69; P = 0.03]. Fifty-seven (31 %) of 182 patients in the non-ITC group required an epidural blood patch (EBP) (data for 2 patients of 184 were missing). In contrast, 7 (13 %) of parturients in the ITC group required an EBP. The incidence of EBP was calculated in parturients who actually developed headache to be 57 of 99 (57 %) in the non-ITC group versus 7 of 20 (35 %) in the ITC group (OR, 2.52; 95 % CI, 0.92-6.68; P = 0.07). The insertion of an intrathecal catheter following accidental dural puncture decreases the incidence of PDPH but not the need for epidural blood patch in parturients.

  20. Investigating Birth Control: Comparing Oestrogen Levels in Patients Using the Ortho Evra[R] Patch versus the Ortho-Cyclen[R] Pill

    ERIC Educational Resources Information Center

    Laurent, Theresa A.

    2008-01-01

    Recent drug studies have investigated the incidence of blood clots among patients using the Ortho Evra[R] birth control patch. In this article, the author describes an investigation of oestrogen levels in the body resulting from the application of the Ortho Evra[R] birth control patch versus daily use of Ortho-Cyclen[R] birth control pills.…

  1. Comparison of the efficacies of patching and penalization therapies for the treatment of amblyopia patients

    PubMed Central

    Cabi, Cemalettin; Sayman Muslubas, Isil Bahar; Aydin Oral, Ayse Yesim; Dastan, Metin

    2014-01-01

    AIM To compare the efficacies of patching and penalization therapies for the treatment of amblyopia patients. METHODS The records of 64 eyes of 50 patients 7 to 16y of age who had presented to our clinics with a diagnosis of amblyopia, were evaluated retrospectively. Forty eyes of 26 patients who had received patching therapy and 24 eyes of 24 patients who had received penalization therapy included in this study. The latencies and amplitudes of visual evoked potential (VEP) records and best corrected visual acuities (BCVA) of these two groups were compared before and six months after the treatment. RESULTS In both patching and the penalization groups, the visual acuities increased significantly following the treatments (P<0.05). The latency measurements of the P100 wave obtained at 1.0°, 15 arc min. Patterns of both groups significantly decreased following the 6-months-treatment. However, the amplitude measurements increased (P<0.05). CONCLUSION The patching and the penalization methods, which are the main methods used in the treatment of amblyopia, were also effective over the age of 7y, which has been accepted as the critical age for the treatment of amblyopia. PMID:24967195

  2. Complications of oral exposure to fentanyl transdermal delivery system patches.

    PubMed

    Prosser, Jane M; Jones, Brent E; Nelson, Lewis

    2010-12-01

    Fentanyl is a synthetic opioid available therapeutically as an intravenous, transbucal, or transdermal preparation. It is also used as a drug of abuse through a variety of different methods, including the oral abuse of transdermal fentanyl patches. This is a series of patients with oral fentanyl patch exposure reported to our center and represents the first series of oral fentanyl patch exposures collected outside of the postmortem setting. In this series, we examined the New York Poison Control Center database for all cases of oral abuse of fentanyl reported between January 2000 and April 2008. Twenty cases were reported, nine were asymptomatic or had symptoms of opioid withdrawal; 11 had symptoms of opioid intoxication. Eight patients were administered naloxone and all showed improvement in clinical status. Only one case resulted in a confirmed fatality-this patient had an orally adherent patch discovered at intubation. Oral exposure may result in life-threatening toxicity. Patients should be closely assessed and monitored for the opioid toxidrome, and if symptomatic, should be managed with opioid antagonists and ventilatory support.

  3. Pediatric Allergic Contact Dermatitis: Clinical and Epidemiological Study in a Tertiary Hospital.

    PubMed

    Ortiz Salvador, J M; Esteve Martínez, A; Subiabre Ferrer, D; Victoria Martínez, A M; de la Cuadra Oyanguren, J; Zaragoza Ninet, V

    Few epidemiological studies have investigated the incidence of allergic contact dermatitis in children. Underdiagnosis has been observed in some studies, with many cases in which the condition is not suspected clinically and patch tests are not performed. However, the prevalence of pediatric sensitization to allergens has been reported to be as high as 20%, and the diagnosis should therefore be contemplated as a possibility in this age group. We performed a retrospective analysis of the skin allergy database of the Dermatology Department of Consorcio Hospital General Universitario de Valencia. Children between 0 and 16 years of age diagnosed with allergic contact dermatitis in the previous 15 years (between 2000 and 2015) were included in the analysis. Epidemiological (age, sex, history of atopy) and clinical (site of the lesions, allergen series applied, positive reactions, and their relevance) variables were gathered. Patch tests had been performed on 4,593 patients during the study period. Of these, 265 (6%) were children aged between 0 and 16 years. A positive reaction to at least one of the allergens tested was observed in 144 (54.3%) patients in that group. The allergens most frequently identified were the following (in decreasing order of frequency): thiomersal, cobalt chloride, colophony, paraphenylenediamine, potassium dichromate, mercury, and nickel. The sensitization was considered relevant in 177 (61.3%) cases. More than half of the children studied showed sensitization to 1 or more allergens, with a high percentage of relevant sensitizations. All children with a clinical suspicion of allergic contact dermatitis should be referred for patch testing. As no standardized test series have been developed for this age group, a high level of clinical suspicion and knowledge of the allergens most commonly involved are required when selecting the allergens to be tested. Copyright © 2017 AEDV. Publicado por Elsevier España, S.L.U. All rights reserved.

  4. The Effect of Neodymium: Yttrium Aluminum Garnet and Fractional Carbon Dioxide Lasers on Alopecia Areata: A Prospective Controlled Clinical Trial.

    PubMed

    Yalici-Armagan, Basak; Elcin, Gonca

    2016-04-01

    Effective treatment options for alopecia areata (AA) are missing. Whether lasers might be effective is a topic of debate. We aimed to evaluate whether neodymium: yttrium aluminum garnet (Nd:YAG) or fractional carbon dioxide lasers might stimulate the development of new hair. Thirty-two patients who had long-standing and treatment refractory diseases were recruited for the study. Three different patches on the scalp were selected, 1 of which served as control. The mean outcome measure was the hair count, which was calculated with the digital phototrichogram. Response was defined as at least 25% increase in the mean hair count at the treated patch compared with the control patch. At the end of the study, there was no statistically significant difference in the mean hair count for the 3 patches. In 7 of 32 patients (22%), an increase in the mean hair count was observed on the whole scalp including the control patch, which resulted in an improved Severity of Alopecia Tool (SALT) score. We have observed that Nd:YAG or fractional carbon dioxide lasers did not increase the mean hair count on the treated AA patches when compared with the control patch. However, an SALT score improvement in 22% of the patients suggested spontaneous remission.

  5. Contact dermatitis and patch testing for the allergist.

    PubMed

    Fonacier, Luz; Noor, Irum

    2018-06-01

    To review of contact dermatitis (CD) and its key allergens and provide updates and recommendations for the practicing allergist. Through the use of various scientific search engines (eg, PubMed and MEDLINE), we reviewed literature on CD, patch tests (PTs), key allergens, occupational dermatitis, and treatment. Studies on CD, important allergens, and PTs were considered. Contact-induced dermatitis may be due to allergic CD, irritant CD, systemic CD, contact urticaria, and protein CD. Key allergens include metals (nickel, gold), topical medicaments (topical corticosteroids), and cosmetics and personal care products (fragrances and preservatives such as methyl- and methylchloro-isothiazolinone). Present relevance of a positive PT result is the combination of definite, probable, and possible relevance and should be correlated with the patient's history and physical examination. Treatment of allergic CD includes identification of relevant allergens, patient education, avoidance, and provision of alternative products the patient can use. CD is a common inflammatory skin disease and should be suspected in patients presenting with acute, subacute, or chronic dermatitis. The gold standard for diagnosing allergic CD is a PT. This article provides practical recommendations for the diagnosis and management of CD commonly seen by the allergist in their practice. Copyright © 2018 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  6. Allergic contact dermatitis caused by acrylic-based medical dressings and adhesives.

    PubMed

    Mestach, Lien; Huygens, Sara; Goossens, An; Gilissen, Liesbeth

    2018-06-11

    Acrylates and methacrylates are acrylic resin monomers that are known to induce skin sensitization as a result of their presence in different materials, such as nail cosmetics, dental materials, printing inks, and adhesives. Allergic contact dermatitis resulting from the use of modern wound dressings containing them has only rarely been reported. To describe 2 patients who developed allergic contact dermatitis caused by acrylic-based modern medical dressings and/or adhesives. The medical charts of patients observed since 1990 were retrospectively reviewed for (meth)acrylate allergy resulting from contact with such materials, and their demographic characteristics and patch test results were analysed. Two patients were observed in 2014 and 2016 who had presented with positive patch test reactions to several acrylic-based dressings and/or adhesive materials, and to several (meth)acrylates, that is, hydroxyethyl acrylate, hydroxyethyl methacrylate, ethyleneglycol dimethacrylate, bisphenol A-glycidyl methacrylate/epoxy-acrylate, urethane diacrylate, and/or penta-erythritol acrylate. Allergic contact dermatitis needs to be considered in patients with eczematous reactions or delayed healing following the use of acrylic-based modern dressings or adhesives. However, identification of the culprit allergen is hampered by poor cooperation from the producers, so adequate labelling of medical devices is an urgent necessity. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Occupational Contact Dermatitis in North American Print Machine Operators Referred for Patch Testing: Retrospective Analysis of Cross-Sectional Data From the North American Contact Dermatitis Group 1998 to 2014.

    PubMed

    Warshaw, Erin M; Hagen, Solveig L; Belsito, Donald V; DeKoven, Joel G; Maibach, Howard I; Mathias, C G Toby; Zug, Kathryn A; Sasseville, Denis; Zirwas, Matthew J; Fowler, Joseph F; Fransway, Anthony F; DeLeo, Vincent A; Marks, James G; Pratt, Melanie D; Taylor, James S

    Little is known about the epidemiology of contact dermatitis (CD) in print machine operators (PMOs). The aims of this study were to estimate the prevalence of CD and characterize clinically relevant and occupationally related allergens among PMOs undergoing patch testing. This was a retrospective cross-sectional analysis of the North American Contact Dermatitis Group data from 1998 to 2014. Of 39,332 patch-tested patients, 132 (0.3%) were PMOs. Among PMOs, most were male (75.0%) and white (92.4%). The majority were printing press operators (85.6%). The most frequent sites of dermatitis were hands (63.6%), arms (29.5%), and face/scalp (24.2%). More than half had an occupationally related skin condition (56.1%). Final diagnoses were most commonly allergic CD (58.3%) and irritant CD (33.3%). Cobalt (20.8%), carba mix (12.5%), thiuram mix (8.3%), and formaldehyde (8.3%) were the most frequent occupationally related allergens. The top allergen sources included inks (22.9%), gloves (20.8%), and coatings/dye/copy/photographic chemicals (14.6%). Allergic CD, irritant CD, and involvement of exposed body areas were common among PMOs. Common allergens included rubber accelerators, metals, and preservatives.

  8. Contact dermatitis in saffron workers: clinical profile and identification of contact sensitizers in a saffron-cultivating area of Kashmir Valley of North India.

    PubMed

    Hassan, Iffat; Kamili, Afifa; Rasool, Farhan; Nehvi, Firdous; Rather, Parvaiz; Yasmin, Salwee; Pampori, Rafiq A; Jabeen, Yasmeen; Yaseen, Atiya; Bashir, Safia; Naaz, Saima

    2015-01-01

    Saffron, a bulbous perennial plant belonging to Iridaceae family, is the most expensive cultivated herb that is widely used for industrial and nonindustrial purposes. However, besides its attractive and valuable properties, contact dermatitis due to saffron is an uncommon reported entity. The aims of this study were to determine the clinical pattern patch-testing profile of contact dermatitis in saffron workers and to identify the most common allergens/sensitizers. One hundred ten saffron workers were patch-tested with 39 allergens, which included Indian standard series antigens, plant series antigens, and extracts from different parts of saffron flower. The allergens in Indian standard series accounted for 52.44% of positive reactions. Plant series and different parts of saffron accounted for 47.56% of the positive reactions. Among those patients with positive responses to the supplemental saffron allergens, 83.3% were of present or past relevance. The data observed in the present study confirm that the saffron dermatitis is a distinct clinical entity with characteristic clinical presentation and has a strong significance as an occupational allergen in those handling this plant. Patch testing with different parts of saffron flower has a role to play in finding out the etiological cause.

  9. Taro corms mucilage/HPMC based transdermal patch: an efficient device for delivery of diltiazem hydrochloride.

    PubMed

    Sarkar, Gunjan; Saha, Nayan Ranjan; Roy, Indranil; Bhattacharyya, Amartya; Bose, Madhura; Mishra, Roshnara; Rana, Dipak; Bhattacharjee, Debashis; Chattopadhyay, Dipankar

    2014-05-01

    The aim of this work is to examine the effectiveness of mucilage/hydroxypropylmethylcellulose (HPMC) based transdermal patch (matrix type) as a drug delivery device. We have successfully extracted mucilage from Colocasia esculenta (Taro) corms and prepared diltiazem hydrochloride incorporated mucilage/HPMC based transdermal patches using various wt% of mucilage by the solvent evaporation technique. Characterization of both mucilage and transdermal patches has been done by several techniques such as Molisch's test, organoleptic evaluation of mucilage, mechanical, morphological and thermal analysis of transdermal patches. Skin irritation test is studied on hairless Albino rat skin showing that transdermal patches are apparently free of potentially hazardous skin irritation. Fourier transform infrared analysis shows that there is no interaction between drug, mucilage and HPMC while scanning electron microscopy shows the surface morphology of transdermal patches. In vitro drug release time of mucilage-HPMC based transdermal patches is prolonged with increasing mucilage concentration in the formulation. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Topical ketoprofen TDS patch versus diclofenac gel: efficacy and tolerability in benign sport related soft‐tissue injuries

    PubMed Central

    Esparza, Francisco; Cobián, César; Jiménez, José Fernando; García‐Cota, Juan José; Sánchez, Carlos; SETRADE, Antonio Maestro and the working group for the acute pain study of

    2007-01-01

    Objective To compare the ketoprofen TDS patch with diclofenac gel in the treatment of traumatic acute pain in benign sport‐related soft‐tissue injuries. Design 7–14 treatment days, prospective, randomised, open study. Patients Outpatients aged 18–70 years diagnosed for painful benign sport‐related soft‐tissue injury (sprains, strains and contusions within the prior 48 h), randomised to either ketoprofen patch 100 mg once daily (n = 114) or diclofenac gel 2–4 g three times daily (n = 109). Intervention 7–14 days of topical non‐steroidal anti‐inflammatory drugs treatment to assess the pain intensity changes (daily activities and spontaneous at rest) in a daily diary (100‐mm Visual Analogue Scale (VAS)). Main outcome measurement Pain intensity (VAS). Results The ketoprofen patch was not inferior to diclofenac gel in reducing the baseline pain during daily activities (difference of –1.17 mm in favour of ketoprofen patch, 95% CI (–5.86 to 3.52), reducing to the baseline VAS 79%. Ketoprofen patch presented also a higher cure rate (64%) than diclofenac gel (46%) at day 7 (p = 0.004). Patient opinions about the treatment comfort (pharmaceutical shape, application and dosage) were also statistically higher for the ketoprofen patch (>80% of the patients rated as good or excellent the patch removal and skin adherence). Conclusion Ketoprofen patches are effective and safe pain relievers for the treatment of sports injury pain with advantages compared with diclofenac gel. PMID:17138642

  11. Tolerance to a Hair Dye Product Containing 2-Methoxymethyl-P-Phenylenediamine in an Ethnically Diverse Population of P-Phenylenediamine-Allergic Individuals.

    PubMed

    Zahir, Amir; Kindred, Chesahna; Blömeke, Brunhilde; Goebel, Carsten; Gaspari, Anthony A

    Allergic contact dermatitis after exposure to p-phenylenediamine (PPD)-containing hair dye products is a common and important clinical problem. Because there is a high rate of cross-elicitation of allergic contact dermatitis to other important hair dye products (such as p-toluene diamine and other aminophenol hair dyes) in PPD-allergic patients, safer alternative dyes with excellent hair coloring options are needed. This study aimed to study tolerance to Me-PPD in a PPD-allergic cohort. Twenty ethnically diverse volunteers with a history of contact dermatitis to hair dyes or other PPD-containing chemicals and positive patch test results to 1% PPD in petrolatum were recruited to study their immediate and delayed skin reactivity to PPD, vehicle control, and 2-methoxy-methyl-PPD (Me-PPD) using the allergy alert test (simulating hair dyeing conditions) on volar forearm skin. This test is a short-contact open patch test. The Me-PPD may offer a safer alternative for PPD-allergic patients with an absent or reduced elicitation response in the allergy alert test simulating hair dye use conditions. The absent or reduced response to Me-PPD diagnosed using the allergy alert test has been shown to help reduce the possibility of moderate to severe cross-elicitation reactions among consumers during hair dyeing.

  12. Contact sensitization to cosmetic series of allergens in a general population in Beijing.

    PubMed

    Zhao, Jian; Li, Lin-Feng

    2014-03-01

    Cosmetic allergic contact dermatitis (CACD) due to common cosmetic allergens in standard series has been extensively studied; however, the prevalence of contact allergy to other cosmetic allergens other than those in standard series is largely unknown. In this study, the frequency of contact sensitization to a European cosmetic series of allergens (Chemotechnique Diagnostics, Vellinge, Sweden) in healthy university student volunteers were detected in Beijing. Of 201 students studied, fifty-eight exhibited positive results, and 9 of them reported had cosmetics related dermatitis previously. The total positivity rate was not correlated to gender. The leading allergens were thimerosal (19.4%), shellac (3.0%), cocamidopropyl betaine (2.0%), hexamethylenetetramine (1.5%), dodecyl gallate (1.5%), hexahydro-1,3,5-tris-(2-hydroxyethyl)triazine (1.0%) and methyldibromo glutaronitrile (1.0%). The positivity rate of thimerosal patch test in men (9.8%) was lower than that of women (23.6%, P < 0.05, Chi square test), but no difference could be found between the prevalence of other cosmetic allergens in men and women (P > 0.05, Chi square test). These results suggested that some cosmetic-related contact allergies may be missed by just testing patients with the European standard series or T.R.U.E. test system only, we recommend shellac, cocamidopropyl betaine, hexamethylenetetramine and dodecyl gallate as the additionally candidates for patch testing in patients with suspected CACD. © 2014 Wiley Periodicals, Inc.

  13. Food-Related Contact Dermatitis, Contact Urticaria, and Atopy Patch Test with Food.

    PubMed

    Walter, Alexandra; Seegräber, Marlene; Wollenberg, Andreas

    2018-06-07

    A wide variety of foods may cause or aggravate skin diseases such as contact dermatitis, contact urticaria, or atopic dermatitis (AD), both in occupational and private settings. The mechanism of action underlying allergic disease to food, food additives, and spices may be immunologic and non-immunologic. The classification and understanding of these reactions is a complex field, and knowledge of the possible reaction patterns and appropriate diagnostic test methods is essential. In addition, certain foods may cause worsening of atopic dermatitis lesions in children. The atopy patch test (APT) is a well-established, clinically useful tool for assessing delayed type reactions to protein allergens in patients and may be useful to detect protein allergens relevant for certain skin diseases. The APT may even detect sensitization against allergens in intrinsic atopic dermatitis patients, who show negative skin prick test and negative in vitro IgE test results against these allergens. Native foods, SPT solutions on filter paper, and purified allergens in petrolatum have been used for APT. The European Task Force on Atopic Dermatitis (ETFAD) has worked on standardizing this test in the context of AD patients, who are allergic to aeroallergens and food. This recommended, standardized technique involves test application at the upper back of children and adults; use of large, 12-mm Finn chambers; avoidance of any pre-treatment such as tape stripping or delipidation; standardized amounts of purified allergens in petrolatum; and use of the standardized ETFAD reading key. The APT may not be the best working or best standardized of all possible skin tests, but it is the best test that we currently have available in this niche.

  14. Endovascular Patch Embolization for Blood Blister-Like Aneurysms in Dorsal Segment of Internal Carotid Artery.

    PubMed

    Hao, Xudong; Li, Guilin; Ren, Jian; Li, Jingwei; He, Chuan; Zhang, Hong-Qi

    2018-05-01

    Blood blister-like aneurysms (BBAs) in the dorsal segment of the internal carotid artery are fragile and difficult to treat, and the optimal treatment for BBAs is still controversial. We report clinical and angiographic results with procedural details for the treatment of BBA by using the endovascular patch embolization method. We retrospectively reviewed patients who presented with subarachnoid hemorrhage caused by internal carotid artery-BBAs and were treated with the endovascular patch embolization method in our center from October 2011 to March 2015. Clinical records, angiographic findings, procedural details, and follow-up results are reported in this study. Eight patients were enrolled in this study. All patients were treated with the endovascular patch embolization method. The key points of this method are step-by-step stent deployment and swaying of the microcatheter to coil the aneurysm sac and the wedge-shaped space between the stent and parent artery and, thereby, in the aneurysm sac and parent artery around the aneurysm neck. When the stent is completely deployed, an endovascular patch is formed and anchored around the neck of the BBA. The procedure was successful in all cases. No acute complications developed in any case. No rerupture or recurrence of the BBA occurred during follow-up. One patient with Hunt-Hess V subarachnoid hemorrhage died of multiple organ failure 4 months post treatment. Another patient died of intracranial infection related to the ventricle-peritoneal shunt. The remaining 6 patients had good clinical outcomes (modified Rankin Scale score of zero). Endovascular patch embolization is an improvement on stent-assisted coil embolization, which could be successfully performed only with extensive skill and patience. Endovascular patch embolization could be an effective method in BBA treatment. However, its efficacy and safety should be verified in a larger patient cohort and long-term follow-up study. Copyright © 2018. Published by Elsevier Inc.

  15. Consultation or corruption? The ethics of signing on to the medical-industrial complex.

    PubMed

    Jones, James W; McCullough, Laurence B; Richman, Bruce W

    2006-01-01

    A prominent vascular surgeon is approached by a representative of a large medical device company with a proposal to implant a new self-sealing patch for closing open carotid endarterectomies. The patch is made of a new synthetic material that establishes immediate hemostasis and inhibits restenosis in animal studies. It has just been approved for human use by the Food and Drug Administration. The cost of the new patch is much higher than for established comparable products, even when potential long-term benefits are considered, but using it would reduce the operative time required for achieving hemostasis. The manufacturer's representative tells you that the company will pay a selected group of vascular surgeons $500 apiece each time they insert the patch on their patients and complete a one-page report. Surgeons with the highest volume of cases utilizing the patch will be offered a paid clinical consultancy with the company. You've used another company's product for several years and found it entirely satisfactory, but have followed development of the new patch with interest and considered trying it in your patients having carotid endarterectomies. What should you do? A. Join the study. You probably would have used the new patch on your patients anyway. B. If the early data warrant, implant the patch on a trial basis without enrolling in the project, and finally decide whether to continue using it based on your clinical experience and additional published reports. C. Call some of the other investigators who have already enrolled in the project and ask them about their experience. D. Decline the invitation immediately. Refuse to ever speak to the representative again. E. Estimate the ability of your patients to sustain the high cost of the new product and decide accordingly whether to use it.

  16. Multi-atlas-based CT synthesis from conventional MRI with patch-based refinement for MRI-based radiotherapy planning

    NASA Astrophysics Data System (ADS)

    Lee, Junghoon; Carass, Aaron; Jog, Amod; Zhao, Can; Prince, Jerry L.

    2017-02-01

    Accurate CT synthesis, sometimes called electron density estimation, from MRI is crucial for successful MRI-based radiotherapy planning and dose computation. Existing CT synthesis methods are able to synthesize normal tissues but are unable to accurately synthesize abnormal tissues (i.e., tumor), thus providing a suboptimal solution. We propose a multiatlas- based hybrid synthesis approach that combines multi-atlas registration and patch-based synthesis to accurately synthesize both normal and abnormal tissues. Multi-parametric atlas MR images are registered to the target MR images by multi-channel deformable registration, from which the atlas CT images are deformed and fused by locally-weighted averaging using a structural similarity measure (SSIM). Synthetic MR images are also computed from the registered atlas MRIs by using the same weights used for the CT synthesis; these are compared to the target patient MRIs allowing for the assessment of the CT synthesis fidelity. Poor synthesis regions are automatically detected based on the fidelity measure and refined by a patch-based synthesis. The proposed approach was tested on brain cancer patient data, and showed a noticeable improvement for the tumor region.

  17. Pseudo CT estimation from MRI using patch-based random forest

    NASA Astrophysics Data System (ADS)

    Yang, Xiaofeng; Lei, Yang; Shu, Hui-Kuo; Rossi, Peter; Mao, Hui; Shim, Hyunsuk; Curran, Walter J.; Liu, Tian

    2017-02-01

    Recently, MR simulators gain popularity because of unnecessary radiation exposure of CT simulators being used in radiation therapy planning. We propose a method for pseudo CT estimation from MR images based on a patch-based random forest. Patient-specific anatomical features are extracted from the aligned training images and adopted as signatures for each voxel. The most robust and informative features are identified using feature selection to train the random forest. The well-trained random forest is used to predict the pseudo CT of a new patient. This prediction technique was tested with human brain images and the prediction accuracy was assessed using the original CT images. Peak signal-to-noise ratio (PSNR) and feature similarity (FSIM) indexes were used to quantify the differences between the pseudo and original CT images. The experimental results showed the proposed method could accurately generate pseudo CT images from MR images. In summary, we have developed a new pseudo CT prediction method based on patch-based random forest, demonstrated its clinical feasibility, and validated its prediction accuracy. This pseudo CT prediction technique could be a useful tool for MRI-based radiation treatment planning and attenuation correction in a PET/MRI scanner.

  18. Multi-atlas-based CT synthesis from conventional MRI with patch-based refinement for MRI-based radiotherapy planning.

    PubMed

    Lee, Junghoon; Carass, Aaron; Jog, Amod; Zhao, Can; Prince, Jerry L

    2017-02-01

    Accurate CT synthesis, sometimes called electron density estimation, from MRI is crucial for successful MRI-based radiotherapy planning and dose computation. Existing CT synthesis methods are able to synthesize normal tissues but are unable to accurately synthesize abnormal tissues (i.e., tumor), thus providing a suboptimal solution. We propose a multi-atlas-based hybrid synthesis approach that combines multi-atlas registration and patch-based synthesis to accurately synthesize both normal and abnormal tissues. Multi-parametric atlas MR images are registered to the target MR images by multi-channel deformable registration, from which the atlas CT images are deformed and fused by locally-weighted averaging using a structural similarity measure (SSIM). Synthetic MR images are also computed from the registered atlas MRIs by using the same weights used for the CT synthesis; these are compared to the target patient MRIs allowing for the assessment of the CT synthesis fidelity. Poor synthesis regions are automatically detected based on the fidelity measure and refined by a patch-based synthesis. The proposed approach was tested on brain cancer patient data, and showed a noticeable improvement for the tumor region.

  19. Clinical Characteristics of Connective Tissue Nevi in Tuberous Sclerosis Complex With Special Emphasis on Shagreen Patches.

    PubMed

    Bongiorno, Michelle A; Nathan, Neera; Oyerinde, Oyetewa; Wang, Ji-An; Lee, Chyi-Chia Richard; Brown, G Thomas; Moss, Joel; Darling, Thomas N

    2017-07-01

    Patients with tuberous sclerosis complex (TSC) frequently develop collagenous connective tissue nevi. The prototypical lesion is a large shagreen patch located on the lower back, but some patients only manifest small collagenomas or have lesions elsewhere on the body. The ability to recognize these variable presentations can be important for the diagnosis of TSC. To describe the clinical characteristics of connective tissue nevi on the trunk and extremities of patients with tuberous sclerosis complex. A retrospective analysis of patient medical records and skin photography was performed; 104 adult patients with TSC were enrolled in an observational cohort study that was enriched for those with pulmonary lymphangioleiomyomatosis, and was therefore composed mostly of women (99 women, 5 men). All patients included were examined at the National Institutes of Health (NIH) in Bethesda, Maryland, from 1998 to 2013. Connective tissue nevi were categorized per anatomic location and size. Lesions less than 1 cm in diameter were termed collagenomas. Shagreen patches were characterized as small (1 to <4 cm), medium (4 to <8 cm), and large (≥8 cm). Frequency, anatomic location, size, and histological appearance of connective tissue nevi in patients with TSC. Overall, 58 of 104 patients (median [range] age, 42 [19-70] years) with TSC (56%) had at least 1 connective tissue nevus on the trunk or thighs; of these, 28 of 58 patients (48%) had a solitary lesion, and 30 of 58 patients (52%) had 2 or more lesions. Overall, 120 lesions from 55 patients were classified by size; 46 lesions (38%) were collagenomas; 39 lesions (32%) were small shagreen patches; 21 lesions (18%), medium shagreen patches; and 14 lesions (12%), large shagreen patches. The distribution of lesions was 9% (n = 11), upper back; 29% (n = 35), middle back; 51% (n = 61), lower back; and 11% (n = 13), other locations. All 26 shagreen patches that were analyzed histopathologically had coarse collagen fibers and 24 of 26 stained with Miller elastic stain had decreased elastic fibers. On immunoblot analysis, fibroblasts grown from shagreen patches expressed higher levels of phosphorylated ribosomal protein S6 than paired fibroblasts from normal-appearing skin. Tuberous sclerosis complex-related connective tissue nevi are not limited to the lower back, and occasionally present on the central or upper back, buttocks, or thighs. Elastic fibers are typically decreased. Recognition of these variable presentations can be important for TSC diagnosis.

  20. The Usefulness of Patch Repair Using the Repermeabilized Umbilical Vein of the Round Ligament for Hepatobiliary Malignancies.

    PubMed

    Takahashi, Michiro; Saiura, Akio; Takahashi, Yu

    2017-11-01

    Patients with tumors invading major veins may require combined resection and reconstruction. However, venous reconstruction often demands complex hepatobiliary and vascular surgical procedures. In this study, we report a simple patch repair technique for venous reconstruction using the repermeabilized umbilical vein of the round ligament. We reviewed the outcomes of eleven patients who underwent venous wedge resection and patch repair using the repermeabilized umbilical vein of the round ligament at our institution. Procurement of the round ligament and method of making a patch is simple. The duration of anastomosis was approximately 15 min. Eight patients (73%) underwent hepatic resection followed by hepatic vein reconstruction; two (18%) pancreaticoduodenectomy followed by inferior vena cava (IVC) reconstruction; one (9%) hepatic resection followed by IVC reconstruction. Although one reconstructed vein became narrowed, the other ten veins were patent after surgery. Patch repair using the repermeabilized umbilical vein of the round ligament is a simple and useful technique.

  1. Smoking cessation during alcohol treatment: a randomized trial of combination nicotine patch plus nicotine gum.

    PubMed

    Cooney, Ned L; Cooney, Judith L; Perry, Bridget L; Carbone, Michael; Cohen, Emily H; Steinberg, Howard R; Pilkey, David T; Sevarino, Kevin; Oncken, Cheryl A; Litt, Mark D

    2009-09-01

    The primary aim was to compare the efficacy of smoking cessation treatment using a combination of active nicotine patch plus active nicotine gum versus therapy consisting of active nicotine patch plus placebo gum in a sample of alcohol-dependent tobacco smokers in an early phase of out-patient alcohol treatment. A secondary aim was to determine whether or not there were any carry-over effects of combination nicotine replacement on drinking outcomes. Small-scale randomized double-blind placebo-controlled clinical trial with 1-year smoking and drinking outcome assessment. Two out-patient substance abuse clinics provided a treatment platform of behavioral alcohol and smoking treatment delivered in 3 months of weekly sessions followed by three monthly booster sessions. Participants were 96 men and women with a diagnosis of alcohol abuse or dependence and smoking 15 or more cigarettes per day. All participants received open-label transdermal nicotine patches and were randomized to receive either 2 mg nicotine gum or placebo gum under double-blind conditions. Analysis of 1-year follow-up data revealed that patients receiving nicotine patch plus active gum had better smoking outcomes than those receiving patch plus placebo gum on measures of time to smoking relapse and prolonged abstinence at 12 months. Alcohol outcomes were not significantly different across medication conditions. Results of this study were consistent with results of larger trials of smokers without alcohol problems, showing that combination therapy (nicotine patch plus gum) is more effective than monotherapy (nicotine patch) for smoking cessation.

  2. Treating smokers before the quit date: can nicotine patches and denicotinized cigarettes reduce cravings?

    PubMed

    Rezaishiraz, Hamed; Hyland, Andrew; Mahoney, Martin C; O'Connor, Richard J; Cummings, K Michael

    2007-11-01

    The present study investigated whether treatment with the combination of denicotinized cigarettes and 21-mg nicotine patch for 2 weeks before a designated quit date could lessen cravings for smoking, thereby helping smokers abstain from smoking. The study was a randomized controlled clinical trial conducted at Roswell Park Cancer Institute, Buffalo, New York, in 2004 and 2005. Patients included 98 adult heavy smokers (using 20 or more cigarettes/day). Half of the subjects received 2 weeks of combination of denicotinized cigarettes (Quest 3) and 21-mg nicotine patch for 2 weeks before the quit date. The remaining smokers were switched to light cigarettes (Quest 1) during the 2 weeks before the quit date. After the quit date, all subjects received counseling for smoking cessation and were provided nicotine patches for up to 8 weeks after the quit date. Self-reported cravings for smoking, withdrawal symptoms, and smoking abstinence were measured at predetermined intervals using phone-based surveys and in clinical visits. The group that used denicotinized cigarettes and nicotine patch before quitting reported less frequent and less intense cravings for cigarettes in the 2 weeks before and after the designated quit date. Self-reported withdrawal symptoms and quit rates did not differ significantly between the groups. The use of a denicotinized cigarette combined with the nicotine patch appears to lessen cravings to smoke in the immediate postcessation period. A larger, better-powered study is needed to test if this treatment combination has merit for increasing quit rates.

  3. The prevalence of positive reactions in the atopy patch test with aeroallergens and food allergens in subjects with atopic eczema: a European multicenter study.

    PubMed

    Darsow, U; Laifaoui, J; Kerschenlohr, K; Wollenberg, A; Przybilla, B; Wüthrich, B; Borelli, S; Giusti, F; Seidenari, S; Drzimalla, K; Simon, D; Disch, R; Borelli, S; Devillers, A C A; Oranje, A P; De Raeve, L; Hachem, J-P; Dangoisse, C; Blondeel, A; Song, M; Breuer, K; Wulf, A; Werfel, T; Roul, S; Taieb, A; Bolhaar, S; Bruijnzeel-Koomen, C; Brönnimann, M; Braathen, L R; Didierlaurent, A; André, C; Ring, J

    2004-12-01

    The atopy patch test (APT) was proposed to evaluate IgE-mediated sensitizations in patients with atopic eczema (AE). The prevalence and agreement with clinical history and specific IgE (sIgE) of positive APT reactions was investigated in six European countries using a standardized method. A total of 314 patients with AE in remission were tested in 12 study centers on clinically uninvolved, non-abraded back skin with 200 index of reactivity (IR)/g of house dust mite Dermatophagoides pteronyssinus, cat dander, grass, and birch pollen allergen extracts with defined major allergen contents in petrolatum. Extracts of egg white, celery and wheat flour with defined protein content were also patch tested. APT values were evaluated at 24, 48, and 72 h according to the European Task Force on Atopic Dermatitis (ETFAD) guidelines. In addition, skin-prick test (SPT) and sIgE and a detailed history on allergen-induced eczema flares were obtained. Previous eczema flares, after contact with specific allergens, were reported in 1% (celery) to 34% (D. pteronyssinus) of patients. The frequency of clear-cut positive APT reactions ranged from 39% with D. pteronyssinus to 9% with celery. All ETFAD intensities occured after 48 and 72 h. Positive SPT (16-57%) and elevated sIgE (19-59%) results were more frequent. Clear-cut positive APT with all SPT and sIgE testing negative was seen in 7% of the patients, whereas a positive APT without SPT or sIgE for the respective allergen was seen in 17% of the patients. APT, SPT and sIgE results showed significant agreement with history for grass pollen and egg white (two-sided Pr > /Z/ < or = 0.01). In addition, SPT and sIgE showed significant agreement with history for the other aeroallergens. With regard to clinical history, the APT had a higher specificity (64-91% depending on the allergen) than SPT (50-85%) or sIgE (52-85%). Positive APT were associated with longer duration of eczema flares and showed regional differences. In 10 non-atopic controls, no positive APT reaction was seen. Aeroallergens and food allergens are able to elicit eczematous skin reactions after epicutaneous application. As no gold standard for aeroallergen provocation in AE exists, the relevance of aeroallergens for AE flares may be evaluated by APT in addition to SPT and sIgE. The data may contribute to the international standardization of the APT.

  4. Evaluating high-dose rivastigmine patch in severe Alzheimer's disease: analyses with concomitant memantine usage as a factor.

    PubMed

    Grossberg, George T; Farlow, Martin R; Meng, Xiangyi; Velting, Drew M

    2015-01-01

    ACTION, a 24-week, prospective, randomized, parallel-group, double-blind study in patients with severe Alzheimer's disease (AD), demonstrated significant efficacy of 13.3 mg/24 h versus 4.6 mg/24 h rivastigmine patch on the Severe Impairment Battery (SIB) and Alzheimer's Disease Cooperative Study-Activities of Daily Living scale-Severe Impairment Version (ADCS-ADL-SIV). Overall, 61% of the study population received at least 1 dose of concomitant memantine, regardless of dose or duration. This retrospective analysis investigated the effects of concomitant memantine on the efficacy, safety and tolerability of 13.3 mg/24 h versus 4.6 mg/24 h rivastigmine patch. Patients were stratified according to whether or not they received at least one dose of concomitant memantine during the double-blind phase. Changes from baseline on the SIB and ADCS-ADL-SIV were compared using analysis of covariance (ANCOVA) with treatment, pooled center, memantine usage and treatment-by-memantine as factors, and baseline as a covariate. Safety and tolerability were assessed. Memantine-treated patients were younger than those not receiving memantine (mean 75.9 and 78.8 years, respectively), with a lower screening Mini-Mental State Examination (8.6 and 9.2, respectively). ANCOVA confirmed there was no significant interaction (p>0.1) between study treatment and memantine use on the SIB or ADCS-ADL-SIV. The incidence of adverse events was: 71.4%, 13.3 mg/24 h patch with memantine; 79.7%, 13.3 mg/24 h patch alone; 74.7%, 4.6 mg/24 h patch with memantine; and 71.1%, 4.6 mg/24 h patch alone. These data suggest benefit of 13.3 mg/24 h versus 4.6 mg/24 h rivastigmine patch, regardless of concomitant memantine use. The incidence of adverse events with highdose patch was similar in memantine-treated patients and those not receiving memantine.

  5. Clinical profile and quality of life of patients with occupational contact dermatitis from New Delhi, India.

    PubMed

    Bhatia, Riti; Sharma, Vinod K; Ramam, M; Sethuraman, Gomathy; Yadav, Chander P

    2015-09-01

    Data regarding occupational contact dermatitis (OCD) and its effect on quality of life (QOL) in India are limited. To evaluate patients with OCD and record the outcome of treatment. All patients with OCD were evaluated for severity of disease (by the use of physician global assessment) and its effect on QOL (by use of the Dermatology Life Quality Index) questionnaire) at the first visit and after 3 months of treatment. Among 117 patients with OCD, hand eczema was present in 81.2%. Positive patch test reactions were found in 76%. The most common allergens were Parthenium hysterophorus and potassium dichromate. The most frequent diagnosis was occupational allergic contact dermatitis (OACD) (57%), caused by farming and construction work, followed by occupational irritant contact dermatitis (OICD) (24%), caused by wet work. Severe psychosocial distress was recorded in 62.5% of patients. After 3 months of treatment, 83% improved significantly, and 54% had improvement in QOL. Farmers were most frequently affected, followed by construction workers and housewives. OACD was found at a higher frequency than OICD. The most frequent allergens were Parthenium hysterophorus in farmers, potassium dichromate in construction workers, and vegetables in housewives. OCD has a significant impact on QOL. Patch testing, in addition to standard treatment, improves the outcome considerably. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Occupational contact dermatitis caused by 1,3-benzenedimethanamine, N-(2-phenylethyl) derivatives in hardeners for epoxy paints and coatings.

    PubMed

    Pesonen, Maria; Kuuliala, Outi; Suomela, Sari; Aalto-Korte, Kristiina

    2016-12-01

    Amines in epoxy hardeners are significant causes of occupational allergic contact dermatitis among workers who use epoxy resin systems. To describe a novel group of contact allergens: N-(2-phenylethyl) derivatives of the reactive amine 1,3-benzenedimethanamine (1,3-BDMA). We describe the clinical examinations and exposure of 6 patients with occupational contact allergy to derivatives of 1,3-BDMA. Of the 6 patients, 4 were spray painters who used epoxy paints, 1 was a floor layer who handled a variety of epoxy coatings, and 1 was a worker in epoxy hardener manufacture. We were able to confirm exposure to epoxy hardeners that contained derivatives of 1,3-BDMA in 5 of the 6 sensitized patients. Despite the close structural resemblance between derivatives of 1,3-BDMA and m-xylylenediamine (MXDA), only 3 patients reacted positively to MXDA. Concomitant contact allergy to diglycidyl ether of bisphenol A resin was seen in 2 of the 6 patients. Because of the lack of a commercially available patch test substance, the diagnosis of contact allergy to derivatives of 1,3-BDMA requires patch testing with either the epoxy hardener product or a hardener ingredient that contains the derivatives of 1,3-BDMA. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Natural orifice transluminal endoscopic surgery for patients with perforated peptic ulcer.

    PubMed

    Bonin, Eduardo A; Moran, Erica; Gostout, Christopher J; McConico, Andrea L; Zielinski, Martin; Bingener, Juliane

    2012-06-01

    Perforation accounts for 70% of deaths attributed to peptic ulcers. Laparoscopic repair is effective but infrequently used. Our aim was to assess how many patients with perforated peptic ulcer could be candidates for a transluminal endoscopic omental patch closure. This retrospective study reviewed patients with perforated peptic ulcer from 2005 to 2010. Demographics, ulcer characteristics, operative procedure, and outcomes were recorded. Candidates for endoscopic transluminal repair were defined as those having undergone omental patch closure of an ulcer of appropriate size and no contraindications to laparoscopy or endoscopy. In the retrospective review, a total of 104 patients were identified; 62% female, mean age = 68 years, mean ASA of 3, and 63% medication-related ulcers. Fifty-nine (63%) had an omental patch (80% open), and 35 (37%) had other procedures. Ten patients had nonoperative management. Thirty-day mortality was 14% and 1 year mortality was 35%. Forty-nine patients (52%) were considered potential candidates for transluminal repair. Sixty-three percent of our patients sustained a medication-related perforation with 1 year mortality of 35%. The majority of patients were treated using open omental patch repair. Transluminal endoscopic repair may provide an additional situation for a minimally invasive approach for a number of these patients.

  8. A comparative multicenter study of two transdermal estradiol replacement therapies in the treatment of postmenopausal symptoms.

    PubMed

    Van Leusden, H A; Albertyn, G; Verlaine, C; Van Ruymbeke, J

    1993-01-01

    Comparison of the effects of treatment of two transdermal therapeutic systems for estrogen replacement therapy with regard to efficacy, tolerability, and acceptance. Open randomized. Multicenter. A study population of 104 postmenopausal women was randomized on a 1:1 basis to treatment with one of two estradiol patches, System (Cilag) and Estraderm (Ciba-Geigy). Systolic and diastolic BP, hot flushes, night sweating, fatigue, insomnia, depression, nervousness, headache, vaginal discomfort (efficacy variables); bleeding, dermatological symptoms, comfort and adhesiveness of patch, and other possible causes of discontinuation (tolerability); general evaluation by patient (acceptance). Considering all efficacy variables, 53% of Systen and 46% of Estraderm patients found the therapy satisfactory. Tolerability was somewhat higher in the Systen group. Adhesiveness of the patch was significantly better for Systen. Overall, 79% of Systen patients and 62% of Estraderm patients evaluated treatment as "good" or "very good." The majority of patients in both groups found the patch very comfortable or only slightly obtrusive.

  9. Patch testing with a new fragrance mix - reactivity to the individual constituents and chemical detection in relevant cosmetic products.

    PubMed

    Frosch, Peter J; Rastogi, Suresh C; Pirker, Claudia; Brinkmeier, Thomas; Andersen, Klaus E; Bruze, Magnus; Svedman, Cecilia; Goossens, An; White, Ian R; Uter, Wolfgang; Arnau, Elena Giménez; Lepoittevin, Jean-Pierre; Johansen, Jeanne Duus; Menne, Torkil

    2005-04-01

    A new fragrance mix (FM II), with 6 frequently used chemicals not present in the currently used fragrance mix (FM I), was evaluated in 6 dermatological centres in Europe, as previously reported. In this publication, test results with the individual constituents and after repeated open application test (ROAT) of FM II are described. Furthermore, cosmetic products which had caused a contact dermatitis in patients were analysed for the presence of the individual constituents. In 1701 patients, the individual constituents of the medium (14%) and the highest (28%) concentration of FM II were simultaneously applied with the new mix at 3 concentrations (break-down testing for the lowest concentration of FM II (2.8%) was performed only if the mix was positive). ROAT was performed with the concentration of the FM II which had produced a positive or doubtful (+ or ?+) patch test reaction. Patients' products were analysed for the 6 target compounds by gas chromatography-mass spectrometry (GC-MS). 50 patients (2.9%) showed a positive reaction to 14% FM II and 70 patients (4.1%) to 28% FM II. 24/50 (48%) produced a positive reaction to 1 or more of the individual constituents of 14% FM II and 38/70 (54.3%) to 28% FM II, respectively. If doubtful reactions to individual constituents are included, the break-down testing was positive in 74% and 70%, respectively. Patients with a positive reaction to 14% FM II showed a higher rate of reactions to the individual constituent of the 28% FM II: 36/50 (72%). Positive reactions to individual constituents in patients negative to FM II were exceedingly rare. If doubtful reactions are regarded as negative, the sensitivity, specificity, positive predictive value and negative predictive value for the medium concentration of FM II towards at least 1 individual constituent was 92.3% (exact 95% confidence interval 74.9-99.1%), 98.4% (97.7-99.0%), 48% (33.7-62.6%) and 99.9% (99.6-"100.0%), respectively. For the high concentration, the figures were very similar. The frequency of positive reactions to the individual constituents in descending order was the same for both FM II concentrations: hydroxyisohexyl 3-cyclohexene carboxaldehyde (Lyral) > citral > farnesol > citronellol > alpha-hexyl-cinnamic aldehyde (AHCA). No unequivocally positive reaction to coumarin was observed. Lyral) was the dominant individual constituent, with positive reactions in 36% of patients reacting to 14% FM II and 37.1% to 28% FM II. 5/11 patients developed a positive ROAT after a median of 7 days (range 2-10). The 5 patients with a doubtful or negative reaction to 28% FM II were all ROAT negative except 1. There were 7 patients with a certain fragrance history and a positive reaction to either 28% or 14% FM II but a negative reaction to FM I. Analysis with GC-MS in a total of 24 products obtained from 12 patients showed at least 1-5 individual constituents per product: Lyral (79.2%), citronellol (87.5%), AHCA (58.3%), citral (50%) and coumarin (50%). The patients were patch test positive to Lyral, citral and AHCA. In conclusion, patients with a certain fragrance history and a negative reaction to FM I can be identified by FM II. Testing with individual constituents is positive in about 50% of cases reacting to either 14% or 28% FM II.

  10. Cancer Seeding Risk from an Epidural Blood Patch in Patients with Leukemia or Lymphoma.

    PubMed

    Demaree, Christopher J; Soliz, Jose M; Gebhardt, Rodolfo

    2017-04-01

    Lumber punctures are a common procedure in patients with cancer. However, a potential complication of a lumbar puncture is a postdural puncture headache. The risk of neoplastic seeding to the central nervous system has led to concern over performing epidural blood patches (EBPs) for the treatment of postdural puncture headaches in patients with cancer. The goal of this retrospective study was to evaluate cancer seeding in the central nervous system in patients diagnosed with leukemia or lymphoma. Institutional electronic records were queried over a 13-year period from 2000 to 2013 for patients with leukemia and/or lymphoma and who received at least one EBP. Demographic and procedural data, cancer treatments, and mortality were all examined. Patient records were reviewed for evidence of new-onset neoplastic central nervous system seeding after an epidural blood patch. A total of 80 patients were identified for review. Eighteen patients had a diagnosis of leukemia, and 62 had lymphoma. Following an EBP, none of the patients experienced new cancer or cancer seeding in the central nervous system following an epidural blood patch at a median follow-up of 3.74 years. Though the risks of EBP in the cancer patient population have been hypothesized, no previous studies have assessed the risk of seeding cancer to the central nervous system. Based on our results, an epidural blood patch bears low risk of cancer seeding when used to treat postdural puncture headache that is unresponsive to conservative treatments. © 2016 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  11. Anterior Leaflet Augmentation With CorMatrix Porcine Extracellular Matrix in Twenty-Five Patients: Unexpected Patch Failures and Histologic Analysis.

    PubMed

    Kelley, Thomas M; Kashem, Mohammed; Wang, He; McCarthy, James; Carroll, Nels D; Moser, G William; Guy, T Sloane

    2017-01-01

    This study reported on the treatment of Carpentier type IIIa and type IIIb mitral regurgitation (MR) with a large patch anterior mitral valve leaflet augmentation technique using CorMatrix (CorMatrix Cardiovascular Inc, Alpharetta, GA) extracellular matrix (ECM). A single-site chart review was conducted on patients who underwent anterior leaflet augmentation performed with the Da Vinci surgical robot (Intuitive Surgical, Sunnyvale, CA) or through a median sternotomy. Only patients who had anterior leaflet augmentation with porcine intestine ECM or autologous pericardium were included. Follow-up echocardiography was performed on all patients. Histologic specimens were available on ECM patches from a subset of patients who required reoperation. Between August 2011 and April 2014, 44 patients (mean age, 62.6 ± 12.2 years) underwent anterior leaflet augmentation with either porcine intestinal ECM or autologous pericardium at the Temple University Hospital in Philadelphia. Two (4%) late deaths occurred, one in each group. One patient who underwent ECM augmentation died of non-cardiac-related causes 7 months after discharge as a result of complications of chronic renal failure. The second late death occurred 5 months after discharge because of complications of a stroke in a patient in the pericardial augmentation group. Eight (32%) of the patients with ECM had recurrence of severe MR on echocardiography at an average time of 201 ± 98 days. Seven (28%) patients required reoperation because of failure of the ECM patch including perforation (4%), excessive patch dilation (20%), and suture line dehiscence (4%). In contrast, none of the patients with pericardial augmentation developed severe MR or required operation. Statistical analysis of the patients with ECM augmentation demonstrated no correlation of the following: age; sex; comorbid conditions such as diabetes, chronic obstructive pulmonary disease, and hypertension; left ventricular ejection fraction; surgical approach; annuloplasty size; or type of MR with patch failure. A lower body mass index was the only factor associated with recurrent severe regurgitation on univariate analysis (p = 0.039). Histologic study of the four available explants demonstrated intense inflammation without evidence of host integration. The remaining 15 (60%) patients had normal mitral leaflet structure and function on follow-up echocardiograms out to 12 months. For type III MR, a large anterior leaflet patch technique with porcine ECM was associated with a 32% recurrence rate of severe MR related directly to patch failure. Further research and development should be performed on the use of ECM materials with a goal to decrease the failure rate experienced in this study. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  12. Pharmacokinetics of a novel transdermal rivastigmine patch for the treatment of Alzheimer’s disease: a review

    PubMed Central

    Kurz, A; Farlow, M; Lefèvre, G

    2009-01-01

    Background: Cholinesterase inhibitors have all been available in oral formulations, but a rivastigmine transdermal patch has now been developed and is approved in many countries worldwide for the treatment of mild-to-moderate Alzheimer’s disease (AD) (including the USA, Latin America, Europe and Asia). Objectives: To review the available pharmacokinetic data that supported the rationale behind the development of the rivastigmine transdermal patch and its clinical effects in dementia therapy. This article will also discuss how the patch may alter the treatment paradigm for patients with AD. Results: The 9.5 mg/24 h rivastigmine patch was shown to provide comparable exposure to the highest recommended doses of capsules (12 mg/day) with significantly lower maximum plasma concentration (Cmax 8.7 vs. 21.6 ng/ml) and slower absorption rate (tmax 8.1 vs. 1.4 h). In a clinical trial of 1195 AD patients, this translated into similar efficacy with three times fewer reports of nausea and vomiting (7.2% vs. 23.1%, and 6.2% vs. 17.0% respectively). Consequently, more patients in the 9.5 mg/24 h patch group achieved their target therapeutic dose at the end of the study, compared with those in the 12 mg/day capsule group (95.9% vs. 64.4%). Conclusion: The rivastigmine patch provides continuous drug delivery over 24 h and similar efficacy to the highest recommended dose of oral rivastigmine with improved tolerability. This may allow patients to achieve optimal therapeutic doses and to benefit from a longer duration of treatment. PMID:19392927

  13. Transdermal nitroglycerin as an adjuvant to patient-controlled morphine analgesia after total knee arthroplasty

    PubMed Central

    Orbach-Zinger, Sharon; Lenchinsky, Artium; Paul-Kesslin, Lesley; Velks, Steven; Salai, Moses; Eidelman, Leonid A

    2009-01-01

    BACKGROUND: Nitroglycerin (NTG) has been shown to be a useful adjunct for pain treatment without increasing adverse side effects. The effects of NTG on postoperative morphine consumption after knee replacement were evaluated. METHODS: After undergoing total knee replacement, patients receiving patient-controlled morphine analgesia were randomly assigned to receive either an NTG or a placebo patch. The blinded investigator assessed each patient using a visual analogue scale at rest and while moving, as well as the patient’s morphine requirements, sedation score, sleep quality, nausea and vomiting, vital signs and postoperative bleeding. RESULTS: Two of the patients in the NTG group suffered postoperative myocardial infarctions after removal of the patch. Because of these two serious adverse effects, the study was stopped prematurely. In the subset of patients studied, NTG conferred no advantage over placebo in pain control (visual analogue scale at rest or during movement) and in satisfaction scores. CONCLUSIONS: The use of NTG patches conferred no advantage over the use of placebo in patients receiving patient-controlled morphine analgesia after total knee replacement. Two myocardial infarcts occurred in this group. Therefore, the safety of postoperative NTG patch use for pain control must be questioned. PMID:19532851

  14. Efficacy of rivastigmine tartrate, transdermal system, in Alzheimer's disease.

    PubMed

    Nieto, Rachel A; Deardorff, William James; Grossberg, George T

    2016-01-01

    As the most common major neurocognitive disorder, Alzheimer's disease (AD) will play an increasingly important role both socially and financially as the population ages. Approved treatments for AD are symptomatic in nature and show modest improvements in cognition and global functioning among patients with AD. This article focuses on the pharmacokinetics, pharmacodynamics, efficacy, and safety of the transdermal patch form of the cholinesterase inhibitor rivastigmine. The rivastigmine transdermal system is approved for the treatment of patients with mild, moderate, and severe AD. Three randomized trials have shown the rivastigmine patch to be efficacious and tolerable across all stages of AD. The rivastigmine patch offers several advantages over the capsule form, including decreased peak to trough plasma fluctuations, reduced rates of nausea and vomiting, better treatment adherence, higher probability of reaching the target dose, ease of administration, and greater satisfaction among caregivers. These factors may be especially important in patients with severe AD, in which patients are more vulnerable to adverse side effects from higher doses. While the patch is more expensive than generic therapies, patient populations that may benefit from the patch include those that are particularly sensitive to GI side effects, have chronic gastrointestinal problems, have difficulty swallowing medications, or have failed to respond with high doses of other generic options.

  15. Association of contact urticaria and allergic contact dermatitis to rubber.

    PubMed

    Fernadez, Ohalis Luanda; Canosa, Juliana Macedo; Lazzarini, Rosana; Duarte, Ida

    2009-01-01

    We present a case of a healthcare professional that developed type I and IV hypersensitivity reactions to rubber. During the clinical examination the patient showed eczematous dermatitis of the hands. The patch test was positive for thiuram group and an open test with a piece of glove was positive after 20 minutes of exposure. Allergen-specific IgE test (RAST) was relevant. Reactions to rubber allergens are frequent among healthcare professionals due to constant contact with this material.

  16. The Long-Term Safety of S-Flurbiprofen Plaster for Osteoarthritis Patients: An Open-Label, 52-Week Study.

    PubMed

    Yataba, Ikuko; Otsuka, Noboru; Matsushita, Isao; Matsumoto, Hideo; Hoshino, Yuichi

    2016-08-01

    The newly developed S-flurbiprofen plaster (SFPP) is a tape-type patch that shows innovative percutaneous absorption. This study was designed to evaluate the safety of a long-term 52-week SFPP application to osteoarthritis (OA) patients. This was a multi-center, open-label, uncontrolled prospective study that included 201 OA patients. SFPP at 40 mg/day was applied to the site of pain in 101 patients and at 80 mg/day (2 patches) in 100 patients at a total of 301 sites for 52 weeks. The affected sites assessed included the knee (192), lumbar spine (66), cervical spine (26), and others (17). Drug safety was evaluated by medical examination, laboratory tests, and examination of vital signs. Efficacy was evaluated by the patient's and clinician's global assessments and clinical symptoms. Most patients (80.1 %) completed the 52-week SFPP application. The majority of drug-related adverse events (AEs) included mild dermatitis at the application sites and occurred in 46.8 % of the sites. No photosensitive dermatitis was observed. Systemic AEs occurred in 9.0 % of the patients; a serious AE (gastric ulcer hemorrhage) occurred in one patient. No clinically significant changes in the laboratory tests and vital signs were observed. The efficacy evaluation showed an improvement from 2 weeks after the SFPP application, which continued during the 52 weeks' treatment. No apparent safety concerns were observed, even during the long-term SFPP application. Therefore, SFPP could be an additional pharmacotherapy in OA treatment.

  17. First epidemiological study of contact dermatitis in Spain - 1977. Spanish Contact Dermatitis Research Group.

    PubMed

    Camarasa, J M

    1979-01-01

    The present work is the first epidemiological study carried out by the Spanish Contact Dermatitis Research Group during 1977. During this year 2806 patients were studied with patch test among 30873 dermatological patients. The 60-62% of the totality had reactivity to one or more patches. Four major groups of allergens were able to consider, following the incidence in their power of sensitize. First group with strong incidence include: Nickel, Chromate, Cobalt, T.M.T.D.,P.P.D.A., Mercapto mix., and Wood tars. Second and third groups with medium incidence contain: Caines, Carbonates, Neomycin, Balsam of Peru, Mercury, Lanolin, Naphtyl mix., Formaldehyde, Benzalkonium chloride, P. P. D. A. mix, and Turpentine. Four group show very low incidence substances, as: Epoxi, Sulfonamides, Etilendiamine, Parabens, Chinoform, Colophony and Cinnamon oil. Few comments about age and occupations are included.

  18. Prevalence of fragrance contact allergy in the general population of five European countries: a cross-sectional study.

    PubMed

    Diepgen, T L; Ofenloch, R; Bruze, M; Cazzaniga, S; Coenraads, P J; Elsner, P; Goncalo, M; Svensson, Å; Naldi, L

    2015-12-01

    Contact allergy to fragrances is assessed mostly in clinical populations of patients. Studies in the general population are scarce and vary in their methodology across countries. To determine the prevalence of fragrance contact allergy in the European general population and to assess the clinical relevance of positive patch test reactions to different fragrances. In five European countries (Germany, Italy, the Netherlands, Portugal and Sweden) a random sample from the general population aged 18-74 years was drawn. In total, 12 377 subjects were interviewed in this cross-sectional study and a random sample (n = 3119) was patch tested using the TRUE Test and Finn Chamber techniques. Patch test procedures were harmonized by mandatory training before the study and monitoring during the study. The highest prevalence for contact allergy of 2·6% [95% confidence interval (CI) 2·1-3·2] was found for fragrance mix (FM) I in petrolatum, with a high content of atranol and chloratranol, followed by 1·9% (95% CI 1·5-2·4) for FM II in petrolatum. The conservatively estimated prevalence of fragrance contact allergy was 1·9% (95% CI 1·5-2·5). This is defined as the existence of a positive patch test to FM I or FM II; any of their individual materials; Myroxylon pereirae; sesquiterpene lactones or 3- and 4-hydroxyisohexyl 3-cyclohexene carboxaldehyde that show clinical relevance, defined conservatively as lifetime avoidance of scented products and an itchy skin rash lasting > 3 days in a lifetime. Using the reported lifetime prevalence of any contact dermatitis instead of the lifetime prevalence of any itchy skin rash, the prevalence is 0·8% (95% CI 0·5-1·2). The prevalence rates of contact allergy to fragrances in women are about twice those in men. This study helps to identify targets for prevention of fragrance allergy. © 2015 British Association of Dermatologists.

  19. Variation in aluminium patch test reactivity over time.

    PubMed

    Siemund, Ingrid; Mowitz, Martin; Zimerson, Erik; Bruze, Magnus; Hindsén, Monica

    2017-11-01

    Contact allergy to aluminium has been reported more frequently in recent years. It has been pointed out that positive patch test reactions to aluminium may not be reproducible on retesting. To investigate possible variations in patch test reactivity to aluminium over time. Twenty-one adults, who had previously reacted positively to aluminium, were patch tested with equimolar dilution series in pet. of aluminium chloride hexahydrate and aluminium lactate, four times over a period of 8 months. Thirty-six of 84 (43%) serial dilution tests with aluminium chloride hexahydrate and 49 of 84 (58%) serial dilution tests with aluminium lactate gave negative results. The range of reactivity varied between a negative reaction to aluminium chloride hexahydrate at 10% and/or to aluminium lactate at 12%, and a positive reaction to aluminium chloride hexahydrate at 0.1% and/or to aluminium lactate at 0.12%. The highest individual difference in test reactivity noticed was 320-fold when the two most divergent minimal eliciting concentrations were compared. The patch test reactivity to aluminium varies over time. Aluminium-allergic individuals may have false-negative reactions. Therefore, retesting with aluminium should be considered when there is a strong suspicion of aluminium contact allergy. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Eyelid Dermatitis: Contact Allergy to 3-(Dimethylamino)propylamine

    PubMed Central

    Knopp, Eleanor; Watsky, Kalman

    2014-01-01

    We present the case of a 42-year-old woman with intractable eyelid dermatitis. Patch testing revealed sensitization to 3-(dimethylamino)propylamine (DMAPA). DMAPA is an important etiology of allergic contact dermatitis of the eyelids and face but is easily missed even with expanded-series patch testing. We also review the most common causative allergens in eyelid dermatitis cited in the literature over the past decade. DMAPA is a reagent used in the formation of cocamidopropyl betaine (CAPB), a common additive to liquid soaps, shampoos, and other cleansing products because of its utility as a surfactant. Beginning in the 1980s, reports of allergy to CAPB surfaced in the literature. Ultimately, a majority of patch testing studies have shown that clinical allergy to CAPB-containing products actually reflects allergy to contaminant DMAPA in most cases. Amidoamine, another intermediate in the formation of CAPB, may also be implicated through a proposed mechanism of conversion to DMAPA in the skin. When patch-testing for eyelid and facial dermatitis, it is crucial to test with DMAPA directly, not just with CAPB; unlike commercial-grade CAPB, the CAPB in patch test kits is ultrapure and does not contain contaminant DMAPA. PMID:19134437

  1. Modified automatic R-peak detection algorithm for patients with epilepsy using a portable electrocardiogram recorder.

    PubMed

    Jeppesen, J; Beniczky, S; Fuglsang Frederiksen, A; Sidenius, P; Johansen, P

    2017-07-01

    Earlier studies have shown that short term heart rate variability (HRV) analysis of ECG seems promising for detection of epileptic seizures. A precise and accurate automatic R-peak detection algorithm is a necessity in a real-time, continuous measurement of HRV, in a portable ECG device. We used the portable CE marked ePatch® heart monitor to record the ECG of 14 patients, who were enrolled in the videoEEG long term monitoring unit for clinical workup of epilepsy. Recordings of the first 7 patients were used as training set of data for the R-peak detection algorithm and the recordings of the last 7 patients (467.6 recording hours) were used to test the performance of the algorithm. We aimed to modify an existing QRS-detection algorithm to a more precise R-peak detection algorithm to avoid the possible jitter Qand S-peaks can create in the tachogram, which causes error in short-term HRVanalysis. The proposed R-peak detection algorithm showed a high sensitivity (Se = 99.979%) and positive predictive value (P+ = 99.976%), which was comparable with a previously published QRS-detection algorithm for the ePatch® ECG device, when testing the same dataset. The novel R-peak detection algorithm designed to avoid jitter has very high sensitivity and specificity and thus is a suitable tool for a robust, fast, real-time HRV-analysis in patients with epilepsy, creating the possibility for real-time seizure detection for these patients.

  2. Clinical and immunological characteristics of a pediatric population with food protein-induced enterocolitis syndrome (FPIES) to fish.

    PubMed

    González-Delgado, Purificación; Caparrós, Esther; Moreno, M Victoria; Clemente, Fernando; Flores, Emilio; Velásquez, Laura; Rubio, Gonzalo; Fernández, Javier

    2016-05-01

    Food protein-induced enterocolitis (FPIES) is an uncommon, non-IgE-mediated food allergy that usually debuts in infancy with profuse vomiting, lethargy, and pallor 2-4 h following ingestion of the offending food. Its immune mechanism is not known. We aimed to describe the clinical features and outcome of children with fish-FPIES as well as to investigate on cellular immune response implicated. Prospective and follow-up clinical study of children with FPIES by fish over a period between 2004 and 2013 was conducted. Measurement in vitro of both cytokine production in peripheral blood mononuclear cells (PBMCs) and expression of HLA-DR in monocyte-derived dendritic cells stimulated with fish extracts. Sixteen children (seven male and nine female) were included, with a mean age of onset at 10 months. Diagnosis was established after a median of 4 reactions. Twelve patients were treated in emergency room, and two were admitted in intensive care. Patch tests were positive in six patients. Skin prick tests (SPTs) and specific IgE to all fish tested were negative. Only three children reached tolerance at a mean age of 4.5 years. Eight children avoided fish because of positive oral food challenge (OFC) after 6 years of age. Other patients have not been challenged because of parent refusal to OFC or a recent diagnosis. TNF-α was increased in patients, and a significant elevation of the HLA-DR marker was also observed in these patients vs. control donors. FPIES caused by fish in many cases presents with severe clinical manifestations. Patch test has poor diagnostic value, and OFC is the gold standard to test tolerance. The cytokine TNF-α may be implicated in the clinical symptoms. Higher expression of HLA-DR in dendritic cells has also been detected in our patients. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Tolerability, usability and acceptability of dissolving microneedle patch administration in human subjects

    PubMed Central

    Arya, Jaya; Henry, Sebastien; Kalluri, Haripriya; McAllister, Devin V.; Pewin, Winston P.; Prausnitz, Mark R.

    2017-01-01

    To support translation of microneedle patches from pre-clinical development into clinical trials, this study examined the effect of microneedle patch application on local skin reactions, reliability of use and acceptability to patients. Placebo patches containing dissolving microneedles were administered to fifteen human participants. Microneedle patches were well tolerated in the skin with no pain or swelling and only mild erythema localized to the site of patch administration that resolved fully within seven days. Microneedle patches could be administered by hand without the need of an applicator and delivery efficiencies were similar for investigator-administration and self-administration. Microneedle patch administration was not considered painful and the large majority of subjects were somewhat or fully confident that they self-administered patches correctly. Microneedle patches were overwhelmingly preferred over conventional needle and syringe injection. Altogether, these results demonstrate that dissolving microneedle patches were well tolerated, easily usable and strongly accepted by human subjects, which will facilitate further clinical translation of this technology. PMID:28285193

  4. Portable Holographic Interferometry Testing System: Application to crack patching quality control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heslehurst, R.B.; Baird, J.P.; Williamson, H.M.

    Over recent years the repair of metallic structures has been improved through the use of patches fabricated from composite materials and adhesively bonded to the damaged area. This technology is termed crack patching, and has been successfully and extensively used by the RAAF and the USAF. However, application of the technology to civilian registered aircraft has had limited success due to the apparent lack of suitable quality assurance testing methods and the airworthiness regulators concern overpatch adhesion integrity. Holographic interferometry has previously shown the advantages of detecting out-of-plane deformations of the order of the wavelength of light (1{mu}). Evidence willmore » be presented that holography is able to detect changes in load path due to debonds and weakened adhesion in an adhesively bonded patch. A Portable Holographic Interferometry Testing System (PHITS) which overcomes the vibration isolation problem associated with conventional holography techniques has been developed. The application of PHITS to crack patching technology now provides a suitable method to verify the integrity of bonded patches in-situ.« less

  5. Preliminary Experience with Transdermal Oxybutynin Patches for Hyperhidrosis.

    PubMed

    Bergón-Sendín, M; Pulido-Pérez, A; Sáez-Martín, L C; Suárez-Fernández, R

    2016-12-01

    Hyperhidrosis is very common and has a considerable impact on patients' quality of life. While oral oxybutynin is associated with good response rates, adverse effects are common and frequently cause patients to stop treatment. Following the recent launch of oxybutynin in a transdermal patch formulation in Spain, we undertook a preliminary study to assess treatment response and adverse effects in patients with hyperhidrosis. This prospective study of 25 patients treated twice weekly with transdermal oxybutynin patches over 10 weeks assessed treatment response on 2 subjective scales: the Hyperhidrosis Disease Severity Scale (HDSS) and a visual analog scale (VAS) for sweating. Sixty percent of patients showed an improvement in HDSS scores. VAS scores improved in all cases, and 68% of patients achieved a reduction of 3 points or more. Just 2 patients (8%) experienced treatment-related adverse effects (irritant dermatitis at the patch application site in both cases). Although our results are based on a small sample, they suggest that transdermal oxybutynin could be a useful option for the treatment of hyperhidrosis and that it has an excellent safety and tolerability profile. Copyright © 2016 AEDV. Publicado por Elsevier España, S.L.U. All rights reserved.

  6. [Efficacy of Topical Agents for Symptomatic Treatment of Rotigotine Patch-Induced Skin Disorders].

    PubMed

    Yasutaka, Yuki; Fujioka, Shinsuke; Shibaguchi, Hirotomo; Kiyomi, Fumiaki; Hara, Koyomi; Ogata, Kentaro; Tsuboi, Yoshio; Kamimura, Hidetoshi

    2017-09-01

    Since the effect of a percutaneous absorption-type dopamine agonist (DA) preparation, rotigotine patch, stably persists by once-a-day application, this dosage form is appropriate for Parkinson's disease patients showing levodopa induced wearing off phenomenon. On the other hand, skin disorders, mainly application site reaction, are characteristic problems associated with use of the patch. In this study, to clarify the influence of a topical agent used to prevent or treat rotigotine patch-induced skin disorder on continuation of the patch application, patients who started rotigotine patch application at our hospital were retrospectively surveyed. The one-year continuation rate of rotigotine patch application was 37.3% (53 of 142 cases). It was insufficient to prevent skin disorders, only by the pre-treatment of a moisturizing agent alone. Regarding the effective rate of topical agents used to treat skin disorders, that of very strong-class steroids was 89.5%, being significantly higher than those of weak steroids, moisturizing agents, and antihistamines. It was suggested that for countermeasures against rotigotine patch-induced skin disorders, treatment with very strong-class steroids for external use early after development of skin disorders is more effective than preventive treatment with topical agents regardless of the type. (Received March 30, 2017; Accepted May 16, 2017; Published September 1, 2017).

  7. Methylphenidate Transdermal System: A Multisite, Open-Label Study of Dermal Reactions in Pediatric Patients Diagnosed With ADHD

    PubMed Central

    Squires, Liza; Li, Yunfeng; Civil, Richard; Paller, Amy S.

    2010-01-01

    Objective: To characterize dermal reactions and examine methylphenidate (MPH) sensitization in subjects receiving methylphenidate transdermal system (MTS). Method: This multicenter, open-label, dose-optimization study utilized MTS doses of 10, 15, 20, and 30 mg in children aged 6 to 12 years, inclusive (N = 305), with a DSM-IV-TR primary diagnosis of attention-deficit/hyperactivity disorder. The study was conducted between January 8, 2007, and August 23, 2007. Subjects wore MTS on their hips for 9 hours per day, alternating sides daily for a total of 7 weeks. Assessments included the Experience of Discomfort scale, Transdermal System Adherence scale, and Dermal Response Scale (DRS; 0 = no irritation, 7 = strong reaction). On-study reevaluations were conducted to characterize DRS scores ≥ 4. Epicutaneous allergy patch testing was conducted for DRS scores ≥ 6, persistent DRS scores ≥ 4, DRS score increase following an assessment of ≥ 4, or DRS scores of 4 or 5 following elective discontinuation. Results: Approximately half of subjects experienced definite erythema at the patch site that generally dissipated within 24 hours. Four subjects experienced a DRS score of 4 (1%): erythema in 1 subject resolved on study treatment, 2 cases resolved poststudy and subjects tolerated oral MPH, and 1 subject discontinued treatment. The latter subject was referred for patch testing and was diagnosed with allergic contact sensitization to MPH. Conclusions: Few severe dermal effects were seen with MTS treatment. Dermal reactions were characterized as contact dermatitis and dissipated rapidly. On patch testing, 1 subject (0.3%) manifested sensitization to MPH. Trial Registration: clinicaltrials.gov Identifier: NCT00434213 PMID:21494336

  8. Comparison of transdermal diclofenac patch with oral diclofenac as an analgesic modality following multiple premolar extractions in orthodontic patients: A cross over efficacy trial

    PubMed Central

    Bhaskar, Hemant; Kapoor, Pranav; Ragini

    2010-01-01

    Aims: This study was performed to compare the degree of post operative analgesia, patient compliance, and frequency of adverse events with the use of oral diclofenac tablets and transdermal diclofenac patch following multiple premolar extractions in patients undergoing orthodontic treatment. Materials and Methods: Twenty young pre-orthodontic patients requiring bilateral maxillary and mandibular first premolar extractions were selected for the study. The right maxillary and mandibular first premolars were extracted first and 50 mg oral diclofenac sodium tablets were prescribed to be taken thrice a day for three days. In the next appointment, the contralateral first premolars were extracted and a 100 mg transdermal diclofenac patch was applied once a day for three days. Pain relief and pain intensity with both the diclofenac formulations was recorded for each of the three postoperative days using 5-point Verbal Pain Intensity and Pain Relief Score Charts. Results and Conclusions: Statistical analyses revealed that there was a gradual increase in pain relief scores and a gradual decrease in pain intensity scores with the use of oral diclofenac tablets as well as with the transdermal patch. However, subjects reported that they were more comfortable using the transdermal patch particularly due to the once-a-day application and lesser frequency of systemic adverse effects. Results of this study indicate that the transdermal diclofenac patch provides as potent analgesia as the oral diclofenac tablets with the added advantage of better patient compliance and may be used for routine post extraction analgesia. PMID:22114407

  9. Nicotine patches improve mood and response speed in a lexical decision task.

    PubMed

    Gentry, M V; Hammersley, J J; Hale, C R; Nuwer, P K; Meliska, C J

    2000-01-01

    The effects of smoking a cigarette or wearing a transdermal nicotine patch on mood and lexical decision-making were tested in eight smokers. Each participant was tested after 4 hours of smoking abstinence, under 4 conditions: placebo (very low nicotine) cigarette, nicotine cigarette, placebo patch, and nicotine patch. Relative to placebo, wearing the nicotine patch reduced Profile of Mood States (POMS) Total Mood Disturbance and Fatigue/Inertia scores, while increasing the speed of some types of lexical decisions. Smoking a nicotine cigarette did not affect reaction times, but unexpectedly decreased the accuracy of Word/ Nonword lexical decisions. Thus, transdermal nicotine may improve mood and facilitate longterm memory search and/or attentional processes in nicotine-deprived smokers.

  10. Stiffness and strength of fiber reinforced polymer composite bridge deck systems

    NASA Astrophysics Data System (ADS)

    Zhou, Aixi

    This research investigates two principal characteristics that are of primary importance in Fiber Reinforced Polymer (FRP) bridge deck applications: STIFFNESS and STRENGTH. The research was undertaken by investigating the stiffness and strength characteristics of the multi-cellular FRP bridge deck systems consisting of pultruded FRP shapes. A systematic analysis procedure was developed for the stiffness analysis of multi-cellular FRP deck systems. This procedure uses the Method of Elastic Equivalence to model the cellular deck as an equivalent orthotropic plate. The procedure provides a practical method to predict the equivalent orthotropic plate properties of cellular FRP decks. Analytical solutions for the bending analysis of single span decks were developed using classical laminated plate theory. The analysis procedures can be extended to analyze continuous FRP decks. It can also be further developed using higher order plate theories. Several failure modes of the cellular FRP deck systems were recorded and analyzed through laboratory and field tests and Finite Element Analysis (FEA). Two schemes of loading patches were used in the laboratory test: a steel patch made according to the ASSHTO's bridge testing specifications; and a tire patch made from a real truck tire reinforced with silicon rubber. The tire patch was specially designed to simulate service loading conditions by modifying real contact loading from a tire. Our research shows that the effects of the stiffness and contact conditions of loading patches are significant in the stiffness and strength testing of FRP decks. Due to the localization of load, a simulated tire patch yields larger deflection than the steel patch under the same loading level. The tire patch produces significantly different failure compared to the steel patch: a local bending mode with less damage for the tire patch; and a local punching-shear mode for the steel patch. A deck failure function method is proposed for predicting the failure of FRP decks. Using developed laminated composite theories and FEA techniques, a strength analysis procedure containing ply-level information was proposed and detailed for FRP deck systems. The behavior of the deck's unsupported (free) edges was also investigated using ply-level FEA.

  11. Concomitant abdominoplasty and umbilical hernia repair using the Ventralex hernia patch.

    PubMed

    Neinstein, Ryan M; Matarasso, Alan; Abramson, David L

    2015-04-01

    Patients requesting abdominoplasty often have concomitant umbilical hernias and may request simultaneous treatment. The vascularity of the umbilicus is potentially at risk during these combined procedures. In this study, the authors present a technique for treating umbilical hernias at the time of abdominoplasty surgery using the Ventralex hernia patch. A total of 11 female patients with a mean age of 39.4 years (range, 28 to 51 years) undergoing abdominoplasty with umbilical hernia repair with the Ventralex patch were included. The mean body mass index was 27.6 kg/m (range, 20 to 34 kg/m). No vascular compromise of the umbilicus was seen. The hernia repair did not alter the abdominoplasty results. One patient had transient umbilical swelling postoperatively that resolved within 6 months postoperatively. The authors present a series of umbilical hernia repairs in abdominoplasty patients using a minimal access incision by means of the rectus fascia and the Ventralex patch that is fast and reliable and preserves the blood supply to the umbilicus.

  12. Pilot study of contact sensitization to rubber allergens and bisphenol A amongst dental students.

    PubMed

    Lyapina, Maya Grigorievna; Krasteva, Assya; Dencheva, Maria; Tzekova, Mariana; Nikolov, Georgy; Yaneva-Deliverska, Mariela; Kisselova-Yaneva, Angelina

    2017-05-08

    The aim of this study has been to evaluate the rate of contact sensitization to some rubber allergens and to bisphenol A (BPA) amongst students of dental medicine and dental patients. A total of 50 participants were included in the study: 40 students of dental medicine exposed to the studied rubber allergens and BPA-based dental materials during the course of their education; 10 dental patients without occupational exposure to the latter substances served as a control group. All of them were patch-tested with the studied rubber allergens and bisphenol A. Highest was the sensitizing action of carba mix, followed by benzoyl peroxide and mercapto mix. The sensitization rate for carba mix was significantly higher for dental students as well as for the whole studied population, if compared to the one for thiuram mix (Chi2 = 12.9, p < 0.001; Chi2 = 13.9, p < 0.001), bisphenol A (Chi2 = 8.9, p < 0.001; Chi2 = 11.9, p < 0.001), toluenesulfonamide formaldehyde resin (Chi2 = 10.7, p < 0.001; Chi2 = 13.9, p < 0.001) and benzoyl peroxide (Chi2 = 4.7, p = 0.03; Chi2 = 5.8, p = 0.016), and for dental patients, if compared to the one for mercapto mix (Chi2 = 7.07, p = 0.008). Concomitant positive skin patch-test reactions to carba mix and to benzoyl peroxide, and to all the studied allergens were established. Carba mix could be outlined as a sensitizer of paramount importance for dental students as well as for dental patients. Benzoyl peroxide was the second ranked sensitizer for dental students. Positive skin patch-test reactions to bisphenol A and toluenesulfonamide formaldehyde resin were established only among the group of dental students. Int J Occup Med Environ Health 2017;30(3):397-405. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  13. Flu Vaccine Skin Patch Tested

    MedlinePlus

    ... Subscribe September 2017 Print this issue Health Capsule Flu Vaccine Skin Patch Tested En español Send us ... Each year, millions of people nationwide catch the flu. The best way to protect yourself is to ...

  14. Can exposure limitations for well-known contact allergens be simplified? An analysis of dose-response patch test data.

    PubMed

    Fischer, Louise Arup; Menné, Torkil; Voelund, Aage; Johansen, Jeanne Duus

    2011-06-01

    Allergic contact dermatitis is triggered by chemicals in the environment. Primary prevention is aimed at minimizing the risk of induction, whereas secondary and tertiary prevention are aimed at reducing elicitation. To identify the elicitation doses that will elicit an allergic reaction in 10% of allergic individuals under patch test conditions (ED(10) patch test) for different allergens, and to compare the results with those for different allergens and with animal data indicating sensitizing potency from the literature. The literature was searched for patch test elicitation studies that fulfilled six selected criteria. The elicitation doses were calculated, and fitted dose-response curves were drawn. Sixteen studies with eight different allergens-methylchloroisothiazolinone/ methylisothiazolinone, formaldehyde, nickel, cobalt, chromium, isoeugenol, hydroxyiso hexyl 3-cyclohexene carboxaldehyde, and methyldibromo glutaronitrile-were selected. The median ED(10) value was 0.835 µg/cm(2). The ED(10) patch test values were all within a factor of 7 from the lowest to the highest value, leaving out three outliers. No obvious patterns between the sensitization and elicitation doses for the allergens were found. We found a rather small variation in the ED(10) patch test between the allergens, and no clear relationship between induction potency and elicitation threshold of a range of allergens. This knowledge may stimulate thoughts on introducing a generic approach for limitations in exposure to well-known allergens. © 2011 John Wiley & Sons A/S.

  15. Occupational contact dermatitis due to essential oils.

    PubMed

    Trattner, Akiva; David, Michael; Lazarov, Aneta

    2008-05-01

    Allergic contact dermatitis induced by the occupational use of products containing essential oils has not been studied comprehensively. The aim of the present report was to describe the characteristics, diagnosis, and outcome of 5 patients with occupational contact dermatitis because of essential oils attending our outpatient dermatology clinics over a 2-year period. These patients are added to the 11 cases reported thus far in the literature. The research shows that for proper diagnosis, patch tests with the standard series and the fragrance series should be performed, in addition to tests with the specific oils to which the patients were exposed. Patients should be instructed to avoid the allergens identified. Sensitization to essential oils has important implications for the occupational future of affected individuals.

  16. (Meth)Acrylate Occupational Contact Dermatitis in Nail Salon Workers: A Case Series.

    PubMed

    DeKoven, Samuel; DeKoven, Joel; Holness, D Linn

    Recently, many cases of acrylate-associated allergic contact dermatitis have appeared among nail salon workers. Common acrylate-containing products in nail salons include traditional nail polish, ultraviolet-cured shellac nail polish, ultraviolet-cured gel nails, and press-on acrylic nails. Nail salon technicians seen in the occupational medicine clinic in 2015 and 2016 were identified, and their patch test results and clinical features were summarized. Patch testing was done with the Chemotechnique (Meth)Acrylate nail series, and either the North American Standard series or the North American Contact Dermatitis Group screening series. Six patients were identified, all women, ages 38 to 58. Common presentations included erythematous dermatitis of the dorsa of the hands, palms, and forearms and fissures on the fingertips. Less common sites of eruptions included the periorbital region, cheeks, posterior ears, neck, sacral area, lateral thighs, and dorsa of the feet. All patients reacted to hydroxyethyl methacrylate, and 5 patients reacted to ethyl acrylate. Each patient also reacted to (meth)acrylates that are not found on either standard series, including ethyleneglycol dimethacrylate, 2-hydroxypropyl methacrylate, and 2-hydroxyethyl acrylate. The authors report 6 cases of allergic contact dermatitis to acrylates in nail technicians seen over the past year, representing a new trend in their clinic. These cases are reflective of a growing trend of nail technicians with allergic contact dermatitis associated with occupational (meth)acrylate exposure. Efforts to improve prevention are needed.

  17. Contact allergy to epoxy (meth)acrylates.

    PubMed

    Aalto-Korte, Kristiina; Jungewelter, Soile; Henriks-Eckerman, Maj-Len; Kuuliala, Outi; Jolanki, Riitta

    2009-07-01

    Contact allergy to epoxy (meth)acrylates, 2,2-bis[4-(2-hydroxy-3-methacryloxypropoxy) phenyl]propane (bis-GMA), 2,2-bis[4-(2-hydroxy-3-acryloxypropoxy)phenyl]-propane (bis-GA), 2,2-bis[4-(methacryl-oxyethoxy)phenyl] propane (bis-EMA), 2,2-bis[4-(methacryloxy)phenyl]-propane (bis-MA), and glycidyl methacrylate (GMA) is often manifested together with contact allergy to diglycidyl ether of bisphenol A (DGEBA) epoxy resin. To analyse patterns of concomitant allergic reactions to the five epoxy (meth)acrylates in relation to exposure. We reviewed the 1994-2008 patch test files at the Finnish Institute of Occupational Health (FIOH) for reactions to the five epoxy (meth)acrylates, and examined the patients' medical records for exposure. Twenty-four patients had an allergic reaction to at least one of the studied epoxy (meth)acrylates, but specific exposure was found only in five patients: two bis-GMA allergies from dental products, two bis-GA allergies from UV-curable printing inks, and one bis-GA allergy from an anaerobic glue. Only 25% of the patients were negative to DGEBA epoxy resin. The great majority of allergic patch test reactions to bis-GMA, bis-GA, GMA and bis-EMA were not associated with specific exposure, and cross-allergy to DGEBA epoxy resin remained a probable explanation. However, independent reactions to bis-GA indicated specific exposure. Anaerobic sealants may induce sensitization not only to aliphatic (meth)acrylates but also to aromatic bis-GA.

  18. The effectiveness of an adhesively bonded composite patch repair as applied to a transport aircraft lower wing skin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ruschau, J.J.; Coate, J.E.

    1996-12-31

    Specimens were machined from lower wing skin extrusions of a transport aircraft, precracked under fatigue loading, repaired with a boron/epoxy patch, and subsequently fatigue tested under simulated flight loading conditions to evaluate the effectiveness of an adhesively bonded repair patch. Testing was performed at RT and -54{degrees}C for two configurations: one with the crack running up the integral stiffener (riser), the other running down the riser towards the outer skin surface. Cracks were initiated from a single 6.35 mm diameter hole located in the riser portion of the 7075-T6 wing skin material. Ultrasonic inspections were performed during fatigue loading tomore » determine crack growth and damage underneath the patch. Limited results show the adhesively bonded patch was successful in stopping or greatly reducing any further crack growth. Under laboratory air conditions, no crack growth occurred following 30,000 equivalent flight hours, double the expected life of the patched structure. Similarly at -54{degrees}C, no crack growth was observed for a patched crack growing up the riser following 15,000 EFH. For the case of a crack growing down the riser at the lower test temperature, some crack growth was measured, though at a greatly reduced rate.« less

  19. Transdermal rivastigmine: management of cutaneous adverse events and review of the literature.

    PubMed

    Greenspoon, Jill; Herrmann, Nathan; Adam, David N

    2011-07-01

    Alzheimer's disease is a chronic neurodegenerative disorder resulting in part from the degeneration of cholinergic neurons in the brain. Rivastigmine, a cholinesterase inhibitor, is commonly used as a treatment for dementia due to its ability to moderate cholinergic neurotransmission; however, treatment with oral rivastigmine can lead to gastrointestinal adverse effects such as nausea and vomiting. Transdermal administration of rivastigmine can minimize these adverse effects by providing continuous delivery of the medication, while maintaining the effectiveness of the oral treatment. While the transdermal form of rivastigmine has been found to have fewer systemic adverse effects compared with the oral form, cutaneous reactions, such as contact dermatitis, can lead to discontinuation of the drug in its transdermal form. Lack of patient compliance with regard to applying the patch to the designated site, applying the patch for the correct length of time or rotating patch application sites increases the risk of cutaneous adverse reactions. This article outlines the diagnosis and management of irritant contact dermatitis and allergic contact dermatitis secondary to transdermal rivastigmine. The large majority of reactions to transdermal patches are of an irritant type, which can be diagnosed clinically by the presence of a pruritic, erythematous, eczematous plaque strictly confined to the borders of the patch. In contrast, an allergic reaction can be differentiated by the presence of vesicles and/or oedema, erythema beyond the boundaries of the transdermal patch and lack of improvement of the lesion 48 hours after removal of the offending treatment. By encouraging the patient to follow a regular rotation schedule for the patch, and using lipid-based emollients for irritant dermatitis and pre- and post-treatment topical corticosteroids for allergic dermatitis, cutaneous reactions can often be alleviated and patients can continue with their medication regimen. Other simple changes to a patient's treatment routine, including minimizing the use of harsh soaps, avoiding recently shaven or damaged areas of skin and carefully removing the patch after use, can help to further decrease the risk of dermatitis development.

  20. Mild balanoposthitis.

    PubMed Central

    Fornasa, C V; Calabrŏ, A; Miglietta, A; Tarantello, M; Biasinutto, C; Peserico, A

    1994-01-01

    AIM--To identify and study cases of mild balanoposthitis (MBP) with penile pathology among patients observed at a dermatology clinic over an 18-month period. MATERIALS--The study included 321 patients with penile pathology. The term MBP was used to describe balanoposthitis of a localised, inflammatory nature with few, non-specific symptoms and a tendency to become chronic or recur. Two hundred and seventy had diseases clearly identifiable by clinical examination or laboratory tests; 51 cases were diagnosed as MBP and these patients had blood tests (to evaluate immune status) and microbiological examination; when these proved negative, a series of patch tests was also used. RESULTS--Of the 51 patients diagnosed as having MBP, the cause was ascertained in 34 cases (infection, mechanical trauma, contact irritation, contact allergy, etc.), whereas no specific aetiological factor was detected to explain the symptoms in the remaining 17 cases. PMID:8001949

  1. Bilateral patching in retinal detachment: fluid mechanics and retinal "settling".

    PubMed

    Foster, William J

    2011-07-20

    When a patient suffers a retinal detachment and surgery is delayed, it is known clinically that bilaterally patching the patient may allow the retina to partially reattach or "settle." Although this procedure has been performed since the 1860s, there is still debate as to how such a maneuver facilitates the reattachment of the retina. Finite element calculations using commercially available analysis software are used to elucidate the influence of reduction in eye movement caused by bilateral patching on the flow of subretinal fluid in a physical model of retinal detachment. It was found that by coupling fluid mechanics with structural mechanics, a physically consistent explanation of increased retinal detachment with eye movements can be found in the case of traction on the retinal hole. Large eye movements increase vitreous traction and detachment forces on the edge of the retinal hole, creating a subretinal vacuum and facilitating increased subretinal fluid. Alternative models, in which intraocular fluid flow is redirected into the subretinal space, are not consistent with these simulations. The results of these simulations explain the physical principles behind bilateral patching and provide insight that can be used clinically. In particular, as is known clinically, bilateral patching may facilitate a decrease in the height of a retinal detachment. The results described here provide a description of a physical mechanism underlying this technique. The findings of this study may aid in deciding whether to bilaterally patch patients and in counseling patients on pre- and postoperative care.

  2. Transdermal Patches for the Treatment of Neurologic Conditions in Elderly Patients: A Review

    PubMed Central

    Somogyi, Monique

    2011-01-01

    Objective: The mode of drug delivery can be an important consideration in optimizing drug therapy, as it can affect treatment compliance and outcomes. It is particularly important to develop optimal drug formulations for chronic diseases or conditions in the elderly for which treatment compliance is known to be low. In this review, the features and benefits of transdermal formulations for treating neurologic conditions in elderly patients are described. Data Sources: English-language articles were identified by searching MEDLINE in November 2010 (there were no search parameters on date of publication) using the search terms transdermal patch, transdermal system, neurology, rivastigmine, rotigotine, selegiline, lidocaine, capsaicin, compliance, and neuropathic pain. Data Selection: Articles describing the development, use, efficacy, and safety of licensed transdermal patch treatments for neurologic conditions that affect the elderly were included. Data Extraction: The features of transdermal systems and comparisons between transdermal and oral formulations for the treatment of specific neurologic conditions in elderly patients were reviewed. Data Synthesis: There are 5 transdermal patch systems currently available for neurologic conditions in adults: rivastigmine, rotigotine, selegiline, lidocaine, and capsaicin. These are all modern formulations in matrix patches, developed to provide appropriate drug dosage in an acceptable and well-tolerated form. Conclusions: Transdermal patches can offer benefits to patients over oral formulations in terms of ease of use, simple treatment regimens, avoidance of the first-pass effect, and avoidance of high maximum plasma concentrations with rapid changes in drug levels, without the invasive procedures associated with intravenous treatment. PMID:22454804

  3. Outcomes of 3 hours part-time occlusion treatment combined with near activities among children with unilateral amblyopia.

    PubMed

    Alotaibi, Abdullah G; Fawazi, Samah M; Alenazy, Badriah R; Abu-Amero, Khaled K

    2012-04-01

    To evaluate the outcome of part-time occlusion therapy with or without near activities in monocular amblyopic patients. One hundred and thirty patients who prescribed daily occlusion therapy (part-time occlusion) were followed-up for a 12-week period. The study was carried out in the Pediatric Ophthalmology and Orthoptics Clinics of King Abdul-Aziz University Hospital, Riyadh, Saudi Arabia for the period from January to November 2010. Sixty-five patients were recommended to undertake the 3 hours of near visual activities (such as reading a book during patching) while the other 65 patients were not advised to do any near activity. Main outcome measures were best corrected visual acuity (VA) for both groups and line improvement. The total line of VA improved from baseline by an average of 6.7+/-2.37 line log MAR (logarithm of the minimum angle of resolution) units in the group of patching with near activities and by an average of 5.3+/- 2.04 line log MAR units in the group of patching without near activities. All type of amblyopia (strabismic, anisometropic, and mixed types of amblyopia) improved significantly after patching with near activities. Both moderate and severe amblyopia improved significantly in the group of near activities compared with the group without near activities. Performing near activities while patching in the treatment of anisometropic, stabismic, or combined amblyopia improves the VA outcome more than patching alone.

  4. Occupational protein contact dermatitis in food handlers.

    PubMed

    Hjorth, N; Roed-Petersen, J

    1976-02-01

    The preparation of food in restaurant kitchens carries a high risk of occupational dermatoses. Analysis of 33 cases revealed four different etiological types. Simple irritant dermatitis was rare (2 cases), plain contact dermatitis was more common (6 cases). Fifteen patients had relevant patch tests and scratch tests; ten had positive scratch tests only to explain the cause of their dermatitis. The last type was termed protein contact dermatitis. The major type IV allergens incriminated were metals, onion and garlic. The major proteinaceous allergens indicated by history and test results were fish and shell-fish. Open patch tests with the incriminated foods may cause erythema or oedema on normal skin after 20 minutes. Previously eczematous, now normal looking, skin often responds with a crop of dyshidrotic vesicles preceded by erythema and itching 30 minutes after the application of an open test. Examination for specific IgE is not always positive in such cases. Inhalant allergy was rare. The results indicate that food handlers are sensitized by the protein they touch, and then react to later contact with the proteins. Protein contact dermatitis is similarly common among veterinary surgeons, while the importance in other occupational groups remains to be studied.

  5. Evidence that two alkyl ester quaternary ammonium compounds lack substantial human skin-sensitizing potential.

    PubMed

    Jowsey, Ian R; Kligman, Albert M; White, Ian R; Goossens, An; Basketter, David A

    2007-03-01

    Alkyl ester quaternary ammonium compounds (ester quats) are used extensively in fabric rinse conditioners. It is important to document in the literature the outcome of historical studies that were performed to assess the risk of adverse skin effects associated with their use. (1) To document the outcomes of historical studies performed to evaluate the skin sensitizing potential of two ester quats (the di-[hardened tallow fatty acid] ester of 2,3-dihydroxypropyl-trimethyl ammonium chloride [HEQ] and the dialkyl ester of triethanol ammonium methyl sulfate [TEA-Quat]) and (2) to demonstrate that these ester quats lack marked skin-sensitizing potential in humans, such that they do not present a risk of contact allergy for consumers who use fabric rinse conditioners. Each material was assessed in the human maximization test in a panel of 25 volunteers. Diagnostic patch testing was also performed with each material in a population of 239 patients undergoing routine patch testing for suspected allergic contact dermatitis. These data are also considered in the context of an exposure-based quantitative risk assessment. Neither HEQ nor TEA-Quat was found to cause skin sensitization under the conditions of the human maximization test. No evidence of contact allergy to the materials was found among the relatively small population assessed by diagnostic patch testing. This study provides evidence that HEQ and TEA-Quat lack substantial skin-sensitizing potential in humans. Taken together with similar data for other ester quats, it suggests that compounds in this class are unlikely to be significant human contact allergens.

  6. Polyamine sensitization in offshore workers handling drilling muds.

    PubMed

    Ormerod, A D; Wakeel, R A; Mann, T A; Main, R A; Aldridge, R D

    1989-11-01

    Oil-based mud, a complex mixture containing amines in emulsifiers, is used in offshore drilling operations. It is a skin irritant that occasionally gives rise to allergic contact sensitivity. In patch testing patients with allergy to drilling mud, we have identified polyamine (diethylenetriamine and triethylenetetramine) sensitivity in 5 patients. All 5 patients were also allergic to emulsifiers. These emulsifiers are cross-linked fatty acid amido-amines, in which unreacted amine groups are thought to cross-sensitize with these constituent polyamines. Cross-reactivity between ethylenediamine, diethylenetetramine and triethylenetetramine was found in 9 subjects.

  7. Comparison between over-glasses patching and adhesive patching for children with moderate amblyopia: a prospective randomized clinical trial.

    PubMed

    Kim, Su Jin; Jeon, Hyeshin; Jung, Jae Ho; Lee, Kwang Min; Choi, Hee Young

    2018-02-01

    To investigate efficacy of over-glasses patching treatment for amblyopic children using visual function improvement and Amblyopia Treatment Index (ATI) changes. In a randomized multi-center controlled clinical trial, 107 children aged 3-7 years with moderate amblyopia (visual acuity in the range of 20/40 to 20/100) were included to receive treatment with either an adhesive skin patch or a fabric over-glasses patch. The patients were prescribed 2 h of patching per day for the sound eye. Best-corrected visual acuity (BCVA) was investigated and ATI questionnaires were collected from parents at 5 weeks and 17 weeks after the initiation of treatment. ATI identifies barriers and problems associated with amblyopia treatment. We compared the changes of visual acuity of amblyopic eyes and ATI scores in two groups. At 17 weeks, the mean visual acuity of the amblyopic eye using Snellen chart improved 3.2 lines in the adhesive patching group and 2.7 lines for an over-glasses patching method that fit over eyeglasses (p = 0.345). A similar proportion of subjects in each group had improvement of ≥ 2 lines (adhesive patching group 67% vs over-glasses patching group 67%, p = 0.372). There was also no difference in treatment burden in each group as measured with the Amblyopia Treatment Index. The only item to demonstrate a significant difference between groups was that related to "Treatment makes the eye or eyelids red" (mean 4.0 ± 1.1 vs 3.0 ± 1.0 at 17 weeks, p = 0.001, for adhesive vs over-glasses patch). Over-glasses patching treatment is a useful option for amblyopia treatment when the patients suffer from adverse effects of using adhesive skin patching.

  8. Cross-reactions between xanthates and rubber additives.

    PubMed

    Sasseville, Denis; Al-Sowaidi, Mowza; Moreau, Linda

    2007-09-01

    We previously described allergic contact dermatitis from xanthates used in the recovery of metals from mining ores. We observed cross-reactions with carbamates, believed to be due to the common "dithio" nucleus shared by both groups. The present study was undertaken to establish the rate of cross-reactions between xanthates and rubber additives. Between November 2002 and December 2005, 1,220 consecutive patients were patch-tested with sodium isopropyl xanthate 10% in petrolatum (pet) and with potassium amyl xanthate 10% pet and later 5% pet, in addition to the North American Contact Dermatitis Group standard series and other series as required by their conditions. Fifty-one patients reacted to xanthates, carbamates, or thiurams; 26 reacted to xanthates only, and these reactions were felt to be irritant. Twenty-five patients reacted to xanthates and/or to one or more of the rubber additives, 12 had positive reactions to xanthates and to either carba mix or thiuram mix, 10 reacted to xanthates and carba mix, 9 reacted to xanthates and thiuram mix, and 8 showed positive reactions to xanthates and both mixes. However, 13 patients had positive reactions to carba mix and thiuram mix but did not react to xanthates. Six patients reacted to other rubber additives such as mercaptobenzothiazole, black rubber mix, and mixed dialkyl thioureas. Five of these patients also reacted to xanthates, 4 reacted to xanthates and carba mix, and 3 reacted to xanthates, carba mix, and thiuram mix. Of patients sensitized to carbamates, thiurams, or mercaptobenzothiazole, 50% exhibit cross-reactions with xanthates. Xanthates are irritants, and their patch-test concentrations should be lowered to 5% or less.

  9. Photocontact allergy to oxybenzone: ten years of experience.

    PubMed

    Szczurko, C; Dompmartin, A; Michel, M; Moreau, A; Leroy, D

    1994-08-01

    Intolerance of sunscreen agents has often been reported in the literature. This mainly comprises photosensitization to sunscreens such as oxybenzone. The aims of this study were to establish the incidence of photocontact allergy to oxybenzone and its relationship with the use of other cosmetics. From 1982 to 1992 we performed photopatch tests on 283 patients with suspected photodermatosis. Forty-six patients (16%) had positive reactions: 61 positive photopatch tests and 9 positive patch tests. Photocontact allergy to sunscreens was divided into 2 main groups: 35 cases to oxybenzone and 17 cases to para-aminobenzoic acid and its derivatives. Among our 35 cases of photoallergy to oxybenzone, more than one third had photoallergy to a daily moisturizer that contained oxybenzone.

  10. Observational study of changes in epidural pressure and elastance during epidural blood patch in obstetric patients.

    PubMed

    Pratt, S D; Kaczka, D W; Hess, P E

    2014-05-01

    During an epidural blood patch, we inject blood until the patient describes mild back pressure, often leading to injection of more than 20 mL of blood. We undertook this study to measure the epidural pressures generated during an epidural blood patch and to identify the impact of volume on epidural elastance in obstetric patients. This study was performed in postpartum patients who presented for an epidural blood patch with symptoms consistent with a postdural puncture headache. After identification of the epidural space using loss of resistance to air or saline, we measured static epidural pressure after each 5-mL injection of blood. Models were then fitted to the data and the epidural elastance and compliance calculated. Eighteen blood patches were performed on 17 patients. The mean final volume injected was 18.9±7.8 mL [range 6-38 mL]. The mean final pressure generated was 13.1±13.4 mmHg [range 2-56 mmHg]. A curvilinear relationship existed between volume injected and pressure, which was described by two models: (1) pressure=0.0254×(mL injected)(2)+0.0297 mL, or (2) pressure=0.0679×mL(1.742). The value for r2 was approximately 0.57 for both models. We found no correlation between the final pressure generated and the success of the epidural blood patch. We found a curvilinear relationship between the volume of blood injected during an epidural blood patch and the pressure generated in the epidural space. However, there was a large variation in both the volume of blood and the epidural pressure generated. The clinical importance of this finding is not known. A larger study would be required to demonstrate whether pressure is a predictor of success. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. The effects of patch shape and connectivity on nest site selection and reproductive success of the Indigo Bunting.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weldon, Aimee Jean

    2004-07-01

    Description – Ph.D Dissertation. North Carolina State University. Raleigh, North Carolina. 135 pp. Abatract - Habitat fragmentation and its associated effects have been blamed for the recent population declines of many Neotropical migratory bird species. Increased predation and parasitism resulting from edge-related effects have been implicated for poor nesting success in many studies, mostly of forest interior species. However, little attention has been devoted to disturbance-dependent birds. In this study, I examine how patch shape and connectivity in fragmented landscapes affects the reproductive success of disturbance-dependent bird species, specifically the Indigo Bunting (Passerina cyanea). I conducted my study in amore » landscape-scale experimental system of similar-area habitat patches that differed in connectivity and in shape. Shapes differed between edgy and rectangular forms, where edgy patches contained 50% more edge than rectangular patches. I tested whether edgy patches function as ecological traps for species with strong edge preferences, by leading them to select dangerous habitats. Indigo Buntings preferentially selected edgy patches over rectangular patches, but experienced significantly lower reproductive success in edgy patches early in the season. Although predation pressure intensified in rectangular patches late in the season, seasonal fecundity was still significantly lower in edgy patches, providing the first empirical evidence that edges can function as ecological traps for Indigo Buntings. A second objective of my study was to evaluate the efficacy of conservation corridors for disturbance-dependent bird species. Conservation corridors have become a popular strategy to preserve biodiversity and promote gene flow in fragmented landscapes, but corridors may also have negative consequences. I tested the hypothesis that corridors can increase nest predation risk in connected patches relative to unconnected patches. Nest predation rates increased significantly in connected patches compared to unconnected rectangular patches, but were similar between connected patches and unconnected edgy patches. This suggests that the increase in predator activity in connected patches is largely attributable to edge effects incurred through the addition of a corridor. This is the first landscape-scale study to experimentally demonstrate the potential negative effects of conservation corridors.« less

  12. Diclofenac patch for topical treatment of acute impact injuries: a randomised, double blind, placebo controlled, multicentre study

    PubMed Central

    Predel, H; Koll, R; Pabst, H; Dieter, R; Gallacchi, G; Giannetti, B; Bulitta, M; Heidecker, J; Mueller, E

    2004-01-01

    Objectives: To investigate the clinical efficacy and safety of a newly developed diclofenac patch in the topical treatment of blunt impact injuries. Methods: This was a randomised, placebo controlled, double blind, multicentre study in 120 patients with traumatic blunt soft tissue injury. Within 3 h of the injury participants of sport competitions and training camps were enrolled and treated twice daily with the diclofenac or a placebo patch over a period of 7 days. Patients were randomised (1:1) to two parallel groups. Tenderness produced by pressure was measured twice daily during the first 3 days after enrolment as well as at day 7. Tenderness was defined as the amount of pressure (measured by a calibrated caliper at the centre of the injury) that first produced a pain reaction as reported by the patient. Results: The primary efficacy variable was the area under the curve for tenderness over the first 3 days. The diclofenac patch was significantly more effective than placebo (p<0.0001). The treatment effect was 64.7 kp h/cm2 (95% confidence interval 48.7 to 80.9) between diclofenac and placebo patches. These results were supported by all secondary efficacy variables. The diclofenac patch produced rapid pain relief as reflected by the time to reach resolution of pain at the injured site which was significantly shorter compared to placebo (p<0.0001). The diclofenac patch was well tolerated. The most frequently observed adverse events were local cutaneous adverse reactions (pruritus, rash) of minor severity occurring with the same frequency as in the placebo group. Conclusions: A newly developed diclofenac patch is effective and safe for the treatment of blunt impact injuries. PMID:15155436

  13. Vapor Pressure and Predicted Stability of American Contact Dermatitis Society Core Allergens

    PubMed Central

    Jou, Paul C.; Siegel, Paul D.; Warshaw, Erin M.

    2018-01-01

    Background Accurate patch testing is reliant on proper preparation of patch test allergens. The stability of patch test allergens is dependent on several factors including vapor pressure (VP). Objective This investigation reviews the VP of American Contact Dermatitis Society Core Allergens and compares stability predictions based on VP with those established through clinical testing. Methods Standard references were accessed for determining VP in millimeters of mercury and associated temperature in degrees celsius. If multiple values were listed, VP at temperatures that most approximate indoor storage conditions (20°C and 25°C) were chosen. For mixes, the individual component with the highest VP was chosen as the overall VP, assuming that the most volatile substance would evaporate first. Antigens were grouped into low (≤0.001 mm Hg), moderate (<1 to >0.001 mm Hg), and high (≥1 mm Hg) volatility using arbitrary cutoff values. Conclusions This review is consistent with previously reported data on formaldehyde, acrylates, and fragrance material instability. Given lack of testing data, VP can be useful in predicting patch test compound stability. Measures such as air-tight multidose reagent containers, sealed single-application dispensers, preparation of patches immediately before application, and storage at lower temperatures may remedy some of these issues. PMID:27427821

  14. A comparison of a novel testosterone bioadhesive buccal system, striant, with a testosterone adhesive patch in hypogonadal males.

    PubMed

    Korbonits, Márta; Slawik, Marc; Cullen, Derek; Ross, Richard J; Stalla, Günter; Schneider, Harald; Reincke, Martin; Bouloux, Pierre M; Grossman, Ashley B

    2004-05-01

    A novel delivery system has been developed for testosterone replacement. This formulation, COL-1621 (Striant), a testosterone-containing buccal mucoadhesive system, has been shown in preliminary studies to replace testosterone at physiological levels when used twice daily. Therefore, the current study compared the steady-state pharmacokinetics and tolerability of the buccal system with a testosterone-containing skin patch (Andropatch or Androderm) in an international multicenter study of a group of hypogonadal men. Sixty-six patients were randomized into two groups; one applied the buccal system twice daily, whereas the other applied the transdermal patch daily, in each case for 7 d. Serum total testosterone and dihydrotestosterone concentrations were measured at d 1, 3 or 4, and 6, and serially over the last 24 h of the study. Pharmacokinetic parameters for each formulation were calculated, and the two groups were compared. The tolerability of both formulations was also evaluated. Thirty-three patients were treated with the buccal preparation, and 34 were treated with the transdermal patch. The average serum testosterone concentration over 24 h showed a mean of 18.74 nmol/liter (SD =; 5.90) in the buccal system group and 12.15 nmol/liter (SD =; 5.55) in the transdermal patch group (P < 0.01). Of the patients treated with the buccal system, 97% had average steady-state testosterone concentrations within the physiological range (10.41-36.44 nmol/liter), whereas only 56% of the transdermal patch patients achieved physiological total testosterone concentrations (P < 0.001 between groups). Testosterone concentrations were within the physiological range in the buccal system group for a significantly greater portion of the 24-h treatment period than in the transdermal patch group (mean, 84.9% vs. 54.9%; P < 0.001). Testosterone/dihydrotestosterone ratios were physiological and similar in both groups. Few patients experienced major adverse effects from either treatment. No significant local tolerability problems were noted with the buccal system, other than a single patient withdrawal. We conclude that this buccal system is superior to the transdermal patch in achieving testosterone concentrations within the normal range. It may, therefore, be a valuable addition to the range of choices for testosterone replacement therapy.

  15. Rivastigmine patch for treatment of Alzheimer's disease in clinical practice in Thailand.

    PubMed

    Kulkantrakorn, Kongkiat; Tanyakitpisal, Panas; Towanabut, Somchai; Dejthevaporn, Charungthai; Rangseekajee, Poonsri; Pongpakdee, Sunsanee; Laptikultham, Somsak; Rodprasert, Kritsada; Setthawatcharawanich, Suwanna; Thinkhamrop, Bandit

    2013-03-01

    Rivastigmine is a cholinesterase inhibitor for treatment of mild to moderate Alzheimer's disease (AD) and dementia associated with Parkinson's disease. The new patch formulation was recently made available. We assessed the safety, tolerability, and cognitive outcome of rivastigmine patch in treatment of mild to moderate AD in clinical practice in Thailand. A multicentre, hospital-based, prospective observational study was conducted in nine hospitals across Thailand. Patients with probable mild to moderate AD who received the rivastigmine patch were enrolled. Data were collected data at baseline, weeks 4-8 and after week16. A total of 116 AD patients were screened, and three were excluded. Of 113 patients, 62.8% were women with a mean age of 73.3 ± 9.2 years; 79.7% were newly diagnosed. One-third of all patients had been using antipsychotic or antidepressant medication. Common comorbidities were hypertension and dyslipidemia. The Thai Mental State Examination score significantly increased from 18.6 to 20.3 (weeks 4-8) and 20.4 (week 16+) (P < 0.001). Scores based on physicians' (Clinical Global Impression) and caregivers' (Patients' Caregiver Global Impression of Change) impressions of improvement suggested minimal improvement. Because of adverse events, seven patients's dosages were reduced 10 cm(2) to 5 cm(2) or from 5 cm(2) to nothing. Itching was the most common adverse symptom. During the first 16 weeks after initiation of rivastigmine patch therapy, patients with probable mild to moderate AD had statistically significant improvement in cognitive function, but clinically marginal benefit. Rivastigmine was safe and well tolerated. © 2012 The Authors. Psychogeriatrics © 2012 Japanese Psychogeriatric Society.

  16. From high doses of oral rivastigmine to transdermal rivastigmine patches: user experience and satisfaction among caregivers of patients with mild to moderate Alzheimer disease.

    PubMed

    Reñé, R; Ricart, J; Hernández, B

    2014-03-01

    Rivastigmine, a treatment for mild to moderate Alzheimer disease (AD), is the first cholinesterase inhibitor to be available in the transdermal format. We aim to describe user experience and satisfaction with the rivastigmine patch, as well as any clinical changes perceived in patients. Observational, cross-sectional, multicentre study with 239 investigators and 1851 informal caregivers of patients with mild to moderate AD. Patients were treated with transdermal rivastigmine patches for ≥ 6 months and had previously received high doses of oral rivastigmine. Mean caregiver age was 59.8±14.4 years and 70.9% were women. They spent 10.0±7.1hours per day providing care and 79.8% lived with the patient. Patch instructions were described as easy to follow by 97.1% of the caregivers and 92.1% of them rated patch application as easy or very easy. The most commonly cited disadvantage was adhesion problems (26.8%). Discontinuation of treatment was due to cutaneous reactions in most cases. Overall, 76.5% of the caregivers were satisfied or very satisfied with transdermal treatment and 77.4% considered that its interference with daily activities was minimal or null. The patch was preferred to oral treatment by 94.3% of caregivers. Clinical Global Impression of Change ratings improved according to 61.3% of the caregivers and 53% of the investigators. Few caregivers reported medication forgetfulness. Most caregivers of patients with mild to moderate AD preferred the transdermal format of rivastigmine to the oral format. Caregivers also reported overall satisfaction, ease of use, and reduced impact on daily activities for transdermal rivastigmine format, in addition to patient improvement compared to their condition under the previous treatment. Copyright © 2012 Sociedad Española de Neurología. Published by Elsevier Espana. All rights reserved.

  17. Diagnosing Allergic Contact Dermatitis Through Elimination, Perception, Detection and Deduction.

    PubMed

    Pongpairoj, Korbkarn; Puangpet, Pailin; Thaiwat, Supitchaya; McFadden, John P

    2017-10-01

    Several authors have commented upon the skills of detection required in making a diagnosis of allergic contact dermatitis. Here, we emphasise the search for clues in a systematic manner. We describe four stages as part of a systematic method for diagnosing allergic contact dermatitis. Firstly, elimination (or inclusion) of non-allergic diagnoses. Secondly, perception: the pre-patch test diagnosis and the 'three scenarios' principle. Thirdly, detection: optimising the sensitivity of the patch test process. Fourthly, deduction: diagnosing allergic contact dermatitis by associating the dermatitis with the allergen exposure. We further compare and contrast the pre-patch test history and examination with the markedly different one ('microhistory' and 'microexamination') used after patch testing. The importance of knowledge of contact dermatitis literature is emphasised with a review of recent publications. Finally, we also highlight the use of contact allergy profiling as an investigative tool in the diagnosis of allergic contact dermatitis.

  18. Insulin autoimmune syndrome caused by an adhesive skin patch containing loxoprofen-sodium.

    PubMed

    Okazaki-Sakai, Satoko; Yoshimoto, Sachiko; Yagi, Kunimasa; Wakasugi, Takanobu; Takeda, Yoshiyu; Yamagishi, Masakazu

    2013-01-01

    A 62-year-old woman complained of repeated hypoglycemic events. A 75 g oral glucose tolerance test (75 gOGTT) showed a marked increase in the plasma insulin level and impaired glucose tolerance. The patient exhibited a high titer of plasma anti-insulin autoantibodies. Her diagnosis was insulin autoimmune syndrome (IAS). Following the cessation of loxoprofen-sodium (LOXs), she experienced no further hypoglycemic episodes. However, the hypoglycemic attacks recurred following the accidental readministration of LOXs in an adhesive skin patch. Considering the changes in the titer of anti-insulin autoantibodies, the repeated 75 gOGTT and the repeated Scatchard analysis, we determined LOXs to be the cause of the IAS and evaluated the characteristics of the autoantibodies.

  19. Noninvasive measuring methods for the investigation of irritant patch test reactions. A study of patients with hand eczema, atopic dermatitis and controls.

    PubMed

    Agner, T

    1992-01-01

    The aim of the study was to assess the susceptibility of clinically normal skin to a standard irritant trauma under varying physiological and patophysiological conditions. Evaluation of skin responses to patch tests with sodium lauryl sulphate (SLS) was used for assessment of skin susceptibility. The following noninvasive measuring methods were used for evaluation of the skin before and after exposure to irritants: measurement of transepidermal water loss by an evaporimeter, measurement of electrical conductance by a hydrometer, measurement of skin blood flow by laser Doppler flowmetry, measurement of skin colour by a colorimeter and measurement of skin thickness by ultrasound A-scan. The studies were carried out on healthy volunteers and patients with eczema. In the first studies the standard irritant patch test for assessment of skin susceptibility was characterized and validated. SLS was chosen among other irritants because of its ability to penetrate and impair the skin barrier. The implications of use of different qualities of SLS was investigated. The applied noninvasive measuring methods were evaluated, and for quantification of SLS-induced skin damage measurement of TEWL was found to be the most sensitive method. Application of the standard test on clinically normal skin under varying physiological and patophysiological conditions lead to the following main results: Seasonal variation in skin susceptibility to SLS was found, with increased susceptibility in winter, when the hydration state of the stratum corneum was also found to be decreased. A variation in skin reactivity to SLS during the menstrual cycle was demonstrated, with an increased skin response at day 1 as compared to days 9-11 in the menstrual cycle. The presence of active eczema distant from the test site increased skin susceptibility to SLS, indicating a generalized hyperreactivity of the skin. Taking these sources of variation into account healthy volunteers and patients with hand eczema and atopic dermatits were studied and compared. In healthy volunteers increased baseline TEWL and increased light reflection from the skin, interpreted as "fair" skin, was found to be associated with increased susceptibility to SLS. Hand eczema patients were found to have fairer and thinner skin than matched controls. Increased susceptibility to SLS was found only in patients with acute eczema. Patients with atopic dermatitis had increased baseline TEWL as well as increased skin susceptibility as compared to controls. Skin susceptibility is thus influenced by individual- as well as environment-related factors. Knowledge of determinants of skin susceptibility may be useful for the identification of high-risk subjects for development of irritant contact dermatitis, and may help to prevent the formation of the disease.

  20. Transdermal Scopolamine and Acute Postoperative Urinary Retention in Pelvic Reconstructive Surgery.

    PubMed

    Propst, Katie; OʼSullivan, David M; Tulikangas, Paul K

    2016-01-01

    To evaluate the relationship between perioperative use of transdermal scopolamine and the rate of urinary retention after stress urinary incontinence and pelvic organ prolapse procedures in women. This is a retrospective, cohort study; the primary outcome is the rate of acute postoperative urinary retention. Study candidates were adult female patients who underwent pelvic reconstructive surgery at a tertiary care center. Subjects were excluded if preoperative postvoid residual urine volume was greater than 150 mL, preoperative urodynamic testing was not performed, or if a postoperative trial of void was not performed. Subjects were grouped based on preoperative use of transdermal scopolamine. Patients were selected consecutively until 138 subjects per group was reached. Differences in rates of acute postoperative urinary retention were evaluated using a chi-square test. Group demographics were evaluated using t tests and χ tests. Two hundred seventy-six subjects were included in the analysis, 138 received a transdermal scopolamine patch in the perioperative period and 138 did not. The overall rate of acute postoperative urinary retention was 25.3%. There was no significant difference in the rate of acute postoperative urinary retention between the study groups (scopolamine, 26.8%; no scopolamine, 23.9%; P = 0.580). Demographics of the 2 groups were compared; patients who received scopolamine patch were younger (P = 0.001), received a greater amount of intravenous fluids (P = 0.007), and underwent a greater percentage of incontinence procedures (P = 0.048). Otherwise, there were no differences between the groups. Transdermal scopolamine is not a risk factor for acute postoperative urinary retention after pelvic reconstructive procedures.

  1. Immunophenotyping of the cutaneous cellular infiltrate after atopy patch testing in cats with atopic dermatitis.

    PubMed

    Roosje, P J; Thepen, T; Rutten, V P M G; van den Brom, W E; Bruijnzeel-Koomen, C A F M; Willemse, T

    2004-10-01

    Cats with spontaneously occurring atopic dermatitis have clinical and immunocytochemical characteristics compatible with these in humans with atopic dermatitis (AD). The atopy patch test (APT) has proven to be a valuable tool in elucidating the disease process in humans. Additionally, the APT is very specific and bypasses the problem of conflicting results due to differences in chronicity of lesions of AD patients. We adapted the APT for use in cats to explore the suitability of the APT as a tool to study the onset of allergic inflammation in cats with atopic dermatitis. APT were performed in AD cats (n = 6) and healthy cats (n = 10). All cats were patch tested with two allergens in three different dilutions and a diluent control. The allergens for the APT were selected from positive intradermal test and /or prick test results and consisted of: Dermatophagoides farinae, D. pteronyssinus, Tyrophagus putrescentiae, and a grass pollen mixture. APT were read after 10, 24 and 48 h, and punch biopsies for immunohistochemical evaluation were collected at these time points. Macroscopically positive APT reactions were observed in three out of six cats at 24 and/or 48 h with allergen concentrations of 25,000 and 100,000 NU/ml. Reactions were not observed at negative control sites and neither in control animals. A significantly increased number of IL-4+, CD4+, CD3+, MHC class II+ and CD1a+ cells was found in one AD cat with positive APT reactions. Five out of six AD cats had significantly increased IL-4+ T cell numbers at 24 and/or 48 h. Our data indicate that in cats, macroscopically positive patch test reactions can be induced, which have a cellular infiltrate similar to that in lesional skin. We found a high specificity and a macroscopically positive APT reaction in half of the cats, which is similar to what is seen in humans. Hence, the APT in cats might be a useful tool in studying the immunopathogenesis of feline atopic dermatitis.

  2. Rivastigmine transdermal patch and capsule in Alzheimer's disease: influence of disease stage on response to therapy.

    PubMed

    Farlow, Martin R; Grossberg, George T; Meng, Xiangyi; Olin, Jason; Somogyi, Monique

    2011-12-01

    The cholinesterase inhibitor rivastigmine is approved for the symptomatic treatment of mild to moderate Alzheimer's disease (AD). This exploratory, hypothesis-forming analysis assessed response to rivastigmine according to severity of dementia at baseline. This was a retrospective analysis of a large randomized, placebo-controlled trial (ENA713D2320). AD patients treated with 9.5 mg/24 h rivastigmine patch, 17.4 mg/24 h rivastigmine patch, rivastigmine capsule (12 mg/day), or placebo were stratified according to baseline Mini-Mental State Examination (MMSE) scores: ≥7 to ≤12 (severe disease), ≥13 to ≤15 (moderately severe), ≥16 to ≤18 (moderate), or ≥19 to ≤25 (mild to moderate). Changes from baseline at Week 24 on Alzheimer's Disease Assessment Scale-cognitive subscale (ADAS-cog), Alzheimer's Disease Cooperative Study-Clinical Global Impression of Change (ADCS-CGIC), and Alzheimer's Disease Cooperative Study-Activities of Daily Living (ADCS-ADL) were assessed. Based on baseline MMSE scores, 141, 228, 333, and 348 patients had severe, moderately severe, moderate, and mild to moderate dementia. Worsening of ADAS-cog, ADCS-CGIC, and ADCS-ADL scores in patients receiving placebo were greater in patients with more severe dementia. Significant improvements versus placebo were seen with rivastigmine patch and/or capsule on ADAS-cog, ADCS-CGIC, and ADCS-ADL scores in patients with severe, moderately severe, and moderate AD (all p < 0.05). However, no significant improvements were seen in rivastigmine-treated patients with mild to moderate AD. Rivastigmine benefits AD patients across dementia stages. Similar to previous cholinesterase inhibitor studies, greatest treatment effects with rivastigmine patch and capsule were seen in patients with more advanced dementia, most likely driven by greater placebo decline in this population. Copyright © 2010 John Wiley & Sons, Ltd.

  3. Is Patch Testing with Food Additives Useful in Children with Atopic Eczema?

    PubMed

    Catli, Gonul; Bostanci, Ilknur; Ozmen, Serap; Dibek Misirlioglu, Emine; Duman, Handan; Ertan, Ulker

    2015-01-01

    Atopy patch testing is a useful way to determine delayed-type hypersensitivity reactions to foods and aeroallergens. Although food additives have been accused of worsening atopic eczema symptoms, according to recent studies the role of food additives in atopic eczema remains unclear. The purpose of our study was to investigate food additive hypersensitivity in a group of children with atopic eczema by using standardized atopy patch testing and to determine the role of food additive hypersensitivity in atopic eczema. Thirty-four children with atopic eczema and 33 healthy children were enrolled in the study. Children who consumed foods containing additives and did not use either antihistamines or local or systemic corticosteroids for at least 7 days prior to admission were enrolled in the study. All children were subjected to atopy patch testing and after 48 and 72 hours their skin reactions were evaluated by using the guidelines. Positive atopy patch test results were significantly higher in the atopic eczema group. Forty-one percent of the atopic eczema group (n = 14) and 15.2% (n = 5) of the control group had positive atopy patch test results with food additives (p = 0.036) (estimated relative risk 1.68, case odds 0.7, control odds 0.17). Carmine hypersensitivity and the consumption of foods containing carmine, such as gumdrops, salami, and sausage, were significantly higher in the children with atopic eczema. This is the first study investigating hypersensitivity to food additives in children with atopic eczema. Our results indicate that carmine may play a role in atopic eczema. © 2015 Wiley Periodicals, Inc.

  4. Contact Allergy Cross-reactions: Retrospective Clinical Data and Review of the Literature.

    PubMed

    Scheman, Andrew; Hipolito, Ricky; Severson, David; Youkhanis, Nineveh

    We discuss cross-reactions that can occur when a patient allergic to a specific allergen also reacts to a similar allergen. Currently, The American Contact Dermatitis Society Contact Allergy Management Program, which allows physicians to identify safe products for their patients, uses a 10% threshold to distinguish significant cross-reactors. New clinical data from a patch testing center along with previous data in the literature are analyzed to help determine whether current cross-reactor definitions are reasonable or should be altered.

  5. Acrylate-induced allergic contact dermatitis in a car windscreen repairer.

    PubMed

    Fremlin, G; Sansom, J

    2014-10-01

    We report a case of an allergic skin reaction to ultraviolet-cured acrylates in a windscreen repair worker. The patient presented with a 6 month history of fingertip dryness, vesicles and desquamation. He had worked as a self-employed car windscreen repairer for 19 years. Previous management with vinyl glove protection and treatment with clobetasol propionate ointment had produced little improvement. He was patch tested to the British Society for Cutaneous Allergy standard and preservatives series and to the two acrylates used in his work environment, identified using safety data sheets, methyl methacrylate 2% pet and 2-hydroxyethylmethacrylate (2-HEMA) 2% pet. A positive reaction was seen at Day 4 to 2-HEMA, but all other patch tests were negative. An occupational allergic contact dermatitis to 2-HEMA was diagnosed. The patient was given avoidance advice and advised to use nitrile gloves. Although he was unable to give up his current work, he has continued his job using nitrile gloves with marked improvement. © The Author 2014. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. Cosmetic allergy: incidence, diagnosis, and management.

    PubMed

    Orton, David I; Wilkinson, John D

    2004-01-01

    A recent epidemiologic survey in the UK revealed that 23% of women and 13.8% of men experience some sort of adverse reaction to a personal care product over the course of a year. Although most of these reactions may be due to subjective sensory irritation, various studies reveal that up to 10% of dermatologic patients who are patch tested are allergic to cosmetic products or their constituent ingredients. Causative products include deodorants and perfumes, skin care products, hair care products, and nail cosmetics. Allergic contact dermatitis mainly results from fragrance chemicals and preservatives. Recent work has suggested that additional fragrance chemicals may need to be tested in order to identify those patients 'missed' by the current fragrance mix; in particular, hydroxy-isohexyl-3-cyclohexene carboxaldehyde (HMPPC Lyral) has been singled out as an important sensitizing agent. The increased usage of natural fragrances and botanic extracts can also cause problems in their own right or through co-reactivity. The preservative methyldibromo glutaronitrile has also been recognized as an increasingly important sensitizer in Europe, which has led to the recent recommendation that it should be prohibited from 'leave-on' products until information on 'safe' consumer levels becomes available. Other emerging allergens include UV filters, tosylamide/formaldehyde resin, and nail acrylates. The diagnosis of cosmetic allergy should be confirmed with patch testing, including testing of 'whole' products, when necessary, and repeat open application tests can be used to confirm the relevance of reactions in cases of doubt.

  7. Lateral interactions and speed of information processing in highly functioning multiple sclerosis patients.

    PubMed

    Nagy, Helga; Bencsik, Krisztina; Rajda, Cecília; Benedek, Krisztina; Janáky, Márta; Beniczky, Sándor; Kéri, Szabolcs; Vécsei, László

    2007-06-01

    Visual impairment is a common feature of multiple sclerosis. The aim of this study was to investigate lateral interactions in the visual cortex of highly functioning patients with multiple sclerosis and to compare that with basic visual and neuropsychologic functions. Twenty-two young, visually unimpaired multiple sclerosis patients with minimal symptoms (Expanded Disability Status Scale <2) and 30 healthy controls subjects participated in the study. Lateral interactions were investigated with the flanker task, during which participants were asked to detect the orientation of a low-contrast Gabor patch (vertical or horizontal), flanked with 2 collinear or orthogonal Gabor patches. Stimulus exposure time was 40, 60, 80, and 100 ms. Digit span forward/backward, digit symbol, verbal fluency, and California Verbal Learning Test procedures were used for background neuropsychologic assessment. Results revealed that patients with multiple sclerosis showed intact visual contrast sensitivity and neuropsychologic functions, whereas orientation detection in the orthogonal condition was significantly impaired. At 40-ms exposure time, collinear flankers facilitated the orientation detection performance of the patients resulting in normal performance. In conclusion, the detection of briefly presented, low-contrast visual stimuli was selectively impaired in multiple sclerosis. Lateral interactions between target and flankers robustly facilitated target detection in the patient group.

  8. Patch-Augmented Rotator Cuff Repair and Superior Capsule Reconstruction

    PubMed Central

    Petri, M.; Greenspoon, J.A.; Moulton, S.G.; Millett, P.J.

    2016-01-01

    Background: Massive rotator cuff tears in active patients with minimal glenohumeral arthritis remain a particular challenge for the treating surgeon. Methods: A selective literature search was performed and personal surgical experiences are reported. Results: For patients with irreparable rotator cuff tears, a reverse shoulder arthroplasty or a tendon transfer are often performed. However, both procedures have rather high complication rates and debatable long-term results, particularly in younger patients. Therefore, patch-augmented rotator cuff repair or superior capsule reconstruction (SCR) have been recently developed as arthroscopically applicable treatment options, with promising biomechanical and early clinical results. Conclusion: For younger patients with irreparable rotator cuff tears wishing to avoid tendon transfers or reverse total shoulder arthroplasty, both patch-augmentation and SCR represent treatment options that may delay the need for more invasive surgery. PMID:27708733

  9. Effectiveness of the addition of citicoline to patching in the treatment of amblyopia around visual maturity: A randomized controlled trial

    PubMed Central

    Pawar, Prachee Vasant; Mumbare, Sachin S; Patil, Mrunal Suresh; Ramakrishnan, Seema

    2014-01-01

    Aim: To study the effectiveness of the addition of citicoline to patching in the treatment of amblyopia in the age group of 4-13 years. Materials and Methods: A randomized controlled trial, which included patients who were randomly divided into two groups. Both the groups received patching therapy till plateau was achieved in phase 1 of the study. Then in phase 2, group I received citicoline plus patching and group II continued to receive only patching. Outcome Measures: Outcome was measured by the visual acuity in logMAR every month in phase 1 till plateau was achieved and then for 12 months in phase 2. Results: No significant difference was found in the mean visual acuities in these two groups in phase 1 till plateau was reached. In phase 2, for the initial four months, there was no significant difference in the visual acuities in these two groups, at the respective intervals. However, five months onward, up to 12 months, there was a significant difference in the visual acuities in these groups. The result was the same in younger patients (< seven years of age) as well as in older patients (> seven years of age). In phase 2, the mean proportional improvement in group I was significantly more than that in group II, at two months and onward, at the respective intervals. Conclusion: The improvement in visual acuity with citicoline plus patching was significantly more than that with patching alone, in one year of treatment. PMID:24618483

  10. Content and reactivity to product perfumes in fragrance mix positive and negative eczema patients. A study of perfumes used in toiletries and skin-care products.

    PubMed

    Johansen, J D; Rastogi, S C; Andersen, K E; Menné, T

    1997-06-01

    The aim of the study was to investigate the elicitation potential of perfumes from 17 commonly sold lower-price cosmetic products. 8 of the perfumes were from stay-on cosmetics and 9 were from wash-off cosmetics. Each perfume was tested in 500 consecutive eczema patients, who also were tested with the European standard patch test series. 4.2% reacted to 1 or more of the wash-off product perfumes and 3.2% to 1 or more of the stay-on product perfumes. Concordant positive reactions between the fragrance mix and the product perfumes were found in 81.3% of positive reactions to the stay-on product perfumes and in 52.4% of the reactions to the wash-off product perfumes. Compared to the fragrance mix alone, only 1 additional case of contact allergy to the product perfumes was detected by balsam of Peru. Chemical analysis revealed that between 1 and 5 of the chemically-defined constituents of the fragrance mix were present in all of the product perfumes. Geraniol was found in 12 of the 17 perfumes and was most often detected. The concentration of the target fragrance materials ranged from 0.005%-1.35 w/v%. It is concluded that the allergenic constituents of the fragrance mix are impossible to avoid if perfumed cosmetics are used. Furthermore, patients suspected of perfume allergy need to be tested with their own perfumed products, as far from all cases of perfume allergy are detected by the fragrance mix and/or balsam of Peru in the European standard patch test series.

  11. A 24-Week, Randomized, Controlled Trial of Rivastigmine Patch 13.3 mg/24 h Versus 4.6 mg/24 h in Severe Alzheimer's Dementia

    PubMed Central

    Farlow, Martin R; Grossberg, George T; Sadowsky, Carl H; Meng, Xiangyi; Somogyi, Monique

    2013-01-01

    Aims The 24-week, prospective, randomized, double-blind ACTION study investigated the efficacy, safety, and tolerability of 13.3 versus 4.6 mg/24 h rivastigmine patch in patients with severe Alzheimer's disease (AD). Methods Patients had probable AD and Mini–Mental State Examination scores ≥3–≤12. Primary outcome measures were as follows: Severe Impairment Battery (SIB) and AD Cooperative Study–Activities of Daily Living scale–Severe Impairment Version (ADCS-ADL-SIV). Secondary outcomes were as follows: ADCS-Clinical Global Impression of Change (ADCS-CGIC), 12-item Neuropsychiatric Inventory (NPI-12), and safety/tolerability. Results Of 1014 patients screened, 716 were randomized to 13.3 mg/24 h (N = 356) or 4.6 mg/24 h (N = 360) patch. Baseline characteristics/demographics were comparable. Completion rates were as follows: 64.3% (N = 229) with 13.3 mg/24 h and 65.0% (N = 234) with 4.6 mg/24 h patch. The 13.3 mg/24 h patch was significantly superior to 4.6 mg/24 h patch on cognition (SIB) and function (ADCS-ADL-SIV) at Week 16 (P < 0.0001 and P = 0.049, respectively) and 24 (primary endpoint; P < 0.0001 and P = 0.025). Significant between-group differences (Week 24) were observed on the ADCS-CGIC (P = 0.0023), not NPI-12 (P = 0.1437). A similar proportion of the 13.3 mg/24 h and 4.6 mg/24 h patch groups reported adverse events (AEs; 74.6% and 73.3%, respectively) and serious AEs (14.9% and 13.6%). Conclusions The 13.3 mg/24 h patch demonstrated superior efficacy to 4.6 mg/24 h patch on SIB and ADCS-ADL-SIV, without marked increase in AEs, suggesting higher-dose patch has a favorable benefit-to-risk profile in severe AD. PMID:23924050

  12. Rotigotine Transdermal Patch: A Review in Restless Legs Syndrome.

    PubMed

    Garnock-Jones, Karly P

    2016-07-01

    Rotigotine transdermal patch (Leganto(®), Neupro(®)) is indicated for the treatment of restless legs syndrome (RLS); this article reviews the pharmacological properties of rotigotine transdermal patch and its clinical efficacy and tolerability in patients with RLS. The transdermal patch allows for a continuous, stable release of rotigotine (avoiding first-pass metabolism), which in turn leads to continuous receptor stimulation, believed to closely mimic physiological striatal dopamine receptor function. In short-term and 6-month studies, especially at the higher dosages of 2 and 3 mg/24 h, rotigotine transdermal patch was generally associated with a significantly greater improvement in IRLS total score and CGI-S total score than placebo, and rotigotine recipients were generally more likely to respond to treatment and enter remission. In noncomparative extension studies, efficacy was sustained for ≤5 years. Rotigotine transdermal patch is generally well tolerated, and appears to have a tolerability profile that is similar to that of other non-ergolinic dopamine-receptor agonists. The most common adverse events in clinical trials included application-site reactions, nausea, headache and asthenic conditions. The drug has a relatively low risk of clinically significant augmentation of restless legs syndrome symptoms. In conclusion, rotigotine transdermal patch offers continuous administration of the drug in a daily treatment, and is a useful treatment option in patients with RLS.

  13. Irritancy potential of 17 detergents used commonly by the Indian household.

    PubMed

    Austoria, A J; Lakshmi, Chembolli; Srinivas, C R; Anand, C V; Mathew, A C

    2010-01-01

    Detergents are used by almost every household in the developed and developing world. Soap and most detergents are anionic surfactants and attack the horny layer of the skin and increase its permeability with little or no inflammatory change and may result in hand eczema, which is very distressing and incapacitating. To evaluate the irritant potential of common household detergents (laundry and dish wash) used by the Indian population using a 24-hour patch test and to convincingly educate the patients on the detergents less likely to cause irritation in the particular individual. Seventeen commonly used detergents found in Indian market were included in the study, of which, 12 were laundry detergents (powders--seven, bar soap--five) and five were dish wash detergents (powder--one, liquid--one, bar soap--three). The irritant potential of the 17 detergents were evaluated in 30 volunteers. Thirty microliters of each of the detergent bar solutions, distilled water (negative control), and 20% SDS (positive control) were applied to Finn chambers with a micropipette and occluded for 24 hours. Erythema, scaling, and edema were graded in comparison to the reaction at the negative control site (distilled water) for each volunteer separately. The scoring of erythema/dryness and wrinkling on a 0-4 point scale and edema on another 0-4 point scale was based on the Draize scale. The pH of each of the detergent solutions was determined using litmus papers (Indikrom papers from Qualigens fine chemicals). The difference between detergents (F value) was significant for erythema/dryness and wrinkling (F = 3.374; p = 0.000), but not significant for edema (F = 1.297; p = 0.194). [Table 2] lists the means for erythema/dryness and wrinkling, and edema. The F value of the totals of the means for erythema/dryness and wrinkling and edema was significant (F = 2.495; p = 0.001). The pH of all the detergents was found to be alkaline except Pril utensil cleaner which tested acidic (pH 6). The positive control, 20% SDS also tested acidic (pH 6). Similar to patch testing in allergic contact dermatitis, 24-hour patch testing with detergent solutions (8% w/v), will educate the patient on what detergent to avoid. This may bring down the total medication requirement and frequent hospital consultations for these patients.

  14. A study of tensile residual strength of composite laminates under different patch-repaired series

    NASA Astrophysics Data System (ADS)

    Ding, M. H.; zhan, S.; Tang, Y. H.; Wang, L.; Ma, D. Q.; Wang, R. G.

    2017-09-01

    The tensile behavior of composite laminate structures repaired by bonding external patches was studied in the paper. Two different types of patches including wedge patches and inverted wedge patches were used and failure mechanisms, failure load and strength predictions were studied. A convenient and fast method of building 2-D finite element modeling (FEM) of laminate structure repaired was proposed and the strength of repaired laminate structures was calculated by FEM. The results showed that more than 80% tensile strength of the undamaged laminate could be recovered by bonding patch repairs. Moreover, the results indicated that the strength of inverted wedge patches repair were higher than that of wedge patches repair. FEM simulation results indicated that high stress concentration was found along the edges of invert patches and the most weakness part located in the adhesive bondline. FEM analysis results showed that the strength predicted matched well with the test strength.

  15. Treatment of complex regional pain syndrome type 1 in a pediatric patient using the lidocaine patch 5%: a case report☆

    PubMed Central

    Frost, Steven G

    2003-01-01

    Background Successful treatment of complex regional pain syndrome type 1 (CRPS-1) requires a coordinated, multidisciplinary approach. Physical rehabilitation is an important component of long-term treatment. Unfortunately, patients with significant allodynia or hyperalgesia characteristic of CRPS-1 often have difficulty progressing through a physical therapy (PT) regimen. In most adults with CRPS-1, the treatment of choice is PO opioids. Objective This article presents a case report of the use of the lidocaine patch 5%, a targeted peripheral analgesic, in a pediatric patient and its effects on reducing pain, improving the patient's overall attitude, and facilitating compliance with ongoing PT. Results A 10-year-old girl developed CRPS-1 after arthroscopic surgery for a sprained ankle. Attempts at PT were unsuccessful due to inadequate pain relief from various treatment modalities. Therapy with the lidocaine patch 5% was initiated and resulted in significant pain relief, improvements in the patient's attitude, and progress with PT. Conclusion This case report of a child with CRPS-1 showed that therapy with lidocaine patch 5% may be efficacious in treating children with pain resulting from CRPS-1, thereby increasing the success of PT. PMID:24944409

  16. Diagnostic accuracy of patch test in children with food allergy.

    PubMed

    Caglayan Sozmen, Sule; Povesi Dascola, Carlotta; Gioia, Edoardo; Mastrorilli, Carla; Rizzuti, Laura; Caffarelli, Carlo

    2015-08-01

    The gold standard test for confirming whether a child has clinical hypersensitivity reactions to foods is the oral food challenge. Therefore, there is increasing interest in simpler diagnostic markers of food allergy, especially in children, to avoid oral food challenge. The goal of this study was to assess the diagnostic accuracy of atopy patch test in comparison with oral food challenge. We investigated 243 children (mean age, 51 months) referred for evaluation of suspected egg or cow's milk allergy. Skin prick test and atopy patch test were carried out, and after a 2 weeks elimination diet, oral food challenge was performed. Two hundred and forty-three children underwent OFC to the suspected food. We found clinically relevant food allergies in 40 (65%) children to egg and in 22 (35%) to cow's milk. The sensitivity of skin prick test for both milk and egg was 92%, specificity 91%, positive predictive value 35%, and negative predictive value of 93%. Sensitivity, specificity, positive predictive value, and negative predictive value of atopy patch test for both milk and egg were 21%, 73%, 20%, and 74%, respectively. Our study suggests that there is insufficient evidence for the routine use of atopy patch test for the evaluation of egg and cow's milk allergy. OFC remains gold standard for the diagnosis of egg and milk allergy even in the presence of high costs in terms of both time and risks during application. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. The LeucoPatch® system in the management of hard-to-heal diabetic foot ulcers: study protocol for a randomised controlled trial.

    PubMed

    Game, Frances; Jeffcoate, William; Tarnow, Lise; Day, Florence; Fitzsimmons, Deborah; Jacobsen, Judith

    2017-10-10

    Diabetic foot ulcers are a common and severe complication of diabetes mellitus. Standard treatment includes debridement, offloading, management of infection and revascularisation where appropriate, although healing times may be long. The LeucoPatch® device is used to generate an autologous platelet-rich fibrin and leucocyte wound dressing produced from the patient's own venous blood by centrifugation, but without the addition of any reagents. The final product comprises a thin, circular patch composed predominantly of fibrin together with living platelets and leucocytes. Promising results have been obtained in non-controlled studies this system, but this now needs to be tested in a randomised controlled trial (RCT). If confirmed, the LeucoPatch® may become an important new tool in the armamentarium in the management of diabetic foot ulcers which are hard-to-heal. People with diabetes and hard-to-heal ulcers of the foot will receive either pre-specified good standard care or good standard care supplemented by the application of the LeucoPatch® device. The primary outcome will be the percentage of ulcers healed within 20 weeks. Healing will be defined as complete epithelialisation without discharge that is maintained for 4 weeks and is confirmed by an observer blind to randomisation group. Ulcers of the foot are a major source of morbidity to patients with diabetes and costs to health care economies. The study population is designed to be as inclusive as possible with the aim of maximising the external validity of any findings. The primary outcome measure is healing within 20 weeks of randomisation and the trial also includes a number of secondary outcome measures. Among these are rate of change in ulcer area as a predictor of the likelihood of eventual healing, minor and major amputation of the target limb, the incidence of infection and quality of life. International Standard Randomised Controlled Trial, ISRCTN27665670 . Registered on 5 July 2013.

  18. Respiratory distress after surgery of RVOT pathologies: a word of caution on pseudoaneurysm development.

    PubMed

    Antal, A Donmez; Cikirikcioglu, M; Myers, P O; Didier, D; Kalangos, A

    2010-09-01

    Pseudoaneurysm of the right ventricle outflow tract (RVOT) is a rare complication in pediatric cardiac surgery. We report a patient who developed a right ventricular pseudoaneurysm 8 months after RVOT enlargement using a pericardial patch for infundibular pulmonary stenosis. Our patient was born with severe pulmonary valvular stenosis and treated with percutaneous balloon valvotomy in the neonatal period. Six months later, she developed infundibular pulmonary stenosis, which required surgical resection of right ventricle infundibular trabeculations and bovine pericardial patch enlargement. The postoperative period was normal. She was readmitted to hospital 5 months later complaining of wheezing, coughing and shortness of breath. Echocardiography showed a huge aneurysmal dilatation of the outflow patch in connection with the right ventricular cavity. The patient underwent resection of the pseudoaneurysm and former patch, followed by interposition of a bovine jugular vein conduit between the RVOT and pulmonary bifurcation. The early postoperative period was uncomplicated. On echocardiography, no significant residual gradient was measured through the conduit and there was no insufficiency of the valve. RVOT reconstruction with patch enlargement, homograft or conduit implantation can be the origin of pseudoaneurysms. Although their incidence is rare, they are often asymptomatic before becoming quite large and causing compression symptoms as in our patient with respiratory complaints due to airway compression. It is important to follow up these patients closely, especially in the first year after surgery since most aneurysms develop within 6 months of surgery. Georg Thieme Verlag KG Stuttgart, New York.

  19. Standardizing the Delivery of 20 μL of Hapten During Patch Testing.

    PubMed

    Selvick, Annika; Stauss, Kari; Strobush, Katrina; Taylor, Lauren; Picard, Alexandra; Doll, Andrea; Reeder, Margo

    2016-01-01

    The current method for patch test tray assembly requires hand dispensing a small volume of hapten onto chambers. Because of human error, this technique produces inaccurate and inconsistent results. The recommended volume of hapten for patch testing using Finn Chambers is 20 μL. The aims of this study were to create a device that standardizes the delivery of 20 μL and to compare it with the current hand dispensing technique. A device, named the Revolution, was created using the SolidWorks program. Five nurses in our Contact Dermatitis Clinic were asked to load 10 Finn Chambers using the current technique and also using the Revolution. Assembly time, volume of petrolatum, and accuracy of placement were measured. After the 3 trials, the nurses completed a survey on the 2 methods. The amount of petrolatum dispensed using the current technique ranged from 16 to 85 μL, with an average amount of 41.39 μL. The Revolution design dispensed an average of 19.78 μL. The current hand dispensing technique does not allow for accurate and consistent dispensing of 20 μL for patch testing. In contrast, the Revolution is an accurate and consistent device that can help standardize the patch testing method.

  20. [Evaluation of eye patching after cataract surgery in topical anesthesia].

    PubMed

    Mayer, S; Wirbelauer, C; Häberle, H; Altmeyer, M; Pham, D T

    2005-01-01

    Although postoperative eye patching is a common practice its background is not well known. Therefore the necessity of eye patching after cataract surgery in topical anesthesia from the medical point of view and the patients' subjective opinion was studied. In this prospective and randomized study 133 patients received after cataract surgery either no covering of the eye (group1), a transparent eye shield for four hours (group 2), an eye pad for four hours (group 3) or an eye pad until the next morning (group 4). Clinical findings were noted and local symptoms, such as pain, foreign body sensation, tearing and photophobia were documented on a visual analogue scale (0 - 10). Furthermore, a questionnaire concerning the subjective opinion was handed out to the patient. The clinical findings revealed no significant differences between the groups. The mean values for local pain were 0.94 +/- 1.56, for the foreign body sensation 1.41 +/- 2.02, for tearing 0.99 +/- 1.8 and for photophobia 1.05 +/- 1.99. Comparing the groups there was significantly more pain and foreign body sensation reported by the patients in group 3, who received eye patching for 4 hours. 91 % of the unpatched patients had no discomfort, whereas 53 % of the patients wearing an eye pad until the next morning considered it as unnecessary. After cataract surgery in topical anesthesia only mild symptoms were noted. There were no significant differences between the groups in the objective clinical findings and the subjective feeling. These results indicate that after cataract surgery eye patching could be unnecessary.

  1. Testing a bioenergetics-based habitat choice model: bluegill (Lepomis macrochirus) responses to food availability and temperature

    USGS Publications Warehouse

    2011-01-01

    Using an automated shuttlebox system, we conducted patch choice experiments with 32, 8–12 g bluegill sunfish (Lepomis macrochirus) to test a behavioral energetics hypothesis of habitat choice. When patch temperature and food levels were held constant within patches but different between patches, we expected bluegill to choose patches that maximized growth based on the bioenergetic integration of food and temperature as predicted by a bioenergetics model. Alternative hypotheses were that bluegill may choose patches based only on food (optimal foraging) or temperature (behavioral thermoregulation). The behavioral energetics hypothesis was not a good predictor of short-term (from minutes to weeks) patch choice by bluegill; the behavioral thermoregulation hypothesis was the best predictor. In the short-term, food and temperature appeared to affect patch choice hierarchically; temperature was more important, although food can alter temperature preference during feeding periods. Over a 19-d experiment, mean temperatures occupied by fish offered low rations did decline as predicted by the behavioral energetics hypothesis, but the decline was less than 1.0 °C as opposed to a possible 5 °C decline. A short-term, bioenergetic response to food and temperature may be precluded by physiological costs of acclimation not considered explicitly in the behavioral energetics hypothesis.

  2. An experimental test of whether habitat corridors affect pollen transfer.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Townsend, Patricia A.; Levey, Douglas J.

    Abstract. Negative effects of habitat fragmentation are thought to be diminished when habitat patches are joined by a corridor. A key assumption is that corridors facilitate exchange rates of organisms between otherwise isolated patches. If the organisms are pollinators, corridors may be important for maintaining genetically viable populations of the plants that they pollinate. We tested the hypothesis that corridors increase the movement of insect pollinators into patches of habitat and thereby increase pollen transfer for two species of plants, one pollinated by butterflies (Lantana camara) and the other by bees and wasps (Rudbeckia hirta). We worked in an experimentalmore » landscape consisting of 40 greater than or equal to 1-ha patches of early-successional habitat in a matrix of forest. Within each of eight experimental units, two patches were connected by a corridor (150 X 25 m), and three were not. Patch shape varied to control for the area added by the presence of a corridor. Differences in patch shape also allowed us to test alternative hypotheses of how corridors might function. The Traditional Corridor Hypothesis posits that corridors increase immigration and emigration by functioning as movement conduits between patches. The Drift Fence Hypothesis posits that corridors function by ‘‘capturing’’ organisms dispersing through the matrix, redirecting them into associated habitat patches. Using fluorescent powder to track pollen, we found that pollen transfer by butterflies between patches connected by a corridor was significantly higher than between unconnected patches (all values mean plus or minus 1 SE: 59% plus or minus 9.2% vs. 25% plus or minus 5.2% of flowers receiving pollen). Likewise, pollen transfer by bees and wasps was significantly higher between connected patches than between unconnected patches (30% plus or minus 4.2% vs. 14.5% plus or minus 2.2%). These results support the Traditional Corridor Hypothesis. There was little support, however, for the Drift Fence Hypothesis. To generalize our results to a larger scale, we measured the probability of pollen transfer by butterflies as a function of distance along a 2000 X 75 m corridor. Pollen transfer probability exponentially declined with respect to distance and successfully predicted pollen transfer probability on the scale of our previous experiment. These results suggest that corridors facilitate pollen transfer in fragmented landscapes.« less

  3. Multi-Physics MRI-Based Two-Layer Fluid-Structure Interaction Anisotropic Models of Human Right and Left Ventricles with Different Patch Materials: Cardiac Function Assessment and Mechanical Stress Analysis

    PubMed Central

    Tang, Dalin; Yang, Chun; Geva, Tal; Gaudette, Glenn; del Nido, Pedro J.

    2011-01-01

    Multi-physics right and left ventricle (RV/LV) fluid-structure interaction (FSI) models were introduced to perform mechanical stress analysis and evaluate the effect of patch materials on RV function. The FSI models included three different patch materials (Dacron scaffold, treated pericardium, and contracting myocardium), two-layer construction, fiber orientation, and active anisotropic material properties. The models were constructed based on cardiac magnetic resonance (CMR) images acquired from a patient with severe RV dilatation and solved by ADINA. Our results indicate that the patch model with contracting myocardium leads to decreased stress level in the patch area, improved RV function and patch area contractility. PMID:21765559

  4. Actinic keratosis-related signs predictive of squamous cell carcinoma in renal transplant recipients: a nested case-control study.

    PubMed

    Jiyad, Z; O'Rourke, P; Soyer, H P; Green, A C

    2017-04-01

    Squamous cell carcinoma (SCC) and intraepidermal carcinoma (IEC) commonly arise in actinically damaged skin. To identify clinical features of actinic change that correlate with an increased risk of SCC or IEC in the short-to-medium term as guidance for prioritizing field treatment. In a nested case-control study, cases were renal transplant recipients who developed an incident SCC or IEC within 18 months following baseline examination and photography. Controls without SCC or IEC were matched to cases on age, sex and duration of immunosuppression. Predefined skin sites on the head, neck and upper limbs were examined using baseline photographs to assess objectively the following features of actinic damage: presence of actinic keratosis (AK) patch (defined as AK > 1 cm 2 ), number of AK patches, number of AKs and area affected by AK. Odds ratios (ORs) and 95% confidence intervals (CIs) were calculated using McNemar's test to identify differences in SCC/IEC risk combined and SCC risk alone between case and control skin sites. Thirty-nine cases were matched to 39 controls. Significant associations with the presence of an AK patch, number of AK patches, number of AKs and area affected by AKs were identified. The presence of an AK patch conferred an 18-fold increased risk of SCC (OR 18·00, 95% CI 2·84-750) and more than a sixfold increased risk of SCC/IEC combined (OR 6·60, 95% CI 2·56-21·66). AK patches are predictive of SCC/IEC development within 18 months. This can be used to guide site selection for field treatment in patients with widespread actinic damage. © 2016 British Association of Dermatologists.

  5. Contact Allergy to (Ingredients of) Toothpastes.

    PubMed

    de Groot, Anton

    The literature on contact allergy to (ingredients of) toothpastes is critically reviewed. We have found 47 case reports, small case series (n = 2-5) and citations published between 1900 and 2016 describing more than 60 patients allergic to toothpastes, and in addition 3 larger case series and many descriptions of toothpaste allergy among selected groups of patients. Allergic reactions usually manifest as cheilitis with or without dermatitis around the mouth, less frequently by oral symptoms. Formerly, many reactions were caused by cinnamon derivatives; more recently, reported allergens are diverse. A semiopen test or closed patch test with the toothpaste "as is" may be performed as an initial test, but a positive reaction should always be followed by confirmatory tests. The role of contact allergy to toothpastes in patients with oral symptoms (stomatitis, glossitis, gingivitis, buccal mucositis, burning, soreness, and possibly burning mouth syndrome and recurrent aphthous ulcers) is unclear and should be further investigated.

  6. Not so patchy story of attempted suicide…leading to 24 hours of deep sleep and survival!

    PubMed

    Trist, Adam Joseph; Sahota, Hardeep; Williams, Lucy

    2017-01-17

    Here, we present a somewhat unusual suicide attempt where, despite an unbelievable overdose with transdermal fentanyl patches, the patient survived. The patient-a woman aged 70 years, who has suffered from chronic back pain despite starting transdermal fentanyl patches in 2007. The unconventional method of attempted suicide was based on online research into deaths from fentanyl patch toxicity. She had gradually accumulated 100 µg fentanyl patches from repeat prescriptions, applying 14 patches with fatal intent, alongside 2 45 mg mirtazapine tablets, and concurrent therapeutic doses of tramadol and morphine sulfate oral solution. However, after 24 hours, she awoke from a deep sleep to the sound of the telephone ringing, somewhat amazed her drastic efforts had failed. During admission to Great Western hospital, she was seen by liaison psychiatry and subsequently transferred to the care of the pain management team, to which she had already been referred. 2017 BMJ Publishing Group Ltd.

  7. Caregivers' and physicians' attitudes to rotigotine transdermal patch versus oral Parkinson's disease medication: an observational study.

    PubMed

    Sieb, Jörn Peter; Themann, Peter; Warnecke, Tobias; Lauterbach, Thomas; Berkels, Reinhard; Grieger, Frank; Lorenzl, Stefan

    2015-05-01

    To provide real-world data on caregiver and physician perceptions of the advantages and disadvantages of rotigotine transdermal patch (Neupro * ) versus oral Parkinson's Disease (PD) medication. Cross-sectional, non-interventional study in routine clinical practice in Germany (NCT01330290). Patients had PD with documented need for care, and had received rotigotine transdermal patch as add-on to oral PD treatment for ≥1 month. Caregivers/nurses and physicians assessed rotigotine transdermal patch versus oral PD medications using questionnaires. Specific questions regarding the possible benefits of transdermal application were asked and comprised questions on: swallowing dysfunction, nausea/vomiting, monitoring therapy, once daily application, application independently from meals, application to sleeping patients, caregiving efforts (caregivers only) and clinical aspects (physicians only). Each question was assessed on a 5 point scale ranging from -2 (major disadvantage) to 2 (major advantage) compared with oral treatment. Primary outcomes were mean total scores of all questions for caregivers/nurses and physicians who provided responses for ≥4 questions. As there are no validated tools to assess physician/caregiver preference in the PD setting, there is no reference against which the current findings can be compared; this study serves to pilot the questionnaires. Questionnaire responses from 128 caregivers/nurses and 41 physicians were documented for 147 patients. One hundred (68%) patients had a caregiving family member; 40 (27%) were cared for by a nurse. Mean PD duration was 8.2 (SD 6.3) years; 136 (93%) patients were taking levodopa. Mean total score of caregivers'/nurses' questionnaires was 1.32 (SD 0.67) and of physicians' questionnaires was 1.46 (0.32) indicating a perceived advantage of rotigotine transdermal patch over oral PD therapy. Mean scores for individual questions were in the range 1.03-1.54 for caregivers/nurses and 1.15-1.87 for physicians. When given a choice about rationale to prescribe, physicians cited pharmaceutical form (patch) in 139 (95%) cases and active agent (rotigotine) in 89 (61%) cases. Caregivers/nurses and physicians perceived advantages with rotigotine transdermal patch compared to an oral PD medication as add-on therapy in patients with PD; advantages were observed in aspects of medical treatment as well as in everyday situations of caregiving of PD patients.

  8. Resource concentration hypothesis: effect of host plant patch size on density of herbivorous insects.

    PubMed

    Grez, A A; González, R H

    1995-09-01

    The resource concentration hypothesis (Root 1973) predicts that specialist herbivorous insects should be more abundant in large patches of host plants, because the insects are more likely to find and stay longer in those patches. Between August 1989 and January 1990 we experimentally tested Root's hypothesis by analyzing the numerical response of four species of herbivorous insects associated with patches of 4, 16, 64 and 225 cabbage plants, Brassica oleracea var. capitata. In addition, we studied the colonization of patches by adults of Plutella xylostella (L.) (Lepidoptera: Plutellidae), and the migration of their larvae in patches of different sizes. No herbivorous insect densities differed significantly with patch size. Adults of P. xylostella colonized all kind of patches equally. Larvae did not migrate between patches, and their disappearance rate did not differ between patches. The resource concentration hypothesis is organism-dependent, being a function of the adult and juvenile herbivore dispersal behavior in relation to the spatial scale of patchiness.

  9. Contact and photocontact allergy to oxybenzone.

    PubMed

    Lenique, P; Machet, L; Vaillant, L; Bensaïd, P; Muller, C; Khallouf, R; Lorette, G

    1992-03-01

    The purpose of this study was to determine the frequency of contact allergy and photocontact allergy to sunscreens. A consecutive series of 54 patients with suspected clinical photosensitivity were assessed. All had the same standardized photobiological investigation from January 1989 to December 1990, including patch tests and photopatch tests with 6 sunscreen agents. Oxybenzone was found to cause 4 cases of allergic contact dermatitis (with photoaggravation in 2), and 3 cases of photocontact dermatitis (13% of patients). This is probably due to the wide distribution of oxybenzone in sunscreens and other cosmetics, 2 patients with polymorphic light eruption and persistent light reactivity, respectively, were regular sunscreen users. Photobiological investigation is necessary to ensure accurate diagnosis, since sunscreen contact or photocontact allergy may simulate other photosensitivity eruptions.

  10. Smoking Cessation Treatment for Patients With Mental Disorders Using CBT and Combined Pharmacotherapy.

    PubMed

    Loreto, Aline Rodrigues; Carvalho, Carlos Felipe Cavalcanti; Frallonardo, Fernanda Piotto; Ismael, Flavia; Andrade, Arthur Guerra de; Castaldelli-Maia, João Maurício

    2017-01-01

    The aim of this study was to investigate smoking treatment effectiveness and retention in a population with and without mental disorders (MD). Participants received cognitive behavioral therapy (CBT) plus nicotine patch alone or in combination with other medications (i.e., gum, bupropion, or nortriptyline) for smoking cessation treatment in a Brazilian Psychosocial Care Center unit (CAPS), taking into account sociodemographics and smoking profile covariates. The study involved comparison of treatment success (seven-day point prevalence abstinence at the end of the treatment) and retention (presence of the individual in all of the four medical consultations and six group sessions) in two subsamples of patients with MD (n = 267) and without MD (n = 397) who were included in a six-week treatment provided by a CAPS from 2007 to 2013. The treatment protocol comprised group CBT and pharmacotherapy (nicotine patches, nicotine gums, and bupropion and nortriptyline available, prescribed by psychiatrists). Within patients with MD, CBT plus nicotine patch plus bupropion (aOR = 2.00, 95% CI [1.14, 3.50], p = .015) and CBT plus nicotine patch plus gum (aOR = 2.10, 95% CI [1.04, 4.23], p = .036) were associated with treatment success. Within patients without MD, female gender (aOR = 0.60, 95% CI [0.37, 0.95], p = .031) and lower Heaviness of Smoking Index score (aOR = 0.80, 95% CI [0.65, 0.99], p = .048) were associated with treatment success. No variable was associated with dropout or retention within patients with or without MD. Our findings support the use of CBT plus nicotine patch plus bupropion as well as CBT plus nicotine patch plus gum in samples with high rates of medical, psychiatric, and addiction disorders. These findings support those of previous studies in the general population. Pharmacological treatment associated with group CBT based on cognitive-behavioral concepts and combined with ongoing MD treatment seems to be the best option for smoking cessation treatment among patients with MD. Units that deal with patients with MD, such as CAPS in Brazil, should be encouraged to treat smoking addiction in this population. Future studies should investigate retention rates in other samples of patients with MD.

  11. Vestibular evoked myogenic potential according to middle ear condition in chronic otitis media with tympanic membrane perforation.

    PubMed

    Lee, Jun Seok; Lee, Sun Kyu; Shin, Il Ho; Yeo, Seung Geun; Park, Moon Suh; Byun, Jae Yong

    2014-01-01

    Vestibular evoked myogenic potential (VEMP) function results can vary between individuals with different middle ear conditions. Therefore, by analyzing VEMP results after paper patching, we can predict the condition of the middle ear in chronic otitis media (COM) patients. VEMP responses decrease with impairment of sound transmission, such as in conductive hearing loss (CHL). COM with tympanic membrane (TM) perforation is a common disorder that causes various degrees of CHL. The aim of this study was to evaluate and clarify the VEMP responses in patients with COM with different middle ear pathology. This study included 50 patients with unilateral COM with TM perforation. Initial pure-tone audiometry (PTA) and VEMP responses were recorded. After paper patching, PTA and VEMP were re-performed. Each VEMP response was compared with those of the healthy controls. Moreover, VEMP responses between pre- and post-paper patching were compared. There was a positive correlation between normalizing of VEMP parameters, such as p13 and VEMP asymmetry ratio (VAR), and reduction of air-bone gap in patients with COM after paper patching. The VEMP response in patients with COM with intact ossicle and clean mucosa was more normalized compared with those in patients with COM with different middle ear conditions.

  12. Cost-effectiveness analysis of a new 8% capsaicin patch compared to existing therapies for postherpetic neuralgia.

    PubMed

    Armstrong, Edward P; Malone, Daniel C; McCarberg, Bill; Panarites, Christopher J; Pham, Sissi V

    2011-05-01

    The purpose of this study was to compare the cost effectiveness of a new 8% capsaicin patch, compared to the current treatments for postherpetic neuralgia (PHN), including tricyclic antidepressants (TCAs), topical lidocaine patches, duloxetine, gabapentin, and pregabalin. A 1-year Markov model was constructed for PHN with monthly cycles, including dose titration and management of adverse events. The perspective of the analysis was from a payer perspective, managed-care organization. Clinical trials were used to determine the proportion of patients achieving at least a 30% improvement in PHN pain, the efficacy parameter. The outcome was cost per quality-adjusted life-year (QALY); second-order probabilistic sensitivity analyses were conducted. The effectiveness results indicated that 8% capsaicin patch and topical lidocaine patch were significantly more effective than the oral PHN products. TCAs were least costly and significantly less costly than duloxetine, pregabalin, topical lidocaine patch, 8% capsaicin patch, but not gabapentin. The incremental cost-effectiveness ratio for the 8% capsaicin patch overlapped with the topical lidocaine patch and was within the accepted threshold of cost per QALY gained compared to TCAs, duloxetine, gabapentin, and pregablin. The frequency of the 8% capsaicin patch retreatment assumption significantly impacts its cost-effectiveness results. There are several limitations to this analysis. Since no head-to-head studies were identified, this model used inputs from multiple clinical trials. Also, a last observation carried forward process was assumed to have continued for the duration of the model. Additionally, the trials with duloxetine may have over-predicted its efficacy in PHN. Although a 30% improvement in pain is often an endpoint in clinical trials, some patients may require greater or less improvement in pain to be considered a clinical success. The effectiveness results demonstrated that 8% capsaicin and topical lidocaine patches had significantly higher effectiveness rates than the oral agents used to treat PHN. In addition, this cost-effectiveness analysis found that the 8% capsaicin patch was similar to topical lidocaine patch and within an accepted cost per QALY gained threshold compared to the oral products.

  13. Chemical analysis of 2,4-toluene diisocyanate, 1,6-hexamethylene diisocyanate and isophorone diisocyanate in petrolatum patch-test preparations.

    PubMed

    Frick-Engfeldt, Malin; Zimerson, Erik; Karlsson, Daniel; Marand, Asa; Skarping, Gunnar; Isaksson, Marléne; Bruze, Magnus

    2005-09-01

    Isocyanates with the general formula R-(N=C=O) are theoretically contact sensitizers. However, allergic contact dermatitis (ACD) from isocyanates is seldom reported. In previous reports, patients reacted to their isocyanate-based work materials but not to commercial patch-test preparations of isocyanates. Therefore, we suspected that the low frequency of reported ACD from isocyanates was partly due to inadequate commercial preparations. A past study also showed the concentrations of diphenylmethane-4,4'-diisocyanate (4,4'-MDI) in petrolatum preparations to be much lower than declared. In this study, 2,4-toluene diisocyanate (2,4-TDI), 1,6-hexamethylene diisocyanate (1,6-HDI), and isophorone diisocyanate (IPDI) were investigated in a similar fashion. In preparations from 12 dermatology departments and two suppliers of patch-test allergens, we determined the isocyanate content as the isocyanate-dibutylamine derivative, using liquid chromatography and mass spectrometry. The preparations were considered stable if the ratio between the stated and found concentrations was within the range of 0.8 to 1.2. Although 28 of 36 investigated preparations had ratios outside of the stable range, they were in its vicinity, which indicates that preparations of 2,4-TDI, 1,6-HDI, and IPDI are more stable than are preparations of 4,4'-MDI where previously reported results showed ratios far outside of stable range. As opposed to preparations of 4,4'-MDI, preparations of 2,4-TDI, 1,6-HDI, and IPDI can be considered to be stable.

  14. Constituents of smoke from cigarettes made from diverted nicotine replacement therapy patches.

    PubMed

    Morrissey, Hana; Ball, Patrick; Boland, Martin; Hefler, Marita; Thomas, David P

    2016-03-01

    Anecdotes of nicotine replacement therapy patch misuse associated with the introduction of smoke-free prisons have been reported by media internationally, including Canada in 2006, New Zealand in 2011 and Australia in 2014. This study identifies chemical compounds released through diverted nicotine replacement therapy patches when they are smoked. Two samples were produced: (i) shredded 21 mg nicotine replacement therapy patches rolled with tea leaves into a cigarette; and (ii) patches boiled in water and tea leaves, and then dried tea leaves rolled into a cigarette. The smoke was tested for nicotine, caffeine and toxins. High-performance liquid chromatography, mass spectrometry and spectrophotometry were used to detect the presence and quantity of nicotine and caffeine. A specialised laboratory was contracted to test the presence of toxins. Nicotine was liberated when the two samples were burnt but not if the nicotine replacement therapy patches were boiled in water alone. High concentrations of formaldehyde, acetaldehyde, acrolein, toluene, xylene and heavy metals were also released. Nicotine is released when diverted nicotine replacement therapy patches are smoked, as are caffeine and harmful toxins. These toxins have the potential to cause short- and long-term health damage. © 2015 Australasian Professional Society on Alcohol and other Drugs.

  15. "Phase capture" in amblyopia: the influence function for sampled shape.

    PubMed

    Levi, Dennis M; Li, Roger W; Klein, Stanley A

    2005-06-01

    This study was concerned with what stimulus information humans with amblyopia use to judge the shape of simple objects. We used a string of four Gabor patches to define a contour. A fifth, center patch served as the test pattern. The observers' task was to judge the location of the test pattern relative to the contour. The contour was either a straight line, or an arc with positive or negative curvature. We asked whether phase shifts in the inner or outer pairs of patches distributed along the contour influence the perceived shape. That is, we measured the phase shift influence function. Our results, consistent with previous studies, show that amblyopes are imprecise in shape discrimination, showing elevated thresholds for both lines and curves. We found that amblyopes often make much larger perceptual errors (biases) than do normal observers in the absence of phase shifts. These errors tend to be largest for curved shapes and at large separations. In normal observers, shifting the phase of inner patches of the string by 0.25 cycle results in almost complete phase capture (attraction) at the smallest separation (2 lambda), and the capture effect falls off rapidly with separation. A 0.25 cycle shift of the outer pair of patches has a much smaller effect, in the opposite direction (repulsion). While several amblyopic observers showed reduced capture by the phase of the inner patches, to our surprise, several of the amblyopes were sensitive to the phase of the outer patches. We used linear multiple regression to determine the weights of all cues to the task: the carrier phase of the inner patches, carrier phase of the outer patches and the envelope of the outer patches. Compared to normal observers, some amblyopes show a weaker influence of the phase of the inner patches, and a stronger influence of both the phase and envelope of the outer patches. We speculate that this may be a consequence of abnormal "crowding" of the inner patches by the outer ones.

  16. Endoscopic observation of different repair patterns in human traumatic tympanic membrane perforations.

    PubMed

    Huang, Peng; Zhang, Shujun; Gong, Xinhong; Wang, Xuesong; Lou, Zi-Han

    2017-08-03

    In the last decade, there has been an increasing use of biomaterial patches in the regeneration of traumatic tympanic membrane perforations. The major advantages of biomaterial patches are to provisionally restore the physiological function of the middle ear, thereby immediately improving ear symptoms, and act as a scaffold for epithelium migration. However, whether there are additional biological effects on eardrum regeneration is unclear for biological material patching in the clinic. This study evaluated the healing response for different repair patterns in human traumatic tympanic membrane perforations by endoscopic observation. In total, 114 patients with traumatic tympanic membrane perforations were allocated sequentially to two groups: the spontaneous healing group (n=57) and Gelfoam patch-treated group (n=57). The closure rate, closure time, and rate of otorrhea were compared between the groups at 3 months. Ultimately, 107 patients were analyzed in the two groups (52 patients in the spontaneous healing group vs. 55 patients in the Gelfoam patch-treated group). The overall closure rate at the end of the 3 month follow-up period was 90.4% in the spontaneous healing group and 94.5% in the Gelfoam patch-treated group; the difference was not statistically significant (p>0.05). However, the total average closure time was significantly different between the two groups (26.8±9.1 days in the spontaneous healing group vs. 14.7±9.1 days in the Gelfoam patch-treated group, p<0.01). In addition, the closure rate was not significantly different between the spontaneous healing group and Gelfoam patch-treated group regardless of the perforation size. The closure time in the Gelfoam patch-treated group was significantly shorter than that in the spontaneous healing group regardless of the perforation size (small perforations: 7.1±1.6 days vs. 12.6±3.9, medium-sized perforations: 13.3±2.2 days vs. 21.8±4.2 days, and large perforations: 21.2±4.7 days vs. 38.4±5.7 days; p<0.01). In the regeneration of traumatic tympanic membrane perforations, Gelfoam patching not only plays a scaffolding role for epithelial migration, it also promotes edema and hyperplasia of granulation tissue at the edges of the perforation and accelerates eardrum healing. Copyright © 2017 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  17. Povidone-iodine induced post-surgical irritant contact dermatitis localized outside of the surgical incision area. Report of 27 cases and a literature review.

    PubMed

    Borrego, Leopoldo; Hernández, Noelia; Hernández, Zaida; Peñate, Yeray

    2016-05-01

    Povidone-iodine solution is an antiseptic that is used worldwide as surgical paint and is considered to have a low irritant potential. Post-surgical severe irritant dermatitis has been described after the misuse of this antiseptic in the surgical setting. Between January 2011 and June 2013, 27 consecutive patients with post-surgical contact dermatitis localized outside of the surgical incision area were evaluated. Thirteen patients were also available for patch testing. All patients developed dermatitis the day after the surgical procedure. Povidone-iodine solution was the only liquid in contact with the skin of our patients. Most typical lesions were distributed in a double lumbar parallel pattern, but they were also found in a random pattern or in areas where a protective pad or an occlusive medical device was glued to the skin. The patch test results with povidone-iodine were negative. Povidone-iodine-induced post-surgical dermatitis may be a severe complication after prolonged surgical procedures. As stated in the literature and based on the observation that povidone-iodine-induced contact irritant dermatitis occurred in areas of pooling or occlusion, we speculate that povidone-iodine together with occlusion were the causes of the dermatitis epidemic that occurred in our surgical setting. Povidone-iodine dermatitis is a problem that is easily preventable through the implementation of minimal routine changes to adequately dry the solution in contact with the skin. © 2015 The International Society of Dermatology.

  18. The Efficacy and Tolerability of the Clonidine Transdermal Patch in the Treatment for Children with Tic Disorders: A Prospective, Open, Single-Group, Self-Controlled Study.

    PubMed

    Song, Pan-Pan; Jiang, Li; Li, Xiu-Juan; Hong, Si-Qi; Li, Shuang-Zi; Hu, Yue

    2017-01-01

    To evaluate the efficacy and tolerability of a clonidine transdermal patch in the treatment of children with tic disorders (TD) and to establish a predictive model for patients. Forty-one patients who met the inclusion criteria entered into 12 weeks of prospective, open, single-group, self-controlled treatment with a clonidine transdermal patch. The Yale Global Tic Severity Scale (YGTSS) was employed before therapy (baseline) and at 4, 8, and 12 weeks after therapy. (1) The total effect rates of treatment with a clonidine transdermal patch were 29.27, 53.66, and 63.41% at 4, 8, and 12 weeks, respectively. Compared with the baseline, the differences were significant at three different observation periods. (2) Compared to the level of 25% reduction, there were significant decreases in the score-reducing rate of motor tic and total tic severities at 12 weeks. (3) If the disease course was ≤24 months and the motor tic score was <16 at the baseline, there was an effective rate of 100% for treatment with the clonidine transdermal patch. If the disease course was ≤24 months and the motor tic score was >16, there was an effective rate of 57.1%. If the disease course was >24 months and the clinical classification was chronic TD, there was an effective rate of 62.5%. If the disease course was >24 months and the clinical classification was Tourette's syndrome, 90% of the patients were invalid. (4) The main adverse events were rash, slight dizziness, and headache. (1) When patients were pretreated with a D2-dopamine receptor antagonist that was ineffective or not tolerated well, switching to a clonidine transdermal patch treatment was effective and safe. (2) A clonidine transdermal patch could be a first-line medication for mild and moderate TD cases that are characterized by motor tics.

  19. UV-cured adhesives for carbon fiber composite applications

    NASA Astrophysics Data System (ADS)

    Lu, Hsiao-Chun

    Carbon fiber composite materials are increasingly used in automobile, marine, and aerospace industries due to their unique properties, including high strength, high stiffness and low weight. However, due to their brittle characteristic, these structures are prone to physical damage, such as a bird strike or impact damage. Once the structure is damaged, it is important to have fast and reliable temporary repair until the permanent repair or replacement can take place. In this dissertation, UV-based adhesives were used to provide a bonding strength for temporary repair. Adhesively bonded patch repair is an efficient and effective method for temporary repair. In this study, precured patches (hard patches) and dry fabric patches with laminating resins (soft patches) were performed. UV-based epoxy adhesives were applied to both patch repair systems. For precured patch repair, the bonding strengths were investigated under different surface treatments for bonding area and different adhesives thicknesses. The shear stresses of different UV exposure times and curing times were tested. Besides, the large patch repair was investigated as well. For soft patch repair, the hand wet lay-up was applied due to high viscosity of UV resins. A modified single lap shear testing (ASTM D5868) was applied to determine the shear stress. The large patches used fiber glass instead of carbon fiber to prove the possibility of repair with UV epoxy resin by hand wet lay-up process. The hand lay-up procedure was applied and assisted by vacuum pressure to eliminate the air bubbles and consolidate the patches. To enhance the bonding strength and effective soft patch repair, vacuum assisted resin transferring molding (VaRTM) is the better option. However, only low viscosity resins can be operated by VaRTM. Hence, new UV-based adhesives were formulated. The new UV-based adhesives included photoinitiator (PI), epoxy and different solvents. Solvents were used to compound the photoinitiator into epoxy monomer. Acetone, tetrahydrofuran (THF) and chloroform were used as well as their anhydrous solvents. The UV exposure times and curing times of new UV-based resins were tested. FT-IR, DSC and DMA were used to investigate structure, glass transition temperatures(Tg) and properties of polymer. In summary, the UV-based adhesive was applied to adhesively bonded hard patch and soft patch repair. In addition, new UV-based resins were formulated for the VaRTM process. The in-field repair can be effective and efficient by using UV adhesives.

  20. Ex-vivoand in-vitro assessment of mucoadhesive patches containing the gel-forming polysaccharide psyllium for buccal delivery of chlorhexidine base.

    PubMed

    Cavallari, Cristina; Brigidi, Patrizia; Fini, Adamo

    2015-12-30

    The aim of the present study was to evaluate the gel-forming polysaccharide psyllium in the preparation of mucoadhesive patches for the controlled release of chlorhexidine (CHX) to treat pathologies in the oral cavity, using the casting-solvent evaporation technique. A number of different film-forming semi-synthetic polymers, such as sodium carboxymethyl cellulose (SCMC) and hydroxypropylmethyl cellulose (HPMC) were evaluated for comparison. The patch formulations were characterized in terms of drug content, morphology surface, swelling and mucoadhesive properties, microbiology inhibition assay and in vitro release tests. Three ex-vivo testswere carried out using porcine mucosa: an alternative dissolution test using artificial saliva that allows contemporary measurement of dissolution and mucoadhesion, a permeation test through the mucosa and the measurement of mucoadhesion using a Nouy tensile tester, as the maximum force required for the separation of the patch from the mucosa surface. The patches were also examined for determination of the minimum inhibitory concentration in cultures of Escherichia coli and Staphylococcus aureus. All the patches incorporating psyllium were found suitable in terms of external morphology, mucoadhesion and controlled release of the drug: in the presence of psyllium the drug displays prolonged zero-order release related to slower swelling rate of the system. Copyright © 2015. Published by Elsevier B.V.

Top