Sample records for pc boiler study

  1. Characterization of fly ashes from circulating fluidized bed combustion (CFBC) boilers cofiring coal and petroleum coke

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feihu Li; Jianping Zhai; Xiaoru Fu

    2006-08-15

    The chemistry, mineralogy, morphology, and particle size distribution were investigated in fly ashes from the burning of Datong (ShanXi, China) bituminous coal and the cofiring of Mideast high-sulfur petroleum coke (PC) with 30:70 (cal %) and 50:50 (cal %) blends of Datong bituminous coal in two commercial CFBC boilers. With the exception of CaO, the amounts of major oxides in the fly ashes from cofiring PC and coal were close to those of the common coal fly ashes. The PC-coal fly ashes were enriched in Ni, V, and Mo, implying these trace elements were mainly derived from PC. Ni andmore » V, along with several other elements, such as Cr, Cu, Se, Pb, U, Th, and possibly As and Cd, increased in content with a decrease in temperature of the electrostatic precipitator (ESP). The results of chemistry, mineralogy, and morphology studies suggested that the desulfurization rate of the CFBC boilers at current conditions was low, and the PC tends to coarsen the fly ash particles and increase the loss on ignition (LOI) values, making these fly ashes unsuitable for use as a cement additive or a mineral admixture in concrete. Further studies on the combustion status of the CFBC boilers are needed if we want to be able to increase the desulfurization rate and produce high-quality fly ashes for broader and full utilization. 22 refs., 4 figs., 4 tabs.« less

  2. Comparion of Mercury Emissions Between Circulating Fluidized Bed Boiler and Pulverized Coal Boiler

    NASA Astrophysics Data System (ADS)

    Wang, Y. J.; Duan, Y. F.; Zhao, C. S.

    Mercury emissions between a circulating fluidized bed (CFB) utility boiler and two pulverized coal (PC) boilers equipped with electrostatic precipitators (ESP) were in situ measured and compared. The standard Ontario Hydro Method (OHM) was used to sample the flue gas before and after the ESP. Various mercury speciations such as Hg0, Hg2+ and Hgp in flue gas and total mercury in fly ashes were analyzed. The results showed that the mercury removal rate of the CFB boiler is nearly 100%; the mercury emission in stack is only 0.028 g/h. However, the mercury removal rates of the two PC boilers are 27.56% and 33.59% respectively, the mercury emissions in stack are 0.80 and 51.78 g/h respectively. It concluded that components of the ESP fly ashes especially their unburnt carbons have remarkable influence on mercury capture. Pore configurations of fine fly ash particles have non-ignored impacts on mercury emissions.

  3. Simulation on an optimal combustion control strategy for 3-D temperature distributions in tangentially pc-fired utility boiler furnaces.

    PubMed

    Wang, Xi-fen; Zhou, Huai-chun

    2005-01-01

    The control of 3-D temperature distribution in a utility boiler furnace is essential for the safe, economic and clean operation of pc-fired furnace with multi-burner system. The development of the visualization of 3-D temperature distributions in pc-fired furnaces makes it possible for a new combustion control strategy directly with the furnace temperature as its goal to improve the control quality for the combustion processes. Studied in this paper is such a new strategy that the whole furnace is divided into several parts in the vertical direction, and the average temperature and its bias from the center in every cross section can be extracted from the visualization results of the 3-D temperature distributions. In the simulation stage, a computational fluid dynamics (CFD) code served to calculate the 3-D temperature distributions in a furnace, then a linear model was set up to relate the features of the temperature distributions with the input of the combustion processes, such as the flow rates of fuel and air fed into the furnaces through all the burners. The adaptive genetic algorithm was adopted to find the optimal combination of the whole input parameters which ensure to form an optimal 3-D temperature field in the furnace desired for the operation of boiler. Simulation results showed that the strategy could soon find the factors making the temperature distribution apart from the optimal state and give correct adjusting suggestions.

  4. The IBM PC as an Online Search Machine. Part 6: Uploading.

    ERIC Educational Resources Information Center

    Kolner, Stuart J.

    1986-01-01

    This discussion of uploading (the transmission of information from local memory to a remote system) covers benefits, disadvantages, host system features, technical aspects, and four examples of uploading using CROSSTALK. Examples include function keys, searcher assistance with commonly-used terms, the use of hedges and boiler-plate searching, and…

  5. FETC/EPRI Biomass Cofiring Cooperative Agreement. Quaterly technical report, January 1-March 30m 1997

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hughes, E.; Tillman, D.

    1997-12-01

    Cofiring is considered to be the most promising near-term approach to fossil C0{sub 2} emissions mitigation through biomass usage. Consequently FETC and EPRI have entered into a cooperative agreement: `Cofiring Biomass and Waste-Derived fuels in Electric Utility Coal- Fired Boilers.` This agreement supports sixteen (16) EPRI research projects, each contributing to the commercialization of systems to address greenhouse gas emissions. These projects include: (1) cofiring combustion testing at the Seward Generating Station of GPU Genco; (2) fuel preparation testing at the Greenidge Generating Station of NYSEG; (3) precommercial testing of cofiring at the Allen and Colbert Fossil Plants of TVA;more » (4) testing of switchgrass cofiring at the Blount St. Station of Madison Gas & Electric; (5) high percentage biomass cofiring with Southern Company; (6) urban wood waste cofiring at the supercritical cyclone boiler at Michigan City Generating Station of Northern Indiana Public Service Co. (NIPSCO); (7) evaluation of switchgrass cofiring with Nebraska Public Power District at Sandia National Laboratories in Livermore, CA; (8) waste plastics cofiring with Duke Power in a tangentially-fired pulverized coal (PC) boiler; (9) cofiring a mixture of plastics, fiber, and pulp industry wastes with South Carolina Electric and Gas; (10) urban wood waste cofiring evaluation and testing by the University of Pittsburgh in stoker boilers; (11) assessment of toxic emissions from cofiring of wood and coal; (12) development of fuel and power plant models for analysis and interpretation of cofiring results; (13) analysis of C0{sub 2} utilization in algal systems for wastewater treatment; (14) combustion testing and combustor development focusing on high percentage cofiring; (15) analysis of problems and potential solutions to the sale of flyash from coal-fired boilers practicing cofiring; and (16) analysis of C0{sub 2} capture and disposal systems. During the second quarter of this contract, from January 1, 1997 through March 31, 1997, significant progress has been made on these projects. This progress focuses upon analysis of data from the cofiring tests, construction of systems to promote additional cofiring tests, and initiation of tasks evaluating alternatives to cofiring. This report contains a brief description of the progress made during the second quarter of the contract, focusing upon test results from the Seward Generating Station, where parametric testing at a wall-fired PC boiler was used to evaluate cofiring using separate feeding of wood and coal to the energy generation system.« less

  6. Characteristics of fly ashes from full-scale coal-fired power plants and their relationship to mercury adsorption

    USGS Publications Warehouse

    Lu, Y.; Rostam-Abadi, M.; Chang, R.; Richardson, C.; Paradis, J.

    2007-01-01

    Nine fly ash samples were collected from the particulate collection devices (baghouse or electrostatic precipitator) of four full-scale pulverized coal (PC) utility boilers burning eastern bituminous coals (EB-PC ashes) and three cyclone utility boilers burning either Powder River Basin (PRB) coals or PRB blends,(PRB-CYC ashes). As-received fly ash samples were mechanically sieved to obtain six size fractions. Unburned carbon (UBC) content, mercury content, and Brunauer-Emmett-Teller (BET)-N2 surface areas of as-received fly ashes and their size fractions were measured. In addition, UBC particles were examined by scanning electron microscopy, high-resolution transmission microscopy, and thermogravimetry to obtain information on their surface morphology, structure, and oxidation reactivity. It was found that the UBC particles contained amorphous carbon, ribbon-shaped graphitic carbon, and highly ordered graphite structures. The mercury contents of the UBCs (Hg/UBC, in ppm) in raw ash samples were comparable to those of the UBC-enriched samples, indicating that mercury was mainly adsorbed on the UBC in fly ash. The UBC content decreased with a decreasing particle size range for all nine ashes. There was no correlation between the mercury and UBC contents of different size fractions of as-received ashes. The mercury content of the UBCs in each size fraction, however, generally increased with a decreasing particle size for the nine ashes. The mercury contents and surface areas of the UBCs in the PRB-CYC ashes were about 8 and 3 times higher than UBCs in the EB-PC ashes, respectively. It appeared that both the particle size and surface area of UBC could contribute to mercury capture. The particle size of the UBC in PRB-CYC ash and thus the external mass transfer was found to be the major factor impacting the mercury adsorption. Both the particle size and surface reactivity of the UBC in EB-PC ash, which generally had a lower carbon oxidation reactivity than the PRB-PC ashes, appeared to be important for the mercury adsorption. ?? 2007 American Chemical Society.

  7. NOx Control for Utility Boiler OTR Compliance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hamid Farzan

    Under sponsorship of the Department of Energy's National Energy Technology Laboratory (NETL), the Babcock and Wilcox Company (B and W), and Fuel Tech teamed together to investigate an integrated solution for NO{sub x} control. The system is comprised of B and W's DRB-4Z{trademark} ultra low-NO{sub x} pulverized coal (PC) burner technology and Fuel Tech's NOxOUT{reg_sign}, a urea-based selective non-catalytic reduction (SNCR) technology. Development of the low-NO{sub x} burner technology has been a focus in B and W's combustion program. The DRB-4Z{trademark} burner is B and W's newest low-NO{sub x} burner capable of achieving very low NO{sub x}. The burner ismore » designed to reduce NO{sub x} by controlled mixing of the fuel and air. Based on data from several 500 to 600 MWe boilers firing PRB coal, NOx emissions levels of 0.15 to 0.20 lb/ 106 Btu have been achieved from the DRB-4Z{trademark} burners in combination with overfire air ports. Although NOx emissions from the DRB-4Z{trademark} burner are nearing the Ozone Transport Rule (OTR) level of 0.15 lb NO{sub x}/106 Btu, the utility boiler owners can still benefit from the addition of an SNCR and/or SCR system in order to comply with the stringent NO{sub x} emission levels facing them. Large-scale testing is planned in B and W's 100-million Btu/hr Clean Environment Development Facility (CEDF) that simulates the conditions of large coal-fired utility boilers. The objective of the project is to achieve a NO{sub x} level below 0.15 lb/106 Btu (with ammonia slip of less than 5 ppm) in the CEDF using PRB coal and B and W's DRB-4Z{trademark} low-NO{sub x} pulverized coal (PC) burner in combination with dual zone overfire air ports and Fuel Tech's NO{sub x}OUT{reg_sign}. During this period B and W prepared and submitted the project management plan and hazardous substance plan to DOE. The negotiation of a subcontract for Fuel Tech has been started.« less

  8. Mercury Emission Measurement in Coal-Fired Boilers by Continuous Mercury Monitor and Ontario Hydro Method

    NASA Astrophysics Data System (ADS)

    Zhu, Yanqun; Zhou, Jinsong; He, Sheng; Cai, Xiaoshu; Hu, Changxin; Zheng, Jianming; Zhang, Le; Luo, Zhongyang; Cen, Kefa

    2007-06-01

    The mercury emission control approach attaches more importance. The accurate measurement of mercury speciation is a first step. Because OH method (accepted method) can't provide the real-time data and 2-week time for results attained, it's high time to seek on line mercury continuous emission monitors(Hg-CEM). Firstly, the gaseous elemental and oxidized mercury were conducted to measure using OH and CEM method under normal operation conditions of PC boiler after ESP, the results between two methods show good consistency. Secondly, through ESP, gaseous oxidized mercury decrease a little and particulate mercury reduce a little bit, but the elemental mercury is just the opposite. Besides, the WFGD system achieved to gaseous oxidized mercury removal of 53.4%, gaseous overall mercury and elemental mercury are 37.1% and 22.1%, respectively.

  9. Capacity mapping for optimum utilization of pulverizers for coal fired boilers - article no. 032201

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bhattacharya, C.

    2008-09-15

    Capacity mapping is a process of comparison of standard inputs with actual fired inputs to assess the available standard output capacity of a pulverizer. The base capacity is a function of grindability; fineness requirement may vary depending on the volatile matter (VM) content of the coal and the input coal size. The quantity and the inlet will change depending on the quality of raw coal and output requirement. It should be sufficient to dry pulverized coal (PC). Drying capacity is also limited by utmost PA fan power to supply air. The PA temperature is limited by air preheater (APH) inletmore » flue gas temperature; an increase in this will result in efficiency loss of the boiler. The higher PA inlet temperature can be attained through the economizer gas bypass, the steam coiled APH, and the partial flue gas recirculation. The PS/coal ratioincreases with a decrease in grindability or pulverizer output and decreases with a decrease in VM. The flammability of mixture has to be monitored on explosion limit. Through calibration, the PA flow and efficiency of conveyance can be verified. The velocities of coal/air mixture to prevent fallout or to avoid erosion in the coal carrier pipe are dependent on the PC particle size distribution. Metal loss of grinding elements inversely depends on the YGP index of coal. Variations of dynamic loading and wearing of grinding elements affect the available milling capacity and percentage rejects. Therefore, capacity mapping in necessary to ensure the available pulverizer capacity to avoid overcapacity or undercapacity running of the pulverizing system, optimizing auxiliary power consumption. This will provide a guideline on the distribution of raw coal feeding in different pulverizers of a boiler to maximize system efficiency and control, resulting in a more cost effective heat rate.« less

  10. Cost and performance of coal-based energy in Brazil

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Temchin, J.; DeLallo, M.R.

    1998-07-01

    As part of the US Department of Energy's (DOE) efforts to establish the strategic benefits of Clean Coal Technologies (CCT), there is a need to evaluate the specific market potential where coal is a viable option. One such market is Brazil, where significant growth in economic development requires innovative and reliable technologies to support the use of domestic coal. While coal is Brazil's most abundant and economic fossil energy resource, it is presently under utilized in the production of electrical power. This report presents conceptual design for pulverized coal (PC) and circulating fluidized-bed combustion (CFBC) options with resulting capital, operatingmore » and financial parameters based on Brazil application conditions. Recent PC and CFBC plant capital costs have dropped with competition in the generation market and have established a competitive position in power generation. Key issues addressed in this study include: Application of market based design approach for FBC and PC, which is competitive within the current domestic, and international power generation markets. Design, fabrication, purchase, and construction methods which reduce capital investment while maintaining equipment quality and plant availability. Impact on coast and performance from application of Brazilian coals, foreign trade and tax policies, construction logistics, and labor requirements. Nominal production values of 200 MWe and 400 MWe were selected for the CFBC power plant and 400 MWe for the PC. The 400 MWe size was chosen to be consistent with the two largest Brazilian PC units. Fluidized bed technology, with limited experience in single units over 200 MW, would consist of two 200 MWe circulating fluidized bed boilers supplying steam to one steam turbine for the 400 MWe capacity. A 200 MWe capacity unit was also developed for CFBC option to support opportunities in re-powering and where specific site or other infrastructure constraints limit production.« less

  11. Mercury Emission Measurement at a CFB Plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    John Pavlish; Jeffrey Thompson; Lucinda Hamre

    2009-02-28

    In response to pending regulation to control mercury emissions in the United States and Canada, several projects have been conducted to perform accurate mass balances at pulverized coal (pc)-fired utilities. Part of the mercury mass balance always includes total gaseous mercury as well as a determination of the speciation of the mercury emissions and a concentration bound to the particulate matter. This information then becomes useful in applying mercury control strategies, since the elemental mercury has traditionally been difficult to control by most technologies. In this instance, oxidation technologies have proven most beneficial for increased capture. Despite many years ofmore » mercury measurement and control projects at pc-fired units, far less work has been done on circulating fluidized-bed (CFB) units, which are able to combust a variety of feedstocks, including cofiring coal with biomass. Indeed, these units have proven to be more problematic because it is very difficult to obtain a reliable mercury mass balance. These units tend to have very different temperature profiles than pc-fired utility boilers. The flexibility of CFB units also tends to be an issue when a mercury balance is determined, since the mercury inputs to the system come from the bed material and a variety of fuels, which can have quite variable chemistry, especially for mercury. In addition, as an integral part of the CFB operation, the system employs a feedback loop to circulate the bed material through the combustor and the solids collection system (the primary cyclone), thereby subjecting particulate-bound metals to higher temperatures again. Despite these issues, CFB boilers generally emit very little mercury and show good native capture. The Energy & Environmental Research Center is carrying out this project for Metso Power in order to characterize the fate of mercury across the unit at Rosebud Plant, an industrial user of CFB technology from Metso. Appropriate solids were collected, and flue gas samples were obtained using the Ontario Hydro method, mercury continuous emission monitors, and sorbent trap methods. In addition, chlorine and fluorine were determined for solids and in the flue gas stream. Results of this project have indicated a very good mercury mass balance for Rosebud Plant, indicating 105 {+-} 19%, which is well within acceptable limits. The mercury flow through the system was shown to be primarily in with the coal and out with the flue gas, which falls outside of the norm for CFB boilers.« less

  12. Study on the electrochemical corrosion behavior of industrial boilers

    NASA Astrophysics Data System (ADS)

    Wu, Xiaoyang; Huang, Song; Zhang, Wenpin; Feng, Qiang; Huang, Yong

    2018-06-01

    In this paper, industrial boilers are used as the research object, and Boilerentiodynamic polarization analysis of boiler steel is used to study the electrochemical corrosion behavior in the boiler water. The electrochemical corrosion nature and morphology of the samples were tested through experiments. The study shows: the corrosion resistance of the samples will decrease significantly with the increase of the operating time of boilers. Dissolved solids and Cl- in the boiler water will destroy the original protective film, of which the increase of its content is the main reason for the deterioration of the material properties.

  13. An investigation on polycyclic aromatic hydrocarbon emissions from pulverized coal combustion systems

    PubMed

    Pisupati; Wasco; Scaroni

    2000-05-29

    Results from a series of tests conducted to study the emission of polynuclear or polycyclic aromatic hydrocarbons (PAHs) from bench-scale and small industrial, water-tube boiler are discussed. A Middle Kittanning, and Upper Freeport seam coals were used in the study. Samples were extracted from the reactor outlet and from the inlet and outlet sides of the research boiler's (RB) baghouse using EPA promulgated methods.Only acenaphthene and fluoranthene were detected in down-fired combustor (DFC) samples. In addition to these two, naphthalene was detected in the RB samples. Emission factors ranged from 80 to 320 &mgr;g/kg of fuel fired. Although there were minor trends in the emissions' data, given the reproducibility limits for PAH compounds, no significant differences were found in the emissions with respect to the fuel type or form (pulverized coal (PC) vs. coal-water slurry fuel (CWSF), and raw vs. cleaned coal) and firing conditions (high and low excess air). The PAH emissions showed a decrease with increase in the firing rate.A bench-scale drop-tube reactor (DTR) was used to study the effects of temperature and residence time on PAH formation. The results revealed near constant PAH concentrations in the solid-phase samples, while the PAH concentrations in the vapor-phase samples increased as a function of temperature. At a temperature of around 1300 degrees C, the rate of PAH formation was exceeded by the rate of PAH oxidation, and PAH concentrations in the vapor phase began to decrease.

  14. BOILER DESIGN CRITERIA FOR DRY SORBENT SO2 CONTROL WITH LOW-NOX BURNERS: NEW UNIT APPLICATIONS

    EPA Science Inventory

    The report describes a study to define boiler modifications required to achieve 70% SO2 removal with sorbent injection on a large tangentially fired utility boiler without supplemental spray drying. The study is a follow on to a recently completed broader evaluation of boiler des...

  15. Boiling process modelling peculiarities analysis of the vacuum boiler

    NASA Astrophysics Data System (ADS)

    Slobodina, E. N.; Mikhailov, A. G.

    2017-06-01

    The analysis of the low and medium powered boiler equipment development was carried out, boiler units possible development directions with the purpose of energy efficiency improvement were identified. Engineering studies for the vacuum boilers applying are represented. Vacuum boiler heat-exchange processes where boiling water is the working body are considered. Heat-exchange intensification method under boiling at the maximum heat- transfer coefficient is examined. As a result of the conducted calculation studies, heat-transfer coefficients variation curves depending on the pressure, calculated through the analytical and numerical methodologies were obtained. The conclusion about the possibility of numerical computing method application through RPI ANSYS CFX for the boiling process description in boiler vacuum volume was given.

  16. Increase of efficiency and reliability of liquid fuel combustion in small-sized boilers

    NASA Astrophysics Data System (ADS)

    Roslyakov, P. V.; Proskurin, Yu V.; Ionkin, I. L.

    2017-11-01

    One of the ways to increase the efficiency of using fuels is to create highly efficient domestic energy equipment, in particular small-sized hot-water boilers in autonomous heating systems. Increasing the efficiency of the boiler requires a reduction in the temperature of the flue gases leaving, which, in turn, can be achieved by installing additional heating surfaces. The purpose of this work was to determine the principal design solutions and to develop a draft design for a high-efficiency 3-MW hot-water boiler using crude oil as its main fuel. Ensuring a high efficiency of the boiler is realized through the use of an external remote economizer, which makes it possible to reduce the dimensions of the boiler, facilitate the layout of equipment in a limited size block-modular boiler house and virtually eliminate low-temperature corrosion of boiler heat exchange surfaces. In the article the variants of execution of the water boiler and remote economizer are considered and the preliminary design calculations of the remote economizer for various schemes of the boiler layout in the Boiler Designer software package are made. Based on the results of the studies, a scheme was chosen with a three-way boiler and a two-way remote economizer. The design of a three-way fire tube hot water boiler and an external economizer with an internal arrangement of the collectors, providing for its location above the boiler in a block-modular boiler house and providing access for servicing both a remote economizer and a hot water boiler, is proposed. Its mass-dimensional and design parameters are determined. In the software package Boiler Designer thermal, hydraulic and aerodynamic calculations of the developed fire tube boiler have been performed. Optimization of the boiler design was performed, providing the required 94% efficiency value for crude oil combustion. The description of the developed flue and fire-tube hot water boiler and the value of the main design and technical and economic parameters are given.

  17. Study of flue-gas temperature difference in supercritical once-through boiler

    NASA Astrophysics Data System (ADS)

    Kang, Yanchang; Li, Bing; Song, Ang

    2018-02-01

    The 600 MW coal-fired once-through Boilers with opposed firing at a power plant are found to experience marked temperature variation and even overtemperature on the wall of the heating surface as a result of flue-gas temperature (FGT) variation in the boiler. In this study, operational adjustments were made to the pulverizing, combustion, and secondary air box systems in these boilers, in order to solve problems in internal combustion. The adjustments were found to reduce FGT difference and optimize the boiler’ combustion conditions. The results of this study can provide a reference for optimization of coal-fired boiler of the same type in similar conditions.

  18. Simulation study on the maximum continuous working condition of a power plant boiler

    NASA Astrophysics Data System (ADS)

    Wang, Ning; Han, Jiting; Sun, Haitian; Cheng, Jiwei; Jing, Ying'ai; Li, Wenbo

    2018-05-01

    First of all, the boiler is briefly introduced to determine the mathematical model and the boundary conditions, then the boiler under the BMCR condition numerical simulation study, and then the BMCR operating temperature field analysis. According to the boiler actual test results and the hot BMCR condition boiler output test results, the simulation results are verified. The main conclusions are as follows: the position and size of the inscribed circle in the furnace and the furnace temperature distribution and test results under different elevation are compared and verified; Accuracy of numerical simulation results.

  19. a Study of Using Hydrogen Gas for Steam Boiler in CHOLOR- Alkali Manufacturing

    NASA Astrophysics Data System (ADS)

    Peantong, Sasitorn; Tangjitsitcharoen, Somkiat

    2017-06-01

    Main products of manufacturing of Cholor - Alkali, which commonly known as industrial chemical, are chlorine gas (Cl2), Sodium Hydroxide (NaOH) and hydrogen gas (H2). Chorine gas and sodium hydroxide are two main products for commercial profit; where hydrogen gas is by product. Most industries release hydrogen gas to atmosphere as it is non-profitable and less commercial scale. This study aims to make the most use of hydrogen as a substitute energy of natural gas for steam boiler to save energy cost. The second target of this study is to reduce level of CO2 release to air as a consequence of boiler combustion. This study suggests to install boiler that bases on hydrogen as main power with a high turndown ratio of at least 1:6. However, this case study uses boiler with two mode such as natural gas (NG) mode and mixed mode as they need to be flexible for production. Never the less, the best boiler selection is to use single mode energy of hydrogen. The most concerned issue about hydrogen gas is explosion during combustion stage. Stabilization measures at emergency stop is introduced to control H2 pressure to protect the explosion. This study varies ratio of natural gas to hydrogen gas to find the optimal level of two energy sources for boiler and measure total consumption through costing model; where CO2 level is measured at the boiler stack. The result of this study shows that hydrogen gas can be a substitute energy with natural gas and can reduce cost. Natural gas cost saving is 248,846 baht per month and reduce level of NOx is 80 ppm 7% O2 and 2 % of CO2 release to air as a consequence of boiler combustion.

  20. Influence of burner form and pellet type on domestic pellet boiler performance

    NASA Astrophysics Data System (ADS)

    Rastvorov, D. V.; Osintsev, K. V.; Toropov, E. V.

    2017-10-01

    The study presents combustion and emission results obtained using two serial pellet boilers of the same heating capacity 40 kW. These boilers have been designed by producers for domestic conditions of exploitation. The principal difference between boilers was the type of the burner. The study concerns the efficiency and ecological performance difference between burners of circular and rectangular forms. The features of the combustion process in both types of burners were studied when boiler operated with different sorts of pellets. The results suggest that the burner of circular form excels the rectangular form burner. However, there is some difference of NOx emission between circular and rectangular burners.

  1. A Study of Waste-Heat-Boiler Size and Performance of a Conceptual Marine COGAS System.

    DTIC Science & Technology

    1980-02-01

    The addition of a waste-heat boiler which extracts heat from the gas turbine exhaust gas to operate a bottoming Rankine cycle is one way to improve the...do not change significantly. Higher saturation pressure actually results in a somewhat lower boiler heat transfer, but the Rankine - cycle performance...of heat transferred in the waste-heat boiler and (2) the conversion efficiency of the Rankine cycle . In sizing the waste-heat boiler, attention was

  2. Performances of condensation boilers of the dry type observed in the laboratory and in operation (in French)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pelloux-Prayer, D.; Rottenberg, J.; Ours, A.

    1982-01-01

    Studies have shown that the dry type of condensation boiler offers substantial energy savings in residential space heating. For collective heating, laboratory efficiencies of 85-95% were confirmed in the field by a condensation boiler operating in a 75-unit apartment house. Compared with conventional boilers, the condensation type uses 15-21% less energy. Retrofitting existing boilers involves routing the flue gas through a heat exchanger placed in the return-water system and providing drainage for the condensates.

  3. Assessment of physical workload in boiler operations.

    PubMed

    Rodrigues, Valéria Antônia Justino; Braga, Camila Soares; Campos, Julio César Costa; Souza, Amaury Paulo de; Minette, Luciano José; Sensato, Guilherme Luciano; Moraes, Angelo Casali de; Silva, Emília Pio da

    2012-01-01

    The use of boiler wood-fired is fairly common equipment utilized in steam generation for energy production in small industries. The boiler activities are considered dangerous and heavy, mainly due to risks of explosions and the lack of mechanization of the process. This study assessed the burden of physical labor that operators of boilers are subjected during the workday. Assessment of these conditions was carried out through quantitative and qualitative measurements. A heart rate monitor, a wet-bulb globe thermometer (WBGT), a tape-measure and a digital infrared camera were the instruments used to collect the quantitative data. The Nordic Questionnaire and the Painful Areas Diagram were used to relate the health problems of the boiler operator with activity. With study, was concluded that the boiler activity may cause pains in the body of intensity different, muscle fatigue and diseases due to excessive weight and the exposure to heat. The research contributed to improve the boiler operator's workplace and working conditions.

  4. Building America Case Study: Advanced Boiler Load Monitoring Controllers, Chicago, Illinois (Fact Sheet)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    PARR

    Beyond these initial system efficiency upgrades are an emerging class of Advanced Load Monitoring (ALM) aftermarket controllers that dynamically respond to the boiler load, with claims of 10% to 30% of fuel savings over a heating season. For hydronic boilers specifically, these devices perform load monitoring, with continuous measurement of supply and in some cases return water temperatures. Energy savings from these ALM controllers are derived from dynamic management of the boiler differential, where a microprocessor with memory of past boiler cycles prevents the boiler from firing for a period of time, to limit cycling losses and inefficient operation duringmore » perceived low load conditions. These differ from OTR controllers, which vary boiler setpoint temperatures with ambient conditions while maintaining a fixed differential. PARR installed and monitored the performance of one type of ALM controller, the M2G from Greffen Systems, at multifamily sites in the city of Chicago and its suburb Cary, IL, both with existing OTR control. Results show that energy savings depend on the degree to which boilers are over-sized for their load, represented by cycling rates. Also savings vary over the heating season with cycling rates, with greater savings observed in shoulder months. Over the monitoring period, over-sized boilers at one site showed reductions in cycling and energy consumption in line with prior laboratory studies, while less over-sized boilers at another site showed muted savings.« less

  5. FETC/EPRI Biomass Cofiring Cooperative Agreement. Quarterly technical report, September 26-December 31, 1996

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hughes, E. Tillman, D.

    1997-12-01

    Biomass utilization to reduce fossil C0{sub 2} emissions is being supported by sixteen (16) EPRI research projects, each contributing to the commercialization of systems to address greenhouse gas emissions. These projects include: (1) cofiring combustion testing at the Seward Generating Station of GPU Genco; (2) fuel preparation testing at the Greenidge Generating Station of NYSEG; (3) precommercial testing of cofiring at the Allen and Colbert Fossil Plants of TVA; (4) testing of switchgrass cofiring at the Blount St. Station of Madison Gas & Electric; (5) high percentage biomass cofiring with Southern Company; (6) urban wood waste cofiring at the supercriticalmore » cyclone boiler at Michigan City Generating Station of Northern Indiana Public Service Co. (NIPSCO); (7) evaluation of switchgrass cofiring with Nebraska Public Power District at Sandia National Laboratories in Livermore, CA; (8) waste plastics cofiring with Duke Power in a tangentially-fired pulverized coal (PC) boiler; (9) cofiring a mixture of plastics, fiber, and pulp industry wastes with South Carolina Electric and Gas; (10) urban wood waste cofiring evaluation and testing by the University of Pittsburgh in stoker boilers; (11) assessment of toxic emissions from cofiring of wood and coal; (12) development of fuel and power plant models for analysis and interpretation of cofiring results; (13) analysis of C0{sub 2} utilization in algal systems for wastewater treatment; (14) combustion testing and combustor development focusing on high percentage cofiring; (15) analysis of problems and potential solutions to the sale of flyash from coal- fired boilers practicing cofiring; and (16) analysis of C0{sub 2} capture and disposal systems. EPRI is supported in these efforts by numerous contractors including: Foster Wheeler Environmental Corporation, Battelle Columbus Laboratories, New York State Electric and Gas Co., Tennessee Valley Authority (TVA), NIPSCO, the University of Pittsburgh, John Benneman, and others. These projects address various aspects of cofiring for C0{sub 2} mitigation including testing of cofiring with various fuels, and in all types of boilers; development of analytical tools to support the cofiring assessment; addressing specific barriers to cofiring such as the sale of flyash; longer term technology development; and evaluating alternative methods for C0{sub 2} mitigation. Taken together, they address the critical concerns associated with this approach to biofuel utilization. As such, they support implementation of the most promising near-term approach to biomass usage for greenhouse gas mitigation. This report contains a brief description of each project. It then reports the progress made during the first quarter of the contract, focusing upon test results from the Allen Fossil Plant, where precommercial testing at a cyclone boiler was used to evaluate particle size and NO{sub x} emissions from cofiring.« less

  6. Coal-Fired Boilers at Navy Bases, Navy Energy Guidance Study, Phase II and III.

    DTIC Science & Technology

    1979-05-01

    several sizes were performed. Central plants containing four equal-sized boilers and central flue gas desulfurization facilities were shown to be less...Conceptual design and parametric cost studies of steam and power generation systems using coal-fired stoker boilers and stack gas scrubbers in

  7. Bench-Scale Silicone Process for Low-Cost CO{sub 2} Capture

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vipperla, Ravikumar; Yee, Michael; Steele, Ray

    This report presents system and economic analysis for a carbon capture unit which uses an amino-silicone solvent for CO{sub 2} capture and sequestration (CCS) in a pulverized coal (PC) boiler. The amino-silicone solvent is based on GAP-1 with Tri-Ethylene Glycol (TEG) as a co-solvent. The report also shows results for a CCS unit based on a conventional approach using mono-ethanol amine (MEA). Models were developed for both processes and used to calculate mass and energy balances. Capital costs and energy penalty were calculated for both systems, as well as the increase in cost of electricity. The amino-silicone solvent based systemmore » demonstrates significant advantages compared to the MEA system.« less

  8. Effect of Pellet Boiler Exhaust on Secondary Organic Aerosol Formation from α-Pinene.

    PubMed

    Kari, Eetu; Hao, Liqing; Yli-Pirilä, Pasi; Leskinen, Ari; Kortelainen, Miika; Grigonyte, Julija; Worsnop, Douglas R; Jokiniemi, Jorma; Sippula, Olli; Faiola, Celia L; Virtanen, Annele

    2017-02-07

    Interactions between anthropogenic and biogenic emissions, and implications for aerosol production, have raised particular scientific interest. Despite active research in this area, real anthropogenic emission sources have not been exploited for anthropogenic-biogenic interaction studies until now. This work examines these interactions using α-pinene and pellet boiler emissions as a model test system. The impact of pellet boiler emissions on secondary organic aerosol (SOA) formation from α-pinene photo-oxidation was studied under atmospherically relevant conditions in an environmental chamber. The aim of this study was to identify which of the major pellet exhaust components (including high nitrogen oxide (NO x ), primary particles, or a combination of the two) affected SOA formation from α-pinene. Results demonstrated that high NO x concentrations emitted by the pellet boiler reduced SOA yields from α-pinene, whereas the chemical properties of the primary particles emitted by the pellet boiler had no effect on observed SOA yields. The maximum SOA yield of α-pinene in the presence of pellet boiler exhaust (under high-NO x conditions) was 18.7% and in the absence of pellet boiler exhaust (under low-NO x conditions) was 34.1%. The reduced SOA yield under high-NO x conditions was caused by changes in gas-phase chemistry that led to the formation of organonitrate compounds.

  9. Exergy analysis on industrial boiler energy conservation and emission evaluation applications

    NASA Astrophysics Data System (ADS)

    Li, Henan

    2017-06-01

    Industrial boiler is one of the most energy-consuming equipments in china, the annual consumption of energy accounts for about one-third of the national energy consumption. Industrial boilers in service at present have several severe problems such as small capacity, low efficiency, high energy consumption and causing severe pollution on environment. In recent years, our country in the big scope, long time serious fog weather, with coal-fired industrial boilers is closely related to the regional characteristics of high strength and low emissions [1]. The energy-efficient and emission-reducing of industry boiler is of great significance to improve China’s energy usage efficiency and environmental protection. Difference in thermal equilibrium theory is widely used in boiler design, exergy analysis method is established on the basis of the first law and second law of thermodynamics, by studying the cycle of the effect of energy conversion and utilization, to analyze its influencing factors, to reveal the exergy loss of location, distribution and size, find out the weak links, and a method of mining system of the boiler energy saving potential. Exergy analysis method is used for layer combustion boiler efficiency and pollutant emission characteristics analysis and evaluation, and can more objectively and accurately the energy conserving potential of the mining system of the boiler, find out the weak link of energy consumption, and improve equipment performance to improve the industrial boiler environmental friendliness.

  10. Factors affecting stress assisted corrosion cracking of carbon steel under industrial boiler conditions

    NASA Astrophysics Data System (ADS)

    Yang, Dong

    Failure of carbon steel boiler tubes from waterside has been reported in the utility boilers and industrial boilers for a long time. In industrial boilers, most waterside tube cracks are found near heavy attachment welds on the outer surface and are typically blunt, with multiple bulbous features indicating a discontinuous growth. These types of tube failures are typically referred to as stress assisted corrosion (SAC). For recovery boilers in the pulp and paper industry, these failures are particularly important as any water leak inside the furnace can potentially lead to smelt-water explosion. Metal properties, environmental variables, and stress conditions are the major factors influencing SAC crack initation and propagation in carbon steel boiler tubes. Slow strain rate tests (SSRT) were conducted under boiler water conditions to study the effect of temperature, oxygen level, and stress conditions on crack initation and propagation on SA-210 carbon steel samples machined out of boiler tubes. Heat treatments were also performed to develop various grain size and carbon content on carbon steel samples, and SSRTs were conducted on these samples to examine the effect of microstructure features on SAC cracking. Mechanisms of SAC crack initation and propagation were proposed and validated based on interrupted slow strain tests (ISSRT). Water chemistry guidelines are provided to prevent SAC and fracture mechanics model is developed to predict SAC failure on industrial boiler tubes.

  11. Field Test of Boiler Primary Loop Temperature Controller

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glanville, P.; Rowley, P.; Schroeder, D.

    Beyond these initial system efficiency upgrades are an emerging class of Advanced Load Monitoring (ALM) aftermarket controllers that dynamically respond to the boiler load, with claims of 10% to 30% of fuel savings over a heating season. For hydronic boilers specifically, these devices perform load monitoring, with continuous measurement of supply and in some cases return water temperatures. Energy savings from these ALM controllers are derived from dynamic management of the boiler differential, where a microprocessor with memory of past boiler cycles prevents the boiler from firing for a period of time, to limit cycling losses and inefficient operation duringmore » perceived low load conditions. These differ from OTR controllers, which vary boiler setpoint temperatures with ambient conditions while maintaining a fixed differential. PARR installed and monitored the performance of one type of ALM controller, the M2G from Greffen Systems, at multifamily sites in the city of Chicago and its suburb Cary, IL, both with existing OTR control. Results show that energy savings depend on the degree to which boilers are over-sized for their load, represented by cycling rates. Also savings vary over the heating season with cycling rates, with greater savings observed in shoulder months. Over the monitoring period, over-sized boilers at one site showed reductions in cycling and energy consumption in line with prior laboratory studies, while less over-sized boilers at another site showed muted savings.« less

  12. Heat and momentum transfer model studies applicable to once-through, forced convection potassium boiling

    NASA Technical Reports Server (NTRS)

    Sabin, C. M.; Poppendiek, H. F.

    1971-01-01

    A number of heat transfer and fluid flow mechanisms that control once-through, forced convection potassium boiling are studied analytically. The topics discussed are: (1) flow through tubes containing helical wire inserts, (2) motion of droplets entrained in vapor flow, (3) liquid phase distribution in boilers, (4) temperature distributions in boiler tube walls, (5) mechanisms of heat transfer regime change, and (6) heat transfer in boiler tubes. Whenever possible, comparisons of predicted and actual performances are made. The model work presented aids in the prediction of operating characteristics of actual boilers.

  13. Joint Long-Range Energy Study for Greater Fairbanks Military Complex

    DTIC Science & Technology

    2005-02-01

    be viewed as a two - stage processor of a fuel or feedstock. The feedstock is first gasified using high-temperature plasma heating sys- tems at...Coal-Fired Boilers with New Circulating Fluidized- Bed Boilers (CFBs). EAFB anticipates replacing two current boilers with two new boilers. This...definition to support DD Form 1391 budget level cost estimates for new coal-fired CHPPs at FWA and EAFB and for two new coal-fired CFBs at EAFB • update

  14. Design of Boiler Welding for Improvement of Lifetime and Cost Control.

    PubMed

    Thong-On, Atcharawadi; Boonruang, Chatdanai

    2016-11-03

    Fe-2.25Cr-1Mo a widely used material for headers and steam tubes of boilers. Welding of steam tube to header is required for production of boiler. Heat affected zone of the weld can have poor mechanical properties and poor corrosion behavior leading to weld failure. The cost of material used for steam tube and header of boiler should be controlled. This study propose a new materials design for boiler welding to improve the lifetime and cost control, using tungsten inert gas (TIG) welding of Fe-2.25Cr-1Mo tube to carbon steel pipe with chromium-containing filler. The cost of production could be reduced by the use of low cost material such as carbon steel pipe for boiler header. The effect of chromium content on corrosion behavior of the weld was greater than that of the microstructure. The lifetime of the welded boiler can be increased by improvement of mechanical properties and corrosion behavior of the heat affected zone.

  15. Design of Boiler Welding for Improvement of Lifetime and Cost Control

    PubMed Central

    Thong-On, Atcharawadi; Boonruang, Chatdanai

    2016-01-01

    Fe-2.25Cr-1Mo a widely used material for headers and steam tubes of boilers. Welding of steam tube to header is required for production of boiler. Heat affected zone of the weld can have poor mechanical properties and poor corrosion behavior leading to weld failure. The cost of material used for steam tube and header of boiler should be controlled. This study propose a new materials design for boiler welding to improve the lifetime and cost control, using tungsten inert gas (TIG) welding of Fe-2.25Cr-1Mo tube to carbon steel pipe with chromium-containing filler. The cost of production could be reduced by the use of low cost material such as carbon steel pipe for boiler header. The effect of chromium content on corrosion behavior of the weld was greater than that of the microstructure. The lifetime of the welded boiler can be increased by improvement of mechanical properties and corrosion behavior of the heat affected zone. PMID:28774014

  16. Development of combined low-emissions burner devices for low-power boilers

    NASA Astrophysics Data System (ADS)

    Roslyakov, P. V.; Proskurin, Yu. V.; Khokhlov, D. A.

    2017-08-01

    Low-power water boilers are widely used for autonomous heat supply in various industries. Firetube and water-tube boilers of domestic and foreign manufacturers are widely represented on the Russian market. However, even Russian boilers are supplied with licensed foreign burner devices, which reduce their competitiveness and complicate operating conditions. A task of developing efficient domestic low-emissions burner devices for low-power boilers is quite acute. A characteristic property of ignition and fuel combustion in such boilers is their flowing in constrained conditions due to small dimensions of combustion chambers and flame tubes. These processes differ significantly from those in open combustion chambers of high-duty power boilers, and they have not been sufficiently studied yet. The goals of this paper are studying the processes of ignition and combustion of gaseous and liquid fuels, heat and mass transfer and NO x emissions in constrained conditions, and the development of a modern combined low-emissions 2.2 MW burner device that provides efficient fuel combustion. A burner device computer model is developed and numerical studies of its operation on different types of fuel in a working load range from 40 to 100% of the nominal are carried out. The main features of ignition and combustion of gaseous and liquid fuels in constrained conditions of the flame tube at nominal and decreased loads are determined, which differ fundamentally from the similar processes in steam boiler furnaces. The influence of the burner devices design and operating conditions on the fuel underburning and NO x formation is determined. Based on the results of the design studies, a design of the new combined low-emissions burner device is proposed, which has several advantages over the prototype.

  17. Economic Benefit of Coal Utilization/Conversion at Air Force Bases: Screening Study

    DTIC Science & Technology

    1989-08-01

    fire-tLbe) boilers that are small enough to be shipped by rail. The field-erected units are larger, water- tube boilers. The pulverized coal-fired and...circulating FBC boilers considered are field-erected, water- tube boilers. Pollution control technology costs were considered to a limited extent. All...Coal/H 0 mix (S/MBtu) = 3.00 OPTIONS Cal/oil mix (S/MBtu) 3.50 Soot blower multiplier = 0.0 Tube bank mod multiplier = 1.0 Primary fuel is 1 Bottom ash

  18. Advanced CFD modelling of air and recycled flue gas staging in a waste wood-fired grate boiler for higher combustion efficiency and greater environmental benefits.

    PubMed

    Rajh, Boštjan; Yin, Chungen; Samec, Niko; Hriberšek, Matjaž; Kokalj, Filip; Zadravec, Matej

    2018-07-15

    Grate-fired boilers are commonly used to burn biomass/wastes for heat and power production. In spite of the recent breakthrough in integration of advanced secondary air systems in grate boilers, grate-firing technology needs to be advanced for higher efficiency and lower emissions. In this paper, innovative staging of combustion air and recycled flue gas in a 13 MW th waste wood-fired grate boiler is comprehensively studied based on a numerical model that has been previously validated. In particular, the effects of the jet momentum, position and orientation of the combustion air and recycled flue gas streams on in-furnace mixing, combustion and pollutant emissions from the boiler are examined. It is found that the optimized air and recycled flue gas jets remarkably enhance mixing and heat transfer, result in a more uniform temperature and velocity distribution, extend the residence time of the combustibles in the hot zone and improve burnout in the boiler. Optimizing the air and recycled flue gas jet configuration can reduce carbon monoxide emission from the boiler by up to 86%, from the current 41.0 ppm to 5.7 ppm. The findings of this study can serve as useful guidelines for novel design and optimization of the combustion air supply and flue gas recycling for grate boilers of this type. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Study on Laws, Regulations and Standards on Energy Efficiency, Energy Conserving and Emission Reduction of Industrial Boilers in EU

    NASA Astrophysics Data System (ADS)

    Liu, Ren; Zhao, Yuejin; Chen, Haihong; Liang, Xiuying; Yang, Ming

    2017-12-01

    Industrial boilers are widely applied in such fields as factory power, building heating, and people’s lives; China is the world’s largest producer and user of industrial boilers, with very high annual energy consumption; clear requirements have been put forward by China on the energy efficiency since the “11th Five-year Plan” with the hope to save energy and reduce emission by means of energy efficiency standards and regulations on the supervision and control of various special equipment. So far, the energy efficiency of industrial boilers in China has been improved significantly but there is still a gap with the EU states. This paper analyzes the policies of energy efficiency, implementation models and methods of supervision and implementation at the EU level from laws, regulations, directives as well as standards; the paper also puts forward suggestions of energy conserving and emission reduction on the improvement of energy conserving capacity of industrial boilers in China through studying the legislations and measures of the developed countries in energy conserving of boilers.

  20. PAH emissions from old and new types of domestic hot water boilers.

    PubMed

    Horak, Jiri; Kubonova, Lenka; Krpec, Kamil; Hopan, Frantisek; Kubesa, Petr; Motyka, Oldrich; Laciok, Vendula; Dej, Milan; Ochodek, Tadeas; Placha, Daniela

    2017-06-01

    Five different domestic heating boilers (automatic, over-fire, with down-draft combustion and gasification) and three types of fuel (lignite, wood and mixed fuel) were examined in 25 combustion tests and correlated with the emissions of particulate matter (PM), carbon monoxide (CO), total organic carbon (TOC) and 12 polycyclic aromatic hydrocarbons (PAHs with MW = 178-278 g/mol) focusing on particle phase. However, the distribution of 12 PAHs in gas phase was considered as well due to the presence mainly of lighter PAHs in gas phase. The PAHs, as well as the CO and TOC, are the indicators of incomplete combustion, and in this study PAH emission increased significantly with increasing emissions of CO and TOC. The PAHs were mainly detected on PM 2.5 , their contents were increasing linearly with increasing PM 2.5 emissions. The highest emission factors of PAHs were measured for boilers of old construction, such as over-fire boiler (5.8-929 mg/kg) and boiler with down-draft combustion (3.1-54.1 mg/kg). Modern types of boilers produced much lower emissions of PAHs, in particular, automatic boiler (0.3-3.3 mg/kg) and gasification boilers (0.2-6.7 mg/kg). In general, the inefficient combustion at reduced output of boilers generated 1.4-17.7 times more emissions of PAHs than the combustion at nominal output of boilers. It is recommended to operate boilers at nominal output with sufficient air supply and to use the proper fuel to minimise PAHs emissions from domestic heating appliances. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Emission characteristics of NOx, CO, NH3 and VOCs from gas-fired industrial boilers based on field measurements in Beijing city, China

    NASA Astrophysics Data System (ADS)

    Yue, Tao; Gao, Xiang; Gao, Jiajia; Tong, Yali; Wang, Kun; Zuo, Penglai; Zhang, Xiaoxi; Tong, Li; Wang, Chenlong; Xue, Yifeng

    2018-07-01

    In the past decade, due to the management policies and coal combustion controls in Beijing, the consumption of natural gas has increased gradually. Nevertheless, the research on the emission characteristics of gaseous pollutants emitted from gas-fired industrial boilers, especially considering the influence of low nitrogen (low-NOx) retrofit policy of gas boilers, is scarcely. In this study, based on literature and field investigations, onsite measurements of NOx, CO, NH3 and VOCs (Volatile Organic Compounds) emissions from gas-fired industrial boilers as well as the key factors that affected the emission of gaseous pollutants were discussed. Category-specific emission factors (EFs) of NOx, CO, NH3 and VOCs were obtained from the field measurements of 1107 "low-NOx" retrofitted and unabated gas-fired industrial boilers. Our results showed that operating load and control measures were the two key factors affecting the formation of gaseous pollutants. The EFs of NOx (EFNOx) and CO (EFCO) of atmospheric combustion boilers (ACBs) were much higher than the EFs of chamber combustion boilers (CCBs). The total emissions of NOx, CO, NH3 and VOCs from gas-fired industrial boilers in Beijing in the year of 2015 were estimated at 10489.6 t, 3272.8 t, 196.4 t and 235.4 t, respectively. Alkanes, BTEX, oxygenated VOCs and non-reactive organic matter were the four main chemical components of VOCs. As for the spatial distributions, the emissions of NOx, CO, NH3 and VOCs from gas-fired industrial boilers in Beijing were predominantly concentrated in central six urban districts. In the future, more detailed investigation and field tests for all kinds of gas-fired industrial boilers are still greatly needed to achieve more reliable estimations of atmospheric pollutants from gas-fired industrial boilers.

  2. [Emission characteristics of fine particles from grate firing boilers].

    PubMed

    Wang, Shu-Xiao; Zhao, Xiu-Juan; Li, Xing-Hua; Wei, Wei; Hao, Ji-Ming

    2009-04-15

    Grate firing boilers are the main type of Chinese industrial boilers, which accounts for 85% of the industrial boilers and is one of the most important emission sources of primary air pollutants in China. In this study, five boilers in three cities were selected and tested to measure the emission characteristics of PM2.5, and gaseous pollutants were applied by a compact dilution sampling system, which was developed for this field study. Results showed that particles mass size distributions for the five industrial boilers presented single peak or double peak, former peaks near 0.14 microm and the later peaks after 1.0 microm; the cyclone dust remover and wet scrubber dust remover had effective removal efficiencies not only to PM2.5, but also to PM1.0; and under the condition of same control techniques, grate firing boiler with high capacity has less PM2.5 emission than the boiler with low capacity. In the PM2.5 collected from flue gases, SO4(2-) was the most abundant ion, accounted for 20%-40% of the PM2.5; and C was the most abundant element (7.5%-31.8%), followed by S (8.4%-18.7%). Carbon balance method was applied to calculate the emission factors of these pollutants. The emission factors of PM2.5, NO, and SO2 were in the range of 0.046-0.486 g x kg(-1), 1.63-2.47 g x kg(-1), 1.35-9.95 g x kg(-1) respectively. The results are useful for the emission inventory development of industrial boilers and the source analysis of PM2.5 in atmospheric environment.

  3. Development of Erosion-Corrosion-Resistant Cold-Spray Nanostructured Ni-20Cr Coating for Coal-Fired Boiler Applications

    NASA Astrophysics Data System (ADS)

    Kumar, M.; Singh, H.; Singh, N.; Chavan, N. M.; Kumar, S.; Joshi, S. V.

    2015-12-01

    The erosion-corrosion (E-C) behavior of a cold-spray nanostructured Ni-20Cr coating was studied under cyclic conditions in a coal-fired boiler. This study was done for 15 cycles (1500 h), in which each cycle comprised 100 h of heating in the boiler environment, followed by 1 h of cooling under ambient air conditions. The E-C extent was evaluated in terms of thickness loss data of the samples. The eroded-corroded samples were characterized using XRD, SEM/EDS, and x-ray mapping analyses. The nanostructured coating offered excellent E-C protection to boiler tube material (SA 516 steel) under harsh live conditions of the boiler. This E-C resistance offered by investigated coating may be attributed to the presence of protective NiO and Cr2O3 phases in its oxide scale and its superior as-sprayed microhardness.

  4. Materials for the pulp and paper industry. Section 1: Development of materials for black liquor recovery boilers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keiser, J.R.; Hubbard, C.R.; Payzant, E.A.

    1997-04-01

    Black liquor recovery boilers are essential components of kraft pulp and paper mills because they are a critical element of the system used to recover the pulping chemicals required in the kraft pulping process. In addition, the steam produced in these boilers is used to generate a significant portion of the electrical power used in the mill. Recovery boilers require the largest capital investment of any individual component of a paper mill, and these boilers are a major source of material problems in a mill. The walls and floors of these boilers are constructed of tube panels that circulate highmore » pressure water. Molten salts (smelt) accumulate on the floor of recovery boilers, and leakage of water into the boiler can result in a violent explosion when the leaked water instantly vaporizes upon contacting the molten smelt. Because corrosion of the conventionally-used carbon steel tubing was found to be excessive in the lower section of recovery boilers, use of stainless steel/carbon steel co-extruded tubing was adopted for boiler walls to lessen corrosion and reduce the likelihood of smelt/water explosions. Eventually, this co-extruded or composite (as it is known in the industry) tubing was selected for use as a portion or all of the floor of recovery boilers, particularly those operating at pressures > 6.2 MPa (900 psi), because of the corrosion problems encountered in carbon steel floor tubes. Since neither the cause of the cracking nor an effective solution has been identified, this program was established to develop a thorough understanding of the degradation that occurs in the composite tubing used for walls and floors. This is being accomplished through a program that includes collection and review of technical reports, examination of unexposed and cracked tubes from boiler floors, computer modeling to predict residual stresses under operating conditions, and operation of laboratory tests to study corrosion, stress corrosion cracking, and thermal fatigue.« less

  5. Evaluation of iron aluminide weld overlays for erosion - corrosion resistant boiler tube coatings in low NO{sub x} boilers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DuPont, J.N.; Banovic, S.W.; Marder, A.R.

    1996-08-01

    Low NOx burners are being installed in many fossil fired power plants in order to comply with new Clean Air Regulations. Due to the operating characteristics of these burners, boiler tube sulfidation corrosion is often enhanced and premature tube failures can occur. Failures due to oxidation and solid particle erosion are also a concern. A program was initiated in early 1996 to evaluate the use of iron aluminide weld overlays for erosion/corrosion protection of boiler tubes in Low NOx boilers. Composite iron/aluminum wires will be used with the Gas Metal Arc Welding (GMAW) process to prepare overlays on boiler tubesmore » steels with aluminum contents from 8 to 16wt%. The weldability of the composite wires will be evaluated as a function of chemical composition and welding parameters. The effect of overlay composition on corrosion (oxidation and sulfidation) and solid particle erosion will also be evaluated. The laboratory studies will be complemented by field exposures of both iron aluminide weld overlays and co-extruded tubing under actual boiler conditions.« less

  6. Study of Nox Emission Characteristics of a 1025t/h Coal-Fired Circulating Fluidized Bed Boiler

    NASA Astrophysics Data System (ADS)

    Li, Q. Y.; Mi, Z. D.; Zhang, Q. F.

    Measurements of emission are carried out in a 1025t/h CFB boiler. The effect of some factors including coal properties, bed temperature, unit load, excess air on the emission of NOx are investigated. The measurement results show that the N concentration in the coal is dominant parameter to predict the NOx emission from a large-scale CFB boiler. NOx emission from the 1025t/h CFB boiler increases with cyclone temperature and upper pressure drop due to post combustion and external cycle.

  7. Vacuum boilers developed heating surfaces technic and economic efficiency evaluation

    NASA Astrophysics Data System (ADS)

    Slobodina, E. N.; Mikhailov, A. G.; Semenov, B. A.

    2018-01-01

    The vacuum boilers as manufacturing proto types application analysis was carried out, the possible directions for the heating surfaces development are identified with a view to improving the energy efficiency. Economic characteristics to evaluate the vacuum boilers application efficiency (Net Discounted Income (NDI), Internal Rate of Return (IRR), Profitability Index (PI) and Payback Period) are represented. The given type boilers application technic and economic efficiency criteria were established. NDI changing curves depending on the finning coefficient and operating pressure were obtained as a result of the conducted calculation studies.

  8. Systematic Field Study of NO(x) Emission Control Methods for Utility Boilers.

    ERIC Educational Resources Information Center

    Bartok, William; And Others

    A utility boiler field test program was conducted. The objectives were to determine new or improved NO (x) emission factors by fossil fuel type and boiler design, and to assess the scope of applicability of combustion modification techniques for controlling NO (x) emissions from such installations. A statistically designed test program was…

  9. Feasibility Study of Coal Gasification/Fuel Cell/Cogeneration Project, Fort Greely, Alaska Site. Preliminary Survey,

    DTIC Science & Technology

    1985-04-02

    sothat oilconsumptior ASME Boiler and Pressure Vessel Code . can be measured. Hot water boiler plants with out- U1I Shell-and-tube type exchangers are...slopes possible to VIII of the ASME Boiler and Pressure Vessel Code . prevent rain or melting snow from penetrating into (2? Water will flow through the

  10. Experimental Investigations of the Energy and Environmental Indices of Operation of a Low-Capacity Combined Gas Producer and Hot-Water Boiler

    NASA Astrophysics Data System (ADS)

    Bodnar, L. A.; Stepanov, D. V.; Dovgal‧, A. N.

    2015-07-01

    It has been shown that the introduction of combined gas producers and boilers on renewable energy sources is a pressing issue. A structural diagram of a low-capacity combined gas producer and boiler on renewable energy sources has been given; a bench and procedures for investigation and processing of results have been developed. Experimental investigations of the energy and environmental indices of a 40-kW combined gas producer and hotwater boiler burning wood have been carried out. Results of the experimental investigations have been analyzed. Distinctive features have been established and a procedure of thermal calculation of the double furnace of a lowcapacity combined gas producer and boiler burning solid fuel has been proposed. The calculated coefficients of heat transfer from the gases in the convection bank have been compared with the obtained experimental results. A calculation dependence for the heat transfer from the gases in convection banks of low-capacity hot-water boilers has been proposed. The quantities of harmful emissions from the combined gas producer and boiler on renewable energy sources have been compared with the existing Ukrainian and foreign standards. It has been established that the environmental efficiency of the boiler under study complies with most of the standard requirements of European countries.

  11. [Emission characteristics of PM10 from coal-fired industrial boiler].

    PubMed

    Li, Chao; Li, Xing-Hua; Duan, Lei; Zhao, Meng; Duan, Jing-Chun; Hao, Ji-Ming

    2009-03-15

    Through ELPI (electrical low-pressure impactor) based dilution sampling system, the emission characteristics of PM10 and PM2.5 was studied experimentally at the inlet and outlet of dust catchers at eight different coal-fired industrial boilers. Results showed that a peak existed at around 0.12-0.20 microm of particle size for both number size distribution and mass size distribution of PM10 emitted from most of the boilers. Chemical composition analysis indicated that PM2.5 was largely composed of organic carbon, elementary carbon, and sulfate, with mass fraction of 3.7%-21.4%, 4.2%-24.6%, and 1.5%-55.2% respectively. Emission factors of PM10 and PM2.5 measured were 0.13-0.65 kg x t(-1) and 0.08-0.49 kg x t(-1) respectively for grate boiler using raw coal, and 0.24 kg x t(-1) and 0.22 kg x t(-1) for chain-grate boiler using briquette. In comparison, the PM2.5 emission factor of fluidized bed boiler is 1.14 kg x t(-1), much her than that of grate boiler. Due to high coal consumption and low efficiency of dust separator, coal-fired industrial boiler may become the most important source of PM10, and should be preferentially controlled in China.

  12. Techno-economic analysis of wood biomass boilers for the greenhouse industry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chau, J.; Sowlati, T.; Sokhansanj, Shahabaddine

    2009-01-01

    The objective of this study is to perform a techno-economic analysis on a typical wood pellet and wood residue boiler for generation of heat to an average-sized greenhouse in British Columbia. The variables analyzed included greenhouse size and structure, boiler efficiency, fuel types, and source of carbon dioxide (CO2) for crop fertilization. The net present value (NPV) show that installing a wood pellet or a wood residue boiler to provide 40% of the annual heat demand is more economical than using a natural gas boiler to provide all the heat at a discount rate of 10%. For an assumed lifespanmore » of 25 years, a wood pellet boiler system could generate NPV of C$259,311 without electrostatic precipitator (ESP) and C$74,695 with ESP, respectively. While, installing a wood residue boiler with or without an ESP could provide NPV of C$919,922 or C$1,104,538, respectively. Using a wood biomass boiler could also eliminate over 3000 tonne CO2 equivalents of greenhouse gases annually. Wood biomass combustion generates more particulate matters than natural gas combustion. However, an advanced emission control system could significantly reduce particulate matters emission from wood biomass combustion which would bring the particulate emission to a relatively similar level as for natural gas.« less

  13. Thermal treatment and vitrification of boiler ash from a municipal solid waste incinerator.

    PubMed

    Yang, Y; Xiao, Y; Voncken, J H L; Wilson, N

    2008-06-15

    Boiler ash generated from municipal solid waste (MSW) incinerators is usually classified as hazardous materials and requires special disposal. In the present study, the boiler ash was characterized for the chemical compositions, morphology and microstructure. The thermal chemical behavior during ash heating was investigated with thermal balance. Vitrification of the ash was conducted at a temperature of 1400 degrees C in order to generate a stable silicate slag, and the formed slag was examined with chemical and mineralogical analyses. The effect of vitrification on the leaching characteristics of various elements in the ash was evaluated with acid leaching. The study shows that the boiler ash as a heterogeneous fine powder contains mainly silicate, carbonate, sulfates, chlorides, and residues of organic materials and heavy metal compounds. At elevated temperatures, the boiler ash goes through the initial moisture removal, volatilization, decomposition, sintering, melting, and slag formation. At 1400 degrees C a thin layer of salt melt and a homogeneous glassy slag was formed. The experimental results indicate that leaching values of the vitrified slag are significantly reduced compared to the original boiler ash, and the vitrification could be an interesting alternative for a safer disposal of the boiler ash. Ash compacting, e.g., pelletizing can reduce volatilization and weight loss by about 50%, and would be a good option for the feed preparation before vitrification.

  14. In-line particle measurement in a recovery boiler using high-speed infrared imaging

    NASA Astrophysics Data System (ADS)

    Siikanen, Sami; Miikkulainen, Pasi; Kaarre, Marko; Juuti, Mikko

    2012-06-01

    Black liquor is the fuel of Kraft recovery boilers. It is sprayed into the furnace of a recovery boiler through splashplate nozzles. The operation of a recovery boiler is largely influenced by the particle size and particle size distribution of black liquor. When entrained by upwards-flowing flue gas flow, small droplet particles may form carry-over and cause the fouling of heat transfer surfaces. Large droplet particles hit the char bed and the walls of the furnace without being dried. In this study, particles of black liquor sprays were imaged using a high-speed infrared camera. Measurements were done in a functional recovery boiler in a pulp mill. Objective was to find a suitable wavelength range and settings such as integration time, frame rate and averaging for the camera.

  15. 46 CFR 52.25-20 - Exhaust gas boilers.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false Exhaust gas boilers. 52.25-20 Section 52.25-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Other Boiler Types § 52.25-20 Exhaust gas boilers. Exhaust gas boilers with a maximum allowable working pressure...

  16. 46 CFR 52.25-20 - Exhaust gas boilers.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Exhaust gas boilers. 52.25-20 Section 52.25-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Other Boiler Types § 52.25-20 Exhaust gas boilers. Exhaust gas boilers with a maximum allowable working pressure...

  17. 46 CFR 52.25-20 - Exhaust gas boilers.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Exhaust gas boilers. 52.25-20 Section 52.25-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Other Boiler Types § 52.25-20 Exhaust gas boilers. Exhaust gas boilers with a maximum allowable working pressure...

  18. 46 CFR 52.25-20 - Exhaust gas boilers.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 2 2013-10-01 2013-10-01 false Exhaust gas boilers. 52.25-20 Section 52.25-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Other Boiler Types § 52.25-20 Exhaust gas boilers. Exhaust gas boilers with a maximum allowable working pressure...

  19. 46 CFR 52.25-20 - Exhaust gas boilers.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Exhaust gas boilers. 52.25-20 Section 52.25-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Other Boiler Types § 52.25-20 Exhaust gas boilers. Exhaust gas boilers with a maximum allowable working pressure...

  20. Apparatus and method of controlling the thermal performance of an oxygen-fired boiler

    DOEpatents

    Levasseur, Armand A.; Kang, Shin G.; Kenney, James R.; Edberg, Carl D.

    2017-09-05

    Disclosed herein is a method of controlling the operation of an oxy-fired boiler; the method comprising combusting a fuel in a boiler; producing a heat absorption pattern in the boiler; discharging flue gases from the boiler; recycling a portion of the flue gases to the boiler; combining a first oxidant stream with the recycled flue gases to form a combined stream; splitting the combined stream into several fractions; and introducing each fraction of the combined stream to the boiler at different points of entry to the boiler.

  1. Research and Development of Large Capacity CFB Boilers in TPRI

    NASA Astrophysics Data System (ADS)

    Xianbin, Sun; Minhua, Jiang

    This paper presents an overview of advancements of circulating fluidized bed (CFB) technology in Thermal Power Research Institute (TPRI),including technologies and configuration and progress of scaling up. For devoloping large CFB boiler, the CFB combustion test facilities have been established, the key technologies of large capacity CFB boiler have been research systematically, the 100MW ˜330MW CFB boiler have been developed and manufactured. The first domestically designed 100MW and 210MW CFB boiler have been put into commericial operation and have good operating performance. Domestic 330MW CFB boiler demonstration project also has been put into commericial operation,which is H type CFB boiler with Compact heat exchanger. This boiler is China's largest CFB boiler. The technical plan of domestic 600MW supercritical CFB boiler are also briefly introduced.

  2. Study of connected system of automatic control of load and operation efficiency of a steam boiler with extremal controller on a simulation model

    NASA Astrophysics Data System (ADS)

    Sabanin, V. R.; Starostin, A. A.; Repin, A. I.; Popov, A. I.

    2017-02-01

    The problems of operation effectiveness increase of steam boilers are considered. To maintain the optimum fuel combustion modes, it is proposed to use an extremal controller (EC) determining the value of airflow rate, at which the boiler generating the desired amount of heat will consume a minimum amount of fuel. EC sets the determined value of airflow rate to airflow rate controller (ARC). The test results of numerical simulation dynamic nonlinear model of steam boiler with the connected system of automatic control of load and combustion efficiency using EC are presented. The model is created in the Simulink modeling package of MATLAB software and can be used to optimize the combustion modes. Based on the modeling results, the conclusion was drawn about the possibility in principle of simultaneously boiler load control and optimizing by EC the combustion modes when changing the fuel combustion heat and the boiler characteristics and its operating mode. It is shown that it is possible to automatically control the operation efficiency of steam boilers when using EC without applying the standard flue gas analyzers. The article considers the numerical simulation dynamic model of steam boiler with the schemes of control of fuel consumption and airflow rate, the steam pressure and EC; the purpose of using EC in the scheme with linear controllers and the requirements to the quality of its operation; the results of operation of boiler control schemes without EC with estimation of influence of roughness of thermal mode maps on the nature of static and dynamic connection of the control units of fuel consumption and airflow rate; the phase trajectories and the diagrams of transient processes occurring in the control scheme with EC with stepped changing the fuel quality and boiler characteristics; analysis of modeling results and prospects for using EC in the control schemes of boilers.

  3. Stationary Engineers Apprenticeship. Related Training Modules. 12.1-12.9. Boilers.

    ERIC Educational Resources Information Center

    Lane Community Coll., Eugene, OR.

    This learning module, one in a series of 20 related training modules for apprentice stationary engineers, deals with boilers. Addressed in the individual instructional packages included in the module are the following topics: firetube and watertube boilers; boiler construction; procedures for operating and cleaning boilers; and boiler fittings,…

  4. 46 CFR 63.25-1 - Small automatic auxiliary boilers.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Small automatic auxiliary boilers. 63.25-1 Section 63.25... AUXILIARY BOILERS Requirements for Specific Types of Automatic Auxiliary Boilers § 63.25-1 Small automatic auxiliary boilers. Small automatic auxiliary boilers defined as having heat-input ratings of 400,000 Btu/hr...

  5. 77 FR 3966 - Approval and Promulgation of Air Quality Implementation Plans; Illinois; Regional Haze

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-26

    ... Midwest Generating--Baldwin Boilers 1, 2, and 3. Dominion Kincaid Generation--Boilers 1 and 2. Ameren.... Ameren Energy Generating--Duck Creek Boiler 1. Midwest Generation--Powerton Boilers 51, 52, 61, and 62. Midwest Generation--Joliet Boilers 71, 72, 81, and 82. Midwest Generation--Will County Boiler 4. City...

  6. Emission Characteristics of Gas-Fired Boilers based on Category-Specific Emission Factor from Field Measurements in Beijing, China

    NASA Astrophysics Data System (ADS)

    Itahashi, S.; Yan, X.; Song, G.; Yan, J.; Xue, Y.

    2017-12-01

    Gas-fired boilers will become the main stationary sources of NOx in Beijing. However, the knowledge of gas-fired boilers in Beijing is limited. In the present study, the emission characteristics of NOx, SO2, and CO from gas-fired boilers in Beijing were established using category-specific emission factors (EFs) from field measurements. In order to obtain category-specific EFs, boilers were classified through influence analysis. Factors such as combustion mode, boiler type, and installed capacity were considered critical for establishing EFs because they play significant roles in pollutant formation. The EFs for NOx, CO, and SO2 ranged from 1.42-6.86 g m-3, 0.05-0.67 g m-3 and 0.03-0.48 g m-3. The emissions of NOx, SO2, and CO for gas-fired boilers in Beijing were 11121 t, 468 t, and 222 t in 2014, respectively. The emissions were spatially allocated into grid cells with a resolution of 1 km × 1 km, and the results indicated that top emitters were in central Beijing. The uncertainties were quantified using a Monte Carlo simulation. The results indicated high uncertainties in CO (-157% to 154%) and SO2 (-127% to 182%) emissions, and relatively low uncertainties (-34% to 34%) in NOx emission. Furthermore, approximately 61.2% and 96.8% of the monitored chamber combustion boilers (CCBs) met the standard limits for NOx and SO2, respectively. Concerning NOx, low-NOx burners and NOx emission control measures are urgently needed for implementing of stricter standards. Adopting terminal control measures is unnecessary for SO2, although its concentration occasionally exceeds standard limits, because reduction of its concentration can be achieved thorough control of the sulfur content of natural gas at a stable low level. Furthermore, the atmospheric combustion boilers (ACBs) should be substituted with CCBs, because ACBs have a higher emission despite lower gross installed capacity. The results of this study will enable in understanding and controlling emissions from gas-fired boilers in Beijing.

  7. Heating boilers in Krakow, Poland: Options for improving efficiency and reducing emissions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cyklis, P.; Kowalski, J.; Kroll, J.

    1995-08-01

    In Krakow, Poland, coal-fired boilers are used to heat single apartment buildings and local heating districts. The population includes 2,930 small, hand-fired boilers and 227 larger traveling grate stoker-fired boilers. These boilers are important contributors to air quality problems in Krakow, and an assessment of their efficiency and emissions characteristics was recently undertaken. For the larger, stoker-fired boilers, efficiency was measured using a stack-loss method. In addition to the normal baseline fuel, the effects of coal cleaning and grading were evaluated. Testing was done at two selected sites. Boiler efficiencies were found to be low--50% to 67%. These boilers operatemore » without combustion controls or instrumentation for flue gas analysis. As a result, excess air levels are very high--up to 400%--leading to poor performance. Emissions were found to be typical for boilers of this type. Using the improved fuels yields reductions in emissions and improvement in efficiency when combined with proper adjustments. In the case of the hand-fired boilers, one set of cast-iron boilers and one set of steel boilers were tested. Efficiency in this case was measured using an input-output method for sets of three boilers taken together as a system. Emissions from these boilers are lowest when low volatile fuels, such as coke or smokeless briquettes, are used.« less

  8. 51. BOILER ROOM. SMALL BOILER ON LEFT OF UNKNOWN MANUFACTURE, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    51. BOILER ROOM. SMALL BOILER ON LEFT OF UNKNOWN MANUFACTURE, WITH INDUCTION MOTORS. HARTLEY BOILER, MONTGOMERY, ALABAMA, ON RIGHT. - Prattville Manufacturing Company, Number One, 242 South Court Street, Prattville, Autauga County, AL

  9. Fracture analysis of tube boiler for physical explosion accident.

    PubMed

    Kim, Eui Soo

    2017-09-01

    Material and failure analysis techniques are key tools for determining causation in case of explosive and bursting accident result from material and process defect of product in the field of forensic science. The boiler rupture generated by defect of the welding division, corrosion, overheating and degradation of the material have devastating power. If weak division of boiler burner is fractured by internal pressure, saturated vapor and water is vaporized suddenly. At that time, volume of the saturated vapor and water increases up to thousands of volume. This failure of boiler burner can lead to a fatal disaster. In order to prevent an explosion and of the boiler, it is critical to introduce a systematic investigation and prevention measures in advance. In this research, the cause of boiler failure is investigated through forensic engineering method. Specifically, the failure mechanism will be identified by fractography using scanning electron microscopes (SEM) and Optical Microscopes (OM) and mechanical characterizations. This paper presents a failure analysis of household welding joints for the water tank of a household boiler burner. Visual inspection was performed to find out the characteristics of the fracture of the as-received material. Also, the micro-structural changes such as grain growth and carbide coarsening were examined by optical microscope. Detailed studies of fracture surfaces were made to find out the crack propagation on the weld joint of a boiler burner. It was concluded that the rupture may be caused by overheating induced by insufficient water on the boiler, and it could be accelerated by the metal temperature increase. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rode, J.R.; Brzezeina, P.; Strach, F.

    This paper discusses the engineering considerations related to the design of a new 110 MWe atmospheric fluidized bed boiler (CFB) and boiler island auxiliaries for installation at the CEZ, a.s. (Czech Republic Utility) Ledvice Power Station. The plant is located in the northwest Bohemia area of the Czech Republic in the foothills of the Krusne Hory Mountains, between the towns of Bilina and Teplice. The type of fuel to be burned in the CFB is brown coal which requires unique design considerations in as well as the particular boiler operational parameters. The impetus behind the addition of this new CFBmore » at the plant is that the existing pulverized coal fired steam generator which was put in service in 1969 is unable to meet new regulations and laws regarding compliance with the protection of the environment and will be replaced once the new CFB unit is brought into service. A technical-economic study conducted by CEZ, a.s. evaluated CFB technology as the most advantageous from a long-term standpoint. The following variations were considered in the study: boiler retrofit and construction of new ash handling equipment; implementation of the combined cycle based upon natural gas; and reconstruction of the boiler equipment with transition to atmospheric fluid-bed combustion. The selection of the supplier of fluid-bed boiler was performed with an emphasis of the bidders` references as for the construction and operation of fluid-bed boilers with the outputs of min. 300 t/hr.« less

  11. Technology Solutions Case Study: Advanced Boiler Load Monitoring Controls, Chicago, Illinois

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2014-09-01

    Most of Chicago’s older multifamily housing stock is heated by centrally metered steam or hydronic systems. The cost of heat is typically absorbed into the owner’s operating cost and is then passed to tenants. Central boilers typically have long service lifetimes; the incentive for retrofit system efficiency upgrades is greater than equipment replacement for the efficiency-minded owner. System improvements as the “low-hanging fruit” are familiar, from improved pipe insulation to aftermarket controls such as outdoor temperature reset (OTR) or lead/lag controllers for sites with multiple boilers. Beyond these initial system efficiency upgrades are an emerging class of Advanced Load Monitoringmore » (ALM) aftermarket controllers that dynamically respond to the boiler load, with claims of 10% to 30% of fuel savings over a heating season. In this project, the Building America team Partnership for Advanced Residential Retrofit (PARR) installed and monitored an ALM aftermarket controller, the M2G from Greffen Systems, at two Chicago area multifamily buildings with existing OTR control. Results show that energy savings depend on the degree to which boilers are oversized for their load, represented by cycling rates. Also, savings vary over the heating season with cycling rates, with greater savings observed in shoulder months. Over the monitoring period, oversized boilers at one site showed reductions in cycling and energy consumption in line with prior laboratory studies, while less oversized boilers at another site showed muted savings.« less

  12. Corrosivities in a pilot-scale combustor of a British and two Illinois coals with varying chlorine contents

    USGS Publications Warehouse

    Chou, I.-Ming; Lytle, J.M.; Kung, S.C.; Ho, K.K.

    2000-01-01

    Many US boiler manufacturers have recommended limits on the chlorine (Cl) content (< 0.25% or < 0.3%) of coals to be used in their boilers. These limits were based primarily on extrapolation of British coal data to predict the probable corrosion behavior of US coals. Even though Cl-related boiler corrosion has not been reported by US utilities burning high-Cl Illinois coals, the manufacturer's limits affect the marketability of high-Cl Illinois coals. This study measured the relative rates of corrosion caused by two high-Cl coals (British and Illinois) and one low-Cl Illinois baseline coal under identical pilot-scale combustion conditions for about 1000 h which gave reliable comparisons. Temperatures used reflected conditions in boiler superheaters. The corrosion probes were fabricated from commercial alloy 304SS frequently used at the hottest superheater section of utility boilers. The results showed no evidence of direct correlation between the coal chlorine content and rate of corrosion. A correlation between the rate of corrosion and the metal temperature was obvious. The results suggested that the different field histories of corrosivity from burning high-Cl Illinois coal and high-Cl British coal occurred because of different metal temperatures operated in US and UK utility boilers. The results of this study can be combined into a database, which could be used for lifting the limits on chlorine contents of coals burned in utility boilers in the US.

  13. 46 CFR 52.25-7 - Electric boilers (modifies PEB-1 through PEB-19).

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... ENGINEERING POWER BOILERS Other Boiler Types § 52.25-7 Electric boilers (modifies PEB-1 through PEB-19). Electric boilers required to comply with this part must meet the applicable provisions in this part and the... 46 Shipping 2 2011-10-01 2011-10-01 false Electric boilers (modifies PEB-1 through PEB-19). 52.25...

  14. 46 CFR 52.25-7 - Electric boilers (modifies PEB-1 through PEB-19).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... ENGINEERING POWER BOILERS Other Boiler Types § 52.25-7 Electric boilers (modifies PEB-1 through PEB-19). Electric boilers required to comply with this part must meet the applicable provisions in this part and the... 46 Shipping 2 2010-10-01 2010-10-01 false Electric boilers (modifies PEB-1 through PEB-19). 52.25...

  15. 46 CFR 52.25-7 - Electric boilers (modifies PEB-1 through PEB-19).

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... ENGINEERING POWER BOILERS Other Boiler Types § 52.25-7 Electric boilers (modifies PEB-1 through PEB-19). Electric boilers required to comply with this part must meet the applicable provisions in this part and the... 46 Shipping 2 2012-10-01 2012-10-01 false Electric boilers (modifies PEB-1 through PEB-19). 52.25...

  16. 46 CFR 52.25-7 - Electric boilers (modifies PEB-1 through PEB-19).

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... ENGINEERING POWER BOILERS Other Boiler Types § 52.25-7 Electric boilers (modifies PEB-1 through PEB-19). Electric boilers required to comply with this part must meet the applicable provisions in this part and the... 46 Shipping 2 2014-10-01 2014-10-01 false Electric boilers (modifies PEB-1 through PEB-19). 52.25...

  17. 46 CFR 52.25-7 - Electric boilers (modifies PEB-1 through PEB-19).

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... ENGINEERING POWER BOILERS Other Boiler Types § 52.25-7 Electric boilers (modifies PEB-1 through PEB-19). Electric boilers required to comply with this part must meet the applicable provisions in this part and the... 46 Shipping 2 2013-10-01 2013-10-01 false Electric boilers (modifies PEB-1 through PEB-19). 52.25...

  18. 46 CFR 52.25-5 - Miniature boilers (modifies PMB-1 through PMB-21).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Miniature boilers (modifies PMB-1 through PMB-21). 52.25-5 Section 52.25-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Other Boiler Types § 52.25-5 Miniature boilers (modifies PMB-1 through PMB-21). Miniature boilers must meet the applicable...

  19. 46 CFR 52.25-5 - Miniature boilers (modifies PMB-1 through PMB-21).

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false Miniature boilers (modifies PMB-1 through PMB-21). 52.25-5 Section 52.25-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Other Boiler Types § 52.25-5 Miniature boilers (modifies PMB-1 through PMB-21). Miniature boilers must meet the applicable...

  20. 46 CFR 52.25-5 - Miniature boilers (modifies PMB-1 through PMB-21).

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Miniature boilers (modifies PMB-1 through PMB-21). 52.25-5 Section 52.25-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Other Boiler Types § 52.25-5 Miniature boilers (modifies PMB-1 through PMB-21). Miniature boilers must meet the applicable...

  1. 46 CFR 52.25-5 - Miniature boilers (modifies PMB-1 through PMB-21).

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Miniature boilers (modifies PMB-1 through PMB-21). 52.25-5 Section 52.25-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Other Boiler Types § 52.25-5 Miniature boilers (modifies PMB-1 through PMB-21). Miniature boilers must meet the applicable...

  2. 46 CFR 52.25-5 - Miniature boilers (modifies PMB-1 through PMB-21).

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 2 2013-10-01 2013-10-01 false Miniature boilers (modifies PMB-1 through PMB-21). 52.25-5 Section 52.25-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Other Boiler Types § 52.25-5 Miniature boilers (modifies PMB-1 through PMB-21). Miniature boilers must meet the applicable...

  3. Method and apparatus for capturing carbon dioxide during combustion of carbon containing fuel

    DOEpatents

    Axelbaum, Richard L.; Kumfer, Benjamin M.; Xia, Fei; Gopan, Akshay; Dhungel, Bhupesh

    2018-04-10

    A boiler system having a series of boilers. Each boiler includes a shell having an upstream end, a downstream end, and a hollow interior. The boilers also have an oxidizer inlet entering the hollow interior adjacent the upstream end of the shell and a fuel nozzle positioned adjacent the upstream end of the shell for introducing fuel into the hollow interior of the shell. Each boiler includes a flue duct connected to the shell adjacent the downstream end for transporting flue gas from the hollow interior. Oxygen is delivered to the oxidizer inlet of the first boiler in the series. Flue gas from the immediately preceding boiler in the series is delivered through the oxidizer inlet of each boiler subsequent to the first boiler in the series.

  4. Retrofitted coal-fired firetube boiler and method employed therewith

    DOEpatents

    Wagoner, Charles L.; Foote, John P.

    1995-01-01

    A coal-fired firetube boiler and a method for converting a gas-fired firetube boiler to a coal-fired firetube boiler, the converted boiler including a plurality of combustion zones within the firetube and controlled stoichiometry within the combustion zones.

  5. Development of a Novel Gas Pressurized Stripping Process-Based Technology for CO₂ Capture from Post-Combustion Flue Gases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Shiaoguo

    A novel Gas Pressurized Stripping (GPS) post-combustion carbon capture (PCC) process has been developed by Carbon Capture Scientific, LLC, CONSOL Energy Inc., Nexant Inc., and Western Kentucky University in this bench-scale project. The GPS-based process presents a unique approach that uses a gas pressurized technology for CO₂ stripping at an elevated pressure to overcome the energy use and other disadvantages associated with the benchmark monoethanolamine (MEA) process. The project was aimed at performing laboratory- and bench-scale experiments to prove its technical feasibility and generate process engineering and scale-up data, and conducting a techno-economic analysis (TEA) to demonstrate its energy usemore » and cost competitiveness over the MEA process. To meet project goals and objectives, a combination of experimental work, process simulation, and technical and economic analysis studies were applied. The project conducted individual unit lab-scale tests for major process components, including a first absorption column, a GPS column, a second absorption column, and a flasher. Computer simulations were carried out to study the GPS column behavior under different operating conditions, to optimize the column design and operation, and to optimize the GPS process for an existing and a new power plant. The vapor-liquid equilibrium data under high loading and high temperature for the selected amines were also measured. The thermal and oxidative stability of the selected solvents were also tested experimentally and presented. A bench-scale column-based unit capable of achieving at least 90% CO₂ capture from a nominal 500 SLPM coal-derived flue gas slipstream was designed and built. This integrated, continuous, skid-mounted GPS system was tested using real flue gas from a coal-fired boiler at the National Carbon Capture Center (NCCC). The technical challenges of the GPS technology in stability, corrosion, and foaming of selected solvents, and environmental, health and safety risks have been addressed through experimental tests, consultation with vendors and engineering analysis. Multiple rounds of TEA were performed to improve the GPS-based PCC process design and operation, and to compare the energy use and cost performance of a nominal 550-MWe supercritical pulverized coal (PC) plant among the DOE/NETL report Case 11 (the PC plant without CO₂ capture), the DOE/NETL report Case 12 (the PC plant with benchmark MEA-based PCC), and the PC plant using GPS-based PCC. The results reveal that the net power produced in the PC plant with GPS-based PCC is 647 MWe, greater than that of the Case 12 (550 MWe). The 20-year LCOE for the PC plant with GPS-based PCC is 97.4 mills/kWh, or 152% of that of the Case 11, which is also 23% less than that of the Case 12. These results demonstrate that the GPS-based PCC process is energy-efficient and cost-effective compared with the benchmark MEA process.« less

  6. Mass spectra features of biomass burning boiler and coal burning boiler emitted particles by single particle aerosol mass spectrometer.

    PubMed

    Xu, Jiao; Li, Mei; Shi, Guoliang; Wang, Haiting; Ma, Xian; Wu, Jianhui; Shi, Xurong; Feng, Yinchang

    2017-11-15

    In this study, single particle mass spectra signatures of both coal burning boiler and biomass burning boiler emitted particles were studied. Particle samples were suspended in clean Resuspension Chamber, and analyzed by ELPI and SPAMS simultaneously. The size distribution of BBB (biomass burning boiler sample) and CBB (coal burning boiler sample) are different, as BBB peaks at smaller size, and CBB peaks at larger size. Mass spectra signatures of two samples were studied by analyzing the average mass spectrum of each particle cluster extracted by ART-2a in different size ranges. In conclusion, BBB sample mostly consists of OC and EC containing particles, and a small fraction of K-rich particles in the size range of 0.2-0.5μm. In 0.5-1.0μm, BBB sample consists of EC, OC, K-rich and Al_Silicate containing particles; CBB sample consists of EC, ECOC containing particles, while Al_Silicate (including Al_Ca_Ti_Silicate, Al_Ti_Silicate, Al_Silicate) containing particles got higher fractions as size increase. The similarity of single particle mass spectrum signatures between two samples were studied by analyzing the dot product, results indicated that part of the single particle mass spectra of two samples in the same size range are similar, which bring challenge to the future source apportionment activity by using single particle aerosol mass spectrometer. Results of this study will provide physicochemical information of important sources which contribute to particle pollution, and will support source apportionment activities. Copyright © 2017. Published by Elsevier B.V.

  7. A coordinated MIMO control design for a power plant using improved sliding mode controller.

    PubMed

    Ataei, Mohammad; Hooshmand, Rahmat-Allah; Samani, Siavash Golmohammadi

    2014-03-01

    For the participation of the steam power plants in regulating the network frequency, boilers and turbines should be co-ordinately controlled in addition to the base load productions. Lack of coordinated control over boiler-turbine may lead to instability; oscillation in producing power and boiler parameters; reduction in the reliability of the unit; and inflicting thermodynamic tension on devices. This paper proposes a boiler-turbine coordinated multivariable control system based on improved sliding mode controller (ISMC). The system controls two main boiler-turbine parameters i.e., the turbine revolution and superheated steam pressure of the boiler output. For this purpose, a comprehensive model of the system including complete and exact description of the subsystems is extracted. The parameters of this model are determined according to our case study that is the 320MW unit of Islam-Abad power plant in Isfahan/Iran. The ISMC method is simulated on the power plant and its performance is compared with the related real PI (proportional-integral) controllers which have been used in this unit. The simulation results show the capability of the proposed controller system in controlling local network frequency and superheated steam pressure in the presence of load variations and disturbances of boiler. © 2013 ISA. Published by Elsevier Ltd. All rights reserved.

  8. Advanced, Low/Zero Emission Boiler Design and Operation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Babcock /Wilcox; Illinois State Geological; Worley Parsons

    2007-06-30

    In partnership with the U.S. Department of Energy's National Energy Technology Laboratory, B&W and Air Liquide are developing and optimizing the oxy-combustion process for retrofitting existing boilers as well as new plants. The main objectives of the project is to: (1) demonstrate the feasibility of the oxy-combustion technology with flue gas recycle in a 5-million Btu/hr coal-fired pilot boiler, (2) measure its performances in terms of emissions and boiler efficiency while selecting the right oxygen injection and flue gas recycle strategies, and (3) perform technical and economic feasibility studies for application of the technology in demonstration and commercial scale boilers.more » This document summarizes the work performed during the period of performance of the project (Oct 2002 to June 2007). Detailed technical results are reported in corresponding topical reports that are attached as an appendix to this report. Task 1 (Site Preparation) has been completed in 2003. The experimental pilot-scale O{sub 2}/CO{sub 2} combustion tests of Task 2 (experimental test performance) has been completed in Q2 2004. Process simulation and cost assessment of Task 3 (Techno-Economic Study) has been completed in Q1 2005. The topical report on Task 3 has been finalized and submitted to DOE in Q3 2005. The calculations of Task 4 (Retrofit Recommendation and Preliminary Design of a New Generation Boiler) has been completed in 2004. In Task 6 (engineering study on retrofit applications), the engineering study on 25MW{sub e} unit has been completed in Q2, 2008 along with the corresponding cost assessment. In Task 7 (evaluation of new oxy-fuel power plants concepts), based on the design basis document prepared in 2005, the design and cost estimate of the Air Separation Units, the boiler islands and the CO{sub 2} compression and trains have been completed, for both super and ultra-supercritical case study. Final report of Task-7 is published by DOE in Oct 2007.« less

  9. Application of 1-hydroxyethylidene-1, 1-diphosphonic acid in boiler water for industrial boilers.

    PubMed

    Zeng, Bin; Li, Mao-Dong; Zhu, Zhi-Ping; Zhao, Jun-Ming; Zhang, Hui

    2013-01-01

    The primary method used for boiler water treatment is the addition of chemicals to industrial boilers to prevent corrosion and scaling. The static scale inhibition method was used to evaluate the scale inhibition performance of 1-hydroxyethylidene-1, 1-diphosphonic acid (HEDP). Autoclave static experiments were used to study the corrosion inhibition properties of the main material for industrial boilers (20# carbon steel) with an HEDP additive in the industrial boiler water medium. The electrochemical behavior of HEDP on carbon steel corrosion control was investigated using electrochemical impedance spectroscopy and Tafel polarization techniques. Experimental results indicate that HEDP can have a good scale inhibition effect when added at a quantity of 5 to 7 mg/L at a test temperature of not more than 100 °C. To achieve a high scale inhibition rate, the HEDP dosage must be increased when the test temperature exceeds 100 °C. Electrochemical and autoclave static experimental results suggest that HEDP has a good corrosion inhibition effect on 20# carbon steel at a concentration of 25 mg/L. HEDP is an excellent water treatment agent.

  10. Quality and generation rate of solid residues in the boiler of a waste-to-energy plant.

    PubMed

    Allegrini, E; Boldrin, A; Jansson, S; Lundtorp, K; Fruergaard Astrup, T

    2014-04-15

    The Danish waste management system relies significantly on waste-to-energy (WtE) plants. The ash produced at the energy recovery section (boiler ash) is classified as hazardous waste, and is commonly mixed with fly ash and air pollution control residues before disposal. In this study, a detailed characterization of boiler ash from a Danish grate-based mass burn type WtE was performed, to evaluate the potential for improving ash management. Samples were collected at 10 different points along the boiler's convective part, and analysed for grain size distribution, content of inorganic elements, polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD and PCDF), and leaching of metals. For all samples, PCDD and PCDF levels were below regulatory limits, while high pH values and leaching of e.g. Cl were critical. No significant differences were found between boiler ash from individual sections of the boiler, in terms of total content and leaching, indicating that separate management of individual ash fractions may not provide significant benefits. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Retrofitted coal-fired firetube boiler and method employed therewith

    DOEpatents

    Wagoner, C.L.; Foote, J.P.

    1995-07-04

    A coal-fired firetube boiler and a method for converting a gas-fired firetube boiler to a coal-fired firetube boiler are disclosed. The converted boiler includes a plurality of combustion zones within the firetube and controlled stoichiometry within the combustion zones. 19 figs.

  12. Characteristics of particulate-bound polycyclic aromatic hydrocarbons emitted from industrial grade biomass boilers.

    PubMed

    Yang, Xiaoyang; Geng, Chunmei; Sun, Xuesong; Yang, Wen; Wang, Xinhua; Chen, Jianhua

    2016-02-01

    Polycyclic aromatic hydrocarbons (PAHs) are carcinogenic or mutagenic and are important toxic pollutants in the flue gas of boilers. Two industrial grade biomass boilers were selected to investigate the characteristics of particulate-bound PAHs: one biomass boiler retro-fitted from an oil boiler (BB1) and one specially designed (BB2) biomass boiler. One coal-fired boiler was also selected for comparison. By using a dilution tunnel system, particulate samples from boilers were collected and 10 PAH species were analyzed by gas chromatography-mass spectrometry (GC-MS). The total emission factors (EFs) of PAHs ranged from 0.0064 to 0.0380 mg/kg, with an average of 0.0225 mg/kg, for the biomass boiler emission samples. The total PAH EFs for the tested coal-fired boiler were 1.8 times lower than the average value of the biomass boilers. The PAH diagnostic ratios for wood pellets and straw pellets were similar. The ratio of indeno(1,2,3-cd)pyrene/[indeno(1,2,3-cd)pyrene+benzo(g,h,i)perylene] for the two biomass boilers was lower than those of the reference data for other burning devices, which can probably be used as an indicator to distinguish the emission of biomass boilers from that of industrial coal-fired boilers and residential stoves. The toxic potential of the emission from wood pellet burning was higher than that from straw pellet burning, however both of them were much lower than residential stove exhausts. Copyright © 2015. Published by Elsevier B.V.

  13. FY95 limited energy study for the area `a` package boiler. Holston Army Ammunition Plant, Kingsport, Tennessee. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1995-11-03

    Holston Army Ammunition Plant (HSAAP) in Holston, Tennessee, manufactures explosives from raw materials. The facility comprises two separate areas designated Area `A11 and Area 11B`. Each area is served by a steam plant which produces steam for production processes, equipment operation, space heating, domestic water heating, steam tracing, and product storage heating requirements. The purpose of this study is to identify and evaluate the technical and economic feasibility of alternative methods of meeting the steam requirements of the Area 11A11 industrial complex. The following items were specifically requested to be evaluated. Evaluate the use of two new gas-fired packaged boilersmore » sized to meet the requirements of the industrial complex. The new boilers would be installed adjacent to the existing steam plant and would utilize the existing smokestacks and steam distribution system. Evaluate using the existing steam distribution system rather than locating multiple boilers at various sites. Existing steam driven chillers will be replaced with electric driven equipment. Evaluate this impact on the steam system requirements. Field survey and test two existing gas-fired packaged boilers located at the Volunteer Army Ammunition Plant in Chattanooga, Tennessee. The two boilers were last used about 1980 and are presently laid away. The boilers are approximately the same capacity and operating characteristics as the ones at HSAAP. Relocation of the existing boilers and ancillary equipment (feedwater pumps, generators, fans, etc.) would be required as well as repairs or modifications necessary to meet current operating conditions and standards.« less

  14. Experience of implementation of in-furnace methods of decreasing NO x in E-320-13.8-560GM boilers: Problems and ways for their solution

    NASA Astrophysics Data System (ADS)

    Tugov, A. N.; Supranov, V. M.; Izyumov, M. A.; Vereshchetin, V. A.; Usman, Yu. M.; Natal'in, A. S.

    2017-12-01

    During natural gas combustion, the content of nitrogen oxides in combustion products is approximately 450 mg/m3 in many E-320-13.8-560GM boilers in service, which is more than 3.5 times higher than the established maximum NO x concentrations in flue gases for such boilers. Estimates according to the existing techniques have shown that gas combustion on the basis of in-furnace techniques (the feeding of combustion products to burners together with air in the volume of 15% and two-stage combustion with 20% air feeding through the nozzles upstream of the burners) enables one to decrease NO x emissions to the level of concentrations of less than 100 mg/m3, which is lower than the maximum allowable values. However, the application of any of the proposed measures with respect to a boiler makes its operation under normal load significantly difficult, since the thermal capacity of the superheater is higher in both cases, which leads to an increase in the temperature of superheated steam above the maximum allowable temperature. On the basis of the developed adapted boiler model, which was created using the Boiler Designer software, we performed numerical studies to determine the required boiler reconstruction volume; the implementation of this reconstruction will provide reliable boiler operation at all working loads and ensure the normative values of NO x emissions. According to the results of thermal calculations, it was proposed to reduce the surface of the cold stage of the superheater circuit and increase the size of the economizer. It is noted that the implementation of environmental protection measures usually decreases the boiler efficiency. At the same time, it has been established that the technical and economic performance of the E-320-13.8-560GM boiler does not decrease owing to an increase in the economizer surface and a decrease in air inflows and overflows in regenerative air heaters and remains at the same level if the air inflow volume decreases from the available 30 to 20%. The fundamental solutions that were used for the E-320-13.8-560GM boiler to decrease NO x emissions can also be used for other BKZ gas-and-oil-fired boilers.

  15. 30 CFR 77.413 - Boilers.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Boilers. 77.413 Section 77.413 Mineral... Mechanical Equipment § 77.413 Boilers. (a) Boilers shall be equipped with guarded, well-maintained water... the gages shall be kept clean and free of scale and rust. (b) Boilers shall be equipped with automatic...

  16. 49 CFR 230.30 - Lap-joint seam boilers.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Lap-joint seam boilers. 230.30 Section 230.30..., DEPARTMENT OF TRANSPORTATION STEAM LOCOMOTIVE INSPECTION AND MAINTENANCE STANDARDS Boilers and Appurtenances Inspection and Repair § 230.30 Lap-joint seam boilers. Every boiler having lap-joint longitudinal seams...

  17. 33. VIEW OF BASEMENT UNDER EAST BOILER ROOM LOOKING TOWARD ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    33. VIEW OF BASEMENT UNDER EAST BOILER ROOM LOOKING TOWARD WEST BOILER ROOM BASEMENT THROUGH THE ASH TRANSFER TUNNEL. ASH HOPPER FOR BOILER 900 IS ON THE RIGHT. NOTE THE TRACKS ALONG THE FLOOR OF THE TUNNEL. A SMALL ELECTRIC LOCOMOTIVE HAULED CARS FOR TRANSFERRING ASH FROM BOILERS TO DISPOSAL SITES OUTSIDE THE BUILDING. THIS SYSTEM BECAME OBSOLETE IN 1938 WHEN BOILERS IN THE WEST BOILER ROOM WERE REMOVED AND PULVERIZED COAL WAS ADOPTED AS THE FUEL. - New York, New Haven & Hartford Railroad, Cos Cob Power Plant, Sound Shore Drive, Greenwich, Fairfield County, CT

  18. Method and system for SCR optimization

    DOEpatents

    Lefebvre, Wesley Curt [Boston, MA; Kohn, Daniel W [Cambridge, MA

    2009-03-10

    Methods and systems are provided for controlling SCR performance in a boiler. The boiler includes one or more generally cross sectional areas. Each cross sectional area can be characterized by one or more profiles of one or more conditions affecting SCR performance and be associated with one or more adjustable desired profiles of the one or more conditions during the operation of the boiler. The performance of the boiler can be characterized by boiler performance parameters. A system in accordance with one or more embodiments of the invention can include a controller input for receiving a performance goal for the boiler corresponding to at least one of the boiler performance parameters and for receiving data values corresponding to boiler control variables and to the boiler performance parameters. The boiler control variables include one or more current profiles of the one or more conditions. The system also includes a system model that relates one or more profiles of the one or more conditions in the boiler to the boiler performance parameters. The system also includes an indirect controller that determines one or more desired profiles of the one or more conditions to satisfy the performance goal for the boiler. The indirect controller uses the system model, the received data values and the received performance goal to determine the one or more desired profiles of the one or more conditions. The system model also includes a controller output that outputs the one or more desired profiles of the one or more conditions.

  19. Tdp studies and tests for C. A. Energia Electrica de Venezuela (enelven) at planta ramon laguna, units RL-17 and RL-10. Volume 2. Unit RL-10 boiler condition assessment report. Export trade information

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1991-03-28

    The study, conducted by Babcock and Wilcox, was funded by the U.S. Trade and Development agency on behalf of Enelven. In order to maximize generated power output and minimize operating costs at Planta Ramon Laguna, tests were done to evaluate the condition of equipment at the plant. In order to identify any damage and determine the operating output of each unit, assessments were done of the furnaces, boilers, generators and boiler feed pumps being used in the plant. The report presents the results of these tests. This is the second of three volumes and it includes the following section: (1)more » Condition Assessment of Unit RL-10 Boiler.« less

  20. Feasible experimental study on the utilization of a 300 MW CFB boiler desulfurizating bottom ash for construction applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lu, X.F.; Amano, R.S.

    2006-12-15

    CFB boiler ash cannot be used as a cement replacement in concrete due to its unacceptably high sulfur content. The disposal in landfills has been the most common means of handling ash in circulating fluidized bed boiler power plants. However for a 300 MW CFB boiler power plant, there will be 600,000 tons of ash discharged per year and will result in great volumes and disposal cost of ash byproduct. It was very necessary to solve the utilization of CFB ash and to decrease the disposal cost of CFB ash. The feasible experimental study results on the utilization of themore » bottom ashes of a 300 MW CFB boiler in Baima power plant in China were reported in this paper. The bottom ashes used for test came from the discharged bottom ashes in a 100 MW CFB boiler in which the anthracite and limestone designed for the 300 MW CFB project was burned. The results of this study showed that the bottom ash could be used for cementitious material, road concrete, and road base material. The masonry cements, road concrete with 30 MPa compressive strength and 4.0 MPa flexural strength, and the road base material used for base courses of the expressway, the main road and the minor lane were all prepared with milled CFB bottom ashes in the lab. The better methods of utilization of the bottom ashes were discussed in this paper.« less

  1. Near-Zero Emissions Oxy-Combustion Flue Gas Purification Task 2: SOx/Nox/Hg Removal for High Sulfur Coal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nick Degenstein; Minish Shah; Doughlas Louie

    2012-05-01

    The goal of this project is to develop a near-zero emissions flue gas purification technology for existing PC (pulverized coal) power plants that are retrofitted with oxy-combustion technology. The objective of Task 2 of this project was to evaluate an alternative method of SOx, NOx and Hg removal from flue gas produced by burning high sulfur coal in oxy-combustion power plants. The goal of the program was not only to investigate a new method of flue gas purification but also to produce useful acid byproduct streams as an alternative to using a traditional FGD and SCR for flue gas processing.more » During the project two main constraints were identified that limit the ability of the process to achieve project goals. 1) Due to boiler island corrosion issues >60% of the sulfur must be removed in the boiler island with the use of an FGD. 2) A suitable method could not be found to remove NOx from the concentrated sulfuric acid product, which limits sale-ability of the acid, as well as the NOx removal efficiency of the process. Given the complexity and safety issues inherent in the cycle it is concluded that the acid product would not be directly saleable and, in this case, other flue gas purification schemes are better suited for SOx/NOx/Hg control when burning high sulfur coal, e.g. this project's Task 3 process or a traditional FGD and SCR.« less

  2. 46 CFR 189.15-1 - Standards in inspection of hulls, boilers, and machinery.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Standards in inspection of hulls, boilers, and machinery... inspection of hulls, boilers, and machinery. In the inspection of hulls, boilers, and machinery of vessels... chapter, respecting material and construction of hulls, boilers, and machinery, and certificate of...

  3. 46 CFR 91.15-1 - Standards in inspection of hulls, boilers, and machinery.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Standards in inspection of hulls, boilers, and machinery... hulls, boilers, and machinery. In the inspection of hulls, boilers, and machinery of vessels, the..., respecting material and inspection of hulls, boilers, and machinery, and the certificate of classification...

  4. 30 CFR 56.13030 - Boilers.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Boilers. 56.13030 Section 56.13030 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Compressed Air and Boilers § 56.13030 Boilers. (a) Fired pressure vessels (boiler...

  5. 30 CFR 56.13030 - Boilers.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Boilers. 56.13030 Section 56.13030 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Compressed Air and Boilers § 56.13030 Boilers. (a) Fired pressure vessels (boiler...

  6. 30 CFR 56.13030 - Boilers.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Boilers. 56.13030 Section 56.13030 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Compressed Air and Boilers § 56.13030 Boilers. (a) Fired pressure vessels (boiler...

  7. 40 CFR 63.7499 - What are the subcategories of boilers and process heaters?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 13 2010-07-01 2010-07-01 false What are the subcategories of boilers..., and Institutional Boilers and Process Heaters Emission Limits and Work Practice Standards § 63.7499 What are the subcategories of boilers and process heaters? The subcategories of boilers and process...

  8. Efficiency assessment of bi-radiated screens and improved convective set of tubes during the modernization of PTVM-100 tower hot-water boiler based on controlled all-mode mathematic models of boilers on Boiler Designer software

    NASA Astrophysics Data System (ADS)

    Orumbayev, R. K.; Kibarin, A. A.; Khodanova, T. V.; Korobkov, M. S.

    2018-03-01

    This work contains analysis of technical values of tower hot-water boiler PTVM-100 when operating on gas and oil residual. After the test it became clear that due to the construction deficiency during the combustion of oil residual, it is not possible to provide long-term production of heat. There is also given a short review on modernization of PTVM-100 hot-water boilers. With the help of calculations based on controlled all-mode mathematic modules of hot-water boilers in BOILER DESIGNER software, it was shown that boiler modernization by use of bi-radiated screens and new convective set of tubes allows decreasing sufficiently the temperature of combustor output gases and increase reliability of boiler operation. Constructive changes of boiler unit suggested by authors of this work, along with increase of boiler’s operation reliability also allow to improve it’s heat production rates and efficiency rate up to 90,5% when operating on fuel oil and outdoor installation option.

  9. Control Techtronics International

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    West, J.

    1995-12-31

    Polish graded coal can be burned in existing stoker boilers and meet the 1998 Air Quality standard. This is accomplished with the Control Techtronics microprocessor-based combustion controller accurately and repeatedly: (a) matching the combustion air to the coal firing rate, with continuous stack sensor feedback; (b) continuously varying the boiler`s firing rate based on output water temperature or steam pressure; (c) continuously varying the exhaust fan`s speed to maintain minimum negative pressure in the boiler`s combustion chamber; and recirculating a portion of the flue gas, at varying amounts throughout the boiler`s firing rate. Systems for five boilers have been installedmore » and are operating on MPEC`s Balicka plant in Krakow. Control Techtronics International has $10 million of U.S. Export-Import Bank funds available for similar projects throughout Poland.« less

  10. Economic Analysis of Coal-Fired Cogeneration Plants for Air Force Bases

    DTIC Science & Technology

    1990-10-01

    control . However, the existing stoker boilers at Griffiss AFB use lime scrubbers for flue gas desulfurization . The following input parameters were used to...boiler plant was newly installed in 1985 and is in excellent condition. Spray dryer scrubbers are used for flue gas desulfurization . 32 5.3.2 Heating Fuel...for stoker boilers in the previous heating plant studies, 1 ,3 and for sites that require flue gas desulfurization , an efficiency of 80% was used

  11. Lauryl Amine as heavy metal collector of boiler ash from pulp and paper mill waste

    NASA Astrophysics Data System (ADS)

    Sembiring, M. P.; Kaban, J.; Bangun, N.; Saputra, E.

    2018-04-01

    Theincreasing of demand of pulp and paper products, will following with the growing the pulp and paper industryand generate significant mill waste. The total waste reached 1/3 of the amount raw materials used and ash boiler is the waste with the largest percentage of 52%. For that it takes effort to manage the existing waste. The boiler ash contained the chemical elements, it can be utilized such as fertilizer, because it also contains transition metals in form of heavy metal such as Cadmium (Cd), Cobalt (Co), Chrome (Cr), Cupprum (Cu), Ferrum (Fe), Nickel (Ni), and Zinc (Zn), the use of boiler ash must follow the threshold specified by the Government. Several studies have been undertaken to reduce and extract heavy metals from ash and sand of the boiler by using carbon dioxide as its ligand. Eelectrochemical method was used to remove and recovery of heavy metals from the incenerator. This study focused on removal of heavy metals using Lauryl Amine as collector and three solvents namely Dichloromethane, Ethanol and n-Hexane. The treatmentswas able to extract the heavy metal and generally reduce the heavy metal content of ash boiler pulp and paper mill waste. The combination treatment used toreduce the heavy metal content of 5 gram Lauryl Amine collector in Dichloromethane solvent for 4 hours process time.

  12. CHP as a Boiler Replacement Opportunity (Webinar) – April 30, 2013

    EPA Pesticide Factsheets

    This webinar provides information about the benefits of replacing a boiler with a CHP system, describes CHP project analysis and delivery processes, and highlights a case study at Penn State University.

  13. Model-free adaptive control of supercritical circulating fluidized-bed boilers

    DOEpatents

    Cheng, George Shu-Xing; Mulkey, Steven L

    2014-12-16

    A novel 3-Input-3-Output (3.times.3) Fuel-Air Ratio Model-Free Adaptive (MFA) controller is introduced, which can effectively control key process variables including Bed Temperature, Excess O2, and Furnace Negative Pressure of combustion processes of advanced boilers. A novel 7-input-7-output (7.times.7) MFA control system is also described for controlling a combined 3-Input-3-Output (3.times.3) process of Boiler-Turbine-Generator (BTG) units and a 5.times.5 CFB combustion process of advanced boilers. Those boilers include Circulating Fluidized-Bed (CFB) Boilers and Once-Through Supercritical Circulating Fluidized-Bed (OTSC CFB) Boilers.

  14. Basic design studies for a 600 MWe CFB boiler (270b, 2 x 600 C)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bursi, J.M.; Lafanechere, L.; Jestin, L.

    Commercial CFB boilers are currently available in the 300 MWe equivalent range for use with international coal. Retrofitting of Provence 4 with a 250 MWe CFB boiler was an important step in CFB development. In light of the results obtained from two large French units--Emile Huchet 4 (125 MWe) and Provence 4 (250 MWe)--this paper focuses on the main technical points which are currently being studied in relation to the basic design of a 600 MWe CFB boiler, a project that has been undertaken by EDF. The general aim of this project is to demonstrate the competitiveness of a CFBmore » boiler compared with a PF boiler. The main areas of focus in the design of this large CFB boiler with advanced steam conditions are described. These points are subjected to particular analysis from a design standpoint. The objective is to prepare the precise specifications needed to ensure a product which is optimized in terms of quality/cost or service/cost. Due to the present lack of theoretical understanding of the refined and complex two-phase flow, design is a challenge which has to be based on reliable and comprehensive data obtained from large plants in commercial operation. This will ensure that the advantages of CFB which arise from the hydrodynamics within the circulation loop are maintained. The major goals of maintaining good particle residence time and concentration in the furnace are described. Misunderstanding of CFB furnace bottom conditions is also pointed out, with cost reduction and better NO{sub x} capture certainly among the major new targets in relation to bottom furnace design. General problems associated with the heat exchanger arrangement, principally those linked to high steam conditions and, especially, the vaporization system, are discussed. Once again, comparison with PF in this area showed that CFB boilers appear more competitive. Finally, the main area in which there is a need for sharing of CFB experience among CFB users is pointed out.« less

  15. Startup, Commissioning and Operation of Fenyi 100MW CFB Boiler

    NASA Astrophysics Data System (ADS)

    Wang, Zhiwei; Yu, Wugao; Bo, Shi

    The first 100MW CFB boiler, designed by the Thermal Power Research Institute and manufactured by Harbin Boiler Company Limited, has been successfully running in Jiangxi Fenyi Power Plant since 2003. Local high ash content anthracite and lean coal that are very difficult to burn out are used in the 100 MW CFB boiler. The results of the 100MW CFB boiler shows that the CFB boiler can run in 30% MCR and startup with two under bed burners, and the boiler efficiency higher than 88% can be got after the combustion modification test. The CFB boiler can be operated with full load and reaches design parameters. The emissions of NO, N2O and CO are less than 7Omg/m3, 30mg/m3, and 125mg/m3, respectively, and SO2 less than 400mg/m3 after limestone injection. The bottom ash temperature from bed ash coolers is less than 120°C after its modification. Coal blockage at the coal storage silo is the main problem influencing the CFB boiler continuous operation. The running experiences for 5 years proved that the CFB boiler performance is successful, and the results were applied in 210 MW and 330 MW CFB Boiler design of Fenyi Power Plant.

  16. 46 CFR 52.20-17 - Opening between boiler and safety valve (modifies PFT-44).

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Opening between boiler and safety valve (modifies PFT-44). 52.20-17 Section 52.20-17 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Requirements for Firetube Boilers § 52.20-17 Opening between boiler and safety valve...

  17. 46 CFR 52.20-17 - Opening between boiler and safety valve (modifies PFT-44).

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false Opening between boiler and safety valve (modifies PFT-44). 52.20-17 Section 52.20-17 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Requirements for Firetube Boilers § 52.20-17 Opening between boiler and safety valve...

  18. 46 CFR 52.20-17 - Opening between boiler and safety valve (modifies PFT-44).

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 2 2013-10-01 2013-10-01 false Opening between boiler and safety valve (modifies PFT-44). 52.20-17 Section 52.20-17 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Requirements for Firetube Boilers § 52.20-17 Opening between boiler and safety valve...

  19. 46 CFR 52.20-17 - Opening between boiler and safety valve (modifies PFT-44).

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Opening between boiler and safety valve (modifies PFT-44). 52.20-17 Section 52.20-17 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Requirements for Firetube Boilers § 52.20-17 Opening between boiler and safety valve...

  20. Drying Milk With Boiler Exhaust

    NASA Technical Reports Server (NTRS)

    Broussard, M. R.

    1984-01-01

    Considerable energy saved in powdered-milk industry. Only special requirement boiler fired with natural gas or other clean fuel. Boiler flue gas fed to spray drier where it directly contacts product to be dried. Additional heat supplied by auxillary combustor when boiler output is low. Approach adaptable to existing plants with minimal investment because most already equipped with natural-gas-fired boilers.

  1. 46 CFR 52.20-17 - Opening between boiler and safety valve (modifies PFT-44).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Opening between boiler and safety valve (modifies PFT-44). 52.20-17 Section 52.20-17 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Requirements for Firetube Boilers § 52.20-17 Opening between boiler and safety valve...

  2. 21 CFR 173.310 - Boiler water additives.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 3 2014-04-01 2014-04-01 false Boiler water additives. 173.310 Section 173.310... Boiler water additives. Boiler water additives may be safely used in the preparation of steam that will... Total not to exceed 1.5 parts per million in boiler feed water. Copolymer contains not more than 0.5...

  3. 40 CFR 76.2 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... combustion of fossil fuel in a utility boiler. Group 1 boiler means a tangentially fired boiler or a dry... (boiler information) of the Department of Energy's Form EIA-767 for 1995. Non-plug-in combustion controls...

  4. 40 CFR 76.2 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... combustion of fossil fuel in a utility boiler. Group 1 boiler means a tangentially fired boiler or a dry... (boiler information) of the Department of Energy's Form EIA-767 for 1995. Non-plug-in combustion controls...

  5. 40 CFR 76.2 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... combustion of fossil fuel in a utility boiler. Group 1 boiler means a tangentially fired boiler or a dry... (boiler information) of the Department of Energy's Form EIA-767 for 1995. Non-plug-in combustion controls...

  6. 40 CFR 76.2 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... combustion of fossil fuel in a utility boiler. Group 1 boiler means a tangentially fired boiler or a dry... (boiler information) of the Department of Energy's Form EIA-767 for 1995. Non-plug-in combustion controls...

  7. 40 CFR 76.2 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... combustion of fossil fuel in a utility boiler. Group 1 boiler means a tangentially fired boiler or a dry... (boiler information) of the Department of Energy's Form EIA-767 for 1995. Non-plug-in combustion controls...

  8. Novel CFB Boiler Technology with Reconstruction of its Fluidization State

    NASA Astrophysics Data System (ADS)

    Yang, H. R.; Zhang, H.; Lu, J. F.; Lfu, Q.; Wu, Y. X.; Yuet, G. X.; Su, J.; Fu, Z. P.

    Compared with a conventional pulverized coal fired boiler, the combustion efficiency of a CFB boiler is lower while the self-consumed service power is 1-2% higher. The solution of these problems is the key research topic for researchers and manufacturers of CFB boilers. Based on the State Specification Design Theory of CFB boilers, Tsinghua University proposed a novel CFB technology by reconstruction of the fluidization state in the furnace by adjusting the bed inventory and bed quality. Theoretical analyses show that there is an optimal bed pressure drop, around which the boiler operation can achieve the maximal combustion efficiency and with significant reduction of the wear of the heating surface and fan power consumption. The proposed novel process was implemented in a 75t/h CFB boiler. The results of field tests on this boiler validated the theoretical analyses.

  9. Small boiler uses waste coal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Virr, M.J.

    Burning coal waste in small boilers at low emissions poses considerable problem. While larger boiler suppliers have successfully installed designs in the 40 to 80 MW range for some years, the author has been developing small automated fluid bed boiler plants for 25 years that can be applied in the range of 10,000 to 140,000 lbs/hr of steam. Development has centered on the use of an internally circulating fluid bed (CFB) boiler, which will burn waste fuels of most types. The boiler is based on the traditional D-shaped watertable boiler, with a new type of combustion chamber that enables amore » three-to-one turndown to be achieved. The boilers have all the advantages of low emissions of the large fluid boilers while offering a much lower height incorporated into the package boiler concept. Recent tests with a waste coal that had a high nitrogen content of 1.45% demonstrated a NOx emission below the federal limit of 0.6 lbs/mm Btu. Thus a NOx reduction on the order of 85% can be demonstrate by combustion modification alone. Further reductions can be made by using a selective non-catalytic reduction (SNCR) system and sulfur absorption of up to 90% retention is possible. The article describes the operation of a 30,000 lbs/hr boiler at the Fayette Thermal LLC plant. Spinheat has installed three ICFB boilers at a nursing home and a prison, which has been tested on poor-grade anthracite and bituminous coal. 2 figs.« less

  10. High Temperature Behavior of Cr3C2-NiCr Coatings in the Actual Coal-Fired Boiler Environment

    NASA Astrophysics Data System (ADS)

    Bhatia, Rakesh; Sidhu, Hazoor Singh; Sidhu, Buta Singh

    2015-03-01

    Erosion-corrosion is a serious problem observed in steam-powered electricity generation plants, and industrial waste incinerators. In the present study, four compositions of Cr3C2-(Ni-20Cr) alloy coating powder were deposited by high-velocity oxy-fuel spray technique on T-91 boiler tube steel. The cyclic studies were performed in a coal-fired boiler at 1123 K ± 10 K (850 °C ± 10 °C). X-ray diffraction, scanning electron microscopy/energy dispersive X-ray analysis and elemental mapping analysis techniques were used to analyze the corrosion products. All the coatings deposited on T-91 boiler tube steel imparted hot corrosion resistance. The 65 pctCr3C2 -35 pct (Ni-20Cr)-coated T-91 steel sample performed better than all other coated samples in the given environment.

  11. Time-resolved analysis of primary volatile emissions and secondary aerosol formation potential from a small-scale pellet boiler

    NASA Astrophysics Data System (ADS)

    Czech, Hendryk; Pieber, Simone M.; Tiitta, Petri; Sippula, Olli; Kortelainen, Miika; Lamberg, Heikki; Grigonyte, Julija; Streibel, Thorsten; Prévôt, André S. H.; Jokiniemi, Jorma; Zimmermann, Ralf

    2017-06-01

    Small-scale pellet boilers and stoves became popular as a wood combustion appliance for domestic heating in Europe, North America and Asia due to economic and environmental aspects. Therefore, an increasing contribution of pellet boilers to air pollution is expected despite their general high combustion efficiency. As emissions of primary organic aerosol (POA) and permanent gases of pellet boilers are well investigated, the scope of this study was to investigate the volatile organic emissions and the formation potential of secondary aerosols for this type of appliance. Fresh and aged emissions were analysed by a soot-particle aerosol time-of-flight mass spectrometry (SP-AMS) and the molecular composition of the volatile precursors with single-photon ionisation time-of-flight mass spectrometry (SPI-TOFMS) at different pellet boiler operation conditions. Organic emissions in the gas phase were dominated by unsaturated hydrocarbons while wood-specific VOCs, e.g. phenolic species or substituted furans, were only detected during the starting phase. Furthermore, organic emissions in the gas phase were found to correlate with fuel grade and combustion technology in terms of secondary air supply. Secondary organic aerosols of optimised pellet boiler conditions (OPT, state-of-the-art combustion appliance) and reduced secondary air supply (RSA, used as a proxy for pellet boilers of older type) were studied by simulating atmospheric ageing in a Potential Aerosol Mass (PAM) flow reactor. Different increases in OA mass (55% for OPT, 102% for RSA), associated with higher average carbon oxidation state and O:C, could be observed in a PAM chamber experiment. Finally, it was found that derived SOA yields and emission factors were distinctly lower than reported for log wood stoves.

  12. Size fractionation of waste-to-energy boiler ash enables separation of a coarse fraction with low dioxin concentrations.

    PubMed

    Weidemann, E; Allegrini, E; Fruergaard Astrup, T; Hulgaard, T; Riber, C; Jansson, S

    2016-03-01

    Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/F) formed in modern Waste-to-Energy plants are primarily found in the generated ashes and air pollution control residues, which are usually disposed of as hazardous waste. The objective of this study was to explore the occurrence of PCDD/F in different grain size fractions in the boiler ash, i.e. ash originating from the convection pass of the boiler. If a correlation between particle size and dioxin concentrations could be found, size fractionation of the ashes could reduce the total amount of hazardous waste. Boiler ash samples from ten sections of a boiler's convective part were collected over three sampling days, sieved into three different size fractions - <0.09 mm, 0.09-0.355 mm, and >0.355 mm - and analysed for PCDD/F. The coarse fraction (>0.355 mm) in the first sections of the horizontal convection pass appeared to be of low toxicity with respect to dioxin content. While the total mass of the coarse fraction in this boiler was relatively small, sieving could reduce the amount of ash containing toxic PCDD/F by around 0.5 kg per tonne input waste or around 15% of the collected boiler ash from the convection pass. The mid-size fraction in this study covered a wide size range (0.09-0.355 mm) and possibly a low toxicity fraction could be identified by splitting this fraction into more narrow size ranges. The ashes exhibited uniform PCDD/F homologue patterns which suggests a stable and continuous generation of PCDD/F. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Fire-tube boiler optimization criteria and efficiency indicators rational values defining

    NASA Astrophysics Data System (ADS)

    Batrakov, P. A.; Mikhailov, A. G.; Ignatov, V. Yu

    2018-01-01

    Technical and economic calculations problems solving with the aim of identifying the opportunity to recommend the project for industrial implementation are represented in the paper. One of the main determining factors impacting boiler energy efficiency is the exhaust gases temperature, as well as the furnace volume thermal stress. Fire-tube boilers with different types of furnaces are considered in the study. The fullest analysis of the boiler performance thermal and technical indicators for the following engineering problem: Q=idem, M=idem and evaluation according to η, B is presented. The furnace with the finned ellipse profile application results in the fuel consumption decrease due to a more efficient heat exchange surface of the furnace compared to other examined ones.

  14. 40 CFR 63.7491 - Are any boilers or process heaters not subject to this subpart?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 13 2010-07-01 2010-07-01 false Are any boilers or process heaters not..., and Institutional Boilers and Process Heaters What This Subpart Covers § 63.7491 Are any boilers or process heaters not subject to this subpart? The types of boilers and process heaters listed in paragraphs...

  15. 46 CFR 61.05-5 - Preparation of boilers for inspection and test.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Preparation of boilers for inspection and test. 61.05-5... PERIODIC TESTS AND INSPECTIONS Tests and Inspections of Boilers § 61.05-5 Preparation of boilers for... preparing the boilers for the hydrostatic test, they shall be filled with water at not less than 70 °F. and...

  16. Analysis on effects of energy efficiency regulations & standards for industrial boilers in China

    NASA Astrophysics Data System (ADS)

    Liu, Ren; Chen, Lili; Zhao, Yuejin; Liu, Meng

    2017-11-01

    The industrial boilers in China are featured by large quantity, wide distribution, high energy consumption and heavy environmental pollution, which are key problems faced by energy conservation and environmental protection in China. Meanwhile, industrial boilers are important equipment for national economy and people’s daily life, and energy conservation gets through all segments from type selection, purchase, installation and acceptance to fuel management, operation, maintenance and service. China began to implement such national mandatory standards and regulations for industrial boiler as GB24500-2009 The Minimum Allowable Values of Energy Efficiency and Energy Efficiency Grades of Industrial Boilers and TSG G002-2010 Supervision Regulation on Energy-Saving Technology for Boilers since 2009, which obviously promote the development of energy conservation of industrial boilers, but there are also some problems with the rapid development of technologies for energy conservation of industrial boilers. In this paper, the implementation of energy efficiency standards for industrial boilers in China and the significance are analyzed based on survey data, and some suggestions are proposed for the energy efficiency standards for industrial boilers. Support by Project 2015424050 of Special Fund for quality control Research in the Public Interest

  17. Status and Analysis on Effects of Energy Efficiency Standards for Industrial Boilers in China

    NASA Astrophysics Data System (ADS)

    Liu, Ren; Chen, Lili; Liu, Meng; Ding, Qing; Zhao, Yuejin

    2017-11-01

    Energy conservation and environmental protection is the basic policy of China, and is an important part of ecological civilization construction. The industrial boilers in China are featured by large quantity, wide distribution, high energy consumption and heavy environmental pollution, which are key problems faced by energy conservation and environmental protection in China. Meanwhile, industrial boilers are important equipment for national economy and people’s daily life, and energy conservation gets through all segments from type selection, purchase, installation and acceptance to fuel management, operation, maintenance and service. China began to implement such national mandatory standards and regulations for industrial boiler as GB24500-2009 The Minimum Allowable Values of Energy Efficiency and Energy Efficiency Grades of Industrial Boilers and TSG G002-2010 Supervision Regulation on Energy-Saving Technology for Boilers since 2009, which obviously promote the development of energy conservation of industrial boilers, but there are also some problems with the rapid development of technologies for energy conservation of industrial boilers. In this paper, the implementation of energy efficiency standards for industrial boilers in China and the significance are analyzed based on survey data, and some suggestions are proposed for the energy efficiency standards for industrial boilers.

  18. Study on key technologies of optimization of big data for thermal power plant performance

    NASA Astrophysics Data System (ADS)

    Mao, Mingyang; Xiao, Hong

    2018-06-01

    Thermal power generation accounts for 70% of China's power generation, the pollutants accounted for 40% of the same kind of emissions, thermal power efficiency optimization needs to monitor and understand the whole process of coal combustion and pollutant migration, power system performance data show explosive growth trend, The purpose is to study the integration of numerical simulation of big data technology, the development of thermal power plant efficiency data optimization platform and nitrogen oxide emission reduction system for the thermal power plant to improve efficiency, energy saving and emission reduction to provide reliable technical support. The method is big data technology represented by "multi-source heterogeneous data integration", "large data distributed storage" and "high-performance real-time and off-line computing", can greatly enhance the energy consumption capacity of thermal power plants and the level of intelligent decision-making, and then use the data mining algorithm to establish the boiler combustion mathematical model, mining power plant boiler efficiency data, combined with numerical simulation technology to find the boiler combustion and pollutant generation rules and combustion parameters of boiler combustion and pollutant generation Influence. The result is to optimize the boiler combustion parameters, which can achieve energy saving.

  19. 42. BOILER HOUSE FOURTH FLOOR, FORCED DRAFT FANS ABOVE BOILERS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    42. BOILER HOUSE FOURTH FLOOR, FORCED DRAFT FANS ABOVE BOILERS (SEE DRAWING Nos. 10 & 11 OF 13) - Delaware County Electric Company, Chester Station, Delaware River at South end of Ward Street, Chester, Delaware County, PA

  20. The Technology Introduction of Chain Boiler Energy Conservation Transformation

    NASA Astrophysics Data System (ADS)

    Li, Henan; Liu, Xiwen; Yuan, Hong; Lin, Jiadai; Zhang, Yu

    2017-12-01

    Introduced the present status of chain boiler efficiency is low, the system analysis of the chain boiler optimization and upgrading of technology, for the whole progress of chain boiler to provide some ideas and reference.

  1. 2. VIEW SOUTHWESTNORTH ELEVATION OF BOILER SHOP SECTION OF THE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. VIEW SOUTHWEST-NORTH ELEVATION OF BOILER SHOP SECTION OF THE BETHLEHEM STEEL COMPANY SHIPYARD BLACKSMITH SHOP/BOILER SHOP. - Bethlehem Steel Company Shipyard, Blacksmith Shop-Boiler Shop, 1201-1321 Hudson Street, Hoboken, Hudson County, NJ

  2. 6. VIEW WESTINTERIOR OF BOILER SHOP SECTION OF THE BETHLEHEM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. VIEW WEST-INTERIOR OF BOILER SHOP SECTION OF THE BETHLEHEM STEEL COMPANY SHIPYARD BLACKSMITH SHOP/BOILER SHOP. - Bethlehem Steel Company Shipyard, Blacksmith Shop-Boiler Shop, 1201-1321 Hudson Street, Hoboken, Hudson County, NJ

  3. 7. VIEW EASTINTERIOR OF BOILER SHOP SECTION OF THE BETHLEHEM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. VIEW EAST-INTERIOR OF BOILER SHOP SECTION OF THE BETHLEHEM STEEL COMPANY SHIPYARD BLACKSMITH SHOP/BOILER SHOP. - Bethlehem Steel Company Shipyard, Blacksmith Shop-Boiler Shop, 1201-1321 Hudson Street, Hoboken, Hudson County, NJ

  4. Cogeneration Technology Alternatives Study (CTAS). Volume 6: Computer data. Part 2: Residual-fired nocogeneration process boiler

    NASA Technical Reports Server (NTRS)

    Knightly, W. F.

    1980-01-01

    Computer generated data on the performance of the cogeneration energy conversion system are presented. Performance parameters included fuel consumption and savings, capital costs, economics, and emissions of residual fired process boilers.

  5. Operator's Manual, Boiler Room Operations and Maintenance. Supplement A, Air Pollution Training Institute Self-Instructional Course SI-466.

    ERIC Educational Resources Information Center

    Environmental Protection Agency, Research Triangle Park, NC. Air Pollution Training Inst.

    This Operator's Manual is a supplement to a self-instructional course prepared for the United States Environmental Protection Agency. This publication is the Boiler Room Handbook for operating and maintaining the boiler and the boiler room. As the student completes this handbook, he is putting together a manual for running his own boiler. The…

  6. High Efficiency - Reduced Emissions Boiler Systems for Steam, Heat, and Processing

    DTIC Science & Technology

    2012-07-01

    enable energy saving necessary for obtaining Energy Star certification for the whole boiler system. Widespread boiler control updates could be possible...adaptability to different boiler and oil/gas burner configurations, and extensibility to operation with nonconventional fuels (e.g., biogas and syngas...typically operating below or slightly above 80%. Higher efficiency improvements can certainly be obtained via boiler replacement and adoption of

  7. Boiler: lossy compression of RNA-seq alignments using coverage vectors

    PubMed Central

    Pritt, Jacob; Langmead, Ben

    2016-01-01

    We describe Boiler, a new software tool for compressing and querying large collections of RNA-seq alignments. Boiler discards most per-read data, keeping only a genomic coverage vector plus a few empirical distributions summarizing the alignments. Since most per-read data is discarded, storage footprint is often much smaller than that achieved by other compression tools. Despite this, the most relevant per-read data can be recovered; we show that Boiler compression has only a slight negative impact on results given by downstream tools for isoform assembly and quantification. Boiler also allows the user to pose fast and useful queries without decompressing the entire file. Boiler is free open source software available from github.com/jpritt/boiler. PMID:27298258

  8. Field Test of Boiler Primary Loop Temperature Controller

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glanville, P.; Rowley, P.; Schroeder, D.

    Beyond these initial system efficiency upgrades are an emerging class of Advanced Load Monitoring (ALM) aftermarket controllers that dynamically respond to the boiler load, with claims of 10% to 30% of fuel savings over a heating season. For hydronic boilers specifically, these devices perform load monitoring, with continuous measurement of supply and, in some cases, return water temperatures. Energy savings from these ALM controllers are derived from dynamic management of the boiler differential, where a microprocessor with memory of past boiler cycles prevents the boiler from firing for a period of time, to limit cycling losses and inefficient operation duringmore » perceived low load conditions. These differ from OTR controllers, which vary boiler setpoint temperatures with ambient conditions while maintaining a fixed differential.« less

  9. Estimation of water level and steam temperature using ensemble Kalman filter square root (EnKF-SR)

    NASA Astrophysics Data System (ADS)

    Herlambang, T.; Mufarrikoh, Z.; Karya, D. F.; Rahmalia, D.

    2018-04-01

    The equipment unit which has the most vital role in the steam-powered electric power plant is boiler. Steam drum boiler is a tank functioning to separate fluida into has phase and liquid phase. The existence in boiler system has a vital role. The controlled variables in the steam drum boiler are water level and the steam temperature. If the water level is higher than the determined level, then the gas phase resulted will contain steam endangering the following process and making the resulted steam going to turbine get less, and the by causing damages to pipes in the boiler. On the contrary, if less than the height of determined water level, the resulted height will result in dry steam likely to endanger steam drum. Thus an error was observed between the determined. This paper studied the implementation of the Ensemble Kalman Filter Square Root (EnKF-SR) method in nonlinear model of the steam drum boiler equation. The computation to estimate the height of water level and the temperature of steam was by simulation using Matlab software. Thus an error was observed between the determined water level and the steam temperature, and that of estimated water level and steam temperature. The result of simulation by Ensemble Kalman Filter Square Root (EnKF-SR) on the nonlinear model of steam drum boiler showed that the error was less than 2%. The implementation of EnKF-SR on the steam drum boiler r model comprises of three simulations, each of which generates 200, 300 and 400 ensembles. The best simulation exhibited the error between the real condition and the estimated result, by generating 400 ensemble. The simulation in water level in order of 0.00002145 m, whereas in the steam temperature was some 0.00002121 kelvin.

  10. 46 CFR 63.01-3 - Scope and applicability.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING AUTOMATIC AUXILIARY... automatic auxiliary boilers, automatic heating boilers, automatic waste heat boilers, donkey boilers... control systems) used for the generation of steam and/or oxidation of ordinary waste materials and garbage...

  11. 46 CFR 63.01-3 - Scope and applicability.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING AUTOMATIC AUXILIARY... automatic auxiliary boilers, automatic heating boilers, automatic waste heat boilers, donkey boilers... control systems) used for the generation of steam and/or oxidation of ordinary waste materials and garbage...

  12. SNAP-8 refractory boiler development program

    NASA Technical Reports Server (NTRS)

    Fuller, R. A.

    1974-01-01

    Performance and endurance tests of the SNAP-8, SN-1 refractory metal boiler are described. The tests were successful and indicated that the boiler heat transfer area could be reduced significantly primarily because of the wetting characteristics of mercury on tantalum in a contaminant-free environment. A continuous endurance test of more than 10,000 hours was conducted without noticeable change in the thermal performance of the boiler. A conclusion of the metallographic examination of the boiler following the endurance test was that expected boiler life would be of the order of 40,000 hours at observed corrosion rates.

  13. Electrostatic precipitator performance and trace element emissions from two Kraft recovery boilers.

    PubMed

    Lind, Terttaliisa; Hokkinen, Jouni; Jokiniemi, Jorma K; Hillamo, Risto; Makkonen, Ulla; Raukola, Antti; Rintanen, Jaakko; Saviharju, Kari

    2006-01-15

    Fine particle emissions from combustion sources have gained attention recently due to their adverse effects on human health. The emission depends on the combustion process, fuel, and particulate removal technology. Particle concentrations at Kraft recovery boiler exits are very high, and the boilers are typically equipped with electrostatic precipitators (ESP). However, little data are available on the ESP performance in recovery boilers. Particle concentrations and size distributions were determined at two modern, operating recovery boilers. In addition, we determined the fractional collection efficiency of the ESPs by simultaneous measurements at the ESP inlet and outlet and the particulate emissions of trace metals. The particle mass concentration atthe ESP inlet was 11-24 g/Nm3 at the two boilers. Particle emissions were 30-40 mg/ Nm3 at boiler A and 12-15 mg/Nm3 at boiler B. The particle size distributions had a major particle mode at around 1 microm. These fume particles contained most of the particle mass. The main components in the particles were sodium and sulfate with minor amounts of chloride, potassium, and presumably some carbonate. The ESP collection efficiency was 99.6-99.8% at boiler A and 99.9% at boiler B. The particle penetration through the ESP was below 0.6% in the entire fume particle size range of 0.3-3 microm. Trace element emissions from both boilers were well below the limit values set by EU directive for waste incineration.

  14. POLLUTANT CONTROL TECHNIQUES FOR PACKAGE BOILERS: HARDWARE MODIFICATIONS AND ALTERNATE FUELS

    EPA Science Inventory

    The report gives results of investigations of four ways to control nitrogen oxide (NOx) emissions from package boilers (both field operating boilers and boiler simulators): (1) variations in combustor operating procedure; (2) combustion modification (flue gas recirculation and st...

  15. RDF (Refuse Derived Fuel) Utilization in a Navy Stoker Coal-Fired Boiler.

    DTIC Science & Technology

    1984-10-01

    the energy production in any coal-fired boiler conversion consideration. The selection of the actual RDF to be used in a converted boiler should be... industrial boilers by gathering information from the Navy Energy and Environmental Support Activity, engineering field divi- sions, and field...activities. Currently the Navy has 27 industrial size boilers firing coal as a primary fuel and 10 firing coal as a secondary fuel. The four principal factors

  16. N2O FIELD STUDY

    EPA Science Inventory

    The report gives results of measurements of nitrous oxide (N2O) emissions from coal-fired utility boilers at three electric power generating stations. Six units were tested, two at each site, including sizes ranging from 165 to 700 MW. Several manufacturers and boiler firing type...

  17. Characterization of carbonaceous aerosols emitted from outdoor wood boilers

    EPA Science Inventory

    This study examines the chemical properties of carbonaceous aerosols emitted from different outdoor wood-fired boiler (OWB) technologies including two cord-wood heaters, a pellet heater, and a multistage gasifier/combustor. The effect of fuel type [red oak wood (Quercus rubra), w...

  18. 12. Forward end of Boiler Room showing open firing doors ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. Forward end of Boiler Room showing open firing doors for boilers. Note ladderway retracted overhead by which firemen entered and left Boiler Room. Coal ejectors shown at extreme left of view. - Steamboat TICONDEROGA, Shelburne Museum Route 7, Shelburne, Chittenden County, VT

  19. 49 CFR 230.47 - Boiler number.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., DEPARTMENT OF TRANSPORTATION STEAM LOCOMOTIVE INSPECTION AND MAINTENANCE STANDARDS Boilers and Appurtenances Steam Gauges § 230.47 Boiler number. (a) Generally. The builder's number of the boiler, if known, shall be stamped on the steam dome or manhole flange. If the builder's number cannot be obtained, an...

  20. Report of the Acquisition Cycle Task Force. 1977 Summer Study

    DTIC Science & Technology

    1978-03-15

    selection and a decision to change from pressure-fired to conventional boilers . These delays extended into the building period and resulted in additional...delays in the program. The acquisition plan was standard for the era. De- lays were caused by decisions made to change the sonar and the boiler design...design changes in the sonar and boiler installation, as well as L C -34 In. V1 CD In - .5 -~j S~ cx cn~~~4 u- L n 1 . WI8 PAG. IS MT QUALtTY PUZCA=LX C-35

  1. Study of the possibility of thermal utilization of contaminated water in low-power boilers

    NASA Astrophysics Data System (ADS)

    Roslyakov, P. V.; Proskurin, Y. V.; Zaichenko, M. N.

    2017-09-01

    The utilization of water contaminated with oil products is a topical problem for thermal power plants and boiler houses. It is reasonable to use special water treatment equipment only for large power engineering and industry facilities. Thermal utilization of contaminated water in boiler furnaces is proposed as an alternative version of its utilization. Since there are hot-water fire-tube boilers at many enterprises, it is necessary to study the possibility of thermal utilization of water contaminated with oil products in their furnaces. The object of this study is a KV-GM-2.0 boiler with a heating power of 2 MW. The pressurized burner developed at the Moscow Power Engineering Institute, National Research University, was used as a burner device for supplying liquid fuel. The computational investigations were performed on the basis of the computer simulation of processes of liquid fuel atomization, mixing, ignition, and burnout; in addition, the formation of nitrogen oxides was simulated on the basis of ANSYS Fluent computational dynamics software packages, taking into account radiative and convective heat transfer. Analysis of the results of numerical experiments on the combined supply of crude oil and water contaminated with oil products has shown that the thermal utilization of contaminated water in fire-tube boilers cannot be recommended. The main causes here are the impingement of oil droplets on the walls of the flame tube, as well as the delay in combustion and increased emissions of nitrogen oxides. The thermal utilization of contaminated water combined with diesel fuel can be arranged provided that the water consumption is not more than 3%; however, this increases the emission of nitrogen oxides. The further increase in contaminated water consumption will lead to the reduction of the reliability of the combustion process.

  2. INTELLIGENT MONITORING SYSTEM WITH HIGH TEMPERATURE DISTRIBUTED FIBEROPTIC SENSOR FOR POWER PLANT COMBUSTION PROCESSES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kwang Y. Lee; Stuart S. Yin; Andre Boheman

    2004-12-26

    The objective of the proposed work is to develop an intelligent distributed fiber optical sensor system for real-time monitoring of high temperature in a boiler furnace in power plants. Of particular interest is the estimation of spatial and temporal distributions of high temperatures within a boiler furnace, which will be essential in assessing and controlling the mechanisms that form and remove pollutants at the source, such as NOx. The basic approach in developing the proposed sensor system is three fold: (1) development of high temperature distributed fiber optical sensor capable of measuring temperatures greater than 2000 C degree with spatialmore » resolution of less than 1 cm; (2) development of distributed parameter system (DPS) models to map the three-dimensional (3D) temperature distribution for the furnace; and (3) development of an intelligent monitoring system for real-time monitoring of the 3D boiler temperature distribution. Under Task 1, improvement was made on the performance of in-fiber grating fabricated in single crystal sapphire fibers, test was performed on the grating performance of single crystal sapphire fiber with new fabrication methods, and the fabricated grating was applied to high temperature sensor. Under Task 2, models obtained from 3-D modeling of the Demonstration Boiler were used to study relationships between temperature and NOx, as the multi-dimensionality of such systems are most comparable with real-life boiler systems. Studies show that in boiler systems with no swirl, the distributed temperature sensor may provide information sufficient to predict trends of NOx at the boiler exit. Under Task 3, we investigate a mathematical approach to extrapolation of the temperature distribution within a power plant boiler facility, using a combination of a modified neural network architecture and semigroup theory. The 3D temperature data is furnished by the Penn State Energy Institute using FLUENT. Given a set of empirical data with no analytic expression, we first develop an analytic description and then extend that model along a single axis.« less

  3. 46 CFR 52.01-130 - Installation.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 2 2013-10-01 2013-10-01 false Installation. 52.01-130 Section 52.01-130 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS General Requirements... the gas passages from the operating boilers. (2) Each main power boiler and auxiliary boiler shall be...

  4. 46 CFR 52.01-130 - Installation.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false Installation. 52.01-130 Section 52.01-130 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS General Requirements... the gas passages from the operating boilers. (2) Each main power boiler and auxiliary boiler shall be...

  5. 46 CFR 52.01-130 - Installation.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Installation. 52.01-130 Section 52.01-130 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS General Requirements... the gas passages from the operating boilers. (2) Each main power boiler and auxiliary boiler shall be...

  6. 46 CFR 52.01-130 - Installation.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Installation. 52.01-130 Section 52.01-130 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS General Requirements... the gas passages from the operating boilers. (2) Each main power boiler and auxiliary boiler shall be...

  7. National Emission Standards for Hazardous Air Pollutants (NESHAP) for Area Source Boilers Tune-up Guides

    EPA Pesticide Factsheets

    This page contains two tune-up guides for area source boilers for industrial, commercial, and institutional boilers and process heaters. The first guide is for owners and operators, and the second is for technicians for the area source boilers.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oland, CB

    Boiler owners and operators who need additional generating capacity face a number of legal, political, environmental, economic, and technical challenges. Their key to success requires selection of an adequately sized low-emission boiler and combustion equipment that can be operated in compliance with emission standards established by state and federal regulatory agencies. Recognizing that many issues are involved in making informed selection decisions, the U.S. Department of Energy (DOE), Office of Industrial Technologies (OIT) sponsored efforts at the Oak Ridge National Laboratory (ORNL) to develop a guide for use in choosing low-emission boilers and combustion equipment. To ensure that the guidemore » covers a broad range of technical and regulatory issues of particular interest to the commercial boiler industry, the guide was developed in cooperation with the American Boiler Manufacturers Association (ABMA), the Council of Industrial Boiler Owners (CIBO), and the U.S. Environmental Protection Agency (EPA). The guide presents topics pertaining to industrial, commercial, and institutional (ICI) boilers. Background information about various types of commercially available boilers is provided along with discussions about the fuels that they burn and the emissions that they produce. Also included are discussions about emissions standards and compliance issues, technical details related to emissions control techniques, and other important selection considerations. Although information in the guide is primarily applicable to new ICI boilers, it may also apply to existing boiler installations.« less

  9. Demonstration of coal reburning for cyclone boiler NO{sub x} control. Appendix, Book 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    Based on the industry need for a pilot-scale cyclone boiler simulator, Babcock Wilcox (B&W) designed, fabricated, and installed such a facility at its Alliance Research Center (ARC) in 1985. The project involved conversion of an existing pulverized coal-fired facility to be cyclone-firing capable. Additionally, convective section tube banks were installed in the upper furnace in order to simulate a typical boiler convection pass. The small boiler simulator (SBS) is designed to simulate most fireside aspects of full-size utility boilers such as combustion and flue gas emissions characteristics, fireside deposition, etc. Prior to the design of the pilot-scale cyclone boiler simulator,more » the various cyclone boiler types were reviewed in order to identify the inherent cyclone boiler design characteristics which are applicable to the majority of these boilers. The cyclone boiler characteristics that were reviewed include NO{sub x} emissions, furnace exit gas temperature (FEGT) carbon loss, and total furnace residence time. Previous pilot-scale cyclone-fired furnace experience identified the following concerns: (1) Operability of a small cyclone furnace (e.g., continuous slag tapping capability). (2) The optimum cyclone(s) configuration for the pilot-scale unit. (3) Compatibility of NO{sub x} levels, carbon burnout, cyclone ash carryover to the convection pass, cyclone temperature, furnace residence time, and FEGT.« less

  10. Boiler: lossy compression of RNA-seq alignments using coverage vectors.

    PubMed

    Pritt, Jacob; Langmead, Ben

    2016-09-19

    We describe Boiler, a new software tool for compressing and querying large collections of RNA-seq alignments. Boiler discards most per-read data, keeping only a genomic coverage vector plus a few empirical distributions summarizing the alignments. Since most per-read data is discarded, storage footprint is often much smaller than that achieved by other compression tools. Despite this, the most relevant per-read data can be recovered; we show that Boiler compression has only a slight negative impact on results given by downstream tools for isoform assembly and quantification. Boiler also allows the user to pose fast and useful queries without decompressing the entire file. Boiler is free open source software available from github.com/jpritt/boiler. © The Author(s) 2016. Published by Oxford University Press on behalf of Nucleic Acids Research.

  11. Concept of Heat Recovery from Exhaust Gases

    NASA Astrophysics Data System (ADS)

    Bukowska, Maria; Nowak, Krzysztof; Proszak-Miąsik, Danuta; Rabczak, Sławomir

    2017-10-01

    The theme of the article is to determine the possibility of waste heat recovery and use it to prepare hot water. The scope includes a description of the existing sample of coal-fired boiler plant, the analysis of working condition and heat recovery proposals. For this purpose, a series of calculations necessary to identify the energy effect of exhaust temperature decreasing and transferring recovery heat to hot water processing. Heat recover solutions from the exhaust gases channel between boiler and chimney section were proposed. Estimation for the cost-effectiveness of such a solution was made. All calculations and analysis were performed for typical Polish conditions, for coal-fired boiler plant. Typicality of this solution is manifested by the volatility of the load during the year, due to distribution of heat for heating and hot water, determining the load variation during the day. Analysed system of three boilers in case of load variation allows to operational flexibility and adaptation of the boilers load to the current heat demand. This adaptation requires changes in the operating conditions of boilers and in particular assurance of properly conditions for the combustion of fuel. These conditions have an impact on the existing thermal loss and the overall efficiency of the boiler plant. On the boiler plant efficiency affects particularly exhaust gas temperature and the excess air factor. Increasing the efficiency of boilers plant is possible to reach by following actions: limiting the excess air factor in coal combustion process in boilers and using an additional heat exchanger in the exhaust gas channel outside of boilers (economizer) intended to preheat the hot water.

  12. Tdp studies and tests for C. A. Energia Electrica de Venezuela (enelven) at planta ramon laguna, units RL-17 and RL-10. Volume 3. Unit RL-10 turbine generator condition assessment report and units RL-10 and RL-11 boiler feed pump conditon assessment report. Export trade information

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1991-03-28

    The study, conducted by Babcock and Wilcox, was funded by the U.S. Trade and Development agency on behalf of Enelven. In order to maximize generated power output and minimize operating costs at Planta Ramon Laguna, tests were done to evaluate the condition of equipment at the plant. In order to identify any damage and determine the operating output of each unit, assessments were done of the furnaces, boilers, generators and boiler feed pumps being used in the plant. The report presents the results of these tests. This is the last of three volumes and it is divided into the followingmore » sections: (1) Condition Assessment of Unit RL-10 Turbine-Generator; (2) Condition Assessment of Unit RL-10 and RL-11 Boiler Feed Pumps.« less

  13. Alternative control techniques document: NOx emissions from industrial/commercial/institutional (ICI) boilers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1994-03-01

    Industrial, commercial, and institutional (ICI) boilers have been identified as a category that emits more than 25 tons of oxides of nitrogen (NOx) per year. This alternative control techniques (ACT) document provides technical information for use by State and local agencies to develop and implement regulatory programs to control NOx emissions from ICI boilers. Additional ACT documents are being developed for other stationary source categories. Chapter 2 summarizes the findings of this study. Chapter 3 presents information on the ICI boiler types, fuels, operation, and industry applications. Chapter 4 discusses NOx formation and uncontrolled NOx emission factors. Chapter 5 coversmore » alternative control techniques and achievable controlled emission levels. Chapter 6 presents the cost and cost effectiveness of each control technique. Chapter 7 describes environmental and energy impacts associated with implementing the NOx control techniques. Finally, Appendices A through G provide the detailed data used in this study to evaluate uncontrolled and controlled emissions and the costs of controls for several retrofit scenarios.« less

  14. 46 CFR 176.812 - Pressure vessels and boilers.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Pressure vessels and boilers. 176.812 Section 176.812... TONS) INSPECTION AND CERTIFICATION Material Inspections § 176.812 Pressure vessels and boilers. (a.... (b) Periodic inspection and testing requirements for boilers are contained in § 61.05 in subchapter F...

  15. 49 CFR 230.47 - Boiler number.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Boiler number. 230.47 Section 230.47... Steam Gauges § 230.47 Boiler number. (a) Generally. The builder's number of the boiler, if known, shall be stamped on the steam dome or manhole flange. If the builder's number cannot be obtained, an...

  16. 49 CFR 230.47 - Boiler number.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Boiler number. 230.47 Section 230.47... Steam Gauges § 230.47 Boiler number. (a) Generally. The builder's number of the boiler, if known, shall be stamped on the steam dome or manhole flange. If the builder's number cannot be obtained, an...

  17. 49 CFR 230.47 - Boiler number.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Boiler number. 230.47 Section 230.47... Steam Gauges § 230.47 Boiler number. (a) Generally. The builder's number of the boiler, if known, shall be stamped on the steam dome or manhole flange. If the builder's number cannot be obtained, an...

  18. 49 CFR 230.47 - Boiler number.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Boiler number. 230.47 Section 230.47... Steam Gauges § 230.47 Boiler number. (a) Generally. The builder's number of the boiler, if known, shall be stamped on the steam dome or manhole flange. If the builder's number cannot be obtained, an...

  19. A comprehensive study of combustion products generated from pulverized peat combustion in the furnace of BKZ-210-140F steam boiler

    NASA Astrophysics Data System (ADS)

    Kuzmin, V. A.; Zagrai, I. A.

    2017-11-01

    The experimental and theoretical study of combustion products has been carried out for the conditions of pulverized peat combustion in BKZ-210-140F steam boiler. Sampling has been performed in different parts of the boiler system in order to determine the chemical composition, radiative properties and dispersity of slag and ash particles. The chemical composition of particles was determined using the method of x-ray fluorescence analysis. Shapes and sizes of the particles were determined by means of electron scanning microscopy. The histograms and the particle size distribution functions were computed. The calculation of components of the gaseous phase was based on the combustion characteristics of the original fuel. The software package of calculation of thermal radiation of combustion products from peat combustion was used to simulate emission characteristics (flux densities and emissivity factors). The dependence of emission characteristics on the temperature level and on the wavelength has been defined. On the basis of the analysis of emission characteristics the authors give some recommendations how to determine the temperature of peat combustion products in the furnace of BKZ-210-140F steam boiler. The findings can be used to measure the combustion products temperature, support temperature control in peat combustion and solve the problem of boiler furnace slagging.

  20. The peats of Costa Rica

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thayer, G.R.; Williamson, K.D. Jr.; Ramirez, O.

    The authors compare the competitive position of peat for energy with coal, oil, and cogenerative systems in gasifiers and solid-fuel boilers. They also explore the possibility for peat use in industry. To identify the major factors, they analyze costs using a Los Alamos levelized cost code, and they study parametric costs, comparing peat production in constant dollars with interest rates and return on investment. They consider costs of processing plant construction, sizes and kinds of boilers, retrofitting, peat drying, and mining methods. They examine mining requirements for Moin, Changuinola, and El Cairo and review wet mining and dewatering methods. Peatmore » can, indeed, be competitive with other energy sources, but this depends on the ratio of fuel costs to boiler costs. This ratio is nearly constant in comparison with cogeneration in a steam-only production system. For grate boilers using Costa Rican high-ash peat, and for small nonautomatic boilers now used in Costa Rica, the authors recommend combustion tests. An appendix contains a preliminary mining plan and cost estimate for the El Cairo peat deposit. 8 refs., 43 figs., 19 tabs.« less

  1. Providing Boiler Inspections at US Army Installations: How to Perform Internal/Operational, Efficiency, and Emissions Testing

    DTIC Science & Technology

    2013-08-01

    corrosion can be found on tubes , tubesheets, and in steam- drums, most often near the waterline in steam boilers . Oxygen pitting can also occur anywhere...components present in the feedwater onto wetted boiler surfaces including fire- tubes and water- tubes . Since scale is a good insulator, the thicker...steel surfaces of a steam boiler . However, heavier scale accumulates on the lower steel surfaces of the tubes , mud-drum, and boiler shell. SLUDGE

  2. Estimation of efficiency of the heat supply system based on a boiler house and a wind turbine in the northern environment

    NASA Astrophysics Data System (ADS)

    Bezhan, A. V.; Minin, V. A.

    2017-03-01

    This article describes a methodological approach to defining indoor air temperature in buildings heated by a power supply unit consisting of a boiler house and a wind-driven power plant (WDPP). We discuss a heating option for a residential building in the windy conditions of Murmansk city. We proved that, during the periods of strong wind, a WDPP can partially or fully satisfy the heat demand and sometimes even create a surplus of energy. During low wind weather, almost all loads are handled by the boiler house. We considered a possibility to accumulate the surplus energy obtained from a WDPP during strong wind by increasing the temperature in the whole building up to 25°C and further using the accumulated heat during the lowwind period when indoor air temperature may fall below 20°C. This allows saving organic fuel in the boiler house. We demonstrated how indoor air temperature in the building may change throughout the year when using the surplus energy from the WDPP due to thermal storage capacitance of the building. We also provided the results of study, showing favorable energy-related effects of using a WDPP along with the boiler house. It was determined that engaging a WDPP in fulfilling the diagram of heating loads promotes the decrease in the boiler house's contribution to heat supply by 30 to 50%, and using the surplus energy from the WDPP and thermal storage capacitance of the building allows reducing the contribution of the boiler house by 5-15% more in certain months.

  3. Engineering and organizational solutions for improvement of engineering and economic characteristics of the TPE-216 boilers equipped with MV-3300/800/490 pulverizing fans

    NASA Astrophysics Data System (ADS)

    Kirillov, M. V.; Safronov, P. G.

    2014-07-01

    Efficiency of coal-fired boilers is determined in many respects by optimal operation of the coal-pulverizing plants that are increasingly frequently equipped with pulverizing fans. By an example of retrofitted MV-3300/800/490 pulverizing fans, the effects of different factors on the performance and economic efficiency of the coal-pulverizing plants are analyzed. The experience gained in retrofitting MV-3300/800/490 pulverizing fans by introducing the three-crusher operation mode of a TPE-216 boiler employing the internal recirculation and a blading device in the classifier was also studied. Optimization of the boiler's operation mode was made when switching over from the four-crusher to the three-crusher mode, which considerably improved the engineering and economic characteristics.

  4. Fossil plant startup advisor: Volume 2, User's manual for a startup model: Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dixon, R.R.; Kraje, N.B.

    1988-12-01

    These instructions describe how to use the dynamic model of a fossil power plant on the diskette at the back of this document. The model runs on an IBM PC, XT or AT. It was developed as part of an EPRI study on fossil startup problems; RP1184-4. The purpose of the model was to provide a tool to demonstrate problems encountered during startups and potential solutions proposed by various industry experts. Consequently, the accuracy and fidelity of the model was not critical, but rather the ability to operate in various startup configurations was more important. An MMS model of themore » cycling unit at COLLINS STATION of Commonwealth Edison served as the basis for the model. Some simplifications were introduced to allow it to run on the PC faster than realtime. The most significant of these is the steam property curves. The saturation properties used are reasonable over the entire operating range, but the superheated steam properties are highly inaccurate at low pressures and low temperatures. This limitation does not, however, diminish the value of the model in demonstrating startup problems or in evaluating the relative merits of one solution over another. On the positive side, the model has both a superheater bypass system and a turbine bypass system. Either bypass can be used separately, or they can be used together (something that appears desirable but no utility has been wealthy enough to try yet). In addition, it provides an excellent tool for understanding the operation of a drum type boiler and both superheater and turbine bypass systems. 14 figs.« less

  5. Performance of casting aluminum-silicon alloy condensing heating exchanger for gas-fired boiler

    NASA Astrophysics Data System (ADS)

    Cao, Weixue; Liu, Fengguo; You, Xue-yi

    2018-07-01

    Condensing gas boilers are widely used due to their high heat efficiency, which comes from their ability to use the recoverable sensible heat and latent heat in flue gas. The condensed water of the boiler exhaust has strong corrosion effect on the heat exchanger, which restricts the further application of the condensing gas boiler. In recent years, a casting aluminum-silicon alloy (CASA), which boasts good anti-corrosion properties, has been introduced to condensing hot water boilers. In this paper, the heat transfer performance, CO and NOx emission concentrations and CASA corrosion resistance of a heat exchanger are studied by an efficiency bench test of the gas-fired boiler. The experimental results are compared with heat exchangers produced by Honeywell and Beka. The results show that the excess air coefficient has a significant effect on the heat efficiency and CO and NOx emission of the CASA water heater. When the excess air coefficient of the CASA gas boiler is 1.3, the CO and NOx emission concentration of the flue gas satisfies the design requirements, and the heat efficiency of water heater is 90.8%. In addition, with the increase of heat load rate, the heat transfer coefficient of the heat exchanger and the heat efficiency of the water heater are increased. However, when the heat load rate is at 90%, the NOx emission in the exhaust gas is the highest. Furthermore, when the temperature of flue gas is below 57 °C, the condensation of water vapor occurs, and the pH of condensed water is in the 2.5 5.5 range. The study shows that CASA water heater has good corrosion resistance and a high heat efficiency of 88%. Compared with the heat exchangers produced by Honeywell and Beka, there is still much work to do in optimizing and improving the water heater.

  6. Performance of casting aluminum-silicon alloy condensing heating exchanger for gas-fired boiler

    NASA Astrophysics Data System (ADS)

    Cao, Weixue; Liu, Fengguo; You, Xue-yi

    2018-01-01

    Condensing gas boilers are widely used due to their high heat efficiency, which comes from their ability to use the recoverable sensible heat and latent heat in flue gas. The condensed water of the boiler exhaust has strong corrosion effect on the heat exchanger, which restricts the further application of the condensing gas boiler. In recent years, a casting aluminum-silicon alloy (CASA), which boasts good anti-corrosion properties, has been introduced to condensing hot water boilers. In this paper, the heat transfer performance, CO and NOx emission concentrations and CASA corrosion resistance of a heat exchanger are studied by an efficiency bench test of the gas-fired boiler. The experimental results are compared with heat exchangers produced by Honeywell and Beka. The results show that the excess air coefficient has a significant effect on the heat efficiency and CO and NOx emission of the CASA water heater. When the excess air coefficient of the CASA gas boiler is 1.3, the CO and NOx emission concentration of the flue gas satisfies the design requirements, and the heat efficiency of water heater is 90.8%. In addition, with the increase of heat load rate, the heat transfer coefficient of the heat exchanger and the heat efficiency of the water heater are increased. However, when the heat load rate is at 90%, the NOx emission in the exhaust gas is the highest. Furthermore, when the temperature of flue gas is below 57 °C, the condensation of water vapor occurs, and the pH of condensed water is in the 2.5 5.5 range. The study shows that CASA water heater has good corrosion resistance and a high heat efficiency of 88%. Compared with the heat exchangers produced by Honeywell and Beka, there is still much work to do in optimizing and improving the water heater.

  7. Overview of Boiler House and Sheet Metal and Electrical Shops ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Overview of Boiler House and Sheet Metal and Electrical Shops Building (center - with single large chimney), note the monitor on the original section of the Boiler House Building, view facing north - Kahului Cannery, Plant No. 28, Boiler House, Sheet Metal and Electrical Shops, 120 Kane Street, Kahului, Maui County, HI

  8. 16 CFR Appendix G8 to Part 305 - Boilers (Electric)

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 16 Commercial Practices 1 2014-01-01 2014-01-01 false Boilers (Electric) G8 Appendix G8 to Part... LABELING RULEâ) Appendix G8 to Part 305—Boilers (Electric) Type Range of annual fuel utilization efficiencies (AFUEs) Low High Electric Boilers 100 100 [78 FR 8377, Feb. 6, 2013] ...

  9. 46 CFR 167.15-25 - Inspection standards for hulls, boilers and machinery.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Inspection standards for hulls, boilers and machinery... SCHOOLS PUBLIC NAUTICAL SCHOOL SHIPS Inspections § 167.15-25 Inspection standards for hulls, boilers and... Classing Steel Vessels” regarding the construction of hulls, boilers and machinery in effect on the date of...

  10. 46 CFR 71.15-1 - Standards in inspection of hulls, boilers, and machinery.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Standards in inspection of hulls, boilers, and machinery... VESSELS INSPECTION AND CERTIFICATION Inspection of Vessels § 71.15-1 Standards in inspection of hulls, boilers, and machinery. In the inspection of hulls, boilers, and machinery of vessels, the standards...

  11. 30 CFR 57.13030 - Boilers.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Boilers. 57.13030 Section 57.13030 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Compressed Air and Boilers § 57.13030 Boilers. (a) Fired pressure vessels ...

  12. 30 CFR 57.13030 - Boilers.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Boilers. 57.13030 Section 57.13030 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Compressed Air and Boilers § 57.13030 Boilers. (a) Fired pressure vessels ...

  13. 30 CFR 57.13030 - Boilers.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Boilers. 57.13030 Section 57.13030 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Compressed Air and Boilers § 57.13030 Boilers. (a) Fired pressure vessels ...

  14. 46 CFR 109.421 - Report of repairs to boilers and pressure vessels.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Report of repairs to boilers and pressure vessels. 109... Report of repairs to boilers and pressure vessels. Before making repairs, except normal repairs and maintenance such as replacement of valves or pressure seals, to boilers or unfired pressure vessels in...

  15. 46 CFR 196.30-1 - Repairs to boilers and pressure vessels.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Repairs to boilers and pressure vessels. 196.30-1... VESSELS OPERATIONS Reports of Accidents, Repairs, and Unsafe Equipment § 196.30-1 Repairs to boilers and pressure vessels. (a) Before making any repairs to boilers or unfired pressure vessels, the Chief Engineer...

  16. 7 CFR 51.2833 - U.S. No. 1 Boilers.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false U.S. No. 1 Boilers. 51.2833 Section 51.2833 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards...) Grades § 51.2833 U.S. No. 1 Boilers. U.S. No. 1 Boilers consists of onions which meet all the...

  17. 46 CFR 52.01-35 - Auxiliary, donkey, fired thermal fluid heater, and heating boilers.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... heating boilers. 52.01-35 Section 52.01-35 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS General Requirements § 52.01-35 Auxiliary, donkey, fired thermal fluid heater, and heating boilers. (a) To determine the appropriate part of the regulations where...

  18. 46 CFR 115.812 - Pressure vessels and boilers.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Pressure vessels and boilers. 115.812 Section 115.812... CERTIFICATION Material Inspections § 115.812 Pressure vessels and boilers. (a) Pressure vessels must be tested... testing requirements for boilers are contained in § 61.05 in subchapter F of this chapter. [CGD 85-080, 61...

  19. 40 CFR 270.66 - Permits for boilers and industrial furnaces burning hazardous waste.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... blended, and blending ratios. (3) A detailed engineering description of the boiler or industrial furnace... 40 Protection of Environment 27 2011-07-01 2011-07-01 false Permits for boilers and industrial... PROGRAM Special Forms of Permits § 270.66 Permits for boilers and industrial furnaces burning hazardous...

  20. 40 CFR 270.66 - Permits for boilers and industrial furnaces burning hazardous waste.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... blended, and blending ratios. (3) A detailed engineering description of the boiler or industrial furnace... 40 Protection of Environment 28 2013-07-01 2013-07-01 false Permits for boilers and industrial... PROGRAM Special Forms of Permits § 270.66 Permits for boilers and industrial furnaces burning hazardous...

  1. 40 CFR 270.66 - Permits for boilers and industrial furnaces burning hazardous waste.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... blended, and blending ratios. (3) A detailed engineering description of the boiler or industrial furnace... 40 Protection of Environment 28 2012-07-01 2012-07-01 false Permits for boilers and industrial... PROGRAM Special Forms of Permits § 270.66 Permits for boilers and industrial furnaces burning hazardous...

  2. 40 CFR 270.66 - Permits for boilers and industrial furnaces burning hazardous waste.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... blended, and blending ratios. (3) A detailed engineering description of the boiler or industrial furnace... 40 Protection of Environment 27 2014-07-01 2014-07-01 false Permits for boilers and industrial... PROGRAM Special Forms of Permits § 270.66 Permits for boilers and industrial furnaces burning hazardous...

  3. 40 CFR 270.66 - Permits for boilers and industrial furnaces burning hazardous waste.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... blended, and blending ratios. (3) A detailed engineering description of the boiler or industrial furnace... 40 Protection of Environment 26 2010-07-01 2010-07-01 false Permits for boilers and industrial... PROGRAM Special Forms of Permits § 270.66 Permits for boilers and industrial furnaces burning hazardous...

  4. 21 CFR 173.310 - Boiler water additives.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 3 2013-04-01 2013-04-01 false Boiler water additives. 173.310 Section 173.310... CONSUMPTION Specific Usage Additives § 173.310 Boiler water additives. Boiler water additives may be safely... water. Copolymer contains not more than 0.5 percent by weight of acrylic acid monomer (dry weight basis...

  5. 21 CFR 173.310 - Boiler water additives.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 3 2012-04-01 2012-04-01 false Boiler water additives. 173.310 Section 173.310... CONSUMPTION Specific Usage Additives § 173.310 Boiler water additives. Boiler water additives may be safely... water. Copolymer contains not more than 0.5 percent by weight of acrylic acid monomer (dry weight basis...

  6. 21 CFR 173.310 - Boiler water additives.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 3 2011-04-01 2011-04-01 false Boiler water additives. 173.310 Section 173.310... CONSUMPTION Specific Usage Additives § 173.310 Boiler water additives. Boiler water additives may be safely... water. Copolymer contains not more than 0.5 percent by weight of acrylic acid monomer (dry weight basis...

  7. 40 CFR 65.149 - Boilers and process heaters.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) A boiler or process heater with a design heat input capacity of 44 megawatts (150 million British... hazardous waste for which the owner or operator meets either of the following requirements: (A) The boiler...). If an owner or operator elects to use a boiler or process heater to replace an existing recovery...

  8. 40 CFR 65.149 - Boilers and process heaters.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) A boiler or process heater with a design heat input capacity of 44 megawatts (150 million British... hazardous waste for which the owner or operator meets either of the following requirements: (A) The boiler...). If an owner or operator elects to use a boiler or process heater to replace an existing recovery...

  9. Application of Boiler Op for combustion optimization at PEPCO

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maines, P.; Williams, S.; Levy, E.

    1997-09-01

    Title IV requires the reduction of NOx at all stations within the PEPCO system. To assist PEPCO plant personnel in achieving low heat rates while meeting NOx targets, Lehigh University`s Energy Research Center and PEPCO developed a new combustion optimization software package called Boiler Op. The Boiler Op code contains an expert system, neural networks and an optimization algorithm. The expert system guides the plant engineer through a series of parametric boiler tests, required for the development of a comprehensive boiler database. The data are then analyzed by the neural networks and optimization algorithm to provide results on the boilermore » control settings which result in the best possible heat rate at a target NOx level or produce minimum NOx. Boiler Op has been used at both Potomac River and Morgantown Stations to help PEPCO engineers optimize combustion. With the use of Boiler Op, Morgantown Station operates under low NOx restrictions and continues to achieve record heat rate values, similar to pre-retrofit conditions. Potomac River Station achieves the regulatory NOx limit through the use of Boiler Op recommended control settings and without NOx burners. Importantly, any software like Boiler Op cannot be used alone. Its application must be in concert with human intelligence to ensure unit safety, reliability and accurate data collection.« less

  10. Research, Development and Demonstration of Bio-Mass Boiler for Food Industry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fisher, Steve; Knapp, David

    2012-07-01

    Frito-Lay is working to reduce carbon emissions from their manufacturing plants. As part of this effort, they invested in a biomass-fired boiler at the Topeka, Kansas, plant. Frito-Lay partnered with Burns & McDonnell Engineering, Inc. and CPL Systems, Inc., to design and construct a steam producing boiler using carbon neutral fuels such as wood wastes (e.g. tree bark), shipping pallets, and used rubber vehicle tires. The U.S. Department of Energy (DOE) joined with Frito-Lay, Burns & McDonnell, and CPL to analyze the reductions in carbon dioxide (CO 2) emissions that result from use of biomass-fired boilers in the food manufacturingmore » environment. DOE support provided for the data collection and analysis, and reporting necessary to evaluate boiler efficiencies and reductions in CO 2 emissions. The Frito-Lay biomass-fired boiler has resulted in significant reductions in CO 2 emissions from the Topeka production facility. The use of natural gas has been reduced by 400 to 420 million standard cubic feet per year with corresponding reductions of 24,000 to 25,000 tons of CO 2. The boiler does require auxiliary functions, however, that are unnecessary for a gas-fired boiler. These include heavy motors and fans for moving fuel and firing the boiler, trucks and equipment for delivering the fuel and moving at the boiler plant, and chippers for preparing the fuel prior to delivery. Each of these operations requires the combustion of fossil fuels or electricity and has associated CO 2 emissions. Even after accounting for each of these auxiliary processes, however, the biomass-fired boiler results in net emission reductions of 22,500 to 23,500 tons of CO 2 per year.« less

  11. Super Boiler: Packed Media/Transport Membrane Boiler Development and Demonstration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liss, William E; Cygan, David F

    2013-04-17

    Gas Technology Institute (GTI) and Cleaver-Brooks developed a new gas-fired steam generation system the Super Boiler for increased energy efficiency, reduced equipment size, and reduced emissions. The system consists of a firetube boiler with a unique staged furnace design, a two-stage burner system with engineered internal recirculation and inter-stage cooling integral to the boiler, unique convective pass design with extended internal surfaces for enhanced heat transfer, and a novel integrated heat recovery system to extract maximum energy from the flue gas. With these combined innovations, the Super Boiler technical goals were set at 94% HHV fuel efficiency, operation on naturalmore » gas with <5 ppmv NOx (referenced to 3%O2), and 50% smaller than conventional boilers of similar steam output. To demonstrate these technical goals, the project culminated in the industrial demonstration of this new high-efficiency technology on a 300 HP boiler at Clement Pappas, a juice bottler located in Ontario, California. The Super Boiler combustion system is based on two stage combustion which combines air staging, internal flue gas recirculation, inter-stage cooling, and unique fuel-air mixing technology to achieve low emissions rather than external flue gas recirculation which is most commonly used today. The two-stage combustion provides lower emissions because of the integrated design of the boiler and combustion system which permit precise control of peak flame temperatures in both primary and secondary stages of combustion. To reduce equipment size, the Super Boiler's dual furnace design increases radiant heat transfer to the furnace walls, allowing shorter overall furnace length, and also employs convective tubes with extended surfaces that increase heat transfer by up to 18-fold compared to conventional bare tubes. In this way, a two-pass boiler can achieve the same efficiency as a traditional three or four-pass firetube boiler design. The Super Boiler is consequently up to 50% smaller in footprint, has a smaller diameter, and is up to 50% lower in weight, resulting in very compact design with reduced material cost and labor costs, while requiring less boiler room floor space. For enhanced energy efficiency, the heat recovery system uses a transport membrane condenser (TMC), a humidifying air heater (HAH), and a split-stage economizer to extract maximum energy from the flue gas. The TMC is a new innovation that pulls a major portion of water vapor produced by the combustion process from the flue gases along with its sensible and latent heat. This results in nearly 100% transfer of heat to the boiler feed water. The HAH improves the effectiveness of the TMC, particularly in steam systems that do not have a large amount of cold makeup water. In addition, the HAH humidifies the combustion air to reduce NOx formation. The split-stage economizer preheats boiler feed water in the same way as a conventional economizer, but extracts more heat by working in tandem with the TMC and HAH to reduce flue gas temperature. These components are designed to work synergistically to achieve energy efficiencies of 92-94% which is 10-15% higher than today's typical firetube boilers.« less

  12. The Council of Industrial Boiler Owners special project on non-utility fossil fuel ash classification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Svendsen, R.L.

    1996-12-31

    Information is outlined on the Council of Industrial Boiler Owners (CIBO) special project on non-utility fossil fuel ash classification. Data are presented on; current (1996) regulatory status of fossil-fuel combustion wastes; FBC technology identified for further study; CIBO special project methods; Bevill amendment study factors; data collection; and CIBO special project status.

  13. How much Energy is Embodied in your Central Heating Boiler?

    NASA Astrophysics Data System (ADS)

    Koubogiannis, D.; Nouhou, C.

    2016-11-01

    Life Cycle Analysis (LCA) is an important tool in current research to quantitatively assess energy consumption and environmental impact of a building. In the context of LCA, the Embodied Energy (EE) related to the building and the corresponding Embodied CO2 emissions are valuable data. In such a case, these data concern the constitutive materials of the building and any subsystem, component or equipment in it. Usually, after calculating the mass of these materials, embodied energy values are estimated multiplying them by the corresponding EE coefficients concerning the production of these materials (EEMP). However, apart from transportation energy costs, another part of EE is that consumed for the manufacturing of any item as a finished product. The present work focuses on the manufacturing EE (EEMFG) of central heating boilers in Hellenic dwellings. Six typical boilers of different types are studied. Each of them is analyzed to its constitutive materials and its EEMP is estimated. For four of them, the boiler house where it was constructed in Greece was visited and data were collected. Based on them the corresponding boiler EEMFG values are estimated. The results concerning the EE for material production and manufacturing, as well as the results concerning the corresponding ECO2 values are discussed and assessed. Benchmark values correlating EE and ECO2 with the mass or the heat rate of the boiler are extracted.

  14. Computer method for identification of boiler transfer functions

    NASA Technical Reports Server (NTRS)

    Miles, J. H.

    1971-01-01

    An iterative computer method is described for identifying boiler transfer functions using frequency response data. An objective penalized performance measure and a nonlinear minimization technique are used to cause the locus of points generated by a transfer function to resemble the locus of points obtained from frequency response measurements. Different transfer functions can be tried until a satisfactory empirical transfer function to the system is found. To illustrate the method, some examples and some results from a study of a set of data consisting of measurements of the inlet impedance of a single tube forced flow boiler with inserts are given.

  15. 46 CFR 52.01-135 - Inspection and tests (modifies PG-90 through PG-100).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...). (a) Requirements. Inspection and test of boilers and boiler pressure parts shall be as indicated in PG-90 through PG-100 of section I of the ASME Boiler and Pressure Vessel Code (incorporated by...-91 of section I of the ASME Boiler and Pressure Vessel Code (incorporated by reference; see 46 CFR 52...

  16. 46 CFR 63.25-3 - Electric hot water supply boilers.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Electric hot water supply boilers. 63.25-3 Section 63.25... water supply boilers. (a) Electric hot water supply boilers that have a capacity not greater than 454... section except the periodic testing required by paragraph (j) of this section. Electric hot water supply...

  17. 40 CFR 76.5 - NOX emission limitations for Group 1 boilers.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... wall-fired boiler (other than units applying cell burner technology) shall not discharge, or allow to... input on an annual average basis for tangentially fired boilers. (2) 0.50 lb/mmBtu of heat input on an annual average basis for dry bottom wall-fired boilers (other than units applying cell burner technology...

  18. 46 CFR 196.15-15 - Examination of boilers and machinery.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Examination of boilers and machinery. 196.15-15 Section... VESSELS OPERATIONS Test, Drills, and Inspections § 196.15-15 Examination of boilers and machinery. (a) It shall be the duty of the chief engineer when he assumes charge of the boilers and machinery of a vessel...

  19. 46 CFR 78.33-1 - Repairs of boiler and pressure vessels.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Repairs of boiler and pressure vessels. 78.33-1 Section... OPERATIONS Reports of Accidents, Repairs, and Unsafe Equipment § 78.33-1 Repairs of boiler and pressure vessels. (a) Before making any repairs to boilers or unfired pressure vessels, the chief engineer shall...

  20. 46 CFR 97.15-15 - Examination of boilers and machinery.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Examination of boilers and machinery. 97.15-15 Section... VESSELS OPERATIONS Tests, Drills, and Inspections § 97.15-15 Examination of boilers and machinery. It shall be the duty of the chief engineer when assuming charge of the boilers and machinery of a vessel to...

  1. 46 CFR 78.17-30 - Examination of boilers and machinery.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Examination of boilers and machinery. 78.17-30 Section... OPERATIONS Tests, Drills, and Inspections § 78.17-30 Examination of boilers and machinery. It shall be the duty of the chief engineer when assuming charge of the boilers and machinery of a vessel to examine...

  2. 46 CFR 32.35-1 - Boilers and machinery-TB/ALL.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Boilers and machinery-TB/ALL. 32.35-1 Section 32.35-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS SPECIAL EQUIPMENT, MACHINERY, AND HULL REQUIREMENTS Main and Auxiliary Machinery § 32.35-1 Boilers and machinery—TB/ALL. Boilers, main and auxiliary...

  3. 46 CFR 50.05-5 - Existing boilers, pressure vessels or piping systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Existing boilers, pressure vessels or piping systems. 50... ENGINEERING GENERAL PROVISIONS Application § 50.05-5 Existing boilers, pressure vessels or piping systems. (a) Whenever doubt exists as to the safety of an existing boiler, pressure vessel, or piping system, the marine...

  4. 46 CFR 97.30-1 - Repairs to boilers and pressure vessels.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Repairs to boilers and pressure vessels. 97.30-1 Section... VESSELS OPERATIONS Reports of Accidents, Repairs, and Unsafe Equipment § 97.30-1 Repairs to boilers and pressure vessels. (a) Before making any repairs to boilers or unfired pressure vessels, the chief engineer...

  5. 46 CFR 167.65-60 - Examination of boilers and machinery by engineer.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Examination of boilers and machinery by engineer. 167.65... SCHOOLS PUBLIC NAUTICAL SCHOOL SHIPS Special Operating Requirements § 167.65-60 Examination of boilers and machinery by engineer. It shall be the duty of an engineer when he assumes charge of the boilers and...

  6. 49 CFR Appendix D to Part 230 - Civil Penalty Schedule

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... the boiler 1,000 2,000 230.36Hydrostatic testing of boilers: (a) Failure to perform hydrostatic test of boiler as required 1,500 3,000 (b) Failure to properly perform hydrostatic test 1,500 3,000 (c) Failure to properly inspect boiler after conducting hydrostatic test above MAWP 1,500 3,000 230.37 Failure...

  7. 16 CFR Appendix G7 to Part 305 - Boilers (Oil)

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 16 Commercial Practices 1 2014-01-01 2014-01-01 false Boilers (Oil) G7 Appendix G7 to Part 305... RULEâ) Appendix G7 to Part 305—Boilers (Oil) Type Range of annual fuel utilization efficiencies (AFUEs) Low High Oil Boilers Manufactured Before the Compliance Date of DOE Regional Standards for Non...

  8. Evaluation of thermal overload in boiler operators.

    PubMed

    Braga, Camila Soares; Rodrigues, Valéria Antônia Justino; Campos, Julio César Costa; de Souza, Amaury Paulo; Minette, Luciano José; de Moraes, Angêlo Casali; Sensato, Guilherme Luciano

    2012-01-01

    The Brazilians educational institutions need a large energy demand for the operation of laundries, restaurants and accommodation of students. Much of that energy comes from steam generated in boilers with wood fuel. The laboral activity in boiler may present problems for the operator's health due to exposure to excessive heat, and its operation has a high degree of risk. This paper describes an analysis made the conditions of thermal environment in the operation of a B category boiler, located at a Higher Education Institution, located in the Zona da Mata Mineira The equipments used to collect data were Meter WBGT of the Heat Index; Meter of Wet Bulb Index and Globe Thermometer (WBGT); Politeste Instruments, an anemometer and an Infrared Thermometer. By the application of questionnaires, the second phase consisted of collecting data on environmental factors (temperature natural environment, globe temperature, relative humidity and air velocity). The study concluded that during the period evaluated, the activity had thermal overload.

  9. Studying the effectiveness of using pneumoimpulsive technology for cleaning the platen surfaces of the PK-38 boiler at the Nazarovo district power station

    NASA Astrophysics Data System (ADS)

    Agliulin, S. G.; Nikolaev, S. F.; Zvegintsev, V. I.; Yurkin, I. A.; Shabanov, I. I.; Palkin, V. F.; Sergienko, S. P.; Vlasov, S. M.

    2014-09-01

    A new pneumoimpulsive technology, central to which is an impact effect of air jet on ash deposits, was proposed for carrying out continuous preventive cleaning of the platens installed in the steam superheater primary and secondary paths of the PK-38 boiler at the Nazarovo district power station. The pneumoimpulsive cleaning system was mounted in the PK-38 boiler unit no. 6A, and the cleaning system tests were carried out during field operation of the boiler. Owing to the use of the proposed cleaning system, long-term (for no less than 3 months of observations) slag-free operation of the platen surfaces was achieved in the range of steam loads from 215 to 235 t/h with the average load equal to 225 t/h at furnace gas temperatures upstream of the platens equal to 1220-1250°C.

  10. Optimized scheme in coal-fired boiler combustion based on information entropy and modified K-prototypes algorithm

    NASA Astrophysics Data System (ADS)

    Gu, Hui; Zhu, Hongxia; Cui, Yanfeng; Si, Fengqi; Xue, Rui; Xi, Han; Zhang, Jiayu

    2018-06-01

    An integrated combustion optimization scheme is proposed for the combined considering the restriction in coal-fired boiler combustion efficiency and outlet NOx emissions. Continuous attribute discretization and reduction techniques are handled as optimization preparation by E-Cluster and C_RED methods, in which the segmentation numbers don't need to be provided in advance and can be continuously adapted with data characters. In order to obtain results of multi-objections with clustering method for mixed data, a modified K-prototypes algorithm is then proposed. This algorithm can be divided into two stages as K-prototypes algorithm for clustering number self-adaptation and clustering for multi-objective optimization, respectively. Field tests were carried out at a 660 MW coal-fired boiler to provide real data as a case study for controllable attribute discretization and reduction in boiler system and obtaining optimization parameters considering [ maxηb, minyNOx ] multi-objective rule.

  11. 40 CFR Table 3 to Subpart Ddddd of... - Operating Limits for Boilers and Process Heaters With Mercury Emission Limits and Boilers and...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Process Heaters With Mercury Emission Limits and Boilers and Process Heaters That Choose To Comply With... Heaters With Mercury Emission Limits and Boilers and Process Heaters That Choose To Comply With the... operating limits: If you demonstrate compliance with applicable mercury and/or total selected metals...

  12. 33 CFR 145.10 - Locations and number of fire extinguishers required.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... vicinity of exits, either inside or outside of spaces. machinery spaces Gas-fired boilers B-II (CO2 or dry chemical) 2 required. Gas-fired boilers B-V 1 required. 1 Oil-fired boilers B-II 2 required. Oil-fired boilers B-V 2 required. 1 Internal combustion or gas turbine engines B-II 1 for each engine. 2 Electric...

  13. 33 CFR 145.10 - Locations and number of fire extinguishers required.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... vicinity of exits, either inside or outside of spaces. machinery spaces Gas-fired boilers B-II (CO2 or dry chemical) 2 required. Gas-fired boilers B-V 1 required. 1 Oil-fired boilers B-II 2 required. Oil-fired boilers B-V 2 required. 1 Internal combustion or gas turbine engines B-II 1 for each engine. 2 Electric...

  14. 33 CFR 145.10 - Locations and number of fire extinguishers required.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... vicinity of exits, either inside or outside of spaces. machinery spaces Gas-fired boilers B-II (CO2 or dry chemical) 2 required. Gas-fired boilers B-V 1 required. 1 Oil-fired boilers B-II 2 required. Oil-fired boilers B-V 2 required. 1 Internal combustion or gas turbine engines B-II 1 for each engine. 2 Electric...

  15. 33 CFR 145.10 - Locations and number of fire extinguishers required.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... vicinity of exits, either inside or outside of spaces. machinery spaces Gas-fired boilers B-II (CO2 or dry chemical) 2 required. Gas-fired boilers B-V 1 required. 1 Oil-fired boilers B-II 2 required. Oil-fired boilers B-V 2 required. 1 Internal combustion or gas turbine engines B-II 1 for each engine. 2 Electric...

  16. 33 CFR 145.10 - Locations and number of fire extinguishers required.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... vicinity of exits, either inside or outside of spaces. machinery spaces Gas-fired boilers B-II (CO2 or dry chemical) 2 required. Gas-fired boilers B-V 1 required. 1 Oil-fired boilers B-II 2 required. Oil-fired boilers B-V 2 required. 1 Internal combustion or gas turbine engines B-II 1 for each engine. 2 Electric...

  17. Biomass boiler conversion potential in the eastern United States

    Treesearch

    Charles D. Ray; Li Ma; Thomas Wilson; Daniel Wilson; Lew McCreery; Janice K. Wiedenbeck

    2013-01-01

    The U.S. is the world's leading consumer of primary energy. A large fraction of this energy is used in boiler installations to generate steam and hot water for heating applications. It is estimated there are total 163,000 industrial and commercial boilers in use in the United States of all sizes. This paper characterizes the commercial and industrial boilers in...

  18. 46 CFR 61.05-5 - Preparation of boilers for inspection and test.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Preparation of boilers for inspection and test. 61.05-5 Section 61.05-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PERIODIC TESTS AND INSPECTIONS Tests and Inspections of Boilers § 61.05-5 Preparation of boilers for inspection and test. (a) For internal inspectio...

  19. 35. VIEW LOOKING EAST IN SOUTH END OF EAST BOILER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    35. VIEW LOOKING EAST IN SOUTH END OF EAST BOILER ROOM. CYLINDRICAL TANKS ARE WORTHINGTON DEAERATORS. THESE REMOVED AIR FROM BOILER FEED WATER TO MINIMIZE CORROSION AND PITTING OF THE BOILER TUBES. AIR REMOVAL ALSO HELPED AVOID THE FORMATION OF FOAM IN THE SYSTEM. - New York, New Haven & Hartford Railroad, Cos Cob Power Plant, Sound Shore Drive, Greenwich, Fairfield County, CT

  20. A Guide for Recertification of Ground Based Pressure Vessels and Liquid Holding Tanks

    DTIC Science & Technology

    1987-12-15

    Boiler and Pressure Vessel Code , Section...Requirements 202 Calculate Vessel MAWP Using ASME Boiler and Pressure Vessel Code Section VUI, Division 1. 203 Assess Vessel MAWP Using ASME Boiler and Pressure Vessel Code Section...Engineers (ASME) Boiler and Pressure Vessel Code (B&PV) Section VIll, Division 1, or other applicable standard. This activity involves the

  1. Effective Use of Weld Metal Yield Strength for HY-Steels

    DTIC Science & Technology

    1983-01-01

    Boiler and Pressure Vessel Code The ASME Boiler and Pressure Vessel Code (B&PV Code) is divided...As noted earlier, the ASME Boiler and Pressure Vessel Code makes only one exception to its overall philosophy of matching weld-metal strength and...material where toughness is of primary importance. REFERENCES American Society of Mechanical Engineers, Boiler and Pressure Vessel

  2. 46 CFR 167.65-70 - Reports of accidents, repairs, and unsafe boilers and machinery by engineers.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Reports of accidents, repairs, and unsafe boilers and... of accidents, repairs, and unsafe boilers and machinery by engineers. (a) Before making repairs to a boiler of a nautical school ship the engineer in charge shall report, in writing, the nature of such...

  3. 46 CFR 35.25-5 - Repairs of boilers and unfired pressure vessels and reports of repairs or accidents by chief...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Repairs of boilers and unfired pressure vessels and..., DEPARTMENT OF HOMELAND SECURITY TANK VESSELS OPERATIONS Engine Department § 35.25-5 Repairs of boilers and... any repairs to boilers or unfired pressure vessels, the chief engineer shall submit a report covering...

  4. 46 CFR 35.25-1 - Examination of boilers and machinery by engineer-T/ALL.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Examination of boilers and machinery by engineer-T/ALL... Engine Department § 35.25-1 Examination of boilers and machinery by engineer—T/ALL. It shall be the duty of an engineer when assuming charge of the boilers to examine the same forthwith and thoroughly. If...

  5. 46 CFR 35.25-1 - Examination of boilers and machinery by engineer-T/ALL.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 1 2011-10-01 2011-10-01 false Examination of boilers and machinery by engineer-T/ALL... Engine Department § 35.25-1 Examination of boilers and machinery by engineer—T/ALL. It shall be the duty of an engineer when assuming charge of the boilers to examine the same forthwith and thoroughly. If...

  6. 46 CFR 35.25-1 - Examination of boilers and machinery by engineer-T/ALL.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 1 2012-10-01 2012-10-01 false Examination of boilers and machinery by engineer-T/ALL... Engine Department § 35.25-1 Examination of boilers and machinery by engineer—T/ALL. It shall be the duty of an engineer when assuming charge of the boilers to examine the same forthwith and thoroughly. If...

  7. 46 CFR 35.25-1 - Examination of boilers and machinery by engineer-T/ALL.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 1 2013-10-01 2013-10-01 false Examination of boilers and machinery by engineer-T/ALL... Engine Department § 35.25-1 Examination of boilers and machinery by engineer—T/ALL. It shall be the duty of an engineer when assuming charge of the boilers to examine the same forthwith and thoroughly. If...

  8. Sootblowing optimization for improved boiler performance

    DOEpatents

    James, John Robert; McDermott, John; Piche, Stephen; Pickard, Fred; Parikh, Neel J.

    2012-12-25

    A sootblowing control system that uses predictive models to bridge the gap between sootblower operation and boiler performance goals. The system uses predictive modeling and heuristics (rules) associated with different zones in a boiler to determine an optimal sequence of sootblower operations and achieve boiler performance targets. The system performs the sootblower optimization while observing any operational constraints placed on the sootblowers.

  9. Sootblowing optimization for improved boiler performance

    DOEpatents

    James, John Robert; McDermott, John; Piche, Stephen; Pickard, Fred; Parikh, Neel J

    2013-07-30

    A sootblowing control system that uses predictive models to bridge the gap between sootblower operation and boiler performance goals. The system uses predictive modeling and heuristics (rules) associated with different zones in a boiler to determine an optimal sequence of sootblower operations and achieve boiler performance targets. The system performs the sootblower optimization while observing any operational constraints placed on the sootblowers.

  10. A novel direct-fired porous-medium boiler

    NASA Astrophysics Data System (ADS)

    Prasartkaew, Boonrit

    2018-01-01

    Nowadays, power and heat generation systems pay an important role in all economic sectors. These systems are mainly based on combustion reaction and operated under the second law of thermodynamics. A conventional boilers, a main component of heat and power generators, have thermal efficiency in the range of 70 to 85%, mainly owing to they have flue gas heat loss. This paper proposes a novel type of boiler, called a Direct-fired Porous-medium Boiler (DPB). Due to being operated without flue gas heat loss, its thermal efficiency cloud be approximately close to 100%. The steam produced from the proposed boiler; however, is not pure water steam. It is the composite gases of steam and combustion-product-gases. This paper aims at presenting the working concept and reporting the experimental results on the performance of the proposed boiler. The experiments of various operating parameters were performed and collected data were used for the performance analysis. The experimental results demonstrated that the proposed boiler can be operated as well as the conceptual design and then it is promising. It can be possibly further developed to be a high efficiency boiler by means of reducing or suppressing the surface heat loss with better insulator and/or refractory lined.

  11. First Experiences with the New Chalmers Gasifier

    NASA Astrophysics Data System (ADS)

    Thunman, H.; Seemann, M. C.

    During summer 2007 a 2-6 MWth indirect gasification section was integrated into the loop of the existing 82➀2 MWth circulating fluidized bed boiler at Chalmers University. With help of a particle distributor the gasification unit is connected to the loop after the cyclone. Hot bed material entrained from the boiler is so transferred to the gasifier providing the heat for the production of a nearly nitrogen free product gas. Non-gasified char is returned together with the bed material into the boiler and converted. Biomass can be fed into both sections; the boiler and the gasifier. The gasification is separated from the boiler via two loop seals and a particle distributer, directing particles either back to the boiler or into the gasification section. For that reason the CFB boiler can be operated even after the retrofit independently, just like before, or in combined combustion/gasification mode. This possibility keeps the risk for a retrofit low. As, furthermore, the investment costs for the integration are considerably lower than standalone gasification units of that size, the retrofit is an easy way to extend the potential of a CFB Boiler towards bi- and tri-generation (heat, power, fuel) and enter new markets.

  12. Effect of fuels and domestic heating appliance types on emission factors of selected organic pollutants.

    PubMed

    Šyc, Michal; Horák, Jiří; Hopan, František; Krpec, Kamil; Tomšej, Tomáš; Ocelka, Tomáš; Pekárek, Vladimír

    2011-11-01

    This study reports on the first complex data set of emission factors (EFs) of selected pollutants from combustion of five fuel types (lignite, bituminous coal, spruce, beech, and maize) in six different domestic heating appliances of various combustion designs. The effect of fuel as well as the effect of boiler type was studied. In total, 46 combustion runs were performed, during which numerous EFs were measured, including the EFs of particulate matter (PM), carbon monoxide, polyaromatic hydrocarbons (PAH), hexachlorobenzene (HxCBz), polychlorinated dibenzo-p-dioxins and furans (PCDD/F), etc. The highest EFs of nonchlorinated pollutants were measured for old-type boilers with over-fire and under-fire designs and with manual stoking and natural draft. Emissions of the above-mentioned pollutants from modern-type boilers (automatic, downdraft) were 10 times lower or more. The decisive factor for emission rate of nonchlorinated pollutants was the type of appliance; the type of fuel plays only a minor role. Emissions of chlorinated pollutants were proportional mainly to the chlorine content in fuel, but the type of appliance also influenced the rate of emissions significantly. Surprisingly, higher EFs of PCDD/F from combustion of chlorinated bituminous coal were observed for modern-type boilers (downdraft, automatic) than for old-type ones. On the other hand, when bituminous coal was burned, higher emissions of HxCBz were found for old-type boilers than for modern-type ones.

  13. [Predicting low NOx combustion property of a coal-fired boiler].

    PubMed

    Zhou, Hao; Mao, Jianbo; Chi, Zuohe; Jiang, Xiao; Wang, Zhenhua; Cen, Kefa

    2002-03-01

    More attention was paid to the low NOx combustion property of the high capacity tangential firing boiler, but the NOx emission and unburned carbon content in fly ash of coal burned boiler were complicated, they were affected by many factors, such as coal character, boiler's load, air distribution, boiler style, burner style, furnace temperature, excess air ratio, pulverized coal fineness and the uniformity of the air and coal distribution, etc. In this paper, the NOx emission property and unburned carbon content in fly ash of a 600 MW utility tangentially firing coal burned boiler was experimentally investigated, and taking advantage of the nonlinear dynamics characteristics and self-learning characteristics of artificial neural network, an artificial neural network model on low NOx combustion property of the high capacity boiler was developed and verified. The results illustrated that such a model can predicate the NOx emission concentration and unburned carbon content under various operating conditions, if combined with the optimization algorithm, the operator can find the best operation condition of the low NOx combustion.

  14. Coal reburning for cyclone boiler NO{sub x} control demonstration. Quarterly report No. 6, July--September, 1991

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1991-12-31

    It is the objective of the Coal Reburning for Cyclone Boiler NO{sub x} Control Project to fully establish that the cola reburning clean coal technology offers cost-effective alternatives to cyclone operating electric utilities for overall oxides of nitrogen control. The project will evaluate the applicability of the reburning technology for reducing NO{sub x} emissions in full scale cyclone-fired boilers which use coal as a primary fuel. The performance goals while burning coal are: (1) Greater than 50 percent reduction in NO{sub x} emissions, as referenced to the uncontrolled (baseline) conditions at full load. (2) No serious impact on cyclone combustormore » operation, boiler efficiency or boiler fireside performance (corrosion and deposition), or boiler ash removal system performance.« less

  15. Coal reburning for cyclone boiler NO sub x control demonstration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1991-01-01

    It is the objective of the Coal Reburning for Cyclone Boiler NO{sub x} Control Project to fully establish that the cola reburning clean coal technology offers cost-effective alternatives to cyclone operating electric utilities for overall oxides of nitrogen control. The project will evaluate the applicability of the reburning technology for reducing NO{sub x} emissions in full scale cyclone-fired boilers which use coal as a primary fuel. The performance goals while burning coal are: (1) Greater than 50 percent reduction in NO{sub x} emissions, as referenced to the uncontrolled (baseline) conditions at full load. (2) No serious impact on cyclone combustormore » operation, boiler efficiency or boiler fireside performance (corrosion and deposition), or boiler ash removal system performance.« less

  16. White Earth Biomass/Biogas Feasibility Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Triplett, Michael

    2015-03-12

    The White Earth Nation examined the feasibility of cost savings and fossil energy reduction through the installation of biogas/biomass boiler at the tribal casino. The study rejected biogas options due to availability and site constraints, but found a favorable environment for technical and financial feasibility of installing a 5 MMBtu hot water boiler system to offset 60-70 percent of current fuel oil and propane usage.

  17. The correlation between acoustic and magnetic properties in the long working metal boiler drum with the parameters of the electron microscope

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ababkov, Nikolai, E-mail: n.ababkov@rambler.ru; Smirnov, Alexander, E-mail: galvas.kem@gmail.com

    The present paper presents comparative analysis of measurement results of acoustic and magnetic properties in long working metal of boiler drums and the results obtained by methods of electronic microscopy. The structure of the metal sample from the fracture zone to the base metal (metal working sample long) and the center of the base metal before welding (weld metal sample) was investigated by electron microscopy. Studies performed by spectral acoustic, magnetic noise and electron microscopic methods were conducted on the same plots and the same samples of long working and weld metal of high-pressure boiler drums. The analysis of researchmore » results showed high sensitivity of spectral-acoustic and magnetic-noise methods to definition changes of microstructure parameters. Practical application of spectral-acoustic and magnetic noise NDT method is possible for the detection of irregularities and changes in structural and phase state of the long working and weld metal of boiler drums, made of a special molybdenum steel (such as 20M). The above technique can be used to evaluate the structure and physical-mechanical properties of the long working metal of boiler drums in the energy sector.« less

  18. Six decades of industrial water treatment (1915-1975)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maguire, J.J.

    1976-01-01

    An extensive account of water treatment beginning with the internal treatment of boiler water used for steam generation in the teens to the later treatment of cooling water and industrial process water. In the teens external softening of boiler makeup water was recommended by various processes. In the twenties water problems intensified and research on boiler water scaling began and continued through the thirties. The mechanism of scale formation was studied, and a new Navy boiler compound was adopted. Langelier's Saturation Index work in 1936 served as a basis for early control of scaling by cooling water. In the fortiesmore » other controls and removers were recommended, and antifoam patents issued. In 1950 Berk proved nitrate an effective inhibitor, and in 1951 influence of boiler design and operation on steam contamination was presented. Internal chemical treatment programs continued to be refined in the sixties with synthetic dispersing agents, and Chelant treatments continued to dominate the seventies, with inspection times extended 2-3 years by their use. Besides treatment of industrial waters, evaluation of results also demanded attention and water quality standards were of concern. Research continues to develop more effective synthetic and naturally-occurring organic agents.« less

  19. 13. RW Meyer Sugar Mill: 18761889. Engine and boiler house, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    13. RW Meyer Sugar Mill: 1876-1889. Engine and boiler house, ca. 1881. Locomotive-type, fire-tube, portable boiler, no. I model. Manufactured by Ames Iron Works, Oswego, New York, 1879. 120 lbs./sq. in. working pressure, 66 sq. ft. heating surface in tubes. View: Historical view, 1934, from T.T. Waterman Collection, Hawaiian Sugar Planters' Association. View shows engine and boiler house structure intact. The water and pressure gauge to the right of the boiler are in more complete condition than in 1978 views. - R. W. Meyer Sugar Mill, State Route 47, Kualapuu, Maui County, HI

  20. Recovery Act: Oxy-Combustion Techology Development for Industrial-Scale Boiler Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Levasseur, Armand

    2014-04-30

    Alstom Power Inc. (Alstom), under U.S. DOE/NETL Cooperative Agreement No. DE-NT0005290, is conducting a development program to generate detailed technical information needed for application of oxy-combustion technology. The program is designed to provide the necessary information and understanding for the next step of large-scale commercial demonstration of oxy combustion in tangentially fired boilers and to accelerate the commercialization of this technology. The main project objectives include: • Design and develop an innovative oxyfuel system for existing tangentially-fired boiler units that minimizes overall capital investment and operating costs. • Evaluate performance of oxyfuel tangentially fired boiler systems in pilot scale testsmore » at Alstom’s 15 MWth tangentially fired Boiler Simulation Facility (BSF). • Address technical gaps for the design of oxyfuel commercial utility boilers by focused testing and improvement of engineering and simulation tools. • Develop the design, performance and costs for a demonstration scale oxyfuel boiler and auxiliary systems. • Develop the design and costs for both industrial and utility commercial scale reference oxyfuel boilers and auxiliary systems that are optimized for overall plant performance and cost. • Define key design considerations and develop general guidelines for application of results to utility and different industrial applications. The project was initiated in October 2008 and the scope extended in 2010 under an ARRA award. The project completion date was April 30, 2014. Central to the project is 15 MWth testing in the BSF, which provided in-depth understanding of oxy-combustion under boiler conditions, detailed data for improvement of design tools, and key information for application to commercial scale oxy-fired boiler design. Eight comprehensive 15 MWth oxy-fired test campaigns were performed with different coals, providing detailed data on combustion, emissions, and thermal behavior over a matrix of fuels, oxyprocess variables and boiler design parameters. Significant improvement of CFD modeling tools and validation against 15 MWth experimental data has been completed. Oxy-boiler demonstration and large reference designs have been developed, supported with the information and knowledge gained from the 15 MWth testing. The results from the 15 MWth testing in the BSF and complimentary bench-scale testing are addressed in this volume (Volume II) of the final report. The results of the modeling efforts (Volume III) and the oxy boiler design efforts (Volume IV) are reported in separate volumes.« less

  1. Looking northeast across transfer table pit at Boiler Shop (Bldg. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Looking northeast across transfer table pit at Boiler Shop (Bldg. 152) - Atchison, Topeka, Santa Fe Railroad, Albuquerque Shops, Boiler Shop, 908 Second Street, Southwest, Albuquerque, Bernalillo County, NM

  2. 10 CFR 431.86 - Uniform test method for the measurement of energy efficiency of commercial packaged boilers.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Boiler That is Capable of Supplying Either Steam or Hot Water—(A) Testing. For purposes of EPCA, before... supplying either steam or hot water either by testing the boiler in the steam mode or by testing it in both... supplying either steam or hot water either by testing the boiler for both efficiencies in steam mode, or by...

  3. Preparing Technical Requirements for Third Party Contracting of Army Facilities

    DTIC Science & Technology

    1993-06-01

    Boiler and Pressure Vessel Code Sec 9 Welding and Brazing Qualifications B 16.1 Cast Iron Pipe Flanges and Flanged...Control Terminology for Heating, Ventilating, Air Conditioning American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code B40.1...American National Standards Institute (ANSI) Boiler and Pressure Vessel Code (ASME) 125 Boilers and Pressure Vessels Code (ASTM) B31 Power

  4. 46 CFR 53.05-1 - Safety valve requirements for steam boilers (modifies HG-400 and HG-401).

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Safety valve requirements for steam boilers (modifies HG-400 and HG-401). 53.05-1 Section 53.05-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING HEATING BOILERS Pressure Relieving Devices (Article 4) § 53.05-1 Safety valve requirements for steam boilers (modifies HG...

  5. 46 CFR 53.05-2 - Relief valve requirements for hot water boilers (modifies HG-400.2).

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Relief valve requirements for hot water boilers (modifies HG-400.2). 53.05-2 Section 53.05-2 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING HEATING BOILERS Pressure Relieving Devices (Article 4) § 53.05-2 Relief valve requirements for hot water boilers (modifies HG...

  6. 46 CFR 53.05-2 - Relief valve requirements for hot water boilers (modifies HG-400.2).

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Relief valve requirements for hot water boilers (modifies HG-400.2). 53.05-2 Section 53.05-2 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING HEATING BOILERS Pressure Relieving Devices (Article 4) § 53.05-2 Relief valve requirements for hot water boilers (modifies HG...

  7. 46 CFR 53.05-2 - Relief valve requirements for hot water boilers (modifies HG-400.2).

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 2 2013-10-01 2013-10-01 false Relief valve requirements for hot water boilers (modifies HG-400.2). 53.05-2 Section 53.05-2 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING HEATING BOILERS Pressure Relieving Devices (Article 4) § 53.05-2 Relief valve requirements for hot water boilers (modifies HG...

  8. 46 CFR 53.05-1 - Safety valve requirements for steam boilers (modifies HG-400 and HG-401).

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 2 2013-10-01 2013-10-01 false Safety valve requirements for steam boilers (modifies HG-400 and HG-401). 53.05-1 Section 53.05-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING HEATING BOILERS Pressure Relieving Devices (Article 4) § 53.05-1 Safety valve requirements for steam boilers (modifies HG...

  9. 46 CFR 53.05-1 - Safety valve requirements for steam boilers (modifies HG-400 and HG-401).

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false Safety valve requirements for steam boilers (modifies HG-400 and HG-401). 53.05-1 Section 53.05-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING HEATING BOILERS Pressure Relieving Devices (Article 4) § 53.05-1 Safety valve requirements for steam boilers (modifies HG...

  10. 46 CFR 53.05-1 - Safety valve requirements for steam boilers (modifies HG-400 and HG-401).

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Safety valve requirements for steam boilers (modifies HG-400 and HG-401). 53.05-1 Section 53.05-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING HEATING BOILERS Pressure Relieving Devices (Article 4) § 53.05-1 Safety valve requirements for steam boilers (modifies HG...

  11. 46 CFR 53.05-2 - Relief valve requirements for hot water boilers (modifies HG-400.2).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Relief valve requirements for hot water boilers (modifies HG-400.2). 53.05-2 Section 53.05-2 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING HEATING BOILERS Pressure Relieving Devices (Article 4) § 53.05-2 Relief valve requirements for hot water boilers (modifies HG...

  12. High Efficiency - Reduced Emissions Boiler Systems for Steam, Heat, and Processing

    DTIC Science & Technology

    2012-07-01

    obtaining Energy Star certification for the whole boiler system. Widespread boiler control updates could be possible by mandating their adoption and...Measurements of O2 and NOx are obtained by means of automotive grade yttria-stabilized zirconia sensors. This solution combines good sensitivity at...boiler and oil/gas burner configurations, extensibility to operation with nonconventional fuels (e.g. biogas and syngas). Applicability of the

  13. 26. VIEW OF SOUTHERN PORTION OF EAST BOILER ROOM LOOKING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    26. VIEW OF SOUTHERN PORTION OF EAST BOILER ROOM LOOKING EAST AT BOILER 904. BOILER 904 WAS MANUFACTURED BY RILEY STOKER AND INSTALLED IN 1944. ORIGINALLY FUELED BY PULVERIZED COAL, IT WAS CONVERTED TO GAS/OIL OPERATION IN 1978 AND OPERATED UNTIL THE PLANT CLOSED. - New York, New Haven & Hartford Railroad, Cos Cob Power Plant, Sound Shore Drive, Greenwich, Fairfield County, CT

  14. 27. VIEW OF SOUTHERN PORTION OF EAST BOILER ROOM LOOKING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    27. VIEW OF SOUTHERN PORTION OF EAST BOILER ROOM LOOKING EAST AT UPPER PORTION BOILER 904. BOILER 904 WAS MANUFACTURED BY RILEY STOKER AND INSTALLED IN 1944. ORIGINALLY FUELED BY PULVERIZED COAL, IT WAS CONVERTED TO GAS/OIL OPERATION IN 1978 AND OPERATED UNTIL THE PLANT CLOSED. - New York, New Haven & Hartford Railroad, Cos Cob Power Plant, Sound Shore Drive, Greenwich, Fairfield County, CT

  15. 46 CFR 53.05-2 - Relief valve requirements for hot water boilers (modifies HG-400.2).

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false Relief valve requirements for hot water boilers (modifies HG-400.2). 53.05-2 Section 53.05-2 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING HEATING BOILERS Pressure Relieving Devices (Article 4) § 53.05-2 Relief valve requirements for hot water boilers (modifies HG...

  16. 46 CFR 53.05-1 - Safety valve requirements for steam boilers (modifies HG-400 and HG-401).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Safety valve requirements for steam boilers (modifies HG... requirements for steam boilers (modifies HG-400 and HG-401). (a) The pressure relief valve requirements and the safety valve requirements for steam boilers must be as indicated in HG-400 and HG-401 of section IV of...

  17. Combustion of bark and wood waste in the fluidized bed boiler

    NASA Astrophysics Data System (ADS)

    Pleshanov, K. A.; Ionkin, I. L.; Roslyakov, P. V.; Maslov, R. S.; Ragutkin, A. V.; Kondrat'eva, O. E.

    2016-11-01

    In the Energy Development Strategy of Russia for the Period until 2035, special attention is paid to increased use of local fuel kinds—one of which is biofuel, in particular, bark and wood waste (BWW)— whose application at thermal power plants in Russia has been not developed due to the lack of appropriate technologies mastered by domestic energy mechanical engineering. The article describes the experience of BWW combustion in fluidized bed boilers installed on the energy objects of northern European countries. Based on this, reference points were defined (it is the section of boiler air-gas path where initially the approximate temperatures are set), making it possible to carry out a thermal design of a boiler and ensure its operation reliability. Permissible gas temperature at the furnace outlet at BWW combustion amounted to 950-1000°C. Exit gas temperature, depending on the implementation of special measures on protection of air heater from corrosion, amounted to 140-190°C. Recommended hot air temperature is within the range of 200-250°C. Recommendations for determining the boiler furnace dimensions are presented. Based on the presented reference temperatures in the main reference points, the thermal design of hot water boiler of KV-F-116-150 type with 116 MW capacity was carried out. The analysis of the results and comparison of designed boiler characteristics with operating energy boilers, in which a fuel is burned in a fluidized bed, were carried out. It is shown that, with increasing the boiler capacity, the ratio of its heating power Q to the crosssectional area of furnace chamber F rises. For power-generating boiler of thermal capacity of 100 MW, the ratio is within 1.8-2.2MW/m2. The boiler efficiency exceeds 90% in the range of changes of exit gas temperature typical for such equipment.

  18. View of the rear of the electrical department & boiler ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View of the rear of the electrical department & boiler house, behind the upper shops - Johnson Steel Street Rail Company, Electrical Department & Boiler House, 525 Central Avenue, Johnstown, Cambria County, PA

  19. Boiler Shop (Bldg. 152) 150ton Morgan bridge crane, looking west ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Boiler Shop (Bldg. 152) 150-ton Morgan bridge crane, looking west - Atchison, Topeka, Santa Fe Railroad, Albuquerque Shops, Boiler Shop, 908 Second Street, Southwest, Albuquerque, Bernalillo County, NM

  20. Boiler Shop (Bldg. 152) 150ton Morgan bridge crane, looking east ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Boiler Shop (Bldg. 152) 150-ton Morgan bridge crane, looking east - Atchison, Topeka, Santa Fe Railroad, Albuquerque Shops, Boiler Shop, 908 Second Street, Southwest, Albuquerque, Bernalillo County, NM

  1. Identification of boiler inlet transfer functions and estimation of system parameters

    NASA Technical Reports Server (NTRS)

    Miles, J. H.

    1972-01-01

    An iterative computer method is described for identifying boiler transfer functions using frequency response data. An objective penalized performance measure and a nonlinear minimization technique are used to cause the locus of points generated by a transfer function to resemble the locus of points obtained from frequency response measurements. Different transfer functions can be tried until a satisfactory empirical transfer function of the system is found. To illustrate the method, some examples and some results from a study of a set of data consisting of measurements of the inlet impedance of a single tube forced flow boiler with inserts are given.

  2. Screening and Quantification of Aliphatic Primary Alkyl Corrosion Inhibitor Amines in Water Samples by Paper Spray Mass Spectrometry.

    PubMed

    Jjunju, Fred P M; Maher, Simon; Damon, Deidre E; Barrett, Richard M; Syed, S U; Heeren, Ron M A; Taylor, Stephen; Badu-Tawiah, Abraham K

    2016-01-19

    Direct analysis and identification of long chain aliphatic primary diamine Duomeen O (n-oleyl-1,3-diaminopropane), corrosion inhibitor in raw water samples taken from a large medium pressure water tube boiler plant water samples at low LODs (<0.1 pg) has been demonstrated for the first time, without any sample preparation using paper spray mass spectrometry (PS-MS). The presence of Duomeen O in water samples was confirmed via tandem mass spectrometry using collision-induced dissociation and supported by exact mass measurement and reactive paper spray experiments using an LTQ Orbitrap Exactive instrument. Data shown herein indicate that paper spray ambient ionization can be readily used as a rapid and robust method for in situ direct analysis of polymanine corrosion inhibitors in an industrial water boiler plant and other related samples in the water treatment industry. This approach was applied for the analysis of three complex water samples including feedwater, condensate water, and boiler water, all collected from large medium pressure (MP) water tube boiler plants, known to be dosed with varying amounts of polyamine and amine corrosion inhibitor components. Polyamine chemistry is widely used for example in large high pressure (HP) boilers operating in municipal waste and recycling facilities to prevent corrosion of metals. The samples used in this study are from such a facility in Coventry waste treatment facility, U.K., which has 3 × 40 tonne/hour boilers operating at 17.5 bar.

  3. Looking south at a chemical mixing tank for boiler feedwater. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Looking south at a chemical mixing tank for boiler feedwater. - Wheeling-Pittsburgh Steel Corporation, Allenport Works, Boiler House, Route 88 on West bank of Monongahela River, Allenport, Washington County, PA

  4. Program to Train Boiler Operators Developed

    ERIC Educational Resources Information Center

    Chemical and Engineering News, 1978

    1978-01-01

    This program initiated by Nalco Chemical, a major supplier of chemicals for boiler feedwater treatment, uses texts, audiovisual aids, and hands-on experience and is designed to boost the efficiency of boiler operators. (BB)

  5. Looking north at the stokers for boilers numbers 1 through ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Looking north at the stokers for boilers numbers 1 through 4. - Wheeling-Pittsburgh Steel Corporation, Allenport Works, Boiler House, Route 88 on West bank of Monongahela River, Allenport, Washington County, PA

  6. The pressure cold wind system on the impact of industrial boiler economy and security

    NASA Astrophysics Data System (ADS)

    Li, Henan; Qian, Hongli; Jiang, Lei; Yu, Dekai; Li, Guannan; Yuan, Hong

    2017-05-01

    Industrial boiler is one of the most energy-consuming equipment in china, the annual consumption of energy accounts for about one-third of the national energy consumption.Industrial boiler in service at present have several severe problems such as small capacity, low efficiency, high energy consumption and causing severe pollution on environment, the average industrial boiler operation efficiency is only 65%. If the efficiency increased by 15% ∼ 20%, which meet the international advanced level, each year 70 million tons of coal saving and reduce environmental pollution[1]. As energy conservation and emissions reduction becomes the basic national policy of our country, improving the efficiency of industrial boiler energy is facing opportunities and challenges, optimizing the operation mode of the existing units, it is necessary to increase the flexibility of the boiler control.

  7. 9. RW Meyer Sugar Mill: 18761889. Locomotivetype, firetube, portable boiler, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. RW Meyer Sugar Mill: 1876-1889. Locomotive-type, fire-tube, portable boiler, No. 1 model. Manufactured by Ames Iron Works, Oswego, New York, 1879. 120 lbs/sq. inch working pressure, 66 sq. ft. heating surface in tubes. View: from side. The boiler provided steam for steam engine which in turn powered the mill's centrifugals. The section on the left side included the firebox with its surrounding water-legs. The fluted chimney-type structure is the steam port, safety valve, and whistle. Column projecting from side was part of steam pressure and water gauge. Pipe running above boiler carried steam to the engine. Pipe running below boiler provided the boiler feed-water. Cylindrical section included 22 fire-tube surrounded by water. The far right ... - R. W. Meyer Sugar Mill, State Route 47, Kualapuu, Maui County, HI

  8. 46 CFR 53.01-3 - Adoption of section IV of the ASME Boiler and Pressure Vessel Code.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Adoption of section IV of the ASME Boiler and Pressure Vessel Code. 53.01-3 Section 53.01-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING HEATING BOILERS General Requirements § 53.01-3 Adoption of section IV of the ASME Boiler and Pressure Vessel Code. (a) Heating...

  9. 46 CFR 53.01-3 - Adoption of section IV of the ASME Boiler and Pressure Vessel Code.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false Adoption of section IV of the ASME Boiler and Pressure Vessel Code. 53.01-3 Section 53.01-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING HEATING BOILERS General Requirements § 53.01-3 Adoption of section IV of the ASME Boiler and Pressure Vessel Code. (a) Heating...

  10. 46 CFR 52.01-2 - Adoption of section I of the ASME Boiler and Pressure Vessel Code.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Adoption of section I of the ASME Boiler and Pressure Vessel Code. 52.01-2 Section 52.01-2 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS General Requirements § 52.01-2 Adoption of section I of the ASME Boiler and Pressure Vessel Code. (a) Main power...

  11. 46 CFR 52.01-2 - Adoption of section I of the ASME Boiler and Pressure Vessel Code.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Adoption of section I of the ASME Boiler and Pressure Vessel Code. 52.01-2 Section 52.01-2 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS General Requirements § 52.01-2 Adoption of section I of the ASME Boiler and Pressure Vessel Code. (a) Main power...

  12. 46 CFR 53.01-3 - Adoption of section IV of the ASME Boiler and Pressure Vessel Code.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Adoption of section IV of the ASME Boiler and Pressure Vessel Code. 53.01-3 Section 53.01-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING HEATING BOILERS General Requirements § 53.01-3 Adoption of section IV of the ASME Boiler and Pressure Vessel Code. (a) Heating...

  13. 46 CFR 52.01-2 - Adoption of section I of the ASME Boiler and Pressure Vessel Code.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false Adoption of section I of the ASME Boiler and Pressure Vessel Code. 52.01-2 Section 52.01-2 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS General Requirements § 52.01-2 Adoption of section I of the ASME Boiler and Pressure Vessel Code. (a) Main power...

  14. 46 CFR 53.01-3 - Adoption of section IV of the ASME Boiler and Pressure Vessel Code.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 2 2013-10-01 2013-10-01 false Adoption of section IV of the ASME Boiler and Pressure Vessel Code. 53.01-3 Section 53.01-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING HEATING BOILERS General Requirements § 53.01-3 Adoption of section IV of the ASME Boiler and Pressure Vessel Code. (a) Heating...

  15. 46 CFR 52.01-2 - Adoption of section I of the ASME Boiler and Pressure Vessel Code.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Adoption of section I of the ASME Boiler and Pressure Vessel Code. 52.01-2 Section 52.01-2 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS General Requirements § 52.01-2 Adoption of section I of the ASME Boiler and Pressure Vessel Code. (a) Main power...

  16. 46 CFR 52.01-2 - Adoption of section I of the ASME Boiler and Pressure Vessel Code.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 2 2013-10-01 2013-10-01 false Adoption of section I of the ASME Boiler and Pressure Vessel Code. 52.01-2 Section 52.01-2 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS General Requirements § 52.01-2 Adoption of section I of the ASME Boiler and Pressure Vessel Code. (a) Main power...

  17. 46 CFR 53.01-3 - Adoption of section IV of the ASME Boiler and Pressure Vessel Code.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Adoption of section IV of the ASME Boiler and Pressure Vessel Code. 53.01-3 Section 53.01-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING HEATING BOILERS General Requirements § 53.01-3 Adoption of section IV of the ASME Boiler and Pressure Vessel Code. (a) Heating...

  18. Final technical report. In-situ FT-IR monitoring of a black liquor recovery boiler

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    James Markham; Joseph Cosgrove; David Marran

    1999-05-31

    This project developed and tested advanced Fourier transform infrared (FT-IR) instruments for process monitoring of black liquor recovery boilers. The state-of-the-art FT-IR instruments successfully operated in the harsh environment of a black liquor recovery boiler and provided a wealth of real-time process information. Concentrations of multiple gas species were simultaneously monitored in-situ across the combustion flow of the boiler and extractively at the stack. Sensitivity to changes of particulate fume and carryover levels in the process flow were also demonstrated. Boiler set-up and operation is a complex balance of conditions that influence the chemical and physical processes in the combustionmore » flow. Operating parameters include black liquor flow rate, liquor temperature, nozzle pressure, primary air, secondary air, tertiary air, boiler excess oxygen and others. The in-process information provided by the FT-IR monitors can be used as a boiler control tool since species indicative of combustion efficiency (carbon monoxide, methane) and pollutant emissions (sulfur dioxide, hydrochloric acid and fume) were monitored in real-time and observed to fluctuate as operating conditions were varied. A high priority need of the U.S. industrial boiler market is improved measurement and control technology. The sensor technology demonstrated in this project is applicable to the need of industry.« less

  19. 13. Interior, boiler house, at elev. 55' looking west at ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    13. Interior, boiler house, at elev. 55' looking west at retired 300 lb. boilers #11, 10, and 9. - Manchester Street Generating Station, Manchester Street Station, 460 Eddy Street, Providence, Providence County, RI

  20. 46 CFR 52.01-130 - Installation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... that for a cylindrical part of a boiler or a knuckle in the casing of a water-tube boiler, these... as necessary to prevent oil draining into the bilges. (c) Boiler uptakes. (1) Where dampers are...

  1. Looking south at the ash disposal hoppers for boilers numbers ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Looking south at the ash disposal hoppers for boilers numbers 1 through 6. - Wheeling-Pittsburgh Steel Corporation, Allenport Works, Boiler House, Route 88 on West bank of Monongahela River, Allenport, Washington County, PA

  2. Bench-Scale Silicone Process for Low-Cost CO{sub 2} Capture

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vipperla, Ravikumar; Yee, Michael; Steele, Ray

    This report presents system and economic analysis for a carbon capture unit which uses an amino-silicone solvent for CO{sub 2} capture and sequestration (CCS) in a pulverized coal (PC) boiler. The amino-silicone solvent is based on GAP-1 with tri-ethylene glycol (TEG) as a co-solvent. For comparison purposes, the report also shows results for a CCS unit based on a conventional approach using mono-ethanol amine (MEA). At a steam temperature of 395 °C (743 °F), the CCS energy penalty for amino-silicone solvent is only 30.4% which compares to a 35.9% energy penalty for MEA. The increase in COE for the amino-siliconemore » solvent relative to the non-capture case is between 98% and 103% (depending on the solvent cost) which compares to an ~109% COE cost increase for MEA. In summary, the amino-silicone solvent has significant advantages over conventional systems using MEA.« less

  3. In vitro toxicological characterization of particulate emissions from residential biomass heating systems based on old and new technologies

    NASA Astrophysics Data System (ADS)

    Jalava, Pasi I.; Happo, Mikko S.; Kelz, Joachim; Brunner, Thomas; Hakulinen, Pasi; Mäki-Paakkanen, Jorma; Hukkanen, Annika; Jokiniemi, Jorma; Obernberger, Ingwald; Hirvonen, Maija-Riitta

    2012-04-01

    Residential wood combustion causes major effects on the air quality on a global scale. The ambient particulate levels are known to be responsible for severe adverse health effects that include e.g. cardio-respiratory illnesses and cancer related effects, even mortality. It is known that biomass combustion derived emissions are affected by combustion technology, fuel being used and user-related practices. There are also indications that the health related toxicological effects are influenced by these parameters. This study we evaluated toxicological effects of particulate emissions (PM1) from seven different residential wood combusting furnaces. Two appliances i.e. log wood boiler and stove represented old batch combustion technology, whereas stove and tiled stove were designated as new batch combustion as three modern automated boilers were a log wood boiler, a woodchip boiler and a pellet boiler. The PM1 samples from the furnaces were collected in an experimental setup with a Dekati® gravimetric impactor on PTFE filters with the samples being weighed and extracted from the substrates and prior to toxicological analyses. The toxicological analyses were conducted after a 24-hour exposure of the mouse RAW 264.7 macrophage cell line to four doses of emission particle samples and analysis of levels of the proinflammatory cytokine TNFα, chemokine MIP-2, cytotoxicity with three different methods (MTT, PI, cell cycle analysis) and genotoxicity with the comet assay. In the correlation analysis all the toxicological results were compared with the chemical composition of the samples. All the samples induced dose-dependent increases in the studied parameters. Combustion technology greatly affected the emissions and the concomitant toxicological responses. The modern automated boilers were usually the least potent inducers of most of the parameters while emissions from the old technology log wood boiler were the most potent. In correlation analysis, the PAH and other organic composition and inorganic ash composition affected the toxicological responses differently. In conclusion, combustion technology largely affects the particulate emissions and their toxic potential this being reflected in substantially larger responses in devices with incomplete combustion. These differences become emphasized when the large emission factors from old technology appliances are taken into account.

  4. 32. VIEW OF BASEMENT BELOW BOILER 904 LOOKING SOUTHEAST AT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    32. VIEW OF BASEMENT BELOW BOILER 904 LOOKING SOUTHEAST AT TURBINE DRIVEN FORCED DRAFT FAN FOR BOILER 904. - New York, New Haven & Hartford Railroad, Cos Cob Power Plant, Sound Shore Drive, Greenwich, Fairfield County, CT

  5. Boiler water regime

    NASA Astrophysics Data System (ADS)

    Khavanov, Pavel; Chulenyov, Anatoly

    2017-10-01

    Active development of autonomous heating the past 25 years has led to the widespread use of hot-water boilers of small capacity up to 2.5 MW. Rational use of the design of autonomous sources of heating boilers design features significantly improve their technical, economic and operational performance. This publication reviewed and analyzed a number of features of the design, operation and exploitation of boilers of small capacity, significantly affecting the efficiency and reliability of their application.

  6. Forced-flow once-through boilers. [structural design criteria/aerospace environments

    NASA Technical Reports Server (NTRS)

    Stone, J. R.; Gray, V. H.; Gutierrez, O. A.

    1975-01-01

    A compilation and review of NASA-sponsored research on boilers for use in spacecraft electrical power generation systems is presented. Emphasis is on the heat-transfer and fluid-flow problems. In addition to space applications, much of the boiler technology is applicable to terrestrial and marine uses such as vehicular power, electrical power generation, vapor generation, and heating and cooling. Related research areas are discussed such as condensation, cavitation, line and boiler dynamics, the SNAP-8 project (Mercury-Rankine cycle), and conventional terrestrial boilers (either supercritical or gravity-assisted liquid-vapor separation types). The research effort was directed at developing the technology for once-through compact boilers with high heat fluxes to generate dry vapor stably, without utilizing gravity for phase separations. A background section that discusses, tutorially, the complex aspects of the boiling process is presented. Discussions of tests on alkali metals are interspersed with those on water and other fluids on a phenomenological basis.

  7. The enrichment of natural radionuclides in oil shale-fired power plants in Estonia--the impact of new circulating fluidized bed technology.

    PubMed

    Vaasma, Taavi; Kiisk, Madis; Meriste, Tõnis; Tkaczyk, Alan Henry

    2014-03-01

    Burning oil shale to produce electricity has a dominant position in Estonia's energy sector. Around 90% of the overall electric energy production originates from the Narva Power Plants. The technology in use has been significantly renovated - two older types of pulverized fuel burning (PF) energy production units were replaced with new circulating fluidized bed (CFB) technology. Additional filter systems have been added to PF boilers to reduce emissions. Oil shale contains various amounts of natural radionuclides. These radionuclides concentrate and become enriched in different boiler ash fractions. More volatile isotopes will be partially emitted to the atmosphere via flue gases and fly ash. To our knowledge, there has been no previous study for CFB boiler systems on natural radionuclide enrichment and their atmospheric emissions. Ash samples were collected from Eesti Power Plant's CFB boiler. These samples were processed and analyzed with gamma spectrometry. Activity concentrations (Bq/kg) and enrichment factors were calculated for the (238)U ((238)U, (226)Ra, (210)Pb) and (232)Th ((232)Th, (228)Ra) family radionuclides and for (40)K in different CFB boiler ash fractions. Results from the CFB boiler ash sample analysis showed an increase in the activity concentrations and enrichment factors (up to 4.5) from the furnace toward the electrostatic precipitator block. The volatile radionuclide ((210)Pb and (40)K) activity concentrations in CFB boilers were evenly distributed in finer ash fractions. Activity balance calculations showed discrepancies between input (via oil shale) and output (via ash fractions) activities for some radionuclides ((238)U, (226)Ra, (210)Pb). This refers to a situation where the missing part of the activity (around 20% for these radionuclides) is emitted to the atmosphere. Also different behavior patterns were detected for the two Ra isotopes, (226)Ra and (228)Ra. A part of (226)Ra input activity, unlike (228)Ra, was undetectable in the solid ash fractions of the boiler. Most probably it is released to the surrounding environment. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Technology Solutions Case Study: Boiler Control Replacement for Hydronically Heated Multifamily Buildings, Cambridge, Massachusetts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2014-11-01

    The ARIES Collaborative, a U.S. Department of Energy Building America research team, partnered with NeighborWorks America affiliate Homeowners' Rehab Inc. (HRI) of Cambridge, Massachusetts, to study improvements to the central hydronic heating system in one of the nonprofit's housing developments. The heating controls in the three-building, 42-unit Columbia Cambridge Alliance for Spanish Tenants housing development were upgraded. Fuel use in the development was excessive compared to similar properties. A poorly insulated thermal envelope contributed to high energy bills, but adding wall insulation was not cost-effective or practical. The more cost-effective option was improving heating system efficiency, which faced several obstacles,more » including inflexible boiler controls and failed thermostatic radiator valves. Boiler controls were replaced with systems that offer temperature setbacks and one that controls heat based on apartment temperature in addition to outdoor temperature. Utility bill analysis shows that post-retrofit weather-normalized heating energy use was reduced by 10%-31% (average of 19%). Indoor temperature cutoff reduced boiler runtime (and therefore heating fuel consumption) by 28% in the one building in which it was implemented. Nearly all savings were obtained during night which had a lower indoor temperature cut off (68°F) than day (73° F). This implies that the outdoor reset curve was appropriately adjusted for this building for daytime operation. Nighttime setback of heating system supply water temperature had no discernable impact on boiler runtime or gas bills.« less

  9. Industrial Application Study on New-Type Mixed-Flow Fluidized Bed Bottom Ash Cooler

    NASA Astrophysics Data System (ADS)

    Zeng, B.; Lu, X. F.; Liu, H. Z.

    As a key auxiliary device of CFB boiler, the bottom ash cooler (BAC) has a direct influence on secure and economic operation of the boiler. The operating situation of domestic CFB power plant is complex and changeable with a bad coal-fired condition. The principle for designing BAC suitable for the bad coal-fired condition and high parameter CFB boilers was summarized in this paper. Meanwhile, a new-type mixed-flow fluidized bed bottom ash cooler was successfully designed on the basis of the comprehensive investigation on the existing BAC s merits and drawbacks. Using coarse/fine slag separation technology and micro-bubbling fluidization are the significant characteristics of this new BAC. This paper also puts great emphasis on its industrial test in a 460t/h CFB boiler. The results indicate that it achieves significant separation of the coarse/fine slag, an obvious cooling effect, no slag block and coking phenomenon, and continuous stable operation. Figs 7, Tabs 4 and Refs 11.

  10. Boiler for generating high quality vapor

    NASA Technical Reports Server (NTRS)

    Gray, V. H.; Marto, P. J.; Joslyn, A. W.

    1972-01-01

    Boiler supplies vapor for use in turbines by imparting a high angular velocity to the liquid annulus in heated rotating drum. Drum boiler provides a sharp interface between boiling liquid and vapor, thereby, inhibiting the formation of unwanted liquid droplets.

  11. 4. STEAM PLANT MARINE BOILERS WEST OF STEAM PLANT AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. STEAM PLANT MARINE BOILERS WEST OF STEAM PLANT AND SOUTH OF ORIGINAL STEAM PLANT BOILERS, FROM SOUTH. November 13, 1990 - Crosscut Steam Plant, North side Salt River near Mill Avenue & Washington Street, Tempe, Maricopa County, AZ

  12. 38. Photocopy of photograph. STEEL PLANT, BOILERS UNDER CONSTRUCTION IN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    38. Photocopy of photograph. STEEL PLANT, BOILERS UNDER CONSTRUCTION IN BOILER PLANT LOCATED EAST OF MAIN STEEL PLANT, 1909. (From the Bethlehem Steel Corporation collection, Seattle, WA) - Irondale Iron & Steel Plant, Port Townsend, Jefferson County, WA

  13. MUNICIPAL WASTE COMBUSTION ASSESSMENT: FOSSIL FUEL CO-FIRING

    EPA Science Inventory

    The report identifies refuse derived fuel (RDF) processing operations and various RDF types; describes such fossil fuel co-firing techniques as coal fired spreader stokers, pulverized coal wall fired boilers, pulverized coal tangentially fired boilers, and cyclone fired boilers; ...

  14. A Refrigerated Web Camera for Photogrammetric Video Measurement inside Biomass Boilers and Combustion Analysis

    PubMed Central

    Porteiro, Jacobo; Riveiro, Belén; Granada, Enrique; Armesto, Julia; Eguía, Pablo; Collazo, Joaquín

    2011-01-01

    This paper describes a prototype instrumentation system for photogrammetric measuring of bed and ash layers, as well as for flying particle detection and pursuit using a single device (CCD) web camera. The system was designed to obtain images of the combustion process in the interior of a domestic boiler. It includes a cooling system, needed because of the high temperatures in the combustion chamber of the boiler. The cooling system was designed using CFD simulations to ensure effectiveness. This method allows more complete and real-time monitoring of the combustion process taking place inside a boiler. The information gained from this system may facilitate the optimisation of boiler processes. PMID:22319349

  15. A refrigerated web camera for photogrammetric video measurement inside biomass boilers and combustion analysis.

    PubMed

    Porteiro, Jacobo; Riveiro, Belén; Granada, Enrique; Armesto, Julia; Eguía, Pablo; Collazo, Joaquín

    2011-01-01

    This paper describes a prototype instrumentation system for photogrammetric measuring of bed and ash layers, as well as for flying particle detection and pursuit using a single device (CCD) web camera. The system was designed to obtain images of the combustion process in the interior of a domestic boiler. It includes a cooling system, needed because of the high temperatures in the combustion chamber of the boiler. The cooling system was designed using CFD simulations to ensure effectiveness. This method allows more complete and real-time monitoring of the combustion process taking place inside a boiler. The information gained from this system may facilitate the optimisation of boiler processes.

  16. Boiler Briquette Coal versus Raw Coal: Part II-Energy, Greenhouse Gas, and Air Quality Implications.

    PubMed

    Zhang, Junfeng; Ge, Su; Bai, Zhipeng

    2001-04-01

    The objective of this paper is to conduct an integrated analysis of the energy, greenhouse gas, and air quality impacts of a new type of boiler briquette coal (BB-coal) in contrast to those of the raw coal from which the BB-coal was formulated (R-coal). The analysis is based on the source emissions data and other relevant data collected in the present study and employs approaches including the construction of carbon, energy, and sulfur balances. The results show that replacing R-coal with BB-coal as the fuel for boilers such as the one tested would have multiple benefits, including a 37% increase in boiler thermal efficiency, a 25% reduction in fuel demand, a 26% reduction in CO 2 emission, a 17% reduction in CO emission, a 63% reduction in SO 2 emission, a 97% reduction in fly ash and fly ash carbon emission, a 22% reduction in PM 2.5 mass emission, and a 30% reduction in total emission of five toxic hazardous air pollutant (HAP) metals contained in PM 10 . These benefits can be achieved with no changes in boiler hardware and with a relatively small amount of tradeoffs: a 30% increase in PM 10 mass emission and a 9-16% increase in fuel cost.

  17. Boiler briquette coal versus raw coal: Part II--Energy, greenhouse gas, and air quality implications.

    PubMed

    Zhang, J; Ge, S; Bai, Z

    2001-04-01

    The objective of this paper is to conduct an integrated analysis of the energy, greenhouse gas, and air quality impacts of a new type of boiler briquette coal (BB-coal) in contrast to those of the raw coal from which the BB-coal was formulated (R-coal). The analysis is based on the source emissions data and other relevant data collected in the present study and employs approaches including the construction of carbon, energy, and sulfur balances. The results show that replacing R-coal with BB-coal as the fuel for boilers such as the one tested would have multiple benefits, including a 37% increase in boiler thermal efficiency, a 25% reduction in fuel demand, a 26% reduction in CO2 emission, a 17% reduction in CO emission, a 63% reduction in SO2 emission, a 97% reduction in fly ash and fly ash carbon emission, a 22% reduction in PM2.5 mass emission, and a 30% reduction in total emission of five toxic hazardous air pollutant (HAP) metals contained in PM10. These benefits can be achieved with no changes in boiler hardware and with a relatively small amount of tradeoffs: a 30% increase in PM10 mass emission and a 9-16% increase in fuel cost.

  18. Estimation of Scale Deposition in the Water Walls of an Operating Indian Coal Fired Boiler: Predictive Modeling Approach Using Artificial Neural Networks

    NASA Astrophysics Data System (ADS)

    Kumari, Amrita; Das, Suchandan Kumar; Srivastava, Prem Kumar

    2016-04-01

    Application of computational intelligence for predicting industrial processes has been in extensive use in various industrial sectors including power sector industry. An ANN model using multi-layer perceptron philosophy has been proposed in this paper to predict the deposition behaviors of oxide scale on waterwall tubes of a coal fired boiler. The input parameters comprises of boiler water chemistry and associated operating parameters, such as, pH, alkalinity, total dissolved solids, specific conductivity, iron and dissolved oxygen concentration of the feed water and local heat flux on boiler tube. An efficient gradient based network optimization algorithm has been employed to minimize neural predictions errors. Effects of heat flux, iron content, pH and the concentrations of total dissolved solids in feed water and other operating variables on the scale deposition behavior have been studied. It has been observed that heat flux, iron content and pH of the feed water have a relatively prime influence on the rate of oxide scale deposition in water walls of an Indian boiler. Reasonably good agreement between ANN model predictions and the measured values of oxide scale deposition rate has been observed which is corroborated by the regression fit between these values.

  19. 34. (Credit JTL) Front (north side) of three water tube ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    34. (Credit JTL) Front (north side) of three water tube boilers built by the Heine Safety Boiler Co. of St. Louis, Missouri in 1917; rebuilt in 1938. Front doors opened on center boiler to show water header and inspection plugs for water tubes. Smaller doors beneath open into firebox; boilers presently equipped for gas firing. Operating pressure approx. 150 psi (saturated steam). - McNeil Street Pumping Station, McNeil Street & Cross Bayou, Shreveport, Caddo Parish, LA

  20. Contributions to the use of macrosounds for boiler decrusting

    NASA Technical Reports Server (NTRS)

    Bradeteanu, C.

    1974-01-01

    The results of an investigation indicate the following: (1) The deposition of incrustations on the heating surfaces of steam boilers can be prevented by inserting between heating surface and water an insulating layer on which the boiler incrustation will be deposited. (2) The insulating layer reduces the coefficient of heat transmission by 2%. (3) The insulating layer can be removed by macrosounds with a frequency of about 20 kHz, after any interval of boiler operation.

  1. Simulation and analysis of main steam control system based on heat transfer calculation

    NASA Astrophysics Data System (ADS)

    Huang, Zhenqun; Li, Ruyan; Feng, Zhongbao; Wang, Songhan; Li, Wenbo; Cheng, Jiwei; Jin, Yingai

    2018-05-01

    In this paper, after thermal power plant 300MW boiler was studied, mat lab was used to write calculation program about heat transfer process between the main steam and boiler flue gas and amount of water was calculated to ensure the main steam temperature keeping in target temperature. Then heat transfer calculation program was introduced into Simulink simulation platform based on control system multiple models switching and heat transfer calculation. The results show that multiple models switching control system based on heat transfer calculation not only overcome the large inertia of main stream temperature, a large hysteresis characteristic of main stream temperature, but also adapted to the boiler load changing.

  2. Research needs of the power industry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DeSollar, R.W.

    1996-12-31

    Most utilities have boilers that were designed to burn a specific fuel and, in most cases, the fuel was a high sulfur, high Btu, bituminous coal. With fuel switching many boilers are now being required to burn a fuel that is drastically different than that for which the boiler was designed. This is leading to a whole range of new problems. Fuel engineers now are more concerned with the slagging, fouling, corrosion and erosion that can take place in the boiler, and not only how the fuel burns. Utilities now look not only at the Btu of the fuel butmore » are concerned with the ash chemistry, grindability, and the ultimate analysis, especially nitrogen and oxygen that is inherent in the coal. Many utilities are not geared for and do not have the people and expertise necessary for all of the studies and evaluation that must be done. Some areas that need to be addressed by research are slagging and fouling indices for western coals and blends of eastern and western coals. Corrosion indices are needed which pertain not only to the high temperature superheater and reheat areas of the boilers, but also to the backpasses, the economizer, air heater, and especially the precipitator. The effects of chlorine in a boiler and hazardous air pollutants need to be addressed. Fuel switching has also caused precipitator problems. Work needs to be done on identifying coals that are difficult to collect as well as those coals that will not accept flue gas conditioning, and why the ash won`t condition.« less

  3. DESIGN REPORT: LOW-NOX BURNERS FOR PACKAGE BOILERS

    EPA Science Inventory

    The report describes a low-NOx burner design, presented for residual-oil-fired industrial boilers and boilers cofiring conventional fuels and nitrated hazardous wastes. The burner offers lower NOx emission levels for these applications than conventional commercial burners. The bu...

  4. 49 CFR 230.36 - Hydrostatic testing of boilers.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Appurtenances Pressure Testing of Boilers § 230.36 Hydrostatic testing of boilers. (a) Time of test. The... to any hydrostatic pressure. Hydrostatic testing required by these rules shall be conducted at 25... following any hydrostatic test where the pressure exceeds MAWP. ...

  5. 46 CFR 52.05-1 - General (modifies PW-1 through PW-54).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... BOILERS Requirements for Boilers Fabricated by Welding § 52.05-1 General (modifies PW-1 through PW-54). (a) Boilers and component parts, including piping, that are fabricated by welding shall be as indicated in PW...

  6. Engineering and Design: Adsorption Design Guide

    DTIC Science & Technology

    2001-03-01

    tested, and marked (or stamped) in accordance with the standards of the applicable Boiler and Pressure Vessel Code (ASME, 1992), and must incorporate...Boiler and Pressure Vessel Committee, Subcommittee on Pressure Vessels, 1992. ASME Boiler and Pressure Vessel Code , Section VIII, Rules for

  7. 36. REDUCTION PLANT CLOSE VIEW OF FURNACE AND BOILER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    36. REDUCTION PLANT - CLOSE VIEW OF FURNACE AND BOILER Reduction Plant furnace and boiler used to provide heat for drying the fish and fish offal, in their conversion to meal. - Hovden Cannery, 886 Cannery Row, Monterey, Monterey County, CA

  8. 46 CFR 52.05-1 - General (modifies PW-1 through PW-54).

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... BOILERS Requirements for Boilers Fabricated by Welding § 52.05-1 General (modifies PW-1 through PW-54). (a) Boilers and component parts, including piping, that are fabricated by welding shall be as indicated in PW...

  9. 46 CFR 52.05-1 - General (modifies PW-1 through PW-54).

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... BOILERS Requirements for Boilers Fabricated by Welding § 52.05-1 General (modifies PW-1 through PW-54). (a) Boilers and component parts, including piping, that are fabricated by welding shall be as indicated in PW...

  10. 46 CFR 52.05-1 - General (modifies PW-1 through PW-54).

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... BOILERS Requirements for Boilers Fabricated by Welding § 52.05-1 General (modifies PW-1 through PW-54). (a) Boilers and component parts, including piping, that are fabricated by welding shall be as indicated in PW...

  11. 46 CFR 52.05-1 - General (modifies PW-1 through PW-54).

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... BOILERS Requirements for Boilers Fabricated by Welding § 52.05-1 General (modifies PW-1 through PW-54). (a) Boilers and component parts, including piping, that are fabricated by welding shall be as indicated in PW...

  12. Emissions During Co-Firing of RDF-5 with Coal in a 22 t/h Steam Bubbling Fluidized Bed Boiler

    NASA Astrophysics Data System (ADS)

    Wan, Hou-Peng; Chen, Jia-Yuan; Juch, Ching-I.; Chang, Ying-Hsi; Lee, Hom-Ti

    The co-firing of biomass and fossil fuel in the same power plant is one of the most important issues when promoting the utilization of renewable energy in the world. Recently, the co-firing of coal together with biomass fuel, such as "densified refuse derived fuel" (d-RDF or RDF-5) or RPF (refuse paper & plastic fuel) from waste, has been considered as an environmentally sound and economical approach to both waste remediation and energy production in the world. Because of itscomplex characteristics when compared to fossil fuel, potential problems, such as combustion system stability, the corrosion of heat transfer tubes, the qualities of the ash, and the emissionof pollutants, are major concerns when co-firing the biomass fuel with fossil fuel in a traditional boiler. In this study, co-firing of coal with RDF-5 was conducted in a 22t/h bubbling fluidized bed (BFB) steam boiler to investigate the feasibility of utilizing RDF-5 as a sustainable fuels in a commercial coal-fired steam BFB boiler. The properties of the fly ash, bottom ash, and the emission of pollutants are analyzed and discussed in this study.

  13. Technical and economic feasibility of alternative fuel use in process heaters and small boilers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1980-02-01

    The technical and economic feasibility of using alternate fuels - fuels other than oil and natural gas - in combustors not regulated by the Powerplant and Industrial Fuel Use Act of 1978 (FUA) was evaluated. FUA requires coal or alternate fuel use in most large new boilers and in some existing boilers. Section 747 of FUA authorizes a study of the potential for reduced oil and gas use in combustors not subject to the act: small industrial boilers with capacities less than 100 MMBtu/hr, and process heat applications. Alternative fuel use in combustors not regulated by FUA was examined andmore » the impact of several measures to encourage the substitution of alternative fuels in these combustors was analyzed. The primary processes in which significant fuel savings can be achieved are identified. Since feedstock uses of oil and natural gas are considered raw materials, not fuels, feedstock applications are not examined in this analysis. The combustors evaluated in this study comprise approximately 45% of the fuel demand projected in 1990. These uses would account for more than 3.5 million barrels per day equivalent fuel demand in 1990.« less

  14. A cost-benefit analysis of a pellet boiler with electrostatic precipitator versus conventional biomass technology: A case study of an institutional boiler in Syracuse, New York.

    PubMed

    Levy, Jonathan I; Biton, Leiran; Hopke, Philip K; Zhang, K Max; Rector, Lisa

    2017-07-01

    Biomass facilities have received increasing attention as a strategy to increase the use of renewable fuels and decrease greenhouse gas emissions from the electric generation and heating sectors, but these facilities can potentially increase local air pollution and associated health effects. Comparing the economic costs and public health benefits of alternative biomass fuel, heating technology, and pollution control technology options provides decision-makers with the necessary information to make optimal choices in a given location. For a case study of a combined heat and power biomass facility in Syracuse, New York, we used stack testing to estimate emissions of fine particulate matter (PM 2.5 ) for both the deployed technology (staged combustion pellet boiler with an electrostatic precipitator) and a conventional alternative (wood chip stoker boiler with a multicyclone). We used the atmospheric dispersion model AERMOD to calculate the contribution of either fuel-technology configuration to ambient primary PM 2.5 in a 10km×10km region surrounding the facility, and we quantified the incremental contribution to population mortality and morbidity. We assigned economic values to health outcomes and compared the health benefits of the lower-emitting technology with the incremental costs. In total, the incremental annualized cost of the lower-emitting pellet boiler was $190,000 greater, driven by a greater cost of the pellet fuel and pollution control technology, offset in part by reduced fuel storage costs. PM 2.5 emissions were a factor of 23 lower with the pellet boiler with electrostatic precipitator, with corresponding differences in contributions to ambient primary PM 2.5 concentrations. The monetary value of the public health benefits of selecting the pellet-fired boiler technology with electrostatic precipitator was $1.7 million annually, greatly exceeding the differential costs even when accounting for uncertainties. Our analyses also showed complex spatial patterns of health benefits given non-uniform age distributions and air pollution levels. The incremental investment in a lower-emitting staged combustion pellet boiler with an electrostatic precipitator was well justified by the population health improvements over the conventional wood chip technology with a multicyclone, even given the focus on only primary PM 2.5 within a small spatial domain. Our analytical framework could be generalized to other settings to inform optimal strategies for proposed new facilities or populations. Copyright © 2017. Published by Elsevier Inc.

  15. Temporal trends and spatial variation characteristics of primary air pollutants emissions from coal-fired industrial boilers in Beijing, China.

    PubMed

    Xue, Yifeng; Tian, Hezhong; Yan, Jing; Zhou, Zhen; Wang, Junling; Nie, Lei; Pan, Tao; Zhou, Junrui; Hua, Shenbing; Wang, Yong; Wu, Xiaoqing

    2016-06-01

    Coal-fired combustion is recognized as a significant anthropogenic source of atmospheric compounds in Beijing, causing heavy air pollution events and associated deterioration in visibility. Obtaining an accurate understanding of the temporal trends and spatial variation characteristics of emissions from coal-fired industrial combustion is essential for predicting air quality changes and evaluating the effectiveness of current control measures. In this study, an integrated emission inventory of primary air pollutants emitted from coal-fired industrial boilers in Beijing is developed for the period of 2007-2013 using a technology-based approach. Future emission trends are projected through 2030 based on current energy-related and emission control policies. Our analysis shows that there is a general downward trend in primary air pollutants emissions because of the implementation of stricter local emission standards and the promotion by the Beijing municipal government of converting from coal-fired industrial boilers to gas-fired boilers. However, the ratio of coal consumed by industrial boilers to total coal consumption has been increasing, raising concerns about the further improvement of air quality in Beijing. Our estimates indicate that the total emissions of PM10, PM2.5, SO2, NOx, CO and VOCs from coal-fired industrial boilers in Beijing in 2013 are approximately 19,242 t, 13,345 t, 26,615 t, 22,965 t, 63,779 t and 1406 t, respectively. Under the current environmental policies and relevant energy savings and emission control plans, it may be possible to reduce NOx and other air pollutant emissions by 94% and 90% by 2030, respectively, if advanced flue gas purification technologies are implemented and coal is replaced with natural gas in the majority of existing boilers. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Specimen Examinations for Merchant Marine Engineer Licenses (2nd and 3rd Assistant).

    DTIC Science & Technology

    1978-02-01

    blue color with evidence of overheating have probably been operated with A. excessive speed. B. improper warm - up . C. extreme misalignment. D. inadequate...the boiler has been blown down or chemicals added. C. when the boiler has been refilled with make- up feed. D. from the highest point in the feed system...An important consideration in the prevention of carry-over in a marine boiler is to A. properly treat the boiler water with hydrazine, B. control the

  17. Analysis of results obtained using the automatic chemical control of the quality of the water heat carrier in the drum boiler of the Ivanovo CHP-3 power plant

    NASA Astrophysics Data System (ADS)

    Larin, A. B.; Kolegov, A. V.

    2012-10-01

    Results of industrial tests of the new method used for the automatic chemical control of the quality of boiler water of the drum-type power boiler ( P d = 13.8 MPa) are described. The possibility of using an H-cationite column for measuring the electric conductivity of an H-cationized sample of boiler water over a long period of time is shown.

  18. 36. VIEW OF SOUTH END OF EAST BOILER ROOM LOOKING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    36. VIEW OF SOUTH END OF EAST BOILER ROOM LOOKING SOUTHWEST. THE CYLINDRICAL TANKS IN THE FOREGROUND CONTAIN AN ION-EXCHANGE RESIN FOR REMOVING CALCIUM FROM THE BOILER FEED TO REDUCE WATER "HARDNESS". THE SHALLOW TANK IN THE RIGHT BACKGROUND IS A DIATOMACEOUS EARTH FILTER TO REMOVE PARTICULATE MATTER FROM THE BOILER FEED. THE ION-EXCHANGE WATER SOFTENING SYSTEM WAS INSTALLED IN 1977. - New York, New Haven & Hartford Railroad, Cos Cob Power Plant, Sound Shore Drive, Greenwich, Fairfield County, CT

  19. 16. View into interior steam spaces of boiler above fireboxes ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    16. View into interior steam spaces of boiler above fireboxes through manhole (see photo VT-14-16 for manhole location). Tops-or crown sheets--of fireboxes show below. Vertical and inclined bars are stays used to hold boiler together and reinforce flat plates under pressure. Note water level used in boilers indicated by scale encrustation on stays. (Threaded stud in extreme foreground belongs to manhole cover opened for purposed of photography.) - Ferry TICONDEROGA, Route 7, Shelburne, Chittenden County, VT

  20. New configurations of a heat recovery absorption heat pump integrated with a natural gas boiler for boiler efficiency improvement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qu, Ming; Abdelaziz, Omar; Yin, Hongxi

    2014-11-01

    Conventional natural gas-fired boilers exhaust flue gas direct to the atmosphere at 150 200 C, which, at such temperatures, contains large amount of energy and results in relatively low thermal efficiency ranging from 70% to 80%. Although condensing boilers for recovering the heat in the flue gas have been developed over the past 40 years, their present market share is still less than 25%. The major reason for this relatively slow acceptance is the limited improvement in the thermal efficiency of condensing boilers. In the condensing boiler, the temperature of the hot water return at the range of 50 60more » C, which is used to cool the flue gas, is very close to the dew point of the water vapor in the flue gas. Therefore, the latent heat, the majority of the waste heat in the flue gas, which is contained in the water vapor, cannot be recovered. This paper presents a new approach to improve boiler thermal efficiency by integrating absorption heat pumps with natural gas boilers for waste heat recovery (HRAHP). Three configurations of HRAHPs are introduced and discussed. The three configurations are modeled in detail to illustrate the significant thermal efficiency improvement they attain. Further, for conceptual proof and validation, an existing hot water-driven absorption chiller is operated as a heat pump at operating conditions similar to one of the devised configurations. An overall system performance and economic analysis are provided for decision-making and as evidence of the potential benefits. These three configurations of HRAHP provide a pathway to achieving realistic high-efficiency natural gas boilers for applications with process fluid return temperatures higher than or close to the dew point of the water vapor in the flue gas.« less

  1. 14. Interior, boiler house, at elev. 42'8' looking west at ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    14. Interior, boiler house, at elev. 42'-8' looking west at distribution headers and coal and oil burners of retired 300 lb. boilers #11, 10, and 9. - Manchester Street Generating Station, Manchester Street Station, 460 Eddy Street, Providence, Providence County, RI

  2. APPLICATION OF REBURNING TO COAL-FIRED INDUSTRIAL BOILERS IN TAIWAN

    EPA Science Inventory

    The paper gives an overview of the characteristics of coal-fired industrial boilers in Taiwan and projections of the cost and performance data for retrofitting several boilers with reburning. The impacts of reburning fuel type on the reburning system design and cost effectivenes...

  3. Explosion in boiler closes Arkansas utility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1993-08-23

    A major boiler explosion Aug. 11 that seriously injured one worker at the Independence Unit 2 coal-fired powerplant in Newark, Ark., caused extensive damage that will keep the plant closed for several months. The plant is owned by Arkansas Power Light Co., Little Rock. Officials are still trying to determine cause and are assessing damage, though they expect the boiler can be repaired. Etienne Senac, plant manager, says the explosion [open quotes]puffed out[close quotes] but did not rupture the 271-ft-tall boiler and also buckled several buck stays, which hold the boiler to a steel superstructure. The accident took place atmore » 8:30 a.m. as the 842-Mw unit was operating close to full capacity. Senac says the concussion knocked down workers standing 50 ft from the boiler. The explosion pushed ash and molten material out of the bottom of the unit, causing a small fire. One contract worker was seriously burned and hospitalized. Four AP L workers received minor burns.« less

  4. New controls spark boiler efficiency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Engels, T.

    1993-09-01

    Monsanto's NutraSweet plant in University Park, IL, produces aspartame, the patented NutraSweet artificial sweetener product. Until recently, boiler control was managed by a '60s-era Fireye jackshaft system in which air and natural gas were mechanically linked with an offset to compensate for oxygen trim. The interlocking devices on the Fireye system were becoming obsolete, and the boiler needed a new front end retrofitted for low emissions. In order to improve boiler control efficiency, we decided to modernize and automate the entire boiler control system. We replaced the original jackshaft system, and installed a Gordon-Piet burner system, including gas valves, airmore » dampers, blowers, and burner. The upgrade challenges included developing a control strategy and selecting and implementing a process control system. Since our plant has standardized on the PROVOX process management information system from Fisher Controls (now Fisher-Rosemount Systems) to support most of our process, it was a natural and logical choice for boiler controls as well. 2 figs.« less

  5. Investigations on the Behavior of HVOF and Cold Sprayed Ni-20Cr Coating on T22 Boiler Steel in Actual Boiler Environment

    NASA Astrophysics Data System (ADS)

    Bala, Niraj; Singh, Harpreet; Prakash, Satya; Karthikeyan, J.

    2012-01-01

    High temperature corrosion accompanied by erosion is a severe problem, which may result in premature failure of the boiler tubes. One countermeasure to overcome this problem is the use of thermal spray protective coatings. In the current investigation high velocity oxy-fuel (HVOF) and cold spray processes have been used to deposit commercial Ni-20Cr powder on T22 boiler steel. To evaluate the performance of the coatings in actual conditions the bare as well as the coated steels were subjected to cyclic exposures, in the superheater zone of a coal fired boiler for 15 cycles. The weight change and thickness loss data were used to establish kinetics of the erosion-corrosion. X-ray diffraction, surface and cross-sectional field emission scanning electron microscope/energy dispersive spectroscopy (FE-SEM/EDS) and x-ray mapping techniques were used to analyse the as-sprayed and corroded specimens. The HVOF sprayed coating performed better than its cold sprayed counterpart in actual boiler environment.

  6. Improved NOx emissions and combustion characteristics for a retrofitted down-fired 300-MWe utility boiler.

    PubMed

    Li, Zhengqi; Ren, Feng; Chen, Zhichao; Liu, Guangkui; Xu, Zhenxing

    2010-05-15

    A new technique combining high boiler efficiency and low-NO(x) emissions was employed in a 300MWe down-fired boiler as an economical means to reduce NO(x) emissions in down-fired boilers burning low-volatile coals. Experiments were conducted on this boiler after the retrofit with measurements taken of gas temperature distributions along the primary air and coal mixture flows and in the furnace, furnace temperatures along the main axis and gas concentrations such as O(2), CO and NO(x) in the near-wall region. Data were compared with those obtained before the retrofit and verified that by applying the combined technique, gas temperature distributions in the furnace become more reasonable. Peak temperatures were lowered from the upper furnace to the lower furnace and flame stability was improved. Despite burning low-volatile coals, NO(x) emissions can be lowered by as much as 50% without increasing the levels of unburnt carbon in fly ash and reducing boiler thermal efficiency.

  7. Boiler MACT Technical Assistance (Fact Sheet)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    2012-03-01

    Fact sheet describing the changes to Environmental Protection Act process standards. The DOE will offer technical assistance to ensure that major sources burning coal and oil have information on cost-effective, clean energy strategies for compliance, and to promote cleaner, more efficient boiler burning to cut harmful pollution and reduce operational costs. The U.S. Environmental Protection Agency (EPA) is expected to finalize the reconsideration process for its Clean Air Act pollution standards National Emissions Standards for Hazardous Air Pollutants for Major Sources: Industrial, Commercial, and Institutional Boilers and Process Heaters (known as Boiler Maximum Achievable Control Technology (MACT)), in Spring 2012.more » This rule applies to large and small boilers in a wide range of industrial facilities and institutions. The U.S. Department of Energy (DOE) will offer technical assistance to ensure that major sources burning coal or oil have information on cost-effective clean energy strategies for compliance, including combined heat and power, and to promote cleaner, more efficient boilers to cut harmful pollution and reduce operational costs.« less

  8. Toxic trace elements in solid airborne particles and ecological risk assessment in the vicinity of local boiler house plants

    NASA Astrophysics Data System (ADS)

    Talovskaya, Anna V.; Osipova, Nina A.; Yazikov, Egor G.; Shakhova, Tatyana S.

    2017-11-01

    The article deals with assessment of anthropogenic pollution in vicinity of local boilers using the data on microelement composition of solid airborne particles deposited in snow. The anthropogenic feature of elevated accumulation levels of solid airborne particles deposited in snow in the vicinity of coal-fired boiler house is revealed in elevated concentrations (3-25 higher than background) of Cd, Sb, Mo, Pb, Sr, Ba, Ni, Mo, Zn and Co. In the vicinity oil-fired boiler house the specific elements as parts of solid airborne particles deposited in snow are V, Ni and Sb, as their content exceeds the background from 3 to 8 times. It is determined that the maximum shares in non-carcinogenic human health risk from chronic inhalation of trace elements to the human body in the vicinity of coal-fired boiler house belong to Al, Mn, Cu, Ba, Co, Pb, whereas in the vicinity of oil-fired boiler house - Al, Mn, Cu, Ni, V.

  9. Sensing system for detection and control of deposition on pendant tubes in recovery and power boilers

    DOEpatents

    Kychakoff, George; Afromowitz, Martin A; Hugle, Richard E

    2005-06-21

    A system for detection and control of deposition on pendant tubes in recovery and power boilers includes one or more deposit monitoring sensors operating in infrared regions and about 4 or 8.7 microns and directly producing images of the interior of the boiler. An image pre-processing circuit (95) in which a 2-D image formed by the video data input is captured, and includes a low pass filter for performing noise filtering of said video input. An image segmentation module (105) for separating the image of the recovery boiler interior into background, pendant tubes, and deposition. An image-understanding unit (115) matches derived regions to a 3-D model of said boiler. It derives a 3-D structure the deposition on pendant tubes in the boiler and provides the information about deposits to the plant distributed control system (130) for more efficient operation of the plant pendant tube cleaning and operating systems.

  10. 46 CFR 109.555 - Propulsion boilers.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Propulsion boilers. 109.555 Section 109.555 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS Miscellaneous § 109.555 Propulsion boilers. The master or person in charge and the engineer in charge shall...

  11. 46 CFR 109.555 - Propulsion boilers.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Propulsion boilers. 109.555 Section 109.555 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS Miscellaneous § 109.555 Propulsion boilers. The master or person in charge and the engineer in charge shall...

  12. 46 CFR 109.555 - Propulsion boilers.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Propulsion boilers. 109.555 Section 109.555 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS Miscellaneous § 109.555 Propulsion boilers. The master or person in charge and the engineer in charge shall...

  13. 46 CFR 109.555 - Propulsion boilers.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Propulsion boilers. 109.555 Section 109.555 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS Miscellaneous § 109.555 Propulsion boilers. The master or person in charge and the engineer in charge shall...

  14. 46 CFR 109.555 - Propulsion boilers.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Propulsion boilers. 109.555 Section 109.555 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS Miscellaneous § 109.555 Propulsion boilers. The master or person in charge and the engineer in charge shall...

  15. 29 CFR 1915.162 - Ship's boilers.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... dead boiler with the live system or systems shall be secured, blanked, and tagged indicating that... and shutoff valves connecting the dead boiler with the live system or systems shall be secured, locked, and tagged. (2) Drain connections to atmosphere on all of the dead interconnecting systems shall be...

  16. 29 CFR 1915.162 - Ship's boilers.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... dead boiler with the live system or systems shall be secured, blanked, and tagged indicating that... and shutoff valves connecting the dead boiler with the live system or systems shall be secured, locked, and tagged. (2) Drain connections to atmosphere on all of the dead interconnecting systems shall be...

  17. 75 FR 12168 - Approval and Promulgation of Air Quality Implementation Plans; Delaware; Control of Nitrogen...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-15

    ... Boilers and Process Heaters at Petroleum Refineries AGENCY: Environmental Protection Agency (EPA). ACTION... from Industrial Boilers and Process Heaters at Petroleum Refineries to Delaware's Regulation No. 1142... Nitrogen Oxide Emissions from Industrial Boilers and Process Heaters at Petroleum Refineries. The...

  18. VALIDATION OF MERCURY CEMS WHEN COFIRING BIOMASS AT MADISON ELECTRIC'S BLOUNT STATION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dennis L. Laudal; Jeffrey S. Thompson

    2000-09-30

    The state of Wisconsin has been concerned about mercury deposition into its lakes and streams and has been evaluating strategies to reduce mercury emissions. As part of this effort, the Blount Station, owned and operated by Madison Gas and Electric Company (MGE), has undergone a project to evaluate the effects and potential mercury emissions reduction of cofiring preconsumer waste. MGE owns and operates the Blount Generating Station located in central Madison, Wisconsin. At present, Blount operates with nine boilers and six turbine generators. The two largest boilers at Blount produce 400,000 pounds of steam per hour at 950 F andmore » 1250 psi. These larger boilers, MGE's Boiler Nos. 8 and 9, have the capability of cofiring both paper and plastic. MGE's Blount Generating Station was one of the first electric generating stations in the United States to retrofit its existing steam boilers to successfully burn refuse-derived fuel and other alternate fuels including waste paper and wood. It is the No. 9 boiler that was the focus of this project to determine the effect of cofiring PDF (plastic- and paper-derived fuel) on speciated mercury emissions. The project was laid out to compare four different fuel combinations: (1) coal feed only, (2) coal with plastic, (3) coal with paper, and (4) coal with paper and plastic. The design was to run the boiler for 2 days at each condition, thus allowing four samples to be taken at each condition. This plan was aimed at getting at least three representative samples at each condition and allowed for difficulties in sampling and boiler operation. The following objectives were accomplished as part of the project to determine the effects of cofiring PDF on mercury emissions and speciation at MGE Blount Station: Successfully completed all of the mercury sampling for each of the four boiler/PDF conditions using the Ontario Hydro (OH) mercury speciation method; Determined mercury concentrations at the stack location using mercury continuous emission monitors (CEMs) for each of the four boiler/PDF conditions; Calculated the overall mercury mass balance for each of the runs; Determined chlorine concentrations at the stack location using EPA Method 26A for each of the four boiler/PDF conditions; and Calculated speciated mercury flow to determine removal and/or transformations before its exiting the unit at the stack for each of the four boiler/PDF conditions.« less

  19. Building America Case Study: Boiler Control Replacement for Hydronically Heated Multifamily Buildings, Cambridge, Massachusetts (Fact Sheet)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    2014-11-01

    The ARIES Collaborative, a U.S. Department of Energy Building America research team, partnered with NeighborWorks America affiliate Homeowners' Rehab Inc. (HRI) of Cambridge, Massachusetts, to study improvements to the central hydronic heating system in one of the nonprofit's housing developments. The heating controls in the three-building, 42-unit Columbia Cambridge Alliance for Spanish Tenants housing development were upgraded. Fuel use in the development was excessive compared to similar properties. A poorly insulated thermal envelope contributed to high energy bills, but adding wall insulation was not cost-effective or practical. The more cost-effective option was improving heating system efficiency. Efficient operation of themore » heating system faced several obstacles, including inflexible boiler controls and failed thermostatic radiator valves. Boiler controls were replaced with systems that offer temperature setbacks and one that controls heat based on apartment temperature in addition to outdoor temperature. Utility bill analysis shows that post-retrofit weather-normalized heating energy use was reduced by 10%-31% (average of 19%). Indoor temperature cutoff reduced boiler runtime (and therefore heating fuel consumption) by 28% in the one building in which it was implemented. Nearly all savings were obtained during night which had a lower indoor temperature cut off (68 degrees F) than day (73 degrees F). This implies that the outdoor reset curve was appropriately adjusted for this building for daytime operation. Nighttime setback of heating system supply water temperature had no discernable impact on boiler runtime or gas bills.« less

  20. Effects of application of mill-generated primary sludge and boiler ash on loblolly pine survival and growth

    Treesearch

    Emily J. Goodwin; Andrew M. Burrow

    2006-01-01

    Use of Kraft primary sludge and boiler ash in forest production systems holds promise as a cost-effective alternative to landfilling. From a soil quality perspective, particularly in coarse-textured sandy soils, increases in organic matter content from inputs of sludge/ash may improve soil chemical, biological, and physical properties. The objective of this study was...

  1. Radiation from Large Gas Volumes and Heat Exchange in Steam Boiler Furnaces

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Makarov, A. N., E-mail: tgtu-kafedra-ese@mail.ru

    2015-09-15

    Radiation from large cylindrical gas volumes is studied as a means of simulating the flare in steam boiler furnaces. Calculations of heat exchange in a furnace by the zonal method and by simulation of the flare with cylindrical gas volumes are described. The latter method is more accurate and yields more reliable information on heat transfer processes taking place in furnaces.

  2. Design and study of water supply system for supercritical unit boiler in thermal power station

    NASA Astrophysics Data System (ADS)

    Du, Zenghui

    2018-04-01

    In order to design and optimize the boiler feed water system of supercritical unit, the establishment of a highly accurate controlled object model and its dynamic characteristics are prerequisites for developing a perfect thermal control system. In this paper, the method of mechanism modeling often leads to large systematic errors. Aiming at the information contained in the historical operation data of the boiler typical thermal system, the modern intelligent identification method to establish a high-precision quantitative model is used. This method avoids the difficulties caused by the disturbance experiment modeling for the actual system in the field, and provides a strong reference for the design and optimization of the thermal automation control system in the thermal power plant.

  3. An evaluation of continuous emissions monitoring systems for improving industrial boiler efficiency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eckerlin, H.M.; Hall, R.C.

    1996-12-31

    An experimental evaluation of currently available continuous emissions monitoring systems has been conducted at an industrial boiler facility. The analyzers used in the study represented a range of sensors and sampling systems. The performance of three systems was monitored and compared over a six-month period. Careful records were also kept on installation, calibration and maintenance requirements. Research results suggest that (at present) the close-coupled extractive systems using a zirconium oxide sensor (for O{sub 2}) and a catalytic combustibles sensor (for CO/combustibles) offer the most reliable, trouble-free performance. The project also provided valuable insights on a variety of issues relating tomore » the continuous monitoring of emissions from industrial boilers.« less

  4. An evaluation of continuous emissions monitoring systems for improving industrial boiler efficiency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eckerlin, H.M.; Hall, R.C.

    1996-05-01

    An experimental evaluation of currently available continuous emissions monitoring systems has been conducted at an industrial boiler facility. The analyzers used in the study represented a range of sensors and sampling systems. The performance of three systems was monitored and compared over a six-month period. Careful records were also kept on installation, calibration and maintenance requirements. Research results suggest that (at present) the close-coupled extractive systems using a zirconium oxide sensor (for O{sub 2}) and a catalytic combustibles sensor (for CO/combustibles) offer the most reliable, trouble-free performance. The project also provided valuable insights on a variety of issues relating tomore » the continuous monitoring of emissions from industrial boilers.« less

  5. 12. Interior, boiler house, at elev. 55' looking west at ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. Interior, boiler house, at elev. 55' looking west at retired 300 lb. boilers #11, 10, and 9 with pulverized coal storage hoppers on upper left and rock coal storage bunkers on upper right. - Manchester Street Generating Station, Manchester Street Station, 460 Eddy Street, Providence, Providence County, RI

  6. 46 CFR 109.205 - Inspection of boilers and machinery.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Inspection of boilers and machinery. 109.205 Section 109.205 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS Tests, Drills, and Inspections § 109.205 Inspection of boilers and machinery. The chief engineer...

  7. 46 CFR 109.205 - Inspection of boilers and machinery.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Inspection of boilers and machinery. 109.205 Section 109.205 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS Tests, Drills, and Inspections § 109.205 Inspection of boilers and machinery. The chief engineer...

  8. 46 CFR 109.205 - Inspection of boilers and machinery.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Inspection of boilers and machinery. 109.205 Section 109.205 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS Tests, Drills, and Inspections § 109.205 Inspection of boilers and machinery. The chief engineer...

  9. 46 CFR 109.205 - Inspection of boilers and machinery.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Inspection of boilers and machinery. 109.205 Section 109.205 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS Tests, Drills, and Inspections § 109.205 Inspection of boilers and machinery. The chief engineer...

  10. 46 CFR 109.205 - Inspection of boilers and machinery.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Inspection of boilers and machinery. 109.205 Section 109.205 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS Tests, Drills, and Inspections § 109.205 Inspection of boilers and machinery. The chief engineer...

  11. 49 CFR 230.35 - Pressure testing.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Pressure Testing of Boilers § 230.35 Pressure testing. The temperature of the steam locomotive boiler shall be raised to at least 70 deg. F any time hydrostatic pressure is applied to the boiler. ... 49 Transportation 4 2010-10-01 2010-10-01 false Pressure testing. 230.35 Section 230.35...

  12. 29 CFR 1915.162 - Ship's boilers.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... dead boiler with the live system or systems shall be secured, blanked, and then locked or tagged, in... the dead boiler with the live system or systems shall be secured, and then locked or tagged, in accordance with § 1915.89. (2) Drain connections to atmosphere on all of the dead interconnecting systems...

  13. 29 CFR 1915.162 - Ship's boilers.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... dead boiler with the live system or systems shall be secured, blanked, and then locked or tagged, in... the dead boiler with the live system or systems shall be secured, and then locked or tagged, in accordance with § 1915.89. (2) Drain connections to atmosphere on all of the dead interconnecting systems...

  14. 38. ELEPHANT BOILERS 1905: Photocopy of April 1905 photograph ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    38. ELEPHANT BOILERS - 1905: Photocopy of April 1905 photograph showing elephant boilers along the west wall of the Washington and Mason Street powerhouse and car barn. View looking west on first floor of building. - San Francisco Cable Railway, Washington & Mason Streets, San Francisco, San Francisco County, CA

  15. 29 CFR 1915.162 - Ship's boilers.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... dead boiler with the live system or systems shall be secured, blanked, and then locked or tagged, in... the dead boiler with the live system or systems shall be secured, and then locked or tagged, in accordance with § 1915.89. (2) Drain connections to atmosphere on all of the dead interconnecting systems...

  16. 49 CFR 230.57 - Injectors and feedwater pumps.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Appurtenances Injectors, Feedwater Pumps, and Flue Plugs § 230.57 Injectors and feedwater pumps. (a) Water... water to the boiler, at least one of which is a live steam injector. (b) Maintenance and testing... delivering water to the boiler. Boiler checks, delivery pipes, feed water pipes, tank hose and tank valves...

  17. 46 CFR 63.25-3 - Electric hot water supply boilers.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... boilers that meet the requirements of UL 174 may have temperature-pressure relief valves that meet the... having a current rating of more than 48 amperes and employing resistance type heating elements must have... supply boiler employing a resistance type immersion electric heating element, must not exceed 48 amperes...

  18. 46 CFR 63.25-3 - Electric hot water supply boilers.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... boilers that meet the requirements of UL 174 may have temperature-pressure relief valves that meet the... having a current rating of more than 48 amperes and employing resistance type heating elements must have... supply boiler employing a resistance type immersion electric heating element, must not exceed 48 amperes...

  19. 46 CFR 63.25-3 - Electric hot water supply boilers.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... boilers that meet the requirements of UL 174 may have temperature-pressure relief valves that meet the... having a current rating of more than 48 amperes and employing resistance type heating elements must have... supply boiler employing a resistance type immersion electric heating element, must not exceed 48 amperes...

  20. 40 CFR 266.104 - Standards to control organic emissions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... DRE trial burn. (5) Low risk waste. Owners and operators of boilers or industrial furnaces that burn... HAZARDOUS WASTE MANAGEMENT FACILITIES Hazardous Waste Burned in Boilers and Industrial Furnaces § 266.104...) of this section, a boiler or industrial furnace burning hazardous waste must achieve a destruction...

  1. 40 CFR 266.104 - Standards to control organic emissions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... DRE trial burn. (5) Low risk waste. Owners and operators of boilers or industrial furnaces that burn... HAZARDOUS WASTE MANAGEMENT FACILITIES Hazardous Waste Burned in Boilers and Industrial Furnaces § 266.104...) of this section, a boiler or industrial furnace burning hazardous waste must achieve a destruction...

  2. 75 FR 31711 - Approval and Promulgation of Air Quality Implementation Plans; Delaware; Control of Nitrogen...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-04

    ... Boilers and Process Heaters at Petroleum Refineries AGENCY: Environmental Protection Agency (EPA). ACTION... controlling nitrogen oxide (NOx) emissions from industrial boilers. This action is being taken under the Clean...--Control of Nitrogen Oxide Emissions from Industrial Boilers and Process Heaters at Petroleum Refineries in...

  3. 78 FR 38713 - Agency Information Collection Activities; Proposed Collection; Comment Request; Information...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-27

    ... Activities; Proposed Collection; Comment Request; Information Requirements for Boilers and Industrial... Boilers and Industrial Furnaces (EPA ICR No. 1361.16, OMB Control No. 2050-0073) to the Office of... boilers, incinerators, and industrial furnaces (BIFs) under 40 CFR parts 63, 264, 265, 266 and 270. This...

  4. Millwright Apprenticeship. Related Training Modules. 7.1-7.9 Boilers.

    ERIC Educational Resources Information Center

    Lane Community Coll., Eugene, OR.

    This packet, part of the instructional materials for the Oregon apprenticeship program for millwright training, contains nine modules covering boilers. The modules provide information on the following topics: fire and water tube types of boilers, construction, fittings, operation, cleaning, heat recovery systems, instruments and controls, and…

  5. 75 FR 19296 - Energy Conservation Program: Test Procedures and Energy Conservation Standards for Residential...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-14

    ... Procedures and Energy Conservation Standards for Residential Furnaces and Boilers AGENCY: Office of Energy... supplemental notice of proposed rulemaking (SNOPR) to amend the test procedures for furnaces and boilers, and... Procedures for Residential Furnaces and Boilers'' or ``NOPM for Energy Conservation Standards for Residential...

  6. 77 FR 3211 - Approval and Promulgation of Air Quality Implementation Plans; Delaware; Amendments to the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-23

    ... Emissions From Industrial Boilers and Process Heaters at Petroleum Refineries AGENCY: Environmental... that establishes controls for nitrogen oxides (NO X ) emissions from industrial boilers and process... carbon monoxide (CO) boiler at the Delaware City Refinery and providing for a facility-wide NOx emission...

  7. 16. Boiler room, view looking east showing three, four pass ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    16. Boiler room, view looking east showing three, four pass horizontal Cleaver Brooks Package Boilers, 1-150 H.P. and 2-200 H.P., 6900 lbs/hour and 5175 lbs/hour, 200 PSI - East Boston Pumping Station, Chelsea Street at Chelsea Creek, Boston, Suffolk County, MA

  8. 77 FR 28489 - Approval and Promulgation of Air Quality Implementation Plans; Delaware; Amendments to the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-15

    ... Emissions From Industrial Boilers and Process Heaters at Petroleum Refineries AGENCY: Environmental... controls for nitrogen oxides (NO X ) emissions from industrial boilers and process heaters at petroleum... industrial boilers and process heaters at petroleum refineries. The formal SIP revision was submitted by...

  9. 13. VIEW LOOKING NORTHEAST FROM ROOF OF WEST BOILER ROOM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    13. VIEW LOOKING NORTHEAST FROM ROOF OF WEST BOILER ROOM AT SIROCCO DUST COLLECTOR WHICH FORMED PART OF THE ORIGINAL POLLUTION CONTROL SYSTEM FOR BOILERS 900 AND 901 INSTALLED IN 1926-1928. - New York, New Haven & Hartford Railroad, Cos Cob Power Plant, Sound Shore Drive, Greenwich, Fairfield County, CT

  10. 76 FR 58114 - Approval and Promulgation of Air Quality Implementation Plans; Pennsylvania; Control of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-20

    ... the Operation of Outdoor Wood-Fired Boilers AGENCY: Environmental Protection Agency (EPA). ACTION... the operation of outdoor wood-fired boilers (OWBs). EPA is approving this revision to reduce particular matter emissions from the operation of outdoor wood-fired boilers in accordance with the...

  11. 76. General view looking east showing Rust Co. boiler stacks ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    76. General view looking east showing Rust Co. boiler stacks at left, Babcock & Wilcox type boiler stacks at right, Dovel horizontal gas washer in foreground, and No. 1 Furnace in distance. - Sloss-Sheffield Steel & Iron, First Avenue North Viaduct at Thirty-second Street, Birmingham, Jefferson County, AL

  12. 49 CFR 230.23 - Responsibility for general construction and safe working pressure.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... MAINTENANCE STANDARDS Boilers and Appurtenances § 230.23 Responsibility for general construction and safe... construction of the steam locomotive boilers under their control. The steam locomotive owner shall establish the safe working pressure for each steam locomotive boiler, after giving full consideration to the...

  13. 75 FR 45080 - Revisions to the California State Implementation Plan

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-02

    ... revisions concern oxides of nitrogen (NO X ) emissions from boilers, steam generators and process heaters... 1--Submitted Rule Local agency Rule No. Rule title Adopted Submitted SJVUAPCD 4308 Boilers, Steam... regulations that control NO X emissions. Rule 4308 limits NO X and CO emissions from boilers, steam generators...

  14. 14. Elevation of boiler backhead showing (left to right at ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    14. Elevation of boiler backhead showing (left to right at top) steam pressure gauge, sight glass (indicates water level in boiler), manhole (for maintenance access to steam space), and try-cocks (used to determine water level if sight glass is inoperative). Below the firedoors lie air plenums which supply air from blower to firegrates; plenum door at lower left has been removed for photography. Each boiler was built by W. & A. Fletcher Co. to operate at 50 p.s.i. - Steamboat TICONDEROGA, Shelburne Museum Route 7, Shelburne, Chittenden County, VT

  15. Industrial Research of Condensing Unit for Natural Gas Boiler House

    NASA Astrophysics Data System (ADS)

    Ziemele, Jelena; Blumberga, Dagnija; Talcis, Normunds; Laicane, Ilze

    2012-12-01

    In the course of work industrial research was carried out at the boiler plant A/S "Imanta" where a 10MW passive condensing economizer working on natural gas was installed after the 116MW water boiler. The work describes the design of the condensing economizer and wiring diagram. During the industrial experiment, the following measurements were made: the temperature of water before and after the economizer; the ambient temperature; the quantity of water passing through the economizer; heat, produced by the economizer and water boilers. The work summarizes the data from 2010-2011.

  16. Hybrid intelligent monironing systems for thermal power plant trips

    NASA Astrophysics Data System (ADS)

    Barsoum, Nader; Ismail, Firas Basim

    2012-11-01

    Steam boiler is one of the main equipment in thermal power plants. If the steam boiler trips it may lead to entire shutdown of the plant, which is economically burdensome. Early boiler trips monitoring is crucial to maintain normal and safe operational conditions. In the present work two artificial intelligent monitoring systems specialized in boiler trips have been proposed and coded within the MATLAB environment. The training and validation of the two systems has been performed using real operational data captured from the plant control system of selected power plant. An integrated plant data preparation framework for seven boiler trips with related operational variables has been proposed for IMSs data analysis. The first IMS represents the use of pure Artificial Neural Network system for boiler trip detection. All seven boiler trips under consideration have been detected by IMSs before or at the same time of the plant control system. The second IMS represents the use of Genetic Algorithms and Artificial Neural Networks as a hybrid intelligent system. A slightly lower root mean square error was observed in the second system which reveals that the hybrid intelligent system performed better than the pure neural network system. Also, the optimal selection of the most influencing variables performed successfully by the hybrid intelligent system.

  17. The use of laser-induced plasma spectroscopy technique for the characterization of boiler tubes

    NASA Astrophysics Data System (ADS)

    Nicolas, G.; Mateo, M. P.; Yañez, A.

    2007-12-01

    The present work focuses on the characterization of boiler tube walls using laser-induced plasma spectroscopy technique with visual inspection by optical and scanning electron microscopy of the cross-sections of these tubes. In a watertube boiler, water runs through tubes that are surrounded by a heating source. As a result, the water is heated to very high temperatures, causing accumulation of deposits on the inside surfaces of the tubes. These deposits play an important role in the efficiency of the boiler tube because they produce a reduction of the boiler heat rate and an increase in the number of tube failures. The objectives are to determine the thickness and arrangement of deposits located on the highest heat area of the boiler and compare them with tube parts where the heat flux is lower. The major deposits found were copper and magnetite. These deposits come mainly from the boiler feedwater and from the reaction between iron and water, and they do not form on the tube walls at a uniform rate over time. Their amount depends on the areas where they are collected. A Nd:YAG laser operating at 355 nm has been used to perform laser-induced plasma spectra and depth profiles of the deposits.

  18. Non-OEM experience with NOx reduction applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Birchett, K.S.; Chung, L.; Caldwell, R.E.

    1996-01-01

    Heightened global environmental awareness and mandated deadlines for emission compliance required by the Clean Air Act, demand operators to increase controls on boiler emissions. For decades, the utility boiler industry has been dominated by the large OEM`s. In the past, boiler owners would approach the company that originally designed the boiler or burner system to design a burner system to reduce emissions. It was commonly believed that the boiler manufacturer had the greatest expertise in the area of NO{sub x} reduction. Current experience demonstrates that boiler owners are accepting new approaches to reducing NO{sub x} from non-OEM designers and suppliers.more » This paper outlines new approaches being applied by boiler operators to reduce NO{sub x} emissions. Several steps are imperative for a successful NO{sub x} reduction program and each step of this process will be described with examples presented. Concepts that will be examined are: (1) Practical designing concerns of theoretical Low NO{sub x} combustion, (2) Reviewing scope requirements required to reduce emissions, and (3) Teaming with the Customer to facilitate retrofit design and installation. The emphasis of this paper is not directed at the theory of how the components reduce NO{sub x}, but how to effectively apply proven technology that reduced NO{sub x} emissions.« less

  19. Curbing Air Pollution and Greenhouse Gas Emissions from Industrial Boilers in China

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shen, Bo; Price, Lynn K; Lu, Hongyou

    China’s industrial boiler systems consume 700 million tons of coal annually, accounting for 18% of the nation’s total coal consumption. Together these boiler systems are one of the major sources of China’s greenhouse gas (GHG) emissions, producing approximately 1.3 gigatons (Gt) of carbon dioxide (CO 2) annually. These boiler systems are also responsible for 33% and 27% of total soot and sulfur dioxide (SO2) emissions in China, respectively, making a substantial contribution to China’s local environmental degradation. The Chinese government - at both the national and local level - is taking actions to mitigate the significant greenhouse gas (GHG) emissionsmore » and air pollution related to the country’s extensive use of coal-fired industrial boilers. The United States and China are pursuing a collaborative effort under the U.S.-China Climate Change Working Group to conduct a comprehensive assessment of China’s coal-fired industrial boilers and to develop an implementation roadmap that will improve industrial boiler efficiency and maximize fuel-switching opportunities. Two Chinese cities – Ningbo and Xi’an – have been selected for the assessment. These cities represent coastal areas with access to liquefied natural gas (LNG) imports and inland regions with access to interprovincial natural gas pipelines, respectively.« less

  20. Experimental investigation of domestic micro-CHP based on the gas boiler fitted with ORC module

    NASA Astrophysics Data System (ADS)

    Wajs, Jan; Mikielewicz, Dariusz; Bajor, Michał; Kneba, Zbigniew

    2016-09-01

    The results of investigations conducted on the prototype of vapour driven micro-CHP unit integrated with a gas boiler are presented. The system enables cogeneration of heat and electric energy to cover the energy demand of a household. The idea of such system is to produce electricity for own demand or for selling it to the electric grid - in such situation the system user will became the prosumer. A typical commercial gas boiler, additionally equipped with an organic Rankine cycle (ORC) module based on environmentally acceptable working fluid can be regarded as future generation unit. In the paper the prototype of innovative domestic cogenerative ORC system, consisting of a conventional gas boiler and a small size axial vapour microturbines (in-house designed for ORC and the commercially available for Rankine cycle (RC)), evaporator and condenser were scrutinised. In the course of study the fluid working temperatures, rates of heat, electricity generation and efficiency of the whole system were obtained. The tested system could produce electricity in the amount of 1 kWe. Some preliminary tests were started with water as working fluid and the results for that case are also presented. The investigations showed that domestic gas boiler was able to provide the saturated/superheated ethanol vapour (in the ORC system) and steam (in the RC system) as working fluids.

  1. Energy storage as heat-of-fusion in containerized salts. Report on energy storage boiler tank

    NASA Astrophysics Data System (ADS)

    Chubb, T. A.; Nemecek, J. J.; Simmons, D. E.

    1980-06-01

    This report is concerned with energy storage based on heat-of-fusion in containerized salt. The 'energy storage boiler tank' uses evaporation and condensation of a heat transfer fluid to provide heat transfer into and out of stacked cans of salt. The 'energy storage superheater tank' uses a network of alkali metal heat pipes to distribute heat throughout a building filled with salt cans. It uses a radiation to transfer energy to and from stacked cans of salt. The paper summarizes the rationale for energy storage in containerized salt, it discusses salt availability, salt processing, container requirements, can technology and heat transfer fluid degradation problems. These discussions lead to estimates of energy storage system costs. The Naval Research Laboratory is building a 2 MWht proof-of-concept energy storage boiler tank. Laboratory investigations studying the compatibility of the heat transfer fluid with the molten storage salt are described, along with measurements of temperature drops associated with the energy input process. An assessment of the current status of the energy storage boiler tank is presented.

  2. Automating data analysis during the inspection of boiler tubes using line scanning thermography

    NASA Astrophysics Data System (ADS)

    Ley, Obdulia; Momeni, Sepand; Ostroff, Jason; Godinez, Valery

    2012-05-01

    Failures in boiler waterwalls can occur when a relatively small amount of corrosion and loss of metal have been experienced. This study presents our efforts towards the application of Line Scanning Thermography (LST) for the analysis of thinning in boiler waterwall tubing. LST utilizes a line heat source to thermally excite the surface to be inspected and an infrared detector to record the transient surface temperature increase observed due to the presence of voids, thinning or other defects. In waterwall boiler tubes the defects that can be detected using LST correspond to corrosion pitting, hydrogen damage and wall thinning produced by inadequate burner heating or problems with the water chemistry. In this paper we discuss how the LST technique is implemented to determine thickness from the surface temperature data, and we describe our efforts towards developing a semiautomatic analysis tool to speed up the time between scanning, reporting and implementing repairs. We compare the density of data produced by the common techniques used to assess wall thickness and the data produced by LST.

  3. Feasibility of a medium-size central cogenerated energy facility, energy management memorandum

    NASA Astrophysics Data System (ADS)

    Porter, R. W.

    1982-09-01

    The thermal-economic feasibility was studied of a medium-size central cogenerated energy facility designed to serve five varied industries. Generation options included one dual-fuel diesel and one gas turbine, both with waste heat boilers, and five fired boilers. Fuels included natural gas, and for the fired-boiler cases, also low-sulphur coal and municipal refuse. The fired-boiler cogeneration systems employed back-pressure steam turbines. For coal and refuse, the option of steam only without cogeneration was also assessed. The refuse-fired cases utilized modular incinerators. The options provided for a wide range of steam and electrical capacities. Deficient steam was assumed generated independently in existing equipment. Excess electrical power over that which could be displaced was assumed sold to Commonwealth Edison Company under PURPA (Public Utility Regulator Policies Act). The facility was assumed operated by a mutually owned corporation formed by the cogenerated power users. The economic analysis was predicted on currently applicable energy-investment tax credits and accelerated depreciation for a January 1985 startup date. Based on 100% equity financing, the results indicated that the best alternative was the modular-incinerator cogeneration system.

  4. Sensing system for detection and control of deposition on pendant tubes in recovery and power boilers

    DOEpatents

    Kychakoff, George [Maple Valley, WA; Afromowitz, Martin A [Mercer Island, WA; Hogle, Richard E [Olympia, WA

    2008-10-14

    A system for detection and control of deposition on pendant tubes in recovery and power boilers includes one or more deposit monitoring sensors operating in infrared regions of about 4 or 8.7 microns and directly producing images of the interior of the boiler, or producing feeding signals to a data processing system for information to enable a distributed control system by which the boilers are operated to operate said boilers more efficiently. The data processing system includes an image pre-processing circuit in which a 2-D image formed by the video data input is captured, and includes a low pass filter for performing noise filtering of said video input. It also includes an image compensation system for array compensation to correct for pixel variation and dead cells, etc., and for correcting geometric distortion. An image segmentation module receives a cleaned image from the image pre-processing circuit for separating the image of the recovery boiler interior into background, pendant tubes, and deposition. It also accomplishes thresholding/clustering on gray scale/texture and makes morphological transforms to smooth regions, and identifies regions by connected components. An image-understanding unit receives a segmented image sent from the image segmentation module and matches derived regions to a 3-D model of said boiler. It derives a 3-D structure the deposition on pendant tubes in the boiler and provides the information about deposits to the plant distributed control system for more efficient operation of the plant pendant tube cleaning and operating systems.

  5. EVALUATION OF UTILITY BOILER RADIANT FURNACE RESIDENCE TIME/TEMPERATURE CHARACTERISTICS: FIELD TESTS AND HEAT TRANSFER MODELING

    EPA Science Inventory

    The report describes an investigation of the adequacy of a modeling approach in predicting the thermal environment and flow field of pulverized-coal-fired utility boilers. Two 420 MWe coal-fired boilers were evaluated: a single-wall-fired unit and a tangentially fired unit, repre...

  6. 46 CFR 56.50-30 - Boiler feed piping.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... least two separate means of supplying feed water for the boilers. All feed pumps shall be fitted with... allowable stress for design purposes shall be selected as described in § 56.07-10(e) at a temperature not... for water tube boilers shall have fresh water connections only. Care shall be taken to prevent the...

  7. 46 CFR 56.50-30 - Boiler feed piping.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... least two separate means of supplying feed water for the boilers. All feed pumps shall be fitted with... allowable stress for design purposes shall be selected as described in § 56.07-10(e) at a temperature not... for water tube boilers shall have fresh water connections only. Care shall be taken to prevent the...

  8. 40 CFR 63.7541 - How do I demonstrate continuous compliance under the emission averaging provision?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... solid fuel boilers participating in the emissions averaging option as determined in § 63.7522(f) and (g... this section. (i) For each existing solid fuel boiler participating in the emissions averaging option... below the applicable limit. (ii) For each group of boilers participating in the emissions averaging...

  9. 76 FR 1192 - Notice of Lodging of Consent Decree Under the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-07

    ..., the Commonwealth will control particulate matter emissions at the facilities by either shutting down coal-fired boilers, installing air emission controls, or converting the coal-fired boilers to natural gas-fired boilers. The Commonwealth will pay a civil penalty of $300,000 for past violations. The...

  10. 46 CFR 61.05-20 - Boiler safety valves.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 2 2013-10-01 2013-10-01 false Boiler safety valves. 61.05-20 Section 61.05-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PERIODIC TESTS AND..., superheater, or reheater of a boiler shall be tested at the interval specified by table 61.05-10. [CGD 95-028...

  11. 46 CFR 61.05-20 - Boiler safety valves.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false Boiler safety valves. 61.05-20 Section 61.05-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PERIODIC TESTS AND..., superheater, or reheater of a boiler shall be tested at the interval specified by table 61.05-10. [CGD 95-028...

  12. 46 CFR 61.05-20 - Boiler safety valves.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Boiler safety valves. 61.05-20 Section 61.05-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PERIODIC TESTS AND..., superheater, or reheater of a boiler shall be tested at the interval specified by table 61.05-10. [CGD 95-028...

  13. 46 CFR 61.05-20 - Boiler safety valves.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Boiler safety valves. 61.05-20 Section 61.05-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PERIODIC TESTS AND..., superheater, or reheater of a boiler shall be tested at the interval specified by table 61.05-10. [CGD 95-028...

  14. 46 CFR 61.05-20 - Boiler safety valves.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Boiler safety valves. 61.05-20 Section 61.05-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PERIODIC TESTS AND..., superheater, or reheater of a boiler shall be tested at the interval specified by table 61.05-10. [CGD 95-028...

  15. 46 CFR 52.25-1 - General.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false General. 52.25-1 Section 52.25-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Other Boiler Types § 52.25-1 General. Requirements for fired boilers of various sizes and uses are referenced in Table 54.01-5(a) of...

  16. 46 CFR 52.01-35 - Auxiliary, donkey, fired thermal fluid heater, and heating boilers.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Auxiliary, donkey, fired thermal fluid heater, and heating boilers. 52.01-35 Section 52.01-35 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS General Requirements § 52.01-35 Auxiliary, donkey, fired thermal...

  17. 46 CFR 52.01-35 - Auxiliary, donkey, fired thermal fluid heater, and heating boilers.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false Auxiliary, donkey, fired thermal fluid heater, and heating boilers. 52.01-35 Section 52.01-35 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS General Requirements § 52.01-35 Auxiliary, donkey, fired thermal...

  18. 46 CFR 52.25-1 - General.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false General. 52.25-1 Section 52.25-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Other Boiler Types § 52.25-1 General. Requirements for fired boilers of various sizes and uses are referenced in table 54.01-5(a) of...

  19. 46 CFR 52.01-35 - Auxiliary, donkey, fired thermal fluid heater, and heating boilers.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Auxiliary, donkey, fired thermal fluid heater, and heating boilers. 52.01-35 Section 52.01-35 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS General Requirements § 52.01-35 Auxiliary, donkey, fired thermal...

  20. 46 CFR 52.01-35 - Auxiliary, donkey, fired thermal fluid heater, and heating boilers.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 2 2013-10-01 2013-10-01 false Auxiliary, donkey, fired thermal fluid heater, and heating boilers. 52.01-35 Section 52.01-35 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS General Requirements § 52.01-35 Auxiliary, donkey, fired thermal...

  1. 46 CFR 52.25-1 - General.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false General. 52.25-1 Section 52.25-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Other Boiler Types § 52.25-1 General. Requirements for fired boilers of various sizes and uses are referenced in Table 54.01-5(a) of...

  2. 46 CFR 52.25-1 - General.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 2 2013-10-01 2013-10-01 false General. 52.25-1 Section 52.25-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Other Boiler Types § 52.25-1 General. Requirements for fired boilers of various sizes and uses are referenced in table 54.01-5(a) of...

  3. 78 FR 63181 - Information Collection Request Submitted to OMB for Review and Approval; Comment Request...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-23

    ... Request Submitted to OMB for Review and Approval; Comment Request; Information Requirements for Boilers...), ``Information Requirements for Boilers and Industrial Furnaces (Renewal)'' (EPA ICR No. ICR No. 1361.16, OMB... http://www.epa.gov/dockets . Abstract: EPA regulates the burning of hazardous waste in boilers...

  4. FORMATION OF CHLORINATED DIOXINS AND FURANS IN A HAZARDOUS-WASTE-FIRING INDUSTRIAL BOILER

    EPA Science Inventory

    This research examined the potential for emissions of polychlorinated diebnzodioxin and dibenzofuran (PCDD/F) from industrial boilers that cofire hazardous waste. PCDD/F emissions were sampled from a 732 kW (2.5 x 106 Btu/h), 3-pass, firetube boiler using #2 fuel oil cofired wit...

  5. 46 CFR 52.25-1 - General.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false General. 52.25-1 Section 52.25-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Other Boiler Types § 52.25-1 General. Requirements for fired boilers of various sizes and uses are referenced in Table 54.01-5(a) of...

  6. 76 FR 61999 - Energy Conservation Program for Consumer Products: Test Procedures for Residential Furnaces and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-06

    ... for Residential Furnaces and Boilers (Standby Mode and Off Mode); Correction AGENCY: Office of Energy... Consumer Products: Test Procedures for Residential Furnaces and Boilers. This correction provides the... page 56339, in the third column after ``2. E- mail:'' the e-mail address should read `` FurnaceBoiler...

  7. 78 FR 53625 - Energy Conservation Program for Consumer Products: Test Procedures for Residential Furnaces and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-30

    ... Program for Consumer Products: Test Procedures for Residential Furnaces and Boilers; Correction AGENCY... Federal Register that amended the test procedure for residential furnaces and boilers (78 FR 41265). Due...., Washington, DC 20585-0121. Telephone: (202) 586-6590. Email: residential_furnaces_and_boilers@ee.doe.gov . Mr...

  8. 10 CFR 431.82 - Definitions concerning commercial packaged boilers.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...) For service water heating in buildings but does not meet the definition of “hot water supply boiler” in this part. Condensing boiler means a commercial packaged boiler that condenses part of the water vapor in the flue gases, and that includes a means of collecting and draining this condensate from its...

  9. 46 CFR 56.50-30 - Boiler feed piping.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... APPURTENANCES Design Requirements Pertaining to Specific Systems § 56.50-30 Boiler feed piping. (a) General... paragraph (d) or (e) of this section. (2) Feed pump supply to power boilers may utilize the group feed... required stop and stop-check valves, shall be designed for either the feed pump relief valve setting or the...

  10. 46 CFR 56.50-30 - Boiler feed piping.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... APPURTENANCES Design Requirements Pertaining to Specific Systems § 56.50-30 Boiler feed piping. (a) General... paragraph (d) or (e) of this section. (2) Feed pump supply to power boilers may utilize the group feed... required stop and stop-check valves, shall be designed for either the feed pump relief valve setting or the...

  11. 76 FR 41742 - Approval and Promulgation of Air Quality Implementation Plans; Pennsylvania; Control of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-15

    ... the Operation of Outdoor Wood-Fired Boilers AGENCY: Environmental Protection Agency (EPA). ACTION... from the operation of outdoor wood-fired boilers. This action is being taken under the Clean Air Act... the operation of outdoor wood-fired boilers (OWBs). I. Background On July 18, 1997 (62 FR 38652), EPA...

  12. Energy storage-boiler tank

    NASA Astrophysics Data System (ADS)

    Chubb, T. A.; Nemecek, J. J.; Simmons, D. E.

    1980-03-01

    Activities performed in an effort to demonstrate heat of fusion energy storage in containerized salts are reported. The properties and cycle life characteristics of a eutectic salt having a boiling point of about 385 C (NaCl, KCl, Mg Cl2) were determined. M-terphenyl was chosen as the heat transfer fluid. Compatibility studies were conducted and mild steel containers were selected. The design and fabrication of a 2MWh storage boiler tank are discussed.

  13. Making the Connection: Beneficial Collaboration Between Army Installations and Energy Utility Companies

    DTIC Science & Technology

    2011-01-01

    natural gas vehicle-fueling station, improving the efficiency of boilers, installing a generating system to supplement the electricity purchased during...voltage regulation of transformers in its substations to improve energy efficiency and a small study on customer assistance, both at BPA’s own expense...Fort Campbell has installed more energy efficient boilers, HVAC systems , hot water heaters, lighting, 10 A ground source heat pump (GSHP), also

  14. Conversion of Army Heating Plants to Coal: Three Case Studies

    DTIC Science & Technology

    1982-03-01

    compared to the 50% wet sludge flue gas desulfurized product. All fly ash produced is collected without further processing. The product can be used to...Existing Turbine Generators 26 11 Picatinny Arsenal -- Summary of Capital Costs for Stoker Boilers, Flue Gas Desulfurization . New Turbine Generators...27 12 Picatinny Arsenal -- Summary of Operating Costs for Stoker Boilers, Flue Gas Desulfurization . New Turbine Generators 28 13 Picatinny Arsenal

  15. Energy storage-boiler tank

    NASA Technical Reports Server (NTRS)

    Chubb, T. A.; Nemecek, J. J.; Simmons, D. E.

    1980-01-01

    Activities performed in an effort to demonstrate heat of fusion energy storage in containerized salts are reported. The properties and cycle life characteristics of a eutectic salt having a boiling point of about 385 C (NaCl, KCl, Mg Cl2) were determined. M-terphenyl was chosen as the heat transfer fluid. Compatibility studies were conducted and mild steel containers were selected. The design and fabrication of a 2MWh storage boiler tank are discussed.

  16. System and method for coproduction of activated carbon and steam/electricity

    DOEpatents

    Srinivasachar, Srivats [Sturbridge, MA; Benson, Steven [Grand Forks, ND; Crocker, Charlene [Newfolden, MN; Mackenzie, Jill [Carmel, IN

    2011-07-19

    A system and method for producing activated carbon comprising carbonizing a solid carbonaceous material in a carbonization zone of an activated carbon production apparatus (ACPA) to yield a carbonized product and carbonization product gases, the carbonization zone comprising carbonaceous material inlet, char outlet and carbonization gas outlet; activating the carbonized product via activation with steam in an activation zone of the ACPA to yield activated carbon and activation product gases, the activation zone comprising activated carbon outlet, activation gas outlet, and activation steam inlet; and utilizing process gas comprising at least a portion of the carbonization product gases or a combustion product thereof; at least a portion of the activation product gases or a combustion product thereof; or a combination thereof in a solid fuel boiler system that burns a solid fuel boiler feed with air to produce boiler-produced steam and flue gas, the boiler upstream of an air heater within a steam/electricity generation plant, said boiler comprising a combustion zone, a boiler-produced steam outlet and at least one flue gas outlet.

  17. Analysis of thermal radiation in coal-fired furnaces

    NASA Astrophysics Data System (ADS)

    Miles, Jonathan J.; Hammaker, Robert G.; Madding, Robert P.; Sunderland, J. E.

    1997-04-01

    Many utilities throughout the United States have added infrared scanning to their arsenal of techniques for inspection and predictive maintenance programs. Commercial infrared scanners are not designed, however, to withstand the searing interiors of boilers, which can exceed 2500 degrees Fahrenheit. Two high-temperature lenses designed to withstand the hostile environment inside a boiler for extended periods of time were developed by the EPRI M&D Center, thus permitting real-time measurement of steam tube temperatures and subsequent analysis of tube condition, inspection of burners, and identification of hot spots. A study was conducted by Sunderland Engineering, Inc. and EPRI M&D in order to characterize the radiative interactions that affect infrared measurements made inside a commercial, coal- fired, water-tube boiler. A comprehensive literature search exploring the existing record of results pertaining to analytical and experimental determination of radiative properties of coal-combustion byproducts was performed. An experimental component intended to provide data for characterization of the optical properties of hot combustion byproducts inside a coal-fired furnace was carried out. The results of the study indicate that hot gases, carbon particles, and fly ash, which together compose the medium inside a boiler, affect to varying degrees the transport of infrared radiation across a furnace. Techniques for improved infrared measurement across a coal-fired furnace are under development.

  18. 11. RW Meyer Sugar Mill: 18761889. Locomotive=type, firetube, portable boiler, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. RW Meyer Sugar Mill: 1876-1889. Locomotive=type, fire-tube, portable boiler, model No. 1, Manufactured by Ames Iron Works, Oswego, New York, 1879. 120 lbs./sq. in. working pressure, 66 sq. ft. heating surface in tubes. View: the boiler provided steam for steam engine which in turn powered the centrifugals. View shows front fire box, end of boiler. Below fire-box,used for removing ashes, is a door. Circular openings at the rear of the fire-box are where fire-tubes connected with furnace. Column to right of fire-box carried pressure and water level gauges. Fluted chimney-type structure is steam-port, safety valve, and whistle. Weights originally sat on the arm extending from the top of the port and controlled the boiler pressure. - R. W. Meyer Sugar Mill, State Route 47, Kualapuu, Maui County, HI

  19. A SURVEY OF CONVENTIONAL STEAM BOILER EXPERIENCE APPLICABLE TO THE HTGR STEAM GENERATORS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paget, J.A.

    1959-10-01

    BS>The steam generator of a high temperature gas-cooled reactor consists of tubular heating surface inside a shell which forms part of the primary He circuit of the reactor. When a tube fails in such a steam generator, moisture in the form of steam is released into the He steam and is carried through the reactor where it will cause corrosion and mass transfer of C in the core. A paramount consideration in the design of a steam generator for a high temperature gas-cooled reactor is the prevention of tube failures. Preference, therefore, should be given to a forced circulation design.more » The Loeffler Boiler would be the best from this standpoint alone since only steam enters the tubes, and its circulation rate can be maintained at an adequate value to insure cool tubes regardless of load fluctuations. The next type in the order of preference would be the forced recirculation boiler, since at least the boiier tubes always have an adequate cooling flow regardless of output. The third type in order of preference would be a Sulzer Type boiler since it has a separator to remove dissolved material from the water which is comparible in efficiency to a standard boiler drum and although the flow through evaporator and superheater fluctuates with load, the Sulzer Boiler can be operated as a forced recirculation boiler at low loads. The least desirable type would be a Benson or supercritical boiler which is completely dependent on input water purity for its survival. It is not claimed that Benson or supercritical boilers should not or will not be used in the future for gas-cooled reactors, but only that their use would be the least conservative choice from a tube failure standpoint at the present time. (auth)« less

  20. Fireside corrosion in kraft recovery boilers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tran, H.N.; Barham, D.; Hupa, M.

    1988-01-01

    Causes and corrective measures are reviewed for several common types of fireside corrosion in kraft recovery boilers. Corrosion differs significantly with location in the boiler due tio the great differences in metal surface temperature and deposit and flue gas chemistry. Sulphidation corrosion associated with sulphur-bearing gases under reducing conditions is dominant in the lower furnace, while sulphidation/oxidation resulting from gas-deposit-metal reactions is important in the upper boiler. In many cases, although corrosion has been controlled by ensuring the absence of a molten phase at the metal surface, the corrosion mechanism is not fully understood.

  1. Numerical Simulation in a Supercirtical CFB Boiler

    NASA Astrophysics Data System (ADS)

    Zhang, Yanjun; Gaol, Xiang; Luo, Zhongyang; Jiang, Xiaoguo

    The dimension of the hot circulation loop of the supercritical CFB boiler is large, and there are many unknowns and challenges that should be identified and resolved during the development. In order to realize a reasonable and reliable design of the hot circulation loop, numerical simulation of gas-solid flow in a supercritical CFB boiler was conducted by using FLUENT software. The working condition of hot circulation loop flow field, gas-solid flow affected by three unsymmetrical cyclones, air distribution and pressure drop in furnace were analyzed. The simulation results showed that the general arrangement of the 600MWe supercritical CFB boiler is reasonable.

  2. Naftokrak-Naftdbudowa & MPEC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Szewczyk, T.; Mazur, J.

    1995-12-31

    Polish graded coal is being burned on existing stoker boilers at MPEC`s Balicka plant, using Control Techtronics microprocess-based system. Pictures were shown of the equipment controlling three hot water WR-10 boilers, and (two) steam 22.5 boilers. The results of this installation include; 85% reduction in stack particulate emission, 25% increase in boiler energy efficiency, 65% reduction in fan electrical energy, achieving {open_quotes}ultra low fire{close_quotes} which provides 3 or 4 to 1 turndown, versus 2 to 1, for substantially reduced fuel use at low heating requirements, and 2 to 3 years payback on invested capital.

  3. Model-free adaptive control of advanced power plants

    DOEpatents

    Cheng, George Shu-Xing; Mulkey, Steven L.; Wang, Qiang

    2015-08-18

    A novel 3-Input-3-Output (3.times.3) Model-Free Adaptive (MFA) controller with a set of artificial neural networks as part of the controller is introduced. A 3.times.3 MFA control system using the inventive 3.times.3 MFA controller is described to control key process variables including Power, Steam Throttle Pressure, and Steam Temperature of boiler-turbine-generator (BTG) units in conventional and advanced power plants. Those advanced power plants may comprise Once-Through Supercritical (OTSC) Boilers, Circulating Fluidized-Bed (CFB) Boilers, and Once-Through Supercritical Circulating Fluidized-Bed (OTSC CFB) Boilers.

  4. Survey of flue gas desulfurization systems: Hawthorn Station, Kansas City Power and Light Co. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Isaacs, G.A.; Zada, F.K.

    1975-09-01

    Results are given of a survey of the flue gas desulfurization (FGD) systems at Kansas City Power and Light Co.'s Hawthorn Power Station. The FGD systems on Hawthorn boilers 3 and 4 were designed to operate by injection of dry limestone in the boiler's furnace, followed by tail gas scrubbing. Because of tube plugging in boiler 4 the mode of operation of the FGD system on that boiler was modified: ground limestone is now introduced into the flue gas near the gas inlet to the scrubber tower. (GRA)

  5. 1300°F 800 MWe USC CFB Boiler Design Study

    NASA Astrophysics Data System (ADS)

    Robertson, Archie; Goidich, Steve; Fan, Zhen

    Concern about air emissions and the effect on global warming is one of the key factors for developing and implementing new advanced energy production solutions today. One state-of-the-art solution is circulating fluidized bed (CFB) combustion technology combined with a high efficiency once-through steam cycle. Due to this extremely high efficiency, the proven CFB technology offers a good solution for CO2 reduction. Its excellent fuel flexibility further reduces CO2 emissions by co-firing coal with biomass. Development work is under way to offer CFB technology up to 800MWe capacities with ultra-supercritical (USC) steam parameters. In 2009 a 460MWe once-through supercritical (OTSC) CFB boiler designed and constructed by Foster Wheeler will start up. However, scaling up the technology further to 600-800MWe with net efficiency of 45-50% is needed to meet the future requirements of utility operators. To support the move to these larger sizes, an 800MWe CFB boiler conceptual design study was conducted and is reported on herein. The use of USC conditions (˜11 00°F steam) was studied and then the changes, that would enable the unit to generate 1300°F steam, were identified. The study has shown that by using INTREX™ heat exchangers in a unique internal-external solids circulation arrangement, Foster Wheeler's CFB boiler configuration can easily accommodate 1300°F steam and will not require a major increase in heat transfer surface areas.

  6. Online Monitoring System of Air Distribution in Pulverized Coal-Fired Boiler Based on Numerical Modeling

    NASA Astrophysics Data System (ADS)

    Żymełka, Piotr; Nabagło, Daniel; Janda, Tomasz; Madejski, Paweł

    2017-12-01

    Balanced distribution of air in coal-fired boiler is one of the most important factors in the combustion process and is strongly connected to the overall system efficiency. Reliable and continuous information about combustion airflow and fuel rate is essential for achieving optimal stoichiometric ratio as well as efficient and safe operation of a boiler. Imbalances in air distribution result in reduced boiler efficiency, increased gas pollutant emission and operating problems, such as corrosion, slagging or fouling. Monitoring of air flow trends in boiler is an effective method for further analysis and can help to appoint important dependences and start optimization actions. Accurate real-time monitoring of the air distribution in boiler can bring economical, environmental and operational benefits. The paper presents a novel concept for online monitoring system of air distribution in coal-fired boiler based on real-time numerical calculations. The proposed mathematical model allows for identification of mass flow rates of secondary air to individual burners and to overfire air (OFA) nozzles. Numerical models of air and flue gas system were developed using software for power plant simulation. The correctness of the developed model was verified and validated with the reference measurement values. The presented numerical model for real-time monitoring of air distribution is capable of giving continuous determination of the complete air flows based on available digital communication system (DCS) data.

  7. High-Temperature Graphitization Failure of Primary Superheater Tube

    NASA Astrophysics Data System (ADS)

    Ghosh, D.; Ray, S.; Roy, H.; Mandal, N.; Shukla, A. K.

    2015-12-01

    Failure of boiler tubes is the main cause of unit outages of the plant, which further affects the reliability, availability and safety of the unit. So failure analysis of boiler tubes is absolutely essential to predict the root cause of the failure and the steps are taken for future remedial action to prevent the failure in near future. This paper investigates the probable cause/causes of failure of the primary superheater tube in a thermal power plant boiler. Visual inspection, dimensional measurement, chemical analysis, metallographic examination and hardness measurement are conducted as the part of the investigative studies. Apart from these tests, mechanical testing and fractographic analysis are also conducted as supplements. Finally, it is concluded that the superheater tube is failed due to graphitization for prolonged exposure of the tube at higher temperature.

  8. Efficiency of using direct-flow burners and nozzles in implementation of dry-bottom ash removal at the TPP-210A boiler furnace

    NASA Astrophysics Data System (ADS)

    Arkhipov, A. M.; Kanunnikov, A. A.; Kirichkov, V. S.; Prokhorov, V. B.; Fomenko, M. V.; Chernov, S. L.

    2017-02-01

    In reconstruction of operating pulverized coal-fired boilers, one of the main factors is the choice of a method for slag removal: dry bottom ash removal (DBAR) or slag-tap removal (STR). In this case, ecological and economic aspects should be taken into account, and also the early ignition of pulverized coal fuel, the reliability of operation of the furnace walls in the mode without slagging, and the stability of slag removal should be provided. In this work, issues of changeover of the pulverized coal-fired boilers of the TPP-210A type from the STR mode to the DBAR mode are considered. As of today, the main problems during the operation of these boilers are the high emissions of nitrogen oxides together with flue gases into the atmosphere and the appropriated payoffs, a small range of loads available, the necessity of stabilization of the pulverizedcoal flame sustainability by using the highly reactive fuel, large mechanical fuel underburning, etc. Results of studying aerodynamics of a furnace with DBAR obtained in the process of physical simulation are given; technical solutions and preliminary design (configuration of burners and nozzles in the boiler furnace, conceptual design of the pulverized coal burner, configuration of TPP-210A boiler with the low heat liberation of furnace cross-section and volumetric heat release) are set forth, which are associated with the optimization of aerodynamics of furnace volume, when the direct-flow burners and nozzles are used, and with organization of the efficient staged combustion of solid fuel. Two versions of possible modernization of a boiler unit are considered. Under conditions of the planned increase in the steam production capacity, the most promising measures are as follows: the DBAR implementation with reducing heat releases of the cross-section and volume of the furnace approximately by half, the installation of the direct-flow burners and nozzles with injection of recirculation gases into the active combustion zone by bleeding them from the turning chamber.

  9. 9 CFR 91.22 - Protection from heat of boilers and engines.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 1 2011-01-01 2011-01-01 false Protection from heat of boilers and engines. 91.22 Section 91.22 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE... Protection from heat of boilers and engines. No animals shall be stowed along the alleyways leading to the...

  10. 9 CFR 91.22 - Protection from heat of boilers and engines.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Protection from heat of boilers and engines. 91.22 Section 91.22 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE... Protection from heat of boilers and engines. No animals shall be stowed along the alleyways leading to the...

  11. 10 CFR 431.106 - Uniform test method for the measurement of energy efficiency of commercial water heaters and hot...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... efficiency of commercial water heaters and hot water supply boilers (other than commercial heat pump water... PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Commercial Water Heaters, Hot Water Supply Boilers... of energy efficiency of commercial water heaters and hot water supply boilers (other than commercial...

  12. 77 FR 49830 - Notice of Lodging of Proposed Amendment to the Consent Decree Under the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-17

    ... control particulate matter emissions at its Huntingdon, Pennsylvania facility (``the Huntingdon facility'') by either shutting down coal-fired boilers, installing air emission controls on the existing unit, or converting the coal-fired boilers to natural gas-fired boilers by June 30, 2012. The Commonwealth did not...

  13. 9 CFR 91.22 - Protection from heat of boilers and engines.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 9 Animals and Animal Products 1 2012-01-01 2012-01-01 false Protection from heat of boilers and engines. 91.22 Section 91.22 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE... Protection from heat of boilers and engines. No animals shall be stowed along the alleyways leading to the...

  14. 9 CFR 91.22 - Protection from heat of boilers and engines.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 9 Animals and Animal Products 1 2014-01-01 2014-01-01 false Protection from heat of boilers and engines. 91.22 Section 91.22 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE... Protection from heat of boilers and engines. No animals shall be stowed along the alleyways leading to the...

  15. 9 CFR 91.22 - Protection from heat of boilers and engines.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 9 Animals and Animal Products 1 2013-01-01 2013-01-01 false Protection from heat of boilers and engines. 91.22 Section 91.22 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE... Protection from heat of boilers and engines. No animals shall be stowed along the alleyways leading to the...

  16. 30 CFR 57.13001 - General requirements for boilers and pressure vessels.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false General requirements for boilers and pressure vessels. 57.13001 Section 57.13001 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Compressed Air and Boilers §...

  17. 30 CFR 56.13001 - General requirements for boilers and pressure vessels.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false General requirements for boilers and pressure vessels. 56.13001 Section 56.13001 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Compressed Air and Boilers §...

  18. Central Heat Plant Modernization: FY98 Update and Recommendations.

    DTIC Science & Technology

    1999-12-01

    Boiler and Pressure Vessel Code suggests an inspection frequency of 12 months for...28 April 1997). ASME International, Boiler and Pressure Vessel Code (ASME International, New York, NY, 1995). Bloomquist, R.G., J.D. Nimmons, and K...Services (HQDA, 28 April 1997). ASME International, Boiler and Pressure Vessel Code (ASME International, New York, NY, 1995). Bloomquist, R.G.,

  19. Ultrasonic Inspection and Fatigue Evaluation of Critical Pore Size in Welds.

    DTIC Science & Technology

    1981-09-01

    Boiler and Pressure Vessel Code ) 20...Five porosity levels were produced that parallelled ASME boiler and pressure vessel code specification (Section VIII). Appendix IV of the pressure...Figure 2 shows porosity charts (ASME Boiler and Pressure Vessel Code ) which classify and designate the number and size of pores in any six inch length

  20. Status of Metric Conversion A Survey of U.S. Standards Writing Organizations.

    DTIC Science & Technology

    1982-05-01

    Boiler and Pressure Vessel Code . 7...to and consistent with metrication of the ASME Boiler and Pressure Vessel Code . The Electrical Apparatus Service Association is a trade asso- ciation...metrication of TEMA Standards will be compatible to and consistent with metrication of the ASME Boiler and Pressure Vessel Code . TEMA’s metrication

  1. 30 CFR 57.13001 - General requirements for boilers and pressure vessels.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false General requirements for boilers and pressure vessels. 57.13001 Section 57.13001 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Compressed Air and Boilers §...

  2. 30 CFR 57.13001 - General requirements for boilers and pressure vessels.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false General requirements for boilers and pressure vessels. 57.13001 Section 57.13001 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Compressed Air and Boilers §...

  3. Supercritical and Transcritical Shear Flows in Microgravity: Experiments and Direct Numerical Simulations

    DTIC Science & Technology

    2006-08-01

    Boiler and Pressure Vessel Code were con...GRC, and to specifically state a general operating requirement. 1.1. The entire apparatus will be designed to ASME Boiler and Pressure Vessel Code , whenever...calculations, including a finite element analysis (FEA) will be inspected to verify the ASME Boiler and Pressure Vessel Code has been me, whenever

  4. 30 CFR 56.13001 - General requirements for boilers and pressure vessels.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false General requirements for boilers and pressure vessels. 56.13001 Section 56.13001 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Compressed Air and Boilers §...

  5. 30 CFR 56.13001 - General requirements for boilers and pressure vessels.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false General requirements for boilers and pressure vessels. 56.13001 Section 56.13001 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Compressed Air and Boilers §...

  6. 30 CFR 57.13001 - General requirements for boilers and pressure vessels.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false General requirements for boilers and pressure vessels. 57.13001 Section 57.13001 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Compressed Air and Boilers §...

  7. 30 CFR 56.13001 - General requirements for boilers and pressure vessels.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false General requirements for boilers and pressure vessels. 56.13001 Section 56.13001 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Compressed Air and Boilers §...

  8. 30 CFR 57.13001 - General requirements for boilers and pressure vessels.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false General requirements for boilers and pressure vessels. 57.13001 Section 57.13001 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Compressed Air and Boilers §...

  9. 30 CFR 56.13001 - General requirements for boilers and pressure vessels.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false General requirements for boilers and pressure vessels. 56.13001 Section 56.13001 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Compressed Air and Boilers §...

  10. 46 CFR 167.65-60 - Examination of boilers and machinery by engineer.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Examination of boilers and machinery by engineer. 167.65-60 Section 167.65-60 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL... machinery by engineer. It shall be the duty of an engineer when he assumes charge of the boilers and...

  11. 46 CFR 167.65-60 - Examination of boilers and machinery by engineer.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Examination of boilers and machinery by engineer. 167.65-60 Section 167.65-60 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL... machinery by engineer. It shall be the duty of an engineer when he assumes charge of the boilers and...

  12. 46 CFR 167.65-60 - Examination of boilers and machinery by engineer.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Examination of boilers and machinery by engineer. 167.65-60 Section 167.65-60 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL... machinery by engineer. It shall be the duty of an engineer when he assumes charge of the boilers and...

  13. 46 CFR 167.65-60 - Examination of boilers and machinery by engineer.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Examination of boilers and machinery by engineer. 167.65-60 Section 167.65-60 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL... machinery by engineer. It shall be the duty of an engineer when he assumes charge of the boilers and...

  14. 40 CFR 63.11211 - How do I demonstrate initial compliance with the emission limits?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Table 4 to this subpart, conducting a fuel analysis for each type of fuel burned in your boiler... single type of fuel, you are exempted from the compliance requirements of conducting a fuel analysis for each type of fuel burned in your boiler. For purposes of this subpart, boilers that use a supplemental...

  15. 40 CFR 63.11211 - How do I demonstrate initial compliance with the emission limits?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Table 4 to this subpart, conducting a fuel analysis for each type of fuel burned in your boiler... single type of fuel, you are exempted from the compliance requirements of conducting a fuel analysis for each type of fuel burned in your boiler. For purposes of this subpart, boilers that use a supplemental...

  16. 76 FR 54993 - Revisions to the California State Implementation Plan, Placer County Air Pollution Control District

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-06

    ... nitrogen (NO X ) emissions from biomass fuel-fired boilers. We are proposing action on a local rule that... Submitted PCAPCD 233 Biomass Boilers......... 12/10/09 05/07/10 On June 8, 2010, the submittal for PCAPCD... from biomass boilers and steam generators. EPA's technical support document (TSD) has more information...

  17. 77 FR 67322 - Revisions to the California State Implementation Plan, Placer County Air Pollution Control District

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-09

    ... Implementation Plan (SIP). These revisions concern oxides of nitrogen (NOx) emissions from biomass boilers. We... PCAPCD 233 Biomass Boilers 06/14/12 09/21/12 On October 11, 2012, EPA determined that the submittal for... that control NO X emissions. Rule 233 limits NO X emissions from biomass boilers. EPA's technical...

  18. 40 CFR 75.53 - Monitoring plan.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Energy and used in the National Allowance Data Base (or equivalent facility ID number assigned by EPA, if...; (C) Type of boiler (or boilers for a group of units using a common stack); (D) Type of fuel(s) fired... more than one fuel, the fuel classification of the boiler; (E) Type(s) of emission controls for SO2...

  19. 40 CFR 75.53 - Monitoring plan.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Energy and used in the National Allowance Data Base (or equivalent facility ID number assigned by EPA, if...; (C) Type of boiler (or boilers for a group of units using a common stack); (D) Type of fuel(s) fired... more than one fuel, the fuel classification of the boiler; (E) Type(s) of emission controls for SO2...

  20. National Emission Standards for Hazardous Air Pollutants (NESHAP) for Major Sources: Industrial, Commercial, and Institutional Boilers - Guidance for Calculating Emission Credits Resulting from Implementation of Energy Conservation Measures

    EPA Pesticide Factsheets

    The purpose of this July 2012 document is to provide guidance for developing a consistent approach to documenting efficiency credits generated from energy conservation measures in the Implementation Plan for boilers covered by the Boiler MACT rule.

  1. 40 CFR 63.7491 - Are any boilers or process heaters not subject to this subpart?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .../infectious waste incinerator covered by 40 CFR part 60, subpart Ce or subpart Ec. (c) An electric utility... furnace stoves as described in the EPA document, entitled “National Emission Standards for Hazardous Air... boilers as defined in this subpart. (o) Blast furnace gas fuel-fired boilers and process heaters as...

  2. 40 CFR 63.1217 - What are the standards for liquid fuel boilers that burn hazardous waste?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... boilers that burn hazardous waste? 63.1217 Section 63.1217 Protection of Environment ENVIRONMENTAL... boilers that burn hazardous waste? (a) Emission limits for existing sources. You must not discharge or... provided for in paragraph (a)(2)(iii) of this section: (i) When you burn hazardous waste with an as-fired...

  3. 40 CFR 63.1217 - What are the standards for liquid fuel boilers that burn hazardous waste?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... boilers that burn hazardous waste? 63.1217 Section 63.1217 Protection of Environment ENVIRONMENTAL... boilers that burn hazardous waste? (a) Emission limits for existing sources. You must not discharge or... provided for in paragraph (a)(2)(iii) of this section: (i) When you burn hazardous waste with an as-fired...

  4. 46 CFR 109.421 - Report of repairs to boilers and pressure vessels.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Report of repairs to boilers and pressure vessels. 109.421 Section 109.421 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS Reports, Notifications, and Records Reports and Notifications § 109.421 Report of repairs to boilers and pressure vessel...

  5. Combustion of Schlamm in ACFB boilers -- The Charbonnages de France Group's experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schroeder, M.; Rollin, J.P.

    Within the context of the rehabilitation of Emile Huchet Power Plant Unit 4 owned by the ``SNET'', a company of the CHARBONNAGES DE FRANCE Group, a new CFB boiler with an electrical capacity of 125 MW has been commissioned in 1990 in replacement for an existing pulverized-coal boiler. This boiler constituted at the time an experimental unit on two accounts. It was an innovation through its size but also its specific design which allows to burn schlamm--a coal washing residue--in the form of pulp. The boiler design answered the CHARBONNAGES DE FRANCE Group's need to eliminate old settling ponds containingmore » schlamm which, from the technical and economic point of view, could not be burnt using conventional combustion techniques owing to its specific characteristics (fine, high-ash product with a very high moisture and clay content). This original method of injection as well as the pulp preparation process suited to this type of injection have been designed and developed by CdF INGENIERIE and the CERCHAR (CdF Group) after many investigations and tests. The experience gained at Emile Huchet Power Plant for more than 7 years confirms that the CFB boiler is a clean combustion technique which is perfectly suited to the combustion of schlamm injected in the form of pulp. The CFB unit burns exclusively schlamm conditioned in the form of pulp with 33% of moisture, and this with a high degree of efficiency, low emission values and a very good availability. This talk include a description of the CFB boiler and the pulp preparation plant as well as a presentation of the boiler performances and of the experience gained by the CHARBONANGES DE FRANCE Group since the new CFB unit has been commissioned.« less

  6. Design and Application of Novel Horizontal Circulating Fluidized Bed Boiler

    NASA Astrophysics Data System (ADS)

    Lit, Q. H.; Zhang, Y. G.; Meng, A. H.

    The vertical circulating fluidized bed (CFB) boiler has been found wide application in power generation and tends to be enlarged in capacity. Because CFB is one of environment friendly and high efficiency combustion technologies, the CFB boiler has also been expected to be used in the industrial area, such as textile mill, region heating, brewery, seed drying and so on. However, the necessary height of furnace is hard to be implemented for CFB with especially small capacity. Thereby, a novel horizontal circulating fluidized bed boiler has been proposed and developed. The horizontal CFB is composed of primary combustion chamber, secondary combustion chamber, burnout chamber, cyclone, loop seal, heat recovery area. The primary combustion chamber is a riser like as that in vertical CFB, and the secondary combustion chamber is a downward passage that is a natural extension of the primary riser, which can reduce the overall height of the boiler. In some extent, the burnout chamber is also the extension of primary riser. The capacity of horizontal CFB is about 4.2-24.5MWth (6-35t/h) steam output or equivalent hot water supply. The hot water boiler of 7MWth and steam boilers of 4.2MWth (6t/h) and 10.5MWth (15t/h) are all designed and working well now. The three units of hot water horizontal CFB boiler were erected in the Neimenggu Autonomous Region, Huhehaote city for region heating. The three units of steam horizontal CFB has been installed in Yunnan, Jiang Xi and Guangdong provinces, respectively. The basic principle for horizontal CFB and experiences for designing and operating are presented in this paper. Some discussions are also given to demonstrate the promising future of horizontal CFB.

  7. Postcombustion and its influences in 135 MWe CFB boilers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shaohua Li; Hairui Yang; Hai Zhang

    2009-09-15

    In the cyclone of a circulating fluidized bed (CFB) boiler, a noticeable increment of flue gas temperature, caused by combustion of combustible gas and unburnt carbon content, is often found. Such phenomenon is defined as post combustion, and it could introduce overheating of reheated and superheated steam and extra heat loss of exhaust flue gas. In this paper, mathematical modeling and field measurements on post combustion in 135MWe commercial CFB boilers were conducted. A novel one-dimensional combustion model taking post combustion into account was developed. With this model, the overall combustion performance, including size distribution of various ashes, temperature profile,more » and carbon content profiles along the furnace height, heat release fraction in the cyclone and furnace were predicted. Field measurements were conducted by sampling gas and solid at different positions in the boiler under different loads. The measured data and corresponding model-calculated results were compared. Both prediction and field measurements showed post combustion introduced a temperature increment of flue gas in the cyclone of the 135MWe CFB boiler in the range of 20-50{sup o}C when a low-volatile bituminous coal was fired. Although it had little influence on ash size distribution, post combustion had a remarkable influence on the carbon content profile and temperature profile in the furnace. Moreover, it introduced about 4-7% heat release in the cyclone over the total heat release in the boiler. This fraction slightly increased with total air flow rate and boiler load. Model calculations were also conducted on other two 135MWe CFB boilers burning lignite and anthracite coal, respectively. The results confirmed that post combustion was sensitive to coal type and became more severe as the volatile content of the coal decreased. 15 refs., 11 figs., 4 tabs.« less

  8. Analysis of Consequences of Using Gas Fuels for Running Auxiliary Ship Boilers in the Light of Contemporary Environmental Protection Requirements

    NASA Astrophysics Data System (ADS)

    Adamkiewicz, Andrzej; Bartoszewski, Marek; Kendra, Martin

    2016-09-01

    The article justifies the application of gas fuels for supplying auxiliary ship boilers. It presents legal regulations on maritime environmental protection areas and their requirements which are in power. It shows the chronology of introduced limitations on sulphur and nitrogen dioxide emissions and thresholds of carbon dioxide emission reduction expressed by EEDI (Energy Efficiency Design Indicator) and EEOI (Energy Efficiency Operational Indicator). Ways to decrease the values of EEDI and EEOI in the ship energy effectiveness management have been shown. Consequences of replacing marine fuels with LNG for running auxiliary ship boilers have been considered thoroughly, taking into account ecological, constructional, operational, procedural and logistic limitations as well as economic consequences. The summary shows the influence of particular consequences of using LNG for running boilers on the methods of maintenance of auxiliary boilers.

  9. High-Temperature Behavior of a NiCr-Coated T91 Boiler Steel in the Platen Superheater of Coal-Fired Boiler

    NASA Astrophysics Data System (ADS)

    Chatha, Sukhpal Singh; Sidhu, Hazoor S.; Sidhu, Buta S.

    2013-06-01

    Ni-20Cr coating was deposited on T91 boiler tube steel by high-velocity oxy-fuel (HVOF) process to enhance high-temperature oxidation resistance. High-temperature performance of bare, as well as HVOF-coated steel specimens was evaluated for 1500 h under in the platen superheater zone of coal-fired boiler, where the temperature was around 900 °C. Experiments were carried out for 15 cycles, each of 100-h duration followed by 1-h cooling at ambient temperature. The extent of degradation of the specimens was assessed by the thickness loss and depth of internal corrosion attack. Ni-20Cr-coated steel performed better than the uncoated steel in actual boiler environment. The improved degradation resistance of Ni-20Cr coating can be attributed to the presence of Cr2O3 in the top oxide scale and dense microstructure.

  10. Co-firing switchgrass in a 50 MW pulverized coal boiler

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ragland, K.W.; Aerts, D.J.; Weiss, C.

    1996-12-31

    Switchgrass is being co-fired with pulverized coal in a 50 MW wall-fired, radiant boiler at MG&E`s Blount Street generating station. Shredded switchgrass is fed to a hammermill onto a live bottom storage bunker. Twin screw augers move the switchgrass onto a belt conveyor which leads to a rotary air lock valve and through a pressurized pipe to the boiler where it is injected into the furnace at two points between first and second level coal burners. The main objective of the project is to evaluate the boiler performance, slagging behavior, and emissions of the co-fired switchgrass at replacement of ratesmore » of up to 20% by mass (13% by heat input). Initial co-firing tests to examine fuel handling and feeding, combustion behavior, boiler response and emissions are favorable. In November a 100 hour co-fire test is planned.« less

  11. Coal-fired boiler houses in Cracow present state and possibilities to improve their efficiency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cyklis, P.; Butcher, T.A.

    1995-12-31

    A significant amount of heat energy both for heating and process purposes is generated in Cracow, Poland in small-and medium size local boiler houses. The operating procedure of these boiler houses is most often economically and ecologically ineffective because of the bad condition of boilers and lack of funds to install automation, control and measurement equipment. Within the Polish-American Program of Elimination of Low Emission Sources financed by the US Department of Energy, the ENERGOEKSPERT Co., Ltd. investigated chosen boiler houses in Cracow, commissioned by the Cracow Development Office. The results of these investigations were subject of engineering analysis carriedmore » out at the Institute of Industrial Equipment and Power Engineering, Technical University, Cracow. The analysis proved that the low-cost improvement of economic efficiency and reduction of air pollutant emission is feasible for combustion of coal fuels.« less

  12. Hydronic Heating Retrofits for Low-Rise Multifamily Buildings: Boiler Control Replacement and Monitoring

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dentz, J.; Henderson, H.; Varshney, K.

    2014-09-01

    The ARIES Collaborative, a U.S. Department of Energy Building America research team, partnered with NeighborWorks America affiliate Homeowners' Rehab Inc. (HRI) of Cambridge, Massachusetts, to study improvements to the central hydronic heating system in one of the nonprofit's housing developments. The heating controls in the three-building, 42-unit Columbia Cambridge Alliance for Spanish Tenants housing development were upgraded. Fuel use in the development was excessive compared to similar properties. A poorly insulated thermal envelope contributed to high energy bills, but adding wall insulation was not cost-effective or practical. The more cost-effective option was improving heating system efficiency. Efficient operation of themore » heating system faced several obstacles, including inflexible boiler controls and failed thermostatic radiator valves. Boiler controls were replaced with systems that offer temperature setbacks and one that controls heat based on apartment temperature in addition to outdoor temperature. Utility bill analysis shows that post-retrofit weather-normalized heating energy use was reduced by 10%-31% (average of 19%). Indoor temperature cutoff reduced boiler runtime (and therefore heating fuel consumption) by 28% in the one building in which it was implemented. Nearly all savings were obtained during night which had a lower indoor temperature cut off (68 degrees F) than day (73 degrees F). This implies that the outdoor reset curve was appropriately adjusted for this building for daytime operation. Nighttime setback of heating system supply water temperature had no discernable impact on boiler runtime or gas bills.« less

  13. Study of flame combustion of off-design binary coal blends in steam boilers

    NASA Astrophysics Data System (ADS)

    Kapustyanskii, A. A.

    2017-07-01

    Changes in the structure of the fuel consumption by the thermal power stations of Ukraine caused by failure in supplying anthracite from the Donets Basin are analyzed and the major tasks of maintaining the functioning of the coal industry are formulated. The possibility of using, in the near future, the flame combustion of off-design solid fuels in the power boilers of the thermal power plants and combined heat and power plants is studied. The article presents results of expert tests of the TPP-210A and TP-15 boilers under flame combustion of mixtures of anthracites, lean coal, and the coal from the RSA in various combinations. When combusting, such mixtures have higher values of the combustibles yield and the ash fusibility temperature. The existence of the synergetic effect in the flame combustion of binary coal blends with different degrees of metamorphism is discussed. A number of top-priority measures have been worked out that allow for switching over the boilers designed to be fired with anthracite to using blends of coals of different ranks. Zoned thermal analysis of the TP-15 boiler furnace was performed for numerical investigation of the temperature distribution between the furnace chamber zones and exploration of the possibility of the liquid slag disposal and the temperature conditions for realization of this process. A positive result was achieved by combusting anthracite culm (AC), the coal from the RSA, and their mixtures with lean coal within the entire range of the working loads of the boilers in question. The problems of normalization of the liquid slag flow were also successfully solved without closing the slag notch. The results obtained by balance experiments suggest that the characteristics of the flame combustion of a binary blend, i.e., the temperature conditions in the furnace, the support flame values, and the degree of the fuel burnout, are similar to the characteristics of the flame of the coal with a higher reactive capacity, which proves the existence of the synergetic effect in the processes of cocombustion of coals of various grades.

  14. Biofuel Pilot at St. Juliens Creek and Proposed NAVFAC Policy on Use of Biofuel In Heating Boilers

    DTIC Science & Technology

    2013-09-01

    Engineering and Expeditionary Warfare Center (NAVFAC EXWC) was tasked by NAVFAC HQ with facilitating a pilot study on the use of B20 Biodiesel (20...by NAVFAC HQ with facilitating a pilot study on the use of B20 Biodiesel (20 % biofuel mixed with 80 % fossil fuel oil hereafter referred to as B20...renewable) attributes of B20 as compared to conventional fossil fuel oil, and the ease of boiler and fuel system conversion to the biodiesel fuel

  15. Wood fueled boiler financial feasibility user's manual

    Treesearch

    Robert Govett; Scott Bowe; Terry Mace; Steve Hubbard; John (Rusty) Dramm; Richard Bergman

    2005-01-01

    “Wood Fueled Boiler Financial Feasibility” is a spreadsheet program designed for easy use on a personal computer. This program provides a starting point for interested parties to perform financial feasibility analysis of a steam boiler system for space heating or process heat. By allowing users to input the conditions applicable to their current or proposed fuel...

  16. 10. Interior, Boiler Room, Roundhouse Machine Shop Extension, Southern Pacific ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Interior, Boiler Room, Roundhouse Machine Shop Extension, Southern Pacific Railroad Carlin Shops, view to northwest (90mm lens). The silver stacks suspended from the ceiling in the background mark the former location of the boilers, and served as steam vents. - Southern Pacific Railroad, Carlin Shops, Roundhouse Machine Shop Extension, Foot of Sixth Street, Carlin, Elko County, NV

  17. 34. TOP O THE BOILER SHOWING CONSTRUCTION DETAILS. NOTE THE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    34. TOP O THE BOILER SHOWING CONSTRUCTION DETAILS. NOTE THE 1/2-INCH ROUND IRON REINFORCING ROD AND GALVANIZED FARM FENCING IN THE RIGHT FOREGROUND. AND THE EXPANDED METAL LATH WITH CEMENT COATING IN THE CEILING ABOVE THE BOILER. - Moravian Pottery & Tile Works, Southwest side of State Route 313 (Swamp Road), Northwest of East Court Street, Doylestown, Bucks County, PA

  18. 19. On salon deck level, view looking forward at tops ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    19. On salon deck level, view looking forward at tops of steam chimneys (rising from boilers) showing safety valves, safety valve vent pipe, and smoke bonnet underneath smokestack. Steam chimneys are integral parts of the boilers and in effect are smokestacks surrounded by a pressurized steam space continuous with the boiler steam spaces. - Ferry TICONDEROGA, Route 7, Shelburne, Chittenden County, VT

  19. 46 CFR 52.20-25 - Setting (modifies PFT-46).

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 2 2013-10-01 2013-10-01 false Setting (modifies PFT-46). 52.20-25 Section 52.20-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Requirements for Firetube Boilers § 52.20-25 Setting (modifies PFT-46). (a) The method of supporting firetube boilers shall be as indicated in PFT-46 of...

  20. 46 CFR 53.01-5 - Scope (modifies HG-100).

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Scope (modifies HG-100). 53.01-5 Section 53.01-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING HEATING BOILERS General Requirements § 53.01-5 Scope (modifies HG-100). (a) The regulations in this part apply to steam heating boilers, hot water boilers (which include...

Top