NASA Astrophysics Data System (ADS)
Ayu Rahmalia, Diah; Nilamprasasti, Hesti
2017-04-01
We have analyzed the earthquakes data in West Sumatra province to determine peak ground acceleration value. The peak ground acceleration is a parameter that describes the strength of the tremor that ever happened. This paper aims to compare the value of the peak ground acceleration by considering the b-value before and after the Padang earthquake 2009. This research was carried out in stages, starting by taking the earthquake data in West Sumatra province with boundary coordinates 0.923° LU - 2.811° LS and 97.075° - 102.261° BT, before and after the 2009 Padang earthquake with a magnitude ≥ 3 and depth of ≤ 300 km, calculation of the b-value, and ended by creating peak ground acceleration map based on Mc. Guirre empirical formula with Excel and Surfer software. Based on earthquake data from 2002 until before Padang earthquake 2009, the b-value is 0.874 while the b-value after the Padang earthquake in 2009 to 2016 is 0.891. Considering b value, it can be known that peak ground acceleration before and after the 2009 Padang earthquake might be different. Based on the seismic data before 2009, the peak ground acceleration value of West Sumatra province is ranged from 7,002 to 308.875 gal. This value will be compared by the value of the peak ground acceleration after the Padang earthquake in 2009 which ranged from 7,946 to 372,736 gal.
NASA Astrophysics Data System (ADS)
Fnais, M. S.
2014-12-01
The AlKhobar City affected by distant earthquakes from Zagros fold-fault belt of subduction zone. These earthquakes produced great site effects on the sedimentary layers that in turn significantly influenced earthquake ground motions in the area. Mapping of site response using microtremor measurements compared with geological and borehole data of Alkhobar city is the main target of this work. The resonance frequency and their H/V values have been calculated using Nakamura technique through deployed of seismograph instruments at 113 sites in AlKhobar city for different time periods. The recording length was about one hour with sampling frequency of 100 Hz. Most of the measured sites present three peaks for the resonance frequency; the first peak ranges from 0.33 to 1.03 Hz, the second peak ranges from 1.03 to 1.23 Hz, while the third peak ranges from 1.23-1.73. Tests have been conducted to ensure that these peaks are natural in origin. The northern zones of AlKhobar City have lower values of resonance frequency indicating great thickness of sediments. In contrast, the southern parts of the city have higher values of resonance frequency illustrating shallow depths of the bedrock. Furthermore, twenty of boreholes have been conducted through AlKhobar City to different depth. Standard penetration test (SPT) data has been corrected and used to calculate the resonance frequency at their locations. Borehole results clarified that the resonance frequency values range from 0.27 to 1.95 Hz. These results are correlated well with that of the microtremor measurements. Accordingly, the first peak have been interpreted due to the impedance contrast between the limestone and the overlying sediments, while the third peak is originated from a boundary between the upper most surface layer and the underlying sediments. These results must be applied for earthquake risk mitigation in AlKhobar City.
Undrained behavior and shear strength of clean sand containing low-plastic fines
NASA Astrophysics Data System (ADS)
To-Anh Phan, Vu; Hsiao, Darn-Horng
2018-04-01
This study presents experimental tests to understand the undrained behavior of sand containing various fines contents. The specimens were prepared by the wet tamping method. The consolidated undrained triaxial shear tests were carried out by sands mixed with amounts of fines in ranging from 0 to 60%. The results showed that the deviator stress quickly reaches the peak value with an axial strain in a range of 0.5 to 2%, and then, the value drops significantly with further increases in the axial strain, the pore water pressure of all the sand-fines mixtures rapidly increases as the axial strain reaches a value in a range from 1 to 2% and then slowly increases and reaches a stable state when strain is greater than 8%. Peak deviator stress gradually decreases with an increasing fines content from 0 to 40%, thereafter, the peak deviator significantly increases with further increases in the fines content up to 60%, irrespective of confining pressure values using in these tests. Finally, the effective internal friction angles are remarkably greater than the total friction angles for various sand-fines mixtures.
Impact of the definition of peak standardized uptake value on quantification of treatment response.
Vanderhoek, Matt; Perlman, Scott B; Jeraj, Robert
2012-01-01
PET-based treatment response assessment typically measures the change in maximum standardized uptake value (SUV(max)), which is adversely affected by noise. Peak SUV (SUV(peak)) has been recommended as a more robust alternative, but its associated region of interest (ROI(peak)) is not uniquely defined. We investigated the impact of different ROI(peak) definitions on quantification of SUV(peak) and tumor response. Seventeen patients with solid malignancies were treated with a multitargeted receptor tyrosine kinase inhibitor resulting in a variety of responses. Using the cellular proliferation marker 3'-deoxy-3'-(18)F-fluorothymidine ((18)F-FLT), whole-body PET/CT scans were acquired at baseline and during treatment. (18)F-FLT-avid lesions (∼2/patient) were segmented on PET images, and tumor response was assessed via the relative change in SUV(peak). For each tumor, 24 different SUV(peaks) were determined by changing ROI(peak) shape (circles vs. spheres), size (7.5-20 mm), and location (centered on SUV(max) vs. placed in highest-uptake region), encompassing different definitions from the literature. Within each tumor, variations in the 24 SUV(peaks) and tumor responses were measured using coefficient of variation (CV), standardized deviation (SD), and range. For each ROI(peak) definition, a population average SUV(peak) and tumor response were determined over all tumors. A substantial variation in both SUV(peak) and tumor response resulted from changing the ROI(peak) definition. The variable ROI(peak) definition led to an intratumor SUV(peak) variation ranging from 49% above to 46% below the mean (CV, 17%) and an intratumor SUV(peak) response variation ranging from 49% above to 35% below the mean (SD, 9%). The variable ROI(peak) definition led to a population average SUV(peak) variation ranging from 24% above to 28% below the mean (CV, 14%) and a population average SUV(peak) response variation ranging from only 3% above to 3% below the mean (SD, 2%). The size of ROI(peak) caused more variation in intratumor response than did the location or shape of ROI(peak). Population average tumor response was independent of size, shape, and location of ROI(peak). Quantification of individual tumor response using SUV(peak) is highly sensitive to the ROI(peak) definition, which can significantly affect the use of SUV(peak) for assessment of treatment response. Clinical trials are necessary to compare the efficacy of SUV(peak) and SUV(max) for quantification of response to therapy.
Pope, Noah G.; Veirs, Douglas K.; Claytor, Thomas N.
1994-01-01
The specific gravity or solute concentration of a process fluid solution located in a selected structure is determined by obtaining a resonance response spectrum of the fluid/structure over a range of frequencies that are outside the response of the structure itself. A fast fourier transform (FFT) of the resonance response spectrum is performed to form a set of FFT values. A peak value for the FFT values is determined, e.g., by curve fitting, to output a process parameter that is functionally related to the specific gravity and solute concentration of the process fluid solution. Calibration curves are required to correlate the peak FFT value over the range of expected specific gravities and solute concentrations in the selected structure.
Pope, N.G.; Veirs, D.K.; Claytor, T.N.
1994-10-25
The specific gravity or solute concentration of a process fluid solution located in a selected structure is determined by obtaining a resonance response spectrum of the fluid/structure over a range of frequencies that are outside the response of the structure itself. A fast Fourier transform (FFT) of the resonance response spectrum is performed to form a set of FFT values. A peak value for the FFT values is determined, e.g., by curve fitting, to output a process parameter that is functionally related to the specific gravity and solute concentration of the process fluid solution. Calibration curves are required to correlate the peak FFT value over the range of expected specific gravities and solute concentrations in the selected structure. 7 figs.
Zhang, Qi; Li, Wei; Lin, Da-Chao; He, Ning; Duan, Yun
2011-01-30
The aim of this paper is to provide new experimental data of the minimum ignition energy (MIE) of gaseous nitromethane/air mixtures to discuss the explosion pressure and the flame temperature as a function of nitromethane concentration. Observations on the influence of nitromethane concentration on combustion pressure and temperature through the pressure and temperature measure system show that peak temperature (the peak of combustion temperature wave) is always behind peak pressure (the peak of the combustion pressure wave) in arrival time, the peak combustion pressure of nitromethane increases in the range of its volume fraction 10-40% as the concentration of nitromethane increases, and it slightly decreases in the range of 40-50%. The maximum peak pressure is equal to 0.94 MPa and the minimum peak pressure 0.58 MPa. Somewhat similar to the peak pressure, the peak combustion temperature increases with the volume fraction of nitromethane in the range of 10-40%, and slightly decreases in 40-50%. The maximum peak temperature is 1340 °C and the minimum 860 °C. The combustion temperature rise rate increases with the concentration of nitromethane in 10-30%, while decreases in 30-50% and its maximum value of combustion temperature rise rate in 10-50% is 4200 °C/s at the volume fraction of 30%. Influence of the concentration of nitromethane on the combustion pressure rise rate is relatively complicated, and the maximum value of rise rate of combustion pressure wave in 10-50% is 11 MPa/s at the concentration 20%. Copyright © 2010 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Matsukawa, S.; Makino, T.; Mori, S.; Koyama, D.; Takayanagi, S.; Mizuno, K.; Yanagitani, T.; Matsukawa, M.
2017-04-01
The bone fracture healing mechanism of the low-intensity pulsed ultrasound technique is not yet clearly understood. In our previous study, the electrical potentials induced in bone were successfully measured by focusing on piezoelectricity in the MHz range. Bone is composed of collagen and hydroxyapatite and has strong anisotropy. The purpose of this study is to investigate the effects of bone anisotropy on the electrical potentials induced by ultrasound irradiation. For this study, ultrasound bone transducers were fabricated using cortical bovine bone plates as piezoelectric devices. An ultrasound of 7.4 kPapeak-peak (i.e., the peak-to-peak pressure value) was used to irradiate the side surface of each bone plate. Electrical potentials induced in the bone plate were then measured by varying the wave propagation direction in the plate. The peak-to-peak values of these ultrasonically induced electrical potentials were found to vary with changes in the ultrasound propagation direction in the bone sample. The potential was maximized at an inclination of approximately 45° to the bone axis but was minimized around the three orthogonal directions. These maxima and minima ranged from 28 to 33 μVpeak-peak and from 5 to 12 μVpeak-peak, respectively. Additionally, our ultrasound results indicated a change in polarity due to bone anisotropy in the MHz range.
Apparatus and method for processing Korotkov sounds. [for blood pressure measurement
NASA Technical Reports Server (NTRS)
Golden, D. P., Jr.; Hoffler, G. W.; Wolthuis, R. A. (Inventor)
1974-01-01
A Korotkov sound processor, used in a noninvasive automatic blood measuring system where the brachial artery is occluded by an inflatable cuff, is disclosed. The Korotkoff sound associated with the systolic event is determined when the ratio of the absolute value of a voltage signal, representing Korotkov sounds in the range of 18 to 26 Hz to a maximum absolute peak value of the unfiltered signals, first equals or exceeds a value of 0.45. Korotkov sound associated with the diastolic event is determined when a ratio of the voltage signal of the Korotkov sounds in the range of 40 to 60 Hz to the absolute peak value of such signals within a single measurement cycle first falls below a value of 0.17. The processor signals the occurrence of the systolic and diastolic events and these signals can be used to control a recorder to record pressure values for these events.
Computer simulation of storm runoff for three watersheds in Albuquerque, New Mexico
Knutilla, R.L.; Veenhuis, J.E.
1994-01-01
Rainfall-runoff data from three watersheds were selected for calibration and verification of the U.S. Geological Survey's Distributed Routing Rainfall-Runoff Model. The watersheds chosen are residentially developed. The conceptually based model uses an optimization process that adjusts selected parameters to achieve the best fit between measured and simulated runoff volumes and peak discharges. Three of these optimization parameters represent soil-moisture conditions, three represent infiltration, and one accounts for effective impervious area. Each watershed modeled was divided into overland-flow segments and channel segments. The overland-flow segments were further subdivided to reflect pervious and impervious areas. Each overland-flow and channel segment was assigned representative values of area, slope, percentage of imperviousness, and roughness coefficients. Rainfall-runoff data for each watershed were separated into two sets for use in calibration and verification. For model calibration, seven input parameters were optimized to attain a best fit of the data. For model verification, parameter values were set using values from model calibration. The standard error of estimate for calibration of runoff volumes ranged from 19 to 34 percent, and for peak discharge calibration ranged from 27 to 44 percent. The standard error of estimate for verification of runoff volumes ranged from 26 to 31 percent, and for peak discharge verification ranged from 31 to 43 percent.
Relaxation and turbulence effects on sonic boom signatures
NASA Technical Reports Server (NTRS)
Pierce, Allan D.; Sparrow, Victor W.
1992-01-01
The rudimentary theory of sonic booms predicts that the pressure signatures received at the ground begin with an abrupt shock, such that the overpressure is nearly abrupt. This discontinuity actually has some structure, and a finite time is required for the waveform to reach its peak value. This portion of the waveform is here termed the rise phase, and it is with this portion that this presentation is primarily concerned. Any time characterizing the duration of the rise phase is loosely called the 'rise time.' Various definitions are used in the literature for this rise time. In the present discussion the rise time can be taken as the time for the waveform to rise from 10 percent of its peak value to 90 percent of its peak value. The available data on sonic booms that appears in the open literature suggests that typical values of shock over-pressure lie in the range of 30 Pa to 200 Pa, typical values of shock duration lie in the range of 150 ms to 250 ms, and typical values of the rise time lie in the range of 1 ms to 5 ms. The understanding of the rise phase of sonic booms is important because the perceived loudness of a shock depends primarily on the structure of the rise phase. A longer rise time typically implies a less loud shock. A primary question is just what physical mechanisms are most important for the determination of the detailed structure of the rise phase.
Kim, Young-sun; Kim, Byoung-Gie; Rhim, Hyunchul; Bae, Duk-Soo; Lee, Jeong-Won; Kim, Tae-Joong; Choi, Chel Hun; Lee, Yoo-Young; Lim, Hyo Keun
2014-11-01
To determine whether semiquantitative perfusion magnetic resonance (MR) imaging parameters are associated with therapeutic effectiveness of MR imaging-guided high-intensity focused ultrasound ( HIFU high-intensity focused ultrasound ) ablation of uterine fibroids and which semiquantitative perfusion parameters are significant with regard to treatment efficiency. This study was approved by the institutional review board, and informed consent was obtained from all subjects. Seventy-seven women (mean age, 43.3 years) with 119 fibroids (mean diameter, 7.5 cm) treated with MR imaging-guided HIFU high-intensity focused ultrasound ablation were analyzed. The correlation between semiquantitative perfusion MR parameters (peak enhancement, relative peak enhancement, time to peak, wash-in rate, washout rate) and heating and ablation efficiencies (lethal thermal dose volume based on MR thermometry and nonperfused volume based on immediate contrast-enhanced image divided by intended treatment volume) were evaluated by using a linear mixed model on a per-fibroid basis. The specific value of the significant parameter that had a substantial effect on treatment efficiency was determined. The mean peak enhancement, relative peak enhancement, time to peak, wash-in rate, and washout rate of the fibroids were 1293.1 ± 472.8 (range, 570.2-2477.8), 171.4% ± 57.2 (range, 0.6%-370.2%), 137.2 seconds ± 119.8 (range, 20.0-300.0 seconds), 79.5 per second ± 48.2 (range, 12.5-236.7 per second), and 11.4 per second ± 10.1 (range, 0-39.3 per second), respectively. Relative peak enhancement was found to be independently significant for both heating and ablation efficiencies (B = -0.002, P < .001 and B = -0.003, P = .050, respectively). The washout rate was significantly associated with ablation efficiency (B = -0.018, P = .043). Both efficiencies showed the most abrupt transitions at 220% of relative peak enhancement. Relative peak enhancement at semiquantitative perfusion MR imaging was significantly associated with treatment efficiency of MR imaging-guided HIFU high-intensity focused ultrasound ablation of uterine fibroids, and a value of 220% or less is suggested as a screening guideline for more efficient treatment.
Lawlor, Sean M.
2004-01-01
Stream-restoration projects using natural stream designs typically are based on channel configurations that can accommodate a wide range of streamflow and sediment-transport conditions without excessive erosion or deposition. Bankfull discharge is an index of streamflow considered to be closely related to channel shape, size, and slope (channel morphology). Because of the need for more information about the relation between channel morphology and bankfull discharge, the U.S. Geological Survey (USGS), in cooperation with the Montana Department of Transportation and the U.S. Department of Agriculture-Lolo National Forest, conducted a study to collect channel-morphology and bankfull-discharge data at gaged sites and use these data to improve current (2004) methods of estimation of bankfull discharge and various design-peak discharges at ungaged sites. This report presents channel-morphology characteristics, bankfull discharge, and various design-peak discharges for 41 sites in western Montana. Channel shape, size, and slope and bankfull discharge were determined at 41 active or discontinued USGS streamflow-gaging sites in western Montana. The recurrence interval for the bankfull discharge for this study ranged from 1.0 to 4.4 years with a median value of 1.5 years. The relations between channel-morphology characteristics and various design-peak discharges were examined using regression analysis. The analyses showed that the only characteristics that were significant for all peak discharges were either bankfull width or bankfull cross-sectional area. Bankfull discharge at ungaged sites in most of the study area can be estimated by application of a multiplier after determining the 2-year peak discharge at the ungaged site. The multiplier, which is the ratio of bankfull discharge to the 2-year peak discharge determined at the 41 sites, ranged from 0.21 to 3.7 with a median value of 0.84. Regression relations between bankfull discharge and drainage area and between bankfull width and drainage area were examined for three ranges of mean annual precipitation. The results of the regression analyses indicated that both drainage area and mean annual precipitation were significantly related (p values less than 0.05) to bankfull discharge.
The Crab pulsar light curve in the soft gamma ray range: FIGARO II results
NASA Technical Reports Server (NTRS)
Massaro, E.; Agrinier, B.; Barouch, E.; Comte, R.; Costa, E.; Cusumano, G. C.; Gerardi, G.; Lemoine, D.; Mandrou, P.; Masnou, J. L.
1992-01-01
The FIGARO II experiment (a large area, balloon borne, crystal scintillator detector working from 0.15 to 4.3 MeV) observed the Crab pulsar on 1990 Jul. 9 for about seven hours. The study of the pulse profile confirms some structures detected with a low significance during the shorter observation of 1986, and adds new important elements to the picture. In particular, between the two main peaks, two secondary peaks appear centered at phase values 0.1 and 0.3, in the energy range 0.38 to 0.49 MeV; in the same energy range, a spectral feature at 0.44 MeV, interpreted as a redshifted positron annihilation line, was observed during the same balloon flight in the phase interval including the second main peak and the neighboring secondary peak. If the phase interval considered is extended to include also the other secondary peak, the significance of the spectral line appears to increase.
Asquith, William H.; Cleveland, Theodore G.; Roussel, Meghan C.
2011-01-01
Estimates of peak and time of peak streamflow for small watersheds (less than about 640 acres) in a suburban to urban, low-slope setting are needed for drainage design that is cost-effective and risk-mitigated. During 2007-10, the U.S. Geological Survey (USGS), in cooperation with the Harris County Flood Control District and the Texas Department of Transportation, developed a method to estimate peak and time of peak streamflow from excess rainfall for 10- to 640-acre watersheds in the Houston, Texas, metropolitan area. To develop the method, 24 watersheds in the study area with drainage areas less than about 3.5 square miles (2,240 acres) and with concomitant rainfall and runoff data were selected. The method is based on conjunctive analysis of rainfall and runoff data in the context of the unit hydrograph method and the rational method. For the unit hydrograph analysis, a gamma distribution model of unit hydrograph shape (a gamma unit hydrograph) was chosen and parameters estimated through matching of modeled peak and time of peak streamflow to observed values on a storm-by-storm basis. Watershed mean or watershed-specific values of peak and time to peak ("time to peak" is a parameter of the gamma unit hydrograph and is distinct from "time of peak") of the gamma unit hydrograph were computed. Two regression equations to estimate peak and time to peak of the gamma unit hydrograph that are based on watershed characteristics of drainage area and basin-development factor (BDF) were developed. For the rational method analysis, a lag time (time-R), volumetric runoff coefficient, and runoff coefficient were computed on a storm-by-storm basis. Watershed-specific values of these three metrics were computed. A regression equation to estimate time-R based on drainage area and BDF was developed. Overall arithmetic means of volumetric runoff coefficient (0.41 dimensionless) and runoff coefficient (0.25 dimensionless) for the 24 watersheds were used to express the rational method in terms of excess rainfall (the excess rational method). Both the unit hydrograph method and excess rational method are shown to provide similar estimates of peak and time of peak streamflow. The results from the two methods can be combined by using arithmetic means. A nomograph is provided that shows the respective relations between the arithmetic-mean peak and time of peak streamflow to drainage areas ranging from 10 to 640 acres. The nomograph also shows the respective relations for selected BDF ranging from undeveloped to fully developed conditions. The nomograph represents the peak streamflow for 1 inch of excess rainfall based on drainage area and BDF; the peak streamflow for design storms from the nomograph can be multiplied by the excess rainfall to estimate peak streamflow. Time of peak streamflow is readily obtained from the nomograph. Therefore, given excess rainfall values derived from watershed-loss models, which are beyond the scope of this report, the nomograph represents a method for estimating peak and time of peak streamflow for applicable watersheds in the Houston metropolitan area. Lastly, analysis of the relative influence of BDF on peak streamflow is provided, and the results indicate a 0:04log10 cubic feet per second change of peak streamflow per positive unit of change in BDF. This relative change can be used to adjust peak streamflow from the method or other hydrologic methods for a given BDF to other BDF values; example computations are provided.
Experiments on Laser Beam Jitter Control with Applications to a Shipboard Free Electron Laser
2007-12-01
factor one half converts from peak to rms values. This psd was then converted to units of ( mrms /s2)2/Hz by dividing by the square of the given voltage...the root mean square value in units of mrms for a given frequency range. (3) Vibration Measurement Results. The total displacement from 1-400 Hz...The mass may represent, for example, a component of an FEL. The support, s, is harmonically excited at a peak displacement amplitude of xs. The
Experiment on the concrete slab for floor vibration evaluation of deteriorated building
NASA Astrophysics Data System (ADS)
Hong, S. U.; Na, J. H.; Kim, S. H.; Lee, Y. T.
2014-08-01
Damages from noise and vibration are increasing every year, and most of which are noises between floors in deteriorated building caused by floor impact sound. In this study, the floor vibration of the deteriorated buildings constructed with the concrete slabs of thickness no more than 150 mm was evaluated by the vibration impact sound. This highly reliable study was conducted to assess floor vibration according with the serviceability evaluation standard of Reiher / Meister and Koch and vibration evaluation standard of ISO and AIJ. Designed pressure for the concrete slab sample of floor vibration assessment was 24MPa, and the sample was manufactured pursuant to KS F 2865 and JIS A 1440-2 with size of 3200 mm × 3200 mm × 140 mm. Tests were conducted twice with accelerometers, and Fast Fourier Transform was performed for comparative analysis by the vibration assessment criteria. The peak displacement from Test 1 was in the range of 0.00869 - 0.02540 mm; the value of peak frequency ranged from 18 to 27 Hz, and the average value was 22Hz. The peak acceleration value from Test 2 was in the range of 0.47 - 1.07 % g; the value of peak frequency was 18.5 - 22.57 Hz, and the average was 21Hz. The vibration was apparently recognizable in most cases according to the Reiher/Meister standard. In case of Koch graph for the damage assessment of the structure, the vibration was at the medium level and causes no damage to the building structure. The measured vibration results did not exceed the damage limit or serviceability limit of building according to the vibration assessment criteria of ISO and residential assessment guidelines provided by Architectural Institute of Japan (AIJ).
MODELING TIME DISPERSION DUE TO OPTICAL PATH LENGTH DIFFERENCES IN SCINTILLATION DETECTORS*
Moses, W.W.; Choong, W.-S.; Derenzo, S.E.
2015-01-01
We characterize the nature of the time dispersion in scintillation detectors caused by path length differences of the scintillation photons as they travel from their generation point to the photodetector. Using Monte Carlo simulation, we find that the initial portion of the distribution (which is the only portion that affects the timing resolution) can usually be modeled by an exponential decay. The peak amplitude and decay time depend both on the geometry of the crystal, the position within the crystal that the scintillation light originates from, and the surface finish. In a rectangular parallelpiped LSO crystal with 3 mm × 3 mm cross section and polished surfaces, the decay time ranges from 10 ps (for interactions 1 mm from the photodetector) up to 80 ps (for interactions 50 mm from the photodetector). Over that same range of distances, the peak amplitude ranges from 100% (defined as the peak amplitude for interactions 1 mm from the photodetector) down to 4% for interactions 50 mm from the photodetector. Higher values for the decay time are obtained for rough surfaces, but the exact value depends on the simulation details. Estimates for the decay time and peak amplitude can be made for different cross section sizes via simple scaling arguments. PMID:25729464
Modeling Time Dispersion Due to Optical Path Length Differences in Scintillation Detectors
Moses, W. W.; Choong, W. -S.; Derenzo, S. E.
2014-08-20
In this paper, we characterize the nature of the time dispersion in scintillation detectors caused by path length differences of the scintillation photons as they travel from their generation point to the photodetector. Using Monte Carlo simulation, we find that the initial portion of the distribution (which is the only portion that affects the timing resolution) can usually be modeled by an exponential decay. The peak amplitude and decay time depend both on the geometry of the crystal, the position within the crystal that the scintillation light originates from, and the surface finish. In a rectangular parallelpiped LSO crystal withmore » 3 mm × 3 mm cross section and polished surfaces, the decay time ranges from 10 ps (for interactions 1 mm from the photodetector) up to 80 ps (for interactions 50 mm from the photodetector). Over that same range of distances, the peak amplitude ranges from 100% (defined as the peak amplitude for interactions 1 mm from the photodetector) down to 4% for interactions 50 mm from the photodetector. Higher values for the decay time are obtained for rough surfaces, but the exact value depends on the simulation details. Finally, estimates for the decay time and peak amplitude can be made for different cross section sizes via simple scaling arguments.« less
Inlet Flow Characteristics During Rapid Maneuvers for an F/A-18A Airplane
NASA Technical Reports Server (NTRS)
Steenken, William G.; Williams, John G.; Walsh, Kevin R.
1999-01-01
The F404-GE-400 engine powered F/A-18A High Alpha Research Vehicle (HARV) was used to examine the characteristics of inlet airflow during rapid aircraft maneuvers. A study of the degree of similarity between inlet data obtained during rapid aircraft maneuvers and inlet data obtained at steady aerodynamic attitudes was conducted at the maximum engine airflow of approximately 145 Ibm/sec using a computer model that was generated from inlet data obtained during steady aerodynamic maneuvers. Results show that rapid-maneuver inlet recoveries agreed very well with the recoveries obtained at equivalent stabilized angle-of-attack conditions. The peak dynamic circumferential distortion values obtained during rapid maneuvers agreed within 0.01 units of distortion over the 10 - 38 degree angle of attack range with the values obtained during steady aerodynamic maneuvers while similar agreement was found for the peak dynamic radial distortion values up to 29 degrees angle-of-attack. Exceedences of the rapid-maneuver peak dynamic circumferential distortion values relative to the peak distortion model values at steady attitudes occurred only at low or negative angles of attack and were inconsequential from an engine-stability assessment point of view. The results of this study validate the current industry practice of testing at steady aerodynamic conditions to characterize inlet recovery and peak dynamic distortion levels.
Techniques for Computation of Frequency Limited H∞ Norm
NASA Astrophysics Data System (ADS)
Haider, Shafiq; Ghafoor, Abdul; Imran, Muhammad; Fahad Mumtaz, Malik
2018-01-01
Traditional H ∞ norm depicts peak system gain over infinite frequency range, but many applications like filter design, model order reduction and controller design etc. require computation of peak system gain over specific frequency interval rather than infinite range. In present work, new computationally efficient techniques for computation of H ∞ norm over frequency limited interval are proposed. Proposed techniques link norm computation with maximum singular value of the system in limited frequency interval. Numerical examples are incorporated to validate the proposed concept.
Measurement and Modeling of Acoustic Fields in a Gel Phantom at High Intensities
NASA Astrophysics Data System (ADS)
Canney, Michael S.; Bailey, Michael R.; Khokhlova, Vera A.; Crum, Lawrence A.
2006-05-01
The goal of this work was to compare measured and numerically predicted HIFU pressure waveforms in water and a tissue-mimicking phantom. Waveforms were measured at the focus of a 2-MHz HIFU transducer with a fiber optic hydrophone. The transducer was operated with acoustic powers ranging from 2W to 300W. A KZK-type equation was used for modeling the experimental conditions. Strongly asymmetric nonlinear waves with peak positive pressure up to 80 MPa and peak negative pressure up to 20 MPa were measured in water, while waves up to 50 MPa peak positive pressure and 15 MPa peak negative pressure were measured in tissue phantoms. The values of peak negative pressure corresponded well with numerical simulations and were significantly smaller than predicted by linear extrapolation from low-level measurements. The values of peak positive pressures differed only at high levels of excitation where bandwidth limitations of the hydrophone failed to fully capture the predicted sharp shock fronts.
Lu, He-qi; Wei, Bing; Chao, Zhi-mao; Deng, Yun-long; Cheng, Yu-biao; Wang, Ke-lin; Zhou, Yan-hua; Yang, Kun-jie; Zhang, Hai-zhong; Cheng, Zhao-huan
2007-08-01
To study the endogenous hormone of testosterone and cortisol that secretes volume and rhythm in sports fatigued human bodies and animals. To determine secretory volume and rhythm in sports fatigued human bodies and animals when Shixiang yaofa's drug are used. Radio-immunity method was used to determine secretory volume and rhythm in sports fatigued human bodies and animals and to analyze secretory volume and rhythm. According to the secretory volume and rhythm of testosterone and cortisol, the Shixiang Yaofa's drugs were used. Doses: wenyang jihuo bead 10 g/sack 2 sack, ziyin xiuyang capsule 0.5 g/pill 8 pill pd in human bodies for 28 days. Wenyang jihuo bead 10 g x kg(-1) of crude drug, ziyin xiuyang capsule 4 g x kg(-1) of crude drug pd for hight doses in animals. Other groups for low doses 5 g x kg(-1) and 2 g x kg(-1) of crude drug pd for 15 days. The blood samples were collected for determination. (1) In human bodies the peak value of testosterone was appeared in 8:00 and valley value was appeared in 18:00, ranges: 176.93-281.73 x 10(-5) mg x L(-1). The peak value of cortisol was appeared in 8:00 and valley value was appeared in 22:00, ranges: 1.31-16.13 x 10(-3) mg x L(-1). In the same condition, the mouse peak value of testosterone was appeared in 20:00 and valley value was appeared in 0:00, ranges: (0.56 x 10(-5) - 124.0 x 10(-5)) mg x L(-1). The rhythm in animals was compatible with human bodies, howerer, the peak value was delayed for 12 hours. (2) The testosterone was step up and the cortisol was cut down in sports fatigued human bodies and animals when shixiang yaofa's drug were used (P < 0.05, P < 0.01). The secretion of testosterone and cortisol in sports fatigued human bodies and animals are existed conclusive biologic rhythm. The secretory volume can be available accommodation by shixiang yaofa's drugs.
NASA Astrophysics Data System (ADS)
Pubby, Kunal; Narang, Sukhleen Bindra; Kaur, Prabhjyot; Chawla, S. K.
2017-05-01
Hexaferrite nano-particles of stoichiometric composition {{Sr}}{({{CoZr}})_x}{{F}}{{{e}}_{12 - 2x}}{{{O}}_{19}}, with x = 0.0, 0.2, 0.4, 0.6, 0.8, 1.0 were prepared using sol-gel auto-combustion route owing to its advantages such as low sintering temperature requirement, homogeneity and uniformity of grains. Tartaric acid as a fuel was utilized to complete the chemical reaction. The goal of this study is to analyse the effect of co-substitution of cobalt and zirconium on the electromagnetic and absorption properties of pure {{SrF}}{{{e}}_{12}}{{{O}}_{19}} hexaferrite. The properties were measured on the rectangular pellets of thickness 2.5 mm for K-frequency band using Vector Network Analyzer. The doping of Co-Zr has resulted in increase in real as well as imaginary parts of permittivity. The values of real permittivity lie in the range 3.6-7.0 for all the composition. The real part of permeability remains in range 0.7-1.6 in the studied frequency band for all the samples and shows slightly increasing trend with frequency. The maximum values of dielectric loss tangent peak (3.04) and magnetic loss tangent peak (2.34), among all the prepared compositions, have been observed for composition x = 0.2. Compositions with x = 0.6 and x = 0.0 also have high dielectric and magnetic loss peaks. Dielectric loss peaks are attributed to dielectric resonance and magnetic loss peaks are attributed to natural resonance. Experimentally determined reflection loss results show that all six compositions of prepared series have high values of absorption to propose them as single-layer absorbers in 18-26.5 GHz frequency range. The composition with x = 0.2 has maximum absorption capacity with reflection loss peak of -37.2 dB at 24.3 GHz frequency. The undoped composition also has high absorption peak (-25.46 dB), but -10 dB absorption bandwidth is minimum (2.2 GHz) out of the present series. Maximum absorption bandwidth is obtained for x = 1.0 (4.1 GHz). Other doped compositions also have high absorption bandwidth in range 3.4-3.9 GHz. The results of absorption were related to the dielectric phase angle to conclude that high electro-magnetic losses are dominant factor in deciding absorption properties of ferrites in comparison to impedance matching.
NASA Astrophysics Data System (ADS)
Lievens, Klaus; Van Nimmen, Katrien; Lombaert, Geert; De Roeck, Guido; Van den Broeck, Peter
2016-09-01
In civil engineering and architecture, the availability of high strength materials and advanced calculation techniques enables the construction of slender footbridges, generally highly sensitive to human-induced excitation. Due to the inherent random character of the human-induced walking load, variability on the pedestrian characteristics must be considered in the response simulation. To assess the vibration serviceability of the footbridge, the statistics of the stochastic dynamic response are evaluated by considering the instantaneous peak responses in a time range. Therefore, a large number of time windows are needed to calculate the mean value and standard deviation of the instantaneous peak values. An alternative method to evaluate the statistics is based on the standard deviation of the response and a characteristic frequency as proposed in wind engineering applications. In this paper, the accuracy of this method is evaluated for human-induced vibrations. The methods are first compared for a group of pedestrians crossing a lightly damped footbridge. Small differences of the instantaneous peak value were found by the method using second order statistics. Afterwards, a TMD tuned to reduce the peak acceleration to a comfort value, was added to the structure. The comparison between both methods in made and the accuracy is verified. It is found that the TMD parameters are tuned sufficiently and good agreements between the two methods are found for the estimation of the instantaneous peak response for a strongly damped structure.
Circadian rhythm of blood and urinary copper in presumably healthy subjects of vegetarian food habit
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bhattacharya, R.D.
Circadian rhythm of blood and urinary copper has been studied in presumably healthy subjects of a particular ethnic group in India who are vegetarians. A definite 24-hr variation has been observed for both blood and urinary copper. The peak for blood copper was 1500 hr and the lowest value was 0600 hr, with values of 0.185 mg/100 ml and 0.160 mg/100 ml respectively. The urinary peak and trough occurred at 0600 and 0300 hr, respectively. Remarkably higher 24-hr copper excretion values were noted (64.49 ..mu..g/day) with a range of 15-100 ..mu..g/day. The blood level of copper (0.134 mg/100 ml) remainedmore » within the range reported. One subject out of 25 deviated from the group with respect to circadian phasing and amplitude to urinary copper excretion. 20 references.« less
Automatic Locking of Laser Frequency to an Absorption Peak
NASA Technical Reports Server (NTRS)
Koch, Grady J.
2006-01-01
An electronic system adjusts the frequency of a tunable laser, eventually locking the frequency to a peak in the optical absorption spectrum of a gas (or of a Fabry-Perot cavity that has an absorption peak like that of a gas). This system was developed to enable precise locking of the frequency of a laser used in differential absorption LIDAR measurements of trace atmospheric gases. This system also has great commercial potential as a prototype of means for precise control of frequencies of lasers in future dense wavelength-division-multiplexing optical communications systems. The operation of this system is completely automatic: Unlike in the operation of some prior laser-frequency-locking systems, there is ordinarily no need for a human operator to adjust the frequency manually to an initial value close enough to the peak to enable automatic locking to take over. Instead, this system also automatically performs the initial adjustment. The system (see Figure 1) is based on a concept of (1) initially modulating the laser frequency to sweep it through a spectral range that includes the desired absorption peak, (2) determining the derivative of the absorption peak with respect to the laser frequency for use as an error signal, (3) identifying the desired frequency [at the very top (which is also the middle) of the peak] as the frequency where the derivative goes to zero, and (4) thereafter keeping the frequency within a locking range and adjusting the frequency as needed to keep the derivative (the error signal) as close as possible to zero. More specifically, the system utilizes the fact that in addition to a zero crossing at the top of the absorption peak, the error signal also closely approximates a straight line in the vicinity of the zero crossing (see Figure 2). This vicinity is the locking range because the linearity of the error signal in this range makes it useful as a source of feedback for a proportional + integral + derivative control scheme that constantly adjusts the frequency in an effort to drive the error to zero. When the laser frequency deviates from the midpeak value but remains within the locking range, the magnitude and sign of the error signal indicate the amount of detuning and the control circuitry adjusts the frequency by what it estimates to be the negative of this amount in an effort to bring the error to zero.
Aerobic power and peak power of elite America's Cup sailors.
Neville, Vernon; Pain, Matthew T G; Folland, Jonathan P
2009-05-01
Big-boat yacht racing is one of the only able bodied sporting activities where standing arm-cranking ('grinding') is the primary physical activity. However, the physiological capabilities of elite sailors for standing arm-cranking have been largely unreported. The purpose of the study was to assess aerobic parameters, VO(2peak) and onset of blood lactate (OBLA), and anaerobic performance, torque-crank velocity and power-crank velocity relationships and therefore peak power (P (max)) and optimum crank-velocity (omega(opt)), of America's Cup sailors during standing arm-cranking. Thirty-three elite professional sailors performed a step test to exhaustion, and a subset of ten grinders performed maximal 7 s isokinetic sprints at different crank velocities, using a standing arm-crank ergometer. VO(2peak) was 4.7 +/- 0.5 L/min (range 3.6-5.5 L/min) at a power output of 332 +/- 44 W (range 235-425 W). OBLA occurred at a power output of 202 +/- 31 W (61% of W(max)) and VO(2) of 3.3 +/- 0.4 L/min (71% of VO(2peak)). The torque-crank velocity relationship was linear for all participants (r = 0.9 +/- 0.1). P (max) was 1,420 +/- 37 W (range 1,192-1,617 W), and omega(opt) was 125 +/- 6 rpm. These data are among the highest upper-body anaerobic and aerobic power values reported. The unique nature of these athletes, with their high fat-free mass and specific selection and training for standing arm cranking, likely accounts for the high values. The influence of crank velocity on peak power implies that power production during on-board 'grinding' may be optimised through the use of appropriate gear-ratios and the development of efficient gear change mechanisms.
Höchsmann, Christoph; Rossmeissl, Anja; Baumann, Sandra; Infanger, Denis; Schmidt-Trucksäss, Arno
2018-03-15
To examine cardiorespiratory exertion during mini trampoline exercises of different intensities in both endurance-trained athletes and overweight-obese adults. Physically healthy participants (Group A: normal-weight, endurance-trained athletes; Group B: inactive, overweight-obese adults) participated in two measurement appointments and three training sessions in between appointments, in which participants familiarized themselves with the use of the mini trampoline and the execution of the exercises. The primary outcome was the ⩒O 2peak for each of the six mini trampoline exercises relative to the ⩒O 2peak as established during an all-out exercise test on a bike ergometer during the first measurement appointment. Secondary outcomes were average ⩒O 2 as well as maximum and average heart rate. The six mini trampoline exercises generated ⩒O 2peak values between 42% and 81% in the endurance-trained athletes and between 58% and 87% in the overweight-obese participants, both in relation to the bike ergometer ⩒O 2peak . Average ⩒O 2 values ranged from 35% to 69% (endurance-trained athletes) and from 48% to 71% (overweight-obese participants), depending on exercise. Average heart rate likewise lay in a range that can be categorized as moderate-to-vigorous aerobic exercise for both groups. A moderate-to-strong correlation (0.658 to 0.875, depending on exercise) between bike ergometer ⩒O 2peak and mini trampoline ⩒O 2peak was found for all six exercises. Mini trampoline exercise has the potential to produce training intensities that concur with established exercise guidelines. The exercise intensity is self-adjusting and allows for an effective and safe workout for different users with a wide range of fitness levels.
Perry, Charles A.; Wolock, David M.; Artman, Joshua C.
2004-01-01
Streamflow statistics of flow duration and peak-discharge frequency were estimated for 4,771 individual locations on streams listed on the 1999 Kansas Surface Water Register. These statistics included the flow-duration values of 90, 75, 50, 25, and 10 percent, as well as the mean flow value. Peak-discharge frequency values were estimated for the 2-, 5-, 10-, 25-, 50-, and 100-year floods. Least-squares multiple regression techniques were used, along with Tobit analyses, to develop equations for estimating flow-duration values of 90, 75, 50, 25, and 10 percent and the mean flow for uncontrolled flow stream locations. The contributing-drainage areas of 149 U.S. Geological Survey streamflow-gaging stations in Kansas and parts of surrounding States that had flow uncontrolled by Federal reservoirs and used in the regression analyses ranged from 2.06 to 12,004 square miles. Logarithmic transformations of climatic and basin data were performed to yield the best linear relation for developing equations to compute flow durations and mean flow. In the regression analyses, the significant climatic and basin characteristics, in order of importance, were contributing-drainage area, mean annual precipitation, mean basin permeability, and mean basin slope. The analyses yielded a model standard error of prediction range of 0.43 logarithmic units for the 90-percent duration analysis to 0.15 logarithmic units for the 10-percent duration analysis. The model standard error of prediction was 0.14 logarithmic units for the mean flow. Regression equations used to estimate peak-discharge frequency values were obtained from a previous report, and estimates for the 2-, 5-, 10-, 25-, 50-, and 100-year floods were determined for this report. The regression equations and an interpolation procedure were used to compute flow durations, mean flow, and estimates of peak-discharge frequency for locations along uncontrolled flow streams on the 1999 Kansas Surface Water Register. Flow durations, mean flow, and peak-discharge frequency values determined at available gaging stations were used to interpolate the regression-estimated flows for the stream locations where available. Streamflow statistics for locations that had uncontrolled flow were interpolated using data from gaging stations weighted according to the drainage area and the bias between the regression-estimated and gaged flow information. On controlled reaches of Kansas streams, the streamflow statistics were interpolated between gaging stations using only gaged data weighted by drainage area.
Baumgart, Julia Kathrin; Brurok, Berit; Sandbakk, Øyvind
2018-01-01
Peak oxygen uptake (VO2peak) in Paralympic sitting sports athletes represents their maximal ability to deliver energy aerobically in an upper-body mode, with values being influenced by sex, disability-related physiological limitations, sport-specific demands, training status and how they are tested. To identify VO2peak values in Paralympic sitting sports, examine between-sports differences and within-sports variations in VO2peak and determine the influence of sex, age, body-mass, disability and test-mode on VO2peak. Systematic literature review and meta-analysis. PubMed, CINAHL, SPORTDiscusTM and EMBASE were systematically searched in October 2016 using relevant medical subject headings, keywords and a Boolean. Studies that assessed VO2peak values in sitting sports athletes with a disability in a laboratory setting were included. Data was extracted and pooled in the different sports disciplines, weighted by the Dersimonian and Laird random effects approach. Quality of the included studies was assessed with a modified version of the Downs and Black checklist by two independent reviewers. Meta-regression and pooled-data multiple regression analyses were performed to assess the influence of sex, age, body-mass, disability, test mode and study quality on VO2peak. Of 6542 retrieved articles, 57 studies reporting VO2peak values in 14 different sitting sports were included in this review. VO2peak values from 771 athletes were used in the data analysis, of which 30% participated in wheelchair basketball, 27% in wheelchair racing, 15% in wheelchair rugby and the remaining 28% in the 11 other disciplines. Fifty-six percent of the athletes had a spinal cord injury and 87% were men. Sports-discipline-averaged VO2peak values ranged from 2.9 L∙min-1 and 45.6 mL∙kg-1∙min-1 in Nordic sit skiing to 1.4 L∙min-1 and 17.3 mL∙kg-1∙min-1 in shooting and 1.3 L∙min-1 and 18.9 mL∙kg-1∙min-1 in wheelchair rugby. Large within-sports variation was found in sports with few included studies and corresponding low sample sizes. The meta-regression and pooled-data multiple regression analyses showed that being a man, having an amputation, not being tetraplegic, testing in a wheelchair ergometer and treadmill mode, were found to be favorable for high absolute and body-mass normalized VO2peak values. Furthermore, high body mass was favourable for high absolute VO2peak values and low body mass for high body-mass normalized VO2peak values. The highest VO2peak values were found in Nordic sit skiing, an endurance sport with continuously high physical efforts, and the lowest values in shooting, a sport with low levels of displacement, and in wheelchair rugby where mainly athletes with tetraplegia compete. However, VO2peak values need to be interpreted carefully in sports-disciplines with few included studies and large within-sports variation. Future studies should include detailed information on training status, sex, age, test mode, as well as the type and extent of disability in order to more precisely evaluate the effect of these factors on VO2peak.
Brurok, Berit; Sandbakk, Øyvind
2018-01-01
Background Peak oxygen uptake (VO2peak) in Paralympic sitting sports athletes represents their maximal ability to deliver energy aerobically in an upper-body mode, with values being influenced by sex, disability-related physiological limitations, sport-specific demands, training status and how they are tested. Objectives To identify VO2peak values in Paralympic sitting sports, examine between-sports differences and within-sports variations in VO2peak and determine the influence of sex, age, body-mass, disability and test-mode on VO2peak. Design Systematic literature review and meta-analysis. Data sources PubMed, CINAHL, SPORTDiscusTM and EMBASE were systematically searched in October 2016 using relevant medical subject headings, keywords and a Boolean. Eligibility criteria Studies that assessed VO2peak values in sitting sports athletes with a disability in a laboratory setting were included. Data synthesis Data was extracted and pooled in the different sports disciplines, weighted by the Dersimonian and Laird random effects approach. Quality of the included studies was assessed with a modified version of the Downs and Black checklist by two independent reviewers. Meta-regression and pooled-data multiple regression analyses were performed to assess the influence of sex, age, body-mass, disability, test mode and study quality on VO2peak. Results Of 6542 retrieved articles, 57 studies reporting VO2peak values in 14 different sitting sports were included in this review. VO2peak values from 771 athletes were used in the data analysis, of which 30% participated in wheelchair basketball, 27% in wheelchair racing, 15% in wheelchair rugby and the remaining 28% in the 11 other disciplines. Fifty-six percent of the athletes had a spinal cord injury and 87% were men. Sports-discipline-averaged VO2peak values ranged from 2.9 L∙min-1 and 45.6 mL∙kg-1∙min-1 in Nordic sit skiing to 1.4 L∙min-1 and 17.3 mL∙kg-1∙min-1 in shooting and 1.3 L∙min-1 and 18.9 mL∙kg-1∙min-1 in wheelchair rugby. Large within-sports variation was found in sports with few included studies and corresponding low sample sizes. The meta-regression and pooled-data multiple regression analyses showed that being a man, having an amputation, not being tetraplegic, testing in a wheelchair ergometer and treadmill mode, were found to be favorable for high absolute and body-mass normalized VO2peak values. Furthermore, high body mass was favourable for high absolute VO2peak values and low body mass for high body-mass normalized VO2peak values. Conclusion The highest VO2peak values were found in Nordic sit skiing, an endurance sport with continuously high physical efforts, and the lowest values in shooting, a sport with low levels of displacement, and in wheelchair rugby where mainly athletes with tetraplegia compete. However, VO2peak values need to be interpreted carefully in sports-disciplines with few included studies and large within-sports variation. Future studies should include detailed information on training status, sex, age, test mode, as well as the type and extent of disability in order to more precisely evaluate the effect of these factors on VO2peak. PMID:29474386
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bergfeld, D.; Nabelek, P.I.; Labotka, T.C.
1992-01-01
The Kingston Peak Formation forms part of the Panamint Mountains, California, metamorphic core-complex. Peak tremolite-grade metamorphism as exhibited in Wildrose Canyon occurred in the Jurassic; a retrograde thermal event may have occurred in the Cretaceous. The formation consists dominantly of interbedded siliceous limestones and graphitic calcareous schists. Stable isotopic analysis shows two distinct groups of data. delta O-18 values of calcite from the limestones range between 15.3 and 17.3[per thousand], probably reflecting their original Proterozoic depositional values. Likewise the delta C-13 values are also unshifted, ranging from +1% to +3.8%o. In contrast, delta O-18 values of calcite from the schistsmore » are for the most part > 20[per thousand]. These high values could reflect the original depostional conditions; however, they may be due to equilibration with silicate minerals which range from 14.9 to 17.9[per thousand]. Overall, the combined oxygen and carbon isotopic data indicate that most isotopic changes can be explained by closed-system equilibration. Only a limited amount of interaction with externally-derived fluids during metamorphism is evident in the isotopic data. The interaction may have been confined to vicinities of faults and fractures which are common in Wildrose Canyon.« less
Treatment of Glioma Using neuroArm Surgical System
2016-01-01
The use of robotic technology in the surgical treatment of brain tumour promises increased precision and accuracy in the performance of surgery. Robotic manipulators may allow superior access to narrow surgical corridors compared to freehand or conventional neurosurgery. This paper reports values and ranges of tool-tissue interaction forces during the performance of glioma surgery using an MR compatible, image-guided neurosurgical robot called neuroArm. The system, capable of microsurgery and stereotaxy, was used in the surgical resection of glioma in seven cases. neuroArm is equipped with force sensors at the end-effector allowing quantification of tool-tissue interaction forces and transmits force of dissection to the surgeon sited at a remote workstation that includes a haptic interface. Interaction forces between the tool tips and the brain tissue were measured for each procedure, and the peak forces were quantified. Results showed maximum and minimum peak force values of 2.89 N (anaplastic astrocytoma, WHO grade III) and 0.50 N (anaplastic oligodendroglioma, WHO grade III), respectively, with the mean of peak forces varying from case to case, depending on type of the glioma. Mean values of the peak forces varied in range of 1.27 N (anaplastic astrocytoma, WHO grade III) to 1.89 N (glioblastoma with oligodendroglial component, WHO grade IV). In some cases, ANOVA test failed to reject the null hypothesis of equality in means of the peak forces measured. However, we could not find a relationship between forces exerted to the pathological tissue and its size, type, or location. PMID:27314044
Lafon, Belen; Henin, Simon; Huang, Yu; Friedman, Daniel; Melloni, Lucia; Thesen, Thomas; Doyle, Werner; Buzsáki, György; Devinsky, Orrin; Parra, Lucas C; Liu, Anli
2018-02-28
It has come to our attention that we did not specify whether the stimulation magnitudes we report in this Article are peak amplitudes or peak-to-peak. All references to intensity given in mA in the manuscript refer to peak-to-peak amplitudes, except in Fig. 2, where the model is calibrated to 1 mA peak amplitude, as stated. In the original version of the paper we incorrectly calibrated the computational models to 1 mA peak-to-peak, rather than 1 mA peak amplitude. This means that we divided by a value twice as large as we should have. The correct estimated fields are therefore twice as large as shown in the original Fig. 2 and Supplementary Figure 11. The corrected figures are now properly calibrated to 1 mA peak amplitude. Furthermore, the sentence in the first paragraph of the Results section 'Intensity ranged from 0.5 to 2.5 mA (current density 0.125-0.625 mA mA/cm 2 ), which is stronger than in previous reports', should have read 'Intensity ranged from 0.5 to 2.5 mA peak to peak (peak current density 0.0625-0.3125 mA/cm 2 ), which is stronger than in previous reports.' These errors do not affect any of the Article's conclusions.
Impact of particle concentration and out-of-range sizes on the measurements of the LISST
NASA Astrophysics Data System (ADS)
Zhao, Lin; Boufadel, Michel C.; King, Thomas; Robinson, Brian; Conmy, Robyn; Lee, Kenneth
2018-05-01
The instrument LISST (laser in situ scattering and transmissiometry) has been widely used for measuring the size of oil droplets in relation to oil spills and sediment particles. Major concerns associated with using the instrument include the impact of high concentrations and/or out-of-range particle (droplet) sizes on the LISST reading. These were evaluated experimentally in this study using monosized microsphere particles. The key findings include: (1) When high particle concentration reduced the optical transmission (OT) to below 30%, the measured peak value tended to underestimate the true peak value, and the accuracy of the LISST decreased by ~8% to ~28%. The maximum concentration to reach the 30% OT was about 50% of the theoretical values, suggesting a lower concentration level should be considered during the instrument deployment. (2) The out-of-range sizes of particles affected the LISST measurements when the sizes were close to the LISST measurement range. Fine below-range sizes primarily affected the data in the lowest two bins of the LISST with >75% of the volume at the smallest bin. Large out-of-range particles affected the sizes of the largest 8–10 bins only when very high concentration was present. The out-of-range particles slightly changed the size distribution of the in-range particles, but their concentration was conserved. An approach to interpret and quantify the effects of the out-of-range particles on the LISST measurement was proposed.
Light scattering from normal and cervical cancer cells.
Lin, Xiaogang; Wan, Nan; Weng, Lingdong; Zhou, Yong
2017-04-20
The light scattering characteristic plays a very important role in optic imaging and diagnostic applications. For optical detection of the cell, cell scattering characteristics have an extremely vital role. In this paper, we use the finite-difference time-domain (FDTD) algorithm to simulate the propagation and scattering of light in biological cells. The two-dimensional scattering cell models were set up based on the FDTD algorithm. The cell models of normal cells and cancerous cells were established, and the shapes of organelles, such as mitochondria, were elliptical. Based on these models, three aspects of the scattering characteristics were studied. First, the radar cross section (RCS) distribution curves of the corresponding cell models were calculated, then corresponding relationships between the size and the refractive index of the nucleus and light scattering information were analyzed in the three periods of cell canceration. The values of RCS increase positively with the increase of the nucleo-cytoplasmic ratio in the cancerous process when the scattering angle ranges from 0° to 20°. Second, the effect of organelles in the scattering was analyzed. The peak value of the RCS of cells with mitochondria is higher than the cells without mitochondria when the scattering angle ranges from 20° to 180°. Third, we demonstrated that the influence of cell shape is important, and the impact was revealed by the two typical ideal cells: round cells and oval cells. When the scattering angle ranges from 0° to 80°, the peak values and the frequencies of the appearance of the peaks from the two models are roughly similar. It can be concluded that: (1) the size of the nuclei and the change of the refractive index of cells have a certain impact on light scattering information of the whole cell; (2) mitochondria and other small organelles contribute to the cell light scattering characteristics in the larger scattering angle area; and (3) the change of the cell shape significantly influences the value of scattering peak and the deviation of scattering peak position. The results of the numerical simulation will guide subsequent experiments and early diagnosis of cervical cancer.
Sugiura, Yoshito; Hatanaka, Yasuhiko; Arai, Tomoaki; Sakurai, Hiroaki; Kanada, Yoshikiyo
2016-04-01
We aimed to investigate whether a linear regression formula based on the relationship between joint torque and angular velocity measured using a high-speed video camera and image measurement software is effective for estimating 1 repetition maximum (1RM) and isometric peak torque in knee extension. Subjects comprised 20 healthy men (mean ± SD; age, 27.4 ± 4.9 years; height, 170.3 ± 4.4 cm; and body weight, 66.1 ± 10.9 kg). The exercise load ranged from 40% to 150% 1RM. Peak angular velocity (PAV) and peak torque were used to estimate 1RM and isometric peak torque. To elucidate the relationship between force and velocity in knee extension, the relationship between the relative proportion of 1RM (% 1RM) and PAV was examined using simple regression analysis. The concordance rate between the estimated value and actual measurement of 1RM and isometric peak torque was examined using intraclass correlation coefficients (ICCs). Reliability of the regression line of PAV and % 1RM was 0.95. The concordance rate between the actual measurement and estimated value of 1RM resulted in an ICC(2,1) of 0.93 and that of isometric peak torque had an ICC(2,1) of 0.87 and 0.86 for 6 and 3 levels of load, respectively. Our method for estimating 1RM was effective for decreasing the measurement time and reducing patients' burden. Additionally, isometric peak torque can be estimated using 3 levels of load, as we obtained the same results as those reported previously. We plan to expand the range of subjects and examine the generalizability of our results.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, D. Y., E-mail: cdy7659@126.com; Nanjing University of posts and Telecommunications, Nanjing 210046; Sun, Y.
We have investigated carrier transport in SiO{sub 2}/nc-Si/SiO{sub 2} multi-layers by room temperature current-voltage measurements. Resonant tunneling signatures accompanied by current peaks are observed. Carrier transport in the multi-layers were analyzed by plots of ln(I/V{sup 2}) as a function of 1/V and ln(I) as a function of V{sup 1/2}. Results suggest that besides films quality, nc-Si and barrier sub-layer thicknesses are important parameters that restrict carrier transport. When thicknesses are both small, direct tunneling dominates carrier transport, resonant tunneling occurs only at certain voltages and multi-resonant tunneling related current peaks can be observed but with peak to valley current ratiomore » (PVCR) values smaller than 1.5. When barrier thickness is increased, trap-related and even high field related tunneling is excited, causing that multi-current peaks cannot be observed clearly, only one current peak with higher PVCR value of 7.7 can be observed. While if the thickness of nc-Si is large enough, quantum confinement is not so strong, a broad current peak with PVCR value as high as 60 can be measured, which may be due to small energy difference between the splitting energy levels in the quantum dots of nc-Si. Size distribution in a wide range may cause un-controllability of the peak voltages.« less
Single- and Double-Strand Breaks of Dry DNA Exposed to Protons at Bragg-Peak Energies.
Souici, Mounir; Khalil, Talat T; Muller, Dominique; Raffy, Quentin; Barillon, Rémi; Belafrites, Abdelfettah; Champion, Christophe; Fromm, Michel
2017-01-26
Ultrathin layers (<20 nm) of pBR322 plasmid DNA were deposited onto 2.5 μm thick polyester films and exposed to proton Bragg-peak energies (90-3000 keV) at various fluences. A quantitative analysis of radio-induced DNA damage is reported here in terms of single- and double-strand breaks (SSB and DSB, respectively). The corresponding yields as well as G-values and the cross sections exhibit fairly good agreement with the rare available data, stemming from close experimental conditions, namely, based on α particle irradiation. SSB/DSB rates appear to be linear when plotted against linear energy transfer (LET) in the whole energy range studied. All the data present a maximum in the 150-200 keV energy range; as for LET, it peaks at 90 keV. We also show that fragmentation starts to be significant for proton fluences greater than 1 × 10 11 cm -2 at the Bragg-peak energies. Finally, we determine the average proton track radial extension, r max , corresponding to an occupation probability of 100% DSB in the Bragg-peak region. The r max values determined are in excellent agreement with the radial extensions of proton tracks determined by simulation approaches in water. When plotted as a function of LET, both SSB and DSB cross sections bend back at high LETs.
NASA Astrophysics Data System (ADS)
Ogden, Fred L.
2016-11-01
Tropical Storm Erika was a weakly organized tropical storm when its center of circulation passed more than 150 km north of the island of Dominica on August 27, 2015. Hurricane hunter flights had difficulty finding the center of circulation as the storm encountered a high shear environment. Satellite and radar observations showed gyres imbedded within the broader circulation. Radar observations from Guadeloupe show that one of these gyres formed in convergent mid-level flow triggered by orographic convection over the island of Dominica. Gauge-adjusted radar rainfall data indicated between 300 and 750 mm of rainfall on Dominica, most of it over a four hour period. The result was widespread flooding, destruction of property, and loss of life. The extremity of the rainfall on steep watersheds covered with shallow soils was hypothesized to result in near-equilibrium runoff conditions where peak runoff rates equal the watershed-average peak rainfall rate minus a small constant loss rate. Rain gauge adjusted radar rainfall estimates and indirect peak discharge (IPD) measurements from 16 rivers at watershed areas ranging from 0.9 to 31.4 km2 using the USGS Slope-Area method allowed testing of this hypothesis. IPD measurements were compared against the global envelope of maximum observed flood peaks versus drainage area and against simulations using the U.S. Army Corps of Engineers Gridded Surface/Subsurface Hydrologic Analysis (GSSHA) model to detect landslide-affected peak flows. Model parameter values were estimated from the literature. Reasonable agreement was found between GSSHA simulated peak flows and IPD measurements in some watersheds. Results showed that landslide dam failure affected peak flows in 5 of the 16 rivers, with peak flows significantly greater than the envelope curve values for the flood of record for like-sized watersheds on the planet. GSSHA simulated peak discharges showed that the remaining 11 peak flow values were plausible. Simulations of an additional 24 watersheds ranging in size from 2.2 to 75.4 km2 provided confirmation that the IPD measurements varied from 40 to nearly 100% of the envelope curve value depending on storm-total rainfall. Results presented in this paper support the hypothesis that on average, the peak discharges scaled linearly with drainage area, and the constant of proportionality was equivalent to 134 mm h-1, or a unit discharge of 37.22 m3 s-1 km-2. The results also indicate that after the available watershed storage was filled after approximately 450-500 mm of rain fell, runoff efficiencies exceeded 50-60%, and peak runoff rates were more than 80% of the peak rainfall rate minus a small constant loss rate of 20 mm h-1. These findings have important implications for design of resilient infrastructure, and means that rainfall rate was the primary determinant of peak flows once the available storage was filled in the absences of landslide dam failure.
Estimation of ground motion parameters
Boore, David M.; Joyner, W.B.; Oliver, A.A.; Page, R.A.
1978-01-01
Strong motion data from western North America for earthquakes of magnitude greater than 5 are examined to provide the basis for estimating peak acceleration, velocity, displacement, and duration as a function of distance for three magnitude classes. A subset of the data (from the San Fernando earthquake) is used to assess the effects of structural size and of geologic site conditions on peak motions recorded at the base of structures. Small but statistically significant differences are observed in peak values of horizontal acceleration, velocity and displacement recorded on soil at the base of small structures compared with values recorded at the base of large structures. The peak acceleration tends to b3e less and the peak velocity and displacement tend to be greater on the average at the base of large structures than at the base of small structures. In the distance range used in the regression analysis (15-100 km) the values of peak horizontal acceleration recorded at soil sites in the San Fernando earthquake are not significantly different from the values recorded at rock sites, but values of peak horizontal velocity and displacement are significantly greater at soil sites than at rock sites. Some consideration is given to the prediction of ground motions at close distances where there are insufficient recorded data points. As might be expected from the lack of data, published relations for predicting peak horizontal acceleration give widely divergent estimates at close distances (three well known relations predict accelerations between 0.33 g to slightly over 1 g at a distance of 5 km from a magnitude 6.5 earthquake). After considering the physics of the faulting process, the few available data close to faults, and the modifying effects of surface topography, at the present time it would be difficult to accept estimates less than about 0.8 g, 110 cm/s, and 40 cm, respectively, for the mean values of peak acceleration, velocity, and displacement at rock sites within 5 km of fault rupture in a magnitude 6.5 earthquake. These estimates can be expected to change as more data become available.
Słonina, Dorota; Biesaga, Beata; Swakoń, Jan; Kabat, Damian; Grzanka, Leszek; Ptaszkiewicz, Marta; Sowa, Urszula
2014-11-01
The aim of the study was to determine the relative biological effectiveness (RBE) of a 60-MeV proton radiotherapy beam at the Institute of Nuclear Physics, Polish Academy of Sciences (IFJ PAN) in Kraków, the first one to operate in Poland. RBE was assessed at the surviving fractions (SFs) of 0.01, 0.1, and 0.37, for normal human fibroblasts from three cancer patients. The cells were irradiated near the Bragg peak of the pristine beam and at three depths within a 28.4-mm spread-out Bragg peak (SOBP). Reference radiation was provided by 6-MV X-rays. The mean RBE value at SF = 0.01 for fibroblasts irradiated near the Bragg peak of pristine beam ranged between 1.06 and 1.15. The mean RBE values at SF = 0.01 for these cells exposed at depths of 2, 15, and 27 mm of the SOBP ranged between 0.95-1.00, 0.97-1.02, and 1.05-1.11, respectively. A trend was observed for RBE values to increase with survival level and with depth in the SOBP: at SF = 0.37 and at the depth of 27 mm, RBE values attained their maximum (1.19-1.24). The RBE values estimated at SF = 0.01 using normal human fibroblasts for the 60-MeV proton radiotherapy beam at the IFJ PAN in Kraków are close to values of 1.0 and 1.1, used in clinical practice.
NASA Technical Reports Server (NTRS)
Jain, A. (Inventor)
1978-01-01
Significant height information of ocean waves, or peaks of rough terrain is obtained by compressing the radar signal over different widths of the available chirp or Doppler bandwidths, and cross-correlating one of these images with each of the others. Upon plotting a fixed (e.g., zero) component of the cross-correlation values as the spacing is increased over some empirically determined range, the system is calibrated. To measure height with the system, a spacing value is selected and a cross-correlation value is determined between two intensity images at a selected frequency spacing. The measured height is the slope of the cross-correlation value used. Both electronic and optical radar signal data compressors and cross-correlations are disclosed for implementation of the system.
Hong, Cheng William; Mamidipalli, Adrija; Hooker, Jonathan C.; Hamilton, Gavin; Wolfson, Tanya; Chen, Dennis H.; Dehkordy, Soudabeh Fazeli; Middleton, Michael S.; Reeder, Scott B.; Loomba, Rohit; Sirlin, Claude B.
2017-01-01
Background Proton density fat fraction (PDFF) estimation requires spectral modeling of the hepatic triglyceride (TG) signal. Deviations in the TG spectrum may occur, leading to bias in PDFF quantification. Purpose To investigate the effects of varying six-peak TG spectral models on PDFF estimation bias. Study Type Retrospective secondary analysis of prospectively acquired clinical research data. Population Forty-four adults with biopsy-confirmed nonalcoholic steatohepatitis. Field Strength/Sequence Confounder-corrected chemical-shift-encoded 3T MRI (using a 2D multiecho gradient-recalled echo technique with magnitude reconstruction) and MR spectroscopy. Assessment In each patient, 61 pairs of colocalized MRI-PDFF and MRS-PDFF values were estimated: one pair used the standard six-peak spectral model, the other 60 were six-peak variants calculated by adjusting spectral model parameters over their biologically plausible ranges. MRI-PDFF values calculated using each variant model and the standard model were compared, and the agreement between MRI-PDFF and MRS-PDFF was assessed. Statistical Tests MRS-PDFF and MRI-PDFF were summarized descriptively. Bland–Altman (BA) analyses were performed between PDFF values calculated using each variant model and the standard model. Linear regressions were performed between BA biases and mean PDFF values for each variant model, and between MRI-PDFF and MRS-PDFF. Results Using the standard model, mean MRS-PDFF of the study population was 17.9±8.0% (range: 4.1–34.3%). The difference between the highest and lowest mean variant MRI-PDFF values was 1.5%. Relative to the standard model, the model with the greatest absolute BA bias overestimated PDFF by 1.2%. Bias increased with increasing PDFF (P < 0.0001 for 59 of the 60 variant models). MRI-PDFF and MRS-PDFF agreed closely for all variant models (R2=0.980, P < 0.0001). Data Conclusion Over a wide range of hepatic fat content, PDFF estimation is robust across the biologically plausible range of TG spectra. Although absolute estimation bias increased with higher PDFF, its magnitude was small and unlikely to be clinically meaningful. Level of Evidence 3 Technical Efficacy Stage 2 PMID:28851124
NASA Technical Reports Server (NTRS)
Niedra, Janis M.; Schwarze, Gene E.
1999-01-01
100 kHz magnetization properties of sample transverse magnetically annealed, cobalt-based amorphous and iron-based nanocrystalline tape wound magnetic cores are presented over the temperature range of -150 C to 150 C, at selected values of B(sub peak). Frequency resolved characteristics are given over the range of 50 kHz to 1 MHz, but at B(sub peak) = 0.1 T and 50 C only. Basic exciting winding current and induced voltage data were taken on bare toroidal cores, in a standard type measurement setup. A linear permeability model, which represents the core by a parallel L-R circuit, is used to interpret and present the magnetization characteristics and several figures of merit applicable to inductor materials are reviewed. The 100 kHz permeability thus derived decreases with increasing temperature for the Fe-based, nanocrystalline material, but increases roughly linearly with temperature for the two Co-based materials, as long as B(sub peak) is sufficiently low to avoid saturation effects. Due to the high permeabilities, rather low values of the 'quality factor' Q, from about 20 to below unity, were obtained over the frequency range of 50 kHz to 1 MHz (50 C, B(sub peak) = 0.1 T). Therefore these cores must be gapped in order to make up high Q or high current inductors. However, being rugged, low core loss materials with flat B-H loop characteristics, they may provide new solutions to specialty inductor applications.
NASA Astrophysics Data System (ADS)
Khalil, A. A. I.; Morsy, M. A.; El-Deen, H. Z.
2017-11-01
Series of manganese-co-precipitated poly (vinyl alcohol) (PVA) polymer were quantitatively and qualitatively analyzed using laser ablation system (LAS) based on double-pulse laser induced breakdown spectroscopy (DP-LIBS) and electron paramagnetic resonance (EPR) spectroscopy. The collinear nanosecond laser beams of 266 and 1064 nm were optimized to focus on the surface of the PVA polymer target. Both laser beams were employed to estimate the natural properties of the excited Mn-PVA plasma, such as electron number density (Ne), electron temperature (Te), and Mn concentration. Individual transition lines of manganese (Mn), carbon (C), lithium (Li), hydrogen (H) and oxygen (O) atoms are identified based on the NIST spectral database. The results show better responses with DP-LIBS than the single-pulse laser induced breakdown spectroscopy (SP-LIBS). On the other hand, the EPR investigation shows characteristic broad peak of Mn-nano-particles (Mn-NPs) in the range of quantum dots of superparamagnetic materials. The line width (peak-to-peak, ΔHpp) and g-value of the observed Mn-EPR peak are ∼20 mT and 2.0046, respectively. The intensities of Mn-emission line at a wavelength 403.07 nm and the Mn-EPR absorption peak were used to accurate quantify the Mn-content in the polymer matrix. The results produce linear trends within the studied concentration range with regression coefficient (R2) value of ∼0.99, and limit of detection (LOD) of 0.026 mol.% and 0.016 mol.%, respectively. The LOD values are at a fold change of about -0.2 of the studied lowest mol.%. The proposed protocols of trace element detection are of significant advantage and can be applied to the other metal analysis.
Thermal sterilization of heat-sensitive products using high-temperature short-time sterilization.
Mann, A; Kiefer, M; Leuenberger, H
2001-03-01
High-temperature short-time (HTST) sterilization with a continuous-flow sterilizer, developed for this study, was evaluated. The evaluation was performed with respect to (a) the chemical degradation of two heat-sensitive drugs in HTST range (140-160 degrees C) and (b) the microbiological effect of HTST sterilization. Degradation kinetics of two heat-sensitive drugs showed that a high peak temperature sterilization process resulted in less chemical degradation for the same microbiological effect than a low peak temperature process. Both drugs investigated could be sterilized with acceptable degradation at HTST conditions. For the evaluation of the microbiological effect, Bacillus stearothermophilus ATCC 7953 spores were used as indicator bacteria. Indicator spore kinetics (D(T), z value, k, and E(a)), were determined in the HTST range. A comparison between the Bigelow model (z value concept) and the Arrhenius model, used to describe the temperature coefficient of the microbial inactivation, demonstrated that the Bigelow model is more accurate in prediction of D(T) values in the HTST range. The temperature coefficient decreased with increasing temperature. The influence of Ca(2+) ions and pH value on the heat resistance of the indicator spores, which is known under typical sterilization conditions, did not change under HTST conditions.
Estimation of alga growth stage and lipid content growth rate
NASA Technical Reports Server (NTRS)
Embaye, Tsegereda N. (Inventor); Trent, Jonathan D. (Inventor)
2012-01-01
Method and system for estimating a growth stage of an alga in an ambient fluid. Measured light beam absorption or reflection values through or from the alga and through an ambient fluid, in each of two or more wavelength sub-ranges, are compared with reference light beam absorption values for corresponding wavelength sub-ranges for in each alga growth stage to determine (1) which alga growth stage, if any, is more likely and (2) whether estimated lipid content of the alga is increasing or has peaked. Alga growth is preferably terminated when lipid content has approximately reached a maximum value.
Remittance spectroscopy of human skin in vivo.
Geyer, A; Vilser, W; Karte, K; Wollina, U
1996-08-01
The skin is an easily accessible organ on which non-invasive examination methods can be applied. Recently spectroscopic methods have been introduced in characterization of skin under physiological and pathological conditions. To examine remittance spectroscopic qualities of human skin in vivo and to clarify the influence of selected test conditions, a single-beam spectrometer MCS 410 (Carl Zeiss, Jena, Germany) has been used. Remittance spectra readings were performed in 35 volunteers. Wavelength ranged from 362 nm to 780 nm. Individual remittance values and their standard deviations were obtained from 20 readings under standardized test conditions. The effect of pressure, rubbing, cooling, washing, greasing and degreasing on average remittance values was investigated. Statistical analysis was done with paired Student's f-test and Fisher's test. Pressure increased remittance values over a wide range of wavelength, peaking at 518 nm. Greasing and degreasing modified spectral remittance of shorter wavelength peaking around 362 nm. Rubbing and cooling did not induce significant variations of spectral remittance of skin. Spectral remittance provides an individual profile in human skin, which may be influenced by pressure and greasing/ degreasing. To establish standardized test conditions with a narrow range of intra-individual variation these items have to be kept constant.
Kirkham, Amy A; Pauhl, Katherine E; Elliott, Robyn M; Scott, Jen A; Doria, Silvana C; Davidson, Hanan K; Neil-Sztramko, Sarah E; Campbell, Kristin L; Camp, Pat G
2015-01-01
To determine the utility of equations that use the 6-minute walk test (6MWT) results to estimate peak oxygen uptake ((Equation is included in full-text article.)o2) and peak work rate with chronic obstructive pulmonary disease (COPD) patients in a clinical setting. This study included a systematic review to identify published equations estimating peak (Equation is included in full-text article.)o2 and peak work rate in watts in COPD patients and a retrospective chart review of data from a hospital-based pulmonary rehabilitation program. The following variables were abstracted from the records of 42 consecutively enrolled COPD patients: measured peak (Equation is included in full-text article.)o2 and peak work rate achieved during a cycle ergometer cardiopulmonary exercise test, 6MWT distance, age, sex, weight, height, forced expiratory volume in 1 second, forced vital capacity, and lung diffusion capacity. Estimated peak (Equation is included in full-text article.)o2 and peak work rate were estimated from 6MWT distance using published equations. The error associated with using estimated peak (Equation is included in full-text article.)o2 or peak work to prescribe aerobic exercise intensities of 60% and 80% was calculated. Eleven equations from 6 studies were identified. Agreement between estimated and measured values was poor to moderate (intraclass correlation coefficients = 0.11-0.63). The error associated with using estimated peak (Equation is included in full-text article.)o2 or peak work rate to prescribe exercise intensities of 60% and 80% of measured values ranged from mean differences of 12 to 35 and 16 to 47 percentage points, respectively. There is poor to moderate agreement between measured peak (Equation is included in full-text article.)o2 and peak work rate and estimations from equations that use 6MWT distance, and the use of the estimated values for prescription of aerobic exercise intensity would result in large error. Equations estimating peak (Equation is included in full-text article.)o2 and peak work rate are of low utility for prescribing exercise intensity in pulmonary rehabilitation programs.
Statistics of Dark Matter Halos from Gravitational Lensing.
Jain; Van Waerbeke L
2000-02-10
We present a new approach to measure the mass function of dark matter halos and to discriminate models with differing values of Omega through weak gravitational lensing. We measure the distribution of peaks from simulated lensing surveys and show that the lensing signal due to dark matter halos can be detected for a wide range of peak heights. Even when the signal-to-noise ratio is well below the limit for detection of individual halos, projected halo statistics can be constrained for halo masses spanning galactic to cluster halos. The use of peak statistics relies on an analytical model of the noise due to the intrinsic ellipticities of source galaxies. The noise model has been shown to accurately describe simulated data for a variety of input ellipticity distributions. We show that the measured peak distribution has distinct signatures of gravitational lensing, and its non-Gaussian shape can be used to distinguish models with different values of Omega. The use of peak statistics is complementary to the measurement of field statistics, such as the ellipticity correlation function, and is possibly not susceptible to the same systematic errors.
Sica, S; Rutella, S; Di Mario, A; Salutari, P; Rumi, C; Ortu la Barbera, E; Etuk, B; Menichella, G; D'Onofrio, G; Leone, G
1996-08-01
Recombinant human granulocyte colony-stimulating factor (rhG-CSF) 16 micrograms/kg/day was given to 9 healthy donors to recruit hemopoietic progenitors (HP) for allogeneic transplantation or donor leukocyte infusion. rhG-CSF was administered s.c. for 5 days. No side effects were encountered except for moderate bone pain and lumbago. Mobilization was effective, reaching a peak median value of 187 x 10(3) CD34+ cells/ml (range 51.2-1127) and 2170 x 10(3) colony-forming units-granulocyte macrophage (CFU-GM)/ml (range 1138-4190). Peak values were obtained at a median of 4 days of rhG-CSF and represented, respectively, a 13-fold and a 37-fold increase from baseline values (p = 0.0007 and p = 0.006). White blood cell (WBC) counts increased 6-fold from baseline values (p < 0.0007) and reached a median peak of 34 x 10(6)/ml (23.5-59). Polymorphonuclear (PMN), and mononuclear (MNC) cells increased 10-fold and 2-fold, respectively (p = 0.0039 and p = 0.0026) and reached a median peak of 32.1 x 10(6)/ml (18.2-52) and 4.42 x 10(6)/ml (3.14-12.42). Absolute lymphocyte and monocyte counts increased at peak day in all donors 1.5-fold and 5.7-fold from baseline values (p = 0.0017 and p = 0.0018). In 7 of 9 donors, lymphocyte subsets were analyzed in detail. CD3+ and CD19+ lymphocytes increased 1.5-fold and 3-fold, respectively (p = 0.032 for both). NK and activated T lymphocytes doubled at a median of 4 days of rhG-CSF (p = 0.032 and p = NS, respectively). Similar changes were observed in lymphocytes collected in leukapheresis product. T helper and T suppressor subsets displayed a similar increase. Thus, besides the anticipated priming effect on HP and PMN, rhG-CSF in healthy donors produced an unexpected and still unexplained modification of lymphocyte subsets in peripheral blood.
Relations for estimating unit-hydrograph parameters in New Mexico
Waltemeyer, Scott D.
2001-01-01
Data collected from 20 U.S. Geological Survey streamflow-gaging stations, most of which were operated in New Mexico between about 1969 and 1977, were used to define hydrograph characteristics for small New Mexico streams. Drainage areas for the gaging stations ranged from 0.23 to 18.2 square miles. Observed values for the hydrograph characteristics were determined for 87 of the most significant rainfall-runoff events at these gaging stations and were used to define regional regression relations with basin characteristics. Regional relations defined lag time (tl), time of concentration (tc), and time to peak (tp) as functions of stream length and basin shape. The regional equation developed for time of concentration for New Mexico agrees well with the Kirpich equation developed for Tennessee. The Kirpich equation is based on stream length and channel slope, whereas the New Mexico equation is based on stream length and basin shape. Both equations, however, underestimate tc when applied to larger basins where tc is greater than about 2 hours. The median ratio between tp and tc for the observed data was 0.66, which equals the value (0.67) recommended by the Natural Resources Conservation Service (formerly the Soil Conservation Service). However, the median ratio between tl and tc was only 0.42, whereas the commonly used ratio is 0.60. A relation also was developed between unit-peak discharge (qu) and time of concentration. The unit-peak discharge relation is similar in slope to the Natural Resources Conservation Service equation, but the equation developed for New Mexico in this study produces estimates of qu that range from two to three times as large as those estimated from the Natural Resources Conservation Service equation. An average value of 833 was determined for the empirical constant Kp. A default value of 484 has been used by the Natural Resources Conservation Service when site-specific data are not available. The use of a lower value of Kp in calculations generally results in a lower peak discharge. A relation between the empirical constant Kp and average channel slope was defined in this study. The predicted Kp values from the equation ranged from 530 to 964 for the 20 flood-hydrograph gaging stations. The standard error of estimate for the equation is 36 percent.
CATALOG AND STATISTICAL STUDY OF X-RAY SELECTED BL LACERTAE OBJECTS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kapanadze, Bidzina Z., E-mail: bidzina_kapandaze@iliauni.edu.ge
2013-02-01
This paper presents a catalog of 312 X-ray selected BL Lacerate objects (XBLs), optically identified through the end of 2011. It contains the names from different surveys, equatorial coordinates, redshifts, multifrequency flux values, and luminosities for each source. In addition, the different characteristics of XBLs are statistically investigated (redshift, radio/optical/X-ray luminosities, central black hole (BH) mass, synchrotron peak frequency, broadband spectral indices, optical flux variability). Their values are collected through an extensive bibliographic and database search or calculated by us. The redshifts range from 0.031 to 0.702 with a maximum of the distribution at z = 0.223. The 1.4 GHzmore » luminosities of XBLs log {nu}L{sub {nu}} {approx} 39-42 erg s{sup -1} while optical V and X-ray 0.1-2.4 keV bands show log {nu}L{sub {nu}} {approx} 43-46 erg s{sup -1}. The XBL hosts are elliptical galaxies with effective radii r{sub eff} = 3.2625.40 kpc and ellipticities, in = 0.040.52. Their R-band absolute magnitudes M{sub R} range from -21.11 mag to -24.86 mag with a mean value of -22.83 mag. The V - R indices of the hosts span from 0.61 to 1.52 and reveal a fourth-degree polynomial relationship with z that enables us to evaluate the redshifts of five sources whose V - R indices were determined from the observations but whose irredshifts values are either not found or not confirmed. The XBL nuclei show a wider range of 7.31 mag for M{sub R} with the highest luminosity corresponding to M{sub R} = -27.24 mag. The masses of central BHs are found in the interval log M{sub BH} = 7.39-9.30 solar masses (with distribution maximum at log M{sub BH}/M{sub Sun} = 8.30). The synchrotron peak frequencies are spread over the range log {nu}{sub peak} = 14.56-19.18 Hz with a peak of the distribution at log {nu}{sub peak} = 16.60 Hz. The broadband radio-to-optical ({alpha}{sub ro}), optical-to-X-ray ({alpha}{sub ox}), and radio-to-X-ray ({alpha}{sub rx}) spectral indices are distributed in the intervals (0.17,0.59), (0.56,1.48), and (0.41,0.75), respectively. In the optical energy range, the overall flux variability increases, on average, towards shorter wavelengths: ({Delta}m) = 1.22, 1.50, and 1.82 mag through the R, V, B bands of Johnson-Cousins system, respectively. XBLs seem be optically less variable at the intranight timescales compared to the radio-selected BL Lacs (RBLs).« less
Mastin, M.C.; Kresch, D.L.
2005-01-01
The 1921 peak discharge at Skagit River near Concrete, Washington (U.S. Geological Survey streamflow-gaging station 12194000), was verified using peak-discharge data from the flood of October 21, 2003, the largest flood since 1921. This peak discharge is critical to determining other high discharges at the gaging station and to reliably estimating the 100-year flood, the primary design flood being used in a current flood study of the Skagit River basin. The four largest annual peak discharges of record (1897, 1909, 1917, and 1921) were used to determine the 100-year flood discharge at Skagit River near Concrete. The peak discharge on December 13, 1921, was determined by James E. Stewart of the U.S. Geological Survey using a slope-area measurement and a contracted-opening measurement. An extended stage-discharge rating curve based on the 1921 peak discharge was used to determine the peak discharges of the three other large floods. Any inaccuracy in the 1921 peak discharge also would affect the accuracies of the three other largest peak discharges. The peak discharge of the 1921 flood was recalculated using the cross sections and high-water marks surveyed after the 1921 flood in conjunction with a new estimate of the channel roughness coefficient (n value) based on an n-verification analysis of the peak discharge of the October 21, 2003, flood. The n value used by Stewart for his slope-area measurement of the 1921 flood was 0.033, and the corresponding calculated peak discharge was 240,000 cubic feet per second (ft3/s). Determination of a single definitive water-surface profile for use in the n-verification analysis was precluded because of considerable variation in elevations of surveyed high-water marks from the flood on October 21, 2003. Therefore, n values were determined for two separate water-surface profiles thought to bracket a plausible range of water-surface slopes defined by high-water marks. The n value determined using the flattest plausible slope was 0.024 and the corresponding recalculated discharge of the 1921 slope-area measurement was 266,000 ft3/s. The n value determined using the steepest plausible slope was 0.032 and the corresponding recalculated discharge of the 1921 slope-area measurement was 215,000 ft3/s. The two recalculated discharges were 10.8 percent greater than (flattest slope) and 10.4 percent less than (steepest slope) the 1921 peak discharge of 240,000 ft3/s. The 1921 peak discharge was not revised because the average of the two recalculated discharges (240,500 ft3/s) is only 0.2 percent greater than the 1921 peak discharge.
Robust Audio Watermarking Scheme Based on Deterministic Plus Stochastic Model
NASA Astrophysics Data System (ADS)
Dhar, Pranab Kumar; Kim, Cheol Hong; Kim, Jong-Myon
Digital watermarking has been widely used for protecting digital contents from unauthorized duplication. This paper proposes a new watermarking scheme based on spectral modeling synthesis (SMS) for copyright protection of digital contents. SMS defines a sound as a combination of deterministic events plus a stochastic component that makes it possible for a synthesized sound to attain all of the perceptual characteristics of the original sound. In our proposed scheme, watermarks are embedded into the highest prominent peak of the magnitude spectrum of each non-overlapping frame in peak trajectories. Simulation results indicate that the proposed watermarking scheme is highly robust against various kinds of attacks such as noise addition, cropping, re-sampling, re-quantization, and MP3 compression and achieves similarity values ranging from 17 to 22. In addition, our proposed scheme achieves signal-to-noise ratio (SNR) values ranging from 29 dB to 30 dB.
The Intensity Distribution for Gamma-Ray Bursts Observed with BATSE
NASA Technical Reports Server (NTRS)
Pendleton, Geoffrey N.; Mallozzi, Robert S.; Paciesas, William S.; Briggs, Michael S.; Preece, Robert D.; Koshut, Tom M.; Horack, John M.; Meegan, Charles A.; Fishman, Gerald J.; Hakkila, Jon;
1996-01-01
The intensity distributions of gamma-ray bursts observed by BATSE from 19 April 1991 to 19 September 1994 are presented. For this data set, (V/V(sub max)) is 0.329 +/- 0.011, which is 15.5 sigma away from the value of 0.5 expected for a homogeneous distribution. Standard cosmological model parameters are obtained by fitting the differentially binned peak flux distribution expressed in units of photons cm(exp -2) s(exp -1) in the energy range 50-300 keV. The value of z calculated for a peak flux of 1 photon cm(exp -2) s(exp -1) is 0.8 +/- 0.33. The procedures used to produce the peak flux data and C(sub p)/C(sub lim) data are presented. The differences between the two representations of burst intensity are emphasized so that researchers can determine which type of data is most appropriate for their studies. The sky sensitivity correction as a function of intensity for the peak flux data is also described.
Francart, Suzanne J; Hawes, Emily M; Deal, Allison M; Adcock, Dorothy M; Gosselin, Robert; Jeanneret, Cheryl; Friedman, Kenneth D; Moll, Stephan
2014-06-01
Knowledge of anticoagulation status during rivaroxaban therapy is desirable in certain clinical situations. It was the study objective to determine coagulation tests most useful for assessing rivaroxaban's anticoagulant effect. Peak and trough blood samples from 29 patients taking rivaroxaban 20 mg daily were collected. Mass spectrometry and various coagulation assays were performed. "On-therapy range" was defined as the rivaroxaban concentrations determined by LC-MS/MS. A "misprediction percentage" was calculated based on how often results of each coagulation assay were in the normal reference range, while the rivaroxaban concentration was in the "on-therapy" range. The on-therapy range was 8.9-660 ng/ml. The misprediction percentages for prothrombin time (PT) and activated partial thromboplastin time (aPTT), using multiple reagents and coagulometers, ranged from 10%-52% and 31%-59%, respectively. PT, aPTT and activated clotting time (ACT) were insensitive to trough rivaroxaban: 59%, 62%, and 80% of samples had a normal result, respectively. Over 95% of PT and ACT values were elevated at peak. Four different rivaroxaban calibrated anti-Xa assays had R² values >0.98, demonstrating strong correlations with rivaroxaban drug levels. In conclusion, PT, aPTT and ACT are often normal in patients on therapeutic doses of rivaroxaban. However, PT and ACT may have clinical utility at higher drug plasma levels. Rivaroxaban calibrated anti-factor Xa assays can accurately identify low and high on-therapy rivaroxaban drug levels and, therefore, have superior utility in all clinical situations where assessment of anticoagulation status may be beneficial.
Acute liver injury due to flavocoxid (Limbrel), a medical food for osteoarthritis: a case series.
Chalasani, Naga; Vuppalanchi, Raj; Navarro, Victor; Fontana, Robert; Bonkovsky, Herbert; Barnhart, Huiman; Kleiner, David E; Hoofnagle, Jay H
2012-06-19
Flavocoxid is a prescription medical food that is used to treat osteoarthritis. It is a proprietary blend of 2 flavonoids, baicalin and catechins, which are derived from the botanicals Scutellaria baicalensis and Acacia catechu, respectively. To describe characteristics of patients with acute liver injury suspected of being caused by flavocoxid. Case series. Drug-Induced Liver Injury Network Prospective Study ongoing at multiple academic medical centers since 2004. Four adults with liver injury. Clinical characteristics, liver biochemistry values, and outcomes. Among 877 patients enrolled in the prospective study, 4 had liver injury suspected to have been caused by flavocoxid. All were women; ages ranged from 57 to 68 years. All developed symptoms and signs of liver injury within 1 to 3 months after initiating flavocoxid. Liver injury was characterized by marked elevations in levels of alanine aminotransferase (mean peak, 1268 U/L; range, 741 to 1540 U/L), alkaline phosphatase (mean peak, 510 U/L; range, 286 to 770 U/L), and serum bilirubin (mean peak, 160.7 µmol/L [9.4 mg/dL]; range, 34.2 to 356 µmol/L [2.0 to 20.8 mg/dL]). Liver biochemistry values decreased to the normal range within 3 to 12 weeks after flavocoxid was stopped, and all patients recovered without experiencing acute liver failure or chronic liver injury. Causality was adjudicated as highly likely in 3 patients and as possible in 1 patient. The frequency and mechanism of liver injury could not be assessed. Flavocoxid can cause clinically significant liver injury, which seems to resolve within weeks after cessation.
Isothermal decay studies of intermediate energy levels in quartz.
Veronese, I; Giussani, A; Göksu, H Y; Martini, M
2004-05-01
The recent interest in the thermoluminescence of quartz extracted from unfired building materials, such as mortar and concrete for dose reconstruction applications, led to the requirement of an accurate determination of the lifetime of the intermediate glow peaks in this mineral. The prediction of the lifetimes of these peaks is helpful in establishing the likely time range within which retrospective measurements can be carried out. These peaks, corresponding to intermediate energy levels, occur in the glow curve in the temperature range 150-250 degrees C (heating rate 2 degrees C/s). Lifetimes of 720+/-70 days and 580+/-70 years (at a temperature of 15 degrees C) were derived for the two main peaks placed in the glow curve at approximately 150 degrees C and 200 degrees C, respectively, using the isothermal decay technique. These results as well as the estimated values of the trap parameters (thermal activation energy and frequency factor) have been compared with the data already available in the literature.
Preparation of TiN films by reactive high-power pulsed sputtering Penning discharges
NASA Astrophysics Data System (ADS)
Kimura, Takashi; Yoshida, Ryo; Mishima, Toshihiko; Azuma, Kingo; Nakao, Setsuo
2018-06-01
Titanium nitride (TiN) films are prepared by reactive high-power pulsed sputtering Penning discharges at a total pressure of 0.7 Pa and an average power of 60 W, where the nitrogen fraction is varied up to 15%. The peak value of the instantaneous power ranges between 3 and 14 kW, and the peak power density ranges between 0.3 and 1.2 kW cm‑2. The hardness of TiN films is higher than 22 GPa at the nitrogen fractions lower than 10% and it reaches 31 GPa at a nitrogen fraction of 5%. The X-ray diffraction peak of TiN(111) texture is observed for all prepared films, showing the grain size of about 10 nm. In X-ray photoelectron spectroscopy, oxygen is mainly bonded to titanium, but the intensity of the TiN bond is dominant in the entire Ti 2p spectrum. The intensity ratio of N 1s to Ti 2p ranges between 0.85 and 0.95.
NASA Astrophysics Data System (ADS)
Deng, Lin
2016-05-01
This paper examines the seismic effects experienced by a solar receiver mounted on concrete towers with different fundamental periods. Ten concrete towers are modeled with the empty solar receiver structure and loaded solar receiver structure to examine the tower seismic effects on the solar receiver. The fundamental periods of the towers range from 0.22 seconds to 4.58 seconds, with heights ranging from 40.5 meters to 200 meters. Thirty earthquake ground motion records are used to investigate the responses of each of the combined receiver-on-tower models as well as the receiver-on-ground models by the STAAD Pro software using time history analyses. The earthquake ground motion records are chosen based on the ratio of the peak ground acceleration to the peak ground velocity, ranging from 0.29 g/m/s to 4.88 g/m/s. For each of the combined models, the base shear at the interface between the receiver and the concrete tower is compared with the base shear of the receiver-on-ground model, and the ratio of the two base shears represents the structure amplification factor. It is found that the peak mean plus one standard deviation value of the structure amplification factor matches well with equation 13.3-1 in ASCE 7-10 for the empty solar receiver structure. However, when the solar receiver structure is loaded with dead loads, the peak value is greatly suppressed, and using equation 13.3-1 in ASCE 7-10 will be overly conservative.
NASA Astrophysics Data System (ADS)
Khan, Mohammad Khurram
The Monte-Carlo based simulation environment for radiation therapy (SERA) software is used to simulate the dose administered to a patient undergoing boron neutron capture therapy (BNCT). Point sampling of tumor tissue results in an estimate of a uniform boron concentration scaling factor of 3.5. Under conventional treatment protocols, this factor is used to scale the boron component of the dose linearly and homogenously within the tumor and target volumes. The average dose to the tumor cells by such a method could be improved by better methods of quantifying the in-vivo 10B biodistribution. A better method includes radiolabeling para-Boronophenylalanine (p-BPA) with 18F and imaging the pharmaceutical using positron emission tomography (PET). This biodistribution of 18F-BPA can then be used to better predict the average dose delivered to the tumor regions. This work uses registered 18F-BPA PET images to incorporate the in-vivo boron biodistribution within current treatment planning. The registered 18F-BPA PET images are then coupled in a new computer software, PET2MRI.m, to linearly scale the boron component of the dose. A qualititative and quantitative assessment of the dose contours is presented using the two approaches. Tumor volume, tumor axial extent, and target locations are compared between using MRI or PET images to define the tumor volume. In addition, peak-to-normal brain value at tumor axial center is determined for pre and post surgery patients using 18F-BPA PET images. The differences noted between the registered GBM tumor volumes (range: 34.04--136.36%), tumor axial extent (range: 20--150%), and the beam target location (1.27--4.29 cm) are significantly different. The peak-to-normal brain values are also determined at the tumor axial center using the 18F-BPA PET images. The peak-to-normal brain values using the last frame of the pre-surgery study for the GBM patients ranged from 2.05--3.4. For post surgery time weighted PET data, the peak-to-normal brain value in the residual parts of the tumor ranged from 1.5--1.7. Qualitatively, boron dose contours are greatly shifted using PET images when compared with MRI images. Collectively, these differences can lead to significant reorientation of the beam and can significantly impact current BNCT treatment planning.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Delice, S., E-mail: sdelice@metu.edu.tr; Isik, M.; Gasanly, N.M.
2015-10-15
Highlights: • Optical and thermoluminescence properties of Ga{sub 4}S{sub 3}Se crystals were investigated. • Indirect and direct band gap energies were found as 2.39 and 2.53 eV, respectively. • The activation energy of the trap center was determined as 495 meV. - Abstract: Optical and thermoluminescence properties on GaS{sub 0.75}Se{sub 0.25} crystals were investigated in the present work. Transmission and reflection measurements were performed at room temperature in the wavelength range of 400–1000 nm. Analysis revealed the presence of indirect and direct transitions with band gap energies of 2.39 and 2.53 eV, respectively. TL spectra obtained at low temperatures (10–300more » K) exhibited one peak having maximum temperature of 168 K. Observed peak was analyzed using curve fitting, initial rise and peak shape methods to calculate the activation energy of the associated trap center. All applied methods were consistent with the value of 495 meV. Attempt-to-escape-frequency and capture cross section of the trap center were determined using the results of curve fitting. Heating rate dependence studies of the glow curve in the range of 0.4–0.8 K/s resulted with decrease of TL intensity and shift of the peak maximum temperature to higher values.« less
Valentino, L A; Pipe, S W; Collins, P W; Blanchette, V S; Berntorp, E; Fischer, K; Ewenstein, B M; Oh, M; Spotts, G
2016-07-01
We previously showed that pharmacokinetic-guided prophylaxis (PKP) allows the dosing interval to be extended while maintaining a specific trough level. However, the associations of peak factor VIII (FVIII) levels and area under the curve (AUC) with breakthrough bleeding have not been investigated. The aim of this study was to analyse data from the PKP arm to determine whether peak FVIII levels, AUC and time with FVIII levels in a haemostatically effective range are independent predictors of bleeding during prophylaxis. Post hoc analysis of the association of FVIII levels and AUC with annualized bleeding rate in 34 patients on PKP. During 1 year of PKP, 131 bleeding episodes occurred in 24/34 patients. Average peak FVIII levels ranged from 24 to 168 IU dL(-1) , with higher values associated with a decreased risk for all bleeding (joint and non-joint; P < 0.01) and joint bleeding (P < 0.01). Following rFVIII infusion, median percent of time spent with FVIII levels >20 IU dL(-1) was 22%; median AUC was 1363. Both values were significantly associated with a lower ABR when targeting a 1% trough at 72 h. When PKP was administered every third day, higher peak FVIII levels, higher AUC and more time spent per week with FVIII levels >20 IU dL(-1) provided increased protection from joint and non-joint bleeding. These data highlight the potential impact of variability in individual pharmacokinetic and bleeding risk and support the need for high peak levels and AUC in some patients treated every third day. The findings do not necessarily apply to alternate-day or other prophylactic dosing regimens. © 2016 The Authors. Haemophilia Published by John Wiley & Sons Ltd.
Waltemeyer, Scott D.
2008-01-01
Estimates of the magnitude and frequency of peak discharges are necessary for the reliable design of bridges, culverts, and open-channel hydraulic analysis, and for flood-hazard mapping in New Mexico and surrounding areas. The U.S. Geological Survey, in cooperation with the New Mexico Department of Transportation, updated estimates of peak-discharge magnitude for gaging stations in the region and updated regional equations for estimation of peak discharge and frequency at ungaged sites. Equations were developed for estimating the magnitude of peak discharges for recurrence intervals of 2, 5, 10, 25, 50, 100, and 500 years at ungaged sites by use of data collected through 2004 for 293 gaging stations on unregulated streams that have 10 or more years of record. Peak discharges for selected recurrence intervals were determined at gaging stations by fitting observed data to a log-Pearson Type III distribution with adjustments for a low-discharge threshold and a zero skew coefficient. A low-discharge threshold was applied to frequency analysis of 140 of the 293 gaging stations. This application provides an improved fit of the log-Pearson Type III frequency distribution. Use of the low-discharge threshold generally eliminated the peak discharge by having a recurrence interval of less than 1.4 years in the probability-density function. Within each of the nine regions, logarithms of the maximum peak discharges for selected recurrence intervals were related to logarithms of basin and climatic characteristics by using stepwise ordinary least-squares regression techniques for exploratory data analysis. Generalized least-squares regression techniques, an improved regression procedure that accounts for time and spatial sampling errors, then were applied to the same data used in the ordinary least-squares regression analyses. The average standard error of prediction, which includes average sampling error and average standard error of regression, ranged from 38 to 93 percent (mean value is 62, and median value is 59) for the 100-year flood. The 1996 investigation standard error of prediction for the flood regions ranged from 41 to 96 percent (mean value is 67, and median value is 68) for the 100-year flood that was analyzed by using generalized least-squares regression analysis. Overall, the equations based on generalized least-squares regression techniques are more reliable than those in the 1996 report because of the increased length of record and improved geographic information system (GIS) method to determine basin and climatic characteristics. Flood-frequency estimates can be made for ungaged sites upstream or downstream from gaging stations by using a method that transfers flood-frequency data at the gaging station to the ungaged site by using a drainage-area ratio adjustment equation. The peak discharge for a given recurrence interval at the gaging station, drainage-area ratio, and the drainage-area exponent from the regional regression equation of the respective region is used to transfer the peak discharge for the recurrence interval to the ungaged site. Maximum observed peak discharge as related to drainage area was determined for New Mexico. Extreme events are commonly used in the design and appraisal of bridge crossings and other structures. Bridge-scour evaluations are commonly made by using the 500-year peak discharge for these appraisals. Peak-discharge data collected at 293 gaging stations and 367 miscellaneous sites were used to develop a maximum peak-discharge relation as an alternative method of estimating peak discharge of an extreme event such as a maximum probable flood.
Reddy, M V; Yu, Cai; Jiahuan, Fan; Loh, Kian Ping; Chowdari, B V R
2013-05-22
We report the synthesis of CuO material by molten salt method at a temperature range, 280 to 950 °C for 3 h in air. This report includes studies on the effect of morphology, crystal structure and electrochemical properties of CuO prepared at different temperatures. Obtained CuO was characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), and Brunauer-Emmett-Teller (BET) surface area methods. Samples prepared at ≥410 °C showed a single-phase material with a lattice parameter value of a = 4.69 Å, b = 3.43 Å, c = 5.13 Å and surface area values are in the range 1.0-17.0 m(2) g(-1). Electrochemical properties were evaluated via cyclic voltammetry (CV) and galvanostatic cycling studies. CV studies showed a minor difference in the peak potentials depending on preparation temperature and all compounds exhibit a main anodic peak at ~2.45 V and cathodic peaks at ~0.85 V and ~1.25 V vs Li. CuO prepared at 750 °C showed high and stable capacity of ~620 mA h g(-1) at the end of 40th cycle.
Synthetic calibration of a Rainfall-Runoff Model
Thompson, David B.; Westphal, Jerome A.; ,
1990-01-01
A method for synthetically calibrating storm-mode parameters for the U.S. Geological Survey's Precipitation-Runoff Modeling System is described. Synthetic calibration is accomplished by adjusting storm-mode parameters to minimize deviations between the pseudo-probability disributions represented by regional regression equations and actual frequency distributions fitted to model-generated peak discharge and runoff volume. Results of modeling storm hydrographs using synthetic and analytic storm-mode parameters are presented. Comparisons are made between model results from both parameter sets and between model results and observed hydrographs. Although mean storm runoff is reproducible to within about 26 percent of the observed mean storm runoff for five or six parameter sets, runoff from individual storms is subject to large disparities. Predicted storm runoff volume ranged from 2 percent to 217 percent of commensurate observed values. Furthermore, simulation of peak discharges was poor. Predicted peak discharges from individual storm events ranged from 2 percent to 229 percent of commensurate observed values. The model was incapable of satisfactorily executing storm-mode simulations for the study watersheds. This result is not considered a particular fault of the model, but instead is indicative of deficiencies in similar conceptual models.
Understanding Montane Snow Water Equivalent Response to Climate Change and Variability
NASA Astrophysics Data System (ADS)
Huning, L. S.; AghaKouchak, A.
2017-12-01
Large populations worldwide rely on the seasonal snowpack for the majority of their water resources. Warming temperatures and other hydrometeorological changes impact the timing, distribution, and amount of montane snow water equivalent (SWE). Therefore, developing an improved understanding of the historical response to changing atmospheric drivers across snow-dominated mountainous regions has significant societal value related to water resources management and environmental hazards (i.e. flooding and droughts) for a future warming climate. Utilizing multi-decadal snow data sets and a probabilistic risk model over mountain ranges such as the Sierra Nevada (USA), the response of snowpack characteristics (e.g. SWE/snowfall, peak SWE, day of peak SWE, melt rate, etc.) to unit changes in hydrometeorological quantities (e.g. air temperature, humidity, winds, etc.) is quantified. The likelihood that the amount of SWE will exceed specified amounts (e.g. long-term peak SWE value) is presented for a range of climatic conditions. This study compares hydrologic response of montane SWE across windward and leeward basins, elevational bands, and regions of differing physiographic characteristics to understand how projected global warming such as a unit increase in air temperature or changes in other hydrometeorological quantities impact SWE at different spatial scales (i.e. basin-wide and range-wide). It provides insight that can be used to understand vulnerabilities of the seasonal snowpack to changes in climatic and atmospheric conditions.
Gender differences associated with rearfoot, midfoot, and forefoot kinematics during running.
Takabayashi, Tomoya; Edama, Mutsuaki; Nakamura, Masatoshi; Nakamura, Emi; Inai, Takuma; Kubo, Masayoshi
2017-11-01
Females, as compared with males, have a higher proportion of injuries in the foot region. However, the reason for this gender difference regarding foot injuries remains unclear. This study aimed to investigate gender differences associated with rearfoot, midfoot, and forefoot kinematics during running. Twelve healthy males and 12 females ran on a treadmill. The running speed was set to speed which changes from walking to running. Three-dimensional kinematics of rearfoot, midfoot, and forefoot were collected and compared between males and females. Furthermore, spatiotemporal parameters (speed, cadence, and step length) were measured. In the rearfoot angle, females showed a significantly greater peak value of plantarflexion and range of motion in the sagittal plane as compared with males (effect size (ES) = 1.55 and ES = 1.12, respectively). In the midfoot angle, females showed a significantly greater peak value of dorsiflexion and range of motion in the sagittal plane as compared with males (ES = 1.49 and ES = 1.71, respectively). The forefoot peak angles and ranges of motion were not significantly different between the genders in all three planes. A previous study suggested that a gender-related difference in excessive motions of the lower extremities during running has been suggested as a contributing factor to running injuries. Therefore, the present investigation may provide insight into the reason for the high incidence of foot injuries in females.
Petri, Anette Lykke; Simonsen, Anja Hviid; Yip, Tai-Tung; Hogdall, Estrid; Fung, Eric T; Lundvall, Lene; Hogdall, Claus
2009-01-01
To examine whether urine can be used to measure specific ovarian cancer proteomic profiles and whether one peak alone or in combination with other peaks or CA125 has the sensitivity and specificity to discriminate between ovarian cancer pelvic mass and benign pelvic mass. A total of 209 women were admitted for surgery for pelvic mass at the Gynaecological Department at Rigshospitalet, Copenhagen. Of the women, 156 had benign gynaecological tumors, 13 had borderline tumors and 40 had malignant epithelial ovarian cancer. The prospectively and preoperatively collected urine samples were aliquotted and frozen at -80 degrees until the time of analysis. The urine was fractionated using equalizer bead technology and then analyzed with surface-enhanced laser desorption/ionization time-of-flight mass spectrometry. Biomarkers were purified and identified using combinations of chromatographic techniques and tandem mass spectrometry. Benign and malignant ovarian cancer cases were compared; 21 significantly different peaks (p<0.001) were visualized using Mann-Whitney analysis, ranging in m/z values from 1,500 to 185,000. The three most significant peaks were purified and identified as fibrinogen alpha fragment (m/z=2570.21), collagen alpha 1 (III) fragment (m/z=2707.32) and fibrinogen beta NT fragment (m/z=4425.09). The area under the receiver operator characteristic curve (ROC AUC) value for these three peaks in combination was 0.88, and their ROC AUC value in combination with CA125 was 0.96. This result supports the feasibility of using urine as a clinical diagnostic medium, and the ROC AUC value for the three most significant peaks in combination with or without CA125 demonstrates the enhanced prediction performance of combined marker analysis.
Zhao, Jun; Zhang, Yu; Wu, Kangbing; Chen, Jianwei; Zhou, Yikai
2011-09-15
A novel electrochemical method using multi-wall carbon nanotube (MWNT) film-modified electrode was developed for the detection of quinoline yellow. In pH 8 phosphate buffer, an irreversible oxidation peak at 0.71V was observed for quinoline yellow. Compared with the unmodified electrode, the MWNT film-modified electrode greatly increases the oxidation peak current of quinoline yellow, showing notable enhancement effect. The effects of pH value, amount of MWNT, accumulation potential and time were studied on the oxidation peak current of quinoline yellow. The linear range is from 0.75 to 20mgL(-1), and the limit of detection is 0.5mgL(-1). It was applied to the detection of quinoline yellow in commercial soft drinks, and the results consisted with the value that obtained by high-performance liquid chromatography. Copyright © 2011 Elsevier Ltd. All rights reserved.
Doppler aortic flow velocity measurement in healthy children.
Sohn, S.; Kim, H. S.
2001-01-01
To determine normal values for Doppler parameters of left ventricular function, ascending aortic blood flow velocity was measured by pulsed wave Doppler echocardiography in 63 healthy children with body surface area (BSA) < 1 m(2) (age < 10 yr). Peak velocity was independent of sex, but increased with body size. Mean acceleration was related to peak velocity (r = 0.75, p < 0.0001). Both stroke distance and ejection time had strong negative correlations with heart rate and positive correlations with BSA, suggesting that these parameters should be evaluated in relation to heart rate and body size. Mean intra- and interobserver variability for peak velocity, ejection time, stroke and minute distance ranged from 3 to 7%, whereas variability for acceleration time was 9 to 13%. These data may be used as reference values for the assessment of hemodynamic states in young children with cardiac disease. PMID:11306737
Nie, Bingbing; Forman, Jason L; Joodaki, Hamed; Wu, Taotao; Kent, Richard W
2016-09-01
Occupants with extreme body size and shape, such as the small female or the obese, were reported to sustain high risk of injury in motor vehicle crashes (MVCs). Dimensional scaling approaches are widely used in injury biomechanics research based on the assumption of geometrical similarity. However, its application scope has not been quantified ever since. The objective of this study is to demonstrate the valid range of scaling approaches in predicting the impact response of the occupants with focus on the vulnerable populations. The present analysis was based on a data set consisting of 60 previously reported frontal crash tests in the same sled buck representing a typical mid-size passenger car. The tests included two categories of human surrogates: 9 postmortem human surrogates (PMHS) of different anthropometries (stature range: 147-189 cm; weight range: 27-151 kg) and 5 anthropomorphic test devices (ATDs). The impact response was considered including the restraint loads and the kinematics of multiple body segments. For each category of the human surrogates, a mid-size occupant was selected as a baseline and the impact response was scaled specifically to another subject based on either the body mass (body shape) or stature (the overall body size). To identify the valid range of the scaling approach, the scaled response was compared to the experimental results using assessment scores on the peak value, peak timing (the time when the peak value occurred), and the overall curve shape ranging from 0 (extremely poor) to 1 (perfect match). Scores of 0.7 to 0.8 and 0.8 to 1.0 indicate fair and acceptable prediction. For both ATDs and PMHS, the scaling factor derived from body mass proved an overall good predictor of the peak timing for the shoulder belt (0.868, 0.829) and the lap belt (0.858, 0.774) and for the peak value of the lap belt force (0.796, 0.869). Scaled kinematics based on body stature provided fair or acceptable prediction on the overall head/shoulder kinematics (0.741, 0.822 for the head; 0.817, 0.728 for the shoulder) regardless of the anthropometry. The scaling approach exhibited poor prediction capability on the curve shape for the restraint force (0.494 and 0.546 for the shoulder belt; 0.585 and 0.530 for the lap belt). It also cannot well predict the excursion of the pelvis and the knee. The results revealed that for the peak lap belt force and the forward motion of the head and shoulder, the underlying linear relationship with body size and shape is valid over a wide anthropometric range. The chaotic nature of the dynamic response cannot be fully recovered by the assumption of the whole-body geometrical similarity, especially for the curve shape. The valid range of the scaling approach established in this study can be reasonably referenced in predicting the impact response of a given specific population with expected deviation. Application of this knowledge also includes proposing strategies for restraint configuration and providing reference for ATD and/or human body model (HBM) development for vulnerable occupants.
Activities of NASA's Global Modeling Initiative (GMI) in the Assessment of Subsonic Aircraft Impact
NASA Technical Reports Server (NTRS)
Rodriquez, J. M.; Logan, J. A.; Rotman, D. A.; Bergmann, D. J.; Baughcum, S. L.; Friedl, R. R.; Anderson, D. E.
2004-01-01
The Intergovernmental Panel on Climate Change estimated a peak increase in ozone ranging from 7-12 ppbv (zonal and annual average, and relative to a baseline with no aircraft), due to the subsonic aircraft in the year 2015, corresponding to aircraft emissions of 1.3 TgN/year. This range of values presumably reflects differences in model input (e.g., chemical mechanism, ground emission fluxes, and meteorological fields), and algorithms. The model implemented by the Global Modeling Initiative allows testing the impact of individual model components on the assessment calculations. We present results of the impact of doubling the 1995 aircraft emissions of NOx, corresponding to an extra 0.56 TgN/year, utilizing meteorological data from NASA's Data Assimilation Office (DAO), the Goddard Institute for Space Studies (GISS), and the Middle Atmosphere Community Climate Model, version 3 (MACCM3). Comparison of results to observations can be used to assess the model performance. Peak ozone perturbations ranging from 1.7 to 2.2 ppbv of ozone are calculated using the different fields. These correspond to increases in total tropospheric ozone ranging from 3.3 to 4.1 Tg/Os. These perturbations are consistent with the IPCC results, due to the difference in aircraft emissions. However, the range of values calculated is much smaller than in IPCC.
Pulsed focused ultrasound-induced displacements in confined in vitro blood clots.
Wright, Cameron C; Hynynen, Kullervo; Goertz, David E
2012-03-01
Ultrasound has been shown to potentiate the effects of tissue plasminogen activator to improve clot lysis in a range of in vitro and in vivo studies as well as in clinical trials. One possible mechanism of action is acoustic radiation force-induced clot displacements. In this study, we investigate the temporal and spatial dynamics of clot displacements and strain initiated by focused ultrasound pulses. Displacements were produced by a 1.51 MHz f-number 1 transducer over a range of acoustic powers (1-85 W) in clots constrained within an agar vessel phantom channel. Displacements were tracked during and after a 5.45 ms therapy pulse using a 20 MHz high-frequency ultrasound imaging probe. Peak thrombus displacements were found to be linear as a function of acoustic power up to 60 W before leveling off near 128 μm for the highest transmit powers. The time to peak displacement and recovery time of blood clots was largely independent of acoustic powers with measured values near 2 ms. A linear relationship between peak axial strain and transmit power was observed, reaching a peak value of 11% at 35 W. The peak strain occurred ~0.75 mm from the focal zone for all powers investigated in both lateral and axial directions. These results indicate that substantial displacements can be induced by focused ultrasound in confined blood clots, and that the spatial and temporal displacement patterns are complex and highly dependent on exposure conditions, which has implications for future work investigating their link to clot lysis and for developing approaches to exploit these effects.
Boore, David; Campbell, Kenneth W.
2017-01-01
Adjustment factors are provided for converting ground‐motion intensity measures between central and eastern North America (CENA) sites with different reference‐rock site conditions (VS30=760, 2000, and 3000 m/s) for moment magnitudes ranging from 2 to 8, rupture distances ranging from 2 to 1200 km, Fourier amplitude spectra (FAS) for frequencies ranging from 0.01 to 100 Hz, response spectra for periods ranging from 0.01 to 10.0 s, peak ground acceleration, and peak ground velocity. The adjustment factors are given for a wide range of the site diminution parameters (κ0) for sites with VS30=760 m/s and for a κ0 of 0.006 s for two harder rock sites. Fourteen CENA velocity profiles with VS30 values within a factor of 1.1 of 760 m/s were used to derive average FAS amplification factors as a function of frequency, which were then used in simulations of peak ground‐motion parameters and response spectra to derive the adjustment factors. The amplification function differs from that used in western North America (e.g., Campbell and Boore, 2016) in having a peak near 9 Hz, due to the resonance of motions in the relatively thin low‐velocity material over hard rock that characterizes many CENA sites with VS30 near 760 m/s. We call these B/C sites, because this velocity marks the boundary between National Earthquake Hazards Reduction Program site classes B and C (Building Seismic Safety Council, 2004). The adjustments for short‐period motions are sensitive to the value of κ0, but there are very few if any determinations of κ0 for CENA B/C sites. For this reason, we determined κ0 from multiple recordings at Pinyon Flat Observatory (PFO), California, which has a velocity‐depth profile similar to those of CENA B/C sites. The PFO and other results from the literature suggest that appropriate values of κ0 for CENA B/C sites are expected to lie between 0.01 and 0.03 s.
Boore, David; Campbell, Kenneth W.
2017-01-01
Adjustment factors are provided for converting ground‐motion intensity measures between central and eastern North America (CENA) sites with different reference‐rock site conditions (VS30=760, 2000, and 3000 m/s) for moment magnitudes ranging from 2 to 8, rupture distances ranging from 2 to 1200 km, Fourier amplitude spectra (FAS) for frequencies ranging from 0.01 to 100 Hz, response spectra for periods ranging from 0.01 to 10.0 s, peak ground acceleration, and peak ground velocity. The adjustment factors are given for a wide range of the site diminution parameters (κ0) for sites with VS30=760 m/s and for a κ0 of 0.006 s for two harder rock sites. Fourteen CENA velocity profiles with VS30 values within a factor of 1.1 of 760 m/s were used to derive average FAS amplification factors as a function of frequency, which were then used in simulations of peak ground‐motion parameters and response spectra to derive the adjustment factors. The amplification function differs from that used in western North America (e.g., Campbell and Boore, 2016) in having a peak near 9 Hz, due to the resonance of motions in the relatively thin low‐velocity material over hard rock that characterizes many CENA sites with VS30 near 760 m/s. We call these B/C sites, because this velocity marks the boundary between National Earthquake Hazards Reduction Program site classes B and C (Building Seismic Safety Council, 2004). The adjustments for short‐period motions are sensitive to the value of κ0, but there are very few if any determinations of κ0 for CENA B/C sites. For this reason, we determined κ0from multiple recordings at Pinyon Flat Observatory (PFO), California, which has a velocity‐depth profile similar to those of CENA B/C sites. The PFO and other results from the literature suggest that appropriate values of κ0 for CENA B/C sites are expected to lie between 0.01 and 0.03 s.
Moody, J.A.; Martin, D.A.
2001-01-01
Wildfire alters the hydrologic response of watersheds, including the peak discharges resulting from subsequent rainfall. Improving predictions of the magnitude of flooding that follows wildfire is needed because of the increase in human population at risk in the wildland-urban interface. Because this wildland-urban interface is typically in mountainous terrain, we investigated rainfall-runoff relations by measuring the maximum 30 min rainfall intensity and the unit-area peak discharge (peak discharge divided by the area burned) in three mountainous watersheds (17-26.8 km2) after a wildfire. We found rainfall-runoff relations that relate the unit-area peak discharges to the maximum 30 min rainfall intensities by a power law. These rainfall-runoff relations appear to have a threshold value for the maximum 30 min rainfall intensity (around 10 mm h-1) such that, above this threshold, the magnitude of the flood peaks increases more rapidly with increases in intensity. This rainfall intensity could be used to set threshold limits in rain gauges that are part of an early-warning flood system after wildfire. The maximum unit-area peak discharges from these three burned watersheds ranged from 3.2 to 50 m3 s-1 km-2. These values could provide initial estimates of the upper limits of runoff that can be used to predict floods after wildfires in mountainous terrain. Published in 2001 by John Wiley and Sons, Ltd.
Ince, C; Ypey, DL; Van Furth, R; Verveen, AA
1983-01-01
Analysis of membrane potential recordings upon microelectrode impalement of four types of macrophages (cell lines P388D1 and PU5-1.8, cultured mouse peritoneal macrophages, and cultured human monocytes) reveals that these cells have membrane potentials at least two times more negative than sustained potential values (E(s)) frequently reported. Upon microelectrode entry into the cell (P388D1), the recorded potential drops to a peak value (E(p)) (mean -37 mV for 50 cells, range -15 to -70 mV) within 2 ms, after which it decays to a depolarized potential (E(n)) (mean -12 mV) in about 20 ms. Thereafter, the membrane develops one or a series of slow hyperpolarizations before a final sustained membrane potential (E(s)) (mean -14 mV, range -5 to -40) is established. The mean value of the peak of the first hyperpolarization (E(h)) is -30 mV (range -10 to -55 mV). The initial fast peak transient, measured upon microelectrode entry, was first described and analyzed by Lassen et al. (Lassen, U.V., A.M. T. Nielson, L. Pape, and L. O. Simonsen, 1971, J. Membr. Biol. 6:269-288 for other change in the membrane potential from its real value before impalement to a sustained depolarized value. This was shown to be true for macrophages by two-electrode impalements of single cells. Values of E(p), E(n), E(h), E(s), and membrane resistance (R(m)) measured for the other macrophages were similar to those of P388D1. From these results we conclude that E(p) is a better estimate of the true membrane potential of macrophages than E(s), and that the slow hyperpolarizations upon impalement should be regarded as transient repolarizations back to the original membrane potentials. Thus, analysis of the initial fast impalement transient can be a valuable aid in the estimation of the membrane potential of various sorts of small isolated cells by microelectrodes. PMID:6833384
Parameters of triggered-lightning flashes in Florida and Alabama
NASA Astrophysics Data System (ADS)
Fisher, R. J.; Schnetzer, G. H.; Thottappillil, R.; Rakov, V. A.; Uman, M. A.; Goldberg, J. D.
1993-12-01
Channel base currents from triggered lightning were measured at the NASA Kennedy Space Center, Florida, during summer 1990 and at Fort McClellan, Alabama, during summer 1991. Additionally, 16-mm cinematic records with 3- or 5-ms resolution were obtained for all flashes, and streak camera records were obtained for three of the Florida flashes. The 17 flashes analyzed here contained 69 strokes, all lowering negative charge from cloud to ground. Statistics on interstroke interval, no-current interstroke interval, total stroke duration, total stroke charge, total stroke action integral (∫ i2dt), return stroke current wave front characteristics, time to half peak value, and return stroke peak current are presented. Return stroke current pulses, characterized by rise times of the order of a few microseconds or less and peak values in the range of 4 to 38 kA, were found not to occur until after any preceding current at the bottom of the lightning channel fell below the noise level of less than 2 A. Current pulses associated with M components, characterized by slower rise times (typically tens to hundreds of microseconds) and peak values generally smaller than those of the return stroke pulses, occurred during established channel current flow of some tens to some hundreds of amperes. A relatively strong positive correlation was found between return stroke current average rate of rise and current peak. There was essentially no correlation between return stroke current peak and 10-90% rise time or between return stroke peak and the width of the current waveform at half of its peak value. Parameters of the lightning flashes triggered in Florida and Alabama are similar to each other but are different from those of triggered lightning recorded in New Mexico during the 1981 Thunderstorm Research International Program. Continuing currents that follow return stroke current peaks and last for more than 10 ms exhibit a variety of wave shapes that we have subdivided into four categories. All such continuing currents appear to start with a current pulse presumably associated with an M component. A brief summary of lightning parameters important for lightning protection, in a form convenient for practical use, is presented in an appendix.
Unit Hydrograph Peaking Analysis for Goose Creek Watershed in Virginia: A Case Study
2017-05-01
increment would not exceed 1.5 times the designed unit peak. The purpose of this study is to analyze the validity of this UHPF range of the Goose...confidence interval precipitation depths to the watershed in addition to the 50% value. This study concluded that a design event with a return period greater...In this study , the physically based GSSHA model was deployed to obtain corresponding design discharge from probable rainfall events. 3.2.1 GSSHA
Acute effects of static stretching on peak and end-range hamstring-to-quadriceps functional ratios.
Sekir, Ufuk; Arabaci, Ramiz; Akova, Bedrettin
2015-10-18
To evaluate if static stretching influences peak and end-range functional hamstring-to-quadriceps (H/Q) strength ratios in elite women athletes. Eleven healthy female athletes in an elite competitive level participated to the study. All the participants fulfilled the static stretching or non-stretching (control) intervention protocol in a randomized design on different days. Two static unassisted stretching exercises, one in standing and one in sitting position, were used to stretch both the hamstring and quadriceps muscles during these protocols. The total time for the static stretching was 6 ± 1 min. The isokinetic peak torque measurements for the hamstring and quadriceps muscles in eccentric and concentric modes and the calculations for the functional H/Q strength ratios at angular velocities of 60°/s and 180°/s were made before (pre) and after (post) the control or stretching intervention. The strength measurements and functional strength ratio calculations were based during the entire- and end-range of knee extension. The pre-test scores for quadriceps and hamstring peak torque and end range values were not significantly different between the groups (P > 0.05). Subsequently, although the control group did not exhibit significant changes in quadriceps and hamstring muscle strength (P > 0.05), static stretching decreased eccentric and concentric quadriceps muscle strength at both the 60°/s and 180°/s test speeds (P < 0.01). Similarly, static stretching also decreased eccentric and concentric hamstring muscle strength at both the 60°/s and 180°/s test speeds (P < 0.01). On the other hand, when the functional H/Q strength ratios were taken into consideration, the pre-intervention values were not significant different between the groups both during the entire and end range of knee extension (P > 0.05). Furthermore, the functional H/Q strength ratios exhibited no significant alterations during the entire and end ranges of knee extension both in the static stretching or the control intervention (P > 0.05). According to our results, static stretching routine does not influence functional H/Q ratio. Athletes can confidently perform static stretching during their warm-up routines.
Acute effects of static stretching on peak and end-range hamstring-to-quadriceps functional ratios
Sekir, Ufuk; Arabaci, Ramiz; Akova, Bedrettin
2015-01-01
AIM: To evaluate if static stretching influences peak and end-range functional hamstring-to-quadriceps (H/Q) strength ratios in elite women athletes. METHODS: Eleven healthy female athletes in an elite competitive level participated to the study. All the participants fulfilled the static stretching or non-stretching (control) intervention protocol in a randomized design on different days. Two static unassisted stretching exercises, one in standing and one in sitting position, were used to stretch both the hamstring and quadriceps muscles during these protocols. The total time for the static stretching was 6 ± 1 min. The isokinetic peak torque measurements for the hamstring and quadriceps muscles in eccentric and concentric modes and the calculations for the functional H/Q strength ratios at angular velocities of 60°/s and 180°/s were made before (pre) and after (post) the control or stretching intervention. The strength measurements and functional strength ratio calculations were based during the entire- and end-range of knee extension. RESULTS: The pre-test scores for quadriceps and hamstring peak torque and end range values were not significantly different between the groups (P > 0.05). Subsequently, although the control group did not exhibit significant changes in quadriceps and hamstring muscle strength (P > 0.05), static stretching decreased eccentric and concentric quadriceps muscle strength at both the 60°/s and 180°/s test speeds (P < 0.01). Similarly, static stretching also decreased eccentric and concentric hamstring muscle strength at both the 60°/s and 180°/s test speeds (P < 0.01). On the other hand, when the functional H/Q strength ratios were taken into consideration, the pre-intervention values were not significant different between the groups both during the entire and end range of knee extension (P > 0.05). Furthermore, the functional H/Q strength ratios exhibited no significant alterations during the entire and end ranges of knee extension both in the static stretching or the control intervention (P > 0.05). CONCLUSION: According to our results, static stretching routine does not influence functional H/Q ratio. Athletes can confidently perform static stretching during their warm-up routines. PMID:26495249
Optical absorption of zigzag single walled boron nitride nanotubes
NASA Astrophysics Data System (ADS)
Moradian, Rostam; Chegel, Raad; Behzad, Somayeh
2010-11-01
In a realistic three-dimensional model, optical matrix element and linear optical absorption of zigzag single walled boron nitride nanotubes (BNNTs) in the tight binding approximation are studied. In terms of absolute value of dipole matrix elements of the first three direct transitions at kz=0, we divided the zigzag BNNTs into three groups and investigated their optical absorption spectrum in energy ranges E<5, 7
Perez, Richard
2003-04-01
A load controller and method are provided for maximizing effective capacity of a non-controllable, renewable power supply coupled to a variable electrical load also coupled to a conventional power grid. Effective capacity is enhanced by monitoring power output of the renewable supply and loading, and comparing the loading against the power output and a load adjustment threshold determined from an expected peak loading. A value for a load adjustment parameter is calculated by subtracting the renewable supply output and the load adjustment parameter from the current load. This value is then employed to control the variable load in an amount proportional to the value of the load control parameter when the parameter is within a predefined range. By so controlling the load, the effective capacity of the non-controllable, renewable power supply is increased without any attempt at operational feedback control of the renewable supply. The expected peak loading of the variable load can be dynamically determined within a defined time interval with reference to variations in the variable load.
Large magnetocaloric effect of NdGa compound due to successive magnetic transitions
NASA Astrophysics Data System (ADS)
Zheng, X. Q.; Xu, J. W.; Shao, S. H.; Zhang, H.; Zhang, J. Y.; Wang, S. G.; Xu, Z. Y.; Wang, L. C.; Chen, J.; Shen, B. G.
2018-05-01
The magnetic behavior and MCE property of NdGa compound were studied in detail. According to the temperature dependence of magnetization (M-T) curve at 0.01 T, two sharp changes were observed at 20 K (TSR) and 42 K (TC), respectively, corresponding to spin reorientation and FM-PM transition. Isothermal magnetization curves up to 5 T at different temperatures were measured and magnetic entropy change (ΔSM) was calculated based on M-H data. Temperature dependences of -ΔSM for a field change of 0-2 T and 0-5 T show that there are two peaks on the curves corresponding to TSR and TC, respectively. The value of the two peaks is 6.4 J/kg K and 15.5 J/kg K for the field change of 0-5 T. Since the two peaks are close, the value of -ΔSM in the temperature range between TSR and TC keeps a large value. The excellent MCE performance of NdGa compound benefits from the existence of two successive magnetic transitions.
Flood frequency analysis for nonstationary annual peak records in an urban drainage basin
Villarini, G.; Smith, J.A.; Serinaldi, F.; Bales, J.; Bates, P.D.; Krajewski, W.F.
2009-01-01
Flood frequency analysis in urban watersheds is complicated by nonstationarities of annual peak records associated with land use change and evolving urban stormwater infrastructure. In this study, a framework for flood frequency analysis is developed based on the Generalized Additive Models for Location, Scale and Shape parameters (GAMLSS), a tool for modeling time series under nonstationary conditions. GAMLSS is applied to annual maximum peak discharge records for Little Sugar Creek, a highly urbanized watershed which drains the urban core of Charlotte, North Carolina. It is shown that GAMLSS is able to describe the variability in the mean and variance of the annual maximum peak discharge by modeling the parameters of the selected parametric distribution as a smooth function of time via cubic splines. Flood frequency analyses for Little Sugar Creek (at a drainage area of 110 km2) show that the maximum flow with a 0.01-annual probability (corresponding to 100-year flood peak under stationary conditions) over the 83-year record has ranged from a minimum unit discharge of 2.1 m3 s- 1 km- 2 to a maximum of 5.1 m3 s- 1 km- 2. An alternative characterization can be made by examining the estimated return interval of the peak discharge that would have an annual exceedance probability of 0.01 under the assumption of stationarity (3.2 m3 s- 1 km- 2). Under nonstationary conditions, alternative definitions of return period should be adapted. Under the GAMLSS model, the return interval of an annual peak discharge of 3.2 m3 s- 1 km- 2 ranges from a maximum value of more than 5000 years in 1957 to a minimum value of almost 8 years for the present time (2007). The GAMLSS framework is also used to examine the links between population trends and flood frequency, as well as trends in annual maximum rainfall. These analyses are used to examine evolving flood frequency over future decades. ?? 2009 Elsevier Ltd.
A Diffraction Method of Study of Thermal Quasiorder in a Finite Two-Dimensional Harmonic Lattice
NASA Astrophysics Data System (ADS)
Aranda, P.; Croset, B.
1995-09-01
Due to the non-existence of long-range order, the diffraction peaks of 2D-solids are considered to have a power-law shape g_p^{η-2}. Taking into account the finite size effects and calculating the powder average, we show that this power-law behaviour appears only for high q_p and then for very small intensities. It is therefore quite difficult and hazardous to characterise the quasiorder by using this asymptotic behaviour. Although the shape of the central part of the peak cannot be used to characterise the quasiorder, we show that, for a fairly good resolution, it is possible to determine η using this central part. This determination can be done irrespectively with the other details of the system by comparing the peak width to its value at low temperature, i.e., at low value of η. By using two diffraction peaks, we propose the simple relation: η(Q_{B_1})/Q_{B_1}^2=η(Q_{B_2})/Q_{B_2}^2 as a check of the two-dimensional quasiorder.
Impact of Wildfire Emissions on Chloride and Bromide Depletion in Marine Aerosol Particles.
Braun, Rachel A; Dadashazar, Hossein; MacDonald, Alexander B; Aldhaif, Abdulamonam M; Maudlin, Lindsay C; Crosbie, Ewan; Aghdam, Mojtaba Azadi; Hossein Mardi, Ali; Sorooshian, Armin
2017-08-15
This work examines particulate chloride (Cl - ) and bromide (Br - ) depletion in marine aerosol particles influenced by wildfires at a coastal California site in the summers of 2013 and 2016. Chloride exhibited a dominant coarse mode due to sea salt influence, with substantially diminished concentrations during fire periods as compared to nonfire periods. Bromide exhibited a peak in the submicrometer range during fire and nonfire periods, with an additional supermicrometer peak in the latter periods. Chloride and Br - depletions were enhanced during fire periods as compared to nonfire periods. The highest observed %Cl - depletion occurred in the submicrometer range, with maximum values of 98.9% (0.32-0.56 μm) and 85.6% (0.56-1 μm) during fire and nonfire periods, respectively. The highest %Br - depletion occurred in the supermicrometer range during fire and nonfire periods with peak depletion between 1.8-3.2 μm (78.8% and 58.6%, respectively). When accounting for the neutralization of sulfate by ammonium, organic acid particles showed the greatest influence on Cl - depletion in the submicrometer range. These results have implications for aerosol hygroscopicity and radiative forcing in areas with wildfire influence owing to depletion effects on composition.
The statistical overlap theory of chromatography using power law (fractal) statistics.
Schure, Mark R; Davis, Joe M
2011-12-30
The chromatographic dimensionality was recently proposed as a measure of retention time spacing based on a power law (fractal) distribution. Using this model, a statistical overlap theory (SOT) for chromatographic peaks is developed that estimates the number of peak maxima as a function of the chromatographic dimension, saturation and scale. Power law models exhibit a threshold region whereby below a critical saturation value no loss of peak maxima due to peak fusion occurs as saturation increases. At moderate saturation, behavior is similar to the random (Poisson) peak model. At still higher saturation, the power law model shows loss of peaks nearly independent of the scale and dimension of the model. The physicochemical meaning of the power law scale parameter is discussed and shown to be equal to the Boltzmann-weighted free energy of transfer over the scale limits. The scale is discussed. Small scale range (small β) is shown to generate more uniform chromatograms. Large scale range chromatograms (large β) are shown to give occasional large excursions of retention times; this is a property of power laws where "wild" behavior is noted to occasionally occur. Both cases are shown to be useful depending on the chromatographic saturation. A scale-invariant model of the SOT shows very simple relationships between the fraction of peak maxima and the saturation, peak width and number of theoretical plates. These equations provide much insight into separations which follow power law statistics. Copyright © 2011 Elsevier B.V. All rights reserved.
Oki, Delwyn S.; Rosa, Sarah N.; Yeung, Chiu W.
2010-01-01
This study provides an updated analysis of the magnitude and frequency of peak stream discharges in Hawai`i. Annual peak-discharge data collected by the U.S. Geological Survey during and before water year 2008 (ending September 30, 2008) at stream-gaging stations were analyzed. The existing generalized-skew value for the State of Hawai`i was retained, although three methods were used to evaluate whether an update was needed. Regional regression equations were developed for peak discharges with 2-, 5-, 10-, 25-, 50-, 100-, and 500-year recurrence intervals for unregulated streams (those for which peak discharges are not affected to a large extent by upstream reservoirs, dams, diversions, or other structures) in areas with less than 20 percent combined medium- and high-intensity development on Kaua`i, O`ahu, Moloka`i, Maui, and Hawai`i. The generalized-least-squares (GLS) regression equations relate peak stream discharge to quantified basin characteristics (for example, drainage-basin area and mean annual rainfall) that were determined using geographic information system (GIS) methods. Each of the islands of Kaua`i,O`ahu, Moloka`i, Maui, and Hawai`i was divided into two regions, generally corresponding to a wet region and a dry region. Unique peak-discharge regression equations were developed for each region. The regression equations developed for this study have standard errors of prediction ranging from 16 to 620 percent. Standard errors of prediction are greatest for regression equations developed for leeward Moloka`i and southern Hawai`i. In general, estimated 100-year peak discharges from this study are lower than those from previous studies, which may reflect the longer periods of record used in this study. Each regression equation is valid within the range of values of the explanatory variables used to develop the equation. The regression equations were developed using peak-discharge data from streams that are mainly unregulated, and they should not be used to estimate peak discharges in regulated streams. Use of a regression equation beyond its limits will produce peak-discharge estimates with unknown error and should therefore be avoided. Improved estimates of the magnitude and frequency of peak discharges in Hawai`i will require continued operation of existing stream-gaging stations and operation of additional gaging stations for areas such as Moloka`i and Hawai`i, where limited stream-gaging data are available.
Comparison of five portable peak flow meters.
Takara, Glaucia Nency; Ruas, Gualberto; Pessoa, Bruna Varanda; Jamami, Luciana Kawakami; Di Lorenzo, Valéria Amorim Pires; Jamami, Mauricio
2010-05-01
To compare the measurements of spirometric peak expiratory flow (PEF) from five different PEF meters and to determine if their values are in agreement. Inaccurate equipment may result in incorrect diagnoses of asthma and inappropriate treatments. Sixty-eight healthy, sedentary and insufficiently active subjects, aged from 19 to 40 years, performed PEF measurements using Air Zone, Assess, Galemed, Personal Best and Vitalograph peak flow meters. The highest value recorded for each subject for each device was compared to the corresponding spirometric values using Friedman's test with Dunn's post-hoc (p<0.05), Spearman's correlation test and Bland-Altman's agreement test. The median and interquartile ranges for the spirometric values and the Air Zone, Assess, Galemed, Personal Best and Vitalograph meters were 428 (263-688 L/min), 450 (350-800 L/min), 420 (310-720 L/min), 380 (300-735 L/min), 400 (310-685 L/min) and 415 (335-610 L/min), respectively. Significant differences were found when the spirometric values were compared to those recorded by the Air Zone(R) (p<0.001) and Galemed (p<0.01) meters. There was no agreement between the spirometric values and the five PEF meters. The results suggest that the values recorded from Galemed meters may underestimate the actual value, which could lead to unnecessary interventions, and that Air Zone meters overestimate spirometric values, which could obfuscate the need for intervention. These findings must be taken into account when interpreting both devices' results in younger people. These differences should also be considered when directly comparing values from different types of PEF meters.
Waythomas, C.F.; Walder, J.S.; McGimsey, R.G.; Neal, C.A.
1996-01-01
Aniakchak caldera, located on the Alaska Peninsula of southwest Alaska, formerly contained a large lake (estimated volume 3.7 ?? 109 m3) that rapidly drained as a result of failure of the caldera rim sometime after ca. 3400 yr B.P. The peak discharge of the resulting flood was estimated using three methods: (1) flow-competence equations, (2) step-backwater modeling, and (3) a dam-break model. The results of the dam-break model indicate that the peak discharge at the breach in the caldera rim was at least 7.7 ?? 104 m3 s-1, and the maximum possible discharge was ???1.1 ?? 106 m3 s-1. Flow-competence estimates of discharge, based on the largest boulders transported by the flood, indicate that the peak discharge values, which were a few kilometers downstream of the breach, ranged from 6.4 ?? 105 to 4.8 ?? 106 m3 s-1. Similar but less variable results were obtained by step-backwater modeling. Finally, discharge estimates based on regression equations relating peak discharge to the volume and depth of the impounded water, although limited by constraining assumptions, provide results within the range of values determined by the other methods. The discovery and documentation of a flood, caused by the failure of the caldera rim at Aniakchak caldera, underscore the significance and associated hydrologic hazards of potential large floods at other lake-filled calderas.
Studies on sildenafil citrate (Viagra) interaction with DNA using electrochemical DNA biosensor.
Rauf, Sakandar; Nawaz, Haq; Akhtar, Kalsoom; Ghauri, Muhammad A; Khalid, Ahmad M
2007-05-15
The interaction of sildenafil citrate (Viagra) with DNA was studied by using an electrochemical DNA biosensor. The binding mechanism of sildenafil citrate was elucidated by using constant current potentiometry and differential pulse voltammetry at DNA-modified glassy carbon electrode. The decrease in the guanine oxidation peak area or peak current was used as an indicator for the interaction in 0.2M acetate buffer (pH 5). The binding constant (K) values obtained were 2.01+/-0.05 x 10(5) and 1.97+/-0.01 x 10(5)M(-1) with constant current potentiometry and differential pulse voltammetry, respectively. A linear dependence of the guanine peak area or peak current was observed within the range of 1-40 microM sildenafil citrate with slope=-2.74 x 10(-4)s/microM, r=0.989 and slope=-2.78 x 10(-3)microA/microM, r=0.995 by using constant current potentiometry and differential pulse voltammetry, respectively. Additionally, binding constant values for sildenafil citrate-DNA interaction were determined for the pH range of 4-8 and in biological fluids (serum and urine) at pH 5. The influence of sodium and calcium ions was also studied to elucidate the mechanism of sildenafil citrate-DNA interaction under different solution conditions. The present study may prove to be helpful in extending our understanding of the anticancer activity of sildenafil citrate from cellular to DNA level.
NASA Astrophysics Data System (ADS)
Lv, Yan; Li, Xiang; Xu, Ting Ting; Cheng, Tian Tao; Yang, Xin; Chen, Jian Min; Iinuma, Yoshiteru; Herrmann, Hartmut
2016-03-01
In order to better understand the particle size distribution of polycyclic aromatic hydrocarbons (PAHs) and their source contribution to human respiratory system, size-resolved PAHs have been studied in ambient aerosols at a megacity Shanghai site during a 1-year period (2012-2013). The results showed the PAHs had a bimodal distribution with one mode peak in the fine-particle size range (0.4-2.1 µm) and another mode peak in the coarse-particle size range (3.3-9.0 µm). Along with the increase in ring number of PAHs, the intensity of the fine-mode peak increased, while the coarse-mode peak decreased. Plotting of log(PAH / PM) against log(Dp) showed that all slope values were above -1, suggesting that multiple mechanisms (adsorption and absorption) controlled the particle size distribution of PAHs. The total deposition flux of PAHs in the respiratory tract was calculated as being 8.8 ± 2.0 ng h-1. The highest lifetime cancer risk (LCR) was estimated at 1.5 × 10-6, which exceeded the unit risk of 10-6. The LCR values presented here were mainly influenced by accumulation mode PAHs which came from biomass burning (24 %), coal combustion (25 %), and vehicular emission (27 %). The present study provides us with a mechanistic understanding of the particle size distribution of PAHs and their transport in the human respiratory system, which can help develop better source control strategies.
Testosterone Trajectories and Reference Ranges in a Large Longitudinal Sample of Male Adolescents
Khairullah, Ammar; Cousino Klein, Laura; Ingle, Suzanne M.; May, Margaret T.; Whetzel, Courtney A.; Susman, Elizabeth J.; Paus, Tomáš
2014-01-01
Purpose Pubertal dynamics plays an important role in physical and psychological development of children and adolescents. We aim to provide reference ranges of plasma testosterone in a large longitudinal sample. Furthermore, we describe a measure of testosterone trajectories during adolescence that can be used in future investigations of development. Methods We carried out longitudinal measurements of plasma testosterone in 2,216 samples obtained from 513 males (9 to 17 years of age) from the Avon Longitudinal Study of Parents and Children. We used integration of a model fitted to each participant’s testosterone trajectory to calculate a measure of average exposure to testosterone over adolescence. We pooled these data with corresponding values reported in the literature to provide a reference range of testosterone levels in males between the ages of 6 and 19 years. Results The average values of total testosterone in the ALSPAC sample range from 0.82 nmol/L (Standard Deviation [SD]: 0.09) at 9 years of age to 16.5 (SD: 2.65) nmol/L at 17 years of age; these values are congruent with other reports in the literature. The average exposure to testosterone is associated with different features of testosterone trajectories such as Peak Testosterone Change, Age at Peak Testosterone Change, and Testosterone at 17 years of age as well as the timing of the growth spurt during puberty. Conclusions The average exposure to testosterone is a useful measure for future investigations using testosterone trajectories to examine pubertal dynamics. PMID:25268961
Investigation of a Gallium MPD Thruster with an Ablating Cathode
NASA Technical Reports Server (NTRS)
Thomas, Robert E.; Burton, Rodney L.; Polzin, Kurt A.
2010-01-01
Arc impedance, exhaust velocity, and plasma probe measurements are presented. The thruster is driven by a 50 microsecond pulse from a 6.2 milliohm pulse forming network, and gallium is supplied to the discharge by evaporation of the cathode. The arc voltage is found to vary linearly with the discharge current with an arc impedance of 6.5 milliohms. Electrostatic probes yield an exhaust velocity that is invariant with the discharge current and has a peak value of 20 kilometers per second, which is in reasonable agreement with the value (16 plus or minus 1 kilometer per second) calculated from the mass bit and discharge current data. Triple probe measurements yield on axis electron temperatures in the range of 0.8-3.8 eV, electron densities in the range of 1.6 x 10(exp 21) to 2.1 x 10(exp 22) per cubic meter, and a divergence half angle of 16 degrees. Measurements within the interelectrode region yield a peak magnetic field of 0.8 T, and the observed radial trends are consistent with an azimuthally symmetric current distribution. A cathode power balance model is coupled with an ablative heat conduction model predicting mass bit values that are within 20% of the experimental values.
Feasibility study of parallel optical correlation-decoding analysis of lightning
DOE Office of Scientific and Technical Information (OSTI.GOV)
Descour, M.R.; Sweatt, W.C.; Elliott, G.R.
The optical correlator described in this report is intended to serve as an attention-focusing processor. The objective is to narrowly bracket the range of a parameter value that characterizes the correlator input. The input is a waveform collected by a satellite-borne receiver. In the correlator, this waveform is simultaneously correlated with an ensemble of ionosphere impulse-response functions, each corresponding to a different total-electron-count (TEC) value. We have found that correlation is an effective method of bracketing the range of TEC values likely to be represented by the input waveform. High accuracy in a computational sense is not required of themore » correlator. Binarization of the impulse-response functions and the input waveforms prior to correlation results in a lower correlation-peak-to-background-fluctuation (signal-to-noise) ratio than the peak that is obtained when all waveforms retain their grayscale values. The results presented in this report were obtained by means of an acousto-optic correlator previously developed at SNL as well as by simulation. An optical-processor architecture optimized for 1D correlation of long waveforms characteristic of this application is described. Discussions of correlator components, such as optics, acousto-optic cells, digital micromirror devices, laser diodes, and VCSELs are included.« less
NASA Astrophysics Data System (ADS)
Zuo, Weiguang; Liu, Ming; Fan, Tianhui; Wang, Pengtao
2018-06-01
This paper presents the probability distribution of the slamming pressure from an experimental study of regular wave slamming on an elastically supported horizontal deck. The time series of the slamming pressure during the wave impact were first obtained through statistical analyses on experimental data. The exceeding probability distribution of the maximum slamming pressure peak and distribution parameters were analyzed, and the results show that the exceeding probability distribution of the maximum slamming pressure peak accords with the three-parameter Weibull distribution. Furthermore, the range and relationships of the distribution parameters were studied. The sum of the location parameter D and the scale parameter L was approximately equal to 1.0, and the exceeding probability was more than 36.79% when the random peak was equal to the sample average during the wave impact. The variation of the distribution parameters and slamming pressure under different model conditions were comprehensively presented, and the parameter values of the Weibull distribution of wave-slamming pressure peaks were different due to different test models. The parameter values were found to decrease due to the increased stiffness of the elastic support. The damage criterion of the structure model caused by the wave impact was initially discussed, and the structure model was destroyed when the average slamming time was greater than a certain value during the duration of the wave impact. The conclusions of the experimental study were then described.
Zhang, Wenfeng; Su, Qingyong; Xu, Mi; Yan, Wei
2015-09-01
The stress relaxation curves for three different hot deformation processes in the temperature range of 750-1000 °C were studied to develop an understanding of the precipitation behavior in a nitride-strengthened martensitic heat resistant steel (Zhang et al., Mater. Sci. Eng. A, 2015) [1]. This data article provides supporting data and detailed information on how to accurately analysis the stress relaxation data. The statistical analysis of the stress peak curves, including the number of peaks, the intensity of the peaks and the integral value of the pumps, was carried out. Meanwhile, the XRD energy spectrum data was also calculated in terms of lattice distortion.
Boker, Steven M; Xu, Minquan; Rotondo, Jennifer L; King, Kadijah
2002-09-01
Cross-correlation and most other longitudinal analyses assume that the association between 2 variables is stationary. Thus, a sample of occasions of measurement is expected to be representative of the association between variables regardless of the time of onset or number of occasions in the sample. The authors propose a method to analyze the association between 2 variables when the assumption of stationarity may not be warranted. The method results in estimates of both the strength of peak association and the time lag when the peak association occurred for a range of starting values of elapsed time from the beginning of an experiment.
Zhang, Wenfeng; Su, Qingyong; Xu, Mi; Yan, Wei
2015-01-01
The stress relaxation curves for three different hot deformation processes in the temperature range of 750–1000 °C were studied to develop an understanding of the precipitation behavior in a nitride-strengthened martensitic heat resistant steel (Zhang et al., Mater. Sci. Eng. A, 2015) [1]. This data article provides supporting data and detailed information on how to accurately analysis the stress relaxation data. The statistical analysis of the stress peak curves, including the number of peaks, the intensity of the peaks and the integral value of the pumps, was carried out. Meanwhile, the XRD energy spectrum data was also calculated in terms of lattice distortion. PMID:26306310
Liquefaction at Oceano, California, during the 2003 San Simeon earthquake
Holzer, T.L.; Noce, T.E.; Bennett, M.J.; Tinsley, J. C.; Rosenberg, L.I.
2005-01-01
The 2003 M 6.5 San Simeon, California, earthquake caused liquefaction-induced lateral spreading at Oceano at an unexpectedly large distance from the seismogenic rupture. We conclude that the liquefaction was caused by ground motion that was enhanced by both rupture directivity in the mainshock and local site amplification by unconsolidated fine-grained deposits. Liquefaction occurred in sandy artificial fill and undisturbed eolian sand and fluvial deposits. The largest and most damaging lateral spread was caused by liquefaction of artificial fill; the head of this lateral spread coincided with the boundary between the artificial fill and undisturbed eolian sand deposits. Values of the liquefaction potential index, in general, were greater than 5 at liquefaction sites, the threshold value that has been proposed for liquefaction hazard mapping. Although the mainshock ground motion at Oceano was not recorded, peak ground acceleration was estimated to range from 0.25 and 0.28g on the basis of the liquefaction potential index and aftershock recordings. The estimates fall within the range of peak ground acceleration values associated with the modified Mercalli intensity = VII reported at the U.S. Geological Survey (USGS) "Did You Feel It?" web site.
Analysis of electromagnetic fields on an F-106B aircraft during lightning strikes
NASA Technical Reports Server (NTRS)
Trost, T. F.; Pitts, F. L.
1982-01-01
Information on the exterior electromagnetic environment of an aircraft when it is struck by lightning has been obtained during thunderstorm penetrations with an F-106B aircraft. Electric and magnetic fields were observed, using mainly time-derivative type sensors, with bandwidths to 50 MHz. Lightning pulse lengths ranging from 25 ns to 7 microsec have been recorded. Sufficient high-frequency content was present to excite electromagnetic resonances of the aircraft, and peaks in the frequency spectra of the waveforms in the range 7 to 23 MHz are in agreement with the resonant frequencies determined in laboratory scale-model tests. Both positively and negatively charged strikes were experienced, and most of the data suggest low values of peak current.
Estimation of Seismic Attenuation beneath Tateyama Volcano, Central Japan by Using Peak Delay
NASA Astrophysics Data System (ADS)
Iwata, K.; Kawakata, H.; Hirano, S.; Doi, I.
2015-12-01
The Hida Mountain Range located in central Japan has a lot of active volcanoes. Katsumata et al. (1995, GJI) suggested the presence of regions with low-velocity and low-density as well as low Qanomaly at 5-15 km deep beneath the range. Tateyama volcano is located in the northern part of the range. Iwata et al. (2014, AGU Fall Meeting) quantitatively estimated strength of S-wave attenuation beneath Tateyama volcano using twofold spectral ratios and suggested that regions with high seismic attenuation exist in the south or the southeast of Tateyama volcano. However, it is difficult to estimate the contribution of scattering loss and intrinsic absorption to total attenuation on the basis of this method. In the present study, we focused on the peak delay (Takahashi et al., 2007, GJI) in seismic envelopes. We used seismograms observed at five NIED Hi-net stations near Tateyama volcano for 31 local earthquakes (MJMA2.5-4.0). We found seismograms recorded after passing below the southern part of the Hida Mountain Range show longer peak delay than those recorded before passing below the region, while there are no clear difference in peak delay for pairs of seismograms before and after passing below Tateyama volcano. It suggests that causes of the attenuation beneath Tateyama volcano and the southern part of the Hida Mountain Range are different. We used the peak delay values to evaluate the strength of intrinsic absorption. We assumed that the difference of whole peak delay between two seismograms for the same earthquake was caused by intrinsic absorption beneath the region between the two seismic stations. Wecalculated the change in amplitude and peak delay on the basis of a theory suggested by Azimi et al. (1966, Izvestia, Earth Physics). In case of the two envelopes are quite similar to each other, we conclude that intrinsic absorption is a major cause of total attenuation. If not so, we need to take into account the contribution of scattering attenuation and some others.
Perez, Richard
2005-05-03
A load controller and method are provided for maximizing effective capacity of a non-controllable, renewable power supply coupled to a variable electrical load also coupled to a conventional power grid. Effective capacity is enhanced by monitoring power output of the renewable supply and loading, and comparing the loading against the power output and a load adjustment threshold determined from an expected peak loading. A value for a load adjustment parameter is calculated by subtracting the renewable supply output and the load adjustment parameter from the current load. This value is then employed to control the variable load in an amount proportional to the value of the load control parameter when the parameter is within a predefined range. By so controlling the load, the effective capacity of the non-controllable, renewable power supply is increased without any attempt at operational feedback control of the renewable supply.
Kehmeier, Eva S; Sommer, Margot H; Galonska, Anika; Zeus, Tobias; Verde, Pablo; Kelm, Malte
2016-01-15
Exercise testing for the assessment of functional capacity plays an important role in long-term follow-up of GUCH patients. CPX is the favored modality for decision-making recommended in the current guidelines. In contrast to this complex method, the 6 MWT is a simple, easy-to-perform, safe, and commonly available exercise test. Although well-established in various cardiopulmonary diseases, the diagnostic impact of the 6 MWT in GUCH patients is not known so far. 102 GUCH patients were evaluated by 6 MWT and CPX simultaneously. Clinical symptoms were assessed, according to the NYHA classification. Additionally, an echocardiography study, and selected cardiac blood tests (N-terminal pro-brain natriuretic peptide (NT-proBNP), high-sensitive Troponin T) were performed. Ranges of six-minute walk distance (6 MWD) and peak oxygen consumption (peakVO2) were 116-765 m and 6.4-36.2 ml/kg/min, respectively. 6 MWD and peakVO2 showed a close correlation (r=0.72, 95% CI, 0.63 to 0.79). Patients with a peakVO2 of ≤ 15.5 ml/kg/min were excellently identified by 6 MWT (c-value=0.82). A cut-off value of 482 m was optimal to predict reduced peakVO2. In multivariate regression analysis, 6 MWD and NYHA class were identified as relevant predictors of peakVO2. In subgroup analysis, Eisenmenger patients achieved the shortest 6 MWD (280, SD 178 m). In our study population of GUCH patients, the 6 MWD shows a close correlation to peakVO2, and an excellent prediction of reduced peakVO2. Thus, it seems to be an easy-to-perform and reliable screening parameter to evaluate functional capacity of these patients (Controlled Clinical Trials number, NCT02193243). Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Accuracy of mini peak flow meters in indicating changes in lung function in children with asthma.
Sly, P. D.; Cahill, P.; Willet, K.; Burton, P.
1994-01-01
OBJECTIVE--To assess whether mini flow meters used to measure peak expiratory flow can track changes in lung function and indicate clinically important changes. DESIGN--Comparison of measurements with a spirometer and different brands of mini flow meter; the meters were allocated to subjects haphazardly. SUBJECTS--12 boys with asthma aged 11 to 17 attending boarding school. MAIN OUTCOME MEASURES--Peak expiratory flow measured twice daily for three months with a spirometer and at least one of four brands of mini flow meter. RESULTS--The relation between changes in lung function measured with the spirometer and those measured with the mini flow meters was generally poor. In all, 26 episodes (range 1-3 in an individual child) of clinically important deterioration in lung function were detected from the records obtained with the spirometer. One mini flow meter detected six of 19 episodes, one detected six of 15, one detected six of 18, and one detected three of 21. CONCLUSIONS--Not only are the absolute values of peak expiratory flow obtained with mini flow meters inaccurate but the clinical message may also be incorrect. These findings do not imply that home monitoring of peak expiratory flow has no place in the management of childhood asthma but that the values obtained should be interpreted cautiously. PMID:8148680
[Experimental and clinical evaluation latamoxef in newborn and premature infants].
Toyonaga, Y; Kurosu, Y; Sugita, M; Kitagawa, M; Hori, M
1983-09-01
Basic and clinical studies of latamoxef (LMOX) were carried out in neonates. In basic study, these neonates consisted of 16 mature babies and 12 premature babies. LMOX was administered at dose of 10 and 20 mg/kg, either as a single intravenous injection or as a 60 minutes intravenous drip infusion. Both the mature babies and the premature babies were divided into 3 subgroups as a function of the number of days after birth (0--3, 4--7 and 8--25 days). A clinical study of LMOX was performed in 12 neonates aged between 0--35 days, consisting 6 males and 6 females. (Purulent meningitis 4 cases, septicemia 1 case, bronchopneumonia 5 cases, pertussis pneumonia 1 case, urinary tract infection 1 case). Serum concentration and urinary excretion 10 mg/kg, one shot intravenous injection In the 3 subgroups of neonates the peak serum concentrations of LMOX were found to range from 14.6 to 28.9 micrograms/ml. Although there was no significant difference, the half-life of the drug became shorter as the age of the neonates increased, these values were 4.46, 3.85 and 3.30 hours, respectively. 10 mg/kg, 60 minutes intravenous drip infusion. As above, the peak LMOX serum concentrations were found to range from 23.7 to 38.9 micrograms/ml, the half-lives of the 3 subgroups were 4.83, 2.48 and 3.01 hours, respectively. And urinary excretions were ranged from 46.0 to 56.5% for 6 hours. 20 mg/kg, one shot intravenous injection The peak serum concentrations were found to range from 31.0--82.5 micrograms/ml, and it was found out 3.29--15.9 micrograms/ml at 8 hours after the injection. There was a tendency for the half-life to be shorter in more mature subjects in 3 subgroups. 20 mg/kg, 60 minutes intravenous drip infusion In the 3 subgroups, the peak concentration was the level existing at the end of the intravenous drip infusion, and that showed a range of 41.8--58.6 micrograms/ml. Half-lives were found out the significant difference to their age, these showed 4.08, 2.31 and 2.52 hours. Cerebrospinal fluid concentrations of LMOX Cerebrospinal fluid concentrations of LMOX were studied in 2 cases at the dose about 50 mg/kg. In 1 case, that's meningitis estimated E. coli organism, the cerebrospinal fluid concentrations of LMOX were found to range from 29.0 to 49.9 micrograms/ml in that acute state. In another case from N. meningitidis, that values were found to range 12.1 to 21.3 micrograms/ml. These cerebrospinal levels were superior value at it's penetration ratio. Clinical studies.(ABSTRACT TRUNCATED AT 400 WORDS)
Marikkar, Jalaldeen Mohammed Nazrim; Rana, Sohel
2014-01-01
A study was conducted to detect and quantify lard stearin (LS) content in canola oil (CaO) using differential scanning calorimetry (DSC). Authentic samples of CaO were obtained from a reliable supplier and the adulterant LS were obtained through a fractional crystallization procedure as reported previously. Pure CaO samples spiked with LS in levels ranging from 5 to 15% (w/w) were analyzed using DSC to obtain their cooling and heating profiles. The results showed that samples contaminated with LS at 5% (w/w) level can be detected using characteristic contaminant peaks appearing in the higher temperature regions (0 to 70°C) of the cooling and heating curves. Pearson correlation analysis of LS content against individual DSC parameters of the adulterant peak namely peak temperature, peak area, peak onset temperature indicated that there were strong correlations between these with the LS content of the CaO admixtures. When these three parameters were engaged as variables in the execution of the stepwise regression procedure, predictive models for determination of LS content in CaO were obtained. The predictive models obtained with single DSC parameter had relatively lower coefficient of determination (R(2) value) and higher standard error than the models obtained using two DSC parameters in combination. This study concluded that the predictive models obtained with peak area and peak onset temperature of the adulteration peak would be more accurate for prediction of LS content in CaO based on the highest coefficient of determination (R(2) value) and smallest standard error.
NASA Astrophysics Data System (ADS)
Patel, Swarnim; Shrivas, Sandhya; Dubey, R. K.; Keller, J. M.
2018-05-01
Short circuit thermally stimulated depolarization current measurement techniques has been employed to investigate the dielectric relaxation behavior of PSF: PVDF blends. The samples taken were blends of composition PSF: PVDF:: 80:20; 85:15; 90:10 and 95:05 percent by weight. The thermograms were characterized by a high value of initial current, a low temperature peak around 75-80°C and a prominent broad peak in the temperature interval 130 to 160°C. The two polymers are found to form compatible blend in the studied composition range.
Wankhar, Wankupar; Srinivasan, Sakthivel; Rathinasamy, Sheeladevi
2015-01-01
This study evaluates the larvicidal activity of Scoparia dulcis aqueous extract against dengue vector and determines its major chemical components. The extract was tested at various concentrations ranging from 0.1 to 2 mg/mL against Aedes aegypti larvae. The extracts displayed significant larvicidal efficacy against Ae. aegypt species after 24 h exposure revealing LC50 of 3.3835 (mg/mL) and LC90 of 5.7578 (mg/mL). Finger printing profile carried out by CAMAG automatic TLC sample applicator programmed through WIN CATS software revealed peaks with different Rf values for three different volumes injected: 16, 15 and 18 peaks were spotted for 3, 6 and 9 μL, respectively. Ascending order of Rf values was also ascertained for each peak recorded. This study clearly signifies that S. dulcis extract contains numerous compounds that are known to have larvicidal properties which clearly substantiates its efficacy on Ae. aegypti larvae.
Dynamic Yielding and Spall Behavior of Commercially Pure Grade 4 Titanium
NASA Astrophysics Data System (ADS)
Thadhani, Naresh; Whelchel, R. L.; Sanders, Tom; Mehkote, D. S.; Iyer, K. A.; Georgia Instiutute of Technology Collaboration; Johns Hopkins University, Applied Physics Labortaory Collaboration
2015-06-01
The dynamic yielding and fracture (spalling) of commercially pure (grade 4) titanium are investigated using symmetric plate impact experiments over a peak stress range of 5.6 GPa to 12.5 GPa, using the 80-mm single-stage gas-gun. VISAR rear free surface velocity profiles display both a Hugoniot elastic limit (HEL) and a velocity pullback, which are indicative of dynamic compressive yielding and tensile fracture (spalling), respectively. The HEL values appear to show a slight decrease with peak stress from 2.2 GPa to 2.0 GPa along with a corresponding increase in twinning observed in recovered impacted samples. The spall strength on the other hand increases with peak stress from a value of 3.3 GPa to 3.8 GPa and shows a good power law fit with the decompression strain rate. The differing responses in dynamic yield and fracture behavior suggest that void nucleation may be the dominant mechanism affecting the spall strength of grade 4 titanium.
β-decay Rates for Exotic Nuclei and r-process Nucleosynthesis up to Thorium and Uranium
NASA Astrophysics Data System (ADS)
Suzuki, Toshio; Shibagaki, Shota; Yoshida, Takashi; Kajino, Toshitaka; Otsuka, Takaharu
2018-06-01
Beta-decay rates for exotic nuclei with neutron magic number of N = 126 relevant to r-process nucleosynthesis are studied up to Z = 78 by shell-model calculations. The half-lives for the waiting-point nuclei obtained, which are short compared to a standard finite-range-droplet model, are used to study r-process nucleosynthesis in core-collapse supernova (CCSN) explosions and binary neutron star mergers. The element abundances are obtained up to the third peak as well as beyond the peak region up to thorium and uranium. The position of the third peak is found to be shifted toward a higher mass region in both CCSN explosions and neutron star mergers. We find that thorium and uranium elements are produced more with the shorter shell-model half-lives and their abundances come close to the observed values in CCSN explosions. In the case of binary neutron star mergers, thorium and uranium are produced consistently with the observed values independent of the half-lives.
Dvořák, Martin; Svobodová, Jana; Dubský, Pavel; Riesová, Martina; Vigh, Gyula; Gaš, Bohuslav
2015-03-01
Although the classical formula of peak resolution was derived to characterize the extent of separation only for Gaussian peaks of equal areas, it is often used even when the peaks follow non-Gaussian distributions and/or have unequal areas. This practice can result in misleading information about the extent of separation in terms of the severity of peak overlap. We propose here the use of the equivalent peak resolution value, a term based on relative peak overlap, to characterize the extent of separation that had been achieved. The definition of equivalent peak resolution is not constrained either by the form(s) of the concentration distribution function(s) of the peaks (Gaussian or non-Gaussian) or the relative area of the peaks. The equivalent peak resolution value and the classically defined peak resolution value are numerically identical when the separated peaks are Gaussian and have identical areas and SDs. Using our new freeware program, Resolution Analyzer, one can calculate both the classically defined and the equivalent peak resolution values. With the help of this tool, we demonstrate here that the classical peak resolution values mischaracterize the extent of peak overlap even when the peaks are Gaussian but have different areas. We show that under ideal conditions of the separation process, the relative peak overlap value is easily accessible by fitting the overall peak profile as the sum of two Gaussian functions. The applicability of the new approach is demonstrated on real separations. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
The value of demand response in Florida
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stoll, Brady; Buechler, Elizabeth; Hale, Elaine
Many electrical loads may be operated flexibly to provide grid services, including peaking capacity, reserves, and load shifting. The authors model 14 demand end uses in Florida and analyze their operational impacts and overall value for a wide range of solar penetrations and grid flexibility options. They find demand response is able to reduce production costs, reduce the number of low-load hours for traditional generators, reduce starting of gas generators, and reduce curtailment.
The value of demand response in Florida
Stoll, Brady; Buechler, Elizabeth; Hale, Elaine
2017-11-10
Many electrical loads may be operated flexibly to provide grid services, including peaking capacity, reserves, and load shifting. The authors model 14 demand end uses in Florida and analyze their operational impacts and overall value for a wide range of solar penetrations and grid flexibility options. They find demand response is able to reduce production costs, reduce the number of low-load hours for traditional generators, reduce starting of gas generators, and reduce curtailment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
2016-11-30
The PeakWorks software is designed to assist in the quantitative analysis of atom probe tomography (APT) generated mass spectra. Specifically, through an interactive user interface, mass peaks can be identified automatically (defined by a threshold) and/or identified manually. The software then provides a means to assign specific elemental isotopes (including more than one) to each peak. The software also provides a means for the user to choose background subtraction of each peak based on background fitting functions, the choice of which is left to the users discretion. Peak ranging (the mass range over which peaks are integrated) is also automatedmore » allowing the user to chose a quantitative range (e.g. full-widthhalf- maximum). The software then integrates all identified peaks, providing a background-subtracted composition, which also includes the deconvolution of peaks (i.e. those peaks that happen to have overlapping isotopic masses). The software is also able to output a 'range file' that can be used in other software packages, such as within IVAS. A range file lists the peak identities, the mass range of each identified peak, and a color code for the peak. The software is also able to generate 'dummy' peak ranges within an outputted range file that can be used within IVAS to provide a means for background subtracted proximity histogram analysis.« less
NASA Astrophysics Data System (ADS)
Rogers, A. M.; Harmsen, S. C.; Herrmann, R. B.; Meremonte, M. E.
1987-04-01
As a first step in the assessment of the earthquake hazard in the southern Great Basin of Nevada-California, this study evaluates the attenuation of peak vertical ground motions using a number of different regression models applied to unfiltered and band-pass-filtered ground motion data. These data are concentrated in the distance range 10-250 km. The regression models include parameters to account for geometric spreading, anelastic attenuation with a power law frequency dependence, source size, and station site effects. We find that the data are most consistent with an essentially frequency-independent Q and a geometric spreading coefficient less than 1.0. Regressions are also performed on vertical component peak amplitudes reexpressed as pseudo-Wood-Anderson peak amplitude estimates (PWA), permitting comparison with earlier work that used Wood-Anderson (WA) data from California. Both of these results show that Q values in this region are high relative to California, having values in the range 700-900 over the frequency band 1-10 Hz. Comparison of ML magnitudes from stations BRK and PAS for earthquakes in the southern Great Basin shows that these two stations report magnitudes with differences that are distance dependent. This bias suggests that the Richter log A0 curve appropriate to California is too steep for earthquakes occurring in southern Nevada, a result implicitly supporting our finding that Q values are higher than those in California. The PWA attenuation functions derived from our data also indicate that local magnitudes reported by California observatories for earthquakes in this region may be overestimated by as much as 0.8 magnitude units in some cases. Both of these results will have an effect on the assessment of the earthquake hazard in this region. The robustness of our regression technique to extract the correct geometric spreading coefficient n and anelastic attenuation Q is tested by applying the technique to simulated data computed with given n and Q values. Using a stochastic modeling technique, we generate suites of seismograms for the distance range 10-200 km and for both WA and short-period vertical component seismometers. Regressions on the peak amplitudes from these records show that our regression model extracts values of n and Q approximately equal to the input values for either low-Q California attenuation or high-Q southern Nevada attenuation. Regressions on stochastically modeled WA and PWA amplitudes also provides a method of evaluating differences in magnitudes from WA and PWA amplitudes due to recording instrument response characteristics alone. These results indicate a difference between MLWA and MLPWA equal to 0.15 magnitude units, which we term the residual instrument correction. In contrast to the peak amplitude results, coda Q determinations using the single scatterer theory indicate that Qc values are dependent on source type and are proportional to ƒp, where p = 0.8 to 1.0. This result suggests that a difference exists between attenuation mechanisms for direct waves and backscattered waves in this region.
Prediction of plantar shear stress distribution by artificial intelligence methods.
Yavuz, Metin; Ocak, Hasan; Hetherington, Vincent J; Davis, Brian L
2009-09-01
Shear forces under the human foot are thought to be responsible for various foot pathologies such as diabetic plantar ulcers and athletic blisters. Frictional shear forces might also play a role in the metatarsalgia observed among hallux valgus (HaV) and rheumatoid arthritis (RA) patients. Due to the absence of commercial devices capable of measuring shear stress distribution, a number of linear models were developed. All of these have met with limited success. This study used nonlinear methods, specifically neural network and fuzzy logic schemes, to predict the distribution of plantar shear forces based on vertical loading parameters. In total, 73 subjects were recruited; 17 had diabetic neuropathy, 14 had HaV, 9 had RA, 11 had frequent foot blisters, and 22 were healthy. A feed-forward neural network (NN) and adaptive neurofuzzy inference system (NFIS) were built. These systems were then applied to a custom-built platform, which collected plantar pressure and shear stress data as subjects walked over the device. The inputs to both models were peak pressure, peak pressure-time integral, and time to peak pressure, and the output was peak resultant shear. Root-mean-square error (RMSE) values were calculated to test the models' accuracy. RMSE/actual shear ratio varied between 0.27 and 0.40 for NN predictions. Similarly, NFIS estimations resulted in a 0.28-0.37 ratio for local peak values in all subject groups. On the other hand, error percentages for global peak shear values were found to be in the range 11.4-44.1. These results indicate that there is no direct relationship between pressure and shear magnitudes. Future research should aim to decrease error levels by introducing shear stress dependent variables into the models.
Swanson, William H.; Horner, Douglas G.; Dul, Mitchell W.; Malinovsky, Victor E.
2014-01-01
Purpose To develop guidelines for engineering perimetric stimuli to reduce test-retest variability in glaucomatous defects. Methods Perimetric testing was performed on one eye for 62 patients with glaucoma and 41 age-similar controls on size III and frequency-doubling perimetry and three custom tests with Gaussian blob and Gabor sinusoid stimuli. Stimulus range was controlled by values for ceiling (maximum sensitivity) and floor (minimum sensitivity). Bland-Altman analysis was used to derive 95% limits of agreement on test and retest, and bootstrap analysis was used to test the hypotheses about peak variability. Results Limits of agreement for the three custom stimuli were similar in width (0.72 to 0.79 log units) and peak variability (0.22 to 0.29 log units) for a stimulus range of 1.7 log units. The width of the limits of agreement for size III decreased from 1.78 to 1.37 to 0.99 log units for stimulus ranges of 3.9, 2.7, and 1.7 log units, respectively (F = 3.23, P < 0.001); peak variability was 0.99, 0.54, and 0.34 log units, respectively (P < 0.01). For a stimulus range of 1.3 log units, limits of agreement were narrowest with Gabor and widest with size III stimuli, and peak variability was lower (P < 0.01) with Gabor (0.18 log units) and frequency-doubling perimetry (0.24 log units) than with size III stimuli (0.38 log units). Conclusions Test-retest variability in glaucomatous visual field defects was substantially reduced by engineering the stimuli. Translational Relevance The guidelines should allow developers to choose from a wide range of stimuli. PMID:25371855
Swanson, William H; Horner, Douglas G; Dul, Mitchell W; Malinovsky, Victor E
2014-09-01
To develop guidelines for engineering perimetric stimuli to reduce test-retest variability in glaucomatous defects. Perimetric testing was performed on one eye for 62 patients with glaucoma and 41 age-similar controls on size III and frequency-doubling perimetry and three custom tests with Gaussian blob and Gabor sinusoid stimuli. Stimulus range was controlled by values for ceiling (maximum sensitivity) and floor (minimum sensitivity). Bland-Altman analysis was used to derive 95% limits of agreement on test and retest, and bootstrap analysis was used to test the hypotheses about peak variability. Limits of agreement for the three custom stimuli were similar in width (0.72 to 0.79 log units) and peak variability (0.22 to 0.29 log units) for a stimulus range of 1.7 log units. The width of the limits of agreement for size III decreased from 1.78 to 1.37 to 0.99 log units for stimulus ranges of 3.9, 2.7, and 1.7 log units, respectively ( F = 3.23, P < 0.001); peak variability was 0.99, 0.54, and 0.34 log units, respectively ( P < 0.01). For a stimulus range of 1.3 log units, limits of agreement were narrowest with Gabor and widest with size III stimuli, and peak variability was lower ( P < 0.01) with Gabor (0.18 log units) and frequency-doubling perimetry (0.24 log units) than with size III stimuli (0.38 log units). Test-retest variability in glaucomatous visual field defects was substantially reduced by engineering the stimuli. The guidelines should allow developers to choose from a wide range of stimuli.
Submicrosecond characteristics of lightning return-stroke currents
NASA Technical Reports Server (NTRS)
Leteinturier, Christiane; Hamelin, Joel H.; Eybert-Berard, Andre
1991-01-01
The authors describe the experimental results obtained during 1987 and 1988 triggered-lightning experiments in Florida. Seventy-four simultaneous submicrosecond time-resolved measurements of triggered return-stroke current (I) and current derivative (dI/dt) were made in Florida in 1987 and 1988. Peak currents ranged from about 5 to 76 kA, peak dI/dt amplitude from 13 to 411 kA/microsec and rise time from 90 to 1000 ns. The mean peak dI/dt values of 110 kA/microsec were 2-3 times higher than data from instrumented towers and peak I and dI/dt appear to be positively correlated. These data confirm previous experiments and conclusions supported by forty measurements. They are important in order to define, for example, standards for lightning protection. Present standards give a dI/dt maximum of 140 kA/microsec.
The evaluation of speed skating helmet performance through peak linear and rotational accelerations.
Karton, Clara; Rousseau, Philippe; Vassilyadi, Michael; Hoshizaki, Thomas Blaine
2014-01-01
Like many sports involving high speeds and body contact, head injuries are a concern for short track speed skating athletes and coaches. While the mandatory use of helmets has managed to nearly eliminate catastrophic head injuries such as skull fractures and cerebral haemorrhages, they may not be as effective at reducing the risk of a concussion. The purpose of this study was to evaluate the performance characteristics of speed skating helmets with respect to managing peak linear and peak rotational acceleration, and to compare their performance against other types of helmets commonly worn within the speed skating sport. Commercially available speed skating, bicycle and ice hockey helmets were evaluated using a three-impact condition test protocol at an impact velocity of 4 m/s. Two speed skating helmet models yielded mean peak linear accelerations at a low-estimated probability range for sustaining a concussion for all three impact conditions. Conversely, the resulting mean peak rotational acceleration values were all found close to the high end of a probability range for sustaining a concussion. A similar tendency was observed for the bicycle and ice hockey helmets under the same impact conditions. Speed skating helmets may not be as effective at managing rotational acceleration and therefore may not successfully protect the user against risks associated with concussion injuries.
Eltoukhy, Moataz; Kelly, Adam; Kim, Chang-Young; Jun, Hyung-Pil; Campbell, Richard; Kuenze, Christopher
2016-01-01
Cost effective, quantifiable assessment of lower extremity movement represents potential improvement over standard tools for evaluation of injury risk. Ten healthy participants completed three trials of a drop jump, overhead squat, and single leg squat task. Peak hip and knee kinematics were assessed using an 8 camera BTS Smart 7000DX motion analysis system and the Microsoft Kinect® camera system. The agreement and consistency between both uncorrected and correct Kinect kinematic variables and the BTS camera system were assessed using interclass correlations coefficients. Peak sagittal plane kinematics measured using the Microsoft Kinect® camera system explained a significant amount of variance [Range(hip) = 43.5-62.8%; Range(knee) = 67.5-89.6%] in peak kinematics measured using the BTS camera system. Across tasks, peak knee flexion angle and peak hip flexion were found to be consistent and in agreement when the Microsoft Kinect® camera system was directly compared to the BTS camera system but these values were improved following application of a corrective factor. The Microsoft Kinect® may not be an appropriate surrogate for traditional motion analysis technology, but it may have potential applications as a real-time feedback tool in pathological or high injury risk populations.
Fabrication of organic solar cells with design blend P3HT: PCBM variation of mass ratio
NASA Astrophysics Data System (ADS)
Supriyanto, Agus; Mustaqim, Amrina; Agustin, Maya; Ramelan, Ari H.; Suyitno; Septa Rosa, Erlyta; Yofentina; Nurosyid, Fahru
2016-02-01
Organic solar cells of FTO/PEDOT: PSS/P3HT: PCBM/Al has been fabricated, and its performance has been tested in dark and under various illumination of light intensity 1000 W/m2. The active materials used in this study are poly (3- hexylthiophene) (P3HT) and [6, 6]-phenyl-C61-butyric acid methyl ester (PCBM). P3HT is the donor while PCBM acts as an acceptor. Variation of PCBM and P3HT are 1:1, 1:2, 1:3, 1:4 and 1:5. P3HT: PCBM was mixed by chlorobenzene solvents. The mixing was done by using the ultrasonic cleaner. The absorbance characterization using by UV-Visible Spectrometer Lambda 25 instrument and I-V characterization has been tested using a set of 2602A Keithley instrument. Absorbance characterization shows that two peaks are formed. The first peak in the range of 300 to 350 nm which is a range of PCBM and the second peak range from 450 to 600 nm which is a range of P3HT. As the mass ratio increases, the second peak of P3HT increases while the first peak does not change. The gap energy estimated by the Tauc method is 2.0 eV. I-V characterization of the efficiency was obtained. The efficiency of sample 1, 2, 3, 4, and 5 are 5.80x10-2%; 6.46x10-2%; 7.72x10-2%; 8.25x10-2% and 9.81x10-2%, respectively. The highest value of efficiency was obtained at mass ratio 1:5.
Smith, S. Jerrod; Lewis, Jason M.; Graves, Grant M.
2015-09-28
Generalized-least-squares multiple-linear regression analysis was used to formulate regression relations between peak-streamflow frequency statistics and basin characteristics. Contributing drainage area was the only basin characteristic determined to be statistically significant for all percentage of annual exceedance probabilities and was the only basin characteristic used in regional regression equations for estimating peak-streamflow frequency statistics on unregulated streams in and near the Oklahoma Panhandle. The regression model pseudo-coefficient of determination, converted to percent, for the Oklahoma Panhandle regional regression equations ranged from about 38 to 63 percent. The standard errors of prediction and the standard model errors for the Oklahoma Panhandle regional regression equations ranged from about 84 to 148 percent and from about 76 to 138 percent, respectively. These errors were comparable to those reported for regional peak-streamflow frequency regression equations for the High Plains areas of Texas and Colorado. The root mean square errors for the Oklahoma Panhandle regional regression equations (ranging from 3,170 to 92,000 cubic feet per second) were less than the root mean square errors for the Oklahoma statewide regression equations (ranging from 18,900 to 412,000 cubic feet per second); therefore, the Oklahoma Panhandle regional regression equations produce more accurate peak-streamflow statistic estimates for the irrigated period of record in the Oklahoma Panhandle than do the Oklahoma statewide regression equations. The regression equations developed in this report are applicable to streams that are not substantially affected by regulation, impoundment, or surface-water withdrawals. These regression equations are intended for use for stream sites with contributing drainage areas less than or equal to about 2,060 square miles, the maximum value for the independent variable used in the regression analysis.
Comparison of five portable peak flow meters
Takara, Glaucia Nency; Ruas, Gualberto; Pessoa, Bruna Varanda; Jamami, Luciana Kawakami; Di Lorenzo, Valéria Amorim Pires; Jamami, Mauricio
2010-01-01
OBJECTIVE To compare the measurements of spirometric peak expiratory flow (PEF) from five different PEF meters and to determine if their values are in agreement. Inaccurate equipment may result in incorrect diagnoses of asthma and inappropriate treatments. METHODS Sixty-eight healthy, sedentary and insufficiently active subjects, aged from 19 to 40 years, performed PEF measurements using Air Zone®, Assess®, Galemed®, Personal Best® and Vitalograph® peak flow meters. The highest value recorded for each subject for each device was compared to the corresponding spirometric values using Friedman’s test with Dunn’s post-hoc (p<0.05), Spearman’s correlation test and Bland-Altman’s agreement test. RESULTS The median and interquartile ranges for the spirometric values and the Air Zone®, Assess®, Galemed®, Personal Best® and Vitalograph® meters were 428 (263–688 L/min), 450 (350–800 L/min), 420 (310–720 L/min), 380 (300–735 L/min), 400 (310–685 L/min) and 415 (335–610 L/min), respectively. Significant differences were found when the spirometric values were compared to those recorded by the Air Zone® (p<0.001) and Galemed ® (p<0.01) meters. There was no agreement between the spirometric values and the five PEF meters. CONCLUSIONS The results suggest that the values recorded from Galemed® meters may underestimate the actual value, which could lead to unnecessary interventions, and that Air Zone® meters overestimate spirometric values, which could obfuscate the need for intervention. These findings must be taken into account when interpreting both devices’ results in younger people. These differences should also be considered when directly comparing values from different types of PEF meters. PMID:20535364
Experimental simulation of impact cratering on icy satellites
NASA Technical Reports Server (NTRS)
Greeley, R.; Fink, J. H.; Gault, D. E.; Guest, J. E.
1982-01-01
Cratering processes on icy satellites were simulated in a series of 102 laboratory impact experiments involving a wide range of target materials. For impacts into homogeneous clay slurries with impact energies ranging from five million to ten billion ergs, target yield strengths ranged from 100 to 38 Pa, and apparent viscosities ranged from 8 to 200 Pa s. Bowl-shaped craters, flat-floored craters, central peak craters with high or little relief, and craters with no relief were observed. Crater diameters increased steadily as energies were raised. A similar sequence was seen for experiment in which impact energy was held constant but target viscosity and strength progressively decreases. The experiments suggest that the physical properties of the target media relative to the gravitationally induced stresses determined the final crater morphology. Crater palimpsests could form by prompt collapse of large central peak craters formed in low target strength materials. Ages estimated from crater size-frequency distributions that include these large craters may give values that are too high.
NASA Astrophysics Data System (ADS)
Luo, Haibo; Teng, Jie; Chen, Shuang; Wang, Yu; Zhang, Hui
2017-10-01
Hot compression tests of 8009Al alloy reinforced with 15% SiC particles (8009Al/15%SiCp composites) prepared by powder metallurgy (direct hot extrusion methods) were performed on Gleeble-3500 system in the temperature range of 400-550 °C and strain rate range of 0.001-1 s-1. The processing map based on the dynamic material model was established to evaluate the flow instability regime and optimize processing parameters; the associated microstructural changes were studied by the observations of optical metallographic and scanning electron microscopy. The results showed that the flow stress increased initially and reached a plateau after peak stress value with increasing strain. The peak stress increased as the strain rate increased and deformation temperature decreased. The optimum parameters were identified to be deformation temperature range of 500-550 °C and strain rate range of 0.001-0.02 s-1 by combining the processing map with microstructural observation.
NASA Technical Reports Server (NTRS)
Niedra, Janis M.; Schwarze, Gene E.
1999-01-01
100 kHz core loss properties of sample transverse magnetically annealed, cobalt-based amorphous and iron-based nanocrystalline tape wound magnetic cores are presented over the temperature range of -150 C to 150 C, at selected values of B(sub peak). For B-fields not close to saturation, the core loss is not sensitive to temperature in this range and is as low as seen in the best MnZn power ferrites at their optimum temperatures. Frequency resolved characteristics are given over the range of 50 kHz to 1 MHz, but at B(sub peak) = 0.1 T and 50 C only. For example, the 100 kHz specific core loss ranged from 50 - 70 mW/cubic cm for the 3 materials, when measured at 0.1 T and 50 C. This very low high frequency core loss, together with near zero saturation magnetostriction and insensitivity to rough handling, makes these amorphous ribbons strong candidates for power magnetics applications in wide temperature aerospace environments.
Method and apparatus for analog pulse pile-up rejection
De Geronimo, Gianluigi
2013-12-31
A method and apparatus for pulse pile-up rejection are disclosed. The apparatus comprises a delay value application constituent configured to receive a threshold-crossing time value, and provide an adjustable value according to a delay value and the threshold-crossing time value; and a comparison constituent configured to receive a peak-occurrence time value and the adjustable value, compare the peak-occurrence time value with the adjustable value, indicate pulse acceptance if the peak-occurrence time value is less than or equal to the adjustable value, and indicate pulse rejection if the peak-occurrence time value is greater than the adjustable value.
Method and apparatus for analog pulse pile-up rejection
De Geronimo, Gianluigi
2014-11-18
A method and apparatus for pulse pile-up rejection are disclosed. The apparatus comprises a delay value application constituent configured to receive a threshold-crossing time value, and provide an adjustable value according to a delay value and the threshold-crossing time value; and a comparison constituent configured to receive a peak-occurrence time value and the adjustable value, compare the peak-occurrence time value with the adjustable value, indicate pulse acceptance if the peak-occurrence time value is less than or equal to the adjustable value, and indicate pulse rejection if the peak-occurrence time value is greater than the adjustable value.
Kwon, Dongwook; Ko, Myoung-Soo; Yang, Jung-Seok; Kwon, Man Jae; Lee, Seung-Woo; Lee, Seunghak
2015-08-01
Hydrocarbons found in the environment are typically characterized by gas chromatography (GC). The shape of the GC chromatogram has been used to identify the source of petroleum contamination. However, the conventional practice of simply comparing the peak patterns of source products to those of environmental samples is dependent on the subjective decisions of individual analysts. We have developed and verified a quantitative analytical method for interpreting GC chromatograms to distinguish refined petroleum products in contaminated soils. We found that chromatograms for gasoline, kerosene, and diesel could be divided into three ranges with boundaries at C6, C8, C16, and C26. In addition, the relative peak area (RPA(GC)) of each range, a dimensionless ratio of the peak area within each range to that of the total range (C6-C26), had a unique value for each petroleum product. An identification index for GC chromatograms (ID(GC)), defined as the ratio of RPA(GC) of C8-C16 to that of C16-C26, was able to identify diesel and kerosene sources in samples extracted from artificially contaminated soils even after weathering. Thus, the ID(GC) can be used to effectively distinguish between refined petroleum products in contaminated soils.
Evaluation of hearing protection used by police officers in the shooting range.
Guida, Heraldo Lorena; Taxini, Carla Linhares; Gonçalves, Claudia Giglio de Oliveira; Valenti, Vitor Engrácia
2014-01-01
Impact noise is characterized by acoustic energy peaks that last less than a second, at intervals of more than 1s. To quantify the levels of impact noise to which police officers are exposed during activities at the shooting range and to evaluate the attenuation of the hearing protector. Measurements were performed in the shooting range of a military police department. An SV 102 audiodosimeter (Svantek) was used to measure sound pressure levels. Two microphones were used simultaneously: one external and one insertion type; the firearm used was a 0.40 Taurus® rimless pistol. The values obtained with the external microphone were 146 dBC (peak), and a maximum sound level of 129.4 dBC (fast). The results obtained with the insertion microphone were 138.7 dBC (peak), and a maximum sound level of 121.6 dBC (fast). The findings showed high levels of sound pressure in the shooting range, which exceeded the maximum recommended noise (120 dBC), even when measured through the insertion microphone. Therefore, alternatives to improve the performance of hearing protection should be considered. Copyright © 2014 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
Cannon, Susan H.; Gartner, Joseph E.; Rupert, Michael G.; Michael, John A.
2003-01-01
These maps present preliminary assessments of the probability of debris-flow activity and estimates of peak discharges that can potentially be generated by debris-flows issuing from basins burned by the Piru, Simi and Verdale Fires of October 2003 in southern California in response to the 25-year, 10-year, and 2-year 1-hour rain storms. The probability maps are based on the application of a logistic multiple regression model that describes the percent chance of debris-flow production from an individual basin as a function of burned extent, soil properties, basin gradients and storm rainfall. The peak discharge maps are based on application of a multiple-regression model that can be used to estimate debris-flow peak discharge at a basin outlet as a function of basin gradient, burn extent, and storm rainfall. Probabilities of debris-flow occurrence for the Piru Fire range between 2 and 94% and estimates of debris flow peak discharges range between 1,200 and 6,640 ft3/s (34 to 188 m3/s). Basins burned by the Simi Fire show probabilities for debris-flow occurrence between 1 and 98%, and peak discharge estimates between 1,130 and 6,180 ft3/s (32 and 175 m3/s). The probabilities for debris-flow activity calculated for the Verdale Fire range from negligible values to 13%. Peak discharges were not estimated for this fire because of these low probabilities. These maps are intended to identify those basins that are most prone to the largest debris-flow events and provide information for the preliminary design of mitigation measures and for the planning of evacuation timing and routes.
Simultaneous Planck, Swift, and Fermi Observations of X-Ray and gamma-Ray Selected Blazars
NASA Technical Reports Server (NTRS)
Giommi, P.; Polenta, G.; Laehteenmaeki, A.; Thompson, D. J.; Capalbi, M.; Cutini, S.; Gasparrini, D.; Gonzalez-Nuevo, J.; Leon-Tavares, J.; Lopez-Caniego, M.;
2011-01-01
We present simultaneous Planck, Swift, Fermi, and ground-based data for 105 blazars belonging to three samples with flux limits in the soft X-ray, hard X-ray, and -ray bands, and we compare our results to those of a companion paper presenting simultaneous Planck and multi-frequency observations of 104 radio-loud northern active galactic nuclei selected at radio frequencies. While we confirm several previous results, our unique data set has allowed us to demonstrate that the selection method strongly influences the results, producing biases that cannot be ignored. Almost all the BL Lac objects have been detected by Fermi Large Area Telescope (LAT), whereas 30 to 40% of the flat-spectrum radio quasars (FSRQs) in the radio, soft X-ray, and hard X-ray selected samples are still below the gamma ray detection limit even after integrating 27 months of Fermi-LAT data. The radio to sub-millimetre spectral slope of blazars is quite flat, with [alpha] approximately 0 up to about 70 GHz, above which it steepens to [alpha] approximately -0.65. BL Lacs have significantly flatter spectra than FSRQs at higher frequencies. The distribution of the rest-frame synchrotron peak frequency (v(sup IC) (sub (PEAK)), ranges from 10(sup 21) to 10(sup 22) HZ. The distribution of the rest-frame synchrotron peak frequency (v(sup s)(sub peak)) in the spectral energy distribution (SED) of FSRQs is the same in all the blazar samples with (v(sup s)(sub peak) = 10(sup 13:1 plus or minus 0.1) Hz, while the mean inverse-Compton peak frequency,(v(sup IC)(sub peak) ranges from 10(sup 21) to 10(sup 22) Hz. The distributions of v(sup S)(sub peak) and of v(sup IC)(sub peak) of BL Lacs are much broader and are shifted to higher energies than those of FSRQs; their shapes strongly depend on the selection method. The Compton dominance of blazars ranges from less than 0.2 to nearly 100, with only FSRQs reaching values larger than about 3. Its distribution is broad and depends strongly on the selection method, with gamma-ray selected blazars peaking at approximately 7 or more, and radio-selected blazars at values close to 1, thus implying that the common assumption that the blazar power budget is largely dominated by high-energy emission is a selection effect. A comparison of our multi-frequency data with theoretical predictions shows that simple homogeneous SSC models cannot explain the simultaneous SEDs of most of the gamma-ray detected blazars in all samples. The SED of the blazars that were not detected by Fermi-LAT may instead be consistent with SSC emission. Our data challenge the correlation between bolometric luminosity and v(sup S)(sub peak) predicted by the blazar sequence.
NASA Astrophysics Data System (ADS)
Chadha, R.; Bali, A.
2016-05-01
Rapid, sensitive, cost effective and reproducible stability-indicating derivative spectrophotometric methods have been developed for the estimation of dronedarone HCl employing peak-zero (P-0) and peak-peak (P-P) techniques, and their stability-indicating potential assessed in forced degraded solutions of the drug. The methods were validated with respect to linearity, accuracy, precision and robustness. Excellent linearity was observed in concentrations 2-40 μg/ml ( r 2 = 0.9986). LOD and LOQ values for the proposed methods ranged from 0.42-0.46 μg/ml and 1.21-1.27 μg/ml, respectively, and excellent recovery of the drug was obtained in the tablet samples (99.70 ± 0.84%).
Fluorescence evolution of leachates during treatment processes from two contrasting landfills.
Sun, W L; Liu, T T; Cui, F; Ni, J R
2008-10-01
Landfill leachates are composed of a complex mixture of organic matter, including a wide range of potentially fluorescent organic compounds. The fluorescence excitation-emission matrix (FEEM) of leachates during treatment processes is investigated. Particular attention is paid to the fluorescence evolution of leachates during treatment processes. Two typical types of landfill, landfill A (a direct municipal solid waste (MSW) landfill) and landfill B (disposal of bottom ashes from MSW incinerators), in a city in Southern China were selected. The results show that two characteristic and intense excitation-emission peaks located at Ex/Em = 310-330 nm/395-410 nm (peak alpha) and Ex/Em = 250-260 nm/450-460 nm (peak alpha') are observed. As the aromatic chemicals, capable of emitting fluorescence, are more recalcitrant to biodegradation than aliphatic chemicals, enhancement of the dissolved organic carbon normalized fluorescence intensities is demonstrated during treatment processes of leachate A and leachate B. This is confirmed by the variation of ultraviolet absorptivity of leachates at 254 nm. Peak alpha' and peak alpha are attributed to a mixture of xenobiotic organic compounds with low molecular weight and relatively stable aromatic fulvic-like matters with high molecular weight, respectively. Humic substances are more resistant to biodegradation than xenobiotic organic compounds, so a significant reduction in the Ialpha'/Ialpha values (fluorescence intensity ratios of peak alpha' and peak a) of leachate A was observed during treatment processes. However, no evident variation for the Ialpha/Ialpha values of leachate B was found during treatment processes owing to the low concentrations of xenobiotic organic compounds in leachate B after incineration.
NASA Astrophysics Data System (ADS)
Ramachandran, S.
An analysis of PM 2.5 mass concentrations and 0.5 μm aerosol optical depths (AODs) during the Northeast winter monsoon seasons of 1996-2000 is performed and intercompared. AODs are found to show diurnal variations over Coastal India (CI) (west coast) while they are relatively smooth over the Arabian Sea (AS) (5-20°N) and tropical Indian Ocean (TIO) (5°N-20°S). PM 2.5, PM 10 and total mass concentrations show less variations in a day over these oceanic regions. Columnar AODs are found to increase with an increase in the marine boundary layer aerosol concentrations over CI and AS while an opposite trend is seen over TIO. The yearly-mean AODs and mass concentrations are found to increase over CI and AS, over TIO the mass concentrations increased while the AODs decreased during 1996-2000. It is found from the 7-days air back trajectory analyses that at different altitudes air masses can originate from different source regions leading to changes in chemical, physical and optical characteristics of the aerosol between the surface and column. The differences in the surface and columnar measurements could also occur due to changes in the meteorological conditions, wind patterns, in addition to changes in production and subsequently the transport of aerosols. Least-squares fits to the above intercomparison resulted in intercepts of 0.24 and 0.22 over CI and AS indicating that the background AODs over these oceanic regions are higher. An examination of the daily-mean wind speeds and PM 2.5 mass concentrations yielded an index of wind dependence of 0.04 for AS and 0.07 for TIO. The background PM 2.5 mass concentrations are also found to be high at 36 and 25 μg m -3 over AS and TIO, respectively, indicating a stronger influence from the continent. Frequency distribution figures show that 28% of the PM 2.5 values over CI lie in the 60-80 μg m -3 range. Over AS the dominant mode of distribution is 40-60 μg m -3 with a peak value of 42%. Over TIO PM 2.5 values are found to peak in the lower mass bin of 0-20 μg m -3 at 33%. A latitudinal gradient is seen in the peak bin value of PM 2.5 as the ship moves away from the coast. About half the days over CI and 20% over AS and TIO, PM 2.5 values are found unhealthy indicating the influence of anthropogenic pollution and long-range transport of pollutants from the surrounding continental locations across these oceanic regimes. AODs are found to peak in the 0.2-0.4 bin at 52% over CI and 47% over AS. Over AS 32% of the AODs are found to be <0.2. More than 90% of AODs over TIO are <0.2. The feature is different when compared to three maritime locations in the Pacific where 75% or more cases have AODs <0.1. α values are found to peak in the 1.5-2 range over CI at 55% while they peak in the lower range of 1-1.5 at 49% and 26% over AS and TIO, respectively. Over the Pacific and Atlantic Oceans in more than 90% of the cases α was ⩽1.5, indicating that the amount of smaller and larger particles are higher over the Indian Ocean when compared to the Pacific and Atlantic. The spread in PM 2.5 and AOD indicates that it is a challenging task to obtain a good relation without additional inputs on the vertical distribution of aerosols as varied kinds of aerosols from different source regions contribute at different heights over these oceanic regions.
TNT equivalency of M10 propellant
NASA Technical Reports Server (NTRS)
Mcintyre, F. L.; Price, P.
1978-01-01
Peak, side-on blast overpressure and scaled, positive impulse have been measured for M10 single-perforated propellant, web size 0.018 inches, using configurations that simulate the handling of bulk material during processing and shipment. Quantities of 11.34, 22.7, 45.4, and 65.8 kg were tested in orthorhombic shipping containers and fiberboard boxes. High explosive equivalency values for each test series were obtained as a function of scaled distance by comparison to known pressure, arrival time and impulse characteristics for hemispherical TNT surface bursts. The equivalencies were found to depend significantly on scaled distance, with higher values of 150-100 percent (pressure) and 350-125 percent (positive impulse) for the extremes within the range from 1.19 to 3.57 m/cube root of kg. Equivalencies as low as 60-140 percent (pressure) and 30-75 percent (positive impulse) were obtained in the range of 7.14 to 15.8 m/cube root of kg. Within experimental error, both peak pressure and positive impulse scaled as a function of charge weight for all quantities tested in the orthorhombic configuration.
Analysis of Suspended-Sediment Dynamics in Gulf of Mexico Estuaries Using MODIS/Terra 250-m Imagery
NASA Astrophysics Data System (ADS)
McCarthy, M. J.; Otis, D. B.; Muller-Karger, F. E.; Mendez-Lazaro, P.; Chen, F. R.
2016-02-01
Suspended sediments in coastal ecosystems reduce light penetration, degrade water quality, and inhibit primary production. In this study, a 15-year Moderate Resolution Imaging Spectroradiometer (MODIS/Terra) turbidity time-series was developed for use in the estuaries of the Gulf of Mexico (GOM). Remote-sensing reflectance (Rrs) at 645 nm and 250-m resolution was validated with in-situ turbidity measurements in these estuaries: Coastal Bend Bays (TX), Galveston Bay (TX), Barataria and Terrebonne Bays (LA), Mobile Bay (AL), Tampa Bay (FL), Sarasota Bay (FL), and Charlotte Harbor (FL). Mean values of turbidity over the time-series ranged from 2.5 NTU to over 10 NTU. Turbidity patterns exhibited seasonal cycles with peak values generally found during spring months, although there is considerable variability in the timing of peak turbidity. Episodes of elevated turbidity ranged from 6 episodes in Galveston Bay to 15 in Mobile Bay. The spatial extent of elevated turbidity within estuaries, frequency and duration of turbidity events, and potential driving factors behind episodes of elevated turbidity were also examined.
Altschuler, E.L.; Dowla, F.U.
1998-11-24
The encephalolexianalyzer uses digital signal processing techniques on electroencephalograph (EEG) brain waves to determine whether or not someone is thinking about moving, e.g., tapping their fingers, or, alternatively, whether someone is actually moving, e.g., tapping their fingers, or at rest, i.e., not moving and not thinking of moving. The mu waves measured by a pair of electrodes placed over the motor cortex are signal processed to determine the power spectrum. At rest, the peak value of the power spectrum in the 8-13 Hz range is high, while when moving or thinking of moving, the peak value of the power spectrum in the 8-13 Hz range is low. This measured change in signal power spectrum is used to produce a control signal. The encephalolexianalyzer can be used to communicate either directly using Morse code, or via a cursor controlling a remote control; the encephalolexianalyzer can also be used to control other devices. The encephalolexianalyzer will be of great benefit to people with various handicaps and disabilities, and also has enormous commercial potential, as well as being an invaluable tool for studying the brain. 14 figs.
Altschuler, Eric L.; Dowla, Farid U.
1998-01-01
The encephalolexianalyzer uses digital signal processing techniques on electroencephalograph (EEG) brain waves to determine whether or not someone is thinking about moving, e.g., tapping their fingers, or, alternatively, whether someone is actually moving, e.g., tapping their fingers, or at rest, i.e., not moving and not thinking of moving. The mu waves measured by a pair of electrodes placed over the motor cortex are signal processed to determine the power spectrum. At rest, the peak value of the power spectrum in the 8-13 Hz range is high, while when moving or thinking of moving, the peak value of the power spectrum in the 8-13 Hz range is low. This measured change in signal power spectrum is used to produce a control signal. The encephalolexianalyzer can be used to communicate either directly using Morse code, or via a cursor controlling a remote control; the encephalolexianalyzer can also be used to control other devices. The encephalolexianalyzer will be of great benefit to people with various handicaps and disabilities, and also has enormous commercial potential, as well as being an invaluable tool for studying the brain.
NASA Astrophysics Data System (ADS)
Gu, Tingwei; Kong, Deren; Shang, Fei; Chen, Jing
2018-04-01
This paper describes the merits and demerits of different sensors for measuring propellant gas pressure, the applicable range of the frequently used dynamic pressure calibration methods, and the working principle of absolute quasi-static pressure calibration based on the drop-weight device. The main factors affecting the accuracy of pressure calibration are analyzed from two aspects of the force sensor and the piston area. To calculate the effective area of the piston rod and evaluate the uncertainty between the force sensor and the corresponding peak pressure in the absolute quasi-static pressure calibration process, a method for solving these problems based on the least squares principle is proposed. According to the relevant quasi-static pressure calibration experimental data, the least squares fitting model between the peak force and the peak pressure, and the effective area of the piston rod and its measurement uncertainty, are obtained. The fitting model is tested by an additional group of experiments, and the peak pressure obtained by the existing high-precision comparison calibration method is taken as the reference value. The test results show that the peak pressure obtained by the least squares fitting model is closer to the reference value than the one directly calculated by the cross-sectional area of the piston rod. When the peak pressure is higher than 150 MPa, the percentage difference is less than 0.71%, which can meet the requirements of practical application.
Howell, Rebecca M; Burgett, Eric A; Isaacs, Daniel; Price Hedrick, Samantha G; Reilly, Michael P; Rankine, Leith J; Grantham, Kevin K; Perkins, Stephanie; Klein, Eric E
2016-05-01
To measure, in the setting of typical passively scattered proton craniospinal irradiation (CSI) treatment, the secondary neutron spectra, and use these spectra to calculate dose equivalents for both internal and external neutrons delivered via a Mevion single-room compact proton system. Secondary neutron spectra were measured using extended-range Bonner spheres for whole brain, upper spine, and lower spine proton fields. The detector used can discriminate neutrons over the entire range of the energy spectrum encountered in proton therapy. To separately assess internally and externally generated neutrons, each of the fields was delivered with and without a phantom. Average neutron energy, total neutron fluence, and ambient dose equivalent [H* (10)] were calculated for each spectrum. Neutron dose equivalents as a function of depth were estimated by applying published neutron depth-dose data to in-air H* (10) values. For CSI fields, neutron spectra were similar, with a high-energy direct neutron peak, an evaporation peak, a thermal peak, and an intermediate continuum between the evaporation and thermal peaks. Neutrons in the evaporation peak made the largest contribution to dose equivalent. Internal neutrons had a very low to negligible contribution to dose equivalent compared with external neutrons, largely attributed to the measurement location being far outside the primary proton beam. Average energies ranged from 8.6 to 14.5 MeV, whereas fluences ranged from 6.91 × 10(6) to 1.04 × 10(7) n/cm(2)/Gy, and H* (10) ranged from 2.27 to 3.92 mSv/Gy. For CSI treatments delivered with a Mevion single-gantry proton therapy system, we found measured neutron dose was consistent with dose equivalents reported for CSI with other proton beamlines. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
System Mass Variation and Entropy Generation in 100k We Closed-Brayton-Cycle Space Power Systems
NASA Technical Reports Server (NTRS)
Barrett, Michael J.; Reid, Bryan M.
2004-01-01
State-of-the-art closed-Brayton-cycle (CBC) space power systems were modeled to study performance trends in a trade space characteristic of interplanetary orbiters. For working-fluid molar masses of 48.6, 39.9, and 11.9 kg/kmol, peak system pressures of 1.38 and 3.0 MPa and compressor pressure ratios ranging from 1.6 to 2.4, total system masses were estimated. System mass increased as peak operating pressure increased for all compressor pressure ratios and molar mass values examined. Minimum mass point comparison between 72 percent He at 1.38 MPa peak and 94 percent He at 3.0 MPa peak showed an increase in system mass of 14 percent. Converter flow loop entropy generation rates were calculated for 1.38 and 3.0 MPa peak pressure cases. Physical system behavior was approximated using a pedigreed NASA Glenn modeling code, Closed Cycle Engine Program (CCEP), which included realistic performance prediction for heat exchangers, radiators and turbomachinery.
System Mass Variation and Entropy Generation in 100-kWe Closed-Brayton-Cycle Space Power Systems
NASA Technical Reports Server (NTRS)
Barrett, Michael J.; Reid, Bryan M.
2004-01-01
State-of-the-art closed-Brayton-cycle (CBC) space power systems were modeled to study performance trends in a trade space characteristic of interplanetary orbiters. For working-fluid molar masses of 48.6, 39.9, and 11.9 kg/kmol, peak system pressures of 1.38 and 3.0 MPa and compressor pressure ratios ranging from 1.6 to 2.4, total system masses were estimated. System mass increased as peak operating pressure increased for all compressor pressure ratios and molar mass values examined. Minimum mass point comparison between 72 percent He at 1.38 MPa peak and 94 percent He at 3.0 MPa peak showed an increase in system mass of 14 percent. Converter flow loop entropy generation rates were calculated for 1.38 and 3.0 MPa peak pressure cases. Physical system behavior was approximated using a pedigreed NASA Glenn modeling code, Closed Cycle Engine Program (CCEP), which included realistic performance prediction for heat exchangers, radiators and turbomachinery.
The Application of Quality Identification in Honey by Photoacoustic Spectroscopy.
Tao, Wen-ting; Yuan, Ping; Guo, Wen-juan; Liu, Jian-en
2015-05-01
The photoacoustic spectrum of glucose, sucrose and honey solutions in the visible range are measured by using the single-light photoacoustic spectrometer, and are compared with the spectra from spedtrophotometry method. The spectral characteristics of the above solutions show that the spectral background intensity and spectral profile have some differences for different kinds of solutions. The spectra of the three kinds of solutions all have strong peak value at 485 and 655 nm, but the intensity ratios between the two peaks are different. Besides, there are characteristic peak at 475, 576 and 630 nm for glucose, and the sucrose has apparent characteristic peak at 632 nm, these characteristic peaks can be used for detecting whether the natural honey has been added glucose or sucrose. By comparing two kinds of spectrum of the same solution, the intensity of photoacoustic spectrum is more responsive to the wavelength, indicating photoacoustic spectrometry has a higher sensitivity in the test of material composition.
NASA Astrophysics Data System (ADS)
Lee, Sung Hyun; Sunaguchi, Naoki; Hirano, Yoshiyuki; Kano, Yosuke; Liu, Chang; Torikoshi, Masami; Ohno, Tatsuya; Nakano, Takashi; Kanai, Tatsuaki
2018-02-01
In this study, we investigate the performance of the Gunma University Heavy Ion Medical Center’s ion computed tomography (CT) system, which measures the residual range of a carbon-ion beam using a fluoroscopy screen, a charge-coupled-device camera, and a moving wedge absorber and collects CT reconstruction images from each projection angle. Each 2D image was obtained by changing the polymethyl methacrylate (PMMA) thickness, such that all images for one projection could be expressed as the depth distribution in PMMA. The residual range as a function of PMMA depth was related to the range in water through a calibration factor, which was determined by comparing the PMMA-equivalent thickness measured by the ion CT system to the water-equivalent thickness measured by a water column. Aluminium, graphite, PMMA, and five biological phantoms were placed in a sample holder, and the residual range for each was quantified simultaneously. A novel method of CT reconstruction to correct for the angular deflection of incident carbon ions in the heterogeneous region utilising the Bragg peak reduction (BPR) is also introduced in this paper, and its performance is compared with other methods present in the literature such as the decomposition and differential methods. Stopping power ratio values derived with the BPR method from carbon-ion CT images matched closely with the true water-equivalent length values obtained from the validation slab experiment.
NASA Astrophysics Data System (ADS)
Faneca, Joaquin; Perova, Tatiana S.; Tolmachev, Vladimir; Baldycheva, Anna
2018-05-01
We have theoretically and experimentally demonstrated a Fabry-Pérot (FP) resonators based on a Si-air one-dimensional photonic crystal (1D PhC) with coupled triple-cavity modes (or defects). These defects are obtained by filling selected air channels in the 1D PhC with an actively reconfigurable fluid. Simulations of the optical properties of these FP resonators were performed in the wide infrared spectral range. It is shown that by changing the refractive index, nc, of the fluid simultaneously in all three channels, a set of narrow triple resonance peaks can be obtained within wide stop-bands of different order in the infrared range. In addition, at certain values of nc, splitting of the triple resonance peaks into a doublet and a single peak with a significantly larger quality factor, Q=21200, occurs. Prototype devices based on Silicon-On-Insulator platform were fabricated and characterized by electro-optical and spectroscopic measurements. The electro-optical measurements demonstrate the possibility of refractive index manipulation of the filler in the FP channels individually or simultaneously. Spectroscopic measurements performed in the range 1540 – 1630 nm using fibre-coupling confirm the presence of triple resonance peaks in the 3rd stop-band in the absence of an electric field applied to the FP channels. At an applied voltage of 10 V to the middle channel, an increase of Q to 3720 in the single peak is registered which is the highest Q demonstrated in SOI based 1D PhC to date.
Peak velocity of elbow joint during hair combing activity for normal subject
NASA Astrophysics Data System (ADS)
Che-Nan, Hasyatun; Rambely, Azmin Sham
2018-04-01
Study of upper limb movements is very important for clinical assessment and diagnosis purposes. Thus it requires the analysis of motion. Therefore this study intend to investigate peak velocity of elbow joint during hair-combing activity. Twenty healthy subjects with three trials and age range 20 - 59 years old (n = 60) performed a complete cycle of hand reaching, forward transport, combing, back transport and returning the hand to its initial position. This activity was analyzed using Vicon motion-analysis system, which consisted of three infra-red and high speed cameras. Mean total movement times was recorded at 5.2s for the whole phases. Peak velocities during reaching and forward transport were found to be decreasing in value for the healthy subject. This obtained results provide information on kinematic analysis especially on movement times and peak velocities for clinical, assessment and diagnosis purposes.
Wong, Anders S Y; Chan, Kwok-Hung; Cheng, Vincent C C; Yuen, Kwok-Yung; Kwong, Yok-Lam; Leung, Anskar Y H
2007-03-15
Reactivation of polyoma BK virus (BKV) infection is consistently associated with hemorrhagic cystitis in persons who undergo hematopoietic stem cell transplantation (HSCT). In this study, we examined the relationship of reactivation of BKV infection with pre-HSCT serologic findings of BKV antibody. Serial urine samples (n=1118) obtained from 140 HSCT recipients were prospectively obtained, and BKV loads were quantified by quantitative polymerase chain reaction. Pre-HSCT anti-BKV immunoglobulin G (IgG) levels were determined by indirect immunofluorescence. In 68 patients, there was significant peaking (i.e., > or = 3-log increase) in the urine BKV load (median peak, 1.7x10(9) copies/mL; range, 1.1x10(4) to 3.2x10(14) copies/mL) occurring at a median time of 24.5 days (range, 7-49 days). In 72 patients, low-level BKV viruria occurred without peaking (median BKV load, 10 copies/mL; range, 9.9x10(3) to 1.2x10(10) copies/mL) at a median time of 24.5 days (range, 7-49 days). Pre-HSCT anti-BKV IgG was positively related to elevated urine BKV load during HSCT (P<.001). Binary logistic regression revealed that pre-HSCT anti-BKV IgG level was the only statistically significant factor (P=.009) to be associated with a > or = 3-log increase in the peak urine BKV load (positive and negative predictive values, 69% and 68%, respectively). Nine patients developed hemorrhagic cystitis at a median of 56 days (range, 29-160); 7 of these patients were evaluable and were found to have a > or = 3-log increase in the peak BKV load. In binary logistic regression, peaking of the urine BKV load (P=.026) and graft-versus-host disease (P=.033) were found to be statistically significant risks for hemorrhagic cystitis. The identification of the serologic status of BKV as a significant risk factor for BKV viruria suggests that it should be included as an integral part of the pre-HSCT evaluation.
Comparing CT perfusion with oxygen partial pressure in a rabbit VX2 soft-tissue tumor model.
Sun, Chang-Jin; Li, Chao; Lv, Hai-Bo; Zhao, Cong; Yu, Jin-Ming; Wang, Guang-Hui; Luo, Yun-Xiu; Li, Yan; Xiao, Mingyong; Yin, Jun; Lang, Jin-Yi
2014-01-01
The aim of this study was to evaluate the oxygen partial pressure of the rabbit model of the VX2 tumor using a 64-slice perfusion CT and to compare the results with that obtained using the oxygen microelectrode method. Perfusion CT was performed for 45 successfully constructed rabbit models of a VX2 brain tumor. The perfusion values of the brain tumor region of interest, the blood volume (BV), the time to peak (TTP) and the peak enhancement intensity (PEI) were measured. The results were compared with the partial pressure of oxygen (PO2) of that region of interest obtained using the oxygen microelectrode method. The perfusion values of the brain tumor region of interest in 45 successfully constructed rabbit models of a VX2 brain tumor ranged from 1.3-127.0 (average, 21.1 ± 26.7 ml/min/ml); BV ranged from 1.2-53.5 ml/100g (average, 22.2 ± 13.7 ml/100g); PEI ranged from 8.7-124.6 HU (average, 43.5 ± 28.7 HU); and TTP ranged from 8.2-62.3 s (average, 38.8 ± 14.8 s). The PO2 in the corresponding region ranged from 0.14-47 mmHg (average, 16 ± 14.8 mmHg). The perfusion CT positively correlated with the tumor PO2, which can be used for evaluating the tumor hypoxia in clinical practice.
Linear FBG Temperature Sensor Interrogation with Fabry-Perot ITU Multi-wavelength Reference.
Park, Hyoung-Jun; Song, Minho
2008-10-29
The equidistantly spaced multi-passbands of a Fabry-Perot ITU filter are used as an efficient multi-wavelength reference for fiber Bragg grating sensor demodulation. To compensate for the nonlinear wavelength tuning effect in the FBG sensor demodulator, a polynomial fitting algorithm was applied to the temporal peaks of the wavelength-scanned ITU filter. The fitted wavelength values are assigned to the peak locations of the FBG sensor reflections, obtaining constant accuracy, regardless of the wavelength scan range and frequency. A linearity error of about 0.18% against a reference thermocouple thermometer was obtained with the suggested method.
Temperature Dependence of the Thermal Conductivity of Single Wall Carbon Nanotubes
NASA Technical Reports Server (NTRS)
Osman, Mohamed A.; Srivastava, Deepak
2000-01-01
The thermal conductivity of several single wall carbon nanotubes (CNT) has been calculated over a temperature range of 100-500 K using molecular dynamics simulations with Tersoff-Brenner potential for C-C interactions. In all cases, starting from similar values at 100K, thermal conductivities show a peaking behavior before falling off at higher temperatures. The peak position shifts to higher temperatures for nanotubes of larger diameter, and no significant dependence on the tube chirality is observed. It is shown that this phenomenon is due to onset of Umklapp scattering, which shifts to higher temperatures for nanotubes of larger diameter.
Cardiopulmonary fitness and muscle strength in patients with osteogenesis imperfecta type I.
Takken, Tim; Terlingen, Heike C; Helders, Paul J M; Pruijs, Hans; Van der Ent, Cornelis K; Engelbert, Raoul H H
2004-12-01
To evaluate cardiopulmonary function, muscle strength, and cardiopulmonary fitness (VO 2 peak) in patients with osteogenesis imperfecta (OI). In 17 patients with OI type I (mean age 13.3 +/- 3.9 years) cardiopulmonary function was assessed at rest using spirometry, plethysmography, electrocardiography, and echocardiography. Exercise capacity was measured using a maximal exercise test on a bicycle ergometer and an expired gas analysis system. Muscle strength in shoulder abductors, hip flexors, ankle dorsal flexor, and grip strength were measured. All results were compared with reference values. Cardiopulmonary function at rest was within normal ranges, but when it was compared with normal height for age and sex, vital capacities were reduced. Mean absolute and relative VO 2 peak were respectively -1.17 (+/- 0.67) and -1.41 (+/- 1.52) standard deviations lower compared with reference values ( P < .01). Muscle strength also was significantly reduced in patients with OI, ranging from -1.24 +/- 1.40 to -2.88 +/- 2.67 standard deviations lower compared with reference values. In patients with OI type I, no pulmonary or cardiac abnormalities at rest were found. The exercise tolerance and muscle strength were significantly reduced in patients with OI, which might account for their increased levels of fatigue during activities of daily living.
Donati, Fabrizio; Myerson, Saul; Bissell, Malenka M.; Smith, Nicolas P.; Neubauer, Stefan; Monaghan, Mark J.; Nordsletten, David A.
2017-01-01
Background— Transvalvular peak pressure drops are routinely assessed noninvasively by echocardiography using the Bernoulli principle. However, the Bernoulli principle relies on several approximations that may not be appropriate, including that the majority of the pressure drop is because of the spatial acceleration of the blood flow, and the ejection jet is a single streamline (single peak velocity value). Methods and Results— We assessed the accuracy of the Bernoulli principle to estimate the peak pressure drop at the aortic valve using 3-dimensional cardiovascular magnetic resonance flow data in 32 subjects. Reference pressure drops were computed from the flow field, accounting for the principles of physics (ie, the Navier–Stokes equations). Analysis of the pressure components confirmed that the spatial acceleration of the blood jet through the valve is most significant (accounting for 99% of the total drop in stenotic subjects). However, the Bernoulli formulation demonstrated a consistent overestimation of the transvalvular pressure (average of 54%, range 5%–136%) resulting from the use of a single peak velocity value, which neglects the velocity distribution across the aortic valve plane. This assumption was a source of uncontrolled variability. Conclusions— The application of the Bernoulli formulation results in a clinically significant overestimation of peak pressure drops because of approximation of blood flow as a single streamline. A corrected formulation that accounts for the cross-sectional profile of the blood flow is proposed and adapted to both cardiovascular magnetic resonance and echocardiographic data. PMID:28093412
The crystallization of tough thermoplastic resins in the presence of carbon fibers
NASA Technical Reports Server (NTRS)
Theil, Michael H.
1988-01-01
The presence of carbon fibers increased the crystallization rates of both PEEK and PPS thermoplastic polymers. The effect was most pronounced at higher crystallization temperatures. Isothermal crystallization rates were analyzed by applying classical phenomenological nucleation theory. Unusually high values of the so-called Avrami exponent were found for neat PEEK. Isothermal crystallization of PEEK and PPS polymers produced crystalline samples having a wide variety of melting temperatures. The melting as observed by differential scanning calorimetry occurred as dual endotherms which were called primary (higher temperature) and secondary melting peaks. Each primary peak accounted for most of the crystallinity present. The secondary peaks represented the melting of crystallites formed later than those attributable to the primary endotherms. The presence of carbon fibers increased the thermal stability of both PEEK and PPS crystallites as manifested by higher temperatures for the primary melting peaks. This may be attributable to increased crystallite size, greater crystallite perfection, and/or favorable modification of the crystallite interface. Over the range studied, crystallization temperature strongly influenced the positions of the secondary peaks but not the primary peaks.
NASA Astrophysics Data System (ADS)
Peng, Wen-Ping; Lee, Yuan T.; Ting, Joseph W.; Chang, Huan-Cheng
2005-02-01
A sine wave that controls a quadrupole ion trap is generated from a low voltage source, boosted to high voltage through a transformer. Since not even the best transformers can keep a flat amplitude response with respect to frequency, knowing the accurate peak-to-peak value of the sine wave is paramount when the frequency is varied. We have developed an averaging peak-to-peak voltage detector for such measurements and demonstrated that the device is an essential tool to make possible high-precision mass determination of single charged microparticles with masses greater than 1×1011u. Tests of the detector with sine waves from a FLUKE 5720A standard source in the neighborhood of 1400Vpp and frequencies ranging from 100to700Hz showed a measurement accuracy better than 10ppm. The detector settled within 5s after each reset to 5 digits of DVM rock-steady reading, and the calibration against the same source after 3weeks of continuous use of the circuit produced a mere overall 1ppm difference.
NASA Astrophysics Data System (ADS)
Li, XueAi; Han, XiJiang; Du, YunChen; Xu, Ping
2011-01-01
Magnetic and electromagnetic properties were investigated on the composites of iron oxide and Co-B alloy, which were prepared by a modified chemical reduction method. The composites are characterized by scanning electron microscopy (SEM), energy dispersive X-ray analysis (EDXA), X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS) and vibrating sample magnetometry (VSM). The complex electromagnetic parameters (permittivity ɛr= ɛr'+j ɛr″ and permeability μr= μr'+j μr″) of paraffin mixed composite samples (paraffin:composites=1:1 in mass ratio) were measured in the frequency range 2-18 GHz by vector network analyzer. The measured real part ( ɛr') and imaginary part ( ɛr″) of the relative permittivity show two resonant peaks in the range of 2-18 GHz. The imaginary parts of relative permeability ( μr″) of all samples exhibited one broad resonant peak over the 2-8 GHz range. The μr″ of samples with higher molar ratio of Co to Fe (C and D) shows negative values within 13-18 GHz, which exhibit resonant and antiresonant permeabilities simultaneously. Calculation results indicated that the reflection loss values of the composites and paraffin wax mixtures are less than -10 dB with frequency width of about 6 GHz at the matching thickness.
Preparation of Binary and Ternary Oxides by Molten Salt Method and its Electrochemical Properties
NASA Astrophysics Data System (ADS)
Reddy, M. V.; Theng, L. Pei; Soh, Hulbert; Beichen, Z.; Jiahuan, F.; Yu, C.; Ling, A. Yen; Andreea, L. Y.; Ng, C. H. Justin; Liang, T. J. L. Galen; Ian, M. F.; An, H. V. T.; Ramanathan, K.; Kevin, C. W. J.; Daryl, T. Y. W.; Hao, T. Yi; Loh, K. P.; Chowdari, B. V. R.
2013-07-01
We report simple binary oxides namely SnO2, TiO2, CuO, MnO2, Fe2O3, Co3O4 and ternary oxides like MnCo2O4 by molten salt method at a temperature range of 280°C to 950°C in air and discuss the effect of morphology, crystal structure and electrochemical properties of binary and ternary oxides. Materials were characterized by X-Ray Diffraction (XRD), Scanning Electron Microscopy (SEM) and Brunauer-Emmett-Teller (BET) surface area methods. XRD patterns showed all MSM prepared materials exhibited characteristic lattice parameter values. BET surface area varies depending on the nature of the material, molten salt and preparation temperature and the obtained values are in the range, 1 to 160 m2/g. Electrochemical properties were studied using cyclic voltammetry (CV) and electrochemical performance studies were carried in the voltage range, 0.005-1.0V for SnO2, 1.0-2.8V for TiO2 and Fe2O3, MCo2O4 (M = Co, Mn), MnO2 and CuO were cycled in the range, 0.005-3.0V. At a current rates of 30-100 mA/g and a scan rate of 0.058 mV/sec was used for galvanostatic cycling and cyclic voltammetry. SnO2 showed that an alloying-de-alloying reaction occurs at ˜0.2 and ˜0.5 V vs. Li. TiO2 main intercalation and de-interaction reactions at ˜1.7 and ˜1.8 V vs. Li. Co3O4, MnCo2O4, and MnO2 main discharge potentials at ˜1.2, 0.9V and 0.4V, resp. and charge potentials peak ˜2.0V and 1.5V vs. Li. CuO prepared at 750°C exhibited main anodic peak at ˜2.45V and cathodic peaks at ˜0.85V and ˜1.25V. We discussed the possible reaction mechanisms and Li-storage performance values in detail.
Moody, John A.
2016-03-21
Extreme rainfall in September 2013 caused destructive floods in part of the Front Range in Boulder County, Colorado. Erosion from these floods cut roads and isolated mountain communities for several weeks, and large volumes of eroded sediment were deposited downstream, which caused further damage of property and infrastructures. Estimates of peak discharge for these floods and the associated rainfall characteristics will aid land and emergency managers in the future. Several methods (an ensemble) were used to estimate peak discharge at 21 measurement sites, and the ensemble average and standard deviation provided a final estimate of peak discharge and its uncertainty. Because of the substantial erosion and deposition of sediment, an additional estimate of peak discharge was made based on the flow resistance caused by sediment transport effects.Although the synoptic-scale rainfall was extreme (annual exceedance probability greater than 1,000 years, about 450 millimeters in 7 days) for these mountains, the resulting peak discharges were not. Ensemble average peak discharges per unit drainage area (unit peak discharge, [Qu]) for the floods were 1–2 orders of magnitude less than those for the maximum worldwide floods with similar drainage areas and had a wide range of values (0.21–16.2 cubic meters per second per square kilometer [m3 s-1 km-2]). One possible explanation for these differences was that the band of high-accumulation, high-intensity rainfall was narrow (about 50 kilometers wide), oriented nearly perpendicular to the predominant drainage pattern of the mountains, and therefore entire drainage areas were not subjected to the same range of extreme rainfall. A linear relation (coefficient of determination [R2]=0.69) between Qu and the rainfall intensity (ITc, computed for a time interval equal to the time-of-concentration for the drainage area upstream from each site), had the form: Qu=0.26(ITc-8.6), where the coefficient 0.26 can be considered to be an area-averaged peak runoff coefficient for the September 2013 rain storms in Boulder County, and the 8.6 millimeters per hour to be the rainfall intensity corresponding to a soil moisture threshold that controls the soil infiltration rate. Peak discharge estimates based on the sediment transport effects were generally less than the ensemble average and indicated that sediment transport may be a mechanism that limits velocities in these types of mountain streams such that the Froude number fluctuates about 1 suggesting that this type of floodflow can be approximated as critical flow.
Poupard, Laurent; Court-Fortune, Isabelle; Pichot, Vincent; Chouchou, Florian; Barthélémy, Jean-Claude; Roche, Frédéric
2011-12-01
Several studies have correlated the ratio of the very low frequency power spectral density of heart rate increment (%VLFI) with obstructive sleep apnoea syndrome (OSAS). However, patients with impaired heart rate variability may exhibit large variations of heart rate increment (HRI) spectral pattern and alter the screening accuracy of the method. To overcome this limitation, the present study uses the high-frequency increment (HFI) peak in the HRI spectrum, which corresponds to the respiratory influence on RR variations over the frequency range 0.2 to 0.4 Hz. We evaluated 288 consecutive patients referred for snoring, observed nocturnal breathing cessation and/or daytime sleepiness. Patients were classified as OSAS if their apnoea plus hypopnoea index (AHI) during polysomnography exceeded 15 events per hour. Synchronized electrocardiogram Holter monitoring allowed HRI analysis. Using a %VLFI threshold >2.4% for identifying the presence of OSAS, sensitivity for OSAS was 74.9%, specificity 51%, positive predictive value 54.9% and negative predictive value 71.7% (33 false negative subjects). Using threshold for %VLFI >2.4% and HFI peak position >0.4 Hz, negative predictive value increased to 78.2% while maintaining specificity at 50.6%. Among 11 subjects with %VLFI <2.4% and HFI peak >0.4 Hz, nine demonstrated moderate to severe OSAS (AHI >30). HFI represents a minimal physiological criterion for applying %VLFI by ensuring that heart rate variations are band frequency limited.
Dynamics of road traffic noise in Bhadrak city, India.
Swain, Bijay Kumar; Panda, Santosh Kumar; Goswami, Shreerup
2012-11-01
Road traffic noise assessed in 13 different squares of major intersection points in Bhadrak city during four different specified times i.e. 7-10 a.m., 11 a.m.-2 p.m., 3-6 p.m. and 7-10 p.m.. Road traffic was found to be the most important source of community noise at the studied sites. The noise levels of all the 13 squares were found to be beyond the permissible limit [70 dB (A)] during day time. Leq (equivalent noise level) values ranged from 93.4 to 100.5; 91.5 to 100.6; 95.1 to 107.3 and 97.3 to 106.3 dB during 7-10 a.m., 11 a.m.-2 p.m., 3-6 p.m. and 7-10 p.m. respectively. LNP values range from 115.7 to 127.7; 114.2 to 129.8; 118.2 to 138.2 and 120.7 to 135 dB, while TNI values range from 134.3 to 154.7; 130.7 to 157.9; 136.7 to 168.2 and 137.2 to 165 dB during 7-10 a.m., 11 a.m.-2 p.m., 3-6 p.m. and 7-10 p.m. respectively. Reprehensibly, even minimum LNP and TNI values are more than 114 and 130 dB respectively. Analysis of variance also computed for investigated squares at the peak hour i.e. 7-10 p.m. to infer the level of significance. The observed value of F (0.47) was less than the tabulated values and was not significant at both 5 and 1% levels of significance. Thus, the noise levels of different squares did not differ significantly at their peak hours. A preliminary public health survey carried out based on questionnaire method amongst 202 local inhabitants reveal the degree of annoyance due to road traffic noise.
NASA Astrophysics Data System (ADS)
Paralı, Levent; Sarı, Ali; Kılıç, Ulaş; Şahin, Özge; Pěchoušek, Jiří
2017-09-01
We report an improvement of the artificial neural network (ANN) modelling of a piezoelectric actuator vibration based on the experimental data. The controlled vibrations of an actuator were obtained by utilizing the swept-sine signal excitation. The peak value in the displacement signal response was measured by a laser displacement sensor. The piezoelectric actuator was modelled in both linear and nonlinear operating range. A consistency from 90.3 up to 98.9% of ANN modelled output values and experimental ones was reached. The obtained results clearly demonstrate exact linear relationship between the ANN model and experimental values.
Fiber optic photoelastic pressure sensor for high temperature gases
NASA Technical Reports Server (NTRS)
Wesson, Laurence N.; Redner, Alex S.; Baumbick, Robert J.
1990-01-01
A novel fiber optic pressure sensor based on the photoelastic effects has been developed for extremely high temperature gases. At temperatures varying from 25 to 650 C, the sensor experiences no change in the peak pressure of the transfer function and only a 10 percent drop in dynamic range. Refinement of the sensor has resulted in an optoelectronic interface and processor software which can calculate pressure values within 1 percent of full scale at any temperature within the full calibrated temperature range.
40 CFR 1065.365 - Nonmethane cutter penetration fractions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... hydrocarbon standard or equal to the THC analyzer's span value. For CH4 analyzers with multiple ranges... single FID for THC and CH4 determination with an NMC that is calibrated with propane, C3H8, by bypassing... hydrocarbon standard and the C2H6 concentration typical of the peak total hydrocarbon (THC) concentration...
van der Net, J; Vos, R C; Engelbert, R H H; van den Berg, M H; Helders, P J M; Takken, T
2006-09-01
In the Netherlands comparable levels of sports-participation between persons with haemophilia and healthy controls have been reported. This raises the question if children with haemophilia under the currently available prophylaxis do reach comparable levels of physical fitness and health-related quality of life (HRQoL) as their healthy peers. The aim of this study was to investigate the level of physical fitness, functional ability and quality of life and to determine the feasibility to safely test the exercise capacity of boys with severe haemophilia A. Thirteen subjects participated in this study. Physical fitness was determined using the measurement of maximal oxygen uptake (VO2peak) attained during a graded maximal exercise test to volitional exhaustion. Joint health, physical activity levels and health-related quality of life (Haemo-Qol) were also measured. Mean VO2peak was 1.86+/-0.77 L min-1 (Z-score: -0.39+/-1.61) which was not significantly different from reference values. Relative VO2peak was 47.42+/-8.29 mL min-1 kg-1 (Z-score: -0.52+/-1.43), which did not differ significantly from reference values either. One boy suffered a joint bleeding one day after the test. Haemo-Qol scores in parents and children ranged from 3.2% to 36.7% (100% reflects poor outcome). Relationship between the child or parent reports of Haemo-QoL and both absolute and relative VO2peak ranged from R=0.00 and R=0.4. Exercise testing in children with severe haemophilia A was a safe procedure. Patients with severe haemophilia A with good joint health and no limitations of activities have comparable physical fitness and physical active lifestyle with healthy peers and good HRQoL.
Song, Fanhao; Wu, Fengchang; Guo, Fei; Wang, Hao; Feng, Weiying; Zhou, Min; Deng, Yanghui; Bai, Yingchen; Xing, Baoshan; Giesy, John P
2017-12-15
In aquatic environments, pH can control environmental behaviors of fulvic acid (FA) via regulating hydrolysis of functional groups. Sub-fractions of FA, eluted using pyrophosphate buffers with initial pHs of 3.0 (FA 3 ), 5.0 (FA 5 ), 7.0 (FA 7 ), 9.0 (FA 9 ) and 13.0 (FA 13 ), were used to explore interactions between the various, operationally defined, FA fractions and protons, by use of EEM-PARAFAC analysis. Splitting of peaks (FA 3 and FA 13 ), merging of peaks (FA 7 ), disappearance of peaks (FA 9 and FA 13 ), and red/blue-shifting of peaks were observed during fluorescence titration. Fulvic-like components were identified from FA 3 -FA 13 , and protein-like components were observed in fractions FA 9 and FA 13 . There primary compounds (carboxylic-like, phenolic-like, and protein-like chromophores) in PARAFAC components were distinguished based on acid-base properties. Dissociation constants (pK a ) for fulvic-like components with proton ranged from 2.43 to 4.13 in an acidic pH and from 9.95 to 11.27 at basic pH. These results might be due to protonation of di-carboxylate and phenolic functional groups. At basic pH, pK a values of protein-like components (9.77-10.13) were similar to those of amino acids. However, at acidic pH, pK a values of protein-like components, which ranged from 3.33 to 4.22, were 1-2units greater than those of amino acids. Results presented here, will benefit understanding of environmental behaviors of FA, as well as interactions of FA with environmental contaminants. Copyright © 2017 Elsevier B.V. All rights reserved.
Friedel, M.J.
2008-01-01
A regularized joint inverse procedure is presented and used to estimate the magnitude of extreme rainfall events in ungauged coastal river basins of El Salvador: Paz, Jiboa, Grande de San Miguel, and Goascoran. Since streamflow measurements reflect temporal and spatial rainfall information, peak-flow discharge is hypothesized to represent a similarity measure suitable for regionalization. To test this hypothesis, peak-flow discharge values determined from streamflow recurrence information (10-year, 25-year, and 100-year) collected outside the study basins are used to develop regional (country-wide) regression equations. Peak-flow discharge derived from these equations together with preferred spatial parameter relations as soft prior information are used to constrain the simultaneous calibration of 20 tributary basin models. The nonlinear range of uncertainty in estimated parameter values (1 curve number and 3 recurrent rainfall amounts for each model) is determined using an inverse calibration-constrained Monte Carlo approach. Cumulative probability distributions for rainfall amounts indicate differences among basins for a given return period and an increase in magnitude and range among basins with increasing return interval. Comparison of the estimated median rainfall amounts for all return periods were reasonable but larger (3.2-26%) than rainfall estimates computed using the frequency-duration (traditional) approach and individual rain gauge data. The observed 25-year recurrence rainfall amount at La Hachadura in the Paz River basin during Hurricane Mitch (1998) is similar in value to, but outside and slightly less than, the estimated rainfall confidence limits. The similarity in joint inverse and traditionally computed rainfall events, however, suggests that the rainfall observation may likely be due to under-catch and not model bias. ?? Springer Science+Business Media B.V. 2007.
NASA Astrophysics Data System (ADS)
Khrustalev, K.
2016-12-01
Current process for the calibration of the beta-gamma detectors used for radioxenon isotope measurements for CTBT purposes is laborious and time consuming. It uses a combination of point sources and gaseous sources resulting in differences between energy and resolution calibrations. The emergence of high resolution SiPIN based electron detectors allows improvements in the calibration and analysis process to be made. Thanks to high electron resolution of SiPIN detectors ( 8-9 keV@129 keV) compared to plastic scintillators ( 35 keV@129keV) there are a lot more CE peaks (from radioxenon and radon progenies) can be resolved and used for energy and resolution calibration in the energy range of the CTBT-relevant radioxenon isotopes. The long term stability of the SiPIN energy calibration allows one to significantly reduce the time of the QC measurements needed for checking the stability of the E/R calibration. The currently used second order polynomials for the E/R calibration fitting are unphysical and shall be replaced by a linear energy calibration for NaI and SiPIN, owing to high linearity and dynamic range of the modern digital DAQ systems, and resolution calibration functions shall be modified to reflect the underlying physical processes. Alternatively, one can completely abandon the use of fitting functions and use only point-values of E/R (similar to the efficiency calibration currently used) at the energies relevant for the isotopes of interest (ROI - Regions Of Interest ). Current analysis considers the detector as a set of single channel analysers, with an established set of coefficients relating the positions of ROIs with the positions of the QC peaks. The analysis of the spectra can be made more robust using peak and background fitting in the ROIs with a single free parameter (peak area) of the potential peaks from the known isotopes and a fixed E/R calibration values set.
Sarig Bahat, Hilla; Chen, Xiaoqi; Reznik, David; Kodesh, Einat; Treleaven, Julia
2015-04-01
Chronic neck pain has been consistently shown to be associated with impaired kinematic control including reduced range, velocity and smoothness of cervical motion, that seem relevant to daily function as in quick neck motion in response to surrounding stimuli. The objectives of this study were: to compare interactive cervical kinematics in patients with neck pain and controls; to explore the new measures of cervical motion accuracy; and to find the sensitivity, specificity, and optimal cutoff values for defining impaired kinematics in those with neck pain. In this cross-section study, 33 patients with chronic neck pain and 22 asymptomatic controls were assessed for their cervical kinematic control using interactive virtual reality hardware and customized software utilizing a head mounted display with built-in head tracking. Outcome measures included peak and mean velocity, smoothness (represented by number of velocity peaks (NVP)), symmetry (represented by time to peak velocity percentage (TTPP)), and accuracy of cervical motion. Results demonstrated significant and strong effect-size differences in peak and mean velocities, NVP and TTPP in all directions excluding TTPP in left rotation, and good effect-size group differences in 5/8 accuracy measures. Regression results emphasized the high clinical value of neck motion velocity, with very high sensitivity and specificity (85%-100%), followed by motion smoothness, symmetry and accuracy. These finding suggest cervical kinematics should be evaluated clinically, and screened by the provided cut off values for identification of relevant impairments in those with neck pain. Such identification of presence or absence of kinematic impairments may direct treatment strategies and additional evaluation when needed. Copyright © 2014 Elsevier Ltd. All rights reserved.
Nagy, Jennifer; Winslow, Amy; Brown, Jessica M; Adams, Lisa; O'Brien, Kathleen; Boninger, Michael; Nemunaitis, Gregory
2012-01-01
To assess the peak force during wheelchair propulsion of individuals with spinal cord injury propelling over obstacles from the Wheelchair Skills Test. Twenty-three individuals with spinal cord injury (SCI) who are full-time manual wheelchair users were included in this prospective study. A SmartWheel (Three Rivers Holdings, LLC) was used to analyze each push while subjects negotiated standardized obstacles used in the Wheelchair Skills Test, including tile, carpet, soft surface, 5° and 10° ramps, 2 cm, 5 cm, and 15 cm curbs. When the peak forces of the advanced skills were compared to level 10 m tile/10 m carpet, there was a statistically significant increase in all peak forces (P value ranged from .0001 to .0268). It is well documented that a large number of individuals with SCI develop upper limb pain. One of the recommendations to preserve the upper limb is to minimize force during repetitive tasks. Advanced wheelchair skills require an increase in force to accomplish. The increase in forces ranged from 18% to 130% over that required for level 10 m tile/10 m carpet.
Infrared spectrum analysis of the dissociated states of simple amino acids.
Sebben, Damien; Pendleton, Phillip
2014-11-11
In this work, we present detailed analyses of the dissociation of dilute aqueous solutions of glycine and of lysine over the range 1
Inhibition of coronary blood flow by a vascular waterfall mechanism.
Downey, J M; Kirk, E S
1975-06-01
The mechanism whereby systole inhibits coronary blood flow was examined. A branch of the left coronary artery was maximally dilated with an adenosine infusion, and the pressure-flow relationship was obtained for beating and arrested states. The pressure-flow curve for the arrested state was shifted toward higher pressures and in the range of pressures above peak ventricular pressure was linear and parallel to that for the arrested state. Below this range the curve for the beating state converged toward that for the arrested state and was convex to the pressure axis. These results were compared with a model of the coronary vasculature that consisted of numerous parallel channels, each responding to local intramyocardial pressure by forming vascular waterfalls. When intramyocardial pressure in the model was assigned values from zero at the epicardium to peak ventricular pressure at the endocardium, pressure-flow curves similar to the experimental ones resulted. Thus, we conclude that systole inhibits coronary perfusion by the formation of vascular waterfalls and that the intramyocardial pressures responsible for this inhibition do not significantly exceed peak ventricular pressure.
Epp, V; Gün, O; Deiseroth, H-J; Wilkening, M
2013-05-21
Lithium-rich argyrodites belong to a relatively new group of fast ion conducting solids. They might serve as powerful electrolytes in all-solid-state lithium-ion batteries being, from a medium-term point of view, the key technology when safe energy storage systems have to be developed. Spin-lattice relaxation (SLR) nuclear magnetic resonance (NMR) measurements carried out in the rotating frame of reference turned out to be the method of choice to study Li dynamics in argyrodites. When plotted as a function of the inverse temperature, the SLR rates log10(R1ρ) reveal an asymmetric diffusion-induced rate peak. The rate peak contains information on the Li jump rate, the activation energy of the hopping process as well as correlation effects. In particular, considering the high-temperature flank of the SLR NMR rate peak recorded in the rotating frame of reference, an activation energy of approximately 0.49 eV is found. This value represents long-range lithium jump diffusion in crystalline Li7PSe6. As an example, at 325 K the Li jump rate determined from SLR NMR is in the order of 1.4 × 10(5) s(-1). The pronounced asymmetry of the rate peak R1ρ(1/T) points to correlated Li motion. It is comparable to that which is typically found for structurally disordered materials showing a broad range of correlation times.
NASA Technical Reports Server (NTRS)
Niedra, Janis M.
1999-01-01
100 kHz core loss and magnetization properties of sample transverse magnetically annealed, cobalt-based amorphous and iron-based nanocrystalline tape wound magnetic cores are presented over the temperature range of -150 to 150 C, at selected values of B(sub peak). For B-fields not close to saturation, the core loss is not sensitive to temperature in this range and is as low as seen in the best MnZn power ferrites at their optimum temperatures. Frequency resolved characteristics are given over the range of 50 kHz to 1 MHz, at B(sub peak) = 0.1 T and 50 C only. A linear permeability model is used to interpret and present the magnetization characteristics and several figures of merit applicable to inductor materials arc reviewed. This linear modeling shows that, due to their high permeabilities, these cores must he gapped in order to make up high Q or high current inductors. However, they should serve well, as is, for high frequency, anti ratcheting transformer applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dieter Leckel
2008-01-15
The effect of the pore structure on the hydroprocessing of heavy distillate oils derived from low-temperature coal gasification residues was studied using four NiW catalysts with different pore size distributions. The hydroprocessing was conducted at a pressure of 17.5 MPa, a temperature range of 370-410{sup o}C, and a 0.50 h{sup -1} space velocity. The degree of hydrodeoxygenation (HDO) in terms of phenolics removal was influenced by the catalyst pore structure, with the most preferable peak pore diameter for HDO ranging between 6.8 and 16 nm. The catalyst with the highest volume of pores in the 3.5-6 nm range showed themore » lowest HDO activity. The apparent activation energies for the HDO reaction varied between 59 and 87 kJ/mol, whereby the lowest values are obtained for the catalysts with a peak pore diameter of 11 and 16 nm. 30 refs., 5 figs., 6 tabs.« less
Schönig, Jette C; Mischke, Reinhard H
2016-07-01
OBJECTIVE To determine a treatment protocol for SC administration of dalteparin to cats on the basis of currently available detailed pharmacokinetic data and to assess the effect of SC administration of dalteparin to cats on coagulation variables such as activated partial thromboplastin time (aPTT), thrombin time, and results for thromboelastometry, compared with effects on anti-activated coagulation factor X (anti-Xa) activity. ANIMALS 6 healthy domestic shorthair cats. PROCEDURES Cats received 14 injections of dalteparin (75 anti-Xa U/kg, SC) at 6-hour intervals. Blood samples were collected before and 2 hours after the first and second injections on days 1, 2, and 4. Anti-Xa activity was measured by use of a chromogenic substrate assay, aPTT and thrombin time were measured by use of an automated coagulometer, and viscoelastic measurements were obtained with thromboelastrometry. RESULTS 2 hours after the second injection, the target peak anti-Xa activity range of 0.5 to 1.0 U/mL was achieved in all cats, whereas median trough values remained below this range. Peak anti-Xa activity had only minimal effects on coagulation variables; the maximum median ratio for aPTT (in relationship to the value before the first dalteparin injection) was 1.23. CONCLUSIONS AND CLINICAL RELEVANCE Results of this study indicated that this treatment protocol resulted in reproducible anti-Xa activity in cats that was mostly within the targeted peak range of anti-Xa activity recommended for humans. Treatment in accordance with this protocol may not require routine coagulation monitoring of cats, but this must be confirmed in feline patients.
Instrumental lahar monitoring at Merapi Volcano, Central Java, Indonesia
Lavigne, Franck; Thouret, J.-C.; Voight, B.; Young, K.; LaHusen, R.; Marso, J.; Suwa, H.; Sumaryono, A.; Sayudi, D.S.; Dejean, M.
2000-01-01
More than 50 volcanic debris flows or lahars were generated around Mt Merapi during the first rainy season following the nuees ardentes of 22 November 1994. The rainfalls that triggered the lahars were analyzed, using such instruments as weather radar and telemetered rain gauges. Lahar dynamics were also monitored, using new non-contact detection instrumentation installed on the slopes of the volcano. These devices include real-time seismic amplitude measurement (RSAM), seismic spectral amplitude measurement (SSAM) and acoustic flow monitoring (AFM) systems. Calibration of the various systems was accomplished by field measurements of flow velocities and discharge, contemporaneously with instrumental monitoring. The 1994–1995 lahars were relatively short events, their duration in the Boyong river commonly ranging between 30 min and 1 h 30 min. The great majority (90%) of the lahars was recognized at Kaliurang village between 13:00 and 17:30 h, due to the predominance of afternoon rainfalls. The observed mean velocity of lahar fronts ranged between 1.1 and 3.4 m/s, whereas the peak velocity of the flows varied from 11 to 15 m/s, under the Gardu Pandang viewpoint location at Kaliurang, to 8–10 m/s at a section 500 m downstream from this site. River slopes vary from 28 to 22 m/km at the two sites. Peak discharges recorded in various events ranged from 33 to 360 m3/s, with the maximum value of peak discharge 360 m3/s, on 20 May 1995. To improve the lahar warning system along Boyong river, some instrumental thresholds were proposed: large and potentially hazardous lahars may be detected by RSAM units exceeding 400, SSAM units exceeding 80 on the highest frequency band, or AFM values greater than 1500 mV on the low-gain, broad-band setting.
Is liver SUV stable over time in ¹⁸F-FDG PET imaging?
Laffon, Eric; Adhoute, Xavier; de Clermont, Henri; Marthan, Roger
2011-12-01
This work investigated whether (18)F-FDG PET standardized uptake value (SUV) is stable over time in the normal human liver. The SUV-versus-time curve, SUV(t), of (18)F-FDG in the normal human liver was derived from a kinetic model analysis. This derivation involved mean values of (18)F-FDG liver metabolism that were obtained from a patient series (n = 11), and a noninvasive population-based input function was used in each individual. Mean values (±95% reliability limits) of the (18)F-FDG uptake and release rate constant and of the fraction of free tracer in blood and interstitial volume were as follows: K = 0.0119 mL·min(-1)·mL(-1) (±0.0012), k(R) = 0.0065·min(-1) (±0.0009), and F = 0.21 mL·mL(-1) (±0.11), respectively. SUV(t) (corrected for (18)F physical decay) was derived from these mean values, showing that it smoothly peaks at 75-80 min on average after injection and that it is within 5% of the peak value between 50 and 110 min after injection. In the normal human liver, decay-corrected SUV(t) remains nearly constant (with a reasonable ±2.5% relative measurement uncertainty) if the time delay between tracer injection and PET acquisition is in the range of 50-110 min. In current clinical practice, the findings suggest that SUV of the normal liver can be used for comparison with SUV of suspected malignant lesions, if comparison is made within this time range.
Effect of altitude on spirometric parameters and the performance of peak flow meters.
Pollard, A. J.; Mason, N. P.; Barry, P. W.; Pollard, R. C.; Collier, D. J.; Fraser, R. S.; Miller, M. R.; Milledge, J. S.
1996-01-01
BACKGROUND: Portable peak flow meters are used in clinical practice for measurement of peak expiratory flow (PEF) at many different altitudes throughout the world. Some PEF meters are affected by gas density. This study was undertaken to establish which type of meter is best for use above sea level and to determine changes in spirometric measurements at altitude. METHODS: The variable orifice mini-Wright peak flow meter was compared with the fixed orifice Micro Medical Microplus turbine microspirometer at sea level and at Everest Base Camp (5300 m). Fifty one members of the 1994 British Mount Everest Medical Expedition were studied (age range, 19-55). RESULTS: Mean forced vital capacity (FVC) fell by 5% and PEF rose by 25.5%. However, PEF recorded with the mini-Wright peak flow meter underestimated PEF by 31%, giving readings 6.6% below sea level values. FVC was lowest in the mornings and did not improve significantly with acclimatisation. Lower PEF values were observed on morning readings and were associated with higher acute mountain sickness scores, although the latter may reflect decreased effort in those with acute mountain sickness. There was no change in forced expiratory volume in one second (FEV1) at altitude when measured with the turbine microspirometer. CONCLUSIONS: The cause of the fall in FVC at 5300 m is unknown but may be attributed to changes in lung blood volume, interstitial lung oedema, or early airways closure. Variable orifice peak flow meters grossly underestimate PEF at altitude and fixed orifice devices are therefore preferable where accurate PEF measurements are required above sea level. PMID:8711651
Pondel, Joanna; Krajewski, Piotr; Królikowska, Natalia; Tobiasz, Aleksandra; Augustyniak-Bartosik, Hanna; Hurkacz, Magdalena
2017-04-21
Therapeutic Drug Monitoring is a recognized method of personalizing treatment, having particular application in patients with chronic kidney disease who have frequent infections, requiring administration of vancomycin. International guidelines indicate the need to adjust the dose of the drug to the state of renal function. The recommended therapeutic ranges of minimum and maximum levels should be achieved in order to increase the effectiveness and safety of treatment. The aim of this study was to evaluate the usefulness of measuring the concentration of vancomycin in patients with chronic kidney disease due to bacterial infection. The study included 96 adult patients with chronic kidney disease of varying severity treated with vancomycin Patients were divided into 3 groups: treated by haemodialysis (hd), after renal transplantations (ktx), do not require renal replacement therapy (nef). In subjects were examined the minimum and maximum concentrations of vancomycin in steady-state and were compared with recommended therapeutic ranges. Statistically significant decrease of inflammatory markers was observed only in patients treated with dialysis. In the other groups not significant changes in values of inflammatory parameters were confirmed. Trough concentrations of vancomycin marked in patients were consistent with the recommendation of EUCAST, but exceeded the value recommended by the manufacturers of the drug. Considering absolute values of the minimum concentrations, only about 50% of patients achieved the therapeutic range (58% for recommendation EUCAST and 36% for the manufacturer's instructions). Peak concentration values indicated in dialyzed patients were below the prescribed range of 20-50 mg/l and averaged 17.7 mg / l. In the other subgroups they were correct. The rating of the absolute values of the peak concentrations of vancomycin also showed that only 46% (64% in the ktx, 30% - hd and 53% - nef) was within the recommended range, while 50% were classified as concentrations of sub-therapeutic (36% in the ktx, 42% of the nef group and 65% in hd). Vancomycin concentrations measured in patients with chronic kidney disease, both minimum and maximum, were not fully comply with the recommended therapeutic ranges, despite the use of doses determined based on a calculation of glomerular filtration rate. This points to the need for particularly careful monitoring of therapy and analysis of antibiotic concentrations to improve the effectiveness and reduce the incidence of undesirable consequences of treatment.
Temporal evolution modeling of hydraulic and water quality performance of permeable pavements
NASA Astrophysics Data System (ADS)
Huang, Jian; He, Jianxun; Valeo, Caterina; Chu, Angus
2016-02-01
A mathematical model for predicting hydraulic and water quality performance in both the short- and long-term is proposed based on field measurements for three types of permeable pavements: porous asphalt (PA), porous concrete (PC), and permeable inter-locking concrete pavers (PICP). The model was applied to three field-scale test sites in Calgary, Alberta, Canada. The model performance was assessed in terms of hydraulic parameters including time to peak, peak flow and water balance and a water quality variable (the removal rate of total suspended solids). A total of 20 simulated storm events were used for model calibration and verification processes. The proposed model can simulate the outflow hydrographs with a coefficient of determination (R2) ranging from 0.762 to 0.907, and normalized root-mean-square deviation (NRMSD) ranging from 13.78% to 17.83%. Comparison of the time to peak flow, peak flow, runoff volume and TSS removal rates between the measured and modeled values in model verification phase had a maximum difference of 11%. The results demonstrate that the proposed model is capable of capturing the temporal dynamics of the pavement performance. Therefore, the model has great potential as a practical modeling tool for permeable pavement design and performance assessment.
Revisiting Tectonic Corrections Applied to Pleistocene Sea-Level Highstands
NASA Astrophysics Data System (ADS)
Creveling, J. R.; Mitrovica, J. X.; Hay, C.; Austermann, J.; Kopp, R. E.
2015-12-01
The robustness of stratigraphic- and geomorphic-based inferences of Quaternary peak interglacial sea levels — and equivalent minimum continental ice volumes — depends on the accuracy with which highstand markers can be corrected for vertical tectonic displacement. For sites that preserve a Marine Isotope Stage (MIS) 5e sea-level highstand marker, the customary method for estimating tectonic uplift/subsidence rate computes the difference between the local elevation of the highstand marker and a reference eustatic (i.e., global mean) MIS 5e sea-level height, typically assumed to be +6 m, and then divides this height difference by the age of the highstand marker. This rate is then applied to correct the elevation of other observed sea-level markers at that site for tectonic displacement. Subtracting a reference eustatic value from a local MIS 5e highstand marker elevation introduces two potentially significant errors. First, the commonly adopted peak eustatic MIS 5e sea-level value (i.e., +6 m) is likely too low; recent studies concluded that MIS 5e peak eustatic sea level was ~6-9 m. Second, local peak MIS 5e sea level was not globally uniform, but instead characterized by significant departures from eustasy due to glacial isostatic adjustment (GIA) in response to successive glacial-interglacial cycles and excess polar ice-sheet melt relative to present day. We present numerical models of GIA that incorporate both of these effects in order to quantify the plausible range in error of previous tectonic corrections. We demonstrate that, even far from melting ice sheets, local peak MIS 5e sea level may have departed from eustasy by 2-4 m, or more. Thus, adopting an assumed reference eustatic value to estimate tectonic displacement, rather than a site-specific GIA signal, can introduce significant error in estimates of peak eustatic sea level (and minimum ice volumes) during Quaternary highstands (e.g., MIS 11, MIS 5c and MIS 5a).
Zhang, Di; Cagnon, Chris H; Villablanca, J Pablo; McCollough, Cynthia H; Cody, Dianna D; Zankl, Maria; Demarco, John J; McNitt-Gray, Michael F
2013-09-01
CT neuroperfusion examinations are capable of delivering high radiation dose to the skin or lens of the eyes of a patient and can possibly cause deterministic radiation injury. The purpose of this study is to: (a) estimate peak skin dose and eye lens dose from CT neuroperfusion examinations based on several voxelized adult patient models of different head size and (b) investigate how well those doses can be approximated by some commonly used CT dose metrics or tools, such as CTDIvol, American Association of Physicists in Medicine (AAPM) Report No. 111 style peak dose measurements, and the ImPACT organ dose calculator spreadsheet. Monte Carlo simulation methods were used to estimate peak skin and eye lens dose on voxelized patient models, including GSF's Irene, Frank, Donna, and Golem, on four scanners from the major manufacturers at the widest collimation under all available tube potentials. Doses were reported on a per 100 mAs basis. CTDIvol measurements for a 16 cm CTDI phantom, AAPM Report No. 111 style peak dose measurements, and ImPACT calculations were performed for available scanners at all tube potentials. These were then compared with results from Monte Carlo simulations. The dose variations across the different voxelized patient models were small. Dependent on the tube potential and scanner and patient model, CTDIvol values overestimated peak skin dose by 26%-65%, and overestimated eye lens dose by 33%-106%, when compared to Monte Carlo simulations. AAPM Report No. 111 style measurements were much closer to peak skin estimates ranging from a 14% underestimate to a 33% overestimate, and with eye lens dose estimates ranging from a 9% underestimate to a 66% overestimate. The ImPACT spreadsheet overestimated eye lens dose by 2%-82% relative to voxelized model simulations. CTDIvol consistently overestimates dose to eye lens and skin. The ImPACT tool also overestimated dose to eye lenses. As such they are still useful as a conservative predictor of dose for CT neuroperfusion studies. AAPM Report No. 111 style measurements are a better predictor of both peak skin and eye lens dose than CTDIvol and ImPACT for the patient models used in this study. It should be remembered that both the AAPM Report No. 111 peak dose metric and CTDIvol dose metric are dose indices and were not intended to represent actual organ doses.
The role of discharge variability in the formation and preservation of alluvial sediment bodies
NASA Astrophysics Data System (ADS)
Fielding, Christopher R.; Alexander, Jan; Allen, Jonathan P.
2018-03-01
Extant, planform-based facies models for alluvial deposits are not fully fit for purpose, because they over-emphasise plan form whereas there is little in the alluvial rock record that is distinctive of any particular planform, and because the planform of individual rivers vary in both time and space. Accordingly, existing facies models have limited predictive capability. In this paper, we explore the role of inter-annual peak discharge variability as a possible control on the character of the preserved alluvial record. Data from a suite of modern rivers, for which long-term gauging records are available, and for which there are published descriptions of subsurface sedimentary architecture, are analysed. The selected rivers are categorized according to their variance in peak discharge or the coefficient of variation (CVQp = standard deviation of the annual peak flood discharge over the mean annual peak flood discharge). This parameter ranges over the rivers studied between 0.18 and 1.22, allowing classification of rivers as having very low (< 0.20), low (0.20-0.40), moderate (0.40-0.60), high (0.60-0.90), or very high (> 0.90) annual peak discharge variance. Deposits of rivers with very low and low peak discharge variability are dominated by cross-bedding on various scales and preserve macroform bedding structure, allowing the interpretation of bar construction processes. Rivers with moderate values preserve mostly cross-bedding, but records of macroform processes are in places muted and considerably modified by reworking. Rivers with high and very high values of annual peak discharge variability show a wide range of bedding structures commonly including critical and supercritical flow structures, abundant in situ trees and transported large, woody debris, and their deposits contain pedogenically modified mud partings and generally lack macroform structure. Such a facies assemblage is distinctively different from the conventional fluvial style recorded in published facies models but is widely developed both in modern and ancient alluvial deposits. This high-peak-variance style is also distinctive of rivers that are undergoing contraction in discharge over time because of the gradual annexation of the channel belt by the establishment of woody vegetation. We propose that discharge variability, both inter-annual peak variation and "flashiness" may be a more reliable basis for classifying the alluvial rock record than planform, and we provide some examples of three classes of alluvial sediment bodies (representing low, intermediate, and high/very high discharge variability) from the rock record that illustrate this point.
Zhang, Di; Cagnon, Chris H.; Villablanca, J. Pablo; McCollough, Cynthia H.; Cody, Dianna D.; Zankl, Maria; Demarco, John J.; McNitt-Gray, Michael F.
2013-01-01
Purpose: CT neuroperfusion examinations are capable of delivering high radiation dose to the skin or lens of the eyes of a patient and can possibly cause deterministic radiation injury. The purpose of this study is to: (a) estimate peak skin dose and eye lens dose from CT neuroperfusion examinations based on several voxelized adult patient models of different head size and (b) investigate how well those doses can be approximated by some commonly used CT dose metrics or tools, such as CTDIvol, American Association of Physicists in Medicine (AAPM) Report No. 111 style peak dose measurements, and the ImPACT organ dose calculator spreadsheet. Methods: Monte Carlo simulation methods were used to estimate peak skin and eye lens dose on voxelized patient models, including GSF's Irene, Frank, Donna, and Golem, on four scanners from the major manufacturers at the widest collimation under all available tube potentials. Doses were reported on a per 100 mAs basis. CTDIvol measurements for a 16 cm CTDI phantom, AAPM Report No. 111 style peak dose measurements, and ImPACT calculations were performed for available scanners at all tube potentials. These were then compared with results from Monte Carlo simulations. Results: The dose variations across the different voxelized patient models were small. Dependent on the tube potential and scanner and patient model, CTDIvol values overestimated peak skin dose by 26%–65%, and overestimated eye lens dose by 33%–106%, when compared to Monte Carlo simulations. AAPM Report No. 111 style measurements were much closer to peak skin estimates ranging from a 14% underestimate to a 33% overestimate, and with eye lens dose estimates ranging from a 9% underestimate to a 66% overestimate. The ImPACT spreadsheet overestimated eye lens dose by 2%–82% relative to voxelized model simulations. Conclusions: CTDIvol consistently overestimates dose to eye lens and skin. The ImPACT tool also overestimated dose to eye lenses. As such they are still useful as a conservative predictor of dose for CT neuroperfusion studies. AAPM Report No. 111 style measurements are a better predictor of both peak skin and eye lens dose than CTDIvol and ImPACT for the patient models used in this study. It should be remembered that both the AAPM Report No. 111 peak dose metric and CTDIvol dose metric are dose indices and were not intended to represent actual organ doses. PMID:24007152
Harnessing Solar Energy Using Photosynthetic and Organic Pigments
NASA Astrophysics Data System (ADS)
Fitzsimons, Toby Ryan
Fossil fuels are a finite energy resource that must be supplemented or replaced by more stable forms of electrical energy. Solar technology research strives to supplement and provide eventual replacement for fossil fuel technology. This experiment focused on the use of natural pigments as photo-sensitizers in the current generation of solar cells called dye sensitized solar cells (DSSCs). Pigments from purified chlorophyll a, chlorophyll b, chlorophyll a/b, crude spinach (Spinacia oleracea) extract, phycocyanin, and chlorophyllin were used to construct DSSCs and evaluated, along with a control containing no pigment, for solar energy conversion. The anode of the solar cells consisted of titanium dioxide (TiO2) plates soaked in pigment solutions for twenty-four hours. The plates were assembled, along with an electrolyte sandwiched between cells, and a platinum-coated counter plate that functioned as the cathode. A gasket seal was placed between the plates and held together with rubber bands. The DSSCs were each tested for a maximum power (Pmax) point and a resistor was selected that corresponded to the resistance at that point. The cells were randomly placed into a power block assembly located in an environmental chamber with lighting that provided an average of 27,590 lumens at the surface of DSSCs. With appropriate resistors in place, the cells were subjected to twelve-hour days and twelve-hour nights for ten days, and measurements were recorded every ten minutes. Data were collected to obtain values for voltage in millivolts (mV), current in microamps (microA), and power in microwatts (microW), as well as beginning and ending efficiencies in converting light to usable energy. Voltages were substantially higher during the day than at night for all pigments, except for the control, indicating that the pigments functioned as DSSCs. Hence, only daytime values were used for data analysis. Voltage during the ten-day experiment ranged from 3.99 to 274 mV; current ranged from 0.0180 to 41.9 microA, and power ranged from 0.00 to 11.3 microW. Chlorophyllin had the highest peak and least voltage (274 and 161 mV), highest peak and least current (41.9 and 21.8 microA), and highest peak and least power (11.3 and 4.84 microW). The ranking of the pigments for peak voltage was: Chlorophyllin = Crude Extract ≥ Chlorophyll a = Chlorophyll a/b ≥ Phycocyanin = Chlorophyll b > Control. The ranking for least voltage was: Chlorophyllin > Phycocyanin ≥ Chlorophyll a/b ≥ Crude Extract ≥ Chlorophyll b ≥ Chlorophyll a ≥ Control. Ranking for peak and least values were similar for current and power. Solar energy conversion (efficiency in converting light energy to usable energy in watts per square meter) for all treatments ranged from 0.000595 to 0.0217% at the beginning of the experiment, and was highest in cells constructed with chlorophyllin. Based on rankings from peak and ending voltage values, as well as other measurements, it was concluded that DSSCs constructed with chlorophyllin performed the best and lasted the longest as photo-sensitizers, compared to other pigments used in this investigation. The DSSCs constructed with crude extract performed almost as well as those constructed with chlorophyllin at the beginning of the experiment, but degradation of this naturally-made pigment may have prevented these cells from sustaining solar energy conversion for more than a few days. Other pigments demonstrated conversion values higher than those of control DSSCs which contained no pigments. The results from this project provide evidence that DSSCs can produce useable energy. More research is needed to enhance and prolong the efficiency of DSSCs in solar energy conversion.
NASA Astrophysics Data System (ADS)
Murphy, P. J.; LaGrange, M. S.
1998-11-01
Previous work on gold chloride and hydroxide speciation in fluids has shown differences in opinion as to the relative importance of gold (I) and gold (III) species, as well as for the Raman peak assignments for the various species. In addition, previous experimental work has not been consistent with theoretical predictions either of the number or of the frequencies of the peaks in the Raman spectrum. In order to re-evaluate the effect of pH on Raman spectra and speciation, solutions containing gold (III) chloride were analysed by Raman spectroscopy at ambient temperature and pressure, over a range of pH from 1 to 11. Total gold concentrations were from 0.001 to 0.02 M, with total chloride concentrations of 0.004-0.5 M. The spectra obtained are consistent with the hydrolysis sequence of square-planar Au(III) complex ions [AuCl x(OH) 4-x] -, where x = 0-4. The Au-Cl stretching peaks obtained were 348/325 Rcm -1 for [AuCl 4] -, 348/335/325 Rcm -1 for [AuCl 3(OH)] -, 337/355 Rcm -1 for [AuCl 2(OH) 2] -, and 355 Rcm -1 for [AuCl(OH) 3] -. [Au(OH) 4] - probably occurred, alongside [AuCl(OH) 3] - at pH values above 11. A dark purplish-grey precipitate (Au(I)OH) formed at high pH values. No evidence for Au(I) species was found. The spectra are more consistent with theory than previous data and show the predicted number of peaks for Au-Cl and Au-OH stretches for each species. However, the peak frequencies do not fit precisely with the predictions of Tossell (1996), particularly for Au-OH stretches. Hydrolysis of the simple chloride species occurs at lower pH values than found previously, and both gold and chloride concentration were found to affect the pH ranges of stability for the various chloro-hydroxy species. Decreasing gold concentration resulted in hydrolysis occurring at lower pH values. This is especially important in the absence of excess chloride (ΣCl = 4ΣAu). Substantial hydrolysis occurred below pH = 4 for 0.02 M Au /0.08 M Cl -, and below pH = 2 for 0.001 M Au / 0.004 M Cl -. Addition of excess chloride (as NaCl) increases the pH of hydrolysis at a given gold concentration.
NASA Astrophysics Data System (ADS)
Padilla, D.; Steiner, J. C.
2005-12-01
Fourier Transform Infrared (FTIR) examination of the combustion products of selected forest materials using a meeker burner flame at temperatures up to 500 degrees Celsius produces a cluster of broad distinct peaks throughout the 400 to 4000 cm-1 wavenumber interval. Distinct bands bracketed by wavenumbers 400-700, 1500-1700, 2200-2400 and 3300-3600 cm-1 show variable intensity with an average difference between the least absorbing and most strongly absorbing species of approximately fifty percent. Given that spectral band differences of ten percent are within the range of modern satellite spectrometers, these band differences are of potential value for discriminating between fires that are impacting a range of vegetation types. Corresponding scanning electron microscope and energy dispersive micro-chemical (SEM/ED) analysis establishes that the evolved soot particles exhibit a characteristic rounded morphology, are carbon rich and host a wide range of adsorbed elements, including calcium, aluminum, potassium, silicon, sulfur and trace nitrogen. Combustion experiments involving leaves and branches as a subset of the biomass experiments at 200-500 degrees Celsius yield a similar broad background, but with peak shifts for maxima residing at less than 1700 cm-1. Additional peaks appear in the ranges 1438-1444, 875 and 713 cm-1. These peak are of potential use for discriminating between hot and smoldering fires, and between soot and smoke yields from green woods and whole-wood or lumber. The spectral shifts noted for low temperature smoldering conditions are in the vicinity of those cited for green vegetation and may not be resolved by present satellite platforms. Nevertheless, the experimental peak data set is of potential use for discriminating between a conflagration or accentuated fire and one characterized by smoldering at low temperature. SEM/ED analysis of the combusted leaf, branch, bark and various crown assemblages yields comparable morphological and geochemical signatures although potassium and light elements are slightly concentrated in effluent from the leafy matrix.
Linear FBG Temperature Sensor Interrogation with Fabry-Perot ITU Multi-wavelength Reference
Park, Hyoung-Jun; Song, Minho
2008-01-01
The equidistantly spaced multi-passbands of a Fabry-Perot ITU filter are used as an efficient multi-wavelength reference for fiber Bragg grating sensor demodulation. To compensate for the nonlinear wavelength tuning effect in the FBG sensor demodulator, a polynomial fitting algorithm was applied to the temporal peaks of the wavelength-scanned ITU filter. The fitted wavelength values are assigned to the peak locations of the FBG sensor reflections, obtaining constant accuracy, regardless of the wavelength scan range and frequency. A linearity error of about 0.18% against a reference thermocouple thermometer was obtained with the suggested method. PMID:27873898
Ontogeny of vestibular compound action potentials in the domestic chicken
NASA Technical Reports Server (NTRS)
Jones, S. M.; Jones, T. A.
2000-01-01
Compound action potentials of the vestibular nerve were measured from the surface of the scalp in 148 chickens (Gallus domesticus). Ages ranged from incubation day 18 (E18) to 22 days posthatch (P22). Responses were elicited using linear acceleration cranial pulses. Response thresholds decreased at an average rate of -0.45 dB/day. The decrease was best fit by an exponential model with half-maturity time constant of 5.1 days and asymptote of approximately -25.9 dB re:1.0 g/ms. Mean threshold approached within 3 dB of the asymptote by ages P6-P9. Similarly, response latencies decreased exponentially to within 3% of mature values at ages beyond P9. The half-maturity time constant for peripheral response peak latencies P1, N1, and P2 was comparable to thresholds and ranged from approximately 4.6 to 6.2 days, whereas central peaks (N2, P3, and N3) ranged from 2.9 to 3.4 days. Latency-intensity slopes for P1, N1, and P2 tended to decrease with age, reaching mature values within approximately 100 hours of hatching. Amplitudes increased as a function of age with average growth rates for response peaks ranging from 0.04 to 0.09 microV/day. There was no obvious asymptote to the growth of amplitudes over the ages studied. Amplitude-intensity slopes also increased modestly with age. The results show that gravity receptors are responsive to transient cranial stimuli as early as E19 in the chicken embryo. The functional response of gravity receptors continues to develop for many days after all major morphological structures are in place. Distinct maturational processes can be identified in central and peripheral neural relays. Functional improvements during maturation may result from refinements in the receptor epithelia, improvements in central and peripheral synaptic transmission, increased neural myelination, as well as changes in the mechanical coupling between the cranium and receptor organ.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Prusator, M; Jin, H; Ahmad, S
2016-06-15
Purpose: To evaluate the Monte Carlo simulated beam data with the measured commissioning data for the Mevion S250 proton therapy system. Method: The Mevion S250 proton therapy system utilizes a passive double scattering technique with a unique gantry mounted superconducting accelerator and offers effective proton therapy in a compact design concept. The field shaping system (FSS) includes first scattering foil, range modulator wheel (RMW), second scattering foil and post absorber and offers two field sizes and a total of 24 treatment options from proton range of 5 cm to 32 cm. The treatment nozzle was modeled in detail using TOPASmore » (TOolkit for PArticle Simulation) Monte Carlo code. The timing feathers of the moving modulator wheels were also implemented to generate the Spread Out Bragg Peak (SOBP). The simulation results including pristine Bragg Peak, SOBP and dose profiles were compared with the data measured during beam commissioning. Results: The comparison between the measured data and the simulation data show excellent agreement. For pristine proton Bragg Peaks, the simulated proton range (depth of distal 90%) values agreed well with the measured range values within 1 mm accuracy. The differences of the distal falloffs (depth from distal 80% to 20%) were also found to be less than 1 mm between the simulations and measurements. For the SOBP, the widths of modulation (depth of proximal 95% to distal 90%) were also found to agree with the measurement within 1 mm. The flatness of the simulated and measured lateral profiles was found to be 0.6 % and 1.1 %, respectively. Conclusion: The agreement between simulations and measurements demonstrate that TOPAS could be used as a viable platform to proton therapy applications. The matched simulation results offer a great tool and open opportunity for variety of applications.« less
Ontogeny of Vestibular Compound Action Potentials in the Domestic Chicken
M. Jones, Sherri
2000-01-01
Compound action potentials of the vestibular nerve were measured from the surface of the scalp in 148 chickens (Gallus domesticus). Ages ranged from incubation day 18 (E18) to 22 days posthatch (P22). Responses were elicited using linear acceleration cranial pulses. Response thresholds decreased at an average rate of –0.45 dB/day. The decrease was best fit by an exponential model with half-maturity time constant of 5.1 days and asymptote of approximately –25.9 dB re:1.0 g/ms. Mean threshold approached within 3 dB of the asymptote by ages P6–P9. Similarly, response latencies decreased exponentially to within 3% of mature values at ages beyond P9. The half-maturity time constant for peripheral response peak latencies P1, N1, and P2 was comparable to thresholds and ranged from approximately 4.6 to 6.2 days, whereas central peaks (N2, P3, and N3) ranged from 2.9 to 3.4 days. Latency-intensity slopes for P1, N1, and P2 tended to decrease with age, reaching mature values within approximately 100 hours of hatching. Amplitudes increased as a function of age with average growth rates for response peaks ranging from 0.04 to 0.09 μV/day. There was no obvious asymptote to the growth of amplitudes over the ages studied. Amplitude-intensity slopes also increased modestly with age. The results show that gravity receptors are responsive to transient cranial stimuli as early as E19 in the chicken embryo. The functional response of gravity receptors continues to develop for many days after all major morphological structures are in place. Distinct maturational processes can be identified in central and peripheral neural relays. Functional improvements during maturation may result from refinements in the receptor epithelia, improvements in central and peripheral synaptic transmission, increased neural myelination, as well as changes in the mechanical coupling between the cranium and receptor organ. PMID:11545229
Enhanced magnetocaloric effect tuning efficiency in Ni-Mn-Sn alloy ribbons
NASA Astrophysics Data System (ADS)
Quintana-Nedelcos, A.; Sánchez Llamazares, J. L.; Daniel-Perez, G.
2017-11-01
The present work was undertaken to investigate the effect of microstructure on the magnetic entropy change of Ni50Mn37Sn13 ribbon alloys. Unchanged sample composition and cell parameter of austenite allowed us to study strictly the correlation between the average grain size and the total magnetic field induced entropy change (ΔST). We found that a size-dependent martensitic transformation tuning results in a wide temperature range tailoring (>40 K) of the magnetic entropy change with a reasonably small variation on the peak value of the total field induced entropy change. The peak values varied from 6.0 J kg-1 K-1 to 7.7 J kg-1 K-1 for applied fields up to 2 T. Different tuning efficiencies obtained by diverse MCE tailoring approaches are compared to highlight the advantages of the herein proposed mechanism.
Pulse charging of lead-acid traction cells
NASA Technical Reports Server (NTRS)
Smithrick, J. J.
1980-01-01
Pulse charging, as a method of rapidly and efficiently charging 300 amp-hour lead-acid traction cells for an electric vehicle application was investigated. A wide range of charge pulse current square waveforms were investigated and the results were compared to constant current charging at the time averaged pulse current values. Representative pulse current waveforms were: (1) positive waveform-peak charge pulse current of 300 amperes (amps), discharge pulse-current of zero amps, and a duty cycle of about 50%; (2) Romanov waveform-peak charge pulse current of 300 amps, peak discharge pulse current of 15 amps, and a duty of 50%; and (3) McCulloch waveform peak charge pulse current of 193 amps, peak discharge pulse current of about 575 amps, and a duty cycle of 94%. Experimental results indicate that on the basis of amp-hour efficiency, pulse charging offered no significant advantage as a method of rapidly charging 300 amp-hour lead-acid traction cells when compared to constant current charging at the time average pulse current value. There were, however, some disadvantages of pulse charging in particular a decrease in charge amp-hour and energy efficiencies and an increase in cell electrolyte temperature. The constant current charge method resulted in the best energy efficiency with no significant sacrifice of charge time or amp-hour output. Whether or not pulse charging offers an advantage over constant current charging with regard to the cell charge/discharge cycle life is unknown at this time.
Response analysis of TLD-300 dosimeters in heavy-particle beams.
Loncol, T; Hamal, M; Denis, J M; Vynckier, S; Wambersie, A; Scalliet, P
1996-09-01
In vivo dosimetry is recommended as part of the quality control procedure for treatment verification in radiation therapy. Using thermoluminescence, such controls are planned in the p(65) + Be neutron and 85 MeV proton beams produced at the cyclotron at Louvain-La-Neuve and dedicated to therapy applications. A preliminary study of the peak 3 (150 degrees C) and peak 5 (250 degrees C) response of CaF2:Tm (TLD-300) to neutron and proton beams aimed to analyse the effect of different radiation qualities on the dosimetric behaviour of the detector irradiated in phantom. To broaden the range of investigation, the study was extended to an experimental 12C heavy ion beam (95 MeV/nucleon). The peak 3 and 5 sensitivities in the neutron beam, compared to 60Co, varied little with depth. A major change of peak 5 sensitivity was observed for samples positioned under five leaves of the multi-leaf collimator. While peak 3 sensitivity was constant with depth in the unmodulated proton beam, peak 5 sensitivity increased by 15%. Near the Bragg peak, peak 3 showed the highest decrease of sensitivity. In the modulated proton beam, the sensitivity values were not significantly smaller than those measured in the unmodulated beam far from the Bragg peak region. The ratio of the heights of peak 3 and peak 5 decreased by 70% from the 60Co reference radiation to the 12C heavy-ion beam. This parameter was strongly correlated with the change of radiation quality.
Ventilation by high-frequency chest wall compression in dogs with normal lungs.
Zidulka, A; Gross, D; Minami, H; Vartian, V; Chang, H K
1983-06-01
In 6 anesthetized and paralyzed supine dogs, ventilation by high-frequency chest wall compression (HFCWC) was accomplished by a piston pump rapidly oscillating the pressure in a modified double blood pressure cuff wrapped around the lower thorax. Testing applied frequencies at 3, 5, 8, and 11 Hz, applied peak cuff pressures ranged from 30 to 230 cmH2O. This produced swings of esophageal pressure as high as 18 cmH2O and peak oscillatory air flow ranging from 0.7 to 1.6 L/s. Oscillatory tidal volume declined with increasing frequency and ranged from a mean of 61 to 45 ml. After 30 min of applied HFCWC, arterial blood gas determinations revealed a mean PaCO2 of 29.3 mmHg at 5 Hz, 35 mmHg at 3 Hz, 36 mmHg at 8 Hz, and 51 mmHg at 11 Hz. Mean PaO2 improved from ventilator control values at 3 Hz, remained unchanged at 5 and 8 Hz, and declined at 11 Hz. In 2 dogs breathing spontaneously, HFCWC applied at 5 and 11 Hz resulted in a reduction in spontaneous minute ventilation, mainly by a reduction in spontaneous tidal volume, whereas arterial blood gas values changed slightly. One dog ceased to breath spontaneously within 5 min of application of HFCWC as the PaCO2 fell below control values. We conclude that in dogs with normal lungs, HFCWC may assist spontaneous ventilation. In paralyzed dogs, HFCWC may be of sufficient magnitude to cause hyperventilation.
NASA Astrophysics Data System (ADS)
Prabhu, M.; Unnikrishnan, K.
2018-04-01
In the present work, we analyzed the daytime vertical E × B drift velocities obtained from Jicamarca Unattended Long-term Ionosphere Atmosphere (JULIA) radar and ΔH component of geomagnetic field measured as the difference between the magnitudes of the horizontal (H) components between two magnetometers deployed at two different locations Jicamarca, and Piura in Peru for 22 geomagnetically disturbed events in which either SC has occurred or Dstmax < -50 nT during the period 2006-2011. The ΔH component of geomagnetic field is measured as the differences in the magnitudes of horizontal H component between magnetometer placed directly on the magnetic equator and one displaced 6-9° away. It will provide a direct measure of the daytime electrojet current, due to the eastward electric field. This will in turn gives the magnitude of vertical E × B drift velocity in the F region. A positive correlation exists between peak values of daytime vertical E × B drift velocity and peak value of ΔH for the three consecutive days of the events. It was observed that 45% of the events have daytime vertical E × B drift velocity peak in the magnitude range 10-20 m/s and 20-30 m/s and 20% have peak ΔH in the magnitude range 50-60 nT and 80-90 nT. It was observed that the time of occurrence of the peak value of both the vertical E × B drift velocity and the ΔH have a maximum (40%) probability in the same time range 11:00-13:00 LT. We also investigated the correlation between E × B drift velocity and Dst index and the correlation between delta H and Dst index. A strong positive correlation is found between E × B drift and Dst index as well as between delta H and Dst Index. Three different techniques of data analysis - linear, polynomial (order 2), and polynomial (order 3) regression analysis were considered. The regression parameters in all the three cases were calculated using the Least Square Method (LSM), using the daytime vertical E × B drift velocity and ΔH. A formula was developed which indicates the relationship between daytime vertical E × B drift velocity and ΔH, for the disturbed periods. The E × B drift velocity was then evaluated using the formulae thus found for the three regression analysis and validated for the 'disturbed periods' of 3 selected events. The E × B drift velocities estimated by the three regression analysis have a fairly good agreement with JULIA radar observed values under different seasons and solar activity conditions. Root Mean Square (RMS) errors calculated for each case suggest that polynomial (order 3) regression analysis provides a better agreement with the observations from among the three.
Diurnal centroid of ecosystem energy and carbon fluxes at FLUXNET sites
Kell B. Wilson; Dennis Baldocchi; Eva Falge; Marc Aubinet; Paul Berbigier; Christian Bernhofer; Han Dolman; Chris Field; Allen Goldstein; Andre Granier; Dave Hollinger; Gabriel Katul; B.E. Law; Tilden Meyers; John Moncrieff; Russ Monson; John Tenhunen; Riccardo Valentini; Shashi Verma; Steve Wofsy
2003-01-01
Data from a network of eddy covariance stations in Europe and North America (FLUXNET) were analyzed to examine the diurnal patterns of surface energy and carbon fluxes during the summer period across a range of ecosystems and climates. Diurnal trends were quantified by assessing the time of day surface fluxes and meteorological variable reached peak values, using the...
NASA Astrophysics Data System (ADS)
Godbole, Rohini M.; Kaushik, Abhiram; Misra, Anuradha
2018-04-01
We study the low-virtuality inclusive leptoproduction of open charm, p↑l →D0+X as a probe of the gluon Sivers function. We perform the analysis in a generalized parton model framework. At leading order, this process is sensitive only to the gluon content of the proton. Hence any detection of a transverse single-spin asymmetry in this process would be clear indication of a non-zero gluon Sivers function (GSF). Considering COMPASS and a future Electron-Ion Collider (EIC), we present predictions for asymmetry using fits for the GSF available in literature. Predictions for peak asymmetry values lie in the range of 0.8% to 13%. We also present estimates of the upper bound on the asymmetry as obtained with a maximal gluon Sivers function. Further, for the case of the Electron-Ion Collider, we evaluate the asymmetry in the muons decaying from the D -meson and find that the asymmetry is well preserved in the kinematics of the muons. Peak values of the muon asymmetry are close to those obtained for the D -meson and lie in the range 0.75% to 11%.
Dolphin sonar detection and discrimination capabilities
NASA Astrophysics Data System (ADS)
Au, Whitlow W. L.
2004-05-01
Dolphins have a very sophisticated short range sonar that surpasses all technological sonar in its capabilities to perform complex target discrimination and recognition tasks. The system that the U.S. Navy has for detecting mines buried under ocean sediment is one that uses Atlantic bottlenose dolphins. However, close examination of the dolphin sonar system will reveal that the dolphin acoustic hardware is fairly ordinary and not very special. The transmitted signals have peak-to-peak amplitudes as high as 225-228 dB re 1 μPa which translates to an rms value of approximately 210-213 dB. The transmit beamwidth is fairly broad at about 10o in both the horizontal and vertical planes and the receiving beamwidth is slightly broader by several degrees. The auditory filters are not very narrow with Q values of about 8.4. Despite these fairly ordinary features of the acoustic system, these animals still demonstrate very unusual and astonishing capabilities. Some of the capabilities of the dolphin sonar system will be presented and the reasons for their keen sonar capabilities will be discussed. Important features of their sonar include the broadband clicklike signals used, adaptive sonar search capabilities and large dynamic range of its auditory system.
Magnetic and thermodynamic properties of Nd3NiGe2
NASA Astrophysics Data System (ADS)
Matsumoto, Keisuke T.; Hiraoka, Koichi
2018-05-01
We here report the magnetization, M, and specific heat, C, of Nd3NiGe2 , which crystallizes in the orthorhombic Gd3NiSi2 -type structure. Nd ions occupy three nonequivalent sites in a unit cell. Upon cooling, magnetization divided by magnetic field, M / B , increased sharply at the Curie temperature, TC, of 87 K and below 40 K. The former result indicates that the increase in M / B observed at TC is due to the long-range ferromagnetic order. The increase below 40 K is derived from a short-range correlation because of the absence of clear anomaly in C (T) . At 10 K and 2 K, the values of M undergo metamagnetic transitions. The value of magnetic specific heat divided by temperature shows a shoulder-like anomaly at around 20 K, which is attributed to antiferromagnetic behavior. Furthermore, two peaks in C (T) were observed at 4.5 K and 3.8 K, and these peaks occurred at lower temperatures in the presence of a magnetic field. This behavior is typical of materials with antiferromagnetic order. These observations are attributed to the competition between ferromagnetic and antiferromagnetic interactions, which is a result of the three nonequivalent Nd sites.
NASA Astrophysics Data System (ADS)
Dutta, Rituraj; Kumar, A.
2017-10-01
Dielectric relaxation dynamics and AC conductivity scaling of a metal-organic framework (MOF-5) based poly (vinylidene fluoride-co-hexafluoropropylene) (PVdf-HFP) incorporated with 1-Butyl-3-methylimidazolium hexafluorophosphate have been studied over a frequency range of 40 Hz-5 MHz and in the temperature range of 300 K-380 K. High values of dielectric permittivity (~{{\\varepsilon }\\prime} ) having strong dispersion are obtained at low frequency because of interfacial polarization. The real part of the dielectric modulus spectra (M‧) shows no prominent peak, whereas the imaginary part (M″) shows certain peaks, with a reduction in relaxation time (τ) that can be attributed to a non-Debye relaxation mechanism. The spectra also depict both concentration- and temperature-independent scaling behavior. The power law dependent variation of AC conductivity follows the jump relaxation model and reveals activated ion hopping over diffusion barriers. The value of the frequency exponent is observed to decrease with increasing concentration of ionic liquid, indicating the forward hopping of ions in the relaxation process. The AC conductivity scaling curves at different temperatures also depict the temperature-independent relaxation dynamics.
Rechmann, Peter; Bartolome, N; Kinsel, R; Vaderhobli, R; Rechmann, B M T
2017-12-01
The objective of this study was to evaluate the influence of CO 2 9.3 μm short-pulsed laser irradiation on the shear bond strength of composite resin to enamel and dentin. Two hundred enamel and 210 dentin samples were irradiated with a 9.3 µm carbon dioxide laser (Solea, Convergent Dental, Inc., Natick, MA) with energies which either enhanced caries resistance or were effective for ablation. OptiBond Solo Plus [OptiBondTE] (Kerr Corporation, Orange, CA) and Peak Universal Bond light-cured adhesive [PeakTE] (Ultradent Products, South Jordan, UT) were used. In addition, Scotchbond Universal [ScotchbondSE] (3M ESPE, St. Paul, MN) and Peak SE self-etching primer with Peak Universal Bond light-cured adhesive [PeakSE] (Ultradent Products) were tested. Clearfil APX (Kuraray, New York, NY) was bonded to the samples. After 24 h, a single plane shear bond test was performed. Using the caries preventive setting on enamel resulted in increased shear bond strength for all bonding agents except for self-etch PeakSE. The highest overall bond strength was seen with PeakTE (41.29 ± 6.04 MPa). Etch-and-rinse systems achieved higher bond strength values to ablated enamel than the self-etch systems did. PeakTE showed the highest shear bond strength with 35.22 ± 4.40 MPa. OptiBondTE reached 93.8% of its control value. The self-etch system PeakSE presented significantly lower bond strength. The shear bond strength to dentin ranged between 19.15 ± 3.49 MPa for OptiBondTE and 43.94 ± 6.47 MPa for PeakSE. Etch-and-rinse systems had consistently higher bond strength to CO 2 9.3 µm laser-ablated enamel. Using the maximum recommended energy for dentin ablation, the self-etch system PeakSE reached the highest bond strength (43.9 ± 6.5 MPa).
Seo, Chang-Seob; Kim, Seong-Sil; Ha, Hyekyung
2013-01-01
This study was designed to perform simultaneous determination of three reference compounds in Syzygium aromaticum (SA), gallic acid, ellagic acid, and eugenol, and to investigate the chemical antagonistic effect when combining Curcuma aromatica (CA) with SA, based on chromatographic analysis. The values of LODs and LOQs were 0.01–0.11 μg/mL and 0.03–0.36 μg/mL, respectively. The intraday and interday precisions were <3.0 of RSD values, and the recovery was in the range of 92.19–103.24%, with RSD values <3.0%. Repeatability and stability were 0.38–0.73% and 0.49–2.24%, respectively. Compared with the content of reference and relative peaks in SA and SA combined with CA (SAC), the amounts of gallic acid and eugenol were increased, while that of ellagic acid was decreased in SAC (compared with SA), and most of peak areas in SA were reduced in SAC. Regression analysis of the relative peak areas between SA and SAC showed r 2 values >0.87, indicating a linear relationship between SA and SAC. These results demonstrate that the components contained in CA could affect the extraction of components of SA mainly in a decreasing manner. The antagonistic effect of CA on SA was verified by chemical analysis. PMID:23878761
Impact of Wind and Solar on the Value of Energy Storage
DOE Office of Scientific and Technical Information (OSTI.GOV)
Denholm, Paul; Jorgenson, Jennie; Hummon, Marissa
2013-11-01
This analysis evaluates how the value of energy storage changes when adding variable generation (VG) renewable energy resources to the grid. A series of VG energy penetration scenarios from 16% to 55% were generated for a utility system in the western United States. This operational value of storage (measured by its ability to reduce system production costs) was estimated in each VG scenario, considering provision of different services and with several sensitivities to fuel price and generation mix. Overall, the results found that the presence of VG increases the value of energy storage by lowering off-peak energy prices more thanmore » on-peak prices, leading to a greater opportunity to arbitrage this price difference. However, significant charging from renewables, and consequently a net reduction in carbon emissions, did not occur until VG penetration was in the range of 40%-50%. Increased penetration of VG also increases the potential value of storage when providing reserves, mainly by increasing the amount of reserves required by the system. Despite this increase in value, storage may face challenges in capturing the full benefits it provides. Due to suppression of on-/off-peak price differentials, reserve prices, and incomplete capture of certain system benefits (such as the cost of power plant starts), the revenue obtained by storage in a market setting appears to be substantially less than the net benefit (reduction in production costs) provided to the system. Furthermore, it is unclear how storage will actually incentivize large-scale deployment of renewables needed to substantially increase VG penetration. This demonstrates some of the additional challenges for storage deployed in restructured energy markets.« less
Armstrong, David W J; Matangi, Murray F
2010-02-01
To determine the normal range of estimated right ventricular systolic pressure (RVSP) at peak exercise during exercise stress echocardiography (ExECHO) in a series of consecutive patients referred for the investigation of coronary artery disease. Of 1057 ExECHO examinations over a span of 11 months, 807 met the study criteria. A total of 250 patients were excluded, 188 for missing rest or peak RVSP measurements, 16 for a resting RVSP above 50 mmHg, 16 for nondiagnostic echocardiographic images and the remaining 30 for missing data. The maximal tricuspid regurgitant jet was recorded at rest and following acquisition of the stress images (mean [+/- SD] time 103.1+/-35.2 s). A mean right atrial pressure of 10 mmHg was used in the calculation of RVSP. All data were entered into a cardiology database (CARDIOfile; Registered trademark, Kingston Heart Clinic) for later retrieval and analysis. There were 206 male (58.9+/-12.0 years of age) and 601 female patients (57.4+/-12.0 years of age). Patient age ranged from 18 to 90 years. The mean resting and peak exercise RVSP was 27.8+/-7.8 mmHg and 34.8+/-11.3 mmHg in men, and 27.8+/-7.7 mmHg and 34.6+/-11.7 mmHg in women, respectively. The mean increase in RVSP was 7.0+/-8.8 mmHg in men and 6.7+/-8.9 mmHg in women. The 95% CI for peak RVSP was 12.2 mmHg to 57.4 mmHg in men, and 11.2 mmHg to 58.0 mmHg in women. There was no significant difference in peak RVSP for a normal ExECHO compared with an abnormal ExECHO. RVSP at rest and at peak exercise increased with both age and left atrial size. In individual patients, the RVSP should not increase above the resting value by more than 24.6 mmHg in men and 24.5 mmHg in women. This value was calculated as the increase in RVSP plus 2xSD of the RVSP. Peak RVSP should not exceed 57.4 mmHg in men and 58.0 mmHg in women. If either of these criteria is exceeded, the response of RVSP to exercise should be considered abnormal.
NASA Technical Reports Server (NTRS)
Lauretta, D. S.; Klaue, B.; Blum, J. D.; Buseck, P. R.
2001-01-01
The abundance and isotopic composition of Hg was determined in bulk samples of both the Murchison (CM) and Allende (CV) carbonaceous chondrites using single- and multi-collector inductively coupled plasma mass spectrometry (ICP-MS). The bulk abundances of Hg are 294 6 15 ng/g in Murchison and 30.0 6 1.5 ng/g in Allende. These values are within the range of previous measurements of bulk Hg abundances by neutron activation analysis (NAA). Prior studies suggested that both meteorites contain isotopically anomalous Hg, with d l 96/202Hg values for the anomalous, thermal-release components from bulk samples ranging from 2260 %o to 1440 9/00 in Murchison and from 2620 9/00 to 1540 9/00 in Allende (Jovanovic and Reed, 1976a; 1976b; Kumar and Goel, 1992). Our multi-collector ICP-MS measurements suggest that the relative abundances of all seven stable Hg isotopes in both meteorites are identical to terrestrial values within 0.2 to 0.5 9/00m. On-line thermal-release experiments were performed by coupling a programmable oven with the singlecollector ICP-MS. Powdered aliquots of each meteorite were linearly heated from room temperature to 900 C over twenty-five minutes under an Ar atmosphere to measure the isotopic composition of Hg released fiom the meteorites as a h c t i o n of temperature. In separate experiments, the release profiles of S and Se were determined simultaneously with Hg to constrain the Hg distribution within the meteorites and to evaluate the possibility of Se interferences in previous NAA studies. The Hg-release patterns differ between Allende and Murchison. The Hg-release profile for Allende contains two distinct peaks, at 225" and 343"C, whereas the profile for Murchison has only one peak, at 344 C. No isotopically anomalous Hg was detected in the thermal-release experiments at a precision level of 5 to 30 9/00, depending on the isotope ratio. In both meteorites the Hg peak at ;340"C correlates with a peak in the S-release profile. This correlation suggests that Hg is associated with S-bearing phases and, thus, that HgS is a major Hg-bearing phase in both meteorites. The Hg peak at 225 C for Allende is similar to release patterns of physically adsorbed Hg on silicate and metal grains.
A meta-analysis of clinical electro-oculography values.
Constable, Paul A; Ngo, David; Quinn, Stephen; Thompson, Dorothy A
2017-12-01
The aim of the meta-analysis was to derive a range of mean normal clinical electrooculogram (EOG) values from a systematic review of published EOG studies that followed the guidelines of the ISCEV standard for clinical electro-oculography. A systematic literature review was performed using four relevant databases limited to peer-reviewed articles in English between 1967 and February 2017. Studies reporting clinical EOG or FO normal values were included when the report used a standard 30° horizontal saccade, a retinal luminance of between 100 and 250 cd m -2 , and had > 10 subjects in their normative values. The search identified 1145 articles after duplicates were removed with subsequent screening of the abstracts excluding a further 1098, resulting in 47 full-text articles that were then assessed by the author (PC) with a final nine articles meeting the inclusion criteria. An overall effect estimate using inverse variance-weighted meta-analysis was performed to estimate the mean values for the light peak/dark trough ratio (LP:DT ratio) (dilated and undilated), the time to the LP, the amplitude of the LP, dark trough (DT) and the fast oscillation (FO) peak-to-trough ratio from the included studies. The mean dilated LP:DT ratio was 2.35 (95% CI 2.28-2.42); undilated LP:DT ratio was 2.37 (95% CI 2.28-2.45); LP amplitude was 835 (95% CI 631-1039) µV and the mean time to the LP being 8.2 (95% CI 7.7-8.7) min. The mean DT amplitude was 358 (95% CI 292-424) µV, and the mean FO peak-to-trough ratio was 1.13 (95% CI 1.11-1.16). The results of the LP/DT ratio are drawn from studies with a mean ± standard deviation (SD) age of 34.08 ± 12.93 years for dilated and 33.65 ± 12.28 years for undilated LP/DT ratios. The meta-analysis of EOG studies has generated a reference range of normal mean values for clinicians to refer to when using the ISCEV clinical EOG. It provides a potential method to generate similar data sets from published normal values in related visual electrophysiology tests.
NASA Astrophysics Data System (ADS)
Park, Wan Kyu; Hunt, C. R.; Arham, H. Z.; Lu, X.; Greene, L. H.; Xu, Z. J.; Wen, J. S.; Lin, Z. W.; Li, Q.; Gu, G.
2010-03-01
We report point-contact conductance measurements on the iron chalcogenide superconductors, Fe1+yTe1-xSex. The excess Fe atoms are known to occupy the interstitial sites in the Te-Se plane, affecting the superconductivity as well as the magnetism in this family. For a compound having nominal values of y=0 and x=0.45, a single superconducting transition is observed at 14.2 K. In the superconducting state, BTK-like double peak structures due to Andreev reflection are observed. However, the peak position of different point contacts falls to a wide voltage range, 1.5 -- 4 mV. Additional multiple humps are sometimes observed in a much higher bias voltage range, 8 -- 15 mV. Most strikingly, conductance enhancement persists well above Tc. We will present possible interpretations of these experimental observations in terms of multiband superconductivity and the interplay between superconductivity and magnetism.
Tunability of temperature-dependent absorption in a graphene-based hybrid nanostructure cavity
NASA Astrophysics Data System (ADS)
Rashidi, Arezou; Namdar, Abdolrahman
2018-04-01
Enhanced absorption is obtained in a hybrid nanostructure composed of graphene and one-dimensional photonic crystal as a cavity in the visible wavelength range thanks to the localized electric field around the defect layers. The temperature-induced wavelength shift is revealed in the absorption spectra in which the peak wavelength is red-shifted by increasing the temperature. This temperature dependence comes from the thermal expansion and thermo-optical effects in the constituent layers of the structure. Moreover, the absorption peaks can be adjusted by varying the incident angle. The results show that absorption is sensitive to TE/TM polarization and its peak values for the TE mode are higher than the TM case. Also, the peak wavelength is blue-shifted by increasing the incident angle for both polarizations. Finally, the possibility of tuning the absorption using the electro-optical response of graphene sheets is discussed in detail. We believe our study may be beneficial for designing tunable graphene-based temperature-sensitive absorbers.
Two classes of fast-declining Type Ia supernovae
NASA Astrophysics Data System (ADS)
Dhawan, Suhail; Leibundgut, B.; Spyromilio, J.; Blondin, S.
2017-06-01
We aim to characterise a sample of fast-declining Type Ia supernovae (SN Ia) using their bolometric and near-infrared (NIR) properties. Based on these properties, we find that fast-declining SN Ia separate into two categories based on their bolometric and NIR properties. The peak bolometric luminosity (Lmax), the phase of the first maximum relative to the optical, the NIR peak luminosity, and the occurrence of a second maximum in the NIR distinguish a group of very faint SN Ia. Fast-declining supernovae show a large range of peak bolometric luminosities (Lmax differing by up to a factor of 8). All fast-declining SN Ia with Lmax < 0.3× 1043 erg s-1 are spectroscopically classified as 91bg-like and show only a single NIR peak. SNe with Lmax > 0.5× 1043 erg s-1 appear to smoothly connect to normal SN Ia. The total ejecta mass (Mej) values for SNe with enough late time data are ≲1 M⊙, indicating a sub-Chandrasekhar mass progenitor for these SNe.
Commonly used reference values underestimate oxygen uptake in healthy, 50-year-old Swedish women.
Genberg, M; Andrén, B; Lind, L; Hedenström, H; Malinovschi, A
2018-01-01
Cardiopulmonary exercise testing (CPET) is the gold standard among clinical exercise tests. It combines a conventional stress test with measurement of oxygen uptake (V O 2 ) and CO 2 production. No validated Swedish reference values exist, and reference values in women are generally understudied. Moreover, the importance of achieved respiratory exchange ratio (RER) and the significance of breathing reserve (BR) at peak exercise in healthy individuals are poorly understood. We compared V O 2 at maximal load (peakV O 2 ) and anaerobic threshold (V O 2@ AT ) in healthy Swedish individuals with commonly used reference values, taking gender into account. Further, we analysed maximal workload and peakV O 2 with regard to peak RER and BR. In all, 181 healthy, 50-year-old individuals (91 women) performed CPET. PeakV O 2 was best predicted using Jones et al. (100·5%), while SHIP reference values underestimated peakV O 2 most: 112·5%. Furthermore, underestimation of peakV O 2 in women was found for all studied reference values (P<0·001) and was largest for SHIP: women had 128% of predicted peakV O 2 , while men had 104%. PeakV O 2 was similar in subjects with peak RER of 1-1·1 and RER > 1·1 (2 328·7 versus 2 176·7 ml min -1 , P = 0·11). Lower BR (≤30%) related to significantly higher peakV O 2 (P<0·001). In conclusion, peakV O 2 was best predicted by Jones. All studied reference values underestimated oxygen uptake in women. No evidence for demanding RER > 1·1 in healthy individuals was found. A lowered BR is probably a normal response to higher workloads in healthy individuals. © 2016 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.
Simultaneous Planck , Swift , and Fermi observations of X-ray and γ -ray selected blazars
Giommi, P.; Polenta, G.; Lähteenmäki, A.; ...
2012-05-22
We present simultaneous Planck, Swift, Fermi, and ground-based data for 105 blazars belonging to three samples with flux limits in the soft X-ray, hard X-ray, and γ-ray bands, with additional 5GHz flux-density limits to ensure a good probability of a Planck detection. We compare our results to those of a companion paper presenting simultaneous Planck and multi-frequency observations of 104 radio-loud northern active galactic nuclei selected at radio frequencies. While we confirm several previous results, our unique data set allows us to demonstrate that the selection method strongly influences the results, producing biases that cannot be ignored. Almost all themore » BL Lac objects have been detected by the Fermi Large AreaTelescope (LAT), whereas 30% to 40% of the flat-spectrum radio quasars (FSRQs) in the radio, soft X-ray, and hard X-ray selected samples are still below the γ-ray detection limit even after integrating 27 months of Fermi-LAT data. The radio to sub-millimetre spectral slope of blazars is quite flat, with >α> ~ 0 up to about 70GHz, above which it steepens to ~ -0.65. The BL Lacs have significantly flatter spectra than FSRQs at higher frequencies. The distribution of the rest-frame synchrotron peak frequency (ν peak S) in the spectral energy distribution (SED) of FSRQs is the same in all the blazar samples with peak S> = 10 13.1 ± 0.1 Hz, while the mean inverse Compton peak frequency, >ν peak IC>, ranges from 1021 to 1022 Hz. The distributions of ν peak S and ν peak IC of BL Lacs are much broader and are shifted to higher energies than those of FSRQs; their shapes strongly depend on the selection method. The Compton dominance of blazars, defined as the ratio of the inverse Compton to synchrotron peak luminosities, ranges from less than 0.2 to nearly 100, with only FSRQs reaching values larger than about 3. Its distribution is broad and depends strongly on the selection method, with γ-ray selected blazars peaking at ~7 or more, and radio-selected blazars at values close to 1, thus implying that the common assumption that the blazar power budget is largely dominated by high-energy emission is a selection effect. A comparison of our multi-frequency data with theoretical predictions shows that simple homogeneous SSC models cannot explain the simultaneous SEDs of most of the γ-ray detected blazars in all samples. The SED of the blazars that were not detected by Fermi-LAT may instead be consistent with SSC emission. Our data challenge the correlation between bolometric luminosity and ν peak S predicted by the blazar sequence.« less
Mapping apparent stress and energy radiation over fault zones of major earthquakes
McGarr, A.; Fletcher, Joe B.
2002-01-01
Using published slip models for five major earthquakes, 1979 Imperial Valley, 1989 Loma Prieta, 1992 Landers, 1994 Northridge, and 1995 Kobe, we produce maps of apparent stress and radiated seismic energy over their fault surfaces. The slip models, obtained by inverting seismic and geodetic data, entail the division of the fault surfaces into many subfaults for which the time histories of seismic slip are determined. To estimate the seismic energy radiated by each subfault, we measure the near-fault seismic-energy flux from the time-dependent slip there and then multiply by a function of rupture velocity to obtain the corresponding energy that propagates into the far-field. This function, the ratio of far-field to near-fault energy, is typically less than 1/3, inasmuch as most of the near-fault energy remains near the fault and is associated with permanent earthquake deformation. Adding the energy contributions from all of the subfaults yields an estimate of the total seismic energy, which can be compared with independent energy estimates based on seismic-energy flux measured in the far-field, often at teleseismic distances. Estimates of seismic energy based on slip models are robust, in that different models, for a given earthquake, yield energy estimates that are in close agreement. Moreover, the slip-model estimates of energy are generally in good accord with independent estimates by others, based on regional or teleseismic data. Apparent stress is estimated for each subfault by dividing the corresponding seismic moment into the radiated energy. Distributions of apparent stress over an earthquake fault zone show considerable heterogeneity, with peak values that are typically about double the whole-earthquake values (based on the ratio of seismic energy to seismic moment). The range of apparent stresses estimated for subfaults of the events studied here is similar to the range of apparent stresses for earthquakes in continental settings, with peak values of about 8 MPa in each case. For earthquakes in compressional tectonic settings, peak apparent stresses at a given depth are substantially greater than corresponding peak values from events in extensional settings; this suggests that crustal strength, inferred from laboratory measurements, may be a limiting factor. Lower bounds on shear stresses inferred from the apparent stress distribution of the 1995 Kobe earthquake are consistent with tectonic-stress estimates reported by Spudich et al. (1998), based partly on slip-vector rake changes.
Prelaunch optical characterization of the Laser Geodynamic Satellite (LAGEOS 2)
NASA Technical Reports Server (NTRS)
Minott, Peter O.; Zagwodzki, Thomas W.; Varghese, Thomas; Seldon, Michael
1993-01-01
The optical range correction (the distance between the apparent retroreflective skin of the satellite and the center of mass) of the LAGEOS 2 was determined using computer analysis of theoretical and experimentally measured far field diffraction patterns, and with short pulse lasers using both streak camera-based range receivers and more conventional PMT-based range receivers. The three measurement techniques yielded range correction values from 248 to 253 millimeters dependent on laser wavelength, pulsewidth, and polarization, location of the receiver in the far field diffraction pattern and detection technique (peak, half maximum, centroid, or constant fraction). The Lidar cross section of LAGEOS 2 was measured at 4 to 10 million square meters, comparable to the LAGEOS 1.
Influence of angular acceleration-deceleration pulse shapes on regional brain strains.
Yoganandan, Narayan; Li, Jianrong; Zhang, Jiangyue; Pintar, Frank A; Gennarelli, Thomas A
2008-07-19
Recognizing the association of angular loading with brain injuries and inconsistency in previous studies in the application of the biphasic loads to animal, physical, and experimental models, the present study examined the role of the acceleration-deceleration pulse shapes on region-specific strains. An experimentally validated two-dimensional finite element model representing the adult male human head was used. The model simulated the skull and falx as a linear elastic material, cerebrospinal fluid as a hydrodynamic material, and cerebrum as a linear viscoelastic material. The angular loading matrix consisted coronal plane rotation about a center of rotation that was acceleration-only (4.5 ms duration, 7.8 krad/s/s peak), deceleration-only (20 ms, 1.4 krad/s/s peak), acceleration-deceleration, and deceleration-acceleration pulses. Both biphasic pulses had peaks separated by intervals ranging from 0 to 25 ms. Principal strains were determined at the corpus callosum, base of the postcentral sulcus, and cerebral cortex of the parietal lobe. The cerebrum was divided into 17 regions and peak values of average maximum principal strains were determined. In all simulations, the corpus callosum responded with the highest strains. Strains were the least under all simulations in the lower parietal lobes. In all regions peak strains were the same for both monophase pulses suggesting that the angular velocity may be a better metric than peak acceleration or deceleration. In contrast, for the biphasic pulse, peak strains were region- and pulse-shape specific. Peak values were lower in both biphasic pulses when there was no time separation between the pulses than the corresponding monophase pulse. Increasing separation time intervals increased strains, albeit non-uniformly. Acceleration followed by deceleration pulse produced greater strains in all regions than the other form of biphasic pulse. Thus, pulse shape appears to have an effect on regional strains in the brain.
Tanaka, Kazunori; Ogawa, Munehiro; Inagaki, Yusuke; Tanaka, Yasuhito; Nishikawa, Hitoshi; Hattori, Koji
2017-05-01
The Lachman test is clinically considered to be a reliable physical examination for anterior cruciate ligament (ACL) deficiency. However, the test involves subjective judgement of differences in tibial translation and endpoint quality. An auscultation system has been developed to allow assessment of the Lachman test. The knee joint sound during the Lachman test was analyzed using fast Fourier transformation. The purpose of the present study was to quantitatively evaluate knee joint sounds in healthy and ACL-deficient human knees. Sixty healthy volunteers and 24 patients with ACL injury were examined. The Lachman test with joint auscultation was evaluated using a microphone. Knee joint sound during the Lachman test (Lachman sound) was analyzed by fast Fourier transformation. As quantitative indices of the Lachman sound, the peak sound (Lachman peak sound) as the maximum relative amplitude (acoustic pressure) and its frequency were used. In healthy volunteers, the mean Lachman peak sound of intact knees was 100.6 Hz in frequency and -45 dB in acoustic pressure. Moreover, a sex difference was found in the frequency of the Lachman peak sound. In patients with ACL injury, the frequency of the Lachman peak sound of the ACL-deficient knees was widely dispersed. In the ACL-deficient knees, the mean Lachman peak sound was 306.8 Hz in frequency and -63.1 dB in acoustic pressure. If the reference range was set at the frequency of the healthy volunteer Lachman peak sound, the sensitivity, specificity, positive predictive value, and negative predictive value were 83.3%, 95.6%, 95.2%, and 85.2%, respectively. Knee joint auscultation during the Lachman test was capable of judging ACL deficiency on the basis of objective data. In particular, the frequency of the Lachman peak sound was able to assess ACL condition. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
Peak Dose Assessment for Proposed DOE-PPPO Authorized Limits
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maldonado, Delis
2012-06-01
The Oak Ridge Institute for Science and Education (ORISE), a U.S. Department of Energy (DOE) prime contractor, was contracted by the DOE Portsmouth/Paducah Project Office (DOE-PPPO) to conduct a peak dose assessment in support of the Authorized Limits Request for Solid Waste Disposal at Landfill C-746-U at the Paducah Gaseous Diffusion Plant (DOE-PPPO 2011a). The peak doses were calculated based on the DOE-PPPO Proposed Single Radionuclides Soil Guidelines and the DOE-PPPO Proposed Authorized Limits (AL) Volumetric Concentrations available in DOE-PPPO 2011a. This work is provided as an appendix to the Dose Modeling Evaluations and Technical Support Document for the Authorizedmore » Limits Request for the C-746-U Landfill at the Paducah Gaseous Diffusion Plant, Paducah, Kentucky (ORISE 2012). The receptors evaluated in ORISE 2012 were selected by the DOE-PPPO for the additional peak dose evaluations. These receptors included a Landfill Worker, Trespasser, Resident Farmer (onsite), Resident Gardener, Recreational User, Outdoor Worker and an Offsite Resident Farmer. The RESRAD (Version 6.5) and RESRAD-OFFSITE (Version 2.5) computer codes were used for the peak dose assessments. Deterministic peak dose assessments were performed for all the receptors and a probabilistic dose assessment was performed only for the Offsite Resident Farmer at the request of the DOE-PPPO. In a deterministic analysis, a single input value results in a single output value. In other words, a deterministic analysis uses single parameter values for every variable in the code. By contrast, a probabilistic approach assigns parameter ranges to certain variables, and the code randomly selects the values for each variable from the parameter range each time it calculates the dose (NRC 2006). The receptor scenarios, computer codes and parameter input files were previously used in ORISE 2012. A few modifications were made to the parameter input files as appropriate for this effort. Some of these changes included increasing the time horizon beyond 1,050 years (yr), and using the radionuclide concentrations provided by the DOE-PPPO as inputs into the codes. The deterministic peak doses were evaluated within time horizons of 70 yr (for the Landfill Worker and Trespasser), 1,050 yr, 10,000 yr and 100,000 yr (for the Resident Farmer [onsite], Resident Gardener, Recreational User, Outdoor Worker and Offsite Resident Farmer) at the request of the DOE-PPPO. The time horizons of 10,000 yr and 100,000 yr were used at the request of the DOE-PPPO for informational purposes only. The probabilistic peak of the mean dose assessment was performed for the Offsite Resident Farmer using Technetium-99 (Tc-99) and a time horizon of 1,050 yr. The results of the deterministic analyses indicate that among all receptors and time horizons evaluated, the highest projected dose, 2,700 mrem/yr, occurred for the Resident Farmer (onsite) at 12,773 yr. The exposure pathways contributing to the peak dose are ingestion of plants, external gamma, and ingestion of milk, meat and soil. However, this receptor is considered an implausible receptor. The only receptors considered plausible are the Landfill Worker, Recreational User, Outdoor Worker and the Offsite Resident Farmer. The maximum projected dose among the plausible receptors is 220 mrem/yr for the Outdoor Worker and it occurs at 19,045 yr. The exposure pathways contributing to the dose for this receptor are external gamma and soil ingestion. The results of the probabilistic peak of the mean dose analysis for the Offsite Resident Farmer indicate that the average (arithmetic mean) of the peak of the mean doses for this receptor is 0.98 mrem/yr and it occurs at 1,050 yr. This dose corresponds to Tc-99 within the time horizon of 1,050 yr.« less
Relationships between Electroencephalographic Spectral Peaks Across Frequency Bands
van Albada, S. J.; Robinson, P. A.
2013-01-01
The degree to which electroencephalographic spectral peaks are independent, and the relationships between their frequencies have been debated. A novel fitting method was used to determine peak parameters in the range 2–35 Hz from a large sample of eyes-closed spectra, and their interrelationships were investigated. Findings were compared with a mean-field model of thalamocortical activity, which predicts near-harmonic relationships between peaks. The subject set consisted of 1424 healthy subjects from the Brain Resource International Database. Peaks in the theta range occurred on average near half the alpha peak frequency, while peaks in the beta range tended to occur near twice and three times the alpha peak frequency on an individual-subject basis. Moreover, for the majority of subjects, alpha peak frequencies were significantly positively correlated with frequencies of peaks in the theta and low and high beta ranges. Such a harmonic progression agrees semiquantitatively with theoretical predictions from the mean-field model. These findings indicate a common or analogous source for different rhythms, and help to define appropriate individual frequency bands for peak identification. PMID:23483663
Effect of area ratio on the performance of a 5.5:1 pressure ratio centrifugal impeller
NASA Technical Reports Server (NTRS)
Schumann, L. F.; Clark, D. A.; Wood, J. R.
1986-01-01
A centrifugal impeller which was initially designed for a pressure ratio of approximately 5.5 and a mass flow rate of 0.959 kg/sec was tested with a vaneless diffuser for a range of design point impeller area ratios from 2.322 to 2.945. The impeller area ratio was changed by successively cutting back the impeller exit axial width from an initial value of 7.57 mm to a final value of 5.97 mm. In all, four separate area ratios were tested. For each area ratio a series of impeller exit axial clearances was also tested. Test results are based on impeller exit surveys of total pressure, total temperature, and flow angle at a radius 1.115 times the impeller exit radius. Results of the tests at design speed, peak efficiency, and an exit tip clearance of 8 percent of exit blade height show that the impeller equivalent pressure recovery coefficient peaked at a design point area ratio of approximately 2.748 while the impeller aerodynamic efficiency peaked at a lower value of area ratio of approximately 2.55. The variation of impeller efficiency with clearance showed expected trends with a loss of approximately 0.4 points in impeller efficiency for each percent increase in exit axial tip clearance for all impellers tested.
Indetermination of particle sizing by laser diffraction in the anomalous size ranges
NASA Astrophysics Data System (ADS)
Pan, Linchao; Ge, Baozhen; Zhang, Fugen
2017-09-01
The laser diffraction method is widely used to measure particle size distributions. It is generally accepted that the scattering angle becomes smaller and the angles to the location of the main peak of scattered energy distributions in laser diffraction instruments shift to smaller values with increasing particle size. This specific principle forms the foundation of the laser diffraction method. However, this principle is not entirely correct for non-absorbing particles in certain size ranges and these particle size ranges are called anomalous size ranges. Here, we derive the analytical formulae for the bounds of the anomalous size ranges and discuss the influence of the width of the size segments on the signature of the Mie scattering kernel. This anomalous signature of the Mie scattering kernel will result in an indetermination of the particle size distribution when measured by laser diffraction instruments in the anomalous size ranges. By using the singular-value decomposition method we interpret the mechanism of occurrence of this indetermination in detail and then validate its existence by using inversion simulations.
Effect of external magnetic field on locking range of spintronic feedback nano oscillator
NASA Astrophysics Data System (ADS)
Singh, Hanuman; Konishi, K.; Bose, A.; Bhuktare, S.; Miwa, S.; Fukushima, A.; Yakushiji, K.; Yuasa, S.; Kubota, H.; Suzuki, Y.; Tulapurkar, A. A.
2018-05-01
In this work we have studied the effect of external applied magnetic field on the locking range of spintronic feedback nano oscillator. Injection locking of spintronic feedback nano oscillator at integer and fractional multiple of its auto oscillation frequency was demonstrated recently. Here we show that the locking range increases with increasing external magnetic field. We also show synchronization of spintronic feedback nano oscillator at integer (n=1,2,3) multiples of auto oscillation frequency and side band peaks at higher external magnetic field values. We have verified experimental results with macro-spin simulation using similar conditions as used for the experimental study.
Urso, Elena; Le Pera, Maria; Bossio, Sabrina; Sprovieri, Teresa; Qualtieri, Antonio
2010-07-01
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) has been applied to the analysis of a wide range of biomolecules. To date, there are two specific areas of application where MALDI-TOF-MS is viewed as impractical: analysis of low-mass analytes and relative quantitative applications. However, these limitations can be overcome and quantification can be routine. Increased levels of thymosin beta(4) (TB4) have been recently found in cerebrospinal fluid (CSF) from Creutzfeldt-Jakob disease (CJD) patients. Our objective was to apply a label-free quantitative application of MALDI-TOF-MS to measure TB4 levels in human CSF by adding the oxidized form of TB4 as an internal standard. The relative peak area or peak height ratios of the native TB4 to the added oxidized form were evaluated. Considering the relative peak area ratios, healthy individuals showed a mean value of 40.8+/-21.27 ng/ml, whereas CJD patients showed high values with a mean of 154+/-59.07 ng/ml, in agreement with the previous observation found in CJD patients. Similar results were obtained considering peak height ratios. The proposed method may provide a simple and rapid screening method for quantification on CSF of TB4 levels suitable for diagnostic purposes. 2010 Elsevier Inc. All rights reserved.
[Kriging analysis of vegetation index depression in peak cluster karst area].
Yang, Qi-Yong; Jiang, Zhong-Cheng; Ma, Zu-Lu; Cao, Jian-Hua; Luo, Wei-Qun; Li, Wen-Jun; Duan, Xiao-Fang
2012-04-01
In order to master the spatial variability of the normal different vegetation index (NDVI) of the peak cluster karst area, taking into account the problem of the mountain shadow "missing" information of remote sensing images existing in the karst area, NDVI of the non-shaded area were extracted in Guohua Ecological Experimental Area, in Pingguo County, Guangxi applying image processing software, ENVI. The spatial variability of NDVI was analyzed applying geostatistical method, and the NDVI of the mountain shadow areas was predicted and validated. The results indicated that the NDVI of the study area showed strong spatial variability and spatial autocorrelation resulting from the impact of intrinsic factors, and the range was 300 m. The spatial distribution maps of the NDVI interpolated by Kriging interpolation method showed that the mean of NDVI was 0.196, apparently strip and block. The higher NDVI values distributed in the area where the slope was greater than 25 degrees of the peak cluster area, while the lower values distributed in the area such as foot of the peak cluster and depression, where slope was less than 25 degrees. Kriging method validation results show that interpolation has a very high prediction accuracy and could predict the NDVI of the shadow area, which provides a new idea and method for monitoring and evaluation of the karst rocky desertification.
Influence of 10 % Cold Rolling Reduction on Ageing Behaviour of Hot Rolled Al-Cu-Si-Mn-Mg Alloy
NASA Astrophysics Data System (ADS)
Ghosh, S. K.
2014-10-01
In the current study, the effect of 10 % cold rolling on the different ageing phenomena of Al-Cu-Si-Mn-Mg alloy was investigated. Both hot rolled and cold rolled alloys were subjected to both natural and artificial ageing processes. Hardness was measured to understand the change in the mechanical property of the alloy before and after rolling and also during ageing processes. From microscopy, it was evident that the cold rolling and subsequent ageing provided the alloy with a structure in which CuAl2 precipitates were uniformly distributed. The alloy exhibited the peak hardness value of 92 VHN after 2 days of natural ageing, whereas the cold deformed (10 %) alloy exhibited the higher peak hardness value of 139 VHN after 3 days of natural ageing. Peak hardness of the alloy reached 94 VHN, when hot rolled alloy was subjected to ageing at 250 °C for 1 h, whereas 10 % cold rolling followed by ageing (100 °C, 15 min) demonstrated accelerated and elevated hardening. The ageing behaviours thus obtained permit the alloy to provide a range of desirable combinations of strength and ductility for high strength weight saving applications.
Physicochemical properties and digestibility of common bean (Phaseolus vulgaris L.) starches.
Du, Shuang-Kui; Jiang, Hongxin; Ai, Yongfeng; Jane, Jay-Lin
2014-08-08
Physicochemical properties and digestibility of pinto bean, red kidney bean, black bean and navy bean starches were analyzed. All the common bean starches had oval and spherical granules with average diameter of 25.3-27.4 μm. Amylose contents were 32.0-45.4%. Black bean starch showed the highest peak viscosity, breakdown, final viscosity and setback, whereas red kidney bean starch showed the lowest pasting temperature, peak viscosity, breakdown, and setback. Pinto bean starch showed the highest onset and peak gelatinization temperatures, and the lowest gelatinization temperature range; whereas navy bean starch exhibited the lowest values. Amylopectin of red kidney bean had the highest molecular weight (Mw) and z-average gyration radius (Rz), whereas black bean amylopectin had the lowest values of Mw and Rz. The proportions of DP 6-12, DP 13-24, DP 25-36, and DP ≥ 37 and average branch-chain lengths were 23.30-35.21%, 47.79-53.53%, 8.99-12.65%, 6.39-13.49%, and 17.91-21.56, respectively. All the native bean starches were highly resistant to enzyme digestion. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Sugita, Satoshi; Yamaoka, Kazutaka; Ohno, Masanori; Tashiro, Makoto S.; Nakagawa, Yujin E.; Urata, Yuji; Pal'Shin, Valentin; Golenetskii, Sergei; Sakamoto, Takanori; Cummings, Jay; Krimm, Hans; Stamatikos, Michael; Parsons, Ann; Barthelmy, Scott; Gehrels, Neil
2009-06-01
We present the results of the high-redshift GRB 050904 at z = 6.295 from joint spectral analysis among Swift-BAT, Konus-Wind, and Suzaku-WAM, covering a wide energy range of 15--5000keV. The νFu spectrum peak energy, Epeak, was measured at 314+173-89 keV, corresponding to 2291+1263-634 keV in the source frame, and the isotropic equivalent radiated energy, Eiso, was estimated to be 1.04+0.25-0.17 × 1054erg. Both are among the highest values that have ever been measured. GRBs with such a high Eiso (˜1054erg) might be associated with prompt optical emission. The derived spectral and energetic parameters are consistent with the correlation between the rest-frame Ep,i and the Eiso (Amati relation), but not with the correlation between the intrinsic peak energy Ep,i and the collimation-corrected energy Eγ (Ghirlanda relation), unless the density of the circumburst environment of this burst is much larger than the nominal value, as suggested by other wavelength observations. We also discuss the possibility that this burst is an outlier in the correlation between Ep,i and the peak luminosity Lp (Yonetoku relation).
Singh, Michele D; Morris, Michael J; Guimarães, Diva Anelie; Bourne, Gregory; Garcia, Gary W
2016-12-01
The objective of this study was to evaluate serum progesterone (P4) and 17β estradiol (E2) concentrations throughout the estrous cycle in the red-rumped agouti (Dasyprocta leporina). A total of eight multiparous, captive-bred females were bled throughout their estrous cycle via saphenous venipuncture, with E2 and P4 concentrations being measured via ELISA of the serum collected. Serum E 2 ranged from 1212 to 3500pg/ml with a peak value coinciding with observed estrus. However, two additional peak values for E 2 were also recorded, one each in metestrus and proestrus respectively. P4 concentrations reached a maximum of 4.23ng/ml, and increases in P4 immediately followed the second E2 peak in metestrus. The highest concentrations of P4 were recorded in mid diestrus; between days 23-25 of the 31-day cycle. This phase was the longest in the agouti, consisting of approximately 19days and accounted for 61% of the cycle. This study increased the basal scientific reproductive knowledge of this potentially valuable neo-tropical species. Copyright © 2016 Elsevier B.V. All rights reserved.
Measurement and simulation of the RHIC abort kicker longitudinal impedence
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abreu,N.P.; Hahn,H.; Choi, E.
2009-09-01
In face of the new upgrades for RHIC the longitudinal impedance of the machine plays an important role in setting the threshold for instabilities and the efficacy of some systems. In this paper we describe the measurement of the longitudinal impedance of the abort kicker for RHIC as well as computer simulations of the structure. The impedance measurement was done by the S{sub 21} wire method covering the frequency range from 9 kHz to 2.5 GHz. We observed a sharp resonance peak around 10 MHz and a broader peak around 20 MHz in both, the real and imaginary part, ofmore » the Z/n. These two peaks account for a maximum imaginary longitudinal impedance of j15 {Omega}, a value an order of magnitude larger than the estimated value of j0.2 {Omega}, which indicates that the kicker is one of the main sources of longitudinal impedance in the machine. A computer model was constructed for simulations in the CST MWS program. Results for the magnet input and the also the beam impedance are compared to the measurements. A more detail study of the system properties and possible changes to reduce the coupling impedance are presented.« less
Determination of the measurement threshold in gamma-ray spectrometry.
Korun, M; Vodenik, B; Zorko, B
2017-03-01
In gamma-ray spectrometry the measurement threshold describes the lover boundary of the interval of peak areas originating in the response of the spectrometer to gamma-rays from the sample measured. In this sense it presents a generalization of the net indication corresponding to the decision threshold, which is the measurement threshold at the quantity value zero for a predetermined probability for making errors of the first kind. Measurement thresholds were determined for peaks appearing in the spectra of radon daughters 214 Pb and 214 Bi by measuring the spectrum 35 times under repeatable conditions. For the calculation of the measurement threshold the probability for detection of the peaks and the mean relative uncertainty of the peak area were used. The relative measurement thresholds, the ratios between the measurement threshold and the mean peak area uncertainty, were determined for 54 peaks where the probability for detection varied between some percent and about 95% and the relative peak area uncertainty between 30% and 80%. The relative measurement thresholds vary considerably from peak to peak, although the nominal value of the sensitivity parameter defining the sensitivity for locating peaks was equal for all peaks. At the value of the sensitivity parameter used, the peak analysis does not locate peaks corresponding to the decision threshold with the probability in excess of 50%. This implies that peaks in the spectrum may not be located, although the true value of the measurand exceeds the decision threshold. Copyright © 2017 Elsevier Ltd. All rights reserved.
Variation in light intensity with height and time from subsequent lightning return strokes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jordan, D.M.; Uman, M.A.
1983-08-20
Relative light intensity has been measured photographically as a function of height and time for seven subsequent return strokes in two lightning flashes at ranges of 7.8 and 8.7 km. The film used was Kodak 5474 Shellburst, which has a roughly constant spectral response between 300 and 670 nm. The time resolution was about 1.0 ..mu..s, and the spatial resolution was about 4 m. The observed light signals consisted of a fast rise to peak, followed by a slower decrease to a relatively constant value. The amplitude of the initial light peak decreases exponentially with height with a decay constantmore » of about 0.6 to 0.8 km. The 20% to 80% rise time of the initial light signal is between 1 and 4 ..mu..s near ground and increases by an additional 1 to 2 ..mu..s by the time the return stroke reaches the cloud base, a height between 1 and 2 km. The light intensity 30 ..mu..s after the initial peak is relatively constant with height and has an amplitude that is 15% to 30% of the initial peak near the ground and 50% to 100% of the initial peak at cloud base. The logarithm of the peak light intensity near the ground is roughly proportional to the initial peak electric field intensity, and this in turn implies that the current decrease with height may be much slower than the light decrease. The absolute light intensity has been estimated by integrating the photographic signals from individual channel segments to simulate the calibrated all-sky photoelectric data of Guo and Krider (1982). Using this method, the authors find that the mean peak radiance near the ground is 8.3 x 10/sup 5/ W/m, with a total range from 1.4 x 10/sup 5/ to 3.8 x 10/sup 6/ W/m. 16 references, 11 figures.« less
Acoustic-based proton range verification in heterogeneous tissue: simulation studies
NASA Astrophysics Data System (ADS)
Jones, Kevin C.; Nie, Wei; Chu, James C. H.; Turian, Julius V.; Kassaee, Alireza; Sehgal, Chandra M.; Avery, Stephen
2018-01-01
Acoustic-based proton range verification (protoacoustics) is a potential in vivo technique for determining the Bragg peak position. Previous measurements and simulations have been restricted to homogeneous water tanks. Here, a CT-based simulation method is proposed and applied to a liver and prostate case to model the effects of tissue heterogeneity on the protoacoustic amplitude and time-of-flight range verification accuracy. For the liver case, posterior irradiation with a single proton pencil beam was simulated for detectors placed on the skin. In the prostate case, a transrectal probe measured the protoacoustic pressure generated by irradiation with five separate anterior proton beams. After calculating the proton beam dose deposition, each CT voxel’s material properties were mapped based on Hounsfield Unit values, and thermoacoustically-generated acoustic wave propagation was simulated with the k-Wave MATLAB toolbox. By comparing the simulation results for the original liver CT to homogenized variants, the effects of heterogeneity were assessed. For the liver case, 1.4 cGy of dose at the Bragg peak generated 50 mPa of pressure (13 cm distal), a 2× lower amplitude than simulated in a homogeneous water tank. Protoacoustic triangulation of the Bragg peak based on multiple detector measurements resulted in 0.4 mm accuracy for a δ-function proton pulse irradiation of the liver. For the prostate case, higher amplitudes are simulated (92-1004 mPa) for closer detectors (<8 cm). For four of the prostate beams, the protoacoustic range triangulation was accurate to ⩽1.6 mm (δ-function proton pulse). Based on the results, application of protoacoustic range verification to heterogeneous tissue will result in decreased signal amplitudes relative to homogeneous water tank measurements, but accurate range verification is still expected to be possible.
Effect of dopant on electrical properties of PVA doped NaF polymer electrolyte films
NASA Astrophysics Data System (ADS)
Irfan, Mohammed; Razikha Banu, S.; Manjunath, A.; Mahesh, S. S.
2018-05-01
Polymer electrolyte films of Poly (vinyl alcohol) (PVA) doped with Sodium fluoride (NaF) of different weight ratios (6, 8 and 10 wt %) were prepared by solution casting method. We observed that AC conductivity was found to increase with rise in temperature and frequency with slope S ranging from 0.7 to 0.9. The Correlated Barrier Hopping (CBH) model is used because the value of S is temperature dependent and its value decreases by increasing temperature. The dielectric constant has high values in the low frequency region; this is due to the existence of various types of polarization mechanisms. The X-ray diffraction (XRD) diagram of pure PVA shows a characteristic peak at 2θ=19.490 indicating its semi-crystalline nature. On the incorporation of NaF salt into the polymer, the intensity of peak decreases gradually, suggesting a decrease in the degree of crystallinity of the complex. The CBH model is used to calculate the polaron binding energy (WM), the Hoping distance (R), the minimum hoping distance (Rmin) and the activation energy (Ea) results are discussed.
McGhie, Jackie S; Menting, Myrthe E; Vletter, Wim B; Frowijn, René; Roos-Hesselink, Jolien W; van der Zwaan, Heleen B; Soliman, Osama I I; Geleijnse, Marcel L; van den Bosch, Annemien E
2017-07-01
The aim of this prospective study was to evaluate the feasibility and establish normal values of functional right ventricle (RV) parameters as assessed in our four, long-axis view RV model using iRotate echocardiography. Furthermore, we evaluated the potential use of this model in patients with abnormally loaded RVs. One hundred and fifty-five healthy subjects aged 20-72 years (≥28 subjects per decile) were prospectively recruited. We used non-dedicated RV speckle-tracking software to test the feasibility and to establish normal range values of peak systolic global longitudinal RV strain (RV-GLS) from the RV free-walls (septum was excluded). Also normal range values for: dimensions, tricuspid annular plane systolic excursion (TAPSE) and tricuspid annular peak systolic velocity (TDI-S') were established. The feasibility of RV-GLS was 88, 84, and 62%, respectively, in the lateral, inferior, and anterior free wall. Mean RV-GLS normal values were -24.5 ± 4.9% for lateral wall and -25.4 ± 5.0% for anterior wall. Mean RV-GLS in the inferior wall was -23.2 ± 4.4% in the aortic (Ao) view and -20.7 ± 5.0% in the coronal (CV) view. The feasibility of mean RV-GLS was 100% in the anterior, lateral, and inferior walls in abnormally dilated RVs. The feasibility of all RV parameters assessed in the four-view iRotate model is good to excellent. Normal values for RV dimension and function of the anterior, inferior, and lateral RV walls have been established. Further studies and dedicated RV speckle-tracking software are warranted to discover the full potential of this new technique. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions, please email: journals.permissions@oup.com.
Dielectric Properties of PMMA and its Composites with ZrO2
NASA Astrophysics Data System (ADS)
Sannakki, Basavaraja; Anita
The polymer films of PMMA with different thickness and its composites with ZrO2 at various weight percentages but of same thickness have been studied. The determination of its dielectric properties, dielectric loss, a.conductivity and dielectric modulus were carried out using capacitance measurements of the above samples as a function of frequency, over the range 50 Hz - 5 MHz at room temperature. The films of PMMA and its composites have been characterized using X-Ray Diffractometer. The dielectric permittivity of films of PMMA behaves nonlinearly as frequency increases over the range 50-300 Hz, where as above 300 Hz the values of dielectric constant remains constant. But it is observed that the dielectric constant of PMMA increases as thickness of the film increases. In case of composite films of PMMA with ZrO2 the values of dielectric permittivity decreases gradually up to frequency of around 1 KHz and at higher frequencies it remains constant for all the weight percentages of ZrO2. The complex form of dielectric modulus of PMMA is obtained from the experimentally measured data of dielectric constant and dielectric loss values. The relaxation time of the orientation of dipoles is obtained from the peak value of angular frequency through the plots of imaginary part of electrical modulus as function of frequency. The impedance of PMMA polymer increases as thickness of the films increases. The a c conductivity of PMMA film remains constant up to frequency of 1 MHz and above. It shows a nonlinear phenomenon with peak values at frequency 4 MHz. Shape and size of the nanoparticles of composite film of PMMA with ZrO2 was analyzed by Field Emission Scanning Electron Microscope (FESEM).
Physical and physiological demands in women pole dance: a single case study.
Ruscello, Bruno; Iannelli, Sara; Partipilo, Filippo; Esposito, Mario; Pantanella, Laura; Dring, Mary B; D'Ottavio, Stefano
2017-04-01
to investigate the physical and physiological demands of a pole dancer's performance studied during a simulated competition, lasting 3 min 30 sec. one single woman pole dancer, (age: 22 years; height: 1.56m; body weight: 52kg; BMI: 21.4kg·m-2; estimated HRmax:192.6 bpm) participated in the study. Physical data pertaining to accelerations and rotational values were collected by the means of a tri-axial accelerometer device integrating three gyroscopes. A complete video footage was recorded using four video cameras, using different sampling rates. Blood Pressure, Heart Rates, Breathing Rates, Blood Lactate concentrations were recorded during the performance. Accelerations (positive and negative), along the vertical axis reached 2G and rotational movements around the pole, reached 400°/s. Blood Pressure values ranged from 120/75 before and to 145/58 mmHg at the end of performance, respectively. Heart Rates reached a peak value of 96% of the Maximal Estimated Heart Rate (HRmax) and a mean %HRmax of 92.85 ± 3.15% during the simulated competition. Breathing Rate reached a peak value of 37 bpm and a mean value during competition of 31.87±3.42 bpm. Blood Lactate concentration ranged from 10.2 to 10.7 mmol/L measured at 1 min and 5 min after the completion of the competition, respectively. The results of this case study confirm that the Pole Dance is a performing art requiring heavy physiological and physical demands on the performers. Specific training routines should be designed in order to cope efficiently with this physical activity, taking into account the performance model we provided with this study.
NASA Astrophysics Data System (ADS)
Gordiyenko, G. I.; Yakovets, A. F.
2017-07-01
The ionospheric F2 peak parameters recorded by a ground-based ionosonde at the midlatitude station Alma-Ata [43.25N, 76.92E] were compared with those obtained using the latest version of the IRI model (http://omniweb.gsfc.nasa.gov/vitmo/iri2012_vitmo.html). It was found that for the Alma-Ata (Kazakhstan) location, the IRI2012 model describes well the morphology of seasonal and diurnal variations of the ionospheric critical frequency (foF2) and peak density height (hmF2) monthly medians. The model errors in the median foF2 prediction (percentage deviations between the median foF2 values and their model predictions) were found to vary approximately in the range from about -20% to 34% and showed a stable overestimation in the median foF2 values for daytime in January and July and underestimation for day- and nighttime hours in the equinoctial months. The comparison between the ionosonde hmF2 and IRI results clearly showed that the IRI overestimates the nighttime hmF2 values for March and September months, and the difference is up to 30 km. The daytime Alma-Ata hmF2 data were found to be close to the IRI predictions (deviations are approximately ±10-15 km) in winter and equinoctial months, except in July when the observed hmF2 values were much more (from approximately 50-200 km). The comparison between the Alouette foF2 data and IRI predictions showed mixed results. In particular, the Alouette foF2 data showed a tendency to be overestimated for daytime in winter months similar to the ionosonde data; however, the overestimated foF2 values for nighttime in the autumn equinox were in disagreement with the ionosonde observations. There were large deviations between the observed hmF2 values and their model predictions. The largest deviations were found during winter and summer (up to -90 km). The comparison of the Alouette II electron density profiles with those predicted by the adapted IRI2012 model in the altitude range hmF2 of the satellite position showed a great difference in the shape of the Alouette-, NeQuick-, IRI02-coorr, and IRI2001-derived Ne profiles, with overestimated Ne values at some altitudes and underestimated Ne values at others. The results obtained in the study showed that the observation-model differences were significant especially for the real observed (not median) data. For practical application, it is clearly important for the IRI2012 model to be adapted to the observed F2-layer peak parameters. However, the model does not offer a simple solution to predict the shape of the vertical electron density profile in the topside ionosphere, because of the problem with the topside shape parameters.
Zheng, Dong; Yuan, Xiang-Ai; Ma, Haibo; Li, Xiaoxiong; Wang, Xizhang; Liu, Ziteng
2018-01-01
Cresol is a prototype molecule in understanding intermolecular interactions in material and biological systems, because it offers different binding sites with various solvents and protonation states under different pH values. It is found that the UV/Vis absorption spectra of o-cresol in aromatic solvents (benzene, toluene) are characterized by a sharp peak, unlike the broad double-peaks in 11 non-aromatic solvents. Both molecular dynamics simulations and electronic structure calculations revealed the formation of intermolecular π-complexation between o-cresol and aromatic solvents. The thermal movements of solvent and solute molecules render the conformations of o-cresol changing between trans and cis isomers. The π-interaction makes the cis configuration a dominant isomer, hence leading to the single keen-edged UV/Vis absorption peak at approximately 283 nm. The free conformation changes between trans and cis in aqueous solution rationalize the broader absorption peaks in the range of 260–280 nm. The pH dependence of the UV/Vis absorption spectra in aqueous solutions is also rationalized by different protonation states of o-cresol. The explicit solvent model with long-ranged interactions is vital to describe the effects of π-complexation and electrostatic interaction on the UV/Vis absorption spectra of o-cresol in toluene and alkaline aqueous (pH > 10.3) solutions, respectively. PMID:29657794
Zheng, Dong; Yuan, Xiang-Ai; Ma, Haibo; Li, Xiaoxiong; Wang, Xizhang; Liu, Ziteng; Ma, Jing
2018-03-01
Cresol is a prototype molecule in understanding intermolecular interactions in material and biological systems, because it offers different binding sites with various solvents and protonation states under different pH values. It is found that the UV/Vis absorption spectra of o -cresol in aromatic solvents (benzene, toluene) are characterized by a sharp peak, unlike the broad double-peaks in 11 non-aromatic solvents. Both molecular dynamics simulations and electronic structure calculations revealed the formation of intermolecular π-complexation between o -cresol and aromatic solvents. The thermal movements of solvent and solute molecules render the conformations of o -cresol changing between trans and cis isomers. The π-interaction makes the cis configuration a dominant isomer, hence leading to the single keen-edged UV/Vis absorption peak at approximately 283 nm. The free conformation changes between trans and cis in aqueous solution rationalize the broader absorption peaks in the range of 260-280 nm. The pH dependence of the UV/Vis absorption spectra in aqueous solutions is also rationalized by different protonation states of o -cresol. The explicit solvent model with long-ranged interactions is vital to describe the effects of π-complexation and electrostatic interaction on the UV/Vis absorption spectra of o -cresol in toluene and alkaline aqueous (pH > 10.3) solutions, respectively.
NASA Astrophysics Data System (ADS)
Baribeau, J.-M.; Lockwood, D. J.; Syme, R. W. G.
1996-08-01
We have used x-ray diffraction, specular reflectivity, and diffuse scattering, complemented by Raman spectroscopy, to study the interfaces in a series of (0.5 nm Ge/2 nm Si)50 atomic layer superlattices on (001)Si grown by molecular beam epitaxy in the temperature range 150-650 °C. X-ray specular reflectivity revealed that the structures have a well-defined periodicity with interface widths of about 0.2-0.3 nm in the 300-590 °C temperature range. Offset reflectivity scans showed that the diffuse scattering peaks at values of perpendicular wave vector transfer corresponding to the superlattice satellite peaks, indicating that the interfaces are vertically correlated. Transverse rocking scans of satellite peaks showed a diffuse component corresponding to an interface corrugation of typical length scale of ˜0.5 μm. The wavelength of the undulations is a minimum along the miscut direction and is typically 30-40 times larger than the surface average terrace width assuming monolayer steps, independently of the magnitude of the wafer misorientation. The amplitude of the undulation evolves with growth temperature and is minimum for growth at ˜460 °C and peaks at ˜520 °C. Raman scattering showed the chemical abruptness of the interfaces at low growth temperatures and indicated a change in the growth mode near 450 °C.
NASA Astrophysics Data System (ADS)
Singh, Ranjit; Kainth, Harpreet Singh
2018-07-01
The luminiscence characteristics of thermoluminscence dosimeter LiF: Mg, Ti (TLD-100) irradiated to X-rays from 6 MV linac have been studied for wide range of 2-50 K/s readout linear heating rates. The reproducibility of glow curves for TLDs is found to be better at lower heating rates and depreciate at higher heating rates. The glow curve spectra were analysed using deconvolution procedure based on general-order kinetics. Shift in the peak maximum temperature per unit rise in heating rate for various peaks were found to decrease with heating rate. The TLDs irradiated with same dose exhibit decreasing TL counts with increase in the heating rate, which indicate the thermal quenching effect in TLD-100. The value of activation energy for each peak within the glow curve increases with heating rate. Calibration curves plotted for the dose range 0.4-1020 cGy exhibit decreasing slope with increasing readout heating rate. Corrections for temperature lag between the heating element and the dosimeter, and the effective heating rate (βeff) across the sample estimated using formulation proposed by Kitis and Tuyn and are found to be fairly applicable.
NASA Astrophysics Data System (ADS)
La Rosa, Vanessa; Kacperek, Andrzej; Royle, Gary; Gibson, Adam
2014-06-01
Metal fiducial markers are often implanted on the back of the eye before proton therapy to improve target localization and reduce patient setup errors. We aim to detect characteristic x-ray emissions from metal targets during proton therapy to verify the treatment range accuracy. Initially gold was chosen for its biocompatibility properties. Proton-induced x-ray emissions (PIXE) from a 15 mm diameter gold marker were detected at different penetration depths of a 59 MeV proton beam at the CATANA proton facility at INFN-LNS (Italy). The Monte Carlo code Geant4 was used to reproduce the experiment and to investigate the effect of different size markers, materials, and the response to both mono-energetic and fully modulated beams. The intensity of the emitted x-rays decreases with decreasing proton energy and thus decreases with depth. If we assume the range to be the depth at which the dose is reduced to 10% of its maximum value and we define the residual range as the distance between the marker and the range of the beam, then the minimum residual range which can be detected with 95% confidence level is the depth at which the PIXE peak is equal to 1.96 σbkg, which is the standard variation of the background noise. With our system and experimental setup this value is 3 mm, when 20 GyE are delivered to a gold marker of 15 mm diameter. Results from silver are more promising. Even when a 5 mm diameter silver marker is placed at a depth equal to the range, the PIXE peak is 2.1 σbkg. Although these quantitative results are dependent on the experimental setup used in this research study, they demonstrate that the real-time analysis of the PIXE emitted by fiducial metal markers can be used to derive beam range. Further analysis are needed to demonstrate the feasibility of the technique in a clinical setup.
Time-varying value of electric energy efficiency
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mims, Natalie A.; Eckman, Tom; Goldman, Charles
Electric energy efficiency resources save energy and may reduce peak demand. Historically, quantification of energy efficiency benefits has largely focused on the economic value of energy savings during the first year and lifetime of the installed measures. Due in part to the lack of publicly available research on end-use load shapes (i.e., the hourly or seasonal timing of electricity savings) and energy savings shapes, consideration of the impact of energy efficiency on peak demand reduction (i.e., capacity savings) has been more limited. End-use load research and the hourly valuation of efficiency savings are used for a variety of electricity planningmore » functions, including load forecasting, demand-side management and evaluation, capacity and demand response planning, long-term resource planning, renewable energy integration, assessing potential grid modernization investments, establishing rates and pricing, and customer service. This study reviews existing literature on the time-varying value of energy efficiency savings, provides examples in four geographically diverse locations of how consideration of the time-varying value of efficiency savings impacts the calculation of power system benefits, and identifies future research needs to enhance the consideration of the time-varying value of energy efficiency in cost-effectiveness screening analysis. Findings from this study include: -The time-varying value of individual energy efficiency measures varies across the locations studied because of the physical and operational characteristics of the individual utility system (e.g., summer or winter peaking, load factor, reserve margin) as well as the time periods during which savings from measures occur. -Across the four locations studied, some of the largest capacity benefits from energy efficiency are derived from the deferral of transmission and distribution system infrastructure upgrades. However, the deferred cost of such upgrades also exhibited the greatest range in value of all the components of avoided costs across the locations studied. -Of the five energy efficiency measures studied, those targeting residential air conditioning in summer-peaking electric systems have the most significant added value when the total time-varying value is considered. -The increased use of rooftop solar systems, storage, and demand response, and the addition of electric vehicles and other major new electricity-consuming end uses are anticipated to significantly alter the load shape of many utility systems in the future. Data used to estimate the impact of energy efficiency measures on electric system peak demands will need to be updated periodically to accurately reflect the value of savings as system load shapes change. -Publicly available components of electric system costs avoided through energy efficiency are not uniform across states and utilities. Inclusion or exclusion of these components and differences in their value affect estimates of the time-varying value of energy efficiency. -Publicly available data on end-use load and energy savings shapes are limited, are concentrated regionally, and should be expanded.« less
Short latency compound action potentials from mammalian gravity receptor organs
NASA Technical Reports Server (NTRS)
Jones, T. A.; Jones, S. M.
1999-01-01
Gravity receptor function was characterized in four mammalian species using far-field vestibular evoked potentials (VsEPs). VsEPs are compound action potentials of the vestibular nerve and central relays that are elicited by linear acceleration ramps applied to the cranium. Rats, mice, guinea pigs, and gerbils were studied. In all species, response onset occurred within 1.5 ms of the stimulus onset. Responses persisted during intense (116 dBSPL) wide-band (50 to 50 inverted question mark omitted inverted question mark000 Hz) forward masking, whereas auditory responses to intense clicks (112 dBpeSPL) were eliminated under the same conditions. VsEPs remained after cochlear extirpation but were eliminated following bilateral labyrinthectomy. Responses included a series of positive and negative peaks that occurred within 8 ms of stimulus onset (range of means at +6 dBre: 1.0 g/ms: P1=908 to 1062 micros, N1=1342 to 1475 micros, P2=1632 to 1952 micros, N2=2038 to 2387 micros). Mean response amplitudes at +6 dBre: 1.0 g/ms ranged from 0.14 to 0.99 microV. VsEP input/output functions revealed latency slopes that varied across peaks and species ranging from -19 to -51 micros/dB. Amplitude-intensity slopes also varied ranging from 0.04 to 0.08 microV/dB for rats and mice. Latency values were comparable to those of birds although amplitudes were substantially smaller in mammals. VsEP threshold values were considerably higher in mammals compared to birds and ranged from -8.1 to -10.5 dBre 1.0 g/ms across species. These results support the hypothesis that mammalian gravity receptors are less sensitive to dynamic stimuli than are those of birds.
Golman, Mikhail; Padovano, William; Shmuylovich, Leonid; Kovács, Sándor J
2018-03-01
Conventional echocardiographic diastolic function (DF) assessment approximates transmitral flow velocity contours (Doppler E-waves) as triangles, with peak (E peak ), acceleration time (AT), and deceleration time (DT) as indexes. These metrics have limited value because they are unable to characterize the underlying physiology. The parametrized diastolic filling (PDF) formalism provides a physiologic, kinematic mechanism based characterization of DF by extracting chamber stiffness (k), relaxation (c), and load (x o ) from E-wave contours. We derive the mathematical relationship between the PDF parameters and E peak , AT, DT and thereby introduce the geometric method (GM) that computes the PDF parameters using E peak , AT, and DT as input. Numerical experiments validated GM by analysis of 208 E-waves from 31 datasets spanning the full range of clinical diastolic function. GM yielded indistinguishable average parameter values per subject vs. the gold-standard PDF method (k: R 2 = 0.94, c: R 2 = 0.95, x o : R 2 = 0.95, p < 0.01 all parameters). Additionally, inter-rater reliability for GM-determined parameters was excellent (k: ICC = 0.956 c: ICC = 0.944, x o : ICC = 0.993). Results indicate that E-wave symmetry (AT/DT) may comprise a new index of DF. By employing indexes (E peak , AT, DT) that are already in standard clinical use the GM capitalizes on the power of the PDF method to quantify DF in terms of physiologic chamber properties.
Humboldt's spa: microbial diversity is controlled by temperature in geothermal environments
Sharp, Christine E; Brady, Allyson L; Sharp, Glen H; Grasby, Stephen E; Stott, Matthew B; Dunfield, Peter F
2014-01-01
Over 200 years ago Alexander von Humboldt (1808) observed that plant and animal diversity peaks at tropical latitudes and decreases toward the poles, a trend he attributed to more favorable temperatures in the tropics. Studies to date suggest that this temperature–diversity gradient is weak or nonexistent for Bacteria and Archaea. To test the impacts of temperature as well as pH on bacterial and archaeal diversity, we performed pyrotag sequencing of 16S rRNA genes retrieved from 165 soil, sediment and biomat samples of 36 geothermal areas in Canada and New Zealand, covering a temperature range of 7.5–99 °C and a pH range of 1.8–9.0. This represents the widest ranges of temperature and pH yet examined in a single microbial diversity study. Species richness and diversity indices were strongly correlated to temperature, with R2 values up to 0.62 for neutral–alkaline springs. The distributions were unimodal, with peak diversity at 24 °C and decreasing diversity at higher and lower temperature extremes. There was also a significant pH effect on diversity; however, in contrast to previous studies of soil microbial diversity, pH explained less of the variability (13–20%) than temperature in the geothermal samples. No correlation was observed between diversity values and latitude from the equator, and we therefore infer a direct temperature effect in our data set. These results demonstrate that temperature exerts a strong control on microbial diversity when considered over most of the temperature range within which life is possible. PMID:24430481
Antonovic, L; Brahme, A; Furusawa, Y; Toma-Dasu, I
2013-01-01
Light-ion radiation therapy against hypoxic tumors is highly curative due to reduced dependence on the presence of oxygen in the tumor at elevated linear energy transfer (LET) towards the Bragg peak. Clinical ion beams using spread-out Bragg peak (SOBP) are characterized by a wide spectrum of LET values. Accurate treatment optimization requires a method that can account for influence of the variation in response for a broad range of tumor hypoxia, absorbed doses and LETs. This paper presents a parameterization of the Repairable Conditionally-Repairable (RCR) cell survival model that can describe the survival of oxic and hypoxic cells over a wide range of LET values, and investigates the relationship between hypoxic radiation resistance and LET. The biological response model was tested by fitting cell survival data under oxic and anoxic conditions for V79 cells irradiated with LETs within the range of 30-500 keV/µm. The model provides good agreement with experimental cell survival data for the range of LET investigated, confirming the robustness of the parameterization method. This new version of the RCR model is suitable for describing the biological response of mixed populations of oxic and hypoxic cells and at the same time taking into account the distribution of doses and LETs in the incident beam and its variation with depth in tissue. The model offers a versatile tool for the selection of LET and dose required in the optimization of the therapeutic effect, without severely affecting normal tissue in realistic tumors presenting highly heterogeneous oxic and hypoxic regions.
Humboldt's spa: microbial diversity is controlled by temperature in geothermal environments.
Sharp, Christine E; Brady, Allyson L; Sharp, Glen H; Grasby, Stephen E; Stott, Matthew B; Dunfield, Peter F
2014-06-01
Over 200 years ago Alexander von Humboldt (1808) observed that plant and animal diversity peaks at tropical latitudes and decreases toward the poles, a trend he attributed to more favorable temperatures in the tropics. Studies to date suggest that this temperature-diversity gradient is weak or nonexistent for Bacteria and Archaea. To test the impacts of temperature as well as pH on bacterial and archaeal diversity, we performed pyrotag sequencing of 16S rRNA genes retrieved from 165 soil, sediment and biomat samples of 36 geothermal areas in Canada and New Zealand, covering a temperature range of 7.5-99 °C and a pH range of 1.8-9.0. This represents the widest ranges of temperature and pH yet examined in a single microbial diversity study. Species richness and diversity indices were strongly correlated to temperature, with R(2) values up to 0.62 for neutral-alkaline springs. The distributions were unimodal, with peak diversity at 24 °C and decreasing diversity at higher and lower temperature extremes. There was also a significant pH effect on diversity; however, in contrast to previous studies of soil microbial diversity, pH explained less of the variability (13-20%) than temperature in the geothermal samples. No correlation was observed between diversity values and latitude from the equator, and we therefore infer a direct temperature effect in our data set. These results demonstrate that temperature exerts a strong control on microbial diversity when considered over most of the temperature range within which life is possible.
NASA Astrophysics Data System (ADS)
Doctor, D. H.; Sebestyen, S. D.; Aiken, G. R.; Shanley, J. B.; Kendall, C.; Boyer, E. W.
2006-12-01
Increased DOC flux in streams and rivers is commonly observed during high runoff regimes, however DOC concentrations alone do not provide information about multiple sources or pathways of DOC to streams. In an effort to gain this information, we measured DOC concentrations and stable carbon isotope composition (δ13C-DOC) on samples collected at high-frequency during events at Sleepers River Research Watershed in Vermont, USA. During snowmelt and storm events, peaks in stream DOC concentration (up to 10.5 mg/L) were coincident with peaks in flow. Stream water δ13C-DOC measurements ranged between -23.7‰ and - 28.9‰ and indicated changing sources of DOC during events; the highest δ13C-DOC values occurred consistently at the lowest flows, and the lowest δ13C-DOC values occurred with peaks in discharge. Water samples collected from shallow wells and stacked soil lysimeters showed the highest DOC concentrations in the most shallow (<0.5 m) lysimeter waters, and the lowest concentrations in the deeper (>1.5 m) well waters. Wells and lysimeters exhibited a range of δ13C-DOC values similar to those observed in the stream; however, samples collected from shallow horizons at nested wells and lysimeters consistently showed lower δ13C-DOC values than those from greater depths. Maple leaf litter collected from across the watershed provided an end-member of fresh organic material, with average δ13C composition of -31.3±0.7‰ (n=57), which is lower than the lowest measured DOC values in any of the stream, well, or lysimeter waters. A subset of stream waters were fractionated onto XAD4 and XAD8 resins; the hydrophobic acid fraction (XAD8) had consistently lower δ13C values than the transphilic acid fraction (XAD4), and both of these were lower than those of the bulk DOC. Samples with lower δ13C-DOC values also exhibited higher SUVA-254 values, i.e. greater aromaticity. Thus, lower δ13C-DOC values are interpreted as an indicator of relatively "fresh", more aromatic and more biologically labile material while higher δ13C-DOC values indicate relatively more degraded material. Since lower δ13C-DOC values were observed in the shallowest well and lysimeter waters and in stream water during periods of highest DOC flux, we surmise that fresh DOC is mobilized to the stream along relatively shallow flowpaths during high flows, and that a second source of more degraded DOC supplies background concentrations to the stream at lower flows.
NASA Technical Reports Server (NTRS)
Cruz, Juan R.; Way, David W.; Shidner, Jeremy D.; Davis, Jody L.; Adams, Douglas S.; Kipp, Devin M.
2013-01-01
The Mars Science Laboratory used a single mortar-deployed disk-gap-band parachute of 21.35 m nominal diameter to assist in the landing of the Curiosity rover on the surface of Mars. The parachute system s performance on Mars has been reconstructed using data from the on-board inertial measurement unit, atmospheric models, and terrestrial measurements of the parachute system. In addition, the parachute performance results were compared against the end-to-end entry, descent, and landing (EDL) simulation created to design, develop, and operate the EDL system. Mortar performance was nominal. The time from mortar fire to suspension lines stretch (deployment) was 1.135 s, and the time from suspension lines stretch to first peak force (inflation) was 0.635 s. These times were slightly shorter than those used in the simulation. The reconstructed aerodynamic portion of the first peak force was 153.8 kN; the median value for this parameter from an 8,000-trial Monte Carlo simulation yielded a value of 175.4 kN - 14% higher than the reconstructed value. Aeroshell dynamics during the parachute phase of EDL were evaluated by examining the aeroshell rotation rate and rotational acceleration. The peak values of these parameters were 69.4 deg/s and 625 deg/sq s, respectively, which were well within the acceptable range. The EDL simulation was successful in predicting the aeroshell dynamics within reasonable bounds. The average total parachute force coefficient for Mach numbers below 0.6 was 0.624, which is close to the pre-flight model nominal drag coefficient of 0.615.
NASA Astrophysics Data System (ADS)
Santos, Sílvia; Cardoso, Joana F. M. F.; Carvalho, Célia; Luttikhuizen, Pieternella C.; van der Veer, Henk W.
2011-03-01
Monthly investment in soma and gonads in the bivalve Scrobicularia plana is described for three populations along its distributional range: Minho estuary, Portugal; Westerschelde estuary, The Netherlands and Buvika estuary, Norway. Seasonal cycles in body mass (BMI), somatic mass (SMI) and gonadal mass (GMI) indices were observed for all populations. In Portugal, BMI and SMI peaked in mid-autumn, while in The Netherlands both indices were at their highest in mid-spring. Norway showed a different pattern with two distinct peaks: one in mid-autumn and a second peak in spring. GMI reached maximum values in July in Portugal and Netherlands and in June in Norway. Overall, mean BMI and SMI were lower in Portugal while mean GMI was lower in Norway. The spawning period lasted the whole summer in Portugal, but was shorter (only two months) in The Netherlands and Norway. The reproductive investment in The Netherlands was significantly higher than in Portugal and Norway, with the lowest values being observed in Norway. Differences in annual cycles between populations were attributed to environmental factors, namely temperature and food availability. Temperature seems important in shaping the reproductive pattern with more northern populations showing shorter reproductive periods starting later in the year, and a lower reproductive output. In addition, winter water temperatures can explain the lower mean body and somatic mass values observed in Portugal. Food availability influenced the physiological performance of the species with peaks in somatic mass coinciding with phytoplankton blooms. This relation between physiological performance and environmental factors influences S. plana distribution, densities and even survival, with natural consequences on its commercial importance.
On the Use of Topside RO-Derived Electron Density for Model Validation
NASA Astrophysics Data System (ADS)
Shaikh, M. M.; Nava, B.; Haralambous, H.
2018-05-01
In this work, the standard Abel inversion has been exploited as a powerful observation tool, which may be helpful to model the topside of the ionosphere and therefore to validate ionospheric models. A thorough investigation on the behavior of radio occultation (RO)-derived topside electron density (Ne(h))-profiles has therefore been performed with the main purpose to understand whether it is possible to predict the accuracy of a single RO-retrieved topside by comparing the peak density and height of the retrieved profile to the true values. As a first step, a simulation study based on the use of the NeQuick2 model has been performed to show that when the RO-derived electron density peak and height match the true peak values, the full topside Ne(h)-profile may be considered accurate. In order to validate this hypothesis with experimental data, electron density profiles obtained from four different incoherent scatter radars have therefore been considered together with co-located RO-derived Ne(h)-profiles. The evidence presented in this paper show that in all cases examined, if the incoherent scatter radar and the corresponding co-located RO profile have matching peak parameter values, their topsides are in very good agreement. The simulation results presented in this work also highlighted the importance of considering the occultation plane azimuth while inverting RO data to obtain Ne(h)-profile. In particular, they have indicated that there is a preferred range of azimuths of the occultation plane (80°-100°) for which the difference between the "true" and the RO-retrieved Ne(h)-profile in the topside is generally minimal.
Palacios‐López, Adalberto; Humberto Prieto‐Benavides, Daniel; Enrique Correa‐Bautista, Jorge; Izquierdo, Mikel; Alonso‐Martínez, Alicia; Lobelo, Felipe
2016-01-01
Abstract Objectives Our aim was to determine the normative reference values of cardiorespiratory fitness (CRF) and to establish the proportion of subjects with low CRF suggestive of future cardio‐metabolic risk. Methods A total of 7244 children and adolescents attending public schools in Bogota, Colombia (55.7% girls; age range of 9–17.9 years) participated in this study. We expressed CRF performance as the nearest stage (minute) completed and the estimated peak oxygen consumption (V˙O2peak). Smoothed percentile curves were calculated. In addition, we present the prevalence of low CRF after applying a correction factor to account for the impact of Bogota's altitude (2625 m over sea level) on CRF assessment, and we calculated the number of participants who fell below health‐related FITNESSGRAM cut‐points for low CRF. Results Shuttles and V˙O2peak were higher in boys than in girls in all age groups. In boys, there were higher levels of performance with increasing age, with most gains between the ages of 13 and 17. The proportion of subjects with a low CRF, suggestive of future cardio‐metabolic risk (health risk FITNESSGRAM category) was 31.5% (28.2% for boys and 34.1% for girls; X2 P = .001). After applying a 1.11 altitude correction factor, the overall prevalence of low CRF was 11.5% (9.6% for boys and 13.1% for girls; X2 P = .001). Conclusions Our results provide sex‐ and age‐specific normative reference standards for the 20 m shuttle‐run test and estimated V˙O2peak values in a large, population‐based sample of schoolchildren from a large Latin‐American city at high altitude. PMID:27500986
Kinetics of phase transformations in glass forming systems
NASA Technical Reports Server (NTRS)
Ray, Chandra S.
1993-01-01
In crystallization measurements of nonisothermal nucleation for Li2O.2SiO2 (LS2) glass, using DTA, the glass sample is scanned at different constant heating rates until it is crystallized. This means that the temperature range where nucleation can occur for the glass is scanned also at different rates which allows the glass to be nucleated for different time prior to crystallization. Consequently, the concentration of nuclei developed in the glass may be different for different heating rates and the DTA peak height which has shown to be sensitive to the number of nuclei present in the sample, is expected to change with heating rate. DTA peak height depends strongly on the overlap between the nucleation rate and growth rate curves, assuming the peak height is directly proportional to the total number of nuclei present in the glass sample under investigation, which, in turn, should be proportional to the volume or weight of the sample. To verify this assumption, DTA measurements were made using a LS2 glass to determine the peak height as a function of the sample weight. Using the DTA peak height technique, a nucleation rate like curve was determined for the BaO.2SiO2 (BS2) glass which showed that the temperature for nucleation ranged from 650 to 750 C for this glass and the temperature for maximum nucleation was approximately 705 C. These values are in excellent agreement with those determined by the conventional technique. There was international collaboration with Japan and Germany on this project.
Accurate determinations of one-bond 13C-13C couplings in 13C-labeled carbohydrates
NASA Astrophysics Data System (ADS)
Azurmendi, Hugo F.; Freedberg, Darón I.
2013-03-01
Carbon plays a central role in the molecular architecture of carbohydrates, yet the availability of accurate methods for 1DCC determination has not been sufficiently explored, despite the importance that such data could play in structural studies of oligo- and polysaccharides. Existing methods require fitting intensity ratios of cross- to diagonal-peaks as a function of the constant-time (CT) in CT-COSY experiments, while other methods utilize measurement of peak separation. The former strategies suffer from complications due to peak overlap, primarily in regions close to the diagonal, while the latter strategies are negatively impacted by the common occurrence of strong coupling in sugars, which requires a reliable assessment of their influence in the context of RDC determination. We detail a 13C-13C CT-COSY method that combines a variation in the CT processed with diagonal filtering to yield 1JCC and RDCs. The strategy, which relies solely on cross-peak intensity modulation, is inspired in the cross-peak nulling method used for JHH determinations, but adapted and extended to applications where, like in sugars, large one-bond 13C-13C couplings coexist with relatively small long-range couplings. Because diagonal peaks are not utilized, overlap problems are greatly alleviated. Thus, one-bond couplings can be determined from different cross-peaks as either active or passive coupling. This results in increased accuracy when more than one determination is available, and in more opportunities to measure a specific coupling in the presence of severe overlap. In addition, we evaluate the influence of strong couplings on the determination of RDCs by computer simulations. We show that individual scalar couplings are notably affected by the presence of strong couplings but, at least for the simple cases studied, the obtained RDC values for use in structural calculations were not, because the errors introduced by strong couplings for the isotropic and oriented phases are very similar and therefore cancel when calculating the difference to determine 1DCC values.
A search for evidence of solar rotation in Super-Kamiokande solar neutrino dataset
NASA Astrophysics Data System (ADS)
Desai, Shantanu; Liu, Dawei W.
2016-09-01
We apply the generalized Lomb-Scargle (LS) periodogram, proposed by Zechmeister and Kurster, to the solar neutrino data from Super-Kamiokande (Super-K) using data from its first five years. For each peak in the LS periodogram, we evaluate the statistical significance in two different ways. The first method involves calculating the False Alarm Probability (FAP) using non-parametric bootstrap resampling, and the second method is by calculating the difference in Bayesian Information Criterion (BIC) between the null hypothesis, viz. the data contains only noise, compared to the hypothesis that the data contains a peak at a given frequency. Using these methods, we scan the frequency range between 7-14 cycles per year to look for any peaks caused by solar rotation, since this is the proposed explanation for the statistically significant peaks found by Sturrock and collaborators in the Super-K dataset. From our analysis, we do confirm that similar to Sturrock et al, the maximum peak occurs at a frequency of 9.42/year, corresponding to a period of 38.75 days. The FAP for this peak is about 1.5% and the difference in BIC (between pure white noise and this peak) is about 4.8. We note that the significance depends on the frequency band used to search for peaks and hence it is important to use a search band appropriate for solar rotation. However, The significance of this peak based on the value of BIC is marginal and more data is needed to confirm if the peak persists and is real.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mandage, Revati S.; McAteer, R. T. James, E-mail: mcateer@nmsu.edu
A magnetic power spectral analysis is performed on 53 solar active regions, observed from 2011 August to 2012 July. Magnetic field data obtained from the Helioseismic and Magnetic Imager, inverted as Active Region Patches, are used to study the evolution of the magnetic power index as each region rotates across the solar disk. Active regions are classified based on the numbers and sizes of solar flares they produce in order to study the relationship between flare productivity and the magnetic power index. The choice of window size and inertial range plays a key role in determining the correct magnetic powermore » index. The overall distribution of magnetic power indices has a range of 1.0–2.5. Flare-quiet regions peak at a value of 1.6. However, flare-productive regions peak at a value of 2.2. Overall, the histogram of the distribution of power indices of flare-productive active regions is well separated from flare-quiet active regions. Only 12% of flare-quiet regions exhibit an index greater than 2, whereas 90% of flare-productive regions exhibit an index greater than 2. Flare-quiet regions exhibit a high temporal variance (i.e., the index fluctuates between high and low values), whereas flare-productive regions maintain an index greater than 2 for several days. This shows the importance of including the temporal evolution of active regions in flare prediction studies, and highlights the potential of a 2–3 day prediction window for space weather applications.« less
Shin, Yong Beom; Kim, Seong-Jang; Kim, In-Ju; Kim, Yong-Ki; Kim, Dong-Soo; Park, Jae Heung; Yeom, Seok-Ran
2006-06-01
Statistical parametric mapping (SPM) was applied to brain perfusion single photon emission computed tomography (SPECT) images in patients with traumatic brain injury (TBI) to investigate regional cerebral abnormalities compared to age-matched normal controls. Thirteen patients with TBI underwent brain perfusion SPECT were included in this study (10 males, three females, mean age 39.8 +/- 18.2, range 21 - 74). SPM2 software implemented in MATLAB 5.3 was used for spatial pre-processing and analysis and to determine the quantitative differences between TBI patients and age-matched normal controls. Three large voxel clusters of significantly decreased cerebral blood perfusion were found in patients with TBI. The largest clusters were area including medial frontal gyrus (voxel number 3642, peak Z-value = 4.31, 4.27, p = 0.000) in both hemispheres. The second largest clusters were areas including cingulated gyrus and anterior cingulate gyrus of left hemisphere (voxel number 381, peak Z-value = 3.67, 3.62, p = 0.000). Other clusters were parahippocampal gyrus (voxel number 173, peak Z-value = 3.40, p = 0.000) and hippocampus (voxel number 173, peak Z-value = 3.23, p = 0.001) in the left hemisphere. The false discovery rate (FDR) was less than 0.04. From this study, group and individual analyses of SPM2 could clearly identify the perfusion abnormalities of brain SPECT in patients with TBI. Group analysis of SPM2 showed hypoperfusion pattern in the areas including medial frontal gyrus of both hemispheres, cingulate gyrus, anterior cingulate gyrus, parahippocampal gyrus and hippocampus in the left hemisphere compared to age-matched normal controls. Also, left parahippocampal gyrus and left hippocampus were additional hypoperfusion areas. However, these findings deserve further investigation on a larger number of patients to be performed to allow a better validation of objective SPM analysis in patients with TBI.
NASA Technical Reports Server (NTRS)
Rodriguez, A.; Alpen, E. L.; Powers-Risius, P.
1992-01-01
This report presents data for survival of mouse intestinal crypt cells, mouse testes weight loss as an indicator of survival of spermatogonial stem cells, and survival of rat 9L spheroid cells after irradiation in the plateau region of unmodified particle beams ranging in mass from 4He to 139La. The LET values range from 1.6 to 953 keV/microns. These studies examine the RBE-LET relationship for two normal tissues and for an in vitro tissue model, multicellular spheroids. When the RBE values are plotted as a function of LET, the resulting curve is characterized by a region in which RBE increases with LET, a peak RBE at an LET value of 100 keV/microns, and a region of decreasing RBE at LETs greater than 100 keV/microns. Inactivation cross sections (sigma) for these three biological systems have been calculated from the exponential terminal slope of the dose-response relationship for each ion. For this determination the dose is expressed as particle fluence and the parameter sigma indicates effect per particle. A plot of sigma versus LET shows that the curve for testes weight loss is shifted to the left, indicating greater radiosensitivity at lower LETs than for crypt cell and spheroid cell survival. The curves for cross section versus LET for all three model systems show similar characteristics with a relatively linear portion below 100 keV/microns and a region of lessened slope in the LET range above 100 keV/microns for testes and spheroids. The data indicate that the effectiveness per particle increases as a function of LET and, to a limited extent, Z, at LET values greater than 100 keV/microns. Previously published results for spread Bragg peaks are also summarized, and they suggest that RBE is dependent on both the LET and the Z of the particle.
Knauert, Melissa; Jeon, Sangchoon; Murphy, Terrence E.; Yaggi, H. Klar; Pisani, Margaret A.; Redeker, Nancy S.
2016-01-01
Purpose Sound levels in the intensive care unit (ICU) are universally elevated and are believed to contribute to sleep and circadian disruption. The purpose of this study is to compare overnight ICU sound levels and peak occurrence on A- versus C-weighted scales. Materials and Methods This was a prospective observational study of overnight sound levels in 59 medical ICU patient rooms. Sound level was recorded every 10 seconds on A- and C-weighted decibel scales. Equivalent sound level (Leq) and sound peaks were reported for full and partial night periods. Results The overnight A-weighted Leq of 53.6 dBA was well above World Health Organization (WHO) recommendations; overnight C-weighted Leq was 63.1 dBC (no WHO recommendations). Peak sound occurrence ranged from 1.8 to 23.3 times per hour. Illness severity, mechanical ventilation and delirium were not associated with Leq or peak occurrence. Leq and peak measures for A- and C-weighted decibel scales were significantly different from each other. Conclusions Sound levels in the medical ICU are high throughout the night. Patient factors were not associated with Leq or peak occurrence. Significant discordance between A- and C-weighted values suggests that low frequency sound is a meaningful factor in the medical ICU environment. PMID:27546739
NASA Astrophysics Data System (ADS)
Saleem Mirza, Muhammad; Yasin, Tariq; Ikram, Masroor; Altaf, Muhammad; Mushtaq, Zahir; Nasir Khan, Muhammad
2016-03-01
Underwater characterizations of (Pb0.94Sr0.04)(Zr0.52Ti0.48)O3 (PZT) and PZT/araldite-F 1-3 composite were carried out through a self-designed transducer. Disc-shaped samples of bulk PZT and PZT/araldite-F composite were first characterized in air and then were assembled in the transducer individually. The transducer's underwater voltage receiving sensitivity (Sh) and transmitting voltage response (Sv) were investigated in the frequency range of 10-200 kHz (well below thickness mode resonance) using a calibrated projector and receiver method with pulse technique. Results revealed that the transducer made with composite sample exhibited better (Sh) values (-214 dB ref 1 V/µPa) due to ~295% higher piezoelectric voltage coefficient gh (30 × 10-3 Vm/N) of the composite compared to PZT. In addition, the transducer with the PZT sample showed better Sv values (80 dB ref 1 µPa/1 V at 1 m) due to the presence of planar mode peaks in the frequency range of 10-200 kHz. These results indicate that the monolithic piezoceramic can exhibit underwater Sv response in both planar and thickness resonance modes owing to the admittance peaks in these frequency regions.
Ou-Yang, Li-Xue; Yang, Fan
2017-07-01
To evaluate the diagnostic value of baseline serum luteinizing hormone (LH) level for central precocious puberty (CPP) in girls. A total of 279 girls with precocious puberty were subjected to assessment of growth and development, bone age determination, baseline LH test, and follicle-stimulating hormone (FSH) test, gonadotropin-releasing hormone stimulation test, and other related examinations. Of the 279 patients, 175 were diagnosed with CPP and 104 with premature thelarche (PT). The receiver operating characteristic (ROC) curve was used to evaluate the diagnostic value of baseline LH and FSH levels and their peak levels for CPP, and the correlation between the baseline LH level and the peak LH level was analyzed. The CPP group had significantly higher bone age, baseline LH and FSH levels, peak LH and FSH levels, and ratio of peak LH level to peak FSH level than the PT group (P<0.01). The ROC curve proved that baseline LH level and peak LH level had good diagnostic values for CPP. Among the three bone age subgroups in the CPP group (7.0-9.0 years, 9.0-11.0 years, and >11.0 years), baseline LH level showed the best diagnostic value in the >11.0 years subgroup, with the largest area under the ROC curve. At a baseline LH level of 0.45 IU/L, the Youden index reached the peak value, and the sensitivity and specificity were 66.7% and 80% respectively, for the diagnosis of CPP. At a peak LH level of 9.935 IU/L, the Youden index reached the peak value, and the sensitivity and specificity were 74.8% and 100% respectively, for the diagnosis of CPP. The baseline LH level was positively correlated with the peak LH level (r=0.440, P<0.01). Baseline LH level can be used as an primary screening index for the diagnosis of CPP. It has a certain diagnostic value for CPP at different bone ages, and may be used as a monitoring index during the treatment and follow-uP.
Pulsatile flow in a compliant stenosed asymmetric model
NASA Astrophysics Data System (ADS)
Usmani, Abdullah Y.; Muralidhar, K.
2016-12-01
Time-varying velocity field in an asymmetric constricted tube is experimentally studied using a two-dimensional particle image velocimetry system. The geometry resembles a vascular disease which is characterized by arterial narrowing due to plaque deposition. The present study compares the nature of flow patterns in rigid and compliant asymmetric constricted tubes for a range of dimensionless parameters appearing in a human artery. A blood analogue fluid is employed along with a pump that mimics cardioflow conditions. The peak Reynolds number range is Re 300-800, while the Womersley number range considered in experiments is Wo 6-8. These values are based on the peak velocity in a straight rigid tube connected to the model, over a pulsation frequency range of 1.2-2.4 Hz. The medial-plane velocity distribution is used to investigate the nature of flow patterns. Temporal distribution of stream traces and hemodynamic factors including WSS, TAWSS and OSI at important phases of the pulsation cycle are discussed. The flow patterns obtained from PIV are compared to a limited extent against numerical simulation. Results show that the region downstream of the constriction is characterized by a high-velocity jet at the throat, while a recirculation zone, attached to the wall, evolves in time. Compliant models reveal large flow disturbances upstream during the retrograde flow. Wall shear stress values are lower in a compliant model as compared to the rigid. Cross-plane flow structures normal to the main flow direction are visible at select phases of the cycle. Positive values of largest Lyapunov exponent are realized for wall movement and are indicative of chaotic motion transferred from the flow to the wall. These exponents increase with Reynolds number as well as compliance. Period doubling is observed in wall displacement of highly compliant models, indicating possible triggering of hemodynamic events in a real artery that may cause fissure in the plaque deposits.
Wang, Zhong; Dell'Osso, Louis F; Jacobs, Jonathan B; Burnstine, Robert A; Tomsak, Robert L
2006-12-01
To investigate the effects of four-muscle tenotomy on visual function and gaze angle in patients with infantile nystagmus syndrome (INS). Eye movements of nine patients with infantile nystagmus were recorded using infrared reflection or high-speed digital video techniques. Experimental protocols were designed to record the patients' eye-movement waveforms, pre- and post-tenotomy, at different gaze angles. We used the eXpanded Nystagmus Acuity Function (NAFX) to measure tenotomy-induced changes in the nystagmus at primary position and various gaze angles. The longest foveation domains (LFD) were measured from fitted curves. Peak-to-peak nystagmus amplitudes and foveation-period durations were also measured. All measurements were made unmasked. All seven patients with narrow, high-NAFX, gaze-angle regions showed broadening of these regions of higher visual function. Three patients showed moderate NAFX improvement (13.9-32.6%) at primary position, five showed large improvement (39.9-162.4%), and one showed no NAFX change (due to his high pretenotomy NAFX). Primary position measured acuities improved in six patients. All patients had reductions in nystagmus amplitudes ranging from 14.6 to 37%. The duration of the foveation period increased in all nine patients (11.2-200%). The percentage improvements in both the NAFX and the LFD decreased with higher pretenotomy values. In addition to elevating primary position NAFX, tenotomy also broadens the high-NAFX regions. This broadening effect is more prominent in patients who had sharp pretenotomy NAFX peaks. Four-muscle tenotomy produces higher primary position NAFX increases in infantile nystagmus patients whose pretenotomy values are relatively low, with the improvement decreasing at higher pretenotomy values. The tenotomy procedure improves visual function beyond primary position acuity. This extends the utility of surgical therapy to several different classes of patients with INS for whom other procedures are contraindicated. The pretenotomy NAFX can now be used to predict both primary position acuity improvements and broadening of a patient's high-NAFX range of gaze angles.
NASA Astrophysics Data System (ADS)
Zhang, Xueang; Yang, Zhichao; Tang, Bin; Wang, Renbo; Wei, Xiong
2018-05-01
During geophysical surveys, water layers may interfere with the detection of oil layers. In order to distinguish between oil and water layers in porous cracked media, research on the properties of the cracks, the oil and water layers, and their relation to pulsed neutron logging characteristics is essential. Using Hudson's crack theory, we simulated oil and water layers in a cracked porous medium with different crack parameters corresponding to the well log responses. We found that, in a cracked medium with medium-angle (40°-50°) cracks, the thermal neutron count peak value is higher and more sensitive than those in low-angle and high-angle crack environments; in addition, the thermal neutron density distribution shows more minimum values than in other cases. Further, the thermal neutron count and the rate of change for the oil layer are greater than those of the water layer, and the time spectrum count peak value for the water layer in middle-high-angle (40°-70°) cracked environments is higher than that of the oil layer. The thermal neutron density distribution sensitivity is higher in the water layer with a range of small crack angles (0°-30°) than in the oil layer with the same range of angles. In comparing the thermal neutron density distribution, thermal neutron count peak, thermal neutron density distribution sensitivity, and time spectrum maximum in the oil and water layers, we find that neutrons in medium-angle (40°-50°) cracked reservoirs are more sensitive to deceleration and absorption than those in water layers; neutrons in approximately horizontal (0°-30°) cracked water layers are more sensitive to deceleration than those in reservoirs. These results can guide future work in the cracked media neutron logging field.
Kalkan, Erol; Kwong, Neal S.
2014-01-01
According to the regulatory building codes in the United States (e.g., 2010 California Building Code), at least two horizontal ground motion components are required for three-dimensional (3D) response history analysis (RHA) of building structures. For sites within 5 km of an active fault, these records should be rotated to fault-normal/fault-parallel (FN/FP) directions, and two RHAs should be performed separately (when FN and then FP are aligned with the transverse direction of the structural axes). It is assumed that this approach will lead to two sets of responses that envelope the range of possible responses over all nonredundant rotation angles. This assumption is examined here, for the first time, using a 3D computer model of a six-story reinforced-concrete instrumented building subjected to an ensemble of bidirectional near-fault ground motions. Peak values of engineering demand parameters (EDPs) were computed for rotation angles ranging from 0 through 180° to quantify the difference between peak values of EDPs over all rotation angles and those due to FN/FP direction rotated motions. It is demonstrated that rotating ground motions to FN/FP directions (1) does not always lead to the maximum responses over all angles, (2) does not always envelope the range of possible responses, and (3) does not provide maximum responses for all EDPs simultaneously even if it provides a maximum response for a specific EDP.
Athanasopoulos, Leonidas V; Dritsas, Athanasios; Doll, Helen A; Cokkinos, Dennis V
2010-08-01
This study was conducted to explain the variance in quality of life (QoL) and activity capacity of patients with congestive heart failure from pathophysiological changes as estimated by laboratory data. Peak oxygen consumption (peak VO2) and ventilation (VE)/carbon dioxide output (VCO2) slope derived from cardiopulmonary exercise testing, plasma N-terminal prohormone of B-type natriuretic peptide (NT-proBNP), and echocardiographic markers [left atrium (LA), left ventricular ejection fraction (LVEF)] were measured in 62 patients with congestive heart failure, who also completed the Minnesota Living with Heart Failure Questionnaire and the Specific Activity Questionnaire. All regression models were adjusted for age and sex. On linear regression analysis, peak VO2 with P value less than 0.001, VE/VCO2 slope with P value less than 0.01, LVEF with P value less than 0.001, LA with P=0.001, and logNT-proBNP with P value less than 0.01 were found to be associated with QoL. On stepwise multiple linear regression, peak VO2 and LVEF continued to be predictive, accounting for 40% of the variability in Minnesota Living with Heart Failure Questionnaire score. On linear regression analysis, peak VO2 with P value less than 0.001, VE/VCO2 slope with P value less than 0.001, LVEF with P value less than 0.05, LA with P value less than 0.001, and logNT-proBNP with P value less than 0.001 were found to be associated with activity capacity. On stepwise multiple linear regression, peak VO2 and LA continued to be predictive, accounting for 53% of the variability in Specific Activity Questionnaire score. Peak VO2 is independently associated both with QoL and activity capacity. In addition to peak VO2, LVEF is independently associated with QoL, and LA with activity capacity.
Amir, Rai Muhammad; Anjum, Faqir Muhammad; Khan, Muhammad Issa; Khan, Moazzam Rafiq; Pasha, Imran; Nadeem, Muhammad
2013-10-01
Quality characteristics of wheat are determined by different physiochemical and rheological analysis by using different AACC methods. AACC methods are expensive, time consuming and cause destruction of samples. Fourier transforms infrared (FTIR) spectroscopy is one of the most important and emerging tool used for analyzing wheat for different quality parameters. This technique is rapid and sensitive with a great variety of sampling techniques. In the present study different wheat varieties were analyzed for quality assessment and were also characterized by using AACC methods and FTIR technique. The straight grade flour was analyzed for physical, chemical and rheological properties by standard methods and results were obtained. FTIR works on the basis of functional groups and provide information in the form of peaks. On basis of peaks the value of moisture, protein, fat, ash, carbohydrates and hardness of grain were determined. Peaks for water were observed in the range 1,640 cm(-1) and 3,300 cm(-1) on the basis of functional group H and OH. Protein was observed in the range from 1,600 cm(-1) to 1,700 cm(-1) and 1,550 cm(-1) to 1,570 cm(-1) on the basis of bond amide I and amide II respectively. Fat was also observed within these ranges but on the basis of C-H bond and also starch was observed in the range from 2,800 and 3,000 cm(-1) (C-H stretch region) and in the range 3,000 and 3,600 cm(-1) (O-H stretch region). As FTIR is a fast tool it can be easily emplyed for wheat varieties identification according to a set criterion.
Internal combustion engine cylinder-to-cylinder balancing with balanced air-fuel ratios
Harris, Ralph E.; Bourn, Gary D.; Smalley, Anthony J.
2006-01-03
A method of balancing combustion among cylinders of an internal combustion engine. For each cylinder, a normalized peak firing pressure is calculated as the ratio of its peak firing pressure to its combustion pressure. Each cylinder's normalized peak firing pressure is compared to a target value for normalized peak firing pressure. The fuel flow is adjusted to any cylinder whose normalized peak firing pressure is not substantially equal to the target value.
Single-stage experimental evaluation of compressor blading with slots and vortex generators, part 5
NASA Technical Reports Server (NTRS)
Brent, J. A.
1972-01-01
An experimental investigation was conducted to determine the extent that slots and vortex generators can increase the efficiency and stable operating range of highly loaded compressor stages. With slots in the rotor and stator, the stage performance both with and without vortex generators was inferior to that achieved with the unslotted blading. However, with vortex generators, stator slots, and an unslotted rotor, the stable operating range increased 25% and the stage peak efficiency increased 2.1% over the values achieved with the unslotted rotor and stator without vortex generators, at design equivalent rotor speed.
NASA Technical Reports Server (NTRS)
Wu, S. T.
1985-01-01
This paper presents preliminary results of C-band radar scatterometer measurements of forest canopies of southeastern forests in the vicinity of NASA/NSTL. The results are as follows: (1) the radar backscattering coefficients (BSC) of deciduous forests such as oak, maple, blackgum, and cypress are higher than those of coniferous forests such as slash pine plantation and natural pine; (2) at a large incidence angle, where polarization effect is significant, and by ranging measurement, the VV polarization BSC obtain peak value at the first few meters from the canopy top and decrease rather quickly, while the HH polarization BSC obtain peak value at longer distances from the canopy top and decrease rather slowly through the canopy; and (3) using the active radar calibrator for tree canopy attenuation measurement of a dense and a sparse live oak, it is found that the tree canopies with higher attenuations have higher BSC for all three polarizations, with VV polarization containing the largest differential (2.2 dB).
Evaluation of fracture torque resistance of orthodontic mini-implants.
Dalla Rosa, Fernando; Burmann, Paola Fp; Ruschel, Henrique C; Vargas, Ivana A; Kramer, Paulo F
2016-12-01
This study sought to assess the fracture torque resistance of mini-implants used for orthodontic anchorage. Five commercially available brands of mini-implants were used (SIN®, CONEXÃO®, NEODENT®, MORELLI®, andFORESTADENT®). Ten mini-implants of each diameter of each brand were tested, for a total 100 specimens. The mini-implants were subject to a static torsion test as described in ASTMstandard F543. Analysis of variance (ANOVA) with the Tukey multiple comparisons procedure was used to assess results. Overall, mean fracture strength ranged from 15.7 to 70.4 N·cm. Mini-implants with larger diameter exhibited higher peak torque values at fracture and higher yield strength, regardless of brand. In addition, significant differences across brands were observed when implants were stratified by diameter. In conclusion, larger mini-implant diameter is associated with increased fracture torque resistance. Additional information on peak torque values at fracture of different commercial brands of mini-implants may increase the success rate of this orthodontic anchorage modality. Sociedad Argentina de Investigación Odontológica.
De Cock, R. F. W.; Allegaert, K.; Vanhaesebrouck, S.; Danhof, M.; Knibbe, C. A. J.
2015-01-01
Based on a previously derived population pharmacokinetic model, a novel neonatal amikacin dosing regimen was developed. The aim of the current study was to prospectively evaluate this dosing regimen. First, early (before and after second dose) therapeutic drug monitoring (TDM) observations were evaluated for achieving target trough (<3 mg/liter) and peak (>24 mg/liter) levels. Second, all observed TDM concentrations were compared with model-predicted concentrations, whereby the results of a normalized prediction distribution error (NPDE) were considered. Subsequently, Monte Carlo simulations were performed. Finally, remaining causes limiting amikacin predictability (i.e., prescription errors and disease characteristics of outliers) were explored. In 579 neonates (median birth body weight, 2,285 [range, 420 to 4,850] g; postnatal age 2 days [range, 1 to 30 days]; gestational age, 34 weeks [range, 24 to 41 weeks]), 90.5% of the observed early peak levels reached 24 mg/liter, and 60.2% of the trough levels were <3 mg/liter (93.4% ≤5 mg/liter). Observations were accurately predicted by the model without bias, which was confirmed by the NPDE. Monte Carlo simulations showed that peak concentrations of >24 mg/liter were reached at steady state in almost all patients. Trough values of <3 mg/liter at steady state were documented in 78% to 100% and 45% to 96% of simulated cases with and without ibuprofen coadministration, respectively; suboptimal trough levels were found in patients with postnatal age <14 days and current weight of >2,000 g. Prospective evaluation of a model-based neonatal amikacin dosing regimen resulted in optimized peak and trough concentrations in almost all patients. Slightly adapted dosing for patient subgroups with suboptimal trough levels was proposed. This model-based approach improves neonatal dosing individualization. PMID:26248375
Kolva, J.R.
1985-01-01
A previous study of flood magitudes and frequencies in Ohio concluded that existing regionalized flood equations may not be adequate for estimating peak flows in small basins that are heavily forested, surface mined, or located in northwestern Ohio. In order to provide a large data base for improving estimation of flood peaks in these basins, 30 crest-stage gages were installed in 1977, in cooperation with the Ohio Department of Transportation, to provide a 10-year record of flood data The study area consists of two distinct parts: Northwestern Ohio, which contains 8 sites, and southern and eastern Ohio, which contains 22 sites in small forested or surface-mined drainage basins. Basin characteristics were determined for all 30 sites for 1978 conditions. Annual peaks were recorded or estimated for all 30 sites for water years 1978-82; an additional year of peak discharges was available at four sites. The 2-year (Q2) and 5-year (Q5) flood peaks were determined from these annual peaks.Q2 and Q5 values also were calculated using published regionalized regression equations for Ohio. The ratios of the observed to predicted 2-year (R2) and 5-year (R5) values were then calculated. This study found that observed flood peaks aree lower than estimated peaks by a significant amount in surface-mined basins. The average ratios of observed to predicted R2 values are 0.51 for basins with more than 40 percent surface-minded land, and 0.68 for sites with any surface-mined land. The average R5 value is 0.55 for sites with more than 40 percent surface-minded land, and 0.61 for sites with any surface-mined land. Estimated flood peaks from forested basins agree with the observed values fairly well. R2 values average 0.87 for sites with 20 percent or more forested land, but no surface-mined land, and R5 values average 0.96. If all sites with more than 20 percent forested land and some surface-mined land are considered, R2 the values average 0.86, and the R5 values average 0.82.
Huan, Tao; Li, Liang
2015-01-20
Metabolomics requires quantitative comparison of individual metabolites present in an entire sample set. Unfortunately, missing intensity values in one or more samples are very common. Because missing values can have a profound influence on metabolomic results, the extent of missing values found in a metabolomic data set should be treated as an important parameter for measuring the analytical performance of a technique. In this work, we report a study on the scope of missing values and a robust method of filling the missing values in a chemical isotope labeling (CIL) LC-MS metabolomics platform. Unlike conventional LC-MS, CIL LC-MS quantifies the concentration differences of individual metabolites in two comparative samples based on the mass spectral peak intensity ratio of a peak pair from a mixture of differentially labeled samples. We show that this peak-pair feature can be explored as a unique means of extracting metabolite intensity information from raw mass spectra. In our approach, a peak-pair peaking algorithm, IsoMS, is initially used to process the LC-MS data set to generate a CSV file or table that contains metabolite ID and peak ratio information (i.e., metabolite-intensity table). A zero-fill program, freely available from MyCompoundID.org , is developed to automatically find a missing value in the CSV file and go back to the raw LC-MS data to find the peak pair and, then, calculate the intensity ratio and enter the ratio value into the table. Most of the missing values are found to be low abundance peak pairs. We demonstrate the performance of this method in analyzing an experimental and technical replicate data set of human urine metabolome. Furthermore, we propose a standardized approach of counting missing values in a replicate data set as a way of gauging the extent of missing values in a metabolomics platform. Finally, we illustrate that applying the zero-fill program, in conjunction with dansylation CIL LC-MS, can lead to a marked improvement in finding significant metabolites that differentiate bladder cancer patients and their controls in a metabolomics study of 109 subjects.
Simultaneous Planck, Swift, and Fermi Observations of X-ray and Gamma-ray Selected Blazars
NASA Technical Reports Server (NTRS)
Giommi, P.; Polenta, G.; Laehteenmaeki, A.; Thompson, D. J.; Capalbi, M.; Cutini, S.; Gasparrini, D.; Gonzalez, Nuevo, J.; Leon-Tavares, J.; Lopez-Caniego, M.;
2012-01-01
We present simultaneous Planck, Swift, Fermi, and ground-based data for 105 blazars belonging to three samples with flux limits in the soft X-ray, hard X-ray, and gamma-ray bands, with additional 5 GHz flux-density limits to ensure a good probability of a Planck detection. We compare our results to those of a companion paper presenting simultaneous Planck and multi-frequency observations of 104 radio-loud northern active galactic nuclei selected at radio frequencies. While we confirm several previous results, our unique data set allows us to demonstrate that the selection method strongly influences the results, producing biases that cannot be ignored. Almost all the BL Lac objects have been detected by the Fermi Large Area Telescope (LAT), whereas 30% to 40% of the flat-spectrum radio quasars (FSRQs) in the radio, soft X-ray, and hard X-ray selected samples are still below the gamma-ray detection limit even after integrating 27 months of Fermi-LAT data. The radio to sub-millimetre spectral slope of blazars is quite flat, with (alpha) approx 0 up to about 70GHz, above which it steepens to (alpha) approx -0.65. The BL Lacs have significantly flatter spectra than FSRQs at higher frequencies. The distribution of the rest-frame synchrotron peak frequency (nu(sup s)(sub peak)) in the spectral energy distribution (SED) of FSRQs is the same in all the blazar samples with (nu(sup s)(sub peak)) = 10(exp 13.1 +/- 0.1) Hz, while the mean inverse Compton peak frequency, (nu(sup IC)(sub peak)), ranges from 10(exp 21) to 10(exp 22) Hz. The distributions of nu(sup s)(sub peak) and nu(sup IC)(sub peak) of BL Lacs are much broader and are shifted to higher energies than those of FSRQs; their shapes strongly depend on the selection method. The Compton dominance of blazars. defined as the ratio of the inverse Compton to synchrotron peak luminosities, ranges from less than 0.2 to nearly 100, with only FSRQs reaching values larger than about 3. Its distribution is broad and depends strongly on the selection method, with gamma-ray selected blazars peaking at approx 7 or more, and radio-selected blazars at values close to 1, thus implying that the common assumption that the blazar power budget is largely dominated by high-energy emission is a selection effect. A comparison of our multi-frequency data with theoretical predictions shows that simple homogeneous SSC models cannot explain the simultaneous SEDs of most of the gamma-ray detected blazars in all samples. The SED of the blazars that were not detected by FermiLAT may instead be consistent with SSC emission. Our data challenge the correlation between bolometric luminosity and nu(sup s)(sub peak) predicted by the blazar sequence.
Boyd, David A; Donald, Neil; Balshaw, Thomas G
2014-12-01
The purpose of this study was to compare acute countermovement jump (CMJ) responses after functional isometric (FI) and dynamic half (DH) squats. Ten strength-trained males (relative full back squat 1 repetition maximum [1RM]: 1.9 ± 0.2) participated in a randomized crossover design study. On 2 separate days, participants performed baseline CMJs followed by either FI or DH squats loaded with 150% of full back squat 1RM. Further CMJs were performed between 2 and 11 minutes after FI or DH squats. Kinematic and kinetic CMJ variables were measured. There were no differences observed between conditions when peak CMJ variables after FI or DH squats were compared with baseline values (p > 0.05). Countermovement jump time effects (p ≤ 0.05) were observed after squats. Increases in peak force (p ≤ 0.05; FI: 3.9%, range: -0.9 to 9.1%; DH: 4.2%, range: 0.0-11.5%) and decreases in peak power (p ≤ 0.05; FI: -0.4%, range: -5.1 to 4.0%; DH: -1.1%, range: -6.6 to 2.9%) occurred for combined condition data. Positive correlations between lower-body strength and the extent or timing of acute CMJ responses were not detected (p > 0.05). Because of the apparent lack of additive acute CMJ responses, the use of conventional DH squat protocols should be considered rather than FI squats in precompetition and training situations. Furthermore, the establishment of individual FI and DH squat protocols also seems to be necessary, rather than relying on relative lower-body strength to predict the nature of acute CMJ responses.
Response analysis of TLD-300 dosimeters in heavy-particle beams
NASA Astrophysics Data System (ADS)
Loncol, Th; Hamal, M.; Denis, J. M.; Vynckier, S.; Wambersie, A.; Scalliet, P.
1996-09-01
In vivo dosimetry is recommended as part of the quality control procedure for treatment verification in radiation therapy. Using thermoluminescence, such controls are planned in the p(65)+Be neutron and 85 MeV proton beams produced at the cyclotron at Louvain-La-Neuve and dedicated to therapy applications. A preliminary study of the peak 3 (
C) and peak 5 (
C) response of
:Tm (TLD-300) to neutron and proton beams aimed to analyse the effect of different radiation qualities on the dosimetric behaviour of the detector irradiated in phantom. To broaden the range of investigation, the study was extended to an experimental C-12 heavy ion beam (95 MeV/nucleon). The peak 3 and 5 sensitivities in the neutron beam, compared to Co-60, varied little with depth. A major change of peak 5 sensitivity was observed for samples positioned under five leaves of the multi-leaf collimator. While peak 3 sensitivity was constant with depth in the unmodulated proton beam, peak 5 sensitivity increased by 15%. Near the Bragg peak, peak 3 showed the highest decrease of sensitivity. In the modulated proton beam, the sensitivity values were not significantly smaller than those measured in the unmodulated beam far from the Bragg peak region. The ratio of the heights of peak 3 and peak 5 decreased by 70% from the Co-60 reference radiation to the C-12 heavy-ion beam. This parameter was strongly correlated with the change of radiation quality.
NASA Astrophysics Data System (ADS)
Kumar, Ajit; Verma, Sanjay K.; Alvi, P. A.; Jasrotia, Dinesh
2016-04-01
The nanospatial morphological features of [ZnCl]- [C5H4NCH3]+ hybrid derivative depicts 28 nm granular size and 3D spreader shape packing pattern as analyzed by FESEM and single crystal XRD structural studies. The organic moiety connect the inorganic components through N-H+…Cl- hydrogen bond to form a hybrid composite, the replacement of organic derivatives from 2-methylpyridine to 2-Amino-5-choloropyridine results the increase in granular size from 28nm to 60nm and unit cell packing pattern from 3D-2D lattice dimensionality along ac plane. The change in optical energy direct band gap value from 3.01eV for [ZnCl]- [C5H4NCH3]+ (HM1) to 3.42eV for [ZnCl]- [C5H5ClN2]+ (HM2) indicates the role of organic moiety in optical properties of hybrid materials. The photoluminescence emission spectra is observed in the wavelength range of 370 to 600 nm with maximum peak intensity of 9.66a.u. at 438 nm for (HM1) and 370 to 600 nm with max peak intensity of 9.91 a.u. at 442 nm for (HM2), indicating that the emission spectra lies in visible range. PL excitation spectra depicts the maximum excitation intensity [9.8] at 245.5 nm for (HM1) and its value of 9.9 a.u. at 294 nm, specify the excitation spectra lies in UV range. Photoluminescence excitation spectra is observed in the wavelength range of 280 to 350 nm with maximum peak intensity of 9.4 a.u. at 285.5 nm and 9.9 a.u. at 294 and 297 nm, indicating excitation in the UV spectrum. Single crystal growth process and detailed physiochemical characterization such as XRD, FESEM image analysis photoluminescence property reveals the structure stability with non-covalent interactions, lattice dimensionality (3D-2D) correlations interweaving into the design of inorganic-organic hybrid materials.
How to use your peak flow meter
Peak flow meter - how to use; Asthma - peak flow meter; Reactive airway disease - peak flow meter; Bronchial asthma - peak flow meter ... your airways are narrowed and blocked due to asthma, your peak flow values drop. You can check ...
Wu, Yanwei; Guo, Pan; Chen, Siying; Chen, He; Zhang, Yinchao
2017-04-01
Auto-adaptive background subtraction (AABS) is proposed as a denoising method for data processing of the coherent Doppler lidar (CDL). The method is proposed specifically for a low-signal-to-noise-ratio regime, in which the drifting power spectral density of CDL data occurs. Unlike the periodogram maximum (PM) and adaptive iteratively reweighted penalized least squares (airPLS), the proposed method presents reliable peaks and is thus advantageous in identifying peak locations. According to the analysis results of simulated and actually measured data, the proposed method outperforms the airPLS method and the PM algorithm in the furthest detectable range. The proposed method improves the detection range approximately up to 16.7% and 40% when compared to the airPLS method and the PM method, respectively. It also has smaller mean wind velocity and standard error values than the airPLS and PM methods. The AABS approach improves the quality of Doppler shift estimates and can be applied to obtain the whole wind profiling by the CDL.
Refraction index sensor based on phase resonances in a subwavelength structure with double period.
Skigin, Diana C; Lester, Marcelo
2016-10-01
In this paper, we numerically demonstrate a refraction index sensor based on phase resonance excitation in a subwavelength-slit structure with a double period. The sensor consists of a metal layer with subwavelength slots arranged in a bi-periodic form, separated from a high refraction index medium. Between the metallic structure and the incident medium, a dielectric waveguide is formed whose refraction index is going to be determined. Variations in the refraction index of the waveguide are detected as shifts in the peaks of transmitted intensity originated by resonant modes supported by the compound metallic structure. At normal incidence, the spectral position of these resonant peaks exhibits a linear or a quadratic dependence with the refraction index, which permits us to obtain the unknown refraction index value with a high precision for a wide range of wavelengths. Since the operating principle of the sensor is due to the morphological resonances of the slits' structure, this device can be scaled to operate in different wavelength ranges while keeping similar characteristics.
Chronic methylmercury exposure in the monkey (Macaca mulatta)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Luschei, E.; Mottet, N.K.; Shaw, C.M.
1977-01-01
Small daily doses of methylmercury hydroxide were administered to rhesus monkeys for periods of up to 17 months. Behavioral tests of peripheral vision and of the accuracy and rapidity of hand movements did not disclose any early subtle deficits preceding the onset of obvious signs of neurotoxicity. These signs appeared suddenly and involved reduced food intake (anorexia), clumsiness of jumping, loss of fine control of the digits, and uncoordinated mastication. With a constant daily dose of 0.1 mg/kg or less, blood concentration of mercury reached a peak after about 2 months, and then decreased to about half the peak value.more » Subsequently, increasing the daily dose level above 0.1 mg/kg (range of 0.12 to 0.21 mg/kg) produced an increase of blood concentration which tended to stabilize in the range of 2.0 to 2.5 ppM. After several months at these elevated concentrations all animals exhibited signs of neurotoxicity.« less
Imes, Jeffrey L.; Plummer, Niel; Kleeschulte, Michael J.; Schumacher, John G.
2007-01-01
Exploration for lead deposits has occurred in a mature karst area of southeast Missouri that is highly valued for its scenic beauty and recreational opportunities. The area contains the two largest springs in Missouri (Big Spring and Greer Spring), both of which flow into federally designated scenic rivers. Concerns about potential mining effects on the area ground water and aquatic biota prompted an investigation of Big Spring. Water-level measurements made during 2000 helped define the recharge area of Big Spring, Greer Spring, Mammoth Spring, and Boze Mill Spring. The data infer two distinct potentiometric surfaces. The shallow potentiometric surface, where the depth-to-water is less than about 250 feet, tends to mimic topographic features and is strongly controlled by streams. The deep potentiometric surface, where the depth-to-water is greater than about 250 feet represents ground-water hydraulic heads within the more mature karst areas. A highly permeable zone extends about 20 mile west of Big Spring toward the upper Hurricane Creek Basin. Deeper flowing water in the Big Spring recharge area is directed toward this permeable zone. The estimated sizes of the spring recharge areas are 426 square miles for Big Spring, 352 square miles for Greer Spring, 290 square miles for Mammoth Spring, and 54 square miles for Boze Mill Spring. A discharge accumulation curve using Big Spring daily mean discharge data shows no substantial change in the discharge pattern of Big Spring during the period of record (water years 1922 through 2004). The extended periods when the spring flow deviated from the trend line can be attributed to prolonged departures from normal precipitation. The maximum possible instantaneous flow from Big Spring has not been adequately defined because of backwater effects from the Current River during high-flow conditions. Physical constraints within the spring conduit system may restrict its maximum flow. The largest discharge measured at Big Spring during the period of record (water years 1922 through 2004) was 1,170 cubic feet per second on December 7, 1982. The daily mean water temperature of Big Spring was monitored during water years 2001 through 2004 and showed little variability, ranging from 13 to 15? C (degree Celsius). Water temperatures generally vary less than 1? C throughout the year. The warmest temperatures occur during October and November and decrease until April, indicating Big Spring water temperature does show a slight seasonal variation. The use of the traditional hydrograph separation program HYSEP to determine the base flow and quick flow or runoff components at Big Spring failed to yield base-flow and quick-flow discharge curves that matched observations of spring characteristics. Big Spring discharge data were used in combination with specific conductance data to develop an improved hydrograph separation method for the spring. The estimated annual mean quick flow ranged from 15 to 48 cubic feet per second for the HYSEP analysis and ranged from 26 to 154 cubic feet per second for the discharge and specific conductance method for water years 2001 to 2004. Using the discharge and specific conductance method, the estimated base-flow component rises abruptly as the spring hydrograph rises, attains a peak value on the same day as the discharge peak, and then declines abruptly from its peak value. Several days later, base flow begins to increase again at an approximately linear trend, coinciding with the time at which the percentage of quick flow has reached a maximum after each recharge-induced discharge peak. The interval between the discharge peak and the peak in percentage quick flow ranges from 8 to 11 days for seven hydrograph peaks, consistent with quick-flow traveltime estimates by dye-trace tests from the mature karst Hurricane Creek Basin in the central part of the recharge area. Concentrations of environmental tracers chlorofluorocarbons (CFCs: CFC-11, CFC-12, CFC-113)
Yu, Kate; Little, David; Plumb, Rob; Smith, Brian
2006-01-01
A quantitative Ultra Performance liquid chromatography/tandem mass spectrometry (UPL/MS/MS) protocol was developed for a five-compound mixture in rat plasma. A similar high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) quantification protocol was developed for comparison purposes. Among the five test compounds, three preferred positive electrospray ionization (ESI) and two preferred negative ESI. As a result, both UPLC/MS/MS and HPLC/MS/MS analyses were performed by having the mass spectrometer collecting ESI multiple reaction monitoring (MRM) data in both positive and negative ion modes during a single injection. Peak widths for most standards were 4.8 s for the HPLC analysis and 2.4 s for the UPLC analysis. There were 17 to 20 data points obtained for each of the LC peaks. Compared with the HPLC/MS/MS method, the UPLC/MS/MS method offered 3-fold decrease in retention time, up to 10-fold increase in detected peak height, with 2-fold decrease in peak width. Limits of quantification (LOQs) for both HPLC and UPLC methods were evaluated. For UPLC/MS/MS analysis, a linear range up to four orders of magnitude was obtained with r2 values ranging from 0.991 to 0.998. The LOQs for the five analytes ranged from 0.08 to 9.85 ng/mL. Three levels of quality control (QC) samples were analyzed. For the UPLC/MS/MS protocol, the percent relative standard deviation (RSD%) for low QC (2 ng/mL) ranged from 3.42 to 8.67% (N = 18). The carryover of the UPLC/MS/MS protocol was negligible and the robustness of the UPLC/MS/MS system was evaluated with up to 963 QC injections. Copyright 2006 John Wiley & Sons, Ltd.
The impact law of confining pressure and plastic parameter on Dilatancy of rock
NASA Astrophysics Data System (ADS)
Wang, Bin; Zhang, Zhenjie; Zhu, Jiebing
2017-08-01
Based on cyclic loading-unloading triaxle test of marble, the double parameter dilation angle model is established considering confining pressure effect and plastic parameter. Research shows that not only the strength but also the militancy behavior is highly depended on its confining pressure and plastic parameter during process of failure. Dilation angle evolution law shows obvious nonlinear characteristic almost with a rapid increase to the peak and then decrease gradually with plastic increasing, and the peak dilation angle value is inversely proportional with confining pressure. The proposed double parameter nonlinear dilation angle model can be used to well describe the Dilatancy of rock, which helps to understand the failure mechanism of surrounding rock mass and predict the range of plastic zone.
An empirical formula to calculate the full energy peak efficiency of scintillation detectors.
Badawi, Mohamed S; Abd-Elzaher, Mohamed; Thabet, Abouzeid A; El-khatib, Ahmed M
2013-04-01
This work provides an empirical formula to calculate the FEPE for different detectors using the effective solid angle ratio derived from experimental measurements. The full energy peak efficiency (FEPE) curves of the (2″(*)2″) NaI(Tl) detector at different seven axial distances from the detector were depicted in a wide energy range from 59.53 to 1408keV using standard point sources. The distinction was based on the effects of the source energy and the source-to-detector distance. A good agreement was noticed between the measured and calculated efficiency values for the source-to-detector distances at 20, 25, 30, 35, 40, 45 and 50cm. Copyright © 2012 Elsevier Ltd. All rights reserved.
Bertelloni, Silvano; Baroncelli, Giampiero I; Dati, Eleonora; Ghione, Silvia; Baldinotti, Fulvia; Toschi, Benedetta; Simi, Paolo
2013-01-01
Short stature represents one of the main features of children with Noonan syndrome. The reason for impaired growth remains largely unknown. To assess GH and IGF1 secretion in children with Noonan syndrome. 12 prepubertal children with Noonan syndrome due to mutations in the PTPN11 gene [7 males, 6 females; median age, years: 8.6 (range 5.1-13.4)] were studied; 12 prepubertal children with short stature (SS) [7 males, 5 females; median age, years: 8.1 (range 4.8-13.1)] served as the control group. GH secretion after arginine stimulation test; IGF1 generation test by measurement of IGF1 levels before and after recombinant GH (rGH) administration (0.05 mg/kg/day for 4 days). Baseline and stimulated peak values of GH were not significantly different between the two groups. At +120 minutes, GH levels remained significantly higher (p = 0.0121) in comparison with baseline values in children with Noonan syndrome. Baseline IGFI levels in patients and in SS controls were not significantly different, in contrast to values after the rGH generation test [205 ng/mL (interquartiles 138.2-252.5 ng/mL) and 284.5 ng/mL (interquartiles 172-476 ng/mL), respectively; p = 0.0248]. IGF1 values were significantly related to height (baseline: r = 773, p = 0.0320; peak: r = 0.591, p = 0.0428) in children with Noonan syndrome. Blunted increase of IGF1 after the rGH generation test was present in children with Noonan syndrome due to mutations in the PTPN11 gene in comparison with SS children. This finding may be due to partial GH resistance in the former likely related to altered Ras-MAPK signaling pathway.
1990-05-03
winter and a minimum in summer ; in contrast, at sunspot maximum the seasonal peaks tend to occur around the equinoxes and the minima in summer . ’riis is...more clearly seen in Figures 4(b) ahnd 4(c). Note that around sunspot maximum the summer noon value may be less than the summer midnight value. (3) The...seasonal variation of the midnight values show summer peaks and winter minima with high values near the peaks of the sunspot cycles and low values
DOE Office of Scientific and Technical Information (OSTI.GOV)
Srinivasan, M.G.; Kot, C.A.; Mojtahed, M.
The paper describes the analytical modeling, calculations, and results of the posttest nonlinear simulation of high-level seismic testing of the VKL piping system at the HDR Test Facility in Germany. One of the objectives of the tests was to evaluate analytical methods for calculating the nonlinear response of realistic piping systems subjected to high-level seismic excitation that would induce significant plastic deformation. Two out of the six different pipe-support configurations, (ranging from a stiff system with struts and snubbers to a very flexible system with practically no seismic supports), subjected to simulated earthquakes, were tested at very high levels. Themore » posttest nonlinear calculations cover the KWU configuration, a reasonably compliant system with only rigid struts. Responses for 800% safe-shutdown-earthquake loading were calculated using the NONPIPE code. The responses calculated with NONPIPE were found generally to have the same time trends as the measurements but contained under-, over-, and correct estimates of peak values, almost in equal proportions. The only exceptions were the peak strut forces, which were underestimated as a group. The scatter in the peak value estimate of displacements and strut forces was smaller than that for the strains. The possible reasons for the differences and the effort on further analysis are discussed.« less
F2 layer characteristics and electrojet strength over an equatorial station
NASA Astrophysics Data System (ADS)
Adebesin, B. O.; Adeniyi, J. O.; Adimula, I. A.; Reinisch, B. W.; Yumoto, K.
2013-09-01
The data presented in this work describes the diurnal and seasonal variation in hmF2, NmF2, and the electrojet current strength over an African equatorial station during a period of low solar activity. The F2 region horizontal magnetic element H revealed that the Solar quiet Sq(H) daily variation rises from early morning period to maximum around local noon and falls to lower values towards evening. The F2 ionospheric current responsible for the magnetic field variations is inferred to build up at the early morning hours, attaining maximum strength around 1200 LT. The Sq variation across the entire months was higher during the daytime than nighttime. This is ascribed to the variability of the ionospheric parameters like conductivity and winds structure in this region. Seasonal daytime electrojet (EEJ) current strength for June solstice, March and September equinoxes, respectively had peak values ranging within 27-35 nT (at 1400 LT) , 30-40 nT (at 1200 LT) and 35-45 nT (at 1500 LT). The different peak periods of the EEJ strength were attributed to the combined effects of the peak electron density and electric field. Lastly, the EEJ strength was observed to be higher during the equinoxes than the solstice period.
NASA Astrophysics Data System (ADS)
Zhou, Anran; Xie, Weixin; Pei, Jihong
2018-06-01
Accurate detection of maritime targets in infrared imagery under various sea clutter conditions is always a challenging task. The fractional Fourier transform (FRFT) is the extension of the Fourier transform in the fractional order, and has richer spatial-frequency information. By combining it with the high order statistic filtering, a new ship detection method is proposed. First, the proper range of angle parameter is determined to make it easier for the ship components and background to be separated. Second, a new high order statistic curve (HOSC) at each fractional frequency point is designed. It is proved that maximal peak interval in HOSC reflects the target information, while the points outside the interval reflect the background. And the value of HOSC relative to the ship is much bigger than that to the sea clutter. Then, search the curve's maximal target peak interval and extract the interval by bandpass filtering in fractional Fourier domain. The value outside the peak interval of HOSC decreases rapidly to 0, so the background is effectively suppressed. Finally, the detection result is obtained by the double threshold segmenting and the target region selection method. The results show the proposed method is excellent for maritime targets detection with high clutters.
Eckner, James T; Rettmann, Ashley; Narisetty, Naveen; Greer, Jacob; Moore, Brandon; Brimacombe, Susan; He, Xuming; Broglio, Steven P
2016-01-01
To determine test-re-test reliabilities of novel Evoked Response Potential (ERP)-based Brain Network Activation (BNA) scores in healthy athletes. Observational, repeated-measures study. Forty-two healthy male and female high school and collegiate athletes completed auditory oddball and go/no-go ERP assessments at baseline, 1 week, 6 weeks and 1 year. The BNA algorithm was applied to the ERP data, considering electrode location, frequency band, peak latency and normalized amplitude to generate seven unique BNA scores for each testing session. Mean BNA scores, intra-class correlation coefficient (ICC) values and reliable change (RC) values were calculated for each of the seven BNA networks. BNA scores ranged from 46.3 ± 34.9 to 69.9 ± 22.8, ICC values ranged from 0.46-0.65 and 95% RC values ranged from 38.3-68.1 across the seven networks. The wide range of BNA scores observed in this population of healthy athletes suggests that a single BNA score or set of BNA scores from a single after-injury test session may be difficult to interpret in isolation without knowledge of the athlete's own baseline BNA score(s) and/or the results of serial tests performed at additional time points. The stability of each BNA network should be considered when interpreting test-re-test BNA score changes.
Chatterjee, Niladri Sekhar; Kumar, K Ashok; Ajeeshkumar, K K; Kumari, K R Remya; Vishnu, K V; Anandan, Rangasamy; Mathew, Suseela; Ravishankar, C N
2017-05-01
Despite the potential of LC with tandem MS (MS/MS) in improving sensitivity and selectivity, analytical methods are scarce for the determination of protein-bound and phosphorylated forms of B vitamins in food. This prompted us to develop a method for LC-MS/MS determination of naturally occurring nicotinamide, nicotinic acid, thiamine, pyridoxine, riboflavin, pantothenic acid, biotin, folic acid, and cyanocobalamin in fish. Baseline separation of the vitamins was achieved in a hydrophilic interaction LC condition. An ultrasonication-assisted enzymatic extraction protocol for sample preparation was optimized and validated. The time required for extraction was significantly reduced (to 4 h), while maintaining good extraction efficiency. Acetonitrile content (80%, v/v) in the prepared sample was found to be optimum for excellent peak shape and sensitivity. The dynamic linear range of the vitamins ranged from 2.5 to 500 ng/g, and the regression coefficient values were greater than 0.99. LOQ values ranged from 0.4 to 50 ng/g for the different vitamins. The spike recovery values at 50 and 100 ng/g ranged from 87.5 to 97.5%. The intra- and interday precision values were satisfactory. Accuracy of the developed method was determined by analysis of a Certified Reference Material. The method could also be used for unambiguous determination of the natural content of the target vitamins in fish.
Generation of synthetic flood hydrographs by hydrological donors (SHYDONHY method)
NASA Astrophysics Data System (ADS)
Paquet, Emmanuel
2017-04-01
For the design of hydraulic infrastructures like dams, a design hydrograph is required in most of the cases. Some of its features (e.g. peak value, duration, volume) corresponding to a given return period are computed thanks to a wide range of methods: historical records, mono or multivariate statistical analysis, stochastic simulation, etc. Then various methods have been proposed to construct design hydrographs having such characteristics, ranging from traditional unit-hydrograph to statistical methods (Yue et al., 2002). A new method to build design hydrographs (or more generally synthetic hydrographs) is introduced here, named SHYDONHY, French acronym for "Synthèse d'HYdrogrammes par DONneurs HYdrologiques". It is based on an extensive database of 100 000 flood hydrographs recorded at hourly time-step on 1300 gauging stations in France and Switzerland, covering a wide range of catchment size and climatology. For each station, an average of two hydrographs per year of record has been selected by a peak-over-threshold (POT) method with independence criteria (Lang et al., 1999). This sampling ensures that only hydrographs of intense floods are gathered in the dataset. For a given catchment, where few or no hydrograph is available at the outlet, a sub-set of 10 "donor stations" is selected within the complete dataset, considering several criteria: proximity, size, mean annual values and regimes for both total runoff and POT-selected floods. This sub-set of stations (and their corresponding flood hydrographs) will allow to: • Estimate a characteristic duration of flood hydrographs (e.g. duration for which the discharge is above 50% of the peak value). • For a given duration (e.g. one day), estimate the average peak-to- volume ratio of floods. • For a given duration and peak-to-volume ratio, generation of a synthetic reference hydrograph by combining appropriate hydrographs of the sub-set. • For a given daily discharge sequence, being observed or generated for extreme flood estimation, generate a suitable synthetic hydrograph, also by combining selected hydrographs of the sub-set. The reliability of the method is assessed by performing a jackknife validation on the whole dataset of stations, in particular by reconstructing the hydrograph of the biggest flood of each station and comparing it to the actual one. Some applications are presented, e.g. the coupling of SHYDONHY with the SCHADEX method (Paquet et al., 2003) for the stochastic simulation of extreme reservoir level in dams. References: Lang, M., Ouarda, T. B. M. J., & Bobée, B. (1999). Towards operational guidelines for over-threshold modeling. Journal of hydrology, 225(3), 103-117. Paquet, E., Garavaglia, F., Garçon, R., & Gailhard, J. (2013). The SCHADEX method: A semi-continuous rainfall-runoff simulation for extreme flood estimation. Journal of Hydrology, 495, 23-37. Yue, S., Ouarda, T. B., Bobée, B., Legendre, P., & Bruneau, P. (2002). Approach for describing statistical properties of flood hydrograph. Journal of hydrologic engineering, 7(2), 147-153.
Kousi, Evanthia; Smith, Joely; Ledger, Araminta E; Scurr, Erica; Allen, Steven; Wilson, Robin M; O'Flynn, Elizabeth; Pope, Romney J E; Leach, Martin O; Schmidt, Maria A
2018-01-01
To propose a method to quantify T 1 and contrast agent uptake in breast dynamic contrast-enhanced (DCE) examinations undertaken with standard clinical fat-suppressed MRI sequences and to demonstrate the proposed approach by comparing the enhancement characteristics of lobular and ductal carcinomas. A standard fat-suppressed DCE of the breast was performed at 1.5 T (Siemens Aera), followed by the acquisition of a proton density (PD)-weighted sequence, also fat suppressed. Both sequences were characterized with test objects (T 1 ranging from 30 ms to 2,400 ms) and calibration curves were obtained to enable T 1 calculation. The reproducibility and accuracy of the calibration curves were also investigated. Healthy volunteers and patients were scanned with Ethics Committee approval. The effect of B 0 field inhomogeneity was assessed in test objects and healthy volunteers. The T 1 of breast tumors was calculated at different time points (pre-, peak-, and post-contrast agent administration) for 20 patients, pre-treatment (10 lobular and 10 ductal carcinomas) and the two cancer types were compared (Wilcoxon rank-sum test). The calibration curves proved to be highly reproducible (coefficient of variation under 10%). T 1 measurements were affected by B 0 field inhomogeneity, but frequency shifts below 50 Hz introduced only 3% change to fat-suppressed T 1 measurements of breast parenchyma in volunteers. The values of T 1 measured pre-, peak-, and post-contrast agent administration demonstrated that the dynamic range of the DCE sequence was correct, that is, image intensity is approximately directly proportional to 1/T 1 for that range. Significant differences were identified in the width of the distributions of the post-contrast T 1 values between lobular and ductal carcinomas (P < 0.05); lobular carcinomas demonstrated a wider range of post-contrast T 1 values, potentially related to their infiltrative growth pattern. This work has demonstrated the feasibility of fat-suppressed T 1 measurements as a tool for clinical studies. The proposed quantitative approach is practical, enabled the detection of differences between lobular and invasive ductal carcinomas, and further enables the optimization of DCE protocols by tailoring the dynamic range of the sequence to the values of T 1 measured. © 2017 The Authors. Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
Quality assurance of proton beams using a multilayer ionization chamber system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dhanesar, Sandeep; Sahoo, Narayan; Kerr, Matthew
2013-09-15
Purpose: The measurement of percentage depth-dose (PDD) distributions for the quality assurance of clinical proton beams is most commonly performed with a computerized water tank dosimetry system with ionization chamber, commonly referred to as water tank. Although the accuracy and reproducibility of this method is well established, it can be time-consuming if a large number of measurements are required. In this work the authors evaluate the linearity, reproducibility, sensitivity to field size, accuracy, and time-savings of another system: the Zebra, a multilayer ionization chamber system.Methods: The Zebra, consisting of 180 parallel-plate ionization chambers with 2 mm resolution, was used tomore » measure depth-dose distributions. The measurements were performed for scattered and scanned proton pencil beams of multiple energies delivered by the Hitachi PROBEAT synchrotron-based delivery system. For scattered beams, the Zebra-measured depth-dose distributions were compared with those measured with the water tank. The principal descriptors extracted for comparisons were: range, the depth of the distal 90% dose; spread-out Bragg peak (SOBP) length, the region between the proximal 95% and distal 90% dose; and distal-dose fall off (DDF), the region between the distal 80% and 20% dose. For scanned beams, the Zebra-measured ranges were compared with those acquired using a Bragg peak chamber during commissioning.Results: The Zebra demonstrated better than 1% reproducibility and monitor unit linearity. The response of the Zebra was found to be sensitive to radiation field sizes greater than 12.5 × 12.5 cm; hence, the measurements used to determine accuracy were performed using a field size of 10 × 10 cm. For the scattered proton beams, PDD distributions showed 1.5% agreement within the SOBP, and 3.8% outside. Range values agreed within −0.1 ± 0.4 mm, with a maximum deviation of 1.2 mm. SOBP length values agreed within 0 ± 2 mm, with a maximum deviation of 6 mm. DDF values agreed within 0.3 ± 0.1 mm, with a maximum deviation of 0.6 mm. For the scanned proton pencil beams, Zebra and Bragg peak chamber range values demonstrated agreement of 0.0 ± 0.3 mm with a maximum deviation of 1.3 mm. The setup and measurement time for all Zebra measurements was 3 and 20 times less, respectively, compared to the water tank measurements.Conclusions: Our investigation shows that the Zebra can be useful not only for fast but also for accurate measurements of the depth-dose distributions of both scattered and scanned proton beams. The analysis of a large set of measurements shows that the commonly assessed beam quality parameters obtained with the Zebra are within the acceptable variations specified by the manufacturer for our delivery system.« less
NASA Astrophysics Data System (ADS)
He, H.-Q.; Zhou, G.; Wan, W.
2017-06-01
A functional form {I}\\max (R)={{kR}}-α , where R is the radial distance of a spacecraft, was usually used to model the radial dependence of peak intensities {I}\\max (R) of solar energetic particles (SEPs). In this work, the five-dimensional Fokker-Planck transport equation incorporating perpendicular diffusion is numerically solved to investigate the radial dependence of SEP peak intensities. We consider two different scenarios for the distribution of a spacecraft fleet: (1) along the radial direction line and (2) along the Parker magnetic field line. We find that the index α in the above expression varies in a wide range, primarily depending on the properties (e.g., location and coverage) of SEP sources and on the longitudinal and latitudinal separations between the sources and the magnetic foot points of the observers. Particularly, whether the magnetic foot point of the observer is located inside or outside the SEP source is a crucial factor determining the values of index α. A two-phase phenomenon is found in the radial dependence of peak intensities. The “position” of the break point (transition point/critical point) is determined by the magnetic connection status of the observers. This finding suggests that a very careful examination of the magnetic connection between the SEP source and each spacecraft should be taken in the observational studies. We obtain a lower limit of {R}-1.7+/- 0.1 for empirically modeling the radial dependence of SEP peak intensities. Our findings in this work can be used to explain the majority of the previous multispacecraft survey results, and especially to reconcile the different or conflicting empirical values of the index α in the literature.
Segal, Scott; Fox, John A.; Eltzschig, Holger K.; Shernan, Stanton K.
2011-01-01
Objective Acute mitral stenosis (MS) following mitral valve (MV) repair is a rare but severe complication. We hypothesize that intraoperative echocardiography can be utilized to diagnose iatrogenic MS immediately after MV repair. Methods The medical records of 552 consecutive patients undergoing MV repair at a single institution were reviewed. Post-cardiopulmonary bypass peak and mean transmitral pressure gradients (TMPG), and pressure half time (PHT) were obtained from intraoperative transesophageal echocardiographic (TEE) examinations in each patient. Results Nine patients (9/552 = 1.6%) received a reoperation for primary MS, prior to hospital discharge. Interestingly, all of these patients already showed intraoperative post-CPB mean and peak TMPGs that were significantly higher compared to values for those who did not: 10.7±4.8 mmHg vs 2.9±1.6 mmHg; p<0.0001 and 22.9±7.9 mmHg vs 7.6±3.7 mmHg; p<0.0001, respectively. However, PHT varied considerably (87±37 ms; range: 20–439 ms) within the entire population, and only weakly predicted the requirement for reoperation (113±56 vs. 87±37 ms, p = 0.034). Receiver operating characteristic curves showed strong discriminating ability for mean gradients (AUC = 0.993) and peak gradients (area under the curve, AUC = 0.996), but poor performance for PHT (AUC = 0.640). A value of ≥7 mmHg for mean, and ≥17 mmHg for peak TMPG, best separated patients who required reoperation for MS from those who did not. Conclusions Intraoperative TEE diagnosis of a peak TMPG ≥17 mmHg or mean TMPG ≥7 mmHg immediately following CPB are suggestive of clinically relevant MS after MV repair. PMID:22087230
Neupane, Umesh; Rai, R N
2017-11-01
The phase diagram representing solid-liquid equilibrium of entire range of composition and thermodynamic studies of two binary organic systems of 4-dimethylaminobenzaldehyde (DMAB) with two NLO active compounds, p-aminoacetanilide (PAA) and p-nitroaniline (PNA), have been studied by solid state synthetic route. Both systems are independently forming a new entity called intermolecular complex (IMC) and two eutectics on either side of intermolecular complexes. The various thermodynamic parameters such as heat of mixing, entropy of fusion, roughness parameter, interfacial energy and excess thermodynamic functions of IMCs and eutectics were calculated using the heat of fusion values. The TGA and DTA studies were performed to understand the physico-chemical, thermal behavior and unique identity of newly synthesized organic complexes, 4-(dimethylamino)benzylidene-4-acetamideaniline (DMABPAA) and 4-(dimethylamino)benzylidene-4-nitroaniline (DMABPNA), and their respective enthalpy of fusion values were found to be 30.01 and 37.26 kJ mol - 1 . The higher melting point of both the novel complexes than their parent's compounds reveal the strong molecular interaction between parent components to yield the complex. The FTIR spectral analysis predicts the disappearance of aldehyde peaks of DMAB and NH 2 peaks of PAA and PNA while the appearance of entirely new peaks than that of parent's compounds are the supportive for the formation of new molecular entities. These findings are further supported by FTNMR spectrum studies by observation of disappearance of proton peak of aldehyde of DMAB and amine peaks of PAA and PNA rather formation of new imine proton peak or peaks were observed. The appearance of new peaks in Powder XRD of complexes than those of parent components is further indicative for the formation of complexes. The absorption spectrum of DMABPAA and DMABPNA showed intra-molecular charge-transfer (ICT) excited state absorption at 258 and 241 nm, respectively. Both the IMCs, DMABPAA and DMABPNA, show strong fluorescence with quantum yield 0.66 and 0.93, respectively, in methanol solution.
Spectral investigation of somatotropin for different pH values
NASA Astrophysics Data System (ADS)
Otero de Joshi, Virginia; Gil, Herminia; Contreras, Silvia; Joshi, Narahari V.; Hernandez, Luis
1996-04-01
Spectral investigations of absorbance in deep ultra-violet region (from 200 nm to 350 nm) of (STM) was carried out for different pH values. On the high energy side the peak is located at 195 nm which is generally attributed to peptide bonds. This peak, as expected, does not show any shift with pH value (4.3 to 10.8). A rather broad peak is spread in the region from 200 nm to 240 nm which could be the superposition of the peaks corresponding to the absorption due to (alpha) helix and (beta) structure. This peak shows a red shift as pH value increases. The same hormone was glycated by a conventional method and the process was estimated with the absorption spectra. The results are discussed in the light of nonenzymatic glycation. It was found that glycation mucus somatotropin resistant towards the denaturation process.
Raman bandshape analysis of the symmetric bending vibration in liquid chloroform
NASA Astrophysics Data System (ADS)
Yuan, P.; Schwartz, M.
In order to determine whether accurate rotational diffusion coefficients in liquids may be determined from the bandshapes of isotopically broadened vibrational peaks, we have investigated the isotropic and anisotropic Raman spectra of the ν 3( A1), CCl 3 symmetric bending, vibration in CHCl 3 as a function of temperature in the liquid phase. The spectral lineshapes were fitted by a model containing four Lorentzian/Gaussian summation bands with relative peak intensities equal to the relative abundances of the four isotopic combinations and frequency displacements constrained to values measured in the matrix infrared spectrum. The calculated room temperature perpendicular diffusion coefficient, D⊥ (25°C) = 8.310 10 s -1, was within the range of values reported from Raman measurements on the ν 1, symmetric carbon-hydrogen stretching, vibration, but was somewhat lower than published results from NMR relaxation time measurements, T1( 2D), on CDCl 3, and from dielectric relaxation. The activation energy, Ea( D⊥), determined from the ν 3 bandshape measurements was 30% higher than the average value from the NMR and dielectric studies. The deviation is believed to result from the sensitivity of this quantity to the fractional Lorentzian character of the fitting functions.
NASA Astrophysics Data System (ADS)
Rojali, Salman, Afan Galih; George
2017-08-01
Along with the development of information technology in meeting the needs, various adverse actions and difficult to avoid are emerging. One of such action is data theft. Therefore, this study will discuss about cryptography and steganography that aims to overcome these problems. This study will use the Modification Vigenere Cipher, Least Significant Bit and Dictionary Based Compression methods. To determine the performance of study, Peak Signal to Noise Ratio (PSNR) method is used to measure objectively and Mean Opinion Score (MOS) method is used to measure subjectively, also, the performance of this study will be compared to other method such as Spread Spectrum and Pixel Value differencing. After comparing, it can be concluded that this study can provide better performance when compared to other methods (Spread Spectrum and Pixel Value Differencing) and has a range of MSE values (0.0191622-0.05275) and PSNR (60.909 to 65.306) with a hidden file size of 18 kb and has a MOS value range (4.214 to 4.722) or image quality that is approaching very good.
Optically Tuned MM-Wave IMPATT Source.
1987-07-01
phase of the work has been extended and generalised. Accuracy of the theory in predicting tuning at the higher oscillator voltage swings has been greatly...Accuracy of the theory in predicting tuning at the higher oscillator voltage swings has been greatly improved by reformulating the Bessel function...voltage modulation and a peak optically injected locking current of 100 pA the predicted ftl locking range would be 540MHz, a practicaUy useful value. 4
DEVELOPMENT OF AN ARMY STATIONARY AXLE TEST STAND FOR LUBRICANT EFFICIENCY EVALUATION-PART II
2017-01-13
value was estimated based on the engines maximum peak torque output, multiplied by the transmissions 1st gear ratio, high range transfer case ratio...efficiency test stand to allow for laboratory based investigation of Fuel Efficient Gear Oils (FEGO) and their impact on vehicle efficiency. Development...their impact on vehicle efficiency. The test stand was designed and developed with the following goals: • Provide a lower cost alternative for
Ground-water levels, flow, and quality in northwestern Elkhart County, Indiana, 1980-89
Duwelius, R.F.; Silcox, C.A.
1991-01-01
The time of peak dissolved-bromide concentrations in water from shallow wells downgradient from the landfill was used to estimate a rate of horizontal flow of water in the unconfined aquifer. The average rate of flow between shallow wells downgradient from the landfill was estimated to be 1.2 feet per day. This rate is within the range of values for ground-water flow calculated according to Darcy's law.
Transport Properties of the Nuclear Pasta Phase with Quantum Molecular Dynamics
NASA Astrophysics Data System (ADS)
Nandi, Rana; Schramm, Stefan
2018-01-01
We study the transport properties of nuclear pasta for a wide range of density, temperature, and proton fractions, relevant for different astrophysical scenarios adopting a quantum molecular dynamics model. In particular, we estimate the values of shear viscosity as well as electrical and thermal conductivities by calculating the static structure factor S(q) using simulation data. In the density and temperature range where the pasta phase appears, the static structure factor shows irregular behavior. The presence of a slab phase greatly enhances the peak in S(q). However, the effect of irregularities in S(q) on the transport coefficients is not very dramatic. The values of all three transport coefficients are found to have the same orders of magnitude as found in theoretical calculations for the inner crust matter of neutron stars without the pasta phase; therefore, the values are in contrast to earlier speculations that a pasta layer might be highly resistive, both thermally and electrically.
Chen, Liangyou; Reisner, Andrew T; Gribok, Andrei; Reifman, Jaques
2010-11-01
It has been widely accepted that metrics related to respiration-induced waveform variation (RIWV) of the photoplethysmogram (PPG) have been associated with hypovolemia in mechanically ventilated patients and in controlled laboratory environments. In this retrospective study, we investigated if PPG RIWV metrics have diagnostic value for patients with acute hemorrhagic hypovolemia in the prehospital environment. Photoplethysmogram waveforms and basic vital signs were recorded in trauma patients during prehospital transport. Retrospectively, we used automated algorithms to select patient records with all five basic vital signs and 45 s or longer continuous, clean PPG segments. From these segments, we identified the onset and peak of individual heartbeats and computed waveform variations in the beats' peaks and amplitudes: (1) as the range between the maximum and the minimum (max-min) values and (2) as their interquartile range (IQR). We evaluated their receiver operating characteristic (ROC) curves for major hemorrhage. Separately, we tested whether RIWV metrics have potential independent information beyond basic vital signs by applying multivariate regression. In 344 patients, RIWV max-min yielded areas under the ROC curves (AUCs) not significantly better than a random AUC of 0.50. Respiration-induced waveform variation computed as IQR yielded ROC AUCs of 0.65 (95% confidence interval, 0.54-0.76) and of 0.64 (0.51-0.75), for peak and amplitude measures, respectively. The IQR metrics added independent information to basic vital signs (P < 0.05), but only moderately improved the overall AUC. Photoplethysmogram RIWV measured as IQR is preferable over max-min, and using PPG RIWV may enhance physiologic monitoring of spontaneously breathing patients outside strictly controlled laboratory environments.
Bilbao, Aivett; Gibbons, Bryson C.; Slysz, Gordon W.; ...
2017-11-06
We present that the mass accuracy and peak intensity of ions detected by mass spectrometry (MS) measurements are essential to facilitate compound identification and quantitation. However, high concentration species can yield erroneous results if their ion intensities reach beyond the limits of the detection system, leading to distorted and non-ideal detector response (e.g. saturation), and largely precluding the calculation of accurate m/z and intensity values. Here we present an open source computational method to correct peaks above a defined intensity (saturated) threshold determined by the MS instrumentation such as the analog-to-digital converters or time-to-digital converters used in conjunction with time-of-flightmore » MS. Here, in this method, the isotopic envelope for each observed ion above the saturation threshold is compared to its expected theoretical isotopic distribution. The most intense isotopic peak for which saturation does not occur is then utilized to re-calculate the precursor m/z and correct the intensity, resulting in both higher mass accuracy and greater dynamic range. The benefits of this approach were evaluated with proteomic and lipidomic datasets of varying complexities. After correcting the high concentration species, reduced mass errors and enhanced dynamic range were observed for both simple and complex omic samples. Specifically, the mass error dropped by more than 50% in most cases for highly saturated species and dynamic range increased by 1–2 orders of magnitude for peptides in a blood serum sample.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bilbao, Aivett; Gibbons, Bryson C.; Slysz, Gordon W.
The mass accuracy and peak intensity of ions detected by mass spectrometry (MS) measurements are essential to facilitate compound identification and quantitation. However, high concentration species can easily cause problems if their ion intensities reach beyond the limits of the detection system, leading to distorted and non-ideal detector response (e.g. saturation), and largely precluding the calculation of accurate m/z and intensity values. Here we present an open source computational method to correct peaks above a defined intensity (saturated) threshold determined by the MS instrumentation such as the analog-to-digital converters or time-to-digital converters used in conjunction with time-of-flight MS. In thismore » method, the isotopic envelope for each observed ion above the saturation threshold is compared to its expected theoretical isotopic distribution. The most intense isotopic peak for which saturation does not occur is then utilized to re-calculate the precursor m/z and correct the intensity, resulting in both higher mass accuracy and greater dynamic range. The benefits of this approach were evaluated with proteomic and lipidomic datasets of varying complexities. After correcting the high concentration species, reduced mass errors and enhanced dynamic range were observed for both simple and complex omic samples. Specifically, the mass error dropped by more than 50% in most cases with highly saturated species and dynamic range increased by 1-2 orders of magnitude for peptides in a blood serum sample.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bilbao, Aivett; Gibbons, Bryson C.; Slysz, Gordon W.
We present that the mass accuracy and peak intensity of ions detected by mass spectrometry (MS) measurements are essential to facilitate compound identification and quantitation. However, high concentration species can yield erroneous results if their ion intensities reach beyond the limits of the detection system, leading to distorted and non-ideal detector response (e.g. saturation), and largely precluding the calculation of accurate m/z and intensity values. Here we present an open source computational method to correct peaks above a defined intensity (saturated) threshold determined by the MS instrumentation such as the analog-to-digital converters or time-to-digital converters used in conjunction with time-of-flightmore » MS. Here, in this method, the isotopic envelope for each observed ion above the saturation threshold is compared to its expected theoretical isotopic distribution. The most intense isotopic peak for which saturation does not occur is then utilized to re-calculate the precursor m/z and correct the intensity, resulting in both higher mass accuracy and greater dynamic range. The benefits of this approach were evaluated with proteomic and lipidomic datasets of varying complexities. After correcting the high concentration species, reduced mass errors and enhanced dynamic range were observed for both simple and complex omic samples. Specifically, the mass error dropped by more than 50% in most cases for highly saturated species and dynamic range increased by 1–2 orders of magnitude for peptides in a blood serum sample.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tougaard, Sven
The author reports a systematic study of the range of validity of a previously developed algorithm for automated x-ray photoelectron spectroscopy analysis, which takes into account the variation in both peak intensity and the intensity in the background of inelastically scattered electrons. This test was done by first simulating spectra for the Au4d peak with gold atoms distributed in the form of a wide range of nanostructures, which includes overlayers with varying thickness, a 5 A layer of atoms buried at varying depths and a substrate covered with an overlayer of varying thickness. Next, the algorithm was applied to analyzemore » these spectra. The algorithm determines the number of atoms within the outermost 3 {lambda} of the surface. This amount of substance is denoted AOS{sub 3{lambda}} (where {lambda} is the electron inelastic mean free path). In general the determined AOS{sub 3{lambda}} is found to be accurate to within {approx}10-20% depending on the depth distribution of the atoms. The algorithm also determines a characteristic length L, which was found to give unambiguous information on the depth distribution of the atoms for practically all studied cases. A set of rules for this parameter, which relates the value of L to the depths where the atoms are distributed, was tested, and these rules were found to be generally valid with only a few exceptions. The results were found to be rather independent of the spectral energy range (from 20 to 40 eV below the peak energy) used in the analysis.« less
Rotational Acceleration during Head Impact Resulting from Different Judo Throwing Techniques
MURAYAMA, Haruo; HITOSUGI, Masahito; MOTOZAWA, Yasuki; OGINO, Masahiro; KOYAMA, Katsuhiro
2014-01-01
Most severe head injuries in judo are reported as acute subdural hematoma. It is thus necessary to examine the rotational acceleration of the head to clarify the mechanism of head injuries. We determined the rotational acceleration of the head when the subject is thrown by judo techniques. One Japanese male judo expert threw an anthropomorphic test device using two throwing techniques, Osoto-gari and Ouchigari. Rotational and translational head accelerations were measured with and without an under-mat. For Osoto-gari, peak resultant rotational acceleration ranged from 4,284.2 rad/s2 to 5,525.9 rad/s2 and peak resultant translational acceleration ranged from 64.3 g to 87.2 g; for Ouchi-gari, the accelerations respectively ranged from 1,708.0 rad/s2 to 2,104.1 rad/s2 and from 120.2 g to 149.4 g. The resultant rotational acceleration did not decrease with installation of an under-mat for both Ouchi-gari and Osoto-gari. We found that head contact with the tatami could result in the peak values of translational and rotational accelerations, respectively. In general, because kinematics of the body strongly affects translational and rotational accelerations of the head, both accelerations should be measured to analyze the underlying mechanism of head injury. As a primary preventative measure, throwing techniques should be restricted to participants demonstrating ability in ukemi techniques to avoid head contact with the tatami. PMID:24477065
Rotational acceleration during head impact resulting from different judo throwing techniques.
Murayama, Haruo; Hitosugi, Masahito; Motozawa, Yasuki; Ogino, Masahiro; Koyama, Katsuhiro
2014-01-01
Most severe head injuries in judo are reported as acute subdural hematoma. It is thus necessary to examine the rotational acceleration of the head to clarify the mechanism of head injuries. We determined the rotational acceleration of the head when the subject is thrown by judo techniques. One Japanese male judo expert threw an anthropomorphic test device using two throwing techniques, Osoto-gari and Ouchi-gari. Rotational and translational head accelerations were measured with and without an under-mat. For Osoto-gari, peak resultant rotational acceleration ranged from 4,284.2 rad/s(2) to 5,525.9 rad/s(2) and peak resultant translational acceleration ranged from 64.3 g to 87.2 g; for Ouchi-gari, the accelerations respectively ranged from 1,708.0 rad/s(2) to 2,104.1 rad/s(2) and from 120.2 g to 149.4 g. The resultant rotational acceleration did not decrease with installation of an under-mat for both Ouchi-gari and Osoto-gari. We found that head contact with the tatami could result in the peak values of translational and rotational accelerations, respectively. In general, because kinematics of the body strongly affects translational and rotational accelerations of the head, both accelerations should be measured to analyze the underlying mechanism of head injury. As a primary preventative measure, throwing techniques should be restricted to participants demonstrating ability in ukemi techniques to avoid head contact with the tatami.
Eolian additions to late Quaternary alpine soils, Indian Peaks Wilderness Area, Colorado Front Range
Muhs, D.R.; Benedict, J.B.
2006-01-01
Surface horizons of many alpine soils on Quaternary deposits in high-mountain settings are enriched in silt. The origin of these particles has been debated, particularly in the Rocky Mountain region of North America. The most common explanations are frost shattering of coarser particles and eolian additions from distant sources. We studied soil A horizons on alpine moraines of late-glacial (Satanta Peak) age in the Colorado Front Range. Surface horizons of soils on these moraines are enriched in silt and have a particle size distribution that resembles loess and dust deposits found elsewhere. The compositions of sand and silt fractions of the soils were compared to possible local source rocks, using immobile trace elements Ti, Nb, Zr, Ce, and Y. The sand fractions of soils have a wide range of trace element ratios, similar to the range of values in the local biotite gneiss bedrock. In contrast, silt fractions have narrower ranges of trace element ratios that do not overlap the range of these ratios in biotite gneiss. The particle size and geochemical results support an interpretation that silts in these soils are derived from airborne dust. Eolian silts were most likely derived from distant sources, such as the semiarid North Park and Middle Park basins to the west. We hypothesize that much of the eolian influx to soils of the Front Range occurred during an early to mid-Holocene warm period, when sediment availability in semiarid source basins was at a maximum.
NASA Astrophysics Data System (ADS)
Liu, Lei; Guo, Rui; Wu, Jun-an
2017-02-01
Crosstalk is a main factor for wrong distance measurement by ultrasonic sensors, and this problem becomes more difficult to deal with under Doppler effects. In this paper, crosstalk reduction with Doppler shifts on small platforms is focused on, and a fast echo matching algorithm (FEMA) is proposed on the basis of chaotic sequences and pulse coding technology, then verified through applying it to match practical echoes. Finally, we introduce how to select both better mapping methods for chaotic sequences, and algorithm parameters for higher achievable maximum of cross-correlation peaks. The results indicate the following: logistic mapping is preferred to generate good chaotic sequences, with high autocorrelation even when the length is very limited; FEMA can not only match echoes and calculate distance accurately with an error degree mostly below 5%, but also generates nearly the same calculation cost level for static or kinematic ranging, much lower than that by direct Doppler compensation (DDC) with the same frequency compensation step; The sensitivity to threshold value selection and performance of FEMA depend significantly on the achievable maximum of cross-correlation peaks, and a higher peak is preferred, which can be considered as a criterion for algorithm parameter optimization under practical conditions.
Graded nanowell arrays: a fine plasmonic "library" with an adjustable spectral range.
Xue, Peihong; Ye, Shunsheng; Su, Hongyang; Wang, Shuli; Nan, Jingjie; Chen, Xingchi; Ruan, Weidong; Zhang, Junhu; Cui, Zhanchen; Yang, Bai
2017-05-25
We present an effective approach for fabricating graded plasmonic arrays based on ordered micro-/nanostructures with a geometric gradient. Ag nanowell arrays with graded geometric parameters were fabricated and systematically investigated. The order of the graded plasmonic arrays is generated by colloidal lithography, while the geometric gradient is the result of inclined reactive ion etching. The surface plasmon resonance (SPR) peaks were measured at different positions, which move gradually along the Ag nanowell arrays with a geometric gradient. Such micro-/nanostructure arrays with graded and integrated SPR peaks can work as a fine plasmonic "library" (FPL), and the spectral range can be controlled using a "coarse adjustment knob" (lattice constant) and a "fine adjustment knob" (pore diameter). Additionally, the spectral resolution of the FPL is high, which benefits from the high value of the full height/full width at half-maximum and the small step size of the wavelength shift (0.5 nm). Meanwhile, the FPL could be effectively applied as a well-defined model to verify the plasmonic enhancement in surface enhanced Raman scattering. As the FPL is an integrated optical material with graded individual SPR peaks, it can not only be a theoretical model for fundamental research, but also has great potential in high-throughput screening of optical materials, multiplex sensors, etc.
NASA Astrophysics Data System (ADS)
Munoz, H.; Taheri, A.; Chanda, E. K.
2016-12-01
Brittleness is a fundamental mechanical rock property critical to many civil engineering works, mining development projects and mineral exploration operations. However, rock brittleness is a concept yet to be investigated as there is not any unique criterion available, widely accepted by rock engineering community able to describe rock brittleness quantitatively. In this study, new brittleness indices were developed based on fracture strain energy quantities obtained from the complete stress-strain characteristics of rocks. In doing so, different rocks having unconfined compressive strength values ranging from 7 to 215 MPa were examined in a series of quasi-static uniaxial compression tests after properly implementing lateral-strain control in a closed-loop system to apply axial load to rock specimen. This testing method was essential to capture post-peak regime of the rocks since a combination of class I-II or class II behaviour featured post-peak stress-strain behaviour. Further analysis on the post-peak strain localisation, stress-strain characteristics and the fracture pattern causing class I-II and class II behaviour were undertaken by analysing the development of field of strains in the rocks via three-dimensional digital image correlation. Analysis of the results demonstrated that pre-peak stress-strain brittleness indices proposed solely based on pre-peak stress-strain behaviour do not show any correlation with any of pre-peak rock mechanical parameters. On the other hand, the proposed brittleness indices based on pre-peak and post-peak stress-strain relations were found to competently describe an unambiguous brittleness scale against rock deformation and strength parameters such as the elastic modulus, the crack damage stress and the peak stress relevant to represent failure process.
Trommer, J.T.; Loper, J.E.; Hammett, K.M.
1996-01-01
Several traditional techniques have been used for estimating stormwater runoff from ungaged watersheds. Applying these techniques to water- sheds in west-central Florida requires that some of the empirical relationships be extrapolated beyond tested ranges. As a result, there is uncertainty as to the accuracy of these estimates. Sixty-six storms occurring in 15 west-central Florida watersheds were initially modeled using the Rational Method, the U.S. Geological Survey Regional Regression Equations, the Natural Resources Conservation Service TR-20 model, the U.S. Army Corps of Engineers Hydrologic Engineering Center-1 model, and the Environmental Protection Agency Storm Water Management Model. The techniques were applied according to the guidelines specified in the user manuals or standard engineering textbooks as though no field data were available and the selection of input parameters was not influenced by observed data. Computed estimates were compared with observed runoff to evaluate the accuracy of the techniques. One watershed was eliminated from further evaluation when it was determined that the area contributing runoff to the stream varies with the amount and intensity of rainfall. Therefore, further evaluation and modification of the input parameters were made for only 62 storms in 14 watersheds. Runoff ranged from 1.4 to 99.3 percent percent of rainfall. The average runoff for all watersheds included in this study was about 36 percent of rainfall. The average runoff for the urban, natural, and mixed land-use watersheds was about 41, 27, and 29 percent, respectively. Initial estimates of peak discharge using the rational method produced average watershed errors that ranged from an underestimation of 50.4 percent to an overestimation of 767 percent. The coefficient of runoff ranged from 0.20 to 0.60. Calibration of the technique produced average errors that ranged from an underestimation of 3.3 percent to an overestimation of 1.5 percent. The average calibrated coefficient of runoff for each watershed ranged from 0.02 to 0.72. The average values of the coefficient of runoff necessary to calibrate the urban, natural, and mixed land-use watersheds were 0.39, 0.16, and 0.08, respectively. The U.S. Geological Survey regional regression equations for determining peak discharge produced errors that ranged from an underestimation of 87.3 percent to an over- estimation of 1,140 percent. The regression equations for determining runoff volume produced errors that ranged from an underestimation of 95.6 percent to an overestimation of 324 percent. Regression equations developed from data used for this study produced errors that ranged between an underestimation of 82.8 percent and an over- estimation of 328 percent for peak discharge, and from an underestimation of 71.2 percent to an overestimation of 241 percent for runoff volume. Use of the equations developed for west-central Florida streams produced average errors for each type of watershed that were lower than errors associated with use of the U.S. Geological Survey equations. Initial estimates of peak discharges and runoff volumes using the Natural Resources Conservation Service TR-20 model, produced average errors of 44.6 and 42.7 percent respectively, for all the watersheds. Curve numbers and times of concentration were adjusted to match estimated and observed peak discharges and runoff volumes. The average change in the curve number for all the watersheds was a decrease of 2.8 percent. The average change in the time of concentration was an increase of 59.2 percent. The shape of the input dimensionless unit hydrograph also had to be adjusted to match the shape and peak time of the estimated and observed flood hydrographs. Peak rate factors for the modified input dimensionless unit hydrographs ranged from 162 to 454. The mean errors for peak discharges and runoff volumes were reduced to 18.9 and 19.5 percent, respectively, using the average calibrated input parameters for ea
Research on the range side lobe suppression method for modulated stepped frequency radar signals
NASA Astrophysics Data System (ADS)
Liu, Yinkai; Shan, Tao; Feng, Yuan
2018-05-01
The magnitude of time-domain range sidelobe of modulated stepped frequency radar affects the imaging quality of inverse synthetic aperture radar (ISAR). In this paper, the cause of high sidelobe in modulated stepped frequency radar imaging is analyzed first in real environment. Then, the chaos particle swarm optimization (CPSO) is used to select the amplitude and phase compensation factors according to the minimum sidelobe criterion. Finally, the compensated one-dimensional range images are obtained. Experimental results show that the amplitude-phase compensation method based on CPSO algorithm can effectively reduce the sidelobe peak value of one-dimensional range images, which outperforms the common sidelobe suppression methods and avoids the coverage of weak scattering points by strong scattering points due to the high sidelobes.
Correlation between toe flexor strength and ankle dorsiflexion ROM during the countermovement jump.
Yun, Sung Joon; Kim, Moon-Hwan; Weon, Jong-Hyuck; Kim, Young; Jung, Sung-Hoon; Kwon, Oh-Yun
2016-08-01
[Purpose] This study assessed the relationships between peak toe flexor muscle strength, ankle dorsiflexion range of motion, and countermovement jump height. [Subjects and Methods] Eighteen healthy volunteers participated in the study. Each participant completed tests for peak toe flexor muscle strength, ankle dorsiflexion range of motion, and countermovement jump height. [Results] The results showed (1) a moderate correlation between ankle dorsiflexion range of motion and countermovement jump height and (2) a high correlation between peak first toe flexor muscle strength and countermovement jump height. Peak first toe flexor muscle strength and ankle dorsiflexion range of motion are the main contributors to countermovement jump performance. [Conclusion] These findings indicate that the measurement of peak first toe flexor muscle strength and ankle dorsiflexion range of motion may be useful in clinical practice for improving jump performance in athletes training for sports such as volleyball and basketball.
[The Performance Analysis for Lighting Sources in Highway Tunnel Based on Visual Function].
Yang, Yong; Han, Wen-yuan; Yan, Ming; Jiang, Hai-feng; Zhu, Li-wei
2015-10-01
Under the condition of mesopic vision, the spectral luminous efficiency function is shown as a series of curves. Its peak wavelength and intensity are affected by light spectrum, background brightness and other aspects. The impact of light source to lighting visibility could not be carried out via a single optical parametric characterization. The reaction time of visual cognition is regard as evaluating indexes in this experiment. Under the condition of different speed and luminous environment, testing visual cognition based on vision function method. The light sources include high pressure sodium, electrodeless fluorescent lamp and white LED with three kinds of color temperature (the range of color temperature is from 1 958 to 5 537 K). The background brightness value is used for basic section of highway tunnel illumination and general outdoor illumination, its range is between 1 and 5 cd x m(-)2. All values are in the scope of mesopic vision. Test results show that: under the same condition of speed and luminance, the reaction time of visual cognition that corresponding to high color temperature of light source is shorter than it corresponding to low color temperature; the reaction time corresponding to visual target in high speed is shorter than it in low speed. At the end moment, however, the visual angle of target in observer's visual field that corresponding to low speed was larger than it corresponding to high speed. Based on MOVE model, calculating the equivalent luminance of human mesopic vision, which is on condition of different emission spectrum and background brightness that formed by test lighting sources. Compared with photopic vision result, the standard deviation (CV) of time-reaction curve corresponding to equivalent brightness of mesopic vision is smaller. Under the condition of mesopic vision, the discrepancy between equivalent brightness of different lighting source and photopic vision, that is one of the main reasons for causing the discrepancy of visual recognition. The emission spectrum peak of GaN chip is approximate to the wave length peak of efficiency function in photopic vision. The lighting visual effect of write LED in high color temperature is better than it in low color temperature and electrodeless fluorescent lamp. The lighting visual effect of high pressure sodium is weak. Because of its peak value is around the Na+ characteristic spectra.
A low noise and high precision linear power supply with thermal foldback protection.
Carniti, P; Cassina, L; Gotti, C; Maino, M; Pessina, G
2016-05-01
A low noise and high precision linear power supply was designed for use in rare event search experiments with macrobolometers. The circuit accepts at the input a "noisy" dual supply voltage up to ±15 V and gives at the output precise, low noise, and stable voltages that can be set between ±3.75 V and ±12.5 V in eight 1.25 V steps. Particular care in circuit design, component selection, and proper filtering results in a noise spectral density of 50nV/Hz at 1 Hz and 20nV/Hz white when the output is set to ±5 V. This corresponds to 125 nV RMS (0.8 μV peak to peak) between 0.1 Hz and 10 Hz, and 240 nV RMS (1.6 μV peak to peak) between 0.1 Hz and 100 Hz. The power supply rejection ratio (PSRR) of the circuit is 100 dB at low frequency, and larger than 40 dB up to high frequency, thanks to a proper compensation design. Calibration allows to reach a precision in the absolute value of the output voltage of ±70 ppm, or ±350 μV at ±5 V, and to reduce thermal drifts below ±1 ppm/(∘)C in the expected operating range. The maximum peak output current is about 6 A from each output. An original foldback protection scheme was developed that dynamically limits the maximum output current to keep the temperature of the output transistors within their safe operating range. An add-on card based on an ARM Cortex-M3 microcontroller is devoted to the monitoring and control of all circuit functionalities and provides remote communication via CAN bus.
Heavy-ion dominance near Cluster perigees
NASA Astrophysics Data System (ADS)
Ferradas, C. P.; Zhang, J.-C.; Kistler, L. M.; Spence, H. E.
2015-12-01
Time periods in which heavy ions dominate over H+ in the energy range of 1-40 keV were observed by the Cluster Ion Spectrometry (CIS)/COmposition DIstribution Function (CODIF) instrument onboard Cluster Spacecraft 4 at L values less than 4. The characteristic feature is a narrow flux peak at around 10 keV that extends into low L values, with He+ and/or O+ dominating. In the present work we perform a statistical study of these events and examine their temporal occurrence and spatial distribution. The observed features, both the narrow energy range and the heavy-ion dominance, can be interpreted using a model of ion drift from the plasma sheet, subject to charge exchange losses. The narrow energy range corresponds to the only energy range that has direct drift access from the plasma sheet during quiet times. The drift time to these locations from the plasma sheet is > 30 h, so that charge exchange has a significant impact on the population. We show that a simple drift/loss model can explain the dependence on L shell and MLT of these heavy-ion-dominant time periods.
Lyu, Yan; Zhang, Kai; Chai, Fahe; Cheng, Tiantao; Yang, Qing; Zheng, Zilong; Li, Xiang
2017-05-01
This study examines size-resolved heavy metal data for particles sampled near an urban site affected by non-ferrous metal smelting in China with a focus on how particle sizes impact regional respiratory deposition behavior. Particles with aerodynamic diameters between 0.43 and 9 μm were collected during winter haze episodes from December 2011 to January 2012. The results showed that concentrations of individual trace elements ranged from ∼10 -2 -∼10 4 ng/m 3 . Mass size distributions exhibit that Cu, Zn, As, Se, Ag, Cd, TI, and Pb have unimodal peak in fine particles range (<2.1 μm); Al, Ti, Fe, Sr, Cr, Co, Ni, Mo, and U have unimodal peak in coarse range (>2.1 μm), and Be, Na, Mg, Ca, Ba, Th, V, Mn, Sn, Sb, and K have bimodal profiles with a dominant peak in the fine range and a smaller peak in the coarse range. The total deposition fluxes of trace elements were estimated at 2.1 × 10 -2 - 4.1 × 10 3 ng/h by the MPPD model, and the region with the highest contribution was the head region (42% ± 13%), followed by the tracheobronchial region (11% ± 3%) and pulmonary region (6% ± 1%). The daily intake of individual element for humans occurs via three main exposure pathways: ingestion (2.3 × 10 -4 mg/kg/day), dermal contact (2.3 × 10 -5 mg/kg/day), and inhalation (9.0 × 10 -6 mg/kg/day). A further health risk assessment revealed that the risk values for humans were all above the guidelines of the hazard quotient (1) and cancer risk (10 -6 ), indicating that there are potential non-cancer effects and cancer risks in this area. Copyright © 2017 Elsevier Ltd. All rights reserved.
RoboPol: the optical polarization of gamma-ray-loud and gamma-ray-quiet blazars
NASA Astrophysics Data System (ADS)
Angelakis, E.; Hovatta, T.; Blinov, D.; Pavlidou, V.; Kiehlmann, S.; Myserlis, I.; Böttcher, M.; Mao, P.; Panopoulou, G. V.; Liodakis, I.; King, O. G.; Baloković, M.; Kus, A.; Kylafis, N.; Mahabal, A.; Marecki, A.; Paleologou, E.; Papadakis, I.; Papamastorakis, I.; Pazderski, E.; Pearson, T. J.; Prabhudesai, S.; Ramaprakash, A. N.; Readhead, A. C. S.; Reig, P.; Tassis, K.; Urry, M.; Zensus, J. A.
2016-12-01
We present average R-band optopolarimetric data, as well as variability parameters, from the first and second RoboPol observing season. We investigate whether gamma-ray-loud and gamma-ray-quiet blazars exhibit systematic differences in their optical polarization properties. We find that gamma-ray-loud blazars have a systematically higher polarization fraction (0.092) than gamma-ray-quiet blazars (0.031), with the hypothesis of the two samples being drawn from the same distribution of polarization fractions being rejected at the 3σ level. We have not found any evidence that this discrepancy is related to differences in the redshift distribution, rest-frame R-band luminosity density, or the source classification. The median polarization fraction versus synchrotron-peak-frequency plot shows an envelope implying that high-synchrotron-peaked sources have a smaller range of median polarization fractions concentrated around lower values. Our gamma-ray-quiet sources show similar median polarization fractions although they are all low-synchrotron-peaked. We also find that the randomness of the polarization angle depends on the synchrotron peak frequency. For high-synchrotron-peaked sources, it tends to concentrate around preferred directions while for low-synchrotron-peaked sources, it is more variable and less likely to have a preferred direction. We propose a scenario which mediates efficient particle acceleration in shocks and increases the helical B-field component immediately downstream of the shock.
Shobugawa, Yugo; Wiafe, Seth A; Saito, Reiko; Suzuki, Tsubasa; Inaida, Shinako; Taniguchi, Kiyosu; Suzuki, Hiroshi
2012-06-19
Annual influenza epidemics occur worldwide resulting in considerable morbidity and mortality. Spreading pattern of influenza is not well understood because it is often hampered by the quality of surveillance data that limits the reliability of analysis. In Japan, influenza is reported on a weekly basis from 5,000 hospitals and clinics nationwide under the scheme of the National Infectious Disease Surveillance. The collected data are available to the public as weekly reports which were summarized into number of patient visits per hospital or clinic in each of the 47 prefectures. From this surveillance data, we analyzed the spatial spreading patterns of influenza epidemics using weekly weighted standard distance (WSD) from the 1999/2000 through 2008/2009 influenza seasons in Japan. WSD is a single numerical value representing the spatial compactness of influenza outbreak, which is small in case of clustered distribution and large in case of dispersed distribution. We demonstrated that the weekly WSD value or the measure of spatial compactness of the distribution of reported influenza cases, decreased to its lowest value before each epidemic peak in nine out of ten seasons analyzed. The duration between the lowest WSD week and the peak week of influenza cases ranged from minus one week to twenty weeks. The duration showed significant negative association with the proportion of influenza A/H3N2 cases in early phase of each outbreak (correlation coefficient was -0.75, P = 0.012) and significant positive association with the proportion of influenza B cases in the early phase (correlation coefficient was 0.64, P = 0.045), but positively correlated with the proportion of influenza A/H1N1 strain cases (statistically not significant). It is assumed that the lowest WSD values just before influenza peaks are due to local outbreak which results in small standard distance values. As influenza cases disperse nationwide and an epidemic reaches its peak, WSD value changed to be a progressively increasing. The spatial distribution of nationwide influenza outbreak was measured by using a novel WSD method. We showed that spreading rate varied by type and subtypes of influenza virus using WSD as a spatial indicator. This study is the first to show a relationship between influenza epidemic trend by type/subtype and spatial distribution of influenza nationwide in Japan.
Frequency response of portable PEF meters.
Hankinson, J L; Das, M K
1995-08-01
Peak expiratory flow (PEF) is a dynamic parameter and therefore requires a measuring device with a high-frequency response. This study evaluated the frequency-response characteristics of eight commercially available PEF meters, using simulated forced-expiratory maneuvers with a computer-controlled mechanical pump. Three different PEF levels were used (200, 400, and 600 L/min) at six levels of harmonic-frequency content similar to those observed in human subjects. For waveforms with higher frequency content (at the high end or above the physiologic range), the Assess, Vitalograph, Pocket Peak, and Spir-O-Flow PEF meters all overread PEF (greater than 15% difference from target values) at all three PEF levels. These results suggest that the frequency response of PEF meters is an important consideration in the selection of such meters and should be included in device requirements. The current practice of using various levels of American Thoracic Society (ATS) waveform 24 with its low-frequency content may not adequately evaluate the frequency characteristics of PEF meters. An upper range (5% of the fundamental frequency) of 12 Hz, within the range observed in normal subjects, appears to be more practical than an upper limit of 20 Hz.
Use of real-time sensors to characterise human exposures to combustion related pollutants.
Delgado-Saborit, Juana Maria
2012-07-01
Concentrations of black carbon and nitrogen dioxide have been collected concurrently using a MicrAeth AE-51 and an Aeroqual GSS NO(2) sensor. Forty five sampling events with a duration spanning between 16 and 22 hours have collected 10,800 5 min data in Birmingham (UK) from July to October 2011. The high temporal resolution database allowed identification of peak exposures and which activities contributed the most to these peaks, such as cooking and commuting. Personal exposure concentrations for non-occupationally exposed subjects ranged between 0.01 and 50 μg m(-3) for BC with average values of 1.3 ± 2.2 μg m(-3) (AM ± SD). Nitrogen dioxide exposure concentrations were in the range
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arapov, Yu. G.; Gudina, S. V.; Klepikova, A. S., E-mail: klepikova@imp.uran.ru
2017-02-15
The dependences of the longitudinal and Hall resistances on a magnetic field in n-InGaAs/GaAs heterostructures with a single and double quantum wells after infrared illumination are measured in the range of magnetic fields Ð’ = 0–16 T and temperatures T = 0.05–4.2 K. Analysis of the experimental results was carried out on a base of two-parameter scaling hypothesis for the integer quantum Hall effect. The value of the second (irrelevant) critical exponent of the theory of two-parameter scaling was estimated.
NASA Astrophysics Data System (ADS)
Yu, Xin; Dong, Lizhi; Lai, Boheng; Yang, Ping; Wang, Shuai; Wang, Xun; Liu, Yong; Tang, Guomao; Xu, Bing
2017-11-01
In order to solve the problem of large low-order aberrations with solid-state zigzag slab lasers, an automatic compensator has been developed in this paper. In this compensator, three lenses are mounted on a motorized rail, whose positions can be obtained using ray tracing method based on the beam parameters detected by a wave-front sensor. The initial peak to valley (PV) values of the wave-front range up to several tens of microns. Both simulated and experimental results show that the PV values of the wave-front can be reduced to around 1 . 6 μm with the proposed automatic compensator.
SU-E-T-146: Beam Energy Spread Estimate Based On Bragg Peak Measurement
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anferov, V; Derenchuk, V; Moore, R
2015-06-15
Purpose: ProNova is installing and commissioning a two room proton therapy system in Knoxville, TN. Beam energy out of the 230MeV cyclotron was measured on Jan 24, 2015. Cyclotron beam was delivered into a Zebra multi layered IC detector calibrated in terms of penetration range in water. The analysis of the measured Bragg peak determines penetration range in water which can be subsequently converted into proton beam energy. We extended this analysis to obtain an estimate of the beam energy spread out of the cyclotron. Methods: Using Monte Carlo simulations we established the correlation between Bragg peak shape parameters (widthmore » at 50% and 80% dose levels, distal falloff) and penetration range for a monoenergetic proton beam. For large uniform field impinging on a small area detector, we observed linear dependence of each Bragg peak parameter on beam penetration range as shown in Figure A. Then we studied how this correlation changes when the shape of Bragg peak is distorted by the beam focusing conditions. As shown in Figure B, small field size or diverging beam cause Bragg peak deformation predominantly in the proximal region. The distal shape of the renormalized Bragg peaks stays nearly constant. This excludes usage of Bragg peak width parameters for energy spread estimates. Results: The measured Bragg peaks had an average distal falloff of 4.86mm, which corresponds to an effective range of 35.5cm for a monoenergetic beam. The 32.7cm measured penetration range is 2.8cm less. Passage of a 230MeV proton beam through a 2.8cm thick slab of water results in a ±0.56MeV energy spread. As a final check, we confirmed agreement between shapes of the measured Bragg peak and one generated by Monte-Carlo code for proton beam with 0.56 MeV energy spread. Conclusion: Proton beam energy spread can be estimated using Bragg peak analysis.« less
NASA Astrophysics Data System (ADS)
Madurell, T.; Fanelli, E.; Cartes, J. E.
Stable isotope (δ 13C and δ 15N) analyses were performed on suprabenthic fauna collected in the western Mediterranean (NW Balearic Islands), at depths ranging between 350 and 780 m. Samples were collected seasonally at bi-monthly intervals during six cruises performed between August 2003 and June 2004, using a Macer-GIROQ suprabenthic sledge (0.5 mm mesh size). Twenty-four separate species (5 mysids, 12 amphipods, 2 cumaceans, 2 isopods, 1 euphausiid, 1 decapod and 1 fish) and bulk copepods were analyzed on a seasonal basis for stable carbon and nitrogen isotopes. Stable nitrogen isotope ratios (δ 15N) ranged from 2.3‰ (the amphipod Lepechinella manco in September 2003) to 13.0‰ (the amphipod Rhachotropis caeca in August 2003). δ 13C values ranged from - 24.2 (the cumacean Campylaspis sulcata in June 2004) to - 16.1 (the amphipod Bruzelia typica in November 2006). Both δ 13C and δ 15N values suggest that there are three trophic levels within the suprabenthic community. However, considering the bathymetric range of the species, the results suggest that the deepest assemblage supported only two trophic levels. The stable isotope ratios of suprabenthic fauna displayed a continuum of values and confirmed a wide spectrum of feeding types (from filter-feeders to predators). In general, and in spite of the poor knowledge about diets available for most suprabenthic species, higher δ 15N were found for carnivorous amphipods (e.g. Rhachotropis spp., Nicippe tumida) consuming copepods. Low overlap for δ 13C and δ 15N values was observed, though δ 15N values where less variable than δ 13C, which suggests high resource partitioning in this assemblage. Seasonal variations in isotopic composition for both δ 13C and δ 15N were low (less than 1‰ and 3‰, respectively) and variable depending on species. Low correlations between δ 13C and δ 15N of suprabenthic fauna were found for all periods studied, though increasing from February 2004 to June 2004 (after the main peak of primary production in surface). C:N ratio (indicator of lipid content) showed higher values in summer than in winter. This suggests that lipid content may explain the seasonal patterns of δ 13C variability and, due to the increase of storage products in phytoplankton and zooplankton, it possibly indicates the peak of primary production at the surface.
Column Chromatography To Obtain Organic Cation Sorption Isotherms.
Jolin, William C; Sullivan, James; Vasudevan, Dharni; MacKay, Allison A
2016-08-02
Column chromatography was evaluated as a method to obtain organic cation sorption isotherms for environmental solids while using the peak skewness to identify the linear range of the sorption isotherm. Custom packed HPLC columns and standard batch sorption techniques were used to intercompare sorption isotherms and solid-water sorption coefficients (Kd) for four organic cations (benzylamine, 2,4-dichlorobenzylamine, phenyltrimethylammonium, oxytetracycline) with two aluminosilicate clay minerals and one soil. A comparison of Freundlich isotherm parameters revealed isotherm linearity or nonlinearity was not significantly different between column chromatography and traditional batch experiments. Importantly, skewness (a metric of eluting peak symmetry) analysis of eluting peaks can establish isotherm linearity, thereby enabling a less labor intensive means to generate the extensive data sets of linear Kd values required for the development of predictive sorption models. Our findings clearly show that column chromatography can reproduce sorption measures from conventional batch experiments with the benefit of lower labor-intensity, faster analysis times, and allow for consistent sorption measures across laboratories with distinct chromatography instrumentation.
Lei, Chengxin; Chen, Leyi; Tang, Zhixiong; Li, Daoyong; Cheng, Zhenzhi; Tang, Shaolong; Du, Youwei
2016-02-15
The properties of optics and magneto-optical Faraday effects in a metal-dielectric tri-layer structure with subwavelength rectangular annular arrays are investigated. It is noteworthy that we obtained the strongly enhanced Faraday rotation of the desired sign along with high transmittance by optimizing the parameters of the nanostructure in the visible spectral ranges. In this system, we obtained two extraordinary optical transmission (EOT) resonant peaks with enhanced Faraday rotations, whose signs are opposite, which may provide the possibility of designing multi-channel magneto-optical devices. Study results show that the maximum of the figure of merit (FOM) of the structure can be obtained between two EOT resonant peaks accompanied by an enhanced Faraday rotation. The positions of the maximum value of the FOM and resonant peaks of transmission along with a large Faraday rotation can be tailored by simply adjusting the geometric parameters of our models. These research findings are of great importance for future applications of magneto-optical devices.
Graded Exercise Testing in a Pediatric Weight Management Center: The DeVos Protocol.
Eisenmann, Joey C; Guseman, Emily Hill; Morrison, Kyle; Tucker, Jared; Smith, Lucie; Stratbucker, William
2015-12-01
In this article, we describe a protocol used to test the functional capacity of the obese pediatric patient and describe the peak oxygen consumption (VO2peak) of patients seeking treatment at a pediatric weight management center. One hundred eleven (mean age, 12.5 ± 3.0 years) patients performed a multistage exercise test on a treadmill, of which 90 (81%) met end-test criteria and provided valid VO2peak data. Peak VO2 was expressed: (1) in absolute terms (L·min(-1)); (2) as the ratio of the volume of oxygen consumed per minute relative to total body mass (mL·kg(-1)·min(-1)); and (3) as the ratio of the volume of oxygen consumed per minute relative to fat-free mass (mL·FFM·kg(-1)·min(-1)). Mean BMI z-score was 2.4 ± 0.3 and the mean percent body fat was 36.5 ± 9.7%. Absolute VO2peak (L·min(-1)) was significantly different between sexes; however, relative values were similar between sexes. Mean VO2peak was 25.7 ± 4.8 mL·kg(-1)·min(-1) with a range of 13.5-36.7 mL·kg(-1)·min(-1). Obese youth seeking treatment at a stage 3 pediatric weight management center exhibit low VO2peak. The protocol outlined here should serve as a model for similar programs interested in the submaximal and peak responses to exercise in obese pediatric patients.
Cortigiani, Lauro; Sorbo, Simone; Miccoli, Mario; Scali, Maria Chiara; Simioniuc, Anca; Morrone, Doralisa; Bovenzi, Francesco; Marzilli, Mario; Dini, Frank Lloyd
2017-02-01
Cardiac power output to left ventricular mass (power/mass) is an index of myocardial efficiency reflecting the rate at which cardiac work is delivered with respect to the potential energy stored in the left ventricular mass. In the present study, we sought to investigate the capability of power/mass assessed at peak of dobutamine stress echocardiography to predict mortality in patients with ischaemic cardiomyopathy and no inducible ischaemia. One-hundred eleven patients (95 males; age 68 ± 10 years) with 35 ± 7% mean left ventricular ejection fraction and a dobutamine stress echocardiography (up to 40 µg/kg/min) negative by wall motion criteria formed the study population. Power/mass at peak stress was obtained as the product of a constant (K = 2.22 × 10 -1 ) with cardiac output and the mean arterial pressure divided by left ventricular mass to convert the units to W/100 g. Patients were followed up for a median of 29 months (inter-quartile range 16-72 months). All-cause mortality was the only accepted clinical end point. Mean peak-stress power/mass was 0.70 ± 0.31 W/100 g. During follow-up, 29 deaths (26%) were registered. With a receiver operating characteristic analysis, a peak-stress power/mass ≤0.50 W/100 g [area under curve 0.72 (95% CI 0.63; 0.80), sensitivity 59%, specificity 80%] was the best value for predicting mortality. Univariate prognostic indicators were age, male sex, peak-stress ejection fraction, peak-stress stroke volume, peak-stress cardiac output, peak-stress cardiac power output ≤1.48 W, and peak-stress power/mass ≤0.50 W/100 g. At multivariate analysis, age (HR 1.08, 95% CI 1.04; 1.14; P = 0.004) and peak-stress power/mass ≤0.50 W/100 g (HR 4.05, 95% CI 1.36; 12.00; P = 0.01) provided independent prognostic information. Three-year mortality was 14% in patients with peak-stress power/mass >0.50 W/100 g and 47% in those with peak-stress power/mass ≤0.50 W/100 g (log-rank 20.4; P < 0.0001). Power/mass assessed at peak of dobutamine stress echocardiography allows effective prognostication in patients with ischaemic cardiomyopathy and test result negative by wall motion criteria. In particular, a peak-stress power/mass ≤50 W/100 g is a strong and multivariable predictor of mortality. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.
Spatial variability of soil 137Cs in the South Caspian region.
Khoshbinfar, Soheil; Vahabi Moghaddam, Masoud
2012-05-01
In a comprehensive program of environmental radioactivity survey in South Caspian region, (137)Cs inventories in soil has been measured at more than 50 sites in the Iranian northern province of Guilan. This has been the first wide-range survey of soil radionuclide inventories in the narrow band sensitive ecosystem of south Caspian shore. Radioactivity measurements were carried out using HPGe gamma-spectrometry system. The activity concentration of (137)Cs in surface soil exhibits a mean value of 17.6 ± 9.4 Bq kg(-1), with a range of 2.3-41.7 Bq kg(-1). In many sites, split-level sampling method has been applied down to a depth of 20 cm. There were found generally two profiles. Most profiles exhibit a negative exponential distribution, while others revealed a clear subsurface peak in 5-10-cm layer. Cesium deposition in the study area has been estimated to be in the range of 0.38-2.9 kBq m(-2) with a mean value of 1.7 kBq m(-2). Distribution patterns of (137)Cs concentration levels and deposition values have been estimated using Kriging interpolation method. Observed hotspots in deposition pattern coincide with areas of higher precipitation.
Storms and flooding in California in December 2005 and January 2006 - a preliminary assessment
Parrett, Charles; Hunrichs, Richard A.
2006-01-01
A series of storms beginning before Christmas 2005 and ending after New Year's Day 2006 produced significant runoff over much of northern California. The storms resulted in an estimated $300 million in damages and Federal disaster declarations in 10 counties. Several precipitation stations in the Sierra Nevada had precipitation totals greater than 20 inches for the period December 24 through January 3, and several stations in the Coastal Range had precipitation totals greater than 18 inches. The peak stream discharges resulting from the storms in the north coast area generally had recurrence intervals in the 10- to 25-year range, although the recurrence interval for peak discharge at one station on Sonoma Creek near Agua Caliente was greater than 100 years. In the San Francisco Bay area, peak discharges also generally had recurrence intervals in the 10- to 25-year range. Further south along the central coast and in southern California, peak discharges had smaller recurrence intervals, in the 2- to 5-year range. Upper Sacramento River tributaries draining from the west had peak flows with recurrence intervals in the 2- to 5-year range, whereas upper tributaries draining from the east side had recurrence intervals in the 5- to 10-year range. Further south, Sacramento River tributaries such as the Yuba and American Rivers had peak discharges with recurrence intervals in the 10- to 25-year range. On the east side of the central Sierra around Lake Tahoe, peak discharges had recurrence intervals in the 10- to 25-year range. Further south in the Sierra, streams draining into the San Joaquin River Basin had flows with recurrence intervals ranging from 2 to 5 years.
MEDOF - MINIMUM EUCLIDEAN DISTANCE OPTIMAL FILTER
NASA Technical Reports Server (NTRS)
Barton, R. S.
1994-01-01
The Minimum Euclidean Distance Optimal Filter program, MEDOF, generates filters for use in optical correlators. The algorithm implemented in MEDOF follows theory put forth by Richard D. Juday of NASA/JSC. This program analytically optimizes filters on arbitrary spatial light modulators such as coupled, binary, full complex, and fractional 2pi phase. MEDOF optimizes these modulators on a number of metrics including: correlation peak intensity at the origin for the centered appearance of the reference image in the input plane, signal to noise ratio including the correlation detector noise as well as the colored additive input noise, peak to correlation energy defined as the fraction of the signal energy passed by the filter that shows up in the correlation spot, and the peak to total energy which is a generalization of PCE that adds the passed colored input noise to the input image's passed energy. The user of MEDOF supplies the functions that describe the following quantities: 1) the reference signal, 2) the realizable complex encodings of both the input and filter SLM, 3) the noise model, possibly colored, as it adds at the reference image and at the correlation detection plane, and 4) the metric to analyze, here taken to be one of the analytical ones like SNR (signal to noise ratio) or PCE (peak to correlation energy) rather than peak to secondary ratio. MEDOF calculates filters for arbitrary modulators and a wide range of metrics as described above. MEDOF examines the statistics of the encoded input image's noise (if SNR or PCE is selected) and the filter SLM's (Spatial Light Modulator) available values. These statistics are used as the basis of a range for searching for the magnitude and phase of k, a pragmatically based complex constant for computing the filter transmittance from the electric field. The filter is produced for the mesh points in those ranges and the value of the metric that results from these points is computed. When the search is concluded, the values of amplitude and phase for the k whose metric was largest, as well as consistency checks, are reported. A finer search can be done in the neighborhood of the optimal k if desired. The filter finally selected is written to disk in terms of drive values, not in terms of the filter's complex transmittance. Optionally, the impulse response of the filter may be created to permit users to examine the response for the features the algorithm deems important to the recognition process under the selected metric, limitations of the filter SLM, etc. MEDOF uses the filter SLM to its greatest potential, therefore filter competence is not compromised for simplicity of computation. MEDOF is written in C-language for Sun series computers running SunOS. With slight modifications, it has been implemented on DEC VAX series computers using the DEC-C v3.30 compiler, although the documentation does not currently support this platform. MEDOF can also be compiled using Borland International Inc.'s Turbo C++ v1.0, but IBM PC memory restrictions greatly reduce the maximum size of the reference images from which the filters can be calculated. MEDOF requires a two dimensional Fast Fourier Transform (2DFFT). One 2DFFT routine which has been used successfully with MEDOF is a routine found in "Numerical Recipes in C: The Art of Scientific Programming," which is available from Cambridge University Press, New Rochelle, NY 10801. The standard distribution medium for MEDOF is a .25 inch streaming magnetic tape cartridge (Sun QIC-24) in UNIX tar format. MEDOF was developed in 1992-1993.
The Frequency of Fitness Peak Shifts Is Increased at Expanding Range Margins Due to Mutation Surfing
Burton, Olivia J.; Travis, Justin M. J.
2008-01-01
Dynamic species' ranges, those that are either invasive or shifting in response to environmental change, are the focus of much recent interest in ecology, evolution, and genetics. Understanding how range expansions can shape evolutionary trajectories requires the consideration of nonneutral variability and genetic architecture, yet the majority of empirical and theoretical work to date has explored patterns of neutral variability. Here we use forward computer simulations of population growth, dispersal, and mutation to explore how range-shifting dynamics can influence evolution on rugged fitness landscapes. We employ a two-locus model, incorporating sign epistasis, and find that there is an increased likelihood of fitness peak shifts during a period of range expansion. Maladapted valley genotypes can accumulate at an expanding range front through a phenomenon called mutation surfing, which increases the likelihood that a mutation leading to a higher peak will occur. Our results indicate that most peak shifts occur close to the expanding front. We also demonstrate that periods of range shifting are especially important for peak shifting in species with narrow geographic distributions. Our results imply that trajectories on rugged fitness landscapes can be modified substantially when ranges are dynamic. PMID:18505864
Liu, Yinglin; Liu, Yukun; Li, Xuejiao; Jiao, Xuedan; Zhang, Rui; Zhang, Jianping
2016-10-01
To examine peak serum levels of the β-subunit of human chorionic gonadotropin (β-hCG) for prediction of early pregnancy outcomes among women with recurrent spontaneous abortion (RSA). In a retrospective study, the medical records of pregnant women with a history of RSA treated at Sun Yat-sen Memorial Hospital, China, between January 2011 and July 2013 were reviewed. Serum β-hCG had been measured twice weekly from 5 to 13weeks of pregnancy, and pregnancy was monitored by transvaginal ultrasonography to 13(+6)weeks. Optimal cutoff for peak β-hCG level was determined by receiver operator characteristic curve analysis and Youden index. Women were divided into four groups on the basis of optimal peak β-hCG cutoff and pregnancy outcome (pregnancy at 13weeks or spontaneous abortion). Peak β-hCG levels and length of pregnancy at this peak were examined. Overall, 1240 patients were included. The optimal cutoff value of peak β-hCG was 88 468IU/L, with a sensitivity, specificity, positive predictive value, and negative predictive value for successful pregnancy of 95.6%, 88.0%, 95.6%, and 89.0%, respectively. A faster rise in β-hCG, higher peak β-hCG, and longer pregnancy length at peak β-hCG were associated with successful early pregnancy. A cutoff value of serum β-hCG of 88 000IU/L could be used to predict early pregnancy outcomes for women with a history of RSA. Copyright © 2016. Published by Elsevier Ireland Ltd.
50 KW Class Krypton Hall Thruster Performance
NASA Technical Reports Server (NTRS)
Jacobson, David T.; Manzella, David H.
2003-01-01
The performance of a 50-kilowatt-class Hall thruster designed for operation on xenon propellant was measured using kryton propellant. The thruster was operated at discharge power levels ranging from 6.4 to 72.5 kilowatts. The device produced thrust ranging from 0.3 to 2.5 newtons. The thruster was operated at discharge voltages between 250 and 1000 volts. At the highest anode mass flow rate and discharge voltage and assuming a 100 percent singly charged condition, the discharge specific impulse approached the theoretical value. Discharge specific impulse of 4500 seconds was demonstrated at a discharge voltage of 1000 volts. The peak discharge efficiency was 64 percent at 650 volts.
Tide-surge historical assessment of extreme water levels for the St. Johns River: 1928-2017
NASA Astrophysics Data System (ADS)
Bacopoulos, Peter
2017-10-01
An historical storm population is developed for the St. Johns River, located in northeast Florida-US east coast, via extreme value assessment of an 89-year-long record of hourly water-level data. Storm surge extrema and the corresponding (independent) storm systems are extracted from the historical record as well as the linear and nonlinear trends of mean sea level. Peaks-over-threshold analysis reveals the top 16 most-impactful (storm surge) systems in the general return-period range of 1-100 years. Hurricane Matthew (2016) broke the record with a new absolute maximum water level of 1.56 m, although the peak surge occurred during slack tide level (0.00 m). Hurricanes and tropical systems contribute to return periods of 10-100 years with water levels in the approximate range of 1.3-1.55 m. Extratropical systems and nor'easters contribute to the historical storm population (in the general return-period range of 1-10 years) and are capable of producing extreme storm surges (in the approximate range of 1.15-1.3 m) on par with those generated by hurricanes and tropical systems. The highest astronomical tide is 1.02 m, which by evaluation of the historical record can contribute as much as 94% to the total storm-tide water level. Statically, a hypothetical scenario of Hurricane Matthew's peak surge coinciding with the highest astronomical tide would yield an overall storm-tide water level of 2.58 m, corresponding to an approximate 1000-year return period by historical comparison. Sea-level trends (linear and nonlinear) impact water-level return periods and constitute additional risk hazard for coastal engineering designs.
Testing the E(sub peak)-E(sub iso) Relation for GRBs Detected by Swift and Suzaku-WAM
NASA Technical Reports Server (NTRS)
Krimm, H. A.; Yamaoka, K.; Sugita, S.; Ohno, M.; Sakamoto, T.; Barthelmy, S. D.; Gehrels, N.; Hara, R.; Onda, K.; Sato, G.;
2009-01-01
One of the most prominent, yet controversial associations derived from the ensemble of prompt-phase observations of gamma-ray bursts (GRBs) is the apparent correlation in the source frame between the peak energy (E(sub peak)) of the nuF(nu) spectrum and the isotropic radiated energy, E(sub iso). Since most gamma-ray bursts (GRBs) have E(sub peak) above the energy range (15-150 keV) of the Burst Alert Telescope (BAT) on Swift, determining accurate E(sub peak) values for large numbers of Swift bursts has been difficult. However, by combining data from Swift/BAT and the Suzaku Wide-band All-Sky Monitor (WAM), which covers the energy range from 50-5000 keV, for bursts which are simultaneously detected ; one can accurately fit E(sub peak) and E(sub iso) and test the relationship between them for the Swift sample. Between the launch of Suzaku in July 2005 and the end of March 2009, there were 45 gamma-ray bursts (GRBs) which triggered both Swift/BAT and WAM and an additional 47 bursts which triggered Swift and were detected by WAM, but did not trigger. A BAT-WAM team has cross-calibrated the two instruments using GRBs, and we are now able to perform joint fits on these bursts to determine spectral parameters. For those bursts with spectroscopic redshifts.. we can also calculate the isotropic energy. Here we present the results of joint Swift/BAT-Suzaku/WAM spectral fits for 86 of the bursts detected by the two instruments. We show that the distribution of spectral fit parameters is consistent with distributions from earlier missions and confirm that Swift, bursts are consistent with earlier reported relationships between Epeak and isotropic energy. We show through time-resolved spectroscopy that individual burst pulses are also consistent with this relationship.
Lyα vs. fundamental properties of galaxies
NASA Astrophysics Data System (ADS)
Wofford, Aida; Leitherer, Claus; Salzer, John; COS Science Team
2013-03-01
We obtained HST COS Lyα spectroscopy for 20 galaxies that were Hα-selected from the Kitt Peak International Spectroscopic Survey data release. We cover redshifts of z=0.02-0.06 and a broad range in metallicity, reddening, and luminosity. We investigate correlations between the properties of the Lyα-lines and fundamental properties of the galaxies. Our seven emitters have: equivalent widths in the range EW(Lyα)=1-12 Å, i.e., below the completeness limits of higher redshift studies; extinction corrected Lyα/Hα ratios of at most 12-15% of the case B recombination theory value; and O I λ1302 ISM absorptions blueshifted to
Lunt, Heather; Roiz De Sa, Daniel; Roiz De Sa, Julia; Allsopp, Adrian
2013-07-01
To provide an accurate estimate of peak oxygen uptake (VO2 peak) for British Royal Navy Personnel aged between 18 and 39, comparing a gold standard treadmill based maximal exercise test with a submaximal one-mile walk test. Two hundred military personnel consented to perform a treadmill-based VO2 peak test and two one-mile walk tests round an athletics track. The estimated VO2 peak values from three different one-mile walk equations were compared to directly measured VO2 peak values from the treadmill-based test. One hundred participants formed a validation group from which a new equation was derived and the other 100 participants formed the cross-validation group. Existing equations underestimated the VO2 peak values of the fittest personnel and overestimated the VO2 peak of the least aerobically fit by between 2% and 18%. The new equation derived from the validation group has less bias, the highest correlation with the measured values (r = 0.83), and classified the most people correctly according to the Royal Navy's Fitness Test standards, producing the fewest false positives and false negatives combined (9%). The new equation will provide a more accurate estimate of VO2 peak for a British military population aged 18 to 39. Reprint & Copyright © 2013 Association of Military Surgeons of the U.S.
NASA Astrophysics Data System (ADS)
Dawande, Kiran; Patel, Swarnim; Bajpai, Rakesh; Keller, J. M.
2018-05-01
Thermally stimulated discharge currents in PVFO: PVDF blend samples of weight percentage ratio 80:20 and 95:05 prepared by the solution cast technique have been studied as function of polarizing temperature. Three distinct peaks are found at 60±10, 100±10, and 140 ±10 °C respectively. Activation energy values been calculated by initial rise method and it were found to range from 0.22 to 1.0 eV.
Smelter, Andrey; Rouchka, Eric C; Moseley, Hunter N B
2017-08-01
Peak lists derived from nuclear magnetic resonance (NMR) spectra are commonly used as input data for a variety of computer assisted and automated analyses. These include automated protein resonance assignment and protein structure calculation software tools. Prior to these analyses, peak lists must be aligned to each other and sets of related peaks must be grouped based on common chemical shift dimensions. Even when programs can perform peak grouping, they require the user to provide uniform match tolerances or use default values. However, peak grouping is further complicated by multiple sources of variance in peak position limiting the effectiveness of grouping methods that utilize uniform match tolerances. In addition, no method currently exists for deriving peak positional variances from single peak lists for grouping peaks into spin systems, i.e. spin system grouping within a single peak list. Therefore, we developed a complementary pair of peak list registration analysis and spin system grouping algorithms designed to overcome these limitations. We have implemented these algorithms into an approach that can identify multiple dimension-specific positional variances that exist in a single peak list and group peaks from a single peak list into spin systems. The resulting software tools generate a variety of useful statistics on both a single peak list and pairwise peak list alignment, especially for quality assessment of peak list datasets. We used a range of low and high quality experimental solution NMR and solid-state NMR peak lists to assess performance of our registration analysis and grouping algorithms. Analyses show that an algorithm using a single iteration and uniform match tolerances approach is only able to recover from 50 to 80% of the spin systems due to the presence of multiple sources of variance. Our algorithm recovers additional spin systems by reevaluating match tolerances in multiple iterations. To facilitate evaluation of the algorithms, we developed a peak list simulator within our nmrstarlib package that generates user-defined assigned peak lists from a given BMRB entry or database of entries. In addition, over 100,000 simulated peak lists with one or two sources of variance were generated to evaluate the performance and robustness of these new registration analysis and peak grouping algorithms.
NASA Technical Reports Server (NTRS)
Lambert, Winifred C.; Merceret, Francis J. (Technical Monitor)
2002-01-01
This report describes the results of the ANU's (Applied Meteorology Unit) Short-Range Statistical Forecasting task for peak winds. The peak wind speeds are an important forecast element for the Space Shuttle and Expendable Launch Vehicle programs. The Keith Weather Squadron and the Spaceflight Meteorology Group indicate that peak winds are challenging to forecast. The Applied Meteorology Unit was tasked to develop tools that aid in short-range forecasts of peak winds at tower sites of operational interest. A 7 year record of wind tower data was used in the analysis. Hourly and directional climatologies by tower and month were developed to determine the seasonal behavior of the average and peak winds. In all climatologies, the average and peak wind speeds were highly variable in time. This indicated that the development of a peak wind forecasting tool would be difficult. Probability density functions (PDF) of peak wind speed were calculated to determine the distribution of peak speed with average speed. These provide forecasters with a means of determining the probability of meeting or exceeding a certain peak wind given an observed or forecast average speed. The climatologies and PDFs provide tools with which to make peak wind forecasts that are critical to safe operations.
NASA Technical Reports Server (NTRS)
Lambert, Winifred C.
2003-01-01
This report describes the results from Phase II of the AMU's Short-Range Statistical Forecasting task for peak winds at the Shuttle Landing Facility (SLF). The peak wind speeds are an important forecast element for the Space Shuttle and Expendable Launch Vehicle programs. The 45th Weather Squadron and the Spaceflight Meteorology Group indicate that peak winds are challenging to forecast. The Applied Meteorology Unit was tasked to develop tools that aid in short-range forecasts of peak winds at tower sites of operational interest. A seven year record of wind tower data was used in the analysis. Hourly and directional climatologies by tower and month were developed to determine the seasonal behavior of the average and peak winds. Probability density functions (PDF) of peak wind speed were calculated to determine the distribution of peak speed with average speed. These provide forecasters with a means of determining the probability of meeting or exceeding a certain peak wind given an observed or forecast average speed. A PC-based Graphical User Interface (GUI) tool was created to display the data quickly.
[Atmospheric correction of visible-infrared band FY-3A/MERSI data based on 6S model].
Wu, Yong-Li; Luan, Qing; Tian, Guo-Zhen
2011-06-01
Based on the observation data from the meteorological stations in Taiyuan City and its surrounding areas of Shanxi Province, the atmosphere parameters for 6S model were supplied, and the atmospheric correction of visible-infrared band (precision 250 meters) FY-3A/MERSI data was conducted. After atmospheric correction, the range of visible-infrared band FY-3A/MERSI data was widened, reflectivity increased, high peak was higher, and distribution histogram was smoother. In the meantime, the threshold value of NDVI data reflecting vegetation condition increased, and its high peak was higher, more close to the real data. Moreover, the color synthesis image of correction data showed more abundant information, its brightness increased, contrast enhanced, and the information reflected was more close to real.
Chatterji, Tapan; Jalarvo, Niina
2013-04-17
We have investigated the low energy excitations in metallic Ho by high resolution neutron spectroscopy. We found at T = 3 K clear inelastic peaks in the energy loss and energy gain sides, along with the central elastic peak. The energy of this low energy excitation, which is 26.59 ± 0.02 μeV at T = 3 K, decreased continuously and became zero at TN ≈ 130 K. By fitting the data in the temperature range 100-127.5 K with a power law we obtained the power-law exponent β = 0.37 ± 0.02, which agrees with the expected value β = 0.367 for a three-dimensional Heisenberg model. Thus the energy of the low energy excitations can be associated with the order parameter.
Waltemeyer, S.D.
1994-01-01
Traveltime characteristics were determined using stream-velocity data and tracer-dye data for a reach of the Rio Grande. Traveltimes determined by the stream-velocity method were virtually the same as those determined by the tracer-dye and tracer-gas technique. The mean velocity of the stream was 1.12 miles per hour at a flow of about 300 cubic feet per second. Reaeration characteristics were determined using a propane tracer gas and a tracer-dye (rhodamine WT). Reaeration coefficients were adjusted for water temperature and the effects of wind movement on the water surface. The peak method-adjusted reaeration-coefficient mean value for the reach was 7.0 per day and ranged from 4.6 to 8.3 per day. The area method-adjusted reaeration- coefficient mean value for the reach was 7.7 per day and ranged from 5.5 to 10.4 per day.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shirakashi, Ryo, E-mail: aa21150@iis.u-tokyo.ac.jp; Mischke, Miriam; Fischer, Peter
2012-11-09
Highlights: Black-Right-Pointing-Pointer Electrorotation offers a non-invasive tool for dielectric analysis of fish embryos. Black-Right-Pointing-Pointer The three-shell dielectric model matches the rotation spectra of medaka eggs. Black-Right-Pointing-Pointer The capacitance value suggests a double-membrane structure of yolk envelope. -- Abstract: The Japanese medaka fish, Oryzias latipes, has become a powerful vertebrate model organism in developmental biology and genetics. The present study explores the dielectric properties of medaka embryos during pre-hatching development by means of the electrorotation (ROT) technique. Due to their layered structure, medaka eggs exhibited up to three ROT peaks in the kHz-MHz frequency range. During development from blastula to earlymore » somite stage, ROT spectra varied only slightly. But as the embryo progressed to the late-somite stage, the ROT peaks underwent significant changes in frequency and amplitude. Using morphological data obtained by light and electron microscopy, we analyzed the ROT spectra with a three-shell dielectric model that accounted for the major embryonic compartments. The analysis yielded a very high value for the ionic conductivity of the egg shell (chorion), which was confirmed by independent osmotic experiments. A relatively low capacitance of the yolk envelope was consistent with its double-membrane structure revealed by transmission electron microscopy. Yolk-free dead eggs exhibited only one co-field ROT peak, shifted markedly to lower frequencies with respect to the corresponding peak of live embryos. The dielectric data may be useful for monitoring the development and changes in fish embryos' viability/conditions in basic research and industrial aquaculture.« less
Cardiorespiratory fitness of a Brazilian regional sample distributed in different tables.
Belli, Karlyse Claudino; Callegaro, Carine C; Calegaro, Carine; Richter, Cleusa Maria; Klafke, Jonatas Zeni; Stein, Ricardo; Viecili, Paulo Ricardo Nazario
2012-09-01
Most classification tables of cardiorespiratory fitness (CRF) used in clinical practice are international and have not been validated for the Brazilian population. That can result in important discrepancies when that classification is extrapolated to our population. To assess the use of major CRF tables available in a Brazilian population sample of the Central High Plan of the state of Rio Grande do Sul (RS). This study assessed the retrospective data of 2,930 individuals, living in 36 cities of the Central High Plan of the state of RS, and considered the following: presence of risk factors for cardiovascular disease and estimated maximum oxygen consumption (VO2peak) values obtained through exercise test with Bruce protocol. To classify CRF, the individuals were distributed according to sex, inserted in their respective age groups in the Cooper, American Heart Association (AHA) and Universidade Federal de São Paulo (Unifesp) tables, and classified according to their VO2peak. Women had lower VO2peak values as compared with those of men (23.5 ± 8.5 vs. 31.7 ± 10.8 mL.kg-1.min-1, p < 0.001). Considering both sexes, VO2peak showed an inverse and moderate correlation with age (R = -0.48, p < 0.001). An important discrepancy in the CRF classification levels was observed between the tables, ranging from 49% (Cooper x AHA) to 75% (Unifesp x AHA). Our findings indicate important discrepancy in the CRF classification levels of the tables assessed. Future studies could assess whether international tables could be used for the Brazilian population and populations of different regions of Brazil.
Empirical Characterization of Low-Altitude Ion Flux Derived from TWINS
NASA Astrophysics Data System (ADS)
Goldstein, J.; LLera, K.; McComas, D. J.; Redfern, J.; Valek, P. W.
2018-05-01
In this study we analyze ion differential flux from 10 events between 2008 and 2015. The ion fluxes are derived from low-altitude emissions (LAEs) in energetic neutral atom (ENA) images obtained by Two Wide-angle Imaging Neutral-atom Spectrometers (TWINS). The data set comprises 119.44 hr of observations, including 4,284 per energy images with 128,277 values of differential ENA flux from pixels near Earth's limb. Limb pixel data are extracted and mapped to a common polar ionospheric grid and associated with values of the Dst index. Statistical analysis is restricted to pixels within 10% of the LAE emissivity peak. For weak Dst conditions we find a premidnight peak in the average ion precipitation, whose flux and location are relatively insensitive to energy. For moderate Dst, elevated flux levels appear over a wider magnetic local time (MLT) range, with a separation of peak locations by energy. Strong disturbances bring a dramatic flux increase across the entire nightside at all energies but strongest for low energies in the postmidnight sector. The arrival of low-energy ions can lower the average energy for strong Dst, even as it raises the total integral number flux. TWINS-derived ion fluxes provide a macroscale measurement of the average precipitating ion distribution and confirm that convection, either quasi-steady or bursty, is an important process controlling the spatial and spectral properties of precipitating ions. The premidnight peak (weak Dst), MLT widening and energy-versus-MLT dependence (moderate Dst), and postmidnight low-energy ion enhancement (strong Dst) are consistent with observations and models of steady or bursty convective transport.
Age-related apparent diffusion coefficient changes in the normal brain.
Watanabe, Memi; Sakai, Osamu; Ozonoff, Al; Kussman, Steven; Jara, Hernán
2013-02-01
To measure the mean diffusional age-related changes of the brain over the full human life span by using diffusion-weighted spin-echo single-shot echo-planar magnetic resonance (MR) imaging and sequential whole-brain apparent diffusion coefficient (ADC) histogram analysis and, secondarily, to build mathematical models of these normal age-related changes throughout human life. After obtaining institutional review board approval, a HIPAA-compliant retrospective search was conducted for brain MR imaging studies performed in 2007 for various clinical indications. Informed consent was waived. The brain data of 414 healthy subjects (189 males and 225 females; mean age, 33.7 years; age range, 2 days to 89.3 years) were obtained with diffusion-weighted spin-echo single-shot echo-planar MR imaging. ADC histograms of the whole brain were generated. ADC peak values, histogram widths, and intracranial volumes were plotted against age, and model parameters were estimated by using nonlinear regression. Four different stages were identified for aging changes in ADC peak values, as characterized by specific mathematical terms: There were age-associated exponential decays for the maturation period and the development period, a constant term for adulthood, and a linear increase for the senescence period. The age dependency of ADC peak value was simulated by using four-term six-coefficient function, including biexponential and linear terms. This model fit the data very closely (R(2) = 0.91). Brain diffusivity as a whole demonstrated age-related changes through four distinct periods of life. These results could contribute to establishing an ADC baseline of the normal brain, covering the full human life span.
Cheng, Rongzhu; Feng, Qi; Ortwerth, Beryl J
2006-05-01
We previously reported chromatographic evidence supporting the similarity of yellow chromophores isolated from aged human lens proteins, early brunescent cataract lens proteins and calf lens proteins ascorbylated in vitro [Cheng, R. et al. Biochimica et Biophysica Acta 1537, 14-26, 2001]. In this paper, new evidence supporting the chemical identity of the modified amino acids in these protein populations were collected by using a newly developed two-dimensional LC-MS mapping technique supported by tandem mass analysis of the major species. The pooled water-insoluble proteins from aged normal human lenses, early stage brunescent cataract lenses and calf lens proteins reacted with or without 20 mM ascorbic acid in air for 4 weeks were digested with a battery of proteolytic enzymes under argon to release the modified amino acids. Aliquots equivalent to 2.0 g of digested protein were subjected to size-exclusion chromatography on a Bio-Gel P-2 column and four major A330nm-absorbing peaks were collected. Peaks 1, 2 and 3, which contained most of the modified amino acids were concentrated and subjected to RP-HPLC/ESI-MS, and the mass elution maps were determined. The samples were again analyzed and those peaks with a 10(4) - 10(6) response factor were subjected to MS/MS analysis to identify the daughter ions of each modification. Mass spectrometric maps of peaks 1, 2 and 3 from cataract lenses showed 58, 40 and 55 mass values, respectively, ranging from 150 to 600 Da. Similar analyses of the peaks from digests of the ascorbylated calf lens proteins gave 81, 70 and 67 mass values, respectively, of which 100 were identical to the peaks in the cataract lens proteins. A total of 40 of the major species from each digest were analyzed by LC-MS/MS and 36 were shown to be identical. Calf lens proteins incubated without ascorbic acid showed several similar mass values, but the response factors were 100 to 1000-fold less for every modification. Based upon these data, we conclude that the majority of the major modified amino acids present in early stage brunescent Indian cataract lens proteins appear to arise as a result of ascorbic acid modification, and are presumably advanced glycation end-products.
Bongers, Bart C; Rijks, Ester B G; Harsevoort, Arjan G J; Takken, Tim; van Brussel, Marco
2016-05-01
Physical fitness levels in youth with osteogenesis imperfecta (OI) who use wheelchairs are unknown. The 10-m Shuttle Ride Test (SRiT) has recently been introduced as a field test to determine cardiorespiratory fitness in children with cerebral palsy who self-propel a wheelchair. The purpose of this study was to investigate the feasibility and reproducibility of the SRiT, as well as the physiological responses to the SRiT, in youth with moderate-to-severe OI between 8 and 25 years of age who self-propel a wheelchair at least for long distances. A test-retest design was used. Thirteen patients with OI (8 boys, 5 girls; mean±SD values for age=15.5±6.4 years) using a manual wheelchair performed 2 SRiTs within 2 weeks. Adverse events, reached stage, peak heart rate (HRpeak), peak respiratory exchange ratio (RERpeak), peak oxygen uptake (V̇o2peak), and peak minute ventilation (V̇epeak) were the main outcome parameters. All participants performed a maximal effort at both SRiTs (mean±SD values for HRpeak of 195±9 beats per minute [bpm], RERpeak of 1.32±0.16, V̇o2peak of 25.4±5.6 mL·kg(-1)·min(-1), and V̇epeak of 47.9±18.6 L·min(-1)), without adverse events. The intraclass correlation coefficient of the reached stage showed excellent reliability (.95). Limits of agreement (LoA) analysis revealed acceptable LoA for reached stage (mean bias=-0.58, range=-2.50 to +1.35). There was a low correlation between reached stage and V̇o2peak (r=.61 and r=.45 for the first and second SRiTs, respectively). The influence of wheelchair properties and individually adjusted wheelchair designs was not examined. The SRiT appears to be a feasible, safe, and reproducible maximal field test in youth with OI using wheelchairs at least for long distances. This field test might be useful to provide an indication of physical fitness and to assess the efficacy of interventions on physical fitness in these patients. © 2016 American Physical Therapy Association.
Fingerprinting malathion vapor: a simulant for VX nerve agent
NASA Astrophysics Data System (ADS)
Song, Renbo; Ding, Yujie J.; Zotova, Ioulia B.
2008-04-01
Being motivated by the possibility of fingerprinting and detecting VX nerve agent, we have investigated its stimulant, i.e. malathion vapor, which is less toxic and commercially available, in the far-infrared/THz transition region and THz frequency range. Such a spectroscopic study was carried out by using Fourier transform infrared spectroscopy (FTIR). Our intention is to obtain a specific spectroscopic signature of VX nerve agent as a chemical warfare agent. Following our experimental result, we have successfully observed eleven new absorption peaks from malathion vapor in the spectral ranges from 15 cm -1 to 68 cm -1 and from 75 cm -1 to 640 cm -1. Specifically, in the far-infrared/THz transition region, we have observed eight peaks and whereas in the THz region we have identified three relatively weak transition peaks. In addition, we have investigated the dependence of the absorption spectra on temperature in the range from room temperature to 60°C. In both of the frequency ranges, we have found that absorption coefficients significantly increase with increasing temperature. By comparing the transition peaks in the two frequency ranges, we have concluded that the frequency range of 400-640cm -1 is an optimal range for fingerprinting this chemical specie. We have designated two peaks for effectively and accurately identifying the VX nerve agents and one peak for differentiating between malathion and VX nerve agent.
Underwood, M.B.; Shelton, K.L.; McLaughlin, R.J.; Laughland, M.M.; Solomon, R.M.
1999-01-01
This study documents three localities in the Franciscan accretionary complex of northern California, now adjacent to the San Andreas fault, that were overprinted thermally between 13.9 and 12.2 Ma: Point Delgada-Shelter Cove (King Range terrane); Bolinas Ridge (San Bruno Mountain terrane); and Mount San Bruno (San Bruno Mountain terrane). Vein assemblages of quartz, carbonate, sulfide minerals, and adularia were precipitated locally in highly fractured wall rock. Vitrinite reflectance (Rm) values and illite crystallinity decrease away from the zones of metalliferous veins, where peak wall-rock temperatures, as determined from Rm, were as high as 315??C. The ??18O values of quartz and calcite indicate that two separate types of fluid contributed to vein precipitation. Higher ??18O fluids produced widespread quartz and calcite veins that are typical of the regional paleothermal regime. The widespread veins are by-products of heat conduction and diffuse fluid flow during zeolite and prehnite-pumpellyite-grade metamorphism, and we interpret their paleofluids to have evolved through dehydration reactions and/or extensive isotopic exchange with accreted Franciscan rocks. Lower ??18O fluids, in contrast, evolved from relatively high temperature exchange between seawater (or meteoric water) and basaltic and/or sedimentary host rocks; focused flow of those fluids resulted in local deposition of the metalliferous veins. Heat sources for the three paleothermal anomalies remain uncertain and may have been unrelated to one another. Higher temperature metalliferous fluids in the King Range terrane could have advected either from a site of ridge-trench interaction north of the Mendocino fracture zone or from a "slabless window" in the wake of the northward migrating Mendocino triple junction. A separate paradox involves the amount of Quaternary offset of Franciscan basement rocks near Shelter Cove by on-land faults that some regard as the main active trace of the San Andreas plate boundary. Contouring of vitrinite reflectance values to the north of an area affected by A.D. 1906 surface rupture indicates that the maximum dextral offset within the interior of the King Range terrane is only 2.5 km. If this fault extends inland, and if it has been accommodating most of the strike-slip component of San Andreas offset at a rate of 3-4 cm/yr, then its activity began only 83-62 ka. This interpretation would also mean that a longer term trace of the San Andreas fault must be nearby, either offshore or along the northeast boundary of the King Range terrane. An offshore fault trace would be consistent with peak heating of King Range strata north of the Mendocino triple junction. Conversely, shifting the fault to the east would be compatible with a slabless window heat source and long-distance northward translation of the King Range terrane after peak heating.
NASA Technical Reports Server (NTRS)
Vallejo, J.J.; Hejduk, M.D.; Stamey, J. D.
2015-01-01
Satellite conjunction risk typically evaluated through the probability of collision (Pc). Considers both conjunction geometry and uncertainties in both state estimates. Conjunction events initially discovered through Joint Space Operations Center (JSpOC) screenings, usually seven days before Time of Closest Approach (TCA). However, JSpOC continues to track objects and issue conjunction updates. Changes in state estimate and reduced propagation time cause Pc to change as event develops. These changes a combination of potentially predictable development and unpredictable changes in state estimate covariance. Operationally useful datum: the peak Pc. If it can reasonably be inferred that the peak Pc value has passed, then risk assessment can be conducted against this peak value. If this value is below remediation level, then event intensity can be relaxed. Can the peak Pc location be reasonably predicted?
REVERSING CYCLIC ELASTO-PLASTIC DEMANDS ON STRUCTURES DURING STRONG MOTION EARTHQUAKE EXCITATION.
Perez, V.; Brady, A.G.; Safak, E.
1986-01-01
Using the horizontal components from El Centro 1940, Taft 1952, and 4 accelerograms from the San Fernando earthquake of 2/9/71, the time history of the elasto-plastic displacement response was calculated for oscillators having periods within the range of 1 to 6 s and ductility factors within the range of 3 to 6. The Nth largest peak of the elasto-plastic response (N equals 2,4,8,16), when expressed as a percentage of maximum response (that is, N equals 1), is fairly independent of period within our period range. When considering only plastic peaks occurring, sometimes in a one-directional group of peaks, in the reverse direction from the preceding plastic peak, the amplitude of the Nth reversing plastic peak is similar to the Nth elastic peak, regardless of the ductility factor.
Variability in δ13C values between individual Daphnia ephippia: Implications for palaeo-studies
NASA Astrophysics Data System (ADS)
Schilder, Jos; van Roij, Linda; Reichart, Gert-Jan; Sluijs, Appy; Heiri, Oliver
2018-06-01
The stable carbon isotope ratio (δ13C value) of Daphnia spp. resting egg shells (ephippia) provides information on past changes in Daphnia diet. Measurements are typically performed on samples of ≥20 ephippia, which obscures the range of values associated with individual ephippia. Using a recently developed laser ablation-based technique, we perform multiple δ13C analyses on individual ephippia, which show a high degree of reproducibility (standard deviations 0.1-0.5‰). We further measured δ13C values of 13 ephippia from surface sediments of three Swiss lakes. In the well-oxygenated lake with low methane concentrations, δ13C values are close to values typical for algae (-31.4‰) and the range in values is relatively small (5.8‰). This variability is likely driven by seasonal (or inter-annual) variability in algae δ13C values. In two seasonally anoxic lakes with higher methane concentrations, average values were lower (-41.4 and -43.9‰, respectively) and the ranges much larger (10.7 and 20.0‰). We attribute this variability to seasonal variation in incorporation of methane-derived carbon. In one lake we identify two statistically distinct isotopic populations, which may reflect separate production peaks. The potentially large within-sample variability should be considered when interpreting small-amplitude, short-lived isotope excursions based on samples consisting of few ephippia. We show that measurements on single ephippia can be performed using laser ablation, which allows for refined assessments of past Daphnia diet and carbon cycling in lake food webs. Furthermore, our study provides a basis for similar measurements on other chitinous remains (e.g. from chironomids, bryozoans).
Malek, Mahrooz; Pourashraf, Maryam; Gilani, Mitra Modares; Gity, Masoumeh
2015-01-01
The aim of this study was to assess the role of the presence of a choline peak in 3 Tesla 1H magnetic resonance spectroscopy (MRS) for differentiating benign from malignant adnexal masses. A total of 46 adnexal masses (23 malignant and 23 benign) underwent 1H MRS study prior to surgery to assess the presence of choline peak. A choline peak was detected in 16 malignant masses (69.5%) and was absent in the other 7 (30.5%). A choline peak was only detected in 6 (26%) of the benign adnexal masses. The presence of an MRS choline peak had a sensitivity of 69.5%, a specificity of 74%, a positive predictive value (PPV) of 72.7%, and a negative predictive value (NPV) of 71% for diagnosing malignant adnexal masses. A significant difference between the frequency of mean choline peaks in benign and malignant adnexal masses was observed (P value<0.01). A 1H MRS choline peak is seen in malignant adnexal masses more frequently than the benign masses, and may be helpful for diagnosing malignant adnexal masses.
NASA Technical Reports Server (NTRS)
Degnan, J. J., III; Zagwodski, T. W.
1979-01-01
A prototype Q-switched Nd:YAG laser transmitter intended for use in the NASA mobile laser ranging system was subjected to various tests of temporal pulse shape and stability, output energy and stability, beam divergence, and range bias errors. Peak to peak variations in the mean range were as large as 30 cm and drift rates of system bias with time as large as 6 mm per minute of operation were observed. The incorporation of a fast electro-optic cavity dump into the oscillator gave significantly improved results. Reevaluation of the ranging performance after modification showed a reduction in the peak to peak variation in the mean range to the 2 or 3 cm level and a drift rate of system time biases of less than 1 mm per minute of operation. A qualitative physical explanation for the superior performance of cavity dumped lasers is given.
Koltun, G.F.
2009-01-01
This report describes the results of a study to determine frequency characteristics of postregulation annual peak flows at streamflow-gaging stations at or near the Lockington, Taylorsville, Englewood, Huffman, and Germantown dry dams in the Miami Conservancy District flood-protection system (southwestern Ohio) and five other streamflow-gaging stations in the Great Miami River Basin further downstream from one or more of the dams. In addition, this report describes frequency characteristics of annual peak elevations of the dry-dam pools. In most cases, log-Pearson Type III distributions were fit to postregulation annual peak-flow values through 2007 (the most recent year of published peak-flow values at the time of this analysis) and annual peak dam-pool storage values for the period 1922-2008 to determine peaks with recurrence intervals of 2, 5, 10, 25, 50, 100, 200, and 500 years. For one streamflow-gaging station (03272100) with a short period of record, frequency characteristics were estimated by means of a process involving interpolation of peak-flow yields determined for an upstream and downstream gage. Once storages had been estimated for the various recurrence intervals, corresponding dam-pool elevations were determined from elevation-storage ratings provided by the Miami Conservancy District.
ZT Optimization: An Application Focus
Tuley, Richard; Simpson, Kevin
2017-01-01
Significant research has been performed on the challenge of improving thermoelectric materials, with maximum peak figure of merit, ZT, the most common target. We use an approximate thermoelectric material model, matched to real materials, to demonstrate that when an application is known, average ZT is a significantly better optimization target. We quantify this difference with some examples, with one scenario showing that changing the doping to increase peak ZT by 19% can lead to a performance drop of 16%. The importance of average ZT means that the temperature at which the ZT peak occurs should be given similar weight to the value of the peak. An ideal material for an application operates across the maximum peak ZT, otherwise maximum performance occurs when the peak value is reduced in order to improve the peak position. PMID:28772668
Peak skin and eye lens radiation dose from brain perfusion CT based on Monte Carlo simulation.
Zhang, Di; Cagnon, Chris H; Villablanca, J Pablo; McCollough, Cynthia H; Cody, Dianna D; Stevens, Donna M; Zankl, Maria; Demarco, John J; Turner, Adam C; Khatonabadi, Maryam; McNitt-Gray, Michael F
2012-02-01
The purpose of our study was to accurately estimate the radiation dose to skin and the eye lens from clinical CT brain perfusion studies, investigate how well scanner output (expressed as volume CT dose index [CTDI(vol)]) matches these estimated doses, and investigate the efficacy of eye lens dose reduction techniques. Peak skin dose and eye lens dose were estimated using Monte Carlo simulation methods on a voxelized patient model and 64-MDCT scanners from four major manufacturers. A range of clinical protocols was evaluated. CTDI(vol) for each scanner was obtained from the scanner console. Dose reduction to the eye lens was evaluated for various gantry tilt angles as well as scan locations. Peak skin dose and eye lens dose ranged from 81 mGy to 348 mGy, depending on the scanner and protocol used. Peak skin dose and eye lens dose were observed to be 66-79% and 59-63%, respectively, of the CTDI(vol) values reported by the scanners. The eye lens dose was significantly reduced when the eye lenses were not directly irradiated. CTDI(vol) should not be interpreted as patient dose; this study has shown it to overestimate dose to the skin or eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice. These actions should be considered when they are consistent with the clinical task and patient anatomy.
Gross, T.S.; Wieser, C.M.; Sepulveda, M.S.; Wiebe, J.J.; Schoeb, T.R.; Denslow, N.D.
2002-01-01
The annual reproductive cycle of hatchery-raised largemouth bass (Florida subspecies Micropterus salmoides floridanus) was characterized over a one-year period. Largemouth bass have a distinct annual reproductive cycle with a spring spawning season (approximately between mid-January and mid-June). Cycle characterization focused on an evaluation of gonadal development and plasma concentrations of several sex steroids and vitellogenin (VTG). Adult largemouth bass (n = 20: 10 females and 10 males) were collected monthly from hatchery ponds for one full calendar year. Plasma samples were analyzed for estradiol-17?? (E2), 11-ketotestosterone (11-KT), testosterone (T), progesterone (P), and VTG. Gonadal tissues were weighed to calculate gonadosomatic index (GSI) and evaluated histologically to characterize reproductive stage. In both sexes, GSI began to increase in November, and peaked in February-March. Increases in gonad weights were correlated with maturation of gonads as evidenced by histological evaluations. Bass exhibited seasonal changes in plasma sex steroids and VTG. In males, 11-KT was the only sex steroid that showed strong seasonality, with highest values in February. In females, although E2 and T concentrations followed a similar annual cycle, with highest and lowest values in February and August, respectively, the strongest pattern was observed with E2. 11-KT concentrations were less variable across months, and values were about half of those observed in males. In females, P peaked two months after E2, with high values still in May and June and decreased thereafter, and VTG began to increase in October, but peaked a month prior to the observed peaked in E2. VTG was also detected in males but at concentrations that were about 1/12 that of females, and no seasonal pattern was evident. This study is the first to fully characterize the seasonal endocrine cycle for largemouth bass. These data will be useful when conducting reproductive evaluations of free-ranging populations of largemouth bass and for assessing potential reproductive effects due to environmental contaminants in this species. ?? 2002 by the American Fisheries Society.
Ismail, Catheeja; Zabal, Johannah; Hernandez, Haniel J.; Woletz, Paula; Manning, Heather; Teixeira, Carla; DiPietro, Loretta; Blackman, Marc R.; Harris-Love, Michael O.
2015-01-01
Introduction: Age-related changes in muscle mass and muscle tissue composition contribute to diminished strength in older adults. The objectives of this study are to examine if an assessment method using mobile diagnostic ultrasound augments well-known determinants of lean body mass (LBM) to aid sarcopenia staging, and if a sonographic measure of muscle quality is associated with muscle performance. Methods: Twenty community-dwelling female subjects participated in the study (age = 43.4 ± 20.9 years; BMI: 23.8, interquartile range: 8.5). Dual energy X-ray absorptiometry (DXA) and diagnostic ultrasound morphometry were used to estimate LBM. Muscle tissue quality was estimated via the echogenicity using grayscale histogram analysis. Peak force was measured with grip dynamometry and scaled for body size. Bivariate and multiple regression analyses were used to determine the association of the predictor variables with appendicular lean mass (aLM/ht2), and examine the relationship between scaled peak force values and muscle echogenicity. The sarcopenia LBM cut point value of 6.75 kg/m2 determined participant assignment into the Normal LBM and Low LBM subgroups. Results: The selected LBM predictor variables were body mass index (BMI), ultrasound morphometry, and age. Although BMI exhibited a significant positive relationship with aLM/ht2 (adj. R2 = 0.61, p < 0.001), the strength of association improved with the addition of ultrasound morphometry and age as predictor variables (adj. R2 = 0.85, p < 0.001). Scaled peak force was associated with age and echogenicity (adj. R2 = 0.53, p < 0.001), but not LBM. The Low LBM subgroup of women (n = 10) had higher scaled peak force, lower BMI, and lower echogenicity values in comparison to the Normal LBM subgroup (n = 10; p < 0.05). Conclusions: Diagnostic ultrasound morphometry values are associated with LBM, and improve the BMI predictive model for aLM/ht2 in women. In addition, ultrasound proxy measures of muscle quality are more strongly associated with strength than muscle mass within the study sample. PMID:26578974
Ismail, Catheeja; Zabal, Johannah; Hernandez, Haniel J; Woletz, Paula; Manning, Heather; Teixeira, Carla; DiPietro, Loretta; Blackman, Marc R; Harris-Love, Michael O
2015-01-01
Age-related changes in muscle mass and muscle tissue composition contribute to diminished strength in older adults. The objectives of this study are to examine if an assessment method using mobile diagnostic ultrasound augments well-known determinants of lean body mass (LBM) to aid sarcopenia staging, and if a sonographic measure of muscle quality is associated with muscle performance. Twenty community-dwelling female subjects participated in the study (age = 43.4 ± 20.9 years; BMI: 23.8, interquartile range: 8.5). Dual energy X-ray absorptiometry (DXA) and diagnostic ultrasound morphometry were used to estimate LBM. Muscle tissue quality was estimated via the echogenicity using grayscale histogram analysis. Peak force was measured with grip dynamometry and scaled for body size. Bivariate and multiple regression analyses were used to determine the association of the predictor variables with appendicular lean mass (aLM/ht(2)), and examine the relationship between scaled peak force values and muscle echogenicity. The sarcopenia LBM cut point value of 6.75 kg/m(2) determined participant assignment into the Normal LBM and Low LBM subgroups. The selected LBM predictor variables were body mass index (BMI), ultrasound morphometry, and age. Although BMI exhibited a significant positive relationship with aLM/ht(2) (adj. R (2) = 0.61, p < 0.001), the strength of association improved with the addition of ultrasound morphometry and age as predictor variables (adj. R (2) = 0.85, p < 0.001). Scaled peak force was associated with age and echogenicity (adj. R (2) = 0.53, p < 0.001), but not LBM. The Low LBM subgroup of women (n = 10) had higher scaled peak force, lower BMI, and lower echogenicity values in comparison to the Normal LBM subgroup (n = 10; p < 0.05). Diagnostic ultrasound morphometry values are associated with LBM, and improve the BMI predictive model for aLM/ht(2) in women. In addition, ultrasound proxy measures of muscle quality are more strongly associated with strength than muscle mass within the study sample.
Square Wave Voltammetric Determination of Diclofenac in Pharmaceutical Preparations and Human Serum
Ciltas, Ulvihan; Yilmaz, Bilal; Kaban, Selcuk; Akcay, Bilge Kaan; Nazik, Gulsah
2015-01-01
In this study, a simple and reliable square wave voltammetric (SWV) method was developed and validated for determination of diclofenac in pharmaceutical preparations and human serum. The proposed method was based on electrooxidation of diclofenac at platinum electrode in 0.1 M TBAClO4/acetonitrile solution. The well-defined two oxidation peaks were observed at 0.87 and 1.27 V, respectively. Calibration curves that were obtained by using current values measured for second peak were linear over the concentration range of 1.5-17.5 μg mL-1 and 2-20 μg mL-1 in supporting electrolyte and serum, respectively. Precision and accuracy were also checked in all media. Intra- and inter-day precision values for diclofenac were less than 3.64, and accuracy (relative error) was better than 2.49%. Developed method in this study is accurate, precise and can be easily applied to Diclomec, Dicloflam and Voltaren tablets as pharmaceutical preparation. Also, the proposed technique was successfully applied to spiked human serum samples. No electroactive interferences from the endogenous substances were found in human serum. PMID:26330859
Square Wave Voltammetric Determination of Diclofenac in Pharmaceutical Preparations and Human Serum.
Ciltas, Ulvihan; Yilmaz, Bilal; Kaban, Selcuk; Akcay, Bilge Kaan; Nazik, Gulsah
2015-01-01
In this study, a simple and reliable square wave voltammetric (SWV) method was developed and validated for determination of diclofenac in pharmaceutical preparations and human serum. The proposed method was based on electrooxidation of diclofenac at platinum electrode in 0.1 M TBAClO4/acetonitrile solution. The well-defined two oxidation peaks were observed at 0.87 and 1.27 V, respectively. Calibration curves that were obtained by using current values measured for second peak were linear over the concentration range of 1.5-17.5 μg mL(-1) and 2-20 μg mL(-1) in supporting electrolyte and serum, respectively. Precision and accuracy were also checked in all media. Intra- and inter-day precision values for diclofenac were less than 3.64, and accuracy (relative error) was better than 2.49%. Developed method in this study is accurate, precise and can be easily applied to Diclomec, Dicloflam and Voltaren tablets as pharmaceutical preparation. Also, the proposed technique was successfully applied to spiked human serum samples. No electroactive interferences from the endogenous substances were found in human serum.
The endogenous dynamics of financial markets: Interaction and information dissemination
NASA Astrophysics Data System (ADS)
Yang, ChunXia; Hu, Sen; Xia, BingYing
2012-06-01
We investigate the process that different interactions between investors will prompt information to propagate along a differentiated path and construct a financial market model. As information spreads, increasingly investors are attracted to participate in trading, then the “herding effect” is magnified gradually, which will induce the topology of market network to change and the price to fluctuate. Especially, under different initial conditions or parameters, the peak and fat-tail property is produced and the obtained statistic values coincide with empirical results: the power-law exponents between the peak value of return probability distribution and the time scales range from 0.579 to 0.747, and the exponents between the accumulation distribution and the return on the tail are close to 3. Besides, the extent of volatility clustering in our produced price series is close to that of S&P 500 and locates between NASDAQ and HSI. All the results obtained here indicate that the continuous variation of the “herding effect” resulting from information propagation among interacting investors may be the origin of stylized facts of price fluctuations.
Synthesis of Al-26 in explosive hydrogen burning
NASA Technical Reports Server (NTRS)
Arnould, M.; Norgaard, H.; Thielemann, F.-K.; Hillebrandt, W.
1980-01-01
The possibility of Al-26 synthesis during the explosive processing of hydrogen-rich material in the outer layers of a supernova or in nova envelopes is investigated. It is found that in the peak temperature range of 1-3 x 10 to the 8th deg K and for expansion time scales of the order of 1-1000 s, values of (Al-26)/(Al-27) as high as 0.1-1 can be obtained for values of 0.001-100,000 for the product of the peak density in g/cu cm and the proton mass fraction. Such a level of Al-26 production is considerably higher than that of recent carbon/neon burning nucleosynthesis models, and is sufficient to account for the magnesium anomalies detected in certain inclusions from the Leoville and Allende meteorites. Al abundances resulting from a hydrodynamical calculation performed on the grounds of a 25 solar mass presupernova model are also presented, and the influence of uncertainties in the input physics is discussed; in particular, the rates of the (Mg-25)(p,gamma)(Al-26) and (Al-26)(p,gamma)(Si-27) key reactions are studied.
Graphene films printable on flexible substrates for sensor applications
NASA Astrophysics Data System (ADS)
Banerjee, Indrani; Faris, Tsegie; Stoeva, Zlatka; Harris, Paul G.; Chen, J.; Sharma, Ashwani K.; Ray, Asim K.
2017-03-01
Fifteen-layered graphene films have been successfully deposited onto flexible substrates using a commercial ink consisting of graphene particles dispersed in an acrylic polymer binder. A value of 74.9× {10}5 {{{cm}}}-2 was obtained for the density of defects, primarily located at the flake edges, from the ratio of the D and G Raman peaks located at 1345 {{{cm}}}-1 and 1575 {{{cm}}}-1 respectively. 0.5 {μ }{{m}} thick drop-cast films on interdigitated silver electrodes exhibited Ohmic conduction with a small activation energy of 12 meV over the temperature range from 260 to 330 {{K}}. The photo-thermoelectric effect is believed to be responsible for photoconduction through graphene films under illumination intensity of 10 mW m-2 at 270 {{nm}}, corresponding to the UV absorption peak. The photo-transient decay at the bias of 1 {{V}} involves two relaxation processes when the illumination is switched off and values of 8.9× {10}3 and 4.3× {10}4 {{s}} are found for the relaxation time constant using the Kohlrauch stretched exponential function analysis.
Gomes, Rayane N; Sousa, Camila P; Casciano, Paulo N S; Ribeiro, Francisco Wirley P; Morais, Simone; de Lima-Neto, Pedro; Correia, Adriana N
2018-07-01
The influence of functionalized multi-walled carbon nanotubes (fMWCNT) in the presence of 1-butyl-3-methylimidazolium hexafluorophosphate ([BMIM]PF 6 ) in different ratios was investigated on the acetaminophen (ACOP) electrochemical determination. The electrochemical behavior of the ACOP exhibited a pair of well-defined redox peaks, suggesting that the reversibility of ACOP was significantly improved in comparison to irreversible oxidation peak on bare GCE. The redox process was controlled by adsorption, involves two electrons and the value of apparent rate constant (k s ) was equal to 14.7 s -1 ± 3.6 s -1 . The analytical curves were obtained for concentrations of ACOP ranging from 0.3 to 3.0 μmol L -1 . The values of the detection limit were calculated from SWV and found to be 6.73 × 10 -8 mol L -1 . The proposed electrochemical sensor exhibited good stability and reproducibility and was applied for ACOP determination in tablets (Tylenol® and Tylenol®DC) with satisfactory results. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Yusufzai, Mohd Zaheer Khan; Vashista, M.
2018-04-01
Barkhausen Noise analysis is a popular and preferred technique for micro-structural characterization. The root mean square value and peak value of Barkhausen Noise burst are important parameters to assess the micro-hardness and residual stress. Barkhausen Noise burst can be enveloped using a curve known as Barkhausen Noise profile. Peak position of profile changes with change in micro-structure. In the present work, raw signal of Barkhausen Noise burst was obtained from Ni based sample at various magnetic field intensity to observe the effect of variation in field intensity on Barkhausen Noise burst. Raw signal was opened using MATLAB to further process for microstructure analysis. Barkhausen Noise analysis parameters such as magnetizing frequency, number of burst, high pass and low pass filter frequency were kept constant and magnetizing field was varied in wide range between 200 Oe to 1200 Oe. The processed profiles of Barkhausen Noise burst obtained at various magnetizing field intensity clearly reveals requirement of optimum magnetic field strength for better characterization of micro-structure.
Kim, Jae-Woong; Kwon, Moon-Seok; Yenuga, Sree Sushma; Kwon, Young-Hoooo
2010-06-01
The study purpose was to investigate the effects of target distance on pivot hip, trunk, pelvis, and kicking leg movements in Taekwondo roundhouse kick. Twelve male black-belt holders executed roundhouse kicks for three target distances (Normal, Short, and Long). Linear displacements of the pivot hip and orientation angles of the pelvis, trunk, right thigh, and right shank were obtained through a three-dimensional video motion analysis. Select displacements, distances, peak orientation angles, and angle ranges were compared among the conditions using one-way repeated measure ANOVA (p < 0.05). Several orientation angle variables (posterior tilt range, peak right-tilted position, peak right-rotated position, peak left-rotated position, and left rotation range of the pelvis; peak hyperextended position and peak right-flexed position of the trunk; peak flexed position, flexion range and peak internal-rotated position of the hip) as well as the linear displacements of the pivot hip and the reach significantly changed in response to different target distances. It was concluded that the adjustment to different target distances was mainly accomplished through the pivot hip displacements, hip flexion, and pelvis left rotation. Target distance mainly affected the reach control function of the pelvis and the linear balance function of the trunk.
NASA Technical Reports Server (NTRS)
Idone, V. P.; Orville, R. E.
1985-01-01
The correlation between peak relative light intensity L(R) and stroke peak current I(R) is examined for 39 subsequent return strokes in two triggered lightning flashes. One flash contained 19 strokes and the other 20 strokes for which direct measurements were available of the return stroke peak current at ground. Peak currents ranged from 1.6 to 21 kA. The measurements of peak relative light intensity were obtained from photographic streak recordings using calibrated film and microsecond resolution. Correlations, significant at better than the 0.1 percent level, were found for several functional relationships. Although a relation between L(R) and I(R) is evident in these data, none of the analytical relations considered is clearly favored. The correlation between L(R) and the maximum rate of current rise is also examined, but less correlation than between L(R) and I(R) is found. In addition, the peak relative intensity near ground is evaluated for 22 dart leaders, and a mean ratio of peak dart leader to peak return stroke relative light intensity was found to be 0.1 with a range of 0.02-0.23. Using two different methods, the peak current near ground in these dart leaders is estimated to range from 0.1 to 6 kA.
Kaafarani, Mirna; Schroer, Christian; Takken, Tim
2017-12-01
Hemodynamic responses to exercise are used as markers of diagnosis for cardiac diseases, systolic blood pressure (SBP) especially. However, the reference values for SBP in children at peak exertion level are outdated. This study aimed to establish current reference values for SBP, rate pressure product (RPP), and circulatory power (CircP). Data from children who previously underwent cardiopulmonary exercise testing were categorized as healthy (N = 184; age 12.6 ± 2.9 years), and CoA patients (N = 25; age 13.0 ± 3.2 years). With the Lambda-Mu-Sigma (LMS) method, percentile curves were made for SBP, CircP, and RPP in function of peak work rate (Wpeak). Data of CoA patients were used to validate the reference values. Wpeak was the best predictor of peak SBP during exercise. The prediction equations for SBP, CircP and RPP were: (0.2853 x Wpeak) + 111.46; (10.56 x Wpeak) + 2550.2 and (61.879 x Wpeak) + 19.887, respectively. CoA patients showed significantly increased values for peak SBP (Z-score 1.063 ± 1.347). This study provides reference values for SBP, RPP, and CircP at peak exercise. These values can be used for objective evaluation of participants 6-18 years of age in a Dutch population.
Ramírez-Vélez, Robinson; Palacios-López, Adalberto; Humberto Prieto-Benavides, Daniel; Enrique Correa-Bautista, Jorge; Izquierdo, Mikel; Alonso-Martínez, Alicia; Lobelo, Felipe
2017-01-01
Our aim was to determine the normative reference values of cardiorespiratory fitness (CRF) and to establish the proportion of subjects with low CRF suggestive of future cardio-metabolic risk. A total of 7244 children and adolescents attending public schools in Bogota, Colombia (55.7% girls; age range of 9-17.9 years) participated in this study. We expressed CRF performance as the nearest stage (minute) completed and the estimated peak oxygen consumption (V˙O 2peak ). Smoothed percentile curves were calculated. In addition, we present the prevalence of low CRF after applying a correction factor to account for the impact of Bogota's altitude (2625 m over sea level) on CRF assessment, and we calculated the number of participants who fell below health-related FITNESSGRAM cut-points for low CRF. Shuttles and V˙O 2peak were higher in boys than in girls in all age groups. In boys, there were higher levels of performance with increasing age, with most gains between the ages of 13 and 17. The proportion of subjects with a low CRF, suggestive of future cardio-metabolic risk (health risk FITNESSGRAM category) was 31.5% (28.2% for boys and 34.1% for girls; X 2 P = .001). After applying a 1.11 altitude correction factor, the overall prevalence of low CRF was 11.5% (9.6% for boys and 13.1% for girls; X 2 P = .001). Our results provide sex- and age-specific normative reference standards for the 20 m shuttle-run test and estimated V˙O 2peak values in a large, population-based sample of schoolchildren from a large Latin-American city at high altitude. © 2016 The Authors American Journal of Human Biology Published by Wiley Periodicals, Inc.
Güven, Sertaç; Kesebir, Sermin; Demirer, R Murat; Bilici, Mustafa
2015-06-01
Our aim in this study was to investigate spectral power density (PSD) in first-episode mania and subsequent remission period and to evaluate their difference. Sixty-nine consecutive cases referring to our hospital within the previous 1 year, who were evaluated as bipolar disorder manic episode according to The Diagnostic and Statistical Manual of Mental Disorders-IV (DSM-IV) at the first episode and had the informed consent form signed by first degree relatives, were included in this study. Exclusion criteria included having previous depressive episode, using drugs which could influence electroencephalographic activity before electroencephalography (EEG), and having previous neurological disease, particularly epilepsy, head trauma, and/or loss of consciousness. EEG records were obtained using a digital device in 16 channels; 23 surface electrodes were placed according to the International 10-20 system. Spectral power density (dbμV/Hz) of EEG signal provided information on the power carried out by EEG waves in defined frequancy range per unit frequency in the present study. A peak power value detected on the right with FP2P4 and on the left with F7T3 electrodes were found to be higher in the manic episode than in the remission period (p=0.018 and 0.025). In the remission period, in cases with psychotic symptoms during the manic period, F4C4 peak power value was found to be lower than that in cases with no psychotic findings during the manic period (p=0.027). There was no relation was found between YMRS scores and peak power scores. Electrophysiological corollary of mood episode is present from the onset of the disease, and it differs between the manic and remission periods of bipolar disorder. In the remission period, peak power values of PSD distinguish cases with psychotic findings from cases without psychotic findings when they were manic.
Detailed budget analysis of HONO in central London reveals a missing daytime source
NASA Astrophysics Data System (ADS)
Lee, J. D.; Whalley, L. K.; Heard, D. E.; Stone, D.; Dunmore, R. E.; Hamilton, J. F.; Young, D. E.; Allan, J. D.; Laufs, S.; Kleffmann, J.
2015-08-01
Measurements of HONO were carried out at an urban background site near central London as part of the Clean air for London (ClearfLo) project in summer 2012. Data was collected from 22 July-18 August 2014, with peak values of up to 1.8 ppbV at night and non-zero values of between 0.2 and 0.6 ppbV seen during the day. A wide range of other gas phase, aerosol, radiation and meteorological measurements were made concurrently at the same site, allowing a detailed analysis of the chemistry to be carried out. The peak HONO/NOx ratio of 0.04 is seen at ~ 02:00 UTC, with the presence of a second, daytime peak in HONO/NOx of similar magnitude to the night-time peak suggesting a significant secondary daytime HONO source. A photostationary state calculation of HONO involving formation from the reaction of OH and NO and loss from photolysis, reaction with OH and dry deposition shows a significant underestimation during the day, with calculated values being close to zero, compared to the measurement average of 0.4 ppbV at midday. The addition of further HONO sources, including postulated formation from the reaction of HO2 with NO2 and photolysis of HNO3, increases the daytime modelled HONO to 0.1 ppbV, still leaving a significant extra daytime source. The missing HONO is plotted against a series of parameters including NO2 and OH reactivity, with little correlation seen. Much better correlation is observed with the product of these species with j(NO2), in particular NO2 and the product of NO2 with OH reactivity. This suggests the missing HONO source is in some way related to NO2 and also requires sunlight. The effect of the missing HONO to OH radical production is also investigated and it is shown that the model needs to be constrained to measured HONO in order to accurately reproduce the OH radical measurements.
Liu, Boyang; Dardeer, Ahmed M; Moody, William E; Edwards, Nicola C; Hudsmith, Lucy E; Steeds, Richard P
2018-02-01
Reproducible and repeatable assessment of right heart function is vital for monitoring congenital and acquired heart disease. There is increasing evidence for the additional value of myocardial deformation (strain and strain rate) in determining prognosis. This study aims to determine the reproducibility of deformation analyses in the right heart using cardiovascular magnetic resonance feature tracking (FT-CMR); and to establish normal ranges within an adult population. A cohort of 100 healthy subjects containing 10 males and 10 females from each decade of life between the ages of 20 and 70 without known congenital or acquired cardiovascular disease, hypertension, diabetes, dyslipidaemia or renal, hepatic, haematologic and systemic inflammatory disorders underwent FT-CMR assessment of right ventricular (RV) and right atrial (RA) myocardial strain and strain rate. RV longitudinal strain (Ell) was -21.9±3.24% (FW+S Ell) and -24.2±3.59% (FW-Ell). Peak systolic strain rate (S') was -1.45±0.39s -1 (FW+S) and -1.54±0.41s -1 (FW). Early diastolic strain rate (E') was 1.04±0.26s -1 (FW+S) and 1.04±0.33s -1 (FW). Late diastolic strain rate (A') was 0.94±0.33s -1 (FW+S) and 1.08±0.33s -1 (FW). RA peak strain was -21.1±3.76%. The intra- and inter-observer ICC for RV Ell (FW+S) was 0.92 and 0.80 respectively, while for RA peak strain was 0.92 and 0.89 respectively. Normal values of RV & RA deformation for healthy individuals using FT-CMR are provided with good RV Ell and RA peak strain reproducibility. Strain rate suffered from sub-optimal reproducibility and may not be satisfactory for clinical use. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
Velocity spectrum for the Iranian plateau
NASA Astrophysics Data System (ADS)
Bastami, Morteza; Soghrat, M. R.
2018-01-01
Peak ground acceleration (PGA) and spectral acceleration values have been proposed in most building codes/guidelines, unlike spectral velocity (SV) and peak ground velocity (PGV). Recent studies have demonstrated the importance of spectral velocity and peak ground velocity in the design of long period structures (e.g., pipelines, tunnels, tanks, and high-rise buildings) and evaluation of seismic vulnerability in underground structures. The current study was undertaken to develop a velocity spectrum and for estimation of PGV. In order to determine these parameters, 398 three-component accelerograms recorded by the Building and Housing Research Center (BHRC) were used. The moment magnitude (Mw) in the selected database was 4.1 to 7.3, and the events occurred after 1977. In the database, the average shear-wave velocity at 0 to 30 m in depth (Vs30) was available for only 217 records; thus, the site class for the remaining was estimated using empirical methods. Because of the importance of the velocity spectrum at low frequencies, the signal-to-noise ratio of 2 was chosen for determination of the low and high frequency to include a wider range of frequency content. This value can produce conservative results. After estimation of the shape of the velocity design spectrum, the PGV was also estimated for the region under study by finding the correlation between PGV and spectral acceleration at the period of 1 s.
Alcohol- and light-induced electro-oculographic responses: variability and clinical utility.
Marmor, Michael F; Wu, Kathy H C
2005-01-01
The alcohol-induced electro-oculographic (EOG) response has been proposed by Arden as an indicator of retinal pigment epithelial (RPE) integrity. We have evaluated the consistency of the alcohol-EOG with respect to clinical applicability and compared this response to the ISCEV-standard EOG. We recorded, in a group of normal subjects (n=29, 14 men with mean age 42+/-11 years and 15 women with mean age 36+/-13 years), the alcohol response to a single oral dose of ethanol at 160 mg/kg (as 40 proof vodka, drunk in 15 s after 12 h of fasting), followed by an ISCEV-standard EOG 90 min after alcohol administration. Blood alcohol levels were monitored at regular intervals with a breath analyzer. We found a wide range of amplitudes in both light and alcohol responses among participants, from minimal to large values. Subjects had a wide range of blood alcohol concentrations from 0.02 to 0.10%; near the time of the response peak, but there was no relationship between alcohol levels and peak/baseline ratios. In addition, there was no relationship between alcohol peak/baseline ratio and the Arden ratio. Neither the alcohol nor the light response parameters showed any relationship with age or gender. Some of the inter-individual variability in the EOG response to alcohol may reflect variable absorption of oral alcohol. The alcohol-induced EOG has too broad a range of responses to be useful clinically for the one-time evaluation of individual patients. We have similar concerns regarding clinical applications of the standard light-induced EOG.
Lee, G.K.; Antweiler, J.C.; Love, J.D.; Benedict, J.F.
1982-01-01
A brief geologic reconnaissance and geochemical survey of molybdenum mineralization near Schiestler Peak, Sublette County, Wyo., indicates that molybdenite occurs in this area as disseminations and blebs in granitic or quartz monzonitic rocks intruded by felsic dikes of similar composition. Samples of stream sediments, panned concentrates from stream sediments, soils, rocks, and water were collected in the geochemical survey. Analytical results show that in reconnaissance, panned concentrates are the best of the sample types used in this study to detect molybdenum mineralization. More detailed analysis of the distribution of the molybdenum is best achieved through the collection of rock samples. Hydrothermal alteration is generally not conspicuous in the study area; however, rock samples that contain molybdenite are usually slightly enriched in silver, copper, lead, and in several instances, gold. Conversely, there appear to be negative associations between molybdenum and zinc and between molybdenum and several of the rare-earth elements. Mo concentrations in the rock samples with no visible molybdenite range from undetectable at a sensitivity of 5 parts per million (ppm) to 700 ppm. Mo content in rock samples containing visible molybdenite ranges from 10 ppm to greater than 2,000 ppm. Stream-sediment values range from undetected to 15 ppm; panned concentrates from undetected to 15 ppm; soils from undetected to 20 ppm. Analyses of the water samples indicate Mo concentrations from 0.8 parts per billion (ppb) to 4.8 ppb. As currently understood, this deposit is not extensive or continuous, but drilling to provide information on the vertical extent of mineralization may alter this opinion.
Alvarez-Fernández, Ana; Orera, Irene; Abadía, Javier; Abadía, Anunciación
2007-01-01
A high-performance liquid chromatography-electrospray ionization/mass spectrometry (time of flight) method has been developed for the simultaneous determination of synthetic Fe(III)-chelates used as fertilizers. Analytes included the seven major Fe(III)-chelates used in agriculture, Fe(III)-EDTA, Fe(III)-DTPA, Fe(III)-HEDTA, Fe(III)-CDTA, Fe(III)-o,oEDDHA, Fe(III)-o,pEDDHA, and Fe(III)-EDDHMA, and the method was validated using isotope labeled (57)Fe(III)-chelates as internal standards. Calibration curves had R values in the range 0.9962-0.9997. Limits of detection and quantification were in the ranges 3-164 and 14-945 pmol, respectively. Analyte concentrations could be determined between the limits of quantification and 25 muM (racemic and meso Fe(III)-o,oEDDHA and Fe(III)-EDDHMA) or 50 muM (Fe(III)-EDTA, Fe(III)-HEDTA, Fe(III)-DTPA, Fe(III)-CDTA and Fe(III)-o,pEDDHA). The average intraday repeatability values were approximately 0.5 and 5% for retention time and peak area, respectively, whereas the interday repeatability values were approximately 0.7 and 8% for retention time and peak area, respectively. The method was validated using four different agricultural matrices, including nutrient solution, irrigation water, soil solution, and plant xylem exudates, spiked with Fe(III)-chelate standards and their stable isotope-labeled corresponding chelates. Analyte recoveries found were in the ranges 92-101% (nutrient solution), 89-102% (irrigation water), 82-100% (soil solution), and 70-111% (plant xylem exudates). Recoveries depended on the analyte, with Fe(III)-EDTA and Fe(III)-DTPA showing the lowest recoveries (average values of 87 and 88%, respectively, for all agricultural matrices used), whereas for other analytes recoveries were between 91 and 101%. The method was also used to determine the real concentrations of Fe(III)-chelates in commercial fertilizers. Furthermore, the method is also capable of resolving two more synthetic Fe(III)-chelates, Fe(III)-EDDHSA and Fe(III)-EDDCHA, whose exact quantification is not currently possible because of lack of commercial standards.
Ma, Qi; Yang, Dong-Rong; Xue, Bo-Xin; Wang, Cheng; Chen, Han-Bin; Dong, Yun; Wang, Cai-Shan; Shan, Yu-Xi
2017-07-01
The focus of the present study was to evaluate transrectal real-time tissue elastography (RTE)-targeted two-core biopsy coupled with peak strain index for the detection of prostate cancer (PCa) and to compare this method with 10-core systematic biopsy. A total of 141 patients were enrolled for evaluation. The diagnostic value of peak strain index was assessed using a receiver operating characteristic curve. The cancer detection rates of the two approaches and corresponding positive cores and Gleason score were compared. The cancer detection rate per core in the RTE-targeted biopsy (44%) was higher compared with that in systematic biopsy (30%). The peak strain index value of PCa was higher compared with that of the benign lesion. PCa was detected with the highest sensitivity (87.5%) and specificity (85.5%) using the threshold value of a peak strain index of ≥5.97 with an area under the curve value of 0.95. When the Gleason score was ≥7, RTE-targeted biopsy coupled with peak strain index detected 95.6% of PCa cases, but 84.4% were detected using systematic biopsy. Peak strain index as a quantitative parameter may improve the differentiation of PCa from benign lesions in the prostate peripheral zone. Transrectal RTE-targeted biopsy coupled with peak strain index may enhance the detection of clinically significant PCa, particularly when combined with systematic biopsy.
Mastin, Mark C.; Konrad, Christopher P.; Veilleux, Andrea G.; Tecca, Alison E.
2016-09-20
An investigation into the magnitude and frequency of floods in Washington State computed the annual exceedance probability (AEP) statistics for 648 U.S. Geological Survey unregulated streamgages in and near the borders of Washington using the recorded annual peak flows through water year 2014. This is an updated report from a previous report published in 1998 that used annual peak flows through the water year 1996. New in this report, a regional skew coefficient was developed for the Pacific Northwest region that includes areas in Oregon, Washington, Idaho and western Montana within the Columbia River drainage basin south of the United States-Canada border, the coastal areas of Oregon and western Washington, and watersheds draining into Puget Sound, Washington. The skew coefficient is an important term in the Log Pearson Type III equation used to define the distribution of the log-transformed annual peaks. The Expected Moments Algorithm was used to fit historical and censored peak-flow data to the log Pearson Type III distribution. A Multiple Grubb-Beck test was employed to censor low outliers of annual peak flows to improve on the frequency distribution. This investigation also includes a section on observed trends in annual peak flows that showed significant trends (p-value < 0.05) in 21 of 83 long-term sites, but with small magnitude Kendall tau values suggesting a limited monotonic trend in the time series of annual peaks. Most of the sites with a significant trend in western Washington were positive and all the sites with significant trends (three sites) in eastern Washington were negative.Multivariate regression analysis with measured basin characteristics and the AEP statistics at long-term, unregulated, and un-urbanized (defined as drainage basins with less than 5 percent impervious land cover for this investigation) streamgages within Washington and some in Idaho and Oregon that are near the Washington border was used to develop equations to estimate AEP statistics at ungaged basins. Washington was divided into four regions to improve the accuracy of the regression equations; a set of equations for eight selected AEPs and for each region were constructed. Selected AEP statistics included the annual peak flows that equaled or exceeded 50, 20, 10, 4, 2, 1, 0.5 and 0.2 percent of the time equivalent to peak flows for peaks with a 2-, 5-, 10-, 25-, 50-, 100-, 200-, and 500-year recurrence intervals, respectively. Annual precipitation and drainage area were the significant basin characteristics in the regression equations for all four regression regions in Washington and forest cover was significant for the two regression regions in eastern Washington. Average standard error of prediction for the regional regression equations ranged from 70.19 to 125.72 percent for Regression Regions 1 and 2 on the eastern side of the Cascade Mountains and from 43.22 to 58.04 percent for Regression Regions 3 and 4 on the western side of the Cascade Mountains. The pseudo coefficient of determination (where a value of 100 signifies a perfect regression model) ranged from 68.39 to 90.68 for Regression Regions 1 and 2, and 92.35 to 95.44 for Regions 3 and 4.The calculated AEP statistics for the streamgages and the regional regression equations are expected to be incorporated into StreamStats after the publication of this report. StreamStats is the interactive Web-based map tool created by the U.S. Geological Survey to allow the user to choose a streamgage and obtain published statistics or choose ungaged locations where the program automatically applies the regional regression equations and computes the estimates of the AEP statistics.
Kawabe, Takefumi; Tomitsuka, Toshiaki; Kajiro, Toshi; Kishi, Naoyuki; Toyo'oka, Toshimasa
2013-01-18
An optimization procedure of ternary isocratic mobile phase composition in the HPLC method using a statistical prediction model and visualization technique is described. In this report, two prediction models were first evaluated to obtain reliable prediction results. The retention time prediction model was constructed by modification from past respectable knowledge of retention modeling against ternary solvent strength changes. An excellent correlation between observed and predicted retention time was given in various kinds of pharmaceutical compounds by the multiple regression modeling of solvent strength parameters. The peak width of half height prediction model employed polynomial fitting of the retention time, because a linear relationship between the peak width of half height and the retention time was not obtained even after taking into account the contribution of the extra-column effect based on a moment method. Accurate prediction results were able to be obtained by such model, showing mostly over 0.99 value of correlation coefficient between observed and predicted peak width of half height. Then, a procedure to visualize a resolution Design Space was tried as the secondary challenge. An artificial neural network method was performed to link directly between ternary solvent strength parameters and predicted resolution, which were determined by accurate prediction results of retention time and a peak width of half height, and to visualize appropriate ternary mobile phase compositions as a range of resolution over 1.5 on the contour profile. By using mixtures of similar pharmaceutical compounds in case studies, we verified a possibility of prediction to find the optimal range of condition. Observed chromatographic results on the optimal condition mostly matched with the prediction and the average of difference between observed and predicted resolution were approximately 0.3. This means that enough accuracy for prediction could be achieved by the proposed procedure. Consequently, the procedure to search the optimal range of ternary solvent strength achieving an appropriate separation is provided by using the resolution Design Space based on accurate prediction. Copyright © 2012 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Ichoku, Charles; Giglio, Louis; Wooster, Martin J.; Remer, Lorraine A.
2008-01-01
Remote sensing is the most practical means of measuring energy release from large open-air biomass burning. Satellite measurement of fire radiative energy (FRE) release rate or power (FRP) enables distinction between fires of different strengths. Based on a 1-km resolution fire data acquired globally by the MODerate-resolution Imaging Spectro-radiometer (MODIS) sensor aboard the Terra and Aqua satellites from 2000 to 2006, instanteaneous FRP values ranged between 0.02 MW and 1866 MW, with global daily means ranging between 20 and 40 MW. Regionally, at the Aqua-MODIS afternoon overpass, the mean FRP values for Alaska, Western US, Western Australia, Quebec and the rest of Canada are significantly higher than these global means, with Quebec having the overall highest value of 85 MW. Analysis of regional mean FRP per unit area of land (FRP flux) shows that a peak fire season in certain regions, fires can be responsible for up to 0.2 W/m(sup 2) at peak time of day. Zambia has the highest regional monthly mean FRP flux of approximately 0.045 W/m(sup 2) at peak time of day and season, while the Middle East has the lowest value of approximately 0.0005 W/m(sup 2). A simple scheme based on FRP has been devised to classify fires into five categories, to facilitate fire rating by strength, similar to earthquakes and hurricanes. The scheme uses MODIS measurements of FRP at 1-km resolution as follows: catagory 1 (less than 100 MW), category 2 (100 to less than 500 MW), category 3 (500 to less than 1000 MW), category 4 (1000 to less than 1500 MW), catagory 5 (greater than or equal to 1500 MW). In most regions of the world, over 90% of fires fall into category 1, while only less than 1% fall into each of categories 3 to 5, although these proportions may differ significantly from day to day and by season. The frequency of occurence of the larger fires is region specific, and could not be explained by ecosystem type alone. Time-series analysis of the propertions of higher category fires based on MODIS measured FRP from 2002 to 2006 does not show any moticeable trend because of the short time period.
Observation of low magnetic field density peaks in helicon plasma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barada, Kshitish K.; Chattopadhyay, P. K.; Ghosh, J.
2013-04-15
Single density peak has been commonly observed in low magnetic field (<100 G) helicon discharges. In this paper, we report the observations of multiple density peaks in low magnetic field (<100 G) helicon discharges produced in the linear helicon plasma device [Barada et al., Rev. Sci. Instrum. 83, 063501 (2012)]. Experiments are carried out using argon gas with m = +1 right helical antenna operating at 13.56 MHz by varying the magnetic field from 0 G to 100 G. The plasma density varies with varying the magnetic field at constant input power and gas pressure and reaches to its peakmore » value at a magnetic field value of {approx}25 G. Another peak of smaller magnitude in density has been observed near 50 G. Measurement of amplitude and phase of the axial component of the wave using magnetic probes for two magnetic field values corresponding to the observed density peaks indicated the existence of radial modes. Measured parallel wave number together with the estimated perpendicular wave number suggests oblique mode propagation of helicon waves along the resonance cone boundary for these magnetic field values. Further, the observations of larger floating potential fluctuations measured with Langmuir probes at those magnetic field values indicate that near resonance cone boundary; these electrostatic fluctuations take energy from helicon wave and dump power to the plasma causing density peaks.« less
Thermoluminescence solid-state nanodosimetry—the peak 5A/5 dosemeter
Fuks, E.; Horowitz, Y. S.; Horowitz, A.; Oster, L.; Marino, S.; Rainer, M.; Rosenfeld, A.; Datz, H.
2011-01-01
The shape of composite peak 5 in the glow curve of LiF:Mg,Ti (TLD-100) following 90Sr/90Y beta irradiation, previously demonstrated to be dependent on the cooling rate used in the 400°C pre-irradiation anneal, is shown to be dependent on ionisation density in both naturally cooled and slow-cooled samples. Following heavy-charged particle high-ionisation density (HID) irradiation, the temperature of composite peak 5 decreases by ∼5°C and the peak becomes broader. This behaviour is attributed to an increase in the relative intensity of peak 5a (a low-temperature satellite of peak 5). The relative intensity of peak 5a is estimated using a computerised glow curve deconvolution code based on first-order kinetics. The analysis uses kinetic parameters for peaks 4 and 5 determined from ancillary measurements resulting in nearly ‘single-glow peak’ curves for both the peaks. In the slow-cooled samples, owing to the increased relative intensity of peak 5a compared with the naturally cooled samples, the precision of the measurement of the 5a/5 intensity ratio is found to be ∼15 % (1 SD) compared with ∼25 % for the naturally cooled samples. The ratio of peak 5a/5 in the slow-cooled samples is found to increase systematically and gradually through a variety of radiation fields from a minimum value of 0.13±0.02 for 90Sr/90Y low-ionisation density irradiations to a maximum value of ∼0.8 for 20 MeV Cu and I ion HID irradiations. Irradiation by low-energy electrons of energy 0.1–1.5 keV results in values between 1.27 and 0.95, respectively. The increasing values of the ratio of peak 5a/5 with increasing ionisation density demonstrate the viability of the concept of the peak 5a/5 nanodosemeter and its potential in the measurement of average ionisation density in a ‘nanoscopic’ mass containing the trapping centre/luminescent centre spatially correlated molecule giving rise to composite peak 5. PMID:21149323
An embedded stress sensor for concrete SHM based on amorphous ferromagnetic microwires.
Olivera, Jesús; González, Margarita; Fuente, José Vicente; Varga, Rastislav; Zhukov, Arkady; Anaya, José Javier
2014-10-24
A new smart concrete aggregate design as a candidate for applications in structural health monitoring (SHM) of critical elements in civil infrastructure is proposed. The cement-based stress/strain sensor was developed by utilizing the stress/strain sensing properties of a magnetic microwire embedded in cement-based composite (MMCC). This is a contact-less type sensor that measures variations of magnetic properties resulting from stress variations. Sensors made of these materials can be designed to satisfy the specific demand for an economic way to monitor concrete infrastructure health. For this purpose, we embedded a thin magnetic microwire in the core of a cement-based cylinder, which was inserted into the concrete specimen under study as an extra aggregate. The experimental results show that the embedded MMCC sensor is capable of measuring internal compressive stress around the range of 1-30 MPa. Two stress sensing properties of the embedded sensor under uniaxial compression were studied: the peak amplitude and peak position of magnetic switching field. The sensitivity values for the amplitude and position within the measured range were 5 mV/MPa and 2.5 µs/MPa, respectively.
Stereotypical rapid source level regulation in the harbour porpoise biosonar
NASA Astrophysics Data System (ADS)
Linnenschmidt, Meike; Kloepper, Laura N.; Wahlberg, Magnus; Nachtigall, Paul E.
2012-09-01
Some odontocetes and bats vary both click intensity and receiver sensitivity during echolocation, depending on target range. It is not known how this so-called automatic gain control is regulated by the animal. The source level of consecutive echolocation clicks from a harbour porpoise was measured with a hydrophone array while the animal detected an aluminium cylinder at 2, 4 or 8 m distance in a go/no-go paradigm. On-axis clicks had source levels of 145-174 dB re 1 μPa peak-to-peak. During target-present trials the click trains reached comparable source levels independent of the range to the target after three clicks. After an additional click, the source level was reduced for the 2 and 4 m trials until it equalled the one-way transmission loss. During target-absent trials, the source level remained high throughout the entire click train. Given typical values of harbour porpoise inter-click intervals, the source level reduction commenced within a few 100 ms from the first click in the click train. This may indicate a sub-cortically regulated source level regulation in the harbour porpoise.
Finite-fault slip model of the 2011 Mw 5.6 Prague, Oklahoma earthquake from regional waveforms
Sun, Xiaodan; Hartzell, Stephen
2014-01-01
The slip model for the 2011 Mw 5.6 Prague, Oklahoma, earthquake is inferred using a linear least squares methodology. Waveforms of six aftershocks recorded at 21 regional stations are used as empirical Green's functions (EGFs). The solution indicates two large slip patches: one located around the hypocenter with a depth range of 3–5.5 km; the other located to the southwest of the epicenter with a depth range from 7.5 to 9.5 km. The total moment of the solution is estimated at 3.37 × 1024 dyne cm (Mw 5.65). The peak slip and average stress drop for the source at the hypocenter are 70 cm and 90 bars, respectively, approximately one half the values for the Mw 5.8 2011 Mineral, Virginia, earthquake. The stress drop averaged over all areas of slip is 16 bars. The relatively low peak slip and stress drop may indicate an induced component in the origin of the Prague earthquake from deep fluid injection.
Mirea, Oana; Pagourelias, Efstathios D; Duchenne, Jurgen; Bogaert, Jan; Thomas, James D; Badano, Luigi P; Voigt, Jens-Uwe
2018-01-01
In this study, we compared left ventricular (LV) segmental strain measurements obtained with different ultrasound machines and post-processing software packages. Global longitudinal strain (GLS) has proven to be a reproducible and valuable tool in clinical practice. Data about the reproducibility and intervendor differences of segmental strain measurements, however, are missing. We included 63 volunteers with cardiac magnetic resonance-proven infarct scar with segmental LV function ranging from normal to severely impaired. Each subject was examined within 2 h by a single expert sonographer with machines from multiple vendors. All 3 apical views were acquired twice to determine the test-retest and the intervendor variability. Segmental longitudinal peak systolic, end-systolic, and post-systolic strain were measured using 7 vendor-specific systems (Hitachi, Tokyo, Japan; Esaote, Florence, Italy; GE Vingmed Ultrasound, Horten, Norway; Philips, Andover, Massachusetts; Samsung, Seoul, South Korea; Siemens, Mountain View, California; and Toshiba, Otawara, Japan) and 2 independent software packages (Epsilon, Ann Arbor, Michigan; and TOMTEC, Unterschleissheim, Germany) and compared among vendors. Image quality and tracking feasibility differed among vendors (analysis of variance, p < 0.05). The absolute test-retest difference ranged from 2.5% to 4.9% for peak systolic, 2.6% to 5.0% for end-systolic, and 2.5% to 5.0% for post-systolic strain. The average segmental strain values varied significantly between vendors (up to 4.5%). Segmental strain parameters from each vendor correlated well with the mean of all vendors (r 2 range 0.58 to 0.81) but showed very different ranges of values. Bias and limits of agreement were up to -4.6 ± 7.5%. In contrast to GLS, LV segmental longitudinal strain measurements have a higher variability on top of the known intervendor bias. The fidelity of different software to follow segmental function varies considerably. We conclude that single segmental strain values should be used with caution in the clinic. Segmental strain pattern analysis might be a more robust alternative. Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
SU-FF-T-668: A Simple Algorithm for Range Modulation Wheel Design in Proton Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nie, X; Nazaryan, Vahagn; Gueye, Paul
2009-06-01
Purpose: To develop a simple algorithm in designing the range modulation wheel to generate a very smooth Spread-Out Bragg peak (SOBP) for proton therapy.Method and Materials: A simple algorithm has been developed to generate the weight factors in corresponding pristine Bragg peaks which composed a smooth SOBP in proton therapy. We used a modified analytical Bragg peak function based on Monte Carol simulation tool-kits of Geant4 as pristine Bragg peaks input in our algorithm. A simple METLAB(R) Quad Program was introduced to optimize the cost function in our algorithm. Results: We found out that the existed analytical function of Braggmore » peak can't directly use as pristine Bragg peak dose-depth profile input file in optimization of the weight factors since this model didn't take into account of the scattering factors introducing from the range shifts in modifying the proton beam energies. We have done Geant4 simulations for proton energy of 63.4 MeV with a 1.08 cm SOBP for variation of pristine Bragg peaks which composed this SOBP and modified the existed analytical Bragg peak functions for their peak heights, ranges of R{sub 0}, and Gaussian energies {sigma}{sub E}. We found out that 19 pristine Bragg peaks are enough to achieve a flatness of 1.5% of SOBP which is the best flatness in the publications. Conclusion: This work develops a simple algorithm to generate the weight factors which is used to design a range modulation wheel to generate a smooth SOBP in protonradiation therapy. We have found out that a medium number of pristine Bragg peaks are enough to generate a SOBP with flatness less than 2%. It is potential to generate data base to store in the treatment plan to produce a clinic acceptable SOBP by using our simple algorithm.« less
NASA Astrophysics Data System (ADS)
Miyakoshi, H.; Tsuno, S.
2013-12-01
The present method of the EEW system installed in the railway field of Japan predicts seismic ground motions based on the estimated earthquake information about epicentral distances and magnitudes using initial P-waves observed on the surface. In the case of local earthquakes beneath the Tokyo Metropolitan Area, however, a method to directly predict seismic ground motions using P-waves observed in deep boreholes could issue EEWs more simply and surely. Besides, a method to predict seismic ground motions, using S-waves observed in deep boreholes and S-wave velocity structures beneath seismic stations, could show planar distributions of ground motions for train operation control areas in the aftermath of earthquakes. This information is available to decide areas in which the emergency inspection of railway structures should be performed. To develop those two methods, we investigated relationships between peak amplitudes on the surface and those in deep boreholes, using seismic records of KiK-net stations in the Kanto Basin. In this study, we used earthquake accelerograms observed in boreholes whose depths are deeper than the top face of Pre-Neogene basement and those on the surface at 12 seismic stations of KiK-net. We selected 243 local earthquakes whose epicenters are located around the Kanto Region. Those JMA magnitudes are in the range from 4.5 to 7.0. We picked the on-set of P-waves and S-waves using a vertical component and two horizontal components, respectively. Peak amplitudes of P-waves and S-waves were obtained using vertical components and vector sums of two horizontal components, respectively. We estimated parameters which represent site amplification factors beneath seismic stations, using peak amplitudes of S-waves observed in the deep borehole and those on the surface, to minimize the residuals between calculations by the theoretical equation and observations. Correlation coefficients between calculations and observations are high values in the range from 0.8 to 0.9. This result suggests that we could predict ground motions with the high accuracy using peak amplitudes of S-waves in deep boreholes and site amplification factors based on S-wave velocity structures. Also, we estimated parameters which represent radiation coefficients and the P/S velocity ratios around hypocentral regions, using peak amplitudes of P-waves and S-waves observed in deep boreholes, to minimize the residuals between calculations and observations. Correlation coefficients between calculations and observations are slightly lower values in the range from 0.7 to 0.9 than those for site amplification factors. This result suggests that the variability of radiation patterns for individual earthquakes affects the accuracy to predict ground motions using P-waves in deep boreholes.
Laser Induced Damage in Optical Materials: 1979.
1980-07-01
as pre- T -1-1viously reported by Hellwarth. Values n2 ranged from 10 13 esu for acetic acid to 10 esu for carbon disulphide. For these nine liquids a...vibrational frequencies of various surface carbonate complexes [13]. It is interesting to note that our data reveal in general a peak in absorption...this valley. The absorption between 5.5 to 8 pm seems to be due to surface carbonates . However, the absence of absorption at 1070 cmŕ signals that the
Antigiardial activity of glycoproteins and glycopeptides from Ziziphus honey.
Mohammed, Seif Eldin A; Kabashi, Ahmed S; Koko, Waleed S; Azim, M Kamran
2015-01-01
Natural honey contains an array of glycoproteins, proteoglycans and glycopeptides. Size-exclusion chromatography fractionated Ziziphus honey proteins into five peaks with molecular masses in the range from 10 to >200 kDa. The fractionated proteins exhibited in vitro activities against Giardia lamblia with IC50 values ≤ 25 μg/mL. Results indicated that honey proteins were more active as antiprotozoal agents than metronidazole. This study indicated the potential of honey proteins and peptides as novel antigiardial agents.
Cosmology constraints from shear peak statistics in Dark Energy Survey Science Verification data
NASA Astrophysics Data System (ADS)
Kacprzak, T.; Kirk, D.; Friedrich, O.; Amara, A.; Refregier, A.; Marian, L.; Dietrich, J. P.; Suchyta, E.; Aleksić, J.; Bacon, D.; Becker, M. R.; Bonnett, C.; Bridle, S. L.; Chang, C.; Eifler, T. F.; Hartley, W. G.; Huff, E. M.; Krause, E.; MacCrann, N.; Melchior, P.; Nicola, A.; Samuroff, S.; Sheldon, E.; Troxel, M. A.; Weller, J.; Zuntz, J.; Abbott, T. M. C.; Abdalla, F. B.; Armstrong, R.; Benoit-Lévy, A.; Bernstein, G. M.; Bernstein, R. A.; Bertin, E.; Brooks, D.; Burke, D. L.; Carnero Rosell, A.; Carrasco Kind, M.; Carretero, J.; Castander, F. J.; Crocce, M.; D'Andrea, C. B.; da Costa, L. N.; Desai, S.; Diehl, H. T.; Evrard, A. E.; Neto, A. Fausti; Flaugher, B.; Fosalba, P.; Frieman, J.; Gerdes, D. W.; Goldstein, D. A.; Gruen, D.; Gruendl, R. A.; Gutierrez, G.; Honscheid, K.; Jain, B.; James, D. J.; Jarvis, M.; Kuehn, K.; Kuropatkin, N.; Lahav, O.; Lima, M.; March, M.; Marshall, J. L.; Martini, P.; Miller, C. J.; Miquel, R.; Mohr, J. J.; Nichol, R. C.; Nord, B.; Plazas, A. A.; Romer, A. K.; Roodman, A.; Rykoff, E. S.; Sanchez, E.; Scarpine, V.; Schubnell, M.; Sevilla-Noarbe, I.; Smith, R. C.; Soares-Santos, M.; Sobreira, F.; Swanson, M. E. C.; Tarle, G.; Thomas, D.; Vikram, V.; Walker, A. R.; Zhang, Y.; DES Collaboration
2016-12-01
Shear peak statistics has gained a lot of attention recently as a practical alternative to the two-point statistics for constraining cosmological parameters. We perform a shear peak statistics analysis of the Dark Energy Survey (DES) Science Verification (SV) data, using weak gravitational lensing measurements from a 139 deg2 field. We measure the abundance of peaks identified in aperture mass maps, as a function of their signal-to-noise ratio, in the signal-to-noise range 04 would require significant corrections, which is why we do not include them in our analysis. We compare our results to the cosmological constraints from the two-point analysis on the SV field and find them to be in good agreement in both the central value and its uncertainty. We discuss prospects for future peak statistics analysis with upcoming DES data.
Structural and functional predictors of regional peak pressures under the foot during walking.
Morag, E; Cavanagh, P R
1999-04-01
The objective of this study was to identify structural and functional factors which are predictors of peak pressure underneath the human foot during walking. Peak plantar pressure during walking and eight data sets of structural and functional measures were collected on 55 asymptomatic subjects between 20 and 70 yr. A best subset regression approach was used to establish models which predicted peak regional pressure under the foot. Potential predictor variables were chosen from physical characteristics, anthropometric data, passive range of motion (PROM), measurements from standardized weight bearing foot radiographs, mechanical properties of the plantar soft tissue, stride parameters, foot motion in 3D, and EMG during walking. Peak pressure values under the rearfoot, midfoot, MTH1, and hallux were measured. Heel pressure was a function of linear kinematics, longitudinal arch structure, thickness of plantar soft tissue, and age. Midfoot pressure prediction was dominated by arch structure, while MTH1 pressure was a function of radiographic measurements, talo-crural joint motion, and gastrocnemius activity. Hallux pressure was a function of structural measures and MTP1 joint motion. Foot structure and function predicted only approximately 50% of the variance in peak pressure, although the relative contributions in different anatomical regions varied dramatically. Structure was dominant in predicting peak pressure under the midfoot and MTH1, while both structure and function were important at the heel and hallux. The predictive models developed in this study give insight into potential etiological factors associated with elevated plantar pressure. They also provide direction for future studies designed to reduce elevated pressure in "at-risk" patients.
Awada, Hassan K; Fletter, Paul C; Zaszczurynski, Paul J; Cooper, Mitchell A; Damaser, Margot S
2015-08-01
The objective of this study was to compare the simultaneous responses of water-filled (WFC) and air-charged (ACC) catheters during simulated urodynamic pressures and develop an algorithm to convert peak pressures measured using an ACC to those measured by a WFC. Examples of cough leak point pressure and valsalva leak point pressure data (n = 4) were obtained from the literature, digitized, and modified in amplitude and duration to create a set of simulated data that ranged in amplitude from 15 to 220 cm H2 O (n = 25) and duration from 0.1 to 3.0 sec (n = 25) for each original signal. Simulated pressure signals were recorded simultaneously by WFCs, ACCs, and a reference transducer in a specially designed pressure chamber. Peak pressure and time to peak pressure were calculated for each simulated pressure signal and were used to develop an algorithm to convert peak pressures recorded with ACCs to corresponding peak pressures recorded with WFCs. The algorithm was validated with additional simulated urodynamic pressure signals and additional catheters that had not been utilized to develop the algorithm. ACCs significantly underestimated peak pressures of more rapidly changing pressures, as in coughs, compared to those measured by WFCs. The algorithm corrected 90% of peak pressures measured by ACCs to within 5% of those measured by WFCs when simultaneously exposed to the same pressure signals. The developed algorithm can be used to convert rapidly changing urodynamic pressures, such as cough leak point pressure, obtained using ACC systems to corresponding values expected from WFC systems. © 2014 Wiley Periodicals, Inc.
Saro, Cristina; Molina-Alcaide, Eduarda; Abecia, Leticia; Ranilla, María José; Carro, María Dolores
2018-04-01
The objective of this study was to compare the automated ribosomal intergenic spacer analysis (ARISA) and the denaturing gradient gel electrophoresis (DGGE) techniques for analysing the effects of diet on diversity in bacterial pellets isolated from the liquid (liquid-associated bacteria (LAB)) and solid (solid-associated bacteria (SAB)) phase of the rumen. The four experimental diets contained forage to concentrate ratios of 70:30 or 30:70 and had either alfalfa hay or grass hay as forage. Four rumen-fistulated animals (two sheep and two goats) received the diets in a Latin square design. Bacterial pellets (LAB and SAB) were isolated at 2 h post-feeding for DNA extraction and analysed by ARISA and DGGE. The number of peaks in individual samples ranged from 48 to 99 for LAB and from 41 to 95 for SAB with ARISA, and values of DGGE-bands ranged from 27 to 50 for LAB and from 18 to 45 for SAB. The LAB samples from high concentrate-fed animals tended (p < 0.10) to show greater peak numbers and Shannon index values than those isolated from high forage-fed animals with ARISA, but no differences were identified with DGGE. The SAB samples from high concentrate-fed animals had lower (p < 0.05) peak numbers and Shannon index values than those from animals fed high-forage diets with ARISA, but only a trend was noticed for these parameters with DGGE (p < 0.10). The ARISA detected that animals fed alfalfa hay diets showed lower (p < 0.05) SAB diversity than those fed grass hay diets, but no differences were observed with DGGE. No effect of forage type on LAB diversity was detected by any technique. In this study, ARISA detected some changes in ruminal bacterial communities that were not detected by DGGE, and therefore ARISA was considered more appropriate for assessing bacterial diversity of ruminal bacterial pellets. The results highlight the impact of the fingerprinting technique used to draw conclusions on dietary factors affecting bacterial diversity in ruminal bacterial pellets.
Zhang, Lina; Zhuang, Ling; Shi, Chang; Miao, Yanwei; Zhang, Weisheng; Song, Qingwei; Kang, Jianyun; Lang, Zhijin; Xin, Xuegang; Liu, Ailian; Hu, Jiani
2017-08-07
Solid papillary carcinoma (SPC) is a rare variant of breast papillary carcinoma with unique pathological morphology and biological behavior. There is only one case report on T 1 -MRI of SPC. In this study, we report our findings on this new category of papillary carcinoma to fill the gap in MRI characterization of SPC. This retrospective study included four pathology-confirmed in situ SPC patients. Conventional MRI, diffusion weighted imaging (DWI), and magnetic resonance spectroscopy (MRS) were performed with a 1.5 T whole-body MR scanner before surgical operation. The following characteristics of each lesion were recorded: signal intensity on T 2 WI/STIR and T 1 FSPGR, morphology, maximum lesion size, and time intensity curve (TIC) on dynamic contrast enhancement MRI (DCE-MRI), apparent diffusion coefficient (ADC) value from DWI, and Cho peak from MRS. Signal intensities of all lesions were heterogenous on T 2 WI/STIR and T 1 FSPGR. Mass enhancements were observed for all lesions with either oval or irregular shapes on DCE-MRI. The maximum lesion size ranged from 0.8 cm to 3.2 cm. All lesion margins were circumscribed, and internal enhancements were homogeneous or heterogeneous from DCE-MRI. TIC appeared with a rapid increase in initial contrast phases of all lesions. All lesions on DWI (b = 1000s/mm 2 ) were slightly hyperintense with an ADC value range of 1.3 × 10 -3 mm 2 /s to 1.9 × 10 -3 mm 2 /s. Cho peak was absent at 3.2 ppm for all lesions. MRI characteristics of SPC include heterogeneous signal intensity within the lesion on T 2 WI/STIR and T 1 FSPGR, mass enhancement with circumscribed margins, either oval or irregular shapes, and a rapid initial enhancement of TIC on DCE-MRI. ADC values and the absence of Cho peak may provide valuable information to distinguish SPC from other invasive breast carcinomas.
NASA Astrophysics Data System (ADS)
Majumdar, Sayantan; Sood, A. K.
2014-06-01
The role of elastic Taylor-Couette flow instabilities in the dynamic nonlinear viscoelastic response of an entangled wormlike micellar fluid is studied by large-amplitude oscillatory shear (LAOS) rheology and in situ polarized light scattering over a wide range of strain and angular frequency values, both above and below the linear crossover point. Well inside the nonlinear regime, higher harmonic decomposition of the resulting stress signal reveals that the normalized third harmonic I3/I1 shows a power-law behavior with strain amplitude. In addition, I3/I1 and the elastic component of stress amplitude σ0E show a very prominent maximum at the strain value where the number density (nv) of the Taylor vortices is maximum. A subsequent increase in applied strain (γ) results in the distortions of the vortices and a concomitant decrease in nv, accompanied by a sharp drop in I3 and σ0E. The peak position of the spatial correlation function of the scattered intensity along the vorticity direction also captures the crossover. Lissajous plots indicate an intracycle strain hardening for the values of γ corresponding to the peak of I3, similar to that observed for hard-sphere glasses.
[UV-Vis spectrum characteristics of phycocyanin in water from Taihu lake].
Zhang, Jing; Wei, Yu-Chun; Wang, Guo-Xiang; Cheng, Chun-Mei; Xia, Xiao-Rui
2014-05-01
The present paper analyzed the UV-Vis spectrum characteristics of phycocyanin extracted from 75 water samples around Meiliang Bay of Taihu Lake, China in spring, summer and autumn, 2011, taking standard sample of phycocyanin, Micro-cystic aeruginosa and Anabaena cultured indoor as the reference, and discussed the difference and relation of spectrum among water samples, standard sample and single algae samples. According to the number of absorption peak in the wavelength range from 500 to 700 nm, phycocyanin spectrum of water sampling in Taihu Lake can be divided into three patterns: no peak, single peak and two peaks. In the first pattern, the absorbance changed smoothly and no absorption peak was observed around 620 nm. Depending on the absorption difference in the wavelength range from 300 to 450 nm, this pattern can be divided into type I and type II. Type I only had a absorption peak near 260 nm, with the similar spectrum of chromophoric dissolved organic matter (CDOM) in the wavelength range from 250 to 800 nm. Type II had absorption peak respectively near 260 and 330 nm. In single peak pattern and two peaks pattern, significant absorption peak of phycocyanin appeared around 620 nm. Compared to the other patterns, single peak pattern was more similar to that of standard sample and single algae samples, but different in their maximum absorption peaks position and relative absorption intensity in the wavelength range of 250 approximately 300, 300 approximately 450 and 500 approximately 700 nm, because of different algae species and purity after extraction. In the two peaks pattern, another absorption peak appeared at 670nm, with the absorption shoulder from 350 to 450 nm, and shared the absorption characteristics of phycocyanin and chlorophyll complex protein. The research can provide a basic support for the phycocyanin quantitation and blooms monitoring in Taihu Lake.
Georgakarakos, Efstratios; Xenakis, Antonios; Georgiadis, George S
2018-02-01
We conducted a computational study to assess the hemodynamic impact of variant main body-to-iliac limb length (L1/L2) ratios on certain hemodynamic parameters acting on the endograft (EG) either on the normal bifurcated (Bif) or the cross-limb (Cx) fashion. A customary bifurcated 3D model was computationally created and meshed using the commercially available ANSYS ICEM (Ansys Inc., Canonsburg, PA, USA) software. The total length of the EG, was kept constant, while the L1/L2 ratio ranged from 0.3 to 1.5 in the Bif and Cx reconstructed EG models. The compliance of the graft was modeled using a Fluid Structure Interaction method. Important hemodynamic parameters such as pressure drop along EG, wall shear stress (WSS) and helicity were calculated. The greatest pressure decrease across EG was calculated in the peak systolic phase. With increasing L1/L2 it was found that the Pressure Drop was increasing for the Cx configuration, while decreasing for the Bif. The greatest helicity (4.1 m/s2) was seen in peak systole of Cx with ratio of 1.5 whereas its greatest value (2 m/s2) was met in peak systole in the Bif with the shortest L1/L2 ratio (0.3). Similarly, the maximum WSS value was highest (2.74Pa) in the peak systole for the 1.5 L1/L2 of the Cx configuration, while the maximum WSS value equaled 2 Pa for all length ratios of the Bif modification (with the WSS found for L1/L2=0.3 being marginally higher). There was greater discrepancy in the WSS values for all L1/L2 ratios of the Cx bifurcation compared to Bif. Different L1/L2 rations are shown to have an impact on the pressure distribution along the entire EG while the length ratio predisposing to highest helicity or WSS values is also determined by the iliac limbs pattern of the EG. Since current custom-made EG solutions can reproduce variability in main-body/iliac limbs length ratios, further computational as well as clinical research is warranted to delineate and predict the hemodynamic and clinical effect of variable length ratios.
Notes about Alta Vista in Chalchihuites, Zacatecas
NASA Astrophysics Data System (ADS)
Montero García, Ismael Arturo
2016-11-01
The Tropic of Cancer is a parallel located at the latitude of 23°26'16''. This imaginary line extends across northern Mexico from the southernmost point of the Baja California Peninsula, to the Gulf of Mexico, passing through the states of Baja California Sur, Sinaloa, Durango, Zacatecas, San Luis Potosí, Nuevo León and Tamaulipas. The Tropic of Cancer marks the northernmost position of the sun at its midday zenith, which takes place in the Summer solstice. On this day, the sun's rays hit the earth's surface vertically along the entire length of this latitude, which was supposed to be significant for the priest/astronomers of ancient times, who dedicated themselves to observing the apparent movements of the sun. It so happens that Alta Vista in Zacatecas, corresponds to the westernmost peak where this phenomenon can occur, although the date of the zenith's course differs depending on the latitude of each position and so various archaeoastronomical specialists stress how the ancient indigenous cultures, at least those dating from Mexico's Classical period, valued this finding in developing their calendars. On the other hand, the research contributes new elements for discussion because it presents a calendar of the horizon, based on of the highest peaks of the Sierra Prieta mountain range ranging from the archaeological sites of El Chapín, Cerro Pedregoso, to the excavations at El Picacho Pelón (peak El Pelón).
Horowitz, Y S; Oster, L; Satinger, D; Biderman, S; Einav, Y
2002-01-01
The hypothesis that glow peak 5a arises from localised e-h capture is confirmed by the following experimental observations: (i) The high conversion efficiency (CE) (CE5a-->4 = 3 +/- 0.5) of peak 5a to peak 4 (a hole-only trap) deduced from detailed Im-Tstop optical bleaching studies at 310 nm compared to the much lower CE of peak 5 (an electron-only trap) (CE5-->4 = 0.0026+/-0.012). (ii) The lack of an increase in the sensitivity of glow peak 5a following 2.6 MeV and 6.8 MeV He ion irradiation in 'sensitised' material compared to the factor two increase in the sensitivity of peak 5; (S/S0)5a = 0.86+/-0.12, compared to (S/S0)5 = 2.0+/-0.2. (iii) The late entry into saturation of the 2.6 MeV and 6.8 MeV He ion TL-fluence response curves for peak 5a compared to peak 5 in sensitised and normal material resulting in the following values for the track radial saturation parameter: (r50)5a = 100+/-20) Angstroms compared to (r50)5 = 380+/-30 Angstroms. (iv) The low value of 0.1 for the 'track-escape' parameter of peak 5a deduced from the Extended Track Interaction Model analysis of He ion TL fluence response compared to order of magnitude greater values for peaks 5 and 5b.
Use of the fluorescence of rhodamine B for the pH sensing of a glycine solution
NASA Astrophysics Data System (ADS)
Zhang, Weiwei; Shi, Kaixing; Shi, Jiulin; He, Xingdao
2016-10-01
The fluorescence of rhodamine B can be strongly affected by its environmental pH value. By directly introducing the dye into various glycine solution, the fluorescence was used to monitor the pH value in the range of 5.9 6.7. Two newly developed techniques for broadband analysis, the barycenter technique and the self-referenced intensity ratio technique, were employed to retrieve the pH sensing functions. While compared with traditional techniques, e.g. the peak shift monitoring, both the two new techniques presented finer precision. The obtained sensing functions may find their applications in the test of biochemical samples, body tissue fluid, water quality, etc.
Fu, Hai-Yan; Guo, Jun-Wei; Yu, Yong-Jie; Li, He-Dong; Cui, Hua-Peng; Liu, Ping-Ping; Wang, Bing; Wang, Sheng; Lu, Peng
2016-06-24
Peak detection is a critical step in chromatographic data analysis. In the present work, we developed a multi-scale Gaussian smoothing-based strategy for accurate peak extraction. The strategy consisted of three stages: background drift correction, peak detection, and peak filtration. Background drift correction was implemented using a moving window strategy. The new peak detection method is a variant of the system used by the well-known MassSpecWavelet, i.e., chromatographic peaks are found at local maximum values under various smoothing window scales. Therefore, peaks can be detected through the ridge lines of maximum values under these window scales, and signals that are monotonously increased/decreased around the peak position could be treated as part of the peak. Instrumental noise was estimated after peak elimination, and a peak filtration strategy was performed to remove peaks with signal-to-noise ratios smaller than 3. The performance of our method was evaluated using two complex datasets. These datasets include essential oil samples for quality control obtained from gas chromatography and tobacco plant samples for metabolic profiling analysis obtained from gas chromatography coupled with mass spectrometry. Results confirmed the reasonability of the developed method. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Davis, L. C.
2013-09-01
A model that includes the mechanical response of a vehicle to a demanded change in acceleration is analyzed to determine the string stability of a platoon of autonomous vehicles. The response is characterized by a first-order time constant τ and an explicit delay td. The minimum value of the acceleration feedback control gain is found from calculations of the velocity of vehicles following a lead vehicle that decelerates sharply from high speed to low speed. Larger values of ξ (in the stable range) give larger values of deceleration for vehicles in the platoon. Optimal operation is attained close to the minimum value of ξ for stability. Small oscillations are found after the main peak in deceleration for ξ in the stable region but near the transition to instability. A theory for predicting the frequency and amplitude of the oscillations is presented.
NASA Astrophysics Data System (ADS)
Liu, Yun; Chen, Sow-Hsin; Berti, Debora; Baglioni, Piero; Alatas, Ahmet; Sinn, Harald; Alp, Ercan; Said, Ayman
2005-12-01
The phonon propagation and damping along the axial direction of films of aligned 40wt% calf-thymus DNA rods are studied by inelastic x-ray scattering (IXS). The IXS spectra are analyzed with the generalized three effective eigenmode theory, from which we extract the dynamic structure factor S (Q,E) as a function of transferred energy E =ℏω, and the magnitude of the transferred wave vector Q. S (Q,E) of a DNA sample typically consists of three peaks, one central Rayleigh scattering peak, and two symmetric Stokes and anti-Stokes Brillouin side peaks. By analyzing the Brillouin peaks, the phonon excitation energy and damping can be extracted at different Q values from about 4 to 30nm-1. A high-frequency sound speed is obtained from the initial slope of the linear portion of the dispersion relation below Q =4nm-1. The high-frequency sound speed obtained in this Q range is 3100m /s, which is about twice faster than the ultrasound speed of 1800m/s, measured by Brillouin light scattering at Q ˜0.01nm-1 at the similar hydration level. Our observations provide further evidence of the strong coupling between the internal dynamics of a DNA molecule and the dynamics of the solvent. The effect on damping and propagation of phonons along the axial direction of DNA rods due to divalent and trivalent counterions has been studied. It is found that the added multivalent counterions introduce stronger phonon damping. The phonons at the range between ˜12.5 and ˜22.5nm-1 are overdamped by the added counterions according to our model analyses. The intermediate scattering function is extracted and it shows a clear two-step relaxation with the fast relaxation time ranging from 0.1 to 4ps.
Slater, Lindsay V; Hart, Joseph M; Kelly, Adam R; Kuenze, Christopher M
2017-09-01
Anterior cruciate ligament (ACL) injury and ACL reconstruction (ACLR) result in persistent alterations in lower extremity movement patterns. The progression of lower extremity biomechanics from the time of injury has not been described. To compare the 3-dimensional (3D) lower extremity kinematics and kinetics of walking among individuals with ACL deficiency (ACLD), individuals with ACLR, and healthy control participants from 3 to 64 months after ACLR. We searched PubMed and Web of Science from 1970 through 2013. We selected only articles that provided peak kinematic and kinetic values during walking in individuals with ACLD or ACLR and comparison with a healthy control group or the contralateral uninjured limb. A total of 27 of 511 identified studies were included. Weighted means, pooled standard deviations, and 95% confidence intervals were calculated for the healthy control, ACLD, and ACLR groups at each reported time since surgery. The magnitude of between-groups (ACLR versus ACLD, control, or contralateral limb) differences at each time point was evaluated using Cohen d effect sizes and associated 95% confidence intervals. Peak knee-flexion angle (Cohen d = -0.41) and external knee-extensor moment (Cohen d = -0.68) were smaller in the ACLD than in the healthy control group. Peak knee-flexion angle (Cohen d range = -0.78 to -1.23) and external knee-extensor moment (Cohen d range = -1.39 to -2.16) were smaller in the ACLR group from 10 to 40 months after ACLR. Reductions in external knee-adduction moment (Cohen d range = -0.50 to -1.23) were present from 9 to 42 months after ACLR. Reductions in peak knee-flexion angle, external knee-flexion moment, and external knee-adduction moment were present in the ACLD and ACLR groups. This movement profile during the loading phase of gait has been linked to knee-cartilage degeneration and may contribute to the development of osteoarthritis after ACLR.
Green urea synthesis catalyzed by hematite nanowires in magnetic field
NASA Astrophysics Data System (ADS)
Yahya, Noorhana; Qureshi, Saima; Rehman, Zia ur; Alqasem, Bilal; Fai Kait, Chong
2017-04-01
The catalytic activity of hematite (α-Fe2O3) nanowires under the influence of magnetic field on urea synthesis is considered green. The adsorption and subsequent dissociative reaction of hydrogen, nitrogen and carbon dioxide gases on the α-Fe2O3 (111) nanowires were investigated using the density functional theory (DFT) method. The average adsorption energy is -4.12 kcal/mole at different sites. The adsorption of gases resulted in a difference in density and net spin of electrons from 68 to 120 and 0-21 respectively. In addition, it induces magnetic moment value of 36.33 μB, which confirms the enhanced magnetic behaviour of hematite. α-Fe2O3 nanowires (NWs) synthesized by heating iron wire in a box furnace at (750-800) °C and as synthesized α-Fe2O3 nanoparticles (NPs) were received to use as a catalyst in the magnetic reaction of urea synthesis. X-ray Diffractometer (XRD) confirms the peaks of rhombohedral structure of α-Fe2O3 and Raman spectrum analyses confirms the α-Fe2O3 peaks at 410 cm-1, 500 cm-1 and 616 cm-1. The needle-like shape of hematite nanowires with length ranging from 16-25) μm and diameter from 74 to 145 nm confirmed by Field emission scanning electron microscopy (FESEM). The magnetic properties of the nanowires exhibited different levels of saturation magnetization, for α-Fe2O3 perpendicularly aligned direction (13.18 emu/g) and random direction (10.73 emu/g). Urea synthesis was done under magnetic field ranges from 0.0 to 2.5 T. The activation energy of α-Fe2O3 NWs for urea production is lower than NPs in the range of 0-1 T, whereas it is reversed for higher magnetic induction values. Fourier transform infrared spectroscopy (FTIR) confirmed the formation of urea at the peaks of 1690-1600 cm-1. This green urea employing magnetically induced method could be a contender to the Haber-Bosch process currently used by the current industry which utilizes high temperature and high pressure.
[Caloric value and energy allocation of Chloris virgata in northeast grassland].
Guo, J; Wang, R; Wang, W
2001-06-01
The rules of seasonal changes in caloric values of individual plant, stem, and leaves of Chloris virgata were similar, which had two peak values from early July to early August, and then decreased gradually. Those of inflorescence assumed U shape, and had two peak values in early August and middle September, respectively. The seasonal changes in caloric values of dead standing were irregular, and the maximum value was appeared in early August. The seasonal changes in existent energy value of the aboveground parts in Chloris virgata population presented double peak curve. The two peak values were appeared in early August and early September respectively, and the maximum value was 7381.27 kJ.m-2 in early September. The energy allocation in different seasons was leaf > stem in early July, stem > leaf > dead standing in middle July, stem > leaf > inflorescence > dead standing in August, stem > inflorescence > leaf > dead standing in early September, and stem > inflorescence > dead standing > leaf in middle September. The vertical structure of energy in the aboveground parts was that the energy value gradually increased from the earth's surface to 20 cm high, and then decreased. The maximum value, which accounted for 25.75% of energy in the aboveground parts, was appeared in the layer of 10-20 cm high. In the underground parts, the energy value progressively decreased with the increase of depth, and the maximum value, which accounted for 74.21% of energy in the underground parts, was appeared in the layer of 0-10 cm depth.
Pharmacokinetic study of gallocatechin-7-gallate from Pithecellobium clypearia Benth. in rats.
Li, Chao; Song, Xiaowei; Song, Junke; Pang, Xiaocong; Wang, Zhe; Zhao, Ying; Lian, Wenwen; Liu, Ailin; Du, Guanhua
2016-01-01
The pharmacokinetic profile of gallocatechin-7-gallate (J10688) was studied in rats after intravenous administration. Male and female Sprague-Dawley (SD) rats received 1, 3, and 10 mg/kg (i.v.) of J10688 and plasma drug concentrations were determined by a high performance liquid chromatography-mass spectrometry (LC-MS) method. The pharmacokinetic software Data Analysis System (Version 3.0) was used to calculate the pharmacokinetic parameters. For different i.v. doses of J10688, the mean peak plasma concentration (C 0) values ranged from 11.26 to 50.82 mg/L, and mean area under the concentration-time curve (AUC0-t ) values ranged from 1.75 to 11.80 (mg·h/L). J10688 lacked dose-dependent pharmacokinetic properties within doses between 1 and 10 mg/kg, based on the power model. The method developed in this study was sensitive, precise, and stable. The pharmacokinetic properties of J10688 in SD rats were shown to have rapid distribution and clearance values. These pharmacokinetic results may contribute to an improved understanding of the pharmacological actions of J10688.
Extreme Value Theory and the New Sunspot Number Series
NASA Astrophysics Data System (ADS)
Acero, F. J.; Carrasco, V. M. S.; Gallego, M. C.; García, J. A.; Vaquero, J. M.
2017-04-01
Extreme value theory was employed to study solar activity using the new sunspot number index. The block maxima approach was used at yearly (1700-2015), monthly (1749-2016), and daily (1818-2016) scales, selecting the maximum sunspot number value for each solar cycle, and the peaks-over-threshold (POT) technique was used after a declustering process only for the daily data. Both techniques led to negative values for the shape parameters. This implies that the extreme sunspot number value distribution has an upper bound. The return level (RL) values obtained from the POT approach were greater than when using the block maxima technique. Regarding the POT approach, the 110 year (550 and 1100 year) RLs were lower (higher) than the daily maximum observed sunspot number value of 528. Furthermore, according to the block maxima approach, the 10-cycle RL lay within the block maxima daily sunspot number range, as expected, but it was striking that the 50- and 100-cycle RLs were also within that range. Thus, it would seem that the RL is reaching a plateau, and, although one must be cautious, it would be difficult to attain sunspot number values greater than 550. The extreme value trends from the four series (yearly, monthly, and daily maxima per solar cycle, and POT after declustering the daily data) were analyzed with the Mann-Kendall test and Sen’s method. Only the negative trend of the daily data with the POT technique was statistically significant.
Gamma-Ray Emission in Dissipative Pulsar Magnetospheres: from Theory to Fermi Observations
NASA Technical Reports Server (NTRS)
Kalapotharakos, Konstantinos; Harding, Alice K.; Kazanas, Demosthenes
2014-01-01
We compute the patterns of gamma-ray emission due to curvature radiation in dissipative pulsar magnetospheres. Our ultimate goal is to construct macrophysical models that are able to reproduce the observed gamma-ray light curve phenomenology recently published in the Second Fermi Pulsar Catalog. We apply specific forms of Ohm's law on the open field lines using a broad range for the macroscopic conductivity values that result in solutions ranging, from near-vacuum to near-force-free. Using these solutions, we generate model gamma-ray light curves by calculating realistic trajectories and Lorentz factors of radiating particles under the influence of both the accelerating electric fields and curvature radiation reaction. We further constrain our models using the observed dependence of the phase lags between the radio and gamma-ray emission on the gamma-ray peak separation. We perform a statistical comparison of our model radio-lag versus peak-separation diagram and the one obtained for the Fermi standard pulsars. We find that for models of uniform conductivity over the entire open magnetic field line region, agreement with observations favors higher values of this parameter. We find, however, significant improvement in fitting the data with models that employ a hybrid form of conductivity, specifically, infinite conductivity interior to the light cylinder and high but finite conductivity on the outside. In these models the gamma-ray emission is produced in regions near the equatorial current sheet but modulated by the local physical properties. These models have radio lags near the observed values and statistically best reproduce the observed light curve phenomenology. Additionally, they also produce GeV photon cut-off energies.
Air Blasts from Cased and Uncased Explosives
DOE Office of Scientific and Technical Information (OSTI.GOV)
Glenn, L. A.
2016-04-12
The problem of a spherical blast in air is solved using the STUN code. For bare charges, the calculations are shown to be in excellent agreement with previous published results. It is demonstrated that, for an unconfined (uncased) chemical explosive, both range and time to effect scale inversely as the cube root of the yield and directly as the cube root of the ambient air density. It is shown that the peak overpressure decays to roughly 1/10 of ambient pressure in a scaled range of roughly 10 m/kg 1/3 at sea level. At a height of 30 km, where themore » ambient density is a factor of 64 less, the range to the same decay increases to 40 m/kg 1/3 . As a direct result of the scaling a single calculation suffices for all charge sizes and altitudes. Although the close-in results are sensitive to the nature of the explosive source and the equation of state of the air, this sensitivity is shown to virtually disappear at scaled ranges > 0.5 m/kg 1/3 . For cased explosives the case thickness introduces an additional scale factor. Moreover, when the blast wave arrives at the inner case radius the case begins to expand. Fracture occurs when a critical value of the resulting hoop strain is reached, causing the case to shatter into fragments. A model is proposed to describe the size distribution of the fragments and their subsequent motion via drag interaction with the explosion products and ambient air. It is shown that a significant fraction of the charge energy is initially transmitted to the case fragments in the form of kinetic energy; for example, a 1 kg spherical charge with a 5 mm thick steel case has almost 29% of the total charge energy as initial kinetic energy of case fragments. This percentage increases with increasing case thickness and decreases with increasing charge size. The peak overpressure at a given range is 70-85% for cased explosives as compared with uncased and the peak impulse per unit area is 90-95%. The peak overpressure and impulse also decrease rapidly with altitude. The effect of the fragments is to increase lethality. Whereas at a scaled range of 10 m/kg 1/3 , the peak overpressure is an order of magnitude less than the ambient pressure, the number of fragments per unit area is close to 1 m -2 /kg 1/3 , independent of case thickness or altitude. For sufficient ratio of case-to- explosive mass, the number of fragments scales with the cube root of the yield and is independent of case thickness.« less
The basin and range viewed from Borah Peak, Idaho.
Stein, R.S.; Bucknam, R.C.
1985-01-01
Today, more than a hundred years later, Borah Peak has proved to be among those mountains still rising. During the 28 October 1983 M=7 Borah Peak, Idaho, earthquake, the Lost River Range that Borah Peak caps was lifted 20-30 cm relative to distant points, and was tilted downward away from the range-bounding Lost River fault. The downthrown side of the fault, which subsided as much as 120 cm, was also tilted down toward the fault. The similarity between the earthquake deformation and the cumulative deformation preserved by the dip of strata is striking; it tends to confirm Gilbert's notion that Basin-and-Range topography is built by repeated slip events on normal faults that bound the range. The U.S Geological Survey had just published a preliminary volume of 40 research papers on the Borah Peak earthquake, focusing on the surface faulting, seismology, geodesy, hydrology, and geology of the earthquake and tis setting (Stein and Bucknam 1985). Also included is a field guide to the spectacular earthquake landforms, such as sruface rupture, exploratory trench excavations, sand blows, and landslides.
Marsh collapse thresholds for coastal Louisiana estimated using elevation and vegetation index data
Couvillion, Brady R.; Beck, Holly
2013-01-01
Forecasting marsh collapse in coastal Louisiana as a result of changes in sea-level rise, subsidence, and accretion deficits necessitates an understanding of thresholds beyond which inundation stress impedes marsh survival. The variability in thresholds at which different marsh types cease to occur (i.e., marsh collapse) is not well understood. We utilized remotely sensed imagery, field data, and elevation data to help gain insight into the relationships between vegetation health and inundation. A Normalized Difference Vegetation Index (NDVI) dataset was calculated using remotely sensed data at peak biomass (August) and used as a proxy for vegetation health and productivity. Statistics were calculated for NDVI values by marsh type for intermediate, brackish, and saline marsh in coastal Louisiana. Marsh-type specific NDVI values of 1.5 and 2 standard deviations below the mean were used as upper and lower limits to identify conditions indicative of collapse. As marshes seldom occur beyond these values, they are believed to represent a range within which marsh collapse is likely to occur. Inundation depth was selected as the primary candidate for evaluation of marsh collapse thresholds. Elevation relative to mean water level (MWL) was calculated by subtracting MWL from an elevation dataset compiled from multiple data types including light detection and ranging (lidar) and bathymetry. A polynomial cubic regression was used to examine a random subset of pixels to determine the relationship between elevation (relative to MWL) and NDVI. The marsh collapse uncertainty range values were found by locating the intercept of the regression line with the 1.5 and 2 standard deviations below the mean NDVI value for each marsh type. Results indicate marsh collapse uncertainty ranges of 30.7–35.8 cm below MWL for intermediate marsh, 20–25.6 cm below MWL for brackish marsh, and 16.9–23.5 cm below MWL for saline marsh. These values are thought to represent the ranges of inundation depths within which marsh collapse is probable.
NASA Technical Reports Server (NTRS)
Klassen, H. A.
1975-01-01
A low-pressure-ratio centrifugal compressor was tested with nine combinations of three diffuser throat areas and three impeller inducer inlet areas which were 75, 100, and 125 percent of design values. For a given inducer inlet area, increases in diffuser area within the range investigated resulted in increased mass flow and higher peak efficiency. Changes in both diffuser and inducer areas indicated that efficiencies within one point of the maximum efficiency were obtained over a compressor specific speed range of 27 percent. The performance was analyzed of an assumed two-spool open-cycle engine using the 75 percent area inducer with a variable area diffuser.
Sample Introduction Using the Hildebrand Grid Nebulizer for Plasma Spectrometry
1988-01-01
linear dynamic ranges, precision, and peak width were de- termined for elements in methanol and acetonitrile solutions. , (1)> The grid nebulizer was...FIA) with ICP-OES detection were evaluated. Detec- tion limits, linear dynamic ranges, precision, and peak width were de- termined for elements in...Concentration vs. Log Peak Area for Mn, 59 Cd, Zn, Au, Ni in Methanol (CMSC) 3-28 Log Concentration vs. Log Peak Area for Mn, 60 Cd, Au, Ni in
Yang, Seung Yun; Butler, Ian S
2013-12-01
Diamond-anvil cell, pressure-tuning infrared (IR), and Raman microspectroscopic measurements have been undertaken to examine the effects of high pressures up to about 45 kbar on the vibrational spectra of the four DNA bases, adenine, cytosine, guanine, and thymine. Small structural changes were evident for all the four bases, viz., for adenine and cytosine at 28-31 kbar; for guanine at 16-19 kbar; and for thymine at 25-26 kbar. These changes are most likely associated with alterations in the intermolecular hydrogen-bonding interactions. The pressure dependences of the main peaks observed in the IR spectra of the two phases of guanine lie in the -0.07-0.66 (low-pressure phase) and 0.06-0.91 (high-pressure phase) cm⁻¹/kbar ranges. Also, in the Raman spectra of this nucleoside base, the dν/dP values range from -0.07-0.31 (low-pressure phase) to 0.08-0.50 (high-pressure phase) cm⁻¹/kbar. Similar ranges of dν/dP values were obtained for the other three nucleoside bases.
Sim, K S; Teh, V; Tey, Y C; Kho, T K
2016-11-01
This paper introduces new development technique to improve the Scanning Electron Microscope (SEM) image quality and we name it as sub-blocking multiple peak histogram equalization (SUB-B-MPHE) with convolution operator. By using this new proposed technique, it shows that the new modified MPHE performs better than original MPHE. In addition, the sub-blocking method consists of convolution operator which can help to remove the blocking effect for SEM images after applying this new developed technique. Hence, by using the convolution operator, it effectively removes the blocking effect by properly distributing the suitable pixel value for the whole image. Overall, the SUB-B-MPHE with convolution outperforms the rest of methods. SCANNING 38:492-501, 2016. © 2015 Wiley Periodicals, Inc. © Wiley Periodicals, Inc.
Impedance spectroscopic and dielectric properties of nanosized Y2/3Cu3Ti4O12 ceramic
NASA Astrophysics Data System (ADS)
Sharma, Sunita; Yadav, Shiv Sundar; Singh, M. M.; Mandal, K. D.
2014-11-01
Yttrium Copper Titanate (Y2/3Cu3Ti4O12) nanoceramic is structurally analogous to CaCu3Ti4O12 (CCTO). X-ray diffraction (XRD) of Y2/3Cu3Ti4O12 (YCTO) shows the presence of all normal peaks of CCTO. SEM micrograph exhibits the presence of bimodal grains of size ranging from 1-2 μm. Bright field TEM image clearly displays nanocrystalline particle which is supported by presence of a few clear rings in the corresponding selected area electron diffraction (SAED) pattern. It exhibits a high value of dielectric constant (ɛ‧ = 8434) at room temperature and 100 Hz frequency with characteristic relaxation peaks. Impedance and modulus studies revealed the presence of temperature-dependent Maxwell-Wagner type of relaxation in the ceramic.
Bonacini, Maurizio; Shetler, Katerina; Yu, Ira; Osorio, Robert C; Osorio, Robert W
2017-05-01
Acute liver failure after ingestion of toxic mushrooms is a significant medical problem. Most exposures to toxic mushrooms produce no symptoms or only mild gastroenteritis, but some lead to severe hepatic necrosis and fulminant hepatic failure requiring liver transplantation. We aimed to assess mortality from mushroom poisoning and identify variables associated with survival and liver transplantation. We collected information from 27 patients (13 male; median age, 47 years) admitted to the emergency department within 24 hours of ingesting wild mushrooms. They developed severe liver injury (serum levels of transaminases greater than 400 IU/L) and were treated with activated charcoal and N-acetylcysteine at a tertiary medical center in San Francisco, California from January 1997 through December 2014. Viral hepatitis, autoimmune liver disease, acetaminophen, salicylate toxicity, and chronic liver diseases were ruled out for all patients. We analyzed patient demographics, time since ingestion, presenting symptoms, laboratory values, and therapies administered. A good outcome was defined as survival without need for liver transplant. A poor outcome was defined as death or liver transplant. Positive predictive values were calculated, and the χ 2 test was used to analyze dichotomous variables. Liver injury was attributed to ingestion of Amanita phalloides in 24 patients and Amanita ocreata in 3 patients. Twenty-four of the patients ingested mushrooms with meals and 3 patients for hallucinogenic purpose. At 24-48 hours after ingestion, all patients had serum levels of alanine aminotransferase ranging from 554 to 4546 IU/L (median, 2185 IU/L). Acute renal impairment developed in 5 patients. Twenty-three patients survived without liver transplantation, and 4 patients had poor outcomes (1 woman underwent liver transplantation on day 20 after mushroom ingestion, and 3 women died of hepatic failure). Of the 23 patients with peak levels of total bilirubin of 2 mg/dL or more during hospitalization, only 4 had a poor outcome. Peak serum level of aspartate aminotransferase less than 4000 IU/L, peak international normalized ratio less than 2, and a value of serum factor V greater than 30% identified patients with good outcomes with 100% positive predictive value; if these peak values were used as a cutoff, 10 of 27 patients (37%), 7 of 27 patients (26%), and 6 of 12 patients (50%), respectively, could have avoided transfer to a transplant center. In an analysis of 27 patients with hepatocellular damage due to mushroom (Amanita) poisoning and peak levels of total bilirubin greater than 2 mg/dL, the probability of liver transplantation or death is 17%, fulfilling Hy's law. Patients with peak levels of aspartate aminotransferase less than 4000 IU/L can be monitored in a local hospital, whereas patients with higher levels should be transferred to liver transplant centers. Women and older patients were more likely to have a poor outcome than men and younger patients. Copyright © 2017 AGA Institute. Published by Elsevier Inc. All rights reserved.
Exercise capacity in pediatric patients with inflammatory bowel disease.
Ploeger, Hilde E; Takken, Tim; Wilk, Boguslaw; Issenman, Robert M; Sears, Ryan; Suri, Soni; Timmons, Brian W
2011-05-01
To examine exercise capacity in youth with Crohn's disease (CD) and ulcerative colitis (UC). Eleven males and eight females with CD and six males and four females with UC participated. Patients performed standard exercise tests to assess peak power (PP) and mean power (MP) and peak aerobic mechanical power (W(peak)) and peak oxygen uptake (VO(2peak)). Fitness variables were compared with reference data and also correlated with relevant clinical outcomes. Pediatric patients with inflammatory bowel disease had lower PP (∼90% of predicted), MP (∼88% of predicted), W(peak) (∼91% of predicted), and VO(2peak) (∼75% of predicted) compared with reference values. When patients with CD or UC were compared separately to reference values, W(peak) was significantly lower only in the CD group. No statistically significant correlations were found between any exercise variables and disease duration (r = 0.01 to 0.14, P = .47 to .95) or disease activity (r = -0.19 to -0.31, P = .11 to .38), measured by pediatric CD activity index or pediatric ulcerative colitis activity index. After controlling for chronological age, recent hemoglobin levels were significantly correlated with PP (r = 0.45, P = .049), MP (r = 0.63, P = .003), VO(2peak) (r = 0.62, P = .004), and W(peak) (r = 0.70, P = .001). Pediatric patients with inflammatory bowel disease exhibit impaired aerobic and anaerobic exercise capacity compared with reference values. Copyright © 2011 Mosby, Inc. All rights reserved.
Finneran, James J; Branstetter, Brian K; Houser, Dorian S; Moore, Patrick W; Mulsow, Jason; Martin, Cameron; Perisho, Shaun
2014-10-01
Previous measurements of toothed whale echolocation transmission beam patterns have utilized few hydrophones and have therefore been limited to fine angular resolution only near the principal axis or poor resolution over larger azimuthal ranges. In this study, a circular, horizontal planar array of 35 hydrophones was used to measure a dolphin's transmission beam pattern with 5° to 10° resolution at azimuths from -150° to +150°. Beam patterns and directivity indices were calculated from both the peak-peak sound pressure and the energy flux density. The emitted pulse became smaller in amplitude and progressively distorted as it was recorded farther off the principal axis. Beyond ±30° to 40°, the off-axis signal consisted of two distinct pulses whose difference in time of arrival increased with the absolute value of the azimuthal angle. A simple model suggests that the second pulse is best explained as a reflection from internal structures in the dolphin's head, and does not implicate the use of a second sound source. Click energy was also more directional at the higher source levels utilized at longer ranges, where the center frequency was elevated compared to that of the lower amplitude clicks used at shorter range.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kumagai, Tsutaru, E-mail: kumagai.t.af@m.titech.ac.jp; Kishi, Tetsuo; Yano, Tetsuji
2015-03-21
Bubble-containing Nd{sup 3+}-doped tellurite glass microspheres were fabricated by localized laser heating technique to investigate their optical properties for use as microresonators. Fluorescence and excitation spectra measurements were performed by pumping with a tunable CW-Ti:Sapphire laser. The excitation spectra manifested several sharp peaks due to the conventional whispering gallery mode (WGM) when the pumping laser was irradiated to the edge part of the microsphere. However, when the excitation light was irradiated on the bubble position inside the microsphere, “non-WGM excitation” was induced, giving rise to numerous peaks at a broad wavelength range in the excitation spectra. Thus, efficient excitation wasmore » achieved over a wide wavelength range. Lasing threshold excited at the bubble position was much lower than that for the excitation at the edges of the microsphere. The lowest value of the laser threshold was 34 μW for a 4 μm sphere containing a 0.5 μm bubble. Efficiency of the excitation at the bubble position with broadband light was calculated to be 5 times higher than that for the edge of the microsphere. The bubble-containing microsphere enables efficient utilization of broadband light excitation from light-emitting diodes and solar light.« less
Porosity and Permeability of Chondritic Materials
NASA Technical Reports Server (NTRS)
Zolensky, Michael E.; Corrigan, Catherine M.; Dahl, Jason; Long, Michael
1996-01-01
We have investigated the porosity of a large number of chondritic interplanetary dust particles and meteorites by three techniques: standard liquid/gas flow techniques, a new, non-invasive ultrasonic technique, and image processing of backscattered images . The latter technique is obviously best suited to sub-kg sized samples. We have also measured the gas and liquid permeabilities of some chondrites by two techniques: standard liquid/gas flow techniques, and a new, non-destructive pressure release technique. We find that chondritic IDP's have a somewhat bimodal porosity distribution. Peaks are present at 0 and 4% porosity; a tail then extends to 53%. These values suggest IDP bulk densities of 1.1 to 3.3 g/cc. Type 1-3 chondrite matrix porosities range up to 30%, with a peak at 2%. The bulk porosities for type 1-3 chondrites have the same approximate range as exhibited by matrix, indicating that other components of the bulk meteorites (including chondrules and aggregates) have the same average porosity as matrix. These results reveal that the porosity of primitive materials at scales ranging from nanogram to kilogram are similar, implying similar accretion dynamics operated through 12 orders of size magnitude. Permeabilities of the investigated chondrites vary by several orders of magnitude, and there appears to be no simple dependence of permeability with degree of aqueous alteration, or chondrite type.
Demonstration of the need for cardiovascular and pulmonary normative data for cancer survivors.
Schneider, C M; Repka, C P; Brown, J M; Lalonde, T L; Dallow, K T; Barlow, C E; Hayward, R
2014-12-01
Despite evidence that cancer and its treatments severely reduce cardiorespiratory fitness (CRF), normative data for cancer survivors do not exist. The present study identifies age and gender-specific CRF distributions in a cancer population. The use of cancer-specific normative CRF data may help stratify initial fitness status and assess improvements in response to exercise interventions in cancer survivors. Data from 703 cancer survivors were analyzed for this study. Quintiles were compiled for peak oxygen consumption (VO2peak), forced vital capacity (FVC), and forced expiratory volume (FEV1) for males and females in 5 age groups (19-39, 40-49, 50-59, 60-69, and ≥70 years of age). VO2peak values for the cancer population were significantly lower than the general US population. The cancer population average in each age group fell within the "very poor" classification of VO2peak values for the general population. FVC values in the cancer population were similar to the general population. Cancer survivors had very low age group-specific VO2peak values compared to the apparently healthy general US population. Previously, CRF values of cancer survivors were compared to normative values for the apparently healthy general population, which yielded imprecise classifications of initial fitness and changes in fitness, resulting in patient discouragement. © Georg Thieme Verlag KG Stuttgart · New York.
Smectic order induced at homeotropically aligned nematic surfaces: A neutron reflection study
NASA Astrophysics Data System (ADS)
Lau, Y. G. J.; Richardson, Robert M.; Cubitt, R.
2006-06-01
Neutron reflection was used to measure the buildup of layers at a solid surface as the smectic phase is approached from higher temperatures in a nematic liquid crystal. The liquid crystal was 4-octyl-4'-cyanobiphenyl (8CB), and the solid was silicon with one of five different surface treatments that induce homeotropic alignment: (i) silicon oxide; (ii) a cetyltrimethylammonium bromide coating; (iii) an octadecyltrichlorosilane monolayer; (iv) an n-n-dimethyl-n-octadecyl-3- aminopropyltrimethyloxysilyl chloride monolayer; and (v) a lecithin coating. The development of surface smectic layers in the nematic phase of 8CB was followed by measuring specular reflectivity and monitoring the pseudo-Bragg peak from the layers. The scattering data were processed to remove the scattering from short-ranged smecticlike fluctuations in the bulk nematic phase from the specular reflection. The pseudo-Bragg peak at scattering vector Q ˜0.2Å-1 therefore corresponded to the formation of long-range smectic layers at the surface. The amplitude of the smectic density wave decayed with increasing distance from the surface, and the characteristic thickness of this smectic region diverged as the transition temperature was approached. It was found that the characteristic thickness for some of the surface treatments was greater than the correlation length in the bulk nematic. The different surfaces gave different values of the smectic order parameter at the surface. This suggests that the interaction with the surface is significantly different from a "hard wall" which would give the same values of the smectic order parameter and penetration depths similar to the bulk correlation length. Comparison of the different surfaces also suggested that the strength and range of the surface smectic ordering may be varied independently.
Weak Frictional Healing as Controlled by Intergranular Pressure Solution
NASA Astrophysics Data System (ADS)
He, C.
2017-12-01
Unstable fault slips due to velocity weakening requires a frictional healing effect that is stronger than the instantaneous rate effect. Based on a previous analytical result regarding the healing effect at spherical contacts by intergranular pressure solution (He et al., 2013), we extend the analysis to incorporate the full range of dilatancy angles from π/6 to -π/6, covering uphill and downhill situations of many contacts with different dilatancy angles. Assuming that both healing effect (parameter b) and instantaneous rate effect (parameter a) are controlled by intergranular pressure solution, and averaging over the whole range of dilatancy angle, our analysis derives each of the two effects as a function of temperature. The result shows velocity weakening for friction coefficient>0.274. As hydrothermal conditions are important for deep portion of actual fault zones, the strength of velocity weakening is of interest when the related faulting behavior is concerned. As a measure of the strength of velocity weakening, the derived ratio b/a fully controlled by pressure solution shows an upper bound of 1.22. Data analyses in previous studies on plagioclase (He et al., 2013) and oceanic basalt (Zhang and He, 2017) shows a range of b/a =1.05-1.2, consistent with the analytical result. The values<1.2 are considered here to be due to concurrent cataclasis that promotes the instantaneous rate effect, which reduces b/a to levels below the upper bound. These values are significantly less than in dry experiments on granite by Mitchell et al.(2016), where b/a ranges from 1.54-2.59 as inferred by reanalyzing their stick-slip data at temperatures of 20°C, 500°C and 600°C. Comparison between the two ranges of b/a helps understand the dominant mechanism of frictional healing at contacts, especially under hydrothermal conditions in fault zones. For comparable ratios of system stiffness to the critical value, numerical simulations with a single-degree-of-freedom system show that a smaller b/a significantly reduces the peak slip velocity as a result of reduced period of free oscillation corresponding to the lower stiffness (Fig.1). This is an effect similar to that by reduced effective normal stress due to overpressure of pore fluid, which lowers the stiffness suitable for unstable slips, thus weakens the peak slip velocity.
Initial Circulation and Peak Vorticity Behavior of Vortices Shed from Airfoil Vortex Generators
NASA Technical Reports Server (NTRS)
Wendt, Bruce J.; Biesiadny, Tom (Technical Monitor)
2001-01-01
An extensive parametric study of vortices shed from airfoil vortex generators has been conducted to determine the dependence of initial vortex circulation and peak vorticity on elements of the airfoil geometry and impinging flow conditions. These elements include the airfoil angle of attack, chord length, span, aspect ratio, local boundary layer thickness, and free stream Mach number. In addition, the influence of airfoil-to-airfoil spacing on the circulation and peak vorticity has been examined for pairs of co-rotating and counter-rotating vortices. The vortex generators were symmetric airfoils having a NACA-0012 cross-sectional profile. These airfoils were mounted either in isolation, or in pairs, on the surface of a straight pipe. The turbulent boundary layer thickness to pipe radius ratio was about 17 percent. The circulation and peak vorticity data were derived from cross-plane velocity measurements acquired with a seven-hole probe at one chord-length downstream of the airfoil trailing edge location. The circulation is observed to be proportional to the free-stream Mach number, the angle-of-attack, and the span-to-boundary layer thickness ratio. With these parameters held constant, the circulation is observed to fall off in monotonic fashion with increasing airfoil aspect ratio. The peak vorticity is also observed to be proportional to the free-stream Mach number, the airfoil angle-of-attack, and the span-to-boundary layer thickness ratio. Unlike circulation, however, the peak vorticity is observed to increase with increasing aspect ratio, reaching a peak value at an aspect ratio of about 2.0 before falling off again at higher values of aspect ratio. Co-rotating vortices shed from closely spaced pairs of airfoils have values of circulation and peak vorticity under those values found for vortices shed from isolated airfoils of the same geometry. Conversely, counter-rotating vortices show enhanced values of circulation and peak vorticity when compared to values obtained in isolation. The circulation may be accurately modeled with an expression based on Prandtl's relationship between finite airfoil circulation and airfoil geometry. A correlation for the peak vorticity has been derived from a conservation relationship equating the moment at the airfoil tip to the rate of angular momentum production of the shed vortex, modeled as a Lamb (ideal viscous) vortex. This technique provides excellent qualitative agreement to the observed behavior of peak vorticity for low aspect ratio airfoils typically used as vortex generators.
2012-01-01
Background Annual influenza epidemics occur worldwide resulting in considerable morbidity and mortality. Spreading pattern of influenza is not well understood because it is often hampered by the quality of surveillance data that limits the reliability of analysis. In Japan, influenza is reported on a weekly basis from 5,000 hospitals and clinics nationwide under the scheme of the National Infectious Disease Surveillance. The collected data are available to the public as weekly reports which were summarized into number of patient visits per hospital or clinic in each of the 47 prefectures. From this surveillance data, we analyzed the spatial spreading patterns of influenza epidemics using weekly weighted standard distance (WSD) from the 1999/2000 through 2008/2009 influenza seasons in Japan. WSD is a single numerical value representing the spatial compactness of influenza outbreak, which is small in case of clustered distribution and large in case of dispersed distribution. Results We demonstrated that the weekly WSD value or the measure of spatial compactness of the distribution of reported influenza cases, decreased to its lowest value before each epidemic peak in nine out of ten seasons analyzed. The duration between the lowest WSD week and the peak week of influenza cases ranged from minus one week to twenty weeks. The duration showed significant negative association with the proportion of influenza A/H3N2 cases in early phase of each outbreak (correlation coefficient was −0.75, P = 0.012) and significant positive association with the proportion of influenza B cases in the early phase (correlation coefficient was 0.64, P = 0.045), but positively correlated with the proportion of influenza A/H1N1 strain cases (statistically not significant). It is assumed that the lowest WSD values just before influenza peaks are due to local outbreak which results in small standard distance values. As influenza cases disperse nationwide and an epidemic reaches its peak, WSD value changed to be a progressively increasing. Conclusions The spatial distribution of nationwide influenza outbreak was measured by using a novel WSD method. We showed that spreading rate varied by type and subtypes of influenza virus using WSD as a spatial indicator. This study is the first to show a relationship between influenza epidemic trend by type/subtype and spatial distribution of influenza nationwide in Japan. PMID:22713508
Spectral analysis of femoral artery blood flow waveforms of conscious domestic cats.
dos Reis, Gisele F M; Nogueira, Rodrigo B; Silva, Adriana C; Oberlender, Guilherme; Muzzi, Ruthnéa A L; Mantovani, Matheus M
2014-12-01
The qualitative and quantitative aspects of femoral artery blood flow waveform spectra were evaluated in 15 male and 15 female Persian and mixed breed domestic cats (Felis catus), which were healthy and not sedated, using duplex Doppler ultrasonography (DDU). Spectral Doppler demonstrated a biphasic characteristic in 16 (53.34%) of the animals evaluated, and a triphasic characteristic in the 14 (46.66%) remaining animals. The systolic blood pressure and heart rate values were within the normal range for the species. The quantitative parameters evaluated, based on the spectral Doppler, were as follows: systolic velocity peak (SVP), recent diastolic velocity peak (RDVP), end diastolic velocity peak (EDVP), mean velocity (MV), integral velocity time (ITV), artery diameter (AD), femoral flow volume (FFV), pulsatility index (PI), resistive index (RI), systolic peak acceleration time (AT) and deceleration time (DT). The respective mean values were: 36.41 ± 7.33 cm/s, 4.69 ± 0.90 cm/s, 10.74 ± 2.74 cm/s, 23.06 ± 4.86 cm/s, 3.91 ± 1.05 cm, 0.17 ± 0.04 cm, 0.11 ± 0.08 cm(3), 3.85 ± 0.19, 1.40 ± 0.20, 39.84 ± 7.38 ms, and 114.0 ± 22.15 ms. No significant differences were found between males and females. The analyses carried out on the femoral artery flow spectrum obtained by DDU showed that it is easy to use and highly tolerated in non-sedated, healthy cats. It appears that DDU may be a useful diagnostic technique, but further studies are needed to evaluate how it compares with invasive telemetric methodology or high-definition oscillometric waveform analytic techniques. © ISFM and AAFP 2014.
Respiratory trace feature analysis for the prediction of respiratory-gated PET quantification.
Wang, Shouyi; Bowen, Stephen R; Chaovalitwongse, W Art; Sandison, George A; Grabowski, Thomas J; Kinahan, Paul E
2014-02-21
The benefits of respiratory gating in quantitative PET/CT vary tremendously between individual patients. Respiratory pattern is among many patient-specific characteristics that are thought to play an important role in gating-induced imaging improvements. However, the quantitative relationship between patient-specific characteristics of respiratory pattern and improvements in quantitative accuracy from respiratory-gated PET/CT has not been well established. If such a relationship could be estimated, then patient-specific respiratory patterns could be used to prospectively select appropriate motion compensation during image acquisition on a per-patient basis. This study was undertaken to develop a novel statistical model that predicts quantitative changes in PET/CT imaging due to respiratory gating. Free-breathing static FDG-PET images without gating and respiratory-gated FDG-PET images were collected from 22 lung and liver cancer patients on a PET/CT scanner. PET imaging quality was quantified with peak standardized uptake value (SUV(peak)) over lesions of interest. Relative differences in SUV(peak) between static and gated PET images were calculated to indicate quantitative imaging changes due to gating. A comprehensive multidimensional extraction of the morphological and statistical characteristics of respiratory patterns was conducted, resulting in 16 features that characterize representative patterns of a single respiratory trace. The six most informative features were subsequently extracted using a stepwise feature selection approach. The multiple-regression model was trained and tested based on a leave-one-subject-out cross-validation. The predicted quantitative improvements in PET imaging achieved an accuracy higher than 90% using a criterion with a dynamic error-tolerance range for SUV(peak) values. The results of this study suggest that our prediction framework could be applied to determine which patients would likely benefit from respiratory motion compensation when clinicians quantitatively assess PET/CT for therapy target definition and response assessment.
[The lh-rh-test in men with fertility disorders (author's transl)].
Krause, W; Höbel, W
1976-11-01
89 mal patients with fertility disorders underwent a test with 50 mug synthetic LH-RH. The basal levels of FSH and LH are elevated in patients with azoospermia, with testicular atrophy, varicocele and Klinefelters syndrome. They increase with age. After stimulation with LH-RH the highest relative peaks (maximal value divided by control value) of LH are seen younger patients, in those with varicocele, and oligozoospermia. The FSH-values do not differ significantly between these groups. Low relative peaks of LH are seen in older patients. In Klinefelter's syndrome the relative peaks of FSH and LH are significantly lowered.
Sid-Ahmed, Omer-Elfaroug; Sanhouri, Ahmed; Elwaseela, Badr-Eldin; Fadllalah, Imad; Mohammed, Galal-Eldin Elazhari; Möstl, Erich
2013-08-01
The aim of this study was to determine whether glucocorticoid production could be monitored non-invasively in dromedary camels by measuring faecal cortisol metabolites (FCMs). Five Sudanese dromedaries, two males and three females, were injected with a synthetic adrenocorticotropic hormone (ACTH) analogue. Blood samples were collected pre- and post-ACTH injection. Faeces were sampled after spontaneous defecation for five consecutive days (2 days before and 3 days after ACTH injection). Baseline plasma cortisol values ranged from 0.6 to 10.8 ng/ml in males and from 1.1 to 16.6 ng/ml in females, while peak values after ACTH injection were 10.9-41.9 in males and 10-42.2 ng/ml in females. Peak blood cortisol values were reached between 1.5 and 2.0 h after ACTH injection. The concentration of FCMs increased after ACTH injection in the faeces of both sexes, although steroid levels peaked earlier in males [24 h; (286.7-2,559.7 ng/g faeces)] than in females [36-48 h; (1,182.6-5,169.1 ng/g faeces)], reflecting increases of 3.1-8.3- and 4.3-8-fold above baseline levels. To detect chromatographic patterns of immunoreactive FCMs, faecal samples with high FCM concentrations from both sexes were pooled and subjected to reverse phase high performance liquid chromatography (RP-HPLC). RP-HPLC analysis revealed sex differences in the polarity of FCMs, with females showing more polar FCMs than males. We concluded that stimulation of adrenocortical activity by ACTH injection resulted in a measurable increase in blood cortisol that was reliably paralleled by increases in FCM levels. Thus, measurement of FCMs is a powerful tool for monitoring the adrenocortical responses of dromedaries to stressors in field conditions.
NASA Astrophysics Data System (ADS)
Yin, Dawei; Chapman, Glenn H.; Stevens, David; Gray, Bonnie; Leznoff, Daniel
2018-02-01
The detection of ammonia in parts per millions range has been challenging in sensors research, and is of great importance for industrial applications. In previous literature, Vapochromic Coordination Polymers (VCP) were developed to achieve luminescence upon a targeted gas exposures. We investigate a specific VCP, Zn[Au(CN)2]2,as an ammonia sensing material. Upon high concentration ammonia exposure, the fluorescent peak under near-UV stimulation undergoes a spectral shift from 460nm to 520nm, while the intensity increases by 3 4X. However, at ammonia concentrations < 50ppm, the spectral shift becomes hidden within the overall changing fluorescent spectrum shape. Then simple methods, such as detecting the peak wavelength or subtracting post-exposure from pre-exposure spectrums do not work. We developed further excitation and data processing techniques to detect ammonia at lower concentrations. A low-cost 405nm blue-ray DVD laser diode was used as the excitation source, providing a narrow band-width (4nm) stimulation that is separated from the emission peak. We measured the emission using a portable spectrometer (Photon Control SPM-002), and processed the data by separating the spectrum into two regions; (A) from 425 nm to 460 nm and (B) from 460nm to 500nm. Next, the integrated emissions under both regions were computed, and the value of shorter wavelength region (A) was subtracted from the longer wavelength one (B). When exposed to ammonia, region (A) reduces overall intensity while region (B) increases, resulting a signal starting from negative value and gradually increases to positive values, enabling the detection of 5ppm ammonia in less than 30 seconds gas exposure.
NASA Astrophysics Data System (ADS)
Patch, S. K.; Kireeff Covo, M.; Jackson, A.; Qadadha, Y. M.; Campbell, K. S.; Albright, R. A.; Bloemhard, P.; Donoghue, A. P.; Siero, C. R.; Gimpel, T. L.; Small, S. M.; Ninemire, B. F.; Johnson, M. B.; Phair, L.
2016-08-01
The potential of particle therapy due to focused dose deposition in the Bragg peak has not yet been fully realized due to inaccuracies in range verification. The purpose of this work was to correlate the Bragg peak location with target structure, by overlaying the location of the Bragg peak onto a standard ultrasound image. Pulsed delivery of 50 MeV protons was accomplished by a fast chopper installed between the ion source and the cyclotron inflector. The chopper limited the train of bunches so that 2 Gy were delivered in 2 μ \\text{s} . The ion pulse generated thermoacoustic pulses that were detected by a cardiac ultrasound array, which also produced a grayscale ultrasound image. A filtered backprojection algorithm focused the received signal to the Bragg peak location with perfect co-registration to the ultrasound images. Data was collected in a room temperature water bath and gelatin phantom with a cavity designed to mimic the intestine, in which gas pockets can displace the Bragg peak. Phantom experiments performed with the cavity both empty and filled with olive oil confirmed that displacement of the Bragg peak due to anatomical change could be detected. Thermoacoustic range measurements in the waterbath agreed with Monte Carlo simulation within 1.2 mm. In the phantom, thermoacoustic range estimates and first-order range estimates from CT images agreed to within 1.5 mm.
Isokinetic muscle performance of the hip and ankle muscles in women with fibromyalgia.
Yetişgin, Alparslan; Tiftik, Tülay; Kara, Murat; Karabay, İlkay; Akkuş, Selami; Ersöz, Murat
2016-06-01
To compare isokinetic muscle performances of a proximal (hip) and a distal (ankle) muscle of fibromyalgia syndrome (FMS) patients with those of age- and body mass index (BMI)-matched healthy subjects. Thirty female patients with FMS (mean age: 41.5 ± 6.7 years [range, 27-54]) and 30 age- (mean age: 40.6 ± 6.0 years [range, 27-54]) and BMI-matched female healthy controls were consecutively enrolled. Demographic and clinical characteristics of the subjects were recorded. Isokinetic measurements of hip and ankle flexion and extension at angular velocities of 60°/s and 180°/s, peak torques, flexor-extensor torque ratios, muscle fatigue resistance values and average power were obtained. Mean disease duration of FMS patients was 2.4 ± 1.9 years. Mean weight, height and BMI values were 70.4 ± 12.5 kg, 159.5 ± 6.0 cm and 27.7 ± 4.7 kg/m² (FMS patients) and 69.3 ± 10.1 kg, 161.7 ± 6.2 cm and 26.6 ± 4.3 kg/m² (control subjects), respectively (all P > 0.05). All isokinetic values were statistically decreased in the FMS group when compared with the control group, except for the peak torques at angular velocity of 180°/s on flexion of the hip and extension of the ankle and the total work and average power on extension of the ankle. We did not find any correlation between isokinetic values and disease related parameters of FMS patients. In the light of our results, we may conclude that muscle strength and muscle fatigue seem to decrease in FMS patients' both proximal and distal lower extremity muscles. © 2013 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.
MR imaging of intracranial hemangiopericytomas.
Mama, N; Ben Abdallah, A; Hasni, I; Kadri, K; Arifa, N; Ladib, M; Tlili-Graiess, K
2014-12-01
To describe the MR features of primary intracranial hemangiopericytomas (HPCs) on conventional imaging, diffusion and MR spectroscopy and aim to determinate distinguishing features from meningiomas. From 2006 to 2012, seven patients with pathologically confirmed primary intracranial HPCs were included. The clinical data, conventional MR findings (n=7), DWI features (n=7) and MR spectroscopy (n=5) were retrospectively analyzed. ADC values of the HPCs (n=7) were measured on ADC map and were compared with that of contralateral normal white matter. Of the seven HPCs, four were anaplastic HPCs (WHO grade III) and three were HPCs (WHO grade II). MR pattern consisted in lobulated or irregular margin tumors in all cases with cross-leaf growth on both side of the falx in two cases. The lesions showed mainly iso signal (n=4) on T1 WI and heterogeneous high signal (n=5) on T2 WI. Heterogenity was mainly related to intra tumoral hemorrhage (n=4), and proeminent intratumoral flow voids (n=3). Marked heterogeneous enhancement (n=5) with dural tail (n=4) was noted. All tumours showed significant peritumoral edema. ADC values of the tumor tissue component range between 0.638 and 1.50×10(-3)mm/s(2) (average = 1,02). Three grade II HPCs showed higher values compared to normal parenchyma ADC (range between 0.772 and 0.930×10(-3)mm/s(2) with average of 0.830), whereas grade III HPCs showed either equal (three cases) or decreased ADC values (one case). MRS showed in all cases markedly increased Cho with lip/lac peak, decreased Cr and almost absent NAA. High mI peak with large glutamine/glutamate were noted in the three grade II HPCs. Conventional MR pattern when combined with DWI and MRS findings are highly suggestive of HPC and appear valuable data to differentiate HPCs from meningiomas. Copyright © 2014. Published by Elsevier Masson SAS.
Characterization of Viable Fungal Spores in PM 2.5 Filter Samples Reaching the Eastern Caribbean
NASA Astrophysics Data System (ADS)
Detres, Y.; Armstrong, R. A.
2003-12-01
Aerosols from Africa travel across the tropical Atlantic Ocean carrying particulates, microorganisms and other contaminants into the Caribbean region. An air sampling station was installed at Castle Bruce, Dominica on March 31, 2002 and operated continuously until August 1, 2002 for the characterization of fungi species present in the Saharan dust. The sequential air sampler collected PM 2.5 samples, which were subsequently analyzed for fungal spores. The input of aerosols into this region was traced by AVHRR and SeaWiFS satellite imagery as well as by NAAPS and Hysplit models. The climatology of Aerosol Optical Thickness (AOT) data from AVHRR for the study site show higher aerosol concentrations for the period of May through July with peak values during the last week of June. Some filters were used for determination of PM 2.5 concentration by gravimetric analysis. Results ranged from 3.08 to 18.06 ug/m3. The number of colony forming units in the sampled filters ranged from 0.08 to 2.5 m-3 with peak values during the last week of June. Fungal identification to gender level was based on macro and micro morphological features and species characterization was performed using molecular techniques. Among the identified species there are some plant pathogens that affect economically important crops and some human pathogens responsible of serious respiratory diseases. The relation between aerosol optical depth and fungi concentration, as well as the link between these organisms and health issues will be presented.
Small female head and neck interaction with a deploying side airbag.
Duma, Stefan M; Crandall, Jeff R; Rudd, Rodney W; Kent, Richard W
2003-09-01
This paper presents dummy and cadaver experiments designed to investigate the injury potential of an out-of-position small female head and neck from a deploying side airbag. Seat-mounted, thoracic-type, side airbags were selected for this study to represent those currently available on selected luxury automobiles. A computer simulation program was used to identify the worst case loading position for the small female head and neck. Once the initial position was identified, experiments were performed with the Hybrid III 5th percentile dummy and three small female cadavers, using three different inflators. Peak head center of gravity (CG) accelerations for the dummy ranged from 71x g to 154 x g, and were greater than cadaver values, which ranged from 68 x g to 103 x g. Peak neck tension as measured at the upper load cell of the dummy increased with inflator aggressivity from 992 to 1670N. A conservative modification of the US National Highway Traffic Safety Administration's (NHTSA's) N(ij) proposed neck injury criteria, which combines neck tension and bending, was used. All values were well below the 1.0 injury threshold for the dummy and suggested a very low possibility of neck injury. In agreement with this prediction, no injuries were observed. Even in a worst case position, small females are at low risk of head or neck injuries under loading from these thoracic-type airbags; however, injury risk increases with increasing inflator aggressivity.
Aesthetic value improvement of the ruby stone using heat treatment and its synergetic surface study
NASA Astrophysics Data System (ADS)
Sahoo, Rakesh K.; Mohapatra, Birendra K.; Singh, Saroj K.; Mishra, Barada K.
2015-02-01
The surface behavior of the natural ruby stones before and after heat treatment with metal oxide additives like: zinc oxide (ZnO) and lead oxide (PbO) have been studied. The surface appearance of the ruby stones processed with the metal oxides changed whereas the bulk densities of the stones remained within the range of 3.9-4.0 g/cm3. The cracks healing and pores filling by the metal oxides on the surface of the ruby have been examined using scanning electron microscopy. The chemical compositions based on the XPS survey scans are in good agreement with the expected composition. The phase and crystallinity of the ruby stones original and heat-treated were obtained from their X-ray diffraction patterns. The change in peak separation between R1 and R2 - peaks in photoluminescence spectra and the contrary binding energy shift of the Al 2p peaks in the X-ray photoelectron spectra have been explicated. Moreover, in this work we describe the change in surface chemical and physical characteristics of the ruby stone before and after heat treatment.
Desiderio, C; Marra, C; Fanali, S
1998-06-01
The separation of synthetic dyes, used as color additives in cosmetics, by micellar electrokinetic capillary chromatography (MEKC) is described in this study. The separation of seven dyes, namely eosine, erythrosine, cyanosine, rhodamine B, orange II, chromotrope FB and tartrazine has been achieved in about 3 min in an untreated fused silica capillary containing as background electrolyte a 25 mM tetraborate/phosphate buffer, pH 8.0, and 30 mM sodium dodecyl sulfate. The electrophoretic method exhibits precision and relatively high sensitivity. A detection limit (LOD, signal/noise = 3) in the range of 5-7.5 X 10(-7) M of standard compounds was recorded. Intra-day repeatability of all the studied dye determinations (8 runs) gave the following results (limit values), % standard deviation: 0.24-1.54% for migration time, 0.99-1.24% for corrected peak areas, 0.99-1.24% for corrected peak area ratio (analyte/internal standard) and 1.56-2.74% for peak areas. The optimized method was successfully applied to the analysis of a lipstick sample where eosine and cyanosine were present.
Decadal oscillations and extreme value distribution of river peak flows in the Meuse catchment
NASA Astrophysics Data System (ADS)
De Niel, Jan; Willems, Patrick
2017-04-01
In flood risk management, flood probabilities are often quantified through Generalized Pareto distributions of river peak flows. One of the main underlying assumptions is that all data points need to originate from one single underlying distribution (i.i.d. assumption). However, this hypothesis, although generally assumed to be correct for variables such as river peak flows, remains somehow questionable: flooding might indeed be caused by different hydrological and/or meteorological conditions. This study confirms these findings from previous research by showing a clear indication of the link between atmospheric conditions and flooding for the Meuse river in The Netherlands: decadal oscillations of river peak flows can (at least partially) be attributed to the occurrence of westerly weather types. The study further proposes a method to take this correlation between atmospheric conditions and river peak flows into account when calibrating an extreme value distribution for river peak flows. Rather than calibrating one single distribution to the data and potentially violating the i.i.d. assumption, weather type depending extreme value distributions are derived and composed. The study shows that, for the Meuse river in The Netherlands, such approach results in a more accurate extreme value distribution, especially with regards to extrapolations. Comparison of the proposed method with a traditional extreme value analysis approach and an alternative model-based approach for the same case study shows strong differences in the peak flow extrapolation. The design-flood for a 1,250 year return period is estimated at 4,800 m3s-1 for the proposed method, compared with 3,450 m3s-1 and 3,900 m3s-1 for the traditional method and a previous study. The methods were validated based on instrumental and documentary flood information of the past 500 years.
NASA Astrophysics Data System (ADS)
Arms, Steven W.; Guzik, David C.; Townsend, Christopher P.
1998-07-01
Critical civil and military structures require 'smart' sensors in order to report their strain histories; this can help to insure safe operation after exposure to potentially damaging loads. A passive resetable peak strain detector was developed by modifying the mechanics of a differential variable reluctance transducer. The peak strain detector was attached to an aluminum test beam along with a bonded resistance strain gauge and a standard DVRT. Strain measurements were recorded during cyclic beam deflections. DVRT output was compared to the bonded resistance strain gauge output, yielding correlation coefficients ranging from 0.9989 to 0.9998 for al teste, including re-attachment of the DVRT to the specimen. Peak bending strains were obtained by the modified peak detect DVRT to the specimen. Peak bending strains were obtained by the modified peak detect DVRT and this was compared to the peak bending strains as measured by the bonded strain gauge. The peak detect DVRT demonstrated an accuracy of approximately +/- 5 percent over a peak range of 2000 to 2800 microstrain.
The Designs of Fins Air-Cooled Cylinders
1939-06-28
4 (a). EMer part of figure 4 clearly shows that, for one pnir of values of s and t, the heat transfer is a maximum. The peak values of the curves of...specified s” curves. Similarly, the peak values of the curves of constant values of t shown in &ure 4 (b) and of similar cwwes plotted for othm values of... picking the values of optimum g and t from these curves: PIots of tk type shown in figure 4 were obtained for - other \\ralues of M and Aplpa,/m by means
Nernst and Seebeck effects in HgTe/CdTe topological insulator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Yuan; Song, Juntao; Li, Yu-Xian, E-mail: yxli@mail.hebtu.edu.cn
2015-03-28
The Seebeck and Nernst effects in HgTe/CdTe quantum wells are studied using the tight-binding Hamiltonian and the nonequilibrium Green's function method. The Seebeck coefficient, S{sub c}, and the Nernst coefficient, N{sub c}, oscillate as a function of E{sub F}, where E{sub F} is the Fermi energy. The Seebeck coefficient shows peaks when the Fermi energy crosses the discrete transverse channels, and the height of the nth peak of the S{sub c} is [ln2/(1/2 +|n|)] for E{sub F} > 0. For the case E{sub F} < 0, the values of the peaks are negative, but the absolute values of the first five peaks are themore » same as those for E{sub F} > 0. The 6th peak of S{sub c} reaches the value [ln2/1.35] due to a higher density of states. When a magnetic field is applied, the Nernst coefficient appears. However, the values of the peaks for N{sub c} are all positive. For a weak magnetic field, the temperature suppresses the oscillation of the Seebeck and Nernst coefficients but increases their magnitude. For a large magnetic field, because of the highly degenerate Landau levels, the peaks of the Seebeck coefficient at position E{sub F}=−12, 10, 28meV, and Nernst coefficient at E{sub F}=−7, 10meV are robust against the temperature.« less
Spotl, C.; Houseknecht, D.W.; Jaques, R.C.
1998-01-01
Dispersed kerogen of the Woodford-Chattanooga and Atoka Formations from the subsurface of the Arkoma Basin show a wide range of thermal maturities (0.38 to 6.1% R(o)) indicating thermal conditions ranging from diagenesis to incipient rock metamorphism. Raman spectral analysis reveals systematic changes of both the first- and second-order spectrum with increasing thermal maturity. These changes include a pronounced increase in the D/O peak height ratio accompanied by a narrowing of the D peak, a gradual decrease in the D/O peak width ratio, and a shift of both peaks toward higher wave numbers. Second-order Raman peaks, though less intensive, also show systematic peak shifting as a function of R(o). These empirical results underscore the high potential of Raman spectrometry as a fast and reliable geothermometer of mature to supermature hydrocarbon source rocks, and as an indicator of thermal maturity levels within the anchizone.Dispersed kerogen of the Woodford-Chattanooga and Atoka Formations from the subsurface of the Arkoma Basin show a wide range of thermal maturities (0.38 to 6.1% Ro) indicating thermal conditions ranging from diagenesis to incipient rock metamorphism. Raman spectral analysis reveals systematic changes of both the first- and second-order spectrum with increasing thermal maturity. These changes include a pronounced increase in the D/O peak height ratio accompanied by a narrowing of the D peak, a gradual decrease in the D/O peak width ratio, and a shift of both peaks toward higher wave numbers. Second-order Raman peaks, though less intensive, also show systematic peak shifting as a function of Ro. These empirical results underscore the high potential of Raman spectrometry as a fast and reliable geothermometer of mature to supermature hydrocarbon source rocks, and as an indicator of thermal maturity levels within the anchizone.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Norton, R.S.; Cossins, A.I.; Kem, W.R.
The solution properties of the polypeptide neurotoxin I from the sea anemone Stichodactyla helianthus (Sh I) have been investigated by high-resolution H nuclear magnetic resonance (NMR) spectroscopy at 300 MHz. The pH dependence of the spectra has been examined over the range 1.1-12.2 at 27{degree}C. Individual pK{sub a} values have been obtained for the {alpha}-ammonium group of Ala-1 (8.6) and the side chains of Glu-8 (3.7), Tyr-36 (10.9), and Tyr-37 (10.8). For the remaining seven carboxyl groups in the molecule, four pK{sub a} values can be clearly identified. The five Lys residues titrate in the range 10.5-11, but individual pK{submore » a} values could not be obtained because of peak overlap. Conformational changes associated with the protonation of carboxylates occur below pH 4, while in the alkaline pH range major unfolding occurs above pH 10. The molecule also unfolds at elevated temperatures. Exchange of the backbone amide protons has been monitored at various values of pH and temperature in the ranges pH 4-5 and 12-27{degree}C. Comparison of these properties of Sh I in solution with those of the related polypeptides anthopleurin A and Anemonia sulcata toxins I and II indicates that Sh I is less stable thermally and that there are some significant differences in the ionic interactions that maintain the tertiary structure. The solvent accessibility of aromatic residues has been probed with photochemically induced dynamic nuclear polarization NMR at 360 MHz.« less
PFReports: A program for systematic checking of annual peaks in NWISWeb
Ryberg, Karen R.
2008-01-01
The accuracy, characterization, and completeness of the U.S. Geological Survey (USGS) peak-flow data drive the determination of flood-frequency estimates that are used daily to design water and transportation infrastructure, delineate flood-plain boundaries, and regulate development and utilization of lands throughout the Nation and are essential to understanding the implications of climate change on flooding. Indeed, this high-profile database reflects and highlights the quality of USGS water-data collection programs. Its extension and improvement are essential to efforts to strengthen USGS networks and science leadership and is worthy of the attention of Water Science Center (WSC) hydrographers. This document describes a computer program, PFReports, and its output that facilitates efficient and robust review and correction of data in the USGS Peak Flow File (PFF) hosted as part of NWISWeb (the USGS public Web interface to much of the data stored and managed within the National Water Information System or NWIS). Checks embedded in the program are recommended as part of a more comprehensive assessment of peak flow data that will eventually include examination of possible regional changes, seasonal changes, and decadal variations in magnitude, timing, and frequency. Just as important as the comprehensive assessment, cleaning up the database will increase the likelihood of improved WSC regional flood-frequency equations. As an example of the value of cleaning up the PFF, data for 26,921 sites in the PFF were obtained. Of those sites, 17,542 sites had peak streamflow values and daily values. For the 17,542 sites, 1,097 peaks were identified that were less than the daily value for the day on which the peak occurred. Of the 26,921 sites, 11,643 had peak streamflow values, concurrent daily values, and at least 10 peaks. At the 11,643 sites, 2,205 peaks were identified as potential outliers in a regression of peak streamflows on daily values. Previous efforts to identify problems with the PFF were time consuming, laborious, and often ineffective. This new suite of checks represents an effort to automate identification of specific problems without plotting or printing large amounts of data that may not have problems. In addition, the results of the checks of the peak flow files are delivered through the World Wide Web with links to individual reports so that WSCs can focus on specific problems in an organized and standardized fashion. Over the years, technical reviews, regional-flood studies, and user inquiries have identified many minor and some major problems in the PFF. However, the cumbersome nature of the PFF editor and a lack of analytical tools have hampered efforts at quality assurance/quality control (QA/QC) and subsequently to make needed revisions to the database. This document is organized to provide information regarding PFReports, especially those tests involving regression and to provide an overview of the review procedures for utilizing the output. It also may be used as a reference for the data qualification codes and abbreviations for the tests. Results of the checks for all peak flow files (March 2008) are available at http://nd.water.usgs.gov/internal/pfreports/.
Acemannan-containing wound dressing gel reduces radiation-induced skin reactions in C3H mice
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roberts, D.B.; Travis, E.L.
To determine (a) whether a wound dressing gel that contains acemannan extracted from aloe leaves affects the severity of radiation-induced acute skin reactions in C3H mice; (b) if so, whether other commercially available gels such as a personal lubricating jelly and a healing ointment have similar effects; and (c) when the wound dressing gel should be applied for maximum effect. Male C3H mice received graded single doses of gamma radiation ranging from 30 to 47.5 Gy to the right leg. In most experiments, the gel was applied daily beginning immediately after irradiation. Dose-response curves were obtained by plotting the percentagemore » of mice that reached or exceeded a given peak skin reaction as a function of dose. Curves were fitted by logit analysis and ED{sub 50} values, and 95% confidence limits were obtained. The average peak skin reactions of the wound dressing gel-treated mice were lower than those of the untreated mice at all radiation doses tested. The ED{sub 50} values for skin reactions of 2.0-2.75 were approximately 7 Gy higher in the wound dressing gel-treated mice. The average peak skin reactions and the ED{sub 50} values for mice treated with personal lubricating jelly or healing ointment were similar to irradiated control values. Reduction in the percentage of mice with skin reactions of 2.5 or more was greatest in the groups that received wound dressing gel for at least 2 weeks beginning immediately after irradiation. There was no effect if gel was applied only before irradiation or beginning 1 week after irradiation. Wound dressing gel, but not personal lubricating jelly or healing ointment, reduces acute radiation-induced skin reactions in C3H mice if applied daily for at least 2 weeks beginning immediately after irradiation. 31 refs., 4 figs., 1 tab.« less
Atmospheric pCO2 Reconstructed across the Early Eocene Hyperthermals
NASA Astrophysics Data System (ADS)
Cui, Y.; Schubert, B.
2015-12-01
Negative carbon isotope excursions (CIEs) are commonly associated with extreme global warming. The Early Eocene is punctuated by five such CIEs, the Paleocene-Eocene thermal maximum (PETM, ca. 55.8 Ma), H1 (ca. 53.6 Ma), H2 (ca. 53.5 Ma), I1 (ca. 53.3 Ma), and I2 (ca. 53.2 Ma), each characterized by global warming. The negative CIEs are recognized in both marine and terrestrial substrates, but the terrestrial substrates exhibit a larger absolute magnitude CIE than the marine substrates. Here we reconcile the difference in CIE magnitude between the terrestrial and marine substrates for each of these events by accounting for the additional carbon isotope fractionation by C3 land plants in response to increased atmospheric pCO2. Our analysis yields background and peak pCO2 values for each of the events. Assuming a common mechanism for each event, we calculate that background pCO2 was not static across the Early Eocene, with the highest background pCO2 immediately prior to I2, the last of the five CIEs. Background pCO2 is dependent on the source used in our analysis with values ranging from 300 to 720 ppmv provided an injection of 13C-depleted carbon with δ13C value of -60‰ (e.g. biogenic methane). The peak pCO2 during each event scales according to the magnitude of CIE, and is therefore greatest during the PETM and smallest during H2. Both background and peak pCO2 are higher if we assume a mechanism of permafrost thawing (δ13C = -25‰). Our reconstruction of pCO2 across these events is consistent with trends in the δ18O value of deep-sea benthic foraminifera, suggesting a strong link between pCO2 and temperature during the Early Eocene.
Zhou, Ruokun; Li, Liang
2015-04-06
The effect of sample injection amount on metabolome analysis in a chemical isotope labeling (CIL) liquid chromatography-mass spectrometry (LC-MS) platform was investigated. The performance of time-of-flight (TOF) mass spectrometers with and without a high-dynamic-range (HD) detection system was compared in the analysis of (12)C2/(13)C2-dansyl labeled human urine samples. An average of 1635 ± 21 (n = 3) peak pairs or putative metabolites was detected using the HD-TOF-MS, compared to 1429 ± 37 peak pairs from a conventional or non-HD TOF-MS. In both instruments, signal saturation was observed. However, in the HD-TOF-MS, signal saturation was mainly caused by the ionization process, while in the non-HD TOF-MS, it was caused by the detection process. To extend the MS detection range in the non-HD TOF-MS, an automated switching from using (12)C to (13)C-natural abundance peaks for peak ratio calculation when the (12)C peaks are saturated has been implemented in IsoMS, a software tool for processing CIL LC-MS data. This work illustrates that injecting an optimal sample amount is important to maximize the metabolome coverage while avoiding the sample carryover problem often associated with over-injection. A TOF mass spectrometer with an enhanced detection dynamic range can also significantly increase the number of peak pairs detected. In chemical isotope labeling (CIL) LC-MS, relative metabolite quantification is done by measuring the peak ratio of a (13)C2-/(12)C2-labeled peak pair for a given metabolite present in two comparative samples. The dynamic range of peak ratio measurement does not need to be very large, as only subtle changes of metabolite concentrations are encountered in most metabolomic studies where relative metabolome quantification of different groups of samples is performed. However, the absolute concentrations of different metabolites can be very different, requiring a technique to provide a wide detection dynamic range to allow the detection of as many peak pairs as possible. In this work, we demonstrated that controlling the sample injection amount into LC-MS was critical to achieve the optimal detectability while avoiding sample carry-over problem. In addition, the use of a high-dynamic-range TOF system increased the number of peak pairs detected, compared to a conventional TOF system. We also investigated the ionization and detection saturation factors limiting the dynamic range of detection. This article is part of a Special Issue entitled: Protein dynamics in health and disease. Guest Editors: Pierre Thibault and Anne-Claude Gingras. Copyright © 2014 Elsevier B.V. All rights reserved.
SU-E-J-149: Secondary Emission Detection for Improved Proton Relative Stopping Power Identification
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saunders, J; Musall, B; Erickson, A
Purpose: This research investigates application of secondary prompt gamma (PG) emission spectra, resulting from nuclear reactions induced by protons, to characterize tissue composition along the particle path. The objective of utilizing the intensity of discrete high-energy peaks of PG is to improve the accuracy of relative stopping power (RSP) values available for proton therapy treatment planning on a patient specific basis and to reduce uncertainty in dose depth calculations. Methods: In this research, MCNP6 was used to simulate PG emission spectra generated from proton induced nuclear reactions in medium of varying composition of carbon, oxygen, calcium and nitrogen, the predominantmore » elements found in human tissue. The relative peak intensities at discrete energies predicted by MCNP6 were compared to the corresponding atomic composition of the medium. Results: The results have shown a good general agreement with experimentally measured values reported by other investigators. Unexpected divergence from experimental spectra was noted in the peak intensities for some cases depending on the source of the cross-section data when using compiled proton table libraries vs. physics models built into MCNP6. While the use of proton cross-section libraries is generally recommended when available, these libraries lack data for several less abundant isotopes. This limits the range of their applicability and forces the simulations to rely on physics models for reactions with natural atomic compositions. Conclusion: Current end-of-range proton imaging provides an average RSP for the total estimated track length. The accurate identification of tissue composition along the incident particle path using PG detection and characterization allows for improved determination of the tissue RSP on the local level. While this would allow for more accurate depth calculations resulting in tighter treatment margins, precise understanding of proton beam behavior in tissue of various compositions is necessary requiring detailed simulations with a high degree of accuracy.« less
NASA Astrophysics Data System (ADS)
Beighley, R. Edward; Moglen, Glenn E.
2003-04-01
A procedure to adjust gauged streamflow data from watersheds urbanized during or after their gauging period is presented. The procedure adjusts streamflow to be representative of a fixed land use condition, which may reflect current or future development conditions. Our intent is to determine what an event resulting in a peak discharge in, for example, 1950 (i.e., before urbanization) would produce on the current urban watershed. While past approaches assumed uniform spatial and temporal changes in urbanization, this study focuses on the use of geographic information systems (GIS) based methodologies for precisely locating in space and time where land use change has occurred. This information is incorporated into a hydrologic model to simulate the change in discharge as a result of changing land use conditions. In this paper, we use historical aerial photographs, GIS linked tax-map data, and recent land use/land cover data to recreate the spatial development history of eight gauged watersheds in the Baltimore-Washington, D. C., metropolitan area. Using our procedure to determine discharge series representative of the current urban watersheds, we found that the increase of the adjusted 2-year discharge ranged from 16 to 70 percent compared with the measured annual maximum discharge series. For the 100-year discharge the adjusted values ranged from 0 to 47 percent greater than the measured values. Additionally, relationships between the increase in flood flows and four measures of urbanization (increase in urban land, decrease in forested land, increase in high-density development, and the spatial development pattern) are investigated for predicting the increase in flood flows for ungauged watersheds. Watersheds with the largest increases in flood flows typically had more extensive development in the areas far removed from the outlet. In contrast, watersheds with development located nearer to the outlet typically had the smallest increases in peak discharge.
NASA Astrophysics Data System (ADS)
Nguyen Duy Doan, Anh; Eracleous, Michael; Runnoe, Jessie; Halpern, Jules P.; Liu, Jia; Mathes, Gavin; Flohic, Helene M. L. G.
2018-01-01
Displaced peaks in the Balmer lines of quasars could serve as indirect evidence for the existence of close, bound supermassive black hole binaries (SBHBs) at sub-parsec separations. In this work, we test the SBHB hypothesis for 14 quasars with double-peaked emission lines using their long-term radial velocity curves. We make use of a Markov Chain Monte Carlo method to explore the parameter space efficiently. Compared to previous works, we have relaxed the assumption of circular orbits, adding two parameters (eccentricity and argument of periapsis) to the parameter space. We also account for jitter, i.e., short-term fluctuations in the radial velocity curves due to processes that are intrinsic to an individual broad-line region. We have found that the distribution of jitter about a smooth radial velocity curve resembles a Gaussian. Thus, jitter is equivalent to increasing measurement uncertainty in individual measurements. The resulting posterior distributions show the lower mass limit of the SBHBs to be in the range of 10^8 - 10^11 solar masses. For several objects, the mass limit drops by a few orders of magnitude compared to previous results by Liu et. al. However, we note that solutions corresponding to minimum masses often require very high orbital eccentricity ( > 0.9). We also calculate the orbital decay timescale of the binaries due to gravitational radiation, finding values in the range 10^6 - 10^11 years; these values correspond to the minimum-mass solutions. For one third of our targets, we can confidently disfavor the SBHB hypothesis on the basis that the minimum mass exceeds even the most massive black holes measured so far (2 x 10^10 solar masses). For the remaining objects, we must take into account the plausibility of a variety of parameters (e.g. eccentricity, lifetime, etc.) in our evaluation.
Kamalzadeh, Zahra; Babanezhad, Esmaeil; Ghaffari, Solmaz; Mohseni Ezhiyeh, Alireza; Mohammadnejad, Mahdieh; Naghibfar, Mehdi; Bararjanian, Morteza; Attar, Hossein
2017-08-01
A new, normal phase high performance liquid chromatography (NP-HPLC) method was developed for separation of Bortezomib (BZB) enantiomers and quantitative determination of (1S,2R)-enantiomer of BZB in active pharmaceutical ingredient (API) samples. The developed method was validated based on International Conference on Harmonisation (ICH) guidelines and it was proved to be accurate, precise and robust. The obtained resolution (RS) between the enantiomers was more than 2. The calibration curve for (1S,2R)-enantiomer was found to be linear in the concentration range of 0.24-5.36 mg/L with regression coefficient (R2) of 0.9998. Additionally, the limit of detection (LOD) and limit of quantification (LOQ) were 0.052 and 0.16 mg/L, respectively. Also, in this study, a precise, sensitive and robust gradient reversed-phase HPLC (RP-HPLC) method was developed and validated for determination of BZB in API samples. The detector response was linear over the concentration range of 0.26-1110.5 mg/L. The values of R2, LOD and LOQ were 0.9999, 0.084 and 0.25 mg/L, respectively. For both NP-HPLC and RP-HPLC methods, all of the RSD (%) values obtained in the precision study were <1.0%. System suitability parameters in terms of tailing factor (TF), number of theoretical plates (N) and RS were TF < 2.0, N > 2,000 and RS > 2.0. The performance of two common integration methods of valley to valley and drop perpendicular for drawing the baseline between two adjacent peaks were investigated for the determination of diastereomeric impurity (Imp-D) in the BZB-API samples. The results showed that the valley to valley method outperform the drop perpendicular method for calculation of Imp-D peak areas. Therefore, valley to valley method was chosen for peak integration. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Hwang, Ui-Jung; Shin, Dongho; Lee, Se Byeong; Lim, Young Kyung; Jeong, Jong Hwi; Kim, Hak Soo; Kim, Ki Hwan
2018-05-01
To apply a scintillating fiber dosimetry system to measure the range of a proton therapy beam, a new method was proposed to correct for the quenching effect on measuring an spread out Bragg peak (SOBP) proton beam whose range is modulated by a range modulator wheel. The scintillating fiber dosimetry system was composed of a plastic scintillating fiber (BCF-12), optical fiber (SH 2001), photo multiplier tube (H7546), and data acquisition system (PXI6221 and SCC68). The proton beam was generated by a cyclotron (Proteus-235) in the National Cancer Center in Korea. It operated in the double-scattering mode and the spread out of the Bragg peak was achieved by a spinning range modulation wheel. Bragg peak beams and SOBP beams of various ranges were measured, corrected, and compared to the ion chamber data. For the Bragg peak beam, quenching equation was used to correct the quenching effect. On the proposed process of correcting SOBP beams, the measured data using a scintillating fiber were separated by the Bragg peaks that the SOBP beam contained, and then recomposed again to reconstruct an SOBP after correcting for each Bragg peak. The measured depth-dose curve for the single Bragg peak beam was well corrected by using a simple quenching equation. Correction for SOBP beam was conducted with a newly proposed method. The corrected SOBP signal was in accordance with the results measured with an ion chamber. We propose a new method to correct for the SOBP beam from the quenching effect in a scintillating fiber dosimetry system. This method can be applied to other scintillator dosimetry for radiation beams in which the quenching effect is shown in the scintillator.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Agarwal, Radhe; Sahoo, Satyaprakash, E-mail: satya504@gmail.com, E-mail: rkatiyar@hpcf.upr.edu; Chitturi, Venkateswara Rao
2015-12-07
Graphitic carbon nanospheres (GCNSs) were prepared by a unique acidic treatment of multi-walled nanotubes. Spherical morphology with a narrow size distribution was confirmed by transmission electron microscopy studies. The room temperature Raman spectra showed a clear signature of D- and G-peaks at around 1350 and 1591 cm{sup −1}, respectively. Temperature dependent Raman scattering measurements were performed to understand the phonon dynamics and first order temperature coefficients related to the D- and G-peaks. The temperature dependent Raman spectra in a range of 83–473 K were analysed, where the D-peak was observed to show a red-shift with increasing temperature. The relative intensity ratio ofmore » D- to G-peaks also showed a significant rise with increasing temperature. Such a temperature dependent behaviour can be attributed to lengthening of the C-C bond due to thermal expansion in material. The estimated value of the thermal conductivity of GCNSs ∼0.97 W m{sup −1} K{sup −1} was calculated using Raman spectroscopy. In addition, the effect of pulsed laser treatment on the GCNSs was demonstrated by analyzing the Raman spectra of post irradiated samples.« less
Lucas-Cuevas, Angel Gabriel; Encarnación-Martínez, Alberto; Camacho-García, Andrés; Llana-Belloch, Salvador; Pérez-Soriano, Pedro
2017-09-01
Tibial accelerations have been associated with a number of running injuries. However, studies attaching the tibial accelerometer on the proximal section are as numerous as those attaching the accelerometer on the distal section. This study aimed to investigate whether accelerometer location influences acceleration parameters commonly reported in running literature. To fulfil this purpose, 30 athletes ran at 2.22, 2.78 and 3.33 m · s -1 with three accelerometers attached with double-sided tape and tightened to the participants' tolerance on the forehead, the proximal section of the tibia and the distal section of the tibia. Time-domain (peak acceleration, shock attenuation) and frequency-domain parameters (peak frequency, peak power, signal magnitude and shock attenuation in both the low and high frequency ranges) were calculated for each of the tibial locations. The distal accelerometer registered greater tibial acceleration peak and shock attenuation compared to the proximal accelerometer. With respect to the frequency-domain analysis, the distal accelerometer provided greater values of all the low-frequency parameters, whereas no difference was observed for the high-frequency parameters. These findings suggest that the location of the tibial accelerometer does influence the acceleration signal parameters, and thus, researchers should carefully consider the location they choose to place the accelerometer so that equivalent comparisons across studies can be made.
Optical spectroscopy of the bladder washout fluid to optimize fluorescence cystoscopy with Hexvix®.
Martoccia, Carla; Zellweger, Matthieu; Lovisa, Blaise; Jichlinski, Patrice; van den Bergh, Hubert; Wagnières, Georges
2014-09-01
Fluorescence cystoscopy enhances detection of early bladder cancer. Water used to inflate thebladder during the procedure rapidly contains urine, which may contain fluorochromes. This frequently degradesfluorescence images. Samples of bladder washout fluid (BWF) or urine were collected (15 subjects). We studiedtheir fluorescence properties and assessed changes induced by pH (4 to 9) and temperature (15°C to 41°C).A typical fluorescence spectrum of BWF features a main peak (excitation/emission: 320∕420 nm, FWHM =50∕100 nm) and a weaker (5% to 20% of main peak intensity), secondary peak (excitation/emission: 455∕525 nm, FWHM = 80∕50 nm). Interpatient fluctuations of fluorescence intensity are observed. Fluorescence intensity decreases when temperature increases (max 30%) or pH values vary (max 25%). Neither approach is compatible with clinical settings. Fluorescence lifetime measurements suggest that 4-pyridoxic acid/riboflavin is the most likely molecule responsible for urine’s main/secondary fluorescence peak. Our measurements give an insight into the spectroscopy of the detrimental background fluorescence. This should be included in the optical design of fluorescence cystoscopes. We estimate that restricting the excitation range from 370–430 nm to 395–415 nm would reduce the BWF background by a factor 2.
Raman scattering in single-crystal sapphire at elevated temperatures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thapa, Juddha; Liu, Bo; Woodruff, Steven D.
Sapphire is a widely used high-temperature material and this work presents thorough characterization of all the measurable Raman scattering modes in sapphire and their temperature dependencies. Here, Raman scattering in bulk sapphire rods is measured from room temperature to 1081 °C and is illustrated as a method of noncontact temperature measurement. A single-line argon ion laser at 488 nm was used to excite the sapphire rods inside a cylindrical furnace. All the anti-Stokes peaks (or lines) were observable through the entire temperature range of interest, while Stokes peaks were observable until they were obscured by background thermal emission. Temperature measurementsmore » were found to be most reliable for A 1g and E g modes using the peaks at ±418, ±379, +578, +645, and, +750 cm -1 (+ and – are designated for Stokes and anti-Stokes peaks respectively). The 418 cm -1 peak was found to be the most intense peak. The temperature dependence of peak position, peak width, and peak area of the ±418 and ±379 peaks is presented. For +578, +645 and +750, the temperature dependence of peak position is presented. The peaks’ spectral positions provide the most precise temperature information within the experimental temperature range. Finally, the resultant temperature calibration curves are given, which indicate that sapphire can be used in high-temperature Raman thermometry with an accuracy of about 1.38°C average standard deviation over the entire >1000°C temperature range.« less
Raman scattering in single-crystal sapphire at elevated temperatures
Thapa, Juddha; Liu, Bo; Woodruff, Steven D.; ...
2017-10-25
Sapphire is a widely used high-temperature material and this work presents thorough characterization of all the measurable Raman scattering modes in sapphire and their temperature dependencies. Here, Raman scattering in bulk sapphire rods is measured from room temperature to 1081 °C and is illustrated as a method of noncontact temperature measurement. A single-line argon ion laser at 488 nm was used to excite the sapphire rods inside a cylindrical furnace. All the anti-Stokes peaks (or lines) were observable through the entire temperature range of interest, while Stokes peaks were observable until they were obscured by background thermal emission. Temperature measurementsmore » were found to be most reliable for A 1g and E g modes using the peaks at ±418, ±379, +578, +645, and, +750 cm -1 (+ and – are designated for Stokes and anti-Stokes peaks respectively). The 418 cm -1 peak was found to be the most intense peak. The temperature dependence of peak position, peak width, and peak area of the ±418 and ±379 peaks is presented. For +578, +645 and +750, the temperature dependence of peak position is presented. The peaks’ spectral positions provide the most precise temperature information within the experimental temperature range. Finally, the resultant temperature calibration curves are given, which indicate that sapphire can be used in high-temperature Raman thermometry with an accuracy of about 1.38°C average standard deviation over the entire >1000°C temperature range.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, N
Purpose: Ocular proton therapy has the following advantages: i) sparing optic nerve, ii) the minimal dose is delivered to surrounding normal tissues. Since the proton therapy center was opened in 2007, 30 patients with ocular tumor have been treated at National Cancer Center using single scattering technique. To develop a solid eye phantom which can verify the output and the beam range with EBT3 film for independent patient QA in ocular proton therapy. Methods: The proton therapy is very effective to treat ocular tumor, because of the Bragg peak feature. In general, the beam shape of eye treatment is aboutmore » 3 cm in diameter and the beam range is under 5 cm. However, proton therapy has uncertainty of beam range problem due to various stopping power of normal tissue, bone, air and so on, so that we should verify the beam range before treatment. For this purpose, a new PMMA phantom with wedge has been developed to use the film dosimetry and the ionization chamber. It is able to place a film on the slope of the phantom, which the spread out Bragg Peak by the water equivalent thickness value of PMMA can be made on the film. We considered to relation with quenching effect of proton energy and range for simple second check. In addition, the ionization chamber (Pin-point chamber, PTW 31014) can be inserted into a hole in the phantom to measure the absolute dose. Results: The output difference and beam range difference were less than 2% and 1.0 mm, respectively, between the measurement and the plan. Conclusion: An eye phantom was developed and its performance was evaluated successfully and it was useful to verify the output. Also with EBT3 film with the quenching effect for measurement depth-dose profile, range to patient QA.« less
Statistical Short-Range Guidance for Peak Wind Speed Forecasts at Edwards Air Force Base, CA
NASA Technical Reports Server (NTRS)
Dreher, Joseph; Crawford, Winifred; Lafosse, Richard; Hoeth, Brian; Burns, Kerry
2008-01-01
The peak winds near the surface are an important forecast element for Space Shuttle landings. As defined in the Shuttle Flight Rules (FRs), there are peak wind thresholds that cannot be exceeded in order to ensure the safety of the shuttle during landing operations. The National Weather Service Spaceflight Meteorology Group (SMG) is responsible for weather forecasts for all shuttle landings. They indicate peak winds are a challenging parameter to forecast. To alleviate the difficulty in making such wind forecasts, the Applied Meteorology Unit (AMTJ) developed a personal computer based graphical user interface (GUI) for displaying peak wind climatology and probabilities of exceeding peak-wind thresholds for the Shuttle Landing Facility (SLF) at Kennedy Space Center. However, the shuttle must land at Edwards Air Force Base (EAFB) in southern California when weather conditions at Kennedy Space Center in Florida are not acceptable, so SMG forecasters requested that a similar tool be developed for EAFB. Marshall Space Flight Center (MSFC) personnel archived and performed quality control of 2-minute average and 10-minute peak wind speeds at each tower adjacent to the main runway at EAFB from 1997- 2004. They calculated wind climatologies and probabilities of average peak wind occurrence based on the average speed. The climatologies were calculated for each tower and month, and were stratified by hour, direction, and direction/hour. For the probabilities of peak wind occurrence, MSFC calculated empirical and modeled probabilities of meeting or exceeding specific 10-minute peak wind speeds using probability density functions. The AMU obtained and reformatted the data into Microsoft Excel PivotTables, which allows users to display different values with point-click-drag techniques. The GUT was then created from the PivotTables using Visual Basic for Applications code. The GUI is run through a macro within Microsoft Excel and allows forecasters to quickly display and interpret peak wind climatology and likelihoods in a fast-paced operational environment. A summary of how the peak wind climatologies and probabilities were created and an overview of the GUT will be presented.
Fukuda, Eriko; Uesawa, Yoshihiro; Baba, Masaki; Suzuki, Ryuichiro; Fukuda, Tatsuo; Shirataki, Yoshiaki; Okada, Yoshihito
2014-11-01
In order to identify the country of growth of Sophora flavescens by chemical fingerprinting, extracts of plants grown in China and Japan were analyzed using direct analysis in real time mass spectrometry (DART)-MS. The peaks characteristic of each country of growth were statistically analyzed using a volcano plot to summarize the relationship between the p-values of a statistical test and the magnitude of the difference in the peak intensities of the samples in the groups. Peaks with ap value < 0.05 in the t-test and a ≥ 2 absolute difference were defined as characteristic. Peaks characteristic of Chinese S. flavescens were found at m/z 439 and 440. In contrast, peaks characteristic of Japanese S. flavescens were found at m/z 313, 423, 437 and 441. The intensity of the selected peaks was similar in Japanese samples, whereas the m/z 439 peak had a significantly higher intensity than the other peaks in Chinese samples. Therefore, differences in selected peak patterns may allow identification of the country of growth of S. flavescens.
Cosmology constraints from shear peak statistics in Dark Energy Survey Science Verification data
Kacprzak, T.; Kirk, D.; Friedrich, O.; ...
2016-08-19
Shear peak statistics has gained a lot of attention recently as a practical alternative to the two point statistics for constraining cosmological parameters. We perform a shear peak statistics analysis of the Dark Energy Survey (DES) Science Verification (SV) data, using weak gravitational lensing measurements from a 139 degmore » $^2$ field. We measure the abundance of peaks identified in aperture mass maps, as a function of their signal-to-noise ratio, in the signal-to-noise range $$0<\\mathcal S / \\mathcal N<4$$. To predict the peak counts as a function of cosmological parameters we use a suite of $N$-body simulations spanning 158 models with varying $$\\Omega_{\\rm m}$$ and $$\\sigma_8$$, fixing $w = -1$, $$\\Omega_{\\rm b} = 0.04$$, $h = 0.7$ and $$n_s=1$$, to which we have applied the DES SV mask and redshift distribution. In our fiducial analysis we measure $$\\sigma_{8}(\\Omega_{\\rm m}/0.3)^{0.6}=0.77 \\pm 0.07$$, after marginalising over the shear multiplicative bias and the error on the mean redshift of the galaxy sample. We introduce models of intrinsic alignments, blending, and source contamination by cluster members. These models indicate that peaks with $$\\mathcal S / \\mathcal N>4$$ would require significant corrections, which is why we do not include them in our analysis. We compare our results to the cosmological constraints from the two point analysis on the SV field and find them to be in good agreement in both the central value and its uncertainty. As a result, we discuss prospects for future peak statistics analysis with upcoming DES data.« less
Vertical Load Induced with Twisted File Adaptive System during Canal Shaping.
Jamleh, Ahmed; Alfouzan, Khalid
2016-12-01
To evaluate the vertical load induced with the Twisted File Adaptive (TFA; SybronEndo, Orange, CA) system during canal shaping of extracted teeth by comparing it with the Twisted File (TF, SybronEndo), ProTaper Next (PTN; Dentsply Maillefer, Ballaigues, Switzerland), and ProTaper Universal (PTU, Dentsply Maillefer) systems. Fifty-two root canals were shaped using the TFA, TF, PTN, or PTU systems (n = 13 for each system). They were shaped gently according to the manufacturers' instructions. During canal shaping, vertical loads were recorded and shown in 2 directions, apically and coronally directed loads. The vertical peak loads of 3 instrumentation stages were used for comparison. The effects of rotary systems on the mean positive and negative peak loads were analyzed statistically using the Kruskal-Wallis and Mann-Whitney tests at a confidence level of 95%. The overall pattern of the instantaneous loads appeared to increase with the use of successive instruments within the system. During canal shaping in all groups, the apically and coronally directed peak loads ranged from 0.84-7.55 N and 2.16-2.79 N, respectively. There were significant differences in both peak loads among the tested systems at each instrumentation stage. TFA had the lowest apically directed peak loads. In terms of coronally directed peak loads, the TFA and TF had a significantly lower amount of loads developed with their instruments than PTN and PTU. The choice of instrument system had an influence on the loads developed during canal shaping. TFA instruments were associated favorably with the lowest values of peak loads followed by TF, PTN, and PTU. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
The, Bertram; Brutty, Mike; Wang, Allan; Campbell, Peter T.; Halliday, Michael J. C.; Ackland, Timothy R.
2014-01-01
Introduction: The objective of this study is to evaluate the biomechanical function of the upper arm after arthroscopic long head of biceps (LHB) tenotomy at long-term follow-up. Materials and Methods: Twenty-five male subjects ranging from 30 to 63 years old were evaluated at a mean follow-up of 7.0 years after tenotomy. Bilateral isokinetic testing was performed to obtain peak torque values, as well as total work done throughout the full range of elbow flexion and supination. Results: Magnetic resonance imaging scans revealed nine unrecognized LHB ruptures in the contralateral arm, leaving 16 subjects to complete the testing protocol. The mean quickDASH score was 8.1 (standard error [SE] 2.5). The mean oxford elbow score was 97.9 (SE 1.6). The tenotomy arm recorded a decrease in peak flexion torque of 7.0% (confidence interval [CI] 1.2-12.8), and a decrease in the peak supination torque of 9.1% (CI 1.8-16.4) relative to the contralateral arm. The total work carried out through the full range of joint motion was reduced in elbow flexion by 5.1% (CI −1.3-11.4) and in forearm supination by 5.7% (CI-2.4-13.9). Discussion: Maximum strength in elbow flexion and forearm supination is significantly reduced compared with the contralateral arm. However, this impairment is partially compensated for by relatively greater strength sustained through the latter stages of joint motion. This results in comparable total work measurements between the tenotomised and contralateral side, potentially accounting for ongoing high levels of patient satisfaction and clinical function in the long term after LHB tenotomy. Level of Evidence IV: Case series without comparison group. PMID:25258498
Surface correlations of hydrodynamic drag for transitionally rough engineering surfaces
NASA Astrophysics Data System (ADS)
Thakkar, Manan; Busse, Angela; Sandham, Neil
2017-02-01
Rough surfaces are usually characterised by a single equivalent sand-grain roughness height scale that typically needs to be determined from laboratory experiments. Recently, this method has been complemented by a direct numerical simulation approach, whereby representative surfaces can be scanned and the roughness effects computed over a range of Reynolds number. This development raises the prospect over the coming years of having enough data for different types of rough surfaces to be able to relate surface characteristics to roughness effects, such as the roughness function that quantifies the downward displacement of the logarithmic law of the wall. In the present contribution, we use simulation data for 17 irregular surfaces at the same friction Reynolds number, for which they are in the transitionally rough regime. All surfaces are scaled to the same physical roughness height. Mean streamwise velocity profiles show a wide range of roughness function values, while the velocity defect profiles show a good collapse. Profile peaks of the turbulent kinetic energy also vary depending on the surface. We then consider which surface properties are important and how new properties can be incorporated into an empirical model, the accuracy of which can then be tested. Optimised models with several roughness parameters are systematically developed for the roughness function and profile peak turbulent kinetic energy. In determining the roughness function, besides the known parameters of solidity (or frontal area ratio) and skewness, it is shown that the streamwise correlation length and the root-mean-square roughness height are also significant. The peak turbulent kinetic energy is determined by the skewness and root-mean-square roughness height, along with the mean forward-facing surface angle and spanwise effective slope. The results suggest feasibility of relating rough-wall flow properties (throughout the range from hydrodynamically smooth to fully rough) to surface parameters.
Temperature driven structural-memory-effects in carbon nanotubes filled with Fe3C nano crystals
NASA Astrophysics Data System (ADS)
Boi, Filippo S.; Zhang, Xiaotian; Corrias, Anna
2018-02-01
We report the observation of novel temperature-driven structural-memory-effects in carbon nanotubes (CNTs) filled with Fe3C nano-crystals. These structural-transitions were measured by means of temperature (T) dependent x-ray diffraction (XRD) in the T-range from 298 K to 12 K. A clear reversible 2θ-shift in the 002-peak of the graphitic-CNTs-walls is found with the decrease of the temperature. As determined by Rietveld refinement, such 2θ-shift translates in a not previously reported decrease in the value of the CNT graphitic c-axis with the decrease of the temperature (from 298 K to 12 K). Also, a clear reversible 2θ-shift in the 031 and 131 diffraction-peaks of Fe3C is observed within the same T-range. Rietveld refinements confirm the existence of such memory-effect and also reveal a gradual decrease of the 010-axis of Fe3C with the decrease of the temperature. These observations imply that the observed structural-memory-effect is a characteristic of CNTs when Fe3C is the encapsulated ferromagnet. The generality of such memory-effects was further confirmed by additional measurements performed on other types of CNTs characterized by continuous Fe3C-filling. XRD measurements in the T-range from 298 K to 673 K revealed also an unusual reversible decrease of the Fe3C-peak intensities with the increase of the temperature. These observations can have important implications on the magnetic data recording applications of these nanostructures by helping in better understanding the unusual temperature-dependent magnetic instabilities of iron-based nano-crystals which have been recently reported in literature.
The, Bertram; Brutty, Mike; Wang, Allan; Campbell, Peter T; Halliday, Michael J C; Ackland, Timothy R
2014-07-01
The objective of this study is to evaluate the biomechanical function of the upper arm after arthroscopic long head of biceps (LHB) tenotomy at long-term follow-up. Twenty-five male subjects ranging from 30 to 63 years old were evaluated at a mean follow-up of 7.0 years after tenotomy. Bilateral isokinetic testing was performed to obtain peak torque values, as well as total work done throughout the full range of elbow flexion and supination. Magnetic resonance imaging scans revealed nine unrecognized LHB ruptures in the contralateral arm, leaving 16 subjects to complete the testing protocol. The mean quickDASH score was 8.1 (standard error [SE] 2.5). The mean oxford elbow score was 97.9 (SE 1.6). The tenotomy arm recorded a decrease in peak flexion torque of 7.0% (confidence interval [CI] 1.2-12.8), and a decrease in the peak supination torque of 9.1% (CI 1.8-16.4) relative to the contralateral arm. The total work carried out through the full range of joint motion was reduced in elbow flexion by 5.1% (CI -1.3-11.4) and in forearm supination by 5.7% (CI-2.4-13.9). Maximum strength in elbow flexion and forearm supination is significantly reduced compared with the contralateral arm. However, this impairment is partially compensated for by relatively greater strength sustained through the latter stages of joint motion. This results in comparable total work measurements between the tenotomised and contralateral side, potentially accounting for ongoing high levels of patient satisfaction and clinical function in the long term after LHB tenotomy. Case series without comparison group.
Over, Thomas M.; Saito, Riki J.; Soong, David T.
2016-06-30
The observed and adjusted values for each streamgage are tabulated. To illustrate the overall effect of the adjustments, differences in the mean, standard deviation, and skewness of the log-transformed observed and urbanization-adjusted peak discharge series by streamgage are computed. For almost every streamgage where an adjustment was applied (no increase in urbanization was reported for a few streamgages), the mean increased and the standard deviation decreased; the effect on skewness values was more variable but usually they increased. Significant positive peak discharge trends were common in the observed values, occurring at 27.3 percent of streamgages at a p-value of 0.05 according to a Kendall’s tau correlation test; in the adjusted values, the incidence of such trends was reduced to 7.0 percent.
Sex Differences During an Overhead Squat Assessment.
Mauntel, Timothy C; Post, Eric G; Padua, Darin A; Bell, David R
2015-08-01
A disparity exists between the rates of male and female lower extremity injuries. One factor that may contribute to this disparity is high-risk biomechanical patterns that are commonly displayed by females. It is unknown what biomechanical differences exist between males and females during an overhead squat. This study compared lower extremity biomechanics during an overhead squat and ranges of motion between males and females. An electromagnetic motion tracking system interfaced with a force platform was used to quantify peak lower extremity kinematics and kinetics during the descent phase of each squat. Range of motion measurements were assessed with a standard goniometer. Differences between male and female kinematics, kinetics, and ranges of motion were identified with t tests. Males displayed greater peak knee valgus angle, peak hip flexion angle, peak vertical ground reaction forces, and peak hip extension moments. Males also displayed less active ankle dorsiflexion with the knee extended and hip internal and external rotation than females. No other differences were observed. The biomechanical differences between males and females during the overhead squat may result from differences in lower extremity ranges of motion. Therefore, sex-specific injury prevention programs should be developed to improve biomechanics and ranges of motion.
Nandanwar, Manish S.; Anderson, Brian J.; Ajayi, Taiwo; Collett, Timothy S.; Zyrianova, Margarita V.
2016-01-01
An evaluation of the gas production potential of Sunlight Peak gas hydrate accumulation in the eastern portion of the National Petroleum Reserve Alaska (NPRA) of Alaska North Slope (ANS) is conducted using numerical simulations, as part of the U.S. Geological Survey (USGS) gas hydrate Life Cycle Assessment program. A field scale reservoir model for Sunlight Peak is developed using Advanced Processes & Thermal Reservoir Simulator (STARS) that approximates the production design and response of this gas hydrate field. The reservoir characterization is based on available structural maps and the seismic-derived hydrate saturation map of the study region. A 3D reservoir model, with heterogeneous distribution of the reservoir properties (such as porosity, permeability and vertical hydrate saturation), is developed by correlating the data from the Mount Elbert well logs. Production simulations showed that the Sunlight Peak prospect has the potential of producing 1.53 × 109 ST m3 of gas in 30 years by depressurization with a peak production rate of around 19.4 × 104 ST m3/day through a single horizontal well. To determine the effect of uncertainty in reservoir properties on the gas production, an uncertainty analysis is carried out. It is observed that for the range of data considered, the overall cumulative production from the Sunlight Peak will always be within the range of ±4.6% error from the overall mean value of 1.43 × 109 ST m3. A sensitivity analysis study showed that the proximity of the reservoir from the base of permafrost and the base of hydrate stability zone (BHSZ) has significant effect on gas production rates. The gas production rates decrease with the increase in the depth of the permafrost and the depth of BHSZ. From the overall analysis of the results it is concluded that Sunlight Peak gas hydrate accumulation behaves differently than other Class III reservoirs (Class III reservoirs are composed of a single layer of hydrate with no underlying zone of mobile fluids) due to its smaller thickness and high angle of dip.
Detection of a stellar flare at extreme ultraviolet wavelengths
NASA Technical Reports Server (NTRS)
Barstow, M. A.; Denby, M.; Pye, J. P.; Pankiewicz, G. S.; Bromage, G. E.; Gonzalez-Riestra, R.
1991-01-01
During the all-sky survey conducted by the Rosat Wide Field Camera, the binary flare star system BY Draconis was monitored with coverage by the IUE satellite far-UV and optical observations and by the Rosat X-ray telescope for part of the time. A stellar flare was detected in all four wavebands. This is the first unambiguous EUV detection of a flare and one of the widest simultaneous wavelength-range coverages obtained. The peak luminosity and total energy of this flare in the photon energy range 0.08-0.18 keV are comparable with the values obtained for a number of flares integrated over a larger energy range by Exosat satellite observations in 1983-86. It is concluded that radiation in the EUV carries away a substantial fraction of the total flare energy.
Amador, Carolina; Chen, Shigao; Manduca, Armando; Greenleaf, James F.; Urban, Matthew W.
2017-01-01
Quantitative ultrasound elastography is increasingly being used in the assessment of chronic liver disease. Many studies have reported ranges of liver shear wave velocities values for healthy individuals and patients with different stages of liver fibrosis. Nonetheless, ongoing efforts exist to stabilize quantitative ultrasound elastography measurements by assessing factors that influence tissue shear wave velocity values, such as food intake, body mass index (BMI), ultrasound scanners, scanning protocols, ultrasound image quality, etc. Time-to-peak (TTP) methods have been routinely used to measure the shear wave velocity. However, there is still a need for methods that can provide robust shear wave velocity estimation in the presence of noisy motion data. The conventional TTP algorithm is limited to searching for the maximum motion in time profiles at different spatial locations. In this study, two modified shear wave speed estimation algorithms are proposed. The first method searches for the maximum motion in both space and time (spatiotemporal peak, STP); the second method applies an amplitude filter (spatiotemporal thresholding, STTH) to select points with motion amplitude higher than a threshold for shear wave group velocity estimation. The two proposed methods (STP and STTH) showed higher precision in shear wave velocity estimates compared to TTP in phantom. Moreover, in a cohort of 14 healthy subjects STP and STTH methods improved both the shear wave velocity measurement precision and the success rate of the measurement compared to conventional TTP. PMID:28092532
Amador Carrascal, Carolina; Chen, Shigao; Manduca, Armando; Greenleaf, James F; Urban, Matthew W
2017-04-01
Quantitative ultrasound elastography is increasingly being used in the assessment of chronic liver disease. Many studies have reported ranges of liver shear wave velocity values for healthy individuals and patients with different stages of liver fibrosis. Nonetheless, ongoing efforts exist to stabilize quantitative ultrasound elastography measurements by assessing factors that influence tissue shear wave velocity values, such as food intake, body mass index, ultrasound scanners, scanning protocols, and ultrasound image quality. Time-to-peak (TTP) methods have been routinely used to measure the shear wave velocity. However, there is still a need for methods that can provide robust shear wave velocity estimation in the presence of noisy motion data. The conventional TTP algorithm is limited to searching for the maximum motion in time profiles at different spatial locations. In this paper, two modified shear wave speed estimation algorithms are proposed. The first method searches for the maximum motion in both space and time [spatiotemporal peak (STP)]; the second method applies an amplitude filter [spatiotemporal thresholding (STTH)] to select points with motion amplitude higher than a threshold for shear wave group velocity estimation. The two proposed methods (STP and STTH) showed higher precision in shear wave velocity estimates compared with TTP in phantom. Moreover, in a cohort of 14 healthy subjects, STP and STTH methods improved both the shear wave velocity measurement precision and the success rate of the measurement compared with conventional TTP.
Methods and equations for estimating peak streamflow per square mile in Virginia’s urban basins
Austin, Samuel H.
2014-01-01
Models are presented that describe Virginia urban area annual peak streamflow per square mile based on basin percent urban area and basin drainage area. Equations are provided to estimate Virginia urban peak flow per square mile of basin drainage area in each of the following annual exceedance probability categories: 0.995, 0.99, 0.95, 0.9, 0.8, 0.67, 0.5, 0.43, 0.2, 0.1, 0.04, 0.02, 0.01, 0.005, and 0.002 (recurrence intervals of 1.005, 1.01, 1.05, 1.11, 1.25, 1.49, 2.0, 2.3, 5, 10, 25, 50, 100, 200, and 500 years, respectively). Equations apply to Virginia drainage basins ranging in size from no less than 1.2 mi2 to no more than 2,400 mi2 containing at least 10 percent urban area, and not more than 96 percent urban area. A total of 115 Virginia drainage basins were analyzed. Actual-by-predicted plots and leverage plots for response variables and explanatory variables in each peak-flow annual exceedance probability category indicate robust model fits and significant explanatory power. Equations for 8 of 15 urban peak-flow response surface models yield R-square values greater than 0.8. Relations identified in statistical models, describing significant increases in urban peak stream discharges as basin urban area increases, affirm empirical relations reported in past studies of change in stream discharge, lag times, and physical streamflow processes, most notably those detailed for urban areas in northern Virginia.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kacprzak, T.; Kirk, D.; Friedrich, O.
Shear peak statistics has gained a lot of attention recently as a practical alternative to the two point statistics for constraining cosmological parameters. We perform a shear peak statistics analysis of the Dark Energy Survey (DES) Science Verification (SV) data, using weak gravitational lensing measurements from a 139 degmore » $^2$ field. We measure the abundance of peaks identified in aperture mass maps, as a function of their signal-to-noise ratio, in the signal-to-noise range $$0<\\mathcal S / \\mathcal N<4$$. To predict the peak counts as a function of cosmological parameters we use a suite of $N$-body simulations spanning 158 models with varying $$\\Omega_{\\rm m}$$ and $$\\sigma_8$$, fixing $w = -1$, $$\\Omega_{\\rm b} = 0.04$$, $h = 0.7$ and $$n_s=1$$, to which we have applied the DES SV mask and redshift distribution. In our fiducial analysis we measure $$\\sigma_{8}(\\Omega_{\\rm m}/0.3)^{0.6}=0.77 \\pm 0.07$$, after marginalising over the shear multiplicative bias and the error on the mean redshift of the galaxy sample. We introduce models of intrinsic alignments, blending, and source contamination by cluster members. These models indicate that peaks with $$\\mathcal S / \\mathcal N>4$$ would require significant corrections, which is why we do not include them in our analysis. We compare our results to the cosmological constraints from the two point analysis on the SV field and find them to be in good agreement in both the central value and its uncertainty. As a result, we discuss prospects for future peak statistics analysis with upcoming DES data.« less
Weissland, Thierry; Faupin, Arnaud; Borel, Benoit; Berthoin, Serge; Leprêtre, Pierre-Marie
2015-01-01
A bioenergetical analysis of manoeuvrability and agility performance for wheelchair players is inexistent. It was aimed at comparing the physiological responses and performance obtained from the octagon multistage field test (MFT) and the modified condition in “8 form” (MFT-8). Sixteen trained wheelchair basketball players performed both tests in randomized condition. The levels performed (end-test score), peak values of oxygen uptake (VO2peak), minute ventilation (VEpeak), heart rate (HRpeak), peak and relative blood lactate (Δ[Lact−] = peak – rest values), and the perceived rating exertion (RPE) were measured. MFT-8 induced higher VO2peak and VEpeak values compared to MFT (VO2peak: 2.5 ± 0.6 versus 2.3 ± 0.6 L·min−1 and VEpeak: 96.3 ± 29.1 versus 86.6 ± 23.4 L·min−1; P < 0.05) with no difference in other parameters. Significant relations between VEpeak and end-test score were correlated for both field tests (P < 0.05). At exhaustion, MFT attained incompletely VO2peak and VEpeak. Among experienced wheelchair players, MFT-8 had no effect on test performance but generates higher physiological responses than MFT. It could be explained by demands of wheelchair skills occurring in 8 form during the modified condition. PMID:25802841
Schwartz, D.P.; Joyner, W.B.; Stein, R.S.; Brown, R.D.; McGarr, A.F.; Hickman, S.H.; Bakun, W.H.
1996-01-01
Summary -- The U.S. Geological Survey was requested by the U.S. Department of the Interior to review the design values and the issue of reservoir-induced seismicity for a concrete gravity dam near the site of the previously-proposed Auburn Dam in the western foothills of the Sierra Nevada, central California. The dam is being planned as a flood-control-only dam with the possibility of conversion to a permanent water-storage facility. As a basis for planning studies the U.S. Army Corps of Engineers is using the same design values approved by the Secretary of the Interior in 1979 for the original Auburn Dam. These values were a maximum displacement of 9 inches on a fault intersecting the dam foundation, a maximum earthquake at the site of magnitude 6.5, a peak horizontal acceleration of 0.64 g, and a peak vertical acceleration of 0.39 g. In light of geological and seismological investigations conducted in the western Sierran foothills since 1979 and advances in the understanding of how earthquakes are caused and how faults behave, we have developed the following conclusions and recommendations: Maximum Displacement. Neither the pre-1979 nor the recent observations of faults in the Sierran foothills precisely define the maximum displacement per event on a fault intersecting the dam foundation. Available field data and our current understanding of surface faulting indicate a range of values for the maximum displacement. This may require the consideration of a design value larger than 9 inches. We recommend reevaluation of the design displacement using current seismic hazard methods that incorporate uncertainty into the estimate of this design value. Maximum Earthquake Magnitude. There are no data to indicate that a significant change is necessary in the use of an M 6.5 maximum earthquake to estimate design ground motions at the dam site. However, there is a basis for estimating a range of maximum magnitudes using recent field information and new statistical fault relations. We recommend reevaluating the maximum earthquake magnitude using current seismic hazard methodology. Design Ground Motions. A large number of strong-motion records have been acquired and significant advances in understanding of ground motion have been achieved since the original evaluations. The design value for peak horizontal acceleration (0.64 g) is larger than the median of one recent study and smaller than the median value of another. The value for peak vertical acceleration (0.39 g) is somewhat smaller than median values of two recent studies. We recommend a reevaluation of the design ground motions that takes into account new ground motion data with particular attention to rock sites at small source distances. Reservoir-Induced Seismicity. The potential for reservoir-induced seismicity must be considered for the Auburn Darn project. A reservoir-induced earthquake is not expected to be larger than the maximum naturally occurring earthquake. However, the probability of an earthquake may be enhanced by reservoir impoundment. A flood-control-only project may involve a lower probability of significant induced seismicity than a multipurpose water-storage dam. There is a need to better understand and quantify the likelihood of this hazard. A methodology should be developed to quantify the potential for reservoir induced seismicity using seismicity data from the Sierran foothills, new worldwide observations of induced and triggered seismicity, and current understanding of the earthquake process. Reevaluation of Design Parameters. The reevaluation of the maximum displacement, maximum magnitude earthquake, and design ground motions can be made using available field observations from the Sierran foothills, updated statistical relations for faulting and ground motions, and current computational seismic hazard methodologies that incorporate uncertainty into the analysis. The reevaluation does not require significant new geological field studies.