Ghost hunting—an assessment of ghost particle detection and removal methods for tomographic-PIV
NASA Astrophysics Data System (ADS)
Elsinga, G. E.; Tokgoz, S.
2014-08-01
This paper discusses and compares several methods, which aim to remove spurious peaks, i.e. ghost particles, from the volume intensity reconstruction in tomographic-PIV. The assessment is based on numerical simulations of time-resolved tomographic-PIV experiments in linear shear flows. Within the reconstructed volumes, intensity peaks are detected and tracked over time. These peaks are associated with particles (either ghosts or actual particles) and are characterized by their peak intensity, size and track length. Peak intensity and track length are found to be effective in discriminating between most ghosts and the actual particles, although not all ghosts can be detected using only a single threshold. The size of the reconstructed particles does not reveal an important difference between ghosts and actual particles. The joint distribution of peak intensity and track length however does, under certain conditions, allow a complete separation of ghosts and actual particles. The ghosts can have either a high intensity or a long track length, but not both combined, like all the actual particles. Removing the detected ghosts from the reconstructed volume and performing additional MART iterations can decrease the particle position error at low to moderate seeding densities, but increases the position error, velocity error and tracking errors at higher densities. The observed trends in the joint distribution of peak intensity and track length are confirmed by results from a real experiment in laminar Taylor-Couette flow. This diagnostic plot allows an estimate of the number of ghosts that are indistinguishable from the actual particles.
NASA Astrophysics Data System (ADS)
Ito, Juri; Kajikawa, Kotaro
2016-02-01
We propose a method to measure the variation of the molecular length of self-assembled monolayers (SAMs) when it is exposed to solutions at different pH conditions. The surface immobilized gold nanospheres (SIGNs) shows strong absorption peak at the wavelengths of 600-800 nm when p-polarized light is illuminated. The peak wavelength depends on the length of the gap distance between the SIGNs and the substrate. The gap is supported by the SAM molecules. According to the analytical calculation based on multiple expansion, the relation between the peak wavelength of the SIGN structures and the gap distance is calculated, to evaluate the molecular length of the SAM through the optical absorption spectroscopy for the SIGN structures. The molecular length of the SIGN structure was measured in air, water, acidic, and basic solutions. It was found that the molecular lengths are longer in acidic solutions.
Vehicle Speed and Length Estimation Using Data from Two Anisotropic Magneto-Resistive (AMR) Sensors
Markevicius, Vytautas; Navikas, Dangirutis; Valinevicius, Algimantas; Zilys, Mindaugas
2017-01-01
Methods for estimating a car’s length are presented in this paper, as well as the results achieved by using a self-designed system equipped with two anisotropic magneto-resistive (AMR) sensors, which were placed on a road lane. The purpose of the research was to compare the lengths of mid-size cars, i.e., family cars (hatchbacks), saloons (sedans), station wagons and SUVs. Four methods were used in the research: a simple threshold based method, a threshold method based on moving average and standard deviation, a two-extreme-peak detection method and a method based on the amplitude and time normalization using linear extrapolation (or interpolation). The results were achieved by analyzing changes in the magnitude and in the absolute z-component of the magnetic field as well. The tests, which were performed in four different Earth directions, show differences in the values of estimated lengths. The magnitude-based results in the case when cars drove from the South to the North direction were even up to 1.2 m higher than the other results achieved using the threshold methods. Smaller differences in lengths were observed when the distances were measured between two extreme peaks in the car magnetic signatures. The results were summarized in tables and the errors of estimated lengths were presented. The maximal errors, related to real lengths, were up to 22%. PMID:28771171
[Study of Determination of Oil Mixture Components Content Based on Quasi-Monte Carlo Method].
Wang, Yu-tian; Xu, Jing; Liu, Xiao-fei; Chen, Meng-han; Wang, Shi-tao
2015-05-01
Gasoline, kerosene, diesel is processed by crude oil with different distillation range. The boiling range of gasoline is 35 ~205 °C. The boiling range of kerosene is 140~250 °C. And the boiling range of diesel is 180~370 °C. At the same time, the carbon chain length of differentmineral oil is different. The carbon chain-length of gasoline is within the scope of C7 to C11. The carbon chain length of kerosene is within the scope of C12 to C15. And the carbon chain length of diesel is within the scope of C15 to C18. The recognition and quantitative measurement of three kinds of mineral oil is based on different fluorescence spectrum formed in their different carbon number distribution characteristics. Mineral oil pollution occurs frequently, so monitoring mineral oil content in the ocean is very important. A new method of components content determination of spectra overlapping mineral oil mixture is proposed, with calculation of characteristic peak power integrationof three-dimensional fluorescence spectrum by using Quasi-Monte Carlo Method, combined with optimal algorithm solving optimum number of characteristic peak and range of integral region, solving nonlinear equations by using BFGS(a rank to two update method named after its inventor surname first letter, Boyden, Fletcher, Goldfarb and Shanno) method. Peak power accumulation of determined points in selected area is sensitive to small changes of fluorescence spectral line, so the measurement of small changes of component content is sensitive. At the same time, compared with the single point measurement, measurement sensitivity is improved by the decrease influence of random error due to the selection of points. Three-dimensional fluorescence spectra and fluorescence contour spectra of single mineral oil and the mixture are measured by taking kerosene, diesel and gasoline as research objects, with a single mineral oil regarded whole, not considered each mineral oil components. Six characteristic peaks are selected for characteristic peak power integration to determine components content of mineral oil mixture of gasoline, kerosene and diesel by optimal algorithm. Compared with single point measurement of peak method and mean method, measurement sensitivity is improved about 50 times. The implementation of high precision measurement of mixture components content of gasoline, kerosene and diesel provides a practical algorithm for components content direct determination of spectra overlapping mixture without chemical separation.
The effects of age and step length on joint kinematics and kinetics of large out-and-back steps
Schulz, Brian W.; Ashton-Miller, James A.; Alexander, Neil B.
2008-01-01
Background Maximum Step Length is a clinical test that has been shown to correlate with age, various measures of fall risk, and knee and hip joint extension speed, strength, and power capacities, but little is known about the kinematics and kinetics of the large out-and-back step utilized. Methods Body motions and ground reaction forces were recorded for 11 unimpaired younger and 10 older women while attaining Maximum Step Length. Joint kinematics and kinetics were calculated using inverse dynamics. The effects of age group and step length on the biomechanics of these large out-and-back steps were determined. Findings Maximum Step Length was 40% greater in the younger than in the older women (p<0.0001). Peak knee and hip, but not ankle, angle, velocity, moment, and power were generally greater for younger women and longer steps. After controlling for age group, step length generally explained significant additional variance in hip and torso kinematics and kinetics (incremental R2=0.09–0.37). The young reached their peak knee extension moment immediately after landing of the step out, while the old reached their peak knee extension moment just before the return step lift off (p=0.03). Interpretation Maximum Step Length is strongly associated with hip kinematics and kinetics. Delays in peak knee extension moment that appear to be unrelated to step length, may indicate a reduced ability of older women to rapidly apply force to the ground with the stepping leg and thus arrest the momentum of a fall. PMID:18308435
Bisese, James A.
1995-01-01
Methods are presented for estimating the peak discharges of rural, unregulated streams in Virginia. A Pearson Type III distribution is fitted to the logarithms of the unregulated annual peak-discharge records from 363 stream-gaging stations in Virginia to estimate the peak discharge at these stations for recurrence intervals of 2 to 500 years. Peak-discharge characteristics for 284 unregulated stations are divided into eight regions based on physiographic province, and regressed on basin characteristics, including drainage area, main channel length, main channel slope, mean basin elevation, percentage of forest cover, mean annual precipitation, and maximum rainfall intensity. Regression equations for each region are computed by use of the generalized least-squares method, which accounts for spatial and temporal correlation between nearby gaging stations. This regression technique weights the significance of each station to the regional equation based on the length of records collected at each cation, the correlation between annual peak discharges among the stations, and the standard deviation of the annual peak discharge for each station.Drainage area proved to be the only significant explanatory variable in four regions, while other regions have as many as three significant variables. Standard errors of the regression equations range from 30 to 80 percent. Alternate equations using drainage area only are provided for the five regions with more than one significant explanatory variable.Methods and sample computations are provided to estimate peak discharges at gaged and engaged sites in Virginia for recurrence intervals of 2, 5, 10, 25, 50, 100, 200, and 500 years, and to adjust the regression estimates for sites on gaged streams where nearby gaging-station records are available.
Allan, Richard; Woodburn, James; Telfer, Scott; Abbott, Mandy; Steultjens, Martijn Pm
2017-06-01
The knee adduction moment is consistently used as a surrogate measure of medial compartment loading. Foot orthoses are designed to reduce knee adduction moment via lateral wedging. The 'dose' of wedging required to optimally unload the affected compartment is unknown and variable between individuals. This study explores a personalised approach via three-dimensional printed foot orthotics to assess the biomechanical response when two design variables are altered: orthotic length and lateral wedging. Foot orthoses were created for 10 individuals with symptomatic medial knee osteoarthritis and 10 controls. Computer-aided design software was used to design four full and four three-quarter-length foot orthoses per participant each with lateral posting of 0° 'neutral', 5° rearfoot, 10° rearfoot and 5° forefoot/10° rearfoot. Three-dimensional printers were used to manufacture all foot orthoses. Three-dimensional gait analyses were performed and selected knee kinetics were analysed: first peak knee adduction moment, second peak knee adduction moment, first knee flexion moment and knee adduction moment impulse. Full-length foot orthoses provided greater reductions in first peak knee adduction moment (p = 0.038), second peak knee adduction moment (p = 0.018) and knee adduction moment impulse (p = 0.022) compared to three-quarter-length foot orthoses. Dose effect of lateral wedging was found for first peak knee adduction moment (p < 0.001), second peak knee adduction moment (p < 0.001) and knee adduction moment impulse (p < 0.001) indicating greater unloading for higher wedging angles. Significant interaction effects were found for foot orthosis length and participant group in second peak knee adduction moment (p = 0.028) and knee adduction moment impulse (p = 0.036). Significant interaction effects were found between orthotic length and wedging condition for second peak knee adduction moment (p = 0.002). No significant changes in first knee flexion moment were found. Individual heterogeneous responses to foot orthosis conditions were observed for first peak knee adduction moment, second peak knee adduction moment and knee adduction moment impulse. Biomechanical response is highly variable with personalised foot orthoses. Findings indicate that the tailoring of a personalised intervention could provide an additional benefit over standard interventions and that a three-dimensional printing approach to foot orthosis manufacturing is a viable alternative to the standard methods.
Estimation of the vortex length scale and intensity from two-dimensional samples
NASA Technical Reports Server (NTRS)
Reuss, D. L.; Cheng, W. P.
1992-01-01
A method is proposed for estimating flow features that influence flame wrinkling in reciprocating internal combustion engines, where traditional statistical measures of turbulence are suspect. Candidate methods were tested in a computed channel flow where traditional turbulence measures are valid and performance can be rationally evaluated. Two concepts are tested. First, spatial filtering is applied to the two-dimensional velocity distribution and found to reveal structures corresponding to the vorticity field. Decreasing the spatial-frequency cutoff of the filter locally changes the character and size of the flow structures that are revealed by the filter. Second, vortex length scale and intensity is estimated by computing the ensemble-average velocity distribution conditionally sampled on the vorticity peaks. The resulting conditionally sampled 'average vortex' has a peak velocity less than half the rms velocity and a size approximately equal to the two-point-correlation integral-length scale.
The pattern of facial skeletal growth and its relationship to various common indexes of maturation.
Mellion, Zachary J; Behrents, Rolf G; Johnston, Lysle E
2013-06-01
Sequential stages in the development of the hand, wrist, and cervical vertebrae commonly are used to assess maturation and predict the timing of the adolescent growth spurt. This approach is predicated on the idea that forecasts based on skeletal age must, of necessity, be superior to those based on chronologic age. This study was undertaken to test this reasonable, albeit largely unproved, assumption in a large, longitudinal sample. Serial records of 100 children (50 girls, 50 boys) were chosen from the files of the Bolton-Brush Growth Study Center in Cleveland, Ohio. The 100 series were 6 to 11 years in length, a span that was designed to encompass the onset and the peak of the adolescent facial growth spurt in each subject. Five linear cephalometric measurements (S-Na, Na-Me, PNS-A, S-Go, Go-Pog) were summed to characterize general facial size; a sixth (Co-Gn) was used to assess mandibular length. In all, 864 cephalograms were traced and analyzed. For most years, chronologic age, height, and hand-wrist films were available, thereby permitting various alternative methods of maturational assessment and prediction to be tested. The hand-wrist and the cervical vertebrae films for each time point were staged. Yearly increments of growth for stature, face, and mandible were calculated and plotted against chronologic age. For each subject, the actual age at onset and peak for stature and facial and mandibular size served as the gold standards against which key ages inferred from other methods could be compared. On average, the onset of the pubertal growth spurts in height, facial size, and mandibular length occurred in girls at 9.3, 9.8, and 9.5 years, respectively. The difference in timing between height and facial size growth spurts was statistically significant. In boys, the onset for height, facial size, and mandibular length occurred more or less simultaneously at 11.9, 12.0, and 11.9 years, respectively. In girls, the peak of the growth spurt in height, facial size, and mandibular length occurred at 10.9, 11.5, and 11.5 years. Height peaked significantly earlier than both facial size and mandibular length. In boys, the peak in height occurred slightly (but statistically significantly) earlier than did the peaks in the face and mandible: 14.0, 14.4, and 14.3 years. Based on rankings, the hand-wrist stages provided the best indication (lowest root mean squared error) that maturation had advanced to the peak velocity stage. Chronologic age, however, was nearly as good, whereas the vertebral stages were consistently the worst. Errors from the use of statural onset to predict the peak of the pubertal growth spurt in height, facial size, and mandibular length were uniformly lower than for predictions based on the cervical vertebrae. Chronologic age, especially in boys, was a close second. The common assumption that onset and peak occur at ages 12 and 14 years in boys and 10 and 12 years in girls seems correct for boys, but it is 6 months to 1 year late for girls. As an index of maturation, hand-wrist skeletal ages appear to offer the best indication that peak growth velocity has been reached. Of the methods tested here for the prediction of the timing of peak velocity, statural onset had the lowest errors. Although mean chronologic ages were nearly as good, stature can be measured repeatedly and thus might lead to improved prediction of the timing of the adolescent growth spurt. Copyright © 2013 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
1,4-Bis(2-methylstyryl)benzene doped PMMA fibre for blue range fluorescent applications
NASA Astrophysics Data System (ADS)
Miluski, Piotr; Kochanowicz, Marcin; Zmojda, Jacek; Dorosz, Dominik
2018-03-01
The fluorescent dyes allow new optical applications in polymer-based optical fibre technology. The article presents highly fluorescent 1,4-Bis(2-methylstyryl)benzene doped poly(methyl methacrylate) (PMMA) fibre. The multi-peak (422, 450, 488 nm) fluorescence spectrum of the bulk specimen under 355 nm excitation is presented. The polymerization and fibre drawing process is also shown. The fluorescent properties vs. fibre length at excitation 405 nm are investigated. Significant spectrum shape changes and red shift phenomena of individual peaks are presented using one end excitation and fibre cutting method measurements for fibre length 2-90 cm. Obtained attenuation level 0.69 dB/m limits useful fibre length but obtained results can be useful in new polymeric fibers applications (e.g. sensors, light sources).
Wang, Hua; Zeng, Deping; Chen, Ziguang; Yang, Zengtao
2017-04-12
Based on the acousto-optic interaction, we propose a laser deflection method for rapidly, non-invasively and quantitatively measuring the peak positive pressure of HIFU fields. In the characterization of HIFU fields, the effect of nonlinear propagation is considered. The relation between the laser deflection length and the peak positive pressure is derived. Then the laser deflection method is assessed by comparing it with the hydrophone method. The experimental results show that the peak positive pressure measured by laser deflection method is little higher than that obtained by the hydrophone, confirming that they are in reasonable agreement. Considering that the peak pressure measured by hydrophones is always underestimated, the laser deflection method is assumed to be more accurate than the hydrophone method due to the absence of the errors in hydrophone spatial-averaging measurement and the influence of waveform distortion on hydrophone corrections. Moreover, noting that the Lorentz formula still remains applicable to high-pressure environments, the laser deflection method exhibits a great potential for measuring HIFU field under high-pressure amplitude. Additionally, the laser deflection method provides a rapid way for measuring the peak positive pressure, without the scan time, which is required by the hydrophones.
Pullout Performances of Grouted Rockbolt Systems with Bond Defects
NASA Astrophysics Data System (ADS)
Xu, Chang; Li, Zihan; Wang, Shanyong; Wang, Shuren; Fu, Lei; Tang, Chunan
2018-03-01
This paper presents a numerical study on the pullout behaviour of fully grouted rockbolts with bond defects. The cohesive zone model (CZM) is adopted to model the bond-slip behaviour between the rockbolt and grout material. Tensile tests were also conducted to validate the numerical model. The results indicate that the defect length can obviously influence the load and stress distributions along the rockbolt as well as the load-displacement response of the grouted system. Moreover, a plateau in the stress distribution forms due to the bond defect. The linear limit and peak load of the load-displacement response decrease as the defect length increases. A bond defect located closer to the loaded end leads to a longer nonlinear stage in the load-displacement response. However, the peak loads measured from the specimens made with various defect locations are almost approximately the same. The peak load for a specimen with the defects equally spaced along the bolt is higher than that for a specimen with defects concentrated in a certain zone, even with the same total defect length. Therefore, the dispersed pattern of bond defects would be much safer than the concentrated pattern. For the specimen with dispersed defects, the peak load increases with an increase in the defect spacing, even if the total defect length is the same. The peak load for a grouted rockbolt system with defects increases with an increases in the bolt diameter. This work leads to a better understanding of the load transfer mechanism for grouted rockbolt systems with bond defects, and paves the way towards developing a general evaluation method for damaged rockbolt grouted systems.
NASA Technical Reports Server (NTRS)
Krull, H George; Beale, William T
1956-01-01
Internal performance data on a short exhaust nozzle designed by the method of characteristics were obtained over a range of pressure ratios from 1.5 to 22. The peak thrust coefficient was not affected by a shortened divergent section, but it occurred at lower pressure ratios due to reduction in expansion ratio. This nozzle contour based on characteristics solution gave higher thrust coefficients than a conical convergent-divergent nozzle of equivalent length. Abrupt-inlet sections permitted a reduction in nozzle length without a thrust-coefficient reduction.
Heart Electrical Actions as Biometric Indicia
NASA Technical Reports Server (NTRS)
Schipper, John F. (Inventor); Dusan, Sorin V. (Inventor); Jorgensen, Charles C. (Inventor); Belousof, Eugene (Inventor)
2013-01-01
A method and associated system for use of statistical parameters based on peak amplitudes and/or time interval lengths and/or depolarization-repolarization vector angles and/or depolarization-repolarization vector lengths for PQRST electrical signals associated with heart waves, to identify a person. The statistical parameters, estimated to be at least 192, serve as biometric indicia, to authenticate, or to decline to authenticate, an asserted identity of a candidate person.
Khoo, E H; Ahmed, I; Goh, R S M; Lee, K H; Hung, T G G; Li, E P
2013-03-11
The dynamic-thermal electron-quantum medium finite-difference time-domain (DTEQM-FDTD) method is used for efficient analysis of mode profile in elliptical microcavity. The resonance peak of the elliptical microcavity is studied by varying the length ratio. It is observed that at some length ratios, cavity mode is excited instead of whispering gallery mode. This depicts that mode profiles are length ratio dependent. Through the implementation of the DTEQM-FDTD on graphic processing unit (GPU), the simulation time is reduced by 300 times as compared to the CPU. This leads to an efficient optimization approach to design microcavity lasers for wide range of applications in photonic integrated circuits.
40 CFR 1065.275 - N2O measurement devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... for interpretation of infrared spectra. For example, EPA Test Method 320 is considered a valid method... and length to achieve adequate resolution of the N2O peak for analysis. Examples of acceptable columns....550(b) that would otherwise apply. For example, you may perform a span gas measurement before and...
40 CFR 1065.275 - N2O measurement devices.
Code of Federal Regulations, 2011 CFR
2011-07-01
... for interpretation of infrared spectra. For example, EPA Test Method 320 is considered a valid method... and length to achieve adequate resolution of the N2O peak for analysis. Examples of acceptable columns....550(b) that would otherwise apply. For example, you may perform a span gas measurement before and...
Long-period fiber grating fabricated by 800 nm femtosecond laser pulses
NASA Astrophysics Data System (ADS)
Zhang, Yani; Xi, Yaru; Liu, Sicong; Jiang, Peng; Zhao, Ya; Xu, Qiang
2018-02-01
In this paper, the long period fiber gratings (LPFGs) in standard SMF-28 telecommunication fibers without hydrogen loading were inscribed by using point-to-point direct writing method of femtosecond laser pulses with pulse duration of 100 fs, repetition rate of 1kHz and a central wavelength of 800 nm. The LPFGs with different spectral characteristics were fabricated by adjusting grating period, grating length and duty ratio. The results show that the resonant peak wavelengths shift to the long-wave direction with the increase of the grating length increasing. The variations of duty ratio will lead to the generation of resonance rejection band of LPFGs from singlepeak to multi-peak plus lesser out-of-band loss.
The visible extinction peaks of Ag nanohelixes: A periodic effective dipole model
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Z.-Y.; Zhao, Y.-P.
2011-02-21
Using the discrete dipole approximation method, two visible extinction peaks are found for Ag nanohelixes. Both of them redshift periodically in an approximate half pitch with the helix height and redshift linearly with the helix diameter and pitch height. At the two absorbance peaks, an integer number of E-field maxima occur along the helix. These field maxima could be treated as results of collective electron oscillations by periodic effective dipoles within a half pitch along the helix. The wavelengths of the absorbance peaks are found to scale with the effective dipole length, which is consistent with the periodic structure ofmore » the helix.« less
Cardador, D; Segura, D; Rodríguez, A
2018-02-19
In this paper, we report the benefits of working with photonic molecules in macroporous silicon photonic crystals. In particular, we theoretically and experimentally demonstrate that the optical properties of a resonant peak produced by a single photonic atom of 2.6 µm wide can be sequentially improved if a second and a third cavity of the same length are introduced in the structure. As a consequence of that, the base of the peak is reduced from 500 nm to 100 nm, while its amplitude remains constant, increasing its Q-factor from its initial value of 25 up to 175. In addition, the bandgap is enlarged almost twice and the noise within it is mostly eliminated. In this study we also provide a way of reducing the amplitude of one or two peaks, depending whether we are in the two- or three-cavity case, by modifying the length of the involved photonic molecules so that the remainder can be used to measure gas by spectroscopic methods.
The Lumbar Lordosis in Males and Females, Revisited
Hay, Ori; Dar, Gali; Abbas, Janan; Stein, Dan; May, Hila; Masharawi, Youssef; Peled, Nathan; Hershkovitz, Israel
2015-01-01
Background Whether differences exist in male and female lumbar lordosis has been debated by researchers who are divided as to the nature of variations in the spinal curve, their origin, reasoning, and implications from a morphological, functional and evolutionary perspective. Evaluation of the spinal curvature is constructive in understanding the evolution of the spine, as well as its pathology, planning of surgical procedures, monitoring its progression and treatment of spinal deformities. The aim of the current study was to revisit the nature of lumbar curve in males and females. Methods Our new automated method uses CT imaging of the spine to measure lumbar curvature in males and females. The curves extracted from 158 individuals were based on the spinal canal, thus avoiding traditional pitfalls of using bone features for curve estimation. The model analysis was carried out on the entire curve, whereby both local and global descriptors were examined in a single framework. Six parameters were calculated: segment length, curve length, curvedness, lordosis peak location, lordosis cranial peak height, and lordosis caudal peak height. Principal Findings Compared to males, the female spine manifested a statistically significant greater curvature, a caudally located lordotic peak, and greater cranial peak height. As caudal peak height is similar for males and females, the illusion of deeper lordosis among females is due partially to the fact that the upper part of the female lumbar curve is positioned more dorsally (more backwardly inclined). Conclusions Males and females manifest different lumbar curve shape, yet similar amount of inward curving (lordosis). The morphological characteristics of the female spine were probably developed to reduce stress on the vertebral elements during pregnancy and nursing. PMID:26301782
NASA Astrophysics Data System (ADS)
Shen, Ji-Mei; Liu, Jing; Min, Yi; Zhou, Li-Ping
2016-12-01
Using the first-principles method which combines the nonequilibrium Green’s function (NEGF) with density functional theory (DFT), the role of defect, dopant, barrier length and geometric deformation for low-bias negative differential resistance (NDR) in two capped armchair carbon nanotubes (CNTs) sandwiching σ barrier are systematically analyzed. We found that this method can regulate the negative differential resistance (NDR) effects such as current peak and peak position. The adjusting mechanism may originate from orbital interaction and orbital reconstruction. Our calculations try to manipulate the transport characteristics in energy space by simply manipulating the structure in real space, which may promise the potential applications in nanomolecular-electronics in the future.
Noninvasive Uterine Electromyography For Prediction of Preterm Delivery*
UCOVNIK, Miha L; MANER, William L.; CHAMBLISS, Linda R.; BLUMRICK, Richard; BALDUCCI, James; NOVAK-ANTOLIC, Ziva; GARFIELD, Robert E.
2011-01-01
Objective Power spectrum (PS) of uterine electromyography (EMG) can identify true labor. EMG propagation velocity (PV) to diagnose labor has not been reported. The objective was to compare uterine EMG against current methods to predict preterm delivery. Study design EMG was recorded in 116 patients (preterm labor, n=20; preterm non-labor, n=68; term labor, n=22; term non-labor, n=6). Student’s t-test was used to compare EMG values for labor vs. non-labor (P<0.05 significant). Predictive values of EMG, Bishop-score, contractions on tocogram, and transvaginal cervical length were calculated using receiver-operator-characteristics analysis. Results PV was higher in preterm and term labor compared with non-labor (P<0.001). Combined PV and PS peak frequency predicted preterm delivery within 7 days with area-under-the-curve (AUC) = 0.96. Bishop score, contractions, and cervical length had AUC of 0.72, 0.67, and 0.54. Conclusions Uterine EMG PV and PS peak frequency more accurately identify true preterm labor than clinical methods. PMID:21145033
Gürkan Figen, Ziya; Aytür, Orhan; Arıkan, Orhan
2016-03-20
In this paper, we design aperiodic gratings based on orientation-patterned gallium arsenide (OP-GaAs) for converting 2.1 μm pump laser radiation into long-wave infrared (8-12 μm) in an idler-efficiency-enhanced scheme. These single OP-GaAs gratings placed in an optical parametric oscillator (OPO) or an optical parametric generator (OPG) can simultaneously phase match two optical parametric amplification (OPA) processes, OPA 1 and OPA 2. We use two design methods that allow simultaneous phase matching of two arbitrary χ(2) processes and also free adjustment of their relative strength. The first aperiodic grating design method (Method 1) relies on generating a grating structure that has domain walls located at the zeros of the summation of two cosine functions, each of which has a spatial frequency that equals one of the phase-mismatch terms of the two processes. Some of the domain walls are discarded considering the minimum domain length that is achievable in the production process. In this paper, we propose a second design method (Method 2) that relies on discretizing the crystal length with sample lengths that are much smaller than the minimum domain length and testing each sample's contribution in such a way that the sign of the nonlinearity maximizes the magnitude sum of the real and imaginary parts of the Fourier transform of the grating function at the relevant phase mismatches. Method 2 produces a similar performance as Method 1 in terms of the maximization of the height of either Fourier peak located at the relevant phase mismatch while allowing an adjustable relative height for the two peaks. To our knowledge, this is the first time that aperiodic OP-GaAs gratings have been proposed for efficient long-wave infrared beam generation based on simultaneous phase matching.
Georgakarakos, Efstratios; Xenakis, Antonios; Georgiadis, George S
2018-02-01
We conducted a computational study to assess the hemodynamic impact of variant main body-to-iliac limb length (L1/L2) ratios on certain hemodynamic parameters acting on the endograft (EG) either on the normal bifurcated (Bif) or the cross-limb (Cx) fashion. A customary bifurcated 3D model was computationally created and meshed using the commercially available ANSYS ICEM (Ansys Inc., Canonsburg, PA, USA) software. The total length of the EG, was kept constant, while the L1/L2 ratio ranged from 0.3 to 1.5 in the Bif and Cx reconstructed EG models. The compliance of the graft was modeled using a Fluid Structure Interaction method. Important hemodynamic parameters such as pressure drop along EG, wall shear stress (WSS) and helicity were calculated. The greatest pressure decrease across EG was calculated in the peak systolic phase. With increasing L1/L2 it was found that the Pressure Drop was increasing for the Cx configuration, while decreasing for the Bif. The greatest helicity (4.1 m/s2) was seen in peak systole of Cx with ratio of 1.5 whereas its greatest value (2 m/s2) was met in peak systole in the Bif with the shortest L1/L2 ratio (0.3). Similarly, the maximum WSS value was highest (2.74Pa) in the peak systole for the 1.5 L1/L2 of the Cx configuration, while the maximum WSS value equaled 2 Pa for all length ratios of the Bif modification (with the WSS found for L1/L2=0.3 being marginally higher). There was greater discrepancy in the WSS values for all L1/L2 ratios of the Cx bifurcation compared to Bif. Different L1/L2 rations are shown to have an impact on the pressure distribution along the entire EG while the length ratio predisposing to highest helicity or WSS values is also determined by the iliac limbs pattern of the EG. Since current custom-made EG solutions can reproduce variability in main-body/iliac limbs length ratios, further computational as well as clinical research is warranted to delineate and predict the hemodynamic and clinical effect of variable length ratios.
SENSITIVITY OF STRUCTURAL RESPONSE TO GROUND MOTION SOURCE AND SITE PARAMETERS.
Safak, Erdal; Brebbia, C.A.; Cakmak, A.S.; Abdel Ghaffar, A.M.
1985-01-01
Designing structures to withstand earthquakes requires an accurate estimation of the expected ground motion. While engineers use the peak ground acceleration (PGA) to model the strong ground motion, seismologists use physical characteristics of the source and the rupture mechanism, such as fault length, stress drop, shear wave velocity, seismic moment, distance, and attenuation. This study presents a method for calculating response spectra from seismological models using random vibration theory. It then investigates the effect of various source and site parameters on peak response. Calculations are based on a nonstationary stochastic ground motion model, which can incorporate all the parameters both in frequency and time domains. The estimation of the peak response accounts for the effects of the non-stationarity, bandwidth and peak correlations of the response.
Constructing Current Singularity in a 3D Line-tied Plasma
Zhou, Yao; Huang, Yi-Min; Qin, Hong; ...
2017-12-27
We revisit Parker's conjecture of current singularity formation in 3D line-tied plasmas using a recently developed numerical method, variational integration for ideal magnetohydrodynamics in Lagrangian labeling. With the frozen-in equation built-in, the method is free of artificial reconnection, and hence it is arguably an optimal tool for studying current singularity formation. Using this method, the formation of current singularity has previously been confirmed in the Hahm–Kulsrud–Taylor problem in 2D. In this paper, we extend this problem to 3D line-tied geometry. The linear solution, which is singular in 2D, is found to be smooth for arbitrary system length. However, with finitemore » amplitude, the linear solution can become pathological when the system is sufficiently long. The nonlinear solutions turn out to be smooth for short systems. Nonetheless, the scaling of peak current density versus system length suggests that the nonlinear solution may become singular at finite length. Finally, with the results in hand, we can neither confirm nor rule out this possibility conclusively, since we cannot obtain solutions with system length near the extrapolated critical value.« less
Schiereck, P; de Beer, E L; Grundeman, R L; Manussen, T; Kylstra, N; Bras, W
1992-10-01
Single skinned skeletal muscle fibres were immersed in solutions containing two different levels of activator calcium (pCa: 4.4; 6.0). Sarcomere length was varied from 1.6 to 3.5 microns and recorded by laser diffraction. Slack length was 2.0 microns. Small-angle equatorial X-ray diffraction patterns of relaxed and activated fibres at different sarcomere lengths were recorded using synchrotron radiation. The position and amplitude of the diffraction peaks were calculated from the spectra based on the hexagonal arrangement of the myofilament matrix, relating the position of the (1.0)- and (1.1)-diffraction peaks in this model by square root of 3. The diffraction peaks were fitted by five Gaussian functions (1.0, 1.1, 2.0, 2.1 and Z-line) and residual background was corrected by means of a hyperbola. The coupling of the position of the (1.0)- and (1.1)-peak was expressed as a factor: FAC = [d(1.0)/d(1.1)]/square root 3. In the relaxed state this coupling factor decreased at increasing sarcomere length (0.9880 +/- 0.002 at 2.0 microns; 0.900 +/- 0.01 at 3.5 microns). The coupling factor tends toward the one that will be obtained from the squared structure of actin filaments near the Z-discs. At shorter sarcomere lengths a decrease of the coupling factor has also been seen (0.9600 +/- 0.005 at 1.6 microns), giving rise to an increased uniform deformation of the hexagonal matrix, when sarcomere length is changed from slack length. From these experiments we conclude that a change in sarcomere length (from slack length) increases the deformation of the actin-myosin matrix to a tetragonal lattice.
Inherent length-scales of periodic solar wind number density structures
NASA Astrophysics Data System (ADS)
Viall, N. M.; Kepko, L.; Spence, H. E.
2008-07-01
We present an analysis of the radial length-scales of periodic solar wind number density structures. We converted 11 years (1995-2005) of solar wind number density data into radial length series segments and Fourier analyzed them to identify all spectral peaks with radial wavelengths between 72 (116) and 900 (900) Mm for slow (fast) wind intervals. Our window length for the spectral analysis was 9072 Mm, approximately equivalent to 7 (4) h of data for the slow (fast) solar wind. We required that spectral peaks pass both an amplitude test and a harmonic F-test at the 95% confidence level simultaneously. From the occurrence distributions of these spectral peaks for slow and fast wind, we find that periodic number density structures occur more often at certain radial length-scales than at others, and are consistently observed within each speed range over most of the 11-year interval. For the slow wind, those length-scales are L ˜ 73, 120, 136, and 180 Mm. For the fast wind, those length-scales are L ˜ 187, 270 and 400 Mm. The results argue for the existence of inherent radial length-scales in the solar wind number density.
Gritti, Fabrice; Guiochon, Georges
2011-02-18
The peak parking (PP) method probes the longitudinal diffusion coefficient of a compound at a single location along the chromatographic column. We extended to a so-called multi-location peak parking (MLPP) method, in which a large number of axial locations along the column are selected in order to check the validity of the conventional PP method and to reveal possible defaults in the structure of the packed bed or pitfalls of the PP and the MLPP methods. MLPP was applied to a series of HILIC columns, including a 5.0 μm Venusil, a 3.0 μm Luna-diol, three 2.7 μm Halo, and a 1.7 μm Kinetex columns. The results demonstrate that the MLPP method may reveal local heterogeneities in the axial diffusion of small retained low molecular weight compounds along the column. Most importantly, experiments show that the sample zone should not be parked in the entrance of the column (i.e., at <1/10 th of the column length). The abrupt drop in the flow rate considerably affects the peak shape and prevents scientists from using the conventional PP method. Practical solutions to cope with that problem are proposed and their success/failure are discussed. Copyright © 2010 Elsevier B.V. All rights reserved.
Phillips, Rebecca Sellin; Wheaton, Catharine J
2008-07-01
The objective of this study was to determine if sexual swellings in mandrills (Mandrillus sphinx) are a reflection of reproductive endocrine state. Urine samples were assayed using an enzyme immunoassay measuring pregnanediol-3-glucuronide (PdG) and estrone conjugates (E(1)C). Hormone patterns of ovarian cycles, pregnancy and lactation were characterized and compared with sexual swellings and copulations relative to menses and peak E(1)C. Cycle lengths averaging 28.7 days and pregnancy length of 181 days determined by hormonal and sexual swelling measures were similar to those reported in other Old World primate species. First day of copulation was observed during rising E(1)C concentrations and preceded observations of peak swelling by 1-2 days. Observations of peak sexual swellings occurred at or on the day after peak E(1)C and decreased following the ovulatory increase in PdG. Observations of menses and sexual swellings are a useful method to track mandrill ovarian cycles and can assist zoos in determining the reproductive state of females in their collections. Zoo Biol 27:320-330, 2008. (c) 2008 Wiley-Liss, Inc.
Gas Chromatograph Method Optimization Trade Study for RESOLVE: 20-meter Column v. 8-meter Column
NASA Technical Reports Server (NTRS)
Huz, Kateryna
2014-01-01
RESOLVE is the payload on a Class D mission, Resource Prospector, which will prospect for water and other volatile resources at a lunar pole. The RESOLVE payload's primary scientific purpose includes determining the presence of water on the moon in the lunar regolith. In order to detect the water, a gas chromatograph (GC) will be used in conjunction with a mass spectrometer (MS). The goal of the experiment was to compare two GC column lengths and recommend which would be best for RESOLVE's purposes. Throughout the experiment, an Inficon Fusion GC and an Inficon Micro GC 3000 were used. The Fusion had a 20m long column with 0.25mm internal diameter (Id). The Micro GC 3000 had an 8m long column with a 0.32mm Id. By varying the column temperature and column pressure while holding all other parameters constant, the ideal conditions for testing with each column length in their individual instrument configurations were determined. The criteria used for determining the optimal method parameters included (in no particular order) (1) quickest run time, (2) peak sharpness, and (3) peak separation. After testing numerous combinations of temperature and pressure, the parameters for each column length that resulted in the most optimal data given my three criteria were selected. The ideal temperature and pressure for the 20m column were 95 C and 50psig. At this temperature and pressure, the peaks were separated and the retention times were shorter compared to other combinations. The Inficon Micro GC 3000 operated better at lower temperature mainly due to the shorter 8m column. The optimal column temperature and pressure were 70 C and 30psig. The Inficon Micro GC 3000 8m column had worse separation than the Inficon Fusion 20m column, but was able to separate water within a shorter run time. Therefore, the most significant tradeoff between the two column lengths was peak separation of the sample versus run time. After performing several tests, it was concluded that better detection via good peak separation with a longer run time is a better asset than moderate peak separation with a shorter run time. Even given that RESOLVE is highly interested in water and that mission timeline is of significant importance given the short seven-to-ten-day mission timeline, worse detection with an 8m column may lead to overlooking other substances existing on the moon that could advance planetary science. Thus, I recommend the 20m column. However, if mission timeline and water separation are deemed the highest priority, the 8m column should be selected due to its ability to separate water within a shorter run time than the 20m column.
The effects of age and step length on joint kinematics and kinetics of large out-and-back steps.
Schulz, Brian W; Ashton-Miller, James A; Alexander, Neil B
2008-06-01
Maximum step length (MSL) is a clinical test that has been shown to correlate with age, various measures of fall risk, and knee and hip joint extension speed, strength, and power capacities, but little is known about the kinematics and kinetics of the large out-and-back step utilized. Body motions and ground reaction forces were recorded for 11 unimpaired younger and 10 older women while attaining maximum step length. Joint kinematics and kinetics were calculated using inverse dynamics. The effects of age group and step length on the biomechanics of these large out-and-back steps were determined. Maximum step length was 40% greater in the younger than in the older women (P<0.0001). Peak knee and hip, but not ankle, angle, velocity, moment, and power were generally greater for younger women and longer steps. After controlling for age group, step length generally explained significant additional variance in hip and torso kinematics and kinetics (incremental R2=0.09-0.37). The young reached their peak knee extension moment immediately after landing of the step out, while the old reached their peak knee extension moment just before the return step liftoff (P=0.03). Maximum step length is strongly associated with hip kinematics and kinetics. Delays in peak knee extension moment that appear to be unrelated to step length, may indicate a reduced ability of older women to rapidly apply force to the ground with the stepping leg and thus arrest the momentum of a fall.
The Lumbar Lordosis in Males and Females, Revisited.
Hay, Ori; Dar, Gali; Abbas, Janan; Stein, Dan; May, Hila; Masharawi, Youssef; Peled, Nathan; Hershkovitz, Israel
2015-01-01
Whether differences exist in male and female lumbar lordosis has been debated by researchers who are divided as to the nature of variations in the spinal curve, their origin, reasoning, and implications from a morphological, functional and evolutionary perspective. Evaluation of the spinal curvature is constructive in understanding the evolution of the spine, as well as its pathology, planning of surgical procedures, monitoring its progression and treatment of spinal deformities. The aim of the current study was to revisit the nature of lumbar curve in males and females. Our new automated method uses CT imaging of the spine to measure lumbar curvature in males and females. The curves extracted from 158 individuals were based on the spinal canal, thus avoiding traditional pitfalls of using bone features for curve estimation. The model analysis was carried out on the entire curve, whereby both local and global descriptors were examined in a single framework. Six parameters were calculated: segment length, curve length, curvedness, lordosis peak location, lordosis cranial peak height, and lordosis caudal peak height. Compared to males, the female spine manifested a statistically significant greater curvature, a caudally located lordotic peak, and greater cranial peak height. As caudal peak height is similar for males and females, the illusion of deeper lordosis among females is due partially to the fact that the upper part of the female lumbar curve is positioned more dorsally (more backwardly inclined). Males and females manifest different lumbar curve shape, yet similar amount of inward curving (lordosis). The morphological characteristics of the female spine were probably developed to reduce stress on the vertebral elements during pregnancy and nursing.
Extracting the respiration cycle lengths from ECG signal recorded with bed sheet electrodes
NASA Astrophysics Data System (ADS)
Vehkaoja, A.; Peltokangas, M.; Lekkala, J.
2013-09-01
A method for recognizing the respiration cycle lengths from the electrocardiographic (ECG) signal recorded with textile electrodes that are attached to a bed sheet is proposed. The method uses two features extracted from the ECG that are affected by the respiration: respiratory sinus arrhythmia and the amplitude of the R-peaks. The proposed method was tested in one hour long recordings with ten healthy young adults. A relative mean absolute error of 5.6 % was achieved when the algorithm was able to provide a result for approximately 40 % of the time. 90 % of the values were within 0.5 s and 97 % within 1 s from the reference respiration value. In addition to the instantaneous respiration cycle lengths, also the mean values during 1 and 5 minutes epochs are calculated. The effect of the ECG signal source is evaluated by calculating the result also from the simultaneously recorded reference ECG signal. The acquired respiration information can be used in the estimation of sleep quality and the detection of sleep disorders.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Garimella, Sandilya V. B.; Ibrahim, Yehia M.; Tang, Keqi
A novel concept for ion spatial peak compression is described, and discussed primarily in the context of ion mobility spectrometry (IMS). Using theoretical and numerical methods, the effects of using non-constant (e.g., linearly varying) electric fields on ion distributions (e.g., an ion mobility peak) is evaluated both in the physical and temporal domains. The application of linearly decreasing electric field in conjunction with conventional drift field arrangements is shown to lead to a reduction in IMS physical peak width. When multiple ion packets in a selected mobility window are simultaneously subjected to such fields, there is ion packet compression, i.e.,more » a reduction in peak widths of all species. This peak compression occurs with a modest reduction of resolution, but which can be quickly recovered as ions drift in a constant field after the compression event. Compression also yields a significant increase in peak intensities. In addition, approaches for peak compression in traveling wave IMS are also discussed. Ion mobility peak compression can be particularly useful for mitigating diffusion driven peak spreading over very long path length separations (e.g., in cyclic multi-pass arrangements), and for achieving higher S/N and IMS resolution over a selected mobility range.« less
Hogan, John D; Klein, Joshua A; Wu, Jiandong; Chopra, Pradeep; Boons, Geert-Jan; Carvalho, Luis; Lin, Cheng; Zaia, Joseph
2018-04-03
Glycosaminoglycans (GAGs) covalently linked to proteoglycans (PGs) are characterized by repeating disaccharide units and variable sulfation patterns along the chain. GAG length and sulfation patterns impact disease etiology, cellular signaling, and structural support for cells. We and others have demonstrated the usefulness of tandem mass spectrometry (MS2) for assigning the structures of GAG saccharides; however, manual interpretation of tandem mass spectra is time-consuming, so computational methods must be employed. In the proteomics domain, the identification of monoisotopic peaks and charge states relies on algorithms that use averagine, or the average building block of the compound class being analyzed. While these methods perform well for protein and peptide spectra, they perform poorly on GAG tandem mass spectra, due to the fact that a single average building block does not characterize the variable sulfation of GAG disaccharide units. In addition, it is necessary to assign product ion isotope patterns in order to interpret the tandem mass spectra of GAG saccharides. To address these problems, we developed GAGfinder, the first tandem mass spectrum peak finding algorithm developed specifically for GAGs. We define peak finding as assigning experimental isotopic peaks directly to a given product ion composition, as opposed to deconvolution or peak picking, which are terms more accurately describing the existing methods previously mentioned. GAGfinder is a targeted, brute force approach to spectrum analysis that utilizes precursor composition information to generate all theoretical fragments. GAGfinder also performs peak isotope composition annotation, which is typically a subsequent step for averagine-based methods. Data are available via ProteomeXchange with identifier PXD009101. Published under license by The American Society for Biochemistry and Molecular Biology, Inc.
Donohue, Kevin D.; Unnikrishnan, Harikrishnan; Kryscio, Richard J.
2015-01-01
Purpose This article presents a quantitative method for assessing instantaneous and average lateral vocal-fold motion from high-speed digital imaging, with a focus on developmental changes in vocal-fold kinematics during childhood. Method Vocal-fold vibrations were analyzed for 28 children (aged 5–11 years) and 28 adults (aged 21–45 years) without voice disorders. The following kinematic features were analyzed from the vocal-fold displacement waveforms: relative velocity-based features (normalized average and peak opening and closing velocities), relative acceleration-based features (normalized peak opening and closing accelerations), speed quotient, and normalized peak displacement. Results Children exhibited significantly larger normalized peak displacements, normalized average and peak opening velocities, normalized average and peak closing velocities, peak opening and closing accelerations, and speed quotient compared to adult women. Values of normalized average closing velocity and speed quotient were higher in children compared to adult men. Conclusions When compared to adult men, developing children typically have higher estimates of kinematic features related to normalized displacement and its derivatives. In most cases, the kinematic features of children are closer to those of adult men than adult women. Even though boys experience greater changes in glottal length and pitch as they mature, results indicate that girls experience greater changes in kinematic features compared to boys. PMID:25652615
Kinematics of pediatric crash dummies seated on vehicle seats with realistic belt geometry.
Klinich, Kathleen D; Reed, Matthew P; Ebert, Sheila M; Rupp, Jonathan D
2014-01-01
A series of sled tests was performed using vehicle seats and Hybrid-III 6-year-old (6YO) and 10YO anthropomorphic test devices (ATDs) to explore possibilities for improving occupant protection for children who are not using belt-positioning booster seats. Cushion length was varied from production length of 450 mm to a shorter length of 350 mm. Lap belt geometry was set to rear, mid, and forward anchorage locations that span the range of lap belt angles found in vehicles. Six tests each were performed with the 6YO and 10YO Hybrid III ATDs. One additional test was performed using a booster seat with the 6YO. The ATDs were positioned using an updated version of the University of Michigan Transportation Research Institute (UMTRI) seating procedure that positions the ATD hips further forward with longer seat cushions to reflect the effect of cushion length on posture that has been measured with child volunteers. ATD kinematics were evaluated using peak head excursion, peak knee excursion, the difference between peak head and peak knee excursion, and the maximum torso angle. Shortening the seat cushion improved kinematic outcomes, particularly for the 10YO. Lap belt geometry had a greater effect on kinematics with the longer cushion length, with mid or forward belt geometries producing better kinematics than the rearward belt geometry. The worst kinematics for both ATDs occurred with the long cushion length and rearward lap belt geometry. The improvements in kinematics from shorter cushion length or more forward belt geometry are smaller than those provided by a booster seat. The results show potential benefits in occupant protection from shortening cushion length and increasing lap belt angles, particularly for children the size of the 10YO ATD.
Multiple polarization states of vector soliton in fiber laser
NASA Astrophysics Data System (ADS)
Chen, Weicheng; Xu, Wencheng; Cao, Hui; Han, Dingan
2007-11-01
Vector soliton is obtained in erbium-doped fiber laser via nonlinear polarization rotation techniques. In experiment, we observe the every 4- and 7-pulse sinusoidal peak modulation. Temporal pulse sinusoidal peak modulation owes to evolution behavior of vector solitons in multiple polarization states. The polarizer in the laser modulates the mode-locked pulses with different polarization states into periodical pulse train intensities modulation. Moreover, the increasing pumping power lead to the appearance of the harmonic pulses and change the equivalent beat length to accelerate the polarization rotation. When the laser cavity length is the n-th multiple ratios to the beat length to maintain the mode-locking, the mode-locked vector soliton is in n-th multiple polarization states, exhibiting every n-pulse sinusoidal peak modulation.
Bedoya, Maria A; Delgado, Jorge; Berman, Jeffrey I; Chauvin, Nancy A; Zurakowski, David; Ramirez-Grueso, Raul; Ntoulia, Aikaterini; Jaramillo, Diego
2017-07-01
Purpose To determine the changes of diffusion-tensor imaging (DTI) and tractography in the distal femur and proximal tibia related to age, sex, and height. Materials and Methods Following institutional review board approval, with waiver of consent and with HIPAA compliance, the authors retrospectively analyzed DTI images of the knee in 151 children, 73 girls (median age, 14.1 years; range, 6.5-17.8 years) and 78 boys (median age, 16.6 years; range, 6.9-17.9 years), studied from January 2013 to October 2014. At sagittal echo-planar DTI (20 directions, b values of 0 and 600 sec/mm 2 ), regions of interest were placed in the tibial and femoral physes. Using a fractional anisotropy threshold of 0.15 and an angle threshold of 40°, the authors performed tractography and measured apparent diffusion coefficient (ADC) and tract length and volume. Changes related to age, sex, and height were evaluated by using fitted nonlinear polynomial functions on bootstrapped samples. Results Femoral tract volume and length increased and then decreased with age (P < .001); the peaks of femoral tract volume are consistent with the growth spurt, occurring earlier in girls (10.8 years) than in boys (13.0 years) (P < .001). Girls had smaller tract volumes in comparison to boys (P = .013). ADC peaks 2 years earlier than tract volume (girls at 9.3 years, boys at 11.0 years). Girls with greater than 50th percentile of height had longer tracts and greater tract volumes compared with girls with less than 50th percentile (P < .020). DTI parameters of boys do not correlate with percentile of height (P > .300). Conclusion DTI of the physis and metaphysis shows greater tract length and volumes in subjects who are at ages when the growth is fastest. ADC and tract length and volume have an earlier and smaller peak in girls than in boys. Femoral tract length and volume are larger in taller girls. © RSNA, 2017.
Bowersock, Collin D; Willy, Richard W; DeVita, Paul; Willson, John D
2017-10-01
The purpose of this study was to examine the effects of step length and foot strike pattern along with their interaction on tibiofemoral joint (TFJ) and medial compartment TFJ kinetics during running. Nineteen participants ran with a rear foot strike pattern at their preferred speed using a short (-10%), preferred, and long (+10%) step length. These step length conditions were then repeated using a forefoot strike pattern. Regardless of foot strike pattern, a 10% shorter step length resulted in decreased peak contact force, force impulse per step, force impulse per kilometre, and average loading rate at the TFJ and medial compartment, while a 10% increased step length had the opposite effects (all P < 0.05). A forefoot strike pattern significantly lowered TFJ and medial compartment TFJ average loading rates compared with a rear foot strike pattern (both <0.05) but did not change TFJ or medial compartment peak force, force impulse per step, or force impulse per km. The combination of a shorter step length and forefoot strike pattern produced the greatest reduction in peak medial compartment contact force (P < 0.05). Knowledge of these running modification effects may be relevant to the management or prevention of TFJ injury or pathology among runners.
Stalk-length-dependence of the contractility of Vorticella convallaria
NASA Astrophysics Data System (ADS)
Gul Chung, Eun; Ryu, Sangjin
2017-12-01
Vorticella convallaria is a sessile protozoan of which the spasmoneme contracts on a millisecond timescale. Because this contraction is induced and powered by the binding of calcium ions (Ca2+), the spasmoneme showcases Ca2+-powered cellular motility. Because the isometric tension of V. convallaria increases linearly with its stalk length, it is hypothesized that the contractility of V. convallaria during unhindered contraction depends on the stalk length. In this study, the contractile force and energetics of V. convallaria cells of different stalk lengths were evaluated using a fluid dynamic drag model which accounts for the unsteadiness and finite Reynolds number of the water flow caused by contracting V. convallaria and the wall effect of the no-slip substrate. It was found that the contraction displacement, peak contraction speed, peak contractile force, total mechanical work, and peak power depended on the stalk length. The observed stalk-length-dependencies were simulated using a damped spring model, and the model estimated that the average spring constant of the contracting stalk was 1.34 nN µm-1. These observed length-dependencies of Vorticella’s key contractility parameters reflect the biophysical mechanism of the spasmonemal contraction, and thus they should be considered in developing a theoretical model of the Vorticella spasmoneme.
NASA Astrophysics Data System (ADS)
Zhuo, Yan-Qun; Ma, Jin; Guo, Yan-Shuang; Ji, Yun-Tao
In stick-slip experiments modeling the occurrence of earthquakes, the meta-instability stage (MIS) is the process that occurs between the peak differential stress and the onset of sudden stress drop. The MIS is the final stage before a fault becomes unstable. Thus, identification of the MIS can help to assess the proximity of the fault to the earthquake critical time. A series of stick-slip experiments on a simulated strike-slip fault were conducted using a biaxial servo-controlled press machine. Digital images of the sample surface were obtained via a high speed camera and processed using a digital image correlation method for analysis of the fault displacement field. Two parameters, A and S, are defined based on fault displacement. A, the normalized length of local pre-slip areas identified by the strike-slip component of fault displacement, is the ratio of the total length of the local pre-slip areas to the length of the fault within the observed areas and quantifies the growth of local unstable areas along the fault. S, the normalized entropy of fault displacement directions, is derived from Shannon entropy and quantifies the disorder of fault displacement directions along the fault. Based on the fault displacement field of three stick-slip events under different loading rates, the experimental results show the following: (1) Both A and S can be expressed as power functions of the normalized time during the non-linearity stage and the MIS. The peak curvatures of A and S represent the onsets of the distinct increase of A and the distinct reduction of S, respectively. (2) During each stick-slip event, the fault evolves into the MIS soon after the curvatures of both A and S reach their peak values, which indicates that the MIS is a synergetic process from independent to cooperative behavior among various parts of a fault and can be approximately identified via the peak curvatures of A and S. A possible application of these experimental results to field conditions is provided. However, further validation is required via additional experiments and exercises.
Efficient 1.5-μm Raman generation in ethane-filled hollow-core fiber
NASA Astrophysics Data System (ADS)
Chen, Yubin; Gu, Bo; Wang, Zefeng; Lu, Qisheng
2016-11-01
We demonstrated for the first time a novel and effective method for obtaining both high peak-power and narrow linewidth 1.5 μm fiber sources through gas Raman effect in hollow core fibers. An Ethane-filled ice-cream antiresonance hollow-core fiber is pumped with a high peak-power pulse 1064 nm microchip laser, generating 1552.7 nm Stokes wave by pure vibrational stimulated Raman scattering of ethane molecules. A maximum peak-power of about 400 kW is achieved with 6 meter fiber length at 2 bar pressure, and the linewidth is about 6.3 GHz. The maximum Raman conversion efficiency of 1064 nm to 1552.7 nm is about 38%, and the corresponding laser slope efficiency is about 61.5%.
Multiple laser pulse ignition method and apparatus
Early, James W.
1998-01-01
Two or more laser light pulses with certain differing temporal lengths and peak pulse powers can be employed sequentially to regulate the rate and duration of laser energy delivery to fuel mixtures, thereby improving fuel ignition performance over a wide range of fuel parameters such as fuel/oxidizer ratios, fuel droplet size, number density and velocity within a fuel aerosol, and initial fuel temperatures.
Production of oscillatory flow in wind tunnels
NASA Astrophysics Data System (ADS)
Al-Asmi, K.; Castro, I. P.
1993-06-01
A method for producing oscillatory flow in open-circuit wind tunnels driven by centrifugal fans is described. Performance characteristics of a new device installed on two such tunnels of greatly differing size are presented. It is shown that sinusoidal variations of the working section flow, having peak-to-peak amplitudes up to at least 30 percent of the mean flow speed and frequencies up to, typically, that corresponding to the acoustic quarter-wave-length frequency determined by the tunnel size, can be obtained with negligible harmonic distortion or acoustic noise difficulties. A brief review of the various methods that have been used previously is included, and the advantages and disadvantages of these different techniques are highlighted. The present technique seems to represent a significant improvement over many of them.
Effects of antenna length and material on output power and detection of miniature radio transmitters
Beeman, J.W.; Bower, N.; Juhnke, S.; Dingmon, L.; Van Den, Tillaart; Thomas, T.
2007-01-01
The optimal antenna of transmitters used in small aquatic animals is often a compromise between efficient radio wave propagation and effects on animal behavior. Radio transmission efficiency generally increases with diameter and length of the conductor, but increased antenna length or weight can adversely affect animal behavior. We evaluated the effects of changing antenna length and material on the subsequent tag output power, reception, and detection of tagged fish. In a laboratory, we compared the relative signal strengths in water of 150 MHz transmitters over a range of antenna lengths (from 6 to 30 cm) and materials (one weighing about half of the other). The peak relative signal strengths were at 20 and 22 cm, which are approximately one wavelength underwater at the test frequency. The peak relative signal strengths at these lengths were approximately 50% greater than those of 30 cm antennas, a length commonly used in fisheries research. Few significant differences were present in distances for the operator to hear or the telemetry receiver to decode transmitters from a boat-mounted receiving system based on antenna length, but the percent of tagged fish detected passing a hydroelectric dam fitted with an array of receiving systems was significantly greater at the antenna length with peak output power in laboratory tests. This study indicates careful choice of antenna length and material of small transmitters can be used to reduce weight and possible antenna effects on animal behavior, to maximize tag output power and detection, or to balance these factors based on the needs of the application. ?? 2007 Springer Science+Business Media B.V.
Steiner, M. A.; Bunn, J. R.; Einhorn, J. R.; ...
2017-05-16
This study reports an angular diffraction peak shift that scales linearly with the neutron beam path length traveled through a diffracting sample. This shift was observed in the context of mapping the residual stress state of a large U–8 wt% Mo casting, as well as during complementary measurements on a smaller casting of the same material. If uncorrected, this peak shift implies a non-physical level of residual stress. A hypothesis for the origin of this shift is presented, based upon non-ideal focusing of the neutron monochromator in combination with changes to the wavelength distribution reaching the detector due to factorsmore » such as attenuation. The magnitude of the shift is observed to vary linearly with the width of the diffraction peak reaching the detector. Consideration of this shift will be important for strain measurements requiring long path lengths through samples with significant attenuation. This effect can probably be reduced by selecting smaller voxel slit widths.« less
Conditions and phase shift of fluid resonance in narrow gaps of bottom mounted caissons
NASA Astrophysics Data System (ADS)
Zhu, Da-tong; Wang, Xing-gang; Liu, Qing-jun
2017-12-01
This paper studies the viscid and inviscid fluid resonance in gaps of bottom mounted caissons on the basis of the plane wave hypothesis and full wave model. The theoretical analysis and the numerical results demonstrate that the condition for the appearance of fluid resonance in narrow gaps is kh=(2 n+1)π ( n=0, 1, 2, 3, …), rather than kh= nπ ( n=0, 1, 2, 3, …); the transmission peaks in viscid fluid are related to the resonance peaks in the gaps. k and h stand for the wave number and the gap length. The combination of the plane wave hypothesis or the full wave model with the local viscosity model can accurately determine the heights and the locations of the resonance peaks. The upper bound for the appearance of fluid resonance in gaps is 2 b/ L<1 (2 b, grating constant; L, wave length) and the lower bound is h/ b≤1. The main reason for the phase shift of the resonance peaks is the inductive factors. The number of resonance peaks in the spectrum curve is dependent on the ratio of the gap length to the grating constant. The heights and the positions of the resonance peaks predicted by the present models agree well with the experimental data.
Select injury-related variables are affected by stride length and foot strike style during running.
Boyer, Elizabeth R; Derrick, Timothy R
2015-09-01
Some frontal plane and transverse plane variables have been associated with running injury, but it is not known if they differ with foot strike style or as stride length is shortened. To identify if step width, iliotibial band strain and strain rate, positive and negative free moment, pelvic drop, hip adduction, knee internal rotation, and rearfoot eversion differ between habitual rearfoot and habitual mid-/forefoot strikers when running with both a rearfoot strike (RFS) and a mid-/forefoot strike (FFS) at 3 stride lengths. Controlled laboratory study. A total of 42 healthy runners (21 habitual rearfoot, 21 habitual mid-/forefoot) ran overground at 3.35 m/s with both a RFS and a FFS at their preferred stride lengths and 5% and 10% shorter. Variables did not differ between habitual groups. Step width was 1.5 cm narrower for FFS, widening to 0.8 cm as stride length shortened. Iliotibial band strain and strain rate did not differ between foot strikes but decreased as stride length shortened (0.3% and 1.8%/s, respectively). Pelvic drop was reduced 0.7° for FFS compared with RFS, and both pelvic drop and hip adduction decreased as stride length shortened (0.8° and 1.5°, respectively). Peak knee internal rotation was not affected by foot strike or stride length. Peak rearfoot eversion was not different between foot strikes but decreased 0.6° as stride length shortened. Peak positive free moment (normalized to body weight [BW] and height [h]) was not affected by foot strike or stride length. Peak negative free moment was -0.0038 BW·m/h greater for FFS and decreased -0.0004 BW·m/h as stride length shortened. The small decreases in most variables as stride length shortened were likely associated with the concomitant wider step width. RFS had slightly greater pelvic drop, while FFS had slightly narrower step width and greater negative free moment. Shortening one's stride length may decrease or at least not increase propensity for running injuries based on the variables that we measured. One foot strike style does not appear universally better than the other; rather, different foot strike styles may predispose runners to different types of injuries. © 2015 The Author(s).
Generation of High-Power High-Intensity Short X-Ray Free-Electron-Laser Pulses
Guetg, Marc W.; Lutman, Alberto A.; Ding, Yuantao; ...
2018-01-03
X-ray free-electron lasers combine a high pulse power, short pulse length, narrow bandwidth, and high degree of transverse coherence. Any increase in the photon pulse power, while shortening the pulse length, will further push the frontier on several key x-ray free-electron laser applications including single-molecule imaging and novel nonlinear x-ray methods. This Letter shows experimental results at the Linac Coherent Light Source raising its maximum power to more than 300% of the current limit while reducing the photon pulse length to 10 fs. As a result, this was achieved by minimizing residual transverse-longitudinal centroid beam offsets and beam yaw andmore » by correcting the dispersion when operating over 6 kA peak current with a longitudinally shaped beam.« less
Generation of High-Power High-Intensity Short X-Ray Free-Electron-Laser Pulses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guetg, Marc W.; Lutman, Alberto A.; Ding, Yuantao
X-ray free-electron lasers combine a high pulse power, short pulse length, narrow bandwidth, and high degree of transverse coherence. Any increase in the photon pulse power, while shortening the pulse length, will further push the frontier on several key x-ray free-electron laser applications including single-molecule imaging and novel nonlinear x-ray methods. This Letter shows experimental results at the Linac Coherent Light Source raising its maximum power to more than 300% of the current limit while reducing the photon pulse length to 10 fs. As a result, this was achieved by minimizing residual transverse-longitudinal centroid beam offsets and beam yaw andmore » by correcting the dispersion when operating over 6 kA peak current with a longitudinally shaped beam.« less
Thermal power and heat energy of cloud-to-ground lightning process
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Xuejuan; Yuan, Ping; Xue, Simin
2016-07-15
A cloud-to-ground lightning flash with nine return strokes has been recorded using a high speed slitless spectrograph and a system composed of a fast antenna and a slow antenna. Based on the spectral data and the synchronous electric field changes that were caused by the lightning, the electrical conductivity, the channel radii, the resistance per unit length, the peak current, the thermal power at the instant of peak current, and the heat energy per unit length during the first 5 μs in the discharge channel have all been calculated. The results indicate that the channel radii have linear relationships with themore » peak current. The thermal power at the peak current time increases with increasing resistance, but exponential decays with the square of the peak current.« less
Asemani, Davud; Morsheddost, Hassan; Shalchy, Mahsa Alizadeh
2017-06-01
Functional magnetic resonance imaging (fMRI) can generate brain images that show neuronal activity due to sensory, cognitive or motor tasks. Haemodynamic response function (HRF) may be considered as a biomarker to discriminate the Alzheimer disease (AD) from healthy ageing. As blood-oxygenation-level-dependent fMRI signal is much weak and noisy, particularly for the elderly subjects, a robust method is necessary for HRF estimation to efficiently differentiate the AD. After applying minimum description length wavelet as an extra denoising step, deconvolution algorithm is here employed for HRF estimation, substituting the averaging method used in the previous works. The HRF amplitude peaks are compared for three groups HRF of young, non-demented and demented elderly groups for both vision and motor regions. Prior works often reported significant differences in the HRF peak amplitude between the young and the elderly. The authors' experimentations show that the HRF peaks are not significantly different comparing the young adults with the elderly (either demented or non-demented). It is here demonstrated that the contradictory findings of the previous studies on the HRF peaks for the elderly compared with the young are originated from the noise contribution in fMRI data.
Lactation curves of dairy camels in an intensive system.
Musaad, Abdelgadir; Faye, Bernard; Nikhela, Abdelmoneim Abu
2013-04-01
Weekly milk records of 47 she-camels in a multibreed dairy camel herd were collected for over a period of 5 years. A total of 72 lactation curves were defined, and relationships with parity, calving season, lactation length, milk production level, following lactations, and dam weight were analyzed. Overall mean values were milk yield up to 12 months, 1,970 ± 790 l; lactation length, 12.5 months; persistency, 94.7 %; weekly peak yield, 50.7 l; monthly peak yield, 220 ± 90 l; and the number of weeks to reach peak yield, 28. The highest productivity was recorded in summer with a weekly mean of 48.2 ± 19.4 l, compared with 34.1 ± 16.3 l in winter. The highest average yield recorded was for camels at sixth parity, whereas the highest weekly peak was at eighth parity, and highest persistency at fifth parity. Camels that calved during the cold months (November to February) were most productives, with the highest persistency, peak yield, and longest lactation length. Four types of curves were identified corresponding to different parities and milk yield levels. Based on these data, specific models for camels are proposed.
Multiple laser pulse ignition method and apparatus
Early, J.W.
1998-05-26
Two or more laser light pulses with certain differing temporal lengths and peak pulse powers can be employed sequentially to regulate the rate and duration of laser energy delivery to fuel mixtures, thereby improving fuel ignition performance over a wide range of fuel parameters such as fuel/oxidizer ratios, fuel droplet size, number density and velocity within a fuel aerosol, and initial fuel temperatures. 18 figs.
NASA Astrophysics Data System (ADS)
Li, Jun; Zhang, Song Bin; Ye, Bang Jiao; Wang, Jian Guo; Janev, R. K.
2016-12-01
Low energy electron-impact ionization of hydrogen atom in Debye plasmas has been investigated by employing the exterior complex scaling method. The interactions between the charged particles in the plasma have been represented by Debye-Hückel potentials. Triple differential cross sections (TDCS) in the coplanar equal-energy-sharing geometry at an incident energy of 15.6 eV for different screening lengths are reported. As the screening strength increases, TDCS change significantly. The evolutions of dominant typical peak structures of the TDCS are studied in detail for different screening lengths and for different coplanar equal-energy-sharing geometries.
Shen, Chong; Li, Jie; Zhang, Xiaoming; Shi, Yunbo; Tang, Jun; Cao, Huiliang; Liu, Jun
2016-01-01
The different noise components in a dual-mass micro-electromechanical system (MEMS) gyroscope structure is analyzed in this paper, including mechanical-thermal noise (MTN), electronic-thermal noise (ETN), flicker noise (FN) and Coriolis signal in-phase noise (IPN). The structure equivalent electronic model is established, and an improved white Gaussian noise reduction method for dual-mass MEMS gyroscopes is proposed which is based on sample entropy empirical mode decomposition (SEEMD) and time-frequency peak filtering (TFPF). There is a contradiction in TFPS, i.e., selecting a short window length may lead to good preservation of signal amplitude but bad random noise reduction, whereas selecting a long window length may lead to serious attenuation of the signal amplitude but effective random noise reduction. In order to achieve a good tradeoff between valid signal amplitude preservation and random noise reduction, SEEMD is adopted to improve TFPF. Firstly, the original signal is decomposed into intrinsic mode functions (IMFs) by EMD, and the SE of each IMF is calculated in order to classify the numerous IMFs into three different components; then short window TFPF is employed for low frequency component of IMFs, and long window TFPF is employed for high frequency component of IMFs, and the noise component of IMFs is wiped off directly; at last the final signal is obtained after reconstruction. Rotation experimental and temperature experimental are carried out to verify the proposed SEEMD-TFPF algorithm, the verification and comparison results show that the de-noising performance of SEEMD-TFPF is better than that achievable with the traditional wavelet, Kalman filter and fixed window length TFPF methods. PMID:27258276
Shen, Chong; Li, Jie; Zhang, Xiaoming; Shi, Yunbo; Tang, Jun; Cao, Huiliang; Liu, Jun
2016-05-31
The different noise components in a dual-mass micro-electromechanical system (MEMS) gyroscope structure is analyzed in this paper, including mechanical-thermal noise (MTN), electronic-thermal noise (ETN), flicker noise (FN) and Coriolis signal in-phase noise (IPN). The structure equivalent electronic model is established, and an improved white Gaussian noise reduction method for dual-mass MEMS gyroscopes is proposed which is based on sample entropy empirical mode decomposition (SEEMD) and time-frequency peak filtering (TFPF). There is a contradiction in TFPS, i.e., selecting a short window length may lead to good preservation of signal amplitude but bad random noise reduction, whereas selecting a long window length may lead to serious attenuation of the signal amplitude but effective random noise reduction. In order to achieve a good tradeoff between valid signal amplitude preservation and random noise reduction, SEEMD is adopted to improve TFPF. Firstly, the original signal is decomposed into intrinsic mode functions (IMFs) by EMD, and the SE of each IMF is calculated in order to classify the numerous IMFs into three different components; then short window TFPF is employed for low frequency component of IMFs, and long window TFPF is employed for high frequency component of IMFs, and the noise component of IMFs is wiped off directly; at last the final signal is obtained after reconstruction. Rotation experimental and temperature experimental are carried out to verify the proposed SEEMD-TFPF algorithm, the verification and comparison results show that the de-noising performance of SEEMD-TFPF is better than that achievable with the traditional wavelet, Kalman filter and fixed window length TFPF methods.
In Vivo Measurement of Pediatric Vocal Fold Motion Using Structured Light Laser Projection
Patel, Rita R.; Donohue, Kevin D.; Lau, Daniel; Unnikrishnan, Harikrishnan
2013-01-01
Summary Objective The aim of the study was to present the development of a miniature structured light laser projection endoscope and to quantify vocal fold length and vibratory features related to impact stress of the pediatric glottis using high-speed imaging. Study Design The custom-developed laser projection system consists of a green laser with a 4-mm diameter optics module at the tip of the endoscope, projecting 20 vertical laser lines on the glottis. Measurements of absolute phonatory vocal fold length, membranous vocal fold length, peak amplitude, amplitude-to-length ratio, average closing velocity, and impact velocity were obtained in five children (6–9 years), two adult male and three adult female participants without voice disorders, and one child (10 years) with bilateral vocal fold nodules during modal phonation. Results Independent measurements made on the glottal length of a vocal fold phantom demonstrated a 0.13 mm bias error with a standard deviation of 0.23 mm, indicating adequate precision and accuracy for measuring vocal fold structures and displacement. First, in vivo measurements of amplitude-to-length ratio, peak closing velocity, and impact velocity during phonation in pediatric population and a child with vocal fold nodules are reported. Conclusion The proposed laser projection system can be used to obtain in vivo measurements of absolute length and vibratory features in children and adults. Children have large amplitude-to-length ratio compared with typically developing adults, whereas nodules result in larger peak amplitude, amplitude-to-length ratio, average closing velocity, and impact velocity compared with typically developing children. PMID:23809569
WONG, JACKLYN; ASTETE, HELVIO; MORRISON, AMY C.; SCOTT, THOMAS W.
2011-01-01
When devising methods to sample Aedes aegypti (L.) eggs from naturally-occurring containers to investigate selective oviposition, failure to take into account certain aspects of Ae. aegypti behavior can bias study inferences. In Iquitos, Peru, we tested three assumptions related to designing Ae. aegypti oviposition field studies, as follows: 1) lining containers with paper as an oviposition substrate does not affect oviposition; 2) diurnal egg-laying activity peaks in the late afternoon or early evening, and there is little oviposition during midday; and 3) the gonotrophic cycle length of wild females averages from 3 to 4 d. When wild females were presented with containers lined and unlined with paper toweling, the presence of paper increased oviposition in plastic and metal containers, but had no effect in cement containers. Recording the number of eggs laid by Ae. aegypti every 2 h throughout the day delineated a bimodal diurnal oviposition pattern, with a small morning peak, decreased activity during midday, and a predominant peak in the late afternoon and evening from 16:00 to 20:00 h. Daily monitoring of captive individual F0 females revealed that the gonotrophic cycle length was typically 3– 4 d for the Iquitos population. These findings will be used to adjust field study design to 1) account for sampling eggs using paper toweling, and 2) determine the time of day and number of days over which to sample Ae. aegypti eggs. We explored how failure to consider these behaviors could potentially bias field assessments of oviposition preferences. PMID:21337947
Kinetics of cycle length dependence of ventricular repolarization: effect of autonomic blockade
NASA Technical Reports Server (NTRS)
Raeder, E. A.; Albrecht, P.; Perrott, M.; Cohen, R. J.
1995-01-01
INTRODUCTION: Beat-to-beat adaptation of ventricular repolarization duration to cardiac cycle length and autonomic activity has not been previously characterized in the spontaneously beating human heart. METHODS AND RESULTS: The ECG of 14 healthy subjects was recorded from the supine and upright positions. Autonomic blockade was accomplished by atropine and propranolol. RR and RT intervals were measured by a computer algorithm, and the impulse response (h) from RR to RT computed. In the supine position the maximal adjustment of the RT interval occurred in the first beat following a change in cycle length (hpeak = 17.8 +/- 1.6 msec/sec), but continued to be detectable for 3.8 seconds (2.9-4.7 sec). Propranolol attenuated the peak impulse response to 15.8 +/- 4.0 msec/sec (P = NS). In the standing position the peak impulse response was increased to 25.2 +/- 5.0 msec/sec (P = 0.004 vs supine), and the impulse response duration (hdur) shortened to 1.4 seconds (1.3-1.6). This was reversed by beta blockade (hpeak = 10.7 +/- 3.6 [P = 0.005 vs standing]; hdur = 5.5 sec [4.8-6.1]). Parasympathetic and combined autonomic blockade resulted in too little residual heart rate variability to estimate the impulse response accurately. The slope of the regression of delta RT and delta RR in the supine position was 0.0177 +/- 0.0016, which was closely correlated with the peak impulse response (r = 0.91). CONCLUSIONS: System identification techniques can assist in characterizing the cycle dependence of ventricular repolarization and may provide new insights into conditions associated with abnormal repolarization.
Signal processing methods for in-situ creep specimen monitoring
NASA Astrophysics Data System (ADS)
Guers, Manton J.; Tittmann, Bernhard R.
2018-04-01
Previous work investigated using guided waves for monitoring creep deformation during accelerated life testing. The basic objective was to relate observed changes in the time-of-flight to changes in the environmental temperature and specimen gage length. The work presented in this paper investigated several signal processing strategies for possible application in the in-situ monitoring system. Signal processing methods for both group velocity (wave-packet envelope) and phase velocity (peak tracking) time-of-flight were considered. Although the Analytic Envelope found via the Hilbert transform is commonly applied for group velocity measurements, erratic behavior in the indicated time-of-flight was observed when this technique was applied to the in-situ data. The peak tracking strategies tested had generally linear trends, and tracking local minima in the raw waveform ultimately showed the most consistent results.
rf breakdown tests of mm-wave metallic accelerating structures
Dal Forno, Massimo; Dolgashev, Valery; Bowden, Gordon; ...
2016-01-06
In this study, we explore the physics and frequency-scaling of vacuum rf breakdowns at sub-THz frequencies. We present the experimental results of rf tests performed in metallic mm-wave accelerating structures. These experiments were carried out at the facility for advanced accelerator experimental tests (FACET) at the SLAC National Accelerator Laboratory. The rf fields were excited by the FACET ultrarelativistic electron beam. We compared the performances of metal structures made with copper and stainless steel. The rf frequency of the fundamental accelerating mode, propagating in the structures at the speed of light, varies from 115 to 140 GHz. The traveling wavemore » structures are 0.1 m long and composed of 125 coupled cavities each. We determined the peak electric field and pulse length where the structures were not damaged by rf breakdowns. We calculated the electric and magnetic field correlated with the rf breakdowns using the FACET bunch parameters. The wakefields were calculated by a frequency domain method using periodic eigensolutions. Such a method takes into account wall losses and is applicable to a large variety of geometries. The maximum achieved accelerating gradient is 0.3 GV/m with a peak surface electric field of 1.5 GV/m and a pulse length of about 2.4 ns.« less
Determination of vanillin in vanilla perfumes and air by capillary electrophoresis.
Minematsu, Saaya; Xuan, Guang-Shan; Wu, Xing-Zheng
2013-12-01
The present study investigated capillary electrophoretic detection of vanillin in vanilla perfume and air. An UV-absorbance detector was used in a home-made capillary electrophoretic instrument. A fused silica capillary (outer diameter: 364 μm, inner diameter: 50 μm) was used as a separation capillary, and a high electric voltage (20 kV) was applied across the two ends of the capillary. Total length of the capillary was 70 cm, and the effective length was 55 cm. Experimental results showed that the vanillin peak was detected at about 600, 450, and 500 seconds when pH of running buffers in CE were 7.2, 9.3, and 11.5, respectively. The peak area of vanillin was proportional to its concentration in the range of 0-10(-2) mol/L. The detection limit was about 10(-5) mol/L. Vanillin concentration in a 1% vanilla perfume sample was determined to be about 3×10(-4) mol/L, agreed well with that obtained by a HPLC method. Furthermore, determination of vanillin in air by combination of CE and active carbon adsorption method was investigated. Copyright © 2013 The Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences. Published by Elsevier B.V. All rights reserved.
Turbulence Hazard Metric Based on Peak Accelerations for Jetliner Passengers
NASA Technical Reports Server (NTRS)
Stewart, Eric C.
2005-01-01
Calculations are made of the approximate hazard due to peak normal accelerations of an airplane flying through a simulated vertical wind field associated with a convective frontal system. The calculations are based on a hazard metric developed from a systematic application of a generic math model to 1-cosine discrete gusts of various amplitudes and gust lengths. The math model simulates the three degree-of- freedom longitudinal rigid body motion to vertical gusts and includes (1) fuselage flexibility, (2) the lag in the downwash from the wing to the tail, (3) gradual lift effects, (4) a simplified autopilot, and (5) motion of an unrestrained passenger in the rear cabin. Airplane and passenger response contours are calculated for a matrix of gust amplitudes and gust lengths. The airplane response contours are used to develop an approximate hazard metric of peak normal accelerations as a function of gust amplitude and gust length. The hazard metric is then applied to a two-dimensional simulated vertical wind field of a convective frontal system. The variations of the hazard metric with gust length and airplane heading are demonstrated.
Deterministic methods for multi-control fuel loading optimization
NASA Astrophysics Data System (ADS)
Rahman, Fariz B. Abdul
We have developed a multi-control fuel loading optimization code for pressurized water reactors based on deterministic methods. The objective is to flatten the fuel burnup profile, which maximizes overall energy production. The optimal control problem is formulated using the method of Lagrange multipliers and the direct adjoining approach for treatment of the inequality power peaking constraint. The optimality conditions are derived for a multi-dimensional multi-group optimal control problem via calculus of variations. Due to the Hamiltonian having a linear control, our optimal control problem is solved using the gradient method to minimize the Hamiltonian and a Newton step formulation to obtain the optimal control. We are able to satisfy the power peaking constraint during depletion with the control at beginning of cycle (BOC) by building the proper burnup path forward in time and utilizing the adjoint burnup to propagate the information back to the BOC. Our test results show that we are able to achieve our objective and satisfy the power peaking constraint during depletion using either the fissile enrichment or burnable poison as the control. Our fuel loading designs show an increase of 7.8 equivalent full power days (EFPDs) in cycle length compared with 517.4 EFPDs for the AP600 first cycle.
In Vivo measurement of pediatric vocal fold motion using structured light laser projection.
Patel, Rita R; Donohue, Kevin D; Lau, Daniel; Unnikrishnan, Harikrishnan
2013-07-01
The aim of the study was to present the development of a miniature structured light laser projection endoscope and to quantify vocal fold length and vibratory features related to impact stress of the pediatric glottis using high-speed imaging. The custom-developed laser projection system consists of a green laser with a 4-mm diameter optics module at the tip of the endoscope, projecting 20 vertical laser lines on the glottis. Measurements of absolute phonatory vocal fold length, membranous vocal fold length, peak amplitude, amplitude-to-length ratio, average closing velocity, and impact velocity were obtained in five children (6-9 years), two adult male and three adult female participants without voice disorders, and one child (10 years) with bilateral vocal fold nodules during modal phonation. Independent measurements made on the glottal length of a vocal fold phantom demonstrated a 0.13mm bias error with a standard deviation of 0.23mm, indicating adequate precision and accuracy for measuring vocal fold structures and displacement. First, in vivo measurements of amplitude-to-length ratio, peak closing velocity, and impact velocity during phonation in pediatric population and a child with vocal fold nodules are reported. The proposed laser projection system can be used to obtain in vivo measurements of absolute length and vibratory features in children and adults. Children have large amplitude-to-length ratio compared with typically developing adults, whereas nodules result in larger peak amplitude, amplitude-to-length ratio, average closing velocity, and impact velocity compared with typically developing children. Copyright © 2013 The Voice Foundation. Published by Mosby, Inc. All rights reserved.
Jürimäe, Jaak; Haljaste, Kaja; Cicchella, Antonio; Lätt, Evelin; Purge, Priit; Leppik, Aire; Jürimäe, Toivo
2007-02-01
The purpose of this study was to examine the influence of the energy cost of swimming, body composition, and technical parameters on swimming performance in young swimmers. Twenty-nine swimmers, 15 prepubertal (11.9 +/- 0.3 years; Tanner Stages 1-2) and 14 pubertal (14.3 +/- 1.4 years; Tanner Stages 3-4) boys participated in the study. The energy cost of swimming (Cs) and stroking parameters were assessed over maximal 400-m front-crawl swimming in a 25-m swimming pool. The backward extrapolation technique was used to evaluate peak oxygen consumption (VO2peak). A stroke index (SI; m2 . s(-1) . cycles(-1)) was calculated by multiplying the swimming speed by the stroke length. VO2peak results were compared with VO2peak test in the laboratory (bicycle, 2.86 +/- 0.74 L/min, vs. in water, 2.53 +/- 0.50 L/min; R2 = .713; p = .0001). Stepwise-regression analyses revealed that SI (R2 = .898), in-water VO2peak (R2 = .358), and arm span (R2 = .454) were the best predictors of swimming performance. The backward-extrapolation method could be used to assess VO2peak in young swimmers. SI, arm span, and VO2peak appear to be the major determinants of front-crawl swimming performance in young swimmers.
Patel, Rita; Donohue, Kevin D; Unnikrishnan, Harikrishnan; Kryscio, Richard J
2015-04-01
This article presents a quantitative method for assessing instantaneous and average lateral vocal-fold motion from high-speed digital imaging, with a focus on developmental changes in vocal-fold kinematics during childhood. Vocal-fold vibrations were analyzed for 28 children (aged 5-11 years) and 28 adults (aged 21-45 years) without voice disorders. The following kinematic features were analyzed from the vocal-fold displacement waveforms: relative velocity-based features (normalized average and peak opening and closing velocities), relative acceleration-based features (normalized peak opening and closing accelerations), speed quotient, and normalized peak displacement. Children exhibited significantly larger normalized peak displacements, normalized average and peak opening velocities, normalized average and peak closing velocities, peak opening and closing accelerations, and speed quotient compared to adult women. Values of normalized average closing velocity and speed quotient were higher in children compared to adult men. When compared to adult men, developing children typically have higher estimates of kinematic features related to normalized displacement and its derivatives. In most cases, the kinematic features of children are closer to those of adult men than adult women. Even though boys experience greater changes in glottal length and pitch as they mature, results indicate that girls experience greater changes in kinematic features compared to boys.
NASA Astrophysics Data System (ADS)
Hardacre, Christopher; Holbrey, John D.; Mullan, Claire L.; Youngs, Tristan G. A.; Bowron, Daniel T.
2010-08-01
The presence of local anisotropy in the bulk, isotropic, and ionic liquid phases—leading to local mesoscopic inhomogeneity—with nanoscale segregation and expanding nonpolar domains on increasing the length of the cation alkyl-substituents has been proposed on the basis of molecular dynamics (MD) simulations. However, there has been little conclusive experimental evidence for the existence of intermediate mesoscopic structure between the first/second shell correlations shown by neutron scattering on short chain length based materials and the mesophase structure of the long chain length ionic liquid crystals. Herein, small angle neutron scattering measurements have been performed on selectively H/D-isotopically substituted 1-alkyl-3-methylimidazolium hexafluorophosphate ionic liquids with butyl, hexyl, and octyl substituents. The data show the unambiguous existence of a diffraction peak in the low-Q region for all three liquids which moves to longer distances (lower Q), sharpens, and increases in intensity with increasing length of the alkyl substituent. It is notable, however, that this peak occurs at lower values of Q (longer length scale) than predicted in any of the previously published MD simulations of ionic liquids, and that the magnitude of the scattering from this peak is comparable with that from the remainder of the amorphous ionic liquid. This strongly suggests that the peak arises from the second coordination shells of the ions along the vector of alkyl-chain substituents as a consequence of increasing the anisotropy of the cation, and that there is little or no long-range correlated nanostructure in these ionic liquids.
Adaptation of the length-active tension relationship in rabbit detrusor
Almasri, Atheer M.; Bhatia, Hersch; Klausner, Adam P.; Ratz, Paul H.
2009-01-01
Studies have shown that the length-tension (L-T) relationships in airway and vascular smooth muscles are dynamic and can adapt to length changes over a period of time. Our prior studies have shown that the passive L-T relationship in rabbit detrusor smooth muscle (DSM) is also dynamic and that DSM exhibits adjustable passive stiffness (APS) characterized by a passive L-T curve that can shift along the length axis as a function of strain history and activation history. The present study demonstrates that the active L-T curve for DSM is also dynamic and that the peak active tension produced at a particular muscle length is a function of both strain and activation history. More specifically, this study reveals that the active L-T relationship, or curve, does not have a unique peak tension value with a single ascending and descending limb, but instead reveals that multiple ascending and descending limbs can be exhibited in the same DSM strip. This study also demonstrates that for DSM strips not stretched far enough to reveal a descending limb, the peak active tension produced by a maximal KCl-induced contraction at a short, passively slack muscle length of 3 mm was reduced by 58.6 ± 4.1% (n = 15) following stretches to and contractions at threefold the original muscle length, 9 mm. Moreover, five subsequent contractions at the short muscle length displayed increasingly greater tension; active tension produced by the sixth contraction was 91.5 ± 9.1% of that produced by the prestretch contraction at that length. Together, these findings indicate for the first time that DSM exhibits length adaptation, similar to vascular and airway smooth muscles. In addition, our findings demonstrate that preconditioning, APS and adaptation of the active L-T curve can each impact the maximum total tension observed at a particular DSM length. PMID:19675182
Collimation testing using slit Fresnel diffraction
NASA Astrophysics Data System (ADS)
Luo, Xiaohe; Hui, Mei; Wang, Shanshan; Hou, Yinlong; Zhou, Siyu; Zhu, Qiudong
2018-03-01
A simple collimation testing method based on slit Fresnel diffraction is proposed. The method needs only a CMOS and a slit with no requirement in dimensional accuracy. The light beam to be tested diffracts across the slit and forms a Fresnel diffraction pattern received by CMOS. After analysis, the defocusing amount and the distance between the primary peak point and secondary peak point of diffraction pattern fulfill an expression relationship and then the defocusing amount can be deduced from the expression. The method is applied to both the coherent beam and partially coherent beam, and these two beams are emitted from a laser and light-emitting diode (LED) with a spectrum width of about 50 nm in this paper. Simulations show that the wide spectrum of LED has the effect of smooth filtering to provide higher accuracy. Experiments show that the LED with a spectrum width of about 50 nm has a lower limitation error than the laser and can achieve up to 58.1601 μm with focal length 200 mm and slit width 15 mm.
Li, Junyan; McWilliams, Anthony B; Jin, Zhongmin; Fisher, John; Stone, Martin H; Redmond, Anthony C; Stewart, Todd D
2015-06-01
Symptomatic leg length inequality accounts for 8.7% of total hip replacement related claims made against the UK National Health Service Litigation authority. It has not been established whether symptomatic leg length inequality patients following total hip replacement have abnormal hip kinetics during gait. Hip kinetics in 15 unilateral total hip replacement patients with symptomatic leg length inequality during gait was determined through multibody dynamics and compared to 15 native hip healthy controls and 15 'successful' asymptomatic unilateral total hip replacement patients. More significant differences from normal were found in symptomatic leg length inequality patients than in asymptomatic total hip replacement patients. The leg length inequality patients had altered functions defined by lower gait velocity, reduced stride length, reduced ground reaction force, decreased hip range of motion, reduced hip moment and less dynamic hip force with a 24% lower heel-strike peak, 66% higher mid-stance trough and 37% lower toe-off peak. Greater asymmetry in hip contact force was also observed in leg length inequality patients. These gait adaptions may affect the function of the implant and other healthy joints in symptomatic leg length inequality patients. This study provides important information for the musculoskeletal function and rehabilitation of symptomatic leg length inequality patients. Copyright © 2015. Published by Elsevier Ltd.
Eccentric Torque-Producing Capacity is Influenced by Muscle Length in Older Healthy Adults.
Melo, Ruth C; Takahashi, Anielle C M; Quitério, Robison J; Salvini, Tânia F; Catai, Aparecida M
2016-01-01
Considering the importance of muscle strength to functional capacity in the elderly, the study investigated the effects of age on isokinetic performance and torque production as a function of muscle length. Eleven younger (24.2 ± 2.9 years) and 16 older men (62.7 ± 2.5 years) were subjected to concentric and eccentric isokinetic knee extension/flexion at 60 and 120° · s(-1) through a functional range of motion. The older group presented lower peak torque (in newton-meters) than the young group for both isokinetic contraction types (age effect, p < 0.001). Peak torque deficits in the older group were near 30 and 29% for concentric and eccentric contraction, respectively. Concentric peak torque was lower at 120° · s(-1) than at 60° · s(-1) for both groups (angular velocity effect, p < 0.001). Eccentric knee extension torque was the only exercise tested that showed an interaction effect between age and muscle length (p < 0.001), which suggested different torque responses to the muscle length between groups. Compared with the young group, the eccentric knee extension torque was 22-56% lower in the older group, with the deficits being lower in the shortened muscle length (22-27%) and higher (33-56%) in the stretched muscle length. In older men, the production of eccentric knee strength seems to be dependent on the muscle length. At more stretched positions, older subjects lose the capacity to generate eccentric knee extension torque. More studies are needed to assess the mechanisms involved in eccentric strength preservation with aging and its relationship with muscle length.
Bowersock, Collin D; Willy, Richard W; DeVita, Paul; Willson, John D
2017-03-01
Anterior cruciate ligament reconstruction is associated with early onset knee osteoarthritis. Running is a typical activity following this surgery, but elevated knee joint contact forces are thought to contribute to osteoarthritis degenerative processes. It is therefore clinically relevant to identify interventions to reduce contact forces during running among individuals after anterior cruciate ligament reconstruction. The primary purpose of this study was to evaluate the effect of reducing step length during running on patellofemoral and tibiofemoral joint contact forces among people with a history of anterior cruciate ligament reconstruction. Inter limb knee joint contact force differences during running were also examined. 18 individuals at an average of 54.8months after unilateral anterior cruciate ligament reconstruction ran in 3 step length conditions (preferred, -5%, -10%). Bilateral patellofemoral, tibiofemoral, and medial tibiofemoral compartment peak force, loading rate, impulse, and impulse per kilometer were evaluated between step length conditions and limbs using separate 2 factor analyses of variance. Reducing step length 5% decreased patellofemoral, tibiofemoral, and medial tibiofemoral compartment peak force, impulse, and impulse per kilometer bilaterally. A 10% step length reduction further decreased peak forces and force impulses, but did not further reduce force impulses per kilometer. Tibiofemoral joint impulse, impulse per kilometer, and patellofemoral joint loading rate were lower in the previously injured limb compared to the contralateral limb. Running with a shorter step length is a feasible clinical intervention to reduce knee joint contact forces during running among people with a history of anterior cruciate ligament reconstruction. Copyright © 2017 Elsevier Ltd. All rights reserved.
Inelastic neutron scattering study on boson peaks of imidazolium-based ionic liquids
Kofu, Maiko; Inamura, Yasuhiro; Podlesnyak, Andrey A.; ...
2015-07-26
Low energy excitations of 1-alkyl-3-methylimidazolium ionic liquids (ILs) have been investigated by means of neutron spectroscopy. In the spectra of inelastic scattering, a broad excitation peak referred to as a “boson peak” appeared at 1–3 meV in all of the ILs measured. The intensity of the boson peak was enhanced at the Q positions corresponding to the diffraction peaks, reflecting the in-phase vibrational nature of the boson peak. Furthermore the boson peak energy (E BP) was insensitive to the length of the alkyl-chain but changed depending on the radius of the anion. From the correlation among E BP, the anionmore » radius, and the glass transition temperature T g, we conclude that both E BP and T g in ILs are predominantly governed by the inter-ionic Coulomb interaction which is less influenced by the alkyl-chain length. Furthermore, we also found that the E BP is proportional to the inverse square root of the molecular weight as observed in molecular glasses.« less
Huang, Xue-Feng; Chen, Zhe-Min; Shao, Li-Yang; Cen, Ke-Fa; Sheng, De-Ren; Chen, Jun; Zhou, Hao
2008-02-01
A refractive index sensor based on the thinned and microstructure fiber Bragg grating (ThMs-FBG) was proposed and realized as a chemical sensing. The numerical simulation for the reflectance spectrum of the ThMs-FBG was calculated and the phase shift down-peak could be observed from the reflectance spectrum. Many factors influencing the reflectance spectrum were considered in detail for simulation, including the etched depth, length, and position. The sandwich-solution etching method was utilized to realize the microstructure of the ThMs-FBG, and the photographs of the microstructure were obtained. Experimental results demonstrated that the reflectance spectrum, phase shift down-peak wavelength, and reflected optical intensity of the ThMs-FBG all depended on the surrounding refractive index. However, only the down-peak wavelength of the ThMs-FBG changed with the surrounding temperature. Under the condition that the length and cladding diameter of the ThMs-FBG microstructure were 800 and 14 mum, respectively, and the position of the microstructure of the ThMs-FBG is in the middle of grating region, the refractive index sensitivity of the ThMs-FBG was 0.79 nm/refractive index unit with the wide range of 1.33-1.457 and a high resolution of 1.2 x 10(-3). The temperature sensitivity was 0.0103 nm/ degrees C, which was approximately equal to that of common FBG.
A broadband high-efficiency Doherty power amplifier using symmetrical devices
NASA Astrophysics Data System (ADS)
Cheng, Zhiqun; Zhang, Ming; Li, Jiangzhou; Liu, Guohua
2018-04-01
This paper proposes a method for broadband and high-efficiency amplification of Doherty power amplifier (DPA) using symmetric devices. In order to achieve the perfect load modulation, the carrier amplifier output circuit total power length is designed to odd multiple of 90°, and the peak amplifier output total power length is designed to even multiple of 180°. The proposed method is demonstrated by designing a broadband high-efficiency DPA using identical 10-W packaged GaN HEMT devices. Measurement results show that over 51% drain efficiency is achieved at 6-dB back-off power, over the frequency band of 1.9–2.4 GHz. Project supported by the National Natural Science Foundation of China (No. 60123456), the Zhejiang Provincial Natural Science Foundation of China (No. LZ16F010001), and the Zhejiang Provincial Public Technology Research Project (No. 2016C31070).
Recording 13C-15N HMQC 2D sparse spectra in solids in 30 s
NASA Astrophysics Data System (ADS)
Kupče, Ēriks; Trébosc, Julien; Perrone, Barbara; Lafon, Olivier; Amoureux, Jean-Paul
2018-03-01
We propose a dipolar HMQC Hadamard-encoded (D-HMQC-Hn) experiment for fast 2D correlations of abundant nuclei in solids. The main limitation of the Hadamard methods resides in the length of the encoding pulses, which results from a compromise between the selectivity and the sensitivity due to losses. For this reason, these methods should mainly be used with sparse spectra, and they profit from the increased separation of the resonances at high magnetic fields. In the case of the D-HMQC-Hn experiments, we give a simple rule that allows directly setting the optimum length of the selective pulses, versus the minimum separation of the resonances in the indirect dimension. The demonstration has been performed on a fully 13C,15N labelled f-MLF sample, and it allowed recording the build-up curves of the 13C-15N cross-peaks within 10 min. However, the method could also be used in the case of less sensitive samples, but with more accumulations.
NASA Astrophysics Data System (ADS)
Yan, Yunxiang; Wang, Gang; Sun, Weimin; Luo, A.-Li; Ma, Zhenyu; Li, Jian; Wang, Shuqing
2017-04-01
Focal ratio degradation (FRD) is a major contributor to throughput and light loss in a fibre spectroscopic telescope system. We combine the guided mode theory in geometric optics and a well-known model, the power distribution model (PDM), to predict and explain the FRD dependence properties. We present a robust method by modifying the energy distribution method with f-intercept to control the input condition. This method provides a way to determine the proper position of the fibre end on the focal plane to improve energy utilization and FRD performance, which lifts the relative throughput up to 95 per cent with variation of output focal ratio less than 2 per cent. This method can also help to optimize the arrangement of the position of focal-plane plate to enhance the coupling efficiency in a telescope. To investigate length properties, we modified the PDM by introducing a new parameter, the focal distance f, into the original model to make it available for a multiposition measurement system. The results show that the modified model is robust and feasible for measuring the key parameter d0 to simulate the transmission characteristics. The output focal ratio in the experiment does not follow the prediction trend but shows an interesting phenomenon: the output focal ratio increases first to the peak, then decreases and remains stable finally with increasing fibre length longer than 15 m. This provides a reference for choosing the appropriate length of fibre to improve the FRD performance for the design of the fibre system in a telescope.
Does Foot Anthropometry Predict Metabolic Cost During Running?
van Werkhoven, Herman; Piazza, Stephen J
2017-10-01
Several recent investigations have linked running economy to heel length, with shorter heels being associated with less metabolic energy consumption. It has been hypothesized that shorter heels require larger plantar flexor muscle forces, thus increasing tendon energy storage and reducing metabolic cost. The goal of this study was to investigate this possible mechanism for metabolic cost reduction. Fifteen male subjects ran at 16 km⋅h -1 on a treadmill and subsequently on a force-plate instrumented runway. Measurements of oxygen consumption, kinematics, and ground reaction forces were collected. Correlational analyses were performed between oxygen consumption and anthropometric and kinetic variables associated with the ankle and foot. Correlations were also computed between kinetic variables (peak joint moment and peak tendon force) and heel length. Estimated peak Achilles tendon force normalized to body weight was found to be strongly correlated with heel length normalized to body height (r = -.751, p = .003). Neither heel length nor any other measured or calculated variable were correlated with oxygen consumption, however. Subjects with shorter heels experienced larger Achilles tendon forces, but these forces were not associated with reduced metabolic cost. No other anthropometric and kinetic variables considered explained the variance in metabolic cost across individuals.
Terada, Tomomasa; Mori, Kazuhiro; Inoue, Miki; Yasunobu, Hayabuchi
2016-11-01
Assessment of longitudinal left ventricular (LV) function is important for early detection of cardiac dysfunction. Although mitral annular plane systolic excursion (MAPSE) obtained by M-mode echocardiography offers a simple method for assessing longitudinal LV function, normal values of MAPSE for children change according to body size. To minimize the effects of body size, MAPSE was divided by LV long-axis length (MAPSE/L). MAPSE/L was measured in 210 healthy children from birth to 15 years of age and classified into five subgroups. MAPSE/L was then compared with 10 parameters in 136 children (age, heart rate, mean blood pressure, ejection fraction of the LV (EF), peak atrial flow velocity/peak early diastolic flow velocity of mitral flow, tissue Doppler velocity during systole (s') and early diastole (e'), E/e' ratio, Tei index, and global longitudinal strain (GLS) of the LV by the speckle tracking method). MAPSE/L was significantly lower in the neonate group than in the remaining four groups. MAPSE/L then increased with age to peak at 1-5 years and gradually decreased thereafter. In all cases beyond the neonatal period, MAPSE/L was more than 0.17. Among various parameters, GLS, age, EF, Tei index and s' were significantly associated with MAPSE/L in that order. In univariate analysis, GLS was most significantly associated with MAPSE/L (r=.56). We have established normal reference values for MPSE/L in healthy children. MAPSE/L is expected to offer a simple parameter to evaluate LV longitudinal systolic function during daily routine echocardiography in children. © 2016, Wiley Periodicals, Inc.
Mulloy, Barbara; Hogwood, John
2015-01-01
Glycosaminoglycan samples are usually polydisperse, consisting of molecules with differing length and differing sequence. Methods for measuring the molecular weight of heparin have been developed to assure the quality and consistency of heparin products for medicinal use, and these methods can be applied in other laboratory contexts. In the method described here, high-performance gel permeation chromatography is calibrated using appropriate heparin molecular weight markers or a single broad standard calibrant, and used to characterize the molecular weight distribution of polydisperse samples or the peak molecular weight of monodisperse, or approximately monodisperse, heparin fractions. The same technology can be adapted for use with other glycosaminoglycans.
Transport of light, trace impurities in Alcator C-Mod
NASA Astrophysics Data System (ADS)
Rowan, W. L.; Bespamyatnov, I. O.; Liao, K. T.; Horton, W.; Fu, X. R.; Hughes, J. W.
2012-10-01
Light impurity profiles for boron were measured in ITB, H-mode, L-mode, and I-mode discharges in Alcator C-Mod. Within this wide range of modes, the profiles varied from peaked to hollow to flat. Specifically, hollow profiles are often observed in H-mode, while ITBs produce strong peaking, and L-mode produces moderate peaking. I-mode discharges are characterized by flat impurity profiles. For the study reported here, the profiles were measured with charge exchange recombination spectroscopy. The dependences of Rv/D were sought on dimensionless quantities including ion density scale length, effective charge, collisionality, and temperature scale length. We find that neoclassical transport consistently underestimates the measured transport. The excess measured transport is assumed to be turbulent. The strongest dependence of Rv/D is with temperature scale length. In addition, the measured transport was compared with the prediction of an analytical theory of drift wave turbulence that identifies transport implications for drift waves driven by ion and impurity density gradients.
Origins of DNA Replication and Amplification in the Breast Cancer Genome
2013-09-01
three peaks from the uncorrected data set remain in the corrected set. As shown in Figure 6, the peak on the left disappears as it was caused by Lexo...distribution (p. 14) Shuffled Inter‐peak distance distribution (p. 15) Peak length distribution (p. 16) Number of features per chromosome (p. 17) Correlation...with G4 ( Chromosomes 1, 3, 6, 7, 11, 19 and genome‐wide)(pp. 18-24 Proximity distribution of peaks near Delino ORC sites (p. 25) GC content of
Mukozhiwa, S Y; Khamanga, S M M; Walker, R B
2017-09-01
A capillary zone electrophoresis (CZE) method for the quantitation of captopril (CPT) using UV detection was developed. Influence of electrolyte concentration and system variables on electrophoretic separation was evaluated and a central composite design (CCD) was used to optimize the method. Variables investigated were pH, molarity, applied voltage and capillary length. The influence of sodium metabisulphite on the stability of test solutions was also investigated. The use of sodium metabisulphite prevented degradation of CPT over 24 hours. A fused uncoated silica capillary of 67.5cm total and 57.5 cm effective length was used for analysis. The applied voltage and capillary length affected the migration time of CPT significantly. A 20 mM phosphate buffer adjusted to pH 7.0 was used as running buffer and an applied voltage of 23.90 kV was suitable to effect a separation. The optimized electrophoretic conditions produced sharp, well-resolved peaks for CPT and sodium metabisulphite. Linear regression analysis of the response for CPT standards revealed the method was linear (R2 = 0.9995) over the range 5-70 μg/mL. The limits of quantitation and detection were 5 and 1.5 μg/mL. A simple, rapid and reliable CZE method has been developed and successfully applied to the analysis of commercially available CPT products.
Curved PVDF airborne transducer.
Wang, H; Toda, M
1999-01-01
In the application of airborne ultrasonic ranging measurement, a partially cylindrical (curved) PVDF transducer can effectively couple ultrasound into the air and generate strong sound pressure. Because of its geometrical features, the ultrasound beam angles of a curved PVDF transducer can be unsymmetrical (i.e., broad horizontally and narrow vertically). This feature is desired in some applications. In this work, a curved PVDF air transducer is investigated both theoretically and experimentally. Two resonances were observed in this transducer. They are length extensional mode and flexural bending mode. Surface vibration profiles of these two modes were measured by a laser vibrometer. It was found from the experiment that the surface vibration was not uniform along the curvature direction for both vibration modes. Theoretical calculations based on a model developed in this work confirmed the experimental results. Two displacement peaks were found in the piezoelectric active direction of PVDF film for the length extensional mode; three peaks were found for the flexural bending mode. The observed peak positions were in good agreement with the calculation results. Transient surface displacement measurements revealed that vibration peaks were in phase for the length extensional mode and out of phase for the flexural bending mode. Therefore, the length extensional mode can generate a stronger ultrasound wave than the flexural bending mode. The resonance frequencies and vibration amplitudes of the two modes strongly depend on the structure parameters as well as the material properties. For the transducer design, the theoretical model developed in this work can be used to optimize the ultrasound performance.
NASA Astrophysics Data System (ADS)
Sang, Lixia; Zhao, Yangbo; Niu, Youchen; Bai, Guangmei
2018-02-01
TiO2 with Nanoring/Nanotube (R/T) hierarchical structure can be prepared by tuning the oxidation time and oxidation voltage in the second step anodization. The resulting multiabsorption oscillating peaks in the visible light region present a strong dependence on the tube length which are derived from the interference of light reflected from the top nanorings and the bottom Ti substrate, and the optical path length in TiO2 R/T hierarchical structure can be estimated as about 2 μm. The tube length of the as-prepared TiO2 photoelectrode affects greatly its saturation photocurrent density, and the different tube-wall thickness can change the photocurrent-saturation potential. Under simulated AM 1.5 irradiation (100 mW/cm2), TiO2 R/T hierarchical structure with tube diameters of 20-40 nm and tube length of about 1.5 μm shows higher photocurrent density and hydrogen production rate at the bias of 0 V (vs. Ag/AgCl). The results from the IPCE plots and I-t curves verify that TiO2 R/T hierarchical structure can exhibit the visible light activity, which is more related to the absorption induced by the defects rather than oscillating peaks. Based on the unique multiple light reflection in TiO2 R/T hierarchical structure, surface treatment will pave a way for the better utilization of oscillating peaks in the visible light region.
Thermal effect of diode-pumped solid state lasers based on composite crystals
NASA Astrophysics Data System (ADS)
Hao, Ming-ming; Lu, Guo-guang; Zhu, Hong-bo; Huang, Yun; En, Yun-fei
2013-12-01
Thermal effect of diode-pumped solid-state lasers (DPSSL) based on YAP/Tm:YAP composite crystal is studied by using of finite element method (FEM). It is found that the peak temperature in a composite rod decreases to less than 80% of that in a non-composite crystal. Thermal stress of composite rod is obviously reduced to less than 70% comparing with non-composite crystal. It is also demonstrated that length of thermal lens unchanged with increasing of un-doped crystal length, which means that beam quality of composite laser wouldn't be improved by non-composite crystal. Therefore, it is concluded that using composite crystal would benefit for the properties of temperature and heat stress while insignificance for beam quality of DPSSL.
Yuan, Shen-fang; Jin, Xin; Qiu, Lei; Huang, Hong-mei
2015-03-01
In order to improve the security of aircraft repaired structures, a method of crack propagation monitoring in repaired structures is put forward basing on characteristics of Fiber Bragg Grating (FBG) reflecting spectra in this article. With the cyclic loading effecting on repaired structure, cracks propagate, while non-uniform strain field appears nearby the tip of crack which leads to the FBG sensors' reflecting spectra deformations. The crack propagating can be monitored by extracting the characteristics of FBG sensors' reflecting spectral deformations. A finite element model (FEM) of the specimen is established. Meanwhile, the distributions of strains which are under the action of cracks of different angles and lengths are obtained. The characteristics, such as main peak wavelength shift, area of reflecting spectra, second and third peak value and so on, are extracted from the FBGs' reflecting spectral which are calculated by transfer matrix algorithm. An artificial neural network is built to act as the model between the characteristics of the reflecting spectral and the propagation of crack. As a result, the crack propagation of repaired structures is monitored accurately and the error of crack length is less than 0.5 mm, the error of crack angle is less than 5 degree. The accurately monitoring problem of crack propagation of repaired structures is solved by taking use of this method. It has important significance in aircrafts safety improvement and maintenance cost reducing.
A study of polaritonic transparency in couplers made from excitonic materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Singh, Mahi R.; Racknor, Chris
2015-03-14
We have studied light matter interaction in quantum dot and exciton-polaritonic coupler hybrid systems. The coupler is made by embedding two slabs of an excitonic material (CdS) into a host excitonic material (ZnO). An ensemble of non-interacting quantum dots is doped in the coupler. The bound exciton polariton states are calculated in the coupler using the transfer matrix method in the presence of the coupling between the external light (photons) and excitons. These bound exciton-polaritons interact with the excitons present in the quantum dots and the coupler is acting as a reservoir. The Schrödinger equation method has been used tomore » calculate the absorption coefficient in quantum dots. It is found that when the distance between two slabs (CdS) is greater than decay length of evanescent waves the absorption spectrum has two peaks and one minimum. The minimum corresponds to a transparent state in the system. However, when the distance between the slabs is smaller than the decay length of evanescent waves, the absorption spectra has three peaks and two transparent states. In other words, one transparent state can be switched to two transparent states when the distance between the two layers is modified. This could be achieved by applying stress and strain fields. It is also found that transparent states can be switched on and off by applying an external control laser field.« less
Carmichael, Marc G; Liu, Dikai
2015-01-01
Sensitivity of upper limb strength calculated from a musculoskeletal model was analyzed, with focus on how the sensitivity is affected when the model is adapted to represent a person with physical impairment. Sensitivity was calculated with respect to four muscle-tendon parameters: muscle peak isometric force, muscle optimal length, muscle pennation, and tendon slack length. Results obtained from a musculoskeletal model of average strength showed highest sensitivity to tendon slack length, followed by muscle optimal length and peak isometric force, which is consistent with existing studies. Muscle pennation angle was relatively insensitive. The analysis was repeated after adapting the musculoskeletal model to represent persons with varying severities of physical impairment. Results showed that utilizing the weakened model significantly increased the sensitivity of the calculated strength at the hand, with parameters previously insensitive becoming highly sensitive. This increased sensitivity presents a significant challenge in applications utilizing musculoskeletal models to represent impaired individuals.
The all-fiber cladding-pumped Yb-doped gain-switched laser.
Larsen, C; Hansen, K P; Mattsson, K E; Bang, O
2014-01-27
Gain-switching is an alternative pulsing technique of fiber lasers, which is power scalable and has a low complexity. From a linear stability analysis of rate equations the relaxation oscillation period is derived and from it, the pulse duration is defined. Good agreement between the measured pulse duration and the theoretical prediction is found over a wide range of parameters. In particular we investigate the influence of an often present length of passive fiber in the cavity and show that it introduces a finite minimum in the achievable pulse duration. This minimum pulse duration is shown to occur at longer active fibers length with increased passive length of fiber in the cavity. The peak power is observed to depend linearly on the absorbed pump power and be independent of the passive fiber length. Given these conclusions, the pulse energy, duration, and peak power can be estimated with good precision.
Kumar, Ashish; Kumar, Manjeet; Komaragiri, Rama
2018-04-19
Bradycardia can be modulated using the cardiac pacemaker, an implantable medical device which sets and balances the patient's cardiac health. The device has been widely used to detect and monitor the patient's heart rate. The data collected hence has the highest authenticity assurance and is convenient for further electric stimulation. In the pacemaker, ECG detector is one of the most important element. The device is available in its new digital form, which is more efficient and accurate in performance with the added advantage of economical power consumption platform. In this work, a joint algorithm based on biorthogonal wavelet transform and run-length encoding (RLE) is proposed for QRS complex detection of the ECG signal and compressing the detected ECG data. Biorthogonal wavelet transform of the input ECG signal is first calculated using a modified demand based filter bank architecture which consists of a series combination of three lowpass filters with a highpass filter. Lowpass and highpass filters are realized using a linear phase structure which reduces the hardware cost of the proposed design approximately by 50%. Then, the location of the R-peak is found by comparing the denoised ECG signal with the threshold value. The proposed R-peak detector achieves the highest sensitivity and positive predictivity of 99.75 and 99.98 respectively with the MIT-BIH arrhythmia database. Also, the proposed R-peak detector achieves a comparatively low data error rate (DER) of 0.002. The use of RLE for the compression of detected ECG data achieves a higher compression ratio (CR) of 17.1. To justify the effectiveness of the proposed algorithm, the results have been compared with the existing methods, like Huffman coding/simple predictor, Huffman coding/adaptive, and slope predictor/fixed length packaging.
Patellofemoral joint stress during running with alterations in foot strike pattern.
Vannatta, Charles Nathan; Kernozek, Thomas W
2015-05-01
This study aimed to quantify differences in patellofemoral joint stress that may occur when healthy runners alter their foot strike pattern from their habitual rearfoot strike to a forefoot strike to gain insight on the potential etiology and treatment methods of patellofemoral pain. Sixteen healthy female runners completed 20 running trials in a controlled laboratory setting under rearfoot strike and forefoot strike conditions. Kinetic and kinematic data were used to drive a static optimization technique to estimate individual muscle forces to input into a model of the patellofemoral joint to estimate joint stress during running. Peak patellofemoral joint stress and the stress-time integral over stance phase decreased by 27% and 12%, respectively, in the forefoot strike condition (P < 0.001). Peak vertical ground reaction force increased slightly in the forefoot strike condition (P < 0.001). Peak quadriceps force and average hamstring force decreased, whereas gastrocnemius and soleus muscle forces increased when running with a forefoot strike (P < 0.05). Knee flexion angle at initial contact increased (P < 0.001), total knee excursion decreased (P < 0.001), and no change occurred in peak knee flexion angle (P = 0.238). Step length did not change between conditions (P = 0.375), but the leading leg landed with the foot positioned with a horizontal distance closer to the hip at initial contact in the forefoot strike condition (P < 0.001). Altering one's strike pattern to a forefoot strike results in consistent reductions in patellofemoral joint stress independent of changes in step length. Thus, implementation of forefoot strike training programs may be warranted in the treatment of runners with patellofemoral pain. However, it is suggested that the transition to a forefoot strike pattern should be completed in a graduated manner.
Active multiple plasmon-induced transparencies with detuned asymmetric multi-rectangle resonators
NASA Astrophysics Data System (ADS)
Liu, Dongdong; Wang, Jicheng; Lu, Jian
2016-11-01
The phenomenon of plasmon-induced transparency (PIT) is realized in surface plasmon polariton waveguide at the visible and near-infrared ranges. By adding one and two resonant cavities, the PIT peak(s) was (were) achieved due to destructive interference between the side-coupled rectangle cavity and the bus waveguide. The proposed structures were demonstrated by the finite element method. The simulation results showed that for three rectangle resonators system, not only can we manipulate each single PIT window, but also the double PIT windows simultaneously by adjusting one of the geometrical parameters of the system; for four rectangle resonators system, by changing the widths, the lengths and the refractive index of three cavities simultaneously, we would realize treble PIT peaks and induce an off-to-on PIT optical response. Our novel plasmonic structures and the findings pave the way for new design and engineering of highly integrated optical circuit such as nanoscale optical switching, nanosensor and wavelength-selecting nanostructure.
NASA Astrophysics Data System (ADS)
Wang, Lili; Xin, Xiangjun; Song, Jun; Wang, Honggang; Sai, Yaozhang
2018-02-01
Fiber Bragg sensor is applied for detecting and monitoring the cracks that occur in the reinforced concrete. We use the three-dimensional finite element model to provide the three-axial stresses along the fiber Bragg sensor and then converted the stresses as a wavelength deformation of fiber Bragg grating (FBG) reflected spectrum. For the crack detection, an FBG sensor with 10-mm length is embedded in the reinforced concrete, and its reflection spectrum is measured after loading is applied to the concrete slab. As a result, the main peak wavelength and the ratio of the peak reflectivity to the maximal side-mode reflectivity of the optic-fiber grating represent the fracture severity. The fact that the sharp decreasing of the ratio of the peak reflectivity to the maximal side-mode reflectivity represents the early crack is confirmed by the theoretical calculation. The method can be used to detect the cracks in the reinforced concrete and give safety evaluation of large-scale infrastructure.
NASA Astrophysics Data System (ADS)
Behzad, Somayeh
2017-06-01
The full potential linearized augmented plane wave (FP-LAPW) method within the framework of density functional theory has been used to study effects of strain and thickness on the electronic and optical properties of two-dimensional GaN. The band gap of monolayer and bilayer GaN under compressive in-plane strain change from indirect to direct with bond length shortening. Also, the semiconductor to semimetal transition occurs for monolayer and bilayer GaN under in-plane tensile strain with bond length elongation. It is found that the tensile and compressive strains cause the red and blue shifts in the optical spectra, respectively, for both monolayer and bilayer GaN. Applying the perpendicular strain on the bilayer GaN by decreasing the inter layer distance leads to the shift of valence band maximum towards the Γ point in the band structure and shift of peak positions and variation of peak intensities in ε2(ω) spectrum. The results show that the n-layer GaN has an indirect band gap for n < 16. The results suggest that monolayer and multilayer GaN are good candidates for application in optoelectronics and flexible electronics.
NASA Technical Reports Server (NTRS)
Seldner, K.
1977-01-01
An algorithm was developed to optimally control the traffic signals at each intersection using a discrete time traffic model applicable to heavy or peak traffic. Off line optimization procedures were applied to compute the cycle splits required to minimize the lengths of the vehicle queues and delay at each intersection. The method was applied to an extensive traffic network in Toledo, Ohio. Results obtained with the derived optimal settings are compared with the control settings presently in use.
Ravi, Koustuban; Schimpf, Damian N; Kärtner, Franz X
2016-10-31
The use of laser pulse sequences to drive the cascaded difference frequency generation of high energy, high peak-power and multi-cycle terahertz pulses in cryogenically cooled (100 K) periodically poled Lithium Niobate is proposed and studied. Detailed simulations considering the coupled nonlinear interaction of terahertz and optical waves (or pump depletion), show that unprecedented optical-to-terahertz energy conversion efficiencies > 5%, peak electric fields of hundred(s) of mega volts/meter at terahertz pulse durations of hundred(s) of picoseconds can be achieved. The proposed methods are shown to circumvent laser induced damage limitations at Joule-level pumping by 1µm lasers to enable multi-cycle terahertz sources with pulse energies > 10 milli-joules. Various pulse sequence formats are proposed and analyzed. Numerical calculations for periodically poled structures accounting for cascaded difference frequency generation, self-phase-modulation, cascaded second harmonic generation and laser induced damage are introduced. The physics governing terahertz generation using pulse sequences in this high conversion efficiency regime, limitations and practical considerations are discussed. It is shown that varying the poling period along the crystal length and further reduction of absorption can lead to even higher energy conversion efficiencies >10%. In addition to numerical calculations, an analytic formulation valid for arbitrary pulse formats and closed-form expressions for important cases are presented. Parameters optimizing conversion efficiency in the 0.1-1 THz range, the corresponding peak electric fields, crystal lengths and terahertz pulse properties are furnished.
Yao, Qiu-Mei; Zhou, Jiao; Gale, Robert Peter; Li, Jin-Lan; Li, Ling-Di; Li, Ning; Chen, Shan-Shan; Ruan, Guo-Rui
2015-10-01
Calreticulin (CALR) mutations were recently identified in a substantial proportion of persons with essential thrombocythemia (ET) and with primary myelofibrosis (PMF) without JAK2(V617F). Consequently rapid, sensitive, and specific methods to detect and quantify these mutations are needed. We studied samples from 1088 persons with myeloproliferative neoplasms (MPNs) including 421 JAK2(V617F) negative subjects with ET, PMF, polycythemia vera (PV), chronic myeloid leukemia (CML) and hyper-eosinophilic syndrome (HES). Detection of CALR exon 9 mutations was done by PCR amplification followed by fragment length analysis and direct sequencing. Dilution assays were used to determine CALR mutant allele burden. We detected CALR mutations in blood and bone marrow samples from 152 subjects with ET and with PMF but not in samples from normal or persons with PV, CML, or HES. CALR mutant peaks were distinct from wild-type peaks and dilution experiments indicated a sensitivity level of 0.5-5% for a CALR mutant allele in a wild-type background. Diverse types of mutations were detected including deletions, insertions, and complex indels. All mutations were confirmed by direct sequencing. We also used dilution experiments to quantify mutant allele burden. We were able to reproducibly detect mutant allele levels as low 5% (0.5-5%) in a wild-type background. PCR amplification followed by fragment length analysis is a rapid, sensitive, and specific method for screening persons with MPNs for CALR mutations, especially those with ET and PMF and for estimating mutant allele burden.
X-ray absorption spectral studies of copper (II) mixed ligand complexes
NASA Astrophysics Data System (ADS)
Soni, B.; Dar, Davood Ah; Shrivastava, B. D.; Prasad, J.; Srivastava, K.
2014-09-01
X-ray absorption spectra at the K-edge of copper have been studied in two copper mixed ligand complexes, one having tetramethyethylenediamine (tmen) and the other having tetraethyethylenediamine (teen) as one of the ligands. The spectra have been recorded at BL-8 dispersive extended X-ray absorption fine structure (EXAFS) beamline at the 2.5 GeV INDUS- 2 synchrotron, RRCAT, Indore, India. The data obtained has been processed using the data analysis program Athena. The energy of the K-absorption edge, chemical shift, edge-width and shift of the principal absorption maximum in the complexes have been determined and discussed. The values of these parameters have been found to be approximately the same in both the complexes indicating that the two complexes possess similar chemical environment around the copper metal atom. The chemical shift has been utilized to estimate effective nuclear charge on the absorbing atom. The normalized EXAFS spectra have been Fourier transformed. The position of the first peak in the Fourier transform gives the value of first shell bond length, which is shorter than the actual bond length because of energy dependence of the phase factors in the sine function of the EXAFS equation. This distance is thus the phase- uncorrected bond length. Bond length has also been determined by Levy's, Lytle's and Lytle, Sayers and Stern's (LSS) methods. The results obtained from LSS and the Fourier transformation methods are comparable with each other, since both are phase uncorrected bond lengths.
Isometric contractions of motor units in a fast twitch muscle of the cat
Bagust, J.; Knott, Sarah; Lewis, D. M.; Luck, J. C.; Westerman, R. A.
1973-01-01
1. Isosmetric contractions of cat flexor digitorum longus whole muscles and of functionally isolated motor units have been measured under conditions similar to those used by Buller & Lewis (1965a). 2. Motor unit twitch time to peak was inversely related to axonal conduction velocity. The logarithm of tetanic tension was directly related to conduction velocity. These relationships suggest that each motoneurone has an influence on the muscle fibres which it innervates. 3. The ratio of twitch to tetanic tension was directly related to the time to peak of the motor unit. This fact might be explained by variation between motor units of the duration of `active state'. 4. The muscle length at which tension was maximal varied between motor units and the optima were found over the range of muscle lengths which could occur in the body. Slow motor units had longer optimal lengths. 5. The sample of motor units was considered to be unbiased because the distribution of axon conduction velocities was compatible with reported motor fibre diameter spectra of the muscle nerve. The mean motor unit tetanic tension gave a reasonable estimate of the number of α-motor axons in the muscle nerve. Twitch tensions gave a value that was 40% higher. 6. Motor unit and whole muscle data were in good agreement for length-tetanus tension curves, for times to peak and for twitch-tetanus ratios at long muscle lengths. PMID:4715372
The series-elastic shock absorber: tendons attenuate muscle power during eccentric actions.
Roberts, Thomas J; Azizi, Emanuel
2010-08-01
Elastic tendons can act as muscle power amplifiers or energy-conserving springs during locomotion. We used an in situ muscle-tendon preparation to examine the mechanical function of tendons during lengthening contractions, when muscles absorb energy. Force, length, and power were measured in the lateral gastrocnemius muscle of wild turkeys. Sonomicrometry was used to measure muscle fascicle length independently from muscle-tendon unit (MTU) length, as measured by a muscle lever system (servomotor). A series of ramp stretches of varying velocities was applied to the MTU in fully activated muscles. Fascicle length changes were decoupled from length changes imposed on the MTU by the servomotor. Under most conditions, muscle fascicles shortened on average, while the MTU lengthened. Energy input to the MTU during the fastest lengthenings was -54.4 J/kg, while estimated work input to the muscle fascicles during this period was only -11.24 J/kg. This discrepancy indicates that energy was first absorbed by elastic elements, then released to do work on muscle fascicles after the lengthening phase of the contraction. The temporary storage of energy by elastic elements also resulted in a significant attenuation of power input to the muscle fascicles. At the fastest lengthening rates, peak instantaneous power input to the MTU reached -2,143.9 W/kg, while peak power input to the fascicles was only -557.6 W/kg. These results demonstrate that tendons may act as mechanical buffers by limiting peak muscle forces, lengthening rates, and power inputs during energy-absorbing contractions.
Tidal stretches do not modulate responsiveness of intact airways in vitro
Szabo, Thomas L.; Suki, Béla; Lutchen, Kenneth R.
2010-01-01
Studies on isolated tracheal airway smooth muscle (ASM) strips have shown that length/force fluctuations, similar to those likely occurring during breathing, will mitigate ASM contractility. These studies conjecture that, solely by reducing length oscillations on a healthy, intact airway, one can create airway hyperresponsiveness, but this has never been explicitly tested. The intact airway has additional complexities of geometry and structure that may impact its relevance to isolated ASM strips. We examined the role of transmural pressure (Ptm) fluctuations of physiological amplitudes on the responsiveness of an intact airway. We developed an integrated system utilizing ultrasound imaging to provide real-time measurements of luminal radius and wall thickness over the full length of an intact airway (generation 10 and below) during Ptm oscillations. First, airway constriction dynamics to cumulative acetylcholine (ACh) doses (10−7 to 10−3 M) were measured during static and dynamic Ptm protocols. Regardless of the breathing pattern, the Ptm oscillation protocols were ineffective in reducing the net level of constriction for any ACh dose, compared with the static control (P = 0.225–0.793). Next, Ptm oscillations of increasing peak-to-peak amplitude were applied subsequent to constricting intact airways under static conditions (5.0-cmH2O Ptm) with a moderate ACh dose (10−5 M). Peak-to-peak Ptm oscillations ≤5.0 cmH2O resulted in no statistically significant bronchodilatory response (P = 0.429 and 0.490). Larger oscillations (10 cmH2O, peak to peak) produced modest dilation of 4.3% (P = 0.009). The lack of modulation of airway responsiveness by Ptm oscillations in intact, healthy airways suggests that ASM level mechanisms alone may not be the sole determinant of airway responsiveness. PMID:20431023
Non-destructive testing of full-length bonded rock bolts based on HHT signal analysis
NASA Astrophysics Data System (ADS)
Shi, Z. M.; Liu, L.; Peng, M.; Liu, C. C.; Tao, F. J.; Liu, C. S.
2018-04-01
Full-length bonded rock bolts are commonly used in mining, tunneling and slope engineering because of their simple design and resistance to corrosion. However, the length of a rock bolt and grouting quality do not often meet the required design standards in practice because of the concealment and complexity of bolt construction. Non-destructive testing is preferred when testing a rock bolt's quality because of the convenience, low cost and wide detection range. In this paper, a signal analysis method for the non-destructive sound wave testing of full-length bonded rock bolts is presented, which is based on the Hilbert-Huang transform (HHT). First, we introduce the HHT analysis method to calculate the bolt length and identify defect locations based on sound wave reflection test signals, which includes decomposing the test signal via empirical mode decomposition (EMD), selecting the intrinsic mode functions (IMF) using the Pearson Correlation Index (PCI) and calculating the instantaneous phase and frequency via the Hilbert transform (HT). Second, six model tests are conducted using different grouting defects and bolt protruding lengths to verify the effectiveness of the HHT analysis method. Lastly, the influence of the bolt protruding length on the test signal, identification of multiple reflections from defects, bolt end and protruding end, and mode mixing from EMD are discussed. The HHT analysis method can identify the bolt length and grouting defect locations from signals that contain noise at multiple reflected interfaces. The reflection from the long protruding end creates an irregular test signal with many frequency peaks on the spectrum. The reflections from defects barely change the original signal because they are low energy, which cannot be adequately resolved using existing methods. The HHT analysis method can identify reflections from the long protruding end of the bolt and multiple reflections from grouting defects based on mutations in the instantaneous frequency, which makes weak reflections more noticeable. The mode mixing phenomenon is observed in several tests, but this does not markedly affect the identification results due to the simple medium in bolt tests. The mode mixing can be reduced by ensemble EMD (EEMD) or complete ensemble EMD with adaptive noise (CEEMDAN), which are powerful tools to used analyze the test signal in a complex medium and may play an important role in future studies. The HHT bolt signal analysis method is a self-adaptive and automatic process, which can be programed as analysis software and will make bolt tests more convenient in practice.
Yamashita, Takehiro; Asaoka, Ryo; Kii, Yuya; Terasaki, Hiroto; Murata, Hiroshi; Sakamoto, Taiji
2017-01-01
The location of the peaks of the circumpapillary retinal nerve fiber layer (cpRNFL) thickness is affected by several ocular parameters. In this study, we have generated equations that can determine the peaks of the cpRNFL. This study was a prospective, observational, cross sectional study of 118 healthy right eyes. The axial length, optic disc tilt, superiortemporal (ST)- and inferiortemporal (IT)-peaks of the cpRNFL thickness, and angles of the ST and IT retinal arteries (RA) and veins (RV) were determined. The correlations between the location of the ST- and IT-peaks and ocular structural parameters and the sex, body height and weight were calculated. The best fit equations to generate the location of the ST/IT-peaks were determined using corrected-Akaike Information Criteria. The location of the ST-peak was 0.72+(0.40 x ST-RA)+(0.27 x ST-RV)+(0.14 x height)-(0.47 x papillo-macular-position)-(0.11 x disc tilt) with a coefficient of correlation of 0.61 (P<0.0001). The location of the IT-peak was 21.88+(0.53 x IT-RA)+(0.15 x IT-RV)+(0.041 x corneal thickness)-(1.00 x axial length) with a coefficient of correlation of 0.59 (P<0.0001). The location of ST/IT peaks is determined by different parameters of the ocular structure. These equations allow clinicians to obtain an accurate location of the peaks for a more accurate diagnosis of glaucoma.
Soft Biomimetic Fish Robot Made of Dielectric Elastomer Actuators.
Shintake, Jun; Cacucciolo, Vito; Shea, Herbert; Floreano, Dario
2018-06-29
This article presents the design, fabrication, and characterization of a soft biomimetic robotic fish based on dielectric elastomer actuators (DEAs) that swims by body and/or caudal fin (BCF) propulsion. BCF is a promising locomotion mechanism that potentially offers swimming at higher speeds and acceleration rates, and efficient locomotion. The robot consists of laminated silicone layers wherein two DEAs are used in an antagonistic configuration, generating undulating fish-like motion. The design of the robot is guided by a mathematical model based on the Euler-Bernoulli beam theory and takes account of the nonuniform geometry of the robot and of the hydrodynamic effect of water. The modeling results were compared with the experimental results obtained from the fish robot with a total length of 150 mm, a thickness of 0.75 mm, and weight of 4.4 g. We observed that the frequency peaks in the measured thrust force produced by the robot are similar to the natural frequencies computed by the model. The peak swimming speed of the robot was 37.2 mm/s (0.25 body length/s) at 0.75 Hz. We also observed that the modal shape of the robot at this frequency corresponds to the first natural mode. The swimming of the robot resembles real fish and displays a Strouhal number very close to those of living fish. These results suggest the high potential of DEA-based underwater robots relying on BCF propulsion, and applicability of our design and fabrication methods.
NASA Astrophysics Data System (ADS)
Sun, Chao; Deng, Jinxiang; Kong, Le; Chen, Liang; Shen, Zhen; Cao, Yisen; Zhang, Hao; Wang, Xiaoran
2017-12-01
This paper reported the β-Ga2O3 nanofibres which fabricated by electrospinning, and then calcining in oxygen at 750, 850, 950 and 1050°C. The structure and properties of β-Ga2O3 nanofibers have been studied though kinds of methods such as XRD, Photoluminescence (PL) spectrum, Raman spectrum, Scanning electron microscope (SEM) and FT-IR. The diameters of these nanofibres are from 60 to 130nm and the lengths of these nanofibres are about couple millimetres. The spectrum of PL which excitation at 365nm gave us the information that the emission peak of these β-Ga2O3 nanofibres is about 470nm, it may be coursed by the various defects including the vacancies of gallium and oxygen and the gallium-oxygen vacancy pairs as well, and observed that with the increasing of the annealing temperature, the emission peaks have a small bule swifting, and the crystallinity become better at the same time.
High precision optical fiber Fabry-Perot sensor for gas pressure detection
NASA Astrophysics Data System (ADS)
Mao, Yan; Tong, Xing-lin
2013-09-01
An optical fiber Fabry-Perot (F-P) sensor with quartz diaphragm for gas pressure testing was designed and fabricated. It consisted of single-mode fiber, hollow glass tube and quartz diaphragm. It uses the double peak demodulation to obtain the initialized cavity length. The variety of cavity length can be calcultated by the single peak demodulation after changing the gas pressure. The results show that the sensor is small in size, whose sensitivity is 19 pm/kPa in the range of the 10 ~ 260 kPa gas pressure. And it has good linearity and repeatability.
Anomalous Anderson localization
NASA Astrophysics Data System (ADS)
Deng, Wenji
2000-04-01
We propose a generalized Anderson model and study numerically the localization phenomena in one dimension. In our model, not all the sites take on-site random site energy. The on-site energy εn on the nth site is assigned as follows. If n+P-1=0 ( mod P) , where P is a positive integer, εn is assumed to be randomly distributed between - W/2 and W/2. On the other lattice sites, the site energy is fixed, say εn=0.The localization length ξ defined as | t| 2=e -2 L/ ξ, where t is the transmission coefficient, is calculated using the transfer matrix method. It is found that the single-electron states with wave vectors k= π/P, 2 π/P,…,(P-1) π/P are no longer localized as in the standard Anderson model. Compared with the smooth localization length spectrum of the Anderson model, there appear P-1 sharp peaks periodically located at P-1 values of wave vector on the localization length spectrum of the generalized Anderson model with parameter P.
NASA Astrophysics Data System (ADS)
Li, Tanda; Bedding, Timothy R.; Huber, Daniel; Ball, Warrick H.; Stello, Dennis; Murphy, Simon J.; Bland-Hawthorn, Joss
2018-03-01
Stellar models rely on a number of free parameters. High-quality observations of eclipsing binary stars observed by Kepler offer a great opportunity to calibrate model parameters for evolved stars. Our study focuses on six Kepler red giants with the goal of calibrating the mixing-length parameter of convection as well as the asteroseismic surface term in models. We introduce a new method to improve the identification of oscillation modes that exploits theoretical frequencies to guide the mode identification (`peak-bagging') stage of the data analysis. Our results indicate that the convective mixing-length parameter (α) is ≈14 per cent larger for red giants than for the Sun, in agreement with recent results from modelling the APOGEE stars. We found that the asteroseismic surface term (i.e. the frequency offset between the observed and predicted modes) correlates with stellar parameters (Teff, log g) and the mixing-length parameter. This frequency offset generally decreases as giants evolve. The two coefficients a-1 and a3 for the inverse and cubic terms that have been used to describe the surface term correction are found to correlate linearly. The effect of the surface term is also seen in the p-g mixed modes; however, established methods for correcting the effect are not able to properly correct the g-dominated modes in late evolved stars.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mandlik, Nandkumar, E-mail: ntmandlik@gmail.com; Patil, B. J.; Bhoraskar, V. N.
2014-04-24
Nanorods of CaSO{sub 4}: Dy having diameter 20 nm and length 200 nm have been synthesized by the chemical coprecipitation method. These samples were irradiated with gamma radiation for the dose varying from 0.1 Gy to 50 kGy and their TL characteristics have been studied. TL dose response shows a linear behavior up to 5 kGy and further saturates with increase in the dose. A Computerized Glow Curve Deconvolution (CGCD) program was used for the analysis of TL glow curves. Trapping parameters for various peaks have been calculated by using CGCD program.
NASA Astrophysics Data System (ADS)
Mandlik, Nandkumar; Patil, B. J.; Bhoraskar, V. N.; Sahare, P. D.; Dhole, S. D.
2014-04-01
Nanorods of CaSO4: Dy having diameter 20 nm and length 200 nm have been synthesized by the chemical coprecipitation method. These samples were irradiated with gamma radiation for the dose varying from 0.1 Gy to 50 kGy and their TL characteristics have been studied. TL dose response shows a linear behavior up to 5 kGy and further saturates with increase in the dose. A Computerized Glow Curve Deconvolution (CGCD) program was used for the analysis of TL glow curves. Trapping parameters for various peaks have been calculated by using CGCD program.
Prince, Linda M
2015-01-01
Inter-simple sequence repeat PCR (ISSR-PCR) is a fast, inexpensive genotyping technique based on length variation in the regions between microsatellites. The method requires no species-specific prior knowledge of microsatellite location or composition. Very small amounts of DNA are required, making this method ideal for organisms of conservation concern, or where the quantity of DNA is extremely limited due to organism size. ISSR-PCR can be highly reproducible but requires careful attention to detail. Optimization of DNA extraction, fragment amplification, and normalization of fragment peak heights during fluorescent detection are critical steps to minimizing the downstream time spent verifying and scoring the data.
Miyake, Fuyu; Suga, Rika; Akiyama, Takahiro; Namba, Fumihiko
2018-04-06
Neonates, particularly premature babies, are often managed with endotracheal intubation and subsequent mechanical ventilation to maintain adequate pulmonary gas exchange. There is no consensus on the standard length of endotracheal tube. Although a short tube reduces resistance and respiratory dead space, it is believed to increase the risk of accidental extubation. There are not entirely coherent data regarding the effect of endotracheal tube length on work of breathing in infants. The aim of this study was to evaluate the impact of neonatal endotracheal tube diameter and length on the work of breathing using an infant in vitro lung model. We assessed the work of breathing index and mechanical ventilation settings with various endotracheal tube diameters and lengths using the JTR100 in vitro infant lung model. The basic parameters of the model were breathing frequency of 20 per minutes, inspiratory-expiratory ratio of 1:3, and positive end-expiratory pressure of 5 cmH 2 O. In addition, the diaphragm driving pressure to maintain the set tidal volume was measured as the work of breathing index. The JTR100 was connected to the Babylog 8000plus through the endotracheal tube. Finally, we monitored the peak inspiratory pressure generated during assist-control volume guarantee mode with a targeted tidal volume of 10-30 mL. The diaphragm driving pressure using a 2.0-mm inner diameter tube was twice as high as that using a 4.0-mm inner diameter tube. To maintain the targeted tidal volume, a shorter tube reduced both the diaphragm driving pressure and ventilator-generated peak inspiratory pressure. The difference in the generated peak inspiratory pressure between the shortest and longest tubes was 5 cmH 2 O. In our infant lung model, a shorter tube resulted in a lower work of breathing and lower ventilator-generated peak inspiratory pressure. © 2018 John Wiley & Sons Ltd.
Dispersion-convolution model for simulating peaks in a flow injection system.
Pai, Su-Cheng; Lai, Yee-Hwong; Chiao, Ling-Yun; Yu, Tiing
2007-01-12
A dispersion-convolution model is proposed for simulating peak shapes in a single-line flow injection system. It is based on the assumption that an injected sample plug is expanded due to a "bulk" dispersion mechanism along the length coordinate, and that after traveling over a distance or a period of time, the sample zone will develop into a Gaussian-like distribution. This spatial pattern is further transformed to a temporal coordinate by a convolution process, and finally a temporal peak image is generated. The feasibility of the proposed model has been examined by experiments with various coil lengths, sample sizes and pumping rates. An empirical dispersion coefficient (D*) can be estimated by using the observed peak position, height and area (tp*, h* and At*) from a recorder. An empirical temporal shift (Phi*) can be further approximated by Phi*=D*/u2, which becomes an important parameter in the restoration of experimental peaks. Also, the dispersion coefficient can be expressed as a second-order polynomial function of the pumping rate Q, for which D*(Q)=delta0+delta1Q+delta2Q2. The optimal dispersion occurs at a pumping rate of Qopt=sqrt[delta0/delta2]. This explains the interesting "Nike-swoosh" relationship between the peak height and pumping rate. The excellent coherence of theoretical and experimental peak shapes confirms that the temporal distortion effect is the dominating reason to explain the peak asymmetry in flow injection analysis.
Photoelectric return-stroke velocity and peak current estimates in natural and triggered lightning
NASA Technical Reports Server (NTRS)
Mach, Douglas M.; Rust, W. David
1989-01-01
Two-dimensional photoelectric return stroke velocities from 130 strokes are presented, including 86 negative natural, 41 negative triggered, one positive triggered, and two positive natural return strokes. For strokes starting near the ground and exceeding 500 m in length, the average velocity is 1.3 + or - 0.3 X 10 to the 8th m/s for natural return strokes and 1.2 + or - 0.3 X 10 to the 8th m/s for triggered return strokes. For strokes with lengths less than 500 m, the average velocities are slightly higher. Using the transmission line model (TLM), the shortest segment one-dimensional return stroke velocity, and either the maximum or plateau electric field, it is shown that natural strokes have a peak current distribution that is lognormal with a median value of 16 kA (maximum E) or 12 kA (plateau E). Triggered lightning has a medium peak current value of 21 kA (maximum E) or 15 kA (plateau E). Correlations are found between TLM peak currents and velocities for triggered and natural subsequent return strokes, but not between TLM peak currents and natural first return stroke velocities.
Gait biomechanics of skipping are substantially different than those of running.
McDonnell, Jessica; Willson, John D; Zwetsloot, Kevin A; Houmard, Joseph; DeVita, Paul
2017-11-07
The inherit injury risk associated with high-impact exercises calls for alternative ways to achieve the benefits of aerobic exercise while minimizing excessive stresses to body tissues. Skipping presents such an alternative, incorporating double support, flight, and single support phases. We used ground reaction forces (GRFs), lower extremity joint torques and powers to compare skipping and running in 20 healthy adults. The two consecutive skipping steps on each limb differed significantly from each other, and from running. Running had the longest step length, the highest peak vertical GRF, peak knee extensor torque, and peak knee negative and positive power and negative and positive work. Skipping had the greater cadence, peak horizontal GRF, peak hip and ankle extensor torques, peak ankle negative power and work, and peak ankle positive power. The second vs first skipping step had the shorter step length, higher cadence, peak horizontal GRF, peak ankle extensor torque, and peak ankle negative power, negative work, and positive power and positive work. The first skipping step utilized predominately net negative joint work (eccentric muscle action) while the second utilized predominately net positive joint work (concentric muscle action). The skipping data further highlight the persistence of net negative work performed at the knee and net positive work performed at the ankle across locomotion gaits. Evidence of step segregation was seen in distribution of the braking and propelling impulses and net work produced across the hip, knee, and ankle joints. Skipping was substantially different than running and was temporally and spatially asymmetrical with successive foot falls partitioned into a dominant function, either braking or propelling whereas running had a single, repeated step in which both braking and propelling actions were performed equally. Copyright © 2017 Elsevier Ltd. All rights reserved.
The series-elastic shock absorber: tendons attenuate muscle power during eccentric actions
Azizi, Emanuel
2010-01-01
Elastic tendons can act as muscle power amplifiers or energy-conserving springs during locomotion. We used an in situ muscle-tendon preparation to examine the mechanical function of tendons during lengthening contractions, when muscles absorb energy. Force, length, and power were measured in the lateral gastrocnemius muscle of wild turkeys. Sonomicrometry was used to measure muscle fascicle length independently from muscle-tendon unit (MTU) length, as measured by a muscle lever system (servomotor). A series of ramp stretches of varying velocities was applied to the MTU in fully activated muscles. Fascicle length changes were decoupled from length changes imposed on the MTU by the servomotor. Under most conditions, muscle fascicles shortened on average, while the MTU lengthened. Energy input to the MTU during the fastest lengthenings was −54.4 J/kg, while estimated work input to the muscle fascicles during this period was only −11.24 J/kg. This discrepancy indicates that energy was first absorbed by elastic elements, then released to do work on muscle fascicles after the lengthening phase of the contraction. The temporary storage of energy by elastic elements also resulted in a significant attenuation of power input to the muscle fascicles. At the fastest lengthening rates, peak instantaneous power input to the MTU reached −2,143.9 W/kg, while peak power input to the fascicles was only −557.6 W/kg. These results demonstrate that tendons may act as mechanical buffers by limiting peak muscle forces, lengthening rates, and power inputs during energy-absorbing contractions. PMID:20507964
Precise measurement of ultra-narrow laser linewidths using the strong coherent envelope
NASA Astrophysics Data System (ADS)
Huang, Shihong; Zhu, Tao; Liu, Min; Huang, Wei
2017-02-01
Laser linewidth narrowing down to kHz or even Hz is an important topic in areas like clock synchronization technology, laser radars, quantum optics, and high-precision detection. Conventional decoherence measurement methods like delayed self-heterodyne/homodyne interferometry cannot measure such narrow linewidths accurately. This is because a broadening of the Gaussian spectrum, which hides the laser’s intrinsic Lorentzian linewidth, cannot be avoided. Here, we introduce a new method using the strong coherent envelope to characterize the laser’s intrinsic linewidth through self-coherent detection. This method can eliminate the effect of the broadened Gaussian spectrum induced by the 1/f frequency noise. We analyze, in detail, the relationship between intrinsic laser linewidth, contrast difference with the second peak and the second trough (CDSPST) of the strong coherent envelope, and the length of the delaying fiber. The correct length for the delaying fiber can be chosen by combining the estimated laser linewidth (Δfest) with a specific CDSPST (ΔS) to obtain the accurate laser linewidth (Δf). Our results indicate that this method can be used as an accurate detection tool for measurements of narrow or super-narrow linewidths.
Photoelectrochemical Stability and Alteration Products of n-Type Single-Crystal ZnO Photoanodes
Paulauskas, I. E.; Jellison, G. E.; Boatner, L. A.; ...
2011-01-01
The photoelectrochemical stability and surface-alteration characteristics of doped and undoped n-type ZnO single-crystal photoanode electrodes were investigated. The single-crystal ZnO photoanode properties were analyzed using current-voltage measurements plus spectral and time-dependent quantum-yield methods. These measurements revealed a distinct anodic peak and an accompanying cathodic surface degradation process at negative potentials. The features of this peak depended on time and the NaOH concentration in the electrolyte, but were independent of the presence of electrode illumination. Current measurements performed at the peak indicate that charging and discharging effects are apparently taking place at the semiconductor/electrolyte interface. This result is consistent with themore » significant reactive degradation that takes place on the ZnO single crystal photoanode surface and that ultimately leads to the reduction of the ZnO surface to Zn metal. The resulting Zn-metal reaction products create unusual, dendrite-like, surface alteration structural features that were analyzed using x-ray diffraction, energy-dispersive analysis, and scanning electron microscopy. ZnO doping methods were found to be effective in increasing the n-type character of the crystals. Higher doping levels result in smaller depletion widths and lower quantum yields, since the minority carrier diffusion lengths are very short in these materials.« less
Paget, John; Marquet, Richard; Meijer, Adam; van der Velden, Koos
2007-01-01
Background The European Influenza Surveillance Scheme (EISS) has collected clinical and virological data on influenza since 1996 in an increasing number of countries. The EISS dataset was used to characterise important epidemiological features of influenza activity in Europe during eight winters (1999–2007). The following questions were addressed: 1) are the sentinel clinical reports a good measure of influenza activity? 2) how long is a typical influenza season in Europe? 3) is there a west-east and/or south-north course of peak activity ('spread') of influenza in Europe? Methods Influenza activity was measured by collecting data from sentinel general practitioners (GPs) and reports by national reference laboratories. The sentinel reports were first evaluated by comparing them to the laboratory reports and were then used to assess the timing and spread of influenza activity across Europe during eight seasons. Results We found a good match between the clinical sentinel data and laboratory reports of influenza collected by sentinel physicians (overall match of 72% for +/- 1 week difference). We also found a moderate to good match between the clinical sentinel data and laboratory reports of influenza from non-sentinel sources (overall match of 60% for +/- 1 week). There were no statistically significant differences between countries using ILI (influenza-like illness) or ARI (acute respiratory disease) as case definition. When looking at the peak-weeks of clinical activity, the average length of an influenza season in Europe was 15.6 weeks (median 15 weeks; range 12–19 weeks). Plotting the peak weeks of clinical influenza activity reported by sentinel GPs against the longitude or latitude of each country indicated that there was a west-east spread of peak activity (spread) of influenza across Europe in four winters (2001–2002, 2002–2003, 2003–2004 and 2004–2005) and a south-north spread in three winters (2001–2002, 2004–2005 and 2006–2007). Conclusion We found that: 1) the clinical data reported by sentinel physicians is a valid indicator of influenza activity; 2) the length of influenza activity across the whole of Europe was surprisingly long, ranging from 12–19 weeks; 3) in 4 out of the 8 seasons, there was a west-east spread of influenza, in 3 seasons a south-north spread; not associated with type of dominant virus in those seasons. PMID:18047685
Optimal application of Morrison's iterative noise removal for deconvolution. Appendices
NASA Technical Reports Server (NTRS)
Ioup, George E.; Ioup, Juliette W.
1987-01-01
Morrison's iterative method of noise removal, or Morrison's smoothing, is applied in a simulation to noise-added data sets of various noise levels to determine its optimum use. Morrison's smoothing is applied for noise removal alone, and for noise removal prior to deconvolution. For the latter, an accurate method is analyzed to provide confidence in the optimization. The method consists of convolving the data with an inverse filter calculated by taking the inverse discrete Fourier transform of the reciprocal of the transform of the response of the system. Various length filters are calculated for the narrow and wide Gaussian response functions used. Deconvolution of non-noisy data is performed, and the error in each deconvolution calculated. Plots are produced of error versus filter length; and from these plots the most accurate length filters determined. The statistical methodologies employed in the optimizations of Morrison's method are similar. A typical peak-type input is selected and convolved with the two response functions to produce the data sets to be analyzed. Both constant and ordinate-dependent Gaussian distributed noise is added to the data, where the noise levels of the data are characterized by their signal-to-noise ratios. The error measures employed in the optimizations are the L1 and L2 norms. Results of the optimizations for both Gaussians, both noise types, and both norms include figures of optimum iteration number and error improvement versus signal-to-noise ratio, and tables of results. The statistical variation of all quantities considered is also given.
NASA Technical Reports Server (NTRS)
Wilson, Robert M.
2009-01-01
Yearly frequencies of North Atlantic basin tropical cyclones, their locations of origin, peak wind speeds, average peak wind speeds, lowest pressures, and average lowest pressures for the interval 1950-2008 are examined. The effects of El Nino and La Nina on the tropical cyclone parametric values are investigated. Yearly and 10-year moving average (10-yma) values of tropical cyclone parameters are compared against those of temperature and decadal-length oscillation, employing both linear and bi-variate analysis, and first differences in the 10-yma are determined. Discussion of the 2009 North Atlantic basin hurricane season, updating earlier results, is given.
Mass sensitivity studies for an inductively driven railgun
NASA Astrophysics Data System (ADS)
Scanlon, J. J., III; Young, A. F.
1991-01-01
Those areas which result in substantial system mass reductions for an HPG (homopolar generator) driven EML (electromagnetic launcher) are identified. Sensitivity studies are performed by varying launch mass, peak acceleration, launcher efficiency, inductance gradient, injection velocity, barrel mass per unit length, fuel tankage and pump estimates, and component energy and power densities. Two major contributors to the system mass are the allowed number of shots per barrel versus the number required for the mission, and the barrel length. The effects of component performance parameters, such as friction coefficient, injection velocity, ablation coefficient, rail resistivity, armature voltage, peak acceleration, and inductance gradient on these two areas, are addressed.
NASA Technical Reports Server (NTRS)
Kerschen, E. J.; Gliebe, P. R.
1980-01-01
An analytical model of fan noise caused by inflow turbulence, a generalization of earlier work by Mani, is presented. Axisymmetric turbulence theory is used to develop a statistical representation of the inflow turbulence valid for a wide range of turbulence properties. Both the dipole source due to rotor blade unsteady forces and the quadrupole source resulting from the interaction of the turbulence with the rotor potential field are considered. The effects of variations in turbulence properties and fan operating conditions are evaluated. For turbulence axial integral length scales much larger than the blade spacing, the spectrum is shown to consist of sharp peaks at the blade passing frequency and its harmonics, with negligible broadband content. The analysis can then be simplified considerably and the total sound power contained within each spectrum peak becomes independent of axial length scale, while the width of the peak is inversely proportional to this parameter. Large axial length scales are characteristic of static fan test facilities, where the transverse contraction of the inlet flow produces highly anisotropic turbulence. In this situation, the rotor/turbulence interaction noise is mainly caused by the transverse component of turbulent velocity.
Beeston, Michael Philip; Glass, Hylke Jan; van Elteren, Johannes Teun; Slejkovec, Zdenka
2007-09-19
A new method has been developed to analyse the mobility of elements within soils employing counter-current flow soil contacting in a fluidised bed (FB) column. This method alleviates the problem of irreproducible peaks suffered by state-of-the-art micro-column techniques as a result of particle compaction. Reproducible extraction profiles are produced through the leaching of soil with a linear gradient of 0.05 mol L(-1) ammonium sulphate to 0.11 mol L(-1) acetic acid using a high pressure liquid chromatography (HPLC) quaternary pump, and the continuous monitoring of the elements in the leachate with inductively coupled plasma mass spectrometry (ICP-MS). Quantification of the procedure is achieved with an external flow injection (FI) calibration method. Flow rate and FB column length were investigated as critical parameters to the efficiency of the extraction methodology. It was found that an increase in the column length from 10 to 20 cm using a flow rate of 0.15 mL min(-1) produced the same increase in extracted elemental concentration as an increase in flow rate from 0.15 to 0.30 mL min(-1). In both examples, the increase in the concentration of elements leached from the soil may be ascribed to the increase in the concentration gradient between the solid and liquid. The exhaustive nature of the technique defines the maximum leachable concentration within the operationally defined leaching parameters of the exchangeable phase, providing a more accurate assessment of the risk associated with the elements in the soil for the phase providing the greatest risk to the environment. The multi-elemental high sensitivity nature of the on-line detector provides an accurate determination of the associations present between the elements in the soil, and the identification of multiple phases within the exchangeable phase through the presence of multiple peaks in the extraction profiles. It is possible through the deconvolution of these extraction profiles that the concentration corresponding to the peaks identified can be defined.
NASA Astrophysics Data System (ADS)
Zhao, J.; Zhang, X.; Li, S.; Liu, C.; Chen, Y.; Peng, Y.; Zhu, Y.
2018-03-01
In this work, to decide the existence of terahertz (THz) wave propagation effect, THz pulses emitted from a blocked two-color femtosecond laser filament with variable length were recorded by a standard electric-optic sampling setup. The phenomenon of temporal advance of the THz waveform's peak with the increasing filament length has been observed. Together with another method of knife-edge measurement which aims at directly retrieving the THz beam diameter, both the experimental approaches have efficiently indicated the same filament range within which THz wave propagated inside the plasma column. At last, a preliminary two-dimensional near-field scanning imaging of the THz spot inside the cross section of the filament has been suggested as the third way to determine the issue of THz wave propagation effect.
Comparing the index-flood and multiple-regression methods using L-moments
NASA Astrophysics Data System (ADS)
Malekinezhad, H.; Nachtnebel, H. P.; Klik, A.
In arid and semi-arid regions, the length of records is usually too short to ensure reliable quantile estimates. Comparing index-flood and multiple-regression analyses based on L-moments was the main objective of this study. Factor analysis was applied to determine main influencing variables on flood magnitude. Ward’s cluster and L-moments approaches were applied to several sites in the Namak-Lake basin in central Iran to delineate homogeneous regions based on site characteristics. Homogeneity test was done using L-moments-based measures. Several distributions were fitted to the regional flood data and index-flood and multiple-regression methods as two regional flood frequency methods were compared. The results of factor analysis showed that length of main waterway, compactness coefficient, mean annual precipitation, and mean annual temperature were the main variables affecting flood magnitude. The study area was divided into three regions based on the Ward’s method of clustering approach. The homogeneity test based on L-moments showed that all three regions were acceptably homogeneous. Five distributions were fitted to the annual peak flood data of three homogeneous regions. Using the L-moment ratios and the Z-statistic criteria, GEV distribution was identified as the most robust distribution among five candidate distributions for all the proposed sub-regions of the study area, and in general, it was concluded that the generalised extreme value distribution was the best-fit distribution for every three regions. The relative root mean square error (RRMSE) measure was applied for evaluating the performance of the index-flood and multiple-regression methods in comparison with the curve fitting (plotting position) method. In general, index-flood method gives more reliable estimations for various flood magnitudes of different recurrence intervals. Therefore, this method should be adopted as regional flood frequency method for the study area and the Namak-Lake basin in central Iran. To estimate floods of various return periods for gauged catchments in the study area, the mean annual peak flood of the catchments may be multiplied by corresponding values of the growth factors, and computed using the GEV distribution.
Transmission characteristics of a subwavelength metallic slit with perpendicular groove
NASA Astrophysics Data System (ADS)
Jin, Li; Zhou, Jun; Zou, Weibo; Zhang, Haopeng; Zhang, Lingfen
2011-12-01
The transmission property of a subwavelength metallic slit with perpendicular groove is investigated by using finite element method. The lengths for the slits at both sides of the groove are set as the length of a metallic slit without groove at the surface plasmon fundamental mode resonance. In the grooved subwavelength metallic slit, enhanced transmission is found to be attributed to two kinds of resonance including surface plasmon waveguide resonance along the propagating direction and the transversely constructive interferential resonance. For the former resonance, integer antinodes of surface plasmon are formed in the groove. For the later resonance, there is a tradeoff between the maximum amplitude and the full width at half maximum of the transmitted peaks with the change of the groove width. And, the transmission enhancement of the grooved subwavelength metallic slit is related to the number of groove and the incident wavelength. Furthermore, the above resonances also exist in the structure whose lengths of metallic slits are set as the length of a slit without groove at the surface plasmon high-order mode resonance. By optimizing the geometric parameters, the transmission enhancement of the grooved subwavelength metallic slit as high as about 15367% is achieved.
NASA Astrophysics Data System (ADS)
Chatterjee, Tanmoy; Peet, Yulia T.
2017-07-01
A large eddy simulation (LES) methodology coupled with near-wall modeling has been implemented in the current study for high Re neutral atmospheric boundary layer flows using an exponentially accurate spectral element method in an open-source research code Nek 5000. The effect of artificial length scales due to subgrid scale (SGS) and near wall modeling (NWM) on the scaling laws and structure of the inner and outer layer eddies is studied using varying SGS and NWM parameters in the spectral element framework. The study provides an understanding of the various length scales and dynamics of the eddies affected by the LES model and also the fundamental physics behind the inner and outer layer eddies which are responsible for the correct behavior of the mean statistics in accordance with the definition of equilibrium layers by Townsend. An economical and accurate LES model based on capturing the near wall coherent eddies has been designed, which is successful in eliminating the artificial length scale effects like the log-layer mismatch or the secondary peak generation in the streamwise variance.
Xie, Shangran; Pang, Meng; Bao, Xiaoyi; Chen, Liang
2012-03-12
The dependence of Brillouin linewidth and peak frequency on lightwave state of polarization (SOP) due to fiber inhomogeneity in single mode fiber (SMF) is investigated by using Brillouin optical time domain analysis (BOTDA) system. Theoretical analysis shows fiber inhomogeneity leads to fiber birefringence and sound velocity variation, both of which can cause the broadening and asymmetry of the Brillouin gain spectrum (BGS) and thus contribute to the variation of Brillouin linewidth and peak frequency with lightwave SOP. Due to fiber inhomogeneity both in lateral profile and longitudinal direction, the measured BGS is the superposition of several spectrum components with different peak frequencies within the interaction length. When pump or probe SOP changes, both the peak Brillouin gain and the overlapping area of the optical and acoustic mode profile that determine the peak efficiency of each spectrum component vary within the interaction length, which further changes the linewidth and peak frequency of the superimposed BGS. The SOP dependence of Brillouin linewidth and peak frequency was experimentally demonstrated and quantified by measuring the spectrum asymmetric factor and fitting obtained effective peak frequency respectively via BOTDA system on standard step-index SMF-28 fiber. Experimental results show that on this fiber the Brillouin spectrum asymmetric factor and effective peak frequency vary in the range of 2% and 0.06MHz respectively over distance with orthogonal probe input SOPs. Experimental results also show that in distributed fiber Brillouin sensing, polarization scrambler (PS) can be used to reduce the SOP dependence of Brillouin linewidth and peak frequency caused by fiber inhomogeneity in lateral profile, however it maintains the effects caused by fiber inhomogeneity in longitudinal direction. In the case of non-ideal polarization scrambling using practical PS, the fluctuation of effective Brillouin peak frequency caused by fiber inhomogeneity provides another limit of sensing frequency resolution of distributed fiber Brillouin sensor.
Liu, Yinglin; Liu, Yukun; Li, Xuejiao; Jiao, Xuedan; Zhang, Rui; Zhang, Jianping
2016-10-01
To examine peak serum levels of the β-subunit of human chorionic gonadotropin (β-hCG) for prediction of early pregnancy outcomes among women with recurrent spontaneous abortion (RSA). In a retrospective study, the medical records of pregnant women with a history of RSA treated at Sun Yat-sen Memorial Hospital, China, between January 2011 and July 2013 were reviewed. Serum β-hCG had been measured twice weekly from 5 to 13weeks of pregnancy, and pregnancy was monitored by transvaginal ultrasonography to 13(+6)weeks. Optimal cutoff for peak β-hCG level was determined by receiver operator characteristic curve analysis and Youden index. Women were divided into four groups on the basis of optimal peak β-hCG cutoff and pregnancy outcome (pregnancy at 13weeks or spontaneous abortion). Peak β-hCG levels and length of pregnancy at this peak were examined. Overall, 1240 patients were included. The optimal cutoff value of peak β-hCG was 88 468IU/L, with a sensitivity, specificity, positive predictive value, and negative predictive value for successful pregnancy of 95.6%, 88.0%, 95.6%, and 89.0%, respectively. A faster rise in β-hCG, higher peak β-hCG, and longer pregnancy length at peak β-hCG were associated with successful early pregnancy. A cutoff value of serum β-hCG of 88 000IU/L could be used to predict early pregnancy outcomes for women with a history of RSA. Copyright © 2016. Published by Elsevier Ireland Ltd.
Reimeringer, M; Nuño, N; Desmarais-Trépanier, C; Lavigne, M; Vendittoli, P A
2013-01-01
One of the crucial factors for short- and long-term clinical success of total hip arthroplasty cementless implants is primary stability. Indeed, motion at the bone-implant interface above 40 μm leads to partial bone ingrowth, while motion exceeding 150 μm completely inhibits bone ingrowth. The aim of this study was to investigate the effect of two cementless femoral stem designs with different lengths on the primary stability. A finite element model of a composite Sawbones(®) fourth generation, implanted with five lengths of the straight prosthesis design and four lengths of the curved prosthesis design, was loaded with hip joint and abductor forces representing two physiological activities: fast walking and stair climbing. We found that reducing the straight stem length from 146 to 54 mm increased the average micromotion from 17 to 52 μm during fast walking, while the peak value increased from 42 to 104 μm. With the curved stem, reducing length from 105 to 54 mm increased the average micromotion from 10 to 29 μm, while the peak value increased from 37 to 101 μm. Similar findings are obtained for stair climbing for both stems. Although the present study showed that femoral stem length as well as stem design directly influences its primary stability, for the two femoral stems tested, length could be reduced substantially without compromising the primary stability. With the aim of minimising surgical invasiveness, newer femoral stem design and currently well performing stems might be used with a reduced length without compromising primary stability and hence, long-term survivorship.
Effects of step length and step frequency on lower-limb muscle function in human gait.
Lim, Yoong Ping; Lin, Yi-Chung; Pandy, Marcus G
2017-05-24
The aim of this study was to quantify the effects of step length and step frequency on lower-limb muscle function in walking. Three-dimensional gait data were used in conjunction with musculoskeletal modeling techniques to evaluate muscle function over a range of walking speeds using prescribed combinations of step length and step frequency. The body was modeled as a 10-segment, 21-degree-of-freedom skeleton actuated by 54 muscle-tendon units. Lower-limb muscle forces were calculated using inverse dynamics and static optimization. We found that five muscles - GMAX, GMED, VAS, GAS, and SOL - dominated vertical support and forward progression independent of changes made to either step length or step frequency, and that, overall, changes in step length had a greater influence on lower-limb joint motion, net joint moments and muscle function than step frequency. Peak forces developed by the uniarticular hip and knee extensors, as well as the normalized fiber lengths at which these muscles developed their peak forces, correlated more closely with changes in step length than step frequency. Increasing step length resulted in larger contributions from the hip and knee extensors and smaller contributions from gravitational forces (limb posture) to vertical support. These results provide insight into why older people with weak hip and knee extensors walk more slowly by reducing step length rather than step frequency and also help to identify the key muscle groups that ought to be targeted in exercise programs designed to improve gait biomechanics in older adults. Copyright © 2017 Elsevier Ltd. All rights reserved.
Zheng, Hanrong; Fang, Zujie; Wang, Zhaoyong; Lu, Bin; Cao, Yulong; Ye, Qing; Qu, Ronghui; Cai, Haiwen
2018-01-31
It is a basic task in Brillouin distributed fiber sensors to extract the peak frequency of the scattering spectrum, since the peak frequency shift gives information on the fiber temperature and strain changes. Because of high-level noise, quadratic fitting is often used in the data processing. Formulas of the dependence of the minimum detectable Brillouin frequency shift (BFS) on the signal-to-noise ratio (SNR) and frequency step have been presented in publications, but in different expressions. A detailed deduction of new formulas of BFS variance and its average is given in this paper, showing especially their dependences on the data range used in fitting, including its length and its center respective to the real spectral peak. The theoretical analyses are experimentally verified. It is shown that the center of the data range has a direct impact on the accuracy of the extracted BFS. We propose and demonstrate an iterative fitting method to mitigate such effects and improve the accuracy of BFS measurement. The different expressions of BFS variances presented in previous papers are explained and discussed.
Hindlimb immobilization - Length-tension and contractile properties of skeletal muscle
NASA Technical Reports Server (NTRS)
Witzmann, F. A.; Kim, D. H.; Fitts, R. H.
1982-01-01
Casts were placed around rat feet in plantar flexion position to immobilize the soleus muscle in a shortened position, while the other foot was fixed in dorsal flexion to set the extensor digitorum longus in a shortened position. The total muscular atrophy and contractile properties were measured at 1, 2, 4, 7, 14, 21, 28, 35, and 42 days after immobilization, with casts being replaced every two weeks. The slow twitch soleus and the fast-twitch vastus lateralis and longus muscles were excised after termination of the experiment. The muscles were then stretched and subjected to electric shock to elicit peak tetanic tension and peak tetanic tension development. Force velocity features of the three muscles were assayed in a series of afterloaded contractions and fiber lengths were measured from subsequently macerated muscle. All muscles atrophied during immobilization, reaching a new steady state by day 21. Decreases in fiber and sarcomere lengths were also observed.
Effect of lateral wedge length on ambulatory knee kinetics.
Fischer, Arielle G; Ulrich, Baptiste; Hoffmann, Laurent; Jolles, Brigitte M; Favre, Julien
2018-04-27
Lateral wedge insoles (LWI) were proposed to treat medial knee osteoarthritis through reductions of the ambulatory knee adduction moment (KAM). Limited attention was however paid to the LWI length, resulting in unclear understanding of its effect on KAM reductions. The knee flexion moment (KFM) was also shown to be important in knee osteoarthritis, but little is known about the effect of LWI length on it. This study aimed to compare the KAM and KFM of healthy subjects walking with four different lengths of LWI, explicitly without LWI and with LWI below the hindfoot (HF), below the hindfoot and forefoot (HF + FF) and below the hindfoot, forefoot and hallux (HF + FF + HX) segments. Nineteen healthy participants (63% male; 24 ± 3 years old) walked in an instrumented gait lab with LWI of four different lengths. Repeated one-way ANOVAs and post-hoc t-tests were used to compare knee kinetics among LWI lengths. The peak value of the KAM during the first half of stance and the KAM impulse differed with respect to the LWI length (p < 0.001). A length of at least HF + FF, but not necessarily longer, was needed to decrease both KAM parameters compared to walking without LWI. The LWI length had no effect on the peak value of the KFM during the first half of stance (p = 0.86). The results in this study could contribute to better selections of LWI for medial knee osteoarthritis and suggested that the length of the LWI could be a critical factor that should be considered in future research. Copyright © 2018 Elsevier B.V. All rights reserved.
Effect of hoof boots and toe-extension shoes on the forelimb kinetics of horses during walking.
Amitrano, Fernando N; Gutierrez-Nibeyro, Santiago D; Schaeffer, David J
2016-05-01
OBJECTIVE To determine and compare the effect of hoof boots (HBs) and shoes with a toe extension on stance duration, ground reaction force, and sole length in contact with the ground in nonlame horses during walking. ANIMALS 6 nonlame Standardbreds. PROCEDURES Force plate gait analyses of the forelimbs were performed while the horses were walking barefoot before manipulation of feet (baseline), while the horses were walking fitted with HBs, while the horses were walking shod with toe-extension shoes, and while the horses were walking barefoot after shoe removal. Horses underwent radiography of both forelimb feet to determine the sole length in contact with the ground when barefoot, wearing HBs, and shod with toe-extension shoes. Stance duration, ground reaction force, and sole length were compared among the various walking sessions. RESULTS Compared with baseline findings, stance duration increased significantly when horses were fitted with HBs (7%) or toe-extension shoes (5%). Peak forelimb ground reaction force was similar among walking sessions; however, time of braking force peak was significantly greater during the stance phase only when horses wore HBs. Also, the sole length in contact with the ground was significantly longer in horses fitted with HBs (14.3 cm) or shod with the toe-extension shoes (17.6 cm), compared with that for one of the barefoot hooves (12.7 cm). CONCLUSIONS AND CLINICAL RELEVANCE In nonlame horses, use of HBs prolonged the stance time and time of braking force peak, which is indicative of a slower deceleration phase during limb impact with the ground. Also, the use of HBs prolonged the deceleration phase of the stride and increased the sole length in contact with the ground.
El-Sherbiny, Mohsen M; Al-Aidaroos, Ali M
2014-01-01
The calanoid copepod, Acartiabispinosa Carl, 1907, is reported for the first time in the Red Sea, where it is found to be an important copepod in the mesozooplankton community structure of the Sharm El-Maya Bay. Female and male are fully redescribed and illustrated of as the mouthparts of this species have never previously been described and figured. Acartiabispinosa was collected in the plankton samples throughout the year and showed two peaks of abundance, a pronounced one in April (4234 individuals m(-3)), and second smaller peak during November (1784 individuals m(-3)). The average total length of females varied between 1.32 and 1.53 mm at the end of June and January respectively. For males, the average total length fluctuated between 1.07 and 1.16 mm at end of June and March respectively. Temperature showed an inverse relationship with the body length (P > 0.001) and seemed to be one of the prime factors affecting the body length of both sexes.
Luk, Keith D K; Saw, Lim Beng; Grozman, Samuel; Cheung, Kenneth M C; Samartzis, Dino
2014-02-01
Assessment of skeletal maturity in patients with adolescent idiopathic scoliosis (AIS) is important to guide clinical management. Understanding growth peak and cessation is crucial to determine clinical observational intervals, timing to initiate or end bracing therapy, and when to instrument and fuse. The commonly used clinical or radiologic methods to assess skeletal maturity are still deficient in predicting the growth peak and cessation among adolescents, and bone age is too complicated to apply. To address these concerns, we describe a new distal radius and ulna (DRU) classification scheme to assess skeletal maturity. A prospective study. One hundred fifty young, female AIS patients with hand x-rays and no previous history of spine surgery from a single institute were assessed. Radius and ulna plain radiographs, and various anthropomorphic parameters were assessed. We identified various stages of radius and ulna epiphysis maturity, which were graded as R1-R11 for the radius and U1-U9 for the ulna. The bone age, development of sexual characteristics, standing height, sitting height, arm span, radius length, and tibia length were studied prospectively at each stage of these epiphysis changes. Standing height, sitting height, and arm span growth were at their peak during stages R7 (mean, 11.4 years old) and U5 (mean, 11.0 years old). The long bone growths also demonstrated a common peak at R7 and U5. Cessation of height and arm span growth was noted after stages R10 (mean, 15.6 years old) and U9 (mean, 17.3 years old). The new DRU classification is a practical and easy-to-use scheme that can provide skeletal maturation status. This classification scheme provides close relationship with adolescent growth spurt and cessation of growth. This classification may have a tremendous utility in improving clinical-decision making in the conservative and operative management of scoliosis patients. Copyright © 2014 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Lu, Hua; Yue, Zengqi; Zhao, Jianlin
2018-05-01
We propose and investigate a new kind of bandpass filters based on the plasmonically induced transparency (PIT) effect in a special metal-insulator-metal (MIM) waveguide system. The finite element method (FEM) simulations illustrate that the obvious PIT response can be generated in the metallic nanostructure with the stub and coupled cavities. The lineshape and position of the PIT peak are particularly dependent on the lengths of the stub and coupled cavities, the waveguide width, as well as the coupling distance between the stub and coupled cavities. The numerical simulations are in accordance with the results obtained by the temporal coupled-mode theory. The multi-peak PIT effect can be achieved by integrating multiple coupled cavities into the plasmonic waveguide. This PIT response contributes to the flexible realization of chip-scale multi-channel bandpass filters, which could find crucial applications in highly integrated optical circuits for signal processing.
Engineering photonic nanojet by a graded-index micro-cuboid
NASA Astrophysics Data System (ADS)
Liu, Cheng-Yang; Yen, Tzu-Ping; Minin, Oleg V.; Minin, Igor V.
2018-04-01
In the present paper the basic characteristics (length, peak intensity, and full-width half-maximum) of nanojets formed in the vicinity of dielectric core-shell cuboids with different types of index grading are investigated by finite-difference time domain method. The latitudinal and longitudinal sizes of a nanojet and its peak intensity depending on the optical contrast variation of cuboids core-shells are numerically investigated. It has been shown that it is possible to control and elongate the nanojet abnormally. It also was shown that graded cuboid with dimensions of 4 × 4 × 4 wavelength may has FWHM of a jet less than uniform cuboid with dimensions of 1 × 1 × 1 wavelength. At wavelength of 600 nm graded index cuboid with dimensions of 4 × 4 × 4 wavelength and index grading = 2 allow to form photonic jet with FWHM about 232 nm or 0.39 wavelength.
Linslal, C L; Mohan, P M S; Halder, A; Gangopadhyay, T K
2012-06-01
The core-mode cutoff plays a major role in evanescent field absorption based sensors. A method has been proposed to calculate the core-mode cutoff by solving the eigenvalue equations of a weakly guiding three layer optical waveguide graphically. The variation of normalized waveguide parameter (V) is also calculated with different wavelengths at core-mode cutoff. At the first step, theoretical analysis of tapered fiber parameters has been performed for core-mode cutoff. The taper angle of an adiabatic tapered fiber is also analyzed using the length-scale criterion. Secondly, single-mode tapered fiber has been developed to make a precision sensor element suitable for chemical detection. Finally, the sensor element has been used to detect absorption peak of ethylenediamine. Results are presented in which an absorption peak at 1540 nm is observed.
Sun, Gao-Fei; He, Shou-Pu; Du, Xiong-Ming
2013-10-01
Cotton genomic studies have boomed since the release of Gossypium raimondii draft genome. In this study, cis-regulatory element (CRE) in 1 kb length sequence upstream 5' UTR of annotated genes were selected and scanned in the Arabidopsis thaliana (At) and Gossypium raimondii (Gr) genomes, based on the database of PLACE (Plant cis-acting Regulatory DNA Elements). According to the definition of this study, 44 (12.3%) and 57 (15.5%) CREs presented "peak-like" distribution in the 1 kb selected sequences of both genomes, respectively. Thirty-four of them were peak-like distributed in both genomes, which could be further categorized into 4 types based on their core sequences. The coincidence of TATABOX peak position and their actual position ((-) -30 bp) indicated that the position of a common CRE was conservative in different genes, which suggested that the peak position of these CREs was their possible actual position of transcription factors. The position of a common CRE was also different between the two genomes due to stronger length variation of 5' UTR in Gr than At. Furthermore, most of the peak-like CREs were located in the region of -110 bp-0 bp, which suggested that concentrated distribution might be conductive to the interaction of transcription factors, and then regulate the gene expression in downstream.
Korte, F Steven; McDonald, Kerry S
2007-01-01
The effects of sarcomere length (SL) on sarcomeric loaded shortening velocity, power output and rates of force development were examined in rat skinned cardiac myocytes that contained either α-myosin heavy chain (α-MyHC) or β-MyHC at 12 ± 1°C. When SL was decreased from 2.3 μm to 2.0 μm submaximal isometric force decreased ∼40% in both α-MyHC and β-MyHC myocytes while peak absolute power output decreased 55% in α-MyHC myocytes and 70% in β-MyHC myocytes. After normalization for the fall in force, peak power output decreased about twice as much in β-MyHC as in α-MyHC myocytes (41%versus 20%). To determine whether the fall in normalized power was due to the lower force levels, [Ca2+] was increased at short SL to match force at long SL. Surprisingly, this led to a 32% greater peak normalized power output at short SL compared to long SL in α-MyHC myocytes, whereas in β-MyHC myocytes peak normalized power output remained depressed at short SL. The role that interfilament spacing plays in determining SL dependence of power was tested by myocyte compression at short SL. Addition of 2% dextran at short SL decreased myocyte width and increased force to levels obtained at long SL, and increased peak normalized power output to values greater than at long SL in both α-MyHC and β-MyHC myocytes. The rate constant of force development (ktr) was also measured and was not different between long and short SL at the same [Ca2+] in α-MyHC myocytes but was greater at short SL in β-MyHC myocytes. At short SL with matched force by either dextran or [Ca2+], ktr was greater than at long SL in both α-MyHC and β-MyHC myocytes. Overall, these results are consistent with the idea that an intrinsic length component increases loaded crossbridge cycling rates at short SL and β-MyHC myocytes exhibit a greater sarcomere length dependence of power output. PMID:17347271
NASA Astrophysics Data System (ADS)
Hosoki, Ai; Nishiyama, Michiko; Choi, Yongwoon; Watanabe, Kazuhiro
2011-05-01
In this paper, we propose discrimination method between a moving human and object by means of a hetero-core fiber smart mat sensor which induces the optical loss change in time. In addition to several advantages such as flexibility, thin size and resistance to electro-magnetic interference for a fiber optic sensor, a hetero-core fiber optic sensor is sensitive to bending action of the sensor portion and independent of temperature fluctuations. Therefore, the hetero-core fiber thin mat sensor can have a fewer sensing portions than the conventional floor pressure sensors, furthermore, can detect the wide area covering the length of strides. The experimental results for human walking tests showed that the mat sensors were reproducibly working in real-time under limiting locations the foot passed in the mat sensor. Focusing on the temporal peak numbers in the optical loss, human walking and wheeled platform moving action induced the peak numbers in the range of 1 - 3 and 5 - 7, respectively, for the 10 persons including 9 male and 1 female. As a result, we conclude that the hetero-core fiber mat sensor is capable of discriminating between the moving human and object such as a wheeled platform focusing on the peak numbers in the temporal optical loss.
Meyers, Robert W; Oliver, Jon L; Hughes, Michael G; Lloyd, Rhodri S; Cronin, John B
2017-04-01
Meyers, RW, Oliver, JL, Hughes, MG, Lloyd, RS, and Cronin, JB. Influence of age, maturity, and body size on the spatiotemporal determinants of maximal sprint speed in boys. J Strength Cond Res 31(4): 1009-1016, 2017-The aim of this study was to investigate the influence of age, maturity, and body size on the spatiotemporal determinants of maximal sprint speed in boys. Three-hundred and seventy-five boys (age: 13.0 ± 1.3 years) completed a 30-m sprint test, during which maximal speed, step length, step frequency, contact time, and flight time were recorded using an optical measurement system. Body mass, height, leg length, and a maturity offset represented somatic variables. Step frequency accounted for the highest proportion of variance in speed (∼58%) in the pre-peak height velocity (pre-PHV) group, whereas step length explained the majority of the variance in speed (∼54%) in the post-PHV group. In the pre-PHV group, mass was negatively related to speed, step length, step frequency, and contact time; however, measures of stature had a positive influence on speed and step length yet a negative influence on step frequency. Speed and step length were also negatively influence by mass in the post-PHV group, whereas leg length continued to positively influence step length. The results highlighted that pre-PHV boys may be deemed step frequency reliant, whereas those post-PHV boys may be marginally step length reliant. Furthermore, the negative influence of body mass, both pre-PHV and post-PHV, suggests that training to optimize sprint performance in youth should include methods such as plyometric and strength training, where a high neuromuscular focus and the development force production relative to body weight are key foci.
Obtaining reliable phase-gradient delays from otoacoustic emission data.
Shera, Christopher A; Bergevin, Christopher
2012-08-01
Reflection-source otoacoustic emission phase-gradient delays are widely used to obtain noninvasive estimates of cochlear function and properties, such as the sharpness of mechanical tuning and its variation along the length of the cochlear partition. Although different data-processing strategies are known to yield different delay estimates and trends, their relative reliability has not been established. This paper uses in silico experiments to evaluate six methods for extracting delay trends from reflection-source otoacoustic emissions (OAEs). The six methods include both previously published procedures (e.g., phase smoothing, energy-weighting, data exclusion based on signal-to-noise ratio) and novel strategies (e.g., peak-picking, all-pass factorization). Although some of the methods perform well (e.g., peak-picking), others introduce substantial bias (e.g., phase smoothing) and are not recommended. In addition, since standing waves caused by multiple internal reflection can complicate the interpretation and compromise the application of OAE delays, this paper develops and evaluates two promising signal-processing strategies, the first based on time-frequency filtering using the continuous wavelet transform and the second on cepstral analysis, for separating the direct emission from its subsequent reflections. Altogether, the results help to resolve previous disagreements about the frequency dependence of human OAE delays and the sharpness of cochlear tuning while providing useful analysis methods for future studies.
The value of shoe size for prediction of the timing of the pubertal growth spurt
2011-01-01
Background Knowing the timing of the pubertal growth spurt of the spine, represented by sitting height, is essential for the prognosis and therapy of adolescent idiopathic scoliosis. There are several indicators that reflect growth or remaining growth of the patient. For example, distal body parts have their growth spurt earlier in adolescence, and therefore the growth of the foot can be an early indicator for the growth spurt of sitting height. Shoe size is a good alternative for foot length, since patients can remember when they bought new shoes and what size these shoes were. Therefore the clinician already has access to some longitudinal data at the first visit of the patient to the outpatient clinic. The aim of this study was to describe the increase in shoe size during adolescence and to determine whether the timing of the peak increase could be an early indicator for the timing of the peak growth velocity of sitting height. Methods Data concerning shoe sizes of girls and boys were acquired from two large shoe shops from 1991 to 2008. The longitudinal series of 242 girls and 104 boys were analysed for the age of the "peak increase" in shoe size, as well as the age of cessation of foot growth based on shoe size. Results The average peak increase in shoe size occurred at 10.4 years (SD 1.1) in girls and 11.5 years (SD 1.5) in boys. This was on average 1.3 years earlier than the average peak growth velocity of sitting height in girls, and 2.5 years earlier in boys. The increase in shoe size diminishes when the average peak growth velocity of sitting height takes place at respectively 12.0 (SD 0.8) years in girls, and 13.7 (SD 1.0) years in boys. Conclusions Present data suggest that the course of the shoe size of children visiting the outpatient clinic can be a useful first tool for predicting the timing of the pubertal growth spurt of sitting height, as a representative for spinal length. This claim needs verification by direct comparison of individual shoe size and sitting height data and than a step forward can be made in clinical decision making regarding adolescent idiopathic scoliosis. PMID:21251310
NASA Astrophysics Data System (ADS)
Karlsen, P.; Shuba, M. V.; Beckerleg, C.; Yuko, D. I.; Kuzhir, P. P.; Maksimenko, S. A.; Ksenevich, V.; Viet, Ho; Nasibulin, A. G.; Tenne, R.; Hendry, E.
2018-01-01
We measure the conductivity spectra of thin films comprising bundled single-walled carbon nanotubes (CNTs) of different average lengths in the frequency range 0.3-1000 THz and temperature interval 10-530 K. The observed temperature-induced changes in the terahertz conductivity spectra are shown to depend strongly on the average CNT length, with a conductivity around 1 THz that increases/decreases as the temperature increases for short/long tubes. This behaviour originates from the temperature dependence of the electron scattering rate, which we obtain from Drude fits of the measured conductivity in the range 0.3-2 THz for 10 μm length CNTs. This increasing scattering rate with temperature results in a subsequent broadening of the observed THz conductivity peak at higher temperatures and a shift to lower frequencies for increasing CNT length. Finally, we show that the change in conductivity with temperature depends not only on tube length, but also varies with tube density. We record the effective conductivities of composite films comprising mixtures of WS2 nanotubes and CNTs versus CNT density for frequencies in the range 0.3-1 THz, finding that the conductivity increases/decreases for low/high density films as the temperature increases. This effect arises due to the density dependence of the effective length of conducting pathways in the composite films, which again leads to a shift and temperature dependent broadening of the THz conductivity peak.
Butterfield, Timothy A; Herzog, Walter
2006-05-01
Muscle strain injuries are some of the most frequent injuries in sports and command a great deal of attention in an effort to understand their etiology. These injuries may be the culmination of a series of subcellular events accumulated through repetitive lengthening (eccentric) contractions during exercise, and they may be influenced by a variety of variables including fiber strain magnitude, peak joint torque, and starting muscle length. To assess the influence of these variables on muscle injury magnitude in vivo, we measured fiber dynamics and joint torque production during repeated stretch-shortening cycles in the rabbit tibialis anterior muscle, at short and long muscle lengths, while varying the timing of activation before muscle stretch. We found that a muscle subjected to repeated stretch-shortening cycles of constant muscle-tendon unit excursion exhibits significantly different joint torque and fiber strains when the timing of activation or starting muscle length is changed. In particular, measures of fiber strain and muscle injury were significantly increased by altering activation timing and increasing the starting length of the muscle. However, we observed differential effects on peak joint torque during the cyclic stretch-shortening exercise, as increasing the starting length of the muscle did not increase torque production. We conclude that altering activation timing and muscle length before stretch may influence muscle injury by significantly increasing fiber strain magnitude and that fiber dynamics is a more important variable than muscle-tendon unit dynamics and torque production in influencing the magnitude of muscle injury.
Transverse magnetic focussing of heavy holes in a (100) GaAs quantum well
NASA Astrophysics Data System (ADS)
Rendell, M.; Klochan, O.; Srinivasan, A.; Farrer, I.; Ritchie, D. A.; Hamilton, A. R.
2015-10-01
We perform magnetic focussing of high mobility holes confined in a shallow GaAs/Al0.33Ga0.67As quantum well grown on a (100) GaAs substrate. We observe ballistic focussing of holes over a path length of up to 4.9 μm with a large number of focussing peaks. We show that additional structure on the focussing peaks can be caused by a combination of the finite width of the injector quantum point contact and Shubnikov-de Haas oscillations. These results pave the way to studies of spin-dependent magnetic focussing and spin relaxation lengths in two-dimentional hole systems without complications of crystal anisotropies and anisotropic g-tensors.
Interlayer tunneling in double-layer quantum hall pseudoferromagnets.
Balents, L; Radzihovsky, L
2001-02-26
We show that the interlayer tunneling I-V in double-layer quantum Hall states displays a rich behavior which depends on the relative magnitude of sample size, voltage length scale, current screening, disorder, and thermal lengths. For weak tunneling, we predict a negative differential conductance of a power-law shape crossing over to a sharp zero-bias peak. An in-plane magnetic field splits this zero-bias peak, leading instead to a "derivative" feature at V(B)(B(parallel)) = 2 pi Planck's over 2 pi upsilon B(parallel)d/e phi(0), which gives a direct measurement of the dispersion of the Goldstone mode corresponding to the spontaneous symmetry breaking of the double-layer Hall state.
Fleischer, Adam E; Hshieh, Shenche; Crews, Ryan T; Waverly, Brett J; Jones, Jacob M; Klein, Erin E; Weil, Lowell; Weil, Lowell Scott
2018-05-01
Metatarsal length is believed to play a role in plantar plate dysfunction, although the mechanism through which progressive injury occurs is still uncertain. We aimed to clarify whether length of the second metatarsal was associated with increased plantar pressure measurements in the forefoot while walking. Weightbearing radiographs and corresponding pedobarographic data from 100 patients in our practice walking without a limp were retrospectively reviewed. Radiographs were assessed for several anatomic relationships, including metatarsal length, by a single rater. Pearson correlation analyses and multiple linear regression models were used to determine whether metatarsal length was associated with forefoot loading parameters. The relative length of the second to first metatarsal was positively associated with the ratio of peak pressure beneath the respective metatarsophalangeal joints ( r = 0.243, P = .015). The relative length of the second to third metatarsal was positively associated with the ratios of peak pressure ( r = 0.292, P = .003), pressure-time integral ( r = 0.249, P = .013), and force-time integral ( r = 0.221, P = .028) beneath the respective metatarsophalangeal joints. Although the variability in loading predicted by the various regression analyses was not large (4%-14%), the relative length of the second metatarsal (to the first and to the third) was maintained in each of the multiple regression models and remained the strongest predictor (highest standardized β-coefficient) in each of the models. Patients with longer second metatarsals exhibited relatively higher loads beneath the second metatarsophalangeal joint during barefoot walking. These findings provide a mechanism through which elongated second metatarsals may contribute to plantar plate injuries. Level III, comparative study.
Milner, Clare E; Meardon, Stacey A; Hawkins, Jillian L; Willson, John D
2018-04-28
Knee osteoarthritis is a major public health problem and adults with obesity are particularly at risk. One approach to alleviating this problem is to reduce the mechanical load at the joint during daily activity. Adjusting temporospatial parameters of walking could mitigate cumulative knee joint mechanical loads. The purpose of this study was to determine how adjustments to velocity and step length affects knee joint loading in healthy weight adults and adults with obesity. We collected three-dimensional gait analysis data on 10 adults with a normal body mass index and 10 adults with obesity during over ground walking in nine different conditions. In addition to preferred velocity and step length, we also conducted combinations of 15% increased and decreased velocity and step length. Peak tibiofemoral joint impulse and knee adduction angular impulse were reduced in the decreased step length conditions in both healthy weight adults (main effect) and those with obesity (interaction effect). Peak knee joint adduction moment was also reduced with decreased step length, and with decreased velocity in both groups. We conclude from these results that adopting shorter step lengths during daily activity and when walking for exercise can reduce mechanical stimuli associated with articular cartilage degenerative processes in adults with and without obesity. Thus, walking with reduced step length may benefit adults at risk for disability due to knee osteoarthritis. Adopting a shorter step length during daily walking activity may reduce knee joint loading and thus benefit those at risk for knee cartilage degeneration. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 9999:XX-XX, 2018. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Lai, Jian-Ping; Lai, Saien; Tuluc, Florin; Tansky, Morris F.; Kilpatrick, Laurie E.; Leeman, Susan E.; Douglas, Steven D.
2008-01-01
The neurokinin-1 receptor (NK1R) has two naturally occurring forms that differ in the length of the carboxyl terminus: a full-length receptor consisting of 407 aa and a truncated receptor consisting of 311 aa. We examined whether there are differential signaling properties attributable to the carboxyl terminus of this receptor by using stably transfected human embryonic kidney (HEK293) cell lines that express either full-length or truncated NK1R. Substance P (SP) specifically triggered intracellular calcium increase in HEK293 cells expressing full-length NK1R but had no effect in the cells expressing the truncated NK1R. In addition, in cells expressing full-length NK1R, SP activated NF-κB and IL-8 mRNA expression, but in cells expressing the truncated NK1R, SP did not activate NF-κB, and it decreased IL-8 mRNA expression. In cells expressing full-length NK1R, SP stimulated phosphorylation of PKCδ but inhibited phosphorylation of PKCδ in cells expressing truncated NK1R. There are also differences in the timing of SP-induced ERK activation in cells expressing the two different forms of the receptor. Full-length NK1R activation of ERK was rapid (peak within 1–2 min), whereas truncated NK1R-mediated activation was slower (peak at 20–30 min). Thus, the carboxyl terminus of NK1R is the structural basis for differences in the functional properties of the full-length and truncated NK1R. These differences may provide important information toward the design of new NK1R receptor antagonists. PMID:18713853
Influence of Sample Size of Polymer Materials on Aging Characteristics in the Salt Fog Test
NASA Astrophysics Data System (ADS)
Otsubo, Masahisa; Anami, Naoya; Yamashita, Seiji; Honda, Chikahisa; Takenouchi, Osamu; Hashimoto, Yousuke
Polymer insulators have been used in worldwide because of some superior properties; light weight, high mechanical strength, good hydrophobicity etc., as compared with porcelain insulators. In this paper, effect of sample size on the aging characteristics in the salt fog test is examined. Leakage current was measured by using 100 MHz AD board or 100 MHz digital oscilloscope and separated three components as conductive current, corona discharge current and dry band arc discharge current by using FFT and the current differential method newly proposed. Each component cumulative charge was estimated automatically by a personal computer. As the results, when the sample size increased under the same average applied electric field, the peak values of leakage current and each component current increased. Especially, the cumulative charges and the arc discharge length of dry band arc discharge increased remarkably with the increase of gap length.
Mask roughness induced LER: a rule of thumb -- paper
DOE Office of Scientific and Technical Information (OSTI.GOV)
McClinton, Brittany; Naulleau, Patrick
2010-03-12
Much work has already been done on how both the resist and line-edge roughness (LER) on the mask affect the final printed LER. What is poorly understood, however, is the extent to which system-level effects such as mask surface roughness, illumination conditions, and defocus couple to speckle at the image plane, and currently factor into LER limits. Here, we propose a 'rule-of-thumb' simplified solution that provides a fast and powerful method to obtain mask roughness induced LER. We present modeling data on an older generation mask with a roughness of 230 pm as well as the ultimate target roughness ofmore » 50 pm. Moreover, we consider feature sizes of 50 nm and 22 nm, and show that as a function of correlation length, the LER peaks at the condition that the correlation length is approximately equal to the resolution of the imaging optic.« less
Pseudorotational epitaxy of self-assembled octadecyltrichlorosilane monolayers on sapphire (0001)
Steinrück, H. -G.; Magerl, A.; Deutsch, M.; ...
2014-10-06
The structure of octadecyltrichlorosilane self-assembled monolayers (SAMs) on sapphire (0001) was studied by Å-resolution surface-specific x-ray scattering methods. The monolayer was found to consist of three sublayers where the outermost layer corresponds to vertically oriented, closely packed alkyl tails. Laterally, the monolayer is hexagonally packed and exhibits pseudorotational epitaxy to the sapphire, manifested by a broad scattering peak at zero relative azimuthal rotation, with long powderlike tails. The lattice mismatch of ~1% – 3% to the sapphire’s and the different length scale introduced by the lateral Si-O-Si bonding prohibit positional epitaxy. However, the substrate induces an intriguing increase in themore » crystalline coherence length of the SAM’s powderlike crystallites when rotationally aligned with the sapphire’s lattice. As a result, the increase correlates well with the rotational dependence of the separation of corresponding substrate-monolayer lattice sites.« less
Stride length: the impact on propulsion and bracing ground reaction force in overhand throwing.
Ramsey, Dan K; Crotin, Ryan L
2018-03-26
Propulsion and bracing ground reaction force (GRF) in overhand throwing are integral in propagating joint reaction kinetics and ball velocity, yet how stride length effects drive (hind) and stride (lead) leg GRF profiles remain unknown. Using a randomised crossover design, 19 pitchers (15 collegiate and 4 high school) were assigned to throw 2 simulated 80-pitch games at ±25% of their desired stride length. An integrated motion capture system with two force plates and radar gun tracked each throw. Vertical and anterior-posterior GRF was normalised then impulse was derived. Paired t-tests identified whether differences between conditions were significant. Late in single leg support, peak propulsion GRF was statistically greater for the drive leg with increased stride. Stride leg peak vertical GRF in braking occurred before acceleration with longer strides, but near ball release with shorter strides. Greater posterior shear GRF involving both legs demonstrated increased braking with longer strides. Conversely, decreased drive leg propulsion reduced both legs' braking effects with shorter strides. Results suggest an interconnection between normalised stride length and GRF application in propulsion and bracing. This work has shown stride length to be an important kinematic factor affecting the magnitude and timing of external forces acting upon the body.
Perinetti, Giuseppe; Contardo, Luca; Castaldo, Attilio; McNamara, James A; Franchi, Lorenzo
2016-07-01
To evaluate the capability of both cervical vertebral maturation (CVM) stages 3 and 4 (CS3-4 interval) and the peak in standing height to identify the mandibular growth spurt throughout diagnostic reliability analysis. A previous longitudinal data set derived from 24 untreated growing subjects (15 females and nine males,) detailed elsewhere were reanalyzed. Mandibular growth was defined as annual increments in Condylion (Co)-Gnathion (Gn) (total mandibular length) and Co-Gonion Intersection (Goi) (ramus height) and their arithmetic mean (mean mandibular growth [mMG]). Subsequently, individual annual increments in standing height, Co-Gn, Co-Goi, and mMG were arranged according to annual age intervals, with the first and last intervals defined as 7-8 years and 15-16 years, respectively. An analysis was performed to establish the diagnostic reliability of the CS3-4 interval or the peak in standing height in the identification of the maximum individual increments of each Co-Gn, Co-Goi, and mMG measurement at each annual age interval. CS3-4 and standing height peak show similar but variable accuracy across annual age intervals, registering values between 0.61 (standing height peak, Co-Gn) and 0.95 (standing height peak and CS3-4, mMG). Generally, satisfactory diagnostic reliability was seen when the mandibular growth spurt was identified on the basis of the Co-Goi and mMG increments. Both CVM interval CS3-4 and peak in standing height may be used in routine clinical practice to enhance efficiency of treatments requiring identification of the mandibular growth spurt.
NASA Astrophysics Data System (ADS)
Effenberg, F.; Feng, Y.; Schmitz, O.; Frerichs, H.; Bozhenkov, S. A.; Hölbe, H.; König, R.; Krychowiak, M.; Pedersen, T. Sunn; Reiter, D.; Stephey, L.; W7-X Team
2017-03-01
The results of a first systematic assessment of plasma edge transport processes for the limiter startup configuration at Wendelstein 7-X are presented. This includes an investigation of transport from intrinsic and externally injected impurities and their impact on the power balance and limiter heat fluxes. The fully 3D coupled plasma fluid and kinetic neutral transport Monte Carlo code EMC3-EIRENE is used. The analysis of the magnetic topology shows that the poloidally and toroidally localized limiters cause a 3D helical scrape-off layer (SOL) consisting of magnetic flux tubes of three different connection lengths L C. The transport in the helical SOL is governed by L C as topological scale length for the parallel plasma loss channel to the limiters. A clear modulation of the plasma pressure with L C is seen. The helical flux tube topology results in counter streaming sonic plasma flows. The heterogeneous SOL plasma structure yields an uneven limiter heat load distribution with localized peaking. Assuming spatially constant anomalous transport coefficients, increasing plasma density yields a reduction of the maximum peak heat loads from 12 MWm-2 to 7.5 MWm-2 and a broadening of the deposited heat fluxes. The impact of impurities on the limiter heat loads is studied by assuming intrinsic carbon impurities eroded from the limiter surfaces with a gross chemical sputtering yield of 2 % . The resulting radiative losses account for less than 10% of the input power in the power balance with marginal impact on the limiter heat loads. It is shown that a significant mitigation of peak heat loads, 40-50%, can be achieved with controlled impurity seeding with nitrogen and neon, which is a method of particular interest for the later island divertor phase.
NASA Astrophysics Data System (ADS)
Filipova, Valeriya; Lawrence, Deborah; Klempe, Harald
2018-02-01
Applying copula-based bivariate flood frequency analysis is advantageous because the results provide information on both the flood peak and volume. More data are, however, required for such an analysis, and it is often the case that only data series with a limited record length are available. To overcome this issue of limited record length, data regarding climatic and geomorphological properties can be used to complement statistical methods. In this paper, we present a study of 27 catchments located throughout Norway, in which we assess whether catchment properties, flood generation processes and flood regime have an effect on the correlation between flood peak and volume and, in turn, on the selection of copulas. To achieve this, the annual maximum flood events were first classified into events generated primarily by rainfall, snowmelt or a combination of these. The catchments were then classified into flood regime, depending on the predominant flood generation process producing the annual maximum flood events. A contingency table and Fisher's exact test were used to determine the factors that affect the selection of copulas in the study area. The results show that the two-parameter copulas BB1 and BB7 are more commonly selected in catchments with high steepness, high mean annual runoff and rainfall flood regime. These findings suggest that in these types of catchments, the dependence structure between flood peak and volume is more complex and cannot be modeled effectively using a one-parameter copula. The results illustrate that by relating copula types to flood regime and catchment properties, additional information can be supplied for selecting copulas in catchments with limited data.
[Remote system of natural gas leakage based on multi-wavelength characteristics spectrum analysis].
Li, Jing; Lu, Xu-Tao; Yang, Ze-Hui
2014-05-01
In order to be able to quickly, to a wide range of natural gas pipeline leakage monitoring, the remote detection system for concentration of methane gas was designed based on static Fourier transform interferometer. The system used infrared light, which the center wavelength was calibrated to absorption peaks of methane molecules, to irradiated tested area, and then got the interference fringes by converging collimation system and interference module. Finally, the system calculated the concentration-path-length product in tested area by multi-wavelength characteristics spectrum analysis algorithm, furthermore the inversion of the corresponding concentration of methane. By HITRAN spectrum database, Selected wavelength position of 1. 65 microm as the main characteristic absorption peaks, thereby using 1. 65 pm DFB laser as the light source. In order to improve the detection accuracy and stability without increasing the hardware configuration of the system, solved absorbance ratio by the auxiliary wave-length, and then get concentration-path-length product of measured gas by the method of the calculation proportion of multi-wavelength characteristics. The measurement error from external disturbance is caused by this innovative approach, and it is more similar to a differential measurement. It will eliminate errors in the process of solving the ratio of multi-wavelength characteristics, and can improve accuracy and stability of the system. The infrared absorption spectrum of methane is constant, the ratio of absorbance of any two wavelengths by methane is also constant. The error coefficients produced by the system is the same when it received the same external interference, so the measured noise of the system can be effectively reduced by the ratio method. Experimental tested standards methane gas tank with leaking rate constant. Using the tested data of PN1000 type portable methane detector as the standard data, and were compared to the tested data of the system, while tested distance of the system were 100, 200 and 500 m. Experimental results show that the methane concentration detected value was stable after a certain time leakage, the concentration-path-length product value of the system was stable. For detection distance of 100 m, the detection error of the concentration-path-length product was less than 1. 0%. With increasing distance from tested area, the detection error is increased correspondingly. When the distance was 500 m, the detection error was less than 4. 5%. In short, the detected error of the system is less than 5. 0% after the gas leakage stable, to meet the requirements of the field of natural gas leakage remote sensing.
Stretching single atom contacts at multiple subatomic step-length.
Wei, Yi-Min; Liang, Jing-Hong; Chen, Zhao-Bin; Zhou, Xiao-Shun; Mao, Bing-Wei; Oviedo, Oscar A; Leiva, Ezequiel P M
2013-08-14
This work describes jump-to-contact STM-break junction experiments leading to novel statistical distribution of last-step length associated with conductance of a single atom contact. Last-step length histograms are observed with up to five for Fe and three for Cu peaks at integral multiples close to 0.075 nm, a subatomic distance. A model is proposed in terms of gliding from a fcc hollow-site to a hcp hollow-site of adjacent atomic planes at 1/3 regular layer spacing along with tip stretching to account for the multiple subatomic step-length behavior.
NASA Technical Reports Server (NTRS)
Haynes, Jared; Kenny, Jeremy
2009-01-01
Lift-off acoustic environments for NASA's Ares I - Crew Launch Vehicle are predicted using the second source distribution methodology described in the NASA SP-8072. Three modifications made to the model include a shorter core length approximation, a core termination procedure upon plume deflection, and a new set of directivity indices measured from static test firings of the Reusable Solid Rocket Motor (RSRM). The modified sound pressure level predictions increased more than 5 dB overall, and the peak levels shifted two third-octave bands higher in frequency.
NASA Astrophysics Data System (ADS)
Roy, Debapriya; Biswas, Abhijit
2017-10-01
Using extensive numerical analysis we investigate effects of asymmetric sidewall spacers on various device parameters of 20-nm double gate MOSFETs associated with analog/RF applications. Our studies show that the device with underlap drain-side spacer length LED of 10 nm and source-side spacer length LES of 5 nm shows improvement in terms of the peak value of transconductance efficiency, voltage gain Av, unity-gain cut-off frequency fT and maximum frequency of oscillations fMAX by 8.6%, 51.7%, 5% and 10.3%, respectively compared to the symmetric 5 nm underlap spacer device with HfO2 spacer of dielectric constant k = 22. Additionally, a higher spacer dielectric constant increases the peak Av while decreasing both peak fT and fMAX. The detailed physical insight is exploited to design a cascode amplifier which yields an ultra-wide gain bandwidth of 2.48 THz at LED = 10 nm with a SiO2 spacer.
The distribution of galaxies within the 'Great Wall'
NASA Technical Reports Server (NTRS)
Ramella, Massimo; Geller, Margaret J.; Huchra, John P.
1992-01-01
The galaxy distribution within the 'Great Wall', the most striking feature in the first three 'slices' of the CfA redshift survey extension is examined. The Great Wall is extracted from the sample and is analyzed by counting galaxies in cells. The 'local' two-point correlation function within the Great Wall is computed and the local correlation length, is estimated 15/h Mpc, about 3 times larger than the correlation length for the entire sample. The redshift distribution of galaxies in the pencil-beam survey by Broadhurst et al. (1990) shows peaks separated about by large 'voids', at least to a redshift of about 0.3. The peaks might represent the intersections of their about 5/h Mpc pencil beams with structures similar to the Great Wall. Under this hypothesis, sampling of the Great Walls shows that l approximately 12/h Mpc is the minimum projected beam size required to detect all the 'walls' at redshifts between the peak of the selection function and the effective depth of the survey.
NASA Astrophysics Data System (ADS)
Carson, Robert Andrew
One of the primary aspects of the research and development work carried out at Benet Laboratories is the Soldier. Maintenance of their health in the field is the first priority while the second priority is the enhancement of their performance. Therefore, a new concept for a weapon system that targets these two priorities is highly desirable. This is the case with a new concept that can reduce the peak overpressure without the use of a muzzle device for a muzzle loaded cannon system. Such a novel concept was developed in this thesis through the application of propellant leak into the precursor region, i.e., when the projectile is still in the bore. A 3D hydrocode (ALE3D) was employed to predict the blast overpressure for the baseline and propellant leak configurations. However, a 3D hydrocode is computationally very expensive to predict peak overpressure in the far-field and an efficient method to predict peak overpressure in the far-field is of significance. Therefore, scaling laws for primary blast peak overpressure were also developed in this thesis. Initially, two propellant leak concepts were examined. A bulge leak method and a channel leak method, which were compared to the baseline configuration. The initial channel leak configuration (referred to as CLM-1) significantly reduced the exit pressure ratio during projectile ejection, and thereby, resulted in a weaker blast. This in-turn substantially attenuated the peak overpressure to the rear of the muzzle without the aid of a muzzle device while having a marginal loss in the projectile exit velocity. For CLM-1, at one monitored location with the largest peak overpressure, a reduction of about 38% in peak overpressure was observed as compared to the baseline case. In order to compare different leak configurations, a performance metric was defined by comparing the ratio of peak overpressure and projectile exit velocity for a leak configuration to that for the baseline configuration. This metric was referred to as the Figure of Merit (FoM) and defined for any probe location. An average FoM was also defined based on the average of local FoM over different locations/probes. The greater the FoM is above zero, the better the configuration. The average FoM for the CLM-1 configuration was 0.221. In addition to FoM, shock structure and strength were also analyzed for the bulge and channel configurations at both the precursor and blast stages. With the success of the CLM-1 configuration, we then performed a parametric study of the channel leak geometry and examined the effect of different geometric parameters on peak overpressure attenuation. The idea was to further improve the performance of the channel leak method. We divided our parametric study into five groups (i.e., A through E), referred to as CLM-A through CLM-E configurations. The focus in these five groups was on geometric parameters that were expected to be the most influential or relevant. Three relevant geometric parameters were considered in this work. In groups A and B, we focused on channel leak volume. Group C analyzed the effect of channel length while groups D and E investigated the effect of aspect ratio. The five groups were ordered in this way because we anticipated the total leak volume to be the most influential parameter, then the channel length which was followed by the aspect ratio. The total leak volume of 7.5% resulted in a relatively high average FoM. On the other hand, the use of channels with a shorter length was found to be detrimental while a lower value of aspect ratio was beneficial. Three leak configurations of CLM-A1, CLM-E1 and CLM-E2 provided excellent peak overpressure attenuation (i.e., above 45% and up to 63%). Each led to an average FoM above 0.5 while CLM-E configurations resulted in lower local FoM for probes near the muzzle and higher FoM for probes farther from the muzzle, and thus, a higher variation of FoM over the probes. The average FoM based on the far-field probes was about 0.575 and 0.560 for CLM-E1 and CLM-E2, respectively, and 0.520 for CLM-A1. Blast structure and strength were also analyzed for these three configurations. In the last part of this thesis, we focused on the baseline and CLM-A1 configurations in order to develop scaling laws for the primary blast peak overpressure. Two different power-law scaling techniques were considered. In the first power-law, scaling parameters were defined from the muzzle center. The second power-law scaling was defined based on the blast center. The muzzle center based power-law has been used in the past while the blast center based power-law is a newly developed scaling law in this thesis. For the baseline configuration, both scaling laws performed well and for many locations absolute difference was below 10%. For the CLM-A1 configuration, blast center based power-law predictions were better than those from the muzzle center based power-law and showed a better overall correlation with the ALE3D predictions.
Ecology of a Maryland population of black rat snakes (Elaphe o. obsoleta)
Stickel, L.F.; Stickel, W.H.; Schmid, F.C.
1980-01-01
Behavior, growth and age of black rat snakes under natural conditions were investigated by mark-recapture methods at the Patuxent Wildlife Research Center for 22 years (1942-1963), with limited observations for 13 more years (1964-1976). Over the 35-year period, 330 snakes were recorded a total of 704 times. Individual home ranges remained stable for many years; male ranges averaged at least 600 m in diam and female ranges at least 500 m, each including a diversity of habitats, evidenced also in records of foods. Population density was low, probably less than 0.5 snake/ha. Peak activity of both sexes was in May and June, with a secondary peak in September. Large trees in the midst of open areas appeared to serve a significant functional role in the behavioral life pattern of the snake population. Male combat was observed three times in the field. Male snakes grew more rapidly than females, attained larger sizes and lived longer. Some individuals of both sexes probably lived 20 years or more. Weight-length relationships changed as the snakes grew and developed heavier bodies in proportion to length. Growth apparently continued throughout life. Some individuals, however, both male and female, stopped growing for periods of I or 2 years and then resumed, a condition probably related to poor health, suggested by skin ailments.
A PDMS microfiber Mach-Zehnder interferometer and determination of nanometer displacements
NASA Astrophysics Data System (ADS)
Martincek, Ivan; Kacik, Daniel
2018-01-01
A polydimethylsiloxane (PDMS) microfiber Mach-Zehnder interferometer (MZI), integrated between single-mode optical fibers (SMFs), is proposed and demonstrated experimentally. One arm of the interferometer consists of a microfiber of diameter 7 μm and length 270 μm; the second is an air arm. Due to the good elastic properties of PDMS microfiber, the length of the air arm of MZI can be changed by changing the distance between SMFs. The change in length of the air arm results in a change in the transmission characteristics of the MZI; thus, the relative displacement can be measured in the range 10-250 nm. By measuring the peak-to-peak amplitude of the difference in transmission powers (in dB), the smallest displacement by prepared MZI was determined as being on the order of a few nm for a ratio of intensities of 0.135. For a higher ratio of intensities of transmission functions, the smallest displacement could be determined on the order of subnanometers.
Correlation of atomic packing with the boson peak in amorphous alloys
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, W. M.; Key Laboratory of Magnetic Materials and Devices, Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201; School of Materials Science and Engineering, Southeast University, Nanjing 211189
2014-09-28
Boson peaks (BP) have been observed from phonon specific heats in 10 studied amorphous alloys. Two Einstein-type vibration modes were proposed in this work and all data can be fitted well. By measuring and analyzing local atomic structures of studied amorphous alloys and 56 reported amorphous alloys, it is found that (a) the BP originates from local harmonic vibration modes associated with the lengths of short-range order (SRO) and medium-range order (MRO) in amorphous alloys, and (b) the atomic packing in amorphous alloys follows a universal scaling law, i.e., the ratios of SRO and MRO lengths to solvent atomic diametermore » are 3 and 7, respectively, which exact match with length ratios of BP vibration frequencies to Debye frequency for the studied amorphous alloys. This finding provides a new perspective for atomic packing in amorphous materials, and has significant implications for quantitative description of the local atomic orders and understanding the structure-property relationship.« less
[An automatic peak detection method for LIBS spectrum based on continuous wavelet transform].
Chen, Peng-Fei; Tian, Di; Qiao, Shu-Jun; Yang, Guang
2014-07-01
Spectrum peak detection in the laser-induced breakdown spectroscopy (LIBS) is an essential step, but the presence of background and noise seriously disturb the accuracy of peak position. The present paper proposed a method applied to automatic peak detection for LIBS spectrum in order to enhance the ability of overlapping peaks searching and adaptivity. We introduced the ridge peak detection method based on continuous wavelet transform to LIBS, and discussed the choice of the mother wavelet and optimized the scale factor and the shift factor. This method also improved the ridge peak detection method with a correcting ridge method. The experimental results show that compared with other peak detection methods (the direct comparison method, derivative method and ridge peak search method), our method had a significant advantage on the ability to distinguish overlapping peaks and the precision of peak detection, and could be be applied to data processing in LIBS.
El-Sherbiny, Mohsen M.; Al-Aidaroos, Ali M.
2014-01-01
Abstract The calanoid copepod, Acartia bispinosa Carl, 1907, is reported for the first time in the Red Sea, where it is found to be an important copepod in the mesozooplankton community structure of the Sharm El-Maya Bay. Female and male are fully redescribed and illustrated of as the mouthparts of this species have never previously been described and figured. Acartia bispinosa was collected in the plankton samples throughout the year and showed two peaks of abundance, a pronounced one in April (4234 individuals m-3), and second smaller peak during November (1784 individuals m-3). The average total length of females varied between 1.32 and 1.53 mm at the end of June and January respectively. For males, the average total length fluctuated between 1.07 and 1.16 mm at end of June and March respectively. Temperature showed an inverse relationship with the body length (P > 0.001) and seemed to be one of the prime factors affecting the body length of both sexes. PMID:25349502
Waltemeyer, Scott D.
2008-01-01
Estimates of the magnitude and frequency of peak discharges are necessary for the reliable design of bridges, culverts, and open-channel hydraulic analysis, and for flood-hazard mapping in New Mexico and surrounding areas. The U.S. Geological Survey, in cooperation with the New Mexico Department of Transportation, updated estimates of peak-discharge magnitude for gaging stations in the region and updated regional equations for estimation of peak discharge and frequency at ungaged sites. Equations were developed for estimating the magnitude of peak discharges for recurrence intervals of 2, 5, 10, 25, 50, 100, and 500 years at ungaged sites by use of data collected through 2004 for 293 gaging stations on unregulated streams that have 10 or more years of record. Peak discharges for selected recurrence intervals were determined at gaging stations by fitting observed data to a log-Pearson Type III distribution with adjustments for a low-discharge threshold and a zero skew coefficient. A low-discharge threshold was applied to frequency analysis of 140 of the 293 gaging stations. This application provides an improved fit of the log-Pearson Type III frequency distribution. Use of the low-discharge threshold generally eliminated the peak discharge by having a recurrence interval of less than 1.4 years in the probability-density function. Within each of the nine regions, logarithms of the maximum peak discharges for selected recurrence intervals were related to logarithms of basin and climatic characteristics by using stepwise ordinary least-squares regression techniques for exploratory data analysis. Generalized least-squares regression techniques, an improved regression procedure that accounts for time and spatial sampling errors, then were applied to the same data used in the ordinary least-squares regression analyses. The average standard error of prediction, which includes average sampling error and average standard error of regression, ranged from 38 to 93 percent (mean value is 62, and median value is 59) for the 100-year flood. The 1996 investigation standard error of prediction for the flood regions ranged from 41 to 96 percent (mean value is 67, and median value is 68) for the 100-year flood that was analyzed by using generalized least-squares regression analysis. Overall, the equations based on generalized least-squares regression techniques are more reliable than those in the 1996 report because of the increased length of record and improved geographic information system (GIS) method to determine basin and climatic characteristics. Flood-frequency estimates can be made for ungaged sites upstream or downstream from gaging stations by using a method that transfers flood-frequency data at the gaging station to the ungaged site by using a drainage-area ratio adjustment equation. The peak discharge for a given recurrence interval at the gaging station, drainage-area ratio, and the drainage-area exponent from the regional regression equation of the respective region is used to transfer the peak discharge for the recurrence interval to the ungaged site. Maximum observed peak discharge as related to drainage area was determined for New Mexico. Extreme events are commonly used in the design and appraisal of bridge crossings and other structures. Bridge-scour evaluations are commonly made by using the 500-year peak discharge for these appraisals. Peak-discharge data collected at 293 gaging stations and 367 miscellaneous sites were used to develop a maximum peak-discharge relation as an alternative method of estimating peak discharge of an extreme event such as a maximum probable flood.
Roman-Gusetu, Georgiana; Waldron, Karen C; Rochefort, Dominic
2009-11-20
Microencapsulation is used here as a new technique to immobilize enzymes in a microreactor coupled off-line to capillary electrophoresis (CE), allowing the determination of enzymatic reaction products. The redox enzyme laccase was encapsulated using the method of interfacial cross-linking of poly(ethyleneimine) (PEI). The 50 microm diameter capsules were slurry packed from a suspension into a capillary-sized reactor made easily and quickly from a short length of 530 microm diameter fused-silica tubing. The volume of the bed of laccase microcapsules in the microreactor was in the order of 1.1 microL through which 50 microL of the substrate o-phenylenediamine (OPD) was flowed. The oxidation product 2,3-diaminophenazine (DAP) and the remaining OPD were quantified by CE in a pH 2.5 phosphate buffer. Peak migration time reproducibility was in the order of 0.4% RSD and peak area reproducibility was less than 1.7% RSD within the same day. Using the OPD peak area calibration curve, a conversion efficiency of 48% was achieved for a 2-min oxidation reaction in the microreactor.
Acetanilide mediated reversible assembly and disassembly of Au nanoparticles.
Murugadoss, A; Kar, Manoranjan; Chattopadhyay, Arun
2008-08-01
Herein we report the generation of Au nanoparticles (NPs) by sparingly soluble acetanilide in water. We also report the formation of linear chain-like superstructures of self-assembled Au NPs, in the presence of excess acetanilide. This was achieved in two different ways. In the first method, acetanilide was added, with increasing concentration, into aqueous HAuCl(4) to produce Au NPs as well as for the formation of assembly, which varied according to the concentration of acetanilide. The other route involved formation of spherical Au NPs at the lowest concentration of acetanilide, which was followed by the formation of assembly of various lengths upon further addition of variable amount of acetanilide. The assemblies were stable in aqueous solution for days with characteristic UV-vis absorption spectra consisting of two peaks. While the wavelength of the first peak remained the same, the position of the second peak changed to longer wavelength with increasing acetanilide concentration. Interestingly, the linear chain-like arrays could be broken into individual particles by first dilution of the solution concentration followed by treatment with ultrasonic waves. The individual Au NPs again formed linear chain-like arrays upon addition of excess acetanilide.
A double expansion method for the frequency response of finite-length beams with periodic parameters
NASA Astrophysics Data System (ADS)
Ying, Z. G.; Ni, Y. Q.
2017-03-01
A double expansion method for the frequency response of finite-length beams with periodic distribution parameters is proposed. The vibration response of the beam with spatial periodic parameters under harmonic excitations is studied. The frequency response of the periodic beam is the function of parametric period and then can be expressed by the series with the product of periodic and non-periodic functions. The procedure of the double expansion method includes the following two main steps: first, the frequency response function and periodic parameters are expanded by using identical periodic functions based on the extension of the Floquet-Bloch theorem, and the period-parametric differential equation for the frequency response is converted into a series of linear differential equations with constant coefficients; second, the solutions to the linear differential equations are expanded by using modal functions which satisfy the boundary conditions, and the linear differential equations are converted into algebraic equations according to the Galerkin method. The expansion coefficients are obtained by solving the algebraic equations and then the frequency response function is finally determined. The proposed double expansion method can uncouple the effects of the periodic expansion and modal expansion so that the expansion terms are determined respectively. The modal number considered in the second expansion can be reduced remarkably in comparison with the direct expansion method. The proposed double expansion method can be extended and applied to the other structures with periodic distribution parameters for dynamics analysis. Numerical results on the frequency response of the finite-length periodic beam with various parametric wave numbers and wave amplitude ratios are given to illustrate the effective application of the proposed method and the new frequency response characteristics, including the parameter-excited modal resonance, doubling-peak frequency response and remarkable reduction of the maximum frequency response for certain parametric wave number and wave amplitude. The results have the potential application to structural vibration control.
Sherwood, J.M.
1986-01-01
Methods are presented for estimating peak discharges, flood volumes and hydrograph shapes of small (less than 5 sq mi) urban streams in Ohio. Examples of how to use the various regression equations and estimating techniques also are presented. Multiple-regression equations were developed for estimating peak discharges having recurrence intervals of 2, 5, 10, 25, 50, and 100 years. The significant independent variables affecting peak discharge are drainage area, main-channel slope, average basin-elevation index, and basin-development factor. Standard errors of regression and prediction for the peak discharge equations range from +/-37% to +/-41%. An equation also was developed to estimate the flood volume of a given peak discharge. Peak discharge, drainage area, main-channel slope, and basin-development factor were found to be the significant independent variables affecting flood volumes for given peak discharges. The standard error of regression for the volume equation is +/-52%. A technique is described for estimating the shape of a runoff hydrograph by applying a specific peak discharge and the estimated lagtime to a dimensionless hydrograph. An equation for estimating the lagtime of a basin was developed. Two variables--main-channel length divided by the square root of the main-channel slope and basin-development factor--have a significant effect on basin lagtime. The standard error of regression for the lagtime equation is +/-48%. The data base for the study was established by collecting rainfall-runoff data at 30 basins distributed throughout several metropolitan areas of Ohio. Five to eight years of data were collected at a 5-min record interval. The USGS rainfall-runoff model A634 was calibrated for each site. The calibrated models were used in conjunction with long-term rainfall records to generate a long-term streamflow record for each site. Each annual peak-discharge record was fitted to a Log-Pearson Type III frequency curve. Multiple-regression techniques were then used to analyze the peak discharge data as a function of the basin characteristics of the 30 sites. (Author 's abstract)
Gritti, Fabrice; Guiochon, Georges
2011-08-05
The corrected heights equivalent to a theoretical plate (HETP) of three 4.6mm I.D. monolithic Onyx-C(18) columns (Onyx, Phenomenex, Torrance, CA) of different lengths (2.5, 5, and 10 cm) are reported for retained (toluene, naphthalene) and non-retained (uracil, caffeine) small molecules. The moments of the peak profiles were measured according to the accurate numerical integration method. Correction for the extra-column contributions was systematically applied. The peak parking method was used in order to measure the bulk diffusion coefficients of the sample molecules, their longitudinal diffusion terms, and the eddy diffusion term of the three monolithic columns. The experimental results demonstrate that the maximum efficiency was 60,000 plates/m for retained compounds. The column length has a large impact on the plate height of non-retained species. These observations were unambiguously explained by a large trans-column eddy diffusion term in the van Deemter HETP equation. This large trans-rod eddy diffusion term is due to the combination of a large trans-rod velocity bias (≃3%), a small radial dispersion coefficient in silica monolithic columns, and a poorly designed distribution and collection of the sample streamlets at the inlet and outlet of the monolithic rod. Improving the performance of large I.D. monolithic columns will require (1) a detailed knowledge of the actual flow distribution across and along these monolithic rod and (2) the design of appropriate inlet and outlet distributors designed to minimize the nefarious impact of the radial flow heterogeneity on band broadening. Copyright © 2011 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nepal, Neeraj; Anderson, Virginia R.; Johnson, Scooter D.
The temporal evolution of high quality indium nitride (InN) growth by plasma-assisted atomic layer epitaxy (ALEp) on a-plane sapphire at 200 and 248 °C was probed by synchrotron x-ray methods. The growth was carried out in a thin film growth facility installed at beamline X21 of the National Synchrotron Light Source at Brookhaven National Laboratory and at beamline G3 of the Cornell High Energy Synchrotron Source, Cornell University. Measurements of grazing incidence small angle x-ray scattering (GISAXS) during the initial cycles of growth revealed a broadening and scattering near the diffuse specular rod and the development of scattering intensities duemore » to half unit cell thick nucleation islands in the Yoneda wing with correlation length scale of 7.1 and 8.2 nm, at growth temperatures (Tg) of 200 and 248 °C, respectively. At about 1.1 nm (two unit cells) of growth thickness nucleation islands coarsen, grow, and the intensity of correlated scattering peak increased at the correlation length scale of 8.0 and 8.7 nm for Tg = 200 and 248 °C, respectively. The correlated peaks at both growth temperatures can be fitted with a single peak Lorentzian function, which support single mode growth. Post-growth in situ x-ray reflectivity measurements indicate a growth rate of ~0.36 Å/cycle consistent with the growth rate previously reported for self-limited InN growth in a commercial ALEp reactor. Consistent with the in situ GISAXS study, ex situ atomic force microscopy power spectral density measurements also indicate single mode growth. Electrical characterization of the resulting film revealed an electron mobility of 50 cm2/V s for a 5.6 nm thick InN film on a-plane sapphire, which is higher than the previously reported mobility of much thicker InN films grown at higher temperature by molecular beam epitaxy directly on sapphire. These early results indicated that in situ synchrotron x-ray study of the epitaxial growth kinetics of InN films is a very powerful method to understand nucleation and growth mechanisms of ALEp to enable improvement in material quality and broaden its application.« less
NASA Astrophysics Data System (ADS)
Tobiasson, John Robert
2017-07-01
There is a growing need for the clean generation of electricity in the world, and increased efficiency is one way to achieve cleaner generation. Increased efficiency may be achieved through an improved understanding of the heat flux of participating media in combustion environments. Real-time in-situ optical measurements of gas temperature and concentrations in combustion environments is needed. Optical methods do not disturb the flow characteristics and are not subject to the temperature limitation of current methods. Simpler, less-costly optical measurements than current methods would increase the ability to apply them in more circumstances. This work explores the ability to simultaneously measure gas temperature and H2O concentration via integrated spectral intensity ratios in regions where H2O is the dominant participating gas. This work considered combustion flows with and without fuel and soot particles, and is an extension of work previously performed by Ellis et al. [1]. Five different combustion regimes were used to investigate the robustness of the infrared intensity integral method first presented by Ellis et al. [1]. These included Post-Flame Natural Gas (PFNG), Post-Flame Medium Wood (PFMW), Post-Flame Fine Wood (PFFW), In-Flame Natural Gas (IFNG), and In-Flame Fine Wood (IFFW). Optical spectra were collected as a function of path length for each regime. Methods for processing the spectra to obtain gas temperature, gas concentration, broadband temperature, and broadband emissivity were developed. A one-dimensional spectral intensity model that allowed for specular reflection, and investigated differences between measured and modeled spectral intensities was created. It was concluded that excellent agreement (within 2.5%) was achieved between optical and suction pyrometer gas temperatures as long as 1) the optical probe and cold target used were well-aligned 2) the path length was greater than 0.3 m and 3) the intensity from broadband emitters within the path was smaller than the gas intensity. Shorter path lengths between 0.15 - 0.3 m produced reasonable temperatures with 7% error while path lengths of 0.05 m or less were as much as 15% in error or the signal would not effectively process. Water vapor concentration was less accurate being at best within 20% (relative) of expected values. The accurate determination of concentration requires first an accurate temperature concentration as well low broadband participation. Some optical concentrations were in error as much as 85%. The 1-D model was compared to the measurement and it was found that the model peaks were sharper and shifted 0.167 cm-1 compared to the measured data. The reason for the shift can be attributed to the uncertainty of the reference laser frequency used in the FTIR. No conclusion was found for the cause of the sharper peaks in the model. The integrated area of bands used to find temperature and concentration matched well between the model and measured spectrum being typically within 3%.
Mahrooghy, Majid; Yarahmadian, Shantia; Menon, Vineetha; Rezania, Vahid; Tuszynski, Jack A
2015-10-01
Microtubules (MTs) are intra-cellular cylindrical protein filaments. They exhibit a unique phenomenon of stochastic growth and shrinkage, called dynamic instability. In this paper, we introduce a theoretical framework for applying Compressive Sensing (CS) to the sampled data of the microtubule length in the process of dynamic instability. To reduce data density and reconstruct the original signal with relatively low sampling rates, we have applied CS to experimental MT lament length time series modeled as a Dichotomous Markov Noise (DMN). The results show that using CS along with the wavelet transform significantly reduces the recovery errors comparing in the absence of wavelet transform, especially in the low and the medium sampling rates. In a sampling rate ranging from 0.2 to 0.5, the Root-Mean-Squared Error (RMSE) decreases by approximately 3 times and between 0.5 and 1, RMSE is small. We also apply a peak detection technique to the wavelet coefficients to detect and closely approximate the growth and shrinkage of MTs for computing the essential dynamic instability parameters, i.e., transition frequencies and specially growth and shrinkage rates. The results show that using compressed sensing along with the peak detection technique and wavelet transform in sampling rates reduces the recovery errors for the parameters. Copyright © 2015 Elsevier Ltd. All rights reserved.
Mueller, MJ; Strube, MJ; Allen, BT
1997-04-01
INTRODUCTION:: Patients with diabetes (DM) and transmetatarsal amputation (TMA) are at high risk for skin breakdown from excessive peak plantar pressures (PPP). The primary purpose of this study was to determine how footwear (full length shoe or short shoe), a total contact insert, a rigid-rocker bottom (RRB) sole, and an ankle-foot-orthosis (AFO) affect PPP on the distal residuum and contralateral extremity of patients with DM and TMA. A secondary purpose was to monitor various functional measures during use of the footwear. METHODS:: Thirty patients with DM and TMA participated (mean age 62+/-4 years). The mean duration of DM was 19.9+/-10.1 years, and the mean time since TMA was 27.4+/-28.1 months. The following footwear was provided after a check-out from an orthotist and physical therapist (PT); 1) Full length shoe (ie shoe length prior to surgery), with a toe filler, 2) full length shoe, total contact insert, and an AFO, 2) full length shoe, total contact insert, and an AFO, 3) full length shoe, total contact insert, and a RRB sole, 4) full length shoe, total contact insert, RRB sole, and an AFO, 5) short shoe (ie length of residuum), total contact insert, and RRB, 6) short shoe, total contact insert, AFO, and RRB sole. In-shoe PPP during walking at the distal residuum and forefoot of the contralateral extremity were measured using the F-Scan System with established reliability under similar conditions (Generilizability coefficient =.75). Each measurement occurred after a one month adjustment period. Data were analyzed using a univariate repeated measuresANOVA. Individual contrasts were used for post-hoc analysis on those variables showing a significant overall F value (p<.05). RESULTS:: Compared to a regular shoe with a toe-filler, all conditions except the short shoe (#5), resulted in lower PPP on the distal residuum (p<.05). Condition 3, the full length shoe, total contact insert, and RRB resulted in lower pressures on the distal residuum and forefoot of the contralateral extremity compared to a regular shoe and toe-filler, and had few functional complaints as identified by the patient, orthotist or PT (3/27). Footwear using an AFO (Conditions 2,4,6) showed reduced PPP on the residuum, but most patients (16/29) had functional complaints. The short shoe (condition 5) had the fewest[Table: see text] functional complaints (2/26), but did not significantly reduce PPP and had the highest cosmetic refusal rate (5/26). DISCUSSION AND CONCLUSIONS:: Although there are individual patient characteristics which warrant other prescriptions, based on the results of this study, we recommend the full length shoe, total contact insert, and RRB sole for most patients with DM and TMA to reduce PPP. A reduction in PPP should help to lower the high risk of skin breakdown in this patient population.
NASA Astrophysics Data System (ADS)
Lee, Sung Hyun; Sunaguchi, Naoki; Hirano, Yoshiyuki; Kano, Yosuke; Liu, Chang; Torikoshi, Masami; Ohno, Tatsuya; Nakano, Takashi; Kanai, Tatsuaki
2018-02-01
In this study, we investigate the performance of the Gunma University Heavy Ion Medical Center’s ion computed tomography (CT) system, which measures the residual range of a carbon-ion beam using a fluoroscopy screen, a charge-coupled-device camera, and a moving wedge absorber and collects CT reconstruction images from each projection angle. Each 2D image was obtained by changing the polymethyl methacrylate (PMMA) thickness, such that all images for one projection could be expressed as the depth distribution in PMMA. The residual range as a function of PMMA depth was related to the range in water through a calibration factor, which was determined by comparing the PMMA-equivalent thickness measured by the ion CT system to the water-equivalent thickness measured by a water column. Aluminium, graphite, PMMA, and five biological phantoms were placed in a sample holder, and the residual range for each was quantified simultaneously. A novel method of CT reconstruction to correct for the angular deflection of incident carbon ions in the heterogeneous region utilising the Bragg peak reduction (BPR) is also introduced in this paper, and its performance is compared with other methods present in the literature such as the decomposition and differential methods. Stopping power ratio values derived with the BPR method from carbon-ion CT images matched closely with the true water-equivalent length values obtained from the validation slab experiment.
Kapoor, Utkarsh; Shah, Jindal K
2018-01-11
Segregation of polar and nonpolar domains in ionic liquids for which either the cation or anion is responsible for inducing nonpolar domains is well understood. On the other hand, information regarding the nanoscale heterogeneities originating due to the presence of nonpolar content on both the ions is rudimentary at this point. The present contribution is aimed at addressing this question and focuses on a molecular dynamics simulation study to probe nanoscale structural and aggregation features of the 1-n-alkyl-3-methylimidazolium [C n mim] octylsulfate [C 8 SO 4 ] ionic liquid homologous series (n = 2, 4, 6, 8, 10, and 12). The objective of this work is to determine the effect of increasing alkyl chain length in the cation on nonpolar domain formation, especially when the alkyl chain lengths from both the ions participate in defining such domains. The results indicate that all the ionic liquids form nonpolar domains, morphology of which gradually changes from globular, sponge-like to layer-like structure with increase in the cationic alkyl chain length. The length of the nonpolar domains calculated from the total structure factor for [C 10 mim][C 8 SO 4 ] is considerably higher than that reported for other imidazolium-based ionic liquid containing smaller anions. The structure factor for [C 12 mim][C 8 SO 4 ] ionic liquid contains multiple intermediate peaks separating the charge alternation peak and pre-peak, which points to nonpolar domains of varying lengths, an observation that remains to be validated. Analysis of the heterogeneous order parameters and orientational correlation functions of the alkyl chains further suggests an increase in the spatial heterogeneity and long-range order along the homologous series. The origin of rich diversity of structures obtained by introducing nonpolar content on both the ions is discussed.
Parrett, Charles; Veilleux, Andrea; Stedinger, J.R.; Barth, N.A.; Knifong, Donna L.; Ferris, J.C.
2011-01-01
Improved flood-frequency information is important throughout California in general and in the Sacramento-San Joaquin River Basin in particular, because of an extensive network of flood-control levees and the risk of catastrophic flooding. A key first step in updating flood-frequency information is determining regional skew. A Bayesian generalized least squares (GLS) regression method was used to derive a regional-skew model based on annual peak-discharge data for 158 long-term (30 or more years of record) stations throughout most of California. The desert areas in southeastern California had too few long-term stations to reliably determine regional skew for that hydrologically distinct region; therefore, the desert areas were excluded from the regional skew analysis for California. Of the 158 long-term stations used to determine regional skew, 145 have minimally regulated annual-peak discharges, and 13 stations are dam sites for which unregulated peak discharges were estimated from unregulated daily maximum discharge data furnished by the U.S. Army Corp of Engineers. Station skew was determined by using an expected moments algorithm (EMA) program for fitting the Pearson Type 3 flood-frequency distribution to the logarithms of annual peak-discharge data. The Bayesian GLS regression method previously developed was modified because of the large cross correlations among concurrent recorded peak discharges in California and the use of censored data and historical flood information with the new expected moments algorithm. In particular, to properly account for these cross-correlation problems and develop a suitable regression model and regression diagnostics, a combination of Bayesian weighted least squares and generalized least squares regression was adopted. This new methodology identified a nonlinear function relating regional skew to mean basin elevation. The regional skew values ranged from -0.62 for a mean basin elevation of zero to 0.61 for a mean basin elevation of 11,000 feet. This relation between skew and elevation reflects the interaction of snow with rain, which increases with increased elevation. The equivalent record length for the new regional skew ranges from 52 to 65 years of record, depending upon mean basin elevation. The old regional skew map in Bulletin 17B, published by the Hydrology Subcommittee of the Interagency Advisory Committee on Water Data (1982), reported an equivalent record length of only 17 years. The newly developed regional skew relation for California was used to update flood frequency for the 158 sites used in the regional skew analysis as well as 206 selected sites in the Sacramento-San Joaquin River Basin. For these sites, annual-peak discharges having recurrence intervals of 2, 5, 10, 25, 50, 100, 200, and 500 years were determined on the basis of data through water year 2006. The expected moments algorithm was used for determining the magnitude and frequency of floods at gaged sites by using regional skew values and using the basic approach outlined in Bulletin
Optimal periodic binary codes of lengths 28 to 64
NASA Technical Reports Server (NTRS)
Tyler, S.; Keston, R.
1980-01-01
Results from computer searches performed to find repeated binary phase coded waveforms with optimal periodic autocorrelation functions are discussed. The best results for lengths 28 to 64 are given. The code features of major concern are where (1) the peak sidelobe in the autocorrelation function is small and (2) the sum of the squares of the sidelobes in the autocorrelation function is small.
DeGiuli, Eric; Laversanne-Finot, Adrien; Düring, Gustavo; Lerner, Edan; Wyart, Matthieu
2014-08-14
Connectedness and applied stress strongly affect elasticity in solids. In various amorphous materials, mechanical stability can be lost either by reducing connectedness or by increasing pressure. We present an effective medium theory of elasticity that extends previous approaches by incorporating the effect of compression, of amplitude e, allowing one to describe quantitative features of sound propagation, transport, the boson peak, and elastic moduli near the elastic instability occurring at a compression ec. The theory disentangles several frequencies characterizing the vibrational spectrum: the onset frequency where strongly-scattered modes appear in the vibrational spectrum, the pressure-independent frequency ω* where the density of states displays a plateau, the boson peak frequency ωBP found to scale as , and the Ioffe-Regel frequency ωIR where scattering length and wavelength become equal. We predict that sound attenuation crosses over from ω(4) to ω(2) behaviour at ω0, consistent with observations in glasses. We predict that a frequency-dependent length scale ls(ω) and speed of sound ν(ω) characterize vibrational modes, and could be extracted from scattering data. One key result is the prediction of a flat diffusivity above ω0, in agreement with previously unexplained observations. We find that the shear modulus does not vanish at the elastic instability, but drops by a factor of 2. We check our predictions in packings of soft particles and study the case of covalent networks and silica, for which we predict ωIR ≈ ωBP. Overall, our approach unifies sound attenuation, transport and length scales entering elasticity in a single framework where disorder is not the main parameter controlling the boson peak, in agreement with observations. This framework leads to a phase diagram where various glasses can be placed, connecting microscopic structure to vibrational properties.
Fedosov, Sergey N; Fedosova, Natalya U; Berglund, Lars; Moestrup, Søren K; Nexø, Ebba; Petersen, Torben E
2004-11-30
Human intrinsic factor (IF) was purified from the recombinant plant Arabidopsis thaliana by affinity chromatography. Cobalamin (Cbl) saturated protein was separated by gel filtration into peaks I and II, which contained according to SDS electrophoresis the 50 kDa full-length protein IF(50) and a mixture of two fragments, respectively. Two components of peak II were identified as the 30 kDa N-terminal peptide IF(30) and the 20 kDa C-terminal glycopeptide IF(20). Measurements of M(w) under the nondenaturing conditions were conducted by static light scattering. They revealed 100 kDa IF dimers in peak I, whereas 50 kDa cleaved monomers were found in peak II. The protein devoid of Cbl dissociated to the elementary units incapable of association in the absence of Cbl. The individual proteolytic fragments bound Cbl at high concentration of the ligand; however, neither IF(30).Cbl nor IF(20).Cbl oligomerized. A mixture of two fragments IF(30) + IF(20) and Cbl produced a firm complex, IF(30+20).Cbl, which could not associate to dimers. In contrast to IF(30+20).Cbl, the saturated full-length monomers IF(50).Cbl dimerized with K(d) approximately 1 microM. We suggest a two-domain organization of the full-length protein, where two distant units, IF(30) and IF(20), can be assembled only by Cbl. They are connected by a protease-sensitive link, whose native structure is likely to be important for dimerization. However, linkage between two domains is not compulsory for Cbl binding. Advantages of the two-domain structure of IF are discussed.
Gap prepulse inhibition of the auditory late response in healthy subjects.
Ku, Yunseo; Ahn, Joong Woo; Kwon, Chiheon; Suh, Myung-Whan; Lee, Jun Ho; Oh, Seung Ha; Kim, Hee Chan
2015-11-01
The gap-startle paradigm has been used as a behavioral method for tinnitus screening in animal studies. This study aimed to investigate gap prepulse inhibition (GPI) of the auditory late response (ALR) as the objective response of the gap-intense sound paradigm in humans. ALRs were recorded in response to gap-intense and no-gap-intense sound stimuli in 27 healthy subjects. The amplitudes of the baseline-to-peak (N1, P2, and N2) and the peak-to-peak (N1P2 and P2N2) were compared between two averaged ALRs. The variations in the inhibition ratios of N1P2 and P2N2 during the experiment were analyzed by increasing stimuli repetitions. The effect of stimulus parameter adjustments on GPI ratios was evaluated. No-gap-intense sound stimuli elicited greater peak amplitudes than gap-intense sound stimuli, and significant differences were found across all peaks. The overall mean inhibition ratios were significantly lower than 1.0, where the value 1.0 indicates that there were no differences between gap-intense and no-gap-intense sound responses. The initial decline in GPI ratios was shown in N1P2 and P2N2 complexes, and this reduction was nearly complete after 100 stimulus repetitions. Significant effects of gap length and interstimulus interval on GPI ratios were observed. We found significant inhibition of ALR peak amplitudes in performing the gap-intense sound paradigm in healthy subjects. The N1P2 complex represented GPI well in terms of suppression degree and test-retest reliability. Our findings offer practical information for the comparative study of healthy subjects and tinnitus patients using the gap-intense sound paradigm with the ALR. © 2015 Society for Psychophysiological Research.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu Shengwei; Yu Jiaguo
Bi{sub 2}WO{sub 6} hierarchical multilayered flower-like assemblies are fabricated on a large scale by a simple hydrothermal method in the presence of polymeric poly(sodium 4-styrenesulfonate). Such 3D Bi{sub 2}WO{sub 6} assemblies are constructed from orderly arranged 2D layers, which are further composed of a large number of interconnected nanoplates with a mean side length of ca. 50 nm. The bimodal mesopores associated with such hierarchical assembly exhibit peak mesopore size of ca. 4 nm for the voids within a layer, and peak mesopore size of ca. 40 nm corresponding to the interspaces between stacked layers, respectively. The formation process ismore » discussed on the basis of the results of time-dependent experiments, which support a novel 'coupled cooperative assembly and localized ripening' formation mechanism. More interestingly, we have noticed that the collective effect related to such hierarchical assembly induces a significantly enhanced optical absorbance in the UV-visible region. This work may shed some light on the design of complex architectures and exploitation of their potential applications. - Graphical abstract: Bi{sub 2}WO{sub 6} hierarchical multilayered flower-like assemblies are fabricated on a large scale by a simple hydrothermal method in the presence of polymeric poly(sodium 4-styrenesulfonate)« less
Conlisk, N.; Gray, H.; Pankaj, P.; Howie, C. R.
2012-01-01
Objectives Orthopaedic surgeons use stems in revision knee surgery to obtain stability when metaphyseal bone is missing. No consensus exists regarding stem size or method of fixation. This in vitro study investigated the influence of stem length and method of fixation on the pattern and level of relative motion at the bone–implant interface at a range of functional flexion angles. Methods A custom test rig using differential variable reluctance transducers (DVRTs) was developed to record all translational and rotational motions at the bone–implant interface. Composite femurs were used. These were secured to permit variation in flexion angle from 0° to 90°. Cyclic loads were applied through a tibial component based on three peaks corresponding to 0°, 10° and 20° flexion from a normal walking cycle. Three different femoral components were investigated in this study for cementless and cemented interface conditions. Results Relative motions were found to increase with flexion angle. Stemmed implants reduced relative motions in comparison to stemless implants for uncemented constructs. Relative motions for cemented implants were reduced to one-third of their equivalent uncemented constructs. Conclusions Stems are not necessary for cemented implants when the metaphyseal bone is intact. Short cemented femoral stems confer as much stability as long uncemented stems. PMID:23610659
A Semi-Automatic Method for Image Analysis of Edge Dynamics in Living Cells
Huang, Lawrence; Helmke, Brian P.
2011-01-01
Spatial asymmetry of actin edge ruffling contributes to the process of cell polarization and directional migration, but mechanisms by which external cues control actin polymerization near cell edges remain unclear. We designed a quantitative image analysis strategy to measure the spatiotemporal distribution of actin edge ruffling. Time-lapse images of endothelial cells (ECs) expressing mRFP-actin were segmented using an active contour method. In intensity line profiles oriented normal to the cell edge, peak detection identified the angular distribution of polymerized actin within 1 µm of the cell edge, which was localized to lamellipodia and edge ruffles. Edge features associated with filopodia and peripheral stress fibers were removed. Circular statistical analysis enabled detection of cell polarity, indicated by a unimodal distribution of edge ruffles. To demonstrate the approach, we detected a rapid, nondirectional increase in edge ruffling in serum-stimulated ECs and a change in constitutive ruffling orientation in quiescent, nonpolarized ECs. Error analysis using simulated test images demonstrate robustness of the method to variations in image noise levels, edge ruffle arc length, and edge intensity gradient. These quantitative measurements of edge ruffling dynamics enable investigation at the cellular length scale of the underlying molecular mechanisms regulating actin assembly and cell polarization. PMID:21643526
MODELING TIME DISPERSION DUE TO OPTICAL PATH LENGTH DIFFERENCES IN SCINTILLATION DETECTORS*
Moses, W.W.; Choong, W.-S.; Derenzo, S.E.
2015-01-01
We characterize the nature of the time dispersion in scintillation detectors caused by path length differences of the scintillation photons as they travel from their generation point to the photodetector. Using Monte Carlo simulation, we find that the initial portion of the distribution (which is the only portion that affects the timing resolution) can usually be modeled by an exponential decay. The peak amplitude and decay time depend both on the geometry of the crystal, the position within the crystal that the scintillation light originates from, and the surface finish. In a rectangular parallelpiped LSO crystal with 3 mm × 3 mm cross section and polished surfaces, the decay time ranges from 10 ps (for interactions 1 mm from the photodetector) up to 80 ps (for interactions 50 mm from the photodetector). Over that same range of distances, the peak amplitude ranges from 100% (defined as the peak amplitude for interactions 1 mm from the photodetector) down to 4% for interactions 50 mm from the photodetector. Higher values for the decay time are obtained for rough surfaces, but the exact value depends on the simulation details. Estimates for the decay time and peak amplitude can be made for different cross section sizes via simple scaling arguments. PMID:25729464
Modeling Time Dispersion Due to Optical Path Length Differences in Scintillation Detectors
Moses, W. W.; Choong, W. -S.; Derenzo, S. E.
2014-08-20
In this paper, we characterize the nature of the time dispersion in scintillation detectors caused by path length differences of the scintillation photons as they travel from their generation point to the photodetector. Using Monte Carlo simulation, we find that the initial portion of the distribution (which is the only portion that affects the timing resolution) can usually be modeled by an exponential decay. The peak amplitude and decay time depend both on the geometry of the crystal, the position within the crystal that the scintillation light originates from, and the surface finish. In a rectangular parallelpiped LSO crystal withmore » 3 mm × 3 mm cross section and polished surfaces, the decay time ranges from 10 ps (for interactions 1 mm from the photodetector) up to 80 ps (for interactions 50 mm from the photodetector). Over that same range of distances, the peak amplitude ranges from 100% (defined as the peak amplitude for interactions 1 mm from the photodetector) down to 4% for interactions 50 mm from the photodetector. Higher values for the decay time are obtained for rough surfaces, but the exact value depends on the simulation details. Finally, estimates for the decay time and peak amplitude can be made for different cross section sizes via simple scaling arguments.« less
Sun, Jie; Nwaru, Bright I; Hua, Jing; Li, Xiaohong; Wu, Zhuochun
2017-01-01
Objectives Infant body mass index (BMI) peak has proven to be a useful indicator for predicting childhood obesity risk in American and European populations. However, it has not been assessed in China. We characterised infant BMI trajectories in a Chinese longitudinal cohort and evaluated whether BMI peak can predict overweight and obesity at age 2 years. Methods Serial measurements (n=6–12) of weight and length were taken from healthy term infants (n=2073) in a birth cohort established in urban Shanghai. Measurements were used to estimate BMI growth curves from birth to 13.5 months using a polynomial regression model. BMI peak characteristics, including age (in months) and magnitude (BMI, in kg/m2) at peak and prepeak velocities (in kg/m2/month), were estimated. The relationship between infant BMI peak and childhood BMI at age 2 years was examined using binary logistic analysis. Results Mean age at peak BMI was 7.61 months, with a magnitude of 18.33 kg/m2. Boys (n=1022) had a higher average peak BMI (18.60 vs 18.07 kg/m2, p<0.001) and earlier average achievement of peak value (7.54 vs 7.67 months, p<0.05) than girls (n=1051). With 1 kg/m2 increase in peak BMI and 1 month increase in peak time, the risk of overweight at age 2 years increased by 2.11 times (OR 3.11; 95% CI 2.64 to 3.66) and 35% (OR 1.35; 95% CI 1.21 to 1.50), respectively. Similarly, higher BMI magnitude (OR 2.69; 95% CI 2.00 to 3.61) and later timing of infant BMI peak (OR 1.35; 95% CI 1.08 to 1.68) were associated with an increased risk of childhood obesity at age 2 years. Conclusions We have shown that infant BMI peak is valuable for predicting early childhood overweight and obesity in urban Shanghai. Because this is the first Chinese community-based cohort study of this nature, future research is required to examine infant populations in other areas of China. PMID:28988164
Coupling between absorption and scattering in disordered colloids
NASA Astrophysics Data System (ADS)
Stephenson, Anna; Hwang, Victoria; Park, Jin-Gyu; Manoharan, Vinothan N.
We aim to understand how scattering and absorption are coupled in disordered colloidal suspensions containing absorbing molecules (dyes). When the absorption length is shorter than the transport length, absorption dominates, and absorption and scattering can be seen as two additive effects. However, when the transport length is shorter than the absorption length, the scattering and absorption become coupled, as multiple scattering increases the path length of the light in the sample, leading to a higher probability of absorption. To quantify this synergistic effect, we measure the diffuse reflectance spectra of colloidal samples of varying dye concentrations, thicknesses, and particle concentrations, and we calculate the transport length and absorption length from our measurements, using a radiative transfer model. At particle concentrations so high that the particles form disordered packings, we find a minimum in the transport length. We show that selecting a dye where the absorption peak matches the location of the minimum in the transport length allows for enhanced absorption. Kraft-Heinz Corporation, NSF GRFP 2015200426.
Two-dimensional explosion experiments examining the interaction between a blast wave and a sand hill
NASA Astrophysics Data System (ADS)
Sugiyama, Y.; Izumo, M.; Ando, H.; Matsuo, A.
2018-05-01
Two-dimensional explosion experiments were conducted to discuss the interaction between a blast wave and sand and show the mitigation effect of the sand on the blast wave. The explosive used was a detonating cord 1.0 m in length, which was initiated in a sand hill shaped like a triangular prism and whose cross section was an isosceles triangle with base angles of 30°. Sand-hill heights of 30 and 60 mm were used as parameters to discuss the effect of sand mass upon blast-wave strength. The interaction of the blast wave with the sand/air interface causes multiple peaks in the blast wave, which are induced by successive transmissions at the interface. The increase in the sand mass further mitigates the blast parameters of peak overpressure and positive impulse. The results of this experiment can be utilized to validate the numerical method of solving the problem of interaction between a compressible fluid and a particle layer.
Two-dimensional explosion experiments examining the interaction between a blast wave and a sand hill
NASA Astrophysics Data System (ADS)
Sugiyama, Y.; Izumo, M.; Ando, H.; Matsuo, A.
2018-02-01
Two-dimensional explosion experiments were conducted to discuss the interaction between a blast wave and sand and show the mitigation effect of the sand on the blast wave. The explosive used was a detonating cord 1.0 m in length, which was initiated in a sand hill shaped like a triangular prism and whose cross section was an isosceles triangle with base angles of 30°. Sand-hill heights of 30 and 60 mm were used as parameters to discuss the effect of sand mass upon blast-wave strength. The interaction of the blast wave with the sand/air interface causes multiple peaks in the blast wave, which are induced by successive transmissions at the interface. The increase in the sand mass further mitigates the blast parameters of peak overpressure and positive impulse. The results of this experiment can be utilized to validate the numerical method of solving the problem of interaction between a compressible fluid and a particle layer.
Estimating flood hydrographs for urban basins in North Carolina
Mason, R.R.; Bales, J.D.
1996-01-01
A dimensionless hydrograph for North Carolina was developed from data collected in 29 urban and urbanizing basins in the State. The dimen- sionless hydrograph can be used with an estimate of peak flow and basin lagtime to synthesize a design flood hydrograph for urban basins in North Carolina. Peak flows can be estimated from a number of avail- able techniques; a procedure for estimating basin lagtime from main channel length, stream slope, and percentage of impervious area was developed from data collected at 50 sites and is presented in this report. The North Carolina dimensionless hydrograph provides satis- factory predictions of flood hydrographs in all regions of the State except for basins in or near Asheville where the method overestimated 11 of 12 measured hydrographs. A previously developed dimensionless hydrograph for urban basins in the Piedmont and upper Coastal Plain of South Carolina provides better flood-hydrograph predictions for the Asheville basins and has a standard error of 21 percent as compared to 41 percent for the North Carolina dimensionless hydrograph.
Ishihara, Takashi; Kadoya, Toshihiko; Yamamoto, Shuichi
2007-08-24
We applied the model described in our previous paper to the rapid scale-up in the ion exchange chromatography of proteins, in which linear flow velocity, column length and gradient slope were changed. We carried out linear gradient elution experiments, and obtained data for the peak salt concentration and peak width. From these data, the plate height (HETP) was calculated as a function of the mobile phase velocity and iso-resolution curve (the separation time and elution volume relationship for the same resolution) was calculated. The scale-up chromatography conditions were determined by the iso-resolution curve. The scale-up of the linear gradient elution from 5 to 100mL and 2.5L column sizes was performed both by the separation of beta-lactoglobulin A and beta-lactoglobulin B with anion-exchange chromatography and by the purification of a recombinant protein with cation-exchange chromatography. Resolution, recovery and purity were examined in order to verify the proposed method.
AERODYNAMIC SOUND OF A BODY IN ARBITRARY, DEFORMABLE MOTION, WITH APPLICATION TO PHONATION
Howe, M. S.; McGowan, R. S.
2012-01-01
The method of tailored Green’s functions advocated by Doak (Proceedings of the Royal Society A254 (1960) 129 – 145.) for the solution of aeroacoustic problems is used to analyse the contribution of the mucosal wave to self-sustained modulation of air flow through the glottis during the production of voiced speech. The amplitude and phase of the aerodynamic surface force that maintains vocal fold vibration are governed by flow separation from the region of minimum cross-sectional area of the glottis, which moves back and forth along its effective length accompanying the mucosal wave peak. The correct phasing is achieved by asymmetric motion of this peak during the opening and closing phases of the glottis. Limit cycle calculations using experimental data of Berry et al. (Journal of the Acoustical Society of America 110 (2001) 2539 – 2547.) obtained using an excised canine hemilarynx indicate that the mechanism is robust enough to sustain oscillations over a wide range of voicing conditions. PMID:24031098
Theoretical investigation and optimization of fiber grating based slow light
NASA Astrophysics Data System (ADS)
Wang, Qi; Wang, Peng; Du, Chao; Li, Jin; Hu, Haifeng; Zhao, Yong
2017-07-01
On the edge of bandgap in a fiber grating, narrow peaks of high transimittivity exist at frequencies where light interferes constructively in the forward direction. In the vicinity of these transmittivity peaks, light reflects back and forth numerous times across the periodic structure and experiences a large group delay. In order to generate the extremely slow light in fiber grating for applications, in this research, the common sense of formation mechanism of slow light in fiber grating was introduced. The means of producing and operating fiber grating was studied to support structural slow light with a group index that can be in principle as high as several thousand. The simulations proceeded by transfer matrix method in the paper were presented to elucidate how the fiber grating parameters effect group refractive index. The main parameters that need to be optimized include grating length, refractive index contrast, grating period, loss coefficient, chirp and apodization functions, those can influence fiber grating characteristics.
2011-04-01
this limitation the length of the windows needs to be shortened. It is also leads to a narrower confidence interval, see Figure 2.9. 82 The " big ...least one event will occur within the window. The windows are then grouped in sets of two and the process is reapeated for a window size twice as big ...0 505 T. Fu 1 506 D. Walden 1 508 J. Brown 1 55 T.Applebee 0 55 M. Dipper 1 551 T. Smith I 551 C. Bassler 3 3 551 V. Belenky 1 551 W. Belknap
NASA Astrophysics Data System (ADS)
Sahu, Harikrishna; Shukla, Rishabh; Goswami, Juri; Gaur, Priyank; Panda, Aditya N.
2018-01-01
Structural and optoelectronic properties of phenylene-furan, phenylene-pyrrole and phenylene-thiophene oligomers are reported using density functional theory methods. Studies reveal that stabilities of conformers change with increasing chain length, and helical conformers are energetically feasible for large oligomers of the studied systems, due to stacking interactions between adjacent helical turns. Absorption spectra of helices are dominated by multiple number of electronic transitions other than the S0 →S1 , involving orbitals other than the HOMO/LUMO. All studied helices are optically active having similar pattern of negative and positive peaks in the CD spectra.
Ordinal pattern statistics for the assessment of heart rate variability
NASA Astrophysics Data System (ADS)
Graff, G.; Graff, B.; Kaczkowska, A.; Makowiec, D.; Amigó, J. M.; Piskorski, J.; Narkiewicz, K.; Guzik, P.
2013-06-01
The recognition of all main features of a healthy heart rhythm (the so-called sinus rhythm) is still one of the biggest challenges in contemporary cardiology. Recently the interesting physiological phenomenon of heart rate asymmetry has been observed. This phenomenon is related to unbalanced contributions of heart rate decelerations and accelerations to heart rate variability. In this paper we apply methods based on the concept of ordinal pattern to the analysis of electrocardiograms (inter-peak intervals) of healthy subjects in the supine position. This way we observe new regularities of the heart rhythm related to the distribution of ordinal patterns of lengths 3 and 4.
Mc Fadden, Kim; Gillespie, John; Carney, Brian; O'Driscoll, Daniel
2006-07-07
A rapid and selective HPLC method using monolithic columns was developed for the separation and quantification of the principal amphetamines in ecstasy tablets. Three monolithic (Chromolith RP18e) columns of different lengths (25, 50 and 100 mm) were assessed. Validation studies including linearity, selectivity, precision, accuracy and limit of detection and quantification were carried out using the Chromolith SpeedROD, RP-18e, 50 mm x 4.6 mm column. Column backpressure and van Deemter plots demonstrated that monolithic columns provide higher efficiency at higher flow rates when compared to particulate columns without the loss of peak resolution. Application of the monolithic column to a large number of ecstasy tablets seized in Ireland ensured its suitability for the routine analysis of ecstasy tablets.
Rajan, Shiny Amala Priya; Towe, Bruce C
2014-01-01
A non-invasive method is developed to monitor rapid changes in blood glucose levels in diabetic patients. The system depends on an optical cell built with a LED that emits light of wavelength 535nm, which is a peak absorbance of hemoglobin. As the glucose concentration in blood decreases, its osmolarity also decreases and the Red Blood Cells (RBCs) swell and decrease the path length absorption coefficient. Decreasing absorption coefficient increases the transmission of light through the whole blood. The system was tested with a constructed optical cell that held whole blood in a capillary tube. As expected the light transmitted to the photodiode increases with decreasing glucose concentration. The average response time of the system was between 30-40 seconds.
Liu, Guigen; Sheng, Qiwen; Hou, Weilin; Han, Ming
2016-11-14
In practical applications of fiber optic sensors based on Fabry-Perot interferometers (FPIs), the lead-in optical fiber often experiences dynamic or static bending due to environmental perturbations or limited installation space. Bending introduces wavelength-dependent losses to the sensors, which can cause erroneous readings for sensors based on wavelength demodulation interrogation. Here, we investigate the bending-induced wavelength shift (BIWS) to sensors based on FPIs. Partially explicit expressions of BIWSs for the reflection fringe peaks and valleys have been derived for sensors based on low-finesse FPI. The theoretical model predicts these findings: 1) provided that a fringe peak experiences the same modulation slope by bending losses with a fringe valley, BIWSs for the peak and valley have opposite signs and the BIWS for the valley has a smaller absolute value; 2) BIWS is a linear function of the length of the bending section; 3) a FPI with higher visibility and longer optical path length is more resistant to the influence of bending. Experiments have been carried out and the results agree well with the theoretical predictions.
Kocsis, E; Trus, B L; Steer, C J; Bisher, M E; Steven, A C
1991-08-01
We have developed computational techniques that allow image averaging to be applied to electron micrographs of filamentous molecules that exhibit tight and variable curvature. These techniques, which involve straightening by cubic-spline interpolation, image classification, and statistical analysis of the molecules' curvature properties, have been applied to purified brain clathrin. This trimeric filamentous protein polymerizes, both in vivo and in vitro, into a wide range of polyhedral structures. Contrasted by low-angle rotary shadowing, dissociated clathrin molecules appear as distinctive three-legged structures, called "triskelions" (E. Ungewickell and D. Branton (1981) Nature 289, 420). We find triskelion legs to vary from 35 to 62 nm in total length, according to an approximately bell-shaped distribution (mu = 51.6 nm). Peaks in averaged curvature profiles mark hinges or sites of enhanced flexibility. Such profiles, calculated for each length class, show that triskelion legs are flexible over their entire lengths. However, three curvature peaks are observed in every case: their locations define a proximal segment of systematically increasing length (14.0-19.0 nm), a mid-segment of fixed length (approximately 12 nm), and a rather variable end-segment (11.6-19.5 nm), terminating in a hinge just before the globular terminal domain (approximately 7.3 nm diameter). Thus, two major factors contribute to the overall variability in leg length: (1) stretching of the proximal segment and (2) stretching of the end-segment and/or scrolling of the terminal domain. The observed elasticity of the proximal segment may reflect phosphorylation of the clathrin light chains.
Experimental and Numerical Study for Flow across a Cube at various Reynolds numbers
NASA Astrophysics Data System (ADS)
Khan, Majid Hassan; Agrawal, Amit; Sharma, Atul
2017-11-01
Cube is an archetypal three dimensional bluff body and flow around a rigidly suspended cube is one of the least studied. The present work explains the flow behaviour in the wake of a cube. Lattice Boltzmann Method (LBM) simulations are used for Re = 84 to 780 and Particle Image Velocimetry (PIV) measurements are reported for Re = 550 to 55000. Mean and rms velocities at different axial locations are examined. Double peaks for rms velocity profiles at different axial locations in the wake is observed. Recirculation length increases at lower Re and then decreases at higher Re with a critical Re between 500 and 1000. An inverse relationship is found for the coefficient of drag and recirculation length in the steady range. Wake behaviour becomes non-dependent after Re = 1620. Using the nature of recirculation bubbles in the near wake, four flow regimes are established utilizing the LBM results and the categorization extends to the information at higher Re obtained using PIV. Drag coefficients are obtained using modified wake survey method and compared with established correlations for a cube and a sphere. Numerical results explain the relationship between side-forces at lower Re.
Conceptual Core Analysis of Long Life PWR Utilizing Thorium-Uranium Fuel Cycle
NASA Astrophysics Data System (ADS)
Rouf; Su'ud, Zaki
2016-08-01
Conceptual core analysis of long life PWR utilizing thorium-uranium based fuel has conducted. The purpose of this study is to evaluate neutronic behavior of reactor core using combined thorium and enriched uranium fuel. Based on this fuel composition, reactor core have higher conversion ratio rather than conventional fuel which could give longer operation length. This simulation performed using SRAC Code System based on library SRACLIB-JDL32. The calculation carried out for (Th-U)O2 and (Th-U)C fuel with uranium composition 30 - 40% and gadolinium (Gd2O3) as burnable poison 0,0125%. The fuel composition adjusted to obtain burn up length 10 - 15 years under thermal power 600 - 1000 MWt. The key properties such as uranium enrichment, fuel volume fraction, percentage of uranium are evaluated. Core calculation on this study adopted R-Z geometry divided by 3 region, each region have different uranium enrichment. The result show multiplication factor every burn up step for 15 years operation length, power distribution behavior, power peaking factor, and conversion ratio. The optimum core design achieved when thermal power 600 MWt, percentage of uranium 35%, U-235 enrichment 11 - 13%, with 14 years operation length, axial and radial power peaking factor about 1.5 and 1.2 respectively.
Yu, Y T; Tuan, P H; Chang, K C; Hsieh, Y H; Huang, K F; Chen, Y F
2016-01-11
Broad-area vertical-cavity surface-emitting lasers (VCSELs) with different cavity sizes are experimentally exploited to manifest the influence of the finite confinement strength on the path-length distribution of quantum billiards. The subthreshold emission spectra of VCSELs are measured to obtain the path-length distributions by using the Fourier transform. It is verified that the number of the resonant peaks in the path-length distribution decreases with decreasing the confinement strength. Theoretical analyses for finite-potential quantum billiards are numerically performed to confirm that the mesoscopic phenomena of quantum billiards with finite confinement strength can be analogously revealed by using broad-area VCSELs.
NASA Technical Reports Server (NTRS)
Stone, N. H.
1981-01-01
An experimental investigation of the disturbed flow field created by conducting bodies in a mesosonic, collisionless plasma stream is reported. The mid-wake region is investigated, where, for bodies of the order of a Debye length in size, the focused ion streams converge to form a significant current density peak on the wake axis. A parametric description is obtained of the behavior of the amplitude, width, and position of this peak. The results also indicate that portions of the axial ion peak are created by additional mechanisms and that body geometry affects the mid-wake structure only when the sheath is sufficiently thin to conform to the shape of the body.
Characteristics of a Strongly-Pulsed Non-Premixed Jet Flame in Cross-flow
NASA Astrophysics Data System (ADS)
Gamba, Mirko; Clemens, Noel T.; Ezekoye, Ofodike A.
2006-11-01
The effects of large-amplitude, high-frequency harmonic forcing of turbulent nonpremixed hydrogen/methane jet flames in cross-flow (JFICF) are investigated experimentally. Flame lengths, penetration lengths, and mixing characteristics are studied using flame luminosity imaging, planar laser Mie scattering visualization and particle image velocimetry. Mean jet Reynolds numbers of 1,600 and 3,250 (peak Re ˜2,500--6,500) with corresponding mean momentum flux ratios, r, of 1.9 and 3.7 (peak r ˜2.6--8.3) are considered. Forcing frequencies of 100 Hz and 300 Hz with amplitudes of ˜60%--300% are investigated. Consistent with previous work, a drastic decrease in flame length and soot emission, an increase in flame penetration and an improved jet fuel/cross-flow air mixing are observed for the larger forcing amplitude cases. Partial pre-mixing induced by near-field reverse flow, near-field vortex/vortex interaction and large-scale stirring, rendered stronger by large forcing amplitudes and frequencies, are thought to play a key role on the observed effects.
NASA Astrophysics Data System (ADS)
Li, Jun; Zhang, Song Bin; Ye, Bang Jiao; Wang, Jian Guo; Janev, R. K.
2017-09-01
Low-energy electron elastic scattering and impact ionization with hydrogenlike helium in Debye plasmas have been investigated by employing the exterior complex scaling method. The interactions between charged particles in the plasmas have been represented by Debye-Hückel potentials. The 1 s -1 s elastic collision strengths below the n =2 excitation threshold of He+ dominated by resonance structures are calculated for different screening lengths. As the screening strength increases, the resonance peaks studied [2(1,0) 2 +1Se,3Po,1De , and 2(0,1) 2 +1Po] exhibit blueshifts and then redshifts with a further increase of the screening strength, which results in dramatic changes of the collision strengths. It is found that these dynamic variation features of the resonances are related to the changes of energy levels of He+ in the screened potential and geometric configurations of resonances. Triple-differential-ionization cross sections in coplanar geometries at 6-Ry incident electron energy are also reported, significant changes are observed with varying screening length.
Bulgari, Daniela; Casati, Paola; Brusetti, Lorenzo; Quaglino, Fabio; Brasca, Milena; Daffonchio, Daniele; Bianco, Piero Attilio
2009-08-01
Diversity of bacterial endophytes associated with grapevine leaf tissues was analyzed by cultivation and cultivation-independent methods. In order to identify bacterial endophytes directly from metagenome, a protocol for bacteria enrichment and DNA extraction was optimized. Sequence analysis of 16S rRNA gene libraries underscored five diverse Operational Taxonomic Units (OTUs), showing best sequence matches with gamma-Proteobacteria, family Enterobacteriaceae, with a dominance of the genus Pantoea. Bacteria isolation through cultivation revealed the presence of six OTUs, showing best sequence matches with Actinobacteria, genus Curtobacterium, and with Firmicutes genera Bacillus and Enterococcus. Length Heterogeneity-PCR (LH-PCR) electrophoretic peaks from single bacterial clones were used to setup a database representing the bacterial endophytes identified in association with grapevine tissues. Analysis of healthy and phytoplasma-infected grapevine plants showed that LH-PCR could be a useful complementary tool for examining the diversity of bacterial endophytes especially for diversity survey on a large number of samples.
Travelers' Health: Cruise Ship Travel
... Motion Sickness ). PRECAUTIONS FOR CRUISE SHIP TRAVELERS Pretravel Evaluate the type and length of the planned cruise ... Peake DE, Gray CL, Ludwig MR, Hill CD. Descriptive epidemiology of injury and illness among cruise ship ...
Kinematic and ground reaction force accommodation during weighted walking.
James, C Roger; Atkins, Lee T; Yang, Hyung Suk; Dufek, Janet S; Bates, Barry T
2015-12-01
Weighted walking is a functional activity common in daily life and can influence risks for musculoskeletal loading, injury and falling. Much information exists about weighted walking during military, occupational and recreational tasks, but less is known about strategies used to accommodate to weight carriage typical in daily life. The purposes of the study were to examine the effects of weight carriage on kinematics and peak ground reaction force (GRF) during walking, and explore relationships between these variables. Twenty subjects walked on a treadmill while carrying 0, 44.5 and 89 N weights in front of the body. Peak GRF, sagittal plane joint/segment angular kinematics, stride length and center of mass (COM) vertical displacement were measured. Changes in peak GRF and displacement variables between weight conditions represented accommodation. Effects of weight carriage were tested using analysis of variance. Relationships between peak GRF and kinematic accommodation variables were examined using correlation and regression. Subjects were classified into sub-groups based on peak GRF responses and the correlation analysis was repeated. Weight carriage increased peak GRF by an amount greater than the weight carried, decreased stride length, increased vertical COM displacement, and resulted in a more extended and upright posture, with less hip and trunk displacement during weight acceptance. A GRF increase was associated with decreases in hip extension (|r|=.53, p=.020) and thigh anterior rotation (|r|=.57, p=.009) displacements, and an increase in foot anterior rotation displacement (|r|=.58, p=.008). Sub-group analysis revealed that greater GRF increases were associated with changes at multiple sites, while lesser GRF increases were associated with changes in foot and trunk displacement. Weight carriage affected walking kinematics and revealed different accommodation strategies that could have implications for loading and stability. Copyright © 2015 Elsevier B.V. All rights reserved.
Surface Peroneal Nerve Stimulation in Lower Limb Hemiparesis: Effect on Quantitative Gait Parameters
Sheffler, Lynne R.; Taylor, Paul N.; Bailey, Stephanie Nogan; Gunzler, Douglas D.; Buurke, Jaap H.; IJzerman, Maarten J.; Chae, John
2015-01-01
Objective To evaluate possible mechanisms for functional improvement and compare ambulation training with surface peroneal nerve stimulation (PNS) versus usual care (UC) via quantitative gait analysis. Design Randomized controlled clinical trial. Setting Teaching hospital of academic medical center. Participants 110 chronic stroke survivors (> 12-wks post-stroke) with unilateral hemiparesis. Interventions Subjects were randomized to a surface PNS device or UC intervention. Subjects were treated for 12-wks and followed for 6-months post-treatment. Main Outcome Measures Spatiotemporal, kinematic, and kinetic parameters of gait. Results Cadence (F3,153=5.81, p=.012), stride length (F3,179=20.01, p<.001), walking speed (F3,167=18.2, p<.001), anterior posterior ground reaction force (F3,164=6.61, p=.004), peak hip power in pre-swing (F3,156=8.76, p<.001), and peak ankle power at push-off (F3,149=6.38, p=.005) all improved with respect to time. However, peak ankle DF in swing (F3,184=4.99, p=.031) worsened. In general, the greatest change for all parameters occurred during the treatment period. There was no significant treatment group by time interaction effects for any of the spatiotemporal, kinematic, or kinetic parameters. Conclusions Gait training with PNS and usual care was associated with improvements in peak hip power in pre-swing and peak ankle power at push-off, which may have resulted in improved cadence, stride length, and walking speed; however, there were no differences between treatment groups. Both treatment groups also experienced a decrease in peak ankle DF in swing, though the clinical implications of this finding are unclear. PMID:25802966
Coatings for FEL optics: preparation and characterization of B4C and Pt
Störmer, Michael; Siewert, Frank; Horstmann, Christian; Buchheim, Jana; Gwalt, Grzegorz
2018-01-01
Large X-ray mirrors are required for beam transport at both present-day and future free-electron lasers (FELs) and synchrotron sources worldwide. The demand for large mirrors with lengths up to 1 m single layers consisting of light or heavy elements has increased during the last few decades. Accordingly, surface finishing technology is now able to produce large substrate lengths with micro-roughness on the sub-nanometer scale. At the Helmholtz-Zentrum Geesthacht (HZG), a 4.5 m-long sputtering facility enables us to deposit a desired single-layer material some tens of nanometers thick. For the European XFEL project, the shape error should be less than 2 nm over the whole 1 m X-ray mirror length to ensure the safe and efficient delivery of X-ray beams to the scientific instruments. The challenge is to achieve thin-film deposition on silicon substrates, benders and gratings without any change in mirror shape. Thin films of boron carbide and platinum with a thickness in the range 30–100 nm were manufactured using the HZG sputtering facility. This setup is able to cover areas of up to 1500 mm × 120 mm in one step using rectangular sputtering sources. The coatings produced were characterized using various thin-film methods. It was possible to improve the coating process to achieve a very high uniformity of the layer thickness. The movement of the substrate in front of the sputtering source has been optimized. A variation in B4C layer thickness below 1 nm (peak-to-valley) was achieved at a mean thickness of 51.8 nm over a deposition length of 1.5 m. In the case of Pt, reflectometry and micro-roughness measurements were performed. The uniformity in layer thickness was about 1 nm (peak-to-valley). The micro-roughness of the Pt layers showed no significant change in the coated state for layer thicknesses of 32 nm and 102 nm compared with the uncoated substrate state. The experimental results achieved will be discussed with regard to current restrictions and future developments. PMID:29271760
Coatings for FEL optics: preparation and characterization of B4C and Pt.
Störmer, Michael; Siewert, Frank; Horstmann, Christian; Buchheim, Jana; Gwalt, Grzegorz
2018-01-01
Large X-ray mirrors are required for beam transport at both present-day and future free-electron lasers (FELs) and synchrotron sources worldwide. The demand for large mirrors with lengths up to 1 m single layers consisting of light or heavy elements has increased during the last few decades. Accordingly, surface finishing technology is now able to produce large substrate lengths with micro-roughness on the sub-nanometer scale. At the Helmholtz-Zentrum Geesthacht (HZG), a 4.5 m-long sputtering facility enables us to deposit a desired single-layer material some tens of nanometers thick. For the European XFEL project, the shape error should be less than 2 nm over the whole 1 m X-ray mirror length to ensure the safe and efficient delivery of X-ray beams to the scientific instruments. The challenge is to achieve thin-film deposition on silicon substrates, benders and gratings without any change in mirror shape. Thin films of boron carbide and platinum with a thickness in the range 30-100 nm were manufactured using the HZG sputtering facility. This setup is able to cover areas of up to 1500 mm × 120 mm in one step using rectangular sputtering sources. The coatings produced were characterized using various thin-film methods. It was possible to improve the coating process to achieve a very high uniformity of the layer thickness. The movement of the substrate in front of the sputtering source has been optimized. A variation in B 4 C layer thickness below 1 nm (peak-to-valley) was achieved at a mean thickness of 51.8 nm over a deposition length of 1.5 m. In the case of Pt, reflectometry and micro-roughness measurements were performed. The uniformity in layer thickness was about 1 nm (peak-to-valley). The micro-roughness of the Pt layers showed no significant change in the coated state for layer thicknesses of 32 nm and 102 nm compared with the uncoated substrate state. The experimental results achieved will be discussed with regard to current restrictions and future developments.
NASA Astrophysics Data System (ADS)
Hoynant, G.
2007-12-01
Fourier analysis allows to identify periodical components in a time series of measurements under the form of a spectrum of the periodical components mathematically included in the series. The reading of a spectrum is often delicate and contradictory interpretations can be presented in some cases as for the luminosity of Seyfert galaxy NGC 4151 despite the very large number of observations since 1968. The present study identifies the causes of these difficulties thanks to an experimental approach based on analysis of synthetic series with one periodic component only. The total duration of the campaign must be long as compared to the periods to be identified: this ratio governs the separation capability of the spectral analysis. A large number of observations is obviously favourable but the intervals between measurements are not critical : the analysis can accommodate intervals significantly longer than the periods to be identified. But interruptions along the campaign, with separate sessions of observations, make the physical understanding of the analysis difficult and sometimes impossible. An analysis performed on an imperfect series shows peaks which are not significant of the signal itself but of the chronological distribution of the measurements. These chronological peaks are becoming numerous and important when there are vacancy periods in the campaign. A method for authentication of a peak as a peak of the signal is to cut the chronological series in pieces with the same length than the period to identify and to superpose all these pieces. The present study shows that some chronological peaks can exhibit superposition graphics almost as clear as those for the signal peaks. Practically, the search for periodical components necessitates to organise the campaign specifically with a neutral chronological distribution of measurements without vacancies and the authentication of a peak as a peak of the signal requires a dominating amplitude or a graphic of periodical superposition significantly clearer than for any peak with a comparable or bigger amplitude.
Hess, Melanie K.; Hess, Andrew S.; Garrick, Dorian J.
2016-01-01
Gender of the calf whose birth initiates lactation could influence whole lactation milk yield of the dam due to hormonal influences on mammary gland development, or through calf gender effects on gestation length. Fetal gender could influence late lactation yields because cows become pregnant at peak lactation. The effects of calf gender sequences in parities 1–3 were assessed by separately fitting animal models to datasets from New Zealand comprising 274 000 Holstein Friesian and 85 000 Jersey cows, decreasing to 12 000 and 4 000 cows by parity 3. The lactation initiated by the birth of a female rather than a male calf was associated with a 0.33–1.1% (p≤0.05) higher milk yield. Female calf gender had carryover effects associated with higher milk yield in second lactations for Holstein Friesians (0.24%; p = 0.01) and third lactations for Jerseys (1.1%; p = 0.01). Cows giving birth to bull calves have 2 day longer gestations, which reduces lactation length in seasonal calving herds. Adding a covariate for lactation length to the animal model eroded some of these calf gender effects, such that calving a female led to higher milk yield only for second lactation Holstein Friesians (1.6%; p = 0.002). The interval centering method generates lower estimates of whole lactation yield when Wood’s lactation curves are shifted to the right by 2 days for male calves and this explained the higher yield in female calves when differences in lactation length were considered. Correlations of estimated breeding values between models including or excluding calf gender sequence were 1.00 for bulls or cows. Calf gender primarily influences milk yield through increased gestation length of male calves, and bias associated with the interval centering method used to estimate whole lactation milk yields. Including information on calf gender is unlikely to have an effect on selection response in New Zealand dairy cattle. PMID:26974166
NASA Astrophysics Data System (ADS)
Koshti, Ajay M.
2015-04-01
The paper provides information on a new infrared (IR) image contrast data post-processing method that involves converting raw data to normalized contrast versus time evolutions from the flash infrared thermography inspection video data. Thermal measurement features such as peak contrast, peak contrast time, persistence time, and persistence energy are calculated from the contrast evolutions. In addition, simulation of the contrast evolution is achieved through calibration on measured contrast evolutions from many flat bottom holes in a test plate of the subject material. The measurement features are used to monitor growth of anomalies and to characterize the void-like anomalies. The method was developed to monitor and analyze void-like anomalies in reinforced carbon-carbon (RCC) materials used on the wing leading edge of the NASA Space Shuttle Orbiters, but the method is equally applicable to other materials. The thermal measurement features relate to the anomaly characteristics such as depth and size. Calibration of the contrast is used to provide an assessment of the anomaly depth and width which correspond to the depth and diameter of the equivalent flat bottom hole (EFBH) from the calibration data. An edge detection technique called the half-max is used to measure width and length of the anomaly. Results of the half-max width and the EFBH diameter are compared with actual widths to evaluate utility of IR Contrast method. Some thermal measurements relate to gap thickness of the delaminations. Results of IR Contrast method on RCC hardware are provided. Keywords: normalized contrast, flash infrared thermography.
NASA Astrophysics Data System (ADS)
Liu, Lei; Guo, Rui; Wu, Jun-an
2017-02-01
Crosstalk is a main factor for wrong distance measurement by ultrasonic sensors, and this problem becomes more difficult to deal with under Doppler effects. In this paper, crosstalk reduction with Doppler shifts on small platforms is focused on, and a fast echo matching algorithm (FEMA) is proposed on the basis of chaotic sequences and pulse coding technology, then verified through applying it to match practical echoes. Finally, we introduce how to select both better mapping methods for chaotic sequences, and algorithm parameters for higher achievable maximum of cross-correlation peaks. The results indicate the following: logistic mapping is preferred to generate good chaotic sequences, with high autocorrelation even when the length is very limited; FEMA can not only match echoes and calculate distance accurately with an error degree mostly below 5%, but also generates nearly the same calculation cost level for static or kinematic ranging, much lower than that by direct Doppler compensation (DDC) with the same frequency compensation step; The sensitivity to threshold value selection and performance of FEMA depend significantly on the achievable maximum of cross-correlation peaks, and a higher peak is preferred, which can be considered as a criterion for algorithm parameter optimization under practical conditions.
Canney, Michael S.; Bailey, Michael R.; Crum, Lawrence A.; Khokhlova, Vera A.; Sapozhnikov, Oleg A.
2008-01-01
Acoustic characterization of high intensity focused ultrasound (HIFU) fields is important both for the accurate prediction of ultrasound induced bioeffects in tissues and for the development of regulatory standards for clinical HIFU devices. In this paper, a method to determine HIFU field parameters at and around the focus is proposed. Nonlinear pressure waveforms were measured and modeled in water and in a tissue-mimicking gel phantom for a 2 MHz transducer with an aperture and focal length of 4.4 cm. Measurements were performed with a fiber optic probe hydrophone at intensity levels up to 24 000 W∕cm2. The inputs to a Khokhlov–Zabolotskaya–Kuznetsov-type numerical model were determined based on experimental low amplitude beam plots. Strongly asymmetric waveforms with peak positive pressures up to 80 MPa and peak negative pressures up to 15 MPa were obtained both numerically and experimentally. Numerical simulations and experimental measurements agreed well; however, when steep shocks were present in the waveform at focal intensity levels higher than 6000 W∕cm2, lower values of the peak positive pressure were observed in the measured waveforms. This underrepresentation was attributed mainly to the limited hydrophone bandwidth of 100 MHz. It is shown that a combination of measurements and modeling is necessary to enable accurate characterization of HIFU fields. PMID:19062878
Historical channel-planform change of the Little Colorado River near Winslow, Arizona
Block, Debra L.
2014-01-01
This study evaluates channel-planform adjustment on an alluvial reach of the Little Colorado River and documents the geomorphic evolution of the channel through an analysis of aerial photographs and orthophotographs for the period 1936–2010. The Little Colorado River has adjusted to the effects of an extreme flood in 1923 and a subsequent decline in peak discharge and mean annual flow by channel narrowing: the channel width and area of the river have decreased by approximately 90 percent over the study period. Although deposition historically exceeds erosion, lateral migration exacerbates localized erosion, particularly near hydraulic controls. Despite repeated cutoff and avulsion, the Little Colorado River has steadily increased in length and sinuosity over a period of 74 years. Changes in temperature and precipitation are likely affecting the discharge of the Little Colorado River near and downstream of Winslow, Ariz. Nonparametric methods of trend detection determine whether the probability distribution of temperature, precipitation, and peak streamflow has changed over time. Time-series plots of temperature and precipitation show statistically significant trends at the 99-percent-confidence level when evaluated with a Mann-Kendall test. An increasing trend was indicated in mean daily minimum air temperature (Tmin), whereas decreasing trends were indicated in both annual precipitation (Pann) and monsoon-seasonal precipitation (Pjas), as well as in peak discharge.
Impact evaluation of conducted UWB transients on loads in power-line networks
NASA Astrophysics Data System (ADS)
Li, Bing; Månsson, Daniel
2017-09-01
Nowadays, faced with the ever-increasing dependence on diverse electronic devices and systems, the proliferation of potential electromagnetic interference (EMI) becomes a critical threat for reliable operation. A typical issue is the electronics working reliably in power-line networks when exposed to electromagnetic environment. In this paper, we consider a conducted ultra-wideband (UWB) disturbance, as an example of intentional electromagnetic interference (IEMI) source, and perform the impact evaluation at the loads in a network. With the aid of fast Fourier transform (FFT), the UWB transient is characterized in the frequency domain. Based on a modified Baum-Liu-Tesche (BLT) method, the EMI received at the loads, with complex impedance, is computed. Through inverse FFT (IFFT), we obtain time-domain responses of the loads. To evaluate the impact on loads, we employ five common, but important quantifiers, i.e., time-domain peak, total signal energy, peak signal power, peak time rate of change and peak time integral of the pulse. Moreover, to perform a comprehensive analysis, we also investigate the effects of the attributes (capacitive, resistive, or inductive) of other loads connected to the network, the rise time and pulse width of the UWB transient, and the lengths of power lines. It is seen that, for the loads distributed in a network, the impact evaluation of IEMI should be based on the characteristics of the IEMI source, and the network features, such as load impedances, layout, and characteristics of cables.
Safety modeling of urban arterials in Shanghai, China.
Wang, Xuesong; Fan, Tianxiang; Chen, Ming; Deng, Bing; Wu, Bing; Tremont, Paul
2015-10-01
Traffic safety on urban arterials is influenced by several key variables including geometric design features, land use, traffic volume, and travel speeds. This paper is an exploratory study of the relationship of these variables to safety. It uses a comparatively new method of measuring speeds by extracting GPS data from taxis operating on Shanghai's urban network. This GPS derived speed data, hereafter called Floating Car Data (FCD) was used to calculate average speeds during peak and off-peak hours, and was acquired from samples of 15,000+ taxis traveling on 176 segments over 18 major arterials in central Shanghai. Geometric design features of these arterials and surrounding land use characteristics were obtained by field investigation, and crash data was obtained from police reports. Bayesian inference using four different models, Poisson-lognormal (PLN), PLN with Maximum Likelihood priors (PLN-ML), hierarchical PLN (HPLN), and HPLN with Maximum Likelihood priors (HPLN-ML), was used to estimate crash frequencies. Results showed the HPLN-ML models had the best goodness-of-fit and efficiency, and models with ML priors yielded estimates with the lowest standard errors. Crash frequencies increased with increases in traffic volume. Higher average speeds were associated with higher crash frequencies during peak periods, but not during off-peak periods. Several geometric design features including average segment length of arterial, number of lanes, presence of non-motorized lanes, number of access points, and commercial land use, were positively related to crash frequencies. Copyright © 2015 Elsevier Ltd. All rights reserved.
1994-01-01
Dosimetry : Analysis of dosimetry in two dewar/liquid nitrogen systems. TIME Estimate: One hour for setup, irradiation and TLD reading/analysis. IV...point indicates both electron and hole trapping at the boundary ........................ 12 3.3 Relationship between current and dose for irradiated...peak value. Carriers are collected across the vertical junction within a diffusion length. Since the electron diffusion length is much larger than for
Infant Growth in Length Follows Prolonged Sleep and Increased Naps
Lampl, Michelle; Johnson, Michael L.
2011-01-01
Study Objectives: The mechanisms underlying infant sleep irregularity are unknown. This study tests the hypothesis that sleep and episodic (saltatory) growth in infant length are temporally coupled processes. Study design: Daily parental diaries continuously recorded sleep onset and awakening for 23 infants (14 females) over 4-17 months (n = 5798 daily records). Multiple model-independent methods compared day-to-day sleep patterns and saltatory length growth. Measurements and Results: Approximate entropy (ApEn) quantified temporal irregularity in infant sleep patterns; breastfeeding and infant sex explained 44% of inter-individual variance (P = 0.001). Random effects mixed-model regression identified that saltatory length growth was associated with increased total daily sleep hours (P < 0.001) and number of sleep bouts (P = 0.001), with breastfeeding, infant sex, and age as covariates. Infant size and illness onset were non-contributory. CLUSTER analysis identified peaks in individual sleep of 4.5 more h and/or 3 more naps per day, compared to intervening intervals, that were non-randomly concordant with saltatory length growth for all individuals (P < 0.05), with a time lag of 0-4 days. Subject-specific probabilities of a growth saltation associated with sleep included a median odds ratio of 1.20 for each additional hour (n = 8, 95% CI 1.15 to 1.29) and 1.43 for each additional sleep bout (n = 12, 95% CI 1.21-2.03). Increased sleep bout duration predicted weight (P < 0.001) and abdominal skinfold accrual (P = 0.05) contingent on length growth, and truncal adiposity independent of growth (P < 0.001). Conclusions: Sleeping and length growth are temporally related biological processes, suggesting an integrated anabolic system. Infant behavioral state changes may reflect biological mechanisms underlying the timing and control of human growth. Citation: Lampl M; Johnson ML. Infant growth in length follows prolonged sleep and increased naps. SLEEP 2011;34(5):641-650. PMID:21532958
Poplawsky, Alexander John; Fukuda, Mitsuhiro; Kang, Bok-Man; Kim, Jae Hwan; Suh, Minah; Kim, Seong-Gi
2017-08-16
Contrast-enhanced cerebral blood volume-weighted (CBVw) fMRI response peaks are specific to the layer of evoked synaptic activity (Poplawsky et al., 2015), but the spatial resolution limit of CBVw fMRI is unknown. In this study, we measured the laminar spread of the CBVw fMRI evoked response in the external plexiform layer (EPL, 265 ± 65 μm anatomical thickness, mean ± SD, n = 30 locations from 5 rats) of the rat olfactory bulb during electrical stimulation of the lateral olfactory tract and examined its potential vascular source. First, we obtained the evoked CBVw fMRI responses with a 55 × 55 μm 2 in-plane resolution and a 500-μm thickness at 9.4 T, and found that the fMRI signal peaked predominantly in the inner half of EPL (136 ± 54 μm anatomical thickness). The mean full-width at half-maximum of these fMRI peaks was 347 ± 102 μm and the functional spread was approximately 100 or 200 μm when the effects of the laminar thicknesses of EPL or inner EPL were removed, respectively. Second, we visualized the vascular architecture of EPL from a different rat using a Clear Lipid-exchanged Anatomically Rigid Imaging/immunostaining-compatible Tissue hYdrogel (CLARITY)-based tissue preparation method and confocal microscopy. Microvascular segments with an outer diameter of <11 μm accounted for 64.3% of the total vascular volume within EPL and had a mean segment length of 55 ± 40 μm (n = 472). Additionally, vessels that crossed the EPL border had a mean segment length outside of EPL equal to 73 ± 61 μm (n = 28), which is comparable to half of the functional spread (50-100 μm). Therefore, we conclude that dilation of these microvessels, including capillaries, likely dominate the CBVw fMRI response and that the biological limit of the fMRI spatial resolution is approximately the average length of 1-2 microvessel segments, which may be sufficient for examining sublaminar circuits. Copyright © 2017 Elsevier Inc. All rights reserved.
On the Quality of Point-Clouds Derived from Sfm-Photogrammetry Applied to UAS Imagery
NASA Astrophysics Data System (ADS)
Carbonneau, P.; James, T.
2014-12-01
Structure from Motion photogrammetry (SfM-photogrammetry) recently appeared in environmental sciences as an impressive tool allowing for the creation of topographic data from unstructured imagery. Several authors have tested the performance of SfM-photogrammetry vs that of TLS or dGPS. Whilst the initial results were very promising, there is currently a growing awareness that systematic deformations occur in DEMs and point-clouds derived from SfM-photogrammetry. Notably, some authors have identified a systematic doming manifest as an increasing error vs distance to the model centre. Simulation studies have confirmed that this error is due to errors in the calibration of camera distortions. This work aims to further investigate these effects in the presence of real data. We start with a dataset of 220 images acquired from a sUAS. After obtaining an initial self-calibration of the camera lens with Agisoft Photoscan, our method consists in applying systematic perturbations to 2 key lens parameters: Focal length and the k1 distortion parameter. For each perturbation, a point-cloud was produced and compared to LiDAR data. After deriving the mean and standard deviation of the error residuals (ɛ), a 2nd order polynomial surface was fitted to the errors point-cloud and the peak ɛ defined as the mathematical extrema of this surface. The results are presented in figure 1. This figure shows that lens perturbations can induce a range of errors with systematic behaviours. Peak ɛ is primarily controlled by K1 with a secondary control exerted by the focal length. These results allow us to state that: To limit the peak ɛ to 10cm, the K1 parameter must be calibrated to within 0.00025 and the focal length to within 2.5 pixels (≈10 µm). This level of calibration accuracy can only be achieved with proper design of image acquisition and control network geometry. Our main point is therefore that SfM is not a bypass to a rigorous and well-informed photogrammetric approach. Users of SfM-photogrammetry will still require basic training and knowledge in the fundamentals of photogrammetry. This is especially true for applications where very small topographic changes need to be detected or where gradient-sensitive processes need to be modelled.
Extension of filament propagation in water with Bessel-Gaussian beams
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kaya, G.; Sayrac, M.; Boran, Y.
We experimentally studied intense femtosecond pulse filamentation and propagation in water for Bessel-Gaussian beams with different numbers of radial modal lobes. The transverse modes of the incident Bessel-Gaussian beam were created from a Gaussian beam of a Ti:sapphire laser system by using computer generated hologram techniques. We found that filament propagation length increased with increasing number of lobes under the conditions of the same peak intensity, pulse duration, and the size of the central peak of the incident beam, suggesting that the radial modal lobes may serve as an energy reservoir for the filaments formed by the central intensity peak.
Chen, Jun; Yu, Peng; Stenger, John; Hocevar, Moïra; Car, Diana; Plissard, Sébastien R.; Bakkers, Erik P. A. M.; Stanescu, Tudor D.; Frolov, Sergey M.
2017-01-01
Topological superconductivity is an exotic state of matter characterized by spinless p-wave Cooper pairing of electrons and by Majorana zero modes at the edges. The first signature of topological superconductivity is a robust zero-bias peak in tunneling conductance. We perform tunneling experiments on semiconductor nanowires (InSb) coupled to superconductors (NbTiN) and establish the zero-bias peak phase in the space of gate voltage and external magnetic field. Our findings are consistent with calculations for a finite-length topological nanowire and provide means for Majorana manipulation as required for braiding and topological quantum bits. PMID:28913432
NASA Astrophysics Data System (ADS)
Jagt, Thyrza; Breedveld, Sebastiaan; van de Water, Steven; Heijmen, Ben; Hoogeman, Mischa
2017-06-01
Proton therapy is very sensitive to daily density changes along the pencil beam paths. The purpose of this study is to develop and evaluate an automated method for adaptation of IMPT plans to compensate for these daily tissue density variations. A two-step restoration method for ‘densities-of-the-day’ was created: (1) restoration of spot positions (Bragg peaks) by adapting the energy of each pencil beam to the new water equivalent path length; and (2) re-optimization of pencil beam weights by minimizing the dosimetric difference with the planned dose distribution, using a fast and exact quadratic solver. The method was developed and evaluated using 8-10 repeat CT scans of 10 prostate cancer patients. Experiments demonstrated that giving a high weight to the PTV in the re-optimization resulted in clinically acceptable restorations. For all scans we obtained V 95% ⩾ 98% and V 107% ⩽ 2%. For the bladder, the differences between the restored and the intended treatment plan were below +2 Gy and +2%-point. The rectum differences were below +2 Gy and +2%-point for 90% of the scans. In the remaining scans the rectum was filled with air, which partly overlapped with the PTV. The air cavity distorted the Bragg peak resulting in less favorable rectum doses.
Bojesen, Stig E; Pooley, Karen A; Johnatty, Sharon E; Beesley, Jonathan; Michailidou, Kyriaki; Tyrer, Jonathan P; Edwards, Stacey L; Pickett, Hilda A; Shen, Howard C; Smart, Chanel E; Hillman, Kristine M; Mai, Phuong L; Lawrenson, Kate; Stutz, Michael D; Lu, Yi; Karevan, Rod; Woods, Nicholas; Johnston, Rebecca L; French, Juliet D; Chen, Xiaoqing; Weischer, Maren; Nielsen, Sune F; Maranian, Melanie J; Ghoussaini, Maya; Ahmed, Shahana; Baynes, Caroline; Bolla, Manjeet K; Wang, Qin; Dennis, Joe; McGuffog, Lesley; Barrowdale, Daniel; Lee, Andrew; Healey, Sue; Lush, Michael; Tessier, Daniel C; Vincent, Daniel; Bacot, Françis; Vergote, Ignace; Lambrechts, Sandrina; Despierre, Evelyn; Risch, Harvey A; González-Neira, Anna; Rossing, Mary Anne; Pita, Guillermo; Doherty, Jennifer A; Álvarez, Nuria; Larson, Melissa C; Fridley, Brooke L; Schoof, Nils; Chang-Claude, Jenny; Cicek, Mine S; Peto, Julian; Kalli, Kimberly R; Broeks, Annegien; Armasu, Sebastian M; Schmidt, Marjanka K; Braaf, Linde M; Winterhoff, Boris; Nevanlinna, Heli; Konecny, Gottfried E; Lambrechts, Diether; Rogmann, Lisa; Guénel, Pascal; Teoman, Attila; Milne, Roger L; Garcia, Joaquin J; Cox, Angela; Shridhar, Vijayalakshmi; Burwinkel, Barbara; Marme, Frederik; Hein, Rebecca; Sawyer, Elinor J; Haiman, Christopher A; Wang-Gohrke, Shan; Andrulis, Irene L; Moysich, Kirsten B; Hopper, John L; Odunsi, Kunle; Lindblom, Annika; Giles, Graham G; Brenner, Hermann; Simard, Jacques; Lurie, Galina; Fasching, Peter A; Carney, Michael E; Radice, Paolo; Wilkens, Lynne R; Swerdlow, Anthony; Goodman, Marc T; Brauch, Hiltrud; García-Closas, Montserrat; Hillemanns, Peter; Winqvist, Robert; Dürst, Matthias; Devilee, Peter; Runnebaum, Ingo; Jakubowska, Anna; Lubinski, Jan; Mannermaa, Arto; Butzow, Ralf; Bogdanova, Natalia V; Dörk, Thilo; Pelttari, Liisa M; Zheng, Wei; Leminen, Arto; Anton-Culver, Hoda; Bunker, Clareann H; Kristensen, Vessela; Ness, Roberta B; Muir, Kenneth; Edwards, Robert; Meindl, Alfons; Heitz, Florian; Matsuo, Keitaro; du Bois, Andreas; Wu, Anna H; Harter, Philipp; Teo, Soo-Hwang; Schwaab, Ira; Shu, Xiao-Ou; Blot, William; Hosono, Satoyo; Kang, Daehee; Nakanishi, Toru; Hartman, Mikael; Yatabe, Yasushi; Hamann, Ute; Karlan, Beth Y; Sangrajrang, Suleeporn; Kjaer, Susanne Krüger; Gaborieau, Valerie; Jensen, Allan; Eccles, Diana; Høgdall, Estrid; Shen, Chen-Yang; Brown, Judith; Woo, Yin Ling; Shah, Mitul; Azmi, Mat Adenan Noor; Luben, Robert; Omar, Siti Zawiah; Czene, Kamila; Vierkant, Robert A; Nordestgaard, Børge G; Flyger, Henrik; Vachon, Celine; Olson, Janet E; Wang, Xianshu; Levine, Douglas A; Rudolph, Anja; Weber, Rachel Palmieri; Flesch-Janys, Dieter; Iversen, Edwin; Nickels, Stefan; Schildkraut, Joellen M; Silva, Isabel Dos Santos; Cramer, Daniel W; Gibson, Lorna; Terry, Kathryn L; Fletcher, Olivia; Vitonis, Allison F; van der Schoot, C Ellen; Poole, Elizabeth M; Hogervorst, Frans B L; Tworoger, Shelley S; Liu, Jianjun; Bandera, Elisa V; Li, Jingmei; Olson, Sara H; Humphreys, Keith; Orlow, Irene; Blomqvist, Carl; Rodriguez-Rodriguez, Lorna; Aittomäki, Kristiina; Salvesen, Helga B; Muranen, Taru A; Wik, Elisabeth; Brouwers, Barbara; Krakstad, Camilla; Wauters, Els; Halle, Mari K; Wildiers, Hans; Kiemeney, Lambertus A; Mulot, Claire; Aben, Katja K; Laurent-Puig, Pierre; van Altena, Anne M; Truong, Thérèse; Massuger, Leon F A G; Benitez, Javier; Pejovic, Tanja; Perez, Jose Ignacio Arias; Hoatlin, Maureen; Zamora, M Pilar; Cook, Linda S; Balasubramanian, Sabapathy P; Kelemen, Linda E; Schneeweiss, Andreas; Le, Nhu D; Sohn, Christof; Brooks-Wilson, Angela; Tomlinson, Ian; Kerin, Michael J; Miller, Nicola; Cybulski, Cezary; Henderson, Brian E; Menkiszak, Janusz; Schumacher, Fredrick; Wentzensen, Nicolas; Marchand, Loic Le; Yang, Hannah P; Mulligan, Anna Marie; Glendon, Gord; Engelholm, Svend Aage; Knight, Julia A; Høgdall, Claus K; Apicella, Carmel; Gore, Martin; Tsimiklis, Helen; Song, Honglin; Southey, Melissa C; Jager, Agnes; van den Ouweland, Ans M W; Brown, Robert; Martens, John W M; Flanagan, James M; Kriege, Mieke; Paul, James; Margolin, Sara; Siddiqui, Nadeem; Severi, Gianluca; Whittemore, Alice S; Baglietto, Laura; McGuire, Valerie; Stegmaier, Christa; Sieh, Weiva; Müller, Heiko; Arndt, Volker; Labrèche, France; Gao, Yu-Tang; Goldberg, Mark S; Yang, Gong; Dumont, Martine; McLaughlin, John R; Hartmann, Arndt; Ekici, Arif B; Beckmann, Matthias W; Phelan, Catherine M; Lux, Michael P; Permuth-Wey, Jenny; Peissel, Bernard; Sellers, Thomas A; Ficarazzi, Filomena; Barile, Monica; Ziogas, Argyrios; Ashworth, Alan; Gentry-Maharaj, Aleksandra; Jones, Michael; Ramus, Susan J; Orr, Nick; Menon, Usha; Pearce, Celeste L; Brüning, Thomas; Pike, Malcolm C; Ko, Yon-Dschun; Lissowska, Jolanta; Figueroa, Jonine; Kupryjanczyk, Jolanta; Chanock, Stephen J; Dansonka-Mieszkowska, Agnieszka; Jukkola-Vuorinen, Arja; Rzepecka, Iwona K; Pylkäs, Katri; Bidzinski, Mariusz; Kauppila, Saila; Hollestelle, Antoinette; Seynaeve, Caroline; Tollenaar, Rob A E M; Durda, Katarzyna; Jaworska, Katarzyna; Hartikainen, Jaana M; Kosma, Veli-Matti; Kataja, Vesa; Antonenkova, Natalia N; Long, Jirong; Shrubsole, Martha; Deming-Halverson, Sandra; Lophatananon, Artitaya; Siriwanarangsan, Pornthep; Stewart-Brown, Sarah; Ditsch, Nina; Lichtner, Peter; Schmutzler, Rita K; Ito, Hidemi; Iwata, Hiroji; Tajima, Kazuo; Tseng, Chiu-Chen; Stram, Daniel O; van den Berg, David; Yip, Cheng Har; Ikram, M Kamran; Teh, Yew-Ching; Cai, Hui; Lu, Wei; Signorello, Lisa B; Cai, Qiuyin; Noh, Dong-Young; Yoo, Keun-Young; Miao, Hui; Iau, Philip Tsau-Choong; Teo, Yik Ying; McKay, James; Shapiro, Charles; Ademuyiwa, Foluso; Fountzilas, George; Hsiung, Chia-Ni; Yu, Jyh-Cherng; Hou, Ming-Feng; Healey, Catherine S; Luccarini, Craig; Peock, Susan; Stoppa-Lyonnet, Dominique; Peterlongo, Paolo; Rebbeck, Timothy R; Piedmonte, Marion; Singer, Christian F; Friedman, Eitan; Thomassen, Mads; Offit, Kenneth; Hansen, Thomas V O; Neuhausen, Susan L; Szabo, Csilla I; Blanco, Ignacio; Garber, Judy; Narod, Steven A; Weitzel, Jeffrey N; Montagna, Marco; Olah, Edith; Godwin, Andrew K; Yannoukakos, Drakoulis; Goldgar, David E; Caldes, Trinidad; Imyanitov, Evgeny N; Tihomirova, Laima; Arun, Banu K; Campbell, Ian; Mensenkamp, Arjen R; van Asperen, Christi J; van Roozendaal, Kees E P; Meijers-Heijboer, Hanne; Collée, J Margriet; Oosterwijk, Jan C; Hooning, Maartje J; Rookus, Matti A; van der Luijt, Rob B; van Os, Theo A M; Evans, D Gareth; Frost, Debra; Fineberg, Elena; Barwell, Julian; Walker, Lisa; Kennedy, M John; Platte, Radka; Davidson, Rosemarie; Ellis, Steve D; Cole, Trevor; Paillerets, Brigitte Bressac-de; Buecher, Bruno; Damiola, Francesca; Faivre, Laurence; Frenay, Marc; Sinilnikova, Olga M; Caron, Olivier; Giraud, Sophie; Mazoyer, Sylvie; Bonadona, Valérie; Caux-Moncoutier, Virginie; Toloczko-Grabarek, Aleksandra; Gronwald, Jacek; Byrski, Tomasz; Spurdle, Amanda B; Bonanni, Bernardo; Zaffaroni, Daniela; Giannini, Giuseppe; Bernard, Loris; Dolcetti, Riccardo; Manoukian, Siranoush; Arnold, Norbert; Engel, Christoph; Deissler, Helmut; Rhiem, Kerstin; Niederacher, Dieter; Plendl, Hansjoerg; Sutter, Christian; Wappenschmidt, Barbara; Borg, Åke; Melin, Beatrice; Rantala, Johanna; Soller, Maria; Nathanson, Katherine L; Domchek, Susan M; Rodriguez, Gustavo C; Salani, Ritu; Kaulich, Daphne Gschwantler; Tea, Muy-Kheng; Paluch, Shani Shimon; Laitman, Yael; Skytte, Anne-Bine; Kruse, Torben A; Jensen, Uffe Birk; Robson, Mark; Gerdes, Anne-Marie; Ejlertsen, Bent; Foretova, Lenka; Savage, Sharon A; Lester, Jenny; Soucy, Penny; Kuchenbaecker, Karoline B; Olswold, Curtis; Cunningham, Julie M; Slager, Susan; Pankratz, Vernon S; Dicks, Ed; Lakhani, Sunil R; Couch, Fergus J; Hall, Per; Monteiro, Alvaro N A; Gayther, Simon A; Pharoah, Paul D P; Reddel, Roger R; Goode, Ellen L; Greene, Mark H; Easton, Douglas F; Berchuck, Andrew; Antoniou, Antonis C; Chenevix-Trench, Georgia; Dunning, Alison M
2013-01-01
TERT-locus single nucleotide polymorphisms (SNPs) and leucocyte telomere measures are reportedly associated with risks of multiple cancers. Using the iCOGs chip, we analysed ~480 TERT-locus SNPs in breast (n=103,991), ovarian (n=39,774) and BRCA1 mutation carrier (11,705) cancer cases and controls. 53,724 participants have leucocyte telomere measures. Most associations cluster into three independent peaks. Peak 1 SNP rs2736108 minor allele associates with longer telomeres (P=5.8×10−7), reduced estrogen receptor negative (ER-negative) (P=1.0×10−8) and BRCA1 mutation carrier (P=1.1×10−5) breast cancer risks, and altered promoter-assay signal. Peak 2 SNP rs7705526 minor allele associates with longer telomeres (P=2.3×10−14), increased low malignant potential ovarian cancer risk (P=1.3×10−15) and increased promoter activity. Peak 3 SNPs rs10069690 and rs2242652 minor alleles increase ER-negative (P=1.2×10−12) and BRCA1 mutation carrier (P=1.6×10−14) breast and invasive ovarian (P=1.3×10−11) cancer risks, but not via altered telomere length. The cancer-risk alleles of rs2242652 and rs10069690 respectively increase silencing and generate a truncated TERT splice-variant. PMID:23535731
Intra-operatively measured spastic semimembranosus forces of children with cerebral palsy.
Yucesoy, Can A; Temelli, Yener; Ateş, Filiz
2017-10-01
The knee kept forcibly in a flexed position is typical in cerebral palsy. Using a benchmark, we investigate intra-operatively if peak spastic hamstring force is measured in flexed knee positions. This tests the assumed shift of optimal length due to adaptation of spastic muscle and a decreasing force trend towards extension. Previously we measured spastic gracilis (GRA) and semitendinosus (ST) forces. Presently, we studied spastic semimembranosus (SM) and tested the following hypotheses: spastic SM forces are (1) high in flexed and (2) low in extended positions. We compared the data to those of GRA and ST to test (3) if percentages of peak force produced in flexed positions are different. During muscle lengthening surgery of 8 CP patients (9years, 4months; GMFCS levels=II-IV; limbs tested=13) isometric SM forces were measured from flexion (120°) to full extension (0°). Spastic SM forces were low in flexed knee positions (only 4.2% (3.4%) and 10.7% (9.7%) of peak force at KA=120° and KA=90° respectively, indicating less force production compared to the GRA or ST) and high in extended knee positions (even 100% of peak force at KA=0°). This indicates an absence of strong evidence for a shift of optimal muscle length of SM towards flexion. Copyright © 2017 Elsevier Ltd. All rights reserved.
Lobarinas, Edward; Scott, Ryan; Spankovich, Christopher; Le Prell, Colleen G
2016-01-01
Firearm discharges produce hazardous levels of impulse noise that can lead to permanent hearing loss. In the present study, we evaluated the effects of suppression, ammunition, and barrel length on AR-15 rifles. Sound levels were measured left/right of a user's head, and 1-m left of the muzzle, per MIL-STD-1474-D, under both unsuppressed and suppressed conditions. Nine commercially available AR-15 rifles and 14 suppressors were used. Suppressors significantly decreased peak dB SPL at the 1-m location and the left ear location. However, under most rifle/ammunition conditions, levels remained above 140 dB peak SPL near a user's right ear. In a subset of conditions, subsonic ammunition produced values near or below 140 dB peak SPL. Overall suppression ranged from 7-32 dB across conditions. These data indicate that (1) suppressors reduce discharge levels to 140 dB peak SPL or below in only a subset of AR-15 conditions, (2) shorter barrel length and use of muzzle brake devices can substantially increase exposure level for the user, and (3) there are significant left/right ear sound pressure differences under suppressed conditions as a function of the AR-15 direct impingement design that must be considered during sound measurements to fully evaluate overall efficacy.
NASA Astrophysics Data System (ADS)
Jung, Il-Chan; Kang, Deok-Gu; De Cooman, Bruno C.
2014-04-01
The simultaneous presence of interstitial solutes and dislocations in an ultra-low carbon bake-hardenable steel gives rise to two characteristic peaks in the internal friction (IF) spectrum: the dislocation-enhanced Snoek peak and the Snoek-Kê-Köster peak. These IF peaks were used to study the dislocation structure developed by the pre-straining and the static strain aging effect of C during the bake-hardening process. A Ti-stabilized interstitial-free steel was used to ascertain the absence of a γ-peak in the IF spectrum of the deformed ultra-low carbon steel. The analysis of the IF data shows clearly that the bake-hardening effect in ultra-low carbon steel is entirely due to atmosphere formation, with the dislocation segment length being the main parameter affecting the IF peak amplitude. Recovery annealing experiments showed that the rearrangement of the dislocation structure lead to the elimination of the C atmosphere.
Short, N J; Norval, R A
1981-02-01
Rhipicephalus appendiculatus passes through one generation per annum in the highveld of Zimbabwe, Rhodesia and shows a well-defined pattern of seasonal activity. Peak adult activity occurs in the rainy season, whereas peak larval and nymphal activity occurs in the dry season. Adult activity is regulated by the combined influences of temperature, humidity, and day length. Climatic factors have little or no direct influence on the activity of larvae and nymphs. The occurrence of the larval and nymphal activity peaks is determined by the timing of the adult activity peak and the duration of the preceeding developmental periods, which are temperature dependent. In the early rainy season, unfed adults climb to the tips of the grass and enter a period of quiescence prior to becoming active.
Alp, Murat; Cucinotta, Francis A.
2017-01-01
Changes to cognition, including memory, following radiation exposure are a concern for cosmic ray exposures to astronauts and in Hadron therapy with proton and heavy ion beams. The purpose of the present work is to develop computational methods to evaluate microscopic energy deposition (ED) in volumes representative of neuron cell structures, including segments of dendrites and spines, using a stochastic track structure model. A challenge for biophysical models of neuronal damage is the large sizes (>100 μm) and variability in volumes of possible dendritic segments and pre-synaptic elements (spines and filopodia). We consider cylindrical and spherical microscopic volumes of varying geometric parameters and aspect ratios from 0.5 to 5 irradiated by protons, and 3He and 12C particles at energies corresponding to a distance of 1 cm to the Bragg peak, which represent particles of interest in Hadron therapy as well as space radiation exposure. We investigate the optimal axis length of dendritic segments to evaluate microscopic ED and hit probabilities along the dendritic branches at a given macroscopic dose. Because of large computation times to analyze ED in volumes of varying sizes, we developed an analytical method to find the mean primary dose in spheres that can guide numerical methods to find the primary dose distribution for cylinders. Considering cylindrical segments of varying aspect ratio at constant volume, we assess the chord length distribution, mean number of hits and ED profiles by primary particles and secondary electrons (δ-rays). For biophysical modeling applications, segments on dendritic branches are proposed to have equal diameters and axes lengths along the varying diameter of a dendritic branch. PMID:28554507
NASA Astrophysics Data System (ADS)
Alp, Murat; Cucinotta, Francis A.
2017-05-01
Changes to cognition, including memory, following radiation exposure are a concern for cosmic ray exposures to astronauts and in Hadron therapy with proton and heavy ion beams. The purpose of the present work is to develop computational methods to evaluate microscopic energy deposition (ED) in volumes representative of neuron cell structures, including segments of dendrites and spines, using a stochastic track structure model. A challenge for biophysical models of neuronal damage is the large sizes (> 100 μm) and variability in volumes of possible dendritic segments and pre-synaptic elements (spines and filopodia). We consider cylindrical and spherical microscopic volumes of varying geometric parameters and aspect ratios from 0.5 to 5 irradiated by protons, and 3He and 12C particles at energies corresponding to a distance of 1 cm to the Bragg peak, which represent particles of interest in Hadron therapy as well as space radiation exposure. We investigate the optimal axis length of dendritic segments to evaluate microscopic ED and hit probabilities along the dendritic branches at a given macroscopic dose. Because of large computation times to analyze ED in volumes of varying sizes, we developed an analytical method to find the mean primary dose in spheres that can guide numerical methods to find the primary dose distribution for cylinders. Considering cylindrical segments of varying aspect ratio at constant volume, we assess the chord length distribution, mean number of hits and ED profiles by primary particles and secondary electrons (δ-rays). For biophysical modeling applications, segments on dendritic branches are proposed to have equal diameters and axes lengths along the varying diameter of a dendritic branch.
Alp, Murat; Cucinotta, Francis A
2017-05-01
Changes to cognition, including memory, following radiation exposure are a concern for cosmic ray exposures to astronauts and in Hadron therapy with proton and heavy ion beams. The purpose of the present work is to develop computational methods to evaluate microscopic energy deposition (ED) in volumes representative of neuron cell structures, including segments of dendrites and spines, using a stochastic track structure model. A challenge for biophysical models of neuronal damage is the large sizes (> 100µm) and variability in volumes of possible dendritic segments and pre-synaptic elements (spines and filopodia). We consider cylindrical and spherical microscopic volumes of varying geometric parameters and aspect ratios from 0.5 to 5 irradiated by protons, and 3 He and 12 C particles at energies corresponding to a distance of 1cm to the Bragg peak, which represent particles of interest in Hadron therapy as well as space radiation exposure. We investigate the optimal axis length of dendritic segments to evaluate microscopic ED and hit probabilities along the dendritic branches at a given macroscopic dose. Because of large computation times to analyze ED in volumes of varying sizes, we developed an analytical method to find the mean primary dose in spheres that can guide numerical methods to find the primary dose distribution for cylinders. Considering cylindrical segments of varying aspect ratio at constant volume, we assess the chord length distribution, mean number of hits and ED profiles by primary particles and secondary electrons (δ-rays). For biophysical modeling applications, segments on dendritic branches are proposed to have equal diameters and axes lengths along the varying diameter of a dendritic branch. Copyright © 2017. Published by Elsevier Ltd.
Comparison of Peak-Flow Estimation Methods for Small Drainage Basins in Maine
Hodgkins, Glenn A.; Hebson, Charles; Lombard, Pamela J.; Mann, Alexander
2007-01-01
Understanding the accuracy of commonly used methods for estimating peak streamflows is important because the designs of bridges, culverts, and other river structures are based on these flows. Different methods for estimating peak streamflows were analyzed for small drainage basins in Maine. For the smallest basins, with drainage areas of 0.2 to 1.0 square mile, nine peak streamflows from actual rainfall events at four crest-stage gaging stations were modeled by the Rational Method and the Natural Resource Conservation Service TR-20 method and compared to observed peak flows. The Rational Method had a root mean square error (RMSE) of -69.7 to 230 percent (which means that approximately two thirds of the modeled flows were within -69.7 to 230 percent of the observed flows). The TR-20 method had an RMSE of -98.0 to 5,010 percent. Both the Rational Method and TR-20 underestimated the observed flows in most cases. For small basins, with drainage areas of 1.0 to 10 square miles, modeled peak flows were compared to observed statistical peak flows with return periods of 2, 50, and 100 years for 17 streams in Maine and adjoining parts of New Hampshire. Peak flows were modeled by the Rational Method, the Natural Resources Conservation Service TR-20 method, U.S. Geological Survey regression equations, and the Probabilistic Rational Method. The regression equations were the most accurate method of computing peak flows in Maine for streams with drainage areas of 1.0 to 10 square miles with an RMSE of -34.3 to 52.2 percent for 50-year peak flows. The Probabilistic Rational Method was the next most accurate method (-38.5 to 62.6 percent). The Rational Method (-56.1 to 128 percent) and particularly the TR-20 method (-76.4 to 323 percent) had much larger errors. Both the TR-20 and regression methods had similar numbers of underpredictions and overpredictions. The Rational Method overpredicted most peak flows and the Probabilistic Rational Method tended to overpredict peak flows from the smaller (less than 5 square miles) drainage basins and underpredict peak flows from larger drainage basins. The results of this study are consistent with the most comprehensive analysis of observed and modeled peak streamflows in the United States, which analyzed statistical peak flows from 70 drainage basins in the Midwest and the Northwest.
NASA Astrophysics Data System (ADS)
Wang, Min; Zhang, Huijie; Zhang, Jingbao; Zhang, Xiao; Yang, Lei
2014-05-01
Friction stir lap welding of 7B04 aluminum alloy was conducted in the present paper, and the effect of pin length on hook size and joint properties was investigated in detail. It is found that for each given set of process parameters, the size of hook defect on the advancing side shows an "M" type evolution trend as the pin length is increased. The affecting characteristics of pin length on joint properties are dependent on the heat input levels. When the heat input is low, the fracture strength is firstly increased to a peak value and then shows a decrease. When the heat input is relatively high, the evolution trend of fracture strength tends to exhibit a "W" type with increasing the pin length.
NASA Astrophysics Data System (ADS)
Berkovits, Richard
2018-03-01
The properties of the low-lying eigenvalues of the entanglement Hamiltonian and their relation to the localization length of a disordered interacting one-dimensional many-particle system are studied. The average of the first entanglement Hamiltonian level spacing is proportional to the ground-state localization length and shows the same dependence on the disorder and interaction strength as the localization length. This is the result of the fact that entanglement is limited to distances of order of the localization length. The distribution of the first entanglement level spacing shows a Gaussian-type behavior as expected for level spacings much larger than the disorder broadening. For weakly disordered systems (localization length larger than sample length), the distribution shows an additional peak at low-level spacings. This stems from rare regions in some samples which exhibit metalliclike behavior of large entanglement and large particle-number fluctuations. These intermediate microemulsion metallic regions embedded in the insulating phase are discussed.
Asquith, William H.; Cleveland, Theodore G.; Roussel, Meghan C.
2011-01-01
Estimates of peak and time of peak streamflow for small watersheds (less than about 640 acres) in a suburban to urban, low-slope setting are needed for drainage design that is cost-effective and risk-mitigated. During 2007-10, the U.S. Geological Survey (USGS), in cooperation with the Harris County Flood Control District and the Texas Department of Transportation, developed a method to estimate peak and time of peak streamflow from excess rainfall for 10- to 640-acre watersheds in the Houston, Texas, metropolitan area. To develop the method, 24 watersheds in the study area with drainage areas less than about 3.5 square miles (2,240 acres) and with concomitant rainfall and runoff data were selected. The method is based on conjunctive analysis of rainfall and runoff data in the context of the unit hydrograph method and the rational method. For the unit hydrograph analysis, a gamma distribution model of unit hydrograph shape (a gamma unit hydrograph) was chosen and parameters estimated through matching of modeled peak and time of peak streamflow to observed values on a storm-by-storm basis. Watershed mean or watershed-specific values of peak and time to peak ("time to peak" is a parameter of the gamma unit hydrograph and is distinct from "time of peak") of the gamma unit hydrograph were computed. Two regression equations to estimate peak and time to peak of the gamma unit hydrograph that are based on watershed characteristics of drainage area and basin-development factor (BDF) were developed. For the rational method analysis, a lag time (time-R), volumetric runoff coefficient, and runoff coefficient were computed on a storm-by-storm basis. Watershed-specific values of these three metrics were computed. A regression equation to estimate time-R based on drainage area and BDF was developed. Overall arithmetic means of volumetric runoff coefficient (0.41 dimensionless) and runoff coefficient (0.25 dimensionless) for the 24 watersheds were used to express the rational method in terms of excess rainfall (the excess rational method). Both the unit hydrograph method and excess rational method are shown to provide similar estimates of peak and time of peak streamflow. The results from the two methods can be combined by using arithmetic means. A nomograph is provided that shows the respective relations between the arithmetic-mean peak and time of peak streamflow to drainage areas ranging from 10 to 640 acres. The nomograph also shows the respective relations for selected BDF ranging from undeveloped to fully developed conditions. The nomograph represents the peak streamflow for 1 inch of excess rainfall based on drainage area and BDF; the peak streamflow for design storms from the nomograph can be multiplied by the excess rainfall to estimate peak streamflow. Time of peak streamflow is readily obtained from the nomograph. Therefore, given excess rainfall values derived from watershed-loss models, which are beyond the scope of this report, the nomograph represents a method for estimating peak and time of peak streamflow for applicable watersheds in the Houston metropolitan area. Lastly, analysis of the relative influence of BDF on peak streamflow is provided, and the results indicate a 0:04log10 cubic feet per second change of peak streamflow per positive unit of change in BDF. This relative change can be used to adjust peak streamflow from the method or other hydrologic methods for a given BDF to other BDF values; example computations are provided.
NASA Technical Reports Server (NTRS)
Pineda, Evan J.; Bednarcyk, Brett A.; Arnold, Steven M.; Waas, Anthony M.
2013-01-01
A mesh objective crack band model was implemented within the generalized method of cells micromechanics theory. This model was linked to a macroscale finite element model to predict post-peak strain softening in composite materials. Although a mesh objective theory was implemented at the microscale, it does not preclude pathological mesh dependence at the macroscale. To ensure mesh objectivity at both scales, the energy density and the energy release rate must be preserved identically across the two scales. This requires a consistent characteristic length or localization limiter. The effects of scaling (or not scaling) the dimensions of the microscale repeating unit cell (RUC), according to the macroscale element size, in a multiscale analysis was investigated using two examples. Additionally, the ramifications of the macroscale element shape, compared to the RUC, was studied.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dias, M F; Department of Radiation Oncology, Francis H. Burr Proton Therapy Center Massachusetts General Hospital; Seco, J
Purpose: Research in carbon imaging has been growing over the past years, as a way to increase treatment accuracy and patient positioning in carbon therapy. The purpose of this tool is to allow a fast and flexible way to generate CDRR data without the need to use Monte Carlo (MC) simulations. It can also be used to predict future clinically measured data. Methods: A python interface has been developed, which uses information from CT or 4DCT and thetreatment calibration curve to compute the Water Equivalent Path Length (WEPL) of carbon ions. A GPU based ray tracing algorithm computes the WEPLmore » of each individual carbon traveling through the CT voxels. A multiple peak detection method to estimate high contrast margin positioning has been implemented (described elsewhere). MC simulations have been used to simulate carbons depth dose curves in order to simulate the response of a range detector. Results: The tool allows the upload of CT or 4DCT images. The user has the possibility to selectphase/slice of interested as well as position, angle…). The WEPL is represented as a range detector which can be used to assess range dilution and multiple peak detection effects. The tool also provides knowledge of the minimum energy that should be considered for imaging purposes. The multiple peak detection method has been used in a lung tumor case, showing an accuracy of 1mm in determine the exact interface position. Conclusion: The tool offers an easy and fast way to simulate carbon imaging data. It can be used for educational and for clinical purposes, allowing the user to test beam energies and angles before real acquisition. An analysis add-on is being developed, where the used will have the opportunity to select different reconstruction methods and detector types (range or energy). Fundacao para a Ciencia e a Tecnologia (FCT), PhD Grant number SFRH/BD/85749/2012.« less
Costa, Fernanda das Neves; Vieira, Mariana Neves; Garrard, Ian; Hewitson, Peter; Jerz, Gerold; Leitão, Gilda Guimarães; Ignatova, Svetlana
2016-09-30
Countercurrent chromatography (CCC) is being widely used across the world for purification of various materials, especially in natural product research. The predictability of CCC scale-up has been successfully demonstrated using specially designed instruments of the same manufacturer. The reality is that the most of CCC users do not have access to such instruments and do not have enough experience to transfer methods from one CCC column to another. This unique study of three international teams is based on innovative approach to simplify the scale-up between different CCC machines using fractionation of Schinus terebinthifolius berries dichloromethane extract as a case study. The optimized separation methodology, recently developed by the authors (Part I), was repeatedly performed on CCC columns of different design available at most research laboratories across the world. Hexane - ethyl acetate - methanol - water (6:1:6:1, v/v/v/v) was used as solvent system with masticadienonic and 3β-masticadienolic acids as target compounds to monitor stationary phase retention and calculate peak resolution. It has been demonstrated that volumetric, linear and length scale-up transfer factors based on column characteristics can be directly applied to different i.d., volume and length columns independently on instrument make in an intra-apparatus scale-up and inter-apparatus method transfer. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Talamonti, James J.; Kay, Richard B.; Krebs, Danny J.
1996-05-01
A numerical model was developed to emulate the capabilities of systems performing noncontact absolute distance measurements. The model incorporates known methods to minimize signal processing and digital sampling errors and evaluates the accuracy limitations imposed by spectral peak isolation by using Hanning, Blackman, and Gaussian windows in the fast Fourier transform technique. We applied this model to the specific case of measuring the relative lengths of a compound Michelson interferometer. By processing computer-simulated data through our model, we project the ultimate precision for ideal data, and data containing AM-FM noise. The precision is shown to be limited by nonlinearities in the laser scan. absolute distance, interferometer.
An MDOE Investigation of Chevrons for Supersonic Jet Noise Reduction
NASA Technical Reports Server (NTRS)
Henderson, Brenda; Bridges, James
2010-01-01
The impact of chevron design on the noise radiated from heated, overexpanded, supersonic jets is presented. The experiments used faceted bi-conic convergent-divergent nozzles with design Mach numbers equal to 1.51 and 1.65. The purpose of the facets was to simulate divergent seals on a military style nozzle. The nozzle throat diameter was equal to 4.5 inches. Modern Design of Experiment (MDOE) techniques were used to investigate the impact of chevron penetration, length, and width on the resulting acoustic radiation. All chevron configurations used 12 chevrons to match the number of facets in the nozzle. Most chevron designs resulted in increased broadband shock noise relative to the baseline nozzle. In the peak jet noise direction, the optimum chevron design reduced peak sound pressure levels by 4 dB relative to the baseline nozzle. The penetration was the parameter having the greatest impact on radiated noise at all observation angles. While increasing chevron penetration decreased acoustic radiation in the peak jet noise direction, broadband shock noise was adversely impacted. Decreasing chevron length increased noise at most observation angles. The impact of chevron width on radiated noise depended on frequency and observation angle.
Power and energy dissipation in subsequent return strokes as predicted by a new return stroke model
NASA Technical Reports Server (NTRS)
Cooray, Vernon
1991-01-01
Recently, Cooray introduced a new return stroke model which is capable of predicting the temporal behavior of the return stroke current and the return stroke velocity as a function of the height along the return stroke channel. The authors employed this model to calculate the power and energy dissipation in subsequent return strokes. The results of these calculations are presented here. It was concluded that a large fraction of the total energy available for the dart leader-subsequent stroke process is dissipated in the dart leader stage. The peak power per unit length dissipated in a subsequent stroke channel element decreases with increasing height of that channel element from ground level. For a given channel element, the peak power dissipation increases with increasing current in that channel element. The peak electrical power dissipation in a typical subsequent return stroke is about 1.5 times 10(exp 11) W. The energy dissipation in a subsequent stroke increases with increasing current in the return stroke channel, and for a typical subsequent stroke, the energy dissipation per unit length is about 5.0 times 10(exp 3) J/m.
NASA Astrophysics Data System (ADS)
Li, L. B.
2017-01-01
The effect of matrix multicracking on the stress-strain hysteresis loops of cross-ply C/SiC ceramic-matrix composites (CMCs) under cyclic loading/unloading was investigated. When matrix multicracking and fiber/matrix interface debonding occur in the 0° plies, fiber slipping relative to the matrix in the debonded region of interface is the mainly reason for occurrence of the loops. The interfacial slip lengths, i.e., the debonded lengths of interface are determined, with consideration of matrix multicracking in the 90° and 0° plies, by using the fracture mechanics approach. The effects of peak stress, fiber volume content, fiber/matrix interfacial shear stress, and number of cycles on the hysteresis loops are analyzed. The stress-strain hysteresis loops of cross-ply C/SiC composites corresponding to different peak stresses and numbers of cycles are predicted.
A joint method to retrieve directional ocean wave spectra from SAR and wave spectrometer data
NASA Astrophysics Data System (ADS)
Ren, Lin; Yang, Jingsong; Zheng, Gang; Wang, Juan
2016-07-01
This paper proposes a joint method to simultaneously retrieve wave spectra at different scales from spaceborne Synthetic Aperture Radar (SAR) and wave spectrometer data. The method combines the output from the two different sensors to overcome retrieval limitations that occur in some sea states. The wave spectrometer sensitivity coefficient is estimated using an effective significant wave height (SWH), which is an average of SAR-derived and wave spectrometer-derived SWH. This averaging extends the area of the sea surface sampled by the nadir beam of the wave spectrometer to improve the accuracy of the estimated sensitivity coefficient in inhomogeneous sea states. Wave spectra are then retrieved from SAR data using wave spectrometer-derived spectra as first guess spectra to complement the short waves lost in SAR data retrieval. In addition, the problem of 180° ambiguity in retrieved spectra is overcome using SAR imaginary cross spectra. Simulated data were used to validate the joint method. The simulations demonstrated that retrieved wave parameters, including SWH, peak wave length (PWL), and peak wave direction (PWD), agree well with reference parameters. Collocated data from ENVISAT advanced SAR (ASAR), the airborne wave spectrometer STORM, the PHAROS buoy, and the European Centre for Medium-Range Weather Forecasting (ECMWF) were then used to verify the proposed method. Wave parameters retrieved from STORM and two ASAR images were compared to buoy and ECMWF wave data. Most of the retrieved parameters were comparable to reference parameters. The results of this study show that the proposed joint retrieval method could be a valuable complement to traditional methods used to retrieve directional ocean wave spectra, particularly in inhomogeneous sea states.
Study on peak shape fitting method in radon progeny measurement.
Yang, Jinmin; Zhang, Lei; Abdumomin, Kadir; Tang, Yushi; Guo, Qiuju
2015-11-01
Alpha spectrum measurement is one of the most important methods to measure radon progeny concentration in environment. However, the accuracy of this method is affected by the peak tailing due to the energy losses of alpha particles. This article presents a peak shape fitting method that can overcome the peak tailing problem in most situations. On a typical measured alpha spectrum curve, consecutive peaks overlap even their energies are not close to each other, and it is difficult to calculate the exact count of each peak. The peak shape fitting method uses combination of Gaussian and exponential functions, which can depict features of those peaks, to fit the measured curve. It can provide net counts of each peak explicitly, which was used in the Kerr method of calculation procedure for radon progeny concentration measurement. The results show that the fitting curve fits well with the measured curve, and the influence of the peak tailing is reduced. The method was further validated by the agreement between radon equilibrium equivalent concentration based on this method and the measured values of some commercial radon monitors, such as EQF3220 and WLx. In addition, this method improves the accuracy of individual radon progeny concentration measurement. Especially for the (218)Po peak, after eliminating the peak tailing influence, the calculated result of (218)Po concentration has been reduced by 21 %. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Moretto, P; Bisiaux, M; Lafortune, M A
2007-01-01
The purpose of this study was to determine if using similar walking velocities obtained from fractions of the Froude number (N(Fr)) and leg length can lead to kinematic and kinetic similarities and lower variability. Fifteen male subjects walked on a treadmill at 0.83 (VS(1)) and 1.16ms(-1) (VS(2)) and then at two similar velocities (V(Sim27) and V(Sim37)) determined from two fractions of the N(Fr) (0.27 and 0.37) so that the average group velocity remained unchanged in both conditions (VS(1)=V (Sim27)andVS(2)=V (Sim37)). N(Fr) can theoretically be used to determine walking velocities proportional to leg lengths and to establish dynamic similarities between subjects. This study represents the first attempt at using this approach to examine plantar pressure. The ankle and knee joint angles were studied in the sagittal plane and the plantar pressure distribution was assessed with an in-shoe measurement device. The similarity ratios were computed from anthropometric parameters and plantar pressure peaks. Dynamically similar conditions caused a 25% reduction in leg joint angles variation and a 10% significant decrease in dimensionless pressure peak variability on average of five footprint locations. It also lead to heel and under-midfoot pressure peaks proportional to body mass and to an increase in the number of under-forefoot plantar pressure peaks proportional to body mass and/or leg length. The use of walking velocities derived from N(Fr) allows kinematic and plantar pressure similarities between subjects to be observed and leads to a lower inter-subject variability. In-shoe pressure measurements have proven to be valuable for the understanding of lower extremity function. Set walking velocities used for clinical assessment mask the effects of body size and individual gait mechanics. The anthropometric scaling of walking velocities (fraction of N(Fr)) should improve identification of unique walking strategies and pathological foot functions.
Whang, C Z Y; Bister, D; Sherriff, M
2011-12-01
This study compared peak insertion torque values of six commercially available self-drilling mini-implants [Mini Spider® screw (1.5 × 8 mm), Infinitas® (1.5 × 9 mm), Vector TAS® (1.4 × 8 mm), Dual Top® (1.6 × 8 mm), Tomas Pin® (1.6 × 8 mm), and Ortho-Easy® (1.7 × 6, 8, and 10 mm)]. Twenty implants each were drilled into acrylic rods at a speed of 8 rpm using a motorized torque measurement stand, and the values were recorded in Newton centimetres (Ncm). A further 20 Ortho-Easy® implants with a length of 6 and 10 mm were tested at 8 rpm; 20 implants of 6 mm length were also tested at 4 rpm. Kaplan-Meier estimates of the peak torque values were compared using the log-rank test with multiple comparisons evaluated by Sidak's test. There were significant differences in the maximum torque values for different mini-implants with the same length. The Mini Spider® screw and Infinitas® showed the lowest average torque values (6.5 and 12.4 Ncm) compared with Vector TAS®, Dual ToP®, Tomas Pin®, and Ortho-Easy® (30.9, 29.4, 25.4, and 24.8 Ncm, respectively). There was no correlation between the diameter of the implants and torque values. The Tomas Pin® showed the largest standard deviation (7.7 Ncm) and the Dual Top® implant the smallest (0.6 Ncm). Different insertion speeds did not result in significant differences in peak torque values but the 6 mm mini-implants showed significantly higher torque values than the 8 and 10 mm implants. Using a 'torque limiting' screwdriver or pre-drilling cortical bone to reduce insertion, torque appears justified for some of the tested implants.
Volcanoes in Central Java, Indonesia
NASA Technical Reports Server (NTRS)
1991-01-01
The Indonesian island of Java (8.0S, 112.0) has over 35 active volcanoes, some of which are the most explosive in the world, and form an east/west line of peaks the length of the island. Five are in this image and at least one is thought to be currently active. The plume flowing north from Welirang (just east of the central cloud mass) is believed to be steam emissions. Also, the lack of vegetation at the peak indicates volcanic activity.
Peak-Flux-Density Spectra of Large Solar Radio Bursts and Proton Emission from Flares.
1985-08-19
of the microwave peak (Z 1000 sfu in U-bursts) served as an indicator that the energy release during the impulsive phase was sufficient to produce a... energy or wave- length tends to be prominent in all, and cautions about over-interpreting associa- tions/correlations observed in samples of big flares...Sung, L. S., and McDonald, F. B. (1975) The variation of solar proton energy spectra and size distribution with helio- longitude, Sol. Phys. 41: 189. 28
USB flow characteristics related to noise generation
NASA Technical Reports Server (NTRS)
Brown, W. H.; Reddy, N. N.
1976-01-01
The effects of nozzle and flap geometry on upper surface blown flow field characteristics related to noise generation were examined experimentally using static models. Flow attachment and spreading characteristics were observed using flow visualization techniques. Velocity and turbulence profiles in the trailing edge wake were measured using hot-wire anemometry, and the effects of the geometric variables on peak velocity and turbulence intensity were determined. It is shown that peak trailing edge velocity is a function of the ratio of flow length to modified hydraulic diameter.
Automatic peak selection by a Benjamini-Hochberg-based algorithm.
Abbas, Ahmed; Kong, Xin-Bing; Liu, Zhi; Jing, Bing-Yi; Gao, Xin
2013-01-01
A common issue in bioinformatics is that computational methods often generate a large number of predictions sorted according to certain confidence scores. A key problem is then determining how many predictions must be selected to include most of the true predictions while maintaining reasonably high precision. In nuclear magnetic resonance (NMR)-based protein structure determination, for instance, computational peak picking methods are becoming more and more common, although expert-knowledge remains the method of choice to determine how many peaks among thousands of candidate peaks should be taken into consideration to capture the true peaks. Here, we propose a Benjamini-Hochberg (B-H)-based approach that automatically selects the number of peaks. We formulate the peak selection problem as a multiple testing problem. Given a candidate peak list sorted by either volumes or intensities, we first convert the peaks into [Formula: see text]-values and then apply the B-H-based algorithm to automatically select the number of peaks. The proposed approach is tested on the state-of-the-art peak picking methods, including WaVPeak [1] and PICKY [2]. Compared with the traditional fixed number-based approach, our approach returns significantly more true peaks. For instance, by combining WaVPeak or PICKY with the proposed method, the missing peak rates are on average reduced by 20% and 26%, respectively, in a benchmark set of 32 spectra extracted from eight proteins. The consensus of the B-H-selected peaks from both WaVPeak and PICKY achieves 88% recall and 83% precision, which significantly outperforms each individual method and the consensus method without using the B-H algorithm. The proposed method can be used as a standard procedure for any peak picking method and straightforwardly applied to some other prediction selection problems in bioinformatics. The source code, documentation and example data of the proposed method is available at http://sfb.kaust.edu.sa/pages/software.aspx.
Automatic Peak Selection by a Benjamini-Hochberg-Based Algorithm
Abbas, Ahmed; Kong, Xin-Bing; Liu, Zhi; Jing, Bing-Yi; Gao, Xin
2013-01-01
A common issue in bioinformatics is that computational methods often generate a large number of predictions sorted according to certain confidence scores. A key problem is then determining how many predictions must be selected to include most of the true predictions while maintaining reasonably high precision. In nuclear magnetic resonance (NMR)-based protein structure determination, for instance, computational peak picking methods are becoming more and more common, although expert-knowledge remains the method of choice to determine how many peaks among thousands of candidate peaks should be taken into consideration to capture the true peaks. Here, we propose a Benjamini-Hochberg (B-H)-based approach that automatically selects the number of peaks. We formulate the peak selection problem as a multiple testing problem. Given a candidate peak list sorted by either volumes or intensities, we first convert the peaks into -values and then apply the B-H-based algorithm to automatically select the number of peaks. The proposed approach is tested on the state-of-the-art peak picking methods, including WaVPeak [1] and PICKY [2]. Compared with the traditional fixed number-based approach, our approach returns significantly more true peaks. For instance, by combining WaVPeak or PICKY with the proposed method, the missing peak rates are on average reduced by 20% and 26%, respectively, in a benchmark set of 32 spectra extracted from eight proteins. The consensus of the B-H-selected peaks from both WaVPeak and PICKY achieves 88% recall and 83% precision, which significantly outperforms each individual method and the consensus method without using the B-H algorithm. The proposed method can be used as a standard procedure for any peak picking method and straightforwardly applied to some other prediction selection problems in bioinformatics. The source code, documentation and example data of the proposed method is available at http://sfb.kaust.edu.sa/pages/software.aspx. PMID:23308147
Comparison of transtibial amputee and non-amputee biomechanics during a common turning task.
Segal, Ava D; Orendurff, Michael S; Czerniecki, Joseph M; Schoen, Jason; Klute, Glenn K
2011-01-01
The biomechanics of amputee turning gait has been minimally studied, in spite of its integral relationship with the more complex gait required for household or community ambulation. This study compares the biomechanics of unilateral transtibial amputees and non-amputees completing a common turning task. Full body gait analysis was completed for subjects walking at comparable self-selected speeds around a 1m radius circular path. Peak internal and external rotation moments of the hip, knee and ankle, mediolateral ground reaction impulse (ML GRI), peak effective limb length, and stride length were compared across conditions (non-amputee, amputee prosthetic limb, amputee sound limb). Amputees showed decreased internal rotation moments at the prosthetic limb hip and knee compared to non-amputees, perhaps as a protective mechanism to minimize stress on the residual limb. There was also an increase in amputee sound limb hip external rotation moment in early stance compared to non-amputees, which may be a compensation for the decrease in prosthetic limb internal rotation moment during late stance of the prior step. ML GRI was decreased for the amputee inside limb compared to non-amputee, possibly to minimize the body's acceleration in the direction of the turn. Amputees also exhibited a shorter inside limb stride length compared to non-amputees. Both decreased ML GRI and stride length indicate a COM that is more centered over the base of support, which may minimize the risk of falling. Finally, a longer effective limb length was found for the amputee inside limb turning, possibly due to excessive trunk shift. Published by Elsevier B.V.
Morré, D J; Orczyk, J; Hignite, H; Kim, C
2008-02-01
Cell surface and growth-related NADH oxidases with protein disulfide-thiol interchange activity, ECTO-NOX, exhibit copper-dependent, clock-related, temperature-independent and entrainable patterns of regular oscillations in the rate of oxidation of NAD(P)H as do aqueous solutions of copper salts. Because of time scale similarities, a basis for the oscillatory patterns in nuclear spin orientations of the hydrogen atoms of the copper-associated water was sought. Extended X-ray absorption fine structure (EXAFS) measurements at 9302 eV on pure water were periodic with a ca. 3.5 min peak to peak separation. Decomposition fits revealed 5 unequally spaced maxima similar to those observed previously for Cu(II)Cl(2) to generate a period length of about 18 min. With D(2)O, the period length was proportionately increased by 30% to 24 min. The redox potential of water and of D(2)O also oscillated with 18 and 24 min period lengths, respectively. Measurements in the middle infrared spectral region above a water sample surface revealed apparent oscillations in the two alternative orientations of the nuclear spins (ortho and para) of the hydrogen atoms of the water or D(2)O with 5 unequally spaced maxima and respective period lengths of 18 and 24 min. Thus, the time keeping oscillations of ECTO-NOX proteins appear to reflect the equilibrium dynamics of ortho-para hydrogen atom spin ratios of water where the presence of metal cations such as Cu(II) in solution determine period length.
Zhao, Meifang; Xiang, Wenhua; Tian, Dalun; Deng, Xiangwen; Huang, Zhihong; Zhou, Xiaolu; Peng, Changhui
2013-01-01
Cunninghamia lanceolata (Lamb.) Hook. has been widely planted in subtropical China to meet increasing timber demands, leading to short-rotation practices that deplete soil nutrients. However, increased nitrogen (N) deposition offsets soil N depletion. While long-term experimental data investigating the coupled effects related to short rotation practices and increasing N deposition are scarce, applying model simulations may yield insights. In this study, the CenW3.1 model was validated and parameterized using data from pure C. lanceolata plantations. The model was then used to simulate various changes in long-term productivity. Results indicated that responses of productivity of C. lanceolata plantation to increased N deposition were more related to stand age than N addition, depending on the proportion and age of growing forests. Our results have also shown a rapid peak in growth and N dynamics. The peak is reached sooner and is higher under higher level of N deposition. Short rotation lengths had a greater effect on productivity and N dynamics than high N deposition levels. Productivity and N dynamics decreased as the rotation length decreased. Total productivity levels suggest that a 30-year rotation length maximizes productivity at the 4.9 kg N ha−1 year−1 deposition level. For a specific rotation length, higher N deposition levels resulted in greater overall ecosystem C and N storage, but this positive correlation tendency gradually slowed down with increasing N deposition levels. More pronounced differences in N deposition levels occurred as rotation length decreased. To sustain C. lanceolata plantation productivity without offsite detrimental N effects, the appropriate rotation length is about 20–30 years for N deposition levels below 50 kg N ha−1 year−1 and about 15–20 years for N deposition levels above 50 kg N ha−1 year−1. These results highlight the importance of assessing N effects on carbon management and the long-term productivity of forest ecosystems. PMID:23390533
Lower-body determinants of running economy in male and female distance runners.
Barnes, Kyle R; Mcguigan, Michael R; Kilding, Andrew E
2014-05-01
A variety of training approaches have been shown to improve running economy in well-trained athletes. However, there is a paucity of data exploring lower-body determinants that may affect running economy and account for differences that may exist between genders. Sixty-three male and female distance runners were assessed in the laboratory for a range of metabolic, biomechanical, and neuromuscular measures potentially related to running economy (ml·kg(-1)·min(-1)) at a range of running speeds. At all common test velocities, women were more economical than men (effect size [ES] = 0.40); however, when compared in terms of relative intensity, men had better running economy (ES = 2.41). Leg stiffness (r = -0.80) and moment arm length (r = 0.90) were large-extremely largely correlated with running economy and each other (r = -0.82). Correlations between running economy and kinetic measures (peak force, peak power, and time to peak force) for both genders were unclear. The relationship in stride rate (r = -0.27 to -0.31) was in the opposite direction to that of stride length (r = 0.32-0.49), and the relationship in contact time (r = -0.21 to -0.54) was opposite of that of flight time (r = 0.06-0.74). Although both leg stiffness and moment arm length are highly related to running economy, it seems that no single lower-body measure can completely explain differences in running economy between individuals or genders. Running economy is therefore likely determined from the sum of influences from multiple lower-body attributes.
A wide angle low coherence interferometry based eye length optometer
NASA Astrophysics Data System (ADS)
Meadway, Alexander; Siegwart, John; Wildsoet, Christine; Norton, Thomas; Zhang, Yuhua
2015-03-01
Interest in eye growth regulation has burgeoned with the rise in myopia prevalence world-wide. Eye length and eye shape are fundamental metrics for related research, but current in vivo measurement techniques are generally limited to the optical axis of the eye. We describe a high resolution, time domain low coherence interferometry based optometer for measuring the eye length of small animals over a wide field of view. The system is based upon a Michelson interferometer using a superluminescent diode as a source, including a sample arm and a reference arm. The sample arm is split into two paths by a polarisation beam splitter; one focuses the light on the cornea and the other focuses the light on the retina. This method has a high efficiency of detection for reflections from both surfaces. The reference arm contains a custom high speed linear motor with 25 mm stroke and equipped with a precision displacement encoder. Light reflected from the cornea and the retina is combined with the reference beam to generate low coherence interferograms. Two galvo scanners are employed to steer the light to different angles so that the eye length over a field of view of 20° × 20° can be measured. The system has an axial resolution of 6.8 μm (in air) and the motor provides accurate movement, allowing for precise and repeatable measurement of coherence peak positions. Example scans from a tree shrew are presented.
Enhanced Resonant Tunneling in Symmetric 2D Semiconductor Vertical Heterostructure Transistors.
Campbell, Philip M; Tarasov, Alexey; Joiner, Corey A; Ready, William J; Vogel, Eric M
2015-05-26
Tunneling transistors with negative differential resistance have widespread appeal for both digital and analog electronics. However, most attempts to demonstrate resonant tunneling devices, including graphene-insulator-graphene structures, have resulted in low peak-to-valley ratios, limiting their application. We theoretically demonstrate that vertical heterostructures consisting of two identical monolayer 2D transition-metal dichalcogenide semiconductor electrodes and a hexagonal boron nitride barrier result in a peak-to-valley ratio several orders of magnitude higher than the best that can be achieved using graphene electrodes. The peak-to-valley ratio is large even at coherence lengths on the order of a few nanometers, making these devices appealing for nanoscale electronics.
A biomechanical analysis of a single-row suture anchor fixation of a large bony bankart lesion.
Dyskin, Evgeny; Marzo, John M; Howard, Craig; Ehrensberger, Mark
2014-12-01
This study was conducted to assess whether a single-row suture anchor repair of a bony Bankart lesion comprising 19% of the glenoid length restores peak translational force and glenoid depth compared with the intact shoulder. Nine thawed adult cadaveric shoulders were dissected and mounted in 45° of abduction and 30° of external rotation. A bony Bankart lesion was simulated with an anterior longitudinal osteotomy, parallel to the superoinferior axis of the glenoid, equivalent to 19% of the glenoid length. The humeral head was displaced 10 mm anteriorly at a speed of 2 mm/s with a 50-N compressive load applied. Testing was performed with the glenoid intact, a simulated lesion, and the lesion repaired with 3 single-row suture anchors. Median (interquartile range [IQR]) peak translational force and glenoid depth were reported. The Friedman test and post hoc comparisons with the Wilcoxon signed rank test were used for between-group analyses. Peak translational force decreased after osteotomy (13.7 N; IQR, 9.6 to 15.5 N; P = .01) and increased after the repair (18.3 N; IQR, 18.3 to 20.6 N; P = .01) compared with the intact shoulder (23.7 N; IQR, 16.4 to 29.9 N). Glenoid depth significantly decreased after the osteotomy (0.2 mm; IQR, -0.6 to 0.7 mm) compared with baseline (1.7 mm; IQR, 1.3 to 2.0 mm; P = .01) and increased after repair (0.8 mm; IQR, 0.1 to 1.0 mm; P = .03) compared with the osteotomized shoulder. The glenoid depth of the repair was less than the baseline value (P = .01). Repair of an anterior bony Bankart lesion equivalent to 19% of the glenoid length with 3 suture anchors restored the peak translational force needed to anteriorly displace the humerus relative to the glenoid; however, this technique failed to restore the natural glenoid depth in a laboratory setting. Our findings describe the inability of a single-row suture anchor repair to provide anatomic fixation of the bony Bankart lesion equivalent to 19% of the glenoid length. Published by Elsevier Inc.
Aerodynamic sound of a body in arbitrary, deformable motion, with application to phonation
NASA Astrophysics Data System (ADS)
Howe, M. S.; McGowan, R. S.
2013-08-01
The method of tailored Green's functions advocated by Doak [Acoustic radiation from a turbulent fluid containing foreign bodies, Proceedings of the Royal Society A 254 (1960) 129-145] for the solution of aeroacoustic problems is used to analyse the contribution of the mucosal wave to self-sustained modulation of air flow through the glottis during the production of voiced speech. The amplitude and phase of the aerodynamic surface force that maintains vocal fold vibration are governed by flow separation from the region of minimum cross-sectional area of the glottis, which moves back and forth along its effective length accompanying the mucosal wave peak. The correct phasing is achieved by asymmetric motion of this peak during the opening and closing phases of the glottis. Limit cycle calculations using experimental data of Berry et al. [High-speed digital imaging of the medial surface of the vocal folds, Journal of the Acoustical Society of America110 (2001) 2539-2547] obtained using an excised canine hemilarynx indicate that the mechanism is robust enough to sustain oscillations over a wide range of voicing conditions.
Regional regression of flood characteristics employing historical information
Tasker, Gary D.; Stedinger, J.R.
1987-01-01
Streamflow gauging networks provide hydrologic information for use in estimating the parameters of regional regression models. The regional regression models can be used to estimate flood statistics, such as the 100 yr peak, at ungauged sites as functions of drainage basin characteristics. A recent innovation in regional regression is the use of a generalized least squares (GLS) estimator that accounts for unequal station record lengths and sample cross correlation among the flows. However, this technique does not account for historical flood information. A method is proposed here to adjust this generalized least squares estimator to account for possible information about historical floods available at some stations in a region. The historical information is assumed to be in the form of observations of all peaks above a threshold during a long period outside the systematic record period. A Monte Carlo simulation experiment was performed to compare the GLS estimator adjusted for historical floods with the unadjusted GLS estimator and the ordinary least squares estimator. Results indicate that using the GLS estimator adjusted for historical information significantly improves the regression model. ?? 1987.
Cunningham, Daniel J; Shearer, David A; Carter, Neil; Drawer, Scott; Pollard, Ben; Bennett, Mark; Eager, Robin; Cook, Christian J; Farrell, John; Russell, Mark; Kilduff, Liam P
2018-01-01
The assessment of competitive movement demands in team sports has traditionally relied upon global positioning system (GPS) analyses presented as fixed-time epochs (e.g., 5-40 min). More recently, presenting game data as a rolling average has become prevalent due to concerns over a loss of sampling resolution associated with the windowing of data over fixed periods. Accordingly, this study compared rolling average (ROLL) and fixed-time (FIXED) epochs for quantifying the peak movement demands of international rugby union match-play as a function of playing position. Elite players from three different squads (n = 119) were monitored using 10 Hz GPS during 36 matches played in the 2014-2017 seasons. Players categorised broadly as forwards and backs, and then by positional sub-group (FR: front row, SR: second row, BR: back row, HB: half back, MF: midfield, B3: back three) were monitored during match-play for peak values of high-speed running (>5 m·s-1; HSR) and relative distance covered (m·min-1) over 60-300 s using two types of sample-epoch (ROLL, FIXED). Irrespective of the method used, as the epoch length increased, values for the intensity of running actions decreased (e.g., For the backs using the ROLL method, distance covered decreased from 177.4 ± 20.6 m·min-1 in the 60 s epoch to 107.5 ± 13.3 m·min-1 for the 300 s epoch). For the team as a whole, and irrespective of position, estimates of fixed effects indicated significant between-method differences across all time-points for both relative distance covered and HSR. Movement demands were underestimated consistently by FIXED versus ROLL with differences being most pronounced using 60 s epochs (95% CI HSR: -6.05 to -4.70 m·min-1, 95% CI distance: -18.45 to -16.43 m·min-1). For all HSR time epochs except one, all backs groups increased more (p < 0.01) from FIXED to ROLL than the forward groups. Linear mixed modelling of ROLL data highlighted that for HSR (except 60 s epoch), SR was the only group not significantly different to FR. For relative distance covered all other position groups were greater than the FR (p < 0.05). The FIXED method underestimated both relative distance (~11%) and HSR values (up to ~20%) compared to the ROLL method. These differences were exaggerated for the HSR variable in the backs position who covered the greatest HSR distance; highlighting important consideration for those implementing the FIXED method of analysis. The data provides coaches with a worst-case scenario reference on the running demands required for periods of 60-300 s in length. This information offers novel insight into game demands and can be used to inform the design of training games to increase specificity of preparation for the most demanding phases of matches.
Zhang, Peng; Li, Houqiang; Wang, Honghui; Wong, Stephen T C; Zhou, Xiaobo
2011-01-01
Peak detection is one of the most important steps in mass spectrometry (MS) analysis. However, the detection result is greatly affected by severe spectrum variations. Unfortunately, most current peak detection methods are neither flexible enough to revise false detection results nor robust enough to resist spectrum variations. To improve flexibility, we introduce peak tree to represent the peak information in MS spectra. Each tree node is a peak judgment on a range of scales, and each tree decomposition, as a set of nodes, is a candidate peak detection result. To improve robustness, we combine peak detection and common peak alignment into a closed-loop framework, which finds the optimal decomposition via both peak intensity and common peak information. The common peak information is derived and loopily refined from the density clustering of the latest peak detection result. Finally, we present an improved ant colony optimization biomarker selection method to build a whole MS analysis system. Experiment shows that our peak detection method can better resist spectrum variations and provide higher sensitivity and lower false detection rates than conventional methods. The benefits from our peak-tree-based system for MS disease analysis are also proved on real SELDI data.
Li, Yingying; Pan, Guiming; Liu, Qiyu; Ma, Liang; Xie, Ying; Zhou, Li; Hao, Zhonghua; Wang, Ququan
2018-06-04
Dual plasmonic Au@Cu 2-x S core-shell nanorods (NRs) have been fabricated by using a hydrothermal method and plasmon-coupled effect between the Au core and Cu 2-x S shell in the near-infrared (NIR) region. The extinction spectrum of Au@Cu 2-x S NRs is dominated by the surface plasmon resonance (SPR) of the Cu 2-x S shell, the transverse surface plasmon resonance (TSPR), and the longitudinal surface plasmon resonance (LSPR) of the Au NRs. With the Cu 2-x S shell increasing (fixed Au NRs), the TSPR peak slightly redshifts and the LSPR and SPR peaks blueshift, owing to competition between the redshift of the refractive index effect and blueshift from the plasmon coupled effect. Although, for Au@Cu 2 S NRs, only TSPR and LSPR peaks can be seen and a redshift arises with the increasing Cu 2 S shell thickness, implying that no plasmonic coupling between Au NRs and Cu 2 S shell occurred. The extinction spectrum of the Au@Cu 2-x S NRs with three coupled resonance peaks is simulated by using the FDTD method, taking into account the electron-transfer effect. The dispersion properties of the coupling of Au@Cu 2-x S NRs with the LSPR of the initial Au core are studied experimentally by changing the length of the Au NRs, which are explained theoretically by the coupled harmonic oscillator model. The calculated coupled coefficients between SPR of the Cu 2-x S shell and LSPR of the Au NRs is 180 meV, which is much stronger than that of TSPR of Au NRs of 55 meV. Finally, the enhanced photothermal effect of Au@Cu 2-x S NRs has been demonstrated. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Strampe, Margaret R; Huckenpahler, Alison L; Higgins, Brian P; Tarima, Sergey; Visotcky, Alexis; Stepien, Kimberly E; Kay, Christine N; Carroll, Joseph
2018-05-01
To examine repeatability and reproducibility of ellipsoid zone (EZ) width measurements in patients with retinitis pigmentosa (RP) using a longitudinal reflectivity profile (LRP) analysis. We examined Bioptigen optical coherence tomography (OCT) scans from 48 subjects with RP or Usher syndrome. Nominal scan lengths were 6, 7, or 10 mm, and the lateral scale of each scan was calculated using axial length measurements. LRPs were generated from OCT line scans, and the peak corresponding to EZ was manually identified using ImageJ. The locations at which the EZ peak disappeared were used to calculate EZ width. Each scan was analyzed twice by each of two observers, who were masked to their previous measurements and those of the other observer. On average, horizontal width (HW) was significantly greater than vertical width (VW), and there was high interocular symmetry for both HW and VW. We observed excellent intraobserver repeatability with intraclass correlation coefficients (ICCs) ranging from 0.996 to 0.998 for HW and VW measurements. Interobserver reproducibility was also excellent for both HW (ICC = 0.989; 95% confidence interval [CI] = 0.983-0.995) and VW (ICC = 0.991; 95% CI = 0.985-0.996), with no significant bias observed between observers. EZ width can be measured using LRPs with excellent repeatability and reproducibility. Our observation of greater HW than VW is consistent with previous observations in RP, though the reason for this anisotropy remains unclear. We describe repeatability and reproducibility of a method for measuring EZ width in patients with RP or Usher syndrome. This approach could facilitate measurement of retinal band thickness and/or intensity.
Anthropometry as a predictor of bench press performance done at different loads.
Caruso, John F; Taylor, Skyler T; Lutz, Brant M; Olson, Nathan M; Mason, Melissa L; Borgsmiller, Jake A; Riner, Rebekah D
2012-09-01
The purpose of our study was to examine the ability of anthropometric variables (body mass, total arm length, biacromial width) to predict bench press performance at both maximal and submaximal loads. Our methods required 36 men to visit our laboratory and submit to anthropometric measurements, followed by lifting as much weight as possible in good form one time (1 repetition maximum, 1RM) in the exercise. They made 3 more visits in which they performed 4 sets of bench presses to volitional failure at 1 of 3 (40, 55, or 75% 1RM) submaximal loads. An accelerometer (Myotest Inc., Royal Oak MI) measured peak force, velocity, and power after each submaximal load set. With stepwise multivariate regression, our 3 anthropometric variables attempted to explain significant amounts of variance for 13 bench press performance indices. For criterion measures that reached significance, separate Pearson product moment correlation coefficients further assessed if the strength of association each anthropometric variable had with the criterion was also significant. Our analyses showed that anthropometry explained significant amounts (p < 0.05) of variance for 8 criterion measures. It was concluded that body mass had strong univariate correlations with 1RM and force-related measures, total arm length was moderately associated with 1RM and criterion variables at the lightest load, whereas biacromial width had an inverse relationship with the peak number of repetitions performed per set at the 2 lighter loads. Practical applications suggest results may help coaches and practitioners identify anthropometric features that may best predict various measures of bench press prowess in athletes.
Initial Circulation and Peak Vorticity Behavior of Vortices Shed from Airfoil Vortex Generators
NASA Technical Reports Server (NTRS)
Wendt, Bruce J.; Biesiadny, Tom (Technical Monitor)
2001-01-01
An extensive parametric study of vortices shed from airfoil vortex generators has been conducted to determine the dependence of initial vortex circulation and peak vorticity on elements of the airfoil geometry and impinging flow conditions. These elements include the airfoil angle of attack, chord length, span, aspect ratio, local boundary layer thickness, and free stream Mach number. In addition, the influence of airfoil-to-airfoil spacing on the circulation and peak vorticity has been examined for pairs of co-rotating and counter-rotating vortices. The vortex generators were symmetric airfoils having a NACA-0012 cross-sectional profile. These airfoils were mounted either in isolation, or in pairs, on the surface of a straight pipe. The turbulent boundary layer thickness to pipe radius ratio was about 17 percent. The circulation and peak vorticity data were derived from cross-plane velocity measurements acquired with a seven-hole probe at one chord-length downstream of the airfoil trailing edge location. The circulation is observed to be proportional to the free-stream Mach number, the angle-of-attack, and the span-to-boundary layer thickness ratio. With these parameters held constant, the circulation is observed to fall off in monotonic fashion with increasing airfoil aspect ratio. The peak vorticity is also observed to be proportional to the free-stream Mach number, the airfoil angle-of-attack, and the span-to-boundary layer thickness ratio. Unlike circulation, however, the peak vorticity is observed to increase with increasing aspect ratio, reaching a peak value at an aspect ratio of about 2.0 before falling off again at higher values of aspect ratio. Co-rotating vortices shed from closely spaced pairs of airfoils have values of circulation and peak vorticity under those values found for vortices shed from isolated airfoils of the same geometry. Conversely, counter-rotating vortices show enhanced values of circulation and peak vorticity when compared to values obtained in isolation. The circulation may be accurately modeled with an expression based on Prandtl's relationship between finite airfoil circulation and airfoil geometry. A correlation for the peak vorticity has been derived from a conservation relationship equating the moment at the airfoil tip to the rate of angular momentum production of the shed vortex, modeled as a Lamb (ideal viscous) vortex. This technique provides excellent qualitative agreement to the observed behavior of peak vorticity for low aspect ratio airfoils typically used as vortex generators.
NASA Astrophysics Data System (ADS)
Zhu, Meng-Hua; Liu, Liang-Gang; You, Zhong; Xu, Ao-Ao
2009-03-01
In this paper, a heuristic approach based on Slavic's peak searching method has been employed to estimate the width of peak regions for background removing. Synthetic and experimental data are used to test this method. With the estimated peak regions using the proposed method in the whole spectrum, we find it is simple and effective enough to be used together with the Statistics-sensitive Nonlinear Iterative Peak-Clipping method.
Volumetric Muscle Loss: Persistent Functional Deficits Beyond Frank Loss of Tissue
2014-09-18
ing musculature5,6 that almost certainly changes the muscle’s architecture (e.g., fiber length to muscle length ratio) and composition (e.g...Vivo Isometric Functional Assessment TA muscle in vivo mechanical properties were measured in anesthetized rats (isoflurane 1.5–2.0%) in both legs as...testing system.5 Peak TA muscle isometric torque was determined with the ankle at a right angle 0˚ and 20˚ of dorsi- or plantar flexion, assuming a moment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dorogush, E S; Afonenko, A A
The distributed resonator model is used to show the presence of several resonance responses on the modulation characteristic of optically injection-locked Fabry–Perot lasers. The positions of the resonance peaks on the modulation characteristic are determined by the resonator length and frequency detuning of optical injection. It is shown that an appropriate choice of the resonator length and injection locking conditions allows one to obtain efficient modulation in two ranges near 40 – 60 GHz or to increase the direct modulation bandwidth up to 50 GHz. (control of laser radiation parameters)
Plasma influence on the dispersion properties of finite-length, corrugated waveguides
NASA Astrophysics Data System (ADS)
Shkvarunets, A.; Kobayashi, S.; Weaver, J.; Carmel, Y.; Rodgers, J.; Antonsen, T. M., Jr.; Granatstein, V. L.; Destler, W. W.; Ogura, K.; Minami, K.
1996-03-01
We present an experimental study of the electromagnetic properties of transverse magnetic modes in a corrugated-wall cavity filled with a radially inhomogeneous plasma. The shifts of the resonant frequencies of a finite-length, corrugated cavity were measured as a function of the background plasma density and the dispersion diagram was reconstructed up to a peak plasma density of 1012 cm-3. Good agreement with a calculated dispersion diagram is obtained for plasma densities below 5×1011 cm-3.
NASA Astrophysics Data System (ADS)
Bassett, C.; Andrus, C. F. T.
2015-12-01
Sclerochronological analysis of biogenic carbonates provides valuable paleoenvironmental information. Oxygen isotope analysis of bivalve shell yields information on the temperature of the water in which the organism grew. However, in coastal environments, variations in δ18Owater may complicate the interpretation of shell isotope profiles. Measuring and comparing the length of seasonal shell growth in select species of bivalves may complement isotopic analysis, together providing a more precise paleoclimate reconstruction. This project aims to determine the reliability of sclerochronological analysis of bivalves in reconstructing seasonality along the Northwest Coast of North America. To compare bivalves growing at different seasonal temperature conditions, samples of Saxidomus gigantea were collected from southern Alaska and northern British Columbia. Winter cessation lines were identified using oxygen isotope (δ18O) peaks from a profile of variation over the life of the clam, which was sampled sequentially from a section of its shell. Shell growth stops below ~4-5°C and so each winter cessation indicates temperatures lower than this threshold. Lunar-daily growth lines were counted between these winter growth cessation breaks, which quantitatively measure the length of the growing season. The resulting data were compared between habitats to assess if this is a useful method of determining the length of the growing season. If this method of assessing seasonality appears valid, it can be applied to ancient shells abundant in archaeological shell middens to make inferences about past seawater conditions and potentially indicate the presence or absence of the conditions necessary for sea ice accumulation.
Ruiz-Arrondo, Ignacio; Garza-Hernández, Javier A; Reyes-Villanueva, Filiberto; Lucientes-Curdi, Javier; Rodríguez-Pérez, Mario A
2017-04-08
Simulium (Boophthora) erythrocephalum (De Geer, 1776) is one of the blackfly species responsible for major public health problems in Europe. Blackfly outbreaks of this species are becoming more frequent, threatening public health in Spain. In the present study, bionomic parameters of S. erythrocephalum in northeastern Spain were estimated. Simulium erythrocephalum was collected from May through June 2015 in Zaragoza, Spain, using the human-landing-collection (HLC) method. Daily pattern of total and parous landing activity was estimated, as was the gonotrophic cycle (GC) length and survivorship (S) rate, using time series analysis. Host-seeking females of S. erythrocephalum showed a bimodal human-landing activity pattern, with a minor and major peak at dawn and dusk, respectively; there was a significant negative association between human daily landing rate and temperature (P = 0.003) and solar radiation (P < 0.001). Overall, a daily landing rate (DLR) of 34 lands/person/day was estimated. Series of sequential data analysis on parity showed the highest significant (P < 0.001) correlation indices (r = 0.45 and r = 0.39 for raw and filtered data) for a 2-day time lag, indicating that the GC length corresponded to 2 days. Daily survivorship and parity rate were 0.85 and 0.72, respectively. Simulium erythrocephalum was confirmed as a nuisance species in Zaragoza, using the HLC method for the first time in Spain. The data offer insights into the ecology of S. erythrocephalum, which can improve management strategies of this pest in Spain.
Gao, Shen; Yao, Bei; Lu, Zuhong
2015-01-01
Background The chimeric sequences produced by phi29 DNA polymerase, which are named as chimeras, influence the performance of the multiple displacement amplification (MDA) and also increase the difficulty of sequence data process. Despite several articles have reported the existence of chimeric sequence, there was only one research focusing on the structure and generation mechanism of chimeras, and it was merely based on hundreds of chimeras found in the sequence data of E. coli genome. Method We finished data mining towards a series of Next Generation Sequencing (NGS) reads which were used for whole genome haplotype assembling in a primary study. We established a bioinformatics pipeline based on subsection alignment strategy to discover all the chimeras inside and achieve their structural visualization. Then, we artificially defined two statistical indexes (the chimeric distance and the overlap length), and their regular abundance distribution helped illustrate of the structural characteristics of the chimeras. Finally we analyzed the relationship between the chimera type and the average insertion size, so that illustrate a method to decrease the proportion of wasted data in the procedure of DNA library construction. Results/Conclusion 131.4 Gb pair-end (PE) sequence data was reanalyzed for the chimeras. Totally, 40,259,438 read pairs (6.19%) with chimerism were discovered among 650,430,811 read pairs. The chimeric sequences are consisted of two or more parts which locate inconsecutively but adjacently on the chromosome. The chimeric distance between the locations of adjacent parts on the chromosome followed an approximate bimodal distribution ranging from 0 to over 5,000 nt, whose peak was at about 250 to 300 nt. The overlap length of adjacent parts followed an approximate Poisson distribution and revealed a peak at 6 nt. Moreover, unmapped chimeras, which were classified as the wasted data, could be reduced by properly increasing the length of the insertion segment size through a linear correlation analysis. Significance This study exhibited the profile of the phi29MDA chimeras by tens of millions of chimeric sequences, and helped understand the amplification mechanism of the phi29 DNA polymerase. Our work also illustrated the importance of NGS data reanalysis, not only for the improvement of data utilization efficiency, but also for more potential genomic information. PMID:26440104
Correction factors to convert microdosimetry measurements in silicon to tissue in 12C ion therapy
NASA Astrophysics Data System (ADS)
Bolst, David; Guatelli, Susanna; Tran, Linh T.; Chartier, Lachlan; Lerch, Michael L. F.; Matsufuji, Naruhiro; Rosenfeld, Anatoly B.
2017-03-01
Silicon microdosimetry is a promising technology for heavy ion therapy (HIT) quality assurance, because of its sub-mm spatial resolution and capability to determine radiation effects at a cellular level in a mixed radiation field. A drawback of silicon is not being tissue-equivalent, thus the need to convert the detector response obtained in silicon to tissue. This paper presents a method for converting silicon microdosimetric spectra to tissue for a therapeutic 12C beam, based on Monte Carlo simulations. The energy deposition spectra in a 10 μm sized silicon cylindrical sensitive volume (SV) were found to be equivalent to those measured in a tissue SV, with the same shape, but with dimensions scaled by a factor κ equal to 0.57 and 0.54 for muscle and water, respectively. A low energy correction factor was determined to account for the enhanced response in silicon at low energy depositions, produced by electrons. The concept of the mean path length < {{l}\\text{Path}}> to calculate the lineal energy was introduced as an alternative to the mean chord length < l> because it was found that adopting Cauchy’s formula for the < l> was not appropriate for the radiation field typical of HIT as it is very directional. < {{l}\\text{Path}}> can be determined based on the peak of the lineal energy distribution produced by the incident carbon beam. Furthermore it was demonstrated that the thickness of the SV along the direction of the incident 12C ion beam can be adopted as < {{l}\\text{Path}}> . The tissue equivalence conversion method and < {{l}\\text{Path}}> were adopted to determine the RBE10, calculated using a modified microdosimetric kinetic model, applied to the microdosimetric spectra resulting from the simulation study. Comparison of the RBE10 along the Bragg peak to experimental TEPC measurements at HIMAC, NIRS, showed good agreement. Such agreement demonstrates the validity of the developed tissue equivalence correction factors and of the determination of < {{l}\\text{Path}}> .
RF pulse compression for future linear colliders
NASA Astrophysics Data System (ADS)
Wilson, Perry B.
1995-07-01
Future (nonsuperconducting) linear colliders will require very high values of peak rf power per meter of accelerating structure. The role of rf pulse compression in producing this power is examined within the context of overall rf system design for three future colliders at energies of 1.0-1.5 TeV, 5 TeV, and 25 TeV. In order to keep the average AC input power and the length of the accelerator within reasonable limits, a collider in the 1.0-1.5 TeV energy range will probably be built at an x-band rf frequency, and will require a peak power on the order of 150-200 MW per meter of accelerating structure. A 5 TeV collider at 34 GHz with a reasonable length (35 km) and AC input power (225 MW) would require about 550 MW per meter of structure. Two-beam accelerators can achieve peak powers of this order by applying dc pulse compression techniques (induction linac modules) to produce the drive beam. Klystron-driven colliders achieve high peak power by a combination of dc pulse compression (modulators) and rf pulse compression, with about the same overall rf system efficiency (30-40%) as a two-beam collider. A high gain (6.8) three-stage binary pulse compression system with high efficiency (80%) is described, which (compared to a SLED-II system) can be used to reduce the klystron peak power by about a factor of two, or alternatively, to cut the number of klystrons in half for a 1.0-1.5 TeV x-band collider. For a 5 TeV klystron-driven collider, a high gain, high efficiency rf pulse compression system is essential.
NASA Astrophysics Data System (ADS)
Morasse, Bertrand; Plourde, Estéban
2017-02-01
We present a simple way to achieve and optimize hundreds of kW peak power pulsed output using a monolithic amplifier chain based on solid core double cladding fiber tightly packaged. A fiber pigtailed current driven diode is used to produce nanosecond pulses at 1064 nm. We present how to optimize the use of Fabry-Perot versus DFB type diode along with the proper wavelength locking using a fiber Bragg grating. The optimization of the two pre-amplifiers with respect to the pump wavelength and Yb inversions is presented. We explain how to manage ASE using core and cladding pumping and by using single pass and double pass amplifier. ASE rejection within the Yb fiber itself and with the use of bandpass filter is discussed. Maximizing the amplifier conversion efficiency with regards to the fiber parameters, glass matrix and signal wavelength is described in details. We present how to achieve high peak power at the power amplifier stage using large core/cladding diameter ratio highly doped Yb fibers pumped at 975 nm. The effect of pump bleaching on the effective Yb fiber length is analyzed carefully. We demonstrate that counter-pumping brings little advantage in very short length amplifier. Dealing with the self-pulsation limit of stimulated Brillouin scattering is presented with the adjustment of the seed pulsewidth and linewidth. Future prospects for doubling the output peak power are discussed.
Bojesen, Stig E; Pooley, Karen A; Johnatty, Sharon E; Beesley, Jonathan; Michailidou, Kyriaki; Tyrer, Jonathan P; Edwards, Stacey L; Pickett, Hilda A; Shen, Howard C; Smart, Chanel E; Hillman, Kristine M; Mai, Phuong L; Lawrenson, Kate; Stutz, Michael D; Lu, Yi; Karevan, Rod; Woods, Nicholas; Johnston, Rebecca L; French, Juliet D; Chen, Xiaoqing; Weischer, Maren; Nielsen, Sune F; Maranian, Melanie J; Ghoussaini, Maya; Ahmed, Shahana; Baynes, Caroline; Bolla, Manjeet K; Wang, Qin; Dennis, Joe; McGuffog, Lesley; Barrowdale, Daniel; Lee, Andrew; Healey, Sue; Lush, Michael; Tessier, Daniel C; Vincent, Daniel; Bacot, Françis; Vergote, Ignace; Lambrechts, Sandrina; Despierre, Evelyn; Risch, Harvey A; González-Neira, Anna; Rossing, Mary Anne; Pita, Guillermo; Doherty, Jennifer A; Alvarez, Nuria; Larson, Melissa C; Fridley, Brooke L; Schoof, Nils; Chang-Claude, Jenny; Cicek, Mine S; Peto, Julian; Kalli, Kimberly R; Broeks, Annegien; Armasu, Sebastian M; Schmidt, Marjanka K; Braaf, Linde M; Winterhoff, Boris; Nevanlinna, Heli; Konecny, Gottfried E; Lambrechts, Diether; Rogmann, Lisa; Guénel, Pascal; Teoman, Attila; Milne, Roger L; Garcia, Joaquin J; Cox, Angela; Shridhar, Vijayalakshmi; Burwinkel, Barbara; Marme, Frederik; Hein, Rebecca; Sawyer, Elinor J; Haiman, Christopher A; Wang-Gohrke, Shan; Andrulis, Irene L; Moysich, Kirsten B; Hopper, John L; Odunsi, Kunle; Lindblom, Annika; Giles, Graham G; Brenner, Hermann; Simard, Jacques; Lurie, Galina; Fasching, Peter A; Carney, Michael E; Radice, Paolo; Wilkens, Lynne R; Swerdlow, Anthony; Goodman, Marc T; Brauch, Hiltrud; Garcia-Closas, Montserrat; Hillemanns, Peter; Winqvist, Robert; Dürst, Matthias; Devilee, Peter; Runnebaum, Ingo; Jakubowska, Anna; Lubinski, Jan; Mannermaa, Arto; Butzow, Ralf; Bogdanova, Natalia V; Dörk, Thilo; Pelttari, Liisa M; Zheng, Wei; Leminen, Arto; Anton-Culver, Hoda; Bunker, Clareann H; Kristensen, Vessela; Ness, Roberta B; Muir, Kenneth; Edwards, Robert; Meindl, Alfons; Heitz, Florian; Matsuo, Keitaro; du Bois, Andreas; Wu, Anna H; Harter, Philipp; Teo, Soo-Hwang; Schwaab, Ira; Shu, Xiao-Ou; Blot, William; Hosono, Satoyo; Kang, Daehee; Nakanishi, Toru; Hartman, Mikael; Yatabe, Yasushi; Hamann, Ute; Karlan, Beth Y; Sangrajrang, Suleeporn; Kjaer, Susanne Krüger; Gaborieau, Valerie; Jensen, Allan; Eccles, Diana; Høgdall, Estrid; Shen, Chen-Yang; Brown, Judith; Woo, Yin Ling; Shah, Mitul; Azmi, Mat Adenan Noor; Luben, Robert; Omar, Siti Zawiah; Czene, Kamila; Vierkant, Robert A; Nordestgaard, Børge G; Flyger, Henrik; Vachon, Celine; Olson, Janet E; Wang, Xianshu; Levine, Douglas A; Rudolph, Anja; Weber, Rachel Palmieri; Flesch-Janys, Dieter; Iversen, Edwin; Nickels, Stefan; Schildkraut, Joellen M; Silva, Isabel Dos Santos; Cramer, Daniel W; Gibson, Lorna; Terry, Kathryn L; Fletcher, Olivia; Vitonis, Allison F; van der Schoot, C Ellen; Poole, Elizabeth M; Hogervorst, Frans B L; Tworoger, Shelley S; Liu, Jianjun; Bandera, Elisa V; Li, Jingmei; Olson, Sara H; Humphreys, Keith; Orlow, Irene; Blomqvist, Carl; Rodriguez-Rodriguez, Lorna; Aittomäki, Kristiina; Salvesen, Helga B; Muranen, Taru A; Wik, Elisabeth; Brouwers, Barbara; Krakstad, Camilla; Wauters, Els; Halle, Mari K; Wildiers, Hans; Kiemeney, Lambertus A; Mulot, Claire; Aben, Katja K; Laurent-Puig, Pierre; Altena, Anne Mvan; Truong, Thérèse; Massuger, Leon F A G; Benitez, Javier; Pejovic, Tanja; Perez, Jose Ignacio Arias; Hoatlin, Maureen; Zamora, M Pilar; Cook, Linda S; Balasubramanian, Sabapathy P; Kelemen, Linda E; Schneeweiss, Andreas; Le, Nhu D; Sohn, Christof; Brooks-Wilson, Angela; Tomlinson, Ian; Kerin, Michael J; Miller, Nicola; Cybulski, Cezary; Henderson, Brian E; Menkiszak, Janusz; Schumacher, Fredrick; Wentzensen, Nicolas; Le Marchand, Loic; Yang, Hannah P; Mulligan, Anna Marie; Glendon, Gord; Engelholm, Svend Aage; Knight, Julia A; Høgdall, Claus K; Apicella, Carmel; Gore, Martin; Tsimiklis, Helen; Song, Honglin; Southey, Melissa C; Jager, Agnes; den Ouweland, Ans M Wvan; Brown, Robert; Martens, John W M; Flanagan, James M; Kriege, Mieke; Paul, James; Margolin, Sara; Siddiqui, Nadeem; Severi, Gianluca; Whittemore, Alice S; Baglietto, Laura; McGuire, Valerie; Stegmaier, Christa; Sieh, Weiva; Müller, Heiko; Arndt, Volker; Labrèche, France; Gao, Yu-Tang; Goldberg, Mark S; Yang, Gong; Dumont, Martine; McLaughlin, John R; Hartmann, Arndt; Ekici, Arif B; Beckmann, Matthias W; Phelan, Catherine M; Lux, Michael P; Permuth-Wey, Jenny; Peissel, Bernard; Sellers, Thomas A; Ficarazzi, Filomena; Barile, Monica; Ziogas, Argyrios; Ashworth, Alan; Gentry-Maharaj, Aleksandra; Jones, Michael; Ramus, Susan J; Orr, Nick; Menon, Usha; Pearce, Celeste L; Brüning, Thomas; Pike, Malcolm C; Ko, Yon-Dschun; Lissowska, Jolanta; Figueroa, Jonine; Kupryjanczyk, Jolanta; Chanock, Stephen J; Dansonka-Mieszkowska, Agnieszka; Jukkola-Vuorinen, Arja; Rzepecka, Iwona K; Pylkäs, Katri; Bidzinski, Mariusz; Kauppila, Saila; Hollestelle, Antoinette; Seynaeve, Caroline; Tollenaar, Rob A E M; Durda, Katarzyna; Jaworska, Katarzyna; Hartikainen, Jaana M; Kosma, Veli-Matti; Kataja, Vesa; Antonenkova, Natalia N; Long, Jirong; Shrubsole, Martha; Deming-Halverson, Sandra; Lophatananon, Artitaya; Siriwanarangsan, Pornthep; Stewart-Brown, Sarah; Ditsch, Nina; Lichtner, Peter; Schmutzler, Rita K; Ito, Hidemi; Iwata, Hiroji; Tajima, Kazuo; Tseng, Chiu-Chen; Stram, Daniel O; van den Berg, David; Yip, Cheng Har; Ikram, M Kamran; Teh, Yew-Ching; Cai, Hui; Lu, Wei; Signorello, Lisa B; Cai, Qiuyin; Noh, Dong-Young; Yoo, Keun-Young; Miao, Hui; Iau, Philip Tsau-Choong; Teo, Yik Ying; McKay, James; Shapiro, Charles; Ademuyiwa, Foluso; Fountzilas, George; Hsiung, Chia-Ni; Yu, Jyh-Cherng; Hou, Ming-Feng; Healey, Catherine S; Luccarini, Craig; Peock, Susan; Stoppa-Lyonnet, Dominique; Peterlongo, Paolo; Rebbeck, Timothy R; Piedmonte, Marion; Singer, Christian F; Friedman, Eitan; Thomassen, Mads; Offit, Kenneth; Hansen, Thomas V O; Neuhausen, Susan L; Szabo, Csilla I; Blanco, Ignacio; Garber, Judy; Narod, Steven A; Weitzel, Jeffrey N; Montagna, Marco; Olah, Edith; Godwin, Andrew K; Yannoukakos, Drakoulis; Goldgar, David E; Caldes, Trinidad; Imyanitov, Evgeny N; Tihomirova, Laima; Arun, Banu K; Campbell, Ian; Mensenkamp, Arjen R; van Asperen, Christi J; van Roozendaal, Kees E P; Meijers-Heijboer, Hanne; Collée, J Margriet; Oosterwijk, Jan C; Hooning, Maartje J; Rookus, Matti A; van der Luijt, Rob B; Os, Theo A Mvan; Evans, D Gareth; Frost, Debra; Fineberg, Elena; Barwell, Julian; Walker, Lisa; Kennedy, M John; Platte, Radka; Davidson, Rosemarie; Ellis, Steve D; Cole, Trevor; Bressac-de Paillerets, Brigitte; Buecher, Bruno; Damiola, Francesca; Faivre, Laurence; Frenay, Marc; Sinilnikova, Olga M; Caron, Olivier; Giraud, Sophie; Mazoyer, Sylvie; Bonadona, Valérie; Caux-Moncoutier, Virginie; Toloczko-Grabarek, Aleksandra; Gronwald, Jacek; Byrski, Tomasz; Spurdle, Amanda B; Bonanni, Bernardo; Zaffaroni, Daniela; Giannini, Giuseppe; Bernard, Loris; Dolcetti, Riccardo; Manoukian, Siranoush; Arnold, Norbert; Engel, Christoph; Deissler, Helmut; Rhiem, Kerstin; Niederacher, Dieter; Plendl, Hansjoerg; Sutter, Christian; Wappenschmidt, Barbara; Borg, Ake; Melin, Beatrice; Rantala, Johanna; Soller, Maria; Nathanson, Katherine L; Domchek, Susan M; Rodriguez, Gustavo C; Salani, Ritu; Kaulich, Daphne Gschwantler; Tea, Muy-Kheng; Paluch, Shani Shimon; Laitman, Yael; Skytte, Anne-Bine; Kruse, Torben A; Jensen, Uffe Birk; Robson, Mark; Gerdes, Anne-Marie; Ejlertsen, Bent; Foretova, Lenka; Savage, Sharon A; Lester, Jenny; Soucy, Penny; Kuchenbaecker, Karoline B; Olswold, Curtis; Cunningham, Julie M; Slager, Susan; Pankratz, Vernon S; Dicks, Ed; Lakhani, Sunil R; Couch, Fergus J; Hall, Per; Monteiro, Alvaro N A; Gayther, Simon A; Pharoah, Paul D P; Reddel, Roger R; Goode, Ellen L; Greene, Mark H; Easton, Douglas F; Berchuck, Andrew; Antoniou, Antonis C; Chenevix-Trench, Georgia; Dunning, Alison M
2013-04-01
TERT-locus SNPs and leukocyte telomere measures are reportedly associated with risks of multiple cancers. Using the Illumina custom genotyping array iCOGs, we analyzed ∼480 SNPs at the TERT locus in breast (n = 103,991), ovarian (n = 39,774) and BRCA1 mutation carrier (n = 11,705) cancer cases and controls. Leukocyte telomere measurements were also available for 53,724 participants. Most associations cluster into three independent peaks. The minor allele at the peak 1 SNP rs2736108 associates with longer telomeres (P = 5.8 × 10(-7)), lower risks for estrogen receptor (ER)-negative (P = 1.0 × 10(-8)) and BRCA1 mutation carrier (P = 1.1 × 10(-5)) breast cancers and altered promoter assay signal. The minor allele at the peak 2 SNP rs7705526 associates with longer telomeres (P = 2.3 × 10(-14)), higher risk of low-malignant-potential ovarian cancer (P = 1.3 × 10(-15)) and greater promoter activity. The minor alleles at the peak 3 SNPs rs10069690 and rs2242652 increase ER-negative (P = 1.2 × 10(-12)) and BRCA1 mutation carrier (P = 1.6 × 10(-14)) breast and invasive ovarian (P = 1.3 × 10(-11)) cancer risks but not via altered telomere length. The cancer risk alleles of rs2242652 and rs10069690, respectively, increase silencing and generate a truncated TERT splice variant.
Determination of haloacetic acids in water by ion chromatography--method development.
Lopez-Avila, V; Liu, Y; Charan, C
1999-01-01
The microextraction/ion chromatographic (IC) method developed in this study involves extraction of 9 haloacetic acids (HAAs) from aqueous samples (acidified with sulfuric acid to a pH of < 0.5 and amended with copper sulfate pentahydrate and sodium sulfate) with methyl tert-butyl ether (MTBE), back extraction into reagent water, and analysis by IC with conductivity detection. The separation column consists of an Ion Pac AG-11 (2 mm id x 50 mm length) guard column and an Ion Pac AS-11 (2 mm id x 250 mm length) analytical column, and the concentration column is a 4 mm id x 35 mm length Dionex TAC-LP column. Use of the 2 mm id Dionex AS-11 column improved detection limits especially for trichloracetic acid (TCAA), bromodichloroacetic acid (BDCAA), dibromochloroacetic acid (DBCAA), and tribromoacetic acid (TBAA). The peak interfering with BCAA elutes at the same retention time as nitrate; however, we have not confirmed the presence of nitrate. Stability studies indicate that HAAs are stable in water for at least 8 days when preserved with ammonium chloride at 100 mg/L and stored at 4 degrees C in the dark. At day 30, recoveries were still high (e.g., 92.1-106%) for dichloroacetic acid (DCAA), BCAA, dibromoacetic acid (DBAA), trichloroacetic acid (TCAA), BDCAA, and DBCAA. However, recoveries of monochloroacetic acid (MCAA), monobromoacetic acid (MBAA), and TBAA were only 54.6, 56.8, and 66.8%, respectively. Stability studies of HAAs in H2SO4-saturated MTBE indicate that all compounds except TBAA are stable for 48 h when stored at 4 degrees C in the dark. TBAA recoveries dropped to 47.1% after 6 h of storage and no TBAA was detected after 48 h of storage. The method described here is only preliminary and was tested in only one laboratory. Additional research is needed to improve method performance.
Székely, Gy; Henriques, B; Gil, M; Ramos, A; Alvarez, C
2012-11-01
The present study reports on a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method development strategy supported by design of experiments (DoE) for the trace analysis of 4-dimethylaminopyridine (DMAP). The conventional approaches for development of LC-MS/MS methods are usually via trial and error, varying intentionally the experimental factors which is time consuming and interactions between experimental factors are not considered. The LC factors chosen for the DoE study include flow (F), gradient (G) and injection volume (V(inj)) while cone voltage (E(con)) and collision energy (E(col)) were chosen as MS parameters. All of the five factors were studied simultaneously. The method was optimized with respect to four responses: separation of peaks (Sep), peak area (A(peak)), length of the analysis (T) and the signal to noise ratio (S/N). A quadratic model, namely central composite face (CCF) featuring 29 runs was used instead of a less powerful linear model since the increase in the number of injections was insignificant. In order to determine the robustness of the method a new set of DoE experiments was carried out applying robustness around the optimal conditions was evaluated applying a fractional factorial of resolution III with 11 runs, wherein additional factors - such as column temperature and quadrupole resolution - were considered. The method utilizes a Phenomenex Gemini NX C-18 HPLC analytical column with electrospray ionization and a triple quadrupole mass detector in multiple reaction monitoring (MRM) mode, resulting in short analyses with a 10min runtime. Drawbacks of derivatization, namely incomplete reaction and time consuming sample preparation, have been avoided and the change from SIM to MRM mode resulted in increased sensitivity and lower LOQ. The DoE method development strategy led to a method allowing the trace analysis of DMAP at 0.5 ng/ml absolute concentration which corresponds to a 0.1 ppm limit of quantification in 5mg/ml mometasone furoate glucocorticoid. The obtained method was validated in a linear range of 0.1-10 ppm and presented a %RSD of 0.02% for system precision. Regarding DMAP recovery in mometasone furoate, spiked samples produced %recoveries between 83 and 113% in the range of 0.1-2 ppm. Copyright © 2012 Elsevier B.V. All rights reserved.
Numerical analysis of laser-driven reservoir dynamics for shockless loading
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li Mu; Zhang Hongping; Sun Chengwei
2011-05-01
Laser-driven plasma loader for shockless compression provides a new approach to study the rapid compression response of materials not attainable in conventional shock experiments. In this method, the strain rate is varied from {approx}10{sup 6}/s to {approx}10{sup 8}/s, significantly higher than other shockless compression methods. Thus, this loading process is attractive in the research of solid material dynamics and astrophysics. The objective of the current study is to demonstrate the dynamic properties of the jet from the rear surface of the reservoir, and how important parameters such as peak load, rise time, shockless compression depth, and stagnating melt depth inmore » the sample vary with laser intensity, laser pulse length, reservoir thickness, vacuum gap size, and even the sample material. Numerical simulations based on the space-time conservation element and solution element method, together with the bulk ablation model, were used. The dynamics of the reservoir depend on the laser intensity, pulse length, equation of state, as well as the molecular structure of the reservoir. The critical pressure condition at which the reservoir will unload, similar to a gas or weak plasma, is 40-80 GPa before expansion. The momentum distribution bulges downward near the front of the plasma jet, which is an important characteristic that determines shockless compression. The total energy density is the most important parameter, and has great influence on the jet characteristics, and consequently on the shockless compression characteristics. If the reservoir is of a single material irradiated at a given laser condition, the relation of peak load and shockless compression depth is in conflict, and the highest loads correspond to the smallest thickness of sample. The temperature of jet front runs up several electron volts after impacting on the sample, and the heat transfer between the stagnating plasma and the sample is sufficiently significant to induce the melting of the sample surface. However, this diffusion heat wave propagates much more slowly than the stress wave, and has minimal effect on the shockless compression progress at a deeper position.« less
Driscoll, Daniel G.; Southard, Rodney E.; Koenig, Todd A.; Bender, David A.; Holmes, Robert R.
2014-01-01
During 2011, excess precipitation resulted in widespread flooding in the Central United States with 33 fatalities and approximately $4.2 billion in damages reported in the Red River of the North, Souris, and Mississippi River Basins. At different times from late February 2011 through September 2011, various rivers in these basins had major flooding, with some locations having multiple rounds of flooding. This report provides broadscale characterizations of annual exceedance probabilities and trends for peak streamflows and annual runoff volumes for selected streamgages in the Central United States in areas affected by 2011 flooding. Annual exceedance probabilities (AEPs) were analyzed for 321 streamgages for annual peak streamflow and for 211 streamgages for annual runoff volume. Some of the most exceptional flooding was for the Souris River Basin, where of 11 streamgages considered for AEP analysis of peak streamflow, flood peaks in 2011 exceeded the next largest peak of record by at least double for 6 of the longest-term streamgages (75 to 108 years of peak-flow record). AEPs for these six streamgages were less than 1 percent. AEPs for 2011 runoff volumes were less than 1 percent for all seven Souris River streamgages considered for AEP analysis. Magnitudes of 2011 runoff volumes exceeded previous maxima by double or more for 5 of the 7 streamgages (record lengths 52 to 108 years). For the Red River of the North Basin, AEPs for 2011 runoff volumes were exceptional, with two streamgages having AEPs less than 0.2 percent, five streamgages in the range of 0.2 to 1 percent, and four streamgages in the range of 1 to 2 percent. Magnitudes of 2011 runoff volumes also were exceptional, with all 11 of the aforementioned streamgages eclipsing previous long-term (62 to 110 years) annual maxima by about one-third or more. AEPs for peak streamflows in the upper Mississippi River Basin were not exceptional, with no AEPs less than 1 percent. AEPs for annual runoff volumes indicated less frequent recurrence, with 11 streamgages having AEPs of less than 1 percent. The 2011 runoff volume for streamgage 05331000 (at Saint Paul, Minnesota) exceeded the previous record (112 years of record) by about 24 percent. An especially newsworthy feature was prolonged flooding along the main stem of the Missouri River downstream from Garrison Dam (located upstream from Bismarck, North Dakota) and extending downstream throughout the length of the Missouri River. The 2011 runoff volume for streamgage 06342500 (at Bismarck) exceeded the previous (1975) maximum by about 50 percent, with an associated AEP in the range of 0.2 to 1 percent. In the Ohio River Basin, peak-streamflow AEPs were less than 2 percent for only four streamgages. Runoff-volume AEPs were less than 2 percent for only three streamgages. Along the lower Mississippi River, the largest streamflow peak in 91 years was recorded for streamgage 07289000 (at Vicksburg, Mississippi), with an associated AEP of 0.8 percent. Trends in peak streamflow were analyzed for 98 streamgages, with 67 streamgages having upward trends, 31 with downward trends, and zero with no trend. Trends in annual runoff volume were analyzed for 182 streamgages, with 145 streamgages having upward trends, 36 with downward trends, and 1 with no trend. The trend analyses used descriptive methods that did not include measures of statistical significance. A dichotomous spatial distribution in trends was apparent for both peak streamflow and annual runoff volume, with a small number of streamgages in the northwestern part of the study area having downward trends and most streamgages in the eastern part of the study area having upward trends.
Multipath interference test method for distributed amplifiers
NASA Astrophysics Data System (ADS)
Okada, Takahiro; Aida, Kazuo
2005-12-01
A method for testing distributed amplifiers is presented; the multipath interference (MPI) is detected as a beat spectrum between the multipath signal and the direct signal using a binary frequency shifted keying (FSK) test signal. The lightwave source is composed of a DFB-LD that is directly modulated by a pulse stream passing through an equalizer, and emits the FSK signal of the frequency deviation of about 430MHz at repetition rate of 80-100 kHz. The receiver consists of a photo-diode and an electrical spectrum analyzer (ESA). The base-band power spectrum peak appeared at the frequency of the FSK frequency deviation can be converted to amount of MPI using a calibration chart. The test method has improved the minimum detectable MPI as low as -70 dB, compared to that of -50 dB of the conventional test method. The detailed design and performance of the proposed method are discussed, including the MPI simulator for calibration procedure, computer simulations for evaluating the error caused by the FSK repetition rate and the fiber length under test and experiments on singlemode fibers and distributed Raman amplifier.
NASA Technical Reports Server (NTRS)
Hassan, G. K. Y.
1994-01-01
A world wide interest in protecting ozone layer against manmade effects is now increasing. Assessment of the ozone depletion due to these activities depends on how successfully we can separate the natural variabilities from the data. The monthly mean values of total ozone over Cairo (30 05N) for the period 1968-1988, have been analyzed using the power spectral analysis technique. The technique used in this analysis does not depend on a pre-understanding of the natural fluctuations in the ozone data. The method depends on increasing the resolution of the spectral peaks in order to obtain the more accurate sinusoidal fluctuations with wavelength equal to or less than record length. Also it handles the possible sinusoidal fluctuations with wavelength equal to or less than record length. The results show that it is possible to detect some of the well known national fluctuations in the ozone record such as annual, semiannual, quasi-biennial and quasi-quadrennial oscillations. After separating the natural fluctuations from the ozone record, the trend analysis of total ozone over Cairo showed that a decrease of about -1.2% per decade has occurred since 1979.
NASA Astrophysics Data System (ADS)
Feng, Xiao-Li; Li, Yu-Xiao; Gu, Jian-Zhong; Zhuo, Yi-Zhong
2009-10-01
The relaxation property of both Eigen model and Crow-Kimura model with a single peak fitness landscape is studied from phase transition point of view. We first analyze the eigenvalue spectra of the replication mutation matrices. For sufficiently long sequences, the almost crossing point between the largest and second-largest eigenvalues locates the error threshold at which critical slowing down behavior appears. We calculate the critical exponent in the limit of infinite sequence lengths and compare it with the result from numerical curve fittings at sufficiently long sequences. We find that for both models the relaxation time diverges with exponent 1 at the error (mutation) threshold point. Results obtained from both methods agree quite well. From the unlimited correlation length feature, the first order phase transition is further confirmed. Finally with linear stability theory, we show that the two model systems are stable for all ranges of mutation rate. The Eigen model is asymptotically stable in terms of mutant classes, and the Crow-Kimura model is completely stable.
Thorat, Yogesh T; Salvi, Sundeep S; Kodgule, Rahul R
2017-05-09
Peak flow meter with questionnaire and mini-spirometer are considered as alternative tools to spirometry for screening of asthma and chronic obstructive pulmonary disease. However, the accuracy of these tools together, in clinical settings for disease diagnosis, has not been studied. Two hundred consecutive patients with respiratory complaints answered a short symptom questionnaire and performed peak expiratory flow measurements, standard spirometry with Koko spirometer and mini-spirometry (COPD-6). Spirometry was repeated after bronchodilation. Physician made a final diagnosis of asthma, chronic obstructive pulmonary disease and others. One eighty nine patients (78 females) with age 51 ± 17 years with asthma (115), chronic obstructive pulmonary disease (33) and others (41) completed the study. "Breathlessness > 6months" and "cough > 6months" were important symptoms to detect obstructive airways disease. "Asymptomatic period > 2 weeks" had the best sensitivity (Sn) and specificity (Sp) to differentiate asthma and chronic obstructive pulmonary disease. A peak expiratory flow of < 80% predicted was the best cut-off to detect airflow limitation (Sn 90%, Sp 50%). Respiratory symptoms with PEF < 80% predicted, had Sn 84 and Sp 93% to detect OAD. COPD-6 device under-estimated FEV 1 by 13 mL (95% CI: -212, 185). At a cut-off of 0.75, the FEV 1 /FEV 6 had the best accuracy (Sn 80%, Sp 86%) to detect airflow limitation. Peak flow meter with few symptom questions can be effectively used in clinical practice for objective detection of asthma and chronic obstructive pulmonary disease, in the absence of good quality spirometry. Mini-spirometers are useful in detection of obstructive airways diseases but FEV 1 measured is inaccurate. DIFFERENTIATING CONDITIONS IN POORLY-EQUIPPED SETTINGS: A simple questionnaire and peak flow meter measurements can help doctors differentiate between asthma and chronic lung disease. In clinical settings where access to specialist equipment and knowledge is limited, it can be challenging for doctors to tell the difference between asthma and chronic obstructive pulmonary disease (COPD). To determine a viable alternative method for differentiating between these diseases, Rahul Kodgule and colleagues at the Chest Research Foundation in Pune, India, trialed a simplified version of two existing symptom questionnaires, combined with peak flow meter measurements. They assessed 189 patients using this method, and found it aided diagnosis with high sensitivity and specificity. Breathlessness, cough and wheeze were the minimal symptoms required for COPD diagnosis, while the length of asymptomatic periods was most helpful in distinguishing asthma from COPD.
Zhang, Lan; Liu, Yuanhuan; Chen, Guonan
2004-07-23
A rapid, easy and reproducible capillary electrophoresis (CE) method for the simultaneous determination of allantoin, choline and arginine in Rhizoma Dioscoreae was developed first time. Under the optimum condition, the three analytes could be well separated within 5 min in a 70 cm (60 cm effective length) x 75 microm i.d. capillary. The relative standard deviations for both migration time and peak height were less than 3.20%. The linear response range was 5.0-150, 0.9-100 and 1.0-200 microg/ml for arginine, choline and allantoin, respectively. The detection limit of three components was 2.0, 0.4 and 0.5 microg/ml for arginine, choline and allantoin, respectively. Contents of arginine, choline and allantoin in the crude drug of Rhizoma Dioscoreae could be easily determined by the proposed method with satisfactory results.
Jakobsen, Simon S; Christensen, Jan H; Verdier, Sylvain; Mallet, Claude R; Nielsen, Nikoline J
2017-09-05
This work demonstrates the development of an online two-dimensional liquid chromatography (2D-LC) method where the first dimension column is eluted by a sequence of pulses of increasing eluotropic strength generated by the LC pumps (pulsed-elution 2D-LC). Between the pulses, the first dimension is kept in a no-elution state using low eluent strength. The eluate from the first dimension is actively modulated using trap columns and subsequently analyzed in the second dimension. We demonstrate that by tuning the length and eluotropic strength of the pulses, peaks with retention factors in water, k w , above 150 can be manipulated to elute in 3-4 pulses. The no-elution state can be kept for 1-10 min with only minor changes as to which and how many pulses the peaks elute in. Pulsed-elution 2D-LC combined with active modulation tackles three of the main challenges encountered in 2D-LC and specifically online comprehensive 2D-LC: undersampling, difficulties in refocusing, and lack of flexibility in the selection of column dimensions and flow rates because the two dimensions constrain each other. The pulsed-elution 2D-LC was applied for the analysis of a basic fraction of vacuum gas oil. Peak capacity was 4018 for a 540 min analysis and 4610 for a 1040 min analysis.
Deconvolution method for accurate determination of overlapping peak areas in chromatograms.
Nelson, T J
1991-12-20
A method is described for deconvoluting chromatograms which contain overlapping peaks. Parameters can be selected to ensure that attenuation of peak areas is uniform over any desired range of peak widths. A simple extension of the method greatly reduces the negative overshoot frequently encountered with deconvolutions. The deconvoluted chromatograms are suitable for integration by conventional methods.
Hydroxyapatite synthesis using EDTA
Kang, Nak Heon; Kim, Soon Je; Song, Seung Han; Choi, Sang mun; Choi, Sik Young; Kim, Youn Jung
2013-01-01
Bone comprises structure of body and is consisted of inorganic substances. It exists in an organic structure in the body. Even though it is firm and has self healing mechanism, it can be damaged by trauma, cancer, or bone diseases. Allograft can be an alternative solution for autologous bone graft. Hydroxyapatite(Ca10(PO4)6(OH)2), an excellent candidate for allograft, can be applied to bone defect area. There are several methods to produce hydroxyapatite, however economical cost and time consuming make the production difficult. In this study we synthesized the hydroxyapatite with Ethyenediamine tetraacetic acid. Freeze Dried Bone Allograft(Hans Biomed) was used to be a control group. Synthesized hydroxyapatite was a rod shape, white powdery type substance with 2 ~ 5 μm length and 0.5 ~ 1 μm width. X-ray diffraction showed the highest sharp peak at 32° and high peaks at 25.8°, 39.8°, 46.8°, 49.5°, and 64.0° indicating a similar substance to the freeze Dried Bone Allograft. 3 days after the cell growth of synthesized hydroxyapatite showed 1.5 fold more than the Bone Allograft. Cellular and media alkaline phosphate activity increased similar to the bone alloagraft. In this study we came up with a new method to produce the hydroxyapatite. It is a convenient method that can be held in room temperature and low pressure. Also the the product can be manufactured in large quantity. It can be also transformed into scaffold structure which will perform a stronger configuration. The manufacturing method will help the bony defect patients and make future medical products. PMID:23714942
Pulse position modulation for compact all-fiber vehicle laser rangefinder development
NASA Astrophysics Data System (ADS)
Mao, Xuesong; Cheng, Yongzhi; Xiong, Ying; Inoue, Daisuke; Kagami, Manabu
2017-10-01
We propose a method for developing small all-fiber vehicle laser rangefinders that is based on pulse position modulation (PPM) and data integration and present a theoretical study on its performance. Compared with spatial coupling, which is employed by most of the current commercial vehicle laser rangefinders, fiber coupling has the advantage that it can guide laser echoes into the interior of a car, so the electronic components following the photodiode can operate in a moderate-temperature environment. However, optical fibers have numerical apertures (NAs), which means that a laser beam from a receiving lens cannot be coupled into an optical fiber if its incident angle exceeds the critical value. Therefore, the effective size of the receiving lens is typically small since it is limited by its focal length and the NA of the fiber, causing the power of the laser echoes gathered by the receiving lens to be insufficient for performing target identification. Instead of increasing the peak transmitting laser power unrestrictedly, PPM and data integration effectively compensate for the low signal-to-noise ratio that results from the effective receiving lens size reduction. We validated the proposed method by conducting numerical simulations and performance analysis. Finally, we compared the proposed method with pseudorandom noise (PN) code modulation and found that, although the two methods perform equally well in single-target measurement scenarios, PPM is more effective than PN code modulation for multitarget measurement. In addition, PPM enables the transmission of laser beams with higher peak powers and requires less computation than PN code modulation does.
NASA Astrophysics Data System (ADS)
Çırak, Çağrı; Demir, Selçuk; Ucun, Fatih; Çubuk, Osman
2011-08-01
Experimental and theoretical vibrational spectra of β-2-aminopyridinium dihydrogenphosphate (β-2APDP) have been investigated. The FT-IR spectrum of β-2APDP was recorded in the region 4000-400 cm -1. The optimized molecular structure and theoretical vibrational frequencies of β-2APDP have been investigated using ab initio Hartree-Fock (HF) and density functional B3LYP method with 6-311++G(d,p) basis set. The optimized geometric parameters (bond lengths and bond angles) and theoretical frequencies have been compared with the corresponding experimental data and it is found that they agree well with each other. All the assignments of the theoretical frequencies were performed by potential energy distributions using VEDA 4 program. Furthermore, the used scale factors were obtained from the ratio of the frequency values of the strongest peaks in the experimental and theoretical IR spectra. From the results it was concluded that the B3LYP method is superior to the HF method for the vibrational frequencies.
Variations in the rotation of the earth
NASA Astrophysics Data System (ADS)
Carter, W. E.; Robertson, D. S.; Pettey, J. E.; Tapley, B. D.; Schutz, B. E.; Eanes, R. J.; Miao, L.
Variations in the earth's rotation (UTI) and length of day have been tracked at the submillisecond level by astronomical radio interferometry and laser ranging to the LAGEOS satellite. Three years of regular measurements reveal complex patterns of variations including UTI fluctuations as large as 5 milliseconds in a few weeks. Comparison of the observed changes in length of day with variations in the global atmospheric angular momentum indicates that the dominant cause of changes in the earth's spin rate, on time scales from a week to several years, is the exchange of angular momentum between the atmosphere and the mantle. The unusually intense El Nino of 1982-1983 was marked by a strong peak in the length of day.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhou, Q. G.; Chen, N.; Zhang, M.
Five IDs will be built for the Shanghai Synchrotron Radiation Facility (SSRF). Two identical mini-gap undulators with the period length 25mm and the minimum gap 6mm will use the in-vacuum technology and can operate in tapered mode. Two wigglers with the period lengths 7.9cm and 14cm and the same minimum gap 14mm will produce the peak fields of 1.2T and 1.94T. A variable polarization undulator of the APPLE-II type with 4.2m long and the period length 10cm can provide linearly, circularly and elliptically polarized radiation in a wide spectral range. This paper describes the magnet designs and the mechanical structuremore » designs of these IDs.« less
A comparison of VLBI with the ICE-3G glacial rebound model
NASA Technical Reports Server (NTRS)
James, Thomas S.; Lambert, Anthony
1993-01-01
Crustal motion predicted by the ICE-3G glacial rebound model exhibits a pattern of tangential (horizontal) divergence away from the centers of uplift, which in North America and Europe are located around Hudson Bay and the Gulf of Bothnia. Tangential velocities reach peak magnitudes of 1-2 mm/yr, and must be included when predicting VLBI baseline length change rates due to postglacial rebound. Out of 18 observed VLBI baselines examined three are situated such that their predicted length rates are around their 2 sigma uncertainties or greater. It is encouraging that two of these baselines exhibit predicted length rates within 2 sigma of the observed rates.
A wavelet-based Gaussian method for energy dispersive X-ray fluorescence spectrum.
Liu, Pan; Deng, Xiaoyan; Tang, Xin; Shen, Shijian
2017-05-01
This paper presents a wavelet-based Gaussian method (WGM) for the peak intensity estimation of energy dispersive X-ray fluorescence (EDXRF). The relationship between the parameters of Gaussian curve and the wavelet coefficients of Gaussian peak point is firstly established based on the Mexican hat wavelet. It is found that the Gaussian parameters can be accurately calculated by any two wavelet coefficients at the peak point which has to be known. This fact leads to a local Gaussian estimation method for spectral peaks, which estimates the Gaussian parameters based on the detail wavelet coefficients of Gaussian peak point. The proposed method is tested via simulated and measured spectra from an energy X-ray spectrometer, and compared with some existing methods. The results prove that the proposed method can directly estimate the peak intensity of EDXRF free from the background information, and also effectively distinguish overlap peaks in EDXRF spectrum.
Ionoacoustic characterization of the proton Bragg peak with submillimeter accuracy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Assmann, W., E-mail: walter.assmann@lmu.de; Reinhardt, S.; Lehrack, S.
2015-02-15
Purpose: Range verification in ion beam therapy relies to date on nuclear imaging techniques which require complex and costly detector systems. A different approach is the detection of thermoacoustic signals that are generated due to localized energy loss of ion beams in tissue (ionoacoustics). Aim of this work was to study experimentally the achievable position resolution of ionoacoustics under idealized conditions using high frequency ultrasonic transducers and a specifically selected probing beam. Methods: A water phantom was irradiated by a pulsed 20 MeV proton beam with varying pulse intensity and length. The acoustic signal of single proton pulses was measuredmore » by different PZT-based ultrasound detectors (3.5 and 10 MHz central frequencies). The proton dose distribution in water was calculated by Geant4 and used as input for simulation of the generated acoustic wave by the matlab toolbox k-WAVE. Results: In measurements from this study, a clear signal of the Bragg peak was observed for an energy deposition as low as 10{sup 12} eV. The signal amplitude showed a linear increase with particle number per pulse and thus, dose. Bragg peak position measurements were reproducible within ±30 μm and agreed with Geant4 simulations to better than 100 μm. The ionoacoustic signal pattern allowed for a detailed analysis of the Bragg peak and could be well reproduced by k-WAVE simulations. Conclusions: The authors have studied the ionoacoustic signal of the Bragg peak in experiments using a 20 MeV proton beam with its correspondingly localized energy deposition, demonstrating submillimeter position resolution and providing a deep insight in the correlation between the acoustic signal and Bragg peak shape. These results, together with earlier experiments and new simulations (including the results in this study) at higher energies, suggest ionoacoustics as a technique for range verification in particle therapy at locations, where the tumor can be localized by ultrasound imaging. This acoustic range verification approach could offer the possibility of combining anatomical ultrasound and Bragg peak imaging, but further studies are required for translation of these findings to clinical application.« less
Techniques for estimating flood-peak discharges of rural, unregulated streams in Ohio
Koltun, G.F.; Roberts, J.W.
1990-01-01
Multiple-regression equations are presented for estimating flood-peak discharges having recurrence intervals of 2, 5, 10, 25, 50, and 100 years at ungaged sites on rural, unregulated streams in Ohio. The average standard errors of prediction for the equations range from 33.4% to 41.4%. Peak discharge estimates determined by log-Pearson Type III analysis using data collected through the 1987 water year are reported for 275 streamflow-gaging stations. Ordinary least-squares multiple-regression techniques were used to divide the State into three regions and to identify a set of basin characteristics that help explain station-to- station variation in the log-Pearson estimates. Contributing drainage area, main-channel slope, and storage area were identified as suitable explanatory variables. Generalized least-square procedures, which include historical flow data and account for differences in the variance of flows at different gaging stations, spatial correlation among gaging station records, and variable lengths of station record were used to estimate the regression parameters. Weighted peak-discharge estimates computed as a function of the log-Pearson Type III and regression estimates are reported for each station. A method is provided to adjust regression estimates for ungaged sites by use of weighted and regression estimates for a gaged site located on the same stream. Limitations and shortcomings cited in an earlier report on the magnitude and frequency of floods in Ohio are addressed in this study. Geographic bias is no longer evident for the Maumee River basin of northwestern Ohio. No bias is found to be associated with the forested-area characteristic for the range used in the regression analysis (0.0 to 99.0%), nor is this characteristic significant in explaining peak discharges. Surface-mined area likewise is not significant in explaining peak discharges, and the regression equations are not biased when applied to basins having approximately 30% or less surface-mined area. Analyses of residuals indicate that the equations tend to overestimate flood-peak discharges for basins having approximately 30% or more surface-mined area. (USGS)
Design and implementation of low complexity wake-up receiver for underwater acoustic sensor networks
NASA Astrophysics Data System (ADS)
Yue, Ming
This thesis designs a low-complexity dual Pseudorandom Noise (PN) scheme for identity (ID) detection and coarse frame synchronization. The two PN sequences for a node are identical and are separated by a specified length of gap which serves as the ID of different sensor nodes. The dual PN sequences are short in length but are capable of combating severe underwater acoustic (UWA) multipath fading channels that exhibit time varying impulse responses up to 100 taps. The receiver ID detection is implemented on a microcontroller MSP430F5529 by calculating the correlation between the two segments of the PN sequence with the specified separation gap. When the gap length is matched, the correlator outputs a peak which triggers the wake-up enable. The time index of the correlator peak is used as the coarse synchronization of the data frame. The correlator is implemented by an iterative algorithm that uses only one multiplication and two additions for each sample input regardless of the length of the PN sequence, thus achieving low computational complexity. The real-time processing requirement is also met via direct memory access (DMA) and two circular buffers to accelerate data transfer between the peripherals and the memory. The proposed dual PN detection scheme has been successfully tested by simulated fading channels and real-world measured channels. The results show that, in long multipath channels with more than 60 taps, the proposed scheme achieves high detection rate and low false alarm rate using maximal-length sequences as short as 31 bits to 127 bits, therefore it is suitable as a low-power wake-up receiver. The future research will integrate the wake-up receiver with Digital Signal Processors (DSP) for payload detection.
Within-Event and Between-Events Ground Motion Variability from Earthquake Rupture Scenarios
NASA Astrophysics Data System (ADS)
Crempien, Jorge G. F.; Archuleta, Ralph J.
2017-09-01
Measurement of ground motion variability is essential to estimate seismic hazard. Over-estimation of variability can lead to extremely high annual hazard estimates of ground motion exceedance. We explore different parameters that affect the variability of ground motion such as the spatial correlations of kinematic rupture parameters on a finite fault and the corner frequency of the moment-rate spectra. To quantify the variability of ground motion, we simulate kinematic rupture scenarios on several vertical strike-slip faults and compute ground motion using the representation theorem. In particular, for the entire suite of rupture scenarios, we quantify the within-event and the between-events ground motion variability of peak ground acceleration (PGA) and response spectra at several periods, at 40 stations—all approximately at an equal distance of 20 and 50 km from the fault. Both within-event and between-events ground motion variability increase when the slip correlation length on the fault increases. The probability density functions of ground motion tend to truncate at a finite value when the correlation length of slip decreases on the fault, therefore, we do not observe any long-tail distribution of peak ground acceleration when performing several rupture simulations for small correlation lengths. Finally, for a correlation length of 6 km, the within-event and between-events PGA log-normal standard deviations are 0.58 and 0.19, respectively, values slightly smaller than those reported by Boore et al. (Earthq Spectra, 30(3):1057-1085, 2014). The between-events standard deviation is consistently smaller than the within-event for all correlations lengths, a feature that agrees with recent ground motion prediction equations.
Extremely High Peak Power Obtained at 29 GHZ Microwave Pulse Generation
NASA Astrophysics Data System (ADS)
Rostov, V. V.; Gunin, A. V.; Romanchenko, I. V.; Pedos, M. S.; Rukin, S. N.; Sharypov, K. A.; Shunailov, S. A.; Ul'maskulov, M. R.; Yalandin, M. I.
2017-12-01
The paper presents research results on enhancing the peak power of microwave pulses with sub- and nanosecond length using a backward-wave oscillator (BWO) operating at 29 GHz frequency and possessing a reproducible phase structure. Experiments are conducted in two modes on a high-current electron accelerator with the required electron beam power. In the first (superradiation) mode, which utilizes the elongated slow-wave structure, the BWO peak power is 3 GW at 180 ns pulse duration (full width at halfmaximum, FWHM). In the second (quasi-stationary) mode, the BWO peak power reaches 600 MW at 2 ns pulse duration (FWHM). The phase spread from pulse to pulse can vary from units to several tens of percent in a nanosecond pulse mode. The experiments do not show any influence of microwave breakdown on the BWO power generation and radiation pulse duration.
2014-06-19
excited by a sine -wave signal with peak- to-peak amplitudes between 7.2 kV and 10 kV, and frequencies of 2.5 kHz and 4 kHz. The results indicate that the...side length of 0.68 m, made of transparent PMMA, to isolate it from ambient disturbances. The plasma actuator was excited by a sine -wave signal, which... Portugal , 2008. 6Hanson, R., Houser, N., and Lavoie, P., “Dielectric material degradation monitoring of dielectric barrier discharge plasma actuators
Observations of Space Weather and Space Climate Over the Past 15 Years From SABER (And Longer!)
NASA Technical Reports Server (NTRS)
Mlynczak, Marty; Hunt, Linda; Russell, James M., III
2016-01-01
The global infrared (IR) energy budget of the thermosphere has been reconstructed back 70 years (to 1947). IR cooling, integrated over a solar cycle, is relatively constant over the 5 complete cycles (19 -23) studied. Result implies that solar energy (particles and photons) has similar, small (< 7%) variation from one cycle to next. From Earth's upper atmosphere perspective, solar cycles are really more similar than different, over their length. No consistent relationship between peak of IR cooling and sunspot number peak. Results submitted to GRL 8/2016.
Localized plasmon resonance in boron-doped multiwalled carbon nanotubes
NASA Astrophysics Data System (ADS)
Shuba, M. V.; Yuko, D. I.; Kuzhir, P. P.; Maksimenko, S. A.; Chigir, G. G.; Pyatlitski, A. N.; Sedelnikova, O. V.; Okotrub, A. V.; Lambin, Ph.
2018-05-01
Substitutionally boron-doped multiwalled carbon nanotubes (B-CNTs) with lengths mainly less than 0.5 μ m and diameters 10-30 nm have been obtained by arc-discharge evaporation of the graphite anode containing boron material. The broad peak has been observed in the midinfrared conductivity spectra of the thin film comprising B-CNTs. The peak was suggested to be associated with a phenomenon known as localized plasmon resonance. Theoretical analysis has been done to confirm the possibility of this phenomenon to occur in the B-CNTs.
Slot-coupled CW standing wave accelerating cavity
Wang, Shaoheng; Rimmer, Robert; Wang, Haipeng
2017-05-16
A slot-coupled CW standing wave multi-cell accelerating cavity. To achieve high efficiency graded beta acceleration, each cell in the multi-cell cavity may include different cell lengths. Alternatively, to achieve high efficiency with acceleration for particles with beta equal to 1, each cell in the multi-cell cavity may include the same cell design. Coupling between the cells is achieved with a plurality of axially aligned kidney-shaped slots on the wall between cells. The slot-coupling method makes the design very compact. The shape of the cell, including the slots and the cone, are optimized to maximize the power efficiency and minimize the peak power density on the surface. The slots are non-resonant, thereby enabling shorter slots and less power loss.
NASA Astrophysics Data System (ADS)
Bryzgunov, M. I.; Kamerdzhiev, V.; Li, J.; Mao, L. J.; Parkhomchuk, V. V.; Reva, V. B.; Yang, X. D.; Zhao, H.
2017-07-01
Electron cooling is used for damping both transverse and longitudinal oscillations of heavy particle. The cooling of bunch ion beam (with RF voltage on) is important part of experiments with inner target, ion collision system, stacking and RF manipulation. The short length of an ion bunch increases the peak luminosity, gives a start-time point for using of the time-of-flight methods and obtains a short extraction beam pulse. This article describes the review of last experiments with electron cooling carried out on the CSRm, CSRe (China) and COSY (Germany) storage rings. The accumulated experience may be used for the project of electron cooler on 2.5 MeV (NICA) and 0.5 MeV HIAF for obtaining high luminosity, depressing beam-beam effects and RF manipulation.
Gómez, Y; Terranova, M; Zähner, M; Hillmann, E; Savary, P
2017-02-01
Dairy cow body size has increased over time because of breeding selection for higher milk yield, but milking stall dimensions have never been adjusted and are based on the practical experience of milking-machine manufacturers and advisory institutions. Narrow, limited milking stall dimensions might lead to behavioral changes during milking due to lack of comfort. The aim of this study was to examine the current space allowance in milking stalls on dairy farms and assess the effect of space allowance on cow behavior during milking. On 15 Swiss dairy farms, we measured clear milking stall dimensions and cow body dimensions. We calculated space ratios for length (SR length ) and width (SR width ) by dividing the milking stall length or width by cow body length or belly width, respectively. When the space ratio was >1, we assumed that the body length or width of cow was smaller than the milking stall length or width. On each farm, 10 healthy cows were chosen for behavioral observation during 1 evening milking. We recorded rumination, elimination, and latency to enter the milking stall by direct observation. Hind leg activity was recorded using acceleration loggers. Data were analyzed using general linear mixed-effects models with farm as a random effect. Due to a strong collinearity between SR width and SR length , we chose SR length for further analysis, because it is based on skeletal characteristics. The SR length was smallest in side-by-side parlors (1.07 ± 0.01) and largest in tandem parlors (1.18 ± 0.01). More cows had a tendency to ruminate with increasing SR length (odds ratio: 1.8). None of hind leg activity, maximum peaks of hind leg accelerations, or latency to enter the milking stall were significantly affected by SR length . Latency to enter the milking stall was longer for group milking parlors (side-by-side: 44.0 ± 3.2 s; herringbone: 34.3 ± 2.9 s) than for tandem parlors (19.0 ± 2.7 s). Milking parlor type had no effect on hind leg activity, maximum peaks of hind leg accelerations or rumination. The SR length affected rumination behavior to some extent, indicating that cow comfort was positively affected by larger milking stall length. Because cow comfort is important for good milking performance, further investigations of milking stall dimensions for cow comfort and thus welfare are needed. Furthermore, the results showed that parlor type affected cow behavior, irrespective of SR length , making future research necessary to identify the factors leading to this effect of parlor type. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
German, U; Weinstein, M; Abraham, A; Alfassi, Z B
2007-01-01
The location of the glow peaks depends on the heating rate. It takes some time until the crystal reaches the heater temperature, and this time lag has a direct effect on the shift of peaks towards higher temperatures. Some information on the high-temperature peaks may be lost if the readout conditions (mainly length of time) are not properly chosen. Step heating profiles to a varying final temperature between 300 degrees C and 125 degrees C were used to study the time dependence of the collected information in the glow curves of (6)LiF:Mg,Ti crystals, and the minimal heating time for evaluation of thermal neutron doses was determined.
Localized surface plasmon resonance of nanotriangle dimers at different relative positions
NASA Astrophysics Data System (ADS)
Ren, Yatao; Qi, Hong; Chen, Qin; Wang, Shenling; Ruan, Liming
2017-09-01
The investigation of nanoparticle's optical properties is crucial for their biological and therapeutic applications. In the present work, a promising type of gold nanoparticle, the triangular prism which was reported to have multipolar surface plasmon peaks, was studied. The Plasmon ruler effect of nanotriangle dimers was observed and investigated for the first time. Well-defined trends of the extinction spectra maxima, which have a linear correlation with the triangle edge length, for lower order extinction corresponding to in-plane mode, were observed. On this basis, the optical property of nanotriangle dimers with different arrangements, including two nanotriangles aligned side-by-side, bottom-to-bottom, and in line, were studied. For the side-by-side arrangement, an additional peak was generated on the red shift side of the peak corresponding to dipole mode. When the distance between two prisms was scaled by the triangular side length, the relative plasmon shift can be approximated as an exponential function of the relative offset distance. Moreover, for dimers with nanotriangles arranged in line, there was a global blue shift of the extinction spectra with the approaching of two particles, including the higher order mode extinction. An interesting phenomenon was found for dimers with two nanotriangles aligned bottom-to-bottom. The resonance band split into two bands with the decreasing of the offset distance.
Kay, Anthony D; Blazevich, Anthony J
2009-04-01
The effects of static stretch on muscle and tendon mechanical properties and muscle activation were studied in fifteen healthy human volunteers. Peak active and passive moment data were recorded during plantar flexion trials on an isokinetic dynamometer. Electromyography (EMG) monitoring of the triceps surae muscles, real-time motion analysis of the lower leg, and ultrasound imaging of the Achilles-medial gastrocnemius muscle-tendon junction were simultaneously conducted. Subjects performed three 60-s static stretches before being retested 2 min and 30 min poststretch. There were three main findings in the present study. First, peak concentric moment was significantly reduced after stretch; 60% of the deficit recovered 30 min poststretch. This was accompanied by, and correlated with (r = 0.81; P < 0.01) reductions in peak triceps surae EMG amplitude, which was fully recovered at 30 min poststretch. Second, Achilles tendon length was significantly shorter during the concentric contraction after stretch and at 30 min poststretch; however, no change in tendon stiffness was detected. Third, passive joint moment was significantly reduced after stretch, and this was accompanied by significant reductions in medial gastrocnemius passive muscle stiffness; both measures fully recovered by 30 min poststretch. These data indicate that the stretching protocol used in this study induced losses in concentric moment that were accompanied by, and related to, reductions in neuromuscular activity, but they were not associated with alterations in tendon stiffness or shorter muscle operating length. Reductions in passive moment were associated with reductions in muscle stiffness, whereas tendon mechanics were unaffected by the stretch. Importantly, the impact on mechanical properties and neuromuscular activity was minimal at 30 min poststretch.
Effect of obstructive sleep apnoea on severity and short-term prognosis of acute coronary syndrome.
Barbé, Ferran; Sánchez-de-la-Torre, Alicia; Abad, Jorge; Durán-Cantolla, Joaquin; Mediano, Olga; Amilibia, Jose; Masdeu, Maria José; Florés, Marina; Barceló, Antonia; de la Peña, Mónica; Aldomá, Albina; Worner, Fernando; Valls, Joan; Castellà, Gerard; Sánchez-de-la-Torre, Manuel
2015-02-01
The goal of this study was to evaluate the influence of obstructive sleep apnoea on the severity and short-term prognosis of patients admitted for acute coronary syndrome. Obstructive sleep apnoea was defined as an apnoea-hypopnoea index (AHI) >15 h(-1). We evaluated the acute coronary syndrome severity (ejection fraction, Killip class, number of diseased vessels, and plasma peak troponin) and short-term prognosis (length of hospitalisation, complications and mortality). We included 213 patients with obstructive sleep apnoea (mean±sd AHI 30±14 h(-1), 61±10 years, 80% males) and 218 controls (AHI 6±4 h(-1), 57±12 years, 82% males). Patients with obstructive sleep apnoea exhibited a higher prevalence of systemic hypertension (55% versus 37%, p<0.001), higher body mass index (29±4 kg·m(-2) versus 26±4 kg·m(-2), p<0.001), and lower percentage of smokers (61% versus 71%, p=0.04). After adjusting for smoking, age, body mass index and hypertension, the plasma peak troponin levels were significantly elevated in the obstructive sleep apnoea group (831±908 ng·L(-1) versus 987±884 ng·L(-1), p=0.03) and higher AHI severity was associated with an increased number of diseased vessels (p=0.04). The mean length of stay in the coronary care unit was higher in the obstructive sleep apnoea group (p=0.03). This study indicates that obstructive sleep apnoea is related to an increase in the peak plasma troponin levels, number of diseased vessels, and length of stay in the coronary care unit. Copyright ©ERS 2015.
NASA Astrophysics Data System (ADS)
Kikuchi, T.
2004-12-01
The near instantaneous onset of a geomagnetic impulse such as the preliminary reverse impulse (PRI) of the geomagnetic sudden commencement at high latitude and at the dayside geomagnetic equator has been explained by means of the TM0 mode waves in the Earth-ionosphere waveguide (Kikuchi and Araki, J. Atmosph. Terrest. Phys., 41, 927-936, 1979). There is, on the other hand, a time lag of the order of 10 sec in the peak amplitude of the magnetic impulse at the dayside equator. To explain these two temporal aspects, we examine transmission of the TM0 mode in a finite-length Earth-ionosphere transmission line composed of a finitely conducting ionosphere and the perfectly conducting Earth, with a fixed electric potential at one end and null potential at the other end of the transmission line, corresponding to the foot of a field-aligned current on the dawn- or dusk-side in the polar cap and middle point on the noon-midnight meridian at low latitude, respectively. Successive transmission and reflection in the bounded transmission line lead to that the ionospheric currents start to grow instantaneously, but reach a steady state with a relaxation time proportional to the length of the transmission line and the ionospheric conductivity. The relaxation time is of the order of 10 sec when we give high conductivity applicable to the equatorial ionosphere, which matches the observed time lag in the peak amplitude of the equatorial geomagnetic impulse. Consequently, the TM0 mode in the finite-length Earth-ionosphere transmission line explains both the instantaneous onset and time lag in the peak amplitude of the geomagnetic impulse at the dayside geomagnetic equator.
Li, Yaoguo; He, Maoxian
2014-01-01
The pearl oyster, Pinctada fucata (P. fucata), is one of the marine bivalves that is predominantly cultured for pearl production. To obtain more genetic information for breeding purposes, we constructed a high-density linkage map of P. fucata and identified quantitative trait loci (QTL) for growth-related traits. One F1 family, which included the two parents, 48 largest progeny and 50 smallest progeny, was sampled to construct a linkage map using restriction site-associated DNA sequencing (RAD-Seq). With low coverage data, 1956.53 million clean reads and 86,342 candidate RAD loci were generated. A total of 1373 segregating SNPs were used to construct a sex-average linkage map. This spanned 1091.81 centimorgans (cM), with 14 linkage groups and an average marker interval of 1.41 cM. The genetic linkage map coverage, Coa, was 97.24%. Thirty-nine QTL-peak loci, for seven growth-related traits, were identified using the single-marker analysis, nonparametric mapping Kruskal-Wallis (KW) test. Parameters included three for shell height, six for shell length, five for shell width, four for hinge length, 11 for total weight, eight for soft tissue weight and two for shell weight. The QTL peak loci for shell height, shell length and shell weight were all located in linkage group 6. The genotype frequencies of most QTL peak loci showed significant differences between the large subpopulation and the small subpopulation (P<0.05). These results highlight the effectiveness of RAD-Seq as a tool for generation of QTL-targeted and genome-wide marker data in the non-model animal, P. fucata, and its possible utility in marker-assisted selection (MAS). PMID:25369421
Vallejo Casas, Juan Antonio; Mena Bares, Luisa M; Gálvez, María Angeles; Marlowe, Robert J; Latre Romero, José M; Martínez-Paredes, María
2011-09-01
We sought to empirically compare treatment room length-of-stay and patient throughput for recombinant human thyroid-stimulating hormone (rhTSH)-aided thyroid remnant ablation with thyroid hormone withdrawal (THW)-aided ablation in patients with differentiated thyroid carcinoma (DTC). We retrospectively reviewed charts of all eligible (near) totally thyroidectomized patients with DTC undergoing ablation and 1-year ablation success evaluation at our tertiary referral centre from January 2003 to February 2009 (N=274). M1 disease caused exclusion unless discovered by a postablation scan or present when rhTSH was the only tolerable stimulation method. We extracted data on the length-of-stay, defined as the time between treatment room admission and discharge, and patient throughput, defined as patients ablated per treatment room per week. The treatment room discharge criterion was a whole-body dose rate of less than 60 μSv/h at 50 cm. The treatment groups (rhTSH, n=187; THW, n=87) had mostly statistically similar characteristics, but differed in primary tumour status distribution. In addition, at ablation, the rhTSH patients had a greater prevalence of prior diagnostic scintigraphy, higher mean serum TSH, and shorter interval since surgery, and received a 5.6% larger mean ablation activity. On average, rhTSH patients had a significantly lower peak whole-body dose rate (57.1 vs. 83.4 μSv/h at 50 cm; P<0.0001) and a significantly shorter treatment room stay than did the THW patients (1.41 vs. 2.02 days; P<0.001). rhTSH use allowed significantly more patients to be ablated per room per week (2.7 vs. 1.2; P<0.001). Relative to THW, rhTSH use to aid ablation reduced mean treatment room length-of-stay by almost one-third and more than doubled the average weekly patient throughput, both of which were significant differences.
Method and apparatus for current-output peak detection
DOE Office of Scientific and Technical Information (OSTI.GOV)
De Geronimo, Gianluigi
2017-01-24
A method and apparatus for a current-output peak detector. A current-output peak detector circuit is disclosed and works in two phases. The peak detector circuit includes switches to switch the peak detector circuit from the first phase to the second phase upon detection of the peak voltage of an input voltage signal. The peak detector generates a current output with a high degree of accuracy in the second phase.
Automated touch screen device for recording complex rodent behaviors
Mabrouk, O.S.; Dripps, I.J.; Ramani, S.; Chang, C.; Han, J.L.; Rice, KC; Jutkiewicz, E.M.
2016-01-01
Background Monitoring mouse behavior is a critical step in the development of modern pharmacotherapies. New Method Here we describe the application of a novel method that utilizes a touch display computer (tablet) and software to detect, record, and report fine motor behaviors. A consumer-grade tablet device is placed in the bottom of a specially made acrylic cage allowing the animal to walk on the device (MouseTrapp). We describe its application in open field (for general locomotor studies) which measures step lengths and velocity. The device can perform light-dark (anxiety) tests by illuminating half of the screen and keeping the other half darkened. A divider is built into the lid of the device allowing the animal free access to either side. Results Treating mice with amphetamine and the delta opioid peptide receptor agonist SNC80 stimulated locomotor activity on the device. Amphetamine increased step velocity but not step length during its peak effect (40–70 min after treatment), thus indicating detection of subtle amphetamine-induced effects. Animals showed a preference (74% of time spent) for the darkened half compared to the illuminated side. Comparison with Existing Method Animals were videotaped within the chamber to compare quadrant crosses to detected motion on the device. The slope, duration and magnitude of quadrant crosses tightly correlated with overall locomotor activity as detected by Mousetrapp. Conclusions We suggest that modern touch display devices such as MouseTrapp will be an important step toward automation of behavioral analyses for characterizing phenotypes and drug effects. PMID:24952323
Waltemeyer, Scott D.
2006-01-01
Estimates of the magnitude and frequency of peak discharges are necessary for the reliable flood-hazard mapping in the Navajo Nation in Arizona, Utah, Colorado, and New Mexico. The Bureau of Indian Affairs, U.S. Army Corps of Engineers, and Navajo Nation requested that the U.S. Geological Survey update estimates of peak discharge magnitude for gaging stations in the region and update regional equations for estimation of peak discharge and frequency at ungaged sites. Equations were developed for estimating the magnitude of peak discharges for recurrence intervals of 2, 5, 10, 25, 50, 100, and 500 years at ungaged sites using data collected through 1999 at 146 gaging stations, an additional 13 years of peak-discharge data since a 1997 investigation, which used gaging-station data through 1986. The equations for estimation of peak discharges at ungaged sites were developed for flood regions 8, 11, high elevation, and 6 and are delineated on the basis of the hydrologic codes from the 1997 investigation. Peak discharges for selected recurrence intervals were determined at gaging stations by fitting observed data to a log-Pearson Type III distribution with adjustments for a low-discharge threshold and a zero skew coefficient. A low-discharge threshold was applied to frequency analysis of 82 of the 146 gaging stations. This application provides an improved fit of the log-Pearson Type III frequency distribution. Use of the low-discharge threshold generally eliminated the peak discharge having a recurrence interval of less than 1.4 years in the probability-density function. Within each region, logarithms of the peak discharges for selected recurrence intervals were related to logarithms of basin and climatic characteristics using stepwise ordinary least-squares regression techniques for exploratory data analysis. Generalized least-squares regression techniques, an improved regression procedure that accounts for time and spatial sampling errors, then was applied to the same data used in the ordinary least-squares regression analyses. The average standard error of prediction for a peak discharge have a recurrence interval of 100-years for region 8 was 53 percent (average) for the 100-year flood. The average standard of prediction, which includes average sampling error and average standard error of regression, ranged from 45 to 83 percent for the 100-year flood. Estimated standard error of prediction for a hybrid method for region 11 was large in the 1997 investigation. No distinction of floods produced from a high-elevation region was presented in the 1997 investigation. Overall, the equations based on generalized least-squares regression techniques are considered to be more reliable than those in the 1997 report because of the increased length of record and improved GIS method. Techniques for transferring flood-frequency relations to ungaged sites on the same stream can be estimated at an ungaged site by a direct application of the regional regression equation or at an ungaged site on a stream that has a gaging station upstream or downstream by using the drainage-area ratio and the drainage-area exponent from the regional regression equation of the respective region.
Growth overshoot and seasonal size changes in the skulls of two weasel species
Keicher, Lara; Wikelski, Martin; Zub, Karol; Dechmann, Dina K. N.
2017-01-01
Ontogenetic changes in mammalian skulls are complex. For a very few species (i.e. some Sorex shrews), these also include seasonally driven, bidirectional size changes within individuals, presumably to reduce energy requirements during low resource availabilities. These patterns are poorly understood, but are likely most pronounced in high-metabolic species with limited means for energy conservation. We used generalized additive models to quantify the effect of location, Julian day, age and sex on the length and depth of 512 and 847 skulls of stoat (Mustela erminea) and weasel (M. nivalis) specimens collected throughout the northern hemisphere. Skull length of both species varies between sexes and geographically, with stoat skull length positively correlated with latitude. Both species demonstrate seasonal and ontogenetic patterns, including a rare, absolute growth overshoot in juvenile braincase depth. Standardized braincase depths of both species peak in their first summer, then decrease in their first winter, followed by a remarkable regrowth that peaks again during their second summer. This seasonal pattern varies in magnitude and timing between geographical regions and the sexes, matching predictions of Dehnel's phenomenon. This suggests implications for the evolution of over-wintering strategies in mammals, justifying further research on their mechanisms and value, with implications for applied osteology research. PMID:28280592
Spatial patterns of frequent floods in Switzerland
NASA Astrophysics Data System (ADS)
Schneeberger, Klaus; Rössler, Ole; Weingartner, Rolf
2017-04-01
Information about the spatial characteristics of high and extreme streamflow is often needed for an accurate analysis of flood risk and effective co-ordination of flood related activities, such as flood defence planning. In this study we analyse the spatial dependence of frequent floods in Switzerland across different scales. Firstly, we determine the average length of high and extreme flow events for 56 runoff time series of Swiss rivers. Secondly, a dependence measure expressing the probability that streamflow peaks are as high as peaks at a conditional site is used to describe and map the spatial extend of joint occurrence of frequent floods across Switzerland. Thirdly, we apply a cluster analysis to identify groups of sites that are likely to react similarly in terms of joint occurrence of high flow events. The results indicate that a time interval with a length of 3 days seems to be most appropriate to characterise the average length of high streamflow events across spatial scales. In the main Swiss basins, high and extreme streamflows were found to be asymptotically independent. In contrast, at the meso-scale distinct flood regions, which react similarly in terms of occurrence of frequent flood, were found. The knowledge about these regions can help to optimise flood defence planning or to estimate regional flood risk properly.
Zhao, Hongbo; Chen, Yuying; Feng, Wenquan; Zhuang, Chen
2018-05-25
Inter-satellite links are an important component of the new generation of satellite navigation systems, characterized by low signal-to-noise ratio (SNR), complex electromagnetic interference and the short time slot of each satellite, which brings difficulties to the acquisition stage. The inter-satellite link in both Global Positioning System (GPS) and BeiDou Navigation Satellite System (BDS) adopt the long code spread spectrum system. However, long code acquisition is a difficult and time-consuming task due to the long code period. Traditional folding methods such as extended replica folding acquisition search technique (XFAST) and direct average are largely restricted because of code Doppler and additional SNR loss caused by replica folding. The dual folding method (DF-XFAST) and dual-channel method have been proposed to achieve long code acquisition in low SNR and high dynamic situations, respectively, but the former is easily affected by code Doppler and the latter is not fast enough. Considering the environment of inter-satellite links and the problems of existing algorithms, this paper proposes a new long code acquisition algorithm named dual-channel acquisition method based on the extended replica folding algorithm (DC-XFAST). This method employs dual channels for verification. Each channel contains an incoming signal block. Local code samples are folded and zero-padded to the length of the incoming signal block. After a circular FFT operation, the correlation results contain two peaks of the same magnitude and specified relative position. The detection process is eased through finding the two largest values. The verification takes all the full and partial peaks into account. Numerical results reveal that the DC-XFAST method can improve acquisition performance while acquisition speed is guaranteed. The method has a significantly higher acquisition probability than folding methods XFAST and DF-XFAST. Moreover, with the advantage of higher detection probability and lower false alarm probability, it has a lower mean acquisition time than traditional XFAST, DF-XFAST and zero-padding.
The trading time risks of stock investment in stock price drop
NASA Astrophysics Data System (ADS)
Li, Jiang-Cheng; Tang, Nian-Sheng; Mei, Dong-Cheng; Li, Yun-Xian; Zhang, Wan
2016-11-01
This article investigates the trading time risk (TTR) of stock investment in the case of stock price drop of Dow Jones Industrial Average (ˆDJI) and Hushen300 data (CSI300), respectively. The escape time of stock price from the maximum to minimum in a data window length (DWL) is employed to measure the absolute TTR, the ratio of the escape time to data window length is defined as the relative TTR. Empirical probability density functions of the absolute and relative TTRs for the ˆDJI and CSI300 data evidence that (i) whenever the DWL increases, the absolute TTR increases, the relative TTR decreases otherwise; (ii) there is the monotonicity (or non-monotonicity) for the stability of the absolute (or relative) TTR; (iii) there is a peak distribution for shorter trading days and a two-peak distribution for longer trading days for the PDF of ratio; (iv) the trading days play an opposite role on the absolute (or relative) TTR and its stability between ˆDJI and CSI300 data.
Cruise noise measurements of a scale model advanced ducted propulsor
NASA Technical Reports Server (NTRS)
Dittmar, James H.; Hughes, Christopher E.; Bock, Lawrence A.; Hall, David G.
1993-01-01
A scale model Advanced Ducted Propulsor (ADP) was tested in NASA Lewis Research Center's 8- by 6-Foot Wind Tunnel to obtain acoustic data at cruise conditions. The model, designed and manufactured by Pratt & Whitney Division of United Technologies, was tested with three inlet lengths. The model has 16 rotor blades and 22 stator vanes, which results in a cut-on condition with respect to rotor-stator interaction noise. Comparisons of the noise directivity of the ADP with that of a previously tested high-speed, unducted propeller showed that the ADP peak blade passing tone was about 30 dB below that of the propeller, and therefore, should not present a cabin or enroute noise problem. The maximum blade passing tone first increased with increasing helical tip Mach number, peaked, and then decreased at a higher Mach number. The ADP tests with the shortest inlet showed more noise in the inlet arc than did tests with either of the other two inlet lengths.
Crack surface roughness in three-dimensional random fuse networks
NASA Astrophysics Data System (ADS)
Nukala, Phani Kumar V. V.; Zapperi, Stefano; Šimunović, Srđan
2006-08-01
Using large system sizes with extensive statistical sampling, we analyze the scaling properties of crack roughness and damage profiles in the three-dimensional random fuse model. The analysis of damage profiles indicates that damage accumulates in a diffusive manner up to the peak load, and localization sets in abruptly at the peak load, starting from a uniform damage landscape. The global crack width scales as Wtilde L0.5 and is consistent with the scaling of localization length ξ˜L0.5 used in the data collapse of damage profiles in the postpeak regime. This consistency between the global crack roughness exponent and the postpeak damage profile localization length supports the idea that the postpeak damage profile is predominantly due to the localization produced by the catastrophic failure, which at the same time results in the formation of the final crack. Finally, the crack width distributions can be collapsed for different system sizes and follow a log-normal distribution.
Tronick, E Z; Fetters, Linda; Olson, Karen L; Chen, Yuping
2004-04-01
This study examined the effects of intrauterine cocaine exposure on the reaches of 19 exposed and 15 unexposed infants at 7 and 15 months using kinematic measures. Infants sat at a table and reached for a rattle, a toy doll, and a chair. Videotaped reaches were digitized using the Peak Performance system. Kinematic movement variables were extracted (e.g., reach duration, peak velocity, movement units, path length) and ratios computed (e.g., path length divided by number of movement units). Regardless of exposure status, reaches of older infants were faster, more direct, had fewer movement units, and covered more distance with the first movement unit. Exposed infants covered more distance per movement unit than unexposed infants, but there were no other significant differences. Reaches of exposed and unexposed infants were essentially similar. Importantly, reach parameters for these high-risk infants were similar to reach parameters for infants at lower social and biological risk. Copyright 2004 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Di Mitri, S.; Cornacchia, M.
2015-03-01
Bunch length magnetic compression is used in high-brightness linacs driving free-electron lasers (FELs) and particle colliders to increase the peak current of the injected beam. To date, it is performed in dedicated insertions made of few degrees bending magnets and the compression factor is limited by the degradation of the beam transverse emittance owing to emission of coherent synchrotron radiation (CSR). We reformulate the known concept of CSR-driven optics balance for the general case of varying bunch length and demonstrate, through analytical and numerical results, that a 500 pC charge beam can be time-compressed in a periodic 180 deg arc at 2.4 GeV beam energy and lower, by a factor of up to 45, reaching peak currents of up to 2 kA and with a normalized emittance growth at the 0.1 μ \\text{m} rad level. The proposed solution offers new schemes of beam longitudinal gymnastics; an application to an energy recovery linac driving FEL is discussed.
A Novel Micellar Electrokinetic Chromatographic Method for Separation of Metal-DDTC Complexes
Mallah, Arfana; Memon, Saima Q.; Solangi, Amber R.; Memon, Najma; Abbassi, Kulsoom; Khuhawar, Muhammad Yar
2012-01-01
Micellar electrokinetic chromatography (MEKC) was examined for the separation and determination of Mo(VI), Cr(VI), Ni(II), Pd(II), and Co(III) as diethyl dithiocarbamate (DDTC) chelates. The separation was achieved from fused silica capillary (52 cm × 75 μm id) with effective length 40 cm, background electrolyte (BGE) borate buffer pH 9.1 (25 mM), CTAB 30% (100 mM), and 1% butanol in methanol (70 : 30 : 5 v/v/v) with applied voltage of −10 kV using reverse polarity. The photodiode array detection was achieved at 225 nm. The linear calibration for each of the element was obtained within 0.16–10 μg/mL with a limit of detection (LOD) 0.005–0.0167 μg/mL. The separation and determination was repeatable with relative standard deviation (RSD) within 2.4–3.3% (n = 4) in terms of migration time and peak height/peak area. The method was applied for the determination of Mo(VI) from potatoes and almond, Ni(II) from hydrogenated vegetable oil, and Co(III) from pharmaceutical preparations with RSD within 3.9%. The results obtained were checked by standard addition and rechecked by atomic absorption spectrometry. PMID:22649320
NASA Astrophysics Data System (ADS)
Koroloff, Sophie N.; Nevzorov, Alexander A.
2017-01-01
Spectroscopic assignment of NMR spectra for oriented uniformly labeled membrane proteins embedded in their native-like bilayer environment is essential for their structure determination. However, sequence-specific assignment in oriented-sample (OS) NMR is often complicated by insufficient resolution and spectral crowding. Therefore, the assignment process is usually done by a laborious and expensive "shotgun" method involving multiple selective labeling of amino acid residues. Presented here is a strategy to overcome poor spectral resolution in crowded regions of 2D spectra by selecting resolved "seed" residues via soft Gaussian pulses inserted into spin-exchange separated local-field experiments. The Gaussian pulse places the selected polarization along the z-axis while dephasing the other signals before the evolution of the 1H-15N dipolar couplings. The transfer of magnetization is accomplished via mismatched Hartmann-Hahn conditions to the nearest-neighbor peaks via the proton bath. By optimizing the length and amplitude of the Gaussian pulse, one can also achieve a phase inversion of the closest peaks, thus providing an additional phase contrast. From the superposition of the selective spin-exchanged SAMPI4 onto the fully excited SAMPI4 spectrum, the 15N sites that are directly adjacent to the selectively excited residues can be easily identified, thereby providing a straightforward method for initiating the assignment process in oriented membrane proteins.
Compact component for integrated quantum optic processing
Sahu, Partha Pratim
2015-01-01
Quantum interference is indispensable to derive integrated quantum optic technologies (1–2). For further progress in large scale integration of quantum optic circuit, we have introduced first time two mode interference (TMI) coupler as an ultra compact component. The quantum interference varying with coupling length corresponding to the coupling ratio is studied and the larger HOM dip with peak visibility ~0.963 ± 0.009 is found at half coupling length of TMI coupler. Our results also demonstrate complex quantum interference with high fabrication tolerance and quantum visibility in TMI coupler. PMID:26584759
Magnetic Design Guidelines for Electronic Power Supplies.
1986-09-30
henries ",= peak flux density in gauss d = wire (conductor) dia in mils CM = d2 = circular mi’s Irms = RMS current in amperes Idc = DC current in...component lac = RMS ac current in the inductor f = minimum frequency in hertz L = inductance in henries Then Eac 2 16.83 x 2, x 760 x .05 10 Eac 1 168.3 x 2...duty cycle x 1/f L inductance in henries *permeability in gauss/oersted H magnetizing force in oersteds ’. i g length of air gap in cm ic length of
Classical analogues of two-photon quantum interference.
Kaltenbaek, R; Lavoie, J; Resch, K J
2009-06-19
Chirped-pulse interferometry (CPI) captures the metrological advantages of quantum Hong-Ou-Mandel (HOM) interferometry in a completely classical system. Modified HOM interferometers are the basis for a number of seminal quantum-interference effects. Here, the corresponding modifications to CPI allow for the first observation of classical analogues to the HOM peak and quantum beating. They also allow a new classical technique for generating phase super-resolution exhibiting a coherence length dramatically longer than that of the laser light, analogous to increased two-photon coherence lengths in entangled states.
The impact of signal normalization on seizure detection using line length features.
Logesparan, Lojini; Rodriguez-Villegas, Esther; Casson, Alexander J
2015-10-01
Accurate automated seizure detection remains a desirable but elusive target for many neural monitoring systems. While much attention has been given to the different feature extractions that can be used to highlight seizure activity in the EEG, very little formal attention has been given to the normalization that these features are routinely paired with. This normalization is essential in patient-independent algorithms to correct for broad-level differences in the EEG amplitude between people, and in patient-dependent algorithms to correct for amplitude variations over time. It is crucial, however, that the normalization used does not have a detrimental effect on the seizure detection process. This paper presents the first formal investigation into the impact of signal normalization techniques on seizure discrimination performance when using the line length feature to emphasize seizure activity. Comparing five normalization methods, based upon the mean, median, standard deviation, signal peak and signal range, we demonstrate differences in seizure detection accuracy (assessed as the area under a sensitivity-specificity ROC curve) of up to 52 %. This is despite the same analysis feature being used in all cases. Further, changes in performance of up to 22 % are present depending on whether the normalization is applied to the raw EEG itself or directly to the line length feature. Our results highlight the median decaying memory as the best current approach for providing normalization when using line length features, and they quantify the under-appreciated challenge of providing signal normalization that does not impair seizure detection algorithm performance.
Ajami, Shabnam; Mina, Ahmad; Nabavizadeh, Seyed Amin
2016-01-01
Objectives: To evaluate the effect of moments and the combination of forces and moments on the mechanical properties of a bracket type miniscrew, resembling engagement of a rectangular wire by three-dimensional (3D) finite element study. Materials and Methods: By solid work software (Dassaunlt systems solid works, concord, Mass), a 3D miniscrew model of 6, 8, 10 mm lengths was designed and inserted in the osseous block, consisted of the cortical, and cancellous bones. The stress distributions, maximum stresses, and deflections of the miniscrew were evaluated for all parts using ANSYS (Work Bench, 2014). Results: As the magnitudes of the load increased from 100 to 200, 400 and 800 grf-mm, the peak of stresses in the 6 mm long miniscrew were increased from 7.7 to 61.5 Mpa. The maximum values of Von Mises in the cancellous bone were tremendously lower in comparison to the cortical bone by one hundredth. As the length of the miniscrew in contact with the bone was increased, the amounts and patterns of stress distribution in the cortical bone and the miniscrew did not change significantly. Conclusions: As the moment magnitude increased, the pick stresses increased linearly. The existence of cancellous bone was not significantly responsible for the stress distribution. The pattern of stress distribution did not change by the length of the miniscrew. PMID:27127753
NASA Technical Reports Server (NTRS)
Pineda, Evan, J.; Bednarcyk, Brett, A.; Arnold, Steven, M.
2012-01-01
A mesh objective crack band model is implemented in the generalized method of cells (GMC) micromechanics model to predict failure of a composite repeating unit cell (RUC). The micromechanics calculations are achieved using the MAC/GMC core engine within the ImMAC suite of micromechanics codes, developed at the NASA Glenn Research Center. The microscale RUC is linked to a macroscale Abaqus/Standard finite element model using the FEAMAC multiscale framework (included in the ImMAC suite). The effects of the relationship between the characteristic length of the finite element and the size of the microscale RUC on the total energy dissipation of the multiscale model are investigated. A simple 2-D composite square subjected to uniaxial tension is used to demonstrate the effects of scaling the dimensions of the RUC such that the length of the sides of the RUC are equal to the characteristic length of the finite element. These results are compared to simulations where the size of the RUC is fixed, independent of the element size. Simulations are carried out for a variety of mesh densities and element shapes, including square and triangular. Results indicate that a consistent size and shape must be used to yield preserve energy dissipation across the scales.
Photoperiod and fur lengths in the arctic fox ( Alopex lagopus L.)
NASA Astrophysics Data System (ADS)
Underwood, L. S.; Reynolds, Patricia
1980-03-01
Pelage is seasonally dimorphic in the Arctic fox. During the winter, fur lengths for this species are nearly double similar values taken during the summer season. Considerable site-specific differences in fur length are noted. In general, body sites which are exposed to the environment when an Arctic fox lies in a curled position show greater fur lengths in all seasons and greater seasonal variations than body sites that are more protected during rest. Well-furred sites may tend to conserve heat during periods of inactivity, and scantily furred sites may tend to dissipate heat during periods of exercise. The growth of winter fur may compensate for the severe cold of the arctic winter. Changes in fur lengths indicate a definite pattern in spite of individual variations. During the fall months, fur lengths seem to lag behind an increasing body-to-ambient temperature gradient. Both body-to-ambient temperature gradients and fur lengths peak during December through February. From March through June, gradual environmental warming is accompanied by a decrease in average fur lengths. Thus, there appears to be a remarkable parallel between the body-to-ambient temperature gradient and the fur lengths. The growth of fur in the Arctic fox parallels annual changes in ambient temperature and photoperiod.
Hong, Yoon No Gregory; Shin, Choongsoo S
2015-12-01
Falls on stairs often result in severe injury and occur twice as frequently in women. However, gender differences in kinetics and kinematics during stair descent are unknown. Thus, this study aimed to determine whether gender differences of knee and ankle biomechanics exist in the sagittal plane during the stair-to-ground descending transition. It was hypothesized that 1) women would reveal higher ground-toe-trochanter angle and lower ground-toe length during stair-to-ground descent transition than men; and 2) women would reveal lower peak knee extension moment during stair-to-ground descent transition than men. Fifteen men and fifteen women were recruited and performed a stair descent activity. Kinetic and kinematic data were obtained using a force plate and motion capture system. The women performed the stair descent with a lower peak knee extension moment and a peak knee power at the early weight acceptance phase. The women also revealed a higher ground-toe-trochanter angle and a lower ground-toe length, which indicated a more forward position of the lower extremity relative to the toe contact point at both the initial contact and at the time of peak kinematic and kinetic events. This study found that knee and ankle kinematics and kinetics differed significantly between the genders due to differences in ground-toe-trochanter angle. Women have a different stair descending strategy that reduces the demand of the lower extremity muscle function, but this strategy seems to increase the risk of falls. Copyright © 2015 Elsevier Ltd. All rights reserved.
Dean, M. Christopher; Cole, Tim J.
2013-01-01
We explored the relationship between growth in tooth root length and the modern human extended period of childhood. Tooth roots provide support to counter chewing forces and so it is advantageous to grow roots quickly to allow teeth to erupt into function as early as possible. Growth in tooth root length occurs with a characteristic spurt or peak in rate sometime between tooth crown completion and root apex closure. Here we show that in Pan troglodytes the peak in root growth rate coincides with the period of time teeth are erupting into function. However, the timing of peak root velocity in modern humans occurs earlier than expected and coincides better with estimates for tooth eruption times in Homo erectus. With more time to grow longer roots prior to eruption and smaller teeth that now require less support at the time they come into function, the root growth spurt no longer confers any advantage in modern humans. We suggest that a prolonged life history schedule eventually neutralised this adaptation some time after the appearance of Homo erectus. The root spurt persists in modern humans as an intrinsic marker event that shows selection operated, not primarily on tooth tissue growth, but on the process of tooth eruption. This demonstrates the overarching influence of life history evolution on several aspects of dental development. These new insights into tooth root growth now provide an additional line of enquiry that may contribute to future studies of more recent life history and dietary adaptations within the genus Homo. PMID:23342167
Surgical Risks Associated with Winter Sport Tourism
Sanchez, Stéphane; Payet, Cécile; Lifante, Jean-Christophe; Polazzi, Stéphanie; Chollet, François; Carty, Matthew J; Duclos, Antoine
2015-01-01
Background Mass tourism during winter in mountain areas may cause significant clustering of body injuries leading to increasing emergency admissions at hospital. We aimed at assessing if surgical safety and efficiency was maintained in this particular context. Methods We selected all emergency admissions of open surgery performed in French hospitals between 2010 and 2012. After identifying mountain areas with increasing volume of surgical stays during winter, we considered seasonal variations in surgical outcomes using a difference-in-differences study design. We computed multilevel regressions to evaluate whether significant increase in emergency cases had an effect on surgical mortality, complications and length of stay. Clustering effect of patients within hospitals was integrated in analysis and surgical outcomes were adjusted for both patient and hospital characteristics. Results A total of 381 hospitals had 559,052 inpatient stays related to emergency open surgery over 3 years. Compared to other geographical areas, a significant peak of activity was noted during winter in mountainous hospitals (Alps, Pyrenees, Vosges), ranging 6-77% volume increase. Peak was mainly explained by tourists’ influx (+124.5%, 4,351/3,496) and increased need for orthopaedic procedures (+36.8%, 4,731/12,873). After controlling for potential confounders, patients did not experience increased risk for postoperative death (ratio of OR 1.01, 95%CI 0.89-1.14, p = 0.891), thromboembolism (0.95, 0.77-1.17, p = 0.621) or sepsis (0.98, 0.85-1.12, p = 0.748). Length of stay was unaltered (1.00, 0.99-1.02, p = 0.716). Conclusion Surgical outcomes are not compromised during winter in French mountain areas despite a substantial influx of major emergencies. PMID:25970625
Soltani, Ghasem; Abbasi Tashnizi, Mohammad; Moeinipour, Ali Asghar; Ganjifard, Mahmoud; Esfahanizadeh, Jamil; Sepehri Shamloo, Alireza; Purafzali Firuzabadi, Seyed Javad; Zirak, Nahid
2013-01-01
Background Cardiac surgery under Cardiopulmonary bypass causes a systemic inflammatory response with a multifactorial etiology including direct tissue damage, ischemia and stimulation of immune system induced by cardiopulmonary bypass. This study was designed due to the high prevalence and complications of this stimulated immune system in mortality, morbidity, length of ICU stay, and mechanical ventilation. Objectives This study was aimed to compare preoperative and intraoperative methylprednisolone (MP) to intraoperative MP alone with respect to postbypass inflammation and clinical outcome. Patients and Methods Sixty pediatric patients (age < 5years) undergoing cardiopulmonary bypass surgery between September 2011-2012 at Imam Reza hospital-Mashhad were randomly assigned to receive preoperative and intraoperative MP (group 1: 30 mg/kg, 4 hours before bypass and in bypass prime, n = 30) or intraoperative MP only (group 2: 30 mg/kg, n = 30). Postoperative temperature (peak temperature and average temperature during the first 24 hours), amount of inotropic, duration of mechanical ventilation, ICU stay, WBC, BUN, creatinine, and CRP were recorded and compared in both groups. Data were analyzed with SPSS version 13 by T-test, Mann-Whitney test if necessary, and Chi-squared distribution. Results Patient characteristics including age, weight, gender, and duration of bypass were almost similar in both groups (P > 0.05). No significant difference in amount of inotropic medications used for hemodynamic supports, duration of mechanical ventilation, peak and average temperature and length of ICU stay was observed. Among the laboratory tests (WBC, BUN, creatinine, CRP) only WBC counts raised more in group 2 when compared to group 1(P < 0.05). Conclusions There was no difference in clinical outcome after cardiac surgery when we administered an additional dose of methylprednisolone compared to a single dose of methylprednisolone. PMID:24349746
Fused Traditional and Geometric Morphometrics Demonstrate Pinniped Whisker Diversity
Ginter, Carly C.; DeWitt, Thomas J.; Fish, Frank E.; Marshall, Christopher D.
2012-01-01
Vibrissae (whiskers) are important components of the mammalian tactile sensory system, and primarily function as detectors of vibrotactile information from the environment. Pinnipeds possess the largest vibrissae among mammals and their vibrissal hair shafts demonstrate a diversity of shapes. The vibrissae of most phocid seals exhibit a beaded morphology with repeating sequences of crests and troughs along their length. However, there are few detailed analyses of pinniped vibrissal morphology, and these are limited to a few species. Therefore, we comparatively characterized differences in vibrissal hair shaft morphologies among phocid species with a beaded profile, phocid species with a smooth profile, and otariids with a smooth profile using traditional and geometric morphometric methods. Traditional morphometric measurements (peak-to-peak distance, crest width, trough width and total length) were collected using digital photographs. Elliptic Fourier analysis (geometric morphometrics) was used to quantify the outlines of whole vibrissae. The traditional and geometric morphometric datasets were subsequently combined by mathematically scaling each to true rank, followed by a single eigendecomposition. Quadratic discriminant function analysis demonstrated that 79.3, 97.8 and 100% of individuals could be correctly classified to their species based on vibrissal shape variables in the traditional, geometric and combined morphometric analyses, respectively. Phocids with beaded vibrissae, phocids with smooth vibrissae, and otariids each occupied distinct morphospace in the geometric morphometric and combined data analyses. Otariids split into two groups in the geometric morphometric analysis and gray seals appeared intermediate between beaded- and smooth-whiskered species in the traditional and combined analyses. Vibrissal hair shafts modulate the transduction of environmental stimuli to the mechanoreceptors in the follicle-sinus complex (F-SC), which results in vibrotactile reception, but it is currently unclear how the diversity of shapes affects environmental signal modulation. PMID:22509310
NASA Technical Reports Server (NTRS)
Widrick, Jeffrey J.; Bangart, Jill J.; Karhanek, Miloslav; Fitts, Robert H.
1996-01-01
This study examined the effectiveness of intermittent weight bearing (IWB) as a countermeasure to non-weight-bearing (NWB)-induced alterations in soleus type 1 fiber force (in mN), tension (P(sub o); force per fiber cross-sectional area in kN/sq m), and maximal unloaded shortening velocity (V(sub o), in fiber lengths/s). Adult rats were assigned to one of the following groups: normal weight bearing (WB), 14 days of hindlimb NWB (NWB group), and 14 days of hindlimb NWB with IWB treatments (IWB group). The IWB treatment consisted of four 10-min periods of standing WB each day. Single, chemically permeabilized soleus fiber segments were mounted between a force transducer and position motor and were studied at maximal Ca(2+) activation, after which type 1 fiber myosin heavy-chain composition was confirmed by sodium dodecyl sulfate-polyacrylamide gel electrophoresis. NWB resulted in a loss in relative soleus mass (-45%), with type 1 fibers displaying reductions in diameter (-28%) and peak isometric force (-55%) and an increase in V(sub o) (+33%). In addition, NWB induced a 16% reduction in type 1 fiber P., a 41% reduction in type 1 fiber peak elastic modulus [E(sub o), defined as ((delta)force/(delta)length x (fiber length/fiber cross-sectional area] and a significant increase in the P(sub o)/E(sub o) ratio. In contrast to NWB, IWB reduced the loss of relative soleus mass (by 22%) and attenuated alterations in type 1 fiber diameter (by 36%), peak force (by 29%), and V(sub o)(by 48%) but had no significant effect on P(sub o), E(sub o) or P(sub o)/E(sub o). These results indicate that a modest restoration of WB activity during 14 days of NWB is sufficient to attenuate type 1 fiber atrophy and to partially restore type 1 peak isometric force and V(sub o) to WB levels. However, the NWB-induced reductions in P(sub o) and E(sub o) which we hypothesize to be due to a decline in the number and stiffness of cross bridges, respectively, are considerably less responsive to this countermeasure treatment.
Chapple, W D
1997-09-01
Reflex activation of the ventral superficial muscles (VSM) in the abdomen of the hermit crab, Pagurus pollicarus, was studied using sinusoidal and stochastic longitudinal vibration of the muscle while recording the length and force of the muscle and the spike times of three exciter motoneurons. In the absence of vibration, the interspike interval histograms of the two larger motoneurons were bimodal; cutting sensory nerves containing most of the mechanoreceptor input removed the short interval peak in the histogram, indicating that the receptors are important in maintaining tonic firing. Vibration of the muscle evoked a reflex increase in motoneuron frequency that habituated after an initial peak but remained above control levels for the duration of stimulation. Motoneuron frequency increased with root mean square (rms) stimulus amplitude. Average stiffness during stimulation was about two times the stiffness of passive muscle. The reflex did not alter muscle dynamics. Estimated transfer functions were calculated from the fast Fourier transform of length and force signals. Coherence was >0.9 for the frequency range of 3-35 Hz. Stiffness magnitude gradually increased over this range in both reflex activated and passive muscle; phase was between 10 and 20 degrees. Reflex stiffness decreased with increasing stimulus amplitudes, but at larger amplitudes, this decrease was much less pronounced; in this range stiffness was regulated by the reflex. The sinusoidal frequency at which reflex bursts were elicited was approximately 6 Hz, consistent with previous measurements using ramp stretch. During reflex excitation, there was an increase in amplitude of the short interval peak in the interspike interval histogram; this was reduced when the majority of afferent pathways was removed. A phase histogram of motoneuron firing during sinusoidal vibration had a peak at approximately 110 ms, also suggesting that an important component of the reflex is via direct projections from the mechanoreceptors. These results are consistent with the hypothesis that a robust feedforward regulation of abdominal stiffness during continuous disturbances is achieved by mechanoreceptors signalling the absolute value of changing forces; habituation of the reflex, its high-threshold for low frequency disturbances and the activation kinetics of the muscle further modify reflex dynamics.
Stimulus-dependent modulation of spike burst length in cat striate cortical cells.
DeBusk, B C; DeBruyn, E J; Snider, R K; Kabara, J F; Bonds, A B
1997-07-01
Burst activity, defined by groups of two or more spikes with intervals of < or = 8 ms, was analyzed in responses to drifting sinewave gratings elicited from striate cortical neurons in anesthetized cats. Bursting varied broadly across a population of 507 simple and complex cells. Half of this population had > or = 42% of their spikes contained in bursts. The fraction of spikes in bursts did not vary as a function of average firing rate and was stationary over time. Peaks in the interspike interval histograms were found at both 3-5 ms and 10-30 ms. In many cells the locations of these peaks were independent of firing rate, indicating a quantized control of firing behavior at two different time scales. The activity at the shorter time scale most likely results from intrinsic properties of the cell membrane, and that at the longer scale from recurrent network excitation. Burst frequency (bursts per s) and burst length (spikes per burst) both depended on firing rate. Burst frequency was essentially linear with firing rate, whereas burst length was a nonlinear function of firing rate and was also governed by stimulus orientation. At a given firing rate, burst length was greater for optimal orientations than for nonoptimal orientations. No organized orientation dependence was seen in bursts from lateral geniculate nucleus cells. Activation of cortical contrast gain control at low response amplitudes resulted in no burst length modulation, but burst shortening at optimal orientations was found in responses characterized by supersaturation. At a given firing rate, cortical burst length was shortened by microinjection of gamma-aminobutyric acid (GABA), and bursts became longer in the presence of N-methyl-bicuculline, a GABA(A) receptor blocker. These results are consistent with a model in which responses are reduced at nonoptimal orientations, at least in part, by burst shortening that is mediated by GABA. A similar mechanism contributes to response supersaturation at high contrasts via recruitment of inhibitory responses that are tuned to adjacent orientations. Burst length modulation can serve as a form of coding by supporting dynamic, stimulus-dependent reorganization of the effectiveness of individual network connections.
Reduction of chemical formulas from the isotopic peak distributions of high-resolution mass spectra.
Roussis, Stilianos G; Proulx, Richard
2003-03-15
A method has been developed for the reduction of the chemical formulas of compounds in complex mixtures from the isotopic peak distributions of high-resolution mass spectra. The method is based on the principle that the observed isotopic peak distribution of a mixture of compounds is a linear combination of the isotopic peak distributions of the individual compounds in the mixture. All possible chemical formulas that meet specific criteria (e.g., type and number of atoms in structure, limits of unsaturation, etc.) are enumerated, and theoretical isotopic peak distributions are generated for each formula. The relative amount of each formula is obtained from the accurately measured isotopic peak distribution and the calculated isotopic peak distributions of all candidate formulas. The formulas of compounds in simple spectra, where peak components are fully resolved, are rapidly determined by direct comparison of the calculated and experimental isotopic peak distributions. The singular value decomposition linear algebra method is used to determine the contributions of compounds in complex spectra containing unresolved peak components. The principles of the approach and typical application examples are presented. The method is most useful for the characterization of complex spectra containing partially resolved peaks and structures with multiisotopic elements.
Phased laser array with tailored spectral and coherence properties
Messerly, Michael J [Danville, CA; Dawson, Jay W [Livermore, CA; Beach, Raymond J [Livermore, CA
2011-03-29
Architectures for coherently combining an array of fiber-based lasers are provided. By matching their lengths to within a few integer multiples of a wavelength, the spatial and temporal properties of a single large laser are replicated, while extending the average or peak pulsed power limit.
Phased laser array with tailored spectral and coherence properties
Messerly, Michael J; Dawson, Jay W; Beach, Raymond J
2014-05-20
Architectures for coherently combining an array of fiber-based lasers are provided. By matching their lengths to within a few integer multiples of a wavelength, the spatial and temporal properties of a single large laser are replicated, while extending the average or peak pulsed power limit.
Ikematsu, H; Nabeshima, A; Yamaga, S; Yamaji, K; Kakuda, K; Ueno, K; Hayashi, J; Shirai, T; Hara, H; Kashiwagi, S
1997-06-01
To investigate the clinical implication of peak body temperature, peripheral blood white blood cell (WBC) count, and serum C-reactive protein (CRP) level in febrile symptoms among geriatric hospitalized patients, they were analyzed in 968 febrile episodes obtained from 433 hospitalized patients in the referred hospital. Episodes of one day duration were most frequent (41.6%). WBC count was elevated over 8000/microliters in 475 episodes (49.1%) and CRP exceeded 1.0 mg/dl in 770 episodes (79.5%). Frequency of WBC elevation decreased and frequency of CRP elevation increased according to the time course. The mean value of CRP increased significantly according to the time course. The frequency of WBC count increase and CRP elevation and their averages correlated to the peak body temperature. The peak body temperature displayed the most striking correlation to the length of febrile episodes among three clinical indicators, peak body temperature, WBC count, and CRP level. These results indicate that the elevation of WBC count and/or CRP level is frequent in geriatric patients with febrile symptoms. Peak body temperature may serve as a clinical indicator of the severy of the febrile disease occurring in geriatric patients.
Simulation study of the sub-terawatt laser wakefield acceleration operated in self-modulated regime
NASA Astrophysics Data System (ADS)
Hsieh, C.-Y.; Lin, M.-W.; Chen, S.-H.
2018-02-01
Laser wakefield acceleration (LWFA) can be accomplished by introducing a sub-terawatt (TW) laser pulse into a thin, high-density gas target. In this way, the self-focusing effect and the self-modulation that happened on the laser pulse produce a greatly enhanced laser peak intensity that can drive a nonlinear plasma wave to accelerate electrons. A particle-in-cell model is developed to study sub-TW LWFA when a 0.6-TW laser pulse interacts with a dense hydrogen plasma. Gas targets having a Gaussian density profile or a flat-top distribution are defined for investigating the properties of sub-TW LWFA when conducting with a gas jet or a gas cell. In addition to using 800-nm laser pulses, simulations are performed with 1030-nm laser pulses, as they represent a viable approach to realize the sub-TW LWFA driven by high-frequency, diode-pumped laser systems. The peak density which allows the laser peak power PL˜2 Pc r of self-focusing critical power is favourable for conducting sub-TW LWFA. Otherwise, an excessively high peak density can induce an undesired filament effect which rapidly disintegrates the laser field envelope and violates the process of plasma wave excitation. The plateau region of a flat-top density distribution allows the self-focusing and the self-modulation of the laser pulse to develop, from which well-established plasma bubbles can be produced to accelerate electrons. The process of electron injection is complicated in such high-density plasma conditions; however, increasing the length of the plateau region represents a straightforward method to realize the injection and acceleration of electrons within the first bubble, such that an improved LWFA performance can be accomplished.
Lei, M H; Chen, J J; Ko, Y L; Cheng, J J; Kuan, P; Lien, W P
1995-01-01
This study assessed the usefulness of continuous wave Doppler echocardiography and color flow mapping in evaluating pulmonary regurgitation (PR) and estimating pulmonary artery (PA) pressure. Forty-three patients were examined, and high quality Doppler spectral recordings of PR were obtained in 32. All patients underwent cardiac catheterization, and simultaneous PA and right ventricular (RV) pressures were recorded in 17. Four Doppler regurgitant flow velocity patterns were observed: pandiastolic plateau, biphasic, peak and plateau, and early diastolic triangular types. The peak diastolic and end-diastolic PA-to-RV pressure gradients derived from the Doppler flow profiles correlated well with the catheter measurements (r = 0.95 and r = 0.95, respectively). As PA pressure increased, the PR flow velocity became higher; a linear relationship between either systolic or mean PA pressure and Doppler-derived peak diastolic pressure gradient was noted (r = 0.90 and 0.94, respectively). Based on peak diastolic gradients of < 15, 15-30 or > 30 mm Hg, patients could be separated as those with mild, moderate or severe pulmonary hypertension, respectively (p < 0.05). A correlation was also observed between PA diastolic pressure and Doppler-derived end-diastolic pressure gradient (r = 0.91). Moreover, the Doppler velocity decay slope of PR closely correlated with that derived from the catheter method (r = 0.98). The decay slope tended to be steeper with the increment in regurgitant jet area and length obtained from color flow mapping. In conclusion, continuous wave Doppler evaluation of PR is a useful means for noninvasive estimation of PA pressure, and the Doppler velocity decay slope seems to reflect the severity of PR.
Maximum shortening velocity of lymphatic muscle approaches that of striated muscle.
Zhang, Rongzhen; Taucer, Anne I; Gashev, Anatoliy A; Muthuchamy, Mariappan; Zawieja, David C; Davis, Michael J
2013-11-15
Lymphatic muscle (LM) is widely considered to be a type of vascular smooth muscle, even though LM cells uniquely express contractile proteins from both smooth muscle and cardiac muscle. We tested the hypothesis that LM exhibits an unloaded maximum shortening velocity (Vmax) intermediate between that of smooth muscle and cardiac muscle. Single lymphatic vessels were dissected from the rat mesentery, mounted in a servo-controlled wire myograph, and subjected to isotonic quick release protocols during spontaneous or agonist-evoked contractions. After maximal activation, isotonic quick releases were performed at both the peak and plateau phases of contraction. Vmax was 0.48 ± 0.04 lengths (L)/s at the peak: 2.3 times higher than that of mesenteric arteries and 11.4 times higher than mesenteric veins. In cannulated, pressurized lymphatic vessels, shortening velocity was determined from the maximal rate of constriction [rate of change in internal diameter (-dD/dt)] during spontaneous contractions at optimal preload and minimal afterload; peak -dD/dt exceeded that obtained during any of the isotonic quick release protocols (2.14 ± 0.30 L/s). Peak -dD/dt declined with pressure elevation or activation using substance P. Thus, isotonic methods yielded Vmax values for LM in the mid to high end (0.48 L/s) of those the recorded for phasic smooth muscle (0.05-0.5 L/s), whereas isobaric measurements yielded values (>2.0 L/s) that overlapped the midrange of values for cardiac muscle (0.6-3.3 L/s). Our results challenge the dogma that LM is classical vascular smooth muscle, and its unusually high Vmax is consistent with the expression of cardiac muscle contractile proteins in the lymphatic vessel wall.
Kempka, Martin; Sjödahl, Johan; Björk, Anders; Roeraade, Johan
2004-01-01
A method for peak picking for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) is described. The method is based on the assumption that two sets of ions are formed during the ionization stage, which have Gaussian distributions but different velocity profiles. This gives rise to a certain degree of peak skewness. Our algorithm deconvolutes the peak and utilizes the fast velocity, bulk ion distribution for peak picking. Evaluation of the performance of the new method was conducted using peptide peaks from a bovine serum albumin (BSA) digest, and compared with the commercial peak-picking algorithms Centroid and SNAP. When using the new two-Gaussian algorithm, for strong signals the mass accuracy was equal to or marginally better than the results obtained from the commercial algorithms. However, for weak, distorted peaks, considerable improvement in both mass accuracy and precision was obtained. This improvement should be particularly useful in proteomics, where a lack of signal strength is often encountered when dealing with weakly expressed proteins. Finally, since the new peak-picking method uses information from the entire signal, no adjustments of parameters related to peak height have to be made, which simplifies its practical use. Copyright 2004 John Wiley & Sons, Ltd.
Data Dependent Peak Model Based Spectrum Deconvolution for Analysis of High Resolution LC-MS Data
2015-01-01
A data dependent peak model (DDPM) based spectrum deconvolution method was developed for analysis of high resolution LC-MS data. To construct the selected ion chromatogram (XIC), a clustering method, the density based spatial clustering of applications with noise (DBSCAN), is applied to all m/z values of an LC-MS data set to group the m/z values into each XIC. The DBSCAN constructs XICs without the need for a user defined m/z variation window. After the XIC construction, the peaks of molecular ions in each XIC are detected using both the first and the second derivative tests, followed by an optimized chromatographic peak model selection method for peak deconvolution. A total of six chromatographic peak models are considered, including Gaussian, log-normal, Poisson, gamma, exponentially modified Gaussian, and hybrid of exponential and Gaussian models. The abundant nonoverlapping peaks are chosen to find the optimal peak models that are both data- and retention-time-dependent. Analysis of 18 spiked-in LC-MS data demonstrates that the proposed DDPM spectrum deconvolution method outperforms the traditional method. On average, the DDPM approach not only detected 58 more chromatographic peaks from each of the testing LC-MS data but also improved the retention time and peak area 3% and 6%, respectively. PMID:24533635
Cunningham, Daniel J.; Shearer, David A.; Carter, Neil; Drawer, Scott; Pollard, Ben; Bennett, Mark; Eager, Robin; Cook, Christian J.; Farrell, John; Russell, Mark
2018-01-01
The assessment of competitive movement demands in team sports has traditionally relied upon global positioning system (GPS) analyses presented as fixed-time epochs (e.g., 5–40 min). More recently, presenting game data as a rolling average has become prevalent due to concerns over a loss of sampling resolution associated with the windowing of data over fixed periods. Accordingly, this study compared rolling average (ROLL) and fixed-time (FIXED) epochs for quantifying the peak movement demands of international rugby union match-play as a function of playing position. Elite players from three different squads (n = 119) were monitored using 10 Hz GPS during 36 matches played in the 2014–2017 seasons. Players categorised broadly as forwards and backs, and then by positional sub-group (FR: front row, SR: second row, BR: back row, HB: half back, MF: midfield, B3: back three) were monitored during match-play for peak values of high-speed running (>5 m·s-1; HSR) and relative distance covered (m·min-1) over 60–300 s using two types of sample-epoch (ROLL, FIXED). Irrespective of the method used, as the epoch length increased, values for the intensity of running actions decreased (e.g., For the backs using the ROLL method, distance covered decreased from 177.4 ± 20.6 m·min-1 in the 60 s epoch to 107.5 ± 13.3 m·min-1 for the 300 s epoch). For the team as a whole, and irrespective of position, estimates of fixed effects indicated significant between-method differences across all time-points for both relative distance covered and HSR. Movement demands were underestimated consistently by FIXED versus ROLL with differences being most pronounced using 60 s epochs (95% CI HSR: -6.05 to -4.70 m·min-1, 95% CI distance: -18.45 to -16.43 m·min-1). For all HSR time epochs except one, all backs groups increased more (p < 0.01) from FIXED to ROLL than the forward groups. Linear mixed modelling of ROLL data highlighted that for HSR (except 60 s epoch), SR was the only group not significantly different to FR. For relative distance covered all other position groups were greater than the FR (p < 0.05). The FIXED method underestimated both relative distance (~11%) and HSR values (up to ~20%) compared to the ROLL method. These differences were exaggerated for the HSR variable in the backs position who covered the greatest HSR distance; highlighting important consideration for those implementing the FIXED method of analysis. The data provides coaches with a worst-case scenario reference on the running demands required for periods of 60–300 s in length. This information offers novel insight into game demands and can be used to inform the design of training games to increase specificity of preparation for the most demanding phases of matches. PMID:29621279
Derrick, Timothy R; Edwards, W Brent; Fellin, Rebecca E; Seay, Joseph F
2016-02-08
The purpose of this research was to utilize a series of models to estimate the stress in a cross section of the tibia, located 62% from the proximal end, during walking. Twenty-eight male, active duty soldiers walked on an instrumented treadmill while external force data and kinematics were recorded. A rigid body model was used to estimate joint moments and reaction forces. A musculoskeletal model was used to gather muscle length, muscle velocity, moment arm and orientation information. Optimization procedures were used to estimate muscle forces and finally internal bone forces and moments were applied to an inhomogeneous, subject specific bone model obtained from CT scans to estimate stress in the bone cross section. Validity was assessed by comparison to stresses calculated from strain gage data in the literature and sensitivity was investigated using two simplified versions of the bone model-a homogeneous model and an ellipse approximation. Peak compressive stress occurred on the posterior aspect of the cross section (-47.5 ± 14.9 MPa). Peak tensile stress occurred on the anterior aspect (27.0 ± 11.7 MPa) while the location of peak shear was variable between subjects (7.2 ± 2.4 MPa). Peak compressive, tensile and shear stresses were within 0.52 MPa, 0.36 MPa and 3.02 MPa respectively of those calculated from the converted strain gage data. Peak values from a inhomogeneous model of the bone correlated well with homogeneous model (normal: 0.99; shear: 0.94) as did the normal ellipse model (r=0.89-0.96). However, the relationship between shear stress in the inhomogeneous model and ellipse model was less accurate (r=0.64). The procedures detailed in this paper provide a non-invasive and relatively quick method of estimating cross sectional stress that holds promise for assessing injury and osteogenic stimulus in bone during normal physical activity. Copyright © 2016 Elsevier Ltd. All rights reserved.
Jones, Drew R; Wu, Zhiping; Chauhan, Dharminder; Anderson, Kenneth C; Peng, Junmin
2014-04-01
Global metabolomics relies on highly reproducible and sensitive detection of a wide range of metabolites in biological samples. Here we report the optimization of metabolome analysis by nanoflow ultraperformance liquid chromatography coupled to high-resolution orbitrap mass spectrometry. Reliable peak features were extracted from the LC-MS runs based on mandatory detection in duplicates and additional noise filtering according to blank injections. The run-to-run variation in peak area showed a median of 14%, and the false discovery rate during a mock comparison was evaluated. To maximize the number of peak features identified, we systematically characterized the effect of sample loading amount, gradient length, and MS resolution. The number of features initially rose and later reached a plateau as a function of sample amount, fitting a hyperbolic curve. Longer gradients improved unique feature detection in part by time-resolving isobaric species. Increasing the MS resolution up to 120000 also aided in the differentiation of near isobaric metabolites, but higher MS resolution reduced the data acquisition rate and conferred no benefits, as predicted from a theoretical simulation of possible metabolites. Moreover, a biphasic LC gradient allowed even distribution of peak features across the elution, yielding markedly more peak features than the linear gradient. Using this robust nUPLC-HRMS platform, we were able to consistently analyze ~6500 metabolite features in a single 60 min gradient from 2 mg of yeast, equivalent to ~50 million cells. We applied this optimized method in a case study of drug (bortezomib) resistant and drug-sensitive multiple myeloma cells. Overall, 18% of metabolite features were matched to KEGG identifiers, enabling pathway enrichment analysis. Principal component analysis and heat map data correctly clustered isogenic phenotypes, highlighting the potential for hundreds of small molecule biomarkers of cancer drug resistance.
Williams III, D. S. Blaise; Welch, Lee M.
2015-01-01
ABSTRACT Background: Injuries to runners are common. However, there are many potential contributing factors to injury. While lack of flexibility alone is commonly related to injury, there are clear differences in hamstring flexibility between males and females. Objective: To compare the effect of static hamstring length on sagittal plane mechanics between male and female runners. Method: Forty subjects (30.0±6.4 years) participated and were placed in one of 4 groups: flexible males (n=10), inflexible males (n=10), flexible females (n=10), and inflexible females (n=10). All subjects were free of injury at the time of data collection. Three-dimensional kinematics and kinetics were collected while subjects ran over ground across 2 force platforms. Sagittal plane joint angles and moments were calculated at the knee and hip and compared with a 2-way (sex X flexibility) ANOVA (α=0.05). Results: Males exhibited greater peak knee extension moment than females (M=2.80±0.47, F=2.48±0.52 Nm/kg*m, p=0.05) and inflexible runners exhibited greater peak knee extension moment than flexible runners (In=2.83±0.56, Fl=2.44±0.51 Nm/kg*m, p=0.01). For hip flexion at initial contact, a significant interaction existed (p<0.05). Flexible females (36.7±7.4º) exhibited more hip flexion than inflexible females (27.9±4.6º, p<0.01) and flexible males (30.1±9.5º, p<0.05). No differences existed for knee angle at initial contact, peak knee angle, peak hip angle, or peak hip moment. Conclusion: Hamstring flexibility results in different mechanical profiles in males and females. Flexibility in the hamstrings may result in decreased moments via active or passive tension. These differences may have implications for performance and injury in flexible female runners. PMID:26537812
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pitton, Michael Bernhard, E-mail: pitton@radiologie.klinik.uni-mainz.de; Schmenger, Patrick; Dueber, Christoph
Purpose: To investigate pressure and maximum rate of rise of systolic pressure (peak dP/dt) in completely excluded aneurysms and endoleaks to determine the hemodynamic impact of endoleaks. Methods: In mongrel dogs (n =36) experimental aneurysms were created by insertion of a patch (portion of rectus abdomen is muscle sheath) into the infrarenalaorta. In group I (n 18), all aortic branches of the aneurysm were ligated and all aneurysms were completely excluded by stent grafts. Group II (n = 18) consisted of aneurysms with patent aortic side branches that represented sources of endoleaks.One week (n = 12), six weeks (n =more » 12),and six months (n = 12) after stent grafting,hemodynamic measurements were obtained in thrombosed aneurysms and proved endoleaks. Systemic blood pressure and intraaneurysmal pressure were simultaneously measured and the respective peak dP/dt were computed. Results: At the six-month follow-up, the systolic-pressure ratio (intraaneurysmatic pressure: systemic pressure)was significantly increased in endoleaks compared to non-perfused areas(0.879 {+-} 0.042 versus 0.438 {+-} 0.176, p <0.01, group II) or completely excluded aneurysms (0.385 {+-}0.221, group I). Peak dP/dt ratio (intraaneurysmal peak dP/dt: systemic peak dP/dt) was 0.922 {+-} 0.154 in endoleaks, compared to 0.084 {+-} 0.080 in non-perfused areas (group II, p <0.01), and was 0.146 {+-} 0.121 in completely excluded aneurysms (group I). The diastolic-pressure ratio was also increased inendoleaks compared to non-perfused areas (0.929 {+-} 0.088 versus 0.655 {+-} 0.231, p < 0.01, group II) or completely excluded aneurysms (0.641 {+-} 0.278, group I). In excluded aneurysms, pressure exposure declined as the length of the follow-up period increased. Conclusion: Type II endoleaks transmit pulsatile pressure of near systemic level and indicate insufficient treatment result. In contrast, complete endovascular exclusion of aneurysms results in significantly reduced pressure exposure.« less
Linear MALDI-ToF simultaneous spectrum deconvolution and baseline removal.
Picaud, Vincent; Giovannelli, Jean-Francois; Truntzer, Caroline; Charrier, Jean-Philippe; Giremus, Audrey; Grangeat, Pierre; Mercier, Catherine
2018-04-05
Thanks to a reasonable cost and simple sample preparation procedure, linear MALDI-ToF spectrometry is a growing technology for clinical microbiology. With appropriate spectrum databases, this technology can be used for early identification of pathogens in body fluids. However, due to the low resolution of linear MALDI-ToF instruments, robust and accurate peak picking remains a challenging task. In this context we propose a new peak extraction algorithm from raw spectrum. With this method the spectrum baseline and spectrum peaks are processed jointly. The approach relies on an additive model constituted by a smooth baseline part plus a sparse peak list convolved with a known peak shape. The model is then fitted under a Gaussian noise model. The proposed method is well suited to process low resolution spectra with important baseline and unresolved peaks. We developed a new peak deconvolution procedure. The paper describes the method derivation and discusses some of its interpretations. The algorithm is then described in a pseudo-code form where the required optimization procedure is detailed. For synthetic data the method is compared to a more conventional approach. The new method reduces artifacts caused by the usual two-steps procedure, baseline removal then peak extraction. Finally some results on real linear MALDI-ToF spectra are provided. We introduced a new method for peak picking, where peak deconvolution and baseline computation are performed jointly. On simulated data we showed that this global approach performs better than a classical one where baseline and peaks are processed sequentially. A dedicated experiment has been conducted on real spectra. In this study a collection of spectra of spiked proteins were acquired and then analyzed. Better performances of the proposed method, in term of accuracy and reproductibility, have been observed and validated by an extended statistical analysis.
Hansen, Andrew H; Meier, Margrit R; Sessoms, Pinata H; Childress, Dudley S
2006-12-01
The Shape&Roll prosthetic foot was used to examine the effect of roll-over shape arc length on the gait of 14 unilateral trans-tibial prosthesis users. Simple modifications to the prosthetic foot were used to alter the effective forefoot rocker length, leaving factors such as alignment, limb length, and heel and mid-foot characteristics unchanged. Shortening the roll-over shape arc length caused a significant reduction in the maximum external dorsiflexion moment on the prosthetic side at all walking speeds (p < 0.001 for main effect of arc length), due to a reduction in forefoot leverage (moment arm) about the ankle. Roll-over shape arc length significantly affected the initial loading on the sound limb at normal and fast speeds (p = 0.001 for the main effect of arc length), with participants experiencing larger first peaks of vertical ground reaction forces on their sound limbs when using the foot with the shortest effective forefoot rocker arc length. Additionally, the difference between step lengths on the sound and prosthetic limbs was larger with the shortest arc length condition, although this difference was not statistically significant (p = 0.06 for main effect). It appears that prosthesis users may experience a drop-off effect at the end of single limb stance on prosthetic feet with short roll-over shape arc lengths, leading to increased loading and/or a shortened step on the contralateral limb.
Earthquakes Versus Surface Deformation: Qualitative and Quantitative Relationships From The Aegean
NASA Astrophysics Data System (ADS)
Pavlides, S.; Caputo, R.
Historical seismicity of the Aegean Region has been revised in order to associate major earthquakes to specific seismogenic structures. Only earthquakes associated to normal faulting have been considered. All available historical and seismotectonic data relative to co-seismic surface faulting have been collected in order to evaluate the surface rup- ture length (SRL) and the maximum displacement (MD). In order to perform Seismic Hazard analyses, empirical relationships between these parameters and the magnitude have been inferred and the best fitting regression functions have been calculated. Both co-seismic fault rupture lengths and maximum displacements show a logarithmic re- lationships, but our data from the Aegean Region have systematically lower values than the same parameters world-wide though they are similar to those of the East- ern Mediterranean-Middle East region. The upper envelopes of our diagrams (SRL vs Mw and MD vs Mw) have been also estimated and discussed, because they give useful information of the wort-case scenarios; these curces will be also discussed. Further- more, geological and morphological criteria have been used to recognise the tectonic structures along which historical earthquakes occurred in order to define the geolog- ical fault length (GFL). Accordingly, the SRL/GFL ratio seems to have a bimodal distribution with a major peak about 0.8-1.0, indicating that several earthquakes break through almost the entire geological fault length, and a second peak around 0.5, re- lated to the possible segmentation of these major neotectonic faults. In contrast, no relationships can be depicted between the SRL/GFL ratio and the magnitude of the corresponding events.
A novel peak detection approach with chemical noise removal using short-time FFT for prOTOF MS data.
Zhang, Shuqin; Wang, Honghui; Zhou, Xiaobo; Hoehn, Gerard T; DeGraba, Thomas J; Gonzales, Denise A; Suffredini, Anthony F; Ching, Wai-Ki; Ng, Michael K; Wong, Stephen T C
2009-08-01
Peak detection is a pivotal first step in biomarker discovery from MS data and can significantly influence the results of downstream data analysis steps. We developed a novel automatic peak detection method for prOTOF MS data, which does not require a priori knowledge of protein masses. Random noise is removed by an undecimated wavelet transform and chemical noise is attenuated by an adaptive short-time discrete Fourier transform. Isotopic peaks corresponding to a single protein are combined by extracting an envelope over them. Depending on the S/N, the desired peaks in each individual spectrum are detected and those with the highest intensity among their peak clusters are recorded. The common peaks among all the spectra are identified by choosing an appropriate cut-off threshold in the complete linkage hierarchical clustering. To remove the 1 Da shifting of the peaks, the peak corresponding to the same protein is determined as the detected peak with the largest number among its neighborhood. We validated this method using a data set of serial peptide and protein calibration standards. Compared with MoverZ program, our new method detects more peaks and significantly enhances S/N of the peak after the chemical noise removal. We then successfully applied this method to a data set from prOTOF MS spectra of albumin and albumin-bound proteins from serum samples of 59 patients with carotid artery disease compared to vascular disease-free patients to detect peaks with S/N> or =2. Our method is easily implemented and is highly effective to define peaks that will be used for disease classification or to highlight potential biomarkers.
Vergniolle, S.; Boichu, M.; Caplan-Auerbach, J.
2004-01-01
The 1999 basaltic eruption of Shishaldin volcano (Alaska, USA) displayed both classical Strombolian activity and an explosive Subplinian plume. Strombolian activity at Shishaldin occurred in two major phases following the Subplinian activity. In this paper, we use acoustic measurements to interpret the Strombolian activity. Acoustic measurements of the two Strombolian phases show a series of explosions that are modeled by the vibration of a large overpressurised cylindrical bubble at the top of the magma column. Results show that the bubble does not burst at its maximum radius, as expected if the liquid film is stretched beyond its elasticity. But bursting occurs after one cycle of vibration, as a consequence of an instability of the air-magma interface close to the bubble minimum radius. During each Strombolian period, estimates of bubble length and overpressure are calculated. Using an alternate method based on acoustic power, we estimate gas velocity to be 30-60 m/s, in very good agreement with synthetic waveforms. Although there is some variation within these parameters, bubble length and overpressure for the first Strombolian phase are found to be ??? 82 ?? 11 m and 0.083 MPa. For the second Strombolian phase, bubble length and overpressure are estimated at 24 ?? 12 m and 0.15 MPa for the first 17 h after which bubble overpressure shows a constant increase, reaching a peak of 1.4 MPa, just prior to the end of the second Strombolian phase. This peak suggests that, at the time, the magma in the conduit may contain a relatively large concentration of small bubbles. Maximum total gas volume and gas fluxes at the surface are estimated to be 3.3 ?? 107 and 2.9 ?? 103 m3/s for the first phase and 1.0 ?? 108 and 2.2 ?? 103 m3/s for the second phase. This gives a mass flux of 1.2 ?? 103 and 8.7 ?? 102 kg/s, respectively, for the first and the second Strombolian phases. ?? 2004 Elsevier B.V. All rights reserved.
Picking ChIP-seq peak detectors for analyzing chromatin modification experiments
Micsinai, Mariann; Parisi, Fabio; Strino, Francesco; Asp, Patrik; Dynlacht, Brian D.; Kluger, Yuval
2012-01-01
Numerous algorithms have been developed to analyze ChIP-Seq data. However, the complexity of analyzing diverse patterns of ChIP-Seq signals, especially for epigenetic marks, still calls for the development of new algorithms and objective comparisons of existing methods. We developed Qeseq, an algorithm to detect regions of increased ChIP read density relative to background. Qeseq employs critical novel elements, such as iterative recalibration and neighbor joining of reads to identify enriched regions of any length. To objectively assess its performance relative to other 14 ChIP-Seq peak finders, we designed a novel protocol based on Validation Discriminant Analysis (VDA) to optimally select validation sites and generated two validation datasets, which are the most comprehensive to date for algorithmic benchmarking of key epigenetic marks. In addition, we systematically explored a total of 315 diverse parameter configurations from these algorithms and found that typically optimal parameters in one dataset do not generalize to other datasets. Nevertheless, default parameters show the most stable performance, suggesting that they should be used. This study also provides a reproducible and generalizable methodology for unbiased comparative analysis of high-throughput sequencing tools that can facilitate future algorithmic development. PMID:22307239
A novel route for synthesis of nanocrystalline hydroxyapatite from eggshell waste.
Siva Rama Krishna, D; Siddharthan, A; Seshadri, S K; Sampath Kumar, T S
2007-09-01
The eggshell waste has been value engineered to a nanocrystalline hydroxyapatite (HA) by microwave processing. To highlight the advantages of eggshell as calcium precursor in the synthesis of HA (OHA), synthetic calcium hydroxide was also used to form HA (SHA) following similar procedure and were compared with a commercially available pure HA (CHA). All the HAs were characterized by X-ray powder diffraction (XRD) method, Fourier transform infrared (FT-IR) spectroscopy, scanning electron microscopy (SEM), transmission electron microscopy (TEM) and specific surface area measurements. Nanocrystalline nature of OHA is revealed through characteristic broad peaks in XRD patterns, platelets of length 33-50 nm and width 8-14 nm in TEM micrograph and size calculations from specific surface area measurements. FT-IR spectra showed characteristic bands of HA and additionally peaks of carbonate ions. The cell parameter calculations suggest the formation of carbonated HA of B-type. The OHA exhibits superior sinterability in terms of hardness and density than both SHA and CHA may be due to larger surface area of its spherulite structure. The in vitro dissolution study shows longer stability in phosphate buffer and cell culture test using osteoblast cells establishes biocompatibility of OHA.
Picking ChIP-seq peak detectors for analyzing chromatin modification experiments.
Micsinai, Mariann; Parisi, Fabio; Strino, Francesco; Asp, Patrik; Dynlacht, Brian D; Kluger, Yuval
2012-05-01
Numerous algorithms have been developed to analyze ChIP-Seq data. However, the complexity of analyzing diverse patterns of ChIP-Seq signals, especially for epigenetic marks, still calls for the development of new algorithms and objective comparisons of existing methods. We developed Qeseq, an algorithm to detect regions of increased ChIP read density relative to background. Qeseq employs critical novel elements, such as iterative recalibration and neighbor joining of reads to identify enriched regions of any length. To objectively assess its performance relative to other 14 ChIP-Seq peak finders, we designed a novel protocol based on Validation Discriminant Analysis (VDA) to optimally select validation sites and generated two validation datasets, which are the most comprehensive to date for algorithmic benchmarking of key epigenetic marks. In addition, we systematically explored a total of 315 diverse parameter configurations from these algorithms and found that typically optimal parameters in one dataset do not generalize to other datasets. Nevertheless, default parameters show the most stable performance, suggesting that they should be used. This study also provides a reproducible and generalizable methodology for unbiased comparative analysis of high-throughput sequencing tools that can facilitate future algorithmic development.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-02
... hydraulic head of 1,465 feet; (2) a proposed 50-ft zoned earth and rockfill lower dam with a 5,896-ft length... 150 MW and two 50 MW reversible pump/turbine generating units having an installed capacity of 250...
Genetic control of flowering and biomass in switchgrass
USDA-ARS?s Scientific Manuscript database
Early flowering can negatively affect biomass yield of switchgrass. In temperate regions of the USA, flowering occurs in switchgrass around the time of peak biomass yield (about 5 to 8 weeks prior to killing frost), effectively reducing the length of the growing season. The use of late-flowering swi...
Providing Increased Transit Capacity During Peak Periods : Examination of Two Techniques
DOT National Transportation Integrated Search
1975-02-01
It is shown that reduction of bus route lengths increases the number of round trips per bus possible in a given time period. For bus routes accessed mainly by auto, it is shown that significant savings in energy due to reduced auto miles travelled ar...
Atmospheric Angular Momentum and Length of Day.
1988-03-01
seasonal terms. Of particular note is the difference in amplitudes found in mid July of 1984 and 1986. The Quasi- Biennual-Oscillation ( QBO ) peaked at...biannual bias which is probably associated with the QBO . Fig. 6 on page 24 contains the semiannual part of the seasonal signal. The spectral response of the
Telfer, Scott; Gibson, Kellie S; Hennessy, Kym; Steultjens, Martijn P; Woodburn, Jim
2012-05-01
To determine, for a number of techniques used to obtain foot shape based around plaster casting, foam box impressions, and 3-dimensional scanning, (1) the effect the technique has on the overall reproducibility of custom foot orthoses (FOs) in terms of inter- and intracaster reliability and (2) the reproducibility of FO design by using computer-aided design (CAD) software in terms of inter- and intra-CAD operator reliability for all these techniques. Cross-sectional study. University laboratory. Convenience sample of individuals (N=22) with noncavus foot types. Not applicable. Parameters of the FO design (length, width at forefoot, width at rearfoot, and peak medial arch height), the forefoot to rearfoot angle of the foot shape, and overall volume match between device designs. For intra- and intercaster reliability of the different methods of obtaining the foot shape, all methods fell below the reproducibility quality threshold for the medial arch height of the device, and volume matching was <80% for all methods. The more experienced CAD operator was able to achieve excellent reliability (intraclass correlation coefficients >0.75) for all variables with the exception of forefoot to rearfoot angle, with overall volume matches of >87% of the devices. None of the techniques for obtaining foot shape met all the criteria for excellent reproducibility, with the peak arch height being particularly variable. Additional variability is added at the CAD stage of the FO design process, although with adequate operator experience good to excellent reproducibility may be achieved at this stage. Taking only basic linear or angular measurement parameters from the device may fail to fully capture the variability in FO design. Copyright © 2012 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Hydroxyapatite synthesis using EDTA.
Kang, Nak Heon; Kim, Soon Je; Song, Seung Han; Choi, Sang mun; Choi, Sik Young; Kim, Youn Jung
2013-05-01
Bone comprises structure of the body and consisted of inorganic substances. It exists in an organic structure in the body. Even though it is firm and has self-healing mechanism, it can be damaged by trauma, cancer, or bone diseases. Allograft can be an alternative solution for autologous bone graft. Hydroxyapatite (Ca10(PO4)6(OH)2), an excellent candidate for allograft, can be applied to bone defect area. There are several methods to produce hydroxyapatite; however, economical cost and being time consuming make the production difficult. In this study, we synthesized hydroxyapatite with EDTA. Freeze-dried bone allograft (Hans Biomed) was used as the control group. Synthesized hydroxyapatite was a rod-shaped, white powdery substance with 2- to 5-μm length and 0.5- to 1-μm width. X-ray diffraction showed the highest sharp peak at 32°C and high peaks at 25.8°C, 39.8°C, 46.8°C, 49.5°C, and 64.0°C, indicating a similar substance to the freeze-dried bone allograft. After 3 days, the cell growth of synthesized hydroxyapatite showed 1.5-fold more than did the bone allograft. Cellular and media alkaline phosphate activity increased similar to the bone allograft. In this study, we came up with a new method to produce the hydroxyapatite. It is a convenient method that can be held in room temperature and low pressure. Also, the product can be manufactured in large quantity. It can be also transformed into scaffold structure, which will perform a stronger configuration. The manufacturing method will help the bony defect patients and make future medical products.
The Effect of Pulse Length and Ejector Radius on Unsteady Ejector Performance
NASA Technical Reports Server (NTRS)
Wilson, Jack
2005-01-01
The thrust augmentation of a set of ejectors driven by a shrouded Hartmann-Sprenger tube has been measured at four different frequencies. Each frequency corresponded to a different length to diameter ratio of the pulse of air leaving the driver shroud. Two of the frequencies had length to diameter ratios below the formation number, and two above. The formation number is the value of length to diameter ratio below which the pulse converts to a vortex ring only, and above which the pulse becomes a vortex ring plus a trailing jet. A three level, three parameter Box-Behnken statistical design of experiment scheme was performed at each frequency, measuring the thrust augmentation generated by the appropriate ejectors from the set. The three parameters were ejector length, radius, and inlet radius. The results showed that there is an optimum ejector radius and length at each frequency. Using a polynomial fit to the data, the results were interpolated to different ejector radii and pulse length to diameter ratios. This showed that a peak in thrust augmentation occurs when the pulse length to diameter ratio equals the formation number, and that the optimum ejector radius is 0.87 times the sum of the vortex ring radius and the core radius.
Miller, R M; Jastrow, J D; Reinhardt, D R
1995-07-01
External hyphae of vesicular-arbuscular mycorrhizal (VAM) fungi were quantified over a growing season in a reconstructed tallgrass prairie and an ungrazed cool-season pasture. In both sites, hyphal lengths increased throughout the growing season. Peak external hyphal lengths were 111 m cm -3 of soil in the prairie and 81 m cm -3 of soil in the pasture. These hyphal lengths calculate to external hyphal dry weights of 457 μg cm -3 and 339 μg cm -3 of soil for prairie and pasture communities, respectively. The relationships among external hyphal length, root characteristics, soil P and soil moisture were also determined. Measures of gross root morphology [e.g., specific root length (SRL) and root mass] have a strong association with external hyphal length. Over the course of the study, both grassland communities experienced a major drought event in late spring. During this period a reduction in SRL occurred in both the pasture and prairie without a measured reduction in external hyphal length. Recovery for both the pasture and prairie occurred not by increasing SRL, but rather by increasing external hyphal length. This study suggests that growth is coordinated between VAM hyphae and root morphology, which in turn, are constrained by plant community composition and soil nutrient and moisture conditions.
Assecondi, Sara; Bianchi, A M; Hallez, H; Staelens, S; Casarotto, S; Lemahieu, I; Chiarenza, G A
2009-10-01
This article proposes a method to automatically identify and label event-related potential (ERP) components with high accuracy and precision. We present a framework, referred to as peak-picking Dynamic Time Warping (ppDTW), where a priori knowledge about the ERPs under investigation is used to define a reference signal. We developed a combination of peak-picking and Dynamic Time Warping (DTW) that makes the temporal intervals for peak-picking adaptive on the basis of the morphology of the data. We tested the procedure on experimental data recorded from a control group and from children diagnosed with developmental dyslexia. We compared our results with the traditional peak-picking. We demonstrated that our method achieves better performance than peak-picking, with an overall precision, recall and F-score of 93%, 86% and 89%, respectively, versus 93%, 80% and 85% achieved by peak-picking. We showed that our hybrid method outperforms peak-picking, when dealing with data involving several peaks of interest. The proposed method can reliably identify and label ERP components in challenging event-related recordings, thus assisting the clinician in an objective assessment of amplitudes and latencies of peaks of clinical interest.
NASA Astrophysics Data System (ADS)
Perelló, José; Valencia, Víctor A.; Cornejo, Paula; Clifford, John; Wilson, Alan J.; Collins, Greg
2018-04-01
The Janice Lake Cu-Ag mineralization in the Wollaston Domain of northern Saskatchewan is hosted by a metasedimentary sequence in the upper part of the Wollaston Supergroup of the Trans-Hudson orogen. The Wollaston Supergroup was deposited between 2070 and 1865 Ma in a foreland basin setting constructed over Archean basement of the Hearne craton. The Trans-Hudson orogen underwent final collision and peak metamorphism at 1810 Ma, during consolidation of Laurentia and its amalgamation with the Columbia supercontinent. Titanite is a common constituent of the post-peak metamorphic assemblages of Trans-Hudson lithotectonic units and accompanied disseminated sediment-hosted Cu sulfide mineralization at Janice Lake. Titanite crystals, intergrown with chalcocite over a strike-length of 2 km of Cu-bearing stratigraphy, were dated by the ID-TIMS and LA-ICP-MS U-Pb methods, returning an age range from 1780 to 1760 Ma and a weighted average age of 1775 ± 10 Ma. The titanite ages effectively date the associated chalcocite-dominated sediment-hosted Cu-Ag mineralization and its formation during initial post-orogenic uplift and cooling, 30 myr after peak metamorphism. The age-range and tectonic setting of the Janice Lake mineralization confirms that sediment-hosted Cu mineralization was an integral part of the metallogenic endowment of Columbia and that its emplacement coincided with the continental-scale Trans-Hudson orogeny rather than with diagenesis and extensional basin development 100 myr earlier.
QRS peak detection for heart rate monitoring on Android smartphone
NASA Astrophysics Data System (ADS)
Pambudi Utomo, Trio; Nuryani, Nuryani; Darmanto
2017-11-01
In this study, Android smartphone is used for heart rate monitoring and displaying electrocardiogram (ECG) graph. Heart rate determination is based on QRS peak detection. Two methods are studied to detect the QRS complex peak; they are Peak Threshold and Peak Filter. The acquisition of ECG data is utilized by AD8232 module from Analog Devices, three electrodes, and Microcontroller Arduino UNO R3. To record the ECG data from a patient, three electrodes are attached to particular body’s surface of a patient. Patient’s heart activity which is recorded by AD8232 module is decoded by Arduino UNO R3 into analog data. Then, the analog data is converted into a voltage value (mV) and is processed to get the QRS complex peak. Heart rate value is calculated by Microcontroller Arduino UNO R3 uses the QRS complex peak. Voltage, heart rate, and the QRS complex peak are sent to Android smartphone by Bluetooth HC-05. ECG data is displayed as the graph by Android smartphone. To evaluate the performance of QRS complex peak detection method, three parameters are used; they are positive predictive, accuracy and sensitivity. Positive predictive, accuracy, and sensitivity of Peak Threshold method is 92.39%, 70.30%, 74.62% and for Peak Filter method are 98.38%, 82.47%, 83.61%, respectively.
NASA Astrophysics Data System (ADS)
Zhao, Changhao; Hou, Dong; Chung, Ching-Chang; Yu, Yingying; Liu, Wenfeng; Li, Shengtao; Jones, Jacob L.
2017-11-01
The local structural behavior of PbZr0.5Ti0.5O3 (PZT 50/50) ceramics during application of an electric field was investigated using pair distribution function (PDF) analysis. In situ synchrotron total scattering was conducted, and the PDFs were calculated from the Fourier transform of the total scattering data. The PDF refinement of the zero-field data suggests a local-structure model with [001] Ti-displacement and negligible Zr-displacement. The directional PDFs at different field amplitudes indicate the bond-length distribution of the nearest Pb-B (B = Zr/Ti) pair changes significantly with the field. The radial distribution functions (RDFs) of a model for polarization rotation were calculated. The calculated and the experimental RDFs are consistent. This result suggests the changes in Pb-B bond-length distribution could be dominantly caused by polarization rotation. Peak fitting of the experimental RDFs was also conducted. The peak position trends with increasing field are mostly in agreement with the calculation result of the polarization rotation model. The area ratio of the peaks in the experimental RDFs also changed with field amplitude, indicating that Zr atoms have a detectable displacement driven by the electric field. Our study provides an experimental observation of the behaviors of PZT 50/50 under field at a local scale which supports the polarization rotation mechanism.
Pulsed Nd:YAG laser welding of cardiac pacemaker batteries with reduced heat input
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fuerschbach, P.W.; Hinkley, D.A.
1997-03-01
The effects of Nd:YAG laser beam welding process parameters on the resulting heat input in 304L stainless steel cardiac pacemaker batteries have been studied. By careful selection of process parameters, the results can be used to reduce temperatures near glass-to-metal seals and assure hermeticity in laser beam welding of high reliability components. Three designed response surface experiments were used to compare welding performance with lenses of varying focal lengths. The measured peak temperatures at the glass-to-metal seals varied from 65 to 140 C (149 to 284 F) and depended strongly on the levels of the experimental factors. It was foundmore » that welds of equivalent size can be made with significantly reduced temperatures. The reduction in battery temperatures has been attributed to an increase in the melting efficiency. This increase is thought to be due primarily to increased travel speeds, which were facilitated by high peak powers and low pulse energies. For longer focal length lenses, weld fusion zone widths were found to be greater even without a corresponding increase in the size of the weld. It was also found that increases in laser beam irradiance either by higher peak powers or smaller spot sizes created deeper and larger welds. These gains were attributed to an increase in the laser energy transfer efficiency.« less
Diakaridia, Sanogo; Pan, Yue; Xu, Pengbai; Zhou, Dengwang; Wang, Benzhang; Teng, Lei; Lu, Zhiwei; Ba, Dexin; Dong, Yongkang
2017-07-24
In distributed Brillouin optical fiber sensor when the length of the perturbation to be detected is much smaller than the spatial resolution that is defined by the pulse width, the measured Brillouin gain spectrum (BGS) experiences two or multiple peaks. In this work, we propose and demonstrate a technique using differential pulse pair Brillouin optical time-domain analysis (DPP-BOTDA) based on double-peak BGS to enhance small-scale events detection capability, where two types of single mode fiber (main fiber and secondary fiber) with 116 MHz Brillouin frequency shift (BFS) difference have been used. We have realized detection of a 5-cm hot spot at the far end of 24-km single mode fiber by employing a 50-cm spatial resolution DPP-BOTDA with only 1GS/s sampling rate (corresponding to 10 cm/point). The BFS at the far end of 24-km sensing fiber has been measured with 0.54 MHz standard deviation which corresponds to a 0.5°C temperature accuracy. This technique is simple and cost effective because it is implemented using the similar experimental setup of the standard BOTDA, however, it should be noted that the consecutive small-scale events have to be separated by a minimum length corresponding to the spatial resolution defined by the pulse width difference.
Focused ultrasound transducer spatial peak intensity estimation: a comparison of methods
NASA Astrophysics Data System (ADS)
Civale, John; Rivens, Ian; Shaw, Adam; ter Haar, Gail
2018-03-01
Characterisation of the spatial peak intensity at the focus of high intensity focused ultrasound transducers is difficult because of the risk of damage to hydrophone sensors at the high focal pressures generated. Hill et al (1994 Ultrasound Med. Biol. 20 259-69) provided a simple equation for estimating spatial-peak intensity for solid spherical bowl transducers using measured acoustic power and focal beamwidth. This paper demonstrates theoretically and experimentally that this expression is only strictly valid for spherical bowl transducers without a central (imaging) aperture. A hole in the centre of the transducer results in over-estimation of the peak intensity. Improved strategies for determining focal peak intensity from a measurement of total acoustic power are proposed. Four methods are compared: (i) a solid spherical bowl approximation (after Hill et al 1994 Ultrasound Med. Biol. 20 259-69), (ii) a numerical method derived from theory, (iii) a method using measured sidelobe to focal peak pressure ratio, and (iv) a method for measuring the focal power fraction (FPF) experimentally. Spatial-peak intensities were estimated for 8 transducers at three drive powers levels: low (approximately 1 W), moderate (~10 W) and high (20-70 W). The calculated intensities were compared with those derived from focal peak pressure measurements made using a calibrated hydrophone. The FPF measurement method was found to provide focal peak intensity estimates that agreed most closely (within 15%) with the hydrophone measurements, followed by the pressure ratio method (within 20%). The numerical method was found to consistently over-estimate focal peak intensity (+40% on average), however, for transducers with a central hole it was more accurate than using the solid bowl assumption (+70% over-estimation). In conclusion, the ability to make use of an automated beam plotting system, and a hydrophone with good spatial resolution, greatly facilitates characterisation of the FPF, and consequently gives improved confidence in estimating spatial peak intensity from measurement of acoustic power.
Aras, Aynur; Ada, Emel; Saracoğlu, Hatice; Gezer, Naciye S; Aras, Isil
2011-11-01
The aim of this study was to compare the dentoskeletal changes and alterations of mandibular condyle-disc-fossa relationships in subjects at the peak and the end of the pubertal growth period treated with the Forsus fatigue resistant device (3M Unitek, Monrovia, Calif). The sample consisted of 29 subjects with Class II Division 1 malocclusions who were classified according to their hand-wrist radiographs. Fifteen patients were at or just before the peak phase of pubertal growth (peak pubertal group). Fourteen patients were near the end of the pubertal growth period (late pubertal group). The study was conducted by using lateral cephalometric radiographs and magnetic resonance images obtained at the beginning and at the end of the application of the Forsus fatigue resistant device. The treatment period was 9 months. The Wilcoxon signed rank test was used to evaluate differences within groups. The changes observed in both groups were compared by using the Mann-Whitney U test. There were statistically significant group differences in mandibular length and ramus length, with significant increases of these parameters in the peak pubertal group (P <0.05). No significant differences were observed between the groups concerning dental parameters (P >0.05), with the exception of mandibular molar vertical movements, which were significantly greater in the peak pubertal group (P <0.05). Analysis of the magnetic resonance images showed no positional changes of the mandibular condyle in relation to the glenoid fossa in either group (P >0.05). Although the articular disc was positioned more anteriorly in the peak pubertal group compared with its pretreatment position (P <0.05), the position of the disc was still within the physiologic range. No significant intergroup difference was observed for disc-condyle relationship (P >0.05). The Forsus fatigue resistant device did not appear to cause significant increases in mandibular dimensions in subjects in late puberty. According to the magnetic resonance image findings, Forsus treatment is not a risk factor for the development of temporomandibular dysfunction in subjects with no signs and clinical symptoms of dysfunction. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
Fu, Hai-Yan; Guo, Jun-Wei; Yu, Yong-Jie; Li, He-Dong; Cui, Hua-Peng; Liu, Ping-Ping; Wang, Bing; Wang, Sheng; Lu, Peng
2016-06-24
Peak detection is a critical step in chromatographic data analysis. In the present work, we developed a multi-scale Gaussian smoothing-based strategy for accurate peak extraction. The strategy consisted of three stages: background drift correction, peak detection, and peak filtration. Background drift correction was implemented using a moving window strategy. The new peak detection method is a variant of the system used by the well-known MassSpecWavelet, i.e., chromatographic peaks are found at local maximum values under various smoothing window scales. Therefore, peaks can be detected through the ridge lines of maximum values under these window scales, and signals that are monotonously increased/decreased around the peak position could be treated as part of the peak. Instrumental noise was estimated after peak elimination, and a peak filtration strategy was performed to remove peaks with signal-to-noise ratios smaller than 3. The performance of our method was evaluated using two complex datasets. These datasets include essential oil samples for quality control obtained from gas chromatography and tobacco plant samples for metabolic profiling analysis obtained from gas chromatography coupled with mass spectrometry. Results confirmed the reasonability of the developed method. Copyright © 2016 Elsevier B.V. All rights reserved.
Liu, Bao; Fan, Xiaoming; Huo, Shengnan; Zhou, Lili; Wang, Jun; Zhang, Hui; Hu, Mei; Zhu, Jianhua
2011-12-01
A method was established to analyse the overlapped chromatographic peaks based on the chromatographic-spectra data detected by the diode-array ultraviolet detector. In the method, the three-dimensional data were de-noised and normalized firstly; secondly the differences and clustering analysis of the spectra at different time points were calculated; then the purity of the whole chromatographic peak were analysed and the region were sought out in which the spectra of different time points were stable. The feature spectra were extracted from the spectrum-stable region as the basic foundation. The nonnegative least-square method was chosen to separate the overlapped peaks and get the flow curve which was based on the feature spectrum. The three-dimensional divided chromatographic-spectrum peak could be gained by the matrix operations of the feature spectra with the flow curve. The results displayed that this method could separate the overlapped peaks.
Lewis, Mary E; Gowland, Rebecca
2007-09-01
This study compares the infant mortality profiles of 128 infants from two urban and two rural cemetery sites in medieval England. The aim of this paper is to assess the impact of urbanization and industrialization in terms of endogenous or exogenous causes of death. In order to undertake this analysis, two different methods of estimating gestational age from long bone lengths were used: a traditional regression method and a Bayesian method. The regression method tended to produce more marked peaks at 38 weeks, while the Bayesian method produced a broader range of ages and were more comparable with the expected "natural" mortality profiles.At all the sites, neonatal mortality (28-40 weeks) outweighed post-neonatal mortality (41-48 weeks) with rural Raunds Furnells in Northamptonshire, showing the highest number of neonatal deaths and post-medieval Spitalfields, London, showing a greater proportion of deaths due to exogenous or environmental factors. Of the four sites under study, Wharram Percy in Yorkshire showed the most convincing "natural" infant mortality profile, suggesting the inclusion of all births at the site (i.e., stillbirths and unbaptised infants). (c) 2007 Wiley-Liss, Inc.
Do the peak and mean force methods of assessing vertical jump force asymmetry agree?
Lake, Jason P; Mundy, Peter D; Comfort, Paul; Suchomel, Timothy J
2018-05-21
The aim of this study was to assess agreement between peak and mean force methods of quantifying force asymmetry during the countermovement jump (CMJ). Forty-five men performed four CMJ with each foot on one of two force plates recording at 1,000 Hz. Peak and mean were obtained from both sides during the braking and propulsion phases. The dominant side was obtained for the braking and propulsion phase as the side with the largest peak or mean force and agreement was assessed using percentage agreement and the kappa coefficient. Braking phase peak and mean force methods demonstrated a percentage agreement of 84% and a kappa value of 0.67 (95% confidence limits: 0.45-0.90), indicating substantial agreement. Propulsion phase peak and mean force methods demonstrated a percentage agreement of 87% and a kappa value of 0.72 (95% confidence limits: 0.51-0.93), indicating substantial agreement. While agreement was substantial, side-to-side differences were not reflected equally when peak and mean force methods of assessing CMJ asymmetry were used. These methods should not be used interchangeably, but rather a combined approach should be used where practitioners consider both peak and mean force to obtain the fullest picture of athlete asymmetry.
Kronberg, James W.
1990-08-07
A device for bending and trimming the pins of a dual-inline-package component and the like for surface mounting rather than through mounting to a circuit board comprises, in a first part, in pin cutter astride a holder having a recess for holding the component, a first spring therebetween, and, in a second part, two flat members pivotally interconnected by a hinge and urged to an upward peaked position from a downward peaked position by a second spring. As a downward force is applied to the pin cutter it urges the holder downward, assisted by the first spring and a pair of ridges riding on shoulders of the holder, to carry the component against the upward peaked flat members which guide the pins outwardly. As the holder continues downwardly, the flat members pivot to the downward peaked position bending the pins upwardly against the sides of the holder. When the downward movement is met with sufficient resistance, the ridges of the pin cutter ride over the holder's shoulders to continue downward to cut any excess length of pin.
FEM design and simulation of a short, 10 MV, S-band Linac with Monte Carlo dose simulations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baillie, Devin; Aubin, J. St.; Steciw, S., E-mail: ssteciw@ualberta.ca
2015-04-15
Purpose: Current commercial 10 MV Linac waveguides are 1.5 m. The authors’ current 6 MV linear accelerator–magnetic resonance imager (Linac–MR) system fits in typical radiotherapy vaults. To allow 10 MV treatments with the Linac–MR and still fit within typical vaults, the authors design a 10 MV Linac with an accelerator waveguide of the same length (27.5 cm) as current 6 MV Linacs. Methods: The first design stage is to design a cavity such that a specific experimental measurement for breakdown is applicable to the cavity. This is accomplished through the use of finite element method (FEM) simulations to match publishedmore » shunt impedance, Q factor, and ratio of peak to mean-axial electric field strength from an electric breakdown study. A full waveguide is then designed and tuned in FEM simulations based on this cavity design. Electron trajectories are computed through the resulting radio frequency fields, and the waveguide geometry is modified by shifting the first coupling cavity in order to optimize the electron beam properties until the energy spread and mean energy closely match values published for an emulated 10 MV Linac. Finally, Monte Carlo dose simulations are used to compare the resulting photon beam depth dose profile and penumbra with that produced by the emulated 10 MV Linac. Results: The shunt impedance, Q factor, and ratio of peak to mean-axial electric field strength are all matched to within 0.1%. A first coupling cavity shift of 1.45 mm produces an energy spectrum width of 0.347 MeV, very close to the published value for the emulated 10 MV of 0.315 MeV, and a mean energy of 10.53 MeV, nearly identical to the published 10.5 MeV for the emulated 10 MV Linac. The depth dose profile produced by their new Linac is within 1% of that produced by the emulated 10 MV spectrum for all depths greater than 1.5 cm. The penumbra produced is 11% narrower, as measured from 80% to 20% of the central axis dose. Conclusions: The authors have successfully designed and simulated an S-band waveguide of length of 27.5 cm capable of producing a 10 MV photon beam. This waveguide operates well within the breakdown threshold determined for the cavity geometry used. The designed Linac produces depth dose profiles similar to those of the emulated 10 MV Linac (waveguide-length of 1.5 m) but yields a narrower penumbra.« less
Gas chromatographic separation of fatty acid methyl esters on weakly polar capillary columns.
Yamamoto, Kouhei; Kinoshita, Akemi; Shibahara, Akira
2008-02-22
It was found that weakly polar columns, routinely used in capillary GC for analyzing sterols, food additives, etc., can also be used for separating fatty acid methyl esters (FAMEs). On these columns, FAMEs elute in the order of their unsaturation. The equivalent chain-length value of methyl 22:6 is below 23.00. This means FAMEs within a carbon chain length, having up to six double bonds, elute before the next (one carbon longer) saturated FAME elutes. Peak identification is easy. Weakly polar columns are compatible in both GC and GC/MS systems.
Tunable multimode-interference bandpass fiber filter.
Antonio-Lopez, J E; Castillo-Guzman, A; May-Arrioja, D A; Selvas-Aguilar, R; Likamwa, P
2010-02-01
We report on a wavelength-tunable filter based on multimode interference (MMI) effects. A typical MMI filter consists of a multimode fiber (MMF) spliced between two single-mode fibers (SMF). The peak wavelength response of the filter exhibits a linear dependence when the length of the MMF is modified. Therefore a capillary tube filled with refractive-index-matching liquid is used to effectively increase the length of the MMF, and thus wavelength tuning is achieved. Using this filter a ring-based tunable erbium-doped fiber laser is demonstrated with a tunability of 30 nm, covering the full C-band.
Investigation of Perforated Convergent-divergent Diffusers with Initial Boundary Layer
NASA Technical Reports Server (NTRS)
Weinstein, Maynard I
1950-01-01
An experimental investigation was made at Mach number 1.90 of the performance of a series of perforated convergent-divergent supersonic diffusers operating with initial boundary layer, which was induced and controlled by lengths of cylindrical inlets affixed to the diffusers. Supercritical mass-flow and peak total-pressure recoveries were decreased slightly by use of the longest inlets (4 inlet diameters in length). Combinations of cylindrical inlets, perforated diffusers, and subsonic diffuser were evaluated as simulated wind tunnels having second throats. Comparisons with noncontracted configurations of similar scale indicated conservatively computed power reductions of 25 percent.
Compression member response of double steel angles on truss structure with member length variation
NASA Astrophysics Data System (ADS)
Hasibuan, Purwandy; Panjaitan, Arief; Haiqal, Muhammad
2018-05-01
One type of structures that implements steel angles as its members is truss system of telecommunication tower. For this structure, reinforcements on tower legs are also needed when antennas and microwaves installation placed on the peak of tower increases in quantity. One type of reinforcement methods commonly used is by increasing areas section capacity, where tower leg consisted of single angle section will be reinforced to be double angle sections. Regarding this case, this research discussed behavior two types of double angle steel section 2L 30.30.3 that were designed identically in area section but vary in length: 103 cm and 83 cm. At the first step, compression member together with tension member was formed to be a truss system, where compression and tension member were met at the joint plate. Schematic loading was implemented by giving tension loading on the joint plate, and this loading was terminated when each specimen reached its failure. Research findings showed that implementing shorter double angle (83 cm) sections, increased compression strength of steel angle section up to 13 %. Significant deformation occurring only on the flange for both of specimens indicated that implementing double angle is effective to prevent lateral-torsional buckling.
Sandbakk, Øyvind; Leirdal, Stig; Ettema, Gertjan
2015-03-01
The current study compared differences in cycle characteristics, energy expenditure and peak speed between double poling (DP) and G3 skating. Eight world class male sprint skiers performed a 5-min submaximal test at 16 km h(-1) and an incremental test to exhaustion at a 5% incline during treadmill roller skiing with two different techniques: DP where all propulsion comes from poling, and G3 skating where leg skating is added to each double poling movement. Video analyses determined cycle characteristics; respiratory parameters and blood lactate concentration determined the physiological responses. G3 skating resulted in 16% longer cycle lengths at 16% lower cycle rates, whereas oxygen uptake was independent of technique during submaximal roller skiing. The corresponding advantages for G3 skating during maximal roller skiing were reflected in 14% higher speed, 30% longer cycle length at 16% lower cycle rate and 11% higher peak oxygen uptake (all p < 0.05). Compared to DP approximately 14% higher speed was achieved when leg push-offs were added in G3 skating. This was done by major increases in cycle lengths at slightly lower cycle rates and a higher aerobic energy delivery. However, the oxygen uptake for a given submaximal speed was not affected by technique although higher cycle rate was used in DP.
Characterization and manipulation of reproductive cycles in the jaguar (Panthera onca).
Barnes, Serena A; Andrew Teare, J; Staaden, Sheryl; Metrione, Lara; Penfold, Linda M
2016-01-01
Basic reproductive information in female jaguars (Panthera onca) is lacking, thus longitudinal fecal samples from seven females were analyzed via enzyme immunoassay to measure estradiol and progestin metabolites throughout the year. Mean estrus length of 194 estrus periods measured hormonally was 6.5±0.3d, mean peak fecal estradiol concentration was 138.7±5.7ng/g; and in one female, estrus resumption occurred approximately 15d post-partum. Ovulation, as indicted by sustained elevated progestin concentrations (>20d), was successfully induced one time by treatment with exogenous hormones in one female and by physical vaginal stimulation in two females a combined total of three times. Elevated fecal progestin was observed outside exogenous stimulation on five occasions, suggesting ovulation occurred spontaneously. Mean length of physically induced and spontaneous pseudopregnancies was 24.7±4.2d and 29.6±2.6d, respectively, and mean length of pregnancy (n=2) was 98.0±0.0d. Mean peak progestin concentration for spontaneous and induced pseudopregnancies, and pregnancy was 7.4±1.4μg/g, 6.4±1.2μg/g, and 13.7±1.0μg/g, respectively. This data suggests jaguars are polyestrous and generally induced ovulators, with a moderate incidence of spontaneous ovulation. Additionally, two protocols to successfully stimulate ovarian activity in jaguars are described. Copyright © 2015 Elsevier Inc. All rights reserved.
Comparative Dispositions of Ofloxacin in Human Head, Axillary, and Pubic Hairs
Kosuge, Kazuhiro; Uematsu, Toshihiko; Araki, Sei-Ichi; Matsuno, Hiroyuki; Ohashi, Kyoichi; Nakashima, Mitsuyoshi
1998-01-01
The distribution of ofloxacin (OFLX) along the shaft of each of three hair types, i.e., head, axillary and pubic, was investigated and compared among five healthy male volunteers 1 to 4 months after ingestion of OFLX for 1 or 2 days (total dose, 200 or 600 mg). Five strands of each hair type were sectioned together into successive 0.5-cm lengths starting from the dermal end, over a length of ≤6 cm, and the OFLX concentration in each hair section was measured by high-pressure liquid chromatography with fluorescence detection. The distribution of OFLX along the head hair shaft was narrow, having a single peak even 3 to 4 months after administration, suggesting a rather uniform growth rate among hair strands. On the other hand, the OFLX distribution along axillary or pubic hair shafts tended to be broad, even having two apparent peaks, and the growth rate did not seem uniform. Since axillary hair seemed to stop growing after having gained a length of ≤4 to 5 cm, it was suggested to enter a resting stage after the growth of ≤3 cm over the 2 to 4 months after OFLX incorporation. These findings indicate that head hair is the most suitable for analysis of individual drug use and the larger growth rate and cycle stage variabilities of strands of the other types of hair should be taken into account. PMID:9593174
Comparative dispositions of ofloxacin in human head, axillary, and pubic hairs.
Kosuge, K; Uematsu, T; Araki, S I; Matsuno, H; Ohashi, K; Nakashima, M
1998-05-01
The distribution of ofloxacin (OFLX) along the shaft of each of three hair types, i.e., head, axillary and pubic, was investigated and compared among five healthy male volunteers 1 to 4 months after ingestion of OFLX for 1 or 2 days (total dose, 200 or 600 mg). Five strands of each hair type were sectioned together into successive 0.5-cm lengths starting from the dermal end, over a length of < or = 6 cm, and the OFLX concentration in each hair section was measured by high-pressure liquid chromatography with fluorescence detection. The distribution of OFLX along the head hair shaft was narrow, having a single peak even 3 to 4 months after administration, suggesting a rather uniform growth rate among hair strands. On the other hand, the OFLX distribution along axillary or pubic hair shafts tended to be broad, even having two apparent peaks, and the growth rate did not seem uniform. Since axillary hair seemed to stop growing after having gained a length of < or = 4 to 5 cm, it was suggested to enter a resting stage after the growth of < or = 3 cm over the 2 to 4 months after OFLX incorporation. These findings indicate that head hair is the most suitable for analysis of individual drug use and the larger growth rate and cycle stage variabilities of strands of the other types of hair should be taken into account.
Autocorrelation peaks in congruential pseudorandom number generators
NASA Technical Reports Server (NTRS)
Neuman, F.; Merrick, R. B.
1976-01-01
The complete correlation structure of several congruential pseudorandom number generators (PRNG) of the same type and small cycle length was studied to deal with the problem of congruential PRNG almost repeating themselves at intervals smaller than their cycle lengths, during simulation of bandpass filtered normal random noise. Maximum period multiplicative and mixed congruential generators were studied, with inferences drawn from examination of several tractable members of a class of random number generators, and moduli from 2 to the 5th power to 2 to the 9th power. High correlation is shown to exist in mixed and multiplicative congruential random number generators and prime moduli Lehmer generators for shifts a fraction of their cycle length. The random noise sequences in question are required when simulating electrical noise, air turbulence, or time variation of wind parameters.
Fidler, Justyna; Zdunek-Zastocka, Edyta; Prabucka, Beata; Bielawski, Wiesław
2016-12-01
Abscisic acid (ABA) is a plant hormone that plays a predominant role in the onset and maintenance of primary dormancy. Peak ABA accumulation in embryos of triticale grains was observed before any significant loss of water and was higher in Fredro, a cultivar less susceptible to pre-harvest sprouting (PHS), than in Leontino, a cultivar more sensitive to PHS. At full maturity, embryonic ABA content in Fredro was twice as high as in Leontino. Two full-length cDNAs of 9-cis-epoxycarotenoid dioxygenase (TsNCED1, TsNCED2), an enzyme involved in ABA biosynthesis, and two full-length cDNAs of ABA 8'-hydroxylase (TsABA8'OH1 and TsABA8'OH2), an enzyme involved in ABA catabolism, were identified in triticale grains and characterized. The maximum transcript level of both TsNCED1 and TsNCED2 preceded the peak of ABA accumulation, suggesting that both TsNCEDs contribute to reach this peak, although the expression of TsNCED1 was significantly higher in Fredro than in Leontino. High expression of TsABA8'OH2 and TsABA8'OH1 was observed long before and at the end of the ABA accumulation peak, respectively, but no differences were observed between cultivars. The obtained results suggest that mainly TsNCED1 might be related to the higher ABA content and higher resistance of Fredro to PHS. However, Fredro embryos not only have higher ABA content, but also exhibit greater sensitivity to ABA, which may also have a significant effect on grain dormancy and lower susceptibility to PHS for grains of this cultivar. Copyright © 2016 Elsevier GmbH. All rights reserved.
Krug, Johannes W; Rose, Georg; Clifford, Gari D; Oster, Julien
2013-11-19
In Cardiovascular Magnetic Resonance (CMR), the synchronization of image acquisition with heart motion is performed in clinical practice by processing the electrocardiogram (ECG). The ECG-based synchronization is well established for MR scanners with magnetic fields up to 3 T. However, this technique is prone to errors in ultra high field environments, e.g. in 7 T MR scanners as used in research applications. The high magnetic fields cause severe magnetohydrodynamic (MHD) effects which disturb the ECG signal. Image synchronization is thus less reliable and yields artefacts in CMR images. A strategy based on Independent Component Analysis (ICA) was pursued in this work to enhance the ECG contribution and attenuate the MHD effect. ICA was applied to 12-lead ECG signals recorded inside a 7 T MR scanner. An automatic source identification procedure was proposed to identify an independent component (IC) dominated by the ECG signal. The identified IC was then used for detecting the R-peaks. The presented ICA-based method was compared to other R-peak detection methods using 1) the raw ECG signal, 2) the raw vectorcardiogram (VCG), 3) the state-of-the-art gating technique based on the VCG, 4) an updated version of the VCG-based approach and 5) the ICA of the VCG. ECG signals from eight volunteers were recorded inside the MR scanner. Recordings with an overall length of 87 min accounting for 5457 QRS complexes were available for the analysis. The records were divided into a training and a test dataset. In terms of R-peak detection within the test dataset, the proposed ICA-based algorithm achieved a detection performance with an average sensitivity (Se) of 99.2%, a positive predictive value (+P) of 99.1%, with an average trigger delay and jitter of 5.8 ms and 5.0 ms, respectively. Long term stability of the demixing matrix was shown based on two measurements of the same subject, each being separated by one year, whereas an averaged detection performance of Se = 99.4% and +P = 99.7% was achieved.Compared to the state-of-the-art VCG-based gating technique at 7 T, the proposed method increased the sensitivity and positive predictive value within the test dataset by 27.1% and 42.7%, respectively. The presented ICA-based method allows the estimation and identification of an IC dominated by the ECG signal. R-peak detection based on this IC outperforms the state-of-the-art VCG-based technique in a 7 T MR scanner environment.
Estimating the Magnitude and Frequency of Floods in Small Urban Streams in South Carolina, 2001
Feaster, Toby D.; Guimaraes, Wladimir B.
2004-01-01
The magnitude and frequency of floods at 20 streamflowgaging stations on small, unregulated urban streams in or near South Carolina were estimated by fitting the measured wateryear peak flows to a log-Pearson Type-III distribution. The period of record (through September 30, 2001) for the measured water-year peak flows ranged from 11 to 25 years with a mean and median length of 16 years. The drainage areas of the streamflow-gaging stations ranged from 0.18 to 41 square miles. Based on the flood-frequency estimates from the 20 streamflow-gaging stations (13 in South Carolina; 4 in North Carolina; and 3 in Georgia), generalized least-squares regression was used to develop regional regression equations. These equations can be used to estimate the 2-, 5-, 10-, 25-, 50-, 100-, 200-, and 500-year recurrence-interval flows for small urban streams in the Piedmont, upper Coastal Plain, and lower Coastal Plain physiographic provinces of South Carolina. The most significant explanatory variables from this analysis were mainchannel length, percent impervious area, and basin development factor. Mean standard errors of prediction for the regression equations ranged from -25 to 33 percent for the 10-year recurrence-interval flows and from -35 to 54 percent for the 100-year recurrence-interval flows. The U.S. Geological Survey has developed a Geographic Information System application called StreamStats that makes the process of computing streamflow statistics at ungaged sites faster and more consistent than manual methods. This application was developed in the Massachusetts District and ongoing work is being done in other districts to develop a similar application using streamflow statistics relative to those respective States. Considering the future possibility of implementing StreamStats in South Carolina, an alternative set of regional regression equations was developed using only main channel length and impervious area. This was done because no digital coverages are currently available for basin development factor and, therefore, it could not be included in the StreamStats application. The average mean standard error of prediction for the alternative equations was 2 to 5 percent larger than the standard errors for the equations that contained basin development factor. For the urban streamflow-gaging stations in South Carolina, measured water-year peak flows were compared with those from an earlier urban flood-frequency investigation. The peak flows from the earlier investigation were computed using a rainfall-runoff model. At many of the sites, graphical comparisons indicated that the variance of the measured data was much less than the variance of the simulated data. Several statistical tests were applied to compare the variances and the means of the measured and simulated data for each site. The results indicated that the variances were significantly different for 11 of the 13 South Carolina streamflow-gaging stations. For one streamflow-gaging station, the test for normality, which is one of the assumptions of the data when comparing variances, indicated that neither the measured data nor the simulated data were distributed normally; therefore, the test for differences in the variances was not used for that streamflow-gaging station. Another statistical test was used to test for statistically significant differences in the means of the measured and simulated data. The results indicated that for 5 of the 13 urban streamflowgaging stations in South Carolina there was a statistically significant difference in the means of the two data sets. For comparison purposes and to test the hypothesis that there may have been climatic differences between the period in which the measured peak-flow data were measured and the period for which historic rainfall data were used to compute the simulated peak flows, 16 rural streamflow-gaging stations with long-term records were reviewed using similar techniques as those used for the measured an
NASA Astrophysics Data System (ADS)
Bisdom, Kevin; Bertotti, Giovanni; Nick, Hamidreza M.
2016-05-01
Predicting equivalent permeability in fractured reservoirs requires an understanding of the fracture network geometry and apertures. There are different methods for defining aperture, based on outcrop observations (power law scaling), fundamental mechanics (sublinear length-aperture scaling), and experiments (Barton-Bandis conductive shearing). Each method predicts heterogeneous apertures, even along single fractures (i.e., intrafracture variations), but most fractured reservoir models imply constant apertures for single fractures. We compare the relative differences in aperture and permeability predicted by three aperture methods, where permeability is modeled in explicit fracture networks with coupled fracture-matrix flow. Aperture varies along single fractures, and geomechanical relations are used to identify which fractures are critically stressed. The aperture models are applied to real-world large-scale fracture networks. (Sub)linear length scaling predicts the largest average aperture and equivalent permeability. Barton-Bandis aperture is smaller, predicting on average a sixfold increase compared to matrix permeability. Application of critical stress criteria results in a decrease in the fraction of open fractures. For the applied stress conditions, Coulomb predicts that 50% of the network is critically stressed, compared to 80% for Barton-Bandis peak shear. The impact of the fracture network on equivalent permeability depends on the matrix hydraulic properties, as in a low-permeable matrix, intrafracture connectivity, i.e., the opening along a single fracture, controls equivalent permeability, whereas for a more permeable matrix, absolute apertures have a larger impact. Quantification of fracture flow regimes using only the ratio of fracture versus matrix permeability is insufficient, as these regimes also depend on aperture variations within fractures.
STREAMFLOW LOSSES IN THE SANTA CRUZ RIVER, ARIZONA.
Aldridge, B.N.
1985-01-01
The discharge and volume of flow in a peak decrease as the peak moves through an 89-mile (143 km) reach of the Santa Cruz River. An average of three peaks per year flow the length of the reach. Of 17,500 acre-ft (21,600 dam**3) that entered the upstream end of the reach, 2300 acre-ft (2,840 dam**3), 13 percent of the inflow, left the reach as streamflow. The remainder was lost through infiltration. Losses in a reach of channel were estimated by relating losses to the discharge at the upstream end of the reach. Tributary inflow was estimated through the use of synthesized duration curves. Streamflow losses along mountain fronts were estimated through the use of an electric analog model and by relating losses shown by the model to the median altitude of the contributing area.
Numerical analysis of the slipstream development around a high-speed train in a double-track tunnel.
Fu, Min; Li, Peng; Liang, Xi-Feng
2017-01-01
Analysis of the slipstream development around the high-speed trains in tunnels would provide references for assessing the transient gust loads on trackside workers and trackside furniture in tunnels. This paper focuses on the computational analysis of the slipstream caused by high-speed trains passing through double-track tunnels with a cross-sectional area of 100 m2. Three-dimensional unsteady compressible Reynolds-averaged Navier-Stokes equations and a realizable k-ε turbulence model were used to describe the airflow characteristics around a high-speed train in the tunnel. The moving boundary problem was treated using the sliding mesh technology. Three cases were simulated in this paper, including two tunnel lengths and two different configurations of the train. The train speed in these three cases was 250 km/h. The accuracy of the numerical method was validated by the experimental data from full-scale tests, and reasonable consistency was obtained. The results show that the flow field around the high-speed trains can be divided into three distinct regions: the region in front of the train nose, the annular region and the wake region. The slipstream development along the two sides of train is not in balance and offsets to the narrow side in the double-track tunnels. Due to the piston effect, the slipstream has a larger peak value in the tunnel than in open air. The tunnel length, train length and length ratio affect the slipstream velocities; in particular, the velocities increase with longer trains. Moreover, the propagation of pressure waves also induces the slipstream fluctuations: substantial velocity fluctuations mainly occur in front of the train, and weaken with the decrease in amplitude of the pressure wave.
Sun, S; Huang, X; Zhang, L; Ren, P; Chang, Z
2001-10-01
To improve the HPLC method for determining ferulic acid(FA) in the human serum and to research FA clinical pharmacokinetics. Serum concentrations of FA were determined by HPLC using methanol-water-acetic acid (40:59.7:0.3, v/v) as the mobile phase and the column packed with ODS (150 mm x 4.6 mm, 5 microns) as a fixed phase and the flow rate was 1.0 ml/min. FA was detected at 320 nm wave length. The internal standard was coumarin. The serum samples were treated by the water-boiling method. Peak of FA in serum was recognized by photodiode-array detection. FA and internal standard were separated completely under the condition described as above. FA was linear in the range of (40.16-8032 ng/ml) (r = 0.9975). The CV was less than 10%, the average recovery was 100.3%, and the limit concentration in serum was 25.1 ng/ml. PK was in accordance with open bicameral model. This method can be applied to clinical pharmacokinetic study of FA.
NASA Astrophysics Data System (ADS)
Kamarudin, A. F.; Noh, M. S. Md; Mokhatar, S. N.; Anuar, M. A. Mohd; Ibrahim, A.; Ibrahim, Z.; Daud, M. E.
2018-04-01
Ambient vibration (AV) technique is widely used nowadays for ground fundamental frequency prediction. This technique is easy, quick, non-destructive, less operator required and reliable result. The input motions of ambient vibration are originally collected from surrounding natural and artificial excitations. But, careful data acquisition controlled must be implemented to reduce the intrusion of short period noise that could imply the quality of frequency prediction of an investigated site. In this study, investigation on the primary noise intrusion under peak (morning, afternoon and evening) and off peak (early morning) traffic flows (only 8 meter from sensor to road shoulder) against the stability and quality of ground fundamental frequency prediction were carried out. None of specific standard is available for AV data acquisition and processing. Thus, some field and processing parameters recommended by previous studies and guideline were considered. Two units of 1 Hz tri-axial seismometer sensor were closely positioned in front of the main entrance Universiti Tun Hussein Onn Malaysia. 15 minutes of recording length were taken during peak and off peak periods of traffic flows. All passing vehicles were counted and grouped into four classes. Three components of ambient vibration time series recorded in the North-South: NS, East-West: EW and vertical: UD directions were automatically computed into Horizontal to Vertical Spectral Ratio (HVSR), by using open source software of GEOPSY for fundamental ground frequency, Fo determination. Single sharp peak pattern of HVSR curves have been obtained at peak frequencies between 1.33 to 1.38 Hz which classified under soft to dense soil classification. Even identical HVSR curves pattern with close frequencies prediction were obtained under both periods of AV measurement, however the total numbers of stable and quality windows selected for HVSR computation were significantly different but both have satisfied the requirement given by SESAME (2004) guideline. Besides, the second peak frequencies from the early morning HVSR curve was clearly indicated between 8.23 to 8.55 Hz at very low amplitude (Ao < 2), but it should be neglected according to the similar guideline criteria. In conclusion, the ground fundamental frequency using HVSR method was successfully determined by 1 Hz seismometer instrument with recommended to specific parameters consideration on field as well as data processing, without disruption from the nearest traffic excitations.
Koh, Dong-Wan; Park, Jae-Woong; Lim, Jung-Hoon; Yea, Myeong-Jai; Bang, Dae-Young
2018-02-01
A novel, rapid, simultaneous analysis method for five sugars (fructose, glucose, sucrose, maltose, and lactose) and eight sugar alcohols (erythritol, xylitol, sorbitol, mannitol, inositol, maltitol, lactitol, and isomalt) was developed using UPLC-ELSD, without derivatization. The analysis conditions, including the gradient conditions, modifier concentration and column length, were optimized. Thirteen sugars and sugar alcohols were separated well and the resolution of their peaks was above 1.0. Their optimum analysis condition can be analyzed within 15min. Standard curves for sugars and sugar alcohols with concentrations of 5.0-0.1% and 2.0-0.05% are presented herein, and their correlation coefficients are found to be above 0.999 and the limit of detection (LOD) was around 0.006-0.018%. This novel analysis system can be used for foodstuffs such as candy, chewing gum, jelly, chocolate, processed chocolate products, and snacks containing 0.21-46.41% of sugars and sugar alcohols. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Zhang, Hong-yan
2016-03-01
CdS nanocrystals have been successfully grown on porous silicon (PS) by sol-gel method. The plan-view field emission scanning electron microscopy (FESEM) shows that the pore size of PS is smaller than 5 μm in diameter and the agglomerates of CdS are broadly distributed on the surface of PS substrate. With the increase of annealing time, the CdS nanoparticles grow in both length and diameter along the preferred orientation. The cross-sectional FESEM images of ZnO/PS show that CdS nanocrystals are uniformly penetrated into all PS layers and adhere to them very well. photoluminescence (PL) spectra demonstrate that the intensity of PL peak located at about 425 nm has almost no change after the annealing time increases. The range of emission wavelength of CdS/PS is from 425 nm to 455 nm and the PL intensity is decreasing with the annealing temperature increasing from 100 °C to 200 °C.
Application of aerial photography to the study of small scale upper ocean phenomena
NASA Technical Reports Server (NTRS)
Ichiye, T.; Carnes, M.
1981-01-01
The industrial waste dumped 180 n. miles south of Galveston was monitored in July 1977 by water sampling, hydrographic measurements, acoustic tracking on board two vessels, and by aerial photography. The plume of the waste diffused vertically and horizontally. Photodensitometry of aerial photos of the plume showed lateral dispersion of the plume in agreement with two other methods: acoustic tracking of the waste suspensoid and transmissometer sampling. In addition, the method showed small scale features like the lateral and longitudinal variations in the photodensity, indicating the waste concentration. This waste concentration showed periodic changes in its axial distance, with the spectral peak at about 160 m wave length. It shows a sharp increase at the windward edge of the plume as do the acoustic records. This phenomenon is explained in terms of the shearing current near the surface together with vertical diffusion. The periodic change along the axis is explained in terms of the Langmuir circulation and in terms of internal ship waves.
Correction factors to convert microdosimetry measurements in silicon to tissue in 12C ion therapy.
Bolst, David; Guatelli, Susanna; Tran, Linh T; Chartier, Lachlan; Lerch, Michael L F; Matsufuji, Naruhiro; Rosenfeld, Anatoly B
2017-03-21
Silicon microdosimetry is a promising technology for heavy ion therapy (HIT) quality assurance, because of its sub-mm spatial resolution and capability to determine radiation effects at a cellular level in a mixed radiation field. A drawback of silicon is not being tissue-equivalent, thus the need to convert the detector response obtained in silicon to tissue. This paper presents a method for converting silicon microdosimetric spectra to tissue for a therapeutic 12 C beam, based on Monte Carlo simulations. The energy deposition spectra in a 10 μm sized silicon cylindrical sensitive volume (SV) were found to be equivalent to those measured in a tissue SV, with the same shape, but with dimensions scaled by a factor κ equal to 0.57 and 0.54 for muscle and water, respectively. A low energy correction factor was determined to account for the enhanced response in silicon at low energy depositions, produced by electrons. The concept of the mean path length [Formula: see text] to calculate the lineal energy was introduced as an alternative to the mean chord length [Formula: see text] because it was found that adopting Cauchy's formula for the [Formula: see text] was not appropriate for the radiation field typical of HIT as it is very directional. [Formula: see text] can be determined based on the peak of the lineal energy distribution produced by the incident carbon beam. Furthermore it was demonstrated that the thickness of the SV along the direction of the incident 12 C ion beam can be adopted as [Formula: see text]. The tissue equivalence conversion method and [Formula: see text] were adopted to determine the RBE 10 , calculated using a modified microdosimetric kinetic model, applied to the microdosimetric spectra resulting from the simulation study. Comparison of the RBE 10 along the Bragg peak to experimental TEPC measurements at HIMAC, NIRS, showed good agreement. Such agreement demonstrates the validity of the developed tissue equivalence correction factors and of the determination of [Formula: see text].
Variable length adjacent partitioning for PTS based PAPR reduction of OFDM signal
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ibraheem, Zeyid T.; Rahman, Md. Mijanur; Yaakob, S. N.
2015-05-15
Peak-to-Average power ratio (PAPR) is a major drawback in OFDM communication. It leads the power amplifier into nonlinear region operation resulting into loss of data integrity. As such, there is a strong motivation to find techniques to reduce PAPR. Partial Transmit Sequence (PTS) is an attractive scheme for this purpose. Judicious partitioning the OFDM data frame into disjoint subsets is a pivotal component of any PTS scheme. Out of the existing partitioning techniques, adjacent partitioning is characterized by an attractive trade-off between cost and performance. With an aim of determining effects of length variability of adjacent partitions, we performed anmore » investigation into the performances of a variable length adjacent partitioning (VL-AP) and fixed length adjacent partitioning in comparison with other partitioning schemes such as pseudorandom partitioning. Simulation results with different modulation and partitioning scenarios showed that fixed length adjacent partition had better performance compared to variable length adjacent partitioning. As expected, simulation results showed a slightly better performance of pseudorandom partitioning technique compared to fixed and variable adjacent partitioning schemes. However, as the pseudorandom technique incurs high computational complexities, adjacent partitioning schemes were still seen as favorable candidates for PAPR reduction.« less
[A peak recognition algorithm designed for chromatographic peaks of transformer oil].
Ou, Linjun; Cao, Jian
2014-09-01
In the field of the chromatographic peak identification of the transformer oil, the traditional first-order derivative requires slope threshold to achieve peak identification. In terms of its shortcomings of low automation and easy distortion, the first-order derivative method was improved by applying the moving average iterative method and the normalized analysis techniques to identify the peaks. Accurate identification of the chromatographic peaks was realized through using multiple iterations of the moving average of signal curves and square wave curves to determine the optimal value of the normalized peak identification parameters, combined with the absolute peak retention times and peak window. The experimental results show that this algorithm can accurately identify the peaks and is not sensitive to the noise, the chromatographic peak width or the peak shape changes. It has strong adaptability to meet the on-site requirements of online monitoring devices of dissolved gases in transformer oil.
Moritake, Y.; Kanamori, Y.; Hane, K.
2016-01-01
We demonstrated fine emission wavelength tuning of quantum dot (QD) fluorescence by fine structural control of optical metamaterials with Fano resonance. An asymmetric-double-bar (ADB), which was composed of only two bars with slightly different bar lengths, was used to obtain Fano resonance in the optical region. By changing the short bar length of ADB structures with high dimensional accuracy in the order of 10 nm, resonant wavelengths of Fano resonance were controlled from 1296 to 1416 nm. Fluorescence of QDs embedded in a polymer layer on ADB metamaterials were modified due to coupling to Fano resonance and fine tuning from 1350 to 1376 nm was observed. Wavelength tuning of modified fluorescence was reproduced by analysis using absorption peaks of Fano resonance. Tuning range of modified fluorescence became narrow, which was interpreted by a simple Gaussian model and resulted from comparable FWHM in QD fluorescence and Fano resonant peaks. The results will help the design and fabrication of metamaterial devices with fluorophores such as light sources and biomarkers. PMID:27622503
Turing mechanism for homeostatic control of synaptic density during C. elegans growth
NASA Astrophysics Data System (ADS)
Brooks, Heather A.; Bressloff, Paul C.
2017-07-01
We propose a mechanism for the homeostatic control of synapses along the ventral cord of Caenorhabditis elegans during development, based on a form of Turing pattern formation on a growing domain. C. elegans is an important animal model for understanding cellular mechanisms underlying learning and memory. Our mathematical model consists of two interacting chemical species, where one is passively diffusing and the other is actively trafficked by molecular motors, which switch between forward and backward moving states (bidirectional transport). This differs significantly from the standard mechanism for Turing pattern formation based on the interaction between fast and slow diffusing species. We derive evolution equations for the chemical concentrations on a slowly growing one-dimensional domain, and use numerical simulations to demonstrate the insertion of new concentration peaks as the length increases. Taking the passive component to be the protein kinase CaMKII and the active component to be the glutamate receptor GLR-1, we interpret the concentration peaks as sites of new synapses along the length of C. elegans, and thus show how the density of synaptic sites can be maintained.
A preliminary analysis of low frequency pressure oscillations in hybrid rocket motors
NASA Technical Reports Server (NTRS)
Jenkins, Rhonald M.
1994-01-01
Past research with hybrid rockets has suggested that certain motor operating conditions are conducive to the formation of pressure oscillations, or flow instabilities, within the motor combustion chamber. These combustion-related vibrations or pressure oscillations may be encountered in virtually any type of rocket motor and typically fall into three frequency ranges: low frequency oscillations (0-300 Hz); intermediate frequency oscillations (400-1000 Hz); and high frequency oscillations (greater than 1000 Hz). In general, combustion instability is characterized by organized pressure oscillations occurring at well-defined intervals with pressure peaks that may maintain themselves, grow, or die out. Usually, such peaks exceed +/- 5% of the mean chamber pressure. For hybrid motors, these oscillations have been observed to grow to a limiting amplitude which may be dependent on factors such as fuel characteristics, oxidizer injector characteristics, average chamber pressure, oxidizer mass flux, combustion chamber length, and grain geometry. The approach taken in the present analysis is to develop a modified chamber length, L, instability theory which accounts for the relationship between pressure and oxidizer to fuel concentration ratio in the motor.
NASA Astrophysics Data System (ADS)
Cheng, Fuqiang; Hong, Yanji; Li, Qian; Wen, Ming
2011-11-01
Laser thrusters with a single nozzle, e.g. parabolic or conical, failed to constrict the flow field of high pressure effectively, resulting in poor propulsive performance. Under the condition of air-breathing mode, parabolic thruster models with an elongate cylinder nozzle were studied numerically by building a physical computation model. Initially, to verify the computation model, the influence of cylinder length on the momentum coupling coefficient was computed and compared with the experiments, which shows a good congruence. A model of diameter 20 mm and cylindrical length 80 mm obtains about 627.7 N/MW at single pulse energy density 1.5 J/cm2. Then, the influence of expanding angle of the parabolic nozzle on propulsion performance was gained for different laser pulse energies, and the evolution process of the flow field was analyzed. The results show: as the expanding angel increases, the momentum coupling coefficient increases remarkably at first and descends relative slowly after reaching a peak value; moreover, the peak positions stay constant around 33° with little variation when laser energy differs.
Loaded delay lines for future RF pulse compression systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, R.M.; Wilson, P.B.; Kroll, N.M.
1995-05-01
The peak power delivered by the klystrons in the NLCRA (Next Linear Collider Test Accelerator) now under construction at SLAC is enhanced by a factor of four in a SLED-II type of R.F. pulse compression system (pulse width compression ratio of six). To achieve the desired output pulse duration of 250 ns, a delay line constructed from a 36 m length of circular waveguide is used. Future colliders, however, will require even higher peak power and larger compression factors, which favors a more efficient binary pulse compression approach. Binary pulse compression, however, requires a line whose delay time is approximatelymore » proportional to the compression factor. To reduce the length of these lines to manageable proportions, periodically loaded delay lines are being analyzed using a generalized scattering matrix approach. One issue under study is the possibility of propagating two TE{sub o} modes, one with a high group velocity and one with a group velocity of the order 0.05c, for use in a single-line binary pulse compression system. Particular attention is paid to time domain pulse degradation and to Ohmic losses.« less
Fatigue affects peak joint torque angle in hamstrings but not in quadriceps.
Coratella, Giuseppe; Bellin, Giuseppe; Beato, Marco; Schena, Federico
2015-01-01
Primary aim of this study was to investigate peak joint torque angle (i.e. the angle of peak torque) changes recorded during an isokinetic test before and after a fatiguing soccer match simulation. Secondarily we want to investigate functional Hecc:Qconc and conventional Hconc:Qconc ratio changes due to fatigue. Before and after a standardised soccer match simulation, twenty-two healthy male amateur soccer players performed maximal isokinetic strength tests both for hamstrings and for quadriceps muscles at 1.05 rad · s(‒1), 3.14 rad · s(‒1) and 5.24 rad · s(‒1). Peak joint torque angle, peak torque and both functional Hecc:Qconc and conventional Hconc:Qconc ratios were examined. Both dominant and non-dominant limbs were tested. Peak joint torque angle significantly increased only in knee flexors. Both eccentric and concentric contractions resulted in such increment, which occurred in both limbs. No changes were found in quadriceps peak joint torque angle. Participants experienced a significant decrease in torque both in hamstrings and in quadriceps. Functional Hecc:Qconc ratio was lower only in dominant limb at higher velocities, while Hconc:Qconc did not change. This study showed after specific fatiguing task changes in hamstrings only torque/angle relationship. Hamstrings injury risk could depend on altered torque when knee is close to extension, coupled with a greater peak torque decrement compared to quadriceps. These results suggest the use eccentric based training to prevent hamstrings shift towards shorter length.
NASA Astrophysics Data System (ADS)
Lieou, Charles K. C.; Elbanna, Ahmed E.; Carlson, Jean M.
2013-03-01
Sacrificial bonds and hidden length in structural molecules account for the greatly increased fracture toughness of biological materials compared to synthetic materials without such structural features, by providing a molecular-scale mechanism of energy dissipation. One example of occurrence of sacrificial bonds and hidden length is in the polymeric glue connection between collagen fibrils in animal bone. In this talk, we propose a simple kinetic model that describes the breakage of sacrificial bonds and the revelation of hidden length, based on Bell's theory. We postulate a master equation governing the rates of bond breakage and formation, at the mean-field level, allowing for the number of bonds and hidden lengths to take up non-integer values between successive, discrete bond-breakage events. This enables us to predict the mechanical behavior of a quasi-one-dimensional ensemble of polymers at different stretching rates. We find that both the rupture peak heights and maximum stretching distance increase with the stretching rate. In addition, our theory naturally permits the possibility of self-healing in such biological structures.
NASA Astrophysics Data System (ADS)
Seip, Knut L.; Grøn, Øyvind
2017-02-01
We apply a novel method based upon "before" and "after" relationships to investigate and quantify interconnections between global temperature anomaly (GTA), as response variable, and greenhouse gases (CO2) and total solar irradiance (TSI) as candidate causal variables for the period 1880 to 2010. The most likely interpretations of our results for the 6 to 8 years cyclic components of the variables are that during the period 1929 to 1936, CO2 significantly leads GTA. However, during the period 1960-2003, GTA apparently leads CO2, that is, the peaks (and troughs) in GTA are in front of, and close to, the peaks (and troughs) in CO2. For time windows outside these periods, we did not find significant before or after-relations. An alternative interpretation is that there is a shift between short (≈1.5 year) and long (≈5 years) durations between cause and effect. Relationships between GTA and TSI suggest that "inertia" of the global sea, land, and atmosphere system leads to delays longer than half their common cycle length of about 10 years. Based on the interaction patterns between the variables GTA, CO2, and TSI, we suggest the possibility that a new regime for how the variables interact started around 1960. From trend forms, and not considering physical mechanisms, we found that the trend in CO2 contributes ≈ 90 %, and the trend in TSI ≈ 10 %, to the trend in GTA during the last 130 years.
Method for compression of data using single pass LZSS and run-length encoding
Berlin, G.J.
1994-01-01
A method used preferably with LZSS-based compression methods for compressing a stream of digital data. The method uses a run-length encoding scheme especially suited for data strings of identical data bytes having large run-lengths, such as data representing scanned images. The method reads an input data stream to determine the length of the data strings. Longer data strings are then encoded in one of two ways depending on the length of the string. For data strings having run-lengths less than 18 bytes, a cleared offset and the actual run-length are written to an output buffer and then a run byte is written to the output buffer. For data strings of 18 bytes or longer, a set offset and an encoded run-length are written to the output buffer and then a run byte is written to the output buffer. The encoded run-length is written in two parts obtained by dividing the run length by a factor of 255. The first of two parts of the encoded run-length is the quotient; the second part is the remainder. Data bytes that are not part of data strings of sufficient length are written directly to the output buffer.
Method for compression of data using single pass LZSS and run-length encoding
Berlin, Gary J.
1997-01-01
A method used preferably with LZSS-based compression methods for compressing a stream of digital data. The method uses a run-length encoding scheme especially suited for data strings of identical data bytes having large run-lengths, such as data representing scanned images. The method reads an input data stream to determine the length of the data strings. Longer data strings are then encoded in one of two ways depending on the length of the string. For data strings having run-lengths less than 18 bytes, a cleared offset and the actual run-length are written to an output buffer and then a run byte is written to the output buffer. For data strings of 18 bytes or longer, a set offset and an encoded run-length are written to the output buffer and then a run byte is written to the output buffer. The encoded run-length is written in two parts obtained by dividing the run length by a factor of 255. The first of two parts of the encoded run-length is the quotient; the second part is the remainder. Data bytes that are not part of data strings of sufficient length are written directly to the output buffer.
Siff, Lauren N; Hill, Audra J; Walters, Samantha J; Walters, Ginny; Walters, Mark D
2018-05-02
The aim oft his study was to compare the effects of 10 common exercises to traditional pelvic floor muscle (PFM) contractions (Kegel) on levator hiatus (LH) area and PFM length and strength. This is a cross-sectional study of 15 healthy postpartum women. Ten exercises were studied. These were common variations of leg, core, and back exercises used in yoga, Pilates, strength training, and physical therapy. Each participant performed all 10 exercises at a single visit in 2 examination settings: transperineal ultrasound and perineometry. Ultrasound measured the LH area and PFM length, and perineometry measured the muscle strength (peak squeeze pressure). Kegel generates an increase in squeeze pressure (24.3 cm H2O), shortens the muscles (-0.46 cm) and narrows the LH (-0.13 cm). The bird-dog and plank exercises were not different from Kegel in any measurement. While the leg-lift ultrasound dimensions are similar to Kegel, leg lifts generated peak squeeze pressures stronger than any other exercise (including Kegel). Whereas ultrasound dimensions were similar to Kegel, tucked and untucked squats and thigh adductions generated weaker contractions than Kegel. While crunch generated a squeeze pressure similar to Kegel, the ultrasound dimensions showed a significantly wider LH and longer muscle than Kegel. Bridge, clam, and plié exercises affected the PFMs differently than Kegel in all measures. Bird-dog, plank, and leg-lift exercises should be evaluated as alternative exercises to Kegel as they affect PFM strength and length and LH area similarly to Kegel, and leg lifts generate a stronger contraction than Kegel.
Exact extraction method for road rutting laser lines
NASA Astrophysics Data System (ADS)
Hong, Zhiming
2018-02-01
This paper analyzes the importance of asphalt pavement rutting detection in pavement maintenance and pavement administration in today's society, the shortcomings of the existing rutting detection methods are presented and a new rutting line-laser extraction method based on peak intensity characteristic and peak continuity is proposed. The intensity of peak characteristic is enhanced by a designed transverse mean filter, and an intensity map of peak characteristic based on peak intensity calculation for the whole road image is obtained to determine the seed point of the rutting laser line. Regarding the seed point as the starting point, the light-points of a rutting line-laser are extracted based on the features of peak continuity, which providing exact basic data for subsequent calculation of pavement rutting depths.
Method and system for calibrating acquired spectra for use in spectral analysis
Reber, Edward L.; Rohde, Kenneth W.; Blackwood, Larry G.
2010-09-14
A method for calibrating acquired spectra for use in spectral analysis includes performing Gaussian peak fitting to spectra acquired by a plurality of NaI detectors to define peak regions. A Na and annihilation doublet may be located among the peak regions. A predetermined energy level may be applied to one of the peaks in the doublet and a location of a hydrogen peak may be predicted based on the location of at least one of the peaks of the doublet. Control systems for calibrating spectra are also disclosed.
On a hierarchy of nonlinearly dispersive generalized Korteweg - de Vries evolution equations
Christov, Ivan C.
2015-08-20
We propose a hierarchy of nonlinearly dispersive generalized Korteweg–de Vries (KdV) evolution equations based on a modification of the Lagrangian density whose induced action functional the KdV equation extremizes. Two recent nonlinear evolution equations describing wave propagation in certain generalized continua with an inherent material length scale are members of the proposed hierarchy. Like KdV, the equations from the proposed hierarchy possess Hamiltonian structure. Unlike KdV, the solutions to these equations can be compact (i.e., they vanish outside of some open interval) and, in addition, peaked. Implicit solutions for these peaked, compact traveling waves (“peakompactons”) are presented.
FTIR quantification of industrial hydraulic fluids in perchloroethylene
NASA Technical Reports Server (NTRS)
Mehta, Narinder K.
1993-01-01
The purpose of this summer research project was to investigate whether perchloroethylene can be used as a solvent for the quantitative analysis of industrial hydraulic fluids by infrared spectroscopy employing Beer's law. Standard calibration curves using carbon-hydrogen stretching (generic) and ester absorption peaks were prepared for a series of standard dilutions at low ppm levels of concentration of seven hydraulic fluids in perchloroethylene. The absorbance spectras were recorded with 1.5-10 mm fixed and variable path length sample cells made of potassium bromide. The results indicate that using ester infrared spectral peak, it is possible to detect about 20 ppm of the hydraulic fluid in perchloroethylene.
Complementary periodic diffracting metallic nanohole and nanodipole arrays in the mid-infrared range
NASA Astrophysics Data System (ADS)
Ye, Yong-Hong; Zhang, Jia-Yu; Feng Ma, Hui; Yao, Jie; Wang, Xudong
2012-10-01
Metallic nanohole arrays and metallic nanodipole arrays are fabricated and experimentally characterized. A complementary response is observed in both transmission and reflection. For the metallic nanohole arrays, a peak (dip) in transmission (reflection) is observed at resonance whereas the metallic nanodipole arrays display a dip (peak) in transmission (reflection). The resonant frequency of both the metallic nanohole arrays and the nanodipole arrays depends on the dipole arm length, the incident angle, and the period. The resonant position of the nanohole arrays matches that of its complement, which means that Babinet's principle nearly holds for these structures in the mid-infrared region.
Brennan, Scott F; Cresswell, Andrew G; Farris, Dominic J; Lichtwark, Glen A
2017-11-07
Ultrasonography is a useful technique to study muscle contractions in vivo, however larger muscles like vastus lateralis may be difficult to visualise with smaller, commonly used transducers. Fascicle length is often estimated using linear trigonometry to extrapolate fascicle length to regions where the fascicle is not visible. However, this approach has not been compared to measurements made with a larger field of view for dynamic muscle contractions. Here we compared two different single-transducer extrapolation methods to measure VL muscle fascicle length to a direct measurement made using two synchronised, in-series transducers. The first method used pennation angle and muscle thickness to extrapolate fascicle length outside the image (extrapolate method). The second method determined fascicle length based on the extrapolated intercept between a fascicle and the aponeurosis (intercept method). Nine participants performed maximal effort, isometric, knee extension contractions on a dynamometer at 10° increments from 50 to 100° of knee flexion. Fascicle length and torque were simultaneously recorded for offline analysis. The dual transducer method showed similar patterns of fascicle length change (overall mean coefficient of multiple correlation was 0.76 and 0.71 compared to extrapolate and intercept methods respectively), but reached different absolute lengths during the contractions. This had the effect of producing force-length curves of the same shape, but each curve was shifted in terms of absolute length. We concluded that dual transducers are beneficial for studies that examine absolute fascicle lengths, whereas either of the single transducer methods may produce similar results for normalised length changes, and repeated measures experimental designs. Copyright © 2017 Elsevier Ltd. All rights reserved.
Optimization for Single-Spike X-Ray FELs at LCLS with a Low Charge Beam
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, L.; Ding, Y.; Huang, Z.
2011-12-14
The Linac Coherent Light Source is an x-ray free-electron laser at the SLAC National Accelerator Laboratory, which is operating at x-ray wavelengths of 20-1.2 Angstrom with peak brightness nearly ten orders of magnitude beyond conventional synchrotron radiation sources. At the low charge operation mode (20 pC), the x-ray pulse length can be <10 fs. In this paper we report our numerical optimization and simulations to produce even shorter x-ray pulses by optimizing the machine and undulator setup at 20 pC charge. In the soft x-ray regime, with combination of slotted-foil or undulator taper, a single spike x-ray pulse is achievablemore » with peak FEL power of a few 10s GW. Linac Coherent Light Source (LCLS), the world's first hard x-ray Free electron laser (FEL), has started operation since 2009. With nominal operation charge of 250 pC, the generated x-ray pulse length is from 70 fs to a few hundred fs. This marks the beginning of a new era of ultrashort x-ray sciences. In addition, a low charge (20pC) operation mode has also been established. Since the collective effects are reduced at the low charge mode, we can increase the compression factor and still achieve a few kA peak current. The expected electron beam and x-ray pulses are less than 10 fs. There are growing interests in even shorter x-ray pulses, such as fs to sub-fs regime. One of the simple solutions is going to even lower charge. As discussed, single-spike x-ray pulses can be generated using 1 pC charge. However, this charge level is out of the present LCLS diagnostic range. 20 pC is a reasonable operation charge at LCLS, based on the present diagnostic system. At 20 pC in the soft x-ray wavelength regime, we have experimentally demonstrated that FEL can work at undercompression or over-compression mode, such as 1 degree off the full-compression; at full-compression, however, there is almost no lasing. In hard x-ray wavelength regime, we observed that there are reasonable photons generated even at full-compression mode, although the photon number is less than that from under-compression or over-compression mode. Since we cannot measure the x-ray pulse length at this time scale, the machine is typically optimized for generating maximum photons, not minimum pulse length. In this paper, we study the methods of producing femtosecond (or single-spike) x-ray pulses at LCLS with 20 pC charge, based on start-to-end simulations. Figure 1 shows a layout of LCLS. The compression in the second bunch compressor (BC2) determines the final e-beam bunch length. However, the laser heater, dog-leg after the main linac (DL2) and collective effects also affect the final bunch length. To adjust BC2 compression, we can either change the L2 phase or BC2 R{sub 56}. In this paper we only tune L2 phase while keep BC2 R{sub 56} fixed. For the start-to-end simulations, we used IMPACT-T and ELEGANT tracking from the photocathode to the entrance of the undulator, after that the FEL radiation was simulated with GENESIS. IMPACT-T tracks about 10{sup 6} particles in the injector part until 135 MeV, including 3D space charge force. The output particles from IMPACT-T are smoothed and increased to 12 x 10{sup 6} to reduce high-frequency numerical noise for subsequent ELEGANT simulations, which include linear and nonlinear transport effects, a 1D transient model of CSR, and longitudinal space charge effects, as well as geometric and resistive wake fields in the accelerator. In GENESIS part, the longitudinal wake field from undulator chamber and longitudinal space field are also included.« less
Evolutionary advantage via common action of recombination and neutrality
NASA Astrophysics Data System (ADS)
Saakian, David B.; Hu, Chin-Kun
2013-11-01
We investigate evolution models with recombination and neutrality. We consider the Crow-Kimura (parallel) mutation-selection model with the neutral fitness landscape, in which there is a central peak with high fitness A, and some of 1-point mutants have the same high fitness A, while the fitness of other sequences is 0. We find that the effect of recombination and neutrality depends on the concrete version of both neutrality and recombination. We consider three versions of neutrality: (a) all the nearest neighbor sequences of the peak sequence have the same high fitness A; (b) all the l-point mutations in a piece of genome of length l≥1 are neutral; (c) the neutral sequences are randomly distributed among the nearest neighbors of the peak sequences. We also consider three versions of recombination: (I) the simple horizontal gene transfer (HGT) of one nucleotide; (II) the exchange of a piece of genome of length l, HGT-l; (III) two-point crossover recombination (2CR). For the case of (a), the 2CR gives a rather strong contribution to the mean fitness, much stronger than that of HGT for a large genome length L. For the random distribution of neutral sequences there is a critical degree of neutrality νc, and for μ<μc and (μc-μ) is not large, the 2CR suppresses the mean fitness while HGT increases it; for ν much larger than νc, the 2CR and HGT-l increase the mean fitness larger than that of the HGT. We also consider the recombination in the case of smooth fitness landscapes. The recombination gives some advantage in the evolutionary dynamics, where recombination distinguishes clearly the mean-field-like evolutionary factors from the fluctuation-like ones. By contrast, mutations affect the mean-field-like and fluctuation-like factors similarly. Consequently, recombination can accelerate the non-mean-field (fluctuation) type dynamics without considerably affecting the mean-field-like factors.
A comparison of two methods for measuring vessel length in woody plants.
Pan, Ruihua; Geng, Jing; Cai, Jing; Tyree, Melvin T
2015-12-01
Vessel lengths are important to plant hydraulic studies, but are not often reported because of the time required to obtain measurements. This paper compares the fast dynamic method (air injection method) with the slower but traditional static method (rubber injection method). Our hypothesis was that the dynamic method should yield a larger mean vessel length than the static method. Vessel length was measured by both methods in current year stems of Acer, Populus, Vitis and Quercus representing short- to long-vessel species. The hypothesis was verified. The reason for the consistently larger values of vessel length is because the dynamic method measures air flow rates in cut open vessels. The Hagen-Poiseuille law predicts that the air flow rate should depend on the product of number of cut open vessels times the fourth power of vessel diameter. An argument is advanced that the dynamic method is more appropriate because it measures the length of the vessels that contribute most to hydraulic flow. If all vessels had the same vessel length distribution regardless of diameter, then both methods should yield the same average length. This supports the hypothesis that large-diameter vessels might be longer than short-diameter vessels in most species. © 2015 John Wiley & Sons Ltd.
Odendaal, Lizelle J; Jacobs, David S
2011-05-01
We investigated intraspecific variation in echolocation calls of the Cape horseshoe bat, Rhinolophus capensis, by comparing echolocation and associated morphological parameters among individuals from three populations of this species. The populations were situated in the center and at the western and eastern limits of the distribution of R. capensis. The latter two populations were situated in ecotones between vegetation biomes. Ecotone populations deviated slightly from the allometric relationship between body size and peak frequency for the genus, and there was no relationship between these variables within R. capensis. Nasal chamber length was the best predictor of peak frequency but not correlated with body size. The evolution of echolocation thus appears to have been uncoupled from body size in R. capensis. Furthermore, females used higher frequencies than males, which imply a potential social role for peak frequency. The differences in peak frequency may have originated from random founder effects and then compounded by genetic drift and/or natural selection. The latter may have acted directly on peak frequency altering skull parameters involved in echolocation independently of body size, resulting in the evolution of local acoustic signatures.
NASA Technical Reports Server (NTRS)
Tan, Lun C.; Malandraki, Olga E.; Reames, Donald; NG, Chee K.; Wang, Linghua; Patsou, Ioanna; Papaioannou, Athanasios
2013-01-01
We have examined the Wind/3DP/SST electron and Wind/EPACT/LEMT ion data to investigate the path length difference between solar electrons and ions in the ground-level enhancement (GLE) events in solar cycle 23. Assuming that the onset time of metric type II or decameter-hectometric (DH) type III radio bursts is the solar release time of non-relativistic electrons, we have found that within an error range of plus or minus 10% the deduced path length of low-energy (approximately 27 keV) electrons from their release site near the Sun to the 1 AU observer is consistent with the ion path length deduced by Reames from the onset time analysis. In addition, the solar longitude distribution and IMF topology of the GLE events examined are in favor of the coronal mass ejection-driven shock acceleration origin of observed non-relativistic electrons.We have also found an increase of electron path lengths with increasing electron energies. The increasing rate of path lengths is correlated with the pitch angle distribution (PAD) of peak electron intensities locally measured, with a higher rate corresponding to a broader PAD. The correlation indicates that the path length enhancement is due to the interplanetary scattering experienced by first arriving electrons. The observed path length consistency implies that the maximum stable time of magnetic flux tubes, along which particles transport, could reach 4.8 hr.
Data preprocessing method for liquid chromatography-mass spectrometry based metabolomics.
Wei, Xiaoli; Shi, Xue; Kim, Seongho; Zhang, Li; Patrick, Jeffrey S; Binkley, Joe; McClain, Craig; Zhang, Xiang
2012-09-18
A set of data preprocessing algorithms for peak detection and peak list alignment are reported for analysis of liquid chromatography-mass spectrometry (LC-MS)-based metabolomics data. For spectrum deconvolution, peak picking is achieved at the selected ion chromatogram (XIC) level. To estimate and remove the noise in XICs, each XIC is first segmented into several peak groups based on the continuity of scan number, and the noise level is estimated by all the XIC signals, except the regions potentially with presence of metabolite ion peaks. After removing noise, the peaks of molecular ions are detected using both the first and the second derivatives, followed by an efficient exponentially modified Gaussian-based peak deconvolution method for peak fitting. A two-stage alignment algorithm is also developed, where the retention times of all peaks are first transferred into the z-score domain and the peaks are aligned based on the measure of their mixture scores after retention time correction using a partial linear regression. Analysis of a set of spike-in LC-MS data from three groups of samples containing 16 metabolite standards mixed with metabolite extract from mouse livers demonstrates that the developed data preprocessing method performs better than two of the existing popular data analysis packages, MZmine2.6 and XCMS(2), for peak picking, peak list alignment, and quantification.
A Data Pre-processing Method for Liquid Chromatography Mass Spectrometry-based Metabolomics
Wei, Xiaoli; Shi, Xue; Kim, Seongho; Zhang, Li; Patrick, Jeffrey S.; Binkley, Joe; McClain, Craig; Zhang, Xiang
2012-01-01
A set of data pre-processing algorithms for peak detection and peak list alignment are reported for analysis of LC-MS based metabolomics data. For spectrum deconvolution, peak picking is achieved at selected ion chromatogram (XIC) level. To estimate and remove the noise in XICs, each XIC is first segmented into several peak groups based on the continuity of scan number, and the noise level is estimated by all the XIC signals, except the regions potentially with presence of metabolite ion peaks. After removing noise, the peaks of molecular ions are detected using both the first and the second derivatives, followed by an efficient exponentially modified Gaussian-based peak deconvolution method for peak fitting. A two-stage alignment algorithm is also developed, where the retention times of all peaks are first transferred into z-score domain and the peaks are aligned based on the measure of their mixture scores after retention time correction using a partial linear regression. Analysis of a set of spike-in LC-MS data from three groups of samples containing 16 metabolite standards mixed with metabolite extract from mouse livers, demonstrates that the developed data pre-processing methods performs better than two of the existing popular data analysis packages, MZmine2.6 and XCMS2, for peak picking, peak list alignment and quantification. PMID:22931487
Method and system for detecting an explosive
Reber, Edward L.; Rohde, Kenneth W.; Blackwood, Larry G.
2010-12-07
A method and system for detecting at least one explosive in a vehicle using a neutron generator and a plurality of NaI detectors. Spectra read from the detectors is calibrated by performing Gaussian peak fitting to define peak regions, locating a Na peak and an annihilation peak doublet, assigning a predetermined energy level to one peak in the doublet, and predicting a hydrogen peak location based on a location of at least one peak of the doublet. The spectra are gain shifted to a common calibration, summed for respective groups of NaI detectors, and nitrogen detection analysis performed on the summed spectra for each group.
Zonation of Landslide-Prone Using Microseismic Method and Slope Analysis in Margoyoso, Magelang
NASA Astrophysics Data System (ADS)
Aditya, Muchamad Reza; Fauqi Romadlon, Arriqo’; Agra Medika, Reymon; Alfontius, Yosua; Delva Jannet, Zukhruf; Hartantyo, Eddy
2018-04-01
Margoyoso Village, Salaman Sub-district, Magelang Regency, Central Java is one of the villages that were included in landslide prone areas. The steep slopes and land use in this village were quite apprehensive. There were fractures with 5 cm in width and a length of 50 m. Moreover, these fractures appeared in the home residents. Although the local government has established a disaster response organization, this village is still not getting adequate information about the landslide prone areas. Based on the description before, we conducted research with geophysical methods and geotechnical analysis to minimize the danger of landslides. The geophysical method used in this research was microseismic method and geotechnical analysis. The microseismic measurement and slope stability analysis at Margoyoso village was a step in analysing the landslide-prone zone boundary. The results of this research indicated that landslide potential areas had a low peak ground acceleration values with a range from 36 gal to 46 gal. Measurement of slope stability indicated that a slope angle values between 55°-78° are a potential landslide slope because the soil in this village has very loose properties so it is very easy to move.
Kojima, Chie; Irie, Kotaro; Tada, Tomoko; Tanaka, Naoki
2014-06-01
Dendrimers are synthetic macromolecules with unique structure, which are a potential scaffold for peptides. Elastin is one of the main components of extracellular matrix and a temperature-sensitive biomacromolecule. Previously, Val-Pro-Gly-Val-Gly peptides have been conjugated to a dendrimer for designing an elastin-mimetic dendrimer. In this study, various elastin-mimetic dendrimers using different length peptides and different dendrimer generations were synthesized to control the temperature dependency. The elastin-mimetic dendrimers formed β-turn structure by heating, which was similar to the elastin-like peptides. The elastin-mimetic dendrimers exhibited an inverse phase transition, largely depending on the peptide length and slightly depending on the dendrimer generation. The elastin-mimetic dendrimers formed aggregates after the phase transition. The endothermal peak was observed in elastin-mimetic dendrimers with long peptides, but not with short ones. The peptide length and the dendrimer generation are important factors to tune the temperature dependency on the elastin-mimetic dendrimer. Copyright © 2013 Wiley Periodicals, Inc.
A test of fixed and moving reference point control in posture.
Lee, I-Chieh; Pacheco, Matheus M; Newell, Karl M
2017-01-01
This study investigated two contrasting assumptions of the regulation of posture: namely, fixed and moving reference point control. These assumptions were tested in terms of time-dependent structure and data distribution properties when stability is manipulated. Fifteen male participants performed a tightrope simulated balance task that is, maintaining a tandem stance while holding a pole. Pole length (and mass) and the standing support surface (fixed surface/balance board) were manipulated so as to mechanically change the balance stability. The mean and standard deviation (SD) of COP length were reduced with pole length increment but only in the balance board surface condition. Also, the SampEn was lower with greater pole length for the balance board but not the fixed surface. More than one peak was present in the distribution of COP in the majority of trials. Collectively, the findings provide evidence for a moving reference point in the maintenance of postural stability for quiet standing. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Casalbuoni, S.; Cecilia, A.; Gerstl, S.; Glamann, N.; Grau, A. W.; Holubek, T.; Meuter, C.; de Jauregui, D. Saez; Voutta, R.; Boffo, C.; Gerhard, Th.; Turenne, M.; Walter, W.
2016-11-01
A new cryogen-free full scale (1.5 m long) superconducting undulator with a period length of 15 mm (SCU15) has been successfully tested in the ANKA storage ring. This represents a very important milestone in the development of superconducting undulators for third and fourth generation light sources carried on by the collaboration between the Karlsruhe Institute of Technology and the industrial partner Babcock Noell GmbH. SCU15 is the first full length device worldwide that with beam reaches a higher peak field than what expected with the same geometry (vacuum gap and period length) with an ideal cryogenic permanent magnet undulator built with the best material available PrFeB. After a summary on the design and main parameters of the device, we present here the characterization in terms of spectral properties and the long term operation of the SCU15 in the ANKA storage ring.
Quantifying adsorption-induced deformation of nanoporous materials on different length scales
Morak, Roland; Braxmeier, Stephan; Ludescher, Lukas; Hüsing, Nicola; Reichenauer, Gudrung
2017-01-01
A new in situ setup combining small-angle neutron scattering (SANS) and dilatometry was used to measure water-adsorption-induced deformation of a monolithic silica sample with hierarchical porosity. The sample exhibits a disordered framework consisting of macropores and struts containing two-dimensional hexagonally ordered cylindrical mesopores. The use of an H2O/D2O water mixture with zero scattering length density as an adsorptive allows a quantitative determination of the pore lattice strain from the shift of the corresponding diffraction peak. This radial strut deformation is compared with the simultaneously measured macroscopic length change of the sample with dilatometry, and differences between the two quantities are discussed on the basis of the deformation mechanisms effective at the different length scales. It is demonstrated that the SANS data also provide a facile way to quantitatively determine the adsorption isotherm of the material by evaluating the incoherent scattering contribution of H2O at large scattering vectors. PMID:29021735
NASA Astrophysics Data System (ADS)
Shi, Zhi-Dong; Lin, Jian-Qiang; Bao, Huan-Huan; Liu, Shu; Xiang, Xue-Nong
2008-03-01
A photoelectric measurement system for measuring the beat length of birefringence fiber is set up including a set of rotating-wave-plate polarimeter using single photodiode. And two improved cutback methods suitable for measuring beat-length within millimeter range of high birefringence fiber are proposed through data processing technique. The cut length needs not to be restricted shorter than one centimeter so that the auto-cleaving machine is freely used, and no need to carefully operate the manually cleaving blade with low efficiency and poor success. The first method adopts the parameter-fitting to a saw-tooth function of tried beat length by the criterion of minimum square deviations, without special limitation on the cut length. The second method adopts linear-fitting in the divided length ranges, only restrict condition is the increment between different cut lengths less than one beat-length. For a section of holey high-birefringence fiber, we do experiments respectively by the two methods. The detecting error of beat-length is discussed and the advantage is compared.
Phakthong, Wilaiwan; Liawruangrath, Boonsom; Liawruangrath, Saisunee
2014-12-01
A reversed flow injection (rFI) system was designed and constructed for gallic acid determination. Gallic acid was determined based on the formation of chromogen between gallic acid and rhodanine, resulting in a colored product with a λmax at 520 nm. The optimum conditions for determining gallic acid were also investigated. Optimizations of the experimental conditions were carried out based on the so-call univariate method. The conditions obtained were 0.6% (w/v) rhodanine, 70% (v/v) ethanol, 0.9 mol L(-1) NaOH, 2.0 mL min(-1) flow rate, 75 μL injection loop and 600 cm mixing tubing length, respectively. Comparative optimizations of the experimental conditions were also carried out by multivariate or simplex optimization method. The conditions obtained were 1.2% (w/v) rhodanine, 70% (v/v) ethanol, 1.2 mol L(-1) NaOH, flow rate 2.5 mL min(-1), 75 μL injection loop and 600 cm mixing tubing length, respectively. It was found that the optimum conditions obtained by the former optimization method were mostly similar to those obtained by the latter method. The linear relationship between peak height and the concentration of gallic acid was obtained over the range of 0.1-35.0 mg L(-1) with the detection limit 0.081 mg L(-1). The relative standard deviations were found to be in the ranges 0.46-1.96% for 1, 10, 30 mg L(-1) of gallic acid (n=11). The method has the advantages of simplicity extremely high selectivity and high precision. The proposed method was successfully applied to the determination of gallic acid in longan samples without interferent effects from other common phenolic compounds that might be present in the longan samples collected in northern Thailand. Copyright © 2014 Elsevier B.V. All rights reserved.
Relations for estimating unit-hydrograph parameters in New Mexico
Waltemeyer, Scott D.
2001-01-01
Data collected from 20 U.S. Geological Survey streamflow-gaging stations, most of which were operated in New Mexico between about 1969 and 1977, were used to define hydrograph characteristics for small New Mexico streams. Drainage areas for the gaging stations ranged from 0.23 to 18.2 square miles. Observed values for the hydrograph characteristics were determined for 87 of the most significant rainfall-runoff events at these gaging stations and were used to define regional regression relations with basin characteristics. Regional relations defined lag time (tl), time of concentration (tc), and time to peak (tp) as functions of stream length and basin shape. The regional equation developed for time of concentration for New Mexico agrees well with the Kirpich equation developed for Tennessee. The Kirpich equation is based on stream length and channel slope, whereas the New Mexico equation is based on stream length and basin shape. Both equations, however, underestimate tc when applied to larger basins where tc is greater than about 2 hours. The median ratio between tp and tc for the observed data was 0.66, which equals the value (0.67) recommended by the Natural Resources Conservation Service (formerly the Soil Conservation Service). However, the median ratio between tl and tc was only 0.42, whereas the commonly used ratio is 0.60. A relation also was developed between unit-peak discharge (qu) and time of concentration. The unit-peak discharge relation is similar in slope to the Natural Resources Conservation Service equation, but the equation developed for New Mexico in this study produces estimates of qu that range from two to three times as large as those estimated from the Natural Resources Conservation Service equation. An average value of 833 was determined for the empirical constant Kp. A default value of 484 has been used by the Natural Resources Conservation Service when site-specific data are not available. The use of a lower value of Kp in calculations generally results in a lower peak discharge. A relation between the empirical constant Kp and average channel slope was defined in this study. The predicted Kp values from the equation ranged from 530 to 964 for the 20 flood-hydrograph gaging stations. The standard error of estimate for the equation is 36 percent.
Speich, John E; Wilson, Cameron W; Almasri, Atheer M; Southern, Jordan B; Klausner, Adam P; Ratz, Paul H
2012-10-01
The length-tension (L-T) relationships in rabbit detrusor smooth muscle (DSM) are similar to those in vascular and airway smooth muscles and exhibit short-term length adaptation characterized by L-T curves that shift along the length axis as a function of activation and strain history. In contrast to skeletal muscle, the length-active tension (L-T(a)) curve for rabbit DSM strips does not have a unique peak tension value with a single ascending and descending limb. Instead, DSM can exhibit multiple ascending and descending limbs, and repeated KCl-induced contractions at a particular muscle length on an ascending or descending limb display increasingly greater tension. In the present study, mouse bladder strips with and without urothelium exhibited KCl-induced and carbachol-induced length adaptation, and the pressure-volume relationship in mouse whole bladder displayed short-term volume adaptation. Finally, prostaglandin-E(2)-induced low-level rhythmic contraction produced length adaptation in rabbit DSM strips. A likely role of length adaptation during bladder filling is to prepare DSM cells to contract efficiently over a broad range of volumes. Mammalian bladders exhibit spontaneous rhythmic contraction (SRC) during the filling phase and SRC is elevated in humans with overactive bladder (OAB). The present data identify a potential physiological role for SRC in bladder adaptation and motivate the investigation of a potential link between short-term volume adaptation and OAB with impaired contractility.
Effect of Interaction on the Majorana Zero Modes in the Kitaev Chain at Half Filling
NASA Astrophysics Data System (ADS)
Li, Zhidan; Han, Qiang
2018-04-01
The one dimension interacting Kitaev chain at half filling is studied. The symmetry of the Hamiltonian is examined by dual transformations and various physical quantities as functions of the fermion-fermion interaction $U$ are calculated systematically using the density matrix renormalization group method. A special value of interaction $U_p$ is revealed in the topological region of the phase diagram. We show that at $U_p$ the ground states are strictly two-fold degenerate even though the chain length is finite and the zero-energy peak due to the Majorana zero modes is maximally enhanced and exactly localized at the end sites. $U_p$ may be attractive or repulsive depending on other system parameters. We also give a qualitative understanding of the effect of interaction under the self-consistent mean field framework.
NASA Astrophysics Data System (ADS)
Qi, Shengqi; Hou, Deyi; Luo, Jian
2017-09-01
This study presents a numerical model based on field data to simulate groundwater flow in both the aquifer and the well-bore for the low-flow sampling method and the well-volume sampling method. The numerical model was calibrated to match well with field drawdown, and calculated flow regime in the well was used to predict the variation of dissolved oxygen (DO) concentration during the purging period. The model was then used to analyze sampling representativeness and sampling time. Site characteristics, such as aquifer hydraulic conductivity, and sampling choices, such as purging rate and screen length, were found to be significant determinants of sampling representativeness and required sampling time. Results demonstrated that: (1) DO was the most useful water quality indicator in ensuring groundwater sampling representativeness in comparison with turbidity, pH, specific conductance, oxidation reduction potential (ORP) and temperature; (2) it is not necessary to maintain a drawdown of less than 0.1 m when conducting low flow purging. However, a high purging rate in a low permeability aquifer may result in a dramatic decrease in sampling representativeness after an initial peak; (3) the presence of a short screen length may result in greater drawdown and a longer sampling time for low-flow purging. Overall, the present study suggests that this new numerical model is suitable for describing groundwater flow during the sampling process, and can be used to optimize sampling strategies under various hydrogeological conditions.
Jo, Insun; Pettes, Michael; Lindsay, Lucas R.; ...
2015-05-18
Thermal transport in suspended graphene samples has been measured in prior works and this work with the use of a suspended electro-thermal micro-bridge method. These measurement results are analyzed here to evaluate and eliminate the errors caused by the extrinsic thermal contact resistance. It is noted that the thermal resistance measured in a recent work increases linearly with the suspended length of the single-layer graphene samples synthesized by chemical vapor deposition (CVD), and that such a feature does not reveal the failure of Fourier s law despite the increase in the apparent thermal conductivity with length. The re-analyzed thermal conductivitymore » of a single-layer CVD graphene sample reaches about ( 1680 180 )Wm-1K-1 at room temperature, which is close to the highest value reported for highly oriented pyrolytic graphite. In comparison, the thermal conductivity values measured for two suspended exfoliated bi-layer graphene samples are about ( 880 60 ) and ( 730 60 ) Wm-1K-1 at room temperature, and approach that of the natural graphite source above room temperature. However, the low-temperature thermal conductivities of these suspended graphene samples are still considerably lower than the graphite values, with the peak thermal conductivities shifted to much higher temperatures. Analysis of the thermal conductivity data reveals that the low temperature behavior is dominated by phonon scattering by polymer residue instead of by the lateral boundary.« less
Variational Integration for Ideal Magnetohydrodynamics and Formation of Current Singularities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhou, Yao
Coronal heating has been a long-standing conundrum in solar physics. Parker's conjecture that spontaneous current singularities lead to nanoflares that heat the corona has been controversial. In ideal magnetohydrodynamics (MHD), can genuine current singularities emerge from a smooth 3D line-tied magnetic field? To numerically resolve this issue, the schemes employed must preserve magnetic topology exactly to avoid artificial reconnection in the presence of (nearly) singular current densities. Structure-preserving numerical methods are favorable for mitigating numerical dissipation, and variational integration is a powerful machinery for deriving them. However, successful applications of variational integration to ideal MHD have been scarce. In thismore » thesis, we develop variational integrators for ideal MHD in Lagrangian labeling by discretizing Newcomb's Lagrangian on a moving mesh using discretized exterior calculus. With the built-in frozen-in equation, the schemes are free of artificial reconnection, hence optimal for studying current singularity formation. Using this method, we first study a fundamental prototype problem in 2D, the Hahm-Kulsrud-Taylor (HKT) problem. It considers the effect of boundary perturbations on a 2D plasma magnetized by a sheared field, and its linear solution is singular. We find that with increasing resolution, the nonlinear solution converges to one with a current singularity. The same signature of current singularity is also identified in other 2D cases with more complex magnetic topologies, such as the coalescence instability of magnetic islands. We then extend the HKT problem to 3D line-tied geometry, which models the solar corona by anchoring the field lines in the boundaries. The effect of such geometry is crucial in the controversy over Parker's conjecture. The linear solution, which is singular in 2D, is found to be smooth. However, with finite amplitude, it can become pathological above a critical system length. The nonlinear solution turns out smooth for short systems. Nonetheless, the scaling of peak current density vs. system length suggests that the nonlinear solution may become singular at a finite length. With the results in hand, we cannot confirm or rule out this possibility conclusively, since we cannot obtain solutions with system lengths near the extrapolated critical value.« less
SU-F-I-34: How Does Longitudinal Dose Profile Change with Tube Current Distribution in CT?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, X; Yang, K; Liu, B
Purpose: To investigate how longitudinal dose profile D{sub L}(z) in 30 cm-diameter water cylinder change with tube current (mA) distribution and scan length. Methods: A constant and four variable mA distributions from two previous papers [Dixon et al., Med. Phys. 40, 111920 (14pp.) (2013); Zhang et al., Med. Phys. 41, 091911 (9pp.) (2014)] were adopted in three scan lengths of 10, 28.6, and 50 cm, and all mA distributions had the same average mA over scan ranges. Using the symmetry based dose calculation algorithms and the previously published CT dose equilibration data [Li et al., Med. Phys. 40, 031903 (10pp.)more » (2013); 41, 111910 (5pp.) (2014)], the authors calculated DL(z) on the phantom central and peripheral axes. Kolmogorov-Smirnov (K-S) test was used to compare the lineshapes of two arbitrary distributions. Results: In constant mA scans, D{sub L}(z) was “bell-shaped”. In variable mA scans, D{sub L}(z) approximately followed the mA lineshape, and the K-S distance generally changed with mA distribution. The distance decreased with scan length, and was larger on the central axis than on the peripheral axis. However, the opposite trends were found in the K-S distance between the D{sub L}(z) distributions of constant and variable mA distributions. Conclusion: Radiation dose from TCM scan is best evaluated using the specific tube current distribution. A constant mA based evaluation may lead to inconsistent longitudinal dose profile with that of TCM scan. Their difference in lineshape is larger on the phantom peripheral axis than on the central axis and increases with scan length. This work confirms that radiation dose in CT depends on not only local mA but also the overall mA distribution and scan length. On the other hand, the concept of regional tube current may be useful when scan length is large, tube current peaks near scan range edge, or the target site is superficial.« less
Method for compression of data using single pass LZSS and run-length encoding
Berlin, G.J.
1997-12-23
A method used preferably with LZSS-based compression methods for compressing a stream of digital data is disclosed. The method uses a run-length encoding scheme especially suited for data strings of identical data bytes having large run-lengths, such as data representing scanned images. The method reads an input data stream to determine the length of the data strings. Longer data strings are then encoded in one of two ways depending on the length of the string. For data strings having run-lengths less than 18 bytes, a cleared offset and the actual run-length are written to an output buffer and then a run byte is written to the output buffer. For data strings of 18 bytes or longer, a set offset and an encoded run-length are written to the output buffer and then a run byte is written to the output buffer. The encoded run-length is written in two parts obtained by dividing the run length by a factor of 255. The first of two parts of the encoded run-length is the quotient; the second part is the remainder. Data bytes that are not part of data strings of sufficient length are written directly to the output buffer. 3 figs.
Contractile properties of rat, rhesus monkey, and human type I muscle fibers
NASA Technical Reports Server (NTRS)
Widrick, J. J.; Romatowski, J. G.; Karhanek, M.; Fitts, R. H.
1997-01-01
It is well known that skeletal muscle intrinsic maximal shortening velocity is inversely related to species body mass. However, there is uncertainty regarding the relationship between the contractile properties of muscle fibers obtained from commonly studied laboratory animals and those obtained from humans. In this study we determined the contractile properties of single chemically skinned fibers prepared from rat, rhesus monkey, and human soleus and gastrocnemius muscle samples under identical experimental conditions. All fibers used for analysis expressed type I myosin heavy chain as determined by sodium dodecyl sulfate-polyacrylamide gel electrophoresis. Allometric coefficients for type I fibers from each muscle indicated that there was little change in peak tension (force/fiber cross-sectional area) across species. In contrast, both soleus and gastrocnemius type I fiber maximal unloaded shortening velocity (Vo), the y-intercept of the force-velocity relationship (Vmax), peak power per unit fiber length, and peak power normalized for fiber length and cross-sectional area were all inversely related to species body mass. The present allometric coefficients for soleus fiber Vo (-0.18) and Vmax (-0.11) are in good agreement with published values for soleus fibers obtained from common laboratory and domesticated mammals. Taken together, these observations suggest that the Vo of slow fibers from quadrupeds and humans scale similarly and can be described by the same quantitative relationships. These findings have implications in the design and interpretation of experiments, especially those that use small laboratory mammals as a model of human muscle function.
NASA Astrophysics Data System (ADS)
Momin, Md. Abdul; Kondo, Naoshi; Kuramoto, Makoto; Ogawa, Yuichi; Shigi, Tomoo
2011-06-01
Research was conducted to acquire knowledge of the ultraviolet and visible spectrums from 300 -800 nm of some common varieties of Japanese citrus, to investigate the best wave-lengths for fluorescence excitation and the resulting fluorescence wave-lengths and to provide a scientific background for the best quality fluorescent imaging technique for detecting surface defects of citrus. A Hitachi U-4000 PC-based microprocessor controlled spectrophotometer was used to measure the absorption spectrum and a Hitachi F-4500 spectrophotometer was used for the fluorescence and excitation spectrums. We analyzed the spectrums and the selected varieties of citrus were categorized into four groups of known fluorescence level, namely strong, medium, weak and no fluorescence.The level of fluorescence of each variety was also examined by using machine vision system. We found that around 340-380 nm LEDs or UV lamps are appropriate as lighting devices for acquiring the best quality fluorescent image of the citrus varieties to examine their fluorescence intensity. Therefore an image acquisition device was constructed with three different lighting panels with UV LED at peak 365 nm, Blacklight blue lamps (BLB) peak at 350 nm and UV-B lamps at peak 306 nm. The results from fluorescent images also revealed that the findings of the measured spectrums worked properly and can be used for practical applications such as for detecting rotten, injured or damaged parts of a wide variety of citrus.
NASA Astrophysics Data System (ADS)
Phillips, R. C.; Samadi, S. Z.; Meadows, M. E.
2018-07-01
This paper examines the frequency, distribution tails, and peak-over-threshold (POT) of extreme floods through analysis that centers on the October 2015 flooding in North Carolina (NC) and South Carolina (SC), United States (US). The most striking features of the October 2015 flooding were a short time to peak (Tp) and a multi-hour continuous flood peak which caused intensive and widespread damages to human lives, properties, and infrastructure. The 2015 flooding was produced by a sequence of intense rainfall events which originated from category 4 hurricane Joaquin over a period of four days. Here, the probability distribution and distribution parameters (i.e., location, scale, and shape) of floods were investigated by comparing the upper part of empirical distributions of the annual maximum flood (AMF) and POT with light- to heavy- theoretical tails: Fréchet, Pareto, Gumbel, Weibull, Beta, and Exponential. Specifically, four sets of U.S. Geological Survey (USGS) gauging data from the central Carolinas with record lengths from approximately 65-125 years were used. Analysis suggests that heavier-tailed distributions are in better agreement with the POT and somewhat AMF data than more often used exponential (light) tailed probability distributions. Further, the threshold selection and record length affect the heaviness of the tail and fluctuations of the parent distributions. The shape parameter and its evolution in the period of record play a critical and poorly understood role in determining the scaling of flood response to intense rainfall.
Albrecht, Jennifer Coyne; Kerby, Matthew B.; Niedringhaus, Thomas P.; Lin, Jennifer S.; Wang, Xiaoxiao; Barron, Annelise E.
2012-01-01
Here, we demonstrate the potential for high-resolution electrophoretic separations of ssDNA-protein conjugates in borosilicate glass microfluidic chips, with no sieving media and excellent repeatability. Using polynucleotides of two different lengths conjugated to moderately cationic protein polymer drag-tags, we measured separation efficiency as a function of applied electric field. In excellent agreement with prior theoretical predictions of Slater et al., resolution is found to remain constant as applied field is increased up to 700 V/cm, the highest field we were able to apply. This remarkable result illustrates the fundamentally different physical limitations of Free-Solution Conjugate Electrophoresis (FSCE)-based DNA separations relative to matrix-based DNA electrophoresis. Single-stranded DNA separations in “gels” have always shown rapidly declining resolution as the field strength is increased; this is especially true for ssDNA > 400 bases in length. FSCE’s ability to decouple DNA peak resolution from applied electric field suggests the future possibility of ultra-rapid FSCE sequencing on chips. We investigated sources of peak broadening for FSCE separations on borosilicate glass microchips, using six different protein polymer drag-tags. For drag-tags with four or more positive charges, electrostatic and adsorptive interactions with pHEA-coated microchannel walls led to appreciable band-broadening, while much sharper peaks were seen for bioconjugates with nearly charge-neutral protein drag-tags. PMID:21500207
Altered mechanical properties of titin immunoglobulin domain 27 in the presence of calcium.
DuVall, Michael M; Gifford, Jessica L; Amrein, Matthias; Herzog, Walter
2013-04-01
Titin (connectin) based passive force regulation has been an important physiological mechanism to adjust to varying muscle stretch conditions. Upon stretch, titin behaves as a spring capable of modulating its elastic response in accordance with changes in muscle biochemistry. One such mechanism has been the calcium-dependent stiffening of titin domains that renders the spring inherently more resistant to stretch. This transient titin-calcium interaction may serve a protective function in muscle, which could preclude costly unfolding of select domains when muscles elongate to great lengths. To test this idea, fluorescence spectroscopy was performed revealing a change in the microenvironment of the investigated immunoglobulin domain 27 (I27) of titin with calcium. Additionally, an atomic force microscope was used to evaluate the calcium-dependent regulation of passive force by stretching eight linked titin I27 domains until they unfolded. When stretching in the presence of calcium, the I27 homopolymer chain became stabilized, displaying three novel properties: (1) higher stretching forces were needed to unfold the domains, (2) the stiffness, measured as a persistence length (PL), increased and (3) the peak-to-peak distance between adjacent I27 domains increased. Furthermore, a peak order dependence became apparent for both force and PL, reflecting the importance of characterizing the dynamic unfolding history of a polymer with this approach. Together, this novel titin Ig-calcium interaction may serve to stabilize the I27 domain permitting titin to tune passive force within stretched muscle in a calcium-dependent manner.
Annual distributions and variations of dust weather occurrence over the Tarim Basin, China
NASA Astrophysics Data System (ADS)
Zhao, Yong; Zhou, Yang; Wang, Minzhong; Huo, Wen; Huang, Anning; Yang, Xinhua; Yang, Fan
2018-04-01
The annual distribution and variations in dust weather occurrence (DWO) have been analyzed using monthly DWO data from 26 stations over the Tarim Basin during the period of 1961 to 2010. The results show that the DWO presents a significant decreasing trend for different parts of the Tarim Basin in recent decades. The monthly DWO has two peaks in the east and west. In the first half of the year, the peak is in April, but in the second half of the year, the peak is in September. According to the concentration period and concentration degree (CD) of DWO, we can find that the maximum DWO occurs in April in the eastern, western, and northern parts of the basin, but it occurs in May in the southern part. The dust weather season is shorter for the northern and eastern parts of the basin than those of the remaining parts. On average, the dust weather season initiates in April in the northeast and in May for the rest of the region. As an indicator for the length of dust weather season, the CD is significantly related to DWO, with a correlation coefficient of -0.51, revealing an interesting feature of regional climate change with declining DWO and declining dust weather season over the Tarim Basin. The correlation analysis exhibits that all the Arctic Oscillation, Antarctic Oscillation, and North Atlantic Oscillation have a negative relation with the DWO but a positive relation with the length of dust weather season.
Adaptive Fourier decomposition based R-peak detection for noisy ECG Signals.
Ze Wang; Chi Man Wong; Feng Wan
2017-07-01
An adaptive Fourier decomposition (AFD) based R-peak detection method is proposed for noisy ECG signals. Although lots of QRS detection methods have been proposed in literature, most detection methods require high signal quality. The proposed method extracts the R waves from the energy domain using the AFD and determines the R-peak locations based on the key decomposition parameters, achieving the denoising and the R-peak detection at the same time. Validated by clinical ECG signals in the MIT-BIH Arrhythmia Database, the proposed method shows better performance than the Pan-Tompkin (PT) algorithm in both situations of a native PT and the PT with a denoising process.
A hetero-homogeneous investigation of chemical bath deposited Ga-doped ZnO nanorods
NASA Astrophysics Data System (ADS)
Rakhsha, Amir Hosein; Abdizadeh, Hossein; Pourshaban, Erfan; Golobostanfard, Mohammad Reza
2018-01-01
One-dimensional nanostructures of zinc oxide (ZnO) have been in the center of attention, mostly for electronic applications due to their distinctive properties such as high electron mobility (100 cm2V-1s-1) and crystallinity. Thanks to its high density of vacancies and interstitial sites, wurtzite lattice of ZnO is a suitable host for gallium (Ga) as a dopant element. Herein, ZnO nanorod arrays (NRAs) are synthesized by a low-temperature chemical bath deposition (CBD) method with various concentrations of gallium nitrate hydrate as a dopant precursor. Structural and morphological analyses confirm that optimum properties of gallium-doped ZnO (GZO) are obtained at 1% (Ga to Zn molar ratio). Owing to the replacement of smaller Ga3+ ions with Zn2+ ions in the GZO structure, a slight shift of (002) peak to higher angles could be observed in XRD pattern of GZO NRAs. The scanning electron microscope images demonstrate a proliferation in the ZnO NRAs length from 650 nm for undoped ZnO (UZO) to 1200 nm for GZO-1%. However, increasing the dopant concentration above 2.5% results in formation of homogeneous zinc gallium oxide in the bulk solution, which is a sign of inefficient process of doping in GZO NRAs. Furthermore, photoluminescence spectroscopy is used to characterize the band-gap variation of the samples, which demonstrates a small red-shift in the UV emission peak and a decrease in visible emission peak intensity with introducing Ga in ZnO lattice. Lower resistivity for GZO-1% (1.1 MΩ) sample compared to UZO (1.4 MΩ) is recorded, which is compelling evidence for the presence of Ga3+ in ZnO lattice. The results suggest that incorporating Ga into ZnO lattice using CBD method is an easy and effective technique to improve the electrical properties of ZnO NRAs that is an essential factor for a broad range of devices.
Sando, Steven K.; Sando, Roy; McCarthy, Peter M.; Dutton, DeAnn M.
2016-04-05
The climatic conditions of the specific time period during which peak-flow data were collected at a given streamflow-gaging station (hereinafter referred to as gaging station) can substantially affect how well the peak-flow frequency (hereinafter referred to as frequency) results represent long-term hydrologic conditions. Differences in the timing of the periods of record can result in substantial inconsistencies in frequency estimates for hydrologically similar gaging stations. Potential for inconsistency increases with decreasing peak-flow record length. The representativeness of the frequency estimates for a short-term gaging station can be adjusted by various methods including weighting the at-site results in association with frequency estimates from regional regression equations (RREs) by using the Weighted Independent Estimates (WIE) program. Also, for gaging stations that cannot be adjusted by using the WIE program because of regulation or drainage areas too large for application of RREs, frequency estimates might be improved by using record extension procedures, including a mixed-station analysis using the maintenance of variance type I (MOVE.1) procedure. The U.S. Geological Survey, in cooperation with the Montana Department of Transportation and the Montana Department of Natural Resources and Conservation, completed a study to provide adjusted frequency estimates for selected gaging stations through water year 2011.The purpose of Chapter D of this Scientific Investigations Report is to present adjusted frequency estimates for 504 selected streamflow-gaging stations in or near Montana based on data through water year 2011. Estimates of peak-flow magnitudes for the 66.7-, 50-, 42.9-, 20-, 10-, 4-, 2-, 1-, 0.5-, and 0.2-percent annual exceedance probabilities are reported. These annual exceedance probabilities correspond to the 1.5-, 2-, 2.33-, 5-, 10-, 25-, 50-, 100-, 200-, and 500-year recurrence intervals, respectively.The at-site frequency estimates were adjusted by weighting with frequency estimates from RREs using the WIE program for 438 selected gaging stations in Montana. These 438 selected gaging stations (1) had periods of record less than or equal to 40 years, (2) represented unregulated or minor regulation conditions, and (3) had drainage areas less than about 2,750 square miles.The weighted-average frequency estimates obtained by weighting with RREs generally are considered to provide improved frequency estimates. In some cases, there are substantial differences among the at-site frequency estimates, the regression-equation frequency estimates, and the weighted-average frequency estimates. In these cases, thoughtful consideration should be applied when selecting the appropriate frequency estimate. Some factors that might be considered when selecting the appropriate frequency estimate include (1) whether the specific gaging station has peak-flow characteristics that distinguish it from most other gaging stations used in developing the RREs for the hydrologic region; and (2) the length of the peak-flow record and the general climatic characteristics during the period when the peak-flow data were collected. For critical structure-design applications, a conservative approach would be to select the higher of the at-site frequency estimate and the weighted-average frequency estimate.The mixed-station MOVE.1 procedure generally was applied in cases where three or more gaging stations were located on the same large river and some of the gaging stations could not be adjusted using the weighted-average method because of regulation or drainage areas too large for application of RREs. The mixed-station MOVE.1 procedure was applied to 66 selected gaging stations on 19 large rivers.The general approach for using mixed-station record extension procedures to adjust at-site frequencies involved (1) determining appropriate base periods for the gaging stations on the large rivers, (2) synthesizing peak-flow data for the gaging stations with incomplete peak-flow records during the base periods by using the mixed-station MOVE.1 procedure, and (3) conducting frequency analysis on the combined recorded and synthesized peak-flow data for each gaging station. Frequency estimates for the combined recorded and synthesized datasets for 66 gaging stations with incomplete peak-flow records during the base periods are presented. The uncertainties in the mixed-station record extension results are difficult to directly quantify; thus, it is important to understand the intended use of the estimated frequencies based on analysis of the combined recorded and synthesized datasets. The estimated frequencies are considered general estimates of frequency relations among gaging stations on the same stream channel that might be expected if the gaging stations had been gaged during the same long-term base period. However, because the mixed-station record extension procedures involve secondary statistical analysis with accompanying errors, the uncertainty of the frequency estimates is larger than would be obtained by collecting systematic records for the same number of years in the base period.
NASA Astrophysics Data System (ADS)
Degrassie, J. S.
1990-12-01
The Soliton Microwave Generator (SMG) represents a truly new concept in the field of high power microwave (HPM) generation. A nonlinear, dispersive transmission line is used to convert an input voltage pulse into an HPM burst at the output. The system is all solid state and projects to be efficient and reliable. Single module peak powers in excess of 1 GW appear feasible, while combining modular units leads to a 10 GW system projection. This project for the DOE has allowed the first steps necessary in experimentally demonstrating the SMG. The project has ended successfully. A relatively high power lumped circuit SMG operating in the uhf band was designed, fabricated, and tested. The maximum peak output RF power was 16 MW from this line approx. 90 cm in length and 2 sq cm in cross section with a peak power efficiency of roughly 20 percent. Additionally a low power continuous strip-line approach demonstrated microwave generation well into L band, at approx. 2 GHz.
Emission of positronium in a nanometric PMMA film
NASA Astrophysics Data System (ADS)
Palacio, C. A.; De Baerdemaeker, J.; Van Thourhout, D.; Dauwe, C.
2008-10-01
Positron beam experiments have been performed for the first time on a self-supporting polymethyl metacrylate (PMMA) film of 310 nm-thick made by spin coating. The positronium (Ps) emission from the PMMA surface is studied as a function of the positron implantation energy by using Doppler profile spectroscopy and Compton-to-peak ratio analysis. When the sample and the Ge-detector are perpendicular to the positron beam, the emission of para-positronium ( p-Ps) is detected as a narrow central peak. By rotating the sample 45° with respect to the beam, the emission of p-Ps is detected as a blue-shifted fly-away peak. The bulk Ps fraction, the efficiency for the emission of Ps by picking up an electron from the surface, and the diffusion lengths of positrons (thermal and or epithermal), p-Ps and ortho-positronium ( o-Ps) are obtained.
Investigating the Feedback Path in a Jet-Surface Resonant Interaction
NASA Technical Reports Server (NTRS)
Zaman, Khairul; Fagan, Amy; Bridges, James; Brown, Cliff
2015-01-01
A resonant interaction between an 8:1 aspect ratio rectangular jet and flat-plates, placed parallel to the jet, is addressed in this study. For certain relative locations of the plates, the resonance takes place with accompanying audible tones. Even when the tone is not audible the sound pressure level spectra is often marked by conspicuous peaks. The frequencies of the spectral peaks, as functions of the streamwise length of the plate and its relative location to the jet as well as the jet Mach number, are explored in an effort of understand the flow mechanism. It is demonstrated that the tones are not due to a simple feedback between the plates trailing edge and the nozzle exit; the leading edge also comes into play in determining the frequency. An acoustic feedback path, involving diffraction from the leading edge, appears to explain the frequencies of some of the spectral peaks.
SUSANS With Polarized Neutrons.
Wagh, Apoorva G; Rakhecha, Veer Chand; Strobl, Makus; Treimer, Wolfgang
2005-01-01
Super Ultra-Small Angle Neutron Scattering (SUSANS) studies over wave vector transfers of 10(-4) nm(-1) to 10(-3) nm(-1) afford information on micrometer-size agglomerates in samples. Using a right-angled magnetic air prism, we have achieved a separation of ≈10 arcsec between ≈2 arcsec wide up- and down-spin peaks of 0.54 nm neutrons. The SUSANS instrument has thus been equipped with the polarized neutron option. The samples are placed in a uniform vertical field of 8.8 × 10(4) A/m (1.1 kOe). Several magnetic alloy ribbon samples broaden the up-spin neutron peak significantly over the ±1.3 × 10(-3) nm(-1) range, while leaving the down-spin peak essentially unaltered. Fourier transforms of these SUSANS spectra corrected for the instrument resolution, yield micrometer-range pair distribution functions for up- and down-spin neutrons as well as the nuclear and magnetic scattering length density distributions in the samples.
Relationship between cervical vertebral maturation and mandibular growth.
Ball, Gina; Woodside, Donald; Tompson, Bryan; Hunter, W Stuart; Posluns, James
2011-05-01
The cervical vertebrae have been proposed as a method of determining biologic maturity. The purposes of this study were to establish a pattern of mandibular growth and to relate this pattern to the stages of cervical vertebral maturation. Cephalometric radiographs, taken annually from ages 9 to 18 years, were evaluated for 90 boys from the Burlington Growth Center, Toronto, Ontario, Canada. Mandibular lengths were measured from articulare to gnathion, and incremental growth was determined. Cervical vertebral maturation stages were assessed by using a 6-stage method. Advanced, average, and delayed maturation groups were established. The prepubertal mandibular growth minimum velocity occurred during cervical stages 1 through 4 (P = 0.7327). Peak mandibular growth velocity occurred most frequently during stage 4 in all 3 maturation groups, with a statistical difference in the average and delayed groups (P <0.0001) and the advanced group (P = 0.0143). The average number of years spent in stage 4 was 3.79 (P <0.0001). The average amount of mandibular growth occurring during stage 4 was 9.40 mm (P <0.0001). The average amount of growth in stages 5 and 6 combined was 7.09 mm. Progression from cervical stages 1 through 6 does not occur annually; time spent in each stage varies depending on the stage and the maturation group. Cervical vertebral maturation stages cannot accurately identify the mandibular prepubertal growth minimum and therefore cannot predict the onset of the peak in mandibular growth. The cervical vertebral maturation stages should be used with other methods of biologic maturity assessment when considering both dentofacial orthopedic treatment and orthognathic surgery. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
1981-07-01
Crossman, 1973) or because water temperatures are more favorable ( Crawshaw , 1975). Peaks in the length frequency distribution of brown bullhead at 50...269. Crawshaw , L. I. 1975. Attainment of final thermal preferendum in brown bullheads acclimated to different temperatures. Comp. Biochem. Physiol
Energy Resiliency for Marine Corps Logistics Base Production Plant Barstow
2014-12-01
13 1. Biomass, Landfill Gas, and Biogas ...value in dollar per kilowatts ($/kW) peak of an outage cost obtained from the CDF curve for a specified duration of the interruption” (Giraldez, Booth...length of outages for inclusion in the VEES calculation, we needed to obtain power interruption and circuit reliability data from PPB’s utility
Conservation implications of spur length variation in long-spur columbines (Aquilegia longissima)
Christopher J. Stubben; Brook G. Milligan
2007-01-01
Populations of long-spur columbine (Aquilegia longissima) with spurs 10-16 cm long are known only from a few populations in Texas, a historical collection near Baboquivari Peak, Arizona, and scattered populations in Coahuila, Chihuahua, and Nuevo Leon, Mexico. Populations of yellow columbine with spurs 7-10 cm long are also found in Arizona, Texas,...
The role of alpine rockfall aquifer systems in baseflow maintenance and flood attenuation
NASA Astrophysics Data System (ADS)
Lauber, Ute; Kotyla, Patrick; Morche, David; Goldscheider, Nico
2015-04-01
Rockfall masses are frequent in alpine valleys. Huge rockfalls (millions to billions m³) precipitated after the end of the last glaciation, but many large events (thousand to millions m³) have occurred in historical time, and increasingly during the past decades, as a result of glacier retreat and thawing of permafrost. Most hydrological research focuses on water as a cause or trigger of rockfalls, while much less research has been done on the hydrogeological properties and functions of rockfall masses in alpine valleys. We have studied a series of rockfall and alluvial aquifer systems in the Reintal valley, German Alps, where all surface water infiltrates underground and reemerges downgradient from the rockfall masses. The goal of the study was to characterize the role of this rockfall aquifer in baseflow maintenance and flood attenuation. Employed methods include geomorphological and hydrogeological mapping, tracer tests, and continuous flow measurements. Field observations have revealed that both the infiltration and exfiltration locations vary as a function of the hydrologic conditions. Underground flow path length range from 500 m during high flows to 2 km during low flows; measured groundwater flow velocities range between 13 and 30 m/h; lag times between upstream and downstream flood peaks are 5 to 101 hours. Flood peaks were dampened by a factor of 1.5 and the maximum discharge ratio (22) and peak recession coefficient (0.2/d) downstream are very low compared with other alpine catchments. These results indicate that rockfall aquifers can play an important role in the flow regime and flood attenuation in alpine regions.
Effects of Step Rate Manipulation on Joint Mechanics during Running
Heiderscheit, Bryan C.; Chumanov, Elizabeth S.; Michalski, Max P.; Wille, Christa M.; Ryan, Michael B.
2010-01-01
Purpose The objective of this study was to characterize the biomechanical effects of step rate modification during running on the hip, knee and ankle joints, so as to evaluate a potential strategy to reduce lower extremity loading and risk for injury. Methods Three-dimensional kinematics and kinetics were recorded from 45 healthy recreational runners during treadmill running at constant speed under various step rate conditions (preferred, ± 5% and ± 10%). We tested our primary hypothesis that a reduction in energy absorption by the lower extremity joints during the loading response would occur, primarily at the knee, when step rate was increased. Results Less mechanical energy was absorbed at the knee (p<0.01) during the +5% and +10% step rate conditions, while the hip (p<0.01) absorbed less energy during the +10% condition only. All joints displayed substantially (p<0.01) more energy absorption when preferred step rate was reduced by 10. Step length (p<0.01), center of mass vertical excursion (p<0.01), breaking impulse (p<0.01) and peak knee flexion angle (p<0.01) were observed to decrease with increasing step rate. When step rate was increased 10% above preferred, peak hip adduction angle (p<0.01), as well as peak hip adduction (p<0.01) and internal rotation (p<0.01) moments, were found to decrease. Conclusion We conclude that subtle increases in step rate can substantially reduce the loading to the hip and knee joints during running and may prove beneficial in the prevention and treatment of common running-related injuries. PMID:20581720
A modular computational framework for automated peak extraction from ion mobility spectra
2014-01-01
Background An ion mobility (IM) spectrometer coupled with a multi-capillary column (MCC) measures volatile organic compounds (VOCs) in the air or in exhaled breath. This technique is utilized in several biotechnological and medical applications. Each peak in an MCC/IM measurement represents a certain compound, which may be known or unknown. For clustering and classification of measurements, the raw data matrix must be reduced to a set of peaks. Each peak is described by its coordinates (retention time in the MCC and reduced inverse ion mobility) and shape (signal intensity, further shape parameters). This fundamental step is referred to as peak extraction. It is the basis for identifying discriminating peaks, and hence putative biomarkers, between two classes of measurements, such as a healthy control group and a group of patients with a confirmed disease. Current state-of-the-art peak extraction methods require human interaction, such as hand-picking approximate peak locations, assisted by a visualization of the data matrix. In a high-throughput context, however, it is preferable to have robust methods for fully automated peak extraction. Results We introduce PEAX, a modular framework for automated peak extraction. The framework consists of several steps in a pipeline architecture. Each step performs a specific sub-task and can be instantiated by different methods implemented as modules. We provide open-source software for the framework and several modules for each step. Additionally, an interface that allows easy extension by a new module is provided. Combining the modules in all reasonable ways leads to a large number of peak extraction methods. We evaluate all combinations using intrinsic error measures and by comparing the resulting peak sets with an expert-picked one. Conclusions Our software PEAX is able to automatically extract peaks from MCC/IM measurements within a few seconds. The automatically obtained results keep up with the results provided by current state-of-the-art peak extraction methods. This opens a high-throughput context for the MCC/IM application field. Our software is available at http://www.rahmannlab.de/research/ims. PMID:24450533
A modular computational framework for automated peak extraction from ion mobility spectra.
D'Addario, Marianna; Kopczynski, Dominik; Baumbach, Jörg Ingo; Rahmann, Sven
2014-01-22
An ion mobility (IM) spectrometer coupled with a multi-capillary column (MCC) measures volatile organic compounds (VOCs) in the air or in exhaled breath. This technique is utilized in several biotechnological and medical applications. Each peak in an MCC/IM measurement represents a certain compound, which may be known or unknown. For clustering and classification of measurements, the raw data matrix must be reduced to a set of peaks. Each peak is described by its coordinates (retention time in the MCC and reduced inverse ion mobility) and shape (signal intensity, further shape parameters). This fundamental step is referred to as peak extraction. It is the basis for identifying discriminating peaks, and hence putative biomarkers, between two classes of measurements, such as a healthy control group and a group of patients with a confirmed disease. Current state-of-the-art peak extraction methods require human interaction, such as hand-picking approximate peak locations, assisted by a visualization of the data matrix. In a high-throughput context, however, it is preferable to have robust methods for fully automated peak extraction. We introduce PEAX, a modular framework for automated peak extraction. The framework consists of several steps in a pipeline architecture. Each step performs a specific sub-task and can be instantiated by different methods implemented as modules. We provide open-source software for the framework and several modules for each step. Additionally, an interface that allows easy extension by a new module is provided. Combining the modules in all reasonable ways leads to a large number of peak extraction methods. We evaluate all combinations using intrinsic error measures and by comparing the resulting peak sets with an expert-picked one. Our software PEAX is able to automatically extract peaks from MCC/IM measurements within a few seconds. The automatically obtained results keep up with the results provided by current state-of-the-art peak extraction methods. This opens a high-throughput context for the MCC/IM application field. Our software is available at http://www.rahmannlab.de/research/ims.
Kohn, Michael S.; Stevens, Michael R.; Harden, Tessa M.; Godaire, Jeanne E.; Klinger, Ralph E.; Mommandi, Amanullah
2016-09-09
The U.S. Geological Survey (USGS), in cooperation with the Colorado Department of Transportation, developed regional-regression equations for estimating the 50-, 20-, 10-, 4-, 2-, 1-, 0.5-, 0.2-percent annual exceedance-probability discharge (AEPD) for natural streamflow in eastern Colorado. A total of 188 streamgages, consisting of 6,536 years of record and a mean of approximately 35 years of record per streamgage, were used to develop the peak-streamflow regional-regression equations. The estimated AEPDs for each streamgage were computed using the USGS software program PeakFQ. The AEPDs were determined using systematic data through water year 2013. Based on previous studies conducted in Colorado and neighboring States and on the availability of data, 72 characteristics (57 basin and 15 climatic characteristics) were evaluated as candidate explanatory variables in the regression analysis. Paleoflood and non-exceedance bound ages were established based on reconnaissance-level methods. Multiple lines of evidence were used at each streamgage to arrive at a conclusion (age estimate) to add a higher degree of certainty to reconnaissance-level estimates. Paleoflood or nonexceedance bound evidence was documented at 41 streamgages, and 3 streamgages had previously collected paleoflood data.To determine the peak discharge of a paleoflood or non-exceedanc bound, two different hydraulic models were used.The mean standard error of prediction (SEP) for all 8 AEPDs was reduced approximately 25 percent compared to the previous flood-frequency study. For paleoflood data to be effective in reducing the SEP in eastern Colorado, a larger ratio than 44 of 188 (23 percent) streamgages would need paleoflood data and that paleoflood data would need to increase the record length by more than 25 years for the 1-percent AEPD. The greatest reduction in SEP for the peak-streamflow regional-regression equations was observed when additional new basin characteristics were included in the peak-streamflow regional-regression equations and when eastern Colorado was divided into two separate hydrologic regions. To make further reductions in the uncertainties of the peak-streamflow regional-regression equations in the Foothills and Plains hydrologic regions, additional streamgages or crest-stage gages are needed to collect peak-streamflow data on natural streams in eastern Colorado.Generalized-Least Squares regression was used to compute the final peak-streamflow regional-regression equations for peak-streamflow. Dividing eastern Colorado into two new individual regions at –104° longitude resulted in peak-streamflow regional-regression equations with the smallest SEP. The new hydrologic region located between –104° longitude and the Kansas-Nebraska State line will be designated the Plains hydrologic region and the hydrologic region comprising the rest of eastern Colorado located west of the –104° longitude and east of the Rocky Mountains and below 7,500 feet in the South Platte River Basin and below 9,000 feet in the Arkansas River Basin will be designated the Foothills hydrologic region.
Grall; Leonard; Sacks
2000-02-01
Recent advances in column heating technology have made possible very fast linear temperature programming for high-speed gas chromatography. A fused-silica capillary column is contained in a tubular metal jacket, which is resistively heated by a precision power supply. With very rapid column heating, the rate of peak-capacity production is significantly enhanced, but the total peak capacity and the boiling-point resolution (minimum boiling-point difference required for the separation of two nonpolar compounds on a nonpolar column) are reduced relative to more conventional heating rates used with convection-oven instruments. As temperature-programming rates increase, elution temperatures also increase with the result that retention may become insignificant prior to elution. This results in inefficient utilization of the down-stream end of the column and causes a loss in the rate of peak-capacity production. The rate of peak-capacity production is increased by the use of shorter columns and higher carrier gas velocities. With high programming rates (100-600 degrees C/min), column lengths of 6-12 m and average linear carrier gas velocities in the 100-150 cm/s range are satisfactory. In this study, the rate of peak-capacity production, the total peak capacity, and the boiling point resolution are determined for C10-C28 n-alkanes using 6-18 m long columns, 50-200 cm/s average carrier gas velocities, and 60-600 degrees C/min programming rates. It was found that with a 6-meter-long, 0.25-mm i.d. column programmed at a rate of 600 degrees C/min, a maximum peak-capacity production rate of 6.1 peaks/s was obtained. A total peak capacity of about 75 peaks was produced in a 37-s long separation spanning a boiling-point range from n-C10 (174 degrees C) to n-C28 (432 degrees C).
Method of multi-dimensional moment analysis for the characterization of signal peaks
Pfeifer, Kent B; Yelton, William G; Kerr, Dayle R; Bouchier, Francis A
2012-10-23
A method of multi-dimensional moment analysis for the characterization of signal peaks can be used to optimize the operation of an analytical system. With a two-dimensional Peclet analysis, the quality and signal fidelity of peaks in a two-dimensional experimental space can be analyzed and scored. This method is particularly useful in determining optimum operational parameters for an analytical system which requires the automated analysis of large numbers of analyte data peaks. For example, the method can be used to optimize analytical systems including an ion mobility spectrometer that uses a temperature stepped desorption technique for the detection of explosive mixtures.
Kessler, Erich W.; Lorenz, David L.; Sanocki, Christopher A.
2013-01-01
Peak-flow frequency analyses were completed for 409 streamgages in and bordering Minnesota having at least 10 systematic peak flows through water year 2011. Selected annual exceedance probabilities were determined by fitting a log-Pearson type III probability distribution to the recorded annual peak flows. A detailed explanation of the methods that were used to determine the annual exceedance probabilities, the historical period, acceptable low outliers, and analysis method for each streamgage are presented. The final results of the analyses are presented.
Yang, X X; Li, J W; Zhou, Z F; Wang, Y; Yang, L W; Zheng, W T; Sun, Chang Q
2012-01-21
From the perspective of bond relaxation and bond vibration, we have formulated the Raman phonon relaxation of graphene, under the stimuli of the number-of-layers, the uni-axial strain, the pressure, and the temperature, in terms of the response of the length and strength of the representative bond of the entire specimen to the applied stimuli. Theoretical unification of the measurements clarifies that: (i) the opposite trends of the Raman shifts, which are due to the number-of-layers reduction, of the G-peak shift and arises from the vibration of a pair of atoms, while the D- and the 2D-peak shifts involve the z-neighbor of a specific atom; (ii) the tensile strain-induced phonon softening and phonon-band splitting arise from the asymmetric response of the C(3v) bond geometry to the C(2v) uni-axial bond elongation; (iii) the thermal softening of the phonons originates from bond expansion and weakening; and (iv) the pressure stiffening of the phonons results from bond compression and work hardening. Reproduction of the measurements has led to quantitative information about the referential frequencies from which the Raman frequencies shift as well as the length, energy, force constant, Debye temperature, compressibility and elastic modulus of the C-C bond in graphene, which is of instrumental importance in the understanding of the unusual behavior of graphene.
Walking, running and the evolution of short toes in humans.
Rolian, Campbell; Lieberman, Daniel E; Hamill, Joseph; Scott, John W; Werbel, William
2009-03-01
The phalangeal portion of the forefoot is extremely short relative to body mass in humans. This derived pedal proportion is thought to have evolved in the context of committed bipedalism, but the benefits of shorter toes for walking and/or running have not been tested previously. Here, we propose a biomechanical model of toe function in bipedal locomotion that suggests that shorter pedal phalanges improve locomotor performance by decreasing digital flexor force production and mechanical work, which might ultimately reduce the metabolic cost of flexor force production during bipedal locomotion. We tested this model using kinematic, force and plantar pressure data collected from a human sample representing normal variation in toe length (N=25). The effect of toe length on peak digital flexor forces, impulses and work outputs was evaluated during barefoot walking and running using partial correlations and multiple regression analysis, controlling for the effects of body mass, whole-foot and phalangeal contact times and toe-out angle. Our results suggest that there is no significant increase in digital flexor output associated with longer toes in walking. In running, however, multiple regression analyses based on the sample suggest that increasing average relative toe length by as little as 20% doubles peak digital flexor impulses and mechanical work, probably also increasing the metabolic cost of generating these forces. The increased mechanical cost associated with long toes in running suggests that modern human forefoot proportions might have been selected for in the context of the evolution of endurance running.
NASA Astrophysics Data System (ADS)
Avilés Lucas, P.; Dance, D. R.; Castellano, I. A.; Vañó, E.
2004-04-01
A Monte Carlo computational model of CT has been developed and used to investigate the effect of various physical factors on the surface air kerma length product, the peak surface air kerma, the air kerma length product within a phantom and the energy imparted. The factors investigated were the bow-tie filter and the size, shape and position of a phantom which simulates the patient. The calculations show that the surface air kerma length product and the maximum surface air kerma are mainly dependent on phantom position and decrease along the vertical axis of the CT plane as the phantom surface moves away from the isocentre along this axis. As a result, measurements using standard body dosimetry phantoms may underestimate the skin dose for real patients. This result is specially important for CT fluoroscopic procedures: for an adult patient the peak skin dose can be 37% higher than that estimated with a standard measurement on the body AAPM (American Association of Physicists in Medicine) phantom. The results also show that the energy imparted to a phantom is mainly influenced by phantom size and is nearly independent of phantom position (within 3%) and shape (up to 5% variation). However, variations of up to 30% were found for the air kerma to regions within the AAPM body phantom when it is moved vertically. This highlights the importance of calculating doses to organs taking into account their size and position within the gantry.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deng, Liulin; Ibrahim, Yehia M.; Hamid, Ahmed M.
We report the development and initial evaluation of a 13-m path length Structures for Lossless Manipulations (SLIM) module for achieving high resolution separations using traveling waves (TW) with ion mobility (IM) spectrometry. The TW SLIM module was fabricated using two mirror-image printed circuit boards with appropriately configured RF, DC and TW electrodes and positioned with a 2.75-mm inter-surface gap. Ions were effective confined between the surfaces by RF-generated pseudopotential fields and moved losslessly through a serpentine path including 44 “U” turns using TWs. The ion mobility resolution was characterized at different pressures, gaps between the SLIM surfaces, TW and RFmore » parameters. After initial optimization the SLIM IM-MS module provided about 5-fold higher resolution separations than present commercially available drift tube or traveling wave IM-MS platforms. Peak capacity and peak generation rates achieved were 246 and 370 s-1, respectively, at a TW speed of 148 m/s. The high resolution achieved in the TW SLIM IM-MS enabled e.g., isomeric sugars (Lacto-N-fucopentaose I and Lacto-N-fucopentaose II) to be baseline resolved, and peptides from a albumin tryptic digest much better resolved than with existing commercial IM-MS platforms. The present work also provides a foundation for the development of much higher resolution SLIM devices based upon both considerably longer path lengths and multi-pass designs.« less
Li, Songhai; Wang, Ding; Wang, Kexiong; Hoffmann-Kuhnt, Matthias; Fernando, Nimal; Taylor, Elizabeth A; Lin, Wenzhi; Chen, Jialin; Ng, Timothy
2013-11-15
The hearing and echolocation clicks of a stranded Indo-Pacific humpback dolphin (Sousa chinensis) in Zhuhai, China, were studied. This animal had been repeatedly observed in the wild before it was stranded and its age was estimated to be ~40 years. The animal's hearing was measured using a non-invasive auditory evoked potential (AEP) method. Echolocation clicks produced by the dolphin were recorded when the animal was freely swimming in a 7.5 m (width)×22 m (length)×4.8 m (structural depth) pool with a water depth of ~2.5 m. The hearing and echolocation clicks of the studied dolphin were compared with those of a conspecific younger individual, ~13 years of age. The results suggested that the cut-off frequency of the high-frequency hearing of the studied dolphin was ~30-40 kHz lower than that of the younger individual. The peak and centre frequencies of the clicks produced by the older dolphin were ~16 kHz lower than those of the clicks produced by the younger animal. Considering that the older dolphin was ~40 years old, its lower high-frequency hearing range with lower click peak and centre frequencies could probably be explained by age-related hearing loss (presbycusis).
Clinical Characteristics, Management, and Outcomes of Suspected Poststroke Acute Coronary Syndrome
De Venecia, Toni Anne; Wongrakpanich, Supakanya; Rodriguez-Ziccardi, Mary; Yadlapati, Sujani; Kishlyansky, Marina; Rammohan, Harish Seetha; Figueredo, Vincent M.
2017-01-01
Background Acute coronary syndrome (ACS) can complicate acute ischemic stroke, causing significant morbidity and mortality. To date, literatures that describe poststroke acute coronary syndrome and its morbidity and mortality burden are lacking. Methods This is a single center, retrospective study where clinical characteristics, cardiac evaluation, and management of patients with suspected poststroke ACS were compared and analyzed for their association with inpatient mortality and 1-year all-cause mortality. Results Of the 82 patients, 32% had chest pain and 88% had ischemic ECG changes; mean peak troponin level was 18, and mean ejection fraction was 40%. The medical management group had older individuals (73 versus 67 years, p < 0.05), lower mean peak troponin levels (12 versus 49, p < 0.05), and lower mean length of stay (12 versus 25 days, p < 0.05) compared to those who underwent stent or CABG. Troponin levels were significantly associated with 1-year all-cause mortality. Conclusion Age and troponin level appear to play a role in the current clinical decision making for patient with suspected poststroke ACS. Troponin level appears to significantly correlate with 1-year all-cause mortality. In the management of poststroke acute coronary syndrome, optimal medical therapy had similar inpatient and all-cause mortality compared to PCI and/or CABG. PMID:29130017
Angular power spectrum in publically released ALICE events
NASA Astrophysics Data System (ADS)
Llanes-Estrada, Felipe J.; Muñoz Martinez, Jose L.
2018-02-01
We study the particles emitted in the fireball following a Relativistic Heavy Ion Collision with the traditional angular analysis employed in cosmology and earth sciences, producing Mollweide plots of the number and pt distribution of a few actual, publically released ALICE-collaboration events and calculating their angular power spectrum. We also examine the angular spectrum of a simple two-particle correlation. While this may not be the optimal way of analyzing heavy ion data, our intention is to provide a one to one comparison to analysis in cosmology. With the limited statistics at hand, we do not find evidence for acoustic peaks but a decrease of Cl that is reminiscent of viscous attenuation, but subject to a strong effect from the rapidity acceptance which probably dominates (so we also subtract the m = 0 component). As an exercise, we still extract a characteristic Silk damping length (proportional to the square root of the viscosity over entropy density ratio) to illustrate the method. The absence of acoustic-like peaks is also compatible with a crossover from the QGP to the hadron gas (because a surface tension at domain boundaries would effect a restoring force that could have driven acoustic oscillations). Presently we do not understand a depression of the l = 6 multipole strength; perhaps ALICE could reexamine it with full statistics.
Ground motion hazard from supershear rupture
Andrews, D.J.
2010-01-01
An idealized rupture, propagating smoothly near a terminal rupture velocity, radiates energy that is focused into a beam. For rupture velocity less than the S-wave speed, radiated energy is concentrated in a beam of intense fault-normal velocity near the projection of the rupture trace. Although confined to a narrow range of azimuths, this beam diverges and attenuates. For rupture velocity greater than the S-wave speed, radiated energy is concentrated in Mach waves forming a pair of beams propagating obliquely away from the fault. These beams do not attenuate until diffraction becomes effective at large distance. Events with supershear and sub-Rayleigh rupture velocity are compared in 2D plane-strain calculations with equal stress drop, fracture energy, and rupture length; only static friction is changed to determine the rupture velocity. Peak velocity in the sub-Rayleigh case near the termination of rupture is larger than peak velocity in the Mach wave in the supershear case. The occurrence of supershear rupture propagation reduces the most intense peak ground velocity near the fault, but it increases peak velocity within a beam at greater distances.