Sample records for perchloroethylene dry cleaning

  1. EMISSIONS OF PERCHLOROETHYLENE FROM DRY CLEANED FABRICS

    EPA Science Inventory

    A study was conducted to evaluate the emissions of perchloroethylene (tetrachloroethylene) from dry cleaned fabrics to determine: (a) how the introduction of fresh dry cleaning into a home affects the indoor concentration of perchloroethylene, and (b) the effectiveness of ‘airing...

  2. Effects of retrofit emission controls and work practices on perchloroethylene exposures in small dry-cleaning shops.

    PubMed

    Ewers, Lynda M; Ruder, Avima M; Petersen, Martin R; Earnest, G Scott; Goldenhar, Linda M

    2002-02-01

    The effectiveness of commercially available interventions for reducing workers' perchloroethylene exposures in three small dry-cleaning shops was evaluated. Depending upon machine configuration, the intervention consisted of the addition of either a refrigerated condenser or a closed-loop carbon adsorber to the existing dry-cleaning machine. These relatively inexpensive (less than $5000) engineering controls were designed to reduce perchloroethylene emissions when dry-cleaning machine doors were opened for loading or unloading. Effectiveness of the interventions was judged by comparing pre- and postintervention perchloroethylene exposures using three types of measurements in each shop: (1) full-shift, personal breathing zone, air monitoring, (2) next-morning, end-exhaled worker breath concentrations of perchloroethylene, and (3) differences in the end-exhaled breath perchloroethylene concentrations before and after opening the dry-cleaning machine door. In general, measurements supported the hypothesis that machine operators' exposures to perchloroethylene can be reduced. However, work practices, especially maintenance practices, influenced exposures more than was originally anticipated. Only owners of dry-cleaning machines in good repair, with few leaks, should consider retrofitting them, and only after consultation with their machine's manufacturer. If machines are in poor condition, a new machine or alternative technology should be considered. Shop owners and employees should never circumvent safety features on dry-cleaning machines.

  3. Applicability Determination Letters for 40 C.F.R. Part 63 Subpart M, National Perchloroethylene Air Emission Standards for Dry Cleaning Facilities

    EPA Pesticide Factsheets

    This pages contains two letters on the applicability of the National Perchloroethylene Air Emission Standards for Dry Cleaning Facilities (40 CFR 63, Subpart M). Both letters clarify what constitutes instillation of a dry cleaning machine.

  4. An evaluation of retrofit engineering control interventions to reduce perchloroethylene exposures in commercial dry-cleaning shops.

    PubMed

    Earnest, G Scott; Ewers, Lynda M; Ruder, Avima M; Petersen, Martin R; Kovein, Ronald J

    2002-02-01

    Real-time monitoring was used to evaluate the ability of engineering control devices retrofitted on two existing dry-cleaning machines to reduce worker exposures to perchloroethylene. In one dry-cleaning shop, a refrigerated condenser was installed on a machine that had a water-cooled condenser to reduce the air temperature, improve vapor recovery, and lower exposures. In a second shop, a carbon adsorber was retrofitted on a machine to adsorb residual perchloroethylene not collected by the existing refrigerated condenser to improve vapor recovery and reduce exposures. Both controls were successful at reducing the perchloroethylene exposures of the dry-cleaning machine operator. Real-time monitoring was performed to evaluate how the engineering controls affected exposures during loading and unloading the dry-cleaning machine, a task generally considered to account for the highest exposures. The real-time monitoring showed that dramatic reductions occurred in exposures during loading and unloading of the dry-cleaning machine due to the engineering controls. Peak operator exposures during loading and unloading were reduced by 60 percent in the shop that had a refrigerated condenser installed on the dry-cleaning machine and 92 percent in the shop that had a carbon adsorber installed. Although loading and unloading exposures were dramatically reduced, drops in full-shift time-weighted average (TWA) exposures were less dramatic. TWA exposures to perchloroethylene, as measured by conventional air sampling, showed smaller reductions in operator exposures of 28 percent or less. Differences between exposure results from real-time and conventional air sampling very likely resulted from other uncontrolled sources of exposure, differences in shop general ventilation before and after the control was installed, relatively small sample sizes, and experimental variability inherent in field research. Although there were some difficulties and complications with installation and maintenance of the engineering controls, this study showed that retrofitting engineering controls may be a feasible option for some dry-cleaning shop owners to reduce worker exposures to perchloroethylene. By installing retrofit controls, a dry-cleaning facility can reduce exposures, in some cases dramatically, and bring operators into compliance with the Occupational Safety and Health Administration (OSHA) peak exposure limit of 300 ppm. Retrofit engineering controls are also likely to enable many dry-cleaning workers to lower their overall personal TWA exposures to perchloroethylene.

  5. National Emission Standards for Hazardous Air Pollutants (NESHAP) for Source Categories: Perchloroethylene Dry Cleaning Facilities - 1993 Final Rule (58 FR 49354)

    EPA Pesticide Factsheets

    This document is a copy of the Federal Register publication of the September 22, 1993 Final Rule for the National Emission Standards for Hazardous Air Pollutants for Source Categories: Perchloroethylene Dry Cleaning Facilities.

  6. Optic neuritis with residual tunnel vision in perchloroethylene toxicity.

    PubMed

    Onofrj, M; Thomas, A; Paci, C; Rotilio, D

    1998-01-01

    In a 57-year-old female owner of a dry-cleaning shop, we describe the association of severe bilateral optic neuritis with unexpectedly high concentrations of perchloroethylene/metabolites in the blood and of chloroform in urine. Visual disturbances consisted of complete blindness for 9 days in the left eye, for 11 days in the right eye, with bright phosphenes and pain on eye rotation. Only central (2-3 degrees radius) vision recovered in the following months. Although environmental concentrations of perchloroethylene were within normal limits, we measured five-fold increases in vapors emitted when ironing freshly dry-cleaned fabrics, and suggest that inhalation of perchloroethylene vapors was the cause of this case of ocular nerve toxicity, recapitulating a previous report of major perchloroethylene toxicity.

  7. Dry Cleaning Sector (NAICS 8123)

    EPA Pesticide Factsheets

    The dry cleaning sector includes establishments engaged in providing laundry services and industrial launderers. Find environmental regulatory information for perchloroethylene (PERC) cleaners as well as hazardous waste regulations for dry cleaners.

  8. Dry Cleaning Facilities: National Perchloroethylene Air Emission Standards

    EPA Pesticide Factsheets

    Learn about the Maximum Achievable Control Technology (MACT) standards for dry cleaning facilities. Find the rule history information, federal register citations, legal authority, and additional resources.

  9. PHOTOCHEMICAL REACTIVITY OF PERCHLOROETHYLENE

    EPA Science Inventory

    Perchloroethylene (PCE), a solvent used in dry cleaning, has been suspected of contributing significantly to photochemical ozone/oxidant (O3/Ox) problems in urban atmospheres. Past evidence, however, was neither complete nor consistent. To interpret more conclusively the past evi...

  10. PHOTOCHEMICAL REACTIVITY OF PERCHLOROETHYLENE: A NEW APPRAISAL

    EPA Science Inventory

    Perchloroethylene (PCE), a solvent used in dry cleaning, has been suspected of contributing significantly to photochemical ozone/oxidant (O3/O(x)) problems in urban atmospheres. Past evidence, however, was neither complete nor consistent. To interpret more conclusively the past e...

  11. 40 CFR 63.322 - Standards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...-perchloroethylene gas-vapor stream contained within each dry cleaning machine through a refrigerated condenser or an... contained within each dry cleaning machine through a refrigerated condenser or an equivalent control device...' specifications and recommendations. (e) Each refrigerated condenser used for the purposes of complying with...

  12. 40 CFR 63.322 - Standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... equivalent control device. (2) Route the air-perchloroethylene gas-vapor stream contained within each dry... contained within each dry cleaning machine through a refrigerated condenser or an equivalent control device... cleaning machine drum through a carbon adsorber or equivalent control device immediately before or as the...

  13. 40 CFR 63.322 - Standards.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... equivalent control device. (2) Route the air-perchloroethylene gas-vapor stream contained within each dry... contained within each dry cleaning machine through a refrigerated condenser or an equivalent control device... cleaning machine drum through a carbon adsorber or equivalent control device immediately before or as the...

  14. Socioeconomic disparities in indoor air, breath, and blood perchloroethylene level among adult and child residents of buildings with or without a dry cleaner.

    PubMed

    Storm, Jan E; Mazor, Kimberly A; Shost, Stephen J; Serle, Janet; Aldous, Kenneth M; Blount, Benjamin C

    2013-04-01

    In many cities, dry cleaners using perchloroethylene are frequently located in multifamily residential buildings and often cause elevated indoor air levels of perchloroethylene throughout the building. To assess individual perchloroethylene exposures associated with co-located dry cleaners, we measured perchloroethylene in residential indoor air, and in blood and breath of adults and children residing in buildings with a dry cleaner as part of the New York City (NYC) Perc Project. We also measured perchloroethylene in indoor air, and in blood and breath of residents of buildings without a dry cleaner for comparison. Here, we evaluate whether an environmental disparity in perchloroethylene exposures is present. Study participants are stratified by residential building type (dry cleaner or reference) and socioeconomic characteristics (race/ethnicity and income); measures of perchloroethylene exposure are examined; and, the influence of stratified variables and other factors on perchloroethylene exposure is assessed using multivariate regression. All measures of perchloroethylene exposure for residents of buildings with a dry cleaner indicated a socioeconomic disparity. Mean indoor air perchloroethylene levels were about five times higher in minority (82.5 ug/m(3)) than in non-minority (16.5 ug/m(3)) households, and about six times higher in low-income (105.5 ug/m(3)) than in high income (17.8 ug/m(3)) households. Mean blood perchloroethylene levels in minority children (0.27 ng/mL) and adults (0.46 ng/mL) were about two and three times higher than in non-minority children (0.12 ng/mL) and adults (0.15 ng/mL), respectively. Mean blood perchloroethylene levels in low income children (0.34 ng/mL) and adults (0.62 ng/mL) were about three and four times higher than in high income children (0.11 ng/mL) and adults (0.14 ng/mL), respectively. A less marked socioeconomic disparity was observed in perchloroethylene breath levels with minority and low income residents having slightly higher levels than non-minority and high income residents. Multivariate regression affirmed that indoor air perchloroethylene level in dry cleaner buildings was the single most important factor determining perchloroethylene in blood and breath. Neither age, gender, nor socioeconomic status significantly influenced perchloroethylene levels in breath or blood. We previously reported that increased indoor air, breath, and blood perchloroethylene levels among NYC Perc Project child participants were associated with an increased risk for slightly altered vision. Thus, the disproportionately elevated perchloroethylene exposures of minority and low-income child residents of buildings with a dry cleaner shown here constitutes an environmental exposure disparity with potential public health consequences. Among residents of buildings without a dry cleaner, we observed some small increases in perchloroethylene breath and blood levels among non-minority or high income residents compared to minority or low income residents. These differences were not attributable to differences in indoor air levels of perchloroethylene which did not differ across socioeconomic categories, but appear to be associated with more frequent exposures dry cleaned garments. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. ACUTE BEHAVIORAL EFFECTS OF INHALED PERCHLOROETHYLENE IN RATS ARE DIRECTLY RELATED TO ITS CONCENTRATION IN THE BRAIN.

    EPA Science Inventory

    Perchloroethylene (PCE) is a volatile organic compound (VOC), frequently used in dry cleaning processes, that is currently being assessed by EPA for its risk to human health. Many VOCs are acutely neurotoxic and have been shown to affect attentional processes in humans and animal...

  16. OCONUS Compliance Assessment Protocols -- OEBGD (Air Force and Marine Corps Version)

    DTIC Science & Technology

    2010-06-01

    new and existing perchloroethylene (PCE) dry -cleaning machines must be controlled. • Electroplating and anodizing tanks must comply with one of...and other contaminants from the surfaces of the parts or to dry the parts. Cleaning machines that contain and use heated, nonboiling solvent to clean...cement kilns that combust MSW, internal combustion engines, gas turbines, or other combustion devices that combust landfill gases collected by

  17. Towards sustainable and safe apparel cleaning methods: A review.

    PubMed

    Troynikov, Olga; Watson, Christopher; Jadhav, Amit; Nawaz, Nazia; Kettlewell, Roy

    2016-11-01

    Perchloroethylene (PERC) is a compound commonly used as a solvent in dry cleaning, despite its severe health and environmental impacts. In recent times chemicals such as hydrocarbons, GreenEarth(®), acetal and liquid carbon dioxide have emerged as less damaging substitutes for PERC, and an even more sustainable water-based wet cleaning process has been developed. We employed a systematic review approach to provide a comprehensive overview of the existing research evidence in the area of sustainable and safe apparel cleaning methods and care. Our review describes traditional professional dry cleaning methods, as well as those that utilise solvents other than PERC, and their ecological attributes. In addition, the new professional wet cleaning process is discussed. Finally, we address the health hazards of the various solvents used in dry cleaning and state-of-the-art solvent residue trace analysis techniques. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. A control technology evaluation of state-of-the-art, perchloroethylene dry-cleaning machines.

    PubMed

    Earnest, G Scott

    2002-05-01

    NIOSH researchers evaluated the ability of fifth-generation dry-cleaning machines to control occupational exposure to perchloroethylene (PERC). Use of these machines is mandated in some countries; however, less than 1 percent of all U.S. shops have them. A study was conducted at a U.S. dry-cleaning shop where two fifth-generation machines were used. Both machines had a refrigerated condenser as a primary control and a carbon adsorber as a secondary control to recover PERC vapors during the dry cycle. These machines were designed to lower the PERC concentration in the cylinder at the end of the dry cycle to below 290 ppm. A single-beam infrared photometer continuously monitors the PERC concentration in the machine cylinder, and a door interlock prevents opening until the concentration is below 290 ppm. Personal breathing zone air samples were measured for the machine operator and presser. The operator had time-weighted average (TWA) PERC exposures that were less than 2 ppm. Highest exposures occurred during loading and unloading the machine and when performing routine machine maintenance. All presser samples were below the limit of detection. Real-time video exposure monitoring showed that the operator had peak exposures near 160 ppm during loading and unloading the machine (below the OSHA maximum of 300 ppm). This exposure (160 ppm) is an order of magnitude lower than exposures with more traditional machines that are widely used in the United States. The evaluated machines were very effective at reducing TWA PERC exposures as well as peak exposures that occur during machine loading and unloading. State-of-the-art dry-cleaning machines equipped with refrigerated condensers, carbon adsorbers, drum monitors, and door interlocks can provide substantially better protection than more traditional machines that are widely used in the United States.

  19. 75 FR 61662 - State of California; Request for Approval of Section 112(l) Authority for Hazardous Air...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-06

    ...). ACTION: Proposed rule. SUMMARY: EPA is proposing to approve California's Airborne Toxic Control Measure... Resources Board (CARB) for approval to implement and enforce California's Airborne Toxic Control Measure for... Dry Cleaning ATCM California's Airborne Toxic Control Measure for Emissions of Perchloroethylene from...

  20. Degradation of Environmental Contaminants with Water-Soluble Cobalt Catalysts: An Integrative Inorganic Chemistry Investigation

    ERIC Educational Resources Information Center

    Evans, Alexandra L.; Messersmith, Reid E.; Green, David B.; Fritsch, Joseph M.

    2011-01-01

    We present an integrative laboratory investigation incorporating skills from inorganic chemistry, analytical instrumentation, and physical chemistry applied to a laboratory-scale model of the environmental problem of chlorinated ethylenes in groundwater. Perchloroethylene (C[subscript 2]Cl[subscript 4], PCE) a common dry cleaning solvent,…

  1. 40 CFR 52.2479 - Contents of the federally approved, State submitted implementation plan.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Perchloroethylene dry cleaning systems [02/19/91] 173-490-204 Graphic arts systems [02/19/91] 173-490-205 Surface...] 450 Emission Standards—Forward [04/14/93] 451 Emission of Air Contaminant—Visual Standards [10/13/94] 452 Motor Vehicle Visual Standard [04/14/93, except section .5] 455 Emission of Particulate Matter [04...

  2. Preliminary study of propyl bromide exposure among New Jersey dry cleaners as a result of a pending ban on perchloroethylene.

    PubMed

    Blando, James D; Schill, Donald P; De La Cruz, Mary Pauline; Zhang, Lin; Zhang, Junfeng

    2010-09-01

    Many states are considering, and some states have actively pursued, banning the use of perchloroethylene (PERC) in dry cleaning establishments. Proposed legislation has led many dry cleaners to consider the use of products that contain greater than 90% n-propyl bromide (n-PB; also called 1-bromopropane or 1-BP). Very little information is known about toxicity and exposure to n-PB. Some n-PB-containing products are marketed as nonhazardous and "green" or "organic." This has resulted in some users perceiving the solvent as nontoxic and has resulted in at least one significant poisoning incident in New Jersey. In addition, many dry cleaning operators may not realize that the machine components and settings must be changed when converting from PERC to n-PB containing products. Not performing these modifications may result in overheating and significant leaks in the dry cleaning equipment. A preliminary investigation was conducted of the potential exposures to n-PB and isopropyl bromide (iso-PB; also called 2-bromopropane or 2-BP) among dry cleaners in New Jersey who have converted their machines from PERC to these new solvent products. Personal breathing zone and area samples were collected using the National Institute for Occupational Safety and Health Sampling and Analytical Method 1025, with a slight modification to gas chromatography conditions to facilitate better separation of n-PB from iso-PB. During the preliminary investigation, exposures to n-PB among some workers in two of three shops were measured that were greater than the American Conference of Governmental Industrial Hygienists (ACGIH) threshold limit value (TLV) for n-PB. The highest exposure measured among a dry cleaning machine operator was 54 parts per million (ppm) as an 8-hr time-weighted average, which is more than 5 times the ACGIH TLV of 10 ppm. The preliminary investigation also found that the work tasks most likely to result in the highest short-term exposures included the introduction of solvent to the machine, maintenance of the machine, unloading and handling of recently cleaned clothes, and interrupting the wash cycle of the machine. In addition, this assessment suggested that leaks may have contributed to exposure and may have resulted from normal machine wear over time, ineffective maintenance, and from the incompatibility of n-PB with gasket materials.

  3. Risk Assessment: Perchloroethylene Dry Cleaners Refined Human Health Risk Characterization

    EPA Pesticide Factsheets

    This November 2005 memo and appendices describe the methods by which EPA conducted its refined risk assessment of the Major Source and Area Source facilities within the perchloroethylene (perc) dry cleaners source category.

  4. 75 FR 34647 - Approval of the Clean Air Act, Section 112(l), Authority for Hazardous Air Pollutants: Air...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-18

    ... solvent containing methylene chloride, perchloroethylene, trichloroethylene, 1,1,1-trichloroethane, carbon... sources to keep a record of the amount of perchloroethylene, trichloroethylene, and methylene chloride...

  5. PERCHLOROETHYLENE (PERC) INHIBITS FUNCTION OF VOLTAGE-GATED CALCIUM CHANNELS IN PHEOCHROMOCYTOMA CELLS.

    EPA Science Inventory

    The industrial solvent perchloroethylene (PERC) is listed as a hazardous air pollutant in the 1990 Ammendments to Clean Air Act and is a known neurotoxicant. However, the mechanisms by which PERC alters nervous system function are poorly understood. In recent years, it has been d...

  6. NEUROTOXICITY OF TETRACHLOROETHYLENE (PERCHLOROETHYLENE): DISCUSSION PAPER

    EPA Science Inventory

    This paper is a background document for a meeting of neurotoxicity experts to discuss the central nervous system effects of exposure to perchloroethylene (perc). The document reviews the literature on neurological testing of people exposed to perc occupationally in dry cleanin...

  7. 40 CFR 63.321 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... volatilize and recover perchloroethylene from contaminated perchloroethylene. Temperature sensor means a thermometer or thermocouple used to measure temperature. Transfer machine system means a multiple-machine dry... December 9, 1991. PCE gas analyzer means a flame ionization detector, photoionization detector, or infrared...

  8. 40 CFR 63.321 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... volatilize and recover perchloroethylene from contaminated perchloroethylene. Temperature sensor means a thermometer or thermocouple used to measure temperature. Transfer machine system means a multiple-machine dry... December 9, 1991. PCE gas analyzer means a flame ionization detector, photoionization detector, or infrared...

  9. 40 CFR 63.321 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... volatilize and recover perchloroethylene from contaminated perchloroethylene. Temperature sensor means a thermometer or thermocouple used to measure temperature. Transfer machine system means a multiple-machine dry... December 9, 1991. PCE gas analyzer means a flame ionization detector, photoionization detector, or infrared...

  10. 40 CFR 63.321 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... volatilize and recover perchloroethylene from contaminated perchloroethylene. Temperature sensor means a thermometer or thermocouple used to measure temperature. Transfer machine system means a multiple-machine dry... December 9, 1991. PCE gas analyzer means a flame ionization detector, photoionization detector, or infrared...

  11. 40 CFR 63.321 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... volatilize and recover perchloroethylene from contaminated perchloroethylene. Temperature sensor means a thermometer or thermocouple used to measure temperature. Transfer machine system means a multiple-machine dry... December 9, 1991. PCE gas analyzer means a flame ionization detector, photoionization detector, or infrared...

  12. Industrial-hygiene report, perchloroethylene, Carman's Classic Cleaners, Richmond, California, July 28, 1978

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ludwig, H.R.

    1978-03-01

    The survey was part of an industrywide mortality and industrial hygiene study of dry cleaning workers exposure to perchlorethylene. To gather data for this larger study, an on site visit was made to the Carman's Classic Cleaners located in Richmond, California. Carman's Classic Cleaners has been using PCE since the present owner had the building constructed in 1954. About 621 kilograms of clothing were dry cleaned each week, with about 129 liters of PCE consumed monthly. The workforce of six includes two pressers, a full time employee who works at the counter and also sews, a part time maintenance man,more » the owner, and his wife. The owner did all the dry cleaning and spotting while his wife marked clothing and worked the counter. Air samples were collected using battery operated pumps and charcoal tubes. The time weighted average exposure to PCE during the 5 hours of operation was 25 parts per million (ppm) for the dry cleaner and 2ppm for the presser. Samples collected in the vicinity of the front counter, washer, and spotting table indicated PCE levels of 3, 29, and 21ppm, respectively. Five minute peak samples during clothing transfer indicated PCE levels of 22, 38, and 17ppm. These exposures were well within the current standards. However, as PCE is a suspected carcinogen, it is necessary that levels be lowered as much as possible. The author recommends measures to help bring this about.« less

  13. Cleaning of uranium vs machine coolant formulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cristy, S.S.; Byrd, V.R.; Simandl, R.F.

    1984-10-01

    This study compares methods for cleaning uranium chips and the residues left on chips from alternate machine coolants based on propylene glycol-water mixtures with either borax, ammonium tetraborate, or triethanolamine tetraborate added as a nuclear poison. Residues left on uranium surfaces machined with perchloroethylene-mineral oil coolant and on surfaces machined with the borax-containing alternate coolant were also compared. In comparing machined surfaces, greater chlorine contamination was found on the surface of the perchloroethylene-mineral oil machined surfaces, but slightly greater oxidation was found on the surfaces machined with the alternate borax-containing coolant. Overall, the differences were small and a change tomore » the alternate coolant does not appear to constitute a significant threat to the integrity of machined uranium parts.« less

  14. Cancer and other causes of death among a cohort of dry cleaners.

    PubMed Central

    Blair, A; Stewart, P A; Tolbert, P E; Grauman, D; Moran, F X; Vaught, J; Rayner, J

    1990-01-01

    Mortality among 5365 members of a dry cleaning union in St. Louis, Missouri, was less than expected for all causes combined (SMR = 0.9) but slightly raised for cancer (SMR = 1.2). Among the cancers, statistically significant excesses occurred for oesophagus (SMR = 2.1) and cervix (SMR = 1.7) and non-significant excesses for larynx (SMR = 1.6), lung (SMR = 1.3), bladder (SMR = 1.7), thyroid (SMR = 3.3), lymphosarcoma and reticulosarcoma (SMR = 1.7), and Hodgkin's disease (SMR = 2.1). Mortality from emphysema was also significantly raised (SMR = 2.0). Eleven of the 13 deaths from oesophageal cancer occurred among black men. The risk of this cancer showed a significant association with estimated cumulative exposure to dry cleaning solvents (rising to 2.8-fold in the highest category) but not with level or duration of exposure. Mortality from kidney cancer was not excessive as reported in other studies. Excesses for emphysema and cancers of the larynx, lung, oesophagus, bladder, and cervix may be related to socioeconomic status, tobacco, or alcohol use. Although the number of deaths was small, the greatest risk for cancers of the lymphatic and haematopoietic system (fourfold) occurred among workers likely to have held jobs where exposures were the heaviest. Small numbers and limited information on exposure to specific substances complicates interpretation of this association but is unlikely to be due to confounding by tobacco use. It was not possible to identify workers exposed to specific dry cleaning solvents but mortality among those entering the union after 1960, when use of perchloroethylene was predominant, was similar to those entering before 1960. PMID:2328223

  15. 40 CFR 63.323 - Test methods and monitoring.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... air-perchloroethylene gas-vapor stream on the outlet side of the refrigerated condenser on a dry-to-dry machine, dryer, or reclaimer with a temperature sensor to determine if it is equal to or less than 7.2 °C (45 °F) before the end of the cool-down or drying cycle while the gas-vapor stream is flowing...

  16. 40 CFR 63.323 - Test methods and monitoring.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... air-perchloroethylene gas-vapor stream on the outlet side of the refrigerated condenser on a dry-to-dry machine, dryer, or reclaimer with a temperature sensor to determine if it is equal to or less than 7.2 °C (45 °F) before the end of the cool-down or drying cycle while the gas-vapor stream is flowing...

  17. IRIS Toxicological Review of Tetrachloroethylene ...

    EPA Pesticide Factsheets

    EPA conducted a peer review of the scientific basis supporting the human health hazard and dose-response assessment of tetrachloroethylene that will appear on the Integrated Risk Information System (IRIS) database. Peer review is meant to ensure that science is used credibly and appropriately in derivation of the toxicological characterization and dose-response assessments. This draft health assessment addresses both non-cancer and cancer human health effects that may result from chronic exposure to tetrachloroethylene (also called Perchloroethylene or Perc) . This is an update of an existing assessment posted on IRIS in 1988. This draft Toxicological Review includes a chronic Reference Concentration (RfC) and carcinogenicity assessment, which are not currently available on IRIS, as well as an update of the 1988 IRIS Reference Dose (RfD). Tetrachloroethylene is a chemical solvent that is widely used for dry cleaning of fabrics, metal degreasing, and in making some consumer products and other chemicals.

  18. Hot Oil Removes Wax

    NASA Technical Reports Server (NTRS)

    Herzstock, James J.

    1991-01-01

    Mineral oil heated to temperature of 250 degrees F (121 degrees C) found effective in removing wax from workpieces after fabrication. Depending upon size and shape of part to be cleaned of wax, part immersed in tank of hot oil, and/or interior of part flushed with hot oil. Pump, fittings, and ancillary tooling built easily for this purpose. After cleaning, innocuous oil residue washed off part by alkaline aqueous degreasing process. Serves as relatively safe alternative to carcinogenic and environmentally hazardous solvent perchloroethylene.

  19. Environmentally compatible hand wipe cleaning solvents

    NASA Technical Reports Server (NTRS)

    Clayton, Catherine P.; Kovach, Michael P.

    1995-01-01

    Several solvents of environmental concern have previously been used for hand wipe cleaning of SRB surfaces, including 1,1,1-trichloroethane, perchloroethylene, toluene, xylene, and MEK. USBI determined the major types of surfaces involved, and qualification requirements of replacement cleaning agents. Nineteen environmentally compatible candidates were tested on 33 material substrates with 26 types of potential surface contaminants, involving over 7,000 individual evaluations. In addition to the cleaning performance evaluation, bonding, compatibility, and corrosion tests were conducted. Results showed that one cleaner was not optimum for all surfaces. In most instances, some of the candidates cleaned better than the 1,1,1-trichloroethane baseline control. Aqueous cleaners generally cleaned better, and were more compatible with nonmetallic materials, such as paints, plastics, and elastomers. Organic base cleaners were better on metal surfaces. Five cleaners have been qualified and are now being implemented in SRB hand wipe cleaning operations.

  20. The Catalytic Effect of Electronegative Additives on Removal of Perchloroethylene Vapor from Air by Pulsed Corona Discharge

    NASA Astrophysics Data System (ADS)

    Filatov, I. E.; Uvarin, V. V.; Kuznetsov, D. L.

    2017-12-01

    It is established that electronegative additives (CCl4, freon-113) produce a catalytic effect on the conversion of volatile organic compounds (VOCs) under the action of atmospheric-pressure nonequilibrium plasma generated in pulsed corona discharge. At concentrations below 0.1%, these additives significantly decrease the discharge current, but the energy efficiency of the process of VOC removal from air increases. The catalytic effect of electronegative additives on the VOC conversion in air and nitrogen is quantitatively demonstrated in the case of perchloroethylene C2Cl4 (PCE) vapor removal. The addition of 0.085% CCl4 to air reduces the energy consumption for PCE removal at initial concentration of 0.09% by half (from 12 to 6 eV per molecule) at a 63% degree of cleaning. Mechanisms explaining the active inf luence of electronegative additives on the discharge current and the process of impurity removal are suggested.

  1. Apartment residents' and day care workers' exposures to tetrachloroethylene and deficits in visual contrast sensitivity.

    PubMed Central

    Schreiber, Judith S; Hudnell, H Kenneth; Geller, Andrew M; House, Dennis E; Aldous, Kenneth M; Force, Michael S; Langguth, Karyn; Prohonic, Elizabeth J; Parker, Jean C

    2002-01-01

    Tetrachloroethylene (also called perchloroethylene, or perc), a volatile organic compound, has been the predominant solvent used by the dry-cleaning industry for many years. The U.S. Environmental Protection Agency (EPA) classified perc as a hazardous air pollutant because of its potential adverse impact on human health. Several occupational studies have indicated that chronic, airborne perc exposure adversely affects neurobehavioral functions in workers, particularly visual color discrimination and tasks dependent on rapid visual-information processing. A 1995 study by Altmann and colleagues extended these findings, indicating that environmental perc exposure at a mean level of 4,980 microg/m(3) (median=1,360 microg/m(3)) alters neurobehavioral functions in residents living near dry-cleaning facilities. Although the U.S. EPA has not yet set a reference concentration guideline level for environmental exposure to airborne perc, the New York State Department of Health set an air quality guideline of 100 microg/m(3). In the current residential study, we investigated the potential for perc exposure and neurologic effects, using a battery of visual-system function tests, among healthy members of six families living in two apartment buildings in New York City that contained dry-cleaning facilities on the ground floors. In addition, a day care investigation assessed the potential for perc exposure and effects among workers at a day care center located in the same one-story building as a dry-cleaning facility. Results from the residential study showed a mean exposure level of 778 microg/m(3) perc in indoor air for a mean of 5.8 years, and that perc levels in breath, blood, and urine were 1-2 orders of magnitude in excess of background values. Group-mean visual contrast sensitivity (VCS), a measure of the ability to detect visual patterns, was significantly reduced in the 17 exposed study participants relative to unexposed matched-control participants. The groups did not differ in visual acuity, suggesting that the VCS deficit was of neurologic origin. Healthy workers in the day care investigation were chronically exposed to airborne perc at a mean of 2,150 microg/m(3) for a mean of 4.0 years. Again, group-mean VCS, measured 6 weeks after exposure cessation, was significantly reduced in the nine exposed workers relative to matched controls, and the groups did not differ significantly in visual acuity. These results suggested that chronic, environmental exposure to airborne perc adversely affects neurobehavioral function in healthy individuals. Further research is needed to assess the susceptibility of the young and elderly to perc-induced effects, to determine whether persistent solvent-induced VCS deficits are a risk factor for the development of neurologic disease, and to identify the no observable adverse effect level for chronic, environmental, perc exposure in humans. PMID:12117642

  2. Preparation of nuclear fuel spheres by flotation-internal gelation

    DOEpatents

    Haas, Paul A.; Fowler, Victor L.; Lloyd, Milton H.

    1987-01-01

    A simplified internal gelation process for the preparation of gel spheres of nuclear fuels. The process utilizes perchloroethylene as a gelation medium. Gelation is accomplished by directing droplets of a nuclear fuel broth into a moving volume of hot perchloroethylene (about 85.degree. C.) in a trough. Gelation takes place as the droplets float on the surface of the perchloroethylene and the resultant gel spheres are carried directly into an ager column which is attached to the trough. The aged spheres are disengaged from the perchloroethylene on a moving screen and are deposited in an aqueous wash column.

  3. FTIR quantification of industrial hydraulic fluids in perchloroethylene

    NASA Technical Reports Server (NTRS)

    Mehta, Narinder K.

    1993-01-01

    The purpose of this summer research project was to investigate whether perchloroethylene can be used as a solvent for the quantitative analysis of industrial hydraulic fluids by infrared spectroscopy employing Beer's law. Standard calibration curves using carbon-hydrogen stretching (generic) and ester absorption peaks were prepared for a series of standard dilutions at low ppm levels of concentration of seven hydraulic fluids in perchloroethylene. The absorbance spectras were recorded with 1.5-10 mm fixed and variable path length sample cells made of potassium bromide. The results indicate that using ester infrared spectral peak, it is possible to detect about 20 ppm of the hydraulic fluid in perchloroethylene.

  4. Preparation of nuclear fuel spheres by flotation-internal gelation

    DOEpatents

    Haas, P.A.; Fowler, V.L.; Lloyd, M.H.

    1984-12-21

    A simplified internal gelation process is claimed for the preparation of gel spheres of nuclear fuels. The process utilizes perchloroethylene as a gelation medium. Gelation is accomplished by directing droplets of a nuclear fuel broth into a moving volume of hot perchloroethylene (about 85/sup 0/C) in a trough. Gelation takes place as the droplets float on the surface of the perchloroethylene and the resultant gel spheres are carried directly into an ager column which is attached to the trough. The aged spheres are disengaged from the perchloroethylene on a moving screen and are deposited in an aqueous wash column. 3 figs.

  5. From Results to Action - Implementing an Indoor Air Quality Pilot Project

    NASA Astrophysics Data System (ADS)

    Collier, A. M.; Ware, G. E.; Iwasaki, P. G.; Billingsley, L. R.; Main, D.; Hannigan, M.; Pfotenhauer, D.

    2016-12-01

    One of the key differences between community-based participatory research (CBPR) and more conventional scientific research is the expectation that a project does not end with finalized results, but rather with taking action based on those results. Using an indoor air quality pilot project as an example, we will discuss how the consideration of potential actions and applications for the project findings should be integrated into planning throughout the life of a project. We will also share general reflections on effective CBPR from the perspective of both science and community partners on the project. In 2015, Taking Neighborhood Health to Heart (TNH2H), a community-based organization in Northeast Denver, researchers from the University of Colorado, Boulder, and AGU's Thriving Earth Exchange partnered to conduct a pilot project investigating indoor air quality in a Denver community. This partnership formed in response to community concerns about potential environmental contamination from dry cleaning operations, specifically through spills of the compound perchloroethylene. The exploration of the presence of radon, another indoor air quality concern common across the state of Colorado, was also added to the project. Using an iterative process, the team designed a sampling plan, selected a target location, and recruited homes and residents to participate in the pilot project. Radon and perchloroethylene data were then collected in 15 homes. Following data collection, results were first shared with project participants, after which de-identified data were shared with the members of TNH2H. Together TNH2H and researchers then developed strategies for public dissemination of the project findings. While we did not find levels of percholorethylene above the `action level' in any of the participating homes; however, we did find more frequent occurrences of radon levels above the `action level' than we had anticipated. For example, 80% of the homes in our study had radon levels requiring remediation while the reported average percentage for the Denver County is only 40% of homes. These results are currently driving our partnership to pursue actions that will lower residents' exposure to radon and improve public health in the TNH2H communities.

  6. Pulsed Discharge in Aerosol for Waste Water Clean-up.

    NASA Astrophysics Data System (ADS)

    Bystritskii, V. M.; Gonzales, A.; Olson, T.; Puchkarev, V.; Rosocha, L.; Wessel, F.; Yankelevich, Y.

    1996-11-01

    Aerosol (drop diameter of 10-100 μm) is injected into a discharge reactor with a repetitively pulsed voltage of 40--60 kV, 50--150 ns, 10^2--10^3 Hz. The relatively large water dielectric constant and high degree of atomization result in efficient degradation of organic molecules. Results on the characterization of operational parameters of the device and on degradation performance for a variety of organic pollutants (paranitrophenol, di-Chlorophenol, per-chloro-ethylene) are discussed. Work was supported by the Los Alamos National Laboratories 96 LACOR Program. ^AUniversity of Southern California, Los Angeles, CA 94007 ^BLos Alamos National Laboratory, Los Alamos, NM 87545

  7. 77 FR 38725 - Approval and Promulgation of Air Quality Implementation Plans; Indiana; Volatile Organic...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-29

    ... of aerosol adhesives containing methylene chloride, perchloroethylene, or trichloroethylene. --A..., perchloroethylene, or trichloroethylene. This section is at least as stringent as the OTC model rule, and therefore...

  8. 78 FR 26258 - Approval and Promulgation of Air Quality Implementation Plans; Illinois; Consumer Products and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-06

    ... 1, 2012, if they contain methylene chloride, perchloroethylene, or trichloroethylene. This section..., perchloroethylene, or trichloroethylene, but only if the compounds are present as impurities in a combined amount...

  9. Perchloroethylene: Multigeneration Inhalation Study in the Rat. Zeneca Tinston (11-03-1994)

    EPA Pesticide Factsheets

    The purpose of this study was to investigate the effect of inhalation of atomospheres containing perchloroethylene and the propagation of two generations of the Alpk:APfSD (Wistar-derived) strain of rat.

  10. CO2 (dry ice) cleaning system

    NASA Technical Reports Server (NTRS)

    Barnett, Donald M.

    1995-01-01

    Tomco Equipment Company has participated in the dry ice (solid carbon dioxide, CO2) cleaning industry for over ten years as a pioneer in the manufacturer of high density, dry ice cleaning pellet production equipment. For over four years Tomco high density pelletizers have been available to the dry ice cleaning industry. Approximately one year ago Tomco introduced the DI-250, a new dry ice blast unit making Tomco a single source supplier for sublimable media, particle blast, cleaning systems. This new blast unit is an all pneumatic, single discharge hose device. It meters the insertion of 1/8 inch diameter (or smaller), high density, dry ice pellets into a high pressure, propellant gas stream. The dry ice and propellant streams are controlled and mixed from the blast cabinet. From there the mixture is transported to the nozzle where the pellets are accelerated to an appropriate blasting velocity. When directed to impact upon a target area, these dry ice pellets have sufficient energy to effectively remove most surface coatings through dry, abrasive contact. The meta-stable, dry ice pellets used for CO2 cleaning, while labeled 'high density,' are less dense than alternate, abrasive, particle blast media. In addition, after contacting the target surface, they return to their equilibrium condition: a superheated gas state. Most currently used grit blasting media are silicon dioxide based, which possess a sharp tetrahedral molecular structure. Silicon dioxide crystal structures will always produce smaller sharp-edged replicas of the original crystal upon fracture. Larger, softer dry ice pellets do not share the same sharp-edged crystalline structures as their non-sublimable counterparts when broken. In fact, upon contact with the target surface, dry ice pellets will plastically deform and break apart. As such, dry ice cleaning is less harmful to sensitive substrates, workers and the environment than chemical or abrasive cleaning systems. Dry ice cleaning system components include: a dry ice pellet supply, a non-reactive propellant gas source, a pellet and propellant metering device, and a media transport and acceleration hose and nozzle arrangement. Dry ice cleaning system operating parameters include: choice of propellant gas, its pressure and temperature, dry ice mass flow rate, dry ice pellet size and shape, and acceleration nozzle configuration. These parameters may be modified to fit different applications. The growth of the dry ice cleaning industry will depend upon timely data acquisition of the effects that independent changes in these parameters have on cleaning rates, with respect to different surface coating and substrate combinations. With this data, optimization of cleaning rates for particular applications will be possible. The analysis of the applicable range of modulation of these parameters, within system component mechanical constraints, has just begun.

  11. INHIBITORY EFFECTS OF PERCHLOROETHYLENE ON HUMAN NEURONAL NICOTINIC ACETYLCHOLINE RECEPTORS.

    EPA Science Inventory

    Perchloroethylene (PERC) is a volatile organic solvent with a variety of industrial uses. PERC exposure has been shown to cause adverse neurological effects including deficits in vision and memory in exposed individuals. Despite knowledge of these effects, the mechanisms by whi...

  12. IRIS TOXICOLOGICAL REVIEW OF TETRACHLOROETHYLENE (PERCHLOROETHYLENE) (INTERAGENCY SCIENCE DISCUSSION DRAFT)

    EPA Science Inventory

    EPA is releasing the draft report, Toxicological Review of Tetrachloroethylene (Perchloroethylene), that was distributed to Federal agencies and White House Offices for comment during the Science Discussion step of the IRIS Assessment...

  13. PHASE BEHAVIOR OF WATER/PERCHLOROETHYLENE/ANIONIC SURFACTANT SYSTEMS

    EPA Science Inventory

    Winsor Type I (o/w), Type II (w/o), and Type III (middle phase) microemulsions have been generated for water and perchloroethylene (PCE) in combination with anionic surfactants and the appropriate electrolyte concentration. The surfactant formulation was a combination of sodium d...

  14. Residual tetrachloroethylene in dry-cleaned clothes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kawauchi, T.; Nishiyama, K.

    1989-04-01

    A large amount of residual tetrachloroethylene (TCE), up to 13.6 mg/g, was found in dry-cleaned clothes. The amounts varied among dry-cleaning establishments as well as with the type of fiber. The causes of these variations are discussed. Air TCE concentrations in the closed environment of dry-cleaning outlets were elevated: the highest reading was 4.8 mg/m3. The expired air of outlet employees also showed an increased level of TCE (average, 36.9 micrograms/m3). Increased air contamination from TCE released from dry-cleaned clothes was also observed in the home of a consumer. To reduce environmental contamination from TCE released from any of thesemore » sources, the amount of residual TCE in dry-cleaned clothes should be minimized.« less

  15. CATALYTIC STEAM REFORMING OF CHLOROCARBONS: TRICHLOROETHANE, TRICHLOROETHYLENE AND PERCHLOROETHYLENE. (R826694C633)

    EPA Science Inventory

    The effective destruction of trichloroethane, trichloroethylene and perchloroethylene by steam reforming with a commercial nickel catalyst has been demonstrated. Conversion levels of up to 0.99999 were attained in both laboratory and semi-pilot experiments, with the products c...

  16. Long-term perchloroethylene exposure: a limited meta-analysis of neurobehavorial deficits in occupationally and residentially exposed groups

    EPA Science Inventory

    The literature concerning the neurobehavioral and neurophysiological effects of long-term exposure to perchloroethylene (PERC) in humans was meta-analyzed to provide a quantitative review and synthesis. The useable data base from this literature comprised studies reporting effec...

  17. 9 CFR 590.547 - Albumen flake process drying operations.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... operations. (a) The fermentation, drying, and curing rooms shall be kept in a dust-free clean condition and free of flies, insects, and rodents. (b) Drying units, racks, and trucks shall be kept in a clean and... clean condition. (d) Oils and waxes used in oiling drying pans or trays shall be of edible quality. (e...

  18. 9 CFR 590.547 - Albumen flake process drying operations.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... operations. (a) The fermentation, drying, and curing rooms shall be kept in a dust-free clean condition and free of flies, insects, and rodents. (b) Drying units, racks, and trucks shall be kept in a clean and... clean condition. (d) Oils and waxes used in oiling drying pans or trays shall be of edible quality. (e...

  19. 9 CFR 590.547 - Albumen flake process drying operations.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... operations. (a) The fermentation, drying, and curing rooms shall be kept in a dust-free clean condition and free of flies, insects, and rodents. (b) Drying units, racks, and trucks shall be kept in a clean and... clean condition. (d) Oils and waxes used in oiling drying pans or trays shall be of edible quality. (e...

  20. 9 CFR 590.547 - Albumen flake process drying operations.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... operations. (a) The fermentation, drying, and curing rooms shall be kept in a dust-free clean condition and free of flies, insects, and rodents. (b) Drying units, racks, and trucks shall be kept in a clean and... clean condition. (d) Oils and waxes used in oiling drying pans or trays shall be of edible quality. (e...

  1. Toxicity of Military Unique Compounds in Aquatic Organisms: An Annotated Bibliography (Studies Published Through 1996)

    DTIC Science & Technology

    1998-04-01

    containing zinc, cadmium , arsenic, lead, aluminum, carbon tetrachloride, perchloroethylene, hexachloroethane, hexachlorobenzene, and hydrochloric...Siphonaptera/Solvent Dyes/Toxicity/Trout/Water/Zinc/SmokeMunitions/Propellants/Water Pollution/ Cadmium /Lead(Metal)/Carbon Tetrachloride/Aquatic Biology...combustion products that are a complex mixture containing zinc, cadmium , arsenic, lead, aluminum, carbon tetrachloride, perchloroethylene

  2. REPORT ON THE GEOELECTRICAL DETECTION OF SURFACTANT ENHANCED AQUIFER REMEDIATION OF PCE: PROPERTY CHANGES IN AQUEOUS SOLUTIONS DUE TO SURFACTANT TREATMENT OF PERCHLOROETHYLENE: IMPLICATIONS TO GEOPHYSICAL MEASUREMENTS

    EPA Science Inventory

    Select physicochemical properties of nine surfactants which are conventionally used in the remediation of perchloroethylene (PCE, a.k.a. tetrachloroethene) were evaluated with varying concentrations of PCE and indicator dyes in aqueous solutions using a response surface quadrati...

  3. 9 CFR 590.542 - Spray process drying operations.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ..., including sifters, conveyors, and powder coolers shall be either wet washed or dry cleaned. A combination of wet washing and dry cleaning of the complete drying unit shall not be permitted unless that segment of...

  4. 9 CFR 590.542 - Spray process drying operations.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ..., including sifters, conveyors, and powder coolers shall be either wet washed or dry cleaned. A combination of wet washing and dry cleaning of the complete drying unit shall not be permitted unless that segment of...

  5. 9 CFR 590.542 - Spray process drying operations.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ..., including sifters, conveyors, and powder coolers shall be either wet washed or dry cleaned. A combination of wet washing and dry cleaning of the complete drying unit shall not be permitted unless that segment of...

  6. 9 CFR 590.542 - Spray process drying operations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ..., including sifters, conveyors, and powder coolers shall be either wet washed or dry cleaned. A combination of wet washing and dry cleaning of the complete drying unit shall not be permitted unless that segment of...

  7. 9 CFR 590.542 - Spray process drying operations.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ..., including sifters, conveyors, and powder coolers shall be either wet washed or dry cleaned. A combination of wet washing and dry cleaning of the complete drying unit shall not be permitted unless that segment of...

  8. Cleaning Process Development for Metallic Additively Manufactured Parts

    NASA Technical Reports Server (NTRS)

    Tramel, Terri L.; Welker, Roger; Lowery, Niki; Mitchell, Mark

    2014-01-01

    Additive Manufacturing of metallic components for aerospace applications offers many advantages over traditional manufacturing techniques. As a new technology, many aspects of its widespread utilization remain open to investigation. Among these are the cleaning processes that can be used for post finishing of parts and measurements to verify effectiveness of the cleaning processes. Many cleaning and drying processes and measurement methods that have been used for parts manufactured using conventional techniques are candidates that may be considered for cleaning and verification of additively manufactured parts. Among these are vapor degreasing, ultrasonic immersion and spray cleaning, followed by hot air drying, vacuum baking and solvent displacement drying. Differences in porosity, density, and surface finish of additively manufactured versus conventionally manufactured parts may introduce new considerations in the selection of cleaning and drying processes or the method used to verify their effectiveness. This presentation will review the relative strengths and weaknesses of different candidate cleaning and drying processes as they may apply to additively manufactured metal parts for aerospace applications. An ultrasonic cleaning technique for exploring the cleanability of parts will be presented along with an example using additively manufactured Inconel 718 test specimens to illustrate its use. The data analysis shows that this ultrasonic cleaning approach results in a well-behaved ultrasonic cleaning/extraction behavior. That is, it does not show signs of accelerated cavitation erosion of the base material, which was later confirmed by neutron imaging. In addition, the analysis indicated that complete cleaning would be achieved by ultrasonic immersion cleaning at approximately 5 minutes, which was verified by subsequent cleaning of additional parts.

  9. 21 CFR 113.40 - Equipment and procedures.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... ensure a supply of clean, dry air. (3) Pressure gages. Each retort should be equipped with a pressure... should have adequate filter systems to ensure a supply of clean, dry air. (3) Pressure gages. (i) Each... controllers should have adequate filter systems to ensure a supply of clean, dry air. (3) Pressure gages. Each...

  10. 21 CFR 113.40 - Equipment and procedures.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... have adequate filter systems to ensure a supply of clean, dry air. A steam controller activated by the... ensure a supply of clean, dry air. (5) Steam introduction. Steam shall be distributed in the bottom of... temperature controllers should have adequate filter systems to ensure a supply of clean, dry air. (5) Bleeders...

  11. 21 CFR 113.40 - Equipment and procedures.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... have adequate filter systems to ensure a supply of clean, dry air. A steam controller activated by the... ensure a supply of clean, dry air. (5) Steam introduction. Steam shall be distributed in the bottom of... temperature controllers should have adequate filter systems to ensure a supply of clean, dry air. (5) Bleeders...

  12. 21 CFR 113.40 - Equipment and procedures.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... have adequate filter systems to ensure a supply of clean, dry air. A steam controller activated by the... ensure a supply of clean, dry air. (5) Steam introduction. Steam shall be distributed in the bottom of... temperature controllers should have adequate filter systems to ensure a supply of clean, dry air. (5) Bleeders...

  13. Efficacy of humidity retention bags for the reduced adsorption and improved cleaning of tissue proteins including prion-associated amyloid to surgical stainless steel surfaces.

    PubMed

    Secker, T J; Pinchin, H E; Hervé, R C; Keevil, C W

    2015-01-01

    Increasing drying time adversely affects attachment of tissue proteins and prion-associated amyloid to surgical stainless steel, and reduces the efficacy of commercial cleaning chemistries. This study tested the efficacy of commercial humidity retention bags to reduce biofouling on surgical stainless steel and to improve subsequent cleaning. Surgical stainless steel surfaces were contaminated with ME7-infected brain homogenates and left to dry for 15 to 1,440 min either in air, in dry polythene bags or within humidity retention bags. Residual contamination pre/post cleaning was analysed using Thioflavin T/SYPRO Ruby dual staining and microscope analysis. An increase in biofouling was observed with increased drying time in air or in sealed dry bags. Humidity retention bags kept both protein and prion-associated amyloid minimal across the drying times both pre- and post-cleaning. Therefore, humidity bags demonstrate a cheap, easy to implement solution to improve surgical instrument reprocessing and to potentially reduce associated hospital acquired infections.

  14. Evaluation of HEPA vacuum cleaning and dry steam cleaning in reducing levels of polycyclic aromatic hydrocarbons and house dust mite allergens in carpets

    PubMed Central

    Yu, Chang Ho; Yiin, Lih-Ming; Fan, Zhi-Hua (Tina); Rhoads, George G.

    2014-01-01

    Dry steam cleaning, which has gained recent attention as an effective method to reduce house dust mite (HDM) allergen concentration and loading in carpets, was evaluated in this study for its efficacy in lowering levels of polycyclic aromatic hydrocarbons (PAHs) as well as HDM allergens. Fifty urban homes with wail-to-wall carpets, mostly low-income and with known lead contamination, were studied in 2003 and 2004. Two carpet-cleaning interventions were compared: Repeated HEPA (High Efficiency Particulate Air filtered) vacuuming alone and repeated HEPA vacuuming supplemented with dry steam cleaning. Vacuum samples were collected to measure carpet loading of dust and contaminants immediately before and after cleaning. Paired comparisons were conducted to evaluate the effectiveness of the cleaning protocols in reducing the levels of PAHs and HDM allergens in carpets. The results indicated that both cleaning methods substantially reduced the loading of PAHs and HDM allergens as well as dust in carpets (p < 0.0001). The reductions in loading of dust (64.4%), PAHs (69.1%), and HDM allergens (85.5%), by dry steam cleaning plus repetitive HEPA vacuuming were larger than the reductions by regular HEPA vacuuming alone: dust (55.5%), PAHs (58.6%), and HDM allergens (80.8%), although the difference was statistically significant only for dust and PAHs. We conclude that intensive HEPA vacuum cleaning substantially reduced the loading of PAHs and HDM allergens in carpets in these urban homes and that dry steam cleaning added modestly to cleaning effectiveness. PMID:19137159

  15. A first French assessment of population exposure to tetrachloroethylene from small dry-cleaning facilities.

    PubMed

    Chiappini, L; Delery, L; Leoz, E; Brouard, B; Fagault, Y

    2009-06-01

    Used as a solvent in the dry-cleaning industry, tetrachloroethylene (C(2)Cl(4)) can be a pollutant of residential indoor air, which can cause long-term harmful exposures because of its neurotoxicity and probable carcinogenicity. In France, dry-cleaning facilities are integrated in urban environments (shopping malls, residential buildings) and can contribute to C(2)Cl(4) exposure for customers and residents. This exploratory work presents the results from five studies carried out in one shopping mall and four residential buildings housing a dry-cleaning facility. These studies involved dry-cleaning machines fitted with a Carbon Adsorber and unfitted, with or without Air Exhaust System. Samples were collected in the cleaning facilities and in the apartments located above with passive samplers allowing measurement of time-integrated concentrations on a 7 days sampling period. It has obviously shown the degradation of indoor air quality in these environments and underlined the contributing role of the machine technology and ventilation system on the amount of released C(2)Cl(4) in the indoor air. To temper these results, it must be pointed out that some parameters (building insulation, amount of solvent used...) which would influence C(2)Cl(4) fugitive release have not been quantified and should be looked at in further studies. In France, dry-cleaning facilities are frequently integrated in urban environments (large shopping malls or residential buildings) and can significantly contribute to tetrachloroethylene (C(2)Cl(4)) population exposure. The amount of fugitive releases in these environments depends on several parameters such as the dry-cleaning machine technology (fitted or unfitted with a carbon adsorber) and the ventilation (air exhaust system). To reduce C(2)Cl(4) exposure in residential buildings and other indoor environments with on-site dry cleaners, carbon adsorber unequipped machine should be replaced by newer technology and dry cleaners should be equipped with mechanical air exhaust systems.

  16. Proceedings: Fourteenth annual EPRI conference on fuel science

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1990-05-01

    EPRI's Fourteenth Annual Contractors' Conference on Fuel Science was held on May 18--19, 1989 in Palo Alto, CA. The conference featured results of work on coal science, coal liquefaction, methanol production, and coal oil coprocessing and coal upgrading. The following topics were discussed: recent development in coal liquefaction at the Wilsonville Clean Coal Research Center; British coal's liquid solvent extraction (LSE) process; feedstock reactivity in coal/oil co-processing; utility applications for coal-oil coprocessed fuels; effect of coal rank and quality on two-stage liquefaction; organic sulfur compounds in coals; the perchloroethylene refining process of high-sulfur coals; extraction of sulfur coals; extraction ofmore » sulfur from coal; agglomeration of bituminous and subbituminous coals; solubilization of coals by cell-free extracts derived from polyporus versicolor; remediation technologies and services; preliminary results from proof-of-concept testing of heavy liquid cyclone cleaning technology; clean-up of soil contaminated with tarry/oily organics; midwest ore processing company's coal benefication technology: recent prep plant, scale and laboratory activities; combustion characterization of coal-oil agglomerate fuels; status report on the liquid phase methanol project; biomimetic catalysis; hydroxylation of C{sub 2} {minus} C{sub 3} and cycloc{sub 6} hydrocarbons with Fe cluster catalysts as models for methane monooxygenase enzyme; methanol production scenarios; and modeling studies of the BNL low temperature methanol catalyst. Individual projects are processed separately for the data bases.« less

  17. Cancer in persons working in dry cleaning in the Nordic countries.

    PubMed

    Lynge, Elsebeth; Andersen, Aage; Rylander, Lars; Tinnerberg, Håkan; Lindbohm, Marja-Liisa; Pukkala, Eero; Romundstad, Pål; Jensen, Per; Clausen, Lene Bjørk; Johansen, Kristina

    2006-02-01

    U.S. studies have reported an increased risk of esophageal and some other cancers in dry cleaners exposed to tetrachloroethylene. We investigated whether the U.S. findings could be reproduced in the Nordic countries using a series of case-control studies nested in cohorts of laundry and dry-cleaning workers identified from the 1970 censuses in Denmark, Norway, Sweden, and Finland. Dry-cleaning work in the Nordic countries during the period when tetrachloroethylene was the dominant solvent was not associated with an increased risk of esophageal cancer [rate ratio (RR) = 0.76; 95% confidence interval (CI), 0.34-1.69], but our study was hampered by some unclassifiable cases. The risks of cancer of the gastric cardia, liver, pancreas, and kidney and non-Hodgkin lymphoma were not significantly increased. Assistants in dry-cleaning shops had a borderline significant excess risk of cervical cancer not found in women directly involved in dry cleaning. We found an excess risk of bladder cancer (RR = 1.44; 95% CI, 1.07-1.93) not associated with length of employment. The finding of no excess risk of esophageal cancer in Nordic dry cleaners differs from U.S. findings. Chance, differences in level of exposure to tetrachloroethylene, and confounding may explain the findings. The overall evidence on bladder cancer in dry cleaners is equivocal.

  18. The Influence of Contamination and Cleaning on the Strength of Modular Head Taper Fixation in Total Hip Arthroplasty.

    PubMed

    Krull, Annika; Morlock, Michael M; Bishop, Nicholas E

    2017-10-01

    Intraoperative interface contamination of modular head-stem taper junctions of hip implants can lead to poor fixation strength, causing fretting and crevice corrosion or even stem taper fracture. Careful cleaning before assembly should help to reduce these problems. The purpose of this study was to determine the effect of cleaning (with and without drying) contaminated taper interfaces on the taper fixation strength. Metal or ceramic heads were impacted onto titanium alloy stem tapers with cleaned or contaminated (fat or saline solution) interfaces. The same procedure was performed after cleaning and drying the contaminated interfaces. Pull-off force was used to determine the influence of contamination and cleaning on the taper strength. Pull-off forces after contamination with fat were significantly lower than those for uncontaminated interfaces for both head materials. Pull-off forces after application of saline solution were not significantly different from those for uncontaminated tapers. However, a large variation in taper strength was observed, pull-off forces for cleaned and dried tapers were similar to those for uncontaminated tapers for both head materials. Intraoperative contamination of taper interfaces may be difficult to detect but has a major influence on taper fixation strength. Cleaning of the stem taper with saline solution and drying with gauze directly before assembly allows the taper strength of the pristine components to be achieved. Not drying the taper results in a large variation in pull-off forces, emphasizing that drying is essential for sufficient and reproducible fixation strength. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Evaluation of two cleaning methods for the removal of asbestos fibers from carpet

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kominsky, J.R.; Freyberg, R.W.; Chesson, J.

    The research study examined the effectiveness of dry vacuuming and wet cleaning for the removal of asbestos fibers from carpet, and evaluated the potential for fiber reentrainment during carpet cleaning activities. Routine carpet cleaning operations using high-efficiency particulate air (HEPA) filtered dry vacuum cleaners and HEPA-filtered hot-water extraction cleaners were simulated on carpet artificially contaminated with asbestos fibers. Overall, wet cleaning the carpet with a hot-water extraction cleaner reduced the level of asbestos contamination by approximately 70 percent. There was no significant evidence of either an increase or a decrease in the asbestos concentration after dry vacuuming. The level ofmore » asbestos contamination had no significant effect on the difference between the carpet asbestos concentrations before and after cleaning. Airborne asbestos concentrations were between two and four times greater during the carpet cleaning activities. The level of asbestos contamination in the carpet cleaning activities. The level of asbestos contamination in the carpet and the type of cleaning method used had no statistically significant effect on the difference between the airborne asbestos concentrations before and during cleaning.« less

  20. Cancer in Persons Working in Dry Cleaning in the Nordic Countries

    PubMed Central

    Lynge, Elsebeth; Andersen, Aage; Rylander, Lars; Tinnerberg, Håkan; Lindbohm, Marja-Liisa; Pukkala, Eero; Romundstad, Pål; Jensen, Per; Clausen, Lene Bjørk; Johansen, Kristina

    2006-01-01

    U.S. studies have reported an increased risk of esophageal and some other cancers in dry cleaners exposed to tetrachloroethylene. We investigated whether the U.S. findings could be reproduced in the Nordic countries using a series of case–control studies nested in cohorts of laundry and dry-cleaning workers identified from the 1970 censuses in Denmark, Norway, Sweden, and Finland. Dry-cleaning work in the Nordic countries during the period when tetrachloroethylene was the dominant solvent was not associated with an increased risk of esophageal cancer [rate ratio (RR) = 0.76; 95% confidence interval (CI), 0.34–1.69], but our study was hampered by some unclassifiable cases. The risks of cancer of the gastric cardia, liver, pancreas, and kidney and non-Hodgkin lymphoma were not significantly increased. Assistants in dry-cleaning shops had a borderline significant excess risk of cervical cancer not found in women directly involved in dry cleaning. We found an excess risk of bladder cancer (RR = 1.44; 95% CI, 1.07–1.93) not associated with length of employment. The finding of no excess risk of esophageal cancer in Nordic dry cleaners differs from U.S. findings. Chance, differences in level of exposure to tetrachloroethylene, and confounding may explain the findings. The overall evidence on bladder cancer in dry cleaners is equivocal. PMID:16451857

  1. Use of history science methods in exposure assessment for occupational health studies

    PubMed Central

    Johansen, K; Tinnerberg, H; Lynge, E

    2005-01-01

    Aims: To show the power of history science methods for exposure assessment in occupational health studies, using the dry cleaning industry in Denmark around 1970 as the example. Methods: Exposure data and other information on exposure status were searched for in unconventional data sources such as the Danish National Archives, the Danish Royal Library, archives of Statistics Denmark, the National Institute of Occupational Health, Denmark, and the Danish Labor Inspection Agency. Individual census forms were retrieved from the Danish National Archives. Results: It was estimated that in total 3267 persons worked in the dry cleaning industry in Denmark in 1970. They typically worked in small shops with an average size of 3.5 persons. Of these, 2645 persons were considered exposed to solvents as they were dry cleaners or worked very close to the dry cleaning process, while 622 persons were office workers, drivers, etc in shops with 10 or more persons. It was estimated that tetrachloroethylene constituted 85% of the dry cleaning solvent used, and that a shop would normally have two machines using 4.6 tons of tetrachloroethylene annually. Conclusion: The history science methods, including retrieval of material from the Danish National Archives and a thorough search in the Royal Library for publications on dry cleaning, turned out to be a very fruitful approach for collection of exposure data on dry cleaning work in Denmark. The history science methods proved to be a useful supplement to the exposure assessment methods normally applied in epidemiological studies. PMID:15961618

  2. Use of history science methods in exposure assessment for occupational health studies.

    PubMed

    Johansen, K; Tinnerberg, H; Lynge, E

    2005-07-01

    To show the power of history science methods for exposure assessment in occupational health studies, using the dry cleaning industry in Denmark around 1970 as the example. Exposure data and other information on exposure status were searched for in unconventional data sources such as the Danish National Archives, the Danish Royal Library, archives of Statistics Denmark, the National Institute of Occupational Health, Denmark, and the Danish Labor Inspection Agency. Individual census forms were retrieved from the Danish National Archives. It was estimated that in total 3267 persons worked in the dry cleaning industry in Denmark in 1970. They typically worked in small shops with an average size of 3.5 persons. Of these, 2645 persons were considered exposed to solvents as they were dry cleaners or worked very close to the dry cleaning process, while 622 persons were office workers, drivers, etc in shops with 10 or more persons. It was estimated that tetrachloroethylene constituted 85% of the dry cleaning solvent used, and that a shop would normally have two machines using 4.6 tons of tetrachloroethylene annually. The history science methods, including retrieval of material from the Danish National Archives and a thorough search in the Royal Library for publications on dry cleaning, turned out to be a very fruitful approach for collection of exposure data on dry cleaning work in Denmark. The history science methods proved to be a useful supplement to the exposure assessment methods normally applied in epidemiological studies.

  3. 16 CFR 1610.2 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... mechanism of the test apparatus. (c) Dry cleaning means the cleaning of samples in a commercial dry cleaning... 1 second during which the ignition flame is applied to the test specimen. (g) Ignition means that there is a self-sustaining flame on the specimen after the test flame is removed. (h) Interlining means...

  4. 16 CFR 1610.2 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... mechanism of the test apparatus. (c) Dry cleaning means the cleaning of samples in a commercial dry cleaning... 1 second during which the ignition flame is applied to the test specimen. (g) Ignition means that there is a self-sustaining flame on the specimen after the test flame is removed. (h) Interlining means...

  5. 16 CFR § 1610.2 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... mechanism of the test apparatus. (c) Dry cleaning means the cleaning of samples in a commercial dry cleaning... 1 second during which the ignition flame is applied to the test specimen. (g) Ignition means that there is a self-sustaining flame on the specimen after the test flame is removed. (h) Interlining means...

  6. 16 CFR 1610.2 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... mechanism of the test apparatus. (c) Dry cleaning means the cleaning of samples in a commercial dry cleaning... 1 second during which the ignition flame is applied to the test specimen. (g) Ignition means that there is a self-sustaining flame on the specimen after the test flame is removed. (h) Interlining means...

  7. Effect of dry-cleaned clothes on tetrachloroethylene levels in indoor air, personal air, and breath for residents of several New Jersey homes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thomas, K.W.; Pellizzari, E.D.; Perritt, R.L.

    1991-10-01

    Several volatile organic compounds, including tetrachloroethylene, have been found to be nearly ubiquitous in residential indoor environments during previous TEAM studies. Eleven homes in New Jersey were monitored over three or five days to examine the effect of bringing freshly dry-cleaned clothes into the home on indoor air levels and personal exposures to tetrachloroethylene. Indoor air, personal air, and breath concentrations were measured over multiple 12-hrs periods before and after dry-cleaned clothes were introduced into nine of the homes. No dry-cleaned clothes were introduced into the two remaining homes. Outdoor air tetrachloroethylene concentrations were measured at six of the elevenmore » homes. Indoor/outdoor concentration ratios and source strengths were calculated at the six homes with outdoor measurements. Elevated indoor air levels and human exposures to tetrachloroethylene were measured at seven of the nine homes with dry-cleaned clothes. Indoor air concentrations reached 300 micrograms/m3 in one home and elevated indoor levels persisted for at least 48 hrs in all seven homes. Indoor/outdoor tetrachloroethylene concentration ratios exceeded 100 for the four homes with both dry-cleaned clothes and outdoor measurements. Maximum source strengths ranged from 16 to 69 mg/hr in these homes and did not directly correspond to the number of dry-cleaned garments brought into the home. Breath levels of tetrachloroethylene increased two to six-fold for participants living in seven homes with increased indoor air levels. Indoor air, personal air, and breath tetrachloroethylene concentrations were significantly related (0.05 level) to the number of garments introduced divided by the home volume.« less

  8. 48 CFR 237.7100 - Scope.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... DEFENSE SPECIAL CATEGORIES OF CONTRACTING SERVICE CONTRACTING Laundry and Dry Cleaning Services 237.7100 Scope. This subpart— (a) Applies to contracts for laundry and dry cleaning services within the United...

  9. 40 CFR 60.622 - Standards for volatile organic compounds.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... compounds. 60.622 Section 60.622 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Petroleum Dry Cleaners § 60.622 Standards for volatile organic compounds. (a) Each affected petroleum solvent dry cleaning dryer that is installed at a petroleum dry cleaning plant after December 14, 1982...

  10. 40 CFR 60.622 - Standards for volatile organic compounds.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... compounds. 60.622 Section 60.622 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Petroleum Dry Cleaners § 60.622 Standards for volatile organic compounds. (a) Each affected petroleum solvent dry cleaning dryer that is installed at a petroleum dry cleaning plant after December 14, 1982...

  11. 40 CFR 60.622 - Standards for volatile organic compounds.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... compounds. 60.622 Section 60.622 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Petroleum Dry Cleaners § 60.622 Standards for volatile organic compounds. (a) Each affected petroleum solvent dry cleaning dryer that is installed at a petroleum dry cleaning plant after December 14, 1982...

  12. In situ remediation of DNAPL compounds in low permeability media fate/transport, in situ control technologies, and risk reduction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-08-01

    In this project, in situ remediation technologies are being tested and evaluated for both source control and mass removal of dense, non-aqueous phase liquid (DNAPL) compounds in low permeability media (LPM). This effort is focused on chlorinated solvents (e.g., trichloroethylene and perchloroethylene) in the vadose and saturated zones of low permeability, massive deposits, and stratified deposits with inter-bedded clay lenses. The project includes technology evaluation and screening analyses and field-scale testing at both clean and contaminated sites in the US and Canada. Throughout this project, activities have been directed at understanding the processes that influence DNPAL compound migration and treatmentmore » in LPM and to assessing the operation and performance of the remediation technologies developed and tested. Selected papers are indexed separately for inclusion in the Energy Science and Technology Database.« less

  13. Cleaning process for EUV optical substrates

    DOEpatents

    Weber, Frank J.; Spiller, Eberhard A.

    1999-01-01

    A cleaning process for surfaces with very demanding cleanliness requirements, such as extreme-ultraviolet (EUV) optical substrates. Proper cleaning of optical substrates prior to applying reflective coatings thereon is very critical in the fabrication of the reflective optics used in EUV lithographic systems, for example. The cleaning process involves ultrasonic cleaning in acetone, methanol, and a pH neutral soap, such as FL-70, followed by rinsing in de-ionized water and drying with dry filtered nitrogen in conjunction with a spin-rinse.

  14. Rickett’s Dry Cleaning Site, Village of Ballston Spa, NY

    EPA Pesticide Factsheets

    The Rickett’s Dry Cleaning Site is located in a mixed commercial and residential area in the village of Ballston Spa on County Route 50. The site was the location of a family owned dry cleaner/ laundromat that went out of business in 2014. The site has

  15. PRECISION OF ATMOSPHERIC DRY DEPOSITION DATA FROM THE CLEAN AIR STATUS AND TRENDS NETWORK (CASTNET)

    EPA Science Inventory

    A collocated, dry deposition sampling program was begun in January 1987 by the US Environmental Protection Agency to provide ongoing estimates of the overall precision of dry deposition and supporting data entering the Clean Air Status and Trends Network (CASTNet) archives Duplic...

  16. Automated Array Assembly Task In-depth Study of Silicon Wafer Surface Texturizing

    NASA Technical Reports Server (NTRS)

    Jones, G. T.; Chitre, S.; Rhee, S. S.; Allison, K. L.

    1979-01-01

    A low cost wafer surface texturizing process was studied. An investigation of low cost cleaning operations to clean residual wax and organics from the surface of silicon wafers was made. The feasibility of replacing dry nitrogen with clean dry air for drying silicon wafers was examined. The two stage texturizing process was studied for the purpose of characterizing relevant parameters in large volume applications. The effect of gettering solar cells on photovoltaic energy conversion efficiency is described.

  17. Health-hazard-evaluation report MHETA 89-362-2027, Helen Mining Company, Homer City, Pennsylvania

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ferguson, R.P.

    1990-03-01

    In response to a request from the United Mine Workers of America, an investigation was made of possible hazardous working conditions at the Helen Mining Company, Homer City, Pennsylvania. One of the tipple operators had complained of headaches, dizziness and skin rashes from working with a mixture of solvents used in the float/sink test operation. The solvents included perchloroethylene and dibromomethane. A week prior to receiving the request, the use of dibromomethane had been discontinued. Consequently, on the visit to the site, no traces of dibromomethane were found. After engineering controls were installed, only one of seven personal breathing zonemore » samples detected any perchloroethylene, and that sample was 0.12 parts per million, at the limit of detection. The author concludes that a hazard from perchloroethylene did not exist at the time of the evaluation. The author recommends replacing the rubber/cloth type glove being used with either a Teflon or Viton glove, and enclosing the work table.« less

  18. SSME Main Combustion Chamber (MCC) hot oil dewaxing

    NASA Technical Reports Server (NTRS)

    Akpati, Anthony U.

    1995-01-01

    In an attempt to comply with the changing environmental regulations, a process was developed for the replacement of perchloroethylene in the dewaxing of the Space Shuttle Main Engine (SSME) Main Combustion Chamber (MCC) and other associated hardware filled with the Rigidax (R) casting compound. Rigidax (R) is a hard blue-dyed, calcium carbonate filled thermoplastic casting compound (melting point 77 C) that is melted and poured into hardware cavities to prevent contamination during material removal processes, i.e. machining, grinding, drilling, and deburring. Additionally, it serves as a maskant for designated areas during electroforming processes. Laboratory testing was conducted to evaluate seven alternate fluids for the replacement of perchloroethylene in the dewaxing process. Based upon successful laboratory results, a mineral oil was selected for testing on actual hardware. The final process developed involves simultaneous immersion and flushing of the MCC channels using a distinct eight stage process. A nonvolatile hydrocarbon analysis of a solvent flush sample is performed to determine the hardware cleanliness for comparison to the previous perchloroethylene dewaxing process.

  19. SSME Main Combustion Chamber (MCC) 'Hot Oil' Dewaxing

    NASA Technical Reports Server (NTRS)

    Akpati, Anthony U.

    1994-01-01

    In an attempt to comply with the changing environmental regulations, a process was developed for the replacement of perchloroethylene in the dewaxing of the Space Shuttle Main Engine (SSME) Main Combustion Chamber (MCC) and other associated hardware filled with the Rigidax(registered mark) casting compound. Rigidax(registered mark) is a hard blue-dyed, calcium carbonate filled thermoplastic casting compound (melting point 77 C) that is melted and poured into hardware cavities to prevent contamination during material removal processes, i.e. machining, grinding, drilling, and deburring. Additionally, it serves as a maskant for designated areas during electroforming processes. Laboratory testing was conducted to evaluate seven alternate fluids for the replacement of perchloroethylene in the dewaxing process. Based upon successful laboratory results, a mineral oil was selected for testing on actual hardware. The final process developed involves simultaneous immersion and flushing of the MCC channels using a distinct eight stage process. A nonvolatile hydrocarbon analysis of a solvent flush sample is performed to determine the hardware cleanliness for comparison to the previous perchloroethylene dewaxing process.

  20. 40 CFR 52.246 - Control of dry cleaning solvent vapor losses.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS California § 52.246 Control of dry... cleaning establishment that uses solvents containing 4 percent or more by volume of any reactive organic...

  1. Cleaning By Blasting With Pellets Of Dry Ice

    NASA Technical Reports Server (NTRS)

    Fody, Jody

    1993-01-01

    Dry process strips protective surface coats from parts to be cleaned, without manual scrubbing. Does not involve use of flammable or toxic solvents. Used to remove coats from variety of materials, including plastics, ceramics, ferrous and nonferrous metals, and composites. Adds no chemical-pollution problem to problem of disposal of residue of coating material. Process consists of blasting solid carbon dioxide (dry ice) pellets at surface to be cleaned. Pellets sublime on impact and pass into atmosphere as carbon dioxide gas. Size, harness, velocity, and quantity of pellets adjusted to suit coating material and substrate.

  2. Rapid formation of phase-clean 110 K (Bi-2223) powders derived via freeze-drying process

    DOEpatents

    Balachandran, Uthamalingam

    1996-01-01

    A process for the preparation of amorphous precursor powders for Pb-doped Bi.sub.2 Sr.sub.2 Ca.sub.2 Cu.sub.3 O.sub.x (2223) includes a freeze-drying process incorporating a splat-freezing step. The process generally includes splat freezing a nitrate solution of Bi, Pb, Sr, Ca, and Cu to form flakes of the solution without any phase separation; grinding the frozen flakes to form a powder; freeze-drying the frozen powder; heating the dried powder to form a dry green precursor powders; denitrating the green-powders; heating the denitrated powders to form phase-clean Bi-2223 powders. The grain boundaries of the 2223 grains appear to be clean, leading to good intergrain contact between 2223 grains.

  3. Rapid formation of phase-clean 110 K (Bi-2223) powders derived via freeze-drying process

    DOEpatents

    Balachandran, U.

    1996-06-04

    A process for the preparation of amorphous precursor powders for Pb-doped Bi{sub 2}Sr{sub 2} Ca{sub 2}Cu{sub 3}O{sub x} (2223) includes a freeze-drying process incorporating a splat-freezing step. The process generally includes splat freezing a nitrate solution of Bi, Pb, Sr, Ca, and Cu to form flakes of the solution without any phase separation; grinding the frozen flakes to form a powder; freeze-drying the frozen powder; heating the dried powder to form a dry green precursor powders; denitrating the green-powders; heating the denitrated powders to form phase-clean Bi-2223 powders. The grain boundaries of the 2223 grains appear to be clean, leading to good intergrain contact between 2223 grains. 11 figs.

  4. Dry cleaning of Turkish coal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cicek, T.

    2008-07-01

    This study dealt with the upgrading of two different type of Turkish coal by a dry cleaning method using a modified air table. The industrial size air table used in this study is a device for removing stones from agricultural products. This study investigates the technical and economical feasibility of the dry cleaning method which has never been applied before on coals in Turkey. The application of a dry cleaning method on Turkish coals designated for power generation without generating environmental pollution and ensuring a stable coal quality are the main objectives of this study. The size fractions of 5-8,more » 3-5, and 1-3 mm of the investigated coals were used in the upgrading experiments. Satisfactory results were achieved with coal from the Soma region, whereas the upgrading results of Hsamlar coal were objectionable for the coarser size fractions. However, acceptable results were obtained for the size fraction 1-3 mm of Hsamlar coal.« less

  5. Job Hazard Analyses for Musculoskeletal Disorder Risk Factors in Pressing Operations of Dry-cleaning Establishments.

    PubMed

    Park, Jung-Keun

    2016-12-01

    Job hazard analyses were conducted to assess exposure to musculoskeletal disorder (MSD) risk factors in seven workers of three dry-cleaning establishments. In accordance with the Washington State Ergonomics Rule, the analyses were performed in two separate steps: (1) observation and checklist approaches were made to identify a "caution zone job" in the seven workers' pressing operations across the three shops; and (2) detailed posture and motion analyses were undertaken to determine a "MSD hazard" in one worker's operation using a video technique. One "caution zone job" was identified and it was the pressing operation job in which five physical risk factors were found in the pressing operations. The detailed analyses confirmed that one "MSD hazard", i.e., awkward posture in shoulders, was prevalent in the pressing operations of the three dry-cleaning facilities. It would be desirable to reduce MSD risk factors including awkward shoulder posture in the dry-cleaning industry.

  6. Method for removal of beryllium contamination from an article

    DOEpatents

    Simandl, Ronald F.; Hollenbeck, Scott M.

    2012-12-25

    A method of removal of beryllium contamination from an article is disclosed. The method typically involves dissolving polyisobutylene in a solvent such as hexane to form a tackifier solution, soaking the substrate in the tackifier to produce a preform, and then drying the preform to produce the cleaning medium. The cleaning media are typically used dry, without any liquid cleaning agent to rub the surface of the article and remove the beryllium contamination below a non-detect level. In some embodiments no detectible residue is transferred from the cleaning wipe to the article as a result of the cleaning process.

  7. CLEANING OF FLUE GASES FROM WASTE COMBUSTORS

    EPA Science Inventory

    The paper addresses flue gas cleaning processes currently used commercially in waste combustion facilities. It also discusses the operating concepts of dry, semi-dry, and wet processes and their effectiveness in controlling various pollutants. Air pollutants from the combustion o...

  8. Higher prevalence of dry symptoms in skin, eyes, nose and throat among workers in clean rooms with moderate humidity.

    PubMed

    Su, Shih-Bin; Wang, Bour-Jr; Tai, Chien; Chang, Hsiu-Fen; Guo, How-Ran

    2009-01-01

    To determine whether working under relative humidity (RH) around 55 +/- 5% may lead to dry symptoms among workers in tropical regions. We recruited 3,154 Taiwanese workers who had no history of skin diseases and compared dry symptoms between clean room workers (RH around 55 +/- 5%) and other workers (RH around 65 +/- 5%). Clean room workers had higher prevalences of dry symptoms of the eye (odds ratio [OR]=1.62, 95% confidence interval [CI]: 1.40 to 1.86), nose and throat (OR=2.15, 95% CI: 1.66 to 2.79), and skin (OR=1.46, 95% CI: 1.23 to 1.73). In clean room workers, however, dry skin symptoms affected the palms (OR=1.72, 95% CI: 1.24 to 2.39), which are covered by gloves, more frequently than the face (OR=0.65, 95% CI: 0.45 to 0.94), which is exposed to the room air. We found working in clean rooms (adjusted OR [AOR]=1.38, 95% CI: 1.08 to 1.77), 24 to 30 yr of age (AOR=0.78, 95% CI: 0.62 to 0.99), family history of atopic diseases (AOR=1.75, 95% CI: 1.37 to 2.25), and skin moisturizer use (AOR=1.64, 95% CI: 1.30 to 2.06) were independent predictors of skin symptoms. In addition, working in clean rooms was an independent predictor of dry eye (AOR=1.30, 95% CI: 1.06 to 1.60) and dry nose and throat (AOR=1.70, 95% CI: 1.28 to 2.26) symptoms. Whereas the humidity in such working environments is not very low, for workers living in a high humidity environment, the relatively low humidity may still cause dry symptoms of the eye, nose, and throat.

  9. Identification of sewer pipes to be cleaned for reduction of CSO pollutant load.

    PubMed

    Nagaiwa, Akihiro; Settsu, Katsushi; Nakajima, Fumiyuki; Furumai, Hiroaki

    2007-01-01

    To reduce the CSO (Combined Sewer Overflow) pollutant discharge, one of the effective options is cleaning of sewer pipes before rainfall events. To maximize the efficiency, identification of pipes to be cleaned is necessary. In this study, we discussed the location of pipe deposit in dry weather in a combined sewer system using a distributed model and investigated the effect of pipe cleaning to reduce the pollutant load from the CSO. First we simulated the dry weather flow in a combined sewer system. The pipe deposit distribution in the network was estimated after 3 days of dry weather period. Several specific pipes with structural defect and upper end pipes tend to have an accumulation of deposit. Wet weather simulations were conducted with and without pipe cleaning in rainfall events with different patterns. The SS loads in CSO with and without the pipe cleaning were compared. The difference in the estimated loads was interpreted as the contribution of wash-off in the cleaned pipe. The effect of pipe cleaning on reduction of the CSO pollutant load was quantitatively evaluated (e.g. the cleaning of one specific pipe could reduce 22% of total CSO load). The CSO simulations containing pipe cleaning options revealed that identification of pipes with accumulated deposit using the distributed model is very useful and informative to evaluate the applicability of pipe cleaning option for CSO pollutant reduction.

  10. On the technological development of cotton primary processing, using a new drying-purifying unit

    NASA Astrophysics Data System (ADS)

    Agzamov, M. M.; Yunusov, S. Z.; Gafurov, J. K.

    2017-10-01

    The article reflects feasibility study of conducting research on technological development of cotton primary processing with the modified parameters of drying and cleaning process for small litter. As a result of theoretical and experimental research, drying and purifying unit is designed, in which in the existing processes a heat source, exhaust fans, a dryer drum, a peg-drum cleaner of cotton and the vehicle transmitting raw cotton from the dryer to the purifier will be excluded. The experience has shown that when a drying-purifying unit is installed (with eight wheels) purifying effect on the small litter of 34%, ie cleaning effect is higher than of that currently in operation 1XK drum cleaner. According to the research patent of RU UZ FAP 00674 “Apparatus for drying and cleaning fibrous material” is received.

  11. Causes of death among laundry and dry cleaning workers.

    PubMed Central

    Blair, A; Decoufle, P; Grauman, D

    1979-01-01

    To make a preliminary determination as to whether a potential health hazard exists for workers exposed to dry cleaning solvents (carbon tetrachloride, trichloroethylene, and tetrachloroethylene), we analyzed the causes of death of 330 deceased laundry and dry cleaning workers by the proportionate mortality method. The increased risk for malignant neoplasms resulted primarily from an excess of lung and cervical cancer and slight excesses of leukemia and liver cancer. Although the number of deaths was small, the increased risk of cancer noted in this investigation underscores the need for additional epidemiologic studies of this occupational group. PMID:434285

  12. Central venous catheter - dressing change

    MedlinePlus

    ... will need: Sterile gloves Cleaning solution A special sponge A special patch, called a Biopatch A clear ... around the catheter. Clean the skin with the sponge and cleaning solution. Air dry after cleaning. Place ...

  13. Combined wet and dry cleaning of SiGe(001)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, Sang Wook; Kaufman-Osborn, Tobin; Kim, Hyonwoong

    Combined wet and dry cleaning via hydrofluoric acid (HF) and atomic hydrogen on Si{sub 0.6}Ge{sub 0.4}(001) surface was studied at the atomic level using ultrahigh vacuum scanning tunneling microscopy (STM), scanning tunneling spectroscopy (STS), and x-ray photoelectron spectroscopy to understand the chemical transformations of the surface. Aqueous HF removes native oxide, but residual carbon and oxygen are still observed on Si{sub 0.6}Ge{sub 0.4}(001) due to hydrocarbon contamination from post HF exposure to ambient. The oxygen contamination can be eliminated by shielding the sample from ambient via covering the sample in the HF cleaning solution until the sample is introduced tomore » the vacuum chamber or by transferring the sample in an inert environment; however, both processes still leave carbon contaminant. Dry in-situ atomic hydrogen cleaning above 330 °C removes the carbon contamination on the surface consistent with a thermally activated atomic hydrogen reaction with surface hydrocarbon. A postdeposition anneal at 550 °C induces formation of an atomically flat and ordered SiGe surface observed by STM. STS verifies that the wet and dry cleaned surface has an unpinned Fermi level with no states between the conduction and valence band edge comparable to sputter cleaned SiGe surfaces.« less

  14. Development of megasonic cleaning for silicon wafers

    NASA Technical Reports Server (NTRS)

    Mayer, A.

    1980-01-01

    A cleaning and drying system for processing at least 2500 three in. diameter wafers per hour was developed with a reduction in process cost. The system consists of an ammonia hydrogen peroxide bath in which both surfaces of 3/32 in. spaced, ion implanted wafers are cleaned in quartz carriers moved on a belt past two pairs of megasonic transducers. The wafers are dried in the novel room temperature, high velocity air dryer in the same carriers used for annealing. A new laser scanner was used effectively to monitor the cleaning ability on a sampling basis.

  15. 21 CFR 526.820 - Erythromycin.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) Lactating cows: After milking, cleaning, and disinfecting, infuse contents of a single 6-milliliter syringe... infusions. (ii) Dry cows: After milking, cleaning, and disinfecting, infuse contents of a single 12... Streptococcus uberis in lactating or dry cows. (3) Limitations. Milk taken from animals during treatment and for...

  16. Moving zone Marangoni drying of wet objects using naturally evaporated solvent vapor

    DOEpatents

    Britten, Jerald A.

    1997-01-01

    A surface tension gradient driven flow (a Marangoni flow) is used to remove the thin film of water remaining on the surface of an object following rinsing. The process passively introduces by natural evaporation and diffusion of minute amounts of alcohol (or other suitable material) vapor in the immediate vicinity of a continuously refreshed meniscus of deionized water or another aqueous-based, nonsurfactant rinsing agent. Used in conjunction with cleaning, developing or wet etching application, rinsing coupled with Marangoni drying provides a single-step process for 1) cleaning, developing or etching, 2) rinsing, and 3) drying objects such as flat substrates or coatings on flat substrates without necessarily using heat, forced air flow, contact wiping, centrifugation or large amounts of flammable solvents. This process is useful in one-step cleaning and drying of large flat optical substrates, one-step developing/rinsing and drying or etching/rinsing/drying of large flat patterned substrates and flat panel displays during lithographic processing, and room-temperature rinsing/drying of other large parts, sheets or continuous rolls of material.

  17. Moving zone Marangoni drying of wet objects using naturally evaporated solvent vapor

    DOEpatents

    Britten, J.A.

    1997-08-26

    A surface tension gradient driven flow (a Marangoni flow) is used to remove the thin film of water remaining on the surface of an object following rinsing. The process passively introduces by natural evaporation and diffusion of minute amounts of alcohol (or other suitable material) vapor in the immediate vicinity of a continuously refreshed meniscus of deionized water or another aqueous-based, nonsurfactant rinsing agent. Used in conjunction with cleaning, developing or wet etching application, rinsing coupled with Marangoni drying provides a single-step process for (1) cleaning, developing or etching, (2) rinsing, and (3) drying objects such as flat substrates or coatings on flat substrates without necessarily using heat, forced air flow, contact wiping, centrifugation or large amounts of flammable solvents. This process is useful in one-step cleaning and drying of large flat optical substrates, one-step developing/rinsing and drying or etching/rinsing/drying of large flat patterned substrates and flat panel displays during lithographic processing, and room-temperature rinsing/drying of other large parts, sheets or continuous rolls of material. 5 figs.

  18. 9 CFR 318.305 - Equipment and procedures for heat processing systems.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... ensure a supply of clean, dry air. The recorder timing mechanism shall be accurate. (i) Chart-type... filter systems to ensure a supply of clean, dry air. (ii) Pressure recording device. Each retort shall be... section. (2) Cooling canal water shall be chlorinated or treated with a chemical approved by the...

  19. 9 CFR 381.305 - Equipment and procedures for heat processing systems.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... supply of clean, dry air. The recorder timing mechanism shall be accurate. (i) Chart-type devices... filter systems to ensure a supply of clean, dry air. (ii) Pressure recording device. Each retort shall be... cooling except as provided for in paragraphs (h) (2) and (3) of this section. (2) Cooling canal water...

  20. EVALUATION OF TWO CLEANING METHODS FOR THE REMOVAL OF ASBESTOS FIBERS FROM CARPET

    EPA Science Inventory

    This research study examined the effectiveness of dry vacuuming and wet cleaning for the removal of asbestos fibers from carpet, and evaluated the potential for fiber reentrainment during carpet cleaning activities. outine carpet cleaning operations using high-efficiency particul...

  1. Surgical wound care - closed

    MedlinePlus

    ... dressing. Wash your hands with soap and warm water. Also clean under your nails. Rinse, then dry your hands with a clean towel . Make sure you have all the supplies handy. Have a clean work surface. Remove the ...

  2. Laundry and Drycleaning Supervisor, 18-4. Military Curriculum Materials for Vocational and Technical Education.

    ERIC Educational Resources Information Center

    Ohio State Univ., Columbus. National Center for Research in Vocational Education.

    This instructional package for laundry/dry cleaning supervisor training has been adapted from military curriculum materials for use in vocational and technical education programs. The course is designed to train personnel to perform duties in the supervision and operation of a laundry/dry cleaning facility. This instructional package contains both…

  3. Residual contamination and corrosion on electrochemically marked uranium

    NASA Astrophysics Data System (ADS)

    Seals, R. D.; Bullock, J. S.; Cristy, S. S.; Bennett, R. K.

    Residual contamination and potential corrosion problems on uranium parts electrochemically marked with PHB-1 and PHB-1E electroetchants have been investigated using ion microprobe mass analysis (IMMA), scanning electron microscopy (SEM), and light microscopy (LM). The effectiveness of various solvent-cleaning sequences and the influence of the use of an abrasive cleaner were evaluated. The corrosion depths and chlorine distributions resulting from the electroetching process were determined. To meet the objective, the surfaces of uranium coupons, which had been processed according to production procedures for parts, i.e., machining, cleaning, marking, inspecting and coating with Shell Vitrea-29® oil, were studied. The greater surface wetting capability of the PHB-1E electroetchant solution relative to PHB-1 resulted in less localized corrosion at the point of attack which provided a more legible mark. Components of the electroetchants (aluminum, potassium and chromium) were found in the marked areas of both types of electroetched samples. Chromium, resulting from the corrosion inhibitor in the electroetchants, was found in the etched areas as well as on the coupon away from the electroetched areas. Depth profile data indicated that the major etching action (marking thickness) of the electroetchants penetrated to a depth of approximately 200 nm. Trace amounts of chlorine were present primarily within the first 65 nm of the marked surface. Comparison of the solvent rinsing sequences revealed that the most effective cleaning process included a degreaser, such as perchloroethylene, followed by a polar solvent, such as alcohol. Evaluation of the use of an abrasive cleaner on the electroetched areas indicates that this process removed residual contaminants, increased mark legibility and did not introduce significant residuals from the abrading material or cause significant surface damage.

  4. A new approach in dry technology for non-degrading optical and EUV mask cleaning

    NASA Astrophysics Data System (ADS)

    Varghese, Ivin; Smith, Ben; Balooch, Mehdi; Bowers, Chuck

    2012-11-01

    The Eco-Snow Systems group of RAVE N.P., Inc. has developed a new cleaning technique to target several of the advanced and next generation mask clean challenges. This new technique, especially when combined with Eco-Snow Systems cryogenic CO2 cleaning technology, provides several advantages over existing methods because it: 1) is solely based on dry technique without requiring additional complementary aggressive wet chemistries that degrade the mask, 2) operates at atmospheric pressure and therefore avoids expensive and complicated equipment associated with vacuum systems, 3) generates ultra-clean reactants eliminating possible byproduct adders, 4) can be applied locally for site specific cleaning without exposing the rest of the mask or can be used to clean the entire mask, 5) removes organic as well as inorganic particulates and film contaminations, and 6) complements current techniques utilized for cleaning of advanced masks such as reduced chemistry wet cleans. In this paper, we shall present examples demonstrating the capability of this new technique for removal of pellicle glue residues and for critical removal of carbon contamination on EUV masks.

  5. Removal of biofilm from contact lens storage cases.

    PubMed

    Wu, Yvonne T; Zhu, Hua; Willcox, Mark; Stapleton, Fiona

    2010-12-01

    Lens case hygiene practices are important in maintaining safe contact lens wear. However, the effectiveness of various lens case cleaning practices have not been evaluated and compared. This in vitro study aimed to evaluate and compare the efficacy of cleaning practices that are most commonly carried out by lens wearers and recommended by practitioners. Pseudomonas aeruginosa 122, Serratia marcescens ATCC 13880, and Staphylococcus aureus ATCC 6538 were the challenge bacteria for biofilm formation on unused lens cases from two different manufacturers. After establishment of the biofilm, each lens case was subjected to one of the six cleaning regimens: "rinsed," "rubbed and rinsed," "air-dried," "soaked in a multipurpose contact lens solution," "tissue-wiped," and "lids recapped." The level of residual biofilm was quantified at the end of each cleaning regimen. The efficacy of each cleaning regimen was then compared. Mechanical rubbing and wiping of lens cases were the most effective cleaning regimen tested in reducing biofilm. Soaking lenses in disinfecting solution for 6 hours removed the majority of biofilm from lens cases. Rinsing lens cases alone provided only minimal efficacy in reducing biofilm. Air-drying or recapping the cases with the lid without any other additional cleaning methods were the least efficient at removing biofilm. Based on this study, digital rubbing and rinsing and/or wiping the lens cases with tissue is recommended. Air-drying or recapping the lens case lids after use without any additional cleaning methods should be discouraged with non-antimicrobial lens cases.

  6. Female laundry and dry cleaning workers in Wisconsin: a mortality analysis.

    PubMed Central

    Katz, R M; Jowett, D

    1981-01-01

    The mortality patterns of 671 female laundry and dry cleaning workers for the period 1963--1977 were analyzed, using Wisconsin death certificate data. Results fail to show an overall increase in malignant neoplasms, but elevated risk was found for cancers of the kidney and genitals (unspecified), along with a smaller excess of bladder and skin cancer and lymphosarcoma. PMID:7468868

  7. Occupational solvent exposure and adult chronic lymphocytic leukemia: No risk in a population-based case-control study in four Nordic countries.

    PubMed

    Talibov, Madar; Auvinen, Anssi; Weiderpass, Elisabete; Hansen, Johnni; Martinsen, Jan-Ivar; Kjaerheim, Kristina; Tryggvadottir, Laufey; Pukkala, Eero

    2017-09-15

    The aim of this study was to assess the effect of occupational solvent exposure on the risk of adult chronic lymphocytic leukemia (CLL). The current case-control study was nested in the Nordic Occupational Cancer Study (NOCCA) cohort. 20,615 CLL cases diagnosed in 1961-2005 in Finland, Iceland, Norway, and Sweden, and 103,075 population-based controls matched by year of birth, sex, and country were included. Occupational histories for cases and controls were obtained from census records in 1960, 1970, 1980/1981, and 1990. Exposure to selected solvents was estimated by using the NOCCA job-exposure matrix (NOCCA-JEM). Odds ratios (OR) and 95% confidence intervals (95% CI) were estimated by using conditional logistic regression models. Overall, nonsignificant CLL risk elevations were observed for methylene chloride, perchloroethylene, and 1,1,1-trichloroethane. Compared to unexposed, significantly increased risks were observed for cumulative perchloroethylene exposure ≤13.3 ppm-years (OR = 1.85, 95% CI 1.16-2.96) and average life-time perchloroethylene exposure ≤2.5 ppm (1.61, 95% CI 1.01-2.56) among women, and cumulative methylene chloride exposure ≤12.5 ppm-years (OR = 1.19, 95% CI 1.01-1.41) and 12.5-74.8 ppm-years (OR = 1.23, 95% CI 1.01-1.51) among men in an analysis with 5 years lag-time, though without dose-response pattern. Decreased CLL risk was observed for aliphatic and alicyclic hydrocarbon solvents and toluene. This study did not support associations for solvent exposure and CLL. Observed weak associations for methylene chloride, perchloroethylene, 1,1,1-trichloroethane exposures, aliphatic and alicyclic hydrocarbons and toluene were not consistent across sexes, and showed no gradient with amount of exposure. © 2017 UICC.

  8. Inclusion of detergent in a cleaning regime and effect on microbial load in livestock housing.

    PubMed

    Hancox, L R; Le Bon, M; Dodd, C E R; Mellits, K H

    Determining effective cleaning and disinfection regimes of livestock housing is vital to improving the health of resident animals and reducing zoonotic disease. A cleaning regime consisting of scraping, soaking with or without detergent (treatment and control), pressure washing, disinfection and natural drying was applied to multiple pig pens. After each cleaning stage, samples were taken from different materials and enumerated for total aerobic count (TAC) and Enterobacteriaceae (ENT). Soaking with detergent (Blast-Off, Biolink) caused significantly greater reductions of TAC and ENT on metal, and TAC on concrete, compared with control. Disinfection effect (Virkon S, DuPont) was not significantly associated with prior detergent treatment. Disinfection significantly reduced TAC and ENT on concrete and stock board but not on metal. Twenty-four hours after disinfection TAC and ENT on metal and stock board were significantly reduced, but no significant reductions occurred in the subsequent 96 hours. Counts on concrete did not significantly reduce during the entire drying period (120 hours). Detergent and disinfectant have varying bactericidal effects according to the surface and bacterial target; however, both can significantly reduce microbial numbers so should be used during cleaning, with a minimum drying period of 24 hours, to lower bacterial counts effectively.

  9. Surface fixation of dried blood by glutaraldehyde and peracetic acid.

    PubMed

    Kampf, G; Bloss, R; Martiny, H

    2004-06-01

    The difficulties of successful prion inactivation by chemical agents has led to changes in recommendations regarding the reprocessing of instruments including flexible endoscopes. One of the changes is the preference for peracetic acid instead of glutaraldehyde in order to avoid fixation of organic material, but the surface fixation by various active agents has not been fully investigated. We used a standardized amount of dried blood soil on metal carriers (on average 22 mg). One part of the carriers was exposed to different disinfectants (four based on peracetic acid, three based on glutaraldehyde, two based on quaternary ammonium compounds (QAC), one based on QAC and amines, one based on phenols and one cleaning agent) and air dried. The difference compared with the non-exposed soiled carrier was taken as the measure of blood removal by exposure to the disinfectants. In addition the other part of the carriers was exposed to a cleaning agent and air dried. The cleaning agent itself was capable of removing more than 99% of the dried blood and served as a control for non-fixation. The rate of fixation of dried blood was calculated as the ratio of the weight of residual soil on 'soiled, disinfected and cleaned' carriers and on 'soiled and disinfected' carriers. All experiments were repeated eight times. Blood removal varied between 90.3% +/- 1.5% (phenol-based disinfectant) and < 10% (glutaraldehyde-based preparations). Fixation of the remainder was between 76.9 +/- 8.4% and 102.5 +/- 1.1% with glutaraldehyde and between 19.2% +/- 3.3% and 78.1% +/- 2.4% with peracetic acid. No other preparations showed a potential for blood fixation (< 1.3%). Our findings underline the potential for blood fixation, not only by glutaraldehyde, but also by peracetic acid, and support the evidence that effective cleaning should precede the chemical disinfection. Copyright 2004 The Hospital Infection Society

  10. 30 CFR 75.1101-22 - Inspection of dry powder chemical systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Inspection of dry powder chemical systems. 75...-22 Inspection of dry powder chemical systems. (a) Each dry powder chemical system shall be examined... the dry powder chemical system has been actuated, all components of the system shall be cleaned...

  11. 30 CFR 75.1101-22 - Inspection of dry powder chemical systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Inspection of dry powder chemical systems. 75...-22 Inspection of dry powder chemical systems. (a) Each dry powder chemical system shall be examined... the dry powder chemical system has been actuated, all components of the system shall be cleaned...

  12. 30 CFR 75.1101-22 - Inspection of dry powder chemical systems.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Inspection of dry powder chemical systems. 75...-22 Inspection of dry powder chemical systems. (a) Each dry powder chemical system shall be examined... the dry powder chemical system has been actuated, all components of the system shall be cleaned...

  13. 30 CFR 75.1101-22 - Inspection of dry powder chemical systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Inspection of dry powder chemical systems. 75...-22 Inspection of dry powder chemical systems. (a) Each dry powder chemical system shall be examined... the dry powder chemical system has been actuated, all components of the system shall be cleaned...

  14. Pramoxine

    MedlinePlus

    ... your hands. Clean the affected area with mild soap and warm water. Rinse thoroughly. Pat affected area ... your hands. Clean affected rectal area with mild soap and warm water. Rinse thoroughly. Gently dry by ...

  15. Tetrachloroethylene Exposure and Bladder Cancer Risk: A Meta-Analysis of Dry-Cleaning-Worker Studies

    PubMed Central

    Vlaanderen, Jelle; Straif, Kurt; Ruder, Avima; Blair, Aaron; Hansen, Johnni; Lynge, Elsebeth; Charbotel, Barbara; Loomis, Dana; Kauppinen, Timo; Kyyronen, Pentti; Pukkala, Eero; Weiderpass, Elisabete

    2014-01-01

    Background: In 2012, the International Agency for Research on Cancer classified tetrachloroethylene, used in the production of chemicals and the primary solvent used in dry cleaning, as “probably carcinogenic to humans” based on limited evidence of an increased risk of bladder cancer in dry cleaners. Objectives: We assessed the epidemiological evidence for the association between tetrachloroethylene exposure and bladder cancer from published studies estimating occupational exposure to tetrachloroethylene or in workers in the dry-cleaning industry. Methods: Random-effects meta-analyses were carried out separately for occupational exposure to tetrachloroethylene and employment as a dry cleaner. We qualitatively summarized exposure–response data because of the limited number of studies available. Results: The meta-relative risk (mRR) among tetrachloroethylene-exposed workers was 1.08 (95% CI: 0.82, 1.42; three studies; 463 exposed cases). For employment as a dry cleaner, the overall mRR was 1.47 (95% CI: 1.16, 1.85; seven studies; 139 exposed cases), and for smoking-adjusted studies, the mRR was 1.50 (95% CI: 0.80, 2.84; 4 case–control studies). Conclusions: Our meta-analysis demonstrates an increased risk of bladder cancer in dry cleaners, reported in both cohort and case–control studies, and some evidence for an exposure–response relationship. Although dry cleaners incur mixed exposures, tetrachloroethylene could be responsible for the excess risk of bladder cancer because it is the primary solvent used and it is the only chemical commonly used by dry cleaners that is currently identified as a potential bladder carcinogen. Relatively crude approaches in exposure assessment in the studies of “tetrachloroethylene-exposed workers” may have attenuated the relative risks. Citation: Vlaanderen J, Straif K, Ruder A, Blair A, Hansen J, Lynge E, Charbotel B, Loomis D, Kauppinen T, Kyyronen P, Pukkala E, Weiderpass E, Guha N. 2014. Tetrachloroethylene exposure and bladder cancer risk: a meta-analysis of dry-cleaning-worker studies. Environ Health Perspect 122:661–666; http://dx.doi.org/10.1289/ehp.1307055 PMID:24659585

  16. 9 CFR 590.547 - Albumen flake process drying operations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... free of flies, insects, and rodents. (b) Drying units, racks, and trucks shall be kept in a clean and sanitary condition. (c) Drying pans, trays, belts, scrapers, or curing racks, if used, shall be kept in a...

  17. MODELING VOLATILE ORGANIC COMPOUND PHARMACOKINETICS IN RAT PUPS

    EPA Science Inventory

    PBPK model predictions of internal dosimetry in young rats were compared to adult animals for benzene, chloroform (CHL), methylene chloride, methyl ethly ketone (MEK), perchloroethylene, and trichloroethylene.

  18. 40 CFR 63.461 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... the layer of air inside the solvent cleaning machine freeboard located above the solvent/air interface... speed from the initial loading of soiled or wet parts through the removal of the cleaned or dried parts... fresh unused solvent, recycled solvent, or used solvent that has been cleaned of soils (e.g., skimmed of...

  19. 40 CFR 63.461 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... the layer of air inside the solvent cleaning machine freeboard located above the solvent/air interface... speed from the initial loading of soiled or wet parts through the removal of the cleaned or dried parts... fresh unused solvent, recycled solvent, or used solvent that has been cleaned of soils (e.g., skimmed of...

  20. 40 CFR 63.461 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the layer of air inside the solvent cleaning machine freeboard located above the solvent/air interface... speed from the initial loading of soiled or wet parts through the removal of the cleaned or dried parts... fresh unused solvent, recycled solvent, or used solvent that has been cleaned of soils (e.g., skimmed of...

  1. 40 CFR 63.461 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... the layer of air inside the solvent cleaning machine freeboard located above the solvent/air interface... speed from the initial loading of soiled or wet parts through the removal of the cleaned or dried parts... fresh unused solvent, recycled solvent, or used solvent that has been cleaned of soils (e.g., skimmed of...

  2. ASRM process development in aqueous cleaning

    NASA Technical Reports Server (NTRS)

    Swisher, Bill

    1992-01-01

    Viewgraphs are included on process development in aqueous cleaning which is taking place at the Aerojet Advanced Solid Rocket Motor (ASRM) Division under a NASA Marshall Space and Flight Center contract for design, development, test, and evaluation of the ASRM including new production facilities. The ASRM will utilize aqueous cleaning in several manufacturing process steps to clean case segments, nozzle metal components, and igniter closures. ASRM manufacturing process development is underway, including agent selection, agent characterization, subscale process optimization, bonding verification, and scale-up validation. Process parameters are currently being tested for optimization utilizing a Taguci Matrix, including agent concentration, cleaning solution temperature, agitation and immersion time, rinse water amount and temperature, and use/non-use of drying air. Based on results of process development testing to date, several observations are offered: aqueous cleaning appears effective for steels and SermeTel-coated metals in ASRM processing; aqueous cleaning agents may stain and/or attack bare aluminum metals to various extents; aqueous cleaning appears unsuitable for thermal sprayed aluminum-coated steel; aqueous cleaning appears to adequately remove a wide range of contaminants from flat metal surfaces, but supplementary assistance may be needed to remove clumps of tenacious contaminants embedded in holes, etc.; and hot rinse water appears to be beneficial to aid in drying of bare steel and retarding oxidation rate.

  3. Inclusion of detergent in a cleaning regime and effect on microbial load in livestock housing

    PubMed Central

    Hancox, L. R.; Le Bon, M.; Dodd, C. E. R.; Mellits, K. H.

    2013-01-01

    Determining effective cleaning and disinfection regimes of livestock housing is vital to improving the health of resident animals and reducing zoonotic disease. A cleaning regime consisting of scraping, soaking with or without detergent (treatment and control), pressure washing, disinfection and natural drying was applied to multiple pig pens. After each cleaning stage, samples were taken from different materials and enumerated for total aerobic count (TAC) and Enterobacteriaceae (ENT). Soaking with detergent (Blast-Off, Biolink) caused significantly greater reductions of TAC and ENT on metal, and TAC on concrete, compared with control. Disinfection effect (Virkon S, DuPont) was not significantly associated with prior detergent treatment. Disinfection significantly reduced TAC and ENT on concrete and stock board but not on metal. Twenty-four hours after disinfection TAC and ENT on metal and stock board were significantly reduced, but no significant reductions occurred in the subsequent 96 hours. Counts on concrete did not significantly reduce during the entire drying period (120 hours). Detergent and disinfectant have varying bactericidal effects according to the surface and bacterial target; however, both can significantly reduce microbial numbers so should be used during cleaning, with a minimum drying period of 24 hours, to lower bacterial counts effectively. PMID:23839725

  4. 미국 환경 보호국 - 한국어

    EPA Pesticide Factsheets

    Environmental information translated into Korean covers topics including nail salons, dry-cleaning, drinking water, fish consumption, asthma, cleaning and disinfecting foot spa basins, pesticides, and professional fabricare processes.

  5. 9 CFR 354.243 - Operations and procedures.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...) The floors in the eviscerating room shall be kept clean and reasonably dry during eviscerating... handling equipment shall wear clean garments and should wear caps or hair nets, and shall keep their hands...

  6. Towards the development of a rapid, portable, surface enhanced Raman spectroscopy based cleaning verification system for the drug nelarabine.

    PubMed

    Corrigan, Damion K; Salton, Neale A; Preston, Chris; Piletsky, Sergey

    2010-09-01

    Cleaning verification is a scientific and economic problem for the pharmaceutical industry. A large amount of potential manufacturing time is lost to the process of cleaning verification. This involves the analysis of residues on spoiled manufacturing equipment, with high-performance liquid chromatography (HPLC) being the predominantly employed analytical technique. The aim of this study was to develop a portable cleaning verification system for nelarabine using surface enhanced Raman spectroscopy (SERS). SERS was conducted using a portable Raman spectrometer and a commercially available SERS substrate to develop a rapid and portable cleaning verification system for nelarabine. Samples of standard solutions and swab extracts were deposited onto the SERS active surfaces, allowed to dry and then subjected to spectroscopic analysis. Nelarabine was amenable to analysis by SERS and the necessary levels of sensitivity were achievable. It is possible to use this technology for a semi-quantitative limits test. Replicate precision, however, was poor due to the heterogeneous drying pattern of nelarabine on the SERS active surface. Understanding and improving the drying process in order to produce a consistent SERS signal for quantitative analysis is desirable. This work shows the potential application of SERS for cleaning verification analysis. SERS may not replace HPLC as the definitive analytical technique, but it could be used in conjunction with HPLC so that swabbing is only carried out once the portable SERS equipment has demonstrated that the manufacturing equipment is below the threshold contamination level.

  7. Evaluation of two methods for monitoring surface cleanliness-ATP bioluminescence and traditional hygiene swabbing.

    PubMed

    Davidson, C A; Griffith, C J; Peters, A C; Fielding, L M

    1999-01-01

    The minimum bacterial detection limits and operator reproducibility of the Biotrace Clean-Tracetrade mark Rapid Cleanliness Test and traditional hygiene swabbing were determined. Areas (100 cm2) of food grade stainless steel were separately inoculated with known levels of Staphylococcus aureus (NCTC 6571) and Escherichia coli (ATCC 25922). Surfaces were sampled either immediately after inoculation while still wet, or after 60 min when completely dry. For both organisms the minimum detection limit of the ATP Clean-Tracetrade mark Rapid Cleanliness Test was 10(4) cfu/100 cm2 (p < 0.05) and was the same for wet and dry surfaces. Both organism type and surface status (i.e. wet or dry) influenced the minimum detection limits of hygiene swabbing, which ranged from 10(2) cfu/100 cm2 to >10(7) cfu/100 cm2. Hygiene swabbing percentage recovery rates for both organisms were less than 0.1% for dried surfaces but ranged from 0.33% to 8.8% for wet surfaces. When assessed by six technically qualified operators, the Biotrace Clean-Tracetrade mark Rapid Cleanliness Test gave superior reproducibility for both clean and inoculated surfaces, giving mean coefficients of variation of 24% and 32%, respectively. Hygiene swabbing of inoculated surfaces gave a mean CV of 130%. The results are discussed in the context of hygiene monitoring within the food industry. Copyright 1999 John Wiley & Sons, Ltd.

  8. Asbestos-fiber reentrainment during dry vacuuming and wet cleaning of asbestos-contaminated carpet. Report for January 1988-July 1989

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kominsky, J.R.; Freyberg, R.W.

    A study was conducted to evaluate the potential for asbestos fiber reentrainment during cleaning of carpet contaminated with asbestos. Two types of carpet cleaning equipment were evaluated at two carpet contamination levels. Airborne asbestos concentrations were determined before and during carpet cleaning. Overall, airborne asbestos concentrations were two to four times greater during the carpet cleaning activity. The level of asbestos contamination and the type of cleaning method used had no statistically significant effect on the relative increase of airborne asbestos concentrations during carpet cleaning.

  9. Association between prenatal exposure to ambient diesel particulate matter and perchloroethylene with children's 3rd grade standardized test scores

    PubMed Central

    Stingone, Jeanette A.; McVeigh, Katharine H.; Claudio, Luz

    2016-01-01

    The objective of this research was to determine if prenatal exposure to two common urban air pollutants, diesel and perchloroethylene, affects children's 3rd grade standardized test scores in mathematics and English language arts (ELA). Exposure estimates consisted of annual average ambient concentrations of diesel particulate matter and perchloroethylene obtained from the Environmental Protection Agency's 1996 National Air Toxics Assessment for the residential census tract at birth. Outcome data consisted of linked birth and educational records for 201,559 singleton, non-anomalous children born between 1994-1998 who attended New York City public schools. Quantile regression models were used to estimate the effects of these exposures on multiple points within the continuous distribution of standardized test scores. Modified Poisson regression models were used to calculate risk ratios (RR) and 95% confidence intervals (CI) of failing to meet curricula standards, an indicator derived from test scores. Models were adjusted for a number of maternal, neighborhood and childhood factors. Results showed that math scores were approximately 6% of a standard deviation lower for children exposed to the highest levels of both pollutants as compared to children with low levels of both pollutants. Children exposed to high levels of both pollutants also had the largest risk of failing to meet math test standards when compared to children with low levels of exposure to the pollutants (RR 1.10 95%CI 1.07,1.12 RR high perchloroethylene only 1.03 95%CI 1.00,1.06; RR high diesel PM only 1.02 95%CI 0.99,1.06). There was no association observed between exposure to only one of the pollutants and failing to meet ELA standards. This study provides preliminary evidence of associations between prenatal exposure to urban air pollutants and lower academic outcomes. Additionally, these findings suggest that individual pollutants may additively impact health and point to the need to study the collective effects of air pollutant mixtures. Key Words: air toxics, academic outcomes, urban health, tetrachloroethylene, air pollutant mixtures PMID:27058443

  10. Investigating Indoor Air Quality Using a Community-based Participatory Research Model

    NASA Astrophysics Data System (ADS)

    Collier, A. M.; Ware, G. E.; Iwasaki, P. G.; Main, D.; Billingsley, L. R.; Pandya, R.; Hannigan, M.

    2015-12-01

    Our project seeks to expand scientific knowledge of air pollutant screening methods while also gathering data a community group can use to improve local health outcomes. Working with Taking Neighborhood Health to Heart (TNH2H), a Denver-based neighborhood group with significant experience doing community-based participatory research (CBPR) related to improving individual and community health, we designed a project to help residents test their homes for two contaminants of interest: radon and perchloroethylene. Radon is naturally occurring and commonly found across Colorado. Perchloroethylene contamination has been discovered in other parts of Denver and residents of Northeast Denver would like to learn more about its possible presence in their neighborhood. Additionally while radon is simple to test for, the same cannot be said for perchloroethylene. This project provides an opportunity to pilot a low-cost sampling method for perchloroethylene, apply TNH2H's CBPR model to an environmental health issue, adapt it for the geosciences, and engage the community in education around air quality issues. Data collected during the project will be shared with participating homes and the larger community. Community members will also participate in understanding and interpreting the data, and together community members and scientists will plan possible next steps, which may involve conducting further research, taking community action, or recommending changes in policy and practice. Beyond the local impacts, we are testing an air quality sampling method that could make sampling more accessible to a broader range of communities. We are also learning more about how communities and scientists can best work together and what additional resources can help facilitate and ensure successful implementation of these types of projects. Our partner, the Thriving Earth Exchange, will use what we learn to facilitate scientist-community partnerships like this in other communities around the world. We need to understand how to effectively engage in these partnerships because this model will allow us to collect and utilize much more data, particularly at the local level. This model of scientist-community collaboration is an important strategy for maximizing the public good that comes from geoscience research.

  11. Association between prenatal exposure to ambient diesel particulate matter and perchloroethylene with children's 3rd grade standardized test scores.

    PubMed

    Stingone, Jeanette A; McVeigh, Katharine H; Claudio, Luz

    2016-07-01

    The objective of this research was to determine if prenatal exposure to two common urban air pollutants, diesel and perchloroethylene, affects children's 3rd grade standardized test scores in mathematics and English language arts (ELA). Exposure estimates consisted of annual average ambient concentrations of diesel particulate matter and perchloroethylene obtained from the Environmental Protection Agency's 1996 National Air Toxics Assessment for the residential census tract at birth. Outcome data consisted of linked birth and educational records for 201,559 singleton, non-anomalous children born between 1994 and 1998 who attended New York City public schools. Quantile regression models were used to estimate the effects of these exposures on multiple points within the continuous distribution of standardized test scores. Modified Poisson regression models were used to calculate risk ratios (RR) and 95% confidence intervals (CI) of failing to meet curricula standards, an indicator derived from test scores. Models were adjusted for a number of maternal, neighborhood and childhood factors. Results showed that math scores were approximately 6% of a standard deviation lower for children exposed to the highest levels of both pollutants as compared to children with low levels of both pollutants. Children exposed to high levels of both pollutants also had the largest risk of failing to meet math test standards when compared to children with low levels of exposure to the pollutants (RR 1.10 95%CI 1.07,1.12 RR high perchloroethylene only 1.03 95%CI 1.00,1.06; RR high diesel PM only 1.02 95%CI 0.99,1.06). There was no association observed between exposure to the pollutants and failing to meet ELA standards. This study provides preliminary evidence of associations between prenatal exposure to urban air pollutants and lower academic outcomes. Additionally, these findings suggest that individual pollutants may additively impact health and point to the need to study the collective effects of air pollutant mixtures. air toxics, academic outcomes, urban health, tetrachloroethylene, air pollutant mixtures. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Markers

    ERIC Educational Resources Information Center

    Healthy Schools Network, Inc., 2011

    2011-01-01

    Dry erase whiteboards come with toxic dry erase markers and toxic cleaning products. Dry erase markers labeled "nontoxic" are not free of toxic chemicals and can cause health problems. Children are especially vulnerable to environmental health hazards; moreover, schools commonly have problems with indoor air pollution, as they are more densely…

  13. Adult Catheter Care and Infection Prevention Guide

    MedlinePlus

    ... or diluted bleach; and wipe with a clean paper towel. Work at a comfortable pace -- the risk ... soap (including under fingernails). • Dry with a clean paper towel. Turn water off with the back of ...

  14. 7 CFR 58.146 - Cleaning and sanitizing treatment.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... seal assemblies shall be removable on all agitators, pumps, and vats and shall be inspected at regular... above the floor in clean, dry locations and in a self draining position on racks constructed of...

  15. Experimental investigation on cleaning of corroded ancient coins using a Nd:YAG laser

    NASA Astrophysics Data System (ADS)

    Zhu, Huazhong; Lu, Jian; Ni, Xiaowu; Shen, Zhonghua

    2017-05-01

    The objective of the work reported is to study experimentally on the removal of corrosion layer from the ancient coins using laser beam as the conservation tool. With the use of Q-switched Nd:YAG laser radiation at 1064 nm, dry laser cleaning, steam laser cleaning and chemical-assisted laser cleaning were used to find out a more suitable and efficient laser treatment for corrosion removal. Cleaning tests were performed on ancient Chinese coins. Experimental results shows that the dry laser cleaning was not successful at removing all types of corrosion crust. It was possible to remove the outer thicker layer of the corrosion products (typically known as patina), but failed on the thinner layer of cuprite. The steam laser cleaning could decrease the initial removal threshold and improve the removal efficiency especially for the oxidation with powdery structure. As for chemical-assisted laser treatment, the cleaning results demonstrate that the combination of laser and chemical reagent could provide a considerable improvement in corrosion removal compared with the conventional laser treatments. Most of the corrosion contaminant was stripped, even the cuprite layer. Moreover, no secondary pollution was formed on the cleaned surface. X-ray fluorescence was applied to determine the variation of composition of surface layer and bulk metal before and after the coins cleaned. It shows that all of the three laser treatments were efficient to reduce the chlorine concentration on the surface of the coins more than 75%.

  16. Removal of residual contamination from clean protective clothing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hylko, J.M.; Miller, M.L.; Brehm, L.E.

    This paper reports that during 1986, a small but significant number of skin contamination incidents at Northern States Power Company's Monticello Nuclear Generating Plant were believed to have been caused by residual contamination in dry-cleaned protective clothing. A survey of 24 other nuclear power plants in May and June of 1986 indicated that about half of these facilities had experienced instances of sweat-induced skin contamination on persons wearing laundered, clean protective clothing, and a simple experiment showed that perspiration was indeed capable of removing residual contamination from the 100% cotton fabric used in the Monticello Plant's coveralls. In order tomore » further study this problem, a series of tests were performed on samples of the plant's protective clothing coveralls to determine how effective wet washing methods would be in removing residual contamination from this clothing, which previously had been laundered exclusively by dry cleaning.« less

  17. Sewers as a source and sink of chlorinated-solvent groundwater contamination, Marine Corps Recruit Depot, Parris Island, South Carolina

    USGS Publications Warehouse

    Vroblesky, D.A.; Petkewich, M.D.; Lowery, M.A.; Landmeyer, J.E.

    2011-01-01

    Groundwater contamination by tetrachloroethene and its dechlorination products is present in two partially intermingled plumes in the surficial aquifer near a former dry-cleaning facility at Site 45, Marine Corps Recruit Depot, Parris Island, South Carolina. The northern plume originates from the vicinity of former above-ground storage tanks. Free-phase tetrachloroethene from activities in this area entered the groundwater. The southern plume originates at a nearby, new dry-cleaning facility, but probably was the result of contamination released to the aquifer from a leaking sanitary sewer line from the former dry-cleaning facility. Discharge of dissolved groundwater contamination is primarily to leaking storm sewers below the water table. The strong influence of sanitary sewers on source distribution and of storm sewers on plume orientation and discharge at this site indicates that groundwater-contamination investigators should consider the potential influence of sewer systems at their sites. ?? 2011, National Ground Water Association.

  18. 7 CFR 58.220 - Drying systems.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... filter system shall comply with the applicable requirements of the 3-A Accepted Practices for Milk and Milk Products Spray Drying Systems. The filtering system shall be cleaned or component parts replaced... shall comply with the requirements of the 3-A Accepted Practices for Milk and Milk Products Spray Drying...

  19. 7 CFR 58.220 - Drying systems.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... filter system shall comply with the applicable requirements of the 3-A Accepted Practices for Milk and Milk Products Spray Drying Systems. The filtering system shall be cleaned or component parts replaced... shall comply with the requirements of the 3-A Accepted Practices for Milk and Milk Products Spray Drying...

  20. 7 CFR 58.220 - Drying systems.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... filter system shall comply with the applicable requirements of the 3-A Accepted Practices for Milk and Milk Products Spray Drying Systems. The filtering system shall be cleaned or component parts replaced... shall comply with the requirements of the 3-A Accepted Practices for Milk and Milk Products Spray Drying...

  1. 7 CFR 58.220 - Drying systems.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... filter system shall comply with the applicable requirements of the 3-A Accepted Practices for Milk and Milk Products Spray Drying Systems. The filtering system shall be cleaned or component parts replaced... shall comply with the requirements of the 3-A Accepted Practices for Milk and Milk Products Spray Drying...

  2. News Room | Argonne National Laboratory

    Science.gov Websites

    -friction dry lubricant that has hundreds of industrial applications and can be used virtually wherever two pieces of metal rub together in dry conditions. Left to right: Mathew Cherukara, Ali Erdemir, Badri dry lubricant Materials Today We need real scientific breakthroughs to build a clean energy economy

  3. 40 CFR 60.620 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Performance for Petroleum Dry Cleaners § 60.620 Applicability and designation of affected facility. (a) The provisions of this subpart are applicable to the following affected facilities located at a petroleum dry... pounds): Petroleum solvent dry cleaning dryers, washers, filters, stills, and settling tanks. (1) When...

  4. 7 CFR 58.229 - Filler and packaging equipment.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... construction and all parts, including valves and filler heads accessible for cleaning. New or replacement equipment should comply with the 3-A Sanitary Standards for equipment for Packaging Dry Milk and Dry Milk...

  5. Quantitative assessment of airborne exposures generated during common cleaning tasks: a pilot study

    PubMed Central

    2010-01-01

    Background A growing body of epidemiologic evidence suggests an association between exposure to cleaning products with asthma and other respiratory disorders. Thus far, these studies have conducted only limited quantitative exposure assessments. Exposures from cleaning products are difficult to measure because they are complex mixtures of chemicals with a range of physicochemical properties, thus requiring multiple measurement techniques. We conducted a pilot exposure assessment study to identify methods for assessing short term, task-based airborne exposures and to quantitatively evaluate airborne exposures associated with cleaning tasks simulated under controlled work environment conditions. Methods Sink, mirror, and toilet bowl cleaning tasks were simulated in a large ventilated bathroom and a small unventilated bathroom using a general purpose, a glass, and a bathroom cleaner. All tasks were performed for 10 minutes. Airborne total volatile organic compounds (TVOC) generated during the tasks were measured using a direct reading instrument (DRI) with a photo ionization detector. Volatile organic ingredients of the cleaning mixtures were assessed utilizing an integrated sampling and analytic method, EPA TO-17. Ammonia air concentrations were also measured with an electrochemical sensor embedded in the DRI. Results Average TVOC concentrations calculated for 10 minute tasks ranged 0.02 - 6.49 ppm and the highest peak concentrations observed ranged 0.14-11 ppm. TVOC time concentration profiles indicated that exposures above background level remained present for about 20 minutes after cessation of the tasks. Among several targeted VOC compounds from cleaning mixtures, only 2-BE was detectable with the EPA method. The ten minute average 2- BE concentrations ranged 0.30 -21 ppm between tasks. The DRI underestimated 2-BE exposures compared to the results from the integrated method. The highest concentration of ammonia of 2.8 ppm occurred during mirror cleaning. Conclusions Our results indicate that airborne exposures from short-term cleaning tasks can remain in the air even after tasks' cessation, suggesting potential exposures to anyone entering the room shortly after cleaning. Additionally, 2-BE concentrations from cleaning could approach occupational exposure limits and warrant further investigation. Measurement methods applied in this study can be useful for workplace assessment of airborne exposures during cleaning, if the limitations identified here are addressed. PMID:21118559

  6. Tetrachloroethylene

    Integrated Risk Information System (IRIS)

    EPA / 635 / R - 08 / 011F February 2012 TOXICOLOGICAL REVIEW OF Tetrachloroethylene ( Perchloroethylene ) ( CAS No . 127 - 18 - 4 ) In Support of Summary Information on the Integrated Risk Information System ( IRIS ) February 2012 U.S . Environmental Protection Agency Washington , DC ii DISCLAIMER T

  7. GTE_PEMTB_DC8 Parameters 15

    Atmospheric Science Data Center

    2013-02-19

    ... NMHC/Halocarbons/Alkyl Nitrates: Methyl Chloride F-12 F-114 F-11 HCFC-141B HCFC-134a HCFC-22 ... 2,2,4-trimethylpentane 2,3,4-trimethylpethane Methylene Chloride Chloroform Perchloroethylene HFC-134A HCFC22 ...

  8. Comparative stain removal properties of four commercially available denture cleaning products: an in vitro study.

    PubMed

    Alam, M; Jagger, R; Vowles, R; Moran, J

    2011-02-01

    Formulations of commercially available denture cleaners vary widely. Unfortunately, comparative data to suggest which products are the most effective can become invalid as newer products are introduced or formulations are changed. The aim of this in vitro study was to measure the stain removal properties of four currently available denture cleaners. Stain was deposited on multi-well polystyrene saliva coated microplates using multiple chlorhexidine and tea solutions. Following drying, each stained well was exposed to a solution of denture cleaner, dried again and the amount of stain remaining measured using a microplate reader. The cleaning procedure was repeated with further multiple exposures of the wells to solutions of the denture cleaners. All denture cleaners removed stain better than water used as a control. At five cleaning cycles only one of the cleaners (Superdrug Cleaning Powder) had removed 100% of the stain. At 30 cycles three of the cleaners had removed 100% of the stain. All the commercial denture cleaners removed stain. Superdrug Cleaning Powder, which contains sodium percarbonate and sodium lauryl sulphate, was particularly effective. © 2010 John Wiley & Sons A/S.

  9. GTE_PEMTB_P3B Parameters 17

    Atmospheric Science Data Center

    2013-02-19

    ... NMHC/Halocarbons/Alkyl Nitrates: Methyl Chloride F-12 F-114 F-11 HCFC-141B HCFC-134a HCFC-22 ... 2,2,4-trimethylpentane 2,3,4-trimethylpethane Methylene Chloride Chloroform Perchloroethylene HFC-134A HCFC22 ...

  10. 7 CFR 58.210 - Dry storage of product.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Specifications for Dairy Plants Approved for USDA Inspection and Grading Service 1 Rooms and Compartments § 58.210 Dry storage of product. Storage rooms for the dry storage of product shall be adequate in size, kept clean, orderly, free from rodents, insects, and mold, and maintained in good repair. They shall be...

  11. Non-steady state partitioning of dry cleaning surfactants between tetrachloroethylene (PCE) and water in porous media.

    PubMed

    Hoggan, James L; Bae, Keonbeom; Kibbey, Tohren C G

    2007-08-15

    Trapped organic solvents, in both the vadose zone and below the water table, are frequent sources of environmental contamination. A common source of organic solvent contamination is spills, leaks, and improper solvent disposal associated with dry cleaning processes. Dry cleaning solvents, such as tetrachloroethylene (PCE), are typically enhanced with the addition of surfactants to improve cleaning performance. The objective of this work was to examine the partitioning behavior of surfactants from PCE in contact with water. The relative rates of surfactants partitioning and PCE dissolution are important for modeling the behavior of waste PCE in the subsurface, in that they influence the interfacial tension of the PCE, and how (or if) interfacial tension changes over time in the subsurface. The work described here uses a flow-through system to examine simultaneous partitioning and PCE dissolution in a porous medium. Results indicate that both nonylphenol ethoxylate nonionic surfactants and a sulfosuccinate anionic surfactant partition out of residual PCE much more rapidly than the PCE dissolves, suggesting that in many cases interfacial tension changes caused by partitioning may influence infiltration and distribution of PCE in the subsurface. Non-steady-state partitioning is found to be well-described by a linear driving force model incorporating measured surfactant partition coefficients.

  12. The National Shipbuilding Research Program. Update Handbook for Surface Preparation and Coatings in Tanks and Confined Areas

    DTIC Science & Technology

    2000-10-31

    cleaning method are described in Naval Ships’ Technical Manual Chapter 631. 4.6.4 Citric Acid Cleaning The citric acid cleaning system is intended to...acquisition of necessary chemicals and tools, degreasing/cleaning, paint/stripping/removal, citric acid rust removal, passivation of bare steel, and drying...Figure 9-7 Hanging Explosion -Proof Light Box • Figure 9-8 Lighting in Tank • Figure 10-1 Hazardous Waste Storage Area • Figure 10-2 Solvent

  13. 21 CFR 880.6992 - Medical washer-disinfector.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... instruments, anesthesia equipment, hollowware, and other medical devices. (b) Classification. Class II...-disinfectors that are intended to clean, high level disinfect, and dry surgical instruments, anesthesia..., low or intermediate level disinfect, and dry surgical instruments, anesthesia equipment, hollowware...

  14. 21 CFR 880.6992 - Medical washer-disinfector.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... instruments, anesthesia equipment, hollowware, and other medical devices. (b) Classification. Class II...-disinfectors that are intended to clean, high level disinfect, and dry surgical instruments, anesthesia..., low or intermediate level disinfect, and dry surgical instruments, anesthesia equipment, hollowware...

  15. 21 CFR 880.6992 - Medical washer-disinfector.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... instruments, anesthesia equipment, hollowware, and other medical devices. (b) Classification. Class II...-disinfectors that are intended to clean, high level disinfect, and dry surgical instruments, anesthesia..., low or intermediate level disinfect, and dry surgical instruments, anesthesia equipment, hollowware...

  16. 21 CFR 880.6992 - Medical washer-disinfector.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... instruments, anesthesia equipment, hollowware, and other medical devices. (b) Classification. Class II...-disinfectors that are intended to clean, high level disinfect, and dry surgical instruments, anesthesia..., low or intermediate level disinfect, and dry surgical instruments, anesthesia equipment, hollowware...

  17. 21 CFR 880.6992 - Medical washer-disinfector.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... instruments, anesthesia equipment, hollowware, and other medical devices. (b) Classification. Class II...-disinfectors that are intended to clean, high level disinfect, and dry surgical instruments, anesthesia..., low or intermediate level disinfect, and dry surgical instruments, anesthesia equipment, hollowware...

  18. Characteristics and Functionalities of Natural and Bioinspired Nanomaterials

    DTIC Science & Technology

    2012-05-01

    toepads which are not recognized until small-scale examination. Another example is the identification of unique self -cleaning property of lotus...with self -cleaning capacity [4]. As in gecko toepads and lotus leaves, nature has evolved objects with high performance and multifunctionality using...which include self -repairing of wounds, self - cleaning of lotus leaves, energy conversation of chlorophyll, dry adhesion of gecko toepads, super

  19. Bench-scale performance testing and economic analyses of electrostatic dry coal cleaning. Final report, October 1980-July 1983

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rich, S.R.

    1987-02-01

    The report gives results of preliminary performance evaluations and economic analyses of the Advanced Energy Dynamics (AED) electrostatic dry coal-cleaning process. Grab samples of coal-feed-product coals were obtained from 25 operating physical coal-cleaning (PCC) plants. These samples were analyzed for ash, sulfur, and energy content and splits of the original samples of feed run-of-mine coal were provided for bench-scale testing in an electrostatic separation apparatus. The process showed superior sulfur-removal performance at equivalent cost and energy-recovery levels. The ash-removal capability of the process was not evaluated completely: overall, ash-removal results indicated that the process did not perform as well asmore » the PCC plants.« less

  20. Nondestructive Evaluation (NDE) Exploratory Development for Air Force Systems. Delivery Order 0001: Quick Reaction NDE and Characterization--Effects of Chemical Effects of Chemical Etching after Pre-Inspection Mechanical Cleaning on Fluorescent Penetrant Indications of Fatigue Cracks

    DTIC Science & Technology

    2011-08-01

    Specimen 625 -58 Cleaned with 50-ksi Water Jet ....................... 18 Figure 12. SEM Images of Inconel Specimen 626-63 Cleaned with 50-ksi Water...SEM Images of Inconel Specimen 626-22 Cleaned with Wet Glass Bead.......................... 21 Figure 15. SEM Images of Titanium Specimen 625 -02...Figure 18. SEM Images of Titanium Specimen 625 -40 Cleaned with Dry Al2O3 (240 grit) ............... 24 Figure 19. SEM Images of Inconel Specimen

  1. 17. VIEW OF THE DIAMOND MINEYARD LOOKING NORTHEAST. THE DRIES ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    17. VIEW OF THE DIAMOND MINEYARD LOOKING NORTHEAST. THE DRIES ARE ON THE LEFT, WITH THE TAR HOUSE, TOILET, AND ROPE CLAMP CLEANING BUILDING TO THE RIGHT - Butte Mineyards, Diamond Mine, Butte, Silver Bow County, MT

  2. Giving an IM (intramuscular) injection

    MedlinePlus

    ... Wash your hands well with soap and water. Dry them. Carefully find the spot where you will give the injection. Clean the skin at that spot with an alcohol wipe. Let it dry. Take the cap off the needle. Hold the ...

  3. DISPOSAL OF FLUE-GAS-CLEANING WASTES

    EPA Science Inventory

    The article describes current commercial and emerging technology for disposal of wastes from flue gas cleaning (FGC) systems for coal-fired power plants. Over 80 million metric tons/yr (dry) of coal ash and desulfurization solids are expected to be produced by the 1980's. Althoug...

  4. Floor cleaning: effect on bacteria and organic materials in hospital rooms.

    PubMed

    Andersen, B M; Rasch, M; Kvist, J; Tollefsen, T; Lukkassen, R; Sandvik, L; Welo, A

    2009-01-01

    Routine surface cleaning is recommended to control the spread of pathogens in hospital environments. In Norway, ordinary cleaning of patient rooms is traditionally performed with soap and water. In this study, four floor-mopping methods--dry, spray, moist and wet mopping--were compared by two systems using adenosine triphosphate (ATP) bioluminescence (Hygiena and Biotrace). These systems assess residual organic soil on surfaces. The floor-mopping methods were also assessed by microbiological samples from the floor and air, before and after cleaning. All methods reduced organic material on the floors but wet and moist mopping seemed to be the most effective (P < 0.001, P < 0.011, respectively, ATP Hygiena). The two ATP methods were easy to use, although each had their own reading scales. Cleaning reduced organic material to 5-36% of the level present before cleaning, depending upon mopping method. All four mopping methods reduced bacteria on the floor from about 60-100 to 30-60 colony-forming units (cfu)/20cm2 floor. Wet, moist and dry mopping seemed to be more effective in reducing bacteria on the floor, than the spray mopping (P=0.007, P=0.002 and P=0.011, respectively). The burden of bacteria in air increased for all methods just after mopping. The overall best cleaning methods seemed to be moist and wet mopping.

  5. MICROSCOPIC OBSERVATION AND QUANTIFICATION OF ENHANCED DNAPL REMOVAL BY COSOLVENT-AIR FLOODING

    EPA Science Inventory

    The simultaneous injection of cosolvent and air has been suggested to improve sweep efficiency of cosolvent flooding for dense nonaqueous phase liquid (DNAPL) remediation. Glass micromodel experiments were conducted to investigate the factors that influence perchloroethylene (PCE...

  6. TRICHLOROETHYLENE IHIBITS VOLTAGE-SENSITIVE CALCIUM CURRENTS IN DIFFERENTIATED PC 12 CELLS.

    EPA Science Inventory

    ABSTRACT BODY: It has been demonstrated recently that volatile organic compounds (VOCs)such as toluene, perchloroethylene and trichloroethylene inhibit function of voltage-sensitive calcium channels (VSSC). Such actions are hypothesized to contribute to the acute neurotoxicity of...

  7. 9 CFR 354.243 - Operations and procedures.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...) The floors in the eviscerating room shall be kept clean and reasonably dry during eviscerating... accord with clean and sanitary methods. (a) There shall be no handling or storing of materials which create an objectionable condition in rooms, compartments, or other places in the plant where any product...

  8. 9 CFR 354.243 - Operations and procedures.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...) The floors in the eviscerating room shall be kept clean and reasonably dry during eviscerating... accord with clean and sanitary methods. (a) There shall be no handling or storing of materials which create an objectionable condition in rooms, compartments, or other places in the plant where any product...

  9. 9 CFR 354.243 - Operations and procedures.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...) The floors in the eviscerating room shall be kept clean and reasonably dry during eviscerating... accord with clean and sanitary methods. (a) There shall be no handling or storing of materials which create an objectionable condition in rooms, compartments, or other places in the plant where any product...

  10. Public-Private Ventures in Bachelor Quarters. A Solution to the Loss of Military Construction Projects. Volume 2. Appendices A through E

    DTIC Science & Technology

    1990-06-01

    appropriated travel funds. For a P/PV BEQ, it is not a user input; the model has an internal industry average value . For a IMILCON BEQ, this would be...has an internal value , and it is not a user input. Rooms Expense: Laundry and Dry Cleaning Any laundry and dry cleaning services to be provided at no...planned rooms and then divided by 365 days, to arrive at the MILCON cost factor for entry into the model. For a P/PV BQ, the model has an internal value

  11. SENSITIVITY ANALYSIS OF THE MULTI-LAYER MODEL USED IN THE CLEAN AIR STATUS AND TRENDS NETWORK (CASTNET)

    EPA Science Inventory

    The U.S. Environmental Protection Agency (EPA) established the Clean Air Status and Trends Network (CASTNET) and its predecessor, the National Dry Deposition Network (NDDN), as national air quality and meteorological monitoring networks. The purpose of CASTNET is to track the pr...

  12. 7 CFR 982.101 - Grade requirements for shelled hazelnuts.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Foreign Material: 0.02 of one percent, for foreign material. (2) For Defects: Five percent for kernels or... or portions of hazelnut kernels shall meet the following requirements: (1) Well dried and clean; (2... firm and crisp, not containing more than 6 percent moisture. (2) Clean means practically free from...

  13. 7 CFR 982.101 - Grade requirements for shelled hazelnuts.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Foreign Material: 0.02 of one percent, for foreign material. (2) For Defects: Five percent for kernels or... or portions of hazelnut kernels shall meet the following requirements: (1) Well dried and clean; (2... firm and crisp, not containing more than 6 percent moisture. (2) Clean means practically free from...

  14. Exposure to Organic Solvents Used in Dry Cleaning Reduces Low and High Level Visual Function

    PubMed Central

    Jiménez Barbosa, Ingrid Astrid

    2015-01-01

    Purpose To investigate whether exposure to occupational levels of organic solvents in the dry cleaning industry is associated with neurotoxic symptoms and visual deficits in the perception of basic visual features such as luminance contrast and colour, higher level processing of global motion and form (Experiment 1), and cognitive function as measured in a visual search task (Experiment 2). Methods The Q16 neurotoxic questionnaire, a commonly used measure of neurotoxicity (by the World Health Organization), was administered to assess the neurotoxic status of a group of 33 dry cleaners exposed to occupational levels of organic solvents (OS) and 35 age-matched non dry-cleaners who had never worked in the dry cleaning industry. In Experiment 1, to assess visual function, contrast sensitivity, colour/hue discrimination (Munsell Hue 100 test), global motion and form thresholds were assessed using computerised psychophysical tests. Sensitivity to global motion or form structure was quantified by varying the pattern coherence of global dot motion (GDM) and Glass pattern (oriented dot pairs) respectively (i.e., the percentage of dots/dot pairs that contribute to the perception of global structure). In Experiment 2, a letter visual-search task was used to measure reaction times (as a function of the number of elements: 4, 8, 16, 32, 64 and 100) in both parallel and serial search conditions. Results Dry cleaners exposed to organic solvents had significantly higher scores on the Q16 compared to non dry-cleaners indicating that dry cleaners experienced more neurotoxic symptoms on average. The contrast sensitivity function for dry cleaners was significantly lower at all spatial frequencies relative to non dry-cleaners, which is consistent with previous studies. Poorer colour discrimination performance was also noted in dry cleaners than non dry-cleaners, particularly along the blue/yellow axis. In a new finding, we report that global form and motion thresholds for dry cleaners were also significantly higher and almost double than that obtained from non dry-cleaners. However, reaction time performance on both parallel and serial visual search was not different between dry cleaners and non dry-cleaners. Conclusions Exposure to occupational levels of organic solvents is associated with neurotoxicity which is in turn associated with both low level deficits (such as the perception of contrast and discrimination of colour) and high level visual deficits such as the perception of global form and motion, but not visual search performance. The latter finding indicates that the deficits in visual function are unlikely to be due to changes in general cognitive performance. PMID:25933026

  15. Surgical wound care - open

    MedlinePlus

    ... your doctor recommends. Hold the syringe 1 to 6 inches (2.5 to 15 centimeters) away from the wound. Spray hard enough into the wound to wash away drainage and discharge. Use a clean soft, dry cloth or piece of gauze to carefully pat the wound dry. ...

  16. Development of Cotton Fabrics with Durable UV Protective and Self-cleaning Property by Deposition of Low TiO2 Levels through Sol-gel Process.

    PubMed

    Mishra, Anu; Butola, Bhupendra Singh

    2018-01-19

    In this article, the deposition of TiO 2 on cotton fabric using sol-gel technique has been described. Various process routes (pad-dry-cure, pad-dry-hydrothermal and pad-dry-solvothermal) were examined to impart a stable coating of TiO 2 on fabric. The role of precursor concentration, process temperature and time of treatment were studied to aim at a wash durable, UV protective and self-cleaning property in the treated fabric. EDX and ICP-MS techniques were used to examine the add-on percentage of TiO 2 on cotton fabrics treated via different routes. It has been found that the TiO 2 remains largely amorphous and nondurable if it is given a short thermal treatment. To convert the deposited TiO 2 to its anatase crystal form, a prolonged hydrothermal treatment for at least 3 h needs to be given. TiO 2 deposition levels of less than 0.1% were found to be effective in imparting reasonable degree of UV protection and self-cleaning property to the cotton fabric. The self-cleaning ability of the treated fabric against coffee stain was also studied and was found to be related to the process route and the deposition levels of TiO 2 . © 2018 The American Society of Photobiology.

  17. Acute Exposure to Perchlorethylene alters Rat Visual Evoked Potentials in Relation to Brain Concentration

    EPA Science Inventory

    These experiments sought to establish a dose-effect relationship between the concentration of perchloroethylene (PCE) in brain tissue and concurrent changes in visual function. A physiologically-based pharmacokinetic (PBPK) model was implemented to predict concentrations of PCE ...

  18. CATALYTIC STEAM REFORMING OF CHLOROCARBONS: METHLYCHLORIDE. (R822721C633)

    EPA Science Inventory

    The effective destruction of trichloroethane, trichloroethylene and perchloroethylene by steam reforming with a commercial nickel catalyst has been demonstrated. Conversion levels of up to 0.99999 were attained in both laboratory and semi-pilot experiments, with the products c...

  19. Occupational exposure to solvents and risk of head and neck cancer in women: a population-based case-control study in France.

    PubMed

    Carton, Matthieu; Barul, Christine; Menvielle, Gwenn; Cyr, Diane; Sanchez, Marie; Pilorget, Corinne; Trétarre, Brigitte; Stücker, Isabelle; Luce, Danièle

    2017-01-09

    Our objective was to investigate the association between head and neck cancer and occupational exposure to chlorinated, oxygenated and petroleum solvents in women. Investigation of occupational and environmental CAuses of REspiratory cancers (ICARE), a French population-based case-control study, included 296 squamous cell carcinomas of the head and neck (HNSCC) in women and 775 female controls. Lifelong occupational history was collected. Job-exposure matrices allowed to assess exposure to 5 chlorinated solvents (carbon tetrachloride; chloroform; methylene chloride; perchloroethylene; trichloroethylene), 5 petroleum solvents (benzene; special petroleum product; gasoline; white spirits and other light aromatic mixtures; diesel, fuels and kerosene) and 5 oxygenated solvents (alcohols; ketones and esters; ethylene glycol; diethyl ether; tetrahydrofuran). OR and 95% CIs, adjusted for smoking, alcohol drinking, age and geographical area, were estimated with logistic models. Elevated ORs were observed among women ever exposed to perchloroethylene (OR=2.97, 95% CI 1.05 to 8.45) and trichloroethylene (OR=2.15, 95% CI 1.21 to 3.81). These ORs increased with exposure duration (OR=3.75, 95% CI 0.64 to 21.9 and OR=4.44, 95% CI 1.56 to 12.6 for 10 years or more, respectively). No significantly increased risk of HNSCC was found for occupational exposure to the other chlorinated, petroleum or oxygenated solvents. These findings suggest that exposure to perchloroethylene or trichloroethylene may increase the risk of HNSCC in women. In our study, there is no clear evidence that the other studied solvents are risk factors for HNSCC. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  20. 40 CFR 721.3 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... providing saleable goods or a service to consumers (e.g., a commercial dry cleaning establishment or..., hoods, chemical goggles, face splash shields, or equivalent eye protection, and various types of respirators. Barrier creams are not included in this definition. Powder or dry solid form means a state where...

  1. 40 CFR 435.11 - Specialized definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... showers, eye-wash stations, hand-wash stations, fish cleaning stations, and galleys located within... formation oil carried out from the wellbore with the drilling fluid. (2) Dry drill cuttings means the... limitations and NSPS means the concentration (milligrams/kilogram dry sediment) of the drilling fluid in...

  2. 7 CFR 58.126 - Buildings.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ..., manufactured, handled, packaged or stored (except dry storage of packaged finished products and supplies) or in... materials not regularly used. (1) Coolers and freezers. Coolers and freezers where dairy products are stored shall be clean, reasonably dry and maintained at the proper uniform temperature and humidity to...

  3. 7 CFR 58.126 - Buildings.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ..., manufactured, handled, packaged or stored (except dry storage of packaged finished products and supplies) or in... materials not regularly used. (1) Coolers and freezers. Coolers and freezers where dairy products are stored shall be clean, reasonably dry and maintained at the proper uniform temperature and humidity to...

  4. 7 CFR 58.126 - Buildings.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ..., manufactured, handled, packaged or stored (except dry storage of packaged finished products and supplies) or in... materials not regularly used. (1) Coolers and freezers. Coolers and freezers where dairy products are stored shall be clean, reasonably dry and maintained at the proper uniform temperature and humidity to...

  5. 7 CFR 58.126 - Buildings.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ..., manufactured, handled, packaged or stored (except dry storage of packaged finished products and supplies) or in... materials not regularly used. (1) Coolers and freezers. Coolers and freezers where dairy products are stored shall be clean, reasonably dry and maintained at the proper uniform temperature and humidity to...

  6. 7 CFR 58.126 - Buildings.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ..., manufactured, handled, packaged or stored (except dry storage of packaged finished products and supplies) or in... materials not regularly used. (1) Coolers and freezers. Coolers and freezers where dairy products are stored shall be clean, reasonably dry and maintained at the proper uniform temperature and humidity to...

  7. Evaluation of Data Replacement Strategies for CASTNET Dry Deposition Modeling

    EPA Science Inventory

    The U.S. Environmental Protection Agency (EPA) established the Clean Air Status and Trends Network (CASTNET) and its predecessor, the National Dry Deposition Network (NDDN), as national air quality and meteorological monitoring networks. The purpose of CASTNET is to track the pr...

  8. IRIS Toxicological Review of Tetrachloroethylene (Perchloroethylene) (External Review Draft)

    EPA Science Inventory

    EPA conducted a peer review of the scientific basis supporting the human health hazard and dose-response assessment of tetrachloroethylene that will appear on the Integrated Risk Information System (IRIS) database. Peer review is meant to ensure that science is used credibly and ...

  9. CATALYTIC STEAM REFORMING OF CHLOROCARBONS: TRICHLOROETHANE, TRICHLOROETHYLENE AND PERCHLOROETHYLENE. (R822721C633)

    EPA Science Inventory

    The perspectives, information and conclusions conveyed in research project abstracts, progress reports, final reports, journal abstracts and journal publications convey the viewpoints of the principal investigator and may not represent the views and policies of ORD and EPA. Concl...

  10. Characterization of uranium surfaces machined with aqueous propylene glycol-borax or perchloroethylene-mineral oil coolants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cristy, S.S.; Bennett, R.K. Jr.; Dillon, J.J.

    1986-12-31

    The use of perchloroethylene (perc) as an ingredient in coolants for machining enriched uranium at the Oak Ridge Y-12 Plant has been discontinued because of environmental concerns. A new coolant was substituted in December 1985, which consists of an aqueous solution of propylene glycol with borax (sodium tetraborate) added as a nuclear poison and with a nitrite added as a corrosion inhibitor. Uranium surfaces machined using the two coolants were compared with respects to residual contamination, corrosion or corrosion potential, and with the aqueous propylene glycol-borax coolant was found to be better than that of enriched uranium machined with themore » perc-mineral oil coolant. The boron residues on the final-finished parts machined with the borax-containing coolant were not sufficient to cause problems in further processing. All evidence indicated that the enriched uranium surfaces machined with the borax-containing coolant will be as satisfactory as those machined with the perc coolant.« less

  11. [Effects of soil and ground water pollution with perchloroethylene from the public health service viewpoint].

    PubMed

    Hauswirth, S

    1990-07-01

    A routine analysis of drinking water conducted in September 1987 in a Rhenish water works revealed a perchloroethylene (PER) content of 3 micrograms/l. Within less than 3 months the concentration in the two northern wells of the entire battery consisting of 4 wells rose to 20 micrograms/l, and hence the complete battery had to be shut off from the water supply network. The pumped-up water was diverted to a draining plant via the precipitation tank of the water works. During the two subsequent months the PER concentration continued to rise, especially in well No. 1, to more than 120 micrograms/l. The present report deals with the measures undertaken to assess the extent of the damage and the effects of the incident on drinking water supply, on the storage of foods in a warehouse, on a planned sewer construction and on the systems installed by various parties for their own water supply, and on wells in private gardens and in a gardening nursery.

  12. New electrostatic coal cleaning method cuts sulfur content by 40%

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1985-12-01

    An emission control system that electrically charges pollutants and coal particles promises to reduce sulfur 40% at half the cost. The dry coal cleaning processes offer superior performance and better economics than conventional flotation cleaning. Advanced Energy Dynamics, Inc. (AED) is developing both fine and ultra fine processes which increase combustion efficiency and boiler reliability and reduced operating costs. The article gives details from the performance tests and comparisons and summarizes the economic analyses. 4 tables.

  13. Facile Dry Surface Cleaning of Graphene by UV Treatment

    NASA Astrophysics Data System (ADS)

    Kim, Jin Hong; Haidari, Mohd Musaib; Choi, Jin Sik; Kim, Hakseong; Yu, Young-Jun; Park, Jonghyurk

    2018-05-01

    Graphene has been considered an ideal material for application in transparent lightweight wearable electronics due to its extraordinary mechanical, optical, and electrical properties originating from its ordered hexagonal carbon atomic lattice in a layer. Precise surface control is critical in maximizing its performance in electronic applications. Graphene grown by chemical vapor deposition is widely used but it produces polymeric residue following wet/chemical transfer process, which strongly affects its intrinsic electrical properties and limits the doping efficiency by adsorption. Here, we introduce a facile dry-cleaning method based on UV irradiation to eliminate the organic residues even after device fabrication. Through surface topography, Raman analysis, and electrical transport measurement characteristics, we confirm that the optimized UV treatment can recover the clean graphene surface and improve graphene-FET performance more effectively than thermal treatment. We propose our UV irradiation method as a systematically controllable and damage-free post process for application in large-area devices.

  14. 75 FR 45109 - Kern River Gas Transmission Company; Notice of Availability of the Final Environmental Impact...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-02

    ... the Dry Lake Compressor Station located in Clark County, Nevada; Six mainline valves; and Three pig \\2\\ launcher and two pig receiver facilities. \\2\\ A pig is an internal tool that can be used to clean and dry a...

  15. Estimates of the atmospheric deposition of sulfur and nitrogen species: Clean Air Status and Trends Network 1990-2000.

    PubMed

    Baumgardner, Ralph E; Lavery, Thomas F; Rogers, Christopher M; Isil, Selma S

    2002-06-15

    The Clean Air Status and Trends Network (CASTNet) was established by the U.S. EPA in response to the requirements of the 1990 Clean Air Act Amendments. To satisfy these requirements CASTNet was designed to assess and report on geographic patterns and long-term, temporal trends in ambient air pollution and acid deposition in order to gauge the effectiveness of current and future mandated emission reductions. This paper presents an analysis of the spatial patterns of deposition of sulfur and nitrogen pollutants for the period 1990-2000. Estimates of deposition are provided for two 4-yr periods: 1990-1993 and 1997-2000. These two periods were selected to contrast deposition before and after the large decrease in SO2 emissions that occurred in 1995. Estimates of dry deposition were obtained from measurements at CASTNet sites combined with deposition velocities that were modeled using the multilayer model, a 20-layer model that simulates the various atmospheric processes that contribute to dry deposition. Estimates of wet deposition were obtained from measurements at sites operated bythe National Atmospheric Deposition Program. The estimates of dry and wet deposition were combined to calculate total deposition of atmospheric sulfur (dry SO2, dry and wet SO4(2-)) and nitrogen (dry HNO3, dry and wet NO3-, dry and wet NH4+). An analysis of the deposition estimates showed a significant decline in sulfur deposition and no change in nitrogen deposition. The highest rates of sulfur deposition were observed in the Ohio River Valley and downwind states. This region also observed the largest decline in sulfur deposition. The highest rates of nitrogen deposition were observed in the Midwest from Illinois to southern New York State. Sulfur and nitrogen deposition fluxes were significantly higher in the eastern United States as compared to the western sites. Dry deposition contributed approximately 38% of total sulfur deposition and 30% of total nitrogen deposition in the eastern United States. Percentages are similar for the two 4-yr periods. Wet sulfate and dry SO2 depositions were the largest contributors to sulfur deposition. Wet nitrate, wet ammonium, and dry HNO3 depositions were the largest contributors to nitrogen deposition.

  16. Cross-sectional study of frequency and factors associated with stethoscope cleaning among medical practitioners in Pakistan.

    PubMed

    Hyder, O

    2012-07-01

    Stethoscope diaphragms are frequently colonized by bacteria. This cross-sectional study described the frequency and factors associated with reporting ever cleaning stethoscopes among 408 medical students and doctors at a medical college and 2 teaching hospitals in Rawalpindi, Pakistan. A minority of the respondents (37.7%) reported having ever cleaned their stethoscope. Following normal clinical use, wiping with a dry cloth was the most frequently reported method of cleaning (53.2%). After contamination of the diaphragm with blood or secretions, cleaning with an alcoholic swab was the most common method (64.3%). In univariate and multivariate analyses, history of receiving information on stethoscope cleaning, utilization of personal stethoscope at last use and affiliation with internal medicine department were factors strongly associated with ever cleaning of stethoscope. Future research for improving stethoscope cleaning practices should explore educational interventions aimed at health care professionals.

  17. PROPERTY CHANGES IN AQUEOUS SOLUTIONS DUE TO SURFACTANT TREATMENT OF PCE: IMPLICATIONS TO GEOPHYSICAL MEASUREMENTS

    EPA Science Inventory

    Select physicochemical properties of aqueous solutions composed of surfactants, dye, and

    perchloroethylene (PCE) were evaluated through a response surface quadratic design

    model of experiment. Nine surfactants, which are conventionally used in the

    remediation...

  18. INHIBITION OF HUMAN A7 NEURONAL NICOTINIC ACETYLCHOLINE RECEPTORS BY THE VOLATILE ORGANIC SOLVENT TRICHLOROETHYLENE.

    EPA Science Inventory

    Volatile organic compounds such as toleune, trichloroethylene and perchloroethylene are potent and reversible blockers of voltage-gated calcium current in nerve growth factor (NGF)-differentiated pheochromocytoma (PC12) cells. It is hypothesized that effects of VOCs on ICa contri...

  19. 40 CFR 63.320 - Applicability.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (10 tons per year) of perchloroethylene to the atmosphere. In lieu of measuring a facility's potential...) per year. Consumption is determined according to § 63.323(d). (e) Each existing transfer machine... gallons) per year. Consumption is determined according to § 63.323(d). (f) If the total yearly...

  20. 40 CFR 63.320 - Applicability.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (10 tons per year) of perchloroethylene to the atmosphere. In lieu of measuring a facility's potential...) per year. Consumption is determined according to § 63.323(d). (e) Each existing transfer machine... gallons) per year. Consumption is determined according to § 63.323(d). (f) If the total yearly...

  1. CONTROLLED RELEASE, BLIND TEST OF DNAPL REMEDIATION BY ETHANOL FLUSHING

    EPA Science Inventory

    A dense nonaqueous phase liquid (DNAPL) source zone was established within a sheet-pile
    isolated cell through a controlled release of perchloroethylene (PCE) to evaluate DNAPL
    remediation by in-situ cosolvent flushing. Ethanol was used as the cosolvent, and the main remedia...

  2. Using a peanut drying monitoring system to estimate costs of nonbeneficial dryer operation

    USDA-ARS?s Scientific Manuscript database

    Presently, the peanut industry lacks a commercially available, industry-accepted solution for real-time kernel moisture content determination during peanut drying. Samples of unshelled peanuts are extracted from the semitrailer by an operator periodically, and the samples have to be cleaned and shel...

  3. Prevalence of dry eye syndrome after a three-year exposure to a clean room.

    PubMed

    Cho, Hyun A; Cheon, Jae Jung; Lee, Jong Seok; Kim, Soo Young; Chang, Seong Sil

    2014-01-01

    To measure the prevalence of dry eye syndrome (DES) among clean room (relative humidity ≤1%) workers from 2011 to 2013. Three annual DES examinations were performed completely in 352 clean room workers aged 20-40 years who were working at a secondary battery factory. Each examination comprised the tear-film break-up test (TFBUT), Schirmer's test I, slit-lamp microscopic examination, and McMonnies questionnaire. DES grades were measured using the Delphi approach. The annual examination results were analyzed using a general linear model and post-hoc analysis with repeated-ANOVA (Tukey). Multiple logistic regression was performed using the examination results from 2013 (dependent variable) to analyze the effect of years spent working in the clean room (independent variable). The prevalence of DES among these workers was 14.8% in 2011, 27.1% in 2012, and 32.8% in 2013. The TFBUT and McMonnies questionnaire showed that DES grades worsened over time. Multiple logistic regression analysis indicated that the odds ratio for having dry eyes was 1.130 (95% CI 1.012-1.262) according to the findings of the McMonnies questionnaire. This 3-year trend suggests that the increased prevalence of DES was associated with longer working hours. To decrease the prevalence of DES, employees should be assigned reasonable working hours with shift assignments that include appropriate break times. Workers should also wear protective eyewear, subdivide their working process to minimize exposure, and utilize preservative-free eye drops.

  4. NESDI FY10 Year in Review Report: The Case For Success 2010

    DTIC Science & Technology

    2010-01-01

    36 CASE STUDY: Motion Assisted Environmental Enclosure for Capturing Paint Overspray in Dry Docks...and to outline a means to assess its environmental impact. 8. Motion Assisted Environmental Enclosure for Capturing Paint Overspray in Dry Docks...in dry docks. 9. Cleaning Solvents for the 21st Century. As part of the Department of Defense’s (DoD) response to eliminating the use of volatile

  5. Cleaning procedure for improved photothermal background of toroidal optical microresonators

    NASA Astrophysics Data System (ADS)

    Horak, Erik H.; Knapper, Kassandra A.; Heylman, Kevin D.; Goldsmith, Randall H.

    2016-09-01

    High Q-factors and small mode volumes have made toroidal optical microresonators exquisite sensors to small shifts in the effective refractive index of the WGM modes. Eliminating contaminants and improving quality factors is key for many different sensing techniques, and is particularly important for photothermal imaging as contaminants add photothermal background obscuring objects of interest. Several different cleaning procedures including wet- and dry-chemical procedures are tested for their effect on Q-factors and photothermal background. RCA cleaning was shown to be successful in contrast to previously described acid cleaning procedures, most likely due to the different surface reactivity of the acid reagents used. UV-ozone cleaning was shown to be vastly superior to O2 plasma cleaning procedures, significantly reducing the photothermal background of the resonator.

  6. 40 CFR Appendix 7 to Subpart A of... - API Recommended Practice 13B-2

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... facilitate cleaning and funnel-shaped top to catch falling drops. For compliance monitoring under the NPDES... condenser. b. Pack the retort body with steel wool. c. Apply lubricant/sealant to threads of retort cup and... the clean and dry liquid receiver. This is mass (C), grams. Place the receiver below condenser outlet...

  7. 40 CFR Appendix 7 to Subpart A of... - API Recommended Practice 13B-2

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... facilitate cleaning and funnel-shaped top to catch falling drops. For compliance monitoring under the NPDES... condenser. b. Pack the retort body with steel wool. c. Apply lubricant/sealant to threads of retort cup and... the clean and dry liquid receiver. This is mass (C), grams. Place the receiver below condenser outlet...

  8. CHARACTERIZATION OF THE EFFECTS OF INHALED PERCHLOROETHYLENE ON SUSTAINED ATTENTION IN RATS PERFORMING A VISUAL SIGNAL DETECTION TASK

    EPA Science Inventory

    The aliphatic hydrocarbon perchloroethyelene (PCE) has been associated with neurobehavioral dysfunction including reduced attention in humans. The current study sought to assess the effects of inhaled PCE on sustained attention in rats performing a visual signal detection task (S...

  9. EXTRACTION AND QUANTITATIVE ANALYSIS OF ELEMENTAL SULFUR FROM SULFIDE MINERAL SURFACES BY HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY. (R826189)

    EPA Science Inventory

    A simple method for the quantitative determination of elemental sulfur on oxidized sulfide minerals is described. Extraction of elemental sulfur in perchloroethylene and subsequent analysis with high-performance liquid chromatography were used to ascertain the total elemental ...

  10. Health-hazard evaluation report HETA 86-005-1679, Dutch Girl Cleaners, Springdale, Ohio

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burr, G.A.; Todd, W.

    1986-03-01

    An environmental survey at Dutch Girl Cleaners in the Thriftway Mini Mall, Springdale, Ohio, was conducted on October 25, 1985, and air samples collected on October 30, 1985 from the cleaners, an adjacent supermarket and the enclosed pedestrian mall were analyzed for perchloroethylene.

  11. IRIS TOXICOLOGICAL REVIEW AND SUMMARY DOCUMENTS FOR TETRACHLOROETHYLENE

    EPA Science Inventory

    The known toxic effects of perchloroethylene will be summarized, with citations from current scientific literature. The critical effects will be identified, and from this the RfD and RfC and cancer unit risk factors will be derived. The RfD and RfC are reference doses and air c...

  12. The efficacy of different cleaning and disinfection procedures to reduce Salmonella and Enterobacteriaceae in the lairage environment of a pig abattoir.

    PubMed

    Walia, Kavita; Argüello, Hector; Lynch, Helen; Grant, Jim; Leonard, Finola C; Lawlor, Peadar G; Gardiner, Gillian E; Duffy, Geraldine

    2017-04-04

    This study investigated several cleaning and disinfection protocols for their ability to eliminate Salmonella and to reduce levels of Enterobacteriaceae, within the lairage pens of a commercial pig abattoir. Eight protocols were evaluated in each of 12 lairage pens at the end of the slaughtering day on 3 occasions (36 pens/protocol): (P1) high-pressure cold water wash (herein referred to as high-pressure wash); (P2) high-pressure wash followed by a quaternary ammonium compound (QAC)-based disinfectant without rinsing; (P3) high-pressure wash followed by a chlorocresol-based disinfectant without rinsing; (P4) high-pressure wash followed by a sodium hydroxide/sodium hypochlorite detergent with rinsing; (P5) P4 followed by P2; (P6) P4 followed by P3; (P7) P5 with drying for 24-48h; and (P8) P6 with drying for 24-48h. Two floor swabs and one wall swab were taken from each lairage pen before and after each protocol was applied, and examined for the presence of Salmonella and enumeration of Enterobacteriaceae. High-pressure washing alone (P1) did not reduce the prevalence of Salmonella in the lairage pens. When high-pressure washing, the probability of detecting Salmonella following application of the chlorocresol-based disinfectant (P3) was lower than with the QAC-based disinfectant, P2 (14.2% versus 34.0%, respectively; p<0.05). The probability of detecting Salmonella after the combined use of detergent and the chlorocresol-based disinfectant (P6) was also lower than application of detergent followed by the QAC-based disinfectant, P5 (2.2% versus 17.1%, respectively; p<0.05). Drying of pens (P7 and P8) greatly reduced the probability of detecting Salmonella. Only 3.8% of swabs were Salmonella-positive 48h after cleaning with detergent and the QAC-based disinfectant (P7); while an eradication of Salmonella was achieved 24h after cleaning with detergent and the chlorocresol-based disinfectant, P8. A reduction in Enterobacteriaceae counts to below the limit of detection (LOD; 10CFU/cm 2 ) was achieved following cleaning with detergent and disinfection with the chlorocresol-based disinfectant, regardless of drying (p<0.05), whereas, applying detergent and the QAC-based disinfectant (P7) did not reduce Enterobacteriaceae counts to below the LOD. Therefore ensuring that lairage pens are allowed to dry after intensive cleaning with detergent and a chlorocresol-based disinfectant is recommended as the most effective hygiene routine to eliminate Salmonella and reduce Enterobacteriaceae counts. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Air Emissions Inventory Guidance Document for Stationary Sources at Air Force Installations.

    DTIC Science & Technology

    1999-05-01

    small stoker-fired boilers). sox Change to lower sulfur coal, Coal Cleaning, Flue Gas Desulfurization (e.g., wet scrubbing, spray drying, furnace...Multiclone Collector. SOx Flue Gas Desulfurization (e.g., wet , semi-dry, or dry scrubbers) NOx Low Excess Air, Burners out of Service, Biased Burner...both flue gas desulfurization spray dryer adsorber (FGD-SDA) and a fabric filter (FF). d Factors apply to boilers equipped with an electrostatic

  14. 9 CFR 590.548 - Drying, blending, packaging, and heat treatment rooms and facilities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 2 2011-01-01 2011-01-01 false Drying, blending, packaging, and heat..., blending, packaging, and heat treatment rooms and facilities. (a) General. Processing rooms shall be... vacuum cleaned daily. (c) The heat treatment room shall be of an approved construction and be maintained...

  15. 9 CFR 590.548 - Drying, blending, packaging, and heat treatment rooms and facilities.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 9 Animals and Animal Products 2 2013-01-01 2013-01-01 false Drying, blending, packaging, and heat..., blending, packaging, and heat treatment rooms and facilities. (a) General. Processing rooms shall be... vacuum cleaned daily. (c) The heat treatment room shall be of an approved construction and be maintained...

  16. 9 CFR 590.548 - Drying, blending, packaging, and heat treatment rooms and facilities.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 9 Animals and Animal Products 2 2012-01-01 2012-01-01 false Drying, blending, packaging, and heat..., blending, packaging, and heat treatment rooms and facilities. (a) General. Processing rooms shall be... vacuum cleaned daily. (c) The heat treatment room shall be of an approved construction and be maintained...

  17. 9 CFR 590.548 - Drying, blending, packaging, and heat treatment rooms and facilities.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 9 Animals and Animal Products 2 2014-01-01 2014-01-01 false Drying, blending, packaging, and heat..., blending, packaging, and heat treatment rooms and facilities. (a) General. Processing rooms shall be... vacuum cleaned daily. (c) The heat treatment room shall be of an approved construction and be maintained...

  18. Influence of defoliation date and gin-drying temperature on oven moisture and KFT water within cotton cultivars

    USDA-ARS?s Scientific Manuscript database

    Water measured in lint cotton by Karl Fischer Titration was compared to moisture content measured by standard oven-drying in two cultivars. The cultivars had been defoliated at different times and ginned at two possible temperatures. Ginned lint was further processed to produce mechanically cleaned,...

  19. 40 CFR 63.322 - Standards.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... at each opening at all times that the machine is operating. (b) The owner or operator of each new dry... articles to or from the machine, and shall keep the door closed at all other times. (d) The owner or... existing dry cleaning system and of each new transfer machine system and its ancillary equipment installed...

  20. 40 CFR 63.322 - Standards.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... at each opening at all times that the machine is operating. (b) The owner or operator of each new dry... articles to or from the machine, and shall keep the door closed at all other times. (d) The owner or... existing dry cleaning system and of each new transfer machine system and its ancillary equipment installed...

  1. Laser cutting eliminates nucleic acid cross-contamination in dried-blood-spot processing.

    PubMed

    Murphy, Sean C; Daza, Glenda; Chang, Ming; Coombs, Robert

    2012-12-01

    Dried blood spots (DBS) are useful for molecular assays but are prone to false positives from cross-contamination. In our malaria DBS assay, cross-contamination was encountered despite cleaning techniques suitable for HIV-1. We therefore developed a contact-free laser cutting system that effectively eliminated cross-contamination during DBS processing.

  2. SEASONAL AND REGIONAL AIR QUALITY AND ATMOSPHERIC DEPOSITION IN THE EASTERN US

    EPA Science Inventory

    Dry concentration and dry and wet deposition of selected air pollutants monitored over two 5-year periods in the 1990s at or near 34 rural Clean Air Status and Trends Network (CASTNET) sites located in the eastern US are adjusted for known biases, composed into seasonal values, a...

  3. Preparation and combustion of Yugoslavian lignite-water fuel, Task 7.35. Topical report, July 1991--December 1993

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anderson, C.M.; DeWall, R.A.; Ljubicic, B.R.

    1994-03-01

    Yugoslavia`s interest in lignite-water fuel (LWF) stems from its involvement in an unusual power project at Kovin in northern Serbia. In the early 1980s, Electric Power of Serbia (EPS) proposed constructing a 600-MW power plant that would be fueled by lignite found in deposits along and under the Danube River. Trial underwater mining at Kovin proved that the dredging operation is feasible. The dredging method produces a coal slurry containing 85% to 90% water. Plans included draining the water from the coal, drying it, and then burning it in the pulverized coal plant. In looking for alternative ways to utilizemore » the ``wet coal`` in a more efficient and economical way, a consortium of Yugoslavian companies agreed to assess the conversion of dredged lignite into a LWF using hot-water-drying (HWD) technology. HWD is a high-temperature, nonevaporative drying technique carried out under high pressure in water that permanently alters the structure of low-rank coals. Changes effected by the drying process include irreversible removal of moisture, micropore sealing by tar, and enhancement of heating value by removal of oxygen, thus, enhancement of the slurry ability of the coal with water. Physical cleaning results indicated a 51 wt % reduction in ash content with a 76 wt % yield for the lignite. In addition, physical cleaning produced a cleaned slurry that had a higher attainable solids loading than a raw uncleaned coal slurry. Combustion studies were then performed on the raw and physically cleaned samples with the resulting indicating that both samples were very reactive, making them excellent candidates for HWD. Bench-scale results showed that HWD increased energy densities of the two raw lignite samples by approximately 63% and 81%. An order-of-magnitude cost estimate was conducted to evaluate the HWD and pipeline transport of Kovin LWF to domestic and export European markets. Results are described.« less

  4. Prevalence of Dry Eye Syndrome after a Three-Year Exposure to a Clean Room

    PubMed Central

    2014-01-01

    Objective To measure the prevalence of dry eye syndrome (DES) among clean room (relative humidity ≤1%) workers from 2011 to 2013. Methods Three annual DES examinations were performed completely in 352 clean room workers aged 20–40 years who were working at a secondary battery factory. Each examination comprised the tear-film break-up test (TFBUT), Schirmer’s test I, slit-lamp microscopic examination, and McMonnies questionnaire. DES grades were measured using the Delphi approach. The annual examination results were analyzed using a general linear model and post-hoc analysis with repeated-ANOVA (Tukey). Multiple logistic regression was performed using the examination results from 2013 (dependent variable) to analyze the effect of years spent working in the clean room (independent variable). Results The prevalence of DES among these workers was 14.8% in 2011, 27.1% in 2012, and 32.8% in 2013. The TFBUT and McMonnies questionnaire showed that DES grades worsened over time. Multiple logistic regression analysis indicated that the odds ratio for having dry eyes was 1.130 (95% CI 1.012–1.262) according to the findings of the McMonnies questionnaire. Conclusions This 3-year trend suggests that the increased prevalence of DES was associated with longer working hours. To decrease the prevalence of DES, employees should be assigned reasonable working hours with shift assignments that include appropriate break times. Workers should also wear protective eyewear, subdivide their working process to minimize exposure, and utilize preservative-free eye drops. PMID:25339991

  5. Effects of trichloroethylene and perchloroethylene on wild rodents at Edwards Air Force Base, California, USA

    USGS Publications Warehouse

    Spring, Sarah E.; Miles, A. Keith; Anderson, Michael J.

    2004-01-01

    Effects of inhalation of volatilized trichloroethylene (TCE) or perchloroethylene (PCE) were assessed based on the health and population size of wild, burrowing mammals at Edwards Air Force Base (CA, USA). Organic soil-vapor concentrations were measured at three sites with aquifer contamination of TCE or PCE of 5.5 to 77 mg/L and at two uncontaminated reference sites. Population estimates of kangaroo rats (Dipodomys merriami and D. panamintinus) as well as hematology, blood chemistry, and histopathology of kangaroo rats and deer mice (Peromyscus maniculatus) were compared between contaminated and uncontaminated populations. Maximum soil-gas concentrations associated with groundwater contamination were less than 1.5 μl/L of TCE and 0.07 μl/L of PCE. Population estimates of kangaroo rats were similar at contaminated and reference sites. Hematology, blood chemistry, and histopathology of kangaroo rats and deer mice indicated no evidence of health effects caused by exposure. Trichloroethylene or PCE in groundwater and in related soil gas did not appear to reduce the size of small mammal populations or impair the health of individuals.

  6. Thermocatalytic Destruction of Gas-Phase Perchloroethylene Using Propane as a Hydrogen Source

    PubMed Central

    Willinger, Marty; Rupp, Erik; Barbaris, Brian; Gao, Song; Arnolda, Robert; Betterton, Eric; Sáez, A. Eduardo

    2009-01-01

    The use of propane in combination with oxygen to promote the destruction of perchloroethylene (PCE) over a platinum (Pt)/rhodium (Rh) catalyst on a cerium/zirconium oxide washcoat supported on an alumina monolith was explored. Conversions of PCE were measured in a continuous flow reactor with residence times less than 0.5 s and temperatures ranging from 200 to 600°C. The presence of propane was shown to increase significantly the conversion of PCE over oxygen-only conditions. Conversions close to 100% were observed at temperatures lower than 450°C with 20% oxygen and 2% propane in the feed, which makes this process attractive from a practical standpoint. In the absence of oxygen, PCE conversion is even higher, but the catalyst suffers significant deactivation in less than an hour. Even though results show that oxygen competes with reactants for active sites on the catalyst, the long-term stability that oxygen confers to the catalyst makes the process an efficient alternative to PCE oxidation. A Langmuir-Hinshelwood competitive adsorption model is proposed to quantify PCE conversion. PMID:19217713

  7. Drying Milk With Boiler Exhaust

    NASA Technical Reports Server (NTRS)

    Broussard, M. R.

    1984-01-01

    Considerable energy saved in powdered-milk industry. Only special requirement boiler fired with natural gas or other clean fuel. Boiler flue gas fed to spray drier where it directly contacts product to be dried. Additional heat supplied by auxillary combustor when boiler output is low. Approach adaptable to existing plants with minimal investment because most already equipped with natural-gas-fired boilers.

  8. 40 CFR 63.4765 - How do I determine the emission capture system efficiency?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... coating, curing, and drying occurs within the capture system; and the removal or evaporation of cleaning... criterion is not met if parts enter the open shop environment when being moved between a spray booth and a... activities and drying or curing time. (c) Liquid-to-uncaptured-gas protocol using a temporary total enclosure...

  9. Laser Cutting Eliminates Nucleic Acid Cross-Contamination in Dried-Blood-Spot Processing

    PubMed Central

    Daza, Glenda; Chang, Ming; Coombs, Robert

    2012-01-01

    Dried blood spots (DBS) are useful for molecular assays but are prone to false positives from cross-contamination. In our malaria DBS assay, cross-contamination was encountered despite cleaning techniques suitable for HIV-1. We therefore developed a contact-free laser cutting system that effectively eliminated cross-contamination during DBS processing. PMID:23052309

  10. CONCENTRATION OF TETRACHLOROETHYLENE IN INDOOR AIR AT A FORMER DRY CLEANER FACILITY AS A FUNCTION OF SUBSURFACE CONTAMINATION: A CASE STUDY

    EPA Science Inventory

    A field study was performed to evaluate indoor air concentrations and vapor intrusion (VI) of tetrachloroethylene (PCE) and other chlorinated solvents at a commercial retail site in Dallas, TX. The building is approximately 40 years old and once housed a dry cleaning operation. R...

  11. Occupational exposures and mammographic density in Spanish women.

    PubMed

    Lope, Virginia; García-Pérez, Javier; Pérez-Gómez, Beatriz; Pedraza-Flechas, Ana María; Alguacil, Juan; González-Galarzo, Mª Carmen; Alba, Miguel Angel; van der Haar, Rudolf; Cortés-Barragán, Rosa Ana; Pedraz-Pingarrón, Carmen; Moreo, Pilar; Santamariña, Carmen; Ederra, María; Vidal, Carmen; Salas-Trejo, Dolores; Sánchez-Contador, Carmen; Llobet, Rafael; Pollán, Marina

    2018-02-01

    The association between occupational exposures and mammographic density (MD), a marker of breast cancer risk, has not been previously explored. Our objective was to investigate the influence of occupational exposure to chemical, physical and microbiological agents on MD in adult women. This is a population-based cross-sectional study based on 1476 female workers aged 45-65 years from seven Spanish breast cancer screening programmes. Occupational history was surveyed by trained staff. Exposure to occupational agents was assessed using the Spanish job-exposure matrix MatEmESp. Percentage of MD was measured by two radiologists using a semiautomatic computer tool. The association was estimated using mixed log-linear regression models adjusting for age, education, body mass index, menopausal status, parity, smoking, alcohol intake, type of mammography, family history of breast cancer and hormonal therapy use, and including screening centre and professional reader as random effects terms. Although no association was found with most of the agents, women occupationally exposed to perchloroethylene (e β =1.51; 95% CI 1.04 to 2.19), ionising radiation (e β =1.23; 95% CI 0.99 to 1.52) and mould spores (e β =1.44; 95% CI 1.01 to 2.04) tended to have higher MD. The percentage of density increased 12% for every 5 years exposure to perchloroethylene or mould spores, 11% for every 5 years exposure to aliphatic/alicyclic hydrocarbon solvents and 3% for each 5 years exposure to ionising radiation. Exposure to perchloroethylene, ionising radiation, mould spores or aliphatic/alicyclic hydrocarbon solvents in occupational settings could be associated with higher MD. Further studies are needed to clarify the accuracy and the reasons for these findings. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  12. Dry ice blasting

    NASA Astrophysics Data System (ADS)

    Lonergan, Jeffrey M.

    1992-04-01

    As legal and societal pressures against the use of hazardous waste generating materials has increased, so has the motivation to find safe, effective, and permanent replacements. Dry ice blasting is a technology which uses CO2 pellets as a blasting medium. The use of CO2 for cleaning and stripping operations offers potential for significant environmental, safety, and productivity improvements over grit blasting, plastic media blasting, and chemical solvent cleaning. Because CO2 pellets break up and sublime upon impact, there is no expended media to dispose of. Unlike grit or plastic media blasting which produce large quantities of expended media, the only waste produced by CO2 blasting is the material removed. The quantity of hazardous waste produced, and thus the cost of hazardous waste disposal is significantly reduced.

  13. Sanitizing in Dry-Processing Environments Using Isopropyl Alcohol Quaternary Ammonium Formula.

    PubMed

    Kane, Deborah M; Getty, Kelly J K; Mayer, Brian; Mazzotta, Alejandro

    2016-01-01

    Dry-processing environments are particularly challenging to clean and sanitize because introduced water can favor growth and establishment of pathogenic microorganisms such as Salmonella. Our objective was to determine the efficacy of an isopropyl alcohol quaternary ammonium (IPAQuat) formula for eliminating potential Salmonella contamination on food contact surfaces. Clean stainless steel coupons and conveyor belt materials used in dry-processing environments were spot inoculated in the center of coupons (5 by 5 cm) with a six-serotype composite of Salmonella (approximately 10 log CFU/ml), subjected to IPAQuat sanitizer treatments with exposure times of 30 s, 1 min, or 5 min, and then swabbed for enumeration of posttreatment survivors. A subset of inoculated surfaces was soiled with a breadcrumb-flour blend and allowed to sit on the laboratory bench for a minimum of 16 h before sanitation. Pretreatment Salmonella populations (inoculated controls, 0 s treatment) were approximately 7.0 log CFU/25 cm(2), and posttreatment survivors were 1.31, 0.72, and < 0.7 (detection limit) log CFU/25 cm(2) after sanitizer exposure for 30 s, 1 min, or 5 min, respectively, for both clean (no added soil) and soiled surfaces. Treatment with the IPAQuat formula using 30-s sanitizer exposures resulted in 5.68-log reductions, whereas >6.0-log reductions were observed for sanitizer exposures of 1 and 5 min. Because water is not introduced into the processing environment with this approach, the IPAQuat formula could have sanitation applications in dry-processing environments to eliminate potential contamination from Salmonella on food contact surfaces.

  14. The effect of an instant hand sanitizer on blood glucose monitoring results.

    PubMed

    Mahoney, John J; Ellison, John M; Glaeser, Danielle; Price, David

    2011-11-01

    People with diabetes mellitus are instructed to clean their skin prior to self-monitoring of blood glucose to remove any dirt or food residue that might affect the reading. Alcohol-based hand sanitizers have become popular when soap and water are not available. The aim of this study was to determine whether a hand sanitizer is compatible with glucose meter testing and effective for the removal of exogenous glucose. We enrolled 34 nonfasting subjects [14 male/20 female, mean ages 45 (standard deviation, 9.4)] years, 2 with diagnosed diabetes/32 without known diabetes]. Laboratory personnel prepared four separate fingers on one hand of each subject by (1) cleaning the second finger with soap and water and towel drying (i.e., control finger), (2) cleaning the third finger with an alcohol-based hand sanitizer, (3) coating the fourth finger with cola and allowing it to air dry, and (4) coating the fifth finger with cola and then cleaning it with the instant hand sanitizer after the cola had dried. Finger sticks were performed on each prepared finger and blood glucose was measured. Several in vitro studies were also performed to investigate the effectiveness of the hand sanitizer for removal of exogenous glucose.z Mean blood glucose values from fingers cleaned with instant hand sanitizer did not differ significantly from the control finger (p = .07 and .08, respectively) and resulted in 100% accurate results. Blood glucose data from the fourth (cola-coated) finger were substantially higher on average compared with the other finger conditions, but glucose data from the fifth finger (cola-coated then cleaned with hand sanitizer) was similar to the control finger. The data from in vitro experiments showed that the hand sanitizer did not adversely affect glucose meter results, but when an exogenous glucose interference was present, the effectiveness of the hand sanitizer on glucose bias (range: 6% to 212%) depended on the surface area and degree of dilution. In our study, use of an instant hand sanitizer was compatible with the results of a blood glucose monitor and did not affect finger stick blood glucose results. However, depending on surface area, hand sanitizers may not be adequate for cleaning the skin prior to glucose meter testing. © 2011 Diabetes Technology Society.

  15. The Effect of an Instant Hand Sanitizer on Blood Glucose Monitoring Results

    PubMed Central

    Mahoney, John J; Ellison, John M; Glaeser, Danielle; Price, David

    2011-01-01

    Background People with diabetes mellitus are instructed to clean their skin prior to self-monitoring of blood glucose to remove any dirt or food residue that might affect the reading. Alcohol-based hand sanitizers have become popular when soap and water are not available. The aim of this study was to determine whether a hand sanitizer is compatible with glucose meter testing and effective for the removal of exogenous glucose. Methods We enrolled 34 nonfasting subjects [14 male/20 female, mean ages 45 (standard deviation, 9.4)] years, 2 with diagnosed diabetes/32 without known diabetes]. Laboratory personnel prepared four separate fingers on one hand of each subject by (1) cleaning the second finger with soap and water and towel drying (i.e., control finger), (2) cleaning the third finger with an alcohol-based hand sanitizer, (3) coating the fourth finger with cola and allowing it to air dry, and (4) coating the fifth finger with cola and then cleaning it with the instant hand sanitizer after the cola had dried. Finger sticks were performed on each prepared finger and blood glucose was measured. Several in vitro studies were also performed to investigate the effectiveness of the hand sanitizer for removal of exogenous glucose.z Results Mean blood glucose values from fingers cleaned with instant hand sanitizer did not differ significantly from the control finger (p = .07 and .08, respectively) and resulted in 100% accurate results. Blood glucose data from the fourth (cola-coated) finger were substantially higher on average compared with the other finger conditions, but glucose data from the fifth finger (cola-coated then cleaned with hand sanitizer) was similar to the control finger. The data from in vitro experiments showed that the hand sanitizer did not adversely affect glucose meter results, but when an exogenous glucose interference was present, the effectiveness of the hand sanitizer on glucose bias (range: 6% to 212%) depended on the surface area and degree of dilution. Conclusions In our study, use of an instant hand sanitizer was compatible with the results of a blood glucose monitor and did not affect finger stick blood glucose results. However, depending on surface area, hand sanitizers may not be adequate for cleaning the skin prior to glucose meter testing. PMID:22226262

  16. Commercial tree regeneration 6 years after high-intensity burns in a seasonally dry forest in Bolivia

    Treesearch

    Deborah Kennard

    2004-01-01

    The effects of three site-preparation treatments (high-intensity burn, low-intensity burn, and mechanical cleaning with machetes and chainsaws) on the regeneration of commercial tree species, composition and structure of competing vegetation, and soil chemical and structural properties were evaluated in a seasonally dry forest in southeast Bolivia. Six years after...

  17. Should whole-tree chips for fuel be dried before storage?

    Treesearch

    E. L. Springer

    1979-01-01

    Whole-tree chips deteriorate more rapidly than do clean, debarked chips and present a greater hazard for spontaneous ignition when stored in outdoor piles. To prevent ignition, the chips can be stored for only short periods of time and the frequent rotation of the storage piles results in high handling costs. Drying the chips prior to storage will prevent deterioration...

  18. Colour changes by laser irradiation of reddish building limestones

    NASA Astrophysics Data System (ADS)

    Grossi, C. M.; Benavente, D.

    2016-10-01

    We have used X-ray photoelectron spectroscopy (XPS) as a novel method to investigate the causes of colour changes in a reddish limestone under irradiation by a Q-switched Nd:YAG 1064 nm laser. We irradiated clean dry and wet surfaces of Pidramuelle Roja, a building stone frequently used in the Asturian heritage, at fluences ranging from 0.12 to 1.47 J cm-2. We measured the colour coordinates and undertook XPS analysis of the state of oxidation of iron both before and after irradiation. Visible colour changes and potential aesthetic damage occurred on dry surfaces from a fluence of 0.31 J cm-2, with the stone showing a greening effect and very intense darkening. The colour change on dry surfaces was considerably higher than on wet surfaces, which at the highest fluence (1.47 J cm-2) was also above the human visual detection threshold. The use of XPS demonstrated that the change in colour (chroma and hue) is associated with a reduction in the iron oxidation state on dry surfaces during laser irradiation. This points out to a potential routinary use of XPS to analyse causes of colour changes during laser cleaning in other types of coloured building stones.

  19. Processes For Cleaning a Cathode Tube and Assemblies In A Hollow Cathode Assembly

    NASA Technical Reports Server (NTRS)

    Patterson, Michael J. (Inventor); Verhey, Timothy R. R. (Inventor); Soulas, George C. (Inventor)

    2001-01-01

    The present invention is a process for cleaning a cathode tube and other subassemblies in a hollow cathode assembly. In the disclosed process, hand covering elastomer gloves are used for handling all cathode assembly parts. The cathode tube and other subassemblies are cleaned with a lint-free cloth damped with acetone, then wiped with alcohol, immersed in ethyl alcohol or acetone, and ultrasonic agitation is applied, heating to 60 C. for ethyl alcohol or 56 C. for acetone. The cathode tube and other subassemblies are dried by blowing with nitrogen gas.

  20. Clean Air Slots Amid Dense Atmospheric Pollution in Southern Africa

    NASA Technical Reports Server (NTRS)

    Hobbs, Peter V.

    2003-01-01

    During the flights of the University of Washington's Convair-580 in the Southern African Regional Science Initiative (SAFARI 2000) in southern Africa, a phenomenon was observed that has not been reported previously. This was the occurrence of thin layers of remarkably clean air, sandwiched between heavily polluted air, which persisted for many hours during the day. Photographs are shown of these clean air slots (CAS), and particle concentrations and light scattering coefficients in and around such slot are presented. An explanation is proposed for the propensity of CAS to form in southern Africa during the dry season.

  1. The Effect of Selected Cleaning Techniques on Berkshire Lee Marble: A Scientific Study at Philadelphia City Hall

    USGS Publications Warehouse

    Mossotti, Victor G.; Eldeeb, A. Raouf; Fries, Terry L.; Coombs, Mary Jane; Naude, Virginia N.; Soderberg, Lisa; Wheeler, George S.

    2002-01-01

    This report describes a scientific investigation of the effects of eight different cleaning techniques on the Berkshire Lee marble component of the facade of the East Center Pavilion at Philadelphia City Hall; the study was commissioned by the city of Philadelphia. The eight cleaning techniques evaluated in this study were power wash (proprietary gel detergent followed by water rinse under pressure), misting (treatment with potable, nebulized water for 24-36 hours), gommage (proprietary Thomann-Hanry low-pressure, air-driven, small-particle, dry abrasion), combination (gommage followed by misting), Armax (sodium bicarbonate delivered under pressure in a water wash), JOS (dolomite powder delivered in a low-pressure, rotary-vortex water wash), laser (thermal ablation), and dry ice (powdered-dry-ice abrasion delivered under pressure). In our study approximately 160 cores were removed from the building for laboratory analysis. We developed a computer program to analyze scanning-electron-micrograph images for the microscale surface roughness and other morphologic parameters of the stone surface, including the near-surface fracture density of the stone. An analysis of more than 1,100 samples cut from the cores provided a statistical basis for crafting the essential elements of a reduced-form, mixed-kinetics conceptual model that represents the deterioration of calcareous stone in terms of self-organized soiling and erosion patterns. This model, in turn, provided a basis for identifying the variables that are affected by the cleaning techniques and for evaluating the extent to which such variables influence the stability of the stone. The model recognizes three classes of variables that may influence the soiling load on the stone, including such exogenous environmental variables as airborne moisture, pollutant concentrations, and local aerodynamics, and such endogenous stone variables as surface chemistry and microstructure (fracturing, roughness, and so on). This study showed that morphologic variables on the mesoscale to macroscale are not generally affected by the choice of a cleaning technique. The long-term soiling pattern on the building is independent of the cleaning technique applied. This study also showed that soluble salts do not play a significant role in the deterioration of Berkshire Lee marble. Although salts were evident in cracks and fissures of the heavily soiled stone, such salts did not penetrate the surface to a depth of more than a few hundred micrometers. The criteria used to differentiate the cleaning techniques were ultimately based on the ability of each technique to remove soiling without altering the texture of the stone surface. This study identified both the gommage and JOS techniques as appropriate for cleaning ashlar surfaces and the combination technique as appropriate for cleaning highly carved surfaces at the entablatures, cornices, and column capitals.

  2. Onycholysis

    MedlinePlus

    ... reaction to "poison Ivy") to nail hardener or adhesives used to attach the nail tips, or simply ... avoid mechanical cleaning under nails. One should not bandage or cover the cut nails. A drying agent ...

  3. Field-to-Fuel Performance Testing of Lignocellulosic Feedstocks: An Integrated Study of the Fast Pyrolysis/Hydrotreating Pathway

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Howe, Daniel T.; Westover, Tyler; Carpenter, Daniel

    2015-05-21

    Feedstock composition can affect final fuel yields and quality for the fast pyrolysis and hydrotreatment upgrading pathway. However, previous studies have focused on individual unit operations rather than the integrated system. In this study, a suite of six pure lignocellulosic feedstocks (clean pine, whole pine, tulip poplar, hybrid poplar, switchgrass, and corn stover) and two blends (equal weight percentages whole pine/tulip poplar/switchgrass and whole pine/clean pine/hybrid poplar) were prepared and characterized at Idaho National Laboratory. These blends then underwent fast pyrolysis at the National Renewable Energy Laboratory and hydrotreatment at Pacific Northwest National Laboratory. Although some feedstocks showed a highmore » fast pyrolysis bio-oil yield such as tulip poplar at 57%, high yields in the hydrotreater were not always observed. Results showed overall fuel yields of 15% (switchgrass), 18% (corn stover), 23% (tulip poplar, Blend 1, Blend 2), 24% (whole pine, hybrid poplar) and 27% (clean pine). Simulated distillation of the upgraded oils indicated that the gasoline fraction varied from 39% (clean pine) to 51% (corn stover), while the diesel fraction ranged from 40% (corn stover) to 46% (tulip poplar). Little variation was seen in the jet fuel fraction at 11 to 12%. Hydrogen consumption during hydrotreating, a major factor in the economic feasibility of the integrated process, ranged from 0.051 g/g dry feed (tulip poplar) to 0.070 g/g dry feed (clean pine).« less

  4. Dry efficient cleaning of poly-methyl-methacrylate residues from graphene with high-density H{sub 2} and H{sub 2}-N{sub 2} plasmas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cunge, G., E-mail: gilles.cunge@cea.fr; Petit-Etienne, C.; Davydova, A.

    Graphene is the first engineering electronic material, which is purely two-dimensional: it consists of two exposed sp{sup 2}-hybridized carbon surfaces and has no bulk. Therefore, surface effects such as contamination by adsorbed polymer residues have a critical influence on its electrical properties and can drastically hamper its widespread use in devices fabrication. These contaminants, originating from mandatory technological processes of graphene synthesis and transfer, also impact fundamental studies of the electronic and structural properties at the atomic scale. Therefore, graphene-based technology and research requires “soft” and selective surface cleaning techniques dedicated to limit or to suppress this surface contamination. Here,more » we show that a high-density H{sub 2} and H{sub 2}-N{sub 2} plasmas can be used to selectively remove polymeric residues from monolayer graphene without any damage on the graphene surface. The efficiency of this dry-cleaning process is evidenced unambiguously by a set of spectroscopic and microscopic methods, providing unprecedented insights on the cleaning mechanisms and highlighting the role of specific poly-methyl-methacrylate residues at the graphene interface. The plasma is shown to perform much better cleaning than solvents and has the advantage to be an industrially mature technology adapted to large area substrates. The process is transferable to other kinds of two-dimensional material and heterostructures.« less

  5. A qualitative evaluation of hand drying practices among Kenyans.

    PubMed

    Person, Bobbie; Schilling, Katharine; Owuor, Mercy; Ogange, Lorraine; Quick, Rob

    2013-01-01

    Recommended disease prevention behaviors of hand washing, hygienic hand drying, and covering one's mouth and nose in a hygienic manner when coughing and sneezing appear to be simple behaviors but continue to be a challenge to successfully promote and sustain worldwide. We conducted a qualitative inquiry to better understand current hand drying behaviors associated with activities of daily living, and mouth and nose covering practices, among Kenyans. We conducted 7 focus group discussions; 30 in-depth interviews; 10 structured household observations; and 75 structured observations in public venues in the urban area of Kisumu; rural communities surrounding Kisumu; and a peri-urban area outside Nairobi, Kenya. Using a grounded theory approach, we transcribed and coded the narrative data followed by thematic analysis of the emergent themes. Hand drying, specifically on a clean towel, was not a common practice among our participants. Most women dried their hands on their waist cloth, called a leso, or their clothes whether they were cooking, eating or cleaning the nose of a young child. If men dried their hands, they used their trousers or a handkerchief. Children rarely dried their hands; they usually just wiped them on their clothes, shook them, or left them wet as they continued with their activities. Many people sneezed into their hands and wiped them on their clothes. Men and women used a handkerchief fairly often when they had a runny nose, cold, or the flu. Most people coughed into the air or their hand. Drying hands on dirty clothes, rags and lesos can compromise the benefits of handwashing. Coughing and sneezing in to an open hand can contribute to spread of disease as well. Understanding these practices can inform health promotion activities and campaigns for the prevention and control of diarrheal disease and influenza.

  6. 29 CFR 780.151 - Particular operations on commodities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... AGRICULTURE, PROCESSING OF AGRICULTURAL COMMODITIES, AND RELATED SUBJECTS UNDER THE FAIR LABOR STANDARDS ACT... 3(f): (a) Grain, seed, and forage crops. Weighing, binning, stacking, drying, cleaning, grading...

  7. 29 CFR 780.151 - Particular operations on commodities.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... AGRICULTURE, PROCESSING OF AGRICULTURAL COMMODITIES, AND RELATED SUBJECTS UNDER THE FAIR LABOR STANDARDS ACT... 3(f): (a) Grain, seed, and forage crops. Weighing, binning, stacking, drying, cleaning, grading...

  8. 29 CFR 780.151 - Particular operations on commodities.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... AGRICULTURE, PROCESSING OF AGRICULTURAL COMMODITIES, AND RELATED SUBJECTS UNDER THE FAIR LABOR STANDARDS ACT... 3(f): (a) Grain, seed, and forage crops. Weighing, binning, stacking, drying, cleaning, grading...

  9. 29 CFR 780.151 - Particular operations on commodities.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... AGRICULTURE, PROCESSING OF AGRICULTURAL COMMODITIES, AND RELATED SUBJECTS UNDER THE FAIR LABOR STANDARDS ACT... 3(f): (a) Grain, seed, and forage crops. Weighing, binning, stacking, drying, cleaning, grading...

  10. 29 CFR 780.151 - Particular operations on commodities.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... AGRICULTURE, PROCESSING OF AGRICULTURAL COMMODITIES, AND RELATED SUBJECTS UNDER THE FAIR LABOR STANDARDS ACT... 3(f): (a) Grain, seed, and forage crops. Weighing, binning, stacking, drying, cleaning, grading...

  11. Ruptured eardrum

    MedlinePlus

    ... as from a powerful slap or explosion) Inserting cotton-tipped swabs or small objects into the ears ... clean and dry while it is healing. Place cotton balls in the ear while showering or shampooing ...

  12. Meatal stenosis

    MedlinePlus

    ... clean and dry. Avoid exposing the newly circumcised penis to any irritants. They may cause inflammation and ... Meatal stenosis References Elder JS. Anomalies of the penis and urethra. In: Kliegman RM, Stanton BF, St. ...

  13. Precision Cleaning of Oxygen Systems and Components

    NASA Technical Reports Server (NTRS)

    McLaughlin, Russell

    2009-01-01

    Currently, NASA uses Dichloropentafluoropropane (HCFC-225), a Class II ozone depleting substance (ODs), to clean contaminated oxygen systems. Starting in 20 15, the Montreal Protocols and Clean Air Act prohibit the production and importation of all hydrochlorofluorocarbons (HCFC), except for limited use in refrigeration applications. Thus, a new non-ozone depleting solvent needs to be developed for use in cleaning. Optimally, such a solvent should also be environmentally benign or green to avoid needing to replace the new solvent with yet another solvent in the future due to other environmental concerns. Work for the first year consisted of two parts. The first part was developing a method of testing the cleaning efficiency of potential solvents. Stainless steel coupons were contaminated with a known weight of various contaminants and contaminant combinations and then immersed in solvent for ten minutes. The coupons were then removed and dried in an oven until all solvent had evaporated. Once dry, the coupons were weighed and the mass of the non-volatile residue (NVR) left on the coupon was determined. The cleaning efficiency of the solvents is reported as percent cleaning, with 100% cleaning being zero NVR left on the test coupon. The second half of the first goal was to use the develop method to perform baseline testing on current solvents. The second part of the work was to begin exploring alternative cleaning solvents. A variety of hydrofluorocarbons (HFCs) were tested. Preliminary testing was also performed with ionic liquids and aqueous surfactant solutions. Once potential solvents were identified, an analysis of the performance and environmental characteristics of each was to be conducted. Four contaminants were specified for use in testing. These are Mil-Spec-H-5606 (5606), a hydraulic fluid, Mil-H-83282B (83282), another hydraulic fluid, diethylhexyl sebacate (Sebacate), and WD-40. The structures of these contaminants are all similar, with long aliphatic hydrocarbon chains of lengths between fifteen and fifty. Contaminants were tested both individually and in combination. All combinations were done with equal weights of the constituent contaminants.

  14. Pilot Plant Program for the AED Advanced Coal Cleaning System. Phase II. Interim final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1980-08-01

    Advanced Energy Dynamics, Inc. (AED), has developed a proprietary coal cleaning process which employs a combination of ionization and electrostatic separation to remove both sulfur and ash from dry pulverized coal. The Ohio Department of Energy sponsored the first part of a program to evaluate, develop, and demonstrate the process in a continuous-flow pilot plant. Various coals used by Ohio electric utilities were characterized and classified, and sulfur reduction, ash reduction and Btu recovery were measured. Sulfur removal in various coals ranged from 33 to 68% (on a Btu basis). Ash removal ranged from 17 to 59% (on a Btumore » basis). Ash removal of particles greater than 53 microns ranged from 46 to 88%. Btu recovery ranged from 90 to 97%. These results, especially the large percentage removal of ash particles greater than 53 microns, suggest that the AED system can contribute materially to improved boiler performance and availability. The study indicated the following potential areas for commercial utilization of the AED process: installation between the pulverizer and boiler of conventional coal-fired power utilities; reclamation of fine coal refuse; dry coal cleaning to supplement, and, if necessary, to take the place of conventional coal cleaning; upgrading coal used in: (1) coal-oil mixtures, (2) gasification and liquefaction processes designed to handle pulverized coal; and (3) blast furnaces for making steel, as a fuel supplement to the coke. Partial cleaning of coking coal blends during preheating may also prove economically attractive. Numerous other industrial processes which use pulverized coal such as the production of activated carbon and direct reduction of iron ore may also benefit from the use of AED coal cleaning.« less

  15. Dynamic self-cleaning in gecko setae via digital hyperextension

    PubMed Central

    Hu, Shihao; Lopez, Stephanie; Niewiarowski, Peter H.; Xia, Zhenhai

    2012-01-01

    Gecko toe pads show strong adhesion on various surfaces yet remain remarkably clean around everyday contaminants. An understanding of how geckos clean their toe pads while being in motion is essential for the elucidation of animal behaviours as well as the design of biomimetic devices with optimal performance. Here, we test the self-cleaning of geckos during locomotion. We provide, to our knowledge, the first evidence that geckos clean their feet through a unique dynamic self-cleaning mechanism via digital hyperextension. When walking naturally with hyperextension, geckos shed dirt from their toes twice as fast as they would if walking without hyperextension, returning their feet to nearly 80 per cent of their original stickiness in only four steps. Our dynamic model predicts that when setae suddenly release from the attached substrate, they generate enough inertial force to dislodge dirt particles from the attached spatulae. The predicted cleaning force on dirt particles significantly increases when the dynamic effect is included. The extraordinary design of gecko toe pads perfectly combines dynamic self-cleaning with repeated attachment/detachment, making gecko feet sticky yet clean. This work thus provides a new mechanism to be considered for biomimetic design of highly reuseable and reliable dry adhesives and devices. PMID:22696482

  16. 9 CFR 147.22 - Hatching egg sanitation.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... AGRICULTURE LIVESTOCK IMPROVEMENT AUXILIARY PROVISIONS ON NATIONAL POULTRY IMPROVEMENT PLAN Sanitation... soiled nest eggs may be gently dry cleaned by hand. (c) Hatching eggs should be stored in a designated...

  17. The Effectiveness of the Removal of DNA from the Surfaces of EVA-Based Mouthguards using Standard Cleaning Protocols

    DTIC Science & Technology

    2016-06-16

    Dental Association has recognized the value of mouthguards for all those who participate in contact sports and recreational activities in the...sustaining dental injuries in sporting activities , including organized and unorganized sports at both recreational and competitive levels.3 Since mouthguards...Overall p-value=0.008 based on logged analysis. Air dry and Commercial mouthguard cleaning tablet performed better than the antibacterial hand soap (p

  18. Electrodeposition Painting of Metal Substrates: Pinholing in Surface Films,

    DTIC Science & Technology

    1978-08-01

    a bright surface and rubbed clean with a moist cloth to remove the fine dust of metal adhering to the surface, dried, degrea.ed and desmutted by...rubbing with mineral turpentine . This procedure conforms to Australian Standards AS 1580 (May 1975), ‘Pretreatment of Metal Test Panels’. 2.3...deposition, the panels were carefully washed with clean water to remove loosely adhering excess paint which resulted solely from contact of the panel with

  19. Optimum storage and germination conditions for seeds of pickerelweed (Pontetieria cordata L.) from Florida

    Treesearch

    Lyn A. Gettys; R. Kasten Dumroese

    2009-01-01

    Clean seeds of pickerelweed (Pontederia cordata L. [Pontederiaceae]) germinated best (84 to 94%) under water, even after being stored dry up to 6 mo at about 25 °C (77 °F), but germination of clean seeds under water was reduced to 43% when seeds were stored at 4 °C (39 3 F) for 6 mo. Underwater germination of seeds enclosed in fruits was less...

  20. Groundwater Flow Through a Constructed Treatment Wetland

    DTIC Science & Technology

    2003-03-01

    the treatment wetland is to biodegrade perchloroethylene, which is present in the groundwater as a contaminant. Contaminated water enters the...characterizing groundwater flow through a constructed treatment wetland, one can visualize the flow paths of water through various types of soil. With...flowing groundwater and are now appearing in drinking water wells. Since contamination originated from government practices at many of these sites

  1. Phytoremediation of Trichloroethylene and Perchloroethylene at the Savannah River Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brigmon, R.L.

    Bioremediation of chlorinated solvents, both natural and accelerated, is exemplified by phytoremediation and biodegradation by rhizosphere microorganisms. Phytoremediation is the use of vegetation for the treatment of contaminated soils, sediments, and water. The potential for phytoremediation of chlorinated solvents has been demonstrated at the Savannah River Site (SRS) Miscellaneous Chemical Basin, Southern Sector of A/M Area and TNX/D-Area. Recent characterization work at the SRS has delineated widespread plumes (1-2 miles) of low concentration (40 ppb -10-ppm range) trichloroethylene (TCE) and perchloroethylene (PCE) contaminated groundwater. Phytoremediation deployments are underway for TCE and PCE phytoremediation in select SRS areas. Phytoremediation appears tomore » be an excellent technology to intercept and control plume migration. The ongoing Southern Sector treatability study is part of a multi-year field study of SRS seepline-soil systems maintained under saturated conditions. The primary focus is on determining how trees, seepline groundcover, soil microbial communities, and geochemical and surface-volatilization processes affect TCE and PCE in contaminated groundwater that flows through surface seepline areas. Therefore, FY00 represented an initial acclimation phase for soil and plant systems and will facilitate examination of seepline phyto- and bioactivity in subsequent growth season in FY01.« less

  2. Design and Development of Mopping Robot-'HotBot'

    NASA Astrophysics Data System (ADS)

    Khan, M. R.; Huq, N. M. L.; Billah, M. M.; Ahmmad, S. M.

    2013-12-01

    To have a healthy, comfortable, and fresh civilized life we need to do some unhealthy households. Cleaning the dirty floor with a mop is one of the most disgusting and scary house hold jobs. Mopping robots are a solution of such problem. However, these robots are still on the way to be smart enough. Many points limit their efficiency, i.e. cleaning sticky dirt, having dry floor after cleaning, monitoring, cost etc. 'HotBot' is a mopping robot that can clean dirty floor with nice efficiency leaving no sticky dirt. Hot water can be used for heavy stains or normal water for usual situation and economy. It needs neither to be monitored during mopping nor to wipe the floor after it. 'HotBot' has sensors to detect obstacles and a control mechanism to avoid those. Moreover, it cleans sequentially and equipped with several accident-protection-systems. Moreover, it is also cost effective compared to the robots available so far.

  3. How-to-Do-It: Diatoms: The Ignored Alga in High School Biology.

    ERIC Educational Resources Information Center

    Hungerford, James J.

    1988-01-01

    Provides historical background, descriptions, uses and basis for identification of diatoms. Explains collection, dry-mount cleaning, and preparation procedures of the algae. Cites additional resources. (RT)

  4. 40 CFR 435.41 - Specialized definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., safety showers, eye-wash stations, hand-wash stations, fish cleaning stations, and galleys located within... formation oil carried out from the wellbore with the drilling fluid. (2) Dry drill cuttings means the...

  5. Irritants and allergens at school in relation to furnishings and cleaning.

    PubMed

    Smedje, G; Norbäck, D

    2001-06-01

    In order to study the influence of furnishings and cleaning on the indoor air quality at school, 181 randomly chosen classrooms were investigated. The amounts of open shelves, textiles and other fittings were noted, data were gathered on cleaning routines, and a number of pollutants were measured in the classrooms. In classrooms with more fabrics there was more settled dust and the concentration of formaldehyde was higher. Classrooms with more open shelves had more formaldehyde, and more pet allergens in settled dust, and classrooms with a white board, instead of a chalk board, were less dusty. Classrooms mainly cleaned through wet mopping had more airborne viable bacteria but less settled dust than classrooms mainly cleaned by dry methods. In rooms where the desks and curtains were more often cleaned, the concentrations of cat and dog allergen in settled dust were lower. It is concluded that furnishings and textiles in the classroom act as significant reservoirs of irritants and allergens and have an impact on the indoor air quality at school.

  6. Immunological monitoring of dry-cleaning shop workers--exposure to tetrachloroethylene.

    PubMed

    Andrýs, C; Hanovcová, I; Chýlková, V; Tejral, J; Eminger, S; Procházková, J

    1997-09-01

    A panel of immunological parameters has been examined in a group of dry-cleaning workers (n = 21) and in a control group of administrators (n = 16) from the same plant. The results were also compared to long-term laboratory reference values (LRV) (n = 14-311). External exposure to tetrachloroethylene (PER) was represented by TWA (8 h) values in the range 11-752 mg PER/m3. Biological monitoring showed an amount from 9 to 344 mg PER/m3 in exhaled air by the end of workshift. 1. The exposed dry-cleaning workers compared to the controls from the plant had statistically significant changes in metabolic activity of phagocytes, alpha 2-macroglobulin, C3 and C4 complement component, salivary secretory IgA, and blastic transformation test. Most of the values were within the range of normal values. 2. The exposed dry-cleaning workers had several abnormal immune parameters compared to the long-term laboratory values (LRV) especially in the alpha 2-macroglobulin, C3 and percentage of T-lymphocytes. Most of the changes, even those that were statistically significant, were still within the range of normal values, but they might be classified as trends or shifts away from normal (spontaneous blastic transformation, absolute number of phagocyting cells, coeruloplasmin, circulating immunocomplexes, serum lysozyme). 3. The non-exposed controls from the same plant showed both quantitative and qualitative differences when compared to the LRV. Changes were seen in IgG, C4, CSI and in increased spontaneous metabolic activity of leucocytes, total leucocyte count, absolute number of phagocyting cells, alpha 2-macroglobulin, prealbumin, C4, circulating immunocomplexes and serum lysozyme. 4. The distribution analysis of all results detected a large number of abnormal values in both groups, more in the at-risk group. 5. As inhalation was the main route of PER exposure it was concluded that the changes might represent aspects of the response of the respiratory immune system, mainly of the alveolar macrophages. Additional postinfection effects could not be excluded in both studied groups. Individual differences in immune reactivity as well as individual range of exposure should be taken into consideration.

  7. Seasonal variations and shared latrine cleaning practices in the slums of Kampala city, Uganda.

    PubMed

    Kwiringira, Japheth; Atekyereza, Peter; Niwagaba, Charles; Kabumbuli, Robert; Rwabukwali, Charles; Kulabako, Robinah; Günther, Isabel

    2016-04-27

    The effect of seasons on health outcomes is a reflection on the status of public health and the state of development in a given society. Evidence shows that in Sub-Saharan Africa, most infectious diseases flourish during the wet months of the year; while human activities in a context of constrained choices in life exacerbate the effects of seasons on human health. The paper argues that, the wet season and when human activities are at their peak, sanitation is most dire poor slum populations. A shared latrine cleaning observation was undertaken over a period of 6 months in the slums of Kampala city. Data was collected through facility observations, user group meetings, Focus group discussions and, key informant interviews. The photos of the observed sanitation facilities were taken and assessed for facility cleanliness or dirt. Shared latrine pictures, observations, Focus Group Discussion, community meetings and key informant interviews were analysed and subjected to an analysis over the wet, dry and human activity cycles before a facility was categorised as either 'dirty' or 'clean'. Human activity cycles also referred to as socio-economic seasons were, school days, holidays, weekends and market days. These have been called 'impure' seasons, while the 'pure' seasons were the wet and dry months: improved and unimproved facilities were negatively affected by the wet seasons and the peak seasons of human activity. Wet seasons were associated with, mud and stagnant water, flooding pits and a repugnant smell from the latrine cubicle which made cleaning difficult. During the dry season, latrines became relatively cleaner than during the wet season. The presence of many child(ren) users during school days as well as the influx of market goers for the roadside weekly markets compromised the cleaning outcomes for these shared sanitation facilities. Shared latrine cleaning in slums is impacted by seasonal variations related to weather conditions and human activity. The wet seasons made the already bad sanitation situation worse. The seasonal fluctuations in the state of shared slum sanitation relate to a wider malaise in the population and an implied capacity deficit among urban authorities. Poor sanitation in slums is part of a broader urban mismanagement conundrum pointing towards the urgent need for multiple interventions aimed at improving the general urban living conditions well beyond sanitation.

  8. DNA decontamination of fingerprint brushes.

    PubMed

    Szkuta, Bianca; Oorschot, Roland A H van; Ballantyne, Kaye N

    2017-08-01

    Genetic profiling of DNA collected from fingerprints that have been exposed to various enhancement techniques is routine in many forensic laboratories. As a result of direct contact with fingermark residues during treatment, there is concern around the DNA contamination risk of dusting fingermarks with fingerprint brushes. Previous studies have demonstrated the potential for cross-contamination between evidentiary items through various mechanisms, highlighting the risk of using the same fingerprint brush to powder multiple surfaces within and between crime-scenes. Experiments were performed to assess the contamination risk of reused fingerprint brushes through the transfer of dried saliva and skin deposits from and to glass surfaces with new unused squirrel hair and fiberglass brushes. Additional new unused brushes and brushes previously used in casework were also tested for their ability to contaminate samples. In addition, the ability to eradicate DNA from used squirrel hair and fiberglass fingerprint brushes was assessed using a 1% sodium hypochlorite solution and a 5% solution of a commercially available alternative, Virkon. DNA profiling results from surfaces contacted by treated and untreated brushes were compared to determine the effectiveness of the devised cleaning protocol. Brush durability was also assessed over multiple wash/rinse/dry cycles with both agents. Varying amounts of DNA-containing material were collected and transferred by squirrel hair and fiberglass brushes, with detectability on the secondary surface dependent on the biological nature of the material being transferred. The impact of DNA contamination from dirty fingerprint brushes was most apparent in simulations involving the transfer of dried saliva and brushes previously used in casework, while minimal transfer of touch DNA was observed. Alarmingly, large quantities of DNA were found to reside on new unused squirrel hair brushes, while no DNA was detected on new unused fiberglass brushes or brushes sold as DNA-free. Squirrel hair brushes were easily and effectively cleaned with both hypochlorite and Virkon, with no evidence of DNA transfer between exhibits by treated brushes. Brushes were still deemed useable after multiple cleaning cycles with either agent. In contrast, fiberglass bristles became tangled and matted when wet and could not be cleaned effectively using either method. It is recommended they are disposed of following use. Each laboratory should consider their current circumstances before adapting a cleaning method. The implementation of a program to monitor the effectiveness of the cleaning regime is also advised. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Pilot-Scale Demonstration of In-Situ Chemical Oxidation ...

    EPA Pesticide Factsheets

    A pilot-scale in situ chemical oxidation (ISCO) demonstration, involving subsurface injections of sodium permanganate (NaMnO4), was performed at the US Marine Corp Recruit Depot (MCRD), site 45 (Parris Island (PI), SC). The ground water was originally contaminated with perchloroethylene (PCE) (also known as tetrachloroethylene), a chlorinated solvent used in dry cleaner operations. High resolution site characterization involved multiple iterations of soil core sampling and analysis. Nested micro-wells and conventional wells were also used to sample and analyze ground water for PCE and decomposition products (i.e., trichloroethyelene (TCE), dichloroethylene (c-DCE, t-DCE), and vinyl chloride (VC)), collectively referred to as chlorinated volatile organic compounds (CVOC). This characterization methodology was used to develop and refine the conceptual site model and the ISCO design, not only by identifying CVOC contamination but also by eliminating uncontaminated portions of the aquifer from further ISCO consideration. Direct-push injection was selected as the main method of NaMnO4 delivery due to its flexibility and low initial capital cost. Site impediments to ISCO activities in the source area involved subsurface utilities, including a high pressure water main, a high voltage power line, a communication line, and sanitary and stormwater sewer lines. Utility markings were used in conjunction with careful planning and judicious selection of injection locations. A

  10. Investigations on laser hard tissue ablation under various environments

    NASA Astrophysics Data System (ADS)

    Kang, H. W.; Oh, J.; Welch, A. J.

    2008-06-01

    The purpose of this study was to investigate the effect of liquid environments upon laser bone ablation. A long-pulsed Er,Cr:YSGG laser was employed to ablate bovine bone tibia at various radiant exposures under dry, wet (using water or perfluorocarbon) and spray environmental conditions. Energy loss by the application of liquid during laser irradiation was evaluated, and ablation performance for all conditions was quantitatively measured by optical coherence tomography (OCT). Microscope images were also used to estimate thermal side effects in tissue after multiple-pulse ablation. Wet using water and spray conditions equally attenuated the 2.79 µm wavelength laser beam. Higher transmission efficiency was obtained utilizing a layer of perfluorocarbon. Dry ablation exhibited severe carbonization due to excessive heat accumulation. Wet condition using water resulted in similar ablation volume to the dry case without carbonization. The perfluorocarbon layer produced the largest ablation volume but some carbonization due to the poor thermal conductivity. Spray induced clean cutting with slightly reduced efficiency. Liquid-assisted ablation provided significant beneficial effects such as augmented material removal and cooling/cleaning effects during laser osteotomy.

  11. Hazardous waste management and weight-based indicators--the case of Haifa Metropolis.

    PubMed

    Elimelech, E; Ayalon, O; Flicstein, B

    2011-01-30

    The quantity control of hazardous waste in Israel relies primarily on the Environmental Services Company (ESC) reports. With limited management tools, the Ministry of Environmental Protection (MoEP) has no applicable methodology to confirm or monitor the actual amounts of hazardous waste produced by various industrial sectors. The main goal of this research was to develop a method for estimating the amounts of hazardous waste produced by various sectors. In order to achieve this goal, sector-specific indicators were tested on three hazardous waste producing sectors in the Haifa Metropolis: petroleum refineries, dry cleaners, and public hospitals. The findings reveal poor practice of hazardous waste management in the dry cleaning sector and in the public hospitals sector. Large discrepancies were found in the dry cleaning sector, between the quantities of hazardous waste reported and the corresponding indicator estimates. Furthermore, a lack of documentation on hospitals' pharmaceutical and chemical waste production volume was observed. Only in the case of petroleum refineries, the reported amount was consistent with the estimate. Copyright © 2010 Elsevier B.V. All rights reserved.

  12. 2008 Homeland Security S and T Stakeholders Conference West volume 2 Monday

    DTIC Science & Technology

    2008-01-16

    per collection and pressure to be applied, etc. . - Enviromental effects; dry vs. wet surface (vs. type of sample swipe), clean vs. dirty surfaces...selection of collection via low volume or high volume sampling, distance to suspect item critical, etc. - Enviromental effects; temperature (range of...selection of material, collection via hand wiping or sampling wand, area per collection and pressure to be applied, etc. . - Enviromental effects; dry

  13. AGOR 28

    DTIC Science & Technology

    2015-11-20

    unclassified c. THIS PAGE unclassified Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 2 Exhaust Baffles • December Dry ...Docking Canceled – The floating dry dock is not certified so the docking has been canceled. Divers should do hull and prop cleaning prior to builders...operating temperature of 125-degrees F. A cooler may be necessary to correct this issue. • Uncontaminated Sea Chest – Reports from Armstrong indicate

  14. Ricketts Community Update No 3

    EPA Pesticide Factsheets

    In February 2017, the U.S. Environmental Protection Agency (EPA) collected air samples at 50 properties located near the Rickett’s Dry Cleaning facility located at 2017 Doubleday Avenue in the village of Ballston Spa.

  15. Poet North Manchester Approval

    EPA Pesticide Factsheets

    This update August 9, 2016 letter from EPA approves, with modifications, the petition from Poet Biorefining-North Manchester, LLC, regarding non-grandfathered ethanol produced through a dry mill process, qualifying under the Clean Air Act for renewable

  16. Poet Marion Approval

    EPA Pesticide Factsheets

    This update August 9, 2016 letter from EPA approves, with modifications, the petition from Poet Biorefining-North Manchester, LLC, regarding non-grandfathered ethanol produced through a dry mill process, qualifying under the Clean Air Act for renewable

  17. Poet Portland Approval

    EPA Pesticide Factsheets

    This update August 9, 2016 letter from EPA approves the petition, with modifications, from Poet Biorefining-Portland, LLC, regarding non-grandfathered ethanol produced through a dry mill process, qualifying under the Clean Air Act for renewable fuel

  18. Poet Laddonia Approval

    EPA Pesticide Factsheets

    This update Auugust 9, 2016 letter from EPA approves with modifications, the petition from Poet Biorefining Laddonia, Poet Laddonia Facility, regarding non-grandfathered ethanol produced through a dry mill process, qualifying under the Clean Air Act f

  19. Poet Alexandria Approval

    EPA Pesticide Factsheets

    This update August 9, 2016 letter from EPA approves, with modifications, the petition from Poet Biorefining-Alexandria, LLC, regarding non-grandfathered ethanol produced through a dry mill process, qualifying under the Clean Air Act for renewable fuel

  20. 40 CFR 60.622 - Standards for volatile organic compounds.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., and maintained. (b) Each affected petroleum solvent filter that is installed at a petroleum dry cleaning plant after December 14, 1982, shall be a cartridge filter. Cartridge filters shall be drained in...

  1. 40 CFR 60.622 - Standards for volatile organic compounds.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., and maintained. (b) Each affected petroleum solvent filter that is installed at a petroleum dry cleaning plant after December 14, 1982, shall be a cartridge filter. Cartridge filters shall be drained in...

  2. Electrodialytic remediation of municipal solid waste incineration residues using different membranes.

    PubMed

    Parés Viader, Raimon; Jensen, Pernille Erland; Ottosen, Lisbeth M

    2017-02-01

    In the present work, three different commercial membrane brands were used in an identical electrodialytic cell setup and operating conditions, in order to reduce the leaching of metals and salt anions of two types of municipal solid waste incineration residues: air pollution control residues of a semi-dry flue-gas cleaning system and fly ashes from a plant with wet flue-gas cleaning system. The results showed a general reduction of the leaching in both residues after ED remediation. For the following elements, the leaching was found to be different after ED treatment depending on the membrane used, with statistical significance: • Air pollution control residues of the semi-dry flue-gas cleaning system: Cr, Cu, Ni, Pb, Zn; • Fly ashes from a plant with wet flue-gas cleaning system: Al, Ba, Cu, Ni, Zn, Cl, SO 4 . Final leaching values for some elements and membranes, but not the majority, were below than those of certified coal fly ash (e.g. Al or Cr), a material which is commonly used in construction materials; at the same time, some of these values were reduced to below the Danish law thresholds on the use of contaminated soil in constructions. These results show the potential of ED as a technology to upgrade municipal solid waste incineration residues. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Degradation of halogenated aliphatic compounds by the ammonia- oxidizing bacterium Nitrosomonas europaea.

    PubMed

    Vannelli, T; Logan, M; Arciero, D M; Hooper, A B

    1990-04-01

    Suspensions of Nitrosomonas europaea catalyzed the ammonia-stimulated aerobic transformation of the halogenated aliphatic compounds dichloromethane, dibromomethane, trichloromethane (chloroform), bromoethane, 1,2-dibromoethane (ethylene dibromide), 1,1,2-trichloroethane, 1,1,1-trichloroethane, monochloroethylene (vinyl chloride), gem-dichloroethylene, cis- and trans-dichloroethylene, cis-dibromoethylene, trichloroethylene, and 1,2,3-trichloropropane, Tetrachloromethane (carbon tetrachloride), tetrachloroethylene (perchloroethylene), and trans-dibromoethylene were not degraded.

  4. Manual versus automated methods for cleaning reusable accessory devices used for minimally invasive surgical procedures.

    PubMed

    Alfa, M J; Nemes, R

    2004-09-01

    We undertook a simulated-use study using quantitative methods to evaluate the cleaning efficacy of ported and non-ported accessory devices used in minimally invasive surgery. We chose laparoscopic scissors and forceps to represent worst-case devices which were inoculated with artificial test soil containing 10(6) cfu/mL Enterococcus faecalis and Geobacillus stearothermophilus and allowed to dry for 1 h. Cleaning was performed manually, as well as by the automated SI-Auto Narrow lumen cleaner. Manual cleaning left two- to 50-fold more soil residuals (protein, haemoglobin and carbohydrate) inside the lumen of non-ported versus ported laparoscopic accessory devices. The SI-Auto Narrow lumen cleaner was more efficient than manual cleaning and achieved >99% reduction in soil parameters in both non-ported (using retro-flushing) and ported laparoscopic devices. Only the automated cleaning of ported devices achieved 10(3)-10(4)-fold reduction in bacterial numbers. Sonication alone (no flushing of inner channel) did not effectively remove soil or organisms from the inner channel. Our findings indicate that non-ported accessory devices cannot be as reliably cleaned as ported devices regardless of the cleaning method used. If non-ported accessory devices are reprocessed, they should be cleaned using retro-flushing in an automated narrow lumen cleaner.

  5. 49 CFR 572.102 - Drop test.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... that ensure instant release onto a rigidly supported flat horizontal steel plate, which is 2 inches thick and 2 feet square. The plate shall have a clean, dry surface and any microfinish of not less than...

  6. 29 CFR 1910.22 - General requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... performed. Measures for the control of toxic materials are considered to be outside the scope of this... maintained in a clean and, so far as possible, a dry condition. Where wet processes are used, drainage shall...

  7. Poet Fostoria Approval

    EPA Pesticide Factsheets

    This August 9, 2016 letter from EPA approves, with modifications, the petition from Poet Biorefining-Fostoria, LLC, regarding non-grandfathered ethanol produced through a dry mill process, qualifying under the Clean Air Act for renewable fuel (D-code 6)

  8. Poet Leipsic Approval

    EPA Pesticide Factsheets

    This August 9, 2016 letter from EPA approves,wtih modifications, the petition from Poet Biorefining-Leipsic, LLC, regarding non-grandfathered ethanol produced through a dry mill process, qualifying under the Clean Air Act for renewable fuel (D-code 6) RINs

  9. Kansas Ethanol Lyons Approval

    EPA Pesticide Factsheets

    This update August 9, 2016 letter from EPA approves, with modifications, the petition from Kansas Ethanol, LLC, Lyons facility, regarding non-grandfathered ethanol produced through a dry mill process, qualifying under the Clean Air Act for renewable fuel

  10. Injury Prevention

    MedlinePlus

    ... your child's chance of injury in the home: Use safety latches and locks on cabinets and drawers. Buy all medicines with childproof caps and always keep them closed. Keep lightweight plastic bags, such as dry cleaning bags, grocery bags, and ...

  11. 49 CFR 176.805 - On deck stowage.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... for leakage from any package to drain away from other cargo into an overboard scupper or freeing port... stowage is not practical, sufficient clean dry sand must be placed under and around the lower tier of...

  12. Environmental microbiology as related to planetary quarantine. [synergetic effect of heat and radiation

    NASA Technical Reports Server (NTRS)

    Pflug, I. J.

    1973-01-01

    The mechanistic basis of the synergetic effect of combined heat and radiation on microbial destruction was analyzed and results show that radiation intensity, temperature, and relative humidity are the determining factors. Dry heat resistance evaluation for selected bacterial spore crops indicates that different strains of Bacillus stearothermophilus demonstrate marked differences in resistance. Preliminary work to determine the effects of storage time, suspending medium, storage temperature and spore crop cleaning procedures on dry heat survival characteristics of Bacillus subtilis var. Niger, and dry heat resistance of natural microflora in soil particles is also reported.

  13. Biochemical Effects of Cadmium Exposure and the Potential Pharmacologic Significance of Cadmium Mediated Hydrolase Inhibition

    DTIC Science & Technology

    1997-04-18

    DNA polymerase Alcohol dehydrogenase Hexokinase Glucose-6- phosphatase Arginase Pyruvate kinase (also requires Mg2•) Urease Nitrate...cyclohexane. The layers are separated by centrifugation (5 min at 1000 x g), the top organic layer is removed and dried with anhydrous sodium sulfate...An aliquot of the dried organic layer is transferred to a clean tube and evaporated under a gentle stream of nitrogen at room temperature

  14. Delta-Doping at Wafer Level for High Throughput, High Yield Fabrication of Silicon Imaging Arrays

    NASA Technical Reports Server (NTRS)

    Hoenk, Michael E. (Inventor); Nikzad, Shoulch (Inventor); Jones, Todd J. (Inventor); Greer, Frank (Inventor); Carver, Alexander G. (Inventor)

    2014-01-01

    Systems and methods for producing high quantum efficiency silicon devices. A silicon MBE has a preparation chamber that provides for cleaning silicon surfaces using an oxygen plasma to remove impurities and a gaseous (dry) NH3 + NF3 room temperature oxide removal process that leaves the silicon surface hydrogen terminated. Silicon wafers up to 8 inches in diameter have devices that can be fabricated using the cleaning procedures and MBE processing, including delta doping.

  15. Clean Air Slots Amid Atmospheric Pollution

    NASA Technical Reports Server (NTRS)

    Hobbs, Peter V.

    2002-01-01

    Layering in the Earth's atmosphere is most commonly seen where parts of the atmosphere resist the incursion of air parcels from above and below - for example, when there is an increase in temperature with height over a particular altitude range. Pollutants tend to accumulate underneath the resulting stable layers. which is why visibility often increases markedly above certain altitudes. Here we describe the occurrence of an opposite effect, in which stable layers generate a layer of remarkably clean air (we refer to these layers as clean-air 'slots') sandwiched between layers of polluted air. We have observed clean-air slots in various locations around the world, but they are particularly well defined and prevalent in southern Africa during the dry season August-September). This is because at this time in this region, stable layers are common and pollution from biomass burning is widespread.

  16. A Qualitative Evaluation of Hand Drying Practices among Kenyans

    PubMed Central

    Person, Bobbie; Schilling, Katharine; Owuor, Mercy; Ogange, Lorraine; Quick, Rob

    2013-01-01

    Background Recommended disease prevention behaviors of hand washing, hygienic hand drying, and covering one’s mouth and nose in a hygienic manner when coughing and sneezing appear to be simple behaviors but continue to be a challenge to successfully promote and sustain worldwide. We conducted a qualitative inquiry to better understand current hand drying behaviors associated with activities of daily living, and mouth and nose covering practices, among Kenyans. Methods and Findings We conducted 7 focus group discussions; 30 in-depth interviews; 10 structured household observations; and 75 structured observations in public venues in the urban area of Kisumu; rural communities surrounding Kisumu; and a peri-urban area outside Nairobi, Kenya. Using a grounded theory approach, we transcribed and coded the narrative data followed by thematic analysis of the emergent themes. Hand drying, specifically on a clean towel, was not a common practice among our participants. Most women dried their hands on their waist cloth, called a leso, or their clothes whether they were cooking, eating or cleaning the nose of a young child. If men dried their hands, they used their trousers or a handkerchief. Children rarely dried their hands; they usually just wiped them on their clothes, shook them, or left them wet as they continued with their activities. Many people sneezed into their hands and wiped them on their clothes. Men and women used a handkerchief fairly often when they had a runny nose, cold, or the flu. Most people coughed into the air or their hand. Conclusions Drying hands on dirty clothes, rags and lesos can compromise the benefits of handwashing. Coughing and sneezing in to an open hand can contribute to spread of disease as well. Understanding these practices can inform health promotion activities and campaigns for the prevention and control of diarrheal disease and influenza. PMID:24069302

  17. 29 CFR 1910.264 - Laundry machinery and operations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... of operation of laundry machines. This section does not apply to dry-cleaning operations. (c) Point... against touching the eyes, mouth, or any part of the body on which the skin has been broken by a scratch...

  18. 29 CFR 1910.264 - Laundry machinery and operations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... of operation of laundry machines. This section does not apply to dry-cleaning operations. (c) Point... against touching the eyes, mouth, or any part of the body on which the skin has been broken by a scratch...

  19. 29 CFR 1910.264 - Laundry machinery and operations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... of operation of laundry machines. This section does not apply to dry-cleaning operations. (c) Point... against touching the eyes, mouth, or any part of the body on which the skin has been broken by a scratch...

  20. 29 CFR 1910.264 - Laundry machinery and operations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... of operation of laundry machines. This section does not apply to dry-cleaning operations. (c) Point... against touching the eyes, mouth, or any part of the body on which the skin has been broken by a scratch...

  1. 29 CFR 1910.264 - Laundry machinery and operations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... of operation of laundry machines. This section does not apply to dry-cleaning operations. (c) Point... against touching the eyes, mouth, or any part of the body on which the skin has been broken by a scratch...

  2. Didion Cambria Approval

    EPA Pesticide Factsheets

    This May 9, 2016 letter from EPA approves the petition from Didion Ethanol, LLC, regarding non-grandfathered ethanol produced through a dry mill process, qualifying under the Clean Air Act for renewable fuel (D-code 6) RINs under the RFS program.

  3. Poet Lake Crystal Approval

    EPA Pesticide Factsheets

    This September 19, 2016 letter from EPA approves the petition from Poet Biorefining-Lake Crystal, regarding non-grandfathered ethanol produced through a dry mill process, qualifying under the Clean Air Act for renewable fuel (D-code 6) RINs under the RFS

  4. Capillary-Driven Microfluidic Chips for Miniaturized Immunoassays: Efficient Fabrication and Sealing of Chips Using a "Chip-Olate" Process.

    PubMed

    Temiz, Yuksel; Delamarche, Emmanuel

    2017-01-01

    The fabrication of silicon-based microfluidic chips is invaluable in supporting the development of many microfluidic concepts for research in the life sciences and in vitro diagnostic applications such as the realization of miniaturized immunoassays using capillary-driven chips. While being extremely abundant, the literature covering microfluidic chip fabrication and assay development might not have addressed properly the challenge of fabricating microfluidic chips on a wafer level or the need for dicing wafers to release chips that need then to be further processed, cleaned, rinsed, and dried one by one. Here, we describe the "chip-olate" process wherein microfluidic structures are formed on a silicon wafer, followed by partial dicing, cleaning, and drying steps. Then, integration of reagents (if any) can be done, followed by lamination of a sealing cover. Breaking by hand the partially diced wafer yields individual chips ready for use.

  5. Relationships between socioeconomic and lifestyle factors and indoor air quality in French dwellings.

    PubMed

    Brown, Terry; Dassonville, Claire; Derbez, Mickael; Ramalho, Olivier; Kirchner, Severine; Crump, Derrick; Mandin, Corinne

    2015-07-01

    To date, few studies have analyzed the relationships between socioeconomic status (SES) and indoor air quality (IAQ). The aim of this study was to examine the relationships between socioeconomic and other factors and indoor air pollutant levels in French homes. The indoor air concentrations of thirty chemical, biological and physical parameters were measured over one week in a sample of 567 dwellings representative of the French housing stock between September 2003 and December 2005. Information on SES (household structure, educational attainment, income, and occupation), building characteristics, and occupants' habits and activities (smoking, cooking, cleaning, etc.) were collected through administered questionnaires. Separate stepwise linear regression models were fitted to log-transformed concentrations on SES and other factors. Logistic regression was performed on fungal contamination data. Households with lower income were more likely to have higher indoor concentrations of formaldehyde, but lower perchloroethylene indoor concentrations. Formaldehyde indoor concentrations were also associated with newly built buildings. Smoking was associated with increasing acetaldehyde and PM2.5 levels and the risk of a positive fungal contamination index. BTEX levels were also associated with occupant density and having an attached garage. The major predictors for fungal contamination were dampness and absolute humidity. These results, obtained from a large sample of dwellings, show for the first time in France the relationships between SES factors and indoor air pollutants, and believe they should be considered alongside occupant activities and building characteristics when study IAQ in homes. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.

  6. Genesis Spacecraft Science Canister Preliminary Inspection and Cleaning

    NASA Technical Reports Server (NTRS)

    Hittle, J. D.; Calaway, M. J.; Allton, J. H.; Warren, J. L.; Schwartz, C. M.; Stansbery, E. K.

    2006-01-01

    The Genesis science canister is an aluminum cylinder (75 cm diameter and 35 cm tall) hinged at the mid-line for opening. This canister was cleaned and assembled in an ISO level 4 (Class 10) clean room at Johnson Space Center (JSC) prior to launch. The clean solar collectors were installed and the canister closed in the cleanroom to preserve collector cleanliness. The canister remained closed until opened on station at Earth-Sun L1 for solar wind collection. At the conclusion of collection, the canister was again closed to preserve collector cleanliness during Earth return and re-entry. Upon impacting the dry Utah lakebed at 300 kph the science canister integrity was breached. The canister was returned to JSC. The canister shell was briefly examined, imaged, gently cleaned of dust and packaged for storage in anticipation of future detailed examination. The condition of the science canister shell noted during this brief examination is presented here. The canister interior components were packaged and stored without imaging due to time constraints.

  7. Development of an Inhaled Dry-Powder Formulation of Tobramycin Using PulmoSphere™ Technology

    PubMed Central

    Weers, Jeffry; Heuerding, Silvia

    2011-01-01

    Abstract At present, the only approved inhaled antipseudomonal antibiotics for chronic pulmonary infections in patients with cystic fibrosis (CF) are nebulized solutions. However, prolonged administration and cleaning times, high administration frequency, and cumbersome delivery technologies with nebulizers add to the high treatment burden in this patient population. PulmoSphere™ technology is an emulsion-based spray-drying process that enables the production of light porous particle, dry-powder formulations, which exhibit improved flow and dispersion from passive dry powder inhalers. This review explores the fundamental characteristics of PulmoSphere technology, focusing on the development of a dry powder formulation of tobramycin for the treatment of chronic pulmonary Pseudomonas aeruginosa (Pa) infection in CF patients. This dry powder formulation provides substantially improved intrapulmonary deposition efficiency, faster delivery, and more convenient administration over nebulized formulations. The availability of more efficient and convenient treatment options may improve treatment compliance, and thereby therapeutic outcomes in CF. PMID:21395432

  8. Effects of different cleaning treatments on heavy metal removal of Panax notoginseng (Burk) F. H. Chen.

    PubMed

    Dahui, Liu; Na, Xu; Li, Wang; Xiuming, Cui; Lanping, Guo; Zhihui, Zhang; Jiajin, Wang; Ye, Yang

    2014-01-01

    The quality and safety of Panax notoginseng products has become a focus of concern in recent years. Contamination with heavy metals is one of the important factors as to P. notoginseng safety. Cleaning treatments can remove dust, soil, impurities or even heavy metals and pesticide residues on agricultural products. But effects of cleaning treatments on the heavy metal content of P. notoginseng roots have still not been studied. In order to elucidate this issue, the effects of five different cleaning treatments (CK, no treatment; T1, warm water (50°C) washing; T2, tap water (10°C) washing; T3, drying followed by polishing; and T4, drying followed by tap water (10°C) washing) on P. notoginseng roots' heavy metal (Cu, Pb, Cd, As and Hg) contents were studied. The results showed that heavy metal (all five) content in the three parts all followed the order of hair root > rhizome > root tuber under the same treatment. Heavy metal removals were in the order of Hg > As > Pb > Cu > Cd. Removal efficiencies of the four treatments were in the order of T2 > T1 > T3 > T4. Treatments (T1-T4) could decrease the contents of heavy metal in P. notoginseng root significantly. Compared with the requirements of WM/T2-2004, P. notoginseng roots' heavy metal contents of Cu, Pb, As and Hg were safe under treatments T1 and T2. In conclusion, the cleaning process after production was necessary and could reduce the content of heavy metals significantly. Fresh P. notoginseng root washed with warm water (T2) was the most efficient treatment to remove heavy metal and should be applied in production.

  9. Investigation of the Electrical Characteristics of Al/p-Si/Al Schottky Diode

    NASA Astrophysics Data System (ADS)

    Şenarslan, Elvan; Güzeldir, Betül; Sağlam, Mustafa

    2016-04-01

    In this study, p-type Si semiconductor wafer with (100) orientation, 400 μm thickness and 1-10 Ω cm resistivity was used. The Si wafer before making contacts were chemically cleaned with the Si cleaning procedure which for remove organic contaminations were ultrasonically cleaned at acetone and methanol for 10 min respectively and then rinsed in deionized water of 18 MΩ and dried with high purity N2. Then respectively RCA1(i.e., boiling in NH3+H2O2+6H2O for 10 min at 60°C ), RCA2 (i.e., boiling in HCl+H2O2+6H2O for 10 min at 60°C ) cleaning procedures were applied and rinsed in deionized water followed by drying with a stream of N2. After the cleaning process, the wafer is immediately inserted in to the coating unit. Ohmic contact was made by evaporating of Al on the non-polished side of the p-Si wafer pieces under ~ 4,2 10-6 Torr pressure. After process evaporation, p-Si with omic contac thermally annealed 580°C for 3 min in a quartz tube furnace in N2. Then, the rectifier contact is made by evaporation Al metal diameter of about 1.0 mm on the polished surface of p-Si in turbo molecular pump at about ~ 1 10-6 Torr. Consequently, Al/p-Si/Al Schottky diode was obtained. The I-V measurements of this diode performed by the use of a KEITLEY 487 Picoammeter/Voltage Source and the C-V measurements were performed with HP 4192A (50-13 MHz) LF Impedance Analyzer at room temperature and in dark.

  10. Improved Understanding of In Situ Chemical Oxidation Contaminant Oxidation Kinetics

    DTIC Science & Technology

    2007-12-01

    natural oxidant demand •OH hydroxide radical Ox oxidant O3 ozone PCE perchloroethylene HSO5− peroxymonosulfate PNDA p...properties (e.g., soil mineralogy , natural carbon content) affect oxidant mobility and stability in the subsurface, and develop a standardized natural...chlorinated ethenes For contaminant oxidation by activated S2O82−, it is more difficult to develop a general description of kobs vs. T because there are

  11. Next-Generation Fire Extinguishing Agent. Phase 4. Foundation for New Training Agent Development

    DTIC Science & Technology

    1989-12-01

    Administration PCE perchloroethylene PEL Permissible Exposure Limit QSAR Quantitative Structure Activity Relationship SBUV Solar Backscatter Ultraviolet xi...can pass through the troposphere without destruction to enter the stratosphere. In the stratosphere, they photolyze in the intense solar radiation to...radiation, UV-B, striking the earth. Preliminary data from a Solar Backscatter Ultraviolet (SBUV) instrument aboard NASA’s Nimbus 7 satellite show a

  12. Volatile halocarbons in butter: elevated tetrachloroethylene levels in samples obtained in close proximity to dry-cleaning establishments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, L.J.; Uhler, A.D.

    1988-09-01

    In recent years materials not directly associated with food production, such as polychlorinated and brominated biphenyls, have been found in foods. According to the criteria to evaluate the likelihood for a chemical to contaminate food, the volatile halocarbons (VHCs) were selected as target compounds in an examination for potential contaminants in selected foods. The technique of multiple headspace extraction (MHE) was used in this study to minimize sample handling, and thereby reduce the potential for laboratory contamination and maximize throughput. Recently this laboratory reported findings of several VHCs in margarine, including PCE in four samples at levels above the usualmore » background findings. Those samples had been obtained from a food store located immediately next to a dry-cleaning establishment. Follow-up investigation was conducted to determine the frequency of occurrence and levels of PCE that may be present in fatty foods purchased from stores located both near and distant from dry cleaners. Butter was chosen as a model food because it is a highly uniform product of very high fat content, which would be expected to act as a good absorber of the lipophilic VHCs. This paper presents results of these analyses and correlations between level of VHCs in butter and the proximity to dry cleaners of the food store where the butter was purchased.« less

  13. 7 CFR 1215.13 - Process.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE POPCORN PROMOTION, RESEARCH, AND CONSUMER INFORMATION Popcorn Promotion, Research, and Consumer Information Order Definitions § 1215.13 Process. Process means to shell, clean, dry, and prepare popcorn for the market, but does not include...

  14. 7 CFR 1215.13 - Process.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE POPCORN PROMOTION, RESEARCH, AND CONSUMER INFORMATION Popcorn Promotion, Research, and Consumer Information Order Definitions § 1215.13 Process. Process means to shell, clean, dry, and prepare popcorn for the market, but does not include...

  15. 7 CFR 1215.13 - Process.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE POPCORN PROMOTION, RESEARCH, AND CONSUMER INFORMATION Popcorn Promotion, Research, and Consumer Information Order Definitions § 1215.13 Process. Process means to shell, clean, dry, and prepare popcorn for the market, but does not include...

  16. 7 CFR 1215.13 - Process.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE POPCORN PROMOTION, RESEARCH, AND CONSUMER INFORMATION Popcorn Promotion, Research, and Consumer Information Order Definitions § 1215.13 Process. Process means to shell, clean, dry, and prepare popcorn for the market, but does not include...

  17. 7 CFR 1215.13 - Process.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE POPCORN PROMOTION, RESEARCH, AND CONSUMER INFORMATION Popcorn Promotion, Research, and Consumer Information Order Definitions § 1215.13 Process. Process means to shell, clean, dry, and prepare popcorn for the market, but does not include...

  18. Microbiological cleanliness of the Mars Exploration Rover spacecraft

    NASA Technical Reports Server (NTRS)

    Newlin, L.; Barengoltz, J.; Chung, S.; Kirschner, L.; Koukol, R.; Morales, F.

    2002-01-01

    Planetary protection for Mars missions is described, and the approach being taken by the Mars Exploration Rover Project is discussed. Specific topics include alcohol wiping, dry heat microbial reduction, microbiological assays, and the Kennedy Space center's PHSF clean room.

  19. Montana Advanced Biofuels Great Falls Approval

    EPA Pesticide Factsheets

    This November 20, 2015 letter from EPA approves the petition from Montana Advanced Biofuels, LLC, Great Falls facility, regarding ethanol produced through a dry mill process, qualifying under the Clean Air Act for advanced biofuel (D-code 5) and renewable

  20. 40 CFR 406.60 - Applicability; description of the parboiled rice processing subcategory.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... parboiled rice processing subcategory. 406.60 Section 406.60 Protection of Environment ENVIRONMENTAL... Rice Processing Subcategory § 406.60 Applicability; description of the parboiled rice processing... rice is cleaned, cooked and dried before being milled. ...

  1. Compression stockings

    MedlinePlus

    ... medical supply store or online. Wash Your Stockings Every Day Keep the stockings clean: Wash the stockings each ... can, have two pairs. Wear one pair each day. Wash and dry the other pair. Replace your stockings every 3 to 6 months so that they maintain ...

  2. 7 CFR 1215.12 - Popcorn.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false Popcorn. 1215.12 Section 1215.12 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING AGREEMENTS... States by shelling, cleaning, or drying, and introduced into a channel of commerce. ...

  3. CORN, LP Goldfield Approval

    EPA Pesticide Factsheets

    This November 19, 2015 letter from EPA approves the petition from CORN, LP, Goldfield facility, regarding non-grandfathered ethanol produced through a dry mill process, qualifying under the Clean Air Act for renewable fuel (D-code 6) RINs under the RFS pro

  4. Self-cleaning and self-sanitizing coatings on plastic fabrics: design, manufacture and performance.

    PubMed

    Barletta, M; Vesco, S; Tagliaferri, V

    2014-08-01

    Self-cleaning and self-sanitizing coatings are of utmost interest in several manufacturing domains. In particular, fabrics and textile materials are often pre-treated by impregnation or incorporation with antimicrobial pesticides for protection purposes against bacteria and fungi that are pathogenic for man or other animals. In this respect, the present investigation deals with the design and manufacture of self-cleaning and self-sanitizing coatings on plastic fabrics. The functionalization of the coatings was yield by incorporating active inorganic matter alone (i.e., photo-catalytic TiO2 anatase and Ag(+) ions) inside an organic inorganic hybrid binder. The achieved formulations were deposited on coextruded polyvinylchloride-polyester fabrics by air-mix spraying and left to dry at ambient temperature. The performance of the resulting coatings were characterized for their self-cleaning and self-sanitizing ability according to standardized testing procedure and/or applicable international regulations. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Effects of Contamination and Cleaning on Parachute Structural Textile Elements

    NASA Technical Reports Server (NTRS)

    Mollmann, Catherine

    2017-01-01

    Throughout their lifecycle, parachute textiles come into contact with various other substances. This contact may occur during manufacturing and repair, storage and transportation, packing, or actual use. While this interaction does not always result in negative repercussions, it may cause a loss in material strength. This paper examines the strength degradation due to several contaminants as well as the effects of cleaning agents on common parachute materials. Materials tested were: Kevlar cord and webbing, Nylon broadcloth and webbing, and Vectran cord; all of these constitute the major structural elements for CPAS (Capsule Parachute Assembly System), the parachute system for the NASA Orion Crew Module. Contaminants tested were: sewing machine oil, dried stamping ink, dirt, basting glue, Sergene, and rust. Recommendations for cleaning (or not cleaning) these materials with respect to each of the contaminants are given in this paper, as well as recommendations for future tests.

  6. Contact lens strategies for the patient with dry eye.

    PubMed

    Sindt, Christine W; Longmuir, Reid A

    2007-10-01

    Dry eye is the most common reason for contact lens (CL) discontinuation, and the patient with pre-existing dry eye presents particular challenges to the CL fitter. Poor tear film quality/stability, oxygen deprivation, lens deposits, and adverse reactions to CL solutions all contribute to dry eye, and lid disease, allergies, environmental factors, and medications can further hamper successful CL wear by the patient with dry eye. Health and comfort of the ocular surface is affected by the water content, ionicity, oxygen permeability, and modulus of elasticity of the lens, as well as by surface characteristics, such as protein, lipid, and mucin deposition; protein adsorption; and wettability. The choice of CL cleaning solutions with regard to action, cytotoxicity, and biocompatibility are as important as the choice of the CL itself. With appropriate management of the lid, meibomian gland, and ocular surface conditions that produce dry eye, careful selection of lenses and solutions, and vigilant follow-up, successful CL wear should be achievable for the dry eye patient.

  7. Rapid, economical qualitative method for separation of aflatoxins B-1, B-2 & G-1, G-2 by dry column chromatography.

    PubMed

    Megalla, S E

    1983-12-01

    A good correlation of four components of aflatoxins was accomplished by using the dry column chromatography method. The decolorization process of interfering substances, by 0.01 N KOH and defatting the extract with petroleum ether yields a clean residue for DCC separation. It is clear that the dry column chromatography is a very simple and time-saving procedure for separation of aflatoxins. DCC columns are more economical than precoated 'thick layer' preparative plates and, in DCC, no large developing tanks need to be used. Hazards associated with the use of large volumes of flammable solvents are greatly reduced.

  8. Testing sugar maple sap for sweetness with a refractometer

    Treesearch

    H. Clay Smith; George M. Keiser

    1971-01-01

    We studied the consistency of refractometer sugar readings as influenced by sap evaporation, temperature, and the drying, cleaning, and calibration of the instrument. From the study results, we suggest field procedures for using the refractometer to insure reliable measurements.

  9. 40 CFR 52.1670 - Identification of plan.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... GHG Tailoring Rule at 75 FR 31514, 31606 (June 3, 2010). Part 232, Dry Cleaning 8/11/83 6/17/85, 50 FR.... Lehigh Northeast Cement, Lehigh Cement Kiln and Clinker cooler Permit Id 5-5205-00013, effective 7/5/12 8...

  10. 40 CFR 710.43 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Definitions. 710.43 Section 710.43 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT TSCA... enterprise providing saleable goods or services (e.g., dry cleaning establishment, painting contractor...

  11. 75 FR 10242 - Tennessee Gas Pipeline Company; Notice of Availability of the Environmental Assessment for the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-05

    ... Jersey; Installation of associated appurtenant aboveground facilities including mainline valves and pig \\2\\ launchers/receivers; and \\2\\ A pig is an internal tool that can be used to clean and dry a...

  12. Efficient continuous dryer for flexible polyurethane foam and cleaning apparatus

    DOEpatents

    Jody, Bassam; Daniels, Edward; Libera, Joseph A.

    1999-01-01

    A method of cleaning polyurethane foams where the material is transported through a wash station while alternately soaking the polyurethane foam in an organic solvent and squeezing solvent from the polyurethane foam a number of times. Then the polyurethane foam is sent through a rinse or solvent transfer station for reducing the concentration of solvent in the foam. The rinsed polyurethane foam is sent to a drying station wherein the foam is repeatedly squeezed while being exposed to hot air to remove wet air from the foam.

  13. Efficient continuous dryer for flexible polyurethane foam and cleaning apparatus

    DOEpatents

    Jody, B.; Daniels, E.; Libera, J.A.

    1999-03-16

    A method of cleaning polyurethane foams where the material is transported through a wash station while alternately soaking the polyurethane foam in an organic solvent and squeezing solvent from the polyurethane foam a number of times. Then the polyurethane foam is sent through a rinse or solvent transfer station for reducing the concentration of solvent in the foam. The rinsed polyurethane foam is sent to a drying station wherein the foam is repeatedly squeezed while being exposed to hot air to remove wet air from the foam. 4 figs.

  14. Characterization of the Aerobic Oxidation of cis-Dichloroethene and Vinyl Chloride in Support of Bioremediation of Chloroethene-Contaminated Sites

    DTIC Science & Technology

    2004-11-05

    perchloroethylene) PCR polymerase chain reaction SERDP Strategic Environmental Research and Development Program TCE trichloroethene VC vinyl chloride iv...from one of the enrichments, which was inoculated with activated carbon from a pump-and-treat plant (Dortmund, Germany) processing chloroethene...dependent enzyme activity in extracts from VC and ethene-grown cells 8 (Coleman and Spain, 2003a). PCR amplifications using primers targeted at

  15. Changes on sewage sludge stability after greenhouse drying

    NASA Astrophysics Data System (ADS)

    Soriano-Disla, J. M.; Houot, S.; Imhoff, M.; Valentin, N.; Gómez, I.; Navarro-Pedreño, J.

    2009-04-01

    The progressive implementation of the Urban Waste Water Treatment Directive 91/271/EEC in all the European member states is increasing the quantities of sewage sludge requiring disposal. Sludge application onto cultivated soils as organic fertilizers allows the recycling of nutrients. The application of only dehydrated sludges has generated many problems including unpleasant odours and difficult management (regarding transport and application) related to their high water content. One way to overcome these problems, in a cheap and clean way, is the drying of sludges using the energy of the sun under greenhouse conditions. This drying may affect sludge chemical characteristics including organic matter stability and nitrogen availability, parameters which have to be controlled for the proper management of dry sludge application onto soils. For this reason, the main aim of this work was to study the impact of greenhouse drying of different sewage sludges on their organic matter stability and nitrogen availability, assessed by biochemical fractionation and mineralization assays. Three sewage sludges were sampled before (dehydrated sludges) and after greenhouse drying (dried sludges). The analyses consisted of: humidity, organic matter, mineral and organic N contents, N and C mineralization during 91-day laboratory incubations in controlled conditions, and biochemical fractionation using the Van Soest procedure. Greenhouse drying decreased the water content from 70-80% to 10% and also the odours, both of which will improve the management of the final product from the perspective of application and transport. We also found that drying reduced the organic matter content of the sludges but not the biodegradability of the remaining carbon. Organic N mineralization occurred during greenhouse drying, explaining why mineral N content tended to increase and the potential mineralization of organic nitrogen decreased after greenhouse drying. The biochemical stability did not change so much except for the one of the sludges, which experienced an important reduction. According to the results, and from a point of view of future soil applications, the balance of the drying process could be considered as positive. It is using a free, renewable and clean energy, which reduces the water content and odours of sludge, thereby improving their management. Except for the water content, there was little modification of the behaviour in soil of greenhouse dried sludges compared to the dehydrated sludges, maintaining its large amount of available nitrogen after drying. Acknowledgements: Jose. M. Soriano-Disla gratefully acknowledges the Spanish Ministry of Innovation and Culture for a research fellowship (AP2005-0320).

  16. LCA to choose among alternative design solutions: the case study of a new Italian incineration line.

    PubMed

    Scipioni, A; Mazzi, A; Niero, M; Boatto, T

    2009-09-01

    At international level LCA is being increasingly used to objectively evaluate the performances of different Municipal Solid Waste (MSW) management solutions. One of the more important waste management options concerns MSW incineration. LCA is usually applied to existing incineration plants. In this study LCA methodology was applied to a new Italian incineration line, to facilitate the prediction, during the design phase, of its potential environmental impacts in terms of damage to human health, ecosystem quality and consumption of resources. The aim of the study was to analyse three different design alternatives: an incineration system with dry flue gas cleaning (without- and with-energy recovery) and one with wet flue gas cleaning. The last two technological solutions both incorporating facilities for energy recovery were compared. From the results of the study, the system with energy recovery and dry flue gas cleaning revealed lower environmental impacts in relation to the ecosystem quality. As LCA results are greatly affected by uncertainties of different types, the second part of the work provides for an uncertainty analysis aimed at detecting the extent output data from life cycle analysis are influenced by uncertainty of input data, and employs both qualitative (pedigree matrix) and quantitative methods (Monte Carlo analysis).

  17. Effect of surface treatment on unalloyed titanium implants: spectroscopic analyses.

    PubMed

    Kilpadi, D V; Raikar, G N; Liu, J; Lemons, J E; Vohra, Y; Gregory, J C

    1998-06-15

    Surgical implant finishing and sterilization procedures were investigated to determine surface characteristics of unalloyed titanium (Ti). All specimens initially were cleaned with phosphoric acid and divided into five groups for comparisons of different surface treatments (C = cleaned as above, no further treatment; CP = C and passivated in nitric acid; CPS = CP and dry-heat sterilized; CPSS = CPS and resterilized; CS = C and dry-heat sterilized). Auger (AES), X-ray photoelectron (XPS), and Raman spectroscopic methods were used to examine surface compositions. The surface oxides formed by all treatments primarily were TiO2, with some Ti2O3 and possibly TiO. Significant concentrations of carbonaceous substances also were observed. The cleaning procedure alone resulted in residual phosphorus, primarily as phosphate groups along with some hydrogen phosphates. A higher percentage of physisorbed water appeared to be associated with the phosphorus. Passivation (with HNO3) alone removed phosphorus from the surface; specimens sterilized without prior passivation showed the thickest oxide and phosphorus profiles, suggesting that passivation alters the oxide characteristics either directly by altering the oxide structure or indirectly by removing moieties that alter the oxide. Raman spectroscopy showed no crystalline order in the oxide. Carbon, oxygen, phosphorus, and nitrogen presence were found to correlate with previously determined surface energy.

  18. Cleaning and other control and validation strategies to prevent allergen cross-contact in food-processing operations.

    PubMed

    Jackson, Lauren S; Al-Taher, Fadwa M; Moorman, Mark; DeVries, Jonathan W; Tippett, Roger; Swanson, Katherine M J; Fu, Tong-Jen; Salter, Robert; Dunaif, George; Estes, Susan; Albillos, Silvia; Gendel, Steven M

    2008-02-01

    Food allergies affect an estimated 10 to 12 million people in the United States. Some of these individuals can develop life-threatening allergic reactions when exposed to allergenic proteins. At present, the only successful method to manage food allergies is to avoid foods containing allergens. Consumers with food allergies rely on food labels to disclose the presence of allergenic ingredients. However, undeclared allergens can be inadvertently introduced into a food via cross-contact during manufacturing. Although allergen removal through cleaning of shared equipment or processing lines has been identified as one of the critical points for effective allergen control, there is little published information on the effectiveness of cleaning procedures for removing allergenic materials from processing equipment. There also is no consensus on how to validate or verify the efficacy of cleaning procedures. The objectives of this review were (i) to study the incidence and cause of allergen cross-contact, (ii) to assess the science upon which the cleaning of food contact surfaces is based, (iii) to identify best practices for cleaning allergenic foods from food contact surfaces in wet and dry manufacturing environments, and (iv) to present best practices for validating and verifying the efficacy of allergen cleaning protocols.

  19. Testing the cleaning effectiveness of new ecological aqueous dispersions applied on old icons

    NASA Astrophysics Data System (ADS)

    Vasilache, Viorica; Sandu, Irina Crina Anca; Pruteanu, Silvea; Caldeira, Ana Teresa; Simionescu, Atena Elena; Sandu, Ion

    2016-03-01

    Adherent deposits are very aggressive towards ancient heritage paintings since they affect the varnish and the painting's layers, sometimes reaching the preparative layers. The biggest problem to the restorer is their removal without affecting the patina, the transparent varnish (well preserved) and fine colour glazes made during painting. Therefore, their removal requires preliminary cleaning tests that allow the optimization of the cleaning system composition that is going to be used. The study was focused on organic natural systems, as colourless supernatants, some of them used during ages, but insufficiently studied. The paper presents an evaluation of the effectiveness of cleaning varnished icons of the nineteenth century, with complex conservation cases using supernatants derived from aqueous dispersions extracted from vegetables and dry indigenous herbal infusions. Best results, after six consecutive cleaning steps, on tempera old icon was obtained for a mixture made of mature white onion juice + extract of Soapwort flowers + corn silk tea + acacia tea. As a best result after just one cleaning step was obtained for a quaternary mixture composed from mature white onion juice + mature carrot juice + corn silk tea + aqueous extract of Soapwort flowers.

  20. 19. VIEW OF THE DIAMOND HEADFRAME LOOKING SOUTHEAST FROM THE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    19. VIEW OF THE DIAMOND HEADFRAME LOOKING SOUTHEAST FROM THE TOP OF BUTTE HILL. THE DRIES ARE ON THE LEFT, WITH THE TAR HOUSE, TOILET, AND ROPE CLAMP CLEANING TO THE RIGHT - Butte Mineyards, Diamond Mine, Butte, Silver Bow County, MT

  1. 1. GENERAL VIEW OF THE DIAMOND MINEYARD LOOKING NORTHWEST SHOWING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. GENERAL VIEW OF THE DIAMOND MINEYARD LOOKING NORTHWEST SHOWING THE DRIES ON THE LEFT, TAR STORAGE AND TOILET FACILITIES IN THE CENTER, AND A ROPE CLEANING HOUSE ON THE RIGHT - Butte Mineyards, Diamond Mine, Butte, Silver Bow County, MT

  2. 77 FR 32133 - National Register of Historic Places; Notification of Pending Nominations and Related Actions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-31

    ..., 1201 Eye St. NW., 8th floor, Washington, DC 20005; or by fax, 202-371-6447. Written or faxed comments... CAROLINA Durham County Scott and Roberts Dry Cleaning Plant, Office, and Store, 733 Foster St., Durham...

  3. 40 CFR 52.1670 - Identification of plan.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (June 3, 2010). Part 232, Dry Cleaning 8/11/83 6/17/85, 50 FR 25079 EPA has not determined that § 232.3.... Lehigh Northeast Cement, Lehigh Cement Kiln and Clinker cooler Permit Id 5-5205-00013, effective 7/5/12 8...

  4. Dalhousie Fire

    ERIC Educational Resources Information Center

    Matthews, Fred W.

    1986-01-01

    Describes steps taken by the Weldon Law Library at Dalhousie University in salvaging books damaged in a major fire, including procedures and processes used in packing, sorting, drying, and cleaning the books. The need for a disaster plan for specific libraries is emphasized, and some suggestions are made. (CDD)

  5. 40 CFR 35.918 - Individual systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... STATE AND LOCAL ASSISTANCE Grants for Construction of Treatment Works-Clean Water Act § 35.918... commercial establishment with waste water flow equal to or smaller than one user equivalent (generally 300 gallons per day dry weather flows) is included. (3) Small commercial establishments. Private...

  6. Emissions from gas fired agricultural burners

    USDA-ARS?s Scientific Manuscript database

    Because of the Federal Clean Air Act, the San Joaquin Valley Unified Air Pollution Control District (SJVUAPCD) began defining Best Available Control Technology (BACT) for NOx emissions from cotton gin drying system gas fired burners in its jurisdiction. The NOx emission levels of conventionally used...

  7. Cleaning painted surfaces: evaluation of leaching phenomenon induced by solvents applied for the removal of gel residues.

    PubMed

    Casoli, Antonella; Di Diego, Zaira; Isca, Clelia

    2014-12-01

    Cleaning is one of the most important, delicate, and at the same time controversial processes in the conservation treatment of paintings. Although a strict definition of cleaning would be the removal of dirt, grime, or other accretions (surface cleaning), in the conservation field, cleaning is used in the broader meaning to include thinning/removing altered or “unwanted layers” of materials without damaging or altering the physicochemical properties of the surfaces to be preserved. The cleaning of unvarnished paintings is one of the most critical issues that are currently discussed. Several studies exist regarding different cleaning tools, such as gels, soaps, enzymes, ionic liquids, and foams, as well as various dry methods and lasers, but only a few have been performed on the risk associated with the use of water and organic solvents for the cleaning treatments in relation to the original paint binder. The aim of the study is to verify analytically the behavior of water gelling agents during cleaning treatments and the interaction of the following elements: water or organic solvents applied for the removal of gel residues with the original lipid paint binder. For this purpose, the study was conducted on a fragment of canvas painting (sixteenth to seventeenth century) of Soprintendenza per i Beni Storici, Artistici ed Etnoantropologici del Friuli Venezia Giulia (Superintendence for the Historical, Artistic and Ethno-anthropological Heritage of Friuli Venezia Giulia), Udine by means of Fourier transform infrared spectroscopy, gas chromatography/mass spectrometry, and scanning electron microscopy.

  8. Staying sticky: contact self-cleaning of gecko-inspired adhesives.

    PubMed

    Mengüç, Yigit; Röhrig, Michael; Abusomwan, Uyiosa; Hölscher, Hendrik; Sitti, Metin

    2014-05-06

    The exceptionally adhesive foot of the gecko remains clean in dirty environments by shedding contaminants with each step. Synthetic gecko-inspired adhesives have achieved similar attachment strengths to the gecko on smooth surfaces, but the process of contact self-cleaning has yet to be effectively demonstrated. Here, we present the first gecko-inspired adhesive that has matched both the attachment strength and the contact self-cleaning performance of the gecko's foot on a smooth surface. Contact self-cleaning experiments were performed with three different sizes of mushroom-shaped elastomer microfibres and five different sizes of spherical silica contaminants. Using a load-drag-unload dry contact cleaning process similar to the loads acting on the gecko foot during locomotion, our fully contaminated synthetic gecko adhesives could recover lost adhesion at a rate comparable to that of the gecko. We observed that the relative size of contaminants to the characteristic size of the microfibres in the synthetic adhesive strongly determined how and to what degree the adhesive recovered from contamination. Our approximate model and experimental results show that the dominant mechanism of contact self-cleaning is particle rolling during the drag process. Embedding of particles between adjacent fibres was observed for particles with diameter smaller than the fibre tips, and further studied as a temporary cleaning mechanism. By incorporating contact self-cleaning capabilities, real-world applications of synthetic gecko adhesives, such as reusable tapes, clothing closures and medical adhesives, would become feasible.

  9. Staying sticky: contact self-cleaning of gecko-inspired adhesives

    PubMed Central

    Mengüç, Yiğit; Röhrig, Michael; Abusomwan, Uyiosa; Hölscher, Hendrik; Sitti, Metin

    2014-01-01

    The exceptionally adhesive foot of the gecko remains clean in dirty environments by shedding contaminants with each step. Synthetic gecko-inspired adhesives have achieved similar attachment strengths to the gecko on smooth surfaces, but the process of contact self-cleaning has yet to be effectively demonstrated. Here, we present the first gecko-inspired adhesive that has matched both the attachment strength and the contact self-cleaning performance of the gecko's foot on a smooth surface. Contact self-cleaning experiments were performed with three different sizes of mushroom-shaped elastomer microfibres and five different sizes of spherical silica contaminants. Using a load–drag–unload dry contact cleaning process similar to the loads acting on the gecko foot during locomotion, our fully contaminated synthetic gecko adhesives could recover lost adhesion at a rate comparable to that of the gecko. We observed that the relative size of contaminants to the characteristic size of the microfibres in the synthetic adhesive strongly determined how and to what degree the adhesive recovered from contamination. Our approximate model and experimental results show that the dominant mechanism of contact self-cleaning is particle rolling during the drag process. Embedding of particles between adjacent fibres was observed for particles with diameter smaller than the fibre tips, and further studied as a temporary cleaning mechanism. By incorporating contact self-cleaning capabilities, real-world applications of synthetic gecko adhesives, such as reusable tapes, clothing closures and medical adhesives, would become feasible. PMID:24554579

  10. A design of experiments test to define critical spray cleaning parameters for Brulin 815 GD and Jettacin cleaners

    NASA Technical Reports Server (NTRS)

    Keen, Jill M.; Evans, Kurt B.; Schiffman, Robert L.; Deweese, C. Darrell; Prince, Michael E.

    1995-01-01

    Experimental design testing was conducted to identify critical parameters of an aqueous spray process intended for cleaning solid rocket motor metal components (steel and aluminum). A two-level, six-parameter, fractional factorial matrix was constructed and conducted for two cleaners, Brulin 815 GD and Diversey Jettacin. The matrix parameters included cleaner temperature and concentration, wash density, wash pressure, rinse pressure, and dishwasher type. Other spray parameters: nozzle stand-off, rinse water temperature, wash and rinse time, dry conditions, and type of rinse water (deionized) were held constant. Matrix response testing utilized discriminating bond specimens (fracture energy and tensile adhesion strength) which represent critical production bond lines. Overall, Jettacin spray cleaning was insensitive to the range of conditions tested for all parameters and exhibited bond strengths significantly above the TCA test baseline for all bond lines tested. Brulin 815 was sensitive to cleaning temperature, but produced bond strengths above the TCA test baseline even at the lower temperatures. Ultimately, the experimental design database was utilized to recommend process parameter settings for future aqueous spray cleaning characterization work.

  11. In situ dc oxygen‐discharge cleaning system for optical elements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koide, Tsuneharu; Shidara, Tetsuo; Tanaka, Kenichiro

    1989-07-15

    In situ dc oxygen‐discharge cleaning arrangements have been developed at the Photon Factory for the removal of carbon contamination from optical surfaces. A high cleaning rate could be achieved by producing an oxygen plasma close to the optical elements with special care taken to avoid any harmful effects from the discharge; contaminant carbon was completely removed within a few hours, at most. This short exposure time and the use of dry oxygen gas resulted in a restoration of the original ultrahigh vacuum without a bakeout. Results with a Seya‐Namioka beamline for gas‐phase experiments showed a flux enhancement amounting to amore » factor of 50, and results with a grasshopper beamline showed a nearly complete recovery of the light intensity, even at the carbon K edge.« less

  12. Fabrication of Polyvinylpyrrolidone Micro-/Nanostructures Utilizing Microcontact Printing

    ERIC Educational Resources Information Center

    Sanders, Wesley C.

    2015-01-01

    This paper describes a laboratory exercise that provides students enrolled in introductory nanotechnology courses with an opportunity to synthesize polymer structures with micro- and nanoscale dimensions. Polyvinylpyrrolidone (PVP) films deposited on corrugated PDMS stamps using student-built spin coaters were transferred to clean, dry substrates…

  13. 7 CFR 58.127 - Facilities.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... both hot and cold water of safe and sanitary quality, with adequate facilities for its proper.... Convenient hand-washing facilities shall be provided, including hot and cold running water, soap or other... regularly and the containers cleaned before reuse. Accumulation of dry waste paper and cardboard shall be...

  14. 7 CFR 58.127 - Facilities.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... both hot and cold water of safe and sanitary quality, with adequate facilities for its proper.... Convenient hand-washing facilities shall be provided, including hot and cold running water, soap or other... regularly and the containers cleaned before reuse. Accumulation of dry waste paper and cardboard shall be...

  15. 7 CFR 58.127 - Facilities.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... both hot and cold water of safe and sanitary quality, with adequate facilities for its proper.... Convenient hand-washing facilities shall be provided, including hot and cold running water, soap or other... regularly and the containers cleaned before reuse. Accumulation of dry waste paper and cardboard shall be...

  16. 7 CFR 58.127 - Facilities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... both hot and cold water of safe and sanitary quality, with adequate facilities for its proper.... Convenient hand-washing facilities shall be provided, including hot and cold running water, soap or other... regularly and the containers cleaned before reuse. Accumulation of dry waste paper and cardboard shall be...

  17. 77 FR 42700 - Procurement List; Additions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-20

    ...-NIB-0011--Splitting Maul--6 lb, Sledge Eye, 36'' Fiberglass Handle NSN: 5120-00-NIB-0012--Splitting Maul--8 lb, Sledge Eye, 36'' Fiberglass Handle NSN:: Keystone Vocational Services, Inc., Sharon, PA... Service Type/Location: Laundry and Dry Cleaning Service, Buckley AFB Lodging & Medical Facilities, Buckley...

  18. 7 CFR 58.510 - Rooms and compartments.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... avoided. Rooms, compartments, coolers, and dry storage space in which any raw material, packaging or... contamination. (d) Coolers. Coolers shall be equipped with facilities for maintaining proper temperature and... quality and condition of the products. Coolers shall be kept clean, orderly and free from mold, and...

  19. 7 CFR 58.510 - Rooms and compartments.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... avoided. Rooms, compartments, coolers, and dry storage space in which any raw material, packaging or... contamination. (d) Coolers. Coolers shall be equipped with facilities for maintaining proper temperature and... quality and condition of the products. Coolers shall be kept clean, orderly and free from mold, and...

  20. 7 CFR 58.510 - Rooms and compartments.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... avoided. Rooms, compartments, coolers, and dry storage space in which any raw material, packaging or... contamination. (d) Coolers. Coolers shall be equipped with facilities for maintaining proper temperature and... quality and condition of the products. Coolers shall be kept clean, orderly and free from mold, and...

  1. 7 CFR 58.510 - Rooms and compartments.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... avoided. Rooms, compartments, coolers, and dry storage space in which any raw material, packaging or... contamination. (d) Coolers. Coolers shall be equipped with facilities for maintaining proper temperature and... quality and condition of the products. Coolers shall be kept clean, orderly and free from mold, and...

  2. 7 CFR 58.510 - Rooms and compartments.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... avoided. Rooms, compartments, coolers, and dry storage space in which any raw material, packaging or... contamination. (d) Coolers. Coolers shall be equipped with facilities for maintaining proper temperature and... quality and condition of the products. Coolers shall be kept clean, orderly and free from mold, and...

  3. Infant Formula - Buying, Preparing, Storing, and Feeding

    MedlinePlus

    ... formula in a cool, dry place with a plastic lid on top. DO NOT use outdated formula. Always wash your hands and the top of the formula container before handling. Use a clean cup to measure the water. Make the formula as directed. DO NOT water ...

  4. 7 CFR 800.187 - Conflicts of interest

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... courtesies of nominal value in a business or work relationship if the exchange is wholly free of any... relationship, rather than a business or work relationship. (c) Conflicts. In addition to the conflicts of... business by buying, selling, transporting, cleaning, elevating, storing, binning, mixing, blending, drying...

  5. Beyond Tomorrow - A Look at 2050 A.D.

    DTIC Science & Technology

    1992-04-15

    347 Photochemical smog is created by a complex series of reac- tions between hydrocarbons released by fermenting yeast, evapo- rating dry cleaning...electricity, use mass transportation, walk and ride bicycles more, and use natural cleaners such as baking soda and vinegar instead of many commercial

  6. Fabrication of an Inexpensive Ion-Selective Electrode.

    ERIC Educational Resources Information Center

    Palanivel, A.; Riyazuddin, P.

    1984-01-01

    The preparation and performance of a graphite (silver/copper sulfide) electrode is described. This rod, extracted from a used dry cell, is an acceptable substitute for ion-selective electrodes after it has been cleaned by abrasion followed by an overnight treatment with hydrochloric acid. (JN)

  7. Target Organ Metabolism, Toxicity, and Mechanisms of Trichloroethylene and Perchloroethylene: Key Similarities, Differences, and Data Gaps

    PubMed Central

    Cichocki, Joseph A.; Guyton, Kathryn Z.; Guha, Neela; Chiu, Weihsueh A.

    2016-01-01

    Trichloroethylene (TCE) and perchloroethylene or tetrachloroethylene (PCE) are high–production volume chemicals with numerous industrial applications. As a consequence of their widespread use, these chemicals are ubiquitous environmental contaminants to which the general population is commonly exposed. It is widely assumed that TCE and PCE are toxicologically similar; both are simple olefins with three (TCE) or four (PCE) chlorines. Nonetheless, despite decades of research on the adverse health effects of TCE or PCE, few studies have directly compared these two toxicants. Although the metabolic pathways are qualitatively similar, quantitative differences in the flux and yield of metabolites exist. Recent human health assessments have uncovered some overlap in target organs that are affected by exposure to TCE or PCE, and divergent species- and sex-specificity with regard to cancer and noncancer hazards. The objective of this minireview is to highlight key similarities, differences, and data gaps in target organ metabolism and mechanism of toxicity. The main anticipated outcome of this review is to encourage research to 1) directly compare the responses to TCE and PCE using more sensitive biochemical techniques and robust statistical comparisons; 2) more closely examine interindividual variability in the relationship between toxicokinetics and toxicodynamics for TCE and PCE; 3) elucidate the effect of coexposure to these two toxicants; and 4) explore new mechanisms for target organ toxicity associated with TCE and/or PCE exposure. PMID:27511820

  8. Effects of physical interventions on house dust mite allergen levels in carpet, bed, and upholstery dust in low-income, urban homes.

    PubMed Central

    Vojta, P J; Randels, S P; Stout, J; Muilenberg, M; Burge, H A; Lynn, H; Mitchell, H; O'Connor, G T; Zeldin, D C

    2001-01-01

    House dust mite allergen exposure is a postulated risk factor for allergic sensitization, asthma development, and asthma morbidity; however, practical and effective methods to mitigate these allergens from low-income, urban home environments remain elusive. The purpose of this study was to assess the feasibility and effectiveness of physical interventions to mitigate house dust mite allergens in this setting. Homes with high levels of house dust mite allergen (Der f 1 + Der p 1 > or = 10 microg/g dust by enzyme-linked immunosorbent assay) in the bed, bedroom carpet, and/or upholstered furniture were enrolled in the study. Carpets and upholstered furniture were subjected to a single treatment of either dry steam cleaning plus vacuuming (carpet only) or intensive vacuuming alone. Bed interventions consisted of complete encasement of the mattress, box spring, and pillows plus either weekly professional or in-home laundering of nonencased bedding. Dust samples were collected at baseline and again at 3 days (carpet and upholstery only) and 2, 4, and 8 weeks posttreatment. We compared pretreatment mean allergen concentrations and loads to posttreatment values and performed between-group analyses after adjusting for differences in the pretreatment means. Both dry steam cleaning plus vacuuming and vacuuming alone resulted in a significant reduction in carpet house dust mite allergen concentration and load (p < 0.05). Levels approached pretreatment values by 4 weeks posttreatment in the intensive vacuuming group, whereas steam cleaning plus vacuuming effected a decrease that persisted for up to 8 weeks. Significant decreases in bed house dust mite allergen concentration and load were obtained in response to encasement and either professional or in-home laundering (p < 0.001). Between-group analysis revealed significantly less postintervention house dust mite allergen load in professionally laundered compared to home-laundered beds (p < 0.05). Intensive vacuuming and dry steam cleaning both caused a significant reduction in allergen concentration and load in upholstered furniture samples (p < 0.005). Based on these data, we conclude that physical interventions offer practical, effective means of reducing house dust mite allergen levels in low-income, urban home environments. PMID:11564617

  9. Towards a Spiderman suit: large invisible cables and self-cleaning releasable superadhesive materials

    NASA Astrophysics Data System (ADS)

    Pugno, Nicola M.

    2007-10-01

    Spiders can produce cobwebs with high strength to density ratio and surprisingly display self-cleaning, strong and releasable adhesion (like geckos). Nanointerlocking, capillary and van der Waals forces, all potential adhesive mechanisms, are thus discussed, demonstrating the key role played by hierarchy in the design of superhydrophobic, i.e. self-cleaning (dry or wet and enhanced by activating Fakir drops as in lotus leaves) and superadhesive materials. The reversibility of the strong attachment is quantified thanks to an improved nonlinear peeling model including friction, for which the solution in closed form is provided. Thus, mimicking nature, thanks to carbon-nanotube-based technology, we suggest the feasibility of large invisible cables, as well as of self-cleaning, superadhesive and releasable hierarchical smart materials. We found that a man can theoretically be supported by a transparent cable with cross-section of 1 cm2 and feasibly, with spider material gloves and boots, could remain attached even to a ceiling: a preliminary step towards a Spiderman suit.

  10. Removal of graffiti paintings from the Mansion de Mattis site in Corato (Bari), Italy: Laser deveiling or complete cleaning?

    NASA Astrophysics Data System (ADS)

    Daurelio, G.; Andriani, E. S.; Albanese, A.; Catalano, I. M.; Teseo, G.; Marano, D.

    2008-10-01

    Nowadays one the main problem of stone monuments conservation is not only the natural environment deterioration but the defaced, in particular esthetic, due to graffiti. This paper presents the different stages of the cleaning graffiti research: the laboratory study phase, in which the aims were to investigate the laser cleaning effect on substrate and testing user-friendly and efficient solutions for in situ application; the application phase in which the study results were applied in the restoration of Palazzo de Mattis facade. The graffiti cleaning were carried out by using a Q-Switch Nd:YAG laser source (λ=1064 nm with pulse duration, t=8 ns, f=2 to 20 Hz, energy per impulse up to 280 mJ) in dry, wet and Very wet modes adopting the Daurelio technique n.1 (blade spot laser). The Q-Switch Nd:Yag laser source has demonstrated to be the most suitable for a fully or, according to new restoring theory, "de veiling" graffiti ablation.

  11. Study of metals concentration levels in Patella piperata throughout the Canary Islands, Spain.

    PubMed

    Bergasa, Oscar; Ramírez, Rubén; Collado, Cayetano; Hernández-Brito, J Joaquín; Gelado-Caballero, María Dolores; Rodríguez-Somozas, María; Haroun, Ricardo J

    2007-04-01

    In order to assess the extent of metal contamination at rocky shores of the Canarian Archipelago, metal concentrations have been measured in Patella piperata (Gould, 1846), using the standard atomic absorption spectrophotometer technique. Ranges of elements concentrations measured (in microg g(-1)) found in the biota were: Cd (0.36 +/- 0.26 microg g(-1) dry wt.), Cu (2.05 +/- 0.91 dry wt.), Pb (1.57 +/- 1.14 microg g(-1)dry wt.) and Zn (10.37 +/- 4.60 microg g(-1) dry wt.). Variation in metal concentrations in Patella, was tested by using non-parametric statistical methods. Cd content had a maximum in the Archipelago Chinijo, northward of Lanzarote Island. The metal concentrations recorded at the clean stations may be considered carefully if they are used like background levels.

  12. Peer Review Plan for OPPT Work Plan Risk Assessment of 1 - Bromopropane (“1 - BP”)

    EPA Pesticide Factsheets

    This document outlines the peer review plan for a risk assessment which addresses occupational uses of 1-BP in dry-cleaning and foam gluing operations, consumer uses in aerosol solvent cleaners and spray adhesives, and its effects on human health.

  13. Psychological Readiness and Motor Skills Needed for Toilet Training

    MedlinePlus

    ... as dirty or messy will only make your child feel bad), but you can certainly say positive things about how good it feels and smells to be clean and dry. Your goal is to strengthen your child’s awareness of the feeling of needing to go ...

  14. INTEGRATED DEMONSTRATION OF SURFACTANT-ENHANCED AQUIFER REMEDIATION WITH SURFACTANT RECOVERY AND REUSE

    EPA Science Inventory

    The demonstration site will be the base dry cleaning facility at Camp Lejeune, North Carolina. Conservative and partitioning tracer tests will be used in conjunction with conventional core and ground-water sampling to characterize the site with respect to DNAPL composition and d...

  15. Cleaning Water Contaminated with Heavy Metal Ions Using Pyrolyzed Biochar Adsorbents

    EPA Science Inventory

    The extraction of pollutants from water using activated biochar materials is a low cost, sustainable approach for providing safe water in developing countries. The adsorption of copper ions, Cu (II), onto banana peels that were dried, pyrolyzed and activated was studied and compa...

  16. Environmental control and waste management system design concept

    NASA Technical Reports Server (NTRS)

    Gandy, A. R.

    1974-01-01

    Passive device contains both solid and liquid animal waste matter for extended period without being cleaned and without contaminating animal. Constant airflow dries solid waste and evaporates liquid matter. Technique will maintain controlled atmospheric conditions and cage cleanliness during periods of 6 months to 1 year.

  17. Mr. Wizard's Supermarket Science.

    ERIC Educational Resources Information Center

    Herbert, Don

    Activities which can be done with items purchased in supermarkets form the basis of this book. The activities are arranged into sections by type of item; breakfast foods; dried foods; soups; baking ingredients; gelatin; condiments; coffee; salad dressing; dairy products; meats; cleaning supplies; cookware; juices; picnic supplies; paper towels;…

  18. Effects of microarrangement of solid particles on PCE migration and its remediation in porous media

    NASA Astrophysics Data System (ADS)

    Wu, Ming; Wu, Jianfeng; Wu, Jichun; Hu, Bill X.

    2018-02-01

    Groundwater can be stored abundantly in granula-composed aquifers with high permeability. The microstructure of granular materials has important effect on the permeability of aquifers and the contaminant migration and remediation in aquifers is also influenced by the characteristics of porous media. In this study, two different microscale arrangements of sand particles are compared to reveal the effects of microstructure on the contaminant migration and remediation. With the help of fractal theory, the mathematical expressions of permeability and entry pressure are conducted to delineate granular materials with regular triangle arrangement (RTA) and square pitch arrangement (SPA) at microscale. Using a sequential Gaussian simulation (SGS) method, a synthetic heterogeneous site contaminated by perchloroethylene (PCE) is then used to investigate the migration and remediation affected by the two different microscale arrangements. PCE is released from an underground storage tank into the aquifer and the surfactant is used to clean up the subsurface contamination. Results suggest that RTA can not only cause more groundwater contamination, but also make remediation become more difficult. The PCE remediation efficiency of 60.01-99.78 % with a mean of 92.52 and 65.53-99.74 % with a mean of 95.83 % is achieved for 200 individual heterogeneous realizations based on the RTA and SPA, respectively, indicating that the cleanup of PCE in aquifer with SPA is significantly easier. This study leads to a new understanding of the microstructures of porous media and demonstrates how microscale arrangements control contaminant migration in aquifers, which is helpful to design successful remediation scheme for underground storage tank spill.

  19. A clean-up method by photocatalysis for HPLC analysis of iprodione in dry basil.

    PubMed

    Maeda, Osamu; Oikawa, Chie; Shiomi, Nobuo; Toriba, Akira; Hayakawa, Kazuichi

    2008-08-01

    Titanium dioxide was used as a photocatalyst to decompose interfering substances for a quantitative analysis of a fungicide (iprodione) in dry basil by HPLC. A quartz vial containing basil extract and titanium dioxide was irradiated with black light. The interfering substances were almost completely decomposed by 180 min of irradiation, whereas 88.3% of iprodione remained. The recovery of iprodione was 102.6% by the proposed method in basil extracts. This may have been due to different decomposition rates of the analyte and interfering substances.

  20. Novel Therapeutic Approaches for the Treatment of Depression and Cognitive Deficits in a Rodent Model of Gulf War Veterans Illness

    DTIC Science & Technology

    2015-10-01

    and DFP-exposed rats. There were no visual signs of pain and discomfort such as hunched posture, poor grooming, porphyrin around eyes or nose in DFP...cage. The maze was cleaned with 70% ethanol and air-dried to remove any scent traces and allowed to dry completely before introducing the next... Syndrome . A proton MR spectroscopy study. Brain Res 1009 (1-2), 189-194. 26. Odegard, T.N., Cooper, C.M., Farris, E.A., Arduengo, J., Bartlett, J. and

  1. Interruption of a dry-type transformer in no-load by a vacuum circuit-breaker

    NASA Astrophysics Data System (ADS)

    Vandenheuvel, W. M. C.; Daalder, J. E.; Boone, M. J. M.; Wilmes, L. A. H.

    1983-08-01

    Overvoltages generated during interruption of a dry type delta-star connected transformer in no load by a vacuum breaker were studied. During interruption of inrush current 37% of the phase-to-ground overvoltages were 5 pu, and 6% 7 pu. Comparison of experimental and theoretical results using Boyle's model shows no discrepancy for inrush currents and clean overvoltages from the steady-state interruption. Overvoltages due to repetitive reignitions (not covered by Boyle's model) are higher than the calculated values during steady-state switching.

  2. Laser-induced breakdown spectroscopy for analysis of plant materials: A review

    NASA Astrophysics Data System (ADS)

    Santos, Dário, Jr.; Nunes, Lidiane Cristina; de Carvalho, Gabriel Gustinelli Arantes; Gomes, Marcos da Silva; de Souza, Paulino Florêncio; Leme, Flavio de Oliveira; dos Santos, Luis Gustavo Cofani; Krug, Francisco José

    2012-05-01

    Developments and contributions of laser-induced breakdown spectroscopy (LIBS) for the determination of elements in plant materials are reviewed. Several applications where the solid samples are interrogated by simply focusing the laser pulses directly onto a fresh or dried surface of leaves, roots, fruits, vegetables, wood and pollen are presented. For quantitative purposes aiming at plant nutrition diagnosis, the test sample presentation in the form of pressed pellets, prepared from clean, dried and properly ground/homogenized leaves, and the use of univariate or multivariate calibration strategies are revisited.

  3. A new hydrogen peroxide--based medical-device detergent with germicidal properties: comparison with enzymatic cleaners.

    PubMed

    Alfa, M J; Jackson, M

    2001-06-01

    The objective of this study was to evaluate the efficacy of the cleaning and bacterial killing ability of a new non-enzyme-based formulation (killing detergent solution [KDS]) compared with commercially available enzymatic detergents that included Metrizyme (Metrex Research Division of Sybron Canada Ltd. Morrisburg, Ontario) and Gzyme (Germiphene Corp, Brantford, Ontario). KDS is a hydrogen peroxide-based detergent formulation that combines cleaning efficacy with the ability to kill microorganisms. The KDS formulation helps ensure the protection of the health care worker from infectious risk during the soaking and cleaning stages of medical device reprocessing and reduces the bioburden on devices before sterilization/disinfection. Test organisms that included Enterococcus faecalis, Salmonella choleraesuis, Staphylococcus aureus, and Pseudomonas aeruginosa were suspended in artificial test soil (ATS-B; patent submitted), inoculated at 10(6) colonyforming units per carrier and dried overnight before detergent exposure. The ATS-B mimics the blood, protein, carbohydrate, and endotoxin levels of patient-used medical devices. Plastic lumen carriers and a flexible colonoscope were used for surface and simulated-use testing, respectively. The results for the microbial challenge dried onto polyvinyl chloride (PVC) carriers demonstrated that the ability of KDS to remove protein, blood, carbohydrate, and endotoxin from surface test carriers was as effective as the enzyme detergents that were evaluated. Furthermore, KDS was able to effect approximately a 5-Log(10) reduction in microbial loads with a 3-minute exposure at room temperature, whereas none of the other detergents were as effective. In simulated-use testing of a soiled colonoscope, KDS was significantly better at ensuring microbial killing compared with Gzyme and Metrizyme and was equivalent to the enzymatic detergents in cleaning ability. In summary the KDS has excellent microbial-killing ability in 3-minute exposures at room temperature and cleans as well as the existing enzymatic detergent formulations that were tested.

  4. Cleaning of conveyor belt materials using ultrasound in a thin layer of water.

    PubMed

    Axelsson, L; Holck, A; Rud, I; Samah, D; Tierce, P; Favre, M; Kure, C F

    2013-08-01

    Cleaning of conveyor belts in the food industry is imperative for preventing the buildup of microorganisms that can contaminate food. New technologies for decreasing water and energy consumption of cleaning systems are desired. Ultrasound can be used for cleaning a wide range of materials. Most commonly, baths containing fairly large amounts of water are used. One possibility to reduce water consumption is to use ultrasonic cavitation in a thin water film on a flat surface, like a conveyor belt. In order to test this possibility, a model system was set up, consisting of an ultrasound transducer/probe with a 70-mm-diameter flat bottom, operating at 19.8 kHz, and contaminated conveyor belt materials in the form of coupons covered with a thin layer of water or water with detergent. Ultrasound was then applied on the water surface at different power levels (from 46 to 260 W), exposure times (10 and 20 s), and distances (2 to 20 mm). The model was used to test two different belt materials with various contamination types, such as biofilms formed by bacteria in carbohydrate- or protein-fat-based soils, dried microorganisms (bacteria, yeasts, and mold spores), and allergens. Ultrasound treatment increased the reduction of bacteria and yeast by 1 to 2 log CFU under the most favorable conditions compared with water or water-detergent controls. The effect was dependent on the type of belt material, the power applied, the exposure time, and the distance between the probe and the belt coupon. Generally, dried microorganisms were more easily removed than biofilms. The effect on mold spores was variable and appeared to be species and material dependent. Spiked allergens were also efficiently removed by using ultrasound. The results in this study pave the way for new cleaning designs for flat conveyor belts, with possibilities for savings of water, detergent, and energy consumption.

  5. A comparison of the effects of toothbrushing and handpiece prophylaxis on retention of sealants.

    PubMed

    Kolavic Gray, Shellie; Griffin, Susan O; Malvitz, Dolores M; Gooch, Barbara F

    2009-01-01

    Tooth surface cleaning before acid etching is considered to be an important step in the retention of resin-based pit-and-fissure sealants. The authors reviewed and summarized instructions for cleaning tooth surfaces from five manufacturers of 10 unfilled resin-based sealants marketed in the United States. The authors also searched electronic databases for studies that directly compared the effects of different surface-cleaning methods on sealant retention and for systematic reviews of the effectiveness of sealants. They explored the association between surface-cleaning methods and sealant retention in the studies included in the systematic reviews. They calculated the summary weighted retention rates for studies that used either a handpiece or toothbrush prophylaxis. All of the sealant manufacturers' instructions for use (IFU) recommended cleaning the tooth before acid etching. None of the IFU directly stated that a handpiece was required to perform the cleaning, but five IFU implied the use of handpiece prophylaxis. None of the IFU recommended surface-altering procedures in caries-free teeth. Direct evidence from two clinical trials showed no difference in complete sealant retention between surfaces cleaned mechanically with pumice or prophylaxis paste and those cleaned with air-water syringe or dry toothbrushing. Indirect evidence from 10 studies found that weighted summary retention by year after sealant placement in studies that used toothbrush prophylaxis was greater than or equivalent to values for studies that used handpiece prophylaxis. Levels of sealant retention after surface cleaning with toothbrush prophylaxis were at least as high as those associated with hand-piece prophylaxis. This finding may translate into lower resource costs for sealant placement.

  6. Optimization of Ultrasonic Fabric Cleaning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hand, T.E.

    The fundamental purpose of this project was to research and develop a process that would reduce the cost and improve the environmental efficiency of the present dry-cleaning industry. This second phase of research (see report KCP-94-1006 for information gathered during the first phase) was intended to allow the optimal integration of all factors of ultrasonic fabric cleaning. For this phase, Garment Care performed an extensive literature search and gathered data from other researchers worldwide. The Garment Care-AlliedSignal team developed the requirements for a prototype cleaning tank for studies and acquired that tank and the additional equipment required to use itmore » properly. Garment Care and AlliedSignal acquired the transducers and generators from Surftran Martin-Walter in Sterling Heights, Michigan. Amway's Kelly Haley developed the test protocol, supplied hundreds of test swatches, gathered the data on the swatches before and after the tests, assisted with the cleaning tests, and prepared the final analysis of the results. AlliedSignal personnel, in conjunction with Amway and Garment Care staff, performed all the tests. Additional planning is under way for future testing by outside research facilities. The final results indicated repeatable performance and good results for single layered fabric swatches. Swatches that were cleaned as a ''sandwich,'' that is, three or more layers.« less

  7. EVALUATION OF FGD DRY INJECTION SORBENTS AND ADDITIVES - VOLUME 1 - DEVELOPMENT OF HIGH REACTIVITY SORBENTS

    EPA Science Inventory

    The report discusses recent work addressing lime enhancement by slurrying with siliceous materials and testing in a laboratory packed-bed reactor, as part of EPA's efforts to develop low cost, retrofit flue gas cleaning technology, including the development of highly reactive sor...

  8. Monitoring Alkyl Phenol Ethoxylates And Degradation Products After Land Application Of Anaerobically Digested Biosolids

    EPA Science Inventory

    Annually, over 3 million dry tons of treated sewage sludge (or biosolids) are applied on agricultural lands in the U.S. In 2002, the National Research Council (NRC) recommended an examination of biosolids management practices including chemicals such as surfactants used in clean...

  9. An Intercomparison of the Deposition Models Used in the CASTNET and CAPMoN Networks

    EPA Science Inventory

    To assess long-term trends in atmospheric deposition, the U.S. operates the Clean Air Status and Trends Network (CASTNET) and Canada operates the Canadian Air and Precipitation Monitoring Network (CAPMoN). Both networks use modeled dry deposition velocities and measured atmospher...

  10. Conservation of Drawings and Prints

    ERIC Educational Resources Information Center

    King, Antoinette

    1972-01-01

    Some of the basic techniques of preserving and restoring prints and drawings are outlined. Examination, dry cleaning, stain removal, mending, backing removal, and lining are discussed, as well as aspects of the complexity of bleaching, types and nature of some stains and discolorations, and materials of poor quality used by many framers. (Author)

  11. 7 CFR 58.128 - Equipment and utensils.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... contact surfaces of all utensils and equipment such as holding tanks, pasteurizers, coolers, vats... discharge a clean dry can and cover and shall be kept properly timed in accordance with the instructions of..., signature or initials of operator. (i) Surface coolers. Surface coolers shall be equipped with hinged or...

  12. 7 CFR 58.128 - Equipment and utensils.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... contact surfaces of all utensils and equipment such as holding tanks, pasteurizers, coolers, vats... discharge a clean dry can and cover and shall be kept properly timed in accordance with the instructions of..., signature or initials of operator. (i) Surface coolers. Surface coolers shall be equipped with hinged or...

  13. 40 CFR 63.325 - Determination of equivalent emission control technology.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... other than the specific system(s) examined; and (7) Information on the cross-media impacts (to water and..., and submit to the Administrator the following information to show that the alternative achieves...) and their ancillary equipment during each portion of the normal dry cleaning cycle; (2) Information...

  14. 40 CFR 63.325 - Determination of equivalent emission control technology.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... other than the specific system(s) examined; and (7) Information on the cross-media impacts (to water and..., and submit to the Administrator the following information to show that the alternative achieves...) and their ancillary equipment during each portion of the normal dry cleaning cycle; (2) Information...

  15. 40 CFR 63.325 - Determination of equivalent emission control technology.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... other than the specific system(s) examined; and (7) Information on the cross-media impacts (to water and..., and submit to the Administrator the following information to show that the alternative achieves...) and their ancillary equipment during each portion of the normal dry cleaning cycle; (2) Information...

  16. 40 CFR 63.325 - Determination of equivalent emission control technology.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... other than the specific system(s) examined; and (7) Information on the cross-media impacts (to water and..., and submit to the Administrator the following information to show that the alternative achieves...) and their ancillary equipment during each portion of the normal dry cleaning cycle; (2) Information...

  17. 76 FR 2759 - Proposed Information Collection (VAAR Sections 809.106-1, 809.504(d), and Clause 852.209-70...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-14

    ..., or ice cream products or for laundry or dry cleaning services whether or not the firm's facility has..., Enterprise Records Service. [FR Doc. 2011-785 Filed 1-13-11; 8:45 am] BILLING CODE 8320-01-P ...

  18. 48 CFR 809.106-1 - Conditions for pre-award surveys.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... service or using service chiefs or designees appointed by the facility or VISN director will conduct a pre... for contracts covering the products and services of the following: (1) Bakeries. (2) Dairies. (3) Ice cream plants. (4) Laundry and dry cleaning activities. (b) Before any inspection, the contracting...

  19. 29 CFR 4.133 - Beneficiary of contract services.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... service and laundry and dry cleaning service for personnel at military installations. Furthermore, there... 29 Labor 1 2010-07-01 2010-07-01 true Beneficiary of contract services. 4.133 Section 4.133 Labor Office of the Secretary of Labor LABOR STANDARDS FOR FEDERAL SERVICE CONTRACTS Application of the...

  20. 76 FR 3879 - Procurement List Proposed Additions and Deletions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-21

    ... W6BB ACA White Sands Missile Range, NM. Service Type/Location: Laundry & Dry Cleaning Service, F.E... Activity: GSA/FAS Southwest Supply Center (QSDAC), Fort Worth, TX. Service Service Type/Location: Laundry... proposing to add services to the Procurement List that will be provided by nonprofit agencies employing...

  1. 48 CFR 809.106-1 - Conditions for pre-award surveys.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... for contracts covering the products and services of the following: (1) Bakeries. (2) Dairies. (3) Ice cream plants. (4) Laundry and dry cleaning activities. (b) Before any inspection, the contracting... open market purchase of fresh bakery products (such as pies, cakes, and cookies), VA will inspect and...

  2. 48 CFR 809.106-1 - Conditions for pre-award surveys.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... for contracts covering the products and services of the following: (1) Bakeries. (2) Dairies. (3) Ice cream plants. (4) Laundry and dry cleaning activities. (b) Before any inspection, the contracting... open market purchase of fresh bakery products (such as pies, cakes, and cookies), VA will inspect and...

  3. 48 CFR 809.106-1 - Conditions for pre-award surveys.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... for contracts covering the products and services of the following: (1) Bakeries. (2) Dairies. (3) Ice cream plants. (4) Laundry and dry cleaning activities. (b) Before any inspection, the contracting... open market purchase of fresh bakery products (such as pies, cakes, and cookies), VA will inspect and...

  4. 48 CFR 809.106-1 - Conditions for pre-award surveys.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... for contracts covering the products and services of the following: (1) Bakeries. (2) Dairies. (3) Ice cream plants. (4) Laundry and dry cleaning activities. (b) Before any inspection, the contracting... open market purchase of fresh bakery products (such as pies, cakes, and cookies), VA will inspect and...

  5. EVALUATION OF GEOPHYSICAL METHODS FOR THE DETECTION OF SUBSURFACE TETRACHLOROETHYLENE (PCE) IN CONTROLLED SPILL EXPERIMENTS

    EPA Science Inventory

    Tetrachloroethylene (PCE), typically used as a dry cleaning solvent, is a predominant contaminant in the subsurface at Superfund Sites. PCE is a dense non-aqueous phase liquid (DNAPL) that migrates downward into the earth, leaving behind areas of residual saturation and free prod...

  6. FIELD MEASUREMENT OF VAPOR INTRUSION RATES AT A PCE SITE (ABSTRACT ONLY)

    EPA Science Inventory

    A field study was performed to evaluate vapor intrusion (VI) of tetrachloroethylene (PCE) and other chlorinated solvents at a commercial retail site in Dallas, TX. The building is approximately 40 years old and once housed a dry cleaning operation. Results from an initial site ch...

  7. CHLORINATED SOLVENT IMPACT AND REMEDIATION STRATEGIES FOR THE DRY CLEANING INDUSTRY

    EPA Science Inventory

    Additional funding has been received from the Advanced Technologies Program of the State of Texas by collaborators on this project, Dr. Herb Ward and Dr. Joseph Hughes. This follow-up study will provide a further in depth analysis of the benefits of bioremediation for...

  8. 9 CFR 590.520 - Breaking room facilities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Breaking room facilities. 590.520 Section 590.520 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE..., clean towels or other facilities for drying hands, odorless soap, and containers for used towels. Hand...

  9. ENVIRONMENTAL TECHNOLOGY INITIATIVE: CHEMICAL-FREE CLEANING OF SEMICONDUCTORS BY THE RADIANCE PROCESS

    EPA Science Inventory

    The Radiance Process is a patented dry process for removing contaminants from surfaces. It uses light, usually from a pulsed laser and a gas inert to the surface, to entrain released contaminants. The focus of this effort is to assess the applicability of the Radiance Process t...

  10. 78 FR 65637 - Sierrita Gas Pipeline LLC; Notice of Availability of the Draft Environmental Impact Statement for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-01

    ... miles of 36-inch-diameter natural gas pipeline in Pima County, Arizona; two meter stations; two pig launchers and two pig receivers; \\1\\ and \\1\\ A pig is an internal tool that can be used to clean and dry a...

  11. Cleaning of parts for new manufacturing and parts rebuilding

    NASA Astrophysics Data System (ADS)

    Doherty, Jeff

    1994-06-01

    Parts cleaning is the largest single expense, and the most time consuming activity, in rebuilding and new manufacturing. On average, 25% to 40% of the total labor and overhead burden is spent on cleaning. EPA and OSHA pressures add to the burden by making some methods and chemicals obsolete. Some of the processes and chemicals in current use will be curtailed and or outlawed in the future. How can a shops and industries make long term decisions or capital investments in cleaning and process improvements when the government keeps changing its rules? At the MART Corporation in Saint Louis, Missouri, we manufacture a line of cabinet-style batch cleaning machines known as Power Washers. Twenty years ago MART invented and patented the Power Washer process, a cleaning method that recycles wash solution and blasts contaminates as they are washed off the more heavily contaminated parts. Since the initial invention MART has continued to R&D the washing process and develop ancillary systems that comply with EPA and OSHA regulations. For applications involving new industrial parts or items requiring specification cleaned surfaces. MART provides filtration and solution conditioning systems, part drying operations, and triple rinsing. Units are available in stainless steel or higher alloys. We are not alone in the washer manufacturing business. You have many choices of cleaning solutions (no pun intended) which will perform in your operations and yield good results. As a manufacturer, we are interested in your success with our equipment. We have all heard the horror stories of companies having selected inappropriate cleaning systems and or processes which then brought the company to its knees, production wise. Assembly, appearance, warranty, and performance shortcomings of finished products can often be directly related to the cleaning process and its shortcomings.

  12. /ital In/ /ital situ/ dc oxygen-discharge cleaning system for optical elements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koide, T.; Shidara, T.; Tanaka, K.

    1989-07-01

    /ital In/ /ital situ/ dc oxygen-discharge cleaning arrangements have been developed at the Photon Factory for the removal of carbon contamination from optical surfaces. A high cleaning rate could be achieved by producing an oxygen plasma close to the optical elements with special care taken to avoid any harmful effects from the discharge; contaminant carbon was completely removed within a few hours, at most. This short exposure time and the use of dry oxygen gas resulted in a restoration of the original ultrahigh vacuum without a bakeout. Results with a Seya-Namioka beamline for gas-phase experiments showed a flux enhancement amountingmore » to a factor of 50, and results with a grasshopper beamline showed a nearly complete recovery of the light intensity, even at the carbon /ital K/ edge.« less

  13. Aerosol chemical composition and light scattering during a winter season in Beijing

    NASA Astrophysics Data System (ADS)

    Tao, Jun; Zhang, Leiming; Gao, Jian; Wang, Han; Chai, Faihe; Wang, Shulan

    2015-06-01

    To evaluate PM2.5 contributions to light scattering under different air pollution levels, PM2.5 and its major chemical components, PM10, size-segregated water-soluble ions, and aerosol scattering coefficient (bsp) under dry conditions were measured at an urban site in Beijing in January 2013 when heavy pollution events frequently occurred. Measurements were categorized into three pollution levels including heavy-polluted (Air Quality Index (AQI) ≥ 200), light-polluted (200 > AQI ≥ 100) and clean periods (AQI < 100). The average PM2.5 mass concentration was 248 μg m-3 during the heavy-polluted period, which was 2.4 and 5.6 times of those during the light-polluted (104 μg m-3) and clean (44 μg m-3) periods, respectively. The concentrations of SO42-, NO3- and NH4+ increased much more than those of OC and EC during the heavy-polluted period compared with those during the light-polluted and clean periods. Good correlations between PM2.5 and bsp were found (R2 > 0.95) during the different pollution levels. The mass scattering efficiency (MSE) of PM2.5 was 4.9 m2 g-1 during the heavy-polluted period, which was higher than those during the light-polluted (4.3 m2 g-1) and clean periods (3.6 m2 g-1). To further evaluate the impact of individual chemical components of PM2.5 on light scattering, a multiple linear regression equation of measured bsp against the mass concentration of (NH4)2SO4, NH4NO3, Organic Matter (OM), EC, Fine Soil (FS), Coarse Matter (CM) and Other chemical compounds were performed. (NH4)2SO4, NH4NO3 and OM were the dominant species contributing to bsp under both dry and ambient conditions. OM contributed more to bsp than the sum of (NH4)2SO4 and NH4NO3 did under the dry condition during all the pollution periods and this was also the case under the ambient condition during the light-polluted and clean periods. However, the total contributions of (NH4)2SO4 and NH4NO3 to bsp under the ambient condition was 55%, much more than the 29% contribution from OM during the heavy-polluted period. High (NH4)2SO4 and NH4NO3 concentrations and their hygroscopicity were the main reasons causing visibility degradation during the heavy-polluted period, and the effect can be enhanced under high RH conditions.

  14. The effects of short pulse laser surface cleaning on porosity formation and reduction in laser welding of aluminium alloy for automotive component manufacture

    NASA Astrophysics Data System (ADS)

    AlShaer, A. W.; Li, L.; Mistry, A.

    2014-12-01

    Laser welding of aluminium alloys typically results in porosity in the fusion zones, leading to poor mechanical and corrosion performances. Mechanical and chemical cleaning of surfaces has been used previously to remove contaminants for weld joint preparations. However, these methods are slow, ineffective (e.g. due to hydrogen trapping) or lead to environmental hazards. This paper reports the effects of short pulsed laser surface cleaning on porosity formation and reduction in laser welding of AC-170PX (AA6014) aluminium sheets (coated with Ti/Zr and lubricated using a dry lubricant AlO70) with two types of joints: fillet edge and flange couch, using an AA4043 filler wire for automotive component assembly. The effect of laser cleaning on porosity reduction during laser welding using a filler wire has not been reported before. In this work, porosity and weld fusion zone geometry were examined prior to and after laser cleaning. The nanosecond pulsed Nd:YAG laser cleaning was found to reduce porosity significantly in the weld fusion zones. For the fillet edge welds, porosity was reduced to less than 0.5% compared with 10-80% without laser cleaning. For flange couch welds, porosity was reduced to 0.23-0.8% with laser cleaning from 0.7% to 4.3% without laser cleaning. This has been found to be due to the elimination of contaminations and oxide layers that contribute to the porosity formation. The laser cleaning is based on thermal ablation. This research focuses on porosity reduction in laser welding of aluminium alloy. Weld quality was investigated for two joints, fillet edge and flange couch joints. The effect of laser cleaning on porosity reduction after welding was investigated. It was found that laser cleaning reduced porosity less than 1% in both joints. Weld dimensions and strength were evaluated and discussed for both types of joints.

  15. Efficacy of low-pressure foam cleaning compared to conventional cleaning methods in the removal of bacteria from surfaces associated with convenience food.

    PubMed

    Lambrechts, A A; Human, I S; Doughari, J H; Lues, J F R

    2014-09-01

    Food borne illnesses and food poisoning are cause for concern globally. The diseases are often caused by food contamination with pathogenic bacteria due largely to poor sanitary habits or storage conditions. Prevalence of some bacteria on cleaned and sanitised food contact surfaces from eight convenience food plants in Gauteng (South Africa) was investigated with the view to evaluate the efficacy of the cleaning methods used with such food contact surfaces. The microbial load of eight convenience food manufacturing plants was determined by sampling stainless steel food contact surfaces after they had been cleaned and sanitised at the end of a day's shift. Samples were analysed for Total Plate Count (TPC), Escherichia coli, Salmonella species, Staphylococcus aureus and Listeria species. Results showed that 59 % of the total areas sampled for TPC failed to comply with the legal requirements for surfaces, according to the Foodstuffs, Cosmetics and Disinfectants Act (< 100 cfu.cm(-2)). S. aureus and Salmonella were not detected, but Listeria was detected in 23 % and E. coli in 1.3 % of the samples. Fifty percent (50 %) of the plants applied conventional cleaning methods for cleaning and sanitation and 50 % used the low-pressure foam (LPF) method. There was significant difference (P ≤ 0.05) between the mean TPC values of the conventional cleaning method (14 358.82) compared to that of LPF method (2 386.51) but no significant difference (P > 0.05) in terms of Listeria species isolates obtained from both cleaning methods. The LPF method proved to be the superior cleaning option for lowering TPC counts. Regardless of cleaning method used, pathogens continued to flourish on various surfaces, including dry stainless steel, posing a contamination hazard for a considerable period depending on the contamination level and type of pathogen. Intensive training for proper chemical usage and strict procedural compliance among workers for efficient cleaning procedures is recommended.

  16. The commercial clothes dryer market: Market structure and opportunities for microwave dryers. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leon, G.; McNulty, S.

    1995-08-01

    EPRI`s prototype commercial microwave clothes dryer offers significant benefits over conventional dryers, including faster drying at lower temperatures, less damage to fabrics, and possible drying of some dry-clean-only fabrics. With the technical challenges overcome, EPRI sponsored the microwave dryer project to gauge the likely market response to this new drying technology and to determine the best marketing approach for commercial microwave dryers. This market assessment provides information about the dryer features required in various commercial market segments as well as guidance in choosing the segments and subsegments most likely to accept microwave clothes dryers. At present, the market segments mostmore » amenable to microwave dryer technology include the coin-operated, medium, and large dryer owners. Promising subsegments include the apartment coin-operated market and businesses that have capacity constraints, low fuel cost sensitivity, or extremely low dryer usage.« less

  17. SiC/GaN Based Optically Triggered MESFET for High Power Efficiency and High Radiation Resistance Solid State Switch Application for Actuator System

    DTIC Science & Technology

    2016-06-23

    somnath.chattopadhyay@csun.edu 1-818-677-7197 clean/etch. Excessively hard- baked photoresist can usually be dissolved in piranha etching solution. 48 hours of...coated onto the freshly cleaned and dried wafer at 3000RPM, then soft- baked at 180ºC for 120 seconds. This gives a PMGI layer of about 0.4µm. Then the...PR is spin coated onto the wafer at about 4000RPM and soft baked at 115ºC for 90seconds, resulting in a PR layer about 1.3µm thick. The wafer is

  18. [Thermal energy utilization analysis and energy conservation measures of fluidized bed dryer].

    PubMed

    Xing, Liming; Zhao, Zhengsheng

    2012-07-01

    To propose measures for enhancing thermal energy utilization by analyzing drying process and operation principle of fluidized bed dryers,in order to guide optimization and upgrade of fluidized bed drying equipment. Through a systematic analysis on drying process and operation principle of fluidized beds,the energy conservation law was adopted to calculate thermal energy of dryers. The thermal energy of fluidized bed dryers is mainly used to make up for thermal consumption of water evaporation (Qw), hot air from outlet equipment (Qe), thermal consumption for heating and drying wet materials (Qm) and heat dissipation to surroundings through hot air pipelines and cyclone separators. Effective measures and major approaches to enhance thermal energy utilization of fluidized bed dryers were to reduce exhaust gas out by the loss of heat Qe, recycle dryer export air quantity of heat, preserve heat for dry towers, hot air pipes and cyclone separators, dehumidify clean air in inlets and reasonably control drying time and air temperature. Such technical parameters such air supply rate, air inlet temperature and humidity, material temperature and outlet temperature and humidity are set and controlled to effectively save energy during the drying process and reduce the production cost.

  19. Target Organ Metabolism, Toxicity, and Mechanisms of Trichloroethylene and Perchloroethylene: Key Similarities, Differences, and Data Gaps.

    PubMed

    Cichocki, Joseph A; Guyton, Kathryn Z; Guha, Neela; Chiu, Weihsueh A; Rusyn, Ivan; Lash, Lawrence H

    2016-10-01

    Trichloroethylene (TCE) and perchloroethylene or tetrachloroethylene (PCE) are high-production volume chemicals with numerous industrial applications. As a consequence of their widespread use, these chemicals are ubiquitous environmental contaminants to which the general population is commonly exposed. It is widely assumed that TCE and PCE are toxicologically similar; both are simple olefins with three (TCE) or four (PCE) chlorines. Nonetheless, despite decades of research on the adverse health effects of TCE or PCE, few studies have directly compared these two toxicants. Although the metabolic pathways are qualitatively similar, quantitative differences in the flux and yield of metabolites exist. Recent human health assessments have uncovered some overlap in target organs that are affected by exposure to TCE or PCE, and divergent species- and sex-specificity with regard to cancer and noncancer hazards. The objective of this minireview is to highlight key similarities, differences, and data gaps in target organ metabolism and mechanism of toxicity. The main anticipated outcome of this review is to encourage research to 1) directly compare the responses to TCE and PCE using more sensitive biochemical techniques and robust statistical comparisons; 2) more closely examine interindividual variability in the relationship between toxicokinetics and toxicodynamics for TCE and PCE; 3) elucidate the effect of coexposure to these two toxicants; and 4) explore new mechanisms for target organ toxicity associated with TCE and/or PCE exposure. Copyright © 2016 by The American Society for Pharmacology and Experimental Therapeutics.

  20. Understanding pH Effects on Trichloroethylene and Perchloroethylene Adsorption to Iron in Permeable Reactive Barriers for Groundwater Remediation.

    PubMed

    Luo, Jing; Farrell, James

    2013-01-01

    Metallic iron filings are becoming increasing used in permeable reactive barriers for remediating groundwater contaminated by chlorinated solvents. Understanding solution pH effects on rates of reductive dechlorination in permeable reactive barriers is essential for designing remediation systems that can meet treatment objectives under conditions of varying groundwater properties. The objective of this research was to investigate how the solution pH value affects adsorption of trichloroethylene (TCE) and perchloroethylene (PCE) on metallic iron surfaces. Because adsorption is first required before reductive dechlorination can occur, pH effects on halocarbon adsorption energies may explain pH effects on dechlorination rates. Adsorption energies for TCE and PCE were calculated via molecular mechanics simulations using the Universal force field and a self-consistent reaction field charge equilibration scheme. A range in solution pH values was simulated by varying the amount of atomic hydrogen adsorbed on the iron. The potential energies associated TCE and PCE complexes were dominated by electrostatic interactions, and complex formation with the surface was found to result in significant electron transfer from the iron to the adsorbed halocarbons. Adsorbed atomic hydrogen was found to lower the energies of TCE complexes more than those for PCE. Attractions between atomic hydrogen and iron atoms were more favorable when TCE versus PCE was adsorbed to the iron surface. These two findings are consistent with the experimental observation that changes in solution pH affect TCE reaction rates more than those for PCE.

  1. Plasma cleaning of nanoparticles from EUV mask materials by electrostatics

    NASA Astrophysics Data System (ADS)

    Lytle, W. M.; Raju, R.; Shin, H.; Das, C.; Neumann, M. J.; Ruzic, D. N.

    2008-03-01

    Particle contamination on surfaces used in extreme ultraviolet (EUV) mask blank deposition, mask fabrication, and patterned mask handling must be avoided since the contamination can create significant distortions and loss of reflectivity. Particles on the order of 10nm are problematic during MLM mirror fabrication, since the introduced defects disrupt the local Bragg planes. The most serious problem is the accumulation of particles on surfaces of patterned blanks during EUV light exposure, since > 25nm particles will be printed without an out-of-focus pellicle. Particle contaminants are also a problem with direct imprint processes since defects are printed every time. Plasma Assisted Cleaning by Electrostatics (PACE) works by utilizing a helicon plasma as well as a pulsed DC substrate bias to charge particle and repel them electrostatically from the surface. Removal of this nature is a dry cleaning method and removes contamination perpendicular from the surface instead of rolling or sweeping the particles off the surface, a benefit when cleaning patterned surfaces where contamination can be rolled or trapped between features. Also, an entire mask can be cleaned at once since the plasma can cover the entire surface, thus there is no need to focus in on an area to clean. Sophisticated particle contamination detection system utilizing high power laser called DEFCON is developed to analyze the particle removal after PACE cleaning process. PACE has shown greater than 90 % particle removal efficiencies for 30 to 220 nm PSL particles on ruthenium capped quartz. Removal results for silicon surfaces and quartz surfaces show similar removal efficiencies. Results of cleaning 80 nm PSL spheres from silicon substrates will be shown.

  2. Stool Test: C. Difficile Toxin (For Parents)

    MedlinePlus

    ... sealable container before taking it to the lab. Plastic wrap also can be used to line the diaper of an infant or toddler who isn't yet using the toilet. The wrap should be placed so that urine ... be collected into a clean, dry plastic jar with a screw-cap lid. For best ...

  3. In-Situ Bioremediation of Solvent Saturated Soils Using Methane, Propane, and Butane-Oxidizers

    DTIC Science & Technology

    2000-02-02

    used as a degreasing agent, dry cleaning agent and solvent in various industries. It also can be found in household products such as spot cleaner...solvent widely used in various industries and can be found in many household products . 1,1,1-TCA is considered relatively highly soluble, therefore

  4. How to Guarantee Long Life for your Carpeting.

    ERIC Educational Resources Information Center

    Gilliland, John W.

    1968-01-01

    Carpeting must be maintained through a proper maintenance program so as to extend the carpet's life and allow for continued sound control. Four types of common soils or stains are discussed--(1) dry soils, (2) water soluble stains, (3) petroleum soluble stains, and (4) other stains. Various cleaning methods, such as, vacuuming, spot removal, wet…

  5. 16 CFR 1611.35 - Testing certain classes of fabric and film.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 16 Commercial Practices 2 2012-01-01 2012-01-01 false Testing certain classes of fabric and film... REGULATIONS STANDARD FOR THE FLAMMABILITY OF VINYL PLASTIC FILM Rules and Regulations § 1611.35 Testing certain classes of fabric and film. (a) Fabric not customarily washed or dry cleaned. (1) Except as...

  6. 16 CFR 1611.35 - Testing certain classes of fabric and film.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 16 Commercial Practices 2 2014-01-01 2014-01-01 false Testing certain classes of fabric and film... REGULATIONS STANDARD FOR THE FLAMMABILITY OF VINYL PLASTIC FILM Rules and Regulations § 1611.35 Testing certain classes of fabric and film. (a) Fabric not customarily washed or dry cleaned. (1) Except as...

  7. 16 CFR 1611.35 - Testing certain classes of fabric and film.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Testing certain classes of fabric and film... REGULATIONS STANDARD FOR THE FLAMMABILITY OF VINYL PLASTIC FILM Rules and Regulations § 1611.35 Testing certain classes of fabric and film. (a) Fabric not customarily washed or dry cleaned. (1) Except as...

  8. 9 CFR 381.305 - Equipment and procedures for heat processing systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... control unit. A nonreturn valve shall be provided in the air supply line to prevent water from entering... control unit. A nonreturn valve shall be provided in the air supply line to prevent water from entering... supply of clean, dry air. The recorder timing mechanism shall be accurate. (i) Chart-type devices...

  9. 7 CFR 58.412 - Coolers or curing rooms.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 3 2012-01-01 2012-01-01 false Coolers or curing rooms. 58.412 Section 58.412....412 Coolers or curing rooms. Coolers or curing rooms where cheese is held for curing or storage shall... times. The shelves shall be kept clean and dry. This does not preclude the maintenance of suitable...

  10. 7 CFR 58.412 - Coolers or curing rooms.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 3 2014-01-01 2014-01-01 false Coolers or curing rooms. 58.412 Section 58.412....412 Coolers or curing rooms. Coolers or curing rooms where cheese is held for curing or storage shall... times. The shelves shall be kept clean and dry. This does not preclude the maintenance of suitable...

  11. 7 CFR 58.412 - Coolers or curing rooms.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 3 2013-01-01 2013-01-01 false Coolers or curing rooms. 58.412 Section 58.412....412 Coolers or curing rooms. Coolers or curing rooms where cheese is held for curing or storage shall... times. The shelves shall be kept clean and dry. This does not preclude the maintenance of suitable...

  12. 7 CFR 58.412 - Coolers or curing rooms.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Coolers or curing rooms. 58.412 Section 58.412....412 Coolers or curing rooms. Coolers or curing rooms where cheese is held for curing or storage shall... times. The shelves shall be kept clean and dry. This does not preclude the maintenance of suitable...

  13. 7 CFR 58.412 - Coolers or curing rooms.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Coolers or curing rooms. 58.412 Section 58.412....412 Coolers or curing rooms. Coolers or curing rooms where cheese is held for curing or storage shall... times. The shelves shall be kept clean and dry. This does not preclude the maintenance of suitable...

  14. 40 CFR 53.61 - Test conditions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Test conditions. 53.61 Section 53.61... Equivalent Methods for PM2.5 § 53.61 Test conditions. (a) Sampler surface preparation. Internal surfaces of the candidate sampler shall be cleaned and dried prior to performing any Class II sampler test in this...

  15. 40 CFR 53.61 - Test conditions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 5 2011-07-01 2011-07-01 false Test conditions. 53.61 Section 53.61... Equivalent Methods for PM2.5 § 53.61 Test conditions. (a) Sampler surface preparation. Internal surfaces of the candidate sampler shall be cleaned and dried prior to performing any Class II sampler test in this...

  16. 16 CFR 1611.35 - Testing certain classes of fabric and film.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Testing certain classes of fabric and film... REGULATIONS STANDARD FOR THE FLAMMABILITY OF VINYL PLASTIC FILM Rules and Regulations § 1611.35 Testing certain classes of fabric and film. (a) Fabric not customarily washed or dry cleaned. (1) Except as...

  17. Evaluation of a commercial air filter for removal of viruses from the air.

    PubMed

    Roelants, P; Boon, B; Lhoest, W

    1968-10-01

    The effectiveness of a commercial absolute air filter for removal of viruses from air was tested with an actinophage, under the usual conditions of a laminar airflow clean room. A new method of dry phage dispersion is described. The filter showed an average reduction of 99.996% of airborne actinophage.

  18. IN-SITU DUOX™ CHEMICAL OXIDATION TECHNOLOGY TO TREAT CHLORINATED ORGANICS AT THE ROOSEVELT MILLS SITE, VERNON, CT: SITE CHARACTERIZATION AND TREATABILITY STUDY

    EPA Science Inventory

    A study was performed investigating the feasibility of applying the DUOX™ chemical oxidation technology to chlorinated solvent contaminated media at the Roosevelt Mills site in Vernon, Connecticut. The Roosevelt Mills site is a former woolen mill that included dry cleaning operat...

  19. 40 CFR 52.246 - Control of dry cleaning solvent vapor losses.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Joaquin Valley Intrastate Air Quality Control Regions (the “Regions”), as described in 40 CFR part 81, dated July 1, 1979, except as follows: (1) In the following portions of the Sacramento Valley Region... Basin portion). (iii) Yuba County APCD. (iv) Sutter County APCD. (2) In the following portions of the...

  20. 40 CFR 52.246 - Control of dry cleaning solvent vapor losses.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Joaquin Valley Intrastate Air Quality Control Regions (the “Regions”), as described in 40 CFR part 81, dated July 1, 1979, except as follows: (1) In the following portions of the Sacramento Valley Region... Basin portion). (iii) Yuba County APCD. (iv) Sutter County APCD. (2) In the following portions of the...

  1. 40 CFR 52.246 - Control of dry cleaning solvent vapor losses.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Joaquin Valley Intrastate Air Quality Control Regions (the “Regions”), as described in 40 CFR part 81, dated July 1, 1979, except as follows: (1) In the following portions of the Sacramento Valley Region... Basin portion). (iii) Yuba County APCD. (iv) Sutter County APCD. (2) In the following portions of the...

  2. 40 CFR 52.246 - Control of dry cleaning solvent vapor losses.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Joaquin Valley Intrastate Air Quality Control Regions (the “Regions”), as described in 40 CFR part 81, dated July 1, 1979, except as follows: (1) In the following portions of the Sacramento Valley Region... Basin portion). (iii) Yuba County APCD. (iv) Sutter County APCD. (2) In the following portions of the...

  3. ENVIRONMENTAL TECHNOLOGY VERIFICATON: TEST REPORT OF CONTROL OF BIOAEROSOLS IN HVAC SYSTEMS AAF INTERNATIONAL DRIPAK 90/95%

    EPA Science Inventory

    The Environmental Technology Verification report discusses the technology and performance of the DriPak 90/95% air filter for dust and bioaerosol filtration manufactured by AAF International. The pressure drop across the filter was 104 Pa clean and 348 Pa dust loaded, and the fil...

  4. 45 CFR 674.5 - Requirements for collection, handling, documentation, and curation of Antarctic meteorites.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...; and (v) Thawing in a clean, dry, non-reactive gas environment, such as nitrogen or argon. (2) Sample..., documentation, and curation of Antarctic meteorites. 674.5 Section 674.5 Public Welfare Regulations Relating to Public Welfare (Continued) NATIONAL SCIENCE FOUNDATION ANTARCTIC METEORITES § 674.5 Requirements for...

  5. 45 CFR 674.5 - Requirements for collection, handling, documentation, and curation of Antarctic meteorites.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...; and (v) Thawing in a clean, dry, non-reactive gas environment, such as nitrogen or argon. (2) Sample..., documentation, and curation of Antarctic meteorites. 674.5 Section 674.5 Public Welfare Regulations Relating to Public Welfare (Continued) NATIONAL SCIENCE FOUNDATION ANTARCTIC METEORITES § 674.5 Requirements for...

  6. 45 CFR 674.5 - Requirements for collection, handling, documentation, and curation of Antarctic meteorites.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...; and (v) Thawing in a clean, dry, non-reactive gas environment, such as nitrogen or argon. (2) Sample..., documentation, and curation of Antarctic meteorites. 674.5 Section 674.5 Public Welfare Regulations Relating to Public Welfare (Continued) NATIONAL SCIENCE FOUNDATION ANTARCTIC METEORITES § 674.5 Requirements for...

  7. 45 CFR 674.5 - Requirements for collection, handling, documentation, and curation of Antarctic meteorites.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...; and (v) Thawing in a clean, dry, non-reactive gas environment, such as nitrogen or argon. (2) Sample..., documentation, and curation of Antarctic meteorites. 674.5 Section 674.5 Public Welfare Regulations Relating to Public Welfare (Continued) NATIONAL SCIENCE FOUNDATION ANTARCTIC METEORITES § 674.5 Requirements for...

  8. 7 CFR 800.75 - Kinds of official inspection and weighing services.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... carrier or container is clean; dry; free of infestation, rodents, toxic substances, and foreign odor; and... containers loaded aboard a carrier; and (3) if practicable, sealing the carrier for security. (k) Test weight... Report of Test. (l) Railroad track scale testing service. This service consists of official personnel (1...

  9. 7 CFR 800.75 - Kinds of official inspection and weighing services.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... carrier or container is clean; dry; free of infestation, rodents, toxic substances, and foreign odor; and... containers loaded aboard a carrier; and (3) if practicable, sealing the carrier for security. (k) Test weight... Report of Test. (l) Railroad track scale testing service. This service consists of official personnel (1...

  10. 7 CFR 800.75 - Kinds of official inspection and weighing services.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... carrier or container is clean; dry; free of infestation, rodents, toxic substances, and foreign odor; and... containers loaded aboard a carrier; and (3) if practicable, sealing the carrier for security. (k) Test weight... Report of Test. (l) Railroad track scale testing service. This service consists of official personnel (1...

  11. 7 CFR 800.75 - Kinds of official inspection and weighing services.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... carrier or container is clean; dry; free of infestation, rodents, toxic substances, and foreign odor; and... containers loaded aboard a carrier; and (3) if practicable, sealing the carrier for security. (k) Test weight... Report of Test. (l) Railroad track scale testing service. This service consists of official personnel (1...

  12. 7 CFR 800.75 - Kinds of official inspection and weighing services.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... carrier or container is clean; dry; free of infestation, rodents, toxic substances, and foreign odor; and... containers loaded aboard a carrier; and (3) if practicable, sealing the carrier for security. (k) Test weight... Report of Test. (l) Railroad track scale testing service. This service consists of official personnel (1...

  13. 46 CFR 160.151-45 - Equipment required for servicing facilities.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... and bulletins in effect as indicated on the annual list issued in accordance with § 160.151-35(b)(2...) A source of clean, dry, pressurized air; hoses; and attachments for inflating liferafts; (h) A..., except for items of equipment that are readily available; (p) A means for load-testing davit-launched...

  14. 77 FR 809 - Notice of Lodging of a Consent Decree Under the Clean Water Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-06

    ... terms and conditions of National Pollution Discharge Elimination System permits that Indiana issued to...,'' during wet weather events, and some dry weather time periods, into ``waters of the United States'' and ``waters of the state.'' The proposed Consent Decree would require South Bend to reduce its combined sewer...

  15. 76 FR 56223 - Notice of Lodging of a Consent Decree Under the Clean Water Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-12

    ... terms and conditions of National Pollution Discharge Elimination System permits that Indiana issued to... wet weather events, and some dry weather time periods, into ``waters of the United States'' and ``waters of the state.'' The proposed Consent Decree would require Elkhart to reduce its combined sewer...

  16. 30 CFR 35.20 - Autogenous-ignition temperature test.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... timer shall be stopped. The test flask shall then be flushed well with clean dry air and, after a lapse... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Autogenous-ignition temperature test. 35.20..., EVALUATION, AND APPROVAL OF MINING PRODUCTS FIRE-RESISTANT HYDRAULIC FLUIDS Test Requirements § 35.20...

  17. 48 CFR 237.7101 - Solicitation provisions and contract clauses.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... and dry cleaning services to be provided on a bulk weight basis. (1) Insert a reasonable per pound..., Instruction to Offerors (Bulk Weight), in solicitations for laundry services to be provided on a bulk weight... laundry services on a bag type basis, insert reasonable per pound prices by bag type. (2) Insert an...

  18. Effects of dust accumulation and module cleaning on performance ratio of solar rooftop system and solar power plants

    NASA Astrophysics Data System (ADS)

    Sakarapunthip, Nattakarn; Chenvidhya, Dhirayut; Chuangchote, Surawut; Kirtikara, Krissanapong; Chenvidhya, Tanokkorn; Onreabroy, Wandee

    2017-08-01

    Thailand is an agricultural country, with rice, sugar, and cassava as the major export products. Production of rice, sugar cane, and cassava entails agricultural activities that give rise to significant airborne dusts. In this work, five photovoltaic (PV) units (one solar rooftop and four power plants) are selected for the study. From the study of dust accumulation on glass surface located near rice farms, it was found that opaque areas due to the deposition of dust are 11-14% after 1-2-week exposure. As a consequence, PV system performance is affected. Performance ratio was calculated to determine these effects. Overall results reveal that during the dry and hot seasons, dust deposition significantly affects the performance ratio. The performance ratio reduces by 1.6-3% for 1-month dust accumulation and reduces by 6-8% for 2-month dust accumulation. After cleaning the dust accumulated, the performance ratio greatly increases, resulting in the increase in the energy output by 10%. This increase provides economic and cost benefits of PV cleaning. The performance ratio is not significantly changed during the rainy season, which PV modules are relatively clean as the dust is washed away by rain. It was also found that most of the solar power plants in Thailand still rely on manual cleaning of PV modules with washing water followed by wiping. However, only one power plant, employs a machine for cleaning, resulting in lower cleaning costs.

  19. Cheap non-toxic non-corrosive method of glass cleaning evaluated by contact angle, AFM, and SEM-EDX measurements.

    PubMed

    Dey, Tania; Naughton, Daragh

    2017-05-01

    Glass surface cleaning is the very first step in advanced coating deposition and it also finds use in conserving museum objects. However, most of the wet chemical methods of glass cleaning use toxic and corrosive chemicals like concentrated sulfuric acid (H 2 SO 4 ), piranha (a mixture of concentrated sulfuric acid and 30% hydrogen peroxide), and hydrogen fluoride (HF). On the other hand, most of the dry cleaning techniques like UV-ozone, plasma, and laser treatment require costly instruments. In this report, five eco-friendly wet chemical methods of glass cleaning were evaluated in terms of contact angle (measured by optical tensiometer), nano-scale surface roughness (measured by atomic force microscopy or AFM), and elemental composition (measured by energy dispersive x-ray spectroscopy or SEM-EDX). These glass cleaning methods are devoid of harsh chemicals and costly equipment, hence can be applied in situ in close proximity with plantation such as greenhouse or upon subtle objects such as museum artifacts. Out of these five methods, three methods are based on the chemical principle of chelation. It was found that the citric acid cleaning method gave the greatest change in contact angle within the hydrophilic regime (14.25° for new glass) indicating effective cleansing and the least surface roughness (0.178 nm for new glass) indicating no corrosive effect. One of the glass sample showed unique features which were traced backed to the history of the glass usage.

  20. Issues Related to Cleaning Complex Geometry Surfaces with ODC-Free Solvents

    NASA Technical Reports Server (NTRS)

    Bradford, Blake F.; Wurth, Laura A.; Nayate, Pramod D.; McCool, Alex (Technical Monitor)

    2001-01-01

    Implementing ozone depleting chemicals (ODC)-free solvents into full-scale reusable solid rocket motor cleaning operations has presented problems due to the low vapor pressures of the solvents. Because of slow evaporation, solvent retention is a problem on porous substrates or on surfaces with irregular geometry, such as threaded boltholes, leak check ports, and nozzle backfill joints. The new solvents are being evaluated to replace 1,1,1-trichloroethane, which readily evaporates from these surfaces. Selection of the solvents to be evaluated on full-scale hardware was made based on results of subscale tests performed with flat surface coupons, which did not manifest the problem. Test efforts have been undertaken to address concerns with the slow-evaporating solvents. These concerns include effects on materials due to long-term exposure to solvent, potential migration from bolthole threads to seal surfaces, and effects on bolt loading due to solvent retention in threads. Tests performed to date have verified that retained solvent does not affect materials or hardware performance. Process modifications have also been developed to assist drying, and these can be implemented if additional drying becomes necessary.

  1. Super-hydrophobic Silver-Doped TiO2 @ Polycarbonate Coatings Created on Various Material Substrates with Visible-Light Photocatalysis for Self-Cleaning Contaminant Degradation.

    PubMed

    Li, Zhengjian; Sun, Zongzhao; Duan, Zhiqiang; Li, Rui; Yang, Yanli; Wang, Jingyi; Lv, Xiaoxia; Qi, Wei; Wang, Hua

    2017-02-20

    In the present work, a facile and efficient fabrication method has been developed for creating super-hydrophobic coatings of silver-doped TiO 2 @polycarbonate (TiO 2 (Ag)@PC) on the substrates of different materials with photocatalytic self-cleaning performances simply by the "dipping and drying" process. The substrates were first patterned with glue and then deposited with the dopamine-capped TiO 2 (Ag)@PC (DA-TiO 2 (Ag)@PC) nanocomposites, followed by the further etching with dimethylbenzene. The so prepared super-hydrophobic E-DA-TiO 2 (Ag)@PC coatings could present the lotus leaf-like porous architectures, high adhesion stability, and especially the visible-light photocatalysis for organic contaminant degradation, thus promising the wide outdoor and indoor applications like water proofing, metal erosion protection, and surface self-cleaning.

  2. Biosecurity and Vector Behaviour: Evaluating the Potential Threat Posed by Anglers and Canoeists as Pathways for the Spread of Invasive Non-Native Species and Pathogens

    PubMed Central

    Anderson, Lucy G.; White, Piran C. L.; Stebbing, Paul D.; Stentiford, Grant D.; Dunn, Alison M.

    2014-01-01

    Invasive non-native species (INNS) endanger native biodiversity and are a major economic problem. The management of pathways to prevent their introduction and establishment is a key target in the Convention on Biological Diversity's Aichi biodiversity targets for 2020. Freshwater environments are particularly susceptible to invasions as they are exposed to multiple introduction pathways, including non-native fish stocking and the release of boat ballast water. Since many freshwater INNS and aquatic pathogens can survive for several days in damp environments, there is potential for transport between water catchments on the equipment used by recreational anglers and canoeists. To quantify this biosecurity risk, we conducted an online questionnaire with 960 anglers and 599 canoeists to investigate their locations of activity, equipment used, and how frequently equipment was cleaned and/or dried after use. Anglers were also asked about their use and disposal of live bait. Our results indicate that 64% of anglers and 78.5% of canoeists use their equipment/boat in more than one catchment within a fortnight, the survival time of many of the INNS and pathogens considered in this study and that 12% of anglers and 50% of canoeists do so without either cleaning or drying their kit between uses. Furthermore, 8% of anglers and 28% of canoeists had used their equipment overseas without cleaning or drying it after each use which could facilitate both the introduction and secondary spread of INNS in the UK. Our results provide a baseline against which to evaluate the effectiveness of future biosecurity awareness campaigns, and identify groups to target with biosecurity awareness information. Our results also indicate that the biosecurity practices of these groups must improve to reduce the likelihood of inadvertently spreading INNS and pathogens through these activities. PMID:24717714

  3. Possibilities of mercury removal in the dry flue gas cleaning lines of solid waste incineration units.

    PubMed

    Svoboda, Karel; Hartman, Miloslav; Šyc, Michal; Pohořelý, Michael; Kameníková, Petra; Jeremiáš, Michal; Durda, Tomáš

    2016-01-15

    Dry methods of the flue gas cleaning (for HCl and SO2 removal) are useful particularly in smaller solid waste incineration units. The amount and forms of mercury emissions depend on waste (fuel) composition, content of mercury and chlorine and on the entire process of the flue gas cleaning. In the case of high HCl/total Hg molar ratio in the flue gas, the majority (usually 70-90%) of mercury is present in the form of HgCl2 and a smaller amount in the form of mercury vapors at higher temperatures. Removal of both main forms of mercury from the flue gas is dependent on chemical reactions and sorption processes at the temperatures below approx. 340 °C. Significant part of HgCl2 and a small part of elemental Hg vapors can be adsorbed on fly ash and solid particle in the air pollution control (APC) processes, which are removed in dust filters. Injection of non-impregnated active carbon (AC) or activated lignite coke particles is able to remove mainly the oxidized Hg(2+) compounds. Vapors of metallic Hg(o) are adsorbed relatively weakly. Much better chemisorption of Hg(o) together with higher sorbent capacity is achieved by AC-based sorbents impregnated with sulfur, alkali poly-sulfides, ferric chloride, etc. Inorganic sorbents with the same or similar chemical impregnation are also applicable for deeper Hg(o) removal (over 85%). SCR catalysts convert part of Hg(o) into oxidized compounds (HgO, HgCl2, etc.) contributing to more efficient Hg removal, but excess of NH3 has a negative effect. Both forms, elemental Hg(o) and HgCl2, can be converted into HgS particles by reacting with droplets/aerosol of poly-sulfides solutions/solids in flue gas. Mercury captured in the form of water insoluble HgS is more advantageous in the disposal of solid waste from APC processes. Four selected options of the dry flue gas cleaning with mercury removal are analyzed, assessed and compared (in terms of efficiency of Hg-emission reduction and costs) with wet methods and retrofits for more efficient Hg-removal. Overall mercury removal efficiencies from flue gas can attain 80-95%, depending on sorbent type/impregnation, sorbent surplus and operating conditions. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Dry syngas purification process for coal gas produced in oxy-fuel type integrated gasification combined cycle power generation with carbon dioxide capturing feature.

    PubMed

    Kobayashi, Makoto; Akiho, Hiroyuki

    2017-12-01

    Electricity production from coal fuel with minimizing efficiency penalty for the carbon dioxide abatement will bring us sustainable and compatible energy utilization. One of the promising options is oxy-fuel type Integrated Gasification Combined Cycle (oxy-fuel IGCC) power generation that is estimated to achieve thermal efficiency of 44% at lower heating value (LHV) base and provide compressed carbon dioxide (CO 2 ) with concentration of 93 vol%. The proper operation of the plant is established by introducing dry syngas cleaning processes to control halide and sulfur compounds satisfying tolerate contaminants level of gas turbine. To realize the dry process, the bench scale test facility was planned to demonstrate the first-ever halide and sulfur removal with fixed bed reactor using actual syngas from O 2 -CO 2 blown gasifier for the oxy-fuel IGCC power generation. Design parameter for the test facility was required for the candidate sorbents for halide removal and sulfur removal. Breakthrough test was performed on two kinds of halide sorbents at accelerated condition and on honeycomb desulfurization sorbent at varied space velocity condition. The results for the both sorbents for halide and sulfur exhibited sufficient removal within the satisfactory short depth of sorbent bed, as well as superior bed conversion of the impurity removal reaction. These performance evaluation of the candidate sorbents of halide and sulfur removal provided rational and affordable design parameters for the bench scale test facility to demonstrate the dry syngas cleaning process for oxy-fuel IGCC system as the scaled up step of process development. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Incidence of ochratoxin A in rice and dried fruits from Rabat and Salé area, Morocco.

    PubMed

    Zinedine, A; Soriano, J M; Juan, C; Mojemmi, B; Moltó, J C; Bouklouze, A; Cherrah, Y; Idrissi, L; El Aouad, R; Mañes, J

    2007-03-01

    One hundred samples of dried fruits (20 dried raisins, 20 walnuts, 20 peanuts, 20 dried figs and 20 pistachios) and 20 samples of rice purchased from retail shops in the Rabat and Salé area in Morocco were analysed for ochratoxin A (OTA) by immunoaffinity clean-up (IAC) and liquid chromatography (LC) with fluorescence detection. The limit of quantification (LOQ) (S/N = 10:1) of OTA was 0.02 ng g(-1) in rice, 0.03 ng g(-1) in pistachio, peanut and walnut, and 0.03 ng g(-1) in dried raisins and dried figs. The incidences of occurrence of OTA in dried raisins, walnuts, peanuts, dried figs and rice were 30, 35, 25, 65 and 90%, respectively. Analytical results showed that pistachio samples contained no detectable OTA, but concentrations ranged from 0.02 +/- 0.01 to 32.4 +/- 2.10 ng g(-1) in rice, from 0.10 +/- 0.05 to 2.36 +/- 0.75 in peanut, from 0.03 +/- 0.01 to 1.42 +/- 0.45 in dried figs, from 0.05 +/- 0.02 to 4.95 +/- 0.02 in dried raisins, and from 0.04 +/- 0.01 to 0.23 +/- 0.05 in walnuts. The results also showed that 15% of the total number of rice samples analysed exceeded the 2002 regulatory limit set by European Union regulations for cereals. This is the first report on the occurrence of OTA in dried fruits and rice available in Morocco.

  6. Harnessing science for environmental regulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Graham, J.D.

    1991-01-01

    An introductory chapter by Graham frames the issues to be discussed; then the following three chapters describe the formation and character of three organizations. These chapters are written by authors who have each had an active management role in the organization they are writing about: Terry F. Yosie, now at the American Petroleum Institute, who staffed the SAB (Science Advisory Board) while he was at EPA; Robert A. Neal, who headed CIIT (Chemical Industry Institute of Toxicology) before leaving for a position at Vanderbilt University; and Thomas P. Grumbly, former executive director of HEI (Health Effects Institute) now president ofmore » Clean Sites, Inc. While these chapters are well written and make a vital contribution to the overall development of the book's themes, the most valuable and enjoyable parts of the book are the succeeding five chapters, which present case studies dealing with EPA's regulatory efforts on unleaded gasoline, perchloroethylene, formaldehyde, nitrates in drinking water, and carbon monoxide. Each of these case studies, nominally historical accounts of how one or more of these (three) organizations participated in the regulatory controversy, offer insight into the broader issues of dealing with, and incorporating into regulations scientific information that has high uncertainty. One of the richest aspects of the five case studies is the extensive use of referenced interviews with identified participants from all aspects of the regulatory process. This material illuminates the motivation, emotions, and goals of the different players, helping the reader to understand their positions and other issues, such as why industry pursues, and EPA and the environmental movement appear to resist, good science; what underlies EPA's preferences for one regulatory option over another; and why scientists are histant to give yes-or-no answers in accord with the real time needs of the regulatory agency.« less

  7. FIELD DEMONSTRATION OF PERVAPORATION FOR THE SEPARATION OF VOLATILE ORGANIC COMPOUNDS FROM A SURFACTANT-BASED SOIL REMEDIATION FLUID

    EPA Science Inventory

    As part of a Department of Defense project, the US Environmental Protection Agency was responsible for designing, building and field operating a pilot-scale pervaporation unit. The field site ws an active dry cleaning facility on the grounds of Marine Corps Base Camp Lejeune in J...

  8. Measurements of Atmospheric NH3, NOy/NOx, and NO2 and Deposition of Total Nitrogen at the Beaufort, NC CASTNET Site (BFT142)

    EPA Science Inventory

    The Clean Air Status and Trends Network (CASTNET) is a long-term environmental monitoring program that measures trends in ambient air quality and atmospheric dry pollutant deposition across the United States. CASTNET has been operating since 1987 and currently consists of 89 moni...

  9. BIOMASS-FUELED, SMALL-SCALE, INTEGRATED-GASIFIER, GAS-TURBINE POWER PLANT: PROGRESS REPORT ON THE PHASE 2 DEVELOPMENT

    EPA Science Inventory

    The paper reports the latest efforts to complete development of Phase 2 of a three-phase effort to develop a family of small-scale (1 to 20 MWe) biomass-fueled power plants. The concept envisioned is an air-blown pressurized fluidized-bed gasifier followed by a dry hot gas clean...

  10. 16 CFR § 1611.35 - Testing certain classes of fabric and film.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 16 Commercial Practices 2 2013-01-01 2013-01-01 false Testing certain classes of fabric and film... FABRICS ACT REGULATIONS STANDARD FOR THE FLAMMABILITY OF VINYL PLASTIC FILM Rules and Regulations § 1611.35 Testing certain classes of fabric and film. (a) Fabric not customarily washed or dry cleaned. (1...

  11. 9 CFR 318.305 - Equipment and procedures for heat processing systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... control unit. A nonreturn valve shall be provided in the air supply line to prevent water from entering... control unit. A nonreturn valve shall be provided in the air supply line to prevent water from entering... ensure a supply of clean, dry air. The recorder timing mechanism shall be accurate. (i) Chart-type...

  12. JPRS Report, East Europe

    DTIC Science & Technology

    1987-10-29

    nonferrous ores in quarries and underground; Installations for desulfurization , cleaning, and dry- ing of gas , turbocompressors for methane gas ; Mining...Products Exportation Bucharest Minis- "Indus- try of trial- Foreign Drilling installations and equipment for oil and gas ; export- Trade...equipment; try of Refineries, complex installations, parts, and equip- the ment for the oil- and gas -refining industry; Heavy Factories, complex

  13. IMPROVING HUMAN HEALTH RISK ASSESSMENT FOR TETRACHLOROETHENE BY USING BIOMARKERS AND NEUROBEHAVIORAL TESTING IN DIVERSE RESIDENTIAL POPULATIONS

    EPA Science Inventory

    The U.S. EPA considers tetrachloroethene (perc) a problematic pollutant in urban areas. The New York State Department of Health (NYSDOH) has documented high levels of perc in the indoor air of apartments located in the same buildings as dry cleaning facilities in New York Stat...

  14. Evaluation of a Commercial Air Filter for Removal of Virus from the Air

    PubMed Central

    Roelants, P.; Boon, B.; Lhoest, W.

    1968-01-01

    The effectiveness of a commercial absolute air filter for removal of viruses from air was tested with an actinophage, under the usual conditions of a laminar airflow clean room. A new method of dry phage dispersion is described. The filter showed an average reduction of 99.996% of airborne actinophage. PMID:5684200

  15. Keynote address: the role of silviculture in restoring fire-adapted ecosystems

    Treesearch

    James K. Agee

    2007-01-01

    Across the drier forests of the western United States, historical fire was a natural silvicultural process--thinning stands from below, cleaning surface fuels, and maintaining fire-resilient conditions. The 20th century fire exclusion policy, although initiated with the best of intentions, has been a disaster in dry forests, converting them to high-severity fire...

  16. 46 CFR 151.50-34 - Vinyl chloride (vinyl chloride monomer).

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... be used as a “check” on the required closed gauge, nor as a means or sampling. (h) The words “CANCER... legend: cancer—suspect agent in this area protective equipment required authorized personnel only must be... clean and dry for each use, to prevent skin contact with liquid vinyl chloride. [CGFR 70-10, 35 FR 3714...

  17. 46 CFR 151.50-34 - Vinyl chloride (vinyl chloride monomer).

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... be used as a “check” on the required closed gauge, nor as a means or sampling. (h) The words “CANCER... legend: cancer—suspect agent in this area protective equipment required authorized personnel only must be... clean and dry for each use, to prevent skin contact with liquid vinyl chloride. [CGFR 70-10, 35 FR 3714...

  18. 46 CFR 151.50-34 - Vinyl chloride (vinyl chloride monomer).

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... be used as a “check” on the required closed gauge, nor as a means or sampling. (h) The words “CANCER... legend: cancer—suspect agent in this area protective equipment required authorized personnel only must be... clean and dry for each use, to prevent skin contact with liquid vinyl chloride. [CGFR 70-10, 35 FR 3714...

  19. 46 CFR 154.1730 - Ethylene oxide: Loading and off loading.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Ethylene oxide: Loading and off loading. 154.1730... Operating Requirements § 154.1730 Ethylene oxide: Loading and off loading. (a) The master shall ensure that before ethylene oxide is loaded into a cargo tank: (1) The tank is thoroughly clean, dry, and free of...

  20. Method for simultaneous use of a single additive for coal flotation, dewatering, and reconstitution

    DOEpatents

    Wen, Wu-Wey; Gray, McMahan L.; Champagne, Kenneth J.

    1995-01-01

    A single dose of additive contributes to three consecutive fine coal unit operations, i.e., flotation, dewatering and reconstitution, whereby the fine coal is first combined with water in a predetermined proportion so as to formulate a slurry. The slurry is then mixed with a heavy hydrocarbon-based emulsion in a second predetermined proportion and at a first predetermined mixing speed and for a predetermined period of time. The conditioned slurry is then cleaned by a froth flotation method to form a clean coal froth and then the froth is dewatered by vacuum filtration or a centrifugation process to form reconstituted products that are dried to dust-less clumps prior to combustion.

Top