Steam sterilization effect on the accuracy of friction-style mechanical torque limiting devices.
Sadr, Seyed Jalil; Fayyaz, Ali; Mahshid, Minoo; Saboury, Aboulfazl; Ansari, Ghassem
2014-01-01
This study was aimed to evaluate the effect of steam sterilization on the accuracy (within 10%) of friction-style mechanical torque limiting devices (F-S MTLDs) to achieve their target torque values. Fifteen new F-S MTLDs were selected from Astra Tech (25 Ncm, Hader SA, La Chaux-de-Fonds, Switzerland), BioHorizons (30 Ncm, Dynatorq ITL, Irvine, California, USA), Dr. Idhe (15-60 Ncm, Dr. Idhe Dental, Eching/Munich, Germany). Every peak torque measurement was tested ten times before steam sterilization using Tohnichi torque gauge (6Tohnichi-BTG (-S), Japan). Steam sterilization was performed using a 100 cycle autoclave. Preparation steps were carried out for the devices before each autoclave sterilization cycle. Peak torque measurements were repeated after every sterilization cycle. Mean difference between the measured and the targeted torque values were evaluated before and after aging. Repeated-measures of ANOVA were used to compare the differences of accuracy between subjects. Bonferroni post-hoc test was used for pairwise comparison. Autoclaving resulted in an increase in the error values (the difference between peak torque and target torque values) in all the three groups studied (P < 0.05), with only Astra Tech devices showing >10% (maximum 12%) difference from their torque values in 5% of the measurements. Steam sterilization effect differs between target torque and measured peak values with an increase trend. The peak torque values showed a significant decrease for BioHorizons, while a significant increase was noted for Astra Tech and no significant change in Dr. Idhe group after sterilization. Within the limitation of this study the torque output of each individual device deviated in varying degrees from target torque values. However, the majority of the new frictional-style devices tested in this study, delivered fairly consistent torque output within 10% of their preset target values after sterilization. Astra Tech devices were the only one showing more than 10% difference from their torque values in 5% of the measurements. Combined effects of sterilization and aging still needs to be determined.
Eitzen, I; Eitzen, TJ; Holm, I; Snyder-Mackler, L; Risberg, MA
2011-01-01
Background Isokinetic muscle strength tests using the peak torque value is the most frequently included quadriceps muscle strength measurement for anterior cruciate ligament (ACL) injured subjects. Aims The purpose of this study was to investigate quadriceps muscle performance during the whole isokinetic curve in ACL deficient subjects classified as potential copers or non-copers, and investigate whether these curve profiles were associated with single-leg hop performance. We hypothesized that quadriceps muscle torque at other knee flexion angles than peak torque would give more information about quadriceps muscle strength deficits. Furthermore, we hypothesized that there would be significant torque differences between potential copers and non-copers, and a significant relationship between angle specific torque values and single-leg hop performance. Study Design Cross-sectional study; Level of evidence, 2 Methods Seventy-six individuals with a complete unilateral ACL rupture within the last 3 months were included. The subjects were classified into potential copers and non-copers according to the criteria from Fitzgerald et al12. Isokinetic quadriceps muscle tests were performed at 60°/sec (Biodex 6000). Mean torque values were calculated for peak torque as well as for specific knee flexion angles. The one-leg hop and the 6 meter timed hop tests were included and symmetry indices were used. Results The peak torque value did not identify the largest quadriceps muscle strength deficit. Rather, these were established at knee flexion angles of less than 40°. There were significant differences in angle specific torque values between potential copers and non-copers (p<0.05). Moderate to strong associations were disclosed between angle specific torque values and single-leg hop performance, but only for non-copers (r≥0.32– 0.58). Conclusions Angle specific quadriceps muscle torque values of less than 40° of knee flexion provide more information on the quadriceps strength deficits after ACL injury compared to the commonly used peak torque values. PMID:20110458
Saboury, Aboulfazl; Sadr, Seyed Jalil; Fayaz, Ali; Mahshid, Minoo
2013-01-01
Objective: High variability in delivering the target torque is reported for friction-style mechanical torque limiting devices (F-S MTLDs). The effect of aging (number of use) on the accuracy of these devices is not clear. The purpose of this study was to assess the effect of aging on the accuracy (±10% of the target torque) of F-S MTLDs. Materials and Methods: Fifteen new F-S MTLDs and their appropriate drivers from three different implant manufacturers (Astra Tech, Biohorizon and Dr Idhe), five for each type, were selected. The procedure of peak torque measurement was performed in ten sequences before and after aging. In each sequence, ten repetitions of peak torque values were registered for the aging procedure. To measure the output of each device, a Tohnichi torque gauge was used. Results: Before aging, peak torque measurements of all the devices tested in this study falled within 10% of their preset target values. After aging, a significant difference was seen between raw error values of three groups of MTLDs (P<0.05). More than 50% of all peak torque measurements demonstrated more than 10% difference from their torque values after aging. Conclusion: Within the limitation of this study, aging as an independent factor affects the accuracy of F-S MTLDs. Astra Tech MTLDs presented the most consistent torque output for 25 Ncm target torque. PMID:23724202
Whang, C Z Y; Bister, D; Sherriff, M
2011-12-01
This study compared peak insertion torque values of six commercially available self-drilling mini-implants [Mini Spider® screw (1.5 × 8 mm), Infinitas® (1.5 × 9 mm), Vector TAS® (1.4 × 8 mm), Dual Top® (1.6 × 8 mm), Tomas Pin® (1.6 × 8 mm), and Ortho-Easy® (1.7 × 6, 8, and 10 mm)]. Twenty implants each were drilled into acrylic rods at a speed of 8 rpm using a motorized torque measurement stand, and the values were recorded in Newton centimetres (Ncm). A further 20 Ortho-Easy® implants with a length of 6 and 10 mm were tested at 8 rpm; 20 implants of 6 mm length were also tested at 4 rpm. Kaplan-Meier estimates of the peak torque values were compared using the log-rank test with multiple comparisons evaluated by Sidak's test. There were significant differences in the maximum torque values for different mini-implants with the same length. The Mini Spider® screw and Infinitas® showed the lowest average torque values (6.5 and 12.4 Ncm) compared with Vector TAS®, Dual ToP®, Tomas Pin®, and Ortho-Easy® (30.9, 29.4, 25.4, and 24.8 Ncm, respectively). There was no correlation between the diameter of the implants and torque values. The Tomas Pin® showed the largest standard deviation (7.7 Ncm) and the Dual Top® implant the smallest (0.6 Ncm). Different insertion speeds did not result in significant differences in peak torque values but the 6 mm mini-implants showed significantly higher torque values than the 8 and 10 mm implants. Using a 'torque limiting' screwdriver or pre-drilling cortical bone to reduce insertion, torque appears justified for some of the tested implants.
Fayaz, Ali; Mahshid, Minoo; Saboury, Aboulfazl; Sadr, Seyed Jalil; Ansari, Ghassem
2014-01-01
Background: Mechanical torque limiting devices (MTLDs) are necessary tools to control a peak torque and achieving target values of screw component of dental implants. Due to probable effect of autoclaving and number of use on the accuracy of these devices, this study aimed to evaluate the effect of sterilization and number of use on the accuracy of friction-style mechanical torque limiting devices (F-S MTLDs) in achieving their target torque values. Materials and Methods: Peak torque measurements of 15 new F-S MTLDs from three different manufacturers (Astra Tech, BioHorizons, Dr. Idhe) were measured ten times before and after 100 steam sterilization using a digital torque gauge. To simulate the clinical situation of aging (number of use) target torque application process was repeated 10 times after each sterilization cycle and the peak torque values were registered. Comparison of the mean differences with target torque in each cycle was performed using one sample t test. Considering the type of MTLDs as inter subject comparison, One-way repeated measure ANOVA was used to evaluate the absolute values of differences between devices of each manufacturer in each group (α = 0.05). Results: The results of this study in Dr. Idhe group showed that, mean of difference values significantly differed from the target torque (P = 0.002) until 75 cycles. In Astra Tech group, also mean of difference values with under estimation trend, showed a significant difference with the target torque (P < 0.001). Mean of difference values significantly differed from the target torque with under estimation trend during all the 100 cycles in BioHorizons group (P < 0.05). Conclusion: The torque output of each individual device stayed in 10% difference from target torque values before 100 sterilization cycles, but more than 10% difference from the target torque was seen in varying degrees during these consequent cycles. PMID:24688564
Sugiura, Yoshito; Hatanaka, Yasuhiko; Arai, Tomoaki; Sakurai, Hiroaki; Kanada, Yoshikiyo
2016-04-01
We aimed to investigate whether a linear regression formula based on the relationship between joint torque and angular velocity measured using a high-speed video camera and image measurement software is effective for estimating 1 repetition maximum (1RM) and isometric peak torque in knee extension. Subjects comprised 20 healthy men (mean ± SD; age, 27.4 ± 4.9 years; height, 170.3 ± 4.4 cm; and body weight, 66.1 ± 10.9 kg). The exercise load ranged from 40% to 150% 1RM. Peak angular velocity (PAV) and peak torque were used to estimate 1RM and isometric peak torque. To elucidate the relationship between force and velocity in knee extension, the relationship between the relative proportion of 1RM (% 1RM) and PAV was examined using simple regression analysis. The concordance rate between the estimated value and actual measurement of 1RM and isometric peak torque was examined using intraclass correlation coefficients (ICCs). Reliability of the regression line of PAV and % 1RM was 0.95. The concordance rate between the actual measurement and estimated value of 1RM resulted in an ICC(2,1) of 0.93 and that of isometric peak torque had an ICC(2,1) of 0.87 and 0.86 for 6 and 3 levels of load, respectively. Our method for estimating 1RM was effective for decreasing the measurement time and reducing patients' burden. Additionally, isometric peak torque can be estimated using 3 levels of load, as we obtained the same results as those reported previously. We plan to expand the range of subjects and examine the generalizability of our results.
Mahshid, Minoo; Sadr, Seyed Jalil; Fayyaz, Ali; Kadkhodazadeh, Mahdi
2013-01-01
Purpose This study aimed to assess the combined effect of dismantling before sterilization and aging on the accuracy (±10% of the target torque) of spring-style mechanical torque devices (S-S MTDs). Methods Twenty new S-SMTDs from two different manufacturers (Nobel Biocare and Straumann: 10 of each type) were selected and divided into two groups, namely, case (group A) and control (group B). For sterilization, 100 cycles of autoclaving were performed in 100 sequences. In each sequence, 10 repetitions of peak torque values were registered for aging. To measure and assess the output of each device, a Tohnichi torque gauge was used (P<0.05). Results Before steam sterilization, all of the tested devices stayed within 10% of their target values. After 100 cycles of steam sterilization and aging with or without dismantling of the devices, the Nobel Biocare devices stayed within 10% of their target torque. In the Straumann devices, despite the significant difference between the peak torque and target torque values, the absolute error values stayed within 10% of their target torque. Conclusion Within the limitations of this study, there was no significant difference between the mean and absolute value of error between Nobel Biocare and Straumann S-S MTDs. PMID:24236244
Suhm, Norbert; Hengg, Clemens; Schwyn, Ronald; Windolf, Markus; Quarz, Volker; Hänni, Markus
2007-08-01
Bone strength plays an important role in implant anchorage. Bone mineral density (BMD) is used as surrogate parameter to quantify bone strength and to predict implant anchorage. BMD can be measured by means of quantitative computer tomography (QCT) or dual energy X-ray absorptiometry (DXA). These noninvasive methods for BMD measurement are not available pre- or intra-operatively. Instead, the surgeon could determine bone strength by direct mechanical measurement. We have evaluated mechanical torque measurement for (A) its capability to quantify local bone strength and (B) its predictive value towards load at implant cut-out. Our experimental study was performed using sixteen paired human cadaver proximal femurs. BMD was determined for all specimens by QCT. The torque to breakaway of the cancellous bone structure (peak torque) was measured by means of a mechanical probe at the exact position of subsequent DHS placement. The fixation strength of the DHS achieved was assessed by cyclic loading in a stepwise protocol beginning with 1,500 N increasing 500 N every 5,000 cycles until 4,000 N. A highly significant correlation of peak torque with BMD (QCT) was found (r = 0.902, r (2) = 0.814, P < 0.001). Peak torque correlated highly significant with the load at implant cut-out (r = 0.795, P < 0.001). All specimens with a measured peak torque below 6.79 Nm failed at the first load level of 1,500 N. The specimens with a peak torque above 8.63 Nm survived until the last load level of 4,000 N. Mechanical peak torque measurement is able to quantify bone strength. In an experimental setup, peak torque identifies those specimens that are likely to fail at low load. In clinical routine, implant migration and cut-out depend on several parameters, which are difficult to control, such as fracture type, fracture reduction achieved, and implant position. The predictive value of peak torque towards cut-out in a clinical set-up therefore has to be carefully validated.
Kazemi, Mahmood; Rohanian, Ahmad; Monzavi, Abbas; Nazari, Mohammad Sadegh
2013-01-01
Objective: Accurate delivery of torque to implant screws is critical to generate ideal preload in the screw joint and to offer protection against screw loosening. Mechanical torque-limiting devices (MTLDs) are available for this reason. In this study, the accuracy of one type of friction-style and two types of spring-style MTLDs at baseline, following fatigue conditions and sterilization processes were determined. Materials and Methods: Five unused MTLDs were selected from each of Straumann (ITI), Astra TECH and CWM systems. To measure the output of each MTLD, a digital torque gauge with a 3-jaw chuck was used to hold the driver. Force was applied to the MTLDs until either the friction styles released at a pre-calibrated torque value or the spring styles flexed to a pre-calibrated limit (target torque value). The peak torque value was recorded and the procedure was repeated 5 times for each MTLD. Then MTLDs were subjected to fatigue conditions at 500 and 1000 times and steam sterilization processes at 50 and 100 times and the peak torque value was recorded again at each stage. Results: Adjusted difference between measured torque values and target torque values differed significantly between stages for all 3 systems. Adjusted difference did not differ significantly between systems at all stages, but differed significantly between two different styles at baseline and 500 times fatigue stages. Conclusion: Straumann (ITI) devices differed minimally from target torque values at all stages. MTLDs with Spring-style were significantly more accurate than Friction-style device in achieving their target torque values at baseline and 500 times fatigue. PMID:23724209
Modelling dental implant extraction by pullout and torque procedures.
Rittel, D; Dorogoy, A; Shemtov-Yona, K
2017-07-01
Dental implants extraction, achieved either by applying torque or pullout force, is used to estimate the bone-implant interfacial strength. A detailed description of the mechanical and physical aspects of the extraction process in the literature is still missing. This paper presents 3D nonlinear dynamic finite element simulations of a commercial implant extraction process from the mandible bone. Emphasis is put on the typical load-displacement and torque-angle relationships for various types of cortical and trabecular bone strengths. The simulations also study of the influence of the osseointegration level on those relationships. This is done by simulating implant extraction right after insertion when interfacial frictional contact exists between the implant and bone, and long after insertion, assuming that the implant is fully bonded to the bone. The model does not include a separate representation and model of the interfacial layer for which available data is limited. The obtained relationships show that the higher the strength of the trabecular bone the higher the peak extraction force, while for application of torque, it is the cortical bone which might dictate the peak torque value. Information on the relative strength contrast of the cortical and trabecular components, as well as the progressive nature of the damage evolution, can be revealed from the obtained relations. It is shown that full osseointegration might multiply the peak and average load values by a factor 3-12 although the calculated work of extraction varies only by a factor of 1.5. From a quantitative point of view, it is suggested that, as an alternative to reporting peak load or torque values, an average value derived from the extraction work be used to better characterize the bone-implant interfacial strength. Copyright © 2017 Elsevier Ltd. All rights reserved.
Peak insertion torque values of five mini-implant systems under different insertion loads.
Quraishi, Erma; Sherriff, Martyn; Bister, Dirk
2014-06-01
To assess the effect of 1 and 3 kg insertion load on five makes of self-drilling mini-implants on peak insertion torque values to establish risk factors involved in the fracture of mini-implants. Two different loads were applied during insertion of 40 mini-implants from five different manufacturers (Dual Top(™) (1·6×8 mm), Infinitas(™) (1·5×9 mm), Ortho Easy(™) (1·7×8 mm), Spider Screw(™) (1·5×8 mm) and Vector TAS(™) (1·4×8 mm)) into acrylic blocks at 8 rev/min utilizing a Motorized Torque Measurement Stand. Peak insertion torque values for both loads were highest for Vector TAS followed by Ortho Easy and Dual Top and were nearly three times higher than Infinitas (original version) and Spider Screws(TM). The log-rank test showed statistically significant differences for both loads for Vector TAS, Ortho Easy and Spider Screws. Unlike other designs tested, both tapered mini-implant designs (Spider Screw and Infinitas) showed a tendency to buckle in the middle of the body but fractured at the tip. Non-tapered mini-implants fractured at significantly higher torque values compared to tapered designs under both loads. Increased pressure resulted in slightly higher maximum torque values at fracture for some of the mini-implant designs, although this is unlikely to be of clinical relevance. Tripling insertion pressure from 1 to 3 kg increased the risk of bending tapered mini-implants before fracture. © 2014 British Orthodontic Society.
Quantification of bone strength by intraoperative torque measurement: a technical note.
Suhm, Norbert; Haenni, Markus; Schwyn, Ronald; Hirschmann, Michael; Müller, Andreas Marc
2008-06-01
Bone strength describes the resistance of bone against mechanical failure. Bone strength depends on both the amount of bone and the bone's quality, and the bone strength may be looked upon as a relevant parameter to judge an osteosynthesis' stability. Information about bone strength was barely available intraoperatively in the past. The previous work of our group reported on development and laboratory evaluation of mechanical torque measurement as a method for the intraoperative quantification of bone strength. With the clinical series presented here we intend to verify that the im gesamten Text DensiProbe instrumentation for intraoperative torque measurement and the related measurement method are eligible for intraoperative use based on the following criteria: application of the method may not create complications, the measurement can be performed by the surgeon himself and may only cause a limited increase in the procedure time. From December 2006 until May 2007 ten patients with a pertrochanteric femoral fracture or a lateral femoral neck fracture eligible for stabilization with DHS were included in the study after having received informed consent. Any medication and comorbidity that might have influenced bone quality or bone mineral density (BMD) in these patients was documented. Bone strength was intraoperatively measured with DensiProbe. Complications that were obviously related with torque measurement were documented as well as any deviation from the suggested procedure; 6 and 12 weeks postoperative follow-up included clinical and radiological examination. The time required for torque measurement, the overall operating time and the number of persons present in the operating room were protocolled. BMD values of the contralateral femoral neck were postoperatively assessed by dual energy X-ray absorptiometry (DEXA) and compared to intraoperative peak torque values measured by DensiProbe. No major complication was observed during intraoperative application of DensiProbe by trained surgeons. The unintended extraction of the guide wire together with the torque measurement probe was reported only once and is looked upon as a minor complication. Fracture healing was uneventful in all patients. The mean time for torque measurement was 2.35 +/- 0.9 min accounting for 2.2 +/- 1.1% of total surgery time. The presence of an additional person was not required to perform torque measurement but to protocol the data. There was a tendency towards correlation between BMD values of the femoral neck and intraoperative peak torque values. The data presented clearly indicate that the DensiProbe instrumentation and measurement principle are eligible for routine intraoperative use by trained surgeons. Interpretation of possible correlations between BMD values measured by means of DEXA and the Peak Torque values assessed by DensiProbe has to be considered very carefully, because BMD and Peak Torque analyse bone at a different scale. Only within the framework of a multicenter study it will be possible to include a sufficient number of patients for calculation of the methods' predictive value towards implant failure and to verify acceptance of the method by the surgeons.
Klotz, Matthias C M; Beckmann, Nicholas A; Bitsch, Rudi G; Seebach, Elisabeth; Reiner, Tobias; Jäger, Sebastian
2014-11-13
In cases of poor bone quality, intraoperative torque measurement might be an alternative to preoperative dual-energy X-ray absorptiometry (DXA) to assess bone quality in total hip arthroplasty (THA). Trabecular peak torque measurement was applied in 14 paired fresh frozen human femurs. Here, a 6.5 × 23 mm wingblade was inserted into the proximal femur without harming the lateral cortical bone. Further tests of the proximal femur also evaluated bone strength (DXA, micro-computed tomography (μCT), monoaxial compression test), and the results were compared to the trabecular torque measurement. Student's t-test was used to compare the values of the groups. Pearson product-moment was applied to correlate the values of the peak torque measurement with the bone strength measured by DXA, μCT, and monoaxial compression test. In the femoral head, the mean trabecular peak torque was 4.38 ± 1.86 Nm. These values showed a strong correlation with the values of the DXA, the μCT, and the biomechanical load test (Pearson's product-moment: DXA: 0.86, μCT-BMD: 0.80, load test: 0.85). Furthermore, the torque measurement showed a more pronounced correlation with the biomechanical load test compared to the DXA. The use of this method provides highly diagnostic information about bone quality. Since the approach was adjusted for THA, no harm of the lateral bone stock will result from this measurement during surgery. The results of this initial study employing small sample sizes indicate that this new method is as sensitive as DXA in predicting bone quality and may function as an intraoperative alternative to DXA in THA. Nevertheless, before this method will turn into clinical use, more research and clinical trials are necessary.
NASA Astrophysics Data System (ADS)
Kimura, Masaaki; Inoue, Haruo; Kusaka, Masahiro; Kaizu, Koichi; Fuji, Akiyoshi
This paper describes an analysis method of the friction torque and weld interface temperature during the friction process for steel friction welding. The joining mechanism model of the friction welding for the wear and seizure stages was constructed from the actual joining phenomena that were obtained by the experiment. The non-steady two-dimensional heat transfer analysis for the friction process was carried out by calculation with FEM code ANSYS. The contact pressure, heat generation quantity, and friction torque during the wear stage were calculated using the coefficient of friction, which was considered as the constant value. The thermal stress was included in the contact pressure. On the other hand, those values during the seizure stage were calculated by introducing the coefficient of seizure, which depended on the seizure temperature. The relationship between the seizure temperature and the relative speed at the weld interface in the seizure stage was determined using the experimental results. In addition, the contact pressure and heat generation quantity, which depended on the relative speed of the weld interface, were solved by taking the friction pressure, the relative speed and the yield strength of the base material into the computational conditions. The calculated friction torque and weld interface temperatures of a low carbon steel joint were equal to the experimental results when friction pressures were 30 and 90 MPa, friction speed was 27.5 s-1, and weld interface diameter was 12 mm. The calculation results of the initial peak torque and the elapsed time for initial peak torque were also equal to the experimental results under the same conditions. Furthermore, the calculation results of the initial peak torque and the elapsed time for initial peak torque at various friction pressures were equal to the experimental results.
Recovery of pectoralis major and triceps brachii after bench press exercise.
Ferreira, Diogo V; Gentil, Paulo; Soares, Saulo Rodrigo Sampaio; Bottaro, Martim
2017-11-01
The present study evaluated and compared the recovery of pectoralis major (PM) and triceps brachii (TB) muscles of trained men after bench press exercise. Eighteen volunteers performed eight sets of bench press exercise to momentary muscle failure and were evaluated for TB and PM peak torque and total work on an isokinetic dynamometer. PM peak torque and total work remained lower than baseline for 72 and 96 h, respectively. TB peak torque was only different from baseline immediately post training, while total work was significantly lower than baseline immediately and 48 h after training. Normalized peak torque values were only different between TB and PM at 48 h after training. Considering the small and nonsignificant difference between the recovery of TB and PM muscles, the results suggest that bench press exercise may promote a similar stress on these muscles. Muscle Nerve 56: 963-967, 2017. © 2016 Wiley Periodicals, Inc.
Silva, Andressa; Mello, Marco T.; Serrão, Paula R.; Luz, Roberta P.; Bittencourt, Lia R.; Mattiello, Stela M.
2015-01-01
OBJECTIVE: The aim of this study was to investigate whether obstructive sleep apnea (OSA) alters the fluctuation of submaximal isometric torque of the knee extensors in patients with early-grade osteoarthritis (OA). METHOD: The study included 60 male volunteers, aged 40 to 70 years, divided into four groups: Group 1 (G1) - Control (n=15): without OA and without OSA; Group 2 (G2) (n=15): with OA and without OSA; Group 3 (G3) (n=15): without OA and with OSA; and Group 4 (G4) (n=15) with OA and with OSA. Five patients underwent maximal isometric contractions of 10 seconds duration each, with the knee at 60° of flexion to determine peak torque at 60°. To evaluate the fluctuation of torque, 5 submaximal isometric contractions (50% of maximum peak torque) of 10 seconds each, which were calculated from the standard deviation of torque and coefficient of variation, were performed. RESULTS: Significant differences were observed between groups for maximum peak torque, while G4 showed a lower value compared with G1 (p=0.005). Additionally, for the average torque exerted, G4 showed a lower value compared to the G1 (p=0.036). However, no differences were found between the groups for the standard deviation (p=0.844) and the coefficient of variation (p=0.143). CONCLUSION: The authors concluded that OSA did not change the parameters of the fluctuation of isometric submaximal torque of knee extensors in patients with early-grade OA. PMID:26443974
Rylands, Lee P; Roberts, Simon J; Hurst, Howard T
2015-09-01
The aim of this study was to ascertain the variation in elite male bicycle motocross (BMX) cyclists' peak power, torque, and time of power production during laboratory and field-based testing. Eight elite male BMX riders volunteered for the study, and each rider completed 3 maximal sprints using both a Schoberer Rad Messtechnik (SRM) ergometer in the laboratory and a portable SRM power meter on an Olympic standard indoor BMX track. The results revealed a significantly higher peak power (p ≤ 0.001, 34 ± 9%) and reduced time of power production (p ≤ 0.001, 105 ± 24%) in the field tests when compared with laboratory-derived values. Torque was also reported to be lower in the laboratory tests but not to an accepted level of significance (p = 0.182, 6 ± 8%). These results suggest that field-based testing may be a more effective and accurate measure of a BMX rider's peak power, torque, and time of power production.
Mahshid, Minoo; Saboury, Aboulfazl; Fayaz, Ali; Sadr, Seyed Jalil; Lampert, Friedrich; Mir, Maziar
2012-01-01
Background Mechanical torque devices (MTDs) are one of the most commonly recommended devices used to deliver optimal torque to the screw of dental implants. Recently, high variability has been reported about the accuracy of spring-style mechanical torque devices (S-S MTDs). Joint stability and survival rate of fixed implant supported prosthesis depends on the accuracy of these devices. Currently, there is limited information on the steam sterilization influence on the accuracy of MTDs. The purpose of this study was to assess the effect of steam sterilization on the accuracy (±10% of the target torque) of spring-style mechanical torque devices for dental implants. Materials and methods Fifteen new S-S MTDs and their appropriate drivers from three different manufacturers (Nobel Biocare, Straumann [ITI], and Biomet 3i [3i]) were selected. Peak torque of devices (5 in each subgroup) was measured before and after autoclaving using a Tohnichi torque gauge. Descriptive statistical analysis was used and a repeated-measures ANOVA with type of device as a between-subject comparison was performed to assess the difference in accuracy among the three groups of spring-style mechanical torque devices after sterilization. A Bonferroni post hoc test was used to assess pairwise comparisons. Results Before steam sterilization, all the tested devices stayed within 10% of their target values. After 100 sterilization cycles, results didn’t show any significant difference between raw and absolute error values in the Nobel Biocare and ITI devices; however the results demonstrated an increase of error values in the 3i group (P < 0.05). Raw error values increased with a predictable pattern in 3i devices and showed more than a 10% difference from target torque values (maximum difference of 14% from target torque was seen in 17% of peak torque measurements). Conclusion Within the limitation of this study, steam sterilization did not affect the accuracy (±10% of the target torque) of the Nobel Biocare and ITI MTDs. Raw error values increased with a predictable pattern in 3i devices and showed more than 10% difference from target torque values. Before expanding upon the clinical implications, the controlled and combined effect of aging (frequency of use) and steam sterilization needs more investigation. PMID:23674923
NASA Astrophysics Data System (ADS)
Yan, Xingting; Zhu, Ping; Sun, Youwen
2016-10-01
The characteristic profile and magnitude are predicted in theory for the neoclassical toroidal viscosity (NTV) torque induced by the plasma response to the resonant magnetic perturbation (RMP) in a tokamak with an edge pedestal, using the newly developed module coupling the NIMROD and the NTVTOK codes. For a low β equilibrium, the NTV torque is mainly induced by the dominant toroidal mode of plasma response. The NTV torque profile is radially localized and peaked, which is determined by profiles of both the equilibrium temperature and the plasma response fields. In general, the peak of NTV torque profile is found to trace the pedestal location. The magnitude of NTV torque is extremely sensitive to the β of pedestal top; for a given plasma response, the peak value of NTV torque can increase by three orders of magnitude, when the pedestal β increases by only one order of magnitude. This suggests a more significant role of NTV torque in higher plasma β regimes. Supported by the National Magnetic Confinement Fusion Program of China under Grant Nos. 2014GB124002 and 2015GB101004, and the 100 Talent Program of the Chinese Academy of Sciences.
Evaluation of fracture torque resistance of orthodontic mini-implants.
Dalla Rosa, Fernando; Burmann, Paola Fp; Ruschel, Henrique C; Vargas, Ivana A; Kramer, Paulo F
2016-12-01
This study sought to assess the fracture torque resistance of mini-implants used for orthodontic anchorage. Five commercially available brands of mini-implants were used (SIN®, CONEXÃO®, NEODENT®, MORELLI®, andFORESTADENT®). Ten mini-implants of each diameter of each brand were tested, for a total 100 specimens. The mini-implants were subject to a static torsion test as described in ASTMstandard F543. Analysis of variance (ANOVA) with the Tukey multiple comparisons procedure was used to assess results. Overall, mean fracture strength ranged from 15.7 to 70.4 N·cm. Mini-implants with larger diameter exhibited higher peak torque values at fracture and higher yield strength, regardless of brand. In addition, significant differences across brands were observed when implants were stratified by diameter. In conclusion, larger mini-implant diameter is associated with increased fracture torque resistance. Additional information on peak torque values at fracture of different commercial brands of mini-implants may increase the success rate of this orthodontic anchorage modality. Sociedad Argentina de Investigación Odontológica.
NASA Astrophysics Data System (ADS)
Taylor, M. J.; Fornusek, C.; de Chazal, P.; Ruys, A. J.
2017-10-01
Functional Electrical Stimulation (FES) activates nerves and muscles that have been ravished and rendered paralysed by disease. As such, it is advantageous to study joint torques that arise due to electrical stimulation of muscle, to measure fatigue in an indirect, minimally-invasive way. Dynamometry is one way in which this can be achieved. In this paper, torque data is presented from an FES experiment on quadriceps, using isometric dynamometry to measure torque. A library of fatigue metrics to quantify these data are put forward. These metrics include; start and end torque peaks, percentage changes in torque over time, and maximum and minimum torque period algorithms (MTPA 1 and 2), and associated torque-time plots. It is illustrated, by example, how this novel library of metrics can model fatigue over time. Furthermore, these methods are critiqued by a qualitative assessment and compared against one another for their utility in modelling fatigue. Linear trendlines with coefficients of correlation (R 2) and qualitative descriptions of data are used to achieve this. We find that although arduous, individual peak plots yield the most relevant values upon which fatigue can be assessed. Methods to calculate peaks in data have less of a utility, offset by an order of magnitude of ˜101 in comparison with theoretically expected peak numbers. In light of this, we suggest that future methods would be well-inclined to investigate optimized form of peak analysis.
Accuracy and precision of as-received implant torque wrenches.
Britton-Vidal, Eduardo; Baker, Philip; Mettenburg, Donald; Pannu, Darshanjit S; Looney, Stephen W; Londono, Jimmy; Rueggeberg, Frederick A
2014-10-01
Previous implant torque evaluation did not determine if the target value fell within a confidence interval for the population mean of the test groups, disallowing determination of whether a specific type of wrench met a standardized goal value. The purpose of this study was to measure both the accuracy and precision of 2 different configurations (spring style and peak break) of as-received implant torque wrenches and compare the measured values to manufacturer-stated values. Ten wrenches from 4 manufacturers, representing a variety of torque-limiting mechanisms and specificity of use (with either a specific brand or universally with any brand of implant product). Drivers were placed into the wrench, and tightening torque was applied to reach predetermined values using a NIST-calibrated digital torque wrench. Five replications of measurement were made for each wrench and averaged to provide a single value from that instrument. The target torque value for each wrench brand was compared to the 95% confidence interval for the true population mean of measured values to see if it fell within the measured range. Only 1 wrench brand (Nobel Biocare) demonstrated the target torque value falling within the 95% confidence interval for the true population mean. For others, the targeted torque value fell above the 95% confidence interval (Straumann and Imtec) or below (Salvin Torq). Neither type of torque-limiting mechanism nor designation of a wrench to be used as a dedicated brand-only product or to be used as a universal product on many brands affected the ability of a wrench to deliver torque values where the true population mean included the target torque level. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Assessing the therapeutic effect of 625-nm light-emitting diodes
NASA Astrophysics Data System (ADS)
Mao, Zongzhen; Xu, Guodong; Yang, Yi
2014-09-01
To evaluate the effects of red Light-Emitting Diodes on elbow extensor and flexor strength and the recovery of exercise induced fatigue, the torque values from the isokinetic dynamometer as well as biochemistry parameters were used as outcome measures. A randomized double-blind placebo-controlled crossover trial was performed with twenty male young tennis athletes. Active LED therapy (LEDT, with wavelength 625nm, 10 minutes total irradiation time, irradiated area amount to 30cm2, and 900J of total energy irradiated) or an identical placebo was delivered under double-blinded conditions to the left elbow just before exercise. The isokinetic muscle strength was measured immediately after irradiation. The blood lactate levels were sampled pre-exercise and post-exercise. The peak torque values of elbow extensor strength were significantly different between two groups. As in elbow flexor strength, the difference of peak torque was not significant. The blood lactate concentration of LEDT group post-exercise was significantly lower than those of placebo group. The results indicate that 625nm LED therapy is effective in preventing muscle fatigue as it can significantly reduce peak torque value of elbow extensors and blood lactate concentration. It has no effect on the strength of left elbow flexor or backhand performance in tennis.
Jenkins, Nathaniel D M; Buckner, Samuel L; Cochrane, Kristen C; Bergstrom, Haley C; Palmer, Ty B; Johnson, Glen O; Schmidt, Richard J; Housh, Terry J; Cramer, Joel T
2014-09-01
The purpose of this study was to compare the voluntary and evoked, absolute and normalized leg extension rates of torque development (RTD) and rates of rise in electromyography (RER) during commonly reported time intervals in young and old men. Fourteen young men (21.9±3.2years) and 16 older men (72.3±7.3years) completed three evoked and three voluntary isometric leg extension muscle actions to quantify absolute voluntary (peak, 30, 50, 100, and 200ms) and evoked (peak, 30, 50, and 100ms) RTD and RER. All RTD values were normalized (nRTD) to peak torque, while RER values were normalized (nRER) to peak-to-peak M-wave amplitude (MPP). Absolute voluntary RTDs and RERs were 58-122% and 70-76% greater (p≤0.05) for the young men, respectively. However, there were no age-related differences (p>0.05) for voluntary nRTDs, absolute and normalized evoked RTDs, or voluntary nRER. MPP and evoked RER and nRER were greater (p≤0.05) for the young men. In addition, voluntary RTD was more reliable in the young than the older men. Normalizing RTD to peak torque and RER to M-wave amplitude eliminated the age-related differences and suggested that the age-related declines in RTD and RER were a result of reduced muscle strength and M-wave amplitude, respectively. Therefore, our findings questioned the value of RTD and RER measurements in the various time intervals for explaining sarcopenia and suggested that maximal strength and M-wave amplitude may be sufficient. Copyright © 2014 Elsevier Inc. All rights reserved.
Lee, Dong-Rour; Kim, Laurentius Jongsoon
2016-08-01
Many studies have explored closed kinetic chain (CKC) shoulder exercises (SEs) with a sling because they are safer and more effective than open-chain exercises, especially in early stages of treatment. However, the application of CKC SE in youth baseball players has rarely been attempted, although teenage baseball players also experience shoulder pain. To investigate the effects of CKC SE on the peak torque of shoulder internal rotation (IR) and external rotation (ER) in youth baseball players. Single-group pretest, posttest. Biomechanics laboratory. 23 Little League Baseball players with subacromial impingement syndrome. The CKC SE with a sling was CKC shoulder-flexion exercise, extension exercise, IR exercise, and ER exercise. This exercise regimen was conducted 2 or 3 times/wk for 8 wk. The peak torque of shoulder IR and ER was measured using an isokinetic dynamometer. Concentric shoulder rotation was performed, with 5 repetitions at an angular velocity of 60°/s and 15 at 180°/s. The IR and ER peak torque significantly increased at each angular velocity after the exercise program. In particular, the increase in IR and ER peak torque values was statistically significant at an angular velocity of 180°/s. CKC SE was effective in increasing shoulder IR and ER strength, demonstrating its potential benefits in the prevention and treatment of shoulder injury. In addition, increased IR peak torque appears to improve throwing velocity in baseball players.
Two-Finger Tightness: What Is It? Measuring Torque and Reproducibility in a Simulated Model.
Acker, William B; Tai, Bruce L; Belmont, Barry; Shih, Albert J; Irwin, Todd A; Holmes, James R
2016-05-01
Residents in training are often directed to insert screws using "two-finger tightness" to impart adequate torque but minimize the chance of a screw stripping in bone. This study seeks to quantify and describe two-finger tightness and to assess the variability of its application by residents in training. Cortical bone was simulated using a polyurethane foam block (30-pcf density) that was prepared with predrilled holes for tightening 3.5 × 14-mm long cortical screws and mounted to a custom-built apparatus on a load cell to capture torque data. Thirty-three residents in training, ranging from the first through fifth years of residency, along with 8 staff members, were directed to tighten 6 screws to two-finger tightness in the test block, and peak torque values were recorded. The participants were blinded to their torque values. Stripping torque (2.73 ± 0.56 N·m) was determined from 36 trials and served as a threshold for failed screw placement. The average torques varied substantially with regard to absolute torque values, thus poorly defining two-finger tightness. Junior residents less consistently reproduced torque compared with other groups (0.29 and 0.32, respectively). These data quantify absolute values of two-finger tightness but demonstrate considerable variability in absolute torque values, percentage of stripping torque, and ability to consistently reproduce given torque levels. Increased years in training are weakly correlated with reproducibility, but experience does not seem to affect absolute torque levels. These results question the usefulness of two-finger tightness as a teaching tool and highlight the need for improvement in resident motor skill training and development within a teaching curriculum. Torque measuring devices may be a useful simulation tools for this purpose.
Predictive momentum management for a space station measurement and computation requirements
NASA Technical Reports Server (NTRS)
Adams, John Carl
1986-01-01
An analysis is made of the effects of errors and uncertainties in the predicting of disturbance torques on the peak momentum buildup on a space station. Models of the disturbance torques acting on a space station in low Earth orbit are presented, to estimate how accurately they can be predicted. An analysis of the torque and momentum buildup about the pitch axis of the Dual Keel space station configuration is formulated, and a derivation of the Average Torque Equilibrium Attitude (ATEA) is presented, for the case of no MRMS (Mobile Remote Manipulation System) motion, Y vehicle axis MRMS motion, and Z vehicle axis MRMS motion. Results showed the peak momentum buildup to be approximately 20000 N-m-s and to be relatively insensitive to errors in the predicting torque models, for Z axis motion of the MRMS was found to vary significantly with model errors, but not exceed a value of approximately 15000 N-m-s for the Y axis MRMS motion with 1 deg attitude hold error. Minimum peak disturbance momentum was found not to occur at the ATEA angle, but at a slightly smaller angle. However, this minimum peak momentum attitude was found to produce significant disturbance momentum at the end of the predicting time interval.
Effect of plyometric training on lower limb biomechanics in females.
Baldon, Rodrigo de Marche; Moreira Lobato, Daniel F; Yoshimatsu, Andre P; dos Santos, Ana Flávia; Francisco, Andrea L; Pereira Santiago, Paulo R; Serrão, Fábio V
2014-01-01
To verify the effects of plyometric training on lower limb kinematics, eccentric hip and knee torques, and functional performance. Cohort study. Research laboratory. Thirty-six females were divided into a training group (TG; n = 18) that carried out the plyometric training for 8 weeks, and a control group (CG; n = 18) that carried out no physical training. Twenty-four plyometric training sessions during approximately 8 weeks with 3 sessions per week on alternate days. Lower limb kinematics (maximum excursion of hip adduction, hip medial rotation, and knee abduction during the single leg squat), eccentric hip (abductor, adductor, medial, and lateral rotator) isokinetic peak torques and knee (flexor and extensor) isokinetic peak torques, and functional performance (triple hop test and the 6-m timed hop test). After 8 weeks, only the TG significantly reduced the values for the maximum excursion of knee abduction (P = 0.01) and hip adduction (P < 0.001). Similarly, only the TG significantly increased the eccentric hip abductor (P < 0.001) and adductor (P = 0.01) torques. Finally, only the TG significantly increased the values in the triple hop test (P < 0.001) and significantly decreased the values in the 6-m timed hop test (P < 0.001) after intervention. Plyometric training alters lower limb kinematics and increases eccentric hip torque and functional performance, suggesting the incorporation of these exercises in preventive programs for ACL injuries.
Bernard, P-L; Amato, M; Degache, F; Edouard, P; Ramdani, S; Blain, H; Calmels, P; Codine, P
2012-05-01
Although peak torque has shown acceptable reproducibility, this may not be the case with two other often used parameters: time to peak torque (TPT) and the angle of peak torque (APT). Those two parameters should be used for the characterization of muscular adaptations in athletes. The isokinetic performance of the knee extensors and flexors in both limbs was measured in 29 male athletes. The experimental protocol consisted of three consecutive identical paradigms separated by 45 min breaks. Each test consisted of four maximal concentric efforts performed at 60 and 180°/s. Reproducibility was quantified by the standard error measurement (SEM), the coefficient of variation (CV) and by means of intra-class correlation coefficients (ICCs) with the calculation of 6 forms of ICCs. Using ICC as the indicator of reproducibility, the correlations for TPT of both limbs showed a range of 0.51-0.65 in extension and 0.50-0.63 in flexion. For APT, the values were 0.46-0.60 and 0.51-0.81, respectively. In addition, the calculated standard error of measurement (SEM) and CV scores confirmed the low level of absolute reproducibility. Due to their low reproducibility, neither TPT nor APT can serve as independent isokinetic parameters of knee flexor and extensor performance. So, given its reproducibility level, TPT and APT should not be used for the characterization of muscular adaptations in athletes. Copyright © 2012 Elsevier Masson SAS. All rights reserved.
Tankevicius, Gediminas; Lankaite, Doanata; Krisciunas, Aleksandras
2013-08-01
The lack of knowledge about isometric ankle testing indicates the need for research in this area. to assess test-retest reliability and to determine the optimal position for isometric ankle-eversion and -inversion testing. Test-retest reliability study. Isometric ankle eversion and inversion were assessed in 3 different dynamometer foot-plate positions: 0°, 7°, and 14° of inversion. Two maximal repetitions were performed at each angle. Both limbs were tested (40 ankles in total). The test was performed 2 times with a period of 7 d between the tests. University hospital. The study was carried out on 20 healthy athletes with no history of ankle sprains. Reliability was assessed using intraclass correlation coefficient (ICC2,1); minimal detectable change (MDC) was calculated using a 95% confidence interval. Paired t test was used to measure statistically significant changes, and P <.05 was considered statistically significant. Eversion and inversion peak torques showed high ICCs in all 3 angles (ICC values .87-.96, MDC values 3.09-6.81 Nm). Eversion peak torque was the smallest when testing at the 0° angle and gradually increased, reaching maximum values at 14° angle. The increase of eversion peak torque was statistically significant at 7 ° and 14° of inversion. Inversion peak torque showed an opposite pattern-it was the smallest when measured at the 14° angle and increased at the other 2 angles; statistically significant changes were seen only between measures taken at 0° and 14°. Isometric eversion and inversion testing using the Biodex 4 Pro system is a reliable method. The authors suggest that the angle of 7° of inversion is the best for isometric eversion and inversion testing.
Fatigue affects peak joint torque angle in hamstrings but not in quadriceps.
Coratella, Giuseppe; Bellin, Giuseppe; Beato, Marco; Schena, Federico
2015-01-01
Primary aim of this study was to investigate peak joint torque angle (i.e. the angle of peak torque) changes recorded during an isokinetic test before and after a fatiguing soccer match simulation. Secondarily we want to investigate functional Hecc:Qconc and conventional Hconc:Qconc ratio changes due to fatigue. Before and after a standardised soccer match simulation, twenty-two healthy male amateur soccer players performed maximal isokinetic strength tests both for hamstrings and for quadriceps muscles at 1.05 rad · s(‒1), 3.14 rad · s(‒1) and 5.24 rad · s(‒1). Peak joint torque angle, peak torque and both functional Hecc:Qconc and conventional Hconc:Qconc ratios were examined. Both dominant and non-dominant limbs were tested. Peak joint torque angle significantly increased only in knee flexors. Both eccentric and concentric contractions resulted in such increment, which occurred in both limbs. No changes were found in quadriceps peak joint torque angle. Participants experienced a significant decrease in torque both in hamstrings and in quadriceps. Functional Hecc:Qconc ratio was lower only in dominant limb at higher velocities, while Hconc:Qconc did not change. This study showed after specific fatiguing task changes in hamstrings only torque/angle relationship. Hamstrings injury risk could depend on altered torque when knee is close to extension, coupled with a greater peak torque decrement compared to quadriceps. These results suggest the use eccentric based training to prevent hamstrings shift towards shorter length.
Hsieh, Chao-Jung; Indelicato, Peter A; Moser, Michael W; Vandenborne, Krista; Chmielewski, Terese L
2015-11-01
To examine the magnitude and speed of knee extensor torque production at the initiation of advanced anterior cruciate ligament (ACL) reconstruction rehabilitation and the associations with self-reported knee function. Twenty-eight subjects who were 12 weeks post-ACL reconstruction and 28 age- and sex-matched physically active controls participated in this study. Knee extensor torque was assessed bilaterally with an isokinetic dynamometer at 60°/s. The variables of interest were peak torque, average rate of torque development, time to peak torque and quadriceps symmetry index. Knee function was assessed with the International Knee Documentation Committee Subjective Knee Form (IKDC-SKF). Peak torque and average rate of torque development were lower on the surgical side compared to the non-surgical side and controls. Quadriceps symmetry index was lower in subjects with ACL reconstruction compared to controls. On the surgical side, average rate of torque development was positively correlated with IKDC-SKF score (r = 0.379) while time to peak torque was negatively correlated with IKDC-SKF score (r = -0.407). At the initiation of advanced ACL reconstruction rehabilitation, the surgical side displayed deficits in peak torque and average rate of torque development. A higher rate of torque development and shorter time to peak torque were associated with better self-reported knee function. The results suggest that the rate of torque development should be addressed during advanced ACL reconstruction rehabilitation and faster knee extensor torque generation may lead to better knee function. III.
Shoulder isokinetic profile of male handball players of the Brazilian National Team
Andrade, Marília S.; Vancini, Rodrigo L.; de Lira, Claudio A. B.; Mascarin, Naryana C.; Fachina, Rafael J. F. G.; da Silva, Antonio C.
2013-01-01
Background Data obtained on an isokinetic dynamometer are useful to characterize muscle status and have been reported in muscle imbalance studies in different types of sport. However, few studies have assessed elite handball players to establish reference values. Objective The purpose of this study was to compare, for the dominant (D) and non-dominant (ND) side, the isokinetic profile of shoulder rotator muscle strength between male handball players (H) and asymptomatic non-athletes (NA). Method Isokinetic concentric and eccentric strength tests for D upper limbs were performed by the H group (n=20) and the NA group (n=12). Internal and external rotator muscle peak torque in concentric action was assessed at 60°/s and 300°/s and in eccentric action at 300°/s. We also calculated conventional balance (the ratio of external rotator peak torque to internal rotator peak torque in concentric action) and functional balance (the ratio of external rotator peak torque in eccentric action to internal rotator peak torque in concentric action). Results In the H group, dominant limbs were stronger in concentric action for external rotation at 60 and 300°/s. The conventional balance ratio for the D side was significantly lower at 60 and 300°/s for H compared to NA. The functional ratio for the D side was significantly lower at 300º/s for H compared to NA. Conclusions Compared to asymptomatic non-athletes, handball players presented significant muscular imbalance resulting from daily sports practice, a known risk factor for shoulder injuries. PMID:24271090
Effects of hand grip exercise on shoulder joint internal rotation and external rotation peak torque.
Lee, Dong-Rour; Jong-Soon Kim, Laurentius
2016-08-10
The goal of this study is to analyze the effects of hand grip training on shoulder joint internal rotation (IR)/external rotation (ER) peak torque for healthy people. The research was conducted on 23 healthy adults in their 20 s-30 s who volunteered to participate in the experiment. Hand grip power test was performed on both hands of the research subjects before/after the test to study changes in hand grip power. Isokinetic machine was used to measure the concentric IRPT (internal rotation peak torque) and concentric ERPT (external rotation peak torque) at the velocity of 60°/sec, 90°/sec, and 180°/sec before/after the test. Hand grip training was performed daily on the subject's right hand only for four weeks according to exercise program. Finally, hand grip power of both hands and the maximum torque values of shoulder joint IR/ER were measured before/after the test and analyzed. There was a statistically significant difference in the hand grip power of the right hand, which was subject to hand grip training, after the experiment. Also, statistically significant difference for shoulder ERPT was found at 60°/sec. Hand grip training has a positive effect on shoulder joint IRPT/ERPT and therefore can help strengthen muscles around the shoulder without using weight on the shoulder. Consequently, hand grip training would help maintain strengthen the muscles around the shoulder in the early phase of rehabilitation process after shoulder surgery.
Kwon, Taek-Ka; Lee, Hyo-Jung; Min, Seung-Ki; Yeo, In-Sung
2012-10-01
To compare between a bioactive and a bioinert implant with different geometries by continuous measurement of the removal torque and calculation of the angular momentum of each surfaced implant. Six New Zealand white rabbits were used in the study. Each rabbit received 2 implants. A bioactive fluoride-modified implant with a conical connection and microthread design was inserted into one tibia, and a bioinert anodically oxidized implant with an external connection design was inserted into the other. After 2 weeks of implant insertion, the removal torque values were continuously measured according to time. Using the time-torque curve resulting from the measurements, the maximum values were determined, and the angular momenta were calculated. The anodically oxidized implant had significantly higher peak removal torque and angular momentum values than the fluoride-modified implant (P < 0.05). The impact of the fluoride-modified bioactive implant on early bone response remains unclear. Considering the angular momentum of dental implants may assist in the elucidation of the effect of implant geometry on bone response.
Thompson, Brennan J; Ryan, Eric D; Sobolewski, Eric J; Smith, Doug B; Conchola, Eric C; Akehi, Kazuma; Buckminster, Tyler
2013-03-01
The purpose of this study was to determine if maximal and rapid isometric torque characteristics could discriminate starters from nonstarters in elite Division I American collegiate football players. Sixteen starters (mean ± SD: age = 20.81 ± 1.28 years; height = 184.53 ± 6.58 cm; and mass = 108.69 ± 22.16 kg) and 15 nonstarters (20.40 ± 1.68 years; 182.27 ± 10.52 cm; and 104.60 ± 22.44 kg) performed isometric maximal voluntary contractions (MVCs) of the leg flexor and extensor muscle groups. Peak torque (PT), rate of torque development (RTD), the time to peak RTD (TTRTDpeak), contractile impulse (IMPULSE), and absolute torque values (TORQUE) at specific time intervals were calculated from a torque-time curve. The results indicated significant and nonsignificant differences between starters and nonstarters for the early rapid leg flexion torque characteristics that included RTD, IMPULSE, and TORQUE at 30 and 50 milliseconds, and TTRTDpeak. These variables also demonstrated the largest effect sizes of all the variables examined (0.71-0.82). None of the leg extensor variables, leg flexion PT, or later leg flexion rapid torque variables (≥ 100 milliseconds) were significant discriminators of playing level. These findings suggest that the early rapid leg flexion torque variables may provide an effective and sensitive muscle performance measurement in the identification of collegiate football talent. Further, coaches and practitioners may use these findings when designing training programs for collegiate football players with the intent to maximize rapid leg flexion characteristics.
NASA Technical Reports Server (NTRS)
Hackney, K. J.; English, K. L.; Redd, E.; DeWitt, J. K.; Ploutz-Snyder, R.; Ploutz-Snyder, L. L.
2010-01-01
PURPOSE: 1) To compare the test-to-test reliability of Muscle Atrophy Research and Exercise System (MARES) with a standard laboratory isokinetic dynamometer (ISOK DYN) and; 2) to determine if measures of peak torque and total work differ between devices. METHODS: Ten subjects (6M, 4F) completed two trials on both MARES and an ISOK DYN in a counterbalanced order. Peak torque values at 60 deg & 180 deg / s were obtained from five maximal repetitions of knee extension (KE) and knee flexion (KF). Total work at 180 deg / s was determined from the area under the torque vs. displacement curve during twenty maximal repetitions of KE and KF. Reliability of measures within devices was interpreted from the intraclass correlation coefficient (ICC) and compared between devices using the ratio of the within-device standard deviations. Indicators of agreement for the two devices were evaluated from: 1) a calculation of concordance (rho) and; 2) the correlation between the mean of measures versus the delta difference between measures (m u vs delta). RESULTS: For all outcome measures ICCs were high for both the ISOK DYN (0.95-0.99) and MARES (0.90-0.99). However, ratios of the within-device standard deviation were 1.3 to 4.3 times higher on MARES. On average, a wide range (3.3 to 1054 Nm) of differences existed between the values obtained. Only KE peak torque measured at 60 deg & 180 deg / s showed similarities between devices (rho = 0.91 & 0.87; Pearson's r for m u vs delta = -0.22 & -0.37, respectively). CONCLUSION: Although MARES was designed for use in microgravity it was quite reliable during ground-based testing. However, MARES was consistently more variable than an ISOK DYN. Future longitudinal studies evaluating a change in isokinetic peak torque or total work should be limited within one device.
Validity of trunk extensor and flexor torque measurements using isokinetic dynamometry.
Guilhem, Gaël; Giroux, Caroline; Couturier, Antoine; Maffiuletti, Nicola A
2014-12-01
This study aimed to evaluate the validity and test-retest reliability of trunk muscle strength testing performed with a latest-generation isokinetic dynamometer. Eccentric, isometric, and concentric peak torque of the trunk flexor and extensor muscles was measured in 15 healthy subjects. Muscle cross sectional area (CSA) and surface electromyographic (EMG) activity were respectively correlated to peak torque and submaximal isometric torque for erector spinae and rectus abdominis muscles. Reliability of peak torque measurements was determined during test and retest sessions. Significant correlations were consistently observed between muscle CSA and peak torque for all contraction types (r=0.74-0.85; P<0.001) and between EMG activity and submaximal isometric torque (r ⩾ 0.99; P<0.05), for both extensor and flexor muscles. Intraclass correlation coefficients were comprised between 0.87 and 0.95, and standard errors of measurement were lower than 9% for all contraction modes. The mean difference in peak torque between test and retest ranged from -3.7% to 3.7% with no significant mean directional bias. Overall, our findings establish the validity of torque measurements using the tested trunk module. Also considering the excellent test-retest reliability of peak torque measurements, we conclude that this latest-generation isokinetic dynamometer could be used with confidence to evaluate trunk muscle function for clinical or athletic purposes. Copyright © 2014 Elsevier Ltd. All rights reserved.
Klass, Malgorzata; Duchateau, Jacques; Enoka, Roger M.
2012-01-01
The purpose of this study was to record the discharge characteristics of tibialis anterior motor units over a range of target forces and to import these data, along with previously reported observations, into a computational model to compare experimental and simulated measures of torque variability during isometric contractions with the dorsiflexor muscles. The discharge characteristics of 44 motor units were quantified during brief isometric contractions at torques that ranged from recruitment threshold to an average of 22 ± 14.4% maximal voluntary contraction (MVC) torque above recruitment threshold. The minimal [range: 5.8–19.8 pulses per second (pps)] and peak (range: 8.6–37.5 pps) discharge rates of motor units were positively related to the recruitment threshold torque (R2 ≥ 0.266; P < 0.001). The coefficient of variation for interspike interval at recruitment was positively associated with recruitment threshold torque (R2 = 0.443; P < 0.001) and either decreased exponentially or remained constant as target torque increased above recruitment threshold torque. The variability in the simulated torque did not differ from the experimental values once the recruitment range was set to ∼85% MVC torque, and the association between motor twitch contraction times and peak twitch torque was defined as a weak linear association (R2 = 0.096; P < 0.001). These results indicate that the steadiness of isometric contractions performed with the dorsiflexor muscle depended more on the distributions of mechanical properties than discharge properties across the population of motor units in the tibialis anterior. PMID:22442023
Jesunathadas, Mark; Klass, Malgorzata; Duchateau, Jacques; Enoka, Roger M
2012-06-01
The purpose of this study was to record the discharge characteristics of tibialis anterior motor units over a range of target forces and to import these data, along with previously reported observations, into a computational model to compare experimental and simulated measures of torque variability during isometric contractions with the dorsiflexor muscles. The discharge characteristics of 44 motor units were quantified during brief isometric contractions at torques that ranged from recruitment threshold to an average of 22 ± 14.4% maximal voluntary contraction (MVC) torque above recruitment threshold. The minimal [range: 5.8-19.8 pulses per second (pps)] and peak (range: 8.6-37.5 pps) discharge rates of motor units were positively related to the recruitment threshold torque (R(2) ≥ 0.266; P < 0.001). The coefficient of variation for interspike interval at recruitment was positively associated with recruitment threshold torque (R(2) = 0.443; P < 0.001) and either decreased exponentially or remained constant as target torque increased above recruitment threshold torque. The variability in the simulated torque did not differ from the experimental values once the recruitment range was set to ∼85% MVC torque, and the association between motor twitch contraction times and peak twitch torque was defined as a weak linear association (R(2) = 0.096; P < 0.001). These results indicate that the steadiness of isometric contractions performed with the dorsiflexor muscle depended more on the distributions of mechanical properties than discharge properties across the population of motor units in the tibialis anterior.
Angular velocity affects trunk muscle strength and EMG activation during isokinetic axial rotation.
Fan, Jian-Zhong; Liu, Xia; Ni, Guo-Xin
2014-01-01
To evaluate trunk muscle strength and EMG activation during isokinetic axial rotation at different angular velocities. Twenty-four healthy young men performed isokinetic axial rotation in right and left directions at 30, 60, and 120 degrees per second angular velocity. Simultaneously, surface EMG was recorded on external oblique (EO), internal oblique (IO), and latissimus dorsi (LD) bilaterally. In each direction, with the increase of angular velocity, peak torque decreased, whereas peak power increased. During isokinetic axial rotation, contralateral EO as well as ipsilateral IO and LD acted as primary agonists, whereas, ipsilateral EO as well as contralateral IO and LD acted as primary antagonistic muscles. For each primary agonist, the root mean square values decreased with the increase of angular velocity. Antagonist coactiviation was observed at each velocity; however, it appears to be higher with the increase of angular velocity. Our results suggest that velocity of rotation has great impact on the axial rotation torque and EMG activity. An inverse relationship of angular velocity was suggested with the axial rotation torque as well as root mean square value of individual trunk muscle. In addition, higher velocity is associated with higher coactivation of antagonist, leading to a decrease in torque with the increase of velocity.
Yosmaoğlu, Hayri Baran; Baltacı, Gül; Sönmezer, Emel; Özer, Hamza; Doğan, Deha
2017-12-01
This study aims to compare the effects of anterior cruciate ligament (ACL) reconstruction using autogenous hamstring or patellar tendon graft on the peak torque angle. The study included 132 patients (103 males, 29 females; mean age 29±9 year) who were performed ACL reconstruction with autogenous hamstring or patellar tendon graft. The peak torque angles in the quadriceps and hamstring muscles were recorded using an isokinetic dynamometer. Angle of peak knee flexion torque occurred significantly earlier within the range of motion on the operated side than nonoperated side at 180°/second in the hamstring tendon group. Angle of peak knee extension torque occurred significantly earlier within the range of motion on the operated side than nonoperated side at 180°/second in the patellar tendon group. There were no statistically significant differences in the flexion and extension peak torque angles between the operated and nonoperated knees at 60°/second in both groups. The angle of peak torque at relatively high angular velocities is affected after ACL reconstruction in patients with hamstring or patellar tendon grafts. The graft donor site directly influences this parameter. This finding may be important for clinicians in terms of preventing re-injury.
NASA Technical Reports Server (NTRS)
Dudley, Gary A.; Duvoisin, Marc; Convertino, Victor A.; Buchanan, Paul
1989-01-01
The effect of a continuous 30-d-long 6-deg headdown bedrest (BR) on the force output ability of skeletal muscles was investigated in human subjects by measuring peak angle specific torque of the knee extensor (KE) and knee flexor (KF) muscle groups of both limbs during unilateral efforts at four speeds (0.52. 1.74, 2.97, and 4.19 rad/sec) during eccentric action. It was found that, for the KE muscle group, the headdown BR resulted in decreases, by 19 percent on the average, of peak angle specific torque; on the other hand, the strength of the KF muscles was not altered significantly. A post-BR recovery for 30 days was found to restore muscle strength of the KE muscle group to about 92 percent of the pre-BR values. Changes of strength were not affected by the type of speed of muscle action.
Ferreira, Diogo V; Gentil, Paulo; Ferreira-Junior, João B; Soares, Saulo R S; Brown, Lee E; Bottaro, Martim
2017-10-01
To evaluate the time course of peak torque and total work recovery after a resistance training session involving the bench press exercise. Repeated measures with a within subject design. Twenty-six resistance-trained men (age: 23.7±3.7years; height: 176.0±5.7cm; mass: 79.65±7.61kg) performed one session involving eight sets of the bench press exercise performed to momentary muscle failure with 2-min rest between sets. Shoulder horizontal adductors peak torque (PT), total work (TW), delayed onset muscle soreness (DOMS) and subjective physical fitness were measured pre, immediately post, 24, 48, 72 and 96h following exercise. The exercise protocol resulted in significant pectoralis major DOMS that lasted for 72h. Immediately after exercise, the reduction in shoulder horizontal adductors TW (25%) was greater than PT (17%). TW, as a percentage of baseline values, was also less than PT at 24, 48 and 96h after exercise. Additionally, PT returned to baseline at 96h, while TW did not. Resistance trained men presented dissimilar PT and TW recovery following free weight bench press exercise. This indicates that recovery of maximal voluntary contraction does not reflect the capability to perform multiple contractions. Strength and conditioning professionals should be cautious when evaluating muscle recovery by peak torque, since it can lead to the repetition of a training session sooner than recommended. Copyright © 2017. Published by Elsevier Inc.
Hill, Ethan C; Housh, Terry J; Camic, Clayton L; Smith, Cory M; Cochrane, Kristen C; Jenkins, Nathaniel D M; Cramer, Joel T; Schmidt, Richard J; Johnson, Glen O
2016-06-01
The purposes of this study were to examine the effects of the velocity of repeated eccentric muscle actions on the torque and neuromuscular responses during maximal isometric and eccentric muscle actions. Twelve resistance-trained men performed 30 repeated, maximal, eccentric, isokinetic muscle actions at randomly ordered velocities of 60, 120, or 180°·s on separate days. Maximal voluntary isometric contractions (MVICs) were performed before (pretest) and after (posttest) the repeated eccentric muscle actions on each day. Eccentric isokinetic peak torque (EIPT) values were the averages of the first 3 and last 3 repetitions of the 30 repeated eccentric muscle actions. During the EIPT and MVIC muscle actions, electromyographic (EMG) and mechanomyographic (MMG) amplitude (EMG AMP and MMG AMP) and mean power frequency (EMG MPF and MMG MPF) values were assessed. These results indicated that the repeated eccentric muscle actions had no effects on EIPT, or the EMG AMP, EMG MPF, or MMG MPF values assessed during the EIPT muscle actions, but decreased MMG AMP. The repeated eccentric muscle actions, however, decreased MVIC torque, and also the EMG AMP and MMG MPF values assessed during the MVIC muscle actions, but increased MMG AMP. The results indicated that the velocity of the repeated eccentric muscle actions affected the MVIC torque responses, but not EIPT or any of the neuromuscular parameters. Furthermore, there are differences in the torque and neuromuscular responses for isometric vs. eccentric muscle actions after repeated eccentric muscle actions.
Thermomechanical conditions and stresses on the friction stir welding tool
NASA Astrophysics Data System (ADS)
Atthipalli, Gowtam
Friction stir welding has been commercially used as a joining process for aluminum and other soft materials. However, the use of this process in joining of hard alloys is still developing primarily because of the lack of cost effective, long lasting tools. Here I have developed numerical models to understand the thermo mechanical conditions experienced by the FSW tool and to improve its reusability. A heat transfer and visco-plastic flow model is used to calculate the torque, and traverse force on the tool during FSW. The computed values of torque and traverse force are validated using the experimental results for FSW of AA7075, AA2524, AA6061 and Ti-6Al-4V alloys. The computed torque components are used to determine the optimum tool shoulder diameter based on the maximum use of torque and maximum grip of the tool on the plasticized workpiece material. The estimation of the optimum tool shoulder diameter for FSW of AA6061 and AA7075 was verified with experimental results. The computed values of traverse force and torque are used to calculate the maximum shear stress on the tool pin to determine the load bearing ability of the tool pin. The load bearing ability calculations are used to explain the failure of H13 steel tool during welding of AA7075 and commercially pure tungsten during welding of L80 steel. Artificial neural network (ANN) models are developed to predict the important FSW output parameters as function of selected input parameters. These ANN consider tool shoulder radius, pin radius, pin length, welding velocity, tool rotational speed and axial pressure as input parameters. The total torque, sliding torque, sticking torque, peak temperature, traverse force, maximum shear stress and bending stress are considered as the output for ANN models. These output parameters are selected since they define the thermomechanical conditions around the tool during FSW. The developed ANN models are used to understand the effect of various input parameters on the total torque and traverse force during FSW of AA7075 and 1018 mild steel. The ANN models are also used to determine tool safety factor for wide range of input parameters. A numerical model is developed to calculate the strain and strain rates along the streamlines during FSW. The strain and strain rate values are calculated for FSW of AA2524. Three simplified models are also developed for quick estimation of output parameters such as material velocity field, torque and peak temperature. The material velocity fields are computed by adopting an analytical method of calculating velocities for flow of non-compressible fluid between two discs where one is rotating and other is stationary. The peak temperature is estimated based on a non-dimensional correlation with dimensionless heat input. The dimensionless heat input is computed using known welding parameters and material properties. The torque is computed using an analytical function based on shear strength of the workpiece material. These simplified models are shown to be able to predict these output parameters successfully.
Dos Santos, Adriana Neves; Serikawa, Simoni Sayuri; Rocha, Nelci Adriana Cicuto Ferreira
2016-08-01
To verify the effect of Pilates exercises in a child with cerebral palsy (CP) with mild functional impairment. We evaluated average peak torque of ankle and knee extensors/flexors using a Biodex System, using concentric active-assisted test. We also evaluated amplitude of anterior-posterior and of medial-lateral displacement of the CoP and area of oscillation during quite standing with a BERTEC platform. We applied Pilates exercises for eight weeks. Peak torque/body weight of ankle and knee extensors/flexors of both affected and unaffected limbs increased after Pilates. Also, all kinetic variables decreased after Pilates' intervention. After one-month follow-up, isokinetic variable values were higher while kinetic variable values were lower than baseline values. Pilates may be an important rehabilitation technique for children with CP that present mild deficits in motor structures and high functional level, especially when the aims are to improve muscle strength and postural control during quite standing.
Effect of strength and speed of torque development on balance recovery with the ankle strategy.
Robinovitch, Stephen N; Heller, Britta; Lui, Andrew; Cortez, Jeffrey
2002-08-01
In the event of an unexpected disturbance to balance, the ability to recover a stable upright stance should depend not only on the magnitude of torque that can be generated by contraction of muscles spanning the lower extremity joints but also on how quickly these torques can be developed. In the present study, we used a combination of experimental and mathematical models of balance recovery by sway (feet in place responses) to test this hypothesis. Twenty-three young subjects participated in experiments in which they were supported in an inclined standing position by a horizontal tether and instructed to recover balance by contracting only their ankle muscles. The maximum lean angle where they could recover balance without release of the tether (static recovery limit) averaged 14.9 +/- 1.4 degrees (mean +/- SD). The maximum initial lean angle where they could recover balance after the tether was unexpectedly released and the ankles were initially relaxed (dynamic recovery limit) averaged 5.9 +/- 1.1 degrees, or 60 +/- 11% smaller than the static recovery limit. Peak ankle torque did not differ significantly between the two conditions (and averaged 116 +/- 32 Nm), indicating the strong effect on recovery ability of latencies in the onset and subsequent rates of torque generation (which averaged 99 +/- 13 ms and 372 +/- 267 N. m/s, respectively). Additional experiments indicated that dynamic recovery limits increased 11 +/- 14% with increases in the baseline ankle torques prior to release (from an average value of 31 +/- 18 to 54 +/- 24 N. m). These trends are in agreement with predictions from a computer simulation based on an inverted pendulum model, which illustrate the specific combinations of baseline ankle torque, rate of torque generation, and peak ankle torque that are required to attain target recovery limits.
Dirnberger, Johannes; Wiesinger, Hans-Peter; Wiemer, Nicolas; Kösters, Alexander; Müller, Erich
2016-04-01
The present study was conducted to assess test-retest reproducibility of explosive strength measurements during single-joint isometric knee extension using the IsoMed 2000 dynamometer. Thirty-one physically active male subjects (mean age: 23.7 years) were measured on two occasions separated by 48-72 h. The intraclass correlation coefficient (ICC 2,1) and the coefficient of variation (CV) were calculated for (i) maximum torque (MVC), (ii) the peak rate of torque development (RTD peak ) as well as for (iii) the average rate of torque development (RTD) and the impulse taken at several predefined time intervals (0-30 to 0-300 ms); thereby explosive strength variables were derived in two conceptually different versions: on the one hand from the MVC-trial (version I), on the other hand from the trial showing the RTD peak (version II). High ICC-values (0.80-0.99) and acceptable CV-values (1.9-8.7%) could be found for MVC as well as for the RTD and the impulse taken at time intervals of ≥100 ms, regardless of whether version I or II was used. In contrast, measurements of the RTD peak as well as the RTD and the impulse taken during the very early contraction phase (i.e. RTD/impulse 0-30ms and RTD/impulse 0-50ms ) showed clearly weaker reproducibility results (ICC: 0.53-0.84; CV: 7.3-16.4%) and gave rise to considerable doubts as to clinical usefulness, especially when derived using version I. However, if there is a need to measure explosive strength for earlier time intervals in practice, it is, in view of stronger reproducibility results, recommended to concentrate on measures derived from version II, which is based on the RTD peak -trial.
Girard, Olivier; Racinais, Sébastien; Périard, Julien D
2014-01-01
Objectives To assess the time course of changes in rapid muscle force/torque production capacity and neuromuscular activity of lower limb muscles in response to prolonged (∼2 h) match-play tennis under heat stress. Methods The rates of torque development (RTD) and electromyographic activity (EMG; ie, root mean square) rise were recorded from 0 to 30, –50, –100 and –200 ms during brief (3–5 s) explosive maximal isometric voluntary contractions (MVC) of the knee extensors (KE) and plantar flexors (PF), along with the peak RTD within the entirety of the torque-time curve. These values were recorded in 12 male tennis players before (prematch) and after (postmatch, 24 and 48 h) match-play in HOT (∼37°C) and COOL (∼22°C) conditions. Results The postmatch core temperature was greater in the HOT (∼39.4°C) vs COOL (∼38.7°C) condition (p<0.05). Reductions in KE RTD occurred within the 0–200 ms epoch after contraction onset postmatch and at 24 h, compared with prematch, independent of environmental conditions (p<0.05). A similar reduction in the KE peak RTD was also observed postmatch relative to prematch (p<0.05). No differences in KE RTD values were observed after normalisation to MVC torque. Furthermore, the rate of KE EMG activity rise remained unchanged. Conversely, the PF contractile RTD and rate of EMG activity rise were unaffected by the exercise or environmental conditions. Conclusions In the KE, a reduction in maximal torque production capacity following prolonged match-play tennis appears to account for the decrease in the rate of torque development, independent of environmental conditions, while remaining unchanged in the PF. PMID:24668381
Rotational and peak torque stiffness of rugby shoes.
Ballal, Moez S; Usuelli, Federico Giuseppe; Montrasio, Umberto Alfieri; Molloy, Andy; La Barbera, Luigi; Villa, Tomaso; Banfi, Giuseppe
2014-09-01
Sports people always strive to avoid injury. Sports shoe designs in many sports have been shown to affect traction and injury rates. The aim of this study is to demonstrate the differing stiffness and torque in rugby boots that are designed for the same effect. Five different types of rugby shoes commonly worn by scrum forwards were laboratory tested for rotational stiffness and peak torque on a natural playing surface generating force patterns that would be consistent with a rugby scrum. The overall internal rotation peak torque was 57.75±6.26 Nm while that of external rotation was 56.55±4.36 Nm. The Peak internal and external rotational stiffness were 0.696±0.1 and 0.708±0.06 Nm/deg respectively. Our results, when compared to rotational stiffness and peak torques of football shoes published in the literature, show that shoes worn by rugby players exert higher rotational and peak torque stiffness compared to football shoes when tested on the same natural surfaces. There was significant difference between the tested rugby shoes brands. In our opinion, to maximize potential performance and lower the potential of non-contact injury, care should be taken in choosing boots with stiffness appropriate to the players main playing role. Copyright © 2014 Elsevier Ltd. All rights reserved.
Chiamonti Bona, Cleiton; Tourinho Filho, Hugo; Izquierdo, Mikel; Pires Ferraz, Ricardo M; Marques, Mário C
2017-01-01
Soccer is a sport that is practiced worldwide and has been investigated in its various aspects, particularly muscle strength, which is an essential motor skill for sports performance. The objective of this study was to investigate the peak torque and muscle balance on the knee extensor and flexor of young soccer players in the tactical positions of goalkeeper, defender, full back, midfielder, defensive midfielder and striker, as well as to determine which field position has the highest peak torque. Forty-nine male players were recruited and divided into two categories during the preparatory period of the season: the Under-15 (U-15) group (N.=23, mean age 14.7±0.5 years, body mass 58.2±10.5 kg, body height 168.5±7.6 cm), and the Under-17 (U-17) group (N.=26, mean age 16.8±0.4 years, body mass 69.2±7.9 kg, body height 176.2±6.6 cm). The U-17 athletes presented a higher peak torque in all the movements of flexion and extension in the two angular velocities (i.e. 60°/s and 300°/s), but only the dominant knee extensor at 300°/s was significantly different between the two categories as well as the percentage change in peak torque compared between U-15 and U-17 was always above 20%. The peak torque variation in the U-17 category (i.e. mostly above 20%) highlights a higher peak torque compared to U-15 athletes. The muscular deficit of the two categories presented a low average of 10-15%, indicating a good muscle balance between knee extensors and flexors. Finally, goalkeepers and defenders achieved the highest peak torque amongst the field positions.
Chang, Eunwook; Norcross, Marc F; Johnson, Sam T; Kitagawa, Taichi; Hoffman, Mark
2015-02-01
The purpose of this study was to examine the relationships between maximum vertical jump height and (a) rate of torque development (RTD) calculated during 2 time intervals, 0-50 milliseconds (RTD50) and 0-200 milliseconds (RTD200) after torque onset and (b) peak torque (PT) for each of the triple extensor muscle groups. Thirty recreationally active individuals performed maximal isometric voluntary contractions (MVIC) of the hip, knee and ankle extensors, and a countermovement vertical jump. Rate of torque development was calculated from 0 to 50 (RTD50) and 0 to 200 (RTD200) milliseconds after the onset of joint torque. Peak torque was identified and defined as the maximum torque value during each MVIC trial. Greater vertical jump height was associated with greater knee and ankle extension RTD50, RTD200, and PT (p ≤ 0.05). However, hip extension RTD50, RTD200, and PT were not significantly related to maximal vertical jump height (p > 0.05). The results indicate that 47.6 and 32.5% of the variability in vertical jump height was explained by knee and ankle extensor RTD50, respectively. Knee and ankle extensor RTD50 also seemed to be more closely related to vertical jump performance than RTD200 (knee extensor: 28.1% and ankle extensor: 28.1%) and PT (knee extensor: 31.4% and ankle extensor: 13.7%). Overall, these results suggest that training specifically targeted to improve knee and ankle extension RTD, especially during the early phases of muscle contraction, may be effective for increasing maximal vertical jump performance.
Ibitoye, Morufu Olusola; Hamzaid, Nur Azah; Hasnan, Nazirah; Abdul Wahab, Ahmad Khairi; Islam, Md Anamul; Kean, Victor S P; Davis, Glen M
2016-08-01
The interaction between muscle contractions and joint loading produces torques necessary for movements during activities of daily living. However, during neuromuscular electrical stimulation (NMES)-evoked contractions in persons with spinal cord injury (SCI), a simple and reliable proxy of torque at the muscle level has been minimally investigated. Thus, the purpose of this study was to investigate the relationships between muscle mechanomyographic (MMG) characteristics and NMES-evoked isometric quadriceps torques in persons with motor complete SCI. Six SCI participants with lesion levels below C4 [(mean (SD) age, 39.2 (7.9) year; stature, 1.71 (0.05) m; and body mass, 69.3 (12.9) kg)] performed randomly ordered NMES-evoked isometric leg muscle contractions at 30°, 60° and 90° knee flexion angles on an isokinetic dynamometer. MMG signals were detected by an accelerometer-based vibromyographic sensor placed over the belly of rectus femoris muscle. The relationship between MMG root mean square (MMG-RMS) and NMES-evoked torque revealed a very high association (R(2)=0.91 at 30°; R(2)=0.98 at 60°; and R(2)=0.97 at 90° knee angles; P<0.001). MMG peak-to-peak (MMG-PTP) and stimulation intensity were less well related (R(2)=0.63 at 30°; R(2)=0.67 at 60°; and R(2)=0.45 at 90° knee angles), although were still significantly associated (P≤0.006). Test-retest interclass correlation coefficients (ICC) for the dependent variables ranged from 0.82 to 0.97 for NMES-evoked torque, between 0.65 and 0.79 for MMG-RMS, and from 0.67 to 0.73 for MMG-PTP. Their standard error of measurements (SEM) ranged between 10.1% and 31.6% (of mean values) for torque, MMG-RMS and MMG-PTP. The MMG peak frequency (MMG-PF) of 30Hz approximated the stimulation frequency, indicating NMES-evoked motor unit firing rate. The results demonstrated knee angle differences in the MMG-RMS versus NMES-isometric torque relationship, but a similar torque related pattern for MMG-PF. These findings suggested that MMG was well associated with torque production, reliably tracking the motor unit recruitment pattern during NMES-evoked muscle contractions. The strong positive relationship between MMG signal and NMES-evoked torque production suggested that the MMG might be deployed as a direct proxy for muscle torque or fatigue measurement during leg exercise and functional movements in the SCI population. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.
Bilateral pedaling asymmetry during a simulated 40-km cycling time-trial.
Carpes, F P; Rossato, M; Faria, I E; Bolli Mota, C
2007-03-01
This study investigated the pedaling asymmetry during a 40-km cycling time-trial (TT). Six sub-elite competitive male cyclists pedaled a SRM Training Systems cycle ergometer throughout a simulated 40-km TT. A SRM scientific crank dynamometer was used to measure the bilateral crank torque (N.m) and pedaling cadence (rpm). All data were analyzed into 4 stages with equal length obtained according to total time. Comparisons between each stage of the 40-km TT were made by an analysis of variance (ANOVA). Dominant (DO) and non-dominant (ND) crank peak torque asymmetry was determined by the equation: asymmetry index (AI%)=[(DO-ND)/DO] 100. Pearson correlation analysis was performed to verify the relationship between exercise intensity, mean and crank peak torque. The crank peak torque was significantly (P<0.05) greater in the 4th stage compared with other stages. During the stages 2 and 3, was observed the AI% of 13.51% and 17.28%, respectively. Exercise intensity (%VO(2max)) was greater for stage 4 (P<0.05) and was highly correlated with mean and crank peak torque (r=0.97 and r=0.92, respectively) for each stage. The DO limb was always responsible for the larger crank peak torque. It was concluded that pedaling asymmetry is present during a simulated 40-km TT and an increase on crank torque output and exercise intensity elicits a reduction in pedaling asymmetry.
Hamstrings strength imbalance in professional football (soccer) players in Australia.
Ardern, Clare L; Pizzari, Tania; Wollin, Martin R; Webster, Kate E
2015-04-01
The aim of this study was to describe the isokinetic thigh muscle strength profile of professional male football players in Australia. Concentric (60° and 240°·s(-1)) and eccentric (30° and 120°·s(-1)) hamstrings and quadriceps isokinetic strength was measured with a HUMAC NORM dynamometer. The primary variables were bilateral concentric and eccentric hamstring and quadriceps peak torque ratios, concentric hamstring-quadriceps peak torque ratios, and mixed ratios (eccentric hamstring 30°·s(-1) ÷ concentric quadriceps 240°·s(-1)). Hamstring strength imbalance was defined as deficits in any 2 of: bilateral concentric hamstring peak torque ratio <0.86, bilateral eccentric hamstring peak torque ratio <0.86, concentric hamstring-quadriceps ratio <0.47, and mixed ratio <0.80. Fifty-five strength tests involving 42 players were conducted. Ten players (24%) were identified as having hamstring strength imbalance. Athletes with strength imbalance had significantly reduced concentric and eccentric bilateral hamstring peak torque ratios at all angular velocities tested; and reduced eccentric quadriceps peak torque (30°·s(-1)) in their stance leg, compared with those without strength imbalance. Approximately, 1 in 4 players had preseason hamstring strength imbalance; and all strength deficits were observed in the stance leg. Concentric and eccentric hamstrings strength imbalance may impact in-season football performance and could have implications for the future risk of injury.
Capparé, Paolo; Vinci, Raffaele; Di Stefano, Danilo Alessio; Traini, Tonino; Pantaleo, Giuseppe; Gherlone, Enrico Felice; Gastaldi, Giorgio
2015-10-01
Quantitative intraoperative evaluation of bone quality at implant placement site and postinsertion implant primary stability assessment are two key parameters to perform implant-supported rehabilitation properly. A novel micromotor has been recently introduced allowing to measure bone density at implant placement site and to record implant insertion-related parameters, such as the instantaneous, average and peak insertion torque values, and the insertion torque/depth integral. The aim of this study was to investigate in vivo if any correlation existed between initial bone-to-implant contact (BIC) and bone density and integral values recorded with the instrument. Twenty-five patients seeking for implant-supported rehabilitation of edentulous areas were consecutively treated. Before implant placement, bone density at the insertion site was measured. For each patient, an undersized 3.3 × 8-mm implant was placed, recording the insertion torque/depth integral values. After 15 minutes, the undersized implant was retrieved with a 0.5 mm-thick layer of bone surrounding it. Standard implants were consequently placed. Retrieved implants were analyzed for initial BIC quantification after fixation, dehydration, acrylic resin embedment, sections cutting and grinding, and toluidine-blue and acid fuchsine staining. Correlation between initial BIC values, bone density at the insertion site, and the torque/depth integral values was investigated by linear regression analysis. A significant linear correlation was found to exist between initial BIC and (a) bone density at the insertion site (R = 0.96, explained variance R(2) = 0.92) and (b) torque/depth integral at placement (R = 0.81, explained variance R(2) = 0.66). The system provided quantitative, reliable data correlating significantly with immediate postinsertion initial BIC, and could therefore represent a valuable tool both for clinical research and for the oral implantologist in his/her daily clinical practice. © 2015 Wiley Periodicals, Inc.
Degidi, Marco; Daprile, Giuseppe; Piattelli, Adriano
2015-06-01
The purpose of this present study was to investigate the relation between implant site underpreparation and primary stability in the presence of poor-quality bone. A study was performed on fresh humid bovine bone; samples presented no cortical layer with a cancellous structure inside and were obtained from the hip. The bones were firmly attached to a base device. Sixty sites were prepared according to the protocol provided by the manufacturer: a 2-mm pilot drill was introduced to the proper depth and then twist drills of 3 and 3.4 mm were used. After site preparation, 20 3.4- × 11-mm (standard protocol group), 20 3.8- × 11-mm (10% undersized group), and 20 4.5- × 11-mm (25% undersized group) implants were inserted at a calibrated maximum torque of 70 N-cm at the predetermined speed of 30 rpm. After implant insertion, variable torque work (VTW), maximum insertion torque (peak IT), and resonance frequency analysis (RFA) values were recorded. The standard protocol group showed a mean VTW of 565.77 ± 219.12 N-cm, a peak IT of 11.3 ± 4.44 N-cm, and an RFA of 69.35 ± 7.35 implant stability quotient (ISQ). The 10% undersized group showed a mean VTW of 1,240.24 ± 407.78 N-cm, a peak IT of 20.26 ± 7.03 N-cm, and an RFA of 73.40 ± 2.33 ISQ. The 25% undersized group showed a mean VTW of 1,254.96 ± 727.49 N-cm, a peak IT of 17.15 ± 10.39 N-cm, and an RFA of 72.30 ± 6.70 ISQ. For VTW, the difference between the standard and undersized protocol values was statistically significant; for peak IT, the difference between the standard and 10% undersized protocol values was statistically significant; no other statistical differences were found between mean values. In the presence of poor-bone quality, a 10% undersized protocol is sufficient to improve the primary stability of the implant; additional decreases do not seem to enhance primary stability values. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Relationships between eccentric hip isokinetic torque and functional performance.
Baldon, Rodrigo de Marche; Lobato D, Ferreira Moreira; Carvalho, Lívia Pinheiro; Wun P, Yan Lam; Presotti, Cátia Valéria; Serrão, Fábio Viadanna
2012-02-01
Recently, attention in sports has been given to eccentric hip-muscle function, both in preventing musculoskeletal injuries and improving performance. To determine the key isokinetic variables of eccentric hip torque that predict the functional performance of women in the single-leg triple long jump (TLJ) and the timed 6-m single-leg hop (TH). Within-subject correlational study. Musculoskeletal laboratory. 32 healthy women age 18-25 y. The participants performed 2 sets of 5 eccentric hip-abductor/adductor and lateral/medial-rotator isokinetic contractions (30°/s) and 3 attempts in the TLJ and TH. The independent variables were the eccentric hip-abductor and -adductor and medial- and lateral-rotator isokinetic peak torque, normalized according to body mass (Nm/kg). The dependent variables were the longest distance achieved in the TLJ normalized according to body height and the shortest time spent during the execution of the TH. The forward-stepwise-regression analysis showed that the combination of the eccentric hip lateral-rotator and -abductor isokinetic peak torque provided the most efficient estimate of both functional tests, explaining 65% of the TLJ variance (P < .001) and 55% of the TH variance (P < .001). Higher values for eccentric hip lateral-rotator and hip-abductor torques reflected better performance. Thus, the eccentric action of these muscles should be considered in the development of physical training programs that aim to increase functional performance.
Sakamoto, Akihiro; Naito, Hisashi; Chow, Chin Moi
2015-07-01
Hyperventilation, implemented during recovery of repeated maximal sprints, has been shown to attenuate performance decrement. This study evaluated the effects of hyperventilation, using strength exercises, on muscle torque output and EMG amplitude. Fifteen power-trained athletes underwent maximal isokinetic knee extensions consisting of 12 repetitions × 8 sets at 60°/s and 25 repetitions × 8 sets at 300°/s. The inter-set interval was 40 s for both speeds. For the control condition, subjects breathed spontaneously during the interval period. For the hyperventilation condition, subjects hyperventilated for 30 s before each exercise set (50 breaths/min, PETCO2: 20-25 mmHg). EMG was recorded from the vastus medialis and lateralis muscles to calculate the mean amplitude for each contraction. Hyperventilation increased blood pH by 0.065-0.081 and lowered PCO2 by 8.3-10.3 mmHg from the control values (P < 0.001). Peak torque declined with repetition and set numbers for both speeds (P < 0.001), but the declining patterns were similar between conditions. A significant, but small enhancement in peak torque was observed with hyperventilation at 60°/s during the initial repetition phase of the first (P = 0.032) and fourth sets (P = 0.040). EMG amplitude also declined with set number (P < 0.001) for both speeds and muscles, which was, however, not attenuated by hyperventilation. Despite a minor ergogenic effect in peak torque at 60°/s, hyperventilation was not effective in attenuating the decrement in torque output at 300°/s and decrement in EMG amplitude at both speeds during repeated sets of maximal isokinetic knee extensions.
Kordi, Mehdi; Goodall, Stuart; Barratt, Paul; Rowley, Nicola; Leeder, Jonathan; Howatson, Glyn
2017-08-01
From a cycling paradigm, little has been done to understand the relationships between maximal isometric strength of different single joint lower body muscle groups and their relation with, and ability to predict PPO and how they compare to an isometric cycling specific task. The aim of this study was to establish relationships between maximal voluntary torque production from isometric single-joint and cycling specific tasks and assess their ability to predict PPO. Twenty male trained cyclists participated in this study. Peak torque was measured by performing maximum voluntary contractions (MVC) of knee extensors, knee flexors, dorsi flexors and hip extensors whilst instrumented cranks measured isometric peak torque from MVC when participants were in their cycling specific position (ISOCYC). A stepwise regression showed that peak torque of the knee extensors was the only significant predictor of PPO when using SJD and accounted for 47% of the variance. However, when compared to ISOCYC, the only significant predictor of PPO was ISOCYC, which accounted for 77% of the variance. This suggests that peak torque of the knee extensors was the best single-joint predictor of PPO in sprint cycling. Furthermore, a stronger prediction can be made from a task specific isometric task. Copyright © 2017 Elsevier Ltd. All rights reserved.
Vertical axis wind turbine drive train transient dynamics
NASA Technical Reports Server (NTRS)
Clauss, D. B.; Carne, T. G.
1982-01-01
Start up of a vertical axis wind turbine causes transient torque oscillations in the drive train with peak torques which may be over two and one half times the rated torque of the turbine. A computer code, based on a lumped parameter model of the drive train, was developed and tested for the low cost 17 meter turbine; the results show excellent agreement with field data. The code was used to predict the effect of a slip clutch on transient torque oscillations. It was demonstrated that a slip clutch located between the motor and brake can reduce peak torques by thirty eight percent.
Wilson, Samantha; Christensen, Bryan; Gange, Kara; Todden, Christopher; Hatterman-Valenti, Harlene; Albrecht, Jay M
2017-09-27
Chronic plantarflexor (PF) stretching during ankle immobilization helps preserve calf girth, plantarflexion peak torque, and ankle dorsiflexion (DF) motion. Immobilization can lead to decreases in muscle peak torque, muscle size, and joint ROM. Recurrent static stretching during a period of immobilization may reduce the extent of these losses. To investigate the effects of chronic static stretching on PF peak torque, calf girth, and DF range of motion (ROM) after two weeks of ankle immobilization. Randomized controlled clinical trial. Athletic training facility. Thirty-six healthy college-aged (19.81±2.48) females. Subjects were randomly assigned to one of three groups: control group, immobilized group (IM), and immobilized plus stretching group (IM+S). Each group participated in a familiarization period, a pre-test, and, two weeks later, a post-test. The IM group and IM+S group wore the Aircast FP Walker for two weeks on the left leg. During this time, the IM+S group participated in a stretching program, which consisted of two 10-minute stretching procedures each day for the 14 days. One-way ANOVA was used to determine differences in the change of ankle girth, PF peak torque, and DF ROM between groups with an α level of < 0.05. A significant difference was noted between groups in girth (F 2,31 =5.64, P=0.009), DF ROM (F 2,31 =26.13, P<0.0001), and PF peak torque (F 2,31 =7.74, P=0.002). Post-hoc testing also showed a significance difference between change in calf girth of the control group compared to the IM group (P=0.007) and a significant difference in change of peak torque in the IM+S group and the IM group (P=0.001). Also, a significant difference was shown in DF ROM between the control group and IM+S group (P=0.006), the control group and the IM group (P<0.0001), and the IM+S group and the IM group (P<0.0001). Chronic static stretching during two weeks of immobilization may decrease the loss of calf girth, ankle PF peak torque, and ankle DF ROM.
Morel, Baptiste; Rouffet, David M; Saboul, Damien; Rota, Samuel; Clémençon, Michel; Hautier, Christophe A
2015-01-01
Rapid force production is critical to improve performance and prevent injuries. However, changes in rate of force/torque development caused by the repetition of maximal contractions have received little attention. The aim of this study was to determine the relative influence of rate of torque development (RTD) and peak torque (T(peak)) on the overall performance (i.e. mean torque, T(mean)) decrease during repeated maximal contractions and to investigate the contribution of contractile and neural mechanisms to the alteration of the various mechanical variables. Eleven well-trained men performed 20 sets of 6-s isokinetic maximal knee extensions at 240° · s(-1), beginning every 30 seconds. RTD, T(peak) and T(mean) as well as the Rate of EMG Rise (RER), peak EMG (EMG(peak)) and mean EMG (EMG(mean)) of the vastus lateralis were monitored for each contraction. A wavelet transform was also performed on raw EMG signal for instant mean frequency (if(mean)) calculation. A neuromuscular testing procedure was carried out before and immediately after the fatiguing protocol including evoked RTD (eRTD) and maximal evoked torque (eT(peak)) induced by high frequency doublet (100 Hz). T(mean) decrease was correlated to RTD and T(peak) decrease (R(²) = 0.62; p<0.001; respectively β=0.62 and β=0.19). RER, eRTD and initial if(mean) (0-225 ms) decreased after 20 sets (respectively -21.1 ± 14.1, -25 ± 13%, and ~20%). RTD decrease was correlated to RER decrease (R(²) = 0.36; p<0.05). The eT(peak) decreased significantly after 20 sets (24 ± 5%; p<0.05) contrary to EMG(peak) (-3.2 ± 19.5 %; p=0.71). Our results show that reductions of RTD explained part of the alterations of the overall performance during repeated moderate velocity maximal exercise. The reductions of RTD were associated to an impairment of the ability of the central nervous system to maximally activate the muscle in the first milliseconds of the contraction.
Mascarin, Naryana C.; Vargas, Valentine Z.; Vancini, Rodrigo L.; Andrade, Marília S.
2017-01-01
Background Anterior cruciate ligament injury is higher in soccer athletes as compared to athletes of other sports. Risk factors for anterior cruciate ligament injury include low knee hamstring/quadriceps strength ratio and bilateral strength deficits. Purpose To investigate isokinetic thigh muscles strength, hamstring/quadriceps strength ratio, and bilateral strength comparisons in athletes who participate in professional soccer, futsal, and beach soccer. Study Design Cross-sectional study. Methods Brazilian professional soccer (n=70), futsal (n=30), and beach soccer (n=12) players were isokinetically assessed to examine strength of knee extensors and flexors at 60 degrees/second in concentric mode, to measure peak torque of dominant and non-dominant limbs. Results In the dominant limb, for extensors muscles, futsal players presented significantly lower peak torque values (223.9 ± 33.4 Nm) than soccer (250.9 ± 43.0 Nm; p=0.02) and beach soccer players (253.1 ± 32.4 Nm; p=0.03). Peak torque for extensor muscles in the non-dominant limb was significantly lower in futsal (224.0 ± 35.8 Nm) than in beach soccer players (256.8 ± 39.8 Nm; p=0.03). Hamstring/quadriceps strength ratio for dominant limbs for futsal (57.6 ± 10.1%), soccer (53.5 ± 8.8%), and beach soccer (56.3 ± 8.4%) players presented no significant differences between groups; however, the mean values were lower than recommended values found in the literature. There were no strength deficits for any of the evaluated groups when compared bilaterally. Conclusions Futsal athletes presented lower values for quadriceps strength than soccer and beach soccer athletes. Futsal, soccer, and beach soccer players presented no strength asymmetries, but they presented with strength imbalance in hamstring/quadriceps strength ratio. Level of Evidence 3 PMID:29234562
Rosene, J M; Matthews, T D; Mcbride, K J; Galla, A; Haun, M; Mcdonald, K; Gagne, N; Lea, J; Kasen, J; Farias, C
2015-12-01
The purpose of this investigation was to determine the effects of 3 d of creatine supplementation on thermoregulation and isokinetic muscular performance. Fourteen males performed two exercise bouts following 3 d of creatine supplementation and placebo. Subjects exercised for 60 min at 60-65% of VO2max in the heat followed by isokinetic muscular performance at 60, 180, and 300°·s(-1). Dependent variables for pre- and postexercise included nude body weight, urine specific gravity, and serum creatinine levels. Total body water, extracellular water and intracellular water were measured pre-exercise. Core temperature was assessed every 5 min during exercise. Peak torque and Fatigue Index were used to assess isokinetic muscular performance. Core temperature increased during the run for both conditions. Total body water and extracellular water were significantly greater (P<0.05) following creatine supplementation. No significant difference (P>0.05) was found between conditions for intracellular water, nude body weight, urine specific gravity, and serum creatinine. Pre-exercise scores for urine specific gravity and serum creatinine were significantly less (P<0.05) versus post-exercise. No significant differences (P>0.05) were found in peak torque values or Fatigue Index between conditions for each velocity. A significant (P<0.05) overall velocity effect was found for both flexion and extension. As velocity increased, mean peak torque values decreased. Three d of creatine supplementation does not affect thermoregulation during submaximal exercise in the heat and is not enough to elicit an ergogenic effect for isokinetic muscle performance following endurance activity.
Francis, Peter; Toomey, Clodagh; Mc Cormack, William; Lyons, Mark; Jakeman, Philip
2017-07-01
Muscle quality is defined as strength per unit muscle mass. The aim of this study was to measure the maximal voluntary isometric torque of the knee extensor and flexor muscle groups in healthy older women and to develop an index of muscle quality based on the combined knee extensor and flexor torque per unit lean tissue mass (LTM) of the upper leg. One hundred and thirty-six healthy 50- to 70-year-old women completed an initial measurement of isometric peak torque of the knee extensors and flexors (Con-Trex MJ; CMV AG, Dubendorf, Switzerland) that was repeated 7 days later. Subsequently, 131 women returned for whole- and regional-body composition analysis (iDXA ™ ; GE Healthcare, Chalfont St Giles, Buckinghamshire, UK). Isometric peak torque demonstrated excellent within-assessment reliability for both the knee extensors and flexors (ICC range: 0·991-1·000). Test-retest reliability was lower (ICC range: 0·777-0·828) with an observed mean increase of 5% in peak torque [6·2 (17·2) N m] on the second day of assessment (P<0·001). The relative mean decrease in combined isometric peak torque (-12·2%; P = 0·001) was double that of the relative, non-significant, median difference in upper leg LTM (-5·3%; P = 0·102) between those in the 5th and 6th decade. The majority of difference in peak isometric torque came from the knee extensors (15·1 N m, P<0·001 versus 2·4 N m, P = 0·234). Isometric peak torque normalized for upper leg LTM (muscle quality) was 8% lower between decades (P = 0·029). These findings suggest strength per unit tissue may provide a better indication of age-related differences in muscle quality prior to change in LTM. © 2016 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.
Apostolopoulos, Nikos C; Lahart, Ian M; Plyley, Michael J; Taunton, Jack; Nevill, Alan M; Koutedakis, Yiannis; Wyon, Matthew; Metsios, George S
2018-03-12
Effects of passive static stretching intensity on recovery from unaccustomed eccentric exercise of right knee extensors was investigated in 30 recreationally active males randomly allocated into three groups: high-intensity (70-80% maximum perceived stretch), low-intensity (30-40% maximum perceived stretch), and control. Both stretching groups performed 3 sets of passive static stretching exercises of 60s each for hamstrings, hip flexors, and quadriceps, over 3 consecutive days, post-unaccustomed eccentric exercise. Muscle function (eccentric and isometric peak torque) and blood biomarkers (CK and CRP) were measured before (baseline) and after (24, 48, and 72h) unaccustomed eccentric exercise. Perceived muscle soreness scores were collected immediately (time 0), and after 24, 48, and 72h post-exercise. Statistical time x condition interactions observed only for eccentric peak torque (p=.008). Magnitude-based inference analyses revealed low-intensity stretching had most likely, very likely, or likely beneficial effects on perceived muscle soreness (48-72h and 0-72h) and eccentric peak torque (baseline-24h and baseline-72h), compared with high-intensity stretching. Compared with control, low-intensity stretching had very likely or likely beneficial effects on perceived muscle soreness (0-24h and 0-72h), eccentric peak torque (baseline-48h and baseline-72h), and isometric peak torque (baseline-72h). High-intensity stretching had likely beneficial effects on eccentric peak torque (baseline-48h), but likely harmful effects eccentric peak torque (baseline-24h) and CK (baseline-48h and baseline-72h), compared with control. Therefore, low-intensity stretching is likely to result in small-to-moderate beneficial effects on perceived muscle soreness and recovery of muscle function post-unaccustomed eccentric exercise, but not markers of muscle damage and inflammation, compared with high-intensity or no stretching.
Andrade, Marilia Dos Santos; De Lira, Claudio Andre Barbosa; Koffes, Fabiana De Carvalho; Mascarin, Naryana Cristina; Benedito-Silva, Ana Amélia; Da Silva, Antonio Carlos
2012-01-01
The purpose of this study was to determine differences in hamstrings-to-quadriceps (H/Q) peak torque ratios evaluated at different angular velocities between men and women who participate in judo, handball or soccer. A total of 166 athletes, including 58 judokas (26 females and 32 males), 39 handball players (22 females and 17 males), and 69 soccer players (17 females and 52 males), were evaluated using an isokinetic dynamometer. The H/Q isokinetic peak torque ratios were calculated at angular velocities of 1.05 rad · s⁻¹ and 5.23 rad · s⁻¹. In the analysis by gender, female soccer players produced lower H/Q peak torque ratios at 1.05 rad · s⁻¹ than males involved in the same sport. However, when H/Q peak torque ratio was assessed at 5.23 rad · s⁻¹, there were no significant differences between the sexes. In the analysis by sport, there were no differences among females at 1.05 rad · s⁻¹. In contrast, male soccer players had significantly higher H/Q peak torque ratios than judokas (66 ± 12% vs. 57 ± 14%, respectively). Female handball players produced significantly lower peak torque ratios at 5.23 rad · s⁻¹ than judokas or soccer players, whereas males presented no ratio differences among sports At 5.23 rad · s⁻¹. In the analysis by velocity, women's muscular ratios assessed at 1.05 rad · s⁻¹ were significantly lower than at 5.23 rad · s⁻¹ for all sports; among men, only judokas presented lower ratios at 1.05 rad · s⁻¹ than at 5.23 rad · s⁻¹. The present results suggest that sport modality and angular velocity influence the isokinetic strength profiles of men and women.
Grote, Stefan; Noeldeke, Tatjana; Blauth, Michael; Mutschler, Wolf; Bürklein, Dominik
2013-06-07
Knowledge of local bone quality is essential for surgeons to determine operation techniques. A device for intraoperative measurement of local bone quality has been developed by the AO-Research Foundation (Densi - Probe®). We used this device to experimentally measure peak breakaway torque of trabecular bone in the proximal femur and correlated this with local bone mineral density (BMD) and failure load. Bone mineral density of 160 cadaver femurs was measured by ex situ dualenergy X-ray absorptiometry. The failure load of all femurs was analyzed by side-impact analysis. Femur fractures were fixed and mechanical peak torque was measured with the DensiProbe® device. Correlation was calculated whereas correlation coefficient and significance was calculated by Fisher's Ztransformation. Moreover, linear regression analysis was carried out. The unpaired Student's t-test was used to assess the significance of differences. The Ward triangle region had the lowest BMD with 0.511 g/cm(2) (±0.17 g/cm(2)), followed by the upper neck region with 0.546 g/cm(2) (±0.16 g/cm(2)), trochanteric region with 0.685 g/cm(2) (±0.19 g/cm(2)) and the femoral neck with 0.813 g/cm(2) (±0.2 g/cm(2)). Peak torque of DensiProbe® in the femoral head was 3.48 Nm (±2.34 Nm). Load to failure was 4050.2 N (±1586.7 N). The highest correlation of peak torque measured by Densi Probe® and load to failure was found in the femoral neck (r=0.64, P<0.001). The overall correlation of mechanical peak torque with T-score was r=0.60 (P<0.001). A correlation was found between mechanical peak torque, load to failure of bone and BMD in vitro. Trabecular strength of bone and bone mineral density are different aspects of bone strength, but a correlation was found between them. Mechanical peak torque as measured may contribute additional information about bone strength, especially in the perioperative testing.
Experimental evaluation of a high performance superconducting torquer
NASA Astrophysics Data System (ADS)
Goldie, James H.; Avakian, Kevin M.; Downer, James R.; Gerver, Michael; Gondhalekar, Vijay; Johnson, Bruce G.
The high performance superconducting torquer (HPSCT) was designed to slew a large inertia in one degree of freedom with a double versine torque profile, a profile used for pointing applications which minimizes the exciting of structural resonances. The program culminated with the successful demonstration of closed loop torque control, following a desired double versine torque profile to an accuracy of approximately 1 percent of the peak torque of the profile. The targeted double versine possessed a peak torque which matches the torque capacity of the Sperry M4500 CMG (controlled moment gyro). The research provided strong evidence of the feasibility of an advanced concept CMG which would use cryoresistive control coils in conjunction with an electromagnetically suspended rotor and superconducting source coil. The cryoresistive coils interact with the superconducting solenoid to develop the desired torque and, in addition, the required suspension forces.
Torque, power and muscle activation of eccentric and concentric isokinetic cycling.
Green, David J; Thomas, Kevin; Ross, Emma Z; Green, Steven C; Pringle, Jamie S M; Howatson, Glyn
2018-06-01
This study aimed to establish the effect of cycling mode and cadence on torque, external power output, and lower limb muscle activation during maximal, recumbent, isokinetic cycling. After familiarisation, twelve healthy males completed 6 × 10 s of maximal eccentric (ECC) and concentric (CON) cycling at 20, 40, 60, 80, 100, and 120 rpm with five minutes recovery. Vastus lateralis, medial gastrocnemius, rectus femoris, and biceps femoris surface electromyography was recorded throughout. As cadence increased, peak torque linearly decreased during ECC (350-248 N·m) and CON (239-117 N·m) and peak power increased in a parabolic manner. Crank angle at peak torque increased with cadence in CON (+13°) and decreased in ECC (-9.0°). At all cadences, peak torque (mean +129 N·m, range 111-143 N·m), and power (mean +871 W, range 181-1406 W), were greater during ECC compared to CON. For all recorded muscles the crank angle at peak muscle activation was greater during ECC compared to CON. This difference increased with cadence in all muscles except the vastus lateralis. Additionally, peak vastus laterallis and biceps femoris activation was greater during CON compared to ECC. Eccentric cycling offers a greater mechanical stimulus compared to concentric cycling but the effect of cadence is similar between modalities. Markers of technique (muscle activation, crank angle at peak activation and torque) were different between eccentric and concentric cycling and respond differently to changes in cadence. Such data should be considered when comparing between, and selecting cadences for, recumbent, isokinetic, eccentric and concentric cycling. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.
Rate of muscle contraction is associated with cognition in women, not in men.
Tian, Qu; Osawa, Yusuke; Resnick, Susan M; Ferrucci, Luigi; Studenski, Stephanie A
2018-05-08
In older persons, lower hand grip strength is associated with poorer cognition. Little is known about how the rate of muscle contraction relates to cognition and upper extremity motor function, and sex differences are understudied. Linear regression, adjusting for age, race, education, body mass index, appendicular lean mass, and knee pain assessed sex-specific cross-sectional associations of peak torque, rate of torque development (RTD) and rate of velocity development (RVD) with cognition and upper extremity motor function. In men (n=447), higher rate-adjusted peak torque and a greater RVD were associated with faster simple finger tapping speed, and a greater RVD was associated with higher nondominant pegboard performance. In women (n=447), higher peak torque was not associated with any measures, but a greater RTD was associated with faster simple tapping speed and higher language performance, and a greater RVD was associated with higher executive function, attention, memory, and nondominant pegboard performance. In women with low isokinetic peak torque, RVD was associated with attention and memory. RVD capacity may reflect neural health, especially in women with low muscle strength.
Król, P; Sobota, G; Polak, A; Bacik, B; Juras, G
2017-01-01
Whole-body vibration training has become a popular method used in sports and physiotherapy. The study aimed to evaluate the effect of different vibration frequency and peak-to-peak displacement combinations on men knee flexors and extensors strength in isokinetic conditions. The sample consisted of 49 male subjects randomly allocated to seven comparative groups, six of which exercised on a vibration platform with parameters set individually for the groups. The experimental groups were exposed to vibrations 3 times a week for 4 weeks. The pre- and post- isokinetic strength tests, with the angular velocities of 240°/s and 30°/s, were recorded prior to and 2 days after the training. After 4 weeks of whole-body vibration training, a significant increase was noted regarding the mean values of peak torque, average peak torque and total work for knee flexors at high angular velocity in Groups I (60 Hz/4 mm) and V (40 Hz/2 mm) (p<0.05). The mean percentage values of post-training changes to study parameters suggest that the training had the most beneficial effect in Groups I (60 Hz/4 mm) and IV (60 Hz/2 mm) (p<0.05). Whole-body vibrations during static exercise beneficially affected knee flexor strength profile in young men at high angular velocity. The combinations of 60 Hz/4 mm seem to have the most advantageous effects on muscle strength parameters. PMID:28566806
de Vasconcelos, Rodrigo Antunes; Bevilaqua-Grossi, Débora; Shimano, Antonio Carlos; Jansen Paccola, Cleber Antonio; Salvini, Tânia Fátima; Prado, Christiane Lanatovits; Mello Junior, Wilson A.
2015-01-01
The aim of this study was to analyze the correlation between deficits in the isokinetic peak torque of the knee extensors and flexors with hop tests, postoperative knee laxity and functional scores in normal and ACL- reconstructed subjects with patellar tendon and hamstring tendon autografts. Methods: Sixty male subjects were enrolled and subdivided into three groups: Twenty subjects without knee injuries (GC group) and two groups of 20 subjects submitted to ACL reconstruction with patellar tendon (GTP group) and hamstrings autograft (GTF group). Results: The results showed significant correlation between knee extensors peak torque and performance in the hop tests for GTF and GC groups. There are no significantly correlations between post op knee laxity and Lysholm score compared with the hop tests and peak torque deficits. Concerning the differences between groups, the GTP group showed greater peak torque deficits in knee extensors, worst Lysholm scores and higher percentage of individuals with lower limb symmetry index (ISM) < 90% in both hop tests when compared to the other two groups. Conclusion: It is not recommendable to use only one measurement instrument for the functional evaluation of ACL-reconstructed patients, because significant correlation between peak torque, subject's functional score, knee laxity and hop tests were not observed in all groups. PMID:26998464
Callahan, Damien M.; Umberger, Brian R.; Kent-Braun, Jane A.
2013-01-01
The pathway of voluntary joint torque production includes motor neuron recruitment and rate-coding, sarcolemmal depolarization and calcium release by the sarcoplasmic reticulum, force generation by motor proteins within skeletal muscle, and force transmission by tendon across the joint. The direct source of energetic support for this process is ATP hydrolysis. It is possible to examine portions of this physiologic pathway using various in vivo and in vitro techniques, but an integrated view of the multiple processes that ultimately impact joint torque remains elusive. To address this gap, we present a comprehensive computational model of the combined neuromuscular and musculoskeletal systems that includes novel components related to intracellular bioenergetics function. Components representing excitatory drive, muscle activation, force generation, metabolic perturbations, and torque production during voluntary human ankle dorsiflexion were constructed, using a combination of experimentally-derived data and literature values. Simulation results were validated by comparison with torque and metabolic data obtained in vivo. The model successfully predicted peak and submaximal voluntary and electrically-elicited torque output, and accurately simulated the metabolic perturbations associated with voluntary contractions. This novel, comprehensive model could be used to better understand impact of global effectors such as age and disease on various components of the neuromuscular system, and ultimately, voluntary torque output. PMID:23405245
Yoo, Jinho; Kim, Bo-Hyung; Kim, Soo-Hwan; Kim, Yangseok; Yim, Sung-Vin
2016-05-01
The study aimed to identify single nucleotide polymorphisms (SNPs) that significantly influenced the level of improvement of two kinds of training responses, including maximal O2 uptake (V'O2max) and knee peak torque of healthy adults participating in the high intensity training (HIT) program. The study also aimed to use these SNPs to develop prediction models for individual training responses. 79 Healthy volunteers participated in the HIT program. A genome-wide association study, based on 2,391,739 SNPs, was performed to identify SNPs that were significantly associated with gains in V'O2max and knee peak torque, following 9 weeks of the HIT program. To predict two training responses, two independent SNPs sets were determined using linear regression and iterative binary logistic regression analysis. False discovery rate analysis and permutation tests were performed to avoid false-positive findings. To predict gains in V'O2max, 7 SNPs were identified. These SNPs accounted for 26.0 % of the variance in the increment of V'O2max, and discriminated the subjects into three subgroups, non-responders, medium responders, and high responders, with prediction accuracy of 86.1 %. For the knee peak torque, 6 SNPs were identified, and accounted for 27.5 % of the variance in the increment of knee peak torque. The prediction accuracy discriminating the subjects into the three subgroups was estimated as 77.2 %. Novel SNPs found in this study could explain, and predict inter-individual variability in gains of V'O2max, and knee peak torque. Furthermore, with these genetic markers, a methodology suggested in this study provides a sound approach for the personalized training program.
Initial Design and Experimental Evaluation of a Pneumatic Interference Actuator.
Nesler, Christopher R; Swift, Tim A; Rouse, Elliott J
2018-04-01
Substantial device mass and control complexity can hinder the impact of wearable robotic technologies, such as exoskeletons. Thus, despite promising previous research, the development of a simple, lightweight actuator for these systems has not yet been fully realized. The purpose of this study was to derive and demonstrate a proof-of-concept for a pneumatic interference actuator (PIA)-a lightweight, soft actuator able to produce torque by the self-intersection of a fabric balloon that arises from changes in physical geometry. General closed-form equations are derived to express the expected actuator torque and mechanical work as functions of the balloon geometry, pressure, and deflection angle. Hard and soft cylindrical physical prototypes were constructed to assess the accuracy of the mathematical models. The proposed mathematical model was found to agree with the pressure-volume relationship and successfully predict the maximum torque as a function of geometry, pressure, and deflection at nonzero deflection angles. Peak powers up to 122.1 ± 10.0 W (mean ± standard deviation), with a resting internal pressure of 158.0 ± 0.2 kPa, were observed from the hard actuator prototype. For the soft actuator prototype, peak powers of 97.9 ± 21.1 W were observed at a resting pressure of 166.8 kPa. The work performed was within 3.2% ± 3.4% and 14.4% ± 8.2% of theoretical values across all trials, and within 19.1% ± 4.4% of theoretical values when compared to the torque-angle relationship. This study highlights the promise of utilizing the self-intersection of a PIA to perform human-scale mechanical work, and future research will focus on implementations for wearable robotic systems.
Torque-onset determination: Unintended consequences of the threshold method.
Dotan, Raffy; Jenkins, Glenn; O'Brien, Thomas D; Hansen, Steve; Falk, Bareket
2016-12-01
Compared with visual torque-onset-detection (TOD), threshold-based TOD produces onset bias, which increases with lower torques or rates of torque development (RTD). To compare the effects of differential TOD-bias on common contractile parameters in two torque-disparate groups. Fifteen boys and 12 men performed maximal, explosive, isometric knee-extensions. Torque and EMG were recorded for each contraction. Best contractions were selected by peak torque (MVC) and peak RTD. Visual-TOD-based torque-time traces, electromechanical delays (EMD), and times to peak RTD (tRTD) were compared with corresponding data derived from fixed 4-Nm- and relative 5%MVC-thresholds. The 5%MVC TOD-biases were similar for boys and men, but the corresponding 4-Nm-based biases were markedly different (40.3±14.1 vs. 18.4±7.1ms, respectively; p<0.001). Boys-men EMD differences were most affected, increasing from 5.0ms (visual) to 26.9ms (4Nm; p<0.01). Men's visually-based torque kinetics tended to be faster than the boys' (NS), but the 4-Nm-based kinetics erroneously depicted the boys as being much faster to any given %MVC (p<0.001). When comparing contractile properties of dissimilar groups, e.g., children vs. adults, threshold-based TOD methods can misrepresent reality and lead to erroneous conclusions. Relative-thresholds (e.g., 5% MVC) still introduce error, but group-comparisons are not confounded. Copyright © 2016 Elsevier Ltd. All rights reserved.
[Sincerity of effort: isokinetic evaluation of knee extension].
Colombo, R; Demaiti, G; Sartorio, F; Orlandini, D; Vercelli, S; Ferriero, G
2008-01-01
The aim of this study was to find a reliable method to evaluate the sincerity of the muscular maximal effort performed in a dynamometric isokinetic test of knee flexion-extension. The coefficient of variation of the peak torque (CV) and 3 new indices were analysed: (1) the average coefficient of variation calculated on the complete peak torque curve (CVM); (2) the slope of the regression line in an endurance test (PRR); (3) the correlation coefficient of the peak torques in the same endurance test (CCR). Twenty healthy subjects underwent assessment in two different trials, maximal (MX) and 50% submaximal (SMX), with 20 minutes of rest between trials. Each trial consisted of 4 tests, each of 3 repetitions, at angular speed of 30, 180, 30, and 180 degrees/s, respectively, and 1 test of 15 repetitions at 240 degrees/s. Our findings confirmed the ability of CV to detect a high percentage of sincere efforts: at 30 degrees/s Sensibility (Sns)=100% and Specificity (Spc)=70%; at 180 degrees/s Sns=75%, Spc=95%. The 3 new indices here proposed showed high characteristics of Sns and Spc, generally better than those of CV. CVM showed at 180 degrees/s Sns=90% and Spc=100%, while at 30 degrees/s Sns=90%, Spc=75%. PRR was the best index identifying all the efforts, except one (Sns=100%, Spc=95%). The CCR coefficient showed Sns and Spc values both of 90%.
Muscle damage and repeated bout effect induced by enhanced eccentric squats.
Coratella, Giuseppe; Chemello, Alessandro; Schena, Federico
2016-12-01
Muscle damage and repeated bout effect have been studied after pure eccentric-only exercise. The aim of this study was to evaluate muscle damage and repeated bout effect induced by enhanced eccentric squat exercise using flywheel device. Thirteen healthy males volunteered for this study. Creatine kinase blood activity (CK), quadriceps isometric peak torque and muscle soreness were used as markers of muscle damage. The dependent parameters were measured at baseline, immediately after and each day up to 96 hours after the exercise session. The intervention consisted of 100 repetitions of enhanced eccentric squat exercise using flywheel device. The same protocol was repeated after 4 weeks. After the first bout, CK and muscle soreness were significantly greater (P<0.05) than baseline respectively up to 72 and 96 hours. Isometric peak torque was significantly lower (P<0.05) up to 72 hours. After the second bout, CK showed no significant increase (P>0.05), while isometric peak torque and muscle soreness returned to values similar to baseline after respectively 48 and 72 hours. All muscle damage markers were significantly lower after second compared to first bout. The enhanced eccentric exercise induced symptoms of muscle damage up to 96 hours. However, it provided muscle protection after the second bout, performed four weeks later. Although it was not eccentric-only exercise, the enhancement of eccentric phase provided muscle protection.
Matthews, Martyn J; Heron, Kate; Todd, Stefanie; Tomlinson, Andrew; Jones, Paul; Delextrat, Anne; Cohen, Daniel D
2017-05-01
To investigate the effect of two hamstring training protocols on eccentric peak torque before and after soccer specific fatigue. Twenty-two university male soccer players. Isokinetic strength tests were performed at 60°/s pre and post fatigue, before and after 2 different training interventions. A 45-min soccer specific fatigue modified BEAST protocol (M-BEAST) was used to induce fatigue. Players were randomly assigned to a 4 week hamstrings conditioning intervention with either a maximum strength (STR) or a muscle endurance (END) emphasis. The following parameters were evaluated: Eccentric peak torque (EccPT), angle of peak torque (APT), and angle specific torques at knee joint angles of 10°, 20°, 30°, 40°, 50°, 60°, 70°, 80° and 90°. There was a significant effect of the M-BEAST on the Eccentric torque angle profile before training as well as significant improvements in post-fatigue torque angle profile following the effects of both strength and muscle endurance interventions. Forty-five minutes of simulated soccer activity leads to reduced eccentric hamstring torque at longer muscle lengths. Short-term conditioning programs (4-weeks) with either a maximum strength or a muscular endurance emphasis can equally reduce fatigue induced loss of strength over this time period. Copyright © 2017 Elsevier Ltd. All rights reserved.
Oh, Youkeun K.; Kreinbrink, Jennifer L.; Wojtys, Edward M.; Ashton-Miller, James A.
2011-01-01
Anterior cruciate ligament (ACL) injuries most frequently occur under the large loads associated with a unipedal jump landing involving a cutting or pivoting maneuver. We tested the hypotheses that internal tibial torque would increase the anteromedial (AM) bundle ACL relative strain and strain rate more than would the corresponding external tibial torque under the large impulsive loads associated with such landing maneuvers. Twelve cadaveric female knees [mean (SD) age: 65.0 (10.5) years] were tested. Pretensioned quadriceps, hamstring and gastrocnemius muscle-tendon unit forces maintained an initial knee flexion angle of 15°. A compound impulsive test load (compression, flexion moment and internal or external tibial torque) was applied to the distal tibia while recording the 3-D knee loads and tibofemoral kinematics. AM-ACL relative strain was measured using a 3mm DVRT. In this repeated measures experiment, the Wilcoxon Signed-Rank test was used to test the null hypotheses with p<0.05 considered significant. The mean (± SD) peak AM-ACL relative strains were 5.4±3.7 % and 3.1±2.8 % under internal and external tibial torque, respectively. The corresponding mean (± SD) peak AM-ACL strain rates reached 254.4±160.1 %/sec and 179.4±109.9 %/sec, respectively. The hypotheses were supported in that the normalized mean peak AM-ACL relative strain and strain rate were 70% and 42% greater under internal than external tibial torque, respectively (p=0.023, p=0.041). We conclude that internal tibial torque is a potent stressor of the ACL because it induces a considerably (70%) larger peak strain in the AM-ACL than does a corresponding external tibial torque. PMID:22025178
Hussain, Sara J; Frey-Law, Laura
2016-01-01
The ankle is an important component of the human kinetic chain, and deficits in ankle strength can negatively impact functional tasks such as balance and gait. While peak torque is influenced by joint angle and movement velocity, ankle strength is typically reported for a single angle or movement speed. To better identify deficits and track recovery of ankle strength after injury or surgical intervention, ankle strength across a range of movement velocities and joint angles in healthy adults is needed. Thus, the primary goals of this study were to generate a database of strength values and 3-dimensional strength surface models for plantarflexion (PF) and dorsiflexion (DF) ankle strength in healthy men and women. Secondary goals were to develop a means to estimate ankle strength percentiles as well as examine predictors of maximal ankle strength in healthy adults. Using an isokinetic dynamometer, we tested PF and DF peak torques at five joint angles (-10° [DF], 0° [neutral], 10° [PF], 20° [PF] and 30° [PF]) and six velocities (0°/s, 30°/s, 60°/s, 90°/s, 120°/s and 180°/s) in 53 healthy adults. These data were used to generate 3D plots, or "strength surfaces", for males and females for each direction; surfaces were fit using a logistic equation. We also tested predictors of ankle strength, including height, weight, sex, and self-reported physical activity levels. Torque-velocity and torque-angle relationships at the ankle interact, indicating that these relationships are interdependent and best modeled using 3D surfaces. Sex was the strongest predictor of ankle strength over height, weight, and self-reported physical activity levels. 79 to 97 % of the variance in mean peak torque was explained by joint angle and movement velocity using logistic equations, for men and women and PF and DF directions separately. The 3D strength data and surface models provide a more comprehensive dataset of ankle strength in healthy adults than previously reported. These models may allow researchers and clinicians to quantify ankle strength deficits and track recovery in patient populations, using angle- and velocity-specific ankle strength values and/or strength percentiles from healthy adults.
Klos, Kajetan; Windolf, Markus; Schwieger, Karsten; Kuhn, Philipp; Hänni, Markus; Gueorguiev, Boyko; Hofmann, Gunther O; Mückley, Thomas
2009-12-01
Bone strength is currently measured with indirect techniques. We investigated the use of an intraoperative mechanical measurement for local bone strength determination and prediction of intramedullary-nail fusion failure. We investigated whether intraoperative local bone strength determination may be useful to the surgeon in predicting intramedullary nail hindfoot fusion performance. In seven human specimens, bone mineral density (BMD) was determined with qCT. A device (DensiProbe) specially devised for nailed tibiotalocalcaneal arthrodesis (TTCA) was inserted at the intended calcaneal screw sites of an intramedullary nail, and the cancellous break-away torque was measured. The constructs were then cyclically loaded to failure in dorsiflexion-plantarfexion. The BMD range was wide (42.8 to 185.9 mg HA/cm(3)). The proximal-screw site peak torque was 0.47 to 1.61 Nm; distal-screw site peak torque was 0.24 to 1.06 Nm. The number of cycles to failure correlated with peak torque both proximally (p = 0.021; r(2) = 0.69) and distally (p = 0.001; r(2) = 0.92). Proximally, peak torque did not correlate with BMD (p = 0.060; r(2) = 0.54); distally, it correlated significantly (p = 0.003; r(2) = 0.86). DensiProbe measurements can be used in the hindfoot to assess bone strength. In this study, specimens that failed early could be identified. However, in clinical practice fusion failure is multifactorial in origin, and failure prediction cannot be based upon peak torque measurements alone. The technique described here may be of use to give an intraoperative decision aid to predict intramedullary nail hindfoot fusion performance.
Large spin-orbit torques in Pt/Co-Ni/W heterostructures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yu, Jiawei; Qiu, Xuepeng; Legrand, William
2016-07-25
The spin orbit torques (SOTs) in perpendicularly magnetized Co-Ni multilayers sandwiched between two heavy metals (HM) have been studied. By exploring various HM materials, we show an efficient enhancement or cancellation of the total SOT, depending on the combination of the two HM materials. The maximum SOT effective field is obtained in Pt/Co-Ni/W heterostructures. We also model our double HM system and show that the effective spin Hall angle has a peak value at certain HM thicknesses. Measuring the SOT in Pt/Co-Ni/W for various W thicknesses confirms an effective spin Hall angle up to 0.45 in our double HM system.
Aerobic power and peak power of elite America's Cup sailors.
Neville, Vernon; Pain, Matthew T G; Folland, Jonathan P
2009-05-01
Big-boat yacht racing is one of the only able bodied sporting activities where standing arm-cranking ('grinding') is the primary physical activity. However, the physiological capabilities of elite sailors for standing arm-cranking have been largely unreported. The purpose of the study was to assess aerobic parameters, VO(2peak) and onset of blood lactate (OBLA), and anaerobic performance, torque-crank velocity and power-crank velocity relationships and therefore peak power (P (max)) and optimum crank-velocity (omega(opt)), of America's Cup sailors during standing arm-cranking. Thirty-three elite professional sailors performed a step test to exhaustion, and a subset of ten grinders performed maximal 7 s isokinetic sprints at different crank velocities, using a standing arm-crank ergometer. VO(2peak) was 4.7 +/- 0.5 L/min (range 3.6-5.5 L/min) at a power output of 332 +/- 44 W (range 235-425 W). OBLA occurred at a power output of 202 +/- 31 W (61% of W(max)) and VO(2) of 3.3 +/- 0.4 L/min (71% of VO(2peak)). The torque-crank velocity relationship was linear for all participants (r = 0.9 +/- 0.1). P (max) was 1,420 +/- 37 W (range 1,192-1,617 W), and omega(opt) was 125 +/- 6 rpm. These data are among the highest upper-body anaerobic and aerobic power values reported. The unique nature of these athletes, with their high fat-free mass and specific selection and training for standing arm cranking, likely accounts for the high values. The influence of crank velocity on peak power implies that power production during on-board 'grinding' may be optimised through the use of appropriate gear-ratios and the development of efficient gear change mechanisms.
On the energetics of the walking gait of a human operator using a passive exoskeleton apparatus
NASA Astrophysics Data System (ADS)
Lavrovskii, E. K.
2015-01-01
We study the energy expenditures and the peak values of control torques which a human operator must apply in the process of exoskeleton displacement for various types of regular, plane, and single-support gaits. The obtained results allow us to estimate the performance of the passive exoskeleton apparatus.
Lakie, M; Walsh, E G; Wright, G W
1984-01-01
The resonance of the relaxed wrist for flexion-extension movements in the horizontal plane has been investigated by using rhythmic torques generated by a printed motor. In the normal subject the resonant frequency of the wrist is ca. 2 Hz unless the torque is reduced below a certain critical value when the system is no longer linear and the resonant frequency rises. This critical torque level, and the damping are both less in women than men. The resonant frequency is uninfluenced by surgical anaesthesia. With added bias the increase of resonant frequency at low torques still occurs although the hand is now oscillating about a displaced mean position. It follows that the stiffening implied by this elevation of resonant frequency for small movements is neither the result of pre-stressing of the muscles nor of reflex activity. With velocity feed-back of appropriate polarity the system will oscillate spontaneously at its resonant frequency. If the peak driving torque is progressively reduced the resonant frequency increases abruptly, indicating that the system has stiffened. Perturbations delivered to the wrist may reduce its stiffness. The postural system is thixotropic with a 'memory time' of 1-2 s. The resonant frequency is elevated in voluntary stiffening. PMID:6481624
Al-Otaibi, Hanan N
2016-11-01
To measure the difference between the intended torque and the achieved torque by the operator using the spring-style mechanical torque-limiting device (MTLD). Inexperienced and experienced clinicians used one spring-type MTLD to torque two abutment screws of each anterior and posterior implants, which were attached to two digital torque meters through a jaw model. The jaw model was part of a preclinical bench manikin attached to a dental chair. The intended torque value was 35 N cm (recommended by manufacturer) and the technique of torquing was observed for all the participants (instantaneous and repeated). The mean torque value was calculated for each subject for the anterior and posterior implants independently; t-test was used to compare between the intended and achieved torque values and to compare between the experienced and inexperienced clinicians (p ≤ 0.05). Thirty-seven clinicians participated, with an overall mean torque value of 34.30 N cm. The mean torque value of the achieved torque (34.30 ± 4.13 N cm) was statistically significantly less than the intended torque (p = 0.041). The male clinicians produced more statistically significantly accurate torque value (34.54 ± 3.78 N cm) than the female clinicians (p = 0.034), and the experienced clinicians produced more accurate torque values (34.9 ± 5.13 N cm) than the inexperienced clinicians (p = 0.048). Within the limitation of this study, the use of MTLDs did not always produce consistent torque values and the technique by which the operators use the MTLD might affect the torque value.
Is muscular strength balance influenced by menstrual cycle in female soccer players?
Dos Santos Andrade, Marília; Mascarin, Naryana C; Foster, Roberta; de Jármy di Bella, Zsuzsanna I; Vancini, Rodrigo L; Barbosa de Lira, Claudio A
2017-06-01
Muscular strength imbalance is an important risk factor for ACL injury, but it is not clear the impact of menstrual cycle on muscular strength balance. Our aims were to compare muscular balance (hamstring-to-quadriceps peak torque strength balance ratio) between luteal and follicular phases and compare gender differences relative to strength balance to observe possible fluctuations in strength balance ratio. Thirty-eight soccer athletes (26 women and 12 men) took part in this study. Athletes participated in two identical isokinetic strength evaluations for both knee (non-dominant [ND] and dominant [D]). Peak torque for quadriceps and hamstring muscles were measured in concentric mode and hamstring-to-quadriceps peak torque strength balance ratio calculated. Women had significantly lower hamstring-to-quadriceps peak torque strength balance ratio during the follicular compared to luteal phase, for the ND limb (P=0.011). However, no differences, between luteal and follicular phases, were observed in the D limb. In men, no difference in strength balance ratios was found between the ND and D limbs. These data may be useful in prevention programs for knee (ACL) injuries among soccer female athletes.
Analysis of isokinetic muscle strength for sports physiotherapy research in Korean ssireum athletes
Noh, Ji-Woong; Park, Byoung-Sun; Kim, Mee-Young; Lee, Lim-Kyu; Yang, Seung-Min; Lee, Won-Deok; Shin, Yong-Sub; Kim, Ju-Hyun; Lee, Jeong-Uk; Kwak, Taek-Yong; Lee, Tae-Hyun; Kim, Ju-Young; Park, Jaehong; Kim, Junghwan
2015-01-01
[Purpose] The purpose of the present study was to elucidate the muscle conditions such as the isokinetic muscle of Korean ssireum athletes. [Subjects and Methods] This study enrolled 25 elite ssireum athletes. We measured body composition and peak torque at an angular speed at 60°/s using an isokinetic muscle strength dynamometer. [Results] The lean body mass of the left upper limb was significantly higher than that of the right upper limb. However, the lean body mass of the left lower limb was significantly lower than that of the right lower limb. The peak torque for left elbow flexion was significantly higher than that for right elbow flexion. Conversely, the peak torque for left elbow extension was significantly lower than that for right elbow extension. Furthermore, the peak torque for the left knee was significantly lower than that for the right knee for both flexion and extension. [Conclusion] The data from this study elucidate in part the muscle conditions of Korean ssireum athletes, which can be used to establish a reference for the scientific study of sports physiotherapy. PMID:26644679
Analysis of isokinetic muscle strength for sports physiotherapy research in Korean ssireum athletes.
Noh, Ji-Woong; Park, Byoung-Sun; Kim, Mee-Young; Lee, Lim-Kyu; Yang, Seung-Min; Lee, Won-Deok; Shin, Yong-Sub; Kim, Ju-Hyun; Lee, Jeong-Uk; Kwak, Taek-Yong; Lee, Tae-Hyun; Kim, Ju-Young; Park, Jaehong; Kim, Junghwan
2015-10-01
[Purpose] The purpose of the present study was to elucidate the muscle conditions such as the isokinetic muscle of Korean ssireum athletes. [Subjects and Methods] This study enrolled 25 elite ssireum athletes. We measured body composition and peak torque at an angular speed at 60°/s using an isokinetic muscle strength dynamometer. [Results] The lean body mass of the left upper limb was significantly higher than that of the right upper limb. However, the lean body mass of the left lower limb was significantly lower than that of the right lower limb. The peak torque for left elbow flexion was significantly higher than that for right elbow flexion. Conversely, the peak torque for left elbow extension was significantly lower than that for right elbow extension. Furthermore, the peak torque for the left knee was significantly lower than that for the right knee for both flexion and extension. [Conclusion] The data from this study elucidate in part the muscle conditions of Korean ssireum athletes, which can be used to establish a reference for the scientific study of sports physiotherapy.
Paddon-Jones, D; Muthalib, M; Jenkins, D
2000-03-01
This study examined markers of muscle damage following a repeated bout of maximal isokinetic eccentric exercise performed prior to full recovery from a previous bout. Twenty non-resistance trained volunteers were randomly assigned to a control (CON, n=10) or experimental (EXP, n=10) group. Both groups performed 36 maximal isokinetic eccentric contractions of the elbow flexors of the non-dominant arm (ECC1). The EXP group repeated the same eccentric exercise bout two days later (ECC2). Total work and peak eccentric torque were recorded during each set of ECC1 and ECC2. Isometric torque, delayed onset muscle soreness (DOMS), flexed elbow angle and plasma creatine kinase (CK) activity were measured prior to and immediately following ECC1 and ECC2. at 24h intervals for 7 days following ECC1 and finally on day 11. In both groups, all dependent variables changed significantly during the 2 days following ECC1. A further acute post-exercise impairment in isometric torque (30 +/- 5%) and flexed elbow angle (20 +/- 4%) was observed following ECC2 (p<0.05), despite EXP subjects producing uniformly lower work and peak eccentric torque values during ECC2 (p<0.05). No other significant differences between the CON and EXP groups were observed throughout the study (p>0.05). These findings suggest that when maximal isokinetic eccentric exercise is repeated two days after experiencing of contraction-induced muscle damage, the recovery time course is not significantly altered.
Eccentric Torque-Producing Capacity is Influenced by Muscle Length in Older Healthy Adults.
Melo, Ruth C; Takahashi, Anielle C M; Quitério, Robison J; Salvini, Tânia F; Catai, Aparecida M
2016-01-01
Considering the importance of muscle strength to functional capacity in the elderly, the study investigated the effects of age on isokinetic performance and torque production as a function of muscle length. Eleven younger (24.2 ± 2.9 years) and 16 older men (62.7 ± 2.5 years) were subjected to concentric and eccentric isokinetic knee extension/flexion at 60 and 120° · s(-1) through a functional range of motion. The older group presented lower peak torque (in newton-meters) than the young group for both isokinetic contraction types (age effect, p < 0.001). Peak torque deficits in the older group were near 30 and 29% for concentric and eccentric contraction, respectively. Concentric peak torque was lower at 120° · s(-1) than at 60° · s(-1) for both groups (angular velocity effect, p < 0.001). Eccentric knee extension torque was the only exercise tested that showed an interaction effect between age and muscle length (p < 0.001), which suggested different torque responses to the muscle length between groups. Compared with the young group, the eccentric knee extension torque was 22-56% lower in the older group, with the deficits being lower in the shortened muscle length (22-27%) and higher (33-56%) in the stretched muscle length. In older men, the production of eccentric knee strength seems to be dependent on the muscle length. At more stretched positions, older subjects lose the capacity to generate eccentric knee extension torque. More studies are needed to assess the mechanisms involved in eccentric strength preservation with aging and its relationship with muscle length.
Oh, Youkeun K; Kreinbrink, Jennifer L; Wojtys, Edward M; Ashton-Miller, James A
2012-04-01
Anterior cruciate ligament (ACL) injuries most frequently occur under the large loads associated with a unipedal jump landing involving a cutting or pivoting maneuver. We tested the hypotheses that internal tibial torque would increase the anteromedial (AM) bundle ACL relative strain and strain rate more than would the corresponding external tibial torque under the large impulsive loads associated with such landing maneuvers. Twelve cadaveric female knees [mean (SD) age: 65.0 (10.5) years] were tested. Pretensioned quadriceps, hamstring, and gastrocnemius muscle-tendon unit forces maintained an initial knee flexion angle of 15°. A compound impulsive test load (compression, flexion moment, and internal or external tibial torque) was applied to the distal tibia while recording the 3D knee loads and tibofemoral kinematics. AM-ACL relative strain was measured using a 3 mm DVRT. In this repeated measures experiment, the Wilcoxon signed-rank test was used to test the null hypotheses with p < 0.05 considered significant. The mean (±SD) peak AM-ACL relative strains were 5.4 ± 3.7% and 3.1 ± 2.8% under internal and external tibial torque, respectively. The corresponding mean (± SD) peak AM-ACL strain rates reached 254.4 ± 160.1%/s and 179.4 ± 109.9%/s, respectively. The hypotheses were supported in that the normalized mean peak AM-ACL relative strain and strain rate were 70 and 42% greater under internal than under external tibial torque, respectively (p = 0.023, p = 0.041). We conclude that internal tibial torque is a potent stressor of the ACL because it induces a considerably (70%) larger peak strain in the AM-ACL than does a corresponding external tibial torque. Copyright © 2011 Orthopaedic Research Society.
Gait biomechanics of skipping are substantially different than those of running.
McDonnell, Jessica; Willson, John D; Zwetsloot, Kevin A; Houmard, Joseph; DeVita, Paul
2017-11-07
The inherit injury risk associated with high-impact exercises calls for alternative ways to achieve the benefits of aerobic exercise while minimizing excessive stresses to body tissues. Skipping presents such an alternative, incorporating double support, flight, and single support phases. We used ground reaction forces (GRFs), lower extremity joint torques and powers to compare skipping and running in 20 healthy adults. The two consecutive skipping steps on each limb differed significantly from each other, and from running. Running had the longest step length, the highest peak vertical GRF, peak knee extensor torque, and peak knee negative and positive power and negative and positive work. Skipping had the greater cadence, peak horizontal GRF, peak hip and ankle extensor torques, peak ankle negative power and work, and peak ankle positive power. The second vs first skipping step had the shorter step length, higher cadence, peak horizontal GRF, peak ankle extensor torque, and peak ankle negative power, negative work, and positive power and positive work. The first skipping step utilized predominately net negative joint work (eccentric muscle action) while the second utilized predominately net positive joint work (concentric muscle action). The skipping data further highlight the persistence of net negative work performed at the knee and net positive work performed at the ankle across locomotion gaits. Evidence of step segregation was seen in distribution of the braking and propelling impulses and net work produced across the hip, knee, and ankle joints. Skipping was substantially different than running and was temporally and spatially asymmetrical with successive foot falls partitioned into a dominant function, either braking or propelling whereas running had a single, repeated step in which both braking and propelling actions were performed equally. Copyright © 2017 Elsevier Ltd. All rights reserved.
Effect of surface anodization on stability of orthodontic microimplant
Karmarker, Sanket; Yu, Wonjae
2012-01-01
Objective To determine the effect of surface anodization on the interfacial strength between an orthodontic microimplant (MI) and the rabbit tibial bone, particularly in the initial phase after placement. Methods A total of 36 MIs were driven into the tibias of 3 mature rabbits by using the self-drilling method and then removed after 6 weeks. Half the MIs were as-machined (n = 18; machined group), while the remaining had anodized surfaces (n = 18; anodized group). The peak insertion torque (PIT) and the peak removal torque (PRT) values were measured for the 2 groups of MIs. These values were then used to calculate the interfacial shear strength between the MI and cortical bone. Results There were no statistical differences in terms of PIT between the 2 groups. However, mean PRT was significantly greater for the anodized implants (3.79 ± 1.39 Ncm) than for the machined ones (2.05 ± 1.07 Ncm) (p < 0.01). The interfacial strengths, converted from PRT, were calculated at 10.6 MPa and 5.74 MPa for the anodized and machined group implants, respectively. Conclusions Anodization of orthodontic MIs may enhance their early-phase retention capability, thereby ensuring a more reliable source of absolute anchorage. PMID:23112925
Linear modeling of human hand-arm dynamics relevant to right-angle torque tool interaction.
Ay, Haluk; Sommerich, Carolyn M; Luscher, Anthony F
2013-10-01
A new protocol was evaluated for identification of stiffness, mass, and damping parameters employing a linear model for human hand-arm dynamics relevant to right-angle torque tool use. Powered torque tools are widely used to tighten fasteners in manufacturing industries. While these tools increase accuracy and efficiency of tightening processes, operators are repetitively exposed to impulsive forces, posing risk of upper extremity musculoskeletal injury. A novel testing apparatus was developed that closely mimics biomechanical exposure in torque tool operation. Forty experienced torque tool operators were tested with the apparatus to determine model parameters and validate the protocol for physical capacity assessment. A second-order hand-arm model with parameters extracted in the time domain met model accuracy criterion of 5% for time-to-peak displacement error in 93% of trials (vs. 75% for frequency domain). Average time-to-peak handle displacement and relative peak handle force errors were 0.69 ms and 0.21%, respectively. Model parameters were significantly affected by gender and working posture. Protocol and numerical calculation procedures provide an alternative method for assessing mechanical parameters relevant to right-angle torque tool use. The protocol more closely resembles tool use, and calculation procedures demonstrate better performance of parameter extraction using time domain system identification methods versus frequency domain. Potential future applications include parameter identification for in situ torque tool operation and equipment development for human hand-arm dynamics simulation under impulsive forces that could be used for assessing torque tools based on factors relevant to operator health (handle dynamics and hand-arm reaction force).
Properties of Isokinetic Fatigue at Various Movement Speeds in Adult Males.
ERIC Educational Resources Information Center
Clarke, David H.; Manning, James M.
1985-01-01
Eighteen male subjects, aged 20 to 28 years, engaged in three fatigue bouts using an isokinetic dynamometer to measure knee extension contractions. Peak torque varied inversely with movement speed, and the pattern of decrement was independent of speed. Time to peak torque did not change significantly across trials in isokinetic fatigue. (Author/MT)
Sex Comparisons for Relative Peak Torque and Electromyographic Mean Frequency during Fatigue
ERIC Educational Resources Information Center
Stock, Matt S.; Beck, Travis W.; DeFreitas, Jason M.; Ye, Xin
2013-01-01
Purpose: This study compared the relative peak torque and normalized electromyographic (EMG) mean frequency (MNF) responses during fatiguing isokinetic muscle actions for men versus women. Method: Twenty men M[subscript age] ± SD = 22 ± 2 years) and 20 women M[subscript age] ± SD = 22 ± 1 years) performed 50 maximal concentric isokinetic muscle…
Design of patient-specific gait modifications for knee osteoarthritis rehabilitation.
Fregly, Benjamin J; Reinbolt, Jeffrey A; Rooney, Kelly L; Mitchell, Kim H; Chmielewski, Terese L
2007-09-01
Abstract-Gait modification is a nonsurgical approach for reducing the external knee adduction torque in patients with knee osteoarthritis (OA). The magnitude of the first adduction torque peak in particular is strongly associated with knee OA progression. While toeing out has been shown to reduce the second peak, no clinically realistic gait modifications have been identified that effectively reduce both peaks simultaneously. This study predicts novel patient-specific gait modifications that achieve this goal without changing the foot path. The modified gait motion was designed for a single patient with knee OA using dynamic optimization of a patient-specific, full-body gait model. The cost function minimized the knee adduction torque subject to constraints limiting how much the new gait motion could deviate from the patient's normal gait motion. The optimizations predicted a "medial-thrust" gait pattern that reduced the first adduction torque peak between 32% and 54% and the second peak between 34% and 56%. The new motion involved three synergistic kinematic changes: slightly decreased pelvis obliquity, slightly increased leg flexion, and slightly increased pelvis axial rotation. After gait retraining, the patient achieved adduction torque reductions of 39% to 50% in the first peak and 37% to 55% in the second one. These reductions are comparable to those reported after high tibial osteotomy surgery. The associated kinematic changes were consistent with the predictions except for pelvis obliquity, which showed little change. This study demonstrates that it is feasible to design novel patient-specific gait modifications with potential clinical benefit using dynamic optimization of patient-specific, full-body gait models. Further investigation is needed to assess the extent to which similar gait modifications may be effective for other patients with knee OA.
NASA Astrophysics Data System (ADS)
Hirayama, Shigeyuki; Mitani, Seiji; Otani, YoshiChika; Kasai, Shinya
2018-01-01
We systematically investigated the spin-torque ferromagnetic resonance (ST-FMR) in permalloy/Pt bilayer thin films under bias direct currents. According to the conventional ST-FMR theory, the half widths of the resonant peaks in the spectra can be modulated by bias currents, which give a reliable value of the spin injection efficiency of the spin Hall effect. On the other hand, the symmetric components of the spectra show an unexpected strong bias current dependence, while the asymmetric components are free from the modulation. These findings suggest that some contributions are missing in the ST-FMR analysis of the ferromagnetic/nonmagnetic metal bilayer thin films.
Recommended placement torque when tightening an orthodontic mini-implant.
Motoyoshi, Mitsuru; Hirabayashi, Masayuki; Uemura, Miwa; Shimizu, Noriyoshi
2006-02-01
To determine an adequate placement torque for obtaining a better success rate of mini-implants that are screwed into the buccal alveolar bone of the posterior region as an anchor for orthodontic treatment, implant placement torque (IPT) was measured. The subjects were 41 orthodontic patients (124 implants), with an average age of 24.9 years (SD 6.5 years), who had surgery to place titanium mini-implants. The peak value of IPT was measured using a torque screwdriver. The success rate of the mini-implant anchor for 124 implants was 85.5%. The mean IPT ranged from 7.2 to 13.5 N cm, depending on the location of the implants. There was a significant difference in the IPT between maxilla and mandible. The IPT in the mandible was, unexpectedly, significantly higher in the failure group than in the success group. Therefore, a large IPT should not be used always. According to our calculations of the risk ratio for failure, to raise the success rate of 1.6-mm diameter mini-implants, the recommended IPT is within the range from 5 to 10 N cm.
Strength deficits of the shoulder complex during isokinetic testing in people with chronic stroke
Nascimento, Lucas R.; Teixeira-Salmela, Luci F.; Polese, Janaine C.; Ada, Louise; Faria, Christina D. C. M.; Laurentino, Glória E. C.
2014-01-01
OBJECTIVES: To examine the strength deficits of the shoulder complex after stroke and to characterize the pattern of weakness according to type of movement and type of isokinetic parameter. METHOD: Twelve chronic stroke survivors and 12 age-matched healthy controls had their shoulder strength measured using a Biodex isokinetic dynamometer. Concentric measures of peak torque and work during shoulder movements were obtained in random order at speeds of 60°/s for both groups and sides. Type of movement was defined as scapulothoracic (protraction and retraction), glenohumeral (shoulder internal and external rotation) or combined (shoulder flexion and extension). Type of isokinetic parameter was defined as maximum (peak torque) or sustained (work). Strength deficits were calculated using the control group as reference. RESULTS: The average strength deficit for the paretic upper limb was 52% for peak torque and 56% for work. Decreases observed in the non-paretic shoulder were 21% and 22%, respectively. Strength deficit of the scapulothoracic muscles was similar to the glenohumeral muscles, with a mean difference of 6% (95% CI -5 to 17). Ability to sustain torque throughout a given range of motion was decreased as much as the peak torque, with a mean difference of 4% (95% CI -2 to 10). CONCLUSIONS: The findings suggest that people after stroke might benefit from strengthening exercises directed at the paretic scapulothoracic muscles in addition to exercises of arm elevation. Clinicians should also prescribe different exercises to improve the ability to generate force and the ability to sustain the torque during a specific range of motion. PMID:25003280
NASA Technical Reports Server (NTRS)
Montgomery, Raymond C.; Ghosh, Dave; Kenny, Sean
1991-01-01
This paper presents results of analytic and simulation studies to determine the effectiveness of torque-wheel actuators in suppressing the vibrations of two-link telerobotic arms with attached payloads. The simulations use a planar generic model of a two-link arm with a torque wheel at the free end. Parameters of the arm model are selected to be representative of a large space-based robotic arm of the same class as the Space Shuttle Remote Manipulator, whereas parameters of the torque wheel are selected to be similar to those of the Mini-Mast facility at the Langley Research Center. Results show that this class of torque-wheel can produce an oscillation of 2.5 cm peak-to-peak in the end point of the arm and that the wheel produces significantly less overshoot when the arm is issued an abrupt stop command from the telerobotic input station.
Hsu, Chao-Jung; George, Steven Z; Chmielewski, Terese L
2016-12-01
Clinicians use the single-leg hop test to assess readiness for return to sports after knee injury. Few studies have reported the results of single-leg hop testing after meniscectomy. Additionally, the contributions of impairments in quadriceps strength and psychosocial factors to single-leg hop performance are unknown. To compare single-leg hop performance (distance and landing mechanics) between limbs and to examine the association of single-leg hop performance with quadriceps strength and psychosocial factors in patients with meniscectomy. Descriptive laboratory study. A total of 22 subjects who underwent meniscectomy for traumatic meniscal tears received either standard rehabilitation alone or with additional quadriceps strengthening. Testing was conducted immediately postrehabilitation and at 1 year postsurgery. A single-leg hop test was performed bilaterally, and hop distance was used to create a hop symmetry index. Landing mechanics (peak knee flexion angle, knee extension moment, and peak vertical ground-reaction force) were analyzed with a motion-capture system and a force plate. An isokinetic dynamometer (60 deg/s) assessed knee extensor peak torque and rate of torque development (RTD 0-200ms and RTD 0-peak torque ). Questionnaires assessed fear of reinjury (Tampa Scale for Kinesiophobia [TSK-11]) and self-efficacy (Knee Activity Self-Efficacy [KASE]). Rehabilitation groups did not significantly differ in single-leg hop performance; therefore, groups were combined for further analyses. The mean hop symmetry index was 88.6% and 98.9% at postrehabilitation and 1 year postsurgery, respectively. Compared with the nonsurgical limb, the surgical limb showed decreased peak knee flexion angle at postrehabilitation and decreased knee extension moment at 1 year postsurgery. The hop symmetry index was positively associated with peak torque, RTD 0-200ms , and the KASE score at postrehabilitation. Moreover, at postrehabilitation, the peak knee flexion angle was positively associated with peak torque and RTD 0-200ms , and the knee extension moment was positively associated with RTD 0-200ms . At 1 year postsurgery, peak knee flexion angle and knee extension moment were both positively associated with peak torque, RTD 0-200ms , and RTD 0-peak torque . Although the hop symmetry index could be considered satisfactory for returning to sports, asymmetries in landing mechanics still exist in the first year postmeniscectomy. Greater quadriceps strength was associated with greater single-leg hop distance and better landing mechanics at both postrehabilitation and 1 year postsurgery. Knee activity self-efficacy was the only psychosocial factor associated with single-leg hop performance and isolated to a positive association with single-leg hop distance at postrehabilitation. Rate of development is not typically measured in the clinic but can be an additional quadriceps measure to monitor for single-leg hop performance. Quadriceps strength and psychosocial factors appear to have separate influence on single-leg hop performance after meniscectomy, which has implications for developing appropriate interventions for optimal single-leg hop performance.
Hsu, Chao-Jung; George, Steven Z.; Chmielewski, Terese L.
2016-01-01
Background: Clinicians use the single-leg hop test to assess readiness for return to sports after knee injury. Few studies have reported the results of single-leg hop testing after meniscectomy. Additionally, the contributions of impairments in quadriceps strength and psychosocial factors to single-leg hop performance are unknown. Purpose: To compare single-leg hop performance (distance and landing mechanics) between limbs and to examine the association of single-leg hop performance with quadriceps strength and psychosocial factors in patients with meniscectomy. Study Design: Descriptive laboratory study. Methods: A total of 22 subjects who underwent meniscectomy for traumatic meniscal tears received either standard rehabilitation alone or with additional quadriceps strengthening. Testing was conducted immediately postrehabilitation and at 1 year postsurgery. A single-leg hop test was performed bilaterally, and hop distance was used to create a hop symmetry index. Landing mechanics (peak knee flexion angle, knee extension moment, and peak vertical ground-reaction force) were analyzed with a motion-capture system and a force plate. An isokinetic dynamometer (60 deg/s) assessed knee extensor peak torque and rate of torque development (RTD0-200ms and RTD0–peak torque). Questionnaires assessed fear of reinjury (Tampa Scale for Kinesiophobia [TSK-11]) and self-efficacy (Knee Activity Self-Efficacy [KASE]). Results: Rehabilitation groups did not significantly differ in single-leg hop performance; therefore, groups were combined for further analyses. The mean hop symmetry index was 88.6% and 98.9% at postrehabilitation and 1 year postsurgery, respectively. Compared with the nonsurgical limb, the surgical limb showed decreased peak knee flexion angle at postrehabilitation and decreased knee extension moment at 1 year postsurgery. The hop symmetry index was positively associated with peak torque, RTD0-200ms, and the KASE score at postrehabilitation. Moreover, at postrehabilitation, the peak knee flexion angle was positively associated with peak torque and RTD0-200ms, and the knee extension moment was positively associated with RTD0-200ms. At 1 year postsurgery, peak knee flexion angle and knee extension moment were both positively associated with peak torque, RTD0-200ms, and RTD0–peak torque. Conclusion: Although the hop symmetry index could be considered satisfactory for returning to sports, asymmetries in landing mechanics still exist in the first year postmeniscectomy. Greater quadriceps strength was associated with greater single-leg hop distance and better landing mechanics at both postrehabilitation and 1 year postsurgery. Knee activity self-efficacy was the only psychosocial factor associated with single-leg hop performance and isolated to a positive association with single-leg hop distance at postrehabilitation. Clinical Relevance: Rate of development is not typically measured in the clinic but can be an additional quadriceps measure to monitor for single-leg hop performance. Quadriceps strength and psychosocial factors appear to have separate influence on single-leg hop performance after meniscectomy, which has implications for developing appropriate interventions for optimal single-leg hop performance. PMID:28210647
Czaplicki, Adam; Jarocka, Marta; Walawski, Jacek
2015-01-01
The aim of this study was to evaluate the serial change of isokinetic muscle strength of the knees before and after anterior cruciate ligament reconstruction (ACLR) in physically active males and to estimate the time of return to full physical fitness. Extension and flexion torques were measured for the injured and healthy limbs at two angular velocities approximately 1.5 months before the surgery and 3, 6, and 12 months after ACLR. Significant differences (p ≤ 0.05) in peak knee extension and flexion torques, hamstring/quadriceps (H/Q) strength ratios, uninvolved/involved limb peak torque ratios, and the normalized work of these muscles between the four stages of rehabilitation were identified. Significant differences between extension peak torques for the injured and healthy limbs were also detected at all stages. The obtained results showed that 12 months of rehabilitation were insufficient for the involved knee joint to recover its strength to the level of strength of the uninvolved knee joint. The results helped to evaluate the progress of the rehabilitation and to implement necessary modifications optimizing the rehabilitation training program. The results of the study may also be used as referential data for physically active males of similar age. PMID:26646385
Immediate effects of whole body vibration on patellar tendon properties and knee extension torque.
Rieder, F; Wiesinger, H-P; Kösters, A; Müller, E; Seynnes, O R
2016-03-01
Reports about the immediate effects of whole body vibration (WBV) exposure upon torque production capacity are inconsistent. However, the changes in the torque-angle relationship observed by some authors after WBV may hinder the measurement of torque changes at a given angle. Acute changes in tendon mechanical properties do occur after certain types of exercise but this hypothesis has never been tested after a bout of WBV. The purpose of the present study was to investigate whether tendon compliance is altered immediately after WBV, effectively shifting the optimal angle of peak torque towards longer muscle length. Twenty-eight subjects were randomly assigned to either a WBV (n = 14) or a squatting control group (n = 14). Patellar tendon CSA, stiffness and Young's modulus and knee extension torque-angle relationship were measured using ultrasonography and dynamometry 1 day before and directly after the intervention. Tendon CSA was additionally measured 24 h after the intervention to check for possible delayed onset of swelling. The vibration intervention had no effects on patellar tendon CSA, stiffness and Young's modulus or the torque-angle relationship. Peak torque was produced at ~70° knee angle in both groups at pre- and post-test. Additionally, the knee extension torque globally remained unaffected with the exception of a small (-6%) reduction in isometric torque at a joint angle of 60°. The present results indicate that a single bout of vibration exposure does not substantially alter patellar tendon properties or the torque-angle relationship of knee extensors.
Test-retest reliability of cardinal plane isokinetic hip torque and EMG.
Claiborne, Tina L; Timmons, Mark K; Pincivero, Danny M
2009-10-01
The objective of the present study was to establish test-retest reliability of isokinetic hip torque and prime mover electromyogram (EMG) through the three cardinal planes of motion. Thirteen healthy young adults participated in two experimental sessions, separated by approximately one week. During each session, isokinetic hip torque was evaluated on the Biodex Isokinetic Dynamometer at a velocity of 60 deg/s. Subjects performed three maximal-effort concentric and eccentric contractions, separately, for right and left hip abduction/adduction, flexion/extension, and internal/external rotation. Surface EMGs were sampled from the gluteus maximus, gluteus medius, adductor, medial and lateral hamstring, and rectus femoris muscles during all contractions. Intraclass correlation coefficients (ICC - 2,1) and standard errors of measurement (SEM) were calculated for peak torque for each movement direction and contraction mode, while ICCs were only computed for the EMG data. Motions that demonstrated high torque reliability included concentric hip abduction (right and left), flexion (right and left), extension (right) and internal rotation (right and left), and eccentric hip abduction (left), adduction (left), flexion (right), and extension (right and left) (ICC range=0.81-0.91). Motions with moderate torque reliability included concentric hip adduction (right), extension (left), internal rotation (left), and external rotation (right), and eccentric hip abduction and adduction (right), flexion (left), internal rotation (right and left), and external rotation (right and left) (ICC range=0.49-0.79). The majority of the EMG sampled muscles (n=12 and n=11 for concentric and eccentric contractions, respectively) demonstrated high reliability (ICC=0.81-0.95). Instances of low, or unacceptable, EMG reliability values occurred for the medial hamstring muscle of the left leg (both contraction modes) and the adductor muscle of the right leg during eccentric internal rotation. The major finding revealed high and moderate levels of between-day reliability of isokinetic hip peak torque and prime mover EMG. It is recommended that the day-to-day variability estimates concomitant with acceptable levels of reliability be considered when attempting to objectify intervention effects on hip muscle performance.
Sensorimotor adaptations to microgravity in humans.
Edgerton, V R; McCall, G E; Hodgson, J A; Gotto, J; Goulet, C; Fleischmann, K; Roy, R R
2001-09-01
Motor function is altered by microgravity, but little detail is available as to what these changes are and how changes in the individual components of the sensorimotor system affect the control of movement. Further, there is little information on whether the changes in motor performance reflect immediate or chronic adaptations to changing gravitational environments. To determine the effects of microgravity on the neural control properties of selected motor pools, four male astronauts from the NASA STS-78 mission performed motor tasks requiring the maintenance of either ankle dorsiflexor or plantarflexor torque. Torques of 10 or 50% of a maximal voluntary contraction (MVC) were requested of the subjects during 10 degrees peak-to-peak sinusoidal movements at 0.5 Hz. When 10% MVC of the plantarflexors was requested, the actual torques generated in-flight were similar to pre-flight values. Post-flight torques were higher than pre- and in-flight torques. The actual torques when 50% MVC was requested were higher in- and post-flight than pre-flight. Soleus (Sol) electromyographic (EMG) amplitudes during plantarflexion were higher in-flight than pre- or post-flight for both the 10 and 50% MVC tasks. No differences in medial gastrocnemius (MG) EMG amplitudes were observed for either the 10 or 50% MVC tasks. The EMG amplitudes of the tibialis anterior (TA), an antagonist to plantarflexion, were higher in- and post-flight than pre-flight for the 50% MVC task. During the dorsiflexion tasks, the torques generated in both the 10 and 50% MVC tasks did not differ pre-, in- and post-flight. TA EMG amplitudes were significantly higher in- than pre-flight for both the 10 or 50% MVC tasks, and remained elevated post-flight for the 50% MVC test. Both the Sol and MG EMG amplitudes were significantly higher in-flight than either pre- or post-flight for both the 10 and 50% MVC tests. These data suggest that the most consistent response to space flight was an elevation in the level of contractions of agonists and antagonists when attempting to maintain constant torques at a given level of MVC. Also, the chronic levels of EMG activity in selected ankle flexor and extensor muscles during space flight and during routine activities on Earth were recorded. Compared with pre- and post-flight values, there was a marked increase in the total EMG activity of the TA and the Sol and no change in the MG EMG activity in-flight. These data indicate that space flight, as occurs on shuttle missions, is a model of elevated activation of both flexor and extensor muscles, probably reflecting the effects of programmed work schedules in flight rather than a direct effect of microgravity.
Sensorimotor adaptations to microgravity in humans
NASA Technical Reports Server (NTRS)
Edgerton, V. R.; McCall, G. E.; Hodgson, J. A.; Gotto, J.; Goulet, C.; Fleischmann, K.; Roy, R. R.
2001-01-01
Motor function is altered by microgravity, but little detail is available as to what these changes are and how changes in the individual components of the sensorimotor system affect the control of movement. Further, there is little information on whether the changes in motor performance reflect immediate or chronic adaptations to changing gravitational environments. To determine the effects of microgravity on the neural control properties of selected motor pools, four male astronauts from the NASA STS-78 mission performed motor tasks requiring the maintenance of either ankle dorsiflexor or plantarflexor torque. Torques of 10 or 50% of a maximal voluntary contraction (MVC) were requested of the subjects during 10 degrees peak-to-peak sinusoidal movements at 0.5 Hz. When 10% MVC of the plantarflexors was requested, the actual torques generated in-flight were similar to pre-flight values. Post-flight torques were higher than pre- and in-flight torques. The actual torques when 50% MVC was requested were higher in- and post-flight than pre-flight. Soleus (Sol) electromyographic (EMG) amplitudes during plantarflexion were higher in-flight than pre- or post-flight for both the 10 and 50% MVC tasks. No differences in medial gastrocnemius (MG) EMG amplitudes were observed for either the 10 or 50% MVC tasks. The EMG amplitudes of the tibialis anterior (TA), an antagonist to plantarflexion, were higher in- and post-flight than pre-flight for the 50% MVC task. During the dorsiflexion tasks, the torques generated in both the 10 and 50% MVC tasks did not differ pre-, in- and post-flight. TA EMG amplitudes were significantly higher in- than pre-flight for both the 10 or 50% MVC tasks, and remained elevated post-flight for the 50% MVC test. Both the Sol and MG EMG amplitudes were significantly higher in-flight than either pre- or post-flight for both the 10 and 50% MVC tests. These data suggest that the most consistent response to space flight was an elevation in the level of contractions of agonists and antagonists when attempting to maintain constant torques at a given level of MVC. Also, the chronic levels of EMG activity in selected ankle flexor and extensor muscles during space flight and during routine activities on Earth were recorded. Compared with pre- and post-flight values, there was a marked increase in the total EMG activity of the TA and the Sol and no change in the MG EMG activity in-flight. These data indicate that space flight, as occurs on shuttle missions, is a model of elevated activation of both flexor and extensor muscles, probably reflecting the effects of programmed work schedules in flight rather than a direct effect of microgravity.
Trisi, Paolo; De Benedittis, Simona; Perfetti, Giorgio; Berardi, Davide
2011-05-01
Protocols of immediate loading have been reported in several studies. It has also been demonstrated that the cause of failure of immediate loaded implants is due to the micromotion on the bone-implant interface induced by immediate loading. There should be a minimum gap between the implant and the peri-implant bone, without micromotions occurring above a definite threshold risk as they induce bone resorption and fibrosis around the implant. Measurement of the torque necessary to insert an implant in the bone is a parameter for measuring initial stability. The higher the implant insertion torque, the higher the initial stability attained. The aim of this study was to evaluate in vitro the correlation between the micromotion of cylindric screw implants ad modum Branemark and the insertion torque in bone of different densities. The test was carried out on 2 × 2 cm samples of fresh bovine bone of three different densities: hard (H), medium (M) and soft (S). One hundred and fifty hexa implants ad modum Branemark were used, 3.75 mm in diameter and 9 mm long. To screw in the implants, a customized manual key was used, controlled digitally to evaluate the peak insertion torques. Ten implants were prepared for each torque (20, 35, 45, 70 and 100 N/cm). The bone sample was then fixed on a loading device, which allowed evaluating the micromotion. On each sample, we applied a 25 N horizontal force. The results indicate that the peak insertion torque and the implant micromotion are statistically correlated, and statistically significant differences in H and M bone were found compared with S bone. In S bone, we noted a micromotion significantly higher than the risk threshold, and it was not possible to reach peak insertion torque above 35 N/cm. In H and M bone, the micromotion is below the threshold of all insertion torques. Increasing the peak insertion torque, we can reduce the extent of the micromotion between the implant and the bone when submitted to lateral forces in vitro. In soft bone, the micromotion was always high; hence, immediate loading of implants in low-density bone should be evaluated with care. © 2010 John Wiley & Sons A/S.
Isokinetic muscle performance of the hip and ankle muscles in women with fibromyalgia.
Yetişgin, Alparslan; Tiftik, Tülay; Kara, Murat; Karabay, İlkay; Akkuş, Selami; Ersöz, Murat
2016-06-01
To compare isokinetic muscle performances of a proximal (hip) and a distal (ankle) muscle of fibromyalgia syndrome (FMS) patients with those of age- and body mass index (BMI)-matched healthy subjects. Thirty female patients with FMS (mean age: 41.5 ± 6.7 years [range, 27-54]) and 30 age- (mean age: 40.6 ± 6.0 years [range, 27-54]) and BMI-matched female healthy controls were consecutively enrolled. Demographic and clinical characteristics of the subjects were recorded. Isokinetic measurements of hip and ankle flexion and extension at angular velocities of 60°/s and 180°/s, peak torques, flexor-extensor torque ratios, muscle fatigue resistance values and average power were obtained. Mean disease duration of FMS patients was 2.4 ± 1.9 years. Mean weight, height and BMI values were 70.4 ± 12.5 kg, 159.5 ± 6.0 cm and 27.7 ± 4.7 kg/m² (FMS patients) and 69.3 ± 10.1 kg, 161.7 ± 6.2 cm and 26.6 ± 4.3 kg/m² (control subjects), respectively (all P > 0.05). All isokinetic values were statistically decreased in the FMS group when compared with the control group, except for the peak torques at angular velocity of 180°/s on flexion of the hip and extension of the ankle and the total work and average power on extension of the ankle. We did not find any correlation between isokinetic values and disease related parameters of FMS patients. In the light of our results, we may conclude that muscle strength and muscle fatigue seem to decrease in FMS patients' both proximal and distal lower extremity muscles. © 2013 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.
Estigoni, Eduardo H.; Fornusek, Che; Hamzaid, Nur Azah; Hasnan, Nazirah; Smith, Richard M.; Davis, Glen M.
2014-01-01
This study investigated whether the relationship between muscle torque and m-waves remained constant after short recovery periods, between repeated intervals of isometric muscle contractions induced by functional electrical stimulation (FES). Eight subjects with spinal cord injury (SCI) were recruited for the study. All subjects had their quadriceps muscles group stimulated during three sessions of isometric contractions separated by 5 min of recovery. The evoked-electromyographic (eEMG) signals, as well as the produced torque, were synchronously acquired during the contractions and during short FES bursts applied during the recovery intervals. All analysed m-wave variables changed progressively throughout the three contractions, even though the same muscle torque was generated. The peak to peak amplitude (PtpA), and the m-wave area (Area) were significantly increased, while the time between the stimulus artefact and the positive peak (PosT) were substantially reduced when the muscles became fatigued. In addition, all m-wave variables recovered faster and to a greater extent than did torque after the recovery intervals. We concluded that rapid recovery intervals between FES-evoked exercise sessions can radically interfere in the use of m-waves as a proxy for torque estimation in individuals with SCI. This needs to be further investigated, in addition to seeking a better understanding of the mechanisms of muscle fatigue and recovery. PMID:25479324
Estigoni, Eduardo H; Fornusek, Che; Hamzaid, Nur Azah; Hasnan, Nazirah; Smith, Richard M; Davis, Glen M
2014-12-03
This study investigated whether the relationship between muscle torque and m-waves remained constant after short recovery periods, between repeated intervals of isometric muscle contractions induced by functional electrical stimulation (FES). Eight subjects with spinal cord injury (SCI) were recruited for the study. All subjects had their quadriceps muscles group stimulated during three sessions of isometric contractions separated by 5 min of recovery. The evoked-electromyographic (eEMG) signals, as well as the produced torque, were synchronously acquired during the contractions and during short FES bursts applied during the recovery intervals. All analysed m-wave variables changed progressively throughout the three contractions, even though the same muscle torque was generated. The peak to peak amplitude (PtpA), and the m-wave area (Area) were significantly increased, while the time between the stimulus artefact and the positive peak (PosT) were substantially reduced when the muscles became fatigued. In addition, all m-wave variables recovered faster and to a greater extent than did torque after the recovery intervals. We concluded that rapid recovery intervals between FES-evoked exercise sessions can radically interfere in the use of m-waves as a proxy for torque estimation in individuals with SCI. This needs to be further investigated, in addition to seeking a better understanding of the mechanisms of muscle fatigue and recovery.
Thompson, Brennan J; Stock, Matt S; Shields, JoCarol E; Luera, Micheal J; Munayer, Ibrahim K; Mota, Jacob A; Carrillo, Elias C; Olinghouse, Kendra D
2015-01-01
The primary purpose of this study was to examine the effects of 10 weeks of barbell deadlift training on rapid torque characteristics of the knee extensors and flexors. A secondary aim was to analyze the relationships between training-induced changes in rapid torque and vertical jump performance. Fifty-four subjects (age, mean ± SD = 23 ± 3 years) were randomly assigned to a control (n = 20) or training group (n = 34). Subjects in the training group performed supervised deadlift training twice per week for 10 weeks. All subjects performed isometric strength testing of the knee extensors and flexors and vertical jumps before and after the intervention. Torque-time curves were used to calculate rate of torque development (RTD) values at peak and at 50 and 200 milliseconds from torque onset. Barbell deadlift training induced significant pre- to post-increases of 18.8-49.0% for all rapid torque variables (p < 0.01). Vertical jump height increased from 46.0 ± 11.3 to 49.4 ± 11.3 cm (7.4%; p < 0.01), and these changes were positively correlated with improvements in RTD for the knee flexors (r = 0.30-0.37, p < 0.01-0.03). These findings showed that a 10-week barbell deadlift training program was effective at enhancing rapid torque capacities in both the knee extensors and flexors. Changes in rapid torque were associated with improvements in vertical jump height, suggesting a transfer of adaptations from deadlift training to an explosive, performance-based task. Professionals may use these findings when attempting to design effective, time-efficient resistance training programs to improve explosive strength capacities in novices.
Bates, Nathaniel A; Nesbitt, Rebecca J; Shearn, Jason T; Myer, Gregory D; Hewett, Timothy E
2016-07-01
Tibial slope angle is a nonmodifiable risk factor for anterior cruciate ligament (ACL) injury. However, the mechanical role of varying tibial slopes during athletic tasks has yet to be clinically quantified. To examine the influence of posterior tibial slope on knee joint loading during controlled, in vitro simulation of the knee joint articulations during athletic tasks. Descriptive laboratory study. A 6 degree of freedom robotic manipulator positionally maneuvered cadaveric knee joints from 12 unique specimens with varying tibial slopes (range, -7.7° to 7.7°) through drop vertical jump and sidestep cutting tasks that were derived from 3-dimensional in vivo motion recordings. Internal knee joint torques and forces were recorded throughout simulation and were linearly correlated with tibial slope. The mean (±SD) posterior tibial slope angle was 2.2° ± 4.3° in the lateral compartment and 2.3° ± 3.3° in the medial compartment. For simulated drop vertical jumps, lateral compartment tibial slope angle expressed moderate, direct correlations with peak internally generated knee adduction (r = 0.60-0.65), flexion (r = 0.64-0.66), lateral (r = 0.57-0.69), and external rotation torques (r = 0.47-0.72) as well as inverse correlations with peak abduction (r = -0.42 to -0.61) and internal rotation torques (r = -0.39 to -0.79). Only frontal plane torques were correlated during sidestep cutting simulations. For simulated drop vertical jumps, medial compartment tibial slope angle expressed moderate, direct correlations with peak internally generated knee flexion torque (r = 0.64-0.69) and lateral knee force (r = 0.55-0.74) as well as inverse correlations with peak external torque (r = -0.34 to -0.67) and medial knee force (r = -0.58 to -0.59). These moderate correlations were also present during simulated sidestep cutting. The investigation supported the theory that increased posterior tibial slope would lead to greater magnitude knee joint moments, specifically, internally generated knee adduction and flexion torques. The knee torques that positively correlated with increased tibial slope angle in this investigation are associated with heightened risk of ACL injury. Therefore, the present data indicated that a higher posterior tibial slope is correlated to increased knee loads that are associated with heightened risk of ACL injury. © 2016 The Author(s).
Design of a lightweight, tethered, torque-controlled knee exoskeleton.
Witte, Kirby Ann; Fatschel, Andreas M; Collins, Steven H
2017-07-01
Lower-limb exoskeletons show promise for improving gait rehabilitation for those with chronic gait abnormalities due to injury, stroke or other illness. We designed and built a tethered knee exoskeleton with a strong lightweight frame and comfortable, four-point contact with the leg. The device is structurally compliant in select directions, instrumented to measure joint angle and applied torque, and is lightweight (0.76 kg). The exoskeleton is actuated by two off-board motors. Closed loop torque control is achieved using classical proportional feedback control with damping injection in conjunction with iterative learning. We tested torque measurement accuracy and found root mean squared (RMS) error of 0.8 Nm with a max load of 62.2 Nm. Bandwidth was measured to be phase limited at 45 Hz when tested on a rigid test stand and 23 Hz when tested on a person's leg. During bandwidth tests peak extension torques were measured up to 50 Nm. Torque tracking was tested during walking on a treadmill at 1.25 m/s with peak flexion torques of 30 Nm. RMS torque tracking error averaged over a hundred steps was 0.91 Nm. We intend to use this knee exoskeleton to investigate robotic assistance strategies to improve gait rehabilitation and enhance human athletic ability.
Park, Jihong; Hopkins, J Ty
2013-01-01
A ratio between the torque generated by maximal voluntary isometric contraction (MVIC) and exogenous electrical stimulus, central activation ratio (CAR), has been widely used to assess quadriceps function. To date, no data exist regarding between-session reliability of this measurement. Thirteen neurologically sound volunteers underwent three testing sessions (three trials per session) with 48 hours between-session. Subjects performed MVICs of the quadriceps with the knee locked at 90° flexion and the hip at 85°. Once the MVIC reached a plateau, an electrical stimulation from superimposed burst technique (SIB: 125 V with peak output current 450 mA) was manually delivered and transmitted directly to the quadriceps via stimulating electrodes. CAR was calculated by using the following equation: CAR = MVIC torque/MVIC + SIB torque. Intraclass correlation coefficients (ICC) were calculated within- (ICC((2,1))) and between-session (ICC((2,k))) for MVIC torques and CAR values. Our data show that quadriceps MVIC and CAR are very reliable both within- (ICC((2,1)) = 0.99 for MVIC; 0.94 for CAR) and between-measurement sessions (ICC((2,k)) = 0.92 for MVIC; 0.86 for CAR) in healthy young adults. For clinical research, more data of the patients with pathological conditions are required to ensure reproducibility of calculation of CAR.
McKinlay, Brandon John; Wallace, Phillip J; Dotan, Raffy; Long, Devon; Tokuno, Craig; Gabriel, David A; Falk, Bareket
2017-09-01
In explosive contractions, neural activation is a major factor in determining the rate of torque development, while the latter is an important determinant of jump performance. However, the contribution of neuromuscular activation and rate of torque development to jump performance in children and youth is unclear. The purpose of this study was to examine the relationships between the rate of neuromuscular activation, peak torque, rate of torque development, and jump performance in young male athletes. Forty-one 12.5 ± 0.5-year-old male soccer players completed explosive, unilateral isometric and dynamic (240°/s) knee extensions (Biodex System III), as well as countermovement-, squat-, and drop-jumps. Peak torque (pT), peak rate of torque development (pRTD), and rate of vastus lateralis activation (Q 30 ) during the isometric and dynamic contractions were examined in relation to attained jump heights. Isometric pT and pRTD were strongly correlated (r = 0.71) but not related to jump performance. Dynamic pT and pRTD, normalized to body mass, were significantly related to jump height in all 3 jumps (r = 0.38-0.66, p < 0.05). Dynamic normalized, but not absolute pRTD, was significantly related to Q 30 (r = 0.35, p < 0.05). In young soccer players, neuromuscular activation and rate of torque development in dynamic contractions are related to jump performance, while isometric contractions are not. These findings have implications in the choice of training and assessment methods for young athletes.
Pontaga, Inese; Zidens, Janis
2014-01-01
The aim of the investigation was to: 1) compare shoulder external/internal rotator muscles’ peak torques and average power values and their ratios in the dominant and non-dominant arm; 2) determine correlations between shoulder rotator muscles’ peak torques, average power and ball-throwing speed in handball players. Fourteen 14 to 15-year-old male athletes with injury-free shoulders participated in the study (body height: 176 ± 7 cm, body mass 63 ± 9 kg). The tests were carried out by an isokinetic dynamometer system in the shoulder internal and external rotation movements at angular velocities of 60°/s, 90°/s and 240°/s during concentric contractions. The eccentric external– concentric internal rotator muscle contractions were performed at the velocity of 90°/s. The player threw a ball at maximal speed keeping both feet on the floor. The speed was recorded with reflected light rays. Training in handball does not cause significant side asymmetry in shoulder external/internal rotator muscle peak torques or the average power ratio. Positive correlations between isokinetic characteristics of the shoulder internal and external rotator muscles and ball-throwing speed were determined. The power produced by internal rotator muscles during concentric contractions after eccentric contractions of external rotator muscles was significantly greater in the dominant than in the non-dominant arm. Thus, it may be concluded that the shoulder eccentric external/concentric internal rotator muscle power ratio is significantly greater than this ratio in the concentric contractions of these muscles. PMID:25414738
NASA Astrophysics Data System (ADS)
Zhou, Yu-Xuan; Wang, Hai-Peng; Bao, Xue-Liang; Lü, Xiao-Ying; Wang, Zhi-Gong
2016-02-01
Objective. Surface electromyography (sEMG) is often used as a control signal in neuromuscular electrical stimulation (NMES) systems to enhance the voluntary control and proprioceptive sensory feedback of paralyzed patients. Most sEMG-controlled NMES systems use the envelope of the sEMG signal to modulate the stimulation intensity (current amplitude or pulse width) with a constant frequency. The aims of this study were to develop a strategy that co-modulates frequency and pulse width based on features of the sEMG signal and to investigate the torque-reproduction performance and the level of fatigue resistance achieved with our strategy. Approach. We examined the relationships between wrist torque and two stimulation parameters (frequency and pulse width) and between wrist torque and two sEMG time-domain features (mean absolute value (MAV) and number of slope sign changes (NSS)) in eight healthy volunteers. By using wrist torque as an intermediate variable, customized and generalized transfer functions were constructed to convert the two features of the sEMG signal into the two stimulation parameters, thereby establishing a MAV/NSS dual-coding (MNDC) algorithm. Wrist torque reproduction performance was assessed by comparing the torque generated by the algorithms with that originally recorded during voluntary contractions. Muscle fatigue was assessed by measuring the decline percentage of the peak torque and by comparing the torque time integral of the response to test stimulation trains before and after fatigue sessions. Main Results. The MNDC approach could produce a wrist torque that closely matched the voluntary wrist torque. In addition, a smaller decay in the wrist torque was observed after the MNDC-coded fatigue stimulation was applied than after stimulation using pulse-width modulation alone. Significance. Compared with pulse-width modulation stimulation strategies that are based on sEMG detection, the MNDC strategy is more effective for both voluntary muscle force reproduction and muscle fatigue reduction.
What Strains the Anterior Cruciate Ligament During a Pivot Landing?
Oh, Youkeun K.; Lipps, David B.; Ashton-Miller, James A.; Wojtys, Edward M.
2015-01-01
Background The relative contributions of an axial tibial torque and frontal plane moment to anterior cruciate ligament (ACL) strain during pivot landings are unknown. Hypothesis The peak normalized relative strain in the anteromedial (AM) bundle of the ACL is affected by the direction of the axial tibial torque but not by the direction of the frontal plane moment applied concurrently during a simulated jump landing. Study Design Controlled and descriptive laboratory studies. Methods Fifteen adult male knees with pretensioned knee muscle-tendon unit forces were loaded under a simulated pivot landing test. Compression, flexion moment, internal or external tibial torque, and knee varus or valgus moment were simultaneously applied to the distal tibia while recording the 3D knee loads and tibiofemoral kinematics. The AM-ACL relative strain was measured using a 3-mm differential variable reluctance transducer. The results were analyzed using nonparametric Wilcoxon signed–rank tests. A 3D dynamic biomechanical knee model was developed using ADAMS and validated to help interpret the experimental results. Results The mean (SD) peak AM-ACL relative strain was 192% greater (P <.001) under the internal tibial torque combined with a knee varus or valgus moment (7.0% [3.9%] and 7.0% [4.1%], respectively) than under external tibial torque with the same moments (2.4% [2.5%] and 2.4% [3.2%], respectively). The knee valgus moment augmented the AM-ACL strain due to the slope of the tibial plateau inducing mechanical coupling (ie, internal tibial rotation and knee valgus moment); this augmentation occurred before medial knee joint space opening. Conclusion An internal tibial torque combined with a knee valgus moment is the worst-case ACL loading condition. However, it is the internal tibial torque that primarily causes large ACL strain. Clinical Relevance Limiting the maximum coefficient of friction between the shoe and playing surface should limit the peak internal tibial torque that can be applied to the knee during jump landings, thereby reducing peak ACL strain and the risk for noncontact injury. PMID:22223717
Correlation of Shoulder and Elbow Kinetics With Ball Velocity in Collegiate Baseball Pitchers.
Post, Eric G; Laudner, Kevin G; McLoda, Todd A; Wong, Regan; Meister, Keith
2015-06-01
Throwing a baseball is a dynamic and violent act that places large magnitudes of stress on the shoulder and elbow. Specific injuries at the elbow and glenohumeral joints have been linked to several kinetic variables throughout the throwing motion. However, very little research has directly examined the relationship between these kinetic variables and ball velocity. To examine the correlation of peak ball velocity with elbow-valgus torque, shoulder external-rotation torque, and shoulder-distraction force in a group of collegiate baseball pitchers. Cross-sectional study. Motion-analysis laboratory. Sixty-seven asymptomatic National Collegiate Athletic Association Division I baseball pitchers (age = 19.5 ± 1.2 years, height = 186.2 ± 5.7 cm, mass = 86.7 ± 7.0 kg; 48 right handed, 19 left handed). We measured peak ball velocity using a radar gun and shoulder and elbow kinetics of the throwing arm using 8 electronically synchronized, high-speed digital cameras. We placed 26 reflective markers on anatomical landmarks of each participant to track 3-dimensional coordinate data. The average data from the 3 highest-velocity fastballs thrown for strikes were used for data analysis. We calculated a Pearson correlation coefficient to determine the associations between ball velocity and peak elbow-valgus torque, shoulder-distraction force, and shoulder external-rotation torque (P < .05). A weak positive correlation was found between ball velocity and shoulder-distraction force (r = 0.257; 95% confidence interval [CI] = 0.02, 0.47; r(2) = 0.066; P = .018). However, no significant correlations were noted between ball velocity and elbow-valgus torque (r = 0.199; 95% CI = -0.043, 0.419; r(2) = 0.040; P = .053) or shoulder external-rotation torque (r = 0.097; 95% CI = -0.147, 0.329; r(2) = 0.009; P = .217). Although a weak positive correlation was present between ball velocity and shoulder-distraction force, no significant association was seen between ball velocity and elbow-valgus torque or shoulder external-rotation torque. Therefore, other factors, such as improper pitching mechanics, may contribute more to increases in joint kinetics than peak ball velocity.
Correlation of Shoulder and Elbow Kinetics With Ball Velocity in Collegiate Baseball Pitchers
Post, Eric G.; Laudner, Kevin G.; McLoda, Todd A.; Wong, Regan; Meister, Keith
2015-01-01
Context Throwing a baseball is a dynamic and violent act that places large magnitudes of stress on the shoulder and elbow. Specific injuries at the elbow and glenohumeral joints have been linked to several kinetic variables throughout the throwing motion. However, very little research has directly examined the relationship between these kinetic variables and ball velocity. Objective To examine the correlation of peak ball velocity with elbow-valgus torque, shoulder external-rotation torque, and shoulder-distraction force in a group of collegiate baseball pitchers. Design Cross-sectional study. Setting Motion-analysis laboratory. Patients or Other Participants Sixty-seven asymptomatic National Collegiate Athletic Association Division I baseball pitchers (age = 19.5 ± 1.2 years, height = 186.2 ± 5.7 cm, mass = 86.7 ± 7.0 kg; 48 right handed, 19 left handed). Main Outcome Measure(s) We measured peak ball velocity using a radar gun and shoulder and elbow kinetics of the throwing arm using 8 electronically synchronized, high-speed digital cameras. We placed 26 reflective markers on anatomical landmarks of each participant to track 3-dimensional coordinate data. The average data from the 3 highest-velocity fastballs thrown for strikes were used for data analysis. We calculated a Pearson correlation coefficient to determine the associations between ball velocity and peak elbow-valgus torque, shoulder-distraction force, and shoulder external-rotation torque (P < .05). Results A weak positive correlation was found between ball velocity and shoulder-distraction force (r = 0.257; 95% confidence interval [CI] = 0.02, 0.47; r2 = 0.066; P = .018). However, no significant correlations were noted between ball velocity and elbow-valgus torque (r = 0.199; 95% CI = −0.043, 0.419; r2 = 0.040; P = .053) or shoulder external-rotation torque (r = 0.097; 95% CI = −0.147, 0.329; r2 = 0.009; P = .217). Conclusions Although a weak positive correlation was present between ball velocity and shoulder-distraction force, no significant association was seen between ball velocity and elbow-valgus torque or shoulder external-rotation torque. Therefore, other factors, such as improper pitching mechanics, may contribute more to increases in joint kinetics than peak ball velocity. PMID:25756790
Accuracy of electronic implant torque controllers following time in clinical service.
Mitrani, R; Nicholls, J I; Phillips, K M; Ma, T
2001-01-01
Tightening of the screws in implant-supported restorations has been reported to be problematic, in that if the applied torque is too low, screw loosening occurs. If the torque is too high, then screw fracture can take place. Thus, accuracy of the torque driver is of the utmost importance. This study evaluated 4 new electronic torque drivers (controls) and 10 test electronic torque drivers, which had been in clinical service for a minimum of 5 years. Torque values of the test drivers were measured and were compared with the control values using a 1-way analysis of variance. Torque delivery accuracy was measured using a technique that simulated the clinical situation. In vivo, the torque driver turns the screw until the selected tightening torque is reached. In this laboratory experiment, an implant, along with an attached abutment and abutment gold screw, was held firmly in a Tohnichi torque gauge. Calibration accuracy for the Tohnichi is +/- 3% of the scale value. During torque measurement, the gold screw turned a minimum of 180 degrees before contact was made between the screw and abutment. Three torque values (10, 20, and 32 N-cm) were evaluated, at both high- and low-speed settings. The recorded torque measurements indicated that the 10 test electronic torque drivers maintained a torque delivery accuracy equivalent to the 4 new (unused) units. Judging from the torque output values obtained from the 10 test units, the clinical use of the electronic torque driver suggests that accuracy did not change significantly over the 5-year period of clinical service.
Accuracy of mechanical torque-limiting devices for dental implants.
L'Homme-Langlois, Emilie; Yilmaz, Burak; Chien, Hua-Hong; McGlumphy, Edwin
2015-10-01
A common complication in implant dentistry is unintentional implant screw loosening. The critical factor in the prevention of screw loosening is the delivery of the appropriate target torque value. Mechanical torque-limiting devices (MTLDs) are the most frequently recommended devices by the implant manufacturers to deliver the target torque value to the screw. Two types of MTLDs are available: friction-style and spring-style. Limited information is available regarding the influence of device type on the accuracy of MTLDs. The purpose of this study was to determine and compare the accuracy of spring-style and friction-style MTLDs. Five MTLDs from 6 different dental implant manufacturers (Astra Tech/Dentsply, Zimmer Dental, Biohorizons, Biomet 3i, Straumann [ITI], and Nobel Biocare) (n=5 per manufacturer) were selected to determine their accuracy in delivering target torque values preset by their manufacturers. All torque-limiting devices were new and there were 3 manufacturers for the friction-style and 3 manufacturers for the spring-style. The procedure of target torque measurement was performed 10 times for each device and a digital torque gauge (Chatillon Model DFS2-R-ND; Ametek) was used to record the measurements. Statistical analysis used nonparametric tests to determine the accuracy of the MTLDs in delivering target torque values and Bonferroni post hoc tests were used to assess pairwise comparisons. Median absolute difference between delivered torque values and target torque values of friction-style and spring-style MTLDs were not significantly different (P>.05). Accuracy of Astra Tech and Zimmer Dental friction-style torque-limiting devices were significantly different than Biohorizons torque-limiting devices (P<.05). There is no difference between the accuracy of new friction-style MTLDs and new spring-style MTLDs. All MTLDs fell within ±10% of the target torque value. Astra Tech and Zimmer Dental friction-style torque-limiting devices were significantly more accurate than Biohorizons (C) torque-limiting devices (P<.05); however, all the torque-limiting devices fell within ±10% of the target torque value preset by the manufacturers. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Explosive sport training and torque kinetics in children.
Dotan, Raffy; Mitchell, Cameron J; Cohen, Rotem; Gabriel, David; Klentrou, Panagiota; Falk, Bareket
2013-07-01
A high rate of force development (RFD) is often more important than maximal force in daily and sports activities. In children, resistance training has been shown to increase maximal force. It is unclear whether, or to what extent, can children improve RFD and force kinetics. For this study, we compared strength and force kinetics of boy gymnasts with those of untrained boys and untrained men. Eight boy gymnasts (age, 9.5 ± 1.2 y), 20 untrained boys (age, 10.1 ± 1.3 y), and 20 untrained men (age, 22.9 ± 4.4 y) performed maximal, explosive, isometric elbow flexions (EF) and knee flexions (KF). Peak torque (maximal voluntary contraction (MVC)), elapsed times to 10%-100% MVC, peak rate of torque development (RTDpk), and other kinetics parameters were determined. When gymnasts were compared with untrained boys, size-normalized EF MVC was 11%-20% higher, RTDpk was 32% higher, and times to 30% and 80% MVC were 16% and 55% shorter, respectively (p < 0.05). No corresponding differences were observed in KF. Furthermore, although the normalized EF MVC was 28% lower in gymnasts than in men (p < 0.001), their torque kinetics parameters were similar. These findings highlight the specificity of gymnastics training, which markedly elevated the torque kinetics of young, prepubertal boys to adult levels, but only moderately affected peak torque. It is suggested that neurologic adaptations, such as enhanced firing and activation rates or increased type II motor-unit recruitment, as well as changes in musculotendinous stiffness, could explain these findings.
Pearson, Simon N.; Hume, Patria A.; Cronin, John; Slyfield, David
2016-01-01
Grinding is a key physical element in America’s Cup sailing. This study aimed to describe kinematics and muscle activation patterns in relation to torque applied in forward and backward grinding. Ten male America’s Cup sailors (33.6 ± 5.7 years, 97.9 ± 13.4 kg, 186.6 ± 7.4 cm) completed forward and backward grinding on a customised grinding ergometer. In forward grinding peak torque (77 Nm) occurred at 95° (0° = crank vertically up) on the downward section of the rotation at the end of shoulder flexion and elbow extension. Backward grinding torque peaked at 35° (69 Nm) following the pull action (shoulder extension, elbow flexion) across the top of the rotation. During forward grinding, relatively high levels of torque (>50 Nm) were maintained through the majority (72%) of the cycle, compared to 47% for backward grinding, with sections of low torque corresponding with low numbers of active muscles. Variation in torque was negatively associated with forward grinding performance (r = −0.60; 90% CI −0.88 to −0.02), but positively associated with backward performance (r = 0.48; CI = −0.15 to 0.83). Magnitude and distribution of torque generation differed according to grinding direction and presents an argument for divergent training methods to improve forward and backward grinding performance.
Influence of reverse torque values in abutments with or without internal hexagon indexes.
Cerutti-Kopplin, Daiane; Rodrigues Neto, Dimas João; Lins do Valle, Accácio; Pereira, Jefferson Ricardo
2014-10-01
The mechanical stability of the implant-abutment connection is of fundamental importance for successful implant-supported restorations. Therefore, understanding removal torque values is essential. The purpose of this study was to evaluate the reverse torque values of indexed and nonindexed abutments of the Morse Taper system. Twelve Morse taper implants with their respective abutments were divided into 2 groups (n=6): group NI, nonindexed abutments; and group IN, indexed abutments. Each abutment received a sequence of 2 consecutive torques for insertion (15 Ncm) at an interval of 10 minutes, and 1 reverse torque, all measured with a digital torque wrench. The Student t test with a 5% significance level was used to evaluate the data. Statistical analysis showed no significant difference in reverse torque values between nonindexed and indexed abutments (P=.57). When comparing insertion torque and reverse torque values between the groups, group NI presented a mean torque loosening percentage of 8% (P=.013), whereas group IN presented a loosening of 15.33% (P<.001). The use of indexed abutments for the Morse taper system presented similar biomechanical stability when compared with nonindexed abutments, both with a significant reduction in reverse torque values. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Al-Otaibi, Hanan Nejer; Akeel, Riyadh Fadul
2014-01-01
To determine the effect of increased torque of the abutment screw and retorquing after 10 minutes on implant-supported fixed prostheses. Two strain gauges (SGs) were attached to four implants stabilized on an acrylic resin mandible. Four implant-supported frameworks were constructed to represent passive fit (PF) and different amounts of misfit (MF1, MF2, and MF3). Vertical misfit was measured using a traveling microscope. Each framework was torqued to 35 Ncm (the manufacturer's recommendation) and 40 Ncm, and the preload was recorded immediately and again after retorquing 10 minutes later (torque stage). The smallest gap was observed under the PF framework. Three-way analysis of variance revealed significant effects of the framework, torque value, and torque stage on preload. The PF showed the highest mean preload under both torque values. An independent-sample t test between the torque values revealed a statistically significant difference only for MF1 and MF2. A dependent-sample t test of the torque stage revealed a statistically significant difference at a torque value of 35 Ncm under the PF and MF3 frameworks. Increasing the torque value beyond the manufacturer's recommended amount and retorquing of the screws at 10 minutes after the initial torque did not necessarily lead to a significant increase in preload in full-arch implant-supported fixed prostheses, particularly under non-passively fitting frameworks.
An Ankle-Foot Orthosis Powered by Artificial Pneumatic Muscles
Ferris, Daniel P.; Czerniecki, Joseph M.; Hannaford, Blake
2005-01-01
We developed a pneumatically powered orthosis for the human ankle joint. The orthosis consisted of a carbon fiber shell, hinge joint, and two artificial pneumatic muscles. One artificial pneumatic muscle provided plantar flexion torque and the second one provided dorsiflexion torque. Computer software adjusted air pressure in each artificial muscle independently so that artificial muscle force was proportional to rectified low-pass-filtered electromyography (EMG) amplitude (i.e., proportional myoelectric control). Tibialis anterior EMG activated the artificial dorsiflexor and soleus EMG activated the artificial plantar flexor. We collected joint kinematic and artificial muscle force data as one healthy participant walked on a treadmill with the orthosis. Peak plantar flexor torque provided by the orthosis was 70 Nm, and peak dorsiflexor torque provided by the orthosis was 38 Nm. The orthosis could be useful for basic science studies on human locomotion or possibly for gait rehabilitation after neurological injury. PMID:16082019
Neuromuscular performance in the hip joint of elderly fallers and non-fallers.
Morcelli, Mary Hellen; LaRoche, Dain Patrick; Crozara, Luciano Fernandes; Marques, Nise Ribeiro; Hallal, Camilla Zamfolini; Rossi, Denise Martineli; Gonçalves, Mauro; Navega, Marcelo Tavella
2016-06-01
Low strength and neuromuscular activation of the lower limbs have been associated with falls making it an important predictor of functional status in the elderly. To compare the rate of neuromuscular activation, rate of torque development, peak torque and reaction time between young and elderly fallers and non-fallers for hip flexion and extension. We evaluated 44 elderly people who were divided into two groups: elderly fallers (n = 20) and elderly non-fallers (n = 24); and 18 young people. The subjects performed three isometric hip flexion and extension contractions. Electromyography data were collected for the rectus femoris, gluteus maximus and biceps femoris muscles. The elderly had 49 % lower peak torque and 68 % lower rate of torque development for hip extension, 28 % lower rate of neuromuscular activation for gluteus maximus and 38 % lower rate of neuromuscular activation for biceps femoris than the young (p < 0.05). Furthermore, the elderly had 42 % lower peak torque and 62 % lower rate of torque development for hip flexion and 48 % lower rate of neuromuscular for rectus femoris than the young (p < 0.05). The elderly fallers showed consistent trend toward a lower rate of torque development than elderly non-fallers for hip extension at 50 ms (29 %, p = 0.298, d = 0.76) and 100 ms (26 %, p = 0.452, d = 0.68).The motor time was 30 % slower for gluteus maximus, 42 % slower for rectus femoris and 50 % slower for biceps femoris in the elderly than in the young. Impaired capacity of the elderly, especially fallers, may be explained by neural and morphological aspects of the muscles. The process of senescence affects the muscle function of the hip flexion and extension, and falls may be related to lower rate of torque development and slower motor time of biceps femoris.
Mackey, Dawn C; Robinovitch, Stephen N
2005-10-01
Fall risk depends on ability to maintain balance during daily activities, and on ability to recover balance following a perturbation such as a slip or trip. We examined whether similar neuromuscular variables govern these two domains of postural stability. We conducted experiments with 25 older women (mean age=78 yrs, SD=7 yrs). We acquired measures of postural steadiness during quiet stance (mean amplitude, velocity, and frequency of centre-of-pressure movement when standing with eyes open or closed, on a rigid or compliant surface). We also measured ability to recover balance using the ankle strategy after release from a forward leaning position (based on the maximum release angle where recovery was possible, and corresponding values of reaction time, rate of ankle torque generation, and peak ankle torque). We found that balance recovery variables were not strongly or consistently correlated with postural steadiness variables. The maximum release angle associated with only three of the sixteen postural steadiness variables (mean frequency in rigid, eyes open condition (r=0.36, P=.041), and mean amplitude (r=0.41, P=.038) and velocity (r=0.49, P=.015) in compliant, eyes closed condition). Reaction time and peak torque did not correlate with any steadiness variables, and rate of torque generation correlated moderately with the mean amplitude and velocity of the centre-of-pressure in the compliant, eyes closed condition (r=0.48-0.60). Our results indicate that postural steadiness during quiet stance is not predictive of ability to recover balance with the ankle strategy. Accordingly, balance assessment and fall prevention programs should individually target these two components of postural stability.
Reference values of hip abductor torque among youth athletes: Influence of age, sex and sports.
Bittencourt, Natália Franco Netto; Santos, Thiago Ribeiro Teles; Gonçalves, Gabriela Gomes Pavan; Coelho, Amanda Priscila; Gomes, Bárbara Gonçalves Braz de Magalhães; Mendonça, Luciana De Michelis; Fonseca, Sérgio Teixeira
2016-09-01
(1) To determine the reference values of hip abductor torque in youth athletes; (2) To investigate the influence of sex, age and sports on hip abductors torque. Cross-sectional. Sports clubs. 301 volleyball, basketball and futsal athletes between 10 and 19 years of age. Mean value of three maximal isometric hip abductor torques, evaluated using a hand-held dynamometer. The mean values of maximal isometric hip abductor torque ranged from 1.03 to 1.50 Nm/kg. The dominant hip abductor torque values were greater in 15-19 years old (1.41 ± 0.27 Nm/kg) than in 10-14 years old (1.12 ± 0.31 Nm/kg). In addition, the hip abductor torque values were smaller in basketball players (1.15 ± 0.31 Nm/kg) than futsal (1.34 ± 0.37 Nm/kg) and volleyball players (1.28 ± 0.25 Nm/kg). The comparison of hip abductor torque between futsal and volleyball players revealed no difference. The hip abductor torque values were greater in male volleyball athletes (1.28 ± 0.25 Nm/kg) than female volleyball athletes (1.13 ± 0.22 Nm/kg). This study established reference values for maximal isometric hip abductor torque in youth volleyball, basketball and futsal athletes. In addition, the results demonstrated that sex, age and sports influenced hip abductor torque. Copyright © 2015 Elsevier Ltd. All rights reserved.
The, Bertram; Brutty, Mike; Wang, Allan; Campbell, Peter T.; Halliday, Michael J. C.; Ackland, Timothy R.
2014-01-01
Introduction: The objective of this study is to evaluate the biomechanical function of the upper arm after arthroscopic long head of biceps (LHB) tenotomy at long-term follow-up. Materials and Methods: Twenty-five male subjects ranging from 30 to 63 years old were evaluated at a mean follow-up of 7.0 years after tenotomy. Bilateral isokinetic testing was performed to obtain peak torque values, as well as total work done throughout the full range of elbow flexion and supination. Results: Magnetic resonance imaging scans revealed nine unrecognized LHB ruptures in the contralateral arm, leaving 16 subjects to complete the testing protocol. The mean quickDASH score was 8.1 (standard error [SE] 2.5). The mean oxford elbow score was 97.9 (SE 1.6). The tenotomy arm recorded a decrease in peak flexion torque of 7.0% (confidence interval [CI] 1.2-12.8), and a decrease in the peak supination torque of 9.1% (CI 1.8-16.4) relative to the contralateral arm. The total work carried out through the full range of joint motion was reduced in elbow flexion by 5.1% (CI −1.3-11.4) and in forearm supination by 5.7% (CI-2.4-13.9). Discussion: Maximum strength in elbow flexion and forearm supination is significantly reduced compared with the contralateral arm. However, this impairment is partially compensated for by relatively greater strength sustained through the latter stages of joint motion. This results in comparable total work measurements between the tenotomised and contralateral side, potentially accounting for ongoing high levels of patient satisfaction and clinical function in the long term after LHB tenotomy. Level of Evidence IV: Case series without comparison group. PMID:25258498
Yapici, Aysegul; Findikoglu, Gulin; Dundar, Ugur
2016-04-01
The purpose of this study was to investigate the most important predictor isokinetic muscle strength determined by different angular velocities and contraction types (i.e. concentric and eccentric) for selected anaerobic power tests in volleyball players. Twenty male and ten female amateur volleyball players participated in this study. Selected anaerobic power tests included Wingate Anaerobic Test (WAnT), squat jump (SJ) and countermovement jump (CMJ). Peak torque values were obtained at 60, 120, 240˚/s for concentric contraction of quadriceps (Qconc) and Hamstring (Hconc) and at 60˚/s for eccentric contraction of quadriceps (Qecc) and Hconc. Moderate to good correlations (r:0.409 to r:0.887) were found between anaerobic tests and isokinetic data including peak torque and total work of both Hconc and Qconc at 60, 120, 240°/s and Qecc at 60°/s (P<0.05). Qconc measured at each of 60, 120, 240°/s was found to be the only significant predictor for anaerobic tests in linear regression models (P<0.05). Correlation coefficient s for Qconc increased with increasing velocity for each of the anaerobic tests. Correlation coefficient of Qconc was highest for CMJ followed by SJ and WAnT at the same angular velocity. As a distinctive feature, both Qecc and Hconc at 60˚/s were significantly predictors for CMJ and SJ. Qconc peak torque was the single significant predictor for WAnT, SJ and CMJ and strength of the relation increases with increasing angular velocity. However, both Qecc and Hconc were significant indicators for CMJ and SJ. Training with higher isokinetic angular velocities and with eccentric contraction is desirable in a training program that has a goal of improving anaerobic performance in volleyball players.
The, Bertram; Brutty, Mike; Wang, Allan; Campbell, Peter T; Halliday, Michael J C; Ackland, Timothy R
2014-07-01
The objective of this study is to evaluate the biomechanical function of the upper arm after arthroscopic long head of biceps (LHB) tenotomy at long-term follow-up. Twenty-five male subjects ranging from 30 to 63 years old were evaluated at a mean follow-up of 7.0 years after tenotomy. Bilateral isokinetic testing was performed to obtain peak torque values, as well as total work done throughout the full range of elbow flexion and supination. Magnetic resonance imaging scans revealed nine unrecognized LHB ruptures in the contralateral arm, leaving 16 subjects to complete the testing protocol. The mean quickDASH score was 8.1 (standard error [SE] 2.5). The mean oxford elbow score was 97.9 (SE 1.6). The tenotomy arm recorded a decrease in peak flexion torque of 7.0% (confidence interval [CI] 1.2-12.8), and a decrease in the peak supination torque of 9.1% (CI 1.8-16.4) relative to the contralateral arm. The total work carried out through the full range of joint motion was reduced in elbow flexion by 5.1% (CI -1.3-11.4) and in forearm supination by 5.7% (CI-2.4-13.9). Maximum strength in elbow flexion and forearm supination is significantly reduced compared with the contralateral arm. However, this impairment is partially compensated for by relatively greater strength sustained through the latter stages of joint motion. This results in comparable total work measurements between the tenotomised and contralateral side, potentially accounting for ongoing high levels of patient satisfaction and clinical function in the long term after LHB tenotomy. Case series without comparison group.
DEVELOPMENT OF AN ARMY STATIONARY AXLE TEST STAND FOR LUBRICANT EFFICIENCY EVALUATION-PART II
2017-01-13
value was estimated based on the engines maximum peak torque output, multiplied by the transmissions 1st gear ratio, high range transfer case ratio...efficiency test stand to allow for laboratory based investigation of Fuel Efficient Gear Oils (FEGO) and their impact on vehicle efficiency. Development...their impact on vehicle efficiency. The test stand was designed and developed with the following goals: • Provide a lower cost alternative for
The Accuracy of New and Aged Mechanical Torque Devices Employed in Five Dental Implant Systems.
Erdem, Mehmet Ali; Karatasli, Burcin; Dinçer Kose, Onur; Kose, Taha Emre; Çene, Erhan; Aydın Aya, Serhan; Cankaya, Abdulkadir Burak
2017-01-01
Friction-style and spring-style torque wrenches are used to tighten implant abutments and prosthetic screws. The mechanical stability of these torque wrenches is crucial for the implant-abutment connection. The purposes of this study were to assess the performance of five brands (Straumann, Zimmer, Implant KA, Bredent, and Biohorizons) of wrench and to evaluate possible changes in applied torque values of aged wrenches. Five new and aged wrenches that had been used approximately 250 times in a 1-year period were tested. The torque applied by friction- and spring-style wrenches was measured with a specially designed strain gauge indicator. Descriptive statistics, the one-sample t -test, and the independent-samples t -test were used to analyze values obtained from all torque wrenches. The accuracy of new and aged torque devices of all brands except Bredent differed significantly from the target values, but the mean values for aged and new wrenches did not differ significantly from each other ( p > 0.05). Values for the spring- and friction-type torque wrenches deviated from the target values by 11.6% and 10.2%, respectively. The accuracy of aged torque wrenches is adequate for prosthetic screw tightening, but that of new torque wrenches is unsatisfactory and must be examined carefully before delivery.
Do patients with diabetic neuropathy use a higher proportion of their maximum strength when walking?
Brown, Steven J; Handsaker, Joseph C; Bowling, Frank L; Maganaris, Costantinos N; Boulton, Andrew J M; Reeves, Neil D
2014-11-28
Diabetic patients have an altered gait strategy during walking and are known to be at high risk of falling, especially when diabetic peripheral neuropathy is present. This study investigated alterations to lower limb joint torques during walking and related these torques to maximum strength in an attempt to elucidate why diabetic patients are more likely to fall. 20 diabetic patients with moderate/severe peripheral neuropathy (DPN), 33 diabetic patients without peripheral neuropathy (DM), and 27 non-diabetic controls (Ctrl) underwent gait analysis using a motion analysis system and force plates to measure kinetic parameters. Lower limb peak joint torques and joint work done (energy expenditure) were calculated during walking. The ratio of peak joint torques and individual maximum joint strengths (measured on a dynamometer) was then calculated for 59 of the 80 participants to yield the ‘operating strength’ for those participants. During walking DM and DPN patients showed significantly reduced peak torques at the ankle and knee. Maximum joint strengths at the knee were significantly less in both DM and DPN groups than Ctrls, and for the DPN group at the ankle. Operating strengths were significantly higher at the ankle in the DPN group compared to the Ctrls. These findings show that diabetic patients walk with reduced lower limb joint torques; however due to a decrement in their maximum ability at the ankle and knee, their operating strengths are higher. This allows less reserve strength if responding to a perturbation in balance, potentially increasing their risk of falling.
The effects of a supportive knee brace on leg performance in healthy subjects.
Veldhuizen, J W; Koene, F M; Oostvogel, H J; von Thiel, T P; Verstappen, F T
1991-12-01
Eight healthy volunteers were fitted with a supportive knee brace (Push Brace 'Heavy') to one knee for a duration of four weeks wherein they were tested before, during and after the application to establish the effect of bracing on performance. The tests consisted of isokinetic strength measurement of knee flexion and extension, 60 meter dash, vertical jump height and a progressive horizontal treadmill test until exhaustion (Vmax) with determination of oxygen uptake, heart rate and plasma lactate concentration. Wearing the brace for one day, the performance indicators showed a decline compared with the test before application (base values). Sprint time was 4% longer (p less than 0.01) and Vmax 6% slower (p less than 0.01). Peak torque of knee flexion at 60 and 240 deg.sec-1 was 6% (p less than 0.05) respectively 9% (p less than 0.05) less. Peak extension torque at 60 deg.sec-1 was 9% less (p less than 0.05). While wearing the brace for four weeks, the test performances were practically identical to their base values. After removal of the brace, all test parameters were statistically similar to the base values. Heart rate at submaximal exercise levels was even lower (p less than 0.05). In conclusion, performance in sports with test-like exercise patterns is not affected by the brace tested. Bracing does not "weaken the knee" as it is widely believed in sports practice.
Abdel-Aziem, Amr Almaz; Soliman, Elsadat Saad; Abdelraouf, Osama Ragaa
2018-05-23
The aim of this study was to examine the effect of eccentric isotonic training on hamstring flexibility and eccentric and concentric isokinetic peak torque in trained and untrained subjects. Sixty healthy subjects (mean age: 21.66 ± 2.64) were divided into three equal groups, each with 20 voluntary participants. Two experimental groups (untrained and trained groups) participated in a hamstring eccentric isotonic strengthening program (five days/week) for a six-week period and one control group that was not involved in the training program. The passive knee extension range of motion and hamstring eccentric and concentric isokinetic peak torque were measured at angular velocities 60° and 120°/s for all groups before and after the training period. Two-way analysis of variance showed that there was a significant increase in the hamstring flexibility of the untrained and trained groups (25.65 ± 6.32°, 26.55 ± 5.99°, respectively), (p < 0.05) without a significant increase in the control group (31.55 ± 5.84°), (p > 0.05). Moreover, there was a significant increase in eccentric isokinetic peak torque of both the untrained and trained groups (127.25 ± 22.60Nm, 139.65 ± 19.15Nm, 125.40 ± 21.61Nm, 130.90 ± 18.71Nm, respectively), (p < 0.05) without a significant increase in the control group (109.15 ± 20.89Nm, 105.70 ± 21.31Nm, respectively), (p > 0.05) at both angular velocities. On the other hand, there was no significant increase in the concentric isokinetic peak torque of the three groups (92.50 ± 20.50Nm, 79.05 ± 18.95Nm, 92.20 ± 21.96Nm, 79.85 ± 18.97Nm, 100.45 ± 25.78Nm, 83.40 ± 23.73Nm, respectively), (p > 0.05) at both angular velocities. The change scores in the hamstring flexibility (06.25 ± 1.86°) and eccentric peak torque of the untrained group (16.60 ± 4.81Nm, 17.45 ± 5.40Nm, respectively) were significantly higher (p < 0.05) than those of the trained group (03.40 ± 1.14°, 9.90 ± 5.14Nm, 9.80 ± 7.57Nm, respectively), and the control group (00.90 ± 2.10°, 0.60 ± 2.93Nm, 1.40 ± 3.53Nm, respectively), at both angular velocities. Meanwhile, the change scores of the concentric peak torques of the three groups (1.15 ± 1.50Nm, -0.15 ± 2.16Nm, 1.35 ± 1.63Nm, 0.20 ± 2.95Nm, 0.60 ± 2.28Nm, -0.30 ± 2.25Nm) were statistically insignificant (p > 0.05). After a six-week period of eccentric isotonic training, the hamstring eccentric peak torque and flexibility of trained and untrained groups improved without changes in the concentric peak torque. Moreover, the improvement of untrained subjects was higher than trained subjects. These findings may be helpful in designing the hamstring rehabilitation program. Copyright © 2018 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.
Felicio, Diogo Carvalho; Pereira, Daniele Sirineu; Assumpção, Alexandra Miranda; de Jesus-Moraleida, Fabianna Resende; de Queiroz, Barbara Zille; da Silva, Juscelio Pereira; de Brito Rosa, Naysa Maciel; Dias, João Marcos Domingues; Pereira, Leani Souza Máximo
2014-01-01
To investigate the correlation between handgrip strength and performance of knee flexor and extensor muscles determined using an isokinetic dynamometer in community-dwelling elderly women. This was a cross-sectional study. Sample selection for the study was made by convenience, and 221 (71.07 ± 4.93 years) community-dwelling elderly women were included. Knee flexor and extensor muscle performance was measured using an isokinetic dynamometer Biodex System 3 Pro. The isokinetic variables chosen for analysis were peak torque, peak torque/bodyweight, total work/bodyweight, total work, average power, and agonist/antagonist ratio at the angular velocities of 60°/s and 180°/s. Assessment of handgrip strength was carried out using the Jamar dynamometer. Spearman's correlation coefficient was calculated to identify intervariable correlations. Only knee flexor peak torque (60°/s) and average power (60°/s), and knee extensor peak torque (180°/s) and total work (180°/s) were significantly (P < 0.05), yet poorly, correlated with handgrip strength (r < 0.30). The majority of analyses did not show any correlation between variables assessed by isokinetic dynamometer and handgrip dynamometer. Caution is required when generalizing handgrip strength as a predictor of global muscle strength in community-dwelling elderly women. © 2013 Japan Geriatrics Society.
Kinematic and kinetic analysis of the fouetté turn in classical ballet.
Imura, Akiko; Iino, Yoichi; Kojima, Takeji
2010-11-01
The fouetté turn in classical ballet dancing is a continuous turn with the whipping of the gesture leg and the arms and the bending and stretching of the supporting leg. The knowledge of the movement intensities of both legs for the turn would be favorable for the conditioning of the dancer's body. The purpose of this study was to estimate the intensities. The hypothesis of this study was that the intensities were higher in the supporting leg than in the gesture leg. The joint torques of both legs were determined in the turns performed by seven experienced female classical ballet dancers with inverse dynamics using three high-speed cine cameras and a force platform. The hip abductor torque, knee extensor and plantar flexor torques of the supporting leg were estimated to be exerted up to their maximum levels and the peaks of the torques were larger than the peaks of their matching torques of the gesture leg. Thus, the hypothesis was partly supported. Training of the supporting leg rather than the gesture leg would help ballet dancers perform many revolutions of the fouetté turn continuously.
Koontz, Alicia M; Cooper, Rory A; Boninger, Michael L; Yang, Yusheng; Impink, Bradley G; van der Woude, Lucas H V
2005-01-01
The objective of this study was to conduct a kinetic analysis of manual wheelchair propulsion during start-up on select indoor and outdoor surfaces. Eleven manual wheelchairs were fitted with a SMART(Wheel) and their users were asked to push on a course consisting of high- and low-pile carpet, indoor tile, interlocking concrete pavers, smooth level concrete, grass, hardwood flooring, and a sidewalk with a 5-degree grade. Peak resultant force, wheel torque, mechanical effective force, and maximum resultant force rate of rise were analyzed during start-up for each surface and normalized relative to their steady-state values on the smooth level concrete. Additional variables included peak velocity, distance traveled, and number of strokes in the first 5 s of the trial. We compared biomechanical data between surfaces using repeated-measures mixed models and paired comparisons with a Bonferroni adjustment. Applied resultant force (p = 0.0154), wheel torque (p < 0.0001), and mechanical effective force (p = 0.0047) were significantly different between surfaces. The kinetic values for grass, interlocking pavers, and ramp ascent were typically higher compared with tile, wood, smooth level concrete, and high- and low-pile carpet. Users were found to travel shorter distances up the ramp and across grass (p < 0.0025) and had a higher stroke count on the ramp (p = 0.0124). While peak velocity was not statistically different, average velocity was slower for the ramp and grass, which indicates greater wheelchair/user deceleration between strokes. The differences noted between surfaces highlight the importance of evaluating wheelchair propulsion ability over a range of surfaces.
Lee, Du-Hyeong; Kim, Yong-Gun; Lee, Jong-Ho; Hong, Sam-Pyo; Lim, Young-Jun; Lee, Kyu-Bok
2015-01-01
To determine the accuracy of applied torque of different implant controller and handpiece combinations by using an electronic torque gauge. Four combinations of the following devices were tested: Surgic XT controller (NSK), XIP10 controller (Saeshin), X-SG20L handpiece (NSK), CRB26LX handpiece (Saeshin). For five torque settings, 30 measurements were recorded at 30 revolutions per minute by using an electronic torque gauge fixed to jigs, and means were calculated. Applied torques were generally higher than the set torque of 10 and 20 Ncm and lower than the set values of 40 and 50 Ncm. The average torque deviations differed significantly among the combinations (P < .05). At 10 and 20 Ncm, the Surgic XT/X-SG20L combination yielded the closest value to the intended torque, followed by the XIP10/X-SG20L combination. At 30 Ncm, the XIP10/X-SG20L combination showed the nearest value. At 40 Ncm, the Surgic XT/X-SG20L, XIP10/CRB26LX, and XIP10/X-SG20L combinations showed deviations within 10%. At 50 Ncm, all the combinations showed lower applied torque than the set value. Large standard deviations were observed in the Surgic XT/CRB26LX (13.288) and Surgic XT/X-SG20L (7.858) combinations. Different combinations of implant controllers and handpieces do not generate significant variations in applied torque. The actual torque varies according to the torque setting. It is necessary to calibrate devices before use to reduce potentially problematic torque.
Toney, Megan E.; Chang, Young-Hui
2016-01-01
Human walking is a complex task, and we lack a complete understanding of how the neuromuscular system organizes its numerous muscles and joints to achieve consistent and efficient walking mechanics. Focused control of select influential task-level variables may simplify the higher-level control of steady state walking and reduce demand on the neuromuscular system. As trailing leg power generation and force application can affect the mechanical efficiency of step-to-step transitions, we investigated how joint torques are organized to control leg force and leg power during human walking. We tested whether timing of trailing leg force control corresponded with timing of peak leg power generation. We also applied a modified uncontrolled manifold analysis to test whether individual or coordinated joint torque strategies most contributed to leg force control. We found that leg force magnitude was adjusted from step-to-step to maintain consistent leg power generation. Leg force modulation was primarily determined by adjustments in the timing of peak ankle plantar-flexion torque, while knee torque was simultaneously covaried to dampen the effect of ankle torque on leg force. We propose a coordinated joint torque control strategy in which the trailing leg ankle acts as a motor to drive leg power production while trailing leg knee torque acts as a brake to refine leg power production. PMID:27334888
Serefoglu, Abdullah; Sekir, Ufuk; Gür, Hakan; Akova, Bedrettin
2017-03-01
The aim of this study was to investigate if static and dynamic stretching exercises of the knee muscles (quadriceps and hamstring muscles) have any effects on concentric and eccentric isokinetic peak torques and electromyographic amplitudes (EMG) of the antagonist muscles. Twenty healthy male athletes (age between 18-30 years) voluntarily participated in this study. All of the subjects visited the laboratory to complete the following intervention in a randomized order on 5 separate days; (a) non-stretching (control), (b) static stretching of the quadriceps muscles, (c) static stretching of the hamstring muscles, (d) dynamic stretching of the quadriceps muscles, and (e) dynamic stretching of the hamstring muscles. Static stretching exercises either for the quadriceps or the hamstring muscles were carried out at the standing and sitting positions. Subjects performed four successive repetitions of each stretching exercises for 30 seconds in both stretching positions. Similar to static stretching exercises two different stretching modes were designed for dynamic stretching exercises. Concentric and eccentric isokinetic peak torque for the non-stretched antagonist quadriceps or hamstring muscles at angular velocities of 60°/sec and 240°/sec and their concurrent electromyographic (EMG) activities were measured before and immediately after the intervention. Isokinetic peak torques of the non-stretched agonist hamstring and quadriceps muscles did not represent any significant (p > 0.05) differences following static and dynamic stretching of the antagonist quadriceps and hamstring muscles, respectively. Similarly, the EMG activities of the agonist muscles exhibited no significant alterations (p > 0.05) following both stretching exercises of the antagonist muscles. According to the results of the present study it is possible to state that antagonist stretching exercises either in the static or dynamic modes do not affect the isokinetic peak torques and the EMG activities of the non-stretched agonist quadriceps or hamstring muscles.
Isokinetic Leg Strength and Power in Elite Handball Players
González-Ravé, José M.; Juárez, Daniel; Rubio-Arias, Jacobo A.; Clemente-Suarez, Vicente J; Martinez-Valencia, María A; Abian-Vicen, Javier
2014-01-01
Isokinetic strength evaluation of the knee flexion and extension in concentric mode of contraction is an important part of the comprehensive evaluation of athletes. The aims of this study were to evaluate the isokinetic knee peak torque in both the extension and flexion movement in the dominant and non-dominant leg, and the relationship with jumping performance. Twelve elite male handball players from the top Spanish handball division voluntary participated in the study (age 27.68 ± 4.12 years; body mass 92.89 ± 12.34 kg; body height 1.90 ± 0.05 m). The knee extensor and flexor muscle peak torque of each leg were concentrically measured at 60º/s and 180º/s with an isokinetic dynamometer. The Squat Jump and Countermovement Jump were performed on a force platform to determine power and vertical jump height. Non-significant differences were observed between legs in the isokinetic knee extension (dominant= 2.91 ± 0.53 Nm/kg vs non-dominant = 2.70 ± 0.47 Nm/kg at 60º/s; dominant = 1.90 ± 0.31 Nm/kg vs non-dominant = 1.83 ± 0.29 Nm/kg at 180º/s) and flexion peak torques (dominant = 1.76 ± 0.29 Nm/kg vs non-dominant = 1.72 ± 0.39 Nm/kg at 60º/s; dominant = 1.30 ± 0.23 Nm/kg vs non-dominant = 1.27 ± 0.35 Nm/kg at 180º/s). Low and non-significant correlation coefficients were found between the isokinetic peak torques and vertical jumping performance (SJ = 31.21 ± 4.32 cm; CMJ = 35.89 ± 4.20 cm). Similar isokinetic strength was observed between the legs; therefore, no relationship was found between the isokinetic knee flexion and extension peak torques as well as vertical jumping performance in elite handball players. PMID:25114749
Isokinetic leg strength and power in elite handball players.
González-Ravé, José M; Juárez, Daniel; Rubio-Arias, Jacobo A; Clemente-Suarez, Vicente J; Martinez-Valencia, María A; Abian-Vicen, Javier
2014-06-28
Isokinetic strength evaluation of the knee flexion and extension in concentric mode of contraction is an important part of the comprehensive evaluation of athletes. The aims of this study were to evaluate the isokinetic knee peak torque in both the extension and flexion movement in the dominant and non-dominant leg, and the relationship with jumping performance. Twelve elite male handball players from the top Spanish handball division voluntary participated in the study (age 27.68 ± 4.12 years; body mass 92.89 ± 12.34 kg; body height 1.90 ± 0.05 m). The knee extensor and flexor muscle peak torque of each leg were concentrically measured at 60º/s and 180º/s with an isokinetic dynamometer. The Squat Jump and Countermovement Jump were performed on a force platform to determine power and vertical jump height. Non-significant differences were observed between legs in the isokinetic knee extension (dominant= 2.91 ± 0.53 Nm/kg vs non-dominant = 2.70 ± 0.47 Nm/kg at 60º/s; dominant = 1.90 ± 0.31 Nm/kg vs non-dominant = 1.83 ± 0.29 Nm/kg at 180º/s) and flexion peak torques (dominant = 1.76 ± 0.29 Nm/kg vs non-dominant = 1.72 ± 0.39 Nm/kg at 60º/s; dominant = 1.30 ± 0.23 Nm/kg vs non-dominant = 1.27 ± 0.35 Nm/kg at 180º/s). Low and non-significant correlation coefficients were found between the isokinetic peak torques and vertical jumping performance (SJ = 31.21 ± 4.32 cm; CMJ = 35.89 ± 4.20 cm). Similar isokinetic strength was observed between the legs; therefore, no relationship was found between the isokinetic knee flexion and extension peak torques as well as vertical jumping performance in elite handball players.
Risberg, May A; Steffen, Kathrin; Nilstad, Agnethe; Myklebust, Grethe; Kristianslund, Eirik; Moltubakk, Marie M; Krosshaug, Tron
2018-05-23
Risberg, MA, Steffen, K, Nilstad, A, Myklebust, G, Kristianslund, E, Moltubakk, MM, and Krosshaug, T. Normative quadriceps and hamstring muscle strength values for female, healthy, elite handball and football players. J Strength Cond Res XX(X): 000-000, 2018-This study presents normative values for isokinetic knee extension and flexion muscle strength tests in 350 elite, female, handball (n = 150) and football (n = 200) players. Isokinetic concentric muscle strength tests at 60°·sec were recorded bilaterally using a dynamometer. Peak torque (in Newton meter [N·m]), body mass normalized peak torque (N·m·kg), and hamstring to quadriceps ratio (H:Q ratio) for dominant and nondominant legs were recorded. The female elite players were 20.9 ± 4.0 years, started playing at the elite level at the age of 18.2 ± 2.7 years, with a mean of 9.7 ± 2.2 hours of weekly in-season training. Handball players demonstrated greater quadriceps muscle strength compared with football players (11.0%) (p < 0.001), also when normalized to body mass (4.1%) (p = 0.012), but not for weight-adjusted hamstring muscle strength. The H:Q ratio was higher on the dominant compared with the nondominant leg for handball players only (p = 0.012).The H:Q ratio was significantly lower for handball players (0.58) compared with football players (0.60) (p < 0.02). These normative values for isokinetic knee extension and flexion torques of healthy, elite, female handball and football players can be used to set rehabilitation goals for muscle strength after injury and enable comparison with uninjured legs. Significantly greater quadriceps muscle strength was found for handball players compared with football players, also when normalized to body mass.This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.
Esmaeilzadeh, S.; Akpinar, M.; Polat, S.; Yildiz, A.; Oral, A.
2015-01-01
The aim of this study was to investigate the effects of two different frequencies of whole-body vibration (WBV) training on knee extensors muscle strength in healthy young volunteers. Twenty-two eligible healthy untrained young women aged 22-31 years were allocated randomly to the 30-Hz (n=11) and 50-Hz (n=11) groups. They participated in a supervised WBV training program that consisted of 24 sessions on a synchronous vertical vibration platform (peak-to-peak displacement: 2-4 mm; type of exercises: semi-squat, one-legged squat, and lunge positions on right leg; set numbers: 2-24) three times per week for 8 weeks. Isometric and dynamic strength of the knee extensors were measured prior to and at the end of the 8-week training. In the 30-Hz group, there was a significant increase in the maximal voluntary isometric contraction (p=0.039) and the concentric peak torque (p=0.018) of knee extensors and these changes were significant (p<0.05) compared with the 50-Hz group. In addition, the eccentric peak torque of knee extensors was increased significantly in both groups (p<0.05); however, there was no significant difference between the two groups (p=0.873). We concluded that 8 weeks WBV training in 30 Hz was more effective than 50 Hz to increase the isometric contraction and dynamic strength of knee extensors as measured using peak concentric torque and equally effective with 50 Hz in improving eccentric torque of knee extensors in healthy young untrained women. PMID:26636279
The Accuracy of New and Aged Mechanical Torque Devices Employed in Five Dental Implant Systems
Karatasli, Burcin; Dinçer Kose, Onur; Kose, Taha Emre; Çene, Erhan; Aydın Aya, Serhan
2017-01-01
Purpose Friction-style and spring-style torque wrenches are used to tighten implant abutments and prosthetic screws. The mechanical stability of these torque wrenches is crucial for the implant–abutment connection. The purposes of this study were to assess the performance of five brands (Straumann, Zimmer, Implant KA, Bredent, and Biohorizons) of wrench and to evaluate possible changes in applied torque values of aged wrenches. Materials and Methods Five new and aged wrenches that had been used approximately 250 times in a 1-year period were tested. The torque applied by friction- and spring-style wrenches was measured with a specially designed strain gauge indicator. Descriptive statistics, the one-sample t-test, and the independent-samples t-test were used to analyze values obtained from all torque wrenches. Results The accuracy of new and aged torque devices of all brands except Bredent differed significantly from the target values, but the mean values for aged and new wrenches did not differ significantly from each other (p > 0.05). Values for the spring- and friction-type torque wrenches deviated from the target values by 11.6% and 10.2%, respectively. Conclusion The accuracy of aged torque wrenches is adequate for prosthetic screw tightening, but that of new torque wrenches is unsatisfactory and must be examined carefully before delivery. PMID:29238725
Legault, Zachary; Bagnall, Nicholas; Kimmerly, Derek S
2015-10-01
The study aimed to examine the effects that L-glutamine supplementation has on quadriceps muscle strength and soreness ratings following eccentric exercise. It was hypothesized that glutamine ingestion would quicken the recovery rate of peak force production and decrease muscle soreness ratings over a 72-hr recovery period. Sixteen healthy participants (8♀/8♂; 22 ± 4 years) volunteered in a double-blind, randomized, placebo-controlled crossover study. Supplement conditions consisted of isoenergetic placebo (maltodextrin, 0.6 g·kg-1·day-1) and L-glutamine (0.3 g·kg-1·day-1 + 0.3 g·kg-1·day-1 maltodextrin) ingestion once per day over 72 hr. Knee extensor peak torque at 0°, 30°, and 180° per second and muscle soreness were measured before, immediately following, 24, 48, and 72 hr posteccentric exercise. Eccentric exercise consisted of 8 sets (10 repetitions/set) of unilateral knee extension at 125% maximum concentric force with 2-min rest intervals. L-glutamine resulted in greater relative peak torque at 180°/sec both immediately after (71 ± 8% vs. 66 ± 9%), and 72 hr (91 ± 8% vs. 86 ± 7%) postexercise (all, p < .01). In men, L-glutamine produced greater (p < .01) peak torques at 30°/ sec postexercise. Men also produced greater normalized peak torques at 30°/sec (Nm/kg) in the L-glutamine condition than women (all, p < .05). In the entire sample, L-glutamine resulted in lower soreness ratings at 24 (2.8 ± 1.2 vs. 3.4 ± 1.2), 48 (2.6 ± 1.4 vs. 3.9 ± 1.2), and 72 (1.7 ± 1.2 vs. 2.9 ± 1.3) hr postexercise (p < .01). The L-glutamine supplementation resulted in faster recovery of peak torque and diminished muscle soreness following eccentric exercise. The effect of L-glutamine on muscle force recovery may be greater in men than women.
Formenti, Damiano; Ludwig, Nicola; Gargano, Marco; Bosio, Andrea; Rampinini, Ermanno; Alberti, Giampietro
2018-01-01
Although moderate relationships (|r| ∼ 0.5) were reported between skin temperature and performance-related variables (e.g., kinetic), it remains unclear whether skin temperature asymmetry reflects muscle force imbalance in cycling. Therefore, the aim of this study was to assess whether a relationship exists between kinetic and thermal asymmetry during a fatiguing exercise. Ten elite cyclists were enrolled and tested on a maximal incremental cycling test. Peak crank torques of both legs were obtained at the initial and final workload. Likewise, bilateral skin temperatures were recorded before and after exercise. Asymmetric indexes were also calculated for kinetic (AIK) and skin temperature (AIT) outcomes. The bilateral peak crank torques showed a larger difference at the final compared to the initial workload (p < 0.05) of the incremental exercise. Conversely, the bilateral skin temperature did not show any differences at both initial and final workload (p > 0.05). Additionally, trivial relationships were reported between AIK and AIT (−0.3 < r < 0.2) at the initial and final workload. The obtained results showed that changes in bilateral kinetic values did not reflect concurrent changes in bilateral skin temperatures. This finding emphasizes the difficulty of associating the asymmetry of skin temperature with those of muscle effort in elite cyclists. Lastly, our study also provided further insights on thermal skin responses during exhaustive cycling exercise in very highly-trained athletes. PMID:29507831
White, Alexander A; Kubacki, Meghan R; Samona, Jason; Telehowski, Paul; Atkinson, Patrick J
2016-06-01
Studies have shown that titanium implants can be challenging to explant due to the material's excellent biocompatibility and resulting osseointegration. Clinically, titanium alloy nail interlocking screws may require removal to dynamize a construct or revise the nail due to nonunion, infection, pain, or periprosthetic fracture. This study was designed to determine what variables influence the removal torque for titanium alloy interlocking screws. An intramedullary nail with four interlocking screws was used to stabilize a 1-cm segmental femoral defect in a canine model for 16 weeks. The animals were observed to be active following a several-day recovery after surgery. In six animals, the femora and implanted nail/screws were first tested to failure in torsion to simulate periprosthetic fracture of an implant after which the screws were then removed. In four additional animals, the screws were removed without mechanical testing. Both intraoperative insertional and extraction torques were recorded for all screws. Mechanical testing to failure broke 10/24 screws. On average, the intact screws required 70% of the insertional torque during removal while broken screws only required 16% of the insertional torque (p < 0.001). In addition, intact screws closer to the fracture required 2.8 times more removal torque than the outboard distal screw (p < 0.005). On average, the angle of rotation to peak torque was ∼80°. The peak axial load did not significantly correlate with the torque required to remove the screws. On average, the removal torque was lower than at the time of insertion, and less torque was required to remove broken screws and screws remote to the fracture. However, broken screws will require additional time to retrieve the remaining screw fragment. This study suggests that broken screws and screws in prematurely active patients will require less torque to remove. © IMechE 2016.
Morel, Baptiste; Rouffet, David M.; Saboul, Damien; Rota, Samuel; Clémençon, Michel; Hautier, Christophe A.
2015-01-01
Rapid force production is critical to improve performance and prevent injuries. However, changes in rate of force/torque development caused by the repetition of maximal contractions have received little attention. The aim of this study was to determine the relative influence of rate of torque development (RTD) and peak torque (Tpeak) on the overall performance (i.e. mean torque, Tmean) decrease during repeated maximal contractions and to investigate the contribution of contractile and neural mechanisms to the alteration of the various mechanical variables. Eleven well-trained men performed 20 sets of 6-s isokinetic maximal knee extensions at 240°·s-1, beginning every 30 seconds. RTD, Tpeak and Tmean as well as the Rate of EMG Rise (RER), peak EMG (EMGpeak) and mean EMG (EMGmean) of the vastus lateralis were monitored for each contraction. A wavelet transform was also performed on raw EMG signal for instant mean frequency (ifmean) calculation. A neuromuscular testing procedure was carried out before and immediately after the fatiguing protocol including evoked RTD (eRTD) and maximal evoked torque (eTpeak) induced by high frequency doublet (100 Hz). Tmean decrease was correlated to RTD and Tpeak decrease (R²=0.62; p<0.001; respectively β=0.62 and β=0.19). RER, eRTD and initial ifmean (0-225 ms) decreased after 20 sets (respectively -21.1±14.1, -25±13%, and ~20%). RTD decrease was correlated to RER decrease (R²=0.36; p<0.05). The eTpeak decreased significantly after 20 sets (24±5%; p<0.05) contrary to EMGpeak (-3.2±19.5 %; p=0.71). Our results show that reductions of RTD explained part of the alterations of the overall performance during repeated moderate velocity maximal exercise. The reductions of RTD were associated to an impairment of the ability of the central nervous system to maximally activate the muscle in the first milliseconds of the contraction. PMID:25901576
A fundamental model of quasi-static wheelchair biomechanics.
Leary, M; Gruijters, J; Mazur, M; Subic, A; Burton, M; Fuss, F K
2012-11-01
The performance of a wheelchair system is a function of user anatomy, including arm segment lengths and muscle parameters, and wheelchair geometry, in particular, seat position relative to the wheel hub. To quantify performance, researchers have proposed a number of predictive models. In particular, the model proposed by Richter is extremely useful for providing initial analysis as it is simple to apply and provides insight into the peak and transient joint torques required to achieve a given angular velocity. The work presented in this paper identifies and corrects a critical error; specifically that the Richter model incorrectly predicts that shoulder torque is due to an anteflexing muscle moment. This identified error was confirmed analytically, graphically and numerically. The authors have developed a corrected, fundamental model which identifies that the shoulder anteflexes only in the first half of the push phase and retroflexes in the second half. The fundamental model has been extended by the authors to obtain novel data on joint and net power as a function of push progress. These outcomes indicate that shoulder power is positive in the first half of the push phase (concentrically contracting anteflexors) and negative in the second half (eccentrically contracting retroflexors). As the eccentric contraction introduces adverse negative power, these considerations are essential when optimising wheelchair design in terms of the user's musculoskeletal system. The proposed fundamental model was applied to assess the effect of vertical seat position on joint torques and power. Increasing the seat height increases the peak positive (concentric) shoulder and elbow torques while reducing the associated (eccentric) peak negative torque. Furthermore, the transition from positive to negative shoulder torque (as well as from positive to negative power) occurs later in the push phase with increasing seat height. These outcomes will aid in the optimisation of manual wheelchair propulsion biomechanics by minimising adverse negative muscle power, and allow joint torques to be manipulated as required to minimise injury or aid in rehabilitation. Copyright © 2012. Published by Elsevier Ltd.
Góes, Suelen M; Stefanello, Joice M F; Homann, Diogo; Lodovico, Angélica; Hubley-Kozey, Cheryl L; Rodacki, André L F
2016-11-01
Góes, SM, Stefanello, JMF, Homann, D, Lodovico, A, Hubley-Kozey, CL, and Rodacki, ALF. Torque and muscle activation impairment along with insulin resistance are associated with falls in women with fibromyalgia. J Strength Cond Res 30(11): 3155-3164, 2016-Fibromyalgia (FM) is a chronic pain condition associated with reduced muscle strength, which can lead to functional incapacity and higher risk of falls. The purpose of the study was to compare maximal ankle joint torque, muscle activation, and metabolic changes between women with and without FM. In addition, the relationship between those aspects and retrospectively reported falls in women with FM was determined. Twenty-nine middle-aged women with FM and 30 controls were recruited. Fall history, pain intensity, and pain threshold were assessed. Plasma glucose levels and insulin resistance (IR) were determined. Peak torque and rate of torque development (RTD) were calculated, and muscle activation was assessed from maximum isometric voluntary ankle dorsiflexion and plantar flexion contractions. In addition, voluntary muscle activation failure of the anterior tibialis muscle during maximal dorsiflexion was calculated. When compared to controls, women with FM reported higher number of retrospectively reported falls, exhibited higher IR, showed reduced plantar flexion and dorsiflexion RTD, had lower plantar flexion peak torque, and demonstrated more antagonist coactivation and higher muscle activation failure (p ≤ 0.05). Higher muscle activation failure was explained by glucose level and pain intensity (adj R = 0.28; p ≤ 0.05). Reduced plantar flexion and dorsiflexion peak torque explained 80% of retrospectively reported falls variance; also, high antagonist coactivation (odds ratio [OR] = 1.6; p ≤ 0.05) and high IR (OR = 1.8; p ≤ 0.05) increased the chance of falls in the FM group. A combination of metabolic factors and muscle function increased the odds of retrospectively reporting a fall in FM. Both aspects may be considered in interventions designed for reducing falls in this population.
Neural and Muscular Contributions to the Age-Related Reductions in Rapid Strength.
Gerstner, Gena R; Thompson, Brennan J; Rosenberg, Joseph G; Sobolewski, Eric J; Scharville, Michael J; Ryan, Eric D
2017-07-01
The purposes of this study were to investigate the age-related differences in absolute and normalized plantarflexion rate of torque development (RTD) at early (0-50 ms) and late (100-200 ms) time intervals and to examine specific neural and muscular mechanisms contributing to these differences. Thirty-two young (20.0 ± 2.1 yr) and 20 older (69.5 ± 3.3 yr) recreationally active men performed rapid plantarflexion isometric muscle actions to examine absolute and normalized RTD and muscle activation using EMG at early and late time intervals. Ultrasonography was used to examine medial gastrocnemius muscle size, echo intensity (EI), and muscle architecture (fascicle length [FL] and pennation angle [PA]). The older men were weaker (23.9%, P < 0.001) and had lower later absolute and normalized RTD (P = 0.001-0.034) variables when compared with the young men. The older men also had higher EI (P < 0.001), smaller PA (P = 0.004), and lower later EMG amplitude values (P = 0.009-0.046). However, there were no differences in early RTD and EMG amplitude values, muscle size, or FL between groups (P = 0.097-0.914). Lower late RTD values were related to higher EI, smaller PA, and lower EMG amplitude values (r = -0.28-0.59, P = 0.001-0.044); however, late RTD values were no longer related to PA after normalizing to peak torque. Age-related alterations in muscle quality (EI), architecture, and muscle activation may influence rapid torque production at late time intervals (≥100 ms) from contraction onset. These findings highlight specific neuromuscular factors that influence the age-related reductions in RTD, which has been shown to significantly influence function and performance in older adults.
Lynch, Heidi M.; Wharton, Christopher M.; Johnston, Carol S.
2016-01-01
In spite of well-documented health benefits of vegetarian diets, less is known regarding the effects of these diets on athletic performance. In this cross-sectional study, we compared elite vegetarian and omnivore adult endurance athletes for maximal oxygen uptake (VO2 max) and strength. Twenty-seven vegetarian (VEG) and 43 omnivore (OMN) athletes were evaluated using VO2 max testing on the treadmill, and strength assessment using a dynamometer to determine peak torque for leg extensions. Dietary data were assessed using detailed seven-day food logs. Although total protein intake was lower among vegetarians in comparison to omnivores, protein intake as a function of body mass did not differ by group (1.2 ± 0.3 and 1.4 ± 0.5 g/kg body mass for VEG and OMN respectively, p = 0.220). VO2 max differed for females by diet group (53.0 ± 6.9 and 47.1 ± 8.6 mL/kg/min for VEG and OMN respectively, p < 0.05) but not for males (62.6 ± 15.4 and 55.7 ± 8.4 mL/kg/min respectively). Peak torque did not differ significantly between diet groups. Results from this study indicate that vegetarian endurance athletes’ cardiorespiratory fitness was greater than that for their omnivorous counterparts, but that peak torque did not differ between diet groups. These data suggest that vegetarian diets do not compromise performance outcomes and may facilitate aerobic capacity in athletes. PMID:27854281
Lynch, Heidi M; Wharton, Christopher M; Johnston, Carol S
2016-11-15
In spite of well-documented health benefits of vegetarian diets, less is known regarding the effects of these diets on athletic performance. In this cross-sectional study, we compared elite vegetarian and omnivore adult endurance athletes for maximal oxygen uptake (VO2 max) and strength. Twenty-seven vegetarian (VEG) and 43 omnivore (OMN) athletes were evaluated using VO2 max testing on the treadmill, and strength assessment using a dynamometer to determine peak torque for leg extensions. Dietary data were assessed using detailed seven-day food logs. Although total protein intake was lower among vegetarians in comparison to omnivores, protein intake as a function of body mass did not differ by group (1.2 ± 0.3 and 1.4 ± 0.5 g/kg body mass for VEG and OMN respectively, p = 0.220). VO2 max differed for females by diet group (53.0 ± 6.9 and 47.1 ± 8.6 mL/kg/min for VEG and OMN respectively, p < 0.05) but not for males (62.6 ± 15.4 and 55.7 ± 8.4 mL/kg/min respectively). Peak torque did not differ significantly between diet groups. Results from this study indicate that vegetarian endurance athletes' cardiorespiratory fitness was greater than that for their omnivorous counterparts, but that peak torque did not differ between diet groups. These data suggest that vegetarian diets do not compromise performance outcomes and may facilitate aerobic capacity in athletes.
One session of partial-body cryotherapy (-110 °C) improves muscle damage recovery.
Ferreira-Junior, J B; Bottaro, M; Vieira, A; Siqueira, A F; Vieira, C A; Durigan, J L Q; Cadore, E L; Coelho, L G M; Simões, H G; Bemben, M G
2015-10-01
To evaluate the effects of a single session of partial-body cryotherapy (PBC) on muscle recovery, 26 young men performed a muscle-damaging protocol that consisted of five sets of 20 drop jumps with 2-min rest intervals between sets. After the exercise, the PBC group (n = 13) was exposed to 3 min of PBC at -110 °C, and the control group (n = 13) was exposed to 3 min at 21 °C. Anterior thigh muscle thickness, isometric peak torque, and muscle soreness of knee extensors were measured pre, post, 24, 48, 72, and 96 h following exercise. Peak torque did not return to baseline in control group (P < 0.05), whereas the PBC group recovered peak torques 96 h post exercise (P > 0.05). Peak torque was also higher after PBC at 72 and 96 h compared with control group (P < 0.05). Muscle thickness increased after 24 h in the control group (P < 0.05) and was significantly higher compared with the PBC group at 24 and 96 h (P < 0.05). Muscle soreness returned to baseline for the PBC group at 72 h compared with 96 h for controls. These results indicate that PBC after strenuous exercise may enhance recovery from muscle damage. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Chagas, Mauro H.; Magalhães, Fabrício A.; Peixoto, Gustavo H. C.; Pereira, Beatriz M.; Andrade, André G. P.; Menzel, Hans-Joachim K.
2016-01-01
ABSTRACT Background Stretching exercises are able to promote adaptations in the muscle-tendon unit (MTU), which can be tested through physiological and biomechanical variables. Identifying the key variables in MTU adaptations is crucial to improvements in training. Objective To perform an exploratory factor analysis (EFA) involving the variables often used to evaluate the response of the MTU to stretching exercises. Method Maximum joint range of motion (ROMMAX), ROM at first sensation of stretching (FSTROM), peak torque (torqueMAX), passive stiffness, normalized stiffness, passive energy, and normalized energy were investigated in 36 participants during passive knee extension on an isokinetic dynamometer. Stiffness and energy values were normalized by the muscle cross-sectional area and their passive mode assured by monitoring the EMG activity. Results EFA revealed two major factors that explained 89.68% of the total variance: 53.13% was explained by the variables torqueMAX, passive stiffness, normalized stiffness, passive energy, and normalized energy, whereas the remaining 36.55% was explained by the variables ROMMAX and FSTROM. Conclusion This result supports the literature wherein two main hypotheses (mechanical and sensory theories) have been suggested to describe the adaptations of the MTU to stretching exercises. Contrary to some studies, in the present investigation torqueMAX was significantly correlated with the variables of the mechanical theory rather than those of the sensory theory. Therefore, a new approach was proposed to explain the behavior of the torqueMAX during stretching exercises. PMID:27437715
DOE Office of Scientific and Technical Information (OSTI.GOV)
Endo, Yasushi, E-mail: endo@ecei.tohoku.ac.jp; Fan, Peng; Yamaguchi, Masahiro
To understand the spin-torque effect on the noise in tunneling magnetoresistive (TMR) read heads, the GHz range noise spectra of TMR read heads with a narrow track width (w = 36 nm), and various stripe heights (h) are investigated as a function of the external magnetic field (H{sub ex}) and dc bias current density (j). The strong noise peak intensity depends on both H{sub ex} and j, indicating that the spin-torque affects the thermal mag-noise under a positive (negative) j for a positive (negative) H{sub ex}, regardless of h in the TMR heads. Due to the increased shape anisotropy, the critical current densitymore » (j{sub c}), where the non-thermal fluctuation noise originates from the spin-torque, increases markedly as the head dimension is reduced, and the maximum value of j{sub c} is approximately +1.5 × 10{sup 12} A/m{sup 2} for a head with w = 36 nm and h = 15 nm. These results demonstrate that the non-thermal fluctuation noise originating from the spin-torque in the TMR head can be suppressed in the current density range below 10{sup 12} A/m{sup 2}, as the head dimension is reduced and the shape anisotropy is increased.« less
Performance Evaluation of a Lower Limb Exoskeleton for Stair Ascent and Descent with Paraplegia*
Farris, Ryan J.; Quintero, Hugo A.; Goldfarb, Michael
2013-01-01
This paper describes the application of a powered lower limb exoskeleton to aid paraplegic individuals in stair ascent and descent. A brief description of the exoskeleton hardware is provided along with an explanation of the control methodology implemented to allow stair ascent and descent. Tests were performed with a paraplegic individual (T10 complete injury level) and data is presented from multiple trials, including the hip and knee joint torque and power required to perform this functionality. Joint torque and power requirements are summarized, including peak hip and knee joint torque requirements of 0.75 Nm/kg and 0.87 Nm/kg, respectively, and peak hip and knee joint power requirements of approximately 0.65 W/kg and 0.85 W/kg, respectively. PMID:23366287
Isokinetic profile of elbow flexion and extension strength in elite junior tennis players.
Ellenbecker, Todd S; Roetert, E Paul
2003-02-01
Descriptive study. To determine whether bilateral differences exist in concentric elbow flexion and extension strength in elite junior tennis players. The repetitive nature of tennis frequently produces upper extremity overuse injuries. Prior research has identified tennis-specific strength adaptation in the dominant shoulder and distal upper extremity musculature of elite players. No previous study has addressed elbow flexion and extension strength. Thirty-eight elite junior tennis players were bilaterally tested for concentric elbow flexion and extension muscle performance on a Cybex 6000 isokinetic dynamometer at 90 degrees/s, 210 degrees/s, and 300 degrees/s. Repeated-measures ANOVAs were used to test for differences between extremities, muscle groups, and speed. Significantly greater (P<0.002) dominant-arm elbow extension peak torque values were measured at 90 degrees/s, 210 degrees/s, and 300 degrees/s for males. Significantly greater (P<0.002) dominant-arm single-repetition work values were also measured at 90 degrees/s and 210 degrees/s for males. No significant difference was measured between extremities in elbow flexion muscular performance in males and for elbow flexion or extension peak torque and single-repetition work values in females. No significant difference between extremities was measured in elbow flexion/extension strength ratios in females and significant differences between extremities in this ratio were only present at 210 degrees/s in males (P<0.002). These data indicate muscular adaptations around the dominant elbow in male elite junior tennis players but not females. These data have ramifications for clinicians rehabilitating upper extremity injuries in patients from this population.
Eccentric and concentric muscle performance following 7 days of simulated weightlessness
NASA Technical Reports Server (NTRS)
Hayes, Judith C.; Roper, Mary L.; Mazzocca, Augustus D.; Mcbrine, John J.; Barrows, Linda H.; Harris, Bernard A.; Siconolfi, Steven F.
1992-01-01
Changes in skeletal muscle strength occur in response to chronic disuse or insufficient functional loading. The purpose of this study was to examine changes in muscle performance of the lower extremity and torso prior to and immediately after 7 days of simulated weightlessness (horizontal bed rest). A Biodex was used to determine concentric and eccentric peak torque and angle at peak torque for the back, abdomen, quadriceps, hamstring, soleus, and tibialis anterior. A reference angle of 0 degrees was set at full extension. Data were analyzed by ANOVA.
Comparison of design and torque measurements of various manual wrenches.
Neugebauer, Jörg; Petermöller, Simone; Scheer, Martin; Happe, Arndt; Faber, Franz-Josef; Zoeller, Joachim E
2015-01-01
Accurate torque application and determination of the applied torque during surgical and prosthetic treatment is important to reduce complications. A study was performed to determine and compare the accuracy of manual wrenches, which are available in different designs with a large range of preset torques. Thirteen different wrench systems with a variety of preset torques ranging from 10 to 75 Ncm were evaluated. Three different designs were available, with a spring-in-coil or toggle design as an active mechanism or a beam as a passive mechanism, to select the preset torque. To provide a clinically relevant analysis, a total of 1,170 torque measurements in the range of 10 to 45 Ncm were made in vitro using an electronic torque measurement device. The absolute deviations in Ncm and percent deviations across all wrenches were small, with a mean of -0.24 ± 2.15 Ncm and -0.84% ± 11.72% as a shortfall relative to the preset value. The greatest overage was 8.2 Ncm (82.5%), and the greatest shortfall was 8.47 Ncm (46%). However, extreme values were rare, with 95th-percentile values of -1.5% (lower value) and -0.16% (upper value). A comparison with respect to wrench design revealed significantly higher deviations for coil and toggle-style wrenches than for beam wrenches. Beam wrenches were associated with a lower risk of rare extreme values thanks to their passive mechanism of achieving the selected preset torque, which minimizes the risk of harming screw connections.
Specialized properties of the triceps surae muscle-tendon unit in professional ballet dancers.
Moltubakk, M M; Magulas, M M; Villars, F O; Seynnes, O R; Bojsen-Møller, J
2018-05-03
This study compared professional ballet dancers (n = 10) to nonstretching controls (n = 10) with the purpose of comparing muscle and tendon morphology, mechanical, neural, and functional properties of the triceps surae and their role for ankle joint flexibility. Torque-angle and torque-velocity data were obtained during passive and active conditions by use of isokinetic dynamometry, while tissue morphology and mechanical properties were evaluated by ultrasonography. Dancers displayed longer gastrocnemius medialis fascicles (55 ± 5 vs 47 ± 6 mm) and a longer (207 ± 33 vs 167 ± 10 mm) and more compliant (230 ± 87 vs 364 ± 106 N/mm) Achilles tendon compared to controls. Greater passive ankle dorsiflexion range of motion (40 ± 7 vs 17 ± 9°) was seen in dancers, resulting from greater fascicle strain and greater elongation of the muscle. Peak electromyographic (EMG) activity recorded during passive stretching was lower in dancers, and at common joint angles, dancers displayed lower EMG amplitude and lower passive joint stiffness. No differences between groups were seen in maximal isometric plantar flexor torque, isokinetic peak torque, angle of peak torque, or work. In conclusion, the greater ankle joint flexibility of professional dancers seems attributed to multiple differences in morphological and mechanical properties of muscle and tendinous tissues, and to factors related to neural activation. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Palmer, Ty B; Hawkey, Matt J; Smith, Doug B; Thompson, Brennan J
2014-05-01
The purpose of this study was to examine the effectiveness of maximal and rapid isometric torque characteristics of the posterior muscles of the hip and thigh and lower-body power to discriminate between professional status in full-time and part-time professional soccer referees. Seven full-time (mean ± SE: age = 36 ± 2 years; mass = 82 ± 4 kg; and height = 179 ± 3 cm) and 9 part-time (age = 34 ± 2 years; mass = 84 ± 2 kg; and height = 181 ± 2 cm) professional soccer referees performed 2 isometric maximal voluntary contractions (MVCs) of the posterior muscles of the hip and thigh. Peak torque (PT) and absolute and relative rate of torque development (RTD) were calculated from a torque-time curve that was recorded during each MVC. Lower-body power output was assessed through a vertical jump test. Results indicated that the rapid torque characteristics were greater in the full-time compared with the part-time referees for absolute RTD (p = 0.011) and relative RTD at 1/2 (p = 0.022) and 2/3 (p = 0.033) of the normalized torque-time curve. However, no differences were observed for PT (p = 0.660) or peak power (Pmax, p = 0.149) between groups. These findings suggest that rapid torque characteristics of the posterior muscles of the hip and thigh may be sensitive and effective measures for discriminating between full-time and part-time professional soccer referees. Strength and conditioning coaches may use these findings to help identify professional soccer referees with high explosive strength-related capacities and possibly overall refereeing ability.
Pelvic rotation torque during fast-pitch softball hitting under three ball height conditions.
Iino, Yoichi; Fukushima, Atsushi; Kojima, Takeji
2014-08-01
The purpose of this study was to investigate the relevance of hip joint angles to the production of the pelvic rotation torque in fast-pitch softball hitting and to examine the effect of ball height on this production. Thirteen advanced female softball players hit stationary balls at three different heights: high, middle, and low. The pelvic rotation torque, defined as the torque acting on the pelvis through the hip joints about the pelvic superior-inferior axis, was determined from the kinematic and force plate data using inverse dynamics. Irrespective of the ball heights, the rear hip extension, rear hip external rotation, front hip adduction, and front hip flexion torques contributed to the production of pelvic rotation torque. Although the contributions of the adduction and external rotation torques at each hip joint were significantly different among the ball heights, the contributions of the front and rear hip joint torques were similar among the three ball heights owing to cancelation of the two torque components. The timings of the peaks of the hip joint torque components were significantly different, suggesting that softball hitters may need to adjust the timings of the torque exertions fairly precisely to rotate the upper body effectively.
Recovery Kinetics of Knee Flexor and Extensor Strength after a Football Match
Draganidis, Dimitrios; Chatzinikolaou, Athanasios; Avloniti, Alexandra; Barbero-Álvarez, José C.; Mohr, Magni; Malliou, Paraskevi; Gourgoulis, Vassilios; Deli, Chariklia K.; Douroudos, Ioannis I.; Margonis, Konstantinos; Gioftsidou, Asimenia; Fouris, Andreas D.; Jamurtas, Athanasios Z.; Koutedakis, Yiannis; Fatouros, Ioannis G.
2015-01-01
We examined the temporal changes of isokinetic strength performance of knee flexor (KF) and extensor (KE) strength after a football match. Players were randomly assigned to a control (N = 14, participated only in measurements and practices) or an experimental group (N = 20, participated also in a football match). Participants trained daily during the two days after the match. Match and training overload was monitored with GPS devices. Venous blood was sampled and muscle damage was assessed pre-match, post-match and at 12h, 36h and 60h post-match. Isometric strength as well as eccentric and concentric peak torque of knee flexors and extensors in both limbs (dominant and non-dominant) were measured on an isokinetic dynamometer at baseline and at 12h, 36h and 60h after the match. Functional (KFecc/KEcon) and conventional (KFcon/KEcon) ratios were then calculated. Only eccentric peak torque of knee flexors declined at 60h after the match in the control group. In the experimental group: a) isometric strength of knee extensors and knee flexors declined (P<0.05) at 12h (both limbs) and 36h (dominant limb only), b) eccentric and concentric peak torque of knee extensors and flexors declined (P<0.05) in both limbs for 36h at 60°/s and for 60h at 180°/s with eccentric peak torque of knee flexors demonstrating a greater (P<0.05) reduction than concentric peak torque, c) strength deterioration was greater (P<0.05) at 180°/s and in dominant limb, d) the functional ratio was more sensitive to match-induced fatigue demonstrating a more prolonged decline. Discriminant and regression analysis revealed that strength deterioration and recovery may be related to the amount of eccentric actions performed during the match and athletes' football-specific conditioning. Our data suggest that recovery kinetics of knee flexor and extensor strength after a football match demonstrate strength, limb and velocity specificity and may depend on match physical overload and players' physical conditioning level. PMID:26043222
[Biomechanical testing of the new torque-segmented arch (TSA)].
Wichelhaus, A; Sander, F G
1995-07-01
New torque-segmented arch wires are presented which consist of a superelastic anterior component with 30 degrees or 45 degrees torque and which are connected to 2 steel lateral components by means of a crimped connector. When using such torque-segmented arch wires, the crimped connector rests mesially to the canine bracket and the lateral components exhibit a torque of 0 degree. The use of the torque-segmented arch wires requires the practitioner to adjust the anterior tooth segment, to bend in first order bends in the steel lateral portion as well as to bend in a sweep to avoid an anterior tooth extrusion, and, if desired, to bend in third order bends to influence premolars and molars. In some cases the simultaneous application of palatal arches can become necessary, because each torque transfer results in a transversal enlargement in the molar area. Compared to conventional steel wires with dimensions of 0.016 x 0.022 in which an anterior tooth torque is bent, the torque segmented arch wires exhibit considerably fewer side effects, but there is a larger distally rotating moment for the molars. 1. When applying torque-segmented arch wires, the extrusive force transferred to the anterior teeth is considerably smaller. 2. The protrusive force acting on the anterior teeth is also considerably smaller, which results in a reduced demand being placed on the anchorage of the molars. 3. The torque transfer to the incisors rests in a quite moderate range, even in the case of a 50 degrees torque. For this reason, the practitioner can expect diminished or no resorptions at all compared to the aforementioned steel wires. 4. The Martensite plateau of the torque-segmented arch wires exhibit constant moments in large areas so that such arch wires can be used in almost every anterior tooth position. 5. The segmented wires presented here can be applied not only in the case of the standard edgewise technique but also in each case of the straight-wire technique. 6. These new arch wires require no readjustment of torque values. 7. To control the transferred torque values it is recommended that the already transferred torque values be monitored during each check-up with the help of the described torque key. 8. When the torque values of the brackets are known, the torque key renders frequent patient X-rays superfluous. 9. When the desired torque values are attained, treatment can proceed using conventional arch wires.
NASA Astrophysics Data System (ADS)
English, Kirk L.; Hackney, Kyle J.; De Witt, John K.; Ploutz-Snyder, Robert J.; Goetchius, Elizabeth L.; Ploutz-Snyder, Lori L.
2013-11-01
IntroductionInternational Space Station (ISS) crewmembers perform muscle strength and endurance testing pre- and postflight to assess the physiologic adaptations associated with long-duration exposure to microgravity. However, a reliable and standardized method to document strength changes in-flight has not been established. To address this issue, a proprietary dynamometer, the Muscle Atrophy Research and Exercise System (MARES) has been developed and flown aboard the ISS. The aims of this ground-based investigation were to: (1) evaluate the test-retest reliability of MARES and (2) determine its agreement with a commercially available isokinetic dynamometer previously used for pre- and postflight medical testing. MethodsSix males (179.5±4.7 cm; 82.0±8.7 kg; 31.3±4.0 yr) and four females (163.2±7.3 cm; 63.2±1.9 kg; 32.3±6.8 yr) completed two testing sessions on a HUMAC NORM isokinetic dynamometer (NORM) and two sessions on MARES using a randomized, counterbalanced, cross-over design. Peak torque values at 60° and 180° s-1 were calculated from five maximal repetitions of knee extension (KE) and knee flexion (KF) for each session. Total work at 180° s-1 was determined from the area under the torque versus displacement curve during 20 maximal repetitions of KE and KF. ResultsIntraclass correlation coefficients were relatively high for both devices (0.90-0.99). Only one dependent measure, KE peak torque at 60° s-1 exhibited good concordance between devices (ρ=0.92) and a small average difference (0.9±17.3 N m). ConclusionMARES demonstrated acceptable test-retest reliability and thus should serve as a good tool to monitor in-flight strength changes. However, due to poor agreement with NORM, it is not advisable to compare absolute values obtained on these devices.
NASA Technical Reports Server (NTRS)
Berg, H. E.; Dudley, G. A.; Hather, B.; Tesch, P. A.
1993-01-01
The response of skeletal muscle to unweighting was studied in six healthy males who were subjected to four weeks of lowerlimb suspension. They performed three bouts of 30 consecutive maximal concentric knee extensions, before unloading and the day after (POST 1), 4 days after (POST 2) and 7 weeks after (REC) resumed weight-bearing. Peak torque of each contraction was recorded and work was calculated as the mean of the average peak torque for the three bouts and fatigability was measured as the decline in average peak torque over bouts. Needle biopsies were obtained from m. vastus lateralis of each limb before and at POST 1. Muscle fibre type composition and area, capillarity and the enzyme activities of citrate synthase (CS) and phosphofructokinase (PFK) were subsequently analysed. Mean average peak torque for the three bouts at POST1, POST2 and REC was reduced (P < 0.05) by 17, 13 and 7%, respectively. Fatigability was greater (P < 0.05) at POST2 than before unloading. Type I, IIA and IIB percentage, Type I and II area and capillaries per fibre of Type I and II did not change (P > 0.05) in response to unloading. The activity of CS, but not PFK, decreased (P < 0.05) after unloading. The weight-bearing limb showed no changes in the variables measured. The results of this study suggest that this human lowerlimb suspension model produces substantial impairments of work and oxidative capacity of skeletal muscle. The performance decrements are most likely induced by lack of weight-bearing.
Hewett, Timothy E; Myer, Gregory D; Zazulak, Bohdanna T
2008-09-01
Our purpose was to determine if females demonstrate decreased hamstrings to quadriceps peak torque (H/Q) ratios compared to males and if H/Q ratios increase with increased isokinetic velocity in both sexes. Maturation disproportionately increases hamstrings peak torque at high velocity in males, but not females. Therefore, we hypothesised that mature females would demonstrate decreased H/Q ratios compared to males and the difference in H/Q ratio between sexes would increase as isokinetic velocity increased. Studies that analysed the H/Q ratio with gravity corrected isokinetic strength testing reported between 1967 and 2004 were included in our review and analysis. Keywords were hamstrings/quadriceps, isokinetics, peak torque and gravity corrected. Medline and Smart databases were searched combined with cross-checked bibliographic reference lists of the publications to determine studies to be included. Twenty-two studies were included with a total of 1568 subjects (1145 male, 423 female). Males demonstrated a significant correlation between H/Q ratio and isokinetic velocity (R=0.634, p<0.0001), and a significant difference in the isokinetic H/Q ratio at the lowest angular velocity (47.8+/-2.2% at 30 degrees /s) compared to the highest velocity (81.4+/-1.1% at 360 degrees /s, p<0.001). In contrast, females did not demonstrate a significant relationship between H/Q ratio and isokinetic velocity (R=0.065, p=0.77) or a change in relative hamstrings strength as the speed increased (49.5+/-8.8% at 30 degrees /s; 51.0+/-5.7% at 360 degrees /s, p=0.84). Gender differences in isokinetic H/Q ratios were not observed at slower angular velocities. However, at high knee flexion/extension angular velocities, approaching those that occur during sports activities, significant gender differences were observed in the H/Q ratio. Females, unlike males, do not increase hamstrings to quadriceps torque ratios at velocities that approach those of functional activities.
Cha, Jun-Youl; Kim, Jae-Hak; Hong, Ju; Choi, Young-Tae; Kim, Min-Ho; Cho, Ji-Hyun; Ko, Il-Gyu; Jee, Yong-Seok
2014-02-01
The aim of this study was to investigate the effects of a 12-week rehabilitation program on body composition, shoulder pain, and isokinetic internal/external torques of pitchers with impingement syndrome. A total of 30 pitchers were divided into 2 groups: experimental group (EG, n = 16) and control group (CG, n= 14). The rehabilitation program consisted of physical therapy, warm-up, work-out, and cool-down. As results, body weight and fat mass of EG were decreased whereas muscle mass of EG was significantly increased after the experiment. The pain degrees in resting, normal daily activity, and strenuous activity on the numeric pain rating scale were significantly decreased in the EG. The internal and external peak torques (PTs) of uninvolved and involved sides of EG were increased in EG after 12 weeks. Such results provide a deficit ratio of both sides in EG close to normal values. The ratios of internal/external PTs in EG were also close to the reference values. The internal and external total works of both sides in EG were similar to the values of PT. The fatigue indices of internal and external rotators of both sides in EG were decreased. As a conclusion, a 12-week rehabilitation program reduced the shoulder pain, improved the body composition and enhanced the isokinetic shoulder internal/external rotators in EG with impingement symptoms. Also the study suggested that the rehabilitation program evened out the ratio between internal and external rotators and lowered the fatigue level after the experiment.
Cha, Jun-Youl; Kim, Jae-Hak; Hong, Ju; Choi, Young-Tae; Kim, Min-Ho; Cho, Ji-Hyun; Ko, Il-Gyu; Jee, Yong-Seok
2014-01-01
The aim of this study was to investigate the effects of a 12-week rehabilitation program on body composition, shoulder pain, and isokinetic internal/external torques of pitchers with impingement syndrome. A total of 30 pitchers were divided into 2 groups: experimental group (EG, n = 16) and control group (CG, n= 14). The rehabilitation program consisted of physical therapy, warm-up, work-out, and cool-down. As results, body weight and fat mass of EG were decreased whereas muscle mass of EG was significantly increased after the experiment. The pain degrees in resting, normal daily activity, and strenuous activity on the numeric pain rating scale were significantly decreased in the EG. The internal and external peak torques (PTs) of uninvolved and involved sides of EG were increased in EG after 12 weeks. Such results provide a deficit ratio of both sides in EG close to normal values. The ratios of internal/external PTs in EG were also close to the reference values. The internal and external total works of both sides in EG were similar to the values of PT. The fatigue indices of internal and external rotators of both sides in EG were decreased. As a conclusion, a 12-week rehabilitation program reduced the shoulder pain, improved the body composition and enhanced the isokinetic shoulder internal/external rotators in EG with impingement symptoms. Also the study suggested that the rehabilitation program evened out the ratio between internal and external rotators and lowered the fatigue level after the experiment. PMID:24678503
NASA Technical Reports Server (NTRS)
Colliander, E. B.; Dudley, G. A.; Tesch, P. A.
1988-01-01
Force output and fatigue and recovery patterns were studied during intermittent short-term exercise. 27 men performed three bouts of 30 maximal unilateral knee extensions on 2 different occasions. Blood flow was maintained or occluded during recovery periods (60 s). Blood flow was restricted by inflating a pneumatic cuff placed around the proximal thigh. Muscle biopsies from vastus lateralis were analyzed for identification of fast twitch (FT) and slow twitch (ST) fibers and relative FT area. Peak torque decreased during each bout of exercise and more when blood flow was restricted during recovery. Initial peak torque (IPT) and average peak torque (APT) decreased over the three exercise bouts. This response was 3 fold greater without than with blood flow during recovery. IPT and APT decreased more in individuals with mainly FT fibers than in those with mainly ST fibers. It is suggested that performance during repeated bouts of maximal concentric contractions differs between individuals with different fiber type composition. Specifically, in high intensity, intermittent exercise with emphasis on anaerobic energy release a high FT composition may not necessarily be advantageous for performance.
Isokinetic knee joint evaluation in track and field events.
Deli, Chariklia K; Paschalis, Vassilis; Theodorou, Anastasios A; Nikolaidis, Michalis G; Jamurtas, Athanasios Z; Koutedakis, Yiannis
2011-09-01
The purpose of this study was to evaluate maximal torque of the knee flexors and extensors, flexor/extensor ratios, and maximal torque differences between the 2 lower extremities in young track and field athletes. Forty male track and field athletes 13-17 years old and 20 male nonathletes of the same age participated in the study. Athletes were divided into 4 groups according to their age and event (12 runners and 10 jumpers 13-15 years old, 12 runners and 6 jumpers 16-17 years old) and nonathletes into 2 groups of the same age. Maximal torque evaluation of knee flexors and extensors was performed on an isokinetic dynamometer at 60°·s(-1). At the age of 16-17 years, jumpers exhibited higher strength values at extension than did runners and nonathletes, whereas at the age of 13-15 years, no significant differences were found between events. Younger athletes were weaker than older athletes at flexion. Runners and jumpers were stronger than nonathletes in all relative peak torque parameters. Nonathletes exhibited a higher flexor/extensor ratio compared with runners and jumpers. Strength imbalance in athletes was found between the 2 lower extremities in knee flexors and extensors and also at flexor/extensor ratio of the same extremity. Young track and field athletes exhibit strength imbalances that could reduce their athletic performance, and specific strength training for the weak extremity may be needed.
40 CFR 1054.505 - How do I test engines?
Code of Federal Regulations, 2010 CFR
2010-07-01
... following methods for confirming torque values for nonhandheld engines: (i) Calculate torque-related cycle... is valid. (ii) Evaluate each mode separately to validate the duty cycle. All torque feedback values recorded during non-idle sampling periods must be within ±2 percent of the reference value or within ±0.27...
Effect of a lateral step-up exercise protocol on quadriceps and lower extremity performance.
Worrell, T W; Borchert, B; Erner, K; Fritz, J; Leerar, P
1993-12-01
Closed kinetic chain exercises have been promoted as more functional and more appropriate than open kinetic chain exercises. Limited research exists demonstrating the effect of closed kinetic chain exercise on quadriceps and lower extremity performance. The purpose of this study was to determine the effect of a lateral step-up exercise protocol on isokinetic quadriceps peak torque and the following lower extremity activities: 1) leg press, 2) maximal step-up repetitions with body weight plus 25%, 3) hop for distance, and 4) 6-m timed hop. Twenty subjects participated in a 4-week training period, and 18 subjects served as controls. For the experimental group, a repeated measure ANOVA comparing pretest and posttest values revealed significant improvements in the leg press (p < or = .05), step-ups (p < or = .05), hop for distance (p < or = .05), and hop for time (p < or = .05) and no significant increase in isokinetic quadriceps peak torque (p > or = .05). Over the course of the training period, weight used for the step-up exercise increased (p < or = .05), repetitions decreased (p < or = .05), and step-up work did not change (p > or = .05). For the control group, no significant change (p > or = .05) occurred in any variable. The inability of the isokinetic dynamometer to detect increases in quadriceps performance is important because the isokinetic values are frequently used as criteria for return to functional activities. We conclude that closed kinetic chain testing and exercise provide additional means to assess and rehabilitate the lower extremity.
Accuracy of torque-limiting devices: A comparative evaluation.
Albayrak, Haydar; Gumus, Hasan Onder; Tursun, Funda; Kocaagaoglu, Hasan Huseyin; Kilinc, Halil Ibrahim
2017-01-01
To prevent the loosening of implant screws, clinicians should be aware of the output torque values needed to achieve the desired preload. Accurate torque-control devices are crucial in this regard; however, little information is currently available comparing the accuracy of mechanical with that of electronic torque-control devices. The purpose of this in vitro study was to identify and compare the accuracy of different types of torque-control devices. Devices from 5 different dental implant manufacturers were evaluated, including 2 spring-type (Straumann, Implance) mechanical devices (MTLD), 2 friction-type (Biohorizons, Dyna) MTLDs, and 1 (Megagen) electronic torque-control device (ETLD). For each manufacturer, 5 devices were tested 5 times with a digital torque tester, and the average for each device was calculated and recorded. The percentage of absolute deviations from the target torque values (PERDEV) were calculated and compared by using 1-way ANOVA. A 1-sample t test was used to evaluate the ability of each device to achieve its target torque value within a 95% confidence interval for the true population mean of measured values (α=.05 for all statistical analyses). One-way ANOVAs revealed statistically significant differences among torque-control devices (P<.001). ETLD showed higher PERDEVs (28.33 ±9.53) than MTLDs (P<.05), whereas PERDEVS of friction-type (7.56 ±3.64) and spring-type (10.85 ±4.11) MTLDs did not differ significantly. In addition, devices produced by Megagen had a significantly higher (P<.05) PERDEV (28.33 ±9.53) other devices, whereas no differences were found in devices manufactured by Biohorizons (7.31 ±5.34), Dyna (7.82 ±1.08), Implance (8.43 ±4.77), and Straumann (13.26 ±0.79). However, 1-sample t tests showed none of the torque-control devices evaluated in this study were capable of achieving their target torque values (P<.05). Within the limitations of this in vitro study, MTLDs were shown to be significantly more accurate than ETLDs. However, none of the torque-control devices evaluated were able to meet their target torque values successfully. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Spin current and spin transfer torque in ferromagnet/superconductor spin valves
NASA Astrophysics Data System (ADS)
Moen, Evan; Valls, Oriol T.
2018-05-01
Using fully self-consistent methods, we study spin transport in fabricable spin valve systems consisting of two magnetic layers, a superconducting layer, and a spacer normal layer between the ferromagnets. Our methods ensure that the proper relations between spin current gradients and spin transfer torques are satisfied. We present results as a function of geometrical parameters, interfacial barrier values, misalignment angle between the ferromagnets, and bias voltage. Our main results are for the spin current and spin accumulation as functions of position within the spin valve structure. We see precession of the spin current about the exchange fields within the ferromagnets, and penetration of the spin current into the superconductor for biases greater than the critical bias, defined in the text. The spin accumulation exhibits oscillating behavior in the normal metal, with a strong dependence on the physical parameters both as to the structure and formation of the peaks. We also study the bias dependence of the spatially averaged spin transfer torque and spin accumulation. We examine the critical-bias effect of these quantities, and their dependence on the physical parameters. Our results are predictive of the outcome of future experiments, as they take into account imperfect interfaces and a realistic geometry.
Biomechanical design of escalading lower limb exoskeleton with novel linkage joints.
Zhang, Guoan; Liu, Gangfeng; Ma, Sun; Wang, Tianshuo; Zhao, Jie; Zhu, Yanhe
2017-07-20
In this paper, an obstacle-surmounting-enabled lower limb exoskeleton with novel linkage joints that perfectly mimicked human motions was proposed. Currently, most lower exoskeletons that use linear actuators have a direct connection between the wearer and the controlled part. Compared to the existing joints, the novel linkage joint not only fitted better into compact chasis, but also provided greater torque when the joint was at a large bend angle. As a result, it extended the angle range of joint peak torque output. With any given power, torque was prioritized over rotational speed, because instead of rotational speed, sufficiency of torque is the premise for most joint actions. With insufficient torque, the exoskeleton will be a burden instead of enhancement to its wearer. With optimized distribution of torque among the joints, the novel linkage method may contribute to easier exoskeleton movements.
The influence of arch supports on knee torques relevant to knee osteoarthritis.
Franz, Jason R; Dicharry, Jay; Riley, Patrick O; Jackson, Keith; Wilder, Robert P; Kerrigan, D Casey
2008-05-01
Changes in footwear and foot orthotic devices have been shown to significantly alter knee joint torques thought to be relevant to the progression if not the development of knee osteoarthritis (OA) in the medial tibiofemoral compartment. The purpose of this study was to determine if commonly prescribed arch support cushions promote a medial force bias during gait similar to medial-wedged orthotics, thereby increasing knee varus torque during both walking and running. Twenty-two healthy, physically active young adults (age, 29.2 +/- 5.1 yr) were analyzed at their self-selected walking and running speeds in control shoes with and without arch support cushions. Three-dimensional motion capture data were collected in synchrony with ground reaction force (GRF) data collected from an instrumented treadmill. Peak external knee varus torque during walking and running were calculated through a full inverse dynamic model and compared. Peak knee varus torque was statistically significantly increased by 6% (0.01 +/- 0.02 N.m.(kg.m)(-1)) in late stance during walking and by 4% (0.03 +/- 0.03 N.m.(kg.m)(-1)) during running with the addition of arch support cushions. The addition of material under the medial aspect of the foot by way of a flexible arch support promotes a medial force bias during walking and running, significantly increasing knee varus torque. These findings suggest that discretion be employed with regard to the prescription of commonly available orthotic insoles like arch support cushions.
Butterfield, Timothy A; Herzog, Walter
2006-05-01
Muscle strain injuries are some of the most frequent injuries in sports and command a great deal of attention in an effort to understand their etiology. These injuries may be the culmination of a series of subcellular events accumulated through repetitive lengthening (eccentric) contractions during exercise, and they may be influenced by a variety of variables including fiber strain magnitude, peak joint torque, and starting muscle length. To assess the influence of these variables on muscle injury magnitude in vivo, we measured fiber dynamics and joint torque production during repeated stretch-shortening cycles in the rabbit tibialis anterior muscle, at short and long muscle lengths, while varying the timing of activation before muscle stretch. We found that a muscle subjected to repeated stretch-shortening cycles of constant muscle-tendon unit excursion exhibits significantly different joint torque and fiber strains when the timing of activation or starting muscle length is changed. In particular, measures of fiber strain and muscle injury were significantly increased by altering activation timing and increasing the starting length of the muscle. However, we observed differential effects on peak joint torque during the cyclic stretch-shortening exercise, as increasing the starting length of the muscle did not increase torque production. We conclude that altering activation timing and muscle length before stretch may influence muscle injury by significantly increasing fiber strain magnitude and that fiber dynamics is a more important variable than muscle-tendon unit dynamics and torque production in influencing the magnitude of muscle injury.
Santamaría-Arrieta, Gorka; Brizuela-Velasco, Aritza; Fernández-González, Felipe J.; Chávarri-Prado, David; Chento-Valiente, Yelko; Solaberrieta, Eneko; Diéguez-Pereira, Markel; Yurrebaso-Asúa, Jaime
2016-01-01
Background This study evaluated the influence of implant site preparation depth on primary stability measured by insertion torque and resonance frequency analysis (RFA). Material and Methods Thirty-two implant sites were prepared in eight veal rib blocks. Sixteen sites were prepared using the conventional drilling sequence recommended by the manufacturer to a working depth of 10mm. The remaining 16 sites were prepared using an oversize drilling technique (overpreparation) to a working depth of 12mm. Bone density was determined using cone beam computerized tomography (CBCT). The implants were placed and primary stability was measured by two methods: insertion torque (Ncm), and RFA (implant stability quotient [ISQ]). Results The highest torque values were achieved by the conventional drilling technique (10mm). The ANOVA test confirmed that there was a significant correlation between torque and drilling depth (p<0.05). However, no statistically significant differences were obtained between ISQ values at 10 or 12 mm drilling depths (p>0.05) at either measurement direction (cortical and medullar). No statistical relation between torque and ISQ values was identified, or between bone density and primary stability (p >0.05). Conclusions Vertical overpreparation of the implant bed will obtain lower insertion torque values, but does not produce statistically significant differences in ISQ values. Key words:Implant stability quotient, overdrilling, primary stability, resonance frequency analysis, torque. PMID:27398182
Buckner, Samuel L; Jenkins, Nathaniel D M; Costa, Pablo B; Ryan, Eric D; Herda, Trent J; Cramer, Joel T
2015-05-01
The purpose of the present study was to compare the passive angle-torque curves and the passive stiffness (PS, N m °(-)(1)) values recorded simultaneously from a load cell versus an isokinetic dynamometer during dorsiflexion stretch tolerance assessments in vivo. Nine healthy men (mean ± SD age = 21.4 ± 1.6 years) completed stretch tolerance assessments on a custom-built apparatus where passive torque was measured simultaneously from an isokinetic dynamometer and a load cell. Passive torque values that corresponded with the last 10° of dorsiflexion, verified by surface electromyographic amplitude, were analyzed for each device (θ1, θ2, θ3, …, θ10). Passive torque values measured with the load cell were greater (p ≤ 0.05) than the dynamometer torque values for θ4 through θ10. There were more statistical differentiations among joint angles for passive torque measured by the load cell, and the load cell measured a greater (p ≤ 0.01) increase in passive torque and PS than the isokinetic dynamometer. These findings suggested that when examining the angle-torque curves from passive dorsiflexion stretch tolerance tests, a load cell placed under the distal end of the foot may be more sensitive than the torque recorded from an isokinetic dynamometer. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
Arias, Ana; de Vasconcelos, Rafaela Andrade; Hernández, Alexis; Peters, Ove A
2017-03-01
The purpose of this study was to assess the ex vivo torsional performance of a novel rotary system in small root canals after 2 different glide path preparations. Each independent canal of 8 mesial roots of mandibular molars was randomly assigned to achieve a reproducible glide path with a new set of either PathFile #1 (Dentsply Maillefer, Ballaigues, Switzerland) and #2 or ProGlider (Dentsply Maillefer) after negotiation with a 10 K-file. After glide path preparation, root canals in both groups were shaped with the same sequence of ProTaper Gold (Dentsply Tulsa Dental Specialties, Tulsa, OK) following the directions for use recommended by the manufacturer. A total of 16 new sets of each instrument of the ProTaper Gold (PTG) system were used. The tests were run in a standardized fashion in a torque-testing platform. Peak torque (Ncm) and force (N) were registered during the shaping procedure and compared with Student t tests after normal distribution of data was confirmed. No significant differences were found for any of the instruments in peak torque or force after the 2 different glide path preparations (P > .05). Data presented in this study also serve as a basis for the recommended torque for the use of PTG instruments. Under the conditions of this study, differences in the torsional performance of PTG rotary instruments after 2 different glide path preparations could not be shown. The different geometry of glide path rotary systems seemed to have no effect on peak torque and force induced by PTG rotary instruments when shaping small root canals in extracted teeth. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Installation Torque Tables for Noncritical Applications
NASA Technical Reports Server (NTRS)
Rivera-Rosario, Hazel T.; Powell, Joseph S.
2017-01-01
The objective of this project is to define torque values for bolts and screws when loading is not a concern. Fasteners require a certain torque to fulfill its function and prevent failure. NASA Glenn Research Center did not have a set of fastener torque tables for non-critical applications without loads, usually referring to hand-tight or wrench-tight torqueing. The project is based on two formulas, torque and pullout load. Torque values are calculated giving way to preliminary data tables. Testing is done to various bolts and metal plates, torqueing them until the point of failure. Around 640 torque tables were developed for UNC, UNF, and M fasteners. Different lengths of thread engagement were analyzed for the 5 most common materials used at GRC. The tables were put together in an Excel spreadsheet and then formatted into a Word document. The plan is to later convert this to an official technical publication or memorandum.
The isokinetic strength profile of elite soccer players according to playing position
Grygorowicz, Monika; Hojszyk, Radosław; Jadczak, Łukasz
2017-01-01
The aim of this study was to compare isokinetic strength performance profiles in elite soccer players across different field positions. A total of 111 elite international players of Polish Ekstraklasa (the top division in Poland) were examined during the 2010–2015 seasons. The players were classified into six positional roles: central defenders (CD), external defenders (ED), central midfielders (CM), external midfielders (EM), forwards (F), and goalkeepers (G). The concentric isokinetic strength (peak torque [PT] of quadriceps and hamstrings, H/Q ratios) was calculated for the dominant leg and the non-dominant leg at angular velocity of 1.05 rad ·s–1, whereas to assess isokinetic muscle endurance, the total work [TW] at angular velocity of 4.19 rad ·s–1, was taken into consideration. The results showed that isokinetic strength performance varies significantly among players in different playing positions. The analysis of PT for quadriceps (PT-Q) and hamstrings (PT-H) generally showed that the goalkeepers and central midfielders had lower strength levels compared to other playing positions. In the case of PT-H and hamstring/quadricep (H/Q) peak torque ratios, statistically significant differences were also noted for the legs, where mean values noted for the dominant leg were higher than for the non-dominant leg. For TW for quadriceps (TW-Q) and hamstrings (TW-H), statistically significant differences were noted only between playing positions. TW-Q values for goalkeepers were lower than for central defenders and external midfielders. TW-H values for goalkeepers were lower than for central midfielders, central defenders and external midfielders. This study showed that specific functional activity of players in individual positions on the field influences the varied profile of isokinetic strength performance. PMID:28759603
The isokinetic strength profile of elite soccer players according to playing position.
Śliwowski, Robert; Grygorowicz, Monika; Hojszyk, Radosław; Jadczak, Łukasz
2017-01-01
The aim of this study was to compare isokinetic strength performance profiles in elite soccer players across different field positions. A total of 111 elite international players of Polish Ekstraklasa (the top division in Poland) were examined during the 2010-2015 seasons. The players were classified into six positional roles: central defenders (CD), external defenders (ED), central midfielders (CM), external midfielders (EM), forwards (F), and goalkeepers (G). The concentric isokinetic strength (peak torque [PT] of quadriceps and hamstrings, H/Q ratios) was calculated for the dominant leg and the non-dominant leg at angular velocity of 1.05 rad ·s-1, whereas to assess isokinetic muscle endurance, the total work [TW] at angular velocity of 4.19 rad ·s-1, was taken into consideration. The results showed that isokinetic strength performance varies significantly among players in different playing positions. The analysis of PT for quadriceps (PT-Q) and hamstrings (PT-H) generally showed that the goalkeepers and central midfielders had lower strength levels compared to other playing positions. In the case of PT-H and hamstring/quadricep (H/Q) peak torque ratios, statistically significant differences were also noted for the legs, where mean values noted for the dominant leg were higher than for the non-dominant leg. For TW for quadriceps (TW-Q) and hamstrings (TW-H), statistically significant differences were noted only between playing positions. TW-Q values for goalkeepers were lower than for central defenders and external midfielders. TW-H values for goalkeepers were lower than for central midfielders, central defenders and external midfielders. This study showed that specific functional activity of players in individual positions on the field influences the varied profile of isokinetic strength performance.
Howard, William; Burgess, Jonathan; Vrhovnik, Borut; Stringer, Christian; Choy, Sherrie T; Marsden, Jonathan F; Gedikoglou, Ingrid A; Shum, Gary L
2017-04-01
To determine the differences in the dynamic control ratio of the glenohumeral joint rotators, during internal rotation at 20° and 60° of humeral elevation in the scapular plan. Dynamic control ratio (DCR) is defined as the ratio between eccentric action of the lateral rotators and the concentric action of the medial rotators. A cross-sectional laboratory study. Thirty asymptomatic participants (men n=14, women n=16, mean age=29.4±8.9years, BMI: 24.1±5.4) were tested. Peak torque generated by the concentric action of the MR and the eccentric action of the LR of the shoulder joint and the DCR were evaluated on the dominant arm using an isokinetic dynamometer at 20° and 60° of humeral elevation at a speed of 20°/s. There was a significant decrease in the DCR at 60° humeral elevation when compared to 20° humeral elevation (p<0.05). This decrease was due to the significant decrease in eccentric peak torques at 60° humeral elevation when compared to 20° (p<0.05). However, there was no significant difference in the concentric peak torques between 20° and 60° (p>0.05). The significant decrease in the DCR as a consequence of a decrease in the eccentric peak torque of the LR when the humerus is in a more elevated position suggests that the introduction of humeral elevation can be used as a progression for improving the eccentric action of the shoulder LR and subsequently the dynamic control of the shoulder. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Yeung, S S; Ng, G Y
2000-06-01
Manual lifting is a frequent cause of back injury, and there is no evidence as to which training mode can provide the best training effect for lifting performance and muscle force. The purpose of this study was to examine the effects of a squat lift training and a free weight muscle training program on the maximum lifting load and isokinetic peak torque in subjects without known neuromuscular or musculoskeletal impairments. Thirty-six adults (20 male, 16 female) without known neuromuscular or musculoskeletal impairments participated. The subjects' mean age was 21.25 years (SD=1.16, range=20-24). Subjects were divided into 3 groups. Subjects in group 1 (n=12) performed squat lift training. Subjects in group 2 (n=12) participated in free weight resistance training of their shoulder abductors, elbow flexors, knee extensors and trunk extensors. Subjects in group 3 (n=12) served as controls. The maximum lifting load and isokinetic peak torques of the trunk extensors, knee extensors, elbow flexors, and shoulder abductors of each subject were measured before and after the study. Training was conducted on alternate days for 4 weeks, with an initial load of 80% of each subject's maximum capacity and with the load increased by 5% weekly. All groups were comparable for all measured variables before the study. After 4 weeks, subjects in groups 1 and 2 demonstrated more improvement in maximum lifting load and isokinetic peak torque of the back extensors compared with the subjects in group 3, but the 2 training groups were not different. The findings demonstrate that both squat lift and free weight resistance training are equally effective in improving the lifting load and isokinetic back extension performance of individuals without impairments.
Hamstring Strength and Morphology Progression after Return to Sport from Injury
Sanfilippo, Jennifer; Silder, Amy; Sherry, Marc A; Tuite, Michael J; Heiderscheit, Bryan C
2012-01-01
Hamstring strain re-injury rates can reach 30% within the initial two weeks following return to sport (RTS). Incomplete recovery of strength may be a contributing factor. However, relative strength of the injured and unaffected limbs at RTS is currently unknown. PURPOSE: Characterize hamstring strength and morphology at the time of RTS and six months later. METHODS: Twenty-five athletes that experienced an acute hamstring strain injury participated, following completion of a controlled rehabilitation program. Bilateral isokinetic strength testing and magnetic resonance imaging (MRI) were performed at RTS and 6-months later. Strength (knee flexion peak torque, work, angle of peak torque) and MRI (muscle and tendon volumes) measures were compared between limbs and over time using repeated measures ANOVA. RESULTS: The injured limb showed a peak torque deficit of 9.6% compared to the uninjured limb at RTS (60°/s, p<0.001), but not 6-months following. The knee flexion angle of peak torque decreased over time for both limbs (60°/s, p<0.001). MRI revealed that 20.4% of the muscle cross-sectional area showed signs of edema at RTS with full resolution by the 6-month follow-up. Tendon volume of the injured limb tended to increase over time (p=0.108), while muscle volume decreased 4–5% in both limbs (p<0.001). CONCLUSION: Residual edema and deficits in isokinetic knee flexion strength were present at RTS, but resolved during the subsequent six months. This occurred despite MRI evidence of scar tissue formation (increased tendon volume) and muscle atrophy, suggesting that neuromuscular factors may contribute to the return of strength. PMID:23059864
Williams, N; Coburn, J; Gillum, T
2015-11-01
The aim of this paper was to determine if two different warm-up protocols differently affect torque of the quadriceps and hamstrings, and electromyography (EMG) output of the rectus femoris (RF) and vastus lateralis (VL) when completing 30 maximal leg extensions and curls. Twenty-one healthy male (N.=8) and female (N.=13) subjects volunteered to participate in a familiarization session and three testing sessions. The three testing sessions control, dynamic, and static were completed in a counterbalanced order on non-consecutive days. First, subjects warmed-up on a treadmill for five minutes before completing six dynamic movements, six static-stretches, or no stretches. They then rested for five minutes before completing 30 maximal leg extensions and curls at a speed of 60 s-1. A significant decrease in quadriceps torque output over time was determined for the dynamic protocol when compared to the control (P<0.01) and static (P<0.05) protocols. A significant decrease was found in peak quadriceps torque for the dynamic protocol (P<0.01) when compared to the static, and a significant increase was found for the static protocol (P<0.05) when compared to the control. A significant decrease in average quadriceps torque was found for the dynamic protocol when compared to the static (P<0.05) and control (P<0.01) protocols. No difference was found in hamstring torque or EMG output of the RF and VL. Short duration static-stretching has the ability to increase peak and average torque of the leg extensors, while some types of anaerobic exercise involving maximal contractions to fatigue may be hindered by performing dynamic movements as part of the warm-up.
Dynamic fatigue performance of implant-abutment assemblies with different tightening torque values.
Xia, Dandan; Lin, Hong; Yuan, Shenpo; Bai, Wei; Zheng, Gang
2014-01-01
Implant-abutment assemblies are usually subject to long-term cyclic loading. To evaluate the dynamic fatigue performance of implant-abutment assemblies with different tightening torque values, thirty implant-abutment assemblies (Zimmer Dental, Carlsbad, CA, USA) were randomly assigned to three tightening groups (24 Ncm; 30 Ncm; 36 Ncm), each consisted of 10 implants. Five specimens from each group were unscrewed, and their reverse torque values recorded. The remaining specimens were subjected to a load between 30 N~300 N at a loading frequency of 15 Hz for 5 × 10(6) cycles. After fatigue tests, residual reverse torque values were recorded if available. In the 24 Ncm tightening group, all the implants fractured at the first outer thread of the implant after fatigue loading, with fatigue crack propagation at the fractured surface showed by SEM observation. For the 30 Ncm and 36 Ncm tightening groups, a statistical significant difference (p<0.05) between the unloaded and loaded groups was revealed. Compared with the unloaded specimens, the specimens went through fatigue loading had decreased reverse torque values. It was demonstrated that insufficient torque will lead to poor fatigue performance of dental implant-abutment assemblies and abutment screws should be tightened to the torque recommended by the manufacturer. It was also concluded that fatigue loading would lead to preload loss.
The overuse of the implant motor: effect on the output torque in overloading condition.
Lee, Du-Hyeong; Cho, Sung-Am; Lee, Cheong-Hee; Lee, Kyu-Bok
2015-06-01
The overloading of the motor affects its performance. The output torque of the implant motor under overloading condition has not been reported. The purpose of this study was to determine the reliability and the tendency of the output torque when an implant motor is consecutively used. Three implant motors were evaluated: SurgicXT/X-SG20L (NSK), INTRAsurg300/CL3-09 (KaVo), and XIP10/CRB26LX (Saeshin). The output torque was measured using an electronic torque gauge fixed with jigs. For the 40 and 50 Ncm torque settings, 300 measurements were taken at 30 rpm. Repeated measures of analysis of variance (ANOVA) and one-way ANOVA were used to compare the torque values within each group and between the groups. As repeating measures, the output torque values decreased gradually compared with the baseline. In within-group analysis, the different torque value from the first measurement appeared earliest in NSK motor, followed in order by Saeshin and KaVo motors. NSK motor showed a different torque decrease between 40 and 50 Ncm settings (p < .05). Intergroup analysis revealed Saeshin motor to have the least deviation from the baseline, followed by KaVo motor. NSK motor had the most inconsistent torque at the 6, 8, 9, and 10 repeat counts (p < .05). The actual torque decreases when the surgical motor is continuously used. The NSK motor showed more significant decreases in torque than KaVo and Saeshin motors in overloading condition. © 2014 Wiley Periodicals, Inc.
Arshad, Mahnaz; Mahgoli, Hosseinali; Payaminia, Leila
To evaluate the effect of repeated screw joint closing and opening cycles and cyclic loading on abutment screw removal torque and screw thread morphology using scanning electron microscopy (SEM). Three groups (n = 10 in each group) of implant-abutment-abutment screw assemblies were created. There were also 10 extra abutment screws as new screws in group 3. The abutment screws were tightened to 12 Ncm with an electronic torque meter; then they were removed and removal torque values were recorded. This sequence was repeated 5 times for group 1 and 15 times for groups 2 and 3. The same screws in groups 1 and 2 and the new screws in group 3 were then tightened to 12 Ncm; this was also followed by screw tightening to 30 Ncm and retightening to 30 Ncm 15 minutes later. Removal torque measurements were performed after screws were subjected to cyclic loading (0.5 × 10⁶ cycles; 1 Hz; 75 N). Moreover, the surface topography of one screw from each group before and after cyclic loading was evaluated with SEM and compared with an unused screw. All groups exhibited reduced removal torque values in comparison to insertion torque in each cycle. However, there was a steady trend of torque loss in each group. A comparison of the last cycle of the groups before loading showed significantly greater torque loss value in the 15th cycle of groups 2 and 3 compared with the fifth cycle of group 1 (P < .05). Nonetheless, torque loss values after loading were not shown to be significantly different from each other. Using a new screw could not significantly increase the value of removal torque. It was concluded that restricting the amount of screw tightening is more important than replacing the screw with a new one when an abutment is definitively placed.
Reliability and validity of the closed kinetic chain upper extremity stability test.
Lee, Dong-Rour; Kim, Laurentius Jongsoon
2015-04-01
[Purpose] The purpose of this study was to examine the reliability and validity of the Closed Kinetic Chain Upper Extremity Stability (CKCUES) test. [Subjects and Methods] A sample of 40 subjects (20 males, 20 females) with and without pain in the upper limbs was recruited. The subjects were tested twice, three days apart to assess the reliability of the CKCUES test. The CKCUES test was performed four times, and the average was calculated using the data of the last 3 tests. In order to test the validity of the CKCUES test, peak torque of internal/external shoulder rotation was measured using an isokinetic dynamometer, and maximum grip strength was measured using a hand dynamometer, and their Pearson correlation coefficients with the average values of the CKCUES test were calculated. [Results] The reliability of the CKCUES test was very high (ICC=0.97). The correlations between the CKCUES test and maximum grip strength (r=0.78-0.79), and the peak torque of internal/external shoulder rotation (r=0.87-0.94) were high indicating its validity. [Conclusion] The reliability and validity of the CKCUES test were high. The CKCUES test is expected to be used for clinical tests on upper limb stability at low price.
[Isokinetic profile of knee flexors and extensors in a population of rugby players].
Larrat, E; Kemoun, G; Carette, P; Teffaha, D; Dugue, B
2007-06-01
We aimed to assess the isokinetic profile of the flexor and extensor muscles of the knee within a population of rugby players. This was a descriptive study. The rugby players underwent bilateral isokinetic assessment of knee flexion and extension on a CON-TREX MJ isokinetic dynamometer functioning at four angular frequencies - 90, 120, 180 and 240 degrees/s - in a concentric manner. The isokinetic parameters were peak torque, mean power, and mean work in relation to weight and femoral bicep: quadriceps ratio. The population included 16 "Federal 1" (semi-professional) rugby players with mean age 25 years (range 20-33 years). The players were divided into two groups: "forward" players (props, hookers, second line, third line) and "back" players (scrum, inside, center, wing, tail). The values of the isokinetic parameters did not reveal use of a preferred limb. Consequently, peak torque and mean power were higher in forward players than back players, whereas back players showed a higher relative power throughout the isokinetic test. Among rugby players, forward and back players showed differences in several isokinetic parameters. Accurate knowledge of the equilibrium between the knee's effector muscles is important for stability of the joint, to not only minimize articular accidents but also pinpoint force imbalances, thereby preventing muscular lesions during the sports season.
Lower-extremity isokinetic strength profiling in professional rugby league and rugby union.
Brown, Scott R; Brughelli, Matt; Griffiths, Peter C; Cronin, John B
2014-03-01
While several studies have documented isokinetic knee strength in junior and senior rugby league players, investigations of isokinetic knee and hip strength in professional rugby union players are limited. The purpose of this study was to provide lower-extremity strength profiles and compare isokinetic knee and hip strength of professional rugby league and rugby union players. 32 professional rugby league and 25 professional rugby union players. Cross-sectional analysis. Isokinetic dynamometry was used to evaluate peak torque and strength ratios of the dominant and nondominant legs during seated knee-extension/ flexion and supine hip-extension/flexion actions at 60°/s. Forwards from both codes were taller and heavier and had a higher body-mass index than the backs of each code. Rugby union forwards produced significantly (P < .05) greater peak torque during knee flexion in the dominant and nondominant legs (ES = 1.81 and 2.02) compared with rugby league forwards. Rugby league backs produced significantly greater hip-extension peak torque in the dominant and nondominant legs (ES = 0.83 and 0.77) compared with rugby union backs. There were no significant differences in hamstring-to-quadriceps ratios between code, position, or leg. Rugby union forwards and backs produced significantly greater knee-flexion-to-hip-extension ratios in the dominant and nondominant legs (ES = 1.49-2.26) than rugby union players. It seems that the joint torque profiles of players from rugby league and union codes differ, which may be attributed to the different demands of each code.
The Influence of Glove Type on Simulated Wheelchair Racing Propulsion: A Pilot Study.
Rice, I; Dysterheft, J; Bleakney, A W; Cooper, R A
2016-01-01
Our purpose was to examine the influence of glove type on kinetic and spatiotemporal parameters at the handrim in elite wheelchair racers. Elite wheelchair racers (n=9) propelled on a dynamometer in their own racing chairs with a force and moment sensing wheel attached. Racers propelled at 3 steady state speeds (5.36, 6.26 & 7.60 m/s) and performed one maximal effort sprint with 2 different glove types (soft & solid). Peak resultant force, peak torque, impulse, contact angle, braking torque, push time, velocity, and stroke frequency were recorded for steady state and sprint conditions. Multiple nonparametric Wilcoxon matched pair's tests were used to detect differences between glove types, while effect sizes were calculated based on Cohen's d. During steady state trials, racers propelled faster, using more strokes and larger contact angle, while applying less impulse with solid gloves compared to soft gloves. During the sprint condition, racers achieved greater top end velocities, applying larger peak force, with less braking torque with solid gloves compared to soft gloves. Use of solid gloves may provide some performance benefits to wheelchair racers during steady state and top end velocity conditions. © Georg Thieme Verlag KG Stuttgart · New York.
Serefoglu, Abdullah; Sekir, Ufuk; Gür, Hakan; Akova, Bedrettin
2017-01-01
The aim of this study was to investigate if static and dynamic stretching exercises of the knee muscles (quadriceps and hamstring muscles) have any effects on concentric and eccentric isokinetic peak torques and electromyographic amplitudes (EMG) of the antagonist muscles. Twenty healthy male athletes (age between 18-30 years) voluntarily participated in this study. All of the subjects visited the laboratory to complete the following intervention in a randomized order on 5 separate days; (a) non-stretching (control), (b) static stretching of the quadriceps muscles, (c) static stretching of the hamstring muscles, (d) dynamic stretching of the quadriceps muscles, and (e) dynamic stretching of the hamstring muscles. Static stretching exercises either for the quadriceps or the hamstring muscles were carried out at the standing and sitting positions. Subjects performed four successive repetitions of each stretching exercises for 30 seconds in both stretching positions. Similar to static stretching exercises two different stretching modes were designed for dynamic stretching exercises. Concentric and eccentric isokinetic peak torque for the non-stretched antagonist quadriceps or hamstring muscles at angular velocities of 60°/sec and 240°/sec and their concurrent electromyographic (EMG) activities were measured before and immediately after the intervention. Isokinetic peak torques of the non-stretched agonist hamstring and quadriceps muscles did not represent any significant (p > 0.05) differences following static and dynamic stretching of the antagonist quadriceps and hamstring muscles, respectively. Similarly, the EMG activities of the agonist muscles exhibited no significant alterations (p > 0.05) following both stretching exercises of the antagonist muscles. According to the results of the present study it is possible to state that antagonist stretching exercises either in the static or dynamic modes do not affect the isokinetic peak torques and the EMG activities of the non-stretched agonist quadriceps or hamstring muscles. Key points The effects of dynamic stretching of the antagonist muscles on strength performance are unknown. We showed that both static and dynamic stretching of the antagonist muscle does not influence strength and EMG activities in the agonist muscles. Further research should focus on the effects of antagonist stretching using other techniques like PNF or ballistic stretching and/or different volumes of stretching. PMID:28344445
Aggregate Mesenchymal Stem Cell Delivery Ameliorates the Regenerative Niche for Muscle Repair.
Ruehle, Marissa A; Stevens, Hazel Y; Beedle, Aaron M; Guldberg, Robert E; Call, Jarrod A
2018-05-18
Duchenne muscular dystrophy (DMD) is a severe muscle wasting disease due to the absence of the dystrophin protein from the muscle cell membrane which renders the muscle susceptible to continuous damage. In DMD patients, muscle weakness, together with cycles of degeneration/regeneration and replacement with non-contractile tissue, limit mobility and lifespan. Since the loss of dystrophin result in loss of polarity and a reduction in the number of self-renewing satellite cells, it is postulated that these patients could achieve an improved quality of life if delivered cells could restore satellite cell function. In this study we used both an established myotoxic injury model in wildtype (WT) mice and mdx mice alone (spontaneous muscle damage). Single (SC) and aggregated (AGG) mesenchymal stem cells (MSCs) were injected into the gastrocnemius muscles 4 hours after injury (WT mice). The recovery of peak isometric torque was longitudinally assessed over 5 weeks, with earlier takedowns for histological assessment of healing (fiber cross section area and central nucleation) and MSC retention. AGG-treated WT mice had significantly greater torque recovery at day 14 than SC or saline-treated mice and a greater CSA at day 10, compared to SC/saline. AGG-treated mdx mice had a greater peak isometric torque compared to SC/saline. In vitro immunomodulatory factor secretion of AGG-MSCs was higher than SC-MSCs for all tested growth factors with the largest difference observed in hepatocyte growth factor (HGF). Future studies are necessary to pair immunomodulatory factor secretion with functional attributes, to better predict the potential therapeutic value of MSC treatment modalities. This article is protected by copyright. All rights reserved.
Yanagisawa, O; Otsuka, S; Fukubayashi, T
2014-02-01
To evaluate the effects of cooling between exercise sessions on intramuscular water movement and muscle performance, the lower extremities of nine untrained men were assigned to either a cooling protocol (20-min water immersion, 15 °C) or a noncooling protocol. Each subject performed two exercise sessions involving maximal concentric knee extension and flexion (three repetitions, 60°/s; followed by 50 repetitions, 180°/s). The peak torque at 60°/s and total work, mean power, and decrease rate of torque value at 180°/s were evaluated. Axial magnetic resonance diffusion-weighted images of the mid-thigh were obtained before and after each exercise session. Apparent diffusion coefficient (ADC) values for the quadriceps and hamstrings were calculated for evaluating intramuscular water movement. Both groups exhibited significantly increased ADC values for the quadriceps and hamstrings after each exercise session. These ADC values returned to the pre-exercise level after water immersion. No significant difference was observed in muscle performance from first exercise session to the next in either group, except for increased total work and mean power in knee flexion in the cooled group. Cooling intervention between exercise sessions decreased exercise-induced elevation of intramuscular water movement and had some beneficial effects on muscle endurance of knee flexors, but not knee extensors. © 2012 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Reliability of metatarsophalangeal and ankle joint torque measurements by an innovative device.
Man, Hok-Sum; Leung, Aaron Kam-Lun; Cheung, Jason Tak-Man; Sterzing, Thorsten
2016-07-01
The toe flexor muscles maintain body balance during standing and provide push-off force during walking, running, and jumping. Additionally, they are important contributing structures to maintain normal foot function. Thus, weakness of these muscles may cause poor balance, inefficient locomotion and foot deformities. The quantification of metatarsophalangeal joint (MPJ) stiffness is valuable as it is considered as a confounding factor in toe flexor muscles function. MPJ and ankle joint stiffness measurement is still largely depended on manual skills as current devices do not have good control on alignment, angular joint speed and displacement during measurement. Therefore, this study introduces an innovative dynamometer and protocol procedures for MPJ and ankle Joint torque measurement with precise and reliable foot alignment, angular joint speed and displacement control. Within-day and between-day test-retest experiments on MPJ and ankle joint torque measurement were conducted on ten and nine healthy male subjects respectively. The mean peak torques of MPJ and ankle joint of between-day and within-day measurement were 1.50±0.38Nm/deg and 1.19±0.34Nm/deg. The corresponding torques of the ankle joint were 8.24±2.20Nm/deg and 7.90±3.18Nm/deg respectively. Intraclass-correlation coefficients (ICC) of averaged peak torque of both joints of between-day and within-day test-retest experiments were ranging from 0.91 to 0.96, indicating the innovative device is systematic and reliable for the measurements and can be used for multiple scientific and clinical purposes. Copyright © 2016 Elsevier B.V. All rights reserved.
Helgeson, Melvin D; Kang, Daniel G; Lehman, Ronald A; Dmitriev, Anton E; Luhmann, Scott J
2013-08-01
There is currently no reliable technique for intraoperative assessment of pedicle screw fixation strength and optimal screw size. Several studies have evaluated pedicle screw insertional torque (IT) and its direct correlation with pullout strength. However, there is limited clinical application with pedicle screw IT as it must be measured during screw placement and rarely causes the spine surgeon to change screw size. To date, no study has evaluated tapping IT, which precedes screw insertion, and its ability to predict pedicle screw pullout strength. The objective of this study was to investigate tapping IT and its ability to predict pedicle screw pullout strength and optimal screw size. In vitro human cadaveric biomechanical analysis. Twenty fresh-frozen human cadaveric thoracic vertebral levels were prepared and dual-energy radiographic absorptiometry scanned for bone mineral density (BMD). All specimens were osteoporotic with a mean BMD of 0.60 ± 0.07 g/cm(2). Five specimens (n=10) were used to perform a pilot study, as there were no previously established values for optimal tapping IT. Each pedicle during the pilot study was measured using a digital caliper as well as computed tomography measurements, and the optimal screw size was determined to be equal to or the first size smaller than the pedicle diameter. The optimal tap size was then selected as the tap diameter 1 mm smaller than the optimal screw size. During optimal tap size insertion, all peak tapping IT values were found to be between 2 in-lbs and 3 in-lbs. Therefore, the threshold tapping IT value for optimal pedicle screw and tap size was determined to be 2.5 in-lbs, and a comparison tapping IT value of 1.5 in-lbs was selected. Next, 15 test specimens (n=30) were measured with digital calipers, probed, tapped, and instrumented using a paired comparison between the two threshold tapping IT values (Group 1: 1.5 in-lbs; Group 2: 2.5 in-lbs), randomly assigned to the left or right pedicle on each specimen. Each pedicle was incrementally tapped to increasing size (3.75, 4.00, 4.50, and 5.50 mm) until the threshold value was reached based on the assigned group. Pedicle screw size was determined by adding 1 mm to the tap size that crossed the threshold torque value. Torque measurements were recorded with each revolution during tap and pedicle screw insertion. Each specimen was then individually potted and pedicle screws pulled out "in-line" with the screw axis at a rate of 0.25 mm/sec. Peak pullout strength (POS) was measured in Newtons (N). The peak tapping IT was significantly increased (50%) in Group 2 (3.23 ± 0.65 in-lbs) compared with Group 1 (2.15 ± 0.56 in-lbs) (p=.0005). The peak screw IT was also significantly increased (19%) in Group 2 (8.99 ± 2.27 in-lbs) compared with Group 1 (7.52 ± 2.96 in-lbs) (p=.02). The pedicle screw pullout strength was also significantly increased (23%) in Group 2 (877.9 ± 235.2 N) compared with Group 1 (712.3 ± 223.1 N) (p=.017). The mean pedicle screw diameter was significantly increased in Group 2 (5.70 ± 1.05 mm) compared with Group 1 (5.00 ± 0.80 mm) (p=.0002). There was also an increased rate of optimal pedicle screw size selection in Group 2 with 9 of 15 (60%) pedicle screws compared with Group 1 with 4 of 15 (26.7%) pedicle screws within 1 mm of the measured pedicle width. There was a moderate correlation for tapping IT with both screw IT (r=0.54; p=.002) and pedicle screw POS (r=0.55; p=.002). Our findings suggest that tapping IT directly correlates with pedicle screw IT, pedicle screw pullout strength, and optimal pedicle screw size. Therefore, tapping IT may be used during thoracic pedicle screw instrumentation as an adjunct to preoperative imaging and clinical experience to maximize fixation strength and optimize pedicle "fit and fill" with the largest screw possible. However, further prospective, in vivo studies are necessary to evaluate the intraoperative use of tapping IT to predict screw loosening/complications. Published by Elsevier Inc.
Paek, Janghyun; Woo, Yi-Hyung; Kim, Hyeong-Seob; Pae, Ahran; Noh, Kwantae; Lee, Hyeonjong; Kwon, Kung-Rock
2016-12-01
The aim of this study was to determine the stability of computer-aided design and manufacturing (CAD/CAM) and prefabricated abutment by measuring removal torque before and after cyclic loading. Three types of fixture and 2 types of abutments were used. Removable torque was measured after cyclic loading for 5000 cycles between 25 and 250 N for each group. The same procedure was performed twice. First, removal torque values (Newton centimeter) were measured for stock versus custom abutments as follows: group 1: 27.17 versus 26.67, group 2: 26.27 versus 26.33, and group 3: 37.33 versus 36.67. Second removal torque values (Newton centimeter) were also measured: group 1: 23 versus 23.5, group 2: 22.5 versus 22.33, and group 3: 32.67 versus 32.5. There was no significant difference between the stock and custom abutments in either the first or second removal torque values and also no significant difference among initial tightening torque, first or second removal torque (P > 0.05). With precise control of CAD/CAM abutments, good screw joint stability can be achieved.
Hip joint torques during the golf swing of young and senior healthy males.
Foxworth, Judy L; Millar, Audrey L; Long, Benjamin L; Way, Michael; Vellucci, Matthew W; Vogler, Joshua D
2013-09-01
Descriptive, laboratory study. To compare the 3-D hip torques during a golf swing between young and senior healthy male amateur golfers. The secondary purpose was to compare the 3-D hip joint torques between the trail leg and lead leg. The generation of hip torques from the hip musculature is an important aspect of the golf swing. Golf is a very popular activity, and estimates of hip torques during the golf swing have not been reported. Twenty healthy male golfers were divided into a young group (mean ± SD age, 25.1 ± 3.1 years) and a senior group (age, 56.9 ± 4.7 years). All subjects completed 10 golf swings using their personal driver. A motion capture system and force plates were used to obtain kinematic and kinetic data. Inverse dynamic analyses were used to calculate 3-D hip joint torques of the trail and lead limbs. Two-way analyses of covariance (group by leg), with club-head velocity as a covariate, were used to compare peak hip torques between groups and limbs. Trail-limb hip external rotator torque was significantly greater in the younger group compared to the senior group, and greater in the trail leg versus the lead leg. When adjusting for club-head velocity, young and senior healthy male amateur golfers generated comparable hip torques during a golf swing, with the exception of the trail-limb hip external rotator torque. The largest hip torque found was the trail-limb hip extensor torque.
Boling, Michelle C; Padua, Darin A; Alexander Creighton, R
2009-01-01
Individuals suffering from patellofemoral pain have previously been reported to have decreased isometric strength of the hip musculature; however, no researchers have investigated concentric and eccentric torque of the hip musculature in individuals with patellofemoral pain. To compare concentric and eccentric torque of the hip musculature in individuals with and without patellofemoral pain. Case control. Research laboratory. Twenty participants with patellofemoral pain (age = 26.8 +/- 4.5 years, height = 171.8 +/- 8.4 cm, mass = 72.4 +/- 16.8 kg) and 20 control participants (age = 25.6 +/- 2.8 years, height = 169.5 +/- 8.9 cm, mass = 70.0 +/- 16.9 kg) were tested. Volunteers with patellofemoral pain met the following criteria: knee pain greater than or equal to 3 cm on a 10-cm visual analog scale, insidious onset of symptoms not related to trauma, pain with palpation of the patellar facets, and knee pain during 2 of the following activities: stair climbing, jumping or running, squatting, kneeling, or prolonged sitting. Control participants were excluded if they had a prior history of patellofemoral pain, knee surgery in the past 2 years, or current lower extremity injury that limited participation in physical activity. Concentric and eccentric torque of the hip musculature was measured on an isokinetic dynamometer. All volunteers performed 5 repetitions of each strength test. Separate multivariate analyses of variance were performed to compare concentric and eccentric torque of the hip extensors, abductors, and external rotators between groups. Average and peak concentric and eccentric torque of the hip extensors, abductors, and external rotators. Torque measures were normalized to the participant's body weight multiplied by height. The patellofemoral pain group was weaker than the control group for peak eccentric hip abduction torque (F(1,38) = 6.630, P = .014), and average concentric (F(1,38) = 4.156, P = .048) and eccentric (F(1,38) = 4.963, P = .032) hip external rotation torque. The patellofemoral pain group displayed weakness in eccentric hip abduction and hip external rotation, which may allow for increased hip adduction and internal rotation during functional movements.
Knee strength ratios in competitive female athletes
Murawa, Michal; Mackala, Krzysztof; Dworak, Lechoslaw Bogdan
2018-01-01
Knee strength ratios are related to the movement patterns, sport-specific training and knee injuries in athletes. The purpose of this study was to determine the ratios in the concentric isokinetic strength of the hamstrings and quadriceps and the isometric strength of the knee extensors. In female basketball players (n = 14) and female volleyball players (n = 12) were evaluated: the hamstrings to quadriceps peak torque ratio (H/Q) and side-to-side peak torque ratio (TR) for hamstrings and quadriceps; the ratio of the maximal bilateral strength to the summed maximal unilateral strength (B/U) and side-to-side maximal strength ratio (SR) for knee extensors. For the H/Q values, a 2 × 2 × 3 mixed-factorial analysis of variance and Bonferroni post hoc test were computed. The H/Q values increased from 48.0 (3.9)% at 60°/s to 70.4 (7.9)% at 300°/s. Furthermore, there were significant differences in the H/Q values between 300°/s and 180°/s, 300°/s and 60°/s in basketball and volleyball athletes, and between 180°/s and 60°/s only in basketball athletes (p < .05). Significantly higher H/Q results at 60°/s demonstrated basketball players than volleyball players (p < .05). Differences in the TR and SR mean values ranged from 4.4% to 8.6% and indicated no significant side-to-side strength deficits (p > .05). In both groups, greater isometric strength developed bilaterally was found (B/U > 100%). The findings revealed the magnitude of knee strength ratios in female athletes determined by sport-specific movements in basketball and volleyball. This study highlighted the importance of the bilateral strength deficit and muscular balance between the hamstrings and quadriceps in basketball and volleyball athletes in activities related to their movement patterns and specific training. PMID:29315348
DiZio, Paul; Lackner, James R.
2013-01-01
We have previously shown that the Coriolis torques that result when an arm movement is performed during torso rotation do not affect movement trajectory. Our purpose in the present study was to examine whether torso motion-induced Coriolis and other interaction torques are counteracted during a turn and reach (T&R) movement when the effective mass of the hand is augmented, and whether the dominant arm has an advantage in coordinating intersegmental dynamics as predicted by the dynamic dominance hypothesis (Sainburg RL. Exp Brain Res 142: 241–258, 2002). Subjects made slow and fast T&R movements in the dark to just extinguished targets with either arm, while holding or not holding a 454-g object. Movement endpoints were equally accurate at both speeds, with either hand, and in both weight conditions, but subjects tended to angularly undershoot and produce more variable endpoints for targets requiring greater torso rotation. There were no changes in endpoint accuracy or trajectory deviation over repeated movements. The dominant right arm was more stable in its control of trajectory direction across targets, whereas the nondominant left arm had an improved ability to stop accurately on the target for higher levels of interaction torques. The trajectories to more eccentric targets were straighter when performed at higher speeds but slightly more deviated when subjects held the weight. Subjects did not slow their torso velocity or change the timing of the arm and torso velocities when holding the weight, although there was a slight decrease in their hand velocity relative to the torso. The delay between the onsets of torso and finger movements was almost twice as large for the right arm than the left, suggesting the right arm was better able to account for torso rotation in the arm movement. Holding the weight increased the peak Coriolis torque by 40% at the shoulder and 45% at the elbow and, for the most eccentric target, increased the peak net torque by 12% at the shoulder and 34% at the elbow. In accordance with Sainburg's dynamic dominance hypothesis, the right arm exhibited an advantage for coordinating intersegmental dynamics, showing a more stable finger velocity in relation to the torso across targets, decreasing error variability with movement speed, and more synchronized peaks of finger relative and torso angular velocities in conditions with greater joint torque requirements. The arm used had little effect on the movement path and the magnitude of the joint torques in any of the conditions. These results indicate that compensations for forthcoming Coriolis torque variations take into account the dynamic properties of the body and of external objects, as well as the planned velocities of the torso and arm. PMID:23803330
Pigeon, Pascale; Dizio, Paul; Lackner, James R
2013-09-01
We have previously shown that the Coriolis torques that result when an arm movement is performed during torso rotation do not affect movement trajectory. Our purpose in the present study was to examine whether torso motion-induced Coriolis and other interaction torques are counteracted during a turn and reach (T&R) movement when the effective mass of the hand is augmented, and whether the dominant arm has an advantage in coordinating intersegmental dynamics as predicted by the dynamic dominance hypothesis (Sainburg RL. Exp Brain Res 142: 241-258, 2002). Subjects made slow and fast T&R movements in the dark to just extinguished targets with either arm, while holding or not holding a 454-g object. Movement endpoints were equally accurate at both speeds, with either hand, and in both weight conditions, but subjects tended to angularly undershoot and produce more variable endpoints for targets requiring greater torso rotation. There were no changes in endpoint accuracy or trajectory deviation over repeated movements. The dominant right arm was more stable in its control of trajectory direction across targets, whereas the nondominant left arm had an improved ability to stop accurately on the target for higher levels of interaction torques. The trajectories to more eccentric targets were straighter when performed at higher speeds but slightly more deviated when subjects held the weight. Subjects did not slow their torso velocity or change the timing of the arm and torso velocities when holding the weight, although there was a slight decrease in their hand velocity relative to the torso. The delay between the onsets of torso and finger movements was almost twice as large for the right arm than the left, suggesting the right arm was better able to account for torso rotation in the arm movement. Holding the weight increased the peak Coriolis torque by 40% at the shoulder and 45% at the elbow and, for the most eccentric target, increased the peak net torque by 12% at the shoulder and 34% at the elbow. In accordance with Sainburg's dynamic dominance hypothesis, the right arm exhibited an advantage for coordinating intersegmental dynamics, showing a more stable finger velocity in relation to the torso across targets, decreasing error variability with movement speed, and more synchronized peaks of finger relative and torso angular velocities in conditions with greater joint torque requirements. The arm used had little effect on the movement path and the magnitude of the joint torques in any of the conditions. These results indicate that compensations for forthcoming Coriolis torque variations take into account the dynamic properties of the body and of external objects, as well as the planned velocities of the torso and arm.
Acute effects of static stretching on peak and end-range hamstring-to-quadriceps functional ratios.
Sekir, Ufuk; Arabaci, Ramiz; Akova, Bedrettin
2015-10-18
To evaluate if static stretching influences peak and end-range functional hamstring-to-quadriceps (H/Q) strength ratios in elite women athletes. Eleven healthy female athletes in an elite competitive level participated to the study. All the participants fulfilled the static stretching or non-stretching (control) intervention protocol in a randomized design on different days. Two static unassisted stretching exercises, one in standing and one in sitting position, were used to stretch both the hamstring and quadriceps muscles during these protocols. The total time for the static stretching was 6 ± 1 min. The isokinetic peak torque measurements for the hamstring and quadriceps muscles in eccentric and concentric modes and the calculations for the functional H/Q strength ratios at angular velocities of 60°/s and 180°/s were made before (pre) and after (post) the control or stretching intervention. The strength measurements and functional strength ratio calculations were based during the entire- and end-range of knee extension. The pre-test scores for quadriceps and hamstring peak torque and end range values were not significantly different between the groups (P > 0.05). Subsequently, although the control group did not exhibit significant changes in quadriceps and hamstring muscle strength (P > 0.05), static stretching decreased eccentric and concentric quadriceps muscle strength at both the 60°/s and 180°/s test speeds (P < 0.01). Similarly, static stretching also decreased eccentric and concentric hamstring muscle strength at both the 60°/s and 180°/s test speeds (P < 0.01). On the other hand, when the functional H/Q strength ratios were taken into consideration, the pre-intervention values were not significant different between the groups both during the entire and end range of knee extension (P > 0.05). Furthermore, the functional H/Q strength ratios exhibited no significant alterations during the entire and end ranges of knee extension both in the static stretching or the control intervention (P > 0.05). According to our results, static stretching routine does not influence functional H/Q ratio. Athletes can confidently perform static stretching during their warm-up routines.
Acute effects of static stretching on peak and end-range hamstring-to-quadriceps functional ratios
Sekir, Ufuk; Arabaci, Ramiz; Akova, Bedrettin
2015-01-01
AIM: To evaluate if static stretching influences peak and end-range functional hamstring-to-quadriceps (H/Q) strength ratios in elite women athletes. METHODS: Eleven healthy female athletes in an elite competitive level participated to the study. All the participants fulfilled the static stretching or non-stretching (control) intervention protocol in a randomized design on different days. Two static unassisted stretching exercises, one in standing and one in sitting position, were used to stretch both the hamstring and quadriceps muscles during these protocols. The total time for the static stretching was 6 ± 1 min. The isokinetic peak torque measurements for the hamstring and quadriceps muscles in eccentric and concentric modes and the calculations for the functional H/Q strength ratios at angular velocities of 60°/s and 180°/s were made before (pre) and after (post) the control or stretching intervention. The strength measurements and functional strength ratio calculations were based during the entire- and end-range of knee extension. RESULTS: The pre-test scores for quadriceps and hamstring peak torque and end range values were not significantly different between the groups (P > 0.05). Subsequently, although the control group did not exhibit significant changes in quadriceps and hamstring muscle strength (P > 0.05), static stretching decreased eccentric and concentric quadriceps muscle strength at both the 60°/s and 180°/s test speeds (P < 0.01). Similarly, static stretching also decreased eccentric and concentric hamstring muscle strength at both the 60°/s and 180°/s test speeds (P < 0.01). On the other hand, when the functional H/Q strength ratios were taken into consideration, the pre-intervention values were not significant different between the groups both during the entire and end range of knee extension (P > 0.05). Furthermore, the functional H/Q strength ratios exhibited no significant alterations during the entire and end ranges of knee extension both in the static stretching or the control intervention (P > 0.05). CONCLUSION: According to our results, static stretching routine does not influence functional H/Q ratio. Athletes can confidently perform static stretching during their warm-up routines. PMID:26495249
Accuracy of dental torque wrenches.
Wood, James S; Marlow, Nicole M; Cayouette, Monica J
2015-01-01
The aim of this in vitro study was to compare the actual torque of 2 manual wrench systems to their stated (target) torque. New spring- (Nobel Biocare USA, LLC) and friction-style (Zimmer Dental, Inc.) manual dental torque wrenches, as well as spring torque wrenches that had undergone sterilization and clinical use, were tested. A calibrated torque gauge was used to compare actual torque to target torque values of 15 and 35 N/cm. Data were statistically analyzed via mixed-effects regression model with Bonferroni correction. At a target torque of 15 N/cm, the mean torque of new spring wrenches (13.97 N/cm; SE, 0.07 N/cm) was significantly different from that of used spring wrenches (14.94 N/cm; SE, 0.06 N/cm; P < 0.0001). However, the mean torques of new spring and new friction wrenches (14.10 N/cm; SE, 0.07 N/cm; P = 0.21) were not significantly different. For torque measurements calibrated at 35 N/cm, the mean torque of new spring wrenches (35.29 N/cm; SE, 0.10 N/cm) was significantly different (P < 0.0001) from the means of new friction wrenches (36.20 N/cm; SE, 0.08 N/cm) and used spring wrenches (36.45 N/cm; SE, 0.08 N/cm). Discrepancies in torque could impact the clinical success of screw-retained dental implants. It is recommended that torque wrenches be checked regularly to ensure that they are performing to target values.
Optical force and torque on a dielectric Rayleigh particle by a circular Airy vortex beam
NASA Astrophysics Data System (ADS)
Chen, Musheng; Huang, Sujuan; Shao, Wei; Liu, Xianpeng
2018-03-01
Optical force and torque exerted on the Rayleigh particles by tightly focused circularly polarized circular Airy vortex beams (CAVB) in the far field are studied in this paper. The relation between parameters of circularly polarized CAVB and the trapping properties is numerically analyzed based on Rayleigh models and the Debye diffraction theory. The results show that both the high refractive index and low refractive index particles can be fully stably trapped in three dimensions by circularly polarized CAVB. The parameters of circularly polarized CAVB greatly affect the optical force. The longitudinal and transverse gradient force increase with the increase of decay factor and scaling factor, and decrease with the increase of the radius of the first primary ring and topological charges. The positions of the longitudinal stable equilibrium move toward the high numerical aperture lens when the scaling factor and the radius of the primary ring increase. The trapping range is broadened with the decrease of scaling factor. The optical orbital torque (OOT) of circularly polarized CAVB has circular symmetry and remains positive or negative. With the increase of topological charges, the peak value of OOT first increases and then decreases after reaches a maximum. These results are useful for optical trapping, optical levitation and particle acceleration.
Beer, Andreas; Gahleitner, André; Holm, Anders; Birkfellner, Wolfgang; Homolka, Peter
2007-02-01
The aim of this study was to quantify the effect of adapted preparation on the insertion torque of self-tapping implants in cancellous bone. In adapted preparation, bone condensation - and thus, insertion torque - is controlled by changing the diameter of the drilling. After preparation of cancellous porcine vertebral bone with drills of 2.85, 3, 3.15 or 3.35 mm final diameters, Brånemark sytem Mk III implants (3.75 x 11.5 mm) were inserted in 141 sites. During implantation, the insertion torque was recorded. Prior to implant insertion, bone mineralization (bone mineral density (BMD)) was measured with dental quantative computed tomography. The BMD values measured at the implant position were correlated with insertion torque for varying bone condensation. Based on the average torque recorded during implant insertion into the pre-drilled canals with a diameter of 3 mm, torque increased by approximately 17% on reducing the diameter of the drill by 5% (to 2.85 mm). On increasing the diameter of the osteotomy to 3.15 mm (5%) or 3.35 mm (12%), torque values decreased by approximately 21% and 50%, respectively. The results demonstrate a correlation between primary stability (average insertion torque) and the diameter of the implant bed on using a screw-shaped implant. Thus, using an individualized bone mineralization-dependent drilling technique, optimized torque values could be achieved in all tested bone qualities with BMDs ranging from 330 to 500 mg/cm(3). The results indicate that using a bone-dependent drilling technique, higher torque values can also be achieved in poor bone using an individualized drilling resulting in higher bone condensation. As immediate function is dependent on primary stability (high insertion torque), this indicates that primary stability can be increased using a modified drilling technique in lesser mineralized bone.
Gait adaptations in patients with chronic posterior instability of the knee.
Hooper, D M; Morrissey, M C; Crookenden, R; Ireland, J; Beacon, J P
2002-03-01
A retrospective analysis was performed to assess gait in individuals with a long history of posterior knee instability. Descriptive study. There are few studies in the literature concerning evaluation of the biomechanics of the knee in patients with knee posterior instability. Nine individuals with posterior knee instability and a matched control group of uninjured subjects were tested in regards to knee kinematics and kinetics while walking and ascending and descending stairs. The mean follow up time for the individuals with posterior instability was 11.1 years. Individual satisfaction with the knee was measured by having participants complete the Flandry (also known as Hughston Clinic) self-assessment questionnaire. It was found that patients with knee posterior instability who indicated a higher level of satisfaction on the Flandry score walked in a manner that demonstrated greater peak knee extensor torque during stance phase, while less satisfied patients with knee posterior instability demonstrated lower peak knee extensor torque. There was a significant correlation between the self-assessment score and the peak knee extensor torque during level walking (P=0.003). During stair ascent and descent, patients with posterior instability averaged lower knee extensor torque and power than the control subjects, but those differences were only statistically significant in power while descending stairs (P=0.048). Individuals with chronic knee posterior instability modify their gait, and the adaptation can be predicted based upon the individuals self-assessment of their knee using the Flandry questionnaire. These data suggest that gait retraining may be a valuable addition to the traditional muscle strengthening programs, which are commonly used during conservative management of knee posterior instability.
Mechanical torque measurement for in vivo quantification of bone strength in the proximal femur.
Mueller, Marc Andreas; Hengg, Clemens; Hirschmann, Michael; Schmid, Denise; Sprecher, Christoph; Audigé, Laurent; Suhm, Norbert
2012-10-01
Bone strength determines fracture risk and fixation strength of osteosynthesis implants. In vivo, bone strength is currently measured indirectly by quantifying bone mineral density (BMD) which is however only one determinant of the bone's biomechanical competence besides the bone's macro- and micro-architecture and tissue related parameters. We have developed a measurement principle (DensiProbe™ Hip) for direct, mechanical quantification of bone strength within the proximal femur upon hip fracture fixation. Previous cadaver tests indicated a close correlation between DensiProbe™ Hip measurements, 3D micro-CT analysis and biomechanical indicators of bone strength. The goal of this study was to correlate DensiProbe™ Hip measurements with areal bone mineral density (BMD). Forty-three hip fracture patients were included in this study. Intraoperatively, DensiProbe™ Hip was inserted to the subsequent hip screw tip position within the femoral head. Peak torque to breakaway of local cancellous bone was registered. Thirty-seven patients underwent areal BMD measurements of the contralateral proximal femur. Failure of fixation was assessed radio graphically 6 and 12 weeks postoperatively. Peak torque and femoral neck BMD showed significant correlations (R=0.60, P=0.0001). In regression analysis, areal BMD explained 46% of femoral neck BMD variance in a quadratic relationship. Throughout the 12-week follow-up period, no failure of fixation was observed. DensiProbe™ Hip may capture variations of bone strength beyond areal BMD which are currently difficult to measure in vivo. A multicenter study will clarify if peak torque predicts fixation failure. Copyright © 2012 Elsevier Ltd. All rights reserved.
Removal torque of zirconia abutment screws under dry and wet conditions.
Nigro, Frederico; Sendyk, Claudio L; Francischone, Carlos Eduardo; Francischone, Carlos Eduardo
2010-01-01
The aim of this study was to verify whether screw abutment lubrication can generate higher preload values compared to non-lubricated screws, a titanium abutment was screwed onto an implant analog and scanned with the Procera System to generate 20 zirconia abutments. MKIII Brånemark implants were clamped to a precision torque device, and the abutments were distributed in dry and wet groups with 10 specimens each. In the wet groups, the inner threads of the implants were filled with artificial saliva. All abutments were fastened with a Torqtite screw under 32 Ncm. Ten detorque measurements were performed per group pushing the reverse button of the Torque controller soon after screw tightening with values registered. The mean detorque values were calculated and compared by a Student's t test (α=0.05). The wet condition presented significantly higher mean detorque than the dry condition (31.5 ± 1.2 versus 27.5 ± 1.5 Ncm, respectively; p=0.0000024). In conclusion, there was always a loss in the initial torque values when the removal torque was measured under both conditions. The wet condition presented higher mean torque than the dry condition. Better preload values were established in the wet group, suggesting that the abutment screw must be lubricated in saliva to avoid further loosening.
Sasaki, Shizuka; Chiba, Daisuke; Yamamoto, Yuji; Nawata, Atsushi; Tsuda, Eiichi; Nakaji, Shigeyuki; Ishibashi, Yasuyuki
2018-01-01
Trunk muscle weakness and imbalance are risk factors for postural instability, low back pain, and poor postoperative outcomes. The association between trunk muscle strength and aging is poorly understood, and establishing normal reference values is difficult. We aimed to establish the validity of a novel portable trunk muscle torque measurement instrument (PTMI). We then estimated reference data for healthy young adults and elucidated age-related weakness in trunk muscle strength. Twenty-four university students were enrolled to validate values for PTMI, and 816 volunteers from the general population who were recruited to the Iwaki Health Promotion Project were included to estimate reference data for trunk muscle strength. Trunk flexion and extension torque were measured with PTMI and KinCom, and interclass correlation coefficients (ICC) were estimated to evaluate the reliability of PTMI values. Furthermore, from the young adult reference, the age-related reduction in trunk muscle torque and the prevalence of sarcopenia among age-sex groups were estimated. The ICC in flexion and extension torque were 0.807 (p<0.001) and 0.789 (p<0.001), respectively. The prevalence of sarcopenia increased with age, and the prevalence due to flexion torque was double that of extension torque. Flexion torque decreased significantly after 60 years of age, and extension torque decreased after 70 years of age. In males over age 80, trunk muscle torque decreased to 49.1% in flexion and 63.5% in extension. In females over age 80, trunk muscle torque decreased to 60.7% in flexion and 68.4% in extension. The validity of PTMI was confirmed by correlation with KinCom. PTMI produced reference data for healthy young adults, and demonstrated age-related reduction in trunk muscle torque. Trunk sarcopenia progressed with aging, and the loss of flexion torque began earlier than extension torque. At age 80, trunk muscle torque had decreased 60% compared with healthy young adults. PMID:29471310
Sasaki, Eiji; Sasaki, Shizuka; Chiba, Daisuke; Yamamoto, Yuji; Nawata, Atsushi; Tsuda, Eiichi; Nakaji, Shigeyuki; Ishibashi, Yasuyuki
2018-01-01
Trunk muscle weakness and imbalance are risk factors for postural instability, low back pain, and poor postoperative outcomes. The association between trunk muscle strength and aging is poorly understood, and establishing normal reference values is difficult. We aimed to establish the validity of a novel portable trunk muscle torque measurement instrument (PTMI). We then estimated reference data for healthy young adults and elucidated age-related weakness in trunk muscle strength. Twenty-four university students were enrolled to validate values for PTMI, and 816 volunteers from the general population who were recruited to the Iwaki Health Promotion Project were included to estimate reference data for trunk muscle strength. Trunk flexion and extension torque were measured with PTMI and KinCom, and interclass correlation coefficients (ICC) were estimated to evaluate the reliability of PTMI values. Furthermore, from the young adult reference, the age-related reduction in trunk muscle torque and the prevalence of sarcopenia among age-sex groups were estimated. The ICC in flexion and extension torque were 0.807 (p<0.001) and 0.789 (p<0.001), respectively. The prevalence of sarcopenia increased with age, and the prevalence due to flexion torque was double that of extension torque. Flexion torque decreased significantly after 60 years of age, and extension torque decreased after 70 years of age. In males over age 80, trunk muscle torque decreased to 49.1% in flexion and 63.5% in extension. In females over age 80, trunk muscle torque decreased to 60.7% in flexion and 68.4% in extension. The validity of PTMI was confirmed by correlation with KinCom. PTMI produced reference data for healthy young adults, and demonstrated age-related reduction in trunk muscle torque. Trunk sarcopenia progressed with aging, and the loss of flexion torque began earlier than extension torque. At age 80, trunk muscle torque had decreased 60% compared with healthy young adults.
Degidi, Marco; Daprile, Giuseppe; Piattelli, Adriano
The aims of this study were to evaluate the ability of a stepped osteotomy to improve dental implant primary stability in low-density bone sites and to investigate possible correlations between primary stability parameters. The study was performed on fresh humid bovine bone classified as type III. The test group consisted of 30 Astra Tech EV implants inserted following the protocol provided by the manufacturer. The first control group consisted of 30 Astra Tech EV implants inserted in sites without the underpreparation of the apical portion. The second control group consisted of 30 Astra Tech TX implants inserted following the protocol provided by the manufacturer. Implant insertion was performed at the predetermined 30 rpm. The insertion torque data were recorded and exported as a curve; using a trapezoidal integration technique, the area underlying the curve was calculated: this area represents the variable torque work (VTW). Peak insertion torque (pIT) and resonance frequency analysis (RFA) were also recorded. A Mann-Whitney test showed that the mean VTW was significantly higher in the test group compared with the first control and second control groups; furthermore, statistical analysis showed that pIT also was significantly higher in the test group compared with the first and second control groups. Analyzing RFA values, only the difference between the test group and second control group showed statistical significance. Pearson correlation analysis showed a very strong positive correlation between pIT and VTW values in all groups; furthermore, it showed a positive correlation between pIT and RFA values and between VTW and RFA values only in the test group. Within the limitations of an in vitro study, the results show that stepped osteotomy can be a viable method to improve implant primary stability in low-density bone sites, and that, when a traditional osteotomy method is performed, RFA presents no correlation with pIT and VTW.
Thompson, Melanie L; Backman, David; Branemark, Rickard; Mechefske, Chris K
2011-05-01
Osseointegrated transfemoral implants have been introduced as a prosthetic solution for above knee amputees. They have shown great promise, providing an alternative for individuals who could not be accommodated by conventional, socket-based prostheses; however, the occurrence of device failures is of concern. In an effort to improve the strength and longevity of the device, a new design has been proposed. This study investigates the mechanical behavior of the new taper-based assembly in comparison to the current hex-based connection for osseointegrated transfemoral implant systems. This was done to better understand the behavior of components under loading, in order to optimize the assembly specifications and improve the useful life of the system. Digital image correlation was used to measure surface strains on two assemblies during static loading in bending. This provided a means to measure deformation over the entire sample and identify critical locations as the assembly was subjected to a series of loading conditions. It provided a means to determine the effects of tightening specifications and connection geometry on the material response and mechanical behavior of the assemblies. Both osseoinegrated assemblies exhibited improved strength and mechanical performance when tightened to a level beyond the current specified tightening torque of 12 N m. This was shown by decreased strain concentration values and improved distribution of tensile strain. Increased tightening torque provides an improved connection between components regardless of design, leading to increased torque retention, decreased peak tensile strain values, and a more gradual, primarily compressive distribution of strains throughout the assembly.
In vitro effect of chlorhexidine gel on torque and detorque values of implant abutment screw.
Asli, Hamid Neshandar; Saberi, Bardia Vadiati; Fatemi, Arezoo Sadat
2017-01-01
Use of chlorhexidine (CHX) gel to eliminate the malodor of implant cavity may decrease the friction coefficient and effective preload and result in abutment screw loosening. This study aimed to assess the effect of CHX gel on the preload, torque, and detorque values. This in vitro experimental study was conducted on three groups of five implants. Group A (G1) was the control group and no material was applied to the implant cavity. In Group B (G2), implant cavity was filled with saliva before abutment screw tightening. In Group C (G3), implant cavity was first filled with saliva and then with CHX gel. The abutments were torqued to 24 N/cm2 according to the manufacturer's instructions and were then loosened. These processes were repeated five times. The ratio of the mean percentage of detorque to torque values was measured in all groups. The collected data were analyzed using ANOVA and post hoc Tukey's test. No significant difference was noted between G1 and G2. Group G2 had significantly higher detorque value (p < 0.05). ANOVA detected a significant difference in the mean torque (p < 0.05) and detorque (p < 0.001) values among the three groups. G3 showed maximum difference between torque and detorque values; the minimum difference was noted in G2. Application of CHX gel (to decrease the malodor of the implant cavity) decreases the detorque and preload values and increases the risk of screw loosening.
Suer, Berkay Tolga; Yaman, Zekai; Buyuksarac, Bora
2016-01-01
Fractal analysis is a mathematical method used to describe the internal architecture of complex structures such as trabecular bone. Fractal analysis of panoramic radiographs of implant recipient sites could help to predict the quality of the bone prior to implant placement. This study investigated the correlations between the fractal dimension values obtained from panoramic radiographs and the insertion torque and resonance frequency values of mandibular implants. Thirty patients who received a total of 55 implants of the same brand, diameter, and length in the mandibular premolar and molar regions were included in the study. The same surgical procedures were applied to each patient, and the insertion torque and resonance frequency values were recorded for each implant at the time of placement. The radiographic fractal dimensions of the alveolar bone in the implant recipient area were calculated from preoperative panoramic radiographs using a box-counting algorithm. The insertion torque and resonance frequency values were compared with the fractal dimension values using the Spearman test. All implants were successful, and none were lost during the follow-up period. Linear correlations were observed between the fractal dimension and resonance frequency, between the fractal dimension and insertion torque, and between resonance frequency and insertion torque. These results suggest that the noninvasive measurement of the fractal dimension from panoramic radiographs might help to predict the bone quality, and thus the primary stability of dental implants, before implant surgery.
Somatotype variables related to muscle torque and power in judoists.
Lewandowska, Joanna; Buśko, Krzysztof; Pastuszak, Anna; Boguszewska, Katarzyna
2011-12-01
The purpose of this study was to examine the relationship between somatotype, muscle torque and power output in judoists. Thirteen judoists (age 18.4±3.1 years, body height 178.6±8.2 cm, body mass 82.3±15.9 kg) volunteered to participate in this study. Somatotype was determined using the Heath-Carter method. Maximal muscle torques of elbow, shoulder, knee, hip and trunk flexors as well as extensors were measured under static conditions. Power outputs were measured in 5 maximal cycle ergometer exercise bouts, 10 s each, at increasing external loads equal to 2.5, 5.0, 7.5, 10.0 and 12.5% of body weight. The Pearson's correlation coefficients were calculated between all parameters. The mean somatotype of judoists was: 3.5-5.9-1.8 (values for endomorphy, mesomorphy and ectomorphy, respectively). The values (mean±SD) of sum of muscle torque of ten muscle groups (TOTAL) was 3702.2±862.9 N x m. The power output ranged from 393.2±79.4 to 1077.2±275.4 W. The values of sum of muscle torque of right and left upper extremities (SUE), sum of muscle torque of right and left lower extremities (SLE), sum of muscle torque of the trunk (ST) and TOTAL were significantly correlated with the mesomorphic component (0.68, 0.80, 0.71 and 0.78, respectively). The ectomorphic component correlated significantly with values of SUE, SLE, ST and TOTAL (-0.69, -0.81, -0.71 and -0.79, respectively). Power output was also strongly correlated with both mesomorphy (positively) and ectomorphy (negatively). The results indicated that the values of mesomorphic and ectomorphic somatotype components influence muscle torque and power output, thus body build could be an important factor affecting results in judo.
76 FR 53312 - Airworthiness Directives; Agusta S.p.A. Model A109A and A109AII Helicopters
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-26
... disassembling the tail rotor hub and blades assembly and inspecting for damage. If the tightening torque value..., and no further action is required. If the tightening torque value is greater than 700 kgcm, the hub plug must be replaced with an airworthy part. Torque the new hub plug to the specified tightening...
Brizuela-Velasco, Aritza; Álvarez-Arenal, Ángel; Gil-Mur, Francisco Javier; Herrero-Climent, Mariano; Chávarri-Prado, David; Chento-Valiente, Yelko; Dieguez-Pereira, Markel
2015-10-01
To evaluate the micromobility of dental implants under occlusal loading in relation to stability measurements of resonance frequency analysis and insertion torque. The sample comprised of 24 implants inserted in 12 fresh cow ribs. Insertion torque and Osstell implant stability quotient (ISQ) measurements were recorded. An "ad hoc" acrylic premolar was made on a temporary abutment and screwed to each implant, and a force of 100 N was subsequently applied at an angle of 6 degrees. Implant micromotion was measured using a Questar microscope with a resolution of 2 μm and an image analysis program. Data show a statistically significant inverse correlation between the ISQ values and implant micromotion under a load of 100 N (R = 0.86, P < 0.0001). The same relationship is found between insertion torque and implant micromotion, although the relationship is linear up to 34 N·cm and becomes exponential for higher values (R = 0.78, P < 0.0001). A direct correlation is established between insertion torque and ISQ values. There is an inverse relationship between both ISQ and insertion torque values and implant micromotion under a load of 100 N.
Li, Haoyan; Liang, Yongqiang; Zheng, Qiang
2015-01-01
To evaluate correlations between marginal bone resorption and high insertion torque value (> 50 Ncm) of dental implants and to assess the significance of immediate and early/conventional loading of implants under a certain range torque value. Specific inclusion and exclusion criteria were used to retrieve eligible articles from Ovid, PubMed, and EBSCO up to December 2013. Screening of eligible studies, quality assessment, and data extraction were conducted in duplicate. The results were expressed as random/fixed-effects models using weighted mean differences for continuous outcomes with 95% confidence intervals. Initially, 154 articles were selected (11 from Ovid, 112 from PubMed, and 31 from EBSCO). After exclusion of duplicate articles and articles that did not meet the inclusion criteria, six clinical studies were selected. Assessment of P values revealed that correlations between marginal bone resorption and high insertion torque were not statistically significant and that there was no difference between immediately versus early/conventionally loaded implants under a certain range of torque. None of the meta-analyses revealed any statistically significant differences between high insertion torque and conventional insertion torque in terms of effects on marginal bone resorption.
Tokita, Daisuke; Ebihara, Arata; Nishijo, Miki; Miyara, Kana; Okiji, Takashi
2017-10-01
The purpose of the present study was to compare 2 modes of reciprocal movement (torque-sensitive and time-dependent reciprocal rotation) with continuous rotation in terms of torque and apical force generation during nickel-titanium rotary root canal instrumentation. A custom-made automated root canal instrumentation and torque/force analyzing device was used to prepare simulated canals in resin blocks and monitor the torque and apical force generated in the blocks during preparation. Experimental groups (n = 7, each) consisted of (1) torque-sensitive reciprocal rotation with torque-sensitive vertical movement (group TqR), (2) time-dependent reciprocal rotation with time-dependent vertical movement (group TmR), and (3) continuous rotation with time-dependent vertical movement (group CR). The canals were instrumented with TF Adaptive SM1 and SM2 rotary files (SybronEndo, Orange, CA), and the torque and apical force were measured during instrumentation with SM2. The mean and maximum torque and apical force values were statistically analyzed using 1-way analysis of variance and the Tukey test (α = 0.05). The recordings showed intermittent increases of upward apical force and clockwise torque, indicating the generation and release of screw-in forces. The maximum upward apical force values in group TmR were significantly smaller than those in group CR (P < .05). The maximum torque values in clockwise and counterclockwise directions in groups TqR and TmR were significantly smaller than those in group CR (P < .05). Under the present experimental conditions using TF Adaptive instruments, both torque-sensitive and time-dependent reciprocal rotation generated significantly lower maximum torque and may have advantages in reducing stress generation caused by screw-in forces when compared with continuous rotation. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Evaluation of torque maintenance of abutment and cylinder screws with Morse taper implants.
Ferreira, Mayara Barbosa; Delben, Juliana Aparecida; Barão, Valentim Adelino Ricardo; Faverani, Leonardo Perez; Dos Santos, Paulo Henrique; Assunção, Wirley Gonçalves
2012-11-01
The screw loosening of implant-supported prostheses is a common mechanical failure and is related to several factors as insertion torque and preload. The aim of this study was to evaluate the torque maintenance of retention screws of tapered abutments and cylinders of Morse taper implants submitted to retightening and detorque measurements. Two groups were obtained (n = 12): group I-tapered abutment connected to the implant with titanium retention screw and group II-cylinder with metallic base connected to tapered abutment with titanium retention screw. The detorque values were measured by an analogic torque gauge after 3 minutes of torque insertion. The detorque was measured 10 times for each retention screw of groups I and II, totalizing 120 detorque measurements in each group. Data were submitted to ANOVA and Fisher exact test (P < 0.05). Both groups presented reduced detorque value (P < 0.05) in comparison to the insertion torque in all measurement periods. There was a statistically significant difference (P < 0.05) between the detorque values of the first measurement and the other measurement periods for the abutment screw. However, there was no statistically significant difference (P > 0.05) for the detorque values of all measurement periods for the cylinder screw. In conclusion, the abutment and cylinder screws exhibited torque loss after insertion, which indicates the need for retightening during function of the implant-supported prostheses.
Influence on grip of knife handle surface characteristics and wearing protective gloves.
Claudon, Laurent
2006-11-01
Ten subjects were asked to apply maximum torques on knife handles with either their bare hand or their hand wearing a Kevlar fibre protective glove. Four knife handles (2 roughnesses, 2 hardnesses) were tested. Surface electromyograms of 6 upper limb and shoulder muscles were recorded and subject opinions on both knife handle hardness and friction in the hand were also assessed. The results revealed the significant influence of wearing gloves (p<0.0001), knife type (p<0.0005) and handle hardness (p<0.005) on the applied torque. Wearing Kevlar fibre gloves greatly increased the torque independently of the other two parameters. Under the bare hand condition, a 90 degrees ShA slightly rough handle provided the greatest torque. Subject opinion agreed with the observed effects on recorded torque values except for the hardness factor, for which a preference for the 70 degrees ShA value over the 90 degrees ShA value emerged.
Anandkumar, Sudarshan; Sudarshan, Shobhalakshmi; Nagpal, Pratima
2014-08-01
Double blind pre-test post-test control group design. To compare the isokinetic quadriceps torque, standardized stair-climbing task (SSCT) and pain during SSCT between subjects diagnosed with knee osteoarthritis pre and post kinesio tape (KT) application with and without tension. Strength of the quadriceps and torque producing capability is frequently found to be compromised in knee osteoarthritis. The efficacy of KT in improving isokinetic quadriceps torque in knee osteoarthritis is unknown, forming the basis for this study. Forty subjects were randomly allocated to either the experimental (therapeutic KT with tension) or control group (sham KT without tension) with the allocation being concealed. Pre and post test measurements of isokinetic quadriceps torque, SSCT and pain during SSCT were carried out by a blinded assessor. A large effect size with significant improvements in the peak quadriceps torque (concentric and eccentric at angular velocities of 90° per second and 120° per second), SSCT and pain were obtained in the experimental group when compared to the control group. Application of therapeutic KT is effective in improving isokinetic quadriceps torque, SSCT and reducing pain in knee osteoarthritis.
van Leeuwen, Johan L; Voesenek, Cees J; Müller, Ulrike K
2015-09-06
Small undulatory swimmers such as larval zebrafish experience both inertial and viscous forces, the relative importance of which is indicated by the Reynolds number (Re). Re is proportional to swimming speed (vswim) and body length; faster swimming reduces the relative effect of viscous forces. Compared with adults, larval fish experience relatively high (mainly viscous) drag during cyclic swimming. To enhance thrust to an equally high level, they must employ a high product of tail-beat frequency and (peak-to-peak) amplitude fAtail, resulting in a relatively high fAtail/vswim ratio (Strouhal number, St), and implying relatively high lateral momentum shedding and low propulsive efficiency. Using kinematic and inverse-dynamics analyses, we studied cyclic swimming of larval zebrafish aged 2-5 days post-fertilization (dpf). Larvae at 4-5 dpf reach higher f (95 Hz) and Atail (2.4 mm) than at 2 dpf (80 Hz, 1.8 mm), increasing swimming speed and Re, indicating increasing muscle powers. As Re increases (60 → 1400), St (2.5 → 0.72) decreases nonlinearly towards values of large swimmers (0.2-0.6), indicating increased propulsive efficiency with vswim and age. Swimming at high St is associated with high-amplitude body torques and rotations. Low propulsive efficiencies and large yawing amplitudes are unavoidable physical constraints for small undulatory swimmers. © 2015 The Author(s).
van Leeuwen, Johan L.; Voesenek, Cees J.; Müller, Ulrike K.
2015-01-01
Small undulatory swimmers such as larval zebrafish experience both inertial and viscous forces, the relative importance of which is indicated by the Reynolds number (Re). Re is proportional to swimming speed (vswim) and body length; faster swimming reduces the relative effect of viscous forces. Compared with adults, larval fish experience relatively high (mainly viscous) drag during cyclic swimming. To enhance thrust to an equally high level, they must employ a high product of tail-beat frequency and (peak-to-peak) amplitude fAtail, resulting in a relatively high fAtail/vswim ratio (Strouhal number, St), and implying relatively high lateral momentum shedding and low propulsive efficiency. Using kinematic and inverse-dynamics analyses, we studied cyclic swimming of larval zebrafish aged 2–5 days post-fertilization (dpf). Larvae at 4–5 dpf reach higher f (95 Hz) and Atail (2.4 mm) than at 2 dpf (80 Hz, 1.8 mm), increasing swimming speed and Re, indicating increasing muscle powers. As Re increases (60 → 1400), St (2.5 → 0.72) decreases nonlinearly towards values of large swimmers (0.2–0.6), indicating increased propulsive efficiency with vswim and age. Swimming at high St is associated with high-amplitude body torques and rotations. Low propulsive efficiencies and large yawing amplitudes are unavoidable physical constraints for small undulatory swimmers. PMID:26269230
Mahieu, Nele N; Witvrouw, Erik; Van de Voorde, Danny; Michilsens, Diny; Arbyn, Valérie; Van den Broecke, Wouter
2006-01-01
Several groups have undertaken studies to evaluate the physiologic effects of whole-body vibration (WBV). However, the value of WBV in a training program remains unknown. To investigate whether a WBV program results in a better strength and postural control performance than an equivalent exercise program performed without vibration. Randomized, controlled trial. Laboratory. Thirty-three Belgian competitive skiers (ages = 9-15 years). Subjects were assigned to either the WBV group or the equivalent resistance (ER) group for 6 weeks of training at 3 times per week. Isokinetic plantar and dorsiflexion peak torque, isokinetic knee flexion and extension peak torque, explosive strength (high box test), and postural control were assessed before and after the training period. Both training programs significantly improved isokinetic ankle and knee muscle strength and explosive strength. Moreover, the increases in explosive strength and in plantar-flexor strength at low speed were significantly higher in the WBV group than in the ER group after 6 weeks. However, neither WBV training nor ER training seemed to have an effect on postural control. A strength training program that includes WBV appears to have additive effects in young skiers compared with an equivalent program that does not include WBV. Therefore, our findings support the hypothesis that WBV training may be a beneficial supplementary training technique in strength programs for young athletes.
Measurement of clinicians' ability to hand torque dental implant components.
Kanawati, Ali; Richards, Mark W; Becker, Jeffery J; Monaco, Natalie E
2009-01-01
There is a varying degree of hand torque abilities using finger drivers among clinicians. Calibrating one's own abilities requires complicated instruments not readily available. This study evaluated a simple-to-use method that allows dental practitioners to have a quantifiable clinical assessment of relative torque ability using finger drivers to torque down dental implant components. A typodont that includes dental implants was mounted in a mannequin placed in a patient-reclined position. The subjects were asked to torque as tightly as they could a new healing abutment to an implant secured firmly in resin within the typodont. All participants wore moistened gloves when using a finger driver. The healing abutment was countertorqued using a certified precalibrated precision torque measurement device. The reading on the torque driver was recorded when the healing abutment disengaged. An average of torque values of dentists and dental students was calculated. Fifty subjects had an average maximum torque ability of 24 Ncm (male dentists: 28 Ncm; students: 22 Ncm; male students: 24 Ncm; female students: 19 Ncm). Maximum torque values for all participants ranged from 11 Ncm to 38 Ncm. There was no significant difference between groups. This study showed a varying degree of hand torquing abilities using a finger driver. Clinicians should regularly calibrate their ability to torque implant components to more predictably perform implant dentistry. Dental implant manufacturers should more precisely instruct clinicians as to maximum torque, as opposed to "finger tighten only".
Forearm Torque and Lifting Strength: Normative Data.
Axelsson, Peter; Fredrikson, Per; Nilsson, Anders; Andersson, Jonny K; Kärrholm, Johan
2018-02-10
To establish reference values for new methods designed to quantitatively measure forearm torque and lifting strength and to compare these values with grip strength. A total of 499 volunteers, 262 males and 237 females, aged 15 to 85 (mean, 44) years, were tested for lifting strength and forearm torque with the Kern and Baseline dynamometers. These individuals were also tested for grip strength with a Jamar dynamometer. Standardized procedures were used and information about sex, height, weight, hand dominance, and whether their work involved high or low manual strain was collected. Men had approximately 70% higher forearm torque and lifting strength compared with females. Male subjects aged 26 to 35 years and female subjects aged 36 to 45 years showed highest strength values. In patients with dominant right side, 61% to 78% had a higher or equal strength on this side in the different tests performed. In patients with dominant left side, the corresponding proportions varied between 41% and 65%. There was a high correlation between grip strength and forearm torque and lifting strength. Sex, body height, body weight, and age showed a significant correlation to the strength measurements. In a multiple regression model sex, age (entered as linear and squared) could explain 51% to 63% of the total variances of forearm torque strength and 30% to 36% of lifting strength. Reference values for lifting strength and forearm torque to be used in clinical practice were acquired. Grip strength has a high correlation to forearm torque and lifting strength. Sex, age, and height can be used to predict forearm torque and lifting strength. Prediction equations using these variables were generated. Normative data of forearm torque and lifting strength might improve the quality of assessment of wrist and forearm disorders as well as their treatments. Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
40 CFR 92.116 - Engine output measurement system calibrations.
Code of Federal Regulations, 2010 CFR
2010-07-01
... spaced torque values as indicated by the master load-cell for each in-use range used. (v) The in-use torque measurement must be within 2 percent of the torque measured by the master system for each load... the calibration equipment described in this section. (2) The engine flywheel torque feedback signals...
The relation between knee muscle strength and performance tests in orienteering athletes.
Çinar-Medeni, Özge; Colakoglu, Fatma F; Yüce, Koray; Ipekoğlu, Gökhan; Baltaci, Gul
2016-11-01
The aim of this study was to analyze the effect of knee muscle strength on performance tests in orienteers. Thirty-seven orienteers were voluntarily included in this study. Isokinetic knee flexor and extensor muscles' strength was assessed at 120°/s velocity for both "dominant leg" (DL) and "non-dominant leg" (NDL). "Single-legged hop test" (SLHT), "flamingo balance test" (FBT), "star excursion balance test" (SEBT), vertical jump-and-reach test (for anaerobic power), T-drill test and 20-meter shuttle run test (for aerobic power) were carried out. Correlation and regression analyses were performed on the data. VO2max levels showed moderate correlations with DL's "flexor peak torque" (FPT) and NDL's "extensor peak torque" (EPT) and FPT values respectively (r=0.49, r=0.38, r=0.58). FPT of NDL was a predictor of VO2max level (R2=0.33). Anaerobic power has a relationship with EPT of NDL (r=0.43) and T-drill test with EPT and FPT values of both DL and NDL respectively (r=-0.35, r=-0.63, r=-0.53, r=-0.58). EPT of NDL was a predictor for anaerobic power (R2=0.19) and FPT of DL for agility (R2=0.40). Nonparametric linear regression results showed that EPT is a predictor in DL (median slope=-0.71, P=0.01), and FPT in NDL (median slope=-0.90, P=0.006) for FBT. FPT was a predictor of SEBT scores for both legs (0.13
Interleaved neuromuscular electrical stimulation: Motor unit recruitment overlap.
Wiest, Matheus J; Bergquist, Austin J; Schimidt, Helen L; Jones, Kelvin E; Collins, David F
2017-04-01
In this study, we quantified the "overlap" between motor units recruited by single pulses of neuromuscular electrical stimulation (NMES) delivered over the tibialis anterior muscle (mNMES) and the common peroneal nerve (nNMES). We then quantified the torque produced when pulses were alternated between the mNMES and nNMES sites at 40 Hz ("interleaved" NMES; iNMES). Overlap was assessed by comparing torque produced by twitches evoked by mNMES, nNMES, and both delivered together, over a range of stimulus intensities. Trains of iNMES were delivered at the intensity that produced the lowest overlap. Overlap was lowest (5%) when twitches evoked by both mNMES and nNMES produced 10% peak twitch torque. iNMES delivered at this intensity generated 25% of maximal voluntary dorsiflexion torque (11 Nm). Low intensity iNMES leads to low overlap and produces torque that is functionally relevant to evoke dorsiflexion during walking. Muscle Nerve 55: 490-499, 2017. © 2016 Wiley Periodicals, Inc.
Influence of strength training intensity on subsequent recovery in elderly.
Orssatto, L B R; Moura, B M; Bezerra, E S; Andersen, L L; Oliveira, S N; Diefenthaeler, F
2018-06-01
Understanding the influence of strength training intensity on subsequent recovery in elderly is important to avoid reductions in physical function during the days following training. Twenty-two elderly were randomized in two groups: G70 (65.9 ± 4.8 years, n = 11) and G95 (66.9 ± 5.1, n = 11). Baseline tests included maximum voluntary isometric contraction (peak torque and rate of torque development - RTD), countermovement jump, and functional capacity (timed up and go, stairs ascent and descent). Then, both groups performed a single strength training session with intensities of 70% (G70) or 95% (G95) of five repetition maximum. The same tests were repeated immediately, 24 h, 48 h, and 72 h after the session. Peak torque was lower than baseline immediately after for both groups and at 24 h for G95. Compared with G70, G95 had lower peak torque at 24 h and 48 h. Countermovement jump, timed up and go, stairs ascent, and RTD at 0-50 ms only differed from baseline immediately after for both groups. RTD at 0-200 ms was lower than baseline immediately after and 24 h after the session for both groups. In conclusion, reduced physical function immediately after strength training can last for 1-2 days in elderly depending on the type of physical function and intensity of training. Higher intensity resulted in greater impairment. Exercise prescription in elderly should take this into account, e.g., by gradually increasing intensity during the first months of strength training. These results have relevance for elderly who have to be fit for work or other activities in the days following strength training. Copyright © 2018 Elsevier Inc. All rights reserved.
Afschrift, Maarten; De Groote, Friedl; Verschueren, Sabine; Jonkers, Ilse
2018-01-01
The response to stance perturbations changes with age. The shift from an ankle to a hip strategy with increasing perturbation magnitude occurs at lower accelerations in older than in young adults. This strategy shift has been related to age-related changes in muscle and sensory function. However, the effect of isolated changes in muscle or sensory function on the responses following stance perturbations cannot be determined experimentally since changes in muscle and sensory function occur simultaneously. Therefore, we used predictive simulations to estimate the effect of isolated changes in (rates of change in) maximal joint torques, functional base of support, and sensory noise on the response to backward platform translations. To evaluate whether these modeled changes in muscle and sensory function could explain the observed changes in strategy; simulated postural responses with a torque-driven double inverted pendulum model controlled using optimal state feedback were compared to measured postural responses in ten healthy young and ten healthy older adults. The experimentally observed peak hip angle during the response was significantly larger (5°) and the functional base of support was smaller (0.04m) in the older than in the young adults but peak joint torques and rates of joint torque were similar during the recovery. The addition of noise to the sensed states in the predictive simulations could explain the observed increase in peak hip angle in the elderly, whereas changes in muscle function could not. Hence, our results suggest that strength training alone might be insufficient to improve postural control in elderly. Copyright © 2017 Elsevier B.V. All rights reserved.
Karaarslan, A A; Acar, N
2018-02-01
Rotation instability and locking screws failure are common problems. We aimed to determine optimal torque wrench offering maximum rotational stiffness without locking screw failure. We used 10 conventional compression nails, 10 novel compression nails and 10 interlocking nails with 30 composite femurs. We examined rotation stiffness and fracture site compression value by load cell with 3, 6 and 8 Nm torque wrenches using torsion apparatus with a maximum torque moment of 5 Nm in both directions. Rotational stiffness of composite femur-nail constructs was calculated. Rotational stiffness of composite femur-compression nail constructs compressed by 6 Nm torque wrench was 3.27 ± 1.81 Nm/angle (fracture site compression: 1588 N) and 60% more than that compressed with 3 Nm torque wrench (advised previously) with 2.04 ± 0.81 Nm/angle (inter fragmentary compression: 818 N) (P = 0.000). Rotational stiffness of composite-femur-compression nail constructs compressed by 3 Nm torque wrench was 2.04 ± 0.81 Nm/angle (fracture site compression: 818 N) and 277% more than that of interlocking nail with 0.54 ± 0.08 Nm/angle (fracture site compression: 0 N) (P = 0.000). Rotational stiffness and fracture site compression value produced by 3 Nm torque wrench was not satisfactory. To obtain maximum rotational stiffness and fracture site compression value without locking screw failure, 6 Nm torque wrench in compression nails and 8 Nm torque wrench in novel compression nails should be used.
Martin, C; Bideau, B; Ropars, M; Delamarche, P; Kulpa, R
2014-08-01
The aim of this work was to compare the joint kinetics and stroke production efficiency for the shoulder, elbow, and wrist during the serve between professionals and advanced tennis players and to discuss their potential relationship with given overuse injuries. Eleven professional and seven advanced tennis players were studied with an optoelectronic motion analysis system while performing serves. Normalized peak kinetic values of the shoulder, elbow, and wrist joints were calculated using inverse dynamics. To measure serve efficiency, all normalized peak kinetic values were divided by ball velocity. t-tests were used to determine significant differences between the resultant joint kinetics and efficiency values in both groups (advanced vs professional). Shoulder inferior force, shoulder anterior force, shoulder horizontal abduction torque, and elbow medial force were significantly higher in advanced players. Professional players were more efficient than advanced players, as they maximize ball velocity with lower joint kinetics. Since advanced players are subjected to higher joint kinetics, the results suggest that they appeared more susceptible to high risk of shoulder and elbow injuries than professionals, especially during the cocking and deceleration phases of the serve. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Ioannou, Christopher; Knight, Matthew; Daniele, Luca; Flueckiger, Lee; Tan, Ezekiel S L
2016-10-17
The objective of this study is to analyse the effectiveness of the surgical torque limiter during operative use. The study also investigates the potential differences in torque between hand and drill-based screw insertion into locking plates using a standardised torque limiter. Torque for both hand and power screw insertion was measured through a load cell, registering 6.66 points per second. This was performed in a controlled environment using synthetic bone, a locking plate and locking screws to simulate plate fixation. Screws were inserted by hand and by drill with torque values measured. The surgical torque limiter (1.5 Nm) was effective as the highest recorded reading in the study was 1.409 Nm. Comparatively, there is a statistically significant difference between screw insertion methods. Torque produced for manually driven screw insertion into locking plates was 1.289 Nm (95 % CI 1.269-1.308) with drill-powered screw insertion at 0.740 Nm (95 % CI 0.723-0.757). The surgical torque limiter proved to be effective as per product specifications. Screws inserted under power produce significantly less torque when compared to manual insertion by hand. This is likely related to the mechanism of the torque limiter when being used at higher speeds for which it was designed. We conclude that screws may be inserted using power to the plate with the addition of a torque limiter. It is recommended that all screws inserted by drill be hand tightened to achieve adequate torque values.
Väätäinen, U; Airaksinen, O; Jaroma, H; Kiviranta, I
1995-01-01
The alterations in thigh muscle properties of chondromalacia patellae patients during isometric and dynamic endurance tests were studied using a variokinetic knee testing system linked to surface EMG. A total of 41 patients (chondromalacia group) with arthroscopically certified chondromalacia of the patella were studied. The control group consisted of 31 healthy adult volunteers with no history of knee pain or trauma. Peak torque values were 21% (p < 0.01) and force output values 25% (p < 0.05) lower on the symptomatic side of the chondromalacia group than in the control group. The decrease in the ratio between integrated EMG (IEMG) and measured force were found in all parts of the quadriceps femoris muscle in patients with chondromalacia of the patella in isometric extension. No change in the normalized IEMG levels of the thigh muscles were found between chondromalacia patients and controls in dynamic endurance test. The severity of the chondromalacia of the patella did not affect the level of electromyographic activation in thigh muscles. The ratio of normalized EMG levels of vastus medialis and vastus lateralis did not differ between the groups. The present study showed that chondromalacia patellae patients have reduced force and electromyographic activation levels of quadriceps femoris muscle. Especially, the explosive strength of the quadriceps femoris muscle is reduced.
Zeno, Helios A; Buitrago, Renan L; Sternberger, Sidney S; Patt, Marisa E; Tovar, Nick; Coelho, Paulo; Kurtz, Kenneth S; Tuminelli, Frank J
2016-04-01
To compare the removal of torque values of machined implant abutment connections (internal and external) with and without soft tissue entrapment using an in vitro model. Thirty external- and 30 internal-connection implants were embedded in urethane dimethacrylate. Porcine tissue was prepared and measured to thicknesses of 0.5 and 1.0 mm. Six groups (n = 10) were studied: External- and internal-connection implants with no tissue (control), 0.5, and 1.0 mm of tissue were entrapped at the implant/abutment interface. Abutments were inserted to 20 Ncm for all six groups. Insertion torque values were recorded using a digital torque gauge. All groups were then immersed in 1 M NaOH for 48 hours to dissolve tissue. Subsequent reverse torque measurements were recorded. Mean and standard deviation were determined for each group, and one-way ANOVA and Bonferroni test were used for statistical analysis. All 60 specimens achieved a 20-Ncm insertion torque, despite tissue entrapment. Reverse torque measurements for external connection displayed a statistically significant difference (p < 0.05) between all groups with mean reverse torque values for the control (13.71 ± 1.4 Ncm), 0.5 mm (7.83 ± 2.4 Ncm), and 1.0 mm tissue entrapment (2.29 ± 1.4 Ncm) groups. Some statistically significant differences (p < 0.05) were found between internal-connection groups. In all specimens, tissue did not completely dissolve after 48 hours. External-connection implants were significantly affected by tissue entrapment; the thicker the tissue, the lower the reverse torque values noted. Internal-connection implants were less affected by tissue entrapment. © 2015 by the American College of Prosthodontists.
A comparison of preload values in gold and titanium dental implant retaining screws.
Doolabh, R; Dullabh, H D; Sykes, L M
2014-08-01
This in vitro investigation compared the effect of using either gold or titanium retaining screws on preload in the dental implant- abutment complex. Inadequate preload can result in screw loosening, whilst fracture may occur if preload is excessive. These are the most commonly reported complications in implant-retained prostheses, and result in unscheduled, costly and time-consuming visits for the patient and the clinician. This study investigated changes in preload generation after repeated torque applications to gold and titanium screws. The test set-up consisted of an implant body, a cylindrical transmucosa abutment, and the test samples of gold and of titanium retaining screws. The implant bodies were anchored using a load cell, and the transmucosal abutments were attached using either gold or titanium retaining screws. A torque gauge was used to apply torque of 20Ncm, 32Ncm, and 40Ncm to the retaining screws. The preloads generated in each screw type were compared at each torque setting, and after repeated tightening episodes. In addition, the effect of applying torque beyond the manufacturers' recommendations was also examined. Gold retaining screws were found to achieve consistently higher preload values than titanium retaining screws. Preload values were not significantly different from the first to the tenth torque cycle. Titanium screws showed more consistent preload values, albeit lower than those of the gold screws. However due to possible galling of the internal thread of the implant body by titanium screws, gold screws remain the retaining screw of choice. Based on the findings of this study, gold retaining screws generate better preload than titanium. Torque beyond the manufacturers' recommendations resulted in a more stable implant complex. However, further investigations, with torque applications repeated until screw breakage, are needed to advise on ideal maintenance protocols.
The timing of control signals underlying fast point-to-point arm movements.
Ghafouri, M; Feldman, A G
2001-04-01
It is known that proprioceptive feedback induces muscle activation when the facilitation of appropriate motoneurons exceeds their threshold. In the suprathreshold range, the muscle-reflex system produces torques depending on the position and velocity of the joint segment(s) that the muscle spans. The static component of the torque-position relationship is referred to as the invariant characteristic (IC). According to the equilibrium-point (EP) hypothesis, control systems produce movements by changing the activation thresholds and thus shifting the IC of the appropriate muscles in joint space. This control process upsets the balance between muscle and external torques at the initial limb configuration and, to regain the balance, the limb is forced to establish a new configuration or, if the movement is prevented, a new level of static torques. Taken together, the joint angles and the muscle torques generated at an equilibrium configuration define a single variable called the EP. Thus by shifting the IC, control systems reset the EP. Muscle activation and movement emerge following the EP resetting because of the natural physical tendency of the system to reach equilibrium. Empirical and simulation studies support the notion that the control IC shifts and the resulting EP shifts underlying fast point-to-point arm movements are gradual rather than step-like. However, controversies exist about the duration of these shifts. Some studies suggest that the IC shifts cease with the movement offset. Other studies propose that the IC shifts end early in comparison to the movement duration (approximately, at peak velocity). The purpose of this study was to evaluate the duration of the IC shifts underlying fast point-to-point arm movements. Subjects made fast (hand peak velocity about 1.3 m/s) planar arm movements toward different targets while grasping a handle. Hand forces applied to the handle and shoulder/elbow torques were, respectively, measured from a force sensor placed on the handle, or computed with equations of motion. In some trials, an electromagnetic brake prevented movements. In such movements, the hand force and joint torques reached a steady state after a time that was much smaller than the movement duration in unobstructed movements and was approximately equal to the time to peak velocity (mean difference < 80 ms). In an additional experiment, subjects were instructed to rapidly initiate corrections of the pushing force in response to movement arrest. They were able to initiate such corrections only when the joint torques and the pushing force had practically reached a steady state. The latency of correction onset was, however, smaller than the duration of unobstructed movements. We concluded that during the time at which the steady state torques were reached, the control pattern of IC shifts remained the same despite the movement block. Thereby the duration of these shifts did not exceed the time of reaching the steady state torques. Our findings are consistent with the hypothesis that, in unobstructed movements, the IC shifts and resulting shifts in the EP end approximately at peak velocity. In other words, during the latter part of the movement, the control signals responsible for the equilibrium shift remained constant, and the movement was driven by the arm inertial, viscous and elastic forces produced by the muscle-reflex system. Fast movements may thus be completed without continuous control guidance. As a consequence, central corrections and sequential commands may be issued rapidly, without waiting for the end of kinematic responses to each command, which may be important for many motor behaviours including typing, piano playing and speech. Our study also illustrates that the timing of the control signals may be substantially different from that of the resulting motor output and that the same control pattern may produce different motor outputs depending on external conditions.
Somatotype Variables Related to Muscle Torque and Power in Judoists
Lewandowska, Joanna; Buśko, Krzysztof; Pastuszak, Anna; Boguszewska, Katarzyna
2011-01-01
The purpose of this study was to examine the relationship between somatotype, muscle torque and power output in judoists. Thirteen judoists (age 18.4±3.1 years, body height 178.6±8.2 cm, body mass 82.3±15.9 kg) volunteered to participate in this study. Somatotype was determined using the Heath-Carter method. Maximal muscle torques of elbow, shoulder, knee, hip and trunk flexors as well as extensors were measured under static conditions. Power outputs were measured in 5 maximal cycle ergometer exercise bouts, 10 s each, at increasing external loads equal to 2.5, 5.0, 7.5, 10.0 and 12.5% of body weight. The Pearson’s correlation coefficients were calculated between all parameters. The mean somatotype of judoists was: 3.5-5.9-1.8 (values for endomorphy, mesomorphy and ectomorphy, respectively). The values (mean±SD) of sum of muscle torque of ten muscle groups (TOTAL) was 3702.2±862.9 N x m. The power output ranged from 393.2±79.4 to 1077.2±275.4 W. The values of sum of muscle torque of right and left upper extremities (SUE), sum of muscle torque of right and left lower extremities (SLE), sum of muscle torque of the trunk (ST) and TOTAL were significantly correlated with the mesomorphic component (0.68, 0.80, 0.71 and 0.78, respectively). The ectomorphic component correlated significantly with values of SUE, SLE, ST and TOTAL (−0.69, −0.81, −0.71 and −0.79, respectively). Power output was also strongly correlated with both mesomorphy (positively) and ectomorphy (negatively). The results indicated that the values of mesomorphic and ectomorphic somatotype components influence muscle torque and power output, thus body build could be an important factor affecting results in judo. PMID:23487284
Davis, Hope C; Troy Blackburn, J; Ryan, Eric D; Luc-Harkey, Brittney A; Harkey, Matthew S; Padua, Darin A; Pietrosimone, Brian
2017-07-01
The purpose of this study was to determine associations between self-reported function (International Knee Documentation Committee Index), isometric quadriceps strength and rate of torque development in individuals with a unilateral anterior cruciate ligament reconstruction. Forty-one individuals [31% male, BMI mean 25 (SD 4) kg/m 2 , months post anterior cruciate ligament reconstruction mean 49 (SD 40)] completed the self-reported function and isometric quadriceps function testing. Rate of torque development was assessed at 0-100ms (early), 100-200ms (late) ms, and peak following the onset of contraction. Associations were examined between rate of torque development, strength, and self-reported function. Linear regression was used to determine the unique amount of variance explained by the combination of rate of torque development and strength. Higher rate of torque development 100-200ms is weakly associated with higher self-reported function in individuals with a unilateral anterior cruciate ligament reconstruction (r=0.274, p=0.091); however, rate of torque development 100-200ms does not predict a significant amount of variance in self-reported function after accounting for strength (ΔR 2 =0.003, P=0.721). Quadriceps strength has a greater influence on self-reported function compared to rate of torque development in individuals with an anterior cruciate ligament reconstruction with time from surgery. Copyright © 2017 Elsevier Ltd. All rights reserved.
The effect of repeated torque in small diameter implants with machined and premachined abutments.
Saboury, Abolfazl; Neshandar Asli, Hamid; Vaziri, Shahram
2012-05-01
Detorquing value is an important factor in the amount of preload stresses during abutment screw fastening. This study evaluated the percentage of detorque values in two-piece machined titanium and premachined cast abutments in small diameter implants. Three groups of five samples were evaluated. Group 1 (G1), machined titanium abutments, group 2 (G2), premachined cast straight abutments that cast with gold-palladium, and group 3 (G3), premachined angled cast abutments that cast with the same alloy, were angled before casting. Each abutment was torque to 24 Ncm according to the manufacturer's instructions and detorqued five times. The means of detorquing and torquing values in all groups were recorded. The mean of detorque in each group as a percentage of the toque value was calculated. The data for all groups were compared and calculated using analysis of variance (ANOVA) and t-test. Mean detorque values in G1, G2, and G3 were 88.1 ± 1.69, 93.1 ± 2.68, and 80.9 ± 4.95%, respectively. The ANOVA showed significant differences in mean of applied detorque (p < .001) and torque (p = .06) tightening among different groups. G2 had significantly greater detorque values (p < .05). No significant differences were found between G1 and G2. Surprisingly, abutment screw fracture occurred in three samples of G3. G3 showed significant percentage torque reduction (p < .05) and exhibited abutment screw fracture during evaluation. G2 presented the lowest torque reduction. Screw fracture occurred only in G3. © 2012 Wiley Periodicals, Inc.
Comparison of analysis and experiment for dynamics of low-contact-ratio spur gears
NASA Technical Reports Server (NTRS)
Oswald, Fred B.; Rebbechi, Brian; Zakrajsek, James J.; Townsend, Dennis P.; Lin, Hsiang Hsi
1991-01-01
Low-contact-ratio spur gears were tested in NASA gear-noise-rig to study gear dynamics including dynamic load, tooth bending stress, vibration, and noise. The experimental results were compared with a NASA gear dynamics code to validate the code as a design tool for predicting transmission vibration and noise. Analytical predictions and experimental data for gear-tooth dynamic loads and tooth-root bending stress were compared at 28 operating conditions. Strain gage data were used to compute the normal load between meshing teeth and the bending stress at the tooth root for direct comparison with the analysis. The computed and measured waveforms for dynamic load and stress were compared for several test conditions. These are very similar in shape, which means the analysis successfully simulates the physical behavior of the test gears. The predicted peak value of the dynamic load agrees with the measurement results within an average error of 4.9 percent except at low-torque, high-speed conditions. Predictions of peak dynamic root stress are generally within 10 to 15 percent of the measured values.
Sharifi, Maryam; Ghassemi, Amirreza; Bayani, Shahin
2015-01-01
Success of orthodontic miniscrews in providing stable anchorage is dependent on their stability. The purpose of this study was to assess the effect of insertion method and postinsertion time interval on the removal torque of miniscrews as an indicator of their stability. Seventy-two miniscrews (Jeil Medical) were inserted into the femoral bones of three male German Shepherd dogs and assigned to nine groups of eight miniscrews. Three insertion methods, including hand-driven, motor-driven with 5.0-Ncm insertion torque, and motor-driven with 20.0-Ncm insertion torque, were tested. Three time intervals of 0, 2, and 6 weeks between miniscrew insertion and removal were tested as well. Removal torque values were measured in newton centimeters by a removal torque tester (IMADA). Data were analyzed by one-way analysis of variance (ANOVA) followed by the Bonferroni post hoc test at a .05 level of significance. A miniscrew survival rate of 93% was observed in this study. The highest mean value of removal torque among the three postinsertion intervals (2.4 ± 0.59 Ncm) was obtained immediately after miniscrew insertion with a statistically significant difference from the other two time intervals (P < .001). Insertion were observed in this regard (P = .46). The stability of miniscrews was not affected by the insertion method. However, of the postinsertion time intervals, the highest removal torque values were obtained immediately after insertion.
Core stability training on lower limb balance strength.
Dello Iacono, Antonio; Padulo, Johnny; Ayalon, Moshe
2016-01-01
This study aimed to assess the effects of core stability training on lower limbs' muscular asymmetries and imbalances in team sport. Twenty footballers were divided into two groups, either core stability or control group. Before each daily practice, core stability group (n = 10) performed a core stability training programme, while control group (n = 10) did a standard warm-up. The effects of the core stability training programme were assessed by performing isokinetic tests and single-leg countermovement jumps. Significant improvement was found for knee extensors peak torque at 3.14 rad · s(-1) (14%; P < 0.05), knee flexors peak torque at 1.05 and 3.14 rad · s(-1) (19% and 22% with P < 0.01 and P < 0.01, respectively) and peak torque flexors/extensors ratios at 1.05 and 3.14 rad · s(-1) (7.7% and 8.5% with P < 0.05 and P < 0.05, respectively) only in the core stability group. The jump tests showed a significant reduction in the strength asymmetries in core stability group (-71.4%; P = 0.02) while a concurrent increase was seen in the control group (33.3%; P < 0.05). This study provides practical evidence in combining core exercises for optimal lower limbs strength balance development in young soccer players.
An Autologous Muscle Tissue Expansion Approach for the Treatment of Volumetric Muscle Loss
2015-07-01
potential therapy for some VML indications, autologous minced muscle grafts (1mm3 pieces of muscle ) are effective in promoting remarkable de novo fiber ...may be misaligned.9–12 More recently, minced muscle grafts were effective in promoting de novomus- cle fiber regeneration and functional recovery in...to enable torque stabilization. The contribution of the tenotomized EDL muscle was negligible in this testing system.13 Peak TA muscle isometric torque
2013-01-01
Background Vibration is known to alter proprioceptive afferents and create a tonic vibration reflex. The control of force and its variability are often considered determinants of motor performance and neuromuscular control. However, the effect of vibration on paraspinal muscle control and force production remains to be determined. Methods Twenty-one healthy adults were asked to perform isometric trunk flexion and extension torque at 60% of their maximal voluntary isometric contraction, under three different vibration conditions: no vibration, vibration frequencies of 30 Hz and 80 Hz. Eighteen isometric contractions were performed under each condition without any feedback. Mechanical vibrations were applied bilaterally over the lumbar erector spinae muscles while participants were in neutral standing position. Time to peak torque (TPT), variable error (VE) as well as constant error (CE) and absolute error (AE) in peak torque were calculated and compared between conditions. Results The main finding suggests that erector spinae muscle vibration significantly decreases the accuracy in a trunk extension isometric force reproduction task. There was no difference between both vibration frequencies with regard to force production parameters. Antagonist muscles do not seem to be directly affected by vibration stimulation when performing a trunk isometric task. Conclusions The results suggest that acute erector spinae muscle vibration interferes with torque generation sequence of the trunk by distorting proprioceptive information in healthy participants. PMID:23919578
Bento, Paulo Cesar Barauce; Rodacki, André Luiz Felix
2015-11-01
The purpose of the present study was to determine the effects of a water-based exercise program on muscle function compared with regular high-intensity resistance training. Older women (n = 87) were recruited from the local community. The inclusion criteria were, to be aged 60 years or older, able to walk and able to carry out daily living activities independently. Participants were randomly assigned to one of the following groups: water-based exercises (WBG), resistance training (RTG) or control (CG). The experimental groups carried out 12 weeks of an excise program performed on water or on land. The dynamic strength, the isometric peak, and rate of torque development for the lower limbs were assessed before and after interventions. The water-based program provided a similar improvement in dynamic strength in comparison with resistance training. The isometric peak torque increased around the hip and ankle joints in the water-based group, and around the knee joint in the resistance-training group (P < 0.05). The rate of torque development increased only in the water-based group around the hip extensors muscles (P < 0.05). Water-based programs constitute an attractive alternative to promote relevant strength gains using moderate loads and fast speed movements, which were also effective to improve the capacity to generate fast torques. © 2014 Japan Geriatrics Society.
Functional and morphological adaptations to aging in knee extensor muscles of physically active men.
Baroni, Bruno Manfredini; Geremia, Jeam Marcel; Rodrigues, Rodrigo; Borges, Marcelo Krás; Jinha, Azim; Herzog, Walter; Vaz, Marco Aurélio
2013-10-01
It is not known if a physically active lifestyle, without systematic training, is sufficient to combat age-related muscle and strength loss. Therefore, the purpose of this study was to evaluate if the maintenance of a physically active lifestyle prevents muscle impairments due to aging. To address this issue, we evaluated 33 healthy men with similar physical activity levels (IPAQ = 2) across a large range of ages. Functional (torque-angle and torque-velocity relations) and morphological (vastus lateralis muscle architecture) properties of the knee extensor muscles were assessed and compared between three age groups: young adults (30 ± 6 y), middle-aged subjects (50 ± 7 y) and elderly subjects (69 ± 5 y). Isometric peak torques were significantly lower (30% to 36%) in elderly group subjects compared with the young adults. Concentric peak torques were significantly lower in the middle aged (18% to 32%) and elderly group (40% to 53%) compared with the young adults. Vastus lateralis thickness and fascicles lengths were significantly smaller in the elderly group subjects (15.8 ± 3.9 mm; 99.1 ± 25.8 mm) compared with the young adults (19.8 ± 3.6 mm; 152.1 ± 42.0 mm). These findings suggest that a physically active lifestyle, without systematic training, is not sufficient to avoid loss of strength and muscle mass with aging.
Comparison of isokinetic muscle strength and muscle power by types of warm-up.
Sim, Young-Je; Byun, Yong-Hyun; Yoo, Jaehyun
2015-05-01
[Purpose] The purpose of this study was to clarify the influence of static stretching at warm-up on the isokinetic muscle torque (at 60°/sec) and muscle power (at 180°/sec) of the flexor muscle and extensor muscle of the knee joint. [Subjects and Methods] The subjects of this study were 10 healthy students with no medically specific findings. The warm-up group and warm-up with stretching group performed their respective warm-up prior to the isokinetic muscle torque evaluation of the knee joint. One-way ANOVA was performed by randomized block design for each variable. [Results] The results were as follows: First, the flexor peak torque and extensor peak torque of the knee joint tended to decrease at 60°/sec in the warm-up with stretching group compared with the control group and warm-up group, but without statistical significance. Second, extensor power at 180°/sec was also not statistically significant. However, it was found that flexor power increased significantly in the warm-up with stretching group at 180°/sec compared with the control group and warm-up group in which stretching was not performed. [Conclusion] Therefore, it is considered that in healthy adults, warm-up including two sets of stretching for 20 seconds per muscle group does not decrease muscle strength and muscle power.
NASA Technical Reports Server (NTRS)
Dudley, Gary A.; Duvoisin, Marc R.; Convertino, Victor A.; Buchanan, Paul
1989-01-01
The purpose of this study was to examine the effect of 30 d of 6 deg headdown bedrest (BR) on the in vivo strength of skeletal muscle. Peak angle specific (0.78 rad below horizontal) torque of the knee extensor (KE) and flexor (KF) muscle groups of both limbs was assessed during unilateral efforts at four speeds (0.52, 1.74, 2.97 and 4.19 rad/s) during concentric and at three speeds (0.52, 1.74 and 2.97 rad/s) during eccentric actions. The average decrease (P less than 0.05) of peak angle specific torque directly post-BR for the KE across speeds of concentric and eccentric actions was about 19% (n = 7). Recovery for 30 d following BR markedly improved strength to about 92% (P greater than 0.05) of 'normal'. Strength of the KF was not altered (P greater than 0.05) by BR (about a 6% decrease independent of speed and type of muscle action). Changes of strength were not affected by the type or speed of muscle action. The results indicate that strength of ex-tensor more than of flexor muscle groups of the lower limb is decreased by 30 d of bedrest and that this response does not alter the nature of the in vivo torque-velocity relation.
Dulal, Nabeen; Shanks, Robert; Gengenbach, Thomas; Gill, Harsharn; Chalmers, David; Adhikari, Benu; Pardo Martinez, Isaac
2017-11-01
The amount and distribution of slip agents, erucamide, and behenamide, on the surface of high-density polyethene, is determined by integral characteristics of slip agent structure and polymer morphology. A suite of surface analysis techniques was applied to correlate physicochemical properties with slip-additive migration behaviour and their surface morphology. The migration, surface morphology and physicochemical properties of the slip additives, crystallinity and orientation of polyethene spherulites and interaction between slip additives and high-density polyethene influence the surface characteristics. The high-density polyethene closures were produced with erucamide and behenamide separately and stored until they produced required torque. Surface composition was determined employing spectroscopy and gas chromatography. The distribution of additives was observed under optical, scanning electron and atomic force microscopes. The surface energy, crystallinity and application torque were measured using contact angle, differential scanning calorimeter and a torque force tester respectively. Each slip additive produced a characteristic amide peak at 1645cm -1 in infrared spectroscopy and peaks of oxygen and nitrogen in X-ray photoelectron spectroscopy, suggesting their presence on the surface. The erucamide produced placoid scale-like structures and behenamide formed denticulate structures. The surface erucamide and behenamide responsible for reducing the torque was found to be 15.7µg/cm 2 and 1.7µg/cm 2 . Copyright © 2017 Elsevier Inc. All rights reserved.
40 CFR 1039.515 - What are the test procedures related to not-to-exceed standards?
Code of Federal Regulations, 2010 CFR
2010-07-01
...; however, use the power value corresponding to the engine operation at 30% of maximum torque at the B speed... 50% torque/power points) and below the line formed by connecting the two points in paragraphs (b)(2)(ii) and (iii) of this section (the 50% and 70% torque/power points). The 30%, 50%, and 70% torque...
Fracture of Reduced-Diameter Zirconia Dental Implants Following Repeated Insertion.
Karl, Matthias; Scherg, Stefan; Grobecker-Karl, Tanja
Achievement of high insertion torque values indicating good primary stability is a goal during dental implant placement. The objective of this study was to evaluate whether or not two-piece implants made from zirconia ceramic may be damaged as a result of torque application. A total of 10 two-piece zirconia implants were repeatedly inserted into polyurethane foam material with increasing density and decreasing osteotomy size. The insertion torque applied was measured, and implants were checked for fractures by applying the fluorescent penetrant method. Weibull probability of failure was calculated based on the recorded insertion torque values. Catastrophic failures could be seen in five of the implants from two different batches at insertion torques ranging from 46.0 to 70.5 Ncm, while the remaining implants (all belonging to one batch) survived. Weibull probability of failure seems to be low at the manufacturer-recommended maximum insertion torque of 35 Ncm. Chipping fractures at the thread tips as well as tool marks were the only otherwise observed irregularities. While high insertion torques may be desirable for immediate loading protocols, zirconia implants may fracture when manufacturer-recommended insertion torques are exceeded. Evaluating bone quality prior to implant insertion may be useful.
Estimation of muscle torque in various combat sports.
Pędzich, Wioletta; Mastalerz, Andrzej; Sadowski, Jerzy
2012-01-01
The purpose of the research was to compare muscle torque of elite combat groups. Twelve taekwondo WTF athletes, twelve taekwondo ITF athletes and nine boxers participated in the study. Measurements of muscle torques were done under static conditions on a special stand which belonged to the Department of Biomechanics. The sum of muscle torque of lower right and left extremities of relative values was significantly higher for taekwondo WTF athletes than for boxers (16%, p < 0.001 for right and 10%, p < 0.05 for left extremities) and taekwondo ITF (10%, p < 0.05 for right and 8% for left extremities). Taekwondo ITF athletes attained significantly higher absolute muscle torque values than boxers for elbow flexors (20%, p < 0.05 for right and 11% for left extremities) and extensors (14% for right and 18%, p < 0.05 for left extremities) and shoulder flexors (10% for right and 12%, p < 0.05 for left extremities) and extensors (11% for right and 1% for left extremities). Taekwondo WTF and taekwondo ITF athletes obtained significantly different relative values of muscle torque of the hip flexors (16%, p < 0.05) and extensors (11%, p < 0.05) of the right extremities.
Palmer, Ty B; Thiele, Ryan M; Thompson, Brennan J
2017-02-01
Palmer, TB, Thiele, RM, and Thompson, BJ. Age-related differences in maximal and rapid torque characteristics of the hip extensors and dynamic postural balance in healthy, young and old females. J Strength Cond Res 31(2): 480-488, 2017-The purpose of this study was to examine age-related differences in maximal and rapid torque characteristics of the hip extensor muscles and dynamic postural balance in healthy, young and older females. Eleven younger (age, 26 ± 8 years) and 11 older (age, 67 ± 8 years) females performed 2 isometric maximal voluntary contractions (MVCs) of the hip extensor muscles. Absolute and relative peak torque (PT) and rate of torque development (RTD) at early (0-50 ms) and late (0-200 ms) phases of muscle contraction were examined during each MVC. Dynamic postural balance was assessed using a commercially designed balance testing device, which provides a measurement of dynamic stability based on the overall stability index (OSI). Results indicated that absolute PT and early (RTD50) and late (RTD200) RTD variables were lower (p = 0.009-0.050), and postural OSI was higher (p = 0.011) in the old compared with the younger females; however, no differences were observed for relative PT or RTD variables (p = 0.113-0.895). A significant relationship was also observed in the older (r = -0.601; p = 0.050) but not the younger (r = -0.132; p = 0.698) females between RTD50 and OSI. The lower absolute PT and RTD and higher OSI values for the old females may contribute to the increased functional limitations often observed in older adults. The significant relationship observed in the older females between OSI and RTD50 perhaps suggests that these age-related declines in explosive strength may be an important characteristic relevant to dynamic balance scores, especially in older populations.
Why do Cross-Flow Turbines Stall?
NASA Astrophysics Data System (ADS)
Cavagnaro, Robert; Strom, Benjamin; Polagye, Brian
2015-11-01
Hydrokinetic turbines are prone to instability and stall near their peak operating points under torque control. Understanding the physics of turbine stall may help to mitigate this undesirable occurrence and improve the robustness of torque controllers. A laboratory-scale two-bladed cross-flow turbine operating at a chord-based Reynolds number ~ 3 ×104 is shown to stall at a critical tip-speed ratio. Experiments are conducting bringing the turbine to this critical speed in a recirculating current flume by increasing resistive torque and allowing the rotor to rapidly decelerate while monitoring inflow velocity, torque, and drag. The turbine stalls probabilistically with a distribution generated from hundreds of such events. A machine learning algorithm identifies stall events and indicates the effectiveness of available measurements or combinations of measurements as predictors. Bubble flow visualization and PIV are utilized to observe fluid conditions during stall events including the formation, separation, and advection of leading-edge vortices involved in the stall process.
Kim, Moon-Hwan; Oh, Jae-Seop
2015-01-01
[Purpose] The purpose of this study was to examine the effects of humeral head compression taping (HHCT) on the strength of the shoulder external rotator muscle in patients with rotator cuff tendinitis. [Subjects and Methods] Twenty patients with rotator cuff tendinitis were recruited. The shoulder external rotator strength was measured using a Biodex isokinetic dynamometer system. A paired t-test was performed to evaluate within-group differences in the strength of the shoulder external rotator muscle. [Results] Significantly higher shoulder external rotator peak torque and peak torque per body weight were found in the HHCT condition than in the no-taping condition. [Conclusion] HHCT may effectively increase the shoulder external rotator muscle strength in patients with rotator cuff tendinitis.
Predicting rheological behavior and baking quality of wheat flour using a GlutoPeak test.
Rakita, Slađana; Dokić, Ljubica; Dapčević Hadnađev, Tamara; Hadnađev, Miroslav; Torbica, Aleksandra
2018-06-01
The purpose of this research was to gain an insight into the ability of the GlutoPeak instrument to predict flour functionality for bread making, as well as to determine which of the GlutoPeak parameters show the best potential in predicting dough rheological behavior and baking performance. Obtained results showed that GlutoPeak parameters correlated better with the indices of extensional rheological tests which consider constant dough hydration than with those which were performed at constant dough consistency. The GlutoPeak test showed that it is suitable for discriminating wheat varieties of good quality from those of poor quality, while the most discriminating index was maximum torque (MT). Moreover, MT value of 50 BU and aggregation energy value of 1,300 GPU were set as limits of wheat flour quality. The backward stepwise regression analysis revealed that a high-level prediction of indices which are highly affected by protein content (gluten content, flour water absorption, and dough tenacity) was achieved by using the GlutoPeak indices. Concerning bread quality, a moderate prediction of specific loaf volume and an intense level prediction of breadcrumb textural properties were accomplished by using the GlutoPeak parameters. The presented results indicated that the application of this quick test in wheat transformation chain for the assessment of baking quality would be useful. Baking test is considered as the most reliable method for assessing wheat-baking quality. However, baking test requires trained stuff, time, and large sample amount. These disadvantages have led to a growing demand to develop new rapid tests which would enable prediction of baked product quality with a limited flour size. Therefore, we tested the possibility of using a GlutoPeak tester to predict loaf volume and breadcrumb textural properties. Discrimination of wheat varieties according to quality with a restricted flour amount was also examined. Furthermore, we proposed the limit values of GlutoPeak parameters which would be highly beneficial for millers and bakers when determine suitability of flour for end-use. © 2017 Wiley Periodicals, Inc.
Butkevica, Alena; Nathanson, Dan; Pober, Richard; Strating, Herman
2018-02-01
Repeated tightening and loosening of the abutment screw may alter its mechanical and physical properties affecting the optimal torque and ultimate reliability of an implant/abutment connection. The purpose of this study was to evaluate the effect of repeated tightening and loosening of implant/abutment screws on the loosening torque of implant/abutment connections of commercially available implant systems. Seven different implant/abutment connections and their modifications were tested. The screws of each system were tightened according to the manufacturer's specifications. After 20 minutes the screws were loosened. This procedure was repeated ten times, and the differences between the 1st and 10th cycle were expressed as a percentage change RTq(%) and correlated with initial torque, the number of threads, the length of shank, and thread surface area employing Spearman's analysis. All systems showed significant differences in residual torque (RTq) value (p < 0.05) between the 1st and 10th cycle except groups 6 and 11 (p > 0.05). All connections but group 3 (p = 1.000) showed a significant change from the initial torque (ITq) to the RTq values. The first successive RTq values increased in two connection groups 1 and 2. The remaining connections showed reduced RTq values ranging from -1.2 % (group 5) to -23.5% (group 6). The RTq values declined gradually with every repeated tightening in groups 1, 2, 3, 8, 9, 11, 12. In group 2, after the tenth tightening the RTq was still above the ITq value. Only length of shank demonstrated a correlation with the RTq(%) change over the successive tightening loosening cycles (p < 0.05). Repeated tightening and loosening of implant/abutment screws caused varying torque level changes among the different systems. These observations can probably be attributed to connection design. Limiting the number of tightening/loosening cycles in clinical and laboratory procedures is advisable for most of the implant systems tested. © 2016 by the American College of Prosthodontists.
Ismail, M M; Gamaleldein, M H; Hassa, K A
2013-10-01
Patellofemoral pain syndrome (PFPS) is a common musculoskeletal pain condition, especially in females. Decreased hip muscle strength has been implicated as a contributing factor. Isolated open kinetic chain hip abductors and lateral rotators exercises were added by many authors to the rehabilitation program. However, Closed Kinetic Chain (CKC) exercises focusing on hip and knee muscles were not investigated if they can produce similar effect of hip strengthening and decreasing pain without the need of isolated exercises for hip musculature. The aim of the present study was to determine the effect of a CKC exercises program with or without additional hip strengthening exercises on pain and hip abductors and lateral rotators peak torque. Prospective randomized clinical trial. Patients with patellofemoral pain syndrome referred to the outpatient physical therapy clinic of the faculty of physical therapy, cairo university. Thirty two patients who had patellofemoral pain syndrome with age ranged from eighteen to thirty years. Patients were randomly assigned into two groups: CKC group and CKC with hip muscles strengthening exercises as a control (CO) group. Treatment was given 3 times/week, for 6 weeks. Patients were evaluated pre- and post-treatment for their pain severity using VAS, function of knee joint using Kujala questionnaire, hip abductors and external rotators concentric/eccentric peak torque. There were significant improvements in pain, function and hip muscles peak torque in both groups (P<0.05). However, there was no statistically significant difference between groups in hip muscles torque (P<0.05) but pain and function improvements were significantly greater in the CO group (P<0.05). Six weeks CKC program focusing on knee and hip strengthening has similar effect in improving hip muscles torque in patients with PFPS as a CKC exercises with additional hip strengthening exercises. However, adding isolated hip strengthening exercises has the advantage of more pain relief. CKC exercises with additional hip strengthening could be more beneficial in decreasing pain in PFPS than CKC exercises alone.
Forte, Roberta; Pesce, Caterina; Leite, Joao Costa; De Vito, Giuseppe; Gibney, Eileen R; Tomporowski, Phillip D; Boreham, Colin A G
2013-06-01
Both physical and cognitive factors are known to independently predict functional mobility in older people. However, the combined predictive value of both physical fitness and cognitive factors on functional mobility has been less investigated. The aim of the present study was to assess if cognitive executive functions moderate the role of physical fitness in determining functional mobility of older individuals. Fifty-seven 65- to 75-year-old healthy participants performed tests of functional mobility (habitual and maximal walking speed, maximal walking speed while picking up objects/stepping over obstacles), physical fitness (peak power, knee extensors torque, back/lower limb flexibility, aerobic fitness), and executive function (inhibition and cognitive flexibility). Maximal walking speeds were predicted by physical fitness parameters and their interaction with cognitive factors. Knee extensor torque emerged as the main predictor of all tested locomotor performances at maximal speed. The effect of peak power and back/lower limb flexibility was moderated by executive functions. In particular, inhibition and cognitive flexibility differed in the way in which they moderate the role of fitness. High levels of cognitive flexibility seem necessary to take advantage of leg power for walking at maximal speed. In contrast, high levels of inhibitory capacity seem to compensate for low levels of back/lower limb flexibility when picking up movements are added to a locomotor task. These findings may have important practical implications for the design and implementation of multi-component training programs aimed at optimizing functional abilities in older adults.
Hatef, Boshra; Ghanjal, Ali; Meftahi, Gholam Hossein; Askary-Ashtiani, Ahmadreza
2016-01-01
Background: Patients with type 2 diabetes mellitus (T2DM) are subject to progressive reduction of muscle mass and strength. The aim of this study was to assess muscle forces and electromyography (EMG) indices in short and long-term diabetes during an isokinetic exercise. Methods: The peak torque, work, mean power frequency (MPF) and root mean square (RMS) of knee flexors and extensors during 40 isokinetic knee extension-flexion repetitions with a velocity of 150 degree/s were recorded. 18 patients with less than 10 years with T2DM and 12 patients with equal and more than 10 years of disease were compared with 20 gender, body mass index, physical activity and peripheral circulation matched healthy controls. Results: The fatigue index and slope of line across the peak torque values of the knee flexor indicate that patients with long-term T2DM were significantly more resistant to fatigue in comparison with the two other groups (p<0.009). Whereas the MPF decrease during isokinetic protocol interact with grouping in the medial hamstring (p<0.042), but it was independent to groups in other muscles (p<0.0001). The increase of RMS after fatigue protocol interacted with sex for the medial hamstring and vastus lateralis (p<0.039) and interacted with group for the extensor muscles (p<0.045). Discussion & Conclusion: It seems that long-term T2DM cause some neuromuscular adaptations to maintain knee flexor muscle performance during functional activity especially postural control. PMID:27045412
Brunetti, O; Filippi, G M; Lorenzini, M; Liti, A; Panichi, R; Roscini, M; Pettorossi, V E; Cerulli, G
2006-11-01
Surgical reconstruction of the anterior cruciate ligament (ACL) may reduce, but it does not always eliminate, knee and body instability because of a persisting proprioceptive deficit. In order to enhance body stability, a new protocol of treatment has been proposed consisting of mechanical vibration (100 Hz frequency and < 20 microm amplitude) of the quadriceps muscle in the leg that has undergone ACL reconstruction. In our trials, stimulation was performed when the quadriceps muscle was kept isometrically contracted. Treatment was started one month after surgery. Vibration was applied for short periods over three consecutive days. Nine months after treatment, postural stability was re-evaluated with the subjects standing on one leg with open and with closed eyes. The postural stability of the subjects having undergone vibration treatment, standing on the operated leg was significantly improved one day after treatment when evaluated as mean of speed and elliptic area of the center of pressure. The improvement persisted and increased during the following weeks. Peak torques of the operated leg extensor muscles also increased and reached values close to that of the leg, which had not been operated. Conversely, the balance of the untreated subjects standing on the operated leg did not improve and the restoration of the extensor muscle peak torque was poor. It is concluded that short lasting proprioceptive activation by vibration may lead to a faster and more complete equilibrium recovery probably by permanently changing the network controlling knee posture.
Hasan, Z; Enoka, R M
1985-01-01
Since the moment arms for the elbow-flexor muscles are longest at intermediate positions of the elbow and shorter at the extremes of the range of motion, it was expected that the elbow torque would also show a peak at an intermediate angle provided the activity of the flexor muscles remained constant. We measured the isometric elbow torque at different elbow angles while the subject attempted to keep constant the electromyographic activity (EMG) of the brachioradialis muscle. The torque-angle relationship thus obtained exhibited a peak, as expected, but the shape of the relationship varied widely among subjects. This was due in part to differences in the variation of the biceps brachii EMG with elbow angle among the different subjects. The implications of these observations for the equilibrium-point hypothesis of movement were investigated as follows. The subject performed elbow movements in the presence of an external torque (which tended to extend the elbow joint) provided by a weight-and-pulley arrangement. We found in the case of flexion movements that invariably there was a transient increase in flexor EMG, as would seem necessary for initiating the movement. However, the steady-state EMG after the movement could be greater or less than the pre-movement EMG. Specifically, the least flexor EMG was required for equilibrium in the intermediate range of elbow angles, compared to the extremes of the range of motion. The EMG-angle relationship, however, varied with the muscle and the subject. The observation that the directions of change in the transient and the steady-state EMG are independent of each other militates against the generality of the equilibrium-point hypothesis. However, a form of the hypothesis which includes the effects of the stretch reflex is not contradicted by this observation.
Lepesqueur, Laura Soares; de Figueiredo, Viviane Maria Gonçalves; Ferreira, Leandro Lameirão; Sobrinho, Argemiro Soares da Silva; Massi, Marcos; Bottino, Marco Antônio; Nogueira Junior, Lafayette
2015-01-01
To determine the effect of maintaining torque after mechanical cycling of abutment screws that are coated with diamondlike carbon and coated with diamondlike carbon doped with diamond nanoparticles, with external and internal hex connections. Sixty implants were divided into six groups according to the type of connection (external or internal hex) and the type of abutment screw (uncoated, coated with diamondlike carbon, and coated with diamondlike carbon doped with diamond nanoparticles). The implants were inserted into polyurethane resin and crowns of nickel chrome were cemented on the implants. The crowns had a hole for access to the screw. The initial torque and the torque after mechanical cycling were measured. The torque values maintained (in percentages) were evaluated. Statistical analysis was performed using one-way analysis of variance and the Tukey test, with a significance level of 5%. The largest torque value was maintained in uncoated screws with external hex connections, a finding that was statistically significant (P = .0001). No statistically significant differences were seen between the groups with and without coating in maintaining torque for screws with internal hex connections (P = .5476). After mechanical cycling, the diamondlike carbon with and without diamond doping on the abutment screws showed no improvement in maintaining torque in external and internal hex connections.
Computing the motor torque of Escherichia coli.
Das, Debasish; Lauga, Eric
2018-06-13
The rotary motor of bacteria is a natural nano-technological marvel that enables cell locomotion by powering the rotation of semi-rigid helical flagellar filaments in fluid environments. It is well known that the motor operates essentially at constant torque in counter-clockwise direction but past work have reported a large range of values of this torque. Focusing on Escherichia coli cells that are swimming and cells that are stuck on a glass surface for which all geometrical and environmental parameters are known (N. C. Darnton et al., J. Bacteriol., 2007, 189, 1756-1764), we use two validated numerical methods to compute the value of the motor torque consistent with experiments. Specifically, we use (and compare) a numerical method based on the boundary integral representation of Stokes flow and also develop a hybrid method combining boundary element and slender body theory to model the cell body and flagellar filament, respectively. Using measured rotation speed of the motor, our computations predict a value of the motor torque in the range 440 pN nm to 829 pN nm, depending critically on the distance between the flagellar filaments and the nearby surface.
NASA Technical Reports Server (NTRS)
Pigeon, Pascale; Bortolami, Simone B.; DiZio, Paul; Lackner, James R.
2003-01-01
When reaching movements involve simultaneous trunk rotation, additional interaction torques are generated on the arm that are absent when the trunk is stable. To explore whether the CNS compensates for such self-generated interaction torques, we recorded hand trajectories in reaching tasks involving various amplitudes and velocities of arm extension and trunk rotation. Subjects pointed to three targets on a surface slightly above waist level. Two of the target locations were chosen so that a similar arm configuration relative to the trunk would be required for reaching to them, one of these targets requiring substantial trunk rotation, the other very little. Significant trunk rotation was necessary to reach the third target, but the arm's radial distance to the body remained virtually unchanged. Subjects reached at two speeds-a natural pace (slow) and rapidly (fast)-under normal lighting and in total darkness. Trunk angular velocity and finger velocity relative to the trunk were higher in the fast conditions but were not affected by the presence or absence of vision. Peak trunk velocity increased with increasing trunk rotation up to a maximum of 200 degrees /s. In slow movements, peak finger velocity relative to the trunk was smaller when trunk rotation was necessary to reach the targets. In fast movements, peak finger velocity was approximately 1.7 m/s for all targets. Finger trajectories were more curved when reaching movements involved substantial trunk rotation; however, the terminal errors and the maximal deviation of the trajectory from a straight line were comparable in slow and fast movements. This pattern indicates that the larger Coriolis, centripetal, and inertial interaction torques generated during rapid reaches were compensated by additional joint torques. Trajectory characteristics did not vary with the presence or absence of vision, indicating that visual feedback was unnecessary for anticipatory compensations. In all reaches involving trunk rotation, the finger movement generally occurred entirely during the trunk movement, indicating that the CNS did not minimize Coriolis forces incumbent on trunk rotation by sequencing the arm and trunk motions into a turn followed by a reach. A simplified model of the arm/trunk system revealed that additional interaction torques generated on the arm during voluntary turning and reaching were equivalent to < or =1.8 g (1 g = 9.81 m/s(2)) of external force at the elbow but did not degrade performance. In slow-rotation room studies involving reaching movements during passive rotation, Coriolis forces as small as 0.2 g greatly deflect movement trajectories and endpoints. We conclude that compensatory motor innervations are engaged in a predictive fashion to counteract impending self-generated interaction torques during voluntary reaching movements.
Pigeon, Pascale; Bortolami, Simone B; DiZio, Paul; Lackner, James R
2003-01-01
When reaching movements involve simultaneous trunk rotation, additional interaction torques are generated on the arm that are absent when the trunk is stable. To explore whether the CNS compensates for such self-generated interaction torques, we recorded hand trajectories in reaching tasks involving various amplitudes and velocities of arm extension and trunk rotation. Subjects pointed to three targets on a surface slightly above waist level. Two of the target locations were chosen so that a similar arm configuration relative to the trunk would be required for reaching to them, one of these targets requiring substantial trunk rotation, the other very little. Significant trunk rotation was necessary to reach the third target, but the arm's radial distance to the body remained virtually unchanged. Subjects reached at two speeds-a natural pace (slow) and rapidly (fast)-under normal lighting and in total darkness. Trunk angular velocity and finger velocity relative to the trunk were higher in the fast conditions but were not affected by the presence or absence of vision. Peak trunk velocity increased with increasing trunk rotation up to a maximum of 200 degrees /s. In slow movements, peak finger velocity relative to the trunk was smaller when trunk rotation was necessary to reach the targets. In fast movements, peak finger velocity was approximately 1.7 m/s for all targets. Finger trajectories were more curved when reaching movements involved substantial trunk rotation; however, the terminal errors and the maximal deviation of the trajectory from a straight line were comparable in slow and fast movements. This pattern indicates that the larger Coriolis, centripetal, and inertial interaction torques generated during rapid reaches were compensated by additional joint torques. Trajectory characteristics did not vary with the presence or absence of vision, indicating that visual feedback was unnecessary for anticipatory compensations. In all reaches involving trunk rotation, the finger movement generally occurred entirely during the trunk movement, indicating that the CNS did not minimize Coriolis forces incumbent on trunk rotation by sequencing the arm and trunk motions into a turn followed by a reach. A simplified model of the arm/trunk system revealed that additional interaction torques generated on the arm during voluntary turning and reaching were equivalent to < or =1.8 g (1 g = 9.81 m/s(2)) of external force at the elbow but did not degrade performance. In slow-rotation room studies involving reaching movements during passive rotation, Coriolis forces as small as 0.2 g greatly deflect movement trajectories and endpoints. We conclude that compensatory motor innervations are engaged in a predictive fashion to counteract impending self-generated interaction torques during voluntary reaching movements.
Hartigan, Erin; Aucoin, Jennifer; Carlson, Rita; Klieber-Kusak, Melanie; Murray, Thomas; Shaw, Bernadette; Lawrence, Michael
Weighted gait increases internal knee extension moment impulses (KEMI) in the anterior cruciate ligament-reconstructed (ACLR) limb; however, limb differences persist. (1) KEMI during normal gait will influence KEMI during weighted gait and (2) peak knee extension (PKE) torque and time to reach PKE torque will predict KEMI during gait tasks. Descriptive laboratory study. Twenty-four women and 14 men completed 3 gait tasks (unweighted, vest, sled) and strength testing after discharge from rehabilitation and clearance to return to sports. KEMI were calculated during the first 25% of stance. PKE torque and time to reach PKE torque were obtained using a dynamometer. Data on the ACLR limb and symmetry indices (SIs) were analyzed for each sex. Women presented with asymmetrical PKE torques and KEMI across tasks. There were three correlations noted for KEMI: between the walk and vest, walk and sled, and vest and sled tasks. Slower time to PKE torque predicted limb asymmetries across tasks and KEMI in the ACLR limb during the sled task. Men presented with asymmetrical PKE torques and KEMI during the sled task. There was a correlation noted for KEMI between walk and vest tasks only. During the sled task, ACLR limb time to PKE torque predicted KEMI in the ACLR limb and PKE torque SI predicted KEMI SI. Women use asymmetrical KEMI profiles during all gait tasks, and those with worse KEMI during walking have worse KEMI during weighted gait. Men have asymmetrical KEMI when sled towing, and these KEMIs do not correlate with KEMI during walking or vest tasks. PKE torque deficits persist when attempting to return to sports. Only men use gains in PKE torque to improve KEMI profiles. Although quicker PKE torque generation will increase KEMI in women, normalization of KEMI profiles will not occur by increasing rate of force development only. Gait retraining is recommended to correct asymmetrical KEMI profiles used across gait tasks in women.
2018-01-01
Objectives To evaluate the mechanical properties and metallurgical characteristics of the M3 Rotary and M3 Pro Gold files (United Dental). Materials and Methods One hundred and sixty new M3 Rotary and M3 Pro Gold files (sizes 20/0.04 and 25/0.04) were used. Torque and angle of rotation at failure (n = 20) were measured according to ISO 3630-1. Cyclic fatigue resistance was tested by measuring the number of cycles to failure in an artificial stainless steel canal (60° angle of curvature and a 5-mm radius). The metallurgical characteristics were investigated by differential scanning calorimetry. Data were analyzed using analysis of variance and the Student-Newman-Keuls test. Results Comparing the same size of the 2 different instruments, cyclic fatigue resistance was significantly higher in the M3 Pro Gold files than in the M3 Rotary files (p < 0.001). No significant difference was observed between the files in the maximum torque load, while a significantly higher angular rotation to fracture was observed for M3 Pro Gold (p < 0.05). In the DSC analysis, the M3 Pro Gold files showed one prominent peak on the heating curve and 2 prominent peaks on the cooling curve. In contrast, the M3 Rotary files showed 1 small peak on the heating curve and 1 small peak on the cooling curve. Conclusions The M3 Pro Gold files showed greater flexibility and angular rotation than the M3 Rotary files, without decrement of their torque resistance. The superior flexibility of M3 Pro Gold files can be attributed to their martensite phase. PMID:29765904
40 CFR Appendix B to Subpart E of... - Tables
Code of Federal Regulations, 2010 CFR
2010-07-01
... Variable-Speed Engines Test segment Mode number Engine speed 1 Observed torque 2 (percent of max. observed...'s specifications. Idle speed is specified by the manufacturer. 2 Torque (non-idle): Throttle fully open for 100 percent points. Other non-idle points: ± 2 percent of engine maximum value. Torque (idle...
Andrade, R J; Freitas, S R; Vaz, J R; Bruno, P M; Pezarat-Correia, P
2015-06-01
This study aimed to determine the influence of the head, upper trunk, and foot position on the passive knee extension (PKE) torque-angle response. PKE tests were performed in 10 healthy subjects using an isokinetic dynamometer at 2°/s. Subjects lay in the supine position with their hips flexed to 90°. The knee angle, passive torque, surface electromyography (EMG) of the semitendinosus and quadriceps vastus medialis, and stretch discomfort were recorded in six body positions during PKE. The different maximal active positions of the cervical spine (neutral; flexion; extension), thoracic spine (neutral; flexion), and ankle (neutral; dorsiflexion) were passively combined for the tests. Visual analog scale scores and EMG were unaffected by body segment positioning. An effect of the ankle joint was verified on the peak torque and knee maximum angle when the ankle was in the dorsiflexion position (P < 0.05). Upper trunk positioning had an effect on the knee submaximal torque (P < 0.05), observed as an increase in the knee passive submaximal torque when the cervical and thoracic spines were flexed (P < 0.05). In conclusion, other apparently mechanical unrelated body segments influence torque-angle response since different positions of head, upper trunk, and foot induce dissimilar knee mechanical responses during passive extension. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Torque characteristics of a 122-centimeter butterfly valve with a hydro/pneumatic actuator
NASA Technical Reports Server (NTRS)
Lin, F. N.; Moore, W. I.; Lundy, F. E.
1981-01-01
Actuating torque data from field testing of a 122-centimeter (48 in.) butterfly valve with a hydro/pneumatic actuator is presented. The hydraulic cylinder functions as either a forward or a reverse brake. Its resistance torque increases when the valve speeds up and decreases when the valve slows down. A reduction of flow resistance in the hydraulic flow path from one end of the hydraulic cylinder to the other will effectively reduce the hydraulic resistance torque and hence increase the actuating torque. The sum of hydrodynamic and friction torques (combined resistance torque) of a butterfly valve is a function of valve opening time. An increase in the pneumatic actuating pressure will result in a decrease in both the combined resistance torque and the actuator opening torque; however, it does shorten the valve opening time. As the pneumatic pressure increases, the valve opening time for a given configuration approaches an asymptotical value.
Uncontrolled Manifold Reference Feedback Control of Multi-Joint Robot Arms
Togo, Shunta; Kagawa, Takahiro; Uno, Yoji
2016-01-01
The brain must coordinate with redundant bodies to perform motion tasks. The aim of the present study is to propose a novel control model that predicts the characteristics of human joint coordination at a behavioral level. To evaluate the joint coordination, an uncontrolled manifold (UCM) analysis that focuses on the trial-to-trial variance of joints has been proposed. The UCM is a nonlinear manifold associated with redundant kinematics. In this study, we directly applied the notion of the UCM to our proposed control model called the “UCM reference feedback control.” To simplify the problem, the present study considered how the redundant joints were controlled to regulate a given target hand position. We considered a conventional method that pre-determined a unique target joint trajectory by inverse kinematics or any other optimization method. In contrast, our proposed control method generates a UCM as a control target at each time step. The target UCM is a subspace of joint angles whose variability does not affect the hand position. The joint combination in the target UCM is then selected so as to minimize the cost function, which consisted of the joint torque and torque change. To examine whether the proposed method could reproduce human-like joint coordination, we conducted simulation and measurement experiments. In the simulation experiments, a three-link arm with a shoulder, elbow, and wrist regulates a one-dimensional target of a hand through proposed method. In the measurement experiments, subjects performed a one-dimensional target-tracking task. The kinematics, dynamics, and joint coordination were quantitatively compared with the simulation data of the proposed method. As a result, the UCM reference feedback control could quantitatively reproduce the difference of the mean value for the end hand position between the initial postures, the peaks of the bell-shape tangential hand velocity, the sum of the squared torque, the mean value for the torque change, the variance components, and the index of synergy as well as the human subjects. We concluded that UCM reference feedback control can reproduce human-like joint coordination. The inference for motor control of the human central nervous system based on the proposed method was discussed. PMID:27462215
Tabassum, Afsheen; Meijer, Gert J; Walboomers, X Frank; Jansen, John A
2014-04-01
To investigate the influence of different surgical techniques on the primary and secondary implant stability using trabecular bone of goats as an implantation model. In the iliac crest of eight goats, 48 cylindrical-screw-type implants with a diameter of 4.2 mm (Dyna(®) ; Bergen op Zoom, the Netherlands) were installed, using three different surgical techniques: (i) 5% undersized, using a final drill diameter of 4 mm; (ii) 15% undersized, using a final drill diameter of 3.6 mm; and (iii) 25% undersized, using a final drill diameter of 3.2 mm. Peak insertion torque values were measured by a Digital(®) (MARK-10 Corporation, New York, NY, USA) torque gauge instrument during placement. At 3 weeks after implantation, removal torque was measured. Histomorphometrically, the peri-implant bone volume was measured in three zones; the inner zone (0-500 μm), the middle zone (500-1000 μm) and the outer zone (1000-1500 μm). Evaluation of the obtained data demonstrated no statistically significant difference between different surgical techniques regarding removal torque values. With respect to the percentage peri-implant bone volume (%BV), also no significant difference could be observed between all three applied surgical techniques for both the inner, middle and outer zone. However, irrespective of the surgical technique, it was noticed that the %BV was significantly higher for the inner zone as compared to middle and outer zone (P < 0.05) around the implant. At 3 weeks after implant installation, independent of the used undersized surgical technique, the %BV in the inner zone (0-500 μm) peri-implant area was improved due to both condensation of the surrounding bone as also the translocation of host bone particles along the implant surface. Surprisingly, no mechanical beneficial effect of the 25% undersized surgical technique could be observed as compared to the 5% or 15% undersized surgical technique to improve primary or secondary implant stability. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Smith, Nicole A; Turkyilmaz, Ilser
2014-09-01
When evaluating long-term implant success, clinicians have always been concerned with the gap at the implant-abutment junction, where bacteria can accumulate and cause marginal bone loss. However, little information regarding bacterial leakage at the implant-abutment junction, or microgap, is available. The purpose of this study was to evaluate sealing at 2 different implant-abutment interfaces under different screw torque values. Twenty sterile zirconia abutments and 20 sterile titanium abutments were screwed into 40 sterile implants and placed in test tubes. The ability of a bacterial mixture of Prevotella intermedia, Porphyromonas gingivalis, and Fusobacterium nucleatum to leak through an implant-titanium abutment seal under 20 and 35 Ncm torque values and an implant-zirconia abutment seal under 20 and 35 Ncm torque values was evaluated daily until leakage was noted. Once a unit demonstrated leakage, a specimen was plated. After 4 days, the number of colonies on each plate was counted with an electronic colony counter. Plating was used to verify whether or not bacterial leakage occurred and when leakage first occurred. The implant-abutment units were removed and rinsed with phosphate buffered saline solution and evaluated with a stereomicroscope. The marginal gap between the implant and the abutment was measured and correlated with the amount of bacterial leakage. The data were analyzed with ANOVA. Bacterial leakage was noted in all specimens, regardless of material or screw torque value. With titanium abutments, changing the screw torque value from 20 to 35 Ncm did not significantly affect the amount of bacterial leakage. However, with zirconia abutments, changing the screw torque value from 20 to 35 Ncm was statistically significant (P<.017). Overall, the marginal gap noted was larger at the zirconia-abutment interface (5.25 ±1.99 μm) than the titanium-abutment interface (12.38 ±3.73 μm), irrespective of the screw torque value. Stereomicroscopy revealed a nonuniform marginal gap in all specimens. The results of this study showed that, over time, bacteria will leak through the implant-abutment microgap at the implant-abutment interface. Implants with a titanium abutment demonstrate a smaller microgap than implants with a zirconia abutment. Tightening the zirconia abutment screw from 20 to 35 Ncm decreases the size of the microgap, which suggests a more intimate fit between the implant and the abutment. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
[Nutritional evaluation and physical functional ability in scleroderma patients].
Azevedo, Valderilio Feijó; Müller, Carolina de Souza; Rinaldi, Luciane; Bredt, Murilo Cézar; Giovanni, Karizianni; Pereira, Marcela Abou Chami; Volaco, Fernanda Copabianco
2009-01-01
Systemic Sclerosis (SSc) is an inflammatory disease that decreases functional capacity through muscular atrophy, skin sclerosis and loss of joint function. Scleroderma patients suffer from movement's restriction. In addition, the disease affects the nutritional status, compromising the quality of life in varying degrees. The gastrointestinal involvement appears to be the main responsible for the nutritional impairment. To evaluate the physical and nutritional status of patients with SSc. We conducted a cross-sectional and descriptive study in 20 patients with SSc. All patients were evaluated in Physioteraphy Clinic of the Catholic University of Paraná, from July 2003 to April 2004. The evaluation was performed by Bioimpedance Body (BIA), the questionnaires Nutritional Risk Assessment (Determine), Mini Nutritional Assessment of Aging and Health Assessment Questionnaire (HAQ) and Visual Analogue Scale (VAS) for pain. The work muscle ability was assessed by measuring the peak torque of flexor and extensor muscles of the elbow in the isokinetic dynamometer Cybex Norm model 7000. We have calculated the mean and standard deviation for each variable analyzed, in addition to the percentage of peak torque deficit. The values of the VAS ranged from zero to 97.8 mm (mean: 48.9 +/- 32.9 mm). The HAQ scores ranged from zero to 2.75 (average: 0.95 +/- 0.8). The average BMI was 22.4 +/- 3.9 kg / m2. The average deficit of mass was: 1.3 +/- 2.1 kg. Ten patients had high nutritional risk. 1 patient was malnourished and 15 were at high risk for malnutrition. The average peak torque to the muscle groups of elbows was 19.2 +/- 5 N / m to the flexor and 21.9 +/-6.6 N/m for the extensors, with an average deficit of 17% and 13% for the both groups. We found that SSc patients were in poor nutritional status and had decreased functional and physical capacity by the weakening of the muscles of the elbow demonstrated by the isokinetic evaluation. We concluded that our SSc patients were at high risk for malnutrition and this may indicate that scleroderma patients need a better nutritional orientation. We do consider that SSc patients also must be included in physical activity programs in order to achieve better physical performance.
Friction torque in thrust ball bearings grease lubricated
NASA Astrophysics Data System (ADS)
Ianuş, G.; Dumitraşcu, A. C.; Cârlescu, V.; Olaru, D. N.
2016-08-01
The authors investigated experimentally and theoretically the friction torque in a modified thrust ball bearing having only 3 balls operating at low axial load and lubricated with NGLI-00 and NGLI-2 greases. The experiments were made by using spin-down methodology and the results were compared with the theoretical values based on Biboulet&Houpert's rolling friction equations. Also, the results were compared with the theoretical values obtained with SKF friction model adapted for 3 balls. A very good correlation between experiments and Biboulet_&_Houpert's predicted results was obtained for the two greases. Also was observed that the theoretical values for the friction torque calculated with SKF model adapted for a thrust ball bearing having only 3 balls are smaller that the experimental values.
NASA Astrophysics Data System (ADS)
Baylor, L. R.
2016-10-01
ELM mitigation using high frequency D2 pellet ELM pacing has been demonstrated in ITER baseline scenario plasmas on DIII D with low rotation obtained with low NBI input torque. The ITER burning plasmas will have relatively low input torque and are expected to have low rotation. ELM mitigation by on-demand pellet ELM triggering has not been observed before in these conditions. New experiments on DIII-D in these conditions with 90 Hz D2 pellets have shown that significant mitigation of the divertor ELM peak heat flux by a factor of 8 is possible without detrimental effects to the plasma confinement. High-Z impurity accumulation is dramatically reduced at all input torques from 0.1 to 2.5 N-m. Fueling with high field side injection of D2 pellets has been employed to demonstrate that density buildup can be obtained simultaneously with ELM mitigation. The implications are that rapid pellet injection remains a promising technique to trigger on-demand ELMs in low rotating plasmas with greatly reduced peak flux while preventing impurity accumulation in ITER. Supported by the US DOE under DE-AC05-00OR22725, DE-FC02-04ER54698.
Mechanics of the taper integrated screwed-in (TIS) abutments used in dental implants.
Bozkaya, Dinçer; Müftü, Sinan
2005-01-01
The tapered implant-abutment interface is becoming more popular due to the mechanical reliability of retention it provides. Consequently, understanding the mechanical properties of the tapered interface with or without a screw at the bottom has been the subject of a considerable amount of studies involving experiments and finite element (FE) analysis. This paper focuses on the tapered implant-abutment interface with a screw integrated at the bottom of the abutment. The tightening and loosening torques are the main factors in determining the reliability and the stability of the attachment. Analytical formulas are developed to predict tightening and loosening torque values by combining the equations related to the tapered interface with screw mechanics equations. This enables the identification of the effects of the parameters such as friction, geometric properties of the screw, the taper angle, and the elastic properties of the materials on the mechanics of the system. In particular, a relation between the tightening torque and the screw pretension is identified. It was shown that the loosening torque is smaller than the tightening torque for typical values of the parameters. Most of the tightening load is carried by the tapered section of the abutment, and in certain combinations of the parameters the pretension in the screw may become zero. The calculations performed to determine the loosening torque as a percentage of tightening torque resulted in the range 85-137%, depending on the values of taper angle and the friction coefficient.
Hastings, Mary K; Mueller, Michael J; Sinacore, David R; Strube, Michael J; Crowner, Beth E; Johnson, Jeffrey E; Racette, Brad R
2012-05-01
High forefoot plantar pressure is associated with plantar ulcers in people with diabetes and peripheral neuropathy. The purpose of this pilot study was to determine the safety and efficacy of botulinum toxin A injected into the gastrocnemius-soleus muscles to reduce muscle strength and plantar pressure. This double blind, randomized clinical trial studied 17 people with diabetes mellitus, peripheral neuropathy and a forefoot plantar ulcer. Subjects were randomized into one of three groups receiving gastrocnemius-soleus muscle injections on the involved side with; 1) Saline (n = 5, weight =99± 21 kg), 2) 200-units of Botox® (n = 7, weight = 101± 5 kg), or 3) 300-units of Botox® (n = 5, weight = 129± 22 kg). Botox® dose was converted to units/kg, the majority received between 1.9 and 2.4 units/kg (n = 11) and one 3.2 units/kg. Plantarflexor peak torque and forefoot peak plantar pressure were quantified prior and 2 weeks post-injection. There were no complications from the injections. Plantarflexor peak torque on the involved side increased in the placebo and 300 groups (3± 4 Nm and 6± 10 Nm, respectively) and decreased -8± 11 Nm in the 200 group. There was no relationship between units/kg of Botox® for each subject and change in plantarflexor peak torque. Forefoot peak plantar pressure did not change in the placebo and 300 groups (0± 11 and 0± 5 N/cm(2), respectively) and decreased -4± 16 N/cm2 (4%) for the 200 group. There were no adverse events associated with the Botox® injections. This study was unable to determine the dose to consistently reduce plantarflexor strength and forefoot plantar pressure. Additional research is needed to investigate diabetes mellitus specific physiological changes and their impact of BoNT-A effectiveness in order to guide appropriate dosing.
The Influence of a Bout of Exertion on Novice Barefoot Running Dynamics
Hashish, Rami; Samarawickrame, Sachithra D.; Baker, Lucinda; Salem, George J.
2016-01-01
Barefoot, forefoot strike (FFS) running has recently risen in popularity. Relative to shod, rear-foot strike (RFS) running, employing a FFS is associated with heightened triceps surae muscle activation and ankle mechanical demand. Novice to this pattern, it is plausible that habitually shod RFS runners exhibit fatigue to the triceps surae when acutely transitioning to barefoot running, thereby limiting their ability to attenuate impact. Therefore, the purpose was to determine how habitually shod RFS runners respond to an exertion bout of barefoot running, operationally defined as a barefoot run 20% of mean daily running distance. Twenty-one RFS runners performed novice barefoot running, before and after exertion. Ankle peak torque, triceps surae EMG median frequency, foot-strike patterns, joint energy absorption, and loading rates were evaluated. Of the 21 runners, 6 maintained a RFS, 10 adopted a mid-foot strike (MFS), and 5 adopted a FFS during novice barefoot running. In-response to exertion, MFS and FFS runners demonstrated reductions in peak torque, median frequency, and ankle energy absorption, and an increase in loading rate. RFS runners demonstrated reductions in peak torque and loading rate. These results indicate that a short bout of running may elicit fatigue to novice barefoot runners, limiting their ability to attenuate impact. Key points In response to exertion, novice barefoot runners demonstrate fatigue to their soleus. In response to exertion, novice barefoot runners demonstrate a reduction in ankle energy absorption In response to exertion, novice barefoot runners demonstrate an increase in loading rate PMID:27274672
The Influence of a Bout of Exertion on Novice Barefoot Running Dynamics.
Hashish, Rami; Samarawickrame, Sachithra D; Baker, Lucinda; Salem, George J
2016-06-01
Barefoot, forefoot strike (FFS) running has recently risen in popularity. Relative to shod, rear-foot strike (RFS) running, employing a FFS is associated with heightened triceps surae muscle activation and ankle mechanical demand. Novice to this pattern, it is plausible that habitually shod RFS runners exhibit fatigue to the triceps surae when acutely transitioning to barefoot running, thereby limiting their ability to attenuate impact. Therefore, the purpose was to determine how habitually shod RFS runners respond to an exertion bout of barefoot running, operationally defined as a barefoot run 20% of mean daily running distance. Twenty-one RFS runners performed novice barefoot running, before and after exertion. Ankle peak torque, triceps surae EMG median frequency, foot-strike patterns, joint energy absorption, and loading rates were evaluated. Of the 21 runners, 6 maintained a RFS, 10 adopted a mid-foot strike (MFS), and 5 adopted a FFS during novice barefoot running. In-response to exertion, MFS and FFS runners demonstrated reductions in peak torque, median frequency, and ankle energy absorption, and an increase in loading rate. RFS runners demonstrated reductions in peak torque and loading rate. These results indicate that a short bout of running may elicit fatigue to novice barefoot runners, limiting their ability to attenuate impact. Key pointsIn response to exertion, novice barefoot runners demonstrate fatigue to their soleus.In response to exertion, novice barefoot runners demonstrate a reduction in ankle energy absorptionIn response to exertion, novice barefoot runners demonstrate an increase in loading rate.
Test-Retest Reliability of Innovated Strength Tests for Hip Muscles
Meyer, Christophe; Corten, Kristoff; Wesseling, Mariska; Peers, Koen; Simon, Jean-Pierre; Jonkers, Ilse; Desloovere, Kaat
2013-01-01
The burden of hip muscles weakness and its relation to other impairments has been well documented. It is therefore a pre-requisite to have a reliable method for clinical assessment of hip muscles function allowing the design and implementation of a proper strengthening program. Motor-driven dynamometry has been widely accepted as the gold-standard for lower limb muscle strength assessment but is mainly related to the knee joint. Studies focusing on the hip joint are less exhaustive and somewhat discrepant with regard to optimal participants position, consequently influencing outcome measures. Thus, we aimed to develop a standardized test setup for the assessment of hip muscles strength, i.e. flexors/extensors and abductors/adductors, with improved participant stability and to define its psychometric characteristics. Eighteen participants performed unilateral isokinetic and isometric contractions of the hip muscles in the sagittal and coronal plane at two separate occasions. Peak torque and normalized peak torque were measured for each contraction. Relative and absolute measures of reliability were calculated using the intraclass correlation coefficient and standard error of measurement, respectively. Results from this study revealed higher levels of between-day reliability of isokinetic/isometric hip abduction/flexion peak torque compared to existing literature. The least reliable measures were found for hip extension and adduction, which could be explained by a less efficient stabilization technique. Our study additionally provided a first set of reference normalized data which can be used in future research. PMID:24260550
Ferreira, Gustavo Nunes Tasca; Teixeira-Salmela, Luci Fuscaldi; Guimarães, Cristiano Queiroz
2007-07-01
Studies that investigated possible correlations between flexibility and muscular performance are scarce in the literature. Therefore, the purpose of this study was to investigate the impact of a program of static stretching on the flexibility of the hamstrings and on muscular performance of the knee flexors and extensors. Pre-post experimental design. University laboratory. Thirty subjects aged 22.8 +/- 4.9 years with bilaterally shortened hamstrings. Using a protocol that has been previously described, the intervention consisted of 30 sessions of static stretching, performed bilaterally five times a week for 6 weeks. Measures of knee range of motion and isokinetic muscular performance (peak torque, angle of peak torque, and work) of knee flexors and extensors at speeds of 60 and 300 degrees/s. After intervention, significant gains in measures of flexibility (P < 0.0001) were observed, with an average gain of the knee-extension angle of 12.6 degrees, ranging from -1.2 to 30.7 degrees. In addition, we found significant increases in the following parameters of muscular performance: angle of peak torque of hamstrings at 60 and 300 degrees/s (P < 0.0001 and 0.018) and for work at 60 and 300 degrees/s for knee flexors (P = 0.012 and 0.005) and for knee extensors (P < 0.0001). The intervention resulted in gains in measures of flexibility, and these gains had a positive impact on some parameters of muscular performance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Masset, F. S.; Casoli, J., E-mail: masset@fis.unam.m, E-mail: jules.casoli@cea.f, E-mail: masset@fis.unam.m
2010-11-10
We provide torque formulae for low-mass planets undergoing type I migration in gaseous disks. These torque formulae put special emphasis on the horseshoe drag, which is prone to saturation: the asymptotic value reached by the horseshoe drag depends on a balance between coorbital dynamics (which tends to cancel out or saturate the torque) and diffusive processes (which tend to restore the unperturbed disk profiles, thereby desaturating the torque). We entertain the question of this asymptotic value and derive torque formulae that give the total torque as a function of the disk's viscosity and thermal diffusivity. The horseshoe drag features twomore » components: one that scales with the vortensity gradient and another that scales with the entropy gradient and constitutes the most promising candidate for halting inward type I migration. Our analysis, which is complemented by numerical simulations, recovers characteristics already noted by numericists, namely, that the viscous timescale across the horseshoe region must be shorter than the libration time in order to avoid saturation and that, provided this condition is satisfied, the entropy-related part of the horseshoe drag remains large if the thermal timescale is shorter than the libration time. Side results include a study of the Lindblad torque as a function of thermal diffusivity and a contribution to the corotation torque arising from vortensity viscously created at the contact discontinuities that appear at the horseshoe separatrices. For the convenience of the reader mostly interested in the torque formulae, Section 8 is self-contained.« less
NASA Astrophysics Data System (ADS)
Li, Mingming; Li, Jiheng; Bao, Xiaoqian; Mu, Xing; Gao, Xuexu
2017-07-01
The results of a study on the suitability of Fe-Ga alloys for torque sensor applications are presented. A Fe81Ga19 rod with a ⟨100⟩ preferred orientation along the length direction is prepared for the torque shaft and as the electromagnetic induction sensitive element, which is wound with three coils for signal excitation, signal pickup, and applied bias magnetic field, respectively. An apparent decrease in the induced voltage signal (peak voltage) of 3.88 mV is observed as the torque loading is 50 N m in the presence of a sine excitation signal (10 V, 1 kHz) and a bias current of 0.5 A. Meanwhile, a good repeatability and stress sensitivity are obtained, especially in the low torque range. These behaviors stem from the stress induced decrease in the magnetic permeability and the rotation of the arranged magnetic moment. Here, we use the Fe81Ga19 alloy as the shaft material; nevertheless, in practical use, the same effect can be achieved by forming a Fe-Ga layer with large magnetostriction on the surface of the torsion shaft. This work shows the prospect of Fe-Ga alloys for non-contact torque sensing, for the large magnetostriction and high sensitivity of magnetization to stress.
40 CFR 86.1333-90 - Transient test cycle generation.
Code of Federal Regulations, 2012 CFR
2012-07-01
... zero percent speed specified in the engine dynamometer schedules (appendix I (f)(1), (f)(2), or (f)(3... feedback torque equal to zero (using, for example, clutch disengagement, speed to torque control switching... reference speed and reference torque are zero percent values. For each idle segment that is ten seconds or...
40 CFR 86.1333-90 - Transient test cycle generation.
Code of Federal Regulations, 2013 CFR
2013-07-01
... zero percent speed specified in the engine dynamometer schedules (appendix I (f)(1), (f)(2), or (f)(3... feedback torque equal to zero (using, for example, clutch disengagement, speed to torque control switching... reference speed and reference torque are zero percent values. For each idle segment that is ten seconds or...
40 CFR 86.1333-90 - Transient test cycle generation.
Code of Federal Regulations, 2011 CFR
2011-07-01
... zero percent speed specified in the engine dynamometer schedules (appendix I (f)(1), (f)(2), or (f)(3... feedback torque equal to zero (using, for example, clutch disengagement, speed to torque control switching... reference speed and reference torque are zero percent values. For each idle segment that is ten seconds or...
Change in the contractile behavior of muscle fibers in subjects with primary muscle dysfunction.
Back, Claudio Gregório Nuernberg; Benedini-Elias, Priscila C O; Mattiello, Stela M; Sobreira, Claudia; Martinez, Edson Z; Mattiello-Sverzut, Ana Claudia
2013-01-01
The mechanical and metabolic characteristics of skeletal muscle fibers can interfere with muscle contractile performance in healthy subjects. Few studies have investigated the degree of association between muscle function and muscle fiber morphology in patients with myopathy. A biopsy was obtained from the left biceps brachii muscle of 12 subjects with myopathic disorders. The relative cross-sectional area of type 2 fibers and their subtypes was determined by the ATPase technique. Relative torque (RT) was calculated by dividing isokinetic elbow flexion peak torque (PT) values (90 and 180° s-1) by isometric PT values. Correlations were analyzed using Spearman's coefficient (r). The relative cross-sectional area of type 2b fibers was positively correlated with RT90 (r = 0.71, P = 0.009) and RT180 (r = 0.73, P = 0.007). The relative cross-sectional area of type 2a fibers showed a moderate and negative correlation with RT180 (r = -0.62, P = 0.03) and a low correlation with RT90 (r = -0.57, P = 0.05). In contrast to healthy subjects, patients with myopathy presented changes in the contractile behavior of type 2a fibers and compensatory adaptations in type 2b fibers. The results suggest that RT in combination with morphometric parameters provides data regarding muscle function in patients with myopathic disorders and can contribute to the establishment of therapeutic exercises.
Conchola, Eric C; Thiele, Ryan M; Palmer, Ty B; Smith, Doug B; Thompson, Brennan J
2015-05-01
The aim of this study was to examine the effects of a medium-intensity high-volume vs. explosive squat protocol on the postexercise time course responses of maximal and rapid strength of the knee extensors. Seventeen resistance-trained men (mean ± SD: age = 22.0 ± 2.6 years) performed maximal voluntary contractions (MVCs) of the knee extensors before and after performing a squat workout using either a low-intensity fast velocity (LIFV) (5 × 16 at 40% 1 repetition maximum) or a traditional high-intensity slow velocity (TISV) (5 × 8 at 80% 1RM) exercise protocol. For each MVC, peak torque (PT), peak rate of torque development (RTDpeak), absolute (RTDabs), and relative RTD (RTDnorm) at early (0-50 milliseconds) and late (100-200 milliseconds) phases of muscle contraction were examined at pre- (Pre) and post-exercise at 0, 7, 15, and 30 (Post0...30) minutes. There were no intensity × time interactions for any variables (p = 0.098-0.832). Peak torque was greater at Pre than Post0 and Post7 (p = 0.001-0.016) but was not greater than Post15 and Post30 (p = 0.010-0.189). RTDpeak and early absolute RTD (RTD50abs) were greater at Pre than all postexercise time phases (p = 0.001-0.050); however, later absolute RTD (RTD100-200abs) was only greater at Pre than Post0 and Post30 (p = 0.013-0.048). Early relative RTD (RTD50norm) was only higher at Pre compared with Post0 (p = 0.023), whereas no differences were observed for later relative RTD (RTD100-200norm) (p = 0.920-0.990). Low-intensity fast velocity and TISV squat protocols both yielded acute decreases in maximal and rapid strength capacities following free-weight squats, with rapid strength showing slower recovery characteristics than maximal strength.
Functional outcomes of conservatively managed acute ruptures of the Achilles tendon.
Lawrence, J E; Nasr, P; Fountain, D M; Berman, L; Robinson, A H N
2017-01-01
This prospective cohort study aims to determine if the size of the tendon gap following acute rupture of the Achilles tendon shows an association with the functional outcome following non-operative treatment. All patients presenting within two weeks of an acute unilateral rupture of the Achilles tendon between July 2012 and July 2015 were considered for the study. In total, 38 patients (nine female, 29 male, mean age 52 years; 29 to 78) completed the study. Dynamic ultrasound examination was performed to confirm the diagnosis and measure the gap between ruptured tendon ends. Outcome was assessed using dynamometric testing of plantarflexion and the Achilles tendon Total Rupture score (ATRS) six months after the completion of a rehabilitation programme. Patients with a gap ≥ 10 mm with the ankle in the neutral position had significantly greater peak torque deficit than those with gaps < 10 mm (mean 23.3%; 7% to 52% vs 14.3%; 0% to 47%, p = 0.023). However, there was no difference in ATRS between the two groups (mean score 87.2; 74 to 100 vs 87.4; 68 to 97, p = 0.467). There was no significant correlation between gap size and torque deficit (τ = 0.103), suggesting a non-linear relationship. There was also no significant correlation between ATRS and peak torque deficit (τ = -0.305). This is the first study to identify an association between tendon gap and functional outcome in acute rupture of the Achilles tendon. We have identified 10 mm as a gap size at which deficits in plantarflexion strength become significantly greater, however, the precise relationship between gap size and plantarflexion strength remains unclear. Large, multicentre studies will be needed to clarify this relationship and identify population subgroups in whom deficits in peak torque are reflected in patient-reported outcome measures. Cite this article: Bone Joint J 2017;99-B:87-93. ©2017 The British Editorial Society of Bone & Joint Surgery.
Analysis and testing of a space crane articulating joint testbed
NASA Technical Reports Server (NTRS)
Sutter, Thomas R.; Wu, K. Chauncey
1992-01-01
The topics are presented in viewgraph form and include: space crane concept with mobile base; mechanical versus structural articulating joint; articulating joint test bed and reference truss; static and dynamic characterization completed for space crane reference truss configuration; improved linear actuators reduce articulating joint test bed backlash; 1-DOF space crane slew maneuver; boom 2 tip transient response finite element dynamic model; boom 2 tip transient response shear-corrected component modes torque driver profile; peak root member force vs. slew time torque driver profile; and open loop control of space crane motion.
Kuenze, Christopher; Eltouhky, Moataz; Thomas, Abbey; Sutherlin, Mark; Hart, Joseph
2016-05-01
Collecting torque data using a multimode dynamometer is common in sports-medicine research. The error in torque measurements across multiple sites and dynamometers has not been established. To assess the validity of 2 calibration protocols across 3 dynamometers and the error associated with torque measurement for each system. Observational study. 3 university laboratories at separate institutions. 2 Biodex System 3 dynamometers and 1 Biodex System 4 dynamometer. System calibration was completed using the manufacturer-recommended single-weight method and an experimental calibration method using a series of progressive weights. Both calibration methods were compared with a manually calculated theoretical torque across a range of applied weights. Relative error, absolute error, and percent error were calculated at each weight. Each outcome variable was compared between systems using 95% confidence intervals across low (0-65 Nm), moderate (66-110 Nm), and high (111-165 Nm) torque categorizations. Calibration coefficients were established for each system using both calibration protocols. However, within each system the calibration coefficients generated using the single-weight (System 4 = 2.42 [0.90], System 3a = 1.37 [1.11], System 3b = -0.96 [1.45]) and experimental calibration protocols (System 4 = 3.95 [1.08], System 3a = -0.79 [1.23], System 3b = 2.31 [1.66]) were similar and displayed acceptable mean relative error compared with calculated theoretical torque values. Overall, percent error was greatest for all 3 systems in low-torque conditions (System 4 = 11.66% [6.39], System 3a = 6.82% [11.98], System 3b = 4.35% [9.49]). The System 4 significantly overestimated torque across all 3 weight increments, and the System 3b overestimated torque over the moderate-torque increment. Conversion of raw voltage to torque values using the single-calibration-weight method is valid and comparable to a more complex multiweight calibration process; however, it is clear that calibration must be done for each individual system to ensure accurate data collection.
Hip joint kinetics in the table tennis topspin forehand: relationship to racket velocity.
Iino, Yoichi
2018-04-01
The purpose of this study was to determine hip joint kinetics during a table tennis topspin forehand, and to investigate the relationship between the relevant kinematic and kinetic variables and the racket horizontal and vertical velocities at ball impact. Eighteen male advanced table tennis players hit cross-court topspin forehands against backspin balls. The hip joint torque and force components around the pelvis coordinate system were determined using inverse dynamics. Furthermore, the work done on the pelvis by these components was also determined. The peak pelvis axial rotation velocity and the work done by the playing side hip pelvis axial rotation torque were positively related to the racket horizontal velocity at impact. The sum of the work done on the pelvis by the backward tilt torques and the upward joint forces was positively related to the racket vertical velocity at impact. The results suggest that the playing side hip pelvis axial rotation torque exertion is important for acquiring a high racket horizontal velocity at impact. The pelvis backward tilt torques and upward joint forces at both hip joints collectively contribute to the generation of the racket vertical velocity, and the mechanism for acquiring the vertical velocity may vary among players.
2006-04-01
relevant to TWV is focused on permanent magnet motors , often wheel mounted. Wound rotor motors provide substantially different design and control...options than permanent magnet motors , at the expense of additional cooling requirements. Their benefits include higher peak torque and less sensitivity
Stübinger, Stefan; Waser, Jasmin; Hefti, Thomas; Drechsler, Anika; Sidler, Michéle; Klein, Karina; von Rechenberg, Brigitte; Schlottig, Falko
2015-05-01
The aim of this study was to evaluate the clinical performance of local cancellous bone amelioration by a 70:30 poly-(L-lactide-co-D,L-Lacide) copolymer with two different implant designs on primary stability and after 4 and 12 weeks of healing time. In six sheep, n = 36 implants (TH) with a conditioned, sandblasted, thermal acid-etched micro-rough surface and n = 36 implants (NB) with a highly crystalline and phosphate-enriched anodized titanium oxide surface were placed in the pelvic bone. Using an ultrasound-based process named Constant Amelioration Process (CAP), half of peri-implant trabecular bone structures were locally tested with 70:30 poly-(L-lactide-co-D,L-Lacide) copolymer in both implant groups, TH and NB. The CAP technology employs ultrasonic energy to liquefy 70:30 poly-(L-lactide-co-D,L-Lacide) which enters the inter-trabecular space, leading to local reinforcement of the cancellous bone structure after solidification of the copolymer. The CAP test group was compared with reference implants placed with the conventional site preparation according to the manufacturers' description. Primary stability was assessed by the measurement of torque-in values and implant stability quotient (ISQ; n = 18 per group). Secondary stability was analyzed by biomechanical removal torque testing after 4 and 12 weeks (n = 9 per group). Insertion torque value (23.3 N cm ± 13.6) of reference TH implants demonstrated a statistically significant (P = 0.00) difference in comparison with test TH implants (41.9 N cm ± 19.5). Reference NB implants revealed a statistically significant (P = 0.03) lower insertion torque value (23.7 N cm ± 13.5) than test NB implants (39.7 N cm ± 18.6). ISQ values increased for all implants from initial implant placement until sacrifice at 12 weeks. Reference TH implants tended to result in an increase in torque values from 4 weeks (181.9 N cm ± 22.8) to 12 weeks (225.7 N cm ± 47.4). This trend could be also proven for implants of test sites (4 week: 176.8 N cm ± 24.1; 12 week: 201.5 N cm ± 53.4). For reference, NB implants a non-significant increase in removal torque values from 4 weeks (146. 7 N cm ± 18.0) to 12 weeks (170.2 N cm ± 40.4) was observed. Removal torque values of test NB implants did not increase from 4 weeks (153.3 N cm ± 21.5) to 12 weeks (146.1 N cm ± 37.5). Biomechanical data proved significantly enhanced primary stability of dental implants after local amelioration without long-term sequelae and irrespective of implant design. After 4- and 12-week healing time, removal torque of locally test implants was as high as for control implants, and osseointegration was therefore not influenced by the CAP process. No correlation between ISQ values and torque values was found. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Intramuscular pressure and torque during isometric, concentric and eccentric muscular activity
NASA Technical Reports Server (NTRS)
Styf, J.; Ballard, R.; Aratow, M.; Crenshaw, A.; Watenpaugh, D.; Hargens, A. R.
1995-01-01
Intramuscular pressures, electromyography (EMG) and torque generation during isometric, concentric and eccentric maximal isokinetic muscle activity were recorded in 10 healthy volunteers. Pressure and EMG activity were continuously and simultaneously measured side by side in the tibialis anterior and soleus muscles. Ankle joint torque and position were monitored continuously by an isokinetic dynamometer during plantar flexion and dorsiflexion of the foot. The increased force generation during eccentric muscular activity, compared with other muscular activity, was not accompanied by higher intramuscular pressure. Thus, this study demonstrated that eccentric muscular activity generated higher torque values for each increment of intramuscular pressure. Intramuscular pressures during antagonistic co-activation were significantly higher in the tibilis anterior muscle (42-46% of maximal agonistic activity) compared with the soleus muscle (12-29% of maximal agonistic activity) and was largely due to active recruitment of muscle fibers. In summary, eccentric muscular activity creates higher torque values with no additional increase of the intramuscular pressure compared with concentric and isometric muscular activity.
Peripheral arterial disease decreases muscle torque and functional walking capacity in elderly.
Dziubek, Wioletta; Bulińska, Katarzyna; Stefańska, Małgorzata; Woźniewski, Marek; Kropielnicka, Katarzyna; Jasiński, Tomasz; Jasiński, Ryszard; Pilch, Urszula; Dąbrowska, Grażyna; Skórkowska-Telichowska, Katarzyna; Wojcieszczyk-Latos, Joanna; Kałka, Dariusz; Janus, Agnieszka; Zywar, Katarzyna; Paszkowski, Rafał; Szuba, Andrzej
2015-08-01
The aim of this study is to compare values of force-velocity and functional walking capacity in elderly patients with intermittent claudication with respect to the control group. The study involved 135 individuals: 85-peripheral arterial disease (PAD) group diagnosed with stage II chronic lower limb ischemia, according to Fontaine's classification, and 50-control group. The studies included an assessment of walking capacity using a six-minute walk test (6MWT) and measurement of force-velocity parameters (peak torque-PTQ, total work-TW, average power-AVGP) of the lower limbs obtained by means of a functional dynamometry under isokinetic conditions. The peripheral arterial disease group is characterized by significantly lower values of force-velocity parameters compared to the control group (p<0.005). Walking capacity in this group is significantly reduced due to significant differences in the distance covered (p<0.0001), walking speed (p<0.01), and its intensity (p<0.01). Further, a positive correlation was found between the maximum distance specified in the six-minute walk test and lower limb muscle strength in the isokinetic test. Mean values of all force-velocity parameters and walk distance were significantly higher in the control group than in the peripheral arterial disease group. In the PAD group, in both men and women, the value of the agonist/antagonist ratio of both lower limbs are lower in men and women comparing to the control group. A rehabilitation program for patients with intermittent claudication must consider exercises improving strength, exercise capacity, and endurance in patients with PAD. Copyright © 2015 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.
VHDL-AMS modelling and simulation of a planar electrostatic micromotor
NASA Astrophysics Data System (ADS)
Endemaño, A.; Fourniols, J. Y.; Camon, H.; Marchese, A.; Muratet, S.; Bony, F.; Dunnigan, M.; Desmulliez, M. P. Y.; Overton, G.
2003-09-01
System level simulation results of a planar electrostatic micromotor, based on analytical models of the static and dynamic torque behaviours, are presented. A planar variable capacitance (VC) electrostatic micromotor designed, fabricated and tested at LAAS (Toulouse) in 1995 is simulated using the high level language VHDL-AMS (VHSIC (very high speed integrated circuits) hardware description language-analog mixed signal). The analytical torque model is obtained by first calculating the overlaps and capacitances between different electrodes based on a conformal mapping transformation. Capacitance values in the order of 10-16 F and torque values in the order of 10-11 N m have been calculated in agreement with previous measurements and simulations from this type of motor. A dynamic model has been developed for the motor by calculating the inertia coefficient and estimating the friction-coefficient-based values calculated previously for other similar devices. Starting voltage results obtained from experimental measurement are in good agreement with our proposed simulation model. Simulation results of starting voltage values, step response, switching response and continuous operation of the micromotor, based on the dynamic model of the torque, are also presented. Four VHDL-AMS blocks were created, validated and simulated for power supply, excitation control, micromotor torque creation and micromotor dynamics. These blocks can be considered as the initial phase towards the creation of intellectual property (IP) blocks for microsystems in general and electrostatic micromotors in particular.
Cardoso, Mayra; Torres, Marcelo Ferreira; Lourenço, Eduardo José Veras; de Moraes Telles, Daniel; Rodrigues, Renata Cristina Silveira; Ribeiro, Ricardo Faria
2012-04-01
The aim of this study was to evaluate the variation in removal torque of implant prosthetic abutment screws after successive tightening and loosening cycles, in addition to evaluating the influence of the hexagon at the abutment base on screw removal torque. Twenty hexagonal abutments were tightened to 20 regular external hex implants with a titanium alloy screw, with an insertion torque of 32 N cm, measured with a digital torque gauge. The implant/abutment/screw assemblies were divided into two groups: (1) abutments without hexagon at the base and (2) abutments with a hexagon at the base. Each assembly received a provisional restoration and was submitted to mechanical loading cycles. After this, the screws were removed and the removal torque was measured. This sequence was repeated 10 times, then the screw was replaced by a new one, and another cycle was performed. Linear regression analysis was performed. Removal torque values tended to decrease as the number of insertion/removal cycles increased, for both groups. Comparisons of the slopes and the intercepts between groups showed no statistical difference. There was no significant difference between the mean values of last five cycles and the 11th cycle. Within the limitations of this in vitro study, it was concluded that (1) repeated insertion/removal cycles promoted gradual reduction in removal torque of screws, (2) replacing the screw with a new one after 10 cycles did not increase resistance to loosening, and (3) removal of the hexagon from the abutment base had no effect on the removal torque of the screws. © 2011 John Wiley & Sons A/S.
NASA Astrophysics Data System (ADS)
Goryca, Zbigniew; Paduszyński, Kamil; Pakosz, Artur
2018-03-01
This paper presents the results of field calculations of cogging torque for a 12-pole torque motor with an 18-slot stator. A constant angular velocity magnet and the same size gap between n-1 magnets were assumed. In these conditions, the effect of change of the n-th gap between magnets on the cogging torque was tested. Due to considerable length of the machine the calculations were performed using a 2D model. The n-th gap for which the cogging torque assumed the lowest value was evaluated. The cogging torque of the machine with symmetrical magnetic circuit (the same size of gap between magnets) was compared to the one of the asymmetrical machine. With proper choice of asymmetry, the cogging torque for the machine decreased by four times.
NASA Technical Reports Server (NTRS)
Hodge, W. F.
1972-01-01
A numerical evaluation and an analysis of the effects of environmental disturbance torques on the attitude of a hexagonal cylinder rolling wheel spacecraft were performed. The resulting perturbations caused by five such torques were found to be very small and exhibited linearity such that linearized equations of motion yielded accurate results over short periods and the separate perturbations contributed by each torque were additive in the sense of superposition. Linearity of the torque perturbations was not affected by moderate system design changes and persisted for torque-to-angular momentum ratios up to 100 times the nominal expected value. As these conditions include many possible applications, similar linear behavior might be anticipated for other rolling-wheel spacecraft.
Zimmer, Bernd; Sino, Hiba
2018-03-19
To analyze common values of bracket torque (Andrews, Roth, MBT, Ricketts) for their validity in achieving incisor inclinations that are considered normal by different cephalometric standards. Using the equations developed in part 1 (eU1 (BOP) = 90° - BT (U1) - TCA (U1) + α 1 - α 2 and eL1 (BOP) = 90° - BT (L1) - TCA (L1) + β 1 - β 2 ) (abbreviations see part 1) and the mean values (± SD) obtained as statistical measures in parts 1 and 2 of the study (α 1 and β 1 [1.7° ± 0.7°], α 2 [3.6° ± 0.3°], β 2 [3.2° ± 0.4°], TCA (U1) [24.6° ± 3.6°] and TCA (L1) [22.9° ± 4.3°]) expected (= theoretically anticipated) values were calculated for upper and lower incisors (U1 and L1) and compared to targeted (= cephalometric norm) values. For U1, there was no overlapping between the ranges of expected and targeted values, as the lowest targeted value of (58.3°; Ricketts) was higher than the highest expected value (56.5°; Andrews) relative to the bisected occlusal plane (BOP). Thus all of these torque systems will aim for flatter inclinations than prescribed by any of the norm values. Depending on target values, the various bracket systems fell short by 1.8-5.5° (Andrews), 6.8-10.5° (Roth), 11.8-15.5° (MBT), or 16.8-20.5° (Ricketts). For L1, there was good agreement of the MBT system with the Ricketts and Björk target values (Δ0.1° and Δ-0.8°, respectively), and both the Roth and Ricketts systems came close to the Bergen target value (both Δ2.3°). Depending on target values, the ranges of deviation for L1 were 6.3-13.2° for Andrews (Class II prescription), 2.3°-9.2° for Roth, -3.7 to -3.2° for MBT, and 2.3-9.2° for Ricketts. Common values of upper incisor bracket torque do not have acceptable validity in achieving normal incisor inclinations. A careful selection of lower bracket torque may provide satisfactory matching with some of the targeted norm values.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ekşi, K. Y.; Andaç, I. C.; Çıkıntoğlu, S.
The recently discovered rotationally powered pulsar PSR J1640–4631 is the first to have a braking index measured, with high enough precision, that is greater than 3. An inclined magnetic rotator in vacuum or plasma would be subject not only to spin-down but also to an alignment torque. The vacuum model can address the braking index only for an almost orthogonal rotator, which is incompatible with the single-peaked pulse profile. The magnetic dipole model with the corotating plasma predicts braking indices between 3 and 3.25. We find that the braking index of 3.15 is consistent with two different inclination angles, 18.°5more » ± 3° and 56° ± 4°. The smaller angle is preferred given that the pulse profile has a single peak and the radio output of the source is weak. We infer the change in the inclination angle to be at the rate −0.°23 per century, three times smaller in absolute value than the rate recently observed for the Crab pulsar.« less
Evaluating transient performance of servo mechanisms by analysing stator current of PMSM
NASA Astrophysics Data System (ADS)
Zhang, Qing; Tan, Luyao; Xu, Guanghua
2018-02-01
Smooth running and rapid response are the desired performance goals for the transient motions of servo mechanisms. Because of the uncertain and unobservable transient behaviour of servo mechanisms, it is difficult to evaluate their transient performance. Under the effects of electromechanical coupling, the stator current signals of a permanent-magnet synchronous motor (PMSM) potentially contain the performance information regarding servo mechanisms in use. In this paper, a novel method based on analysing the stator current of the PMSM is proposed for quantifying the transient performance. First, a vector control model is constructed to simulate the stator current behaviour in the transient processes of consecutive speed changes, consecutive load changes, and intermittent start-stops. It is discovered that the amplitude and frequency of the stator current are modulated by the transient load torque and motor speed, respectively. The stator currents under different performance conditions are also simulated and compared. Then, the stator current is processed using a local means decomposition (LMD) algorithm to extract the instantaneous amplitude and instantaneous frequency. The sample entropy of the instantaneous amplitude, which reflects the complexity of the load torque variation, is calculated as a performance indicator of smooth running. The peak-to-peak value of the instantaneous frequency, which defines the range of the motor speed variation, is set as a performance indicator of rapid response. The proposed method is applied to both simulated data in an intermittent start-stops process and experimental data measured for a batch of servo turrets for turning lathes. The results show that the performance evaluations agree with the actual performance.
Cai, Congcong; Kong, Pui W
2015-06-01
Controlled laboratory study, cross-sectional. To compare lumbar extensor muscle fatigability, lumbar stabilizing muscle activation, and lower-limb strength between male and female runners with chronic low back pain (LBP) and healthy runners. Little is known about muscle performance in runners with chronic LBP. Eighteen recreational runners with chronic LBP (9 men, 9 women; mean age, 27.8 years) and 18 healthy recreational runners (9 men, 9 women; mean age, 24.6 years) were recruited. The median frequency slopes for bilateral iliocostalis and longissimus were calculated from electromyographic signals captured during a 2-minute Sorensen test. The thickness changes of the transversus abdominis and lumbar multifidus between resting and contraction were measured using an ultrasound scanner. Peak concentric torques of the bilateral hip extensors, hip abductors, and knee extensors were measured using an isokinetic dynamometer at 60°/s. The average values for both sides were used for statistical analysis. When averaged across sexes, peak knee extensor torque was 12.2% lower in the LBP group compared to the healthy group (mean difference, 0.29 Nm/kg; 95% confidence interval: 0.06, 0.53; P = .016). Male runners with chronic LBP exhibited smaller lumbar multifidus thickness changes compared to healthy male runners (mean difference, 0.13 cm; 95% confidence interval: 0.01, 0.25; P = .033). No other group differences were observed. Runners with chronic LBP exhibited diminished knee extensor strength compared to healthy runners. Male runners with chronic LBP demonstrated additional deficits in lumbar multifidus activation.
Rebutini, Vanessa Z; Pereira, Gleber; Bohrer, Roberta C D; Ugrinowitsch, Carlos; Rodacki, André L F
2016-09-01
Rebutini, VZ, Pereira, G, Bohrer, RCD, Ugrinowitsch, C, and Rodacki, ALF. Plyometric long jump training with progressive loading improves kinetic and kinematic swimming start parameters. J Strength Cond Res 30(9): 2392-2398, 2016-This study was aimed to determine the effects of a plyometric long jump training program on torque around the lower limb joints and kinetic and kinematics parameters during the swimming jump start. Ten swimmers performed 3 identical assessment sessions, measuring hip and knee muscle extensors during maximal voluntary isometric contraction and kinetic and kinematics parameters during the swimming jump start, at 3 instants: INI (2 weeks before the training program, control period), PRE (2 weeks after INI measurements), and POST (24-48 hours after 9 weeks of training). There were no significant changes from INI to PRE measurements. However, the peak torque and rate of torque development increased significantly from PRE to POST measurements for both hip (47 and 108%) and knee (24 and 41%) joints. There were significant improvements to the horizontal force (7%), impulse (9%), and angle of resultant force (19%). In addition, there were significant improvements to the center of mass displacement (5%), horizontal takeoff velocity (16%), horizontal velocity at water entrance (22%), and peak angle velocity for the knee (15%) and hip joints (16%). Therefore, the plyometric long jump training protocol was effective to enhance torque around the lower limb joints and to control the resultant vector direction, to increase the swimming jump start performance. These findings suggest that coaches should use long jump training instead of vertical jump training to improve swimming start performance.
Rice, David A; McNair, Peter J; Lewis, Gwyn N
2011-01-01
A consequence of knee joint osteoarthritis (OA) is an inability to fully activate the quadriceps muscles, a problem termed arthrogenic muscle inhibition (AMI). AMI leads to marked quadriceps weakness that impairs physical function and may hasten disease progression. The purpose of the present study was to determine whether γ-loop dysfunction contributes to AMI in people with knee joint OA. Fifteen subjects with knee joint OA and 15 controls with no history of knee joint pathology participated in this study. Quadriceps and hamstrings peak isometric torque (Nm) and electromyography (EMG) amplitude were collected before and after 20 minutes of 50 Hz vibration applied to the infrapatellar tendon. Between-group differences in pre-vibration torque were analysed using a one-way analysis of covariance, with age, gender and body mass (kg) as the covariates. If the γ-loop is intact, vibration should decrease torque and EMG levels in the target muscle; if dysfunctional, then torque and EMG levels should not change following vibration. One-sample t tests were thus undertaken to analyse whether percentage changes in torque and EMG differed from zero after vibration in each group. In addition, analyses of covariance were utilised to analyse between-group differences in the percentage changes in torque and EMG following vibration. Pre-vibration quadriceps torque was significantly lower in the OA group compared with the control group (P = 0.005). Following tendon vibration, quadriceps torque (P < 0.001) and EMG amplitude (P ≤0.001) decreased significantly in the control group but did not change in the OA group (all P > 0.299). Hamstrings torque and EMG amplitude were unchanged in both groups (all P > 0.204). The vibration-induced changes in quadriceps torque and EMG were significantly different between the OA and control groups (all P < 0.011). No between-group differences were observed for the change in hamstrings torque or EMG (all P > 0.554). γ-loop dysfunction may contribute to AMI in individuals with knee joint OA, partially explaining the marked quadriceps weakness and atrophy that is often observed in this population.
2011-01-01
Introduction A consequence of knee joint osteoarthritis (OA) is an inability to fully activate the quadriceps muscles, a problem termed arthrogenic muscle inhibition (AMI). AMI leads to marked quadriceps weakness that impairs physical function and may hasten disease progression. The purpose of the present study was to determine whether γ-loop dysfunction contributes to AMI in people with knee joint OA. Methods Fifteen subjects with knee joint OA and 15 controls with no history of knee joint pathology participated in this study. Quadriceps and hamstrings peak isometric torque (Nm) and electromyography (EMG) amplitude were collected before and after 20 minutes of 50 Hz vibration applied to the infrapatellar tendon. Between-group differences in pre-vibration torque were analysed using a one-way analysis of covariance, with age, gender and body mass (kg) as the covariates. If the γ-loop is intact, vibration should decrease torque and EMG levels in the target muscle; if dysfunctional, then torque and EMG levels should not change following vibration. One-sample t tests were thus undertaken to analyse whether percentage changes in torque and EMG differed from zero after vibration in each group. In addition, analyses of covariance were utilised to analyse between-group differences in the percentage changes in torque and EMG following vibration. Results Pre-vibration quadriceps torque was significantly lower in the OA group compared with the control group (P = 0.005). Following tendon vibration, quadriceps torque (P < 0.001) and EMG amplitude (P ≤0.001) decreased significantly in the control group but did not change in the OA group (all P > 0.299). Hamstrings torque and EMG amplitude were unchanged in both groups (all P > 0.204). The vibration-induced changes in quadriceps torque and EMG were significantly different between the OA and control groups (all P < 0.011). No between-group differences were observed for the change in hamstrings torque or EMG (all P > 0.554). Conclusions γ-loop dysfunction may contribute to AMI in individuals with knee joint OA, partially explaining the marked quadriceps weakness and atrophy that is often observed in this population. PMID:21933392
Akınoğlu, Bihter; Kocahan, Tuğba
2017-02-01
The objective of this study was to reveal characteristics of muscle strength of upper extremities of wheelchair (WC) basketball players and to ensure more-specific training program preparation. Isokinetic muscle strength of 12 WC basketball players were assessed by ISOMED 2000 device. The assessment protocol was evaluated at 60°/sec velocity with 5 times repeated force and at 240°/sec with 15 times repeated force. This protocol was carried out individually for shoulder flexion-extension and wrist flexion-extension movements at the right and left extremities. The flexion/extension ratio was determined to be outside of the ratios accepted as normal for primarily shoulder joint and for wrist joint. The extension movement was stronger than flexion movement in the shoulders at both velocities and the flexion movement was stronger than ex-tension movement in the wrist. The repeat times where the peak torque occurred were 2-3 repeats at 60°/sec velocity during flexion and extension movements for the wrist and shoulders, and the peak torque occurred at an average of 5-6 repeats in the shoulders at 240°/sec velocity and it occurred at 3-4 repeats in the wrist. The angles where the peak torque of the shoulder flexion and extension occurred varied between 80°-115° at both velocities, and it varied between 5°-30° angles for the wrist. As this study revealed, determination of muscle strength characteristics of WC athletes and especially using objective isokinetic devices will guide the planning of the appropriate training and exercise programs and preventing sports injuries in long term.
Su, Hsuan; Chang, Nai-Jen; Wu, Wen-Lan; Guo, Lan-Yuen; Chu, I-Hua
2017-11-01
Foam rolling has been proposed to improve muscle function, performance, and joint range of motion (ROM). However, whether a foam rolling protocol can be adopted as a warm-up to improve flexibility and muscle strength is unclear. To examine and compare the acute effects of foam rolling, static stretching, and dynamic stretching used as part of a warm-up on flexibility and muscle strength of knee flexion and extension. Crossover study. University research laboratory. 15 male and 15 female college students (age 21.43 ± 1.48 y, weight 65.13 ± 12.29 kg, height 166.90 ± 6.99 cm). Isokinetic peak torque was measured during knee extension and flexion at an angular velocity of 60°/second. Flexibility of the quadriceps was assessed by the modified Thomas test, while flexibility of the hamstrings was assessed using the sit-and-reach test. The 3 interventions were performed by all participants in random order on 3 days separated by 48-72 hours. The flexibility test scores improved significantly more after foam rolling as compared with static and dynamic stretching. With regard to muscle strength, only knee extension peak torque (pre vs. postintervention) improved significantly after the dynamic stretching and foam rolling, but not after static stretching. Knee flexion peak torque remained unchanged. Foam rolling is more effective than static and dynamic stretching in acutely increasing flexibility of the quadriceps and hamstrings without hampering muscle strength, and may be recommended as part of a warm-up in healthy young adults.
A rationale method for evaluating unscrewing torque values of prosthetic screws in dental implants
SALIBA, Felipe Miguel; CARDOSO, Mayra; TORRES, Marcelo Ferreira; TEIXEIRA, Alexandre Carvalho; LOURENÇO, Eduardo José Veras; TELLES, Daniel de Moraes
2011-01-01
Objectives Previous studies that evaluated the torque needed for removing dental implant screws have not considered the manner of transfer of the occlusal loads in clinical settings. Instead, the torque used for removal was applied directly to the screw, and most of them omitted the possibility that the hexagon could limit the action of the occlusal load in the loosening of the screws. The present study proposes a method for evaluating the screw removal torque in an anti-rotational device independent way, creating an unscrewing load transfer to the entire assembly, not only to the screw. Material and methods Twenty hexagonal abutments without the hexagon in their bases were fixed with a screw to 20 dental implants. They were divided into two groups: Group 1 used titanium screws and Group 2 used titanium screws covered with a solid lubricant. A torque of 32 Ncm was applied to the screw and then a custom-made wrench was used for rotating the abutment counterclockwise, to loosen the screw. A digital torque meter recorded the torque required to loosen the abutment. Results There was a significant difference between the means of Group 1 (38.62±6.43 Ncm) and Group 2 (48.47±5.04 Ncm), with p=0.001. Conclusion This methodology was effective in comparing unscrewing torque values of the implant-abutment junction even with a limited sample size. It confirmed a previously shown significant difference between two types of screws. PMID:21437472
77 FR 12450 - Airworthiness Directives; BRP-Powertrain GmbH & Co KG Rotax Reciprocating Engines
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-01
... have been tightened to the correct torque value, i.e. not in accordance with the specification. This... AD requires performing a one-time inspection of the oil system for leaks and a torque check of the... performing a one-time inspection of the oil system for leaks and a torque check of the oil pump attachment...
76 FR 9513 - Airworthiness Directives; BURKHART GROB LUFT-UND Model G 103 C Twin III SL Gliders
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-18
... plate) and tighten it, applying the torque following page 6.12 of the G 103 C TWIN III SL Maintenance...: The torque values and tolerances of the upper pulley wheel grooved nut have been standardized in the..., before further flight, readjust the torque of the upper pulley wheel grooved nut using the updated...
Displaying Force and Torque of A Manipulator
NASA Technical Reports Server (NTRS)
Bejczy, A. K.; Dotson, R. S.; Primus, H. C.
1984-01-01
Display combines bar charts, vector diagrams, and numerical values to inform operator of forces and torques exerted by end effector of manipulator. On voice or keyboard command, eight-channel strip-chart recorder traces force and torque components and claw position of raw measurements from eight strain gage sensors in end effector. Especially helpful when operator's view of end effector is obscured.
Evaluation of screw loosening on new abutment screws and after successive tightening.
Barbosa, Gustavo Seabra; Silva-Neto, João Paulo da; Simamoto-Júnior, Paulo Cezar; Neves, Flávio Domingues das; Mattos, Maria da Gloria Chiarello de; Ribeiro, Ricardo Faria
2011-01-01
This study evaluated the loss of the torque applied after use of new screws and after successive tightening. Four infrastructures (IE), using UCLA castable abutment type, were cast in cobalt-chromium alloy and new abutment screws (G1) were used in a first moment. Subsequently, the same abutment screws were used a second time (G2) and more than two times (G3). The values of the torques applied and detorques were measured with a digital torque wrench to obtain the values of initial tightening loss (%). Data were analyzed by ANOVA and Tukey's test (?=0.05). Significant differences were observed between the G1 (50.71% ± 11.36) and G2 (24.01% ± 3.33) (p=0.000) and between G1 (50.71% ± 11.36) and G3 (25.60% ± 4.64) (p=0.000). There was no significant difference between G2 and G3 (p=0.774). Within the limitations of the study, it may be concluded that the percentage of the initial torque loss is lower when screws that already suffered the application of an initial torque were used, remaining stable after application of successive torques.
Hagen, Marco; Asholt, Johannes; Lemke, Martin; Lahner, Matthias
2016-05-18
It is currently unclear how participation in different sports affects the angle-specific subtalar pronator and supinator muscle strength and pronator-to-supinator strength ratio (PSR). Based on the hypothesis that both differences sport-related patterns of play and foot-ground interaction may lead to sport-specific muscle adaptations, this study compared the angle specific pronator and supinator strength capacity of handball and soccer players. Eighteen healthy male handball and 19 soccer players performed maximum isometric voluntary isometric contractions using a custom-made testing apparatus. Peak pronator (PPT) and supinator torques (PST), pronator and supinator strength curves (normalised to the peak torque across all joint angles) and PSR were measured in five anatomical joint angles across the active subtalar range of motion (ROM). All analysed parameters were dependent on the subtalar joint angle. The ANOVA revealed significant `joint angle' × `group' interactions on PPT, pronator strength curves and PSR. No group differences were found for active subtalar ROM. In previously uninjured handball and soccer athletes, there were intrinsic differences in angle-specific subtalar pronator muscle strength. The lower PSR, which was found in the most supinated angle, can be seen as a risk factor for sustaining an ankle sprain.
Sprint Acceleration Mechanics: The Major Role of Hamstrings in Horizontal Force Production
Morin, Jean-Benoît; Gimenez, Philippe; Edouard, Pascal; Arnal, Pierrick; Jiménez-Reyes, Pedro; Samozino, Pierre; Brughelli, Matt; Mendiguchia, Jurdan
2015-01-01
Recent literature supports the importance of horizontal ground reaction force (GRF) production for sprint acceleration performance. Modeling and clinical studies have shown that the hip extensors are very likely contributors to sprint acceleration performance. We experimentally tested the role of the hip extensors in horizontal GRF production during short, maximal, treadmill sprint accelerations. Torque capabilities of the knee and hip extensors and flexors were assessed using an isokinetic dynamometer in 14 males familiar with sprint running. Then, during 6-s sprints on an instrumented motorized treadmill, horizontal and vertical GRF were synchronized with electromyographic (EMG) activity of the vastus lateralis, rectus femoris, biceps femoris, and gluteus maximus averaged over the first half of support, entire support, entire swing and end-of-swing phases. No significant correlations were found between isokinetic or EMG variables and horizontal GRF. Multiple linear regression analysis showed a significant relationship (P = 0.024) between horizontal GRF and the combination of biceps femoris EMG activity during the end of the swing and the knee flexors eccentric peak torque. In conclusion, subjects who produced the greatest amount of horizontal force were both able to highly activate their hamstring muscles just before ground contact and present high eccentric hamstring peak torque capability. PMID:26733889
Promoting balance and strength in the middle-aged workforce.
Granacher, U; Wick, C; Rueck, N; Esposito, C; Roth, R; Zahner, L
2011-01-01
The prevalence of sustaining fall-related injuries is high in the middle-aged workforce. Deficits in postural control/muscle strength represent important fall-risk factors. The objective of this study was to examine the impact of balance and strength training followed by detraining on postural control and muscle strength in the workforce. Thirty-two adults with sedentary office work participated in this study and were assigned to an intervention (age 56.0 ± 3.7 yrs) or a control group (age 55.5 ± 3.4 yrs). The intervention group participated in 8 weeks of balance and strength training conducted at the worksite, followed by 8 weeks of detraining. Tests included the measurement of (a) total centre of pressure (COP) displacements during one-legged standing, (b) gait velocity and stride-to-stride variability, (c) peak isometric/isokinetic torque and rate of torque development (RTD) of the plantar flexors, and (d) jumping height. After training, significant improvements in COP displacements, gait velocity, peak isometric/isokinetic torque, RTD, and jumping height were observed. During detraining, muscle strength deteriorated, whereas postural control improved. This fall-preventive training program conducted at the worksite proved to be feasible and effective. It is suggested that this training program should be permanently conducted to maintain/improve muscle strength. © Georg Thieme Verlag KG Stuttgart · New York.
EMG normalization to study muscle activation in cycling.
Rouffet, David M; Hautier, Christophe A
2008-10-01
The value of electromyography (EMG) is sensitive to many physiological and non-physiological factors. The purpose of the present study was to determine if the torque-velocity test (T-V) can be used to normalize EMG signals into a framework of biological significance. Peak EMG amplitude of gluteus maximus (GMAX), vastus lateralis (VL), rectus femoris (RF), biceps femoris long head (BF), gastrocnemius medialis (GAS) and soleus (SOL) was calculated for nine subjects during isometric maximal voluntary contractions (IMVC) and torque-velocity bicycling tests (T-V). Then, the reference EMG signals obtained from IMVC and T-V bicycling tests were used to normalize the amplitude of the EMG signals collected for 15 different submaximal pedaling conditions. The results of this study showed that the repeatability of the measurements between IMVC (from 10% to 23%) and T-V (from 8% to 20%) was comparable. The amplitude of the peak EMG of VL was 99+/-43% higher (p<0.001) when measured during T-V. Moreover, the inter-individual variability of the EMG patterns calculated for submaximal cycling exercises differed significantly when using T-V bicycling normalization method (GMAX: 0.33+/-0.16 vs. 1.09+/-0.04, VL: 0.07+/-0.02 vs. 0.64+/-0.14, SOL: 0.07+/-0.03 vs. 1.00+/-0.07, RF: 1.21+/-0.20 vs. 0.92+/-0.13, BF: 1.47+/-0.47 vs. 0.84+/-0.11). It was concluded that T-V bicycling test offers the advantage to be less time and energy-consuming and to be as repeatable as IMVC tests to measure peak EMG amplitude. Furthermore, this normalization method avoids the impact of non-physiological factors on the amplitude of the EMG signals so that it allows quantifying better the activation level of lower limb muscles and the variability of the EMG patterns during submaximal bicycling exercises.
NASA Astrophysics Data System (ADS)
Fontchastagner, Julien; Lubin, Thierry; Mezani, Smaïl; Takorabet, Noureddine
2018-03-01
This paper presents a design optimization of an axial-flux eddy-current magnetic coupling. The design procedure is based on a torque formula derived from a 3D analytical model and a population algorithm method. The main objective of this paper is to determine the best design in terms of magnets volume in order to transmit a torque between two movers, while ensuring a low slip speed and a good efficiency. The torque formula is very accurate and computationally efficient, and is valid for any slip speed values. Nevertheless, in order to solve more realistic problems, and then, take into account the thermal effects on the torque value, a thermal model based on convection heat transfer coefficients is also established and used in the design optimization procedure. Results show the effectiveness of the proposed methodology.
Bayani, Shahin; Masoomi, Fatemeh; Aghaabbasi, Sharereh; Farsinejad, Alireza
2016-01-01
The purpose of this study was to evaluate the effect of platelet-released growth factor (PRGF) and immediate orthodontic forces on the removal torque of miniscrews. This study was conducted on three male dogs aged 6 to 8 months with a body weight of 17.6 to 18.4 kg. Sixty miniscrews were inserted in the posterior aspect of the femur. There were four groups, including loaded miniscrews with application of PRGF, unloaded miniscrews without application of PRGF, unloaded miniscrews with PRGF, and loaded miniscrews without PRGF. Twenty miniscrews were inserted in the femoral bone of one foot of each dog, including all the aforementioned subgroups. After 12 weeks, the miniscrews were removed by a removal torque tester device and measured in newton centimeters. The mean removal torque values in four groups of immediately loaded screws with PRGF, unloaded screws with PRGF, immediately loaded screws without PRGF, and unloaded screws without PRGF were 19.68, 21.74, 13.65, and 15.46 Ncm, respectively. It was shown that the mean removal torque value for the group with PRGF was significantly higher than that in the other groups (P = .0001). Although there was a tendency toward a decrease in removal torque value with immediate loading, it was not statistically significant (P = .21). According to the results of this study, applying PRGF with miniscrews increased their stability, but the delivery of immediate force on miniscrews had no effect on the miniscrews' stability.
Lee, J H; Lee, J-H; Park, J W; Shin, Y H
2012-01-01
In patients with osteoporosis there is always a strong possibility that pedicle screws will loosen. This makes it difficult to select the appropriate osteoporotic patient for a spinal fusion. The purpose of this study was to determine the correlation between bone mineral density (BMD) and the magnitude of torque required to insert a pedicle screw. To accomplish this, 181 patients with degenerative disease of the lumbar spine were studied prospectively. Each underwent dual-energy x-ray absorptiometry (DEXA) and intra-operative measurement of the torque required to insert each pedicle screw. The levels of torque generated in patients with osteoporosis and osteopenia were significantly lower than those achieved in normal patients. Positive correlations were observed between BMD and T-value at the instrumented lumbar vertebrae, mean BMD and mean T-value of the lumbar vertebrae, and mean BMD and mean T-value of the proximal femur. The predictive torque (Nm) generated during pedicle screw insertion was [-0.127 + 1.62 × (BMD at the corresponding lumbar vertebrae)], as measured by linear regression analysis. The positive correlation between BMD and the maximum torque required to insert a pedicle screw suggests that pre-operative assessment of BMD may be useful in determining the ultimate strength of fixation of a device, as well as the number of levels that need to be fixed with pedicle screws in patients who are suspected of having osteoporosis.
Kim, Ki-Seong; Lim, Young-Jun; Kim, Myung-Joo; Kwon, Ho-Beom; Yang, Jae-Ho; Lee, Jai-Bong; Yim, Soon-Ho
2011-08-01
Settling (embedment relaxation), which is the main cause for screw loosening, is developed by microroughness between implant and abutment metal surface. The objective of this study was to evaluate and compare the relationship between the level of applied torque and the settling of abutments into implants in external and internal implant-abutment connection. Five different implant-abutment connections were used (Ext, External butt joint + two-piece abutment; Int-H2, Internal hexagon + two-piece abutment; Int-H1, Internal hexagon + one-piece abutment; Int-O2, Internal octagon + two-piece abutment; Int-O1, Internal octagon + one-piece abutment). All abutments of each group were assembled and tightened with corresponding implants by a digital torque gauge. The total lengths of implant-abutment samples were measured at each torque (5, 10, 30 N cm and repeated 30 N cm with 10-min interval) by an electronic digital micrometer. The settling values were calculated by changes between the total lengths of implant-abutment samples. All groups developed settling with repeated tightening. The Int-H2 group showed markedly higher settling for all instances of tightening torque and the Ext group was the lowest. Statistically significant differences were found in settling values between the groups and statistically significant increases were observed within each group at different tightening torques (P<0.05). After the second tightening of 30 N cm, repeated tightening showed almost constant settling values. Results from the present study suggested that to minimize the settling effect, abutment screws should be retightened at least twice at 30 N cm torque at a 10-min interval in all laboratory and clinical procedures. © 2010 John Wiley & Sons A/S.
NASA Astrophysics Data System (ADS)
Ou, Yongxi; Ralph, D. C.; Buhrman, R. A.
2018-03-01
Robust spin Hall effects (SHE) have recently been observed in nonmagnetic heavy metal systems with strong spin-orbit interactions. These SHE are either attributed to an intrinsic band-structure effect or to extrinsic spin-dependent scattering from impurities, namely, side jump or skew scattering. Here we report on an extraordinarily strong spin Hall effect, attributable to spin fluctuations, in ferromagnetic FexPt1 -x alloys near their Curie point, tunable with x . This results in a dampinglike spin-orbit torque being exerted on an adjacent ferromagnetic layer that is strongly temperature dependent in this transition region, with a peak value that indicates a lower bound 0.34 ±0.02 for the peak spin Hall ratio within the FePt. We also observe a pronounced peak in the effective spin-mixing conductance of the FM /FePt interface, and determine the spin diffusion length in these FexPt1 -x alloys. These results establish new opportunities for fundamental studies of spin dynamics and transport in ferromagnetic systems with strong spin fluctuations, and a new pathway for efficiently generating strong spin currents for applications.
Friction losses in a lubricated thrust-loaded cageless angular-contract bearing
NASA Technical Reports Server (NTRS)
Townsend, D. P.; Allen, C. W.; Zaretsky, E. V.
1973-01-01
The NASA spinning torque apparatus was modified to measure the spinning torque on a cageless ball thrust bearing. Friction torque was measured for thrust loads varying from 44.5 to 403 newtons (10 to 90 lb) at speeds of 1000, 2000, and 3000 rpm. Tests were conducted with di-2-ethylhexyl sebacate and a synthetic paraffinic oil. These tests were run with either oil jet lubrication or with a thin surface film of lubricant only. An analytical model which included rolling resistance was developed and extended from previous models for spinning torque and lubricant rheology. The model was extended by the inclusion of rolling resistance. The computed values were in fair agreement with the experimental results and confirmed previous hypotheses that a thin lubricant film gives minimum bearing torque and an oil jet flow of a viscous lubricant will result in considerable rolling torque in addition to the torque due to ball spin.
EFFECT OF PILOT HOLE TAPPING ON PULLOUT STRENGTH AND INSERTION TORQUE OF DUAL CORE PEDICLE SCREWS.
Rosa, Rodrigo César; Silva, Patrícia; Falcai, Maurício José; Shimano, Antônio Carlos; Defino, Helton Luiz Aparecido
2010-01-01
To evaluate the influence of pilot hole tapping on pullout resistance and insertion torque of pedicle screws with a conical core. Mechanical tests using a universal testing machine were performed on pedicle screws with a conical core that were inserted into pedicles in the fifth lumbar vertebra of calves. The insertion torque was measured using a torque meter with a capacity of 10 Nm, which was considered to be the highest torque value. The pilot holes were prepared using a probe of external diameter 3.8 mm and tapping of the same dimensions and thread characteristics as the screw. Decreased insertion torque and pullout resistance were observed in the group with prior tapping of the pilot hole. Pilot hole tapping reduced the insertion torque and pullout resistance of pedicle screws with a conical core that had been inserted into the pedicle of the fifth lumbar vertebra of calves.
Torque Control of a Rehabilitation Teaching Robot Using Magneto-Rheological Fluid Clutches
NASA Astrophysics Data System (ADS)
Hakogi, Hokuto; Ohaba, Motoyoshi; Kuramochi, Naimu; Yano, Hidenori
A new robot that makes use of MR-fluid clutches for simulating torque is proposed to provide an appropriate device for training physical therapy students in knee-joint rehabilitation. The feeling of torque provided by the robot is expected to correspond to the torque performance obtained by physical therapy experts in a clinical setting. The torque required for knee-joint rehabilitation, which is a function of the rotational angle and the rotational angular velocity of a knee movement, is modeled using a mechanical system composed of typical spring-mass-damper elements. The robot consists of two MR-fluid clutches, two induction motors, and a feedback control system. In the torque experiments, output torque is controlled using the spring and damper coefficients separately. The values of these coefficients are determined experimentally. The experimental results show that the robot would be suitable for training physical therapy students to experience similar torque feelings as needed in a clinical situation.
Influence of the implant-abutment connection design and diameter on the screw joint stability.
Shin, Hyon-Mo; Huh, Jung-Bo; Yun, Mi-Jeong; Jeon, Young-Chan; Chang, Brian Myung; Jeong, Chang-Mo
2014-04-01
This study was conducted to evaluate the influence of the implant-abutment connection design and diameter on the screw joint stability. Regular and wide-diameter implant systems with three different joint connection designs: an external butt joint, a one-stage internal cone, and a two-stage internal cone were divided into seven groups (n=5, in each group). The initial removal torque values of the abutment screw were measured with a digital torque gauge. The postload removal torque values were measured after 100,000 cycles of a 150 N and a 10 Hz cyclic load had been applied. Subsequently, the rates of the initial and postload removal torque losses were calculated to evaluate the effect of the joint connection design and diameter on the screw joint stability. Each group was compared using Kruskal-Wallis test and Mann-Whitney U test as post-hoc test (α=0.05). THE POSTLOAD REMOVAL TORQUE VALUE WAS HIGH IN THE FOLLOWING ORDER WITH REGARD TO MAGNITUDE: two-stage internal cone, one-stage internal cone, and external butt joint systems. In the regular-diameter group, the external butt joint and one-stage internal cone systems showed lower postload removal torque loss rates than the two-stage internal cone system. In the wide-diameter group, the external butt joint system showed a lower loss rate than the one-stage internal cone and two-stage internal cone systems. In the two-stage internal cone system, the wide-diameter group showed a significantly lower loss rate than the regular-diameter group (P<.05). The results of this study showed that the external butt joint was more advantageous than the internal cone in terms of the postload removal torque loss. For the difference in the implant diameter, a wide diameter was more advantageous in terms of the torque loss rate.
Influence of the implant-abutment connection design and diameter on the screw joint stability
Shin, Hyon-Mo; Huh, Jung-Bo; Yun, Mi-Jeong; Jeon, Young-Chan; Chang, Brian Myung
2014-01-01
PURPOSE This study was conducted to evaluate the influence of the implant-abutment connection design and diameter on the screw joint stability. MATERIALS AND METHODS Regular and wide-diameter implant systems with three different joint connection designs: an external butt joint, a one-stage internal cone, and a two-stage internal cone were divided into seven groups (n=5, in each group). The initial removal torque values of the abutment screw were measured with a digital torque gauge. The postload removal torque values were measured after 100,000 cycles of a 150 N and a 10 Hz cyclic load had been applied. Subsequently, the rates of the initial and postload removal torque losses were calculated to evaluate the effect of the joint connection design and diameter on the screw joint stability. Each group was compared using Kruskal-Wallis test and Mann-Whitney U test as post-hoc test (α=0.05). RESULTS The postload removal torque value was high in the following order with regard to magnitude: two-stage internal cone, one-stage internal cone, and external butt joint systems. In the regular-diameter group, the external butt joint and one-stage internal cone systems showed lower postload removal torque loss rates than the two-stage internal cone system. In the wide-diameter group, the external butt joint system showed a lower loss rate than the one-stage internal cone and two-stage internal cone systems. In the two-stage internal cone system, the wide-diameter group showed a significantly lower loss rate than the regular-diameter group (P<.05). CONCLUSION The results of this study showed that the external butt joint was more advantageous than the internal cone in terms of the postload removal torque loss. For the difference in the implant diameter, a wide diameter was more advantageous in terms of the torque loss rate. PMID:24843398
Wiesinger, Hans-Peter; Wiemer, Nicolas; Kösters, Alexander; Müller, Erich
2016-01-01
Abstract The present study was conducted to assess test-retest reproducibility of explosive strength measurements during single-joint isometric knee extension using the IsoMed 2000 dynamometer. Thirty-one physically active male subjects (mean age: 23.7 years) were measured on two occasions separated by 48–72 h. The intraclass correlation coefficient (ICC 2,1) and the coefficient of variation (CV) were calculated for (i) maximum torque (MVC), (ii) the peak rate of torque development (RTDpeak) as well as for (iii) the average rate of torque development (RTD) and the impulse taken at several predefined time intervals (0–30 to 0–300 ms); thereby explosive strength variables were derived in two conceptually different versions: on the one hand from the MVC-trial (version I), on the other hand from the trial showing the RTDpeak (version II). High ICC-values (0.80–0.99) and acceptable CV-values (1.9–8.7%) could be found for MVC as well as for the RTD and the impulse taken at time intervals of ≥100 ms, regardless of whether version I or II was used. In contrast, measurements of the RTDpeak as well as the RTD and the impulse taken during the very early contraction phase (i.e. RTD/impulse0–30ms and RTD/impulse0–50ms) showed clearly weaker reproducibility results (ICC: 0.53–0.84; CV: 7.3–16.4%) and gave rise to considerable doubts as to clinical usefulness, especially when derived using version I. However, if there is a need to measure explosive strength for earlier time intervals in practice, it is, in view of stronger reproducibility results, recommended to concentrate on measures derived from version II, which is based on the RTDpeak-trial. PMID:28149337
Torquing preload in a lubricated bolt
NASA Technical Reports Server (NTRS)
Seegmiller, H. L.
1978-01-01
The tension preload obtained by torquing a 7/8 in. diam UNC high strength bolt was determined for lubricated and dry conditions. Consistent preload with a variation of + or - 3% was obtained when the bolt head area was lubricated prior to each torque application. Preload tensions nearly 70% greater than the value predicted with the commonly used formula occurred with the lubricated bolt. A reduction to 39% of the initial preload was observed during 50 torque applications without relubrication. Little evidence of wear was noted after 203 cycles of tightening.
Nesbit, Steven M.; Elzinga, Michael; Herchenroder, Catherine; Serrano, Monika
2006-01-01
This paper discusses the inertia tensors of tennis rackets and their influence on the elbow swing torques in a forehand motion, the loadings transmitted to the elbow from central and eccentric impacts, and the racket acceleration responses from central and eccentric impacts. Inertia tensors of various rackets with similar mass and mass center location were determined by an inertia pendulum and were found to vary considerably in all three orthogonal directions. Tennis swing mechanics and impact analyses were performed using a computer model comprised of a full-body model of a human, a parametric model of the racket, and an impact function. The swing mechanics analysis of a forehand motion determined that inertia values had a moderate linear effect on the pronation-supination elbow torques required to twist the racket, and a minor effect on the flexion-extension and valgus-varus torques. The impact analysis found that mass center inertia values had a considerable effect on the transmitted torques for both longitudinal and latitudinal eccentric impacts and significantly affected all elbow torque components. Racket acceleration responses to central and eccentric impacts were measured experimentally and found to be notably sensitive to impact location and mass center inertia values. Key Points Tennis biomechanics. Racket inertia tensor. Impact analysis. Full-body computer model. PMID:24260004
Probabilistic analysis of preload in the abutment screw of a dental implant complex.
Guda, Teja; Ross, Thomas A; Lang, Lisa A; Millwater, Harry R
2008-09-01
Screw loosening is a problem for a percentage of implants. A probabilistic analysis to determine the cumulative probability distribution of the preload, the probability of obtaining an optimal preload, and the probabilistic sensitivities identifying important variables is lacking. The purpose of this study was to examine the inherent variability of material properties, surface interactions, and applied torque in an implant system to determine the probability of obtaining desired preload values and to identify the significant variables that affect the preload. Using software programs, an abutment screw was subjected to a tightening torque and the preload was determined from finite element (FE) analysis. The FE model was integrated with probabilistic analysis software. Two probabilistic analysis methods (advanced mean value and Monte Carlo sampling) were applied to determine the cumulative distribution function (CDF) of preload. The coefficient of friction, elastic moduli, Poisson's ratios, and applied torque were modeled as random variables and defined by probability distributions. Separate probability distributions were determined for the coefficient of friction in well-lubricated and dry environments. The probabilistic analyses were performed and the cumulative distribution of preload was determined for each environment. A distinct difference was seen between the preload probability distributions generated in a dry environment (normal distribution, mean (SD): 347 (61.9) N) compared to a well-lubricated environment (normal distribution, mean (SD): 616 (92.2) N). The probability of obtaining a preload value within the target range was approximately 54% for the well-lubricated environment and only 0.02% for the dry environment. The preload is predominately affected by the applied torque and coefficient of friction between the screw threads and implant bore at lower and middle values of the preload CDF, and by the applied torque and the elastic modulus of the abutment screw at high values of the preload CDF. Lubrication at the threaded surfaces between the abutment screw and implant bore affects the preload developed in the implant complex. For the well-lubricated surfaces, only approximately 50% of implants will have preload values within the generally accepted range. This probability can be improved by applying a higher torque than normally recommended or a more closely controlled torque than typically achieved. It is also suggested that materials with higher elastic moduli be used in the manufacture of the abutment screw to achieve a higher preload.
Gambarini, G
2001-12-01
The main problem with the NiTi rotary instrumentation technique is instrument failure. During shaping procedures, rotary instruments might lock and/or screw into canals and, consequently, be subjected to high levels of stress. This may frequently lead to instrument separation or deformation. If a high-torque motor is used, the applied forces are usually very high and the instrument-fracture limit is often exceeded, thus increasing the risk of intracanal failure. A possible solution of this problem is to use a low-torque endodontic motor, which operates below the maximum permissible torque limit of each and every rotary instrument. During clinical instrumentation of root canals, if a torque-controlled motor is loaded right up to the instrument-specific torque, the motor stops momentarily and/or starts rotating counter-clockwise (auto-reverse function) to disengage the locked instrument. These safety mechanisms were developed to reduce the risk of instrument fracture. The author fully discusses the rationale for selecting lower torque values in everyday endodontic practice, and provides clinicians with useful information on the advantages and disadvantages of new endodontic motors with torque control.
Explosive Strength Imbalances in Professional Basketball Players
Schiltz, Marc; Lehance, Cédric; Maquet, Didier; Bury, Thierry; Crielaard, Jean-Michel; Croisier, Jean-Louis
2009-01-01
Context: Despite the high rate of lower limb injuries in basketball players, studies of the dominant-limb effect in elite athletes often neglect injury history. Objective: To determine lower limb explosive-strength asymmetries in professional basketball players compared with junior basketball players and control participants. Design: Cohort study. Setting: Academic medical institution. Patients or Other Participants: 15 professional basketball players, 10 junior basketball players, and 20 healthy men. Main Outcome Measure(s): We performed an isokinetic examination to evaluate the knee extensor (Ext) and flexor (Fl) concentric peak torque at 60°·s−1 and 240°·s−1 and (Fl only) eccentric peak torque at 30°·s−1 and 120°·s−1. Functional evaluation included countermovement jump, countermovement jump with arms, 10-m sprint, single-leg drop jump, and single-leg, 10-second continuous jumping. Variables were compared among groups using analysis of variance or a generalized linear mixed model for bilateral variables. Results: The 2 groups of basketball players demonstrated better isokinetic and functional performances than the control group did. No differences in functional or relative isokinetic variables were noted between professional and junior basketball players. Professional players with a history of knee injury failed to reach normal knee extensor strength at 60°·s−1. Knee Ext (60°·s−1) and Fl (eccentric 120°·s−1) torque values as well as 10-second continuous jumping scores were higher in those professional players without a history of knee injury than those with such a history. Compared with the group without a history of knee injury, the group with a history of knee injury maintained leg asymmetry ratios greater than 10% for almost all isokinetic variables and more than 15% for unilateral functional variables. Conclusions: The relative isokinetic and functional performances of professional basketball players were similar to those of junior players, with no dominant-side effect. A history of knee injury in the professional athlete, however, was reflected in bilateral isokinetic and functional asymmetries and should be considered in future studies of explosive strength. PMID:19180217
Vibration characteristics of OH-58A helicopter main rotor transmission
NASA Technical Reports Server (NTRS)
Lewicki, David G.; Coy, John J.
1987-01-01
Experimental vibration tests covering a range of torque and speed conditions were performed on the OH-58A helicopter main rotor transmission at the NASA Lewis Research Center. Signals from accelerometers located on the transmission housing were analyzed by using Fourier spectra, power spectral density functions, and averaging techniques. Most peaks of the Fourier spectra occurred at the spiral bevel and planetary gear mesh harmonics. The highest level of vibration occurred at the spiral bevel meshing frequency. Transmission speed and vibration measurement location had a significant effect on measured vibration; transmission torque and measurement direction had a small effect.
Bioactive ceramic coating of cancellous screws improves the osseointegration in the cancellous bone.
Lee, Jae Hyup; Nam, Hwa; Ryu, Hyun-Seung; Seo, Jun-Hyuk; Chang, Bong-Soon; Lee, Choon-Ki
2011-05-01
A number of methods for coating implants with bioactive ceramics have been reported to improve osseointegration in bone, but the effects of bioactive ceramic coatings on the osseointegration of cancellous screws are not known. Accordingly, biomechanical and histomorphometric analyses of the bone-screw interface of uncoated cancellous screws and cancellous screws coated with four different bioactive ceramics were performed. After coating titanium alloy cancellous screws with calcium pyrophosphate (CPP), CaO-SiO(2)-B(2)O(3) glass-ceramics (CSG), apatite-wollastonite 1:3 glass-ceramics (W3G), and CaO-SiO(2)-P(2)O(5)-B(2)O(3) glass-ceramics (BGS-7) using an enameling method, the coated and the uncoated screws were inserted into the proximal tibia and distal femur metaphysis of seven male mongrel dogs. The torque values of the screws were measured at the time of insertion and at removal after 8 weeks. The bone-screw contact ratio was analyzed by histomorphometry. There was no significant difference in the insertion torque between the uncoated and coated screws. The torque values of the CPP and BGS-7 groups measured at removal after 8 weeks were significantly higher than those of the uncoated group. Moreover, the values of the CPP and BGS-7 groups were significantly higher than the insertion torques. The fraction of bone-screw interface measured from the undecalcified histological slide showed that the CPP, W3G, and BGS-7 groups had significantly higher torque values in the cortical bone area than the uncoated group, and the CPP and BGS-7 groups had significantly higher torque values in the cancellous bone area than the uncoated group. In conclusion, a cancellous screw coated with CPP and BGS-7 ceramic bonds directly to cancellous bone to improve the bone-implant osseointegration. This may broaden the indications for cancellous screws by clarifying their contribution to improving osseointegration, even in the cancellous bone area.
NASA Astrophysics Data System (ADS)
Pristup, A. G.; Toporkov, D. M.
2017-10-01
The results of the investigation of the cogging torque in permanent magnet synchronous machines, which is caused by the stator slotting and the rotor eccentricity, are presented in the paper. A new design of the machine has been developed in the course of the investigation, and the value of the cogging torque in this construction is less considerably compared to other constructions. In contrast to the available methods of the cogging torque reduction, the solution suggested not only decreases the level of the cogging torque but also has negligibly small influence on characteristics of the machine with the rotor eccentricity which is typical of the mass production and long-term usage.
Current induced domain wall dynamics in the presence of spin orbit torques
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boulle, O., E-mail: Olivier.boulle@cea.fr; Buda-Prejbeanu, L. D.; Jué, E.
2014-05-07
Current induced domain wall (DW) motion in perpendicularly magnetized nanostripes in the presence of spin orbit torques is studied. We show using micromagnetic simulations that the direction of the current induced DW motion and the associated DW velocity depend on the relative values of the field like torque (FLT) and the Slonczewski like torques (SLT). The results are well explained by a collective coordinate model which is used to draw a phase diagram of the DW dynamics as a function of the FLT and the SLT. We show that a large increase in the DW velocity can be reached bymore » a proper tuning of both torques.« less
Steps in the bacterial flagellar motor.
Mora, Thierry; Yu, Howard; Sowa, Yoshiyuki; Wingreen, Ned S
2009-10-01
The bacterial flagellar motor is a highly efficient rotary machine used by many bacteria to propel themselves. It has recently been shown that at low speeds its rotation proceeds in steps. Here we propose a simple physical model, based on the storage of energy in protein springs, that accounts for this stepping behavior as a random walk in a tilted corrugated potential that combines torque and contact forces. We argue that the absolute angular position of the rotor is crucial for understanding step properties and show this hypothesis to be consistent with the available data, in particular the observation that backward steps are smaller on average than forward steps. We also predict a sublinear speed versus torque relationship for fixed load at low torque, and a peak in rotor diffusion as a function of torque. Our model provides a comprehensive framework for understanding and analyzing stepping behavior in the bacterial flagellar motor and proposes novel, testable predictions. More broadly, the storage of energy in protein springs by the flagellar motor may provide useful general insights into the design of highly efficient molecular machines.
Preload evaluation of different screws in external hexagon joint.
Assunção, Wirley Gonçalves; Delben, Juliana Aparecida; Tabata, Lucas Fernando; Barão, Valentim Adelino Ricardo; Gomes, Erica Alves; Garcia, Idelmo Rangel
2012-02-01
This study compared the maintenance of tightening torque in different retention screw types of implant-supported crowns. Twelve metallic crowns in UCLA abutments cast with cobalt-chromium alloy were attached to external hexagon osseointegrated implants with different retention screws: group A: titanium alloy retention screw; group B: gold alloy retention screw with gold coating; group C: titanium alloy retention screw with diamond-like carbon film coating; and group D: titanium alloy retention screw with aluminum titanium nitride coating. Three detorque measurements were obtained after torque insertion in each replica. Data were evaluated by analysis of variance (ANOVA), Tukey's test (P < 0.05), and t test (P < 0.05). Detorque value reduced in all groups (P < 0.05). Group A retained the highest percentage of torque in comparison with the other groups (P < 0.05). Groups B and D retained the lowest percentage of torque without statistically significant difference between them (P > 0.05). All screw types exhibited reduction in the detorque value. The titanium screw maintained the highest percentage of torque whereas the gold-coated screw and the titanium screw with aluminum titanium nitride coating retained the lowest percentage.
A torque balance measurement of anisotropy of the magnetic susceptibility in white matter.
van Gelderen, Peter; Mandelkow, Hendrik; de Zwart, Jacco A; Duyn, Jeff H
2015-11-01
Recent MRI studies have suggested that the magnetic susceptibility of white matter (WM) in the human brain is anisotropic, providing a new contrast mechanism for the visualization of fiber bundles and allowing the extraction of cellular compartment-specific information. This study provides an independent confirmation and quantification of this anisotropy. Anisotropic magnetic susceptibility results in a torque exerted on WM when placed in a uniform magnetic field, tending to align the WM fibers with the field. To quantify the effect, excised spinal cord samples were placed in a torque balance inside the magnet of a 7 T MRI system and the magnetic torque was measured as function of orientation. All tissue samples (n = 5) showed orienting effects, confirming the presence of anisotropic susceptibility. Analysis of the magnetic torque resulted in reproducible values for the WM volume anisotropy that ranged from 13.6 to 19.2 ppb. The independently determined anisotropy values confirm estimates inferred from MRI experiments and validate the use of anisotropy to extract novel information about brain fiber structure and myelination. © 2014 Wiley Periodicals, Inc.
Measurement of additional shear during sludge conditioning and dewatering.
Ormeci, Banu; Ahmad, Ayaz
2009-07-01
Optimum polymer dose is influenced both by the polymer demand of the sludge and the shear applied during conditioning. Sludge exposed to additional shear following conditioning will experience a decrease in cake solids concentration for the same polymer dose. Therefore, it is necessary to measure or quantify the additional shear in order to optimize the conditioning and dewatering. There is currently no direct or indirect method to achieve this. The main objective of this study was to develop a method based on torque rheology to measure the amount of shear that a sludge network experiences during conditioning and dewatering. Anaerobically digested sludge samples were exposed to increasing levels of mixing intensities and times, and rheological characteristics of samples were measured using a torque rheometer. Several rheological parameters were evaluated including the peak torque and totalized torque (area under the rheograms). The results of this study show that at the optimum polymer dose, a linear relationship exists between the applied shear and the area under the rheograms, and this relationship can be used to estimate an unknown amount of shear that the sludge was exposed to. The method is useful as a research tool to study the effect of shear on dewatering but also as an optimization tool in a dewatering automation system based on torque rheology.
A thin membrane artificial muscle rotary motor
NASA Astrophysics Data System (ADS)
Anderson, Iain A.; Hale, Thom; Gisby, Todd; Inamura, Tokushu; McKay, Thomas; O'Brien, Benjamin; Walbran, Scott; Calius, Emilio P.
2010-01-01
Desirable rotary motor attributes for robotics include the ability to develop high torque in a low mass body and to generate peak power at low rotational speeds. Electro-active polymer artificial muscles offer promise as actuator elements for robotic motors. A promising artificial muscle technology for use as a driving mechanism for rotary motion is the dielectric elastomer actuator (DEA). We present a membrane DEA motor in which phased actuation of electroded sectors of the motor membrane impart orbital motion to a central drive that turns a rotor. The motor is inherently scalable, flexible, flat, silent in operation, amenable to deposition-based manufacturing approaches, and uses relatively inexpensive materials. As a membrane it can also form part of the skin of a robot. We have investigated the torque and power of stacked membrane layers. Specific power and torque ratios when calculated using active membrane mass only were 20.8 W/kg and 4.1 Nm/kg, respectively. These numbers compare favorably with a commercially available stepper motor. Multi-membrane fabrication substantially boosts torque and power and increases the active mass of membrane relative to supporting framework. Through finite element modeling, we show the mechanisms governing the maximum torque the device can generate and how the motor can be improved.
Wang, Tong-Mei; Lee, Ming-Shu; Wang, Juo-Song; Lin, Li-Deh
2015-01-01
This study investigated the effect of implant design and bone quality on insertion torque (IT), implant stability quotient (ISQ), and insertion energy (IE) by monitoring the continuous change in IT and ISQ while implants were inserted in artificial bone blocks that simulate bone of poor or poor-to-medium quality. Polyurethane foam blocks (Sawbones) of 0.16 g/cm³ and 0.32 g/cm³ were respectively used to simulate low density and low- to medium-density cancellous bone. In addition, some test blocks were laminated with a 1-mm 0.80 g/cm³ polyurethane layer to simulate cancellous bone with a thin cortical layer. Four different implants (Nobel Biocare Mk III-3.75, Mk III-4.0, Mk IV-4.0, and NobelActive-4.3) were placed into the different test blocks in accordance with the manufacturer's instructions. The IT and ISQ were recorded at every 0.5-mm of inserted length during implant insertion, and IE was calculated from the torque curve. The peak IT (PIT), final IT (FIT), IE, and final ISQ values were statistically analyzed. All implants showed increasing ISQ values when the implant was inserted more deeply. In contrast to the ISQ, implants with different designs showed dissimilar IT curve patterns during the insertion. All implants showed a significant increase in the PIT, FIT, IE, and ISQ when the test-block density increased or when the 1-mm laminated layer was present. Tapered implants showed FIT or PIT values of more than 40 Ncm for all of the laminated test blocks and for the nonlaminated test blocks of low to medium density. Parallel-wall implants did not exhibit PIT or FIT values of more than 40 Ncm for all of the test blocks. NobelActive-4.3 showed a significantly higher FIT, but a significantly lower IE, than Mk IV-4.0. While the existence of cortical bone or implant designs significantly affects the dynamic IT profiles during implant insertion, it does not affect the ISQ to a similar extent. Certain implant designs are more suitable than others if high IT is required in bone of poor quality. The manner in which IT, IE, and ISQ represent the implant primary stability requires further study.
NASA Technical Reports Server (NTRS)
Hart, J. F.
1973-01-01
MSFC-STD-486, Threaded Fasteners, Torque Limits For, is a relatively new standard that has not had much user experience. This test was run to provide such experience and verify the values in MSFC-STD-486. This was accomplished by plotting torque-tension curves on aluminum and alloy steel aircraft quality bolts and nuts through 1/2 inch in diameter.
Reduction of Risk for Low Back Injury in Theater of Operations
2015-06-01
Assessed for eligibility (n = 698) 14 Figure 4. Predicted (from regression) isometric lumbar extension strength ( torque ) mean values (adjusted by...resistance exercise to the lumbar extensors in the ranges required for strength development, torque production from the gluteals and hamstrings must be...the small lumbar muscles play only a minor role in trunk extension torque production.17 Thus, they are considered to be the weak link in trunk
Chowdhary, Ramesh; Jimbo, Ryo; Thomsen, Christian; Carlsson, Lennart; Wennerberg, Ann
2013-03-01
To investigate the combined effect of macro and pitch shortened threads on primary and secondary stability during healing, but before dynamic loading. Two sets of turned implants with different macro geometry were prepared. The test group possessed pitch shortened threads in between the large threads and the control group did not have thread alterations. The two implant groups were placed in both femur and tibiae of 10 lop-eared rabbits, and at the time of implant insertion, insertion torques were recorded. After 4 weeks, all implants were subjected to removal torque tests. The insertion torque values for the control and test groups for the tibia were 15.7 and 20.6 Ncm, respectively, and for the femur, 11.8, and 12.8 Ncm respectively. The removal torque values for the control and test groups in the tibia were 7.9 and 9.1 Ncm, respectively, and for the femur, 7.9 and 7.7 Ncm respectively. There was no statistically significant difference between the control and test groups. Under limited dynamic load, the addition of pitch shortened threads did not significantly improve either the primary or the secondary stability of the implants in bone. © 2011 John Wiley & Sons A/S.
Muscle activation and the isokinetic torque-velocity relationship of the human triceps surae.
Harridge, S D; White, M J
1993-01-01
The influence of muscle activation and the time allowed for torque generation on the angle-specific torque-velocity relationship of the triceps surae was studied during plantar flexion using supramaximal electrical stimulation and a release technique on six male subjects [mean (SD) age 25 (4) years]. Torque-velocity data were obtained under different levels of constant muscle activation by varying the stimulus frequency and the time allowed for isometric torque generation prior to release and isokinetic shortening. To eliminate the effects of the frequency response on absolute torque the isokinetic data were normalized to the maximum isometric torque values at 0.44 rad. There were no significant differences in the normalized torques generated at any angular velocity using stimulus frequencies of 20, 50 or 80 Hz. When the muscle was stimulated at 50 Hz the torques obtained after a 400 ms and 1 s pre-release isometric contraction did not differ significantly. However, with no pre-release contraction significantly less torque was generated at all angular velocities beyond 1.05 rad.s-1 when compared with either the 200, 400 ms or 1 s condition. With a 200 ms pre-release contraction significantly less torque was generated at angular velocities beyond 1.05 rad.s-1 when compared with the 400 ms or 1 s conditions. It would seem that the major factor governing the shape of the torque-velocity curve at a constant level of muscle activation is the time allowed for torque generation.
Chan, Bill K S; Ng, Shamay S M; Ng, Gabriel Y F
2015-01-01
Impaired trunk motor control is common after stroke. Combining transcutaneous electrical nerve stimulation (TENS) with task-related trunk training (TRTT) has been shown to enhance the recovery of lower limb motor function. This study investigated whether combining TENS with TRTT would enhance trunk control after stroke. Methods. Thirty-seven subjects with stroke were recruited into a randomized controlled clinical trial. Subjects were randomly assigned to any one of the three 6-week home-based training groups: (1) TENS + TRTT, (2) placebo TENS + TRTT, or (3) control without active training. The outcome measures included isometric peak trunk flexion torque and extension torque; forward seated and lateral seated reaching distance to the affected and unaffected side; and Trunk Impairment Scale (TIS) scores. All outcome measures were assessed at baseline, after 3 and 6 weeks of training, and 4 weeks after training ended at follow-up. Both the TENS + TRTT and the placebo-TENS + TRTT groups had significantly greater improvements in isometric peak trunk flexion torque and extension torque, lateral seated reaching distance to affected and unaffected side, and TIS score than the control group after 3 weeks of training. The TENS + TRTT group had significantly greater and earlier improvement in its mean TIS score than the other 2 groups. Home-based TRTT is effective for improving trunk muscle strength, sitting functional reach and trunk motor control after stroke in subjects without somatosensory deficits. The addition of TENS to the trunk augments the effectiveness of the exercise in terms of TIS scores within the first 3 weeks of training. © The Author(s) 2014.
Modeling of postural stability borders during heel-toe rocking.
Murnaghan, Chantelle D; Elston, Beth; Mackey, Dawn C; Robinovitch, Stephen N
2009-08-01
To maintain balance during movements such as bending and reaching, the CNS must generate muscle forces to counteract destabilizing torques produced by gravitational (position-dependent) and inertial (acceleration-dependent) forces. This may create a trade-off between the attainable frequency and amplitude of movements. We used experiments and mathematical modeling to examine this relationship during the task of heel-toe rocking. During the experiments, participants (n=15) rocked about the ankles in the sagittal plane with maximum attainable amplitude at a frequency of 0.33 Hz or 0.66 Hz. As the frequency doubled, the maximum anterior position of the whole-body centre-of-gravity (COG) with respect to the ankle decreased by 11% of foot length (from 11.9 cm (S.D. 1.6) to 9.2 cm (S.D. 1.2); p<0.001), the minimum anterior position of the COG increased by 8% of foot length (from 1.6 cm to 3.5 cm in front on the ankle; p<0.0005), and the ankle stiffness increased from 787 Nm/rad (S.D. 156) to 1625 Nm/rad (S.D. 339). However, there was no difference between conditions in the maximum anterior position of the COP (p=0.51), the minimum anterior position of the COP (p=0.23), or the peak ankle torque (p=0.39). An inverted pendulum model driven by a rotational spring predicted the measured ankle stiffness to within 0.9% (S.D. 6.8), and the maximum anterior COG position to within 1.2% (S.D. 4.0). These results indicate that COG amplitude decreases with increasing rocking frequency, due to (a) invariability in peak ankle torque and (b) the need to allocate torque between gravitational and inertial components, the latter of which scales with the square of frequency.
Gorselink, M; Drost, M R; de Louw, J; Willems, P J; Hesselink, M K; Dekkers, E C; Rosielle, N; van der Vusse, G J
2001-05-01
The availability of animal models with disrupted genes has increased the need for small-scale measurement devices. Recently, we developed an experimental device to assess in situ mechanical properties of isometric contractions of intact muscle complexes of the mouse. Although this apparatus provides valuable information on muscle mechanical performance, it is not appropriate for determining contractile properties during shortening and lengthening contractions. In the present study we therefore developed and evaluated an experimental apparatus for assessment of shortening and lengthening contractile properties of intact plantar and dorsal flexors of the mouse. The current through a custom-built, low-inertia servomotor was measured to assess contractile muscular torque ranging from -50 to mN.m. Evaluation of the fixation procedure of the animal to the apparatus via 3-D monitoring of the muscle-tendon complex length showed that the additional shortening in length due to a contraction with maximal torque output has only minor effects on the measured torque. Furthermore, misalignment of the axis of rotation of the apparatus relative to the axis of rotation in the ankle joint, i.e. eccentricity, during a routine experiment was estimated to be less than 1.0 mm and hence did not influence the measured torque output under our experimental conditions. Peak power per unit muscle mass (mean +/- SD) of intact dorsal and plantar flexors was 0.27 +/- 0.02 and 0.19 +/- 0.03 W.g-1, respectively. The angular velocity at maximal peak power generated by the dorsal flexor complex and the plantar flexor complex was 1100 +/- 190 and 700 +/- 90 degrees.s-1, respectively.
Effect of Different Levels of Localized Muscle Fatigue on Knee Position Sense
Gear, William S.
2011-01-01
There is little information available regarding how proprioceptive abilities decline as the amount of exertion increases during exercise. The purpose of this study was to determine the role of different levels of fatigue on knee joint position sense. A repeated measures design was used to examine changes in active joint reposition sense (AJRS) prior to and following three levels of fatigue. Eighteen participants performed knee extension and flexion isokinetic exercise until torque output was 90%, 70%, or 50% of the peak hamstring torque for three consecutive repetitions. Active joint reposition sense at 15, 30, or 45 degrees was tested following the isokinetic exercise session. Following testing of the first independent measure, participants were given a 20 minute rest period. Testing procedures were repeated for two more exercise sessions following the other levels of fatigue. Testing of each AJRS test angle was conducted on three separate days with 48 hours between test days. Significant main effect for fatigue was indicated (p = 0.001). Pairwise comparisons indicated a significant difference between the pre-test and following 90% of peak hamstring torque (p = 0.02) and between the pre-test and following 50% of peak hamstring torque (p = 0.02). Fatigue has long been theorized to be a contributing factor in decreased proprioceptive acuity, and therefore a contributing factor to joint injury. The findings of the present study indicate that fatigue may have an effect on proprioception following mild and maximum fatigue. Key points A repeated measures design was used to examine the effect of different levels of fatigue on active joint reposition sense (AJRS) of the knee at joint angles of 15°, 30° and 45° of flexion. A statistically significant main effect for fatigue was found, specifically between no fatigue and mild fatigue and no fatigue and maximum fatigue. A statistically significant interaction effect between AJRS and fatigue was not found. Secondary analysis of the results indicated a potential plateau effect of AJRS as fatigue continues to increase. Further investigation of the effect of increasing levels of fatigue on proprioception is warranted. PMID:24149565
Effect of different levels of localized muscle fatigue on knee position sense.
Gear, William S
2011-01-01
There is little information available regarding how proprioceptive abilities decline as the amount of exertion increases during exercise. The purpose of this study was to determine the role of different levels of fatigue on knee joint position sense. A repeated measures design was used to examine changes in active joint reposition sense (AJRS) prior to and following three levels of fatigue. Eighteen participants performed knee extension and flexion isokinetic exercise until torque output was 90%, 70%, or 50% of the peak hamstring torque for three consecutive repetitions. Active joint reposition sense at 15, 30, or 45 degrees was tested following the isokinetic exercise session. Following testing of the first independent measure, participants were given a 20 minute rest period. Testing procedures were repeated for two more exercise sessions following the other levels of fatigue. Testing of each AJRS test angle was conducted on three separate days with 48 hours between test days. Significant main effect for fatigue was indicated (p = 0.001). Pairwise comparisons indicated a significant difference between the pre-test and following 90% of peak hamstring torque (p = 0.02) and between the pre-test and following 50% of peak hamstring torque (p = 0.02). Fatigue has long been theorized to be a contributing factor in decreased proprioceptive acuity, and therefore a contributing factor to joint injury. The findings of the present study indicate that fatigue may have an effect on proprioception following mild and maximum fatigue. Key pointsA repeated measures design was used to examine the effect of different levels of fatigue on active joint reposition sense (AJRS) of the knee at joint angles of 15°, 30° and 45° of flexion.A statistically significant main effect for fatigue was found, specifically between no fatigue and mild fatigue and no fatigue and maximum fatigue.A statistically significant interaction effect between AJRS and fatigue was not found.Secondary analysis of the results indicated a potential plateau effect of AJRS as fatigue continues to increase.Further investigation of the effect of increasing levels of fatigue on proprioception is warranted.
Nyland, Mark A; Lanting, Brent A; Nikolov, Hristo N; Somerville, Lyndsay E; Teeter, Matthew G; Howard, James L
2016-12-01
It is common practice to burr custom holes in revision porous metal cups for screw insertion. The objective of this study was to determine how different hole types affect a surgeon's sense of screw fixation. Porous revision cups were prepared with pre-drilled and custom burred holes. Cups were held in place adjacent to synthetic bone material of varying density. Surgeons inserted screws through the different holes and materials. Surgeon subjective rating, compression, and torque was recorded. The torque achieved was greater ( p = 0.002) for screws through custom holes than pre-fabricated holes in low and medium density material, with no difference for high density. Peak compression was greater ( p = 0.026) through the pre-fabricated holes only in high density material. Use of burred holes affects the torque generated, and may decrease the amount of cup-acetabulum compression achieved.
Miyahara, Yuka; Jitkritsadakul, Onanong; Sringean, Jirada; Aungkab, Nicharee; Khongprasert, Surasa; Bhidayasiri, Roongroj
2018-04-01
Muscle weakness is a frequent complaint amongst Parkinson's disease (PD) patients. However, evidence-based therapeutic options for this symptom are limited. We objectively measure the efficacy of therapeutic Thai massage (TTM) on upper limb muscle strength, using an isokinetic dynamometer. A total of 60 PD patients with muscle weakness that is not related to their 'off' periods or other neurological causes were equally randomized to TTM intervention (n = 30), consisting of six TTM sessions over a 3-week period, or standard medical care (no intervention, n = 30). Primary outcomes included peak extension and flexion torques. Scale-based outcomes, including Unified Parkinson's Disease Rating Scale (UPDRS) and visual analogue scale for pain (VAS) were also performed. From baseline to end of treatment, patients in the intervention group showed significant improvement on primary objective outcomes, including peak flexion torque (F = 30.613, p < .001) and peak extension torque (F = 35.569, p < .001) and time to maximal flexion speed (F = 14.216, p = .001). Scale-based assessments mirrored improvements in the objective outcomes with a significant improvement from baseline to end of treatment of the UPDRS-bradykinesia of a more affected upper limb (F = 9.239, p = .005), and VAS (F = 69.864, p < .001) following the TTM intervention, compared to the control group. No patients reported adverse events in association with TTM. Our findings provide objective evidence that TTM used in combination with standard medical therapies is effective in improving upper limb muscle strength in patients with PD. Further studies are needed to determine the efficacy of TTM on other motor and non-motor symptoms in PD.
Chen, Chee Keong; Hamdan, Nor Faeiza; Ooi, Foong Kiew; Wan Abd Hamid, Wan Zuraida
2016-01-01
This study investigated the effects of Lignosus rhinocerotis (LRS) supplementation and resistance training (RT) on isokinetic muscular strength and power, anaerobic and aerobic fitness, and immune parameters in young males. Participants were randomly assigned to four groups: Control (C), LRS, RT, and combined RT-LRS (RT-LRS). Participants in the LRS and RT-LRS groups consumed 500 mg of LRS daily for 8 weeks. RT was conducted 3 times/week for 8 weeks for participants in the RT and RT-LRS groups. The following parameters were measured before and after the intervention period: Anthropometric data, isokinetic muscular strength and power, and anaerobic and aerobic fitness. Blood samples were also collected to determine immune parameters. Isokinetic muscular strength and power were increased ( P < 0.05) in participants of both RT and RT-LRS groups. RT-LRS group had shown increases ( P < 0.05) in shoulder extension peak torque, shoulder flexion and extension average power, knee flexion peak torque, and knee flexion and extension average power. There were also increases ( P < 0.05) in anaerobic power and capacity and aerobic fitness in this group. Similarly, RT group had increases ( P < 0.05) in shoulder flexion average power, knee flexion and extension peak torque, and knee flexion and extension average power. In addition, increases ( P < 0.05) in anaerobic power and capacity, aerobic fitness, T lymphocytes (CD3 and CD4), and B lymphocytes (CD19) counts were observed in the RT group. RT elicited increased isokinetic muscular strength and power, anaerobic and aerobic fitness, and immune parameters among young males. However, supplementation with LRS during RT did not provide additive benefits.
Chen, Chee Keong; Hamdan, Nor Faeiza; Ooi, Foong Kiew; Wan Abd Hamid, Wan Zuraida
2016-01-01
Background: This study investigated the effects of Lignosus rhinocerotis (LRS) supplementation and resistance training (RT) on isokinetic muscular strength and power, anaerobic and aerobic fitness, and immune parameters in young males. Methods: Participants were randomly assigned to four groups: Control (C), LRS, RT, and combined RT-LRS (RT-LRS). Participants in the LRS and RT-LRS groups consumed 500 mg of LRS daily for 8 weeks. RT was conducted 3 times/week for 8 weeks for participants in the RT and RT-LRS groups. The following parameters were measured before and after the intervention period: Anthropometric data, isokinetic muscular strength and power, and anaerobic and aerobic fitness. Blood samples were also collected to determine immune parameters. Results: Isokinetic muscular strength and power were increased (P < 0.05) in participants of both RT and RT-LRS groups. RT-LRS group had shown increases (P < 0.05) in shoulder extension peak torque, shoulder flexion and extension average power, knee flexion peak torque, and knee flexion and extension average power. There were also increases (P < 0.05) in anaerobic power and capacity and aerobic fitness in this group. Similarly, RT group had increases (P < 0.05) in shoulder flexion average power, knee flexion and extension peak torque, and knee flexion and extension average power. In addition, increases (P < 0.05) in anaerobic power and capacity, aerobic fitness, T lymphocytes (CD3 and CD4), and B lymphocytes (CD19) counts were observed in the RT group. Conclusions: RT elicited increased isokinetic muscular strength and power, anaerobic and aerobic fitness, and immune parameters among young males. However, supplementation with LRS during RT did not provide additive benefits. PMID:27833721
Profiling Isokinetic Strength by Leg Preference and Position in Rugby Union Athletes.
Brown, Scott R; Brughelli, Matt; Bridgeman, Lee A
2016-05-01
Muscle imbalances aid in the identification of athletes at risk for lower-extremity injury. Little is known regarding the influence that leg preference or playing position may have on lower-extremity muscle strength and asymmetry. To investigate lower-extremity strength profiles in rugby union athletes and compare isokinetic knee- and hip-strength variables between legs and positions. Thirty male academy rugby union athletes, separated into forwards (n = 15) and backs (n = 15), participated in this cross-sectional analysis. Isokinetic dynamometry was used to evaluate peak torque, angle of peak torque, and strength ratios of the preferred and nonpreferred legs during seated knee extension/flexion and supine hip extension/flexion at 60°/s. Backs were older (ES = 1.6) but smaller in stature (ES = -0.47) and body mass (ES = -1.3) than the forwards. The nonpreferred leg was weaker than the preferred leg for forwards during extension (ES = -0.37) and flexion (ES = -0.21) actions and for backs during extension (ES = -0.28) actions. Backs were weaker at the knee than forwards in the preferred leg during extension (ES = -0.50) and flexion (ES = -0.66) actions. No differences were observed in strength ratios between legs or positions. Backs produced peak torque at longer muscle lengths in both legs at the knee (ES = -0.93 to -0.94) and hip (ES = -0.84 to -1.17) than the forwards. In this sample of male academy rugby union athletes, the preferred leg and forwards displayed superior strength compared with the nonpreferred leg and backs. These findings highlight the importance of individualized athletic assessments to detect crucial strength differences in male rugby union athletes.
McKinlay, Brandon John; Wallace, Phillip; Dotan, Raffy; Long, Devon; Tokuno, Craig; Gabriel, David; Falk, Bareket
2018-01-04
This study examined the effect of 8-weeks of free-weight-resistance (RT) and plyometric (PLYO) training on maximal strength, explosiveness and jump performance compared with no added training (CON), in young male soccer players. Forty-one 11[FIGURE DASH]13-year-old soccer players were divided into three groups (RT, PLYO, CON). All participants completed isometric and dynamic (240°/s) knee extensions pre- and post-training. Peak torque (pT), peak rate of torque development (pRTD), electromechanical-delay (EMD), rate of muscle activation (Q50), m. vastus-lateralis thickness (VLT), and jump performance were examined. pT, pRTD and jump performance significantly improved in both training groups. Training resulted in significant (p<0.05) increases in isometric pT (23.4 vs. 15.8%) and pRTD (15.0 vs. 17.6%), in RT and PLYO, respectively. During dynamic contractions, training resulted in significant increases in pT (12.4 and 10.8% in RT and PLYO, respectively), but not pRTD. Jump performance increased in both training groups (RT=10.0%, PLYO=16.2%), with only PLYO significantly different from CON. Training resulted in significant increases in VLT (RT=6.7%. PLYO=8.1%). There were no significant EMD changes. In conclusion, 8-week free-weight resistance and plyometric training resulted in significant improvements in muscle strength and jump performance. Training resulted in similar muscle hypertrophy in the two training modes, with no clear differences in muscle performance. Plyometric training was more effective in improving jump performance, while free-weight resistance training was more advantageous in improving peak torque, where the stretch reflex was not involved.
Trunk extensor and flexor strength of long-distance race car drivers and physically active controls.
Baur, Heiner; Muller, Steffen; Pilz, Frederike; Mayer, Patrizia; Mayer, Frank
2010-09-01
Seventy percent of motor sports athletes report low back pain. Information on the physical capacity of race car drivers is limited. The purpose of this study was to compare the maximum trunk extensor and flexor strength of elite race car drivers and physically active controls. Thirteen elite race car drivers and 13 controls were measured in concentric mode for maximal trunk flexion and extension at 60° x s(-1) and 120° x s(-1). Peak torque (mean ± s) at 60° x s(-1) in trunk extension was 283 ± 80 N x m in the drivers and 260 ± 88 N x m in controls (P > 0.05). At 120° x s(-1), drivers produced peak torques of 248 ± 55 N x m compared with 237 ± 74 N x m for controls (P > 0.05). Peak torques in flexion were less than in extension for both groups (60° x s(-1): drivers 181 ± 56 N x m, controls 212 ± 54 N x m, P > 0.05; 120° x s(-1): drivers 191 ± 57 N x m, controls 207 ± 48 N x m, P > 0.05). Individual ratios of flexion to extension forces exhibited ratios of 0.88 (60° x s(-1)) and 0.93 (120° x s(-1)) for controls and 0.66 (60° x s(-1)) and 0.77 (120° x s(-1)) for drivers (60° x s(-1): P > 0.05; 120° x s(-1): P > 0.05). The maximum strength performance capacity of the trunk muscles of elite motor sport athletes competing in long-distance racing did not differ from that of anthropometrically matched and physically active controls.
Aoki, Kosuke; Nakao, Atsunori; Adachi, Takako; Matsui, Yasushi; Miyakawa, Shumpei
2012-01-01
Muscle contraction during short intervals of intense exercise causes oxidative stress, which can play a role in the development of overtraining symptoms, including increased fatigue, resulting in muscle microinjury or inflammation. Recently it has been said that hydrogen can function as antioxidant, so we investigated the effect of hydrogen-rich water (HW) on oxidative stress and muscle fatigue in response to acute exercise. Ten male soccer players aged 20.9 ± 1.3 years old were subjected to exercise tests and blood sampling. Each subject was examined twice in a crossover double-blind manner; they were given either HW or placebo water (PW) for one week intervals. Subjects were requested to use a cycle ergometer at a 75 % maximal oxygen uptake (VO2) for 30 min, followed by measurement of peak torque and muscle activity throughout 100 repetitions of maximal isokinetic knee extension. Oxidative stress markers and creatine kinase in the peripheral blood were sequentially measured. Although acute exercise resulted in an increase in blood lactate levels in the subjects given PW, oral intake of HW prevented an elevation of blood lactate during heavy exercise. Peak torque of PW significantly decreased during maximal isokinetic knee extension, suggesting muscle fatigue, but peak torque of HW didn't decrease at early phase. There was no significant change in blood oxidative injury markers (d-ROMs and BAP) or creatine kinease after exercise. Adequate hydration with hydrogen-rich water pre-exercise reduced blood lactate levels and improved exercise-induced decline of muscle function. Although further studies to elucidate the exact mechanisms and the benefits are needed to be confirmed in larger series of studies, these preliminary results may suggest that HW may be suitable hydration for athletes.
Human torque velocity adaptations to sprint, endurance, or combined modes of training
NASA Technical Reports Server (NTRS)
Shealy, M. J.; Callister, R.; Dudley, G. A.; Fleck, S. J.
1992-01-01
We had groups of athletes perform sprint and endurance run training independently or concurrently for 8 weeks to examine the voluntary in vivo mechanical responses to each type of training. Pre- and posttraining angle-specific peak torque during knee extension and flexion were determined at 0, 0.84, 1.65, 2.51, 3.35, 4.19, and 5.03 radian.sec-1 and normalized for lean body mass. Knee extension torque in the sprint-trained group increased across all test velocities, the endurance-trained group increased at 2.51, 3.34, 4.19, and 5.03 radian.sec-1, and the group performing the combined training showed no change at any velocity. Knee flexion torque of the sprint and combined groups decreased at 0.84, 1.65, and 2.51 radian.sec-1. Knee flexion torque in the sprint-trained group also decreased at 0 radian.sec-1 and in the combined group at 3.34 radian.sec-1. Knee flexion torque in the endurance-trained group showed no change at any velocity of contraction. Mean knee flexion:extension ratios across the test velocities significantly decreased in the sprint-trained group. Knee extension endurance during 30 seconds of maximal contractions significantly increased in all groups. Only the sprint-trained group showed a significant increase in endurance of the knee flexors. These data suggest that changes in the voluntary in vivo mechanical characteristics of knee extensor and flexor skeletal muscles are specific to the type of run training performed.
Does maximum torque mean optimal pullout strength of screws?
Tankard, Sara E; Mears, Simon C; Marsland, Daniel; Langdale, Evan R; Belkoff, Stephen M
2013-04-01
To determine the relationship between insertion torque and pullout strength of 3.5-mm-diameter cortical screws in cadaveric humeri with different bone mineral densities (BMDs). Five pairs of human humeri from each of 3 BMD groups (normal, osteopenic, and osteoporotic) were used. Holes were drilled in each humerus, and maximum insertion torque (T(max)) was measured by tightening a screw until stripping occurred. In the remaining holes, screws were tightened to 50%, 70%, or 90% of the T(max). A servohydraulic testing machine pulled each screw out at 1 mm/s while resulting force and axial displacement were recorded at 10 Hz. The authors checked for an effect of insertion torque (percent T(max)) on pullout strength using a general linearized and latent mixed model (Stata10), controlling for cortical thickness and BMD (T-score). Pullout strength for normal and osteoporotic bone was greatest for screws inserted to 50% T(max) and was significantly greater than that at T(max) but not significantly different from that at 70% or 90% T(max). For osteopenic bone, pullout strength was greatest at 70% peak torque, but it was not significantly different from the pullout strength at the 50% or 90% T(max) levels. Tightening screws beyond 50% T(max) does not increase pullout strength of the screw and may place bone at risk for damage that might result in loss of fixation. Even after adjusting for bone thickness and density, there is no clear relationship between pullout strength and screw torque.
Medeiros, Flávia Vanessa; Bottaro, Martim; Vieira, Amilton; Lucas, Tiago Pires; Modesto, Karenina Arrais; Bo, Antonio Padilha L; Cipriano, Gerson; Babault, Nicolas; Durigan, João Luiz Quagliotti
2017-06-01
To test the hypotheses that, as compared with pulsed current with the same pulse duration, kilohertz frequency alternating current would not differ in terms of evoked-torque production and perceived discomfort, and as a result, it would show the same current efficiency. A repeated-measures design with 4 stimuli presented in random order was used to test 25 women: (1) 500-microsecond pulse duration, (2) 250-microsecond pulse duration, (3) 500-microsecond pulse duration and low carrier frequency (1 kHz), (4) 250-microsecond pulse duration and high carrier frequency (4 kHz). Isometric peak torque of quadriceps muscle was measured using an isokinetic dynamometer. Discomfort was measured using a visual analog scale. Currents with long pulse durations induced approximately 21% higher evoked torque than short pulse durations. In addition, currents with 500 microseconds delivered greater amounts of charge than stimulation patterns using 250-microsecond pulse durations (P < 0.05). All currents presented similar discomfort. There was no difference on stimulation efficiency with the same pulse duration. Both kilohertz frequency alternating current and pulsed current, with the same pulse duration, have similar efficiency for inducing isometric knee extension torque and discomfort. However, neuromuscular electrical stimulation (NMES) with longer pulse duration induces higher NMES-evoked torque, regardless of the carrier frequency. Pulse duration is an important variable that should receive more attention for an optimal application of NMES in clinical settings.
Bacchi, Atais; Regalin, Alexandre; Bhering, Claudia Lopes Brilhante; Alessandretti, Rodrigo; Spazzin, Aloisio Oro
2015-10-01
The purpose of this study was to evaluate the influence of tightening technique and the screw coating on the loosening torque of screws used for Universal Abutment fixation after cyclic loading. Forty implants (Titamax Ti Cortical, HE, Neodent) (n=10) were submerged in acrylic resin and four tightening techniques for Universal Abutment fixation were evaluated: A - torque with 32 Ncm (control); B - torque with 32 Ncm holding the torque meter for 20 seconds; C - torque with 32 Ncm and retorque after 10 minutes; D - torque (32 Ncm) holding the torque meter for 20 seconds and retorque after 10 minutes as initially. Samples were divided into subgroups according to the screw used: conventional titanium screw or diamond like carbon-coated (DLC) screw. Metallic crowns were fabricated for each abutment. Samples were submitted to cyclic loading at 10(6) cycles and 130 N of force. Data were analyzed by two-way ANOVA and Tukey's test (5%). The tightening technique did not show significant influence on the loosening torque of screws (P=.509). Conventional titanium screws showed significant higher loosening torque values than DLC (P=.000). The use of conventional titanium screw is more important than the tightening techniques employed in this study to provide long-term stability to Universal Abutment screws.
Lee, Justin W Y; Cai, Ming-Jing; Yung, Patrick S H; Chan, Kai-Ming
2018-05-01
To evaluate the test-retest reliability, sensitivity, and concurrent validity of a smartphone-based method for assessing eccentric hamstring strength among male professional football players. A total of 25 healthy male professional football players performed the Chinese University of Hong Kong (CUHK) Nordic break-point test, hamstring fatigue protocol, and isokinetic hamstring strength test. The CUHK Nordic break-point test is based on a Nordic hamstring exercise. The Nordic break-point angle was defined as the maximum point where the participant could no longer support the weight of his body against gravity. The criterion for the sensitivity test was the presprinting and postsprinting difference of the Nordic break-point angle with a hamstring fatigue protocol. The hamstring fatigue protocol consists of 12 repetitions of the 30-m sprint with 30-s recoveries between sprints. Hamstring peak torque of the isokinetic hamstring strength test was used as the criterion for validity. A high test-retest reliability (intraclass correlation coefficient = .94; 95% confidence interval, .82-.98) was found in the Nordic break-point angle measurements. The Nordic break-point angle significantly correlated with isokinetic hamstring peak torques at eccentric action of 30°/s (r = .88, r 2 = .77, P < .001). The minimal detectable difference was 8.03°. The sensitivity of the measure was good enough that a significance difference (effect size = 0.70, P < .001) was found between presprinting and postsprinting values. The CUHK Nordic break-point test is a simple, portable, quick smartphone-based method to provide reliable and accurate eccentric hamstring strength measures among male professional football players.
Braito, Matthias; Giesinger, Johannes M; Fischler, Stefan; Koller, Arnold; Niederseer, David; Liebensteiner, Michael C
2016-08-01
In light of the existing lack of evidence, it was the aim of this study to compare gait characteristics and knee extensor strength after medial unicondylar knee arthroplasty (MUKA) with those after total knee arthroplasty (TKA), given the same standardized minimally invasive surgery (MIS) approach in both groups. Patients scheduled for MIS-MUKA or MIS-TKA as part of clinical routine were invited to participate. A posterior cruciate ligament-retaining total knee design was used for all MIS-TKA. A 3-dimensional gait analysis was performed preoperatively with a VICON system and at 8 weeks postoperative to determine temporospatial parameters, ground reaction forces, joint angles, and joint moments. At the same 2 times, isokinetic tests were performed to obtain peak values of knee extensor torque. A multivariate analysis of variance was conducted and included the main effects time (before and after surgery) and surgical group and the group-by-time interaction effect. Fifteen MIS-MUKA patients and 17 MIS-TKA patients were eligible for the final analysis. The groups showed no differences regarding age, body mass index, sex, side treated, or stage of osteoarthritis. We determined neither intergroup differences nor time × group interactions for peak knee extensor torque or any gait parameters (temporospatial, ground reaction forces, joint angles, and joint moments). It is concluded that MUKA is not superior to TKA with regard to knee extensor strength or 3-dimensional gait characteristics at 8 weeks after operation. As gait characteristics and knee extensor strength are only 2 of the various potential outcome parameters (knee scores, activity scores…) and quadriceps strength might take a longer time to recover, our findings should be interpreted with caution. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
Body Mass Bias in a Combat Fitness Test
2011-02-07
Allometric scaling of isokinetic peak torque: The Nebraska Wrestling Study. European Journal of Applied Physiology, 80, 240–248. White, C. R...applied to the Movement and 3-mi run times after converting times to velocity (in meters ). The estimated metabolic rate mass coefficients were
Ahn, Ick Keun; Kim, You Lim; Bae, Young-Hyeon; Lee, Suk Min
2015-01-01
Objectives. The purpose of this cross-sectional single-blind study was to investigate the immediate effects of Kinesiology taping of quadriceps on motor performance after muscle fatigued induction. Design. Randomized controlled cross-sectional design. Subjects. Forty-five subjects participated in this study. Participants were divided into three groups: Kinesiology taping group, placebo taping group, and nontaping group. Methods. Subjects performed short-term exercise for muscle fatigued induction, followed by the application of each intervention. Peak torque test, one-leg single hop test, active joint position sense test, and one-leg static balance test were carried out before and after the intervention. Results. Peak torque and single-leg hopping distance were significantly increased when Kinesiology taping was applied (p < 0.05). But there were no significant effects on active joint position sense and single-leg static balance. Conclusions. We proved that Kinesiology taping is effective in restoring muscle power reduced after muscle fatigued induction. Therefore, we suggest that Kinesiology taping is beneficial for fatigued muscles.
Gear tooth stress measurements on the UH-60A helicopter transmission
NASA Technical Reports Server (NTRS)
Oswald, Fred B.
1987-01-01
The U.S. Army UH-60A (Black Hawk) 2200-kW (3000-hp) class twin-engine helicopter transmission was tested at the NASA Lewis Research Center. Results from these experimental (strain-gage) stress tests will enhance the data base for gear stress levels in transmissions of a similar power level. Strain-gage measurements were performed on the transmission's spiral-bevel combining pinions, the planetary Sun gear, and ring gear. Tests were performed at rated speed and at torque levels 25 to 100 percent that of rated. One measurement series was also taken at a 90 percent speed level. The largest stress found was 760 MPa (110 ksi) on the combining pinion fillet. This is 230 percent greater than the AGMA index stress. Corresponding mean and alternating stresses were 300 and 430 MPa (48 and 62 ksi). These values are within the range of successful test experience reported for other transmissions. On the fillet of the ring gear, the largest stress found was 410 MPa (59 ksi). The ring-gear peak stress was found to be 11 percent less than an analytical (computer simulation) value and it is 24 percent greater than the AGMA index stress. A peak compressive stress of 650 MPa (94 ksi) was found at the center of the Sun gear tooth root.
Hoglund, Lisa T; Pontiggia, Laura; Kelly, John D
2018-01-01
Patellofemoral joint (PFJ) osteoarthritis (OA) is prevalent in middle-aged and older adults. Despite this, there are minimal studies which have examined conservative interventions for PFJ OA. Weakness of proximal lower extremity muscles is associated with PFJ OA. It is unknown if a hip muscle strengthening and lumbopelvic-hip core stabilization program will improve symptoms and function in persons with PFJ OA. This study examined the feasibility and impact of a 6-week hip muscle strengthening and core stabilization program on pain, symptoms, physical performance, peak muscle torques, and quality of life in persons with PFJ OA. Ten females with PFJ OA and ten age- and sex-matched controls participated in baseline tests. PFJ OA participants attended ten twice-a-week hip strengthening and core stabilization exercise sessions. Outcome measures included questionnaires, the Timed-Up-and-Go, and peak isometric torque of hip and quadriceps muscles. Data were tested for normality; parametric and non-parametric tests were used as appropriate. At baseline, the PFJ OA group had significantly worse symptoms, slower Timed-Up-and-Go performance, and lower muscle torques than control participants. PFJ OA group adherence to supervised exercise sessions was adequate. All PFJ OA participants attended at least nine exercise sessions. Five PFJ OA participants returned 6-month follow-up questionnaires, which was considered fair retention. The PFJ OA participants' self-reported pain, symptoms, function in daily living, function in sport, and quality of life all improved at 6 weeks ( P < 0.05). Timed-Up-and-Go time score improved at 6 weeks ( P = 0.005). Peak hip external rotator torque increased ( P = 0.01). Improvements in pain and self-reported function were no longer significant 6 months following completion of the intervention. PFJ OA participants were adherent to the supervised sessions of the intervention. Improvement in symptoms, physical performance, and muscle torque were found after 6 weeks. Participant retention at 6 months was fair, and significant changes were no longer present. Our findings suggest that a hip strengthening and core stabilization program may be beneficial to improve symptoms, function, and physical performance in persons with PFJ OA. Future studies are needed, and additional measures should be taken to improve long-term adherence to exercise. ClinicalTrials.gov NCT02825238. Registered 6 July 2016 (retrospectively registered).
Lienhard, K; Lauermann, S P; Schneider, D; Item-Glatthorn, J F; Casartelli, N C; Maffiuletti, N A
2013-12-01
Reliability of isometric, isokinetic and isoinertial modalities for quadriceps strength evaluation, and the relation between quadriceps strength and physical function was investigated in 29 total knee arthroplasty (TKA) patients, with an average age of 63 years. Isometric maximal voluntary contraction torque, isokinetic peak torque, and isoinertial one-repetition maximum load of the involved and uninvolved quadriceps were evaluated as well as objective (walking parameters) and subjective physical function (WOMAC). Reliability was good and comparable for the isometric, isokinetic, and isoinertial strength outcomes on both sides (intraclass correlation coefficient range: 0.947-0.966; standard error of measurement range: 5.1-9.3%). Involved quadriceps strength was significantly correlated to walking speed (r range: 0.641-0.710), step length (r range: 0.685-0.820) and WOMAC function (r range: 0.575-0.663), independent from the modality (P < 0.05). Uninvolved quadriceps strength was also significantly correlated to walking speed (r range: 0.413-0.539), step length (r range: 0.514-0.608) and WOMAC function (r range: 0.374-0.554) (P < 0.05), except for WOMAC function/isokinetic peak torque (P > 0.05). In conclusion, isometric, isokinetic, and isoinertial modalities ensure valid and reliable assessment of quadriceps muscle strength in TKA patients. Copyright © 2013 Elsevier Ltd. All rights reserved.
Child–adult differences in the kinetics of torque development
DOTAN, RAFFY; MITCHELL, CAMERON; COHEN, ROTEM; GABRIEL, DAVID; KLENTROU, PANAGIOTA; FALK, BAREKET
2013-01-01
Children have lower size-normalised maximal voluntary force, speed, and power than adults. It has been hypothesised that these and other age-related performance differences are due to lesser type-II motor-unit utilisation in children. This should be manifested as slower force kinetics in explosive muscle contractions. The purpose of this study was to investigate the nature of child–adult force-kinetics differences and whether the latter could support that hypothesis. Untrained boys (n = 20) and men (n = 20) (10.1 ± 1.3 and 22.9 ± 4.4 years, respectively), performed maximal, explosive, isometric elbow flexions and knee extensions on a Biodex dynamometer. Peak torque (MVC), times to 10–100% MVC, and other kinetics parameters were determined. The boys’ body-mass-normalised knee extension MVC, peak rate of torque development, and %MVC at 100 ms were 26, 17 and 23% lower compared with the men and their times to 30% and 80% MVC were 24 and 48% longer, respectively. Elbow flexion kinetics showed similar or greater differences. The findings illuminate boys’ inherent disadvantage in tasks requiring speed or explosive force. It is demonstrated that the extent of the boys–men kinetics disparity cannot be explained by muscle-composition and/or musculo-tendinous-stiffness differences. We suggest therefore that the findings indirectly support children’s lower utilisation of type-II motor units. PMID:23320937
Circuit increases capability of hysteresis synchronous motor
NASA Technical Reports Server (NTRS)
Markowitz, I. N.
1967-01-01
Frequency and phase detector circuit enables a hysteresis synchronous motor to drive a load of given torque value at a precise speed determined by a stable reference. This technique permits driving larger torque loads with smaller motors and lower power drain.
Yilmaz, Burak; L'Homme-Langlois, Emilie; Beck, Frank M; McGlumphy, Edwin
2016-06-01
Two types of mechanical torque-limiting devices (MTLD) are available: friction-style and spring-style. Limited information is available regarding the accuracy of different types of MTLDs after sterilization. The purpose of this in vitro study was to determine the accuracy of MTLDs after sterilization. Three new friction-style and 3 new spring-style MTLDs (Astra Tech/Dentsply, Zimmer Dental, Biohorizons, Biomet 3i, Straumann [ITI] and Nobel Biocare; n=5 per manufacturer; 30 total) were selected to evaluate their accuracy in delivering the target torque values preset by their manufacturers before and after sterilization. Target torque measurements were made with a digital torque gauge (model DFS2-R-ND; Chatillon) 10 times for each device. All MTLDs were sterilized following the manufacturers' recommendations. The sterilization procedure was repeated 100 times, and the accuracy of all MTLDs was retested. Absolute torque differences were analyzed using a repeated measures analysis of variance with instrument as the repeated factor. MTLD type (friction or spring) and MTLD status (new or autoclaved) were the independent variables. Post hoc testing was done using the Tukey method for balanced data. No significant difference was found between the spring-style and friction-style MTLDs or within the spring-style and friction-style MTLDs before and after sterilization (P>.05). After 100 cycles of steam autoclaving, the accuracy of spring-style and friction-style MTLDs was similar. All MTLDs fell within ±10% of the target torque value before and after sterilization. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Do changes in neuromuscular activation contribute to the knee extensor angle-torque relationship?
Lanza, Marcel B; Balshaw, Thomas G; Folland, Jonathan P
2017-08-01
What is the central question of the study? Do changes in neuromuscular activation contribute to the knee extensor angle-torque relationship? What is the main finding and its importance? Both agonist (quadriceps) and antagonist coactivation (hamstrings) differed with knee joint angle during maximal isometric knee extensions and thus both are likely to contribute to the angle-torque relationship. Specifically, two independent measurement techniques showed quadriceps activation to be lower at more extended positions. These effects might influence the capacity for neural changes in response to training and rehabilitation at different knee joint angles. The influence of joint angle on knee extensor neuromuscular activation is unclear, owing in part to the diversity of surface electromyography (sEMG) and/or interpolated twitch technique (ITT) methods used. The aim of the study was to compare neuromuscular activation, using rigorous contemporary sEMG and ITT procedures, during isometric maximal voluntary contractions (iMVCs) of the quadriceps femoris at different knee joint angles and examine whether activation contributes to the angle-torque relationship. Sixteen healthy active men completed two familiarization sessions and two experimental sessions of isometric knee extension and knee flexion contractions. The experimental sessions included the following at each of four joint angles (25, 50, 80 and 106 deg): iMVCs (with and without superimposed evoked doublets); submaximal contractions with superimposed doublets; and evoked twitch and doublet contractions whilst voluntarily passive, and knee flexion iMVC at the same knee joint positions. The absolute quadriceps femoris EMG was normalized to the peak-to-peak amplitude of an evoked maximal M-wave, and the doublet-voluntary torque relationship was used to calculate activation with the ITT. Agonist activation, assessed with both normalized EMG and the ITT, was reduced at the more extended compared with the more flexed positions (25 and 50 versus 80 and 106 deg; P ≤ 0.016), whereas antagonist coactivation was greatest in the most flexed compared with the extended positions (106 versus 25 and 50 deg; P ≤ 0.02). In conclusion, both agonist and antagonist activation differed with knee joint angle during knee extension iMVCs, and thus both are likely to contribute to the knee extensor angle-torque relationship. © 2017 The Authors. Experimental Physiology © 2017 The Physiological Society.
Cheng, Arthur J; Davidson, Andrew W; Rice, Charles L
2010-06-01
The fatigue-related reduction in joint range of motion (ROM) during dynamic contraction tasks may be related to muscle length-dependent alterations in torque and contractile kinetics, but this has not been systematically explored previously. Twelve young men performed a repetitive voluntary muscle shortening contraction task of the dorsiflexors at a contraction load of 30% of maximum voluntary isometric contraction (MVC) torque, until total 40 degrees ROM had decreased by 50% at task failure (POST) to 20 degrees ROM. At both a short (5 degrees dorsiflexion) and long muscle length (35 degrees plantar flexion joint angle relative to a 0 degrees neutral ankle joint position), voluntary activation, MVC torque, and evoked tibialis anterior contractile properties of a 52.8 Hz high-frequency isometric tetanus [peak evoked torque, maximum rate of torque development (MRTD), maximum rate of relaxation (MRR)] were evaluated at baseline (PRE), at POST, and up to 10 min of recovery. At POST, we measured similar fatigue-related reductions in torque (voluntary and evoked) and slowing of contractile kinetics (MRTD and MRR) at both the short and long muscle lengths. Thus, the fatigue-related reduction in ROM could not be explained by length-dependent fatigue. Although torque (voluntary and evoked) at both muscle lengths was depressed and remained blunted throughout the recovery period, this was not related to the rapid recovery of ROM at 0.5 min after task failure. The reduction in ROM, however, was strongly related to the reduction in joint angular velocity (R(2) = 0.80) during the fatiguing task, although additional factors cannot yet be overlooked.
Anderson, Dennis E; Madigan, Michael L
2014-03-21
Limited plantar flexor strength and hip extension range of motion (ROM) in older adults are believed to underlie common age-related differences in gait. However, no studies of age-related differences in gait have quantified the percentage of strength and ROM used during gait. We examined peak hip angles, hip torques and plantar flexor torques, and corresponding estimates of functional capacity utilized (FCU), which we define as the percentage of available strength or joint ROM used, in 10 young and 10 older healthy adults walking under self-selected and controlled (slow and fast) conditions. Older adults walked with about 30% smaller hip extension angle, 28% larger hip flexion angle, 34% more hip extensor torque in the slow condition, and 12% less plantar flexor torque in the fast condition than young adults. Older adults had higher FCU than young adults for hip flexion angle (47% vs. 34%) and hip extensor torque (48% vs. 27%). FCUs for plantar flexor torque (both age groups) and hip extension angle (older adults in all conditions; young adults in self-selected gait) were not significantly <100%, and were higher than for other measures examined. Older adults lacked sufficient hip extension ROM to walk with a hip extension angle as large as that of young adults. Similarly, in the fast gait condition older adults lacked the strength to match the plantar flexor torque produced by young adults. This supports the hypothesis that hip extension ROM and plantar flexor strength are limiting factors in gait and contribute to age-related differences in gait. Copyright © 2014 Elsevier Ltd. All rights reserved.
Predicted torque equilibrium attitude utilization for Space Station attitude control
NASA Technical Reports Server (NTRS)
Kumar, Renjith R.; Heck, Michael L.; Robertson, Brent P.
1990-01-01
An approximate knowledge of the torque equilibrium attitude (TEA) is shown to improve the performance of a control moment gyroscope (CMG) momentum management/attitude control law for Space Station Freedom. The linearized equations of motion are used in conjunction with a state transformation to obtain a control law which uses full state feedback and the predicted TEA to minimize both attitude excursions and CMG peak and secular momentum. The TEA can be computationally determined either by observing the steady state attitude of a 'controlled' spacecraft using arbitrary initial attitude, or by simulating a fixed attitude spacecraft flying in desired orbit subject to realistic environmental disturbance models.
Huang, Hairong; Wismeijer, Daniel; Shao, Xianhong; Wu, Gang
2016-01-01
Objectives The objective of this study is to mathematically evaluate the influence of multiple factors on implant stability quotient values in clinical practice. Patients and methods Resonance frequency analysis was performed at T1 (measured immediately at the time of implant placement) and at T2 (measured before dental restoration) in 177 patients (329 implants). Using a multivariate linear regression model, we analyzed the influence of the following eleven candidate factors: sex, age, maxillary/mandibular location, bone type, immediate/delayed implantation, bone grafting (presence or absence), insertion torque, I-/II-stage healing pattern, implant diameter, implant length, and T1–T2 time interval. Results The following factors were identified to significantly influence the implant stability quotient (ISQ) values at T1: insertion torque, bone grafting, I-/II-stage healing pattern, immediate/delayed implantation, maxillary/mandibular location, implant diameter, and sex. In contrast, the ISQ values at T2 were significantly influenced only by three factors: implant diameter, T1–T2 time interval, and insertion torque. Conclusion Among the eleven candidate factors, seven key factors were found to influence the T1-ISQ values, while only three key factors influenced the T2-ISQ values. Both T1 and T2-ISQ values were found to be influenced by implant diameter and insertion torque. T1 was influenced specifically by the sex of the patient, the location (maxillary or mandibular), the implantation mode (immediate/delayed implantation), the healing stage, and the absence or presence of bone graft materials. PMID:27785040
Herbst, Paulo Eduardo; de Carvalho, Eduardo Bortolas; Salatti, Rafael C; Valgas, Laiz; Tiossi, Rodrigo
To study the force used for tightening tapered one-piece prosthetic abutments and their influence on the removal torque value and stress level of the prosthetic abutment after cyclic loading. Fourteen implants and prosthetic abutments were divided into two groups (n = 7): G1, 20 Ncm; and G2, 32 Ncm (manufacturer recommended). A 20-mm T-shaped horizontal bar was adapted to the abutments. A 12-Hz cyclic loading was applied to the specimens in an electrodynamic testing system with the maximum number of cycles set to 10 6 . Specimens were inclined by 15 degrees from the vertical axis, and a 5-mm off-center vertical load was applied to generate a combination of bending and torquing moments on the tapered connections. Progressive loads (from 164.85 to 362.85 N) were applied when the previous sample survived 10 6 cycles. The paired t test compared the screw removal torque with the initial tightening torque for each group (α = .05). A finite element analysis (FEA) of the mechanical testing analyzed the regions of stress concentration. No specimens failed after 10 6 cyclic loadings. The mean screw removal torque for both groups was similar to the initial abutment torque value applied for each group (G1, 20.36 ± 8.73 Ncm; and G2, 35.61 ± 6.99 Ncm) (P > .05). FEA showed similar stress behavior for both groups in the study despite the different simulated screw preloads (G1: 200 N; G2: 320 N). The coronal region of the implant body presented the highest strain values in both groups. Tightening tapered one-piece prosthetic abutments at 20 and 32 Ncm maintains a stable connection after cyclic loading. The stresses generated by the different tightening forces during cyclic loading are highest at the coronal level of the connection.
Mentiplay, Benjamin F; Tan, Dawn; Williams, Gavin; Adair, Brooke; Pua, Yong-Hao; Bower, Kelly J; Clark, Ross A
2018-04-27
Isometric rate of torque development examines how quickly force can be exerted and may resemble everyday task demands more closely than isometric strength. Rate of torque development may provide further insight into the relationship between muscle function and gait following stroke. Aims of this study were to examine the test-retest reliability of hand-held dynamometry to measure isometric rate of torque development following stroke, to examine associations between strength and rate of torque development, and to compare the relationships of strength and rate of torque development to gait velocity. Sixty-three post-stroke adults participated (60 years, 34 male). Gait velocity was assessed using the fast-paced 10 m walk test. Isometric strength and rate of torque development of seven lower-limb muscle groups were assessed with hand-held dynamometry. Intraclass correlation coefficients were calculated for reliability and Spearman's rho correlations were calculated for associations. Regression analyses using partial F-tests were used to compare strength and rate of torque development in their relationship with gait velocity. Good to excellent reliability was shown for strength and rate of torque development (0.82-0.97). Strong associations were found between strength and rate of torque development (0.71-0.94). Despite high correlations between strength and rate of torque development, rate of torque development failed to provide significant value to regression models that already contained strength. Assessment of isometric rate of torque development with hand-held dynamometry is reliable following stroke, however isometric strength demonstrated greater relationships with gait velocity. Further research should examine the relationship between dynamic measures of muscle strength/torque and gait after stroke. Copyright © 2018 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Irvan; Trisakti, B.; Husaini, T.; Sitio, A.; Sitorus, TB
2017-06-01
Biogas is a flammable gas produced from the fermentation of organic materials by anaerobic bacteria originating from household waste manure and organic waste including palm oil mill effluent (POME). POME is mainly discharged from the sterilization unit of palm oil processing into crude palm oil. This study utilized biogas produced from liquid waste palm oil for use as fuel in the Otto engine generator 4 - stroke, type STARKE GFH1900LX with a peak power of 1.3 kW, 1.0 kW average power, bore 55 mm, stroke 40 mm, Vd 95 × 10-6 m3, Vc 10 × 10-6 m3, compression ratio of 10.5 : 1, and the number of cylinders = 1. The objective of this study is to evaluate the performance of Otto engine generator fueled with biogas that generated from POME, then comparing its performance fueled by gasoline. The performance included power, torque, specific fuel consumption, thermal efficiency, and the air-fuel ratio. Experiment was conducted by using a variation of the lamp load of 100, 200, 300, 400, and 500 W. The results revealed that the use of biogas as fuel decreased in power, torque, brake thermal efficiency, and air fuel ratio (AFR), while there is an increasing of value specific fuel consumption (SFC).
de Souza, Kristopher Mendes; Dekerle, Jeanne; Salvador, Paulo Cesar do Nascimento; de Lucas, Ricardo Dantas; Guglielmo, Luiz Guilherme Antonacci; Greco, Camila Coelho; Denadai, Benedito Sérgio
2016-04-01
What is the central question of this study? Does the rate of utilization of W' (the curvature constant of the power-duration relationship) affect fatigue during severe-intensity exercise? What is the main finding and its importance? The magnitude of fatigue after two severe-intensity exercises designed to deplete the same fraction of W' (70%) at two different rates of utilization (fast versus slow) was similar after both exercises. Moreover, the magnitude of fatigue was related to critical power (CP), supporting the contention that CP is a key determinant in fatigue development during high-intensity exercise. Thus, the CP model is a suitable approach to investigate fatigue mechanisms during high-intensity exercise. The depletion of W' (the curvature constant of the power-duration relationship) seems to contribute to fatigue during severe-intensity exercise. Therefore, the aim of this study was to determine the effect of a fast versus a slow rate of utilization of W' on the occurrence of fatigue within the severe-intensity domain. Fifteen healthy male subjects performed tests to determine the critical power, W' and peak torque in the control condition (TCON ) and immediately after two fatiguing work rates (THREE and TEN) set to deplete 70% W' in either 3 (TTHREE ) or 10 min (TTEN ). The TTHREE and TTEN were significantly reduced (F = 19.68, P = 0.01) in comparison to TCON . However, the magnitude of reduction in peak torque (TTHREE = -19.8 ± 10.1% versus TTEN = -16.8 ± 13.3%) was the same in the two fatiguing exercises (t = -0.76, P = 0.46). There was a significant inverse relationship between the critical power and the reduction in peak torque during both THREE (r = -0.49, P = 0.03) and TEN (r = -0.62, P = 0.02). In contrast, the W' was not significantly correlated with the reduction in peak torque during both THREE (r = -0.14, P = 0.33) and TEN (r = -0.30, P = 0.10). Thus, fatigue following severe-intensity exercises performed at different rates of utilization of W' was similar when the same work was done above the critical power (i.e. same amount of W' used). © 2016 The Authors. Experimental Physiology © 2016 The Physiological Society.
Hughes, Douglas A.
2006-04-04
A method and system are provided for determining the torque required to launch a vehicle having a hybrid drive-train that includes at least two independently operable prime movers. The method includes the steps of determining the value of at least one control parameter indicative of a vehicle operating condition, determining the torque required to launch the vehicle from the at least one determined control parameter, comparing the torque available from the prime movers to the torque required to launch the vehicle, and controlling operation of the prime movers to launch the vehicle in response to the comparing step. The system of the present invention includes a control unit configured to perform the steps of the method outlined above.
Major, Thomas W; Carey, Jason P; Nobes, David S; Heo, Giseon; Major, Paul W
2011-09-01
Control of root torque is often achieved by introducing a twist in a rectangular archwire. The purpose of this study was to investigate third-order torque on different types of self-ligated brackets by analyzing the bracket's elastic and plastic deformations in conjunction with the expressed torque at varying angles of twist. An orthodontic bracket was mounted to a load cell that measured forces and moments in all directions. The wire was twisted in the bracket via a stepper motor, controlled by custom software. Overhead images were taken by a camera through a microscope and processed by using optical correlation to measure deformation. At the maximum torquing angle of 63° with 0.019 × 0.025-in stainless steel wire, the total elastic and plastic deformation values were 0.063, 0.033, and 0.137 mm for Damon Q (Ormco, Orange, Calif), In-Ovation R (GAC, Bohemia, NY), and Speed (Strite Industries, Cambridge, Ontario, Canada), respectively. The total plastic deformation values were 0.015, 0.006, and 0.086 mm, respectively, measured at 0° of unloading. In-Ovation R had the least deformation due to torquing of the 3 investigated bracket types. Damon Q and Speed on average had approximately 2.5 and 14 times greater maximum plastic deformation, respectively, than did In-Ovation R. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
Research on EHN additive on the diesel engine combustion characteristics in plateau environment
NASA Astrophysics Data System (ADS)
Sun, Zhixin; Li, Ruoting; Wang, Xiancheng; Hu, Chuan
2017-03-01
Aiming at the combustion deterioration problem of diesel engine in plateau environment, a bench test was carried out for the effects of EHN additive on combustion characteristics of the diesel engine with intake pressure of 0.68 kPa. Test results showed that with the full load working condition of 1 400 r/min: Cylinder pressure and pressure uprising rate decreased with EHN additive added in, mechanical load on the engine could be relieved; peak value of the heat release rate decreased and its occurrence advanced, ignition delay and combustion duration were shortened; cylinder temperature and exhaust gas temperature declined, thermal load on the engine could be relieved, output torque increased while specific oil consumption decreased, and effective thermal efficiency of diesel engine increased.
Stability Study of Anthropomorphic Robot Antares under External Load Action
NASA Astrophysics Data System (ADS)
Kodyakov, A. S.; Pavlyuk, N. A.; Budkov, V. Yu; Prakapovich, R. A.
2017-01-01
The paper presents the study of the behavior of the major structural elements of the lower limbs of anthropomorphic robot Antares under the influence of different types of loads (torsion, fracture). We have determined the required values for actuators torques for motion of the robot in space. The maximum values of torques are 5 Nm and 5.2 Nm respectively, and are able to withstand the upper and lower leg structures.
Mechanical detection of electron spin resonance beyond 1 THz
DOE Office of Scientific and Technical Information (OSTI.GOV)
Takahashi, Hideyuki; Ohmichi, Eiji; Ohta, Hitoshi
2015-11-02
We report the cantilever detection of electron spin resonance (ESR) in the terahertz (THz) region. This technique mechanically detects ESR as a change in magnetic torque that acts on the cantilever. The ESR absorption of a tiny single crystal of Co Tutton salt, Co(NH{sub 4}){sub 2}(SO{sub 4}){sub 2}⋅6H{sub 2}O, was observed in frequencies of up to 1.1 THz using a backward travelling wave oscillator as a THz-wave source. This is the highest frequency of mechanical detection of ESR till date. The spectral resolution was evaluated with the ratio of the peak separation to the sum of the half-width at halfmore » maximum of two absorption peaks. The highest resolution value of 8.59 ± 0.53 was achieved at 685 GHz, while 2.47 ± 0.01 at 80 GHz. This technique will not only broaden the scope of ESR spectroscopy application but also lead to high-spectral-resolution ESR imaging.« less
Modelling grain alignment by radiative torques and hydrogen formation torques in reflection nebula
NASA Astrophysics Data System (ADS)
Hoang, Thiem; Lazarian, A.; Andersson, B.-G.
2015-04-01
Reflection nebulae - dense cores - illuminated by surrounding stars offer a unique opportunity to directly test our quantitative model of grain alignment based on radiative torques (RATs) and to explore new effects arising from additional torques. In this paper, we first perform detailed modelling of grain alignment by RATs for the IC 63 reflection nebula illuminated both by a nearby γ Cas star and the diffuse interstellar radiation field. We calculate linear polarization pλ of background stars by radiatively aligned grains and explore the variation of fractional polarization (pλ/AV) with visual extinction AV across the cloud. Our results show that the variation of pV/AV versus AV from the dayside of IC 63 to its centre can be represented by a power law (p_V/A_V∝ A_V^{η }) with different slopes depending on AV. We find a shallow slope η ˜ -0.1 for AV < 3 and a very steep slope η ˜ -2 for AV > 4. We then consider the effects of additional torques due to H2 formation and model grain alignment by joint action of RATs and H2 torques. We find that pV/AV tends to increase with an increasing magnitude of H2 torques. In particular, the theoretical predictions obtained for pV/AV and peak wavelength λmax in this case show an improved agreement with the observational data. Our results reinforce the predictive power of the RAT alignment mechanism in a broad range of environmental conditions and show the effect of pinwheel torques in environments with efficient H2 formation. Physical parameters involved in H2 formation may be constrained using detailed modelling of grain alignment combined with observational data. In addition, we discuss implications of our modelling for interpreting latest observational data by Planck and other ground-based instruments.
Ateş, Filiz; Hug, François; Bouillard, Killian; Jubeau, Marc; Frappart, Thomas; Couade, Mathieu; Bercoff, Jeremy; Nordez, Antoine
2015-08-01
Muscle shear elastic modulus is linearly related to muscle torque during low-level contractions (<60% of Maximal Voluntary Contraction, MVC). This measurement can therefore be used to estimate changes in individual muscle force. However, it is not known if this relationship remains valid for higher intensities. The aim of this study was to determine: (i) the relationship between muscle shear elastic modulus and muscle torque over the entire range of isometric contraction and (ii) the influence of the size of the region of interest (ROI) used to average the shear modulus value. Ten healthy males performed two incremental isometric little finger abductions. The joint torque produced by Abductor Digiti Minimi was considered as an index of muscle torque and elastic modulus. A high coefficient of determination (R(2)) (range: 0.86-0.98) indicated that the relationship between elastic modulus and torque can be accurately modeled by a linear regression over the entire range (0% to 100% of MVC). The changes in shear elastic modulus as a function of torque were highly repeatable. Lower R(2) values (0.89±0.13 for 1/16 of ROI) and significantly increased absolute errors were observed when the shear elastic modulus was averaged over smaller ROI, half, 1/4 and 1/16 of the full ROI) than the full ROI (mean size: 1.18±0.24cm(2)). It suggests that the ROI should be as large as possible for accurate measurement of muscle shear modulus. Copyright © 2015 Elsevier Ltd. All rights reserved.
Effect of screw torque level on cortical bone pullout strength.
Cleek, Tammy M; Reynolds, Karen J; Hearn, Trevor C
2007-02-01
The objectives of this study were 2-fold: (1) to perform detailed analysis of cortical screw tightening stiffness during automated insertion, and (2) to determine the effect of 3 torque levels on the holding strength of the bone surrounding the screw threads as assessed by screw pullout. Ten pairs of ovine tibiae were used with 3 test sites spaced 20 mm apart centered along the shaft. One side of each pair was used for measuring ultimate failure torque (Tmax). These Tmax and bone-density values were used to predict Tmax at contralateral tibia sites. Screws were inserted and tightened to 50%, 70%, and 90% of predicted Tmax at the contralateral sites to encompass the average clinical level of torque (86% Tmax). Pullout tests were performed and maximum force values were normalized by cortical thickness. Torque to failure tests indicated tightening to 86% Tmax occurs after yield and leads to an average 51% loss in stiffness. Normalized pullout strength for screws tightened to 50% Tmax, 70% Tmax, and 90% Tmax were 2525 +/- 244, 2707 +/- 280, and 2344 +/- 346 N, respectively, with a significant difference between 70% Tmax and 90% Tmax groups (P < 0.05). Within the limitations of our study involving the testing of 1 type of screw purchase in ovine tibiae, results demonstrate that clinical levels of lag screw tightening (86% Tmax) are past the yield point of bone. Tightening to these high torque levels can cause damage leading to compromised holding strength. Further research is still required to establish the appropriate level of torque required for achieving optimal fracture fixation and healing.
Fabrication of nanotweezers and their remote actuation by magnetic fields.
Iss, Cécile; Ortiz, Guillermo; Truong, Alain; Hou, Yanxia; Livache, Thierry; Calemczuk, Roberto; Sabon, Philippe; Gautier, Eric; Auffret, Stéphane; Buda-Prejbeanu, Liliana D; Strelkov, Nikita; Joisten, Hélène; Dieny, Bernard
2017-03-27
A new kind of nanodevice that acts like tweezers through remote actuation by an external magnetic field is designed. Such device is meant to mechanically grab micrometric objects. The nanotweezers are built by using a top-down approach and are made of two parallelepipedic microelements, at least one of them being magnetic, bound by a flexible nanohinge. The presence of an external magnetic field induces a torque on the magnetic elements that competes with the elastic torque provided by the nanohinge. A model is established in order to evaluate the values of the balanced torques as a function of the tweezers opening angles. The results of the calculations are confronted to the expected values and validate the overall working principle of the magnetic nanotweezers.
NASA Astrophysics Data System (ADS)
Wang, Lin-Jie; Cheng, Tan; Zhi-Li, Li; Hui-juan, Wang; Wen-juan, Chen; Jianfeng, Zhang; Desheng, Wang; Dongbin, Niu; Qi, Zhao; Chengjia, Yang; Yanqing, Wang
High intensity interval training (HIIT) has been demonstrated to improve performance in a relatively short training period. But the difference between high intensity interval training and moderate intensity interval training (MIIT) in simulated weightlessness still has not been well studied. This study sought to characterize the difference between 6 weeks high intensity interval training and moderate intensity interval training under reduced weight (RW) gait training device and zero-gravity locomotion system (ZLS). Twenty-three subjects (14M/4F, 32.5±4.5 years) volunteered to participate. They were divided into three groups, that were MITT (alternating 2 min at 40% VO _{2} peak and 2 min at 60% VO _{2} peak for 30min, five days per week) RW group (n=8), HITT (alternating 2 min at 40% VO _{2} peak and 2 min at 90% VO _{2} peak for 30min, three days per week) RW group (n=8) and HITT ZLS group (n=7). The Z-axis load used in RW group was 80% body weight (BW) and in ZLS was 100% BW. Cardiopulmonary function was measured before, after 4-week training and after 6-week training. Isokinetic knee extension-flexion test at 60(°) deg/s and 180(°) deg/s were performed before and after the 6-week training, and isometric knee extension-flexion test at 180(°) deg/s was also examined at the same time. It was found that the VO _{2} peaks, metabolic equivalent (MET), Speedmax and respiratory exchange ratio (RER) were significantly increased after 4 and 6-week training in all three groups and no significant group difference were detected. The peak torque at 60(°) deg/s for right knee flexion were significantly increased after 6 week-training in all three groups, and only in HITT RW group the total power at 60(°) deg/s for right knee flexion enhanced. The total power and average power at 60(°) deg/s for right knee extension decreased significantly after 6-week training in all three groups. The peak torque at 60(°) deg/s for right knee extension in MIIT RW group was significantly higher than that in HIIT ZLS group. The maximum average peak torque for isometric left knee contraction was enhanced after 6-week training in all three groups. It was suggested that HITT can be used in weightlessness to maintain the cardiopulmonary function in a relatively short training period, but the effect of HIIT on the maintenance of muscle function still need further study. (Supported by State Key Laboratory Grant NO. SMFA10A04 and The Twelfth Five Year Plan of Medical and Health Research Grant NO. BWS11J055)
Regalin, Alexandre; Bhering, Claudia Lopes Brilhante; Alessandretti, Rodrigo; Spazzin, Aloisio Oro
2015-01-01
PURPOSE The purpose of this study was to evaluate the influence of tightening technique and the screw coating on the loosening torque of screws used for Universal Abutment fixation after cyclic loading. MATERIALS AND METHODS Forty implants (Titamax Ti Cortical, HE, Neodent) (n=10) were submerged in acrylic resin and four tightening techniques for Universal Abutment fixation were evaluated: A - torque with 32 Ncm (control); B - torque with 32 Ncm holding the torque meter for 20 seconds; C - torque with 32 Ncm and retorque after 10 minutes; D - torque (32 Ncm) holding the torque meter for 20 seconds and retorque after 10 minutes as initially. Samples were divided into subgroups according to the screw used: conventional titanium screw or diamond like carbon-coated (DLC) screw. Metallic crowns were fabricated for each abutment. Samples were submitted to cyclic loading at 106 cycles and 130 N of force. Data were analyzed by two-way ANOVA and Tukey's test (5%). RESULTS The tightening technique did not show significant influence on the loosening torque of screws (P=.509). Conventional titanium screws showed significant higher loosening torque values than DLC (P=.000). CONCLUSION The use of conventional titanium screw is more important than the tightening techniques employed in this study to provide long-term stability to Universal Abutment screws. PMID:26576253
Péter, Annamária; Hegyi, András; Stenroth, Lauri; Finni, Taija; Cronin, Neil J
2015-09-18
Large forces are generated under the big toe in the push-off phase of walking. The largest flexor muscle of the big toe is the flexor hallucis longus (FHL), which likely contributes substantially to these forces. This study examined FHL function at different levels of isometric plantarflexion torque and in the push-off phase at different speeds of walking. FHL and calf muscle activity were measured with surface EMG and plantar pressure was recorded with pressure insoles. FHL activity was compared to the activity of the calf muscles. Force and impulse values were calculated under the big toe, and were compared to the entire pressed area of the insole to determine the relative contribution of big toe flexion forces to the ground reaction force. FHL activity increased with increasing plantarflexion torque level (F=2.8, P=0.024) and with increasing walking speed (F=11.608, P<0.001). No differences were observed in the relative contribution of the force under the big toe to the entire sole between different plantarflexion torque levels (F=0.836, P=0.529). On the contrary, in the push-off phase of walking, peak force under the big toe increased at a higher rate than force under the other areas of the plantar surface (F=3.801, P=0.018), implying a greater relative contribution to total force at faster speeds. Moreover, substantial differences were found between isometric plantarflexion and walking concerning FHL activity relative to that of the calf muscles, highlighting the task-dependant behaviour of FHL. Copyright © 2015 Elsevier Ltd. All rights reserved.
Xu, M T; Sun, S; Zhang, L; Xu, F; Du, S L; Zhang, X D; Wang, D W
2016-01-01
Transforming growth factor beta 1 (TGF-β1) and bone morphogenetic protein-2 (BMP-2) are important regulators of bone repair and regeneration. In this study, we examined whether TGF-β1 and BMP-2 expressions were delayed during bone healing in type 1 diabetes mellitus. Tibial fractures were created in 95 diabetic and 95 control adult male Wistar rats of 10 weeks of age. At 1, 2, 3, 4, and 5 weeks after fracture induction, five rats were sacrificed from each group. The expressions of TGF-β1 and BMP2 in the fractured tibias were measured by immunohistochemistry and quantitative reverse-transcription polymerase chain reaction, weekly for the first 5 weeks post-fracture. Mechanical parameters (bending rigidity, torsional rigidity, destruction torque) of the healing bones were also assessed at 3, 4, and 5 weeks post-fracture, after the rats were sacrificed. The bending rigidity, torsional rigidity and destruction torque of the two groups increased continuously during the healing process. The diabetes group had lower mean values for bending rigidity, torsional rigidity and destruction torque compared with the control group (P<0.05). TGF-β1 and BMP-2 expression were significantly lower (P<0.05) in the control group than in the diabetes group at postoperative weeks 1, 2, and 3. Peak levels of TGF-β1 and BMP-2 expression were delayed by 1 week in the diabetes group compared with the control group. Our results demonstrate that there was a delayed recovery in the biomechanical function of the fractured bones in diabetic rats. This delay may be associated with a delayed expression of the growth factors TGF-β1 and BMP-2.
Prevailing Torque Locking Feature in Threaded Fasteners Using Anaerobic Adhesive
NASA Technical Reports Server (NTRS)
Hernandez, Alan; Hess, Daniel P.
2016-01-01
This paper presents results from tests to assess the use of anaerobic adhesive for providing a prevailing torque locking feature in threaded fasteners. Test procedures are developed and tests are performed on three fastener materials, four anaerobic adhesives, and both unseated assembly conditions. Five to ten samples are tested for each combination. Tests for initial use, reuse without additional adhesive, and reuse with additional adhesive are performed for all samples. A 48-hour cure time was used for all initial use and reuse tests. Test data are presented as removal torque versus removal angle with the specification required prevailing torque range added for performance assessment. Percent specification pass rates for the all combinations of fastener material, adhesive, and assembly condition are tabulated and reveal use of anaerobic adhesive as a prevailing torque locking feature is viable. Although not every possible fastener material and anaerobic adhesive combination provides prevailing torque values within specification, any combination can be assessed using the test procedures presented. Reuse without additional anaerobic adhesive generally provides some prevailing torque, and in some cases within specification. Reuse with additional adhesive often provides comparable removal torque data as in initial use.
Katalinic, Andrej; Trinajstic Zrinski, Magda; Roksandic Vrancic, Zlatka; Spalj, Stjepan
2017-02-01
The study focused on the influence of screwdriver design in combination with and without predrilling a pilot hole of inner implant diameter on insertion torque of orthodontic mini-implants, controlling for cortical thickness and vertical insertion force as cofactors. One hundred twenty mini-implants (Forestadent) of 1.7 mm in diameter and 6 and 8 mm in length were manually inserted into 120 swine rib bone samples. Maximal insertion torque as a measure of primary stability and vertical force were measured. The study included procedures with and without pilot hole and different screwdriver handles and shaft length and 2 implant lengths. Design of manual screwdriver does not modify insertion torque to a significant extent. In multiple linear regression model, significant predictors of insertion torque are thicker cortical bone (explaining 16.6% of variability), higher vertical force at maximal torque (13.5%), 6-mm implant length (2.5%), and the presence of pilot hole (2.3%). Handle type and shaft length of manual screwdriver do not significantly influence insertion torque, whereas predrilling a pilot hole has low impact on torque values of manually inserted self-drilling orthodontic mini-implants.
Influence of Screw Length and Bone Thickness on the Stability of Temporary Implants
Fernandes, Daniel Jogaib; Elias, Carlos Nelson; Ruellas, Antônio Carlos de Oliveira
2015-01-01
The purpose of this work was to study the influence of screw length and bone thickness on the stability of temporary implants. A total of 96 self-drilling temporary screws with two different lengths were inserted into polyurethane blocks (n = 66), bovine femurs (n = 18) and rabbit tibia (n = 12) with different cortical thicknesses (1 to 8 mm). Screws insertion in polyurethane blocks was assisted by a universal testing machine, torque peaks were collected by a digital torquemeter and bone thickness was monitored by micro-CT. The results showed that the insertion torque was significantly increased with the thickness of cortical bone from polyurethane (p < 0.0001), bovine (p = 0.0035) and rabbit (p < 0.05) sources. Cancellous bone improved significantly the mechanical implant stability. Insertion torque and insertion strength was successfully moduled by equations, based on the cortical/cancellous bone behavior. Based on the results, insertion torque and bone strength can be estimate in order to prevent failure of the cortical layer during temporary screw placement. The stability provided by a cortical thickness of 2 or 1 mm coupled to cancellous bone was deemed sufficient for temporary implants stability. PMID:28793582
Atmospheric Torques on the Solid Earth and Oceans Based on the GEOS-1 General Circulation Model
NASA Technical Reports Server (NTRS)
Sanchez, Braulio V.; Au, Andrew Y.
1998-01-01
The GEOS-1 general circulation model has been used to compute atmospheric torques on the oceans and solid Earth for the period 1980-1995. The time series for the various torque components have been analyzed by means of Fourier transform techniques. It was determined that the wind stress torque over land is more powerful than the wind stress torque over water by 55%, 42%, and 80% for the x, y, and z components respectively. This is mainly the result of power in the high frequency range. The pressure torques due to polar flattening, equatorial ellipticity, marine geoid, and continental orography were computed. The orographic or "mountain torque" components are more powerful than their wind stress counterparts (land plus ocean) by 231% (x), 191% (y), and 77% (z). The marine pressure torques due to geoidal undulations are much smaller than the orographic ones, as expected. They are only 3% (x), 4% (y), and 5% (z) of the corresponding mountain torques. The geoidal pressure torques are approximately equal in magnitude to those produced by the equatorial ellipticity of the Earth. The pressure torque due to polar flattening makes the largest contributions to the atmospheric torque budget. It has no zonal component, only equatorial ones. Most of the power of the latter, between 68% and 69%, is found in modes with periods under 15 days. The single most powerful mode has a period of 361 days. The gravitational torque ranks second in power only to the polar flattening pressure torque. Unlike the former, it does produce a zonal component, albeit much smaller (1%) than the equatorial ones. The gravitational and pressure torques have opposite signs, therefore, the gravitational torque nullifies 42% of the total pressure torque. Zonally, however, the gravitational torque amounts to only 6% of the total pressure torque. The power budget for the total atmospheric torque yields 7595 and 7120 Hadleys for the equatorial components and 966 Hadleys for the zonal. The x-component exhibits a large mean value (1811 H), mainly the result of polar flattening pressure torque acting on the ocean surfaces. Atmospheric torque modes with periods of 408, 440, and 476 days appear in the spectrum of the equatorial components.
Atmospheric Torques on the Solid Earth and Oceans Based on the GEOS-1 General Circulation Model
NASA Technical Reports Server (NTRS)
Sanchez, Braulio
1999-01-01
The GEOS-1 general circulation model has been used to compute atmospheric torques on the oceans and solid Earth for the period 1980-1995. The time series for the various torque components have been analyzed by means of Fourier transform techniques. It was determined that the wind stress torque over land is more powerful than the wind stress torque over water by 55\\%, 42\\%, and 80\\t for the x, y, and z components respectively. This is mainly the result of power in the high frequency range. The pressure torques due to polar flattening, equatorial ellipticity, marine geoid, and continental orography were computed. The orographic or "mountain torque" components are more powerful than their wind stress counterparts (land plus ocean) by 231\\% (x), 191\\% (y), and 77\\% (z). The marine pressure torques due to geoidal undulations are much smaller than the orographic ones, as expected. They are only 3\\% (x), 4\\% (y), and 5\\% (z) of the corresponding mountain torques. The geoidal pressure torques are approximately equal in magnitude to those produced by the equatorial ellipticity of the Earth. The pressure torque due to polar flattening makes the largest contributions to the atmospheric'torque budget. It has no zonal component, only equatorial ones. Most of the power of the latter, between 68\\% and 69 %, is found in modes with periods under 15 days. The single most powerful mode has a period of 361 days. The gravitational torque ranks second in power only to the polar flattening pressure torque. Unlike the former, it does produce a zonal component, albeit much smaller (1\\ ) than the equatorial ones. The gravitational and pressure torques have opposite signs, therefore, the gravitational torque nullifies 42\\% of the total pressure torque. Zonally, however, the gravitational torque amounts to only 6\\% of the total pressure torque. The power budget for the total atmospheric torque yields 7595 and 7120 Hadleys for the equatorial components and 966 Hadleys for the zonal. The x-component exhibits a large mean value (1811 H), mainly the result of polar flattening pressure torque acting on the ocean surfaces. Atmospheric torque modes with periods of 408, 440, and 476 days appear in the spectrum of the equatorial components.
Thompson, Christopher K; Lewek, Michael D; Jayaraman, Arun; Hornby, T George
2011-01-01
Abstract Despite greater muscle fatigue in individuals with spinal cord injury (SCI) when compared to neurologically intact subjects using neuromuscular electrical stimulation (NMES) protocols, few studies have investigated the extent of volitional fatigue in motor incomplete SCI. Using an established protocol of 20 repeated, intermittent, maximal volitional effort (MVE) contractions, we previously demonstrated that subjects with incomplete SCI unexpectedly demonstrated a 15% increase in peak knee extensor torques within the first five MVEs with minimal evidence of fatigue after 20 contraction. In the present study, we investigated potential segmental mechanisms underlying this supramaximal torque generation. Changes in twitch properties and maximum compound muscle action potentials (M-waves) were assessed prior to and following one, three and five MVEs, revealing a significant 17% increase only in maximum twitch torques after a single MVE. Despite this post-activation potentiation of the muscle, use of conventional NMES protocols to elicit repeated muscular contractions resulted in a significant decrease in evoked torque generation, suggesting limited the muscular contributions to the observed phenomenon. To evaluate potential central mechanisms underlying the augmented torques, non-linear responses to wide-pulse width (1 ms), low-intensity, variable-frequency (25–100 Hz) NMES were also tested prior to and following repeated MVEs. When variable-frequency NMES was applied following the repeated MVEs, augmented and prolonged torques were observed and accompanied by sustained quadriceps electromyographic activity often lasting >2s after stimulus termination. Such data suggest a potential contribution of elevated spinal excitability to the reserve in volitional force generation in incomplete SCI. PMID:21610138
Mathematical model of the solar radiation force and torques acting on the components of a spacecraft
NASA Technical Reports Server (NTRS)
Georgevic, R. M.
1971-01-01
General expressions for the solar radiation force and torques are derived in the vectorial form for any given reflecting surface, provided that the reflecting characteristics of the surface, as well as the value of the solar constant, are known. An appropriate choice of a spacecraft-fixed frame of reference leads to relatively simple expressions for the solar radiation forces and torques in terms of the functions of the sun-spacecraft-earth angle.
Sardarian, Ahmadreza; Danaei, Shahla Momeni; Shahidi, Shoaleh; Boushehri, Sahar Ghodsi; Geramy, Allahyar
2014-01-01
The ideal built-in tip and torque values of the straight wire appliance reduce the need for wire bending and hence reduce chair time. The vertical position of the bracket on the tooth surface can alter the torque exerted on the tooth. This is a result of the altered surface curvature observed at each vertical position. To further clarify the role of vertical bracket positioning on the applied torque and the resultant stresses in the periodontal ligament (PDL), we designed a mandibular first premolar using finite element modeling. Cone beam computed tomography of 52 patients (83 lower first premolars) was selected to be included in the study. Curvature was measured for points along the labial surface with increasing distances (0.5 mm increments) from the cusp tip by calculating the angle between tangents drawn from these points and the axis joining the cusp tip and the root apex. The mean values for each distance were calculated, and a finite element model was designed incorporating these mean values. The resultant stress and hydrostatic pressure in the PDL were calculated using finite element analysis. The labial surface of the mandibular first premolar demonstrated a 26.39° change from 2.5 to 6 mm from the cusp tip. The maximum Von-Mises stress and hydrostatic pressure in the PDL were observed at the root apex for all of the bracket positions, and these values demonstrated, respectively, a change of up to 0.059 and 0.186 MPa between two successive points. It can be concluded that the variation in the vertical position of the bracket can have an important effect on the torque and subsequently on the stresses and pressures in the PDL.
Assessment of dimensional accuracy of preadjusted metal injection molding orthodontic brackets.
Alavi, Shiva; Tajmirriahi, Farnaz
2016-09-01
the aim of this study is to evaluate the dimensional accuracy of McLaughlin, Bennett, and Trevisi (MBT) brackets manufactured by two different companies (American Orthodontics and Ortho Organizers) and determine variations in incorporation of values in relation to tip and torque in these products. In the present analytical/descriptive study, 64 maxillary right central brackets manufactured by two companies (American Orthodontics and Ortho Organizers) were selected randomly and evaluated for the accuracy of the values in relation to torque and angulation presented by the manufacturers. They were placed in a video measuring machine using special revolvers under them and were positioned in a manner so that the light beams would be directed on the floor of the slot without the slot walls being seen. Then, the software program of the same machine was used to determine the values of each bracket type. The means of measurements were determined for each sample and were analyzed with independent t -test and one-sample t -test. Based on the confidence interval, it can be concluded that at 95% probability, the means of tip angles of maxillary right central brackets of these two brands were 4.1-4.3° and the torque angles were 16.39-16.72°. The tips in these samples were at a range of 3.33-4.98°, and the torque was at a range of 15.22-18.48°. In the present study, there were no significant differences in the angulation incorporated into the brackets from the two companies; however, they were significantly different from the tiP values for the MBT prescription. In relation to torque, there was a significant difference between the American Orthodontic brackets exhibited significant differences with the reported 17°, too.
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.; Bernauer, E. M.; Ertl, A. C.; Bulbulian, R.; Bond, M.
1994-01-01
The purpose of our study was to determine if an intensive, intermittent, isokinetic, lower extremity exercise training program would attenuate or eliminate the decrease of muscular strength and endurance during prolonged bed rest (BR). The 19 male subjects (36 +/- 1 yr, 178 +/- 2 cm, 76.5 +/- 1.7 kg) were allocated into a no exercise (NOE) training group (N = 5), an isotonic (lower extremity cycle ergometer) exercise (ITE) training group (N = 7), and an isokinetic (isokinetic knee flexion-extension) exercise (IKE) training group (N = 7). Peak knee (flexion and extension) and shoulder (abduction-adduction) functions were measured weekly in all groups with one 5-repetition set. After BR, average knee extension total work decreased by 16% with NOE, increased by 27% with IKE, and was unchanged with ITE. Average knee flexion total work and peak torque (strength) responses were unchanged in all groups. Force production increased by 20% with IKE and was unchanged with NOE and ITE. Shoulder total work was unchanged in all groups, while gross average peak torque increased by 27% with ITE and by 22% with IKE, and was unchanged with NOE. Thus, while ITE training can maintain some isokinetic functions during BR, maximal intermittent IKE training can increase other functions above pre-BR control levels.
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.; Bernauer, E. M.; Ertl, A. C.; Bond, M.; Bulbulian, R.
1994-01-01
The purpose of our study was to determine if an intensive, intermittent, isokinetic, lower extremity exercise training program would attenuate or eliminate the decrease of muscular strength and endurance during prolonged bed rest (BR). The 19 male subjects (36 +/- 1 yr, 178 +/- 2 cm, 76.5 +/- 1.7 kg) were allocated into a no exercise (NOE) training group (N = 5), an isotonic (lower extremity cycle orgometer) exercise (ITE) training group (N = 7), and an isokinetic (isokinetic knee flexion-extension) exercise (IKE) training group (N = 7). Peak knee (flexion and extension) and shoulder (abduction-adduction) functions were measured weekly in all groups with one 5-repetition set. After BR, average knee extension total work decreased by 16% with NOE, increased by 27% with IKE, and was unchanged with ITE. Average knee flexion total work and peak torque (strength) responses were unchanged in all groups. Force production increased by 20% with IKE and was unchanged with NOE and ITE. Shoulder total work was unchanged in all groups, while gross average peak torque increased by 27% with ITE and by 22% with IKE, and was unchanged with NOE. Thus, while ITE training can maintain some isokinetic functions during BR, maximal intermittent IKE training can increase other functions above pre-BR control levels.
Transport of active ellipsoidal particles in ratchet potentials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ai, Bao-Quan, E-mail: aibq@scnu.edu.cn; Wu, Jian-Chun
2014-03-07
Rectified transport of active ellipsoidal particles is numerically investigated in a two-dimensional asymmetric potential. The out-of-equilibrium condition for the active particle is an intrinsic property, which can break thermodynamical equilibrium and induce the directed transport. It is found that the perfect sphere particle can facilitate the rectification, while the needlelike particle destroys the directed transport. There exist optimized values of the parameters (the self-propelled velocity, the torque acting on the body) at which the average velocity takes its maximal value. For the ellipsoidal particle with not large asymmetric parameter, the average velocity decreases with increasing the rotational diffusion rate, whilemore » for the needlelike particle (very large asymmetric parameter), the average velocity is a peaked function of the rotational diffusion rate. By introducing a finite load, particles with different shapes (or different self-propelled velocities) will move to the opposite directions, which is able to separate particles of different shapes (or different self-propelled velocities)« less
Stüker, Rafael Augusto; Teixeira, Eduardo Rolim; Beck, João Carlos Pinheiro; da Costa, Nilza Pereira
2008-01-01
Several authors still consider the mechanical problems of fracture and component loosening as the main causes of failure of implant-supported restorations. The purpose of this in vitro study was to compare the preload of three types of screw for transmucosal abutment attachment used in single implant-supported prosthesis through strain gauge and removal torque measurements. Three external hex fixtures were used, and each received a transmucosal abutment (Cera One®), which was fixed to the implant with its respective screw: Group A- gold screw, Group B- titanium screw and Group C- surface-treated titanium screw (Ti-Tite®). Ten screws of each type were attached applying a 30.07±0.28 Ncm torque force and maintained in position for 5 minutes. After this, the preload values were measured using strain gauges and a measurement cell. Gold screws presented higher preload values (131.72±8.98 N), followed by surface-treated titanium screws (97.78±4.68 N) and titanium screws (37.03±5.69 N). ANOVA (p<0.05) and Tukey's test (p<0.05) were applied. Statistically significant differences were found among the groups for both preload and removal torque values. In conclusion, gold screws may be indicated to achieve superior longevity of the abutment-implant connection and, consequently, prosthetic restoration due to greater preload values yielded. PMID:19089290
Influence of spore moisture content on the dry-heat resistance of Bacillus subtilis var. niger.
Angelotti, R; Maryanski, J H; Butler, T F; Peeler, J T; Campbell, J E
1968-05-01
The dry-heat resistance of Bacillus subtilis var. niger spores located in or on various materials was determined as D and z values in the range of 105 through 160 C. The systems tested included spores located on steel and paper strips, spores located between stainless-steel washers mated together under 150 inch-lb and 12 inch-lb of torque, and spores encapsulated in methylmethacrylate and epoxy plastics. D values for a given temperature varied with the test system. High D values were observed for the systems in which spores were encapsulated or under heavy torque, whereas lower D values were observed for the steel and paper strip systems and the lightly torqued system. Similar z values were obtained for the plastic and steel strip systems (z(D) = 21 C), but an unusually low z for spores on paper (z(D) = 12.9 C) and an unusually high z for spores on steel washers mated at 150 inch-lb of torque (z(D) = 32 C) were observed. The effect of spore moisture content on the D value of spores encapsulated in water-impermeable plastic was determined, and maximal resistance was observed for spores with a water activity (a(w)) of 0.2 to 0.4. Significantly decreased D values were observed for spores with moisture contents below a(w) 0.2 or above a(w) 0.4. The data indicate that the important factors to be considered when measuring the dry heat resistance of spores are (i) the initial moisture content of the spore, (ii) the rate of spore desiccation during heating, (iii) the water retention capacity of the material in or on which spores are located, and (iv) the relative humidity of the system at the test temperature.
Eagle, Shawn R.; Connaboy, Chris; Nindl, Bradley C.; Allison, Katelyn F.
2018-01-01
Background: Musculoskeletal injuries to the extremities are a primary concern for the United States (US) military. One possible injury risk factor in this population is side-to-side strength imbalance. Purpose: To examine the odds of reporting a previous shoulder injury in US Marine Corps Ground Combat Element Integrated Task Force volunteers based on side-to-side strength differences in isokinetic shoulder strength. Study Design: Cohort study; Level of evidence, 3. Methods: Male (n = 219) and female (n = 91) Marines were included in this analysis. Peak torque values from 5 shoulder internal/external rotation repetitions were averaged and normalized to body weight. The difference in side-to-side strength measurements was calculated as the absolute value of the limb difference divided by the mean peak torque of the dominant limb. Participants were placed into groups based on the magnitude of these differences: <10%, 10% to 20%, and >20%. Odds ratios (ORs) and 95% CIs were calculated. Results: When separated by sex, 13.2% of men reported an injury, while 5.5% of women reported an injury. Female Marines with >20% internal rotation side-to-side strength differences demonstrated increased odds of reporting a previous shoulder injury compared with female Marines with <10% strength differences (OR, 15.4; 95% CI, 1.4-167.2; P = .03 ) and female Marines with 10% to 20% strength differences (OR, 13.9; 95% CI, 1.3-151.2; P = .04). No significant ORs were demonstrated in male Marines. Conclusion: Marines with larger magnitude internal rotation strength differences demonstrated increased odds of reporting a previous shoulder injury compared with those with lesser magnitude differences. Additionally, female sex appears to drastically affect the increased odds of reporting shoulder injuries (OR, 13.9-15.4) with larger magnitude differences (ie, >20%) compared with those with lesser magnitude differences (ie, <10% and 10%-20%). The retrospective cohort design of this study cannot delineate cause and effect but establishes a relationship between female Marines and greater odds of larger magnitude strength differences after returning from an injury. PMID:29497623
Baroni, Bruno M; Pompermayer, Marcelo G; Cini, Anelize; Peruzzolo, Amanda S; Radaelli, Régis; Brusco, Clarissa M; Pinto, Ronei S
2017-08-01
Baroni, BM, Pompermayer, MG, Cini, A, Peruzzolo, AS, Radaelli, R, Brusco, CM, and Pinto, RS. Full range of motion induces greater muscle damage than partial range of motion in elbow flexion exercise with free weights. J Strength Cond Res 31(8): 2223-2230, 2017-Load and range of motion (ROM) applied in resistance training (RT) affect the muscle damage magnitude and the recovery time-course. Because exercises performed with partial ROM allow a higher load compared with those with full ROM, this study investigated the acute effect of a traditional RT exercise using full ROM or partial ROM on muscle damage markers. Fourteen healthy men performed 4 sets of 10 concentric-eccentric repetitions of unilateral elbow flexion on the Scott bench. Arms were randomly assigned to partial-ROM (50-100°) and full-ROM (0-130°) conditions, and load was determined as 80% of 1 repetition maximum (1RM) in the full- and partial-ROM tests. Muscle damage markers were assessed preexercise, immediately, and 24, 48, and 72 hours after exercise. Primary outcomes were peak torque, muscle soreness during palpation and elbow extension, arm circumference, and joint ROM. The load lifted in the partial-ROM condition (1RM = 19.1 ± 3.0 kg) was 40 ± 18% higher compared with the full-ROM condition (1RM = 13.7 ± 2.2 kg). Seventy-two hours after exercise, the full-ROM condition led to significant higher soreness sensation during elbow extension (1.3-4.1 cm vs. 1.0-1.9 cm) and smaller ROM values (97.5-106.1° vs. 103.6-115.7°). Peak torque, soreness from palpation, and arm circumference were statistically similar between conditions, although mean values in all time points of these outcomes have suggested more expressive muscle damage for the full-ROM condition. In conclusion, elbow flexion exercise with full ROM seems to induce greater muscle damage than partial-ROM exercises, even though higher absolute load was achieved with partial ROM.
Eagle, Shawn R; Connaboy, Chris; Nindl, Bradley C; Allison, Katelyn F
2018-02-01
Musculoskeletal injuries to the extremities are a primary concern for the United States (US) military. One possible injury risk factor in this population is side-to-side strength imbalance. To examine the odds of reporting a previous shoulder injury in US Marine Corps Ground Combat Element Integrated Task Force volunteers based on side-to-side strength differences in isokinetic shoulder strength. Cohort study; Level of evidence, 3. Male (n = 219) and female (n = 91) Marines were included in this analysis. Peak torque values from 5 shoulder internal/external rotation repetitions were averaged and normalized to body weight. The difference in side-to-side strength measurements was calculated as the absolute value of the limb difference divided by the mean peak torque of the dominant limb. Participants were placed into groups based on the magnitude of these differences: <10%, 10% to 20%, and >20%. Odds ratios (ORs) and 95% CIs were calculated. When separated by sex, 13.2% of men reported an injury, while 5.5% of women reported an injury. Female Marines with >20% internal rotation side-to-side strength differences demonstrated increased odds of reporting a previous shoulder injury compared with female Marines with <10% strength differences (OR, 15.4; 95% CI, 1.4-167.2; P = .03 ) and female Marines with 10% to 20% strength differences (OR, 13.9; 95% CI, 1.3-151.2; P = .04). No significant ORs were demonstrated in male Marines. Marines with larger magnitude internal rotation strength differences demonstrated increased odds of reporting a previous shoulder injury compared with those with lesser magnitude differences. Additionally, female sex appears to drastically affect the increased odds of reporting shoulder injuries (OR, 13.9-15.4) with larger magnitude differences (ie, >20%) compared with those with lesser magnitude differences (ie, <10% and 10%-20%). The retrospective cohort design of this study cannot delineate cause and effect but establishes a relationship between female Marines and greater odds of larger magnitude strength differences after returning from an injury.
Results and Analysis from Space Suit Joint Torque Testing
NASA Technical Reports Server (NTRS)
Matty, Jennifer
2010-01-01
A space suit's mobility is critical to an astronaut's ability to perform work efficiently. As mobility increases, the astronaut can perform tasks for longer durations with less fatigue. Mobility can be broken down into two parts: range of motion (ROM) and torque. These two measurements describe how the suit moves and how much force it takes to move. Two methods were chosen to define mobility requirements for the Constellation Space Suit Element (CSSE). One method focuses on range of motion and the second method centers on joint torque. A joint torque test was conducted to determine a baseline for current advanced space suit joint torques. This test utilized the following space suits: Extravehicular Mobility Unit (EMU), Advanced Crew Escape Suit (ACES), I-Suit, D-Suit, Enhanced Mobility (EM)- ACES, and Mark III (MK-III). Data was collected data from 16 different joint movements of each suit. The results were then reviewed and CSSE joint torque requirement values were selected. The focus of this paper is to discuss trends observed during data analysis.
30 CFR 7.308 - Lockwasher equivalency test.
Code of Federal Regulations, 2014 CFR
2014-07-01
... hole and continuously and uniformly tightened at a speed not to exceed 30 rpm until the fastening's... cycles. (b) Acceptable performance. The minimum torque value required to start removal of the fastening from the installed position (minimum breakway torque) for any cycle of any test sample shall be greater...
30 CFR 7.308 - Lockwasher equivalency test.
Code of Federal Regulations, 2011 CFR
2011-07-01
... hole and continuously and uniformly tightened at a speed not to exceed 30 rpm until the fastening's... cycles. (b) Acceptable performance. The minimum torque value required to start removal of the fastening from the installed position (minimum breakway torque) for any cycle of any test sample shall be greater...
30 CFR 7.308 - Lockwasher equivalency test.
Code of Federal Regulations, 2013 CFR
2013-07-01
... hole and continuously and uniformly tightened at a speed not to exceed 30 rpm until the fastening's... cycles. (b) Acceptable performance. The minimum torque value required to start removal of the fastening from the installed position (minimum breakway torque) for any cycle of any test sample shall be greater...
30 CFR 7.308 - Lockwasher equivalency test.
Code of Federal Regulations, 2012 CFR
2012-07-01
... hole and continuously and uniformly tightened at a speed not to exceed 30 rpm until the fastening's... cycles. (b) Acceptable performance. The minimum torque value required to start removal of the fastening from the installed position (minimum breakway torque) for any cycle of any test sample shall be greater...
30 CFR 7.308 - Lockwasher equivalency test.
Code of Federal Regulations, 2010 CFR
2010-07-01
... hole and continuously and uniformly tightened at a speed not to exceed 30 rpm until the fastening's... cycles. (b) Acceptable performance. The minimum torque value required to start removal of the fastening from the installed position (minimum breakway torque) for any cycle of any test sample shall be greater...
Effect of geometry and operating conditions on spur gear system power loss
NASA Technical Reports Server (NTRS)
Anderson, N. E.; Loewenthal, S. H.
1980-01-01
The results of an analysis of the effects of spur gear size, pitch, width, and ratio on total mesh power loss for a wide range of speeds, torques, and oil viscosities are presented. The analysis uses simple algebraic expressions to determine gear sliding, rolling, and windage losses and also incorporates an approximate ball bearing power loss expression. The analysis shows good agreement with published data. Large diameter and fine pitched gears had higher peak efficiencies but low part load efficiency. Gear efficiencies were generally greater than 98 percent except at very low torque levels. Tare (no-load) losses are generally a significant percentage of the full load loss except at low speeds.
Effect of geometry and operating conditions on spur gear system power loss
NASA Technical Reports Server (NTRS)
Anderson, N. E.; Loewenthal, S. H.
1980-01-01
The results of an analysis of the effects of spur gear size, pitch, width and ratio on total mesh power loss for a wide range of speeds, torques and oil viscosities are presented. The analysis uses simple algebraic expressions to determine gear sliding, rolling and windage losses and also incorporates an approximate ball bearing power loss expression. The analysis shows good agreement with published data. Large diameter and fine-pitched gears had higher peak efficiencies but lower part-load efficiency. Gear efficiencies were generally greater than 98 percent except at very low torque levels. Tare (no-load) losses are generally a significant percentage of the full-load loss except at low speeds.
NASA Astrophysics Data System (ADS)
Tsunegi, Sumito; Taniguchi, Tomohiro; Yakushiji, Kay; Fukushima, Akio; Yuasa, Shinji; Kubota, Hitoshi
2018-05-01
We investigated the spin-torque diode effect in a magnetic tunnel junction with FeB free layer. Vortex-core expulsion was observed near the boundary between vortex and uniform states. A high diode voltage of 24 mV was obtained with alternative input power of 0.3 µW, corresponding to huge diode sensitivity of 80,000 mV/mW. In the expulsion region, a broad peak in the high frequency region was observed, which is attributed to the weak excitation of uniform magnetization by thermal noise. The high diode sensitivity is of great importance for device applications such as telecommunications, radar detectors, and high-speed magnetic-field sensors.
Lack of Hypertonia in Thumb Muscles After Stroke
Kamper, Derek G.; Rymer, William Z.
2010-01-01
Despite the importance of the thumb to hand function, little is known about the origins of thumb impairment poststroke. Accordingly, the primary purpose of this study was to assess whether thumb flexors have heightened stretch reflexes (SRs) following stroke-induced hand impairment. The secondary purpose was to compare SR characteristics of thumb flexors in relation to those of finger flexors since it is unclear whether SR properties of both muscle groups are similarly affected poststroke. Stretch reflexes in thumb and finger flexors were assessed at rest on the paretic side in each of 12 individuals with chronic, severe, stroke-induced hand impairment and in the dominant thumb in each of eight control subjects also at rest. Muscle activity and passive joint flexion torques were measured during imposed slow (SS) and fast stretches (FS) of the flexors that span the metacarpophalangeal joints. Putative spasticity was then quantified in terms of the peak difference between FS and SS joint torques and electromyographic changes. For both the hemiparetic and control groups, the mean normalized peak torque differences (PTDs) measured in thumb flexors were statistically indistinguishable (P = 0.57). In both groups, flexor muscles were primarily unresponsive to rapid stretching. For 10 of 12 hemiparetic subjects, PTDs in thumb flexors were less than those in finger flexors (P = 0.03). Paretic finger flexor muscle reflex activity was consistently elicited during rapid stretching. These results may reflect an important difference between thumb and finger flexors relating to properties of the involved muscle afferents and spinal motoneurons. PMID:20668270
Efficacy of Sealing Agents on Preload Maintenance of Screw-Retained Implant-Supported Prostheses.
Seloto, Camila Berbel; Strazzi Sahyon, Henrico Badaoui; Dos Santos, Paulo Henrique; Delben, Juliana Aparecida; Assunção, Wirley Gonçalves
The aim of this study was to evaluate the effect of sealing agents on preload maintenance of screw joints. A total of four groups (n = 10 in each group) of abutment/implant systems, including external hexagon implants and antirotational UCLA abutments with a metallic collar in cobalt-chromium alloy, were assessed. In the control group (CG), no sealing agent was used at the abutment screw/implant interface. In the other groups, three different sealing agents were used at the abutment screw/implant interface: anaerobic sealing agent for medium torque (ASMT), anaerobic sealing agent for high torque (ASHT), and cyanoacrylate-based bonding agent (CYAB). All abutments were attached to the implants at 32 ± 1 N.cm. After 48 ± 2 hours of initial tightening, loosing torque (detorque) was measured using a digital torque wrench. Data were analyzed using Shapiro-Wilk, Wilcoxon, and Kruskal-Wallis tests, at 5% level of significance. In the CG and ASMT groups, detorque was lower than the insertion torque (24.6 ± 1.5 N.cm and 24.3 ± 1.1 N.cm, respectively). In the ASHT and CYAB groups, mean detorque increased in comparison to the insertion torque (51.0 ± 7.4 N.cm and 47.7 ± 15.1 N.cm, respectively). The ASHT was more efficient than the other sealing agents, increasing the remaining preload (detorque value) 58.88%. Although the cyanoacrylate-based bonding agent also generated high detorque values, the high standard deviation suggested its lower reliability.
Sensorless Sinusoidal Drives for Fan and Pump Motors by V/f Control
NASA Astrophysics Data System (ADS)
Kiuchi, Mitsuyuki; Ohnishi, Tokuo
This paper proposes sensorless sinusoidal driving methods of permanent magnet synchronous motors for fans and pumps by V/f control. The proposed methods are simple methods that control the motor peak current constant by voltage or frequency control, and are characterized by DC link current detection using a single shunt resistor at carrier wave signal bottom timing. As a result of the dumping factor from square torque load characteristics of fan and pump motors, it is possible to control stable starting and stable steady state by V/f control. In general, pressure losses as a result of the fluid pass of fan and pump systems are nearly constant; therefore, the flow rate and motor torque are determined by revolutions. Accordingly, high efficiency driving is possible by setting corresponding currents to q-axis currents (torque currents) at target revolutions. Because of the simple current detection and motor control methods, the proposed methods are optimum for fan and pump motor driving systems of home appliances.
The Zig-zag Instability of Streamlined Bodies
NASA Astrophysics Data System (ADS)
Guillet, Thibault; Coux, Martin; Quere, David; Clanet, Christophe
2017-11-01
When a floating bluff body, like a sphere, impacts water with a vertical velocity, its trajectory is straight and the depth of its dive increases with its initial velocity. Even though we observe the same phenomenon at low impact speed for axisymmetric streamlined bodies, the trajectory is found to deviate from the vertical when the velocity overcomes a critical value. This instability results from a competition between the destabilizing torque of the lift and the stabilizing torque of the Archimede's force. Balancing these torques yields a prediction on the critical velocity above which the instability appears. This theoretical value is found to depend on the position of the gravity center of the projectile and predicts with a full agreement the behaviour observed in our different experiments. Project funded by DGA.
The Simulation Study of Horizontal Axis Water Turbine Using Flow Simulation Solidworks Application
NASA Astrophysics Data System (ADS)
Prasetyo, H.; Budiana, EP; Tjahjana, DDDP; Hadi, S.
2018-02-01
The design of Horizontal Axis Water Turbine in pico hydro power plants involves many parameters. To simplify that, usually using computer simulation is applied. This research performs simulation process variation on turbine blade number, turbine blade curvature angle, turbine bucket angle and blocking system tilt angle. Those four variations were combined in order to obtain the best design of turbine. The study used Flow Simulation Solidworks application, and obtain data on turbine speed, pressure, force, and torque. However, this research focused on turbine torque value. The best design of turbine was obtained in the turbine with 6 blades, blade curvature angle of 65° and bucket angle of 10°, and blocking system tilt angle of 40°. In the best turbine, the produced torque value was 8.464 Nm.
Knee and ankle strength and lower extremity power in adolescent female ballet dancers.
Kenne, Ellinor; Unnithan, Viswanath B
2008-01-01
The aims of this study were twofold: (1) to compare the strength of four muscle groups of the lower limb (quadriceps [Q], hamstrings [H], plantar flexors [PF], and dorsiflexors [DF]) between female adolescent ballet dancers (BALs) and basketball players (BBs) over three angular velocities (30 degrees, 60 degrees and 90 degrees/sec) and two types of contraction (eccentric and concentric); and (2) to compare peak and mean power between the BALs and BBs. Eleven BALs (age: 15.8 +/- 1.2 years; stature: 163.9 +/- 6.2 cm; body mass: 56.3 +/- 5.7 kg; Tanner stage 4: N=10, stage 5: N=1) and ten BBs (age: 15.8 +/- 1.0 years; stature: 172.5 +/- 5.8 cm; body mass: 63.2 +/- 10.0 kg; Tanner stage 4: N=7, stage 5: N=3) volunteered to participate. Each participant performed one habituation session and one testing session on a Biodex isokinetic dynamometer to determine peak torque. Three angular velocities (30 degrees, 60 degrees and 90 degrees/sec) were used for each muscle group. To determine absolute and relative peak and mean power, participants performed a 30 second anaerobic Wingate test on a cycle ergometer. There were no significant differences in peak torque for Q, H, PF, and DF between the groups. Basketball players produced greater absolute peak power [569.7 +/- 82.2 vs. 454.6 +/- 79.3 W (p < .05)], relative peak power [9.1 +/- 1.3 vs. 8.1 +/- 1.0 W/kg body mass (p < .05)], absolute mean power [428.4 +/- 53.9 vs. 333.7 +/- 68.2 W (p < .05)] and relative mean power [6.83 +/- 0.7 vs. 5.9 +/- 0.7 W/kg (p < .05)] than BALs. Ballet dancers and BBs had similar isokinetically measured lower extremity muscular strength, but BALs generated lower levels of peak power and mean power compared to BBs.
Dailey, Bruno; Jordan, Laurence; Blind, Olivier; Tavernier, Bruno
2009-01-01
The passive fit of a superstructure on implant abutments is essential to success. One source of error when using a tapered cone-screw internal connection may be the difference between the tightening torque level applied to the abutments by the laboratory technician compared to that applied by the treating clinician. The purpose of this study was to measure the axial displacement of tapered cone-screw abutments into implants and their replicas as a function of the tightening torque level. Twenty tapered cone-screw abutments were selected. Two groups were created: 10 abutments were secured into 10 implants, and 10 abutments were secured into 10 corresponding implant replicas. Each abutment was tightened in increasing increments of 5 Ncm, from 0 Ncm to 45 Ncm, with a torque controller. The length of each sample was measured repeatedly with an Electronic Digital Micrometer. The mean axial displacement for the implant group and the replica group was calculated. The data were analyzed by the Mann-Whitney and Spearman tests. For both groups, there was always an axial displacement of the abutment upon each incremental application of torque. The mean axial displacement values varied between 7 and 12 microm for the implant group and between 6 and 21 microm for the replica group at each 5-Ncm increment. From 0 to 45 Ncm, the total mean axial displacement values were 89 microm for the implant group and 122 microm for the replica group. There was a continuous axial displacement of the abutments into implants and implant replicas when the applied torque was raised from 0 to 45 Ncm. Torque applied above the level recommended by the manufacturer increased the difference in displacement between the two groups.
2011-01-01
Background Several regression models have been proposed for estimation of isometric joint torque using surface electromyography (SEMG) signals. Common issues related to torque estimation models are degradation of model accuracy with passage of time, electrode displacement, and alteration of limb posture. This work compares the performance of the most commonly used regression models under these circumstances, in order to assist researchers with identifying the most appropriate model for a specific biomedical application. Methods Eleven healthy volunteers participated in this study. A custom-built rig, equipped with a torque sensor, was used to measure isometric torque as each volunteer flexed and extended his wrist. SEMG signals from eight forearm muscles, in addition to wrist joint torque data were gathered during the experiment. Additional data were gathered one hour and twenty-four hours following the completion of the first data gathering session, for the purpose of evaluating the effects of passage of time and electrode displacement on accuracy of models. Acquired SEMG signals were filtered, rectified, normalized and then fed to models for training. Results It was shown that mean adjusted coefficient of determination (Ra2) values decrease between 20%-35% for different models after one hour while altering arm posture decreased mean Ra2 values between 64% to 74% for different models. Conclusions Model estimation accuracy drops significantly with passage of time, electrode displacement, and alteration of limb posture. Therefore model retraining is crucial for preserving estimation accuracy. Data resampling can significantly reduce model training time without losing estimation accuracy. Among the models compared, ordinary least squares linear regression model (OLS) was shown to have high isometric torque estimation accuracy combined with very short training times. PMID:21943179
Wereszczynski, Jeff; Andricioaei, Ioan
2006-10-31
A precise understanding of the flexibility of double stranded nucleic acids and the nature of their deformed conformations induced by external forces is important for a wide range of biological processes including transcriptional regulation, supercoil and catenane removal, and site-specific recombination. We present, at atomic resolution, a simulation of the dynamics involved in the transitions from B-DNA and A-RNA to Pauling (P) forms and to denatured states driven by application of external torque and tension. We then calculate the free energy profile along a B- to P-transition coordinate and from it, compute a reversible pathway, i.e., an isotherm of tension and torque pairs required to maintain P-DNA in equilibrium. The reversible isotherm maps correctly onto a phase diagram derived from single molecule experiments, and yields values of elongation, twist, and twist-stretch coupling in agreement with measured values. We also show that configurational entropy compensates significantly for the large electrostatic energy increase due to closer-packed P backbones. A similar set of simulations applied to RNA are used to predict a novel structure, P-RNA, with its associated free energy, equilibrium tension, torque and structural parameters, and to assign the location, on the phase-diagram, of a putative force-torque-dependent RNA "triple point."
Electromagnetic processes during phase commutation in field regulated reluctance machine
NASA Astrophysics Data System (ADS)
Shishkov, A. N.; Sychev, D. A.; Zemlyansky, A. A.; Krupnova, M. N.; Funk, T. A.; Ishmet'eva, V. D.
2018-03-01
The processes of currents switching in stator windings have been explained by the existence of the electromagnetic torque ripples in the electric drive with the field-regulated reluctance machine. The maximum value of ripples in the open loop control system for the six-phase machine can reach 20 percent from the developed electromagnetic torque. This method allows one to make calculation of ripple spike towards average torque developed by the electromotor for the different number of phases. Application of a trapezoidal form of current at six phases became the solution. In case of a less number of phases than six, a ripple spike considerably increases, which is inadmissible. On the other hand, increasing the number of phases tends to the increase of the semiconductor inverter external dimensions based on the inconspicuous decreasing of a ripple spike. The creation and usage of high-speed control loops of current (HCLC) have been recommended for a reduction of the electromagnetic torque’s ripple level, as well as the appliance of positive current feedback in switching phase currents. This decision allowed one to receive a mean value of the torque more than 10%, compared to system without change, to reduce greatly ripple spike of the electromagnetic torque. The possibility of the electric drive effective operation with FRRM in emergency operation has been shown.
Major, Thomas W; Carey, Jason P; Nobes, David S; Heo, Giseon; Major, Paul W
2011-01-01
Axial rotation of orthodontic wire produces buccal or lingual root movement and is often referred to as third-order movement or "torque expression." The objective of this study was to quantify torque expression in 3 self-ligation bracket systems (Damon Q, Ormco, Orange, Calif; In-Ovation R, GAC, Bohemia, NY; and Speed, Strite Industries, Cambridge, Ontario, Canada) during loading and unloading. A stepper motor was used to rotate a wire in a fixed bracket slot from -15° to 63° in 3° increments, and then back to -15°. The bracket was mounted on top of a load cell that measured forces and moments in all directions. Damon's and In-Ovation's maximum average torque values at 63° were 105 and 113 Nmm, respectively. Many Speed brackets experienced premature loss of torque between 48° and 63°, and the average maximum was 82 Nmm at 54°. The torque plays for Damon, In-Ovation, and Speed were 11.3°, 11.9°, and 10.8°, respectively. Generally, In-Ovation expressed the most torque at a given angle of twist, followed by Damon and then Speed. However, there was no significant difference between brackets below 34 Nmm of torque. From a clinical perspective, the torque plays between brackets were virtually indistinguishable. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Wollner, Bertram C
1948-01-01
Contains charts for use in determining preliminary values of the spanwise-load, shear, bending-moment, and accumulated-torque distributions of swept wings. The charts are based on strip theory and include four aerodynamic-load distributions, two section-moment distributions, and two inertia-load distributions. The taper ratios considered cover the range from 1.0 to 0 and the results are applicable to any angle of sweep.
Inoue, Gen; Ueno, Masaki; Nakazawa, Toshiyuki; Imura, Takayuki; Saito, Wataru; Uchida, Kentaro; Ohtori, Seiji; Toyone, Tomoaki; Takahira, Naonobu; Takaso, Masashi
2014-09-01
The object of this study was to examine the efficacy of preoperative teriparatide treatment for increasing the insertional torque of pedicle screws during fusion surgery in postmenopausal women with osteoporosis. Fusion surgery for the thoracic and/or lumbar spine was performed in 29 postmenopausal women with osteoporosis aged 65-82 years (mean 72.2 years). The patients were divided into 2 groups based on whether they were treated with teriparatide (n = 13) or not (n = 16) before the surgery. In the teriparatide-treated group, patients received preoperative teriparatide therapy as either a daily (20 μg/day, n = 7) or a weekly (56.5 μg/week, n = 6) injection for a mean of 61.4 days and a minimum of 31 days. During surgery, the insertional torque was measured in 212 screws inserted from T-7 to L-5 and compared between the 2 groups. The correlation between the insertional torque and the duration of preoperative teriparatide treatment was also investigated. The mean insertional torque value in the teriparatide group was 1.28 ± 0.42 Nm, which was significantly higher than in the control group (1.08 ± 0.52 Nm, p < 0.01). There was no significant difference between the daily and the weekly teriparatide groups with respect to mean insertional torque value (1.34 ± 0.50 Nm and 1.18 ± 0.43 Nm, respectively, p = 0.07). There was negligible correlation between insertional torque and duration of preoperative teriparatide treatment (r(2) = 0.05, p < 0.01). Teriparatide injections beginning at least 1 month prior to surgery were effective in increasing the insertional torque of pedicle screws during surgery in patients with postmenopausal osteoporosis. Preoperative teriparatide treatment might be an option for maximizing the purchase of the pedicle screws to the bone at the time of fusion surgery.
Friction measurement in a hip wear simulator.
Saikko, Vesa
2016-05-01
A torque measurement system was added to a widely used hip wear simulator, the biaxial rocking motion device. With the rotary transducer, the frictional torque about the drive axis of the biaxial rocking motion mechanism was measured. The principle of measuring the torque about the vertical axis above the prosthetic joint, used earlier in commercial biaxial rocking motion simulators, was shown to sense only a minor part of the total frictional torque. With the present method, the total frictional torque of the prosthetic hip was measured. This was shown to consist of the torques about the vertical axis above the joint and about the leaning axis. Femoral heads made from different materials were run against conventional and crosslinked polyethylene acetabular cups in serum lubrication. Regarding the femoral head material and the type of polyethylene, there were no categorical differences in frictional torque with the exception of zirconia heads, with which the lowest values were obtained. Diamond-like carbon coating of the CoCr femoral head did not reduce friction. The friction factor was found to always decrease with increasing load. High wear could increase the frictional torque by 75%. With the present system, friction can be continuously recorded during long wear tests, so the effect of wear on friction with different prosthetic hips can be evaluated. © IMechE 2016.
Placzek, R; Deuretzbacher, G; Meiss, A L
2002-12-01
It is claimed in the literature that hydroxyapatite(HA)-coated screws of external fixators have superior fixation strength in bone, which is postulated to lead to a substantial decrease in loosening and infection rates. We report on a study of the maximum torque values developed while inserting and removing 30 HA-coated Schanz screws of 8 Heidelberg external fixation systems applied to the tibia to correct leg length differences and axial deformities. The infection rate was determined in accordance with defined criteria, and was found to be about 20% for the HA-coated screws. Screws without infection showed an extraction torque above insertion torque, screws with infection an extraction torque below. A significant correlation (p = 0.05) was seen between infection and decrease in fixation strength (quotient: loosening torque/tightening torque). To exclude the impact of such biological processes as osteointegration and bone remodelling, the clinical results were compared with the torques measured for coated and uncoated Schanz screws in a human cadaveric tibia. A significantly higher fixation strength in bone was found for HA-coated screws in comparison with uncoated screws (p = 0.002). These data warrant a clinical study directly comparing HA-coated and uncoated Schanz screws.
The Relationships Among Isokinetic Endurance, Initial Strength Level, and Fiber Type.
ERIC Educational Resources Information Center
Clarkson, Priscilla M.; And Others
1982-01-01
Knee extension isokinetic peak torque was assessed at four angular velocities, and isokinetic endurance was assessed in eight college age men. Muscle fiber type was determined and related to isokinetic strength and fatigability. Results indicate that factors other than fiber type and initial strength level must influence the rate of isokinetic…
Buford, Thomas W; Rossi, Stephen J; Smith, Douglas B; O'Brien, Matthew S; Pickering, Chris
2006-08-01
The purpose of the present investigation was to examine the effects of a collegiate wrestling season on body weight, hydration, and muscular performance. Twelve Division I collegiate wrestlers (mean +/- SE; 20.75 +/- 0.41 year) volunteered to participate in testing sessions during midseason and 3 weeks following the season. Testing consisted of weigh-in, providing a urine sample for hydration analysis, and a measure of isometric leg extension peak torque. Weight significantly increased (p < 0.05) following the completion of the competitive season. No significant change in urine specific gravity (p > 0.05) was observed. Muscular performance was affected by the season as peak torque (PT) and PT-to-body weight ratio increased significantly (p < 0.05). Following the collegiate wrestling season, augmentation in body weight and muscular performance of the wrestlers occurs without alterations in hydration status. Further research is warranted on what type of strength training program would most effectively reduce the decrements in strength associated with weight loss and the strain of a competitive season.
Isokinetic Hamstrings:Quadriceps Ratios in Intercollegiate Athletes
Fogarty, Tracey D.; Mahaffey, Brian L.
2001-01-01
Objective: To compare the differences in the concentric hamstrings:quadriceps (H:Q) ratio among athletes in different sports at 3 velocities. Design and Setting: We measured the H:Q ratio of both knees using the Biodex Pro Isokinetic Device. Subjects: Eighty-one male and female collegiate athletes. Measurements: We performed analyses for sport, velocity, and side of body for each sex. To compare the means of the concentric H:Q ratios for mean peak torque and mean total work, a 2 × 3 × 4 mixed-factorial analysis of variance was computed for women and a 2 × 2 × 3 mixed-factorial analysis of variance was computed for men. Results: We observed no significant interactions for men and women for the concentric H:Q ratio for mean peak torque. There was a significant mean difference among velocity conditions and a significant difference for men with respect to velocity. No significant differences were found for side of body or sport. Conclusions: The H:Q ratio increased as velocity increased. No differences existed for the H:Q ratio for sport or side of body. PMID:12937479
Oscillation characteristics of zero-field spin transfer oscillators with field-like torque
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guo, Yuan-Yuan; Xue, Hai-Bin, E-mail: xuehaibin@tyut.edu.cn; Department of Physics and Optoelectronics, Taiyuan University of Technology, Taiyuan 030024
2015-05-15
We theoretically investigate the influence of the field-like spin torque term on the oscillation characteristics of spin transfer oscillators, which are based on MgO magnetic tunnel junctions (MTJs) consisting of a perpendicular magnetized free layer and an in-plane magnetized pinned layer. It is demonstrated that the field-like torque has a strong impact on the steady-state precession current region and the oscillation frequency. In particular, the steady-state precession can occur at zero applied magnetic field when the ratio between the field-like torque and the spin transfer torque takes up a negative value. In addition, the dependence of the oscillation properties onmore » the junction sizes has also been analyzed. The results indicate that this compact structure of spin transfer oscillator without the applied magnetic field is practicable under certain conditions, and it may be a promising configuration for the new generation of on-chip oscillators.« less
Schwiesau, Jens; Schilling, Carolin; Kaddick, Christian; Utzschneider, Sandra; Jansson, Volkmar; Fritz, Bernhard; Blömer, Wilhelm; Grupp, Thomas M
2013-05-01
The objective of our study was the definition of testing scenarios for knee wear simulation under various highly demanding daily activities of patients after total knee arthroplasty. This was mainly based on a review of published data on knee kinematics and kinetics followed by the evaluation of the accuracy and precision of a new experimental setup. We combined tibio-femoral load and kinematic data reported in the literature to develop deep squatting loading profiles for simulator input. A servo-hydraulic knee wear simulator was customised with a capability of a maximum flexion of 120°, a tibio-femoral load of 5000N, an anterior-posterior (AP) shear force of ±1000N and an internal-external (IE) rotational torque of ±50Nm to simulate highly demanding patient activities. During the evaluation of the newly configurated simulator the ability of the test machine to apply the required load and torque profiles and the flexion kinematics in a precise manner was examined by nominal-actual profile comparisons monitored periodically during subsequent knee wear simulation. For the flexion kinematics under displacement control a delayed actuator response of approximately 0.05s was inevitable due to the inertia of masses in movement of the coupled knee wear stations 1-3 during all applied activities. The axial load and IE torque is applied in an effective manner without substantial deviations between nominal and actual load and torque profiles. During the first third of the motion cycle a marked deviation between nominal and actual AP shear load profiles has to be noticed but without any expected measurable effect on the latter wear simulation due to the fact that the load values are well within the peak magnitude of the nominal load amplitude. In conclusion the described testing method will be an important tool to have more realistic knee wear simulations based on load conditions of the knee joint during activities of daily living. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.
Marković, Aleksa; Mišić, Tijana; Miličić, Biljana; Calvo-Guirado, Jose Luis; Aleksić, Zoran; Ðinić, Ana
2013-07-01
The study aimed to investigate the effect of surgical technique, implant macrodesign and insertion torque on bone temperature changes during implant placement. In the in vitro study, 144 self-tapping (blueSKY(®) 4 × 10 mm; Bredent) and 144 non-self-tapping (Standard implant(®) 4.1 × 10 mm; Straumann) were placed in osteotomies prepared in pig ribs by lateral bone condensing or bone drilling techniques. The maximum insertion torque values of 30, 35 and 40 Ncm were used. Real-time bone temperature measurement during implant placement was performed by three thermocouples positioned vertically, in tripod configuration around every osteotomy, at a distance of 5 mm from it and at depths of 1, 5 and 10 mm. Data were analysed using Kruskal-Wallis, Mann-Whitney U-tests and Regression analysis. Significant predictor of bone temperature at the osteotomy depth of 1 mm was insertion torque (P = 0.003) and at the depth of 10-mm implant macrodesign (P = 0.029), while no significant predictor at depth of 5 mm was identified (P > 0.05). Higher insertion torque values as well as non-self-tapping implant macrodesign were related to higher temperatures. Implant placement in sites prepared by bone drilling induced significantly higher temperature increase (P = 0.021) compared with bone condensing sites at the depth of 5 mm, while no significant difference was recorded at other depths. Compared with 30 Ncm, insertion torque values of 35 and 40 Ncm produced significantly higher temperature increase (P = 0.005; P = 0.003, respectively) at the depth of 1 mm. There was no significant difference in temperature change induced by 35 and 40 Ncm, neither by implant macrodesign at all investigated depths (P > 0.05). Placement of self-tapping implants with low insertion torque into sites prepared by lateral bone condensing technique might be advantageous in terms of thermal effect on bone. © 2012 John Wiley & Sons A/S.
Condition Based vs. Time Based Maintenance: Case Study on Hypergolic Pumps
NASA Technical Reports Server (NTRS)
Gibson, Lewis J.
2007-01-01
Two Pad 39B Ox pumps were monitored with the Baker Instruments Explorer Motor tester. Using the torque spectrum it was determined that Ox pump #2 had a significant peak at a frequency, which indicated lubricant fluid whirl. Similar testing on Ox pump #1 didn't indicate this peak, an indication that this pump was in good mechanical condition. Subsequent disassembly of both motors validated these findings. Ox pump #2 rear bearing showed significant wear, the front bearing showed little wear. Ox pump #1 was still within manufacturers tolerances.
Epprecht, Alyssa; Zeltner, Marco; Benic, Goran
2018-01-01
Abstract This study quantified the strain development after inserting implant‐borne fixed dental prosthesis (FDP) to various implant–abutment joints. Two bone‐level implants (∅ = 4.1 mm, RC, SLA 10 mm, Ti, Straumann) were inserted in polyurethane models (N = 3) in the area of tooth nos 44 and 47. Four‐unit veneered zirconium dioxide FDPs (n = 2) were fabricated, one of which was fixed on engaging (E; RC Variobase, ∅ = 4.5 mm, H = 3.5 mm) and the other on non‐engaging (NE) abutments (RC Variobase, ∅ = 4.5 mm, H = 5.5 mm). One strain gauge was bonded to the occlusal surface of pontic no. 46 on the FDP and the other two on the polyurethane model. Before (baseline) and after torque (35 Ncm), strain values were recorded three times. Data were analyzed using Kruskal–Wallis and Mann–Whitney U tests (α = 0.05). Mean strain values presented significant increase after torque for both E and NE implant–abutment connection type (baseline: E = 4.33 ± 4.38; NE = 4.85 ± 4.85; torque: E = 196.56 ± 188.02; NE = 275.63 ± 407.7; p < .05). Mean strain values based on implant level presented significant increase after torque for both E and NE implant–abutment connection (baseline: E = 4.94 ± 5.29; NE = 5.78 ± 5.69; torque: E = 253.78 ± 178.14; NE = 347.72 ± 493.06; p < .05). The position of the strain gauge on implants (p = .895), FDP (p = .275), and abutment connection type (p = .873) did not significantly affect the strain values. Strain levels for zirconium dioxide implant‐borne FDPs were not affected by the implant–abutment connection type. PMID:29744210
Unusual negative permeability of single magnetic nanowire excited by the spin transfer torque effect
NASA Astrophysics Data System (ADS)
Han, Mangui; Zhou, Wu
2018-07-01
Due to the effect of spin transfer torque, negative imaginary parts of permeability (μ″ < 0) are reported in a ferromagnetic nanowire. It is found that negative μ″ values are resulted from the interaction of spin polarized conduction electrons with the spatially non-uniform distributed magnetic moments at both ends of nanowires. The results are well explained from the effect of spin transfer torque on the precession of magnetization under the excitation of both the pulsed magnetic field and static electric field.
Torque scaling in small-gap Taylor-Couette flow with smooth or grooved wall
NASA Astrophysics Data System (ADS)
Zhu, Bihai; Ji, Zengqi; Lou, Zhengkun; Qian, Pengcheng
2018-03-01
The torque in the Taylor-Couette flow for radius ratios η ≥0.97 , with smooth or grooved wall static outer cylinders, is studied experimentally, with the Reynolds number of the inner cylinder reaching up to Rei=2 ×105 , corresponding to the Taylor number up to Ta =5 ×1010 . The grooves are perpendicular to the mean flow, and similar to the structure of a submersible motor stator. It is found that the dimensionless torque G , at a given Rei and η , is significantly greater for grooved cases than smooth cases. We compare our experimental torques for the smooth cases to the fit proposed by Wendt [F. Wendt, Ing.-Arch. 4, 577 (1993), 10.1007/BF02084936] and the fit proposed by Bilgen and Boulos [E. Bilgen and R. Boulos, J Fluids Eng. 95, 122 (1973), 10.1115/1.3446944], which shows both fits are outside their range for small gaps. Furthermore, an additional dimensionless torque (angular velocity flux) N uω in the smooth cases exhibits an effective scaling of N uω˜T a0.39 in the ultimate regime, which occurs at a lower Taylor number, Ta ≈3.5 ×107 , than the well-explored η =0.714 case (at Ta ≈3 ×108 ). The same effective scaling exponent, 0.39, is also evident in the grooved cases, but for η =0.97 and 0.985, there is a peak before this exponent appears.
Abdel-aziem, Amr Almaz; Mohammad, Walaa Sayed
2012-01-01
The aim of this study was to examine the long-term effects of static stretching of the plantar-flexor muscles on eccentric and concentric torque and ankle dorsiflexion range of motion in healthy subjects. Seventy five healthy male volunteers, with no previous history of trauma to the calf that required surgery, absence of knee flexion contracture and no history of neurologic dysfunction or disease, systemic disease affecting the lower extremities were selected for this study. The participants were divided into three equal groups. The control group did not stretch the plantar-flexor muscles. Two Experimental groups (trained and untrained) were instructed to perform static stretching exercise of 30 second duration and 5 repetitions twice daily. The stretching sessions were carried out 5 days a week for 6 weeks. The dorsiflexion range of motion was measured in all subjects. Also measured was the eccentric and concentric torque of plantar-flexors at angular velocities of 30 and 120°/s pre and post stretching. Analysis of variance showed a significant increase in plantar-flexor eccentric and concentric torque (p < 0.05) of trained and untrained groups, and an increase in dorsiflexion range of motion (p < 0.05) at both angular velocities for the untrained group only. The static stretching program of plantar-flexors was effective in increasing the concentric and eccentric plantarflexion torque at angular velocities of 30 and 120°/s. Increases in plantar-flexors flexibility were observed in untrained subjects. PMID:23486840
Zhang, Juanjuan; Collins, Steven H.
2017-01-01
This study uses theory and experiments to investigate the relationship between the passive stiffness of series elastic actuators and torque tracking performance in lower-limb exoskeletons during human walking. Through theoretical analysis with our simplified system model, we found that the optimal passive stiffness matches the slope of the desired torque-angle relationship. We also conjectured that a bandwidth limit resulted in a maximum rate of change in torque error that can be commanded through control input, which is fixed across desired and passive stiffness conditions. This led to hypotheses about the interactions among optimal control gains, passive stiffness and desired quasi-stiffness. Walking experiments were conducted with multiple angle-based desired torque curves. The observed lowest torque tracking errors identified for each combination of desired and passive stiffnesses were shown to be linearly proportional to the magnitude of the difference between the two stiffnesses. The proportional gains corresponding to the lowest observed errors were seen inversely proportional to passive stiffness values and to desired stiffness. These findings supported our hypotheses, and provide guidance to application-specific hardware customization as well as controller design for torque-controlled robotic legged locomotion. PMID:29326580
NASA Astrophysics Data System (ADS)
Mohan, N. S.; Kulkarni, S. M.
2018-01-01
Polymer based composites have marked their valuable presence in the area of aerospace, defense and automotive industry. Components made of composite, are assembled to main structure by fastener, which require accurate, precise high quality holes to be drilled. Drilling the hole in composite with accuracy require control over various processes parameters viz., speed, feed, drill bit size and thickens of specimen. TRIAC VMC machining center is used to drill the hole and to relate the cutting and machining parameters on the torque. MINITAB 14 software is used to analyze the collected data. As a function of cutting and specimen parameters this method could be useful for predicting torque parameters. The purpose of this work is to investigate the effect of drilling parameters to get low torque value. Results show that thickness of specimen and drill bit size are significant parameters influencing the torque and spindle speed and feed rate have least influence and overlaid plot indicates a feasible and low region of torque is observed for medium to large sized drill bits for the range of spindle speed selected. Response surface contour plots indicate the sensitivity of the drill size and specimen thickness to the torque.
A universal ankle-foot prosthesis emulator for human locomotion experiments.
Caputo, Joshua M; Collins, Steven H
2014-03-01
Robotic prostheses have the potential to significantly improve mobility for people with lower-limb amputation. Humans exhibit complex responses to mechanical interactions with these devices, however, and computational models are not yet able to predict such responses meaningfully. Experiments therefore play a critical role in development, but have been limited by the use of product-like prototypes, each requiring years of development and specialized for a narrow range of functions. Here we describe a robotic ankle-foot prosthesis system that enables rapid exploration of a wide range of dynamical behaviors in experiments with human subjects. This emulator comprises powerful off-board motor and control hardware, a flexible Bowden cable tether, and a lightweight instrumented prosthesis, resulting in a combination of low mass worn by the human (0.96 kg) and high mechatronic performance compared to prior platforms. Benchtop tests demonstrated closed-loop torque bandwidth of 17 Hz, peak torque of 175 Nm, and peak power of 1.0 kW. Tests with an anthropomorphic pendulum "leg" demonstrated low interference from the tether, less than 1 Nm about the hip. This combination of low worn mass, high bandwidth, high torque, and unrestricted movement makes the platform exceptionally versatile. To demonstrate suitability for human experiments, we performed preliminary tests in which a subject with unilateral transtibial amputation walked on a treadmill at 1.25 ms-1 while the prosthesis behaved in various ways. These tests revealed low torque tracking error (RMS error of 2.8 Nm) and the capacity to systematically vary work production or absorption across a broad range (from -5 to 21 J per step). These results support the use of robotic emulators during early stage assessment of proposed device functionalities and for scientific study of fundamental aspects of human-robot interaction. The design of simple, alternate end-effectors would enable studies at other joints or with additional degrees of freedom.
The effects of short-term exercise training on peak-torque are time- and fiber-type dependent.
Ureczky, Dóra; Vácz, Gabriella; Costa, Andreas; Kopper, Bence; Lacza, Zsombor; Hortobágyi, Tibor; Tihanyi, József
2014-08-01
We examined the susceptibility of fast and slow twitch muscle fibers in the quadriceps muscle to eccentric exercise-induced muscle damage. Nine healthy men (age: 22.5 ± 1.6 years) performed maximal eccentric quadriceps contractions at 120°·s-1 over a 120° of knee joint range of motion for 6 consecutive days. Biopsies were taken from the vastus lateralis muscle before repeated bouts of eccentric exercise on the third and seventh day. Immunohistochemical procedures were used to determine fiber composition and fibronectin activity. Creatine kinase (CK) and lactate dehydrogenase (LDH) were determined in serum. Average torque was calculated in each day for each subject. Relative to baseline, average torque decreased 37.4% till day 3 and increased 43.0% from the day 3 to day 6 (p < 0.001). Creatine kinase and LDH were 70.6 and 1.5 times higher on day 3 and 75.5 and 1.4 times higher on day 6. Fibronectin was found in fast fibers in subjects with high CK level on day 3 and 7 after exercise, but on day 7, fibronectin seemed in both slow and fast fibers except in muscles of 2 subjects with high fast fiber percentage. Peak torque and muscle fiber-type composition measured at baseline showed a strong positive association on day 3 (r = 0.76, p < 0.02) and strong negative association during recovery between day 3 and day 6 (r = -0.76, p < 0.02), and day 1 and day 6 (r = 0.84, p < 0.001). We conclude that the damage of fast fibers preceded the damage of slow fibers, and muscles with slow fiber dominance were more susceptible to repeated bouts of eccentric exercise than fast fiber dominance muscles. The data suggest that the responses to repeated bouts of eccentric exercise are fiber-type-dependent in the quadriceps muscle, which can be the basis for the design of individualized strength training protocols.
40 CFR Appendix A to Subpart D of... - Tables
Code of Federal Regulations, 2010 CFR
2010-07-01
...-test and post-test values) kPa Pv Saturation pressure at dew point temperature kPa Ra Relative humidity...) CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Emission Test Equipment... Percent torque related to maximum torque for the test mode % mass Pollutant mass flow g/h nd, i Engine...
40 CFR Appendix A to Subpart D of... - Tables
Code of Federal Regulations, 2011 CFR
2011-07-01
... post-test values) kPa Ra Relative humidity of the ambient air percent T Absolute temperature at air...) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Emission Test Equipment... torque related to maximum torque for the test mode percent mass Pollutant mass flow g/h nd, i Engine...
40 CFR Appendix A to Subpart D of... - Tables
Code of Federal Regulations, 2013 CFR
2013-07-01
... post-test values) kPa Ra Relative humidity of the ambient air percent T Absolute temperature at air...) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Emission Test Equipment... torque related to maximum torque for the test mode percent mass Pollutant mass flow g/h nd, i Engine...
40 CFR Appendix A to Subpart D of... - Tables
Code of Federal Regulations, 2010 CFR
2010-07-01
... post-test values) kPa Ra Relative humidity of the ambient air percent T Absolute temperature at air...) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Emission Test Equipment... torque related to maximum torque for the test mode percent mass Pollutant mass flow g/h nd, i Engine...
40 CFR Appendix A to Subpart D of... - Tables
Code of Federal Regulations, 2014 CFR
2014-07-01
...-test and post-test values) kPa Pv Saturation pressure at dew point temperature kPa Ra Relative humidity...) CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Emission Test Equipment... Percent torque related to maximum torque for the test mode % mass Pollutant mass flow g/h nd, i Engine...
40 CFR Appendix A to Subpart D of... - Tables
Code of Federal Regulations, 2011 CFR
2011-07-01
...-test and post-test values) kPa Pv Saturation pressure at dew point temperature kPa Ra Relative humidity...) CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Emission Test Equipment... Percent torque related to maximum torque for the test mode % mass Pollutant mass flow g/h nd, i Engine...
40 CFR Appendix A to Subpart D of... - Tables
Code of Federal Regulations, 2012 CFR
2012-07-01
...-test and post-test values) kPa Pv Saturation pressure at dew point temperature kPa Ra Relative humidity...) CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Emission Test Equipment... Percent torque related to maximum torque for the test mode % mass Pollutant mass flow g/h nd, i Engine...
40 CFR Appendix A to Subpart D of... - Tables
Code of Federal Regulations, 2012 CFR
2012-07-01
... post-test values) kPa Ra Relative humidity of the ambient air percent T Absolute temperature at air...) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Emission Test Equipment... torque related to maximum torque for the test mode percent mass Pollutant mass flow g/h nd, i Engine...
40 CFR Appendix A to Subpart D of... - Tables
Code of Federal Regulations, 2014 CFR
2014-07-01
... post-test values) kPa Ra Relative humidity of the ambient air percent T Absolute temperature at air...) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Emission Test Equipment... torque related to maximum torque for the test mode percent mass Pollutant mass flow g/h nd, i Engine...
40 CFR Appendix A to Subpart D of... - Tables
Code of Federal Regulations, 2013 CFR
2013-07-01
...-test and post-test values) kPa Pv Saturation pressure at dew point temperature kPa Ra Relative humidity...) CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Emission Test Equipment... Percent torque related to maximum torque for the test mode % mass Pollutant mass flow g/h nd, i Engine...
78 FR 56601 - Airworthiness Directives; Fokker Services B.V. Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-13
... torque values of nuts on circuit breakers, contactors, and terminal blocks of the EPC and battery relay... blocks of the EPC and battery relay panel, as applicable; and do all applicable adjustments of the torque... contacts and nuts on circuit breakers, contactors, and terminal blocks of the EPC and battery relay panel...
NASA Astrophysics Data System (ADS)
Bassan, M.; Cavalleri, A.; De Laurentis, M.; De Marchi, F.; De Rosa, R.; Di Fiore, L.; Dolesi, R.; Finetti, N.; Garufi, F.; Grado, A.; Hueller, M.; Marconi, L.; Milano, L.; Minenkov, Y.; Pucacco, G.; Stanga, R.; Vetrugno, D.; Visco, M.; Vitale, S.; Weber, W. J.
2018-01-01
In this paper we report on measurements on actuation crosstalk, relevant to the gravitational reference sensors for LISA Pathfinder and LISA. In these sensors, a Test Mass (TM) falls freely within a system of electrodes used for readout and control. These measurements were carried out on ground with a double torsion pendulum that allowed us to estimate both the torque injected into the sensor when a control force is applied and, conversely, the force leaking into the translational degree of freedom due to the applied torque.The values measured on our apparatus (the engineering model of the LISA Pathfinder sensor) agree to within 0.2% (over a maximum measured crosstalk of 1%) with predictions of a mathematical model when measuring force to torque crosstalk, while it is somewhat larger than expected (up to 3.5%) when measuring torque to force crosstalk. However, the values in the relevant range, i.e. when the TM is well centered ( ± 10 μm) in the sensor, remain smaller than 0.2%, satisfying the LISA Pathfinder requirements.
Ribeiro, Fernanda; Lépine, Pierre-Alexis; Garceau-Bolduc, Corine; Coats, Valérie; Allard, Étienne; Maltais, François; Saey, Didier
2015-01-01
Background The purpose of this study was to determine and compare the test-retest reliability of quadriceps isokinetic endurance testing at two knee angular velocities in patients with chronic obstructive pulmonary disease (COPD). Methods After one familiarization session, 14 patients with moderate to severe COPD (mean age 65±4 years; forced expiratory volume in 1 second (FEV1) 55%±18% predicted) performed two quadriceps isokinetic endurance tests on two separate occasions within a 5–7-day interval. Quadriceps isokinetic endurance tests consisted of 30 maximal knee extensions at angular velocities of 90° and 180° per second, performed in random order. Test-retest reliability was assessed for peak torque, muscle endurance, work slope, work fatigue index, and changes in FEV1 for dyspnea and leg fatigue from rest to the end of the test. The intraclass correlation coefficient, minimal detectable change, and limits of agreement were calculated. Results High test-retest reliability was identified for peak torque and muscle total work at both velocities. Work fatigue index was considered reliable at 90° per second but not at 180° per second. A lower reliability was identified for dyspnea and leg fatigue scores at both angular velocities. Conclusion Despite a limited sample size, our findings support the use of a 30-maximal repetition isokinetic muscle testing procedure at angular velocities of 90° and 180° per second in patients with moderate to severe COPD. Endurance measurement (total isokinetic work) at 90° per second was highly reliable, with a minimal detectable change at the 95% confidence level of 10%. Peak torque and fatigue index could also be assessed reliably at 90° per second. Evaluation of dyspnea and leg fatigue using the modified Borg scale of perceived exertion was poorly reliable and its clinical usefulness is questionable. These results should be useful in the design and interpretation of future interventions aimed at improving muscle endurance in COPD. PMID:26124656
Hastings, Mary K.; Mueller, Michael J.
2012-01-01
Background and Purpose The exercise guidelines for people with diabetes mellitus and peripheral neuropathy (DM+PN) have recently changed to allow moderate-intensity weight-bearing exercise, but there are few reports in the literature describing appropriate weight-bearing exercise for those with DM+PN. This case report describes a successful and safe progressive exercise program for an individual with DM+PN. Case Description The patient was a 76-year-old man with a 30-year history of DM+PN. He participated in a 12-week, moderate-intensity, progressive exercise program (heart rate approximately 75% of maximum heart rate; rate of perceived exertion=11–13; 3 times per week) involving walking on a treadmill, balance exercises, and strengthening exercises for the lower extremities using body weight resistance. Outcomes Measurements were taken before and after the 12 weeks of exercise. The patient's Six-Minute Walk Test distance increased from 1,200 to 1,470 ft. His Physical Performance Test score did not change. His Foot and Ankle Ability Measure questionnaire score improved from 89 to 98. Dorsiflexor and plantar-flexor peak torque increased (dorsiflexor peak torque: right side=4.5–4.6 N·m, left side=2.8–3.8 N·m; plantar-flexor peak torque: right side=44.7–62.4 N·m, left side=40.8–56.0 N·m), as did his average daily step count (6,176–8,273 steps/day). Close monitoring of the plantar surface of the feet indicated that the exercise program was well tolerated and there were no adverse events. Discussion and Conclusions This case report describes a moderate-intensity exercise program that was successful in increasing some measures of muscle strength, physical function, and activity without causing injury in an individual with DM+PN. PMID:21921252
Musculoskeletal profile of middle-aged Ving Tsun Chinese martial art practitioners
Fong, Shirley S.M.; Chan, Jessie S.M.; Bae, Young-Hyeon; Yam, Timothy T.T.; Chung, Louisa M.Y.; Ma, Ada W.W.; Kuisma, Raija
2017-01-01
Abstract This cross-sectional exploratory study aimed to quantify and compare the axial and appendicular bone mineral density (BMD), muscle mass, and muscle strength of middle-aged practitioners of Ving Tsun (VT; a hard-style Chinese martial art) with those of nonpractitioners. Eighteen VT practitioners (mean age ± standard deviation = 51.8 ± 17.7 years; 12 men and six women) and 36 active controls (mean age ± standard deviation = 58.7 ± 11.0 years; 18 men and 18 women) participated in the study. All participants underwent a 1-day battery of musculoskeletal examinations. The BMD of the total radius, total hip, femoral neck, and lumbar spine was measured using dual-energy X-ray absorptiometry, as was the lean mass of the arm, leg, and trunk. Muscle strength of the upper and lower limbs was assessed using a Jamar dynamometer and an isokinetic dynamometer at 60°/second, respectively. VT-trained participants had a 11.5% higher total radius BMD (P = 0.023), a 17.8% higher leg lean mass (P = 0.014), a 56.4% higher isokinetic body weight-adjusted peak torque of the knee extensors (P < 0.001), a 60.8% higher isokinetic body weight-adjusted peak torque of knee flexors (P < 0.001), and a 31.4% shorter time to reach peak torque in the knee flexors (P = 0.001) than the active controls. No significant differences were found in any of the other musculoskeletal outcomes between the 2 groups (P > 0.05). Middle-aged VT practitioners displayed a higher total radius BMD and leg lean mass and better knee extensor and flexor muscular performances than their healthy active counterparts. Healthcare professionals may consider using this alternative method of training to improve the musculoskeletal health of middle-aged adults. PMID:28121945
The effect of milk on recovery from repeat-sprint cycling in female team-sport athletes.
Rankin, Paula; Lawlor, Michael J; Hills, Frank A; Bell, Phillip G; Stevenson, Emma J; Cockburn, Emma
2018-02-01
The consumption of milk following eccentric exercise attenuates the effects of muscle damage in team-sport athletes. However, participation in team sport involves both concentric-eccentric loading and metabolic stress. Therefore, the aim of this study was to investigate the effects of postexercise milk consumption on recovery from a cycling protocol designed to simulate the metabolic demands of team sport. Ten female team-sport athletes participated in a randomised crossover investigation. Upon completion of the protocol participants consumed 500 mL of milk (MILK) or 500 mL of an energy-matched carbohydrate (CHO) drink. Muscle function (peak torque, rate of force development, countermovement jump, 20-m sprint), muscle soreness and tiredness, serum creatine kinase, high-sensitivity C-reactive protein, and measures of oxidative stress (protein carbonyls and reduced glutathione/oxidized glutathione (GSH/GSSG) ratio) were determined at pre-exercise and 24 h, 48 h, and 72 h postexercise. MILK had a possible beneficial effect in attenuating losses in peak torque (180°/s) from baseline to 24 h (3.2% ± 7.8% vs. -6.2% ± 7.5%, MILK vs. CHO) and a possible beneficial effect in minimising soreness (baseline-48 h; baseline-72 h) and tiredness (baseline-24 h; baseline-72 h). There was no change in oxidative stress following the exercise protocol, though a likely benefit of milk was observed for GSH/GSSG ratio at baseline-24 h (0.369 ×/÷ 1.89, 1.103 ×/÷ 3.96, MILK vs. CHO). MILK had an unclear effect on all other variables. Consumption of 500 mL of milk after repeat sprint cycling had little to no benefit in minimising losses in peak torque or minimising increases in soreness and tiredness and had no effect on serum markers of muscle damage and inflammation.
Soccer-Specific Fatigue and Eccentric Hamstrings Muscle Strength
Greig, Matt; Siegler, Jason C
2009-01-01
Context: Epidemiologic findings of higher incidences of hamstrings muscle strains during the latter stages of soccer match play have been attributed to fatigue. Objective: To investigate the influence of soccer-specific fatigue on the peak eccentric torque of the knee flexor muscles. Design: Descriptive laboratory study. Setting: Controlled laboratory environment. Patients or Other Participants: Ten male professional soccer players (age = 24.7 ± 4.4 years, mass = 77.1 ± 8.3 kg, V̇o2max = 63.0 ± 4.8 mL·kg−1·min−1). Intervention(s): Participants completed an intermittent treadmill protocol replicating the activity profile of soccer match play, with a passive halftime interval. Before exercise and at 15-minute intervals, each player completed isokinetic dynamometer trials. Main Outcome Measure(s): Peak eccentric knee flexor torque was quantified at isokinetic speeds of 180° · s−1, 300° · s−1, and 60° · s−1, with 5 repetitions at each speed. Results: Peak eccentric knee flexor torque at the end of the game (T300eccH105 = 127 ± 25 Nm) and at the end of the passive halftime interval (T300eccH60 = 133 ± 32 Nm) was reduced relative to T300eccH00 (167 ± 35 Nm, P < .01) and T300eccH15 (161 ± 35 Nm, P = .02). Conclusions: Eccentric hamstrings strength decreased as a function of time and after the halftime interval. This finding indicates a greater risk of injuries at these specific times, especially for explosive movements, in accordance with epidemiologic observations. Incorporating eccentric knee flexor exercises into resistance training sessions that follow soccer-specific conditioning is warranted to try to reduce the incidence or recurrence of hamstrings strains. PMID:19295963
Fong, Shirley S M; Chan, Jessie S M; Bae, Young-Hyeon; Yam, Timothy T T; Chung, Louisa M Y; Ma, Ada W W; Kuisma, Raija
2017-01-01
This cross-sectional exploratory study aimed to quantify and compare the axial and appendicular bone mineral density (BMD), muscle mass, and muscle strength of middle-aged practitioners of Ving Tsun (VT; a hard-style Chinese martial art) with those of nonpractitioners.Eighteen VT practitioners (mean age ± standard deviation = 51.8 ± 17.7 years; 12 men and six women) and 36 active controls (mean age ± standard deviation = 58.7 ± 11.0 years; 18 men and 18 women) participated in the study. All participants underwent a 1-day battery of musculoskeletal examinations. The BMD of the total radius, total hip, femoral neck, and lumbar spine was measured using dual-energy X-ray absorptiometry, as was the lean mass of the arm, leg, and trunk. Muscle strength of the upper and lower limbs was assessed using a Jamar dynamometer and an isokinetic dynamometer at 60°/second, respectively.VT-trained participants had a 11.5% higher total radius BMD (P = 0.023), a 17.8% higher leg lean mass (P = 0.014), a 56.4% higher isokinetic body weight-adjusted peak torque of the knee extensors (P < 0.001), a 60.8% higher isokinetic body weight-adjusted peak torque of knee flexors (P < 0.001), and a 31.4% shorter time to reach peak torque in the knee flexors (P = 0.001) than the active controls. No significant differences were found in any of the other musculoskeletal outcomes between the 2 groups (P > 0.05).Middle-aged VT practitioners displayed a higher total radius BMD and leg lean mass and better knee extensor and flexor muscular performances than their healthy active counterparts. Healthcare professionals may consider using this alternative method of training to improve the musculoskeletal health of middle-aged adults.
Amey, David L.; Degner, Michael W.
2002-01-01
A method for reducing the starting time and reducing the peak phase currents for an internal combustion engine that is started using an induction machine starter/alternator. The starting time is reduced by pre-fluxing the induction machine and the peak phase currents are reduced by reducing the flux current command after a predetermined period of time has elapsed and concurrent to the application of the torque current command. The method of the present invention also provides a strategy for anticipating the start command for an internal combustion engine and determines a start strategy based on the start command and the operating state of the internal combustion engine.
Geng, Peng; Tan, Qinming; Zhang, Chunhui; Wei, Lijiang; He, Xianzhong; Cao, Erming; Jiang, Kai
2016-12-01
In recent years, marine auxiliary diesel engine has been widely used to produce electricity in the large ocean-going ship. One of the main technical challenges for ocean-going ship is to reduce pollutant emissions from marine auxiliary diesel engine and to meet the criteria of disposal on ships pollutants of IMO (International Maritime Organization). Different technical changes have been introduced in marine auxiliary diesel engine to apply clean fuels to reduce pollutant emissions. The ultralow sulfur light fuel will be applied in diesel engine for emission reductions in China. This study is aimed to investigate the impact of fuel (ultralow sulfur light fuel) on the combustion characteristic, NOx and green house gas emissions in a marine auxiliary diesel engine, under the 50%-90% engine speeds and the 25%-100% engine torques. The experimental results show that, in the marine auxiliary diesel engine, the cylinder pressure and peak heat release rate increase slightly with the increase of engine torques, while the ignition advances and combustion duration become longer. With the increases of the engine speed and torque, the fuel consumption decreases significantly, while the temperature of the exhaust manifold increases. The NOx emissions increase significantly with the increases of the engine speed and torque. The NO emission increases with the increases of the engine speed and torque, while the NO 2 emission decreases. Meanwhile, the ratio of NO 2 and NO is about 1:1 when the diesel engine operated in the low speed and load, while the ratio increases significantly with the increases of engine speed and torque, due to the increase of the cylinder temperature in the diffusive combustion mode. Moreover, the CO 2 emission increases with the increases of engine speed and torque by the use of ultralow sulfur light fuel. Copyright © 2016. Published by Elsevier B.V.
Z-2 Threaded Insert Design and Testing
NASA Technical Reports Server (NTRS)
Ross, Amy; Rhodes, Richard; Jones, Robert J.; Graziosi, David; Ferl, Jinny; Sweeny, Mitch; Scarborough, Stephen
2016-01-01
NASA's Z-2 prototype space suit contains several components fabricated from an advanced hybrid composite laminate consisting of IM10 carbon fiber and fiber glass. One requirement was to have removable, replaceable helicoil inserts to which other suit components would be fastened. An approach utilizing bonded in inserts with helicoils inside of them was implemented. During initial assembly, cracking sounds were heard followed by the lifting of one of the blind inserts out of its hole when the screws were torqued. A failure investigation was initiated to understand the mechanism of the failure. Ultimately, it was determined that the pre-tension caused by torqueing the fasteners is a much larger force than induced from the pressure loads of the suit which was not considered in the insert design. Bolt tension is determined by dividing the torque on the screw by a k value multiplied by the thread diameter of the bolt. The k value is a factor that accounts for friction in the system. A common value used for k for a non-lubricated screw is 0.2. The k value can go down by as much as 0.1 if the screw is lubricated which means for the same torque, a much larger tension could be placed on the bolt and insert. This paper summarizes the failure investigation that was performed to identify the root cause of the suit failure and details how the insert design was modified to resist a higher pull out tension.
Kobayashi, Yasuto; Ae, Michiyoshi; Miyazaki, Akiyo; Fujii, Norihisa; Iiboshi, Akira; Nakatani, Hideki
2016-09-01
The purpose of this study was to investigate joint kinetics of the throwing arms and role of trunk motion in skilled elementary school boys during an overarm distance throw. Throwing motions of 42 boys from second, fourth, and sixth grade were videotaped with three high-speed cameras operating at 300 fps. Seven skilled boys from each grade were selected on the basis of throwing distance for three-dimensional kinetic analysis. Joint forces, torques, and torque powers of the throwing arm joints were calculated from reconstructed three-dimensional coordinate data smoothed at cut-off frequencies of 10.5-15 Hz and by the inverse dynamics method. Throwing distance and ball velocity significantly increased with school grade. The angular velocity of elbow extension before ball release increased with school grade, although no significant increase between the grades was observed in peak extension torque of elbow joint. The joint torque power of shoulder internal/external rotation tended to increase with school grade. When teaching the overarm throw, elementary school teachers should observe large backward twisting of trunk during the striding phase and should keep in mind that young children, such as second graders (age 8 years), will be unable to effectively utilise shoulder external/internal rotation during the throwing phase.
Effect of gravity-like torque on goal-directed arm movements in microgravity.
Bringoux, L; Blouin, J; Coyle, T; Ruget, H; Mouchnino, L
2012-05-01
Gravitational force level is well-known to influence arm motor control. Specifically, hyper- or microgravity environments drastically change pointing accuracy and kinematics, particularly during initial exposure. These modifications are thought to partly reflect impairment in arm position sense. Here we investigated whether applying normogravitational constraints at joint level during microgravity episodes of parabolic flights could restore movement accuracy equivalent to that observed on Earth. Subjects with eyes closed performed arm reaching movements toward predefined sagittal angular positions in four environment conditions: normogravity, hypergravity, microgravity, and microgravity with elastic bands attached to the arm to mimic gravity-like torque at the shoulder joint. We found that subjects overshot and undershot the target orientations in hypergravity and microgravity, respectively, relative to a normogravity baseline. Strikingly, adding gravity-like torque prior to and during movements performed in microgravity allowed subjects to be as accurate as in normogravity. In the former condition, arm movement kinematics, as notably illustrated by the relative time to peak velocity, were also unchanged relative to normogravity, whereas significant modifications were found in hyper- and microgravity. Overall, these results suggest that arm motor planning and control are tuned with respect to gravitational information issued from joint torque, which presumably enhances arm position sense and activates internal models optimally adapted to the gravitoinertial environment.