  1. Disinfection of wastewater with peracetic acid: a review.

    PubMed

    Kitis, Mehmet

    2004-03-01

    Peracetic acid is a strong disinfectant with a wide spectrum of antimicrobial activity. Due to its bactericidal, virucidal, fungicidal, and sporicidal effectiveness as demonstrated in various industries, the use of peracetic acid as a disinfectant for wastewater effluents has been drawing more attention in recent years. The desirable attributes of peracetic acid for wastewater disinfection are the ease of implementing treatment (without the need for expensive capital investment), broad spectrum of activity even in the presence of heterogeneous organic matter, absence of persistent toxic or mutagenic residuals or by-products, no quenching requirement (i.e., no dechlorination), small dependence on pH, short contact time, and effectiveness for primary and secondary effluents. Major disadvantages associated with peracetic acid disinfection are the increases of organic content in the effluent due to acetic acid (AA) and thus in the potential microbial regrowth (acetic acid is already present in the mixture and is also formed after peracetic acid decomposition). Another drawback to the use of peracetic acid is its high cost, which is partly due to limited production capacity worldwide. However, if the demand for peracetic acid increases, especially from the wastewater industry, the future mass production capacity might also be increased, thus lowering the cost. In such a case, in addition to having environmental advantages, peracetic acid may also become cost-competitive with chlorine.

  2. An Increase in Healthcare-Associated Clostridium difficile Infection Associated with Use of a Defective Peracetic Acid-Based Surface Disinfectant.

    PubMed

    Cadnum, Jennifer L; Jencson, Annette L; O'Donnell, Marguerite C; Flannery, Elizabeth R; Nerandzic, Michelle M; Donskey, Curtis J

    2017-03-01

    BACKGROUND We investigated an increase in the incidence of healthcare-associated Clostridium difficile infection (CDI) that occurred following a change from a bleach disinfectant to a peracetic acid-based disinfectant. OBJECTIVE To evaluate the efficacy of the peracetic acid-based disinfectant. DESIGN Laboratory-based product evaluation. METHODS The commercial peracetic acid-based product is activated on site by mixing a small volume of concentrated hydrogen peroxide and peracetic acid present in a "SmartCap" reservoir with the remaining contents of the container. We measured concentrations of peracetic acid in newly activated and in-use product and determined the stability of nonactivated and activated product. We tested the efficacy of the product against C. difficile spores using the American Society for Testing and Materials standard quantitative carrier disk test method. RESULTS Measured concentrations of peracetic acid (50-800 parts per million [ppm]) were significantly lower than the level stated on the product label (1,500 ppm), and similar results were obtained for containers from multiple lot numbers and from another hospital. Product with peracetic acid levels below 600 ppm had significantly reduced activity against C. difficile spores. Peracetic acid concentrations were reduced markedly after storage of either activated or nonactivated product for several weeks. The Environmental Protection Agency confirmed the finding of low disinfectant levels and ordered discontinuation of sale of the product. CONCLUSION Use of a defective peracetic acid-based surface disinfectant may have contributed to an increase in healthcare-associated CDI. Our findings highlight the importance of evaluating the efficacy of liquid disinfectants in healthcare settings. Infect Control Hosp Epidemiol 2017;38:300-305.

  3. Tolerance of Pseudomonas aeruginosa in in-vitro biofilms to high-level peracetic acid disinfection.

    PubMed

    Akinbobola, A B; Sherry, L; Mckay, W G; Ramage, G; Williams, C

    2017-10-01

    Biofilm has been suggested as a cause of disinfection failures in flexible endoscopes where no lapses in the decontamination procedure can be identified. To test this theory, the activity of peracetic acid, one of the widely used disinfectants in the reprocessing of flexible endoscopes, was evaluated against both planktonic and sessile communities of Pseudomonas aeruginosa. To investigate the ability of P. aeruginosa biofilm to survive high-level peracetic acid disinfection. The susceptibility of planktonic cells of P. aeruginosa and biofilms aged 24, 48, 96, and 192 h to peracetic acid was evaluated by estimating their viability using resazurin viability and plate count methods. The biomass of the P. aeruginosa biofilms was also quantified using Crystal Violet assay. Planktonic cells of P. aeruginosa were treated with 5-30 ppm concentration of peracetic acid in the presence of 3.0 g/L of bovine serum albumin (BSA) for 5 min. Biofilms of P. aeruginosa were also treated with various peracetic acid concentrations (100-3000 ppm) for 5 min. Planktonic cells of P. aeruginosa were eradicated by 20 ppm of peracetic acid, whereas biofilms showed an age-dependent tolerance to peracetic acid, and 96 h biofilm was only eradicated at peracetic acid concentration of 2500 ppm. Ninety-six-hour P. aeruginosa biofilm survives 5 min treatment with 2000 ppm of peracetic acid, which is the working concentration used in some endoscope washer-disinfectors. This implies that disinfection failure of flexible endoscopes might occur when biofilms build up in the lumens of endoscopes. Copyright © 2017. Published by Elsevier Ltd.

  4. Disinfection efficiency of peracetic acid (PAA): inactivation of coliphages and bacterial indicators in a municipal wastewater plant.

    PubMed

    Zanetti, F; De Luca, G; Sacchetti, R; Stampi, S

    2007-11-01

    The aim of the study was to assess the efficiency of low doses of peracetic acid against viral and bacterial indicators in wastewater and to evaluate if the treatment allows regulatory requirements to be satisfied. A total of 31 samplings were carried out, each involving the collection of secondary effluent and of effluent disinfected with 1.2 or 1.5 mg l(-1) of peracetic acid (contact time 20 minutes). In each sample were measured: somatic coliphages, F-specific RNA bacteriophages, Escherichia coli, total and faecal coliforms, enterococci. Peracetic acid disinfection showed significant differences between the reductions of the microorganisms tested: E. coli showed the highest reduction (1.78 and 2.43 Log respectively with 1.2 and 1.5 mg l(-1) of peracetic acid) and phages the lowest (ranging between 0.52 and 0.60 Log). Only a concentration of 1.5 mg l(-1) of peracetic acid would enable the effluent to be discharged into surface waters in compliance with Italian regulations. The variability of microbial resistance against the peracetic acid disinfection treatment, underlines the importance of assessing disinfection efficiency by using more than one indicator microorganism. The detection of E. coli could be usefully accompanied by tests for more resistant microorganisms such as enterococci or coliphages. In conclusion, peracetic acid can be used for the disinfection of effluents even at low doses, with the advantage of reducing costs and preventing the formation of significant amounts of genotoxic by-products.

  5. Efficacy of peracetic acid in rapid disinfection of Resilon and gutta-percha cones compared with sodium hypochlorite, chlorhexidine, and povidone-iodine.

    PubMed

    Subha, N; Prabhakar, V; Koshy, Minu; Abinaya, K; Prabu, M; Thangavelu, Lavanya

    2013-10-01

    The aim of this investigation was to compare the effectiveness of 3% sodium hypochlorite (NaOCl), 2% chlorhexidine, 1% peracetic acid, and 10% povidone-iodine in the rapid disinfection of Resilon (Pentron Clinical Technologies, LLC, Wallingford, CT) and gutta-percha cones contaminated with Enterococcus faecalis and Bacillus subtilis. Two hundred fifty-six samples consisting of 128 gutta-percha cones and 128 Resilon cones were used in this study. The materials were tested for disinfection according to the type of solution (3% NaOCl, 2% chlorhexidine, 1% peracetic acid, or 10% povidone-iodine), the time of exposure to each solution (1 or 5 minutes), and the type of microorganisms (E. faecalis or B. subtilis). Subsequent to the disinfection, samples were placed in test tubes containing 10 mL Mueller-Hinton broth and incubated at 37°C for 7 days. All test tubes were observed at 24-hour intervals and visually checked for turbidity, signifying microbial growth. In this study, 1% peracetic acid showed the best results for both 1 minute and 5 minutes of disinfection, 2% chlorhexidine showed the second best results although it was statistically at par with peracetic acid, and 3% hypochlorite ranked third in disinfection; this was statistically significant when compared with peracetic acid and chlorhexidine. Disinfection by povidone-iodine was the least within all the groups for both contact times although disinfection for 5 minutes showed better results than disinfection for 1 minute for gutta-percha. The outcome of this study confirmed the efficacy of 1% peracetic acid and 2% chlorhexidine in the rapid disinfection of both Resilon and gutta-percha. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  6. Influence of disinfection with peracetic acid and hypochlorite in dimensional alterations of casts obtained from addition silicone and polyether impressions.

    PubMed

    Queiroz, Daher Antonio; Peçanha, Marcelo Massaroni; Neves, Ana Christina Claro; Frizzera, Fausto; Tonetto, Mateus Rodrigues; Silva-Concílio, Laís Regiane

    2013-11-01

    Dental impressions disinfection is important to reduce the risk of cross contamination but this process may produce dimensional distortions. Peracetic acid is a disinfectant agent with several favorable characteristics yet underutilized in Dentistry. The aim of this paper is to compare the dimensional stability of casts obtained from addition silicone and polyether impressions that were immersed for 10 minutes in a solution of 0.2% peracetic acid or 1% sodium hypochlorite. Sixty samples in type IV gypsum were produced after a master cast that simulated a full crown preparation of a maxillary premolar. Samples were divided in 6 groups (n = 10) according to the impression material and disinfection agent: Group AC--addition silicone control (without disinfectant); Group APA--addition silicone + 0.2% peracetic acid; Group AH--addition silicone + 1% sodium hypochlorite; Group PC--polyether control (without disinfectant); Group PPA--polyether + 0.2% peracetic acid; Group PH--polyether + 1% sodium hypochlorite. Cast height, base and top diameter were measured and a mean value was obtained for each sample and group all data was statistically analyzed (ANOVA, p < 0.05). There was not a significant statistical difference between addition silicone and polyether impressions regardless of the disinfectant materials. It can be concluded that disinfection with the proposed agents did not produce significant alterations of the impressions and the peracetic acid could be considered a reliable material to disinfect dental molds.

  7. Disinfection of water in recirculating aquaculture systems with peracetic acid (PAA)

    USDA-ARS?s Scientific Manuscript database

    The disinfection behaviour of peracetic acid (PAA) in recirculating aquaculture systems (RAS) was investigated. Peracetic acid is a strong oxidizing agent found in various concentrations in different products. Three Wofasteril PAA products (E400 (c), Lspecical; AC 150) were tested in vitro for the...

  8. Kinetic model of water disinfection using peracetic acid including synergistic effects.

    PubMed

    Flores, Marina J; Brandi, Rodolfo J; Cassano, Alberto E; Labas, Marisol D

    2016-01-01

    The disinfection efficiencies of a commercial mixture of peracetic acid against Escherichia coli were studied in laboratory scale experiments. The joint and separate action of two disinfectant agents, hydrogen peroxide and peracetic acid, were evaluated in order to observe synergistic effects. A kinetic model for each component of the mixture and for the commercial mixture was proposed. Through simple mathematical equations, the model describes different stages of attack by disinfectants during the inactivation process. Based on the experiments and the kinetic parameters obtained, it could be established that the efficiency of hydrogen peroxide was much lower than that of peracetic acid alone. However, the contribution of hydrogen peroxide was very important in the commercial mixture. It should be noted that this improvement occurred only after peracetic acid had initiated the attack on the cell. This synergistic effect was successfully explained by the proposed scheme and was verified by experimental results. Besides providing a clearer mechanistic understanding of water disinfection, such models may improve our ability to design reactors.

  9. Disinfection of wastewater by hydrogen peroxide or peracetic acid: development of procedures for measurement of residual disinfectant and application to a physicochemically treated municipal effluent.

    PubMed

    Wagner, Monika; Brumelis, Daina; Gehr, Ronald

    2002-01-01

    The Montreal Urban Community Wastewater Treatment Plant (MUCWTP) located in Montreal. Quebec, Canada, uses physicochemical treatment processes prior to discharging wastewater into the St. Lawrence River via an outfall tunnel of 2 hours retention time. Although chlorination facilities exist, they are not being used, and the MUCWTP is seeking alternative methods for disinfection to achieve a 2- to 3-log fecal coliform reduction. Liquid chemical disinfectants were attractive options because of their low capital costs. This led to an investigation of the feasibility of using hydrogen peroxide or peracetic acid. A method for measuring peroxycompounds (hydrogen peroxide or peracetic acid plus hydrogen peroxide) was developed using the peroxidase-based oxidation of 2,2'-azino-bis(3-ethylbenz-thiazoline-6-sulfuric acid) diammonium salt (ABTS) with hydrogen peroxide. The validity of the method was confirmed using effluent from the MUCWTP. Recovery was higher than 90% for peracetic acid levels as low as 1.0 mg/L. Quenching of hydrogen peroxide was achieved with 50-mg/L catalase; quenching of peracetic acid was achieved with 100 mg/L of sodium thiosulfate, followed by 50 mg/L of catalase. Batch disinfection tests were conducted on MUCWTP effluent. Hydrogen peroxide and peracetic acid in wastewater over time could be modeled as a second-order decay, with the decay "constant" being a function of the initial concentration of peroxycompounds. This function was the same for both hydrogen peroxide and peracetic acid, possibly indicating similar decomposition pathways in wastewater matrices. Disinfection was modeled using a modified Hom equation. Required doses of hydrogen peroxide to reach the target fecal coliform levels ranged from 106 to 285 mg/L, with the higher doses occurring when ferric chloride instead of alum was used as the coagulant. Hence, hydrogen peroxide was infeasible as a disinfectant for this application. On the other hand, the peracetic acid dose needed to achieve the target fecal coliform level was only 0.6 to 1.6 mg/L. Therefore, peracetic acid seems to be a promising disinfectant for physicochemical or primary effluent, or combined sewer overflows.

  10. Evaluation of the efficiency of peracetic acid in the disinfection of sewage effluents.

    PubMed

    Stampi, S; De Luca, G; Zanetti, F

    2001-11-01

    Evaluation of the efficiency of peracetic acid in the disinfection of wastewater in a large treatment plant. Over a period of 18 months 30 sample collections were made, each consisting of three samples taken from: raw incoming sewage, secondary effluent (after 10-12 h) and secondary effluent disinfected with 1.5-2 mg l(-1) of peracetic acid (contact time: 20 min). Total coliforms and Escherichia coli declined from 10(7) MPN 100 ml(-1) in the raw sewage to 10(2) in the disinfected effluent and the enterococci fell from 10(6) MPN 100 ml(-1) to 702 MPN 100 ml(-1). The reduction of bacteria increased with the rise in temperature and decreased with the rise in BOD5. Disinfection with peracetic acid reduced levels of faecal contamination by 97%, thus attaining the limit recommended by current Italian law (Escherichia coli

  11. Is peracetic acid suitable for the cleaning step of reprocessing flexible endoscopes?

    PubMed

    Kampf, Günter; Fliss, Patricia M; Martiny, Heike

    2014-09-16

    The bioburden (blood, protein, pathogens and biofilm) on flexible endoscopes after use is often high and its removal is essential to allow effective disinfection, especially in the case of peracetic acid-based disinfectants, which are easily inactivated by organic material. Cleaning processes using conventional cleaners remove a variable but often sufficient amount of the bioburden. Some formulations based on peracetic acid are recommended by manufacturers for the cleaning step. We performed a systematic literature search and reviewed the available evidence to clarify the suitability of peracetic acid-based formulations for cleaning flexible endoscopes. A total of 243 studies were evaluated. No studies have yet demonstrated that peracetic acid-based cleaners are as effective as conventional cleaners. Some peracetic acid-based formulations have demonstrated some biofilm-cleaning effects and no biofilm-fixation potential, while others have a limited cleaning effect and a clear biofilm-fixation potential. All published data demonstrated a limited blood cleaning effect and a substantial blood and nerve tissue fixation potential of peracetic acid. No evidence-based guidelines on reprocessing flexible endoscopes currently recommend using cleaners containing peracetic acid, but some guidelines clearly recommend not using them because of their fixation potential. Evidence from some outbreaks, especially those involving highly multidrug-resistant gram-negative pathogens, indicated that disinfection using peracetic acid may be insufficient if the preceding cleaning step is not performed adequately. Based on this review we conclude that peracetic acid-based formulations should not be used for cleaning flexible endoscopes.

  12. Is peracetic acid suitable for the cleaning step of reprocessing flexible endoscopes?

    PubMed Central

    Kampf, Günter; Fliss, Patricia M; Martiny, Heike

    2014-01-01

    The bioburden (blood, protein, pathogens and biofilm) on flexible endoscopes after use is often high and its removal is essential to allow effective disinfection, especially in the case of peracetic acid-based disinfectants, which are easily inactivated by organic material. Cleaning processes using conventional cleaners remove a variable but often sufficient amount of the bioburden. Some formulations based on peracetic acid are recommended by manufacturers for the cleaning step. We performed a systematic literature search and reviewed the available evidence to clarify the suitability of peracetic acid-based formulations for cleaning flexible endoscopes. A total of 243 studies were evaluated. No studies have yet demonstrated that peracetic acid-based cleaners are as effective as conventional cleaners. Some peracetic acid-based formulations have demonstrated some biofilm-cleaning effects and no biofilm-fixation potential, while others have a limited cleaning effect and a clear biofilm-fixation potential. All published data demonstrated a limited blood cleaning effect and a substantial blood and nerve tissue fixation potential of peracetic acid. No evidence-based guidelines on reprocessing flexible endoscopes currently recommend using cleaners containing peracetic acid, but some guidelines clearly recommend not using them because of their fixation potential. Evidence from some outbreaks, especially those involving highly multidrug-resistant gram-negative pathogens, indicated that disinfection using peracetic acid may be insufficient if the preceding cleaning step is not performed adequately. Based on this review we conclude that peracetic acid-based formulations should not be used for cleaning flexible endoscopes. PMID:25228941

  13. MUTAGENICITY AND DISINFECTION BY-PRODUCTS IN SURFACE DRINKING WATER DISINFECTED WITH PERACETIC ACID

    EPA Science Inventory

    The aims of this research were to study the influence of peracetic acid (PAA) on the formation of mutagens in surface waters used for human consumption and to assess its potential application for the disinfection of drinking water. The results obtained using PAA were compared to ...

  14. Disinfection of water in recirculating aquaculture systems with peracetic acid

    USDA-ARS?s Scientific Manuscript database

    Peracetic acid (PAA) has become a favoured alternative to chlorination in the disinfection of municipal waste water in recent years. It is also commonly used in the food industry as a disinfectant. Based on PAA concentration, the disulfide linkage in enzymes and proteins of microorganisms can be bro...

  15. Influence of a peracetic acid-based immersion on indirect composite resin.

    PubMed

    Samuel, Susana Maria Werner; Fracaro, Gisele Baggio; Collares, Fabrício Mezzomo; Leitune, Vicente Castelo Branco; Campregher, Ulisses Bastos

    2011-06-01

    The aim of this study was to evaluate the influence of immersion in a 0.2% peracetic acid-based disinfectant on the three-point flexural strength, water sorption and water solubility of an indirect composite resin. Specimens were produced according to ISO 4049:2000 specifications and were divided in two groups: Control group, with no disinfection and Disinfected group, with three 10 min immersions in the peracetic acid intercalated with 10 min immersions in sterile distilled water. All evaluations were conducted in compliance with ISO specifications. Three-point flexural strength, water sorption and solubility of indirect composite resin before and after immersion showed no statistical significant differences (p > 0.05) and met ISO standard requirements. Immersion in peracetic acid solution showed no influence in indirect composite resin tested properties.

  16. Introducing a new disinfectant for U.S. aquaculture - peracetic acid

    USDA-ARS?s Scientific Manuscript database

    Peracetic acid (PAA) is a promising disinfectant for biosecurity in the US aquaculture industry to prevent disease outbreaks from fish pathogens. PAA is a stabilized mixture of acetic acid, hydrogen peroxide and water that breaks down quickly to water and vinegar. It is being increasingly used to ...

  17. Evaluation of Combined Peracetic acid and UV treatment for Disinfection of Secondary Wastewater Effluent

    EPA Science Inventory

    The current study evaluates the effectiveness of the combined application of Peracetic acid and ultraviolet radiation as alternative disinfectant agents to the traditional chlorination of wastewater effluents. Various pathogens (E. coli, enterococci and fecal coliforms) were eval...

  18. Peracetic acid: the long road to introduction of this disinfectant into U.S. aquaculture

    USDA-ARS?s Scientific Manuscript database

    Peracetic acid (PAA) is a promising disinfectant for biosecurity in the US aquaculture industry to prevent disease outbreaks from fish pathogens. PAA is a stabilized mixture of acetic acid, hydrogen peroxide and water that breaks down quickly to water and vinegar. It has replaced chlorine in some ...

  19. The introduction of peracetic acid as a new disinfectant for U.S. aquaculture

    USDA-ARS?s Scientific Manuscript database

    Peracetic acid (PAA) is a promising disinfectant for biosecurity in the US aquaculture industry to prevent disease outbreaks from fish pathogens. PAA is a stabilized mixture of acetic acid, hydrogen peroxide and water that breaks down quickly to water and vinegar. It has replaced chlorine in some ...

  20. Use of peracetic acid to disinfect water: toxicity to fish

    USDA-ARS?s Scientific Manuscript database

    There has been strong interest in aquaculture for the use of peracetic acid (PAA) as a disinfectant to prevent freshwater fish pathogens. PAA is a stabilized mixture of acetic acid, hydrogen peroxide and water that does not leave dangerous residues in the environment when it breaks down as most com...

  1. The introduction of peracetic acid as a new disinfectant for U.S. aquaculture

    USDA-ARS?s Scientific Manuscript database

    Peracetic acid (PAA) is a promising disinfectant for biosecurity in the US aquaculture industry to prevent disease outbreaks from fish pathogens. PAA is a stabilized mixture of acetic acid, hydrogen peroxide and water that breaks down quickly to water and vinegar. It is being increasingly used to ...

  2. Antiviral activity of a novel composition of peracetic acid disinfectant on parvoviruses

    PubMed Central

    Dagher, Fadi; Jiang, Jun; Tijssen, Peter; Laliberté, Jean-François

    2017-01-01

    Porcine parvoviruses (PPV) are known to be particularly resistant to many disinfectants used to control other non-enveloped viruses. However, effective disinfectants used against PPV are harsh and corrosive to animal health facilities and the environment. We propose a noncorrosive “green” disinfectant that generates peracetic acid in-situ and is capable of inactivating PPV completely at a 1% concentration for a 10-minute contact time. PMID:28154460

  3. Disinfection with peracetic acid (PAA), an alternative against fish pathogens

    USDA-ARS?s Scientific Manuscript database

    Because of the lack of approved substances to treat fish diseases, disinfecting substances are tested to treat fish pathogens. These agents should not leave dangerous residues in the environment in order to successfully contribute to sustainable aquaculture. One of these substances is peracetic acid...

  4. Sodium hypochlorite-, chlorine dioxide- and peracetic acid-induced genotoxicity detected by the Comet assay and Saccharomyces cerevisiae D7 tests.

    PubMed

    Buschini, Annamaria; Carboni, Pamela; Furlini, Mariangela; Poli, Paola; Rossi, Carlo

    2004-03-01

    Mutagenicity of drinking water is due not only to industrial, agricultural and urban pollution but also to chlorine disinfection by-products. Furthermore, residual disinfection is used to provide a partial safeguard against low level contamination and bacterial re-growth within the distribution system. The aims of this study were to further evaluate the genotoxic potential of the world wide used disinfectants sodium hypochlorite and chlorine dioxide in human leukocytes by the Comet assay and in Saccharomyces cerevisiae strain D7 (mitotic gene conversion, point mutation and mitochondrial DNA mutability, with and without endogenous metabolic activation) and to compare their effects with those of peracetic acid, proposed as an alternative disinfectant. All three disinfectants are weakly genotoxic in human leukocytes (lowest effective dose 0.2 p.p.m. for chlorine dioxide, 0.5 p.p.m. for sodium hypochlorite and peracetic acid). The results in S.cerevisiae show a genotoxic response on the end-points considered with an effect only at doses higher (5- to 10-fold) than the concentration normally used for water disinfection; sodium hypochlorite and peracetic acid are able to induce genotoxic effects without endogenous metabolic activation (in stationary phase cells) whereas chlorine dioxide is effective in growing cells. The Comet assay was more sensitive than the yeast tests, with effective doses in the range normally used for water disinfection processes. The biological effectiveness of the three disinfectants on S.cerevisiae proved to be strictly dependent on cell-specific physiological/biochemical conditions. All the compounds appear to act on the DNA and peracetic acid shows effectiveness similar to sodium hypochlorite and chlorine dioxide.

  5. Growth inhibition of Aeromonas salmonicida and Yersinia ruckeri by disinfectants containing peracetic acid

    USDA-ARS?s Scientific Manuscript database

    Peracetic acid is a therapeutic agent used for disinfection, but it must be investigated in order to mitigate diseases without harmful effects to the fish. These agents should not leave dangerous residues in the environment in order to successfully contribute to sustainable aquaculture. The aim of ...

  6. Growth inhibition of Aeromonas salmonicida and Yersinia ruckeri by disinfectants containing peracetic acid

    USDA-ARS?s Scientific Manuscript database

    Peracetic acid is a therapeutic agent used for disinfection in aquaculture, but it must be investigated thoroughly in order to mitigate diseases without harmful effects to fish. These agents should not leave dangerous residues in the environment in order to successfully contribute to sustainable aq...

  7. Sanitizing with peracetic acid (PAA)- An alternative treatment to use in aquaculture ...?

    USDA-ARS?s Scientific Manuscript database

    Because of the lack of approved treatments for fish disease, disinfectants were tested to treat fish pathogens. One of these substances is peracetic acid (PAA). PAA is an agent used for disinfection in aquaculture, but it must be investigated thoroughly in order to mitigate diseases without harmful ...

  8. Growth inhibition of Aeromonas salmonicida and Yersinia ruckeri by disinfectants containing peracetic acid

    USDA-ARS?s Scientific Manuscript database

    Peracetic acid (PAA) is an agent used for disinfection in aquaculture. PAA contributes to sustainable aquaculture, because it releases no harmful residue in the environment. However, there is lack of guideline about the effective application of different PAA products against various pathogens in p...

  9. Peracetic acid as an alternative disinfection technology for wet weather flows.

    PubMed

    Coyle, Elizabeth E; Ormsbee, Lindell E; Brion, Gail M

    2014-08-01

    Rain-induced wet weather flows (WWFs) consist of combined sewer overflows, sanitary sewer overflows, and stormwater, all of which introduce pathogens to surface waters when discharged. When people come into contact with the contaminated surface water, these pathogens can be transmitted resulting in severe health problems. As such, WWFs should be disinfected. Traditional disinfection technologies are typically cost-prohibitive, can yield toxic byproducts, and space for facilities is often limited, if available. More cost-effective alternative technologies, requiring less space and producing less harmful byproducts are currently being explored. Peracetic acid (PAA) was investigated as one such alternative and this research has confirmed the feasibility and applicability of using PAA as a disinfectant for WWFs. Peracetic acid doses ranging from 5 mg/L to 15 mg/L over contact times of 2 to 10 minutes were shown to be effective and directly applicable to WWF disinfection.

  10. Disinfection efficacy of chlorine and peracetic acid alone or in combination against Aspergillus spp. and Candida albicans in drinking water.

    PubMed

    Sisti, Maurizio; Brandi, Giorgio; De Santi, Mauro; Rinaldi, Laura; Schiavano, Giuditta F

    2012-03-01

    The aim of the present study was to evaluate the fungicidal activity of chlorine and peracetic acid in drinking water against various pathogenic Aspergillus spp. and Candida albicans strains. A. nidulans exhibited the greatest resistance, requiring 10 ppm of chlorine for 30 min contact time for a complete inactivation. Under the same experimental conditions, peracetic acid was even less fungicidal. In this case, A. niger proved to be the most resistant species (50 ppm for 60 min for complete inactivation). All Aspergillus spp. were insensitive to 10 ppm even with extended exposure (>5 h). The combination of chlorine and peracetic acid against Aspergillus spp. did not show synergistic effects except in the case of A. flavus. Complete growth inhibition of C. albicans was observed after about 3 h contact time with 0.2 ppm. C. albicans was less sensitive to peracetic acid. Hence the concentrations of chlorine that are usually present in drinking water distribution systems are ineffective against several Aspergillus spp. and peracetic acid cannot be considered an alternative to chlorine for disinfecting drinking water. The combination of the two biocides is not very effective in eliminating filamentous fungi at the concentrations permitted for drinking water disinfection.

  11. Fish-friendly prophylaxis/disinfection in aquaculture: Low concentration of peracetic acid is stress-free to the carp (Cyprinus carpio) after repeated applications

    USDA-ARS?s Scientific Manuscript database

    Application of peracetic acid (PAA) at low concentrations has been proved to be a broad functional and eco-friendly prophylaxis/disinfection method against various fish pathogens. Therefore, regular applications of low concentration PAA is sufficient to control (potential) pathogens in recirculatin...

  12. Peracetic acid in the disinfection of a hospital water system contaminated with Legionella species.

    PubMed

    Ditommaso, Savina; Biasin, Cinzia; Giacomuzzi, Monica; Zotti, Carla Maria; Cavanna, Alberto; Ruggenini Moiraghi, Angela

    2005-05-01

    To assess the efficacy of an alternative disinfection method for hospital water distribution systems contaminated with Legionella. Disinfection with peracetic acid was performed in a small hospital contaminated with L. pneumophila serotype 1. The disinfectant was used at concentrations of 50 ppm (first three surveillance phases) and 1,000 ppm (fourth surveillance phase) for 30 minutes. Environmental monitoring revealed that disinfection was maintained 1 week after treatment; however, levels of recontamination surpassing baseline values were detected after approximately 1 month. Comparison of water temperatures measured at the distal outlets showed a statistically significant association between temperature and bacterial load. The circulating water temperature was found to be lower in the two wards farthest away from the hot water production plant than in other wards. It was thought that the lower water temperature in the two wards promoted the bacterial growth even after disinfection. Peracetic acid may be useful in emergency situations, but does not provide definitive protection even if used monthly.

  13. Alternative prophylaxis/disinfection in aquaculture - Adaptable stress induced by peracetic acid at low concentration and its application strategy in RAS

    USDA-ARS?s Scientific Manuscript database

    The application of peracetic acid (PAA) at low concentrations has been proven to be a broad-functioning and eco-friendly prophylaxis/disinfection method against various fish pathogens. However, there is lack of knowledge on how to apply PAA in a recirculating aquaculture system (RAS), and whether th...

  14. Study on inactivation kinetics of hepatitis A virus and enteroviruses with peracetic acid and chlorine. New ICC/PCR method to assess disinfection effectiveness.

    PubMed

    Bigliardi, L; Sansebastiano, G

    2006-06-01

    The virucidal activity of chlorine-compounds was studied using hepatitis A virus (HAV) and Poliovirus 2 and comparing the disinfectant efficiency of peracetic acid. HAV presented a higher resistance to HClO than Poliovirus did. With ClO2 the inactivation times of HAV were markedly shorter. A comparison between these data and those resulting from the kinetics with peracetic acid (PA) showed that PA is less effective than chlorine. As a preliminary to future research, the PCR-test integrated with cell-cultures was experimentally introduced for a quick evaluation of the HAV-infectiveness, with the aim of possible application in the field of disinfection and of viruses-isolation from environmental and food samples.

  15. Comparative Transcriptomic and Phenotypic Analysis of the Responses of Bacillus cereus to Various Disinfectant Treatments▿ †

    PubMed Central

    Ceragioli, Mara; Mols, Maarten; Moezelaar, Roy; Ghelardi, Emilia; Senesi, Sonia; Abee, Tjakko

    2010-01-01

    Antimicrobial chemicals are widely applied to clean and disinfect food-contacting surfaces. However, the cellular response of bacteria to various disinfectants is unclear. In this study, the physiological and genome-wide transcriptional responses of Bacillus cereus ATCC 14579 exposed to four different disinfectants (benzalkonium chloride, sodium hypochlorite, hydrogen peroxide, and peracetic acid) were analyzed. For each disinfectant, concentrations leading to the attenuation of growth, growth arrest, and cell death were determined. The transcriptome analysis revealed that B. cereus, upon exposure to the selected concentrations of disinfectants, induced common and specific responses. Notably, the common response included genes involved in the general and oxidative stress responses. Exposure to benzalkonium chloride, a disinfectant known to induce membrane damage, specifically induced genes involved in fatty acid metabolism. Membrane damage induced by benzalkonium chloride was confirmed by fluorescence microscopy, and fatty acid analysis revealed modulation of the fatty acid composition of the cell membrane. Exposure to sodium hypochlorite induced genes involved in metabolism of sulfur and sulfur-containing amino acids, which correlated with the excessive oxidation of sulfhydryl groups observed in sodium hypochlorite-stressed cells. Exposures to hydrogen peroxide and peracetic acid induced highly similar responses, including the upregulation of genes involved in DNA damage repair and SOS response. Notably, hydrogen peroxide- and peracetic acid-treated cells exhibited high mutation rates correlating with the induced SOS response. PMID:20348290

  16. [Are disinfectant residues remained after cleaning hemodialysis machine procedure safe for patients?].

    PubMed

    Szewczyk, Małgorzata; Grzeszczuk, Karolina; Walski, Tomasz; Suder, Marek; Komorowska, Małgorzata

    2013-01-01

    The dialysis machine shall be cleaned and disinfected after each patient treatment or after every 72 hours break in working. An acceptable disinfectants such as Puristeril plus or Puristeril 340, Citrosteril, Diasteril and Sporotal are used for decontamination. Puristeril 340 is designed for cold disinfection and due to the low pH value, the necessary decalcification of hemodialysis machines is easily achieved. It can be used for all haemodialysis systems like hemodialysis machines, water treatment devices and circuit pipes. Diluted Puristeril decomposes in a non-toxic way. Degradation products of peracetic acid, which is main component of Puristeril are: hydrogen peroxide and acetic acid. Peracetic acid is widely used for disinfection due to its exceptionally broad spectrum of microbiocidal activity at low concentrations and short exposure times. After use Puristeril is easily removable by rinsing with water. This paper deals with the effect of the Puristeril toxicity on blood as a function of its concentration and incubation time. Concentration range of 3.5-70 ppm was used, with particular emphasis on concentrations close to 5 ppm, a value is the limit of sensitivity of strips of starch potassium iodide, the tests for detection of peracetic acid. There was a strong increase in autohaemolysis and malondialdehyde concentrations with increasing concentration of Puristeril. There were also changes in dependence on the parameters of the incubation time, with the greatest effects obtained after 2 hours incubation with Puristeril. The detection limit of peracetic acid used strips of starch potassium iodide does not guarantee the safety of a patient undergoing hemodialysis. Even the residual concentration of Puristeril plus cause increased lipid peroxidation of membrane, and therefore suggest the routine use of stripes on the lower limit of detection of peracetic acid or implement measurement of hydrogen peroxide residues performed with sensitivity 1 ppm.

  17. Toxicogenomic response of Mycobacterium bovis BCG to peracetic acid and a comparative analysis of the M. bovis BCG response to three oxidative disinfectants.

    PubMed

    Nde, Chantal W; Toghrol, Freshteh; Jang, Hyeung-Jin; Bentley, William E

    2011-04-01

    Tuberculosis is a leading cause of death worldwide and infects thousands of Americans annually. Mycobacterium bovis causes tuberculosis in humans and several animal species. Peracetic acid is an approved tuberculocide in hospital and domestic environments. This study presents for the first time the transcriptomic changes in M. bovis BCG after treatment with 0.1 mM peracetic acid for 10 and 20 min. This study also presents for the first time a comparison among the transcriptomic responses of M. bovis BCG to three oxidative disinfectants: peracetic acid, sodium hypochlorite, and hydrogen peroxide after 10 min of treatment. Results indicate that arginine biosynthesis, virulence, and oxidative stress response genes were upregulated after both peracetic acid treatment times. Three DNA repair genes were downregulated after 10 and 20 min and cell wall component genes were upregulated after 20 min. The devR-devS signal transduction system was upregulated after 10 min, suggesting a role in the protection against peracetic acid treatment. Results also suggest that peracetic acid and sodium hypochlorite both induce the expression of the ctpF gene which is upregulated in hypoxic environments. Further, this study reveals that in M. bovis BCG, hydrogen peroxide and peracetic acid both induce the expression of katG involved in oxidative stress response and the mbtD and mbtI genes involved in iron regulation/virulence.

  18. Surface detail reproduction and dimensional accuracy of molds: influence of disinfectant solutions and elastomeric impression materials.

    PubMed

    Guiraldo, Ricardo D; Berger, Sandrine B; Siqueira, Ronaldo Mt; Grandi, Victor H; Lopes, Murilo B; Gonini-Júnior, Alcides; Caixeta, Rodrigo V; de Carvalho, Rodrigo V; Sinhoreti, Mário Ac

    2017-04-01

    This study compared the surface detail reproduction and dimensional accuracy of molds after disinfection using 2% sodium hypochlorite, 2% chlorhexidine digluconate or 0.2% peracetic acid to those of molds that were not disinfected, for four elastomeric impression materials: polysulfide (Light Bodied Permlastic), polyether (Impregum Soft), polydimethylsiloxane (Oranwash L) andpolyvinylsiloxane (Aquasil Ultra LV). The molds were prepared on a matrix by applying pressure, using a perforated metal tray. The molds were removed following polymerization and either disinfected (by soaking in one of the solutions for 15 minutes) or not disinfected. The samples were thus divided into 16 groups (n=5). Surface detail reproduction and dimensional accuracy were evaluated using optical microscopy to assess the 20-μm line over its entire 25 mm length. The dimensional accuracy results (%) were subjected to analysis of variance (ANOVA) and the means were compared by Tukey's test (a=5%). The 20-μm line was completely reproduced by all elastomeric impression materials, regardless of disinfection procedure. There was no significant difference between the control group and molds disinfected with peracetic acid for the elastomeric materials Impregum Soft (polyether) and Aquasil Ultra LV (polyvinylsiloxane). The high-level disinfectant peracetic acid would be the choice material for disinfection. Sociedad Argentina de Investigación Odontológica.

  19. Characterization of micro-organisms isolated from dairy industry after cleaning and fogging disinfection with alkyl amine and peracetic acid.

    PubMed

    Bore, E; Langsrud, S

    2005-01-01

    To characterize micro-organisms isolated from Norwegian dairy production plants after cleaning and fogging disinfection with alkyl amine/peracetic acid and to indicate reasons for survival. Microbial samples were collected from five dairy plants after cleaning and fogging disinfection. Isolates from two of these production plants, which used fogging with alkylamino acetate (plant A), and peracetic acid (plant B), were chosen for further characterization. The sequence of the 16S ribosomal DNA, fatty acid analysis and biochemical characteristics were used to identify isolates. Three isolates identified as Rhodococcus erythropolis, Methylobacterium rhodesianum and Rhodotorula mucilaginosa were isolated from plant A and one Sphingomonas sp. and two M. extorquens from plant B. Different patterns of resistance to seven disinfectants in a bactericidal suspension test and variable degree of attachment to stainless steel were found. The strains with higher disinfectant resistance showed lower degree of attachment than susceptible strains. The study identifies and characterizes micro-organisms present after cleaning and fogging disinfection. Both surface attachment and resistance were shown as possible reasons for the presence of the isolates after cleaning and disinfection. These results contribute to the awareness of disinfectant resistance as well as attachment as mechanisms of survival in dairy industry. It also strengthens the argument of frequent alternation of disinfectants in the food processing industry to avoid the establishment of resistant house strains.

  20. Effects of the peracetic acid and sodium hypochlorite on the colour stability and surface roughness of the denture base acrylic resins polymerised by microwave and water bath methods.

    PubMed

    Fernandes, Flavio H C N; Orsi, Iara A; Villabona, Camilo A

    2013-03-01

    This study evaluated the surface roughness (Ra) and color stability of acrylic resin colors (Lucitone 550, QC-20 and Vipi-Wave) used for fabricating bases for complete, removable dentures, overdentures and prosthetic protocol after immersion in chemical disinfectants (1% sodium hypochlorite and 2% peracetic acid) for 30 and 60 minutes. Sixty specimens were made of each commercial brand of resin composite, and divided into 2 groups according to the chemical disinfectants. Specimens had undergone the finishing and polishing procedures, the initial color and roughness measurements were taken (t=0), and after this, ten test specimens of each commercial brand of resin composite were immersed in sodium hypochlorite and ten in peracetic acid, for 30 and 60 minutes, with measurements being taken after each immersion period. These data were submitted to statistical analysis. There was evidence of an increase in Ra after 30 minutes immersion in the disinfectants in all the resins, with QC-20 presenting the highest Ra values, and Vipi-Wave the lowest. After 60 minutes immersion in the disinfectants all the resins presented statistically significant color alteration. Disinfection with 1% sodium hypochlorite and peracetic acid altered the properties of roughness and color of the resins. © 2012 The Gerodontology Society and John Wiley & Sons A/S.

  1. Treatment of Arctic wastewater by chemical coagulation, UV and peracetic acid disinfection.

    PubMed

    Chhetri, Ravi Kumar; Klupsch, Ewa; Andersen, Henrik Rasmus; Jensen, Pernille Erland

    2017-02-16

    Conventional wastewater treatment is challenging in the Arctic region due to the cold climate and scattered population. Thus, no wastewater treatment plant exists in Greenland, and raw wastewater is discharged directly to nearby waterbodies without treatment. We investigated the efficiency of physicochemical wastewater treatment, in Kangerlussuaq, Greenland. Raw wastewater from Kangerlussuaq was treated by chemical coagulation and UV disinfection. By applying 7.5 mg Al/L polyaluminium chloride (PAX XL100), 73% of turbidity and 28% phosphate was removed from raw wastewater. E. coli and Enterococcus were removed by 4 and 2.5 log, respectively, when UV irradiation of 0.70 kWh/m 3 was applied to coagulated wastewater. Furthermore, coagulated raw wastewater in Denmark, which has a chemical quality similar to Greenlandic wastewater, was disinfected by peracetic acid or UV irradiation. Removal of heterotrophic bacteria by applying 6 and 12 mg/L peracetic acid was 2.8 and 3.1 log, respectively. Similarly, removal of heterotrophic bacteria by applying 0.21 and 2.10 kWh/m 3 for UV irradiation was 2.1 and greater than 4 log, respectively. Physicochemical treatment of raw wastewater followed by UV irradiation and/or peracetic acid disinfection showed the potential for treatment of arctic wastewater.

  2. Toxicity on aquatic organisms exposed to secondary effluent disinfected with chlorine, peracetic acid, ozone and UV radiation.

    PubMed

    da Costa, Juliana Berninger; Rodgher, Suzelei; Daniel, Luiz Antonio; Espíndola, Evaldo Luiz Gaeta

    2014-11-01

    The toxic potential of four disinfectant agents (chlorine, ozone, peracetic acid and UV radiation), used in the disinfection of urban wastewater, was evaluated with respect to four aquatic organisms. Disinfection assays were carried out with wastewater from the city of Araraquara (São Paulo State, Brazil), and subsequently, toxicity bioassays were applied in order to verify possible adverse effects to the cladocerans (Ceriodaphnia silvestrii and Daphnia similis), midge larvae Chironomus xanthus and fish (Danio rerio). Under the experimental conditions tested, all the disinfectants were capable of producing harmful effects on the test organisms, except for C. xanthus. The toxicity of the effluent to C. silvestrii was observed to increase significantly as a result of disinfection using 2.5 mg L(-1) chlorine and 29.9 mg L(-1) ozone. Ozonation and chlorination significantly affected the survival of D. similis and D. rerio, causing mortality of 60 to 100 % in comparison to the non-disinfected effluent. In experiments with effluent treated with peracetic acid (PAA) and UV radiation, a statistically significant decrease in survival was only detected for D. rerio. This investigation suggested that the study of the ideal concentrations of disinfectants is a research need for ecologically safe options for the treatment of wastewater.

  3. Surface fixation of dried blood by glutaraldehyde and peracetic acid.

    PubMed

    Kampf, G; Bloss, R; Martiny, H

    2004-06-01

    The difficulties of successful prion inactivation by chemical agents has led to changes in recommendations regarding the reprocessing of instruments including flexible endoscopes. One of the changes is the preference for peracetic acid instead of glutaraldehyde in order to avoid fixation of organic material, but the surface fixation by various active agents has not been fully investigated. We used a standardized amount of dried blood soil on metal carriers (on average 22 mg). One part of the carriers was exposed to different disinfectants (four based on peracetic acid, three based on glutaraldehyde, two based on quaternary ammonium compounds (QAC), one based on QAC and amines, one based on phenols and one cleaning agent) and air dried. The difference compared with the non-exposed soiled carrier was taken as the measure of blood removal by exposure to the disinfectants. In addition the other part of the carriers was exposed to a cleaning agent and air dried. The cleaning agent itself was capable of removing more than 99% of the dried blood and served as a control for non-fixation. The rate of fixation of dried blood was calculated as the ratio of the weight of residual soil on 'soiled, disinfected and cleaned' carriers and on 'soiled and disinfected' carriers. All experiments were repeated eight times. Blood removal varied between 90.3% +/- 1.5% (phenol-based disinfectant) and < 10% (glutaraldehyde-based preparations). Fixation of the remainder was between 76.9 +/- 8.4% and 102.5 +/- 1.1% with glutaraldehyde and between 19.2% +/- 3.3% and 78.1% +/- 2.4% with peracetic acid. No other preparations showed a potential for blood fixation (< 1.3%). Our findings underline the potential for blood fixation, not only by glutaraldehyde, but also by peracetic acid, and support the evidence that effective cleaning should precede the chemical disinfection. Copyright 2004 The Hospital Infection Society

  4. Acute toxicity of peracetic acid to fish

    USDA-ARS?s Scientific Manuscript database

    Peracetic acid (PAA; also called peroxyacetic acid) is a stabilized mixture of acetic acid, hydrogen peroxide and water that does not leave dangerous residues in the environment when it breaks down as most compounds do. PAA is a promising disinfectant in the US aquaculture industry to control paras...

  5. Acute toxicity of peracetic acid to various fish species

    USDA-ARS?s Scientific Manuscript database

    Peracetic acid (PAA; also called peroxyacetic acid) is a promising disinfectant in the US aquaculture industry to control parasites and fungus. It is a stabilized mixture of acetic acid and hydrogen peroxide that does not leave dangerous residues in the environment when it breaks down as most compo...

  6. Preliminary Engineering Report for the Use of Peracetic Acid at the Oak Ridge National Laboratory Sewage Treatment Plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taylor, Paul Allen

    2017-02-01

    The purpose of this report is to identify other disinfection methods to replace the current ozone system and propose a small pilot-scale test. Based on a review of the literature and disinfectants used by other wastewater plants in Tennessee, peracetic acid (PAA) was identified as a leading candidate. This report provides the basis for requesting approval for a pilot-scale study using PAA.

  7. Effects of Peracetic Acid on the Corrosion Resistance of Commercially Pure Titanium (grade 4).

    PubMed

    Raimundo, Lariça B; Orsi, Iara A; Kuri, Sebastião E; Rovere, Carlos Alberto D; Busquim, Thaís P; Borie, Eduardo

    2015-01-01

    The aim of this study was to evaluate the corrosion resistance of pure titanium grade 4 (cp-Ti-4), subjected to disinfection with 0.2% and 2% peracetic acid during different immersion periods using anodic potentiodynamic polarization test in acid and neutral artificial saliva. Cylindrical samples of cp-Ti-4 (5 mm x 5 mm) were used to fabricate 24 working electrodes, which were mechanically polished and divided into eight groups (n=3) for disinfection in 2% and 0.2% peracetic acid for 30 and 120 min. After disinfection, anodic polarization was performed in artificial saliva with pH 4.8 and 6.8 to assess the electrochemical behavior of the electrodes. A conventional electrochemical cell, constituting a reference electrode, a platinum counter electrode, and the working electrode (cp-Ti specimens) were used with a scanning rate of 1 mV/s. Three curves were obtained for each working electrode, and corrosion was characterized by using scanning electron microscopy (SEM) and energy dispersive x-ray spectrometry (EDS). Data of corrosion potential (Ecorr) and passive current (Ipass) obtained by the polarization curves were analyzed statistically by Student's t-test (a=0.05). The statistical analysis showed no significant differences (p>0.05) between artificial saliva types at different concentrations and periods of disinfection, as well as between control and experimental groups. No surface changes were observed in all groups evaluated. In conclusion, disinfection with 0.2% and 2% peracetic acid concentrations did not cause corrosion in samples manufactured with cp-Ti-4.

  8. Could peracetic acid be an alternative treatment in aquaculture?

    USDA-ARS?s Scientific Manuscript database

    Peracetic acid (PAA) is an antimicrobial disinfectant used in agriculture, food processing and medical facilities. It has recently been tested as a means to control infestations of Ichthyophthirius multifiliis and Saprolegnia parasitica. Free-swimming theronts of I. multifiliis can be eliminated u...

  9. Effects of two water disinfectants (chloramine T and peracetic acid) on the epidermis and gills of Garra rufa used in human ichthyotherapy.

    PubMed

    Sirri, R; Zaccaroni, A; Di Biase, A; Mordenti, O; Stancampiano, L; Sarli, G; Mandrioli, L

    2013-01-01

    Doctor fish (Garra rufa) have recently been used for aesthetic purposes and as a medical treatment in patients with psoriasis (ichthyotherapy). For this particular kind of human therapy it is essential to guarantee adequate hygienic conditions for both people and fish. The aim of this study was to test two concentrations of water disinfectants, chloramine T and peracetic acid, on Garra rufa to ascertain possible exposure damage to the epidermis and gills. Fish were exposed to 2 mg/l and 10 mg/l of chloramine T and to 15 microl/l and 45 microl/l of peracetic acid in a 40-minute static bath up to six times a day for one week. The epidermis and gills were checked for histological changes and the number of epidermal mucous cells, club cells and taste buds were quantified; mucous cells were also characterized histochemically to detect alterations in mucin production. No mortality or severe histological changes were found in treated or control fish. Cell count showed a significant increase (p < 0.05) in mucous cells (mean 49.1 +/- 6.7 vs 37.0 +/- 13.1 of controls) in animals treated with peracetic acid independently of the dose. Club cell number showed a significant (p < 0.05) decrease in fish treated with 2 mg/l of chloramine T (mean 74.3 +/- 15.6) and with 45 microl/1 of peracetic acid (mean 78.17 +/- 10.5) compared to controls (mean 107.0 +/- 19.2). Histochemical evaluation of mucous cells did not reveal changes in mucin type in fish exposed to the two disinfectants. The results suggest a good tolerability of Garra rufa to the two disinfectants at the concentrations tested.

  10. Algal toxicity of the alternative disinfectants performic acid (PFA), peracetic acid (PAA), chlorine dioxide (ClO2) and their by-products hydrogen peroxide (H2O2) and chlorite (ClO2-).

    PubMed

    Chhetri, Ravi Kumar; Baun, Anders; Andersen, Henrik Rasmus

    2017-05-01

    Environmental effect evaluation of disinfection of combined sewer overflow events with alternative chemical disinfectants requires that the environmental toxicity of the disinfectants and the main by-products of their use are known. Many disinfectants degrade quickly in water which should be included in the evaluation of both their toxicity as determined in standardized tests and their possible negative effect in the water environment. Here we evaluated according to the standardized ISO 8692 test the toxicity towards the green microalgae, Pseudokirchneriella subcapitata, of three disinfectants: performic acid (PFA), peracetic acid (PAA) and chlorine dioxide (ClO 2 ) as well as two by-products of their use: hydrogen peroxide (H 2 O 2 ) and chlorite. All of the five chemicals investigated showed clear toxicity to the algae with well-defined dose response curves. The EC 50 values ranged from 0.16 to 2.9mg/L based on nominal concentrations leading to the labeling of the chemicals as either toxic or very toxic. The five investigated chemicals decreased in toxicity in the order chlorine dioxide, performic acid, peracetic acid, chlorite and hydrogen peroxide. The stability of the chemicals increased in the same order as the toxicity decrease. This indicates that even though ClO 2 has the highest environmental hazard potential, it may still be suitable as an alternative disinfectant due to its rapid degradation in water. Copyright © 2016 Elsevier GmbH. All rights reserved.

  11. N-nitrosamine formation by monochloramine, free chlorine, and peracetic acid disinfection with presence of amine precursors in drinking water system.

    PubMed

    West, Danielle M; Wu, Qihua; Donovan, Ariel; Shi, Honglan; Ma, Yinfa; Jiang, Hua; Wang, Jianmin

    2016-06-01

    In this study, the formation of eight N-nitrosamines, N-nitrosodimethylamine (NDMA), N-nitrosodiethylamine, N-nitrosomethylamine, N-nitrosodi-n-propylamine, N-nitrosodi-n-butylamine, N-Nitrosopiperidine, N-Nitrosopyrrolidine, N-Nitrosomorpholine, were systematically evaluated with respect to seven N-nitrosamine precursors (dimethylamine, trimethylamine, 3-(dimethylaminomethyl)indole, 4-dimethylaminoantipyrine, ethylmethylamine, diethylamine, dipropylamine) and three disinfectants (monochloramine, free chlorine, peracetic acid) under variable dosages, exposure times, and pH in a drinking water system. Without the presence of the seven selected N-nitrosamine precursors N-nitrosamine formation was not observed under any tested condition except very low levels of N-Nitrosopyrrolidine under some conditions. With selected N-nitrosamine precursors present N-nitrosamines formed at different levels under different conditions. The highest N-nitrosamine formation was NDMA with a maximum concentration of 1180 ng/L by monochloramine disinfection with precursors present; much lower levels of N-nitrosamines were formed by free chlorine disinfection; and no detectable level of N-nitrosamines were observed by peracetic acid disinfection except low level of N-Nitrosodi-n-propylamine under some conditions. NDMA formation was not affected by pH while four other N-nitrosamine formations were slightly affected by sample pH tested between 7 and 9, with formation decreasing with increasing pH. Monochloramine exposure time study displayed fast formation of N-nitrosamines, largely formed in four hours of exposure and maximized after seven days. This was a systematic study on the N-nitrosamine formation with the seven major N-nitrosamine precursors presence and absence under different conditions, including peracetic acid disinfection which has not been studied elsewhere. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Disinfection of septic tank and cesspool wastewater with peracetic acid.

    PubMed

    Heinonen-Tanski, Helvi; Savolainen, Ritva

    2003-08-01

    Wastewaters of private household septic tanks and cesspools have been treated with peracetic acid (1-2 g L(-1)). Adding 1 g L(-1) peracetic acid to wastewaters was easy and has been found to be effective in destroying enteric indicator microorganisms. The careful mixing of peracetic acid and wastewater was found to be important. Winter periods with frozen soil, ice and snow did not constitute extra problems. The bad smell of these wastewaters almost totally disappeared during the treatment. When wastewaters treated with peracetic acid were emptied into animal slurry tanks, hygienization still continued in the mixture of animal slurry and the wastewaters. These wastewaters could thus be released into agricultural soil without risk of microbiological pollution to groundwaters.

  13. Chemical disinfection of combined sewer overflow waters using performic acid or peracetic acids.

    PubMed

    Chhetri, Ravi Kumar; Thornberg, Dines; Berner, Jesper; Gramstad, Robin; Öjstedt, Ulrik; Sharma, Anitha Kumari; Andersen, Henrik Rasmus

    2014-08-15

    We investigated the possibility of applying performic acid (PFA) and peracetic acid (PAA) for disinfection of combined sewer overflow (CSO) in existing CSO management infrastructures. The disinfection power of PFA and PAA towards Escherichia coli (E. coli) and Enterococcus was studied in batch-scale and pre-field experiments. In the batch-scale experiment, 2.5 mg L(-1) PAA removed approximately 4 log unit of E. coli and Enterococcus from CSO with a 360 min contact time. The removal of E. coli and Enterococcus from CSO was always around or above 3 log units using 2-4 mg L(-1) PFA; with a 20 min contact time in both batch-scale and pre-field experiments. There was no toxicological effect measured by Vibrio fischeri when CSO was disinfected with PFA; a slight toxic effect was observed on CSO disinfected with PAA. When the design for PFA based disinfection was applied to CSO collected from an authentic event, the disinfection efficiencies were confirmed and degradation rates were slightly higher than predicted in simulated CSO. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. An EPR study on wastewater disinfection by peracetic acid, hydrogen peroxide and UV irradiation.

    PubMed

    Bianchini, Roberto; Calucci, Lucia; Caretti, Cecilia; Lubello, Claudio; Pinzino, Calogero; Piscicelli, Michela

    2002-09-01

    EPR spectroscopy was applied to obtain qualitative and quantitative information on the radicals produced in disinfection processes of wastewater for agricultural reuse. The DEPMPO spin trap was employed to detect hydroxyl and carbon-centered short living radicals in two different peracetic acid solutions and a hydrogen peroxide solution used for water disinfection either in the absence or in the presence of UV-C irradiation. Moreover, three different kinds of water (wastewater, demineralized water, distilled water) were analysed in order to assess the contribution of Fenton reactions to the radical production. The spectroscopic results were discussed in relation to the efficiency of the different oxidizing agents and UV irradiation in wastewater disinfection evaluated as Escherichia Coli, Faecal and Total Coliforms inactivation.

  15. Comparing peracetic acid and hypochlorite for disinfection of combined sewer overflows: Effects of suspended-solids and pH.

    PubMed

    McFadden, M; Loconsole, J; Schockling, A J; Nerenberg, R; Pavissich, J P

    2017-12-01

    Peracetic acid (PAA) is an alternative disinfectant that may be effective for combined sewer overflow (CSO) disinfection, but little is known about the effect of particle size on PAA disinfection efficiency. In this work, PAA and hypochlorite were compared as disinfectants, with a focus on the effect of wastewater particles. Inactivation experiments were conducted on suspended cultures of Escherichia coli and wastewater suspended solids. Tested size fractions included particle diameters <10μm, <100μm, and raw wastewater. Chlorine disinfection efficiency decreased with increasing solids size. However, solids size had little effect on PAA disinfection. The PAA disinfection efficiency decreased at pH values above 7.5. Live/dead staining revealed that PAA disinfection leaves most cells in a viable but non-culturable condition. Fourier transform infrared spectroscopy (FTIR) analyses suggests that PAA and hypochlorite may inactivate E. coli bacteria by similar mechanisms. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. HIGH-RATE DISINFECTION TECHNIQUES FOR COMBIND SEWER OVERFLOW

    EPA Science Inventory

    This paper presents high-rate disinfection technologies for combined sewer overflow (CSO). The high-rate disinfection technologies of interest are: chlorination/dechlorination, ultraviolet light irradiation (UV), chlorine dioxide (ClO2 ), ozone (O3), peracetic acid (CH3COOOH )...

  17. Surface disinfection challenges for Candida auris: an in-vitro study.

    PubMed

    Kean, R; Sherry, L; Townsend, E; McKloud, E; Short, B; Akinbobola, A; Mackay, W G; Williams, C; Jones, B L; Ramage, G

    2018-04-01

    The emerging pathogenic multidrug-resistant yeast Candida auris is an important source of healthcare-associated infections and of growing global clinical concern. The ability of this organism to survive on surfaces and withstand environmental stressors creates a challenge for eradicating it from hospitals. A panel of C. auris clinical isolates was evaluated on different surface environments against the standard disinfectant sodium hypochlorite and high-level disinfectant peracetic acid. C. auris was shown to selectively tolerate clinically relevant concentrations of sodium hypochlorite and peracetic acid in a surface-dependent manner, which may explain its ability to successfully persist within the hospital environment. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  18. Confirmation that pulse and continuous peracetic acid administration does not disrupt the acute stress response in rainbow trout

    USDA-ARS?s Scientific Manuscript database

    Peracetic acid (PAA) is considered an eco-friendly alternative to other disinfectants of common use in aquaculture. Previous studies showing a reduction of the fish corticosteroid response to PAA administration after repeated exposures suggested that fish can habituate to PAA exposure. Therefore, PA...

  19. A pilot study to assess the effectiveness and cost of routine universal use of peracetic acid sporicidal wipes in a real clinical environment.

    PubMed

    Saha, Avinandan; Botha, Stefan Louis; Weaving, Paul; Satta, Giovanni

    2016-11-01

    Peracetic acid sporicidal wipes have been shown to be an effective disinfectant, but in controlled test environments. Their high cost may restrict use. This pilot study investigated the efficacy and compared the costs of routine universal use of peracetic acid sporicidal wipes versus sporicidal quaternary ammonium compound and alcohol wipes in the disinfection of a hospital environment. The routine universal use of peracetic acid wipes (Clinell Sporicidal; GAMA Healthcare Ltd, London, UK) was allocated to a study ward, whereas the control ward continued with the use of quaternary ammonium compound wipes (Tuffie 5; Vernacare, Bolton, UK) and alcohol wipes (PDI Sani-Cloth 70; PDI, Flint, UK). Twenty high-touch areas in the 2 wards were sampled for the presence of indicator organisms. The weekly detection rates of indicator organisms and weekly healthcare associated infection (HCAI) rates in the 2 wards were compared and examined for decreasing trends over the trial period. The detection rates of indicator organisms and HCAI rates were not significantly different in the 2 wards, and did not decrease significantly over the trial period. However, the peracetic acid wipes seem to be more effective against gram-negative organisms but at a significantly higher cost. Further prospective studies are needed to assess the cost-effectiveness of peracetic acid wipes. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  20. In vitro studies of the antibacterial activity of Copaifera spp. oleoresins, sodium hypochlorite, and peracetic acid against clinical and environmental isolates recovered from a hemodialysis unit.

    PubMed

    Vieira, Rosimara Gonçalves Leite; Moraes, Thaís da Silva; Silva, Larissa de Oliveira; Bianchi, Thamires Chiquini; Veneziani, Rodrigo Cassio Sola; Ambrósio, Sérgio Ricardo; Bastos, Jairo Kenupp; Pires, Regina Helena; Martins, Carlos Henrique Gomes

    2018-01-01

    Patients submitted to hemodialysis therapy are more susceptible to infection, especially to infection by Gram-positive bacteria. Various research works have attempted to discover new antimicrobial agents from plant extracts and other natural products. The present study aimed to assess the antibacterial activities of Copaifera duckei , C. reticulata , and C. oblongifolia oleoresins; sodium hypochlorite; and peracetic acid against clinical and environmental isolates recovered from a Hemodialysis Unit. The Minimum Inhibitory Concentration and the Fractionated Inhibitory Concentration Index were determined; the ability of the tested compounds/extracts to inhibit biofilm formation was evaluated by calculating the MICB 50 and IC 50 . C. duckei was the most efficient among the assayed Copaifera species, and its oleoresin was more effective than peracetic acid and sodium hypochlorite. Copaifera oleoresins and disinfectants did not act synergistically at any of the tested combinations. Certain of C. duckei oleoresin, peracetic acid, and sodium hypochlorite concentrations inhibited biofilm formation and eradicated 50% of the biofilm population. C. duckei oleoresin is a potential candidate for disinfectant formulations. Based on these results and given the high incidence of multi-resistant bacteria in hemodialysis patients, it is imperative that new potential antibacterial agents like C. duckei oleoresin, which is active against Staphylococcus , be included in disinfectant formulations.

  1. High-Rate Disinfection Techniques for Combined Sewer Overflow (Proceedings Paper)

    EPA Science Inventory

    This paper presents high-rate disinfection technologies for combined sewer overflow (CSO). The high-rate disinfection technologies of interest are: chlorination/dechlorination, ultraviolet light irradiation (UV), chlorine dioxide (ClO2 ), ozone (O3), peracetic acid (CH3COOOH ), a...

  2. Peracetic Acid as a Green Disinfectant for Combined Sewer Overflows

    EPA Science Inventory

    This cooperative research and development agreement between U.S. EPA, Solvay, MSDGC, and CB&I is evaluating the potential of PAA for disinfection of Muddy Creek CSO wastewater and comparing that with sodium hypochlorite disinfection. This presentation will document the effectiven...

  3. Periodic bacterial control with peracetic acid in a recirculating aquaculture system and its long-term beneficial effect on fish health

    USDA-ARS?s Scientific Manuscript database

    Peracetic acid (PAA) is being introduced to aquaculture as a sustainable disinfectant. It is suitable for recirculating aquaculture systems (RAS) because of the low effective concentrations and its minimal impact on biofilter function. The application of PAA in a RAS has a combined impact on fish an...

  4. Pulse versus continuous peracetic acid applications: effects on Rainbow trout performance, biofilm formation and water quality

    USDA-ARS?s Scientific Manuscript database

    Peracetic acid (PAA) products are being introduced to aquaculture as sustainable disinfectants. Two strategies are used to apply PAA: short term high dose (1-2 mg L-1 PAA) periodic pulse applications or continuous low dose (< 0.2 mg L-1 PAA) applications. In the present study, these strategies and a...

  5. Comparing Peracetic Acid with Sodium Hypochlorite for Disinfection of Combined Sewer Overflows

    EPA Science Inventory

    This cooperative research and development agreement between U.S. EPA, Solvay, MSDGC, and CB&I is evaluating the potential of PAA for disinfection of Muddy Creek CSO wastewater and comparing that with sodium hypochlorite disinfection. This presentation will document the effective...

  6. Peracetic acid for secondary effluent disinfection: a comprehensive performance assessment.

    PubMed

    Antonelli, M; Turolla, A; Mezzanotte, V; Nurizzo, C

    2013-01-01

    The paper is a review of previous research on secondary effluent disinfection by peracetic acid (PAA) integrated with new data about the effect of a preliminary flash-mixing step. The process was studied at bench and pilot scale to assess its performance for discharge in surface water and agricultural reuse (target microorganisms: Escherichia coli and faecal coliform bacteria). The purposes of the research were: (1) determining PAA decay and disinfection kinetics as a function of operating parameters, (2) evaluating PAA suitability as a disinfectant, (3) assessing long-term disinfection efficiency, (4) investigating disinfected effluent biological toxicity on some aquatic indicator organisms (Vibrio fischeri, Daphnia magna and Selenastrum capricornutum), (5) comparing PAA with conventional disinfectants (sodium hypochlorite, UV irradiation). PAA disinfection was capable of complying with Italian regulations on reuse (10 CFU/100 mL for E. coli) and was competitive with benchmarks. No regrowth phenomena were observed, as long as needed for agricultural reuse (29 h after disinfection), even at negligible concentrations of residual disinfectant. The toxic effect of PAA on the aquatic environment was due to the residual disinfectant in the water, rather than to chemical modification of the effluent.

  7. Inactivation of stable viruses in cell culture facilities by peracetic acid fogging.

    PubMed

    Gregersen, Jens-Peter; Roth, Bernhard

    2012-07-01

    Looking for a robust and simple method to replace formaldehyde fumigation for the disinfection of virus-handling laboratories and facilities, we tested peracetic acid fogging as a method to inactivate stable viruses under practical conditions. Peracetic acid/hydrogen peroxide (5.8%/27.5%, 2.0 mL/m³) was diluted in sufficient water to achieve ≥ 70% relative humidity and was vaporized as <10 μm droplets in a fully equipped 95 m³ laboratory unit. High titers of reovirus 3, MVM parvovirus and an avian polyomavirus were coated on frosted glass carriers and were exposed to the peracetic acid fog in various positions in the laboratory. After vaporization, a 60 min exposure time, and venting of the laboratory, no residual virus was detected on any of the carriers (detection limit <1 infectious unit/sample volume tested). The log reduction values were 9.0 for reovirus, 6.4 for MVM parvovirus, and 7.65 for the polyomavirus. After more than 10 disinfection runs within 12 months, no damage or functional impairment of electrical and electronic equipment was noted. Copyright © 2012 The International Alliance for Biological Standardization. Published by Elsevier Ltd. All rights reserved.

  8. Bench-Scale Evaluation of Peracetic Acid and Twin Oxide ™ as Disinfectants in Drinking Water

    EPA Science Inventory

    Chlorine is widely used as an inexpensive and potent disinfectant in the United States for drinking water. However, chlorine has the potential for forming carcinogenic and mutagenic disinfection by-products (DBPs). In this study, bench scale experiments were conducted at the U.S...

  9. Wastewater disinfection by peracetic acid: assessment of models for tracking residual measurements and inactivation.

    PubMed

    Santoro, Domenico; Gehr, Ronald; Bartrand, Timothy A; Liberti, Lorenzo; Notarnicola, Michele; Dell'Erba, Adele; Falsanisi, Dario; Haas, Charles N

    2007-07-01

    With its potential for low (if any) disinfection byproduct formation and easy retrofit for chlorine contactors, peracetic acid (PAA) or use of PAA in combination with other disinfectant technologies may be an attractive alternative to chlorine-based disinfection. Examples of systems that might benefit from use of PAA are water reuse schemes or plants discharging to sensitive receiving water bodies. Though PAA is in use in numerous wastewater treatment plants in Europe, its chemical kinetics, microbial inactivation rates, and mode of action against microorganisms are not thoroughly understood. This paper presents results from experimental studies of PAA demand, PAA decay, and microbial inactivation, with a complementary modeling analysis. Model results are used to evaluate techniques for measurement of PAA concentration and to develop hypotheses regarding the mode of action of PAA in bacterial inactivation. Kinetic and microbial inactivation rate data were collected for typical wastewaters and may be useful for engineers in evaluating whether to convert from chlorine to PAA disinfection.

  10. Hypochlorous and peracetic acid induced oxidation of dairy proteins.

    PubMed

    Kerkaert, Barbara; Mestdagh, Frédéric; Cucu, Tatiana; Aedo, Philip Roger; Ling, Shen Yan; De Meulenaer, Bruno

    2011-02-09

    Hypochlorous and peracetic acids, both known disinfectants in the food industry, were compared for their oxidative capacity toward dairy proteins. Whey proteins and caseins were oxidized under well controlled conditions at pH 8 as a function of the sanitizing concentration. Different markers for protein oxidation were monitored. The results established that the protein carbonyl content was a rather unspecific marker for protein oxidation, which did not allow one to differentiate the oxidant used especially at the lower concentrations. Cysteine, tryptophan, and methionine were proven to be the most vulnerable amino acids for degradation upon hypochlorous and peracetic acid treatment, while tyrosine was only prone to degradation in the presence of hypochlorous acid. Hypochlorous acid induced oxidation gave rise to protein aggregation, while during peracetic acid induced oxidation, no high molecular weight aggregates were observed. Protein aggregation upon hypochlorous acid oxidation could primarily be linked to tryptophan and tyrosine degradation.

  11. Effect of incubation temperature and pH on the recovery of Bacillus weihenstephanensis spores after exposure to a peracetic acid-based disinfectant or to pulsed light.

    PubMed

    Trunet, C; Mtimet, N; Mathot, A-G; Postollec, F; Leguérinel, I; Couvert, O; Carlin, F; Coroller, L

    2018-04-12

    The recovery at a range of incubation temperatures and pH of spores of Bacillus weihenstephanensis KBAB4 exposed to a peracetic acid-based disinfectant (PABD) or to pulsed light was estimated. Spores of B. weihenstephanensis were produced at 30 °C and pH 7.00, at 30 °C and pH 5.50, or at 12 °C and pH 7.00. The spores were treated with a commercial peracetic acid-based disinfectant at 80 mg·mL -1 for 0 to 200 min at 18 °C or by pulsed light at fluences ranging between 0.4 and 2.3 J·cm -2 for pulsed light treatment. After each treatment, the spores were incubated on nutrient agar at 12 °C, 30 °C or 37 °C, or at pH 5.10, 6.00 or 7.40. Incubation temperature during recovery had a significant impact only near the recovery limits, beyond which surviving spores previously exposed to a PABD or to pulsed light were not able to form colonies. In contrast, a decrease in pH of the recovery nutrient agar had a progressive impact on the ability of spores to form colonies. The time to first log reduction after PABD treatment was 29.5 ± 0.7 min with recovery at pH 7.40, and was tremendously shortened 5.1 ± 0.2 min with recovery at pH 5.10. Concerning the fluence necessary for the first log reduction, it was 1.5 times higher when the spores were recovered at pH 6.00 compared to a recovery at pH 5.10. The impact of recovery temperature and pH can be described with a mathematical model using cardinal temperature and pH as parameters. These effects of temperature and pH on recovery of Bacillus weihenstephanensis spores exposed to a disinfectant combining peracetic acid and hydrogen peroxide, or pulsed light are similar, although these treatments are of different natures. Sporulation temperature or pH did not impact resistance to the peracetic acid-based disinfectant or pulsed light. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Effects of ozone, ultraviolet and peracetic acid disinfection of a primary-treated municipal effluent on the immune system of rainbow trout (Oncorhynchus mykiss).

    PubMed

    Hébert, N; Gagné, F; Cejka, P; Bouchard, B; Hausler, R; Cyr, D G; Blaise, C; Fournier, M

    2008-08-01

    Municipal sewage effluents are complex mixtures that are known to compromise the health condition of aquatic organisms. The aim of this study was to evaluate the impacts of various wastewater disinfection processes on the immune system of juvenile rainbow trout (Oncorhynchus mykiss). The trout were exposed to a primary-treated effluent for 28 days before and after one of each of the following treatments: ultraviolet (UV) radiation, ozonation and peracetic acid. Immune function was characterized in leucocytes from the anterior head kidney by the following three parameters: phagocytosis activity, natural cytotoxic cells (NCC) function and lymphocyte (B and T) proliferation assays. The results show that the fish mass to length ratio was significantly decreased for the primary-treated and all three disinfection processes. Exposure to the primary-treated effluent led to a significant increase in macrophage-related phagocytosis; the addition of a disinfection step was effective in removing this effect. Both unstimulated and mitogen-stimulated T lymphocyte proliferation in fish decreased dramatically in fish exposed to the ozonated effluent compared to fish exposed to either the primary-treated effluent or to aquarium water. Stimulation of T lymphocytes proliferation was observed with the peracetic acid treatment group. In conclusion, the disinfection strategy used can modify the immune system in fish at the level of T lymphocyte proliferation but was effective to remove the effects on phagocytosis activity.

  13. Virucides in apiculture: persistence of surrogate enterovirus under simulated field conditions.

    PubMed

    Prodělalová, Jana; Malenovská, Hana; Moutelíková, Romana; Titěra, Dalibor

    2017-12-01

    Honeybee viruses have been recognized as being among the most important factors leading to colony losses worldwide. Colony food and faeces are regarded as possible sources of infectious viruses able to contaminate the environment and equipment of apiaries. Thus, methods for elimination of viruses are required. No cell culture assay for testing the effect of disinfectants on honeybee viruses is yet available. Therefore, surrogate virus was employed for testing of the efficacy of iodophor- and peracetic acid-based disinfectants in combination with six organic contaminants at +6 °C and +22 °C. Moreover, we evaluated the persistence of the surrogate in honey at +6 °C, +22 °C, and +50 °C. Iodophor-based disinfectant showed a maximum reduction of virus titre of 3.4 log 10 . Peracetic acid reduced the titre (≥4 log 10 ) only at 22 °C and without yeast extract/bovine serum albumin. After 25 days of incubation of the virus - honey mix, no decrease of virus titre was observed at +6 °C, whereas a significant reduction (3.5 log 10 ) was found at +50 °C already after 1 day. Both tested disinfectants can serve as appropriate virucides in apiaries. The effect of peracetic acid significantly depended on temperature and organic contaminants. The iodophor-based disinfectant showed a stable antiviral effect at different temperatures and with different contaminants. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  14. Inactivation of an enterovirus by airborne disinfectants

    PubMed Central

    2013-01-01

    Background The activity of airborne disinfectants on bacteria, fungi and spores has been reported. However, the issue of the virucidal effect of disinfectants spread by fogging has not been studied thoroughly. Methods A procedure has been developed to determine the virucidal activity of peracetic acid-based airborne disinfectants on a resistant non-enveloped virus poliovirus type 1. This virus was laid on a stainless carrier. The products were spread into the room by hot fogging at 55°C for 30 minutes at a concentration of 7.5 mL.m-3. Poliovirus inoculum, supplemented with 5%, heat inactivated non fat dry organic milk, were applied into the middle of the stainless steel disc and were dried under the air flow of a class II biological safety cabinet at room temperature. The Viral preparations were recovered by using flocked swabs and were titered on Vero cells using the classical Spearman-Kärber CPE reading method, the results were expressed as TCID50.ml-1. Results The infectious titer of dried poliovirus inocula was kept at 105 TCID50.mL-1 up to 150 minutes at room temperature. Dried inocula exposed to airborne peracetic acid containing disinfectants were recovered at 60 and 120 minutes post-exposition and suspended in culture medium again. The cytotoxicity of disinfectant containing medium was eliminated through gel filtration columns. A 4 log reduction of infectious titer of dried poliovirus inocula exposed to peracetic-based airborne disinfectant was obtained. Conclusion This study demonstrates that the virucidal activity of airborne disinfectants can be tested on dried poliovirus. PMID:23587047

  15. Adding silver and copper to hydrogen peroxide and peracetic acid in the disinfection of an advanced primary treatment effluent.

    PubMed

    Orta De Velásquez, M T; Yáñez-Noguez, I; Jiménez-Cisneros, B; Luna Pabello, V M

    2008-11-01

    This paper evaluates the efficacy of hydrogen peroxide (HP) and peracetic acid (PAA) in the disinfection of an Advanced Primary Treatment (APT) effluent, and how said disinfection capacities can be enhanced by combining the oxidants with copper (Cu2+) and silver (Ag). The treatment sequence consisted of APT (adding chemicals to water to remove suspended solids by coagulation and flocculation), followed by disinfection with various doses of HP, HP+Cu2+, HP+Ag, PAA and PAA+Ag. Microbiological quality was determined by monitoring concentrations of fecal coliforms (FC), pathogenic bacteria (PB) and helminth eggs (HE) throughout the sequence. The results revealed that APT effluent still contains very high levels of bacteria as the treatment only removes 1-2 log of FC and PB, but the reduction in the number of viable helminth eggs was 83%. Subsequent disinfection stages demonstrated that both HP+Cu2+ and HP+Ag have a marked disinfection capacity for bacteria (3.9 and 3.4 log-inactivation, respectively). Peracetic acid on its own was already extremely efficient at disinfecting for bacteria, and the effect was enhanced when combining PAA with silver (PAA+Ag). The best result for HE removal was achieved by combining PAA with silver (PAA+Ag) at doses of 20 + 2.0 mg l(-1), respectively. The study concluded that the PAA+Ag and HP+Ag combinations were good alternatives for APT effluent disinfection, because the disinfected effluents met the standards in NOM-001-SEMARNAT-1996, Mexico's regulation governing the microbiological quality required in treated wastewater destined for unrestricted reuse in agricultural irrigation (< or =1 helminths per litre). Combining either of these disinfection treatments with a primary method such as APT, therefore, offers an effective and practical way of reducing the health risks normally associated with the reuse of wastewaters.

  16. Evaluation of thirteen haloacetic acids and ten trihalomethanes formation by peracetic acid and chlorine drinking water disinfection.

    PubMed

    Xue, Runmiao; Shi, Honglan; Ma, Yinfa; Yang, John; Hua, Bin; Inniss, Enos C; Adams, Craig D; Eichholz, Todd

    2017-12-01

    Free chlorine is a commonly used disinfectant in drinking water treatment. However, disinfection by-products (DBPs) are formed during water disinfection. Haloacetic acids (HAAs) and trihalomethanes (THMs) are two major groups of DBPs. Iodo-HAAs and iodo-THMs (I-HAAs and I-THMs) are formed during the disinfection of the water containing high levels of iodide and are much more toxic than their chlorinated and brominated analogs. Peracetic acid (PAA) is a strong antimicrobial disinfectant that is expected to reduce the formation of HAAs and THMs during disinfection. In this study, the formations of thirteen HAAs and ten THMs, including the iodinated forms, have been investigated during PAA disinfection and chlorination as the comparison. The DBP formations under different iodide concentrations, pHs, and contact times were systematically investigated. Two types of commercial PAAs containing different concentrations of PAA and hydrogen peroxide (H 2 O 2 ) were studied. A solid-phase microextraction gas chromatography-mass spectrometry method was upgraded for THM analysis including I-THMs. HAAs were analyzed by following a recently developed high performance ion chromatography-tandem mass spectrometry method. Results show that the ratio of PAA and H 2 O 2 concentration significantly affect the formation of I-THMs and I-HAAs. During PAA disinfection with lower PAA than H 2 O 2 , no detectable levels of THMs and HAAs were observed. During PAA disinfection with higher PAA than H 2 O 2 , low levels of monoiodoacetic acid, diiodoacetic acid, and iodoform were formed, and these levels were enhanced with the increase of iodide concentration. No significant quantities of chloro- or bromo-THMs and HAAs were formed during PAA disinfection treatment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Genotoxicity of the disinfection by-products resulting from peracetic acid- or hypochlorite-disinfected sewage wastewater.

    PubMed

    Crebelli, R; Conti, L; Monarca, S; Feretti, D; Zerbini, I; Zani, C; Veschetti, E; Cutilli, D; Ottaviani, M

    2005-03-01

    Wastewater disinfection is routinely carried out to prevent the spread of human pathogens present in wastewater effluents. To this aim, chemical and physical treatments are applied to the effluents before their emission in water bodies. In this study, the influence of two widely used disinfectants, peracetic acid (PAA) and sodium hypochlorite (NaClO), on the formation of mutagenic by-products was investigated. Wastewater samples were collected before and after disinfection, in winter and in summer, at a pilot plant installed in a municipal wastewater-treatment plant. Samples were adsorbed using silica C18 cartridges and the concentrates were tested for mutagenicity in the Salmonella typhimurium reversion test with strains TA98 and TA100. Non-concentrated water samples were tested with two plant genotoxicity assays (the Allium cepa root anaphase aberration test and the Tradescantia/micronucleus test). Mutagenicity assays in bacteria and in Tradescantia showed borderline mutagenicity in some of the wastewater samples, independent of the disinfection procedure applied. Negative results were obtained in the A. cepa anaphase aberration test. These results indicate that, in the conditions applied, wastewater disinfection with PAA and NaClO does not lead to the formation of significant amounts of genotoxic by-products.

  18. Wastewater disinfection alternatives: chlorine, ozone, peracetic acid, and UV light.

    PubMed

    Mezzanotte, V; Antonelli, M; Citterio, S; Nurizzo, C

    2007-11-01

    Disinfection tests were carried out at pilot scale to compare the disinfection efficiency of ozone, sodium hypochlorite (NaOCl), peracetic acid (PAA), and UV irradiation. Total coliforms, fecal coliforms, and Escherichia coli were monitored as reference microorganisms. Total heterotrophic bacteria (THB) were also enumerated by cytometry. At similar doses, NaOCl was more effective than PAA, and its action was less affected by contact time. The results obtained by ozonation were comparable for total coliforms, fecal coliforms, and E. coli. On the contrary, some differences among the three indicators were observed for NaOCl, PAA, and UV. Differences increased with increasing values of the disinfectant concentration times contact time (C x t) and were probably the result of different initial counts, as total coliforms include fecal coliforms, which include E. coli. The UV irradiation lead to complete E. coli removals, even at low doses (10 to 20 mJ/cm2). Total heterotrophic bacteria appeared to be too wide a group to be a good disinfection indicator; no correlation was found among THB inactivation, dose, and contact time.

  19. Assessment of peracetic acid disinfected effluents by microbiotests.

    PubMed

    Antonelli, M; Mezzanotte, V; Panouillères, M

    2009-09-01

    Bioassays were performed by commercially available kits on peracetic acid (PAA) solutions, at different concentrations, and on secondary effluents (from two different wastewater treatment plants) after disinfection at bench-scale, considering both samples containing residual active PAA and the same samples where residual PAA was quenched. Four indicator organisms were used: Vibrio fischeri, Thamnocephalus platyurus, Daphnia magna, and Selenastrum capricornutum. The experiments lead to conclude that Thamnocephalus platyurus is a very sensitive organism, probably not adequate to perform a reliable toxicity assessment of effluents for monitoring purposes. The presence of specific organic compounds deriving from human metabolism and urban pollution, even at very low concentrations, can affect the results of bioassays, especially those performed on Vibrio fischeri. PAA is toxic for bacteria and crustaceans even at concentrations lower than the ones commonly used in wastewater disinfection (2-5 mg/L), while its effect on algae is smaller. The toxic effect on bacteria was expected, as PAA is used for disinfection, but its possible influence on biological processes in the receiving aquatic environment should be considered. Toxicity on crustaceans would confirm the fact that discharging disinfected effluents could raise some environmental problems.

  20. In-Use Evaluation of Peracetic Acid for High-Level Disinfection of Endoscopes.

    PubMed

    Chenjiao, Wu; Hongyan, Zhang; Qing, Gu; Xiaoqi, Zhong; Liying, Gu; Ying, Fang

    2016-01-01

    Many high-level disinfectants have been used for disinfection of endoscopes such as 2% glutaraldehyde (GA), 0.55% ortho-phthalaldehyde (OPA), and peracetic acid (PAA). Both GA and OPA are widely used in disinfection of endoscopes and have been previously discussed, but there is little research on the practical use of PAA as an endoscope disinfectant. An experimental model of a flexible gastrointestinal endoscope being contaminated with 9 strains of microorganism was designed. After the cleaning and disinfecting procedure was completed, we evaluated the biocidal activity (850 ppm PAA, 2% GA, and 0.55% OPA) on our flexible gastrointestinal endoscope model. We also evaluated sterilization effectiveness of PAA on other bacteria, including some antibiotic-resistant bacteria (methicillin-resistant Staphylococcus aureus, vancomycin-resistant Enterococcus, and Clostridium difficile). The residual bacterial colony count number of the PAA-disinfected endoscope was significantly lower than that of the GA- and OPA-disinfected endoscopes. The biocidal effect and efficiency of the endoscope disinfection by PAA appeared to be better than either the GA- or OPA-disinfected endoscope. PAA has demonstrated a good sterilization effect on other bacterial species; of particular note are common antibiotic-resistant bacteria such as methicillin-resistant Staphylococcus aureus, vancomycin-resistant Enterococcus, and Clostridium difficile. The results of this study demonstrate that PAA is a fast and effective high-level disinfectant for use in the reprocessing of flexible endoscopes.

  1. Two-Center Evaluation of Disinfectant Efficacy against Ebola Virus in Clinical and Laboratory Matrices

    PubMed Central

    Smither, Sophie J.; Eastaugh, Lin; Filone, Claire Marie; Freeburger, Denise; Herzog, Artemas; Lever, M. Stephen; Miller, David M.; Mitzel, Dana; Noah, James W.; Reddick-Elick, Mary S.; Reese, Amy; Schuit, Michael; Wlazlowski, Carly B.; Hevey, Michael

    2018-01-01

    Ebola virus (EBOV) in body fluids poses risk for virus transmission. However, there are limited experimental data for such matrices on the disinfectant efficacy against EBOV. We evaluated the effectiveness of disinfectants against EBOV in blood on surfaces. Only 5% peracetic acid consistently reduced EBOV titers in dried blood to the assay limit of quantification. PMID:29261093

  2. Two-Center Evaluation of Disinfectant Efficacy against Ebola Virus in Clinical and Laboratory Matrices.

    PubMed

    Smither, Sophie J; Eastaugh, Lin; Filone, Claire Marie; Freeburger, Denise; Herzog, Artemas; Lever, M Stephen; Miller, David M; Mitzel, Dana; Noah, James W; Reddick-Elick, Mary S; Reese, Amy; Schuit, Michael; Wlazlowski, Carly B; Hevey, Michael; Wahl-Jensen, Victoria

    2018-01-01

    Ebola virus (EBOV) in body fluids poses risk for virus transmission. However, there are limited experimental data for such matrices on the disinfectant efficacy against EBOV. We evaluated the effectiveness of disinfectants against EBOV in blood on surfaces. Only 5% peracetic acid consistently reduced EBOV titers in dried blood to the assay limit of quantification.

  3. Effectiveness of disinfectant treatments for inactivating Piscirickettsia salmonis.

    PubMed

    Muniesa, A; Escobar-Dodero, J; Silva, N; Henríquez, P; Bustos, P; Perez, A M; Mardones, F O

    2018-03-08

    This short communication investigated in vitro differences between commercial disinfectants types (n = 36), doses of application, and time of action in the elimination of Piscirickettsia salmonis, the most important bacterium affecting farmed salmon in Chile. Seven different treatments were examined, including active and inactive chlorine dioxides, glutaraldehyde, hypochlorite disinfectants and detergents, peracetic acid, peroxides and other miscellaneous methods A 3 replicate set of each of the sample groups was stored at 20 °C and 95% relative humidity and retested after 1, 5 and 30 min with varying doses (low, recommended and high doses). Multiple comparison tests were performed for the mean log CFU/ml among different disinfectant types, dose (ppm) and time of exposure (minutes) on the reduction of P. salmonis. Overall, disinfection using peracetic acid, peroxides, and both active and inactive chlorine dioxides caused significantly higher reduction of >7.5 log CFU/ml in samples, compared to other tested sanitizers. The lowest reduction was obtained after disinfection with hypochlorite detergents. As expected, as doses and time of action increase, there was a significant reduction of the overall counts of P. salmonis. However, at lowest doses, only use of paracetic acids resulted in zero counts. Implementation of effective protocols, making use of adequate disinfectants, may enhance biosecurity, and ultimately, mitigate the impact of P. salmonis in farmed salmon. Copyright © 2018. Published by Elsevier B.V.

  4. Methodology for modeling the disinfection efficiency of fresh-cut leafy vegetables wash water applied on peracetic acid combined with lactic acid.

    PubMed

    Van Haute, S; López-Gálvez, F; Gómez-López, V M; Eriksson, Markus; Devlieghere, F; Allende, Ana; Sampers, I

    2015-09-02

    A methodology to i) assess the feasibility of water disinfection in fresh-cut leafy greens wash water and ii) to compare the disinfectant efficiency of water disinfectants was defined and applied for a combination of peracetic acid (PAA) and lactic acid (LA) and comparison with free chlorine was made. Standardized process water, a watery suspension of iceberg lettuce, was used for the experiments. First, the combination of PAA+LA was evaluated for water recycling. In this case disinfectant was added to standardized process water inoculated with Escherichia coli (E. coli) O157 (6logCFU/mL). Regression models were constructed based on the batch inactivation data and validated in industrial process water obtained from fresh-cut leafy green processing plants. The UV254(F) was the best indicator for PAA decay and as such for the E. coli O157 inactivation with PAA+LA. The disinfection efficiency of PAA+LA increased with decreasing pH. Furthermore, PAA+LA efficacy was assessed as a process water disinfectant to be used within the washing tank, using a dynamic washing process with continuous influx of E. coli O157 and organic matter in the washing tank. The process water contamination in the dynamic process was adequately estimated by the developed model that assumed that knowledge of the disinfectant residual was sufficient to estimate the microbial contamination, regardless the physicochemical load. Based on the obtained results, PAA+LA seems to be better suited than chlorine for disinfecting process wash water with a high organic load but a higher disinfectant residual is necessary due to the slower E. coli O157 inactivation kinetics when compared to chlorine. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Effectiveness of 2% peracetic acid for the disinfection of gutta-percha cones.

    PubMed

    Salvia, Ana Carolina Rodrigues Danzi; Teodoro, Guilherme Rodrigues; Balducci, Ivan; Koga-Ito, Cristiane Yumi; Oliveira, Simone Helena Gonçalves de

    2011-01-01

    The aim of this study was to evaluate the effectiveness of 2% peracetic acid for the disinfection of gutta-percha cones contaminated in vitro with Escherichia coli, Staphylococcus aureus, Streptococcus mutans, Candida albicans and Bacillus subtilus (in spore form). Two hundred and twenty-five gutta-percha cones were contaminated with standardized suspensions of each microorganism and incubated at 37°C for 24 h. The cones were divided into 10 experimental groups (n = 15), according to the microorganism tested and disinfection testing times. The disinfection procedure consisted of immersing each cone in a plastic tube containing the substance. The specimens remained in contact with the substance for 1 or 2.5 minutes. Afterwards, each cone was transferred to a 10% sodium thiosulphate solution (Na(2)S(2)O(3)) to neutralize the disinfectant. Microbial biofilms adhering to the cones were dispersed by agitation. Aliquots of 0.1 ml of the suspensions obtained were plated on Sabouraud dextrose agar, or brain and heart infusion agar, and incubated at 37°C for 24 h. The results were expressed in colony forming units (CFU/ml) and the data were submitted to the Wilcoxon Signed Rank Test (level of significance at 0.05). A significant reduction was observed, after 1 minute of exposure, in the test solution for C. albicans (p = 0.0190), S. aureus (p = 0.0001), S. mutans (p = 0.0001), B. subtilis (p = 0.0001), and E. coli (p = 0.0001). After 2.5 minutes of exposure, 100% of the microbial inocula were eliminated. It was concluded that the 2% peracetic acid solution was effective against the biofilms of the tested microorganisms on gutta-percha cones at 1 minute of exposure.

  6. Comparative study on the efficiency of peracetic acid and chlorine dioxide at low doses in the disinfection of urban wastewaters.

    PubMed

    De Luca, Giovanna; Sacchetti, Rossella; Zanetti, Franca; Leoni, Erica

    2008-01-01

    A comparison was made between the efficiency of low doses of peracetic acid (PAA: 1.5 mg/l) and chlorine dioxide (ClO(2): 1.5 and 2.0 mg/l) in the disinfection of secondary effluents of a wastewater treatment plant. Peracetic acid was seen to be more active than chlorine dioxide and less influenced by the organic content of the waste. Both PAA and ClO(2) (2.0 mg/l) lead to a higher reduction in total and faecal coliforms and E. coli than in phages (somatic coliphages and F-specific RNA bacteriophages) and enterococci. Detection of faecal coliforms and E. coli should therefore be accompanied by a search for these more resistant microorganisms when assessing the conformity of wastewater for irrigation use, or for discharge into surface waters. Coliphages are also considered suitable indicators of the presence of enteric viruses. Although the application of low doses of both disinfectants offers advantages in terms of costs and produces not significant quantities of byproducts, it is not sufficient to obtain wastewater suitable for irrigation according to the Italian norms (E. coli < 10/100 ml in 80 % of samples and <100/100 ml in the remaining samples). Around 65 % of the samples, however, presented concentrations of E. coli lower than the limit of 5,000/100 ml established by Italian norms for discharge into surface waters.

  7. Cleaning and disinfection of equipment for gastrointestinal endoscopy. Report of a Working Party of the British Society of Gastroenterology Endoscopy Committee.

    PubMed

    1998-04-01

    Two per cent glutaraldehyde is the most commonly used disinfectant in endoscopy units within the UK. Unfortunately adverse reactions to glutaraldehyde are common among endoscopy personnel and the Health and Safety Commission has recommended substantial reductions in atmospheric levels of glutaraldehyde in order to comply with the Control of Substances Hazardous to Health Regulations, 1994. The Working Party addressed ways of eliminating or minimising exposure to glutaraldehyde in endoscopy units by reviewing alternative disinfectants and the use of automated washer/disinfectors. Alternatives to glutaraldehyde must be at least as microbicidal as glutaraldehyde, non-irritating and compatible with endoscope components and decontamination equipment. Peracetic acid is a highly effective disinfectant and may be a suitable alternative to glutaraldehyde. Peracetic acid has a vinegary-like odour and is claimed to be less irritating than glutaraldehyde. Experience with this agent remains relatively limited and the Working Party recommends that peracetic acid should be used in sealed or exhaust ventilated facilities until further experience is obtained. It is considerably more expensive than glutaraldehyde, is less stable and large volumes have to be stored. It causes cosmetic (but not functional) damage to endoscopes and is not compatible with some washer/ disinfectors. Chlorine dioxide is a powerful oxidising agent and highly effective as a disinfectant. Once activated it must be stored in sealed containers with little head space. Fumes cause irritation and sealed or exhaust ventilated facilities are necessary. The agent may damage some metallic and polymer components of endoscopes and automated washer/disinfectors and compatibility should be established with equipment manufacturers before the agent is used. Other disinfectants such as peroxygen compounds and quaternary ammonium derivatives are less suitable because of unsatisfactory mycobactericidal and/or virucidal activity, or incompatibility with endoscopes and automated washer/disinfectors. Alcohol is effective but, on prolonged contact, is damaging to lens cements. It is also flammable and therefore unsuitable for use in large quantities in automated systems. Superoxidised water (Sterilox) is an electrochemical solution (anolyte) containing a mixture of radicals with strong oxidising properties. It is highly microbicidal when freshly generated, provided items are thoroughly clean and strict generation criteria are met--that is, current, pH, redox potential. It seems to be safe for users and provided field trials substantiate laboratory efficacy tests, and the agent is non-damaging, it too may become an alternative to glutaraldehyde. When 2% glutaraldehyde is used for manual and automated disinfection, 10 minutes' immersion is recommended for endoscopes before the session and between patients. This will destroy vegetative bacteria and viruses (including hepatitis B virus (HBV) and HIV). A five minute contact period is recommended for 0.35% peracetic acid and for chlorine dioxide (1100 ppm av ClO2), but if immersed for 10 minutes sporicidal activity will also be achieved. At the end of each session 20 minutes' immersion in glutaraldehyde or five minutes in peracetic acid or chlorine dioxide is recommended. Microbiological studies show that 20 minutes of exposure to 2% glutaraldehyde destroys most organisms, including Mycobacterium tuberculosis. The Working Party concludes therefore that immersion of the endoscope in 2% glutaraldehyde for 20 minutes is sufficient for endoscopy involving patients with AIDS and other immunodeficiency states or pulmonary tuberculosis. Similarly, 20 minutes' immersion is recommended at the start of the list and between cases for endoscopic retrograde cholangiopancreatography (ERCP) when high level disinfection is required. Cleaning and disinfection of endoscopes should be undertaken by trained staff in a dedicated room. Thorough cleaning with detergent

  8. Antimicrobial Activity of Chlorhexidine, Peracetic acid/ Peroxide hydrogen and Alcohol based compound on Isolated Bacteria in Madani Heart Hospital, Tabriz, Azerbaijan, Iran

    PubMed Central

    Ghotaslou, Reza; Bahrami, Nashmil

    2012-01-01

    Purpose: The aim of present study was to investigate the effect of chemical agents on the clinical isolates in Madani Heart Hospital, Tabriz, Iran. Methods: The minimum bactericide concentration (MBC) of disinfectants including chlorhexidine (Fort), peracetic acid (Micro) and an alcohol based compound (Deconex) on selected bacteria at various dilutions were determined by the standard suspension technique. Results: MBC of Micro, Fort and Deconex were 2-128 mg/L, 2-64 mg/L and 4 - 32 mg/L, respectively. The Gram negative bacteria were more resistance to disinfectant relation to Gram positive bacteria. Conclusion: The results showed that these agents are able to eradicate the bacteria and they can be used lonely. PMID:24312771

  9. Method for rapid detection and identification of chaetomium and evaluation of resistance to peracetic acid.

    PubMed

    Nakayama, Motokazu; Hosoya, Kouichi; Tomiyama, Daisuke; Tsugukuni, Takashi; Matsuzawa, Tetsuhiro; Imanishi, Yumi; Yaguchi, Takashi

    2013-06-01

    In the beverage industry, peracetic acid has been increasingly used as a disinfectant for the filling machinery and environment due to merits of leaving no residue, it is safe for humans, and its antiseptic effect against fungi and endospores of bacteria. Recently, Chaetomium globosum and Chaetomium funicola were reported resistant to peracetic acid; however, little is known concerning the detail of peracetic acid resistance. Therefore, we assessed the peracetic acid resistance of the species of Chaetomium and related genera under identical conditions and made a thorough observation of the microstructure of their ascospores by transmission electron microscopy. The results of analyses revealed that C. globosum and C. funicola showed the high resistance to peracetic acid (a 1-D antiseptic effect after 900 s and 3-D antiseptic effect after 900 s) and had thick cell walls of ascospores that can impede the action mechanism of peracetic acid. We also developed specific primers to detect the C. globosum clade and identify C. funicola by using PCR to amplify the β-tubulin gene. PCR with the primer sets designed for C. globosum (Chae 4F/4R) and C. funicola (Cfu 2F/2R) amplified PCR products specific for the C. globosum clade and C. funicola, respectively. PCR with these two primer sets did not detect other fungi involved in food spoilage and environmental contamination. This detection and identification method is rapid and simple, with extremely high specificity.

  10. The Effects of Subacute Exposure of Peracetic Acid on Lipid Peroxidation and Hepatic Enzymes in Wistar Rats

    PubMed Central

    Marjani, Abdoljalal; Golalipour, Mohammad J.; Gharravi, Anneh M.

    2010-01-01

    Objectives This study was undertaken to determine the effect of subacute exposure of peracetic acid on lipid peroxidation and hepatic enzymes in Wistar rats. Methods 48 male animals in Treatment Group I, II and III received 0.2%, 2% and 20% peracetic acid daily for 2 and 4 weeks. Results Serum malondialdehyde increased and Alanine Transaminase and Aspartate Transaminase decreased significantly in groups 2 and 3, compared to the control group. The malondialdehyde, Alanine Transaminase and Aspartate Transaminase with 0.2% and 2% doses of peracetic acid for 2 weeks do not lead to the alteration of malondialdehyde and enzyme activities. Conclusion This study demonstrated that the enhancement of malondialdehyde could provide an oxidative damage induced by disinfectant peroxidation at 20% and 2% doses at 2 and 4 weeks. The consumption of peroxidation with 20% for 2 weeks and 2% for 4 weeks can cause the increase of malondialdehyde and the decrease of enzyme activities, respectively. PMID:22043353

  11. Inactivation kinetics of spores of Bacillus cereus strains treated by a peracetic acid-based disinfectant at different concentrations and temperatures.

    PubMed

    Sudhaus, Nadine; Pina-Pérez, Maria Consuelo; Martínez, Antonio; Klein, Günter

    2012-05-01

    The purpose of this study was to assess the effect of a commercial peracetic acid-based disinfectant against spores of Bacillus cereus, to identify the most influential factor for the final number of microorganisms after different disinfection procedures, and to evaluate the nature of the inactivation kinetics. The spores of four different strains of B. cereus (DSM 318, 4312, 4313, and 4384) were treated with five different disinfectant concentrations (0.25%, 0.5%, 1.0%, 1.5%, and 2.0% [w/v]) at three different temperatures (10°C, 15°C, and 20°C) with or without protein load. A higher temperature and PES 15/23 concentration resulted in a higher inactivation. Inactivation of B. cereus strain 4312 was around 2 log₁₀ cycles at 10°C and around 7 log₁₀ at 20°C (conc=1% [w/v] PAA; t=60 min; without protein). The protein load at higher concentrations did not significantly reduce the efficacy of the disinfectant (p>0.05). This article indicates the applicability of the Weibull model to fit the B. cereus disinfectant survival curves. A Monte Carlo simulation was used to carry out a sensitivity analysis, which revealed the most influential factors affecting the final number of microorganisms after the disinfection process.

  12. Hygienisierung in der Fischzucht mittels Per-essigsäure (Disinfection of water with PAA: State of the investigations)

    USDA-ARS?s Scientific Manuscript database

    There are very few therapeutic agents against aquaculture ectoparasites in Germany. Peracetic Acid (PAA) has been referred to as the best disinfective agent in the world, but it has not been used much here in aquaculture. We currently use this compound in ‘treatment crisis’ situations because ther...

  13. Long-term effects of disinfectants on the community composition of drinking water biofilms.

    PubMed

    Roeder, Rosemarie S; Lenz, Johannes; Tarne, Peter; Gebel, Jürgen; Exner, Martin; Szewzyk, Ulrich

    2010-06-01

    Numerous investigations have demonstrated efficiencies of different disinfection methods, but until now only little is known about long-term effects on community compositions of drinking water biofilms. Changes in the community structure, especially regrowth of hygienically relevant microorganisms could be critical for the drinking water quality. In this study the long-term effect of disinfection methods on biofilm communities in drinking water systems was analysed. Old drinking water biofilms grown in silicone tubes were exposed to different preparations of disinfectants (free chlorine, chlorine dioxide, hydrogen peroxide combined with fruit acid, silver and silver with peracetic acid, respectively) and subsequently further exposed in the original drinking water. The comparison of the treated and regrown biofilm populations with untreated ones by the DNA-fingerprinting method denaturing gradient gel electrophoresis (DGGE) revealed a considerable population shift caused by the disinfectants. The disinfection methods induced a selection pressure on the biofilm populations depending on the composition and concentrations. The similarities between the treated and untreated biofilms were generally low. Compared to preparations with peracetic acid the disinfection with hydrogen peroxide and silver resulted in higher similarities of the treated and untreated biofilms, but the microbial diversity increased. It can be concluded that the disinfectants have a major impact on the drinking water biofilm communities and that possibly the intervention selects persisters and microorganisms, which can live on the residuals of the dead biofilm cells. For the evaluation of the efficiency of disinfection methods in drinking water installations it is necessary not only to consider reduction of certain bacteria but also to pay attention to the biofilm community. Copyright 2010 Elsevier GmbH. All rights reserved.

  14. Biofilm formation by Staphylococcus aureus and Salmonella spp. under mono and dual-species conditions and their sensitivity to cetrimonium bromide, peracetic acid and sodium hypochlorite.

    PubMed

    Iñiguez-Moreno, Maricarmen; Gutiérrez-Lomelí, Melesio; Guerrero-Medina, Pedro Javier; Avila-Novoa, María Guadalupe

    The aim of this study was evaluated the biofilm formation by Staphylococcus aureus 4E and Salmonella spp. under mono and dual-species biofilms, onto stainless steel 316 (SS) and polypropylene B (PP), and their sensitivity to cetrimonium bromide, peracetic acid and sodium hypochlorite. The biofilms were developed by immersion of the surfaces in TSB by 10 d at 37°C. The results showed that in monospecies biofilms the type of surface not affected the cellular density (p>0.05). However, in dual-species biofilms on PP the adhesion of Salmonella spp. was favored, 7.61±0.13Log 10 CFU/cm 2 , compared with monospecies biofilms onto the same surface, 5.91±0.44Log 10 CFU/cm 2 (p<0.05). The mono and dual-species biofilms were subjected to disinfection treatments; and the most effective disinfectant was peracetic acid (3500ppm), reducing by more than 5Log 10 CFU/cm 2 , while the least effective was cetrimonium bromide. In addition, S. aureus 4E and Salmonella spp. were more resistant to the disinfectants in mono than in dual-species biofilms (p<0.05). Therefore, the interspecies interactions between S. aureus 4E and Salmonella spp. had a negative effect on the antimicrobial resistance of each microorganism, compared with the monospecies biofilms. Copyright © 2017 Sociedade Brasileira de Microbiologia. Published by Elsevier Editora Ltda. All rights reserved.

  15. Disinfection of an advanced primary effluent with peracetic acid and ultraviolet combined treatment: a continuous-flow pilot plant study.

    PubMed

    González, Abelardo; Gehr, Ronald; Vaca, Mabel; López, Raymundo

    2012-03-01

    Disinfection of an advanced primary effluent using a continuous-flow combined peracetic acid/ultraviolet (PAA/UV) radiation system was evaluated. The purpose was to determine whether the maximum microbial content, established under Mexican standards for treated wastewaters meant for reuse--less than 240 most probable number fecal coliforms (FC)/100 mL--could be feasibly accomplished using either disinfectant individually, or the combined PAA/UV system. This meant achieving reduction of up to 5 logs, considering initial concentrations of 6.4 x 10(+6) to 5.8 x 10(+7) colony forming units/100 mL. During the tests performed under these experiments, total coliforms (TC) were counted because FC, at the most, will be equal to TC. Peracetic acid disinfection achieved less than 1.5 logs TC reduction when the C(t) x t product was less than 2.26 mg x minimum (min)/L; 3.8 logs for C(t) x t 4.40 mg x min/L; and 5.9 logs for C(t) x t 24.2 mg x min/L. In continuous-flow UV irradiation tests, at a low-operating flow (21 L/min; conditions which produced an average UV fluence of 13.0 mJ/cm2), the highest TC reduction was close to 2.5 logs. The only condition that produced a disinfection efficiency of approximately 5 logs, when both disinfection agents were used together, was the combined process dosing 30 mg PAA/L at a pilot plant flow of 21 L/min and contact time of 10 minutes to attain an average C(t) x t product of 24.2 mg x min/L and an average UV fluence of 13 mJ/cm2. There was no conclusive evidence of a synergistic effect when both disinfectants were employed in combination as compared to the individual effects achieved when used separately, but this does not take into account the nonlinearity (tailing-off) of the dose-response curve.

  16. Test methods for estimating the efficacy of the fast-acting disinfectant peracetic acid on surfaces of personal protective equipment.

    PubMed

    Lemmer, K; Howaldt, S; Heinrich, R; Roder, A; Pauli, G; Dorner, B G; Pauly, D; Mielke, M; Schwebke, I; Grunow, R

    2017-11-01

    The work aimed at developing and evaluating practically relevant methods for testing of disinfectants on contaminated personal protective equipment (PPE). Carriers were prepared from PPE fabrics and contaminated with Bacillus subtilis spores. Peracetic acid (PAA) was applied as a suitable disinfectant. In method 1, the contaminated carrier was submerged in PAA solution; in method 2, the contaminated area was covered with PAA; and in method 3, PAA, preferentially combined with a surfactant, was dispersed as a thin layer. In each method, 0·5-1% PAA reduced the viability of spores by a factor of ≥6 log 10 within 3 min. The technique of the most realistic method 3 proved to be effective at low temperatures and also with a high organic load. Vaccinia virus and Adenovirus were inactivated with 0·05-0·1% PAA by up to ≥6 log 10 within 1 min. The cytotoxicity of ricin was considerably reduced by 2% PAA within 15 min of exposure. PAA/detergent mixture enabled to cover hydrophobic PPE surfaces with a thin and yet effective disinfectant layer. The test methods are objective tools for estimating the biocidal efficacy of disinfectants on hydrophobic flexible surfaces. © 2017 The Society for Applied Microbiology.

  17. [Disinfection efficiency of peracetic acid, alone and in combination with hypochlorite, against Mycobacterium avium in drinking water].

    PubMed

    Schiavano, G F; Sisti, M; De Santi, M; Brandi, G

    2006-01-01

    Peracetic acid (PAA) is a disinfectant with a wide spectrum of antimicrobial activity, but little is known about the feasibility of using it in the field of drinking water treatment. The aim of this study has been assess disinfectant efficacy of PAA, alone or in combination with hypochlorite, against M. avium in drinking water M. avium is a common opportunistic pathogen in immunocompromised subjects that is able to survive and grow in drinking water distribution systems. In this study PAA did not show appreciable activity against the greater number of tested strains (16/21) up to 5 ppm of PAA, a weak activity was seen on 4 strains, while a significant reduction in viable cells (about 50%) was seen only on 1 strain after 48 h of treatment with 5 ppm of PAA. We also evidenced that M. avium was unaffected by chlorine concentration usually present in drinking water distribution system. Finally, the combination of PAA and sodium hypochlorite did not promote enhanced antimicrobial efficacy respect to the single disinfectants. In conclusion, our result would indicate that PAA is an unlikely candidate for the disinfection of drinking water from M. avium and further strategies are required to eliminate M. avium from drinking water system.

  18. Virucidal efficacy of peracetic acid for instrument disinfection.

    PubMed

    Becker, Britta; Brill, Florian H H; Todt, Daniel; Steinmann, Eike; Lenz, Johannes; Paulmann, Dajana; Bischoff, Birte; Steinmann, Jochen

    2017-01-01

    Various peracetic-acid (PAA)-based products for processing flexible endoscopes on the market are often based on a two-component system including a cleaning step before the addition of PAA as disinfectant. The peracetic acid concentrations in these formulations from different manufacturers are ranging from 400 to 1500 ppm (part per million). These products are used at temperatures between 20 °C and 37 °C. Since information on the virus-inactivating properties of peracetic acid at different concentrations and temperature is missing, it was the aim of the study to evaluate peracetic acid solutions against test viruses using the quantitative suspension test, EN 14476. In addition, further studies were performed with the recently established European pre norm (prEN 17111:2017) describing a carrier assay for simulating practical conditions using frosted glass. In the first step of examination, different PAA solutions between 400 and 1500 ppm were tested at 20 °C, 25 °C, and 35 °C with three test viruses (adenovirus, murine norovirus and poliovirus) necessary for creating a virucidal action according to the European Norm, EN 14476. A second step for simulating practical conditions based on prEN 17111:2017 followed by spreading a test virus together with soil load onto a glass carrier which was immerged into a peracetic acid solution. A fixed exposure time of five minutes was used in all experiments. In the quantitative suspension test 1500 ppm PAA solution was needed at 35 °C for five minutes for the inactivation of poliovirus, whereas only 400 ppm at 20 °C for adeno- and murine norovirus were necessary. In the carrier assay 400 ppm peracetic acid at 20 °C were sufficient for adenovirus inactivation, whereas 600 ppm PAA were needed at 25 °C and 35 °C and 1000 ppm at 20 °C for murine norovirus. A PAA solution with 1000 ppm at 35 °C was required for complete inactivation of poliovirus. However, a dramatically decrease of titer after the drying and immerging could be observed. In consequence, a four log reduction of poliovirus titer could not be achieved in the carrier test. In summary, 1500 ppm PAA at 35 °C was necessary for a virucidal action in the quantitative suspension test. After passing the requirements of the suspension test, additional examinations with adeno- and murine norovirus on glass carriers based on prEN 17111:2017 will not additionally contribute to the final claim of an instrument disinfectant for virucidal efficacy. This is due to the great stability of poliovirus in the preceded quantitative suspension test and the fact that poliovirus could not serve as test virus in the following carrier assay.

  19. Results of a Pilot-Scale Disinfection Test using Peracetic Acid (PAA) at the Oak Ridge National Laboratory (ORNL) Sewage Treatment Plant (STP)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taylor, Paul Allen

    The purpose of this report is to present the results of a small pilot-scale test using PAA to disinfect a side stream of the effluent from the ORNL STP. These results provide the basis for requesting approval for full-scale use of PAA at the ORNL STP.

  20. Effects of a peracetic acid disinfection protocol on the biocompatibility and biomechanical properties of human patellar tendon allografts.

    PubMed

    Lomas, R J; Jennings, L M; Fisher, J; Kearney, J N

    2004-01-01

    Patellar tendon allografts, retrieved from cadaveric human donors, are widely used for replacement of damaged cruciate ligaments. In common with other tissue allografts originating from cadaveric donors, there are concerns regarding the potential for disease transmission from the donor to the recipient. Additionally, retrieval and subsequent processing protocols expose the graft to the risk of environmental contamination. For these reasons, disinfection or sterilisation protocols are necessary for these grafts before they are used clinically. A high-level disinfection protocol, utilising peracetic acid (PAA), has been developed and investigated for its effects on the biocompatibility and biomechanics of the patellar tendon allografts. PAA disinfection did not render the grafts either cytotoxic or liable to provoke an inflammatory response as assessed in vitro . However, the protocol was shown to increase the size of gaps between the tendon fibres in the matrix and render the grafts more susceptible to digestion with collagenase. Biomechanical studies of the tendons showed that PAA treatment had no effect on the ultimate tensile stress or Young's modulus of the tendons, and that ultimate strain was significantly higher in PAA treated tendons.

  1. Thermodynamic properties of an emerging chemical disinfectant, peracetic acid.

    PubMed

    Zhang, Chiqian; Brown, Pamela J B; Hu, Zhiqiang

    2018-04-15

    Peracetic acid (PAA or CH 3 COOOH) is an emerging disinfectant with a low potential to form carcinogenic disinfection by-products (DBPs). Basic thermodynamic properties of PAA are, however, absent or inconsistently reported in the literature. This review aimed to summarize important thermodynamic properties of PAA, including standard Gibbs energy of formation and oxidation-reduction (redox) potential. The standard Gibbs energies of formation of CH 3 COOOH (aq) , CH 3 COOOH (g) , CH 3 COOOH (l) , and CH 3 COOO (aq) - are -299.41kJ·mol -1 , -283.02kJ·mol -1 , -276.10kJ·mol -1 , and -252.60kJ·mol -1 , respectively. The standard redox potentials of PAA are 1.748V and 1.005V vs. standard hydrogen electrode (SHE) at pH 0 and pH 14, respectively. Under biochemical standard state conditions (pH 7, 25°C, 101,325Pa), PAA has a redox potential of 1.385V vs. SHE, higher than many disinfectants. Finally, the environmental implications of the thermodynamic properties of PAA were systematically discussed. Those properties can be used to predict the physicochemical and biological behavior of aquatic systems exposed to PAA. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Peracetic acid (PAA) disinfection of primary, secondary and tertiary treated municipal wastewaters.

    PubMed

    Koivunen, J; Heinonen-Tanski, H

    2005-11-01

    The efficiency of peracetic acid (PAA) disinfection against enteric bacteria and viruses in municipal wastewaters was studied in pilot-scale. Disinfection pilot-plant was fed with the primary or secondary effluent of Kuopio municipal wastewater treatment plant or tertiary effluent from the pilot-scale dissolved air flotation (DAF) unit. Disinfectant doses ranged from 2 to 7 mg/l PAA in the secondary and tertiary effluents, and from 5 to 15 mg/l PAA in the primary effluents. Disinfection contact times were 4-27 min. Disinfection of secondary and tertiary effluents with 2-7 mg/l PAA and 27 min contact time achieved around 3 log reductions of total coliforms (TC) and enterococci (EC). PAA disinfection also significantly improved the hygienic quality of the primary effluents: 10-15 mg/l PAA achieved 3-4 log reductions of TC and EC, 5 mg/l PAA resulting in below 2 log reductions. F-RNA coliphages were more resistant against the PAA disinfection and around 1 log reductions of these enteric viruses were typically achieved in the disinfection treatments of the primary, secondary and tertiary effluents. Most of the microbial reductions occurred during the first 4-18 min of contact time, depending on the PAA dose and microorganism. The PAA disinfection efficiency remained relatively constant in the secondary and tertiary effluents, despite of small changes of wastewater quality (COD, SS, turbidity, 253.7 nm transmittance) or temperature. The disinfection efficiency clearly decreased in the primary effluents with substantially higher microbial, organic matter and suspended solids concentrations. The results demonstrated that PAA could be a good alternative disinfection method for elimination of enteric microbes from different wastewaters.

  3. [Peracetic acid: alternative to the sterilization of bronchofibroscopes].

    PubMed

    Villate, J I; Barrón, J; Zalacaín, R; Urcelay, M I; Hernández, J M; Argumedo, M

    1997-03-01

    The Steris system for cold sterilization with peracetic acid was evaluated by effecting a series of contaminations of a fiberoptic bronchoscope (FB) with specimens of Pseudomonas aeruginosa, Acinetobacter baumanii and Mycobacterium kansasi. The FB was contaminated 24 times, 8 times by each microorganism, using specimens containing more than 10(8) cfu/ml. After fixing the secretions on the FB and washing it with enzyme soap, the BF was sterilized. Specimens were taken for culturing after contamination of the FB, after washing, immediately after sterilization and 1 hour after sterilization. No microorganism growth of any of the samples was detected either immediately after sterilization or one hour later. Microbiological data confirmed contamination of the FB after aspiration and fixation of the inoculate. Chemical and biological tests with B. stearothermophilus spores as specified by the manufacturer were correct in all cases: 24 contaminations and 52 processes of prior training. The efficacy of washing with enzyme soap before sterilization stands out. In 14 of the 24 samples, culture was negative after washing and in 7 the concentration of microorganisms was less than 500 cfu/ml, which confirms the need for appropriate washing before any disinfection or sterilization process is begun. In conclusion, the Steris system based on peracetic acid is an alternative to other systems for cold sterilization or high level disinfection.

  4. Growth inhibition of Aeromonas salmonicida and Yersinia ruckeri by disinfectants containing peracetic acid.

    PubMed

    Meinelt, Thomas; Phan, Thy-My; Behrens, Sascha; Wienke, Andreas; Pedersen, Lars-Flemming; Liu, Dibo; Straus, David L

    2015-04-08

    Peracetic acid (PAA) is a therapeutic agent used for disinfection in aquaculture, but it must be investigated thoroughly in order to mitigate diseases without harming the fish. Successful disinfectants (like PAA) should not leave dangerous residues in the environment in order to successfully contribute to sustainable aquaculture. The aim of our study was to compare the effectiveness of 6 commercial PAA products with different molecular PAA:H2O2 ratios to reduce bacterial growth of Aeromonas salmonicida and Yersinia ruckeri and to determine effective concentrations and exposure times. All products reduced colony-forming units (CFUs) of A. salmonicida and Y. ruckeri. Products with higher molecular PAA:H2O2 ratios inhibited growth better than products with lower molecular PAA:H2O2 ratios at the same PAA concentration; this indicates that H2O2 is not the driving force in the reduction of A. salmonicida and Y. ruckeri growth by PAA in vitro. The practical application of the products with high molecular PAA:H2O2 ratios should be prioritized if these pathogens are diagnosed.

  5. The differential effects of heat-shocking on the viability of spores from Bacillus anthracis, Bacillus subtilis, and Clostridium sporogenes after treatment with peracetic acid- and glutaraldehyde-based disinfectants

    PubMed Central

    March, Jordon K; Pratt, Michael D; Lowe, Chinn-Woan; Cohen, Marissa N; Satterfield, Benjamin A; Schaalje, Bruce; O'Neill, Kim L; Robison, Richard A

    2015-01-01

    This study investigated (1) the susceptibility of Bacillus anthracis (Ames strain), Bacillus subtilis (ATCC 19659), and Clostridium sporogenes (ATCC 3584) spores to commercially available peracetic acid (PAA)- and glutaraldehyde (GA)-based disinfectants, (2) the effects that heat-shocking spores after treatment with these disinfectants has on spore recovery, and (3) the timing of heat-shocking after disinfectant treatment that promotes the optimal recovery of spores deposited on carriers. Suspension tests were used to obtain inactivation kinetics for the disinfectants against three spore types. The effects of heat-shocking spores after disinfectant treatment were also determined. Generalized linear mixed models were used to estimate 6-log reduction times for each spore type, disinfectant, and heat treatment combination. Reduction times were compared statistically using the delta method. Carrier tests were performed according to AOAC Official Method 966.04 and a modified version that employed immediate heat-shocking after disinfectant treatment. Carrier test results were analyzed using Fisher's exact test. PAA-based disinfectants had significantly shorter 6-log reduction times than the GA-based disinfectant. Heat-shocking B. anthracis spores after PAA treatment resulted in significantly shorter 6-log reduction times. Conversely, heat-shocking B. subtilis spores after PAA treatment resulted in significantly longer 6-log reduction times. Significant interactions were also observed between spore type, disinfectant, and heat treatment combinations. Immediately heat-shocking spore carriers after disinfectant treatment produced greater spore recovery. Sporicidal activities of disinfectants were not consistent across spore species. The effects of heat-shocking spores after disinfectant treatment were dependent on both disinfectant and spore species. Caution must be used when extrapolating sporicidal data of disinfectants from one spore species to another. Heat-shocking provides a more accurate picture of spore survival for only some disinfectant/spore combinations. Collaborative studies should be conducted to further examine a revision of AOAC Official Method 966.04 relative to heat-shocking. PMID:26185111

  6. Impact of UV and peracetic acid disinfection on the prevalence of virulence and antimicrobial resistance genes in uropathogenic Escherichia coli in wastewater effluents.

    PubMed

    Biswal, Basanta Kumar; Khairallah, Ramzi; Bibi, Kareem; Mazza, Alberto; Gehr, Ronald; Masson, Luke; Frigon, Dominic

    2014-06-01

    Wastewater discharges may increase the populations of pathogens, including Escherichia coli, and of antimicrobial-resistant strains in receiving waters. This study investigated the impact of UV and peracetic acid (PAA) disinfection on the prevalence of virulence and antimicrobial resistance genes in uropathogenic Escherichia coli (UPEC), the most abundant E. coli pathotype in municipal wastewaters. Laboratory disinfection experiments were conducted on wastewater treated by physicochemical, activated sludge, or biofiltration processes; 1,766 E. coli isolates were obtained for the evaluation. The target disinfection level was 200 CFU/100 ml, resulting in UV and PAA doses of 7 to 30 mJ/cm(2) and 0.9 to 2.0 mg/liter, respectively. The proportions of UPECs were reduced in all samples after disinfection, with an average reduction by UV of 55% (range, 22% to 80%) and by PAA of 52% (range, 11% to 100%). Analysis of urovirulence genes revealed that the decline in the UPEC populations was not associated with any particular virulence factor. A positive association was found between the occurrence of urovirulence and antimicrobial resistance genes (ARGs). However, the changes in the prevalence of ARGs in potential UPECs were different following disinfection, i.e., UV appears to have had no effect, while PAA significantly reduced the ARG levels. Thus, this study showed that both UV and PAA disinfections reduced the proportion of UPECs and that PAA disinfection also reduced the proportion of antimicrobial resistance gene-carrying UPEC pathotypes in municipal wastewaters.

  7. Impact of UV and Peracetic Acid Disinfection on the Prevalence of Virulence and Antimicrobial Resistance Genes in Uropathogenic Escherichia coli in Wastewater Effluents

    PubMed Central

    Biswal, Basanta Kumar; Khairallah, Ramzi; Bibi, Kareem; Mazza, Alberto; Gehr, Ronald; Masson, Luke

    2014-01-01

    Wastewater discharges may increase the populations of pathogens, including Escherichia coli, and of antimicrobial-resistant strains in receiving waters. This study investigated the impact of UV and peracetic acid (PAA) disinfection on the prevalence of virulence and antimicrobial resistance genes in uropathogenic Escherichia coli (UPEC), the most abundant E. coli pathotype in municipal wastewaters. Laboratory disinfection experiments were conducted on wastewater treated by physicochemical, activated sludge, or biofiltration processes; 1,766 E. coli isolates were obtained for the evaluation. The target disinfection level was 200 CFU/100 ml, resulting in UV and PAA doses of 7 to 30 mJ/cm2 and 0.9 to 2.0 mg/liter, respectively. The proportions of UPECs were reduced in all samples after disinfection, with an average reduction by UV of 55% (range, 22% to 80%) and by PAA of 52% (range, 11% to 100%). Analysis of urovirulence genes revealed that the decline in the UPEC populations was not associated with any particular virulence factor. A positive association was found between the occurrence of urovirulence and antimicrobial resistance genes (ARGs). However, the changes in the prevalence of ARGs in potential UPECs were different following disinfection, i.e., UV appears to have had no effect, while PAA significantly reduced the ARG levels. Thus, this study showed that both UV and PAA disinfections reduced the proportion of UPECs and that PAA disinfection also reduced the proportion of antimicrobial resistance gene-carrying UPEC pathotypes in municipal wastewaters. PMID:24727265

  8. Comparative lethality kinetic curves and predictive models of F-value for Listeria monocytogenes using different sanitizers

    PubMed Central

    Beltrame, Cezar A; Kubiak, Gabriela B; Rottava, Ieda; Toniazzo, Geciane; Cansian, Rogério L; Lerin, Lindomar A; de Oliveira, Débora; Treichel, Helen

    2013-01-01

    The objective of this work was to evaluate the kinetic of inactivation of Listeria monocytogenes using peracetic acid, chlorhexidine, and organic acids as active agent, determining the respective D-, Z-, and F-values. From our knowledge, these important results from an industrial view point are not available in the current literature, mainly for organic acids, pointing out the main contribution of the present work. Lower D-values were obtained for peracetic acid and chlorhexidine, compared with the organic acids. For the reduction of 6 log10 of L. monocytogenes using peracetic acid, at 0.2, 0.1, and 0.05% are necessary 7.08, 31.08, and 130.44 min of contact, respectively. The mathematical models of F-values showed that at concentrations lower than 0.15% one can verify an exponential increase in F-values, for both de chlorhexidine and peracetic acid. The organic acids presented a linear behavior, showing slight variation in F-values, is even more effective in under dosage. The results obtained are of fundamental importance in terms of industrial strategy for sanitization procedure, permitting to choose the best relation product concentration/exposure time, aiming at reducing costs without compromising the disinfectant efficiency. PMID:24804011

  9. Disinfection of corrugated tubing by ozone and ultrasound in mechanically ventilated tracheostomized patients.

    PubMed

    Lopes, M S; Ferreira, J R F; da Silva, K B; de Oliveira Bacelar Simplício, I; de Lima, C J; Fernandes, A B

    2015-08-01

    Medical equipment coming into contact with non-intact skin or mucous membranes is classified as semi-critical material. This equipment requires at least high-level disinfection, as the major risk in all invasive procedures is the introduction of pathogenic microbes causing hospital-associated infections. To evaluate the capacity of ozone gas and ultrasound to disinfect semi-critical, thermally sensitive material. Used corrugated tubing from mechanically ventilated tracheostomized patients in the intensive care unit was obtained. Enzymatic detergent was applied for 15min before different disinfection techniques were evaluated as follows: Group A (0.2% peracetic acid); Group B (ultrasound for 60min); Group C (application of ozone gas at a concentration of 33mg/L for 15min); Group D (ultrasound for 30min and ozone for 15min); Group E (ultrasound for 60min and ozone for 15min). Application of ultrasound for 60min reduced the level of microbial contamination by 4 log10, whereas ozone alone and the other two combined techniques (ultrasound and ozone) and the peracetic acid reduced the level of microbial contamination by 5 log10. Ozone was the most advantageous technique taking into consideration processing time, ease of use, effectiveness, and cost. The use of ozone gas to disinfect semi-critical material proved to be technically feasible and extremely promising. Copyright © 2015 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  10. Effect of peracetic acid, ultraviolet radiation, nanofiltration-chlorine in the disinfection of a non conventional source of water (Tula Valley).

    PubMed

    Trujillo, J; Barrios, J A; Jimenez, B

    2008-01-01

    Water supply for human consumption requires certain quality that reduces health risks to consumers. In this sense, the process of disinfection plays an important role in the elimination of pathogenic microorganisms. Even though chlorination is the most applied process based on its effectiveness and cost, its application is being questioned considering the formation of disinfection by-products (DBPs). Therefore, alternative disinfectants are being evaluated and some treatment processes have been proposed to remove DBPs precursors (organic matter. This paper reports the results of disinfection of a non conventional source of water (aquifer recharged unintentionally with raw wastewater) with peracetic acid (PAA) and ultraviolet radiation (UV) as well as nanofiltration (NF) followed by chlorination to produce safe drinking water. The results showed that a dose of 2 mg/L PAA was needed to eliminate total and faecal coliforms. For UV light, a dose of 12.40 mWs/cm2 reduced total and faecal coliforms below the detection limit. On the other hand, chlorine demand of water before NF was 1.1-1.3 mg/L with a trihalomethane formation potential (THMFP) of 118.62 microg/L, in contrast with chlorination after NF where the demand was 0.5 mg/L and THMFP of 17.64 microg/L. The recommended scheme is nanofiltration + chlorination.

  11. [Decontamination of dental unit waterlines using disinfectants and filters].

    PubMed

    Monarca, S; Garusi, G; Gigola, P; Spampinato, L; Zani, C; Sapelli, P L

    2002-10-01

    Bacterial contamination of the dental unit water system can become a health problem for patients, particularly if they are immunodepressed. The present study has had the purpose of evaluating the effectiveness of methods of chemical decontamination using different disinfectants (peracetic acid, hydrogen peroxide, silver salts, chloramine T, glutaraldehyde T4) and methods of physical decontamination using synthetic membranes for the filtration of water. A preliminary removal procedure of the biofilm present in the waterline has been followed in a dental unit prepared on purpose for the research; subsequently different 2-week long maintenance procedures were applied using disinfectants injected by a pump and finally the bacterial contamination of the water flowing from the waterline was evaluated. The physical decontamination was performed using 0.22 mm membrane filters, which have been installed also in another dental unit, and the filtered water was analyzed to detect bacterial contamination. The preliminary procedure of biofilm removal succeeded obtaining germ-free water. Among the disinfectants used for the maintenance of the water quality only glutaraldehyde T4 was able to reduce the bacterial contamination under the limit suggested by the ADA. The membrane filter system was not able to purify the water, but when a disinfectant (peracetic acid) was used in the last part of the waterline good results were obtained. At present no decontamination system of dental waterline is available, and glutaraldehyde T4 seems to be the best disinfectant only if integrated with periodic biofilm removal for the maintenance of the water quality.

  12. Clinical and cost effectiveness of eight disinfection methods for terminal disinfection of hospital isolation rooms contaminated with Clostridium difficile 027.

    PubMed

    Doan, L; Forrest, H; Fakis, A; Craig, J; Claxton, L; Khare, M

    2012-10-01

    Clostridium difficile spores can survive in the environment for months or years, and contaminated environmental surfaces are important sources of nosocomial C. difficile transmission. To compare the clinical and cost effectiveness of eight C. difficile environmental disinfection methods for the terminal cleaning of hospital rooms contaminated with C. difficile spores. This was a novel randomized prospective study undertaken in three phases. Each empty hospital room was disinfected, then contaminated with C. difficile spores and disinfected with one of eight disinfection products: hydrogen peroxide vapour (HPV; Bioquell Q10) 350-700 parts per million (ppm); dry ozone at 25 ppm (Meditrox); 1000 ppm chlorine-releasing agent (Actichlor Plus); microfibre cloths (Vermop) used in combination with and without a chlorine-releasing agent; high temperature over heated dry atomized steam cleaning (Polti steam) in combination with a sanitizing solution (HPMed); steam cleaning (Osprey steam); and peracetic acid wipes (Clinell). Swabs were inoculated on to C. difficile-selective agar and colony counts were performed pre and post disinfection for each method. A cost-effectiveness analysis was also undertaken comparing all methods to the current method of 1000 ppm chlorine-releasing agent (Actichlor Plus). Products were ranked according to the log(10) reduction in colony count from contamination phase to disinfection. The three statistically significant most effective products were hydrogen peroxide (2.303); 1000 ppm chlorine-releasing agent (2.223) and peracetic acid wipes (2.134). The cheaper traditional method of using a chlorine-releasing agent for disinfection was as effective as modern methods. Copyright © 2012 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  13. Peracetic acid disinfection: a feasible alternative to wastewater chlorination.

    PubMed

    Rossi, S; Antonelli, M; Mezzanotte, V; Nurizzo, C

    2007-04-01

    The paper summarizes the results of a bench-scale study to evaluate the feasibility of using peracetic acid (PAA) as a substitute for sodium hypochlorite both for discharge into surface water and for agricultural reuse. Trials were carried out with increasing doses (1, 2, 3, 5, 10, and 15 mg/L) and contact times (6, 12, 18, 36, 42, and 54 minutes) to study disinfectant decay and bacterial removal and regrowth, using fecal coliform and Escherichia coli (E. coli) as process efficiency indicators. Peracetic acid decay kinetics was evaluated in tap water and wastewater; in both cases, PAA decays according to first-order kinetics with respect to time, and a correlation was found between PAA oxidative initial consumption and wastewater characteristics. The PAA disinfection efficiency was correlated with operating parameters (active concentration and contact time), testing different kinetic models. Two data groups displaying a different behavior on the basis of initial active concentration ranges (1 to 2 mg/L and 5 to 15 mg/L, respectively) can be outlined. Both groups had a "tailing-off" inactivation curve with respect to time, but the second one showed a greater inactivation rate. Moreover, the effect of contact time was greater at the lower doses. Hom's model, used separately for the two data groups, was found to best fit experimental data, and the disinfectant active concentration appears to be the main factor affecting log-survival ratios. Moreover, the S-model better explains the initial resistance of E. coli, especially at low active concentrations (< 2 mg/L) and short contact times (< 12 minutes). Microbial counts, performed by both traditional methods and flow cytometry, immediately and 5 hours after sample collection (both with or without residual PAA inactivation), showed that no appreciable regrowth took place after 5 hours, neither for coliform group bacteria, nor for total heterotrophic bacteria.

  14. Integration of an innovative biological treatment with physical or chemical disinfection for wastewater reuse.

    PubMed

    De Sanctis, Marco; Del Moro, Guido; Levantesi, Caterina; Luprano, Maria Laura; Di Iaconi, Claudio

    2016-02-01

    In the present paper, the effectiveness of a Sequencing Batch Biofilter Granular Reactor (SBBGR) and its integration with different disinfection strategies (UV irradiation, peracetic acid) for producing an effluent suitable for agricultural use was evaluated. The plant treated raw domestic sewage, and its performances were evaluated in terms of the removal efficiency of a wide group of physical, chemical and microbiological parameters. The SBBGR resulted really efficient in removing suspended solids, COD and nitrogen with an average effluent concentration of 5, 32 and 10 mg/L, respectively. Lower removal efficiency was observed for phosphorus with an average concentration in the effluent of 3 mg/L. Plant effluent was also characterized by an average electrical conductivity and sodium adsorption ratio of 680 μS/cm and 2.9, respectively. Therefore, according to these gross parameters, the SBBGR effluent was conformed to the national standards required in Italy for agricultural reuse. Moreover, disinfection performances of the SBBGR was higher than that of conventional municipal wastewater treatment plants and met the quality criteria suggested by WHO (Escherichia coli<1000 CFU/100 mL) for agricultural reuse. In particular, the biological treatment by SBBGR removed 3.8±0.4 log units of Giardia lamblia, 2.8±0.8 log units of E. coli, 2.5±0.7 log units of total coliforms, 2.0±0.3 log units of Clostridium perfringens, 2.0±0.4 log units of Cryptosporidium parvum and 1.7±0.7 log units of Somatic coliphages. The investigated disinfection processes (UV and peracetic acid) resulted very effective for total coliforms, E. coli and somatic coliphages. In particular, a UV radiation and peracetic acid doses of 40 mJ/cm(2) and 1 mg/L respectively reduced E. coli content in the effluent below the limit for agricultural reuse in Italy (10 CFU/100 mL). Conversely, they were both ineffective on C.perfringens spores. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Activity of disinfectants against foodborne pathogens in suspension and adhered to stainless steel surfaces

    PubMed Central

    Cabeça, Tatiane Karen; Pizzolitto, Antonio Carlos; Pizzolitto, Elisabeth Loshchagin

    2012-01-01

    The purpose of this study was to investigate and compare the efficacy of various disinfectants on planktonic cells and biofilm cells of Listeria monocytogenes, Staphylococcus aureus and Escherichia coli. Numbers of viable biofilm cells decreased after treatment with all tested disinfectants (iodine, biguanide, quaternary ammonium compounds, peracetic acid and sodium hypochlorite). Sodium hypochlorite was the most effective disinfectant against biofilm cells, while biguanide was the least effective. Scanning electron microscopy observations revealed that cells adhered on stainless steel surface after treatment with the disinfectants. No viable planktonic cells were observed after treatment with the same disinfectants. Based on our findings, we concluded that biofilm cells might be more resistant to disinfectants than plancktonic cells. PMID:24031935

  16. The potential for disinfection of separated faecal matter by urea and by peracetic acid for hygienic nutrient recycling.

    PubMed

    Vinnerås, B; Holmqvist, A; Bagge, E; Albihn, A; Jönsson, H

    2003-09-01

    No efficient, reliable, and scale independent disinfection methods for toilet waste are available today for safe recycling of plant nutrients. Therefore, two chemical treatment methods, addition of urea or of PAA (a quaternary mixture of 15% peracetic acid, 15% hydrogen peroxide and 30% acetic acid), were evaluated for disinfection of faecal matter.Degradation of the added urea resulted in 30 g of ammonia nitrogen per kilogram of treated matter and a pH increase to approximately 9.3. This produced an efficient disinfection of E. coli, Enterococcus spp., and Salmonella spp. within 3 weeks (>6log(10) reduction) and a reduction of the chemical resistant Salmonella typhimurium 28b phage, corresponding to a decimal reduction within 7.5 days. No viable Ascaris suum eggs were found after 50 days of treatment. No reduction of spore forming Clostridia spp. was observed. Urea treatment proved to be efficient for disinfection of source separated faecal matter in a scale independent method used for safe recycling of nutrients found in the faecal matter.PAA reduced all of the above indicator organisms within 12 h after application. For this faecal material, with a dry matter content of approximately 10%, an addition of 0.5-1% of PAA (active substance, corresponding to 3.3-6.7% of the Proxitane 15 used) was required before no viable organisms were found in the material. However, this was not tested for the A. suum. No viable spore-forming bacteria or phages were detected. A high rate of bacteria regrowth occurred at 0.15% dosage and 5 days of treatment. PAA is an efficient alternative for disinfection of separated faeces if a rapid treatment is needed.

  17. Application of a high-level peracetic acid disinfection protocol to re-process antibiotic disinfected skin allografts.

    PubMed

    Lomas, R J; Huang, Q; Pegg, D E; Kearney, J N

    2004-01-01

    Skin allografts, derived from cadaveric donors, are widely used for the treatment of burns and ulcers. Prior to use in clinical situations, these allografts are disinfected using a cocktail of antibiotics and then cryopreserved. Unfortunately, this antibiotic disinfection procedure fails to decontaminate a significant proportion and these contaminated grafts can not be used clinically. We have investigated whether it is possible to apply a second, more potent disinfection procedure to these contaminated grafts and effectively to re-process them for clinical use. Cadaveric skin grafts, treated with antibiotics and cryopreserved, were thawed and a peracetic acid (PAA) disinfection protocol applied. The grafts were then preserved in a high concentration of glycerol or propylene glycol, and properties thought to be essential for successful clinical performance assessed. The cytotoxicity of the grafts was assessed using both extract and contact assays; damage to the skin collagen was assessed using a collagenase susceptibility assay and the capacity of the grafts to elicit an inflammatory response in vitro was assessed by quantifying the production of the pro-inflammatory cytokine TNF-alpha by human peripheral blood mononuclear phagocytes. PAA disinfection, in conjunction with either glycerol or propylene glycol preservation, did not render the grafts cytotoxic, pro-inflammatory, or increase their susceptibility to collagenase digestion. The rates of penetration of glycerol and propylene glycol into the re-processed skin were comparable to those of fresh skin. This study has demonstrated that PAA disinfection combined with immersion in high concentrations of either glycerol or propylene glycol was an effective method for re-processing contaminated skin allografts, and may justify their clinical use.

  18. Assessment of occupational exposure to gaseous peracetic acid.

    PubMed

    Dugheri, Stefano; Bonari, Alessandro; Pompilio, Ilenia; Colpo, Marco; Montalti, Manfredi; Mucci, Nicola; Arcangeli, Giulio

    2018-02-07

    In order to assess short-term exposure to peracetic acid (PAA) in disinfection processes, the Authors compared 4 industrial hygiene monitoring methods to evaluate their proficiency in measuring airborne PAA concentrations. An active sampling by basic silica gel impregnated with methyl p-tolyl sulfoxide (MTSO), a passive solid phase micro-extraction technique using methyl p-tolyl sulfide (MTS) as on-fiber derivatization reagent, an electrochemical direct-reading PAA monitor, and a novel visual test strip PAA detector doped with 2,2'-azino-bis (3-ethylbenzothiazoline)-6-sulfonate were evaluated and tested over the range of 0.06-16 mg/m3, using dynamically generated PAA air concentrations. The linear regression analysis of linearity and accuracy showed that the 4 methods were suitable for PAA monitoring. Peracetic acid monitoring in several use applications showed that the PAA concentration (1.8 mg/m3) was immediately dangerous to life or health as proposed by the National Institute of Occupational Safety and Health, and was frequently exceeded in wastewater treatment (up to 7.33 mg/m3), and sometimes during food and beverage processes and hospital high-level disinfection operations (up to 6.8 mg/m3). The methods were suitable for the quick assessment of acute exposure in PAA environmental monitoring and can assist in improving safety and air quality in the workplace where this disinfectant is used. These monitoring methods allowed the evaluation of changes to work out practices to reduce PAA vapor concentrations during the operations when workers are potentially overexposed to this strong antioxidant agent. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  19. The differential effects of heat-shocking on the viability of spores from Bacillus anthracis, Bacillus subtilis, and Clostridium sporogenes after treatment with peracetic acid- and glutaraldehyde-based disinfectants.

    PubMed

    March, Jordon K; Pratt, Michael D; Lowe, Chinn-Woan; Cohen, Marissa N; Satterfield, Benjamin A; Schaalje, Bruce; O'Neill, Kim L; Robison, Richard A

    2015-10-01

    This study investigated (1) the susceptibility of Bacillus anthracis (Ames strain), Bacillus subtilis (ATCC 19659), and Clostridium sporogenes (ATCC 3584) spores to commercially available peracetic acid (PAA)- and glutaraldehyde (GA)-based disinfectants, (2) the effects that heat-shocking spores after treatment with these disinfectants has on spore recovery, and (3) the timing of heat-shocking after disinfectant treatment that promotes the optimal recovery of spores deposited on carriers. Suspension tests were used to obtain inactivation kinetics for the disinfectants against three spore types. The effects of heat-shocking spores after disinfectant treatment were also determined. Generalized linear mixed models were used to estimate 6-log reduction times for each spore type, disinfectant, and heat treatment combination. Reduction times were compared statistically using the delta method. Carrier tests were performed according to AOAC Official Method 966.04 and a modified version that employed immediate heat-shocking after disinfectant treatment. Carrier test results were analyzed using Fisher's exact test. PAA-based disinfectants had significantly shorter 6-log reduction times than the GA-based disinfectant. Heat-shocking B. anthracis spores after PAA treatment resulted in significantly shorter 6-log reduction times. Conversely, heat-shocking B. subtilis spores after PAA treatment resulted in significantly longer 6-log reduction times. Significant interactions were also observed between spore type, disinfectant, and heat treatment combinations. Immediately heat-shocking spore carriers after disinfectant treatment produced greater spore recovery. Sporicidal activities of disinfectants were not consistent across spore species. The effects of heat-shocking spores after disinfectant treatment were dependent on both disinfectant and spore species. Caution must be used when extrapolating sporicidal data of disinfectants from one spore species to another. Heat-shocking provides a more accurate picture of spore survival for only some disinfectant/spore combinations. Collaborative studies should be conducted to further examine a revision of AOAC Official Method 966.04 relative to heat-shocking. © 2015 The Authors. MicrobiologyOpen published by John Wiley & Sons Ltd.

  20. Stability of antimicrobial activity of peracetic acid solutions used in the final disinfection process.

    PubMed

    Costa, Solange Alves da Silva; Paula, Olívia Ferreira Pereira de; Silva, Célia Regina Gonçalves E; Leão, Mariella Vieira Pereira; Santos, Silvana Soléo Ferreira dos

    2015-01-01

    The instruments and materials used in health establishments are frequently exposed to microorganism contamination, and chemical products are used before sterilization to reduce occupational infection. We evaluated the antimicrobial effectiveness, physical stability, and corrosiveness of two commercial formulations of peracetic acid on experimentally contaminated specimens. Stainless steel specimens were contaminated with Staphylococcus aureus, Escherichia coli, Candida albicans, blood, and saliva and then immersed in a ready peracetic acid solution: 2% Sekusept Aktiv (SA) or 0.25% Proxitane Alpha (PA), for different times. Then, washes of these instruments were plated in culture medium and colony-forming units counted. This procedure was repeated six times per day over 24 non-consecutive days. The corrosion capacity was assessed with the mass loss test, and the concentration of peracetic acid and pH of the solutions were measured with indicator tapes. Both SA and PA significantly eliminated microorganisms; however, the SA solution was stable for only 4 days, whereas PA remained stable throughout the experiment. The concentration of peracetic acid in the SA solutions decreased over time until the chemical was undetectable, although the pH remained at 5. The PA solution had a concentration of 500-400 mg/L and a pH of 2-3. Neither formulation induced corrosion and both reduced the number of microorganisms (p = 0.0001). However, the differences observed in the performance of each product highlight the necessity of establishing a protocol for optimizing the use of each one.

  1. Efficiency of peracetic acid in inactivating bacteria, viruses, and spores in water determined with ATP bioluminescence, quantitative PCR, and culture-based methods.

    PubMed

    Park, Eunyoung; Lee, Cheonghoon; Bisesi, Michael; Lee, Jiyoung

    2014-03-01

    The disinfection efficiency of peracetic acid (PAA) was investigated on three microbial types using three different methods (filtration-based ATP (adenosine-triphosphate) bioluminescence, quantitative polymerase chain reaction (qPCR), culture-based method). Fecal indicator bacteria (Enterococcus faecium), virus indicator (male-specific (F(+)) coliphages (coliphages)), and protozoa disinfection surrogate (Bacillus subtilis spores (spores)) were tested. The mode of action for spore disinfection was visualized using scanning electron microscopy. The results indicated that PAA concentrations of 5 ppm (contact time: 5 min), 50 ppm (10 min), and 3,000 ppm (5 min) were needed to achieve 3-log reduction of E. faecium, coliphages, and spores, respectively. Scanning electron microscopy observation showed that PAA targets the external layers of spores. The lower reduction rates of tested microbes measured with qPCR suggest that qPCR may overestimate the surviving microbes. Collectively, PAA showed broad disinfection efficiency (susceptibility: E. faecium > coliphages > spores). For E. faecium and spores, ATP bioluminescence was substantially faster (∼5 min) than culture-based method (>24 h) and qPCR (2-3 h). This study suggests PAA as an effective alternative to inactivate broad types of microbial contaminants in water. Together with the use of rapid detection methods, this approach can be useful for urgent situations when timely response is needed for ensuring water quality.

  2. Peracetic acid is an optimal disinfectant for fish-microalgae integrated multi-trophic aquaculture systems

    USDA-ARS?s Scientific Manuscript database

    Integrated multi-trophic aquaculture is a promising direction for the sustainable development of aquaculture. Instead of releasing nutrition-rich waste to the environment or decomposition of nutrients via the biofilter, the ‘waste’ from fish can be recycled to produce byproducts (e.g., algae, plants...

  3. The resistance of Bacillus atrophaeus spores to the bactericidal activity of peracetic acid is influenced by both the nature of the solid substrates and the mode of contamination.

    PubMed

    Grand, I; Bellon-Fontaine, M-N; Herry, J-M; Hilaire, D; Moriconi, F-X; Naïtali, M

    2010-11-01

    To evaluate the impact of the mode of contamination in relation with the nature of solid substrates on the resistance of spores of Bacillus atrophaeus -selected as surrogates of Bacillus anthracis- to a disinfectant, peracetic acid. Six materials confronted in urban and military environments were selected for their different structural and physicochemical properties. In parallel, two modes of contamination were examined, i.e. deposition and immersion. Deposition was used to simulate contamination by an aerosol and immersion by an extended contact with liquids. A pronounced difference in the biocontamination levels and spatial organization of spores was observed depending on the mode of contamination and the nature of the solid substrate considered, with consequences on decontamination. Contamination by immersion led to lower efficiency of peracetic acid decontamination than contamination by deposition. Infiltration of spores into porous materials after immersion is one reason. In contrast, the deposition mode aggregates cells at the surface of materials, explaining the similar disinfecting behaviour of porous and nonporous substrates when considering this inoculation route. The inoculation route was shown to be as influential a parameter as material characteristics (porosity and wettability) for decontamination efficacy. These results provide comparative information for the decontamination of B. atrophaeus spores in function of the mode of contamination and the nature of solid substrates. Journal of Applied Microbiology © 2010 The Society for Applied Microbiology. No claim to French government works.

  4. Disinfection of an advanced primary effluent using peracetic acid or ultraviolet radiation for its reuse in public services.

    PubMed

    Julio, Flores R; Hilario, Terres-Peña; Mabel, Vaca M; Raymundo, López C; Arturo, Lizardi-Ramos; Ma Neftalí, Rojas-Valencia

    2015-03-01

    The disinfection of a continuous flow of an effluent from an advanced primary treatment (coagulation-flocculation-sedimentation) with or without posterior filtration, using either peracetic acid (PAA) or ultraviolet (UV) radiation was studied. We aimed to obtain bacteriological quality to comply with the microbiological standard established in the Mexican regulations for treated wastewater reuse (NOM-003-SEMARNAT-1997), i.e., less than 240 MPN (most probable number) FC/100 mL. The concentrations of PAA were 10, 15, and 20 mg/L, with contact times of 10, and 15 min. Fecal coliforms (FC) inactivation ranged from 0.93 up to 6.4 log units, and in all cases it reached the limits set by the mentioned regulation. Water quality influenced the PAA disinfection effectiveness. An efficiency of 91% was achieved for the unfiltered effluent, as compared to 99% when wastewater was filtered. UV radiation was applied to wastewater flows of 21, 30 and 39 L/min, with dosages from 1 to 6 mJ/cm². This treatment did not achieve the bacteriological quality required for treated wastewater reuse, since the best inactivation of FC was 1.62 log units, for a flow of 21 L/min of filtered wastewater and a UV dosage of 5.6 mJ/cm².

  5. Effect of sodium hypochlorite and peracetic acid on the surface roughness of acrylic resin polymerized by heated water for short and long cycles.

    PubMed

    Sczepanski, Felipe; Sczepanski, Claudia Roberta Brunnquell; Berger, Sandrine Bittencourt; Consani, Rafael Leonardo Xediek; Gonini-Júnior, Alcides; Guiraldo, Ricardo Danil

    2014-10-01

    To evaluate the surface roughness of acrylic resin submitted to chemical disinfection via 1% sodium hypochlorite (NaClO) or 1% peracetic acid (C2H4O3). The disc-shaped resin specimens (30 mm diameter ×4 mm height) were polymerized by heated water using two cycles (short cycle: 1 h at 74°C and 30 min at 100°C; conventional long cycle: 9 h at 74°C). The release of substances by these specimens in water solution was also quantified. Specimens were fabricated, divided into four groups (n = 10) depending on the polymerization time and disinfectant. After polishing, the specimens were stored in distilled deionized water. Specimens were immersed in 1% NaClO or 1% C2H4O3 for 30 min, and then were immersed in distilled deionized water for 20 min. The release of C2H4O3 and NaClO was measured via visual colorimetric analysis. Roughness was measured before and after disinfection. Roughness data were subjected to two-way ANOVA and Tukey's test. There was no interaction between polymerization time and disinfectant in influencing the average surface roughness (Ra, P = 0.957). Considering these factors independently, there were significant differences between short and conventional long cycles (P = 0.012), but no significant difference between the disinfectants hypochlorite and C2H4O3 (P = 0.366). Visual colorimetric analysis did not detect release of substances. It was concluded that there was the difference in surface roughness between short and conventional long cycles, and disinfection at acrylic resins polymerized by heated water using a short cycle modified the properties of roughness.

  6. Effect of sodium hypochlorite and peracetic acid on the surface roughness of acrylic resin polymerized by heated water for short and long cycles

    PubMed Central

    Sczepanski, Felipe; Sczepanski, Claudia Roberta Brunnquell; Berger, Sandrine Bittencourt; Consani, Rafael Leonardo Xediek; Gonini-Júnior, Alcides; Guiraldo, Ricardo Danil

    2014-01-01

    Objective: To evaluate the surface roughness of acrylic resin submitted to chemical disinfection via 1% sodium hypochlorite (NaClO) or 1% peracetic acid (C2H4O3). Materials and Methods: The disc-shaped resin specimens (30 mm diameter ×4 mm height) were polymerized by heated water using two cycles (short cycle: 1 h at 74°C and 30 min at 100°C; conventional long cycle: 9 h at 74°C). The release of substances by these specimens in water solution was also quantified. Specimens were fabricated, divided into four groups (n = 10) depending on the polymerization time and disinfectant. After polishing, the specimens were stored in distilled deionized water. Specimens were immersed in 1% NaClO or 1% C2H4O3 for 30 min, and then were immersed in distilled deionized water for 20 min. The release of C2H4O3 and NaClO was measured via visual colorimetric analysis. Roughness was measured before and after disinfection. Roughness data were subjected to two-way ANOVA and Tukey's test. Results: There was no interaction between polymerization time and disinfectant in influencing the average surface roughness (Ra, P = 0.957). Considering these factors independently, there were significant differences between short and conventional long cycles (P = 0.012), but no significant difference between the disinfectants hypochlorite and C2H4O3 (P = 0.366). Visual colorimetric analysis did not detect release of substances. Conclusion: It was concluded that there was the difference in surface roughness between short and conventional long cycles, and disinfection at acrylic resins polymerized by heated water using a short cycle modified the properties of roughness. PMID:25512737

  7. Evaluation of Combined Peracetic acid and UV treatment for ...

    EPA Pesticide Factsheets

    The current study evaluates the effectiveness of the combined application of Peracetic acid and ultraviolet radiation as alternative disinfectant agents to the traditional chlorination of wastewater effluents. Various pathogens (E. coli, enterococci and fecal coliforms) were evaluated in the study. Four experiments were conducted using low to high PAA levels and UV dosages. E. coli and enterococci were resistant to low to moderate PAA dosage (0.5- 1 mg/L). These microbes can be removed effectively at high PAA dosage (2.5 mg/L) with 30 min contact time. Fecal coliforms were completely inactivated even at a low PAA dose of 0.7 mg/L. E. coli was more susceptible to UV disinfection than enterococci at low UV dosages. Enterococci required at least 40 mJ/cm2 for 2.5 log inactivation. In combined PAA + UV treatment, low UV intensities between 7 – 40 mJ/cm2 showed poor disinfection performance at a low PAA concentration of 1.5 mg/L. High UV intensities of 120 and 60 mJ/cm2 inactivated all the pathogens to below detection levels even at low to moderate PAA (0.7 mg/L and 1 mg/L) pretreatment concentration. Combined PAA + UV treatment at 1 mg/L (for 15 and 30 min contact time) + 120 and 60 mJ/cm2 did not show any regrowth of microbes, whereas PAA only disinfection with 15 min contact time showed regrowth of enterococci and fecal coliforms. UV only disinfection showed E. coli regrowth. • This pilot scale study was designed for providing necessary parameter optimization

  8. Use of Copper Sulfate and a New Disinfectant called Peracetic Acid in Aquaculture

    USDA-ARS?s Scientific Manuscript database

    Copper sulfate treatments are currently used for water treatments to control algae and snails, but also to control parasites (mainly Ich) on fish and fungus (Saprolegnia) on fish eggs. This compound has also been used in the past to control columnaris on fish, although antibiotics are the common tr...

  9. Effects of semi-continous peracetic acid dosing on rainbow trout Oncorhynchus mykiss performance, water quality, and off-flavor compounds in recirculation aquaculture systems

    USDA-ARS?s Scientific Manuscript database

    Water clarifying and disinfection techniques such as ozonation and ultraviolet irradiation are commonly used in recirculation aquaculture systems (RAS); however, the capital and operating costs of these technologies are expensive. Cost-effective treatment options that maintain fish health and simult...

  10. Disinfection of tertiary wastewater effluent prior to river discharge using peracetic acid; treatment efficiency and results on by-products formed in full scale tests.

    PubMed

    Pedersen, Per Overgaard; Brodersen, Erling; Cecil, David

    2013-01-01

    This is an investigation of chemical disinfection, with peracetic acid (PAA), in a tertiary sand filter at a full scale activated sludge plant with nitrification/denitrification and P-removal. The reduction efficiency of Escherichia coli and intestinal enterococci in the sand filter is reported. E. coli log reductions of between 0.4 and 2.2 were found with contact times from 6 to 37 min and with dosing from 0 to 4.8 mg L(-1). The average log reduction was 1.3. The decomposition products, bromophenols, chlorophenols and formaldehyde and residual H2O2 were measured before and after the sand filter. The residual H2O2 concentration in the effluent was critical at short contact times and high dosages of PAA due to the discharge limit of 25 μg L(-1). The other three products could not be detected at 0.1 μg L(-1) levels. The chemical cost of PAA dosing is estimated to be 0.039 US$ m(-3) treated wastewater.

  11. Toxicity evaluation of surface water treated with different disinfectants in HepG2 cells.

    PubMed

    Marabini, Laura; Frigerio, Silvia; Chiesara, Enzo; Radice, Sonia

    2006-01-01

    It is well known that water disinfection through chlorination causes the formation of a mixture of disinfection by-products (DBPs), many of which are genotoxic and carcinogenic. To demonstrate the formation of such compounds, a pilot water plant supplied with water from Lake Trasimeno was set up at the waterworks of Castiglione del Lago (PG, Italy). The disinfectants, continuously added to pre-filtered lake water flowing into three different basins, were sodium hypochlorite, chlorine dioxide and peracetic acid, an alternative disinfectant used until now for disinfecting waste waters, but not yet studied for a possible use in drinking water treatment. The aim of this study was to evaluate the formation during the disinfection processes of some toxic compounds that could explain the genotoxic effects of drinking waters. Differently treated waters were concentrated by solid-phase adsorption on silica C(18) columns and toxicity was assessed in a line of human hepatoma cells (HepG2), a metabolically competent cellular line very useful for human risk evaluation. The seasonal variability of the physical-chemical water characteristics (AOX, UV 254 nm, potential formation of THM, pH and temperature) made indispensable experimentation with water samples taken during the various seasons. Autumn waters cause greater toxicity compared to those of other seasons, in particular dilution of the concentrate at 0.5l equivalent of disinfected waters with chlorine dioxide and peracetic acid causes a 55% reduction in cellular vitality while the cellular vitality is over 80% with the all other water concentrates. Moreover it is very interesting underline that non-cytotoxic quantities of the autumnal water concentrates cause, after 2h treatment, a decrease in GSH and a statistically significant increase in oxygen radicals, while after prolonged treatment (24h) cause a GSH increase, without variations in the oxygen radical content. This phenomenon could be interpreted as the cellular adaptation response to an initial oxidative stress.

  12. Evaluation and control of microbial and chemical contamination in dialysis water plants of Italian nephrology wards.

    PubMed

    Totaro, M; Casini, B; Valentini, P; Miccoli, M; Giorgi, S; Porretta, A; Privitera, G; Lopalco, P L; Baggiani, A

    2017-10-01

    Patients receiving haemodialysis are exposed to a large volume of dialysis fluid. The Italian Society of Nephrology (ISN) has published guidelines and microbial quality standards on dialysis water (DW) and solutions to ensure patient safety. To identify microbial and chemical hazards, and evaluate the quality of disinfection treatment in DW plants. In 2015 and 2016, water networks and DW plants (closed loop and online monitors) of nine dialysis wards of Italian hospitals, hosting 162 dialysis beds overall, were sampled on a monthly basis to determine the parameters provided by ISN guidelines. Chlorinated drinking water was desalinated by reverse osmosis and distributed to the closed loop which feeds all online monitors. Disinfection with peracetic acid was performed in all DW plants on a monthly basis. Over the 24-month study period, seven out of nine DW plants (78%) recorded negative results for all investigated parameters. Closed loop contamination with Burkholderia cepacia was detected in a DW plant from January 2015 to March 2015. Pseudomonas aeruginosa was isolated from March 2016 to May 2016 in the closed loop of another DW plant. These microbial contaminations were eradicated by shock disinfection with sodium hypochlorite and peracetic acid, followed by water flushing. These results highlight the importance of chemical and physical methods of DW disinfection. The maintenance of control measures in water plants hosted in dialysis wards ensures a microbial risk reduction for all dialysis patients. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  13. Loss reduction in a rainbow trout recirculating aquaculture systems (RAS) by periodical disinfection with peracetic acid (PAA)

    USDA-ARS?s Scientific Manuscript database

    In a research rainbow trout (Oncorhynchus mykiss) RAS, two different sized raceways were operated with one common biofilter unit. The larger raceway was stocked with food fish, while the smaller raceway was stocked with juvenile trout. After removal of the food fish, juveniles were moved into free s...

  14. Evaluation of AISI Type 304 stainless steel as a suitable surface material for evaluating the efficacy of peracetic acid-based disinfectants against Clostridium difficile spores.

    PubMed

    Black, Elaine; Owens, Krista; Staub, Richard; Li, Junzhong; Mills, Kristen; Valenstein, Justin; Hilgren, John

    2017-01-01

    Disinfectants play an important role in controlling microbial contamination on hard surfaces in hospitals. The effectiveness of disinfectants in real life can be predicted by laboratory tests that measure killing of microbes on carriers. The modified Quantitative Disk Carrier Test (QCT-2) is a standard laboratory method that employs American Iron and Steel Institute (AISI) Type 430 stainless steel carriers to measure hospital disinfectant efficacy against Clostridium difficile spores. The formation of a rust-colored precipitate was observed on Type 430 carriers when testing a peracetic acid (PAA)-based disinfectant with the QCT-2 method. It was hypothesized that the precipitate was indicative of corrosion of the Type 430 carrier, and that corrosion could impact efficacy results. The objective of this study was to compare the suitability of AISI Type 430 to Type 304 stainless steel carriers for evaluating PAA-based disinfectants using the QCT-2 method. Type 304 is more corrosion-resistant than Type 430, is ubiquitous in healthcare environments, and is used in other standard methods. Suitability of the carriers was evaluated by comparing their impacts on efficacy results and PAA degradation rates. In efficacy tests with 1376 ppm PAA, reductions of C. difficile spores after 5, 7 and 10 minutes on Type 430 carriers were at least about 1.5 log10 lower than reductions on Type 304 carriers. In conditions simulating a QCT-2 test, PAA concentration with Type 430 carriers was reduced by approximately 80% in 10 minutes, whereas PAA concentration in the presence of Type 304 carriers remained stable. Elemental analyses of residues on each carrier type after efficacy testing were indicative of corrosion on the Type 430 carrier. Use of Type 430 stainless steel carriers for measuring the efficacy of PAA-based disinfectants should be avoided as it can lead to an underestimation of real life sporicidal efficacy. Type 304 stainless steel carriers are recommended as a suitable alternative.

  15. Evaluation of AISI Type 304 stainless steel as a suitable surface material for evaluating the efficacy of peracetic acid-based disinfectants against Clostridium difficile spores

    PubMed Central

    Owens, Krista; Staub, Richard; Li, Junzhong; Mills, Kristen; Valenstein, Justin; Hilgren, John

    2017-01-01

    Disinfectants play an important role in controlling microbial contamination on hard surfaces in hospitals. The effectiveness of disinfectants in real life can be predicted by laboratory tests that measure killing of microbes on carriers. The modified Quantitative Disk Carrier Test (QCT-2) is a standard laboratory method that employs American Iron and Steel Institute (AISI) Type 430 stainless steel carriers to measure hospital disinfectant efficacy against Clostridium difficile spores. The formation of a rust-colored precipitate was observed on Type 430 carriers when testing a peracetic acid (PAA)-based disinfectant with the QCT-2 method. It was hypothesized that the precipitate was indicative of corrosion of the Type 430 carrier, and that corrosion could impact efficacy results. The objective of this study was to compare the suitability of AISI Type 430 to Type 304 stainless steel carriers for evaluating PAA-based disinfectants using the QCT-2 method. Type 304 is more corrosion-resistant than Type 430, is ubiquitous in healthcare environments, and is used in other standard methods. Suitability of the carriers was evaluated by comparing their impacts on efficacy results and PAA degradation rates. In efficacy tests with 1376 ppm PAA, reductions of C. difficile spores after 5, 7 and 10 minutes on Type 430 carriers were at least about 1.5 log10 lower than reductions on Type 304 carriers. In conditions simulating a QCT-2 test, PAA concentration with Type 430 carriers was reduced by approximately 80% in 10 minutes, whereas PAA concentration in the presence of Type 304 carriers remained stable. Elemental analyses of residues on each carrier type after efficacy testing were indicative of corrosion on the Type 430 carrier. Use of Type 430 stainless steel carriers for measuring the efficacy of PAA-based disinfectants should be avoided as it can lead to an underestimation of real life sporicidal efficacy. Type 304 stainless steel carriers are recommended as a suitable alternative. PMID:29065168

  16. Morphological bactericidal fast-acting effects of peracetic acid, a high-level disinfectant, against Staphylococcus aureus and Pseudomonas aeruginosa biofilms in tubing.

    PubMed

    Chino, T; Nukui, Y; Morishita, Y; Moriya, K

    2017-01-01

    The bactericidal effect of disinfectants against biofilms is essential to reduce potential endoscopy-related infections caused by contamination. Here, we investigated the bactericidal effect of a high-level disinfectant, peracetic acid (PAA), against Staphylococcus aureus and Pseudomonas aeruginosa biofilm models in vitro. S. aureus and P. aeruginosa biofilms were cultured at 35 °C for 7 days with catheter tubes. The following high-level disinfectants (HLDs) were tested: 0.3% PAA, 0.55% ortho-phthalaldehyde (OPA), and 2.0% alkaline-buffered glutaraldehyde (GA). Biofilms were exposed to these agents for 1-60 min and observed after 5 min and 30 min by transmission and scanning electron microscopy. A Student's t test was performed to compare the exposure time required for bactericidal effectiveness of the disinfectants. PAA and GA were active within 1 min and 5 min, respectively, against S. aureus and P. aeruginosa biofilms. OPA took longer than 10 min and 30 min to act against S. aureus and P. aeruginosa biofilms, respectively ( p  < 0.01). Treatment with PAA elicited changes in cell shape after 5 min and structural damage after 30 min. Amongst the HLDs investigated, PAA elicited the most rapid bactericidal effects against both biofilms. Additionally, treatment with PAA induced morphological alterations in the in vitro biofilm models, suggesting that PAA exerts fast-acting bactericidal effects against biofilms associated with endoscopy-related infections. These findings indicate that the exposure time for bactericidal effectiveness of HLDs for endoscope reprocessing in healthcare settings should be reconsidered.

  17. Possible overestimation of surface disinfection efficiency by assessment methods based on liquid sampling procedures as demonstrated by in situ quantification of spore viability.

    PubMed

    Grand, I; Bellon-Fontaine, M-N; Herry, J-M; Hilaire, D; Moriconi, F-X; Naïtali, M

    2011-09-01

    The standard test methods used to assess the efficiency of a disinfectant applied to surfaces are often based on counting the microbial survivors sampled in a liquid, but total cell removal from surfaces is seldom achieved. One might therefore wonder whether evaluations of microbial survivors in liquid-sampled cells are representative of the levels of survivors in whole populations. The present study was thus designed to determine the "damaged/undamaged" status induced by a peracetic acid disinfection for Bacillus atrophaeus spores deposited on glass coupons directly on this substrate and to compare it to the status of spores collected in liquid by a sampling procedure. The method utilized to assess the viability of both surface-associated and liquid-sampled spores included fluorescence labeling with a combination of Syto 61 and Chemchrome V6 dyes and quantifications by analyzing the images acquired by confocal laser scanning microscopy. The principal result of the study was that the viability of spores sampled in the liquid was found to be poorer than that of surface-associated spores. For example, after 2 min of peracetic acid disinfection, less than 17% ± 5% of viable cells were detected among liquid-sampled cells compared to 79% ± 5% or 47% ± 4%, respectively, when the viability was evaluated on the surface after or without the sampling procedure. Moreover, assessments of the survivors collected in the liquid phase, evaluated using the microscopic method and standard plate counts, were well correlated. Evaluations based on the determination of survivors among the liquid-sampled cells can thus overestimate the efficiency of surface disinfection procedures.

  18. Possible Overestimation of Surface Disinfection Efficiency by Assessment Methods Based on Liquid Sampling Procedures as Demonstrated by In Situ Quantification of Spore Viability ▿

    PubMed Central

    Grand, I.; Bellon-Fontaine, M.-N.; Herry, J.-M.; Hilaire, D.; Moriconi, F.-X.; Naïtali, M.

    2011-01-01

    The standard test methods used to assess the efficiency of a disinfectant applied to surfaces are often based on counting the microbial survivors sampled in a liquid, but total cell removal from surfaces is seldom achieved. One might therefore wonder whether evaluations of microbial survivors in liquid-sampled cells are representative of the levels of survivors in whole populations. The present study was thus designed to determine the “damaged/undamaged” status induced by a peracetic acid disinfection for Bacillus atrophaeus spores deposited on glass coupons directly on this substrate and to compare it to the status of spores collected in liquid by a sampling procedure. The method utilized to assess the viability of both surface-associated and liquid-sampled spores included fluorescence labeling with a combination of Syto 61 and Chemchrome V6 dyes and quantifications by analyzing the images acquired by confocal laser scanning microscopy. The principal result of the study was that the viability of spores sampled in the liquid was found to be poorer than that of surface-associated spores. For example, after 2 min of peracetic acid disinfection, less than 17% ± 5% of viable cells were detected among liquid-sampled cells compared to 79% ± 5% or 47% ± 4%, respectively, when the viability was evaluated on the surface after or without the sampling procedure. Moreover, assessments of the survivors collected in the liquid phase, evaluated using the microscopic method and standard plate counts, were well correlated. Evaluations based on the determination of survivors among the liquid-sampled cells can thus overestimate the efficiency of surface disinfection procedures. PMID:21742922

  19. Disinfection methods for spores of Bacillus atrophaeus, B. anthracis, Clostridium tetani, C. botulinum and C. difficile.

    PubMed

    Oie, Shigeharu; Obayashi, Akiko; Yamasaki, Hirofumi; Furukawa, Hiroyuki; Kenri, Tsuyoshi; Takahashi, Motohide; Kawamoto, Keiko; Makino, Sou-ichi

    2011-01-01

    To evaluate disinfection methods for environments contaminated with bioterrorism-associated microorganism (Bacillus anthracis), we performed the following experiments. First, the sporicidal effects of sodium hypochlorite on spores of five bacterial species were evaluated. Bacillus atrophaeus was the most resistant to hypochlorite, followed in order by B. anthracis, Clostridium botulinum and Clostridium tetani, and Clostridium difficile. Subsequently, using B. atrophaeus spores that were the most resistant to hypochlorite, the sporicidal effects of hypochlorite at lower pH by adding vinegar were evaluated. Hypochlorite containing vinegar had far more marked sporicidal effects than hypochlorite alone. Cleaning with 0.5% (5000 ppm) hypochlorite containing vinegar inactivated B. atrophaeus spores attached to vinyl chloride and plywood plates within 15 s, while that not containing vinegar did not inactivate spores attached to cement or plywood plates even after 1 h. Therefore, the surfaces of cement or plywood plates were covered with gauze soaked in 0.5% hypochlorite containing vinegar, and the sporicidal effects were evaluated. B. atrophaeus spores attached to plywood plates were not inactivated even after 6 h, but those attached to cement plates were inactivated within 5 min. On the other hand, covering the surfaces of plywood plates with gauze soaked in 0.3% peracetic acid and gauze soaked in 2% glutaral inactivated B. atrophaeus spores within 5 min and 6 h, respectively. These results suggest that hypochlorite containing vinegar is effective for disinfecting vinyl chloride, tile, and cement plates contaminated with B. anthracis, and peracetic acid is effective for disinfecting plywood plates contaminated with such microorganism.

  20. Comparative biomechanical and microstructural analysis of native versus peracetic acid-ethanol treated cancellous bone graft.

    PubMed

    Rauh, Juliane; Despang, Florian; Baas, Jorgen; Liebers, Cornelia; Pruss, Axel; Gelinsky, Michael; Günther, Klaus-Peter; Stiehler, Maik

    2014-01-01

    Bone transplantation is frequently used for the treatment of large osseous defects. The availability of autologous bone grafts as the current biological gold standard is limited and there is a risk of donor site morbidity. Allogenic bone grafts are an appealing alternative, but disinfection should be considered to reduce transmission of infection disorders. Peracetic acid-ethanol (PE) treatment has been proven reliable and effective for disinfection of human bone allografts. The purpose of this study was to evaluate the effects of PE treatment on the biomechanical properties and microstructure of cancellous bone grafts (CBG). Forty-eight human CBG cylinders were either treated by PE or frozen at -20 °C and subjected to compression testing and histological and scanning electron microscopy (SEM) analysis. The levels of compressive strength, stiffness (Young's modulus), and fracture energy were significantly decreased upon PE treatment by 54%, 59%, and 36%, respectively. Furthermore, PE-treated CBG demonstrated a 42% increase in ultimate strain. SEM revealed a modified microstructure of CBG with an exposed collagen fiber network after PE treatment. We conclude that the observed reduced compressive strength and reduced stiffness may be beneficial during tissue remodeling thereby explaining the excellent clinical performance of PE-treated CBG.

  1. Carrier tests to assess the effective sporicidal concentration of a liquid chemical disinfectant for a sanitization program.

    PubMed

    Ceccanti, Stefano; Giampieri, Simona; Burgalassi, Susi

    2011-01-01

    The aim of the present investigation was to evaluate the microbial efficacy against highly resistant bacterial spores on different substrates using the lowest effective concentration of a market liquid sporicide based on peracetic acid. The validation was carried out following modified European regulatory agencies procedures or test methods and USP guidelines, employing carriers of materials usually treated with the sporicidal solution and present in grade A cleanrooms and spores of four different microorganisms: Bacillus subtilis and Clostridium sporogenes, both from the ATCC collection, and Bacillus cereus and Bacillus sphaericus as environmental isolates. A statistical evaluation of data was made to estimate the variance for different study conditions. The experiments highlighted that 70% suitable dilution of the ready-to-use peracetic acid solution was effective in both clean and dirty conditions, showing at least 2 log spore reduction after treatment. To obtain effective sporicidal action on the surfaces in cleanrooms it is sufficient to use a sporicidal solution with a ready-to-use concentration of 70% while ensuring a contact time of 10 min. In any case, the reduction of sporicide concentration ensures a high degree of disinfection and provides a consumption savings. Wide-spectrum disinfectants are used in the pharmaceutical industry for the decontamination of work surfaces and equipment, but these products have some degree of toxicity for operators. This work arises from the needs of pharmaceutical companies to find the lowest effective concentration of sanitizers in order to reduce toxicity to personnel. The sanitizer used in the study was a market liquid sporicide based on peracetic acid. When we started our work no similar studies were reported in the literature, so we took European regulatory agencies and USP guidelines as a starting point, employing carriers of hard, non-porous materials usually treated with the sporicidal solution and present in sterile rooms and spores of four different microorganisms. The experiments highlighted that it is sufficient to use a 70% sporicidal solution concentration with a contact time of 10 min to reduce the number of spores to acceptable values for medicinal production. The reduction of sporicide concentration both ensures a high degree of disinfection and provides a safer working environment and consumption savings.

  2. Evaluation of two disinfection/sterilization methods on silicon rubber-based composite finishing instruments.

    PubMed

    Lacerda, Vánia A; Pereira, Leandro O; Hirata JUNIOR, Raphael; Perez, Cesar R

    2015-12-01

    To evaluate the effectiveness of disinfection/sterilization methods and their effects on polishing capacity, micomorphology, and composition of two different composite fiishing and polishing instruments. Two brands of finishing and polishing instruments (Jiffy and Optimize), were analyzed. For the antimicrobial test, 60 points (30 of each brand) were used for polishing composite restorations and submitted to three different groups of disinfection/sterilization methods: none (control), autoclaving, and immersion in peracetic acid for 60 minutes. The in vitro tests were performed to evaluate the polishing performance on resin composite disks (Amelogen) using a 3D scanner (Talyscan) and to evaluate the effects on the points' surface composition (XRF) and micromorphology (MEV) after completing a polishing and sterilizing routine five times. Both sterilization/disinfection methods were efficient against oral cultivable organisms and no deleterious modification was observed to point surface.

  3. Differential Biofilm Formation and Chemical Disinfection Resistance of Sessile Cells of Listeria monocytogenes Strains under Monospecies and Dual-Species (with Salmonella enterica) Conditions

    PubMed Central

    Kostaki, Maria; Chorianopoulos, Nikos; Braxou, Elli; Nychas, George-John

    2012-01-01

    This study aimed to investigate the possible influence of bacterial intra- and interspecies interactions on the ability of Listeria monocytogenes and Salmonella enterica to develop mixed-culture biofilms on an abiotic substratum, as well as on the subsequent resistance of sessile cells to chemical disinfection. Initially, three strains from each species were selected and left to attach and form biofilms on stainless steel (SS) coupons incubated at 15°C for 144 h, in periodically renewable tryptone soy broth (TSB), under either monoculture or mixed-culture (mono-/dual-species) conditions. Following biofilm formation, mixed-culture sessile communities were subjected to 6-min disinfection treatments with (i) benzalkonium chloride (50 ppm), (ii) sodium hypochlorite (10 ppm), (iii) peracetic acid (10 ppm), and (iv) a mixture of hydrogen peroxide (5 ppm) and peracetic acid (5 ppm). Results revealed that both species reached similar biofilm counts (ca. 105 CFU cm−2) and that, in general, interspecies interactions did not have any significant effect either on the biofilm-forming ability (as this was assessed by agar plating enumeration of the mechanically detached biofilm bacteria) or on the antimicrobial resistance of each individual species. Interestingly, pulsed-field gel electrophoresis (PFGE) analysis clearly showed that the three L. monocytogenes strains did not contribute at the same level either to the formation of mixed-culture sessile communities (mono-/dual species) or to their antimicrobial recalcitrance. Additionally, the simultaneous existence inside the biofilm structure of S. enterica cells seemed to influence the occurrence and resistance pattern of L. monocytogenes strains. In sum, this study highlights the impact of microbial interactions taking place inside a mixed-culture sessile community on both its population dynamics and disinfection resistance. PMID:22307304

  4. Resistance of Pseudomonas aeruginosa to liquid disinfectants on contaminated surfaces before formation of biofilms.

    PubMed

    Sagripanti, J L; Bonifacino, A

    2000-01-01

    A comparison was made of the effectiveness of popular disinfectants (Cavicide, Cidexplus, Clorox, Exspor, Lysol, Renalin, and Wavicide) under conditions prescribed for disinfection in the respective product labels on Pseudomonas aeruginosa either in suspension or deposited onto surfaces of metallic or polymeric plastic devices. The testing also included 7 nonformulated germicidal agents (glutaraldehyde, formaldehyde, peracetic acid, hydrogen peroxide, sodium hypochlorite, phenol, and cupric ascorbate) commonly used in disinfection and decontamination. Results showed that P. aeruginosa is on average 300-fold more resistant when present on contaminated surfaces than in suspension. This increase in resistance agrees with results reported in studies of biofilms, but unexpectedly, it precedes biofilm formation. The surface to which bacteria are attached can influence the effectiveness of disinfectants. Viable bacteria attached to devices may require dislodging through more than a one-step method for detection. The data, obtained with a sensitive and quantitative test, suggest that disinfectants are less effective on contaminated surfaces than generally acknowledged.

  5. Peracetic acid oxidation of saline waters in the absence and presence of H ₂O ₂: secondary oxidant and disinfection byproduct formation.

    PubMed

    Shah, Amisha D; Liu, Zheng-Qian; Salhi, Elisabeth; Höfer, Thomas; von Gunten, Urs

    2015-02-03

    Peracetic acid (PAA) is a disinfectant considered for use in ballast water treatment, but its chemical behavior in such systems (i.e., saline waters) is largely unknown. In this study, the reactivity of PAA with halide ions (chloride and bromide) to form secondary oxidants (HOCl, HOBr) was investigated. For the PAA-chloride and PAA-bromide reactions, second-order rate constants of (1.47 ± 0.58) × 10(-5) and 0.24 ± 0.02 M(-1) s(-1) were determined for the formation of HOCl or HOBr, respectively. Hydrogen peroxide (H2O2), which is always present in PAA solutions, reduced HOCl or HOBr to chloride or bromide, respectively. As a consequence, in PAA-treated solutions with [H2O2] > [PAA], the HOBr (HOCl) steady-state concentrations were low with a limited formation of brominated (chlorinated) disinfection byproducts (DBPs). HOI (formed from the PAA-iodide reaction) affected this process because it can react with H2O2 back to iodide. H2O2 is thus consumed in a catalytic cycle and leads to less efficient HOBr scavenging at even low iodide concentrations (<1 μM). In PAA-treated solutions with [H2O2] < [PAA] and high bromide levels, mostly brominated DBPs are formed. In synthetic water, bromate was formed from the oxidation of bromide. In natural brackish waters, bromoform (CHBr3), bromoacetic acid (MBAA), dibromoacetic acid (DBAA), and tribromoacetic acid (TBAA) formed at up to 260, 106, 230, and 89 μg/L, respectively for doses of 2 mM (ca. 150 mg/L) PAA and [H2O2] < [PAA]. The same brackish waters, treated with PAA with [H2O2] ≫ [PAA], similar to conditions found in commercial PAA solutions, resulted in no trihalomethanes and only low haloacetic acid concentrations.

  6. Comparative Biomechanical and Microstructural Analysis of Native versus Peracetic Acid-Ethanol Treated Cancellous Bone Graft

    PubMed Central

    Rauh, Juliane; Despang, Florian; Baas, Jorgen; Liebers, Cornelia; Pruss, Axel; Günther, Klaus-Peter; Stiehler, Maik

    2014-01-01

    Bone transplantation is frequently used for the treatment of large osseous defects. The availability of autologous bone grafts as the current biological gold standard is limited and there is a risk of donor site morbidity. Allogenic bone grafts are an appealing alternative, but disinfection should be considered to reduce transmission of infection disorders. Peracetic acid-ethanol (PE) treatment has been proven reliable and effective for disinfection of human bone allografts. The purpose of this study was to evaluate the effects of PE treatment on the biomechanical properties and microstructure of cancellous bone grafts (CBG). Forty-eight human CBG cylinders were either treated by PE or frozen at −20°C and subjected to compression testing and histological and scanning electron microscopy (SEM) analysis. The levels of compressive strength, stiffness (Young's modulus), and fracture energy were significantly decreased upon PE treatment by 54%, 59%, and 36%, respectively. Furthermore, PE-treated CBG demonstrated a 42% increase in ultimate strain. SEM revealed a modified microstructure of CBG with an exposed collagen fiber network after PE treatment. We conclude that the observed reduced compressive strength and reduced stiffness may be beneficial during tissue remodeling thereby explaining the excellent clinical performance of PE-treated CBG. PMID:24678514

  7. Nondeterministic computational fluid dynamics modeling of Escherichia coli inactivation by peracetic acid in municipal wastewater contact tanks.

    PubMed

    Santoro, Domenico; Crapulli, Ferdinando; Raisee, Mehrdad; Raspa, Giuseppe; Haas, Charles N

    2015-06-16

    Wastewater disinfection processes are typically designed according to heuristics derived from batch experiments in which the interaction among wastewater quality, reactor hydraulics, and inactivation kinetics is often neglected. In this paper, a computational fluid dynamics (CFD) study was conducted in a nondeterministic (ND) modeling framework to predict the Escherichia coli inactivation by peracetic acid (PAA) in municipal contact tanks fed by secondary settled wastewater effluent. The extent and variability associated with the observed inactivation kinetics were both satisfactorily predicted by the stochastic inactivation model at a 95% confidence level. Moreover, it was found that (a) the process variability induced by reactor hydraulics is negligible when compared to the one caused by inactivation kinetics, (b) the PAA dose required for meeting regulations is dictated equally by the fixed limit of the microbial concentration as well as its probability of occurrence, and (c) neglecting the probability of occurrence during process sizing could lead to an underestimation of the PAA dose required by as much as 100%. Finally, the ND-CFD model was used to generate sizing information in the form of probabilistic disinfection curves relating E. coli inactivation and probability of occurrence with the average PAA dose and PAA residual concentration at the outlet of the contact tank.

  8. Phytochemical profiling as a solution to palliate disinfectant limitations.

    PubMed

    Malheiro, J; Gomes, I; Borges, A; Bastos, M M S M; Maillard, J-Y; Borges, F; Simões, M

    2016-10-01

    The indiscriminate use of biocides for general disinfection has contributed to the increased incidence of antimicrobial tolerant microorganisms. This study aims to assess the potential of seven phytochemicals (tyrosol, caffeic acid, ferulic acid, cinnamaldehyde, coumaric acid, cinnamic acid and eugenol) in the control of planktonic and sessile cells of Staphylococcus aureus and Escherichia coli. Cinnamaldehyde and eugenol showed antimicrobial properties, minimum inhibitory concentrations of 3-5 and 5-12 mM and minimum bactericidal concentrations of 10-12 and 10-14 mM against S. aureus and E. coli, respectively. Cinnamic acid was able to completely control adhered bacteria with effects comparable to peracetic acid and sodium hypochlorite and it was more effective than hydrogen peroxide (all at 10 mM). This phytochemical caused significant changes in bacterial membrane hydrophilicity. The observed effectiveness of phytochemicals makes them interesting alternatives and/or complementary products to commonly used biocidal products. Cinnamic acid is of particular interest for the control of sessile cells.

  9. Fungicidal effect of 15 disinfectants against 25 fungal contaminants commonly found in bread and cheese manufacturing.

    PubMed

    Bundgaard-Nielsen, K; Nielsen, P V

    1996-03-01

    Resistance of 19 mold and 6 yeast species to 15 commercial disinfectants was investigated by using a suspension method in which the fungicidal effect and germination time were determined at 20 degrees C. Disinfectants containing 0.5% dodecyldiethylentriaminacetic acid, 10 g of chloramine-T per 1, 2.0% formaldehyde, 0.1% potassium hydroxide, 3.0% hydrogen peroxide, or 0.3% peracetic acid were ineffective as fungicides. The fungicidal effect of quaternary ammonium compounds and chlorine compounds showed great variability between species and among the six isolates of Penicillium roqueforti var. roqueforti tested. The isolates of P roqueforti var. carneum, P. discolor, Aspergillus versicolor, and Eurotium repens examined were resistant to different quaternary ammonium compounds. Conidia and vegetative cells were killed by alcohols, whereas ascospores were resistant. Resistance of ascospores to 70% ethanol increased with age. Both P. roqueforti var. roqueforti and E. repens showed great variability of resistance within isolates of each species.

  10. Effect of different disinfection protocols on microbial and biofilm contamination of dental unit waterlines in community dental practices.

    PubMed

    Dallolio, Laura; Scuderi, Amalia; Rini, Maria S; Valente, Sabrina; Farruggia, Patrizia; Sabattini, Maria A Bucci; Pasquinelli, Gianandrea; Acacci, Anna; Roncarati, Greta; Leoni, Erica

    2014-02-18

    Output water from dental unit waterlines (DUWLs) may be a potential source of infection for both dental healthcare staff and patients. This study compared the efficacy of different disinfection methods with regard to the water quality and the presence of biofilm in DUWLs. Five dental units operating in a public dental health care setting were selected. The control dental unit had no disinfection system; two were disinfected intermittently with peracetic acid/hydrogen peroxide 0.26% and two underwent continuous disinfection with hydrogen peroxide/silver ions (0.02%) and stabilized chlorine dioxide (0.22%), respectively. After three months of applying the disinfection protocols, continuous disinfection systems were more effective than intermittent systems in reducing the microbial contamination of the water, allowing compliance with the CDC guidelines and the European Council regulatory thresholds for drinking water. P. aeruginosa, Legionella spp, sulphite-reducing Clostridium spores, S. aureus and β-haemolytic streptococci were also absent from units treated with continuous disinfection. The biofilm covering the DUWLs was more extensive, thicker and more friable in the intermittent disinfection dental units than in those with continuous disinfection. Overall, the findings showed that the products used for continuous disinfection of dental unit waterlines showed statistically better results than the intermittent treatment products under the study conditions.

  11. Peracetic Acid as a Green Disinfectant for Combined Sewer ...

    EPA Pesticide Factsheets

    This cooperative research and development agreement between U.S. EPA, Solvay, MSDGC, and CB&I is evaluating the potential of PAA for disinfection of Muddy Creek CSO wastewater and comparing that with sodium hypochlorite disinfection. This presentation will document the effectiveness of sodium hypochlorite and PAA for the inactivation of E. coli in CSO wastewater using laboratory bench-scale jar tests and Muddy Creek field site studies based on the following items:•Storage, shelf life, and application of the disinfectants.•Effectiveness of the disinfectants in the inactivation of E. coli.•Formation of harmful byproducts by the disinfectants.•Operation and maintenance costs, including the cost of the disinfectant, its storage, application, and neutralizing agent for the disinfectant to maintain the Ohio EPA guideline for residual disinfectant at the discharge point. Like many cities in the USA, Cincinnati, Ohio is attempting to find the best way to meet state and federal requirements concerning combined sewer overflow (CSO) wastewater. The Muddy Creek CSO treatment facility was constructed to provide treatment for CSO Numbers 198 and 216 from the Westwood Trunk sewer. The Metropolitan Sewer District of Greater Cincinnati (MSDGC) is currently using sodium hypochlorite for disinfection in this treatment facility. Because of degradation of hypochlorite during storage and the formation of chlorinated disinfection byproducts (DBPs), MSDGC is evaluating alternat

  12. Effect of Different Disinfection Protocols on Microbial and Biofilm Contamination of Dental Unit Waterlines in Community Dental Practices

    PubMed Central

    Dallolio, Laura; Scuderi, Amalia; Rini, Maria S.; Valente, Sabrina; Farruggia, Patrizia; Bucci Sabattini, Maria A.; Pasquinelli, Gianandrea; Acacci, Anna; Roncarati, Greta; Leoni, Erica

    2014-01-01

    Output water from dental unit waterlines (DUWLs) may be a potential source of infection for both dental healthcare staff and patients. This study compared the efficacy of different disinfection methods with regard to the water quality and the presence of biofilm in DUWLs. Five dental units operating in a public dental health care setting were selected. The control dental unit had no disinfection system; two were disinfected intermittently with peracetic acid/hydrogen peroxide 0.26% and two underwent continuous disinfection with hydrogen peroxide/silver ions (0.02%) and stabilized chlorine dioxide (0.22%), respectively. After three months of applying the disinfection protocols, continuous disinfection systems were more effective than intermittent systems in reducing the microbial contamination of the water, allowing compliance with the CDC guidelines and the European Council regulatory thresholds for drinking water. P. aeruginosa, Legionella spp, sulphite-reducing Clostridium spores, S. aureus and β-haemolytic streptococci were also absent from units treated with continuous disinfection. The biofilm covering the DUWLs was more extensive, thicker and more friable in the intermittent disinfection dental units than in those with continuous disinfection. Overall, the findings showed that the products used for continuous disinfection of dental unit waterlines showed statistically better results than the intermittent treatment products under the study conditions. PMID:24552789

  13. Disinfection of human skin allografts in tissue banking: a systematic review report.

    PubMed

    Johnston, C; Callum, J; Mohr, J; Duong, A; Garibaldi, A; Simunovic, N; Ayeni, O R

    2016-12-01

    The use of skin allografts to temporarily replace lost or damaged skin is practiced worldwide. Naturally occurring contamination can be present on skin or can be introduced at recovery or during processing. This contamination can pose a threat to allograft recipients. Bacterial culture and disinfection of allografts are mandated, but the specific practices and methodologies are not dictated by standards. A systematic review of literature from three databases found 12 research articles that evaluated bioburden reduction processes of skin grafts. The use of broad spectrum antibiotics and antifungal agents was the most frequently identified disinfection method reported demonstrating reductions in contamination rates. It was determined that the greatest reduction in the skin allograft contamination rates utilized 0.1 % peracetic acid or 25 kGy of gamma irradiation at lower temperatures.

  14. Prevalence of Visible and Occult Blood on Airway Management Equipment Used Outside the Operating Room

    DTIC Science & Technology

    1999-10-01

    under pressure, dry heat, ethylene oxide gas, and liquid chemicals such as peracetic acid. Disinfection. A process that eliminates many or all...Laryngoscope Blade. Portion of the laryngoscope that is inserted into the patient s mouth . Blades vary in size and can be curved (Macintosh) or straight...established SOP s by units such as the Medical/Surgical ICU staff most likely explains the reduced overall prevalence of occult blood. Recommendations

  15. Comparative Inactivation of Murine Norovirus and MS2 Bacteriophage by Peracetic Acid and Monochloramine in Municipal Secondary Wastewater Effluent.

    PubMed

    Dunkin, Nathan; Weng, ShihChi; Schwab, Kellogg J; McQuarrie, James; Bell, Kati; Jacangelo, Joseph G

    2017-03-07

    Chlorination has long been used for disinfection of municipal wastewater (MWW) effluent while the use peracetic acid (PAA) has been proposed more recently in the United States. Previous work has demonstrated the bactericidal effectiveness of PAA and monochloramine in wastewater, but limited information is available for viruses, especially ones of mammalian origin (e.g., norovirus). Therefore, a comparative assessment was performed of the virucidal efficacy of PAA and monochloramine against murine norovirus (MNV) and MS2 bacteriophage in secondary effluent MWW and phosphate buffer (PB). A suite of inactivation kinetic models was fit to the viral inactivation data. Predicted concentration-time (CT) values for 1-log 10 MS2 reduction by PAA and monochloramine in MWW were 1254 and 1228 mg-min/L, respectively. The 1-, 2-, and 3-log 10 model predicted CT values for MNV viral reduction in MWW were 32, 47, and 69 mg-min/L for PAA and 6, 13, and 28 mg-min/L for monochloramine, respectively. Wastewater treatment plant disinfection practices informed by MS2 inactivation data will likely be protective for public health but may overestimate CT values for reduction of MNV. Additionally, equivalent CT values in PB resulted in greater viral reduction which indicate that viral inactivation data in laboratory grade water may not be generalizable to MWW applications.

  16. Defence strategies and antibiotic resistance gene abundance in enterococci under stress by exposure to low doses of peracetic acid.

    PubMed

    Turolla, Andrea; Sabatino, Raffaella; Fontaneto, Diego; Eckert, Ester M; Colinas, Noemi; Corno, Gianluca; Citterio, Barbara; Biavasco, Francesca; Antonelli, Manuela; Mauro, Alessandro; Mangiaterra, Gianmarco; Di Cesare, Andrea

    2017-10-01

    Peracetic acid (PAA) is an organic compound used efficiently as disinfectant in wastewater treatments. Yet, at low doses it may cause selection; thus, the effect of low doses of PAA on Enterococcus faecium as a proxy of human-related microbial waste was evaluated. Bacteria were treated with increasing doses of PAA (from 0 to 25 mg L -1 min) and incubated in regrowth experiments under non-growing, limiting conditions and under growing, favorable conditions. The changes in bacterial abundance, in bacterial phenotype (number and composition of small cell clusters), and in the abundance of an antibiotic resistance gene (ARG) was evaluated. The experiment demonstrated that the selected doses of PAA efficiently removed enterococci, and induced a long-lasting effect after PAA inactivation. The relative abundance of small clusters increased during the experiment when compared with that of the inoculum. Moreover, under growing favorable conditions the relative abundance of small clusters decreased and the number of cells per cluster increased with increasing PAA doses. A strong stability of the measured ARG was found, not showing any effect during the whole experiment. The results demonstrated the feasibility of low doses of PAA to inactivate bacteria. However, the stress induced by PAA disinfection promoted a bacterial adaptation, even if potentially without affecting the abundance of the ARG. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. A simple method for decomposition of peracetic acid in a microalgal cultivation system.

    PubMed

    Sung, Min-Gyu; Lee, Hansol; Nam, Kibok; Rexroth, Sascha; Rögner, Matthias; Kwon, Jong-Hee; Yang, Ji-Won

    2015-03-01

    A cost-efficient process devoid of several washing steps was developed, which is related to direct cultivation following the decomposition of the sterilizer. Peracetic acid (PAA) is known to be an efficient antimicrobial agent due to its high oxidizing potential. Sterilization by 2 mM PAA demands at least 1 h incubation time for an effective disinfection. Direct degradation of PAA was demonstrated by utilizing components in conventional algal medium. Consequently, ferric ion and pH buffer (HEPES) showed a synergetic effect for the decomposition of PAA within 6 h. On the contrary, NaNO3, one of the main components in algal media, inhibits the decomposition of PAA. The improved growth of Chlorella vulgaris and Synechocystis PCC6803 was observed in the prepared BG11 by decomposition of PAA. This process involving sterilization and decomposition of PAA should help cost-efficient management of photobioreactors in a large scale for the production of value-added products and biofuels from microalgal biomass.

  18. Acute toxicity of peracetic acid (PAA) formulations to Ichthyophthirius multifiliis theronts.

    PubMed

    Straus, David L; Meinelt, Thomas

    2009-04-01

    Peracetic acid (PAA) is an antimicrobial disinfectant used in agriculture, food processing, and medical facilities. It has recently been suggested as a means to control infestations of Ichthyophthirius multifiliis. The purpose of this study was to determine the acute toxicity of two products containing 4.5% and 40% PAA to I. multifiliis theronts from two geographically separate isolates. Theronts were exposed to concentrations of PAA in 96-well plates containing groundwater at 23 degrees C. Acute toxicity was observed over a 4-h period. No significant difference in the median lethal concentration (LC(50)) estimates was evident between the two isolates at 4 h with the 4.5% PAA product (0.146 versus 0.108 mg/l PAA), while there was a statistical difference between the 4 h LC(50) with the 40% PAA product (0.274 versus 0.158 mg/l PAA). These results suggest that PAA is toxic to I. multifiliis theronts at low concentrations and that one of the isolates was more resistant to this compound.

  19. Chemical resistance of the gram-negative bacteria to different sanitizers in a water purification system

    PubMed Central

    Mazzola, Priscila G; Martins, Alzira MS; Penna, Thereza CV

    2006-01-01

    Background Purified water for pharmaceutical purposes must be free of microbial contamination and pyrogens. Even with the additional sanitary and disinfecting treatments applied to the system (sequential operational stages), Pseudomonas aeruginosa, Pseudomonas fluorescens, Pseudomonas alcaligenes, Pseudomonas picketti, Flavobacterium aureum, Acinetobacter lowffi and Pseudomonas diminuta were isolated and identified from a thirteen-stage purification system. To evaluate the efficacy of the chemical agents used in the disinfecting process along with those used to adjust chemical characteristics of the system, over the identified bacteria, the kinetic parameter of killing time (D-value) necessary to inactivate 90% of the initial bioburden (decimal reduction time) was experimentally determined. Methods Pseudomonas aeruginosa, Pseudomonas fluorescens, Pseudomonas alcaligenes, Pseudomonas picketti, Flavobacterium aureum, Acinetobacter lowffi and Pseudomonas diminuta were called in house (wild) bacteria. Pseudomonas diminuta ATCC 11568, Pseudomonas alcaligenes INCQS , Pseudomonas aeruginosa ATCC 15442, Pseudomonas fluorescens ATCC 3178, Pseudomonas picketti ATCC 5031, Bacillus subtilis ATCC 937 and Escherichia coli ATCC 25922 were used as 'standard' bacteria to evaluate resistance at 25°C against either 0.5% citric acid, 0.5% hydrochloric acid, 70% ethanol, 0.5% sodium bisulfite, 0.4% sodium hydroxide, 0.5% sodium hypochlorite, or a mixture of 2.2% hydrogen peroxide (H2O2) and 0.45% peracetic acid. Results The efficacy of the sanitizers varied with concentration and contact time to reduce decimal logarithmic (log10) population (n cycles). To kill 90% of the initial population (or one log10 cycle), the necessary time (D-value) was for P. aeruginosa into: (i) 0.5% citric acid, D = 3.8 min; (ii) 0.5% hydrochloric acid, D = 6.9 min; (iii) 70% ethanol, D = 9.7 min; (iv) 0.5% sodium bisulfite, D = 5.3 min; (v) 0.4% sodium hydroxide, D = 14.2 min; (vi) 0.5% sodium hypochlorite, D = 7.9 min; (vii) mixture of hydrogen peroxide (2.2%) plus peracetic acid (0.45%), D = 5.5 min. Conclusion The contact time of 180 min of the system with the mixture of H2O2+ peracetic acid, a total theoretical reduction of 6 log10 cycles was attained in the water purified storage tank and distribution loop. The contact time between the water purification system (WPS) and the sanitary agents should be reviewed to reach sufficient bioburden reduction (over 6 log10). PMID:16914053

  20. Effect of Disinfectants on Preventing the Cross-Contamination of Pathogens in Fresh Produce Washing Water

    PubMed Central

    Banach, Jennifer L.; Sampers, Imca; Van Haute, Sam; van der Fels-Klerx, H.J. (Ine)

    2015-01-01

    The potential cross-contamination of pathogens between clean and contaminated produce in the washing tank is highly dependent on the water quality. Process wash water disinfectants are applied to maintain the water quality during processing. The review examines the efficacy of process wash water disinfectants during produce processing with the aim to prevent cross-contamination of pathogens. Process wash water disinfection requires short contact times so microorganisms are rapidly inactivated. Free chlorine, chlorine dioxide, ozone, and peracetic acid were considered suitable disinfectants. A disinfectant’s reactivity with the organic matter will determine the disinfectant residual, which is of paramount importance for microbial inactivation and should be monitored in situ. Furthermore, the chemical and worker safety, and the legislative framework will determine the suitability of a disinfection technique. Current research often focuses on produce decontamination and to a lesser extent on preventing cross-contamination. Further research on a sanitizer’s efficacy in the washing water is recommended at the laboratory scale, in particular with experimental designs reflecting industrial conditions. Validation on the industrial scale is warranted to better understand the overall effects of a sanitizer. PMID:26213953

  1. Reduction of Human Norovirus GI, GII, and Surrogates by Peracetic Acid and Monochloramine in Municipal Secondary Wastewater Effluent.

    PubMed

    Dunkin, Nathan; Weng, ShihChi; Coulter, Caroline G; Jacangelo, Joseph G; Schwab, Kellogg J

    2017-10-17

    The objective of this study was to characterize human norovirus (hNoV) GI and GII reductions during disinfection by peracetic acid (PAA) and monochloramine in secondary wastewater (WW) and phosphate buffer (PB) as assessed by reverse transcription-qPCR (RT-qPCR). Infectivity and RT-qPCR reductions are also presented for surrogate viruses murine norovirus (MNV) and bacteriophage MS2 under identical experimental conditions to aid in interpretation of hNoV molecular data. In WW, RT-qPCR reductions were less than 0.5 log 10 for all viruses at concentration-time (CT) values up to 450 mg-min/L except for hNoV GI, where 1 log 10 reduction was observed at CT values of less than 50 mg-min/L for monochloramine and 200 mg-min/L for PAA. In PB, hNoV GI and MNV exhibited comparable resistance to PAA and monochloramine with CT values for 2 log 10 RT-qPCR reduction between 300 and 360 mg-min/L. Less than 1 log 10 reduction was observed for MS2 and hNoV GII in PB at CT values for both disinfectants up to 450 mg-min/L. Our results indicate that hNoVs exhibit genogroup dependent resistance and that disinfection practices targeting hNoV GII will result in equivalent or greater reductions for hNoV GI. These data provide valuable comparisons between hNoV and surrogate molecular signals that can begin the process of informing regulators and engineers on WW treatment plant design and operational practices necessary to inactivate hNoVs.

  2. Disinfection Pilot Trial for Little Miami WWTP | Science ...

    EPA Pesticide Factsheets

    There is a serious interest growing nationally towards the use of PAA at various stages of public waste water treatment facilities; one of such use is secondary waste water treatment. MSDGC is currently interested in improving efficiency and economic aspects of waste water treatment. MSDGC requested for ORD’s support to evaluate alternative cost-effective disinfectants. This report herein is based on the data generated from the field pilot test conducted at the Little Miami Wastewater Treatment Plant. Chlorine assisted disinfection of wastewaters created the concern regarding the formation of high levels of toxic halogenated disinfection byproducts (DBPs) detrimental to aquatic life and public health. Peracetic acid is emerging as a green alternative to chlorine and claimed to have economic and social benefits. In addition, it is a relatively simple retrofit to the existing chlorine treated wastewater treatment facilities. PAA is appealed to possess a much lower aquatic toxicity profile than chlorine and decays rapidly in the environment, even if overdosed. As a result, PAA generally does not need a quenching step, such as dechlorination, reducing process complexity, sodium pollution and cost. PAA treatment does not result in the formation of chlorinated disinfection by-products such as trihalomethanes (THMs), haloacetic acids and other byproducts such as cyanide and n-Nitrosodimethylamine (NDMA).

  3. Decontamination of Drinking Water Infrastructure ...

    EPA Pesticide Factsheets

    Technical Brief This study examines the effectiveness of decontaminating corroded iron and cement-mortar coupons that have been contaminated with spores of Bacillus atrophaeus subsp. globigii (B. globigii), which is often used as a surrogate for pathogenic B. anthracis (anthrax) in disinfection studies. Bacillus spores are persistent on common drinking water material surfaces like corroded iron, requiring physical or chemical methods to decontaminate the infrastructure. In the United States, free chlorine and monochloramine are the primary chemical disinfectants used by the drinking water industry to inactivate microorganisms. Flushing is also a common, easily implemented practice in drinking water distribution systems, although large volumes of contaminated water needing treatment could be generated. Identifying readily available alternative disinfectant formulations for infrastructure decontamination could give water utilities options for responding to specific types of contamination events. In addition to presenting data on flushing alone, which demonstrated the persistence of spores on water infrastructure in the absence of high levels of disinfectants, data on acidified nitrite, chlorine dioxide, free chlorine, monochloramine, ozone, peracetic acid, and followed by flushing are provided.

  4. Disinfection of human musculoskeletal allografts in tissue banking: a systematic review.

    PubMed

    Mohr, J; Germain, M; Winters, M; Fraser, S; Duong, A; Garibaldi, A; Simunovic, N; Alsop, D; Dao, D; Bessemer, R; Ayeni, O R

    2016-12-01

    Musculoskeletal allografts are typically disinfected using antibiotics, irradiation or chemical methods but protocols vary significantly between tissue banks. It is likely that different disinfection protocols will not have the same level of microorganism kill; they may also have varying effects on the structural integrity of the tissue, which could lead to significant differences in terms of clinical outcome in recipients. Ideally, a disinfection protocol should achieve the greatest bioburden reduction with the lowest possible impact on tissue integrity. A systematic review of three databases found 68 laboratory and clinical studies that analyzed the microbial bioburden or contamination rates of musculoskeletal allografts. The use of peracetic acid-ethanol or ionizing radiation was found to be most effective for disinfection of tissues. The use of irradiation is the most frequently published method for the terminal sterilization of musculoskeletal allografts; it is widely used and its efficacy is well documented in the literature. However, effective disinfection results were still observed using the BioCleanse™ Tissue Sterilization process, pulsatile lavage with antibiotics, ethylene oxide, and chlorhexidine. The variety of effective methods to reduce contamination rate or bioburden, in conjunction with limited high quality evidence provides little support for the recommendation of a single bioburden reduction method.

  5. [Determination of peracetic acid and hydrogen peroxide in a preparation].

    PubMed

    Bodiroga, Milanka; Ognjanović, Jasminka

    2002-01-01

    Iodometric and permanganometric titrations were used for determination of peracetic acid and hydrogen peroxide (H2O2) in the mixture. Two procedures were described and compared. Titrations could be done in only one vessel, in the same reaction mixture, when iodometric titration of peracetic acid was continued after the permanganometric titration of H2O2, (procedure A). Peracetic acid and H2O2, as oxidizing agents, reacted with potassium iodide in an acid medium, evolving iodine. This reaction was used for the quantitative iodometric determination of total peroxide in procedure B. H2O2 reacted with potassium permanganate in acid medium, but peracetic acid did not react under the same conditions. That made possible the selective permanganometric determination of H2O2 in the presence of peracetic acid. The procedure B was performed in two titration vessels (KV = 3.4% for peracetic acid, 0.6% for H2O2). The procedure A for iodometric determination of peracetic acid in one titration vessel after permanganometric titration of H2O2 was recommended (KV = 2.5% for peracetic acid, 0.45% for H2O2).

  6. Innovative Plasma Disinfection Technique with the Reduced-pH Method and the Plasma-Treated Water (PTW) -Safety and Powerful Disinfection with Cryopreserved PTW-

    NASA Astrophysics Data System (ADS)

    Kitano, Katsuhisa; Ikawa, Satoshi; Nakashima, Yoichi; Tani, Atsushi; Yokoyama, Takashi; Ohshima, Tomoko

    2015-09-01

    Among the applications of the plasma disinfection to human body, plasma sterilization in liquid is crucial. We found that the plasma-treated water (PTW) has strong bactericidal activity under low pH condition and the half-lives of its activity depend on temperature. Lower temperature brings longer half-life and the bactericidal activity of PTW can be kept by cryopreservation. These physicochemical properties were in accordance with Arrhenius equation both in liquid and solid states. From the experimental results of ESR (Electron Spin Resonance) measurement of O2-in liquid against PTW with spin trapping method, half-lives of PTW were also in accordance with Arrhenius equation. It suggests that high concentration PTW as integrated value can be achieved by cooling of plasma apparatus. Pure PTW has disinfection power of 22 log reduction (B. subtilis). This corresponds to 65% H2O2, 14% hypochlorous acid and 0.33% peracetic acid, which are deadly poison for human. On the other hand, PTW is deactivated soon at body temperature. This indicates that toxicity to human body seems to be low. PTW, which is a sort of indirect plasma exposure, with pH and temperature controls could be applied for safety and powerful disinfection. MEXT (15H03583, 23340176, 25108505). NCCE (23-A-15).

  7. 78 FR 8040 - National Organic Program; Proposed Amendments to the National List of Allowed and Prohibited...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-05

    ... oxidizing agent formed by a reaction of hydrogen peroxide with acetic acid in water. The reaction used to... peracetic acid. Peracetic acid is produced from the in situ reaction of acetic acid, an inert ingredient... annotation for both listings of peracetic acid.\\3\\ A second motion to list peracetic acid without any...

  8. In situ disinfection of sewage contaminated shallow groundwater: a feasibility study.

    PubMed

    Bailey, Morgan M; Cooper, William J; Grant, Stanley B

    2011-11-01

    Sewage-contaminated shallow groundwater is a potential cause of beach closures and water quality impairment in marine coastal communities. In this study we set out to evaluate the feasibility of several strategies for disinfecting sewage-contaminated shallow groundwater before it reaches the coastline. The disinfection rates of Escherichia coli (EC) and enterococci bacteria (ENT) were measured in mixtures of raw sewage and brackish shallow groundwater collected from a coastal community in southern California. Different disinfection strategies were explored, ranging from benign (aeration alone, and aeration with addition of brine) to aggressive (chemical disinfectants peracetic acid (PAA) or peroxymonosulfate (Oxone)). Aeration alone and aeration with brine did not significantly reduce the concentration of EC and ENT after 6 h of exposure, while 4-5 mg L(-1) of PAA or Oxone achieved >3 log reduction after 15 min of exposure. Oxone disinfection was more rapid at higher salinities, most likely due to the formation of secondary oxidants (e.g., bromine and chlorine) that make this disinfectant inappropriate for marine applications. Using a Lagrangian modeling framework, we identify several factors that could influence the performance of in-situ disinfection with PAA, including the potential for bacterial regrowth, and the non-linear dependence of disinfection rate upon the residence time of water in the shallow groundwater. The data and analysis presented in this paper provide a framework for evaluating the feasibility of in-situ disinfection of shallow groundwater, and elucidate several topics that warrant further investigation. Copyright © 2011 Elsevier Ltd. All rights reserved.

  9. Peracetic acid disinfection kinetics for combined sewer overflows: indicator organisms, antibiotic resistance genes, and microbial community.

    PubMed

    Eramo, Alessia; Medina, William Morales; Fahrenfeld, Nicole L

    2017-01-01

    Combined sewer overflows (CSOs) degrade water quality and end-of-pipe treatment is one potential solution for retrofitting this outdated infrastructure. The goal of this research was to evaluate peracetic acid (PAA) as a disinfectant for CSOs using viability based molecular methods for antibiotic resistance genes (ARGs), indicator organism marker gene BacHum, and 16S rRNA genes. Simulated CSO effluent was prepared using 23-40% wastewater, representing the higher end of the range of wastewater concentrations reported in CSO effluent. PAA residual following disinfection was greatest for samples with the lowest initial COD. Treatment of simulated CSO effluent (23% wastewater) with 100 mg∙min/L PAA (5 mg/L PAA, 20 min) was needed to reduce viable cell sul 1, tet (G), and BacHum (1.0±0.63-3.2±0.25-log) while 25 to 50 mg•min/L PAA (5 mg/L PAA, 5-10 min) was needed to reduce viable cell loads (0.62±0.56-1.6±0.08-log) in 40% wastewater from a different municipal treatment plant. Increasing contact time after the initial decrease in viable cell gene copies did not significantly improve treatment. A much greater applied Ct of 1200 mg∙min/L PAA (20 mg/L PAA, 60 min) was required for significant log reduction of 16S rRNA genes (3.29±0.13-log). No significant losses of mex B were observed during the study. Data were fitted to a Chick-Watson model and resulting inactivation constants for sul 1 and tet (G) > BacHum > 16S rRNA. Amplicon sequencing of the 16S rRNA gene indicated the initial viable and total microbial communities were distinct and that treatment with PAA resulted in marked increases of the relative abundance of select phyla, particularly Clostridia which increased by 1-1.5 orders of magnitude. Results confirm that membrane disruption is a mechanism for PAA disinfection and further treatment is needed to reduce total ARGs in CSO effluent.

  10. Modern technologies for improving cleaning and disinfection of environmental surfaces in hospitals.

    PubMed

    Boyce, John M

    2016-01-01

    Experts agree that careful cleaning and disinfection of environmental surfaces are essential elements of effective infection prevention programs. However, traditional manual cleaning and disinfection practices in hospitals are often suboptimal. This is often due in part to a variety of personnel issues that many Environmental Services departments encounter. Failure to follow manufacturer's recommendations for disinfectant use and lack of antimicrobial activity of some disinfectants against healthcare-associated pathogens may also affect the efficacy of disinfection practices. Improved hydrogen peroxide-based liquid surface disinfectants and a combination product containing peracetic acid and hydrogen peroxide are effective alternatives to disinfectants currently in widespread use, and electrolyzed water (hypochlorous acid) and cold atmospheric pressure plasma show potential for use in hospitals. Creating "self-disinfecting" surfaces by coating medical equipment with metals such as copper or silver, or applying liquid compounds that have persistent antimicrobial activity surfaces are additional strategies that require further investigation. Newer "no-touch" (automated) decontamination technologies include aerosol and vaporized hydrogen peroxide, mobile devices that emit continuous ultraviolet (UV-C) light, a pulsed-xenon UV light system, and use of high-intensity narrow-spectrum (405 nm) light. These "no-touch" technologies have been shown to reduce bacterial contamination of surfaces. A micro-condensation hydrogen peroxide system has been associated in multiple studies with reductions in healthcare-associated colonization or infection, while there is more limited evidence of infection reduction by the pulsed-xenon system. A recently completed prospective, randomized controlled trial of continuous UV-C light should help determine the extent to which this technology can reduce healthcare-associated colonization and infections. In conclusion, continued efforts to improve traditional manual disinfection of surfaces are needed. In addition, Environmental Services departments should consider the use of newer disinfectants and no-touch decontamination technologies to improve disinfection of surfaces in healthcare.

  11. Use of a Mixture of Surrogates for Infectious Bioagents in a Standard Approach to Assessing Disinfection of Environmental Surfaces ▿

    PubMed Central

    Sabbah, Safaa; Springthorpe, Susan; Sattar, Syed A.

    2010-01-01

    We used a mixture of surrogates (Acinetobacter baumannii, Mycobacterium terrae, hepatitis A virus, and spores of Geobacillus stearothermophilus) for bioagents in a standardized approach to test environmental surface disinfectants. Each carrier containing 10 μl of mixture received 50 μl of a test chemical or saline at 22 ± 2°C. Disinfectant efficacy criteria were ≥6 log10 reduction for the bacteria and the spores and ≥3 log10 reduction for the virus. Peracetic acid (1,000 ppm) was effective in 5 min against the two bacteria and the spores but not against the virus. Chlorine dioxide (CD; 500 and 1,000 ppm) and domestic bleach (DB; 2,500, 3,500, and 5,000 ppm) were effective in 5 min, except for sporicidal activity, which needed 20 min of contact with either 1,000 ppm of CD or the two higher concentrations of DB. PMID:20639366

  12. Mycobacterium massiliense BRA100 strain recovered from postsurgical infections: resistance to high concentrations of glutaraldehyde and alternative solutions for high level disinfection.

    PubMed

    Lorena, Nádia Suely de Oliveira; Pitombo, Marcos Bettini; Côrtes, Patrícia Barbur; Maya, Maria Cristina Araújo; Silva, Marlei Gomes da; Carvalho, Ana Carolina da Silva; Coelho, Fábrice Santana; Miyazaki, Neide Hiromi Tokumaru; Marques, Elizabeth Andrade; Chebabo, Alberto; Freitas, Andréa D'Avila; Lupi, Otília; Duarte, Rafael Silva

    2010-10-01

    To evaluate the minimum inhibitory concentration (MIC) of GTA against these microorganisms and alternative disinfectants for high-level disinfection (HLD). Reference mycobacteria and clinical M. massiliense strains were included in this study. Active cultures were submitted to susceptibility qualitative tests with GTA dilutions (ranging from 1.5% to 8%), and commercial orthophthaldehyde (OPA) and peracetic acid (PA)-based solutions, during the period of exposure as recommended by National Agency of Sanitary Surveillance for HLD. All reference and M. massiliense non-BRA100 strains, recovered from sputum, were susceptible to any GTA concentration, OPA and PA solutions. M. massiliense BRA100 strains presented MIC of 8% GTA and were susceptible to OPA and PA. M. massiliense BRA100 strain is resistant to high GTA concentrations (up to 7%), which proves that this product is non-effective against specific rapidly growing mycobacteria and should be substituted by OPA or PA-based solutions for HLD.

  13. Efficacy of chemical disinfectants for the containment of the salamander chytrid fungus Batrachochytrium salamandrivorans.

    PubMed

    Van Rooij, Pascale; Pasmans, Frank; Coen, Yanaika; Martel, An

    2017-01-01

    The recently emerged chytrid fungus Batrachochytrium salamandrivorans (Bsal) causes European salamander declines. Proper hygiene protocols including disinfection procedures are crucial to prevent disease transmission. Here, the efficacy of chemical disinfectants in killing Bsal was evaluated. At all tested conditions, Biocidal®, Chloramine-T®, Dettol medical®, Disolol®, ethanol, F10®, Hibiscrub®, potassium permanganate, Safe4®, sodium hypochlorite, and Virkon S®, were effective at killing Bsal. Concentrations of 5% sodium chloride or lower, 0.01% peracetic acid and 0.001-1% copper sulphate were inactive against Bsal. None of the conditions tested for hydrogen peroxide affected Bsal viability, while it did kill Batrachochytrium dendrobatidis (Bd). For Bsal, enzymatic breakdown of hydrogen peroxide by catalases and specific morphological features (clustering of sporangia, development of new sporangia within the original sporangium), were identified as fungal factors altering susceptibility to several of the disinfectants tested. Based on the in vitro results we recommend 1% Virkon S®, 4% sodium hypochlorite and 70% ethanol for disinfecting equipment in the field, lab or captive setting, with a minimal contact time of 5 minutes for 1% Virkon S® and 1 minute for the latter disinfectants. These conditions not only efficiently target Bsal, but also Bd and Ranavirus.

  14. Resistance of pathogenic and spoilage microorganisms to disinfectants in the presence of organic matter and their residual effect on stainless steel and polypropylene.

    PubMed

    Iñiguez-Moreno, Maricarmen

    2018-04-23

    The effectiveness of disinfectants can vary according to the microorganism, type of residues and surface. Hence, the aim of this study was to determine the effectiveness of four disinfectants in the presence of organic matter and their residual effect on stainless steel grade 304 (SS) and polypropylene B (PP-B). The disinfectant effectiveness in the presence of meat extract, yolk egg and whole milk was determined according to AOAC and UNE-EN 1040:2015; the residual effect was realized according to UNE-EN 13697:2015, using approved strains. The disinfectant effectiveness was affect at different grades depending on the organic matter present; disinfectant A (400μgmL -1 , fifth generation quaternary ammonium compound, QAC) was most effective in the presence of 10% meat extract, while the disinfectant C (200μgmL -1 , peracetic acid) had better activity in the presence of 10% egg yolk and whole milk. In the evaluation of residual effect onto SS and PP-B, the QAC had the better effect, reducing 6 Log 10 CFU mL -1 of Listeria monocytogenes ATCC 19111 24h after their application. Conversely, the disinfectants had no residual effect against Pseudomonas aeruginosa ATCC 15442. The antimicrobial activity of disinfectants tested against pathogenic and spoilage microorganisms was affected according to the type of organic matter. Disinfectant A had a more residual effect than the other disinfectants evaluated. Moreover, the residual effect of a disinfectant is greater on SS than on PP-B and dependent on the microorganism tested. Copyright © 2018. Published by Elsevier Ltd.

  15. Disinfection efficiency of peracetic acid, UV and ozone after enhanced primary treatment of municipal wastewater.

    PubMed

    Gehr, Ronald; Wagner, Monika; Veerasubramanian, Priya; Payment, Pierre

    2003-11-01

    The City of Montreal Wastewater Treatment Plant uses enhanced physicochemical processes (ferric and/or alum coagulation) for suspended solids and phosphorus removal. The objective of this study was to assess the ability of peracetic acid (PAA), UV, or ozone to inactivate the indicator organisms fecal coliforms, Enterococci, MS-2 coliphage, or Clostridium perfringens in the effluent from this plant. PAA doses to reach the target fecal coliform level of 9000 CFU/100mL exceeded 6 mg/L; similar results were obtained for enterococci, and no inactivation of Clostridium perfringens was observed. However a 1-log reduction of MS-2 occurred at PAA doses of 1.5 mg/L and higher. It was expected that this effluent would have a high ozone demand, and would require relatively high UV fluences, because of relatively high effluent COD, iron and suspended solids concentrations, and low UV transmittance. This was confirmed herein. For UV, the inactivation curve for fecal coliforms showed the typical two-stage shape, with the target of 1000 CFU/100 mL (to account for photoreactivation) occurring in the asymptote zone at fluences >20 mJ/cm(2). In contrast, inactivation curves for MS-2 and Clostridium perfringens were linear. Clostridium perfringens was the most resistant organism. For ozone, inactivation was already observed before any residuals could be measured. The transferred ozone doses to reach target fecal coliform levels ( approximately 2-log reduction) were 30-50 mg/L. MS-2 was less resistant, but Clostridium perfringens was more resistant than fecal coliforms. The different behaviour of the four indicator organisms studied, depending on the disinfectant, suggests that a single indicator organism might not be appropriate. The required dose of any of the disinfectants is unlikely to be economically viable, and upstream changes to the plant will be needed.

  16. Simultaneous saccharification and cofermentation of peracetic acid-pretreated biomass.

    PubMed

    Teixeira, L C; Linden, J C; Schroeder, H A

    2000-01-01

    Previous work in our laboratories has demonstrated the effectiveness of peracetic acid for improving enzymatic digestibility of lignocellulosic materials. The use of dilute alkali solutions as a pre-pretreatment prior to peracetic acid lignin oxidation increased carbohydrate hydrolysis yields in a synergistic as opposed to additive manner. Deacetylation of xylan is easily achieved using dilute alkali solutions under mild conditions. In this article, we evaluate the effectiveness of peracetic acid combined with an alkaline pre-pretreatment through simultaneous saccharification and cofermentation (SSCF) of pretreated hybrid poplar wood and sugar cane bagasse. Respective ethanol yields of 92.8 and 91.9% of theoretical are achieved using 6% NaOH/15% peracetic acid-pretreated substrates and recombinant Zymomonas mobilis CP4/pZB5. Reduction of acetyl groups of the lignocellulosic materials is demonstrated following alkaline pre-pretreatments. Such processing may be helpful in reducing peracetic acid requirements. The influence of deacetylation is more significant in combined pretreatments using lower peracetic acid loadings.

  17. Evaluation of the effectiveness of peracetic acid in the sterilization of dental equipment.

    PubMed

    Ceretta, R; Paula, M M S; Angioletto, Ev; Méier, M M; Mitellstädt, F G; Pich, C T; Junior, S A; Angioletto, E

    2008-01-01

    To evaluate the effectiveness of peracetic acid in the microbiological sterilisation of dental materials. Peracetic acid solution was evaluated at concentrations of 800, 1500 and 2500 ppm. At these concentrations, it was determined whether peracetic acid caused corrosion to dental instruments and induced cellular mutagenicity and cytotoxicity. In addition, the minimum inhibitory concentration (MIC), the minimum bactericidal concentration (MBC), agar diffusion and diffusion by well method, were also verified. The corrosion rate, calculated from potentiodynamic assays was 10(-6) cm/year, indicating that the product does not damage equipment. The sterilisation capacity of peracetic acid at 2500 ppm was the best. The comet assay indicated genotoxic activity at 2500 ppm. This study demonstrated the effectiveness of peracetic acid for sterilizing dental equipment, providing another alternative for the prevention of infections in clinics.

  18. Infectivity reduction efficacy of UV irradiation and peracetic acid-UV combined treatment on MS2 bacteriophage and murine norovirus in secondary wastewater effluent.

    PubMed

    Weng, ShihChi; Dunkin, Nathan; Schwab, Kellogg J; McQuarrie, James; Bell, Kati; Jacangelo, Joseph G

    2018-09-01

    Peracetic acid (PAA) is a strong oxidant/bactericide that has been applied in various industries (e.g., food processing, pharmaceuticals, medical device sterilization, etc.) as a disinfectant. There is increasing interest in using PAA for wastewater disinfection because it does not form halogenated byproducts, and no post-treatment quenching is required. Previous studies have demonstrated good efficiency in controlling bacteria in wastewater, but limited information is available for viruses, especially those hosted by mammals (e.g., norovirus). Therefore, a study on the infectivity reduction of murine norovirus (MNV) was undertaken to evaluate the disinfection efficacy of PAA or UV alone and in combination with UV irradiation in undisinfected secondary effluent from a municipal wastewater reclamation facility (MWW) and phosphate buffer solution (PBS) at pH 7. Experiments employing MS2 bacteriophage were also performed in parallel for comparison purposes. MS2 infectivity reduction was found to be lower than MNV infectivity reduction for each condition studied - PAA, PAA + UV, and UV disinfection. These data suggest that MS2 may not be an appropriate surrogate to accurately predict the reduction of MNV infectivity. UV irradiation, in a dose range of 5-250 mJ/cm 2 , provided linear log inactivation (-log (N/N 0 )) with a regression slope (cm 2 mJ -1 ) of 0.031-0.034 and 0.165-0.202 for MS2 and MNV, respectively. UV irradiation provided similar inactivation for MS2 and MNV in both suspensions (PBS or MWW). Low infectivity reduction of MS2 was observed when PAA was used alone at a practical dose of 1.5 mg/L and below. A greater reduction of both MNV and MS2 was observed in PAA disinfection experiments using PBS as the microbial suspension medium, than in secondary effluent. Similar results were observed in PAA + UV experiments, in which greater synergistic effects were found in PBS than in MWW. Results of OH radical formation experiments suggest the presence of radical scavengers in MWW, which resulted in less opportunity for MNV and MS2 to encounter OHradicals. This study also demonstrated that the type of water can have a substantial impact on wastewater disinfection when employing PAA or PAA + UV treatment due to the matrix effect and the presence of radical scavengers, respectively. The results from this study could be employed to aid in the conceptual design of PAA and UV disinfection facilities, especially when norovirus is the organism of concern. Copyright © 2018. Published by Elsevier Ltd.

  19. Ground and Surface Water for Drinking: A Laboratory Study on Genotoxicity Using Plant Tests

    PubMed Central

    Feretti, Donatella; Ceretti, Elisabetta; Gustavino, Bianca; Zerbini, llaria; Zani, Claudia; Monarca, Silvano; Rizzoni, Marco

    2012-01-01

    Surface waters are increasingly utilized for drinking water because groundwater sources are often polluted. Several monitoring studies have detected the presence of mutagenicity in drinking water, especially from surface sources due to the reaction of natural organic matter with disinfectant. The study aimed to investigate the genotoxic potential of the products of reaction between humic substances, which are naturally present in surface water, and three disinfectants: chlorine dioxide, sodium hypochlorite and peracetic acid. Commercial humic acids dissolved in distilled water at different total organic carbon (TOC) concentrations were studied in order to simulate natural conditions of both ground water (TOC=2.5 mg/L) and surface water (TOC=7.5 mg/L). These solutions were treated with the biocides at a 1:1 molar ratio of C:disinfectant and tested for genotoxicity using the anaphase chromosomal aberration and micronucleus tests in Allium cepa, and the Vicia faba and Tradescantia micronucleus tests. The tests were carried out after different times and with different modes of exposure, and at 1:1 and 1:10 dilutions of disinfected and undisinfected humic acid solutions. A genotoxic effect was found for sodium hypochlorite in all plant tests, at both TOCs considered, while chlorine dioxide gave positive results only with the A.cepa tests. Some positive effects were also detected for PAA (A.cepa and Tradescantia). No relevant differences were found in samples with different TOC values. The significant increase in all genotoxicity end-points induced by all tested disinfectants indicates that a genotoxic potential is exerted even in the presence of organic substances at similar concentrations to those frequently present in drinking water. PMID:25170443

  20. Disinfectant Susceptibility Profiling of Glutaraldehyde-Resistant Nontuberculous Mycobacteria.

    PubMed

    Burgess, Winona; Margolis, Alyssa; Gibbs, Sara; Duarte, Rafael Silva; Jackson, Mary

    2017-07-01

    OBJECTIVE Activated alkaline glutaraldehyde (GTA) remains one of the most widely used high-level disinfectants worldwide. However, several reports have highlighted the potential for nontuberculous mycobacteria to develop high-level resistance to this product. Because aldehyde resistance may lead to cross-resistance to other biocides, we investigated the susceptibility profile of GTA-resistant Mycobacterium chelonae and M. abscessus isolates to various disinfectant chemistries. METHODS High-level disinfectants commonly used in the reprocessing of endoscopes and other heat-sensitive, semicritical medical equipment, including different formulations of aldehyde-based products and oxidizing agents, were tested against 10 slow- and fast-growing, GTA-susceptible and GTA-resistant, Mycobacterium isolates in suspension tests and carrier tests at different temperatures. RESULTS While peracetic acid- and hydrogen peroxide-based disinfectants (S40, Resert XL, Reliance DG) efficiently killed all of the Mycobacterium isolates, GTA- and ortho-phthalaldehyde-based products (ie, Cidex, Aldahol, Cidex OPA) showed variable efficacy against GTA-resistant strains despite the ability of some formulations (Aldahol) to overcome the resistance of some of these isolates, especially when the temperature was increased from 20°C to 25°C. CONCLUSIONS Application permitting, oxidizing chemistries may provide a safe alternative to aldehyde-based products, particularly in GTA-resistant mycobacterial outbreaks. Infect Control Hosp Epidemiol 2017;38:784-791.

  1. Inactivation kinetics of various chemical disinfectants on Aeromonas hydrophila planktonic cells and biofilms.

    PubMed

    Jahid, Iqbal Kabir; Ha, Sang-Do

    2014-05-01

    The present article focuses on the inactivation kinetics of various disinfectants including ethanol, sodium hypochlorite, hydrogen peroxide, peracetic acid, and benzalkonium chloride against Aeromonas hydrophila biofilms and planktonic cells. Efficacy was determined by viable plate count and compared using a modified Weibull model. The removal of the biofilms matrix was determined by the crystal violet assay and was confirmed by field-emission scanning electron microscope. The results revealed that all the experimental data and calculated Weibull α (scale) and β (shape) parameters had a good fit, as the R(2) values were between 0.88 and 0.99. Biofilms are more resistant to disinfectants than planktonic cells. Ethanol (70%) was the most effective in killing cells in the biofilms and significantly reduced (p<0.05) the biofilms matrix. The Weibull parameter b-value correlated (R(2)=0.6835) with the biofilms matrix removal. The present findings deduce that the Weibull model is suitable to determine biofilms matrix reduction as well as the effectiveness of chemical disinfectants on biofilms. The study showed that the Weibull model could successfully be used on food and food contact surfaces to determine the exact contact time for killing biofilms-forming foodborne pathogens.

  2. Comparison of organic peracids in wastewater treatment: Disinfection, oxidation and corrosion.

    PubMed

    Luukkonen, Tero; Heyninck, Tom; Rämö, Jaakko; Lassi, Ulla

    2015-11-15

    The use of organic peracids in wastewater treatment is attracting increasing interest. The common beneficial features of peracids are effective anti-microbial properties, lack of harmful disinfection by-products and high oxidation power. In this study performic (PFA), peracetic (PAA) and perpropionic acids (PPA) were synthesized and compared in laboratory batch experiments for the inactivation of Escherichia coli and enterococci in tertiary wastewater, oxidation of bisphenol-A and for corrosive properties. Disinfection tests revealed PFA to be a more potent disinfectant than PAA or PPA. 1.5 mg L(-1) dose and 2 min of contact time already resulted in 3.0 log E. coli and 1.2 log enterococci reduction. Operational costs of disinfection were estimated to be 0.0114, 0.0261 and 0.0207 €/m(3) for PFA, PAA and PPA, respectively. Disinfection followed the first order kinetics (Hom model or S-model) with all studied peracids. However, in the bisphenol-A oxidation experiments involving Fenton-like conditions (pH = 3.5, Fe(2+) or Cu(2+) = 0.4 mM) peracids brought no additional improvement to traditionally used and lower cost hydrogen peroxide. Corrosion measurements showed peracids to cause only a negligible corrosion rate (<6 μm year(-1)) on stainless steel 316L while corrosion rates on the carbon steel sample were significantly higher (<500 μm year(-1)). Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Resistance of enterococci to heat and chemical agents.

    PubMed

    Renner, P; Peters, J

    1999-06-01

    Within the framework of the standardisation efforts on disinfectant testing on the European level the test germ Enterococcus hirae ATCC 10541 has been included for some time in the test requirements whereas the test strain Enterococcus faecium, which has frequently been used up to now, has been largely ignored. We compared the thermal and the chemical resistance of both test germ species. In the quantitative suspension test with active ingredients from the group of aldehydes, phenols, quaternaries and oxidizing agents with the exception of peracetic acid, no significant differences were determined between the two strains. In the case of the studies on thermal resistance at 65 degrees C and 68 degrees C, Enterococcus faecium ATCC 6057, by contrast, proved to be far more resistant than Enterococcus hirae ATCC 10541. According to these results, priority should be given to Enterococcus faecium over Enterococcus hirae as the test germ for chemical and also chemothermal disinfection.

  4. Suitability of peracetic acid for sterilization of media for mycoplasma cultures.

    PubMed Central

    Wutzler, P; Sprössig, M; Peterseim, H

    1975-01-01

    The utility of peracetic acid for sterilization of serum and yeast extract additions to mycoplasma medium was studied by culturing six Mycoplasma species. Culture media containing additions that had been sterilized with peracetic acid proved to be as good as filtered components. The use of 0.05 to 0.1% peracetic acid is recommended to sterilize the serum and yeast extract additions since savings in time and equipment can be accomplished. PMID:1100656

  5. Model tests for the efficacy of disinfectants on surfaces. IV. Communication: dependence of test results on the amount of contamination and the kind of active substance.

    PubMed

    Peters, J; Spicher, G

    1998-12-01

    In the assessment of efficacy of surface disinfectants, many influencing factors have to be taken into account. One essential item is whether the surface to be disinfected is clean or soiled. Among the feasible soilings, the blood is of particular consequences because it ads impediments to many disinfecting agents. This paper shows to what extent the impairment of the efficacy of typical active agents depends on the blood burden of the surfaces. Therefore, test surfaces (varnished plywood) were contaminated with 0.01 to 0.08 ml of coagulating blood per test area (3 cm2). The blood contained cells of Staphylococcus aureus as test germs. The disinfection was effected by immersing the test objects in the disinfecting solution for 5 seconds and mingling the adhering disinfecting solution (about 0.02 ml) with the coagulated blood on the test surface with a glass spatula for about 20 seconds. Subsequently, the test objects remained in a horizontal position at room conditions for 4 hours and then the numbers of surviving test germs were determined. The graphical representation of the results shows that the efficacy curves of formaldehyde and phenol lie very closely together, i.e. their effect is hardly impaired by the different blood burdens of the test areas. The efficacy curves of glutaraldehyde, peracetic acid, chloramine T, and quaternary ammonium compounds lie very far apart from each other. To achieve the same microbicidal effect (log N/N0 = -5) when the contaminating amount is raised from 10 microliters/3 cm2 to 80 microliters/3 cm2, the concentration of chloramine T has to be raised by a factor of 5.4, peracetic acid by a factor of 9, glutaraldehyde by a factor of 24, quaternary ammonium compound even by a factor of 67. Ethanol and sodium hypochlorite showed a divergent behaviour. For ethanol, the efficacy diminution produced by increasing the contamination amount by a factor of 4 can be compensated by raising the concentration from 50% to about 70%. But again and again, there were test objects on which the number of germs able to reproduce had only been lowered by a factor of about 10(-3). At the highest contamination of 80 microliters/3 cm2, even 95% ethanol proved to be completely insufficient. With sodium hypochlorite even at the lowest contamination of 10 microliters/3 cm2, a microbicidal effect of only about 10(-5) was obtained. With increasing contamination, the highest achievable microbicidal effect clearly decreased. It is remarkable that the microbicidal effect of this active agent decreased with increasing concentrations. The results show how important it is in testing the efficacy of disinfecting agents to exactly lay down the amount of contaminating substances. To find out how safely an agent works under harder circumstances, the dependence of the microbicidal effect from the amount of contaminating substances per test area has to be determined.

  6. Evaluation of the hygienogram scores and related data obtained after cleaning and disinfection of poultry houses in Flanders during the period 2007 to 2014.

    PubMed

    Maertens, H; De Reu, K; Van Weyenberg, S; Van Coillie, E; Meyer, E; Van Meirhaeghe, H; Van Immerseel, F; Vandenbroucke, V; Vanrobaeys, M; Dewulf, J

    2018-02-01

    Cleaning and disinfection (C&D) of poultry houses is an essential aspect in farm hygiene management. Adequate performance of the different steps of a C&D protocol and the use of suitable products are key to prevent and control zoonoses and animal diseases. Hygiene monitoring on total aerobic flora through sampling with agar contact plates at different locations of the poultry house results in a hygienogram score that is used to evaluate the proper execution of C&D.This study analyzed the hygienogram scores of 19,739 poultry flocks in Flanders after C&D. Data relating to the C&D protocol, i.e., year, season, husbandry system, production type, cleaning product, sampler, active components of the disinfectant, disinfection time, disinfection temperature, and disinfection responsible, were collected.The average hygienogram score decreased significantly over time, suggesting a general improvement between 2007 and 2014. Differences in scores were found among the husbandry systems, with the barn/aviary system having a significantly better hygienogram score compared to the floor house, furnished cage, and battery. Significantly better scores also were found when a cleaning product was used in the C&D protocol. Disinfection with a peracetic acid and hydrogen peroxide combination or formaldehyde gave the best scores. In addition, C&D protocols using ≥2 different disinfectants showed improved results compared to the use of one single disinfectant. Finally, disinfection applied by a specialist contractor resulted in a better score compared to disinfection by the farmer.In conclusion, analysis of the hygienogram scores and related data allowed identifying several factors, resulting in an improvement, which may reduce the total bacterial load in poultry stables and, consequently, the number of zoonotic and pathogenic micro-organisms. © 2017 Poultry Science Association Inc.

  7. Antibiotic resistant bacteria in urban sewage: Role of full-scale wastewater treatment plants on environmental spreading.

    PubMed

    Turolla, A; Cattaneo, M; Marazzi, F; Mezzanotte, V; Antonelli, M

    2018-01-01

    The presence of antibiotic resistant bacteria (ARB) in wastewater was investigated and the role of wastewater treatment plants (WWTPs) in promoting or limiting antibiotic resistance was assessed. Escherichia coli (E. coli) and total heterotrophic bacteria (THB) resistance to ampicillin, chloramphenicol and tetracycline was monitored in three WWTPs located in Milan urban area (Italy), differing among them for the operating parameters of biological process, for the disinfection processes (based on sodium hypochlorite, UV radiation, peracetic acid) and for the discharge limits to be met. Wastewater was collected from three sampling points along the treatment sequence (WWTP influent, effluent from sand filtration, WWTP effluent). Antibiotic resistance to ampicillin was observed both for E. coli and for THB. Ampicillin resistant bacteria in the WWTP influents were 20-47% of E. coli and 16-25% of THB counts. A limited resistance to chloramphenicol was observed only for E. coli, while neither for E. coli nor for THB tetracycline resistance was observed. The biological treatment and sand filtration led to a decrease in the maximum percentage of ampicillin-resistant bacteria (20-29% for E. coli, 11-21% for THB). However, the conventionally adopted parameters did not seem adequate to support an interpretation of WWTP role in ARB spread. Peracetic acid was effective in selectively acting on antibiotic resistant THB, unlike UV radiation and sodium hypochlorite. The low counts of E. coli in WWTP final effluents in case of agricultural reuse did not allow to compare the effect of the different disinfection processes on antibiotic resistance. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Comparison of the virucidal efficiency of peracetic acid, potassium monopersulfate and sodium hypochlorite on hepatitis A and enteric cytopathogenic bovine orphan virus.

    PubMed

    Martin, H; Soumet, C; Fresnel, R; Morin, T; Lamaudière, S; Le Sauvage, A L; Deleurme, K; Maris, P

    2013-10-01

    The virucidal activity of peroxy-products was evaluated and compared with sodium hypochlorite using the EN 14675 European suspension test and a surface test developed in our laboratory. The classical approach on infectivity of viruses was complemented with a prospective approach on virus genomes. Both infectivity tests were adapted and/or developed to determine the activity of disinfectants against reference bovine enterovirus type 1 [enteric cytopathogenic bovine orphan virus (ECBO)] and resistant hepatitis A virus (HAV) in conditions simulating practical use. Similar concentrations of active chlorine were virucidal against both viruses, either at 0·062% using the suspension test or at 0·50-1% using the surface test. However, for potassium monopersulfate and peracetic acid products, concentrations of approximately three times (3%) to 72 times (9%) higher were necessary against HAV than ECBO when determined with the suspension test. With the surface test, 4-8% peroxy-products were virucidal against HAV, either 16 times more peroxy-products concentrations than against ECBO. No significant impact on the targeted area of the viral genome measured by real-time RT-PCRs was obtained for ECBO and HAV suspensions treated with disinfectants, even with doses higher than the minimal virucidal concentrations. Sodium hypochlorite, but not peroxy-products, had similar activity against ECBO and HAV. No relation could be established between infectivity tests and genome destruction. This is the first comparative study that investigates with novel suspension and surface tests the reduction of infectivity and genome destruction of two resistant viruses by peroxy-compounds. The results and conclusions collected with European standards are discussed. © 2013 The Society for Applied Microbiology.

  9. Antimicrobial effect of three disinfecting agents on Resilon cones and their effect on surface topography: An in vitro study.

    PubMed

    Chandrappa, Mahesh Martur; Meharwade, Prasanna Mahadevasa; Srinivasan, Raghu; Bhandary, Shreetha; Nasreen, Farhat

    2016-01-01

    The objective of this study was to evaluate the effectiveness of 5.25% sodium hypochlorite (NaOCl), 2% chlorhexidine (CHX), and 2% peracetic acid (PAA) in disinfecting Resilon cones and to evaluate topographical changes microscopically under scanning electron microscope (SEM) after rapid chemical disinfection. Resilon cones were disinfected in an ultraviolet (UV) light chamber for 20 min and contaminated by immersing in a microbial suspension of Enterococcus faecalis for 30 min. The contaminated cones were then immersed in the 5.25% NaOCl, 2% CHX, and 2% PAA for 1 min, 5 min, and 10 min, separately. The cones were then incubated at 37°C in thioglycollate broth for 7 days and examined for turbidity. The samples showing turbidity were subcultured on blood agar and incubated at 37°C for 48 h. Gram staining was done to confirm that the cultured bacteria were E. faecalis. Surface changes of disinfected Resilon cones were evaluated under SEM. The data were analyzed statistically using Kruskal-Wallis, analysis of variance (ANOVA), and Mann-Whitney U-test. In eliminating E. faecalis, 5.25% NaOCl was most effective followed by 2% PAA and 2% CHX. Topographic examination of tested Resilon cones revealed some surface deposits after disinfection with 5.25% NaOCl and 2% CHX, whereas 2% PAA caused surface erosion. In disinfecting Resilon cones, 5.25% NaOCl is most effective followed by 2% PAA and 2% CHX.

  10. Improved pretreatment of lignocellulosic biomass using enzymatically-generated peracetic acid.

    PubMed

    Yin, DeLu Tyler; Jing, Qing; AlDajani, Waleed Wafa; Duncan, Shona; Tschirner, Ulrike; Schilling, Jonathan; Kazlauskas, Romas J

    2011-04-01

    Release of sugars from lignocellulosic biomass is inefficient because lignin, an aromatic polymer, blocks access of enzymes to the sugar polymers. Pretreatments remove lignin and disrupt its structure, thereby enhancing sugar release. In previous work, enzymatically generated peracetic acid was used to pretreat aspen wood. This pretreatment removed 45% of the lignin and the subsequent saccharification released 97% of the sugars remaining after pretreatment. In this paper, the amount of enzyme needed is reduced tenfold using first, an improved enzyme variant that makes twice as much peracetic acid and second, a two-phase reaction to generate the peracetic acid, which allows enzyme reuse. In addition, the eight pretreatment cycles are reduced to only one by increasing the volume of peracetic acid solution and increasing the temperature to 60 °C and the reaction time to 6h. For the pretreatment step, the weight ratio of peracetic acid to wood determines the amount of lignin removed. Copyright © 2011 Elsevier Ltd. All rights reserved.

  11. Effects of chelating agents on the mineral content of root canal dentin.

    PubMed

    Cobankara, Funda Kont; Erdogan, Hilal; Hamurcu, Mehmet

    2011-12-01

    The objective of this in vitro study was to assess the effect of several chelating agents on the mineral content of root dentin. Extracted human mandibular incisor roots were prepared and divided into groups according to the following irrigation protocols: 1) 17% ethylenediaminetetraacetic acid (EDTA); 2) 10% citric acid solution; 3) 18% etidronate; 4) 2.25% peracetic acid; 5) and deionized water (control). Dentin chips were obtained (Gates-Glidden nos. 3, 4, and 5). The levels of different minerals were analyzed with the use of inductively coupled plasma-atomic emission spectrometry (ICP-AES). 1) Peracetic acid significantly decreased P, K, Mg, Na, and S levels compared with the other groups (P < .05). 2) S decreased by different levels in all of the chelating solutions (P < .05), and the greatest decrease was observed in peracetic acid. 3) Ca levels significantly decreased in peracetic acid, citric acid, and EDTA (P < .05). 4) Mn levels significantly decreased in the citric acid and peracetic acid groups (P < .05). 5) Na and Zn levels significantly decreased in the peracetic acid, citric acid, and etidronate groups (P < .05). The chelation agents can create different effects on mineral contents of root dentin, so it is important to know what effects each solution will have on root dentin before their clinical use. In addition, according to the results of this in vitro study, it might be recommended that peracetic acid, in particular, should be used with caution. Copyright © 2011 Mosby, Inc. All rights reserved.

  12. Comparison of the virucidal efficacy of peracetic acid, potassium monopersulphate and sodium hypochlorite on bacteriophages P001 and MS2.

    PubMed

    Morin, T; Martin, H; Soumet, C; Fresnel, R; Lamaudière, S; Le Sauvage, A L; Deleurme, K; Maris, P

    2015-09-01

    The phagicidal activity of peroxy products against the virulent bacteriophage P001 infecting lactic acid bacteria and bacteriophage MS2 used as a surrogate of enteric viruses (EVs) was evaluated and compared to sodium hypochlorite using the EN 13610 European suspension test and a surface test developed in our laboratories. Infectivity tests were adapted and/or developed to determine the activity of disinfectants against reference P001 phage of Lactoccocus lactis and F-specific RNA phage MS2 of Escherichia coli in conditions simulating practical use. Similar concentrations of sodium hypochlorite were phagicidal against both bacteriophages, either at 0·05-0·125% of active chlorine using the suspension test or at 0·12-0·5% using the surface test. For Potassium monopersulphate (MPS), phagicidal concentrations varied from 0·006 to 0·012% whatever the type of test and phages. However, for peracetic acid products (PAP) used in suspension, concentrations 55 times higher were necessary against MS2 (0·271%) than against P001 (0·005%). With the surface test, 0·089-0·178% concentrations of PAP were effective against MS2, but these concentrations were 16-32 times greater than needed against P001. Sodium hypochlorite and MPS had similar phagicidal activities against P001 and MS2, but PAP did not. This is the first comparative study to investigate through suspension and surface tests the difference in resistance to peroxy compounds between a reference bacteriophage (P001) used to evaluate phagicidal concentrations in European standards and a surrogate of EVs (MS2). Results underline the importance of validation tests on pertinent surrogates of viruses or bacteriophages to adjust the concentration of disinfectants for use in the food and water industries. © 2015 The Society for Applied Microbiology.

  13. Mechanism of Sporicidal Activity for the Synergistic Combination of Peracetic Acid and Hydrogen Peroxide.

    PubMed

    Leggett, Mark J; Schwarz, J Spencer; Burke, Peter A; McDonnell, Gerald; Denyer, Stephen P; Maillard, Jean-Yves

    2016-02-15

    There is still great interest in controlling bacterial endospores. The use of chemical disinfectants and, notably, oxidizing agents to sterilize medical devices is increasing. With this in mind, hydrogen peroxide (H2O2) and peracetic acid (PAA) have been used in combination, but until now there has been no explanation for the observed increase in sporicidal activity. This study provides information on the mechanism of synergistic interaction of PAA and H2O2 against bacterial spores. We performed investigations of the efficacies of different combinations, including pretreatments with the two oxidizers, against wild-type spores and a range of spore mutants deficient in the spore coat or small acid-soluble spore proteins. The concentrations of the two biocides were also measured in the reaction vessels, enabling the assessment of any shift from H2O2 to PAA formation. This study confirmed the synergistic activity of the combination of H2O2 and PAA. However, we observed that the sporicidal activity of the combination is largely due to PAA and not H2O2. Furthermore, we observed that the synergistic combination was based on H2O2 compromising the spore coat, which was the main spore resistance factor, likely allowing better penetration of PAA and resulting in the increased sporicidal activity. Copyright © 2016 Leggett et al.

  14. Mechanism of Sporicidal Activity for the Synergistic Combination of Peracetic Acid and Hydrogen Peroxide

    PubMed Central

    Leggett, Mark J.; Schwarz, J. Spencer; Burke, Peter A.; McDonnell, Gerald; Denyer, Stephen P.

    2015-01-01

    There is still great interest in controlling bacterial endospores. The use of chemical disinfectants and, notably, oxidizing agents to sterilize medical devices is increasing. With this in mind, hydrogen peroxide (H2O2) and peracetic acid (PAA) have been used in combination, but until now there has been no explanation for the observed increase in sporicidal activity. This study provides information on the mechanism of synergistic interaction of PAA and H2O2 against bacterial spores. We performed investigations of the efficacies of different combinations, including pretreatments with the two oxidizers, against wild-type spores and a range of spore mutants deficient in the spore coat or small acid-soluble spore proteins. The concentrations of the two biocides were also measured in the reaction vessels, enabling the assessment of any shift from H2O2 to PAA formation. This study confirmed the synergistic activity of the combination of H2O2 and PAA. However, we observed that the sporicidal activity of the combination is largely due to PAA and not H2O2. Furthermore, we observed that the synergistic combination was based on H2O2 compromising the spore coat, which was the main spore resistance factor, likely allowing better penetration of PAA and resulting in the increased sporicidal activity. PMID:26637595

  15. Performance Analysis of Exam Gloves Used for Aseptic Rodent Surgery

    PubMed Central

    LeMoine, Dana M; Bergdall, Valerie K; Freed, Carrie

    2015-01-01

    Aseptic technique includes the use of sterile surgical gloves for survival surgeries in rodents to minimize the incidence of infections. Exam gloves are much less expensive than are surgical gloves and may represent a cost-effective, readily available option for use in rodent surgery. This study examined the effectiveness of surface disinfection of exam gloves with 70% isopropyl alcohol or a solution of hydrogen peroxide and peracetic acid (HP–PA) in reducing bacterial contamination. Performance levels for asepsis were met when gloves were negative for bacterial contamination after surface disinfection and sham ‘exertion’ activity. According to these criteria, 94% of HP–PA-disinfected gloves passed, compared with 47% of alcohol-disinfected gloves. In addition, the effect of autoclaving on the integrity of exam gloves was examined, given that autoclaving is another readily available option for aseptic preparation. Performance criteria for glove integrity after autoclaving consisted of: the ability to don the gloves followed by successful simulation of wound closure and completion of stretch tests without tearing or observable defects. Using this criteria, 98% of autoclaved nitrile exam gloves and 76% of autoclaved latex exam gloves met performance expectations compared with the performance of standard surgical gloves (88% nitrile, 100% latex). The results of this study support the use of HP–PA-disinfected latex and nitrile exam gloves or autoclaved nitrile exam gloves as viable cost-effective alternatives to sterile surgical gloves for rodent surgeries. PMID:26045458

  16. Performance analysis of exam gloves used for aseptic rodent surgery.

    PubMed

    LeMoine, Dana M; Bergdall, Valerie K; Freed, Carrie

    2015-05-01

    Aseptic technique includes the use of sterile surgical gloves for survival surgeries in rodents to minimize the incidence of infections. Exam gloves are much less expensive than are surgical gloves and may represent a cost-effective, readily available option for use in rodent surgery. This study examined the effectiveness of surface disinfection of exam gloves with 70% isopropyl alcohol or a solution of hydrogen peroxide and peracetic acid (HP-PA) in reducing bacterial contamination. Performance levels for asepsis were met when gloves were negative for bacterial contamination after surface disinfection and sham 'exertion' activity. According to these criteria, 94% of HP-PA-disinfected gloves passed, compared with 47% of alcohol-disinfected gloves. In addition, the effect of autoclaving on the integrity of exam gloves was examined, given that autoclaving is another readily available option for aseptic preparation. Performance criteria for glove integrity after autoclaving consisted of: the ability to don the gloves followed by successful simulation of wound closure and completion of stretch tests without tearing or observable defects. Using this criteria, 98% of autoclaved nitrile exam gloves and 76% of autoclaved latex exam gloves met performance expectations compared with the performance of standard surgical gloves (88% nitrile, 100% latex). The results of this study support the use of HP-PA-disinfected latex and nitrile exam gloves or autoclaved nitrile exam gloves as viable cost-effective alternatives to sterile surgical gloves for rodent surgeries.

  17. Comparison of hydrogen peroxide and peracetic acid as isolator sterilization agents in a hospital pharmacy.

    PubMed

    Bounoure, Frederic; Fiquet, Herve; Arnaud, Philippe

    2006-03-01

    The efficacy of hydrogen peroxide and peracetic acid as isolator sterilization agents was compared. Sterilization and efficacy tests were conducted in a flexible 0.8-m3 transfer isolator using a standard load of glass bottles and sterile medical devices in their packing paper. Bacillus stearothermophilus spores were placed in six critical locations of the isolator and incubated at 55 degrees C in a culture medium for 14 days. Sterilization by 4.25 mL/m3 of 33% vapor-phase hydrogen peroxide and 12.5 mL/m3 of 3.5% peracetic acid was tested in triplicate. Sterility was validated for hydrogen peroxide and peracetic acid at 60, 90, 120, and 180 minutes and at 90, 120, 150, 180, 210, and 240 minutes, respectively. In an efficacy test conducted with an empty isolator, the sterilization time required to destroy B. stearothermophilus spores was 90 minutes for both sterilants, indicating that they have comparable bactericidal properties. During the validation test with a standard load, the sterilization time using hydrogen peroxide was 150 minutes versus 120 minutes with peracetic acid. The glove cuff was particularly difficult for hydrogen peroxide to sterilize, likely due to its slower diffusion time than that of peracetic acid. Hydrogen peroxide is an environmentally safer agent than peracetic acid; however, its bacteriostatic properties, lack of odor, and poor diffusion time may limit its use in sterilizing some materials. Hydrogen peroxide is a useful alternative to peracetic acid for isolator sterilization in a hospital pharmacy or parenteral nutrition preparation unit.

  18. Tonometer disinfection practice in the United Kingdom: a national survey.

    PubMed

    Hillier, R J; Kumar, N

    2008-08-01

    To assess current tonometer disinfection practice in the UK, and compare with published recommendations. Every ophthalmology unit with training recognition in the UK was contacted (n=155). A senior nurse at each institution completed a telephone questionnaire regarding local tonometer disinfection practice. The response rate was 100%. Thirty-five units (23%) reported exclusive use of disposable tonometer heads and were excluded from further analysis. One hundred and twenty units (77%) used either reusable or a combination of reusable and disposable tonometer heads. Where reusable heads were used, 80 units (67%) immersed them in a chlorine-based solution such as sodium hypochlorite or sodium dichloroisocyanurate. Others used isopropyl alcohol (18 units), hydrogen peroxide (12 units), chloramine (5 units), chlorhexidine (4 units) and peracetic acid (1 unit). Where a chlorine-based agent was used, the concentration of available chlorine ranged from 125 to 30 000 p.p.m., with 50 units (63%) using a concentration of less than 5 000 p.p.m. (i.e., inadequate based on published recommendations). Where the tonometer head was immersed in disinfectant between patients (n=101), 29 units (29%) provided just one tonometer head per practitioner, making adequate soak time between patients unlikely. Every unit replenished the disinfectant at least daily, deemed sufficient for most agents. However, hydrogen peroxide solutions should be replenished twice daily, which did not take place in nine units. This survey reveals disparity between current tonometer disinfection practice and published international recommendations, with some institutions using practices that may render patients susceptible to transmissible infection.

  19. Evaluating a new paradigm for comparing surface disinfection in clinical practice.

    PubMed

    Carling, Philip C; Perkins, Jennifer; Ferguson, JoAnn; Thomasser, Anita

    2014-11-01

    Despite an increasing understanding of the importance of near-patient surfaces in the transmission of healthcare-associated pathogens, there remains a need to define the relative clinical effectiveness of disinfection interventions. A serial 2-phase evaluation of the clinical effectiveness of 2 surface disinfectants. A general acute care hospital. A unique system for quantifying bioburden reduction while monitoring the possible impact of differences in cleaning thoroughness was used to compare the clinical effectiveness of a traditional quaternary ammonium compound (QAC) and a novel peracetic acid/hydrogen peroxide disinfectant (ND) as part of terminal room cleaning. As a result of QAC cleaning, 93 (40%) of 237 cleaned surfaces confirmed by fluorescent marker (DAZO) removal were found to have complete removal of aerobic bioburden. During the ND phase of the study, bioburden was removed from 211 (77%) of 274 cleaned surfaces. Because there was no difference in the thoroughness of cleaning with either disinfectant (65.3% and 66.4%), the significant ([Formula: see text]) difference in bioburden reduction can be attributed to better cleaning efficacy with the ND. In the context of the study design, the ND was 1.93 times more effective in removing bacterial burden than the QAC ([Formula: see text]). Furthermore, the study design represents a new research paradigm in which 2 interventions can be compared by concomitantly and objectively analyzing both the product and process variables in a manner that can be used to define the relative effectiveness of all disinfection cleaning interventions.

  20. Fitness and Recovery of Bacterial Communities and Antibiotic Resistance Genes in Urban Wastewaters Exposed to Classical Disinfection Treatments.

    PubMed

    Di Cesare, Andrea; Fontaneto, Diego; Doppelbauer, Julia; Corno, Gianluca

    2016-09-20

    Antibiotic resistance genes (ARGs) are increasingly appreciated to be important as micropollutants. Indirectly produced by human activities, they are released into the environment, as they are untargeted by conventional wastewater treatments. In order to understand the fate of ARGs and of other resistant forms (e.g., phenotypical adaptations) in urban wastewater treatment plants (WWTPs), we monitored three WWTPs with different disinfection processes (chlorine, peracetic acid (PAA), and ultraviolet light (UV)). We monitored WWTPs influx and pre- and postdisinfection effluent over 24 h, followed by incubation experiments lasting for 96 h. We measured bacterial abundance, size distribution and aggregational behavior, the proportion of intact (active) cells, and the abundances of four ARGs and of the mobile element integron1. While all the predisinfection treatments of all WWTPs removed the majority of bacteria and of associated ARGs, of the disinfection processes only PAA efficiently removed bacterial cells. However, the stress imposed by PAA selected for bacterial aggregates and, similarly to chlorine, stimulated the selection of ARGs during the incubation experiment. This suggests disinfections based on chemically aggressive destruction of bacterial cell structures can promote a residual microbial community that is more resistant to antibiotics and, given the altered aggregational behavior, to competitive stress in nature.

  1. Optimization of strawberry disinfection by fogging of a mixture of peracetic acid and hydrogen peroxide based on microbial reduction, color and phytochemicals retention.

    PubMed

    Van de Velde, Franco; Vaccari, María Celia; Piagentini, Andrea Marcela; Pirovani, María Élida

    2016-09-01

    The fogging of strawberries using a environmentally friendly sanitizer mixture of peracetic acid (5%) and hydrogen peroxide (20%) was performed in a model chamber and modeled as a function of the concentration (3.4, 20.0, 60.0, 100.0 and 116.6 µL sanitizer L(-) (1) air chamber) and the treatment time (5.7, 15.0, 37.5, 60.0 and 69.3 min). The sanitizer fogging was adequate for reducing total mesophilic microbial and yeasts and moulds counts of fruits until seven days of storage at 2℃. However, sanitizer oxidant properties adversely affected the content of total anthocyanins, total phenolics, vitamin C, and antioxidant capacity to various degrees, with some deleterious changes in the fruits color, depending on the fogging conditions. A multiple numeric response optimization was developed based on 2.0 log microbiological reduction, maximum phytochemicals and antioxidant capacity retentions, with no changes in the fruits color, being the optimal fogging conditions achieved: 10.1 µL sanitizer L(-1) air chamber and 29.6 min. The fogging of strawberries at these conditions may represent a promising postharvest treatment option for extending their shelf-life without affecting their sensory quality and bioactive properties. © The Author(s) 2016.

  2. Antimicrobial effect of three disinfecting agents on Resilon cones and their effect on surface topography: An in vitro study

    PubMed Central

    Chandrappa, Mahesh Martur; Meharwade, Prasanna Mahadevasa; Srinivasan, Raghu; Bhandary, Shreetha; Nasreen, Farhat

    2016-01-01

    Aim: The objective of this study was to evaluate the effectiveness of 5.25% sodium hypochlorite (NaOCl), 2% chlorhexidine (CHX), and 2% peracetic acid (PAA) in disinfecting Resilon cones and to evaluate topographical changes microscopically under scanning electron microscope (SEM) after rapid chemical disinfection. Materials and Methods: Resilon cones were disinfected in an ultraviolet (UV) light chamber for 20 min and contaminated by immersing in a microbial suspension of Enterococcus faecalis for 30 min. The contaminated cones were then immersed in the 5.25% NaOCl, 2% CHX, and 2% PAA for 1 min, 5 min, and 10 min, separately. The cones were then incubated at 37°C in thioglycollate broth for 7 days and examined for turbidity. The samples showing turbidity were subcultured on blood agar and incubated at 37°C for 48 h. Gram staining was done to confirm that the cultured bacteria were E. faecalis. Surface changes of disinfected Resilon cones were evaluated under SEM. Statistical Analysis Used: The data were analyzed statistically using Kruskal-Wallis, analysis of variance (ANOVA), and Mann–Whitney U-test. Result: In eliminating E. faecalis, 5.25% NaOCl was most effective followed by 2% PAA and 2% CHX. Topographic examination of tested Resilon cones revealed some surface deposits after disinfection with 5.25% NaOCl and 2% CHX, whereas 2% PAA caused surface erosion. Conclusion: In disinfecting Resilon cones, 5.25% NaOCl is most effective followed by 2% PAA and 2% CHX. PMID:27099418

  3. Alkaline/peracetic acid as a pretreatment of lignocellulosic biomass for ethanol fuel production

    NASA Astrophysics Data System (ADS)

    Teixeira, Lincoln Cambraia

    Peracetic acid is a lignin oxidation pretreatment with low energy input by which biomass can be treated in a silo type system for improving enzymatic digestibility of lignocellulosic materials for ethanol production. Experimentally, ground hybrid poplar wood and sugar cane bagasse are placed in plastic bags and a peracetic acid solution is added to the biomass in different concentrations based on oven-dry biomass. The ratio of solution to biomass is 6:1; after initial mixing of the resulting paste, a seven-day storage period at about 20°C is used in this study. As a complementary method, a series of pre-pretreatments using stoichiometric amounts of sodium hydroxide and ammonium hydroxide based on 4-methyl-glucuronic acid and acetyl content in the biomass is been performed before addition of peracetic acid. The alkaline solutions are added to the biomass in a ratio of 14:1 solution to biomass; the slurry is mixed for 24 hours at ambient temperature. The above procedures give high xylan content substrates. Consequently, xylanase/beta-glucosidase combinations are more effective than cellulase preparations in hydrolyzing these materials. The pretreatment effectiveness is evaluated using standard enzymatic hydrolysis and simultaneous saccharification and cofermentation (SSCF) procedures. Hybrid poplar wood pretreated with 15 and 21% peracetic acid based on oven-dry weight of wood gives glucan conversion yields of 76.5 and 98.3%, respectively. Sugar cane bagasse pretreated with the same loadings gives corresponding yields of 85.9 and 93.1%. Raw wood and raw bagasse give corresponding yields of 6.8 and 28.8%, respectively. The combined 6% NaOH/15% peracetic acid pretreatments increase the glucan conversion yields from 76.5 to 100.0% for hybrid poplar wood and from 85.9 to 97.6% for sugar cane bagasse. Respective ethanol yields of 92.8 and 91.9% are obtained from 6% NaOH/15% peracetic acid pretreated materials using recombinant Zymomonas mobilis CP4/pZB5. Peracetic acid pretreatment improves enzymatic digestibility of hybrid poplar wood and sugar cane bagasse. Based on reduction of acetyl groups in the two lignocellulosic materials, alkaline pre-pretreatments are helpful in reducing peracetic acid requirements in the pretreatment and consequently diminishing growth inhibition of the bacteria that was observed using higher peracetic acid loadings.

  4. Efficacy of disinfectants and detergents intended for a pig farm environment where Salmonella is present.

    PubMed

    Gosling, Rebecca J; Mawhinney, Ian; Vaughan, Kelly; Davies, Robert H; Smith, Richard P

    2017-05-01

    Disinfection is a useful component of disease control, although products and chemical groups vary in their activity against different pathogens. This study investigated the ability of fifteen disinfectants to eliminate pig-associated Salmonella. Active compounds of products included chlorocresol, glutaraldehyde/formaldehyde, glutaraldehyde/quaternary ammonium compounds (QAC), iodine, peracetic acid and potassium peroxomonosulphate. Six detergents were also tested for their ability to dislodge faecal material, and interactions with specific disinfectants. Eight serovars were screened against all products using dilution tests and a monophasic Salmonella Typhimurium strain was selected for further testing. The disinfectants were tested using models to replicate boot dip (faecal suspension) and animal housing (surface contamination) disinfection respectively at the Department for Environment, Food and Rural Affairs Approved Disinfectant General Orders (GO) concentration, half GO and twice GO. Stability over time and ability to eliminate Salmonella in biofilm was also assessed. The most effective products were then field tested. Most products at GO concentration eliminated Salmonella in the faecal suspension model. One glutaraldehyde/QAC and one glutaraldehyde/formaldehyde-based product at GO concentration eliminated Salmonella in the surface contamination model. Chlorocresol-based products were more stable in the faecal suspension model. One chlorocresol and the glutaraldehyde/formaldehyde-based product were most successful in eliminating Salmonella from biofilms. All products tested on farm reduced bacterial log counts; the glutaraldehyde/QAC based product produced the greatest reduction. The type of product and the application concentration can impact on efficacy of farm disinfection; therefore, clearer guidance is needed to ensure the appropriate programmes are used for specific environments. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  5. Electrochemical Disinfection Feasibility Assessment Materials Evaluation for the International Space Station

    NASA Technical Reports Server (NTRS)

    Rodriquez, Branelle; Shindo, David; Montgomery, Eliza

    2013-01-01

    The International Space Station (ISS) Program recognizes the risk of microbial contamination in their potable and non-potable water sources. The end of the Space Shuttle Program limited the ability to send up shock kits of biocides in the event of an outbreak. Currently, the United States Orbital Segment water system relies primarily on iodine to mitigate contamination concerns, which has been successful in remediating the small cases of contamination documented. However, a secondary method of disinfection is a necessary investment for future space flight. Over the past year, NASA Johnson Space Center has investigated the development of electrochemically generated systems for use on the ISS. These systems include: hydrogen peroxide, ozone, sodium hypochlorite, and peracetic acid. To use these biocides on deployed water systems, NASA must understand of the effect these biocides have on current ISS materials prior to proceeding forward with possible on-orbit applications. This paper will discuss the material testing that was conducted to assess the effects of the biocides on current ISS materials.

  6. Comet assay and micronucleus test in circulating erythrocytes of Cyprinus carpio specimens exposed in situ to lake waters treated with disinfectants for potabilization.

    PubMed

    Buschini, A; Martino, A; Gustavino, B; Monfrinotti, M; Poli, P; Rossi, C; Santoro, M; Dörr, A J M; Rizzoni, M

    2004-02-14

    The detection of a possible genotoxic effect of surface water treated with disinfectants for potabilization is the aim of the present work. The Comet assay and the micronucleus test were applied in circulating erythrocytes of Cyprinus carpio. Young specimens (20-30 g) were exposed in experimental basins, built within the potabilization plant of Castiglione del Lago (Perugia, Italy). In this plant the water of the Trasimeno Lake is treated and disinfected for potabilization before it is distributed to the people in the net of drinkable water. A continuous flow of water at a constant rate was supplied to basins; the water was continuously treated at a constant concentration with one of the three tested disinfectants (sodium hypochlorite, peracetic acid and chloride dioxide), one control basin being supplied with untreated water. Three sampling campaigns were performed: October 2000, February 2001 and June 2001. Repeated blood samplings through intracardiac punctures allowed to follow the same fish populations after different exposure times: before introduction of the disinfectant, and 10 or 20 days afterwards. An additional blood sampling was performed 3 h after addition of the disinfectant in other, simultaneously exposed, fish populations. Genotoxic damage was shown in fish exposed to water disinfected with sodium hypochlorite and chloride dioxide. The Comet assay showed an immediate response, i.e. DNA damage that was induced directly in circulating erythrocytes, whereas micronuclei reached their highest frequencies at later sampling times, when a genotoxic damage in stem cells of the cephalic kidney is expressed in circulating erythrocytes. The quality of the untreated surface water seems to be the most important parameter for the long-term DNA damage in circulating erythrocytes.

  7. Biomarkers of end of shift exposure to disinfection byproducts in nurses.

    PubMed

    Ioannou, Solomon; Andrianou, Xanthi D; Charisiadis, Pantelis; Makris, Konstantinos C

    2017-08-01

    Increased disinfectant use commonly takes place in hospitals and other health care settings. A cross-sectional study among active nurses in two Cypriot public hospitals (n=179) was conducted to examine the prevalence of exposure to disinfection byproducts (DBPs), such as trihalomethanes (THMs) using both self-reported information and biomarker measurements. The objectives of this study were to: i) quantify the magnitude and variability of occupational exposure to disinfectants/DBPs in nurses, ii) generate job exposure matrices (JEM) and job task exposure matrices (JTEM) for disinfectants, and iii) assess the major determinants of urinary THMs in nurses. End of shift urinary total THM values showed high variability among the nurses, but did not differ between hospitals. The disinfectant group of alcohols/phenols was used by >98% of nurses, followed by octenidine (82%), iodine and chlorine (39%, each), chlorhexidine (25%), formaldehyde (12%), hydrogen peroxide (11%), and peracetic acid/ammonia/quaternary ammonium compounds (QACs), all being <8% each. Chlorine use during the past 24hr was associated with significantly (p<0.05) lower brominated THMs (BrTHMs) after adjusting for age, gender and BMI, while a positive association was shown for TCM and the sum of all THMs (TTHMs), albeit not significant. Nurses were exposed to nearly double the levels of TTHMs and BrTHMs (median and IQR, 1027 [560, 2475] ng/g and 323 [212, 497] ng/g, respectively) when compared to those of the general population (552 [309,989] ng/g and 152 [87,261] ng/g, respectively). This was the first occupational health dataset reporting measurements of biomarkers of end of shift exposures to disinfectants/DBPs. Copyright © 2017. Published by Elsevier B.V.

  8. Efficacy of Two Peroxygen-Based Disinfectants for Inactivation of Cryptosporidium parvum Oocysts

    PubMed Central

    Quilez, Joaquin; Sanchez-Acedo, Caridad; Avendaño, Catalina; del Cacho, Emilio; Lopez-Bernad, Fernando

    2005-01-01

    Two commercial peroxygen-based disinfectants containing hydrogen peroxide plus either peracetic acid (Ox-Virin) or silver nitrate (Ox-Agua) were tested for their ability to inactivate Cryptosporidium parvum oocysts. Oocysts were obtained from naturally infected goat kids and exposed to concentrations of 2, 5, and 10% Ox-Virin or 1, 3, and 5% Ox-Agua for 30, 60, and 120 min. In vitro excystation, vital dyes (4′,6′-diamidino-2-phenylindole and propidium iodide), and infectivity in neonatal BALB/c mice were used to assess the viability and infectivity of control and disinfectant-treated oocysts. Both disinfectants had a deleterious effect on the survival of C. parvum oocysts, since disinfection significantly reduced and in some cases eliminated their viability and infectivity. When in vitro assays were compared with an infectivity assay as indicators of oocyst inactivation, the excystation assay showed 98.6% inactivation after treatment with 10% Ox-Virin for 60 min, while the vital-dye assay showed 95.2% inactivation and the infectivity assay revealed 100% inactivation. Treatment with 3% Ox-Agua for 30 min completely eliminated oocyst infectivity for mice, although we were able to observe only 74.7% inactivation as measured by excystation assays and 24.3% with vital dyes (which proved to be the least reliable method for predicting C. parvum oocyst viability). These findings indicate the potential efficacy of both disinfectants for C. parvum oocysts in agricultural settings where soil, housing, or tools might be contaminated and support the argument that in comparison to the animal infectivity assay, vital-dye and excystation methods overestimate the viability of oocysts following chemical disinfection. PMID:15870337

  9. Biofilm-forming bacteria with varying tolerance to peracetic acid from a paper machine.

    PubMed

    Rasimus, Stiina; Kolari, Marko; Rita, Hannu; Hoornstra, Douwe; Salkinoja-Salonen, Mirja

    2011-09-01

    Biofilms cause runnability problems in paper machines and are therefore controlled with biocides. Peracetic acid is usually effective in preventing bulky biofilms. This study investigated the microbiological status of a paper machine where low concentrations (≤ 15 ppm active ingredient) of peracetic acid had been used for several years. The paper machine contained a low amount of biofilms. Biofilm-forming bacteria from this environment were isolated and characterized by 16S rRNA gene sequencing, whole-cell fatty acid analysis, biochemical tests, and DNA fingerprinting. Seventy-five percent of the isolates were identified as members of the subclades Sphingomonas trueperi and S. aquatilis, and the others as species of the genera Burkholderia (B. cepacia complex), Methylobacterium, and Rhizobium. Although the isolation media were suitable for the common paper machine biofoulers Deinococcus, Meiothermus, and Pseudoxanthomonas, none of these were found, indicating that peracetic acid had prevented their growth. Spontaneous, irreversible loss of the ability to form biofilm was observed during subculturing of certain isolates of the subclade S. trueperi. The Sphingomonas isolates formed monoculture biofilms that tolerated peracetic acid at concentrations (10 ppm active ingredient) used for antifouling in paper machines. High pH and low conductivity of the process waters favored the peracetic acid tolerance of Sphingomonas sp. biofilms. This appears to be the first report on sphingomonads as biofilm formers in warm water using industries.

  10. Variability of Listeria monocytogenes strains in biofilm formation on stainless steel and polystyrene materials and resistance to peracetic acid and quaternary ammonium compounds.

    PubMed

    Poimenidou, Sofia V; Chrysadakou, Marilena; Tzakoniati, Aikaterini; Bikouli, Vasiliki C; Nychas, George-John; Skandamis, Panagiotis N

    2016-11-21

    Listeria monocytogenes is a foodborne pathogen able to tolerate adverse conditions by forming biofilms or by deploying stress resistant mechanisms, and thus manages to survive for long periods in food processing plants. This study sought to investigate the correlation between biofilm forming ability, tolerance to disinfectants and cell surface characteristics of twelve L. monocytogenes strains. The following attributes were evaluated: (i) biofilm formation by crystal violet staining method on polystyrene, and by standard cell enumeration on stainless steel and polystyrene; (ii) hydrophobicity assay using solvents; (iii) minimum inhibitory concentration (MIC) and biofilm eradication concentration (BEC) of peracetic acid (PAA) and quaternary ammonium compounds (QACs), and (iv) resistance to sanitizers (PAA 2000ppm; QACs 500ppm) of biofilms on polystyrene and stainless steel. After 72h of incubation, higher biofilm levels were formed in TSB at 20°C, followed by TSB at 37°C (P=0.087) and diluted TSB 1/10 at both 20 (P=0.005) and 37°C (P=0.004). Cells grown at 30°C to the stationary phase had significant electron donating nature and a low hydrophobicity, while no significant correlation of cell surface properties to biofilm formation was observed. Strains differed in MIC PAA and BEC PAA by 24- and 15-fold, respectively, while a positive correlation between MIC PAA and BEC PAA was observed (P=0.02). The MIC QACs was positively correlated with the biofilm-forming ability on stainless steel (P=0.03). Regarding the impact of surface type, higher biofilm populations were enumerated on polystyrene than on stainless steel, which were also more tolerant to disinfectants. Among all strains, the greatest biofilm producer was a persistent strain with significant tolerance to QACs. These results may contribute to better understanding of L. monocytogenes behavior and survival on food processing surfaces. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Assaying the Stability and Inactivation of AAV Serotype 1 Vectors

    PubMed Central

    Howard, Douglas B.; Harvey, Brandon K.

    2017-01-01

    Adeno-associated virus (AAV) vectors are a commonplace tool for gene delivery ranging from cell culture to human gene therapy. One feature that makes AAV a desirable vector is its stability, in regard to both the duration of transgene expression and retention of infectivity as a viral particle. This study examined the stability of AAV serotype 1 (AAV1) vectors under different conditions. First, transducibility after storage at 4°C decreased 20% over 7 weeks. Over 10 freeze–thaw cycles, the resulting transduction efficiency became variable at 60–120% of a single thaw. Using small stainless steel slugs to mimic a biosafety cabinet or metal lab bench surface, it was found that an AAV1 vector can be reconstituted after 6 days of storage at room temperature. The stability of AAV is a desired feature, but effective decontamination procedures must be available for safety and experimental integrity. Multiple disinfectants commonly used in the laboratory for ability to inactivate an AAV1 vector were tested, and it was found that autoclaving, 0.25% peracetic acid, iodine, or 10% Clorox bleach completely prevented AAV-mediated transgene expression. These data suggest that peracetic acid should be used for inactivating AAV1 vectors on metal-based surfaces or instruments in order to avoid inadvertent transgene expression in human cells or cross-contamination of instruments. PMID:28192678

  12. Increased saccharification yields from aspen biomass upon treatment with enzymatically generated peracetic acid.

    PubMed

    Duncan, Shona; Jing, Qing; Katona, Adrian; Kazlauskas, Romas J; Schilling, Jonathan; Tschirner, Ulrike; Aldajani, Waleed Wafa

    2010-03-01

    The recalcitrance of lignocellulosic biomass to enzymatic release of sugars (saccharification) currently limits its use as feedstock for biofuels. Enzymatic hydrolysis of untreated aspen wood releases only 21.8% of the available sugars due primarily to the lignin barrier. Nature uses oxidative enzymes to selectively degrade lignin in lignocellulosic biomass, but thus far, natural enzymes have been too slow for industrial use. In this study, oxidative pretreatment with commercial peracetic acid (470 mM) removed 40% of the lignin (from 19.9 to 12.0 wt.% lignin) from aspen and enhanced the sugar yields in subsequent enzymatic hydrolysis to about 90%. Increasing the amount of lignin removed correlated with increasing yields of sugar release. Unfortunately, peracetic acid is expensive, and concentrated forms can be hazardous. To reduce costs and hazards associated with using commercial peracetic acid, we used a hydrolase to catalyze the perhydrolysis of ethyl acetate generating 60-70 mM peracetic acid in situ as a pretreatment to remove lignin from aspen wood. A single pretreatment was insufficient, but multiple cycles (up to eight) removed up to 61.7% of the lignin enabling release of >90% of the sugars during saccharification. This value corresponds to a predicted 581 g of fermentable sugars from 1 kg of aspen wood. Improvements in the enzyme stability are needed before the enzymatically generated peracetic acid is a commercially viable alternative.

  13. [Effect on the microbicidal efficacy of formaldehyde, glutardialdehyde, peracetic acid, chloramine T (N-chloro-4-toluenesulfonamide), m-cresol, ethanol and benzyldimethyldodecacylammonium bromide by blood (model experiments for chemical disinfection of instruments)].

    PubMed

    Spicher, G; Peters, J

    1998-02-01

    In a preceding paper (Zbl. Hyg. 191 [1991] 457-477) we reported on the dependence of the microbicidal efficacy of active agents of the disinfection of instruments on the amount of coagulated blood adhering to the instruments. In the present investigation, we were interested in the dependence of the microbicidal effects on the amount of blood in the solutions of the active agents. Test areas of 2 cm2 were contaminated with 50 and 100 microliters coagulating blood, respectively, containing cells of Staphylococcus aureus as test germ. The solutions of the microbicidal agents were contaminated with heparinized blood up to a concentration of 4% immediately before starting the disinfection and 24 hours before, respectively. After a period of action lasting 1 hour at 20 degrees C, the relative number of test germs capable of multiplying (N/N0) was determined. The concentration of the microbicidal substances reducing the relative number of test germs capable to multiply to 10(-4) served for estimating the dependence of the microbicidal efficacy of the agents on the blood content of the solutions. The experimental results depended on the thickness of the layer of coagulated blood. The dependence of the efficacy of the microbicidal substances on the blood content of the solutions was the higher the thinner the blood layer was. At a thickness of the layer of the coagulated blood of 0.25 mm, a blood content of the solution of 4%, and applying it immediately after adding the blood, the concentration of glutardialdehyde had to be 1.6 times that without blood to reach the same microbicidal efficacy. When applying the solution 24 hours after adding the blood, the concentration of glutardialdehyde had to be 4.2 times that without blood. The quaternary ammonium compound reacted faster with the blood than did glutardialdehyde; the respective factors were 2.6 and 4.5. The concentration factors of chloramine T were 3.3 and 3.8. Under the conditions of the test, peracetic acid exhibited small concentration factors: 1.3 and 1.6. The microbicidal efficacy of ethanol, formaldehyde and m-cresol soap solution was not or only slightly altered by the amount of blood in the solution of the microbicidal agent.

  14. Effectiveness of current disinfection procedures against biofilm on contaminated GI endoscopes.

    PubMed

    Neves, Marcelo S; da Silva, Marlei Gomes; Ventura, Grasiella M; Côrtes, Patrícia Barbur; Duarte, Rafael Silva; de Souza, Heitor S

    2016-05-01

    Attention to patient safety has increased recently due to outbreaks of nosocomial infections associated with GI endoscopy. The aim of this study was to evaluate current cleaning and disinfection procedures of endoscope channels with high bioburden and biofilm analysis, including the use of resistant mycobacteria associated with postsurgical infections in Brazil. Twenty-seven original endoscope channels were contaminated with organic soil containing 10(8) colony-forming units/mL of Pseudomonas aeruginosa, Staphylococcus aureus, or Mycobacterium abscessus subsp bolletii. Biofilms with the same microorganisms were developed on the inner surface of channels with the initial inoculum of 10(5) colony-forming units/mL. Channels were reprocessed following current protocol, and samples from cleaning and disinfection steps were analyzed by bioluminescence for adenosine triphosphate, cultures for viable microorganisms, and confocal microscopy. After contamination, adenosine triphosphate levels increased dramatically, and high bacterial growth was observed in all cultures. After cleaning, adenosine triphosphate levels decreased to values comparable to precontamination levels, and bacterial growth was demonstrated in 5 of 27 catheters, 2 with P aeruginosa and 3 with M abscessus. With regard to induced biofilm, a remarkable reduction occurred after cleaning, but significant microbial growth inhibition occurred only after disinfection. Nevertheless, viable microorganisms within the biofilm were still detected by confocal microscopy, more so with glutaraldehyde than with peracetic acid or O-phataladehyde. After the complete disinfection procedure, viable microorganisms could still be detected within the biofilm on endoscope channels. Prevention of biofilm development within endoscope channels should be a priority in disinfection procedures, particularly for ERCP and EUS. Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  15. Bactericidal active ingredient in cryopreserved plasma-treated water with the reduced-pH method for plasma disinfection

    NASA Astrophysics Data System (ADS)

    Kitano, Katsuhisa; Ikawa, Satoshi; Nakashima, Yoichi; Tani, Atsushi; Yokoyama, Takashi; Ohshima, Tomoko

    2016-09-01

    For the plasma disinfection of human body, plasma sterilization in liquid is crucial. We found that the plasma-treated water (PTW) has strong bactericidal activity under low pH condition. Physicochemical properties of PTW is discussed based on chemical kinetics. Lower temperature brings longer half-life and the bactericidal activity of PTW can be kept by cryopreservation. High performance PTW, corresponding to the disinfection power of 22 log reduction (B. subtilis spore), can be obtained by special plasma system equipped with cooling device. This is equivalent to 65% H2O2, 14% sodium hypochlorite and 0.33% peracetic acid, which are deadly poison for human. But, it is deactivated soon at higher temperature (4 sec. at body temperature), and toxicity to human body seems low. For dental application, PTW was effective on infected models of human extracted tooth. Although PTW has many chemical components, respective chemical components in PTW were isolated by ion chromatography. In addition to peaks of H2O2, NO2- and NO3-, a specific peak was detected. and only this fraction had bactericidal activity. Purified active ingredient of PTW is the precursor of HOO, and further details will be discussed in the presentation. MEXT (15H03583, 23340176, 25108505). NCCE (23-A-15).

  16. Methodological proposal for validation of the disinfecting efficacy of an automated flexible endoscope reprocessor

    PubMed Central

    Graziano, Kazuko Uchikawa; Pereira, Marta Elisa Auler; Koda, Elaine

    2016-01-01

    ABSTRACT Objective: to elaborate and apply a method to assess the efficacy of automated flexible endoscope reprocessors at a time when there is not an official method or trained laboratories to comply with the requirements described in specific standards for this type of health product in Brazil. Method: the present methodological study was developed based on the following theoretical references: International Organization for Standardization (ISO) standard ISO 15883-4/2008 and Brazilian Health Surveillance Agency (Agência Nacional de Vigilância Sanitária - ANVISA) Collegiate Board Resolution (Resolução de Diretoria Colegiada - RDC) no. 35/2010 and 15/2012. The proposed method was applied to a commercially available device using a high-level 0.2% peracetic acid-based disinfectant. Results: the proposed method of assessment was found to be robust when the recommendations made in the relevant legislation were incorporated with some adjustments to ensure their feasibility. Application of the proposed method provided evidence of the efficacy of the tested equipment for the high-level disinfection of endoscopes. Conclusion: the proposed method may serve as a reference for the assessment of flexible endoscope reprocessors, thereby providing solid ground for the purchase of this category of health products. PMID:27508915

  17. Resistance of Acanthamoeba Cysts to Disinfection Treatments Used in Health Care Settings▿

    PubMed Central

    Coulon, Céline; Collignon, Anne; McDonnell, Gerald; Thomas, Vincent

    2010-01-01

    Free-living amoebae that belong to the genus Acanthamoeba are widespread in the environment, including water. They are responsible for human infections and can host pathogenic microorganisms. Under unfavorable conditions, they form cysts with high levels of resistance to disinfection methods, thus potentially representing a threat to public health. In the present study we evaluated the efficacies of various biocides against trophozoites and cysts of several Acanthamoeba strains. We demonstrated that disinfectant efficacy varied depending on the strains tested, with environmental strains demonstrating greater resistance than collection strains. Trophozoites were inactivated by all treatments except those using glutaraldehyde as an active compound: for these treatments, we observed resistance even after 30 min exposure. Cysts resisted many treatments, including certain conditions with glutaraldehyde and other biocides. Moist heat at 55°C was not efficient against cysts, whereas exposure at 65°C was. Several chemical formulations containing peracetic acid, hydrogen peroxide, or ortho-phthalaldehyde presented greater efficacy than glutaraldehyde, as did ethanol and sodium hypochlorite; however, some of these treatments required relatively long incubation times to achieve cyst inactivation. Amoebal cysts can be highly resistant to some high-level disinfectants, which has implications for clinical practice. These results highlight the need to consider the effective disinfection of protozoa in their vegetative and resistant forms due to their intrinsic resistance. This is important not only to prevent the transmission of protozoa themselves but also due to the risks associated with a range of microbial pathogens that are found to be associated intracellularly with these microorganisms. PMID:20519477

  18. A high-throughput microtiter plate based method for the determination of peracetic acid and hydrogen peroxide.

    PubMed

    Putt, Karson S; Pugh, Randall B

    2013-01-01

    Peracetic acid is gaining usage in numerous industries who have found a myriad of uses for its antimicrobial activity. However, rapid high throughput quantitation methods for peracetic acid and hydrogen peroxide are lacking. Herein, we describe the development of a high-throughput microtiter plate based assay based upon the well known and trusted titration chemical reactions. The adaptation of these titration chemistries to rapid plate based absorbance methods for the sequential determination of hydrogen peroxide specifically and the total amount of peroxides present in solution are described. The results of these methods were compared to those of a standard titration and found to be in good agreement. Additionally, the utility of the developed method is demonstrated through the generation of degradation curves of both peracetic acid and hydrogen peroxide in a mixed solution.

  19. Influence of peracetic acid modification on the physicochemical properties of activated carbon and its performance in the ozone-catalytic oxidation of gaseous benzene

    NASA Astrophysics Data System (ADS)

    Fang, Ruimei; Huang, Haibao; Huang, Wenjun; Ji, Jian; Feng, Qiuyu; Shu, Yajie; Zhan, Yujie; Liu, Gaoyuan; Xie, Ruijie

    2017-10-01

    Coal based activated carbon (AC) was pretreated by peracetic acid solution and used for supporting Mn catalyst towards oxidation of gaseous benzene by catalytic ozonation. The as-obtained activated carbon was characterized by XPS, BET, SEM, and TG technologies. It indicates that peracetic acid solution modification not only raised the quantity of chemisorbed oxygen or water, and hydroxyl group on activated carbon material surface, but also increased the specific surface area and benzene adsorption capacity of activated carbon. Benzene could be completely removed in 300 min and CO2 selectivity reached to 61.9% over Mn/AC-modified catalyst. A possible catalytic ozonation mechanism of activated carbon which was treated by peracetic acid solution supported Mn catalyst for oxidation of benzene was proposed.

  20. A High-Throughput Microtiter Plate Based Method for the Determination of Peracetic Acid and Hydrogen Peroxide

    PubMed Central

    Putt, Karson S.; Pugh, Randall B.

    2013-01-01

    Peracetic acid is gaining usage in numerous industries who have found a myriad of uses for its antimicrobial activity. However, rapid high throughput quantitation methods for peracetic acid and hydrogen peroxide are lacking. Herein, we describe the development of a high-throughput microtiter plate based assay based upon the well known and trusted titration chemical reactions. The adaptation of these titration chemistries to rapid plate based absorbance methods for the sequential determination of hydrogen peroxide specifically and the total amount of peroxides present in solution are described. The results of these methods were compared to those of a standard titration and found to be in good agreement. Additionally, the utility of the developed method is demonstrated through the generation of degradation curves of both peracetic acid and hydrogen peroxide in a mixed solution. PMID:24260173

  1. Validating the efficacy of peracetic acid mixture as an antimicrobial in poultry chillers.

    PubMed

    Bauermeister, Laura J; Bowers, Jordan W J; Townsend, Julie C; McKee, Shelly R

    2008-06-01

    Peracetic acid mixture (PAHP), which is a combination of peracetic acid and hydrogen peroxide, has been approved as an antimicrobial for use in poultry chillers. To validate its effectiveness, 85 ppm of PAHP was compared with the 30-ppm chlorine treatment in a commercial setting. In this trial, 100 carcasses were sampled for Salmonella and Campylobacter spp. prior to chilling and 100 carcasses were sampled after chilling. In all, 400 carcasses were sampled using 85 ppm of PAHP in the chiller and 400 carcasses were sampled using the chlorine treatment. PAHP at 85 ppm reduced Salmonella-positive carcasses by 92% exiting the chiller, whereas treatment with 30 ppm of chlorine reduced Salmonella by 57%. Additionally, PAHP reduced Campylobacter species-positive carcasses exiting the chiller by 43% while chlorine resulted in a 13% reduction. These results suggest that peracetic acid in combination with hydrogen peroxide may be an effective antimicrobial in poultry chiller applications.

  2. One-step pretreatment of yellow poplar biomass using peracetic acid to enhance enzymatic digestibility.

    PubMed

    Lee, Hyeong Rae; Kazlauskas, Romas J; Park, Tai Hyun

    2017-09-22

    Pretreatment of biomass with dilute acid requires high temperatures of >160 °C to remove xylan and does not remove lignin. Here we report that the addition of peracetic acid, a strong oxidant, to mild dilute acid pretreatment reduces the temperature requirement to only 120 °C. Pretreatment of yellow poplar with peracetic acid (300 mM, 2.3 wt%) and dilute sulfuric acid (100 mM, 1.0 wt%) at 120 °C for 5 min removed 85.7% of the xylan and 90.4% of the lignin leaving a solid consisting of 75.6% glucan, 6.0% xylan and 4.7% lignin. Low enzyme loadings of 5 FPU/g glucan and 10 pNPGU/g glucan converted this solid to glucose with an 84.0% yield. This amount of glucose was 2.5 times higher than with dilute acid-pretreated solid and 13.8 times higher than with untreated yellow poplar. Thus, the addition of peracetic acid, easily generated from acetic acid and hydrogen peroxide, dramatically increases the effectiveness of dilute acid pretreatment of biomass.

  3. Oxidation of β-lactam antibiotics by peracetic acid: Reaction kinetics, product and pathway evaluation.

    PubMed

    Zhang, Kejia; Zhou, Xinyan; Du, Penghui; Zhang, Tuqiao; Cai, Meiquan; Sun, Peizhe; Huang, Ching-Hua

    2017-10-15

    Peracetic acid (PAA) is a disinfection oxidant used in many industries including wastewater treatment. β-Lactams, a group of widely prescribed antibiotics, are frequently detected in wastewater effluents and surface waters. The reaction kinetics and transformation of seven β-lactams (cefalexin (CFX), cefadroxil (CFR), cefapirin (CFP), cephalothin (CFT), ampicillin (AMP), amoxicillin (AMX) and penicillin G (PG)) toward PAA were investigated to elucidate the behavior of β-lactams during PAA oxidation processes. The reaction follows second-order kinetics and is much faster at pH 5 and 7 than at pH 9 due to speciation of PAA. Reactivity to PAA follows the order of CFR ∼ CFX > AMP ∼ AMX > CFT ∼ CFP ∼ PG and is related to β-lactam's nucleophilicity. The thioether sulfur of β-lactams is attacked by PAA to generate sulfoxide products. Presence of the phenylglycinyl amino group on β-lactams can significantly influence electron distribution and the highest occupied molecular orbital (HOMO) location and energy in ways that enhance the reactivity to PAA. Reaction rate constants obtained in clean water matrix can be used to accurately model the decay of β-lactams by PAA in surface water matrix and only slightly overestimate the decay in wastewater matrix. Results of this study indicate that the oxidative transformation of β-lactams by PAA can be expected under appropriate wastewater treatment conditions. Copyright © 2017. Published by Elsevier Ltd.

  4. Surgical infection in a videolaparoscopic cholecystectomy when using peracetic acid for the sterilization of instruments.

    PubMed

    de Melo, Edluza Maria Viana Bezerra; Leão, Cristiano de Souza; Andreto, Luciana Marques; de Mello, Maria Júlia Gonçalves

    2013-01-01

    To determine the frequency of surgical site infection in patients undergoing laparoscopic cholecystectomy with instruments sterilized by peracetic acid. We conducted a retrospective, cohort, descriptive, cross-sectional study. Peracetic acid has been used for sterilization following the protocol recommended by the manufacturer. We observed the criteria and indicators of process and structure for preventing surgical site infection pre and intraoperatively. For epidemiological surveillance, outpatient visits were scheduled for the 15th and between the 30th and 45th days after discharge. Among the 247 patients, there were two cases of surgical site infection (0.8%). One patient was readmitted to systemic antibiotic therapy and percutaneous puncture; in the other the infection was superficial and followed at the clinic. Ethical issues prevent the conduction of a prospective study because of peracetic acid have been banned for the sterilization of instruments that penetrate organs and cavities. Nevertheless, these results encourage prospective case-control studies comparing its use (historical control) with ethylene oxide sterilization.

  5. [The activity of formaldehyde, glutardialdehyde, peracetic acid, chloramine T (N-chlor-4-toluolsulfonamide), m-cresol, ethanol and benzyldimethyldodecylammonium bromide against bacteria which are found in coagulated blood. (Model studies for chemical disinfection of instruments].

    PubMed

    Spicher, G; Peters, J

    1991-05-01

    The experiments were performed using frosted glass as carrier with its surface being contaminated with whole blood containing Staphylococcus aureus as test organism. At the time of sampling, a heparin preparation was added to the blood to prevent premature coagulation. After addition of the staphylococci, coagulation was initiated by means of a heparin antagonist. 10, 25, 50, 100, and 150 microliters, respectively, of the blood were homogeneously spread on rectangular test areas of 10 x 20 mm. After the blood had coagulated, each of the test objects was placed in 15 ml of the solution (20 degrees C) containing the active ingredient tested for 60 min. After that, the test objects were removed from the disinfectant and, in order to inactivate any adhering active components, treated with a neutralizing solution of suitable composition. The number of viable germs (colony-forming units) was determined quantitatively. The blood samples were ground together with quartz sand. Aliquots of the diluted suspensions were mixed with molten agar medium. The plates then were incubated at 37 degrees C over a period of 14 days. The relative number of viable germs (N/No) per test object was calculated from the number of colonies. Plotting of the microbicidal effects obtained (log N/No] versus the concentration of the active substance (see Figs. 1-3) yielded curves differing in some characteristics as e.g. curvature, slope of the lower curve section (log N/No). less than -3), concentration range according to the layer thickness of the contamination. To visualize the reduction of the efficacy of the respective disinfectants caused by blood, the concentrations of active components were determined which are necessary to achieve a microbicidal effect of log (N/No) = -4. These concentrations were plotted versus the amounts of blood per test area (Fig. 4). The resulting curve for formaldehyde was slightly U-shaped. With a raising amount of blood, the concentration required slightly decreased in the beginning and increased again from an amount of ca. 100 microliter blood per test area. For all other active substances, the required concentration of these substances increased with the amount of blood used. The curve obtained for ethanol exhibited the lowest slope. The slope of the curves increased in the following order: ethanol, m-cresol, peracetic acid, chloramine T, glutardialdehyde, benzyldimethyldodecylammoniumbromide. The curves for chloramine T and glutardialdehyde nearly paralleled each other.(ABSTRACT TRUNCATED AT 400 WORDS)

  6. Precautionary Practices of Healthcare Workers Who Disinfect Medical and Dental Devices Using High-Level Disinfectants

    PubMed Central

    Henn, Scott A.; Boiano, James M.; Steege, Andrea L.

    2016-01-01

    Background High-level disinfectants (HLDs) are used throughout the healthcare industry to chemically disinfect reusable, semicritical medical and dental devices to control and prevent healthcare-associated infections among patient populations. Workers who use HLDs are at risk of exposure to these chemicals, some of which are respiratory and skin irritants and sensitizers. Objective To evaluate exposure controls used and to better understand impediments to healthcare workers using personal protective equipment while handling HLDs. Design Web-based survey. Participants A targeted sample of members of professional practice organizations representing nurses, technologists/technicians, dental professionals, respiratory therapists, and others who reported handling HLDs in the previous 7 calendar days. Participating organizations invited either all or a random sample of members via email, which included a hyperlink to the survey. Methods Descriptive analyses were conducted including simple frequencies and prevalences. Results A total of 4,657 respondents completed the survey. The HLDs used most often were glutaraldehyde (59%), peracetic acid (16%), and ortho-phthalaldehyde (15%). Examples of work practices or events that could increase exposure risk included failure to wear water-resistant gowns (44%); absence of standard procedures for minimizing exposure (19%); lack of safe handling training (17%); failure to wear protective gloves (9%); and a spill/leak of HLD during handling (5%). Among all respondents, 12% reported skin contact with HLDs, and 33% of these respondents reported that they did not always wear gloves. Conclusion Findings indicated that precautionary practices were not always used, underscoring the importance of improved employer and worker training and education regarding HLD hazards. PMID:25633000

  7. Effects of disinfectants in renal dialysis patients.

    PubMed Central

    Klein, E

    1986-01-01

    Patients receiving hemodialysis therapy risk exposure to both disinfectants and sterilants. Dialysis equipment is disinfected periodically with strong solutions of hypochlorite or formaldehyde. More recently, reuse of dialyzers has introduced the use of additional sterilants, such as hydrogen peroxide and peracetic acid. The use of these sterilants is recognized by the center staffs and the home patient as a potential risk, and residue tests are carried out for the presence of these sterilants at the ppm level. Gross hemolysis resulting from accidental hypochlorite infusion has led to cardiac arrest, probably as a result of hyperkalemia. Formaldehyde is commonly used in 4% solutions to sterilize the fluid paths of dialysis controllers and to sterilize dialyzers before reuse. It can react with red cell antigenic surfaces leading to the formation of anti-N antibodies. Such reactions probably do not occur with hypochlorite or chloramines. The major exposure risk is the low concentration of disinfectant found in municipal water used to prepare 450 L dialysate weekly. With thrice-weekly treatment schedules, the quality requirements for water used to make this solution must be met rigorously. Standards for water used in the preparation of dialysate have recently been proposed but not all patients are treated with dialysate meeting such standards. The introduction of sterilants via tap water is insidious and has led to more pervasive consequences. Both chlorine and chloramines, at concentrations found in potable water, are strong oxidants that cause extensive protein denaturation and hemolysis. Oxidation of the Fe2+ in hemoglobin to Fe3+ forms methemoglobin, which is incapable of carrying either O2 or CO2.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:3816735

  8. Efficacy of detergents and fresh produce disinfectants against microorganisms associated with mixed raw vegetables.

    PubMed

    Samadi, Nasrin; Abadian, Neda; Bakhtiari, Donya; Fazeli, Mohammad Reza; Jamalifar, Hossein

    2009-07-01

    Efficacy of commercial detergent and disinfectants to eliminate microorganisms associated with fresh vegetables eaten raw in Iran, including radish, parsley, basil, coriander (cilantro), Allium porrum (leek), and peppermint were studied. The raw vegetables were subjected to a triple wash treatment of washing in tap water for mud removal, washing in water containing a detergent (dishwashing liquid) or disinfectant individually, and rinsing in tap water. The population of total mesophilic microbes on the surface of untreated vegetables ranged from 10(5) to 10(6) CFU/g. Washing in tap water or treatment with detergent (333 ppm for 10 min) or benzalkonium chloride (92 ppm for 15 min) reduced the total microbial count, most probable number (MPN) of coliforms, MPN of fecal coliforms, and MPN of fecal streptococci by about 1.2 to 2.3 log. No significant differences in microbial populations were found on vegetables after decontamination with tap water, detergent, or benzalkonium chloride (P > 0.05). Treatments with peracetic acid (100 ppm for 15 min) and hydrogen peroxide (133 ppm for 30 min) reduced the total mesophilic microbial counts by about 2.8 log. The microbial reductions with calcium hypochlorite (300 ppm for 15 min) and combined hydrogen peroxide and silver ion (133 ppm for 30 min) were significantly higher than those obtained after rinsing in tap water or after detergent or benzalkonium chloride wash (P < 0.05). Pretreatment with detergent slightly enhanced the efficacy of all decontamination treatments, but results were not significantly different from those obtained after individual application of disinfectants.

  9. The effect of copper sulfate, potassium permanganate, and peracetic acid on Ichthyobodo necator in channel catfish

    USDA-ARS?s Scientific Manuscript database

    Ichthyobodo necator is a single celled biflagellate that can cause significant mortalities in fish, particularly young, tank-reared fish. Copper sulfate (CuSO4), potassium permanganate (KMnO4) and peracetic acid (PAA) were evaluated for effectiveness against Ichthybodosis in juvenile channel catfis...

  10. Comparison of the toxicity of the peracetic acid formulations Wofasteril(c) E400, E250 and Lspez to Daphnia magna with emphasis on the effect of hydrogen peroxide

    USDA-ARS?s Scientific Manuscript database

    Commercial peracetic acid (PAA) formulations are acidic mixtures of PAA, hydrogen peroxide (H2O2), acetic acid (AA), H2O and stabilizers to maintain equilibrium of the concentrations. Different PAA formulations show diverse PAA/H2O2 ratios, leading to potentially different toxicities at the same con...

  11. Sporicidal Activity of the KMT reagent in its vapor phase against Geobacillus stearothermophilus Spores.

    PubMed

    Kida, Nori; Mochizuki, Yasushi; Taguchi, Fumiaki

    2007-01-01

    In an investigation of the sporicidal activity of the KMT reagent, a vapor phase study was performed using five kinds of carriers contaminated with Geobacillus stearothermophilus spores. When 25 ml of the KMT reagent was vaporized in a chamber (capacity; approximately 95 liters), the 2-step heating method (vaporization by a combination of low temperature and high temperature) showed the most effective sporicidal activity in comparison with the 1-step heating method (rapid vaporization). The 2-step heating method appeared to be related to the sporicidal activity of vaporized KMT reagent, i.e., ethanol and iodine, which vaporized mainly when heated at a low temperature such as 55 C, and acidic water, which vaporized mainly when heated at a high temperature such as 300 C. We proposed that the KMT reagent can be used as a new disinfectant not only in the liquid phase but also in the vapor phase in the same way as peracetic acid and hydrogen peroxide.

  12. Assessment of a colorimetric method for the measurement of low concentrations of peracetic acid and hydrogen peroxide in water.

    PubMed

    Domínguez-Henao, Laura; Turolla, Andrea; Monticelli, Damiano; Antonelli, Manuela

    2018-06-01

    The recent growing interest in peracetic acid (PAA) as disinfectant for wastewater treatment demands reliable and readily-available methods for its measurement. In detail, the monitoring of PAA in wastewater treatment plants requires a simple, accurate, rapid and inexpensive measurement procedure. In the present work, a method for analyzing low concentrations of PAA, adapted from the US EPA colorimetric method for total chlorine, is assessed. This method employs N,N-diethyl-p-phenylelnediamine (DPD) in the presence of an excess of iodide in a phosphate buffer system. Pink colored species are produced proportionally to the concentration of PAA in the sample. Considering that PAA is available commercially as an equilibrium solution of PAA and hydrogen peroxide (H 2 O 2 ), a measurement method for H 2 O 2 is also investigated. This method, as the one for the determination of PAA, is also based on the oxidation of iodide to iodine, with the difference that ammonium molybdate Mo(VI) is added to catalyze the oxidation reaction between H 2 O 2 and iodide, quantifying the total peroxides (PAA+ H 2 O 2 ). The two methods are suitable for concentration ranges from about 0.1-1.65 mg L -1 and from about 0.3-3.3 mg L -1 , respectively for PAA and H 2 O 2 . Moreover, the work elucidates some relevant aspects related to the operational conditions, kinetics and the possible interference of H 2 O 2 on PAA measurement. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Behavior of Listeria monocytogenes in a multi-species biofilm with Enterococcus faecalis and Enterococcus faecium and control through sanitation procedures.

    PubMed

    da Silva Fernandes, Meg; Kabuki, Dirce Yorika; Kuaye, Arnaldo Yoshiteru

    2015-05-04

    The formation of mono-species biofilm (Listeria monocytogenes) and multi-species biofilms (Enterococcus faecium, Enterococcus faecalis, and L. monocytogenes) was evaluated. In addition, the effectiveness of sanitation procedures for the control of the multi-species biofilm also was evaluated. The biofilms were grown on stainless steel coupons at various incubation temperatures (7, 25 and 39°C) and contact times (0, 1, 2, 4, 6 and 8 days). In all tests, at 7°C, the microbial counts were below 0.4 log CFU/cm(2) and not characteristic of biofilms. In mono-species biofilm, the counts of L. monocytogenes after 8 days of contact were 4.1 and 2.8 log CFU/cm(2) at 25 and 39°C, respectively. In the multi-species biofilms, Enterococcus spp. were present at counts of 8 log CFU/cm(2) at 25 and 39°C after 8 days of contact. However, the L. monocytogenes in multi-species biofilms was significantly affected by the presence of Enterococcus spp. and by temperature. At 25°C, the growth of L. monocytogenes biofilms was favored in multi-species cultures, with counts above 6 log CFU/cm(2) after 8 days of contact. In contrast, at 39°C, a negative effect was observed for L. monocytogenes biofilm growth in mixed cultures, with a significant reduction in counts over time and values below 0.4 log CFU/cm(2) starting at day 4. Anionic tensioactive cleaning complemented with another procedure (acid cleaning, disinfection or acid cleaning+disinfection) eliminated the multi-species biofilms under all conditions tested (counts of all micro-organisms<0.4 log CFU/cm(2)). Peracetic acid was the most effective disinfectant, eliminating the multi-species biofilms under all tested conditions (counts of the all microorganisms <0.4 log CFU/cm(2)). In contrast, biguanide was the least effective disinfectant, failing to eliminate biofilms under all the test conditions. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Evaluation of continuous 4 day exposure to peracetic acid as a treatment for Ichthyophthirius multifiliis

    USDA-ARS?s Scientific Manuscript database

    The parasitic ciliate Ichthyophthirius multifiliis infests all species of freshwater fish and can cause severe economic losses in fish breeding. The most effective treatment, malachite green, has been banned in Europe and North America for use in food-fish production. Peracetic acid (PAA) was foun...

  15. The Relationship of Intestinal Bacteria and Diet Composition to Amino Acid Requirements of White Mice

    DTIC Science & Technology

    1975-02-01

    alkyl lauryl sulfate added as a wet^ng agent. Routine sterilization of air locks and material entering the isolators was done with 2.OX peracetic...flexible plastic isolators of the Trexler type (19). The isolators were sterilized with 4.0% peracetic acid in water with a small amount of sodium

  16. Evaluation of an automated room decontamination device using aerosolized peracetic acid.

    PubMed

    Mana, Thriveen S C; Sitzlar, Brett; Cadnum, Jennifer L; Jencson, Annette L; Koganti, Sreelatha; Donskey, Curtis J

    2017-03-01

    Because manual cleaning is often suboptimal, there is increasing interest in use of automated devices for room decontamination. We demonstrated that an ultrasonic room fogging system that generates submicron droplets of peracetic acid and hydrogen peroxide eliminated Clostridium difficile spores and vegetative pathogens from exposed carriers in hospital rooms and adjacent bathrooms. Published by Elsevier Inc.

  17. Use of copper sulfate and peracetic acid as therapeutants on fish: can these replace formalin?

    USDA-ARS?s Scientific Manuscript database

    Copper sulfate (CuSO4) and peracetic acid (PAA) are compounds that have been found to be useful in several areas of aquaculture around the world. In the United States, CuSO4 is used for treatment of an ectoparasite (Ichthyophthirius multifiliis) on fish (Straus 1993; Tieman and Goodwin 2001), and s...

  18. Efficacy of Lactic Acid, Lactic Acid-Acetic Acid Blends, and Peracetic Acid To Reduce Salmonella on Chicken Parts under Simulated Commercial Processing Conditions.

    PubMed

    Ramirez-Hernandez, Alejandra; Brashears, Mindy M; Sanchez-Plata, Marcos X

    2018-01-01

    The poultry processing industry has been undergoing a series of changes as it modifies processing practices to comply with new performance standards for chicken parts and comminuted poultry products. The regulatory approach encourages the use of intervention strategies to prevent and control foodborne pathogens in poultry products and thus improve food safety and protect human health. The present studies were conducted to evaluate the efficacy of antimicrobial interventions for reducing Salmonella on inoculated chicken parts under simulated commercial processing conditions. Chicken pieces were inoculated by immersion in a five-strain Salmonella cocktail at 6 log CFU/mL and then treated with organic acids and oxidizing agents on a commercial rinsing conveyor belt. The efficacy of spraying with six different treatments (sterile water, lactic acid, acetic acid, buffered lactic acid, acetic acid in combination with lactic acid, and peracetic acid) at two concentrations was evaluated on skin-on and skin-off chicken thighs at three application temperatures. Skinless chicken breasts were used to evaluate the antimicrobial efficacy of lactic acid and peracetic acid. The color stability of treated and untreated chicken parts was assessed after the acid interventions. The lactic acid and buffered lactic acid treatments produced the greatest reductions in Salmonella counts. Significant differences between the control and water treatments were identified for 5.11% lactic acid and 5.85% buffered lactic acid in both skin-on and skin-off chicken thighs. No significant effect of treatment temperature for skin-on chicken thighs was found. Lactic acid and peracetic acid were effective agents for eluting Salmonella cells attached to chicken breasts.

  19. inhibitory effects of citral, cinnamaldehyde, and tea polyphenols on mixed biofilm formation by foodborne Staphylococcus aureus and Salmonella enteritidis.

    PubMed

    Zhang, Hongmei; Zhou, Wenyuan; Zhang, Wenyan; Yang, Anlin; Liu, Yanlan; Jiang, Yan; Huang, Shaosong; Su, Jianyu

    2014-06-01

    Biofilms are significant hazards in the food industry. In this study, we investigated the effects of food additive such as citral, cinnamaldehyde, and tea polyphenols on mixed biofilm formation by foodborne Staphylococcus aureus and Salmonella serotype Enteritidis. The adhesion rates of mixed strains in sub-MIC of additives were determined by a microtiter plate assay and bacterial communication signal autoinducer 2 (AI-2) production via a bioluminescence reporter Vibrio harveyi BB170. The structure of mixed biofilm was analyzed using scanning electron microscopy. The effect of the disinfectants hydrogen peroxide, sodium hypochlorite, and peracetic acid was tested on the mixed biofilm. Our results demonstrated that citral, cinnamaldehyde, and tea polyphenols were able to significantly inhibit mixed biofilm formation, while citral could reduce the synthesis of AI-2. Conversely, we observed a significant increase in AI-2 mediated by cinnamaldehyde. Tea polyphenols at lower concentrations induced AI-2 synthesis; however, AI-2 synthesis was significantly inhibited at higher concentrations (300 m g/ml). Food additives inhibited the adhesion of mixed bacteria on stainless steel chips and increased the sensitivity of the mixed biofilm to disinfectants. In conclusion, citral, cinnamaldehyde, and tea polyphenols had strong inhibitory effects on mixed biofilm formation and also enhanced the effect of disinfectant on mixed biofilm formation. This study provides a scientific basis for the application of natural food additives to control biofilm formation of foodborne bacteria.

  20. Experimental evaluation of an automated endoscope reprocessor with in situ generation of peracetic acid for disinfection of semicritical devices.

    PubMed

    Sattar, Syed A; Kibbee, Richard J; Tetro, Jason A; Rook, Tony A

    2006-11-01

    To evaluate the effectiveness of a high-level disinfection solution generated inside an endoscope processing system for decontaminating external and internal surfaces of experimentally contaminated heat-sensitive medical devices. The American Society for Testing and Materials Simulated-Use Test protocol (E1837-02), which incorporates a soil load in each inoculum, was used to evaluate the efficacy of the system when processing 4 common types of endoscopes contaminated separately with 5 types of nosocomial pathogens: Pseudomonas aeruginosa (ATCC 15442), spores of Clostridium difficile (ATCC 9689), a glutaraldehyde-resistant strain of Mycobacterium chelonae, a vancomycin-resistant strain of Enterococcus faecalis, and a methicillin-resistant strain of Staphylococcus aureus. Rinse solution samples from channels and from surfaces of the processed endoscopes were tested for any microbicidal residues. For all organisms tested, the baseline level of contamination of the endoscopes ranged from 5 log(10) to greater than 7 log(10) at each external surface site and internal channel. All tests showed reductions in viability of the test organisms to undetectable levels. All rinse solution samples from external and internal sites of the endoscopes proved to be free of any residual microbicidal activity. The endoscope reprocessor, with its processor-generated high-level disinfection solution, successfully reduced the numbers of selected, clinically relevant pathogens to undetectable levels both in the channels and on the outside surfaces of the 4 representative endoscopes tested in this study.

  1. Optimization of human tendon tissue engineering: peracetic acid oxidation for enhanced reseeding of acellularized intrasynovial tendon.

    PubMed

    Woon, Colin Y L; Pridgen, Brian C; Kraus, Armin; Bari, Sina; Pham, Hung; Chang, James

    2011-03-01

    Tissue engineering of human flexor tendons combines tendon scaffolds with recipient cells to create complete cell-tendon constructs. Allogenic acellularized human flexor tendon has been shown to be a useful natural scaffold. However, there is difficulty repopulating acellularized tendon with recipient cells, as cell penetration is restricted by a tightly woven tendon matrix. The authors evaluated peracetic acid treatment in optimizing intratendinous cell penetration. Cadaveric human flexor tendons were harvested, acellularized, and divided into experimental groups. These groups were treated with peracetic acid in varying concentrations (2%, 5%, and 10%) and for varying time periods (4 and 20 hours) to determine the optimal treatment protocol. Experimental tendons were analyzed for differences in tendon microarchitecture. Additional specimens were reseeded by incubation in a fibroblast cell suspension at 1 × 10(6) cells/ml. This group was then analyzed for reseeding efficacy. A final group underwent biomechanical studies for strength. The optimal treatment protocol comprising peracetic acid at 5% concentration for 4 hours produced increased scaffold porosity, improving cell penetration and migration. Treated scaffolds did not show reduced collagen or glycosaminoglycan content compared with controls (p = 0.37 and p = 0.65, respectively). Treated scaffolds were cytotoxic to neither attached cells nor the surrounding cell suspension. Treated scaffolds also did not show inferior ultimate tensile stress or elastic modulus compared with controls (p = 0.26 and p = 0.28, respectively). Peracetic acid treatment of acellularized tendon scaffolds increases matrix porosity, leading to greater reseeding. It may prove to be an important step in tissue engineering of human flexor tendon using natural scaffolds.

  2. Effectiveness of copper sulfate, potassium permanganate, and peracetic acid to reduce mortality and infestation of Ichthyobodo nector in channel catfish Ictalurus punctatus (Rafinesque 1818)

    USDA-ARS?s Scientific Manuscript database

    Ichthyobodo necator is a single celled bi-flagellate parasite, and in high density can causes significant mortality in young fish. Copper sulfate (CuSO4), potassium permanganate (KMnO4) and peracetic acid (PAA) were evaluated for effectiveness against ichthyobodosis. Treatments were: untreated con...

  3. Efficacy of sodium hypochlorite and peracetic acid in sanitizing green coconuts.

    PubMed

    Walter, E H M; Nascimento, M S; Kuaye, A Y

    2009-09-01

    To evaluate the efficacy of sanitizing green coconuts (Cocos nucifera L.) through the treatment applied by juice industries using sodium hypochlorite and peracetic acid. The surface of the fruits was inoculated with a mixture of five Listeria monocytogenes strains. The treatments consisted in immersing the fruits for 2 min at room temperature in sodium hypochlorite solution containing 200 mg l(-1) residual chlorine at pH 6.5, and 80 mg l(-1) solution of peracetic acid or sterile water. Bacterial populations were quantified by culturing on trypticase soy agar supplemented with yeast extract and Oxford selective culture medium; however, recovery was higher on the nonselective medium. Immersion in water produced a reduction in the L. monocytogenes population of 1.7 log(10) CFU per fruit, while immersion in sodium hypochlorite and peracetic acid solutions resulted in population reductions of 2.7 and 4.7 log(10) CFU per fruit respectively. The treatments studied are efficient to green coconuts. Sanitation of green coconut is one of the most important control measures to prevent the contamination of coconut water. This article provides information that shows the adequacy of sanitizing treatments applied by the juice industries.

  4. Contamination sources, serogroups, biofilm-forming ability and biocide resistance of Listeria monocytogenes persistent in tilapia-processing facilities.

    PubMed

    Vázquez-Sánchez, Daniel; Galvão, Juliana Antunes; Oetterer, Marília

    2017-11-01

    The major contamination sources, serogroups, biofilm-forming ability and biocide resistance of Listeria monocytogenes persistent in tilapia-processing facilities were assessed. Twenty-five processing-control points were examined twice in two factories, including whole tilapias, frozen fillets, water and food-contact surfaces. L. monocytogenes were detected in 4 and 20% of points of Factory A and B respectively, but at low concentrations. Contamination was due to inadequate handling of tilapias in the slaughter room of Factory A and to the application of ineffective sanitizing procedures in Factory B. Seven strains were characterized by RAPD-PCR using primers HLWL85, OPM-01 and DAF4. Genotypic similarity allowed tracing the contamination source of tilapia fillets in Factory B and detecting a prevalent strain in Brazilian tilapia-processing facilities. The serogroup II (including the serotype 1/2c) was the most frequently found, followed by serogroup I (1/2a) and III (1/2b), whereas the serotype 4b was not detected. All strains showed high biofilm-forming ability on stainless steel and polystyrene, but biofilm formation was positively correlated with the type of origin surface. Biofilms were highly resistant to peracetic acid and sodium hypochlorite, being required doses higher than those recommended by manufacturers to be eradicated. Peracetic acid was more effective than sodium hypochlorite, but the use of disinfectants with similar mechanisms of action increases the risk of cross-resistance. Case-by-case approaches are thus recommended to determine the sources and degree of contamination present in each factory, which would allow applying precise responses to control the persistence of bacterial pathogens such as L. monocytogenes .

  5. Decontamination of Bacillus spores adhered to iron and cement-mortar drinking water infrastructure in a model system using disinfectants.

    PubMed

    Szabo, Jeffrey G; Meiners, Greg; Heckman, Lee; Rice, Eugene W; Hall, John

    2017-02-01

    Decontamination of Bacillus spores adhered to common drinking water infrastructure surfaces was evaluated using a variety of disinfectants. Corroded iron and cement-mortar lined iron represented the infrastructure surfaces, and were conditioned in a 23 m long, 15 cm diameter (75 ft long, 6 in diameter) pilot-scale drinking water distribution pipe system. Decontamination was evaluated using increased water velocity (flushing) alone at 0.5 m s -1 (1.7 ft s -1 ), as well as free chlorine (5 and 25 mg L -1 ), monochloramine (25 mg L -1 ), chlorine dioxide (5 and 25 mg L -1 ), ozone (2.0 mg L -1 ), peracetic acid 25 mg L -1 ) and acidified nitrite (0.1 mol L -1 at pH 2 and 3), all followed by flushing at 0.3 m s -1 (1 ft s -1 ). Flushing alone reduced the adhered spores by 0.5 and 2.0 log 10 from iron and cement-mortar, respectively. Log 10 reduction on corroded iron pipe wall coupons ranged from 1.0 to 2.9 at respective chlorine dioxide concentrations of 5 and 25 mg L -1 , although spores were undetectable on the iron surface during disinfection at 25 mg L -1 . Acidified nitrite (pH 2, 0.1 mol L -1 ) yielded no detectable spores on the iron surface during the flushing phase after disinfection. Chlorine dioxide was the best performing disinfectant with >3.0 log 10 removal from cement-mortar at 5 and 25 mg L -1 . The data show that free chlorine, monochloramine, ozone and chlorine dioxide followed by flushing can reduce adhered spores by > 3.0 log 10 on cement-mortar. Published by Elsevier Ltd.

  6. Effect of Peracetic Acid as A Final Rinse on Push Out Bond Strength of Root Canal Sealers to Root Dentin.

    PubMed

    Gaddala, Naresh; Veeramachineni, Chandrasekhar; Tummala, Muralidhar

    2015-05-01

    Smear layer which was formed during the instrumentation of root canals hinders the penetration of root canal sealers to root dentin and affect the bond strength of root canal sealers to root dentin. Final irrigant such as demineralizing agents are used to remove the inorganic portion of the smear layer. In the present study, peracetic acid used as a final rinse, to effect the bond strength of root canal sealers to root dentin. The purpose of the present study was to evaluate the efficacy of peracetic acid as a final irrigant on bond strength of root canal sealers to root dentin. Sixty six freshly extracted human single rooted mandibular premolars were used for this study. After decoronation the samples were instrumented with Protaper upto F3 and irrigated with 5.25% NaOcl. The teeth were then divided into three groups based on final irrigant used: Group-1(control group) Canals were irrigated with distilled water. Group-2: Canals were irrigated with peracetic acid. Group-3: Canals were irrigated with smear clear. Each group was further divided into three subgroups (n=30) based on the sealer used to obturate the canals. Subgroup-1: kerr, Subgroup-2: Apexit plus, Subgroup-3: AH PLUS. Each sealer was mixed and coated to master cone and placed in the canal. The bonding between sealer and dentin surface was evaluated using push out bond strength by universal testing machine. The mean bond strength values of each group were statistically evaluated using Two-way ANOVA followed by Tukey post-hoc test. Significant difference was found among the bond strength of the sealers. But, there is no statistically significant difference between the groups irrigated with peracetic acid and smear clear compared to control group. AH Plus showed highest bond strength irrespective of the final irrigant used. Peracetic acid when employed as final irrigant improved the bond strength of root canal sealers compared to control group but not statistically significant than smear clear.

  7. Effect of Peracetic Acid as A Final Rinse on Push Out Bond Strength of Root Canal Sealers to Root Dentin

    PubMed Central

    Gaddala, Naresh; Veeramachineni, Chandrasekhar

    2015-01-01

    Background Smear layer which was formed during the instrumentation of root canals hinders the penetration of root canal sealers to root dentin and affect the bond strength of root canal sealers to root dentin. Final irrigant such as demineralizing agents are used to remove the inorganic portion of the smear layer. In the present study, peracetic acid used as a final rinse, to effect the bond strength of root canal sealers to root dentin. Aim The purpose of the present study was to evaluate the efficacy of peracetic acid as a final irrigant on bond strength of root canal sealers to root dentin. Materials and Methods Sixty six freshly extracted human single rooted mandibular premolars were used for this study. After decoronation the samples were instrumented with Protaper upto F3 and irrigated with 5.25% NaOcl. The teeth were then divided into three groups based on final irrigant used: Group-1(control group) Canals were irrigated with distilled water. Group-2: Canals were irrigated with peracetic acid. Group-3: Canals were irrigated with smear clear. Each group was further divided into three subgroups (n=30) based on the sealer used to obturate the canals. Subgroup-1: kerr, Subgroup-2: Apexit plus, Subgroup-3: AH PLUS. Each sealer was mixed and coated to master cone and placed in the canal. The bonding between sealer and dentin surface was evaluated using push out bond strength by universal testing machine. The mean bond strength values of each group were statistically evaluated using Two-way ANOVA followed by Tukey post-hoc test. Results Significant difference was found among the bond strength of the sealers. But, there is no statistically significant difference between the groups irrigated with peracetic acid and smear clear compared to control group. AH Plus showed highest bond strength irrespective of the final irrigant used. Conclusion Peracetic acid when employed as final irrigant improved the bond strength of root canal sealers compared to control group but not statistically significant than smear clear. PMID:26155568

  8. Modulation of cytochrome P450 and induction of DNA damage in Cyprinus carpio exposed in situ to surface water treated with chlorine or alternative disinfectants in different seasons.

    PubMed

    Canistro, Donatella; Melega, Simone; Ranieri, Dario; Sapone, Andrea; Gustavino, Bianca; Monfrinotti, Monica; Rizzoni, Marco; Paolini, Moreno

    2012-01-03

    Epidemiological studies have shown an association between consumption of disinfected drinking water and adverse health outcomes. The chemicals used to disinfect water react with occurring organic matter and anthropogenic contaminants in the source water, resulting in the formation of disinfection by-products (DBPs). The observations that some DBPs are carcinogenic in animal models have raised public concern over the possible adverse health effects for humans. Here, the modulation of liver cytochrome P450-linked monooxygenases (MFO) and the genotoxic effects in erythrocytes of Cyprinus carpio fish exposed in situ to surface drinking water in the presence of disinfectants, such as sodium hypochlorite (NaClO), chlorine dioxide (ClO(2)) and peracetic acid (PAA), were investigated in winter and summer. A complex induction/suppression pattern of CYP-associated MFOs in winter was observed for all disinfectants. For example, a 3.4- to 15-fold increase was recorded of the CYP2B1/2-linked dealkylation of penthoxyresorufin with NaClO (10 days) and PAA (20 days). In contrast, ClO(2) generated the most notable inactivation, the CYP2E1-supported hydroxylation of p-nitrophenol being decreased up to 71% after 10 days' treatment. In summer, the degree of modulation was modest, with the exception of CYP3A1/2 and CYP1A1 supported MFOs (62% loss after 20 days PAA). The micronucleus (MN) induction in fish circulating erythrocytes was also analysed as an endpoint of genotoxic potential in the same fish population. Significant increases of MN induction were detected at the latest sampling time on fish exposed to surface water treated with chlorinate-disinfectants, both in winter (NaClO) and summer (NaClO and ClO(2)), while no effect was observed in fish exposed to PAA-treated water. These results show that water disinfection may be responsible for harmful outcomes in terms of MFO perturbation and DNA damage; if extrapolated to humans, they ultimately offer a possible rationale for the increased urinary cancer risk recorded in regular drinking water consumers. Copyright © 2011 Elsevier B.V. All rights reserved.

  9. Omics approaches on fresh-cut lettuce reveal global molecular responses to sodium hypochlorite and peracetic acid treatment.

    PubMed

    Daddiego, Loretta; Bianco, Linda; Capodicasa, Cristina; Carbone, Fabrizio; Dalmastri, Claudia; Daroda, Lorenza; Del Fiore, Antonella; De Rossi, Patrizia; Di Carli, Mariasole; Donini, Marcello; Lopez, Loredana; Mengoni, Alessio; Paganin, Patrizia; Perrotta, Gaetano; Bevivino, Annamaria

    2018-01-01

    Lettuce is a leafy vegetable that is extensively commercialized as a ready-to-eat product because of its widespread use in human nutrition as salad. It is well known that washing treatments can severely affect the quality and shelf-life of ready-to-eat vegetables. The study presented here evaluated the effect of two washing procedures on fresh-cut lettuce during storage. An omics approach was applied to reveal global changes at molecular level induced by peracetic acid washing in comparison with sodium hypochlorite treatment. Microbiological analyses were also performed to quantify total bacterial abundance and composition. The study revealed wide metabolic alterations induced by the two sanitizers. In particular, transcriptomic and proteomic analyses pointed out a number of transcripts and proteins differentially accumulated in response to peracetic acid washing, mainly occurring on the first day of storage. In parallel, different microbiota composition and significant reduction in total bacterial load following washing were also observed. The results provide useful information for the fresh-cut industry to select an appropriate washing procedure preserving fresh-like attributes as much as possible during storage of the end product. Molecular evidence indicated peracetic acid to be a valid alternative to sodium hypochlorite as sanitizer solution. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  10. A comparative study on the effectiveness of ozonated water and peracetic acid in the storability of packaged fresh-cut melon.

    PubMed

    Botondi, Rinaldo; Moscetti, Roberto; Massantini, Riccardo

    2016-05-01

    Ozonated water and peracetic acid were tested as sanitizers to enhance the storability of fresh-cut melon cubes. Sanitizers were also combined with suitable packaging materials (polypropylene and polylactic acid based plastic films). Fresh-cut melon cubes were stored at 4 °C for up to 7 days. Ozonated water and peracetic acid treatments were given by dipping cubes into 0.8 ppm O3 and 100 ppm Tsunami 100™ solutions, respectively, for 3 min. Both sanitizers exhibited efficiency in reducing the total microbial counts on melon cubes (< 2 log CFU g(-1)). Respiratory activity and ethylene production were both affected by the interaction between the sanitizer and the packaging used. Carbon dioxide and oxygen reached 9.89 kPa and 12.20 kPa partial pressures, respectively, using peracetic acid treatment in combination with polypropylene film packaging, consequently developing off-odors starting from day 3. Strong color changes were noted in cubes stored in polylactic acid packaging after 7 days of storage, affecting the sensory quality of the melon cubes. Sensory evaluation (overall visual quality) indicated loss in flavor in the polypropylene packaging. The overall visual quality started to decline on 3rd day because of the development of translucency.Overall, the use of ozone in combination with polypropylene packaging provided the best solution to maintain the quality of melon cubes for up to 5 days of storage at 4 °C.

  11. Ultrasound improves chemical reduction of natural contaminant microbiota and Salmonella enterica subsp. enterica on strawberries.

    PubMed

    do Rosário, Denes Kaic Alves; da Silva Mutz, Yhan; Peixoto, Jaqueline Moreira Curtis; Oliveira, Syllas Borburema Silva; de Carvalho, Raquel Vieira; Carneiro, Joel Camilo Souza; de São José, Jackline Freitas Brilhante; Bernardes, Patrícia Campos

    2017-01-16

    New sanitization methods have been evaluated to improve food safety and food quality and to replace chlorine compounds. However, these new methods can lead to physicochemical and sensory changes in fruits and vegetables. The present study evaluated the effects of acetic acid, peracetic acid, and sodium dodecylbenzenesulfonate isolated or combined with 5min of ultrasound treatment (40kHz, 500W) on strawberry quality over 9days of storage at 8°C. The strawberry natural contaminant microbiota (molds and yeasts, mesophilic aerobic and lactic acid bacteria), physicochemical quality (pH, total titratable acidity, total soluble solids, vitamin C, and color), sensory quality (triangle test) and inactivation of Salmonella enterica subsp. enterica intentionally inoculated onto strawberries were analyzed. Ultrasound increased the effect of all chemical compounds in the reduction of aerobic mesophilic, molds and yeasts. The best treatment for those groups of microorganisms was ultrasound combined with peracetic acid (US+PA) that reduced 1.8 and 2.0logcfu/g during 9days of storage. Bactericidal effect of peracetic acid was also improved by ultrasound inactivation of S. enterica, reaching a decimal reduction of 2.1logcfu/g. Moreover, synergistic effects were observed in contaminant natural microbiota inactivation for all tested compounds during storage, without any major physicochemical or sensory alteration to the strawberries. Therefore, ultrasound treatment can improve the effect of sanitizers that are substitutes of chlorine compounds without altering the quality of strawberries during storage. Acetic acid (PubChem CID: 176); Peracetic acid (PubChem CID: 6585); Sodium dodecylbenzenesulfonate (PubChem CID: 18372154). Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Efficiency of hydrogen peroxide in improving disinfection of ICU rooms.

    PubMed

    Blazejewski, Caroline; Wallet, Frédéric; Rouzé, Anahita; Le Guern, Rémi; Ponthieux, Sylvie; Salleron, Julia; Nseir, Saad

    2015-02-02

    The primary objective of this study was to determine the efficiency of hydrogen peroxide (H₂O₂) techniques in disinfection of ICU rooms contaminated with multidrug-resistant organisms (MDRO) after patient discharge. Secondary objectives included comparison of the efficiency of a vaporizator (HPV, Bioquell) and an aerosolizer using H₂O₂, and peracetic acid (aHPP, Anios) in MDRO environmental disinfection, and assessment of toxicity of these techniques. This prospective cross-over study was conducted in five medical and surgical ICUs located in one University hospital, during a 12-week period. Routine terminal cleaning was followed by H₂O₂ disinfection. A total of 24 environmental bacteriological samplings were collected per room, from eight frequently touched surfaces, at three time-points: after patient discharge (T0), after terminal cleaning (T1) and after H₂O₂ disinfection (T2). In total 182 rooms were studied, including 89 (49%) disinfected with aHPP and 93 (51%) with HPV. At T0, 15/182 (8%) rooms were contaminated with at least 1 MDRO (extended spectrum β-lactamase-producing Gram-negative bacilli 50%, imipenem resistant Acinetobacter baumannii 29%, methicillin-resistant Staphylococcus aureus 17%, and Pseudomonas aeruginosa resistant to ceftazidime or imipenem 4%). Routine terminal cleaning reduced environmental bacterial load (P <0.001) without efficiency on MDRO (15/182 (8%) rooms at T0 versus 11/182 (6%) at T1; P = 0.371). H₂O₂ technologies were efficient for environmental MDRO decontamination (6% of rooms contaminated with MDRO at T1 versus 0.5% at T2, P = 0.004). Patient characteristics were similar in aHPP and HPV groups. No significant difference was found between aHPP and HPV regarding the rate of rooms contaminated with MDRO at T2 (P = 0.313). 42% of room occupants were MDRO carriers. The highest rate of rooms contaminated with MDRO was found in rooms where patients stayed for a longer period of time, and where a patient with MDRO was hospitalized. The residual concentration of H₂O₂ appears to be higher using aHPP, compared with HPV. H₂O₂ treatment is efficient in reducing MDRO contaminated rooms in the ICU. No significant difference was found between aHPP and HPV regarding their disinfection efficiency.

  13. Supercritical carbon dioxide-based sterilization of decellularized heart valves.

    PubMed

    Hennessy, Ryan S; Jana, Soumen; Tefft, Brandon J; Helder, Meghana R; Young, Melissa D; Hennessy, Rebecca R; Stoyles, Nicholas J; Lerman, Amir

    2017-02-01

    The goal of this research project encompasses finding the most efficient and effective method of decellularized tissue sterilization. Aortic tissue grafts have been utilized to repair damaged or diseased valves. Although, the tissues for grafting are collected aseptically, it does not eradicate the risk of contamination nor disease transfer. Thus, sterilization of grafts is mandatory. Several techniques have been applied to sterilize grafts; however, each technique shows drawbacks. In this study, we compared several sterilization techniques: supercritical carbon dioxide, electrolyzed water, gamma radiation, ethanol-peracetic acid, and hydrogen peroxide for impact on the sterility and mechanical integrity of porcine decellularized aortic valves. Valve sterility was characterized by histology, microbe culture, and electron microscopy. Uniaxial tensile testing was conducted on the valve cusps along their circumferential orientation to study these sterilization techniques on their integrity. Ethanol-peracetic acid and supercritical carbon dioxide treated valves were found to be sterile. The tensile strength of supercritical carbon dioxide treated valves (4.28 ± 0.22 MPa) was higher to those valves treated with electrolyzed water, gamma radiation, ethanol-peracetic acid and hydrogen peroxide (1.02 ± 0.15, 1.25 ± 0.25, 3.53 ± 0.41 and 0.37 ± 0.04 MPa, respectively). Superior sterility and integrity were found in the decellularized porcine aortic valves with supercritical carbon dioxide sterilization. This sterilization technique may hold promise for other decellularized soft tissues. Sterilization of grafts is essential. Supercritical carbon dioxide, electrolyzed water, gamma radiation, ethanol-peracetic acid, and hydrogen peroxide techniques were compared for impact on sterility and mechanical integrity of porcine decellularized aortic valves. Ethanol-peracetic acid and supercritical carbon dioxide treated valves were found to be sterile using histology, microbe culture and electron microscopy assays. The cusp tensile properties of supercritical carbon dioxide treated valves were higher compared to valves treated with other techniques. Superior sterility and integrity was found in the decellularized valves treated with supercritical carbon dioxide sterilization. This sterilization technique may hold promise for other decellularized soft tissues.

  14. Development of a large-scale isolation chamber system for the safe and humane care of medium-sized laboratory animals harboring infectious diseases*

    PubMed Central

    Pan, Xin; Qi, Jian-cheng; Long, Ming; Liang, Hao; Chen, Xiao; Li, Han; Li, Guang-bo; Zheng, Hao

    2010-01-01

    The close phylogenetic relationship between humans and non-human primates makes non-human primates an irreplaceable model for the study of human infectious diseases. In this study, we describe the development of a large-scale automatic multi-functional isolation chamber for use with medium-sized laboratory animals carrying infectious diseases. The isolation chamber, including the transfer chain, disinfection chain, negative air pressure isolation system, animal welfare system, and the automated system, is designed to meet all biological safety standards. To create an internal chamber environment that is completely isolated from the exterior, variable frequency drive blowers are used in the air-intake and air-exhaust system, precisely controlling the filtered air flow and providing an air-barrier protection. A double door transfer port is used to transfer material between the interior of the isolation chamber and the outside. A peracetic acid sterilizer and its associated pipeline allow for complete disinfection of the isolation chamber. All of the isolation chamber parameters can be automatically controlled by a programmable computerized menu, allowing for work with different animals in different-sized cages depending on the research project. The large-scale multi-functional isolation chamber provides a useful and safe system for working with infectious medium-sized laboratory animals in high-level bio-safety laboratories. PMID:20872984

  15. In vitro assessment of the chemotherapeutic action of a specific hydrogen peroxide, peracetic, acetic, and peroctanoic acid-based formulation against the free-living stages of Ichthyophthirius multifiliis (Ciliophora).

    PubMed

    Picón-Camacho, Sara M; Marcos-Lopez, Mar; Beljean, Alexandre; Debeaume, Sylvain; Shinn, Andrew P

    2012-02-01

    Traditionally, malachite green administrated as in-bath treatment was the most effective and common strategy used in freshwater aquaculture systems to control infections of the ciliate protozoan parasite Ichthyophthirius multifiliis Fouquet, 1876. After the ban of malachite green in the USA and Europe to be used in fish for human consumption, there has been extensive research destined to find efficacious replacements. Recently, peracetic acid-based compounds have demonstrated a strong cytotoxic effect in vitro and in vivo against I. multifiliis. In the present study, we tested the efficacy of a hydrogen peroxide, peracetic, acetic and peroctanoic acid-based formulation (HPPAPA) to eliminate the free-living stages of I. multifiliis (tomonts, cysts and theronts). The results obtained showed that the administration of low doses (8, 12 or 15 mg/l) of a specific HPPAPA-based product during a short window of exposure (60 min) kills nearly all free-living stages of I. multifiliis (theronts, tomonts and cysts) within the window of treatment (∼100% mortality for all the stages; one-way ANOVA, P ≤ 0.001). Of note, even the lowest concentration of HPPAPA tested (8 mg/l) was able to disrupt normal cyst development and therefore theront release. The demonstrated in vitro efficacy of the peracetic acid-based product tested on the present study suggests its great potential to control I. multifiliis infections in commercial aquacultural systems.

  16. A 5 year longitudinal study of water quality for final rinsing in the single chamber washer-disinfector with a reverse osmosis plant.

    PubMed

    Uetera, Yushi; Kishii, Kozue; Yasuhara, Hiroshi; Kumada, Naohito; Moriya, Kyoji; Saito, Ryoichi; Okazaki, Mitsuhiro; Misawa, Yoshiki; Kawamura, Kunio

    2013-01-01

    This report deals with the construction and management of the reverse osmosis (RO) water system for final rinsing of surgical instruments in the washer-disinfector. Numerous operational challenges were encountered in our RO water system and these were analyzed utilizing the Ishikawa Fishbone diagram. The aim was to find potential problems and promote preventive system management for RO water. It was found that the measures that existed were inappropriate for preventing contamination in the heat-labile RO water system. The storage tank was found to be significantly contaminated and had to be replaced with a new one equipped with a sampling port and water drainage system. Additional filters and an UV treatment lamp were installed. The whole system disinfection started 1.5 years later using a peracetic acid-based compound after confirming the material compatibility. Operator errors were found when a new water engineer took over the duty from his predecessor. It was also found that there were some deficiencies in the standard operating procedures (SOPs), and that on-the-job training was not enough. The water engineer failed to disinfect the sampling port and water drainage system. The RO membrane had been used for 4 years, even though the SOP standard specified changing it as every 3 years. Various bacteria, such as Rothia mucilaginosa, were cultured from the RO water sampled from the equipment. Because Rothia mucilaginosa is a resident in the oral cavity and upper respiratory tract, it is believed that the bacteria were introduced into the system by the maintenance personnel or working environment. Therefore, the presence of R. mucilaginosa implied the failure of sanitary maintenance procedures. This study suggests that water systems should be designed based on the plans for profound system maintenance. It also suggests that SOP and on-the job training are essential to avoid any operator errors. These results must be carefully considered when either constructing new RO systems or performing maintenance and periodical examination of the equipment. Reverse osmosis (RO) water is used for final rinsing in our washer-disinfector. The authors used the Ishikawa Fishbone diagram to clarify the critical points for optimizing RO water quality. There existed no measures to prevent contamination in the heat-labile RO water system. The storage tank was significantly contaminated and had to be replaced with a new one equipped with a sampling port and water drainage system. Additional filters and an UV treatment lamp were installed. The whole system disinfection started 1.5 years later using a peracetic acid-based compound after confirming the material compatibility. Operator errors occurred when a new water engineer took over the duty from his predecessor. There were neither standard operating procedures (SOPs) nor on-the-job training. The new water engineer had failed to disinfect the sampling port and water drainage system. Rothia mucilaginosa was cultured from the RO water. It is a resident in the oral cavity and upper respiratory tract. This implied the possible failure of sanitary procedures in the system maintenance. The Ishikawa Fishbone diagram was useful for this study. It suggests that water systems should be designed with plans for system maintenance taken into account. It also suggests that SOP and on-the job training are essential in order to avoid operator errors.

  17. Control of dangerous substances in discharges and microbiological abatement: European framework and a case study of an ozone disinfection system.

    PubMed

    Ostoich, M; Serena, F; Falletti, L; Fantoni, A

    2013-01-01

    Directive 2000/60/EC requires the achievement of a 'good chemical status' for surface water within pre-established dates. Disinfection is needed to achieve compulsory final microbial limit values (in Italy for wastewater discharges the parameter Escherichia coli - EC - is imposed by law with a maximum limit value of 5,000 cfu/100 mL). Liquid waste and disinfection by-products must be considered when designing appropriate monitoring of dangerous substances; the specific classes of substances must be investigated according to the typology of received wastewaters and liquid wastes (where applicable) and specific analytical techniques, with Limit of Detection (LOD) lower than the limit values, must be applied; the difficulties faced by national and regional environmental control Agencies is that these techniques have to be applied during ordinary activity and not only for research purposes. The study aims to present the control of dangerous substances, as a screening view, in wastewater treatment plant (WWTP) discharges in the province of Venice (Northern Italy) for the period 2007-2010 based on available data from institutional controls. In addition, the wastewater disinfection process with ozone applied to a medium size WWTP (45,000 Population Equivalents) is presented as a case study, with a view to assessing the microbiological abatement efficacy and the presence of dangerous substances. Discharge quality of the WWTPs in the province of Venice presented mean values that were higher than the LOD, but only for certain metals. For the Paese plant, zinc and chloroform were the only micro-pollutants detected with a higher level than the LOD. From microbiological data in the period 2006-2011 the disinfection abatement efficiency for Paese was, in most cases above 99% for EC, faecal coliform (FC), faecal streptococci (FS) while efficiency was slightly lower for total coliform (TC); however, the proposed criterion aimed at respecting 99.99% abatement was not completely satisfied. Therefore, despite the high organic and industrial load of the considered plant and the need to find an alternative system for chlorine, as chlorine disinfection has been banned in the Veneto region since December 2012, ozone efficiency is not completely satisfactory and other systems such as peracetic or performic acids and UV systems must be considered.

  18. Perturbation of cytochrome P450, generation of oxidative stress and induction of DNA damage in Cyprinus carpio exposed in situ to potable surface water.

    PubMed

    Sapone, Andrea; Gustavino, Bianca; Monfrinotti, Monica; Canistro, Donatella; Broccoli, Massimiliano; Pozzetti, Laura; Affatato, Alessandra; Valgimigli, Luca; Forti, Giorgio Cantelli; Pedulli, Gian Franco; Biagi, Gian Luigi; Abdel-Rahman, Sherif Z; Paolini, Moreno

    2007-01-10

    Epidemiological evidence suggests a link between consumption of chlorinated drinking water and various cancers. Chlorination of water rich in organic chemicals produces carcinogenic organochlorine by-products (OBPs) such as trihalomethanes and haloacetic acids. Since the discovery of the first OBP in the 1970s, there have been several investigations designed to determine the biological effects of single chemicals or small artificial OBP combinations. However, there is still insufficient information regarding the general biological response to these compounds, and further studies are still needed to evaluate their potential genotoxic effects. In the current study, we evaluated the effect of three drinking water disinfectants on the activity of cytochrome P450 (CYP)-linked metabolizing enzymes and on the generation of oxidative stress in the livers of male and female Cyprinus carpio fish (carp). The fish were exposed in situ for up 20 days to surface water obtained from the Trasmene lake in Italy. The water was treated with 1-2 mg/L of either sodium hypochlorite (NaClO) or chlorine dioxide (ClO2) as traditional disinfectants or with a relatively new disinfectant product, peracetic acid (PAA). Micronucleus (MN) frequencies in circulating erythrocytes from the fish were also analysed as a biomarker of genotoxic effect. In the CYP-linked enzyme assays, a significant induction (up to a 57-fold increase in the deethylation of ethoxyresorufin with PAA treatment) and a notable inactivation (up to almost a 90% loss in hydroxylation of p-nitrophenol with all disinfectants, and of testosterone 2beta-hydroxylation with NaClO) was observed in subcellular liver preparations from exposed fish. Using the electron paramagnetic resonance (EPR) spectroscopy radical-probe technique, we also observed that CYP-modulation was associated with the production of reactive oxygen species (ROS). In addition, we found a significant increase in MN frequency in circulating erythrocytes after 10 days of exposure of fish to water treated with ClO2, while a non-significant six-fold increase in MN frequency was observed with NaClO, but not with PAA. Our data suggest that the use of ClO2 and NaClO to disinfect drinking water could generate harmful OBP mixtures that are able to perturb CYP-mediated reactions, generate oxidative stress and induce genetic damage. These data may provide a mechanistic explanation for epidemiological studies linking consumption of chlorinated drinking water to increased risk of urinary, gastrointestinal and bladder cancers.

  19. Supercritical carbon dioxide-based sterilization of decellularized heart valves

    PubMed Central

    Hennessy, Ryan S.; Jana, Soumen; Tefft, Brandon J.; Helder, Meghana R.; Young, Melissa D.; Hennessy, Rebecca R.; Stoyles, Nicholas J.; Lerman, Amir

    2017-01-01

    Objective The goal of this research project encompasses finding the most efficient and effective method of decellularized tissue sterilization. Background Aortic tissue grafts have been utilized to repair damaged or diseased valves. Although, the tissues for grafting are collected aseptically, it does not eradicate the risk of contamination nor disease transfer. Thus, sterilization of grafts is mandatory. Several techniques have been applied to sterilize grafts; however, each technique shows drawbacks. In this study, we compared several sterilization techniques: supercritical carbon dioxide, electrolyzed water, gamma radiation, ethanol-peracetic acid, and hydrogen peroxide for impact on the sterility and mechanical integrity of porcine decellularized aortic valves. Methods Valve sterility was characterized by histology, microbe culture, and electron microscopy. Uniaxial tensile testing was conducted on the valve cusps along their circumferential orientation to study these sterilization techniques on their integrity. Results Ethanol-peracetic acid and supercritical carbon dioxide treated valves were found to be sterile. The tensile strength of supercritical carbon dioxide treated valves (4.28 ± 0.22 MPa) was higher to those valves treated with electrolyzed water, gamma radiation, ethanol-peracetic acid and hydrogen peroxide (1.02 ± 0.15, 1.25 ± 0.25, 3.53 ± 0.41 and 0.37 ± 0.04 MPa, respectively). Conclusions Superior sterility and integrity were found in the decellularized porcine aortic valves with supercritical carbon dioxide sterilization. This sterilization technique may hold promise for other decellularized soft tissues. Summary Sterilization of grafts is essential. Supercritical carbon dioxide, electrolyzed water, gamma radiation, ethanol-peracetic acid, and hydrogen peroxide techniques were compared for impact on sterility and mechanical integrity of porcine decellularized aortic valves. Ethanol-peracetic acid and supercritical carbon dioxide treated valves were found to be sterile using histology, microbe culture and electron microscopy assays. The cusp tensile properties of supercritical carbon dioxide treated valves were higher compared to valves treated with other techniques. Superior sterility and integrity was found in the decellularized valves treated with supercritical carbon dioxide sterilization. This sterilization technique may hold promise for other decellularized soft tissues. PMID:28337488

  20. Micelle-assisted signaling of peracetic acid by the oxidation of pyreneboronic acid via monomer-excimer switching.

    PubMed

    Choi, Jiyoung; Lee, Hyo Jin; Cho, Min Jeoung; Chang, Suk-Kyu

    2015-08-15

    A simple fluorescent probe for the industrial oxidant peracetic acid (PAA) was investigated. PAA-assisted oxidative conversion of pyrene-1-boronic acid into 1-hydroxypyrene was used as the signaling tool. Pyreneboronic acid was found to display selective signaling behavior, being more responsive to PAA than to other commonly used practical oxidants such as H2O2 and HOCl. The changes in pyrene monomer fluorescence to excimer were used in the quantitative analysis of PAA. When using the surfactant hexadecyltrimethylammonium bromide as a micellar additive, the signaling of PAA was markedly enhanced. Selective fluorescence signaling of PAA by pyrene-1-boronic acid with a detection limit of 1.5×10(-6)M in aqueous environment was successfully achieved. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Can vaccinia virus be replaced by MVA virus for testing virucidal activity of chemical disinfectants?

    PubMed

    Rabenau, Holger F; Rapp, Ingrid; Steinmann, Jochen

    2010-06-23

    Vaccinia virus strain Lister Elstree (VACV) is a test virus in the DVV/RKI guidelines as representative of the stable enveloped viruses. Since the potential risk of laboratory-acquired infections with VACV persists and since the adverse effects of vaccination with VACV are described, the replacement of VACV by the modified vaccinia Ankara strain (MVA) was studied by testing the activity of different chemical biocides in three German laboratories. The inactivating properties of different chemical biocides (peracetic acid, aldehydes and alcohols) were tested in a quantitative suspension test according to the DVV/RKI guideline. All tests were performed with a protein load of 10% fetal calf serum with both viruses in parallel using different concentrations and contact times. Residual virus was determined by endpoint dilution method. The chemical biocides exhibited similar virucidal activity against VACV and MVA. In three cases intra-laboratory differences were determined between VACV and MVA - 40% (v/v) ethanol and 30% (v/v) isopropanol are more active against MVA, whereas MVA seems more stable than VACV when testing with 0.05% glutardialdehyde. Test accuracy across the three participating laboratories was high. Remarkably inter-laboratory differences in the reduction factor were only observed in two cases. Our data provide valuable information for the replacement of VACV by MVA for testing chemical biocides and disinfectants. Because MVA does not replicate in humans this would eliminate the potential risk of inadvertent inoculation with vaccinia virus and disease in non-vaccinated laboratory workers.

  2. Biocidal and Sporicidal Efficacy of Pathoster® 0.35% and Pathoster® 0.50% Against Bacterial Agents in Potential Bioterrorism Use

    PubMed Central

    Candeliere, Antonio; Donatiello, Adelia; Pagano, Stefania; Iatarola, Michela; Tolve, Francesco; Antonino, Leonardo; Fasanella, Antonio

    2016-01-01

    The use of products that can neutralize or significantly reduce the microbial load and that are not harmful to human health and the environment represents a milestone in the fight against the spread of infectious diseases. Peracetic acid, besides being an excellent sterilizing and sporicidal agent, is harmless to humans and the environment when it is used in a common dosage. However, the high costs and loss of efficacy of the product very quickly after its reconstitution limit its use. We evaluated the efficacy and stability of 2 commercial products, based on stabilized peracetic acid (Pathoster® 0.35% and Pathoster® 0.50%) used against spores of Bacillus anthracis and spores of Bacillus cereus and vegetative forms of Yersinia pestis, Burkholderia mallei, Burkholderia pseudomallei, Francisella tularensis, Brucella abortus, and Brucella melitensis. The efficacy tests were based on the direct contact of the products with a standard suspension of the bacteria. The stability of the products was defined as the period of time during which the biocidal and sporicidal properties remained unchanged. The limit of effectiveness was the period after which the product was unable to exert a complete sterilization after a contact of 5 minutes with at least 1 of the 8 bacteria used in this work. Both formulations showed good efficacy against the microorganisms used in the study, confirming the utility of peracetic acid as a sterilizing product. After the reconstitution, Pathoster® 0.35% was stable until 16±1 days, while Pathoster® 0.50% was stable until 24±1 days. The formulations used in this study showed good performance and a significant stability of peracetic acid. PMID:27482880

  3. Biocidal and Sporicidal Efficacy of Pathoster(®) 0.35% and Pathoster(®) 0.50% Against Bacterial Agents in Potential Bioterrorism Use.

    PubMed

    Candeliere, Antonio; Campese, Emanuele; Donatiello, Adelia; Pagano, Stefania; Iatarola, Michela; Tolve, Francesco; Antonino, Leonardo; Fasanella, Antonio

    2016-01-01

    The use of products that can neutralize or significantly reduce the microbial load and that are not harmful to human health and the environment represents a milestone in the fight against the spread of infectious diseases. Peracetic acid, besides being an excellent sterilizing and sporicidal agent, is harmless to humans and the environment when it is used in a common dosage. However, the high costs and loss of efficacy of the product very quickly after its reconstitution limit its use. We evaluated the efficacy and stability of 2 commercial products, based on stabilized peracetic acid (Pathoster(®) 0.35% and Pathoster(®) 0.50%) used against spores of Bacillus anthracis and spores of Bacillus cereus and vegetative forms of Yersinia pestis, Burkholderia mallei, Burkholderia pseudomallei, Francisella tularensis, Brucella abortus, and Brucella melitensis. The efficacy tests were based on the direct contact of the products with a standard suspension of the bacteria. The stability of the products was defined as the period of time during which the biocidal and sporicidal properties remained unchanged. The limit of effectiveness was the period after which the product was unable to exert a complete sterilization after a contact of 5 minutes with at least 1 of the 8 bacteria used in this work. Both formulations showed good efficacy against the microorganisms used in the study, confirming the utility of peracetic acid as a sterilizing product. After the reconstitution, Pathoster(®) 0.35% was stable until 16±1 days, while Pathoster(®) 0.50% was stable until 24±1 days. The formulations used in this study showed good performance and a significant stability of peracetic acid.

  4. Respiratory Symptoms in Hospital Cleaning Staff Exposed to a Product Containing Hydrogen Peroxide, Peracetic Acid, and Acetic Acid

    PubMed Central

    Hawley, Brie; Casey, Megan; Virji, Mohammed Abbas; Cummings, Kristin J.; Johnson, Alyson; Cox-Ganser, Jean

    2017-01-01

    Cleaning and disinfecting products consisting of a mixture of hydrogen peroxide (HP), peracetic acid (PAA), and acetic acid (AA) are widely used as sporicidal agents in health care, childcare, agricultural, food service, and food production industries. HP and PAA are strong oxidants and their mixture is a recognized asthmagen. However, few exposure assessment studies to date have measured HP, PAA, and AA in a health care setting. In 2015, we performed a health and exposure assessment at a hospital where a new sporicidal product, consisting of HP, PAA, and AA was introduced 16 months prior. We collected 49 full-shift time-weighted average (TWA) air samples and analyzed samples for HP, AA, and PAA content. Study participants were observed while they performed cleaning duties, and duration and frequency of cleaning product use was recorded. Acute upper airway, eye, and lower airway symptoms were recorded in a post-shift survey (n = 50). A subset of 35 cleaning staff also completed an extended questionnaire that assessed symptoms reported by workers as regularly occurring or as having occurred in the previous 12 months. Air samples for HP (range: 5.5 to 511.4 ppb) and AA (range: 6.7 to 530.3 ppb) were all below established US occupational exposure limits (OEL). To date, no full-shift TWA OEL for PAA has been established in the United States, however an OEL of 0.2 ppm has been suggested by several research groups. Air samples for PAA ranged from 1.1 to 48.0 ppb and were well below the suggested OEL of 0.2 ppm. Hospital cleaning staff using a sporicidal product containing HP, PAA, and AA reported work-shift eye (44%), upper airway (58%), and lower airway (34%) symptoms. Acute nasal and eye irritation were significantly positively associated with increased exposure to the mixture of the two oxidants: HP and PAA, as well as the total mixture (TM) of HP, PAA, and AA. Shortness of breath when hurrying on level ground or walking up a slight hill was significantly associated with increased exposure to the oxidant mixture (P = 0.017), as well as the TM (P = 0.026). Our results suggest that exposure to a product containing HP, PAA, and AA contributed to eye and respiratory symptoms reported by hospital cleaning staff at low levels of measured exposure. PMID:29077798

  5. Material Testing in Support of the ISS Electrochemical Disinfection Feasibility Study

    NASA Technical Reports Server (NTRS)

    Clements, Anna; Shindo, David; Modica, Cathy

    2011-01-01

    The International Space Station Program recognizes the risk of microbial contamination in their potable and non-potable water sources. With the end of the Space Shuttle Program, the ability to send up shock-kits of biocides in the event of an outbreak becomes even more difficult. Currently, the US Segment water system relies primarily on iodine to mitigate contamination concerns. To date, several small cases of contamination have occurred which have been remediated. NASA, however, realizes that having a secondary method of combating a microbial outbreak is a prudent investment. NASA is looking into developing hardware that can generate biocides electrochemically, and potentially deploying that hardware. The specific biocides that the technology could generate include: hydrogen peroxide, oxone, hypochlorite and peracetic acid. In order to use these biocides on deployed water systems, the project must determine that all the materials in the potential application are compatible with the biocides at their anticipated administered concentrations. This paper will detail the materials test portion of the feasibility assessment including the plan for both metals and non-metals along with results to date.

  6. Biofilm formation and biocides sensitivity of Pseudomonas marginalis isolated from a maple sap collection system.

    PubMed

    Lagacé, L; Jacques, M; Mafu, A A; Roy, D

    2006-10-01

    The susceptibility of planktonic and biofilm cells of Pseudomonas marginalis toward four commonly used biocides at different temperatures (15 and 30 degrees C) and biofilm growth times (24 and 48 h) was assessed. Using the MBEC biofilm device, biofilm production in maple sap was shown to be highly reproducible for each set of conditions tested. Biofilm formation was influenced by growth temperature and time. A temperature of 15 degrees C and incubation time of 24 h yielded fewer CFU per peg and showed fewer adhered cells and typical biofilm structures, based on scanning electron microscopy observations as compared with other conditions. Minimal biofilm eradication concentration values for P. marginalis were significantly greater (P. < 0.001) than were MBCs for planktonic cells and for every biocide tested, with the exception of minimal biofilm eradication concentration values for peracetic acid at 15 degrees C and 24 h. Sodium hypochlorite and peracetic acid sanitizers were able to eliminate P. marginalis biofilms at lower concentrations as compared with hydrogen peroxide- and quaternary ammonium-based sanitizers (P < 0.001). According to the results obtained, sodium hypochlorite and peracetic acid sanitizers would be more appropriate for maple sap collection system sanitation.

  7. Determination of decimal reduction time (D value) of chemical agents used in hospitals for disinfection purposes

    PubMed Central

    Mazzola, Priscila Gava; Penna, Thereza Christina Vessoni; da S Martins, Alzira M

    2003-01-01

    Background Prior to the selection of disinfectants for low, intermediate and high (sterilizing) levels, the decimal reduction time, D-value, for the most common and persistent bacteria identified at a health care facility should be determined. Methods The D-value was determined by inoculating 100 mL of disinfecting solution with 1 mL of a bacterial suspension (104 – 105 CFU/mL for vegetative and spore forms). At regular intervals, 1 mL aliquots of this mixture were transferred to 8 mL of growth media containing a neutralizing agent, and incubated at optimal conditions for the microorganism. Results The highest D-values for various bacteria were determined for the following solutions: (i) 0.1% sodium dichloroisocyanurate (pH 7.0) – E. coli and A. calcoaceticus (D = 5.9 min); (ii) sodium hypochlorite (pH 7.0) at 0.025% for B. stearothermophilus (D = 24 min), E. coli and E. cloacae (D = 7.5 min); at 0.05% for B. stearothermophilus (D = 9.4 min) and E. coli (D = 6.1 min) and 0.1% for B. stearothermophilus (D = 3.5 min) and B. subtilis (D = 3.2 min); (iii) 2.0% glutaraldehyde (pH 7.4) – B. stearothermophilus, B. subtilis (D = 25 min) and E. coli (D = 7.1 min); (iv) 0.5% formaldehyde (pH 6.5) – B. subtilis (D = 11.8 min), B. stearothermophilus (D = 10.9 min) and A. calcoaceticus (D = 5.2 min); (v) 2.0% chlorhexidine (pH 6.2) – B. stearothermophilus (D = 9.1 min), and at 0.4% for E. cloacae (D = 8.3 min); (vi) 1.0% Minncare® (peracetic acid and hydrogen peroxide, pH 2.3) – B. stearothermophilus (D = 9.1 min) and E. coli (D = 6.7 min). Conclusions The suspension studies were an indication of the disinfectant efficacy on a surface. The data in this study reflect the formulations used and may vary from product to product. The expected effectiveness from the studied formulations showed that the tested agents can be recommended for surface disinfection as stated in present guidelines and emphasizes the importance and need to develop routine and novel programs to evaluate product utility. PMID:14563217

  8. Isolation, pathogenicity and disinfection of Staphylococcus aureus carried by insects in two public hospitals of Vitória da Conquista, Bahia, Brazil.

    PubMed

    Oliveira, Pollianna S; Souza, Simone G; Campos, Guilherme B; da Silva, Danilo C C; Sousa, Daniel S; Araújo, Suerda P F; Ferreira, Laiziane P; Santos, Verena M; Amorim, Aline T; Santos, Angelita M O G; Timenetsky, Jorge; Cruz, Mariluze P; Yatsuda, Regiane; Marques, Lucas M

    2014-01-01

    Currently, hospital infection is a serious public health problem, and several factors may influence the occurrence of these infections, including the presence of insects, which are carriers of multidrug-resistant bacterial species. The aim of this study was to isolate staphylococci carried by insects in two public hospitals of Vitoria da Conquista, Bahia and to identify the resistance profile, pathogenicity and efficacy of disinfection of the premises. A total of 91 insects were collected in 21 strategic points of these hospitals, and 32 isolated strains of Staphylococcus aureus were isolated. Based on antibiogram and Minimum Inhibitory Concentration results, 95% of these strains were susceptible to oxacillin. These strains were also evaluated for the presence of resistance genes encoding resistance to oxacillin/methicillin by polymerase chain reaction, but the sample was negative for this gene. Pathogenicity tests were performed in vitro biofilm formation induced by glucose, where it was found that eight (27.58%) strains were classified as biofilm producers and 21 (72.4%) as stronger producers. In addition, we performed PCR for their virulence genes: Sea (enterotoxin A), SEB (B), Sec (C), PVL (Panton-Valentine Leukocidin), ClfA (clumping factor A) and Spa (protein A). Of these, Sea, Spa PVL were positive in 7 (21.8%), 2 (6.3%) and 1 (3.1%) samples, respectively. The analysis of cytokine induction in the inflammatory response of J774 macrophages by isolates from the two hospitals did not show statistical difference at the levels of IL-6, TNF-α, IL-1 and IL-10 production. In addition, we verified the antimicrobial activity of disinfecting agents on these strains, quaternary ammonium, 0.5% sodium hypochlorite, 1% sodium hypochlorite, 2% sodium hypochlorite, 2% glutaraldehyde, Lysoform(®), 70% alcohol solution of chlorhexidine digluconate, 2% peracetic acid, and 100% vinegar. Resistance was seen in only for the following two disinfectants: 70% alcohol in 31 (96.8%) samples tested and vinegar in 30 (93.8%) samples. The study demonstrated the presence of resistant and pathogenic organisms conveyed by insects, thus suggesting improvement in efforts to control these vectors. Copyright © 2013 Elsevier Editora Ltda. All rights reserved.

  9. Growth medium sterilization using decomposition of peracetic acid for more cost-efficient production of omega-3 fatty acids by Aurantiochytrium.

    PubMed

    Cho, Chang-Ho; Shin, Won-Sub; Woo, Do-Wook; Kwon, Jong-Hee

    2018-06-01

    Aurantiochytrium can produce significant amounts of omega-3 fatty acids, specifically docosahexaenoic acid and docosapentaenoic acid. Use of a glucose-based medium for heterotrophic growth is needed to achieve a high growth rate and production of abundant lipids. However, heat sterilization for reliable cultivation is not appropriate to heat-sensitive materials and causes a conversion of glucose via browning (Maillard) reactions. Thus, the present study investigated the use of a direct degradation of Peracetic acid (PAA) for omega-3 production by Aurantiochytrium. Polymer-based bioreactor and glucose-containing media were chemically co-sterilized by 0.04% PAA and neutralized through a reaction with ferric ion (III) in HEPES buffer. Mono-cultivation was achieved without the need for washing steps and filtration, thereby avoiding the heat-induced degradation and dehydration of glucose. Use of chemically sterilized and neutralized medium, rather than heat-sterilized medium, led to a twofold faster growth rate and greater productivity of omega-3 fatty acids.

  10. Resistance of two temperate Lactobacillus paracasei bacteriophages to high pressure homogenization, thermal treatments and chemical biocides of industrial application.

    PubMed

    Mercanti, D J; Guglielmotti, D M; Patrignani, F; Reinheimer, J A; Quiberoni, A

    2012-02-01

    Temperate bacteriophages ф iLp84 and ф iLp1308, previously isolated from mitomycin C-induction of Lactobacillus paracasei strains 84 and CNRZ1308, respectively, were tested for their resistance to several physical and chemical treatments applied in dairy industry. Long-term survival at 4 °C, -20 °C and -80 °C, resistance to either thermal treatments of 63 °C, 72 °C and 90 °C, high pressure homogenization (HPH, 100 MPa) or classic (ethanol, sodium hypochlorite and peracetic acid) and new commercial sanitizers, namely A (quaternary ammonium chloride), B (hydrogen peroxide, peracetic acid and peroctanoic acid), C (alkaline chloride foam), D (p-toluensulfonchloroamide, sodium salt) and E (ethoxylated nonylphenol and phosphoric acid), were determined. Phages were almost completely inactivated after eight months of storage at 25 °C, but viability was not affected at 4 °C, -20 °C or -80 °C. Both phages tolerated well HPH treatments. Phage iLp1308 showed higher thermal resistance than ф iLp84, but neither resisted 90 °C for 2 min. Best chemical inactivation was accomplished using peracetic acid or biocides A, C and E, whereas biocides B and D were completely ineffective. These results help to improve selection of chemical agents and physical treatments to effectively fight against phage infections in dairy plants. Copyright © 2011 Elsevier Ltd. All rights reserved.

  11. Histological changes and antioxidant enzyme activity in signal crayfish (Pacifastacus leniusculus) associated with sub-acute peracetic acid exposure.

    PubMed

    Chupani, Latifeh; Zuskova, Eliska; Stara, Alzbeta; Velisek, Josef; Kouba, Antonin

    2016-01-01

    Peracetic acid (PAA) is a powerful disinfectant recently adopted as a therapeutic agent in aquaculture. A concentration of 10 mg L(-1) PAA effectively suppresses zoospores of Aphanomyces astaci, the agent of crayfish plague. To aid in establishing safe therapeutic guideline, the effects of PAA on treated crayfish were investigated through assessment of histological changes and oxidative damage. Adult female signal crayfish Pacifastacus leniusculus (n = 135) were exposed to 2 mg L(-1) and 10 mg L(-1) of PAA for 7 days followed by a 7 day recovery period in clean water. Superoxide dismutase activity was significantly lower in gill and hepatopancreas after three days exposure to 10 mg L(1) PAA than in the group treated with 2 mg L(-1) PAA and a control in only clean water. Catalase activity in gill and hepatopancreas remained unaffected by both exposures. Glutathione reductase was significantly decreased in gill of 10 mg L(-1) PAA treated crayfish and increased in group exposed to 2 mg L(-1) compared to control after 7 days exposure. Antioxidant enzyme activity in exposed groups returned to control values after recovery period. Gill, hepatopancreas, and antennal gland showed slight damage in crayfish treated with 2 mg L(-1) of PAA compared to the control group. The extent and frequency of histological alterations were more pronounced in animals exposed to 10 mg L(-1). The gill was the most affected organ, infiltrated by granular hemocytes and displaying malformations of lamella tips and disorganization of epithelial cells. After a 7 day recovery period, the infiltrating cells in affected tissues of the exposed crayfish began to return to normal levels. Results suggested that the given concentrations could be applied to signal crayfish against crayfish plague agent in aquaculture; however, further studies are required for safe use. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Reduction of an E. coli O157:H7 and Salmonella composite on fresh strawberries by varying antimicrobial washes and vacuum perfusion.

    PubMed

    Gurtler, Joshua B; Bailey, Rebecca B; Jin, Tony Z; Fan, Xuetong

    2014-10-17

    A 2011 outbreak of hemorrhagic colitis, which resulted in the death of two individuals, was associated with contaminated strawberries. A study was conducted to identify antimicrobial washes effective at reducing E. coli O157:H7 and Salmonella enterica from the surface of fresh whole strawberries during two-minute immersion washes. Twenty-seven antimicrobial treatments were tested. Vacuum perfusion was applied to strawberries during chlorine and peracetic acid treatments to promote infiltration of sanitizer into porous strawberry tissue. Strawberries were inoculated to 7.1logCFU/strawberry with a seven-strain bacterial composite, consisting of three strains of E. coli O157:H7 and four serovars of Salmonella enterica. Berries were air-dried for 2h and immersed in circulating antimicrobial solutions for 120s at 22°C. Four treatments reduced ≥3.0logCFU/strawberry, including (a) 1% acetic acid+1% H2O2, (b) 30% ethanol+1% H2O2, (c) 90ppm peracetic acid, and (d) 1% lactic acid+1% H2O2. Two additional treatments that reduced 2.8logCFU/strawberry were (a) 40% ethanol, and (b) 1% each of phosphoric+fumaric acids. Eight treatments reduced 2.0-2.6logCFU/strawberry. Five treatments reduced <1.45CFU/strawberry, including (a) 1% citric acid, (b) 1% lactic acid, (c) 1% acetic acid, (d) 0.5% each of acetic+citric acids and (e) 0.5% each of acetic+lactic acids. The use of vacuum perfusion with 200ppm chlorine or 90ppm peracetic acid did not reduce greater populations of pathogens than did the same treatments without vacuum perfusion. Fourteen treatments reduced no more pathogens (p<0.05) than did sterile deionized water. Results from this study provide some options for end-point decontamination of strawberries for retail operations just prior to serving to customers. Published by Elsevier B.V.

  13. Mammalian Cell Cytotoxicity and Genotoxicity of the Haloacetic Acids, A Major Class of Drinking Water Disinfection By-Products

    EPA Science Inventory

    The haloacetic acids (HAAs) are disinfection by-products (DBPs) that are formed during the disinfection of drinking water, wastewaters and recreational pool waters. Currently, five HAAs [bromoacetic acid (BAA), dibromoacetic acid (DBAA), chloroacetic acid (CAA), dichloroacetic ac...

  14. Respiratory Symptoms in Hospital Cleaning Staff Exposed to a Product Containing Hydrogen Peroxide, Peracetic Acid, and Acetic Acid.

    PubMed

    Hawley, Brie; Casey, Megan; Virji, Mohammed Abbas; Cummings, Kristin J; Johnson, Alyson; Cox-Ganser, Jean

    2017-12-15

    Cleaning and disinfecting products consisting of a mixture of hydrogen peroxide (HP), peracetic acid (PAA), and acetic acid (AA) are widely used as sporicidal agents in health care, childcare, agricultural, food service, and food production industries. HP and PAA are strong oxidants and their mixture is a recognized asthmagen. However, few exposure assessment studies to date have measured HP, PAA, and AA in a health care setting. In 2015, we performed a health and exposure assessment at a hospital where a new sporicidal product, consisting of HP, PAA, and AA was introduced 16 months prior. We collected 49 full-shift time-weighted average (TWA) air samples and analyzed samples for HP, AA, and PAA content. Study participants were observed while they performed cleaning duties, and duration and frequency of cleaning product use was recorded. Acute upper airway, eye, and lower airway symptoms were recorded in a post-shift survey (n = 50). A subset of 35 cleaning staff also completed an extended questionnaire that assessed symptoms reported by workers as regularly occurring or as having occurred in the previous 12 months. Air samples for HP (range: 5.5 to 511.4 ppb) and AA (range: 6.7 to 530.3 ppb) were all below established US occupational exposure limits (OEL). To date, no full-shift TWA OEL for PAA has been established in the United States, however an OEL of 0.2 ppm has been suggested by several research groups. Air samples for PAA ranged from 1.1 to 48.0 ppb and were well below the suggested OEL of 0.2 ppm. Hospital cleaning staff using a sporicidal product containing HP, PAA, and AA reported work-shift eye (44%), upper airway (58%), and lower airway (34%) symptoms. Acute nasal and eye irritation were significantly positively associated with increased exposure to the mixture of the two oxidants: HP and PAA, as well as the total mixture (TM)of HP, PAA, and AA. Shortness of breath when hurrying on level ground or walking up a slight hill was significantly associated with increased exposure to the oxidant mixture (P = 0.017), as well as the TM (P = 0.026). Our results suggest that exposure to a product containing HP, PAA, and AA contributed to eye and respiratory symptoms reported by hospital cleaning staff at low levels of measured exposure. Published by Oxford University Press on behalf of the British Occupational Hygiene Society 2017.

  15. OCCURRENCE AND TOXICITY OF IODO-ACID DISINFECTION BY-PRODUCTS IN CHLORAMINATED DRINKING WATER

    EPA Science Inventory

    As part of a recent Nationwide Disinfection By-Product (DBP) Occurrence Study, iodo-acids were identified for the first time as DBPs in drinking water disinfected with chloramines. The iodo-acids identified included iodoacetic acid (IAA), bromoiodoacetic acid, (E)-3-bromo-3-iodo...

  16. OCCURRENCE OF IODO-ACID AND IODO-THM DISINFECTION BY-PRODUCTS IN CHLORAMINATED DRINKING WATER

    EPA Science Inventory

    As part of a recent Nationwide Disinfection By-Product (DBP) Occurrence Study, iodo-acids were identified for the first time as DBPs in drinking water disinfected with chloramines. The iodo-acids identified included iodoacetic acid, bromoiodoacetic acid, (E)-3-bromo-3-iodo-prope...

  17. OCCURRENCE OF IODO-ACID AND IODO-THM DISINFECTION BY-PRODUCTS IN DRINKING WATER

    EPA Science Inventory

    As part of a recent Nationwide Disinfection By-product (DBP) Occurrence Study, iodo-acids were identified for the first time as DBPs in drinking water disinfected with chloramines. The iodo-acids identified included iodoacetic acid, bromoiodoacetic acid, (E)-3-bromo-3-iodo- prope...

  18. Evaluation of peracetic acid fog for the inactivation of Bacillus anthracis spore surrogates in a large decontamination chamber.

    PubMed

    Wood, Joseph P; Calfee, Michael Worth; Clayton, Matthew; Griffin-Gatchalian, Nicole; Touati, Abderrahmane; Egler, Kim

    2013-04-15

    The purpose of this study was to evaluate the sporicidal (inactivation of bacterial spores) effectiveness and operation of a fogging device utilizing peracetic acid/hydrogen peroxide (PAA). Experiments were conducted in a pilot-scale 24 m(3) stainless steel chamber using either biological indicators (BIs) or bacterial spores deposited onto surfaces via aerosolization. Wipe sampling was used to recover aerosol-deposited spores from chamber surfaces and coupon materials before and after fogging to assess decontamination efficacy. Temperature, relative humidity, and hydrogen peroxide vapor levels were measured during testing to characterize the fog environment. The fog completely inactivated all BIs in a test using a 60 mL solution of PAA (22% hydrogen peroxide/4.5% peracetic acid). In tests using aerosol-deposited bacterial spores, the majority of the post-fogging spore levels per sample were less than 1 log colony forming units, with a number of samples having no detectable spores. In terms of decontamination efficacy, a 4.78 log reduction of viable spores was achieved on wood and stainless steel. Fogging of PAA solutions shows potential as a relatively easy to use decontamination technology in the event of contamination with Bacillus anthracis or other spore-forming infectious disease agents, although additional research is needed to enhance sporicidal efficacy. Published by Elsevier B.V.

  19. IODO-ACID DISINFECTION BY-PRODUCTS IN DRINKING WATER: DOES LC/ESI-MS/MS OFFER AN ADVANTAGE OVER GC/NCI-MS?

    EPA Science Inventory

    As part of a recent Nationwide Disinfection By-Product (DBP) Occurrence Study, iodo-acids were identified for the first time as DBPs in drinking water disinfected with chloramines. The iodo-acids identified included iodoacetic acid, bromoiodoacetic acid, (E)-3-bromo-3-iodo-prope...

  20. Peracetic Acid Depolymerization of Biorefinery Lignin for Production of Selective Monomeric Phenolic Compounds.

    PubMed

    Ma, Ruoshui; Guo, Mond; Lin, Kuan-Ting; Hebert, Vincent R; Zhang, Jinwen; Wolcott, Michael P; Quintero, Melissa; Ramasamy, Karthikeyan K; Chen, Xiaowen; Zhang, Xiao

    2016-07-25

    Lignin is the largest source of renewable material with an aromatic skeleton. However, due to the recalcitrant and heterogeneous nature of the lignin polymer, it has been a challenge to effectively depolymerize lignin and produce high-value chemicals with high selectivity. In this study, a highly efficient lignin-to-monomeric phenolic compounds (MPC) conversion method based on peracetic acid (PAA) treatment was reported. PAA treatment of two biorefinery lignin samples, diluted acid pretreated corn stover lignin (DACSL) and steam exploded spruce lignin (SESPL), led to complete solubilization and production of selective hydroxylated monomeric phenolic compounds (MPC-H) and monomeric phenolic acid compounds (MPC-A) including 4-hydroxy-2-methoxyphenol, p-hydroxybenzoic acid, vanillic acid, syringic acid, and 3,4-dihydroxybenzoic acid. The maximized MPC yields obtained were 18 and 22 % based on the initial weight of the lignin in SESPL and DACSL, respectively. However, we found that the addition of niobium pentoxide catalyst to PAA treatment of lignin can significantly improve the MPC yields up to 47 %. The key reaction steps and main mechanisms involved in this new lignin-to-MPC valorization pathway were investigated and elucidated. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Peracetic Acid Depolymerization of Biorefinery Lignin for Production of Selective Monomeric Phenolic Compounds

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ma, Ruoshui; Guo, Mond; Lin, Kuan-ting

    Lignin is the largest source of renewable material with an aromatic skeleton. However, due to the recalcitrant and heterogeneous nature of the lignin polymer, it has been a challenge to effectively depolymerize lignin and produce high-value chemicals with high selectivity. In this study, a highly efficient lignin-to-monomeric phenolic compounds (MPC) conversion method based on peracetic acid (PAA) treatment was reported. PAA treatment of two biorefinery lignin samples, diluted acid pretreated corn stover lignin (DACSL) and steam exploded spruce lignin (SESPL), led to complete solubilization and production of selective hydroxylated monomeric phenolic compounds (MPC-H) and monomeric phenolic acid compounds (MPC-A) includingmore » 4-hydroxy-2-methoxyphenol, p-hydroxybenzoic acid, vanillic acid, syringic acid, and 3,4-dihydroxybenzoic acid. The maximized MPC yields obtained were 18 and 22 % based on the initial weight of the lignin in SESPL and DACSL, respectively. However, we found that the addition of niobium pentoxide catalyst to PAA treatment of lignin can significantly improve the MPC yields up to 47 %. The key reaction steps and main mechanisms involved in this new lignin-to-MPC valorization pathway were investigated and elucidated.« less

  2. OCCURRENCE AND TOXICITY OF IODINATED DISINFECTION BY-PRODUCTS IN DRINKING WATER

    EPA Science Inventory

    As part of a recent Nationwide Disinfection By-Product (DBP) Occurrence Study, iodo-acids were identified for the first time as DBPs in drinking water disinfected with chloramines. The iodo-acids identified included iodoacetic acid, bromoiodoacetic acid, (E)-3-bromo-3-iodo-prope...

  3. Inactivation of murine norovirus by chemical biocides on stainless steel

    PubMed Central

    2009-01-01

    Background Human norovirus (NoV) causes more than 80% of nonbacterial gastroenteritis in Europe and the United States. NoV transmission via contaminated surfaces may be significant for the spread of viruses. Therefore, measures for prevention and control, such as surface disinfection, are necessary to interrupt the dissemination of human NoV. Murine norovirus (MNV) as a surrogate for human NoV was used to study the efficacy of active ingredients of chemical disinfectants for virus inactivation on inanimate surfaces. Methods The inactivating properties of different chemical biocides were tested in a quantitative carrier test with stainless steel discs without mechanical action. Vacuum-dried MNV was exposed to different concentrations of alcohols, peracetic acid (PAA) or glutaraldehyde (GDA) for 5 minutes exposure time. Detection of residual virus was determined by endpoint-titration on RAW 264.7 cells. Results PAA [1000 ppm], GDA [2500 ppm], ethanol [50% (v/v)] and 1-propanol [30% (v/v)] were able to inactivate MNV under clean conditions (0.03% BSA) on the carriers by ≥ 4 log10 within 5 minutes exposure time, whereas 2-propanol showed a reduced effectiveness even at 60% (v/v). Furthermore, there were no significant differences in virus reduction whatever interfering substances were used. When testing with ethanol, 1- and 2-propanol, results under clean conditions were nearly the same as in the presence of dirty conditions (0.3% BSA plus 0.3% erythrocytes). Conclusion Products based upon PAA, GDA, ethanol and 1-propanol should be used for NoV inactivation on inanimate surfaces. Our data provide valuable information for the development of strategies to control NoV transmission via surfaces. PMID:19583832

  4. Temperate and virulent Lactobacillus delbrueckii bacteriophages: comparison of their thermal and chemical resistance.

    PubMed

    Ebrecht, Ana C; Guglielmotti, Daniela M; Tremmel, Gustavo; Reinheimer, Jorge A; Suárez, Viviana B

    2010-06-01

    The aim of this work was to study the efficiency of diverse chemical and thermal treatments usually used in dairy industries to control the number of virulent and temperate Lactobacillus delbrueckii bacteriophages. Two temperate (Cb1/204 and Cb1/342) and three virulent (BYM, YAB and Ib3) phages were studied. The thermal treatments applied were: 63 degrees C for 30 min (low temperature--long time, LTLT), 72 degrees C for 15 s (high temperature--short time, HTST), 82 degrees C for 5 min (milk destined to yogurt elaboration) and 90 degrees C for 15 min (FIL-IDF). The chemical agents studied were: sodium hypochlorite, ethanol, isopropanol, peracetic acid, biocides A (quaternary ammonium chloride), B (hydrogen peroxide, peracetic acid and peroctanoic acid), C (alkaline chloride foam), D (p-toluensulfonchloroamide, sodium salt) and E (ethoxylated nonylphenol and phosphoric acid). The kinetics of inactivation were drew and T(99) (time necessary to eliminate the 99% of phage particles) calculated. Results obtained showed that temperate phages revealed lower resistance than the virulent ones to the treatment temperatures. Biocides A, C, E and peracetic acid showed a notable efficiency to inactivate high concentrations of temperate and virulent L. delbrueckii phages. Biocide B evidenced, in general, a good capacity to eliminate the phage particles. Particularly for this biocide virulent phage Ib3 showed the highest resistance in comparison to the rest of temperate and virulent ones. On the contrary, biocide D and isopropanol presented a very low capacity to inactivate all phages studied. The efficiency of ethanol and hypochlorite was variable depending to the phages considered. These results allow a better knowledge and give useful information to outline more effective treatments to reduce the phage infections in dairy plants. 2009 Elsevier Ltd. All rights reserved.

  5. 21 CFR 177.2500 - Polyphenylene sulfone resins.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... consist of basic resin produced by reacting polyphenylene sulfide with peracetic acid such that the... sanction or approval. (c) Specifications. The glass transition temperature of the polymer is 360±5 °C as...

  6. 21 CFR 177.2500 - Polyphenylene sulfone resins.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... consist of basic resin produced by reacting polyphenylene sulfide with peracetic acid such that the... sanction or approval. (c) Specifications. The glass transition temperature of the polymer is 360±5 °C as...

  7. Influence of Concentration and Agitation of Sodium Hypochlorite and Peracetic Acid Solutions on Tissue Dissolution.

    PubMed

    Tanomaru-Filho, Mário; Silveira, Bruna Ramos Franco; Martelo, Roberta Bosso; Guerreiro-Tanomaru, Juliane Maria

    2015-11-01

    To evaluated the tissue dissolution of sodium hypochlorite (NaOCl) and peracetic acid (PA) solutions at different concentrations, with or without ultrasonic agitation. The following solutions were analyzed: 2.5% NaOCl, 0.5, 1 and 2% PA, 1% PA associated with 6.5% hydrogen peroxide (HP) and saline. Fragments of bovine pulp tissue with 25 ± 2g mg were immersed into test tubes containing 4 mL of the solutions for 10 minutes. In the groups with agitation, pulp tissues were submitted to 2 cycles of 1 minute of ultrasonic agitation. The specimens were weighed after the removal from the solutions. The percentage of mass loss was calculated according to the difference of mass before and after exposure to solutions. Data were submitted to ANOVA and Tukey tests (p < 0.05). A total of 2.5% NaOCl with or without agitation showed the higher tissue dissolution (between 64.5 and 67% of mass reduction) (p < 0.005). By comparing the PA solutions, the concentrations of 1 and 2% with or without agitation and the concentration of 0.5% with agitation showed similar dissolution activity (between 35.4 and 44% of mass reduction). The use of the ultrasonic agitation promoted an increase of the dissolution ability only for 0.5% PA. Peracetic acid solution has pulp tissue dissolution. However, this ability is lower than 2.5% NaOCl solution. The sodium hypochlorite solution shows higher ability to dissolve tissue than PA.

  8. Comparison of liquid chemical sterilization with peracetic acid and ethylene oxide sterilization for long narrow lumens.

    PubMed

    Alfa, M J; DeGagne, P; Olson, N; Hizon, R

    1998-10-01

    The aim of this study was to determine how well peracetic acid liquid chemical sterilization (LCPAS) killed test organisms in the presence of 10% fetal bovine serum and 0.65% salt challenge (RPMI-S) compared with a 100% ethylene oxide (ETO) sterilizer and an ETO hydrochlorofluorocarbon (ETO-HCFC) sterilization method with long (125 cm), narrow (3-mm internal diameter) flexible lumens as the test carrier. The inoculated lumens were dried overnight before processing. The test organisms included Mycobacterium chelonei, Enterococcus faecalis, and Bacillus subtilis. For all 3 organisms tested, the LCPAS process resulted in a 6 log10 reduction in bacterial load compared with a 2.5 log10 to 6 log10 reduction for the 100% ETO and ETO-HCFC sterilizers. Sterilization was achieved for 100%, 61%, and 67% of the lumen test carriers for the LCPAS, 100% ETO, and ETO-HCFC sterilizers, respectively. The data indicate that of the sterilization methods evaluated, LCPAS was the most effective for sterilizing narrow flexible lumens in the presence of residual inorganic and organic soil. This effectiveness was achieved through a combination of organism wash-off and peracetic acid sterilant killing of organisms. Salt was the major compounding factor for effective ETO gas sterilization, because carriers inoculated with organisms in 10% fetal bovine serum alone all were sterilized by both 100% ETO and ETO-HCFC sterilization methods. Our data support the critical need to ensure adequate precleaning of narrow flexible lumen endoscopes before any sterilization method.

  9. Evaluation of peracetic acid permeation during flash sterilization through pharmaceutical plastic polymers used in cytotoxic reconstitution units.

    PubMed

    Havard, Laurent; Fellous-Jerome, Joelle; Bonan, Brigitte; Pradeau, Dominique; Prognon, Patrice

    2005-01-01

    Peracetic acid (PAA) permeation in flash sterilization was studied using three different plastic infusion bags made of polypropylene and polyethylene, filled with glucose 5% or NaCl 0.9%. The pH was measured and acetic acid (AA) and PAA concentrations were made by reverse phase high-performance liquid chromatography (RP-HPLC). PAA was derivatized by oxidation of methyl tolyl sulfide (MTS) into methyl tolyl sulfoxide (MTSO) detected by ultraviolet (UV) absorbance at 230 nm. The technique has a sensitivity of 0.3 microg x L(-1) and was highly specific. Results showed that pH measurements remain constant and demonstrated the absence of PAA permeation, which was confirmed by the absence of AA permeation regardless of the brand tested, with both unwrapped and overwrapped infusion bags, when flash sterilization is applied. These results allow flash sterilization to be performed with unwrapped infusion bags without any risk of drug degradation by PAA. This makes compounding safer and easier, which improves productivity.

  10. Evaluation of correlation between glucan conversion and degree of delignification depending on pretreatment strategies using Jabon Merah.

    PubMed

    Jang, Soo-Kyeong; Jeong, Hanseob; Kim, Ho-Yong; Choi, June-Ho; Kim, Jong-Hwa; Koo, Bon-Wook; Choi, In-Gyu

    2017-07-01

    The main purpose of this study was to investigate the glucan conversion rate after enzymatic hydrolysis depending on the treatment methods and conditions with changes in the chemical composition of treated solid fraction of Jabon Merah. The glucan conversion rate (17.4%) was not significantly improved after liquid hot water treatment (1st step) even though most of the hemicellulose was dissolved into liquid hydrolysate. Subsequently, dilute acid, organosolv, and peracetic acid treatment (2nd step) was conducted under various conditions to enhance glucan conversion. Among the 2nd step treatment, the glucan conversion rate of organosolv (max. 46.0%) and peracetic acid treatment (max. 65.9%) was increased remarkably through decomposition of acid-insoluble lignin (AIL). Finally, the glucan conversion rate and AIL content were highly correlated, which was revealed by the R-squared value (0.84), but inhibitory factors including cellulose crystallinity must be considered for advanced glucan conversion from highly recalcitrant biomasses, such as Jabon Merah. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. 21 CFR 177.2500 - Polyphenylene sulfone resins.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... polyphenylene sulfide with peracetic acid such that the finished resins meet the specifications set forth in... glass transition temperature of the polymer is 360±5 °C as determined by the use of differential...

  12. Effectiveness of disinfection therapies and promotion of osteoblast growth on osseotite and nanotite implant surfaces.

    PubMed

    Lubin, Judith; Hernandez, Maria A; Drukteinis, Saulius E; Parker, William B; Murray, Peter E

    2014-08-01

    To evaluate the effectiveness of 4 procedures to disinfect implant surfaces intentionally inoculated with bacteria and afterward to evaluate osteoblast viability to the disinfected implant surfaces. Eighty-eight commercially pure Osseotite and Nanotite titanium implant discs were inoculated with Porphyromonas gingivalis. The implant surfaces were disinfected with EDTA, tetracycline, citric acid, or neodymium-doped yttrium aluminum garnet (Nd:YAG) laser. The implant discs were then placed in cultures of osteoblast cells. Osseotite implant discs were easier to disinfect compared with the Nanotite implant discs. Citric acid and tetracycline were the most effective solutions for the disinfection of P. gingivalis from the Osseotite implant discs. The Nanotite implant discs were the most difficult to disinfect, likely because of their chemical and physical properties. Citric acid and tetracycline were most effective for disinfecting the Osseotite implant discs, and further clinical research is needed to verify these effects in vivo. The Nd:YAG laser was the weakest disinfection method, and it is not recommended for disinfecting implant surfaces until its effectiveness is improved.

  13. [Application of peracetic acid for the treatment of juvenile sander (Sander lucioperca) during Ichthyophthirius multifiliis infestation].

    PubMed

    Meinelt, T; Richert, I; Stüber, A; Bräunig, I

    2007-07-01

    White spot disease caused by the ciliate protozoan parasite Ichthyophthirius multifiliis (I. m.), is one of the most dangerous diseases in aquaculture and ornamental fish breeding worldwide. The parasite is characterized by three developmental stages: a reproductive tomont, an infective theront and a parasitic trophont. In sander (Sander lucioperca) breeding I. m. causes serious economic losses. After banning of the traditional therapeutic agent malachite green we have to face a state of emergency for the treatment of the ichthyophthiriasis in Germany. The peracetic acid (PAA), characterized by positive therapeutical properties, might close this gap. The purpose of our investigations was the determination of the toxicity of PES to juvenile sander as well as the evaluation of the therapeutic effectiveness of the substance to combat I. m. For juvenile sander (length 3 cm) we determined a 24-h-LC50 of 1.14 (0.97; 1.3) ppm PES. In two investigations PAA was applied in daily intervals of 0.5; 1, 3, 5 and 24 h and concentrations of 0.5; 1; 1.5 and 2 ppm to treat I.-m.-infection in sander. In test I all sander (length 9 cm) died as a result of the I.-m.-infection. However, the PAA exposed fish survived longer than the PES-free controls! This might be due to a disinfection of other pathogens by PAA. In test II, the fish (length 12 cm) were less infected than fish in test I. Four of six fish died in the group exposed with 2 ppm PAA for 24 hours. The abundance of I.-m.-trophonts was determined in mucus, fin and gill tissues of all fish. Significant differences could not be observed between test I and test II because of dissimilar: 1. exposure in time and concentration, 2. age and condition of the fish and 3. homogenity of the variances. Therefore, no therapy strategy was successful while fighting the parasitic trophonts protected by the overlaying fish tissues. We speculate that a successful therapy of I. m. with PAA is, as known e.g. for malachite green, only possible while fighting the free living stages theronts and tomonts. This will be part of our subsequent investigations.

  14. Evaluation of smear layer removal and marginal adaptation of root canal sealer after final irrigation using ethylenediaminetetraacetic, peracetic, and etidronic acids with different concentrations.

    PubMed

    Ulusoy, Özgür İlke; Zeyrek, Salev; Çelik, Bülent

    2017-07-01

    The purpose of this study was to investigate the effects of different irrigation solutions on the smear layer removal and marginal adaptation of a resin-based sealer to root canal dentine. A total of 152 instrumented roots were irrigated with the following irrigants: 9,18% etidronic acid (HEBP), 0.5, 1,2% peracetic acid (PAA), 17% ethylenediaminetetraacetic acid (EDTA), saline. The amount of smear layer was evaluated using scanning electron microscope (SEM) in seventy root samples. Eighty-two roots were filled with AH Plus and gutta-percha. Slices obtained from apical third of each specimen were viewed with SEM to assess marginal adaptation. Use of 9% and 18% HEBP resulted in more efficient smear layer removal in the apical third than the other chelators (p < 0.05). Higher smear layer scores in the coronal and middle thirds were obtained from 0.5%, 1% PAA groups. Regarding marginal adaptation, 18% HEBP group showed the lowest gap size values (p < 0.05), and better marginal adaptation. Etidronic acid is a promising candidate for final irrigation of root canals. © 2017 Wiley Periodicals, Inc.

  15. Solvent removal and spore inactivation directly in dispensing vials with supercritical carbon dioxide and sterilant.

    PubMed

    Howell, Jahna; Niu, Fengui; McCabe, Shannon E; Zhou, Wei; Decedue, Charles J

    2012-06-01

    A process is described using supercritical carbon dioxide to extract organic solvents from drug solutions contained in 30-mL serum vials. We report drying times of less than 1 h with quantitative recovery of sterile drug. A six-log reduction of three spore types used as biological indicators is achieved with direct addition of peracetic acid to a final concentration of approximately 5 mM (~0.04 %) to the drug solution in the vial. Analysis of two drugs, acetaminophen and paclitaxel, indicated no drug degradation as a result of the treatment. Furthermore, analysis of the processed drug substance showed that no residual peracetic acid could be detected in the final product. We have demonstrated an effective means to simultaneously dry and sterilize active pharmaceutical ingredients from organic solvents directly in a dispensing container.

  16. Abandoning peracetic acid-based dialyzer reuse is associated with improved survival.

    PubMed

    Lacson, Eduardo; Wang, Weiling; Mooney, Ann; Ofsthun, Norma; Lazarus, J Michael; Hakim, Raymond M

    2011-02-01

    Higher mortality risk reported with reuse versus single use of dialyzers is potentially related to reuse reagents that modify membrane surface characteristics and the blood-membrane interface. A key mechanism may involve stimulation of an inflammatory response. In a prospective crossover design, laboratory markers and mortality from 23 hemodialysis facilities abandoning reuse with peracetic acid mixture were tracked. C-reactive protein (CRP), white blood cell (WBC) count, albumin, and prealbumin were measured for 2 consecutive months before abandoning reuse and subsequently within 3 and 6 months on single use. Survival models were utilized to compare the 6-month period before abandoning reuse (baseline) and the 6-month period on single use of dialyzers after a 3-month "washout period." Patients from baseline and single-use periods had a mean age of approximately 63 years; 44% were female, 54% were diabetic, 60% were white, and the mean vintage was approximately 3.2 years. The unadjusted hazard ratio for death was 0.70 and after case-mix adjustment was 0.74 for single use compared with reuse. Patients with CRP≥5 mg/L during reuse (mean CRP=26.6 mg/ml in April) declined on single use to 20.2 mg/L by August and 20.4 mg/L by November. WBC count declined slightly during single use, but nutritional markers were unchanged. Abandonment of peracetic-acid-based reuse was associated with improved survival and lower levels of inflammatory but not nutritional markers. Further study is needed to evaluate a potential link between dialyzer reuse, inflammation, and mortality.

  17. Comparison of four decontamination treatments on porcine renal decellularized extracellular matrix structure, composition, and support of human renal cortical tubular epithelium cells.

    PubMed

    Poornejad, Nafiseh; Nielsen, Jeffery J; Morris, Ryan J; Gassman, Jason R; Reynolds, Paul R; Roeder, Beverly L; Cook, Alonzo D

    2016-03-01

    Engineering whole organs from porcine decellularized extracellular matrix and human cells may lead to a plentiful source of implantable organs. Decontaminating the porcine decellularized extracellular matrix scaffolds is an essential step prior to introducing human cells. However, decontamination of whole porcine kidneys is a major challenge because the decontamination agent or irradiation needs to diffuse deep into the structure to eliminate all microbial contamination while minimizing damage to the structure and composition of the decellularized extracellular matrix. In this study, we compared four decontamination treatments that could be applicable to whole porcine kidneys: 70% ethanol, 0.2% peracetic acid in 1 M NaCl, 0.2% peracetic acid in 4% ethanol, and gamma (γ)-irradiation. Porcine kidneys were decellularized by perfusion of 0.5% (w/v) aqueous solution of sodium dodecyl sulfate and the four decontamination treatments were optimized using segments (n = 60) of renal tissue to ensure a consistent comparison. Although all four methods were successful in decontamination, γ-irradiation was very damaging to collagen fibers and glycosaminoglycans, leading to less proliferation of human renal cortical tubular epithelium cells within the porcine decellularized extracellular matrix. The effectiveness of the other three optimized solution treatments were then all confirmed using whole decellularized porcine kidneys (n = 3). An aqueous solution of 0.2% peracetic acid in 1 M NaCl was determined to be the best method for decontamination of porcine decellularized extracellular matrix. © The Author(s) 2015.

  18. Nine and Ten chemical haloacetic acid mixtures exhibit concentration-dependent departure from dose additivity

    EPA Science Inventory

    Disinfection of water greatly decreases waterborne disease. Disinfection byproducts (DBPs), including haloacetic acids (HAAs), are formed when oxidizing disinfectants react with inorganic and organic matter in water. Water providers routinely assay for 9 HAAs in finished drinking...

  19. Cleaning and Disinfection of Biofilms Composed of Listeria monocytogenes and Background Microbiota from Meat Processing Surfaces

    PubMed Central

    Møretrø, Trond; Heir, Even; Briandet, Romain; Langsrud, Solveig

    2017-01-01

    ABSTRACT Surfaces of food processing premises are exposed to regular cleaning and disinfection (C&D) regimes, using biocides that are highly effective against bacteria growing as planktonic cells. However, bacteria growing in surface-associated communities (biofilms) are typically more tolerant toward C&D than their individual free-cell counterparts, and survival of pathogens such as Listeria monocytogenes may be affected by interspecies interactions within biofilms. In this study, Pseudomonas and Acinetobacter were the most frequently isolated genera surviving on conveyor belts subjected to C&D in meat processing plants. In the laboratory, Pseudomonas, Acinetobacter, and L. monocytogenes dominated the community, both in suspensions and in biofilms formed on conveyor belts, when cultures were inoculated with eleven-genus cocktails of representative bacterial strains from the identified background flora. When biofilms were exposed to daily C&D cycles mimicking treatments used in food industry, the levels of Acinetobacter and Pseudomonas mandelii diminished, and biofilms were instead dominated by Pseudomonas putida (65 to 76%), Pseudomonas fluorescens (11 to 15%) and L. monocytogenes (3 to 11%). The dominance of certain species after daily C&D correlated with high planktonic growth rates at 12°C and tolerance to C&D. In single-species biofilms, L. monocytogenes developed higher tolerance to C&D over time, for both the peracetic acid and quaternary ammonium disinfectants, indicating that a broad-spectrum mechanism was involved. Survival after C&D appeared to be a common property of L. monocytogenes strains, as persistent and sporadic subtypes showed equal survival rates in complex biofilms. Biofilms established preferentially in surface irregularities of conveyor belts, potentially constituting harborage sites for persistent contamination. IMPORTANCE In the food industry, efficient production hygiene is a key measure to avoid the accumulation of spoilage bacteria and eliminate pathogens. However, the persistence of bacteria is an enduring problem in food processing environments. This study demonstrated that environmental bacteria can survive foam cleaning and disinfection (C&D) at concentrations used in the industrial environment. The phenomenon was replicated in laboratory experiments. Important characteristics of persisting bacteria were a high growth rate at low temperature, a tolerance to the cleaning agent, and the ability to form biofilms. This study also supports other recent research suggesting that strain-to-strain variation cannot explain why certain subtypes of Listeria monocytogenes persist in food processing environments while others are found only sporadically. The present investigation highlights the failure of regular C&D and a need for research on improved agents that efficiently detach the biofilm matrix. PMID:28667108

  20. Cleaning and disinfection of biofilms composed of Listeria monocytogenes and background microbiota from meat processing surfaces.

    PubMed

    Fagerlund, Annette; Møretrø, Trond; Heir, Even; Briandet, Romain; Langsrud, Solveig

    2017-06-30

    Surfaces of food processing premises are exposed to regular cleaning and disinfection (C&D) regimes, using biocides that are highly effective against bacteria growing as planktonic cells. However, bacteria growing in surface associated communities (biofilms) are typically more tolerant towards C&D than their individual free cells counterparts, and survival of pathogens such as Listeria monocytogenes may be affected by interspecies interactions within biofilms. In this study, Pseudomonas and Acinetobacter were the most frequently isolated genera surviving on conveyor belts subjected to C&D in meat processing plants. In the laboratory, Pseudomonas , Acinetobacter and L. monocytogenes dominated the community both in suspensions and in biofilms formed on conveyor belts, when cultures were inoculated with eleven-genera cocktails of representative bacterial strains from the identified background flora. When biofilms were exposed to daily C&D cycles, mimicking treatments used in food industry, the levels of Acinetobacter and Pseudomonas mandelii diminished, and biofilms were instead dominated by Pseudomonas putida (65-76%), Pseudomonas fluorescens (11-15%) and L. monocytogenes (3-11%). The dominance of certain species after daily C&D correlated with high planktonic growth rates at 12°C and tolerance to C&D. In single-species biofilms, L. monocytogenes developed higher tolerance to C&D over time, both for the peracetic acid and quaternary ammonium disinfectant, indicating that a broad-spectrum mechanism was involved. Survival after C&D appeared to be a common property of L. monocytogenes strains, as both persistent and sporadic subtypes showed equal survival in complex biofilms. Biofilms established preferentially in surface irregularities of conveyor belts, potentially constituting harborage sites for persistent contamination. IMPORTANCE In food industry, efficient production hygiene is a key measure to avoid accumulation of spoilage bacteria and eliminate pathogens. Persistence of bacteria is however a withstanding problem in food processing environments. This study demonstrated that environmental bacteria can survive foam cleaning and disinfection (C&D) at user concentrations in the industrial environment. The phenomenon was replicated in laboratory experiments. Important characteristics of persisting bacteria were high growth rate at low temperature, tolerance to the cleaning agent and ability to form biofilm. This study also supports other recent research suggesting that strain-to-strain variation cannot explain why certain subtypes of Listeria monocytogenes persist in food processing environments while others are found only sporadically. The present investigation highlights the failure of regular C&D and a need for research on improved agents efficiently detaching the biofilm matrix. Copyright © 2017 American Society for Microbiology.

  1. Decontamination of Bacillus spores adhered to iron and ...

    EPA Pesticide Factsheets

    Journal Article This study examines the effectiveness of decontaminating Bacillus globigii spores attached to corroded iron and cement-mortar coupons with free chlorine at two pH levels, monochloramine, chlorine dioxide, ozone, peracetic acid (PAA) and acidified nitrite, followed by flushing.

  2. OCCURRENCE OF IODO-ACID AND IODO-THM DISINFECTION BY-PRODUCTS IN CHLORAMINATED DRINKING WATER

    EPA Science Inventory

    Iodo-acids were recently identified for the first time as DBPs in drinking water disinfected with chloramines. The iodo-acids identified included iodoacetic acid (IAA), bromoiodoacetic acid, (E)-3-bromo-3-iodo-propenoic acid, (Z)-3-bromo-3-iodo-propenoic acid, and (E)-2-iodo-3...

  3. Combination of peracetic acid and ultrasound reduces Salmonella Typhimurium on fresh lettuce (Lactuca sativa L. var. crispa).

    PubMed

    Silveira, Luiza Oliveira; do Rosário, Denes Kaic Alves; Giori, Ana Carolina Garcia; Oliveira, Syllas Borburema Silva; da Silva Mutz, Yhan; Marques, Clara Suprani; Coelho, Jussara Moreira; Bernardes, Patrícia Campos

    2018-04-01

    Salmonella outbreaks related to fruits and vegetables have been reported being lettuce one of the most contaminated. Peracetic acid (PA) at 50 mg/L, sodium dichloroisocyanurate (SD) at 100 mg/L, and the combination of SD at 100 mg/L and babaçu coconut ( Attalea speciosa ) oil detergent at 100 mg/L were applied to fresh lettuce. Natural contaminant microbiota, physicochemical characteristics, and sensory attributes were evaluated. PA and SD reduced mesophilic aerobic counts by 2.1 and 1.5 log cfu/g, respectively. The most efficient treatment in reducing natural microbiota (i.e., PA) was applied alone and in combination with ultrasound (US). It reduced Salmonella enterica Typhimurium counts to undetectable levels (< 1 log cfu/g). US further reduced S. Typhimurium counts by 0.6 log cfu/g in relation to PA, treatment which lessened the pH but increased the titratable acidity of lettuce, but did not cause total color difference. Therefore, the combination of PA and US holds a potential industrial application for sanitization purposes.

  4. Environmentally Realistic Mixtures of the Five Regulated Haloacetic Acids Exhibit Concentration-Dependent Departures from Dose Additivity

    EPA Science Inventory

    Disinfection of water decreases waterborne disease. Disinfection byproducts (DBPs) are formed by the reaction of oxidizing disinfectants with inorganic and organic materials in the source water. The U.S. EPA regulates five haloacetic acid (HAA) DBPs as a mixture. The objective ...

  5. OCCURRENCE AND TOXICITY OF IODO-ACID AND IODO-THM DBPS IN CHLORAMINATED DRINKING WATER

    EPA Science Inventory

    As part of a recent Nationwide Disinfection By-Product (DBP) Occurrence Study, iodo-acids were identified for the first time as DBPs in drinking water disinfected with chloramines. The iodo-acids identified included iodoacetic acid, bromoiodoacetic acid, (E)-3-bromo-3-iodo-prope...

  6. Tendon allograft sterilized by peracetic acid/ethanol combined with gamma irradiation.

    PubMed

    Zhou, Mo; Zhang, Naili; Liu, Xiaoming; Li, Youchen; Zhang, Yumin; Wang, Xusheng; Li, Baoming; Li, Baoxing

    2014-07-01

    Research and clinical applications have demonstrated that the effects of tendon allografts are comparable to those of autografts when reconstructing injured tendons or ligaments, but allograft safety remains problematic. Sterilisation could eliminate or decrease the possibility of disease transmission, but current methods seldom achieve satisfactory sterilisation without affecting the mechanical properties of the tendon. Peracetic acid-ethanol in combination with low-dose gamma irradiation (PE-R) would inactivate potential deleterious microorganisms without affecting mechanical and biocompatible properties of tendon allograft. Controlled laboratory design. HIV, PPV, PRV and BVDV inactivation was evaluated. After verifying viral inactivation, the treated tendon allografts were characterised by optical microscopy, scanning electron microscopy and tensile testing, and the cytocompatibility was assessed with an MTT assay and by subcutaneous implantation. Effective and efficient inactivation of HIV, PPV, PRV and BVDV was observed. Histological structure and ultrastructure were unchanged in the treated tendon allograft, which also exhibited comparable biomechanical properties and good biocompatibility. The preliminary results confirmed our hypothesis and demonstrated that the PE-R tendon allograft has significant potential as an alternative to ligament/tendon reconstruction. Tendon allografts have been extensively used in ligament reconstruction and tendon repair. However, current sterilisation methods have various shortcomings, so PE-R has been proposed. This study suggests that PE-R tendon allograft has great potential as an alternative for ligament/tendon reconstruction. Sterilisation has been a great concern for tendon allografts. However, most sterilisation methods cannot inactivate viruses and bacteria without impairing the mechanical properties of the tendon allograft. Peracetic acid/ethanol with gamma irradiation can effectively inactivate viruses and bacteria. Meanwhile, tendon allografts sterilised by this method maintain their physiological tendon structure, biomechanical integrity and good compatibility.

  7. Evaluation of the cytotoxicity of elastomeric ligatures after sterilisation with 0.25% peracetic acid.

    PubMed

    Pithon, Matheus Melo; dos Santos, Rogerio Lacerda; Judice, Renata Lima Pasini; de Assuncao, Paulo Sergio; Restle, Luciana

    2013-11-01

    Sterilisation using peracetic acid (PAA) has been advocated for orthodontic elastic bands. However, cane-loaded elastomeric ligatures can also become contaminated during processing, packaging, and manipulation before placement in the oral cavity and are therefore susceptible, and possible causes, of cross-contamination. To test the hypothesis that 0.25% peracetic acid (PAA), following the sterilisation of elastomers, influences the cytotoxicity of elastomeric ligatures on L929 cell lines. Four hundred and eighty silver elastomeric ligatures were divided into 4 groups of 120 ligatures to produce, Group TP (latex natural, bulk pack, TP Orthodontics), Group M1 (Polyurethane, bulk pack, Morelli), Group M2 (Polyurethane, cane-loaded, Morelli) and Group U (Polyurethane, cane-loaded, Uniden). Of the 120 ligatures in each group, 100 were sterilised in 0.25% PAA at time intervals (N = 20) of 1 hour, 2 hours, 3 hours, 4 hours and 5 hours. The 20 remaining elastomeric ligatures in each group were not sterilised and served as controls. Cytotoxicity was assessed using L929 cell lines and a dye-uptake method. Analysis of variance (ANOVA), followed by the Tukey post hoc test (p < 0.05) determined statistical relevance. There was a significant difference between TP, Morelli and Uniden elastomerics (p < 0.05), but no difference between the two types of Morelli elastomerics at the 1 hour time interval. In addition, there was a significant difference between Group CC and the other groups assessed, except between Groups CC and TP at the 1 hour time interval. The non-sterilised elastomeric ligatures showed similar cell viability to that observed after 1 hour of standard sterilisation. PAA did not significantly influence the cytotoxicity of elastomeric ligatures after a sterilisation time of 1 hour and is therefore recommended for clinical use.

  8. Abandoning Peracetic Acid-Based Dialyzer Reuse Is Associated with Improved Survival

    PubMed Central

    Wang, Weiling; Mooney, Ann; Ofsthun, Norma; Lazarus, J. Michael; Hakim, Raymond M.

    2011-01-01

    Summary Background and objectives Higher mortality risk reported with reuse versus single use of dialyzers is potentially related to reuse reagents that modify membrane surface characteristics and the blood-membrane interface. A key mechanism may involve stimulation of an inflammatory response. Design, setting, participants, & measurements In a prospective crossover design, laboratory markers and mortality from 23 hemodialysis facilities abandoning reuse with peracetic acid mixture were tracked. C-reactive protein (CRP), white blood cell (WBC) count, albumin, and prealbumin were measured for 2 consecutive months before abandoning reuse and subsequently within 3 and 6 months on single use. Survival models were utilized to compare the 6-month period before abandoning reuse (baseline) and the 6-month period on single use of dialyzers after a 3-month “washout period.” Results Patients from baseline and single-use periods had a mean age of approximately 63 years; 44% were female, 54% were diabetic, 60% were white, and the mean vintage was approximately 3.2 years. The unadjusted hazard ratio for death was 0.70 and after case-mix adjustment was 0.74 for single use compared with reuse. Patients with CRP ≥ 5 mg/L during reuse (mean CRP = 26.6 mg/ml in April) declined on single use to 20.2 mg/L by August and 20.4 mg/L by November. WBC count declined slightly during single use, but nutritional markers were unchanged. Conclusions Abandonment of peracetic-acid-based reuse was associated with improved survival and lower levels of inflammatory but not nutritional markers. Further study is needed to evaluate a potential link between dialyzer reuse, inflammation, and mortality. PMID:20947788

  9. Peracetic acid oxidation as an alternative pre-treatment for the anaerobic digestion of waste activated sludge.

    PubMed

    Appels, Lise; Van Assche, Ado; Willems, Kris; Degrève, Jan; Van Impe, Jan; Dewil, Raf

    2011-03-01

    Anaerobic digestion is generally considered to be an economic and environmentally friendly technology for treating waste activated sludge, but has some limitations, such as the time it takes for the sludge to be digested and also the ineffectiveness of degrading the solids. Various pre-treatment technologies have been suggested to overcome these limitations and to improve the biogas production rate by enhancing the hydrolysis of organic matter. This paper studies the use of peracetic acid for disintegrating sludge as a pre-treatment of anaerobic digestion. It has been proved that this treatment effectively leads to a solubilisation of organic material. A maximum increase in biogas production by 21% is achieved. High dosages of PAA lead to a decrease in biogas production. This is due to the inhibition of the anaerobic micro-organisms by the high VFA-concentrations. The evolution of the various VFAs during digestion is studied and the observed trends support this hypothesis. Copyright © 2010 Elsevier Ltd. All rights reserved.

  10. Remodeling of ACL Allografts is Inhibited by Peracetic Acid Sterilization

    PubMed Central

    Gonnermann, Johannes; Kamp, Julia; Przybilla, Dorothea; Pruss, Axel

    2008-01-01

    Sterilization of allografts for anterior cruciate ligament (ACL) reconstruction has become an important prerequisite to prevent disease transmission. However, current sterilization techniques impair the biological or mechanical properties of such treated grafts. Peracetic acid (PAA) has been successfully used to sterilize bone allografts without these disadvantages and does not impair the mechanical properties of soft tissue grafts in vitro. We asked whether PAA sterilization would influence recellularization, restoration of crimp length and pattern, and revascularization of ACL grafts during early healing. We used an in vivo sheep model for open ACL reconstruction. We also correlated the histologic findings with the restoration of anteroposterior stability and structural properties during load-to-failure testing. PAA slowed remodeling activity at 6 and 12 weeks compared to nonsterilized allografts and autografts. The mechanical properties of PAA grafts were also reduced compared to these control groups at both time points. We conclude PAA sterilization currently should not be used to sterilize soft tissue grafts typically used in ACL reconstruction. PMID:18491201

  11. Reduced rates of non-union with modified periacetabular osteotomy using peracetic-acid sterilized cancellous allografts.

    PubMed

    Wassilew, Georgi I; Janz, Viktor; Renner, Lisa; Perka, Carsten; Pruss, Axel

    2016-12-01

    The objective of the present study was to analyze the clinical and radiological results of periacetabular osteotomies (PAO) using Kirschner wire fixation and an allogeneic cancellous bone graft. This retrospective cohort study included 73 patients (85 PAOs). The allografts were processed from distal femur of cadaveric donors, defatted, sterilized with a peracetic-acid ethanol solution and freeze-dried. The clinical outcome, as measured by the Harris Hip Scores (HHS), the complication rate and the acetabular correction, as measured by radiological parameters, were compared. The postoperative femoral head coverage and HSS were significantly improved. Major complications occurred in five cases (6 %), but in no case did we observe a non-union or a graft-associated adverse effect. Fixation of the acetabular fragment with Kirschner wires in combination with an allogeneic cancellous bone graft is a safe method, with a low complication rate, no loss of correction and can prevent the occurrence of non-union with a high degree of probability.

  12. [Antiparasitic effects of peracetic acid (PAA) against infective stages (theronts) of white spot disease, Ichthyophthirius multifiliis in vitro].

    PubMed

    Meinelt, T; Staaks, J; Staaks, G; Stüber, A; Bräunig, I

    2007-10-01

    White spot disease, caused by the protozoan parasite Ichthyophthirius multifiliis (I. multifiliis), invades nearly all fresh water fish species and causes huge economic losses. In Germany no protocide substance is legal for the treatment of I. multifilis. As an alternative substance the peracetic acid (PAA) was tested to treat the free invasive stage (theront) of the parasite. PAA concentrations of 0.3 ppm were able to kill all theronts in 120 min in our investigations. As a result of these investigations we recommend an interval-application of 0.3 to 0.5 ppm PAA for 30 to 150 min. This application should be prolonged for two life cycles of the parasite. Biotic parameters as e. g. fish species, and age as well as abiotic parameters as e. g. temperature, pH and organic load of the water could possibly influence the efficiency of the PAA application and should therefore be taken into account while picking the dosage and length of the PAA exposure.

  13. Peracetic acid-ionic liquid pretreatment to enhance enzymatic saccharification of lignocellulosic biomass.

    PubMed

    Uju; Abe, Kojiro; Uemura, Nobuyuki; Oshima, Toyoji; Goto, Masahiro; Kamiya, Noriho

    2013-06-01

    To enhance enzymatic saccharification of pine biomass, the pretreatment reagents peracetic acid (PAA) and ionic liquid (IL) were validated in single reagent pretreatments or combination pretreatments with different sequences. In a 1h saccharification, 5-25% cellulose conversion was obtained from the single pretreatment of PAA or IL. In contrast, a marked enhancement in conversion rates was achieved by PAA-IL combination pretreatments (45-70%). The PAA followed by IL (PAA+IL) pretreatment sequence was the most effective for preparing an enzymatic digestible regenerated biomass with 250-fold higher glucose formation rates than untreated biomass and 2- to 12-fold higher than single pretreatments with PAA or IL alone. Structural analysis confirmed that this pretreatment resulted in biomass with highly porous structural fibers associated with the reduction of lignin content and acetyl groups. Using the PAA+IL sequence, biomass loading in the pretreatment step can be increased from 5% to 15% without significant decrease in cellulose conversion. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. Peracetic Acid Treatment Generates Potent Inactivated Oral Vaccines from a Broad Range of Culturable Bacterial Species

    PubMed Central

    Moor, Kathrin; Wotzka, Sandra Y.; Toska, Albulena; Diard, Médéric; Hapfelmeier, Siegfried; Slack, Emma

    2016-01-01

    Our mucosal surfaces are the main sites of non-vector-borne pathogen entry, as well as the main interface with our commensal microbiota. We are still only beginning to understand how mucosal adaptive immunity interacts with commensal and pathogenic microbes to influence factors such as infectivity, phenotypic diversity, and within-host evolution. This is in part due to difficulties in generating specific mucosal adaptive immune responses without disrupting the mucosal microbial ecosystem itself. Here, we present a very simple tool to generate inactivated mucosal vaccines from a broad range of culturable bacteria. Oral gavage of 1010 peracetic acid-inactivated bacteria induces high-titer-specific intestinal IgA in the absence of any measurable inflammation or species invasion. As a proof of principle, we demonstrate that this technique is sufficient to provide fully protective immunity in the murine model of invasive non-typhoidal Salmonellosis, even in the face of severe innate immune deficiency. PMID:26904024

  15. DISINFECTION BY-PRODUCT FORMATION BY ALTERNATIVE DISINFECTANTS AND REMOVAL BY GRANULAR ACTIVATED CARBON

    EPA Science Inventory

    The effects of the use of the alternative disinfectants on the formation of halogenated disinfection by–products (DBPs) including total organic halide, trihalomethanes, haloacetic acids, haloacetonitriles, haloketones, chloral hydrate, and chloropicrin, were examined along ...

  16. Decontamination of Pangasius fish (Pangasius hypophthalmus) with chlorine or peracetic acid in the laboratory and in a Vietnamese processing company.

    PubMed

    Tong Thi, Anh Ngoc; Sampers, Imca; Van Haute, Sam; Samapundo, Simbarashe; Ly Nguyen, Binh; Heyndrickx, Marc; Devlieghere, Frank

    2015-09-02

    This study evaluated the decontamination of Pangasius fillets in chlorine or peracetic acid treated wash water. First, the decontamination efficacy of the washing step with chlorinated water applied by a Vietnamese processing company during trimming of Pangasius fillets was evaluated and used as the basis for the experiments performed on a laboratory scale. As chlorine was only added at the beginning of the batch and used continuously without renewal for 239min; a rapid increase of the bacterial counts and a fast decrease of chlorine in the wash water were found. This could be explained by the rapid accumulation of organic matter (ca. 400mg O2/L of COD after only 24min). Secondly, for the experiments performed on a laboratory scale, a single batch approach (one batch of wash water for treating a fillet) was used. Chlorine and PAA were evaluated at 10, 20, 50 and 150ppm at contact times of 10, 20 and 240s. Washing with chlorine and PAA wash water resulted in a reduction of Escherichia coli on Pangasius fish which ranged from 0-1.0 and 0.4-1.4logCFU/g, respectively while less to no reduction of total psychrotrophic counts, lactic acid bacteria and coliforms on Pangasius fish was observed. However, in comparison to PAA, chlorine was lost rapidly. As an example, 53-83% of chlorine and 15-17% of PAA were lost after washing for 40s (COD=238.2±66.3mg O2/L). Peracetic acid can therefore be an alternative sanitizer. However, its higher cost will have to be taken into consideration. Where (cheaper) chlorine is used, the processors have to pay close attention to the residual chlorine level, pH and COD level during treatment for optimal efficacy. Copyright © 2015. Published by Elsevier B.V.

  17. Decontamination of minimally invasive surgical endoscopes and accessories.

    PubMed

    Ayliffe, G

    2000-08-01

    (1) Infections following invasive endoscopy are rare and are usually of endogenous origin. Nevertheless, infections do occur due to inadequate cleaning and disinfection and the use of contaminated rinse water and processing equipment. (2) Rigid and flexible operative endoscopes and accessories should be thoroughly cleaned and preferably sterilized using properly validated processes. (3) Heat tolerant operative endoscopes and accessories should be sterilized using a vacuum assisted steam sterilizer. Use autoclavable instrument trays or containers to protect equipment during transit and processing. Small bench top sterilizers without vacuum assisted air removal are unsuitable for packaged and lumened devices. (4) Heat sensitive rigid and flexible endoscopes and accessories should preferably be sterilized using ethylene oxide, low temperature steam and formaldehyde (rigid only) or gas plasma (if appropriate). (5) If there are insufficient instruments or time to sterilize invasive endoscopes, or if no suitable method is available locally, they may be disinfected by immersion in 2% glutaraldehyde or a suitable alternative. An immersion time of at least 10 min should be adopted for glutaraldehyde. This is sufficient to inactivate most vegetative bacteria and viruses including HIV and hepatitis B virus (HBV). Longer contact times of 20 min or more may be necessary if a mycobacterial infection is known or suspected. At least 3 h immersion in glutaraldehyde is required to kill spores. (6) Glutaraldehyde is irritant and sensitizing to the skin, eyes and respiratory tract. Measures must be taken to ensure glutaraldehyde is used in a safe manner, i.e., total containment and/or extraction of harmful vapour and the provision of suitable personal protective equipment, i.e., gloves, apron and eye protection if splashing could occur. Health surveillance of staff is recommended and should include a pre-employment enquiry regarding asthma, skin and mucosal sensitivity problems and lung function testing by spirometry. (7) Possible alternative disinfectants to glutaraldehyde include peracetic acid (0.2-0.35%), chlorine dioxide (700-1100 ppm) and superoxidized water. These are very effective, killing vegetative bacteria, including mycobacteria, and viruses in 5 min and bacterial spores in 10 min. An endorsement of compatibility with endoscopes, accessories and processing equipment is required from both the solution/device manufacturer and the endoscope manufacturer. Other important considerations are stability, cost and safety from the user and environmental standpoints. (8) Cleaning and disinfection or sterilization should be undertaken by trained staff in a dedicated area, e.g., SSD or TSSU. A suitable training programme is described. (9) If endoscopes are processed by immersion in disinfectants, harmful residues must be removed by thorough rinsing. Sterile or bacteria free water is essential for rinsing all invasive endoscopes and accessories to prevent recontamination. (10) If an automated washer disinfector is used it must be effective, non-damaging, reliable, easy to use and its performance regularly monitored. (11) If used, washer disinfectors and other processing equipment should be disinfected on a regular basis, i.e., between patients or at the start of each session. This will prevent biofilm formation and recontamination of instruments during rinsing. Disinfection should include the water treatment system, if present. (12) To comply with the Medical Devices Directive, manufacturers are obliged to provide full details on how to decontaminate the reusable devices they supply. This should include details of compatibility with heat, pressure, moisture, processing chemicals and ultrasonics. (13) The Infection Control Team should always be involved in the formulation and implementation of decontamination policies. Wherever possible, the national good practice guidelines produced by the Medical Devices Agency and/or professional societies shoul

  18. DISINFECTION BY-PRODUCT FORMATION BY ALTERNATIVE DISINFECTANTS AND REMOVAL BY GRANULAR ACTIVATED CARBON

    EPA Science Inventory

    The effects of the use of the alternative disinfectants on the formation of halogenated disinfection by-products (DBPS) including total organic halide, trihalomethanes, haloacetic acids, haloacentonitriles, haloketones, chloral hydrate, and chloropicrin, were examined along with ...

  19. Efficacy of Peracetic acid and Zinc in reducing Campylobacter jejuni on chicken skin

    USDA-ARS?s Scientific Manuscript database

    Campylobacter jejuni is a leading cause of bacterial foodborne disease in humans worldwide, largely associated with the consumption of contaminated poultry products. With increasing consumer demand for natural and minimally processed foods, the use of Generally Recognized as Safe status antimicrobia...

  20. EFFECTS OF 20 WEEK EXPOSURES IN FEMALE SPRAGUE-DAWLEY (S-D) RATS TO DIBROMOACETIC ACID, A DRINKING WATER DISINFECTANT BY-PRODUCT

    EPA Science Inventory

    Effects of 20 week exposures in female Sprague-Dawley (S-D) rats to the drinking water disinfection by-product dibromoacetic acid. A S Murr and J M Goldman, Endocrinol. Br., RTD, NHEERL, ORD, US EPA, Res. Tri. Pk, NC. Sponsor: Audrey Cummings

    The drinking water disinfect...

  1. EFFECTS OF 20 WEEK EXPOSURES IN FEMALE SPRAGUE-DAWLEY (S-D) RATS TO THE DRINKING WATER DISINFECTION BY-PRODUCT DIBROMOACETIC ACID

    EPA Science Inventory

    Effects of 20 week exposures in female Sprague-Dawley (S-D) rats to the drinking water disinfection by-product dibromoacetic acid. A S Murr and J M Goldman, Endocrinol. Br., RTD, NHEERL, ORD, US EPA, Res. Tri. Pk, NC. Sponsor: Audrey Cummings

    The drinking water disinfect...

  2. THE UPTAKE OF WATER DISINFECTION BY-PRODUCTS INTO FOODS DURING HOME PROCESSING

    EPA Science Inventory

    A variety of organic compounds in tap water are produced as a result of disinfection process. Use of chlorine-containing chemicals for disinfection produces many disinfection by-products (DBPs) including trihalomethanes, haloacetonitriles and haloacetic acid. Ozonation with secon...

  3. An IC-MS/MS Method for the Determination of 1-Hydroxyethylidene-1,1-diphosphonic Acid on Uncooked Foods Treated with Peracetic Acid-Based Sanitizers.

    PubMed

    Suzuki, Ippei; Kubota, Hiroki; Ohtsuki, Takashi; Tatebe, Chiye; Tada, Atsuko; Yano, Takeo; Akiyama, Hiroshi; Sato, Kyoko

    2016-01-01

    A rapid, sensitive, and specific analytical method for the determination of 1-hydroxyethylidene-1,1-diphosphonic acid (HEDP) on uncooked foods after treatment with a peracetic acid-based sanitizer (PAS) was developed. The method involves simple sample preparation steps and analysis using ion chromatography (IC) coupled with tandem mass spectrometry (MS/MS). The quantification limits of HEDP on uncooked foods are 0.007 mg/kg for vegetables and fruits and 0.2 mg/kg for meats. The recovery and relative standard deviation (RSD) of HEDP analyses of uncooked foods ranged from 73.9 to 103.8% and 1.9 to 12.6%, respectively. The method's accuracy and precision were evaluated by inter-day recovery tests. The recovery for all samples ranged from 93.6 to 101.2%, and the within-laboratory repeatability and reproducibility were evaluated based on RSD values, which were less than 6.9 and 11.5%, respectively. Analyses of PAS-treated fruits and vegetables using the developed method indicated levels of HEDP ranging from 0.008 to 0.351 mg/kg. Therefore, the results of the present study suggest that the proposed method is an accurate, precise, and reliable way to determine residual HEDP levels on PAS-treated uncooked foods.

  4. Resistance to and killing by the sporicidal microbicide peracetic acid.

    PubMed

    Leggett, Mark J; Schwarz, J Spencer; Burke, Peter A; Mcdonnell, Gerald; Denyer, Stephen P; Maillard, Jean-Yves

    2015-03-01

    To elucidate the mechanisms of spore resistance to and killing by the oxidizing microbicide peracetic acid (PAA). Mutants of Bacillus subtilis lacking specific spore structures were used to identify resistance properties in spores and to understand the mechanism of action of PAA. We also assessed the effect of PAA treatment on a number of spore properties including heat tolerance, membrane integrity and germination. The spore coat is essential for spore PAA resistance as spores with defective coats were greatly sensitized to PAA treatment. Small acid-soluble spore proteins apparently provide no protection against PAA. Defects in spore germination, specifically in germination via the GerB and GerK but not the GerA germination receptors, as well as leakage of internal components suggest that PAA is active at the spore inner membrane. It is therefore likely that the inner membrane is the major site of PAA's sporicidal activity. PAA treatment targets the spore membrane, with some of its activity directed specifically against the GerB and GerK germination receptors. © The Author 2014. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  5. Developmental toxicity of mixtures: the water disinfection by-products dichloro-, dibromo- and bromochloro acetic acid in rat embryo culture

    EPA Science Inventory

    The chlorination of drinking water results in production of numerous disinfection by-products (DBPs). One of the important classes of DBPs is the haloacetic acids. We have previously shown that the haloacetic acids (HAs), dichloro (DCA), dibromo (DBA) and bromochloro (BCA) acetic...

  6. Assessing peracetic acid as a means to control post-vaccination Saprolegniasis in Atlantic salmon Salmo salar parr in recirculation aquaculture systems

    USDA-ARS?s Scientific Manuscript database

    Land-based closed containment facilities, utilizing recirculation aquaculture system (RAS) technologies, can reduce or eliminate the introduction of obligate fish pathogens. Regardless, the presence of opportunistic pathogens must be assumed, and these agents can cause disease during unfavorable con...

  7. Efficient removal of lignin with the maintenance of hemicellulose from kenaf by two-stage pretreatment process.

    PubMed

    Wan Azelee, Nur Izyan; Md Jahim, Jamaliah; Rabu, Amir; Abdul Murad, Abdul Munir; Abu Bakar, Farah Diba; Md Illias, Rosli

    2014-01-01

    The enhancement of lignocellulose hydrolysis using enzyme complexes requires an efficient pretreatment process to obtain susceptible conditions for the enzyme attack. This study focuses on removing a major part of the lignin layer from kenaf (Hibiscus cannabinus) while simultaneously maintaining most of the hemicellulose. A two-stage pretreatment process is adopted using calcium hydroxide, Ca(OH)₂, and peracetic acid, PPA, to break the recalcitrant lignin layer from other structural polysaccharides. An experimental screening of several pretreatment chemicals, concentrations, temperatures and solid-liquid ratios enabled the production of an optimally designed pretreatment process for kenaf. Our results showed that the pretreatment process has provide 59.25% lignin removal while maintaining 87.72% and 96.17% hemicellulose and cellulose, respectively, using 1g of Ca(OH)₂/L and a 8:1 (mL:g) ratio of liquid-Ca(OH)₂ at 50 °C for 1.5 h followed by 20% peracetic acid pretreatment at 75 °C for 2 h. These results validate this mild approach for aiding future enzymatic hydrolysis. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Powerful peracetic acid-ionic liquid pretreatment process for the efficient chemical hydrolysis of lignocellulosic biomass.

    PubMed

    Uju; Goto, Masahiro; Kamiya, Noriho

    2016-08-01

    The aim of this work was to design a new method for the efficient saccharification of lignocellulosic biomass (LB) using a combination of peracetic acid (PAA) pretreatment with ionic liquid (IL)-HCl hydrolysis. The pretreatment of LBs with PAA disrupted the lignin fractions, enhanced the dissolution of LB and led to a significant increase in the initial rate of the IL-HCl hydrolysis. The pretreatment of Bagasse with PAA prior to its 1-buthyl-3-methylimidazolium chloride ([Bmim][Cl])-HCl hydrolysis, led to an improvement in the cellulose conversion from 20% to 70% in 1.5h. Interestingly, the 1-buthyl-3-methylpyridium chloride ([Bmpy][Cl])-HCl hydrolysis of Bagasse gave a cellulose conversion greater than 80%, with or without the PAA pretreatment. For LB derived from seaweed waste, the cellulose conversion reached 98% in 1h. The strong hydrolysis power of [Bmpy][Cl] was attributed to its ability to transform cellulose I to II, and lowering the degree of polymerization of cellulose. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Bacteria-free water for automatic washer-disinfectors: an impossible dream?

    PubMed

    Cooke, R P; Whymant-Morris, A; Umasankar, R S; Goddard, S V

    1998-05-01

    The ability of a new automatic washer-disinfector system (AWDS), fitted with a water filtration system to provide bacteria-free water and so avoid the risk of mycobacterial contamination of fibreoptic bronchoscopes, was examined. Four new Astec 'MP' Safescope washer-disinfectors, with coarse and fine (0.2 micron) filters attached close to the outlet taps, were supplied with non-softened mains water. Water samples from the tank supply and outlet taps were regularly assessed for bacterial quality over a six-month period. Outlet samples were also analysed after fine filter change and purgation with peracetic acid. All bronchoalveolar lavage specimens (BALS) were stained and cultured for mycobacteria. Only 13 out of 53 outlet samples (24%) were culture-negative. There was no improvement after filter change. Residual anti-bacterial effect of peracetic acid lasted up to 48 h following AWDS purgation. No tank samples were bacteria-free. Sixty BALS were processed, two samples were culture-positive and grew M. tuberculosis and one was also smear-positive. Though mycobacterial contamination of bronchoscopes was not evident, the water filtration system was unable to reliably provide sterile rinse water.

  10. [Sporocidic activity of sodium hypochlorite and peracetic acid alone or combined against free or fixed spores or on biofilm].

    PubMed

    Samrakandi, M M; Roques, C; Michel, G

    1994-05-01

    In order to assess the sporocidal activity of chlorine and peracetic acid (PAA), alone and in combination, against a spored biofilm, the biofilms of two species (Bacillus subtilis ATCC 6633 and Bacillus megaterium ATCC 8245) were formed on inert support (tygon). A sporulation kinetic of these bacteria in biofilm was established. Sporocidal properties of chlorine and PAA were compared against free spores, spores fixed by drying and spores in biofilm. The combination of these two products was also tested. Minimal sporocidal concentrations (MSC) of the two products towards free spores were determined (contact time 5 mn). The efficacy of these MSC were evaluated in terms of contact time on adhered spores and on spores in biofilm. Chlorine and PAA exhibited an excellent sporocidal activity. The combination of PAA and chlorine, tested by checkerboard micromethod, was found to be synergistic in case of free or adhered spores. The spored biofilm showed a high resistance. The combination of these two products revealed then only an additive effect.

  11. Virucidal efficacy of disinfectant actives against feline calicivirus, a surrogate for norovirus, in a short contact time.

    PubMed

    Whitehead, Kelly; McCue, Karen A

    2010-02-01

    Among other measures, handwashing and targeted disinfection are important in preventing and controlling norovirus outbreaks. Presently, there are a limited number of disinfectants effective against norovirus. There is a need to develop alternatives to bleach that are effective against norovirus, and, in particular, fast-acting disinfectants are desired. The aim of this study was to determine the disinfectant actives and formulation factors necessary to achieve efficacy against norovirus in a short contact time. Feline calicivirus (FCV) was used as a surrogate for norovirus. In a carrier test method, common disinfectant actives including alcohol, acid, quaternary compound, and phenol both alone and as formulated disinfectants were contacted with dried FCV virus for 1 minute. The virus treatment was neutralized and assayed in Crandell-Reese kidney cells for cytopathic effect. Log(10) virus inactivation was calculated comparing treatment results to virus control titer. Bleach and acid-based disinfectants inactivate FCV in 1 minute. Inactivation of FCV by alcohol and quaternary actives depends on how these actives are formulated as disinfectants. Actives and extreme pH are determined predictive of efficacy. Ethanol and quaternary compounds formulated at appropriate concentration and alkaline pH inactivates FCV in 1-minute contact. Acid cleaners, ethanol, and quaternary compounds formulated at appropriate concentration and pH can be fast-acting antimicrobial choices and alternatives to bleach for the consumer and health care providers to use to inactivate FCV, a surrogate for norovirus, and protect against this important pathogen. Copyright 2010 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  12. Environmentally Realistic Mixtures of Haloacetic Acids Exhibit Concentration-Dependent Departures from Dose Additivity

    EPA Science Inventory

    Disinfection byproducts (DBPs), including haloacetic acids (HAAs), are formed when oxidizing disinfectants react with inorganic and organic matter in water. Drinking water is assayed routinely for 9 HAAs (HAA9): chloro-, dichloro-, trichloro-, bromo-, dibromo-, tribrorno-, bromoc...

  13. CHRONIC EXPOSURE TO DIBROMOACETIC ACID, A WATER DISINFECTION BY-PRODUCT, DIMINISHES PRIMORDIAL FOLLICLES IN THE RABBIT

    EPA Science Inventory

    Exposure to dibromoacetic acid (DBA), a commonly occurring water disinfection by-product, has detrimental effects on spermatogenesis and fertility in rats and rabbits. Despite indications of important reproductive consequences of DBA exposure in males, reproductive sequelae follo...

  14. ENANTIOMERIC COMPOSITION OF CHIRAL HALOACETIC ACID AND HALOACETONITRILE DISINFECTION BYPRODUCTS IN DRINKING WATER

    EPA Science Inventory

    Haloacetic acids and haloacetonitriles are well-known chlorine disinfection byproducts (DBPs), formed by the reaction of chlorine with natural organic matter. These compounds are of concern to public health because of their possible toxicological properties. Studies to date on th...

  15. Monohaloacetic acid drinking water disinfection by-products inhibit follicle growth and steroidogenesis in mouse ovarian antral follicles in vitro.

    PubMed

    Jeong, Clara H; Gao, Liying; Dettro, Tyler; Wagner, Elizabeth D; Ricke, William A; Plewa, Michael J; Flaws, Jodi A

    2016-07-01

    Water disinfection greatly reduced the incidence of waterborne diseases, but the reaction between disinfectants and natural organic matter in water leads to the formation of drinking water disinfection by-products (DBPs). DBPs have been shown to be toxic, but their effects on the ovary are not well defined. This study tested the hypothesis that monohalogenated DBPs (chloroacetic acid, CAA; bromoacetic acid, BAA; iodoacetic acid, IAA) inhibit antral follicle growth and steroidogenesis in mouse ovarian follicles. Antral follicles were isolated and cultured with either vehicle or DBPs (0.25-1.00mM of CAA; 2-15μM of BAA or IAA) for 48 and 96h. Follicle growth was measured every 24h and the media were analyzed for estradiol levels at 96h. Exposure to DBPs significantly inhibited antral follicle growth and reduced estradiol levels compared to controls. These data demonstrate that DBP exposure caused ovarian toxicity in vitro. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Monohaloacetic acid drinking water disinfection by-products inhibit follicle growth and steroidogenesis in mouse ovarian antral follicles in vitro

    PubMed Central

    Jeong, Clara H.; Gao, Liying; Dettro, Tyler; Wagner, Elizabeth D.; Ricke, William A.; Plewa, Michael J.; Flaws, Jodi A.

    2016-01-01

    Water disinfection greatly reduced the incidence of waterborne diseases, but the reaction between disinfectants and natural organic matter in water leads to the formation of drinking water disinfection by-products (DBPs). DBPs have been shown to be toxic, but their effects on the ovary are not well defined. This study tested the hypothesis that monohalogenated DBPs (chloroacetic acid, CAA; bromoacetic acid, BAA; iodoacetic acid, IAA) inhibit antral follicle growth and steroidogenesis in mouse ovarian follicles. Antral follicles were isolated and cultured with either vehicle or DBPs (0.25–1.00 mM of CAA; 2–15 µM of BAA or IAA) for 48 and 96 h. Follicle growth was measured every 24 h and the media were analyzed for estradiol levels at 96 h. Exposure to DBPs significantly inhibited antral follicle growth and reduced estradiol levels compared to controls. These data demonstrate that DBP exposure caused ovarian toxicity in vitro. PMID:27151372

  17. A comparison of the virucidal properties of chlorine, chlorine dioxide, bromine chloride and iodine.

    PubMed Central

    Taylor, G. R.; Butler, M.

    1982-01-01

    Chlorine dioxide, bromine chloride and iodine were compared with chlorine as virucidal agents. Under optimal conditions all disinfectants were effective at low concentrations, but each disinfectant responded differently to acidity and alkalinity. Disinfection by chlorine was impaired by the presence of ammonia, but the other disinfectants retained much of their potency. Disinfection of poliovirus by iodine resulted in structural changes in the virions as seen by electron micrroscopy, but the other disinfectants were able to inactivate poliovirus without causing any apparent structural changes. Images Plate 1 PMID:6290566

  18. Thiazolidine peracetates: Novel carbohydrate derivatives that assign cis-2,3- from trans-2,3- monosaccharides by GC/MS analysis

    USDA-ARS?s Scientific Manuscript database

    A new type of carbohydrate derivative is described that is suitable for analysis by GC/MS. Reaction of free aldoses (pentoses or hexoses), or the component aldoses arising from acid hydrolysis of polysaccharides or oligosaccharides, with excess cysteamine hydrochloride in pyridine, results in the qu...

  19. Investigating the effectiveness of peracetic acid to reduce post-vaccination Saprolegnia spp.-associated mortality in Atlantic salmon parr while assessing impact on nitrification in recirculation aquaculture systems

    USDA-ARS?s Scientific Manuscript database

    Closed containment operations utilizing recirculation aquaculture systems (RAS) can provide critical barriers to the introduction of obligate fish pathogens (Timmons and Ebeling, 2010); however, opportunistic pathogens will be present and can cause disease when conditions favor these agents. One par...

  20. Assessing the effectiveness of peracetic acid to remediate post-vaccination Saprolegnia spp.-associated mortality in Atlantic salmon Salmo salar parr in recirculation aquaculture systems

    USDA-ARS?s Scientific Manuscript database

    Disease is a major barrier to aquaculture production worldwide, and within the salmon industry it is responsible for the majority of market supply fluctuation. Ubiquitous oomycetes of the Saprolegnia genus are particularly problematic disease agents, associated with an estimated 10% mortality among ...

  1. ALTERED GENE EXPRESSION OF MOUSE EMBRYO CULTURES EXPOSED TO BROMOCHLOROACETIC ACID

    EPA Science Inventory

    An unintended consequence of chemical disinfection of municipal drinking water has been the production of disinfection by-products (DBPs) resulting from the interaction of chemical disinfectants and naturally occurring organic material present in the water. A major class of the ...

  2. Assessment of Diiodoacetic Effects on Eye Malformations in a Developmental Toxicity Screen with F344 Rats

    EPA Science Inventory

    Diiodoacetic acid (DIA) is an iodinated haloacetic acid and a drinking water disinfection by-product (DBP) formed in drinking water treated by chloramination (chlorine plus ammonia) to prevent microbial contamination and regrowth. Although disinfection of drinking water has prove...

  3. Rx for H20

    ERIC Educational Resources Information Center

    Yapijakis, Costas

    1978-01-01

    Drinking water disinfectants are discussed. Disinfectants are chlorine, chlorine dioxide, ozone, potassium permanganate, iodine, bromine, hydrogen peroxide; silver, acids and bases, ultraviolet radiation. (MR)

  4. INHIBITION OF NEURAL CREST CELL MIGRATION BY THE WATER DISINFECTION BYPRODUCTS DICHLORO-, DIBROMO-, AND BROMOCHLORO-ACETIC ACID.

    EPA Science Inventory

    INHIBITION OF NEURAL CREST CELL MIGRATION BY THE WATER DISINFECTION BYPRODUCTS DICHLORO-, DIBROMO- AND BROMOCHLORO-ACETIC ACID. JE Andrews, H Nichols, J Schmid 1, and ES Hunter. Reproductive Toxicology Division, 1Research Support Division, NHEERL, USEPA, RTP, NC, USA.

    ...

  5. Influence of ultrasound enhancement on chlorine dioxide consumption and disinfection by-products formation for secondary effluents disinfection.

    PubMed

    Zhou, Xiaoqin; Zhao, Junyuan; Li, Zifu; Lan, Juanru; Li, Yajie; Yang, Xin; Wang, Dongling

    2016-01-01

    Chlorine dioxide (ClO2) has been promoted as an alternative disinfectant because of its high disinfection efficiency and less formation of organic disinfection by-products (DBPs). However, particle-associated microorganisms could be protected during the disinfection process, which decreases the disinfection efficiency or increases the required dosage. Besides, the formation of inorganic disinfection by-products is a significant concern in environment health. Ultrasound (US)-combined disinfection methods are becoming increasingly attractive because they are efficient and environmentally friendly. In this study, US was introduced as an enhancement method to identify its influence on ClO2 demand reduction and to minimize the production of potential DBPs for secondary effluents disinfection. Fecal coliform was used as an indicator, and DBPs, including trichloromethane (TCM), dichloroacetic acid (DCAA), trichloroacetic acid (TCAA), chlorite (ClO2(-)), and chlorate (ClO3(-)), were analyzed to observe the potential DBPs formation. Results show that US pretreatment could reduce half of ClO2 dosage compared with ClO2 disinfection alone for the same disinfection efficiency, and that an input power density of 2.64 kJ/L pretreatment with the 1.5mg/L ClO2 was enough to meet the discharge requirement in China (i.e., fecal coliform below 1000 CFU/L for Class 1A) for secondary effluent disinfection, and the ClO2(-) concentration in the disinfection effluent was only 1.37 mg/L at the same time. Furthermore, the different effects of US on the two processes (US as pretreatment and simultaneous US/ClO2 disinfection) were also analyzed, including deagglomerating, cell damage, and synergistic disinfection as well as degasing/sonolysis. It was proved that the production of TCM, DCAA, and TCAA was insignificantly influenced with the introduction of US, but US pretreatment did reduce the production of ClO2(-) and ClO3(-) effectually. In general, US pretreatment could be a better option for disinfection enhancement methods combined with ClO2 in terms of both disinfection efficiency and disinfection by-product formation. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. The wide spectrum high biocidal potency of Bioxy formulation when dissolved in water at different concentrations

    PubMed Central

    Dagher, Fadi

    2017-01-01

    Traditional surface disinfectants that have long been applied in medicine, animal husbandry, manufacturing and institutions are inconvenient at best and dangerous at worst. Moreover, some of these substances have adverse environmental impacts: for example, quaternary ammonium compounds (“quats”) are reproductive toxicants in both fish and mammals. Halogens are corrosive both to metals and living tissues, are highly reactive, can be readily neutralized by metals, and react with organic matter to form toxic, persistent by-products such as dioxins and furans. Aldehydes may be carcinogenic to both human and animals upon repeated exposures, are corrosive, cross-link living tissues and many synthetic materials, and may lose efficacy when pathogens enzymatically adapt to them. Alcohols are flammable and volatile and can be enzymatically degraded by certain bacterial pathogens. Quats are highly irritating to mucous membranes and over time can induce pathogen resistance, especially if they are not alternated with functionally different disinfectants. In contrast, peracetic acid (PAA), a potent oxidizer, liberates hydrogen peroxide (itself a disinfectant), biodegrades to carbon dioxide, water and oxygen, and is at least as efficacious as contact biocides e.g., halogens and aldehydes. Nevertheless, the standard form of liquid PAA is highly corrosive, is neutralized by metals and organic matter, gives off noxious odours and must be stored in vented containers. For the reasons stated above, Bioxy formulations were developed, a series of powder forms of PAA, which are odourless, stable in storage and safe to transport and handle. They generate up to 10% PAA in situ when dissolved in water. A 0.2% aqueous solution of Bioxy (equivalent to 200 ppm PAA) effected a 6.76 log reduction in Methicillin-resistant Staphylococcus aureus (MRSA) within 2 minutes after application. A 5% aqueous solution of Bioxy achieved a 3.93 log reduction in the bovine tuberculosis bacillus Mycobacterium bovis, within 10 minutes after contact. A 1% solution of Bioxy reduced vancomycin-resistant enterococci (VRE) and Pseudomonas aeruginosa by 6.31 and 7.18 logs, respectively, within 3 minutes after application. A 0.5% solution of Bioxy inactivated porcine epidemic diarrhea virus (PEDV) within 15 minutes of contact, and a 5% solution of Bioxy realized a 5.36 log reduction in the spores of Clostridium difficile within 10 minutes of application. In summary, Bioxy is safe and easy to transport and store, poses negligible human, animal and environmental health risks, shows high levels of pathogen control efficacy and does not induce microbial resistance. Further investigations are recommended to explore its use as an industrial biocide. PMID:28207828

  7. The wide spectrum high biocidal potency of Bioxy formulation when dissolved in water at different concentrations.

    PubMed

    Dagher, Dori; Ungar, Ken; Robison, Richard; Dagher, Fadi

    2017-01-01

    Traditional surface disinfectants that have long been applied in medicine, animal husbandry, manufacturing and institutions are inconvenient at best and dangerous at worst. Moreover, some of these substances have adverse environmental impacts: for example, quaternary ammonium compounds ("quats") are reproductive toxicants in both fish and mammals. Halogens are corrosive both to metals and living tissues, are highly reactive, can be readily neutralized by metals, and react with organic matter to form toxic, persistent by-products such as dioxins and furans. Aldehydes may be carcinogenic to both human and animals upon repeated exposures, are corrosive, cross-link living tissues and many synthetic materials, and may lose efficacy when pathogens enzymatically adapt to them. Alcohols are flammable and volatile and can be enzymatically degraded by certain bacterial pathogens. Quats are highly irritating to mucous membranes and over time can induce pathogen resistance, especially if they are not alternated with functionally different disinfectants. In contrast, peracetic acid (PAA), a potent oxidizer, liberates hydrogen peroxide (itself a disinfectant), biodegrades to carbon dioxide, water and oxygen, and is at least as efficacious as contact biocides e.g., halogens and aldehydes. Nevertheless, the standard form of liquid PAA is highly corrosive, is neutralized by metals and organic matter, gives off noxious odours and must be stored in vented containers. For the reasons stated above, Bioxy formulations were developed, a series of powder forms of PAA, which are odourless, stable in storage and safe to transport and handle. They generate up to 10% PAA in situ when dissolved in water. A 0.2% aqueous solution of Bioxy (equivalent to 200 ppm PAA) effected a 6.76 log reduction in Methicillin-resistant Staphylococcus aureus (MRSA) within 2 minutes after application. A 5% aqueous solution of Bioxy achieved a 3.93 log reduction in the bovine tuberculosis bacillus Mycobacterium bovis, within 10 minutes after contact. A 1% solution of Bioxy reduced vancomycin-resistant enterococci (VRE) and Pseudomonas aeruginosa by 6.31 and 7.18 logs, respectively, within 3 minutes after application. A 0.5% solution of Bioxy inactivated porcine epidemic diarrhea virus (PEDV) within 15 minutes of contact, and a 5% solution of Bioxy realized a 5.36 log reduction in the spores of Clostridium difficile within 10 minutes of application. In summary, Bioxy is safe and easy to transport and store, poses negligible human, animal and environmental health risks, shows high levels of pathogen control efficacy and does not induce microbial resistance. Further investigations are recommended to explore its use as an industrial biocide.

  8. Occurrence of carboxylic acids in different steps of two drinking-water treatment plants using different disinfectants.

    PubMed

    Jurado-Sánchez, Beatriz; Ballesteros, Evaristo; Gallego, Mercedes

    2014-03-15

    The occurrence of 35 aliphatic and aromatic carboxylic acids within two full scale drinking-water treatment plants was evaluated for the first time in this research. At the intake of each plant (raw water), the occurrence of carboxylic acids varied according to the quality of the water source although in both cases 13 acids were detected at average concentrations of 6.9 and 4.7 μg/L (in winter). In the following steps in each treatment plant, the concentration patterns of these compounds differed depending on the type of disinfectant applied. Thus, after disinfection by chloramination, the levels of the acids remained almost constant (average concentration, 6.3 μg/L) and four new acids were formed (butyric, 2-methylbutyric, 3-hydroxybenzoic and 2-nitrobenzoic) at low levels (1.1-5 μg/L). When ozonation/chlorination was used, the total concentration of the carboxylic acids in the raw water sample (4.7 μg/L) increased up to 6 times (average concentration, 26.3 μg/L) after disinfection and 6 new acids (mainly aromatic) were produced at high levels (3.5-100 μg/L). Seasonal variations of the carboxylic acids under study showed that in both plants, maximum levels of all the analytes were reached in the coldest months (autumn and winter), aromatic acids only being found in those seasons. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Resistance of bacterial biofilms formed on stainless steel surface to disinfecting agent.

    PubMed

    Królasik, Joanna; Zakowska, Zofia; Krepska, Milena; Klimek, Leszek

    2010-01-01

    The natural ability of microorganisms for adhesion and biofilm formation on various surfaces is one of the factors causing the inefficiency of a disinfection agent, despite its proven activity in vitro. The aim of the study was to determine the effectiveness of disinfecting substances on bacterial biofilms formed on stainless steel surface. A universally applied disinfecting agent was used in the tests. Bacterial strains: Listeria innocua, Pseudomonas putida, Micrococcus luteus, Staphylococcus hominis strains, were isolated from food contact surfaces, after a cleaning and disinfection process. The disinfecting agent was a commercially available acid specimen based on hydrogen peroxide and peroxyacetic acid, the substance that was designed for food industry usage. Model tests were carried out on biofilm formed on stainless steel (type 304, no 4 finish). Biofilms were recorded by electron scanning microscope. The disinfecting agent in usable concentration, 0.5% and during 10 minutes was ineffective for biofilms. The reduction of cells in biofilms was only 1-2 logarithmic cycles. The use of the agent in higher concentration--1% for 30 minutes caused reduction of cell number by around 5 logarithmic cycles only in the case of one microorganism, M. luteus. For other types: L. innocua, P. putida, S. hominis, the requirements placed on disinfecting agents were not fulfilled. The results of experiments proved that bacterial biofilms are resistant to the disinfectant applied in its operational parameters. Disinfecting effectiveness was achieved after twofold increase of the agent's concentration.

  10. TRIBROMOPYRROLE, BROMINATED ACIDS, AND OTHER DISINFECTION BYPRODUCTS PRODUCED BY DISINFECTION OF DRINKING WATER RICH IN BROMIDE

    EPA Science Inventory

    Using gas chromatography/mass spectrometry (GC/MS), we investigated the formation of disinfection byproducts (DBPs) from high bromide waters (2 mg/L) treated with chlorine or chlorine dioxide used in combination with chlorine and chloramines. This study represents the first comp...

  11. Effects of pulsed electrical field processing on microbial survival, quality change and nutritional characteristics of blueberries

    USDA-ARS?s Scientific Manuscript database

    Whole fresh blueberries were treated using a parallel pulsed electric field (PEF) treatment chamber and a sanitizer solution (60 ppm peracetic acid [PAA]) as PEF treatment medium with square wave bipolar pulses at 2 kV/cm electric field strength, 1us pulse width, and 100 pulses per second for 2, 4, ...

  12. IMMUNOTOXICITY OF DlBROMOACETIC ACID ADMINISTERED VIA DRINKING WATER TO FEMALE B6C3Fl MICE

    EPA Science Inventory

    Dibromoacetic acid (DBA) is a disinfection by product commonly found in drinking water as a result of chlorination/ozonation processes. The EPA estimates that more than 200 million people consume disinfected water in the U.S. (EPA 1998). This study was conducted to evaluate the p...

  13. INFLUENCE OF THE DRINKING WATER DISINFECTION BY-PRODUCT DIBROMOACETIC ACID ON RAT ESTROUS CYCLICITY AND OVARIAN FOLLICULAR STEROID RELEASE IN VITRO

    EPA Science Inventory

    The drinking water disinfection by-product, dibromoacetic acid (DBA) has been reported to affect gonadal functions in the male rat. However, there is little information regarding its influence on female reproductive activity. Consequently, the present study investigated the eff...

  14. ALTERATION OF ESTROUS CYCLICITY BY THE DRINKING WATER DISINFECTION BY-PRODUCT DIBROMOACETIC ACID: RELATIONSHIP TO AN EFFECT ON ESTRADIOL METABOLISM?

    EPA Science Inventory

    A number of chemicals formed by disinfection of municipal drinking water have been suspected to cause reproductive alterations in humans and test animals. One class of these chemicals, the haloacetic acids, have been reported to alter a number of rat testicular endpoints, includ...

  15. DISRUPTION IN RAT ESTROUS CYCLICITY BY THE DRINKING WATER DISINFECTANT BY-PRODUCT DIBROMOACETIC ACID: RELATIONSHIP TO A SUPPRESSION ON ESTRADIOL METABOLISM?

    EPA Science Inventory

    Disruption in Rat Estrous Cyclicity by the Drinking Water Disinfectant By-Product Dibromoacetic Acid: Relationship to A Suppression on Estradiol Metabolism?

    Ashley S. Murr and Jerome M. Goldman, Endocrinology Branch, Reproductive Toxicology Division National Health and En...

  16. MODULATION OF THE CYTOTOXICITY AND GENOTOXICITY OF THE DRINKING WATER DBP IODOACETIC ACID BY SUPPRESSORS OF OXIDATIVE STRESS

    EPA Science Inventory

    Drinking water disinfection by-products (DBPs) are generated by the chemical disinfection of water and may pose a hazard to the public health. Previously we demonstrated that iodoacetic acid was the most cytotoxic and genotoxic DBP analyzed in a mammalian cell system. Little is k...

  17. Do Iodine Contrast Media Compounds Used for Medical Imaging Contribute to the Formation of Iodinated Disinfection By-Products in Drinking Water?

    EPA Science Inventory

    Iodinated disinfection byproducts (DBPs) have recently gained attention due to their cyto- and genotoxicity and increased formation in drinking water treated with chloramine, which has become an increasingly popular disinfectant in the United States. One of these—iodoacetic acid...

  18. Characterization of Salmonella enterica isolates from turkeys in commercial processing plants for resistance to antibiotics, disinfectants, and a growth promoter

    USDA-ARS?s Scientific Manuscript database

    Salmonella enterica serovars isolated from turkeys in commercial processing plants were characterized for susceptibility to antibiotics, disinfectants, disinfectant components, and the organoarsenical growth promotant 4-hydroxy-3-nitrophenylarsonic acid (3-NHPAA) and its metabolites NaAsO2 (As[III])...

  19. Significance of pH on the Cytotoxic Potential of the Water Disinfection By-Product Iodoacetic Acid

    EPA Science Inventory

    Significance of pH on the Cytotoxic Potential of the Water Disinfection By-Product Iodoacetic Acid Vicki Richardson1, Susan D. Richardson2, Mary Moyer3, Jane Ellen Simmons1, and Anthony DeAngelo1, 1U.S. Environmental Protection Agency, Research Triangle Park, NC, 2University of...

  20. REPRODUCTIVE AND GENOMIC EFFECTS IN TESTES FROM MICE EXPOSED TO THE WATER DISINFECTANT BYPRODUCT BROMOCHLOROACETIC ACID

    EPA Science Inventory

    ABSTRACT

    A byproduct of drinking water disinfection, bromochloroacetic acid (BCA), acts as a reproductive toxicant in rats. To determine if BCA produces similar reproductive toxicity in mice, juvenile and adult C57BL/6 males were exposed to 0, 8, 24, 72 or 216 mg/kg of BC...

  1. REPRODUCTIVE EFFECTS OF THE WATER DISINFECTANT BYPRODUCT BROMOCHLOROACETIC ACID (BCA) IN ADULT AND JUVENILE MALE C57BL/6 MICE

    EPA Science Inventory

    REPRODUCTIVE EFFECTS OF THE WATER DISINFECTANT BYPRODUCT BROMOCHLOROACETIC ACID (BCA) IN ADULT AND JUVENILE MALE C57BL/6 MICE.
    JC Rockett, JC Luft, JB Garges and DJ Dix. Reproductive Toxicology Division, USEPA, RTP, NC, USA.
    Sponsor: G Klinefelter
    The development of wate...

  2. TWENTY WEEK EXPOSURES TO THE DRINKING WATER DISINFECTION BY-PRODUCT DIBROMOACETIC ACID: REPRODUCTIVE CYCLICITY AND STEROID CONCENTRATIONS IN THE FEMALE SPRAGUE-DAWLEY RAT

    EPA Science Inventory

    Abstract
    Elevated gavage exposures to the drinking water disinfection by-product dibromoacetic acid (DBA) have been found to disrupt estrous cyclicity in the rat and induce increases in estradiol concentrations in both cycling (day of estrus) and ovariectomized/estradiol-impla...

  3. DIBROMOACETIC ACID, A PREVALENT BY-PRODUCT OF DRINKING WATER DISINFECTION, COMPROMISES THE SYNTHESIS OF SPECIFIC SEMINFEROUS TUBULE PROTEINS FOLLOWING BOTH IN VIVO AND IN VITRO EXPOSURES

    EPA Science Inventory

    ABSTRACT
    Dibromoacetic acid(DBA) is a byproduct of drinking water disinfection that alters spermatogenesis in adult male rats. To identify a mechanism by which DBA alters spermatogenesis, seminiferous tubules representing specific groups of spermatogenic stages were expos...

  4. [On the bactericidal action of dibromoisocyanuric acid; experiments concerning the disinfection of hands (author's transl)].

    PubMed

    Gottardi, W; Puritscher, M

    1976-07-01

    The action of dibromoisocyanuric acid (DBI), C12, Br2, trichloroisocyanuric acid (TCI) and chloramine T against Staph. aureus SG 511 was compared. Using the suspension test DBI and Br2 showed the strongest, chloramine T however, the weakest bactericidal power (Tab 2). Under the conditions of the "Hygienic disinfection of hands" a 0.005 M solution of DBI met the requirements specified in the "Richtlinien für die Prüfung chemischer Desinfektionsmittel" (3. Ed., Stuttgart: Gustav Fischer Verlag, 1972), and was comparable to a chloramine T solution containing the same amount of active halogen (Tab. 3). The decrease of disinfection power compared with the suspension test can be attributed to a great error induced by protein.

  5. Assessment of Damage to Nucleic Acids and Repair Machinery in Salmonella typhimurium Exposed to Chlorine

    PubMed Central

    Phe, M. H.; Hajj Chehade, M.; Guilloteau, H.; Merlin, C.; Block, J. C.

    2009-01-01

    Water disinfection is usually evaluated using mandatory methods based on cell culturability. However, such methods do not consider the potential of cells to recover, which should also be kept as low as possible. In this paper, we hypothesized that a successful disinfection is achieved only when the applied chlorine leads to both intracellular nucleic acid damage and strong alterations of the DNA repair machinery. Monitoring the SOS system responsiveness with a umuC’-‘lacZ reporter fusion, we found that the expression of this important cellular machinery was altered after the beginning of membrane permeabilization but prior to the total decline of both the cell culturability and the nucleic acid integrity as revealed by Sybr-II staining. Rapid measurement of such nucleic acid alterations by fluorochrome-based staining could be used as an alternative method for assessing the effectiveness of disinfection with chlorine. PMID:19936107

  6. MODERATING INFLUENCE OF THE DRINKING WATER DISINFECTION BY-PRODUCT DIBROMOACETIC ACID ON A DITHIOCARBAMATE-INDUCED SUPPRESSION OF THE LUTEINIZING HORMONE SURGE IN FEMALE RATS.

    EPA Science Inventory

    The disinfection by-product dibromoacetic acid (DBA) has been found in female rats to increase circulating concentrations of both estradiol (E2) and estrone (E1). This effect is apparently due, at least in part, to a suppression in hepatic catabolism. The present study investigat...

  7. Enhancement of hydrolysis of Chlorella vulgaris by hydrochloric acid.

    PubMed

    Park, Charnho; Lee, Ja Hyun; Yang, Xiaoguang; Yoo, Hah Young; Lee, Ju Hun; Lee, Soo Kweon; Kim, Seung Wook

    2016-06-01

    Chlorella vulgaris is considered as one of the potential sources of biomass for bio-based products because it consists of large amounts of carbohydrates. In this study, hydrothermal acid hydrolysis with five different acids (hydrochloric acid, nitric acid, peracetic acid, phosphoric acid, and sulfuric acid) was carried out to produce fermentable sugars (glucose, galactose). The hydrothermal acid hydrolysis by hydrochloric acid showed the highest sugar production. C. vulgaris was hydrolyzed with various concentrations of hydrochloric acid [0.5-10 % (w/w)] and microalgal biomass [20-140 g/L (w/v)] at 121 °C for 20 min. Among the concentrations examined, 2 % hydrochloric acid with 100 g/L biomass yielded the highest conversion of carbohydrates (92.5 %) into reducing sugars. The hydrolysate thus produced from C. vulgaris was fermented using the yeast Brettanomyces custersii H1-603 and obtained bioethanol yield of 0.37 g/g of algal sugars.

  8. Bacteriocidal activity of sanitizers against Enterococcus faecium attached to stainless steel as determined by plate count and impedance methods.

    PubMed

    Andrade, N J; Bridgeman, T A; Zottola, E A

    1998-07-01

    Enterococcus faecium attached to stainless steel chips (100 mm2) was treated with the following sanitizers: sodium hypochlorite, peracetic acid (PA), peracetic acid plus an organic acid (PAS), quaternary ammonium, organic acid, and anionic acid. The effectiveness of sanitizer solutions on planktonic cells (not attached) was evaluated by the Association of Official Analytical Chemists (AOAC) suspension test. The number of attached cells was determined by impedance measurement and plate count method after vortexing. The decimal reduction (DR) in numbers of the E. faecium population was determined for the three methods and was analyzed by analysis of variance (P < 0.05) using Statview software. The adhered cells were more resistant (P < 0.05) than nonadherent cells. The DR averages for all of the sanitizers for 30 s of exposure were 6.4, 2.2, and 2.5 for the AOAC suspension test, plate count method after vortexing, and impedance measurement, respectively. Plate count and impedance methods showed a difference (P < 0.05) after 30 s of sanitizer exposure but not after 2 min. The impedance measurement was the best method to measure adherent cells. Impedance measurement required the development of a quadratic regression. The equation developed from 82 samples is as follows: log CFU/chip = 0.2385T2-0.96T + 9.35, r2 = 0.92, P < 0.05, T = impedance detection time in hours. This method showed that the sanitizers PAS and PA were more effective against E. faecium than the other sanitizers. At 30 s, the impedance method recovered about 25 times more cells than the plate count method after vortexing. These data suggest that impedance measurement is the method of choice when evaluating the number of bacterial cells adhered to a surface.

  9. Bromination of Marine Dissolved Organic Matter following Full Scale Electrochemical Ballast Water Disinfection.

    PubMed

    Gonsior, Michael; Mitchelmore, Carys; Heyes, Andrew; Harir, Mourad; Richardson, Susan D; Petty, William Tyler; Wright, David A; Schmitt-Kopplin, Philippe

    2015-08-04

    An extensively diverse array of brominated disinfection byproducts (DBPs) were generated following electrochemical disinfection of natural coastal/estuarine water, which is one of the main treatment methods currently under consideration for ballast water treatment. Ultra-high-resolution mass spectrometry revealed 462 distinct brominated DBPs at a relative abundance in the mass spectra of more than 1%. A brominated DBP with a relative abundance of almost 22% was identified as 2,2,4-tribromo-5-hydroxy-4-cyclopentene-1,3-dione, which is an analogue to several previously described 2,2,4-trihalo-5-hydroxy-4-cyclopentene-1,3-diones in drinking water. Several other brominated molecular formulas matched those of other known brominated DBPs, such as dibromomethane, which could be generated by decarboxylation of dibromoacetic acid during ionization, dibromophenol, dibromopropanoic acid, dibromobutanoic acid, bromohydroxybenzoic acid, bromophenylacetic acid, bromooxopentenoic acid, and dibromopentenedioic acid. Via comparison to previously described chlorine-containing analogues, bromophenylacetic acid, dibromooxopentenoic acid, and dibromopentenedioic acid were also identified. A novel compound at a 4% relative abundance was identified as tribromoethenesulfonate. This compound has not been previously described as a DBP, and its core structure of tribromoethene has been demonstrated to show toxicological implications. Here we show that electrochemical disinfection, suggested as a candidate for successful ballast water treatment, caused considerable production of some previously characterized DBPs in addition to novel brominated DBPs, although several hundred compounds remain structurally uncharacterized. Our results clearly demonstrate that electrochemical and potentially direct chlorination of ballast water in estuarine and marine systems should be approached with caution and the concentrations, fate, and toxicity of DBP need to be further characterized.

  10. Effect of QMix, peracetic acid and ethylenediaminetetraacetic acid on calcium loss and microhardness of root dentine

    PubMed Central

    Taneja, Sonali; Kumari, Manju; Anand, Surbhi

    2014-01-01

    Objectives: The objective of this in vitro study was to assess the effect of different chelating agents on the calcium loss and its subsequent effect on the microhardness of the root dentin. Materials and Methods: Ten single rooted lower premolars were selected. The teeth were decoronated and thick transverse sections of 2 mm were obtained from the coronal third of the root. Each section was then divided into four quarters, each part constituting a sample specimen from the same tooth for each group. The treatment groups were: Group 1 (Control): 5% Sodium hypochlorite (NaOCl) for 5 min + distilled water for 5 min; Group 2: 5% NaOCl for 5 min + 17% ethylenediaminetetraacetic acid (EDTA) for 5 min; Group 3: 5% NaOCl for 5 min + 2.25% Peracetic acid (PAA) for 5 min and Group 4: 5% NaOCl for 5 min + QMix for 5 min respectively. The calcium loss of the samples was evaluated using the Atomic Absorption Spectrophotometer followed by determination of their microhardness using Vickers Hardness Tester. Data was analyzed using one-way ANOVA, Post hoc Tukey test and Pearson correlation. Results: The maximum calcium loss and minimum microhardness was observed in Group 3 followed by Group 2, Group 4 and Group 1. There was a statistically significant difference between all the groups except between Groups 2 and 4. Conclusions: Irrigation with NaOCl + 2.25% PAA caused the maximum calcium loss from root dentin and reduced microhardness. A negative correlation existed between the calcium loss and reduction in the microhardness of root dentin. PMID:24778513

  11. A novel approach in acidic disinfection through inhibition of acid resistance mechanisms; Maleic acid-mediated inhibition of glutamate decarboxylase activity enhances acid sensitivity of Listeria monocytogenes.

    PubMed

    Paudyal, Ranju; Barnes, Ruth H; Karatzas, Kimon Andreas G

    2018-02-01

    Here it is demonstrated a novel approach in disinfection regimes where specific molecular acid resistance systems are inhibited aiming to eliminate microorganisms under acidic conditions. Despite the importance of the Glutamate Decarboxylase (GAD) system for survival of Listeria monocytogenes and other pathogens under acidic conditions, its potential inhibition by specific compounds that could lead to its elimination from foods or food preparation premises has not been studied. The effects of maleic acid on the acid resistance of L. monocytogenes were investigated and found that it has a higher antimicrobial activity under acidic conditions than other organic acids, while this could not be explained by its pKa or Ka values. The effects were found to be more pronounced on strains with higher GAD activity. Maleic acid affected the extracellular GABA levels while it did not affect the intracellular ones. Maleic acid had a major impact mainly on GadD2 activity as also shown in cell lysates. Furthermore, it was demonstrated that maleic acid is able to partly remove biofilms of L. monocytogenes. Maleic acid is able to inhibit the GAD of L. monocytogenes significantly enhancing its sensitivity to acidic conditions and together with its ability to remove biofilms, make a good candidate for disinfection regimes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Disinfecting capabilities of oxychlorine compounds.

    PubMed Central

    Noss, C I; Olivieri, V P

    1985-01-01

    The bacterial virus f2 was inactivated by chlorine dioxide at acidic, neutral, and alkaline pH values. The rate of inactivation increased with increasing pH. Chlorine dioxide disproportionation products, chlorite and chlorate, were not active disinfectants. As chlorine dioxide solutions were degraded under alkaline conditions, they displayed reduced viricidal effectiveness, thereby confirming the chlorine dioxide free radical as the active disinfecting species. PMID:3911893

  13. Alterations in ovarian follicular progesterone secretion by elevated exposures to the drinking water disinfection by-product dibromoacetic acid: examination of the potential site(s) of impact along the steroidogenic pathway

    EPA Science Inventory

    Previous data from our laboratory indicated that the drinking water disinfection by-product, dibromoacetic acid (DBA), when applied in vitro to rat preovulatory follicles at a concentration consistent with blood levels found to disrupt estrous cyclicity, was able to block the sti...

  14. Decontamination of materials contaminated with Bacillus anthracis and Bacillus thuringiensis Al Hakam spores using PES-Solid, a solid source of peracetic acid.

    PubMed

    Buhr, T L; Wells, C M; Young, A A; Minter, Z A; Johnson, C A; Payne, A N; McPherson, D C

    2013-08-01

    To develop test methods and evaluate survival of Bacillus anthracis Ames, B. anthracis ∆Sterne and B. thuringiensis Al Hakam spores after exposure to PES-Solid (a solid source of peracetic acid), including PES-Solid formulations with bacteriostatic surfactants. Spores (≥ 7 logs) were dried on seven different test materials and treated with three different PES-Solid formulations (or preneutralized controls) at room temperature for 15 min. There was either no spore survival or less than 1 log (<10 spores) of spore survival in 56 of 63 test combinations (strain, formulation and substrate). Less than 2.7 logs (<180 spores) survived in the remaining seven test combinations. The highest spore survival rates were seen on water-dispersible chemical agent resistant coating (CARC-W) and Naval ship topcoat (NTC). Electron microscopy and Coulter analysis showed that all spore structures were intact after spore inactivation with PES-Solid. Three PES-Solid formulations inactivated Bacillus spores that were dried on seven different materials. A test method was developed to show that PES-Solid formulations effectively inactivate Bacillus spores on different materials. Published 2013. This article is a U.S. Government work and is in the public domain in the USA.

  15. Cytotoxicity of peracetic acid: evaluation of effects on metabolism, structure and cell death.

    PubMed

    Viola, K S; Rodrigues, E M; Tanomaru-Filho, M; Carlos, I Z; Ramos, S G; Guerreiro-Tanomaru, J M; Faria, G

    2017-01-30

    To evaluate the cytotoxicity and the mechanism of cell aggression of peracetic acid (PA) in comparison with sodium hypochlorite (NaOCl). L929 fibroblasts were exposed to 1% PA and 2.5% NaOCl, at several dilutions for 10 min. The following parameters were evaluated: cell metabolism by methylthiazol tetrazolium assay, external morphology by scanning electron microscopy, ultrastructure by transmission electron microscopy, the cytoskeleton by means of actin and α-tubulin labelling, and the type of cell death by flow cytometry (apoptosis/necrosis). The data were analysed by two-way anova and the Bonferroni post-test (α = 0.05). The PA group had lower cell viability and a higher percentage of necrotic cells than the NaOCl group (P < 0.05). Both solutions diminished cell metabolism, led to destructuring of the cytoskeleton, created changes in the external morphology, resulted in the accumulation of proteins in the rough endoplasmic reticulum and induced cell death predominantly by necrosis. However, these changes were observed in lower doses of PA when compared with NaOCl. Although they had the same mechanism of cytotoxicity, 1% PA had greater cytotoxic potential than 2.5% NaOCl. © 2017 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  16. Effect of peracetic acid on biofilms formed by Staphylococcus aureus and Listeria monocytogenes isolated from dairy plants.

    PubMed

    Lee, S H I; Cappato, L P; Corassin, C H; Cruz, A G; Oliveira, C A F

    2016-03-01

    This research investigated the removal of adherent cells of 4 strains of Staphylococcus aureus and 1 Listeria monocytogenes strain (previously isolated from dairy plants) from polystyrene microtiter plates using peracetic acid (PAA, 0.5%) for 15, 30, 60, and 120 s, and the inactivation of biofilms formed by those strains on stainless steel coupons using the same treatment times. In the microtiter plates, PAA removed all S. aureus at 15 s compared with control (no PAA treatment). However, L. monocytogenes biofilm was not affected by any PAA treatment. On the stainless steel surface, epifluorescence microscopy using LIVE/DEAD staining (BacLight, Molecular Probes/Thermo Fisher Scientific, Eugene, OR) showed that all strains were damaged within 15 s, with almost 100% of cells inactivated after 30 s. Results of this trial indicate that, although PAA was able to inactivate both S. aureus and L. monocytogenes monospecies biofilms on stainless steel, it was only able to remove adherent cells of S. aureus from polystyrene microplates. The correct use of PAA is critical for eliminating biofilms formed by S. aureus strains found in dairy plants, although further studies are necessary to determine the optimal PAA treatment for removing biofilms of L. monocytogenes. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  17. Peracetic Acid: A Practical Agent for Sterilizing Heat-Labile Polymeric Tissue-Engineering Scaffolds

    PubMed Central

    Yoganarasimha, Suyog; Trahan, William R.; Best, Al M.; Bowlin, Gary L.; Kitten, Todd O.; Moon, Peter C.

    2014-01-01

    Advanced biomaterials and sophisticated processing technologies aim at fabricating tissue-engineering scaffolds that can predictably interact within a biological environment at the cellular level. Sterilization of such scaffolds is at the core of patient safety and is an important regulatory issue that needs to be addressed before clinical translation. In addition, it is crucial that meticulously engineered micro- and nano- structures are preserved after sterilization. Conventional sterilization methods involving heat, steam, and radiation are not compatible with engineered polymeric systems because of scaffold degradation and loss of architecture. Using electrospun scaffolds made from polycaprolactone, a low melting polymer, and employing spores of Bacillus atrophaeus as biological indicators, we compared ethylene oxide, autoclaving and 80% ethanol to a known chemical sterilant, peracetic acid (PAA), for their ability to sterilize as well as their effects on scaffold properties. PAA diluted in 20% ethanol to 1000 ppm or above sterilized electrospun scaffolds in 15 min at room temperature while maintaining nano-architecture and mechanical properties. Scaffolds treated with PAA at 5000 ppm were rendered hydrophilic, with contact angles reduced to 0°. Therefore, PAA can provide economical, rapid, and effective sterilization of heat-sensitive polymeric electrospun scaffolds that are used in tissue engineering. PMID:24341350

  18. Decontamination of a drinking water pipeline system contaminated with adenovirus and Escherichia coli utilizing peracetic acid and chlorine.

    PubMed

    Kauppinen, Ari; Ikonen, Jenni; Pursiainen, Anna; Pitkänen, Tarja; Miettinen, Ilkka T

    2012-09-01

    A contaminated drinking water distribution network can be responsible for major outbreaks of infections. In this study, two chemical decontaminants, peracetic acid (PAA) and chlorine, were used to test how a laboratory-scale pipeline system can be cleaned after simultaneous contamination with human adenovirus 40 (AdV40) and Escherichia coli. In addition, the effect of the decontaminants on biofilms was followed as heterotrophic plate counts (HPC) and total cell counts (TCC). Real-time quantitative polymerase chain reaction (qPCR) was used to determine AdV40 and plate counting was used to enumerate E. coli. PAA and chlorine proved to be effective decontaminants since they decreased the levels of AdV40 and E. coli to below method detection limits in both water and biofilms. However, without decontamination, AdV40 remained present in the pipelines for up to 4 days. In contrast, the concentration of cultivable E. coli decreased rapidly in the control pipelines, implying that E. coli may be an inadequate indicator for the presence of viral pathogens. Biofilms responded to the decontaminants by decreased HPCs while TCC remained stable. This indicates that the mechanism of pipeline decontamination by chlorine and PAA is inactivation rather than physical removal of microbes.

  19. Toxicity of peracetic acid (PAA) to tomonts of IIchthyophthirius multifiliis.

    PubMed

    Meinelt, T; Matzke, S; Stübert, A; Pietrock, M; Wienke, A; Mitchell, A J; Strauss, D L

    2009-09-07

    The free-living infective theront of Ichthyophthirius multifiliis historically has been thought to be the only stage susceptible to treatment. Here we introduce a technique to determine the toxicity of compounds to the newly released tomont, the encysted tomont and the developing tomites within the tomont that emerge as theronts. The toxicity of Wofasteril E400 (40% peracetic acid, PAA) to free-living forms of I. multifiliis was determined shortly after tomonts were physically removed from the surface of the fish and at 2.5 and 24 h after removal. Results indicate that 0.6 to 0.9 mg l(-1) PAA killed 39 to 82% of the newly released tomonts within 48 h when treated immediately. In a second experiment, tomonts were allowed to settle for 2.5 h after sampling from the skin and then treated for 12 h; concentrations > or =0.5 mg l(-1) PAA produced significantly fewer theronts than the controls. In a third experiment, encysted tomonts that were exposed to PAA 24 h after sampling from the skin and treated for 2 or 4 h produced a variable amount of theronts, but the concentrations tested (0.5 to 3.0 mg l(-1)) did not halt theront production. This research demonstrates that encysted I. multifiliis are less susceptible to chemical treatments.

  20. Evaluation of continuous 4-day exposure to peracetic acid as a treatment for Ichthyophthirius multifiliis.

    PubMed

    Sudová, Eliska; Straus, David L; Wienke, Andreas; Meinelt, Thomas

    2010-01-01

    The parasitic ciliate Ichthyophthirius multifiliis infests all species of freshwater fish and can cause severe economic losses in fish breeding. The most effective treatment, malachite green, has been banned in Europe and North America for use in food fish production. Peracetic acid (PAA) was found to be toxic to I. multifiliis theronts at low concentrations. I. multifiliis-infested carp were exposed to 1 mg/l PAA in a dynamic exposure by means of peristaltic pumps. Five days after infestation, gills, tail fins, and skin below the dorsal fin were observed microscopically for I. multifiliis abundance. After PAA exposure, PAA-treated fish showed lower infestation of I. multifiliis in all investigated tissues than the unexposed control fish. The infestation increased in the control group whereas the infestation in the PAA-exposed groups significantly decreased (p = 0.0083, Bonferroni correction). The fish in the two exposure groups showed a slight reinfestation with I. multifiliis. This might be caused by a peroxide degradation (hydrolysis) and/or reduction of the delivered PAA concentration. Thus, PAA concentrations were possibly too low to be effective on the released trophonts and/or the infective theronts. This hypothesis is corroborated by the fact that the I. multifiliis in the gills, skin, and fins of the PAA-exposed carp were in an early developmental stage.

  1. Antimicrobial activity of Chlorhexidine, Peracetic acid and Sodium hypochlorite/etidronate irrigant solutions against Enterococcus faecalis biofilms.

    PubMed

    Arias-Moliz, M T; Ordinola-Zapata, R; Baca, P; Ruiz-Linares, M; García García, E; Hungaro Duarte, M A; Monteiro Bramante, C; Ferrer-Luque, C M

    2015-12-01

    To evaluate the antimicrobial effect of 2.5% sodium hypochlorite alone (NaOCl) and associated with 9% HEBP (NaOCl/HEBP), 2% peracetic acid (PAA) and 2% chlorhexidine (CHX), on the viability of Enterococcus faecalis biofilms attached to dentine. Biofilms of E. faecalis were grown on the surface of dentine blocks for 5 days and then exposed to the irrigating solutions for 3 min. Distilled water was used as the control. The total biovolume and the percentage of dead cells of the infected dentine were measured by means of confocal microscopy and the live/dead technique. Nonparametric tests were used to determine statistical differences (P < 0.05). NaOCl and the NaOCl/HEBP mixture were associated with a significantly greater percentage of dead cells, followed by PAA (P < 0.05). No significant antimicrobial effect of CHX was observed in comparison with the control group. Total biovolume decreased significantly in NaOCl, NaOCl/HEBP and PAA solutions in comparison with the CHX and control groups. NaOCl alone or associated with HEBP were the most effective irrigant solutions in dissolving and killing E. faecalis biofilms. © 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  2. Degradation of Amino Acids and Structure in Model Proteins and Bacteriophage MS2 by Chlorine, Bromine, and Ozone.

    PubMed

    Choe, Jong Kwon; Richards, David H; Wilson, Corey J; Mitch, William A

    2015-11-17

    Proteins are important targets of chemical disinfectants. To improve the understanding of disinfectant-protein reactions, this study characterized the disinfectant:protein molar ratios at which 50% degradation of oxidizable amino acids (i.e., Met, Tyr, Trp, His, Lys) and structure were observed during HOCl, HOBr, and O3 treatment of three well-characterized model proteins and bacteriophage MS2. A critical question is the extent to which the targeting of amino acids is driven by their disinfectant rate constants rather than their geometrical arrangement. Across the model proteins and bacteriophage MS2 (coat protein), differing widely in structure, methionine was preferentially targeted, forming predominantly methionine sulfoxide. This targeting concurs with its high disinfectant rate constants and supports its hypothesized role as a sacrificial antioxidant. Despite higher HOCl and HOBr rate constants with histidine and lysine than for tyrosine, tyrosine generally was degraded in preference to histidine, and to a lesser extent, lysine. These results concur with the prevalence of geometrical motifs featuring histidines or lysines near tyrosines, facilitating histidine and lysine regeneration upon Cl[+1] transfer from their chloramines to tyrosines. Lysine nitrile formation occurred at or above oxidant doses where 3,5-dihalotyrosine products began to degrade. For O3, which lacks a similar oxidant transfer pathway, histidine, tyrosine, and lysine degradation followed their relative O3 rate constants. Except for its low reactivity with lysine, the O3 doses required to degrade amino acids were as low as or lower than for HOCl or HOBr, indicating its oxidative efficiency. Loss of structure did not correlate with loss of particular amino acids, suggesting the need to characterize the oxidation of specific geometric motifs to understand structural degradation.

  3. Effect of Exposure Time and Organic Matter on Efficacy of Antimicrobial Compounds against Shiga Toxin-Producing Escherichia coli and Salmonella.

    PubMed

    Kalchayanand, Norasak; Koohmaraie, Mohammad; Wheeler, Tommy L

    2016-04-01

    Several antimicrobial compounds are in commercial meat processing plants for pathogen control on beef carcasses. However, the efficacy of the method used is influenced by a number of factors, such as spray pressure, temperature, type of chemical and concentration, exposure time, method of application, equipment design, and the stage in the process that the method is applied. The objective of this study was to evaluate effectiveness of time of exposure of various antimicrobial compounds against nine strains of Shiga toxin-producing Escherichia coli (STEC) and four strains of Salmonella in aqueous antimicrobial solutions with and without organic matter. Non-O157 STEC, STEC O157:H7, and Salmonella were exposed to the following aqueous antimicrobial solutions with or without beef purge for 15, 30, 60, 120, 300, 600, and 1,800 s: (i) 2.5% lactic acid, (ii) 4.0% lactic acid, (iii) 2.5% Beefxide, (iv) 1% Aftec 3000, (v) 200 ppm of peracetic acid, (vi) 300 ppm of hypobromous acid, and (vii) water as a control. In general, increasing exposure time to antimicrobial compounds significantly (P ≤ 0.05) increased the effectiveness against pathogens tested. In aqueous antimicrobial solutions without organic matter, both peracetic acid and hypobromous acid were the most effective in inactivating populations of STEC and Salmonella, providing at least 5.0-log reductions with exposure for 15 s. However, in antimicrobials containing organic matter, 4.0% lactic acid was the most effective compound in reducing levels of STEC and Salmonella, providing 2- to 3-log reductions with exposure for 15 s. The results of this study indicated that organic matter and exposure time influenced the efficacy of antimicrobial compounds against pathogens, especially with oxidizer compounds. These factors should be considered when choosing an antimicrobial compound for an intervention.

  4. Evaluation of cytotoxicity, genotoxicity, and apoptosis of wastewater before and after disinfection with performic acid.

    PubMed

    Ragazzo, Patrizia; Feretti, Donatella; Monarca, Silvano; Dominici, Luca; Ceretti, Elisabetta; Viola, Gaia; Piccolo, Valentina; Chiucchini, Nicoletta; Villarini, Milena

    2017-06-01

    Disinfection with performic acid (PFA) represents an emerging technology in wastewater treatment. Many recent studies indicate its effectiveness and suitability as a disinfectant for different applications; several have demonstrated its reliability as an alternative to chlorine for disinfecting secondary effluents from urban wastewater treatment plants (WWTPs). Some disinfection technologies, in relation to their oxidative power, lead to the formation of disinfection by-products (DBPs), some of which are of concern for their toxic and carcinogenic potential. The aim of this study was to investigate potential genotoxic, cytotoxic, and mutagenic effects of this disinfection agent on treated secondary effluent coming from a municipal WWTP. A strategy with multiple short-term tests and different target cells (bacterial, plant, and mammalian) was adopted to explore a relatively wide range of potential genotoxic events. The Ames test (point mutation in Salmonella), the micronucleus (chromosomal damage) and Comet tests (primary DNA damage) on human hepatic cells (HepG2) were conducted to detect mutagenicity and chromosomal DNA alterations. DNA fragmentation and mitochondrial potential assays were conducted to evaluate apoptosis in the same kinds of cells. Mutagenic and clastogenic effect potentials were evaluated by examining micronucleus formation in Allium cepa root cells. In all the in vitro tests, carried out on both disinfected and non-disinfected effluents, negative results were always obtained for mutagenic and genotoxic effects. In the Allium cepa tests, however, some non-concentrated wastewater samples after PFA treatment induced a slight increase in micronucleus frequencies in root cells, but not in a dose-related manner. In conclusion, PFA applied for disinfection to a secondary effluent from a municipal wastewater treatment plant did not contribute to the release of genotoxic or mutagenic compounds. Further studies are required to establish to which extent these findings can be generalized to support PFA for other disinfection applications. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Cryptosporidium-contaminated water disinfection by a novel Fenton process.

    PubMed

    Matavos-Aramyan, Sina; Moussavi, Mohsen; Matavos-Aramyan, Hedieh; Roozkhosh, Sara

    2017-05-01

    Three novel modified advanced oxidation process systems including ascorbic acid-, pro-oxidants- and ascorbic acid-pro-oxidants-modified Fenton system were utilized to study the disinfection efficiency on Cryptosporidium-contaminated drinking water samples. Different concentrations of divalent and trivalent iron ions, hydrogen peroxide, ascorbic acid and pro-oxidants at different exposure times were investigated. These novel systems were also compared to the classic Fenton system and to the control system which comprised of only hydrogen peroxide. The complete in vitro mechanism of the mentioned modified Fenton systems are also provided. The results pointed out that by considering the optimal parameter limitations, the ascorbic acid-modified Fenton system decreased the Cryptosporidium oocytes viability to 3.91%, while the pro-oxidant-modified and ascorbic acid-pro-oxidant-modified Fenton system achieved an oocytes viability equal to 1.66% and 0%, respectively. The efficiency of the classic Fenton at optimal condition was observed to be 20.12% of oocytes viability. The control system achieved 86.14% of oocytes viability. The optimum values of the operational parameters during this study are found to be 80mgL -1 for the divalent iron, 30mgL -1 for ascorbic acid, 30mmol for hydrogen peroxide, 25mgL -1 for pro-oxidants and an exposure time equal to 5min. The ascorbic acid-pro-oxidants-modified Fenton system achieved a promising complete water disinfection (0% viability) at the optimal conditions, leaving this method a feasible process for water disinfection or decontamination, even at industrial scales. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Free Available Chlorine Disinfection Criteria for Fixed Army Installation Primary Drinking Water

    DTIC Science & Technology

    1981-12-01

    Buffered Water with Fuivic Acid (5 C.U.) at pH 9 and 60C ............................................ 6. FAC Disinfection of f 2 Coliphage in Buffered Water ...with and without 250 mg/L -Ca+ at pH 5, 7, and 9 and 6°C ............... 31 10. FAC Disinfection of f 2 Coliphage in Water Containing 5 NTU Bentonite2...rngi L Ca+ 2 at pH- 5, 7, and q and 60C ...... ........................ 34 13. FAC Disinfection of f 2 Coliphage in Borate-Buffered Water with 250 mg

  7. The Influence of Interfering Substances on the Antimicrobial Activity of Selected Quaternary Ammonium Compounds

    PubMed Central

    Araújo, Paula A.; Lemos, Madalena; Mergulhão, Filipe; Melo, Luís; Simões, Manuel

    2013-01-01

    Standard cleaning processes may not remove all the soiling typically found in food industry, such as carbohydrates, fats, or proteins. Contaminants have a high impact in disinfection as their presence may reduce the activity of disinfectants. The influence of alginic acid, bovine serum albumin, yeast extract, and humic acids was assessed on the antimicrobial activities of benzalkonium chloride and cetyltrimethyl ammonium bromide against Bacillus cereus vegetative cells and Pseudomonas fluorescens. The bacteria (single and consortium) were exposed to surfactants (single and combined) in the absence and presence of potential disinfection interfering substances. The antimicrobial effects of the surfactants were assessed based on the bacterial respiratory activity measured by oxygen uptake rate due to glucose oxidation. The tested surfactants were efficient against both bacteria (single and consortium) with minimum bactericidal concentrations ranging from 3 to 35 mg·L−1. The strongest effect was caused by humic acids that severely quenched antimicrobial action, increasing the minimum bactericidal concentration of the surfactants on P. fluorescens and the consortium. The inclusion of the other interfering substances resulted in mild interferences in the antibacterial activity. This study clearly demonstrates that humic acids should be considered as an antimicrobial interfering substance in the development of disinfection strategies. PMID:26904590

  8. Bactericidal Efficacy of Hydrogen Peroxide-Based Disinfectants Against Gram-Positive and Gram-Negative Bacteria on Stainless Steel Surfaces.

    PubMed

    Ríos-Castillo, Abel G; González-Rivas, Fabián; Rodríguez-Jerez, José J

    2017-10-01

    In order to develop disinfectant formulations that leverage the effectiveness of hydrogen peroxide (H 2 O 2 ), this study evaluated the bactericidal efficacy of hydrogen peroxide-based disinfectants against Gram-positive and Gram-negative bacteria on stainless steel surfaces. Low concentration of hydrogen peroxide as 0.5% with a cationic polymer, ethoxylated fatty alcohol, and ethyl alcohol had bactericidal efficacy (reductions ≥ 4 log 10 CFU/mL) against Escherichia coli, Staphylococcus aureus, Enterococcus hirae, and Pseudomonas aeruginosa. Hydrogen peroxide-based disinfectants were more effective against E. hirae and P. aeruginosa than to S. aureus. However, the efficacy of hydrogen peroxide against catalase positive bacteria such as S. aureus was increased when this compound was formulated with low concentrations of benzalkonium chloride or ethyl alcohol, lactic acid, sodium benzoate, cationic polymer, and salicylic acid. This study demonstrates that the use of hydrogen peroxide with other antimicrobial products, in adequate concentrations, had bactericidal efficacy in Gram-positive and Gram-negative bacteria on stainless steel surfaces, enabling to reduce the effective concentration of hydrogen peroxide. In the same way, the use of hydrogen peroxide-based disinfectants could reduce the concentrations of traditional disinfectants as quaternary ammonium compounds and therefore a reduction of their chemical residues in the environment after being used. The study of the bactericidal properties of environmentally nontoxic disinfectants such as hydrogen peroxide, sole or in formulations with other disinfectants against Gram-positive and Gram-negative bacteria can enhance the efficacy of various commonly used disinfectant formulations with the hygiene benefits that it entails. Also, the use of hydrogen peroxide formulations can reduce the concentration levels of products that generate environmental residues. © 2017 Institute of Food Technologists®.

  9. Effect of Electrolyzed Water on the Disinfection of Bacillus cereus Biofilms: The Mechanism of Enhanced Resistance of Sessile Cells in the Biofilm Matrix.

    PubMed

    Hussain, Mohammad Shakhawat; Kwon, Minyeong; Tango, Charles Nkufi; Oh, Deog Hwan

    2018-05-01

    This study examined the disinfection efficacy and mechanism of electrolyzed water (EW) on Bacillus cereus biofilms. B. cereus strains, ATCC 14579 and Korean Collection for Type Cultures (KCTC) 13153 biofilms, were formed on stainless steel (SS) and plastic slide (PS) coupons. Mature biofilms were treated with slightly acidic EW (SAEW), acidic EW (AEW), and basic EW (BEW). SAEW (available chlorine concentration, 25 ± 1.31 mg L -1 ; pH 5.71 ± 0.16; and oxidation reduction potential, 818 to 855 mV) reduced ATCC 14579 biofilms on plastic slides to below the detection limit within 30 s. However, biofilms on SS coupons showed a higher resistance to the SAEW treatment. When the disinfection activities of three types of EW on biofilms were compared, AEW showed a higher bactericidal activity, followed by SAEW and BEW. In contrast, BEW showed a significantly ( P < 0.05) higher biofilm dispersal activity than AEW and SAEW. SAEW disinfection of the B. cereus biofilms was due to the disruption of the B. cereus plasma membrane. The higher resistance of biofilms formed on the SS coupon might be due to the higher number of attached cells and extracellular polymeric substances formation that reacts with the active chlorine ions, such as hypochlorous acid and hypochlorite ion of SAEW, which decreased the disinfection efficacy of SAEW. This study showed that the EW treatment effectively disinfected B. cereus biofilms, providing insight into the potential use of EW in the food processing industry to control the biofilm formation of B. cereus.

  10. Emerging Disinfection By-Products and Other Emerging Environmental Contaminants: What’s New

    EPA Science Inventory

    This presentation will cover new research and concerns regarding drinking water disinfection by-products (DBPs) and other emerging environmental contaminants, such as perfluorooctanoic acid (PFOA), pharmaceuticals, perchlorate, benzotriazoles, fuel additives (e.g., ethylene dibro...

  11. Recycled Water Poses Disinfectant Problem

    ERIC Educational Resources Information Center

    Chemical and Engineering News, 1973

    1973-01-01

    Discusses the possible health hazards resulting from released nucleic acid of inactivated viruses, chlorinated nonliving organic molecules, and overestimated reliability of waste treatment standards. Suggests the recycle system use a dual disinfectant such as chlorine and ozone in water treatment. (CC)

  12. Glucuronidation of 6 alpha-hydroxy bile acids by human liver microsomes.

    PubMed Central

    Radomińska-Pyrek, A; Zimniak, P; Irshaid, Y M; Lester, R; Tephly, T R; St Pyrek, J

    1987-01-01

    The glucuronidation of 6-hydroxylated bile acids by human liver microsomes has been studied in vitro; for comparison, several major bile acids lacking a 6-hydroxyl group were also investigated. Glucuronidation rates for 6 alpha-hydroxylated bile acids were 10-20 times higher than those of substrates lacking a hydroxyl group in position 6. The highest rates measured were for hyodeoxy- and hyocholic acids, and kinetic analyses were carried out using these substrates. Rigorous product identification by high-field proton nuclear magnetic resonance and by electron impact mass spectrometry of methyl ester/peracetate derivatives revealed that 6-O-beta-D-glucuronides were the exclusive products formed in these enzymatic reactions. These results, together with literature data, indicate that 6 alpha-hydroxylation followed by 6-O-glucuronidation constitutes an alternative route of excretion of toxic hydrophobic bile acids. PMID:3110212

  13. Biodegradation of disinfection byproducts as a potential removal process during aquifer storage recovery

    USGS Publications Warehouse

    Landmeyer, J.E.; Bradley, P.M.; Thomas, J.M.

    2000-01-01

    The biodegradation potential of two drinking water disinfection byproducts was investigated using aquifer materials obtained from approximately 100 and 200 meters below land surface in an aerobic aquifer system undergoing aquifer storage recovery of treated surface water. No significant biodegradation of a model trihalomethane compound, chloroform, was observed in aquifer microcosms under aerobic or anaerobic conditions. In contrast, between 16 and 27 percent mineralization of a radiolabeled model haloacetic acid compound, chloroacetic acid, was observed. These results indicate that although the potential for biodegradation of chloroacetic acid exists in deep aquifer systems, chloroform entrained within these aquifers or formed in situ will tend to persist. These results have important implications for water managers planning to meet anticipated lowered permissible levels of tri-halomethanes in drinking water.The biodegradation potential of two drinking water disinfection byproducts was investigated using aquifer materials obtained from approximately 100 and 200 meters below land surface in an aerobic aquifer system undergoing aquifer storage recovery of treated surface water. No significant biodegradation of a model trihalomethane compound, chloroform, was observed in aquifer microcosms under aerobic or anaerobic conditions. In contrast, between 16 and 27 percent mineralization of a radiolabeled model haloacetic acid compound, chloroacetic acid, was observed. These results indicate that although the potential for biodegradation of chloroacetic acid exists in deep aquifer systems, chloroform entrained within these aquifers or formed in situ will tend to persist. These results have important implications for water managers planning to meet anticipated lowered permissible levels of trihalomethanes in drinking water.Aquifer-storage-recovery injection water often contains disinfection byproducts. Results are presented from a study in which two model disinfection byproducts, chloroform and chloroacetic acid, were used to examine biodegradation by indigenous microorganisms. The recharge system studied was near Las Vegas, NV, where the aquifers are recharged artificially during the winter months. Microcosms were constructed using aquifer material recovered from two layers. Results showed that no significant biodegradation of chloroform occurred under aerobic or anaerobic conditions, but chloroacetic acid was biodegraded under both aerobic and anaerobic conditions.

  14. The formation and control of emerging disinfection by-products of health concern.

    PubMed

    Krasner, Stuart W

    2009-10-13

    When drinking water treatment plants disinfect water, a wide range of disinfection by-products (DBPs) of health and regulatory concern are formed. Recent studies have identified emerging DBPs (e.g. iodinated trihalomethanes (THMs) and acids, haloacetonitriles, halonitromethanes (HNMs), haloacetaldehydes, nitrosamines) that may be more toxic than some of the regulated ones (e.g. chlorine- and bromine-containing THMs and haloacetic acids). Some of these emerging DBPs are associated with impaired drinking water supplies (e.g. impacted by treated wastewater, algae, iodide). In some cases, alternative primary or secondary disinfectants to chlorine (e.g. chloramines, chlorine dioxide, ozone, ultraviolet) that minimize the formation of some of the regulated DBPs may increase the formation of some of the emerging by-products. However, optimization of the various treatment processes and disinfection scenarios can allow plants to control to varying degrees the formation of regulated and emerging DBPs. For example, pre-disinfection with chlorine, chlorine dioxide or ozone can destroy precursors for N-nitrosodimethylamine, which is a chloramine by-product, whereas pre-oxidation with chlorine or ozone can oxidize iodide to iodate and minimize iodinated DBP formation during post-chloramination. Although pre-ozonation may increase the formation of trihaloacetaldehydes or selected HNMs during post-chlorination or chloramination, biofiltration may reduce the formation potential of these by-products.

  15. Silica Gel for Enhanced Activity and Hypochlorite Protection of Cyanuric Acid Hydrolase in Recombinant Escherichia coli.

    PubMed

    Radian, Adi; Aukema, Kelly G; Aksan, Alptekin; Wackett, Lawrence P

    2015-11-03

    Chlorinated isocyanuric acids are widely used water disinfectants that generate hypochlorite, but with repeated application, they build up cyanuric acid (CYA) that must be removed to maintain disinfection. 3-Aminopropyltriethoxysilane (APTES)-treated Escherichia coli cells expressing cyanuric acid hydrolase (CAH) from Moorella thermoacetica exhibited significantly high CYA degradation rates and provided protection against enzyme inactivation by hypochlorite (chlorine). APTES coating or encapsulation of cells had two benefits: (i) overcoming diffusion limitations imposed by the cell wall and (ii) protecting against hypochlorite inactivation of CAH activity. Cells encapsulated in APTES gels degraded CYA three times faster than nonfunctionalized tetraethoxysilane (TEOS) gels, and cells coated with APTES degraded CYA at a rate of 29 µmol/min per mg of CAH protein, similar to the rate with purified enzyme. UV spectroscopy, fluorescence spectroscopy, and scanning electron microscopy showed that the higher rates were due to APTES increasing membrane permeability and enhancing cyanuric acid diffusion into the cytoplasm to reach the CAH enzyme. Purified CAH enzyme was shown to be rapidly inactivated by hypochlorite. APTES aggregates surrounding cells protected via the amine groups reacting with hypochlorite as shown by pH changes, zeta potential measurements, and infrared spectroscopy. APTES-encapsulated E. coli cells expressing CAH degraded cyanuric acid at high rates in the presence of 1 to 10 ppm hypochlorite, showing effectiveness under swimming pool conditions. In contrast, CAH activity in TEOS gels or free cells was completely inactivated by hypochlorite. These studies show that commercially available silica materials can selectively enhance, protect, and immobilize whole-cell biocatalysts for specialized applications. Hypochlorite is used in vast quantities for water disinfection, killing bacteria on surfaces, and washing and whitening. In pools, spas, and other waters, hypochlorite is frequently delivered as chlorinated isocyanuric acids that release hypochlorite and cyanuric acid. Over time, cyanuric acid accumulates and impairs disinfection and must be removed. The microbial enzyme cyanuric acid hydrolase can potentially remove cyanuric acid to restore disinfection and protect swimmers. Whole bacterial cells expressing cyanuric acid hydrolase were encapsulated in an inert silica matrix containing an amine group. The amine group serves to permeabilize the cell membrane and accelerate cyanuric acid degradation, and it also reacts with hypochlorite to protect against inactivation of cyanuric acid hydrolase. Methods for promoting whole-cell biocatalysis are important in biotechnology, and the present work illustrates approaches to enhance rates and protect against an inhibitory substance. Copyright © 2015 Radian et al.

  16. BACTERIALLY-MEDIATED DEGRADATION OF A CHIRAL DISINFECTION BYPRODUCT

    EPA Science Inventory

    Disinfection of drinking and waste waters, through chlorination, can result in the production of chlorinated organic compounds, many of which are regulated by the U.S. Environmental Protection Agency. Among these regulated compounds are the haloacetic acids, which exhibit toxic e...

  17. HALOACETONITRILES VS. REGULATED HALOACETIC ACIDS: ARE NITROGEN CONTAINING DBPS MORE TOXIC?

    EPA Science Inventory

    Haloacetonitriles (HANs) are toxic nitrogenous drinking water disinfection by-products (N-DBPs) and are observed with chlorine, chloramine, or chlorine dioxide disinfection. Using microplate-based Chinese hamster ovary (CHO) cell assays for chronic cytotoxicity and acute genotoxi...

  18. Formation of disinfection byproducts in typical Chinese drinking water.

    PubMed

    Liu, Wenbo; Zhao, Yanmei; Chow, Christopher W K; Wang, Dongsheng

    2011-01-01

    Eight typical drinking water supplies in China were selected in this study. Both source and tap water were used to investigate the occurrence of chlorinated disinfection byproducts (DBPs), and seasonal variation in the concentrations of trihalomethanes (THMs) of seven water sources was compared. The results showed that the pollution level for source water in China, as shown by DBP formation potential, was low. The most encountered DBPs were chloroform, dichloroacetic acid, trichloroacetic acid, and chlorodibromoacetic acid. The concentration of every THMs and haloacetic acid (HAA) compound was under the limit of standards for drinking water quality. The highest total THMs concentrations were detected in spring.

  19. Use of biological assay systems to assess the relative carcinogenic hazards of disinfection by-products.

    PubMed Central

    Bull, R J; Robinson, M; Meier, J R; Stober, J

    1982-01-01

    Other workers have clearly shown that most, if not all, drinking water in the U.S. contains chemicals that possess mutagenic and/or carcinogenic activity by using bacterial and in vitro methods. In the present work, increased numbers of tumors were observed with samples of organic material isolated from 5 U.S. cities administered as tumor initiators in mouse skin initiation/promotion studies. Only in one case was the result significantly different from control. In studies designed to test whether disinfection practice contributes significantly to the tumor initiating activity found in drinking water mixed results have been obtained. In one experiment, water disinfected by chlorination, ozonation or combined chlorine resulted in a significantly greater number of papillomas when compared to nondisinfected water. In two subsequent experiments, where water was obtained from the Ohio River at different times of the year, no evidence of increased initiating activity was observed with any disinfectant. Analysis of water obtained at the comparable times of the year for total organic halogen, and trihalomethane formation revealed a substantial variation in the formation of these products. Considering the problems such variability poses for estimating risks associated with disinfection by-products, a model system which makes use of commercially obtained humic acid as a substrate for chlorination was investigated using the Ames test. Humic and fulvic acids obtained from two surface waters as well as the commercially obtained humic acid were without activity in TA 1535, TA 1537, TA 1538, TA 98 or TA 100 strains of S. typhimurium. Following treatment with a 0.8 molar ratio of chlorine (based on carbon) significant mutagenic activity was observed with all humic and fulvic acid samples. Comparisons of the specific mutagenic activity of the chlorinated products suggests that the commercial material might provide a useful model for studying health hazards associated with disinfection reactions by-products. PMID:7151763

  20. Mechanism of Bacillus subtilis Spore Inactivation by and Resistance to Supercritical CO2 plus Peracetic Acid

    PubMed Central

    Setlow, Barbara; Korza, George; Blatt, Kelly M.S.; Fey, Julien P.; Setlow, Peter

    2015-01-01

    Aims Determine how supercritical CO2 (scCO2) plus peracetic acid (PAA) inactivates Bacillus subtilis spores, factors important in spore resistance to scCO2-PAA, and if spores inactivated by scCO2-PAA are truly dead. Methods and Results Spores of wild-type B. subtilis and isogenic mutants lacking spore protective proteins were treated with scCO2-PAA in liquid or dry at 35°C. Wild-type wet spores (aqueous suspension) were more susceptible than dry spores. Treated spores were examined for viability (and were truly dead), dipicolinic acid (DPA), mutations, permeability to nucleic acid stains, germination under different conditions, energy metabolism and outgrowth. ScCO2-PAA-inactivated spores retained DPA, and survivors had no notable DNA damage. However, DPA was released from inactivated spores at a normally innocuous temperature (85°C), and colony formation from treated spores was salt sensitive. The inactivated spores germinated but did not outgrow, and these germinated spores had altered plasma membrane permeability and defective energy metabolism. Wet or dry coat-defective spores had increased scCO2-PAA sensitivity, and dry spores but not wet spores lacking DNA protective proteins were more scCO2-PAA sensitive. Conclusions These findings suggest that scCO2-PAA inactivates spores by damaging spores’ inner membrane. The spore coat provided scCO2-PAA resistance for both wet and dry spores. DNA protective proteins provided scCO2-PAA resistance only for dry spores. Significance and Impact of Study These results provide information on mechanisms of spore inactivation of and resistance to scCO2-PAA, an agent with increasing use in sterilization applications. PMID:26535794

  1. Mechanism of Bacillus subtilis spore inactivation by and resistance to supercritical CO2 plus peracetic acid.

    PubMed

    Setlow, B; Korza, G; Blatt, K M S; Fey, J P; Setlow, P

    2016-01-01

    Determine how supercritical CO2 (scCO2 ) plus peracetic acid (PAA) inactivates Bacillus subtilis spores, factors important in spore resistance to scCO2 -PAA, and if spores inactivated by scCO2 -PAA are truly dead. Spores of wild-type B. subtilis and isogenic mutants lacking spore protective proteins were treated with scCO2 -PAA in liquid or dry at 35°C. Wild-type wet spores (aqueous suspension) were more susceptible than dry spores. Treated spores were examined for viability (and were truly dead), dipicolinic acid (DPA), mutations, permeability to nucleic acid stains, germination under different conditions, energy metabolism and outgrowth. ScCO2 -PAA-inactivated spores retained DPA, and survivors had no notable DNA damage. However, DPA was released from inactivated spores at a normally innocuous temperature (85°C), and colony formation from treated spores was salt sensitive. The inactivated spores germinated but did not outgrow, and these germinated spores had altered plasma membrane permeability and defective energy metabolism. Wet or dry coat-defective spores had increased scCO2 -PAA sensitivity, and dry spores but not wet spores lacking DNA protective proteins were more scCO2 -PAA sensitive. These findings suggest that scCO2 -PAA inactivates spores by damaging spores' inner membrane. The spore coat provided scCO2 -PAA resistance for both wet and dry spores. DNA protective proteins provided scCO2 -PAA resistance only for dry spores. These results provide information on mechanisms of spore inactivation of and resistance to scCO2 -PAA, an agent with increasing use in sterilization applications. © 2015 The Society for Applied Microbiology.

  2. Biological Treatment of Water Disinfection Byproducts using Biotrickling Filter under Anaerobic Conditions

    EPA Science Inventory

    Presentation not available. Abstract provided. The chlorination of potable water leads to the formation of harmful disinfection byproducts (DBPs) such as trihalomethanes (THMs) and haloacetic acids (HAAs). Many of these compounds are volatile organic compounds (VOCs). DBPs may ...

  3. HUMAN EXPOSURE TO WATER DISINFECTION BY-PRODUCTS VIA FOODS AND BEVERAGES

    EPA Science Inventory

    The ingestion of tap water is a major route of exposure to water disinfection byproducts (DBPs), including haloacetonitriles, haloketones, and haloacetic acids. A potentially significant alternate route of exposure is through the consumption of beverages prepared with tap water ...

  4. DRINKING WATER DISINFECTION BYPRODUCTS AND DURATION OF GESTATION

    EPA Science Inventory

    Recent studies of drinking water disinfection by-products (DBPs) suggest high exposure decreases risk of preterm birth. We examined this association with total trihalomethane (TTHM) and five haloacetic acids (HAA5) among 2,041 women in a prospective pregnancy study conducted from...

  5. Modification to the AOAC Sporicidal Activity of Disinfectants Test (Method 966.04): collaborative study.

    PubMed

    Tomasino, Stephen F; Hamilton, Martin A

    2006-01-01

    In an effort to improve AOAC Method 966.04, the Sporicidal Activity of Disinfectants Test, selected modifications to the procedure were evaluated in a collaborative study. Method 966.04 is used to generate efficacy data to support the product registration of sporicides and sterilants. The method is a carrier-based test that provides a qualitative measure of product efficacy against spores of Bacillus subtilis and Clostridium sporogenes. The use of garden soil extract and the lack of standard procedures for the enumeration of spores and neutralization of the test chemicals have been considered problematic for many years. The proposed modifications were limited to the B. subtilis and hard surface carrier (porcelain penicylinder) components of the method. The study included the evaluation of a replacement for soil extract nutrient broth and an establishment of a minimum spore titer per carrier, both considered crucial for the improvement and utilization of the method. Additionally, an alternative hard surface material and a neutralization confirmation procedure were evaluated. To determine the equivalence of the proposed alternatives to the standard method, 3 medium/carrier combinations, (1) soil extract nutrient broth/porcelain carrier (current method), (2) nutrient agar amended with 5 microg/mL manganese sulfate/porcelain carrier, and (3) nutrient agar amended with 5 microg/mL manganese sulfate/stainless steel carrier were analyzed for carrier counts, HCI resistance, efficacy, quantitative efficacy, and spore wash-off. The test chemicals used in the study represent 3 chemical classes and are commercially available antimicrobial liquid products: sodium hypochlorite (bleach), glutaraldehyde, and a combination of peracetic acid and hydrogen peroxide. Four laboratories participated in the study. The results of the spore titer per carrier, HCI resistance, efficacy, and wash-off studies demonstrate that amended nutrient agar in conjunction with the porcelain is comparable to the current method, soil extract nutrient broth/porcelain. The nutrient agar method is simple, inexpensive, reproducible, and provides an ample supply of high quality spores. Due to the current use of porcelain carriers for testing C. sporogenes, it is advisable to retain the use of porcelain carriers until stainless steel can be evaluated as a replacement carrier material for Clostridium. The evaluation of stainless steel for Clostridium has been initiated by the Study Director. Study Director recommendations for First Action revisions are provided in a modified method.

  6. Antibiotic resistance genes fate and removal by a technological treatment solution for water reuse in agriculture.

    PubMed

    Luprano, Maria Laura; De Sanctis, Marco; Del Moro, Guido; Di Iaconi, Claudio; Lopez, Antonio; Levantesi, Caterina

    2016-11-15

    In order to mitigate the potential effects on the human health which are associated to the use of treated wastewater in agriculture, antibiotic resistance genes (ARGs) are required to be carefully monitored in wastewater reuse processes and their spread should be prevented by the development of efficient treatment technologies. Objective of this study was the assessment of ARGs reduction efficiencies of a novel technological treatment solution for agricultural reuse of municipal wastewaters. The proposed solution comprises an advanced biological treatment (Sequencing Batch Biofilter Granular Reactor, SBBGR), analysed both al laboratory and pilot scale, followed by sand filtration and two different disinfection final stages: ultraviolet light (UV) radiation and peracetic acid (PAA) treatments. By Polymerase Chain Reaction (PCR), the presence of 9 ARGs (ampC, mecA, ermB, sul1, sul2, tetA, tetO, tetW, vanA) were analysed and by quantitative PCR (qPCR) their removal was determined. The obtained results were compared to the reduction of total bacteria (16S rDNA gene) and of a faecal contamination indicator (Escherichia coli uidA gene). Only four of the analysed genes (ermB, sul1, sul2, tetA) were detected in raw wastewater and their abundance was estimated to be 3.4±0.7 x10(4) - 9.6±0.5 x10(9) and 1.0±0.3 x10(3) to 3.0±0.1 x10(7) gene copies/mL in raw and treated wastewaters, respectively. The results show that SBBGR technology is promising for the reduction of ARGs, achieving stable removal performance ranging from 1.0±0.4 to 2.8±0.7 log units, which is comparable to or higher than that reported for conventional activated sludge treatments. No reduction of the ARGs amount normalized to the total bacteria content (16S rDNA), was instead obtained, indicating that these genes are removed together with total bacteria and not specifically eliminated. Enhanced ARGs removal was obtained by sand filtration, while no reduction was achieved by both UV and PAA disinfection treatments tested in our study. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Comparison of byproduct formation in waters treated with chlorine and iodine: relevance to point-of-use treatment.

    PubMed

    Smith, Emma Marie; Plewa, Michael J; Lindell, Crystal L; Richardson, Susan D; Mitch, William A

    2010-11-15

    Due to their efficacy in deactivating a range of microbial pathogens, particularly amoebic cysts, iodine-based disinfectants have been a popular option for point-of-use (POU) drinking water disinfection by campers, the military, and rural consumers in developing countries. Recently, concerns regarding the formation of cytotoxic and genotoxic iodinated disinfection byproducts (I-DBPs) have arisen during chloramine disinfection of iodide-containing waters in the developed world; similar concerns should pertain to iodine-based POU disinfection. Because there are alternative POU disinfection techniques, including chlorine-based disinfectants, this paper compared disinfection byproduct formation from a range of iodine-based disinfectants at their recommended dosages to chlorination and chloramination under overdosing conditions. Just as chloroform was the predominant trihalomethane (THM) forme during chlorination or chloramination, iodoform was the predominant THM formed during iodination. Conditions fostering THM formation were similar between these treatments, except that THM formation during chlorination increased with pH, while it was slightly elevated at circumneutral pH during iodination. Iodoform formation during treatment with iodine tincture was higher than during treatment with iodine tablets. On a molar basis, iodoform formation during treatment with iodine tincture was 20-60% of the formation of chloroform during chlorination, and total organic iodine (TOI) formation was twice that of total organic chlorine (TOCl), despite the 6-fold higher oxidant dose during chlorination. Based upon previous measurements of chronic mammalian cell cytotoxicity for the individual THMs, consumers of two waters treated with iodine tincture would receive the same THM-associated cytotoxic exposure in 4-19 days as a consumer of the same waters treated with a 6-fold higher dose of chlorine over 1 year. Iodoacetic acid, diiodoacetic acid, and other iodo-acids were also formed with iodine tincture treatment, but at levels <11% of iodoform. However, testing of a Lifestraw Personal POU device, which combines an iodinated anion exchange resin with activated carbon post-treatment, indicated minimal formation of I-DBPs and no iodine residual. Although N-nitrosamines have been associated with oxidant contact with anion exchange resins, N-nitrosamine formation rapidly declined to low levels (4 ng/L) using the Lifestraw device after the first few flushes of water.

  8. IDENTIFICATION OF CHLORINE DIOXIDE DRINKING WATER DISINFECTION BY-PRODUCTS FORMED AT HIGH BROMIDE LEVELS

    EPA Science Inventory

    Due to concern over the potential adverse health effects of trihalomethanes (THMs), haloacetic acids, and other chlorinated by-products in chlorinated drinking water, alternative disinfection methods are being explored. Chlorine dioxide is a popular alternative, with over 500 dri...

  9. Mechanisms of ultraviolet disinfection and chlorination of Escherichia coli: Culturability, membrane permeability, metabolism, and genetic damage.

    PubMed

    Xu, Limei; Zhang, Chongmiao; Xu, Pengcheng; Wang, Xiaochang C

    2018-03-01

    Traditional culture methods may underestimate the tolerance of microorganisms to disinfectants because of the existence of viable but nonculturable or sublethally injured cells after disinfection. The selection of a strict method is crucial for the evaluation of disinfection performance. The actions of 2 typical disinfectants - ultraviolet (UV) and chlorine - on the fecal indicator Escherichia coli were investigated by the detection of culturability, membrane permeability, metabolic activity, deoxyribonucleic acid (DNA), and messenger ribonucleic acid (mRNA). During UV disinfection, the irreversible damages in the cell membrane and cellular adenosine triphosphate (ATP) were negligible at low UV doses (<80mJ/cm 2 ). However, membrane permeability was damaged at low doses of chlorine (<5mg/L), leading to leakage of cellular ATP. Our study showed that a slight lesion in DNA was detected even at high doses of UV (400mJ/cm 2 ) and chlorine (>5mg/L) treatments. The decay of mRNA was more rapid than that of DNA. The degradation level of mRNA depended on the choice of target genes. After exposure to 50mJ/cm 2 UV dose or 5mg/L chlorine for 30min, the DNA damage repair function (RecA mRNA) was inhibited. The mRNA involved in the DNA damage repair function can be a potential indicator of bacterial viability. Copyright © 2017. Published by Elsevier B.V.

  10. Seasonal evaluation of disinfection by-products throughout two full-scale drinking water treatment plants.

    PubMed

    Zhong, Xin; Cui, Chongwei; Yu, Shuili

    2017-07-01

    Carbonyl compounds can occur alpha-hydrogens or beta-diketones substitution reactions with disinfectants contributed to halogenated by-products formation. The objective of this research was to study the occurrence and fate of carbonyl compounds as ozonation by-products at two full-scale drinking water treatment plants (DWTPs) using different disinfectants for one year. The quality of the raw water used in both plants was varied according to the season. The higher carbonyl compounds concentrations were found in raw water in spring. Up to 15 (as the sum of both DWTPs) of the 24 carbonyl compounds selected for this work were found after disinfection. The dominant carbonyl compounds were formaldehyde, glyoxal, methyl-glyoxal, fumaric, benzoic, protocatechuic and 3-hydroxybenzoic acid at both DWTPs. In the following steps in each treatment plant, the concentration patterns of these carbonyl compounds differed depending on the type of disinfectant applied. Benzaldehyde was the only aromatic aldehyde detected after oxidation with ozone in spring. As compared with DWTP 1, five new carbonyl compounds were formed (crotonaldehyde, benzaldehyde, formic, oxalic and malonic acid) disinfection by ozone, and the levels of the carbonyl compounds increased. In addition, pre-ozonation (PO) and main ozonation (OZ) increased the levels of carbonyl compounds, however coagulation/flocculation (CF), sand filtration (SF) and granular activated carbon filtration (GAC) decreased the levels of carbonyl compounds. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Application of slightly acidic electrolyzed water for inactivating microbes in a layer breeding house.

    PubMed

    Hao, X X; Li, B M; Wang, C Y; Zhang, Q; Cao, W

    2013-10-01

    Lots of microorganisms exist in layer houses can cause bird diseases and worker health concerns. Spraying chemical disinfectants is an effective way to decontaminate pathogenic microorganisms in the air and on surfaces in poultry houses. Slightly acidic electrolyzed water (SAEW, pH 5.0-6.5) is an ideal, environmentally friendly broad-spectrum disinfectant to prevent and control bacterial or viral infection in layer farms. The purpose of this work was to investigate the cleaning effectiveness of SAEW for inactivating the microbes in layer houses. The effect of SAEW was evaluated by solid materials and surface disinfection in a hen house. Results indicate that SAEW with an available chlorine concentration of 250 mg/L, pH value of 6.19, and oxygen reduction potential of 974 mV inactivated 100% of bacteria and fungi in solid materials (dusts, feces, feather, and feed), which is more efficient than common chemical disinfectant such as benzalkonium chloride solution (1:1,000 vol/vol) and povidone-iodine solution (1:1,000 vol/vol). Also, it significantly reduced the microbes on the equipment or facility surfaces (P < 0.05), including floor, wall, feed trough, and water pipe surfaces. Moreover, SAEW effectively decreased the survival rates of Salmonella and Escherichia coli by 21 and 16 percentage points. In addition, spraying the target with tap water before disinfection plays an important role in spray disinfection.

  12. Subchronic toxicity study of ozonated and ozonated/chlorinated humic acids in Sprague-Dawley rats: A model system for drinking water disinfection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daniel, F.B.; Robinson, M.; Ringhand, H.P.

    Male and female Sprague-Dawley rats were administered drinking water containing humic acids either non-disinfected for following ozonation (O{sub 3}) or ozonation/chlorination (O{sub 3}/Cl{sub 2}) for 90 consecutive days. Test animals drank either of two concentrations of humic acids, 0.25 and 1.0 g/L total organic carbon (TOC), while controls received phosphate-buffered, distilled water. No consistent significant treatment-related effects were observed in body weight gain, organ weights, food or water consumption, or hematological and clinical chemistry parameters. No target organs were identified from the histopathological examination of the tissues. The most significant observation, an increase in liver to body weight ratio formore » the male animals in the 1.0 g/L O{sub 3}/Cl{sub 2} humic acid group, was not observed in any other group, nor was it corroborated via any biochemical measurements or histopathological analysis. Kidney lesions, primarily chronic progressive nephropathy, were a common observation in both controls and treated groups with no apparent relationship to either humic acid concentration or the disinfection process.« less

  13. Switching catalysis from hydrolysis to perhydrolysis in P. fluorescens esterase

    PubMed Central

    Yin, De Lu (Tyler); Bernhardt, Peter; Morley, Krista L.; Jiang, Yun; Cheeseman, Jeremy D.; Purpero, Vincent; Schrag, Joseph D.; Kazlauskas, Romas J.

    2010-01-01

    Many serine hydrolases catalyze perhydrolysis – the reversible formation of per-acids from carboxylic acids and hydrogen peroxide. Recently we showed that a single amino acid substitution in the alcohol binding pocket - L29P - in Pseudomonas fluorescens (SIK WI) aryl esterase (PFE) increased the specificity constant of PFE for peracetic acid formation >100-fold [Bernhardt et al. Angew. Chem. Intl. Ed. 2005, 44, 2742]. In this paper, we extend this work to address the three following questions. First, what is the molecular basis of the increase in perhydrolysis activity? We previously proposed that the L29P substitution creates a hydrogen bond between the enzyme and hydrogen peroxide in the transition state. Here we report two x-ray structures of L29P PFE that support this proposal. Both structures show a main chain carbonyl oxygen closer to the active-site serine as expected. One structure further shows acetate in the active site in an orientation consistent with reaction by an acyl-enzyme mechanism. We also detected an acyl-enzyme intermediate in the hydrolysis of ε-caprolactone by mass spectrometry. Second, can we further increase perhydrolysis activity? We discovered that the reverse reaction – hydrolysis of peracetic acid to acetic acid and hydrogen peroxide – occurs at nearly the diffusion limited rate. Since the reverse reaction cannot increase further, neither can the forward reaction. Consistent with this prediction, two variants with additional amino acid substitutions showed two fold higher kcat, but Km also increased so the specificity constant, kcat/Km, remained similar. Third, how does the L29P substitution change the esterase activity? Ester hydrolysis decreased for most esters (75-fold for ethyl acetate), but not for methyl esters. In contrast, L29P PFE catalyzed hydrolysis of ε-caprolactone five times more efficiently than wild-type PFE. Molecular modeling suggests that moving the carbonyl group closer to the active site blocks access for larger alcohol moieties, but binds ε-caprolactone more tightly. These results are consistent with the natural function of perhydrolases being either hydrolysis of peroxycarboxylic acids or hydrolysis of lactones. PMID:20112920

  14. EFFECTS OF DEFINED MIXTURES OF TRIHALOMETHANES AND HALOACETIC ACIDS ON PREGNANCY MAINTENANCE AND EYE DEVELOPMENT IN F 344 RATS

    EPA Science Inventory

    Although disinfection of drinking water is important for control of microbial contamination, it results in the formation of hundreds of disinfection by-products (DBPs). The most prevalent DBPs are trihalomethanes (THMs; chloroform, bromodichloromethane, chlorodibromomethane, bro...

  15. IDENTIFICATION OF PROTEINS INVOLVED IN TESTICULAR TOXICITY INDUCED BY HALOACID BY-PRODUCTS OF DRINKING WATER DISINFECTION

    EPA Science Inventory

    Dibromoacetic acid (DBA), a prevalent disinfection by-product in drinking water, perturbs spermiogenesis in adult rats suggesting that Sertoli-germ cell communication is compromised. When isolated seminiferous tubules from rats exposed to DBA in vivo were cultured, quantitative a...

  16. Influence of ozone and paracetic acid disinfection on adhesion of resilient liners to acrylic resin.

    PubMed

    Ekren, Orhun; Ozkomur, Ahmet

    2016-08-01

    The aim of this study was to evaluate the effect of paracetic acid (PAA) and ozone disinfection on the tensile bond strength (TBS) of silicone-based resilient liners to acrylic resins. One hundred and twenty dumbbell shaped heat-polymerized acrylic resins were prepared. From the mid segment of the specimens, 3 mm of acrylic were grinded off and separated parts were reattached by resilient liners. The specimens were divided into 2 control (control1, control7) and 4 test groups of PAA and ozone disinfection (PAA1, PAA7, ozone1 and ozone7; n=10). While control groups were immersed in distilled water for 10 min (control1) and 7 days (control7), test groups were subjected to PAA (16 g/L) or ozone rich water (4 mg/L) for 1 cycle (10 min for PAA and 60 min for ozone) per day for 7 days prior to tensile tests. Measurements of the TBS were analyzed using 3-way ANOVA and Tukey's HSD test. Adhesive strength of Mollosil decreased significantly by application of ozone disinfection. PAA disinfection had no negative effect on the TBS values of Mollosil and Molloplast B to acrylic resin. Single application of ozone disinfection did not have any negative effect on TBS values of Molloplast B, but prolonged exposure to ozone decreased its adhesive strength. The adhesion of resilient liners to acrylic was not adversely affected by PAA disinfection. Immersion in ozonated water significantly decreased TBS of Mollosil. Prolonged exposure to ozone negatively affects adhesion of Molloplast B to denture base materials.

  17. Inhibition of trihalomethane formation in city water by radiation-ozone treatment and rapid composting of radiation disinfected sewage sludge

    NASA Astrophysics Data System (ADS)

    Takehisa, M.; Arai, H.; Arai, M.; Miyata, T.; Sakumoto, A.; Hashimoto, S.; Nishimura, K.; Watanabe, H.; Kawakami, W.; Kuriyama, I.

    Humic acid and Fulvic acid in natural water are precursors of carcinogenic THM which is formed during chlorine disinfection in city water processing. The radiation-oxidation process in the presence of ozone is effective to remove the precursors. The THM formation was reduced more than the decrease in TOC by the combination treatment. This is mainly due to a change in the chemical structure of the oxidation products. A composting of radiation disinfected sludge cake for agricultural reuse could be achieved within 3 days primary fermentation in a sewage plant. The rapid fermentation with use of radiation is effective to scale down of a fermentor of composting plant and the process reduces a health risk from the workers as well as final users.

  18. EVALUATION OF CHEMICALS USED FOR DRINKING WATER DISINFECTION FOR PRODUCTION OF CHROMOSOMAL DAMAGE AND SPERM-HEAD ABNORMALITIES IN MICE

    EPA Science Inventory

    Chemical oxidants are commonly added during water treatment for disinfection purposes. These chemicals have not been tested previously for their ability to induce genetic damage in vivo. Chlorine (hypochlorite and hypochlorous acid), monochloramine, chlorine dioxide, sodium chlor...

  19. Formation of Toxic Iodinated Disinfection By-Products from Compounds Used in Medical Imaging

    EPA Science Inventory

    Iodinated X-ray contrast media (ICM) were investigated as a source of iodine in the formation of iodo-trihalomethane (iodo-THM) and iodo-acid disinfection byproducts (DBPs), both of which are highly genotoxic and/or cytotoxic in mammalian cells. ICM are widely used at medical cen...

  20. Use of Normal Human Colon Cells to Assess Toxicities of Unregulated Disinfection By-products and Mixtures

    EPA Science Inventory

    The discovery of chlorination and chloramination by-products other than the regulated trihalomethanes and haloacetic acids has created a need for short-term in vitro assays to address toxicities that might be associated with human exposure. Approximately 600 disinfection by-produ...

  1. Reproductive toxicity of a mixture of regulated drinking-water disinfection by-products in a multigenerational rat bioassay

    EPA Science Inventory

    BACKGROUND:Trihalomethanes (THMs) and haloaretic acids (HAAs) are regulated disinfection by-products (DBPs); their joint reproductive toxicity in drinking water is unknown.OBJECTIVE: We aimed to evaluate a drinking water mixture of the four regulated THMs and five regulated HAAs ...

  2. EVALUATION OF THE JOINT TOXIC ACTION OF MIXTURES OF HALOACETIC ACIDS CONSTRUCTED USING ENVIRONMENTAL CONCENTRATION/EXPOSURE DATA

    EPA Science Inventory

    Disinfection byproducts (DBPs) are formed by reactions between chemicals used to disinfect water and organic compounds present in source water. The composition of DBP mixtures varies based on a number of factors, including treatment scenario, with different DBP mixtures contain...

  3. Effect of drinking water disinfection by-products in human peripheral blood lymphocytes and sperm.

    PubMed

    Ali, Aftab; Kurzawa-Zegota, Malgorzata; Najafzadeh, Mojgan; Gopalan, Rajendran C; Plewa, Michael J; Anderson, Diana

    2014-12-01

    Drinking water disinfection by-products (DBPs) are generated by the chemical disinfection of water and may pose hazards to public health. Two major classes of DBPs are found in finished drinking water: haloacetic acids (HAAs) and trihalomethanes (THMs). HAAs are formed following disinfection with chlorine, which reacts with iodide and bromide in the water. Previously the HAAs were shown to be cytotoxic, genotoxic, mutagenic, teratogenic and carcinogenic. To determine the effect of HAAs in human somatic and germ cells and whether oxidative stress is involved in genotoxic action. In the present study both somatic and germ cells have been examined as peripheral blood lymphocytes and sperm. The effects of three HAA compounds: iodoacetic acid (IAA), bromoacetic acid (BAA) and chloroacetic acid (CAA) were investigated. After determining appropriate concentration responses, oxygen radical involvement with the antioxidants, butylated hydroxanisole (BHA) and the enzyme catalase, were investigated in the single cell gel electrophoresis (Comet) assay under alkaline conditions, >pH 13 and the micronucleus assay. In the Comet assay, BHA and catalase were able to reduce DNA damage in each cell type compared to HAA alone. In the micronucleus assay, micronuclei (MNi) were found in peripheral lymphocytes exposed to all three HAAs and catalase and BHA were in general, able to reduce MNi induction, suggesting oxygen radicals play a role in both assays. These observations are of concern to public health since both human somatic and germ cells show similar genotoxic responses. Copyright © 2014. Published by Elsevier B.V.

  4. AOAC method 966.04: preliminary evaluation of cooked meat medium with manganese sulfate for the cultivation of Clostridium sporogenes: precollaborative study.

    PubMed

    Tomasino, Stephen F; Samalot-Freire, Luisa C

    2007-01-01

    AOAC Method 966.04, the Sporicidal Activity of Disinfectants Test, is a carrier-based test that provides a qualitative measure of product efficacy against spores of Bacillus subtilis and Clostridium sporogenes. For regulatory purposes, Method 966.04 is accepted by the U.S. Environmental Protection Agency (EPA) and the U.S. Food and Drug Administration (FDA) for the generation of product performance data for sporicides and sterilants. In this study, we report on findings associated with proposed improvements (modifications) to the Clostridium component of the method. Egg meat medium (EMM), the culture medium for C. sporogenes currently specified in the method, is no longer commercially available and finding a suitable replacement is critical. In addition, the use of a nonstandardized extract of raw soil as an amendment to EMM, as stipulated in the current method, may result in a highly variable spore suspension. The primary focus of this study was to find replacements for EMM and soil extract. A carrier count procedure, the establishment of target carrier counts (spores/carrier), and a neutralization confirmation procedure were also evaluated. The study was limited to liquid products tested against Clostridium on a hard surface carrier (porcelain penicylinder). Spore suspensions of C. sporogenes were generated using: (1) EMM with soil extract (EMM/SE), (2) cooked meat medium with soil extract (CMM/SE), and (3) cooked meat medium with 5 microg/mL manganese sulfate (CMM/MnSO4). The titer of the spore suspension, carrier counts, resistance to hydrochloric acid (HCI), and efficacy against 3 liquid sporicidal agents were used to evaluate the potential of CMM and MnSO4 as replacements. The study was performed by the EPA Office of Pesticide Programs Microbiology Laboratory, Fort Meade, MD. Use of CMM/SE and CMM/MnSO4 resulted in comparable results for titer of spore suspensions (approximately 10(8) spores/mL) and carrier counts (approximately 3 x 10(6) spores/carrier). The carrier counts for the EMM/SE were approximately 1 log lower than CMM-based treatments; however, no attempt was made to dilute the CMM spore suspensions prior to carrier inoculation to reduce the carrier counts for CMM. Resistance of spores to 2.5 M HCI was acceptable across the 3 media types. Treatments for comparative efficacy testing were designed to provide a range of sporicidal activity, i.e., high and low efficacy treatments. Sodium hypochlorite (bleach), hydrogen peroxide/peracetic acid, and glutaraldehyde were used as test chemicals. The number of carriers resulting in growth (positive) for the low treatments for all 3 chemicals ranged from 9 to 59 out of 60 across the 3 media types--EMM exhibited fewer positives overall. The high efficacy treatments for sodium hypochlorite and hydrogen peroxide/peracetic acid yielded a range of 0 to 2 positives out of 60 across the 3 media. However, the high glutaraldehyde treatment generated 3, 20, and 20 positives out of 60 for the EMM/SE, CMM/SE, and CMM/MnSO4, respectively. The lower number of positive carriers for EMM/SE may be due to the reduced carrier counts. CMM, either with SE or MnSO4, appears to be a suitable replacement for EMM/SE. On the basis of the results of this study, the Study Director recommends that CMM/MnSO4 and the spore enumeration target carrier count and neutralization procedures be considered for collaborative study to officially modify the Clostridium x porcelain component of Method 966.04.

  5. Factors affecting the water odor caused by chloramines during drinking water disinfection.

    PubMed

    Wang, An-Qi; Lin, Yi-Li; Xu, Bin; Hu, Chen-Yan; Gao, Ze-Chen; Liu, Zhi; Cao, Tong-Cheng; Gao, Nai-Yun

    2018-10-15

    Chloramine disinfection is one of the most common disinfection methods in drinking water treatment. In this study, the temporal variability of water odors during monochloramine auto-decomposition was investigated to elucidate the characteristics of odor problems caused by adopting chloramine disinfection in tap water. Odor intensities and dominant odorant contributions were determined using the flavor profile analysis (FPA) and odor active value (OAV), respectively. During auto-decomposition of monochloramine, Cl 2 /N molar ratio, pH, temperature, and the presence of NOM all affected odor intensity and odor temporal variation in drinking water. In general, decreasing pH from 8.5 to 6.0 led to increasing perceived odor intensity due to the formation of dichloramine. The major odorants responsible for chlorinous odor under acidic and non-acidic conditions were dichloramine and monochloramine, respectively. Chloraminated water with a Cl 2 /N molar ratio of 0.6 or NOM concentration <2 mg-C L -1 inhibited odor intensity. Furthermore, the influence of rechlorination on chlorinous odor intensity for chloraminated water should not be neglected. The results of this study will be beneficial for the control of chlorinous odors caused by chloramine disinfection in drinking water. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Inactivation of biofilm bacteria.

    PubMed Central

    LeChevallier, M W; Cawthon, C D; Lee, R G

    1988-01-01

    The current project was developed to examine inactivation of biofilm bacteria and to characterize the interaction of biocides with pipe surfaces. Unattached bacteria were quite susceptible to the variety of disinfectants tested. Viable bacterial counts were reduced 99% by exposure to 0.08 mg of hypochlorous acid (pH 7.0) per liter (1 to 2 degrees C) for 1 min. For monochloramine, 94 mg/liter was required to kill 99% of the bacteria within 1 min. These results were consistent with those found by other investigators. Biofilm bacteria grown on the surfaces of granular activated carbon particles, metal coupons, or glass microscope slides were 150 to more than 3,000 times more resistant to hypochlorous acid (free chlorine, pH 7.0) than were unattached cells. In contrast, resistance of biofilm bacteria to monochloramine disinfection ranged from 2- to 100-fold more than that of unattached cells. The results suggested that, relative to inactivation of unattached bacteria, monochloramine was better able to penetrate and kill biofilm bacteria than free chlorine. For free chlorine, the data indicated that transport of the disinfectant into the biofilm was a major rate-limiting factor. Because of this phenomenon, increasing the level of free chlorine did not increase disinfection efficiency. Experiments where equal weights of disinfectants were used suggested that the greater penetrating power of monochloramine compensated for its limited disinfection activity. These studies showed that monochloramine was as effective as free chlorine for inactivation of biofilm bacteria. The research provides important insights into strategies for control of biofilm bacteria. Images PMID:2849380

  7. Efficacy of a variety of disinfectants against Listeria spp.

    PubMed

    Best, M; Kennedy, M E; Coates, F

    1990-02-01

    The efficacy of 14 disinfectants against Listeria innocua and two strains of Listeria monocytogenes in the presence of organic matter was studied. Quantitative efficacy tests were used. Many of the disinfectants tested were not as effective on Listeria spp. when the test organisms were dried onto the surface of steel disks (carrier tests) as they were when the organisms were placed in suspension (suspension test). The presence of whole serum and milk (2% fat) further reduced the disinfectant capacities of most of the formulations studied. Only three disinfectants (povidone-iodine, chlorhexidine gluconate, and glutaraldehyde) were effective in the carrier test in the presence of serum; however, all three were ineffective when challenged with milk (2% fat). Only one solution, sodium dichloroisocyanurate, was effective in the presence of milk. All but four formulations (chloramine-T, phosphoric acid, an iodophor, and formaldehyde) were effective in the suspension tests, regardless of the organic load. L. monocytogenes was observed to be slightly more resistant to disinfection than L. innocua was. There was no difference in disinfectant susceptibility between the two strains of L. monocytogenes. These findings emphasize the need for caution in selecting an appropriate disinfectant for use on contaminated surfaces, particularly in the presence of organic material.

  8. Biodiesel from wastewater: lipid production in high rate algal pond receiving disinfected effluent.

    PubMed

    Assemany, Paula Peixoto; Calijuri, Maria Lucia; do Couto, Eduardo de Aguiar; Santiago, Aníbal Fonseca; Dos Reis, Alberto José Delgado

    2015-01-01

    The production of different species of microalgae in consortium with other micro-organisms from wastewaters may represent an alternative process, to reduce the costs, for obtaining biofuels. The aim of this study was to evaluate the influence of pre-ultraviolet disinfection (UV) in the production of lipids from biomass produced in high rate ponds. Two high rate algal ponds were evaluated: a pond that received domestic sewage without disinfection and the other receiving domestic sewage previously disinfected by UV radiation (uvHRAP). The UV disinfection did not lead to significant differences in fatty acid profile and total lipid productivities, although it increased algal biomass concentration and productivity as well as lipid content. Moreover, the overall biomass concentrations and productivities decreased with the UV disinfection, mostly as a consequence of a loss in bacterial load. We thus conclude that uvHRAP disinfection may represent a potential strategy to promote the cleaner and safer growth of algal biomass when cultivated in consortium with other micro-organisms. Mainly regarding the use of wastewater as culture medium, together with a cheaper production of lipids for biodiesel, pre-disinfection may represent an advance since extraction costs could be significantly trimmed due to the increase in lipid content.

  9. Occurrence and Mammalian Cell Toxicity of Iodinated Disinfection Byproducts in Drinking Water

    EPA Science Inventory

    An occurrence study was conducted to measure five iodo-acids (iodoacetic acid, bromoiodoacetic acid, (Z)-3-bromo-3-iodo-propenoic acid, (E)-3-bromo-3-iodo-propenoic acid, and (E)-2-iodo-3-methylbutenedioic acid) and two iodo-trihalomethanes (iodo-THMs), (dichloroiodomethane and b...

  10. Determination of several common disinfection by-products in frozen foods.

    PubMed

    Cardador, Maria Jose; Gallego, Mercedes

    2018-01-01

    Disinfected water and/or disinfectants are commonly used by the freezing industry in such processes as sanitising, washing, blanching, cooling and transporting the final product. For this reason, disinfection by-products (DBPs) can be expected in frozen foods. This study focused on the presence of DBPs in a wide variety of frozen vegetables, meats and fish. For this purpose, the 14 halogenated DBPs more prevalent in disinfected water were selected (four trihalomethanes, seven haloacetic acids, two haloacetonitriles and trichloronitromethane). Up to seven DBPs were found in vegetables, whereas only four DBPs were present in meats and fish, and at lower concentrations, since their contact with disinfected water is lower than in frozen vegetables. It is important to emphasise that trichloronitromethane (the most abundant nitrogenous DBP in disinfected water) was found for the first time in foods. Finally, it was concluded that the freezing process can keep the compounds stable longer than other preservation processes (viz. sanitising, canning) and, therefore, frozen foods present higher DBP concentrations than other food categories (minimally processed vegetables, or canned vegetables and meats).

  11. 9 CFR 96.13 - Uncertified casings; disinfection with hydrochloric acid.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...) Disinfect the casings in a solution made as follows: Dissolve 90 pounds common salt in 100 gallons water and... solution shall be discarded unless means are provided for accurately determining the loss of strength. In event means for accurately determining loss of strength are provided it will be permissible to restore...

  12. Novel mechanisms of biotransformation of p-tert-amylphenol by bacteria and fungi with special degradation abilities and simultaneous detoxification of the disinfectant.

    PubMed

    Schlueter, Rabea; Röder, Anja; Czekalski, Nadine; Gliesche, Daniel; Mikolasch, Annett; Schauer, Frieder

    2014-01-01

    The compound p-tert-amylphenol (p-(1,1-dimethylpropyl)phenol) is a widely used disinfectant belonging to the group of short branched-chain alkylphenols. It is produced in or imported into the USA with more than one million pounds per year and can be found in the environment in surface water, sediments, and soil. We have investigated for the first time the biotransformation of this disinfectant and the accumulation of metabolites by five bacterial strains, three yeast strains, and three filamentous fungi, selected because of their ability to transform either aromatic or branched-chain compounds. Of the 11 microorganisms tested, one yeast strain and three bacteria could not transform the disinfectant despite of a very low concentration applied (0.005%). None of the other seven organisms was able to degrade the short branched alkyl chain of p-tert-amylphenol. However, two yeast strains, two filamentous fungi, and two bacterial strains attacked the aromatic ring system of the disinfectant via the hydroxylated intermediate 4-(1,1-dimethyl-propyl)-benzene-1,2-diol resulting in two hitherto unknown ring fission products with pyran and furan structures, 4-(1,1-dimethyl-propyl)-6-oxo-6-H-pyran-2-carboxylic acid and 2-[3-(1,1-dimethyl-propyl)-5-oxo-2H-furan-2-yl]acetic acid. While the disinfectant was toxic to the organisms applied, one of the ring cleavage products was not. Thus, a detoxification of the disinfectant was achieved by ring cleavage. Furthermore, one filamentous fungus formed sugar conjugates with p-tert-amylphenol as another mechanism of detoxification of toxic environmental pollutants. With this work, we can also contribute to the allocation of unknown chemical compounds within environmental samples to their parent compounds.

  13. OCCURRENCE OF IODO-ACID AND IODO-THM DBPS IN U. S. CHLORAMINATED DRINKING WATERS

    EPA Science Inventory

    Iodo-acids were recently identified for the first time as DBPs in drinking water disinfected with chloramines. The iodo-acids identified included iodoacetic acid (IAA), bromoiodoacetic acid, (E)-3-bromo-3-iodo-propenoic acid, (Z)-3-bromo-3-iodo-propenoic acid, and (E)-2-iodo-3...

  14. Dental unit waterlines disinfection using hypochlorous acid-based disinfectant

    PubMed Central

    Shajahan, Irfana Fathima; Kandaswamy, D; Srikanth, Padma; Narayana, L Lakshmi; Selvarajan, R

    2016-01-01

    Objective: The purpose of the study was to investigate the efficacy of a new disinfectant to disinfect the dental unit waterlines. Materials and Methods: New dental unit waterlines were installed in 13 dental chairs, and biofilm was allowed to grow for 10 days. Disinfection treatment procedure was carried out in the 12 units, and one unit was left untreated. The dental unit waterlines were removed and analyzed using the scanning electron microscope (SEM) (TESCAN VEGA3 SBU). Result: On examination, SEM images showed that there was no slime layer or bacterial cells seen in any of the 12 cut sections obtained from the treated dental waterlines which mean that there was no evident of biofilm formation. Untreated dental unit waterlines showed a microbial colonization with continuous filamentous organic matrix. There was significant biofilm formation in the control tube relative to the samples. Conclusion: The tested disinfectant was found to be effective in the removal of biofilm from the dental unit waterlines. PMID:27563184

  15. Haloacetic Acid Water Disinfection Byproducts Affect Pyruvate Dehydrogenase Activity and Disrupt Cellular Metabolism.

    PubMed

    Dad, Azra; Jeong, Clara H; Wagner, Elizabeth D; Plewa, Michael J

    2018-02-06

    The disinfection of drinking water has been a major public health achievement. However, haloacetic acids (HAAs), generated as byproducts of water disinfection, are cytotoxic, genotoxic, mutagenic, carcinogenic, and teratogenic. Previous studies of monoHAA-induced genotoxicity and cell stress demonstrated that the toxicity was due to inhibition of glyceraldehyde-3-phosphate dehydrogenase (GAPDH), leading to disruption of cellular metabolism and energy homeostasis. DiHAAs and triHAAs are also produced during water disinfection, and whether they share mechanisms of action with monoHAAs is unknown. In this study, we evaluated the effects of mono-, di-, and tri-HAAs on cellular GAPDH enzyme kinetics, cellular ATP levels, and pyruvate dehydrogenase complex (PDC) activity. Here, treatments conducted in Chinese hamster ovary (CHO) cells revealed differences among mono-, di-, and triHAAs in their molecular targets. The monoHAAs, iodoacetic acid and bromoacetic acid, were the strongest inhibitors of GAPDH and greatly reduced cellular ATP levels. Chloroacetic acid, diHAAs, and triHAAs were weaker inhibitors of GAPDH and some increased the levels of cellular ATP. HAAs also affected PDC activity, with most HAAs activating PDC. The primary finding of this work is that mono- versus multi-HAAs address different molecular targets, and the results are generally consistent with a model in which monoHAAs activate the PDC through GAPDH inhibition-mediated disruption in cellular metabolites, including altering ATP-to-ADP and NADH-to-NAD ratios. The monoHAA-mediated reduction in cellular metabolites results in accelerated PDC activity by way of metabolite-ratio-dependent PDC regulation. DiHAAs and triHAAs are weaker inhibitors of GAPDH, but many also increase cellular ATP levels, and we suggest that they increase PDC activity by inhibiting pyruvate dehydrogenase kinase.

  16. 40 CFR 141.53 - Maximum contaminant level goals for disinfection byproducts.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... byproduct MCLG(mg/L) Bromodichloromethane zero Bromoform zero Bromate zero Chlorite 0.8 Chloroform 0.07 Dibromochloromethane 0.06 Dichloroacetic acid zero Monochloroacetic acid 0.07 Trichloroacetic acid 0.02 [63 FR 69465...

  17. 40 CFR 141.53 - Maximum contaminant level goals for disinfection byproducts.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... byproduct MCLG(mg/L) Bromodichloromethane zero Bromoform zero Bromate zero Chlorite 0.8 Chloroform 0.07 Dibromochloromethane 0.06 Dichloroacetic acid zero Monochloroacetic acid 0.07 Trichloroacetic acid 0.02 [63 FR 69465...

  18. 40 CFR 141.53 - Maximum contaminant level goals for disinfection byproducts.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... byproduct MCLG(mg/L) Bromodichloromethane zero Bromoform zero Bromate zero Chlorite 0.8 Chloroform 0.07 Dibromochloromethane 0.06 Dichloroacetic acid zero Monochloroacetic acid 0.07 Trichloroacetic acid 0.02 [63 FR 69465...

  19. 40 CFR 141.53 - Maximum contaminant level goals for disinfection byproducts.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... byproduct MCLG(mg/L) Bromodichloromethane zero Bromoform zero Bromate zero Chlorite 0.8 Chloroform 0.07 Dibromochloromethane 0.06 Dichloroacetic acid zero Monochloroacetic acid 0.07 Trichloroacetic acid 0.02 [63 FR 69465...

  20. Inactivation of Foot-and-Mouth Disease Virus by Citric Acid and Sodium Carbonate with Deicers

    PubMed Central

    Hong, Jang-Kwan; You, Su-Hwa; Kim, Su-Mi; Tark, Dongseob; Lee, Hyang-Sim; Ko, Young-Joon; Seo, Min-Goo; Park, Jong-Hyeon; Kim, Byounghan

    2015-01-01

    Three out of five outbreaks of foot-and-mouth disease (FMD) since 2010 in the Republic of Korea have occurred in the winter. At the freezing temperatures, it was impossible to spray disinfectant on the surfaces of vehicles, roads, and farm premises because the disinfectant would be frozen shortly after discharge and the surfaces of the roads or machines would become slippery in cold weather. In this study, we added chemical deicers (ethylene glycol, propylene glycol, sodium chloride, calcium chloride, ethyl alcohol, and commercial windshield washer fluid) to keep disinfectants (0.2% citric acid and 4% sodium carbonate) from freezing, and we tested their virucidal efficacies under simulated cold temperatures in a tube. The 0.2% citric acid could reduce the virus titer 4 logs at −20°C with all the deicers. On the other hand, 4% sodium carbonate showed little virucidal activity at −20°C within 30 min, although it resisted being frozen with the function of the deicers. In conclusion, for the winter season, we may recommend the use of citric acid (>0.2%) diluted in 30% ethyl alcohol or 25% sodium chloride solvent, depending on its purpose. PMID:26319879

  1. [Control of disinfection in the buildings of pig farms].

    PubMed

    Maris, P

    1990-01-01

    A survey carried out in pig farms was undertaken in order to compare 4 disinfectants used in 13 disinfecting operations, during the vacation period. It was immediately noticeable that after swabbing and counting the staphylococci, the chloramine T-based preparation was more effective than the quaternary ammonium-aldehyde association, phenolic acid derivatives or the quaternary ammonium preparations. We then observed that although the number of organisms decreased by 99.8%, their number on slatted floors still ranged between 0.02 x 10(4) and 3 x 10(4) per cm2.

  2. Decontamination of materials contaminated with Francisella philomiragia or MS2 bacteriophage using PES-Solid, a solid source of peracetic acid.

    PubMed

    Buhr, T L; Young, A A; Johnson, C A; Minter, Z A; Wells, C M

    2014-08-01

    The aim of the study was to develop test methods and evaluate survival of Francisella philomiragia cells and MS2 bacteriophage after exposure to PES-Solid (a solid source of peracetic acid) formulations with or without surfactants. Francisella philomiragia cells (≥7·6 log10 CFU) or MS2 bacteriophage (≥6·8 log10 PFU) were deposited on seven different test materials and treated with three different PES-Solid formulations, three different preneutralized samples and filter controls at room temperature for 15 min. There were 0-1·3 log10 CFU (<20 cells) of cell survival, or 0-1·7 log10 (<51 PFU) of bacteriophage survival in all 21 test combinations (organism, formulation and substrate) containing reactive PES-Solid. In addition, the microemulsion (Dahlgren Surfactant System) showed ≤2 log10 (100 cells) of viable F. philomiragia cells, indicating the microemulsion achieved <2 log10 CFU on its own. Three PES-Solid formulations and one microemulsion system (DSS) inactivated F. philomiragia cells and/or MS2 bacteriophage that were deposited on seven different materials. A test method was developed to show that reactive PES-Solid formulations and a microemulsion system (DSS) inactivated >6 log10 CFU/PFU F. philomiragia cells and/or MS2 bacteriophage on different materials. Published 2014. This article is a U.S. Government work and is in the public domain in the USA.

  3. High yield hydrolysis of seaweed-waste biomass using peracetic acid and ionic liquid treatments

    NASA Astrophysics Data System (ADS)

    Uju, Wijayanta, Agung Tri; Goto, Masahiro; Kamiya, Noriho

    2018-02-01

    Seaweed is one of the most promising bioethanol feedstocks. This water plant has high carbohydrate content but low lignin content, as a result it will be easier to be hydrolysed. This paper described hydrolysis of seaweed-waste biomass from the carrageenan (SWBC) industry using enzymatic saccharification or ionic liquids-HCl hydrolysis. In the first work, SWBC pretreated by peracetic acid (PAA) followed by ionic liquid (IL) caused enhance the cellulose conversion of enzymatic saccharification. At 48h saccharification, the value conversion almost reached 100%. In addition, the untreated SWBC also produced the cellulose conversion 77%. In the second work, SWBC or Bagasse with or without pretreated by PAA was hydrolyzed using ILs-HCl hydrolysis. The ILs used were 1-buthyl-3-methylpyridium chloride, [Bmpy][Cl] and 1-butyl-3-metyl imidazolium chloride ([Bmim][Cl]). [Bmpy][Cl]-HCl hydrolysis produced higher cellulose conversion than [Bmim][Cl]-HCl hydrolysis. The phenomenon was clearly observed on the Bagasse, which without pretreated by PAA. Furthermore, SWBC hydrolyzed by both ILs in the presence low concentration of HCl produced cellulose conversion 70-98% at 60-90 min of hydrolysis time. High cellulose conversion of SWBC on the both hydrolysis was caused by SWBC had the low lignin (4%). Moreover, IL treatments caused lowering of cellulose hydrogen bonds or even changed the cellulose characteristics from cellulose I to cellulose II which easily to be hydrolyzed. In the case of [Bmpy][Cl], this IL may reduce the degree polymerization of celluloses.

  4. Unsaturated fatty acid, cis-2-decenoic acid, in combination with disinfectants or antibiotics removes pre-established biofilms formed by food-related bacteria.

    PubMed

    Sepehr, Shayesteh; Rahmani-Badi, Azadeh; Babaie-Naiej, Hamta; Soudi, Mohammad Reza

    2014-01-01

    Biofilm formation by food-related bacteria and food-related pathogenesis are significant problems in the food industry. Even though much disinfection and mechanical procedure exist for removal of biofilms, they may fail to eliminate pre-established biofilms. cis-2 decenoic acid (CDA), an unsaturated fatty acid messenger produced by Pseudomonas aeruginosa, is reportedly capable of inducing the dispersion of established biofilms by multiple types of microorganisms. However, whether CDA has potential to boost the actions of certain antimicrobials is unknown. Here, the activity of CDA as an inducer of pre-established biofilms dispersal, formed by four main food pathogens; Staphylococcus aureus, Bacillus cereus, Salmonella enterica and E. coli, was measured using both semi-batch and continuous cultures bioassays. To assess the ability of CDA combined biocides treatments to remove pre-established biofilms formed on stainless steel discs, CFU counts were performed for both treated and untreated cultures. Eradication of the biofilms by CDA combined antibiotics was evaluated using crystal violet staining. The effect of CDA combined treatments (antibiotics and disinfectants) on biofilm surface area and bacteria viability was evaluated using fluorescence microscopy, digital image analysis and LIVE/DEAD staining. MICs were also determined to assess the probable inhibitory effects of CDA combined treatments on the growth of tested microorganisms' planktonic cells. Treatment of pre-established biofilms with only 310 nM CDA resulted in at least two-fold increase in the number of planktonic cells in all cultures. While antibiotics or disinfectants alone exerted a trivial effect on CFU counts and percentage of surface area covered by the biofilms, combinational treatments with both 310 nM CDA and antibiotics or disinfectants led to approximate 80% reduction in biofilm biomass. These data suggests that combined treatments with CDA would pave the way toward developing new strategies to control biofilms with widespread applications in industry as well as medicine.

  5. Unsaturated Fatty Acid, cis-2-Decenoic Acid, in Combination with Disinfectants or Antibiotics Removes Pre-Established Biofilms Formed by Food-Related Bacteria

    PubMed Central

    Sepehr, Shayesteh; Rahmani-Badi, Azadeh; Babaie-Naiej, Hamta; Soudi, Mohammad Reza

    2014-01-01

    Biofilm formation by food-related bacteria and food-related pathogenesis are significant problems in the food industry. Even though much disinfection and mechanical procedure exist for removal of biofilms, they may fail to eliminate pre-established biofilms. cis-2 decenoic acid (CDA), an unsaturated fatty acid messenger produced by Pseudomonas aeruginosa, is reportedly capable of inducing the dispersion of established biofilms by multiple types of microorganisms. However, whether CDA has potential to boost the actions of certain antimicrobials is unknown. Here, the activity of CDA as an inducer of pre-established biofilms dispersal, formed by four main food pathogens; Staphylococcus aureus, Bacillus cereus, Salmonella enterica and E. coli, was measured using both semi-batch and continuous cultures bioassays. To assess the ability of CDA combined biocides treatments to remove pre-established biofilms formed on stainless steel discs, CFU counts were performed for both treated and untreated cultures. Eradication of the biofilms by CDA combined antibiotics was evaluated using crystal violet staining. The effect of CDA combined treatments (antibiotics and disinfectants) on biofilm surface area and bacteria viability was evaluated using fluorescence microscopy, digital image analysis and LIVE/DEAD staining. MICs were also determined to assess the probable inhibitory effects of CDA combined treatments on the growth of tested microorganisms' planktonic cells. Treatment of pre-established biofilms with only 310 nM CDA resulted in at least two-fold increase in the number of planktonic cells in all cultures. While antibiotics or disinfectants alone exerted a trivial effect on CFU counts and percentage of surface area covered by the biofilms, combinational treatments with both 310 nM CDA and antibiotics or disinfectants led to approximate 80% reduction in biofilm biomass. These data suggests that combined treatments with CDA would pave the way toward developing new strategies to control biofilms with widespread applications in industry as well as medicine. PMID:25000301

  6. Comparison of DNA damage in human-derived hepatoma line (HepG2) exposed to the fifteen drinking water disinfection byproducts using the single cell gel electrophoresis assay.

    PubMed

    Zhang, Li; Xu, Liang; Zeng, Qiang; Zhang, Shao-Hui; Xie, Hong; Liu, Ai-Lin; Lu, Wen-Qing

    2012-01-24

    Disinfection of drinking water reduces pathogenic infection, but generates disinfection by-products (DBPs) in drinking water. In this study, the effect of fifteen DBPs on DNA damage in human-derived hepatoma line (HepG2) was investigated by the single cell gel electrophoresis (SCGE) assay. These fifteen DBPs are: four trihalomethanes (THMs), six haloacetic acides (HAAs), three haloacetonitriles (HANs), 3-chloro-4-(dichloromethyl)-5-hydroxy-2(5H)-furanone (MX), and chloral hydrate (CH). Based on the minimal effective concentration (MEC) at which DBPs induced significant increase in olive tail moment (OTM), the rank order of DNA-damaging potency is: bromodichloromethane (BDCM)>dibromochloromethane (DBCM)>tribromomethane (TBM)>trichloromethane (TCM) of the four THMs; iodoacetic acid (IA)>bromoacetic acid (BA)>dibromoacetic acid (DBA)>dichloracetic acid (DCA)>trichloroacetic acid (TCA) of the five HAAs; dibromoacetonitrile (DBN)approximately dichloroacetonitrile (DCN)>trichloroacetonitrile (TCN) of the three HANs. The DNA damaging potency of MX and CH is similar to TCA and DCA, respectively. IA is the most genotoxic DBP in the fifteen DBPs, followed by BA. Chloroacetic acid (CA) is not genotoxic in this assay. Our findings indicated that HepG2/SCGE is a sensitive tool to evaluate the genotoxicity of DBPs and iodinated DBPs are more genotoxic than brominated DBPs, but chlorinated DBPs are less genotoxic than brominated DBPs. © 2011 Elsevier B.V. All rights reserved.

  7. Effects of different peracetic acid formulations on post space radicular dentin.

    PubMed

    Belizário, Lauriê Garcia; Kuga, Milton Carlos; Castro-Núñez, Gabriela Mariana; Escalante-Otárola, Wilfredo Gustavo; Só, Marcus Vinicius Reis; Pereira, Jefferson Ricardo

    2018-01-05

    The optimal irrigating solution with antimicrobial and dentin cleansing properties for post space preparation for fiber posts is unclear. Peracetic acid is one option but is available in various chemical formulations that require evaluation. The purpose of this in vitro study was to evaluate dentin surface cleanliness based on the presence of a smear layer and the number of open dentin tubules. It also investigates the chemical composition of residues after canal irrigation with a 1% peracetic acid solution (PA) at low or high concentration of hydrogen peroxide during the preparation of intracanal fiber posts. After filling the root canals of 40 mandibular incisors, a rotary instrument was used for intracanal preparation to place fiber posts. The teeth were divided into 4 groups (n=10) according to the post space irrigation protocol as follows: CG (control): distilled water; NA (NaOCl): 2.5% sodium hypochlorite; LH: PA with low concentration of hydrogen peroxide; and HH: PA with high concentrations of hydrogen peroxide. After irrigation, the teeth were sectioned, and the intracanal dentin surface was subjected to analysis using energy dispersive spectroscopy to evaluate chemical composition and to scanning electron microscopy (×500) to evaluate the presence of the smear layer. The number of open dentin tubules was measured by scanning electron microscopy analysis (×2000) using photo-editing software. ANOVA and the Tukey test (α=.05) were used to evaluate the data, except for the presence of a smear layer, for which the Kruskal-Wallis and Dunn tests were used (α=.05). The highest concentrations of oxygen in the dentin residues were detected in LH and HH (P<.05); CG and NA showed similar oxygen concentrations (P>.05). NA had a higher concentration of chlorine (P<.05), whereas LH had a lower amount of smear layer and a larger number of open dentin tubules than the other groups (P<.05). These were equivalent to each other (P>.05), except for HH, which also had a larger number of open dentin tubules than CG and NA (P<.05). PA 1% with a low concentration of hydrogen peroxide yielded a lower amount of smear layer and a larger number of open dentin tubules in the dentin of the post space when compared with PA 1% with a high concentration of hydrogen peroxide, despite maintaining a similar oxygen concentration in these dentin residues. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  8. Disinfection of foot-and-mouth disease and African swine fever viruses with citric acid and sodium hypochlorite on birch wood carriers

    USDA-ARS?s Scientific Manuscript database

    Transboundary animal disease viruses such as foot-and-mouth disease virus (FMDV) and African swine fever virus (ASFV) are highly contagious and cause severe morbidity and mortality in livestock. Proper disinfection during an outbreak can help prevent virus spread and will shorten the time for contam...

  9. Response surface model for the reduction of Salmonella biofilm on stainless steel with lactic acid, ethanol and chlorine as controlling factors

    USDA-ARS?s Scientific Manuscript database

    Bacterial colonization and biofilm formation on food contact surfaces can be sources of contamination of processed foods and poses a serious threat to health. Since chlorine- or ethanol-based disinfection is commonly used in the food industry and kitchens, a disinfectant containing chlorine (Cl), et...

  10. A comparison of disinfection by-products formation during sequential or simultaneous disinfection of surface waters with chlorine dioxide and chlor(am)ine.

    PubMed

    Shi, Yanwei; Ling, Wencui; Qiang, Zhimin

    2013-01-01

    The effect of chlorine dioxide (ClO2) oxidation on the formation of disinfection by-products (DBPs) during sequential (ClO2 pre-oxidation for 30 min) and simultaneous disinfection processes with free chlorine (FC) or monochloramine (MCA) was investigated. The formation of DBPs from synthetic humic acid (HA) water and three natural surface waters containing low bromide levels (11-27 microg/L) was comparatively examined in the FC-based (single FC, sequential ClO2-FC, and simultaneous ClO2/FC) and MCA-based (single MCA, ClO2-MCA, and ClO2/MCA) disinfection processes. The results showed that much more DBPs were formed from the synthetic HA water than from the three natural surface waters with comparative levels of dissolved organic carbon. In the FC-based processes, ClO2 oxidation could reduce trihalomethanes (THMs) by 27-35% and haloacetic acids (HAAs) by 14-22% in the three natural surface waters, but increased THMs by 19% and HAAs by 31% in the synthetic HA water after an FC contact time of 48 h. In the MCA-based processes, similar trends were observed although DBPs were produced at a much lower level. There was an insignificant difference in DBPs formation between the sequential and simultaneous processes. The presence of a high level of bromide (320 microg/L) remarkably promoted the DBPs formation in the FC-based processes. Therefore, the simultaneous disinfection process of ClO2/MCA is recommended particularly for waters with a high bromide level.

  11. Mechanisms of Human Adenovirus Inactivation by Sunlight and UVC Light as Examined by Quantitative PCR and Quantitative Proteomics

    PubMed Central

    Bosshard, Franziska; Armand, Florence; Hamelin, Romain

    2013-01-01

    Human adenoviruses (HAdV) are important pathogens in both industrialized and developing nations. HAdV has been shown to be relatively resistant to monochromatic UVC light. Polychromatic UVC light, in contrast, is a more effective means of disinfection, presumably due to the involvement of viral proteins in the inactivation mechanism. Solar disinfection of HAdV, finally, is only poorly understood. In this paper, the kinetics and mechanism of HAdV inactivation by UVC light and direct and indirect solar disinfection are elucidated. PCR and mass spectrometry were employed to quantify the extent of genome and protein degradation and to localize the affected regions in the HAdV proteins. For this purpose, we used for the first time an approach involving stable isotope labeling by amino acids in cell culture (SILAC) of a human virus. Inactivation by UVC light and the full sunlight spectrum were found to efficiently inactivate HAdV, whereas UVA-visible light only caused inactivation in the presence of external sensitizers (indirect solar disinfection). Genome damage was significant for UVC but was less important for solar disinfection. In contrast, indirect solar disinfection exhibited extensive protein degradation. In particular, the fiber protein and the amino acids responsible for host binding within the fiber protein were shown to degrade. In addition, the central domain of the penton protein was damaged, which may inhibit interactions with the fiber protein and lead to a disruption of the initial stages of infection. Damage to the hexon protein, however, appeared to affect only regions not directly involved in the infectious cycle. PMID:23241978

  12. Disinfective process of strongly acidic electrolyzed product of sodium chloride solution against Mycobacteria.

    PubMed

    Yamamoto, Tomoyo Matsushita; Nakano, Takashi; Yamaguchi, Masaki; Shimizu, Mitsuhide; Wu, Hong; Aoki, Hiroaki; Ota, Rie; Kobayashi, Toyohide; Sano, Kouichi

    2012-12-01

    Electrolyzed acid water (EAW) has been studied for its disinfective potential against pathogenic microbes; however, the bactericidal process against Mycobacteria has not been clearly presented. In this study, to clarify the disinfective process against Mycobacteria, EAW-treated bacteria were examined against laboratory strains of Mycobacterium bovis (M. bovis), Mycobacterium smegmatis (M. smegmatis), and Mycobacterium terrae (M. terrae) by recovery culture and observation of morphology, enzymatic assay, and the detection of DNA. All experiments were performed with the use of EAW containing 30 ppm free chlorine that kills Mycobacteria, including three pathogenic clinical isolates of Mycobacterium tuberculosis (M. tuberculosis) and six isolates of other Mycobacteria, within 5 min. In morphology, the bacterial surface became rough, and a longitudinal concavity-like structure appeared. The intrabacterial enzyme of EAW-contacted bacteria was inactivated, but chromosomal DNA was not totally denatured. These results suggest that the bactericidal effect of EAW against Mycobacteria occurs by degradation of the cell wall, followed by denaturation of cytoplasmic proteins, but degeneration of the nucleic acid is not always necessary.

  13. Notes from the Field: Respiratory Symptoms and Skin Irritation Among Hospital Workers Using a New Disinfection Product - Pennsylvania, 2015.

    PubMed

    Hawley, Brie; Casey, Megan L; Cox-Ganser, Jean M; Edwards, Nicole; Fedan, Kathleen B; Cummings, Kristin J

    2016-04-22

    In March 2014, a new disinfection product, consisting of hydrogen peroxide, peroxyacetic acid, and acetic acid, was introduced at a Pennsylvania hospital to aid in the control of health care-associated infections. The product is an Environmental Protection Agency-registered non-bleach sporicide advertised as a one-step cleaner, disinfectant, and deodorizer. According to the manufacturer's safety data sheet, the product requires no personal protective equipment when it is diluted with water by an automated dispenser before use. On January 30, 2015, CDC's National Institute for Occupational Health (NIOSH) received a confidential employee request to conduct a health hazard evaluation at the hospital. The request cited concerns about exposure of hospital environmental services staff members to the product and reported symptoms among persons who had used the product that included eye and nasal problems, asthma-like symptoms, shortness of breath, skin problems, wheeze, chest tightness, and cough.

  14. Kinetics and Mechanism of Bioactivation via S-Oxygenation of Anti-Tubercular Agent Ethionamide by Peracetic Acid.

    PubMed

    Chipiso, Kudzanai; Logan, Isabelle E; Eskew, Matthew W; Omondi, Benard; Simoyi, Reuben H

    2016-10-11

    The kinetics and mechanism of the oxidation of the important antitubercular agent, ethionamide, ETA (2-ethylthioisonicotinamide), by peracetic acid (PAA) have been studied. It is effectively a biphasic reaction with an initial rapid first phase of the reaction which is over in about 5 s and a second slower phase of the reaction which can run up to an hour. The first phase involves the addition of a single oxygen atom to ethionamide to form the S-oxide. The second phase involves further oxidation of the S-oxide to desulfurization of ETA to give 2-ethylisonicotinamide. In contrast to the stability of most organosulfur compounds, the S-oxide of ETA is relatively stable and can be isolated. In conditions of excess ETA, the stoichiometry of the reaction was strictly 1:1: CH 3 CO 3 H + Et(C 5 H 4 )C(═S)NH 2 → CH 3 CO 2 H + Et(C 5 H 4 )C(═NH)SOH. In this oxidation, it was apparent that only the sulfur center was the reactive site. Though ETA was ultimately desulfurized, only the S-oxide was stable. Electrospray ionization (ESI) spectral analysis did not detect any substantial formation of the sulfinic and sulfonic acids. This suggests that cleavage of the carbon-sulfur bond occurs at the sulfenic acid stage, resulting in the formation of an unstable sulfur species that can react further to form more stable sulfur species. In this oxidation, no sulfate formation was observed. ESI spectral analysis data showed a final sulfur species in the form of a dimeric sulfur monoxide species, H 3 S 2 O 2 . We derived a bimolecular rate constant for the formation of the S-oxide of (3.08 ± 0.72) × 10 2 M -1 s -1 . Oxidation of the S-oxide further to give 2-ethylisonicotinamide gave zero order kinetics.

  15. Determination of exogenous epigallocatechin gallate peracetate in mouse plasma using liquid chromatography with quadrupole time-of-flight mass spectrometry.

    PubMed

    Chu, Kai On; Man, Gene Chi Wai; Chan, Kwok Ping; Chu, Ching Yan; Chan, Tak Hang; Pang, Chi Pui; Wang, Chi Chiu

    2014-12-01

    A robust method for the quantitation of epigallocatechin gallate peracetate in plasma for pharmacokinetic studies is lacking. We have developed a validated method to quantify this compound using liquid chromatography with quadrupole time-of-flight mass spectrometry with isopropanol and tert-butyl methyl ether (3:10) extraction and thin-layer chromatography purification. The epigallocatechin gallate peracetate-1-(13) C8 isotope was used as an internal standard. The linear range (r(2) > 0.9950) was from 0.05 to 100.00 μg/mL. The lower limit of quantification of the method was 0.05 μg/mL. Reproducibility, coefficient of variation, was between 0.7 and 12.6% (n = 6), accuracy between 83.7 and 104.6% (n = 5), and recovery ranged from 82.4 to 109.0% (n = 4). Ion suppression was approximately 40%. No mass spectral peaks were found to interfere between the standard and internal standard or the blank plasma extracts. Epigallocatechin gallate peracetate in plasma was stably stored at -80°C over three months even after three freeze-thaw cycles. Extracts were stable in the sampler at 4°C for over 48 h. Plasma levels were maintained at 1.36 μg/mL for 360 min after intraorbital intravenous injection at 50 mg/kg in mice. This method can be used to reliably measure epigallocatechin gallate peracetate in plasma for pharmacokinetic studies. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. FORMATION AND ENANTIOSELECTIVE BIODEGRADATION OF THE ENANTIOMERS OF BROMOCHLOROACETIC ACID

    EPA Science Inventory

    Bromochloroacetic acid (BCAA) is formed by chlorination of drinking waters containing naturally occurring bromide. This haloacetic acid is a concern to public health because of suspected carcinogenicity and toxicity, and is a potential target of disinfectant byproduct regulations...

  17. Human cell toxicogenomic analysis linking reactive oxygen species to the toxicity of monohaloacetic acid drinking water disinfection byproducts.

    PubMed

    Pals, Justin; Attene-Ramos, Matias S; Xia, Menghang; Wagner, Elizabeth D; Plewa, Michael J

    2013-01-01

    Chronic exposure to drinking water disinfection byproducts has been linked to adverse health risks. The monohaloacetic acids (monoHAAs) are generated as byproducts during the disinfection of drinking water and are cytotoxic, genotoxic, mutagenic, and teratogenic. Iodoacetic acid toxicity was mitigated by antioxidants, suggesting the involvement of oxidative stress. Other monoHAAs may share a similar mode of action. Each monoHAA generated a significant concentration-response increase in the expression of a β-lactamase reporter under the control of the antioxidant response element (ARE). The monoHAAs generated oxidative stress with a rank order of iodoacetic acid (IAA) > bromoacetic acid (BAA) ≫ chloroacetic acid (CAA); this rank order was observed with other toxicological end points. Toxicogenomic analysis was conducted with a nontransformed human intestinal epithelial cell line (FHs 74 Int). Exposure to the monoHAAs altered the transcription levels of multiple oxidative stress responsive genes, indicating that each exposure generated oxidative stress. The transcriptome profiles showed an increase in thioredoxin reductase 1 (TXNRD1) and sulfiredoxin (SRXN1), suggesting peroxiredoxin proteins had been oxidized during monoHAA exposures. Three possible sources of reactive oxygen species were identified, the hypohalous acid generating peroxidase enzymes lactoperoxidase (LPO) and myeloperoxidase (MPO), nicotinamide adenine dinucleotide phosphate (NADPH)-dependent oxidase 5 (NOX5), and PTGS2 (COX-2) mediated arachidonic acid metabolism. Each monoHAA exposure caused an increase in COX-2 mRNA levels. These data provide a functional association between monoHAA exposure and adverse health outcomes such as oxidative stress, inflammation, and cancer.

  18. Performance of the full-scale biological nutrient removal plant at Noosa in Queensland, Australia: nutrient removal and disinfection.

    PubMed

    Urbain, V; Wright, P; Thomas, M

    2001-01-01

    Stringent effluent quality guidelines are progressively implemented in coastal and sensitive areas in Australia. Biological Nutrient Removal (BNR) plants are becoming a standard often including a tertiary treatment for disinfection. The BNR plant in Noosa - Queensland is designed to produce a treated effluent with less than 5 mg/l of BOD5, 5 mg/l of total nitrogen, 1 mg/l of total phosphorus, 5 mg/l of suspended solids and total coliforms of less than 10/100 ml. A flexible multi-stage biological process with a prefermentation stage, followed by sand filtration and UV disinfection was implemented to achieve this level of treatment. Acetic acid is added for phosphorus removal because: i) the volatile fatty acids (VFA) concentration in raw wastewater varies a lot, and ii) the prefermenter had to be turned off due to odor problems on the primary sedimentation tanks. An endogenous anoxic zone was added to the process to further reduce the nitrate concentration. This resulted in some secondary P-release events, a situation that happens when low nitrate and low phosphorus objectives are targeted. Long-term performance data and specific results on nitrogen removal and disinfection are presented in this paper.

  19. MICROARRAY ANALYSIS OF DICHLOROACETIC ACID-INDUCED CHANGES IN GENE EXPRESSION

    EPA Science Inventory


    MICROARRAY ANALYSIS OF DICHLOROACETIC ACID-INDUCED CHANGES IN GENE EXPRESSION

    Dichloroacetic acid (DCA) is a major by-product of water disinfection by chlorination. Several studies have demonstrated the hepatocarcinogenicity of DCA in rodents when administered in dri...

  20. Tumorigenic effects of dichloroacetic acid in female F344 rats

    EPA Science Inventory

    Introduction: Dichloroacetic acid (DCA) is a halogenated organic acid produced during oxidant disinfection of drinking water. Prior studies indicate that DCA may increase liver tumors in mice. Here we evaluated the hepatic tumorigenicity of DCA in female rats when given alone ...

  1. Molecular weight profiles of proanthocyanidin polymers

    Treesearch

    Vincent M. Williams; Lawrence J. Porter; Richard W. Hemingway

    1983-01-01

    The MW profiles of proanthocyanidin polymers (condensed tannins) from 32 samples representing a wide range of plant tissues of many different species have been obtained by gel permeation chromatography of the peracetate derivatives. The tannins vary widely in MW, with M values for the peracetates in the range 1600-5500. The MW profiles vary greatly from those with...

  2. Detection of genotoxic effects of drinking water disinfection by-products using Vicia faba bioassay.

    PubMed

    Hu, Yu; Tan, Li; Zhang, Shao-Hui; Zuo, Yu-Ting; Han, Xue; Liu, Na; Lu, Wen-Qing; Liu, Ai-Lin

    2017-01-01

    Plant-based bioassays have gained wide use among the toxicological and/or ecotoxicological assessment procedures because of their simplicity, sensitivity, low cost, and reliability. The present study describes the use of Vicia faba (V. faba) micronucleus (MN) test and V. faba comet assay in the evaluation of the genotoxic potential of disinfection by-products (DBPs) commonly found in chlorine-disinfected drinking water. Five haloacetic acids and three halogenated acetonitriles were chosen as representatives of DBPs in this study because they are of potentially great public health risk. Results of the MN test indicated that monochloroacetic acid (MCA), monobromoacetic acid (MBA), dichloroacetic acid (DCA), dibromoacetic acid (DBA), trichloroacetic acid (TCA), and trichloroacetonitrile (TCAN) caused a statistically significant increase in MN frequency in V. faba root tip cells. However, no genotoxic response was observed for dichloroacetonitrile (DCAN) and dibromoacetonitrile (DBAN). Results of the comet assay showed that all tested DBPs induced a statistically significant increase in genomic DNA damage to V. faba root tip cells. On considering the capacity to detect genomic damage of a different nature, we suggest that a combination of V. faba MN test and V. faba comet assay is a useful tool for the detection of genotoxic effects of DBPs. It is worthy of assessing the feasibility of using V. faba comet assay combined with V. faba MN test to screen for the genotoxic activity of chlorinated drinking water in future work.

  3. Characterization of dissolved organic matter from surface waters with low to high dissolved organic carbon and the related disinfection byproduct formation potential.

    PubMed

    Li, Angzhen; Zhao, Xu; Mao, Ran; Liu, Huijuan; Qu, Jiuhui

    2014-04-30

    In this study, the disinfection byproduct formation potential (DBPFP) of three surface waters with the dissolved organic carbon (DOC) content of 2.5, 5.2, and 7.9mg/L was investigated. The formation and distribution of trihalomethanes and haloacetic acids were evaluated. Samples collected from three surface waters in China were fractionated based on molecular weight and hydrophobicity. The raw water containing more hydrophobic (Ho) fraction exhibited higher formation potentials of haloacetic acid and trihalomethane. The DBPFP of the surface waters did not correlate with the DOC value. The values of DBPFP per DOC were correlated with the specific ultraviolet absorbance (SUVA) for Ho and Hi fractions. The obtained results suggested that SUVA cannot reveal the ability of reactive sites to form disinfection byproducts for waters with few aromatic structures. Combined with the analysis of FTIR and nuclear magnetic resonance spectra of the raw waters and the corresponding fractions, it was concluded that the Ho fraction with phenolic hydroxyl and conjugated double bonds was responsible for the production of trichloromethanes and trichloroacetic acids. The Hi fraction with amino and carboxyl groups had the potential to form dichloroacetic acids and chlorinated trihalomethanes. Copyright © 2014. Published by Elsevier B.V.

  4. Enhancement effects of ultrasound on secondary wastewater effluent disinfection by sodium hypochlorite and disinfection by-products analysis.

    PubMed

    Zhou, Xiaoqin; Zhao, Junyuan; Li, Zifu; Song, Jianing; Li, Xueying; Yang, Xin; Wang, Dongling

    2016-03-01

    Since fecal coliforms was introduced as a standard indicator of pollutants in effluents of municipal wastewater treatment plants in China in 2003, chlorine had been widely used in many wastewater treatment plants. However, concerns about the disinfection by-products (DBPs) of chlorine have been increasing. One of the effective way to reduce the production of DBPs is to reduce the effective chlorine dosage by improving the utilization rate of disinfectant. Ultrasound (US) is proved to be effective in wastewater treatment for its multiple chemical and physical effects produced by cavitation, which could favor the disinfection process accordingly. For the purpose of improving disinfection efficiency with the help of US, following points are addressed in the current study: (1) investigate the enhancement effects of US on the disinfection efficiency of sodium hypochlorite (NaClO) for real secondary effluents of municipal wastewater treatment plants; (2) evaluate the possibility of using US specific energy consumption (kJ/L) as an parameter for disinfection efficiency evaluation; and (3) quantify the reduction in chlorine-DBPs through US application. Results demonstrated that sonication could reduce two-thirds (US pretreatment) or one-third (simultaneous US and NaClO disinfection) of the required concentrations of NaClO (available chlorine) for 4 log reduction of fecal coliforms, which could meet the Class 1A (fecal coliforms less than 1000 CFU/L) discharge standard of China. In addition, US pretreatment with NaClO disinfection performed better enhancement in disinfection efficiency compared with simultaneous US and NaClO disinfection. Furthermore, analysis on DBPs showed that US application as pretreatment could obviously reduce the contents of trichloromethane (TCM) and trichloroacetic acid (TCAA) by more than 85% and 50%, respectively, compared with NaClO disinfection alone for the same disinfection efficiency. Meanwhile, the experimental results also showed that the disinfection efficiency and DBPs concentration were only slightly affected under a constant US specific energy consumption, although input power density and irradiation time changed, indicating that specific energy consumption (kJ/L) could be considered as a better control parameter for disinfection efficiency evaluation. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Induction of Fatty Acid Composition Modifications and Tolerance to Biocides in Salmonella enterica Serovar Typhimurium by Plant-Derived Terpenes▿

    PubMed Central

    Dubois-Brissonnet, Florence; Naïtali, Murielle; Mafu, Akier Assanta; Briandet, Romain

    2011-01-01

    To enhance food safety and stability, the food industry tends to use natural antimicrobials such as plant-derived compounds as an attractive alternative to chemical preservatives. Nonetheless, caution must be exercised in light of the potential for bacterial adaptation to these molecules, a phenomenon previously observed with other antimicrobials. The aim of this study was to characterize the adaptation of Salmonella enterica serovar Typhimurium to sublethal concentrations of four terpenes extracted from aromatic plants: thymol, carvacrol, citral, and eugenol, or combinations thereof. Bacterial adaptation in these conditions was demonstrated by changes in membrane fatty acid composition showing (i) limitation of the cyclization of unsaturated fatty acids to cyclopropane fatty acids when cells entered the stationary phase and (ii) bacterial membrane saturation. Furthermore, we demonstrated an increased cell resistance to the bactericidal activity of two biocides (peracetic acid and didecyl dimethyl ammonium bromide). The implications of membrane modifications in terms of hindering the penetration of antimicrobials through the bacterial membrane are discussed. PMID:21131520

  6. HALOACETIC ACIDS PERTURB PROTEIN PHOSPHORYLATION IN MOUSE EMBRYOS IN VITRO

    EPA Science Inventory

    HALOACETIC ACIDS PERTURB PROTEIN PHOSPHORYLATION IN MOUSE EMBRYOS IN VITRO. MR Blanton and ES Hunter. Reproductive Toxicology Division, NHEERL, ORD, US EPA, RTP, NC, USA.
    Sponsor: JM Rogers.
    Haloacetic Acids (HAAs) formed during the disinfection process are present in drin...

  7. BROMOCHLORO-HALOACETIC ACIDS: EFFECTS ON MOUSE EMBRYOS IN VITRO AND QSAR CONSIDERATIONS

    EPA Science Inventory

    The haloacetic acids (HAA) are a family of chemicals that are drinking water disinfection byproducts. We previously reported that bromo- and chloro-acetic acids altered embryonic development when mouse conceptuses were directly exposed to these xenobiotics in whole embryo culture...

  8. BROMOCHLOROACETIC ACID EXERTS QUALITATIVE EFFECTS ON RAT SPERM: IMPLICATIONS FOR A NOVEL BIOMARKER

    EPA Science Inventory

    ABSTRACT
    Disubstituted haloacid by-products of drinking water disinfection such as dibromoacetic acid and dichloroacetic acid have been shown to perturb spermatogenesis and fertility in adult male rats. In the present study we sought to establish whether equimolar exposur...

  9. 40 CFR 141.64 - Maximum contaminant levels for disinfection byproducts.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... trihalomethanes (TTHM) and Haloacetic acids (five) (HAA5) Enhanced coagulation or enhanced softening or GAC10... Haloacetic acids (five) (HAA5) Enhanced coagulation or enhanced softening, plus GAC10; or nanofiltration with...

  10. 40 CFR 141.64 - Maximum contaminant levels for disinfection byproducts.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... trihalomethanes (TTHM) and Haloacetic acids (five) (HAA5) Enhanced coagulation or enhanced softening or GAC10... Haloacetic acids (five) (HAA5) Enhanced coagulation or enhanced softening, plus GAC10; or nanofiltration with...

  11. 40 CFR 141.64 - Maximum contaminant levels for disinfection byproducts.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... trihalomethanes (TTHM) and Haloacetic acids (five) (HAA5) Enhanced coagulation or enhanced softening or GAC10... Haloacetic acids (five) (HAA5) Enhanced coagulation or enhanced softening, plus GAC10; or nanofiltration with...

  12. 40 CFR 141.64 - Maximum contaminant levels for disinfection byproducts.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... trihalomethanes (TTHM) and Haloacetic acids (five) (HAA5) Enhanced coagulation or enhanced softening or GAC10... Haloacetic acids (five) (HAA5) Enhanced coagulation or enhanced softening, plus GAC10; or nanofiltration with...

  13. Efficacy of Peracetic Acid in Inactivating Foodborne Pathogens on Fresh Produce Surface.

    PubMed

    Singh, Prashant; Hung, Yen-Con; Qi, Hang

    2018-02-01

    Washing treatment with effective sanitizer is one of the critical steps in ensuring fresh produce safety. This study was to evaluate the efficacy of peracetic acid (PAA; VigorOx® 15 F&V), chlorine-based sanitizers (acidic electrolyzed water [AEO], near neutral electrolyzed water and bleach), lactic acid, and deionized (DI) water to reduce Escherichia coli O157:H7, Listeria monocytogenes, and Salmonella Typhimurium DT104 from fresh produce surfaces. A 5-strain cocktail of E. coli O157:H7, L. monocytogenes, and S. Typhimurium DT104 was separately prepared and used for surface inoculation on produce samples (E. coli O157:H7 on romaine lettuce, lemons, tomatoes, and blueberries; L. monocytogenes on romaine lettuce and cantaloupe; S. Typhimurium DT104 on lemons, tomatoes, cantaloupe, and blueberries). PAA at 45, 85, and 100 mg/L; AEO, NNEO, and bleach at 100 mg/L of free chlorine; lactic acid at 2%; and DI water were used for washing inoculated produce in an automated produce washer for 5 min. In general, PAA at 100 mg/L achieved the highest microbial inactivation of E. coli O157:H7 (lettuce, lemon, tomato, and blueberry at 2.2, 5.7, 5.5, and 6.7 log CFU/g, respectively), S. Typhimurium DT104 (lemon, tomato, cantaloupe, blueberry at 5.4, 6.8, 4.5, and 5.9 log CFU/g, respectively), and L. monocytogenes (lettuce and cantaloupe at 2.4 and 4.4 log CFU/g, respectively). Efficacy of sanitizers on produce with coarse surface (for example, lettuce and cantaloupe) was lower than produce with smooth texture (lemon, tomato, and blueberry). Cross-contamination of E. coli O157:H7 among romaine lettuce heads during simulated retail crisping process was greatly reduced by the application of PAA and NNEO. NNEO and PAA showed high efficacy in foodborne pathogen removal from fresh produce. Produce surface texture plays an important role in pathogen removal. NNEO and PAA effectively prevented cross-contamination during the crisping process. © 2018 Institute of Food Technologists®.

  14. Surfactant-enhanced disinfection of the human norovirus surrogate, Tulane virus, with organic acids and surfactant

    USDA-ARS?s Scientific Manuscript database

    Combination treatments of surfactants and phenolic or short-chained organic acids (SCOA) may act synergistically or additively as sanitizers to inactive foodborne viruses and prevent outbreaks. The purpose of this study was to investigate the effect of gallic acid (GA), tannic acid (TA), p-coumaric ...

  15. Alternative sanitization methods for minimally processed lettuce in comparison to sodium hypochlorite

    PubMed Central

    Bachelli, Mara Lígia Biazotto; Amaral, Rívia Darla Álvares; Benedetti, Benedito Carlos

    2013-01-01

    Lettuce is a leafy vegetable widely used in industry for minimally processed products, in which the step of sanitization is the crucial moment for ensuring a safe food for consumption. Chlorinated compounds, mainly sodium hypochlorite, are the most used in Brazil, but the formation of trihalomethanes from this sanitizer is a drawback. Then, the search for alternative methods to sodium hypochlorite has been emerging as a matter of great interest. The suitability of chlorine dioxide (60 mg L−1/10 min), peracetic acid (100 mg L−1/15 min) and ozonated water (1.2 mg L−1 /1 min) as alternative sanitizers to sodium hypochlorite (150 mg L−1 free chlorine/15 min) were evaluated. Minimally processed lettuce washed with tap water for 1 min was used as a control. Microbiological analyses were performed in triplicate, before and after sanitization, and at 3, 6, 9 and 12 days of storage at 2 ± 1 °C with the product packaged on LDPE bags of 60 μm. It was evaluated total coliforms, Escherichia coli, Salmonella spp., psicrotrophic and mesophilic bacteria, yeasts and molds. All samples of minimally processed lettuce showed absence of E. coli and Salmonella spp. The treatments of chlorine dioxide, peracetic acid and ozonated water promoted reduction of 2.5, 1.1 and 0.7 log cycle, respectively, on count of microbial load of minimally processed product and can be used as substitutes for sodium hypochlorite. These alternative compounds promoted a shelf-life of six days to minimally processed lettuce, while the shelf-life with sodium hypochlorite was 12 days. PMID:24516433

  16. Alternative sanitization methods for minimally processed lettuce in comparison to sodium hypochlorite.

    PubMed

    Bachelli, Mara Lígia Biazotto; Amaral, Rívia Darla Álvares; Benedetti, Benedito Carlos

    2013-01-01

    Lettuce is a leafy vegetable widely used in industry for minimally processed products, in which the step of sanitization is the crucial moment for ensuring a safe food for consumption. Chlorinated compounds, mainly sodium hypochlorite, are the most used in Brazil, but the formation of trihalomethanes from this sanitizer is a drawback. Then, the search for alternative methods to sodium hypochlorite has been emerging as a matter of great interest. The suitability of chlorine dioxide (60 mg L(-1)/10 min), peracetic acid (100 mg L(-1)/15 min) and ozonated water (1.2 mg L(-1)/1 min) as alternative sanitizers to sodium hypochlorite (150 mg L(-1) free chlorine/15 min) were evaluated. Minimally processed lettuce washed with tap water for 1 min was used as a control. Microbiological analyses were performed in triplicate, before and after sanitization, and at 3, 6, 9 and 12 days of storage at 2 ± 1 °C with the product packaged on LDPE bags of 60 μm. It was evaluated total coliforms, Escherichia coli, Salmonella spp., psicrotrophic and mesophilic bacteria, yeasts and molds. All samples of minimally processed lettuce showed absence of E. coli and Salmonella spp. The treatments of chlorine dioxide, peracetic acid and ozonated water promoted reduction of 2.5, 1.1 and 0.7 log cycle, respectively, on count of microbial load of minimally processed product and can be used as substitutes for sodium hypochlorite. These alternative compounds promoted a shelf-life of six days to minimally processed lettuce, while the shelf-life with sodium hypochlorite was 12 days.

  17. The effect of peracetic acid on removing calcium hydroxide from the root canals.

    PubMed

    Sağsen, Burak; Ustün, Yakup; Aslan, Tuğrul; Canakçi, Burhan Can

    2012-09-01

    The goal of this study was to evaluate the efficiencies of different irrigation solutions in the removal of calcium hydroxide (CH). Forty-eight maxillary central incisor teeth were used. Root canals were prepared with the ProTaper system (Dentsply Maillefer, Baillagues, Switzerland). Five milliliters 2% NaOCl, 5 mL 17% EDTA, and 10 mL saline were used for final irrigation. The canals were filled with CH paste. Specimens were randomly divided into 4 experimental groups (n = 10) according to irrigation protocols. Positive and negative control groups (n = 4) were used. Group 1 used 2.5 mL 17% EDTA, group 2 used 2.5 mL 2.5% NaOCl + 2.5 mL 17% EDTA, group 3 used 2.5 mL 1% peracetic acid (PAA), and group 4 used 2.5 mL 0.5% PAA. The specimens were evaluated with scanning electron microscope analysis and scored. Kruskal-Wallis and Student Newman-Keuls post hoc tests were used for statistical analysis. In the apical thirds, 1% PAA was superior to the other groups (P < .05); however, there were no significant differences among the other groups (P > .05). In the middle thirds, no significant differences were found among the groups (P > .05). In the coronal thirds, 1% PAA was superior to the other groups. There were significant differences among all the other groups (P < .05). According to the findings of the present study, 1% PAA could be recommended for the removal of CH from the root canals. Crown Copyright © 2012. Published by Elsevier Inc. All rights reserved.

  18. Description and evaluation of a peracetic acid air sampling and analysis method.

    PubMed

    Nordling, John; Kinsky, Owen R; Osorio, Magdalena; Pechacek, Nathan

    2017-12-01

    Peracetic acid (PAA) is a corrosive chemical with a pungent odor, which is extensively used in occupational settings and causes various health hazards in exposed workers. Currently, there is no US government agency recommended method that could be applied universally for the sampling and analysis of PAA. Legacy methods for determining airborne PAA vapor levels frequently suffered from cross-reactivity with other chemicals, particularly hydrogen peroxide (H 2 O 2 ). Therefore, to remove the confounding factor of cross-reactivity, a new viable, sensitive method was developed for assessment of PAA exposure levels, based on the differential reaction kinetics of PAA with methyl p-tolylsulfide (MTS), relative to H 2 O 2 , to preferentially derive methyl p-tolysulfoxide (MTSO). By quantifying MTSO concentration produced in the liquid capture solution from an air sampler, using an internal standard, and utilizing the reaction stoichiometry of PAA and MTS, the original airborne concentration of PAA is determined. After refining this liquid trap high-performance liquid chromatography (HPLC) method in the laboratory, it was tested in five workplace settings where PAA products were used. PAA levels ranged from the detection limit of 0.013 parts per million (ppm) to 0.4 ppm. The results indicate a viable and potentially dependable method to assess the concentrations of PAA vapors under occupational exposure scenarios, though only a small number of field measurements were taken while field testing this method. However, the low limit of detection and precision offered by this method makes it a strong candidate for further testing and validation to expand the uses of this liquid trap HPLC method.

  19. Dialyzer Reuse with Peracetic Acid Does Not Impact Patient Mortality

    PubMed Central

    Bond, T. Christopher; Krishnan, Mahesh; Wilson, Steven M.; Mayne, Tracy

    2011-01-01

    Summary Background and objectives Numerous studies have shown the overall benefits of dialysis filter reuse, including superior biocompatibility and decreased nonbiodegradable medical waste generation, without increased risk of mortality. A recent study reported that dialyzer reprocessing was associated with decreased patient survival; however, it did not control for sources of potential confounding. We sought to determine the effect of dialyzer reprocessing with peracetic acid on patient mortality using contemporary outcomes data and rigorous analytical techniques. Design, setting, participants, & measurements We conducted a series of analyses of hemodialysis patients examining the effects of reuse on mortality using three techniques to control for potential confounding: instrumental variables, propensity-score matching, and time-dependent survival analysis. Results In the instrumental variables analysis, patients at high reuse centers had 16.2 versus 15.9 deaths/100 patient-years in nonreuse centers. In the propensity-score matched analysis, patients with reuse had a lower death rate per 100 patient-years than those without reuse (15.2 versus 15.5). The risk ratios for the time-dependent survival analyses were 0.993 (per percent of sessions with reuse) and 0.995 (per unit of last reuse), respectively. Over the study period, 13.8 million dialyzers were saved, representing 10,000 metric tons of medical waste. Conclusions Despite the large sample size, powered to detect miniscule effects, neither the instrumental variables nor propensity-matched analyses were statistically significant. The time-dependent survival analysis showed a protective effect of reuse. These data are consistent with the preponderance of evidence showing reuse limits medical waste generation without negatively affecting clinical outcomes. PMID:21566107

  20. A Cumulative Spore Killing Approach: Synergistic Sporicidal Activity of Dilute Peracetic Acid and Ethanol at Low pH Against Clostridium difficile and Bacillus subtilis Spores.

    PubMed

    Nerandzic, Michelle M; Sankar C, Thriveen; Setlow, Peter; Donskey, Curtis J

    2016-01-01

    Background.  Alcohol-based hand sanitizers are the primary method of hand hygiene in healthcare settings, but they lack activity against bacterial spores produced by pathogens such as Clostridium difficile and Bacillus anthracis. We previously demonstrated that acidification of ethanol induced rapid sporicidal activity, resulting in ethanol formulations with pH 1.5-2 that were as effective as soap and water washing in reducing levels of C difficile spores on hands. We hypothesized that the addition of dilute peracetic acid (PAA) to acidified ethanol would enhance sporicidal activity while allowing elevation of the pH to a level likely to be well tolerated on skin (ie, >3). Methods.  We tested the efficacy of acidified ethanol solutions alone or in combination with PAA against C difficile and Bacillus subtilis spores in vitro and against nontoxigenic C difficile spores on hands of volunteers. Results.  Acidification of ethanol induced rapid sporicidal activity against C difficile and to a lesser extent B subtilis. The addition of dilute PAA to acidified ethanol resulted in synergistic enhancement of sporicidal activity in a dose-dependent fashion in vitro. On hands, the addition of 1200-2000 ppm PAA enhanced the effectiveness of acidified ethanol formulations, resulting in formulations with pH >3 that were as effective as soap and water washing. Conclusions.  Acidification and the addition of dilute PAA induced rapid sporicidal activity in ethanol. Our findings suggest that it may be feasible to develop effective sporicidal ethanol formulations that are safe and tolerable on skin.

  1. Effective analysis of the use of peracetic acid after instrumentation of root canals contaminated with Enterococcus faecalis.

    PubMed

    Cord, Caroline Berwanger; Velasco, Rafael Vidal Cortez; Ribeiro Melo Lima, Laíla Fernanda; Rocha, Daniel Guimarães Pedro; da Silveira Bueno, Carlos Eduardo; Pinheiro, Sérgio Luiz

    2014-08-01

    The aim of this study was to evaluate the effectiveness of peracetic acid (PAA) in cleaning root canals contaminated with Enterococcus faecalis. Sixty first and second mandibular molars were used. Their mesiobuccal canals were prepared with the Reciproc System (VDW, Munich, Germany). The canals were irrigated with 10 mL saline during instrumentation. The teeth were randomly divided into 3 groups (n = 20), according to the irrigation solution to be used after instrumentation: group PAA (5 mL 1% PAA), group EDTA/sodium hypochlorite (NaOCl) (5 mL 17% EDTA followed by 5 mL 2.5% sodium hypochlorite), and group S (5 mL saline). Microbiological samples were collected before instrumentation and after final irrigation. Bacterial quantification was performed by counting the number of colony-forming units (CFUs/mL). The results were analyzed by the nonparametric Wilcoxon and Kruskal-Wallis tests. The 3 groups showed a significant reduction (P < .05) in CFUs/mL after final irrigation. PAA and NaOCl associated with EDTA produced a significantly higher reduction in CFUs/mL (P < .05) compared with saline. There was no statistically significant difference between PAA and EDTA + 2.5% NaOCl (P > .05). According to the results of the present study, the effectiveness of 1% PAA was similar to that of 17% EDTA + 2.5% NaOCl in cleaning curved root canals contaminated with E. faecalis. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  2. The microbial and quality properties of poultry carcasses treated with peracetic acid as an antimicrobial treatment.

    PubMed

    Bauermeister, L J; Bowers, J W J; Townsend, J C; McKee, S R

    2008-11-01

    Salmonella spp. and Campylobacter spp. continue to be prominent food safety concerns for the poultry industry and consumers alike. Peracetic acid (PAA) has been approved as an antimicrobial for use in poultry chillers. To validate its effectiveness, 100 poultry carcasses (per replication x 2) were inoculated with Salmonella (10(6) cfu) or Campylobacter (10(6) cfu) and were randomly allocated into chill water containing chlorine (0.003%) or PAA (0.0025%, 0.01%, or 0.02%). Results indicated that PAA concentrations as low as 0.0025% were effective in decreasing Salmonella spp., whereas PAA levels of 0.02% were effective in decreasing Campylobacter spp. when compared with the chlorine treatment. A sensory study was also conducted with another set of 500 carcasses (not inoculated). Birds were treated with water, chlorine (0.003%), or PAA (0.01%, 0.015%, or 0.02%). Sensory panels and microbial data were collected weekly on randomly sampled carcasses that were stored at 4 degrees C for 21 d. The PAA-treated carcasses at 0.015% and 0.02% had an extended shelf-life compared with those treated with water or chlorine. Specifically, on d 15, the only treatments that could be served to sensory panelists were the carcasses treated with 0.015% or 0.02% PAA. The carcasses treated with water, chlorine, or 0.01% PAA had off-colors, off-odors, and high microbial counts. These results suggest that PAA may be an effective antimicrobial when used in poultry chiller applications and greater levels (>or=0.015%) may extend product shelf-life.

  3. Effects of ethylenediaminetetraacetic, etidronic and peracetic acid irrigation on human root dentine and the smear layer.

    PubMed

    Lottanti, S; Gautschi, H; Sener, B; Zehnder, M

    2009-04-01

    To evaluate the effects of ethylenediaminetetraacetic (EDTA), etidronic (EA) and peracetic acid (PA) when used in conjunction with sodium hypochlorite (NaOCl) as root canal irrigants on calcium eluted from canals, smear layer, and root dentine demineralization after instrumentation/irrigation. Single-rooted human premolars were irrigated as follows (n = 12 per group): (1) 1% NaOCl during instrumentation, deionized water after instrumentation, (2) 1% NaOCl during, 17% EDTA after instrumentation, (3) a 1 : 1-mixture of 2% NaOCl and 18% EA during and after instrumentation, and (4) 1% NaOCl during, 2.25% PA after instrumentation. Irrigant volumes and contact times were 10 mL/15 min during and 5 mL/3 min after instrumentation. The evaluated outcomes were eluted calcium by atomic absorption spectroscopy, smear-covered areas by scanning electron microscopy in secondary electron mode and apparent canal wall decalcifications on root transsections in backscatter mode. For the smear layer analysis, sclerotic dentine was taken into consideration. Results were compared using appropriate parametric and nonparametric tests, alpha = 0.05. The statistical comparison of the protocols regarding calcium elution revealed that protocol (1) yielded less calcium than (3), which yielded less than protocols (2) and (4). Most of the instrumented canal walls treated with one of the decalcifying agents were free of smear layer. Protocols (1) and (3) caused no decalcification of root dentine, whilst (2) and (4) showed substance typical demineralization patterns. The decalcifying agents under investigation were all able to remove or prevent a smear layer. However, they eroded the dentine wall differently.

  4. Reduction of disinfection by-product precursors in reservoir water by coagulation and ultrafiltration.

    PubMed

    Wang, Feng; Gao, Baoyu; Ma, Defang; Yue, Qinyan; Li, Ruihua; Wang, Qianwen

    2016-11-01

    In this study, reservoir water intended for drinking water supply was treated by (i) ultrafiltration (UF) (ii) coagulation (CW) (iii) coagulation combined with ultrafiltration (CW-UF). To probe the influences of three treatment processes on disinfection byproduct (DBP) precursors in source water, the changes of dissolved organic matter (DOM) amounts and physicochemical properties, and disinfection byproduct (DBP) formation characteristics during chlorine disinfection were investigated. Both carbonaceous DBP (C-DBP) and nitrogenous DBP (N-DBP) formation and speciation were analyzed. The influence of chlorine dose, contact time on DBP formation and speciation were also studied to optimize the disinfection conditions to minimize the DBP formation. Compared with UF and CW alone, CW-UF improved the dissolved organic carbon (DOC) removal from about 20 % to 59 %. The three-dimensional excitation and emission matrix (3DEEM) fluorescence spectroscopy analysis showed that CW-UF had high removal efficiency in microbial products (Region IV), fulvic acid-like (Region III) and humic acid-like (Region V). The total C-DBP was determined by the formation of trihalomethanes and trichloromethane was the most abundant species (40 %). The most abundant N-DBP species was dichloroacetonitrile (32.5 %), followed by trichloroactetonitrile. CW-UF effectively reduced the risk of DBPs in drinking water supply by reducing 30.8 % and 16.9 % DBPs formation potential compared with UF and CW alone. Increasing contact time improved the yields of both C-DBPs and N-DBPs. Chlorine dosage had slight influence on DBP yield in this study.

  5. EARLY GENE EXPRESSION CHANGES IN THE LIVERS OF MICE EXPOSED TO DICHLOROACETIC ACID

    EPA Science Inventory

    EARLY GENE EXPRESSION CHANGES IN THE LIVERS OF MICE EXPOSED TO DICHLOROACETIC ACID

    Dichloroacetic acid (DCA) is a major by-product of water disinfection by chlorination. Several studies have shown that DCA induces liver tumors in rodents when administered in drinking wate...

  6. DICHLOROACETIC ACID (DCA) INHIBITS PROLIFERATION AND APOPTOSIS IN NORMAL HEPATOCYTES OF MALE F344 RATS

    EPA Science Inventory

    Dichloroacetic acid (DCA} inhibits proliferation and apoptosis in nonnal hepatocytes of
    male F344 rats.

    Large segments of the population are chronically exposed to dichloroacetic acid (DCA}: DCA is a by product of the chlorine disinfection of drinking water, a metab...

  7. A MULTISTAGE BIOLOGICALLY BASED MODEL FOR MOUSE LIVER TUMORS RESULTING FROM EXPOSURE TO DICHLOROACETIC ACID

    EPA Science Inventory

    Dichloroacetic Acid (DCA) is a major byproduct of the chlorine disinfection of humic acid containing drinking water sources. It is a hepatocarcinogen in mice and rats at exposure concentrations in drinking water that are at least 4 orders of magnitude above the concentrations in ...

  8. DIBROMOACETIC ACID-INDUCED ELEVATIONS OF ESTRADIOL IN THE CYCLING AND OVARIECTOMOZED/ESTRADIOL-IMPLANTED FEMALE RAT

    EPA Science Inventory

    Goldman, JM and Murr, AS. Dibromoacetic Acid-induced Elevations of Estradiol in Both Cycling and Ovariectomized / Estradiol-implanted Female Rats

    ABSTRACT
    Haloacetic acids are one of the principal classes of disinfection by-products generated by the chlorination of mun...

  9. EARLY GENE EXPRESSION CHANGES IN THE LIVERS OF MICE EXPOSED TO DICHOLORACETC ACID

    EPA Science Inventory

    EARLY GENE EXPRESSION CHANGES IN THE LIVERS OF MICE EXPOSED TO DICHLOROACETIC ACID

    Dichloroacetic acid COCA) is a major by-product ofwater disinfection by cWorination. Several
    studies have shown that DCA induces liver tumors in rodents when administered in drinkmg wate...

  10. Prediction of the developmental toxicity hazard potential of halogenated drinking water disinfection by-products tested by the in vitro hydra assay

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fu, L.J.; Johnson, E.M.; Newman, L.M.

    A series of seven randomly selected potential halogenated water disinfection by-products were evaluated in vitro by the hydra assay to determine their developmental toxicity hazard potential. For six of the chemicals tested by this assay (dibromoacetonitrile; trichloroacetonitrile; 2-chlorophenol; 2,4,6-trichlorophenol; trichloroacetic acid; dichloroacetone) it was predicted that they would be generally equally toxic to both adult and embryonic mammals when studied by means of standard developmental toxicity teratology tests. However, the potential water disinfection by-product chloroacetic acid (CA) was determined to be over eight times more toxic to the embryonic developmental portion of the assay than it was to the adults.more » Because of this potential selectivity, CA is a high-priority item for developmental toxicity tests in pregnant mammals to confirm or refute its apparent unique developmental hazard potential and/or to establish a NOAEL by the route of most likely human exposure.« less

  11. Desulfurization of Saudi Arabian crudes by oxidation-extraction method.

    PubMed

    Al Otaibi, Raja L; Liu, Dong; Hou, Xulian; Song, Linhua; Li, Qingyin; Li, Mengfei; Almigrin, Hamid O; Yan, Zifeng

    The oxidation-extraction desulfurization of Saudi Arabian crudes was conducted with hydrogen peroxide-acetic acid oxidation system. The selection of extractant, the optimization of oxidation-extraction conditions, and the exploration of desulfurization mechanism were studied. As DMF was used as the extractant, the optimal desulfurization rate of 35.11 % and oil recovery of 95 % were obtained at 70 °C with the molar ratio of peracetic acid to sulfur of 8:1, the molar ratio of acetic acid to hydrogen peroxide of 2:1 and the volume ratio of extractant to oil of 1:1. The desulfurization effect of different fractions in the treated Saudi Arabian crudes was found to obey the following order: gasoline-diesel fraction >VGO fraction >VR fraction, due to different types and structures of sulfur compounds. The oil quality was less affected and most sulfides were mainly extracted via DMF.

  12. Human cell toxicogenomic analysis links reactive oxygen species to the toxicity of monohaloacetic acid drinking water disinfection byproducts

    PubMed Central

    Pals, Justin; Attene-Ramos, Matias S.; Xia, Menghang; Wagner, Elizabeth D.; Plewa, Michael J.

    2014-01-01

    Chronic exposure to drinking water disinfection byproducts has been linked to adverse health risks. The monohaloacetic acids (monoHAAs) are generated as byproducts during the disinfection of drinking water and are cytotoxic, genotoxic, mutagenic, and teratogenic. Iodoacetic acid toxicity was mitigated by antioxidants, suggesting the involvement of oxidative stress. Other monoHAAs may share a similar mode of action. Each monoHAA generated a significant concentration-response increase in the expression of a β-lactamase reporter under the control of the Antioxidant Response Element (ARE). The monoHAAs generated oxidative stress with a rank order of IAA > BAA >> CAA; this rank order was observed with other toxicological endpoints. Toxicogenomic analysis was conducted with a non-transformed human intestinal epithelial cell line (FHs 74 Int). Exposure to the monoHAAs altered the transcription levels of multiple oxidative stress responsive genes, indicating that each exposure generated oxidative stress. The transcriptome profiles showed an increase in TXNRD1 and SRXN1, suggesting peroxiredoxin proteins had been oxidized during monoHAA exposures. Three sources of reactive oxygen species were identified, the hypohalous acid generating peroxidase enzymes LPO and MPO, NADPH-dependent oxidase NOX5, and PTGS2 (COX-2) mediated arachidonic acid metabolism. Each monoHAA exposure caused an increase in COX-2 mRNA levels. These data provide a functional association between monoHAA exposure and adverse health outcomes such as oxidative stress, inflammation, and cancer. PMID:24050308

  13. An Evaluation of the Eclox Chemiluminescence Test, Hach Pesticide/Nerve Agent Test Strips, and Agri-Screen Test Tickets

    DTIC Science & Technology

    2010-06-30

    Interference Testing Our testing shows that it is unlikely that the Eclox Chemiluminescence Test will respond to the common disinfectant chloramine ...common disinfectants (chlorine and chloramine ), cyanobacterial byproducts (geosmin and MIB) or water quality parameters (humic/fulvic acids or water...toxicity sensor testing Table 2-2: Interferences Test Chemicals Concentration (mg/L) Chlorine 10 Chloramines 10 Geosmin 0.0001 Methyl-isoborneol

  14. Occurrence of regulated and emerging iodinated DBPs in the Shanghai drinking water.

    PubMed

    Wei, Xiao; Chen, Xin; Wang, Xia; Zheng, Weiwei; Zhang, Dong; Tian, Dajun; Jiang, Songhui; Ong, Choon Nam; He, Gengsheng; Qu, Weidong

    2013-01-01

    Drinking water chlorination plays a pivotal role in preventing pathogen contamination against water-borne disease. However, chemical disinfection leads to the formation of halogenated disinfection by products (DBPs). Many DBPs are highly toxic and are of health concern. In this study, we conducted a comprehensive measurements of DBPs, including iodoacetic acid (IAA), iodoform (IF), nine haloacetic acids and four trihalomethanes in drinking waters from 13 water plants in Shanghai, China. The results suggested that IAA and IF were found in all the water treatment plants, with maximum levels of 1.66 µg/L and 1.25 µg/L for IAA and IF, respectively. Owing to deterioration of water quality, the Huangpu River has higher IAA and IF than the Yangtze River. Our results also demonstrated that low pH, high natural organic matter, ammonia nitrogen, and iodide in source waters increased IAA and IF formation. Compared to chlorine, chloramines resulted in higher concentration of iodinated DBP, but reduced the levels of trihalomethanes. This is the first study to reveal the widespread occurrence of IAA and IF in drinking water in China. The data provide a better understanding on the formation of iodinated disinfection byproducts and the findings should be useful for treatment process improvement and disinfection byproducts controls.

  15. Occurrence of Regulated and Emerging Iodinated DBPs in the Shanghai Drinking Water

    PubMed Central

    Wei, Xiao; Chen, Xin; Wang, Xia; Zheng, Weiwei; Zhang, Dong; Tian, Dajun; Jiang, Songhui; Ong, Choon Nam; He, Gengsheng; Qu, Weidong

    2013-01-01

    Drinking water chlorination plays a pivotal role in preventing pathogen contamination against water-borne disease. However, chemical disinfection leads to the formation of halogenated disinfection by products (DBPs). Many DBPs are highly toxic and are of health concern. In this study, we conducted a comprehensive measurements of DBPs, including iodoacetic acid (IAA), iodoform (IF), nine haloacetic acids and four trihalomethanes in drinking waters from 13 water plants in Shanghai, China. The results suggested that IAA and IF were found in all the water treatment plants, with maximum levels of 1.66 µg/L and 1.25 µg/L for IAA and IF, respectively. Owing to deterioration of water quality, the Huangpu River has higher IAA and IF than the Yangtze River. Our results also demonstrated that low pH, high natural organic matter, ammonia nitrogen, and iodide in source waters increased IAA and IF formation. Compared to chlorine, chloramines resulted in higher concentration of iodinated DBP, but reduced the levels of trihalomethanes. This is the first study to reveal the widespread occurrence of IAA and IF in drinking water in China. The data provide a better understanding on the formation of iodinated disinfection byproducts and the findings should be useful for treatment process improvement and disinfection byproducts controls. PMID:23555742

  16. Inactivation of foodborne pathogenic and spoilage micro-organisms using ultraviolet-A light in combination with ferulic acid.

    PubMed

    Shirai, A; Watanabe, T; Matsuki, H

    2017-02-01

    The low energy of UV-A (315-400 nm) is insufficient for disinfection. To improve UV-A disinfection technology, we evaluated the effect of ferulic acid (FA) addition on disinfection by UV-A light-emitting diode (LED) (350-385 nm) against various food spoilers and pathogens (seven bacteria and four fungi species). Photoantimicrobial assays were performed at FA concentrations below the MIC. The MIC of the isomerized FA, consisting of 93% cis-form and 7% trans-form, was very similar to that of the commercially available FA (trans-form). Irradiation with UV-A (1·0 J cm -2 ) in the presence of 100 mg l -1 FA resulted in enhanced reducing of all of the tested bacterial strains. A combination of UV-A (10 J cm -2 ) and 1000 mg l -1 FA resulted in enhanced reducing of Saccharomyces cerevisiae and one of the tested filamentous fungi. These results demonstrated that the combination of a short-term application of UV-A and FA at a low concentration yielded synergistic enhancement of antimicrobial activity, especially against bacteria. Microbial contamination is one of the most serious problems for foods, fruit and sugar thick juices. UV light is suitable for the nonthermal decontamination of food products by inactivating the contaminating micro-organisms. However, UV-A exposure is insufficient for disinfection. This study demonstrates that the combination of UV-A LED light (350-385 nm), which is not hazardous to human eyes and skin, and ferulic acid (FA), a known phytochemical and food additive, provides synergistic antimicrobial activity against foodborne pathogenic and spoilage micro-organisms. Therefore, FA addition to UV-A light treatment may be useful for improvement of UV-A disinfection technology to prevent food deterioration. © 2016 The Society for Applied Microbiology.

  17. [Effect of antagonistic bacteria and soil disinfectant on soil bacterium community in banana Fusarium wilt disease area].

    PubMed

    Zhou, Dengbo; Jing, Tao; Tan, Xin; Chen, Bo; Zhang, Xiyan; Gao, Zhufen

    2013-08-04

    The objective of the present study is to elucidate the effects of the application of cake fertilizer fermentation fluid with antagonistic bacteria and soil disinfectant chlorine dioxide on the occurrence of banana fusarium wilt disease and soil bacterium community. Under the field cultivation conditions, the Biolog and T-RFLP method was used to investigate the soil bacterium diversity and community features in different treatments at different periods. The results show that both cake fertilizer fermentation fluid with antagonistic bacteria and soil disinfectant could reduce disease index of banana fusarium wilt disease significantly, the highest control effect could reach 60.82% with the combined application of these two methods. The result of Biolog eco plate shows that the application of cake fertilizer fermentation fluid with antagonistic bacteria could improve soil microbial AWCD (average well color development) and population uniformity, the use of soil disinfectant significantly reduced the soil microbial population's abundance and the uniformity. Principal component analysis shows that the soil microbial population using carbon source had an increasing trend throughout the banana growing season, the main carbon sources in the early stage were amino acids, carboxylic acids, amphiphilic compounds and carbohydrates, and the increased main carbon sources in the later stage were carboxylic acids and amphiphilic compounds. Soil bacterial diversity analysis by T-RFLP shows that the treatments of cake fertilizer fermentation fluid with antagonistic bacteria had the highest bacterial TRFs (Terminal restriction fragment) fragments, which resulted from the increase of Flavobacterium, Pseudomona and Lactobacillus population in the soil. The application of cake fertilizer fermentation fluid with antagonistic bacteria combining soil disinfectant could increase antagonistic microorganisms species, enhance soil microbial diversity, improve soil microbial ecological structure on the basis of reducing pathogen in soil, finally achieve the goal of improving the control effects of banana fusarium wilt disease.

  18. In vitro bioacessibility and transport across Caco-2 monolayers of haloacetic acids in drinking water.

    PubMed

    Melo, A; Faria, M A; Pinto, E; Mansilha, C; Ferreira, I M P L V O

    2016-10-01

    Water disinfection plays a crucial role in water safety but it is also a matter of concern as the use of disinfectants promotes the formation of disinfection by-products (DBPs). Haloacetic acids (HAAs) are one of the major classes of DBPs since they are frequently found in treated water, are ubiquitous, pervasive and have high water solubility, so a great concern emerged about their formation, occurrence and toxicity. Exposure to HAAs is influenced by consumption patterns and diet of individuals thus their bioavailability is an important parameter to the overall toxicity. In the current study the bioacessibility of the most representative HAAs (chloroacetic acid - MCAA, bromoacetic acid - MBAA, dichloroacetic acid - DCAA, dibromoacetic acid - DBAA, and trichloroacetic acid - TCAA) after simulated in vitro digestion (SIVD) in tap water and transport across Caco-2 monolayers was evaluated. Compounds were monitored in 8 points throughout the digestion phases by an optimized LC-MS/MS methodology. MCAA and MBAA were not bioaccessible after SIVD whereas DCAA, DBAA and TCAA are highly bioaccessible (85 ± 4%, 97 ± 4% and 106 ± 7% respectively). Concerning transport assays, DCAA and DBAA were highly permeable throughout the Caco-2 monolayer (apparent permeability and calculated fraction absorbed of 13.62 × 10(-6) cm/s and 90% for DCAA; and 8.82 × 10(-6) cm/s and 84% for DBAA), whereas TCAA showed no relevant permeability. The present results may contribute to efficient risk analysis studies concerning HAAs oral exposure from tap water taking into account the different biological behaviour of these chemically similar substances. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Effects of sterilization on optical and mechanical reliability of specialty optical fibers and terminations

    NASA Astrophysics Data System (ADS)

    Stolov, Andrei A.; Warych, Edward T.; Smith, William P.; Fournier, Paula L.; Hokansson, Adam S.; Li, Jie; Allen, R. Steve

    2014-02-01

    Optical fibers and terminations were subjected to different sterilization techniques, including multiple autoclaving and treatments with peracetic acid, E-beam and UV radiation. Effects of different sterilization techniques on key optical and mechanical properties of the fibers and the terminations were revealed. The primary attention was given to behavior of the coatings on the fibers and adhesives used in the terminations in harsh sterilization environments. The optical fibers with following four coating/buffer types were investigated: (i) dual acrylate, (ii) polyimide, (iii) silicone/PEEK and (iv) fluoroacrylate hard cladding/ETFE.

  20. Fundamental factors affecting biomass enzymatic reactivity.

    PubMed

    Chang, V S; Holtzapple, M T

    2000-01-01

    Poplar wood was treated with peracetic acid, KOH, and ball milling to produce 147 model lignocelluloses with a broad spectrum of lignin contents, acetyl contents, and crystallinity indices (CrIs), respectively. An empirical model was identified that describes the roles of these three properties in enzymatic hydrolysis. Lignin content and CrI have the greatest impact on biomass digestibility, whereas acetyl content has a minor impact. The digestibility of several lime-treated biomass samples agreed with the empirical model. Lime treatment removes all acetyl groups and a moderate amount of lignin and increases CrI slightly; lignin removal is the dominant benefit from lime treatment.

Top